WorldWideScience

Sample records for building technical area

  1. Information support of monitoring of technical condition of buildings in construction risk area

    Science.gov (United States)

    Skachkova, M. E.; Lepihina, O. Y.; Ignatova, V. V.

    2018-05-01

    The paper presents the results of the research devoted to the development of a model of information support of monitoring buildings technical condition; these buildings are located in the construction risk area. As a result of the visual and instrumental survey, as well as the analysis of existing approaches and techniques, attributive and cartographic databases have been created. These databases allow monitoring defects and damages of buildings located in a 30-meter risk area from the object under construction. The classification of structures and defects of these buildings under survey is presented. The functional capabilities of the developed model and the field of it practical applications are determined.

  2. Upgrades and Enclosure of Building 15 at Technical Area 40: Los Alamos National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Plimpton, Kathryn D [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Garcia, Kari L. M [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brunette, Jeremy Christopher [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); McGehee, Ellen D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-15

    The U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office (Field Office) proposes to upgrade and enclose Building 15 at Technical Area (TA) 40, Los Alamos National Laboratory. Building TA-40-15, a Cold War-era firing site, was determined eligible for listing in the National Register of Historic Places (Register) in DX Division’s Facility Strategic Plan: Consolidation and Revitalization at Technical Areas 6, 8, 9, 14, 15, 22, 36, 39, 40, 60, and 69 (McGehee et al. 2005). Building TA-40-15 was constructed in 1950 to support detonator testing. The firing site will be enclosed by a steel building to create a new indoor facility that will allow for year-round mission capability. Enclosing TA-40-15 will adversely affect the building by altering the characteristics that make it eligible for the Register. In compliance with Section 106 of the National Historic Preservation Act of 1966, as amended, the Field Office is initiating consultation for this proposed undertaking. The Field Office is also requesting concurrence with the use of standard practices to resolve adverse effects as defined in the Programmatic Agreement among the U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office, the New Mexico State Historic Preservation Office and the Advisory Council on Historic Preservation Concerning Management of the Historic Properties at Los Alamos National Laboratory, Los Alamos, New Mexico.

  3. Radon Protection in the Technical Building Code

    International Nuclear Information System (INIS)

    Frutos, B.; Garcia, J. P.; Martin, J. L.; Olaya, M.; Serrano, J I.; Suarez, E.; Fernandez, J. A.; Rodrigo, F.

    2003-01-01

    Building construction in areas with high radon gas contamination in land requires the incorporation of certain measures in order to prevent the accumulation of this gas on the inside of buildings. These measures should be considered primarily in the design and construction phases and should take the area of the country into consideration where the construction will take place depending on the potential risk of radon entrance. Within the Technical Building Code, radon protection has been considered through general classification of the country and specific areas where building construction is to take place, in different risk categories and in the introduction of building techniques appropriate for each area. (Author) 17 refs

  4. Final environmental assessment: TRU waste drum staging building, Technical Area 55, Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    1996-01-01

    Much of the US Department of Energy's (DOE's) research on plutonium metallurgy and plutonium processing is performed at Los Alamos National Laboratory (LANL), in Los Alamos, New Mexico. LANL's main facility for plutonium research is the Plutonium Facility, also referred to as Technical Area 55 (TA-55). The main laboratory building for plutonium work within the Plutonium Facility (TA-55) is the Plutonium Facility Building 4, or PF-4. This Environmental Assessment (EA) analyzes the potential environmental effects that would be expected to occur if DOE were to stage sealed containers of transuranic (TRU) and TRU mixed waste in a support building at the Plutonium Facility (TA-55) that is adjacent to PF-4. At present, the waste containers are staged in the basement of PF-4. The proposed project is to convert an existing support structure (Building 185), a prefabricated metal building on a concrete foundation, and operate it as a temporary staging facility for sealed containers of solid TRU and TRU mixed waste. The TRU and TRU mixed wastes would be contained in sealed 55-gallon drums and standard waste boxes as they await approval to be transported to TA-54. The containers would then be transported to a longer term TRU waste storage area at TA-54. The TRU wastes are generated from plutonium operations carried out in PF-4. The drum staging building would also be used to store and prepare for use new, empty TRU waste containers

  5. Earth-covered buildings: technical notes

    Energy Technology Data Exchange (ETDEWEB)

    Moreland, F L; Higgs, F; Shih, J [eds.

    1978-01-01

    John Cable, Architectural and Engineering Systems Branch, Division of Buildings and Community Systems, Department of Energy, kicked off the conference and spelled out the role of DOE in this area. One of his points was that the technical problems are easier than the institutional problems. A separate abstract was prepared for each of the 18 papers of this volume; all of the abstracts will appear in Energy Research Abstracts (ERA), and 16 were selected for Energy Abstractss for Policy Analysis (EAPA). (DCK)

  6. Seismic assessment of Technical Area V (TA-V).

    Energy Technology Data Exchange (ETDEWEB)

    Medrano, Carlos S.

    2014-03-01

    The Technical Area V (TA-V) Seismic Assessment Report was commissioned as part of Sandia National Laboratories (SNL) Self Assessment Requirement per DOE O 414.1, Quality Assurance, for seismic impact on existing facilities at Technical Area-V (TA-V). SNL TA-V facilities are located on an existing Uniform Building Code (UBC) Seismic Zone IIB Site within the physical boundary of the Kirtland Air Force Base (KAFB). The document delineates a summary of the existing facilities with their safety-significant structure, system and components, identifies DOE Guidance, conceptual framework, past assessments and the present Geological and Seismic conditions. Building upon the past information and the evolution of the new seismic design criteria, the document discusses the potential impact of the new standards and provides recommendations based upon the current International Building Code (IBC) per DOE O 420.1B, Facility Safety and DOE G 420.1-2, Guide for the Mitigation of Natural Phenomena Hazards for DOE Nuclear Facilities and Non-Nuclear Facilities.

  7. Building Capacity for Protected Area Management in Lao PDR

    Science.gov (United States)

    Rao, Madhu; Johnson, Arlyne; Spence, Kelly; Sypasong, Ahnsany; Bynum, Nora; Sterling, Eleanor; Phimminith, Thavy; Praxaysombath, Bounthob

    2014-04-01

    Declining biodiversity in protected areas in Laos is attributed to unsustainable exploitation of natural resources. At a basic level, an important need is to develop capacity in academic and professional training institutions to provide relevant training to conservation professionals. The paper (a) describes the capacity building approach undertaken to achieve this goal, (b) evaluates the effectiveness of the approach in building capacity for implementing conservation and (c) reviews implementation outcomes. Strong linkages between organizations implementing field conservation, professional training institutions, and relevant Government agencies are central to enhancing effectiveness of capacity building initiatives aimed at improving the practice of conservation. Protected area management technical capacity needs will need to directly influence curriculum design to insure both relevance and effectiveness of training in improving protected area management. Sustainability of capacity building initiatives is largely dependent on the level of interest and commitment by host-country institutions within a supportive Government policy framework in addition to engagement of organizations implementing conservation.

  8. Community Building Services Training Program: A Model Training Program to Provide Technical Training for Minority Adults in Construction, Building Maintenance,and Property Management. Final Report.

    Science.gov (United States)

    Community Building Maintenance Corp., Chicago, IL.

    A demonstration program, administered by a community based building maintenance, management, and construction corporation, was developed to provide technical training for minority adults in construction, building maintenance, and property management in the Chicago area. The program was concerned with seeking solutions to the lack of housing, job…

  9. Assessment of the Technical Potential for Achieving Net Zero-Energy Buildings in the Commercial Sector

    Energy Technology Data Exchange (ETDEWEB)

    Griffith, B.; Long, N.; Torcellini, P.; Judkoff, R.; Crawley, D.; Ryan, J.

    2007-12-01

    This report summarizes the findings from research conducted at NREL to assess the technical potential for zero-energy building technologies and practices to reduce the impact of commercial buildings on the U.S. energy system. Commercial buildings currently account for 18% of annual U.S. energy consumption, and energy use is growing along with overall floor area. Reducing the energy use of this sector will require aggressive research goals and rapid implementation of the research results.

  10. Technical Support Document: 50% Energy Savings for Small Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, Brian A.; Wang, Weimin; Huang, Yunzhi; Lane, Michael D.; Liu, Bing

    2010-04-30

    The Technical Support Document (TSD) for 50% energy savings in small office buildings documents the analysis and results for a recommended package of energy efficiency measures (EEMs) referred to as the advanced EEMs. These are changes to a building design that will reduce energy usage. The package of advanced EEMs achieves a minimum of 50% energy savings and a construction area weighted average energy savings of 56.6% over the ANSI/ASHRAE/IESNA Standard 90.1-2004 for 16 cities which represent the full range of climate zones in the United States. The 50% goal is for site energy usage reduction. The weighted average is based on data on the building area of construction in the various climate locations. Cost-effectiveness of the EEMs is determined showing an average simple payback of 6.7 years for all 16 climate locations. An alternative set of results is provided which includes a variable air volume HVAC system that achieves at least 50% energy savings in 7 of the 16 climate zones with a construction area weighted average savings of 48.5%. Other packages of EEMs may also achieve 50% energy savings; this report does not consider all alternatives but rather presents at least one way to reach the goal. Design teams using this TSD should follow an integrated design approach and utilize additional analysis to evaluate the specific conditions of a project.

  11. Technical standards in nuclear area

    International Nuclear Information System (INIS)

    Grimberg, M.

    1978-01-01

    The technical standardization in nuclear area is discussed. Also, the competence of CNEN in standardization pursuit is analysed. Moreover, the process of working up of technical standards is explained; in addition, some kinds of technical standards are discussed. (author) [pt

  12. A technical framework to describe occupant behavior for building energy simulations

    Energy Technology Data Exchange (ETDEWEB)

    Turner, William; Hong, Tianzhen

    2013-12-20

    Green buildings that fail to meet expected design performance criteria indicate that technology alone does not guarantee high performance. Human influences are quite often simplified and ignored in the design, construction, and operation of buildings. Energy-conscious human behavior has been demonstrated to be a significant positive factor for improving the indoor environment while reducing the energy use of buildings. In our study we developed a new technical framework to describe energy-related human behavior in buildings. The energy-related behavior includes accounting for individuals and groups of occupants and their interactions with building energy services systems, appliances and facilities. The technical framework consists of four key components: i. the drivers behind energy-related occupant behavior, which are biological, societal, environmental, physical, and economical in nature ii. the needs of the occupants are based on satisfying criteria that are either physical (e.g. thermal, visual and acoustic comfort) or non-physical (e.g. entertainment, privacy, and social reward) iii. the actions that building occupants perform when their needs are not fulfilled iv. the systems with which an occupant can interact to satisfy their needs The technical framework aims to provide a standardized description of a complete set of human energy-related behaviors in the form of an XML schema. For each type of behavior (e.g., occupants opening/closing windows, switching on/off lights etc.) we identify a set of common behaviors based on a literature review, survey data, and our own field study and analysis. Stochastic models are adopted or developed for each type of behavior to enable the evaluation of the impact of human behavior on energy use in buildings, during either the design or operation phase. We will also demonstrate the use of the technical framework in assessing the impact of occupancy behavior on energy saving technologies. The technical framework presented is

  13. Possibilities of Use of UAVS for Technical Inspection of Buildings and Constructions

    Science.gov (United States)

    Banaszek, Anna; Banaszek, Sebastian; Cellmer, Anna

    2017-12-01

    In recent years, Unmanned Aerial Vehicles (UAVs) have been used in various sectors of the economy. This is due to the development of new technologies for acquiring and processing geospatial data. The paper presents the results of experiments using UAV, equipped with a high resolution digital camera, for a visual assessment of the technical condition of the building roof and for the inventory of energy infrastructure and its surroundings. The usefulness of digital images obtained from the UAV deck is presented in concrete examples. The use of UAV offers new opportunities in the area of technical inspection due to the detail and accuracy of the data, low operating costs and fast data acquisition.

  14. Training and technical assistance to enhance capacity building between prevention research centers and their partners.

    Science.gov (United States)

    Spadaro, Antonia J; Grunbaum, Jo Anne; Dawkins, Nicola U; Wright, Demia S; Rubel, Stephanie K; Green, Diane C; Simoes, Eduardo J

    2011-05-01

    The Centers for Disease Control and Prevention has administered the Prevention Research Centers Program since 1986. We quantified the number and reach of training programs across all centers, determined whether the centers' outcomes varied by characteristics of the academic institution, and explored potential benefits of training and technical assistance for academic researchers and community partners. We characterized how these activities enhanced capacity building within Prevention Research Centers and the community. The program office collected quantitative information on training across all 33 centers via its Internet-based system from April through December 2007. Qualitative data were collected from April through May 2007. We selected 9 centers each for 2 separate, semistructured, telephone interviews, 1 on training and 1 on technical assistance. Across 24 centers, 4,777 people were trained in 99 training programs in fiscal year 2007 (October 1, 2006-September 30, 2007). Nearly 30% of people trained were community members or agency representatives. Training and technical assistance activities provided opportunities to enhance community partners' capacity in areas such as conducting needs assessments and writing grants and to improve the centers' capacity for cultural competency. Both qualitative and quantitative data demonstrated that training and technical assistance activities can foster capacity building and provide a reciprocal venue to support researchers' and the community's research interests. Future evaluation could assess community and public health partners' perception of centers' training programs and technical assistance.

  15. Commercial Building Energy Asset Score Program Overview and Technical Protocol (Version 1.1)

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Na; Goel, Supriya; Makhmalbaf, Atefe

    2013-08-09

    The U.S. Department of Energy (DOE) is developing a voluntary national scoring system for commercial buildings to help building owners and managers assess a building’s energy-related systems independent of operations. The goal of the score is to facilitate cost-effective investment in energy efficiency improvements of commercial buildings. The system, known as the Commercial Building Energy Asset Score, will allow building owners and managers to compare their building infrastructure against peers and track building upgrades over time. The system will also help other building stakeholders (e.g., building investors, tenants, financiers, and appraisers) understand the relative efficiency of different buildings in a way that is independent from operations and occupancy. This report outlines the technical protocol used to generate the energy asset score, explains the scoring methodology, and provides additional details regarding the energy asset scoring tool. The alternative methods that were considered prior to developing the current approach are described in the Program Overview and Technical Protocol Version 1.0.

  16. Technical - Economic Research for Passive Buildings

    Science.gov (United States)

    Miniotaite, Ruta

    2017-10-01

    A newly constructed passive house must save 80 % of heat resources; otherwise it is not a passive house. The heating energy demand of a passive building is less than 15 kWh/m2 per year. However, a passive house is something more than just an energy-saving house. This concept involves sustainable, high-quality, valuable, healthy and durable construction. Features of a passive house: high insulation of envelope components, high-quality windows, good tightness of the building, regenerative ventilation system and elimination of thermal bridges. The Energy Performance of Buildings Directive (EPBD) 61 requires all new public buildings to become near-zero energy buildings by 2019 and will be extended to all new buildings by 2021. This concept involves sustainable, high-quality, valuable, healthy and durable construction. Foundation, walls and roofs are the most essential elements of a house. The type of foundation for a private house is selected considering many factors. The article examines technological and structural solutions for passive buildings foundation, walls and roofs. The technical-economic comparison of the main structures of a passive house revealed that it is cheaper to install an adequately designed concrete slab foundation than to build strip or pile foundation and the floor separately. Timber stud walls are the cheapest wall option for a passive house and 45-51% cheaper compared to other options. The comparison of roofs and ceilings showed that insulation of the ceiling is 25% more efficient than insulation of the roof. The comparison of the main envelope elements efficiency by multiple-criteria evaluation methods showed that it is economically feasible to install concrete slab on ground foundation, stud walls with sheet cladding and a pitched roof with insulated ceiling.

  17. Building a 'data repository' for heterogenous technical research communities through collaborations

    NARCIS (Netherlands)

    Rombouts, J.; Princic, A.

    2010-01-01

    The paper describes the project ‘3TU.Datacentrum’, an initiative of the libraries of the three Dutch Technical Universities. Its aim is to build a data curation facility for the improvement of data management, providing data curation services for data producers of the Technical Universities and

  18. U Plant Aggregate Area Management study technical baseline report

    International Nuclear Information System (INIS)

    DeFord, D.H.; Carpenter, R.W.

    1995-05-01

    This document was prepared in support of an Aggregate Area Management Study of U Plant. It provides a technical baseline of the aggregate area and results from an environmental investigation that was undertaken by the Technical Baseline Section of the Environmental Engineering Group, Westinghouse Hanford Company (WHC), which is currently the Waste Site and Facility Research Office, Natural Resources, Bechtel Hanford, Inc. (BHI). It is based upon review and evaluation of numerous Hanford Site current and historical reports, drawings and photographs, supplemented with site inspections and employee interviews. U Plant refers to the 221-U Process Canyon Building, a chemical separation facility constructed during World War II. It also includes the Uranium Oxide (UO 3 ) Plant constructed at the same time as 221-U as an adjunct to the original plutonium separation process but which, like 221-U, was converted for other missions. Waste sites are associated primarily with U Plant's 1952 through 1958 Uranium Metal Recovery Program mission and the U0 3 Plant's ongoing U0 3 mission. Waste sites include cribs, reverse wells, french drains, septic tanks and drain fields, trenches, catch tanks, settling tanks, diversion boxes, a waste vault, and the lines and encasements that connect them. It also includes the U Pond and its feed ditches and an underground tank farm designed for high-level liquid wastes

  19. Estimation of the excess lifetime cancer risk from radon exposure in some buildings of Kufa Technical Institute, Iraq

    Directory of Open Access Journals (Sweden)

    Ali Abid Abojassim

    2017-12-01

    Full Text Available A number of international health organizations consider the exposure to residential radon as the second main cause of lung cancer after cigarette smoking. It was found that there is no database on radon concentrations for the Kufa Technical Institute buildings in the literature. This therefore triggers a special need for radon measurement in some Kufa Technical Institute buildings. This study aims to investigate the indoor radon levels inside the Kufa Technical Institute buildings for the first time using different radon measurement methods such as active (RAD-7 and passive (LR-115 Type II methods. Seventy eight of Solid-State Nuclear Track Detectors (SSNTDs LR-115 Type II were distributed at four buildings within the study area. The LR-115 Type II detectors were exposed in the study area for three months period. In parallel to the latter, seventy two active measurements were conducted using RAD-7 in the same buildings for correlation investigation purposes between the two kinds of measurements (i.e. passive and active.The results demonstrate that the radon concentrations were generally low, ranging from 38.4 to 77.2 Bq/m3, with a mean value of 50 Bq/m3. The mean of the equilibrium equivalent radon concentration and annual effective dose were assessed to be 19.9 Bq/m3 and 1.2 mS/y, respectively; the excess lifetime lung cancer risk was approximately 11.6 per million personal. A high correlation was found between the methods of measurements (i.e. LR-115 Type II and RAD-7, R2 = 0.99 which is significant at P < 0.001. The results of this work revealed that the Radon concentration was below the action level set by the United States Environmental Protection Agency of 148 Bq/m3. This therefore indicates that no radiological health hazard exists. However, the relatively high concentrations in some classrooms can be addressed by the natural ventilation or the classrooms being supplied with suction fans.

  20. Optimal technical and economic strategy for retrofitting residential buildings in Romania

    Directory of Open Access Journals (Sweden)

    Căruțașiu Mihail-Bogdan

    2017-07-01

    Full Text Available The European Legislation is very strict regarding the importance of reducing the energy consumption in buildings sector. The importance of achieving nearly zero energy consumption levels for both new and existing buildings is also highlighted in each Members’ national legislation. Moreover, the high percentage of existing buildings across European Union, indicates that they need to be adequately approached in order to achieve the ambitious energy efficiency goals. This implies creating the optimal technical and financial retrofit strategies regarding minimizing the energy consumption without lowering the interior comfort levels. In Romania, there is no unitary strategy aiming to maximize the energy efficiency in buildings which also takes into consideration the financial part of the process. Moreover, there are no known national guidelines and strategies for buildings retrofit which takes into consideration a wide range of equipment. The Romanian Energy Efficiency Strategy presents few possibilities resulted from integrating renewable energy sources within typical Romanian buildings, while the Buildings Performance Institute Europe conducted a research regarding the potential of nearly Zero Energy Buildings implementation across Romanian territory. Both studies refer only to typical buildings and do not present a large perspective for retrofitting action, while the financial study is not properly presented. Thus, this paper develops a comprehensive financial study which could be used as guideline by stakeholders, in order to find the best technical solution for decreasing the final energy consumption in Romanian residential buildings. Using the RETScreen software and its economical features, there were developed several energy efficiency solutions, and by analyzing the financial benefits implied, the best solution was chosen. By adopting the solutions presented within this feasibility study, the energy consumption of buildings should be

  1. Exploring Socio-Technical Features of Green Interior Design of Residential Buildings: Indicators, Interdependence and Embeddedness

    Directory of Open Access Journals (Sweden)

    Yan Ning

    2016-12-01

    Full Text Available This research aims to develop indicators for assessing green interior design of new residential buildings in China, grounded in the socio-technical systems approach. The research was carried out through a critical literature review and two focus group studies. The results show that the boundaries of green interior design were identified with respect to three dimensions, namely performance, methodology and stakeholders. The socio-technical systems approach argues for the recognition of the interdependence between the systems elements and the feature of embeddedness. The interdependence of the systems elements exists within each of these three dimensions and across them. It is also found that the socio-technical systems of green interior design are embedded in the social, regulatory and geographic context. Taking interior design of residential buildings as the empirical setting, this study contributes to the literature of green building assessment by presenting a socio-technical systems approach.

  2. Technical definition for nearly zero energy buildings nZEB

    DEFF Research Database (Denmark)

    Kurnitski, Jarek; Allard, Francis; Braham, Derrick

    or maximum harmonized requirements as well as details of energy performance calculation framework, it will be up to the Member States to define what these for them exactly constitute. In the definition local conditions are to be obviously taken into account, but the uniform methodology can be used in all......This REHVA Task Force proposes a technical definition for nearly zero energy buildings required in the implementation of the Energy performance of buildings directive recast. Energy calculation framework and system boundaries associated with the definition are provided to specify which energy flows...... in which way are taken into account in the energy performance assessment. The intention of the Task Force is to help the experts in the Member States in defining the nearly zero energy buildings in a uniform way. The directive requires nearly zero energy buildings, but since it does not give minimum...

  3. Technical Support Document: Strategies for 50% Energy Savings in Large Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Leach, M.; Lobato, C.; Hirsch, A.; Pless, S.; Torcellini, P.

    2010-09-01

    This Technical Support Document (TSD) documents technical analysis that informs design guidance for designing and constructing large office buildings that achieve 50% net site energy savings over baseline buildings defined by minimal compliance with respect to ANSI/ASHRAE/IESNA Standard 90.1-2004. This report also represents a step toward developing a methodology for using energy modeling in the design process to achieve aggressive energy savings targets. This report documents the modeling and analysis methods used to identify design recommendations for six climate zones that capture the range of U.S. climate variability; demonstrates how energy savings change between ASHRAE Standard 90.1-2007 and Standard 90.1-2004 to determine baseline energy use; uses a four-story 'low-rise' prototype to analyze the effect of building aspect ratio on energy use intensity; explores comparisons between baseline and low-energy building energy use for alternate energy metrics (net source energy, energy emissions, and energy cost); and examines the extent to which glass curtain construction limits achieve energy savings by using a 12-story 'high-rise' prototype.

  4. Technical Support Document: 50% Energy Savings Design Technology Packages for Highway Lodging Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Wei; Gowri, Krishnan; Lane, Michael D.; Thornton, Brian A.; Rosenberg, Michael I.; Liu, Bing

    2009-09-28

    This Technical Support Document (TSD) describes the process, methodology and assumptions for development of the 50% Energy Savings Design Technology Packages for Highway Lodging Buildings, a design guidance document intended to provide recommendations for achieving 50% energy savings in highway lodging properties over the energy-efficiency levels contained in ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings.

  5. Technical Support Document: 50% Energy Savings Design Technology Packages for Medium Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, Brian A.; Wang, Weimin; Lane, Michael D.; Rosenberg, Michael I.; Liu, Bing

    2009-09-01

    This Technical Support Document (TSD) describes the process and methodology for development of the Advanced Energy Design Guide for Medium Offices (AEDG-MO or the Guide), a design guidance document which intends to provide recommendations for achieving 50% energy savings in medium office buildings that just meet the requirements of ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings.

  6. Sustainable Buildings in Interaction

    DEFF Research Database (Denmark)

    Elle, Morten

    2007-01-01

    The first attempts to build sustainable buildings in Denmark were typically located on the countryside. The basic idea was to create buildings that were independent of the technical infrastructure. District heating has, however, been the dominating solution to heating in buildings in Denmark......, and the focus on sustainable building have gradually turned from special houses on the countryside to normally looking houses in the urban fabric, integrated in the technical infrastructure. Some new built urban areas in Denmark will, however, not have to be supplied with district heating – these developments...... are going to consist of passive houses. The first sustainable buildings were built by their users, and the user – building interaction still play a decisive role for the performance of the present sustainable buildings. The users have to understand how the building functions. Urban design is essential...

  7. Rooftop Solar Photovoltaic Technical Potential in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Pieter; Margolis, Robert; Melius, Jennifer; Phillips, Caleb; Elmore, Ryan

    2016-01-01

    How much energy could we generate if PV modules were installed on all of the suitable roof area in the nation? To answer this question, we first use GIS methods to process a lidar dataset and determine the amount of roof area that is suitable for PV deployment in 128 cities nationwide, containing 23% of U.S. buildings, and provide PV-generation results for a subset of those cities. We then extend the insights from that analysis to the entire continental United States. We develop two statistical models -- one for small buildings and one for medium and large buildings -- and populate them with geographic variables that correlate with rooftop's suitability for PV. We simulate the productivity of PV installed on the suitable roof area, and present the technical potential of PV on both small buildings and medium/large buildings for every state in the continental US. Within the 128 cities covered by lidar data, 83% of small buildings have a location suitable for a PV installation, but only 26% of the total rooftop area of small buildings is suitable for development. The sheer number of buildings in this class, however, gives small buildings the greatest technical potential. Small building rooftops could accommodate 731 GW of PV capacity and generate 926 TWh/year of PV energy, approximately 65% of rooftop PV's total technical potential. We conclude by summing the PV-generation results for all building sizes and therefore answering our original question, estimating that the total national technical potential of rooftop PV is 1,118 GW of installed capacity and 1,432 TWh of annual energy generation. This equates to 39% of total national electric-sector sales.

  8. Large-scale building integrated photovoltaics field trial. First technical report - installation phase

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    This report summarises the results of the first eighteen months of the Large-Scale Building Integrated Photovoltaic Field Trial focussing on technical aspects. The project aims included increasing awareness and application of the technology, raising the UK capabilities in application of the technology, and assessing the potential for building integrated photovoltaics (BIPV). Details are given of technology choices; project organisation, cost, and status; and the evaluation criteria. Installations of BIPV described include University buildings, commercial centres, and a sports stadium, wildlife park, church hall, and district council building. Lessons learnt are discussed, and a further report covering monitoring aspects is planned.

  9. Low Energy Accelerator Laboratory Technical Area 53, Los Alamos National Laboratory. Environmental assessment

    International Nuclear Information System (INIS)

    1995-04-01

    This Environmental Assessment (EA) analyzes the potential environmental impacts that would be expected to occur if the Department of Energy (DOE) were to construct and operate a small research and development laboratory building at Technical Area (TA) 53 at the Los Alamos National Laboratory (LANL), Los Alamos, New Mexico. DOE proposes to construct a small building to be called the Low Energy Accelerator Laboratory (LEAL), at a previously cleared, bladed, and leveled quarter-acre site next to other facilities housing linear accelerator research activities at TA-53. Operations proposed for LEAL would consist of bench-scale research, development, and testing of the initial section of linear particle accelerators. This initial section consists of various components that are collectively called an injector system. The anticipated life span of the proposed development program would be about 15 years

  10. Right, laws, regulations and technical building systems; Recht, Gesetze, Verordnungen und Technische Gebaeudesysteme

    Energy Technology Data Exchange (ETDEWEB)

    Kranz, H.R. [Siemens AG, Karlsruhe (Germany)

    1995-12-31

    Chapter 23 of the anthology about building control gives an overview of the laws and regulations in the field of technical building systems. The following fields are discussed: license regulations in the field of building trade, communication law, environmental responsibility law, building right, European directives, laws and regulations of the Federal Government and the Laender. (BWI) [Deutsch] Kapitel 23 des Sammelbandes ueber Building Control gibt einen Ueberblick ueber Recht, Gesetze und Verordnungen im Bereich der Technischen Gebaeudesysteme. In diesem Zusammenhang kommen folgende Bereiche in Frage: Lizenzrecht im Bauwesen; Fernmelderecht; Umwelthaftungsgesetz; Baurecht; Europaeische Richtlinien; Gesetze und Verordnungen des Bundes und der Laender. (BWI)

  11. Learning from Abruzzo earthquake buildings behaviour seen from the Building According-to-the-book perspectives

    International Nuclear Information System (INIS)

    Bazurro, P.; Benedettini, F.; Clemente, P.; Salvatori, A.

    2009-01-01

    A brief description, with the related photographs, is reported on the effects of the recent Abruzzo earthquake on buildings, particularly reinforced-concrete and masonry buildings. Following an overview of the technical building codes particularly focused on the area of L'Aquila, mention is made of cultural heritage structures. [it

  12. Communication of technical building systems. Fundamentals; Kommunikation technischer Gebaeudesysteme. Grundlagen

    Energy Technology Data Exchange (ETDEWEB)

    Kranz, H.R. [Siemens AG, Karlsruhe (Germany)

    1995-12-31

    In chapter 17 of the anthology about building control the communication between and with technical building systems is described. The following aspects are discussed: From the matrix cable to the standard bus, data transmission, communication terms, components of communication systems, type of data transmission, types of connection, networks, protocols, the ISO/OSI reference model, application of automation in the field of communication, services and profiles, communication objects. (BWI) [Deutsch] Kapitel 17 des Sammelbandes ueber Building Control ist dem Thema der Kommunikation zwischen und mit technischen Gebaeudesystemen gewidmet. In diesem Zusammenhang werden folgende Themen angesprochen: Vom Matrixkabel zum Standard-Bus; Daten-Transport; Kommunikations-Begriffe; Komponenten der Kommunikations-Systeme; Art der Datenuebertragung; Verbindungsarten, Netze, Protokolle; Das ISO/OSI Referenzmodell; Automation als Anwendung in der Kommunikation; Dienste und Profile; Kommunikationsobjekte. (BWI)

  13. Factors Influencing Choice of Occupational Area among Technical ...

    African Journals Online (AJOL)

    Interest in study area; perceived availability of job opportunities related to area of specialization; simplicity of area in training and in employment; and perceived affordability of equipment for self-employment were found to influence choice of occupational area among the two groups. Keywords: Technical Education; Career ...

  14. Design of a multipurpose “zero energy consumption” building according to European Directive 2010/31/EU: Architectural and technical plants solutions

    International Nuclear Information System (INIS)

    Desideri, Umberto; Arcioni, Livia; Leonardi, Daniela; Cesaretti, Luca; Perugini, Perla; Agabitini, Elena; Evangelisti, Nicola

    2013-01-01

    Considering the significant impact that the residential sector has on energy consumption, it is particularly important to implement policies aimed at improving energy efficiency in buildings. Highly energy efficient buildings can either save primary energy or disseminate the use of the most suitable technologies to be used in new constructions. Due to those reasons, the Municipality of Città della Pieve promoted the creation of a “Renewable Energy Park” in a deprived area of its territory, where some green technologies could be installed and tested. This site has also been considered as an optimal location for an educational/demonstrative “zero energy consumption” building for multifunctional activities and realized with the most innovative techniques to save energy. The building may be considered as an example to study and optimize the benefits of higher energy efficiency together with the use of renewable energy systems. In this paper the technical solutions adopted both in the building envelope and the technical plants are described and discussed. A simulation of the behaviour of the building in summer and winter was carried out in order to assess the benefits that can be obtained both in energetic and economic terms. - Highlights: • Project focused on the implementation of European Directive 2010/31/EU. • Energy efficiency in buildings for saving primary energy using renewable sources. • Dissemination of the concept of sustainable development for new buildings. • High performance construction layers and high efficiency plants. • Design of a “zero energy consumption” building with zero emissions of CO 2

  15. Method for building a nuclear power plant and layout thereof

    International Nuclear Information System (INIS)

    Matsuura, Tadashi; Ushiroda, Kouchi; Tajiri, Akinori; Yoshida, Naoto; Takeda, Masakado; Makita, Tasuo; Maezawa, Sumito; Yoshizaki, Masatoshi.

    1997-01-01

    The present invention relates to a technical field of building a nuclear power plant, and its technical issue is to reduce the scale of investment for cranes to be used in building a plurality of nuclear power plant units. In order to resolve the technical issue, in the present invention, a nuclear power plant building method is employed in building a plurality of nuclear plant units in which while an earlier building unit out of the plurality of units which is started to be built earlier is being built, a later building unit that is to be started to be built later than the earlier building unit is started to be built, and in which a common mobile crane is adapted to move between a crane operating area for the earlier building unit and a crane operating area for the later building unit so that the common mobile crane ban be used in building the plurality of units. The present invention is primarily intended for the construction of a nuclear power plant. (author) figs

  16. Simulation of thermal indoor climate in buildings by using human Projected Area Factors

    DEFF Research Database (Denmark)

    Christensen, Jørgen Erik

    2009-01-01

    Nowadays many new and old buildings in Denmark have large glass surfaces. This is a consequence of the technical development of windows with low U-values that has made it possible to build houses with windows from floor to ceiling in northern climates. On the other hand if one is sitting close to...... for dynamic building thermal analysis. The method is demonstrated in a newer apartment with windows from floor to ceiling and shows how impotent it is to include the radiant effect from the glass sur-faces and how it influences the indoor thermal climate significantly.......Nowadays many new and old buildings in Denmark have large glass surfaces. This is a consequence of the technical development of windows with low U-values that has made it possible to build houses with windows from floor to ceiling in northern climates. On the other hand if one is sitting close...

  17. Tech Area II: A history

    Energy Technology Data Exchange (ETDEWEB)

    Ullrich, R. [Ktech Corp., Albuquerque, NM (United States)

    1998-07-01

    This report documents the history of the major buildings in Sandia National Laboratories` Technical Area II. It was prepared in support of the Department of Energy`s compliance with Section 106 of the National Historic Preservation Act. Technical Area II was designed and constructed in 1948 specifically for the final assembly of the non-nuclear components of nuclear weapons, and was the primary site conducting such assembly until 1952. Both the architecture and location of the oldest buildings in the area reflect their original purpose. Assembly activities continued in Area II from 1952 to 1957, but the major responsibility for this work shifted to other sites in the Atomic Energy Commission`s integrated contractor complex. Gradually, additional buildings were constructed and the original buildings were modified. After 1960, the Area`s primary purpose was the research and testing of high-explosive components for nuclear weapons. In 1994, Sandia constructed new facilities for work on high-explosive components outside of the original Area II diamond-shaped parcel. Most of the buildings in the area are vacant and Sandia has no plans to use them. They are proposed for decontamination and demolition as funding becomes available.

  18. 20 CFR 628.325 - Incentive grants, capacity building, and technical assistance.

    Science.gov (United States)

    2010-04-01

    ... capacity building and technical assistance efforts aimed at improving the competencies of the personnel who... developed with funds under this section are made available to be shared with other States, SDA's and the... contributing to the National Network. (2) All shared costs shall be allocated among the contributing funding...

  19. A District Approach to Building Renovation for the Integral Energy Redevelopment of Existing Residential Areas

    Directory of Open Access Journals (Sweden)

    Mira Conci

    2017-05-01

    Full Text Available Building energy renovation quotas are not currently being met due to unfavorable conditions such as complex building regulations, limited investment incentives, historical preservation priorities, and technical limitations. The traditional strategy has been to incrementally lower the energy consumption of the building stock, instead of raising the efficiency of the energy supply through a broader use of renewable sources. This strategy requires an integral redefinition of the approach to energy building renovations. The joint project SWIVT elaborates on a district redevelopment strategy that combines a reduction in the energy demand of existing buildings and their physical interconnection within a local micro-grid and heating network. The district is equipped with energy generation and distribution technologies as well as hybrid thermal and electrical energy storage systems, steered by an optimizing energy management controller. This strategy is explored through three scenarios designed for an existing residential area in Darmstadt, Germany, and benchmarked against measured data. Presented findings show that a total primary energy balance at least 30% lower than that of a standard building renovation can be achieved by a cluster of buildings with different thermal qualities and connected energy generation, conversion, and storage systems, with only minimal physical intervention to existing buildings.

  20. Net-Zero Energy Technical Shelter

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per; Jensen, Rasmus Lund

    2014-01-01

    Technical shelters are the basic structures for storing electronic and technical equipment, and commonly used for telecommunication base station, windmill, gas station, etc. Due to their high internal heat load density and special operation schedule, they consume more energy than normal residential...... or commercial buildings. On the other hand, it is a big challenge to power the technical shelter in remote area where the grids are either not available or the expansion of grid is expensive. In order to minimize the energy consumption and obtain a reliable and cost-efficient power solution for technical...... shelter, this study will apply the net-zero energy concept into the technical shelter design. The energy conservation can be achieved by proper design of building envelop and optimization of the cooling strategies. Both experiments and numerical simulations are carried out to investigate the indoor...

  1. Impact of the buildings areas on the fire incidence.

    Science.gov (United States)

    Srekl, Jože; Golob, Janvit

    2010-03-01

    A survey of statistical studies shows that probability of fires is expressed by the equation P(A) = KAα, where A = total floor area of the building and K and  are constants for an individual group, or risk category. This equation, which is based on the statistical data on fires in Great Britain, does not include the impact factors such as the number of employees and the activities carried out in these buildings. In order to find out possible correlations between the activities carried out in buildings, the characteristics of buildings and number of fires, we used a random sample which included 134 buildings as industrial objects, hotels, restaurants, warehouses and shopping malls. Our study shows that the floor area of buildings has low impact on the incidence of fires. After analysing the sample of buildings by using multivariate analysis we proved a correlation between the number of fires, floor area of objects, work operation period (per day) and the number of employees in objects.

  2. A socio-technical system framework for risk-informed performance-based building regulation

    NARCIS (Netherlands)

    Meacham, B.J.; Straalen, IJ.J. van

    2017-01-01

    Building regulatory systems have been evolving in recent decades, first with a transition to a functional or performance basis, and more recently with the introduction of new societal objectives, including those related to sustainability and climate change resiliency. Various policy and technical

  3. Segmentation of Shadowed Buildings in Dense Urban Areas from Aerial Photographs

    OpenAIRE

    Susaki, Junichi

    2012-01-01

    Segmentation of buildings in urban areas, especially dense urban areas, by using remotely sensed images is highly desirable. However, segmentation results obtained by using existing algorithms are unsatisfactory because of the unclear boundaries between buildings and the shadows cast by neighboring buildings. In this paper, an algorithm is proposed that successfully segments buildings from aerial photographs, including shadowed buildings in dense urban areas. To handle roofs having rough text...

  4. Rooftop Solar Photovoltaic Technical Potential in the United States. A Detailed Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Pieter [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States); Melius, Jennifer [National Renewable Energy Lab. (NREL), Golden, CO (United States); Phillips, Caleb [National Renewable Energy Lab. (NREL), Golden, CO (United States); Elmore, Ryan [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-01-01

    How much energy could be generated if PV modules were installed on all of the suitable roof area in the nation? To answer this question, we first use GIS methods to process a lidar dataset and determine the amount of roof area that is suitable for PV deployment in 128 cities nationwide, containing 23% of U.S. buildings, and provide PV-generation results for a subset of those cities. We then extend the insights from that analysis to the entire continental United States. We develop two statistical models--one for small buildings and one for medium and large buildings--and populate them with geographic variables that correlate with rooftop's suitability for PV. We simulate the productivity of PV installed on the suitable roof area, and present the technical potential of PV on both small buildings and medium/large buildings for every state in the continental US. Within the 128 cities covered by lidar data, 83% of small buildings have a location suitable for a PV installation, but only 26% of the total rooftop area of small buildings is suitable for development. The sheer number of buildings in this class, however, gives small buildings the greatest technical potential. Small building rooftops could accommodate 731 GW of PV capacity and generate 926 TWh/year of PV energy, approximately 65% of rooftop PV's total technical potential. We conclude by summing the PV-generation results for all building sizes and therefore answering our original question, estimating that the total national technical potential of rooftop PV is 1,118 GW of installed capacity and 1,432 TWh of annual energy generation. This equates to 39% of total national electric-sector sales.

  5. 324 Building radiochemical engineering cells, high-level vault, low-level vault, and associated areas closure plan

    International Nuclear Information System (INIS)

    Barnett, J.M.

    1998-01-01

    The Hanford Site, located adjacent to and north of Richland, Washington, is operated by the US Department of Energy, Richland Operations Office (RL). The 324 Building is located in the 300 Area of the Hanford Site. The 324 Building was constructed in the 1960s to support materials and chemical process research and development activities ranging from laboratory/bench-scale studies to full engineering-scale pilot plant demonstrations. In the mid-1990s, it was determined that dangerous waste and waste residues were being stored for greater than 90 days in the 324 Building Radiochemical Engineering Cells (REC) and in the High-Level Vault/Low-Level Vault (HLV/LLV) tanks. [These areas are not Resource Conservation and Recovery Act of 1976 (RCRA) permitted portions of the 324 Building.] Through the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) Milestone M-89, agreement was reached to close the nonpermitted RCRA unit in the 324 Building. This closure plan, managed under TPA Milestone M-20-55, addresses the identified building areas targeted by the Tri-Party Agreement and provides commitments to achieve the highest degree of compliance practicable, given the special technical difficulties of managing mixed waste that contains high-activity radioactive materials, and the physical limitations of working remotely in the areas within the subject closure unit. This closure plan is divided into nine chapters. Chapter 1.0 provides the introduction, historical perspective, 324 Building history and current mission, and the regulatory basis and strategy for managing the closure unit. Chapters 2.0, 3.0, 4.0, and 5.0 discuss the detailed facility description, process information, waste characteristics, and groundwater monitoring respectively. Chapter 6.0 deals with the closure strategy and performance standard, including the closure activities for the B-Cell, D-Cell, HLV, LLV; piping and miscellaneous associated building areas. Chapter 7.0 addresses the

  6. MINIMUM AREAS FOR ELEMENTARY SCHOOL BUILDING FACILITIES.

    Science.gov (United States)

    Pennsylvania State Dept. of Public Instruction, Harrisburg.

    MINIMUM AREA SPACE REQUIREMENTS IN SQUARE FOOTAGE FOR ELEMENTARY SCHOOL BUILDING FACILITIES ARE PRESENTED, INCLUDING FACILITIES FOR INSTRUCTIONAL USE, GENERAL USE, AND SERVICE USE. LIBRARY, CAFETERIA, KITCHEN, STORAGE, AND MULTIPURPOSE ROOMS SHOULD BE SIZED FOR THE PROJECTED ENROLLMENT OF THE BUILDING IN ACCORDANCE WITH THE PROJECTION UNDER THE…

  7. Small Buildings in Earthquake Areas. Educational Building Digest 2.

    Science.gov (United States)

    Mooij, D.

    This booklet is intended for builders and others who actually construct small buildings in earthquake areas and not for professionally qualified architects or engineers. In outline form with sketches the following topics are discussed: general construction and design principles; foundations; earth walls; brick, block, and stone walls; timber frame…

  8. The Influence of the Technical Condition of a Building on the Property’s Market Value

    Directory of Open Access Journals (Sweden)

    Ziembicka Beata

    2016-12-01

    Full Text Available The housed property’s market value is influenced by a set of characteristic qualities, among which is the technical condition of a building. The aim of this paper is to study the influence of the technical condition of a building on the market price of the dwelling units, depending, among others, on the chosen method and the approach to the assessment of the housing wear degree. The analysis has been performed based on the estimation of the market value of an illustrative dwelling unit located in a building erected with the use of prefabricated large panel technology in selected variants. The study is based on data from the period between January and December 2012, which are related to the sale of rights to dwelling units from the secondary market. The information was obtained from a transactional database based on the Partner Data Exchange system with the Walor software.

  9. The methodology of technical due diligence report preparation for an office, residential and industrial buildings

    Directory of Open Access Journals (Sweden)

    Kutera Beata

    2016-01-01

    Full Text Available The methodology of a technical due diligence preparation is presented in this paper. It comprises actions that have to be undertaken prior to formal agreement with party ordering due diligence preparation, building a team of consultants, data collecting, preparing analysis and handing over the report to the client. All important issues were described and supported by examples. As there are many types of building objects this paper is limited to office, residential and industrial buildings.

  10. The roots of gender inequity in technical areas

    Science.gov (United States)

    Campbell, James Reed

    This article describes a study of the academic self-concepts, attributions and achievements of male and female Asian American and Caucasian students who won Westinghouse Awards in 1984 and 1985. The results of the study showed that fewer Caucasian female recipients anticipated college majors in the technical areas. Furthermore, this group of females scored lower on both parts of the SAT, scored lower on all of the self-concept scales, and also scored lower on both attribution scales. In contrast, the Asian females optimized courses for the gifted and specialized research courses to distance themselves from the American females in almost all areas. The author linked these ethnic, gender differences to underlying psychological and sociological forces that are responsible for the self-concept and attribution differences. It is these forces that must be altered for Caucasian females to rectify the gender inequalities that exist in the technical areas.

  11. Areas and programmes of technical assistance

    International Nuclear Information System (INIS)

    1998-01-01

    The cooperation between the Atomic Energy Commission of Costa Rica, and the International Atomic Energy Agency, has permitted to carry out programmes and projects which agree with the national objectives of development. In the areas of environmental hydrology; physical sciences and chemistry; industry and geological sciences; health and animal production; biological sciences, agriculture and alimentation; scientific and technical information. (author) [es

  12. BizWatts: A modular socio-technical energy management system for empowering commercial building occupants to conserve energy

    International Nuclear Information System (INIS)

    Gulbinas, R.; Jain, R.K.; Taylor, J.E.

    2014-01-01

    Highlights: • We developed a socio-technical commercial building energy management system. • It was designed for directly engaging and connecting building occupants via feedback. • We collected an array of clickstream data for internal design validation. • A pilot study validated its ability to drive energy savings in commercial buildings. - Abstract: Commercial buildings represent a significant portion of energy consumption and environmental emissions worldwide. To help mitigate the environmental impact of building operations, building energy management systems and behavior-based campaigns designed to reduce energy consumption are becoming increasingly popular. In this paper, we describe the development of a modular socio-technical energy management system, BizWatts, which combines the two approaches by providing real-time, appliance-level power management and socially contextualized energy consumption feedback. We describe in detail the physical and virtual architecture of the system, which simultaneously engages building occupants and facility managers, as well as the main principles behind the interface design and component functionalities. A discussion about how the data collection capabilities of the system enable insightful commercial building energy efficiency studies and quantitative network analysis is also included. We conclude by commenting on the validation of the system, identifying current system limitations and introducing new research avenues that the development and deployment of BizWatts enables

  13. Tanks Focus Area FY98 midyear technical review

    Energy Technology Data Exchange (ETDEWEB)

    Schlahta, S.N.; Brouns, T.M.

    1998-06-01

    The Tanks Focus Area (TFA) serves as the DOE`s Office of Environmental Management`s national technology and solution development program for radioactive waste tank remediation. Its technical scope covers the major functions that comprise a complete tank remediation system: waste retrieval, waste pretreatment, waste immobilization, tank closure, and characterization of both the waste and tank with safety integrated into all the functions. In total, 17 technologies and technical solutions were selected for review. The purpose of each review was to understand the state of development of each technology selected for review and to identify issues to be resolved before the technology or technical solution progressed to the next level of maturity. The reviewers provided detailed technical and programmatic recommendations and comments. The disposition of these recommendations and comments and their impact on the program is documented in this report.

  14. Tanks Focus Area FY98 midyear technical review

    International Nuclear Information System (INIS)

    Schlahta, S.N.; Brouns, T.M.

    1998-06-01

    The Tanks Focus Area (TFA) serves as the DOE's Office of Environmental Management's national technology and solution development program for radioactive waste tank remediation. Its technical scope covers the major functions that comprise a complete tank remediation system: waste retrieval, waste pretreatment, waste immobilization, tank closure, and characterization of both the waste and tank with safety integrated into all the functions. In total, 17 technologies and technical solutions were selected for review. The purpose of each review was to understand the state of development of each technology selected for review and to identify issues to be resolved before the technology or technical solution progressed to the next level of maturity. The reviewers provided detailed technical and programmatic recommendations and comments. The disposition of these recommendations and comments and their impact on the program is documented in this report

  15. Z plant aggregate area management study technical baseline report

    International Nuclear Information System (INIS)

    DeFord, D.H.; Carpenter, R.W.

    1995-05-01

    This document was prepared in support of the development of a Aggregate Area Management Study of Z Plant, 200 West Area, at the US Department of Energy (DOE) Hanford Site near Richland, Washington. It provides a technical description and operational history of the aggregate area and results from an environmental investigation undertaken by the Technical Baseline Section of the Environmental Engineering Group, Westinghouse Hanford Company (WHC) which is currently the Waste Site and Facility Research Office, Natural Resources, Bechtel Hanford, Inc. (BHI). It is based upon review and evaluation of numerous Hanford Site current and historical reports, drawings and photographs, supplemented with site inspections and employee interviews. No intrusive field investigations or sampling were conducted in support of this report

  16. Auxiliary energy in building technical services - Potential for savings and ways toward implementation; Hilfsenergie Haustechnik: Einspar-Potenziale und Umsetzungspfade

    Energy Technology Data Exchange (ETDEWEB)

    Nipkow, J. [Schweizerische Agentur fuer Energieeffizienz (SAFE), Zuerich (Switzerland); Peters, M.; Wapf, B. [Econcept AG, Zuerich (Switzerland)

    2006-11-15

    This report for the Swiss Federal Office of Energy (SFOE) examines the potential available for saving energy in the building technical services area. Savings of six to eight percent are noted for the area concerning pumps, fans, control systems, etc. The report presents the aims of the project and reviews the definition of auxiliary energy. National and international energy labels, limiting values and typical values for efficiency are examined. The results of surveys are presented and discussed as are the opinions and suggestions of planners, installers and architects. Manufacturers' opinions and marketing aspects are briefly examined, as are energy labels and regulations. Implementation of measures in various areas are described. Economical aspects and actions to be taken are discussed and educational measures are looked at. Follow-up projects are defined.

  17. Segmentation of Shadowed Buildings in Dense Urban Areas from Aerial Photographs

    Directory of Open Access Journals (Sweden)

    Junichi Susaki

    2012-03-01

    Full Text Available Segmentation of buildings in urban areas, especially dense urban areas, by using remotely sensed images is highly desirable. However, segmentation results obtained by using existing algorithms are unsatisfactory because of the unclear boundaries between buildings and the shadows cast by neighboring buildings. In this paper, an algorithm is proposed that successfully segments buildings from aerial photographs, including shadowed buildings in dense urban areas. To handle roofs having rough textures, digital numbers (DNs are quantized into several quantum values. Quantization using several interval widths is applied during segmentation, and for each quantization, areas with homogeneous values are labeled in an image. Edges determined from the homogeneous areas obtained at each quantization are then merged, and frequently observed edges are extracted. By using a “rectangular index”, regions whose shapes are close to being rectangular are thus selected as buildings. Experimental results show that the proposed algorithm generates more practical segmentation results than an existing algorithm does. Therefore, the main factors in successful segmentation of shadowed roofs are (1 combination of different quantization results, (2 selection of buildings according to the rectangular index, and (3 edge completion by the inclusion of non-edge pixels that have a high probability of being edges. By utilizing these factors, the proposed algorithm optimizes the spatial filtering scale with respect to the size of building roofs in a locality. The proposed algorithm is considered to be useful for conducting building segmentation for various purposes.

  18. Commercial Building Energy Asset Score System: Program Overview and Technical Protocol (Version 1.0)

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Na; Gorrissen, Willy J.

    2013-01-11

    The U.S. Department of Energy (DOE) is developing a national voluntary energy asset score system that includes an energy asset score tool to help building owners evaluate their buildings with respect to the score system. The goal of the energy asset score system is to facilitate cost-effective investment in energy efficiency improvements of commercial buildings. The system will allow building owners and managers to compare their building infrastructure against peers and track building upgrade progress over time. The system can also help other building stakeholders (e.g., building operators, tenants, financiers, and appraisers) understand the relative efficiency of different buildings in a way that is independent from their operations and occupancy. This report outlines the technical protocol used to generate the energy asset score, explains the scoring methodology, and provides additional details regarding the energy asset score tool. This report also describes alternative methods that were considered prior to developing the current approach. Finally, this report describes a few features of the program where alternative approaches are still under evaluation.

  19. S Plant Aggregate Area Management study technical baseline report

    International Nuclear Information System (INIS)

    DeFord, D.H.; Carpenter, R.W.

    1995-05-01

    This document is prepared in support of an Aggregate Area Management Study of S Plant, 200 West Area, at the US Department of Energy's (DOE) Hanford Site near Richland, Washington. It provides a technical baseline of the aggregate area and the results from an environmental investigation undertaken by the Technical Baseline Section of the Environmental Engineering Group, Westinghouse Hanford Company (WHC). This document is based on review and evaluation of numerous Hanford Site current and historical reports, drawings and photographs, supplemented with site inspections and employee interviews. This report describes the REDOX facility and its waste sites, including cribs, french drains, septic tanks and drain fields, trenches, catch tanks, settling tanks, diversion boxes, underground tank farms designed for high-level liquid wastes, and the lines and encasements that connect them

  20. Energy usage and technical potential for energy saving measures in the Swedish residential building stock

    International Nuclear Information System (INIS)

    Mata, Érika; Sasic Kalagasidis, Angela; Johnsson, Filip

    2013-01-01

    This paper provides an analysis of the current energy usage (net energy and final energy by fuels) and associated carbon dioxide (CO 2 ) emissions of the Swedish residential building stock, which includes single-family dwellings and multi-family dwellings. Twelve energy saving measures (ESMs) are assessed using a bottom–up modeling methodology, in which the Swedish residential stock is represented by a sample of 1400 buildings (based on data from the year 2005). Application of the ESMs studied gives a maximum technical reduction potential in energy demand of 53%, corresponding to a 63% reduction in CO 2 emissions. Although application of the investigated ESMs would reduce CO 2 emissions, the measures that reduce electricity consumption for lighting and appliances (LA) will increase CO 2 emissions, since the saved electricity production is less CO 2 -intensive than the fuel mix used for the increased space heating required to make up for the loss in indirect heating obtained from LA. - Highlights: ► Analysis of year 2005energy use and CO2 emissions of Swedish residential buildings. ► Includes all single-family dwellings and multi-family dwellings. ► Bottom–up modeling of building stock represented by 1400 buildings. ► Technical effects of 12 energy saving measures are assessed. ► Energy demand can be reduced by53% and associated CO 2 emissions by 63%

  1. Involvement of Individuals in the Development of Technical Solutions and Rules of Management for Building Renovation Projects: A Case Study of Latvia

    Science.gov (United States)

    Pukite, I.; Grekis, A.; Geipele, I.; Zeltins, N.

    2017-08-01

    In March 2016, the Latvian government approved a new support program for increasing energy efficiency in residential apartment buildings. For the support of renovation of apartment buildings in the period from 2016 to 2023, 166 470 588 EUR will be available. Different persons, such as energy auditors, designers, architects, project managers and builders, will be involved in the process of planning, development and implementation of building renovation. At the development stage of the building renovation project, special attention should be devoted to the first stage - energy audit and technical project development. The problem arises due to the fact that each of these individuals, during the development of technical building documentation, does not work as a completely unified system. The implementation of construction project planning and organisational management system is one of the most important factors to guarantee that the quality of building renovation project is ensured in accordance with the laws and regulatory standards. The paper studies mutual cooperation, professionalism and the role of information feedback of personnel involved in the planning stage of building renovation, which is an essential prerequisite for the renovation process in order to achieve high quality of work and reduce the energy performance indicator. The present research includes the analysis of different technical solutions and their impact on energy efficiency. Mutual harmonisation of technical specifications is also investigated.

  2. Comfort Study of Office Buildings with Large Glazed Areas

    Directory of Open Access Journals (Sweden)

    Violeta Motuzienė

    2017-09-01

    Full Text Available In the buildings with large glazed areas the biggest problem is the space overheating during the warm season. This causes increased energy demand for cooling. The survey was carried out during the warm and cold seasons in two office buildings with large glazed areas. The methodology was prepared for evaluating indoor climate parameters using objective and subjective evaluation. The measurements have shown that there are problems with lighting in workplaces of both buildings during both the warm and cold seasons. The biggest problem is too dry air during the cold period, an acceptable temperature is also not always in the building No. 2. The survey has shown that some employees are dissatisfied with the indoor climate in the workplace, the bigger dissatisfaction is in building No. 2. Assessing according to the O. Fanger methodology was obtained that the number of PPD is in the normal range during the cold period, whereas close to the limit when the building can not be operated in the warm period.

  3. Social acceptance of renewable energy technologies for buildings in the Helsinki Metropolitan Area of Finland

    NARCIS (Netherlands)

    Jung, N.; Moula, M.E.; Fang, T.; Hamdy, M.; Lahdelma, R.

    2016-01-01

    The application of renewable energy technologies (RETs) in the residential building sector requires acceptance of technical solutions by key stakeholders, such as building owners, real-estate developers, and energy providers. The objective of this study is to identify the current status of public

  4. Radon risk in residential buildings

    International Nuclear Information System (INIS)

    Niewiadomski, T.

    1996-01-01

    The author discusses the risk related to the inhalation of radon decay products. This products are the cause of almost the half of the doses absorbed by the people. The concentration of radon in buildings is much higher than in the open areas and its country average in Poland is 50 Bq/m 3 . It is difficult to predict the concentration of radon in the building without measurement. Author concludes that there are technical means to decrease radon concentration in buildings

  5. Academic & Technical Skills + Life/Work Skills + Career Information & Guidance = Success in Career Building.

    Science.gov (United States)

    Jarvis, Phillip S.

    There has been a renaissance in the thinking about career development. It is becoming accepted that information is not enough; in addition to academic and technical skills, youth and adults need to learn life/work designing and building skills to become healthy, productive, and self-reliant citizens. Despite the fact that Canadian students have…

  6. Building technical and social confidence in the safety of geological disposal in Japan

    International Nuclear Information System (INIS)

    Tochiyama, Osamu; Masuda, Sumio

    2013-01-01

    Geological disposal has been adopted as the most feasible option for the method of long-term management of high-level radioactive waste (HLW) in every country in the world, regardless of the pros and cons of the nuclear power generation. Building stakeholders’ confidence in safety of geological disposal is indispensable to reach the point where the implementation of geological disposal is accepted by the current generation. The safety case is a key input to build confidence in geological disposal stepwise as the program progresses and regarded to play an important role as a common platform in the communication among stakeholders. The aim of this paper is to review arguments relevant to building technical and social confidence in the progress of Japanese research and development activities as well as international discussions. (author)

  7. Technical evaluation: 300 Area steam line valve accident

    International Nuclear Information System (INIS)

    1993-08-01

    On June 7, 1993, a journeyman power operator (JPO) was severely burned and later died as a result of the failure of a 6-in. valve that occurred when he attempted to open main steam supply (MSS) valve MSS-25 in the U-3 valve pit. The pit is located northwest of Building 331 in the 300 Area of the Hanford Site. Figure 1-1 shows a layout of the 300 Area steam piping system including the U-3 steam valve pit. Figure 1-2 shows a cutaway view of the approximately 10- by 13- by 16-ft-high valve pit with its various steam valves and connecting piping. Valve MSS-25, an 8-in. valve, is located at the bottom of the pit. The failed 6-in. valve was located at the top of the pit where it branched from the upper portion of the 8-in. line at the 8- by 8- by 6-in. tee and was then ''blanked off'' with a blind flange. The purpose of this technical evaluation was to determine the cause of the accident that led to the failure of the 6-in. valve. The probable cause for the 6-in. valve failure was determined by visual, nondestructive, and destructive examination of the failed valve and by metallurgical analysis of the fractured region of the valve. The cause of the accident was ultimately identified by correlating the observed failure mode to the most probable physical phenomenon. Thermal-hydraulic analyses, component stress analyses, and tests were performed to verify that the probable physical phenomenon could be reasonably expected to produce the failure in the valve that was observed

  8. 14 CFR 151.93 - Buildings; utilities; sidewalks; parking areas; and landscaping.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Buildings; utilities; sidewalks; parking....93 Buildings; utilities; sidewalks; parking areas; and landscaping. (a) Only buildings or parts of buildings intended to house facilities or activities directly related to the safety of persons at the...

  9. Technical Basis Document for PFP Area Monitoring Dosimetry Program

    CERN Document Server

    Cooper, J R

    2000-01-01

    This document describes the phantom dosimetry used for the PFP Area Monitoring program and establishes the basis for the Plutonium Finishing Plant's (PFP) area monitoring dosimetry program in accordance with the following requirements: Title 10, Code of Federal Regulations (CFR), part 835, ''Occupational Radiation Protection'' Part 835.403; Hanford Site Radiological Control Manual (HSRCM-1), Part 514; HNF-PRO-382, Area Dosimetry Program; and PNL-MA-842, Hanford External Dosimetry Technical Basis Manual.

  10. Technical Basis Document for PFP Area Monitoring Dosimetry Program

    International Nuclear Information System (INIS)

    COOPER, J.R.

    2000-01-01

    This document describes the phantom dosimetry used for the PFP Area Monitoring program and establishes the basis for the Plutonium Finishing Plant's (PFP) area monitoring dosimetry program in accordance with the following requirements: Title 10, Code of Federal Regulations (CFR), part 835, ''Occupational Radiation Protection'' Part 835.403; Hanford Site Radiological Control Manual (HSRCM-1), Part 514; HNF-PRO-382, Area Dosimetry Program; and PNL-MA-842, Hanford External Dosimetry Technical Basis Manual

  11. 100 Areas technical activities report, engineers - March 1951

    Energy Technology Data Exchange (ETDEWEB)

    1951-04-01

    This is the monthly 100 areas technical activities report from the engineering division for the month of March 1951. It reports on engineering activities related directly to the different production reactors, and gives progress reports on various engineering projects which are in development by the engineering group.

  12. The Two-Year Colleges' Role in Building the Future Geoscience Technical Workforce

    Science.gov (United States)

    Wolfe, B.

