WorldWideScience

Sample records for btu meters

  1. Development of a hydronic Btu meter for multi-family applications. Final report, March 1, 1990-April 30, 1991

    Energy Technology Data Exchange (ETDEWEB)

    Staples, E.J.; Watson, G.W.

    1991-12-01

    The objective of the GRI BTU meter development was to provide a low cost metering system for central hydronic heating and cooling systems which are used to determine individual tenant energy usage. A major goal has been achieved with the development of a low cost BTU meter to monitor energy usage in multi-tenant dwellings with centralized hydronic heating and cooling. The system can provide accurate sub-metering and maintenance-free battery operation for 5 years. The BTU meters are capable of independent operation (requiring periodic reading) or can be interfaced to a computer. The application of BTU meters for heating cost allocation (HCA) in multi-family buildings was studied in order to better understand their use in the more general HCA market. At the present time an ASHRAE committee is formulating HCA system standards. Lacking such standards, it was concluded that beta site testing should not be started until HCA standards are released by the ASHRAE committee on allocation methods. Recommendations are to monitor the ASHRAE committees progress and to encourage standards which will enable gas utilities to more effectively compete for multi-family business and market share.

  2. Technology characterization: high Btu gas transmission

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-04-01

    A technology characterization for high Btu gas transmission was prepared. The scope of work was confined to a literature review. The work was divided into four specific areas as follows: (1) a summary of pertinent information from the environmental report of the Great Lakes Gas Company for a 365-mile high pressure pipeline serving American Natural Gas Company's proposed lignite gasification plant in North Dakota; (2) statistical information concerning the operation of the existing United States natural gas transmission pipeline network; (3) a summary of pertinent information from the environmental impact statement of the United States Department of Interior for the proposed 1,619-mile Northern Border Pipeline from Morgan, Montana to Delmont, Pennsylvania; and (4) a summary of pertinent information from the environmental impact statement of the Federal Power Commission for a proposed El Paso Natural Gas Company 418-mile pipeline within the State of Texas which was to be constructed in response to the displacement of natural gas by Liquefied Natural Gas (LNG) importation on the East Coast.

  3. Low- and medium-Btu coal gasification processes

    Energy Technology Data Exchange (ETDEWEB)

    Baker, N.R.; Blazek, C.F.; Tison, R.R.

    1979-01-01

    Coal gasifiers, for the production of low- and medium-Btu fuel gases, come in a wide variety of designs and capacities. For single gasifier vessels gas energy production rates range from about 1 to 18 billion Btu/day. The key characteristics of gasifiers that would be of importance for their application as an energy source in Integrated Community Energy Systems (ICES) are evaluated here. The types of gasifiers considered here are single- and two-stage, fixed-bed units; fluidized-bed units; and entrained-bed units, as producers of both low-Btu (less than 200 Btu/SCF and medium-Btu (200 to 400 Btu/SCF) gases. The gasifiers are discussed with respect to maximum and minimum capacity, the effect of feed coal parameters, product characteristics, thermal efficiency, environmental effects, operating and maintenance requirements, reliability, and cost. Some of the most recent development work in this area of coal conversion, and use of these gas products also is considered. Except in small plant installations (< 10/sup 9/ Btu/day) the annual operating costs for the various gasifier types are approximately the same. This is somewhat surprising in view of the personnel requirements, efficiencies, utility requirements, heating value of the product gas, and operating characteristics associated with each. Operating costs tend to increase with a power function exponent of 0.92 (i.e., a doubling in plant capacity increases the operating cost by about 1.9).

  4. Performance of low-Btu fuel gas turbine combustors

    Energy Technology Data Exchange (ETDEWEB)

    Bevan, S.; Bowen, J.H.; Feitelberg, A.S.; Hung, S.L.; Lacey, M.A.; Manning, K.S.

    1995-11-01

    This reports on a project to develop low BTU gas fuel nozzle for use in large gas turbine combustors using multiple fuel nozzles. A rich-quench-lean combustor is described here which reduces the amount of NO{sub x} produced by the combustion of the low BTU gas. The combustor incorporates a converging rich stage combustor liner, which separates the rich stage recirculation zones from the quench stage and lean stage air.

  5. In vitro functional characterization of BtuCD-F, the Escherichia coli ABC transporter for vitamin B-12 uptake

    NARCIS (Netherlands)

    Borths, EL; Poolman, B; Hvorup, RN; Locher, KP; Rees, DC; Hvorup, Rikki N.; Locher, Kaspar P.; Rees, Douglas C.

    2005-01-01

    BtuCD is an ATP binding cassette (ABC) transporter that facilitates uptake of vitamin B-12 into the cytoplasm of Escherichia coli. The crystal structures of BtuCD and its cognate periplasmic binding protein BtuF have been recently determined. We have now explored BtuCD-F function in vitro, both in

  6. Repression of btuB gene transcription in Escherichia coli by the GadX protein

    Directory of Open Access Journals (Sweden)

    Hu Wensi S

    2011-02-01

    Full Text Available Abstract Background BtuB (B twelve uptake is an outer membrane protein of Escherichia coli, it serves as a receptor for cobalamines uptake or bactericidal toxin entry. A decrease in the production of the BtuB protein would cause E. coli to become resistant to colicins. The production of BtuB has been shown to be regulated at the post-transcriptional level. The secondary structure switch of 5' untranslated region of butB and the intracellular concentration of adenosylcobalamin (Ado-Cbl would affect the translation efficiency and RNA stability of btuB. The transcriptional regulation of btuB expression is still unclear. Results To determine whether the btuB gene is also transcriptionally controlled by trans-acting factors, a genomic library was screened for clones that enable E. coli to grow in the presence of colicin E7, and a plasmid carrying gadX and gadY genes was isolated. The lacZ reporter gene assay revealed that these two genes decreased the btuB promoter activity by approximately 50%, and the production of the BtuB protein was reduced by approximately 90% in the presence of a plasmid carrying both gadX and gadY genes in E. coli as determined by Western blotting. Results of electrophoretic mobility assay and DNase I footprinting indicated that the GadX protein binds to the 5' untranslated region of the btuB gene. Since gadX and gadY genes are more highly expressed under acidic conditions, the transcriptional level of btuB in cells cultured in pH 7.4 or pH 5.5 medium was examined by quantitative real-time PCR to investigate the effect of GadX. The results showed the transcription of gadX with 1.4-fold increase but the level of btuB was reduced to 57%. Conclusions Through biological and biochemical analysis, we have demonstrated the GadX can directly interact with btuB promoter and affect the expression of btuB. In conclusion, this study provides the first evidence that the expression of btuB gene is transcriptionally repressed by the acid

  7. Recent regulatory experience of low-Btu coal gasification. Volume III. Supporting case studies

    Energy Technology Data Exchange (ETDEWEB)

    Ackerman, E.; Hart, D.; Lethi, M.; Park, W.; Rifkin, S.

    1980-02-01

    The MITRE Corporation conducted a five-month study for the Office of Resource Applications in the Department of Energy on the regulatory requirements of low-Btu coal gasification. During this study, MITRE interviewed representatives of five current low-Btu coal gasification projects and regulatory agencies in five states. From these interviews, MITRE has sought the experience of current low-Btu coal gasification users in order to recommend actions to improve the regulatory process. This report is the third of three volumes. It contains the results of interviews conducted for each of the case studies. Volume 1 of the report contains the analysis of the case studies and recommendations to potential industrial users of low-Btu coal gasification. Volume 2 contains recommendations to regulatory agencies.

  8. Low-Btu coal gasification in the United States: company topical. [Brick producers

    Energy Technology Data Exchange (ETDEWEB)

    Boesch, L.P.; Hylton, B.G.; Bhatt, C.S.

    1983-07-01

    Hazelton and other brick producers have proved the reliability of the commercial size Wellman-Galusha gasifier. For this energy intensive business, gas cost is the major portion of the product cost. Costs required Webster/Hazelton to go back to the old, reliable alternative energy of low Btu gasification when the natural gas supply started to be curtailed and prices escalated. Although anthracite coal prices have skyrocketed from $34/ton (1979) to over $71.50/ton (1981) because of high demand (local as well as export) and rising labor costs, the delivered natural gas cost, which reached $3.90 to 4.20/million Btu in the Hazelton area during 1981, has allowed the producer gas from the gasifier at Webster Brick to remain competitive. The low Btu gas cost (at the escalated coal price) is estimated to be $4/million Btu. In addition to producing gas that is cost competitive with natural gas at the Webster Brick Hazelton plant, Webster has the security of knowing that its gas supply will be constant. Improvements in brick business and projected deregulation of the natural gas price may yield additional, attractive cost benefits to Webster Brick through the use of low Btu gas from these gasifiers. Also, use of hot raw gas (that requires no tar or sulfur removal) keeps the overall process efficiency high. 25 references, 47 figures, 14 tables.

  9. The generation of electricity by gas turbines using the catalytic combustion of low-Btu gases

    DEFF Research Database (Denmark)

    Frederiksen, O.P.; Qvale, Einar Bjørn

    1989-01-01

    Various systems for the generation of electricity by gas turbines using catalytic combustion of low-Btu gases have been investigated. Parametric studies of three configurations that are deemed to be practically feasible have been completed. It is shown that thermodynamic efficiency of these systems...

  10. Low-Btu gasifer emissions toxicology status report, December 1, 1980-May 31, 1981

    Energy Technology Data Exchange (ETDEWEB)

    Benson, J M [ed.

    1982-03-01

    The goal is to assess inhalation hazards to plant workers and the general population that may be associated with low Btu coal gasification. To achieve this goal, it is necessary to characterize the potential toxicants in liquid and solid process and waste streams. To these ends, the experimental low Btu gasifier at the Morgantown Energy Technology Center (METC) has been sampled to determine aerosol components in gaseous process streams and to assess potential toxicants in liquid and solid effluent streams. The most recent sampling efforts were in September 1980 and June 1981. This report concentrates on results obtained from December 1, 1980 to June 1, 1981 and does not include results of the June 1981 sampling trip.

  11. Technical Road Testing of the 18,000 BTU Air Conditioners (Vibration Profile)

    Science.gov (United States)

    1990-06-27

    equimped with a calibrated fifth wheel driven speedanetr. Instrumented testing was crducted on the Mzso area izproved gravel road, Belgian block, two...item, conducting the test, and acquiring and processing all test data. 1.5 SYSTEM DESCRIPTION Two 50/60 Hz, 3-2hase, 208-volt, 18,000 BTU/hr compact...operationally checked periodically and at the conclusion of the road vibration test. A limited amount of data processing was performed at the test

  12. Low/medium-Btu coal-gasification assessment program for specific sites of two New York utilities

    Energy Technology Data Exchange (ETDEWEB)

    1980-12-01

    The scope of this study is to investigate the technical and economic aspects of coal gasification to supply low- or medium-Btu gas to the two power plant boilers selected for study. This includes the following major studies (and others described in the text): investigate coals from different regions of the country, select a coal based on its availability, mode of transportation and delivered cost to each power plant site; investigate the effects of burning low- and medium-Btu gas in the selected power plant boilers based on efficiency, rating and cost of modifications and make recommendations for each; and review the technical feasibility of converting the power plant boilers to coal-derived gas. The following two coal gasification processes have been used as the basis for this Study: the Combustion Engineering coal gasification process produces a low-Btu gas at approximately 100 Btu/scf at near atmospheric pressure; and the Texaco coal gasification process produces a medium-Btu gas at 292 Btu/scf at 800 psig. The engineering design and economics of both plants are described. Both plants meet the federal, state, and local environmental requirements for air quality, wastewater, liquid disposal, and ground level disposal of byproduct solids. All of the synthetic gas alternatives result in bus bar cost savings on a yearly basis within a few years of start-up because the cost of gas is assumed to escalate at a lower rate than that of fuel oil, approximately 4 to 5%.

  13. Design and Performance of a Low Btu Fuel Rich-Quench-Lean Gas Turbine Combustor

    Energy Technology Data Exchange (ETDEWEB)

    Feitelberg, A.S.; Jackson, M.R.; Lacey, M.A.; Manning, K.S.; Ritter, A.M.

    1996-12-31

    General Electric Company is developing gas turbines and a high temperature desulfurization system for use in integrated gasification combined cycle (IGCC) power plants. High temperature desulfurization, or hot gas cleanup (HGCU), offers many advantages over conventional low temperature desulfurization processes, but does not reduce the relatively high concentrations of fuel bound nitrogen (FBN) that are typically found in low Btu fuel. When fuels containing bound nitrogen are burned in conventional gas turbine combustors, a significant portion of the FBN is converted to NO{sub x}. Methods of reducing the NO{sub x} emissions from IGCC power plants equipped with HGCU are needed. Rich-quench-lean (RQL) combustion can decrease the conversion of FBN to NO{sub x} because a large fraction of the FBN is converted into non-reactive N{sub 2} in a fuel rich stage. Additional air, required for complete combustion, is added in a quench stage. A lean stage provides sufficient residence time for complete combustion. Objectives General Electric has developed and tested a rich-quench-lean gas turbine combustor for use with low Btu fuels containing FBN. The objective of this work has been to design an RQL combustor that has a lower conversion of FBN to N{sub x} than a conventional low Btu combustor and is suitable for use in a GE heavy duty gas turbine. Such a combustor must be of appropriate size and scale, configuration (can-annular), and capable of reaching ``F`` class firing conditions (combustor exit temperature = 2550{degrees}F).

  14. Low-btu gas in the US Midcontinent: A challenge for geologists and engineers

    Science.gov (United States)

    Newell, K.D.; Bhattacharya, S.; Sears, M.S.

    2009-01-01

    Several low-btu gas plays can be defined by mapping gas quality by geological horizon in the Midcontinent. Some of the more inviting plays include Permian strata west of the Central Kansas uplift and on the eastern flank of Hugoton field and Mississippi chat and other pays that subcrop beneath (and directly overlie) the basal Pennsylvanian angular unconformity at the southern end of the Central Kansas uplift. Successful development of these plays will require the cooperation of reservoir geologists and process engineers so that the gas can be economically upgraded and sold at a nominal pipeline quality of 950 btu/scf or greater. Nitrogen is the major noncombustible contaminant in these gas fields, and various processes can be utilized to separate it from the hydrocarbon gases. Helium, which is usually found in percentages corresponding to nitrogen, is a possible ancillary sales product in this region. Its separation from the nitrogen, of course, requires additional processing. The engineering solution for low-btu gas depends on the rates, volumes, and chemistry of the gas needing upgrading. Cryogenic methods of nitrogen removal are classically used for larger feed volumes, but smaller feed volumes characteristic of isolated, low-pressure gas fields can now be handled by available small-scale PSA technologies. Operations of these PSA plants are now downscaled for upgrading stripper well gas production. Any nitrogen separation process should be sized, within reason, to match the anticipated flow rate. If the reservoir rock surprises to the upside, the modularity of the upgrading units is critical, for they can be stacked to meet higher volumes. If a reservoir disappoints (and some will), modularity allows the asset to be moved to another site without breaking the bank.

  15. Your Glucose Meter

    Science.gov (United States)

    ... by Audience For Women Women's Health Topics Your Glucose Meter Share Tweet Linkedin Pin it More sharing ... Your Blood Sugar and Caring for Your Meter Glucose meters test and record how much sugar (called ...

  16. Evaluation of the Battelle Agglomerating Ash Burner High Btu Coal Gasification Process

    Energy Technology Data Exchange (ETDEWEB)

    Malow, M.; West, A.S.

    1978-06-01

    The economics of the Battelle Agglomerating Ash Burner Process for the production of high Btu gas (SNG) from coal has been evaluated. A conceptual process design including process flowsheets, heat and material balances and equipment specifications has been prepared. Capital costs, operating costs and gas costs have been developed using the CFBraun ''Gas Cost Guidelines''. The estimated capital and gas costs for the Battelle process have been compared to the alternative high Btu processes described in CFBraun's ''Factored Estimates for Western Coal Commercial Concepts'' and were found to be economically unattractive. Some of the reasons for the higher capital cost and gas costs for the Battelle process are: Low Gasifier and Combustor Operating Pressure, Low Methane Make and Concentration in the Gasifier Effluent, Large Volume of Combustion Gases Produced and SO/sub 2/ Content, Use of Dual CO/sub 2/ Removal Units, and the Methanation Scheme. The Battelle process shows thermal efficiencies significantly lower than the most efficient processes, i.e., HYGAS, CO/sub 2/ Acceptor and BI-GAS.

  17. Combined compressed air storage-low BTU coal gasification power plant

    Science.gov (United States)

    Kartsounes, George T.; Sather, Norman F.

    1979-01-01

    An electrical generating power plant includes a Compressed Air Energy Storage System (CAES) fueled with low BTU coal gas generated in a continuously operating high pressure coal gasifier system. This system is used in coordination with a continuously operating main power generating plant to store excess power generated during off-peak hours from the power generating plant, and to return the stored energy as peak power to the power generating plant when needed. The excess coal gas which is produced by the coal gasifier during off-peak hours is stored in a coal gas reservoir. During peak hours the stored coal gas is combined with the output of the coal gasifier to fuel the gas turbines and ultimately supply electrical power to the base power plant.

  18. H/sub 2/S-removal processes for low-Btu coal gas

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, M. S.

    1979-01-01

    Process descriptions are provided for seven methods of removing H/sub 2/S from a low-Btu coal-derived gas. The processes include MDEA, Benfield, Selexol, Sulfinol, Stretford, MERC Iron Oxide, and Molecular Sieve. Each of these processes was selected as representing a particular category of gas treating (e.g., physical solvent systems). The open literature contains over 50 processes for H/sub 2/S removal, of which 35 were briefly characterized in the literature survey. Using a technical evaluation of these 35 processes, 21 were eliminated as unsuitable for the required application. The remaining 14 processes represent six categories of gas treating. A seventh category, low-temperature solid sorption, was subsequently added. The processes were qualitatively compared within their respective categories to select a representative process in each of the seven categories.

  19. Analysis of industrial markets for low and medium Btu coal gasification. [Forecasting

    Energy Technology Data Exchange (ETDEWEB)

    1979-07-30

    Low- and medium-Btu gases (LBG and MBG) can be produced from coal with a variety of 13 existing and 25 emerging processes. Historical experience and previous studies indicate a large potential market for LBG and MBG coal gasification in the manufacturing industries for fuel and feedstocks. However, present use in the US is limited, and industry has not been making substantial moves to invest in the technology. Near-term (1979-1985) market activity for LBG and MBG is highly uncertain and is complicated by a myriad of pressures on industry for energy-related investments. To assist in planning its program to accelerate the commercialization of LBG and MBG, the Department of Energy (DOE) contracted with Booz, Allen and Hamilton to characterize and forecast the 1985 industrial market for LBG and MBG coal gasification. The study draws five major conclusions: (1) There is a large technically feasible market potential in industry for commercially available equipment - exceeding 3 quadrillion Btu per year. (2) Early adopters will be principally steel, chemical, and brick companies in described areas. (3) With no additional Federal initiatives, industry commitments to LBG and MBG will increase only moderately. (4) The major barriers to further market penetration are lack of economic advantage, absence of significant operating experience in the US, uncertainty on government environmental policy, and limited credible engineering data for retrofitting industrial plants. (5) Within the context of generally accepted energy supply and price forecasts, selected government action can be a principal factor in accelerating market penetration. Each major conclusion is discussed briefly and key implications for DOE planning are identified.

  20. High-temperature turbine technology program. Turbine subsystem design report: Low-Btu gas

    Energy Technology Data Exchange (ETDEWEB)

    Horner, M.W.

    1980-12-01

    The objective of the US Department of Energy High-Temperature Turbine Technology (DOE-HTTT) program is to bring to technology readiness a high-temperature (2600/sup 0/F to 3000/sup 0/F firing temperature) turbine within a 6- to 10-year duration, Phase II has addressed the performance of component design and technology testing in critical areas to confirm the design concepts identified in the earlier Phase I program. Based on the testing and support studies completed under Phase II, this report describes the updated turbine subsystem design for a coal-derived gas fuel (low-Btu gas) operation at 2600/sup 0/F turbine firing temperature. A commercial IGCC plant configuration would contain four gas turbines. These gas turbines utilize an existing axial flow compressor from the GE product line MS6001 machine. A complete description of the Primary Reference Design-Overall Plant Design Description has been developed and has been documented. Trends in overall plant performance improvement at higher pressure ratio and higher firing temperature are shown. It should be noted that the effect of pressure ratio on efficiency is significally enhanced at higher firing temperatures. It is shown that any improvement in overall plant thermal efficiency reflects about the same level of gain in Cost of Electricity (COE). The IGCC concepts are shown to be competitive in both performance and cost at current and near-term gas turbine firing temperatures of 1985/sup 0/F to 2100/sup 0/F. The savings that can be accumulated over a thirty-year plant life for a water-cooled gas turbine in an IGCC plant as compared to a state-of-the-art coal-fired steam plant are estimated. A total of $500 million over the life of a 1000 MW plant is projected. Also, this IGCC power plant has significant environmental advantages over equivalent coal-fired steam power plants.

  1. Ultrasonic flow meter

    NARCIS (Netherlands)

    Lötters, Joost Conrad; Snijders, G.J.; Volker, A.W.F.

    2014-01-01

    The invention relates to an ultrasonic flow meter comprising a flow tube for the fluid whose flow rate is to be determined. The flow meter comprises a transmitting element for emitting ultrasonic waves, which is provided on the outer jacket of the flow tube. A receiving element, which is provided on

  2. Optical cycle power meter

    DEFF Research Database (Denmark)

    2014-01-01

    A bicycle power meter for measuring power generated when riding a bicycle, the power meter comprising a position-sensitive radiation detector (409) attachable to a component of a crank set (404) of bicycle, and a radiation source (408) attachable to the component of the crank set and configured...

  3. Ramp Metering Status in California

    Directory of Open Access Journals (Sweden)

    Zhongren Wang

    2013-12-01

    Full Text Available The purpose of this paper is to provide an update of the major improvement in terms of ramp metering design and operations in California. These updates include ramp metering policies, ramp metering development plans, ramp metering design manual, and ramp metering and system management initiatives.

  4. Peak flow meter (image)

    Science.gov (United States)

    A peak flow meter is commonly used by a person with asthma to measure the amount of air that can be ... become narrow or blocked due to asthma, peak flow values will drop because the person cannot blow ...

  5. Low-Btu coal-gasification-process design report for Combustion Engineering/Gulf States Utilities coal-gasification demonstration plant. [Natural gas or No. 2 fuel oil to natural gas or No. 2 fuel oil or low Btu gas

    Energy Technology Data Exchange (ETDEWEB)

    Andrus, H E; Rebula, E; Thibeault, P R; Koucky, R W

    1982-06-01

    This report describes a coal gasification demonstration plant that was designed to retrofit an existing steam boiler. The design uses Combustion Engineering's air blown, atmospheric pressure, entrained flow coal gasification process to produce low-Btu gas and steam for Gulf States Utilities Nelson No. 3 boiler which is rated at a nominal 150 MW of electrical power. Following the retrofit, the boiler, originally designed to fire natural gas or No. 2 oil, will be able to achieve full load power output on natural gas, No. 2 oil, or low-Btu gas. The gasifier and the boiler are integrated, in that the steam generated in the gasifier is combined with steam from the boiler to produce full load. The original contract called for a complete process and mechanical design of the gasification plant. However, the contract was curtailed after the process design was completed, but before the mechanical design was started. Based on the well defined process, but limited mechanical design, a preliminary cost estimate for the installation was completed.

  6. Conducted interference on smart meters

    NARCIS (Netherlands)

    Keyer, Cornelis H.A.; Leferink, Frank

    2017-01-01

    The increasing conducted interference caused by modern electronic equipment is causing more problems for electronic, or static, energy meters. These meters are called smart meters when equipped with a communication link, and are replacing the conventional electromechanical meters. It is known that

  7. Transformer and Meter Tester

    Science.gov (United States)

    Stoms, R. M.

    1984-01-01

    Numerically-controlled 5-axis machine tool uses transformer and meter to determine and indicate whether tool is in home position, but lacks built-in test mode to check them. Tester makes possible test, and repair of components at machine rather then replace them when operation seems suspect.

  8. Environmental and health study of a low-Btu gasifier. [Univ. of Minnesota-Duluth demonstration gasifier

    Energy Technology Data Exchange (ETDEWEB)

    Cowser, K.E.; McGurl, G.V.; Wood, R.W.

    1978-01-01

    An environmental and health, monitoring and testing plan is now being implemented at the low-Btu gasifier located on the campus of the University of Minnesota-Duluth. This is one of several project plans under consideration by the Department of Energy in conjunction with the Gasifier in Industry Demonstration program. Numerous staff of the Oak Ridge National Laboratory and Department of Energy participated in the development and review of the monitoring and testing plan which includes on-line studies, in-plant studies, and local area studies to be integrated through multidisciplinary assessments. A description is provided of the process and facilities, of the rationale for the environmental and health plan, and of the principal program components including process measurements and controls, occupational exposures and effects, environmental fate and effects, and assessments.

  9. Smart metering design and applications

    CERN Document Server

    Weranga, K S K; Chandima, D P

    2013-01-01

    Taking into account the present day trends and the requirements, this Brief focuses on smart metering of electricity for next generation energy efficiency and conservation. The contents include discussions on the smart metering concepts and existing technologies and systems as well as design and implementation of smart metering schemes together with detailed examples.

  10. Peak flow meter use - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100202.htm Peak flow meter use - Series—Peak flow meter use - part one To use the sharing ... slide 7 out of 7 Overview A peak flow meter helps you check how well your asthma ...

  11. Good standards for smart meters

    NARCIS (Netherlands)

    Hoenkamp, R.A.; Huitema, G.B.

    2012-01-01

    This paper examines what lessons can be learned from the rollout of smart meters in the Netherlands to improve the European smart meter standardization. This study is based on the case of the Dutch meter rollout which preparations started in 2005 but finally was delayed until 2011 by governmental

  12. Advanced metering techniques

    Energy Technology Data Exchange (ETDEWEB)

    Szydlowski, R.F.

    1993-01-01

    The goal of the US Department of Energy Federal Energy Management Program (FEMP) is to facilitate energy-efficiency improvements at federal facilities. This is accomplished by a balanced program of technology development, facility assessment, and use of cost-sharing procurement mechanisms. Technology development focuses upon the tools and procedures used to identify and evaluate efficiency improvements. For facility assessment, FEMP provides metering equipment and trained analysts to federal agencies exhibiting a commitment to improve energy-use efficiency. To assist in implementing energy-efficiency measures, FEMP helps federal agencies with identifying efficiency opportunities and in implementing energy-efficiency and demand-side management programs at federal sites. As the lead laboratory for FEMP, Pacific Northwest Laboratory (PNL) provides technical assistance to federal agencies to better understand and characterize energy systems. The US Army Forces Command (FORSCOM) has tasked PNL to provide technical assistance to characterize and modernize energy systems at FORSCOM installations. As part of that technical assistance, PNL performed an in-depth examination of automatic meter-reading system technologies currently available. The operating characteristics and relative merits of all the major systems were reviewed in the context of applicability to federal installations. That review is documented in this report.

  13. ATP Hydrolysis Induced Conformational Changes in the Vitamin B12 Transporter BtuCD Revealed by MD Simulations.

    Science.gov (United States)

    Pan, Chao; Weng, Jingwei; Wang, Wenning

    2016-01-01

    ATP binding cassette (ABC) transporters utilize the energy of ATP hydrolysis to uni-directionally transport substrates across cell membrane. ATP hydrolysis occurs at the nucleotide-binding domain (NBD) dimer interface of ABC transporters, whereas substrate translocation takes place at the translocation pathway between the transmembrane domains (TMDs), which is more than 30 angstroms away from the NBD dimer interface. This raises the question of how the hydrolysis energy released at NBDs is "transmitted" to trigger the conformational changes at TMDs. Using molecular dynamics (MD) simulations, we studied the post-hydrolysis state of the vitamin B12 importer BtuCD. Totally 3-μs MD trajectories demonstrate a predominantly asymmetric arrangement of the NBD dimer interface, with the ADP-bound site disrupted and the ATP-bound site preserved in most of the trajectories. TMDs response to ATP hydrolysis by separation of the L-loops and opening of the cytoplasmic gate II, indicating that hydrolysis of one ATP could facilitate substrate translocation by opening the cytoplasmic end of translocation pathway. It was also found that motions of the L-loops and the cytoplasmic gate II are coupled with each other through a contiguous interaction network involving a conserved Asn83 on the extended stretch preceding TM3 helix plus the cytoplasmic end of TM2/6/7 helix bundle. These findings entail a TMD-NBD communication mechanism for type II ABC importers.

  14. Micro-gen metering solutions

    Energy Technology Data Exchange (ETDEWEB)

    Elland, J.; Dickson, J.; Cranfield, P.

    2003-07-01

    This report summarises the results of a project to investigate the regulation of domestic electricity metering work and identify the most economic options for micro-generator installers to undertake work on electricity meters. A micro-generation unit is defined as an energy conversion system converting non-electrical energy into electrical energy and can include technologies such as photovoltaic systems, small-scale wind turbines, micro-hydroelectric systems, and combined heat and power systems. Details of six tasks are given and cover examination of the existing framework and legal documentation for metering work, the existing technical requirements for meter operators, meter operator personnel accreditation, appraisal of options for meter changes and for micro-generation installation, document change procedures, industry consultation, and a review of the costs implications of the options.

  15. Well profile meter

    Energy Technology Data Exchange (ETDEWEB)

    Zhivotovskiy, Iz.Z.; Iskenderov, V.G.; Perelman, G.Ya.

    1982-01-01

    A well profile meter is proposed which contains in-series connected measurement levers, remote measuring system, signal summators of lever pairs arranged in one vertical plain, and recorders, one of which recorded the operational, and the other all the measurement information. It is distinguished by the fact that in order to exclude ambiguity in determining the intervals of possible groove formation and surplus information recorded by the recorder of all measurement information, it is equipped with threshold blocks for isolating signals corresponding to the minimum and maximum diameters, storage circuit, accumulator, control circuit, synchronization circuit and input keys of the recorder of the entire measurement information. In this case the inlet of the synchronization circuit is connected to the remote measurement system, and one of the outlets is connected to the parallel included inlets of the threshold blocks for isolating signals corresponding to the minimum and maximum diameters. The other outlet of the synchronization circuit is connected to the parallel included inlets of their storage circuit, accumulator and control circuit. The inlet keys of the recorder of all the measurement information are connected by their inlets to the inlets of the summator of the lever pairs and the outlet of the control circuit. The outlets are connected to the recorder of all measurement information, the outlet of the threshold block of signal isolation corresponding to the maximum diameter, through the storage circuit is connected to 1 of the inlets of the recorder of operational information. The outlet of the threshold block of signal isolation corresponding to the minimum diameter is connected through the accumulator to the other inlet of the recorder of operational information, while the outlets of the storage circuit and the accumulator are connected to the inlets of the control circuit.

  16. System and process for the abatement of casting pollution, reclaiming resin bonded sand, and/or recovering a low Btu fuel from castings

    Science.gov (United States)

    Scheffer, K.D.

    1984-07-03

    Air is caused to flow through the resin bonded mold to aid combustion of the resin binder to form a low Btu gas fuel. Casting heat is recovered for use in a waste heat boiler or other heat abstraction equipment. Foundry air pollutis reduced, the burned portion of the molding sand is recovered for immediate reuse and savings in fuel and other energy is achieved. 5 figs.

  17. Smart Metering System for Microgrids

    DEFF Research Database (Denmark)

    Palacios-Garcia, Emilio; Guan, Yajuan; Savaghebi, Mehdi

    2015-01-01

    Smart meters are the cornerstone in the new conception of the electrical network or Smart Grid (SG), providing detailed information about users' energy consumption and allowing the suppliers to remotely collect data for billing. Nevertheless, their features are not only useful for the energy...... will expose an example of Smart Meters integration in a Microgrid scenario, which is the Intelligent Microgrid Lab of Aalborg University (AAU). To do this, first the installation available in the Microgrid Lab will be introduced. Then, three different test scenarios and their respective results...... will be presented, regarding the capabilities of this system and the advantages of integration the Smart Meters information in the Microgrid control....

  18. Streamlining Smart Meter Data Analytics

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Nielsen, Per Sieverts

    2015-01-01

    -economic metrics such as the geographic information of meters, the information about users and their property, geographic location and others, which make the data management very complex. On the other hand, data-mining and the emerging cloud computing technologies make the collection, management, and analysis...... of the so-called big data possible. This can improve energy management, e.g., help utilities improve the management of energy and services, and help customers save money. As this regard, the paper focuses on building an innovative software solution to streamline smart meter data analytic, aiming at dealing...... with the complexity of data processing and data analytics. The system offers an information integration pipeline to ingest smart meter data; scalable data processing and analytic platform for pre-processing and mining big smart meter data sets; and a web-based portal for visualizing data analytics results. The system...