    2014-12-01

    Careers in energy science related fields represent significant job growth in the U.S. Yet post-secondary career and technical programs have not kept pace with demand and energy science curriculum, including fundamental concepts of energy generation and environmental impact, lacks a firm position among general or career and technical education courses. Many of these emerging energy related jobs are skilled labor and entry level technical positions requiring less than a bachelor's degree. These include jobs such as solar/photovoltaic design and installation, solar water and space heating installation, energy management, efficiency and conservation auditor, environmental technician, etc. These energy related career pathways fit naturally within the geosciences discipline. Many of these jobs can be filled by individuals from HVAC, Industrial technology, welding, and electrical degree programs needing some additional specialized training and curriculum focused on fundamental concepts of energy, fossil fuel exploration and use, atmospheric pollution, energy generation, alternative energy sources, and energy conservation. Two-year colleges (2ycs) are uniquely positioned to train and fill these workforce needs as they already have existing career and technical programs and attract both recent high school graduates, as well as non-traditional students including displaced workers and returning veterans. We have established geoscience related workforce certificate programs that individuals completing the traditional industrial career and technical degrees can obtain to meet these emerging workforce needs. This presentation will discuss the role of geosciences programs at 2ycs in training these new workers, developing curriculum, and building a career/technical program that is on the forefront of this evolving industry.

  13. Buildings Interoperability Landscape

    Energy Technology Data Exchange (ETDEWEB)

    Hardin, Dave [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stephan, Eric G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wang, Weimin [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Corbin, Charles D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Widergren, Steven E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-12-31

    Through its Building Technologies Office (BTO), the United States Department of Energy’s Office of Energy Efficiency and Renewable Energy (DOE-EERE) is sponsoring an effort to advance interoperability for the integration of intelligent buildings equipment and automation systems, understanding the importance of integration frameworks and product ecosystems to this cause. This is important to BTO’s mission to enhance energy efficiency and save energy for economic and environmental purposes. For connected buildings ecosystems of products and services from various manufacturers to flourish, the ICT aspects of the equipment need to integrate and operate simply and reliably. Within the concepts of interoperability lie the specification, development, and certification of equipment with standards-based interfaces that connect and work. Beyond this, a healthy community of stakeholders that contribute to and use interoperability work products must be developed. On May 1, 2014, the DOE convened a technical meeting to take stock of the current state of interoperability of connected equipment and systems in buildings. Several insights from that meeting helped facilitate a draft description of the landscape of interoperability for connected buildings, which focuses mainly on small and medium commercial buildings. This document revises the February 2015 landscape document to address reviewer comments, incorporate important insights from the Buildings Interoperability Vision technical meeting, and capture thoughts from that meeting about the topics to be addressed in a buildings interoperability vision. In particular, greater attention is paid to the state of information modeling in buildings and the great potential for near-term benefits in this area from progress and community alignment.

  14. Technical Basis Document for PFP Area Monitoring Dosimetry Program

    Energy Technology Data Exchange (ETDEWEB)

    COOPER, J.R.

    2000-04-17

    This document describes the phantom dosimetry used for the PFP Area Monitoring program and establishes the basis for the Plutonium Finishing Plant's (PFP) area monitoring dosimetry program in accordance with the following requirements: Title 10, Code of Federal Regulations (CFR), part 835, ''Occupational Radiation Protection'' Part 835.403; Hanford Site Radiological Control Manual (HSRCM-1), Part 514; HNF-PRO-382, Area Dosimetry Program; and PNL-MA-842, Hanford External Dosimetry Technical Basis Manual.

  15. Identification of Vital Areas at Nuclear Facilities. Technical Guidance

    International Nuclear Information System (INIS)

    2012-01-01

    The possibility that nuclear or other radioactive material could be used for malicious purposes cannot be ruled out in the current global situation. States have responded to this risk by engaging in a collective commitment to strengthen the protection and control of such material and to effectively respond to nuclear security events. States have agreed to strengthen existing and established new international legal instruments to enhance nuclear security around the world. Nuclear security is fundamental in the management of nuclear technologies and in applications where nuclear or other radioactive material is used or transported. Through its nuclear security programme, the IAEA supports States to establish, maintain and sustain an effective nuclear security regime. The IAEA has adopted a comprehensive approach to nuclear security. This recognizes that an effective national nuclear security regime builds on: the implementation of relevant international legal instruments; information protection; physical protection; material accounting and control; detection of and response to trafficking in such material; national response plans; and contingency measures. With its nuclear security series, the IAEA aims to assist States to implement and sustain such a regime in a coherent and integrated manner. The IAEA Nuclear Security Series comprises: Nuclear Security Fundamentals, which include objectives and essential elements of a State?s nuclear security regime; Recommendations; Implementing Guides; and Technical Guidance publications. Each State carries the full responsibility for nuclear security, i.e. to provide for the security of nuclear and other radioactive material and associated facilities and activities; to ensure the security of such material in use, storage or in transport; and to combat illicit trafficking and the inadvertent movement of such material. It should also be prepared to respond to a nuclear security event. The IAEA recommendations for the protection of

  16. Application issues for large-area electrochromic windows incommercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eleanor S.; DiBartolomeo, D.L.

    2000-05-01

    Projections of performance from small-area devices to large-area windows and enterprise marketing have created high expectations for electrochromic glazings. As a result, this paper seeks to precipitate an objective dialog between material scientists and building-application scientists to determine whether actual large-area electrochromic devices will result in significant performance benefits and what material improvements are needed, if any, to make electrochromics more practical for commercial building applications. Few in-situ tests have been conducted with large-area electrochromic windows applied in buildings. This study presents monitored results from a full-scale field test of large-area electrochromic windows to illustrate how this technology will perform in commercial buildings. The visible transmittance (Tv) of the installed electrochromic ranged from 0.11 to 0.38. The data are limited to the winter period for a south-east-facing window. The effect of actual device performance on lighting energy use, direct sun control, discomfort glare, and interior illumination is discussed. No mechanical system loads were monitored. These data demonstrate the use of electrochromics in a moderate climate and focus on the most restrictive visual task: computer use in offices. Through this small demonstration, we were able to determine that electrochromic windows can indeed provide unmitigated transparent views and a level of dynamic illumination control never before seen in architectural glazing materials. Daily lighting energy use was 6-24 percent less compared to the 11 percent-glazing, with improved interior brightness levels. Daily lighting energy use was 3 percent less to 13 percent more compared to the 38 percent-glazing, with improved window brightness control. The electrochromic window may not be able to fulfill both energy-efficiency and visual comfort objectives when low winter direct sun is present, particularly for computer tasks using cathode-ray tube (CRT

  17. Integration of PV modules in existing Romanian buildings from rural areas

    Energy Technology Data Exchange (ETDEWEB)

    Fara, S.; Finta, D. [IPA SA Research Development, Engineering and Manufacturing for Automation Equipment and Systems, Bucharest (Romania); Fara, L.; Comaneci, D. [Polytechnic Univ. of Bucharest (Romania); Dabija, A.M. [Univ. of Architecture and Urbanism Ion Mincu, Bucharest (Romania); Tulcan-Paulescu, E. [West Univ. of Timisoara, Timisoara (Romania)

    2010-07-01

    Romania has launched a national research project to promote the use of distributed solar architecture and the use of BIPV systems. These systems include solar tunnels and active solar photovoltaic (PV) systems installed on the roofs and facades of buildings in rural areas. In contrast to other EU states, Romania does not have a photovoltaic building construction branch. The number of isolated cases are insufficient to identify a starting point regarding the PV market in the building industry. The main objective of the project is to demonstrate the efficiency of integrating various PV elements in buildings from rural areas, to test them and to make them known so that they can be used on a large scale. This will be accomplished by installing new products on 2 buildings in Bucharest and in 1 building in Timisoara. The PV modules will be integrated with the architecture. One of the buildings will be a historical building while the other 2 will be new buildings with different typologies. The installed power for each building will be of about 1.000 Wp, including some technologies with PV modules.

  18. Building 774: open for business

    CERN Multimedia

    CERN Bulletin

    2015-01-01

    In July 2012, the demolition of Building 936 on the Prévessin site marked the start of the Building 774 project. On 23 February, less than three years later, the new 3900 m2 building was handed over to the BE department.   The brand new Building 774. (Credits: Francesco Soppelsa) Located near to the CERN Control Centre, Building 774 contains offices, laboratories and meeting rooms, as well as a huge public area consisting of a 104-seat auditorium, a changing room/shower area in the basement and a pleasant cafeteria open from 8 a.m. to 5 p.m., offering a wide range of refreshments including hot meals at lunchtime. “There were a few twists and turns during the construction of this building, but it all turned out well in the end!" says Michael Poehler, a member of the GS-SE group and the technical coordinator of the project. (Credits: Francesco Soppelsa) The 120 occupants of the building have just moved into their brand new home, bringing all the members of the...

  19. Tornado Protection: Selecting and Designing Safe Areas in Buildings.

    Science.gov (United States)

    Abernethy, James J.

    Tornadoes and extreme winds cause heavy loss of life and property damage throughout the United States. Most buildings offer significant protection from this danger, and building administrators should know the areas where this protection is available. This booklet presents a review of three schools, all of which were struck by tornadoes on April 3,…

  20. Serviceability criteria for buildings in mine subsidence area -- Adjustment to Eurocodes

    International Nuclear Information System (INIS)

    Kawulok, M.; Sulimowski, Z.

    1994-01-01

    Due to ground deformations caused by underground mining, building structures in mining areas are frequently subjected to considerable deformations and damage to the finishing and structural elements. As a consequence, serviceable values of such structures are distinctly diminished, and in extreme cases, seriously damaged structures may be exempted from further service. These problems are not duly represented in the existing building standard codes. It is also important to determine relationship between damage stage and value of the building, and hence the strategy for reconstruction or renovation works. The paper presents proposals concerning serviceability criteria of building structures in mining areas, in terms of basic standard requirements valid in building in Poland, as well as proposals of Eurocodes. Building structures under consideration have been divided into structures designed to resist mining influences and existing structures, not adapted to conform to these influences at the design and erection stages

  1. INDUCON building concept; INDUCON-rakennuskonsepti

    Energy Technology Data Exchange (ETDEWEB)

    Sarja, A.; Laine, J.; Pulakka, S.; Saari, M. [VTT Building and Transport, Espoo (Finland)

    2003-08-01

    The new and stronger requirements: lifetime economy, functionality in use and in changes of use, technical lifetime performance, energy efficiency, healthy, safety, ecology and local culture, are serving a challenge for the building technology. Additionally the pressure towards decreasing the construction costs with the increase of productivity of the work and capital is increased. The objective of this research work has been to respond the challenges described above with creating alternative building concepts, which could allow production of individually designed apartment and office buildings, including methodology and methods to optimise the building concepts and individual buildings in relation to the lifetime quality. Building concept is a repeatable and documented way of design and construction, which can result in individual buildings with an optimised and high lifetime quality. Lifetime quality is the capability of a building to fulfil the requirements of the users, owners and society during entire design period of the building. The INDUCON building concept is focused on the following issues: Classified and optimised lifetime quality (incl. the viewpoints of functionality, performance, economy, ecology and culture), and the realisation of industrial production on an advanced level (incl. new models of building design and construction, simplification of building systems and products, decrease of the number of parts of buildings, improvement of finishing of the prefabricated components and modules, and improving the interaction and compatibility of structures and building service systems). As a result are presented: systematised and classified definitions of performance properties of buildings; corresponding specifications of building systems, modules and components; design principles, process descriptions; examples (incl. Routings of technical building services, specification and classification of the health and comfort properties of indoor air, calculations

  2. Technical Support Document: The Development of the Advanced Energy Design Guide for Highway Lodging Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Wei; Jarnagin, Ronald E.; Gowri, Krishnan; McBride, M.; Liu, Bing

    2008-09-30

    This Technical Support Document (TSD) describes the process and methodology for development of the Advanced Energy Design Guide for Highway Lodgings (AEDG-HL or the Guide), a design guidance document intended to provide recommendations for achieving 30% energy savings in highway lodging properties over levels contained in ANSI/ASHRAE/IESNA Standard 90.1-1999, Energy Standard for Buildings Except Low-Rise Residential Buildings. The AEDG-HL is the fifth in a series of guides being developed by a partnership of organizations, including the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (ASHRAE), the American Institute of Architects (AIA), the Illuminating Engineering Society of North America (IESNA), the United States Green Buildings Council (USGBC), and the U.S. Department of Energy (DOE).

  3. Technical Support Document: The Development of the Advanced Energy Design Guide for Small Retail Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Bing; Jarnagin, Ronald E.; Winiarski, David W.; Jiang, Wei; McBride, Merle F.; Crall, C.

    2006-09-30

    The Advanced Energy Design Guide for Small Retail Buildings (AEDG-SR) was developed by a partnership of organizations, including the American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE), the American Institute of Architects (AIA), the Illuminating Engineering Society of North America (IESNA), the United States Green Buildings Council (USGBC), and the Department of Energy (DOE). The guide is intended to offer recommendations to achieve 30% energy savings and thus to encourage steady progress towards net-zero energy buildings. The baseline level energy use was set at buildings built at the turn of the millennium, which are assumed to be based on ANSI/ASHRAE/IESNA Standard 90.1-1999, Energy Standard for Buildings Except Low-Rise Residential Buildings (refer to as the ?Standard? in this report). ASHRAE and its partners are engaged in the development of a series of guides for small commercial buildings, with the AEDG-SR being the second in the series. Previously the partnership developed the Advanced Energy Design Guide for Small Office Buildings: Achieving 30% Energy Savings Over ANSI/ASHRAE/IESNA Standard 90.1-1999, which was published in late 2004. The technical support document prepared by PNNL details how the energy analysis performed in support of the Guide and documents development of recommendation criteria.

  4. Corrective measures evaluation report for technical area-v groundwater.

    Energy Technology Data Exchange (ETDEWEB)

    Witt, Johnathan L (North Wind, Inc., Idaho Falls, ID); Orr, Brennon R. (North Wind, Inc., Idaho Falls, ID); Dettmers, Dana L. (North Wind, Inc., Idaho Falls, ID); Hall, Kevin A. (North Wind, Inc., Idaho Falls, ID); Howard, Hope (North Wind, Inc., Idaho Falls, ID)

    2005-07-01

    This Corrective Measures Evaluation Report was prepared as directed by the Compliance Order on Consent issued by the New Mexico Environment Department to document the process of selecting the preferred remedial alternative for contaminated groundwater at Technical Area V. Supporting information includes background information about the site conditions and potential receptors and an overview of work performed during the Corrective Measures Evaluation. Evaluation of remedial alternatives included identification and description of four remedial alternatives, an overview of the evaluation criteria and approach, qualitative and quantitative evaluation of remedial alternatives, and selection of the preferred remedial alternative. As a result of the Corrective Measures Evaluation, it was determined that monitored natural attenuation of all contaminants of concern (trichloroethene, tetrachloroethene, and nitrate) was the preferred remedial alternative for implementation as the corrective measure to remediate contaminated groundwater at Technical Area V of Sandia National Laboratories/New Mexico. Finally, design criteria to meet cleanup goals and objectives and the corrective measures implementation schedule for the preferred remedial alternative are presented.

  5. Field Implementation Plan for the In-Situ Bioremediation Treatability Study at the Technical Area-V Groundwater Area of Concern

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jun [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-10-31

    This Field Implementation Plan (FIP) was prepared by Sandia National Laboratories, New Mexico (SNL/NM) and provides instruction on conducting a series of in-situ bioremediation (ISB) tests as described in the Revised Treatability Study Work Plan for In-Situ Bioremediation at the Technical Area-V Groundwater Area of Concern, referred to as the Revised Work Plan in this FIP. The Treatability Study is designed to gravity inject an electron-donor substrate and bioaugmentation bacteria into groundwater via three injection wells to perform bioremediation of the constituents of concern (COCs), nitrate and trichloroethene (TCE), in the regions with the highest concentrations at the Technical Area-V Groundwater (TAVG) Area of Concern (AOC). The Treatability Study will evaluate the effectiveness of bioremediation solution delivery and COC treatment over time. This FIP is designed for SNL/NM work planning and management. It is not intended to be submitted for regulator’s approval. The technical details presented in this FIP are subject to change based on field conditions, availability of equipment and materials, feasibility, and inputs from Sandia personnel and Aboveground Injection System contractor.

  6. Field Implementation Plan for the In-Situ Bioremediation Treatability Study at the Technical Area-V Groundwater Area of Concern

    International Nuclear Information System (INIS)

    Li, Jun

    2016-01-01

    This Field Implementation Plan (FIP) was prepared by Sandia National Laboratories, New Mexico (SNL/NM) and provides instruction on conducting a series of in-situ bioremediation (ISB) tests as described in the Revised Treatability Study Work Plan for In-Situ Bioremediation at the Technical Area-V Groundwater Area of Concern, referred to as the Revised Work Plan in this FIP. The Treatability Study is designed to gravity inject an electron-donor substrate and bioaugmentation bacteria into groundwater via three injection wells to perform bioremediation of the constituents of concern (COCs), nitrate and trichloroethene (TCE), in the regions with the highest concentrations at the Technical Area-V Groundwater (TAVG) Area of Concern (AOC). The Treatability Study will evaluate the effectiveness of bioremediation solution delivery and COC treatment over time. This FIP is designed for SNL/NM work planning and management. It is not intended to be submitted for regulator's approval. The technical details presented in this FIP are subject to change based on field conditions, availability of equipment and materials, feasibility, and inputs from Sandia personnel and Aboveground Injection System contractor.

  7. Rural water tanks with HFB technique: technical guide

    CSIR Research Space (South Africa)

    Solsona, F

    1991-03-01

    Full Text Available This technical guide describes a very simple technique for water tank construction called H-F-B (heart filled blocks). The technique makes use of a simple mould (which can be made even in rural areas) for the manufacture of concrete building blocks...

  8. Ten questions concerning integrating smart buildings into the smart grid

    Energy Technology Data Exchange (ETDEWEB)

    Lawrence, Thomas M.; Boudreau, Marie-Claude; Helsen, Lieve; Henze, Gregor; Mohammadpour, Javad; Noonan, Doug; Patteeuw, Dieter; Pless, Shanti; Watson, Richard T.

    2016-11-01

    Recent advances in information and communications technology (ICT) have initiated development of a smart electrical grid and smart buildings. Buildings consume a large portion of the total electricity production worldwide, and to fully develop a smart grid they must be integrated with that grid. Buildings can now be 'prosumers' on the grid (both producers and consumers), and the continued growth of distributed renewable energy generation is raising new challenges in terms of grid stability over various time scales. Buildings can contribute to grid stability by managing their overall electrical demand in response to current conditions. Facility managers must balance demand response requests by grid operators with energy needed to maintain smooth building operations. For example, maintaining thermal comfort within an occupied building requires energy and, thus an optimized solution balancing energy use with indoor environmental quality (adequate thermal comfort, lighting, etc.) is needed. Successful integration of buildings and their systems with the grid also requires interoperable data exchange. However, the adoption and integration of newer control and communication technologies into buildings can be problematic with older legacy HVAC and building control systems. Public policy and economic structures have not kept up with the technical developments that have given rise to the budding smart grid, and further developments are needed in both technical and non-technical areas.

  9. Savannah River Plant engineering and design history. Volume 4: 300/700 Areas & general services and facilities

    Energy Technology Data Exchange (ETDEWEB)

    1957-01-01

    The primary function of the 300 Area is the production and preparation of the fuel and target elements required for the 100 Area production reactors. Uranium slugs and lithium-aluminium alloy control and blanket rods are prepared in separate structures. Other facilities include a test pile, a physics assembly laboratory, an office and change house, an electrical substation, and various service facilities such as rail lines, roads, sewers, steam and water distribution lines, etc. The 700 Area contains housing and facilities for plant management, general plant services, and certain technical activities. The technical buildings include the Main Technical Laboratory, the Waste Concentration Building, the Health Physics Headquarters, and the Health Physics Calibration building. Sections of this report describe the following: development of the 300-M Area; selection and description of process; design of main facilities of the 300 Area; development of the 700-A Area; design of the main facilities of the 700 Area; and general services and facilities, including transportation, plant protection, waste disposal and drainage, site work, pilot plants, storage, and furniture and fixtures.

  10. The potential to supply low temperature district heating to existing building area

    DEFF Research Database (Denmark)

    Li, Hongwei; Svendsen, Svend

    2013-01-01

    Low-temperature district heating (LTDH) has the advantages as reduced network heat loss, improved quality match between energy supply and energy demand, and increased utilization of low-grade waste heat and renewable energy. The LTDH represents the next generation district heating (DH) system...... to supply existing building areas which are characterized with high heating demand needs to be examined. In this paper, the DH network deliverable capacity to supply LTDH to an existing building area is studied based on building thermal performance and DH network hydraulic performance simulation....

  11. Systems study 'Alternative Entsorgung'. Final report. Technical annex 10

    International Nuclear Information System (INIS)

    Hartje, B.; Kronschnabel, H.; Mueller, W.F.W.

    1984-01-01

    There is an investigation whether accessibility can be produced to fuel elements stored in a salt mine. All solutions of the problem were followed up until the technically best one was found. Two conditions must be fulfilled for access to the final storage barrel: - There must be a climate which is suitable for people. The Mining Order is the basis for this. - The pit building must be fixed, in the convergence in the salt mine should not lead to it becoming impossible to reach part of the mine. Due to heat-producing waste, rock temperatures are caused in the salt mine, in which mining is no longer possible. Building on the idea of cooling the whole final storage area using concentric sections, the amount of heat to be removal was first estimated. Cooling of the whole final storage area proved to be technically unjustifiable and uninteresting at present. (orig./HP) [de

  12. Communication of technical building systems. Interfaces, protocols and solutions; Kommunikation technischer Gebaeudesysteme. Schnittstellen, Protokolle und Loesungen

    Energy Technology Data Exchange (ETDEWEB)

    Kranz, H.R. [Siemens AG, Karlsruhe (Germany)

    1995-12-31

    In chapter 18 of the anthology about building control the communication between and with technical building systems is described. After the basics have been explained in the previous chapter interfaces, protocols and solutions are presented in this part. The following aspects are discussed: homogeneous and heterogeneous building automation systems, communication in the field of building automation, demands and characteristic numbers, open communication between heterogeneous systems, announcement and award procedures, protocol selection, FND - firm neutral data transmission system, PROFIBUS, ISP (InterOperable Systems Project) and Fieldbus Foundation with ``profile``; EIB (European Installation Bus), the standard bus for building system technology, BACNet (Building Automation Control Network) and EcheLON, open systems for building automation. (BWI) [Deutsch] Kapitel 18 des Sammelbandes ueber Building Control geht auf das Thema der Kommunikation zwischen und mit technischen Gebaeudesystemen ein. Nachdem im vorherigen Kapitel die Grundlagen besprochen wurden, wird im vorliegenden Teil auf Schnittstellen, Protokolle und Loesungen eingegangen. In diesem Zusammenhang werden folgenden Themenbereiche angesprochen: Homogene und heterogene GA-Systeme; Kommunikation in der Gebaeudeautomation; Anforderungen und Kennwert; offene Kommunikation heterogener Systeme; Ausschreibungs- und Vergabeprozeduren; Protokollauswahl; FND, das firmenneutrale Datenuebertragungsprotokoll; PROFIBUS, ISP und Fieldbus Foundation mit `Profil`; EIB, der Standardbus fuer die Gebaeudesystemtechnik; BACNet und EcheLON; Offene Systeme fuer die Gebaeudeautomation. (BWI)

  13. Artificial intelligence applications in fixed area monitor for TRIGA reactor building and service building

    International Nuclear Information System (INIS)

    Talpalariu, C.; Talpalariu, J.; Vaja, N.; Matei, C.

    2008-01-01

    This system is intended for the protection of personnel working in those areas of the Reactor Building and Service Building where high gamma radiation fields are expected. A detector, sensitive to gamma radiation, is installed in each of the areas to be monitored. The detector will send a signal, proportional to the radiation level in the area, to a corresponding electronic module (Alarm Unit), where the signal will be amplified and checked against alarm set points for possible alarming conditions. In case the field exceeds the alarm set values, the Alarm Unit will produce a signal that will trigger the field alarms (Horn and Beacon) located in the area where the condition occurred. Each Alarm Unit will send a numerical input to central computer command. he system is required to accomplish the following tasks: - Monitors the level of gamma radiation in those areas of the Station where high radiation fields are expected; - Provides a continuous and centralized display of the radiation level in each of the monitored areas. The display shall be in exposure rate units (R/h); - Provides a visual and audible alarm in each monitored areas; Allows the control room operator to check at any time the radiation levels and alarm conditions in each of the monitored areas; - Control room operator shall be alerted of any alarm conditions that occurs in the Station. A typical monitoring loop is composed of the following components: Detector Assembly type: CI-MA - 522 two channels, two ranges; Horn and Beacon Assembly; Remote Indicating Meter with Warning Lights; Central computer; common equipment for all 40 loops. (authors)

  14. A History of Building 828, Sandia National Laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Ullrich, Rebecca

    1999-08-01

    This report documents the history of Building 828 in Sandia National Laboratories' Technical Area I. Building 828 was constructed in 1946 as a mechanical test laboratory for Los Alamos' Z-Division (later Sandia) as it moved to Sandia Base. The building has undergone significant remodeling over the years and has had a variety of occupants. The building was evaluated in compliance with the National Historic Preservation Act, but was not eligible for the National Register of Historic Places. Nevertheless, for many Labs employees, it was a symbol of Sandia's roots in World War II and the Manhattan Project.

  15. 78 FR 66375 - Announcement of Funding Awards for the OneCPD Plus: Technical Assistance and Capacity Building...

    Science.gov (United States)

    2013-11-05

    ... via TTY by calling the toll-free Federal Information Relay Service during working hours at 800-877... expert statutory, regulatory, and technical support that improves the program knowledge, skills and capacity of HUD's customers and their partners. Capacity building efforts will be directed at advancing the...

  16. TecCOMFrame : Building bridges between technical communication and translation studies through a prototype specialisation curriculum

    NARCIS (Netherlands)

    Cleary, Yvonne; Engberg, Jan; Karreman, Joyce; Meex, Birgitta; Closs, Sissi; Drazek, Zygmunt; Ghenghea, Voichita; Minacori, Patricia; Muller, J.; Straub, Daniela

    2017-01-01

    Technical communication is a new field of work compared to other professions, and therefore it does not have a standardised curriculum. In Europe, many technical communicators do not have qualifications in the area. TecCOMFrame, a project funded by the European Union, aims to develop an academic

  17. WindPACT Turbine Design Scaling Studies Technical Area 1-Composite Blades for 80- to 120-Meter Rotor

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, D.A.

    2001-04-30

    The United States Department of Energy (DOE) through the National Renewable Energy Laboratory (NREL) implemented the Wind Partnership for Advanced Component Technologies (WindPACT) program. As part of the WindPACT program, Global Energy Concepts, LLC (GEC), was awarded contract number YAM-0-30203-01 to examine Technical Area 1-Blade Scaling, Technical Area 2-Turbine Rotor and Blade Logistics, and Technical Area 3-Self-Erecting Towers. This report documents the results of GEC's Technical Area 1-Blade Scaling. The primary objectives of the Blade-Scaling Study are to assess the scaling of current materials and manufacturing technologies for blades of 40 to 60 meters in length, and to develop scaling curves of estimated cost and mass for rotor blades in that size range.

  18. Clearance of buildings for demolition: ways to clearance on the standing structure for covered surfaces and inaccessible areas

    International Nuclear Information System (INIS)

    Thraenert, S.; Riemann, T.

    2014-01-01

    In general terms, the TUV NORD Nuclear services encompass safety assessments, design reviews, documentation re-views and inspections. They reflect the full scope of a technical service provider in the nuclear field. In the domestic market, these services are provided for the regulator, whereas in the international market any party involved in a nuclear project is a potential customer of TUV NORD Nuclear. This implies that TUV NORD Nuclear is offering consultancy, engineering and inspection services. Regarding the clearance of buildings for demolition, there are two different possible ways for the radiological characterization. The first option is a characterization on the standing structure before demolition and the second option is the characterization of the building rubble after demolition. According to the German Radiation Protection Ordinance, buildings of decommissioned nuclear sites have to be preferentially cleared on the standing structure. If compliance with the surface specific clearance levels is achieved on the standing structure, usually the cleared buildings can be demolished and the resulting rubble may be used without any further radiological considerations. In the case of the former nuclear power plant Wuergassen the majority of the building rubble is scheduled to stay on site to serve as backfill for the building pit. As such a scenario was not considered in the radiological considerations of, e.g., the German Radiation Protection Ordinance, an additional dose calculation was carried out for Wuergassen NPP basing on its radiological characteristics to directly prove compliance with the de-minimis-concept. The radiation controlled area (RCA) of Wuergassen NPP comprises an area of about 140.000 m 2 . This area is more or less easily accessible to characterization and decontamination using, if necessary, scaffoldings or lifting platforms. Up to the beginning of 2013, compliance with the surface specific clearance levels was verified on the standing

  19. Technical Elements (CCT1)

    DEFF Research Database (Denmark)

    Thomsen, Kirsten Engelund; Wittchen, Kim Bjarne

    2017-01-01

    Many of the aspects dealt with in the CA EPBD are closely interlinked with each other and may refer to both new and existing buildings, as well as to inspection and certification. This is also true for technical aspects, such as the calculation methodologies, and how to include technical systems......’ efficiency or how to integrate renewable energy within them. The central team for Technical Elements deals with issues of a technical nature, which are common to new and existing buildings, and/or with minimum demands, certification and inspection. This report focuses on the implementation of Articles 3, 4...

  20. Technical development of fluid machinery area

    International Nuclear Information System (INIS)

    Chung, Kyung Nam; Kim, Jin Young; Kim, Yang Ik

    2008-01-01

    In this paper, recent research activity of Hyundai Heavy Industries in the fluid machinery area is introduced. Technical development has been carried out in pumps, turbines, construction equipment, side thrusters, engine lubrication flow, etc. Here the technology of pumps and cooling of construction equipment will be dealt with. We have actively used computational fluid dynamics in the performance analysis of pump models and the design of new models of various industrial pumps or marine pumps. And a cooling analysis system composed of 3D flow analysis and 1D cooling analysis has been established, and applied to the design of cooling systems of new models of excavators and wheel loaders. The above mentioned technology is presented in details, and some future works are mentioned

  1. Building Professional and Technical Skills in the Use of Earth Observations through the NASA DEVELOP National Program: Best Practices & Lessons Learned

    Science.gov (United States)

    Crepps, G.; Ross, K. W.; Childs-Gleason, L. M.; Allsbrook, K. N.; Rogers, L.; Ruiz, M. L.; Clayton, A.

    2017-12-01

    The NASA DEVELOP National Program offers 10-week research opportunities to participants to work on rapid feasibility projects utilizing NASA Earth observations in a variety of applications, including ecological forecasting, water resources, disasters, and health and air quality. DEVELOP offers a unique collaborative environment in which students, recent graduates, and transitioning career professionals are placed on interdisciplinary teams to conduct projects. DEVELOP offers a variety of opportunities and resources to build participants technical skills in remote sensing and GIS, as well as interpersonal and leadership skills. As a capacity building program, DEVELOP assesses participants' growth by using entrance and exit personal growth assessments, as well as gathering general program feedback through an exit survey. All of this information is fed back into the program for continual improvement. DEVELOP also offers a progression of opportunities through which participants can advance through the program, allowing participants to build a diverse set of technical and leadership skills. This presentation will explore best practices including the use of pre- and post-growth assessments, offering advanced leadership opportunities, and overall capacity building impacts on participants.

  2. Analysis of heat source selection for residential buildings in rural areas

    OpenAIRE

    Szul Tomasz

    2018-01-01

    The research aiming to check whether the output of currently installed boilers matches the use requirements together with estimation of their energy efficiency was carried out on a group of 84 single-family residential buildings located in rural areas. Heating and hot water energy needs were calculated for each building in order to determine the use requirements. This enabled verification whether the currently installed boilers match the actual use requirements in the buildings. Based on the ...

  3. Identification of Vital Areas at Nuclear Facilities. Technical Guidance (French Edition)

    International Nuclear Information System (INIS)

    2015-01-01

    The possibility that nuclear or other radioactive material could be used for malicious purposes cannot be ruled out in the current global situation. States have responded to this risk by engaging in a collective commitment to strengthen the protection and control of such material and to effectively respond to nuclear security events. States have agreed to strengthen existing and established new international legal instruments to enhance nuclear security around the world. Nuclear security is fundamental in the management of nuclear technologies and in applications where nuclear or other radioactive material is used or transported. Through its nuclear security programme, the IAEA supports States to establish, maintain and sustain an effective nuclear security regime. The IAEA has adopted a comprehensive approach to nuclear security. This recognizes that an effective national nuclear security regime builds on: the implementation of relevant international legal instruments; information protection; physical protection; material accounting and control; detection of and response to trafficking in such material; national response plans; and contingency measures. With its nuclear security series, the IAEA aims to assist States to implement and sustain such a regime in a coherent and integrated manner. The IAEA Nuclear Security Series comprises: Nuclear Security Fundamentals, which include objectives and essential elements of a State?s nuclear security regime; Recommendations; Implementing Guides; and Technical Guidance publications. Each State carries the full responsibility for nuclear security, i.e. to provide for the security of nuclear and other radioactive material and associated facilities and activities; to ensure the security of such material in use, storage or in transport; and to combat illicit trafficking and the inadvertent movement of such material. It should also be prepared to respond to a nuclear security event. The IAEA recommendations for the protection of

  4. The Components of Abstracts: the Logical Structure of Abstractsin the Area of Technical Sciences

    Directory of Open Access Journals (Sweden)

    Nina Jamar

    2014-04-01

    Full Text Available ABSTRACTPurpose: The main purpose of this research was to find out what kind of structure would be the most appropriate for abstracts in the area of technical sciences, and on the basis of these findings develop guidelines for their writing.Methodology/approach: First, the components of abstracts published in journals were analyzed. Then the prototypes and recommended improved abstracts were presented. Third, the satisfaction of the readers with the different forms of abstracts was examined. According to the results of these three parts of the research, the guidelines for writing abstracts in the area of technical sciences were developed.Results: The results showed that it is possible to determine the optimum structure for abstracts from the area of technical sciences. This structure should follow the known IMRD format or BMRC structure according to the coding scheme.Research limitations: The presented research included in the analysis only abstracts from several areas that represent technical studies. In order to develop the guidelines for writing abstracts more broadly, the research should be extended with at least one more area from the natural sciences and two areas from social sciences and humanities.Original/practical implications: It is important to emphasize that even if the guidelines for writing abstracts by the individual journal exist, authors do not always take them into account. Therefore, it is important that the abstracts that are actually published in journals were analysed. It is also important that with the development of guidelines for writing abstracts the opinion of researchers was also taken into account.

  5. Building Stronger State Energy Partnerships with the U.S. Department of Energy

    Energy Technology Data Exchange (ETDEWEB)

    Marks, Kate

    2011-09-30

    This final technical report details the results of total work efforts and progress made from October 2007 – September 2011 under the National Association of State Energy Officials (NASEO) cooperative agreement DE-FC26-07NT43264, Building Stronger State Energy Partnerships with the U.S. Department of Energy. Major topical project areas in this final report include work efforts in the following areas: Energy Assurance and Critical Infrastructure, State and Regional Technical Assistance, Regional Initiative, Regional Coordination and Technical Assistance, and International Activities in China. All required deliverables have been provided to the National Energy Technology Laboratory and DOE program officials.

  6. Healthy Buildings '88

    International Nuclear Information System (INIS)

    Berglund, B.; Lindvall, T.; Maansson, L.G.

    1988-06-01

    The Healthy Buildings '88 Conference focuses on the technical solutions and functional requirements contributing to Healthy Buildings for people to live and work in. The main object of the Conference is to give architects, consultants, real-estate owners and manufacturers of building materials recommendations on choice of materials and choice of systems and on how to combine materials and systems. The program includes overview lectures, plenary symposia with invited speakers, workshops, poster presentations and an exhibition of scientific, educational and technical material. One part of the conference is devoted to the problem of radon in residential buildings

  7. Appendix D-12A Building 332C Waste Accumulation Area

    International Nuclear Information System (INIS)

    Chase, D

    2005-01-01

    This appendix is designed to provide information specific to the Building 332C Waste Accumulation Area (B-332C WAA), a waste storage area. This appendix is not designed to be used as a sole source of information. All general information that is not specific to the B-332C WAA is included in the Contingency Plan for Waste Accumulation Areas, dated July 2004, and should be referenced. The B-332C WAA is located in the southwest quadrant of the LLNL Main Site in Building 332, Room 1330. Hazardous and mixed wastes may be stored at the B-332C WAA for 90 days or less, until transferred to the appropriate Radioactive and Hazardous Waste Management (RHWM) facility or other permitted treatment, storage or disposal facility (TSDF). Radioactive waste may also be stored at the WAA. The design storage capacity of this WAA is 2,200 gallons

  8. Technical Support Document: Development of the Advanced Energy Design Guide for Medium to Big Box Retail Buildings - 50% Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Bonnema, Eric [National Renewable Energy Lab. (NREL), Golden, CO (United States); Leach, Matt [National Renewable Energy Lab. (NREL), Golden, CO (United States); Pless, Shanti [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-06-05

    This Technical Support Document describes the process and methodology for the development of the Advanced Energy Design Guide for Medium to Big Box Retail Buildings: Achieving 50% Energy Savings Toward a Net Zero Energy Building (AEDG-MBBR) ASHRAE et al. (2011b). The AEDG-MBBR is intended to provide recommendations for achieving 50% whole-building energy savings in retail stores over levels achieved by following ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings (Standard 90.1-2004) (ASHRAE 2004b). The AEDG-MBBR was developed in collaboration with the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), the American Institute of Architects (AIA), the Illuminating Engineering Society of North America (IES), the U.S. Green Building Council (USGBC), and the U.S. Department of Energy.

  9. Technical Support Document: Development of the Advanced Energy Design Guide for Medium to Big Box Retail Buildings - 50% Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Bonnema, E.; Leach, M.; Pless, S.

    2013-06-01

    This Technical Support Document describes the process and methodology for the development of the Advanced Energy Design Guide for Medium to Big Box Retail Buildings: Achieving 50% Energy Savings Toward a Net Zero Energy Building (AEDG-MBBR) ASHRAE et al. (2011b). The AEDG-MBBR is intended to provide recommendations for achieving 50% whole-building energy savings in retail stores over levels achieved by following ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings (Standard 90.1-2004) (ASHRAE 2004b). The AEDG-MBBR was developed in collaboration with the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), the American Institute of Architects (AIA), the Illuminating Engineering Society of North America (IES), the U.S. Green Building Council (USGBC), and the U.S. Department of Energy.

  10. ORGANIZATIONAL STRUCTURE FOR BUILDINGS RECONSTRUCTION OF HISTORICAL BUILDING OF ODESSA

    Directory of Open Access Journals (Sweden)

    POSTERNAK I. М.

    2016-12-01

    Full Text Available Formulation of the problem. As one of perspective forms of integration various complexes act in town-planning structure. In the course of formation of plans of social and economic development of large cities even more often there is a situation when for increase of efficiency of used resources concentration of efforts is necessary not simply, but also new progressive forms of the organization of building manufacture. Purpose. To offer the organizational structure using in practice the saved up scientific and technical potential for reconstruction of buildings of historical building of Odessa 1820 … 1920 years under standards power efficiency and to execute researches engineering architectonics residential buildings of historical building of a city of Odessa. Conclusion. It is offered to create in the city of Odessa "the Corporate scientific and technical complex town-planning power reconstruction "CSTC T-PPR", as innovative organizational structure which uses in practice the saved up scientific and technical potential for reconstruction of buildings of historical building of Odessa under standards power efficiency. It is considered engineering architectonics residential buildings of historical building of a city of Odessa, in particular, not looking on diverse buildings of inhabited appointment of Odessa, for them there are defining factors on which probably to make their grouping and at the same time to allocate the general lines inherent to a housing estate as a whole. It is resulted a general characteristic and classification of residential buildings of historical building of a city of Odessa ХІХ … beginnings ХХ centuries It is allocated and expanded classification of such buildings of inhabited appointment by duration of residing at them.

  11. ORGANIZATIONAL STRUCTURE FOR RECONSTRUCTION OF BUILDINGS HISTORICAL BUILDING OF ODESSA

    Directory of Open Access Journals (Sweden)

    POSTERNAK I. М.

    2017-05-01

    Full Text Available Summary. Raising of problem. As one of perspective forms of integration various complexes act in town- planning structure. In the course of formation of plans of social and economic development of large cities even more often there is a situation when for increase of efficiency of used resources concentration of efforts is necessary not simply, but also new progressive forms of the organization of building manufacture. Purpose. To offer the organizational structure using in practice the saved up scientific and technical potential for reconstruction of buildings of historical building of Odessa 1820 … 1920 years under standards power efficiency and to execute researches engineering architectonics residential buildings of historical building of a city of Odessa. Conclusion. It is offered to create in the city of Odessa "the Corporate scientific and technical complex town-planning power reconstruction "CSTC T-PPR", as innovative organizational structure which uses in practice the saved up scientific and technical potential for reconstruction of buildings of historical building of Odessa under standards power efficiency. It is considered engineering architectonics residential buildings of historical building of a city of Odessa, in particular, not looking on diverse buildings of inhabited appointment of Odessa, for them there are defining factors on which probably to make their grouping and at the same time to allocate the general lines inherent to a housing estate as a whole. It is resulted a general characteristic and classification of residential buildings of historical building of a city of Odessa ХІХ beginnings ХХ centuries It is allocated and expanded classification of such buildings of inhabited appointment by duration of residing at them.

  12. Technical Area 55 Entry Control System (ECS)

    International Nuclear Information System (INIS)

    Beaumont, A.; Brundige, E.; DesJardin, R.; Rivera, R.

    1984-01-01

    The exchange badge system which was used at the Plutonium Facility located in Technical Area 55 was replaced on a trial basis with an automated Entry Control System. As a result of the success of the trial system, a new system incorporating expanded features and increased reliability is being implemented. The new Entry Control System incorporates several features not previously available in relatively inexpensive entry systems. The reliability of the system is enhanced by redundant microprocessors incorporating bubble memory for nonvolatile storage of the system data base. The badge readers incorporate dual communication lines to two different controllers to further increase the total system reliability

  13. 100-D Area technical baseline report

    International Nuclear Information System (INIS)

    Carpenter, R.W.

    1993-01-01

    This document is prepared in support of the 100 Area Environmental Restoration activity at the US Department of Energy's Hanford Site near Richland, Washington. It provides a technical baseline of waste sites located at the 100-D Area. The report is based on an environmental investigation undertaken by the Westinghouse Hanford Company (WHC) History Office in support of the Environmental Restoration Engineering Function and on review and evaluation of numerous Hanford Site current and historical reports, drawings, and photographs, supplemented by site inspections and employee interviews. No intrusive field investigation or sampling was conducted. All Hanford coordinate locations are approximate locations taken from several different maps and drawings of the 100-D Area. Every effort was made to derive coordinate locations for the center of each facility or waste site, except where noted, using standard measuring devices. Units of measure are shown as they appear in reference documents. The 100-D Area is made up of three operable units: 100-DR-1, 100-DR-2, and 100-DR-3. All three are addressed in this report. These operable units include liquid and solid waste disposal sites in the vicinity of, and related to, the 100-D and 100-DR Reactors. A fourth operable unit, 100-HR-3, is concerned with groundwater and is not addressed here. This report describes waste sites which include cribs, trenches, pits, french drains, retention basins, solid waste burial grounds, septic tanks, and drain fields. Each waste site is described separately and photographs are provided where available. A complete list of photographs can be found in Appendix A. A comprehensive environmental summary is not provided here but may be found in Hanford Site National Environmental Policy Act Characterization (Cushing 1988), which describes the geology and soils, meteorology, hydrology, land use, population, and air quality of the area

  14. Modeling of technical soil-erosion control measures and its impact on soil erosion off-site effects within urban areas

    Science.gov (United States)

    Dostal, Tomas; Devaty, Jan

    2013-04-01

    The paper presents results of surface runoff, soil erosion and sediment transport modeling using Erosion 3D software - physically based mathematical simulation model, event oriented, fully distributed. Various methods to simulate technical soil-erosion conservation measures were tested, using alternative digital elevation models of different precision and resolution. Ditches and baulks were simulated by three different approaches, (i) by change of the land-cover parameters to increase infiltration and decrease flow velocity, (ii) by change of the land-cover parameters to completely infiltrate the surface runoff and (iii) by adjusting the height of the digital elevation model by "burning in" the channels of the ditches. Results show advantages and disadvantages of each approach and conclude suitable methods for combinations of particular digital elevation model and purpose of the simulations. Further on a set of simulations was carried out to model situations before and after technical soil-erosion conservation measures application within a small catchment of 4 km2. These simulations were focused on quantitative and qualitative assessment of technical soil-erosion control measures impact on soil erosion off-site effects within urban areas located downstream of intensively used agricultural fields. The scenarios were built upon a raster digital elevation model with spatial resolution of 3 meters derived from LiDAR 5G vector point elevation data. Use of this high-resolution elevation model allowed simulating the technical soil-erosion control measures by direct terrain elevation adjustment. Also the structures within the settlements were emulated by direct change in the elevation of the terrain model. The buildings were lifted up to simulate complicated flow behavior of the surface runoff within urban areas, using approach of Arévalo (Arévalo, 2011) but focusing on the use of commonly available data without extensive detailed editing. Application of the technical

  15. Technical Evaluation of Soil Remediation Alternatives at the Building 812 Operable Unit, Lawrence Livermore National Laboratory Site 300

    International Nuclear Information System (INIS)

    Eddy-Dilek, C.; Miles, D.; Abitz, R.

    2009-01-01

    The Department of Energy Livermore Site Office requested a technical review of remedial alternatives proposed for the Building 812 Operable Unit, Site 300 at the Lawrence Livermore National Laboratory. The team visited the site and reviewed the alternatives proposed for soil remediation in the draft RI/FS and made the following observations and recommendations. Based on the current information available for the site, the team did not identify a single technology that would be cost effective and/or ecologically sound to remediate DU contamination at Building 812 to current remedial goals. Soil washing is not a viable alternative and should not be considered at the site unless final remediation levels can be negotiated to significantly higher levels. This recommendation is based on the results of soil washing treatability studies at Fernald and Ashtabula that suggest that the technology would only be effective to address final remediation levels higher than 50 pCi/g. The technical review team identified four areas of technical uncertainty that should be resolved before the final selection of a preferred remedial strategy is made. Areas of significant technical uncertainty that should be addressed include: (1) Better delineation of the spatial distribution of surface contamination and the vertical distribution of subsurface contamination in the area of the firing table and associated alluvial deposits; (2) Chemical and physical characterization of residual depleted uranium (DU) at the site; (3) Determination of actual contaminant concentrations in air particulates to support risk modeling; and (4) More realistic estimation of cost for remedial alternatives, including soil washing, that were derived primarily from vendor estimates. Instead of conducting the planned soil washing treatability study, the team recommends that the site consider a new phased approach that combines additional characterization approaches and technologies to address the technical uncertainty in

  16. TECHNICAL EVALUATION OF SOIL REMEDIATION ALTERNATIVES AT THE BUILDING 812 OPERABLE UNIT, LAWRENCE LIVERMORE NATIONAL LABORATORY SITE 300

    Energy Technology Data Exchange (ETDEWEB)

    Eddy-Dilek, C.; Miles, D.; Abitz, R.

    2009-08-14

    The Department of Energy Livermore Site Office requested a technical review of remedial alternatives proposed for the Building 812 Operable Unit, Site 300 at the Lawrence Livermore National Laboratory. The team visited the site and reviewed the alternatives proposed for soil remediation in the draft RI/FS and made the following observations and recommendations. Based on the current information available for the site, the team did not identify a single technology that would be cost effective and/or ecologically sound to remediate DU contamination at Building 812 to current remedial goals. Soil washing is not a viable alternative and should not be considered at the site unless final remediation levels can be negotiated to significantly higher levels. This recommendation is based on the results of soil washing treatability studies at Fernald and Ashtabula that suggest that the technology would only be effective to address final remediation levels higher than 50 pCi/g. The technical review team identified four areas of technical uncertainty that should be resolved before the final selection of a preferred remedial strategy is made. Areas of significant technical uncertainty that should be addressed include: (1) Better delineation of the spatial distribution of surface contamination and the vertical distribution of subsurface contamination in the area of the firing table and associated alluvial deposits; (2) Chemical and physical characterization of residual depleted uranium (DU) at the site; (3) Determination of actual contaminant concentrations in air particulates to support risk modeling; and (4) More realistic estimation of cost for remedial alternatives, including soil washing, that were derived primarily from vendor estimates. Instead of conducting the planned soil washing treatability study, the team recommends that the site consider a new phased approach that combines additional characterization approaches and technologies to address the technical uncertainty in

  17. Sustainable Building Life Cycle Design

    Directory of Open Access Journals (Sweden)

    Ginzburg Alexander

    2016-01-01

    Full Text Available The current building life cycle management system in the Russian Federation is a family of discrete subsystems that exist independently for different building life cycle stages. In this situation building reliability and sustainable functioning are out of the question. The implementation of a united information model (BIM-model intended to describe building entire life cycle will allow to raise the sustainability, but this will happen only if goals and concerns of all participants of the project process are properly coordinated. An important figure of process sustainability is the organizational and technological reliability (OTR that describes the possibility of a system to reach a goal. In case of building life cycle design, the economical efficiency of a building can be considered as the goal. The required technical, ecological, organizational, and other parameters form a complex of constraints that determine the area of allowable values for building functioning. In its broad meaning, OTR may be understood as the probability of receiving an economical effect based on the value of organizational and economical reliability (OER.

  18. Radon concentrations inside public and commercial buildings in the Pittsburgh area

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, B L; Kulwicki, D R; Warner, Jr, K R; Grassi, C L

    1984-09-01

    Radon concentrations in ambient air from numerous schools, stores and other public and commercial buildings in the Pittsburgh, PA, area were measured by grab sampling. This is more appropriate than using long-term integrating monitors because of the correlation between times of occupancy and Rn levels. Results indicate that Rn concentrations in these buildings are nearly an order of magnitude less than in homes, and not much higher than outdoors. Variations among sites is also much less than for homes, probably because there is less variability in ventilation and building maintenance practices. Colleges and universities have somewhat higher Rn levels and a larger degree of variability than commercial buildings or hospitals. There was no indication of higher Rn levels in cold weather than in warm weather, or of correlations with the age of the building.

  19. Radon concentrations inside public and commercial buildings in the Pittsburgh area.

    Science.gov (United States)

    Cohen, B L; Kulwicki, D R; Warner, K R; Grassi, C L

    1984-09-01

    Radon concentrations in ambient air from numerous schools, stores and other public and commercial buildings in the Pittsburgh, PA, area were measured by grab sampling. This is more appropriate than using long-term integrating monitors because of the correlation between times of occupancy and Rn levels. Results indicate that Rn concentrations in these buildings are nearly an order of magnitude less than in homes, and not much higher than outdoors. Variations among sites is also much less than for homes, probably because there is less variability in ventilation and building maintenance practices. Colleges and universities have somewhat higher Rn levels and a larger degree of variability than commercial buildings or hospitals. There was no indication of higher Rn levels in cold weather than in warm weather, or of correlations with the age of the building.

  20. Electrical Switchgear Building No. 5010-ESF Fire Hazards Technical Report

    International Nuclear Information System (INIS)

    N.M. Ruonavaara

    2001-01-01

    The purpose of this Fire Hazards Analysis Technical Report (hereinafter referred to as Technical Report) is to assess the risk from fire within individual fire areas to ascertain whether the U.S. Department of Energy (DOE) fire safety objectives are met. The objectives, identified in DOE Order 420.1, Change 2, Fire Safety, Section 4.2, establish requirements for a comprehensive fire and related hazards protection program for facilities sufficient to minimize the potential for: (1) The occurrence of a fire or related event; (2) A fire that causes an unacceptable on-site or off-site release of hazardous or radiological material that will threaten the health and safety of the employees, the public, and the environment; (3) Vital DOE programs suffering unacceptable interruptions as a result of fire and related hazards; (4) Property losses from a fire and related events exceeding defined limits established by DOE; and (5) Critical process controls and safety class systems being damaged as a result of a fire and related event

  1. Importance of determination of the radon risk of the area for building before the building of every stay building

    International Nuclear Information System (INIS)

    Pinter, I.; Vicanova, M.

    1997-01-01

    In this paper the authors are dilating with the analyse of the equivalent volume activity of the radon in the flat's spaces and of the geological environment in the Slovak Republic. Nevertheless, that for the time being it is not explicitly legislative determined obligation of the discovering of the radon risk of the area of the planned housing, the the ends from up to now realized researches corroborate us the relevance of the quoted problem on the area of the Slovak Republic and the necessity of the determination of the radon risk of the area of the housing of the every inhabitable building [sk

  2. Annual Report for Los Alamos National Laboratory Technical Area 54, Area G Disposal Facility - Fiscal Year 2016

    Energy Technology Data Exchange (ETDEWEB)

    Birdsell, Kay Hanson [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Stauffer, Philip H. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Atchley, Adam Lee [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Miller, Elizabeth D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chu, Shaoping [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); French, Sean B. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-24

    As a condition to the disposal authorization statement issued to Los Alamos National Laboratory (LANL or the Laboratory) on March 17, 2010, a comprehensive performance assessment and composite analysis (PA/CA) maintenance program must be implemented for the Technical Area 54, Area G disposal facility. Annual determinations of the adequacy of the PA/CA are to be conducted under the maintenance program to ensure that the conclusions reached by those analyses continue to be valid. This report summarizes the results of the fiscal year (FY) 2016 annual review for Area G.

  3. Technical Support Document: Development of the Advanced Energy Design Guide for Small Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Jarnagin, Ronald E.; Liu, Bing; Winiarski, David W.; McBride, Merle F.; Suharli, L.; Walden, D.

    2006-11-30

    This Technical Support Document (TSD) describes the process and methodology for the development of the Advanced Energy Design Guide for Small Office Buildings (AEDG-SO), a design guidance document intended to provide recommendations for achieving 30% energy savings in small office buildings over levels contained in ANSI/ASHRAE/IESNA Standard 90.1-1999, Energy Standard for Buildings Except Low-Rise Residential Buildings. The AEDG-SO is the first in a series of guides being developed by a partnership of organizations, including the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (ASHRAE), the American Institute of Architects (AIA), the Illuminating Engineering Society of North America (IESNA), the New Buildings Institute (NBI), and the U.S. Department of Energy (DOE). Each of the guides in the AEDG series will provide recommendations and user-friendly design assistance to designers, developers and owners of small commercial buildings that will encourage steady progress towards net-zero energy buildings. The guides will provide prescriptive recommendation packages that are capable of reaching the energy savings target for each climate zone in order to ease the burden of the design and construction of energy-efficient small commercial buildings The AEDG-SO was developed by an ASHRAE Special Project committee (SP-102) made up of representatives of each of the partner organizations in eight months. This TSD describes the charge given to the committee in developing the office guide and outlines the schedule of the development effort. The project committee developed two prototype office buildings (5,000 ft2 frame building and 20,000 ft2 two-story mass building) to represent the class of small office buildings and performed an energy simulation scoping study to determine the preliminary levels of efficiency necessary to meet the energy savings target. The simulation approach used by the project committee is documented in this TSD along with

  4. A New Method of Technical Analysis to Optimise the Design of Low Impact Energy Systems for Buildings

    Directory of Open Access Journals (Sweden)

    Roberto De Lieto Vollaro

    2013-10-01

    Full Text Available Energy consumption for civil constructions represents about 40% of total energy requirements, so it is necessary to achieve the goal of energy savings and the consequent reduction of greenhouse gases emissions. The study in content aims to provide a design methodology enables to identify the best plant configuration for buildings from a technical, economic and environmental point of view. To assess validity of the calculation model, an analysis of an historical building was carried out in combination with two softwares of proven reliability: TRNSYS, used to evaluate the thermal demand of users, and RETScreen, used to estimate the validity of the chosen energy model.

  5. Electromagnetic terrorism – threats in buildings

    Directory of Open Access Journals (Sweden)

    Marek Kuchta

    2015-06-01

    Full Text Available The paper presents the impact of electromagnetic pulses (high power and high frequency pulses — weapon E on technical infrastructure of buildings [1]. The use of modern technologies in intelligent building management i.e. human resources, control and automation systems, efficient buildings space management, requires using a large number of integrated electronic systems. From technical point of view, the intelligent building is a building in which all subsystems (e.g. technical security, air conditioning, ventilation, lighting, power, electricity, etc., interact with each other and create human-friendly environment. The use of specialized electronic systems, processors, microcontrollers in these subsystems may be a trigger of the use of weapons E as an alternative of terrorist attack— disabling automatic building management systems.[b]Keywords[/b]: electromagnetic weapons, distortion, sensitivity, susceptibility

  6. Technical Targets - A Tool to Support Strategic Planning in the Subsurface Contaminants Focus Area

    International Nuclear Information System (INIS)

    Looney, B.B.

    2002-01-01

    The Subsurface Contaminants Focus Area (SCFA) is supported by a lead laboratory consisting of technical representatives from DOE laboratories across the country. This broadly representative scientific group has developed and implemented a process to define Technical Targets to assist the SCFA in strategic planning and in managing their environmental research and development portfolio. At an initial meeting in Golden Colorado, an initial set of Technical Targets was identified using a rapid consensus based technical triage process. Thirteen Technical Targets were identified and described. Vital scientific and technical objectives were generated for each target. The targets generally fall into one of the following five strategic investment categories: Enhancing Environmental Stewardship, Eliminating Contaminant Sources, Isolating Contaminants, Controlling Contaminant Plumes, Enabling DOEs CleanUp Efforts. The resulting targets and the detail they comprise on what is, and what is not, needed to meet Environmental Management needs provide a comprehensive technically-based framework to assist in prioritizing future work and in managing the SCFA program

  7. 100 Area D4 Project Building Completion Report: December 2008 to December 2009

    International Nuclear Information System (INIS)

    Finucane, K.G.; Harrie, J.P.

    2010-01-01

    This report documents the final status of buildings after the completion of D4 activities at the 100 Area of the U.S. Department of Energy Hanford Site from December 1, 2008, to December 31, 2009. The following buildings are included in this report: 11-N Change Room; 13-N Storage Building; 107-N Basin Recirculation Facility; 108-N Chemical Unloading Facility; 183-ND Resin Disposal Pit; 183-F Clearwells; 188-D Ash Disposal Pit; 1524-N Hazardous Waste Storage Pad; 1525-N Laydown Storage Area; 1607-Ni Sewage Tank; 1607-N2 Sewage Tank; 1706-NA Sewage Lift Station; 1904-D Outfall Structure; MO-013 Mobile Office Trailer; MO-422 Mobile Office Trailer; and MO-999 Mobile Office Trailer. Demolition debris and soil associated with completion of these buildings were disposed at the Environmental Restoration Disposal Facility (ERDF), located at the Hanford Site. Postdemolition direct hand instrument surveys and Global Positioning Environmental Radiological Survey (GPERS) surveys were performed on excavations after loadout of debris and prior to backfill. The 100 Area D4/Interim Safe Storage (ISS) project personnel worked a total of approximately 137,930 hours (manual and non-manual, not including subcontractors) from December 1, 2008, to December 31, 2009. During this time there were 10 Occupational Safety and Health Administration (OSHA) recordable injuries, two of which involved lost time. There also were 27 first aid cases during this time period. No clothing contamination and no skin contamination incidents occurred during demolition of the 100 Area buildings. Workers received 7,350.2 person-mrem of radiological exposure from December 1, 2008, to December 31, 2009 during their support of D4 activities associated with the buildings discussed in this report. All boundary air sample results were below procedural action levels for the duration of the work performed.

  8. Unintended anchors: Building rating systems and energy performance goals for U.S. buildings

    International Nuclear Information System (INIS)

    Klotz, Leidy; Mack, Daniel; Klapthor, Brent; Tunstall, Casey; Harrison, Jennilee

    2010-01-01

    In the U.S., where buildings account for 40% of energy use, commercial buildings use more energy per unit area than ever before. However, exemplary buildings demonstrate the feasibility of much better energy performance at no additional first cost. This research examines one possible explanation for this inconsistency. The aim is to investigate whether the anchoring bias, which refers to our tendency to gravitate towards a pre-defined standard regardless of its relevance, influences energy performance goals in building design. The scope examines professionals who help set energy performance goals for U.S. buildings. Prior to being asked to set an energy performance goal, these professionals were randomly directed to one of three series of questions. One series set an anchor of 90% energy reduction beyond standard practice, one set a 30% anchor, and one set no anchor. Respondents exposed to the 90% anchor, and respondents exposed to no anchor at all, set higher energy performance goals than respondents exposed to the 30% anchor. These results suggest that building rating systems that only reward incremental energy improvements may inadvertently create anchors, thereby discouraging more advanced energy performance goals and inhibiting energy performance that is technically and economically feasible.

  9. Energy-efficient building - Deficits in higher education

    International Nuclear Information System (INIS)

    Lang, T.; Messmer, R.; Kunz, M.

    2005-01-01

    This report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that examined the courses of study offered by Swiss Universities of Applied Science and the Federal Institutes of Technology that are concerned with the use of energy in the building area. The results of the survey are presented and commented on. The authors are of the opinion that basic courses of study fulfil their task of knowledge-transfer in the areas concerning energy, ecology, environment and sustainability, although the educational structures used are complex. The importance of interdisciplinary work is stressed. The focus of knowledge-transfer on persons under 40 years of age is criticised as well as deficits in interdisciplinary teamwork. The authors recommend the setting-up of further education programmes for older architects and professionals in the building technical services area

  10. Predictors of employer satisfaction: technical and non-technical skills.

    Science.gov (United States)

    Danielson, Jared A; Wu, Tsui-Feng; Fales-Williams, Amanda J; Kirk, Ryan A; Preast, Vanessa A

    2012-01-01

    Employers of 2007-2009 graduates from Iowa State University College of Veterinary Medicine were asked to respond to a survey regarding their overall satisfaction with their new employees as well as their new employees' preparation in several technical and non-technical skill areas. Seventy-five responses contained complete data and were used in the analysis. Four technical skill areas (data collection, data interpretation, planning, and taking action) and five non-technical skill areas (interpersonal skills, ability to deal with legal issues, business skills, making referrals, and problem solving) were identified. All of the skill area subscales listed above had appropriate reliability (Cronbach's alpha>0.70) and were positively and significantly correlated with overall employer satisfaction. Results of two simultaneous regression analyses indicated that of the four technical skill areas, taking action is the most salient predictor of employer satisfaction. Of the five non-technical skill areas, interpersonal skills, business skills, making referrals, and problem solving were the most important skills in predicting employer satisfaction. Hierarchical regression analysis revealed that all technical skills explained 25% of the variation in employer satisfaction; non-technical skills explained an additional 42% of the variation in employer satisfaction.

  11. Building control. Technical building systems: Automation and management; Building Control. Technische Gebaeudesysteme: Automation und Bewirtschaftung

    Energy Technology Data Exchange (ETDEWEB)

    Kranz, H.R.; Baenninger, M.; Bieler, P.; Brettschneider, J.P.; Damnig, A.; Fassbender, H.W.; Friedrichs, K.; Gauchel, J.; Hegewald, B.; Kaelin, W.; Lezius, A.; Markert, H.; Oehler, A.; Otto, J.; Puettmer, M. Jr.; Rohrbacher, H.; Schuerdt, K.; Vogt, D.; Wittling, J.