  19. Smart meters in smart manufacturing

    OpenAIRE

    Martín Rubio, Irene; Florence Sandoval, Antonio; Gonzalez Sanchez, Elena; Andina de la Fuente, Diego

    2016-01-01

    The extent of change in business process and smart manufacturing usage should be taken into account in every energy efficiency project in industries. A significant part of smart metering success depends upon making the business processes more systematic. Smart manufacturing in the dramatically intensified and pervasive application of networked information-based technologies through the manufacturing and supply chain enterprise. There is no doubt that the deployment os smart meters involves ...

  20. Healthcare Energy Metering Guidance (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2011-07-01

    This brochure is intended to help facility and energy managers plan and prioritize investments in energy metering. It offers healthcare-specific examples of metering applications, benefits, and steps that other health systems can reproduce. It reflects collaborative input from the U.S. Department of Energy national laboratories and the health system members of the DOE Hospital Energy Alliance's Benchmarking and Measurement Project Team.

  1. Tb3+-cleavage assays reveal specific Mg2+ binding sites necessary to pre-fold the btuB riboswitch for AdoCbl binding

    Science.gov (United States)

    Choudhary, Pallavi K.; Gallo, Sofia; Sigel, Roland K. O.

    2017-03-01

    Riboswitches are RNA elements that bind specific metabolites in order to regulate the gene expression involved in controlling the cellular concentration of the respective molecule or ion. Ligand recognition is mostly facilitated by Mg2+ mediated pre-organization of the riboswitch to an active tertiary fold. To predict these specific Mg2+ induced tertiary interactions of the btuB riboswitch from E. coli, we here report Mg2+ binding pockets in its aptameric part in both, the ligand-free and the ligand-bound form. An ensemble of weak and strong metal ion binding sites distributed over the entire aptamer was detected by terbium(III) cleavage assays, Tb3+ being an established Mg2+ mimic. Interestingly many of the Mn+ (n = 2 or 3) binding sites involve conserved bases within the class of coenzyme B12-binding riboswitches. Comparison with the published crystal structure of the coenzyme B12 riboswitch of S. thermophilum aided in identifying a common set of Mn+ binding sites that might be crucial for tertiary interactions involved in the organization of the aptamer. Our results suggest that Mn+ binding at strategic locations of the btuB riboswitch indeed facilitates the assembly of the binding pocket needed for ligand recognition. Binding of the specific ligand, coenzyme B12 (AdoCbl), to the btuB aptamer does however not lead to drastic alterations of these Mn+ binding cores, indicating the lack of a major rearrangement within the three-dimensional structure of the RNA. This finding is strengthened by Tb3+ mediated footprints of the riboswitch's structure in its ligand-free and ligand-bound state indicating that AdoCbl indeed induces local changes rather than a global structural rearrangement.

  2. Arduino based radiation survey meter

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, Nur Aira Abd, E-mail: nur-aira@nm.gov.my; Lombigit, Lojius; Abdullah, Nor Arymaswati; Azman, Azraf; Dolah, Taufik; Jaafar, Zainudin; Mohamad, Glam Hadzir Patai; Ramli, Abd Aziz Mhd; Zain, Rasif Mohd; Said, Fazila; Khalid, Mohd Ashhar; Taat, Muhamad Zahidee [Malaysian Nuclear Agency, 43000, Bangi, Selangor (Malaysia); Muzakkir, Amir [Sinaran Utama Teknologi Sdn Bhd, 43650, Bandar Baru Bangi, Selangor (Malaysia)

    2016-01-22

    This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr{sup −1}). Conversion factor (CF) value for conversion of CPM to μSvhr{sup −1} determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The survey meter measurement results are found to be linear for dose rates below 3500 µSv/hr.

  3. Automated monitoring of milk meters

    NARCIS (Netherlands)

    Mol, de R.M.; Andre, G.

    2009-01-01

    Automated monitoring might be an alternative for periodic checking of electronic milk meters. A computer model based on Dynamic Linear Modelling (DLM) has been developed for this purpose. Two situations are distinguished: more milking stands in the milking parlour and only one milking stand in the

  4. MULTICHANNEL DISTRIBUTION METER: A VERITABLE ...

    African Journals Online (AJOL)

    eobe

    replaced by their digital counterparts, which come with the capability of automatic disconnection. Yet, in every other ... neutral lines to detect pilferages in digital meters, while a light emitting diode (LED), a light dependent ..... Conditions in a Developing Economy”, Nigerian. Journal of Technology, Vol. 6 No. 1 September 1982.

  5. Smart metering. Conformance tests for electricity meters; Smart Metering. Konformitaetstests an Stromzaehlern

    Energy Technology Data Exchange (ETDEWEB)

    Bormann, Matthias; Pongratz, Siegfried [VDE Pruef- und Zertifizierungsinstitut, Offenbach (Germany)

    2012-07-01

    Introduction of communication technologies into today's energy network enables the interworking between the domains of smart metering, smart grid, smart home and e-mobility as well as the creation and provisioning of new innovative services such as efficient load adjustment. Due to this convergence the new energy networks are becoming increasingly complex. Ensuring the interworking between all network elements (e.g. electricity meters, gateways) in these smart energy networks is of utmost importance. To this end conformance and interoperability tests have to be defined to ensure that services work as expected. (orig.)

  6. Federal Building Metering Guidance (per 42 U.S.C. 8253(e), Metering of Energy Use)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-11-01

    Guidance defines which federal buildings are appropriate to meter, provides metering prioritization recommendations for agencies with limited resources, and discusses the requirement for agencies to submit metering implementation plans to the U.S. Department of Energy.

  7. 77 FR 40586 - Draft NIST Interagency Report (NISTIR) 7823, Advanced Metering Infrastructure Smart Meter...

    Science.gov (United States)

    2012-07-10

    ... 7823 includes numerous stakeholders in the Smart Grid space, particularly customers, Smart Meter... National Institute of Standards and Technology Draft NIST Interagency Report (NISTIR) 7823, Advanced Metering Infrastructure Smart Meter Upgradeability Test Framework; Request for Comments AGENCY: National...

  8. Smart Metering System for Microgrids

    OpenAIRE

    Palacios-Garcia, Emilio; Guan, Yajuan; Savaghebi, Mehdi; Quintero, Juan Carlos Vasquez; Guerrero, Josep M.; Moreno-Munoz, Antonio; Ipsen, Brian S.

    2015-01-01

    Smart meters are the cornerstone in the new conception of the electrical network or Smart Grid (SG), providing detailed information about users' energy consumption and allowing the suppliers to remotely collect data for billing. Nevertheless, their features are not only useful for the energy suppliers, but they can also play a big role in the control of the Microgrid since the recorded power and energy profiles can be integrated in energy management systems (EMS). In addition, basic power qua...

  9. Commercial low-Btu coal-gasification plant. Feasibility study: General Refractories Company, Florence, Kentucky. Volume I. Project summary. [Wellman-Galusha

    Energy Technology Data Exchange (ETDEWEB)

    None

    1981-11-01

    In response to a 1980 Department of Energy solicitation, the General Refractories Company submitted a Proposal for a feasibility study of a low Btu gasification facility for its Florence, KY plant. The proposed facility would substitute low Btu gas from a fixed bed gasifier for natural gas now used in the manufacture of insulation board. The Proposal from General Refractories was prompted by a concern over the rising costs of natural gas, and the anticipation of a severe increase in fuel costs resulting from deregulation. The proposed feasibility study is defined. The intent is to provide General Refractories with the basis upon which to determine the feasibility of incorporating such a facility in Florence. To perform the work, a Grant for which was awarded by the DOE, General Refractories selected Dravo Engineers and Contractors based upon their qualifications in the field of coal conversion, and the fact that Dravo has acquired the rights to the Wellman-Galusha technology. The LBG prices for the five-gasifier case are encouraging. Given the various natural gas forecasts available, there seems to be a reasonable possibility that the five-gasifier LBG prices will break even with natural gas prices somewhere between 1984 and 1989. General Refractories recognizes that there are many uncertainties in developing these natural gas forecasts, and if the present natural gas decontrol plan is not fully implemented some financial risks occur in undertaking the proposed gasification facility. Because of this, General Refractories has decided to wait for more substantiating evidence that natural gas prices will rise as is now being predicted.

  10. Capacitive level meter for liquid hydrogen

    OpenAIRE

    Matsumoto, Koichi; Sobue, Masamitsu; Asamoto, Kai; Nishimura, Yuta; Abe, Satoshi; Numazawa, Takenori

    2011-01-01

    A capacitive level meter working at low temperatures was made to use in magnetic refrigerator for hydrogen liquefaction. The liquid level was measured from the capacitance between parallel electrodes immersed in the liquid. The meter was tested for liquid nitrogen, hydrogen, and helium. The operation was successful using an AC capacitance bridge. The estimated sensitivity of the meter is better than 0.2 mm for liquid hydrogen. The meter also worked with pressurized hydrogen. © 2010.

  11. Multitasking metering enhances generation, transmission operations

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, E.

    2008-11-15

    The Dairyland Power Cooperative (DPC) which operates from La Crosse, Wisconsin has the capacity to generate and transmit 1000 MW of power to 25 member cooperatives and 20 municipalities who serve over 500,000 customers. When DPC was experiencing diminished service within its analog cellular-based data communications system, it was presented with an opportunity to install a new automated telecommunications system that would provide secure collection of meter readings from all of its substations. DPC decided to evaluate an advanced multifunctional digital meter from Schweitzer Engineering Laboratories (SEL). The SEL-734 Revenue Metering System offers complete instantaneous metering functions, including voltages, currents, power, energy and power factor. Other capabilities include predictive demand, time-of-use metering, automatic voltage monitoring, harmonics metering and synchrophasor measurement. From a metering perspective, DPC wanted to perform daily load profiles and interval-by-interval metering of their delivery points for billing purposes. They also wanted to provide real-time monitoring of electricity being delivered for both generation and transmission purposes and to make that information available to a distribution SCADA system for their members. The SEL-734 Revenue Meter was well suited to those needs. The SEL-734 provides very high-accuracy energy metering, load profile data collection, instantaneous power measurements, power quality monitoring, and communicates simultaneously over a modem, serial ports, and wide area networks (WAN). The meter is backed with a ten-year warranty as well as field support engineers. 5 figs.

  12. Discussion series on PURPA related topics: metering

    Energy Technology Data Exchange (ETDEWEB)

    Sturgeon, J I

    1980-08-01

    Time-differentiated metering of electricity consumption and demand is required in both rate-structure experimentation and the implementation of most time-of-use rate designs. Time-differentiated metering takes three major forms: multi-register watthour meters, magnetic-tape recording meters, and remote automatic meter-reading systems. The majority of projects selected magnetic-tape meters for their flexibility with respect to rate structure, load-survey capabilities, and ready availability. The small-scale, experimental nature of the projects reduced the significance of the large difference in per-unit cost and operational/maintenance complexity between this form of metering and the multi-register form. Magnetic-tape meters are not likely candidates for system-wide implementation of time-differentiated metering. Automatic remote-meter-reading systems were not adequately available during the project years; those projects attempting to use these were unable to bring them to full operational status before project termination, due to the many problems of design, quality control, and equipment acquisition encountered. Delays in acquisition and problems of quality control also followed the selection of magnetic-tape meters and multi-register meters by a number of the projects. Though less complex than automatic remote-reading systems, these technologies are still new and more complex than standard watthour metering. Thus, both equipment vendors and utilities encountered numerous problems in getting properly functioning meters to the service entrances on time. A variety of factors contributed to installation delays, including unforeseen space limitations, incompatible wiring, problems of task organization, and customer reluctance.

  13. EVALUATION OF INTERNALLY STAGED COAL BURNERS AND SORBENT JET AERODYNAMICS FOR COMBINED SO2/NOX CONTROL IN UTILITY BOILERS; VOLUME 2. TESTING IN A 100 MILLION BTU/HR EXPERIMENTAL FURNACE

    Science.gov (United States)

    The report givesresults of100 million Btu/hr (29 MWt) experimental furnace to explore methods for achieving effective S02 removal in a coalfired utility boiler using calcium-based sorbents, through appropriate selection of injection location and injector design/operating paramete...

  14. Automated on-line determination of PPB levels of sodium and potassium in low-Btu coal gas and fluidized bed combustor exhaust by atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Haas, W.J. Jr.; Eckels, D.E.; Kniseley, R.N.; Fassel, V.A.

    1981-01-01

    The Morgantown Energy Technology Center (METC), US Department of Energy, is involved in the development of processes and equipment for production of low-Btu gas from coal and for fluidized bed combustion of coal. The ultimate objective is large scale production of electricity using high temperature gas turbines. Such turbines, however, are susceptible to accelerated corrosion and self-destruction when relatively low concentrations of sodium and potassium are present in the driving gas streams. Knowledge and control of the concentrations of those elements, at part per billion levels, are critical to the success of both the gas cleanup procedures that are being investigated and the overall energy conversion processes. This presentation describes instrumentation and procedures developed at the Ames Laboratory for application to the problems outlined above and results that have been obtained so far at METC. The first Ames instruments, which feature an automated, dual channel flame atomic emission spectrometer, perform the sodium and potassium determinations simultaneously, repetitively, and automatically every two to three minutes by atomizing and exciting a fraction of the subject gas sample stream in either an oxyhydrogen flame or a nitrous oxide-acetylene flame. The analytical results are printed and can be transmitted simultaneously to a process control center.

  15. Simplified Processing Method for Meter Data Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, Kimberly M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Colotelo, Alison H. A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Downs, Janelle L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Ham, Kenneth D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Henderson, Jordan W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Montgomery, Sadie A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Vernon, Christopher R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Parker, Steven A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-11-01

    Simple/Quick metered data processing method that can be used for Army Metered Data Management System (MDMS) and Logistics Innovation Agency data, but may also be useful for other large data sets. Intended for large data sets when analyst has little information about the buildings.

  16. FLOW METERS WITH VERY GOOD PERFORMANCES

    Directory of Open Access Journals (Sweden)

    Mircea Dimitrie CAZACU

    2011-11-01

    Full Text Available We present the theoretical calculus of a patented flow meter, concerning such the thermodynamic and aerodynamic calculus, as well as the offered precision to measure the flow of the air in any meteorological conditions. In the same time we remark that the proposed flow meter, by its positioning, has not loss of head.

  17. A prepaid meter using mobile communication

    African Journals Online (AJOL)

    user

    prepaid card remotely through mobile communication based on customer requests. A prior billing is bound to do away with the problems of unpaid bills and human error in meter readings, thereby ensuring justified revenue for the utility. The proposed prepaid meter is implemented in a software model and Matlab has been ...

  18. Bandwidth Analysis of Smart Meter Network Infrastructure

    DEFF Research Database (Denmark)

    Balachandran, Kardi; Olsen, Rasmus Løvenstein; Pedersen, Jens Myrup

    2014-01-01

    Advanced Metering Infrastructure (AMI) is a net-work infrastructure in Smart Grid, which links the electricity customers to the utility company. This network enables smart services by making it possible for the utility company to get an overview of their customers power consumption and also control...... to utilize smart meters and which existing broadband network technologies can facilitate this smart meter service. Initially, scenarios for smart meter infrastructure are identified. The paper defines abstraction models which cover the AMI scenarios. When the scenario has been identified a general overview...... of the bandwidth requirements are analysed. For this analysis the assumptions and limitations are defined. The results obtained by the analysis show, that the amount of data collected and transferred by a smart meter is very low compared to the available bandwidth of most internet connections. The results show...

  19. Simple meters get smart? Cost benefit analysis of smart metering infrastructure; Domme meters worden slim? Kosten-batenanalyse slimme meetinfrastructuur

    Energy Technology Data Exchange (ETDEWEB)

    Van Gerwen, R.J.F.; Jaarsma, S.A.; Koenis, F.T.C. [KEMA T and D Consulting, Arnhem (Netherlands)

    2005-08-15

    The Dutch Ministry of Economic Affairs requested a cost-benefit analysis of the large scale introduction of a smart meter infrastructure for gas and electricity consumption by small consumers. The questions asked in the study need to be answered in order to enable a well-founded evaluation of the implementation of smart meters. [mk]. [Dutch] Het Ministerie van Economische Zaken heeft een kosten-batenanalyse laten uitvoeren naar de grootschalige introductie van een slimme meetinfrastructuur voor gas- en elektriciteitsverbruik door kleinverbruikers. De in het onderzoek gestelde vragen moeten beantwoord worden om een goed gefundeerd oordeel te kunnen geven over de invoering van slimme meters.

  20. Soft-sensing, non-intrusive multiphase flow meter

    NARCIS (Netherlands)

    Wrobel, K.; Schiferli, W.

    2009-01-01

    For single phase flow meters more and better non-intrusive or even clamp-on meters become available. This allows for a wider use of meters and for easier flow control. As the demand for multiphase meters is increasing, the current aim is to develop a non-intrusive multiphase flow meter. The

  1. EPA Region 1 - Valley Depth in Meters

    Data.gov (United States)

    U.S. Environmental Protection Agency — Raster of the Depth in meters of EPA-delimited Valleys in Region 1. Valleys (areas that are lower than their neighbors) were extracted from a Digital Elevation Model...

  2. EMMNet: sensor networking for electricity meter monitoring.

    Science.gov (United States)

    Lin, Zhi-Ting; Zheng, Jie; Ji, Yu-Sheng; Zhao, Bao-Hua; Qu, Yu-Gui; Huang, Xu-Dong; Jiang, Xiu-Fang

    2010-01-01

    Smart sensors are emerging as a promising technology for a large number of application domains. This paper presents a collection of requirements and guidelines that serve as a basis for a general smart sensor architecture to monitor electricity meters. It also presents an electricity meter monitoring network, named EMMNet, comprised of data collectors, data concentrators, hand-held devices, a centralized server, and clients. EMMNet provides long-distance communication capabilities, which make it suitable suitable for complex urban environments. In addition, the operational cost of EMMNet is low, compared with other existing remote meter monitoring systems based on GPRS. A new dynamic tree protocol based on the application requirements which can significantly improve the reliability of the network is also proposed. We are currently conducting tests on five networks and investigating network problems for further improvements. Evaluation results indicate that EMMNet enhances the efficiency and accuracy in the reading, recording, and calibration of electricity meters.

  3. Informatics Solutions for Smart Metering Systems Integration

    Directory of Open Access Journals (Sweden)

    Simona-Vasilica OPREA

    2015-01-01

    Full Text Available In this paper different aspects regarding smart metering systems integration have been depicted. Smart metering systems, renewable energy sources integration and advanced tariff systems implementation require informatics solution that could automatically collect and process data, forecast the behavior of electricity consumers, analyze trends regarding electricity prices, optimize the consumption of consumers, provide friendly interfaces, etc. They are advanced technologies that represent solutions for insufficient conventional primary energy sources, gas emissions, dependency on energy sources located outside European Union and issues related to energy efficiency. This paper mainly describes several informatics solutions correlated with operational requirements for smart metering system and our proposal for simplified architecture of smart metering systems, with three distinct levels (base level, middle level and top level and load profile calculation methods.

  4. SPOT Controlled Image Base 10 meter

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — SPOT Controlled Image Base 10 meter (CIB-10) is a collection of orthorectified panchromatic (grayscale) images. The data were acquired between 1986 and 1993 by the...

  5. New consumer services provided by smart metering

    Directory of Open Access Journals (Sweden)

    Daminov Ildar

    2015-01-01

    Full Text Available This paper focuses on the issues of smart metering market and considers different services provided by smart metering from consumer point of view. Firstly, smart metering deployment challenges emerging and conventional tariffs, which modify a consumer behavior and thus, the entire electric energy market can be optimized since the customer is motivated to consume less energy. Secondly, the authors illustrate changes in electricity quality, which have an impact on consumer relations with utility. Additionally, two main indices of grid resilience – SAIDI and SAIFI – are exemplified to reveal the improvement potential of smart metering implementation in certain regions of Russia that also influence the consumer. Finally, in-home display and privacy problem directly reflect the consumer’s behavior, thus the private life rights should not be violated as they are guaranteed by law.

  6. VT USGS NED DEM (10 meter) - statewide

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) This dataset is derived from the multi-resolution National Elevation Dataset (NED), at resolutions of both 1/3 arc-second (approx. 10 meters) and...

  7. EMMNet: Sensor Networking for Electricity Meter Monitoring

    Directory of Open Access Journals (Sweden)

    Zhi-Ting Lin

    2010-06-01

    Full Text Available Smart sensors are emerging as a promising technology for a large number of application domains. This paper presents a collection of requirements and guidelines that serve as a basis for a general smart sensor architecture to monitor electricity meters. It also presents an electricity meter monitoring network, named EMMNet, comprised of data collectors, data concentrators, hand-held devices, a centralized server, and clients. EMMNet provides long-distance communication capabilities, which make it suitable suitable for complex urban environments. In addition, the operational cost of EMMNet is low, compared with other existing remote meter monitoring systems based on GPRS. A new dynamic tree protocol based on the application requirements which can significantly improve the reliability of the network is also proposed. We are currently conducting tests on five networks and investigating network problems for further improvements. Evaluation results indicate that EMMNet enhances the efficiency and accuracy in the reading, recording, and calibration of electricity meters.

  8. EMMNet: Sensor Networking for Electricity Meter Monitoring

    Science.gov (United States)

    Lin, Zhi-Ting; Zheng, Jie; Ji, Yu-Sheng; Zhao, Bao-Hua; Qu, Yu-Gui; Huang, Xu-Dong; Jiang, Xiu-Fang

    2010-01-01

    Smart sensors are emerging as a promising technology for a large number of application domains. This paper presents a collection of requirements and guidelines that serve as a basis for a general smart sensor architecture to monitor electricity meters. It also presents an electricity meter monitoring network, named EMMNet, comprised of data collectors, data concentrators, hand-held devices, a centralized server, and clients. EMMNet provides long-distance communication capabilities, which make it suitable suitable for complex urban environments. In addition, the operational cost of EMMNet is low, compared with other existing remote meter monitoring systems based on GPRS. A new dynamic tree protocol based on the application requirements which can significantly improve the reliability of the network is also proposed. We are currently conducting tests on five networks and investigating network problems for further improvements. Evaluation results indicate that EMMNet enhances the efficiency and accuracy in the reading, recording, and calibration of electricity meters. PMID:22163551

  9. Comparison of five portable peak flow meters

    Directory of Open Access Journals (Sweden)

    Glaucia Nency Takara

    2010-01-01

    Full Text Available OBJECTIVE: To compare the measurements of spirometric peak expiratory flow (PEF from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. METHODS: Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (p<0.05, Spearman's correlation test and Bland-Altman's agreement test. RESULTS: The median and interquartile ranges for the spirometric values and the Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® meters were 428 (263-688 L/min, 450 (350-800 L/min, 420 (310-720 L/min, 380 (300-735 L/min, 400 (310-685 L/min and 415 (335-610 L/min, respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone® (p<0.001 and Galemed ® (p<0.01 meters. There was no agreement between the spirometric values and the five PEF meters. CONCLUSIONS: The results suggest that the values recorded from Galemed® meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone® meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  10. Comparison of five portable peak flow meters.

    Science.gov (United States)

    Takara, Glaucia Nency; Ruas, Gualberto; Pessoa, Bruna Varanda; Jamami, Luciana Kawakami; Di Lorenzo, Valéria Amorim Pires; Jamami, Mauricio

    2010-05-01

    To compare the measurements of spirometric peak expiratory flow (PEF) from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone, Assess, Galemed, Personal Best and Vitalograph peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (p<0.05), Spearman's correlation test and Bland-Altman's agreement test. The median and interquartile ranges for the spirometric values and the Air Zone, Assess, Galemed, Personal Best and Vitalograph meters were 428 (263-688 L/min), 450 (350-800 L/min), 420 (310-720 L/min), 380 (300-735 L/min), 400 (310-685 L/min) and 415 (335-610 L/min), respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone(R) (p<0.001) and Galemed (p<0.01) meters. There was no agreement between the spirometric values and the five PEF meters. The results suggest that the values recorded from Galemed meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  11. Capacitive level meter for liquid rare gases

    Science.gov (United States)

    Sawada, R.; Kikuchi, J.; Shibamura, E.; Yamashita, M.; Yoshimura, T.

    2003-08-01

    An international project to search μ→eγ decay includes the use of a liquid xenon gamma ray detector. So, a liquid level meter working at a low temperature with low outgassing is needed and the prototype is constructed. The meter shows the liquid level by measuring the capacitance between electrodes with small intervals immersed in the liquid. The operation was successful with the estimated precision of 1 mm in RMS or better.

  12. Intelligent Metering for Urban Water: A Review

    Directory of Open Access Journals (Sweden)

    Rodney Stewart

    2013-07-01

    Full Text Available This paper reviews the drivers, development and global deployment of intelligent water metering in the urban context. Recognising that intelligent metering (or smart metering has the potential to revolutionise customer engagement and management of urban water by utilities, this paper provides a summary of the knowledge-base for researchers and industry practitioners to ensure that the technology fosters sustainable urban water management. To date, roll-outs of intelligent metering have been driven by the desire for increased data regarding time of use and end-use (such as use by shower, toilet, garden, etc. as well as by the ability of the technology to reduce labour costs for meter reading. Technology development in the water sector generally lags that seen in the electricity sector. In the coming decade, the deployment of intelligent water metering will transition from being predominantly “pilot or demonstration scale” with the occasional city-wide roll-out, to broader mainstream implementation. This means that issues which have hitherto received little focus must now be addressed, namely: the role of real-time data in customer engagement and demand management; data ownership, sharing and privacy; technical data management and infrastructure security, utility workforce skills; and costs and benefits of implementation.

  13. A Light-Weight Metering File System for Sustainable Real-Time Meter Data Management

    Directory of Open Access Journals (Sweden)

    Gangman Yi

    2014-09-01

    Full Text Available A real-time smart metering system has strict requirements, since every piece of data gathered from various meters every hour is of importance, and each component consisting of metering infrastructure should be sustainable. Therefore, it is necessary to efficiently manage the meter data set in smart metering networks as well as in a server. Therefore, we propose a dedicated file system, a LIght-weight Metering File System (LIMFS, which is capable of not only efficiently storing and searching meter data but also performing distributed fault-tolerant meter data management for real-time smart meter devices. The proposed LIMFS exploits accumulated data sliding storage (ADSS for lost data recovery and latest-first error-ignorant data management (LEDM to reduce memory wastage, coping with dynamic report interval. Experimental results demonstrate that LIMFS has as a small enough overhead to be considered negligible, and provides flexible memory capacity according to dynamic report interval, in spite of lost data recovery functionality.

  14. Smart Card Payment metering gas and electricity

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D.L. [Landis and Gyr (United Kingdom) Ltd., Telford, (United Kingdom); Kriby, R. [Midlands Electricity plc, Kingswinford, (United Kingdom)

    1995-12-31

    Utilities, both gas and electricity, require and operate a variety of regular payment facilities. The range used by any particular utility is primarily a result of history and usually reflects the maturity of customer car and/or regulatory policies. This paper outlines the use of smart card metering, not to be confused with pre-payment metering, which establishes an enhanced level of service to both the customer and utility through the implementation of a simple 2 way communication system. The infrastructure of the smart card system is similar to that used for a token based system, with the smart card used to replace the token for credit transfer to the meter. It involves the use of a customer card which is credited from a Point of Sale (POS), along with the latest tariff details and any messages specific for that customer. These in turn are transferred to the meter when the card is inserted. The current meter readings, readings taken at a particular time and date, and meter status messages are written back to the card for transfer to the POS when credit is next purchased. In the future this infrastructure will be needed irrespective of advances in metering technology, and the Smart card is a secure and convenient way of ensuring correct customer identification and integrity of data. Possibilities are envisaged to extend the use of the system into other payment areas as well as being able to support innovative payment methods in the future. The response from customers, regulatory and welfare bodies, and the staff of the utility is extremely positive and the future of payment systems is considered to be secure in smart card technology. (author).

  15. Anti-Theft Automatic Metering Interface

    Directory of Open Access Journals (Sweden)

    Abhijeet Das

    2015-08-01

    Full Text Available Abstract Electricity is now more than a necessity and its need is increasing day by day resulting in power theft and power scarcity. The purpose of this project is to provide automatic control and monitoring of the Domestic Energy Meter enabling the Electricity Department to read meter readings without anyone visiting each house and also prevent electricity theft .This can be achieved by the use of a Microcontroller Unit that continuously monitors and records the Energy Meter readings in its permanent memory location. This system also makes use of a GSM module for remote monitoring and control of Energy Meter with the help of an interfacing circuitry. The Microcontroller based system continuously records the readings and the live meter reading can be sent to the Electricity department after a count period or on request. This system also can be used to disconnect the power supply to the house in case of non-payment of electricity bills. The Substation will be the receiving end. The data received is fed to a microcontroller at the Substation which will automatically calculate the bill based on tariff provider and display it.

  16. Privacy friendly aggregation of smart meter readings, even when meters crash

    NARCIS (Netherlands)

    Hoepman, J.H.

    2017-01-01

    A well studied privacy problem in the area of smart grids is the question of how to aggregate the sum of a set of smart meter readings in a privacy friendly manner, i.e., in such a way that individual meter readings are not revealed to the adversary. Much less well studied is how to deal with

  17. An evaporation based digital microflow meter

    Science.gov (United States)

    Nie, C.; Frijns, A. J. H.; Mandamparambil, R.; Zevenbergen, M. A. G.; den Toonder, J. M. J.

    2015-11-01

    In this work, we present a digital microflow meter operating in the range 30-250 nl min-1 for water. The principle is based on determining the evaporation rate of the liquid via reading the number of wetted pore array structures in a microfluidic system, through which continuous evaporation takes place. A proof-of-principle device of the digital flow meter was designed, fabricated, and tested. The device was built on foil-based technology. In the proof-of-principle experiments, good agreement was found between set flow rates and the evaporation rates estimated from reading the number of wetted pore structures. The measurement range of the digital flow meter can be tuned and extended in a straightforward manner by changing the pore structure of the device.

  18. Coordinated Ramp Metering and Intersection Signal Control

    Directory of Open Access Journals (Sweden)

    Dongyan Su

    2014-06-01

    Full Text Available The operations of freeway ramp metering and urban traffic network signal control are independent in most areas. Such situation may cause some conflict between traffic streams of the two subsystems, or, at least, their dynamic interactions have not been taken into account from an overall system viewpoint. Traffic performance can be improved if the controls of these two subnetworks are integrated. This paper proposes a novel signal control strategy for the feeding intersection and a coordination strategy for integrating it with the corresponding freeway onramp metering. UP ALINEA with queue-overwrite is used for the ramp metering. A signal optimization, which takes into account the available ramp space and traffic demand, is developed for intersection signal control. A calibrated micro-simulation is used to compare the proposed control/coordination strategies and current control plans in the field. Simulation result shows that, even though the overall system performance only gets a marginal improvement, intersection delay reduces significantly.

  19. IMPORTANT: Fluke is recalling Digital Clamp Meters

    CERN Multimedia

    2013-01-01

    Fluke is voluntarily recalling four models of Digital Clamp Meters: Fluke 373, 374, 375 and 376. If you own one of these clamp meters, please stop using it and send it back to Fluke for repair even if you have not experienced problems.   Description of the problem: "The printed circuit assembly may not be properly fastened to the test lead input jack. This may result in inaccurate voltage readings, including a low or no-voltage reading on a circuit energised with a hazardous voltage, presenting a shock, electrocution or thermal burn hazard." To determine if your clamp meter is affected by this recall notice, and for more information, click here.

  20. Liquid metal Flow Meter - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, C.; Hoogendoom, S.; Hudson, B.; Prince, J.; Teichert, K.; Wood, J.; Chase, K.

    2007-01-30

    Measuring the flow of liquid metal presents serious challenges. Current commercially-available flow meters use ultrasonic, electromagnetic, and other technologies to measure flow, but are inadequate for liquid metal flow measurement because of the high temperatures required by most liquid metals. As a result of the reactivity and high temperatures of most liquid metals, corrosion and leakage become very serious safety concerns. The purpose of this project is to develop a flow meter for Lockheed Martin that measures the flow rate of molten metal in a conduit.

  1. Design and construction of portable survey meter

    Science.gov (United States)

    Singseeta, W.; Thong-aram, D.; Pencharee, S.

    2017-09-01

    This work was aimed to design and construction of portable survey meter for radiation dose measuring. The designed system consists of 4 main parts consisting of low voltage power supply, radiation detection, radiation measurement and data display part on android phone. The test results show that the ripple voltage of low voltage power supply is less than 1%, the maximum integral counts are found to be 104 counts per second and the maximum distance of wireless commination between the server and the client is about 10 meter. It was found that the developed system had small size and light weight for portable instrument.