    1995-12-31

    Cost-optimised management and maintenance of buildings can no longer be carried out without electronic data processing. The present anthology gives a comprehensive overview of the planning and operation of building automation systems. The following topics are discussed: ecological cooling and facade concepts, facility management, jeopardy alarm technology, building automation, communication technology, open communication and networks, building system technology, norms and directives, building right and law. A special abstract has been prepared for each of the 23 chapters. (BWI). 260 figs., 161 refs. [Deutsch] Kostenoptimiertes Management, Bewirtschaftung und Instandhaltung von Gebaeuden sind ohne EDV nicht mehr denkbar. Das vorliegende Buch gibt einen umfassenden Ueberblick ueber Planung und Betrieb von Gebaeudeautomationssystemen. Es wird dabei auf folgende Themenkomplexe eingegangen: Oekologische Kuehl- und Fassadenkonzepte; Facility Management, Gefahrenmeldetechnik, Gebaeudeautomation; Kommunikationstechnik, offenen Kommunikation und Netzwerke; Gebaeudesystemtechnik und Installationsbus; Energiemanagement; Betreibererfahrungen; Normen und Richtlinien; Baurecht und Gesetz. Fuer alle 23 Einzelkapitel wurde eine gesonderte inhaltliche Erschliessung durchgefuehrt. (BWI)

  12. PUREX Plant aggregate area management study technical baseline report

    International Nuclear Information System (INIS)

    DeFord, D.H.; Carpenter, R.W.

    1995-05-01

    The PUREX aggregate area is made up of six operable units; 200-PO-1 through 200-PO-6 and consists of liquid and solid waste disposal sites in the vicinity of, and related to, PUREX Plant operations. This report describes PUREX and its waste sites, including cribs, french drains, septic tanks and drain fields, trenches and ditches, ponds, catch tanks, settling tanks, diversion boxes, underground tank farms, and the lines and encasements that connect them. Each waste site in the aggregate area is described separately. Close relationships between waste units, such as overflow from one to another, are also discussed. This document provides a technical baseline of the aggregate area and results from an environmental investigation. This document is based upon review and evaluation of numerous Hanford Site current and historical reports, drawings and photographs, supplemented with site inspections and employee interviews. No intrusive field investigations or sampling were conducted

  13. Final Technical Report. Training in Building Audit Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Brosemer, Kathleen [Sault Sainte Marie Tribe of Chippewa Indians, Marie, MI (United States)

    2015-03-27

    In 2011, the Tribe proposed and was awarded the Training in Building Audit Technologies grant from the DOE in the amount of $55,748 to contract for training programs for infrared cameras, blower door technology applications and building systems. The coursework consisted of; Infrared Camera Training: Level I - Thermal Imaging for Energy Audits; Blower Door Analysis and Building-As-A-System Training, Building Performance Institute (BPI) Building Analyst; Building Envelope Training, Building Performance Institute (BPI) Envelope Professional; and Audit/JobFLEX Tablet Software. Competitive procurement of the training contractor resulted in lower costs, allowing the Tribe to request and receive DOE approval to additionally purchase energy audit equipment and contract for residential energy audits of 25 low-income Tribal Housing units. Sault Tribe personnel received field training to supplement the classroom instruction on proper use of the energy audit equipment. Field experience was provided through the second DOE energy audits grant, allowing Sault Tribe personnel to join the contractor, Building Science Academy, in conducting 25 residential energy audits of low-income Tribal Housing units.

  14. Technical Analysis of Combined Solar Water Heating Systems for Cold Climate Regions

    OpenAIRE

    Hossein Lotfizadeh; André McDonald; Amit Kumar

    2016-01-01

    Renewable energy resources, which can supplement space and water heating for residential buildings, can have a noticeable impact on natural gas consumption and air pollution. This study considers a technical analysis of a combined solar water heating system with evacuated tube solar collectors for different solar coverage, ranging from 20% to 100% of the total roof area of a typical residential building located in Edmonton, Alberta, Canada. The alternative heating systems were conventional (n...

  15. Sources of transportation expertise by selected technical areas

    International Nuclear Information System (INIS)

    1987-01-01

    The US Department of Energy (DOE), Office of Civilian Radioactive Waste Management (OCRWM) has assigned components of its Waste Transportation Program to three of the DOE Operations offices. The DOE Oak Ridge Operations Office (ORO) is responsible for the transportation operations design, development, acquisition, testing, implementation, and program management, including the equipment, facilities, and services of the transportation system. Within ORO, the OCRWM transportation component is assigned to the Transportation Operations Project Office (TOPO). The specific activities involved in the ORO/TOPO include procurement, operational testing, inspection, logistics, interfaces, maintenance, management and improvements, and system operation. Oak Ridge Associated Universities (ORAU) has developed (and will maintain and enhance) a data base of sources of transportation expertise in selected technical areas for ORO. The data base includes individuals and organizations who have indicated that they have capabilities and interest in assisting ORO in the design, development, implementation, and management of the OCRWM transportation system. This assistance might be in the form of consulting or subcontract work and/or participation in peer review panels, technical evaluation committees, workshops, advisory groups, etc. This initial project was completed in the four month period of January 30, 1987 through May 31, 1987

  16. Annual Report for Los Alamos National Laboratory Technical Area 54, Area G Disposal Facility – Fiscal Year 2015

    Energy Technology Data Exchange (ETDEWEB)

    French, Sean B. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Stauffer, Philip H. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Birdsell, Kay H. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-02-29

    As a condition to the disposal authorization statement issued to Los Alamos National Laboratory (LANL or the Laboratory) on March 17, 2010, a comprehensive performance assessment and composite analysis maintenance program must be implemented for the Technical Area 54, Area G disposal facility. Annual determinations of the adequacy of the performance assessment and composite analysis (PA/CA) are to be conducted under the maintenance program to ensure that the conclusions reached by those analyses continue to be valid. This report summarizes the results of the fiscal year (FY) 2015 annual review for Area G.

  17. Polychlorinated biphenyls in the exterior caulk of San Francisco Bay Area buildings, California, USA.

    Science.gov (United States)

    Klosterhaus, Susan; McKee, Lester J; Yee, Donald; Kass, Jamie M; Wong, Adam

    2014-05-01

    Extensive evidence of the adverse impacts of polychlorinated biphenyls (PCBs) to wildlife, domestic animals, and humans has now been documented for over 40 years. Despite the ban on production and new use of PCBs in the United States in 1979, a number of fish consumption advisories remain in effect, and there remains considerable uncertainty regarding ongoing environmental sources and management alternatives. Using a blind sampling approach, 25 caulk samples were collected from the exterior of ten buildings in the San Francisco Bay Area and analyzed for PCBs using congener-specific gas chromatography-mass spectrometry (GC-MS) and chlorine using portable X-ray fluorescence (XRF). PCBs were detected in 88% of the caulk samples collected from the study area buildings, with 40% exceeding 50 ppm. Detectable PCB concentrations ranged from 1 to 220,000 ppm. These data are consistent with previous studies in other cities that have identified relatively high concentrations of PCBs in concrete and masonry buildings built between 1950 and 1980. Portable XRF was not a good predictor of the PCB content in caulk and the results indicate that portable XRF analysis may only be useful for identifying caulk that contains low concentrations of Cl (≤ 10,000 ppm) and by extension low or no PCBs. A geographic information system-based approach was used to estimate that 10,500 kg of PCBs remain in interior and exterior caulk in buildings located in the study area, which equates to an average of 4.7 kg PCBs per building. The presence of high concentrations in the exterior caulk of currently standing buildings suggests that building caulk may be an ongoing source of PCBs to the San Francisco Bay Area environment. Further studies to expand the currently small international dataset on PCBs in caulking materials in buildings of countries that produced or imported PCBs appear justified in the context of both human health and possible ongoing environmental release. Copyright © 2014 Elsevier

  18. Building adaptive capacity for flood proofing in urban areas through synergistic interventions

    NARCIS (Netherlands)

    Veerbeek, W.; Ashley, R.M.; Zevenbergen, C.; Rijke, J.S.; Gersonius, B.

    2010-01-01

    Few, if any urban areas are nowadays built in isolation from existing developments. Therefore, urban expansion and making existing urban areas more sustainable is a contemporary goal. There are major opportunities to do this through the ‘normal’ renewal of urban infrastructure and building stocks

  19. Buildings-to-Grid Technical Opportunities: From the Buildings Perspective

    Energy Technology Data Exchange (ETDEWEB)

    Kiliccote, Sila [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Piette, Mary Ann [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-03-28

    This paper describes technologies and systems needed to transform buildings from the current state of siloed resources into transparent, reliable resources that participate in and benefit from an integrated "transactive energy" system.

  20. Technical Support Essentials Advice to Succeed in Technical Support

    CERN Document Server

    Sanchez, Andrew

    2010-01-01

    Technical Support Essentials is a book about the many facets of technical support. It attempts to provide a wide array of topics to serve as points of improvement, discussion, or simply topics that you might want to learn. The topics range from good work habits to the way technical supportgroups establish their own style of work. This book applies theories, models, and concepts synthesized from existing research in other fields-such as management, economics, leadership, and psychology-and connects them to technical support. The goal is to build on the work of others and allow their success to

  1. B Plant aggregate area management study technical baseline report

    International Nuclear Information System (INIS)

    DeFord, D.H.; Carpenter, R.W.

    1995-05-01

    The B aggregate area is made up of 13 operable units; 200-BP 1 through 200-BP 1 1, 200-IU-6, and 200-SS-1 that consist of liquid and solid waste disposal sites in the vicinity of, and related to, B Plant operations. This report describes B Plant and its waste sites, including cribs, french drains, septic tanks and drain fields, trenches and ditches, ponds, catch tanks, settling tanks, diversion boxes, underground tank farms designed for high-level liquid wastes, and the lines and encasements that connect them. Each waste site in the aggregate area is described separately. Close relationships between waste units, such as overflow from one to another, are also discussed. This document provides a technical baseline of the aggregate area and results from an environmental investigation. This document is based upon review and evaluation of numerous Hanford Site current and historical reports, drawings and photographs, supplemented with site inspections and employee interviews. No intrusive field investigations or sampling were conducted

  2. Large scale rooftop photovoltaics grid connected system at Charoenphol-Rama I green building

    Energy Technology Data Exchange (ETDEWEB)

    Ketjoy, N.; Rakwichian, W. [School of Renewable Energy Technology (SERT) (Thailand); Wongchupan, V. [Panya Consultants Co., Ltd (Thailand); Sankarat, T. [Tesco Lotus, Ek-Chai Distribution System Co., Ltd. (Thailand)

    2004-07-01

    This paper presents a technical feasibility study project for the large scale rooftop photovoltaics (PV) grid connected system at Charoenphol-Rama I green building super store of TESCO LOTUS (TL) in Thailand. The objective of this project is (i) to study the technical feasibility of installation 350 kWp PV systems on the top of the roof in this site (ii) and to determine the energy produce from this system. The technical factors are examined using a computerized PVS 2000 simulation and assessment tool. This super store building located in Bangkok, with latitude 14 N, longitude 100 E and the building direction is 16 from North direction. The building roof area is 14,000 m2; with 3 degree face East and 3 degree face West pitch. Average daily solar energy in this area is approximately 5.0 kWh. The study team for this project consists of educational institution as School of Renewable Energy Technology (SERT) and private institution as Panya Consultants (PC). TL is the project owner, PC is responsible for project management, and SERT is a third party and responsible for PV system study, conceptual design and all technical process. In this feasibility studies SERT will identify the most attractive scenarios of photovoltaic cell technology (mono, poly-crystalline or thin film amorphous), system design concepts for owners (TL) and determine possibility of the energy yield of the system from different module orientation and tilt angle. The result of this study is a guide to help TL to make decision to select proper rooftop PV system option for this store with proper technology view. The economic view will not be considered in this study. (orig.)

  3. Dutch Building Decree

    NARCIS (Netherlands)

    Scholten, N.P.M.

    2000-01-01

    On the 1 October 1992 a change in the Dutch building legislation took effect: the revised Housing Act, the Building Decree and the technical documents related to this legislation came into force. This publication contains an English translation of the Building Decree. In order to give an idea of the

  4. The business and technical case for Continuous Commissioning(reg Trade Mark) for enhanced building operations. A case study: Alamo Community College District San Antonio, Texas, U.S.A

    Energy Technology Data Exchange (ETDEWEB)

    Verdict, Malcolm; Wei, Guanghua [Texas A and M Univ. System, College Station, TX (United States). Energy Systems Laboratory

    2005-07-01

    This paper provides both the business and technical cases for the 'Continuous Commissioning' of large [>25,000 square feet], buildings through a whole building diagnostic and HVAC optimization approach known as 'Continuous Commissioning'. 'Continuous Commissioning' is defined as the ongoing engineering process to resolve operating problems, improve comfort, optimize energy use and identify retrofits in existing buildings and central plant facilities. It is also known as 'building retro-commissioning' or 'building tune-up'. It involves a rigorous, whole-building, engineering evaluation of the heating and cooling systems to identify mechanical problems, inadequate or ineffective control strategies. Some of the most common problems are: 1) Improper calibration of sensors and metering, 2) inadequate control strategies for optimum operation and comfort, 3) incorrect scheduling of heating and cooling equipment, 4) lack of air and water-side economizer equipment, 5) inadequate building automation systems, and 6) inadequate operations and maintenance. The CC process, described in this paper, was successfully applied at Alamo Community College District (ACCD) in San Antonio, Texas, USA by the Energy Systems Laboratory (ESL), a part of the Texas A and M Univ. System. ACCD has multiple buildings on 4 campuses with total conditioned area of 2.35 Million square feet. ACCD's business approach was unique because the cost of conducting the CC process was financed as an Energy Cost Reduction Measure (ECRM) along with several energy efficiency retrofits.

  5. Technical issues associated with in situ vitrification of the INEL Subsurface Disposal Area

    International Nuclear Information System (INIS)

    Stoots, C.M.; Bates, S.O.; Callow, R.A.; Campbell, K.A.; Farnsworth, R.K.; Gratson, G.K.; McKellar, M.G.; Nickelson, D.F.; Slater, C.E.

    1992-01-01

    In situ vitrification (ISV) has been identified as an alternative technology for remediation of the Acid Pit and Transuranic Pits and Trenches (TRU-PTs) that are present at the Idaho National Engineering Laboratory (INEL) Subsurface Disposal Area (SDA). However, a number of technical issues exist that must be resolved before ISV can be considered applicable to these waste sites. To assist in the ISV technology evaluation, an ISV Steering Committee was formed to identify, prioritize, and develop closure roadmaps for technical issues associated with ISV application at the INEL SDA. The activities of the ISV Steering Committee are summarized in three volumes of this report. Volume 1 identifies the systematic approach used to identify and prioritize the ISV technical issues, and briefly discusses the methodology that will be employed to resolve these issues. This document Volume 2 and Volume 3 discusses each technical issue in greater detail and suggest specific closure roadmaps to be used in resolving technical issues associated with ISV at the SDA Acid Pit and TRU-PTs, respectively

  6. Potential building sand deposits in Songkhla province area

    Directory of Open Access Journals (Sweden)

    Kooptarnond, K.

    2002-10-01

    Full Text Available An investigation of potential building sand deposits in Songkhla province area subdivided them into four regions according to their accumulation in various alluvial plains, meanders throughout alluvial deposits and residual soils. Four selected deposits, were Rattaphum-Khuan Niang, U-Taphao river, Na Mom, and Chana-Thepha regions. Information obtained from these deposits revealed a good correlation between the geomorphological features as interpreted from aerial photographs and those identified from vertical electrical resistivity sounding results. Sand samples were analysed for their physical and chemical properties. Petrographic studies were also undertaken to characterize the composition types, texture and shapes. An overview of the sand properties was used them to be within the acceptable limits for building sand. However, relatively high organic impurities and soundness were found in sand from Khuan Niang and Na Mom deposits. The result indicated a potential reconnaissance mineral resource of about 46 square kilometres.A reserve evaluation for natural building sand was carried out by using Geographic Information System (GIS. Maps of the various parameters considered were constructed in digital database format with the aid of Arc/Info and ArcView software. Overlay mapping and buffer zone modules were performed to evaluate inferred resources of building sand. The key parameters of analysis included the distance from transportation, distance from streams, lithology and thickness of sand layers. The remaining inferred sand total was of about 386 million cubic metres or about 1,021 million metric tons was therefore estimated, of which 60 percent lies in the Rattaphum-Khuan Niang region and 40 percent in the other regions.

  7. 47 CFR 22.383 - In-building radiation systems.

    Science.gov (United States)

    2010-10-01

    ... MOBILE SERVICES Operational and Technical Requirements Technical Requirements § 22.383 In-building radiation systems. Licensees may install and operate in-building radiation systems without applying for... 47 Telecommunication 2 2010-10-01 2010-10-01 false In-building radiation systems. 22.383 Section...

  8. Measurement in Sustainable Building

    DEFF Research Database (Denmark)

    Hale, Lara

    2018-01-01

    Measurement is a necessary aspect of planning and constructing buildings. However, recent attempts to integrate the social dimension of sustainable building into building design and specifications demand measurement of non-technical qualities, such as well-being. The Active House Alliance, in lieu...... and continued provision of sustainable buildings to market demand....

  9. Alkali-Activated Mortars for Sustainable Building Solutions: Effect of Binder Composition on Technical Performance

    Directory of Open Access Journals (Sweden)

    Agnese Attanasio

    2018-02-01

    Full Text Available There is a growing interest in the construction sector in the use of sustainable binders as an alternative to ordinary Portland cement, the production of which is highly impacting on the environment, due to high carbon dioxide emissions and energy consumption. Alkali-activated binders, especially those resulting from low-cost industrial by-products, such as coal fly ash or metallurgical slag, represent a sustainable option for cement replacement, though their use is more challenging, due to some technological issues related to workability or curing conditions. This paper presents sustainable alkali-activated mortars cured in room conditions and based on metakaolin, fly ash, and furnace slag (both by-products resulting from local sources and relevant blends, aiming at their real scale application in the building sector. The effect of binder composition—gradually adjusted taking into consideration technical and environmental aspects (use of industrial by-products in place of natural materials in the view of resources saving—on the performance (workability, compressive strength of different mortar formulations, is discussed in detail. Some guidelines for the design of cement-free binders are given, taking into consideration the effect of each investigated alumino-silicate component. The technical feasibility to produce the mortars with standard procedures and equipment, the curing in room conditions, the promising results achieved in terms of workability and mechanical performance (from 20.0 MPa up to 52.0 MPa, confirm the potential of such materials for practical applications (masonry mortars of class M20 and Md. The cement-free binders resulting from this study can be used as reference for the development of mortars and concrete formulations for sustainable building materials production.

  10. Humidity and Buildings. Technical Paper No. 188.

    Science.gov (United States)

    Hutcheon, N. B.

    Modified and controlled relative humidity in buildings for certain occupancies is discussed. New criteria are used in determining the needs, desirability and problems associated with humidities in a building. Severe winter climate requires that special attention be given to the problems associated with increased indoor humidities during cold…

  11. Build, renovate and invest economically - Efficiency and economic viability in harmony

    International Nuclear Information System (INIS)

    Meier, R.; Beck, M.; Previdoli, P.

    2002-01-01

    This book presents 13 papers that provide the latest know-how on energy economics in the building area. The authors show the importance of information and knowledge transfer when using new energy technologies. The topics covered include the role of the Swiss research programme on energy economy fundamentals, indicator systems for sustainability factors and energy characteristics of buildings. Also a discussion of the question 'rebuild or renovate', as well a series of articles about low-flow mechanical ventilation and the marketing of low-energy consumption building concepts are presented. Further articles cover the marketing of thermal solar systems as well as technology dissemination and monitoring. Also, the marginal costs of energy efficiency measures and the potential for energy savings and environmental management in trade and industry are discussed. Finally, two papers deal with the application of Swiss SIA building standards as well as technical developments and energy efficiency in the building and renovation areas

  12. Plutonium Equivalent Inventory for Belowground Radioactive Waste at the Los Alamos National Laboratory Technical Area 54, Area G Disposal Facility - Fiscal Year 2011

    International Nuclear Information System (INIS)

    French, Sean B.; Shuman, Robert

    2012-01-01

    The Los Alamos National Laboratory (LANL) generates radioactive waste as a result of various activities. Many aspects of the management of this waste are conducted at Technical Area 54 (TA-54); Area G plays a key role in these management activities as the Laboratory's only disposal facility for low-level radioactive waste (LLW). Furthermore, Area G serves as a staging area for transuranic (TRU) waste that will be shipped to the Waste Isolation Pilot Plant for disposal. A portion of this TRU waste is retrievably stored in pits, trenches, and shafts. The radioactive waste disposed of or stored at Area G poses potential short- and long-term risks to workers at the disposal facility and to members of the public. These risks are directly proportional to the radionuclide inventories in the waste. The Area G performance assessment and composite analysis (LANL, 2008a) project long-term risks to members of the public; short-term risks to workers and members of the public, such as those posed by accidents, are addressed by the Area G Documented Safety Analysis (LANL, 2011a). The Documented Safety Analysis uses an inventory expressed in terms of plutonium-equivalent curies, referred to as the PE-Ci inventory, to estimate these risks. The Technical Safety Requirements for Technical Area 54, Area G (LANL, 2011b) establishes a belowground radioactive material limit that ensures the cumulative projected inventory authorized for the Area G site is not exceeded. The total belowground radioactive waste inventory limit established for Area G is 110,000 PE-Ci. The PE-Ci inventory is updated annually; this report presents the inventory prepared for 2011. The approach used to estimate the inventory is described in Section 2. The results of the analysis are presented in Section 3.

  13. Building states without building nations: understanding urban citizenship in Dili, Timor Leste

    Directory of Open Access Journals (Sweden)

    Valenti, Alex

    2014-03-01

    Full Text Available State and nation building, although often used interchangeably in international relations policy and literature, are in fact two distinct, although closely intertwined, processes: the (recons-truction of a state cannot be reduced to a technical exercise, that is, state building; rather, it needs to focus just as significantly on the (reconstruction of the country’s social fabric in order to develop the sense of citizenship upon which its sovereignty and legitimacy rest, that is, nation building. This research note introduces urban spaces as interesting contexts to explore the relationship between state and nation building, arguing that their diversity is both a challenge and an opportunity for the state to create a sense of citizenship amongst its population. The case of Dili, the capital of Timor Leste, where a violent past and rapid urbanisation have combined to shape extremely diverse social, political and economic urban spaces, is used here to explore how the population of three case study areas perceives the impact of state policies and to question how these perceptions influence the scales at which people build their identity as well as how these scales affect the construction of local, urban or national citizenship in Timor Leste.

  14. Technical area status report for chemical/physical treatment

    International Nuclear Information System (INIS)

    Brown, C.H. Jr.; Schwinkendorf, W.E.

    1993-08-01

    The Office of Environmental Restoration and Waste Management (EM) was established by the Department of Energy (DOE) to direct and coordinate waste management and site remediation programs and activities throughout the DOE Complex. The Mixed Waste Integrated Program (MWIP) was created by the DOE Office of Technology Development (OTD) to develop, deploy, and complete appropriate technologies for the treatment of an DOE low-level mixed waste (LLMW). The MWIP mission includes development of strategies related to enhanced waste form production, improvements to and testing of the EM-30 baseline flowsheet for mixed waste treatment, programmatic oversight for ongoing technical projects, and specific technical tasks related to the site specific Federal Facilities Compliance Agreement (FFCA). The MWIP has established five Technical Support Groups (TSGs) based on primary functional areas of the Mixed Waste Treatment Plant) identified by EM-30. These TSGs are: (1) Front-End Waste Handling, (2) Chemical/Physical Treatment, (3) Waste Destruction and Stabilization, (4) Second-stage Destruction and Offgas Treatment, and (5) Final Waste Forms. The focus of this document is the Chemical/Physical Treatment System (CPTS). The CPTS performs the required pretreatment and/or separations on the waste streams passing through the system for discharge to the environment or efficient downstream processing. Downstream processing can include all system components except Front-End Waste Handling. The primary separations to be considered by the CPTS are: (1) removal of suspended and dissolved solids from aqueous and liquid organic streams, (2) separation of water from organic liquids, (3) treatment of wet and dry solids, including separation into constituents as required, for subsequent thermal treatment and final form processing, (4) mercury removal and control, and (5) decontamination of equipment and waste classified as debris

  15. Research on Building Urban Sustainability along the Coastal Area in China

    OpenAIRE

    Sun Jiaojiao; Fu Jiayan

    2015-01-01

    At present, in China, the research about the urban sustainability construction is still in the exploratory stage. The ecological problems of the coastal area are more sensitive and complicated. In the background of global warming with serious ecological damage, this paper deeply researches on the main characteristics of urban sustainability and measures how to build urban sustainability. Through combining regional environmental with economic ability along the coastal area...

  16. Technical basis for removal of 221-T tunnel from airborne radiological area status

    International Nuclear Information System (INIS)

    Geuther, W.J.

    1996-01-01

    This document provides the technical basis for removal of the 221-T Tunnel from airborne radiological control. T Plant Radiological Control has evaluated air sampling data and engineering controls, and determined the necessary administrative controls to make this transition. With these administrative controls (specified within document) in place, the tunnel can be removed from Airborne Radioactive Area status. The removal of the tunnel from airborne status will allow work to be performed within the tunnel under controlled conditions, as outlined in this technical basis, without the use of respiratory protection equipment

  17. Building America Industrialized Housing Partnership (BAIHP II)

    Energy Technology Data Exchange (ETDEWEB)

    Abernethy, Bob; Chandra, Subrato; Baden, Steven; Cummings, Jim; Cummings, Jamie; Beal, David; Chasar, David; Colon, Carlos; Dutton, Wanda; Fairey, Philip; Fonorow, Ken; Gil, Camilo; Gordon, Andrew; Hoak, David; Kerr, Ryan; Peeks, Brady; Kosar, Douglas; Hewes, Tom; Kalaghchy, Safvat; Lubliner, Mike; Martin, Eric; McIlvaine, Janet; Moyer, Neil; Liguori, Sabrina; Parker, Danny; Sherwin, John; Stroer, Dennis; Thomas-Rees, Stephanie; Daniel, Danielle; McIlvaine, Janet

    2010-11-30

    This report summarizes the work conducted by the Building America Industrialized Housing Partnership (BAIHP - www.baihp.org) during the final budget period (BP5) of our contract, January 1, 2010 to November 30, 2010. Highlights from the four previous budget periods are included for context. BAIHP is led by the Florida Solar Energy Center (FSEC) of the University of Central Florida. With over 50 Industry Partners including factory and site builders, work in BP5 was performed in six tasks areas: Building America System Research Management, Documentation and Technical Support; System Performance Evaluations; Prototype House Evaluations; Initial Community Scale Evaluations; Project Closeout, Final Review of BA Communities; and Other Research Activities.

  18. Technical issues associated with in situ vitrification of the INEL Subsurface Disposal Area

    International Nuclear Information System (INIS)

    Stoots, C.M.; Bates, S.O.; Callow, R.A.; Campbell, K.A.; Farnsworth, R.K.; Krisman, G.K.; McKellar, M.G.; Nickelson, D.F.; Slater, C.E.

    1992-07-01

    In situ vitrification (ISV) has been identified as an alternative technology for remediation of the acid pit and transuranic pits and trenches (TRU-PTs) at the Idaho National Engineering Laboratory (INEL) Subsurface Disposal Area (SDA). However, a number of technical issues must be resolved before ISV can be considered applicable to these waste sites. To assist in the ISV technology evaluation, an ISV Steering Committee was formed to identify, prioritize, and develop closure roadmaps for technical issues lated with ISV application at the SDA. The activities of the ISV Steering Committee are summarized in a three-volume report. Volume I identifies the systematic approach used to identify and prioritize the ISV technical issues and briefly discusses the methodology that will be employed to resolve these issues. Volumes 2 and 3 discuss each technical issue in greater detail and suggest specific closure roadmaps to be used in resolving technical issues associated with ISV at the SDA Acid Pit and TRU-PTS, respectively. The three-volume report is a working document that will be updated as necessary to reflect current evaluation strategy for the ISV technology. This is Volume 3

  19. Windows and Building Envelope Research and Development: A Roadmap for Emerging Technologies

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-02-01

    This Building Technologies Office (BTO) Research and Development (R&D) Roadmap identifies priority windows and building envelope R&D areas of interest. Cost and performance targets are identified for each key R&D area. The roadmap describes the technical and market challenges to be overcome, R&D activities and milestones, key stakeholders, and potential energy savings that could result if cost and performance targets are met. Methods for improving technology performance and specific strategies for reducing installed costs and mitigating any other market barriers, which would increase the likelihood of mass-market technology adoption, are identified. This roadmap is a useful resource for public and private decision makers evaluating and pursuing high-impact R&D focused on advancing next-generation energy efficient windows and building envelope technologies.

  20. Technical issues associated with in situ vitrification of the INEL Subsurface Disposal Area

    International Nuclear Information System (INIS)

    Stoots, C.M.; Bates, S.O.; Callow, R.A.; Campbell, K.A.; Farnsworth, R.K.; Gratson, G.K.; McKellar, M.G.; Nickelson, D.F.; Slater, C.E.

    1991-12-01

    In situ vitrification (ISV) has been identified as an alternative technology for remediation of the Acid Pit and Transuranic Pits and Trenches (TRU-PTs) that are present at the Idaho National Engineering Laboratory (INEL) Subsurface Disposal Area (SDA). However, a number of technical issues exist that must be resolved before ISV can be considered applicable to these waste sites. To assist in the ISV technology evaluation, an ISV Steering Committee was formed to identify, prioritize, and develop closure roadmaps for technical issues associated with ISV application at the INEL SDA. The activities of the ISV Steering Committee are summarized in three volumes of this report. This document, Volume 1, identifies the systematic approach used to identify and prioritize the ISV technical issues, and briefly discusses the methodology that will be employed to resolve these issues

  1. The simulated measurements of area and personal neutron-gamma dose equivalent in the building of HWRR

    International Nuclear Information System (INIS)

    Chen Changmao; Wen Youqin; Su Jingling; Liu Shuying; Liu Nairong

    1988-01-01

    The measuring methods and results for area and personal n-γ dose equivalent in the building of HWRR of Institute of Atomic Energy were reported. The reactor operated 4440 hours during 1985, the average themal power was 11 MW. The average area n-γ dose equivalents of the basement, experimental hall, corridors and laboratories in the building were 12.2, 11.6, 0.45 and 0.23 cSv/a, respectively. The fraction of the neutron dose equivalent in any working area was less than 21%. The average personal n-γ dose equivalent to radiation workers in the building was about 0.49 cSv/a, the γ dose equivalent was a major component. The measuring methods were compared

  2. Material and energy balances of technical means in horticulture and farming - from production to disposal

    International Nuclear Information System (INIS)

    1993-01-01

    The twenty papers of this progress report, which are not individually recorded, belong to either one of the subject areas ''material and energy balances of technical means in horticulture and forming from production to disposal'' and ''plastics in construction and technical systems''. The first-mentioned subject area deals with balances for technical means at horticultural enterprises, greenhouse constructions, and styrofoam in farm buildings, and comprises short papers on sewage treatment plants in the form of beds of plants and ecological aspects of horticultural activities in open spaces. The second subject area mainly concerns recycling and multiple uses of plastics (silage and protective foils) as well as air-flow thermal collector systems. Advances in the construction and use of foil-covered greenhouses and experience with protective nets for plant cultures, energy shields, and shading are reported. (UWA) [de

  3. National Ignition Facility subsystem design requirements laser and target area building (LTAB) SSDR 1.2.2.1

    International Nuclear Information System (INIS)

    Kempel, P.; Hands, J.

    1996-01-01

    This Subsystem Design Requirements (SSDR) document establishes the performance, design, and verification requirements for the conventional building systems and subsystems of the Laser and Target Area Building (LTAB), including those that house and support the operation of high-energy laser equipment and the operational flow of personnel and materials throughout the facility. This SSDR addresses the following subsystems associated with the LTAB: Building structural systems for the Target Bay, Switchyards, Diagnostic Building, Decontamination Area, Laser Bays, Capacitor Bays and Operations Support Area, and the necessary space associated with building-support equipment; Architectural building features associated with housing the space and with the operational cleanliness of the functional operation of the facilities; Heating, Ventilating, and Air Conditioning (HVAC) systems for maintaining a clean and thermally stable ambient environment within the facilities; Plumbing systems that provide potable water and sanitary facilities for the occupants, plus stormwater drainage for transporting rainwater; Fire Protection systems that guard against fire damage to the facilities and their contents; Material handling systems for transporting personnel and heavy materials within the building areas; Mechanical process piping systems for liquids and gases that provide cooling and other service to experimental laser equipment and components; Electrical power and grounding systems that provide service and standby power to building and experimental equipment, including lighting distribution and communications systems for the facilities; Instrumentation and control systems that ensure the safe operation of conventional facilities systems, such as those listed above. Detailed requirements for building subsystems that are not addressed in this document (such as specific sizes, locations, or capacities) are included in detail-level NIP Project Interface Control Documents (ICDS)

  4. Kyiv institutional buildings sector energy efficiency program: Technical assessment

    Energy Technology Data Exchange (ETDEWEB)

    Secrest, T.J.; Freeman, S.L. [Pacific Northwest National Lab., Richland, WA (United States); Popelka, A. [Tysak Engineering, Acton, MA (United States); Shestopal, P.A.; Gagurin, E.V. [Agency for Rational Energy Use and Ecology, Kyiv (Ukraine)

    1997-08-01

    The purpose of this assessment is to characterize the economic energy efficiency potential and investment requirements for space heating and hot water provided by district heat in the stock of state and municipal institutional buildings in the city of Kyiv. The assessment involves three activities. The first is a survey of state and municipal institutions to characterize the stock of institutional buildings. The second is to develop an estimate of the cost-effective efficiency potential. The third is to estimate the investment requirements to acquire the efficiency resource. Institutional buildings are defined as nonresidential buildings owned and occupied by state and municipal organizations. General categories of institutional buildings are education, healthcare, and cultural. The characterization activity provides information about the number of buildings, building floorspace, and consumption of space heating and hot water energy provided by the district system.

  5. Analysis of heat source selection for residential buildings in rural areas

    Directory of Open Access Journals (Sweden)

    Szul Tomasz

    2018-01-01

    Full Text Available The research aiming to check whether the output of currently installed boilers matches the use requirements together with estimation of their energy efficiency was carried out on a group of 84 single-family residential buildings located in rural areas. Heating and hot water energy needs were calculated for each building in order to determine the use requirements. This enabled verification whether the currently installed boilers match the actual use requirements in the buildings. Based on the calculations it was determined that the designed average boiler output in the group of buildings subject to analysis is 15.7 kW, whereas the mean rated output capacity of boilers installed therein is 25.4 kW. On average, the output capacity of the installed boilers exceeds the use requirements for the buildings by 60%. To calculate the energy efficiency of boilers, the mean annual boiler output capacity use coefficient was determined. For boilers selected on the basis of standard calculations, the mean coefficient is 0.47. For boilers currently in use it is 0.31, less than the above figure. The above calculations show that if boilers were correctly selected in compliance to the building needs, then the average estimated seasonal efficiency of 65% would be feasible. However, in the current state the achievable efficiency is approx. 55%.

  6. Tribal Green Building Administrative Code Example

    Science.gov (United States)

    This Tribal Green Building Administrative Code Example can be used as a template for technical code selection (i.e., building, electrical, plumbing, etc.) to be adopted as a comprehensive building code.

  7. Economical, environmental and technical analysis of building integrated photovoltaic systems in Malaysia

    Energy Technology Data Exchange (ETDEWEB)

    Seng, Lim Yun [Department of Physical Science, Electrical and Electronic Engineering, Tunku Abdul Rahman University, 53300 Setapak, Kuala Lumpur (Malaysia); Lalchand, G.; Sow Lin, Gladys Mak [Malaysia Energy Centre, Building Integrated Photovoltaic Project (Malaysia)

    2008-06-15

    Malaysia has identified photovoltaic systems as one of the most promising renewable sources. A great deal of efforts has been undertaken to promote the wide applications of PV systems. With the recent launch of a PV market induction programme known as SURIA 1000 in conjunction with other relevant activities undertaken under the national project of Malaysia Building Integrated Photovoltaic (MBIPV), the market of PV systems begins to be stimulated in the country. As a result, a wide range of technical, environmental and economic issues with regard to the connection of PV systems to local distribution networks becomes apparent. Numerous studies were therefore carried out in collaboration with Malaysian Energy Centre to address a number of those important issues. The findings of the studies are presented in the paper and can be served as supplementary information to parties who are directly and indirectly involved in the PV sector in Malaysia. (author)

  8. Economical, environmental and technical analysis of building integrated photovoltaic systems in Malaysia

    International Nuclear Information System (INIS)

    Seng, Lim Yun; Lalchand, G.; Sow Lin, Gladys Mak

    2008-01-01

    Malaysia has identified photovoltaic systems as one of the most promising renewable sources. A great deal of efforts has been undertaken to promote the wide applications of PV systems. With the recent launch of a PV market induction programme known as SURIA 1000 in conjunction with other relevant activities undertaken under the national project of Malaysia Building Integrated Photovoltaic (MBIPV), the market of PV systems begins to be stimulated in the country. As a result, a wide range of technical, environmental and economic issues with regard to the connection of PV systems to local distribution networks becomes apparent. Numerous studies were therefore carried out in collaboration with Malaysian Energy Centre to address a number of those important issues. The findings of the studies are presented in the paper and can be served as supplementary information to parties who are directly and indirectly involved in the PV sector in Malaysia. (author)

  9. Access a better development for Chinese sustainable building -A study of problems and proposal from a technical view

    OpenAIRE

    Gong, Boyun

    2012-01-01

    Sustainable building issue plays a key role in world sustainable development as the building industry converge major sectors of energy, water and material consumption that have huge affect on social and environment. Modern China is under the process of sifting from agriculture society to industrialized society, experiencing a fast economic growth and urbanization, facing big amount of environment and energy problems. Large amount of migration swam from rural area to urban area, which bring up...

  10. Technical Problems of Residential Construction

    Science.gov (United States)

    Nowogońska, Beata; Cibis, Jerzy

    2017-10-01

    Beauty, utility, durability - these are the features of good architecture and should also be the distinguishing qualities of every residential building. But do beauty and utility remain along with the passing of time? Performance characteristics are an indicator of both, the technical as well as aesthetic state of buildings. Aesthetic needs are in disagreement with the merciless aging process. The beauty of a city is formed not only by the original forms of new residential buildings, but also by existing tenement housing; thus preserving their aesthetics becomes a necessity. Time is continuously passing and along with it, aging intensifies. The aging process is a natural phenomenon for every material. The life expectancy of building materials is also limited. Along with the passing of time, the technical state of residential buildings continuously deteriorates. With the passing of time, the aesthetic values and preferences of users of flats change and the usability of the building decreases. The permanence of buildings, including residential buildings, is shaped not only by the forces of nature but also by activities of humans. A long lifespan is ensured by carrying out ongoing, systematic renovation-repair works. It is thanks to them that buildings derived from past centuries are still being used, and their market attractiveness is not decreasing.

  11. Integration of Photovoltaics in Buildings—Support Policies Addressing Technical and Formal Aspects

    Directory of Open Access Journals (Sweden)

    Thorsten Schuetze

    2013-06-01

    Full Text Available The integration of photovoltaic (PV generators in the envelope of a building by means of building-integrated photovoltaics (BIPV offers an immense potential, both in market development and the production of renewable electric energy that is close to the point of electricity consumption. In Germany, for example, by integrating photovoltaics in buildings up to 50% of the electricity demand can be covered. The political support of BIPV would contribute to the development and installation of BIPV components and therefore also promote the development of new business areas for industries dealing with components used in building envelopes and photovoltaic generators. BIPV can be separated into three different integration types: “technical”, “formal” and “technical & formal”. Political instruments for the support of PV-installations, particularly BIPV are discussed in this paper using Germany and France as examples. Due to successful financial support policies, PV became the most powerful electricity production technology in Germany. In France, the unique financial support of BIPV is resulting in an exemplary development and growth of certified BIPV components available on the market and, from a technical, aesthetic architectural and legal certainty point of view, facilitating the easy and widespread integration of photovoltaic generators in buildings.

  12. Problems of Technology of Energy-Saving Buildings and Their Impact on Energy Efficiency in Buildings

    Science.gov (United States)

    Kwasnowski, Pawel; Fedorczak-Cisak, Malgorzata; Knap, Katarzyna

    2017-10-01

    Introduction of EPBD in legislation of the EU member states caused that buildings must meet very stringent requirements of thermal protection and energy efficiency. On the basis of EPBD provisions, EU Member States introduce standard of NZEB (Nearly Zero-Energy Buildings). Such activities cause a need for new, innovative materials and technologies, and new approaches to design, construction and retrofitting of buildings. Indispensable is the precise coordination of the design of structure and technical installations of building, which may be provided in an integrated design process in the system BIM. Good coordination and cooperation of all contractors during the construction phase is also necessary. The article presents the problems and the new methodology for the design, construction and use of energy efficient buildings in terms of energy saving technologies, including discussion of the significant impact of the automation of technical installations on the building energy efficiency.

  13. Integrated engineering system for nuclear facilities building

    International Nuclear Information System (INIS)

    Tomura, H.; Miyamoto, A.; Futami, F.; Yasuda, S.; Ohtomo, T.

    1995-01-01

    In the construction of buildings for nuclear facilities in Japan, construction companies are generally in charge of the building engineering work, coordinating with plant engineering. An integrated system for buildings (PROMOTE: PROductive MOdeling system for Total nuclear Engineering) described here is a building engineering system including the entire life cycle of buildings for nuclear facilities. A Three-dimensional (3D) building model (PRO-model) is to be in the core of the system (PROMOTE). Data sharing in the PROMOTE is also done with plant engineering systems. By providing these basic technical foundations, PROMOTE is oriented toward offering rational, highquality engineering for the projects. The aim of the system is to provide a technical foundation in building engineering. This paper discusses the characteristics of buildings for nuclear facilities and the outline of the PROMOTE. (author)

  14. Energy and Environmental Research in the Building Area; Forschen und Bauen im Kontext von Energie und Umwelt

    Energy Technology Data Exchange (ETDEWEB)

    Binz, A. [Fachhochschule Nordwestschweiz (HABG-IEB), Muttenz (Switzerland); Chianese, D. [Scuola Universitaria Professionale della Svizzera Italiana, Dipartimento Ambiente Costruzioni e Design, Instituto di Sostenibilita Applicata all' Ambiente Costruito (SUPSI-DACD-ISAAC), Canobbio (Switzerland); Filleux, Ch. [Basler und Hofmann, Zuerich (Switzerland); Gaegauf, Ch. [Oekozentrum Langenbruck, Langenbruck (Switzerland); Gugerli, H. [Amt fuer Hochbauten der Stadt Zuerich, Zuerich (Switzerland); Menti, U.-P. [Hochschule Luzern, Technik und Architektur, Horw (Switzerland); Rommel, M. [Hochschule fuer Technik, Institut fuer Solartechnik (SPF), Rapperswil (Switzerland); Schwehr, P. [brenet, building and renewable energies network of technology, HTA Luzern, Horw (Switzerland); Zimmermann, M. [Swiss Federal Laboratories for Materials Testing and Research (EMPA), Duebendorf (Switzerland)

    2010-07-01

    These proceedings of the 16{sup th} Swiss Status Seminar held in September 2010 at the Swiss Federal Institute of Technology ETH in Zurich, Switzerland, present a comprehensive overview of the two-day event on Swiss energy and environmental topics in the building area. A total of 55 lectures in ten sessions covered architectural and building topics. The main lectures at the beginning of the seminar covered models for sustainable city development, building for the 2000-watt society and design principles. Also the 'Tropical House' project, the 'Self' autonomous house, the new Monte Rosa mountaineers hut and the Swiss Village project in Masdar were presented. The presentations were divided into nine thematic areas: The house as a 'power station', building renewal, energy management, heat pumps, processes, innovative building and renovation, city districts, building technologies, ventilation and the building as a system. Twenty poster contributions completed the seminar. Themes addressed in the 'house as a power station' set looked at the local generation of power, buildings that generate or even export energy and low-energy consumption buildings. Building renewal topics discussed included grey energy and legal topics, energy management contributions dealt with control, hot water preparation and energy efficiency. The heat pump section dealt with theory and practice of heating and cooling, multi-functional and low-exergy systems and related calculation aids. The processes section included contributions on infra-red analysis, solar-assisted systems, modelling, eco-balances and the City of Zurich's resource strategy for mineral building materials. Innovative building and renovation topics included renovation with prefabricated elements, integrated photovoltaic modules, retrofits as well as financing topics. The topics covered in the district development set included contributions on sustainable (re-)development, the 2000-watt

  15. Green Building Research Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Sailor, David Jean [Portland State Univ., Portland, OR (United States)

    2013-12-29

    This project provided support to the Green Building Research Laboratory at Portland State University (PSU) so it could work with researchers and industry to solve technical problems for the benefit of the green building industry. It also helped to facilitate the development of PSU’s undergraduate and graduate-level training in building science across the curriculum.

  16. Summary of Tiger Team Assessment and Technical Safety Appraisal recurring concerns in the Operations Area

    International Nuclear Information System (INIS)

    1993-01-01

    Fourteen Tiger Team Assessment and eight Technical Safety Appraisal (TSA) final reports have been received and reviewed by the DOE Training Coordination Program during Fiscal Year 1992. These assessments and appraisals included both reactor and non-reactor nuclear facilities in their reports. The Tiger Team Assessments and TSA reports both used TSA performance objectives, and list ''concerns'' as a result of their findings. However, the TSA reports categorized concerns into the following functional areas: (1) Organization and Administration, (2) Radiation Protection, (3) Nuclear Criticality Safety, (4) Occupational Safety, (5) Engineering/Technical Support, (6) Emergency Preparedness, (7) Safety Assessments, (8) Quality Verification, (9) Fire Protection, (10) Environmental Protection, and (11) Energetic Materials Safety. Although these functional areas match most of the TSA performance objectives, not all of the TSA performance objectives are addressed. For example, the TSA reports did not include Training, Maintenance, and Operations as functional areas. Rather, they included concerns that related to these topics throughout the 11 functional areas identified above. For consistency, the Operations concerns that were identified in each of the TSA report functional areas have been included in this summary with the corresponding TSA performance objective

  17. Contamination source review for Building E3236, Edgewood Area, Aberdeen Proving Ground, Maryland

    Energy Technology Data Exchange (ETDEWEB)

    Zellmer, S.D.; Smits, M.P.; Draugelis, A.K.; Glennon, M.A.; Rueda, J.; Zimmerman, R.E.

    1995-09-01

    The US Army Aberdeen Proving Ground (APG) commissioned Argonne National Laboratory (ANL) to conduct a contamination source review to identify and define areas of toxic or hazardous contaminants and to assess the physical condition and accessibility of APG buildings. The information obtained from the review may be used to assist the US Army in planning for the future use or disposition of the buildings. The contamination source review consisted of the following tasks: historical records search, physical inspection, photographic documentation, geophysical investigation, and review of available records regarding underground storage tanks associated with each building. This report provides the results of the contamination source review for Building E3236. Many of the APG facilities constructed between 1917 and the 1960s are no longer used because of obsolescence and their poor state of repair. Because many of these buildings were used for research, development, testing, and/or pilot- scale production of chemical warfare agents and other military substances, the potential exists for portions of the buildings to be contaminated with these substances, their degradation products, and other laboratory or industrial chemicals. These buildings and associated structures or appurtenances may contribute to environmental concerns at APG.

  18. Contamination source review for Building E2370, Edgewood Area, Aberdeen Proving Ground, Maryland

    Energy Technology Data Exchange (ETDEWEB)

    O`Reilly, D.P.; Glennon, M.A.; Draugelis, A.K.; Rueda, J.; Zimmerman, R.E.

    1995-09-01

    The US Army Aberdeen Proving Ground (APG) commissioned Argonne National Laboratory (ANL) to conduct a contamination source review to identify and define areas of toxic or hazardous contaminants and to assess the physical condition and accessibility of APG buildings. The information obtained from this review may be used to assist the US Army in planning for the future use or disposition of the buildings. The contamination source review consisted of the following tasks: historical records search, physical inspection, photographic documentation, and geophysical investigation. This report provides the results of the contamination source review for Building E2370. Many of the APG facilities constructed between 1917 and the 1960s are no longer used because of obsolescence and their poor state of repair. Because many of these buildings were used for research, development, testing, and/or pilot-scale production of chemical warfare agents and other military substances, the potential exists for portions of the buildings to be contaminated with these substances, their degradation products, and other laboratory or industrial chemicals. These buildings and associated structures or appurtenances may contribute to environmental concerns at APG.

  19. The building network energy statistics 2004[Norway]; Bygningsnettverkets energistatistikk 2004

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    The energy statistics for 2004 is the 8th in a row from the building network. The report presents analysis and statistics for various building energy use and technical installations. There are 1907 building objects included in the statistics situated in 254 of the counties in the country. In all this includes 9.3 mill. square meters heated area. Out of this 2.5 % residences is mainly constituted of department buildings. The rest is non-residential buildings in total 7.6 % of the entire building mass in Norway. The total energy consumption in the selection in 2004 is approx. 2.4 TWh. The climate in Norway in 2004 was the 6th warmest since the measurements started for 138 years ago. The report includes energy gradient figures and energy use from various climatic zones. The report shows the energy consumption distributed on various building types, variations in the energy consumption depending on the type of heating system, cooling, building sizes, ages and other factors. Figures for the energy consumption related to building function are included. Approx. 60 % of the buildings is new since the last yearly report. Those that were included in the 2003 report show a reduction in the temperature corrected specific energy consumption of 4.7 % from 2003 to 2004. The oil consumption has been reduced the most. Several building types have reduced the oil consumption with 50% and the total reduction is about 11 mill. litres of oil. The reasons are partly a switch to electric heating systems and partly a general reduction of the energy consumption. The report also includes statistics regarding technical conditions in the buildings such as heating system types, energy carriers, cooling, ventilation, energy flexibility, utilization and other factors. (tk)

  20. [Evaluation of residual osteomuscular function using computerised movement analysis for building sector workers: specificity and technical problem].

    Science.gov (United States)

    D'Orso, M I; Centemeri, R; Latocca, R; Riva, M; Cesana, G

    2012-01-01

    Occupational Health Doctors active in building sector firms frequently have to evaluate residual workers' osteomuscular function in patients coming back to work after an accident happened during work time or free time. Definition of their specific individual work suitability is usually carried out utilizing semeiotic tests in which subjective evaluation of every single Medical Doctor is real important in definition of final results and this fact can cause legal controversies. In our research we describe the application of computerised movement analysis on 10 workers of building sector. In every patient examined this technical method has been able to study objectively the tridimensional ranges of motion of most important osteomuscular districts. The possibility to have an objective evaluation of residual osteomuscular function has a relevant importance both in definition of workers' work suitability at the moment in which they start again their activities and in possible future legal conflicts.

  1. Mixed Waste Focus Area integrated technical baseline report, Phase 1: Volume 1

    International Nuclear Information System (INIS)

    1996-01-01

    The Department of Energy (DOE) established the Mixed Waste Characterization, Treatment, and Disposal Focus Area (MWFA) to develop and facilitate implementation of technologies required to meet the Department's commitments for treatment of mixed low-level and transuranic wastes. The mission of the MWFA is to provide acceptable treatment systems, developed in partnership with users and with participation of stakeholders, tribal governments, and regulators, that are capable of treating DOE's mixed waste. These treatment systems include all necessary steps such as characterization, pretreatment, and disposal. To accomplish this mission, a technical baseline is being established that forms the basis for determining which technology development activities will be supported by the MWFA. The technical baseline is the prioritized list of deficiencies, and the resulting technology development activities needed to overcome these deficiencies. This document presents Phase I of the technical baseline development process, which resulted in the prioritized list of deficiencies that the MWFA will address. A summary of the data and the assumptions upon which this work was based is included, as well as information concerning the DOE Office of Environmental Management (EM) mixed waste technology development needs. The next phase in the technical baseline development process, Phase II, will result in the identification of technology development activities that will be conducted through the MWFA to resolve the identified deficiencies

  2. Building America Industrialized Housing Partnership (BAIHP)

    Energy Technology Data Exchange (ETDEWEB)

    McIlvaine, Janet; Chandra, Subrato; Barkaszi, Stephen; Beal, David; Chasar, David; Colon, Carlos; Fonorow, Ken; Gordon, Andrew; Hoak, David; Hutchinson, Stephanie; Lubliner, Mike; Martin, Eric; McCluney, Ross; McGinley, Mark; McSorley, Mike; Moyer, Neil; Mullens, Mike; Parker, Danny; Sherwin, John; Vieira, Rob; Wichers, Susan

    2006-06-30

    This final report summarizes the work conducted by the Building America Industrialized Housing Partnership (www.baihp.org) for the period 9/1/99-6/30/06. BAIHP is led by the Florida Solar Energy Center of the University of Central Florida and focuses on factory built housing. In partnership with over 50 factory and site builders, work was performed in two main areas--research and technical assistance. In the research area--through site visits in over 75 problem homes, we discovered the prime causes of moisture problems in some manufactured homes and our industry partners adopted our solutions to nearly eliminate this vexing problem. Through testing conducted in over two dozen housing factories of six factory builders we documented the value of leak free duct design and construction which was embraced by our industry partners and implemented in all the thousands of homes they built. Through laboratory test facilities and measurements in real homes we documented the merits of 'cool roof' technologies and developed an innovative night sky radiative cooling concept currently being tested. We patented an energy efficient condenser fan design, documented energy efficient home retrofit strategies after hurricane damage, developed improved specifications for federal procurement for future temporary housing, compared the Building America benchmark to HERS Index and IECC 2006, developed a toolkit for improving the accuracy and speed of benchmark calculations, monitored the field performance of over a dozen prototype homes and initiated research on the effectiveness of occupancy feedback in reducing household energy use. In the technical assistance area we provided systems engineering analysis, conducted training, testing and commissioning that have resulted in over 128,000 factory built and over 5,000 site built homes which are saving their owners over $17,000,000 annually in energy bills. These include homes built by Palm Harbor Homes, Fleetwood, Southern Energy

  3. Technical Training: Technical Training Seminar

    CERN Multimedia

    2004-01-01

    Tuesday 30 March TECHNICAL TRAINING SEMINAR From 9:00 to 12:00 and from 13:00 to 16:00 hrs - Council Chamber, Salle B, Salle des Pas Perdus National Instruments (NI) on Tour 2004 Claudia Jüngel, Evrem Yarkin, Joel Clerc, Hervé Baour / NATIONAL INSTRUMENTS The special event NI on Tour 2004, run in Germany, Austria and Switzerland, will be at CERN on March 30. Technical seminars and free introductory courses will be offered all day long in the Council Chamber, Salle B, and Salle des Pas Perdus (buildings 61 and 503). Technical conferences: 09:00 - 12:00 Data acquisition systems on PCs. Industrial measurement and control techniques. 13:00 - 16:00 Advanced LabVIEW software and PXI instrumentation. Measuring instruments and system components for teststand automation. Introductory courses: 09:00 - 12:00 DIAdem: Data analysis and presentation 13:00 - 16:00 Data acquisition with LabVIEW Language: English and French Free special seminar. Registration is recommended with National Instruments Switzerland (please sp...

  4. Technical Training: Technical Training Seminar

    CERN Multimedia

    2004-01-01

    Tuesday 30 March TECHNICAL TRAINING SEMINAR From 9:00 to 12:00 and from 13:00 to 16:00 hrs - Council Chamber, Salle B, Salle des Pas Perdus National Instruments (NI) on Tour 2004 Claudia Jüngel, Evrem Yarkin, Joel Clerc, Hervé Baour / NATIONAL INSTRUMENTS The special event NI on Tour 2004, run in Germany, Austria and Switzerland, will be at CERN on March 30. Technical seminars and free introductory courses will be offered all day long in the Council Chamber, Salle B, and Salle des Pas Perdus (buildings 61 and 503). Technical conferences: 09:00 - 12:00 Data acquisition systems on PCs. Industrial measurement and control techniques. 13:00 - 16:00 Advanced LabVIEW software and PXI instrumentation. Measuring instruments and system components for teststand automation. Introductory courses: 09:00 - 12:00 DIAdem: Data analysis and presentation 13:00 - 16:00 Data acquisition with LabVIEW Language: English and French Free special seminar. Registration is recommended with National Instruments Swi...

  5. Technical Potential Assessment for the Renewable Energy Zone (REZ) Process: A GIS-Based Approach

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nathan [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Roberts, Billy J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-04-05

    Geographic Information Systems (GIS)-based energy resource and technical potential assessments identify areas capable of supporting high levels of renewable energy (RE) development as part of a Renewable Energy Zone (REZ) Transmission Planning process. This document expands on the REZ Process to aid practitioners in conducting GIS-based RE resource and technical potential assessments. The REZ process is an approach to plan, approve, and build transmission infrastructure that connects REZs - geographic areas that have high-quality RE resources, suitable topography and land-use designations, and demonstrated developer interest - to the power system. The REZ process helps to increase the share of solar photovoltaic (PV), wind, and other resources while also maintaining reliability and economics.

  6. Technical specifications of variable speed motors for negative pressure control in hot cell area

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seon Duk; Bang, H. S.; Cho, W. K

    2002-01-01

    Hot cells are the facilities for handling the high radioactive materials and various R and D activities are performed using hot cells. Therefore the control of air flow in hot cell area is very important technology and it is started with the variable speed motor(VSM) controlling the air handling system in that area. This report describes various technical aspects of VS motors and will be useful for understanding the practical technologies of VS motors and also for optimization of the negative pressure controls in hot cell area.

  7. Energy consumption in buildings within the services sector. 2008; Energibruk i bygninger for tjenesteytende virksomhet. 2008

    Energy Technology Data Exchange (ETDEWEB)

    Abrahamsen, Anne Sofie; Bergh, Marius

    2011-05-15

    The population and sample for this survey are based on data from The Ground Parcel, Address and Building Register (GAB) as of 1 January 2008. GAB is a computer register containing information about ground properties and addresses in Norway. Defined by type of building, around 130 000 buildings within the services sector are included in the register. Buildings with an unspecified owner, buildings smaller than 200 m2 and some special types of buildings (garages etc.) were excluded from the population, thus giving a total of just over 60 000 buildings. The gross sample was made up of 8 100 buildings, and questionnaires were sent to the landowners of these buildings. In addition to the Statistics Norway sample, data from Enova and Statsbygg, among others, was used. The net sample included about 5 000 buildings. The relatively low number of usable questionnaires in the Statistics Norway sample was related to both the quality of the data in GAB and in the reported data. The use of energy per square metre between the different types of buildings in the survey varies considerably. This is due to several factors, such as time of use of the buildings, the amount of technical equipment in the buildings, energy efficiency etc. The average for all the buildings in the survey for 2008 was 226 kWh/m2. Total energy consumption in the survey was slightly more than 5 TWh distributed over 22.5 million m2 of heated area. Electric power accounted for 83 per cent of the energy used and was by far the largest energy carrier. District heating was the second largest energy carrier with 11 per cent, while heating oil accounted for about 3 per cent. Wood and pellets made up slightly less than 2 per cent and other energy carriers totalled 0.4 per cent. Schools and kindergartens had by far the lowest use of energy, with an average of 159 kWh/m2. This is related to the relatively low time of use of the buildings and fewer technical installations using energy. On the other hand, hospitals are

  8. Atmospheric pollution and heating plants in urban area. What technical solutions for the coal and the heavy oil? For which costs?; Pollution atmospherique et chaufferies en milieu urbain. Quelles solutions techniques pour le charbon et le fioul lourd?. A quel couts?

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    In France, furnaces fed with coal and heavy fuel and established in urban area, are bound by many restraints: a reinforcement of the regulations on atmospheric emissions, a strong social demand bound to the urban air quality improvement and a necessary costs mastership. So buildings managers and persons responsible for district heating are confronted with technical and strategical choices. To answer their questions ADEME organized a day of information around four main themes: the urban heating in France, actions on fuels, possible technics for the smokes desulfurization and nitrogen oxides reduction, costs and financing of the solutions. (A.L.B.)

  9. High-performance commercial building systems

    Energy Technology Data Exchange (ETDEWEB)

    Selkowitz, Stephen

    2003-10-01

    This report summarizes key technical accomplishments resulting from the three year PIER-funded R&D program, ''High Performance Commercial Building Systems'' (HPCBS). The program targets the commercial building sector in California, an end-use sector that accounts for about one-third of all California electricity consumption and an even larger fraction of peak demand, at a cost of over $10B/year. Commercial buildings also have a major impact on occupant health, comfort and productivity. Building design and operations practices that influence energy use are deeply engrained in a fragmented, risk-averse industry that is slow to change. Although California's aggressive standards efforts have resulted in new buildings designed to use less energy than those constructed 20 years ago, the actual savings realized are still well below technical and economic potentials. The broad goal of this program is to develop and deploy a set of energy-saving technologies, strategies, and techniques, and improve processes for designing, commissioning, and operating commercial buildings, while improving health, comfort, and performance of occupants, all in a manner consistent with sound economic investment practices. Results are to be broadly applicable to the commercial sector for different building sizes and types, e.g. offices and schools, for different classes of ownership, both public and private, and for owner-occupied as well as speculative buildings. The program aims to facilitate significant electricity use savings in the California commercial sector by 2015, while assuring that these savings are affordable and promote high quality indoor environments. The five linked technical program elements contain 14 projects with 41 distinct R&D tasks. Collectively they form a comprehensive Research, Development, and Demonstration (RD&D) program with the potential to capture large savings in the commercial building sector, providing significant economic benefits to

  10. Reconstruction of Building Outlines in Dense Urban Areas Based on LIDAR Data and Address Points

    Science.gov (United States)

    Jarzabek-Rychard, M.

    2012-07-01

    The paper presents a comprehensive method for automated extraction and delineation of building outlines in densely built-up areas. A novel approach to outline reconstruction is the use of geocoded building address points. They give information about building location thus highly reduce task complexity. Reconstruction process is executed on 3D point clouds acquired by airborne laser scanner. The method consists of three steps: building detection, delineation and contours refinement. The algorithm is tested against a data set that presents the old market town and its surroundings. The results are discussed and evaluated by comparison to reference cadastral data.

  11. Comparison of Uncertainty of Two Precipitation Prediction Models at Los Alamos National Lab Technical Area 54

    Energy Technology Data Exchange (ETDEWEB)

    Shield, Stephen Allan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dai, Zhenxue [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-08-18

    Meteorological inputs are an important part of subsurface flow and transport modeling. The choice of source for meteorological data used as inputs has significant impacts on the results of subsurface flow and transport studies. One method to obtain the meteorological data required for flow and transport studies is the use of weather generating models. This paper compares the difference in performance of two weather generating models at Technical Area 54 of Los Alamos National Lab. Technical Area 54 is contains several waste pits for low-level radioactive waste and is the site for subsurface flow and transport studies. This makes the comparison of the performance of the two weather generators at this site particularly valuable.

  12. Subsurface contamination focus area technical requirements. Volume II

    International Nuclear Information System (INIS)

    Nickelson, D.; Nonte, J.; Richardson, J.