  2. A comparative study on the metering accuracy for given installation conditions of metering facility

    Energy Technology Data Exchange (ETDEWEB)

    Her, Jae Young; Lee, Seung Jun; Ha, Young Cheol; Ahn, Seung Hee; Lee, Cheol Gu [R and D Center, Korea Gas Co., (Korea)

    1999-12-01

    The object of this study is to improve metering facilities of Korea Gas Corporation(KOGAS) metering station which are being operated in unfavorable straight pipe length condition (metropolitan area). For experiment, a test facilities was modeled based on Dogsan metering station (one of KOGAS metering stations) which has the most unfavorable conditions in metropolitan area. The test facilities was set up in Jungdong metering station (one of KOGAS metering stations) supplying natural gas to a power plant and city gas companies. The tests were performed with flowconditioner which was installed in the former straight pipe of a turbine meter and an Orifice meter, and the tests keep going with changing both diameter ratio({beta} = d/D) and flowrate(Q{sub v}). In other words, the tests were performed according to flowrate change for fixed diameter ratio. After the test was completed, the diameter ratio was increased by 0.1 and the same procedures were conducted again. The test was conducted for diameter ratio from 0.3 to 0.7. For Orifice meter, the error showed 0.4 %(Test maximum flowrate=3,030 Nm{sup 3}/h) and 0.8 %(Test maximum flowrate=9,204 Nm{sup 3}/h) for {beta}=0.3 and 0.7, respectively. For Turbine meter, the error showed -0.5 %(Test maximum flowrate=3,030 Nm{sup 3}/h) and -0.1 %(Test maximum flowrate=9,204 Nm{sup 3}/h) for {beta}=0.3 and 0.7, respectively. 44 refs., 32 figs., 27 tabs.

  3. 49 CFR 192.353 - Customer meters and regulators: Location.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Customer meters and regulators: Location. 192.353... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Customer Meters, Service Regulators, and Service Lines § 192.353 Customer meters and regulators: Location. (a) Each meter and service...

  4. Robust Meter Network for Water Distribution Pipe Burst Detection

    Directory of Open Access Journals (Sweden)

    Donghwi Jung

    2017-10-01

    Full Text Available A meter network is a set of meters installed throughout a water distribution system to measure system variables, such as the pipe flow rate and pressure. In the current hyper-connected world, meter networks are being exposed to meter failure conditions, such as malfunction of the meter’s physical system and communication system failure. Therefore, a meter network’s robustness should be secured for reliable provision of informative meter data. This paper introduces a multi-objective optimal meter placement model that maximizes the detection probability, minimizes false alarms, and maximizes the robustness of a meter network given a predefined number of meters. A meter network’s robustness is defined as its ability to consistently provide quality data in the event of meter failure. Based on a single-meter failure simulation, a robustness indicator for the meter network is introduced and maximized as the third objective of the proposed model. The proposed model was applied to the Austin network to determine the independent placement of pipe flow and pressure meters with three or five available meters. The results showed that the proposed model is a useful tool for determining meter locations to secure high detectability and robustness.

  5. Aerosol Therapy: Nebulizer vs Metered Dose Inhaler

    National Research Council Canada - National Science Library

    Newhouse, M; Dolovich, M

    1987-01-01

    ... aerosol generation using metered-dose inhalers. Previously, aerosol delivery by means of intermittent positive pressure breathing devices attached to nebulizers enjoyed unwarranted popularity for decades, only to be abandoned when convincing evidence became available that they were no better than nebulizers alone for administering bronchodilato...

  6. Pico meter metrology for the GAIA mission

    NARCIS (Netherlands)

    Meijer, E.A.; Nijenhuis, J.N.; Vink, R.J.P.; Kamphues, F.G.; Gielesen, W.L.M.; Coatantiec, C.

    2009-01-01

    To measure the relative motions of GAIA's telescopes, the angle between the telescopes is monitored by an all Silicon Carbide Basic Angle Monitoring subsystem (BAM OMA). TNO is developing this metrology system. The stability requirements for this metrology system go into the pico meter and pico

  7. An evaporation based digital microflow meter

    NARCIS (Netherlands)

    Nie, C; Frijns, A J H; Mandamparambil, R; Zevenbergen, M A G; den Toonder, J M J

    2015-01-01

    In this work, we present a digital microflow meter operating in the range 30-250 nl min-1 for water. The principle is based on determining the evaporation rate of the liquid via reading the number of wetted pore array structures in a microfluidic system, through which continuous evaporation takes

  8. Meter wavelength radio astronomy in Chile.

    Science.gov (United States)

    May, J.; Reyes, F.; Alvarez, H.; Aparici, J.; Carr, T.; Phillips, J.; Levy, J.; Lebo, G.

    Current meter-wavelength research at Maipu consists largely of a galactic survey for the southern sky, a search for secondary calibration sources, pulsar studies, a search for atmospheric pulses from Saturn, and the continuing investigation of Jovian S bursts above 30 MHz.

  9. Meter Designs Reduce Operation Costs for Industry

    Science.gov (United States)

    2013-01-01

    Marshall Space Flight Center collaborated with Quality Monitoring and Control (QMC) of Humble, Texas, through a Space Act Agreement to design a balanced flow meter for the Space Shuttle Program. QMC founded APlus-QMC LLC to commercialize the technology, which has contributed to 100 new jobs, approximately $250,000 in yearly sales, and saved customers an estimated $10 million.

  10. Educational Electrical Appliance Power Meter and Logger

    Science.gov (United States)

    Nunn, John

    2013-01-01

    The principles behind two different designs of inductive power meter are presented. They both make use of the microphone input of a computer which, together with a custom-written program, can record the instantaneous power of a domestic electrical appliance. The device can be built quickly and can be calibrated with reference to a known power…

  11. Smart wavelength meter for integrated photonics

    NARCIS (Netherlands)

    Benelajla, Meryem; Taballione, Caterina; Boller, Klaus J.

    2017-01-01

    Thermally tunable SiN waveguide microring resonators in connection with neural network readout algorithms appear promising for use as integrated optical wavelength meters. So far, we have observed long-term reliability and a temperature immunity of the readout across several degrees of ambient

  12. Assessment of the implementation regulations for smart meters; Beoordeling uitvoeringsregelingen Slimme Meter

    Energy Technology Data Exchange (ETDEWEB)

    Boekema, J.

    2011-03-15

    TNO (Netherlands) assessed whether the smart meter is reliable and future proof. By request of the Dutch Ministry of Economic Affairs, Agriculture and Innovation (ELI) an assessment was conducted of the requirements for smart meters and, as formulated in the Order in Council 'Decree on remotely readable metering devices', based on 48 tests regarding security, privacy and future stability. Taking into account a number of described recommendations, TNO deems the legislation and implementation schemes sufficient to allow for safe, reliable and future proof implementation of smart meters in the Netherlands. [Dutch] TNO heeft beoordeeld of de slimme meter betrouwbaar en toekomstvast is. Ten behoeve van het ministerie van Economische Zaken, Landbouw en Innovatie (ELI) zijn de eisen die aan slimme meters worden gesteld, en zoals verwoord in de AmvB 'Besluit op afstand uitleesbare meetinrichtingen', beoordeeld aan de hand van 48 toetsen over zekerheid (security), persoonlijke levenssfeer (privacy) en toekomstvastheid. Met inachtneming van een aantal omschreven aanbevelingen, vindt TNO wetgeving en uitvoeringsregelingen zodanig dat daarmee een veilige, betrouwbare en toekomstvaste slimme meter geimplementeerd kan worden in Nederland.

  13. KVP meter errors induced by plastic wrap

    Energy Technology Data Exchange (ETDEWEB)

    Jefferies, D.; Morris, J.W.; White, V.P. (Southern Illinois Univ., Carbondale (USA))

    1991-02-01

    The purpose of this study was to determine whether erroneous kVp meter readings, induced by plastic wrap, affected the actual kVp (output) of a dental X-ray machine. To evaluate the effect of plastic wrap on dental X-ray machine kVp meters, a radiation output device was used to measure output in mR/ma.s. An intraoral dental X-ray unit (S.S. White Model {number sign}90W) was used to make the exposures. First, the kVp meter was not covered with plastic wrap and output readings were recorded at various kVp settings with the milliamperage and time held constant. Secondly, the same kVp settings were selected before the plastic wrap was placed. Milliamperage and time were again held to the same constant. The X-ray console was then covered with plastic wrap prior to measuring the output for each kVp. The wrap possessed a static charge. This charge induced erroneous kVp meter readings. Out-put readings at the various induced kVp settings were then recorded. A kVp of 50 with no wrap present resulted in the same output as a kVp of 50 induced to read 40 or 60 kVp by the presence of wrap. Similar results were obtained at other kVp settings. This indicates that the plastic wrap influences only the kVp meter needle and not the actual kilovoltage of the X-ray machine. Dental X-ray machine operators should select kVp meter readings prior to placing plastic wrap and should not adjust initial settings if the meter is deflected later by the presence of wrap. The use of such a procedure will result in proper exposures, fewer retakes, and less patient radiation. If plastic wrap leads to consistent exposure errors, clinicians may wish to use a 0.5% sodium hypochlorite disinfectant as an alternative to the barrier technique.

  14. Household Smart Water Metering in Spain: Insights from the Experience of Remote Meter Reading in Alicante

    National Research Council Canada - National Science Library

    Hug March; alvaro-Francisco Morote; Antonio-Manuel Rico; David Saurí

    2017-01-01

    .... Beyond reducing certain labor costs, such as those related to manual meter reading, such detailed and continuous flow of information is said to enhance network efficiency and improve water planning...

  15. Metering error quantification under voltage and current waveform distortion

    Science.gov (United States)

    Wang, Tao; Wang, Jia; Xie, Zhi; Zhang, Ran

    2017-09-01

    With integration of more and more renewable energies and distortion loads into power grid, the voltage and current waveform distortion results in metering error in the smart meters. Because of the negative effects on the metering accuracy and fairness, it is an important subject to study energy metering combined error. In this paper, after the comparing between metering theoretical value and real recorded value under different meter modes for linear and nonlinear loads, a quantification method of metering mode error is proposed under waveform distortion. Based on the metering and time-division multiplier principles, a quantification method of metering accuracy error is proposed also. Analyzing the mode error and accuracy error, a comprehensive error analysis method is presented which is suitable for new energy and nonlinear loads. The proposed method has been proved by simulation.

  16. Calibration of reference KAP-meters at SSDL and cross calibration of clinical KAP-meters.

    Science.gov (United States)

    Hetland, Per O; Friberg, Eva G; Ovrebø, Kirsti M; Bjerke, Hans H

    2009-01-01

    In the summer of 2007 the secondary standard dosimetry laboratory (SSDL) in Norway established a calibration service for reference air-kerma product meter (KAP-meter). The air-kerma area product, P(KA), is a dosimetric quantity that can be directly related to the patient dose and used for risk assessment associated with different x-ray examinations. The calibration of reference KAP-meters at the SSDL gives important information on parameters influencing the calibration factor for different types of KAP-meters. The use of reference KAP-meters calibrated at the SSDL is an easy and reliable way to calibrate or verify the P(KA) indicated by the x-ray equipment out in the clinics. Twelve KAP-meters were calibrated at the SSDL by use of the substitution method at five diagnostic radiation qualities (RQRs). The calibration factors varied from 0.94 to 1.18. The energy response of the individual KAP-meters varied by a total of 20% between the different RQRs and the typical chamber transmission factors ranged from 0.78 to 0.91. It is important to use a calibrated reference KAP-meter and a harmonised calibration method in the P(KA) calibration in hospitals. The obtained uncertainty in the P(KA) readings is comparable with other calibration methods if the information in the calibration certificate is correct used, corrections are made and proper positioning of the KAP-chamber is performed. This will ensure a reliable estimate of the patient dose and a proper optimisation of conventional x-ray examinations and interventional procedures.

  17. Fuel cell membrane hydration and fluid metering

    Science.gov (United States)

    Jones, Daniel O.; Walsh, Michael M.

    1999-01-01

    A hydration system includes fuel cell fluid flow plate(s) and injection port(s). Each plate has flow channel(s) with respective inlet(s) for receiving respective portion(s) of a given stream of reactant fluid for a fuel cell. Each injection port injects a portion of liquid water directly into its respective flow channel in order to mix its respective portion of liquid water with the corresponding portion of the stream. This serves to hydrate at least corresponding part(s) of a given membrane of the corresponding fuel cell(s). The hydration system may be augmented by a metering system including flow regulator(s). Each flow regulator meters an injecting at inlet(s) of each plate of respective portions of liquid into respective portion(s) of a given stream of fluid by corresponding injection port(s).

  18. Energy Theft in the Advanced Metering Infrastructure

    Science.gov (United States)

    McLaughlin, Stephen; Podkuiko, Dmitry; McDaniel, Patrick

    Global energy generation and delivery systems are transitioning to a new computerized "smart grid". One of the principle components of the smart grid is an advanced metering infrastructure (AMI). AMI replaces the analog meters with computerized systems that report usage over digital communication interfaces, e.g., phone lines. However, with this infrastructure comes new risk. In this paper, we consider adversary means of defrauding the electrical grid by manipulating AMI systems. We document the methods adversaries will use to attempt to manipulate energy usage data, and validate the viability of these attacks by performing penetration testing on commodity devices. Through these activities, we demonstrate that not only is theft still possible in AMI systems, but that current AMI devices introduce a myriad of new vectors for achieving it.

  19. From Smart Metering to Smart Grid

    Science.gov (United States)

    Kukuča, Peter; Chrapčiak, Igor

    2016-06-01

    The paper deals with evaluation of measurements in electrical distribution systems aimed at better use of data provided by Smart Metering systems. The influence of individual components of apparent power on the power loss is calculated and results of measurements under real conditions are presented. The significance of difference between the traditional and the complex evaluation of the electricity consumption efficiency by means of different definitions of the power factor is illustrated.

  20. Fibre optic power meter calibration uncertainties

    CSIR Research Space (South Africa)

    Nel, M

    2010-06-01

    Full Text Available 2010 - EngineerIT Technical Fibre optic power meter calibration uncertainties by Mariesa Nel, NMISA and Bertus Theron, CSIR-Defence, Peace, Safety and Security This article discusses the determination of uncertainty contributions when performing a... and Instrumentation News EngineerIT - June 2010 41 Most of these uncertainty contributions can either be obtained from a calibration certificate, specifications, or empirical measurements. In the next two sections detail are given on how to determine...

  1. Industrial Medium-Btu Fuel Gas Demonstration-Plant Program. Technical support report: combustion system data. Part 2. Burner conversion survey

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-11-01

    This study was limited to an analysis of the feasibility of burning the IFG in the existing burners and combustion chambers among a group of prospective IFG customers. The results of this study indicate that the great majority of burner and equipment manufacturers recommend that the IFG can be utilized with their equipment. This is especially true with the boilers which make up the largest part of the load among the potential users of the IFG. A small number of burners representing a small part of the total potential load will probably have to be replaced. This study did not address the changes that would be required with respect to the fuel distribution piping within each facility. At a minimum of the existing regulators, flow meters, and control valves designed for the natural gas flow rates would have to be replaced to accommodate the higher fuel flow rates requiring with the IFG. In many facilities, the fuel distribution piping would have to be replaced. No changes, however, are requied for the combustion air fans or flues and stacks.

  2. Topical Metered-dosing Dispenser Performance Evaluation.

    Science.gov (United States)

    Liu, Qiang; Kupiec, Thomas C; Vu, Nicole T

    2016-01-01

    Topical metered-dosing dispensers are designed for dosing accuracy and ease-of-use by the patients while protecting the packaged products from environmental exposure and contamination. The objective of this study was to evaluate the accuracy, precision, and residual of available topical metered-dosing dispensers with different types of topical cream for practical application. Triplicate samples of five different dispensers were tested. This test was completed using three types of commercial topical cream-bases of dissimilar Total Active Pharmaceutical Ingredient Load Percentages, Transdermal Penetration Percentages, and Specific Gravities. The dispensers were evaluated according to specified dose-uniformity criteria for a total dispensing capacity of 30 mL at 0.5 mL per dose for 60 doses. The study shows Topi-CLICK performed with the best precision and accuracy of dosing in comparison to the airless-pump type dispensers. While the dispensing was highly variable with airless pumps and may require calibration for each packaged product, remarkably the performance of Topi-CLICK was not affected by different types of cream-bases and does not require additional metering calibration. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  3. Calibration and features of air-kerma length product meters.

    Science.gov (United States)

    Merimaa, K; Tapiovaara, M; Kosunen, A; Toroi, P

    2012-12-01

    Pencil-type air-kerma length product meters are generally used for quality control and radiation exposure measurements in computed tomography. To ensure reliable results, these meters should be calibrated so that measurements are traceable to international standards. Suitable calibration procedures, together with the properties of these meters, were examined and compared with the international standards and recommendations. The calibration procedure and setup used in this study were slightly modified compared with international recommendations. The special collimator system was found to cause less scatter than similar setups in earlier studies. The energy dependence of the meter response was investigated for several types of meters with standard radiation qualities. With most tested meter types, the total variation due to energy dependence was meter type varied up to 8 % when rotating the meter around its axis; this should be taken into account when making calibrations with a static setup.

  4. Investigating water meter performance in developing countries: A ...

    African Journals Online (AJOL)

    2011-10-07

    Oct 7, 2011 ... refers to the ISO classification for water meters and indicates the ability of the meter to measure low flows. Class D meters have the greatest ability to measure low flows and Class A have the least ability. Pressure measurements were also carried out at the properties (using Hydreka Vistaplus pressure data ...

  5. 49 CFR 192.359 - Customer meter installations: Operating pressure.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Customer meter installations: Operating pressure... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Customer Meters, Service Regulators, and Service Lines § 192.359 Customer meter installations: Operating pressure...

  6. 49 CFR 192.357 - Customer meters and regulators: Installation.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Customer meters and regulators: Installation. 192... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Customer Meters, Service Regulators, and Service Lines § 192.357 Customer meters and regulators: Installation. (a...

  7. The disc pasture meter: Possible applications in grazing management.

    African Journals Online (AJOL)

    The disc meter is a simple inexpensive instrument which may be used to make rapid yield estimates of standing forage. Linear regression relationships between meter reading and pasture dry matter yield are usually fairly good, but these may be affected by a number of different factors. The meter should therefore be ...

  8. Geometrical correction factors for heat flux meters

    Science.gov (United States)

    Baumeister, K. J.; Papell, S. S.

    1974-01-01

    General formulas are derived for determining gage averaging errors of strip-type heat flux meters used in the measurement of one-dimensional heat flux distributions. The local averaging error e(x) is defined as the difference between the measured value of the heat flux and the local value which occurs at the center of the gage. In terms of e(x), a correction procedure is presented which allows a better estimate for the true value of the local heat flux. For many practical problems, it is possible to use relatively large gages to obtain acceptable heat flux measurements.

  9. Enclosure design for Thirty Meter Telescope

    Science.gov (United States)

    Loewen, N.; Breckenridge, C.; Vasiljevic, A.

    2008-07-01

    The design of the calotte enclosure for the Thirty-Meter Telescope is currently in the preliminary design phase. Key aspects of the design include an efficient structural/mechanical form, repetition of components, modular construction, and operational efficiency. This paper includes an overall description of the enclosure design, as well as a description of the major structural and mechanical subsystems. The enclosure incorporates features that influence the thermal and aerodynamic environment of the telescope including ventilation openings and wind deflecting features. Other key considerations of the preliminary design include the constructability and maintainability of a dynamic structure of this scale at a remote mountain site.

  10. PRESCILA: a new, lightweight neutron rem meter.

    Science.gov (United States)

    Olsher, Richard H; Seagraves, David T; Eisele, Shawna L; Bjork, Christopher W; Martinez, William A; Romero, Leonard L; Mallett, Michael W; Duran, Michael A; Hurlbut, Charles R

    2004-06-01

    Conventional neutron rem meters currently in use are based on 1960's technology that relies on a large neutron moderator assembly surrounding a thermal detector to achieve a rem-like response function over a limited energy range. Such rem meters present an ergonomic challenge, being heavy and bulky, and have caused injuries during radiation protection surveys. Another defect of traditional rem meters is a poor high-energy response above 10 MeV, which makes them unsuitable for applications at high-energy accelerator facilities. Proton Recoil Scintillator-Los Alamos (PRESCILA) was developed as a low-weight (2 kg) alternative capable of extended energy response, high sensitivity, and moderate gamma rejection. An array of ZnS(Ag) based scintillators is located inside and around a Lucite light guide, which couples the scintillation light to a sideview bialkali photomultiplier tube. The use of both fast and thermal scintillators allows the energy response function to be optimized for a wide range of operational spectra. The light guide and the borated polyethylene frame provide moderation for the thermal scintillator element. The scintillators represent greatly improved versions of the Hornyak and Stedman designs from the 1950's, and were developed in collaboration with Eljen Technology. The inherent pulse height advantage of proton recoils over electron tracks in the phosphor grains eliminates the need for pulse shape discrimination and makes it possible to use the PRESCILA probe with standard pulse height discrimination provided by off-the-shelf health physics counters. PRESCILA prototype probes have been extensively tested at both Los Alamos and the German Bureau of Standards, Physikalisch-Technische Bundesanstalt. Test results are presented for energy response, directional dependence, linearity, sensitivity, and gamma rejection. Initial field tests have been conducted at Los Alamos and these results are also given. It is concluded that PRESCILA offers a viable

  11. Smart Metering. Synergies within medium voltage automation; Synergien durch Smart Metering. Automatisierung auf Mittelspannungsebene

    Energy Technology Data Exchange (ETDEWEB)

    Maas, Peter [IDS GmbH, Ettlingen (Germany)

    2010-11-15

    Transparent interdivisional system solutions are an indispensable and decisive precondition for the optimization of business processes. The implementation of a Smart Metering solution does not only provide data for billing purposes, but also renders important data for network operation. Synergies can be achieved through the use of a common infrastructure which covers both the needs of Smart Metering and network operation. An open architecture of the solution allows for the future integration of further services of the domains Smart Grid and Smart Home. (orig.)

  12. Synergisms between smart metering and smart grid; Synergien zwischen Smart Metering und Smart Grid

    Energy Technology Data Exchange (ETDEWEB)

    Maas, Peter [IDS GmbH, Ettlingen (Germany)

    2010-04-15

    With the implementation of a smart metering solution, it is not only possible to acquire consumption data for billing but also to acquire relevant data of the distribution grid for grid operation. There is still a wide gap between the actual condition and the target condition. Synergies result from the use of a common infrastructure which takes account both of the requirements of smart metering and of grid operation. An open architecture also enables the future integration of further applications of the fields of smart grid and smart home. (orig.)

  13. Long Island Smart Metering Pilot Project

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2012-03-30

    The Long Island Power Authority (LIPA) Smart Meter Pilots provided invaluable information and experience for future deployments of Advanced Metering Infrastructure (AMI), including the deployment planned as part of LIPA's Smart Grid Demonstration Project (DE-OE0000220). LIPA will incorporate lessons learned from this pilot in future deployments, including lessons relating to equipment performance specifications and testing, as well as equipment deployment and tracking issues. LIPA ultimately deployed three AMI technologies instead of the two that were originally contemplated. This enabled LIPA to evaluate multiple systems in field conditions with a relatively small number of meter installations. LIPA experienced a number of equipment and software issues that it did not anticipate, including issues relating to equipment integration, ability to upgrade firmware and software over the air (as opposed to physically interacting with every meter), and logistical challenges associated with tracking inventory and upgrade status of deployed meters. In addition to evaluating the technology, LIPA also piloted new Time-of-Use (TOU) rates to assess customer acceptance of time-differentiated pricing and to evaluate whether customers would respond by adjusting their activities from peak to non-peak periods. LIPA developed a marketing program to educate customers who received AMI in the pilot areas and to seek voluntary participation in TOU pricing. LIPA also guaranteed participating customers that, for their initial year on the rates, their electricity costs under the TOU rate would not exceed the amount they would have paid under the flat rates they would otherwise enjoy. 62 residential customers chose to participate in the TOU rates, and every one of them saved money during the first year. 61 of them also elected to stay on the TOU rate without the cost guarantee at the end of that year. The customer who chose not to continue on the rate was also the one who achieved the

  14. A hybrid ICT-solution for smart meter data analytics

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Nielsen, Per Sieverts

    2016-01-01

    conditions and user information, which makes the data sets very sizable and the analytics complex. Data mining and emerging cloud computing technologies make collecting, processing, and analyzing the so-called big data possible. This paper proposes an innovative ICT-solution to streamline smart meter data...... analytics. The proposed solution offers an information integration pipeline for ingesting data from smart meters, a scalable platform for processing and mining big data sets, and a web portal for visualizing analytics results. The implemented system has a hybrid architecture of using Spark or Hive for big......Smart meters are increasingly used worldwide. Smart meters are the advanced meters capable of measuring energy consumption at a fine-grained time interval, e.g., every 15 min. Smart meter data are typically bundled with social economic data in analytics, such as meter geographic locations, weather...

  15. A hybrid ICT-solution for smart meter data analytics

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Nielsen, Per Sieverts

    2016-01-01

    Smart meters are increasingly used worldwide. Smart meters are the advanced meters capable of measuring energy consumption at a fine-grained time interval, e.g., every 15 min. Smart meter data are typically bundled with social economic data in analytics, such as meter geographic locations, weather...... conditions and user information, which makes the data sets very sizable and the analytics complex. Data mining and emerging cloud computing technologies make collecting, processing, and analyzing the so-called big data possible. This paper proposes an innovative ICT-solution to streamline smart meter data...... analytics. The proposed solution offers an information integration pipeline for ingesting data from smart meters, a scalable platform for processing and mining big data sets, and a web portal for visualizing analytics results. The implemented system has a hybrid architecture of using Spark or Hive for big...

  16. A Probabilistic Model of Meter Perception: Simulating Enculturation

    Directory of Open Access Journals (Sweden)

    Bastiaan van der Weij

    2017-05-01

    Full Text Available Enculturation is known to shape the perception of meter in music but this is not explicitly accounted for by current cognitive models of meter perception. We hypothesize that the induction of meter is a result of predictive coding: interpreting onsets in a rhythm relative to a periodic meter facilitates prediction of future onsets. Such prediction, we hypothesize, is based on previous exposure to rhythms. As such, predictive coding provides a possible explanation for the way meter perception is shaped by the cultural environment. Based on this hypothesis, we present a probabilistic model of meter perception that uses statistical properties of the relation between rhythm and meter to infer meter from quantized rhythms. We show that our model can successfully predict annotated time signatures from quantized rhythmic patterns derived from folk melodies. Furthermore, we show that by inferring meter, our model improves prediction of the onsets of future events compared to a similar probabilistic model that does not infer meter. Finally, as a proof of concept, we demonstrate how our model can be used in a simulation of enculturation. From the results of this simulation, we derive a class of rhythms that are likely to be interpreted differently by enculturated listeners with different histories of exposure to rhythms.

  17. Aperture meter for the Large Hadron Collider

    CERN Document Server

    Müller, G J; Redaelli, S

    2011-01-01

    The control of the high intensity beams of the CERN Large Hadron Collider (LHC) is particular challenging and requires a good modeling of the machine and monitoring of various machine parameters. During operation it is crucial to ensure a minimal distance between the beam edge and the aperture of sensitive equipment, e.g. the superconductingmagnets, which in all cases must be in the shadowof the collimator’s that protect the machine. Possible dangerous situations must be detected as soon as possible. In order to provide the operator with information about the current machine bottlenecks an aperture meter application was developed based on the LHC online modeling toolchain. The calculation of available free aperture takes into account the best available optics and aperture model as well as the relevant beam measurements. This paper describes the design and integration of this application into the control environment and presents results of the usage in daily operation and from validation measurements.

  18. Commissioning subsystems of the 10 meter prototype

    Science.gov (United States)

    Prins, Nathan; Fricke, Tobin; Mow-Lowry, Conor; Hanke, Manuela

    2015-04-01

    The best attempts at detecting the elusive gravitational waves are with L-shaped interferometers. Over the summer of 2014, I helped install subsystems of the 10 meter prototype, a gravitational wave interferometer designed to reach the Standard Quantum Limit (SQL), at the Max Planck Institute for Gravitational Physics in Hannover, Germany through the University of Florida's International REU. While there, the frequency reference cavity was aligned and the mode matching the cavity began. We also worked on installing and testing the intensity stabilization servo, which consisted of an out-of-vacuum photodiode for each the in-loop and out-of-loop sensing that were being connected to the LIGO Control and Data System.

  19. Five meter diameter conical furlable antenna

    Science.gov (United States)

    Fortenberry, J. W.; Freeland, R. E.; Moore, D. M.

    1976-01-01

    An investigation was made to demonstrate that a 5-meter-diameter, furlable, conical reflector antenna utilizing a line source feed can be fabricated utilizing composite materials and to prove that the antenna can function mechanically and electrically as prototype flight hardware. The design, analysis, and testing of the antenna are described. An RF efficiency of 55% at 8.5 GHz and a surface error of 0.64 mm rms were chosen as basic design requirements. Actual test measurements yielded an efficiency of 53% (49.77 dB gain) and a surface error of 0.61 mm rms. Atmospherically induced corrosion of the reflector mesh resulted in the RF performance degradation. An assessment of the antenna as compared to the current state of the art technology was made. This assessment included cost, surface accuracy and RF performance, structural and mechanical characteristics, and possible applications.

  20. The Ozone Layer and Metered Dose Inhalers

    Directory of Open Access Journals (Sweden)

    Louis-Philippe Boulet

    1998-01-01

    Full Text Available The stratospheric ozone layer plays a crucial role in protecting living organisms against ultraviolet radiation. Chlorofluorocarbons (CFC contained in metered-dose inhalers (MDIs contribute to ozone depletion and in accordance with the Montreal Protocol on Substances That Deplete the Ozone Layer established 10 years ago, phase-out strageies have been developed worldwide for this category of agents. Alternatives to CFC-containing inhalers have been developed, such as powder inhalers and those using hydrofluoroalkanes (HFAs as propellants, which have been shown to be as safe and effective as CFC-containing inhalers and even offer interesting advantages over older inhalers. The transition to non-CFC MDIs requires a major effort to make the new products available and to ensure adequate comparision with the previous ones. It also requires a harmonization of actions taken by industry, government, licencing bodies and patients or health professional associations to ensure adequate information and education to the public and respiratory care providers.

  1. Handheld Multi-Gas Meters Assessment Report

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Gustavious [Brigham Young Univ., Provo, UT (United States); Wald-Hopkins, Mark David [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Obrey, Stephen J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Akhadov, Valida Dushdurova [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-27

    Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the monitored chemical. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. In April 2016 the System Assessment and Validation for Emergency Responders (SAVER) Program conducted an operationally-oriented assessment of MGMs. Five MGMs were assessed by emergency responders. The criteria and scenarios used in this assessment were derived from the results of a focus group of emergency responders with experience in using MGMs. The assessment addressed 16 evaluation criteria in four SAVER categories: Usability, Capability, Maintainability, and Deployability.

  2. Radiation survey meters used for environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bjerke, H. (ed.) (Norwegian Radiation Protection Authority, NRPA (Norway)); Sigurdsson, T. (Icelandic Radiation Safety Authority, Geislavarnir Rikisins, GR (IS)); Meier Pedersen, K. (National Board of Health, Statens Institut for Straalebeskyttelse (SIS) (Denmark)); Grindborg, J.-E.; Persson, L. (Swedish Radiation Safety Authority, Straalsaekerhetsmyndigheten (SSM) (Sweden)); Siiskonen, T.; Hakanen, A.; Kosunen, A. (Radiation and Nuclear Safety Authority, Saeteilyturvakeskus (STUK) (Finland))

    2012-01-15

    The Nordic dosimetry group set up the GammaRate project to investigate how its expertise could be used to assure appropriate usage of survey meters in environmental monitoring. Considerable expertise in calibrating radiation instruments exists in the Nordic radiation protection authorities. The Swedish, Finnish, Danish and Norwegian authorities operate Secondary Standard Dosimetry Laboratories (SSDLs) that provide users with calibration traceable to internationally recognised primary standards. These authorities together with the Icelandic authorities have formally cooperated since 2002 in the field of radiation dosimetry. Dosimetry is the base for assesment of risk from ionising radiation and calibration of instruments is an imported part in dosimetry. The Nordic dosimetry group has been focused on cancer therapy. This work extends the cooperation to the dosimetry of radiation protection and environmental monitoring. This report contains the formal, theoretical and practical background for survey meter measurements. Nordic standards dosimetry laboratories have the capability to provide traceable calibration of instruments in various types of radiation. To verify and explore this further in radiation protection applications a set of survey instruments were sent between the five Nordic countries and each of the authority asked to provide a calibration coefficient for all instruments. The measurement results were within the stated uncertainties, except for some results from NRPA for the ionchamber based instrument. The comparison was shown to be a valuable tool to harmonize the calibration of radiation protection instruments in the Nordic countries. Dosimetry plays an important role in the emergency situations, and it is clear that better traceability and harmonised common guidelines will improve the emergency preparedness and health. (Author)

  3. Method and apparatus for reading meters from a video image

    Science.gov (United States)

    Lewis, Trevor J.; Ferguson, Jeffrey J.