    1996-10-01

    This is our vision, a vision that replaces the ad hoc or open-quotes delphiclose quotes method which is to get a group of open-quotes expertsclose quotes together and make decisions based upon opinion. To fulfill our vision for the Subsurface Contaminants Focus Area (SCFA), it is necessary to generate technical requirements or performance measures which are quantitative or measurable. Decisions can be supported if they are based upon requirements or performance measures which can be traced to the origin (documented) and are verifiable, i.e., prove that requirements are satisfied by inspection (show me), demonstration, analysis, monitoring, or test. The data from which these requirements are derived must also reflect the characteristics of individual landfills or plumes so that technologies that meet these requirements will necessarily work at specific sites. Other subjective factors, such as stakeholder concerns, do influence decisions. Using the requirements as a basic approach, the SCFA can depend upon objective criteria to help influence the areas of subjectivity, like the stakeholders. In the past, traceable requirements were not generated, probably because it seemed too difficult to do so. There are risks that the requirements approach will not be accepted because it is new and represents a departure from the historical paradigm

  13. Subsurface contamination focus area technical requirements. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Nickelson, D.; Nonte, J.; Richardson, J.

    1996-10-01

    This is our vision, a vision that replaces the ad hoc or {open_quotes}delphi{close_quotes} method which is to get a group of {open_quotes}experts{close_quotes} together and make decisions based upon opinion. To fulfill our vision for the Subsurface Contaminants Focus Area (SCFA), it is necessary to generate technical requirements or performance measures which are quantitative or measurable. Decisions can be supported if they are based upon requirements or performance measures which can be traced to the origin (documented) and are verifiable, i.e., prove that requirements are satisfied by inspection (show me), demonstration, analysis, monitoring, or test. The data from which these requirements are derived must also reflect the characteristics of individual landfills or plumes so that technologies that meet these requirements will necessarily work at specific sites. Other subjective factors, such as stakeholder concerns, do influence decisions. Using the requirements as a basic approach, the SCFA can depend upon objective criteria to help influence the areas of subjectivity, like the stakeholders. In the past, traceable requirements were not generated, probably because it seemed too difficult to do so. There are risks that the requirements approach will not be accepted because it is new and represents a departure from the historical paradigm.

  14. Straw insulated buildings. Nature building materials; Strohgedaemmte Gebaeude. Naturbaustoffe

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-06-01

    Straw is one of the major agricultural by-products and is mainly used as litter in animal husbandry and to compensate the balance of humus. A relatively recent development is the use of straw bales for the construction of buildings. The brochure under consideration documents the technical development of straw construction in Germany. Possibilities of the use of straw in single family homes up to commercial buildings are described.

  15. Delivering competence based training and capacity building to support sustainable uranium mining in less prepared areas

    International Nuclear Information System (INIS)

    Miko Dit Angoula, I.; Tulsidas, H.

    2014-01-01

    The IAEA project “Supporting sustainable uranium mining in less prepared areas” consists of a 3-year catalytic training and capacity building of a range of work packages/tasks targeted on technical, operational, regulatory, environmental, stakeholders and governance needs in uranium mining of African francophone uranium producer or potential producer countries. The project is externally funded by a contribution from the USA. The scope is defined by the identification and the delivery of training and further capacity-building measures to enhance national and regional preparedness in these francophone Member States for the conduct of sustainable uranium mining and production, with particular reference to environmental, social, economic issues and good governance within the context of fostering good, safe practices in the comprehensive extraction of all possible economic resources from the mining process.

  16. The Consortium of Advanced Residential Buildings (CARB) - A Building America Energy Efficient Housing Partnership

    Energy Technology Data Exchange (ETDEWEB)

    Robb Aldrich; Lois Arena; Dianne Griffiths; Srikanth Puttagunta; David Springer

    2010-12-31

    This final report summarizes the work conducted by the Consortium of Advanced Residential Buildings (CARB) (http://www.carb-swa.com/), one of the 'Building America Energy Efficient Housing Partnership' Industry Teams, for the period January 1, 2008 to December 31, 2010. The Building America Program (BAP) is part of the Department of Energy (DOE), Energy Efficiency and Renewable Energy, Building Technologies Program (BTP). The long term goal of the BAP is to develop cost effective, production ready systems in five major climate zones that will result in zero energy homes (ZEH) that produce as much energy as they use on an annual basis by 2020. CARB is led by Steven Winter Associates, Inc. with Davis Energy Group, Inc. (DEG), MaGrann Associates, and Johnson Research, LLC as team members. In partnership with our numerous builders and industry partners, work was performed in three primary areas - advanced systems research, prototype home development, and technical support for communities of high performance homes. Our advanced systems research work focuses on developing a better understanding of the installed performance of advanced technology systems when integrated in a whole-house scenario. Technology systems researched included: - High-R Wall Assemblies - Non-Ducted Air-Source Heat Pumps - Low-Load HVAC Systems - Solar Thermal Water Heating - Ventilation Systems - Cold-Climate Ground and Air Source Heat Pumps - Hot/Dry Climate Air-to-Water Heat Pump - Condensing Boilers - Evaporative condensers - Water Heating CARB continued to support several prototype home projects in the design and specification phase. These projects are located in all five program climate regions and most are targeting greater than 50% source energy savings over the Building America Benchmark home. CARB provided technical support and developed builder project case studies to be included in near-term Joule Milestone reports for the following community scale projects: - SBER Overlook at

  17. B-WEST Regional Workforce Training Center. Building Workers Entering Skilled Trades. Employer Training Guide.

    Science.gov (United States)

    Portland Community Coll., OR.

    This guide, which was developed during the B-WEST (Building Workers Entering Skilled Trades) project, includes materials for use in training and providing on-site consultations to contractors, managers, supervisors, office/technical staff, and others in two areas: diversity in the workplace and sexual harassment in the workplace. Part 1, which…

  18. Establishment of experimental equipments in irradiation technology development building

    International Nuclear Information System (INIS)

    Ishida, Takuya; Tanimoto, Masataka; Shibata, Akira; Kitagishi, Shigeru; Saito, Takashi; Ohmi, Masao; Nakamura, Jinichi; Tsuchiya, Kunihiko

    2011-06-01

    The Neutron Irradiation and Testing Reactor Center has developed new irradiation technologies to provide irradiation data with high technical value for the resume of the Japan Materials Testing Reactor (JMTR). For the purpose to perform assembling of capsules, materials tests, materials inspection and analysis of irradiation specimens for the development of irradiation capsules, improvement and maintenance of facilities were performed. From the viewpoint of effective use of existing buildings in the Oarai research and development center, the RI application development building was refurbished and maintained for above-mentioned purpose. The RI application development building is a released controlled area, and was used as storage of experimental equipments and stationeries. The building was named 'Irradiation Technology Development Building' after it refurbished and maintained. Eight laboratories were maintained based on the purpose of use, and the installation of the experimental apparatuses was started. A basic management procedure of the Irradiation Technology Development Building was established and has been operated. This report describes the refurbish work of the RI application development building, the installation and operation method of the experimental apparatuses and the basic management procedure of the Irradiation Technology Development Building. (author)

  19. BUILDING "BRIDGES" WITH QUALITY ASSURANCE

    Science.gov (United States)

    The papr describes how, rather than building "bridges" across centuries, quality assurance (QA) personnel have the opportunity to build bridges across technical disciplines, between public and private organizations, and between different QA groups. As reviewers and auditors of a...

  20. Technical area status report for low-level mixed waste final waste forms

    International Nuclear Information System (INIS)

    Mayberry, J.L.; DeWitt, L.M.; Darnell, R.

    1993-08-01

    The Final Waste Forms (FWF) Technical Area Status Report (TASR) Working Group, the Vitrification Working Group (WG), and the Performance Standards Working Group were established as subgroups to the FWF Technical Support Group (TSG). The FWF TASR WG is comprised of technical representatives from most of the major DOE sites, the Nuclear Regulatory Commission (NRC), the EPA Office of Solid Waste, and the EPA's Risk Reduction Engineering Laboratory (RREL). The primary activity of the FWF TASR Working Group was to investigate and report on the current status of FWFs for LLNM in this TASR. The FWF TASR Working Group determined the current status of the development of various waste forms described above by reviewing selected articles and technical reports, summarizing data, and establishing an initial set of FWF characteristics to be used in evaluating candidate FWFS; these characteristics are summarized in Section 2. After an initial review of available information, the FWF TASR Working Group chose to study the following groups of final waste forms: hydraulic cement, sulfur polymer cement, glass, ceramic, and organic binders. The organic binders included polyethylene, bitumen, vinyl ester styrene, epoxy, and urea formaldehyde. Section 3 provides a description of each final waste form. Based on the literature review, the gaps and deficiencies in information were summarized, and conclusions and recommendations were established. The information and data presented in this TASR are intended to assist the FWF Production and Assessment TSG in evaluating the Technical Task Plans (TTPs) submitted to DOE EM-50, and thus provide DOE with the necessary information for their FWF decision-making process. This FWF TASR will also assist the DOE and the MWIP in establishing the most acceptable final waste forms for the various LLMW streams stored at DOE facilities

  1. Technical and legal considerations and solutions in the area of battery charging for electric vehicles

    Science.gov (United States)

    Juda, Z.

    2016-09-01

    The issue of protecting health of residents of urbanized areas from the effect of excessive particulate matter and toxic components of car exhaust gases imposes the need of introduction of clean electric vehicles to the market. The increasing market availability of electric vehicles, especially in the segment of short-range (neighborhood) vehicles is followed by development of new and advanced infrastructure solutions. This also applies to the increasingly popular hybrid vehicles PHEV (Plug-in Hybrid Electric Vehicles). However, problems with the existing designs are primarily associated with limited driving range on a single battery charge, the density of charging stations in urban and suburban area, energy system efficiency due to increased electricity demand and the unification of solutions for charging stations, on-board chargers and the necessary accessories. Technical solutions are dependent on many factors, including the type and size of battery in the vehicle and access to power grid with increased load capacity. The article discusses the legal and technical actions outlined in the above directions. It shows the available and planned solutions in this area.

  2. Building energy, building leadership : recommendations for the adoption, development, and implementation of a commercial building energy code in Manitoba

    Energy Technology Data Exchange (ETDEWEB)

    Akerstream, T. [Manitoba Hydro, Winnipeg, MB (Canada); Allard, K. [City of Thompson, Thompson, MB (Canada); Anderson, N.; Beacham, D. [Manitoba Office of the Fire Commissioner, Winnipeg, MB (Canada); Andrich, R. [The Forks North Portage Partnership, MB (Canada); Auger, A. [Natural Resources Canada, Ottawa, ON (Canada). Office of Energy Efficiency; Downs, R.G. [Shindico Realty Inc., Winnipeg, MB (Canada); Eastwood, R. [Number Ten Architectural Group, Winnipeg, MB (Canada); Hewitt, C. [SMS Engineering Ltd., Winnipeg, MB (Canada); Joshi, D. [City of Winnipeg, Winnipeg, MB (Canada); Klassen, K. [Manitoba Dept. of Energy Science and Technology, Winnipeg, MB (Canada); Phillips, B. [Unies Ltd., Winnipeg, MB (Canada); Wiebe, R. [Ben Wiebe Construction Ltd., Winnipeg, MB (Canada); Woelk, D. [Bockstael Construction Ltd., Winnipeg, MB (Canada); Ziemski, S. [CREIT Management LLP, Winnipeg, MB (Canada)

    2006-09-15

    This report presented a strategy and a set of recommendations for the adoption, development and implementation of an energy code for new commercial construction in Manitoba. The report was compiled by an advisory committee comprised of industry representatives and government agency representatives. Recommendations were divided into 4 categories: (1) advisory committee recommendations; (2) code adoption recommendations; (3) code development recommendations; and (4) code implementation recommendations. It was suggested that Manitoba should adopt an amended version of the Model National Energy Code for Buildings (1997) as a regulation under the Buildings and Mobile Homes Act. Participation in a national initiative to update the Model National Energy Code for Buildings was also advised. It was suggested that the energy code should be considered as the first step in a longer-term process towards a sustainable commercial building code. However, the code should be adopted within the context of a complete market transformation approach. Other recommendations included: the establishment of a multi-stakeholder energy code task group; the provision of information and technical resources to help build industry capacity; the establishment of a process for energy code compliance; and an ongoing review of the energy code to assess impacts and progress. Supplemental recommendations for future discussion included the need for integrated design by building design teams in Manitoba; the development of a program to provide technical assistance to building design teams; and collaboration between post-secondary institutions to develop and deliver courses on integrated building design to students and professionals. 17 refs.

  3. The effects of road building on arbuscular mycorrhizal fungal diversity in Huangshan Scenic Area.

    Science.gov (United States)

    Yang, Anna; Tang, Dongmei; Jin, Xiulong; Lu, Lin; Li, Xiaohong; Liu, Kun

    2018-01-22

    Arbuscular mycorrhizal (AM) fungi are vital soil microbes that connect many individual plants into a large functional organism via a vast mycelial network under the ground. In this study, the changes of soil AM fungal community in response to road-building disturbance caused by tourism development in Huangshan (Yellow Mountain) Scenic Area are assessed. Road building have brought negative effects on AM fungal community, inducing lower diversity parameters, including species number, spore density and diversity indices. However, the dominant genus and species of AM fungi which play key roles in the AM fungal community composition are quite similar before and after road building. Moreover, there are no significant differences in species richness of AM fungi associated with plants, suggesting the tolerance of AM fungal community to the disturbance of road building.

  4. Guide for a building energy label. Promoting bio-climatic and solar construction and renovation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    Technically speaking, building experts have the knowledge to deal with thermal inertia of buildings, solar gains, insulation, efficient ventilation, and daylighting... to get low energy buildings that provide comfort for the users. Buildings should always be designed according to the specificities of the local climate, according to a ''solar and bio-climatic construction'' approach. It is not always possible to fully apply these principles, particularly in urban areas with high density. However, this is unacceptable to keep building with such errors as insufficient insulation and direct electrical heating, single glazing, thermal bridges, low efficiency heating systems. This guide aims at encouraging the building experts to take into account the energy efficiency. Implementing a building energy label will allow general public to be aware of this issue and then, and will then lead to develop better practices. (author)

  5. Wind-powered electrical systems : highway rest areas, weigh stations, and team section buildings.

    Science.gov (United States)

    2009-02-01

    This project considered the use of wind for providing electrical power at Illinois Department of Transportation : (IDOT) highway rest areas, weigh stations, and team section buildings. The goal of the project was to determine : the extent to which wi...

  6. Analysis on Zero Energy Consumption Strategy for Office Buildings Lighting in Lianyungang Area

    Science.gov (United States)

    Wu, Dongmei

    2018-01-01

    In recent years, the energy-saving environmental protection has aroused the people’s high concern, and set off a new application practice in China. By analyzing the advantages of the illumination condition in Lianyungang area and combining the content and form of office space, the author puts forward a series of ways and means of energy saving in office building lighting, in order to provide a way for reference to the goal of building Zero energy consumption in the office space environment under the background of green architecture.

  7. Technical-financial evaluation of rainwater harvesting systems in commercial buildings-case ase studies from Sonae Sierra in Portugal and Brazil.

    Science.gov (United States)

    Sousa, Vitor; Silva, Cristina Matos; Meireles, Inês C

    2017-11-10

    Water is an essential and increasingly scarce resource that should be preserved. The evolution of the human population and communities has contributed to the global decrease of potable water availability and the reduction of its consumption is now compulsory. Rainwater harvesting systems (RWHS) are emerging as a viable alternative source for water consumption in non-potable uses. The present study aims to contribute to the promotion of water efficiency, focusing on the application of rainwater harvesting systems in commercial buildings, and comprises four stages: (i) development of a technical evaluation tool to aid the design of RWHS and support their financial evaluation; (ii) validation of the tool using operational data from an existing RWHS installed at Colombo Shopping Center, in Lisbon, Portugal; (iii) assessment of the sensibility of the technical evaluation tool results to the variation of the inputs, namely the precipitation and consumption, through a parametric analysis for the Colombo Shopping Center; and (iv) comparison of the performance and financial feasibility of hypothetical RWHS in two existing commercial buildings. The technical tool was applied to two Sonae Sierra's shopping centers, one in Portugal and one in Brazil. The installation of a 200-m 3 tank is advised for the first case study, allowing non-potable water savings of 60% but a payback period of about 19 years. In the Brazilian shopping, the implementation of a tank with a capacity ranging from 100 to 400 m 3 leads to non-potable savings between 20 and 50%, but with smaller payback period, under 2 years, due to the relatively lower investment costs and higher water fees.

  8. Brief Discussion on Green Building Materials

    International Nuclear Information System (INIS)

    Cai, Jia-wei; Sun, Jian

    2014-01-01

    With more and more emphasizes on the environment and resources, the concept of green buildings has been widely accepted. Building materials are vectors of architectures, only if green building materials and related technical means are used, can we construct green buildings to achieve the purpose of energy conservation and environmental protection. This paper introduces the relationship between green building materials and green buildings, the current situation of green building materials in China, as well as the measures to accelerate the development of green building materials

  9. Special Analysis: 2017-001 Disposal of Drums Containing Enriched Uranium in Pit 38 at Technical Area 54, Area G

    Energy Technology Data Exchange (ETDEWEB)

    Birdsell, Kay Hanson [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Stauffer, Philip H. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); French, Sean B. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-05

    Los Alamos National Laboratory (LANL) generates radioactive waste as a result of various activities. Operational waste is generated from a wide variety of research and development activities including nuclear weapons development, energy production, and medical research. Environmental restoration (ER), and decontamination and decommissioning (D&D) waste is generated as contaminated sites and facilities at LANL undergo cleanup or remediation. The majority of this waste is low-level radioactive waste (LLW) and is disposed of at the Technical Area 54 (TA-54), Area G disposal facility. This special analysis, SA 2017-001, evaluates the potential impacts of disposing of this waste in Pit 38 at Area G based on the assumptions that form the basis of the Area G PA/CA. Section 2 describes the methods used to conduct the analysis; the results of the evaluation are provided in Section 3; and conclusions and recommendations are provided in Section 4.

  10. Capacity Building Imperatives for Developing Science, Technical ...

    African Journals Online (AJOL)

    ... of white-collar jobs, and lack of productive skills for self-employment among graduates. The educational system at that time could not solve the mounting national problem. This was the major purpose why the National Policy on Education was launched in 1977 with great emphasis on Vocational and Technical education ...

  11. EXPERIMENTAL CALIBRATION OF UNDERGROUND HEAT TRANSFER MODELS UNDER A WINERY BUILDING IN A RURAL AREA

    Directory of Open Access Journals (Sweden)

    Francesco Tinti

    2017-01-01

    Full Text Available Ground temperature and hydrogeological conditions are key parameters for many engineering applications, such as the design of building basements and underground spaces and the assessment of shallow geothermal energy potential. Especially in urban areas, in the very shallow depths, it is diffi cult to fi nd natural undisturbed underground thermal conditions because of anthropic interventions. The assessment of underground behaviour in disturbed conditions will become more and more relevant because of increasing awareness to energy effi ciency and renewable energy topics. The purpose of this paper is to show a three-dimensional representation - based on models calibrated on experimental data - of the underground thermal behaviour aff ected by a building in a rural area in Italy. Temperature varies in space and time and it depends on ground, climate and building characteristics, and all these parameters are taken into account by the seasonal periodic modelling implemented. The results obtained in a context of low urbanization indirectly suggest the importance of these eff ects in dense urban areas; taking greater account of these aspects could lead to improvements in the design of underground spaces and geo-exchanger fi elds for geothermal energy exploitation.

  12. A Real-Time Energy Consumption Simulation and Comparison of Buildings in Different Construction Years in the Olympic Central Area in Beijing

    Directory of Open Access Journals (Sweden)

    Chen Xu

    2017-12-01

    Full Text Available Energy consumed the in urban sector accounts for a large proportion of total world delivered energy consumption. Residential building energy consumption is an important part of urban energy consumption. However, there are few studies focused on this issue and that have simulated the energy consumption of residential buildings using questionnaire data. In this research, an eQUEST study was conducted for different residential buildings in the Olympic Central Area in Beijing. Real-time meteorological observation data and an actual energy consumption schedule generated by questionnaire data were used to improve the eQUEST model in the absence of actual energy consumption data. The simulated total energy consumption of residential buildings in the case area in 2015 is 21,262.28 tce, and the average annual energy consumption per unit area is 20.09 kgce/(m2·a. Space heating accounted for 45% of the total energy consumption as the highest proportion, and the second highest was household appliances, which accounted for 20%. The results showed that old residential buildings, multi-storey buildings and large-sized apartment buildings consume more energy. The internal units, building height, per capita construction area, the number of occupants and length of power use had significant impact on residential energy consumption. The result of this study will provide practical reference for energy saving reconstruction of residential buildings in Beijing.

  13. Technical Basis - Spent Nuclear Fuels (SNF) Project Radiation and Contamination Trending Program

    International Nuclear Information System (INIS)

    ELGIN, J.C.

    2000-01-01

    This report documents the technical basis for the Spent Nuclear Fuel (SNF) Program radiation and contamination trending program. The program consists of standardized radiation and contamination surveys of the KE Basin, radiation surveys of the KW basin, radiation surveys of the Cold Vacuum Drying Facility (CVD), and radiation surveys of the Canister Storage Building (CSB) with the associated tracking. This report also discusses the remainder of radiological areas within the SNFP that do not have standardized trending programs and the basis for not having this program in those areas

  14. Glovebox glove change program at Technical Area 55, Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Olivas, J.D.; Burkett, B.O.; Weier, D.R.

    1992-01-01

    A formal glovebox glove change program is planned for the the gloveboxes in technical area 55 at the Los Alamos National laboratory. The program will increase worker safety by reducing the chance of having worn out gloves in service. The Los Alamos program is based on a similar successful program at the Rocky Flats Plant in Golden, Colorado. Glove change frequencies at Rocky Flats were determined statistically, and are based on environmental factors the glovebox gloves are subjected to

  15. Diagnosing in building main pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Telegin, L.G.; Gorelov, A.S.; Kurepin, B.N.; Orekhov, V.I.; Vasil' yev, G.G.; Yakovlev, Ye. I.

    1984-01-01

    General principles are examined for technical diagnosis in building main pipelines. A technique is presented for diagnosis during construction, as well as diagnosis of the technical state of the pipeline-construction machines and mechanisms. The survey materials could be used to set up construction of main pipelines.

  16. Treatment of Chlorinated Solvents in Groundwater Beneath an Occupied Building at the Young-Rainey STAR Center, Pinellas, FL

    Energy Technology Data Exchange (ETDEWEB)

    Daniel, Joe [Navarro Research and Engineering; Surovchak, Scott [Dept. of Energy (DOE), Legacy Management; Tabor, Charles [Navarro Research and Engineering

    2016-03-01

    Groundwater contamination, consisting of two dissolved-phase plumes originating from chlorinated solvent source areas, in the southeastern portion of the Young- Rainey Star Center (also known as the Pinellas County, Florida, Site) in Largo, Florida, has migrated beyond the property boundary, beneath the roadways, and beneath adjacent properties to the south and east. Groundwater contamination will persist as long as the onsite contaminant source remains. The origin of the contamination appears to be multiple long-term point sources beneath Building 100, a 4.5 ha (11 acre) building that housed manufacturing facilities during US DOE operations at the site. The site is now owned by Pinellas County, and most of the space inside the building is leased to private companies, so DOE chose not to conduct characterization or remediation through the floor of the building, instead choosing to conduct all work from outside the building. Injection of emulsified soybean oil and a microbial culture has been used at other areas of the site to accelerate naturally occurring bacterial processes that degrade groundwater contaminants to harmless compounds, and that same approach was chosen for this task. The technical approach consisted of installing horizontal wells from outside the building footprint, extending through and around the identified subsurface treatment areas, and terminating beneath the building. Two 107 m (350 ft) long wells, two 122 m (400 ft) long wells, and four 137 m (450 ft) long wells have been installed to intersect the inferred source areas and confirmed contaminant plumes beneath the building. DOE then injected emulsified vegetable oil and a microbial culture into the horizontal wells at each of several target areas beneath the building where the highest groundwater contaminant concentrations have been detected. The target areas are the northwest corner of the building between the old drum storage pad locations and monitoring well PIN12-S35B, the vicinity of

  17. Subsurface Contaminant Focus Area: Monitored Natural Attenuation (MNA)--Programmatic, Technical, and Regulatory Issues

    Energy Technology Data Exchange (ETDEWEB)

    Krupka, Kenneth M.; Martin, Wayne J.

    2001-07-23

    Natural attenuation processes are commonly used for remediation of contaminated sites. A variety of natural processes occur without human intervention at all sites to varying rates and degrees of effectiveness to attenuate (decrease) the mass, toxicity, mobility, volume, or concentration of organic and inorganic contaminants in soil, groundwater, and surface water systems. The objective of this review is to identify potential technical investments to be incorporated in the Subsurface Contaminant Focus Area Strategic Plan for monitored natural attenuation. When implemented, the technical investments will help evaluate and implement monitored natural attenuation as a remediation option at DOE sites. The outcome of this review is a set of conclusions and general recommendations regarding research needs, programmatic guidance, and stakeholder issues pertaining to monitored natural attenuation for the DOE complex.

  18. Earthquake disaster simulation of civil infrastructures from tall buildings to urban areas

    CERN Document Server

    Lu, Xinzheng

    2017-01-01

    Based on more than 12 years of systematic investigation on earthquake disaster simulation of civil infrastructures, this book covers the major research outcomes including a number of novel computational models, high performance computing methods and realistic visualization techniques for tall buildings and urban areas, with particular emphasize on collapse prevention and mitigation in extreme earthquakes, earthquake loss evaluation and seismic resilience. Typical engineering applications to several tallest buildings in the world (e.g., the 632 m tall Shanghai Tower and the 528 m tall Z15 Tower) and selected large cities in China (the Beijing Central Business District, Xi'an City, Taiyuan City and Tangshan City) are also introduced to demonstrate the advantages of the proposed computational models and techniques. The high-fidelity computational model developed in this book has proven to be the only feasible option to date for earthquake-induced collapse simulation of supertall buildings that are higher than 50...

  19. Technical safety appraisal: Buildings 776/777 Rocky Flats Plant

    Energy Technology Data Exchange (ETDEWEB)

    Field, H C

    1988-03-01

    Buildings 776/777 at the Rocky Flats Plant are major components of the production complex at the plant site. They have been in operation since 1957. The operations taking place in the buildings are nuclear weapons production support, processing of weapons assemblies returned from Pantex, waste processing, research and development in support of production, special projects, and those generated by support groups, such as maintenance. The appraisal team identified nine deficiencies that it believed required prompt attention. DOE management for EH, the program office (Defense Programs), and the field office analyzed the information provided by the appraisal team and instituted compensatory measures for closer monitoring of contractor activities by knowledgeable DOE staff and staff from other sites. Concurrently, the contractor was requested to address both short-term and long-term remedial measures to correct the identified issues as well as the underlying problems. The contractor has provided his action plan, which is included. This plan was under evaluation by EH and the DOE program office at the time this report was prepared. In addressing the major areas of concern identified above, a well as the specific deficiencies identified by the appraisal team, the contractor and the field office are cautioned to search for the root causes for the problems and to direct corrective actions to those root causes rather than solely to the symptoms to assure the sustainability of the improvements being made. The results of prior TSAs led DOE to conclude that previous corrective actions were not sufficient in that a large number of the individual findings are recurrent. Pending completion of remedial actions over the next few months, enhanced DOE oversight of the contractor is warranted.

  20. Technical safety appraisal: Buildings 776/777 Rocky Flats Plant

    International Nuclear Information System (INIS)

    Field, H.C.

    1988-03-01

    Buildings 776/777 at the Rocky Flats Plant are major components of the production complex at the plant site. They have been in operation since 1957. The operations taking place in the buildings are nuclear weapons production support, processing of weapons assemblies returned from Pantex, waste processing, research and development in support of production, special projects, and those generated by support groups, such as maintenance. The appraisal team identified nine deficiencies that it believed required prompt attention. DOE management for EH, the program office (Defense Programs), and the field office analyzed the information provided by the appraisal team and instituted compensatory measures for closer monitoring of contractor activities by knowledgeable DOE staff and staff from other sites. Concurrently, the contractor was requested to address both short-term and long-term remedial measures to correct the identified issues as well as the underlying problems. The contractor has provided his action plan, which is included. This plan was under evaluation by EH and the DOE program office at the time this report was prepared. In addressing the major areas of concern identified above, a well as the specific deficiencies identified by the appraisal team, the contractor and the field office are cautioned to search for the root causes for the problems and to direct corrective actions to those root causes rather than solely to the symptoms to assure the sustainability of the improvements being made. The results of prior TSAs led DOE to conclude that previous corrective actions were not sufficient in that a large number of the individual findings are recurrent. Pending completion of remedial actions over the next few months, enhanced DOE oversight of the contractor is warranted

  1. Moisture Monitoring at Area G, Technical Area 54, Los Alamos National Laboratory, 2016 Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Levitt, Daniel Glenn [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Birdsell, Kay Hanson [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Jennings, Terry L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); French, Sean B. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-01-17

    Hydrological characterization and moisture monitoring activities provide data required for evaluating the transport of subsurface contaminants in the unsaturated and saturated zones beneath Area G, and for the Area G Performance Assessment and Composite Analysis. These activities have been ongoing at Area G, Technical Area 54 of the Los Alamos National Laboratory since waste disposal operations began in 1957. This report summarizes the hydrological characterization and moisture monitoring activities conducted at Area G. It includes moisture monitoring data collected from 1986 through 2016 from numerous boreholes and access tubes with neutron moisture meters, as well as data collected by automated dataloggers for water content measurement sensors installed in a waste disposal pit cover, and buried beneath the floor of a waste disposal pit. This report is an update of a nearly identical report by Levitt et al., (2015) that summarized data collected through early 2015; this report includes additional moisture monitoring data collected at Pit 31 and the Pit 38 extension through December, 2016. It also includes information from the Jennings and French (2009) moisture monitoring report and includes all data from Jennings and French (2009) and the Draft 2010 Addendum moisture monitoring report (Jennings and French, 2010). For the 2015 version of this report, all neutron logging data, including neutron probe calibrations, were investigated for quality and pedigree. Some data were recalculated using more defensible calibration data. Therefore, some water content profiles are different from those in the Jennings and French (2009) report. All of that information is repeated in this report for completeness. Monitoring and characterization data generally indicate that some areas of the Area G vadose zone are consistent with undisturbed conditions, with water contents of less than five percent by volume in the top two layers of the Bandelier tuff at Area G. These data also

  2. Regulation proposal for voluntary energy efficiency labelling of commercial buildings

    International Nuclear Information System (INIS)

    Lamberts, Roberto; Goulart, Solange; Carlo, Joyce; Westphal, Fernando

    2006-01-01

    Despite of Brazil not being between the major world energy consumers, the consumption of electricity has significantly increased in the late years. The National Energy Balance of 2005, published by the Brazilian Ministry of Energy, showed an increasing of the participation of electricity in the final energy consumption of 15.7% in 2002 to 16.2% in 2004. Initially, a brief review of the initiatives taken by Brazilian Government aiming to limit and control the energy consumption in buildings is presented. Then, the regulation proposal containing the technical requirements to classify the energy efficiency level of buildings is shown. The purpose of this voluntary regulation is to provide conditions to certify the energy efficiency level of Brazilian buildings (commercial and public). It specifies the methods for energy efficiency rating of buildings and includes requirements to attend energy conservation measures in three main issues: lighting system; air conditioning system and envelope. The regulation applies to large buildings (minimum total area of 500 m 2 or when the energy demand is greater than or equal to 2,3 kV, including: Conditioned buildings; Partially conditioned buildings and Naturally ventilated buildings. (author)

  3. Socio-Technical Structure

    DEFF Research Database (Denmark)

    Rose, Jeremy; Lindgren, Rikard; Henfridsson, Ole

    2004-01-01

    a reference discipline in its own right (in other words a theory exporter), this paper offers an example of integrative theory development. Instead of adapting a theory from another discipline or building a theory from empirical data, we examine the structure concept in some of its various theoretical......When it comes to investigating the relationship between the social and the technical, IS has been a net importer of theories. These theories often carry differing interpretations of central concepts, which then become both confusing and difficult to integrate. In response to calls for IS to become...... adaptations in IS and try to integrate them to produce theory that focuses on IS concerns whilst resolving some of the major areas of contention. Both social and technological versions of structure are investigated through three theoretical IS perspectives drawn from different reference disciplines. The first...

  4. Economic and Technical Investigation of Grey Water Reuse in High-Rise Buildings in Iran

    Directory of Open Access Journals (Sweden)

    Ashkan Rohani Farahmand

    2017-07-01

    Full Text Available Iran is located in an arid and semi-arid zone with limited water resources. In urban areas where water supplies are short, effluents from wastewater treatment plants can be considered as a reliable alternative source to supply water, especially for such urban uses as flushing and landscape irrigation. The effluents can be used to supply the water for textile, chemical, plastic, and construction industries in addition to agricultural irrigation. While these demands can be supplied from non-potable water resources such as treatment effluents, the water required for drinking and cooking that accounts for only a small portion of the total consumption must be supplied from those resources that conform to quality standards. The objective of the present study was to develop incentive plans and innovative designs that would assist builders and inhabitants of high-rise buildings to implement and employ grey water reuse systems. The study also investigated the effects of emoploying two-storage septic tanks to improve such water parameters as BOD, COD, N, P, and TSS. Given the fact that water connection charges in Iran are only a function of total land and building areas with volumetric parameters excluded, the current pricing system for water and sewage connections needs to be revisited and duly adjusted. The additional costs of systems required for segregating black water from grey water and recirculating treated water within the building may not be economically justifiable and, thus, the incentive plans are expected to provide the required justification for both the water industry and the builders.

  5. [Review comments on the Draft DOE Area Recommendation Report for the Crystalline Repository Project]: Final technical report

    International Nuclear Information System (INIS)

    Dutch, S.I.; Stiegliltz, R.D.

    1986-03-01

    Research performed under the grant primarily involved review and comment on the Draft Area Recommendations Report (DARR). However, because data and ''recommendations'' included in the DARR are unquestionably tied to years of research and dozens of technical reports and documents, i.e., Screening Methodologies, Regional characterization Reports, etc., it is essential that consultants to the Menominee Tribe review all the relevant DOE documents, working papers, etc. Given the short period provided for technical comment and limited funds available to the Tribe, a well designed and thorough technical review was (and is) without question impossible. What review and comment that did occur on a geotechnical level is included in this report

  6. Linking Technical Education to Business Growth: A Case Study on Building Technical Skills in India

    OpenAIRE

    Basant, Rakesh; Chandra, Pankaj

    2007-01-01

    Education has been recognized as the most important source of competitive advantage for a nation. It is the key determinant of firm level productivity which in turn drives business growth and profitability. Technical knowledge, in particular, is required both for industrial as well as service development. Technical institutions contribute to the growth of business and industry in a variety of ways. The most influential and direct impact is through their graduates who bring in new skills and p...

  7. Intelligent Facades for High Performance Green Buildings. Final Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Dyson, Anna [Rensselaer Polytechnic Inst., Troy, NY (United States)

    2017-03-01

    Intelligent Facades for High Performance Green Buildings: Previous research and development of intelligent facades systems has been limited in their contribution towards national goals for achieving on-site net zero buildings, because this R&D has failed to couple the many qualitative requirements of building envelopes such as the provision of daylighting, access to exterior views, satisfying aesthetic and cultural characteristics, with the quantitative metrics of energy harvesting, storage and redistribution. To achieve energy self-sufficiency from on-site solar resources, building envelopes can and must address this gamut of concerns simultaneously. With this project, we have undertaken a high-performance building- integrated combined-heat and power concentrating photovoltaic system with high temperature thermal capture, storage and transport towards multiple applications (BICPV/T). The critical contribution we are offering with the Integrated Concentrating Solar Façade (ICSF) is conceived to improve daylighting quality for improved health of occupants and mitigate solar heat gain while maximally capturing and transferring on- site solar energy. The ICSF accomplishes this multi-functionality by intercepting only the direct-normal component of solar energy (which is responsible for elevated cooling loads) thereby transforming a previously problematic source of energy into a high- quality resource that can be applied to building demands such as heating, cooling, dehumidification, domestic hot water, and possible further augmentation of electrical generation through organic Rankine cycles. With the ICSF technology, our team is addressing the global challenge in transitioning commercial and residential building stock towards on-site clean energy self-sufficiency, by fully integrating innovative environmental control systems strategies within an intelligent and responsively dynamic building envelope. The advantage of being able to use the entire solar spectrum for

  8. Modelling technical snow production for skiing areas in the Austrian Alps with the physically based snow model AMUNDSEN

    Science.gov (United States)

    Hanzer, F.; Marke, T.; Steiger, R.; Strasser, U.

    2012-04-01

    Tourism and particularly winter tourism is a key factor for the Austrian economy. Judging from currently available climate simulations, the Austrian Alps show a particularly high vulnerability to climatic changes. To reduce the exposure of ski areas towards changes in natural snow conditions as well as to generally enhance snow conditions at skiing sites, technical snowmaking is widely utilized across Austrian ski areas. While such measures result in better snow conditions at the skiing sites and are important for the local skiing industry, its economic efficiency has also to be taken into account. The current work emerges from the project CC-Snow II, where improved future climate scenario simulations are used to determine future natural and artificial snow conditions and their effects on tourism and economy in the Austrian Alps. In a first step, a simple technical snowmaking approach is incorporated into the process based snow model AMUNDSEN, which operates at a spatial resolution of 10-50 m and a temporal resolution of 1-3 hours. Locations of skiing slopes within a ski area in Styria, Austria, were digitized and imported into the model environment. During a predefined time frame in the beginning of the ski season, the model produces a maximum possible amount of technical snow and distributes the associated snow on the slopes, whereas afterwards, until to the end of the ski season, the model tries to maintain a certain snow depth threshold value on the slopes. Due to only few required input parameters, this approach is easily transferable to other ski areas. In our poster contribution, we present first results of this snowmaking approach and give an overview of the data and methodology applied. In a further step in CC-Snow, this simple bulk approach will be extended to consider actual snow cannon locations and technical specifications, which will allow a more detailed description of technical snow production as well as cannon-based recordings of water and energy

  9. Standardization of green building technologies for environment design

    Directory of Open Access Journals (Sweden)

    Benuzh Andrey

    2016-01-01

    Full Text Available The article describes the structure and field of standardization ISO / TC 205 “Building environment design”, provides examples of green building technologies. The main purpose of the article is to show the interaction between international ISO / TC 205 “Building environment design” and created in Russia in 2016 the Technical Committee of Standardization № 366 “Green technology of the build environment and green innovative products”. Both of these technical committees promote green building technologies for environment design, thereby deal with the negative impact on the environment and the reasons of global warming. Instead of buildings that attempt to suppress and overcome nature, why not design buildings that integrate with the environment, on every possible level? The international standardization work which ISO/TC 205 “Building environment design” performs seeks, in addition to lowering trade barriers for engineering design, to promote and facilitate the design of high performance buildings: higher performing as economic assets for their owners, higher performing as buildings that provide amenable indoor environment for their occupants, and higher performing with respect to resource utilization and environmental impact.

  10. Seismic analysis of a reactor building with eccentric layout

    International Nuclear Information System (INIS)

    Itoh, T.; Deng, D.Z.F.; Lui, K.

    1987-01-01

    Conventional design for a reactor building in a high seismic area has adopted an essentially concentric layout in response to fear of excessive torsional effect due to horizontal seismic load on an eccentric plant. This concentric layout requirement generally results in an inflexible arrangement of the plant facilities and thus increases the plant volume. This study is performed to investigate the effect of eccentricity on the overall seismic structural response and to provide technical information in this regard to substantiate the volume reduction of the overall power plant. The plant layout is evolved from the Bechtel standard plan of a PWR plant by integrating the reactor building and the auxiliary building into a combined building supported on a common basemat. This plant layout is optimized for volume utilization and to reduce the length of piping systems. The mass centers at various elevations of the combined building do not coincide with the rigidity center (RC) of the respective floor and the geometric center of the basemat, thus creating an eccentric response of the building in a seismic environment. Therefore, the torsional effects of the structure have to be taken into account in the seismic analysis

  11. Decreasing of energy consumption for space heating in existing residential buildings

    International Nuclear Information System (INIS)

    Stamov, S.; Zlateva, M.; Gechkov, N.

    2000-01-01

    An analysis is for the technical possibilities for reducing the energy consumption in existing buildings by means of the heat control and measurement. The basic performances of the heat capacity control methods, of the hierarchy structure of the control and of the heat measurement technologies are presented. This paper also presents the results from the long-term investigation of energy consumption for heating. The results area consist of three typical and uniform buildings in the city of Kazanlak (Bulgaria). The outcome of the investigation provides a valuable basis for future decisions to be made concerning reconstruction of heating installations and enables the results to be transferred. (Authors)

  12. Experimental Analyses of Yellow Tuff Spandrels of Post-medieval Buildings in the Naples Area

    International Nuclear Information System (INIS)

    Calderoni, B.; Cordasco, E. A.; Lenza, P.; Guerriero, L.

    2008-01-01

    Experimental analyses have been carried out on tuff masonry specimens in order to investigate the structural behaviour of historical buildings in the Naples area (Southern Italy). Spandrels of post-medieval buildings (late XVI to early XX century) have been analysed, with emphasis on morphological characteristics according to chronological indicators. Results of the experimentation on scaled models (1:10) are discussed and the better behaviour of historical masonry typologies on respect to the modern one is highlighted. Comparison with theoretical formulations of ultimate shear resistance are provided too

  13. Amelioration and retrofitting of educational buildings

    Science.gov (United States)

    Casciati, Fabio; Casciati, Sara

    2018-01-01

    Following a seismic event that occurred years ago in Central Italy, the public opinion was growing and growing a concern on the adequacy of educational buildings all across Italy. This activated several political decisions and a consequent technical effort is in progress. Technically speaking one has to manage the classical problem of retrofitting existing buildings. However, the legal environment goes across national codes, targeted guidelines and the professional need of achieving pragmatic solutions based on ethical and social acceptation schemes.This paper introduces the topic in its worldwide exception and focuses then on some operative aspects in the Italian situation. It outlines the consolidated steps along this technical process and emphasizes the weak aspects one meets when going across the designers' reports.

  14. 76 FR 33332 - Announcement of Funding Awards for the Technical Assistance and Capacity Building under the...

    Science.gov (United States)

    2011-06-08

    ... program knowledge, skills and capacity of CPD's grantees and their partners. Capacity building efforts... several areas including (1) Development Finance, (2) Environmental Review and Compliance, (3) Asset... National Association for Latino TX 900,000 Community Asset Builders. National Center on Family MA 700,000...

  15. US-India Technical Collaboration to Promote Regional Stability

    International Nuclear Information System (INIS)

    Killinger, Mark H.; Griggs, James R.; Apt, Kenneth E.; Doyle, James E.

    2001-01-01

    Two US-India documents were signed in 2000 that provided new impetus for scientific and technical cooperation between the two countries. The first document is the US-India Science and Technology Agreement, which is aimed at 'promoting scientific and technological cooperation between the people of their two countries.' The second is the US-India Joint Statement on Energy and Environment, which states 'the United States and India believe that energy and environment could be one of the most important areas of cooperation between the two countries.' In addition to the work already underway as part of these two agreements, DOE has established a US-India Science and Technology Initiative to utilize the expertise of DOE national laboratories to conduct activities that support US policy objectives in South Asia. PNNL and LANL are working with US agencies and the Indian government and scientific communities to identify appropriate non-sensitive areas for US-Indian technical collaboration. The objectives of such collaboration are to address visible national/international problems, build trust between the United States and India, and contribute to regional stability in South Asia. This paper describes research done on the Indian scientific organization and infrastructure, potential areas for collaboration, the approach for this engagement, and current status of the initiative.

  16. US-INDIA TECHNICAL COLLABORATION TO PROMOTE REGIONAL STABILITY

    International Nuclear Information System (INIS)

    Killinger, M.H.; Griggs, J.R.; Apt, Kenneth E.; Doyle, J.E.

    2001-01-01

    Two US-India documents were signed in 2000 that provided new impetus for scientific and technical cooperation between the two countries. The first document is the US-India Science and Technology Agreement, which is aimed at 'promoting scientific and technological cooperation between the people of their two countries.' The second is the US-India Joint Statement on Energy and Environment, which states 'the United States and India believe that energy and environment could be one of the most important areas of cooperation between the two countries.' In addition to the work already underway as part of these two agreements, the US Department of Energy (DOE) has established a US-India Science and Technology Initiative to utilize the expertise of DOE national laboratories to conduct activities that support US policy objectives in South Asia. PNNL and LANL are working with US government agencies to identify appropriate non-sensitive, non-nuclear areas for US-Indian technical collaboration. The objectives of such collaboration are to address visible national and international problems, build trust between the United States and India, and contribute to regional stability in South Asia. This paper describes the approach for this engagement, the Indian scientific organization and infrastructure, potential areas for collaboration, and current status of the initiative.

  17. Canister Storage Building (CSB) Technical Safety Requirements

    International Nuclear Information System (INIS)

    KRAHN, D.E.

    2000-01-01

    The purpose of this section is to explain the meaning of logical connectors with specific examples. Logical connectors are used in Technical Safety Requirements (TSRs) to discriminate between, and yet connect, discrete Conditions, Required Actions, Completion Times, Surveillances, and Frequencies. The only logical connectors that appear in TSRs are AND and OR. The physical arrangement of these connectors constitutes logical conventions with specific meanings

  18. Differences in bacterial composition between men's and women's restrooms and other common areas within a public building.

    Science.gov (United States)

    Dobbler, Priscila Caroline Thiago; Laureano, Álvaro Macedo; Sarzi, Deise Schroder; Cañón, Ehidy Rocio Peña; Metz, Geferson Fernando; de Freitas, Anderson Santos; Takagaki, Beatriz Midori; D Oliveira, Cristiane Barbosa; Pylro, Victor Satler; Copetti, André Carlos; Victoria, Filipe; Redmile-Gordon, Marc; Morais, Daniel Kumazawa; Roesch, Luiz Fernando Wurdig

    2018-04-01

    Humans distribute a wide range of microorganisms around building interiors, and some of these are potentially pathogenic. Recent research established that humans are the main drivers of the indoor microbiome and up to now significant literature has been produced about this topic. Here we analyzed differences in bacterial composition between men's and women's restrooms and other common areas within the same public building. Bacterial DNA samples were collected from restrooms and halls of a three-floor building from the Federal University of Pampa, RS, Brazil. The bacterial community was characterized by amplification of the V4 region of the 16S rRNA gene and sequencing. Throughout all samples, the most abundant phylum was Proteobacteria, followed by Actinobacteria, Bacteroidetes and Firmicutes. Beta diversity metrics showed that the structure of the bacterial communities were different among the areas and floors tested, however, only 6-9% of the variation in bacterial communities was explained by the area and floors sampled. A few microorganisms showed significantly differential abundance between men's and women's restrooms, but in general, the bacterial communities from both places were very similar. Finally, significant differences among the microbial community profile from different floors were reported, suggesting that the type of use and occupant demographic within the building may directly influence bacterial dispersion and establishment.

  19. Non-technical skills training to enhance patient safety.

    Science.gov (United States)

    Gordon, Morris

    2013-06-01

      Patient safety is an increasingly recognised issue in health care. Systems-based and organisational methods of quality improvement, as well as education focusing on key clinical areas, are common, but there are few reports of educational interventions that focus on non-technical skills to address human factor sources of error. A flexible model for non-technical skills training for health care professionals has been designed based on the best available evidence, and with sound theoretical foundations.   Educational sessions to improve non-technical skills in health care have been described before. The descriptions lack the details to allow educators to replicate and innovate further.   A non-technical skills training course that can be delivered as either a half- or full-day intervention has been designed and delivered to a number of mixed groups of undergraduate medical students and doctors in postgraduate training. Participant satisfaction has been high and patient safety attitudes have improved post-intervention.   This non-technical skills educational intervention has been built on a sound evidence base, and is described so as to facilitate replication and dissemination. With the key themes laid out, clinical educators will be able to build interventions focused on numerous clinical issues that pay attention to human factor contributors to safety. © 2013 John Wiley & Sons Ltd.

  20. Danish building typologies

    DEFF Research Database (Denmark)

    Wittchen, Kim Bjarne; Kragh, Jesper

    The objective of TABULA is to develop a harmonised building typology for European countries. Each national building typology will consist of a set of residential model buildings with characteristic energy-related properties (element areas of the thermal building envelope, U-values, supply system...... efficiencies). The model buildings will each represent a specific construction period of the country in question and a specific building size. Furthermore the number of buildings, flats and the overall floor areas will be given, which are represented by the different building types of the national typologies....

  1. Visual Sample Plan (VSP) Software: Designs and Data Analyses for Sampling Contaminated Buildings

    International Nuclear Information System (INIS)

    Pulsipher, Brent A.; Wilson, John E.; Gilbert, Richard O.; Nuffer, Lisa L.; Hassig, Nancy L.

    2005-01-01

    A new module of the Visual Sample Plan (VSP) software has been developed to provide sampling designs and data analyses for potentially contaminated buildings. An important application is assessing levels of contamination in buildings after a terrorist attack. This new module, funded by DHS through the Combating Terrorism Technology Support Office, Technical Support Working Group, was developed to provide a tailored, user-friendly and visually-orientated buildings module within the existing VSP software toolkit, the latest version of which can be downloaded from http://dqo.pnl.gov/vsp. In case of, or when planning against, a chemical, biological, or radionuclide release within a building, the VSP module can be used to quickly and easily develop and visualize technically defensible sampling schemes for walls, floors, ceilings, and other surfaces to statistically determine if contamination is present, its magnitude and extent throughout the building and if decontamination has been effective. This paper demonstrates the features of this new VSP buildings module, which include: the ability to import building floor plans or to easily draw, manipulate, and view rooms in several ways; being able to insert doors, windows and annotations into a room; 3-D graphic room views with surfaces labeled and floor plans that show building zones that have separate air handing units. The paper will also discuss the statistical design and data analysis options available in the buildings module. Design objectives supported include comparing an average to a threshold when the data distribution is normal or unknown, and comparing measurements to a threshold to detect hotspots or to insure most of the area is uncontaminated when the data distribution is normal or unknown

  2. ASPECTS OF THE INFLUENCE ASSESSMENT OF THE NEW CONSTRUCTION DURING THE RECONSTRUCTION OF URBAN TERRITORY AREAS IN THE DENSE BUILDING CONDITIONS

    Directory of Open Access Journals (Sweden)

    Dmitry Prusov

    2013-10-01

    Full Text Available Normal 0 false false false MicrosoftInternetExplorer4 The scientific substantiation concept has been considered for the urban development and territorial planning reconstruction principles of the urban area sections with dense building and difficult engineering-geological conditions for scientific and technical support of all reconstruction processes and recommendations elaboration for a safe and balanced development of built-up territories and more efficient use of housing estates in the present social and economic conditions. /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Обычная таблица"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;}

  3. US Department of Energy mixed waste characterization, treatment, and disposal focus area technical baseline development process

    International Nuclear Information System (INIS)

    Roach, J.A.; Gombert, D.

    1996-01-01

    The US Department of Energy (DOE) created the Mixed Waste Characterization, Treatment, and Disposal Focus Area (MWFA) to develop and facilitate implementation of technologies required to meet its commitments for treatment of mixed wastes under the Federal Facility Compliance Act (FFCA), and in accordance with the Land Disposal Restrictions (LDR) of the Resource Conservation and Recovery Act (RCRA). Mixed wastes include both mixed low-level waste (MLLW) and mixed transuranic (MTRU) waste. The goal of the MWFA is to develop mixed waste treatment systems to the point of implementation by the Environmental Management (EM) customer. To accomplish this goal, the MWFA is utilizing a three step process. First, the treatment system technology deficiencies were identified and categorized. Second, these identified needs were prioritized. This resulted in a list of technical deficiencies that will be used to develop a technical baseline. The third step, the Technical Baseline Development Process, is currently ongoing. When finalized, the technical baseline will integrate the requirements associated with the identified needs into the planned and ongoing environmental research and technology development activities supported by the MWFA. Completion of this three-step process will result in a comprehensive technology development program that addresses customer identified and prioritized needs. The MWFA technical baseline will be a cost-effective, technically-defensible tool for addressing and resolving DOE's mixed waste problems

  4. Internet-based reservation system (Internet-based control of timers for building technical services) - Final report; Internetbasiertes Reservationssystem (Internetbasierte Einstellung von Zeitsteuerungen haustechnischer Anlagen) - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Huber, A.; Woodtli, M.

    2008-07-01

    A common measure to save energy in buildings is the adjustment of the operating time of the building service facilities to the busy time of the building (i.e. lowering period). For lack of better resources, the general lowering periods in irregularly occupied buildings often are reduced to a minimum or the adjustment of the operating time is completely missing. In order to adjust the operating time optimally to the actual busy time, an internet-based booking system has been developed, which allows users to register a room assignment online. This booking system is linked with the building service facilities. This ensure the optimal setting of the lowering periods and therefore allows saving energy. The technical implementation resulted from a programmable logic controller (PLC) that can be accessed via a web browser. Temperature offset boxes have been added as interface between the PLC and the existing facilities in order that the system is applicable in existing buildings too. The booking system has been installed in two test objects and has also been successfully tested with the responsible staff (caretaker, real estate management). The booking system may be contemplated online: http://www.hetag.ch. (author)

  5. A building characterization-based method for the advancement of knowledge on external architectural features of traditional rural buildings

    Directory of Open Access Journals (Sweden)

    Porto, S. M. C.

    2013-12-01

    Full Text Available The significant role that traditional rural buildings have with regard to environmental conservation and rural development is widely acknowledged by the scientific community. These buildings must be protected from inappropriate building interventions that may stem from their rather superficial knowledge. Therefore, this study was directed towards overcoming such a limitation by developing a method based on traditional rural buildings’ characterization. In particular, the study aimed at the characterization of building materials and techniques used for the construction of a number of building components that make up the external envelope of traditional rural buildings. The application of the method to a homogeneous area of the Etna Regional Park (Italy highlighted the need to improve the technical norms of the park’s Territorial Coordination Plan to respect the building characteristics of the traditional rural buildings located in the protected area.La comunidad científica le atribuye a las construcciones rurales tradicionales un papel fundamental en términos de conservación del medioambiente y de evolución rural. Dichos edificios deben ser protegidos contra obras inapropiadas debidas a un conocimiento más bien superficial. Por lo tanto, el objetivo de este estudio fue el de eliminar dichas limitaciones desarrollando un método basado en la caracterización de las construcciones rurales tradicionales, que puede ser aplicado para mejorar el conocimiento de estas últimas. En particular, el susodicho estudio tiene la finalidad de caracterizar los materiales y las técnicas constructivas a emplear para la construcción de algunos componentes del envoltorio externo de las construcciones rurales tradicionales. La aplicación del método propuesto a una zona homogénea del Parque Regional del Etna (Italia puso de relieve la necesidad de mejorar las normas técnicas del Plan de Coordinación Territorial del parque para respetar las caracter

  6. Discussing simply waste water treatment in building green mine

    International Nuclear Information System (INIS)

    Zhou Yousheng

    2010-01-01

    Analysis simplfy it is important and necessary that uran ore enterprise build the green mine .According to focusing on waste water treatment in building green mine of some uran ore enterprise,analysis the problem in treating mine water, technics waste water, tailings water before remoulding the system of waster water treatment, evaluate the advanced technics, satisfy ability, steady effect, reach the mark of discharge. According to the experimental unit of building the green mine,some uran ore enterprise make the waster water reaching the mark of discharge after remoulding the system of waster water treatment.It provides valuable experienceto uran ore enterprise in building green mine. (authors)

  7. Operation and maintenance of the technical installations in buildings

    DEFF Research Database (Denmark)

    Nielsen, O.(red.)

    The report contains twelve papers from a seminar on operation and maintenance, held at the Danish Building Research Institute in October 1976. The papers deal, among other things, with dimensioning and balancing of pipesystems, design of ventilating systems for adequate operation and maintenance,......, cost and quality in maintenance, maintenance service companies, as well as organization and training for building services maintenance....

  8. Rainfall-induced landslide vulnerability Assessment in urban area reflecting Urban structure and building characteristics

    Science.gov (United States)

    Park, C.; Cho, M.; Lee, D.

    2017-12-01

    Landslide vulnerability assessment methodology of urban area is proposed with urban structure and building charateristics which can consider total damage cost of climate impacts. We used probabilistic analysis method for modeling rainfall-induced shallow landslide susceptibility by slope stability analysis and Monte Carlo simulations. And We combined debris flows with considering spatial movements under topographical condition and built environmental condition. Urban vulnerability of landslide is assessed by two categories: physical demages and urban structure aspect. Physical vulnerability is related to buildings, road, other ubran infra. Urban structure vulnerability is considered a function of the socio-economic factors, trigger factor of secondary damage, and preparedness level of the local government. An index-based model is developed to evaluate the life and indirect damage under landslide as well as the resilience ability against disasters. The analysis was performed in a geographic information system (GIS) environment because GIS can deal efficiently with a large volume of spatial data. The results of the landslide susceptibility assessment were compared with the landslide inventory, and the proposed approach demonstrated good predictive performance. The general trend found in this study indicates that the higher population density areas under a weaker fiscal condition that are located at the downstream of mountainous areas are more vulnerable than the areas in opposite conditions.

  9. Seminar series on `Technical building installations`. The example of refrigeration technology for air conditioning plants. Practice-oriented advanced training at Technische Akademie Esslingen training centre. Seminar series on `Technical building installations`; Lehrgangsreihe ``Technische Gebaeudeausruestung``. Beispiel: Kaeltetechnik in Klimaanlagen. Praxisnahe Fortbildung am Weiterbildungszentrum Technische Akademie Esslingen. Lehrgangsreihe ``Technische Gebaeudeausruestung``

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1995-04-01

    The advanced training on ``Technical Building Installations`` at the Technische Akademie Esslingen has been held regularly over a period of 18 years now. The training lasts several days and comprises a total of 12 courses on the subjects: ventilation and air-conditioning, stages A-D; refrigeration, stage A; refrigeration in air conditioning glants; energy concepts for buildings and industry, stages A and B; heating in old and new buildings; sanitation, stages A and B; and, sanitation in old and new buildings. In the present article the structure of the training is illustrated for the example of refrigeration in air conditioning plants. The article also discusses questions concerning the assessment of the training and its benefit to the participants. (BWI) [Deutsch] Seit nunmehr 18 Jahren wird an der Technischen Akademie Esslingen TAE die mehrtaegige Fortbildungsveranstaltung ``Technische Gebaeudeausruestung`` durchgefuehrt. Insgesamt werden in diesem gesamten Themenkomplex 12 Lehrgaenge angeboten: Raumlufttechnik, Teil A-D; Kaeltetechnik Teil A - Kaeltetechnik in Klimaanlagen, Energiekonzepte fuer Gebaeude und Industrie, Teil A und B, Heiztechnik in Neu- und Altbauten, Sanitaertechnik Teil A und B. Am Beispiel des Themenbereiches Kaeltetechnik in Klimaanlagen wird die Lehrgangsausrichtung dargestellt. Ferner werden Fragen der Lehrgangsbewertung und der Nutzen fuer die Teilnehmer diskutiert. (BWI)

  10. Final Technical Report. Sault Tribe Building Efficiency Audits of Tribally-Owned Governmental Buildings and Residential Tribal Housing

    Energy Technology Data Exchange (ETDEWEB)

    Holt, Jeffrey W. [Sault Sainte Marie Tribe of Chippewa Indians, Marie, MI (United States)

    2015-03-27

    The Tribe is working to reduce energy consumption and expense in Tribally-owned governmental buildings and low income housing sites. In 2009, the Tribe applied to the U. S. Department of Energy for funding to conduct energy audits of Tribally-owned governmental buildings. Findings from the energy audits would define the extent and types of energy efficiency improvements needed, establish a basis for energy priorities, strategies and action plans, and provide a benchmark for measuring improvements from energy efficiency implementations. In 2010, the DOE awarded a grant in the amount of $95,238 to the Tribe to fund the energy audits of nine governmental buildings and to pay for travel expenses associated with attendance and participation at the DOE annual program reviews. In 2011, the Tribe applied for and was awarded a DOE grant in the amount of $75,509 to conduct energy audits of the remaining 30 Tribally-owned governmental buildings. Repeating mobilization steps performed during the first DOE energy audits grant, the Tribe initiated the second round of governmental building energy audits by completing energy auditor procurement. The selected energy auditor successfully passed DOE debarment and Sault Tribe background clearances. The energy audits contract was awarded to U. P. Engineers and Architects, Inc. of Sault Ste. Marie, Michigan. The Tribe continued mobilizing for the energy audits by providing the energy auditor with one year of electric, gas and water utility invoice copies per building, as well as supplemental building information, such as operating hours. The Tribe also contacted building occupants to coordinate scheduling for the on-site energy audit inspections and arranged for facilities management personnel to guide the energy auditor through the buildings and answer questions regarding building systems.

  11. Renewable Energy Applications for Existing Buildings: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Hayter, S. J.; Kandt, A.

    2011-08-01

    This paper introduces technical opportunities, means, and methods for incorporating renewable energy (RE) technologies into building designs and operations. It provides an overview of RE resources and available technologies used successfully to offset building electrical and thermal energy loads. Methods for applying these technologies in buildings and the role of building energy efficiency in successful RE projects are addressed along with tips for implementing successful RE projects.

  12. Mixed waste focus area integrated technical baseline report. Phase I, Volume 2: Revision 0

    International Nuclear Information System (INIS)

    1996-01-01

    This document (Volume 2) contains the Appendices A through J for the Mixed Waste Focus Area Integrated Technical Baseline Report Phase I for the Idaho National Engineering Laboratory. Included are: Waste Type Managers' Resumes, detailed information on wastewater, combustible organics, debris, unique waste, and inorganic homogeneous solids and soils, and waste data information. A detailed list of technology deficiencies and site needs identification is also provided

  13. Analysis of technical-economic requirements for the construction of a solar power plant on the roof of the business building of the Electrical Engineering Institute 'Nikola Tesla'

    OpenAIRE

    Grbić, Maja; Antić, Radoslav; Ponoćko, Jelena; Mikulović, Jovan; Đurišić, Željko

    2014-01-01

    This paper presents an analysis of the technical-economic requirements for the construction of a solar power plant on the roof of the business building of the Electrical Engineering Institute 'Nikola Tesla' in Belgrade. Calculation of solar irradiation is performed and the conceptual design of the disposition of solar panels on the roof of the building is shown as well as their connections to the inverters. Conditions for connecting the plant to the distribution network are checked and an eco...

  14. Low-energy district heating in energy-efficient building areas

    International Nuclear Information System (INIS)

    Dalla Rosa, A.; Christensen, J.E.