    1997-01-01

    A method and system to enable acquisition of data about an environment from one or more meters using video images. One or more meters are imaged by a video camera and the video signal is digitized. Then, each region of the digital image which corresponds to the indicator of the meter is calibrated and the video signal is analyzed to determine the value indicated by each meter indicator. Finally, from the value indicated by each meter indicator in the calibrated region, a meter reading is generated. The method and system offer the advantages of automatic data collection in a relatively non-intrusive manner without making any complicated or expensive electronic connections, and without requiring intensive manpower.

  4. Deducing Energy Consumer Behavior from Smart Meter Data

    DEFF Research Database (Denmark)

    Ebeid, Emad Samuel Malki; Heick, Rune; Jacobsen, Rune Hylsberg

    2017-01-01

    The ongoing upgrade of electricity meters to smart ones has opened a new market of intelligent services to analyze the recorded meter data. This paper introduces an open architecture and a unified framework for deducing user behavior from its smart main electricity meter data and presenting the r...... the recognized home appliances. The framework uses open standard interfaces for exchanging data. The framework has been validated through comprehensive experiments that are related to an European Smart Grid project.......The ongoing upgrade of electricity meters to smart ones has opened a new market of intelligent services to analyze the recorded meter data. This paper introduces an open architecture and a unified framework for deducing user behavior from its smart main electricity meter data and presenting...

  5. Smart Meter Data Analytics: Systems, Algorithms and Benchmarking

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Golab, Lukasz; Golab, Wojciech

    2016-01-01

    Smart electricity meters have been replacing conventional meters worldwide, enabling automated collection of fine-grained (e.g., every 15 minutes or hourly) consumption data. A variety of smart meter analytics algorithms and applications have been proposed, mainly in the smart grid literature....... However, the focus has been on what can be done with the data rather than how to do it efficiently. In this paper, we examine smart meter analytics from a software performance perspective. First, we design a performance benchmark that includes common smart meter analytics tasks. These include off......-line feature extraction and model building as well a framework for on-line anomaly detection that we propose. Second, since obtaining real smart meter data is difficult due to privacy issues, we present an algorithm for generating large realistic data sets from a small seed of real data. Third, we implement...

  6. Advanced Metering Installations – A Perspective from Federal Sites

    Energy Technology Data Exchange (ETDEWEB)

    Earni, Shankar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Technologies Area

    2016-05-02

    This report is intended to provide guidance to the United States Department of Energy (DOE) and other federal agencies to highlight some of the existing practices related to advanced building metering systems. This study identified some of the existing actions related to advanced meter data and proposes how advanced metered data can be employed to develop robust cost effective measurement and verification (M&V) strategies. This report proposes an integrated framework on how advanced meter data can be used to identify energy conservation opportunities and to develop proactive M&V strategies to ensure that the savings for energy projects are being realized. This information will help improve metering, feedback, and dashboard implementations for reducing energy use at DOE facilities, based on lessons learned from various advanced metering implementations.

  7. De Minimis Thresholds for Federal Building Metering Appropriateness

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, Jordan W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-03-31

    The U.S. Department of Energy (DOE) is required by statute and Presidential Memorandum to establish guidelines for agencies to meter their Federal buildings for energy (electricity, natural gas, and steam) and water. See 42 U.S.C. § 8253(e). DOE issued guidance in February 2006 on the installation of electric meters in Federal buildings. A recent update to the 2006 guidance accounts for more current metering practices within the Federal Government. The updated metering guidance specifies that all Federal buildings shall be considered “appropriate” for energy or water metering unless identified for potential exclusion. In developing the updated guidance to carry out the statue, Congress also directed DOE to (among other things) establish exclusions from the metering requirements based on the de minimis quantity of energy use of a Federal building, industrial process, or structure. This paper discusses the method used to identify de minimis values.

  8. Enhancing Observability in Distribution Grids using Smart Meter Data

    OpenAIRE

    Bhela, Siddharth; Kekatos, Vassilis; Veeramachaneni, Sriharsha

    2016-01-01

    Due to limited metering infrastructure, distribution grids are currently challenged by observability issues. On the other hand, smart meter data, including local voltage magnitudes and power injections, are communicated to the utility operator from grid buses with renewable generation and demand-response programs. This work employs grid data from metered buses towards inferring the underlying grid state. To this end, a coupled formulation of the power flow problem (CPF) is put forth. Exploiti...

  9. Development of a hand-held fast neutron survey meter.

    Science.gov (United States)

    Yoshida, T; Tsujimura, N; Yamano, T

    2011-07-01

    A neutron survey meter with a ZnS(Ag) scintillator to measure recoil protons was built. The detection probe weighs ~2 kg, therefore providing us with true portability. Performance tests exhibited satisfactory neutron dosimetry characteristics in unmoderated or lightly moderated fission neutron fields and in particular work environments at a mixed oxide fuel facility. This new survey meter will augment a routine of neutron monitoring that is inconveniently being carried out by moderator-based neutron survey meters.

  10. FUSION OF VENTURI AND ULTRASONIC FLOW METER FOR ENHANCED FLOW METER CHARACTERISTICS USING FUZZY LOGIC

    Directory of Open Access Journals (Sweden)

    K.V. Santhosh

    2015-04-01

    Full Text Available This paper proposes a technique for measurement of liquid flow using venturi and ultrasonic flow meter(UFM to have following objectives a to design a multi-sensor data fusion (MSDF architecture for using both the sensors, b improve sensitivity and linearity of venturi and ultrasonic flow meter, and c detect and diagnosis of faults in sensor if any. Fuzzy logic algorithm is used to fuse outputs of both the sensor and train the fuzzy block to produces output which has an improved characteristics in terms of both sensitivity and linearity. For identification of sensor faults a comparative test algorithm is designed. Once trained proposed technique is tested in real life, results show successful implementation of proposed objectives.

  11. Investigation and Comparison of Separate Meter-In Separate Meter-Out Control Strategies

    DEFF Research Database (Denmark)

    Pedersen, Henrik C.; Andersen, Torben Ole; Skoubo, Tobias

    2014-01-01

    . The possibility to independently control the meter-in and meter-out side not only increase the functionality of the system, but also opens up for better performance and/or lowered energy consumption. The focus of the current paper is therefore on investigation and comparison of what may be obtained using...... multivariable control strategies for SMISMO control of a single axis hydraulic system with a differential cylinder, when not taking other measures to improve performance. The paper first presents an experimentally verified model of the system considered, from which a linear model is derived. Based on the model......, the control strategies are discussed and severalH¥ controllers are designed, for which both simulation and experimental results are presented. The controllers are evaluated with regard to performance and robustness and compared to a simple SISO control. Based on the findings, the possibilities and limitations...

  12. Collaborative Outbound Taxi Metering for Environmental Benefits Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal addresses the concept of Collaborative Outbound Taxi Metering (COTM), which provides environmental benefits without sacrificing throughput. In current...

  13. A Scalable Smart Meter Data Generator Using Spark

    DEFF Research Database (Denmark)

    Iftikhar, Nadeem; Liu, Xiufeng; Danalachi, Sergiu

    2017-01-01

    Today, smart meters are being used worldwide. As a matter of fact smart meters produce large volumes of data. Thus, it is important for smart meter data management and analytics systems to process petabytes of data. Benchmarking and testing of these systems require scalable data, however, it can...... be challenging to get large data sets due to privacy and/or data protection regulations. This paper presents a scalable smart meter data generator using Spark that can generate realistic data sets. The proposed data generator is based on a supervised machine learning method that can generate data of any size...

  14. A Novel Smart Meter Controlling System with Dynamic IP Addresses

    DEFF Research Database (Denmark)

    Manembu, Pinrolinvic; Welang, Brammy; Kalua Lapu, Aditya

    2017-01-01

    Smart meters are the electronic devices for measuring energy consumption in real time. Usually, static public IP addresses are allocated to realize the point-to-point (P2P) communication and remote controlling for smart metering systems. This, however, restricts the wide deployment of smart meters......, due to the deficiency of public IP resources. This paper proposes a novel subscription-based communication architecture for the support of dynamic IP addresses and group controlling of smart meters. The paper evaluates the proposed architecture by comparing the traditional P2P architecture...

  15. On Calibration of pH Meters

    Directory of Open Access Journals (Sweden)

    Da-Ming Zhu

    2005-04-01

    Full Text Available The calibration of pH meters including the pH glass electrode, ISE electrodes,buffers, and the general background for calibration are reviewed. Understanding of basicconcepts of pH, pOH, and electrode mechanism is emphasized. New concepts of pH, pOH,as well as critical examination of activity, and activity coefficients are given. Theemergence of new solid state pH electrodes and replacement of the salt bridge with aconducting wire have opened up a new horizon for pH measurements. A pH buffer solutionwith a conducting wire may be used as a stable reference electrode. The misleadingunlimited linear Nernstian slope should be discarded. Calibration curves with 3 nonlinearportions for the entire 0—14 pH range due to the isoelectric point change effect areexplained. The potential measurement with stirring or unstirring and effects by double layer(DL and triple layer (TL will be discussed.

  16. Recent patents in pressurised metered dose inhalers.

    Science.gov (United States)

    Ehtezazi, Touraj

    2012-04-01

    In this paper recent patents in pressurised metered dose inhalers have been reviewed. The patents are related to novel valves, dose-counters, formulations, add-on devices, reduction of propellant leakage and inkjet technology. Recently patented dose-counters provide mechanisms that are less susceptible to inaccuracy, and are battery-less electronic dose-counters with the help of miniature electromechanical generators. Regarding the formulation aspect, recent patents provide methods for combinational pMDIs and more stable products. Advantages of recently patented valves are being spring-free and less subject to loss of prime. Recent developments in micromachining have allowed patents that incorporate inkjet technology to develop inhalers that are similar to pMDIs, but produce uniform aerosol droplets. Coating canisters with suitable polymers has reduced need for excipients. Recently patented add-on devices reduce aerosol deposition in the spacer by creating turbulence on the walls of the chamber. Blockage of nozzles in actuators is prevented by providing tapered nozzle channels. In conclusion, these patents show better understanding of pMDIs and provide methods to achieve products with much improved reliability, aerosol performance and stability.

  17. Meter data everywhere: online energy information services

    Energy Technology Data Exchange (ETDEWEB)

    Fesmire, R.

    2002-07-01

    The value and importance of web-based energy information services are discussed, emphasizing the advantages of such services to end users and considering ways to encourage end users to make effective use of these advanced metering systems. Results of a survey to investigate key factors in customer acceptance of energy information services show that most energy customers rank guaranteed savings, ease of use and user friendliness as the most important considerations in choosing an energy information service vendor. Among the components end users gave highest rating to the ability provided by energy information services to understand their energy usage, and it is widely agreed that whatever other services EIS may provide, usage analysis is the one that end users are willing to pay a reasonable fee to receive. The pros and cons of in-house-built EIS versus outsourcing was also considered, with the advantage going to outsourcing on account of the shorter implementation time, access to the latest technology, the prospects of freeing up internal resources, and guaranteed system uptime, performance, security and reliability. 3 figs.

  18. Measuring methods in power metering 2013; Elektrizitaetsmesstechnik 2013

    Energy Technology Data Exchange (ETDEWEB)

    Kahmann, Martin; Zayer, Peter (eds.)

    2012-07-01

    The book addresses technical and economic issues of power metering, data communication and data processing. Smart metering is the key issue discussed in all 14 contributions: 1. The perspective of Smart Metering in Europe through 2020; 2. Introduction of Smart Metering in Austria; 3. Metering after the amended EnWG 2011; 4. The FNN project ''MessSystem 2020''; 5. Technological requirements of Smart Grid and Smart Market; 6. DIN Spec 33440 ''Ergonomic Aspects of Smart Grids and Electromobility''; 7. Load management as a key element of energy transition; 8. Added value in Smart Metering as a result of Smart Home applications, 9. The main cost factors of the new metering systems; 10. BSI protection profile: Smart Meter Gateway certification; 11. The influence of new boundary conditions in metering on intercompany processes; 12. Reliable time allotment via internet; 13. Recommendations of the EEG Clearing Authority on metering problems; 14. Outline quality management manual for state-authorized test services for electric power, gas, water, and heat. [German] Dieses Buch richtet seinen Blick sowohl auf technische wie auch auf energiewirtschaftliche Themen rund um das Thema Mess- und Zaehltechnik sowie die inzwischen immer bedeutsamer werdende zugehoerige Datenkommunikations- und Datenverarbeitungstechnik. Eine zunehmende Betrachtung des Smart Metering als einen Teilaspekt des grossen Themas Smart Grid bildet die gemeinsame Klammer um die Beitraege. Die Themen der 14 Beitraege sind: 1. Perspektive Smart Metering in Europa bis 2020; 2. Smart-Meter-Einfuehrung in Oesterreich; 3. Das Messwesen nach der EnWG-Novelle 2011; 4. Das FNN-Projekt ''MessSystem 2020''; 5. Anforderungen durch Smart Grid und Smart Market an die intelligente Messtechnik; 6. DIN Spec 33440 ''Ergonomie-Aspekte zu Smart Grid und Elektromobilitaet''; 7. Lastverschiebung als Baustein der Energiewende; 8. Mehrwerte beim Smart

  19. Development of a novel vortex flow meter for downhole use

    NARCIS (Netherlands)

    Schiferli, W.; Cheng, L.K.

    2008-01-01

    Due to the increasing complexity of oil and gas wells, the demand for instrumentation to measure conditions inside well tubing below the surface is growing rapidly. A robust meter was designed to measure liquid flows at downhole conditions. The meter is based on a specially-designed bluff body to

  20. Investigating water meter performance in developing countries: A ...

    African Journals Online (AJOL)

    2011-10-07

    Oct 7, 2011 ... High levels of water losses in distribution systems are the main challenge that water utilities in developing countries cur- rently face. ... industry, especially in developing countries, to make appropriate metering and sub-metering decisions. ... the case study, followed by the research methodology used in.

  1. Real time Aanderaa current meter data collection system

    Digital Repository Service at National Institute of Oceanography (India)

    AshokKumar, K.; Diwan, S.G.

    in laboratory. In this paper a method is described to read the real time current meter data and display/print/store on cartridge. For this, binary coded electrical signal available at the top end plate of the current meter is connectEd. by underwater cable...

  2. Inaccuracy of portable peak flow meters : correction is not needed

    NARCIS (Netherlands)

    Brand, PLP; Waalkens, HJ; Duiverman, EJ; vanEssenZandvliet, EEM

    This study examined whether correction of peak expiratory flow (PEF) values for the inaccuracy of the meter would affect asthma management in 102 children (7-14 y old). PEF was recorded with a mini Wright meter twice daily for 2 weeks. As expected, measured PEF overestimated PEF level and asthma

  3. The accuracy of self monitoring blood glucose meter systems in ...

    African Journals Online (AJOL)

    However, those on meter system B and C were significantly lower and different. Temperature and humidity adversely affected the analytical performance of meter systems B and C in the Kampala environ. Conclusion: Some of the blood glucose monitoring systems in Kampala, Uganda are poor performers and may lead to ...

  4. Investigating water meter performance in developing countries: A ...

    African Journals Online (AJOL)

    High levels of water losses in distribution systems are the main challenge that water utilities in developing countries currently face. The water meter is an essential tool for both the utility and the customers to measure and monitor consumption. When metering is inefficient and coupled with low tariffs, the financial ...

  5. Optimal water meter selection system | Johnson | Water SA

    African Journals Online (AJOL)

    The relative frequency of the volume of water passing through a meter at various flow rates and the weighted accuracies of these measured volumes play a pivotal role in establishing a common comparison reference. The time unit selected to calculate the volume of water passing through the meter is guided by the type of ...

  6. 24 CFR 965.401 - Individually metered utilities.

    Science.gov (United States)

    2010-04-01

    ... Existing PHA-Owned Projects § 965.401 Individually metered utilities. (a) All utility service shall be individually metered to residents, either through provision of retail service to the residents by the utility... or public service commission. (b) If checkmetering is not permissible, retail service shall be...

  7. Microwave moisture meter for in-shell peanut kernels

    Science.gov (United States)

    . A microwave moisture meter built with off-the-shelf components was developed, calibrated and tested in the laboratory and in the field for nondestructive and instantaneous in-shell peanut kernel moisture content determination from dielectric measurements on unshelled peanut pod samples. The meter ...

  8. Designing remote web-based mechanical-volumetric flow meter ...

    African Journals Online (AJOL)

    Today, in water and wastewater industry a lot of mechanical-volumetric flow meters are used for the navigation of the produced water and the data of these flow meters, due to use in a wide geographical range, is done physically and by in person presence. All this makes reading the data costly and, in some cases, due to ...

  9. 18 CFR 367.9020 - Account 902, Meter reading expenses.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Account 902, Meter reading expenses. 367.9020 Section 367.9020 Conservation of Power and Water Resources FEDERAL ENERGY... GAS ACT Operation and Maintenance Expense Chart of Accounts § 367.9020 Account 902, Meter reading...

  10. Justification of the Utility of Introducing Smart Meters in Latvia

    Directory of Open Access Journals (Sweden)

    Kunickis M.

    2015-12-01

    Full Text Available Automatic data reading from smart meters is being developed in many parts of the world, including Latvia. The key drivers for that are developments of smart technologies and economic benefits for consumers. Deployment of smart meters could be launched in a massive scale.

  11. Development and Testing of Infrared Water Current Meter | Ezenne ...

    African Journals Online (AJOL)

    Continuous monitoring of the river flow is essential for assessing water availability. River flow velocity is crucial to simulate discharge hydrographs of water in the hydrological system.This study developed a digital water current meter with infrared. The infrared current meter was tested using Ebonyi River at Obollo-Etiti and ...

  12. A prepaid meter using mobile communication | Jain | International ...

    African Journals Online (AJOL)

    This paper suggests a prepaid energy meter behaving like a prepaid mobile phone. The meter contains a prepaid card analogous to mobile SIM card. The prepaid card communicates with the power utility using mobile communication infrastructure. Once the prepaid card is out of balance, the consumer load is disconnected ...

  13. Design of a Robust Prepaid Energy Metering and Billing System ...

    African Journals Online (AJOL)

    ... detector(GBTD) which detects abnormalities and sends sms alert to power utility for on site visit or investigation. A prior billing is bound to do away with the problems of unpaid bills and human error in meter readings, thereby ensuring justified revenue for the utility. Keywords: SMS, GSM, microcontroller, energy meter, ...

  14. The Thirty Meter Telescope (TMT): An International Observatory

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... The Thirty Meter Telescope (TMT) will be the first truly global ground-based optical/infrared observatory. It will initiate the era of extremely large (30-meter class) telescopes with diffraction limited performance from its vantage point in the northern hemisphere on Mauna Kea, Hawaii, USA. The astronomy ...

  15. Justification of the Utility of Introducing Smart Meters in Latvia

    Science.gov (United States)

    Kunickis, M.; Dandens, A.; Bariss, U.

    2015-12-01

    Automatic data reading from smart meters is being developed in many parts of the world, including Latvia. The key drivers for that are developments of smart technologies and economic benefits for consumers. Deployment of smart meters could be launched in a massive scale. Several pilot projects were implemented to verify the feasibility of smart meters for individual consumer groups. Preliminary calculations indicate that installation of smart meters for approximately 23 % of electricity consumers would be economically viable. Currently, the data for the last two years is available for an in-depth mathematical analysis. The continuous analysis of consumption data would be established, when more measurements from smart meters are available. The extent of introduction of smart meters should be specified during this process in order to gain the maximum benefit for the whole society (consumers, grid companies, state authorities), because there are still many uncertain and variable factors. For example, it is necessary to consider statistical load variations by hour, dependence of electricity consumption on temperature fluctuations, consumer behaviour and demand response to market signals to reduce electricity consumption in the short and long term, consumer's ambitions and capability to install home automation for regulation of electricity consumption. To develop the demand response, it is necessary to analyse the whole array of additional factors, such as expected cost reduction of smart meters, possible extension of their functionality, further development of information exchange systems, as well as standard requirements and different political and regulatory decisions regarding the reduction of electricity consumption and energy efficiency.

  16. Weather Impact on Airport Arrival Meter Fix Throughput

    Science.gov (United States)

    Wang, Yao

    2017-01-01

    Time-based flow management provides arrival aircraft schedules based on arrival airport conditions, airport capacity, required spacing, and weather conditions. In order to meet a scheduled time at which arrival aircraft can cross an airport arrival meter fix prior to entering the airport terminal airspace, air traffic controllers make regulations on air traffic. Severe weather may create an airport arrival bottleneck if one or more of airport arrival meter fixes are partially or completely blocked by the weather and the arrival demand has not been reduced accordingly. Under these conditions, aircraft are frequently being put in holding patterns until they can be rerouted. A model that predicts the weather impacted meter fix throughput may help air traffic controllers direct arrival flows into the airport more efficiently, minimizing arrival meter fix congestion. This paper presents an analysis of air traffic flows across arrival meter fixes at the Newark Liberty International Airport (EWR). Several scenarios of weather impacted EWR arrival fix flows are described. Furthermore, multiple linear regression and regression tree ensemble learning approaches for translating multiple sector Weather Impacted Traffic Indexes (WITI) to EWR arrival meter fix throughputs are examined. These weather translation models are developed and validated using the EWR arrival flight and weather data for the period of April-September in 2014. This study also compares the performance of the regression tree ensemble with traditional multiple linear regression models for estimating the weather impacted throughputs at each of the EWR arrival meter fixes. For all meter fixes investigated, the results from the regression tree ensemble weather translation models show a stronger correlation between model outputs and observed meter fix throughputs than that produced from multiple linear regression method.

  17. Liquid ultrasonic flow meters for crude oil measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kalivoda, Raymond J.; Lunde, Per

    2005-07-01

    Liquid ultrasonic flow meters (LUFMs) are gaining popularity for the accurate measurement of petroleum products. In North America the first edition of the API standard ''Measurement of liquid hydrocarbons by ultrasonic flow meters using transit time technology'' was issued in February 2005. It addresses both refined petroleum products and crude oil applications. Its field of application is mainly custody transfer applications but it does provide general guidelines for the installation and operation of LUFM's other applications such as allocation, check meters and leak detection. As with all new technologies performance claims are at times exaggerated or misunderstood and application knowledge is limited. Since ultrasonic meters have no moving parts they appear to have fewer limitations than other liquid flow meters. Liquids ultrasonic flow meters, like turbine meters, are sensitive to fluid properties. It is increasingly more difficult to apply on high viscosity products then on lighter hydrocarbon products. Therefore application data or experience on the measurement of refined or light crude oil may not necessarily be transferred to measuring medium to heavy crude oils. Before better and more quantitative knowledge is available on how LUFMs react on different fluids, the arguments advocating reduced need for in-situ proving and increased dependency on laboratory flow calibration (e.g. using water instead of hydrocarbons) may be questionable. The present paper explores the accurate measurement of crude oil with liquid ultrasonic meters. It defines the unique characteristics of the different API grades of crude oils and how they can affect the accuracy of the liquid ultrasonic measurement. Flow testing results using a new LUFM design are discussed. The paper is intended to provide increased insight into the potentials and limitations of crude oil measurement using ultrasonic flow meters. (author) (tk)

  18. Checking liquid meters. Marketers find ''master meter program'' provides reliable, economical method to check truck meters

    Energy Technology Data Exchange (ETDEWEB)

    Lady, P.

    1976-08-01

    With LP-gas prices continuing to increase, LP-gas marketers are becoming increasingly aware of the need for testing liquid meters on trucks used for delivering bulk propane. Many large marketers are aware of the need for consistent testing and are establishing periodic programs for their truck fleets. Because the official test equipment--the volumetric meter power--is expensive and requires a highly trained operator, many dealers are seeking simpler, less expensive testing methods to make sure that their meters are dispensing fuel. The more accurate of the two alternative methods is a master meter which has been calibrated against a prover and whose variations are known for different flow rates. The method's main disadvantage is the possibility that the master meter might be in error. The last method, which uses truck scales, is the least expensive and most readily available to all operators but also is the least accurate and is time-consuming, especially in low-flow tests.

  19. Hybrid TLC-pair meter for the Sphinx Project

    Science.gov (United States)

    Wada, T.; Yamamoto, I.; Takahashi, N.; Misaki, A.

    1985-01-01

    The chief aims in THE SPHINX PROJECT are research of super lepton physics and new detector experiments. At the second phase of THE SPHINX PROJECT, a hybrid TLC-PAIR METER was designed for measuring high energy neutrino sources (E upsilon * TeV), searching high energy muon sources (E mu TeV) and measuring muon group (E mu 1 TeV). The principle of PAIR METER has been already proposed. In this TLC-PAIR METER, electromagnetic shower induced by cosmic ray muons are detected using TL (Thermoluminescence) sheets with position counters.

  20. Metering Wheel-Wire Track Wire Boom Deployment Mechanism

    Science.gov (United States)

    Granoff, Mark S.

    2014-01-01

    The NASA MMS Spin Plane Double Probe (SDP) Deployer utilizes a helical path, rotating Metering Wheel and a spring loaded Wire "Holding" Track to pay out a "fixed end" 57 meter x 1.5 mm diameter Wire Boom stored between concentric storage cylinders. Unlike rotating spool type storage devices, the storage cylinders remain stationary, and the boom wire is uncoiled along the length of the cylinder via the rotation of the Metering Wheel. This uncoiling action avoids the need for slip-ring contacts since the ends of the wire can remain stationary. Conventional fixed electrical connectors (Micro-D type) are used to terminate to operational electronics.

  1. X-ray intensifying screen visible light detection meter.

    Science.gov (United States)

    McLean, D; Eisenhuth, J; Knight, P; Bui, Q

    1997-06-01

    A light meter has been designed and built for the purpose of measuring the light emitted from an intensifying screen during x-ray irradiation. The meter uses a photodiode detector with a minimal drift amplification system. The meter repeatability was better than 0.5% and was found to be linear. A significant x-ray induced signal was recorded during measurement which needed to be subtracted from readings to deduce the intensification screen light output. The energy response of four screen types was subsequently measured.

  2. Topology-Based Estimation of Missing Smart Meter Readings

    Directory of Open Access Journals (Sweden)

    Daisuke Kodaira

    2018-01-01

    Full Text Available Smart meters often fail to measure or transmit the data they record when measuring energy consumption, known as meter readings, owing to faulty measuring equipment or unreliable communication modules. Existing studies do not address successive and non-periodical missing meter readings. This paper proposes a method whereby missing readings observed at a node are estimated by using circuit theory principles that leverage the voltage and current data from adjacent nodes. A case study is used to demonstrate the ability of the proposed method to successfully estimate the missing readings over an entire day during which outages and unpredictable perturbations occurred.

  3. Federal metering data analysis needs and existing tools

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, Jordan W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fowler, Kimberly M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-07-01

    Agencies have been working to improve their metering data collection, management, and analysis efforts over the last decade (since EPAct 2005) and will continue to address these challenges as new requirements and data needs come into place. Unfortunately there is no “one-size-fits-all” solution. As agencies continue to expand their capabilities to use metered consumption data to reducing resource use and improve operations, the hope is that shared knowledge will empower others to follow suit. This paper discusses the Federal metering data analysis needs and some existing tools.

  4. Open for new ideas. Metering management in the energy service sector; Offen fuer neue Ideen. Metering Management beim Energiedienst

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-10-04

    Smarter grids - this is one of the goals of the Rheinfelden energy service. At an early stage already, the energy service began to introduce new business processes like smart metering and related technologies, with an orientation along the requirements of the market and the pertinent legal regulations. A flexible software was used in metering management in order to best achieve the targeted goals. The energy service is now testing the applicability of DSL and GPRS in three smart meter field tests, each in a separate new housing area with different boundary conditions. (orig.)

  5. One-Meter Class Drilling for Planetary Exploration Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The purpose of the proposed effort is to understand and characterize the fundamental limitations of drilling one to three meters into challenging materials which may...

  6. Quantifying uncertainty contributions for fibre optic power meter calibrations

    CSIR Research Space (South Africa)

    Nel, M

    2009-09-01

    Full Text Available A fibre optic power meter calibration has several uncertainty contributors associated with it. In order to assign a realistic uncertainty to the calibration result it is necessary to realistically estimate the magnitude of each uncertainty...

  7. Electric Power Substitute Meter Management via Mobile Application

    Directory of Open Access Journals (Sweden)

    Nelson C. Rodelas

    2014-10-01

    Full Text Available EPSMvMA is composed of Digital Sub-Meter connected to different components namely the GSM module, Bluetooth module, Power Analyzer Module, LCD Module, Relay Module and Main Microcontroller module. The connection via Mobile is made possible by the modules mentioned. The software that the proponents will be dealing with in the study is C++ language, which will be used in programming the Main Microcontroller module and Visual Basic Language for the Android Phones. The Bluetooth module can access the Android Phones and connect to the digital sub-meter in a limited distance. The users will be at ease since a code embedded to the microcontroller will make the utility sub-meter produce the desired value of electricity (KWH and wherein the computed Sub-meter reading can be viewed through the LCD. This project is accommodating to those person that is always on the go and prudent.

  8. 100-Meter Resolution Satellite View of Hawaii - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Satellite View of Hawaii map layer is a 100-meter resolution simulated natural-color image of Hawaii. Vegetation is generally green, with forests in darker green...

  9. Tweeting : Smart meters raise awareness of energy consumption in buildings

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2009-11-15

    The University of Mississippi (UM) will monitor, analyze and report on energy consumption in its campus buildings in real-time using SmartSynch Smart Meters. The technology uses smart meter data to help identify a detailed pattern of electricity usage with the objective of finding methods to alter behaviour to reduce electricity usage and carbon emissions. SmartSynch installed 16 Smart Meters on campus with additional deployments being planned. The technology will enable the university to monitor energy consumption, track building power performance over time, compare building energy usage, and review the impact of the weather on energy use while reducing its carbon footprint. Additionally, UM will use Facebook, Twitter and an RSS feed to provide regular public updates on its buildings' energy consumption based on SmartSynch Smart Meter data. Each building will have its own profile on the social networking sites. 1 ref., 1 fig.

  10. 100-Meter Resolution Grayscale Shaded Relief of Hawaii - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Grayscale Shaded Relief of Hawaii map layer is a 100-meter resolution grayscale shaded relief image of Hawaii, in an Albers Equal-Area Conic projection. Shaded...

  11. 100-Meter Resolution Grayscale Shaded Relief of Alaska - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Grayscale Shaded Relief of Alaska map layer is a 100-meter resolution grayscale shaded relief image of Alaska, in an Albers Equal-Area Conic projection. Shaded...

  12. Lightweight Thermally Stable Multi-Meter Aperture Submillimeter Reflectors Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of the Phase II effort will be an affordable demonstrated full-scale design for a thermally stable multi-meter submillimeter reflector. The Phase I...

  13. Grayscale Hawaii Shaded Relief ? 200-Meter Resolution - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The grayscale Hawaii shaded relief data were derived from National Elevation Dataset (NED) data, and show the terrain of Hawaii at a resolution of 200 meters. The...

  14. ASTER Global Emissivity Dataset, 100 meter, Binary V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The AG100B.003 dataset was decommissioned as of December 14, 2016. Users are encouraged to use the ASTER Global Emissivity Dataset 100-meter (AG100.003 -...

  15. Guanabara Bay and Pecem LNG flexible metering systems

    Energy Technology Data Exchange (ETDEWEB)

    Torres, Vinicus Roberto C.; Carvalho, Gustavo L.A.; Bruel, Edson L.; Santana, Jose P.C. de; Vidal, Lud C.C.N. [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2009-12-19

    This work presents to the community the metering systems installed in the Liquefied Natural (LNG) Gas Flexible Terminals of the Pecem Port and Guanabara Bay. A brief description of the Terminals facilities and its operation is firstly made to provide a background of the systems discussed. Then, the LNG custody transfer metering system, the operational control metering system, the energy balance of the LNG transferring system and the Natural Gas custody transfer metering system - that are our systems of interest - are described in detail. It is intended to use the philosophy adopted in the Guanabara Bay and Pecem Flexible Terminals design as a standard to future installations, integrated with improvements brought by the operation experience that will be obtained in those terminals. (author)

  16. Suppression of radiated emission in fiscal taxi meter

    Science.gov (United States)

    He, Hong; Yang, Pei-pei; Su, Xing; Zhang, Da-jian; Wang, Ke-xi; Hou, Ming-feng

    2011-12-01

    This paper is based upon National Standards for EMC. For the problem that the intensity of electromagnetic radiation in the meter with the THG at 36MHz is seriously more than National Standards, by studying the theory of radiation emission and analyzing the formation mechanism of electromagnetic radiation interference, it proposes three restrain measures: 1.the improvement of the Crystal oscillator's grounding measure; 2.adding a RC filter circuit to the Crystal oscillator circuit; 3.the improvement of the tax's communication cable, solving the problem that radiation harassment the taxi meter seriously exceeds. The experimental result demonstrates that the radiation intensity of tax meter improved with the general measures meet the requirements of the national standard, making more than 32000 taxes in Tianjin install this green meter, protecting the safety of staff and normal operation of the surrounding equipment.