    2011-01-01

    This paper presents an innovative low-energy district heating (DH) concept based on low-temperature operation. The decreased heating demand from low-energy buildings affects the cost-effectiveness of traditionally-designed DH systems, so we carried out a case study of the annual energy performance of a low-energy network for low-energy houses in Denmark. We took into account the effect of human behaviour on energy demand, the effect of the number of buildings connected to the network, a socio-economic comparison with ground source heat pumps, and opportunities for the optimization of the network design, and operational temperature and pressure. In the north-European climate, we found that human behaviour can lead to 50% higher heating demand and 60% higher heating power than those anticipated in the reference values in the standard calculations for energy demand patterns in energy-efficient buildings. This considerable impact of human behaviour should clearly be included in energy simulations. We also showed that low-energy DH systems are robust systems that ensure security of supply for each customer in a cost-effective and environmentally friendly way in areas with linear heat density down to 0.20 MWh/(m year), and that the levelized cost of energy in low-energy DH supply is competitive with a scenario based on ground source heat pumps. The investment costs represent up to three quarters of the overall expenditure, over a time horizon of 30 years; so, the implementation of an energy system that fully relies on renewable energy needs substantial capital investment, but in the long term this is sustainable from the environmental and socio-economic points of view. Having demonstrated the value of the low-energy DH concept, we evaluated various possible designs with the aim of finding the optimal solution with regard to economic and energy efficiency issues. Here we showed the advantage of low supply and return temperatures, their effect on energy efficiency and that

  15. A Brief Technical History of the Large-Area Picosecond Photodetector (LAPPD) Collaboration

    Energy Technology Data Exchange (ETDEWEB)

    Adams, B.W.; et al.

    2016-03-06

    The Large Area Picosecond PhotoDetector (LAPPD) Collaboration was formed in 2009 to develop large-area photodetectors capable of time resolutions measured in pico-seconds, with accompanying sub-millimeter spatial resolution. During the next three and one-half years the Collaboration developed the LAPPD design of 20 x 20 cm modules with gains greater than $10^7$ and non-uniformity less than $15\\%$, time resolution less than 50 psec for single photons and spatial resolution of 700~microns in both lateral dimensions. We describe the R\\&D performed to develop large-area micro-channel plate glass substrates, resistive and secondary-emitting coatings, large-area bialkali photocathodes, and RF-capable hermetic packaging. In addition, the Collaboration developed the necessary electronics for large systems capable of precise timing, built up from a custom low-power 15-GigaSample/sec waveform sampling 6-channel integrated circuit and supported by a two-level modular data acquisition system based on Field-Programmable Gate Arrays for local control, data-sparcification, and triggering. We discuss the formation, organization, and technical successes and short-comings of the Collaboration. The Collaboration ended in December 2012 with a transition from R\\&D to commercialization.

  16. Consumer Central Energy Flexibility in Office Buildings

    DEFF Research Database (Denmark)

    Billanes, Joy Dalmacio; Ma, Zheng; Jørgensen, Bo Nørregaard

    2017-01-01

    Energy flexibility in buildings will play an important role in the smart energy system. Office buildings have more potentials to provide energy flexibility to the grid compared to other types of buildings, due to the existing building management, control systems and large energy consumption....... Consumers in office buildings (building owners/managers and occupants) take a main role for adopting and engaging in building energy flexibility. In this paper provides a systematic review of consumer central energy flexibility in office buildings with the discussion of social, technical and business...... can boost energy flexibility in the office buildings....

  17. Technical area status report for waste destruction and stabilization

    International Nuclear Information System (INIS)

    Dalton, J.D.; Harris, T.L.; DeWitt, L.M.

    1993-08-01

    The Office of Environmental Restoration and Waste Management (EM) was established by the Department of Energy (DOE) to direct and coordinate waste management and site remediation programs/activities throughout the DOE complex. In order to successfully achieve the goal of properly managing waste and the cleanup of the DOE sites, the EM was divided into five organizations: the Office of Planning and Resource Management (EM-10); the Office of Environmental Quality Assurance and Resource Management (EM-20); the Office of Waste Operations (EM-30); the Office of Environmental Restoration (EM-40); and the Office of Technology and Development (EM-50). The mission of the Office of Technology Development (OTD) is to develop treatment technologies for DOE's operational and environmental restoration wastes where current treatment technologies are inadequate or not available. The Mixed Waste Integrated Program (MWIP) was created by OTD to assist in the development of treatment technologies for the DOE mixed low-level wastes (MLLW). The MWIP has established five Technical Support Groups (TSGs) whose purpose is to identify, evaluate, and develop treatment technologies within five general technical areas representing waste treatment functions from initial waste handling through generation of final waste forms. These TSGs are: (1) Front-End Waste Handling, (2) Physical/Chemical Treatment, (3) Waste Destruction and Stabilization, (4) Second-Stage Destruction and Offgas Treatment, and (5) Final Waste Forms. This report describes the functions of the Waste Destruction and Stabilization (WDS) group. Specifically, the following items are discussed: DOE waste stream identification; summary of previous efforts; summary of WDS treatment technologies; currently funded WDS activities; and recommendations for future activities

  18. In der fachsprachlichen Didaktik ist der "fachneutrale" Vorkurs ein Umweg (In Teaching Technical Language, a "Neutral Area" Course is an Evasion)

    Science.gov (United States)

    Becker, Norbert

    1974-01-01

    In learning to read technical language, texts in specialized technical fields are preferable to "neutral area" or popular science texts. Assorted textbooks are suggested, along with suitable types of exercises and their use. Model preparatory exercises and model drills are included. (Text is in German.) (IFS/WGA)

  19. 300 Area D4 Project 2nd Quarter FY06 Building Completion Report

    International Nuclear Information System (INIS)

    Smith, David S.

    2006-01-01

    This report documents the deactivation, decontamination, decommissioning, and demolition of 16 buildings in the 300 Area of the Hanford Site. The D4 of these facilities included characterization, engineering, removal of hazardous and radiologically contaminated materials, equipment removal, utility disconnection, deactivation, decontamination, demolition of the structure, and stabilization or removal of the remaining slab and foundation as appropriate.

  20. Building Cost and Performance Metrics: Data Collection Protocol, Revision 1.0

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, Kimberly M.; Solana, Amy E.; Spees, Kathleen L.

    2005-09-29

    This technical report describes the process for selecting and applying the building cost and performance metrics for measuring sustainably designed buildings in comparison to traditionally designed buildings.

  1. Developing Verification Systems for Building Information Models of Heritage Buildings with Heterogeneous Datasets

    Science.gov (United States)

    Chow, L.; Fai, S.

    2017-08-01

    The digitization and abstraction of existing buildings into building information models requires the translation of heterogeneous datasets that may include CAD, technical reports, historic texts, archival drawings, terrestrial laser scanning, and photogrammetry into model elements. In this paper, we discuss a project undertaken by the Carleton Immersive Media Studio (CIMS) that explored the synthesis of heterogeneous datasets for the development of a building information model (BIM) for one of Canada's most significant heritage assets - the Centre Block of the Parliament Hill National Historic Site. The scope of the project included the development of an as-found model of the century-old, six-story building in anticipation of specific model uses for an extensive rehabilitation program. The as-found Centre Block model was developed in Revit using primarily point cloud data from terrestrial laser scanning. The data was captured by CIMS in partnership with Heritage Conservation Services (HCS), Public Services and Procurement Canada (PSPC), using a Leica C10 and P40 (exterior and large interior spaces) and a Faro Focus (small to mid-sized interior spaces). Secondary sources such as archival drawings, photographs, and technical reports were referenced in cases where point cloud data was not available. As a result of working with heterogeneous data sets, a verification system was introduced in order to communicate to model users/viewers the source of information for each building element within the model.

  2. Spent nuclear fuel canister storage building conceptual design report

    Energy Technology Data Exchange (ETDEWEB)

    Swenson, C.E. [Westinghouse Hanford Co., Richland, WA (United States)

    1996-01-01

    This Conceptual Design Report provides the technical basis for the Spent Nuclear Fuels Project, Canister Storage Building, and as amended by letter (correspondence number 9555700, M.E. Witherspoon to E.B. Sellers, ``Technical Baseline and Updated Cost Estimate for the Canister Storage Building``, dated October 24, 1995), includes the project cost baseline and Criteria to be used as the basis for starting detailed design in fiscal year 1995.

  3. Spent nuclear fuel canister storage building conceptual design report

    International Nuclear Information System (INIS)

    Swenson, C.E.

    1996-01-01

    This Conceptual Design Report provides the technical basis for the Spent Nuclear Fuels Project, Canister Storage Building, and as amended by letter (correspondence number 9555700, M.E. Witherspoon to E.B. Sellers, ''Technical Baseline and Updated Cost Estimate for the Canister Storage Building'', dated October 24, 1995), includes the project cost baseline and Criteria to be used as the basis for starting detailed design in fiscal year 1995

  4. The expert Kurt Reithaar on building safety: 'More and more technical installations for less money'. Fachmann Kurt Reithaar zum Thema Sicherheit bei Gebaeuden: 'Immer mehr Technik fuer weniger Geld'

    Energy Technology Data Exchange (ETDEWEB)

    Reithaar, K [Cerberus AG, Maennedorf (Switzerland); Aeberli, O E

    1990-06-01

    Safety requirements differ largely depending on the kind of building to be protected. In case of industrial buildings the question of data protection is of great importance. In order to comply with this requirement depending on the risk licenses by invitation are used. In industrial buildings also fire protection is to the fore. The weakest factor of safety systems surely is the human factor, i.e. incorrect operation. Therefore sufficient instruction and training of the operators is very important. In order to ensure extensive protection several different technical solutions are necessary. Here microprocessor engineering plays a decisive role. (BWI).

  5. Pollution prevention opportunity assessment for Technical Art

    International Nuclear Information System (INIS)

    Torres, H.M.

    1995-09-01

    This pollution prevention opportunity assessment was conducted to evaluate Technical Art, which is part of the Technical Communications Department at Sandia National Laboratories/California. It is located in Building 912, Room 138. This assessment documents the processes, identifies the hazardous chemical waste streams generated by these processes, and recommends possible ways to minimize waste

  6. Thermal and Economic Analysis of Renovation Strategies for a Historic Building in Mediterranean Area

    Directory of Open Access Journals (Sweden)

    Simona Cirami

    2017-07-01

    Full Text Available Around 30% of the European building stock was built before 1950, when no regulations about energy efficiency were in force. Since only a small part of them has been renovated by now, the energy performance of this building stock is on average quite poor, resulting in a significant impact on the energy balance of European countries, as confirmed by data published by ISTAT (Italian National Statistical Institute. However, energy retrofit in historic edifices is a quite demanding issue as any intervention must take into account the need to preserve existing building materials and appearances while also allowing reversibility and low invasiveness. As an example, in these buildings it is not possible to apply an ETICS (External Thermal Insulation Composite System, since this would alter the historic and architectural value of the façade. On the other hand, internal insulation would have the drawback of reducing the net useful floor area, which also implies a loss of economic value. Moreover, internal insulation may induce overheating risks and mold formation. In this paper, all these issues are investigated with reference to an existing historic building located in southern Italy, showing that a retrofit strategy aimed at energy savings and cost-effectiveness is still possible if suitable materials and solutions are adopted.

  7. Building a new TSO organization and its competences in the Czech Republic

    International Nuclear Information System (INIS)

    Hrehor, Miroslav; Kynčl, Miloš; Mazzini, Guido; Ruščák, Marek; Musa, Alis

    2017-01-01

    This paper contains a proposal for establishing an independent technical and expert nuclear safety team within the National Radiation Protection Institute (SÚRO) in support of the State Office for Nuclear Safety (SÚJB). The team’s competences should be gradual improved so that starting 2021, SÚRO could perform as a fully functional TSO for SÚJB in all key areas of SÚJB’s responsibilities (as far as feasible), covering specifically nuclear safety, technical safety, radiation protection, emergency preparedness and security (physical protection). This objective requires, in addition to personal and material resources, gradual building of expertise as regards existing as well as future nuclear facilities. Preparing a team of TSO workers for future ''professional competences'' is already taking place by addressing research projects focusing on new generation reactors and innovative cooling media. Examples of current activities and applications in these areas are presented.

  8. Technical Report - FINAL

    Energy Technology Data Exchange (ETDEWEB)

    Barbara Luke, Director, UNLV Engineering Geophysics Laboratory

    2007-04-25

    Improve understanding of the earthquake hazard in the Las Vegas Valley and to assess the state of preparedness of the area's population and structures for the next big earthquake. 1. Enhance the seismic monitoring network in the Las Vegas Valley 2. Improve understanding of deep basin structure through active-source seismic refraction and reflection testing 3. Improve understanding of dynamic response of shallow sediments through seismic testing and correlations with lithology 4. Develop credible earthquake scenarios by laboratory and field studies, literature review and analyses 5. Refine ground motion expectations around the Las Vegas Valley through simulations 6. Assess current building standards in light of improved understanding of hazards 7. Perform risk assessment for structures and infrastructures, with emphasis on lifelines and critical structures 8. Encourage and facilitate broad and open technical interchange regarding earthquake safety in southern Nevada and efforts to inform citizens of earthquake hazards and mitigation opportunities

  9. Development of whole-building energy design targets for commercial buildings: Phase 1, Planning: Volume 2, Technical report

    Energy Technology Data Exchange (ETDEWEB)

    Crawley, D.B.; Briggs, R.S.; Jones, J.W.; Seaton, W.W.; Kaufman, J.E.; Deringer, J.J.; Kennett, E.W.

    1987-08-01

    This is the second volume of the Phase 1 report and discusses the 10 tasks performed in Phase 1. The objective of this research is to develop a methodology for setting energy design targets to provide voluntary guidelines for the buildings industry. The whole-building energy targets project is being conducted at the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE) to encourage the construction of energy-efficient buildings by informing designers and owners about cost-effective goals for energy use in new commercial buildings. The outcome of this research will be a flexible methodology for setting such targets. The tasks are listed and discussed in this report as follows: Task 1 - Develop Detailed Project Goals and Objectives; Task 2 - Establish Buildings-Industry Liaison; Task 3 - Develop Approaches to the Energy Targets Model, Building Operations, and Climate; Task 4 - Develop an Approach for Treating Economic Considerations; Task 5 - Develop an Approach for Treating Energy Sources; Task 6 - Collect Energy-Use Data; Task 7 - Survey Energy Expert Opinion; Task 8 - Evaluation Procedure Specification and Integration; Task 9 - Phase 1 Report Development; and Task 10 - Phase 1 Review Planning.

  10. The impact of building orientation and discount rates on a Portuguese reference building refurbishment decision

    International Nuclear Information System (INIS)

    Brandão de Vasconcelos, Ana; Cabaço, António; Pinheiro, Manuel Duarte; Manso, Armando

    2016-01-01

    Refurbishment, as part of the construction industry, has a strong global impact, not only from the viewpoint of economies but also from social and energy-efficiency perspectives. A thermal refurbishment process, in particular, involves numerous decisions and choices; the decision-makers being ultimately confronted with two major questions: which criterion should be adopted in the choice of the refurbishment construction solutions and which refurbishment construction solutions should be chosen? In this paper, a criterion based on technical and economic points of view is proposed, aiming to identify the cost-optimal package of energy efficient solutions from among a set of possible refurbishment measures, within the life cycle of buildings. Sensitivity analyses are also performed so that the results may help the decision-maker choose the appropriate refurbishment solutions to be adopted when different discount rates and building orientations are taken into consideration. A total of seven scenarios, for a macroeconomic perspective, and nine, for a financial perspective, are performed. The costoptimal methodology adopted, following the Directive 2010/31/EU (2010) recommendations, is applied to a Portuguese reference building. The analysis carried out allows obtaining low global life cycle costs solutions and points towards nearly Zero Energy Building (nZEB) concept. The results are important for drawing national political instruments on buildings energy efficiency. - Highlights: •Building refurbishment decision based on technical and economic points of view. •35.000 Packages of thermal rehabilitation solutions considered. •Building orientation and discount rate impact on the cost-optimal package of solutions. •Portuguese reference building case base.

  11. Technology line and case analysis of heat metering and energy efficiency retrofit of existing residential buildings in Northern heating areas of China

    International Nuclear Information System (INIS)

    Zhao Jing; Zhu Neng; Wu Yong

    2009-01-01

    The building area in northern heating areas accounting for 70% of the total land area in China is 6,500,000,000 m 2 . The average heating energy consumption in northern China is 100-200% times more than developed countries in the same latitude. This paper introduced firstly the heat metering and energy efficiency retrofit background of existing residential buildings in northern heating areas of China organized by mohurd and MOF, and then put forward the total principle and contents of retrofit. Through analyzing some retrofit cases in Germany, Poland and China, some technological experiences were summarized and finally a technology line suitable for heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China which involved retrofit for heat metering and temperature regulation of heating systems, heat balance of heat source and network, and building envelope was described to provide a systematic, scientific, technological guide for the retrofit projects of 0.15 billion m 2 in 'the Eleventh Five-Year Plan' period.

  12. Adjustment of Energy requirements in TEK; TEK= Technical Regulations under the Norwegian Planning and Building Act; Justering av energikrav i TEK

    Energy Technology Data Exchange (ETDEWEB)

    Thyholt, Marit; Dokka, Tor Helge; Schild, Peter; Grini, Catherine; Mysen, Mads; Sartori, Igor

    2008-07-01

    The National Office of Building Technology and Administration (BE) desired to review the consequences of different levels of ambition for requirements for heat gaining from vent air, as well as a possible requirement for energy efficient design of building fronts. In addition the energy scope in the regulation (TEK2007) should be adjusted according to the final establishment of a new calculation standard (Norwegian Standard - NS 3031:2007). A statement on these subjects has been carried out at SINTEF Byggforsk, and is described in this report. Adjustments of framework regulations.There are only minor differences between adjusted calculations according to NS 3031 and the original energy framework calculations, i.e. the difference for net energy need amounts to the size of 0 to 6 percent. Heat gain.The report shows that it is possible - both from techical and financial considerations - to increase the requirement level for heat gain from vent air for most categories of buildings. This implies a sharpening of the annual median temperature efficiency from 70 % to 80 %, for all building categories, except from hospitals, institutions and light industry/workshops. A possible sharpening of regulations for heat gain in houses has not been evaluated. Depending on building category a sharpening of regulations for heat gain from vent air will imply that net energy need will be reduced on a scale of 20 to 30 kWh/m2 per annum. The report demonstrates that despite a possible sharpening of the requirements on energy efficiency for heat recovery devices does not prevent the use of large areas of windows and window panes. Vulnerability analyses show that deviations from the prerequisites in the basis for the energy framework concerning air quantities and air temperatures give the possibility of weakening the building's heating characteristics. Building fronts. Different methods for added requirements for building fronts have been examined. The aim has been to find methods and

  13. Technical area status report for low-level mixed waste final waste forms. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Mayberry, J.L.; DeWitt, L.M. [Science Applications International Corp., Idaho Falls, ID (United States); Darnell, R. [EG and G Idaho, Inc., Idaho Falls, ID (United States)] [and others

    1993-08-01

    The Final Waste Forms (FWF) Technical Area Status Report (TASR) Working Group, the Vitrification Working Group (WG), and the Performance Standards Working Group were established as subgroups to the FWF Technical Support Group (TSG). The FWF TASR WG is comprised of technical representatives from most of the major DOE sites, the Nuclear Regulatory Commission (NRC), the EPA Office of Solid Waste, and the EPA`s Risk Reduction Engineering Laboratory (RREL). The primary activity of the FWF TASR Working Group was to investigate and report on the current status of FWFs for LLNM in this TASR. The FWF TASR Working Group determined the current status of the development of various waste forms described above by reviewing selected articles and technical reports, summarizing data, and establishing an initial set of FWF characteristics to be used in evaluating candidate FWFS; these characteristics are summarized in Section 2. After an initial review of available information, the FWF TASR Working Group chose to study the following groups of final waste forms: hydraulic cement, sulfur polymer cement, glass, ceramic, and organic binders. The organic binders included polyethylene, bitumen, vinyl ester styrene, epoxy, and urea formaldehyde. Section 3 provides a description of each final waste form. Based on the literature review, the gaps and deficiencies in information were summarized, and conclusions and recommendations were established. The information and data presented in this TASR are intended to assist the FWF Production and Assessment TSG in evaluating the Technical Task Plans (TTPs) submitted to DOE EM-50, and thus provide DOE with the necessary information for their FWF decision-making process. This FWF TASR will also assist the DOE and the MWIP in establishing the most acceptable final waste forms for the various LLMW streams stored at DOE facilities.

  14. Energy Impact Illinois - Final Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Olson, Daniel [Senior Energy Efficiency Planner; Plagman, Emily [Senior Energy Planner; Silberhorn, Joey-Lin [Energy Efficiency Program Assistant

    2014-02-18

    Energy Impact Illinois (EI2) is an alliance of government organizations, nonprofits, and regional utility companies led by the Chicago Metropolitan Agency for Planning (CMAP) that is dedicated to helping communities in the Chicago metropolitan area become more energy efficient. Originally organized as the Chicago Region Retrofit Ramp-Up (CR3), EI2 became part of the nationwide Better Buildings Neighborhood Program (BBNP) in May 2010 after receiving a $25 million award from the U.S. Department of Energy (DOE) authorized through the American Recovery and Reinvestment Act of 2009 (ARRA). The program’s primary goal was to fund initiatives that mitigate barriers to energy efficiency retrofitting activities across residential, multifamily, and commercial building sectors in the seven-county CMAP region and to help to build a sustainable energy efficiency marketplace. The EI2 Final Technical Report provides a detailed review of the strategies, implementation methods, challenges, lessons learned, and final results of the EI2 program during the initial grant period from 2010-2013. During the program period, EI2 successfully increased direct retrofit activity in the region and was able to make a broader impact on the energy efficiency market in the Chicago region. As the period of performance for the initial grant comes to an end, EI2’s legacy raises the bar for the region in terms of helping homeowners and building owners to take action on the continually complex issue of energy efficiency.

  15. Pusat Tenaga Malaysia's Zero Energy Office (ZEO) Building

    DEFF Research Database (Denmark)

    Tang, C.K.; Reimann, Gregers Peter; Kristensen, Poul Erik

    Technical Review of the Zero Energy Office building in Malaysia. The building, which has an energy index of 50 kWh/m2/year, reaches a net annual energy of zero through the use of building integrated photovoltaic panels. For reference, ordinary offices in Malaysia consume 200 - 300 kWh/m2/year...

  16. Building America FY 2016 Annual Report: Building America Is Driving Real Solutions in the Race to Zero Energy Homes -- Appendix

    Energy Technology Data Exchange (ETDEWEB)

    Sara Farrar, Stacey Rothgeb, Ben Polly, Lieko Earle, Tim Merrigan

    2017-01-01

    This document is a set of appendices presenting technical discussion and references as a companion to the 'Building America FY 2016 Annual Report: Building America Is Driving Real Solutions in the Race to Zero Energy Homes' publication.

  17. Analysis of technical-economic requirements for the construction of a solar power plant on the roof of the business building of the Electrical Engineering Institute 'Nikola Tesla'

    Directory of Open Access Journals (Sweden)

    Grbić Maja

    2014-01-01

    Full Text Available This paper presents an analysis of the technical-economic requirements for the construction of a solar power plant on the roof of the business building of the Electrical Engineering Institute 'Nikola Tesla' in Belgrade. Calculation of solar irradiation is performed and the conceptual design of the disposition of solar panels on the roof of the building is shown as well as their connections to the inverters. Conditions for connecting the plant to the distribution network are checked and an economic analysis of the project is performed.

  18. Technical cooperation on nuclear security between the United States and China : review of the past and opportunities for the future.

    Energy Technology Data Exchange (ETDEWEB)

    Pregenzer, Arian Leigh

    2011-12-01

    The United States and China are committed to cooperation to address the challenges of the next century. Technical cooperation, building on a long tradition of technical exchange between the two countries, can play an important role. This paper focuses on technical cooperation between the United States and China in the areas of nonproliferation, arms control and other nuclear security topics. It reviews cooperation during the 1990s on nonproliferation and arms control under the U.S.-China Arms Control Exchange, discusses examples of ongoing activities under the Peaceful Uses of Technology Agreement to enhance security of nuclear and radiological material, and suggests opportunities for expanding technical cooperation between the defense nuclear laboratories of both countries to address a broader range of nuclear security topics.

  19. Building integrated photovoltaic; Photovaltaique integre aux batiments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-01-01

    Durable, modular and flexible in use, as demonstrated by the different case studies in this publication, photovoltaic can replace diverse building elements, from glass facades to weather proof roofs. This leaflet towards architects describes aesthetic, technical, economic and environmental interest of building integrated photovoltaic. (author)

  20. Optimal choice: assessing the probability of additional damage to buildings caused by water level changes of larger areas

    Science.gov (United States)

    Bijnagte, J. L.; Luger, D.

    2012-12-01

    In the Northern parts of the Netherlands exploration of natural gas reservoirs causes subsidence over large areas. As a consequence, the water levels in canals and polders have to be adjusted over time in order to keep the groundwater levels at a constant depth relative to the surface level. In the middle of the subsidence area it is relatively easy to follow the settlements by a uniform lowering of the water level. This would however result in a relative lowering of the groundwater table at the edges of the subsidence area. Given the presence of soft compressible soils, this would result in induced settlements. For buildings in these areas this will increase the chance of damage. A major design challenge lies therefore in the optimisation of the use of compartments. The more compartments the higher the cost therefore the aim is to make compartments in the water management system that are as large as possible without causing inadmissible damage to buildings. In order to asses expected damage from different use of compartments three tools are needed. The first is a generally accepted method of damage determination, the second a method to determine the contribution to damage of a new influence, e.g. a groundwater table change. Third, and perhaps most importantly, a method is needed to evaluate effects not for single buildings but for larger areas. The first need is covered by established damage criteria like those of Burland & Wroth or Boscardin & Cording. Up until now the second and the third have been problematic. This paper presents a method which enables to assign a contribution to the probability of damage of various recognised mechanisms such as soil and foundation inhomogeneity, uneven loading, ground water level changes. Shallow subsidence due to peat oxidation and deep subsidence due to reservoir depletion can be combined. In order to address the third issue: evaluation of effects for larger areas, the method uses a probabilistic approach. Apart from a

  1. Energy-efficient building - Deficits in higher education; Energieeffizientes Bauen - Defizite in der Hochschulausbildung, Teil 1/3

    Energy Technology Data Exchange (ETDEWEB)

    Lang, T.; Messmer, R. [K.M. Marketing AG, Winterthur (Switzerland); Kunz, M. [Zuercher Hochschule Winterthur, Zentrum Sustainability, Winterthur (Switzerland)

    2005-07-01

    This report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that examined the courses of study offered by Swiss Universities of Applied Science and the Federal Institutes of Technology that are concerned with the use of energy in the building area. The results of the survey are presented and commented on. The authors are of the opinion that basic courses of study fulfil their task of knowledge-transfer in the areas concerning energy, ecology, environment and sustainability, although the educational structures used are complex. The importance of interdisciplinary work is stressed. The focus of knowledge-transfer on persons under 40 years of age is criticised as well as deficits in interdisciplinary teamwork. The authors recommend the setting-up of further education programmes for older architects and professionals in the building technical services area.

  2. Corrective Action Investigation Plan for Corrective Action Unit 406: Area 3 Building 03-74 and Building 03-58 Under ground Discharge Points and Corrective Action Unit 429: Area 3 Building 03-55 and Area 9 Building 09-52 Underground Discharge Points, Tonopah Test Range, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    DOE/NV

    1999-05-20

    This Corrective Action Investigation Plan (CAIP) has been developed in accordance with the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the US Department of Energy, Nevada Operations Office (DOE/NV); the State of Nevada Division of Environmental Protection (NDEP); and the US Department of Defense (FFACO, 1996). The CAIP is a document that provides or references all of the specific information for investigation activities associated with Corrective Action Units (CAUs) or Corrective Action Sites (CASs). According to the FFACO (1996), CASs are sites potentially requiring corrective action(s) and may include solid waste management units or individual disposal or release sites. Corrective Action Units consist of one or more CASs grouped together based on geography, technical similarity, or agency responsibility for the purpose of determining corrective actions. This CAIP contains the environmental sample collection objectives and the criteria for conducting site investigation activities at the Underground Discharge Points (UDPs) included in both CAU 406 and CAU 429. The CAUs are located in Area 3 and Area 9 of the Tonopah Test Range (TTR). The TTR, included in the Nellis Air Force Range, is approximately 255 kilometers (km) (140 miles [mi]) northwest of Las Vegas, Nevada.

  3. The status quo of green-building education in South Africa

    African Journals Online (AJOL)

    2015-10-30

    Oct 30, 2015 ... on projects in the property-development industry. The purpose of this study ... adequate technical understanding of sustainable building methods. ... skills in green building as promptly as role players in the green-building sector might .... The body of knowledge about sustainability and green buildings is ...

  4. Standardization and Green Economic Change - the Case of Energy Efficiency in Buildings

    DEFF Research Database (Denmark)

    Andersen, Maj Munch; Faria, Lourenco

    2015-01-01

    This paper investigates the role of standardization for green economic change using energy efficiency in buildings as a case. Innovation research on standards tends to focus on the competition between competing emerging standards as well as the economic impacts of these. The idea pursued here...... energy efficiency becomes an issue in standardization work using buildings as a case. The paper seeks more specifically to investigate the rise of building related standards generally over time as well as in different technical areas and geographic regions. The hypothesis pursued in this paper...... is that the rise of the green economy can only take place accompanied by considerable institution formation in the form of standards. In this sense, the presence of standards may be seen as an important indicator on the maturity of the greening of the economy. The paper presents early empirical work...

  5. Existing School Buildings: Incremental Seismic Retrofit Opportunities.

    Science.gov (United States)

    Federal Emergency Management Agency, Washington, DC.

    The intent of this document is to provide technical guidance to school district facility managers for linking specific incremental seismic retrofit opportunities to specific maintenance and capital improvement projects. The linkages are based on logical affinities, such as technical fit, location of the work within the building, cost saving…

  6. Estimating rooftop solar technical potential across the US using a combination of GIS-based methods, lidar data, and statistical modeling

    Science.gov (United States)

    Gagnon, Pieter; Margolis, Robert; Melius, Jennifer; Phillips, Caleb; Elmore, Ryan

    2018-02-01

    We provide a detailed estimate of the technical potential of rooftop solar photovoltaic (PV) electricity generation throughout the contiguous United States. This national estimate is based on an analysis of select US cities that combines light detection and ranging (lidar) data with a validated analytical method for determining rooftop PV suitability employing geographic information systems. We use statistical models to extend this analysis to estimate the quantity and characteristics of roofs in areas not covered by lidar data. Finally, we model PV generation for all rooftops to yield technical potential estimates. At the national level, 8.13 billion m2 of suitable roof area could host 1118 GW of PV capacity, generating 1432 TWh of electricity per year. This would equate to 38.6% of the electricity that was sold in the contiguous United States in 2013. This estimate is substantially higher than a previous estimate made by the National Renewable Energy Laboratory. The difference can be attributed to increases in PV module power density, improved estimation of building suitability, higher estimates of total number of buildings, and improvements in PV performance simulation tools that previously tended to underestimate productivity. Also notable, the nationwide percentage of buildings suitable for at least some PV deployment is high—82% for buildings smaller than 5000 ft2 and over 99% for buildings larger than that. In most states, rooftop PV could enable small, mostly residential buildings to offset the majority of average household electricity consumption. Even in some states with a relatively poor solar resource, such as those in the Northeast, the residential sector has the potential to offset around 100% of its total electricity consumption with rooftop PV.

  7. Building technique. Vol. 5. Construction engineering. Pt. 2. Building physics. Bautechnik. Bd. 5. Konstruktiver Ingenieurbau. T. 2. Bauphysik

    Energy Technology Data Exchange (ETDEWEB)

    Cziesielski, E [Technische Univ. Berlin (Germany, F.R.); ed.

    1988-01-01

    This volume on 'Building Technique' gives information on the following subjects: Interaction between building physics and building design (analysis, solutions); thermal protection (heat transfer, thermal protection requirements, energy saving); protection against damp (water economy, water transport, protection against rain); sealing buildings (material, stressing of buildings by humidity of the ground and service water, drainage, sealing); noise insulation (basic terms, sound absorption, acoustic phenomena, noise from domestic equipment, protection against outside noise); fire protection (technical building regulations, fire protection regulations, classes of building material, fire resistance classes, fire behaviour of special building components). The subsequent part of the report is concerned with the history of building design (design and building technique, tasks of the architect, year of birth of modern building design 1743. Prehistory of building design). (HWJ) With 186 figs.

  8. DEVELOPING VERIFICATION SYSTEMS FOR BUILDING INFORMATION MODELS OF HERITAGE BUILDINGS WITH HETEROGENEOUS DATASETS

    Directory of Open Access Journals (Sweden)

    L. Chow

    2017-08-01

    Full Text Available The digitization and abstraction of existing buildings into building information models requires the translation of heterogeneous datasets that may include CAD, technical reports, historic texts, archival drawings, terrestrial laser scanning, and photogrammetry into model elements. In this paper, we discuss a project undertaken by the Carleton Immersive Media Studio (CIMS that explored the synthesis of heterogeneous datasets for the development of a building information model (BIM for one of Canada’s most significant heritage assets – the Centre Block of the Parliament Hill National Historic Site. The scope of the project included the development of an as-found model of the century-old, six-story building in anticipation of specific model uses for an extensive rehabilitation program. The as-found Centre Block model was developed in Revit using primarily point cloud data from terrestrial laser scanning. The data was captured by CIMS in partnership with Heritage Conservation Services (HCS, Public Services and Procurement Canada (PSPC, using a Leica C10 and P40 (exterior and large interior spaces and a Faro Focus (small to mid-sized interior spaces. Secondary sources such as archival drawings, photographs, and technical reports were referenced in cases where point cloud data was not available. As a result of working with heterogeneous data sets, a verification system was introduced in order to communicate to model users/viewers the source of information for each building element within the model.

  9. Final Scientific Technical Report Crowder College MARET Center

    Energy Technology Data Exchange (ETDEWEB)

    Boyt, Art [Crowder College, Neosho, MO (United States); Eberle, Dan [Crowder College, Neosho, MO (United States); Hudson, Pam [Crowder College, Neosho, MO (United States); Hopper, Russ [Crowder College, Neosho, MO (United States)

    2013-06-30

    , exploring and validating new applications of solar and other renewable technologies, the MARET Facility will house a wide variety of programs which will advance implementation of renewable energy throughout the region. These program goals include; Curriculum in renewable energy for pre-engineering transfer programs; Certification and degree programs for technical degrees for Energy Efficiency, Wind, Photovoltaic and Solar Thermal professionals; Short courses and workshops for building management and design professionals; Public education and demonstration projects in renewable energy through conferences and K-12 educational outreach; Technical degree offering in building construction incorporating “best practices” for energy efficiency and renewables; and Business incubators for new renewable energy businesses and new product development The new MARET facility will support the mission of the US Department of Energy (DOE) Solar Program, “to improve America’s security, environmental quality, and economic prosperity through public-private partnerships that bring reliable and affordable solar energy technologies to the marketplace,” through a variety of educational and business assistance programs. Further, technical innovations planned for the MARET facility and its applied research activities will advance the Solar Program strategic goals to “reduce the cost of solar energy to the point it becomes competitive in relevant energy markets (e.g., buildings, power plants) and for solar technology to enable a sustainable solar industry.” Overarching Goals relative to program needs, future expansion, flexibility, quality of materials, and construction and operational costs:; Experimental: The structure and systems of the building operate as an educational resource. The systems are meant to be a source for data collection and study for building users and instructors; Educational: Part of the evolution of this building and its ongoing goals is to use the building as an

  10. Confronting Regulatory Cost and Quality Expectations. An Exploration of Technical Change in Minimum Efficiency Performance Standards

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Margaret [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stanford Univ., CA (United States); Spurlock, C. Anna [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Yang, Hung-Chia [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-09-21

    The dual purpose of this project was to contribute to basic knowledge about the interaction between regulation and innovation and to inform the cost and benefit expectations related to technical change which are embedded in the rulemaking process of an important area of national regulation. The area of regulation focused on here is minimum efficiency performance standards (MEPS) for appliances and other energy-using products. Relevant both to U.S. climate policy and energy policy for buildings, MEPS remove certain product models from the market that do not meet specified efficiency thresholds.

  11. Introduction of building vibration observation data of metropolitan area due to the 2011 off the Pacific coast of Tohoku Earthquake: an Approach of the IT Kyoshin Seismometer for Buildings

    Science.gov (United States)

    Takano, K.; Ito, T.

    2011-12-01

    In the 2011 off the Pacific coast of Tohoku Earthquake, many buildings were vibrated greatly also in the Tokyo metropolitan area where is far left from the hypocenter. We have developed the IT Kyoshin(strong motion) Seismometer for Building which is the observation system of the usual weak earthquake ground motion by installing a lot of acceleration sensors in building, and have been setting it up in some buildings of the University of Tokyo. By this February, we have set up IT Kyoshin Seismometers newly in four buildings of the two remote campus of the University of Tokyo. And we have opend to the public of these observed data. In this building vibration observation system, we can get a lot of building vibration observation data of the Pacific coast of Tohoku Earthquake. We have made the building shaking to visible from the observation data of each building and the appearance of the shake of each building is shown plainly. Moreover, we can see how the vibration property in the usual building is changed by the large shaking. This analysis of the observation data of the building vibration at the earthquake is useful for the detection of the damaged part in the building by the earthquake and for the reinforcement measures in the weak buildings.

  12. Importance of thermal comfort for library building in Kuching, Sarawak

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, S.H.; Baharun, A.; Abdul Mannan, M.D.; Abang Adenan, D.A. [Department of Civil Engineering, Faculty of Engineering, University Malaysia Sarawak (UNIMAS), 94300 Kota Samarahan, Sarawak (Malaysia)

    2013-07-01

    Malaysian Government takes an initiative to provide library in housing areas to improve the quality of human capital. However, the government has to evaluate every aspect of their provision to ensure the services provided meet the demands of the users, including the aspect of thermal comfort in the building. For this study, a library constructed using Industrialised Building System (IBS) are selected for thermal comfort evaluation. The data were analyzed using Corrected Effective Temperature (CET) index. From the data analysis, it shows that thermal comfort in the library could not be achieved most of the time unless when the mechanical cooling is used. A series of technical design improvements are then recommended to improve the thermal comfort inside the library by incorporating construction details without increasing the cost.

  13. ASEAN--USAID Buildings Energy Conservation Project final report. Volume 2, Technology

    Energy Technology Data Exchange (ETDEWEB)

    Levine, M.D.; Busch, J.F. [eds.

    1992-06-01

    This volume reports on research in the area of energy conservation technology applied to commercial buildings in the Association of Southeast Asian Nations (ASEAN) region. Unlike Volume I of this series, this volume is a compilation of original technical papers prepared by different authors in the project. In this regard, this volume is much like a technical journal. The papers that follow report on research conducted by both US and ASEAN researchers. The authors representing Indonesia, Malaysia, Philippines, and Thailand, come from a range of positions in the energy arena, including government energy agencies, electric utilities, and universities. As such, they account for a wide range of perspectives on energy problems and the role that technology can play in solving them. This volume is about using energy more intelligently. In some cases, the effort is towards the use of more advanced technologies, such as low-emittance coatings on window glass, thermal energy storage, or cogeneration. In others, the emphasis is towards reclaiming traditional techniques for rendering energy services, but in new contexts such as lighting office buildings with natural light, or cooling buildings of all types with natural ventilation. Used in its broadest sense, the term ``technology`` encompasses all of the topics addressed in this volume. Along with the more customary associations of technology, such as advanced materials and equipment and the analysis of their performance, this volume treats design concepts and techniques, analysis of ``secondary`` impacts from applying technologies (i.e., unintended impacts, or impacts on parties not directly involved in the purchase and use of the technology), and the collection of primary data used for conducting technical analyses.

  14. Estimation of solar collector area for water heating in buildings of Malaysia

    Science.gov (United States)

    Manoj Kumar, Nallapaneni; Sudhakar, K.; Samykano, M.

    2018-04-01

    Solar thermal energy (STE) utilization for water heating at various sectorial levels became popular and still growing especially for buildings in the residential area. This paper aims to study and identify the solar collector area needed based on the user requirements in an efficient manner. A step by step mathematical approach is followed to estimate the area in Sq. m. Four different cases each having different hot water temperatures (45°, 50°C, 55°C, and 60°C) delivered by the solar water heating system (SWHS) for typical residential application at Kuala Lumpur City, Malaysia is analysed for the share of hot and cold water mix. As the hot water temperature levels increased the share of cold water mix is increased to satisfy the user requirement temperature, i.e. 40°C. It is also observed that as the share of hot water mix is reduced, the collector area can also be reduced. Following this methodology at the installation stage would help both the user and installers in the effective use of the solar resource.

  15. Toward a virtual building laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Klems, J.H.; Finlayson, E.U.; Olsen, T.H.; Banks, D.W.; Pallis, J.M.

    1999-03-01

    In order to achieve in a timely manner the large energy and dollar savings technically possible through improvements in building energy efficiency, it will be necessary to solve the problem of design failure risk. The most economical method of doing this would be to learn to calculate building performance with sufficient detail, accuracy and reliability to avoid design failure. Existing building simulation models (BSM) are a large step in this direction, but are still not capable of this level of modeling. Developments in computational fluid dynamics (CFD) techniques now allow one to construct a road map from present BSM's to a complete building physical model. The most useful first step is a building interior model (BIM) that would allow prediction of local conditions affecting occupant health and comfort. To provide reliable prediction a BIM must incorporate the correct physical boundary conditions on a building interior. Doing so raises a number of specific technical problems and research questions. The solution of these within a context useful for building research and design is not likely to result from other research on CFD, which is directed toward the solution of different types of problems. A six-step plan for incorporating the correct boundary conditions within the context of the model problem of a large atrium has been outlined. A promising strategy for constructing a BIM is the overset grid technique for representing a building space in a CFD calculation. This technique promises to adapt well to building design and allows a step-by-step approach. A state-of-the-art CFD computer code using this technique has been adapted to the problem and can form the departure point for this research.

  16. Research in Technical Colleges

    Science.gov (United States)

    MacLennan, A.

    2008-01-01

    Purpose: The purpose of this paper is to list and demonstrate areas in which research needs to be carried out, or questions answered, in order to raise the quality of technical education. Design/methodology/approach: The area of technical education expanded very rapidly in the late 1950s, and there was little comprehensive knowledge regarding the…

  17. Building a Higher Education Area in Central Asia: challenges and prospects

    Directory of Open Access Journals (Sweden)

    Ann Katherine Isaacs

    2014-12-01

    Full Text Available In recent years, for a variety of reasons, higher education has begun to be considered much more frequently than previously in terms of ‘regions’, or ‘macro-regions’. Although for decades countries sharing some characteristics, or perceived as geographically or culturally closely related to each other, have promoted forms of cooperation between their higher education institutions (with varying degrees of success, it is now widely accepted that to ‘count’ on the world stage, it is useful for single countries, and especially for smaller countries, to work together with a view to making their systems better able to interact and hopefully to promote, increase and make visible their merits. Of course, in higher education as in many other fields, the regions or macro-regions are not defined once and for all, but are the result of stronger or weaker ad hoc groupings which take into account different factors in different contexts. Central Asia is one such potential region: it does not have unquestioned boundaries, but like other macro-regions, and more so than most, it can be understood and constructed in different ways. A current shared understanding of ‘Central Asia’ is that it is formed by the 4 ex-Soviet Republics of Central Asia (Kyrgyzstan, Tajikistan, Turkmenistan and Uzbekistan, plus Kazakhstan. Over the last decade the possibility of building a Higher Education Area in those five republics has been explored, and a large-scale project which uses Tuning methodology to this end is under way. This project, called TuCAHEA (“Towards a Central Asian Higher Education Area: Tuning Structures and Building Quality Culture”, has already elaborated a Central Asian list of Generic Competences and eight Subject Area Groups have formulated their Reference Points and Guidelines. The five Ministries of the five countries have signed a Communiqué indicating their intention to collaborate more closely; a pilot student mobility scheme is soon

  18. Innovative technologies of outsourcing at the machine-building enterprises of Sverdlovsk area

    OpenAIRE

    Petr Krylatkov

    2010-01-01

    The analysis of the basic problems connected with infringements of integrity of the machine-building enterprises of Sverdlovsk area is lead in the article. The specified problems are considered from a position of the complete approach developed by the author. Display of infringements of integrity of some the enterprises are illustrated by data of their inspection. As the effective tool of increase of integrity of the enterprises — expansion use of attitudes of outsourcing is offered. The co...

  19. 300 Area D4 Project 3rd Quarter Fiscal Year 2006 Building Completion Report

    International Nuclear Information System (INIS)

    Smith, D.S.

    2006-01-01

    This report documents the deactivation, decontamination, decommissioning, and demolition of five buildings in the 300 Area of the Hanford Site. The D4 of these facilities included characterization, engineering, removal of hazardous and radiologically contaminated materials, equipment removal, utility disconnection, deactivation, decontamination, demolition of the structure, and stabilization or removal of the remaining slab and foundation as appropriate.

  20. 3D thermal climate monitoring in factory buildings

    NARCIS (Netherlands)

    Posselt, G.; Booij, P.S.; Thiede, S.; Fransman, J.E.; Driessen, B.J.F.; Herrmann, C.

    2015-01-01

    Guaranteeing defined conditions, such as the temperature levels inside the factory's building shell, is often important to produce high-quality products. Heating, ventilation and air conditioning (HVAC) equipment, as part of the technical building services, is energy intensive and accounts for a

  1. Derived concentration guideline levels for Argonne National Laboratory's building 310 area.

    Energy Technology Data Exchange (ETDEWEB)

    Kamboj, S., Dr.; Yu, C ., Dr. (Environmental Science Division)

    2011-08-12

    The derived concentration guideline level (DCGL) is the allowable residual radionuclide concentration that can remain in soil after remediation of the site without radiological restrictions on the use of the site. It is sometimes called the single radionuclide soil guideline or the soil cleanup criteria. This report documents the methodology, scenarios, and parameters used in the analysis to support establishing radionuclide DCGLs for Argonne National Laboratory's Building 310 area.

  2. INDEPENDENT TECHNICAL REVIEW OF THE BUILDING 100 PLUME, FORMER DOE PINELLAS SITE (YOUNG - RAINEY STAR CENTER), LARGO, FLORIDA

    Energy Technology Data Exchange (ETDEWEB)

    Eddy-Dilek, C.; Rossabi, J.; Amidon, M.; Riha, B.; Kaback, D.

    2010-07-30

    Contaminated groundwater associated with Building 100 at the Young-Rainey Science, Technology, and Research Center, formerly the DOE Pinellas plant, is the primary remedial challenge that remains to be addressed at the site. Currently, Building 100 is an active industrial facility that is now owned and operated by the Pinellas county government. Groundwater samples collected from monitoring wells recently installed near the southern boundary of the site suggest that contaminated groundwater has migrated off the plant site. In response to the challenges presented by the Building 100 plume, the Office of Legacy Management (LM) requested assistance from the DOE Office of Groundwater and Soil Remediation (EM-32) to provide a review team to make technical recommendations so that they can efficiently and effectively address characterization and remediation of the plume. The review team was unanimous in the conclusion that a dynamic strategy that combines a phased implementation of direct push samplers, sensors, and tools can be used to better delineate the extent of contamination, control plume migration, and rapidly remediate the contaminated groundwater at the site. The initial efforts of the team focused on reviewing the site history and data, organizing the information into a conceptual model, identifying appropriate technologies, and recommending an integrated strategy. The current groundwater data from the site indicate a two-lobed plume extending to the east and south. To the east vinyl chloride is the primary contaminant of concern, to the south, vinyl chloride and cis1, 2-DCE are the primary contaminants. The limited data that are available suggest that reductive dechlorination of the TCE is already occurring but is not sufficient to prevent offsite migration of low concentrations of TCE daughter products. The team recommends that DOE pursue a strategy that builds on the natural cleansing capacity of the subsurface with reductive methods including biostimulation

  3. Energy efficiency in buildings. Yearbook 2013; Energieeffizienz in Gebaeuden. Jahrbuch 2013

    Energy Technology Data Exchange (ETDEWEB)

    Poeschk, Juergen (ed.)

    2013-06-01

    The book under consideration presents current political controversies and technical solutions. Numerous practical examples show in detail how the German building stock for energy transition can be made fit. 40 technical papers shed light on the following topics: policy strategies, efficiency concepts on the test stand, districts and quarters, positive results: The house as an energy source, energy storage facilities for buildings, and smart energy.

  4. Record of Technical Change No.2 for ''Corrective Action Investigation Plan for Corrective Action Unit 143: Area 25 Contaminated Waste Dumps, Nevada Test Site, Nevada''

    International Nuclear Information System (INIS)

    1999-01-01

    This Record of Technical Change provides updates to the technical information included in ''Corrective Action Investigation Plan for Corrective Action Unit 143: Area 25 Contaminated Waste Dumps, Nevada Test Site, Nevada.''

  5. Energy retrofit of an office building by substitution of the generation system: performance evaluation via dynamic simulation versus current technical standards

    International Nuclear Information System (INIS)

    Testi, D; Schito, E; Grassi, W; Menchetti, E

    2014-01-01

    Constructions built in Italy before 1945 (about 30% of the total built stock) feature low energy efficiency. Retrofit actions in this field can lead to valuable energetic and economic savings. In this work, we ran a dynamic simulation of a historical building of the University of Pisa during the heating season. We firstly evaluated the energy requirements of the building and the performance of the existing natural gas boiler, validated with past billings of natural gas. We also verified the energetic savings obtainable by the substitution of the boiler with an air-to-water electrically-driven modulating heat pump, simulated through a cycle-based model, evaluating the main economic metrics. The cycle-based model of the heat pump, validated with manufacturers' data available only at specified temperature and load conditions, can provide more accurate results than the simplified models adopted by current technical standards, thus increasing the effectiveness of energy audits

  6. An Evaluation of the Employee Training and Development Process for Nicolet Area Technical College's Basic Education Program.

    Science.gov (United States)

    Karl, Luis C.

    The adult basic education (ABE) program at Nicolet Area Technical College (NATC) evaluated its training and development (T&D) process for new basic education instructors. The study gathered monitoring and screening criteria that addressed valuable components for use in an instrument for validating effectiveness of the ABE program (T&D)…

  7. Capacity building in nuclear science and technology through the IAEA fellowship and scientific visit programme for Malaysia

    International Nuclear Information System (INIS)

    Saliza Jam; Ainul Hayati Daud

    2005-01-01

    Malaysia participates actively in the IAEA Technical Co-operation Programme (TCP) since it becomes a member to IAEA in 1969. The primary objective of the programme is to assist member states in achieving self-reliance in nuclear science and technology by strengthening human resource and the institutions. Human resource development has always been considered to be the most important sector cross-cutting all national programme areas. One of the technical assistance offers under the IAEA Technical Co-operation Programme (TCP) is the fellowship and scientific visits programme. This report analyses the development of capacity building in Malaysia through the IAEA fellowship and scientific visit programme during the period of 2003-2005. It also describes the success and challenges encountered during the implementation of the programme. (Author)

  8. 200-UP-2 Operable Unit technical baseline report

    International Nuclear Information System (INIS)

    Deford, D.H.

    1991-02-01

    This report is prepared in support of the development of a Remedial Investigation/Feasibility Study (RI/FS) Work Plan for the 200-UP-2 Operable Unit by EBASCO Environmental, Incorporated. It provides a technical baseline of the 200-UP-2 Operable Unit and results from an environmental investigation undertaken by the Technical Baseline Section of the Environmental Engineering Group, Westinghouse Hanford Company (Westinghouse Hanford). The 200-UP-2 Operable Unit Technical Baseline Report is based on review and evaluation of numerous Hanford Site current and historical reports, Hanford Site drawings and photographs and is supplemented with Hanford Site inspections and employee interviews. No field investigations or sampling were conducted. Each waste site in the 200-UP-2 Operable Unit is described separately. Close relationships between waste units, such as overflow from one to another, are also discussed. The 200-UP-2 Operable Unit consists of liquid-waste disposal sites in the vicinity of, and related to, U Plant operations in the 200 West Area of the Hanford Site. The ''U Plant'' refers to the 221-U Process Canyon Building, a chemical separations facility constructed during World War 2. It also includes the Uranium Oxide (UO 3 ) Plant, which was constructed at the same time and, like the 221-U Process Canyon Building, was later converted for other missions. Waste sites in the 200-UP-2 Operable Unit are associated with the U Plant Uranium Metal Recovery Program mission that occurred between 1952 and 1958 and the UO 3 Plant's ongoing uranium oxide mission and include one or more cribs, reverse wells, french drains, septic tanks and drain fields, trenches, catch tanks, settling tanks, diversion boxes, waste vaults, and the lines and encasements that connect them. 11 refs., 1 tab

  9. Handbook of Technical Communication

    OpenAIRE

    Mehler , Alexander; Romary , Laurent; Gibbon , Dafydd

    2012-01-01

    International audience; The handbook "Technical Communication" brings together a variety of topics which range from the role of technical media in human communication to the linguistic, multimodal enhancement of present-day technologies. It covers the area of computer-mediated text, voice and multimedia communication as well as of technical documentation. In doing so, the handbook takes professional and private communication into account. Special emphasis is put on technical communication bas...

  10. Courthouse Prototype Building

    Energy Technology Data Exchange (ETDEWEB)

    Malhotra, Mini [ORNL; New, Joshua Ryan [ORNL; Im, Piljae [ORNL

    2018-02-01

    As part of DOE's support of ANSI/ASHRAE/IES Standard 90.1 and IECC, researchers at Pacific Northwest National Laboratory (PNNL) apply a suite of prototype buildings covering 80% of the commercial building floor area in the U.S. for new construction. Efforts have started on expanding the prototype building suite to cover 90% of the commercial building floor area in the U.S., by developing prototype models for additional building types including place of worship, public order and safety, public assembly. Courthouse is courthouse is a sub-category under the “Public Order and Safety" building type category; other sub-categories include police station, fire station, and jail, reformatory or penitentiary.ORNL used building design guides, databases, and documented courthouse projects, supplemented by personal communication with courthouse facility planning and design experts, to systematically conduct research on the courthouse building and system characteristics. This report documents the research conducted for the courthouse building type and proposes building and system characteristics for developing a prototype building energy model to be included in the Commercial Building Prototype Model suite. According to the 2012 CBECS, courthouses occupy a total of 436 million sqft of floor space or 0.5% of the total floor space in all commercial buildings in the US, next to fast food (0.35%), grocery store or food market (0.88%), and restaurant or cafeteria (1.2%) building types currently included in the Commercial Prototype Building Model suite. Considering aggregated average, courthouse falls among the larger with a mean floor area of 69,400 sqft smaller fuel consumption intensity building types and an average of 94.7 kBtu/sqft compared to 77.8 kBtu/sqft for office and 80 kBtu/sqft for all commercial buildings.Courthouses range in size from 1000 sqft to over a million square foot building gross square feet and 1 courtroom to over 100 courtrooms. Small courthouses

  11. Indoor Radon Concentration Related to Different Radon Areas and Indoor Radon Prediction

    Science.gov (United States)

    Juhásová Šenitková, Ingrid; Šál, Jiří

    2017-12-01

    Indoor radon has been observed in the buildings at areas with different radon risk potential. Preventive measures are based on control of main potential radon sources (soil gas, building material and supplied water) to avoid building of new houses above recommended indoor radon level 200 Bq/m3. Radon risk (index) estimation of individual building site bedrock in case of new house siting and building protection according technical building code are obligatory. Remedial actions in buildings built at high radon risk areas were carried out principally by unforced ventilation and anti-radon insulation. Significant differences were found in the level of radon concentration between rooms where radon reduction techniques were designed and those where it was not designed. The mathematical model based on radon exhalation from soil has been developed to describe the physical processes determining indoor radon concentration. The model is focused on combined radon diffusion through the slab and advection through the gap from sub-slab soil. In this model, radon emanated from building materials is considered not having a significant contribution to indoor radon concentration. Dimensional analysis and Gauss-Newton nonlinear least squares parametric regression were used to simplify the problem, identify essential input variables and find parameter values. The presented verification case study is introduced for real buildings with respect to various underground construction types. Presented paper gives picture of possible mathematical approach to indoor radon concentration prediction.

  12. Technical and economic feasibility of thermal storage. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Shelpuk, B.; Joy, P.; Crouthamel, M.

    1977-06-01

    The technical and economic feasibility of various thermal energy storage alternatives is determined by comparing the system performance and annualized cost which result from each storage alternative operating with the same solar collector model, the same building load model, and the same heating system and controls model. Performance and cost calculations are made on the basis of an hour-by-hour time step using actual weather bureau data for Albuquerque, N. M., and New York City for a single six-month heating season. The primary approach to comparing various storage alternatives is to allow the collector area and storage mass to vary until a minimum cost combination is achieved. In the Albuquerque location collector area of 325 ft/sup 2/, water storage mass of 12.5 lb/ft/sup 2/ of collector area, and phase change mass of 6.25 lb/ft/sup 2/ of collector area results in minimum cost systems, each of which delivers about 50% of the total building demand. The primary conclusion is that, using current costs for materials and containers, water is the cheapest storage alternative for heating applications in both Albuquerque and New York City. The cost of containing or encapsulating phase change materials, coupled with their small system performance advantage, is the main reason for this conclusion. The use of desiccant materials for thermal storage is considered to be impractical due to irreversibilities in thermal cycling.

  13. The Trade Fair: Introducing ESP Multimedia at a Technical University in Taiwan

    Directory of Open Access Journals (Sweden)

    Shu-Chiao Tsai

    2008-09-01

    Full Text Available This discussion provides an overview of steps in developing and assessing ESP multimedia courseware at a technical university in Taiwan. The courseware is designed to expand language skills that foster Chinese learners of English as they develop communicative skills for international business. Student evaluations of the prototype for its Trade Fair component suggests that it is useful for situating the learning process and simulating social cues, which in turn supports building the communicative skills needed for the kinds of interaction demanded by tourism, travel, hospitality, and similar areas of international business.

  14. Fifty years of Technical Cooperation

    International Nuclear Information System (INIS)

    2007-01-01

    The International Atomic Energy Agency (IAEA) was established in Vienna in 1957. The Statute of the IAEA, approved by 81 nations, founded the organization on three pillars: nuclear verification; safety and security; and the transfer of technology. Today, these three pillars still remain at the heart of the organization's work. However, the way in which the IAEA carries out this work, particularly with regard to technology transfer, has changed greatly over the years. When the IAEA opened for business, nuclear science and technology were in their infancy. Many Member States had no nuclear capacity at all. The IAEA's 'technical assistance' programme, as it was then known, was modest. Early projects were small in scale and short lived, focusing mainly on building human capacities and creating institutions and facilities that would support the introduction of nuclear technology in a safe and effective manner. Today, the picture is more complex. Instead of merely offering assistance, the IAEA focuses on cooperation for sustainable socioeconomic development, building on the skills and infrastructure that Member States have acquired over the past five decades. Member States are full partners in the process, guiding the IAEA's technical cooperation activities, setting national and regional priorities, and offering training opportunities and technical support to the IAEA and to other Member States. Technical cooperation between developing countries is facilitated and supported through regional cooperative agreements. Regional centres of expertise play an important role in sharing the benefits of nuclear science and technology among Member States

  15. 4th July 2011 - Russian Deputy Director-General Director of Directorate for Scientific and Technical Complex ROSATOM V. Pershukov in the ATLAS underground experimental area with Adviser T. Kurtyka, ATLAS Technical Coordinator M. Nessi and ATLAS Russian users.

    CERN Multimedia

    Maximilien Brice

    2011-01-01

    4th July 2011 - Russian Deputy Director-General Director of Directorate for Scientific and Technical Complex ROSATOM V. Pershukov in the ATLAS underground experimental area with Adviser T. Kurtyka, ATLAS Technical Coordinator M. Nessi and ATLAS Russian users.

  16. Sampling and analysis plan for assessment of beryllium in soils surrounding TA-40 building 15

    Energy Technology Data Exchange (ETDEWEB)

    Ruedig, Elizabeth [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-12-19

    Technical Area (TA) 40 Building 15 (40-15) is an active firing site at Los Alamos National Laboratory. The weapons facility operations (WFO) group plans to build an enclosure over the site in 2017, so that test shots may be conducted year-round. The enclosure project is described in PRID 16P-0209. 40-15 is listed on LANL OSH-ISH’s beryllium inventory, which reflects the potential for beryllium in/on soils and building surfaces at 40-15. Some areas in and around 40-15 have previously been sampled for beryllium, but past sampling efforts did not achieve complete spatial coverage of the area. This Sampling and Analysis Plan (SAP) investigates the area surrounding 40-15 via 9 deep (≥1-ft.) soil samples and 11 shallow (6-in.) soil samples. These samples will fill the spatial data gaps for beryllium at 40-15, and will be used to support OSH-ISH’s final determination of 40-15’s beryllium registry status. This SAP has been prepared by the Environmental Health Physics program in consultation with the Industrial Hygiene program. Industrial Hygiene is the owner of LANL’s beryllium program, and will make a final determination with regard to the regulatory status of beryllium at 40-15.

  17. The Evaluation of Facilitation Process in Building Community Capacity about OVOP Concept in Kenjeran Coastal Area, Surabaya

    Science.gov (United States)

    Handayeni, K. D. M. E.; Santoso, E. B.; Siswanto, V. K.

    2017-07-01

    The concept of One Village One Product (OVOP) is an approach to the development potential of the area in the region to produce products that can compete in the global market, while still having unique characteristics of the area. Bulak District is one of the Kenjeran coastal area in Surabaya, Indonesia. Bulak District has had a great potential of marine products, but still contribute greatly in improving the people's welfare. Total activities of SMEs in the District of Bulak quite a lot, but the resulting product unknown to the wider community and the global marketplace. Activity of facilitation for SMEs society do to build community capacity in the implementation of the concept of OVOP. Based on the results of the evaluation assistance through Wilcoxon Signed Ranks Test result an increased understanding of the community regarding to the five subjects related OVOP concept. There are six factors to note in mentoring activities that need to be considered for the sustainability of community capacity building programs on OVOP.

  18. Building, Maintaining, and Ending Relationships: An Urban School District and a Technical Assistance Team. Documentation and Technical Assistance in Urban Schools.

    Science.gov (United States)

    Holmes, Manford L.