  17. 100-Meter Resolution Tree Canopy of Alaska - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer contains tree canopy data for Alaska, in an Albers Equal-Area Conic projection and at a resolution of 100 meters. The tree canopy data were derived...

  18. Color Alaska Shaded Relief ? 200-Meter Resolution - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The color Alaska shaded relief data were derived from National Elevation Dataset (NED) data, and show the terrain of Alaska at a resolution of 200 meters. The NED is...

  19. Color Hawaii Shaded Relief ? 200-Meter Resolution - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The color Hawaii shaded relief data were derived from National Elevation Dataset (NED) data, and show the terrain of Hawaii at a resolution of 200 meters. The NED is...

  20. 100-Meter Resolution Color Shaded Relief of Hawaii - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Color Shaded Relief of Hawaii map layer is a 100-meter resolution color-sliced elevation image of Hawaii, with relief shading added to accentuate terrain...

  1. 100-Meter Resolution Color Shaded Relief of Alaska - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Color Shaded Relief of Alaska map layer is a 100-meter resolution color-sliced elevation image of Alaska, with relief shading added to accentuate terrain...

  2. 100-Meter Resolution Satellite View of Alaska - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Satellite View of Alaska map layer is a 100-meter resolution simulated natural-color image of Alaska. Vegetation is generally green, with forests in darker green...

  3. Smarter energy from smart metering to the smart grid

    CERN Document Server

    Sun, Hongjian; Poor, H Vincent; Carpanini, Laurence; Fornié, Miguel Angel Sánchez

    2016-01-01

    This book presents cutting-edge perspectives and research results in smart energy spanning multiple disciplines across four main topics: smart metering, smart grid modeling, control and optimisation, and smart grid communications and networking.

  4. A Prediction-based Smart Meter Data Generator

    DEFF Research Database (Denmark)

    Iftikhar, Nadeem; Liu, Xiufeng; Nordbjerg, Finn Ebertsen

    2016-01-01

    With the prevalence of cloud computing and In-ternet of Things (IoT), smart meters have become one of the main components of smart city strategy. Smart meters generate large amounts of fine-grained data that is used to provide useful information to consumers and utility companies for decision......-making. Now-a-days, smart meter analytics systems consist of analytical algorithms that process massive amounts of data. These analytics algorithms require ample amounts of realistic data for testing and verification purposes. However, it is usually difficult to obtain adequate amounts of realistic data......, mainly due to privacy issues. This paper proposes a smart meter data generator that can generate realistic energy consumption data by making use of a small real-world dataset as seed. The generator generates data using a prediction-based method that depends on historical energy consumption patterns along...

  5. A Prediction-based Smart Meter Data Generator

    DEFF Research Database (Denmark)

    Iftikhar, Nadeem; Nordbjerg, Finn Ebertsen

    2016-01-01

    With the prevalence of cloud computing and Internet of Things (IoT), smart meters have become one of the main components of smart city strategy. Smart meters generate large amounts of fine-grained data that is used to provide useful information to consumers and utility companies for decisionmaking....... Now-a-days, smart meter analytics systems consist of analytical algorithms that process massive amounts of data. These analytics algorithms require ample amounts of realistic data for testing and verification purposes. However, it is usually difficult to obtain adequate amounts of realistic data......, mainly due to privacy issues. This paper proposes a smart meter data generator that can generate realistic energy consumption data by making use of a small real-world data set as seed. The generator generates data using a prediction-based method that depends on historical energy consumption patterns...

  6. Solutions For Smart Metering Under Harsh Environmental Condicions

    Directory of Open Access Journals (Sweden)

    Kunicina N.

    2015-02-01

    Full Text Available The described case study concerns application of wireless sensor networks to the smart control of power supply substations. The solution proposed for metering is based on the modular principle and has been tested in the intersystem communication paradigm using selectable interface modules (IEEE 802.3, ISM radio interface, GSM/GPRS. The solution modularity gives 7 % savings of maintenance costs. The developed solution can be applied to the control of different critical infrastructure networks using adapted modules. The proposed smart metering is suitable for outdoor installation, indoor industrial installations, operation under electromagnetic pollution, temperature and humidity impact. The results of tests have shown a good electromagnetic compatibility of the prototype meter with other electronic devices. The metering procedure is exemplified by operation of a testing company's workers under harsh environmental conditions.

  7. Solutions For Smart Metering Under Harsh Environmental Condicions

    Science.gov (United States)

    Kunicina, N.; Zabasta, A.; Kondratjevs, K.; Asmanis, G.

    2015-02-01

    The described case study concerns application of wireless sensor networks to the smart control of power supply substations. The solution proposed for metering is based on the modular principle and has been tested in the intersystem communication paradigm using selectable interface modules (IEEE 802.3, ISM radio interface, GSM/GPRS). The solution modularity gives 7 % savings of maintenance costs. The developed solution can be applied to the control of different critical infrastructure networks using adapted modules. The proposed smart metering is suitable for outdoor installation, indoor industrial installations, operation under electromagnetic pollution, temperature and humidity impact. The results of tests have shown a good electromagnetic compatibility of the prototype meter with other electronic devices. The metering procedure is exemplified by operation of a testing company's workers under harsh environmental conditions.

  8. Design and Implementation of Smart Electrical Power Meter System

    OpenAIRE

    Mofeed Turky Rashid

    2014-01-01

    In recent years, increased importance of Smart Grid, which includes monitoring and control the consumption of customers of electric power. In this paper, Wireless Smart Electrical Power Meter has been designed and implemented which ZigBee wireless sensor network (WSN) will be used for wireless electrical power meter communication supported by PIC microcontroller which used for power unit measurements. PIC microcontroller will be used for evaluating all electric power paramet...

  9. Remote calibration system of a smart electrical energy meter

    Directory of Open Access Journals (Sweden)

    Zakariae Jebroni

    2017-12-01

    Full Text Available The need to control the power grid in real time has opened a new field of research, today researchers are trying to design electrical meters that are completely remote controlled, to create an advanced metering infrastructure. One of the most important processes in the field of measurement is the calibration of measuring instruments. The calibration process of the electrical meters was performed at laboratories. However, the new directives, now, require a regular test of accuracy. Nevertheless, moving each time on site to check the accuracy of a meter can be annoying. To solve this problem our contribution is to propose a new structure of a smart meter that integrates a calibration card, so that, this process is carried out remotely. To be able to calibrate the meter or test its accuracy, we have included an AC-AC converter powered by the electrical grid and that provides a stable voltage independent of the electrical grid in term of frequency and amplitude. The output voltage of the converter is used as the reference signal during calibration or accuracy testing. In this paper, we will present the structure of the calibration card, the study and dimensioning of the converter, as well as the control technique used to eliminate variations of the input voltage. At the end, we will present the results of simulations and experiments.

  10. Tooth color measurement using Chroma Meter: techniques, advantages, and disadvantages.

    Science.gov (United States)

    Li, Yiming

    2003-01-01

    Tooth whitening has become a popular and routine dental procedure, and its efficacy and safety have been well documented. However, the measurement of tooth color, particularly in the evaluation of the efficacy of a system intended to enhance tooth whiteness, remains a challenge. One of the instruments used for assessing tooth color in clinical whitening studies is the Minolta Chroma Meter CR-321 (Minolta Corporation USA, Ramsey, NJ, USA). This article describes the instrument and discusses various measuring procedures and the Chroma Meter's advantages, limitations, and disadvantages. The available information indicates that, although Minolta Chroma Meter CR-321 provides quantitative and objective measurements of tooth color, it can be tedious to use with a custom alignment device. The Chroma Meter data are inconsistent with the commonly used visual instruments such as Vitapan Classical Shade Guide (Vita Zahnfabrik, Bad Säckingen, Germany), although in many cases the general trends are similar. It is also questionable whether the small area measured adequately represents the color of the whole tooth. A more critical challenge is the lack of methods for interpreting the Chroma Meter data regarding tooth color change in studies evaluating the efficacy of whitening systems. Consequently, at present the Chroma Meter data alone do not appear to be adequate for determining tooth color change in whitening research, although the quantitative measurements may be useful as supplemental or supportive data. Research is needed to develop and improve the instrument and technique for quantitative measurement of tooth color and interpretation of the data for evaluating tooth color change. This paper will help readers to understand the advantages and limitations of the Minolta Chroma Meter used for evaluating the efficacy of tooth-whitening systems so that proper judgment can be made in the interpretation of the results of clinical studies.

  11. Aesthetic and emotional effects of meter and rhyme in poetry.

    Science.gov (United States)

    Obermeier, Christian; Menninghaus, Winfried; von Koppenfels, Martin; Raettig, Tim; Schmidt-Kassow, Maren; Otterbein, Sascha; Kotz, Sonja A

    2013-01-01

    Metrical patterning and rhyme are frequently employed in poetry but also in infant-directed speech, play, rites, and festive events. Drawing on four line-stanzas from nineteenth and twentieth German poetry that feature end rhyme and regular meter, the present study tested the hypothesis that meter and rhyme have an impact on aesthetic liking, emotional involvement, and affective valence attributions. Hypotheses that postulate such effects have been advocated ever since ancient rhetoric and poetics, yet they have barely been empirically tested. More recently, in the field of cognitive poetics, these traditional assumptions have been readopted into a general cognitive framework. In the present experiment, we tested the influence of meter and rhyme as well as their interaction with lexicality in the aesthetic and emotional perception of poetry. Participants listened to stanzas that were systematically modified with regard to meter and rhyme and rated them. Both rhyme and regular meter led to enhanced aesthetic appreciation, higher intensity in processing, and more positively perceived and felt emotions, with the latter finding being mediated by lexicality. Together these findings clearly show that both features significantly contribute to the aesthetic and emotional perception of poetry and thus confirm assumptions about their impact put forward by cognitive poetics. The present results are explained within the theoretical framework of cognitive fluency, which links structural features of poetry with aesthetic and emotional appraisal.

  12. Additional functions of remotely read kWh-meters

    Energy Technology Data Exchange (ETDEWEB)

    Koponen, P. [VTT Energy, Espoo (Finland); Vehvilaeinen, S. [Mittrix Oy (Finland); Rantanen, J. [Helsinki Energy Board, Helsinki (Finland)

    1996-12-31

    In this presentation the possibilities to include new applications into remotely read smart kWh-meters are considered. New electronic meters can measure various electric quantities and have some extra calculating capacity. So they can be used to provide functions that distribution automation and the customer need and thus share the costs. Some applications like monitoring the state of the distribution network or locating faults are only for the utility, but many applications also need an interface to the customer or his automation system. Among those are monitoring the quality of electricity, estimating load curves, applying dynamic tariffs and selling electricity and accounting. As a special item, the continuous monitoring of the quality of electricity is discussed. This includes voltage levels, total distortion, asymmetry and so on. If such a kWh-meter indicates quality problems the situation can be detected with a suitable portable quality meter. The poor quality can be detected before it causes harm to equipment owned by the customers or the power distribution company. This presentation also presents a prototype of such a quality monitoring kWh-meter

  13. Aesthetic and emotional effects of meter and rhyme in poetry

    Directory of Open Access Journals (Sweden)

    Christian eObermeier

    2013-01-01

    Full Text Available Metrical patterning and rhyme are frequently employed in poetry but also in infant-directed speech, play, rites, and festive events. Drawing on four line-stanzas from 19th and 20th German poetry that feature end rhyme and regular meter, the present study tested the hypothesis that meter and rhyme have an impact on aesthetic liking, emotional involvement, and affective valence attributions. Hypotheses that postulate such effects have been advocated ever since ancient rhetoric and poetics, yet they have barely been empirically tested. More recently, in the field of cognitive poetics, these traditional assumptions have been readopted in a general cognitive framework. In the present experiment, we tested the influence of meter and rhyme as well as their interaction with lexicality in the aesthetic and emotional perception of poetry. Participants listened to stanzas that were systematically modified with regard to meter and rhyme and rated them. Both rhyme and regular meter led to enhanced aesthetic appreciation, higher intensity in processing, and more positively perceived and felt emotions, with latter finding being mediated by lexicality. Together these findings clearly show that both features significantly contribute to the aesthetic and emotional perception of poetry and thus confirm assumptions about their impact put forward by cognitive poetics. The present results are explained within the theoretical framework of cognitive fluency, which links structural features of poetry with aesthetic and emotional appraisal.

  14. Strategies for Power Line Communications Smart Metering Network Deployment

    Directory of Open Access Journals (Sweden)

    Alberto Sendin

    2014-04-01

    Full Text Available Smart Grids are becoming a reality all over the world. Nowadays, the research efforts for the introduction and deployment of these grids are mainly focused on the development of the field of Smart Metering. This emerging application requires the use of technologies to access the significant number of points of supply (PoS existing in the grid, covering the Low Voltage (LV segment with the lowest possible costs. Power Line Communications (PLC have been extensively used in electricity grids for a variety of purposes and, of late, have been the focus of renewed interest. PLC are really well suited for quick and inexpensive pervasive deployments. However, no LV grid is the same in any electricity company (utility, and the particularities of each grid evolution, architecture, circumstances and materials, makes it a challenge to deploy Smart Metering networks with PLC technologies, with the Smart Grid as an ultimate goal. This paper covers the evolution of Smart Metering networks, together with the evolution of PLC technologies until both worlds have converged to project PLC-enabled Smart Metering networks towards Smart Grid. This paper develops guidelines over a set of strategic aspects of PLC Smart Metering network deployment based on the knowledge gathered on real field; and introduces the future challenges of these networks in their evolution towards the Smart Grid.

  15. Advanced Metering Implementations - A Perspective from Federal Sector

    Energy Technology Data Exchange (ETDEWEB)

    Eaarni, Shankar

    2014-08-11

    Federal mandate (EPACT 2005) requires that federal buildings install advanced electrical meters-meters capable of providing data at least daily and measuring the consumption of electricity at least hourly. This work presents selected advanced metering implementations to understand some of the existing practices related to data capture and to understand how the data is being translated into information and knowledge that can be used to improve building energy and operational performance to meet federal energy reduction mandates. This study highlights case studies to represent some of the various actions that are being taken based on the data that are being collected to improve overall energy performance of these buildings. Some of these actions include- individualized tenant billing and energy forecasting, benchmarking, identifying energy conservation measures, measurement and verification.

  16. Privacy, technology, and norms: the case of Smart Meters.

    Science.gov (United States)

    Horne, Christine; Darras, Brice; Bean, Elyse; Srivastava, Anurag; Frickel, Scott

    2015-05-01

    Norms shift and emerge in response to technological innovation. One such innovation is Smart Meters - components of Smart Grid energy systems capable of minute-to-minute transmission of consumer electricity use information. We integrate theory from sociological research on social norms and privacy to examine how privacy threats affect the demand for and expectations of norms that emerge in response to new technologies, using Smart Meters as a test case. Results from three vignette experiments suggest that increased threats to privacy created by Smart Meters are likely to provoke strong demand for and expectations of norms opposing the technology and that the strength of these normative rules is at least partly conditional on the context. Privacy concerns vary little with actors' demographic characteristics. These findings contribute to theoretical understanding of norm emergence and have practical implications for implementing privacy protections that effectively address concerns of electricity users. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Deducing Energy Consumer Behavior from Smart Meter Data

    Directory of Open Access Journals (Sweden)

    Emad Ebeid

    2017-07-01

    Full Text Available The ongoing upgrade of electricity meters to smart ones has opened a new market of intelligent services to analyze the recorded meter data. This paper introduces an open architecture and a unified framework for deducing user behavior from its smart main electricity meter data and presenting the results in a natural language. The framework allows a fast exploration and integration of a variety of machine learning algorithms combined with data recovery mechanisms for improving the recognition’s accuracy. Consequently, the framework generates natural language reports of the user’s behavior from the recognized home appliances. The framework uses open standard interfaces for exchanging data. The framework has been validated through comprehensive experiments that are related to an European Smart Grid project.

  18. An electronic pressure-meter nociception paw test for mice

    Directory of Open Access Journals (Sweden)

    T.M. Cunha

    2004-03-01

    Full Text Available The aim of the present investigation was to describe and validate an electronic mechanical test for quantification of the intensity of inflammatory nociception in mice. The electronic pressure-meter test consists of inducing the animal hindpaw flexion reflex by poking the plantar region with a polypropylene pipette tip adapted to a hand-held force transducer. This method was compared to the classical von Frey filaments test in which pressure intensity is automatically recorded after the nociceptive hindpaw flexion reflex. The electronic pressure-meter and the von Frey filaments were used to detect time versus treatment interactions of carrageenin-induced hypernociception. In two separate experiments, the electronic pressure-meter was more sensitive than the von Frey filaments for the detection of the increase in nociception (hypernociception induced by small doses of carrageenin (30 µg. The electronic pressure-meter detected the antinociceptive effect of non-steroidal drugs in a dose-dependent manner. Indomethacin administered intraperitoneally (1.8-15 mg/kg or intraplantarly (30-300 µg/paw prevented the hypersensitive effect of carrageenin (100 µg/paw. The electronic pressure-meter also detected the hypernociceptive effect of prostaglandin E2 (PGE2; 10-100 ng in a dose-dependent manner. The hypernociceptive effect of PGE2 (100 ng was blocked by dipyrone (160 and 320 µg/paw but not by intraplantar administration of indomethacin (300 µg/paw. The present results validate the use of the electronic pressure-meter as more sensitive than the von Frey filaments in mice. Furthermore, it is an objective and quantitative nociceptive test for the evaluation of the peripheral antinociceptive effect of anti-inflammatory analgesic drugs, which inhibit prostaglandin synthesis (indomethacin or directly block the ongoing hypernociception (dipyrone.

  19. Optimal leaf positions for chlorophyll meter measurement in rice

    Directory of Open Access Journals (Sweden)

    Zhaofeng eYuan

    2016-05-01

    Full Text Available The Soil Plant Analysis Development (SPAD chlorophyll meter is one of the most commonly used diagnostic tools to measure crop nitrogen status. However, the measurement method of the meter could significantly affect the accuracy of the final estimation. Thus, this research was undertaken to develop a new methodology to optimize SPAD meter measurements in rice (Oryza sativa L.. A flatbed color scanner was used to map the dynamic chlorophyll distribution and irregular leaf shapes. Calculus algorithm was adopted to estimate the potential positions for SPAD meter measurement along the leaf blade. Data generated by the flatbed color scanner and SPAD meter were analysed simultaneously. The results suggested that a position 2/3 of the distance from the leaf base to the apex (2/3 position could represent the chlorophyll content of the entire leaf blade, as indicated by the relatively low variance of measurements at that positon. SPAD values based on di-positional leaves and the extracted chlorophyll a and b contents were compared. This comparison showed that the 2/3 position on the lower leaves tended to be more sensitive to changes in chlorophyll content. Finally, the 2/3 position and average SPAD values of the fourth fully expanded leaf from the top were compared with leaf nitrogen concentration. The results showed the 2/3 position on that leaf was most suitable for predicting the nitrogen status of rice. Based on these results, we recommend making SPAD measurements at the 2/3 position on the fourth fully expanded leaf from the top. The coupling of dynamic chlorophyll distribution and irregular leaf shapes information can provide a promising approach for the calibration of SPAD meter measurement, which can further benefit the in situ nitrogen management by providing reliable estimation of crops nitrogen nutrition status.

  20. Accidental Cutaneous Burns Secondary to Salbutamol Metered Dose Inhaler

    OpenAIRE

    Kale, Ashutosh; Shackley, Fiona

    2010-01-01

    We report a case of accidental cutaneous burns caused by salbutamol metered dose inhaler. A 9-year-old boy underwent dental extraction at a children's hospital and was incidentally noted to have burn injuries on dorsum of both hands. On questioning, the boy revealed that a few days ago his 14-year-old brother, who is an asthmatic, playfully sprayed his salbutamol metered dose inhaler on the back of both his hands with the inhaler's mouth piece being in direct contact with the patient's skin. ...

  1. Additional functions of remotely read kWh-meters

    Energy Technology Data Exchange (ETDEWEB)

    Koponen, P. [VTT Energy, Espoo (Finland); Vehvilaeinen, S. [Mittrix Oy (Finland); Rantanen, J. [Helsinki Energy Board (Finland)

    1998-08-01

    In this chapter the possibilities to include new applications into remotely read smart kWh-meters are considered. New electronic meters can measure various electric quantities and have some extra calculating capacity. So they can be used to provide functions that distribution automation and the customer need and thus share the costs. Some applications like monitoring the state of the distribution network or locating faults are only for the utility, but many applications also need an interface to the customers or their automation systems. Among those are monitoring the quality of electricity, estimating load curves, applying dynamic tariffs and selling electricity and accounting. As a special item, the continuous monitoring of the quality of electricity is discussed. This includes voltage levels, total distortion, asymmetry and so on. If such a kWh-meter indicates quality problems it is possible to go there with a portable quality meter that is suitable for the case and inspect the situation. The poor quality can be detected before it causes harm to equipment owned by the customers or the power distribution company. This article also presents a prototype of such a quality monitoring kWh-meter. Dynamic tariffs and free electricity markets require two way communication with the utility and the customer and measurement of the time variations of the energy consumption. The customers or their energy management system must receive the energy prices from the utility and calculate the energy costs and decide upon the energy consumption control actions. Some alternative ways to meet these customer interface requirements are compared. Remote reading of kWh-meters requires a certain investment in meters and their data communication with the utility. Because smart meters can have some additional memory and calculating capacity and are capable of measuring various electric quantities, it is possible to share the costs with other applications that use the same hardware and data

  2. Apparent losses due to domestic water meter under-registration in ...

    African Journals Online (AJOL)

    By combining these results with the average age of meters in South Africa, estimated from the National Water Demand Archive, it was possible to estimate the average meter under-registration due to meter aging. The study concluded that apparent losses due to water meter under-registration are around 5% of consumption ...

  3. Apparent losses due to domestic water meter under-registration in ...

    African Journals Online (AJOL)

    2015-10-05

    Oct 5, 2015 ... By combining these results with the average age of meters in South Africa, estimated from the National Water Demand. Archive, it was possible to estimate the average meter under-registration due to meter aging. The study concluded that apparent losses due to water meter under-registration are around ...

  4. Apparent losses due to domestic water meter under-registration in ...

    African Journals Online (AJOL)

    2015-10-05

    Oct 5, 2015 ... with the exception of one multi-jet meter. These meters were distributed in 15 and 6 different suburbs in Cape Town and. Mangaung, respectively. The reading taken from water meters in these tests included meter errors, and thus had to be corrected to determine the actual volumes. These corrections were ...

  5. Current meter data from moored current meter casts in the South Atlantic Ocean from 18 June 1992 - 29 October 1993 (NODC Accession 9700223)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the South Atlantic Ocean from June 18, 1992 to October 29, 1993. Data were submitted by Oregon...

  6. Current meter and temperature profile data from moored current meter casts in the TOGA area - Atlantic Ocean from 10 September 1970 - 27 October 1980 (NODC Accession 8600320)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter and temperature profile data were collected using moored current meter - PCM casts in the TOGA area - Atlantic Ocean from September 10, 1970 to October...

  7. Current meter data from moored current meter casts in the Northeast Pacific (limit - 180) from 1992-06-12 to 1994-06-20 (NODC Accession 9700237)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Northeast Pacific (limit - 180) from June 12, 1992 to June 20, 1994. Data were submitted by...

  8. Security and functional requirements for the smart meter gateway; Sicherheitstechnische Vorgaben und funktionale Anforderungen an das Smart Meter Gateway

    Energy Technology Data Exchange (ETDEWEB)

    Bast, Holger; Vollmer, Stefan [Bundesamt fuer Sicherheit in der Informationstechnik, Bonn (Germany)

    2012-07-01

    The availability of smart metering for the majority of both private and corporate prosumers is an essential precondition to get smart grids into operation. However, several concerns about data protection and security issues of smart meters have been raised and discussed in German media. The German Federal Data Protection Commissioner argued that without any further precautions personal data processed in smart meters could be collected and misused by unauthorized third parties if there is no technical standard that specifies technical requirements for necessary data security functions combined with regulatory instruments to make them mandatory. The German Federal Office for Information Security develops a protection profile based on Common Criteria and Technical Guidelines that allow a comparable security certification of such devices. (orig.)

  9. Look at the Beat, Feel the Meter:Top-down Effects of Meter Induction on Auditory and Visual Modalities

    Directory of Open Access Journals (Sweden)

    Alexandre eCelma-Miralles

    2016-03-01

    Full Text Available Recent research has demonstrated top-down effects on meter induction in the auditory modality. However, little is known about these effects in the visual domain, especially without the involvement of motor acts such as tapping. In the present study, we aim to assess whether the projection of meter on auditory beats is also present in the visual domain. We asked sixteen musicians to internally project binary (i.e. a strong-weak pattern and ternary (i.e. a strong-weak-weak pattern meter onto separate, but analogue, visual and auditory isochronous stimuli. Participants were presented with sequences of tones or blinking circular shapes (i.e. flashes at 2.4 Hz while their electrophysiological responses were recorded. A frequency analysis of the elicited steady-state evoked potentials allowed us to compare the frequencies of the beat (2.4 Hz, its first harmonic (4.8 Hz, the binary subharmonic (1.2 Hz, and ternary subharmonic (0.8 Hz within and across modalities. Taking the amplitude spectra into account, we observed an enhancement of the amplitude at 0.8 Hz in the ternary condition for both modalities, suggesting meter induction across modalities. There was an interaction between modality and voltage at 2.4 and 4.8 Hz. Looking at the power spectra, we also observed significant differences from zero in the auditory, but not in the visual, binary condition at 1.2 Hz. These findings suggest that meter processing is modulated by top-down mechanisms that interact with our perception of rhythmic events and that such modulation can also be found in the visual domain. The reported cross-modal effects of meter may shed light on the origins of our timing mechanisms, partially developed in primates and allowing humans to synchronize across modalities accurately.

  10. How to Make the 20-cent Fallout Meter

    Energy Technology Data Exchange (ETDEWEB)

    Meade, Roger Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rodriguez, Serena R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Alvarez, Luis [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-17

    Nobel Prize winner Luis Alvarez published an article on how to build a homemade fallout meter in the November 12, 1961, issue of the Sunday supplement This Week Magazine. A yellowed copy of the article was recently found in the files of the Radiochemistry Group, C-NR, and is reproduced below in its original form.

  11. Concepten nul op de meter en 80% besparing

    NARCIS (Netherlands)

    Jacobs, P.; Liedelmeijer, K.; Borsboom, W.A.; Vliet, M.R.A. van; Jong, P. de

    2015-01-01

    Bouwers die kiezen voor energiezuinig en Nul op de Meter staan voor een aantal uitdagingen. Zowel op sociaal, economisch en technisch gebied is er werk aan de winkel. Er wordt al gepionierd en daar kunnen we van leren. Daarom delen wij, TNO, RIGO, Van Beek, Energiesprong | Platform 31, met plezier

  12. INFLUENCE OF FUNCTIONAL ABILITY IN RUNNING 400 AND 800 METERS

    Directory of Open Access Journals (Sweden)

    Abdulla Elezi

    2013-07-01

    Full Text Available Goal of the research was to assess on the grounds of data collected that were used to assess the functional ability of the cardio-respiratory system and the results of running to determine the relation of these sum of variables. Basic statistical indicators of the physiological variables and results of running were calculated. For determining the relation, the regression analysis was used in the manifested space. Criterion variable (running for 100 meters did not demonstrate statistically significant coefficient of multiple variation with predictor variables. The time span in running 400 meters is short in order to engage mechanisms that supply and transform the energy for oxidative processes. Criterion variable (of running 800 meters has demonstrated statistically significant coefficient of multiple correlations with predictor variable and its value was 0.377 tested through F-test. This is understandable given that the time effect of engagement of systems responsible for transfer and transformation of energy compared to time needed for running 400 meters.

  13. A Status Report on the Thirty Meter Telescope Adaptive Optics ...

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... We provide an update on the recent development of the adaptive optics (AO) systems for the Thirty Meter Telescope (TMT) since mid-2011. The first light AO facility for TMT consists of the Narrow Field Infra-Red AO System (NFIRAOS) and the associated Laser Guide Star Facility (LGSF). This order 60 × 60 ...

  14. 40 CFR 1065.230 - Raw exhaust flow meter.

    Science.gov (United States)

    2010-07-01

    ... flow meter. (a) Application. You may use measured raw exhaust flow, as follows: (1) Use the actual... value: (i) For feedback control of a proportional sampling system, such as a partial-flow dilution... averaging Pitot tube, a hot-wire anemometer, or other measurement principle. This would generally not...

  15. 16 reference population equations using peak expiratory flow meters

    African Journals Online (AJOL)

    DR. AMINU

    produced using PEF meters in Nigeria. 2. To highlight on the limitations observed on some of these population driven reference equations. 3. To suggest other methods to improve on the reference equations produced. Contribution of Scholars in generating PEFR prediction equations in Nigeria. Normal values of PEFR ...

  16. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    Enrique

    between radiation doses absorbed by health care workers and dose area product meter (DAP) measurements at Universitas Hospital, Bloemfontein. The DAP is an instrument which accurately measures the radiation emitted from the source. The study included the interventional radiolo- gists, radiographers and nurses ...

  17. Accuracy of Handheld Blood Glucose Meters at High Altitude

    NARCIS (Netherlands)

    de Mol, Pieter; Krabbe, Hans G.; de Vries, Suzanna T.; Fokkert, Marion J.; Dikkeschei, Bert D.; Rienks, Rienk; Bilo, Karin M.; Bilo, Henk J. G.

    2010-01-01

    Background: Due to increasing numbers of people with diabetes taking part in extreme sports (e. g., high-altitude trekking), reliable handheld blood glucose meters (BGMs) are necessary. Accurate blood glucose measurement under extreme conditions is paramount for safe recreation at altitude. Prior

  18. Smart Grid Security A Smart Meter-Centric Perspective

    DEFF Research Database (Denmark)

    Vigo, Roberto; Yuksel, Ender; Ramli, Carroline Dewi Puspa Kencana

    2012-01-01

    , leading to what is known as the Smart Grid. The development of this Cyber-Physical System introduces new security issues, thus calling for efforts in studying possible attacks and devising suitable countermeasures. In this paper, we review a generic model for the Smart Grid, and present possible attacks...... and countermeasures focusing on a key component of the Smart Grid: the Smart Meter....

  19. Minnesota Digital Elevation Model - Tiled 30 Meter Resolution

    Data.gov (United States)

    Minnesota Department of Natural Resources — This 30 Meter DEM is a copy of the USGS 1:24,000 scale Level 2 DEMs for the State. There are three quadrangles known be be Level 1 DEM data: Town Line Lake (q1925),...

  20. An assessment of billing electricity consumers via analogue meters ...

    African Journals Online (AJOL)

    This paper assesses the perception of billing consumers via analogue meter in Kano Electricity Distribution Plc, Nigeria. Questionnaire survey was used to collect data from the consumers, frequency counts and percentages were used to analyze the generated data. The result of the study revealed that 38% of the Analogue ...

  1. Ipratropium bromide delivered by metered-dose aerosol to infant ...

    African Journals Online (AJOL)

    Two methods of administration of ipratropium bromide (Atrovent; Boehringer Ingelheim) to wheezing children'< 25 months of age were compared: (i) the conventional nebulisation (15 children); and (ii) a metered-dose aerosol plus spacer and mask (MDA group, 17 children). The drug induced a significant and similar fall in ...

  2. Meter Detection in Symbolic Music Using Inner Metric Analysis

    NARCIS (Netherlands)

    de Haas, W.B.; Volk, A.

    2016-01-01

    In this paper we present PRIMA: a new model tailored to symbolic music that detects the meter and the first downbeat position of a piece. Given onset data, the metrical structure of a piece is interpreted using the Inner Metric Analysis (IMA) model. IMA identifies the strong and weak metrical

  3. Ipratropium bromide delivered by metered-dose aerosol to infant ...

    African Journals Online (AJOL)

    1990-08-21

    Aug 21, 1990 ... metered aerosol method compared with nebulisation of ipra- tropium bromide when given to wheezing infants and toddlers. The former method is convenient for primary health care facilities or home use, since it does not depend upon the availability of the nebuliser apparatus or a gas or electricity source.

  4. Chlorophyll meter reading and total nitrogen content applied as ...

    African Journals Online (AJOL)

    The present study was aimed to assess the relationship between the reading of the chlorophyll meter and the total nitrogen (N) content in the leaf in different parts of the crambe plant, depending on the doses of nitrogen applied to the canopy. Randomized block design in a split plot experimental design was used. The plots ...