    This paper describes the nature of the relationships developed between the technical assistance team of the Documentation and Technical Assistance (DTA) Project and members of a Chicago (Illinois) school district staff with whom the DTA worked. First, the methodology with which the technical assistance work was studied is described, as is the…

  19. 300 Area D4 Project 4th Quarter Fiscal Year 2006 Building Completion Report

    International Nuclear Information System (INIS)

    D. S. Smith

    2007-01-01

    This report documents the deactivation, decontamination, decommissioning, and demolition (D4) of nine buildings in the 300 Area of the Hanford Site. The D4 of these facilities included characterization, engineering, removal of hazardous and radiologically contaminated materials, equipment removal, utility disconnection, deactivation, decontamination, demolition of the structure, and stabilization or removal of the remaining slab and foundation, as appropriate

  20. VARIANT FOR CONSTRUCTION, REPAIR OR RECONSTRUCTION OF BUILDING

    Directory of Open Access Journals (Sweden)

    S. N. Osipov

    2016-01-01

    Full Text Available In the XXI century moral depreciation concept comprises not only deterioration of outside appearance of construction elements in the course of time but accelerated fashion changes in respect of interior design and rapid increase in technical level for residence buildings. For this reason if average rate of building dilapidation in the buildings of series 1–335, 1–335А and 1–464А constructed in Minsk within the period of 1957–1975 and being operated till 2005–2006 has constituted 25–29 % and their moral depreciation has been equal to more than 40 % then rate of the moral depreciation has significantly increased in the XXI century. Such situation requires execution of special investigations. High operating rates of refinancing have led to the necessity for record keeping of initial expenses and repairability levels because selection of building construction, repair or reconstruction variant depends on these parameters. Repairability classification of main elements of residence buildings and premises has been proposed for regulation of such selection procedure. In this case it is recommended to take into account technological effectiveness of repair and technical service, verifiability, accessibility, easy dismountability, substitutability and interchangeability of construction elements and technical devices. The paper presents nomograms that permit to make easier practical calculations on determination of cost-efficient time period for operation of the element prior to its substitution at various refinancing rates and also for comparison of relative initial expenses according to time service. 

  1. Seven thematic sheets 'solar and building' to understand the stakes of solar for the building industry

    International Nuclear Information System (INIS)

    2016-01-01

    In order to highlight the interest of solar energy for building for commissioning clients and public authorities, in terms of quality and competitiveness, this document proposes seven sheets which respectively address: the positive energy building, the development of solar energy in buildings with local authorities, photovoltaic self-consumption, the competitiveness of solar PV, an offer of quality by professionals of the solar PV, the competitiveness of solar heating. Each sheet proposes an overview of stakes, technical solutions, and local or professional commitment, and formulates some proposals for the future

  2. Impact of Fire Ventilation on General Ventilation in the Building

    Science.gov (United States)

    Zender-Świercz, Ewa; Telejko, Marek

    2017-10-01

    The fire of building is a threat to its users. The biggest threat is generation, during lifetime of fire, hot gases and smoke. The purpose of quick and efficient evacuation from the area covered by the fire, at first step the escape routes have to be secured from smokiness. The smoke ventilation systems are used for this purpose. The proper design and execution of smoke ventilation is important not only because of the safety, but also of the maintenance of comfort in the building at a time when there is no fire. The manuscript presents the effect of incorrectly realized smoke ventilation in the stairwell of the medium building. The analysis shows that the flaps of smoke ventilation located in the stairwell may have a significant impact on the proper functioning of mechanical ventilation in the period when there is no fire. The improperly installed or incorrect insulated components cause perturbation of air flow and they change pressure distribution in the building. The conclusion of the analysis is the need to include the entire technical equipment of the building during the design and realization of its individual elements. The impact of various installations at each other is very important, and the omission of any of them can cause disturbances in the proper work of another.

  3. Technical Safety Requirements for the Waste Storage Facilities

    International Nuclear Information System (INIS)

    Laycak, D.T.

    2010-01-01

    This document contains Technical Safety Requirements (TSR) for the Radioactive and Hazardous Waste Management (RHWM) WASTE STORAGE FACILITIES, which include Area 625 (A625) and the Decontamination and Waste Treatment Facility (DWTF) Storage Area at Lawrence Livermore National Laboratory (LLNL). The TSRs constitute requirements regarding the safe operation of the WASTE STORAGE FACILITIES. These TSRs are derived from the Documented Safety Analysis for the Waste Storage Facilities (DSA) (LLNL 2009). The analysis presented therein determined that the WASTE STORAGE FACILITIES are low-chemical hazard, Hazard Category 2 non-reactor nuclear facilities. The TSRs consist primarily of inventory limits and controls to preserve the underlying assumptions in the hazard and accident analyses. Further, appropriate commitments to safety programs are presented in the administrative controls sections of the TSRs. The WASTE STORAGE FACILITIES are used by RHWM to handle and store hazardous waste, TRANSURANIC (TRU) WASTE, LOW-LEVEL WASTE (LLW), mixed waste, California combined waste, nonhazardous industrial waste, and conditionally accepted waste generated at LLNL as well as small amounts from other U.S. Department of Energy (DOE) facilities, as described in the DSA. In addition, several minor treatments (e.g., size reduction and decontamination) are carried out in these facilities. The WASTE STORAGE FACILITIES are located in two portions of the LLNL main site. A625 is located in the southeast quadrant of LLNL. The A625 fenceline is approximately 225 m west of Greenville Road. The DWTF Storage Area, which includes Building 693 (B693), Building 696 Radioactive Waste Storage Area (B696R), and associated yard areas and storage areas within the yard, is located in the northeast quadrant of LLNL in the DWTF complex. The DWTF Storage Area fenceline is approximately 90 m west of Greenville Road. A625 and the DWTF Storage Area are subdivided into various facilities and storage areas, consisting

  4. Technical Safety Requirements for the Waste Storage Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Laycak, D T

    2008-06-16

    This document contains Technical Safety Requirements (TSR) for the Radioactive and Hazardous Waste Management (RHWM) WASTE STORAGE FACILITIES, which include Area 625 (A625) and the Decontamination and Waste Treatment Facility (DWTF) Storage Area at Lawrence Livermore National Laboratory (LLNL). The TSRs constitute requirements regarding the safe operation of the WASTE STORAGE FACILITIES. These TSRs are derived from the 'Documented Safety Analysis for the Waste Storage Facilities' (DSA) (LLNL 2008). The analysis presented therein determined that the WASTE STORAGE FACILITIES are low-chemical hazard, Hazard Category 2 non-reactor nuclear facilities. The TSRs consist primarily of inventory limits and controls to preserve the underlying assumptions in the hazard and accident analyses. Further, appropriate commitments to safety programs are presented in the administrative controls sections of the TSRs. The WASTE STORAGE FACILITIES are used by RHWM to handle and store hazardous waste, TRANSURANIC (TRU) WASTE, LOW-LEVEL WASTE (LLW), mixed waste, California combined waste, nonhazardous industrial waste, and conditionally accepted waste generated at LLNL as well as small amounts from other U.S. Department of Energy (DOE) facilities, as described in the DSA. In addition, several minor treatments (e.g., size reduction and decontamination) are carried out in these facilities. The WASTE STORAGE FACILITIES are located in two portions of the LLNL main site. A625 is located in the southeast quadrant of LLNL. The A625 fenceline is approximately 225 m west of Greenville Road. The DWTF Storage Area, which includes Building 693 (B693), Building 696 Radioactive Waste Storage Area (B696R), and associated yard areas and storage areas within the yard, is located in the northeast quadrant of LLNL in the DWTF complex. The DWTF Storage Area fenceline is approximately 90 m west of Greenville Road. A625 and the DWTF Storage Area are subdivided into various facilities and storage areas

  5. Training on radiation protection in university area. Experience of Technical University of Catalonia

    International Nuclear Information System (INIS)

    Ortega, X.

    2007-01-01

    This paper presents an overview of the different agents that are involved in training on Radiation Protection in Spain. The main circumstances which can introduce new challenges in radiation protection practices are reviewed, namely the planned modifications in the regulation framework, the mobility of European workers, the consequences of deregulation of the electric system, the moratorium of the Spanish nuclear programme and the changes in Spanish studies resulting from implementation of the European Higher Education Area. In relation to the contributions that university groups can develop in this field, the author makes some suggestions according to his own experience in the Technical University of Catalonia. It is emphasized that this contribution must be characterized by its quality, credibility and independence. It should include activities such as development of R and D studies, the implementation of accredited laboratories, organization of post-graduate courses, preparation of teaching materials and technical publications, and collaboration with public institutions, scientific and professional societies and other organizations. Finally, the other new activity that is stressed is related to the efforts required to improve information and communication to the stake holders and a growing social interest. (Author)

  6. The high-rise building. A review of sociological approaches for study

    Directory of Open Access Journals (Sweden)

    Jorge Vergara Vidal

    2017-12-01

    Full Text Available The verticalization of Chilean cities is a phenomenon that attracts the public interest and requires an understanding that exceeds the economic reasons and technical possibilities that lead to the proliferation of high buildings within them. This paper reviews in the sociological literature the treatment given to high-rise buildings with the aim of providing clues that collaborate with the social study of these architectural forms. The conclusions identify an epistemological turn that has allowed tools to link the architectural, material and technical aspects involved in high-rise buildings with the sociological analysis of these.

  7. Building Materials, Ionizing Radiation and HBIM: A Case Study from Pompei (Italy

    Directory of Open Access Journals (Sweden)

    Pasquale Argenziano

    2018-01-01

    Full Text Available This paper presents a different point of view on the conservation of the built heritage, adding ionizing radiation to the most well-known digital documentation dataset. Igneous building materials characterize most of the built heritage in the Campania region, and in a large part of southern Italy. The ionizing radiations proceeding from these materials can produce stochastic biological effects on the exposed living beings. The research team designed and tested a technical-scientific protocol to survey and analyse this natural phenomenon in association with the use of geological material for building purposes. Geographical Information Systems (GISs, City Information Modelling (CIM, and Building Information Modelling (BIM are the digital tools used to manage the construction entities and their characteristics, and then to represent the thematic data as false-colour images. The emission spectra of fair-faced or plastered materials as a fingerprint of their nature is proposed as a non-invasive method. Due to both the huge presence of historical buildings and an intense touristic flow, the main square of Pompei has been selected as a study area.

  8. Training program for energy conservation in new-building construction. Volume II. Energy conservation technology: for the building inspector

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-12-01

    A Model Code for Energy Conservation in New Building Construction has been developed by those national organizations primarily concerned with the development and promulgation of model codes. The technical provisions are based on ASHRAE Standard 90-75 and are intended for use by state and local officials. This training manual contains the basic information necessary to acquaint the field building inspector with the concepts of energy conservation in buildings and instructs him in the basic techniques of field inspection of energy compliance.

  9. Energy policy instruments and technical change in the residential building sector

    NARCIS (Netherlands)

    Beerepoot, W.M.C.

    2007-01-01

    The passing by the European Parliament of the Energy Performance of Buildings Directive (EPBD) in 2003 obliges all European member states to implement energy regulations for buildings based on the concept of energy performance by the year 2009 ultimately. Given the importance of the development of

  10. Role of cooperation activities for capacity building of Romanian Regulatory Authority (CNCAN)

    International Nuclear Information System (INIS)

    Biro, L.; Ciurea-Ercau, C.

    2010-01-01

    With a slow but active nuclear development program of sector since 1980, Romanian regulatory authority had to permanently adapt to the changes in national and international environment in order ensure continuously increase of capacity building and effectiveness, commensurate with the growing nuclear sector. Limited human resources available at the national level put the Romanian Regulatory Authority in the position of building the Technical Support Organization as part of its on organization. International cooperation played an important role in capacity building of Romanian regulatory body and providing necessary assistance in performing regulatory activities or support in development of regulatory framework. Fellowships and technical visits, workshops and training courses provided through IAEA TC at national or regional level, technical assistance provided by European Commission (EC) through PHARE Projects, all provided valuable contribution in assuring training of regulatory staff and development of proper regulatory framework in Romania. Therefore, Romanian Regulatory Authority is putting a strong accent on strengthening and promoting international cooperation through IAEA Technical Cooperation Programme, Molls between regulatory bodies, as one of the key elements in supporting capacity building of regulatory authorities in countries having small or embarking on nuclear power program. Building networks between training centers and research facilities and establishments of regional training centers represent one of the future viable options in preserving knowledge in nuclear field. (author)

  11. Assessment of technical and economical viability for large-scale conversion of single family residential buildings into zero energy buildings in Brazil: Climatic and cultural considerations

    International Nuclear Information System (INIS)

    Pacheco, Miguel; Lamberts, Roberto

    2013-01-01

    This paper addresses the viability of converting single-family residential buildings in Brazil into zero energy buildings (ZEBs). The European Union and the United States aim ZEBs implementation to address ‘peak oil’ and environmental concerns. However, literature shows no agreement on a consensual definition of ZEB. Seeking a Brazilian ZEB definition, this paper addresses PassivHaus and thermal comfort standards for hot climates, source metrics for ZEB, Brazil′s energy mix, residential energy end uses and Brazilian legal framework for residential photovoltaic (PV) generation. Internal Rate of Return for PV systems in two Brazilian cities is calculated under various scenarios. It shows grid parity was reached from April 2012 to November 2012 assuming residential electric tariffs of that period and the financial conditions given by the Brazilian government for the construction of new dams in the Amazon and the lowest rates offered by Brazilian banks to private individuals. Governmental decision to lower electric residential tariffs in November 2012 reduced the scope of grid parity. Later revocation of a tax exemption in April 2013 ended grid parity in Brazil. It concludes, conversely to developed countries, it is the volatile Brazilian energy policy, instead of economical barriers, the main obstacle for ZEB viability in Brazil. - Highlights: • Critique on super insolated buildings as a good solution for hot climates. • PV parity already reached in some parts of Brazil. • Proposal for a zero energy building definition for Brazil. • Critique of the source metric for energy balance in zero energy buildings. • Average roof area in Brazil enough for PV array to meet average energy consumption

  12. Preliminary data from an instantaneous profile test conducted near the Mixed Waste Landfill, Technical Area 3, Sandia National Laboratories/New Mexico

    International Nuclear Information System (INIS)

    Bayliss, S.C.; Goering, T.J.; McVey, M.D.; Strong, W.R.; Peace, J.L.

    1996-04-01

    This paper presents data from an instantaneous profile test conducted near the Sandia National Laboratories/New Mexico Mixed Waste Landfill in Technical Area 3. The test was performed from December 1993 through 1995 as part of the environmental Restoration Project's Phase 2 RCRA Facility Investigation of the Mixed Waste Landfill. The purpose of the test was to measure the unsaturated hydraulic properties of soils near the Mixed Waste Landfill. The instantaneous profile test and instrumentation are described, and the pressure and moisture content data from the test are presented. These data may be useful for understanding the unsaturated hydraulic properties of soils in Technical Area 3 and for model validation, verification, and calibration

  13. Indicators for functional service life of building structures

    NARCIS (Netherlands)

    Blok, R.; Teuffel, P.

    2014-01-01

    The Estimated Service Life, ESL, is of a major influence in many building assessments. The comparison and optimization of design alternatives depend on the accuracy of this ESL. More and more the Functional Service Life rather than the Technical Service Life is decisive in how long a building can be

  14. Technical Writing Tips

    Science.gov (United States)

    Kennedy, Patrick M.

    2004-01-01

    The main reason engineers, technicians, and programmers write poor technical documents is because they have had little training or experience in that area. This article addresses some of the basics that students can use to master technical writing tasks. The article covers the most common problems writers make and offers suggestions for improving…

  15. TECHNICAL AND PEDAGOGICAL SERVICE QUALITY OF E-LEARNING: a research framework for the development of a systematic means of identification and adaptation testing

    Directory of Open Access Journals (Sweden)

    Chaminda Chiran Jayasundara

    2009-11-01

    Full Text Available This paper discusses a research framework that can be applied to develop and measure technical and pedagogical service quality of e-leaning in Sri Lankan phenomenon. This study is an in-depth empirical investigation which seeks to build up an instrument to predict technical and pedagogical service quality of e-learning in Sri Lanka. The specific objectives are to investigate what comprises technical and pedagogical service quality of e-learning: to establish a deeper understanding of the phenomenon to identify effective technical and pedagogical dimensions of: e-learning on user perspectives and finally to develop a scale: to fill the gap detected in the area of assessing/measuring Technical and pedagogical service quality of e- Leaning which can be used by designers and practitioners in the field of e-learning. A comprehensive methodology will be used to design the instrument.

  16. COMMUNITY CAPACITY BUILDING FOR REVITALIZATION AND SUSTAINABLE REDEVELOPMENT

    Energy Technology Data Exchange (ETDEWEB)

    Downing, Melinda; Rosenthall, John; Hudson, Michelle

    2003-02-27

    Capacity building programs help poor and disadvantaged communities to improve their ability to participate in the environmental decision-making processes. They encourage citizen involvement, and provide the tools that enable them to do so. Capacity building enables communities that would otherwise be excluded to participate in the process, leading to better, and more just decisions. The Department of Energy (DOE) continues to be committed to promoting environmental justice and involving its stakeholders more directly in the planning and decision-making process for environmental cleanup. DOE's Environmental Management Program (EM) is in full support of this commitment. Through its environmental justice project, EM provides communities with the capacity to effectively contribute to a complex technical decision-making process by furnishing access to computers, the Internet, training and technical assistance. DOE's Dr. Samuel P. Massie Chairs of Excellence Program (Massie Chairs) function as technical advisors to many of these community projects. The Massie Chairs consist of nationally and internationally recognized engineers and scientists from nine Historically Black Colleges and Universities (HBCUs) and one Hispanic Serving Institution (HIS). This paper will discuss capacity building initiatives in various jurisdictions.

  17. An Algorithm of Building Extraction in Urban Area Based on Improved Top-hat Transformations and LBP Elevation Texture

    Directory of Open Access Journals (Sweden)

    HE Manyun

    2017-09-01

    Full Text Available Classification of building and vegetation is difficult solely by LiDAR data and vegetation in shadows can't be eliminated only by aerial images. The improved top-hat transformations and local binary patterns (LBP elevation texture analysis for building extraction are proposed based on the fusion of aerial images and LiDAR data. Firstly, LiDAR data is reorganized into grid cell, the algorithm removes ground points through top-hat transform. Then, the vegetation points are extracted by normalized difference vegetation index (NDVI. Thirdly, according to the elevation information of LiDAR points, LBP elevation texture is calculated and achieving precise elimination of vegetation in shadows or surrounding to the buildings. At last, morphological operations are used to fill the holes of building roofs, and region growing for complete building edges. The simulation is based on the complex urban area in Vaihingen benchmark provided by ISPRS, the results show that the algorithm affording higher classification accuracy.

  18. Energy policy instruments and technical change in the residential building sector

    International Nuclear Information System (INIS)

    Beerepoot, W.M.C.

    2007-01-01

    The passing by the European Parliament of the Energy Performance of Buildings Directive (EPBD) in 2003 obliges all European member states to implement energy regulations for buildings based on the concept of energy performance by the year 2009 ultimately. Given the importance of the development of innovations in energy technology, and a transition to a sustainable energy supply system, it is necessary that policy instruments for energy conservation in the building sector stimulate the development and diffusion of innovations. This thesis contributes to knowledge about the content of energy performance policy and concludes that the effect of Dutch energy performance policy in encouraging innovation is limited. Energy efficiency improvements, by energy performance policy, seem to have come from the overall optimisation of all the energy related features of residential buildings. Insulation levels improved, although not spectacular. Efficiencies of heating technology improved, although this seems partly to be a result of the ongoing development that started in the 1980s. The efficiency of fans used for ventilation improved, as did the efficiency of all sorts of auxiliary devices needed in heating technology, as well as the efficiency of heat recovery in balanced ventilation systems. Although energy performance policy seems to have contributed to the optimisation of all energy related features of residential buildings, it did not cause a breakthrough of innovative technology such as solar thermal systems or heat pumps. The study of the innovation system of the Dutch construction industry identifies how the project-based nature of the construction industry is an obstacle to 'learning-rich' collaboration between the various stakeholders. The study contributes to the discussion about the impact of government policy for energy conservation in the building sector, in the context of climate change policy.

  19. A Comprehensive Review of Selected Business Programs in Community Colleges and Area Vocational-Technical Centers. Program Review Report.

    Science.gov (United States)

    Florida State Dept. of Education, Tallahassee. Div. of Vocational, Adult, and Community Education.

    In 1988, a review was conducted of the business component of associate in arts and associate in science (AS) degree programs, and of the certificate programs in business in Florida community colleges and area vocational-technical centers. Focusing primarily on business programs in marketing, general business management, and small business…

  20. Sustainable Development of Heritage Areas: Towards Cyber-Physical Systems Integration in Extant Heritage Buildings and Planning Conservation

    Directory of Open Access Journals (Sweden)

    Laila Mohamed Khodeir

    2017-03-01

    Full Text Available Although architectural heritage reflects the evolution of human civilization throughout history, nevertheless, civilized and social changes of heritage areas in many countries led to their degradation. Historical building management and planning conservation raise two important issues: the restoration and improvement of historical areas features and adopting a framework of sustainable development in heritage regions. Recently a number of processes have arose to aid in the aforementioned problems, namely the heritage building information modelling (HBIM and the  cyber-physical systems approach (CPS, where the latter is believed to  achieve great potentials hereby integrating virtual models and physical construction and  enabling bidirectional coordination. Since HBIM has recently been investigated through a number of recent research and application, the aim of this paper is to explore the potentials offered by the CPS, to move from 3D content model to bi-dimensional coordination for achieving efficient management of built heritage. To tackle the objective of this paper, firstly, a review of the BIM use in the field of cultural heritage  was undergone, Secondly, reporting the existing BIM/HBIM platforms, analyzing cyber-physical systems integration in extant heritage buildings and in planning conservation were performed. Results of this paper took the form of detailed comparative analysis between both CPS and HBIM, which could guide decision makers working in the field of heritage buildings management, in addition to shedding light on the main potentials of the emerging CPS.

  1. International Collaboration on Building Local Technical Capacities for Monitoring Volcanic Activity at Pacaya Volcano, Guatemala.

    Science.gov (United States)

    Escobar-Wolf, R. P.; Chigna, G.; Morales, H.; Waite, G. P.; Oommen, T.; Lechner, H. N.

    2015-12-01

    Pacaya volcano is a frequently active and potentially dangerous volcano situated in the Guatemalan volcanic arc. It is also a National Park and a major touristic attraction, constituting an important economic resource for local municipality and the nearby communities. Recent eruptions have caused fatalities and extensive damage to nearby communities, highlighting the need for risk management and loss reduction from the volcanic activity. Volcanic monitoring at Pacaya is done by the Instituto Nacional de Sismologia, Vulcanologia, Meteorologia e Hidrologia (INSIVUMEH), instrumentally through one short period seismic station, and visually by the Parque Nacional Volcan de Pacaya y Laguna de Calderas (PNVPLC) personnel. We carry out a project to increase the local technical capacities for monitoring volcanic activity at Pacaya. Funding for the project comes from the Society of Exploration Geophysicists through the Geoscientists Without Borders program. Three seismic and continuous GPS stations will be installed at locations within 5 km from the main vent at Pacaya, and one webcam will aid in the visual monitoring tasks. Local educational and outreach components of the project include technical workshops on data monitoring use, and short thesis projects with the San Carlos University in Guatemala. A small permanent exhibit at the PNVPLC museum or visitor center, focusing on the volcano's history, hazards and resources, will also be established as part of the project. The strategy to involve a diverse group of local collaborators in Guatemala aims to increase the chances for long term sustainability of the project, and relies not only on transferring technology but also the "know-how" to make that technology useful. Although not a primary research project, it builds on a relationship of years of joint research projects at Pacaya between the participants, and could be a model of how to increase the broader impacts of such long term collaboration partnerships.

  2. New Orleans Capacity Building Pilot Project

    Science.gov (United States)

    A series of meetings involving the Port of New Orleans and near-port community organizations were convened for a community capacity building pilot project. Technical assistance is being provided by EPA to support effective engagement.

  3. Radionuclide contaminant analysis of small mammals at Area G, Technical Area 54, 1996 (with cumulative summary for 1994--1996)

    International Nuclear Information System (INIS)

    Biggs, J.R.; Bennett, K.D.; Fresquez, P.R.

    1997-07-01

    Small mammals were sampled at two waste burial sites at Area G, Technical Area (TA) 54 and a control site within the proposed Area G expansion area in 1996 to (1) identify radionuclides that are present within rodent tissues at waste burial sites, (2) to compare the amount of radionuclide uptake by small mammals at waste burial sites to a control site, and (3) to identify the primary mode of contamination to small mammals, either through surface contact or ingestion/inhalation. Three composite samples of approximately five animals per sample were collected at each site. Pelts and carcasses of each animal were separated and analyzed independently. Samples were analyzed for 241 Am, 90 Sr, 238 Pu, 239 Pu, total U, 137 Cs, and 3 H. Higher levels of total U, 241 Am, 238 Pu, and 239 Pu were detected in pelts as compared to the carcasses of small mammals at TA-54. Concentrations of other measured radionuclides in carcasses were nearly equal to or exceeded the mean concentrations in the pelts. Due to low sample sizes in total number of animals captured, statistical analysis to compare site to site could not be conducted. However, mean concentrations of total U, 238 Pu, 239 Pu, and 137 Cs in rodent carcasses were higher at Site 1 than site 2 or the Control Site and 241 Am was higher at Site 2 than Site 1 or the Control Site

  4. Bioinjection Performance Review for the Building 100 Area and 4.5 Acre Site at the Pinellas County, Florida, Site

    Energy Technology Data Exchange (ETDEWEB)

    Survochak, Scott [US Department of Energy, Washington, DC (United States). Office of Legacy Management; Daniel, Joe [Navarro Research and Engineering, Oak Ridge, TN (United States)

    2016-05-01

    This document provides a summary of a review of the performance of bioinjection activities at the Building 100 Area and the 4.5 Acre Site at the Pinellas County, Florida, Site since 2010, determines how best to optimize future injection events, and identifies the approach for the bioinjection event in 2016 at (1) the 4.5 Acre Site and (2) the Essentra property at the Building 100 Area. Because this document describes the next bioinjection event at the 4.5 Acre Site, it also serves as an addendum to the Interim Remedial Action Plan for Emulsified Edible Oil Injection at the 4.5 Acre Site (DOE 2013). In addition, this document revises the injection layout and injection intervals for the Essentra property that were originally described in the Interim Corrective Measure Work Plan for Source and Plume Treatment at the Building 100 Area (DOE 2014), and is a de facto update of that document. Bioinjection consists of injection of emulsified vegetable oil (EVO) and the microorganism Dehalococcoides mccartyi (DHM; formerly known as Dehalococcoides ethenogenes) into the subsurface to enhance biodegradation of trichloroethene (TCE), dichloroethene (DCE), and vinyl chloride (VC). VC is the only contaminant that exceeds its maximum contaminant level (10 micrograms per liter onsite and 1 microgram per liter onsite) on the 4.5 Acre Site and the Essentra property. Bioinjection was conducted at the 4.5 Acre Site in 2010 and 2013. Approximately 49,900 gallons of EVO and DHM were injected at 95 injection points in February 2010, and approximately 22,900 gallons of EVO and DHM were injected at 46 injection points in July 2013. The injection locations are shown on Figure 1. The goal of bioinjection at the 4.5 Acre Site is to decrease contaminant concentrations to maximum contaminant levels along the west and southwest property boundaries (to meet risk–based corrective action requirements) and to minimize the extent of the contaminant plume in the interior of the site. Bioinjection was

  5. Cooperative Monitoring Center Occasional Paper/13: Cooperative monitoring for confidence building: A case study of the Sino-Indian border areas

    Energy Technology Data Exchange (ETDEWEB)

    SIDHU,WAHEGURU PAL SINGH; YUAN,JING-DONG; BIRINGER,KENT L.

    1999-08-01

    This occasional paper identifies applicable cooperative monitoring techniques and develops models for possible application in the context of the border between China and India. The 1993 and 1996 Sino-Indian agreements on maintaining peace and tranquility along the Line of Actual Control (LAC) and establishing certain confidence building measures (CBMs), including force reductions and limitation on military exercises along their common border, are used to examine the application of technically based cooperative monitoring in both strengthening the existing terms of the agreements and also enhancing trust. The paper also aims to further the understanding of how and under what conditions technology-based tools can assist in implementing existing agreements on arms control and confidence building. The authors explore how cooperative monitoring techniques can facilitate effective implementation of arms control agreements and CBMS between states and contribute to greater security and stability in bilateral, regional, and global contexts.

  6. 2011 Residential Energy Efficiency Technical Update Meeting Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2011-11-01

    This report provides an overview of the U.S. Department of Energy Building America program's Summer 2011 Residential Energy Efficiency Technical Update Meeting. This meeting was held on August 9-11, 2011, in Denver, Colorado, and brought together more than 290 professionals representing organizations with a vested interest in energy efficiency improvements in residential buildings.

  7. Technical Feasibility Study for Zero Energy K-12 Schools

    Energy Technology Data Exchange (ETDEWEB)

    Bonnema, Eric [National Renewable Energy Lab. (NREL), Golden, CO (United States); Goldwasser, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Torcellini, Paul [National Renewable Energy Lab. (NREL), Golden, CO (United States); Pless, Shanti [National Renewable Energy Lab. (NREL), Golden, CO (United States); Studer, Daniel [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-11-01

    This technical feasibility study provides documentation and research results supporting a possible set of strategies to achieve source zero energy K-12 school buildings as defined by the U.S. Department of Energy (DOE) zero energy building (ZEB) definition (DOE 2015a). Under this definition, a ZEB is an energy-efficient building in which, on a source energy basis, the actual annual delivered energy is less than or equal to the on-site renewable exported energy.

  8. Building America Systems Integration Research Annual Report: FY 2012

    Energy Technology Data Exchange (ETDEWEB)

    Gestwick, M.

    2013-05-01

    This document is the Building America FY2012 Annual Report, which includes an overview of the Building America Program activities and the work completed by the National Renewable Energy Laboratory and the Building America industry consortia (the Building America teams). The annual report summarizes major technical accomplishments and progress towards U.S. Department of Energy Building Technologies Program's multi-year goal of developing the systems innovations that enable risk-free, cost effective, reliable and durable efficiency solutions that reduce energy use by 30%-50% in both new and existing homes.

  9. Building America Systems Integration Research Annual Report. FY 2012

    Energy Technology Data Exchange (ETDEWEB)

    Gestwick, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-05-01

    This Building America FY2012 Annual Report includes an overview of the Building America Program activities and the work completed by the National Renewable Energy Laboratory and the Building America industry consortia (the Building America teams). The annual report summarizes major technical accomplishments and progress towards U.S. Department of Energy Building Technologies Program's multi-year goal of developing the systems innovations that enable risk-free, cost effective, reliable and durable efficiency solutions that reduce energy use by 30%-50% in both new and existing homes.

  10. A fuzzy-based model to implement the global safety buildings index assessment for agri-food buildings

    Directory of Open Access Journals (Sweden)

    Francesco Barreca

    2014-06-01

    Full Text Available The latest EU policies focus on the issue of food safety with a view to ensuring adequate and standard quality levels for the food produced and/or consumed within the EC. To that purpose, the environment where agricultural products are manufactured and processed plays a crucial role in achieving food hygiene. As a consequence, it is of the outmost importance to adopt proper building solutions which meet health and hygiene requirements as well as to use suitable tools to measure the levels achieved. Similarly, it is necessary to verify and evaluate the level of workers’ safety and welfare in their working environment. Workers’ safety has not only an ethical and social value but also an economic implication, since possible accidents or environmental stressors are the major causes of the lower efficiency and productivity of workers. Therefore, it is fundamental to design suitable models of analysis that allow assessing buildings as a whole, taking into account both health and hygiene safety as well as workers’ safety and welfare. Hence, this paper proposes an assessment model that, based on an established study protocol and on the application of a fuzzy logic procedure, allows assessing the global safety level of an agri-food building by means of a global safety buildings index. The model here presented is original since it uses fuzzy logic to evaluate the performances of both the technical and environmental systems of an agri-food building in terms of health and hygiene safety of the manufacturing process as well as of workers’ health and safety. The result of the assessment is expressed through a triangular fuzzy membership function which allows carrying out comparative analyses of different buildings. A specific procedure was developed to apply the model to a case study which tested its operational simplicity and the validity of its results. The proposed model allows obtaining a synthetic and global value of the building performance of

  11. Technical Site Information: Planning group of the Directorate and Conventional Construction Division

    International Nuclear Information System (INIS)

    1993-11-01

    This document presents the technical site information for the Superconducting Super Collider project. The Ellis County, Texas site was selected by the Department of Energy in 1989. After assembling the initial staff at temporary facilities in Dallas, the SSC Laboratory began site-specific design work. The resulting design for the SSC accelerators, experimental areas, and laboratory facilities were described in the Site-Specific Conceptual Design Report of July 1990. Since then, design specifications for the technical components and conventional facilities have been formulated. In fact, a very significant amount of surface and underground construction has been initiated and many buildings have been completed. Testing of prototypes for most technical components is advanced. The construction phase of the SSC project is approximately 20% complete. At this time, it is appropriate to capture the conventional design work which has taken place since 1990. This documents records regional and physical information used in site studies, summarizes the site studies for conventional facilities, and presents site layouts for buildings and utilities as they would have been at the end of the construction project. As such, this documents summarizes and complements the work of many groups in the SSC laboratory, the Texas National Research Laboratory Commission (TNRLC), and several subcontractors to the SSC project. The document contains extensive references to their work contained in other drafts and final reports. In particular, it borrows heavily from the Site Development Plan (released in draft form in January, 1992) which has, to date, guided aspects of site development

  12. Technical Site Information: Planning group of the Directorate and Conventional Construction Division

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-11-01

    This document presents the technical site information for the Superconducting Super Collider project. The Ellis County, Texas site was selected by the Department of Energy in 1989. After assembling the initial staff at temporary facilities in Dallas, the SSC Laboratory began site-specific design work. The resulting design for the SSC accelerators, experimental areas, and laboratory facilities were described in the Site-Specific Conceptual Design Report of July 1990. Since then, design specifications for the technical components and conventional facilities have been formulated. In fact, a very significant amount of surface and underground construction has been initiated and many buildings have been completed. Testing of prototypes for most technical components is advanced. The construction phase of the SSC project is approximately 20% complete. At this time, it is appropriate to capture the conventional design work which has taken place since 1990. This documents records regional and physical information used in site studies, summarizes the site studies for conventional facilities, and presents site layouts for buildings and utilities as they would have been at the end of the construction project. As such, this documents summarizes and complements the work of many groups in the SSC laboratory, the Texas National Research Laboratory Commission (TNRLC), and several subcontractors to the SSC project. The document contains extensive references to their work contained in other drafts and final reports. In particular, it borrows heavily from the Site Development Plan (released in draft form in January, 1992) which has, to date, guided aspects of site development.

  13. The life cycle cost of a building from the point of view of environmental criteria of selecting the most beneficial offer in the area of competitive tendering

    Directory of Open Access Journals (Sweden)

    Grzyl Beata

    2017-01-01

    Full Text Available The article analyses environmental and ecological criteria of selecting the most beneficial offer in the aspect of LCC. Construction works contracts and the potential method of defining the above criteria, among others, is pondered on (for example by the recommendation of a material, which is supposed to be used, a ban on substances that are harmful for human health as well for the environment. In the relation to the above, it is necessary to define technical parameters that have an impact on the environment, for example the level of pollution and noise emission, electricity and water consumption, or stating the minimal involvement of a processed ingredient. In addition the article presents also an account of the life cycle cost of a building from the point of view of environmental criteria constituting an element of selecting the most beneficial offer in the area of competitive tendering.

  14. General Merchandise 50% Energy Savings Technical Support Document

    Energy Technology Data Exchange (ETDEWEB)

    Hale, E.; Leach, M.; Hirsch, A.; Torcellini, P.

    2009-09-01

    This report documents technical analysis for medium-box general merchandise stores aimed at providing design guidance that achieves whole-building energy savings of at least 50% over ASHRAE Standard 90.1-2004.

  15. Building Blocks for Sustainable Communities: Assistance from Grantees

    Science.gov (United States)

    EPA awarded Building Blocks for Sustainable Communities grants to four nonprofit organizations with extensive expertise in community sustainability. These organizations deliver technical assistance to communities.

  16. Building Energy Efficiency through Innovative Thermodevices (BEEIT)

    Energy Technology Data Exchange (ETDEWEB)

    Ju, Y. Sungtaek [Univ. of California, Los Angeles, CA (United States); Dunn, Bruce [Univ. of California, Los Angeles, CA (United States); Pei, Qibing [Univ. of California, Los Angeles, CA (United States); Kim, C. -J. [Univ. of California, Los Angeles, CA (United States)

    2012-12-14

    This is the final scientific/technical report for the project "Compact MEMS Electrocaloric Cooling Module" sponsored by ARAPA-E as part of its Building Energy Efficiency through Innovative Thermodevices (BEEIT) program.

  17. Bio-aggregates based building materials state-of-the-art report of the RILEM Technical Committee 236-BBM

    CERN Document Server

    Collet, Florence

    2017-01-01

    The work of the RILEM Technical Committee (TC -236 BBM) was dedicated to the study of construction materials made from plant particles. It considered the question whether building materials containing as main raw material recyclable and easily available plant particles are renewable. This book includes a state-of-the-art report and an appendix. The state-of-the-art report relates to the description of vegetal aggregates. Then, hygrothermal properties, fire resistance, durability and finally the impact of the variability of the method of production of bio-based concrete are assessed. The appendix is a TC report which presents the experience of a working group. The goal was to define testing methods for the measurement of water absorption, bulk density, particle size distribution, and thermal conductivity of bio aggregates. The work is based on a first round robin test of the TC-BBM where the protocols in use by the different laboratories (labs) are compared. .

  18. Technical Safety Requirements for the Waste Storage Facilities

    International Nuclear Information System (INIS)

    Larson, H L

    2007-01-01

    This document contains Technical Safety Requirements (TSR) for the Radioactive and Hazardous Waste Management (RHWM) WASTE STORAGE FACILITIES, which include Area 612 (A612) and the Decontamination and Waste Treatment Facility (DWTF) Storage Area at Lawrence Livermore National Laboratory (LLNL). The TSRs constitute requirements regarding the safe operation of the WASTE STORAGE FACILITIES. These TSRs are derived from the Documented Safety Analysis for the Waste Storage Facilities (DSA) (LLNL 2006). The analysis presented therein determined that the WASTE STORAGE FACILITIES are low-chemical hazard, Hazard Category 2 non-reactor nuclear facilities. The TSRs consist primarily of inventory limits and controls to preserve the underlying assumptions in the hazard and accident analyses. Further, appropriate commitments to safety programs are presented in the administrative controls sections of the TSRs. The WASTE STORAGE FACILITIES are used by RHWM to handle and store hazardous waste, TRANSURANIC (TRU) WASTE, LOW-LEVEL WASTE (LLW), mixed waste, California combined waste, nonhazardous industrial waste, and conditionally accepted waste generated at LLNL as well as small amounts from other U.S. Department of Energy (DOE) facilities, as described in the DSA. In addition, several minor treatments (e.g., drum crushing, size reduction, and decontamination) are carried out in these facilities. The WASTE STORAGE FACILITIES are located in two portions of the LLNL main site. A612 is located in the southeast quadrant of LLNL. The A612 fenceline is approximately 220 m west of Greenville Road. The DWTF Storage Area, which includes Building 693 (B693), Building 696 Radioactive Waste Storage Area (B696R), and associated yard areas and storage areas within the yard, is located in the northeast quadrant of LLNL in the DWTF complex. The DWTF Storage Area fenceline is approximately 90 m west of Greenville Road. A612 and the DWTF Storage Area are subdivided into various facilities and storage

  19. Technical Safety Requirements for the Waste Storage Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Larson, H L

    2007-09-07

    This document contains Technical Safety Requirements (TSR) for the Radioactive and Hazardous Waste Management (RHWM) WASTE STORAGE FACILITIES, which include Area 612 (A612) and the Decontamination and Waste Treatment Facility (DWTF) Storage Area at Lawrence Livermore National Laboratory (LLNL). The TSRs constitute requirements regarding the safe operation of the WASTE STORAGE FACILITIES. These TSRs are derived from the Documented Safety Analysis for the Waste Storage Facilities (DSA) (LLNL 2006). The analysis presented therein determined that the WASTE STORAGE FACILITIES are low-chemical hazard, Hazard Category 2 non-reactor nuclear facilities. The TSRs consist primarily of inventory limits and controls to preserve the underlying assumptions in the hazard and accident analyses. Further, appropriate commitments to safety programs are presented in the administrative controls sections of the TSRs. The WASTE STORAGE FACILITIES are used by RHWM to handle and store hazardous waste, TRANSURANIC (TRU) WASTE, LOW-LEVEL WASTE (LLW), mixed waste, California combined waste, nonhazardous industrial waste, and conditionally accepted waste generated at LLNL as well as small amounts from other U.S. Department of Energy (DOE) facilities, as described in the DSA. In addition, several minor treatments (e.g., drum crushing, size reduction, and decontamination) are carried out in these facilities. The WASTE STORAGE FACILITIES are located in two portions of the LLNL main site. A612 is located in the southeast quadrant of LLNL. The A612 fenceline is approximately 220 m west of Greenville Road. The DWTF Storage Area, which includes Building 693 (B693), Building 696 Radioactive Waste Storage Area (B696R), and associated yard areas and storage areas within the yard, is located in the northeast quadrant of LLNL in the DWTF complex. The DWTF Storage Area fenceline is approximately 90 m west of Greenville Road. A612 and the DWTF Storage Area are subdivided into various facilities and storage

  20. Prediction of 137Cs and 90Sr accumulation in milk of horses and sheep grazing the area adjacent to the 'Experimental Field' technical area of the Semipalatinsk test site

    International Nuclear Information System (INIS)

    Gontarenko, I.A.; Spiridonov, S.I.; Mukusheva, M.K.

    2005-01-01

    The paper describes mathematical models for 137 Cs and 90 Sr behavior in body of horses and sheep grazing the area adjacent to the 'Experimental Field' Technical Area of the Semipalatinsk test site. The models were parametrized on the basis of experimental data for those breeds of animals that are currently encountered within the Semipalatinsk test area. The predictive conclusions using devised models have shown that 137 Cs and 90 Sr concentration in milk of horses and sheep grazing the Experimental field are can exceed the adopted standards during a long period of time. (author)

  1. Tall-Building Projects Sustainability Indicator (TPSI: A New Design and Environmental Assessment Tool for Tall Buildings

    Directory of Open Access Journals (Sweden)

    Hasim Altan

    2012-04-01

    Full Text Available The paper presents the features of Tall-building Projects Sustainability Indicator (TPSI—a “Sustainability Rating System” that specializes in tall-building projects. The system comprises two components; the “Technical Manual” in the form of a booklet and the “Calculator” in the form of an Excel tool. It can be used as a “design tool” and/or as a “checklist” to compare and to improve the sustainable performance of tall-building design schemes. At the same time, the system can be used to evaluate the sustainability of existing tall-building projects. The first version of the TPSI rating system (TPSI 2012 Version was released as an online tool (GreenLight and thoroughly examined and validated by multiple parties.

  2. Innovative technologies of outsourcing at the machine-building enterprises of Sverdlovsk area

    Directory of Open Access Journals (Sweden)

    P. P. Krylatkov

    2010-09-01

    Full Text Available The analysis of the basic problems connected with infringements of integrity of the machine-building enterprises of Sverdlovsk area is lead in the article. The specified problems are considered from a position of the complete approach developed by the author. Display of infringements of integrity of some the enterprises are illustrated by data of their inspection. As the effective tool of increase of integrity of the enterprises — expansion use of attitudes of outsourcing is offered. The comparative given applications of outsourcing in developed the country of the West and at the domestic enterprises, and also its benefits and risks are cited. Outsourcing, insoursing and subcontracting are considered by the author as the innovative tool of the decision of many serious problems of the machine-building enterprises of region. As an example practice of work of «The Sverdlovsk regional center of industrial cooperation» on coordination of attitudes of outsourcing, subcontracting and cooperation is offered. The author recommends the tabulated form, with the instruction of kinds of works for which performance the method of allocation or attraction outsourcing of the companies can be used.

  3. Development of solar collector to integration in buildings; Udvikling af solfanger til integrering i bygninger

    Energy Technology Data Exchange (ETDEWEB)

    Holck, O.; Svendsen, S.

    2000-07-01

    A solar collector has been developed in the project. The development of the collector is based on knowledge from previous projects and the idea of combining existing exterior insulation systems with a solar collector part for renovation purpose. This solar collector especially focuses on the market, which is dedicated to concrete buildings. South heading gable/facade walls in concrete buildings have a potential for utilization of solar energy. With regards to commercial utilization of the results the project has building parts manufacturers and solar collector manufacturers in mind. Besides the housing stock the industry sector is an area where gable solar collectors can be used. To get the right link between the manufactured part and the building, an existing building is referred to in the project. A prefabricated insulation system from Paroc and a liquid heating absorber from Batec have been chosen as the basis of the project. 50 mm wide aluminium profiles from H.S. Hansen have been used, accomplishing a sliding joint to the adjacent building systems. A range of flashing, is available on the market, fits to the 50 mm profile. Based on these choices the concept of utilizing solar energy can be transferred without difficulties to be valid for other exterior insulation systems, absorber types and consumer systems. Technical details concerning profiles and assembling of solar collectors have been analysed in the project and can be seen from the technical drawings. The mounting of the solar collector will be done by crane so that the work can be done fast and efficiently. This is particularly important in narrow streets, as here is no need to establish building sites for a long period. Crane assembling is suitable when the walls have big areas without needs for many cuttings and projections. If there are windows in the gable a vertical assembling of the elements can be the solution as the windows are often placed in a straight line above each other. In the project

  4. Verification of the local structural response of building structures in the anchorage areas of heavy components

    International Nuclear Information System (INIS)

    Krutzik, N.J.; Tropp, R.

    1993-01-01

    In both nuclear and non-nuclear areas of power plants, sections of structures, parts of systems and components are attached to walls and floors by means of anchor plates with bolts, anchor sleeves and bolts and through bolts arranged either in groups or individually. In order to simplify the determination of the transfered vibrations induced by external events (e.g. earthquake, aircraft crash), it is normally assumed that the nodal point between component and concrete possesses rigid body characteristics and the building structure (walls, floors) is also inflexible in the anchorage area. In the course of the parametric studies performed, the nonlinear effects on the anchorage area of a component (in this case an anchor plate and concrete slab) were calculated and the effect of these on the actual vibration behavior and the local structural responses of the building structure at the place of installation of heavy components were investigated. The investigations performed reveal that by taking into account the local behaviour in the anchoring point, it is possible to reduce the dynamic response considerably. More detailed examination of the influence of additional parameters (especially of the geometry of the anchor plates and anchor bolts and their material characteristics) will require further investigations aimed at establishing the characteristics of typical anchor plates. (orig.)

  5. Gamma-ray and neutron area monitoring system of linear IFMIF prototype accelerator building

    International Nuclear Information System (INIS)

    Takahashi, Hiroki; Kojima, Toshiyuki; Narita, Takahiro; Tsutsumi, Kazuyoshi; Maebara, Sunao; Sakaki, Hironao; Nishiyama, Koichi

    2013-01-01

    Highlights: • Area monitoring system and control system are needed for LIPAc radiation management. • To secure the radiation safety, these systems are linked with two kinds of data path. • Hardwired data paths are adopted to realize the fast transfer of interlock signals. • Dual LAN and shared memory are adopted to the reliable transfer of monitoring data. • Data transfers without unnecessary load are designed and configured for these systems. -- Abstract: The linear IFMIF prototype accelerator (LIPAc) produces deuteron beam with 1 MW power. Since huge number of neutrons occur from such a high power beam, therefore, it is important for the radiation management to design a high reliability area monitoring system for gamma-rays and neutrons. To obtain the valuable operation data of the high-power deuteron beam at LIPAc, it is important to link and record the beam operation data and the area monitoring data. We realize the reliable data transfer to provide the area monitoring data to the accelerator control system which needs a high reliability using the shared-memory data link method. This paper describes the area monitoring system in the LIPAc building and the data-link between this system and the LIPAc control system

  6. Protection of historic buildings against environmental pollution of vibrations

    Directory of Open Access Journals (Sweden)

    Kowalska-Koczwara Alicja

    2016-01-01

    Full Text Available Historic buildings in Poland are largely neglected objects that small percentage is preserved in its original form. Unrelenting in the case of historic buildings is a time that brings with it the natural processes of aging of buildings, but also the history of the object which is often marked by military conflicts, fires or even incompetently carried out reconstruction. Nowadays historic buildings are also destroyed by the rapid development of infrastructure and residential construction. This development could lead to changes of water in the soil, make changes in the geologic al structure or cause exposure of the historic building to the new influences (eg. traffic vibrations, to which building has not been subjected so far. Vibrations are often omitted in environmental issues, although the protection against noise and vibration has its place in the Law on Environmental Protection. This article presents the methodology for the measurement and interpretation of vibration influence on historic buildings and the assessment methods of technical condition of historic building on the example of dynamic measurements made on St. Nicholas Church in Krakow. The importance of well-done crack-by-crack documentation and characterization of damages based on damage index is shown. Difficulties that can be encountered when determining the causes of technical condition of historic buildings are also shown. Based on the example of the Church in the article are also given the possible protection solutions of historic structures from vibrations.

  7. Evaluation of building fundamental periods and effects of local geology on ground motion parameters in the Siracusa area, Italy

    Science.gov (United States)

    Panzera, Francesco; D'Amico, Sebastiano; Lombardo, Giuseppe; Longo, Emanuela

    2016-07-01

    The Siracusa area, located in the southeastern coast of Sicily (Italy), is mainly characterized by the outcropping of a limestone formation. This lithotype, which is overlain by soft sediments such as sandy clays and detritus, can be considered as the local bedrock. Records of ambient noise, processed through spectral ratio techniques, were used to assess the dynamic properties of a sample survey of both reinforced concrete and masonry buildings. The results show that experimental periods of existing buildings are always lower than those proposed by the European seismic code. This disagreement could be related to the role played by stiff masonry infills, as well as the influence of adjacent buildings, especially in downtown Siracusa. Numerical modeling was also used to study the effect of local geology on the seismic site response of the Siracusa area. Seismic urban scenarios were simulated considering a moderate magnitude earthquake (December 13th, 1990) to assess the shaking level of the different outcropping formations. Spectral acceleration at different periods, peak ground acceleration, and velocity were obtained through a stochastic approach adopting an extended source model code. Seismic ground motion scenario highlighted that amplification mainly occurs in the sedimentary deposits that are widespread to the south of the study area as well as on some spot areas where coarse detritus and sandy clay outcrop. On the other hand, the level of shaking appears moderate in all zones with outcropping limestone and volcanics.

  8. Influence of pulse electromagnetic fields on electronic equipment and systems in smart buildings

    Directory of Open Access Journals (Sweden)

    Jacek Paś

    2016-07-01

    Full Text Available The article presents information about the impact of electromagnetic fields’ impulses on technical infrastructure of electronic equipment and systems in intelligent buildings. The use of modern technical solutions in intelligent building management, i.e., human resources control and automation systems, efficient building space management, requires a large number of integrated electronic systems. Impulse interference, lightning or electricity as natural phenomena are among the most responsible for the occurrence of interference in buses, transmission lines systems, electrical installations, equipment and electronic systems used in intelligent buildings. To a large extent, it is associated with catastrophic damages that may occur in electronic devices or in completed systems such as intelligent building, e.g. ICT, security, etc. under the influence of induced voltages and interfering signals’ currents. Keywords: noise, static electricity, lightning

  9. Energy Efficiency of Higher Education Buildings: A Case Study

    Science.gov (United States)

    Soares, Nelson; Pereira, Luísa Dias; Ferreira, João; Conceição, Pedro; da Silva, Patrícia Pereira

    2015-01-01

    Purpose: This paper aims to propose an energy efficiency plan (with technical and behavioural improvement measures) for a Portuguese higher education building--the Teaching Building of the Faculty of Economics of the University of Coimbra (FEUC). Design/methodology/approach: The study was developed in the context of both the "Green…

  10. BUILD: A community development simulation game, appendix A

    Science.gov (United States)

    Orlando, J. A.; Pennington, A. J.

    1973-01-01

    The computer based urban decision-making game BUILD is described. BUILD is aimed at: (1) allowing maximum expression of value positions by participants through resolution of intense, task-oriented conflicts: (2) heuristically gathering information on both the technical and social functioning of the city through feedback from participants: (3) providing community participants with access to technical expertise in urban decision making, and to expose professionals to the value positions of the community: and (4) laying the groundwork for eventual development of an actual policy making tool. A brief description of the roles, sample input/output formats, an initial scenario, and information on accessing the game through a time-sharing system are included.

  11. Putting science into practice: saving energy in buildings

    Energy Technology Data Exchange (ETDEWEB)

    Shove, E.

    1994-12-31

    A research project is described which has investigated the relationship between science-based knowledge of energy efficient building and practical energy saving action. A comparison of government funded research and development programmes has shown how knowledge of energy efficient building technology has been developed and applied. Beliefs about the nature of social change which underly these technical programmes have been revealed by an analysis of the theory and practice of technology transfer. An examination of three specific energy saving action contexts illustrates the tensions between standardised scientific knowledge and the diverse social and organisational situations in which technical expertise is applied. The report raises questions about the interaction of natural and social science and environmental policy. (UK)

  12. 'Experience the future of building technologies'. High tech, low energy

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    These proceedings cover the contributions presented at the CLIMA 2005 conference held in Lausanne, Switzerland. This four-day conference was sponsored by a large number of companies and organisations active in the Swiss building technologies area. Several keynote lectures were presented as were awards to students active in the building technical services area. The proceedings document the papers presented at the conference. These covered nine main topics. The first, 'Air-conditioning and ventilation' comprised 43 papers on the indoor environment, 15 on room air distribution, 4 on hygiene, 11 on alternative cooling methods, 8 on air-flow, 2 on air-cleaning and filters, 6 on refurbishment and even one concerning air-flow predictions in Egyptian tombs. The second topic, 'Heating', comprised 13 contributions on low-temperature heating and heat pumps, 7 on distributed energy systems, 4 on district heating, 7 on solar heating systems and 3 miscellaneous items. 'Design methods' were examined as a third topic with 11 contributions on building-simulation tools and 26 on computer-based methods for design, construction and operation. In the fourth section, 'Refrigeration', papers were presented on new working fluids (3 contributions), modernisation (5) along with 4 miscellaneous papers. 'Policies, standards and building-codes' were examined in four categories: Implementation of the European Energy Performance Directive with 8 contributions, life-cycle costs with 2 papers, energy conservation with 15 contributions and 2 contributions in the miscellaneous category. 'Domestic water systems and sanitary technology', the sixth section, includes 3 contributions on water conservation. Section 7, 'Building automation, security and control' includes a section on information and communication systems (3 contributions) and 6 various papers. Section 8, 'Building physics and HVAC' includes 8 contributions on double-skin and high-tech building envelopes, 7 on moisture control, and one on

  13. Predictive Solar-Integrated Commercial Building Load Control

    Energy Technology Data Exchange (ETDEWEB)

    Glasgow, Nathan [EdgePower Inc., Aspen, CO (United States)

    2017-01-31

    This report is the final technical report for the Department of Energy SunShot award number EE0007180 to EdgePower Inc., for the project entitled “Predictive Solar-Integrated Commercial Building Load Control.” The goal of this project was to successfully prove that the integration of solar forecasting and building load control can reduce demand charge costs for commercial building owners with solar PV. This proof of concept Tier 0 project demonstrated its value through a pilot project at a commercial building. This final report contains a summary of the work completed through he duration of the project. Clean Power Research was a sub-recipient on the award.

  14. Energy savings in Danish residential building stock

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Svendsen, Svend

    2006-01-01

    a short account of the technical energy-saving possibilities that are present in existing dwellings and presents a financial methodology used for assessing energy-saving measures. In order to estimate the total savings potential detailed calculations have been performed in a case with two typical...... buildings representing the residential building stock and based on these calculations an assessment of the energy-saving potential is performed. A profitable savings potential of energy used for space heating of about 80% is identified over 45 years (until 2050) within the residential building stock......A large potential for energy savings exists in the Danish residential building stock due to the fact that 75% of the buildings were constructed before 1979 when the first important demands for energy performance of building were introduced. It is also a fact that many buildings in Denmark face...

  15. The SISTA pilot project: understanding the training and technical assistance needs of community-based organizations implementing HIV prevention interventions for African American women--implications for a capacity building strategy.

    Science.gov (United States)

    Fuller, Taleria R; Brown, Mari; King, Winifred; Prather, Cynthia; Cazaubon, Janine; Mack, Justin; Russell, Brandi

    2007-01-01

    The disproportionate rates of HIV/AIDS among African American women in the U.S. signify the ongoing need for targeted HIV prevention interventions. Additionally, building the capacity of service providers to sustain prevention efforts is a major concern. The Centers for Disease Control and Prevention (CDC) conducted a pilot project to disseminate the Sisters Informing Sisters about Topics on AIDS (SISTA), an HIV prevention intervention designed for African American women. The project was to inform the diffusion process and examine the training and technical assistance needs of participating community-based organizations. Results demonstrated a need for extensive pre-planning and skills-building prior to implementation.

  16. Automatic generation and simulation of urban building energy models based on city datasets for city-scale building retrofit analysis

    International Nuclear Information System (INIS)

    Chen, Yixing; Hong, Tianzhen; Piette, Mary Ann

    2017-01-01

    Highlights: •Developed methods and used data models to integrate city’s public building records. •Shading from neighborhood buildings strongly influences urban building performance. •A case study demonstrated the workflow, simulation and analysis of building retrofits. •CityBES retrofit analysis feature provides actionable information for decision making. •Discussed significance and challenges of urban building energy modeling. -- Abstract: Buildings in cities consume 30–70% of total primary energy, and improving building energy efficiency is one of the key strategies towards sustainable urbanization. Urban building energy models (UBEM) can support city managers to evaluate and prioritize energy conservation measures (ECMs) for investment and the design of incentive and rebate programs. This paper presents the retrofit analysis feature of City Building Energy Saver (CityBES) to automatically generate and simulate UBEM using EnergyPlus based on cities’ building datasets and user-selected ECMs. CityBES is a new open web-based tool to support city-scale building energy efficiency strategic plans and programs. The technical details of using CityBES for UBEM generation and simulation are introduced, including the workflow, key assumptions, and major databases. Also presented is a case study that analyzes the potential retrofit energy use and energy cost savings of five individual ECMs and two measure packages for 940 office and retail buildings in six city districts in northeast San Francisco, United States. The results show that: (1) all five measures together can save 23–38% of site energy per building; (2) replacing lighting with light-emitting diode lamps and adding air economizers to existing heating, ventilation and air-conditioning (HVAC) systems are most cost-effective with an average payback of 2.0 and 4.3 years, respectively; and (3) it is not economical to upgrade HVAC systems or replace windows in San Francisco due to the city’s mild

  17. Improving the energy performance of historic buildings with architectural and cultural values

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan de Place

    2017-01-01

    The thermal performance of solid walls of historic buildings can be improved by external or internal insulation. External insulation is preferred from a technical perspective, but is often disregarded as many such buildings have architectural or cultural values leaving internal insulation.......g. improvement of thermal indoor climate. The paper discusses different motivating factors for improving the thermal performance of solid walls in historic buildings with architectural and cultural values. It is argued that internal insulation, provided that it can be done without resulting in critical moisture...... as the only possible solution. As internal insulation is considered a risky way of improving the thermal performance from a moisture perspective, technically feasible solutions are needed. Further, other arguments than energy saving could convince a building owner to carry out internal insulation, e...

  18. Large Hospital 50% Energy Savings: Technical Support Document

    Energy Technology Data Exchange (ETDEWEB)

    Bonnema, E.; Studer, D.; Parker, A.; Pless, S.; Torcellini, P.

    2010-09-01

    This Technical Support Document documents the technical analysis and design guidance for large hospitals to achieve whole-building energy savings of at least 50% over ANSI/ASHRAE/IESNA Standard 90.1-2004 and represents a step toward determining how to provide design guidance for aggressive energy savings targets. This report documents the modeling methods used to demonstrate that the design recommendations meet or exceed the 50% goal. EnergyPlus was used to model the predicted energy performance of the baseline and low-energy buildings to verify that 50% energy savings are achievable. Percent energy savings are based on a nominal minimally code-compliant building and whole-building, net site energy use intensity. The report defines architectural-program characteristics for typical large hospitals, thereby defining a prototype model; creates baseline energy models for each climate zone that are elaborations of the prototype models and are minimally compliant with Standard 90.1-2004; creates a list of energy design measures that can be applied to the prototype model to create low-energy models; uses industry feedback to strengthen inputs for baseline energy models and energy design measures; and simulates low-energy models for each climate zone to show that when the energy design measures are applied to the prototype model, 50% energy savings (or more) are achieved.

  19. NEET-AMM Final Technical Report on Laser Direct Manufacturing (LDM) for Nuclear Power Components

    International Nuclear Information System (INIS)

    Anderson, Scott; Baca, Georgina; O'Connor, Michael

    2015-01-01

    Final technical report summarizes the program progress and technical accomplishments of the Laser Direct Manufacturing (LDM) for Nuclear Power Components project. A series of experiments varying build process parameters (scan speed and laser power) were conducted at the outset to establish the optimal build conditions for each of the alloys. Fabrication was completed in collaboration with Quad City Manufacturing Laboratory (QCML). The density of all sample specimens was measured and compared to literature values. Optimal build process conditions giving fabricated part densities close to literature values were chosen for making mechanical test coupons. Test coupons whose principal axis is on the x-y plane (perpendicular to build direction) and on the z plane (parallel to build direction) were built and tested as part of the experimental build matrix to understand the impact of the anisotropic nature of the process.. Investigations are described 316L SS, Inconel 600, 718 and 800 and oxide dispersion strengthed 316L SS (Yttria) alloys.

  20. NEET-AMM Final Technical Report on Laser Direct Manufacturing (LDM) for Nuclear Power Components

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Scott [Lockheed Martin Corporation, Denver, CO (United States). Space Systems Company; Baca, Georgina [Lockheed Martin Corporation, Denver, CO (United States). Space Systems Company; O' Connor, Michael [Lockheed Martin Corporation, Denver, CO (United States). Space Systems Company

    2015-12-31

    Final technical report summarizes the program progress and technical accomplishments of the Laser Direct Manufacturing (LDM) for Nuclear Power Components project. A series of experiments varying build process parameters (scan speed and laser power) were conducted at the outset to establish the optimal build conditions for each of the alloys. Fabrication was completed in collaboration with Quad City Manufacturing Laboratory (QCML). The density of all sample specimens was measured and compared to literature values. Optimal build process conditions giving fabricated part densities close to literature values were chosen for making mechanical test coupons. Test coupons whose principal axis is on the x-y plane (perpendicular to build direction) and on the z plane (parallel to build direction) were built and tested as part of the experimental build matrix to understand the impact of the anisotropic nature of the process.. Investigations are described 316L SS, Inconel 600, 718 and 800 and oxide dispersion strengthed 316L SS (Yttria) alloys.