  5. Chlorophyll meter reading and total nitrogen content applied as ...

    African Journals Online (AJOL)

    Ana Mascarello

    The present study was aimed to assess the relationship between the reading of the chlorophyll meter and the total nitrogen (N) content in the leaf in different parts of the crambe plant, depending on the doses of nitrogen applied to the canopy. Randomized block design in a split-plot experimental design was used. The plots ...

  6. Index of Refraction Measurements Using a Laser Distance Meter

    Science.gov (United States)

    Ochoa, Romulo; Fiorillo, Richard; Ochoa, Cris

    2014-01-01

    We present a simple method to determine the refractive indices of transparent media using a laser distance meter. Indices of refraction have been obtained by measuring the speed of light in materials. Some speed of light techniques use time-of-flight measurements in which pulses are emitted by lasers and the time interval is measured for the pulse…

  7. Vibration isolation for Coriolis Mass-Flow meters

    NARCIS (Netherlands)

    van de Ridder, Bert

    2015-01-01

    A Coriolis Mass-Flow Meter (CMFM) is an active device based on the Coriolis force principle for direct mass-flow measurements, with high accuracy, range-ability and repeatability. The working principle of a CMFM is as follows: a fluid conveying tube is actuated to oscillate at a low amplitude. A

  8. Design and construction of a resistivity meter for shallow investigation

    African Journals Online (AJOL)

    Beyond this spread, the difference in readings is much. Hence, the use of this system is limited to shallow investigations where the target depth is not more than fifty metres (50m). Efforts are being made to improve on its performance. Keywords: Design and construction, resistivity meter and field testing. Nigerian Journal of ...

  9. Multichannel Distribution Meter: A Veritable Solution in Power ...

    African Journals Online (AJOL)

    Power theft in partitioned commercial apartments, especially in the form of unpaid bills due to disputes, is a major challenge to revenue recovery in the power sector. This paper presents a multi-channel power distribution metering solution that serves to resolve disputes among users in partitioned apartments, and between ...

  10. Performance evaluation of cognitive radio in advanced metering infrastructure communication

    Science.gov (United States)

    Hiew, Yik-Kuan; Mohd Aripin, Norazizah; Din, Norashidah Md

    2016-03-01

    Smart grid is an intelligent electricity grid system. A reliable two-way communication system is required to transmit both critical and non-critical smart grid data. However, it is difficult to locate a huge chunk of dedicated spectrum for smart grid communications. Hence, cognitive radio based communication is applied. Cognitive radio allows smart grid users to access licensed spectrums opportunistically with the constraint of not causing harmful interference to licensed users. In this paper, a cognitive radio based smart grid communication framework is proposed. Smart grid framework consists of Home Area Network (HAN) and Advanced Metering Infrastructure (AMI), while AMI is made up of Neighborhood Area Network (NAN) and Wide Area Network (WAN). In this paper, the authors only report the findings for AMI communication. AMI is smart grid domain that comprises smart meters, data aggregator unit, and billing center. Meter data are collected by smart meters and transmitted to data aggregator unit by using cognitive 802.11 technique; data aggregator unit then relays the data to billing center using cognitive WiMAX and TV white space. The performance of cognitive radio in AMI communication is investigated using Network Simulator 2. Simulation results show that cognitive radio improves the latency and throughput performances of AMI. Besides, cognitive radio also improves spectrum utilization efficiency of WiMAX band from 5.92% to 9.24% and duty cycle of TV band from 6.6% to 10.77%.

  11. Exploring the energy benefits of advanced water metering

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Michael A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hans, Liesel [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Piscopo, Kate [Univ. of California, Berkeley, CA (United States); Sohn, Michael D. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-08-01

    Recent improvements to advanced water metering and communications technologies have the potential to improve the management of water resources and utility infrastructure, benefiting both utilities and ratepayers. The highly granular, near-real-time data and opportunity for automated control provided by these advanced systems may yield operational benefits similar to those afforded by similar technologies in the energy sector. While significant progress has been made in quantifying the water-related benefits of these technologies, the research on quantifying the energy benefits of improved water metering is underdeveloped. Some studies have quantified the embedded energy in water in California, however these findings are based on data more than a decade old, and unanimously assert that more research is needed to further explore how topography, climate, water source, and other factors impact their findings. In this report, we show how water-related advanced metering systems may present a broader and more significant set of energy-related benefits. We review the open literature of water-related advanced metering technologies and their applications, discuss common themes with a series of water and energy experts, and perform a preliminary scoping analysis of advanced water metering deployment and use in California. We find that the open literature provides very little discussion of the energy savings potential of advanced water metering, despite the substantial energy necessary for water’s extraction, conveyance, treatment, distribution, and eventual end use. We also find that water AMI has the potential to provide water-energy co-efficiencies through improved water systems management, with benefits including improved customer education, automated leak detection, water measurement and verification, optimized system operation, and inherent water and energy conservation. Our findings also suggest that the adoption of these technologies in the water sector has been slow

  12. In-Vacuum Photogrammetry of a 10-Meter Solar Sail

    Science.gov (United States)

    Meyer, Chris G.; Jones, Thomas W.; Lunsford, Charles B.; Pappa, Richard S.

    2005-01-01

    In July 2004, a 10-meter solar sail structure developed by L Garde, Inc. was tested in vacuum at the NASA Glenn 30-meter Plum Brook Space Power Facility in Sandusky, Ohio. The three main objections of the test were to demonstrate unattended deployment from a stowed configuration, to measure the deployed shape of the sail at both ambient and cryogenic room temperatures, and to measure the deployed structural dynamic characteristics (vibration modes). This paper summarizes the work conducted to fulfill the second test objective. The deployed shape was measured photogrammetrically in vacuum conditions with four 2-megapixel digital video cameras contained in custom made pressurized canisters. The canisters included high-intensity LED ring lights to illuminate a grid of retroreflective targets distributed on the solar sail. The test results closely matched pre-test photogrammetry numerical simulations and compare well with ABAQUS finite-element model predictions.

  13. Digital Metering System of New Generation Smart Substation in China

    Directory of Open Access Journals (Sweden)

    Bai Jingfen

    2016-01-01

    Full Text Available The new generation of smart substation is a summary and improvement of the earlier intelligent substations within the past 5 years. As a part of the substation operation function, the electric energy metering system must adapt to the requirements of the new generation smart substation which is more intelligent, full digitalization, networked and integrated. With the features of digitized, easy information sharing, and hardware shared, the digital measurement system is the inevitable choice for the new generation smart substation. This paper is the first literature to introduce the concept and structure of the digital metering system. The composition and technical characteristics of the new generation Smart Substation measurement system are introduced in detail.

  14. Mobile metering. Enabling cost-efficient smart charging for EVs

    Energy Technology Data Exchange (ETDEWEB)

    Hechtfischer, Knut; Pawlitschek, Frank [ubitricity GmbH, Berlin (Germany); Berg, Andreas [VOLTARIS, Merzig (Germany)

    2012-07-01

    Users of electric vehicles want to and should be mobile with the least possible limitations. A fundamental requirement is an affordable and easy to use charging infrastructure that allows charging of the vehicle, if achievable wherever the EV is parked. ubitricity and VOLTARIS are developing and testing the On-Board Metering system and the underlying business and security concepts for such an ubiquitous charging infrastructure for electric mobility. Further leading partners are supporting the project that is being co-funded by research grants of the German Federal Ministry of Economics and Technology. The basic idea is to install metering and communication technology inside the car to generate the information required for billing processes. (orig.)

  15. Handheld Multi-Gas Meters Market Survey Report

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Gustavious [Brigham Young Univ., Provo, UT (United States); Wald-Hopkins, Mark David [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Obrey, Stephen J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Akhadov, Valida Dushdurova [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-23

    Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the chemical monitored. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. To provide emergency responders with information on handheld multi-gas meters, the System Assessment and Validation for Emergency Responders (SAVER) Program conducted a market survey. This market survey report is based on information gathered between November 2015 and February 2016 from vendors, Internet research, industry publications, an emergency responder focus group, and a government issued Request for Information (RFI) that was posted on the Federal Business Opportunities website.

  16. Visualization Techniques for Electrical Grid Smart Metering Data: A Survey

    DEFF Research Database (Denmark)

    Stefan, Maria; Lopez, Jose Manuel Guterrez Lopez; Andreasen, Morten Henius

    2017-01-01

    One of the considerable initiatives towards creating a smart society could be the guarantee of a smart, resilient and reliable power grid. As an attempt to improve the electricity supply service, it would be meaningful for the distributed system operators (DSOs) to be able to monitor the current...... constitute the baseline for bringing improvements to the power grid. This paper presents an approach to build an efficient visualization system so that the extracted smart meters information can be used in a meaningful manner. An overview of the use cases related to the visualization features is first...... status of the grid. The prediction of future possible critical situations would then be feasible using the available information, whereas, based on historical data, further grid expansion and reinforcement may be planned. A proper presentation and visualization of the near-real time metering data may...

  17. Development of on-board fuel metering and sensing system

    Science.gov (United States)

    Hemanth, Y.; Manikanta, B. S. S.; Thangaraja, J.; Bharanidaran, R.

    2017-11-01

    Usage of biodiesel fuels and their blends with diesel fuel has a potential to reduce the tailpipe emissions and reduce the dependence on crude oil imports. Further, biodiesel fuels exhibit favourable greenhouse gas emission and energy balance characteristics. While fossil fuel technology is well established, the technological implications of biofuels particularly biodiesel is not clearly laid out. Hence, the objective is to provide an on-board metering control in selecting the different proportions of diesel and bio-diesel blends. An on-board fuel metering system is being developed using PID controller, stepper motors and a capacitance sensor. The accuracy was tested with the blends of propanol-1, diesel and are found to be within 1.3% error. The developed unit was tested in a twin cylinder diesel engine with biodiesel blended diesel fuel. There was a marginal increase (5%) in nitric oxide and 14% increase in smoke emission with 10% biodiesel blended diesel at part load conditions.

  18. Distribution system intelligent state estimation through minimal meter placement

    Energy Technology Data Exchange (ETDEWEB)

    Ramesh, L. [Jadavpur Univ., Kolkata (India). Dept. of Electrical Engineering; Chowdhury, S.; Chowdhury, S.P.; Gaunt, C.T. [Cape Town Univ. (South Africa)

    2009-03-11

    A method of accurately estimating electrical parameters for distribution automation systems in power distribution networks was presented. A particle swarm optimization (PSO) algorithm was used to identify meter locations as well as to monitor and estimate parameters in the distribution system. The determined locations were then used to monitor and estimate parameters using a SCADA system arrangement. Parameter values were estimated using a hybrid artificial neural network (ANN) based estimation technique where pseudo-measurements were injected at un-metered buses. An Institute of Electrical and Electronic Engineers (IEEE) 13-node system with a distribution system used by the Tamil Nadu Electrical Board in India was used to verify the method. Results of the study showed that the proposed algorithm can be used to accurately estimate the electrical parameters of distribution automation systems. The method will be used to determine the position of future switch position and transformer locations. 22 refs., 1 tab., 6 figs.

  19. Analysis of FDML lasers with meter range coherence

    Science.gov (United States)

    Pfeiffer, Tom; Draxinger, Wolfgang; Wieser, Wolfgang; Klein, Thomas; Petermann, Markus; Huber, Robert

    2017-02-01

    FDML lasers provide sweep rates in the MHz range at wide optical bandwidths, making them ideal sources for high speed OCT. Recently, at lower speed, ultralong-range swept-source OCT has been demonstrated using a tunable vertical cavity surface emitting laser (VCSEL) and also using a Vernier-tunable laser. These sources provide relatively high sweep rates and meter range coherence lengths. In order to achieve similar coherence, we developed an extremely well dispersion compensated Fourier Domain Mode Locked (FDML) laser, running at 3.2 MHz sweep rate and 120 nm spectral bandwidth. We demonstrate that this laser offers meter range coherence and enables volumetric long range OCT of moving objects.

  20. GARUSO - Version 1.0. Uncertainty model for multipath ultrasonic transit time gas flow meters

    Energy Technology Data Exchange (ETDEWEB)

    Lunde, Per; Froeysa, Kjell-Eivind; Vestrheim, Magne

    1997-09-01

    This report describes an uncertainty model for ultrasonic transit time gas flow meters configured with parallel chords, and a PC program, GARUSO Version 1.0, implemented for calculation of the meter`s relative expanded uncertainty. The program, which is based on the theoretical uncertainty model, is used to carry out a simplified and limited uncertainty analysis for a 12`` 4-path meter, where examples of input and output uncertainties are given. The model predicts a relative expanded uncertainty for the meter at a level which further justifies today`s increasing tendency to use this type of instruments for fiscal metering of natural gas. 52 refs., 15 figs., 11 tabs.

  1. PELATIHAN LARI INTERVAL 4 X 50 METER DI PANTAI BERPASIR LEBIH MENINGKATKAN KECEPATAN LARI 100 METER DARIPADA PELATIHAN LARI INTERVAL 4 X 50 METER DI LAPANGAN PADA SISWA KELAS XSMK N KAKULUK MESAK NTT.

    OpenAIRE

    Benediktus Nahak; Alex Pangkahila; Susy Purnawati

    2014-01-01

    The speed is one of the biomotoriccomponents which dominantin the run race100 meters. 100 meters run is part of athletics which has a short duration, highintensity and anaerobic systems develop. The purpose of this study was todetermine the increasing of 100 meter run speed, therefore this research is anexperimental study was conducted in SMK N Kakulukmesak Belu regency NTT,for 6 months from March - May 2014, with the frequency of exercise 3 times aweek. This study uses two types of training,...

  2. Security Challenges in Smart-Grid Metering and Control Systems

    OpenAIRE

    Xinxin Fan; Guang Gong

    2013-01-01

    The smart grid is a next-generation power system that is increasingly attracting the attention of government, industry, and academia. It is an upgraded electricity network that depends on two-way digital communications between supplier and consumer that in turn give support to intelligent metering and monitoring systems. Considering that energy utilities play an increasingly important role in our daily life, smart-grid technology introduces new security challenges that must be addressed. Depl...

  3. Data acquisition and meter unit based in wifi communication protocol

    Directory of Open Access Journals (Sweden)

    Gerardo Cázarez Ayala

    2012-05-01

    Full Text Available Without doubt, the competitive fast rhythm of the industries is one of the main causes helped bring to the accelerated growth of the electronic technology and the communication. The need to develop new products with a best quality, cheaper and faster as assure and increase the quality of the products in the international markets, requires of new technologies to the metering, monitoring and control of their production processes, of which finality is to improve the processes to guaranteed their products in the market in the less time possible, the best quality and low cost for the final consumer. This work is based in the design and implementation of a Wireless Data Acquisition Unit based in WiFi protocol, which is oriented to meter, monitoring and the control of processes in the industry, commercial and the home automation applications, using one of the wirelessprotocols with the biggest acceptance in the market, with the main objective of to take advantage of the installed physical infrastructure in the place of the application, like industry, company or house. The Unit is based in the RN-131G, a Roving Network company module, which is able to work in stand-alone mode with ultralow power consummation and supporting the IEEE 802.11b/g protocols, in which is possible to achieve transfer rates of up to 11 Mbps and 54 Mbps in /b & /g specifications respectively. Whit this unit is possible to meter up to 5 analogs signals with 14 bits precision and has include a temperature and relative humidity sensors. This unit can meter two digital signals and act mean two digitals outputs, and gas include an USB port for communication and programming tasks.

  4. Experimental and numerical investigation of thermal flow meter

    Directory of Open Access Journals (Sweden)

    Cebula Artur

    2015-09-01

    Full Text Available The paper presents analytical and numerical model calculation results of the temperature distribution along the thermal flow meter. Results show a very good conformity between numerical and analytical model. Apart from the calculation results the experimental investigations are presented. The author performed the test where a temperature of duct wall surface was measured. The relation between mass flow rate in terms of the duct surface temperature difference was developed.

  5. INFLUENCE OF FUNCTIONAL ABILITY IN RUNNING 400 AND 800 METERS

    OpenAIRE

    Abdulla Elezi; Hasim Rushiti; Afrim Koca

    2013-01-01

    Goal of the research was to assess on the grounds of data collected that were used to assess the functional ability of the cardio-respiratory system and the results of running to determine the relation of these sum of variables. Basic statistical indicators of the physiological variables and results of running were calculated. For determining the relation, the regression analysis was used in the manifested space. Criterion variable (running for 100 meters) did not demonstrate statistically si...

  6. Strategies for Power Line Communications Smart Metering Network Deployment

    OpenAIRE

    Alberto Sendin; Ivan Peña; Pablo Angueira

    2014-01-01

    Smart Grids are becoming a reality all over the world. Nowadays, the research efforts for the introduction and deployment of these grids are mainly focused on the development of the field of Smart Metering. This emerging application requires the use of technologies to access the significant number of points of supply (PoS) existing in the grid, covering the Low Voltage (LV) segment with the lowest possible costs. Power Line Communications (PLC) have been extensively used in electricity grids ...

  7. An alternative arrangement of metered dosing fluid using centrifugal pump

    Science.gov (United States)

    Islam, Md. Arafat; Ehsan, Md.

    2017-06-01

    Positive displacement dosing pumps are extensively used in various types of process industries. They are widely used for metering small flow rates of a dosing fluid into a main flow. High head and low controllable flow rates make these pumps suitable for industrial flow metering applications. However their pulsating flow is not very suitable for proper mixing of fluids and they are relatively more expensive to buy and maintain. Considering such problems, alternative techniques to control the fluid flow from a low cost centrifugal pump is practiced. These include - throttling, variable speed drive, impeller geometry control and bypass control. Variable speed drive and impeller geometry control are comparatively costly and the flow control by throttling is not an energy efficient process. In this study an arrangement of metered dosing flow was developed using a typical low cost centrifugal pump using bypass flow technique. Using bypass flow control technique a wide range of metered dosing flows under a range of heads were attained using fixed pump geometry and drive speed. The bulk flow returning from the system into the main tank ensures better mixing which may eliminate the need of separate agitators. Comparative performance study was made between the bypass flow control arrangement of centrifugal pump and a diaphragm type dosing pump. Similar heads and flow rates were attainable using the bypass control system compared to the diaphragm dosing pump, but using relatively more energy. Geometrical optimization of the centrifugal pump impeller was further carried out to make the bypass flow arrangement more energy efficient. Although both the systems run at low overall efficiencies but the capital cost could be reduced by about 87% compared to the dosing pump. The savings in capital investment and lower maintenance cost very significantly exceeds the relatively higher energy cost of the bypass system. This technique can be used as a cost effective solution for

  8. 40 CFR 1065.640 - Flow meter calibration calculations.

    Science.gov (United States)

    2010-07-01

    ... temperature of the flow rate. R = molar gas constant. M mix = molar mass of the flow rate. Example 1: V stdref... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.640 Flow meter....314472 J/(mol·K) ER08OC08.101 n ref = 19.619 mol/s Example 2: m ref = 17.2683 kg/min = 287.805 g/s M mix...

  9. Accidental Cutaneous Burns Secondary to Salbutamol Metered Dose Inhaler

    Directory of Open Access Journals (Sweden)

    Ashutosh Kale

    2010-01-01

    Full Text Available We report a case of accidental cutaneous burns caused by salbutamol metered dose inhaler. A 9-year-old boy underwent dental extraction at a children's hospital and was incidentally noted to have burn injuries on dorsum of both hands. On questioning, the boy revealed that a few days ago his 14-year-old brother, who is an asthmatic, playfully sprayed his salbutamol metered dose inhaler on the back of both his hands with the inhaler's mouth piece being in direct contact with the patient's skin. On examination, there was a rectangular area of erythema with superficial peeling on the dorsum of both hands, the dimensions of which exactly matched those of the inhaler's mouthpiece. It is possible that the injury could have been a chemical burn from the pharmaceutical/preservative/propellant aerosol or due to the physical effect of severe cooling of the skin or mechanical abrasive effect of the aerosol blasts or a combination of some or all the above mechanisms. This case highlights the importance of informing children and parents of the potentially hazardous consequences of misusing a metered dose inhaler.

  10. Stress-meter alignment in French vocal music.

    Science.gov (United States)

    Temperley, Nicholas; Temperley, David

    2013-07-01

    Previous research has shown disagreement regarding the nature of stress in French. Some have maintained that French has lexical stress on the final syllable of each word; others have argued that French has no lexical stress, only phrasal stress. A possible source of evidence on this issue is vocal music. In languages with lexical stress, such as English, it is well known that stressed syllables tend to occur at "strong" positions in the musical meter (some evidence will be presented supporting this view). A corpus analysis was performed to investigate the degree of stress-meter alignment in French songs. The analysis showed that (excluding syllables at the ends of lines) the final syllables of polysyllabic words tend to occur at stronger metrical positions than non-final syllables of those words; it also showed that monosyllabic content words tend to occur at stronger positions than monosyllabic function words. While conflicts between stress and meter are much more common in French than in English vocal music, these results suggest that French poets and composers recognized distinctions of stress between syllables of polysyllabic words and between monosyllabic content and function words.

  11. Comprehensive Flow Meter for All Materials. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-15

    The electromagnetic flowmeter is obstructionless and insensitive to the metered stuff's constitutive properties. For low zero-point drift, EM flowmeters employ a low frequency alternating induction, usually with square waveshape. With conventional signal conditioning, high frequency induction leads to excessive zero-point drift for the instrument. The conventional instrument is usable with electrically conductive fluids, where there is no triboelectric noise. Nonconductive fluids have substantial triboelectric noise, with spectral density experimentally measured to be f{sup {minus}2.6}. Here we use an electromagnet and signal conditioner that allows high frequency induction, where the noise is low, but eliminates the heretofore excessive drift--such that the EM flowmeter can be used to meter any stuff, whether conductive or insulating, that can be pumped, blown or extruded through a pipe. Designs and test hardware are shown. An injury occurred, with slow recovery: the principal investigator could not do all the flow test stand work desired. As an option, the flow testing has been simulated on a computer. Using characteristics of transformer oil as the metered fluid, the new signal conditioner has produced: (1) signal/noise/drift behavior experienced in prior published work, and (2) signal--without noise and drift--with performance of today's commercial EM flowmeters.

  12. Miniature, high efficiency transducers for use in ultrasonic flow meters

    Science.gov (United States)

    Saikia, Meghna

    This thesis is concerned with the development of a new type of miniature, high efficiency transducer for use in ultrasonic flow meters. The proposed transducer consists of a thin plate of a suitable piezoelectric material on which an inter-digital transducer is fabricated for the generation and detection of plate acoustic waves. When immersed in a fluid medium, this device can convert energy from plate acoustic waves (PAWs) into bulk acoustic waves (BAWs) and vice versa. It is shown that this mode coupling principle can be used to realize efficient transducers for use in ultrasonic flow meters. This transducer can be mounted flush with the walls of the pipe through which fluid is flowing, resulting in minimal disturbance of fluid flow. A prototype flow cell using these transducers has been designed and fabricated. The characteristics of this device have been measured over water flow rates varying from 0 to 7.5 liters per minute and found to be in good agreement with theory. Another attractive property of the new transducers is that they can be used to realize remotely read, passive, wireless flow meters. Details of methods that can be used to develop this wireless capability are described. The research carried out in this thesis has applications in several other areas such as ultrasonic nondestructive evaluation (NDE), noncontact or air coupled ultrasonics, and for developing wireless capability in a variety of other acoustic wave sensors.

  13. Accidental cutaneous burns secondary to salbutamol metered dose inhaler.

    Science.gov (United States)

    Kale, Ashutosh; Shackley, Fiona

    2010-01-01

    We report a case of accidental cutaneous burns caused by salbutamol metered dose inhaler. A 9-year-old boy underwent dental extraction at a children's hospital and was incidentally noted to have burn injuries on dorsum of both hands. On questioning, the boy revealed that a few days ago his 14-year-old brother, who is an asthmatic, playfully sprayed his salbutamol metered dose inhaler on the back of both his hands with the inhaler's mouth piece being in direct contact with the patient's skin. On examination, there was a rectangular area of erythema with superficial peeling on the dorsum of both hands, the dimensions of which exactly matched those of the inhaler's mouthpiece. It is possible that the injury could have been a chemical burn from the pharmaceutical/preservative/propellant aerosol or due to the physical effect of severe cooling of the skin or mechanical abrasive effect of the aerosol blasts or a combination of some or all the above mechanisms. This case highlights the importance of informing children and parents of the potentially hazardous consequences of misusing a metered dose inhaler.

  14. Unlocking the potential for efficiency and demand response throughadvanced metering

    Energy Technology Data Exchange (ETDEWEB)

    Levy, Roger; Herter, Karen; Wilson, John

    2004-06-30

    Reliance on the standard cumulative kilowatt-hour meter substantially compromises energy efficiency and demand response programs. Without advanced metering, utilities cannot support time-differentiated rates or collect the detailed customer usage information necessary to (1)educate the customer to the economic value of efficiency and demand response options, or (2) distribute load management incentives proportional to customer contribution. These deficiencies prevent the customer feedback mechanisms that would otherwise encourage economically sound demand-side investments and behaviors. Thus, the inability to collect or properly price electricity usage handicaps the success of almost all efficiency and demand response options. Historically, implementation of the advanced metering infrastructure (AMI) necessary for the successful efficiency and demand response programs has been prevented by inadequate cost-benefit analyses. A recent California effort has produced an expanded cost-effectiveness methodology for AMI that introduces previously excluded benefits. In addition to utility-centric costs and benefits, the new model includes qualitative and quantitative costs and benefits that accrue to both customers and society.

  15. Broadband PLC for Clustered Advanced Metering Infrastructure (AMI Architecture

    Directory of Open Access Journals (Sweden)

    Augustine Ikpehai

    2016-07-01

    Full Text Available Advanced metering infrastructure (AMI subsystems monitor and control energy distribution through exchange of information between smart meters and utility networks. A key challenge is how to select a cost-effective communication system without compromising the performance of the applications. Current communication technologies were developed for conventional data networks with different requirements. It is therefore necessary to investigate how much of existing communication technologies can be retrofitted into the new energy infrastructure to cost-effectively deliver acceptable level of service. This paper investigates broadband power line communications (BPLC as a backhaul solution in AMI. By applying the disparate traffic characteristics of selected AMI applications, the network performance is evaluated. This study also examines the communication network response to changes in application configurations in terms of packet sizes. In each case, the network is stress-tested and performance is assessed against acceptable thresholds documented in the literature. Results show that, like every other communication technology, BPLC has certain limitations; however, with some modifications in the network topology, it indeed can fulfill most AMI traffic requirements for flexible and time-bounded applications. These opportunities, if tapped, can significantly improve fiscal and operational efficiencies in AMI services. Simulation results also reveal that BPLC as a backhaul can support flat and clustered AMI structures with cluster size ranging from 1 to 150 smart meters.

  16. The smart meter and a smarter consumer: quantifying the benefits of smart meter implementation in the United States

    Directory of Open Access Journals (Sweden)

    Cook Brendan

    2012-04-01

    Full Text Available Abstract The electric grid in the United States has been suffering from underinvestment for years, and now faces pressing challenges from rising demand and deteriorating infrastructure. High congestion levels in transmission lines are greatly reducing the efficiency of electricity generation and distribution. In this paper, we assess the faults of the current electric grid and quantify the costs of maintaining the current system into the future. While the proposed “smart grid” contains many proposals to upgrade the ailing infrastructure of the electric grid, we argue that smart meter installation in each U.S. household will offer a significant reduction in peak demand on the current system. A smart meter is a device which monitors a household’s electricity consumption in real-time, and has the ability to display real-time pricing in each household. We conclude that these devices will provide short-term and long-term benefits to utilities and consumers. The smart meter will enable utilities to closely monitor electricity consumption in real-time, while also allowing households to adjust electricity consumption in response to real-time price adjustments.

  17. Voltage Harmonics Monitoring in a Microgrid Based on Advanced Metering Infrastructure (AMI)

    DEFF Research Database (Denmark)

    Firoozabadi, Mehdi Savaghebi; Guan, Yajuan; Quintero, Juan Carlos Vasquez

    2015-01-01

    Smart meters are the main part of Advanced Metering Infrastructure (AMI) and are usually able to provide detailed information on customers’ energy consumptions, voltage variations and interruptions. In addition, these meters are potentially able to provide more information about power quality (PQ......) disturbances. This paper will address the monitoring of voltage harmonics utilizing the features of smart meters and AMI system. To do this, the first step is to select proper indices to quantify the distortion. An important point which should be considered in this regard is the limited processing power...... of smart meters in comparison with PQ Analyzers (PQAs). Furthermore, the indices are categorized as site and system indices. The site indices measure the distortion at one metering section while the system indices provide a PQ view in an area encompassing multiple meters. In addition, the smart metering...

  18. Smart Metering in public utilities at Celle; In Celle spielt die (Zukunfts-) Musik

    Energy Technology Data Exchange (ETDEWEB)

    Tiede, Ingo; Gottschling, Florian; Luckhardt, Sina [EVB Energie AG, Velbert (Germany)

    2008-10-15

    Public utilities at Celle have start-up a pilot project to introduce Smart Metering. Presented is the system Meterus of EVB Energie AG by which meter data of power meters can be registered automatically during short time intervals and transmitted via the power grid. It is possible to integrate four meters in the system by the RF system ''M-bus RF receiver E''. (GL)

  19. Status of Net Metering: Assessing the Potential to Reach Program Caps

    Energy Technology Data Exchange (ETDEWEB)

    Heeter, J.; Gelman, R.; Bird, L.

    2014-09-01

    Several states are addressing the issue of net metering program caps, which limit the total amount of net metered generating capacity that can be installed in a state or utility service territory. In this analysis, we examine net metering caps to gain perspective on how long net metering will be available in various jurisdictions under current policies. We also surveyed state practices and experience to understand important policy design considerations.

  20. Comparative Analysis of Smart Meters Deployment Business Models on the Example of the Russian Federation Markets

    Directory of Open Access Journals (Sweden)

    Daminov Ildar

    2016-01-01

    Full Text Available This paper presents the comparison of smart meter deployment business models to determine the most suitable option providing smart meters deployment. Authors consider 3 main business model of companies: distribution grid company, energy supplier (energosbyt and metering company. The goal of the article is to compare the business models of power companies from massive smart metering roll out in power system of Russian Federation.

  1. Portable refrigerant charge meter and method for determining the actual refrigerant charge in HVAC systems

    Science.gov (United States)

    Gao, Zhiming; Abdelaziz, Omar; LaClair, Tim L.

    2017-08-08

    A refrigerant charge meter and a method for determining the actual refrigerant charge in HVAC systems are described. The meter includes means for determining an optimum refrigerant charge from system subcooling and system component parameters. The meter also includes means for determining the ratio of the actual refrigerant charge to the optimum refrigerant charge. Finally, the meter includes means for determining the actual refrigerant charge from the optimum refrigerant charge and the ratio of the actual refrigerant charge to the optimum refrigerant charge.

  2. 49 CFR 192.355 - Customer meters and regulators: Protection from damage.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Customer meters and regulators: Protection from... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Customer Meters, Service Regulators, and Service Lines § 192.355 Customer meters and regulators: Protection from...

  3. Downhole multiphase metering in wells by means of soft-sensing

    NARCIS (Netherlands)

    Leskens, M.; Kruif, B. de; Belfroid, S.P.C.; Smeulers, J.P.M.; Gryzlov, A.

    2008-01-01

    Multiphase flow meters are indispensable tools for achieving optimal operation and control of wells as these meters deliver real-time information about their performance. For example, multiphase flow meters located downhole can improve the production of multilateral and multizone wells by timely

  4. Performance of Virtual Current Meters in Hydroelectric Turbine Intakes

    Energy Technology Data Exchange (ETDEWEB)

    Harding, Samuel F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States). Hydrology Group; Romero-Gomez, Pedro D. J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States). Hydrology Group; Richmond, Marshall C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States). Hydrology Group

    2016-04-30

    Standards provide recommendations for the best practices in the installation of current meters for measuring fluid flow in closed conduits. These include PTC-18 and IEC-41 . Both of these standards refer to the requirements of the ISO Standard 3354 for cases where the velocity distribution is assumed to be regular and the flow steady. Due to the nature of the short converging intakes of Kaplan hydroturbines, these assumptions may be invalid if current meters are intended to be used to characterize turbine flows. In this study, we examine a combination of measurement guidelines from both ISO standards by means of virtual current meters (VCM) set up over a simulated hydroturbine flow field. To this purpose, a computational fluid dynamics (CFD) model was developed to model the velocity field of a short converging intake of the Ice Harbor Dam on the Snake River, in the State of Washington. The detailed geometry and resulting wake of the submersible traveling screen (STS) at the first gate slot was of particular interest in the development of the CFD model using a detached eddy simulation (DES) turbulence solution. An array of virtual point velocity measurements were extracted from the resulting velocity field to simulate VCM at two virtual measurement (VM) locations at different distances downstream of the STS. The discharge through each bay was calculated from the VM using the graphical integration solution to the velocity-area method. This method of representing practical velocimetry techniques in a numerical flow field has been successfully used in a range of marine and conventional hydropower applications. A sensitivity analysis was performed to observe the effect of the VCM array resolution on the discharge error. The downstream VM section required 11–33% less VCM in the array than the upstream VM location to achieve a given discharge error. In general, more instruments were required to quantify the discharge at high levels of accuracy when the STS was

  5. Non-CFC metered dose inhalers: the patent landscape.

    Science.gov (United States)

    Bowman, P A; Greenleaf, D

    1999-09-10

    There have been many patent applications to the European Patent Office over the past decade involving the transition of pressurised metered dose inhalers from the CFCs to non-CFC propellants. In addition to those where formulations are changed, there are those relating to specific drugs or drug classes, processes of manufacture and modifications to the container/closure system. Many of these have been opposed, usually on the grounds of obviousness. However, due to the length of time for the opposition process and the fact that there are few non-CFC pressurised inhalers on the market yet, the complete picture of which patents are valid has yet to unfold.

  6. Attacks and their Defenses for Advanced Metering Infrastructure

    DEFF Research Database (Denmark)

    Lighari, Sheeraz Niaz; Hussain, Dil Muhammad Akbar; Bak-Jensen, Birgitte

    2014-01-01

    channels. AMI is also featuring to communicate control functions from utility to the smart meters. So, both the consumption data and control data needs to be securely transmitted to their ends. Any leak and tempering may produce the dire effects to both utility and consumers. Hence security of AMI...... is a very important concern to take real advantage of this technology. In this paper, first we analyze the security threats faced by AMI components and then propose the countermeasures to tackle them. The aim is to visualize the possible threats in the context of confidentiality, integrity and availability...

  7. Interfacing of high temperature Z-meter setup using python

    Science.gov (United States)

    Patel, Ashutosh; Sisodia, Shashank; Pandey, Sudhir K.

    2017-05-01

    In this work, we interface high temperature Z-meter setup to automize the whole measurement process. A program is built on open source programming language `Python' which convert the manual measurement process into fully automated process without any cost addition. Using this program, simultaneous measurement of Seebeck coefficient (α), thermal conductivity (κ) and electrical resistivity (ρ), are performed and using all three, figure-of-merit (ZT) is calculated. Developed program is verified by performing measurement over p-type Bi0.36Sb1.45Te3 sample and the data obtained are found to be in good agreement with the reported data.

  8. Laser Coherence Meter Based on Nanostructured Liquid Crystals

    Directory of Open Access Journals (Sweden)

    A. Anczykowska

    2013-01-01

    Full Text Available We present the method for coherence length measurement using coherence meter based on hybrid liquid crystal structures doped with gold nanoparticles. The results indicate that the method is able to determine the coherence length of coherent light sources with precision of 0.01 m at wavelength range from 200 to 800 nm for wide range of initial beam powers starting from 1 mW. Given the increasing use of laser technology in industry, military, or medicine, our research may open up a possible route for the development of improved techniques of coherent diagnostic light sources.

  9. The KFM, A Homemade Yet Accurate and Dependable Fallout Meter

    Energy Technology Data Exchange (ETDEWEB)

    Kearny, C.H.

    2001-11-20

    The KFM is a homemade fallout meter that can be made using only materials, tools, and skills found in millions of American homes. It is an accurate and dependable electroscope-capacitor. The KFM, in conjunction with its attached table and a watch, is designed for use as a rate meter. Its attached table relates observed differences in the separations of its two leaves (before and after exposures at the listed time intervals) to the dose rates during exposures of these time intervals. In this manner dose rates from 30 mR/hr up to 43 R/hr can be determined with an accuracy of {+-}25%. A KFM can be charged with any one of the three expedient electrostatic charging devices described. Due to the use of anhydrite (made by heating gypsum from wallboard) inside a KFM and the expedient ''dry-bucket'' in which it can be charged when the air is very humid, this instrument always can be charged and used to obtain accurate measurements of gamma radiation no matter how high the relative humidity. The heart of this report is the step-by-step illustrated instructions for making and using a KFM. These instructions have been improved after each successive field test. The majority of the untrained test families, adequately motivated by cash bonuses offered for success and guided only by these written instructions, have succeeded in making and using a KFM. NOTE: ''The KFM, A Homemade Yet Accurate and Dependable Fallout Meter'', was published by Oak Ridge National Laboratory report in1979. Some of the materials originally suggested for suspending the leaves of the Kearny Fallout Meter (KFM) are no longer available. Because of changes in the manufacturing process, other materials (e.g., sewing thread, unwaxed dental floss) may not have the insulating capability to work properly. Oak Ridge National Laboratory has not tested any of the suggestions provided in the preface of the report, but they have been used by other groups. When using these

  10. MSET modeling of Crystal River-3 venturi flow meters.

    Energy Technology Data Exchange (ETDEWEB)

    Bockhorst, F. K.; Gross, K. C.; Herzog, J. P.; Wegerich, S. W.

    1998-01-05

    The analysis of archived Crystal River-3 feedwater flow data reveals a slow and steady degradation of the flow meter measurements during the 1992/1993 operating cycle. MSET can reliably estimate the true flow rate and quantify the degree of departure between the indicated signal and the true flow rate with high accuracy. The MSET computed flow rate could, in principle, be used to provide an improved estimate of the reactor power and hence avoid the revenue loss associated with derating the reactor based on a faulty feedwater flow rate indication.

  11. Planning the 8-meter Chinese Giant Solar Telescope

    Science.gov (United States)

    Beckers, Jacques M.; Liu, Z.; Deng, Y.; Ji, H.

    2013-07-01

    The Chinese Giant Solar Telescope (CGST) will be a diffraction limited solar telescope optimized for the near-infrared (NIR) spectral region (0.8 - 2.5 microns). Its diffraction limit will be reached by the incorporation of Multi-Conjugate Adaptive Optics (MCAO) enhanced by image restoration techniques to achieve uniform (u.v) plane coverage over the angular spatial frequency region allowed by its 8-meter aperture. Thus it will complement the imaging capabilities of 4-meter telescopes being planned elsewhere which are optimized for the visible (VIS) spectral region (300 - 1000 nm) In the NIR spectral regions the CGST will have access to unique spectral features which will improve the diagnostics of the solar atmosphere. These include the CaII lines near 860 nm , the HeI lines near 1083 nm, the 1074 nm FeXIII coronal lines, the large Zeeman-split FeI line at 1548 nm, and (v) the H- continuum absorption minimum at 1.6 micron. Especially in sunspot umbrae the simultaneous observation of continua and lines across the NIR spectral range will cover a substantial depth range in the solar atmosphere. Of course the mid- and far- infrared regions are also available for unequalled high-angular resolution solar observations, for example, in the Hydrogen Bracket lines, CO molecular bands, and the MgI emission line at 12.3 microns. The CGST is a so-called ring telescope in which the light is captured by a 1 meter wide segmented ring or by a ring of 7 smaller off-axis aperture telescopes. The open central area of the telescope is large. The advantages of such a ring configuration is that (a) it covers all the spatial frequencies out to those corresponding to its outer diameter, (b) its circular symmetry makes it polarization neutral, (c) its large central hole helps thermal control, and (d) it provides ample space for the MCAO system and instrumentation in the Gregorian focus. Even though optimized for the NIR, we expect to use the CGST also at visible wavelengths in the so

  12. Cosmic magnetism in centimeter- and meter-wavelength radio astronomy

    Science.gov (United States)

    Akahori, Takuya; Nakanishi, Hiroyuki; Sofue, Yoshiaki; Fujita, Yutaka; Ichiki, Kiyotomo; Ideguchi, Shinsuke; Kameya, Osamu; Kudoh, Takahiro; Kudoh, Yuki; Machida, Mami; Miyashita, Yoshimitsu; Ohno, Hiroshi; Ozawa, Takeaki; Takahashi, Keitaro; Takizawa, Motokazu; Yamazaki, Dai G.

    2017-12-01

    The magnetic field is ubiquitous in the universe. Though it plays an essential role in various astrophysical phenomena, its real origin and evolution are poorly known. This article reviews the understanding of the latest research concerning magnetic fields in the interstellar medium, the Milky Way Galaxy, external galaxies, active galactic nuclei, clusters of galaxies, and the cosmic web. Particularly, the review is concentrated in the achievements that have been provided by centimeter- and meter-wavelength radio observations. The article also introduces various methods for analyzing linear polarization data, including synchrotron radiation, Faraday rotation, depolarization, and Faraday tomography.

  13. Smart Metering. Between technical challenge and societal acceptance - Interdisciplinary status quo; Smart Metering. Zwischen technischer Herausforderung und gesellschaftlicher Akzeptanz - Interdisziplinaerer Status Quo

    Energy Technology Data Exchange (ETDEWEB)

    Westermann, Dirk; Doering, Nicola; Bretschneider, Peter (eds.)

    2013-04-01

    The international research project RESIDENS (more efficient energy utilization by means of system technical integration of the private ultimate consumer) investigates the technology of smart metering that is the utilization of intelligent smart meters in private households. The interdisciplinary character of the RESIDENS project becomes visible by different sub-projects examining different formulations of a question from perspectives of different scientific disciplines: First of all, chapter 2 of the contribution under consideration follows up the question, what impact the media coverage on smart metering has on the perception of this technology in the population at large. Chapter 3 reports on the state of the art of the smart metering. Chapter 4 illustrates how a load control of private consumers can be performed by means of the smart meter technology. Chapter 5 reports on the impacts of the smart metering on the procurement of energy in the liberalised energy market. Chapter 6 investigates the smart metering from the customer's point of view. Concretely, the user-friendliness of an internet portal is evaluated by which the customers may follow up their consumption of electricity by means of an intelligent smart meter continuously. Chapter 7 illustrates legal aspects of smart metering from the perspective of the customer, electricity suppliers and distribution system operators. Chapter 8 presents the conception and implementation of an online gaming operation for the promotion of competency of private power customers: In line with this game, the participants may learn to handle smart metering and flexible electricity tariffs in an entertaining manner. Finally, chapter 9 reports on an expert interview in which the smart metering technology is evaluated by public utilities being involved in this project.

  14. Examining the effect of poems' content on meter in pre-Mogul Persian odes

    Directory of Open Access Journals (Sweden)

    Mohammad hossein Karami

    2016-12-01

    Only in some versifications and meters a distinction can be seen in terms of application, such as in present versifications and the main meters extracted from them that to some extent in happy and sad themes have different applications. Of course, also this distinction is not the result of conscious choice of meters, according to the content, but is due to different style and geographical tastes of meters selection among various poets and also a dominant literary tradition in each period. In this dominant literary tradition, in some periods due to social and cultural reasons, odes' dominant content was sad and/ or happy, indicating specific meters in typical poets' style.

  15. An objective comparison of commercially-available cavitation meters.

    Science.gov (United States)

    Sarno, Daniel; Hodnett, Mark; Wang, Lian; Zeqiri, Bajram

    2017-01-01

    With a number of cavitation meters on the market which claim to characterise fields in ultrasonic cleaning baths, this paper provides an objective comparison of a selection of these devices and establishes the extent to which their claims are met. The National Physical Laboratory's multi-frequency ultrasonic reference vessel provided the stable 21.06kHz field, above and below the inertial cavitation threshold, as a test bed for the sensor comparison. Measurements from these devices were evaluated in relation to the known acoustic pressure distribution in the cavitating vessel as a means of identifying the mode of operation of the sensors and to examine the particular indicator of cavitation activity which they deliver. Through the comparison with megahertz filtered acoustic signals generated by inertial cavitation, it was determined that the majority of the cavitation meters used in this study responded to acoustic pressure generated by the direct applied acoustic field and therefore tended to overestimate the occurrence of cavitation within the vessel, giving non-zero responses under conditions when there was known to be no inertial cavitation occurring with the reference vessel. This has implications for interpreting the data they provide in user applications. Copyright © 2016. Published by Elsevier B.V.

  16. Frequency Management for Electromagnetic Continuous Wave Conductivity Meters

    Directory of Open Access Journals (Sweden)

    Przemyslaw Mazurek

    2016-04-01

    Full Text Available Ground conductivity meters use electromagnetic fields for the mapping of geological variations, like the determination of water amount, depending on ground layers, which is important for the state analysis of embankments. The VLF band is contaminated by numerous natural and artificial electromagnetic interference signals. Prior to the determination of ground conductivity, the meter’s working frequency is not possible, due to the variable frequency of the interferences. Frequency management based on the analysis of the selected band using track-before-detect (TBD algorithms, which allows dynamical frequency changes of the conductivity of the meter transmitting part, is proposed in the paper. Naive maximum value search, spatio-temporal TBD (ST-TBD, Viterbi TBD and a new algorithm that uses combined ST-TBD and Viterbi TBD are compared. Monte Carlo tests are provided for the numerical analysis of the properties for a single interference signal in the considered band, and a new approach based on combined ST-TBD and Viterbi algorithms shows the best performance. The considered algorithms process spectrogram data for the selected band, so DFT (Discrete Fourier Transform could be applied for the computation of the spectrogram. Real–time properties, related to the latency, are discussed also, and it is shown that TBD algorithms are feasible for real applications.

  17. LLNL current meter array--concept and system description

    Energy Technology Data Exchange (ETDEWEB)

    Mantrom, D.D. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    A measurement capability using a horizontal array of 10 S4 current meters mounted on a stiff floating structure with 35 m aperture has been developed to support interpretation of radar imaging of surface effects associated with internal waves. This system has been fielded three times and most recently, has collected data alongside the sea-surface footprint of a land-fixed radar imaging ship-generated internal waves. The underlying need for this measurement capability is described. The specifications resulting from this need are presented and the engineering design and deployment procedures of the platform and systems that resulted are described The current meter data are multiplexed along with meteorological and system status data on board the floating platform and are telemetered to a shore station and on to a data acquisition system. The raw data are recorded, and are then processed to form space-time images of current and strain rate (a spatial derivative of the current field). Examples of raw and processed data associated with ship-generated internal waves are presented.

  18. Metering, settlement and export reward options for micro-generation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    This report presents the results of a study carried out as part of the Department of Trade and Industry's New and Renewable Energy Programme to evaluate the costs and benefits of various metering, settlement and export reward opportunities for both renewable and non-renewable forms of microgeneration based on existing projections to 2020. The technologies studied included single and three-phase applications of: solar photovoltaic (rated at 1 kW per installation); small-scale wind generation (rated at 1 kW per installation); micro-CHP (combined heat and power) (rated at 1.1 kW per installation); and micro-hydropower (rated at 3.7 and 6.4 kW per installation). The report outlines a number of different options for metering, settlement and export rewards, and describes the development of an economic model to quantify their costs and benefits. This model is then used to predict the future costs and benefits of the various options. The potential value of the options to the UK economy and any environmental benefits are discussed and a commentary on possible barriers to implementation is provided.

  19. Security Challenges in Smart-Grid Metering and Control Systems

    Directory of Open Access Journals (Sweden)

    Xinxin Fan

    2013-07-01

    Full Text Available The smart grid is a next-generation power system that is increasingly attracting the attention of government, industry, and academia. It is an upgraded electricity network that depends on two-way digital communications between supplier and consumer that in turn give support to intelligent metering and monitoring systems. Considering that energy utilities play an increasingly important role in our daily life, smart-grid technology introduces new security challenges that must be addressed. Deploying a smart grid without adequate security might result in serious consequences such as grid instability, utility fraud, and loss of user information and energy-consumption data. Due to the heterogeneous communication architecture of smart grids, it is quite a challenge to design sophisticated and robust security mechanisms that can be easily deployed to protect communications among different layers of the smart grid-infrastructure. In this article, we focus on the communication-security aspect of a smart-grid metering and control system from the perspective of cryptographic techniques, and we discuss different mechanisms to enhance cybersecurity of the emerging smart grid. We aim to provide a comprehensive vulnerability analysis as well as novel insights on the cybersecurity of a smart grid.

  20. Establishing traceability of scatterometry to the SI meter

    Directory of Open Access Journals (Sweden)

    Nielsen L.

    2010-06-01

    Full Text Available We present an uncertainty estimate for numerical reconstruction of grating profiles using scatterometry and show how traceability to the SI meter may be obtained using measurement standards. By describing the propagation of light through non-ideal optical components and the light interaction with a nonideal sample under test, we establish a model function for the detected power that contains all the significant error sources in the setup. After having assigned typical uncertainties to the parameters of the optical elements, the model function is used to investigate the effect of sample misalignment for varying angle of incidents. This study shows that normal incident is preferable with respect to uncertainties. We continue by considering measurements performed with non-ideal settings and investigate how these erroneously settings affect the scatterometry parameters of the sample, such as height, fill factor and wall angles found from a least squares match between measured and calculated diffraction efficiencies. The input to this least squares method is 1 best estimates and the associated covariance matrix of all measured quantities, including influence quantities, and 2 a measurement model describing all known physical relations between the measured quantities and the scatterometry parameters. The output includes best estimates and the associated covariance matrix of the scatterometry parameters. Having the model function for the measurement, the uncertainties of all relevant quantities and a robust least squares algorithm, we can establish a traceability chain to the SI meter.

  1. Modal Test of Six-Meter Hypersonic Inflatable Aerodynamic Decelerator

    Science.gov (United States)

    Abraham, Nijo; Buehrle, Ralph; Templeton, Justin; Lindell, Mike; Hancock, Sean M.

    2014-01-01

    A modal test was performed on the six-meter Hypersonic Inflatable Aerodynamic Decelerator (HIAD) test article to gain a firm understanding of the dynamic characteristics of the unloaded structure within the low frequency range. The tests involved various configurations of the HIAD to understand the influence of the tri-torus, the varying pressure within the toroids and the influence of straps. The primary test was conducted utilizing an eletrodynamic shaker and the results were verified using a step relaxation technique. The analysis results show an increase in the structure's stiffness with respect to increasing pressure. The results also show the rise of coupled modes with the tri-torus configurations. During the testing activity, the attached straps exhibited a behavior that is similar to that described as fuzzy structures in the literature. Therefore extensive tests were also performed by utilizing foam to mitigate these effects as well as understand the modal parameters of these fuzzy sub structures. Results are being utilized to update the finite element model of the six-meter HIAD and to gain a better understanding of the modeling of complex inflatable structures.

  2. Research on data collection key technology of smart electric energy meters

    Science.gov (United States)

    Chen, Xiangqun; Huang, Rui; Shen, Liman; Chen, Hao; Xiong, Dezhi; Xiao, Xiangqi; Mouhailiu; Renheng, Xu

    2018-02-01

    In recent years, smart electric energy meters are demand at 70 million to 90 million with the strong smart grid construction every year in China. However, there are some issues in smart electric energy meters data collection such as the interference of environment, low collection efficiency and inability to work when the power is off. In order to solve these issues above, it uses the RFID communication technology to collect the numbers and electric energy information of smart electric energy meters on the basis of the existing smart electric energy meters, and the related data collection communication experiments were made. The experimental result shows that the electric information and other data batch collection of RFID smart electric energy meters are realized in power and power off. It improves the efficiency and the overall success rate is 99.2% within 2 meters. It provides a new method for smart electric energy meters data collection.

  3. AGFW interlaboratory test for validation of test authorities for heat meters. Volume flow metering; AGFW-Ringversuch fuer Pruefstellen fuer Waerme-Messgeraete. Volumenstrommessung

    Energy Technology Data Exchange (ETDEWEB)

    Leitgen, Guenter [WSG Waermezaehler Service GmbH, Essen (Germany); Espig, Frank [AGFW - Der Energieeffizienzverband fuer Waerme, Kaelte und KWK e. V., Frankfurt am Main (Germany)

    2010-01-15

    For regular validation of authorized test institutions for heat meters in Germany and Austria, the AGFW carried out an interlaboratory test using a transfer normal, in which 25 test authorities participated. Volume flow metering was the first stage; the authors present the measuring programme and discuss the results. (orig.)

  4. Reciprocity and its utilization in ultrasonic flow meters

    Energy Technology Data Exchange (ETDEWEB)

    Lunde, Per; Vestrheim, Magne; Boe, Reidar; Smoergrav, Skule; Abrahamsen, Atle K.

    2005-07-01

    In ultrasonic transit time flow meters for gas and liquid (USMs), the flow direction, the flow velocity and the sound velocity are estimated from the measured up- and downstream transit times. At no-flow conditions, the up- and downstream transit times of such meters should ideally be the same, or the difference should be negligible. This may not be the case unless special precautions are made. In order to reduce the possibility of the meter to detect a false flow at no-flow conditions, USMs are typically ''dry calibrated'' before being installed in the field. ''Dry calibration'' (which may be made in different ways), in general involves measurement of (a) the time delays due to electronics, cables and transducers, (b) the so called ''{delta}t-correction'' (for each acoustic path, also denoted ''zero flow offset factor''), and (c) geometrical parameters. Various {delta}t-correction approaches may be used by different manufacturers, but these are basically similar and have the same purpose: to reduce the false flow detection and improve the accuracy at low and no-flow conditions (''zero flow adjustment''), without significantly affecting the accuracy at the high velocity measurements. The AGA-9 report and the API MPMS Ch. 5.8 standard both prescribe need for ''zero flow verification test (zero test)'' or ''zeroing the meter'', for gas and liquid USMs, respectively. Advances in USM technology based on the electro acoustic reciprocity principle have provided methods for reduction or even neglect ion of the need for ''{delta} t-correction'' of USMs. That means, if the USM measurement system is reciprocal, and operated in a ''sufficiently reciprocal'' way, the ''{delta}t-correction'' may be negligibly small over the operational range of pressure and temperature, and

  5. PELATIHAN LARI SAMBUNG BACK TO BACK 20 METER ENAM REPETISI EMPAT SET DAN LARI SAMBUNG BACK TO BACK 30 METER EMPAT REPETISI EMPAT SET MENINGKATKAN KECEPATAN LARI 80 METER SISWA PUTRA SMP DHARMA PRAJA BADUNG

    Directory of Open Access Journals (Sweden)

    Gimbar Adiputra

    2015-08-01

    Full Text Available Type of 80 meters ran is one of the numbers on athletics competed in early age of child. In early age, the physical condition and mind can still be developed continuously and systematically. The exercise in early age should be an element of play and competition, thus this exercise is attempted to develop the speed by two types of exercise: back to back relay run of 20 meters six reps four sets and back to back relay run of 30 meters four reps four sets. The aim of research is to know the increasing of 80 meters speed of run. The exercise was conducted for six weeks with a frequency of three times a week with the aim to increasing the speed. The numbered of sample was 24 people selected randomly from junior high school students of Dharma Praja Badung that meets the requirements of inclusion and exclusion. The numbered of each group consists of twelve people. Each group was given a different treatment i.e. group I was treated by back to back relay run of 20 meters six reps and four sets and group II treated by back to back relay run of 30 meters four reps four sets. Data derived from the duration time of 80 meters ran before and after exercise, with t paired test to determine the difference average speed of duration time before and after exercise in each group. The t Unpaired test for the difference average of increased speed between two groups with significance limit of 0.05. The differences of speed in 80 meters ran after exercise in both groups showed significant differences, i.e. p = 0.000 (p <0.05. The average of duration time of 80 meters ran in Group I before exercise was 13.51 sec and after exercise was 12.31 sec by difference of 1.16 seconds show significant differences, while Group 2 the average of duration time in 80 meters ran before exercise and after exercise was 13.66 and after 12, 67 by a difference of 0.98 seconds showed significant differences due to differences in distance and number of repetitions between Group I and Group II

  6. A side-by-side test of four land gravity meters

    Energy Technology Data Exchange (ETDEWEB)

    Chapin, D.A.; Crawford, M.F. [ARCO Exploration and Production Technology, Plano, TX (United States); Baumeister, M. [Photo Gravity Corp., Houston, TX (United States)

    1999-05-01

    Four different land gravity meters were run side by side on a test range in eastern Texas. This test range was designed to duplicate typical field survey conditions encountered in gravity measurements on 3-D land seismic surveys. A profile of 270 stations was acquired with a station spacing of 33.5 m (110 ft). The four meters were Scintrex CG-3, Sodin, LaCoste and Romberg (L and R) G-meter, and Edcon/L and R Super-G meter. The purpose of this study was to determine which of the four meters had the best balance of accuracy, convenience, and speed of measurement for these specialized surveys. All four meters had their limitations, and no single meter was greatly superior to the others. The CG-3 was awkward in leveling, had a large (368 {mu}Gal per day) drift rate, and had some quirks in its user interface. The Sodin meter had problems controlling its temperature and, at one point, had a very high 935 {mu}Gal per day drift rate. It had the poorest accuracy of the four. The G-meter lacked a convenient digital user interface; thus, it was susceptible to operator blunder in misreading or recording the data. The Super-G meter also had some problems in its user interface, had only a 6-mGal range without a range change, and was the heaviest of the field instruments. An unbiased statistical estimator was developed to analyze the data. The technique determined the best three meters at each station. Both the G-meter and the Super-G meter produced the most accurate data. They had an average absolute deviation from the mean of 209 and 23 {mu}Gal, respectively. In comparison, the two quartz meters--the CG-3 and the Sodin--had an average absolute deviation from the mean of 31 and 46 {mu}Gal, respectively. The authors would like to see the manufacturers improve (or add, in the case of the G-meter and the Sodin) their digital interfaces. Additionally, they would like to see upgrades in the thermal control systems in all the meters. The single largest amount of station time was

  7. A literature review on optimum meter placement algorithms for distribution state estimation

    Energy Technology Data Exchange (ETDEWEB)

    Ramesh, L. [Jadavpur Univ., Kolkotta (India); Chowdhury, S.P.; Chowdhury, S.; Gaunt, C.T. [Cape Town Univ., (South Africa)

    2009-07-01

    A literature review of meter placement for the monitoring of power distribution systems was presented. The aim of the study was to compare different algorithms used for solving optimum meter placement. The percentage of algorithms used and the number of studies conducted to determine optimal placement were plotted on graphs in order to determine the performance accuracy for different meter placement algorithms. Measurements used for state estimation were collected through SCADA systems. The data requirements for real time monitoring and the control of distribution systems were identified using a rule-based meter placement method. Rules included placing meters at all switch and fuse locations that require monitoring; placing additional meters along feeder line sections; placing meters on open tie switches that are used for feeder switching. The genetic algorithm technique was used to consider both the investment costs and real-time monitoring capability of the meters. It was concluded that the branch-current-based 3-phase state estimation algorithm can be used to determine optimal meter placements for distribution systems. The method allowed for the placement of fewer meters. 24 refs., 1 tab., 3 figs.

  8. Commissioning of the LINAC4 Ion Source Transverse Emittance Meter

    CERN Document Server

    Bravin, E; Dutriat, C; Lokhovitsky, A; Raich, U; Roncarolo, F; Scrivens, R; Zorin, E

    2010-01-01

    LINAC4 is the first step in the upgrade of the injector chain for the LHC, and will accelerate H- ions from 45 keV to 160 MeV. Currently the ion source is installed in a test setup and its commissioning started at the end of 2009. A slit-grid system is used to measure the transverse emittance of the beam at the exit of the source. The results of the measurements have been compared with analytical and numerical predictions of the performance of the emittance meter, addressing the system resolution, accuracy and sensitivity. The outcome of this analysis has been used to improve the design of a new slit-grid system foreseen for the commissioning of LINAC 4 at higher energy locations.

  9. A Novel Parameter for Ramp Metering and Evaluation

    Science.gov (United States)

    Li, Jian; Jia, Yuanhua; Zhang, Yong; Chen, Feng; Ao, Guchang

    Real and scientific traffic flow parameter are the basis to make efficient traffic control strategy and establish control function and this will leads to an appropriate and impartial reflection to efficiency and equity of control property. Intelligent control is a new development where the control problem is to find the combination of control measures that result in the best road performance and control effectiveness. The problems of intelligent metering evaluation for local ramp are considered. In this paper, a novel ramp queuing parameter-the reduplicated waiting time was posed using the queuing theory. With in-situ traffic flow data, comparison between the novel and previous parameters are made to clarify the advantages of the novel parameter.

  10. Metered Channel Service - A high speed DAMA SCPC data service

    Science.gov (United States)

    Skjei, Sidney M.; Talberth, Katherine T.

    1992-03-01

    The design, development, and implementation of a new demand assigned multiple access (DAMA) data service, Metered Channel Service (MCS), are described. This service allows 'pay as you go' data at multiple data rates, up to 2.048 Mbps, with broadcast or duplex connectivity. Duplex circuits may be asymmetrical, with (for example) a 1.544 Mbps in one direction answered by a 56 Kbps return link. The service has been in operation in the United States for over three years, using very small aperture terminals (VSATs) and a terrestrial signaling channel. A new satellite signaling channel (SSC) is currently in beta test which will eliminate the need for terrestrial call setups. The primary MCS user applications are also discussed.

  11. Open-channel integrating-type flow meter

    Science.gov (United States)

    Koopman, K.C.

    1971-01-01

    A relatively inexpensive meter for measuring cumulative flow in open channels with a rated control,. called a "totalizer", was developed. It translates the nonlinear function of gage height to flow by use of a cam and a float. A variable resistance element in an electronic circuit is controlled by the float so that the electron flow in the circuit corresponds to the flow of water. The flow of electricity causes electroplating of an electrode with silver. The amount of silver deposited is proportionate to the flow of water. The total flow of water is determined by removing the silver from the electrode at a fixed rate with ·an electronic device and recording the time for removal with a counter. The circuit is designed so that the ,resultant reading on the counter is in acre-feet of water.

  12. Development of an intelligent adapter for metered dose inhalers

    Directory of Open Access Journals (Sweden)

    Zhang Mingrong

    2016-01-01

    Full Text Available To better coordinate the interaction of inhalation and aerosol release, an intelligent adapter (IA was developed for metered dose inhalers (MDIs. The adapter included three main units: a signal acquisition device, a micro-control-unit (MCU, and an actuation mechanism. To fully study the effectiveness of the intelligent adapter, an inhalation simulation experiment was done, and two bands of MDI were used for the experiment. The results indicated that, when inhalation, the intelligent adapter can press down the MDI automatically; moreover, this intelligent adapter could achieve an aerosol-release time Tr of 0.4 s for MDI A and 0.60 s for MDI B, which compares very well with the existing pure mechanical systems at 0.8 s and 1.0 s.

  13. Analysis of a scaling rate meter for geothermal systems

    Energy Technology Data Exchange (ETDEWEB)

    Kreid, D.K.

    1980-03-01

    A research project was conducted to investigate an experimental technique for measuring the rate of formation of mineral scale and corrosion in geothermal systems. A literature review was performed first to identify and evaluate available techniques for measuring scale in heat transfer equipment. As a result of these evaluations, a conceptual design was proposed for a geothermal Scaling Rate Meter (SRM) that would combine features of certain techniques used (or proposed for use) in other applications. An analysis was performed to predict the steady-state performance and expected experimental uncertainty of the proposed SRM. Sample computations were then performed to illustrate the system performance for conditions typical of a geothermal scaling application. Based on these results, recommendations are made regarding prototype SRM construction and testing.

  14. A low-power battery ampere-hour meter

    Science.gov (United States)

    Tripp, John S.; Schott, Timothy D.

    A digital device has been developed to meter the current drain of a battery in ampere hours. The device consists of a voltage controlled oscillator (VCO), a frequency divider, an accumulator, and a liquid crystal display. A voltage proportional to load current is converted into a clock signal whose pulse rate is scaled by the frequency divider to the desired engineering units. Final output pulses are counted and displayed. The use of MOSFET and CMOS integrated circuits allows continuous battery-powered operation over a 3-month time period to an accuracy of +/- 2 percent. The instrument will find application where accurate monitoring of battery charge/discharge status is required over long time intervals.

  15. An accurate and portable solid state neutron rem meter

    Energy Technology Data Exchange (ETDEWEB)

    Oakes, T.M. [Nuclear Science and Engineering Institute, University of Missouri, Columbia, MO (United States); Bellinger, S.L. [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS (United States); Miller, W.H. [Nuclear Science and Engineering Institute, University of Missouri, Columbia, MO (United States); Missouri University Research Reactor, Columbia, MO (United States); Myers, E.R. [Department of Physics, University of Missouri, Kansas City, MO (United States); Fronk, R.G.; Cooper, B.W [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS (United States); Sobering, T.J. [Electronics Design Laboratory, Kansas State University, KS (United States); Scott, P.R. [Department of Physics, University of Missouri, Kansas City, MO (United States); Ugorowski, P.; McGregor, D.S; Shultis, J.K. [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS (United States); Caruso, A.N., E-mail: carusoan@umkc.edu [Department of Physics, University of Missouri, Kansas City, MO (United States)

    2013-08-11

    Accurately resolving the ambient neutron dose equivalent spanning the thermal to 15 MeV energy range with a single configuration and lightweight instrument is desirable. This paper presents the design of a portable, high intrinsic efficiency, and accurate neutron rem meter whose energy-dependent response is electronically adjusted to a chosen neutron dose equivalent standard. The instrument may be classified as a moderating type neutron spectrometer, based on an adaptation to the classical Bonner sphere and position sensitive long counter, which, simultaneously counts thermalized neutrons by high thermal efficiency solid state neutron detectors. The use of multiple detectors and moderator arranged along an axis of symmetry (e.g., long axis of a cylinder) with known neutron-slowing properties allows for the construction of a linear combination of responses that approximate the ambient neutron dose equivalent. Variations on the detector configuration are investigated via Monte Carlo N-Particle simulations to minimize the total instrument mass while maintaining acceptable response accuracy—a dose error less than 15% for bare {sup 252}Cf, bare AmBe, an epi-thermal and mixed monoenergetic sources is found at less than 4.5 kg moderator mass in all studied cases. A comparison of the energy dependent dose equivalent response and resultant energy dependent dose equivalent error of the present dosimeter to commercially-available portable rem meters and the prior art are presented. Finally, the present design is assessed by comparison of the simulated output resulting from applications of several known neutron sources and dose rates.