  1. 從需求面探究技術學院教職員評鑑能力建立之內涵 The Needs in Evaluation Capacity Building of the Faculty in Technical Colleges

    Directory of Open Access Journals (Sweden)

    曾淑惠 Shu-Hui Tseng

    2009-12-01

    Full Text Available 評鑑能力建立在各國高等教育機構已有二十餘年的實踐歷程,我國技術學院在當前的評鑑成果下顯示,不僅技術學院的辦學品質有待提升,教職員的評鑑能力亦亟待加強。為奠立技術學院教職員評鑑能力建立的基礎,本研究旨在建構評鑑能力建立需求量表,並調查技術學院教職員對評鑑能力建立的需求程度。經文獻分析、訪談11 位專家、6 位專家審查及問卷調查1,054 位技術學院教職員後發現,技術學院教職員評鑑能力建立的需求,除了從文獻中所彙整的能力內涵外,尚由訪談發掘數項特殊需求;而不同背景教職員對於評鑑能力建立之需求程度,達統計上顯著水準,值得進一步探究成因。研究結論包括:一、評鑑能力建立需求量表包含「理解評鑑工作之方針」、「熟悉評鑑工作之要求」、「參與評鑑工作之運作」、以及「落實評鑑工作之內涵」等四大面向共21 題項,經驗證結果模式適配情形良好。二、技術學院教職員對評鑑能力建立的需求顯著高於高度需求的程度。最後根據研究結果,提出四項具體建議以供參考。 The evaluation capacity building has been practiced over twenty years among higher educational organizations. The results of technical college evaluation in our country reveal that both the quality of educational management and the evaluation capacity of the faculty need to be improved. To better build the foundation of the evaluation capacity for the faculty in technical colleges, the purpose of this study aims to construct the scale of the needs in evaluation capacity building and to investigate the demands of the staff in technical colleges on evaluation capacity building. The scale construction process includes the literature analysis, interview from 11 experts, consultation with 6 experts, and the questionnaires from 1,054 faculty in

  2. Engineering evaluation cost analysis for the 100-B/C area ancillary facilities at the 108-F Building

    International Nuclear Information System (INIS)

    1996-10-01

    In 1995, the US Department of Energy (DOE), Richland Operations Office (RL) conducted a removal site evaluation of selected facilities in the 100 Area of the Hanford Site in accordance with CERCLA and 40 Code of Federal Regulations (CFR) 300.410. The scope of the evaluation included the aboveground portions of the 108-F Biology Laboratory in the 100-F Area and all inactive ancillary buildings and structures in the 100-B/C Area, excluding the reactor building and the river outfall. Based on the evaluation, RL determined that hazardous substances in the 108-F Biology Laboratory and five of the 100-B/C Area facilities may present a potential threat to human health or the environment, and that a non-time critical removal action at these facilities is warranted. This determination was documented in an engineering evaluation/cost analysis (EE/CA) approval memorandum. The EE/CA approval memorandum is the basis on which to proceed with the performance of an EE/CA to determine the appropriate removal action. This report presents the results of the EE/CA for removal alternatives for final disposition of these six facilities. The EE/CA was conducted pursuant to the requirements of CERCLA and 40 CFR 300.415 and is intended to aid RL and the EPA in selecting a preferred removal action

  3. Environmental assessment for operations, upgrades, and modifications in SNL/NM Technical Area IV

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-04-01

    The proposed action for this EA for Sandia National Laboratories/New Mexico Technical Area IV, includes continuing existing operations, modification of an existing accelerator (Particle Beam Fusion Accelerator II) to support defnese-related Z-pinch experiments, and construction of two transformer oil storage tanks to support the expansion of the Advanced Pulsed Power Research Module, a single pulse accelerator. Based on the analyses in the EA, DOE believes that the proposed action is not a major federal action significantly affecting the quality of the human environment within the meaning of NEPA and CEQ NEPA implementing regulations in 40 CFR 1508.18 and 1508.27. Therefore, an environmental impact statement is not required, and a Finding of No Significant Impact is issued.

  4. Environmental assessment for operations, upgrades, and modifications in SNL/NM Technical Area IV

    International Nuclear Information System (INIS)

    1996-04-01

    The proposed action for this EA for Sandia National Laboratories/New Mexico Technical Area IV, includes continuing existing operations, modification of an existing accelerator (Particle Beam Fusion Accelerator II) to support defnese-related Z-pinch experiments, and construction of two transformer oil storage tanks to support the expansion of the Advanced Pulsed Power Research Module, a single pulse accelerator. Based on the analyses in the EA, DOE believes that the proposed action is not a major federal action significantly affecting the quality of the human environment within the meaning of NEPA and CEQ NEPA implementing regulations in 40 CFR 1508.18 and 1508.27. Therefore, an environmental impact statement is not required, and a Finding of No Significant Impact is issued

  5. Technical snow production in skiing areas: conditions, practice, monitoring and modelling. A case study in Mayrhofen/Austria

    Science.gov (United States)

    Strasser, Ulrich; Hanzer, Florian; Marke, Thomas; Rothleitner, Michael

    2017-04-01

    The production of technical snow today is a self-evident feature of modern alpine skiing resort management. Millions of Euros are invested every year for the technical infrastructure and its operation to produce a homogeneous and continuing snow cover on the skiing slopes for the winter season in almost every larger destination in the Alps. In Austria, skiing tourism is a significant factor of the national economic structure. We present the framing conditions of technical snow production in the mid-size skiing resort of Mayrhofen (Zillertal Alps/Austria, 136 km slopes, elevation range 630 - 2.500 m a.s.l.). Production conditions are defined by the availability of water, the planned date for the season opening, and the climatic conditions in the weeks before. By means of an adapted snow production strategy an attempt is made to ecologically and economically optimize the use of water and energy resources. Monitoring of the snow cover is supported by a network of low-cost sensors and mobile snow depth recordings. Finally, technical snow production is simulated with the spatially distributed, physically based hydroclimatological model AMUNDSEN. The model explicitly considers individual snow guns and distributes the produced snow along the slopes. The amount of simulated snow produced by each device is a function of its type, of actual wet-bulb temperature at the location, of ski area infrastructure (in terms of water supply and pumping capacity), and of snow demand.

  6. Assessing the Land Subsidence Governance in Ningbo City: By a Close Study of the Building Collapse at the Strictly Protected Land Subsidence Area

    Science.gov (United States)

    Yu, Xia

    2016-04-01

    Ningbo is a coastal city in East China, its land subsidence problem was noticed in the 1960s. However, scientific management was insufficient at that time, so with the fast city development from the 1980s, groundwater was used by a large amount of small factories, and tall buildings were built on the land. It was in 2008, scientists predicted that if without doing anything to prevent the land from subsiding, the city will be covered by the East Sea in 2030. From then on, the local government implied several policies, such as shut down most of the groundwater pumping wells, set up a new authority to enhance the cooperation among different administration departments, and also set up a land subsidence monitoring center for the city. Recently, it is declared that a Stereo regulatory system of land subsidence governance has been achieved. However, in 2012, a 23-years old building in the city center collapsed. According to the City Planning 2009, this building is located just in the strictly protected land subsidence area. The experts, however, think that land subsidence is not the main reason, since there are many illegal changes to the building during the past 23 years. The aim of my research is to assess the land subsidence governance in Ningbo city. I studied the collapsed building, how it was built, what has changed after building, how the environment changed in this area, and how this area became the strictly protected land subsidence area, and what kind of protections have been made. Actually, during the case study I discuss the land subsidence governance design of Ningbo, and to see what practices and lessons we can learn from this case.

  7. Launching a nuclear nower programme in a developing country - Technical and Scientific Support Organisations (TSO) in capacity building

    International Nuclear Information System (INIS)

    Ngotho, E.M.

    2010-01-01

    The need for involvement of Technical and Scientific Support Organisations (TSO) in developing countries intending to launch a nuclear power programme (NPP) cannot be overemphasized. In an International Conference on Topical Issues in Nuclear Installation Safety held in 2008, Mumbai, India, I presented a paper entitled 'Launching a Nuclear Power Programme - a third world country's perspective' - IAEA-CN-158/9. I pointed out some real constraints encountered by a developing country while trying to introduce a nuclear power programme. This was inadequate base infrastructure, financial incapability and lack of skilled manpower. Granted there are areas where the role of TSOs is minimal like in carrying the actual cost of infrastructure but their input in areas of technology, evaluation, assessment and skills development cannot be gainsaid. (author)

  8. NET-ZERO ENERGY BUILDING OPERATOR TRAINING PROGRAM (NZEBOT)

    Energy Technology Data Exchange (ETDEWEB)

    Brizendine, Anthony; Byars, Nan; Sleiti, Ahmad; Gehrig, Bruce; Lu, Na

    2012-12-31

    The primary objective of the Net-Zero Energy Building Operator Training Program (NZEBOT) was to develop certificate level training programs for commercial building owners, managers and operators, principally in the areas of energy / sustainability management. The expected outcome of the project was a multi-faceted mechanism for developing the skill-based competency of building operators, owners, architects/engineers, construction professionals, tenants, brokers and other interested groups in energy efficient building technologies and best practices. The training program draws heavily on DOE supported and developed materials available in the existing literature, as well as existing, modified, and newly developed curricula from the Department of Engineering Technology & Construction Management (ETCM) at the University of North Carolina at Charlotte (UNC-Charlotte). The project goal is to develop a certificate level training curriculum for commercial energy and sustainability managers and building operators that: 1) Increases the skill-based competency of building professionals in energy efficient building technologies and best practices, and 2) Increases the workforce pool of expertise in energy management and conservation techniques. The curriculum developed in this project can subsequently be used to establish a sustainable energy training program that can contribute to the creation of new “green” job opportunities in North Carolina and throughout the Southeast region, and workforce training that leads to overall reductions in commercial building energy consumption. Three energy training / education programs were developed to achieve the stated goal, namely: 1. Building Energy/Sustainability Management (BESM) Certificate Program for Building Managers and Operators (40 hours); 2. Energy Efficient Building Technologies (EEBT) Certificate Program (16 hours); and 3. Energy Efficent Buildings (EEB) Seminar (4 hours). Training Program 1 incorporates the following

  9. Usability requirements for buildings: a case study on primary schools.

    Science.gov (United States)

    Duca, Gabriella

    2012-01-01

    This paper concerns an applied research aimed at applying the concept of usability, as derived form the standard ISO 9241/11, in the filed of building design, namely primary schools. Starting from the concept that space characteristics play a very relevant role in learning performances, the study presented here developed an original methodology for the assessment of effectiveness, efficiency and satisfaction of buildings hosting primary schools, in order to create a school environment better supporting users in their tasks. Research core is the framework of usability requirements and their related markers, indicators and technical specification that has been formulated in order to check compliance of urban area, building, rooms and architectural details with users needs. Therefore, a detailed task analysis of pupils and teacher tasks has been carried out and two questionnaires addressed to a significant users panel have been formulated for satisfaction survey. Lastly, a matrix for an overall reading of gathered data has been set-up and criteria for usability assessment based on that data has been defined. The whole study has been developed within the case study of a primary school in the Naples city centre, whose contents and results are discussed.

  10. Measures taken by the building authorities in order to reduce radiation risks in buildings

    International Nuclear Information System (INIS)

    Tell, Wilhelm

    1980-01-01

    The Swedish radon commission has recommended that the risk of radiation and radon emission from the ground be considered when planning for new settlements, building materials with high radioactivity not be allowed for new buildings, and existing buildings with high levels of radioactivity be traced and improved. Maps of gamma radiation from the ground are being worked out showing areas with levels higher than 30 μR/h. Within such areas buildings should be planned taking the ultimate limits for new buildings into account. Building permits are granted for construction of new structures or extensive renovations if it can be shown that radiation levels within the buildings will be within legal limits: 70 Bq/m 3 for new buildings and 200 Bq/m 3 for existing ones. The radon commission has suggested that buildings with a radon daughter concentration exceeding 400 Bq/m 3 should be found and levels reduced to 200 Bq/m 3

  11. Energy Efficiency Program Administrators and Building Energy Codes

    Science.gov (United States)

    Explore how energy efficiency program administrators have helped advance building energy codes at federal, state, and local levels—using technical, institutional, financial, and other resources—and discusses potential next steps.

  12. Design and Performance of Test Cells as an Energy Evaluation Model of Facades in a Mediterranean Building Area

    Directory of Open Access Journals (Sweden)

    Ángel Luis León-Rodríguez

    2017-11-01

    Full Text Available The current European energy policies have an influence on the need to rehabilitate the housing stock in order to meet the objectives of the European Union. Most of this housing stock was built without any type of energy regulation in adverse technical and economic conditions and thus is now energetically obsolete. The major rehabilitation effort required must be approached through actions based on previous quantitative energy knowledge of the existing buildings in order to guarantee the efficiency of energy-retrofitted solutions. This assessment can be carried out through monitoring dwellings conditioned by use patterns; through simulation programs, which do not usually offer faithful representations of energy conditions; or by using test cells, which allow us to evaluate a controlled indoor environment without the influence of users. The objective of this paper is to present the design and performance of test cells as an experimental method for vertical facade analysis in order to tackle the problem of retrofitting residential buildings in a Mediterranean climate, taking into account energy and environment. With this equipment, efficiency and energy savings, as well as illumination and interior air quality, can be simultaneously and comprehensively evaluated.

  13. American Samoa Initial Technical Assessment Report

    Energy Technology Data Exchange (ETDEWEB)

    Busche, S.; Conrad, M.; Funk, K.; Kandt, A.; McNutt, P.

    2011-09-01

    This document is an initial energy assessment for American Samoa, the first of many steps in developing a comprehensive energy strategy. On March 1, 2010, Assistant Secretary of the Interior Tony Babauta invited governors and their staff from the Interior Insular Areas to meet with senior principals at the National Renewable Energy Laboratory (NREL). Meeting discussions focused on ways to improve energy efficiency and increase the deployment of renewable energy technologies in the U.S. Pacific Territories. In attendance were Governors Felix Camacho (Guam), Benigno Fitial (Commonwealth of the Northern Mariana Islands), and Togiola Tulafono, (American Samoa). This meeting brought together major stakeholders to learn and understand the importance of developing a comprehensive strategic plan for implementing energy efficiency measures and renewable energy technologies. For several decades, dependence on fossil fuels and the burden of high oil prices have been a major concern but never more at the forefront as today. With unstable oil prices, the volatility of fuel supply and the economic instability in American Samoa, energy issues are a high priority. In short, energy security is critical to American Samoa's future economic development and sustainability. Under an interagency agreement, funded by the Department of Interior's Office of Insular Affairs, NREL was tasked to deliver technical assistance to the islands of American Samoa. Technical assistance included conducting an initial technical assessment to define energy consumption and production data, establish an energy consumption baseline, and assist with the development of a strategic plan. The assessment and strategic plan will be used to assist with the transition to a cleaner energy economy. NREL provided an interdisciplinary team to cover each relevant technical area for the initial energy assessments. Experts in the following disciplines traveled to American Samoa for on-island site assessments: (1

  14. TECHNICAL COORDINATION

    CERN Multimedia

    A. Ball

    2010-01-01

    Operational Experience At the end of the first full-year running period of LHC, CMS is established as a reliable, robust and mature experiment. In particular common systems and infrastructure faults accounted for <0.6 % CMS downtime during LHC pp physics. Technical operation throughout the entire year was rather smooth, the main faults requiring UXC access being sub-detector power systems and rack-cooling turbines. All such problems were corrected during scheduled technical stops, in the shadow of tunnel access needed by the LHC, or in negotiated accesses or access extensions. Nevertheless, the number of necessary accesses to the UXC averaged more than one per week and the technical stops were inevitably packed with work packages, typically 30 being executed within a few days, placing a high load on the coordination and area management teams. It is an appropriate moment for CMS Technical Coordination to thank all those in many CERN departments and in the Collaboration, who were involved in CMS techni...

  15. Two innovative solutions based on fibre concrete blocks designed for building substructure

    Science.gov (United States)

    Pazderka, J.; Hájek, P.

    2017-09-01

    Using of fibers in a high-strength concrete allows reduction of the dimensions of small precast concrete elements, which opens up new ways of solution for traditional construction details in buildings. The paper presents two innovative technical solutions for building substructure: The special shaped plinth block from fibre concrete and the fibre concrete elements for new technical solution of ventilated floor. The main advantages of plinth block from fibre concrete blocks (compared with standard plinth solutions) is: easier and faster assembly, higher durability and thanks to the air cavity between the vertical part of the block, the building substructure reduced moisture level of structures under the waterproofing layer and a comprehensive solution to the final surface of building plinth as well as the surface of adjacent terrain. The ventilated floor based on fibre concrete precast blocks is an attractive structural alternative for tackling the problem of increased moisture in masonry in older buildings, lacking a functional waterproof layer in the substructure.

  16. Summary of Tiger Team Assessment and Technical Safety Appraisal recurring concerns in the Maintenance Area

    International Nuclear Information System (INIS)

    1993-01-01

    Tiger Team Assessments and Technical Safety Appraisals (TSA) were reviewed and evaluated for concerns in the Maintenance Area (MA). Two hundred and thirty one (231) maintenance concerns were identified by the Tiger Team Assessments and TSA reports. These recurring concerns appear below. A summary of the Noteworthy Practices that were identified and a compilation of the maintenance concerns for each performance objective that were not considered as recurring are also included. Where the Tiger Team Assessment and TSA identified the operating contractor or facility by name, the concern has been modified to remove the name while retaining the intent of the comment

  17. The research project on technical information basis for aging management in Fukui and Kinki area. Final report

    International Nuclear Information System (INIS)

    Fujimura, Kimiya; Nagayama, Shigeru; Watarumi, Chikae; Toudou, Tsugihiko

    2011-01-01

    The Research Project on Technical Information Basis for Aging Management was initiated in FY2006 by the Nuclear and Industrial Safety Agency (NISA) of the Ministry of Economy, Trade and Industry (METI) as a five-year program effectively, to promote aging management of domestic nuclear power plants. Its main objective was to improve the technical basis on which aging nuclear power plants are regulated. Upon taking part in the technical strategy map for Aging Management and Safe Long Term Operation, the experiences and achievements of the participating organizations were taken into account and the following four topics were chosen. The regional characteristics of the Fukui and Kinki area where 15 nuclear power plants, mainly PWRs, and many nuclear related research institutes and universities are located, were also considered. 1) The improvement of pipe thinning management in nuclear power plants, 2) The development of inspection techniques to monitor the initiation and propagation of defects, 3) The development of a guideline for evaluating weld repair methods, 4) The development of a guideline for evaluating the degradation of main structures. To promote this research project, INSS has established a regional consortium (called the 'Fukui Regional Cluster' in coordination with universities, research institutes, electric utilities and venders in the Fukui and Kinki area. INSS is acting as a coordinator to make contracts, facilitate execution, and compile annual reports. In FY2010, 11 continuing research subjects were proposed for this project and all were accepted. Of these, 5 subjects were related to the first topic (pipe thinning), 4 subjects to the second topic (inspection technique) and 1 subject to each of the other two topics (weld repair and main structures). All the subjects have been completed, fulfilling the requirements and expectations. (author)

  18. Implementation of quality improvement techniques for management and technical processes in the ACRV project

    Science.gov (United States)

    Raiman, Laura B.

    1992-12-01

    Total Quality Management (TQM) is a cooperative form of doing business that relies on the talents of everyone in an organization to continually improve quality and productivity, using teams and an assortment of statistical and measurement tools. The objective of the activities described in this paper was to implement effective improvement tools and techniques in order to build work processes which support good management and technical decisions and actions which are crucial to the success of the ACRV project. The objectives were met by applications in both the technical and management areas. The management applications involved initiating focused continuous improvement projects with widespread team membership. The technical applications involved applying proven statistical tools and techniques to the technical issues associated with the ACRV Project. Specific activities related to the objective included working with a support contractor team to improve support processes, examining processes involved in international activities, a series of tutorials presented to the New Initiatives Office and support contractors, a briefing to NIO managers, and work with the NIO Q+ Team. On the technical side, work included analyzing data from the large-scale W.A.T.E.R. test, landing mode trade analyses, and targeting probability calculations. The results of these efforts will help to develop a disciplined, ongoing process for producing fundamental decisions and actions that shape and guide the ACRV organization .

  19. Implementation of quality improvement techniques for management and technical processes in the ACRV project

    Science.gov (United States)

    Raiman, Laura B.

    1992-01-01

    Total Quality Management (TQM) is a cooperative form of doing business that relies on the talents of everyone in an organization to continually improve quality and productivity, using teams and an assortment of statistical and measurement tools. The objective of the activities described in this paper was to implement effective improvement tools and techniques in order to build work processes which support good management and technical decisions and actions which are crucial to the success of the ACRV project. The objectives were met by applications in both the technical and management areas. The management applications involved initiating focused continuous improvement projects with widespread team membership. The technical applications involved applying proven statistical tools and techniques to the technical issues associated with the ACRV Project. Specific activities related to the objective included working with a support contractor team to improve support processes, examining processes involved in international activities, a series of tutorials presented to the New Initiatives Office and support contractors, a briefing to NIO managers, and work with the NIO Q+ Team. On the technical side, work included analyzing data from the large-scale W.A.T.E.R. test, landing mode trade analyses, and targeting probability calculations. The results of these efforts will help to develop a disciplined, ongoing process for producing fundamental decisions and actions that shape and guide the ACRV organization .

  20. Building energy analysis of Electrical Engineering Building from DesignBuilder tool: calibration and simulations

    Science.gov (United States)

    Cárdenas, J.; Osma, G.; Caicedo, C.; Torres, A.; Sánchez, S.; Ordóñez, G.

    2016-07-01

    This research shows the energy analysis of the Electrical Engineering Building, located on campus of the Industrial University of Santander in Bucaramanga - Colombia. This building is a green pilot for analysing energy saving strategies such as solar pipes, green roof, daylighting, and automation, among others. Energy analysis was performed by means of DesignBuilder software from virtual model of the building. Several variables were analysed such as air temperature, relative humidity, air velocity, daylighting, and energy consumption. According to two criteria, thermal load and energy consumption, critical areas were defined. The calibration and validation process of the virtual model was done obtaining error below 5% in comparison with measured values. The simulations show that the average indoor temperature in the critical areas of the building was 27°C, whilst relative humidity reached values near to 70% per year. The most critical discomfort conditions were found in the area of the greatest concentration of people, which has an average annual temperature of 30°C. Solar pipes can increase 33% daylight levels into the areas located on the upper floors of the building. In the case of the green roofs, the simulated results show that these reduces of nearly 31% of the internal heat gains through the roof, as well as a decrease in energy consumption related to air conditioning of 5% for some areas on the fourth and fifth floor. The estimated energy consumption of the building was 69 283 kWh per year.

  1. Final Scientific and Technical Report State and Regional Biomass Partnerships

    Energy Technology Data Exchange (ETDEWEB)

    Handley, Rick; Stubbs, Anne D.

    2008-12-29

    The Northeast Regional Biomass Program successfully employed a three pronged approach to build the regional capacity, networks, and reliable information needed to advance biomass and bioenergy technologies and markets. The approach included support for state-based, multi-agency biomass working groups; direct technical assistance to states and private developers; and extensive networking and partnership-building activities to share objective information and best practices.

  2. Technical Challenges in Developing Software to Collect Twitter Data

    Directory of Open Access Journals (Sweden)

    Daniel Chudnov

    2014-10-01

    Full Text Available Over the past two years, George Washington University Libraries developed Social Feed Manager (SFM, a Python and Django-based application for collecting social media data from Twitter. Expanding the project from a research prototype to a more widely useful application has presented a number of technical challenges, including changes in the Twitter API, supervision of simultaneous streaming processes, management, storage, and organization of collected data, meeting researcher needs for groups or sets of data, and improving documentation to facilitate other institutions’ installation and use of SFM. This article will describe how the Social Feed Manager project addressed these issues, use of supervisord to manage processes, and other technical decisions made in the course of this project through late summer 2014. This article is targeted towards librarians and archivists who are interested in building collections around web archives and social media data, and have a particular interest in the technical work involved in applying software to the problem of building a sustainable collection management program around these sources.

  3. Emerging Energy-Efficient Technologies in Buildings Technology Characterizations for Energy Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Hadley, SW

    2004-10-11

    The energy use in America's commercial and residential building sectors is large and growing. Over 38 quadrillion Btus (Quads) of primary energy were consumed in 2002, representing 39% of total U.S. energy consumption. While the energy use in buildings is expected to grow to 52 Quads by 2025, a large number of energy-related technologies exist that could curtail this increase. In recent years, improvements in such items as high efficiency refrigerators, compact fluorescent lights, high-SEER air conditioners, and improved building shells have all contributed to reducing energy use. Hundreds of other technology improvements have and will continue to improve the energy use in buildings. While many technologies are well understood and are gradually penetrating the market, more advanced technologies will be introduced in the future. The pace and extent of these advances can be improved through state and federal R&D. This report focuses on the long-term potential for energy-efficiency improvement in buildings. Five promising technologies have been selected for description to give an idea of the wide range of possibilities. They address the major areas of energy use in buildings: space conditioning (33% of building use), water heating (9%), and lighting (16%). Besides describing energy-using technologies (solid-state lighting and geothermal heat pumps), the report also discusses energy-saving building shell improvements (smart roofs) and the integration of multiple energy service technologies (CHP packaged systems and triple function heat pumps) to create synergistic savings. Finally, information technologies that can improve the efficiency of building operations are discussed. The report demonstrates that the United States is not running out of technologies to improve energy efficiency and economic and environmental performance, and will not run out in the future. The five technology areas alone can potentially result in total primary energy savings of between 2 and

  4. Specific features of modern multifunctional high-rise building construction

    Science.gov (United States)

    Manukhina, Lyubov; Samosudova, Natal'ja

    2018-03-01

    The article analyzes the main reasons for the development of high-rise building construction the most important of which-is a limitation of the urban areas and, consequently, the high price of land reserved for construction. New engineering and compositional solutions for the creation of new types of buildings are considered - complex technical designs of a large number of storeys completely meet the new requirements for safety and comfort. Some peculiarities of designing high-rise buildings and searching for optimal architectural and planning solutions are revealed since, with external architectural simplicity, high-rise buildings have complex structural and technological and space-planning solutions. We consider the specific features of a high-rise housing in various countries around the world, including Russia, such as the layout of the multi-storey residential buildings, depending on the climatic characteristics of the regions, assessment of the geological risk of the construction site, the choice of parameters and functional purpose of the sections of the territory of high-rise construction, location of the town-planning object for substantiating the overall dimensions of the building, assessment of changes aeration and engineering and hydrological conditions of the site. A special place in the article on the problems of improvement of the territory, the device of courtyards, landscaping, the device of playing and sports grounds. The main conclusion in the article is the following problem - when developing high-rise housing construction, the development of high-rise housing, and an increase in the population density in the territory of large cities of Russia, necessary to create a comfortable and safe level of residents living and not a decrease, but an improvement in the quality of the urban environment.

  5. Building communities and social potential: Between and beyond organizations and individuals in commercial properties

    International Nuclear Information System (INIS)

    Janda, Kathryn B.

    2014-01-01

    Axon et al., (2012) argue that maximizing the potential for energy efficiency and demand reduction in tenanted commercial properties requires a “building communities” approach. This paper develops and extends Axon et al.′s proposed framework in two ways. First, by extending its applicability from tenanted to owner-occupied properties. Second, by situating it within the literature related to organizational culture, occupant behaviours, and technology adoption. The paper begins with a brief review of the existing research on people, energy and commercial buildings. This literature tends to address either organizational choices, or occupant behavior, but it rarely crosses the analytical boundaries between these two groups. The paper then explores these different levels of analysis within a 3Cs – “concern, capacity, and conditions” – framework, which was developed to describe and distinguish organizational responses to an energy crisis. The combination of the “building communities” and 3Cs frames reveals gaps and grey areas between organizational culture, occupant behaviour, and technology adoption where further conservation opportunities may lie. These understudied areas suggest that there may be “social potential” for change that is between and beyond the frames used by previous research in the field. - Highlights: • We discuss literature on occupant behaviour and organisational factors in commercial buildings. • We introduce two frameworks drawn from previous research: “3Cs” (concern, capacity, and conditions) and “building communities”. • Gaps in the literature call for a “building communities” approach to the 3Cs, which we recommend for near-term research. • We introduce the concept of “social potential” as a counterpoint to technical potential for longer-term research

  6. Resource Conservation and Recovery Act industrial site environmental restoration site characterization plan: Area 23, Building 650 Leachfield

    International Nuclear Information System (INIS)

    1997-03-01

    This plan presents the strategy for the characterization of Corrective Action Unit 94, Area 23, Building 650 Leachfield. It is a land disposal unit, located southeast of Building 650, that was in operation from 1965 to October 1992, with an estimated annual discharge rate of less than 984 liters from designated sinks, floor drains, and emergency decontamination showers in Building 650. The objectives of the planned activities are to: obtain sufficient sample analytical data from which further assessment, remediation, and/or closure strategies may be developed for the site: and obtain sufficient sample analytical data for management of investigation-derived waste (IDW). All references to regulations in this plan are to the versions of the regulations that are current at the time of publication of this plan. The scope of the characterization will include subsurface soil boring (i.e., drilling), in situ sampling of the soil within subsurface soil borings, and sample analysis for both site characterization and waste management purposes

  7. Building capacity for health promotion--a case study from China.

    Science.gov (United States)

    Tang, Kwok-Cho; Nutbeam, Don; Kong, Lingzhi; Wang, Ruotao; Yan, Jun

    2005-09-01

    During the period 1997-2000 a technical assistance project to build capacity for community-based health promotion was implemented in seven cities and one province in China. The technical assistance project formed part of a much larger World Bank supported program to improve disease prevention capabilities in China, commonly known as Health VII. The technical assistance project was funded by the Australian Agency for International Development. It was designed to develop capacity within the Ministry of Health (MOH) and the cities and province in the management of community-based health promotion projects, as well as supporting institutional development and public health policy reform. There are some relatively unique features of this technical assistance which helped shape its implementation and impact. It sought to provide the Chinese MOH and the cities and province with an introduction to comprehensive health promotion strategies, in contrast to the more limited information, education and communication strategies. The project was provided on a continuing basis over 3 years through a single institution, rather than as a series of ad hoc consultancies by individuals. Teaching and learning processes were developmental, leading progressively to a greater degree of local Chinese input and management to ensure sustainability and maintenance of technical support for the project. Based on this experience, this paper presents a model for capacity building projects of this type. It describes the education, training and planning activities that were the key inputs to the project, as well as the limited available evidence on the impact of the project. It describes how the project evolved over time to meet the changing needs of the participants, specifically how the content of the project shifted from a risk-factor orientation to a settings-based focus, and the delivery of the project moved from an expert-led approach to a more participatory, problem based learning approach. In

  8. PRACTICING FACADE RENOVATION OF DANISH BUILDINGS BUILT BETWEEN 1960 AND 1980

    DEFF Research Database (Denmark)

    Hannoudi, Loay Akram; Lauring, Gert Michael; Christensen, Jørgen Erik

    Practising building facade renovation in Denmark, both from the technical and aesthetic points of view, raises many questions that are presented in this paper. These questions are answered and discussed through interviews conducted with seven architectural firms that are involved with façade...... the interviewees. These questions focused on technical, aesthetic, functional, economic and environmental aspects. The results of the interviews show that there are many problems facing these buildings, for example, energy efficiency, durability and indoor climate problems. The process of treating these problems...... on in the interviews. The interviews with the architectural firms were able to answer the questions regarding the building owners’ concerns and showed the way the architectural firms either reacted to these concerns to provide concepts and strategies like external re-insulation, or followed a specific process...

  9. Digital building planning - digital construction; Digitale Gebaeudeplanung - digitales Bauen

    Energy Technology Data Exchange (ETDEWEB)

    Friedrichs, K. [Karlsruhe Univ. (T.H.) (Germany). Fakultaet fuer Architektur

    1995-12-31

    In chapter 3 of the anthology about building control the following aspects are discussed: digital building planning and digital construction, which are characterised by an increasing complexity of planning, buildings, construction technology and construction processes. In this respect the digital-technical scenarios, passive and active objects as well as digital construction are described. (BWI) [Deutsch] Kapitel 3 des Sammelbandes ueber Building Control ist den Themen Digitale Gebaeudeplanung und Digitales Bauen gewidmet, die durch die zunehmende Komplexitaet von Planung, Gebaeuden, Bautechnologien und -prozessen bedingt sind. In diesem Zusammenhang werden folgende Themen angesprochen: Digitale technische Szenarien, passive und aktive Objekte sowie digitales Bauen. (BWI)

  10. Overview of Commercial Building Partnerships in Higher Education

    Energy Technology Data Exchange (ETDEWEB)

    Schatz, Glenn [Energy Efficiency and Renewable Energy (EERE), Washington, DC (United States)

    2013-03-01

    Higher education uses less energy per square foot than most commercial building sectors. However, higher education campuses house energy-intensive laboratories and data centers that may spend more than this average; laboratories, in particular, are disproportionately represented in the higher education sector. The Commercial Building Partnership (CBP), a public/private, cost-shared program sponsored by the U.S. Department of Energy (DOE), paired selected commercial building owners and operators with representatives of DOE, its national laboratories, and private-sector technical experts. These teams explored energy-saving measures across building systems–including some considered too costly or technologically challenging–and used advanced energy modeling to achieve peak whole-building performance. Modeling results were then included in new construction or retrofit designs to achieve significant energy reductions.

  11. CERN Technical Training 2007: IT3T - IT Technical Training Tutorials (Autumn 2007)

    CERN Multimedia

    2007-01-01

    CERN Technical Training and the Internet Services group of the IT department (IT/IS) are jointly organizing a series of free tutorials, addressing some topics of common interest: the IT Technical Training Tutorials (IT3T). The first IT3T series will be offered in October 2007, in French, with the following schedule: IT3T/2007/1 "Introduction to Collaboration Workspaces using SharePoint", October 23rd , 14:30-16:00, Alexandre Lossent IT3T/2007/2 "What is new in Office 2007", October 25th, 14:30-15:30, Emmanuel Ormancey IT3T/2007/3 "Working with Windows Vista at CERN", October 30th, 14:30-15:30, Michal Kwiatek IT3T/2007/4 "Read your mail and more with Outlook 2007", November 1st, 14:30-15:30, Sebastien Dellabella All IT Technical Training Tutorials will take place in the Training Centre Auditorium (building 593, room 11), at 14h30. The tutorials are free of charge, but separate registration to each is required. Participation to any of the tutorials is open: attendance to any ...

  12. Development of safety enhancement technology of containment building

    International Nuclear Information System (INIS)

    Seo, Jeong Moon; Choun, Y. S.; Choi, I. K.

    2002-04-01

    This study consists of four research areas, (1) Seismic safety assessment, (2) Aging assessment of a containment building, (3) Prediction of long-term behavior and analysis of a containment building, (4) Performance verification of a containment building. In the seismic safety assessment area, responses of a containment building were monitored and the analysis method was verified. Also performed are the identification of earthquake characteristics and improvement of the seismic fragility analysis method. In the area of aging assessment of a containment building, we developed aging management code SLMS and database. Aging tests were performed for containment building materials and aging models were developed. Techniques for investigation, detection, and evaluation of aging were developed. In the area of prediction of long-term behavior and analysis of a containment building, we developed a non-linear structural analysis code NUCAS and material models. In the area of performance verification of a containment building, we analyzed the crack behavior of a containment wall and the behavior of the containment under internal pressure. We also improved the ISI methods for prestressed containment

  13. Lost Opportunities in the Buildings Sector: Energy-Efficiency Analysis and Results

    Energy Technology Data Exchange (ETDEWEB)

    Dirks, James A.; Anderson, David M.; Hostick, Donna J.; Belzer, David B.; Cort, Katherine A.

    2008-09-12

    This report summarizes the results and the assumptions used in an analysis of the potential “lost efficiency opportunities” in the buildings sector. These targets of opportunity are those end-uses, applications, practices, and portions of the buildings market which are not currently being addressed, or addressed fully, by the Building Technologies Program (BTP) due to lack of resources. The lost opportunities, while a significant increase in effort and impact in the buildings sector, still represent only a small portion of the full technical potential for energy efficiency in buildings.

  14. Technical Area V (TA-V) transformation project close-out report.

    Energy Technology Data Exchange (ETDEWEB)

    2010-07-01

    Sandia National Laboratories (SNL) Technical Area V (TA-V) has provided unique nuclear experimental environments for decades. The technologies tested in TA-V facilities have furthered the United States Nuclear Weapons program and has contributed to the national energy and homeland security mission. The importance of TA-V working efficiently to produce an attractive and effective platform for experiments should not be underestimated. Throughout its brief history, TA-V has evolved to address multiple and diverse sets of requirements. These requirements evolved over many years; however, the requirements had not been managed nor communicated comprehensively or effectively. A series of programmatic findings over several years of external audits was evidence of this downfall. Today, these same requirements flow down through a new TA-V management system that produces consistently applied and reproducible approaches to work practices. In 2008, the TA-V department managers assessed the state of TA-V services and work activities to understand how to improve customer interfaces, stakeholders perceptions, and workforce efficiencies. The TA-V management team initiated the TA-V Transformation Project after they deemed the pre-June 2008 operational model to be ineffective in managing work and in providing integrated, continuous improvement to TA-V processes. This report summarizes the TA-V Transformation Project goals, activities, and accomplishments.

  15. Energy Gaining Windows for Residental Buildings

    DEFF Research Database (Denmark)

    Kragh, Jesper; Laustsen, Jacob Birck; Svendsen, Svend

    2008-01-01

    This paper presents some of the research done during the last 8 years at the Technical University of Denmark developing improved low-energy window solutions. The focus has been on maximizing the net energy gain of windows for residential buildings. The net energy gain of windows is the solar gain...... minus the heat loss integrated over the heating season. It is assumed that in northern cold climates all of the solar gain during the heating season can be utilized for space heating. Problems with overheating in the summer period must be solved with overhang or moveable solar shading devices. Two...... and longer durability of the window. The glazing in these fiber reinforced polyester windows is both unsealed and sealed triple glazing units. To increase the net energy gain slim frame profiles have been developed to increase the glazing area and thereby the solar gain. The challenge when developing slim...

  16. Technical safety appraisal of buildings 9206 and 9212, Oak Ridge Y-12 plant

    International Nuclear Information System (INIS)

    1989-03-01

    This report covers the results of a Safety Performance Review of the Y-12 Plant conducted during the period July 25 through August 3, 1988. A Safety Performance Review is a followup to assess changes in performance since the 1986 Technical Safety Appraisal (TSA). This review is patterned after a TSA and covered the overall safety performance at Y-12, evaluating progress to date against standards of accepted practice. The review included coverage of actions taken in response to recommendations in the TSA conducted in July--August 1986. Remaining issues were identified through an assessment of safety program deficiencies and their root causes. For each of the 14 safety-related functional areas at the Y-12 Plant, results of this review are listed in Section V. These results include a discussion, conclusions, and any new safety concerns for each program. Appendix A contains a description of the system for categorizing concerns, and the concerns are summarily tabulated in Appendix B for all programs. Appendix C describes the contractor's response and current status of each of the 59 recommendations contained in the 1986 TSA

  17. 3D-PRINTING OF BUILD OBJECTS

    Directory of Open Access Journals (Sweden)

    SAVYTSKYI M. V.

    2016-03-01

    Full Text Available Raising of problem. Today, in all spheres of our life we can constate the permanent search for new, modern methods and technologies that meet the principles of sustainable development. New approaches need to be, on the one hand more effective in terms of conservation of exhaustible resources of our planet, have minimal impact on the environment and on the other hand to ensure a higher quality of the final product. Construction is not exception. One of the new promising technology is the technology of 3D -printing of individual structures and buildings in general. 3Dprinting - is the process of real object recreating on the model of 3D. Unlike conventional printer which prints information on a sheet of paper, 3D-printer allows you to display three-dimensional information, i.e. creates certain physical objects. Currently, 3D-printer finds its application in many areas of production: machine building elements, a variety of layouts, interior elements, various items. But due to the fact that this technology is fairly new, it requires the creation of detailed and accurate technologies, efficient equipment and materials, and development of common vocabulary and regulatory framework in this field. Research Aim. The analysis of existing methods of creating physical objects using 3D-printing and the improvement of technology and equipment for the printing of buildings and structures. Conclusion. 3D-printers building is a new generation of equipment for the construction of buildings, structures, and structural elements. A variety of building printing technics opens up wide range of opportunities in the construction industry. At this stage, printers design allows to create low-rise buildings of different configurations with different mortars. The scientific novelty of this work is to develop proposals to improve the thermal insulation properties of constructed 3D-printing objects and technological equipment. The list of key terms and notions of construction

  18. Advanced transportation system studies, technical area 3. Alternate propulsion subsystem concepts: J-2S restart study

    Science.gov (United States)

    Vilja, John; Levack, Daniel

    1993-04-01

    The objectives were to assess what design changes would be required to remit late production of the J-2S engine for use as a large high energy upper stage engine. The study assessed design changes required to perform per the J-2S model specification, manufacturing changes required due to obsolescence or improvements in state-of-the-practice, availability issues for supplier provided items, and provided cost and schedule estimates for this configuration. The confidence that J-2S production could be reinitiated within reasonable costs and schedules was provided. No significant technical issues were identified in either the producibility study or in the review of previous technical data. Areas of potential cost reduction were identified which could be quantified to a greater extent with further manufacturing planning. The proposed schedule can be met with no foreseeable impacts. The results of the study provided the necessary foundation for the detailed manufacturing and test plans and non-recurring and recurring cost estimates that are needed to complete the effort to reinitiate production of the J-2S engine system.

  19. Clean energy, technical files; Energie propre, les fiches techniques

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    This document is the compilation of the 42 issues of the 'Energie propre - Maitrise de la Demande d'Energie' newsletter published between September 1996 and July 1999 by the regional energy agency of Provence-Alpes-Cote d'Azur region (ARENE). Each issue is a technical file presenting a particular action or study carried out in the framework of the program of mastery of energy demand in Provence-Alpes-Cote d'Azur region (SE France). These studies and actions concern various types of buildings: high schools, residential buildings for old people, office buildings, social buildings, hotels, recreational facilities, and cover all aspects of energy conservation: space heating, lighting systems, ventilation systems, thermal insulation, appliances.. (J.S.)

  20. UK adaptation strategy and technical measures: the impacts of climate change on buildings

    International Nuclear Information System (INIS)

    Sanders, C.H.; Phillipson, M.C.

    2003-01-01

    This paper discusses the importance of climate change for the UK building stock and reviews the predictions of the United Kingdom Climate Impacts Programme 2002 (UKCIP02) scenarios for the future climate that are of relevance to buildings and construction. The possible impacts of these changes on flooding, wind damage, driving rain impact, subsidence and the internal environment of buildings are reviewed and the steps that might be taken to mitigate these impacts discussed. The current response of regulators, standardisation bodies, building owners and the insurance industry to these impacts is examined, and it is shown that each body acts in different ways to different impacts. Some bodies, such as government departments responsible for building regulations and the insurance industry, are taking the possibility of climate change very seriously. However, the uncertainty of future climate predictions, especially as regards wind speed, means that it is not easy to incorporate these issues in formal legislation. The whole culture of standardisation, which is based on well-established data, such as mean climate data over the last 30 years, makes it difficult for British and European Standards, which underpin regulations, to react to the changing climate. (author)

  1. Rise of the build infrastructure

    International Nuclear Information System (INIS)

    Eulisse, Giulio; Muzaffar, Shahzad; Abdurachmanov, David; Mendez, David

    2014-01-01

    CMS Offline Software, CMSSW, is an extremely large software project, with roughly 3 millions lines of code, two hundreds of active developers and two to three active development branches. Given the scale of the problem, both from a technical and a human point of view, being able to keep on track such a large project, bug free, and to deliver builds for different architectures is a challenge in itself. Moreover the challenges posed by the future migration of CMSSW to multithreading also require adapting and improving our QA tools. We present the work done in the last two years in our build and integration infrastructure, particularly in the form of improvements to our build tools, in the simplification and extensibility of our build infrastructure and the new features added to our QA and profiling tools. Finally we present our plans for the future directions for code management and how this reflects on our workflows and the underlying software infrastructure.

  2. 2001 - 2010 Danish design reference year. Reference climate dataset for technical dimensioning in building, construction and other sectors

    Energy Technology Data Exchange (ETDEWEB)

    Grunnet Wang, P.; Scharling, M.; Pagh Nielsen, K.; Kern-Hansen, C. [Danish Meteorological Institute (DMI), Copenhagen (Denmark); Wittchen, K.B. [Aalborg Univ., Danish Building Research Institute (SBi), Copenhagen (Denmark)

    2013-09-15

    This report presents the Danish Design Reference Year based on observed data from 2001 - 2010. In various sectors - i.e. building and construction, energy, etc. - the climate and weather usually plays a part in a given project. The Danish Design Reference Year dataset is a collection of data series for eleven specific parameters, that each represents a typical year in Denmark. The uses of the dataset may vary from simulations to statistical analysis, graphical overviews etc. The Danish land areas have been sectionalised into five to six climatological zones depending on the parameter, each characterized by distinct diurnal and yearly variations. The dataset consists of observed data from one station located within and representing each zone. In addition to the complete Danish Design Reference Year dataset, a subset specifically selected to be used for energy performance calculations for obtaining a building permit is included. (Author)

  3. Technical resource documents and technical handbooks for hazardous-wastes management

    Energy Technology Data Exchange (ETDEWEB)

    Schomaker, N.B.; Bliss, T.M.

    1986-07-01

    The Environmental Protection Agency is preparing a series of Technical Resource Documents (TRD's) and Technical Handbooks to provide best engineering control technology to meet the needs of the Resource Conservation and Recovery Act (RCRA) and the Comprehensive Environmental Response Compensation and Liability Act (CERCLA) respectively. These documents and handbooks are basically compilation of research efforts of the Land Pollution Control Division (LPCD) to date. The specific areas of research being conducted under the RCRA land disposal program relate to laboratory, pilot and field validation studies in cover systems, waste leaching and solidification, liner systems and disposal facility evaluation. The technical handbooks provide the EPA Program Offices and Regions, as well as the states and other interested parties, with the latest information relevant to remedial actions.

  4. Responding to Changes in Building Legislation. Updating Training for the Building Regulations 1985 and Supporting Documents.

    Science.gov (United States)

    Harris, Robert; Phillips, Alan

    A project sought to develop a means of updating and retraining those required to comply with Britain's 1985 Building Regulations, which are substantially different from the previous ones in regard to procedures and technical content. The training needs analysis conducted indicated that the new training should be flexible and use practical and…

  5. Building integration of PCM for natural cooling of buildings

    International Nuclear Information System (INIS)

    Álvarez, Servando; Cabeza, Luisa F.; Ruiz-Pardo, Alvaro; Castell, Albert; Tenorio, José Antonio

    2013-01-01

    Highlights: ► A brief overview of PCM solutions for buildings is provided. ► Some weaknesses of existing PCM solutions for buildings were identified. ► New solutions for PCM integration in buildings are proposed. ► Proposed solutions overcome identified weaknesses of existing solutions. - Abstract: The use of night cooling ventilation in addition of phase change materials (PCMs) is a very powerful strategy for reducing the cooling demand of buildings. Nevertheless, there are inherent drawbacks in the way things have been doing so far: (a) The limited area of contact between PCM and the air; (b) the very low convective heat transfer coefficients which prevents the use of significant amounts of PCM and (c) the very low utilization factor of the cool stored due to the large phase shift between the time when cool is stored and time when it is required by the building. In this paper, we present innovative solutions using PCM to overcome the above situation. Compared with existing solutions, innovative solutions proposed, increase the contact area between PCM and air by a factor of approximately 3.6, increase the convective heat transfer coefficient significantly, and improve the utilization factor due to the inclusion of active control systems which allow the cold stored be actually used when required

  6. Cost Estimates for the Decontamination and Decommissioning of Eight ORNL Buildings

    International Nuclear Information System (INIS)

    Hogan, M.

    2006-01-01

    The U.S. Department of Energy's Oak Ridge National Laboratory (ORNL) contains a number of buildings that are antiquated and no longer used. These buildings historically were used for the production of atomic weapons and often remain contaminated with radioactive materials. Certain costs and risks are associated with the long-term stewardship of the buildings. One way to reduce these liabilities is to eliminate the buildings that are no longer in use and are not expected to be used in the future. Some of these buildings at ORNL are located in an area known as 'Isotope Circle'. From this area, eight buildings that are expected to be decontaminated and decommissioned (D and D) in the next five to ten years were chosen to have cost estimates completed. The specific facilities are Buildings 3030, 3031, 3118, 3032, 3033, 3033 Annex, 3034, and 3093. There are many challenges for estimating the costs to D and D buildings potentially contaminated with radionuclides. Each building is unique, has various types and levels of contamination, and (as in this case) often lacks up-to-date information. Because of these limitations, order-of- magnitude cost estimates for each of the eight ORNL buildings were completed using parametric cost modeling software known as RACER TM (Remedial Action Cost Engineering and Requirements System). This type of cost estimate is useful for screening technical concepts and is used for budgetary planning. For the eight buildings evaluated in this study, the total cost to D and D was estimated to be nearly $6 M. This value includes the direct cost of approximately $3.5 M to complete D and D and $2.5 M in cost markups. Also, assuming the actual project does not begin until the year 2010, this total cost is escalated to almost $6.7 M, which accounts for expected inflation. Although the cost estimates in this study were expected to have a wide range in accuracy, there are various factors that could impact these estimates in a negative or positive fashion

  7. Building Robust Planning and Execution Systems for Virtual Worlds

    National Research Council Canada - National Science Library

    Dini, Don M; van Lent, Michael; Carpenter, Paul; Iyer, Kumar

    2006-01-01

    .... To enable future researchers to build more complete systems, and avoid possible serious system failure, we identify the major technical problems any implementer of such a system would have to face...

  8. Type A Accident Investigation Board report on the January 17, 1996, electrical accident with injury in Technical Area 21 Tritium Science and Fabrication Facility Los Alamos National Laboratory. Final report

    International Nuclear Information System (INIS)

    1996-04-01

    An electrical accident was investigated in which a crafts person received serious injuries as a result of coming into contact with a 13.2 kilovolt (kV) electrical cable in the basement of Building 209 in Technical Area 21 (TA-21-209) in the Tritium Science and Fabrication Facility (TSFF) at Los Alamos National Laboratory (LANL). In conducting its investigation, the Accident Investigation Board used various analytical techniques, including events and causal factor analysis, barrier analysis, change analysis, fault tree analysis, materials analysis, and root cause analysis. The board inspected the accident site, reviewed events surrounding the accident, conducted extensive interviews and document reviews, and performed causation analyses to determine the factors that contributed to the accident, including any management system deficiencies. Relevant management systems and factors that could have contributed to the accident were evaluated in accordance with the guiding principles of safety management identified by the Secretary of Energy in an October 1994 letter to the Defense Nuclear Facilities Safety Board and subsequently to Congress

  9. Type A Accident Investigation Board report on the January 17, 1996, electrical accident with injury in Technical Area 21 Tritium Science and Fabrication Facility Los Alamos National Laboratory. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-04-01

    An electrical accident was investigated in which a crafts person received serious injuries as a result of coming into contact with a 13.2 kilovolt (kV) electrical cable in the basement of Building 209 in Technical Area 21 (TA-21-209) in the Tritium Science and Fabrication Facility (TSFF) at Los Alamos National Laboratory (LANL). In conducting its investigation, the Accident Investigation Board used various analytical techniques, including events and causal factor analysis, barrier analysis, change analysis, fault tree analysis, materials analysis, and root cause analysis. The board inspected the accident site, reviewed events surrounding the accident, conducted extensive interviews and document reviews, and performed causation analyses to determine the factors that contributed to the accident, including any management system deficiencies. Relevant management systems and factors that could have contributed to the accident were evaluated in accordance with the guiding principles of safety management identified by the Secretary of Energy in an October 1994 letter to the Defense Nuclear Facilities Safety Board and subsequently to Congress.

  10. Smart Building Management Systems and Internet of Things

    Directory of Open Access Journals (Sweden)

    Jean Yves Astier

    2017-07-01

    Full Text Available After a brief historical reminder on SCADA systems, we will present the new challenges regarding modern building technical management (BTM systems. We identify the technological evolutions, which allow us to address these new issues, and describe the software and hardware architectures of our Building Management Internet of Things (BMIoT solution. We end by comparing with other older solutions and by a short description of the new business models, our solution allows.

  11. Interim Status Closure Plan Open Burning Treatment Unit Technical Area 16-399 Burn Tray

    Energy Technology Data Exchange (ETDEWEB)

    Vigil-Holterman, Luciana R. [Los Alamos National Laboratory

    2012-05-07

    This closure plan describes the activities necessary to close one of the interim status hazardous waste open burning treatment units at Technical Area (TA) 16 at the Los Alamos National Laboratory (LANL or the Facility), hereinafter referred to as the 'TA-16-399 Burn Tray' or 'the unit'. The information provided in this closure plan addresses the closure requirements specified in the Code of Federal Regulations (CFR), Title 40, Part 265, Subparts G and P for the thermal treatment units operated at the Facility under the Resource Conservation and Recovery Act (RCRA) and the New Mexico Hazardous Waste Act. Closure of the open burning treatment unit will be completed in accordance with Section 4.1 of this closure plan.

  12. BEYOND GREEN BUILDINGS: AN INTEGRATED HOLISTIC DESIGN APPROACH

    Science.gov (United States)

    Technical Challenge: The Urban Sustainable Infrastructure Engineering Program (USIEP) at the University of Colorado at Denver is designing a Sustainable Youth Zone (SYZ) building in a disadvantaged community in Commerce City, CO. The SYZ utilizes a holistic ...

  13. Building with future perspectives - the present challenge; Geaeude mit Zukunft - die Herausforderung heute

    Energy Technology Data Exchange (ETDEWEB)

    Kranz, H.R. [Siemens AG, Karlsruhe (Germany)

    1995-12-31

    In chapter 2 of the anthology about building control the following aspects are discussed: planning of electronic flexibility, requirements to plants and system and operation of technical building systems. (BWI) [Deutsch] Kapitel 2 des Sammelbandes ueber Building Control geht auf golgende Themen ein: Planung der elektronischen Gelenkigkeit, Anforderungen an Anlagen und Systeme sowie Betreiben der Technischen Gebaeudesysteme. (BWI)

  14. Orders- Versus Encounters-Based Image Capture: Implications Pre- and Post-Procedure Workflow, Technical and Build Capabilities, Resulting, Analytics and Revenue Capture: HIMSS-SIIM Collaborative White Paper.

    Science.gov (United States)

    Cram, Dawn; Roth, Christopher J; Towbin, Alexander J

    2016-10-01

    The decision to implement an orders-based versus an encounters-based imaging workflow poses various implications to image capture and storage. The impacts include workflows before and after an imaging procedure, electronic health record build, technical infrastructure, analytics, resulting, and revenue. Orders-based workflows tend to favor some imaging specialties while others require an encounters-based approach. The intent of this HIMSS-SIIM white paper is to offer lessons learned from early adopting institutions to physician champions and informatics leadership developing strategic planning and operational rollouts for specialties capturing clinical multimedia.

  15. Surfaces of Building Practice

    OpenAIRE

    Surynková, Petra

    2009-01-01

    My diploma thesis Surfaces of Building Practice deals with the basic properties of surfaces, their mathematical description, categorization, and application in technical practice. Each studied surface is defined and its process of construction and parametrical description is listed. The thesis studies selected types of surfaces in details - these surfaces include surfaces of revolution, ruled surfaces, screw surfaces, and translational surfaces. An application of each studied surfaces is show...

  16. An evaluation of the effectiveness of the UK programme to protect new buildings in radon affected areas

    International Nuclear Information System (INIS)

    Denman, A.R.; Fraser, J.; Phillips, P.S.

    2000-01-01

    The discovery of areas in the UK with significant indoor radon levels prompted the Building Research Establishment in 1992 to publish guidance (1) specifying protection measures, enforced by law, when building new houses in radon Affected Areas. In high risk areas, with over 10% of existing houses above the 200 Bq m -3 Action Level, primary protection in the form of a radon-proof membrane is required, as well as secondary protection in the form of a sump capable of being fitted with a low cost pump. In lower risk areas with 3 to 10% of houses above the Action Level only secondary protection is specified. This latter requirement reduces the cost of providing radon remediation to around pound 150 for the fan, rather than an average of pound 750 for providing a sump and fitting a fan, but requires measurement of the radon level to judge whether remediation is required. Northamptonshire, with 6.3% of houses above the Action Level, has areas of both high and lower risk. There has been considerable influx of population in recent years, with 12,200 new houses built since 1993. In high risk areas in Northamptonshire, the collective dose reduction of primary protection has been calculated and has now reached 23 man-sieverts per year has been avoided in the total of 7,900 houses built since 1993. Using current NRPB risk estimates this is equivalent to 0.8 lung cancers avoided each year. This is similar to that achieved by the remediation programme in existing housing, although the potential saving in existing housing is much greater if more householders can be encouraged to carry out remediation (2). In addition, two new housing estates in the lower risk area have been assessed by issuing 6-day etched track detectors to householders, and using a questionnaire to assess their knowledge of radon. Two detectors were used, one in the living area and bedroom, and results were combined using the NRPB protocol to give a weighted seasonally corrected average radon level. In one

  17. Energy efficiency of high-rise buildings

    Science.gov (United States)

    Zhigulina, Anna Yu.; Ponomarenko, Alla M.

    2018-03-01

    The article is devoted to analysis of tendencies and advanced technologies in the field of energy supply and energy efficiency of tall buildings, to the history of the emergence of the concept of "efficiency" and its current interpretation. Also the article show the difference of evaluation criteria of the leading rating systems LEED and BREEAM. Authors reviewed the latest technologies applied in the construction of energy efficient buildings. Methodological approach to the design of tall buildings taking into account energy efficiency needs to include the primary energy saving; to seek the possibility of production and accumulation of alternative electric energy by converting energy from the sun and wind with the help of special technical devices; the application of regenerative technologies.

  18. Lighting and shading of PV systems in buildings: Visualisation, calculation of shading losses, optimisation; Licht und Schatten auf ``PV in Gebaeuden``: Visualisierung, Ertragsprognose, Optimierung

    Energy Technology Data Exchange (ETDEWEB)

    Reise, C. [Fraunhofer-Inst. fuer Solare Energiesysteme, Freiburg (Germany). Abt. fuer Photovoltaische Systeme und Messtechnik

    1998-02-01

    Integrating photovoltaic generators in buildings often requires a specific assessment of the local solar resource. In built-up areas, partial shading of the generator area sometimes cannot be avoided. A combination of the simulation tools RADIANCE and INSEL provides both a perfect visualization and an accurate estimation of shading losses, on the basis of the same numerical model of the building. Thus, simulation techniques help to meet both the aesthetical and the technical requirements of a building construction. (orig.) [Deutsch] Die Integration von photovoltaischen Generatoren in Gebaeude erfordert oft eine besondere Bewertung der lokalen Einstrahlungsverhaeltnisse. In einer dicht bebauten Umgebung kann eine zeitweise Teilverschattung der Generatorflaechen oft nicht vermieden werden. Eine Kombination der Simulationsprogramme RADIANCE und INSEL ermoeglicht die architektonisch vollwertige Visualisierung und Durchfuehrung einer praezisen (Minder-)Ertragsprognose fuer gebaeudeintegrierte Photovoltaik auf der Basis desselben numerischen Gebaeudemodells. Die detaillierte Simulation traegt dazu bei, aesthetische und technische Anforderungen an die Gebaeudekonstruktion in Einklang zu bringen. (orig.)

  19. Technical Cooperation report for 2006. Report by the Director General

    International Nuclear Information System (INIS)

    2007-07-01

    The period under review was one of considerable satisfaction for the TC programme. New resources reached a record high of $101.0 million with $76.8 million for the Technical Cooperation Fund, $22.3 million in extra budgetary resources and $1.9 million in in-kind contributions. Net new obligations during the year were $104.5 million, which represented an increase of more than 30% over 2005. The year 2007 marks the 50th anniversary of the IAEA and provides an opportunity to look back on the history of TC activities. In its early days, the technical assistance programme, as it was then called, was modest: in 1960 the Board of Governors approved 28 projects in 16 Member States. Over time, the demand for Agency assistance and expertise has grown steadily: the TC programme that was approved by the Board of Governors in 2006 featured more than 780 projects in 115 Member States. In recent years, there has been shift in attitudes towards nuclear power in a number of countries around the world. This trend can be traced to a fast growing global energy demand, increased emphasis on energy security and a heightened awareness of the risks of climate change. This has led to a rising number of requests for energy planning projects, which may include nuclear power as an option. In 2006, the Secretariat developed and finalized the TC programme for the 2007-2008 biennium using the Programme Cycle Management Framework in close collaboration with national authorities. The PCMF is supported by a dedicated website, which facilitates collaboration among stakeholders in the Member States and the Secretariat. In line with the TC Strategy, the Secretariat concentrated on building partnerships with national, regional and international development organizations. This includes, inter alia, support for the New Partnership for Africa's Development and partnership with the United Nations Environment Programme. A new challenge which could have an impact on the TC programme in the areas of resource

  20. Technical Cooperation Report for 2006. Report by the Director General

    International Nuclear Information System (INIS)

    2007-07-01

    The period under review was one of considerable satisfaction for the TC programme. New resources reached a record high of $101.0 million with $76.8 million for the Technical Cooperation Fund, $22.3 million in extra budgetary resources and $1.9 million in in-kind contributions. Net new obligations during the year were $104.5 million, which represented an increase of more than 30% over 2005. The year 2007 marks the 50th anniversary of the IAEA and provides an opportunity to look back on the history of TC activities. In its early days, the technical assistance programme, as it was then called, was modest: in 1960 the Board of Governors approved 28 projects in 16 Member States. Over time, the demand for Agency assistance and expertise has grown steadily: the TC programme that was approved by the Board of Governors in 2006 featured more than 780 projects in 115 Member States. In recent years, there has been shift in attitudes towards nuclear power in a number of countries around the world. This trend can be traced to a fast growing global energy demand, increased emphasis on energy security and a heightened awareness of the risks of climate change. This has led to a rising number of requests for energy planning projects, which may include nuclear power as an option. In 2006, the Secretariat developed and finalized the TC programme for the 2007-2008 biennium using the Programme Cycle Management Framework in close collaboration with national authorities. The PCMF is supported by a dedicated website, which facilitates collaboration among stakeholders in the Member States and the Secretariat. In line with the TC Strategy, the Secretariat concentrated on building partnerships with national, regional and international development organizations. This includes, inter alia, support for the New Partnership for Africa's Development and partnership with the United Nations Environment Programme. A new challenge which could have an impact on the TC programme in the areas of resource

  1. Technical Cooperation Report for 2006. Report by the Director General

    International Nuclear Information System (INIS)

    2007-07-01

    The period under review was one of considerable satisfaction for the TC programme. New resources reached a record high of $101.0 million with $76.8 million for the Technical Cooperation Fund, $22.3 million in extra budgetary resources and $1.9 million in in-kind contributions. Net new obligations during the year were $104.5 million, which represented an increase of more than 30% over 2005. The year 2007 marks the 50th anniversary of the IAEA and provides an opportunity to look back on the history of TC activities. In its early days, the technical assistance programme, as it was then called, was modest: in 1960 the Board of Governors approved 28 projects in 16 Member States. Over time, the demand for Agency assistance and expertise has grown steadily: the TC programme that was approved by the Board of Governors in 2006 featured more than 780 projects in 115 Member States. In recent years, there has been shift in attitudes towards nuclear power in a number of countries around the world. This trend can be traced to a fast growing global energy demand, increased emphasis on energy security and a heightened awareness of the risks of climate change. This has led to a rising number of requests for energy planning projects, which may include nuclear power as an option. In 2006, the Secretariat developed and finalized the TC programme for the 2007-2008 biennium using the Programme Cycle Management Framework in close collaboration with national authorities. The PCMF is supported by a dedicated website, which facilitates collaboration among stakeholders in the Member States and the Secretariat. In line with the TC Strategy, the Secretariat concentrated on building partnerships with national, regional and international development organizations. This includes, inter alia, support for the New Partnership for Africa's Development and partnership with the United Nations Environment Programme. A new challenge which could have an impact on the TC programme in the areas of resource

  2. Technical Cooperation report for 2006. Report by the Director General

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-15

    The period under review was one of considerable satisfaction for the TC programme. New resources reached a record high of $101.0 million with $76.8 million for the Technical Cooperation Fund, $22.3 million in extra budgetary resources and $1.9 million in in-kind contributions. Net new obligations during the year were $104.5 million, which represented an increase of more than 30% over 2005. The year 2007 marks the 50th anniversary of the IAEA and provides an opportunity to look back on the history of TC activities. In its early days, the technical assistance programme, as it was then called, was modest: in 1960 the Board of Governors approved 28 projects in 16 Member States. Over time, the demand for Agency assistance and expertise has grown steadily: the TC programme that was approved by the Board of Governors in 2006 featured more than 780 projects in 115 Member States. In recent years, there has been shift in attitudes towards nuclear power in a number of countries around the world. This trend can be traced to a fast growing global energy demand, increased emphasis on energy security and a heightened awareness of the risks of climate change. This has led to a rising number of requests for energy planning projects, which may include nuclear power as an option. In 2006, the Secretariat developed and finalized the TC programme for the 2007-2008 biennium using the Programme Cycle Management Framework in close collaboration with national authorities. The PCMF is supported by a dedicated website, which facilitates collaboration among stakeholders in the Member States and the Secretariat. In line with the TC Strategy, the Secretariat concentrated on building partnerships with national, regional and international development organizations. This includes, inter alia, support for the New Partnership for Africa's Development and partnership with the United Nations Environment Programme. A new challenge which could have an impact on the TC programme in the areas of resource

  3. Technical Cooperation Report for 2006. Report by the Director General

    International Nuclear Information System (INIS)

    2007-07-01

    The period under review was one of considerable satisfaction for the TC programme. New resources reached a record high of $101.0 million with $76.8 million for the Technical Cooperation Fund, $22.3 million in extra budgetary resources and $1.9 million in in-kind contributions. Net new obligations during the year were $104.5 million, which represented an increase of more than 30% over 2005. The year 2007 marks the 50th anniversary of the IAEA and provides an opportunity to look back on the history of TC activities. In its early days, the technical assistance programme, as it was then called, was modest: in 1960 the Board of Governors approved 28 projects in 16 Member States. Over time, the demand for Agency assistance and expertise has grown steadily: the TC programme that was approved by the Board of Governors in 2006 featured more than 780 projects in 115 Member States. In recent years, there has been shift in attitudes towards nuclear power in a number of countries around the world. This trend can be traced to a fast growing global energy demand, increased emphasis on energy security and a heightened awareness of the risks of climate change. This has led to a rising number of requests for energy planning projects, which may include nuclear power as an option. In 2006, the Secretariat developed and finalized the TC programme for the 2007-2008 biennium using the Programme Cycle Management Framework in close collaboration with national authorities. The PCMF is supported by a dedicated website, which facilitates collaboration among stakeholders in the Member States and the Secretariat. In line with the TC Strategy, the Secretariat concentrated on building partnerships with national, regional and international development organizations. This includes, inter alia, support for the New Partnership for Africa's Development and partnership with the United Nations Environment Programme. A new challenge which could have an impact on the TC programme in the areas of resource

  4. Technical Cooperation Report for 2006. Report by the Director General

    International Nuclear Information System (INIS)

    2007-07-01

    The period under review was one of considerable satisfaction for the TC programme. New resources reached a record high of $101.0 million with $76.8 million for the Technical Cooperation Fund, $22.3 million in extra budgetary resources and $1.9 million in in-kind contributions. Net new obligations during the year were $104.5 million, which represented an increase of more than 30% over 2005. The year 2007 marks the 50th anniversary of the IAEA and provides an opportunity to look back on the history of TC activities. In its early days, the technical assistance programme, as it was then called, was modest: in 1960 the Board of Governors approved 28 projects in 16 Member States. Over time, the demand for Agency assistance and expertise has grown steadily: the TC programme that was approved by the Board of Governors in 2006 featured more than 780 projects in 115 Member States. In recent years, there has been shift in attitudes towards nuclear power in a number of countries around the world. This trend can be traced to a fast growing global energy demand, increased emphasis on energy security and a heightened awareness of the risks of climate change. This has led to a rising number of requests for energy planning projects, which may include nuclear power as an option. In 2006, the Secretariat developed and finalized the TC programme for the 2007-2008 biennium using the Programme Cycle Management Framework in close collaboration with national authorities. The PCMF is supported by a dedicated website, which facilitates collaboration among stakeholders in the Member States and the Secretariat. In line with the TC Strategy, the Secretariat concentrated on building partnerships with national, regional and international development organizations. This includes, inter alia, support for the New Partnership for Africa's Development and partnership with the United Nations Environment Programme. A new challenge which could have an impact on the TC programme in the areas of resource

  5. Technical Cooperation Report for 2014. Report by the Director General

    International Nuclear Information System (INIS)

    2015-06-01

    The Technical Cooperation Report for 2014 is set out in three parts: A — Strengthening the Agency’s Technical Cooperation Activities; B — TC Programme Resources and Delivery; and C — Programme Activities and Achievements in 2014: Regional Overview. Annex 1 describes examples of project activities and achievements in specific thematic areas, and Annex 2 describes the activities of the Programme of Action for Cancer Therapy. Annex 3 presents the TC programme Fields of Activity, grouped for reporting purposes. Part A is composed of two sections. Part A.1 provides an overview of the Agency’s technical cooperation (TC) activities in 2014. The first section is devoted to the global development context, and highlights the importance of the post-2015 development agenda, and the value of the Sustainable Development Goals’ programmatic framework for the Agency’s technical cooperation activities. The section then describes how the programme is tailored to respond to the specific needs and priorities of each region, focusing on efforts to develop human resources and build capacities in the peaceful application of nuclear science and technology, including through postgraduate training courses, assistance in drafting legislation, distance learning initiatives and technical cooperation among developing countries. The section also presents a snapshot of TC projects that address radioactive waste management, reflecting the topic of the 2014 Scientific Forum. Part A.2 focuses on efforts to build a more efficient and effective TC programme, in particular on efforts to strengthen the Country Programme Framework template. The section reviews progress made in 2014 in establishing and operationalizing partnerships with the United Nations and other relevant international and regional organizations. This section closes with an overview of actions undertaken in 2014 to continually improve the TC programme, notably through training in the Logical Framework Approach, and

  6. DESIGNING AND BUILDING EXERCISE MODEL OF TECHNICAL ENGLISH VOCABULARIES USING CALL (COMPUTER ASSISTED LANGUAGE LEARNING

    Directory of Open Access Journals (Sweden)

    Yogi Widiawati

    2017-11-01

    Full Text Available The research is aimed to assist and facilitate the students of Electrical and Electronics Department of Politeknik Negeri Jakarta (State Polytechnics of Jakarta, Indonesia, in learning technical English vocabulary. As technical students, they study ESP (English for Specific Purposes and they find some obstacles in memorizing technical vocabularies which are very important in order to read and understand manual books for laboratory and workshop. Some English technical vocabularies among others are “generate”, “pile”, “bench”, et cetera. The research outcome is software which will be beneficial for technical students, especially electrical and electronics students. This software can be used to practice their vocabulary skills, so they will be more skillful and knowledgeable. This software is designed by using the program of Rapid E-Learning Suite Version 5.2 and Flash CS3. The software practice contains some exercises on reading text and reading comprehension questions and presented with the multiple answers. This software is handy and flexible because students can bring it anywhere and be studied anytime. It is handy because this software is put and saved in CD (compact disc, so the students can take it with them anywhere and anytime they want to learn. In other words, they have flexibility to learn and practice English Technical Vocabularies. As a result, the students are found one of the ways to overcome their problems of memorizing vocabularies. The product is a kind of software which is easily used and portable so that the students can use the software anywhere and anytime. It consists of 3 (three sections of exercises. At the end of each exercise, the students are evaluated automatically by looking at the scoring system. These will encourage them to get good score by repeating it again and again. So the technical words are not problem for them. Furthermore, the students can practice technical English vocabulary both at home and

  7. Analysis of building deformation in landslide area using multisensor PSInSAR™ technique.

    Science.gov (United States)

    Ciampalini, Andrea; Bardi, Federica; Bianchini, Silvia; Frodella, William; Del Ventisette, Chiara; Moretti, Sandro; Casagli, Nicola

    2014-12-01

    Buildings are sensitive to movements caused by ground deformation. The mapping both of spatial and temporal distribution, and of the degree of building damages represents a useful tool in order to understand the landslide evolution, magnitude and stress distribution. The high spatial resolution of space-borne SAR interferometry can be used to monitor displacements related to building deformations. In particular, PSInSAR technique is used to map and monitor ground deformation with millimeter accuracy. The usefulness of the above mentioned methods was evaluated in San Fratello municipality (Sicily, Italy), which was historically affected by landslides: the most recent one occurred on 14th February 2010. PSInSAR data collected by ERS 1/2, ENVISAT, RADARSAT-1 were used to study the building deformation velocities before the 2010 landslide. The X-band sensors COSMO-SkyMed and TerraSAR-X were used in order to monitor the building deformation after this event. During 2013, after accurate field inspection on buildings and structures, damage assessment map of San Fratello were created and then compared to the building deformation velocity maps. The most interesting results were obtained by the comparison between the building deformation velocity map obtained through COSMO-SkyMed and the damage assessment map. This approach can be profitably used by local and Civil Protection Authorities to manage the post-event phase and evaluate the residual risks.

  8. Suitability assessment of building energy saving technologies for office buildings in cold areas of China based on an assessment framework

    International Nuclear Information System (INIS)

    Geng, Geng; Wang, Zhaoxia; Zhao, Jing; Zhu, Neng

    2015-01-01

    Highlights: • An assessment method considering economy, environment and technology is proposed. • Office buildings are classified into 3 types and weights are calculated respectively. • BESTs were summed up as 3 suitability levels. • Recommendations are proposed for adopting in design stage. - Abstract: Blind application and extensive copy of building energy saving technologies have been found very common through investigation in China. Emphases should be put on the suitability assessment when selecting and optimizing building energy saving technologies. This paper created an assessment method, namely an assessment framework to assess the suitability level of building energy saving technologies from a holistic point of view. Fuzzy analytic hierarchy process was adopted. 3 factors and 8 sub-factors were included in the framework. The office buildings were classified into 3 types to calculate weights of factors and sub-factors. The assessment framework was established for each type of office buildings. 20 energy saving technologies from surveyed cases was selected as case study. Ranks of suitability level of the assessment objects were obtained for each type of office buildings. The assessment results could be referred when selecting building energy saving technologies in the design stage

  9. 10 CFR 434.520 - Speculative buildings.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Speculative buildings. 434.520 Section 434.520 Energy... RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.520 Speculative buildings. 520... for the lighting power provided for the common areas of the building. 520.4Documentation for future...

  10. Knowledge transfer from building operation to construction

    DEFF Research Database (Denmark)

    Jensen, Per Anker; Chatzilazarou, Stamatia

    2017-01-01

    Purpose: To investigate how knowledge that derives from operation and maintenance of buildings can be stored and transferred in order to be reused in a future building project? Design/methodology/approach: The paper is theoretically based on knowledge management with a particular focus...... on interdepartmental knowledge transfer between departments responsible for operation and management and departments responsible for building projects in organisations with large and fast changing building portfolios. The paper includes a case study of the FM organisation of the Technical University of Denmark...... with data collection mainly by interviews with managers and staff in the relevant departments in this organisation. Findings: The case organisation seems to be aware of the importance of sharing and transferring their organisational knowledge. Over the last five years, the organisation has developed...

  11. Environmental effect of structural solutions and building materials to a building

    International Nuclear Information System (INIS)

    Haapio, Appu; Viitaniemi, Pertti

    2008-01-01

    The field of building environmental assessment tools has become a popular research area over the past decade. However, how the service life of a building affects the results of the environmental assessment of a building has not been emphasised previously. The aim of this study is to analyse how different structural solutions and building materials affect the results of the environmental assessment of a whole building over the building's life cycle. Furthermore, how the length of the building's service life affects the results is analysed. The environmental assessments of 78 single-family houses were calculated for this study. The buildings have different wall insulations, claddings, window frames, and roof materials, and the length of the service life varies from 60 years up to 160 years. The current situation and the future of the environmental assessment of buildings are discussed. In addition, topics for further research are suggested; for example, how workmanship affects the service life and the environmental impact of a building should be studied

  12. Solvothermal conversion of technical lignins over NiMo catalysts

    DEFF Research Database (Denmark)

    Ghafarnejad Parto, Soheila; Christensen, Jakob Munkholt; Pedersen, Lars Saaby

    Scope: Lignin, cellulose and hemicellulose are the main constituents of plants cell walls. Lignin is an aromatic rich compound, composed of phenolic building blocks. Depending on the method used for isolation of lignin from cellulose and hemicellulose, several types of technical lignin are availa......Scope: Lignin, cellulose and hemicellulose are the main constituents of plants cell walls. Lignin is an aromatic rich compound, composed of phenolic building blocks. Depending on the method used for isolation of lignin from cellulose and hemicellulose, several types of technical lignin...... of the range of available technical lignins. In this work, catalytic conversion of different types of lignin using an alumina supported NiMo catalyst (provided by Haldor Topsøe A/S) is conducted in ethanol at 310 ˚C with initial hydrogen pressure of 25 barg. The reaction time was set to 3 hours. Proton......, attributed as ‘bio-oil’. GC-MS-FID analysis was used for identification and quantification of the bio-oil and ethanol rich light fraction. The molecular weight of the oil fraction was determined by size exclusion chromatography (SEC). Elemental analysis (Eurovector EuroEA3000) was conducted for measuring...

  13. Technical challenges of superconductivity and cryogenics in pursuing TESLA-TTF

    International Nuclear Information System (INIS)

    Shu, Quan-Sheng

    1996-01-01

    TESLA (TeV Energy Superconducting Linear Accelerator) Collaboration is an international R ampersand D effort towards the development of an e + e - linear collider with 500 GeV center of mass by means of 20 km active superconducting accelerating structures at a frequency of 1.3 GHz. The ultimate challenges faced by the TESLA project are (1) to raise operational accelerating gradients to 25 MV/m from current world level of 5-10 MV/m, and (2) to reduce construction costs (cryomodules, klystrons, etc.) down to $2,000/MV from now about $40,000/MV. The TESLA Collaboration is building a prototype TESLA test facility (TTF) of a 500 MeV superconducting linear accelerator to establish the technical basis. TTF is presently under construction and will be commissioned at DESY in 1997, through the joint efforts of 24 laboratories from 8 countries. Significant progress has been made in reaching the high accelerating gradient of 25 MV/m in superconducting cavities, developing cryomodules and constructing TTF infrastructure, etc. This paper will briefly discuss the challenges being faced and review the progress achieved in the technical area of superconductivity and cryogenics by the TESLA Collaboration

  14. Magnetic fusion energy plasma interactive and high heat flux components. Volume II. Technical assessment of the critical issues and problem areas in high heat flux materials and component development

    International Nuclear Information System (INIS)

    Abdou, M.A.; Boyd, R.D.; Easor, J.R.

    1984-06-01

    A technical assessment of the critical issues and problem areas for high heat flux materials and components (HHFMC) in magnetic fusion devices shows these problems to be of critical importance for the successful operation of near-term fusion experiments and for the feasibility and attractiveness of long-term fusion reactors. A number of subgroups were formed to assess the critical HHFMC issues along the following major lines: (1) source conditions, (2) systems integration, (3) materials and processes, (4) thermal hydraulics, (5) thermomechanical response, (6) electromagnetic response, (7) instrumentation and control, and (8) test facilities. The details of the technical assessment are presented in eight chapters. The primary technical issues and needs for each area are highlighted

  15. Magnetic fusion energy plasma interactive and high heat flux components. Volume II. Technical assessment of the critical issues and problem areas in high heat flux materials and component development

    Energy Technology Data Exchange (ETDEWEB)

    Abdou, M.A.; Boyd, R.D.; Easor, J.R.; Gauster, W.B.; Gordon, J.D.; Mattas, R.F.; Morgan, G.D.; Ulrickson, M.A,; Watson, R.D.; Wolfer, W.G,

    1984-06-01

    A technical assessment of the critical issues and problem areas for high heat flux materials and components (HHFMC) in magnetic fusion devices shows these problems to be of critical importance for the successful operation of near-term fusion experiments and for the feasibility and attractiveness of long-term fusion reactors. A number of subgroups were formed to assess the critical HHFMC issues along the following major lines: (1) source conditions, (2) systems integration, (3) materials and processes, (4) thermal hydraulics, (5) thermomechanical response, (6) electromagnetic response, (7) instrumentation and control, and (8) test facilities. The details of the technical assessment are presented in eight chapters. The primary technical issues and needs for each area are highlighted.

  16. Clean energy, technical files; Energie propre, les fiches techniques

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    This document is the compilation of the 42 issues of the 'Energie propre - Maitrise de la Demande d'Energie' newsletter published between September 1996 and July 1999 by the regional energy agency of Provence-Alpes-Cote d'Azur region (ARENE). Each issue is a technical file presenting a particular action or study carried out in the framework of the program of mastery of energy demand in Provence-Alpes-Cote d'Azur region (SE France). These studies and actions concern various types of buildings: high schools, residential buildings for old people, office buildings, social buildings, hotels, recreational facilities, and cover all aspects of energy conservation: space heating, lighting systems, ventilation systems, thermal insulation, appliances.. (J.S.)

  17. Technical area status report for chemical/physical treatment

    International Nuclear Information System (INIS)

    Brown, C.H. Jr.; Schwinkendorf, W.E.

    1993-08-01

    These Appendices describe various technologies that may be applicable to the Mixed Waste Treatment Plant (MWTP) Chemical/Physical Treatment System (CPTS). These technologies were identified by the CPTS Technical Support Group (TSG) as potentially applicable to a variety of separation, volume reduction, and decontamination requirements. The purpose was to identify all available and developing technologies, and their characteristics, for subsequent evaluation for specific requirements identified for the CPTS. However, the technologies described herein are not necessarily all inclusive, nor are they necessarily all applicable

  18. Canister storage building trade study. Final report

    International Nuclear Information System (INIS)

    Swenson, C.E.

    1995-05-01

    This study was performed to evaluate the impact of several technical issues related to the usage of the Canister Storage Building (CSB) to safely stage and store N-Reactor spent fuel currently located at K-Basin 100KW and 100KE. Each technical issue formed the basis for an individual trade study used to develop the ROM cost and schedule estimates. The study used concept 2D from the Fluor prepared ''Staging and Storage Facility (SSF) Feasibility Report'' as the basis for development of the individual trade studies

  19. Canister storage building trade study. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Swenson, C.E. [Westinghouse Hanford Co., Richland, WA (United States)

    1995-05-01

    This study was performed to evaluate the impact of several technical issues related to the usage of the Canister Storage Building (CSB) to safely stage and store N-Reactor spent fuel currently located at K-Basin 100KW and 100KE. Each technical issue formed the basis for an individual trade study used to develop the ROM cost and schedule estimates. The study used concept 2D from the Fluor prepared ``Staging and Storage Facility (SSF) Feasibility Report`` as the basis for development of the individual trade studies.

  20. Special Analysis: Disposal Plan for Pit 38 at Technical Area 54, Area G

    Energy Technology Data Exchange (ETDEWEB)

    French, Sean B. [Los Alamos National Laboratory; Shuman, Rob [URS Coporation

    2012-06-26

    Los Alamos National Laboratory (LANL) generates radioactive waste as a result of various activities. Operational waste is generated from a wide variety of research and development activities including nuclear weapons development, energy production, and medical research; environmental restoration (ER), and decontamination and decommissioning (D&D) waste is generated as contaminated sites and facilities at LANL undergo cleanup or remediation. The majority of this waste is low-level radioactive waste (LLW) and is disposed of at the Technical Area 54 (TA-54), Area G disposal facility. U.S. Department of Energy (DOE) Order 435.1 (DOE, 2001) requires that radioactive waste be managed in a manner that protects public health and safety, and the environment. To comply with this order, DOE field sites must prepare site-specific radiological performance assessments for LLW disposal facilities that accept waste after September 26, 1988. Furthermore, sites are required to conduct composite analyses that account for the cumulative impacts of all waste that has been (or will be) disposed of at the facilities and other sources of radioactive material that may interact with the facilities. Revision 4 of the Area G performance assessment and composite analysis was issued in 2008 (LANL, 2008). These analyses estimate rates of radionuclide release from the waste disposed of at the facility, simulate the movement of radionuclides through the environment, and project potential radiation doses to humans for several on- and off-site exposure scenarios. The assessments are based on existing site and disposal facility data, and on assumptions about future rates and methods of waste disposal. The Area G disposal facility consists of Material Disposal Area (MDA) G and the Zone 4 expansion area. To date, disposal operations have been confined to MDA G and are scheduled to continue in that region until MDA G undergoes final closure at the end of 2013. Given its impending closure, efforts have

  1. Special Analysis: Disposal Plan for Pit 38 at Technical Area 54, Area G

    International Nuclear Information System (INIS)

    French, Sean B.; Shuman, Rob

    2012-01-01

    Los Alamos National Laboratory (LANL) generates radioactive waste as a result of various activities. Operational waste is generated from a wide variety of research and development activities including nuclear weapons development, energy production, and medical research; environmental restoration (ER), and decontamination and decommissioning (D and D) waste is generated as contaminated sites and facilities at LANL undergo cleanup or remediation. The majority of this waste is low-level radioactive waste (LLW) and is disposed of at the Technical Area 54 (TA-54), Area G disposal facility. U.S. Department of Energy (DOE) Order 435.1 (DOE, 2001) requires that radioactive waste be managed in a manner that protects public health and safety, and the environment. To comply with this order, DOE field sites must prepare site-specific radiological performance assessments for LLW disposal facilities that accept waste after September 26, 1988. Furthermore, sites are required to conduct composite analyses that account for the cumulative impacts of all waste that has been (or will be) disposed of at the facilities and other sources of radioactive material that may interact with the facilities. Revision 4 of the Area G performance assessment and composite analysis was issued in 2008 (LANL, 2008). These analyses estimate rates of radionuclide release from the waste disposed of at the facility, simulate the movement of radionuclides through the environment, and project potential radiation doses to humans for several on- and off-site exposure scenarios. The assessments are based on existing site and disposal facility data, and on assumptions about future rates and methods of waste disposal. The Area G disposal facility consists of Material Disposal Area (MDA) G and the Zone 4 expansion area. To date, disposal operations have been confined to MDA G and are scheduled to continue in that region until MDA G undergoes final closure at the end of 2013. Given its impending closure, efforts

  2. Building waste management in Bulgaria: challenges and opportunities

    International Nuclear Information System (INIS)

    Hadjieva-Zaharieva, R.; Dimitrova, E.; Buyle-Bodin, Francois

    2003-01-01

    Building waste recycling as aggregates is a modern approach for preventing environmental pollution through both reducing the stocks of waste and decreasing the use of natural aggregates. The reuse of building waste is a relatively new issue for Bulgaria despite the existing considerable quantity of building waste and the significant changes in the environmental rules applied. The paper discusses generated and potential waste streams in Bulgaria in the context of the social and economic restructuring and recent urban development undergone by the country. The main preliminary conditions for developing the recycling activity such as: streams of building waste, experience in recycling, technical and environmental standardization, appropriate technologies, etc. are examined. The authors analyze current practice and research activities with regard to the implementation of advanced EU building-waste recycling methods. Conclusions are drawn about existing opportunities and the priorities of the needed building waste management strategy in the country

  3. Interim Control Strategy for the Test Area North/Technical Support Facility Sewage Treatment Facility Disposal Pond - Two-year Update

    International Nuclear Information System (INIS)

    L. V. Street

    2007-01-01

    The Idaho Cleanup Project has prepared this interim control strategy for the U.S. Department of Energy Idaho Operations Office pursuant to DOE Order 5400.5, Chapter 11.3e (1) to support continued discharges to the Test Area North/Technical Support Facility Sewage Treatment Facility Disposal Pond. In compliance with DOE Order 5400.5, a 2-year review of the Interim Control Strategy document has been completed. This submittal documents the required review of the April 2005 Interim Control Strategy. The Idaho Cleanup Project's recommendation is unchanged from the original recommendation. The Interim Control Strategy evaluates three alternatives: (1) re-route the discharge outlet to an uncontaminated area of the TSF-07; (2) construct a new discharge pond; or (3) no action based on justification for continued use. Evaluation of Alternatives 1 and 2 are based on the estimated cost and implementation timeframe weighed against either alternative's minimal increase in protection of workers, the public, and the environment. Evaluation of Alternative 3, continued use of the TSF-07 Disposal Pond under current effluent controls, is based on an analysis of four points: - Record of Decision controls will protect workers and the public - Risk of increased contamination is low - Discharge water will be eliminated in the foreseeable future - Risk of contamination spread is acceptable. The Idaho Cleanup Project recommends Alternative 3, no action other than continued implementation of existing controls and continued deactivation, decontamination, and dismantlement efforts at the Test Area North/Technical Support Facility

  4. SEISMIC EVALUATION OF EXISTING MID-RISE REINFORCED CONCRETE BUILDINGS ACCORDING TO SPECIFICATION FOR BUILDING STRUCTURES TO BE BUILT IN DISASTER AREAS

    Directory of Open Access Journals (Sweden)

    Mehmet İNEL

    2007-01-01

    Full Text Available Over the past several decades, Turkey has been hit by devastating earthquakes and remarkable number of reinforced concrete buildings has been damaged in the high seismicity regions of our country. The aim of this study is to evaluate the seismic performance of the mid-rise reinforced concrete buildings that are major part of building stock of our earthquake-prone country, according to recent Turkish Earthquake Code. 4- and 7-story buildings were selected to represent mid-rise building stock. After determining the structural parameters, each building was subjected to pushover analysis and the capacity curves were obtained. Earthquake performance of each building was determined in the light of their capacity curves according to the recent Turkish Earthquake Code.

  5. Technical program plan for the transitioning, decommissioning, and final disposition focus area

    International Nuclear Information System (INIS)

    1994-01-01

    The end of the Cold War and the decision to reduce the size of the nuclear weapons production complex have created a need for DOE to deactivate, decontaminate, and decommission (D ampersand D) a large number of aging, surplus facilities. The nature and magnitude of the facility D ampersand D problems require EM to facilitate the development and application of technologies that will address these problems quickly and cost-effectively. The needed technologies can best be provided by integrating the strengths of DOE's national laboratories with those of industry, universities, and other government agencies. To help focus and direct these activities toward achieving DOE's goals, the EM Office of Technology Development (OTD) devised the strategic concept of an Integrated Demonstration (ID), which involves selecting, demonstrating, testing, and evaluating an integrated set of technologies tailored to provide a complete solution to specific EM problems, such as those posed by D ampersand D. The ID approach allows optimal use of DOE's resources by avoiding duplication of effort and ensuring rapid demonstration of applicable technologies. Many technologies, including both the commercially mature and the innovative, are combined and evaluated for a cradle-to-grave solution to specific EM problems in areas such as D ampersand D. The process will involve transforming an existing problem condition to a desired end state, recycling waste materials generated, wherever feasible, and minimizing requirements for waste disposal. The D ampersand D ID Strategic Plan has been prepared by a Technical Support Group (TSG) assembled from various sites within the DOE Complex and intended to identify cross-cutting problem areas amenable to applications of the D ampersand D ID concept and to develop specific ID proposals for these problem areas

  6. Corrective Action Decision Document, Area 15 Environmental Protection Agency Farm Laboratory Building, Corrective Action Unit No. 95, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-08-18

    This report is the Corrective Action Decision Document (CADD) for the Nevada Test Site (NTS) Area 15 U.S. Environmental Protection Agency (EPA) Farm, Laboratory Building (Corrective Action Unit [CAU] No. 95), at the Nevada Test Site, Nye County, Nevada. The scope of this CADD is to identify and evaluate potential corrective action alternatives for the decommissioning and decontamination (D and D) of the Laboratory Building, which were selected based on the results of investigative activities. Based on this evaluation, a preferred corrective action alternative is recommended. Studies were conducted at the EPA Farm from 1963 to 1981 to determine the animal intake and retention of radionuclides. The main building, the Laboratory Building, has approximately 370 square meters (4,000 square feet) of operational space. Other CAUS at the EPA Farm facility that will be investigated and/or remediated through other environmental restoration subprojects are not included in this CADD, with the exception of housekeeping sites. Associated structures that do not require classification as CAUS are considered in the evaluation of corrective action alternatives for CAU 95.

  7. Corrective Action Decision Document, Area 15 Environmental Protection Agency Farm Laboratory Building, Corrective Action Unit No. 95, Revision 0

    International Nuclear Information System (INIS)

    1997-01-01

    This report is the Corrective Action Decision Document (CADD) for the Nevada Test Site (NTS) Area 15 U.S. Environmental Protection Agency (EPA) Farm, Laboratory Building (Corrective Action Unit [CAU] No. 95), at the Nevada Test Site, Nye County, Nevada. The scope of this CADD is to identify and evaluate potential corrective action alternatives for the decommissioning and decontamination (D and D) of the Laboratory Building, which were selected based on the results of investigative activities. Based on this evaluation, a preferred corrective action alternative is recommended. Studies were conducted at the EPA Farm from 1963 to 1981 to determine the animal intake and retention of radionuclides. The main building, the Laboratory Building, has approximately 370 square meters (4,000 square feet) of operational space. Other CAUS at the EPA Farm facility that will be investigated and/or remediated through other environmental restoration subprojects are not included in this CADD, with the exception of housekeeping sites. Associated structures that do not require classification as CAUS are considered in the evaluation of corrective action alternatives for CAU 95

  8. Building Software, Building Community: Lessons from the Ropensci Project

    Science.gov (United States)

    Boettiger, C.

    2014-12-01

    rOpenSci is a developer collective originally formed in 2011 by graduate students and post-docs from ecology and evolutionary biology to collaborate on building software tools to facilitate a more open and synthetic approach in the face of transformative rise of large and heterogeneous data. Born on the internet (the collective only began through chance discussions over social media), we have grown into a widely recognized effort that supports an ecosystem of some 45software packages, engages scores of collaborators, has taught dozens of workshops around the world, and has secured over $480,000 in grant support. As young scientists working in an academic context largely without direct support for our efforts, we have first hand experience with most of the the technical and social challenges in developing sustainable scientific software. I will summarize our experiences, the challenges we have faced, and describe our approach and success in building an effective and diverse community around the rOpenSci project.

  9. Check and evaluation system on heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of china based on multi-index comprehensive evaluation method

    International Nuclear Information System (INIS)

    Zhao Jing; Wu Yong; Zhu Neng

    2009-01-01

    Heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China is organized and implemented in a large scale by local government in 15 provinces of North China with the unified guidance and control of central government. Firstly, this paper introduced the target of energy-saving reformation of existing residential buildings in North China and the importance of check and evaluation on this target, then pointed out the necessity of building up an evaluation system for energy-saving retrofit. According to the analytical hierarchy process (AHP), three-grade evaluation system was built up for heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China. Also, based on multi-index comprehensive evaluation method combined with life cycle assessment (LCA) theory, post-evaluation thought and successful degree evaluation method, a mathematical model was established. Finally, a set of scientific method for evaluating heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China systematically, scientifically, comprehensively and objectively was created.

  10. IMCOM LonWorks (registered trademark) Building Automation Systems Implementation Strategy

    National Research Council Canada - National Science Library

    Schwenk, David M; Bush, Joseph; Hughes, Lucie M; Briggs, Stephen; White, Will

    2008-01-01

    ...; however BASs can present their own technical and administrative (including contractual) challenges. This report defines a methodology for the development and execution of a basewide Open Building Automation System...

  11. Learning from tradition. Construction techniques and repair of historical buildings in the area of Brescia: some examples

    Directory of Open Access Journals (Sweden)

    Barbara Scala

    2016-06-01

    The essay focuses on the area of Brescia where, in spite of significant transformations over time of buildings and territory, many examples of traditional architecture still exist. The aim of the paper is also to suggest, by presenting some case studies, a strategy for conservation which proposes a dialogue between traditional methods, technological innovations and economic sustainability of interventions. Keywords: Traditional architecture, Brescia, Sustainability, Construction techniques, Protection

  12. Building Capacity for Evidence-Based Public Health: Reconciling the Pulls of Practice and the Push of Research.

    Science.gov (United States)

    Brownson, Ross C; Fielding, Jonathan E; Green, Lawrence W

    2018-04-01

    Timely implementation of principles of evidence-based public health (EBPH) is critical for bridging the gap between discovery of new knowledge and its application. Public health organizations need sufficient capacity (the availability of resources, structures, and workforce to plan, deliver, and evaluate the preventive dose of an evidence-based intervention) to move science to practice. We review principles of EBPH, the importance of capacity building to advance evidence-based approaches, promising approaches for capacity building, and future areas for research and practice. Although there is general agreement among practitioners and scientists on the importance of EBPH, there is less clarity on the definition of evidence, how to find it, and how, when, and where to use it. Capacity for EBPH is needed among both individuals and organizations. Capacity can be strengthened via training, use of tools, technical assistance, assessment and feedback, peer networking, and incentives. Modest investments in EBPH capacity building will foster more effective public health practice.

  13. Energy efficiency in the Hellenic building sector: An assessment of the restrictions and perspectives of the market

    International Nuclear Information System (INIS)

    Karkanias, C.; Boemi, S.N.; Papadopoulos, A.M.; Tsoutsos, T.D.; Karagiannidis, A.

    2010-01-01

    The significance of bioclimatic architecture has become widely accepted since the 1970s and the implementation of its principles in practice is a key factor in order to achieve energy efficiency in the building sector. The way, however, from scientific acceptance to commercial utilization is not a straightforward one. This paper deals with the notion of bioclimatic architecture in buildings and investigates the aspects of this concept in Hellas. A sample of university researchers, building contractors and members of public organisations was interviewed using a standardised set of guidelines. The barriers to promoting bioclimatic design, role of the local government in the adoption process, level of environmental culture as well as perspectives of this concept in Hellas were the key areas of discussion in each of the interviews. The results from the data analysis reveal insufficient economic incentives, a lack in technical information as well as a lack in specific environmental policies that would foster the propagation of bioclimatic architecture.

  14. Memos with Personality: A Model from British Technical Colleges.

    Science.gov (United States)

    Yee, Carole

    1986-01-01

    Notes that while American technical writing texts stress brevity and directness as important characteristics of business correspondence, British texts stress qualities of personality and courtesy, especially in the memo. Shows how to incorporate personality into correspondence, thereby building cooperation among colleagues. (FL)

  15. Strategies for enhancing the teaching and learning of technical ...

    African Journals Online (AJOL)

    The study evaluated strategies for enhancing the teaching and learning of technical drawing in technical colleges in ebonyi state, Nigeria. Data were collected with the aid of structured interview from twenty technical drawing teachers and 120 technical drawing students in the study area. Data were analysed using mean ...

  16. Technical Cooperation Report for 2014. Report by the Director General [Spanish Version

    International Nuclear Information System (INIS)

    2015-06-01

    The Technical Cooperation Report for 2014 is set out in three parts: A — Strengthening the Agency’s Technical Cooperation Activities; B — TC Programme Resources and Delivery; and C — Programme Activities and Achievements in 2014: Regional Overview. Annex 1 describes examples of project activities and achievements in specific thematic areas, and Annex 2 describes the activities of the Programme of Action for Cancer Therapy. Annex 3 presents the TC programme Fields of Activity, grouped for reporting purposes. Part A is composed of two sections. Part A.1 provides an overview of the Agency’s technical cooperation (TC) activities in 2014. The first section is devoted to the global development context, and highlights the importance of the post-2015 development agenda, and the value of the Sustainable Development Goals’ programmatic framework for the Agency’s technical cooperation activities. The section then describes how the programme is tailored to respond to the specific needs and priorities of each region, focusing on efforts to develop human resources and build capacities in the peaceful application of nuclear science and technology, including through postgraduate training courses, assistance in drafting legislation, distance learning initiatives and technical cooperation among developing countries. The section also presents a snapshot of TC projects that address radioactive waste management, reflecting the topic of the 2014 Scientific Forum. Part A.2 focuses on efforts to build a more efficient and effective TC programme, in particular on efforts to strengthen the Country Programme Framework template. The section reviews progress made in 2014 in establishing and operationalizing partnerships with the United Nations and other relevant international and regional organizations. This section closes with an overview of actions undertaken in 2014 to continually improve the TC programme, notably through training in the Logical Framework Approach, and

  17. The USEPA environmental response team TAGA at work at the Hart building fumigation

    Energy Technology Data Exchange (ETDEWEB)

    Mickunas, D.B.; Turpin, R. [United States Environmental Protection Agency, Edison, NJ (United States). Environmental Response Team; Blaze, S.; Wood, J. [Lockheed Martin Inc., Edison, NJ (United States). Response Engineering and Analytical Contract

    2004-07-01

    This paper describes the fumigation activities conducted at the Hart Senate Office building in Washington, DC in October 2001 following the delivery of a letter containing anthrax. Anthrax spores were dispersed in areas within the office. The United States States Environmental Protection Agency Environmental Response Team (USEPA/ERT) was responsible for the decontamination activities. Chlorine dioxide was chosen as the anthrax sporicide after a detailed technical review and consultation with scientific experts. ERT provided continuous, near real-time ambient air monitoring during the fumigation process. The monitoring was conducted to ensure that the nearby residences were not impacted by the chlorine dioxide fumigant. The monitoring plan required the use of a Trace Atmospheric Gas Analyzer (TAGA), a triple quadrupole mass spectrometer mounted in a mobile laboratory. The monitoring activities of ERT's mobile laboratory were outlined in this paper along with the logistical and technical aspects of the air monitoring. More than 130 hours of TAGA monitoring was performed and 2.3 million data points were collected. No chlorine or chlorine dioxide concentrations were observed above the action limits during any fumigation event. The building was cleared by the health and regulatory agencies and re-opened in January 2002. It was concluded that TAGA is an excellent technology to monitor these compounds because is is extremely sensitive and selective. 2 tabs., 5 figs.

  18. Annual Report for Los Alamos National Laboratory Technical Area 54, Area G Disposal Facility - Fiscal Year 2011

    Energy Technology Data Exchange (ETDEWEB)

    French, Sean B. [Los Alamos National Laboratory; Shuman, Rob [WPS: WASTE PROJECTS AND SERVICES

    2012-05-22

    As a condition to the Disposal Authorization Statement issued to Los Alamos National Laboratory (LANL or the Laboratory) on March 17, 2010, a comprehensive performance assessment and composite analysis maintenance program must be implemented for the Technical Area 54, Area G disposal facility. Annual determinations of the adequacy of the performance assessment and composite analysis are to be conducted under the maintenance program to ensure that the conclusions reached by those analyses continue to be valid. This report summarizes the results of the fiscal year 2011 annual review for Area G. Revision 4 of the Area G performance assessment and composite analysis was issued in 2008 and formally approved in 2009. These analyses are expected to provide reasonable estimates of the long-term performance of Area G and, hence, the disposal facility's ability to comply with Department of Energy (DOE) performance objectives. Annual disposal receipt reviews indicate that smaller volumes of waste will require disposal in the pits and shafts at Area G relative to what was projected for the performance assessment and composite analysis. The future inventories are projected to decrease modestly for the pits but increase substantially for the shafts due to an increase in the amount of tritium that is projected to require disposal. Overall, however, changes in the projected future inventories of waste are not expected to compromise the ability of Area G to satisfy DOE performance objectives. The Area G composite analysis addresses potential impacts from all waste disposed of at the facility, as well as other sources of radioactive material that may interact with releases from Area G. The level of knowledge about the other sources included in the composite analysis has not changed sufficiently to call into question the validity of that analysis. Ongoing environmental surveillance activities are conducted at, and in the vicinity of, Area G. However, the information generated by

  19. Building founding method

    International Nuclear Information System (INIS)

    Tateno, Seiya; Hirako, Shizuka.

    1996-01-01

    The lower portion of a reactor building is buried at a level of a base rock. In the step of building construction, the base rock around the building is dug of keeping a construction space. The base rock present between the digging line and the building is replaced with an artificial base rock comprising aggregates and cement having a building constraining force substantially equal with that of the lower supporting base rock to obtain constraining force for the side portion of the building. The building itself is made of concrete steels. As the material for replacing the base rock between the digging line and the building, non-reinforced concrete having no steels may provide sufficient function. The burying depth is determined so as to align the surface of the base rock with the level of the base floor of the building. With such procedures, since it is not necessary to increase the area of the lower portion of the building, the amount of the materials for the building can be reduced. In addition, the earthquakes stability can be ensured without changing the shape of the building. (I.N.)

  20. Lessons learned from the 2016 Kumamoto earthquake: Building damages and behavior of seismically isolated buildings

    Science.gov (United States)

    Morita, Keiko; Takayama, Mineo

    2017-10-01

    Powerful earthquakes stuck Kumamoto and Oita Prefectures in Kyushu, Japan. It began with the Magnitude 6.5 foreshock at 21:26 JST 14 April, followed by the Magnitude 7.3 mainshock at 1:25 JST 16 April, 2016. The sequence earthquakes also involved more than 1700 perceptible earthquakes as of 13 June. The entire sequence was named the 2016 Kumamoto earthquake by the Japan Meteorological Agency. Thousands of buildings and many roads were damaged, and landslides occurred. The Japanese building standard law is revised in 1981. Structural damages were concentrated on buildings constructed prior to 1981. The area of Mashiki and Southern Aso were most badly affected, especially wooden houses extremely damaged. In Japan, Prof. Hideyuki Tada (title at the time) undertook research on laminated rubber bearings in 1978, and put it into practical use in 1981. The single family house at Yachiyodai, Chiba Prefecture is completed in 1983, it's the first seismically isolated building which is installed laminated rubber bearings in Japan. Afterward, this system is gradually adopted to mainly office buildings, like a research laboratory, a hospital, a computer center and other offices. In the 1994 Northridge earthquake, the 1995 Kobe earthquake and 2011 Tohoku earthquake, seismically isolated buildings improve these good performances, and recently number of the buildings have increased, mainly high risk area of earthquakes. Many people believed that Kumamoto was a low risk area. But there were 24 seismically isolated buildings in Kumamoto Prefecture at the time. The seismically isolated buildings indicated excellent performances during the earthquakes. They protected people, buildings and other important facilities from damages caused by the earthquake. The purpose of this paper is to discuss lessons learned from the 2016 Kumamoto earthquake and behavior of seismically isolated buildings in the earthquake.

  1. Potential and barrier study. Energy efficiency in Norwegian vocational buildings; Potensial- og barrierestudie. Energieffektivisering i norske yrkesbygg

    Energy Technology Data Exchange (ETDEWEB)

    Boehn, Trond Ivar; Palm, Linn Therese; Bakken, Line; Nossum, Aase; Jordell, Hanne

    2012-07-01

    On behalf of Enova SF, Multiconsult AS and Analyse og Strategi AS conducted an analysis to identify potential and barriers related to commercial buildings energy performance. The aim of this study was to determine what is the potential for energy efficiency for Norwegian vocational buildings that distinguishes between theoretical, technical, financial and real potential. Technical potential is the percentage of the theoretical potential that is technically feasible. Economic potential is the proportion of technical potential that is economically profitable to implement. Economic potential varies with the energy price. Build a small part of the total potential in 2020. In the calculation of the real potential is taken into account induced potential in terms of that, each year, a percentage actually implementing energy conservation measures (energy efficiency ratio 2%), a percentage rehabilitating / upgrading existing buildings (rehab rate 1.5%), and that a proportion of new buildings built better than regulatory requirements (rate 10%). In real potential for energy efficiency is the proportion of the economic potential that is not natural triggered but which is limited by various barriers. In real potential also varies with energy price. Respondents in our study is particularly concerned with the economic barriers, and least concerned the technical barriers. Attitudes and knowledge barriers are also very important. Lack of knowledge the effects and benefits of energy efficiency means that negative attitudes persist and that myths about the lack of profitability continues to exist. Many believe this is due to lack the knowledge and can be the cause of other types of barriers such as economic barriers. It has been analyzed which part of the real potential bounded by the barriers, and which type of institutions in society that can reduce these barriers with various categories of instrument. Main barriers for existing buildings practical barriers, economic barriers and

  2. Conserving energy in new buildings: analysis of nonregulatory policies

    Energy Technology Data Exchange (ETDEWEB)

    Scheer, R.M.; Nieves, L.A.; Mazzucchi, R.P.

    1981-05-01

    The costs and effectiveness of non-regulatory options relative to those of a regulatory approach are analyzed. Nonregulatory program alternatives identified are: information and education programs, tax incentives and disincentives, and mortage and finance programs. Chapter 2 briefly reviews survey data to assess present public awareness of energy issues and energy-efficient building design. Homebuyer and homebuilder surveys are reviewed and conservation motivations are discussed. Chapter 3 examines the provision of technical and economic information to various factors affecting building design decisions. This approach assumes that the economic incentives and technical means to achieve energy conservation goals already exist but that critical information is lacking. Chapter 4 examines how adjustments to the tax structure could enhance economic incentives and counter economic disincentives for energy conservation. Qualifying buildings for tax benefits would almost certainly require certification of design energy consumption. The effectiveness of tax incentives would depend in part on dissemination of public information regarding the incentives. Chapter 5 examines subsidies, such as subsidized mortgages and loan guarantees, which lower the cost of money or other costs but do not change the market structure facing the consumer. Certification that buildings qualify for such treatment would probably be required. Chapter 6 presents recommendations based on the study's findings. (MCW)

  3. A review of interdependence of sustainable building

    International Nuclear Information System (INIS)

    Ju, Chuanjing; Ning, Yan; Pan, Wei

    2016-01-01

    ABSTRACT: Despite the worldwide promotion of the sustainable building (SB) approach, its associated interdependence has seldom been explored. This knowledge gap is significant given the paradigm shift of regarding SBs as complex socio-technical systems embedded with multifaceted interdependence. The aim of this paper is to examine the interdependence of SB through a literature review. The literature review was guided by a framework comprising three dimensions of SB systems, i.e., building performance, methodology and stakeholders, on their theoretical grounds ranged from reductionism to holism. In order to articulate the integration of the three dimensions, this paper examined zero carbon building as a specific case of SB. The findings contribute an innovative approach to examining the interdependence of SB, and should guide the development of strategies for managing the trade-offs in delivering SBs. - Highlights: • Performance scope of sustainable building triggers interdependence. • Material flow from cradle to cradle causes interdependence. • Interdependence occurs between the building and their context. • Interdependence exists in stakeholders' participation.

  4. Sault Tribe Building Efficiency Energy Audits

    Energy Technology Data Exchange (ETDEWEB)

    Holt, Jeffrey W.

    2013-09-26

    The Sault Ste. Marie Tribe of Chippewa Indians is working to reduce energy consumption and expense in Tribally-owned governmental buildings. The Sault Ste. Marie Tribe of Chippewa Indians will conduct energy audits of nine Tribally-owned governmental buildings in three counties in the Upper Peninsula of Michigan to provide a basis for evaluating and selecting the technical and economic viability of energy efficiency improvement options. The Sault Ste. Marie Tribe of Chippewa Indians will follow established Tribal procurement policies and procedures to secure the services of a qualified provider to conduct energy audits of nine designated buildings. The contracted provider will be required to provide a progress schedule to the Tribe prior to commencing the project and submit an updated schedule with their monthly billings. Findings and analysis reports will be required for buildings as completed, and a complete Energy Audit Summary Report will be required to be submitted with the provider?s final billing. Conducting energy audits of the nine governmental buildings will disclose building inefficiencies to prioritize and address, resulting in reduced energy consumption and expense. These savings will allow Tribal resources to be reallocated to direct services, which will benefit Tribal members and families.

  5. Technical presentation

    CERN Document Server

    FP Department

    2009-01-01

    07 April 2009 Technical presentation by Leuze Electronics: 14.00 – 15.00, Main Building, Room 61-1-017 (Room A) Photoelectric sensors, data identification and transmission systems, image processing systems. We at Leuze Electronics are "the sensor people": we have been specialising in optoelectronic sensors and safety technology for accident prevention for over 40 years. Our dedicated staff are all highly customer oriented. Customers of Leuze Electronics can always rely on one thing – on us! •\tFounded in 1963 •\t740 employees •\t115 MEUR turnover •\t20 subsidiaries •\t3 production facilities in southern Germany Product groups: •\tPhotoelectric sensors •\tIdentification and measurements •\tSafety devices

  6. FUNCTIONS OF THE IMAGE IN SHAPING THE TECHNICAL THINKING OF STUDENTS

    Directory of Open Access Journals (Sweden)

    Mariusz Śniadkowski

    2014-11-01

    Full Text Available The world of technology can be a tool to support development processes, primarily cognitive, emotional and motivational. Adoption issues shaping the image function in the technical thinking of students is justified in many ways: a – impact on the development of human image; b – multidimensional image and diversity of its media resources; c – the influence of the image on shaping the attitudes and behaviors of education; d – state of research on the evolution of technical thinking of youth. Development of the technical thinking is one of the objectives in the process of technical education. A picture taking part in it by building concepts and technical imagination fulfilling a significant role in the illustration and understanding of issues and technical products and the specific technical action. Technical education requires from teachers to enter a wide range of activities in the teaching process in the direction of the effective application and the use of image in the development of technical thinking and imagination of students. Pictures have a prominent role here.

  7. On the Matter of NPP New Builds

    International Nuclear Information System (INIS)

    Stosic, Z. V.

    2010-01-01

    In the past decades the nuclear option has developed to become a measure to secure the energy supply not only of the established nuclear nations, but also of newly embarking or smaller countries without significant nuclear experience. In these small countries cooperation may work cross-border between countries or cross-corporate between manufacturers and/or utilities. Since the time span between decision-making for building, the licensing procedure, the detailed planning, the construction phase and commissioning can amount to 10-15 (and even more) years, this leads to the public discussions and urgent requirements of having to incorporate the constant experience gained on all technical, administrative (regulatory and authorities) and political (governmental) levels. This has to be taken into account for the safety-related boundary conditions in the frame of a new build project. Often neglected is the fact that this also applies to the choice of the guidelines to put into effect, to an efficient and competent authority and utility body and the integration of adequate technical specialists. Utilities face different requirements depending on whether they are situated in the country of responsible nuclear power plant utilities' headquarters or whether they are merely co-owners of a foreign plant. All these matters profit from resorting to the knowledge pool from operational experiences and experiences gained in new build projects. Regarding a new build project the milestones in the development of a national nuclear power infrastructure as well as involvement of the main local (national) organizations and progressive application of the IAEA safety requirements are presented. Workforce planning during construction and operation including educational needs is shown for a single country example. A breakdown of total contract amount and activity itemization is given. Aspects of a new build project are discussed for two typical examples: (i) New Build Plan - starting with

  8. Solar energy potential of the largest buildings in the United States

    Science.gov (United States)

    Wence, E. R.; Grodsky, S.; Hernandez, R. R.

    2017-12-01

    Sustainable pathways of land use for energy are necessary to mitigate climate change and limit conversion of finite land resources needed for conservation and food production. Large, commercial buildings (LCBs) are increasing in size and number throughout the United States (US) and may serve as suitable recipient environments for photovoltaic (PV) solar energy infrastructure that may support a low carbon, low land footprint energy transition. In this study, we identified, characterized, and evaluated the technical potential of the largest, commercial building rooftops (i.e., exceeding 110,000 m2) and their associated parking lots in the US for PV solar energy systems using Aurora, a cloud-based solar optimization platform. We also performed a case study of building-specific electricity generation: electricity consumption balance. Further, we quantified the environmental co-benefit of land sparing and associated avoided emissions (t-CO2-eq) conferred under the counterfactual scenario that solar development would otherwise proceed as a ground-mounted, utility-scale PV installation of equal nominal capacity. We identified and mapped 37 LCBs (by rooftop area) across 18 states in the US, spanning from as far north as the state of Minnesota to as far south as Florida. Rooftop footprints range from 427,297 to 113,689 m2 and have a cumulative surface area of 99.8 million ft2. We characterize the LCBs as either: distribution/warehouse, factory, shopping center, or administrative office/facility. Three of the 37 LCBs currently support rooftop PV and the numbers of associated, detached buildings number up to 38. This study elucidates the extent to which LCBs and their respective parking lots can serve as suitable sites for PV solar energy generation. Lastly, this study demonstrates research-based applications of the Aurora energy modeling platform and informs decision-making focused on redirecting energy development towards human-modified landscapes to prioritize land use for

  9. TECHNICAL COORDINATION

    CERN Multimedia

    A. Ball

    Overview From a technical perspective, CMS has been in “beam operation” state since 6th November. The detector is fully closed with all components operational and the magnetic field is normally at the nominal 3.8T. The UXC cavern is normally closed with the radiation veto set. Access to UXC is now only possible during downtimes of LHC. Such accesses must be carefully planned, documented and carried out in agreement with CMS Technical Coordination, Experimental Area Management, LHC programme coordination and the CCC. Material flow in and out of UXC is now strictly controlled. Access to USC remains possible at any time, although, for safety reasons, it is necessary to register with the shift crew in the control room before going down.It is obligatory for all material leaving UXC to pass through the underground buffer zone for RP scanning, database entry and appropriate labeling for traceability. Technical coordination (notably Stephane Bally and Christoph Schaefer), the shift crew and run ...

  10. Reliability and service life of wood structures and buildings

    Directory of Open Access Journals (Sweden)

    Zdeňka Havířová

    2005-01-01

    Full Text Available Service life of constructions and buildings of wood is dependent on temperature and moisture conditions in layers of the building cladding where the wood framework is built in. Temperature/moisture conditions or the corresponding equilibrium moisture content (EMC of the construction show considerable effects on the functional reliability of the whole building from the viewpoint of mechanical resistance and stability (ER1, energy savings and thermal protection (ER6 and hygiene, health and environment protection (ER3. To ensure the reliability of constructions and buildings for the period of their supposed service life a more profound analysis of constructions is necessary from the aspect of a global thermal/technical evaluation.

  11. Radiological consequences of radioactive substances in building materials

    International Nuclear Information System (INIS)

    Tschurlovits, M.

    1982-01-01

    A review of radiological consequences of radioactive substances in building materials is given. Where the other contributing papers are dealing with technical problems and measuring techniques, this paper is going beyond the term dose and is considering the risk by radioactive substances in building materials in relation to conventional risks. The present state of international standards is also discussed. If a limit of 1 mSv is adopted, it is shown that this limit is just met at present conditions. (Author) [de

  12. The research on regional conservation planning of urban historical and cultural areas based on GIS

    Science.gov (United States)

    Li, Shangli; Xu, Jian; Li, Qian

    2017-06-01

    With the rapid economic development and the growth of population happening in the urban historical and cultural areas, heritage and historical buildings along with their natural and artificial surrounding environments are suffering constructive destruction. Due to the lack of precise partition of protection region and construction control region in the local cultural relics protection law, traditional regional conservation planning cannot engaged with the urban controllability detailed planning very well. According to the several protection regulations about heritage and historical buildings from latest laws, we choose Baxian Temple area to study on the improvments of traditional regional conservation planning. The technical methods of this study mainly rely on GIS, which can complete the fundamental work of each stage. With the analytic hierarchy process(AHP), the comprehensive architectural value assessments can be calculated according to the investigation results. Based on the calculation results and visual corridor analysis, the precise range of protection region and construction control region can be decided and the specific protection measures can be formulated.

  13. Turning Technologies into Businesses- The Challenge for the Technical Entrepreneur

    Science.gov (United States)

    Glass, Alexander

    2000-03-01

    Over the past twenty-five years, new businesses based on innovative technology have been the driving force for the US economy. Due to the abundance of early-stage capital, each year, thousands of scientists and engineers receive support to start new, technology-based businesses. However, the transition from technologist to entrepreneur is often difficult. It requires a shift in emphasis from a technology focus to a market focus. We shall discuss the challenges facing the technical entrepreneur in launching a new enterprise, and a variety of resources that are available to help the entrepreneur succeed. Many technologists fall victim to the myth that if you ``build a better mousetrap, the world will beat a path to your door." To be sure, it is important to base your business on sound technology that offers a clear advantage over current practice, and, if possible, to secure title to the technology, either by obtaining patent protection, or securing an exclusive license. Once that is done, however, the principal concern of the fledgling enterprise is building a business and obtaining the financial resources to enable it to grow. The entrepreneur must develop a clear and compelling business model, that can be communicated to a non-technical investor in a few minutes. This requires a mode of thinking and expression quite different from that commonly used in engineering or scientific discussions. Fortunately, abundant resources are available to help the technologist become a successful entrepreneur. We shall discuss the kinds of assistance that are generally available through local and national programs, and give specific examples based on the activities of the Bay Area Regional Technology Alliance in northern California.

  14. Developing and Validating the Socio-Technical Model in Ontology Engineering

    Science.gov (United States)

    Silalahi, Mesnan; Indra Sensuse, Dana; Giri Sucahyo, Yudho; Fadhilah Akmaliah, Izzah; Rahayu, Puji; Cahyaningsih, Elin

    2018-03-01

    This paper describes results from an attempt to develop a model in ontology engineering methodology and a way to validate the model. The approach to methodology in ontology engineering is from the point view of socio-technical system theory. Qualitative research synthesis is used to build the model using meta-ethnography. In order to ensure the objectivity of the measurement, inter-rater reliability method was applied using a multi-rater Fleiss Kappa. The results show the accordance of the research output with the diamond model in the socio-technical system theory by evidence of the interdependency of the four socio-technical variables namely people, technology, structure and task.

  15. Technical Note: Application of Decision Theory Based Criteria for ...

    African Journals Online (AJOL)

    Technical Note: Application of Decision Theory Based Criteria for Structural Appraisal of a Building during Construction. ... Nigerian Journal of Technology ... reliability of concrete in a structure during construction, a case study of laboratory block for College of Continuing Education, University of Port Harcourt, Rivers State.

  16. Radon classification of building ground

    International Nuclear Information System (INIS)

    Slunga, E.

    1988-01-01

    The Laboratories of Building Technology and Soil Mechanics and Foundation Engineering at the Helsinki University of Technology in cooperation with The Ministry of the Environment have proposed a radon classification for building ground. The proposed classification is based on the radon concentration in soil pores and on the permeability of the foundation soil. The classification includes four radon classes: negligible, normal, high and very high. Depending on the radon class the radon-technical solution for structures is chosen. It is proposed that the classification be done in general terms in connection with the site investigations for the planning of land use and in more detail in connection with the site investigations for an individual house. (author)

  17. Fiber optic sensor based on Mach-Zehnder interferometer for securing entrance areas of buildings

    Science.gov (United States)

    Nedoma, Jan; Fajkus, Marcel; Martinek, Radek; Mec, Pavel; Novak, Martin; Bednarek, Lukas; Vasinek, Vladimir

    2017-10-01

    Authors of this article focused on the utilization of fiber optic sensors based on interferometric measurements for securing entrance areas of buildings such as windows and doors. We described the implementation of the fiber-optic interferometer (type Mach-Zehnder) into the window frame or door, sensor sensitivity, analysis of the background noise and methods of signal evaluation. The advantage of presented solution is the use of standard telecommunication fiber standard G.652.D, high sensitivity, immunity of sensor to electromagnetic interference (EMI) and passivity of the sensor regarding power supply. Authors implemented the Graphical User Interface (GUI) which offers the possibility of remote monitoring presented sensing solution.

  18. Photovoltaics in buildings. Final report; Photovoltaik in Gebaeuden. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Erge, T.; Hullmann, H.; Kaiser, R.; Kovach-Hebling, A.; Laukamp, H.; Reise, C.; Sauer, D.U.; Schmid, J.; Schmidt, H.; Sick, F.

    1996-08-31

    The feasibility in principle of photovoltaic plants integrated in buildings was proved in the 1980`s in the context of several pilot and demonstration projects both in Germany and internationally. However, the realisation and operation of these plants showed the necessity for further research and development work both in the system technique and particularly in the architectural area. The research project `Photovoltaics in buildings` reached the target of establishing a bridge between the technically orientated work of the researchers, developers and manufacturers of photovoltaic components on the one hand, and the architects and town planners on the other hand. (orig./AKF) [Deutsch] Die prinzipielle Machbarkeit gebaeudeintegrierter Photovoltaikanlagen wurde in den 80er Jahren im Rahmen mehrerer Pilot- und Demonstrationsprojekte sowohl in der Bundesrepublik Deutschland als auch international nachgewiesen. Die Realisierung und der Betrieb dieser Anlagen zeigte jedoch die Notwendigkeit weiterer Forschungs- und Entwicklungsarbeiten sowohl im systemtechnischen als insbesondere auch im architektonischen Bereich auf. Mit dem Forschungsprojekt `Photovoltaik in Gebaeuden` wurde das Ziel erreicht, eine Bruecke zu schlagen zwischen den eher technisch orientierten Arbeiten der Forscher, Entwickler und Hersteller von Photovoltaikkomponenten auf der einen Seite und den Architekten und Stadtplanern auf der anderen. (orig./AKF)

  19. Low-level waste drum staging building at Weapons Engineering Tritium Facility, TA-16, Los Alamos National Laboratory, Los Alamos, New Mexico. Environmental Assessment

    International Nuclear Information System (INIS)

    1994-08-01

    The proposed action is to place a 3 meter (m) by 4.5 m (10 ft x 15 ft) prefabricated storage building (transportainer) adjacent to the existing Weapons Engineering Tritium Facility (WETF) at Technical Area (TA-) 16, Los Alamos National Laboratory (LANL), and to use the building as a staging site for sealed 55 galllon drums of noncompactible waste contaminated with low levels of tritium (LLW). Up to eight drums of waste would be accumulated before the waste is moved by LANL Waste Management personnel to the existing on-site LLW disposal area at TA-54. The drum staging building would be placed on a bermed asphalt pad, near other existing accumulation structures for office trash and compactible LLW. The no-action alternative is to continue storing drums of LLW in the WETF laboratories where they occupy valuable work space, hamper movement of personnel and equipment, and require waste management personnel to enter those laboratories in order to remove filled drums. No new waste would be generated by implementing the proposed action; no changes or increases in WETF operations or waste production rate are anticipated as a result of staging drums of LLW outside the main laboratory building. The site for the LLW drum staging building would not impact any sensitive areas. Tritium emissions from the drums of LLW were included within the source term for normal operations at the WETF; the cumulative impacts would not be increased

  20. Whole-Building Design Increases Energy Efficiency in a Mixed-Humid Climate: Ideal Homes, Norman, Oklahoma

    International Nuclear Information System (INIS)

    Poole, L.; Anderson, R.

    2001-01-01

    New houses designed by Ideal Homes, with technical support from the U.S. Department of Energy's Building America Program, save their homeowners money by applying the principles of ''whole-building'' design. The homes are in Norman, Oklahoma