  16. Advances in metered dose inhaler technology: hardware development.

    Science.gov (United States)

    Stein, Stephen W; Sheth, Poonam; Hodson, P David; Myrdal, Paul B

    2014-04-01

    Pressurized metered dose inhalers (MDIs) were first introduced in the 1950s and they are currently widely prescribed as portable systems to treat pulmonary conditions. MDIs consist of a formulation containing dissolved or suspended drug and hardware needed to contain the formulation and enable efficient and consistent dose delivery to the patient. The device hardware includes a canister that is appropriately sized to contain sufficient formulation for the required number of doses, a metering valve capable of delivering a consistent amount of drug with each dose delivered, an actuator mouthpiece that atomizes the formulation and serves as a conduit to deliver the aerosol to the patient, and often an indicating mechanism that provides information to the patient on the number of doses remaining. This review focuses on the current state-of-the-art of MDI hardware and includes discussion of enhancements made to the device's core subsystems. In addition, technologies that aid the correct use of MDIs will be discussed. These include spacers, valved holding chambers, and breath-actuated devices. Many of the improvements discussed in this article increase the ability of MDI systems to meet regulatory specifications. Innovations that enhance the functionality of MDIs continue to be balanced by the fact that a key advantage of MDI systems is their low cost per dose. The expansion of the health care market in developing countries and the increased focus on health care costs in many developed countries will ensure that MDIs remain a cost-effective crucial delivery system for treating pulmonary conditions for many years to come.

  17. The Research on Metrological Characteristics of House Water Meters during Transitional Flow Regimes

    Directory of Open Access Journals (Sweden)

    Inga Briliūtė

    2011-04-01

    Full Text Available The purpose of this research is to find the influence of transitional flow regimes on inlet water meters. Four construction types of mechanical inlet water meters (each capacity Q = 10 m3/h were investigated. The biggest additional volume 0,12–0,26% when Q = 0,2…2 m3/h shows single-jet vane wheel meter. This additional volume is less 0,06–0,13% for the multi-jet concentric water meter. The minimum influence of transitional flow regimes was for turbine water meters till 0,1% for all flow range. The volumetric meters are not sensitive for this effect.Article in Lithuanian

  18. What Can Wireless Cellular Technologies Do about the Upcoming Smart Metering Traffic?

    DEFF Research Database (Denmark)

    Nielsen, Jimmy Jessen; Madueño, Germán Corrales; Pratas, Nuno

    2015-01-01

    The introduction of smart electricity meters with cellular radio interface puts an additional load on the wireless cellular networks. Currently, these meters are designed for low duty cycle billing and occasional system check, which generates a low-rate sporadic traffic. As the number...... and higher rates per device. In this paper, we characterize the current traffic generated by smart electricity meters and supplement it with the potential traffic requirements brought by introducing enhanced Smart Meters, i.e., meters with PMU-like capabilities. Our study shows how GSM/GPRS and LTE cellular...... system performance behaves with the current and next generation smart meters traffic, where it is clearly seen that the PMU data will seriously challenge these wireless systems. We conclude by highlighting the possible solutions for upgrading the cellular standards, in order to cope with the upcoming...

  19. A Framework for Reliable Reception of Wireless Metering Data using Protocol Side Information

    DEFF Research Database (Denmark)

    Melchior Jacobsen, Rasmus; Popovski, Petar

    2013-01-01

    Stationary collectors reading wireless, battery powered smart meters, often operate in harsh channel conditions to cut network installation cost to a minimum, challenging the individual link to each meter. The desired performance measure is reliable reception of at least some data from as many...... as possible meters, rather than maximizing the number of received packets from one meter. We consider a method for improving the reliable reception in a metering system that operates under the constraints of the popular Wireless M-Bus protocol. We develop a framework for reliable reception in which we use...... the deterministic protocol structure to obtain side information and group the packets from the same meter. We derive the probability of falsely pairing packets from different senders in the simple case of no channel errors, and show through simulation and data from an experimental deployment the probability...

  20. Simulation a Disposable mass flow meter by an advanced FSI Modeling and Finite Element Analysis.

    OpenAIRE

    zadeh, Siavash Hooshmand

    2014-01-01

    Abstract -In this thesis a design of a Coriolis mass flow-meter is chosen by considering all advantages and disadvantages and the project requirements. The chosen geometry is imported into COMSOL, because modelling is implemented by FEM and two different physics should be coupled. To consider both applications of the device include measuring density and flow rate, modeling is divided into two parts: Coriolis density meter and Coriolis mass flow-meter. Both applications are based on Fluid Stru...

  1. Advanced Utility Metering; Period of Performance: April 23, 2002 - September 22, 2002

    Energy Technology Data Exchange (ETDEWEB)

    2003-09-01

    In support of federal agencies considering the approach to utility metering appropriate for their facilities, the U.S. Department of Energy Federal Energy Management Program offers this publication as an overview of options in metering technology, system architecture, implementation, and relative costs. It provides advanced metering systems information to help potential users specify, acquire, use, and expand systems. It also addresses basic security issues and provides case studies and information resources.

  2. A Method to Design Optimal Communication Architectures in Advanced Metering Infrastructures

    OpenAIRE

    Armendariz, Mikel; Johansson, Christian; Nordström, Lars; Yunta Huete, Angel; García Lobo, Miguel

    2017-01-01

    This paper proposes a method to determine the optimal communication architecture in advance metering infrastructures (AMI). The method starts by indicating suitable groups of meters that share similar characteristics such as distance to the secondary substation and mutual proximity. Then it connects each group of meters to the AMI-Head End through a communication architecture formed by wireless and Power Line Communication (PLC) technologies. The optimality criterion takes into account the Ca...

  3. Lessons from wet gas flow metering systems using differential measurements devices: Testing and flow modelling results

    Energy Technology Data Exchange (ETDEWEB)

    Cazin, J.; Couput, J.P.; Dudezert, C. et al

    2005-07-01

    A significant number of wet gas meters used for high GVF and very high GVF are based on differential pressure measurements. Recent high pressure tests performed on a variety of different DP devices on different flow loops are presented. Application of existing correlations is discussed for several DP devices including Venturi meters. For Venturi meters, deviations vary from 9% when using the Murdock correlation to less than 3 % with physical based models. The use of DP system in a large domain of conditions (Water Liquid Ratio) especially for liquid estimation will require information on the WLR This obviously raises the question of the gas and liquid flow metering accuracy in wet gas meters and highlight needs to understand AP systems behaviour in wet gas flows (annular / mist / annular mist). As an example, experimental results obtained on the influence of liquid film characteristics on a Venturi meter are presented. Visualizations of the film upstream and inside the Venturi meter are shown. They are completed by film characterization. The AP measurements indicate that for a same Lockhart Martinelli parameter, the characteristics of the two phase flow have a major influence on the correlation coefficient. A 1D model is defined and the results are compared with the experiments. These results indicate that the flow regime influences the AP measurements and that a better modelling of the flow phenomena is needed even for allocation purposes. Based on that, lessons and way forward in wet gas metering systems improvement for allocation and well metering are discussed and proposed. (author) (tk)

  4. 18 CFR 430.19 - Ground water withdrawal metering, recording, and reporting.

    Science.gov (United States)

    2010-04-01

    .... Withdrawals shall be measured by means of an automatic continuous recording device, flow meter, or other...): Agricultural irrigation; snowmaking; dewatering incidental to mining and quarrying; dewatering incidental to...

  5. Using Smart Meters Data for Energy Management Operations and Power Quality Monitoring in a Microgrid

    DEFF Research Database (Denmark)

    Palacios-Garcia, Emilio J.; Diaz, Enrique Rodriguez; Anvari-Moghaddam, Amjad

    2017-01-01

    Smart metering devices have become an essential part in the development of the current electrical network toward the paradigm of Smart Grid. These meters present in most of the cases, functionalities whose analysis capabilities go further beyond the basic automated meter readings for billing...... of a commercial advanced metering infrastructure (AMI) in the context of a smart building with an energy management system (EMS). Furthermore, power quality monitoring based on this AMI is explained. All the details regarding the implementation in a laboratory scale application, as well as the obtained results...

  6. Meter-long microbial ropes from euxinic cave lakes

    Science.gov (United States)

    Macalady, J. L.; Jones, D. S.; Schaperdoth, I.; Bloom, D.; McCauley, R.

    2008-12-01

    Cave divers exploring a remote conduit in the Frasassi cave system (Italy) discovered unusual 1 to 2 meter- long, rope-like microbial biofilms in the anoxic layer of a permanently stratified cave lake. Organic carbon in the rope-like biofilm has a delta 13C value of -33 per mil, indicating in situ lithautotrophic primary production and little or no input from surface-derived plant carbon. SEM/EDS of critical point dried samples showed interlocking strands of microbial-sized filaments with trapped mineral particles including S, CaCO3, silicate clays, and sulfate and phosphate minerals. Staining with the nucleic acid dye DAPI further showed that the ropes are composed of closely packed, intact microbial cells. Geochemical profiles of the stratified lake (conductivity, pH, ORP, T, oxygen, sulfide, sulfate, ammonium) delineate a sharp chemocline at ~2.3 m water depth, several meters above the ropes. Geochemical data for the water surrounding the microbial ropes suggest that little redox energy is available, and that sulfate reduction and methanogenesis should be the most favorable reactions. Radiocarbon ages for the ropes are associated with a large uncertainty due to potentially changing contributions of radiocarbon-dead limestone carbonate over time. However, the data suggest that the ropes are thousands of years older than animals in the cave system, consistent with extreme energy limitation and slow growth. Based on phylogenetic analyses of archaeal, bacterial and universal 16S rDNA clone libraries from the microbial ropes, approximately 50 percent of bacterial clones affiliate with sulfur-reducing deltaproteobacteria. Approximately 61 percent of archaeal clones (20 percent of all clones) are associated with an environmental clade of euryarchaeota commonly retrieved from deep sea sediments (MBG-D). Most other clones in the libraries grouped in clades without cultivated representatives. No clones associated with known methanogens or anaerobic methane oxidizers were

  7. An Improved Platform Levelling System for Airborne Gravity Meters.

    Science.gov (United States)

    Brady, N.

    2014-12-01

    Recent advances in sensor technology have enabled Lacoste and Romberg type relative gravity meters to improve in accuracy to the point where other non-sensor related sources of error serve to limit the overall accuracy of the system. One of these sources of error is derived from the inability of the platform, in which the sensor is mounted, to keep the sensor perfectly level during survey flight. Off level errors occur when the aircraft is unable to maintain straight and level flight along a survey line. The levelling platform of a typical Lacoste and Romberg type dynamic gravity meter utilizes a complex feedback loop involving both accelerometers and gyroscopes with an output connected to torque motors mounted to the platform to sense an off level situation and correct for it. The current system is limited by an inability of the platform to distinguish between an acceleration of the platform due to a change in heading, altitude or speed of the aircraft and a true change in the local gravity vertical. Both of these situations cause the platform to tilt in reponse however the aircraft acceleration creates an error in the gravity measurement. These off level errors can be corrected for to a limited degree depending on the algorithm used and the size and duration of the causal acceleration. High precision GPS now provides accurate real time position information which can be used to determine if an accleration is a real level change or due to an anomalous acceleration. The correct implementation of the GPS position can significantly improve the accuracy of the platform levelling including keeping the platform level during course reversals or drape flying during a survey. This can typically improve the quality of the gravity data before any processing corrections. The enhanced platform also reduces the time taken to stabilize the platform at the beginning of a survey line therefore improving the efficiency of the data collection. This paper discusses the method and

  8. Hybrid ROV For 11,000 Meter Operations

    Science.gov (United States)

    Bowen, A. D.; Yoerger, D. R.; Whitcomb, L. L.

    2003-12-01

    The goal of this project is to provide the U.S. oceanographic community with the first capable and cost effective technology for regular and systematic access to the world's oceans to 11,000 meters. The vehicle will be able to operate untethered as a fully autonomous vehicle and also as a self-powered vehicle employing a 3mm diameter optical fiber tether for real-time telemetry of data and video to its human operators on a surface ship. We term this new class of vehicle a Hybrid Remotely Operated Vehicle (HROV). For the past 50 years, vehicle limitations have restricted direct access to depths of 6,500 m or less. Only a few deeper vehicles have ever been developed, notably the Trieste, which Piccard and Walsh piloted to the floor of the Marianas Trench in January 1960 and Japan's Kaiko ROV, which dove to 10,912 m depth in 1995. These deep deployments did not produce substantive scientific research results, indeed the technical and practical limitations rendered these efforts largely engineering trials. The scientific community has established the imperative to investigate the deep ocean floor at depths below 6500 m, yet a lacuna of practical technology prevents routine access to the deepest ocean. This virtually unexplored area of the ocean includes a wide range of tectonic regimes that pose significant questions about broad, fundamental problems in the earth and ocean sciences. The proposed HROV described in this poster will have capabilities of both an AUV and ROV. While operating untethered, the vehicle will operate as a traditional AUV, which has proven highly effective for a variety of survey operations. While connected to the surface with a lightweight fiber optic tether, high bandwidth two-way communications will permit the return of high quality video and sensor data, enabling close-up inspection, sampling, and instrument deployment/recovery operations to be conducted under the command of pilots and scientists onboard a research vessel. Our vehicle concept

  9. Recharge Net Metering to Incentivize Sustainable Groundwater Management

    Science.gov (United States)

    Fisher, A. T.; Coburn, C.; Kiparsky, M.; Lockwood, B. S.; Bannister, M.; Camara, K.; Lozano, S.

    2016-12-01

    Stormwater runoff has often been viewed as a nuisance rather than a resource, but with passage of the Sustainable Groundwater Management Act (2014), many basins in California are taking a fresh look at options to enhance groundwater supplies with excess winter flows. In some basins, stormwater can be used for managed aquifer recharge (MAR), routing surface water to enhance groundwater resources. As with many public infrastructure programs, financing for stormwater-MAR projects can be a challenge, and there is a need for incentives that will engage stakeholders and offset operation and maintenance costs. The Pajaro Valley Water Management Agency (PVWMA), in central costal California, recently launched California's first Recharge Net Metering (ReNeM) program. MAR projects that are part of the ReNeM program are intended to generate ≥100 ac-ft/yr of infiltration benefit during a normal water year. A team of university and Resource Conservation District partners will collaborate to identify and assess potential project sites, screening for hydrologic conditions, expected runoff, ease and cost of project construction, and ability to measure benefits to water supply and quality. The team will also collect data and samples to measure the performance of each operating project. Groundwater wells within the PVWMA's service area are metered, and agency customers pay an augmentation fee for each unit of groundwater pumped. ReNeM projects will earn rebates of augmentation fees based on the amount of water infiltrated, with rebates calculated using a formula that accounts for uncertainties in the fate of infiltrated water, and inefficiencies in recovery. The pilot ReNeM program seeks to contribute 1000 ac-ft/yr of infiltration benefit by the end of the initial five-year operating period. ReNeM offers incentives that are distinct from those derived from traditional groundwater banking, and thus offers the potential for an innovative addition to the portfolio of options for

  10. Use of requirements engineering within the Thirty Meter Telescope project

    Science.gov (United States)

    Rogers, John; Thompson, Hugh

    2010-07-01

    The Thirty Meter Telescope is comprised of thirty five individual sub-systems which include optical systems, instruments, adaptive optics systems, controls, mechanical systems, supporting software and hardware and the infrastructure required to support their operation. These thirty five sub-systems must operate together as a system to enable the telescope to meet the science cases for which it is being developed. These science cases are formalized and expressed as science requirements by the project's Science Advisory Committee. From these, a top down requirements engineering approach is used within the project to derive consistent operational, architectural and ultimately detailed design requirements for the sub-systems. The various layers of requirements are stored within a DOORS requirements database that also records the links between requirements, requirement rationale and requirement history. This paper describes the development of the design requirements from science cases, the reasons for recording the links between requirements and the benefits that documenting this traceability will yield during the design and verification of the telescope. Examples are given of particular science cases, the resulting operational and engineering requirements on the telescope system and how individual sub-systems will contribute to these being met.

  11. Study of Polyurethane Foaming Dynamics Using a Heat Flow Meter

    Science.gov (United States)

    Koniorczyk, P.; Trzyna, M.; Zmywaczyk, J.; Zygmunt, B.; Preiskorn, M.

    2017-05-01

    This work presents the results of the study concerning the effects of fillers addition on the heat flux density \\dot{q}( t ) of foaming of polyurethane-polystyrene porous composite (PSUR) and describes the dynamics of this process during the first 600 s. This foaming process resulted in obtaining porous materials that were based on HFC 365/225 blown rigid polyurethane foam (PUR) matrix, which contained thermoplastic expandable polystyrene (EPS) beads as the filler. In PSUR composites, the EPS beads were expanded after being heated to a temperature above the glass transition temperature of EPS and vaporing gas incorporated inside, by using the heat of exothermic reaction of polyol with isocyanate. From the start (t=0) to the end of the PSUR composite foaming process (t=tk), \\dot{q}( t ) was measured with the use of the heat flow meter. For the purpose of the study two PUR systems were selected: one with high and one with low heat density of foaming process q. EPS beads were selected from the same manufacturer with large and small diameter. The mass fraction of EPS in PSUR foam varied during the measurements. Additionally, a study of volume fractions of expanded EPS phase in PSUR foams as a function of mass fractions of EPS was conducted. In order to verify effects of the EPS addition on the heat flux density during PSUR foaming process, the thermal conductivity measurements were taken.

  12. Analysis of in-situ spectral absorption meter data

    Science.gov (United States)

    Zaneveld, J. Ronald V.; Kitchen, James C.; Bricaud, Annick; Moore, Casey C.

    1992-12-01

    In situ absorption data collected with a reflective-tube absorption meter are presented. Various procedures for correcting the data for scattering error and for extracting chlorophyll absorption from the raw signal are explored. Based on our knowledge of the distribution of particle types and on measured backscattering, the scattering correction as a function of total scattering is found to vary significantly with depth. However, absorption in the near infrared is shown to be highly correlated with backscattering. We thus postulate that this signal is mainly due to the scattering error and possibly to absorption by dissolved substances and particles of a detrital nature. Thus, the infrared signal seems to provide a good correction for the measured a(676) to obtain chloropigment absorption. Indeed, a(676) - a(750) (corrected for water absorption and 750 temperature dependence) was found to correlate strongly with fluorescence. However, a(750) was found to be highly temperature dependent, so a(712) was chosen for this purpose in future measurements. An examination of optical microstructure in East Sound, Orcas Island, Washington showed numerous peaks with vertical dimensions of the order of tens of centimeters. These peaks may contain the majority of the biomass in the system. The relative magnitude of the a(676) - a(712) and the a(712) signals varied greatly from one peak to another and systematically with depth, presumably reflecting the nature and physiological states of the populations in the various peaks.

  13. Analytical sizing methods for behind-the-meter battery storage

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Di; Kintner-Meyer, Michael; Yang, Tao; Balducci, Patrick

    2017-08-01

    In behind-the-meter application, battery storage system (BSS) is utilized to reduce a commercial or industrial customer’s payment for electricity use, including energy charge and demand charge. The potential value of BSS in payment reduction and the most economic size can be determined by formulating and solving standard mathematical programming problems. In this method, users input system information such as load profiles, energy/demand charge rates, and battery characteristics to construct a standard programming problem that typically involve a large number of constraints and decision variables. Such a large scale programming problem is then solved by optimization solvers to obtain numerical solutions. Such a method cannot directly link the obtained optimal battery sizes to input parameters and requires case-by-case analysis. In this paper, we present an objective quantitative analysis of costs and benefits of customer-side energy storage, and thereby identify key factors that affect battery sizing. Based on the analysis, we then develop simple but effective guidelines that can be used to determine the most cost-effective battery size or guide utility rate design for stimulating energy storage development. The proposed analytical sizing methods are innovative, and offer engineering insights on how the optimal battery size varies with system characteristics. We illustrate the proposed methods using practical building load profile and utility rate. The obtained results are compared with the ones using mathematical programming based methods for validation.

  14. Musical Meter Modulates the Allocation of Attention across Time.

    Science.gov (United States)

    Fitzroy, Ahren B; Sanders, Lisa D

    2015-12-01

    Dynamic attending theory predicts that attention is allocated hierarchically across time during processing of hierarchical rhythmic structures such as musical meter. ERP research demonstrates that attention to a moment in time modulates early auditory processing as evidenced by the amplitude of the first negative peak (N1) approximately 100 msec after sound onset. ERPs elicited by tones presented at times of high and low metric strength in short melodies were compared to test the hypothesis that hierarchically structured rhythms direct attention in a manner that modulates early perceptual processing. A more negative N1 was observed for metrically strong beats compared with metrically weak beats; this result provides electrophysiological evidence that hierarchical rhythms direct attention to metrically strong times during engaged listening. The N1 effect was observed only on fast tempo trials, suggesting that listeners more consistently invoke selective processing based on hierarchical rhythms when sounds are presented rapidly. The N1 effect was not modulated by musical expertise, indicating that the allocation of attention to metrically strong times is not dependent on extensive training. Additionally, changes in P2 amplitude and a late negativity were associated with metric strength under some conditions, indicating that multiple cognitive processes are associated with metric perception.

  15. Improvement of PLL algorithm for the LEP Q-meter

    CERN Document Server

    Berrig, O E

    1998-01-01

    The PLL (Phase Locked Loop) has two modes: search mode and locking mode. The mode is determined by how far apart the internal frequency is from the external frequency. When the internal - and exter nal frequencies are close, the PLL is in locking mode. While locking on the external frequency, the PLL can largely be expressed as a linear term superimposed with a small "noise" term. We can t herefore calculate a transfer function that will completely describe the performance of the PLL apart from the precision, which is determined by the noise term. Two ideas are presented on how to re duce the noise term. The first idea is to compensate the noise term with an equal value of opposite sign. This completely removes the noise when the PLL locks on a steady frequency. Unfortunately it can not be used for the LEP Q-meter which is plagued by the presence of satellite frequencies. For other equipment with cleaner spectra, the method can improve their precision dramatically. T he second idea reduces the noise level wit...

  16. Radio observation of Venus at meter wavelengths using the GMRT

    Science.gov (United States)

    Mohan, Nithin; Roy, Subhashis; Swarup, Govind; Oberoi, Divya; Ramanujam, Niruj Mohan; Suresh Raju, C.; Bhardwaj, Anil

    2017-11-01

    The Venusian surface has been studied by measuring radar reflections and thermal radio emission over a wide spectral region of several centimeters to meter wavelengths from the Earth-based as well as orbiter platforms. The radiometric observations, in the decimeter (dcm) wavelength regime showed a decreasing trend in the observed brightness temperature (Tb) with increasing wavelength. The thermal emission models available at present have not been able to explain the radiometric observations at longer wavelength (dcm) to a satisfactory level. This paper reports the first interferometric imaging observations of Venus below 620 MHz. They were carried out at 606, 332.9 and 239.9 MHz using the Giant Meterwave Radio Telescope (GMRT). The Tb values derived at the respective frequencies are 526 K, 409 K and <426 K, with errors of ∼7% which are generally consistent with the reported Tb values at 608 MHz and 430 MHz by previous investigators, but are much lower than those derived from high-frequency observations at 1.38-22.46 GHz using the VLA.

  17. Electricity Submetering on the Cheap: Stick-on Electricity Meters

    Energy Technology Data Exchange (ETDEWEB)

    Lanzisera, Steven; Lorek, Michael; Pister, Kristofer

    2014-08-17

    We demonstrate a low-cost, 21 x 12 mm prototype Stick-on Electricity Meter (SEM) to replace traditional in-circuit-breaker-panel current and voltage sensors for building submetering. A SEM sensor is installed on the external face of a circuit breaker to generate voltage and current signals. This allows for the computation of real and apparent power as well as capturing harmonics created by non-linear loads. The prototype sensor is built using commercially available components, resulting in a production cost of under $10 per SEM. With no highvoltage install work requiring an electrician, home owners or other individuals can install the system in a few minutes with no safety implications. This leads to an installed system cost that is much lower than traditional submetering technology.. Measurement results from lab characterization as well as a real-world residential dwelling installation are presented, verifying the operation of our proposed SEM sensor. The SEM sensor can resolve breaker power levels below 10W, and it can be used to provide data for non-intrusive load monitoring systems at full sample rate.

  18. The LBL 55-meter spherical grating monochromator at SSRL

    Science.gov (United States)

    McKinney, W. R.; Howells, M. R.; Lauritzen, T.; Chin, J.; DiGennaro, R.; Fong, E.; Gath, W.; Guigli, J.; Hogrefe, H.; Meneghetti, J.; Plate, D.; Heimann, P. A.; Terminello, L.; Ji, Z.; Shirley, D.; Senf, F.

    1990-05-01

    A 55 meter spherical grating monochromator has been completed at the Stanford Synchrotron Radiation Laboratory (SSRL). The monochromator includes a unique capability for water cooled gratings, and is presently operating with a fused silica grating from 180 to 820 eV. A resolution of 60 meV has been achieved at 400 eV, inferred from the linewidths of the nitrogen 1s-π∗ resonance. A photon flux of 4 × 10 10 photon/s has been observed at 440 eV and 40 mA ring current (and with 0.5 eV resolution). It is expected that this flux value will improve by a factor of approximately 10-30 when a full-performance condensing system is installed later this year. The optical and mechanical systems design of the Rowland Circle monochromator with moving entrance and exit slits is reviewed. The details of the laser interferometer encoded wavelength drive, the mounting of the water cooled gratings, and the mechanical design features which improve the stability and accuracy of the system are described. The alignment of the gratings, grating chamber, and slits is discussed.

  19. PELATIHAN RENANG GAYA DADA 8 KALI 25 METER 4 SET LEBIH MENINGKATKAN KECEPATAN RENANG 100 METER GAYA DADA DARIPADA 4 KALI 50 METER 4 SET PADA RENANG PEMULA PUTRA

    Directory of Open Access Journals (Sweden)

    I Wayan Suarta

    2013-07-01

    Full Text Available Sports pool in Indonesia are well known to the public, which is reduced when driving (after the end of the recovery to begin hand pull another hand, the breaststroke is the style of the most interesting because it does not quickly tiring when compared with other styles, because the process of respiration take place with ease, making them easier use in long-distance swim, at the start to affect the pace to continue this next movement needs to get training and a variety of training models, especially at students aged 10-12 years. Training pool 8 times 25 times 50 meters and 4 meters is one of the training methods that can speed up travel time. The best training model has not been encountered in the data. So do the research to find a model training 25 meter pool 8 times and 4 times 4 sets of 50 meters. The study was conducted with pretest-postes group design. Samples taken from the novice swimmer Toya Ening on Dalung Badung, as many as 26 people were randomly selected simple. Samples were divided into 2 groups each group totaled 13 people. Both groups were equally give training in the first group to pool 8 by 25 feet 4 sets, and 4 times the second group of 4 sets of 50 meters. 0.05 ab. Differences in results were analyzed statistically with  The data analyzed were age, height, weight, leg length and physical fitness.  13.49 seconds.± 107.69, and 126.38 ±The mean test results of the final 100 meter breaststroke swimming in a row 12.14 seconds  F count the results obtained respectively by 0.95 seconds with p = 0.59 and 0.93 seconds with a value of p = 0.34. Data showed significant differences significant (p> 0.05. These results indicate that the training of swimming the breaststroke 8 by 25 feet 4 sets is better than 4 times in 4 sets of 50 meter speed up travel time 100-meter breaststroke swimming novice men (p <0.05. Suggested the use of breaststroke swimming training method 8 by 25 feet 4 sets to be intensified to provide training pool at 100

  20. Design and Realization of a Condition Management System for the Gateway Electrical Energy Metering Device

    Directory of Open Access Journals (Sweden)

    Chao Tang

    2013-12-01

    Full Text Available With the construction of firm and intelligent power grid in China, it is difficult for the traditional management method of electrical energy metering device to meet the prospecting requirements. Using the computer and internet techniques to realize the information and intelligentization of the electrical energy metering management has become a necessary guarantee of improving power supply ability, marketing control, and customer service. This paper introduced a kind of large and intelligent condition management system of the gateway electrical energy metering device. The key technologies and realize process were analyzed. Moreover, a detailed description of the application modules such as the GIS smart display of metering point, the condition management of metering devices and the visual monitoring of metering point was presented. The trial operation in the selected transformer substations and the power stations of Chongqing Power Electrical Corp. indicated that, the condition management system is very open, safety and efficient. According to the data exchange with the production and scheduling platform, the system improved the efficient operation of the electrical energy metering devices. Meanwhile, combined with the real-time visual monitoring, the condition management system improved the prevention ability of electricity filching, realized the unified automatic large-scale management of electrical energy metering devices.

  1. Optimal Dimensioning of FiWi Networks over Advanced Metering Infrastructure for the Smart Grid

    DEFF Research Database (Denmark)

    Inga, Esteban; Peralta-Sevilla, Arturo; Hincapié, Roberto

    2015-01-01

    —In this paper, we propose a hybrid wireless mesh network infrastructure which connects the smart meters of each consumer with the data aggregation points (DAP). We suppose a set of smart meters that need to send information, and receive information from a central office on electrical enterprises...

  2. A low cost field usable portable digital grain moisture meter with ...

    African Journals Online (AJOL)

    We have developed a grain moisture meter, which due to its novel design, eliminates this problem and gives moisture (%) directly on a LCD display. The novelty of this instrument is that it is compact, easy-to-use, portable, and field usable. The moisture meter is based on the principle of dielectric constant variations due to ...

  3. 21 CFR 868.1860 - Peak-flow meter for spirometry.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Peak-flow meter for spirometry. 868.1860 Section 868.1860 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... spirometry. (a) Identification. A peak-flow meter for spirometry is a device used to measure a patient's...

  4. Integration of Remote Blood Glucose Meter Upload Technology into a Clinical Pharmacist Medication Therapy Management Service

    OpenAIRE

    Schenk, Robert J.; Schenk, Jenna

    2011-01-01

    A pharmacist-delivered, outpatient-focused medication therapy management (MTM) program is using a remote blood glucose (BG) meter upload device to provide better care and to improve outcomes for its patients with diabetes. Sharing uploaded BG meter data, presented in easily comprehensible graphs and charts, enables patients, caregivers, and the medical team to better understand how the patients’ diabetes care is progressing.

  5. Artificial Intelligence Techniques and the Smart Grid: Towards Smart Meter Convenience While Maintaining Privacy

    NARCIS (Netherlands)

    Lodder, A.R.; Wisman, T.H.A.

    2015-01-01

    Smart meters are physically within the private sphere of the home. These meters are smart in that consumers can moderate their energy consumption based on generated electricity information. This information can be very detailed, both in terms of time intervals and the number of measuring points. As

  6. Privacy-Preserving Smart Metering with Authentication in a Smart Grid

    Directory of Open Access Journals (Sweden)

    Jun Beom Hur

    2015-12-01

    Full Text Available The traditional security objectives of smart grids have been availability, integrity, and confidentiality. However, as the grids incorporate smart metering and load management, user and corporate privacy is increasingly becoming an issue in smart grid networks. Although transmitting current power consumption levels to the supplier or utility from each smart meter at short intervals has an advantage for the electricity supplier’s planning and management purposes, it threatens user privacy by disclosing fine-grained consumption data and usage behavior to utility providers. In this study, we propose a distributed incremental data aggregation scheme where all smart meters on an aggregation path are involved in routing the data from the source meter to the collection unit. User privacy is preserved by symmetric homomorphic encryption, which allows smart meters to participate in the aggregation without seeing any intermediate or final result. Aggregated data is further integrated with an aggregate signature to achieve data integrity and smart meter authentication in such a way that dishonest or fake smart meters cannot falsify data en route. Only the collection unit can obtain the aggregated data and verify its integrity while the individual plain data are not exposed to the collection unit. Therefore, user privacy and security are improved for the smart metering in a smart grid network.

  7. Methodology of calibration for nucleonic multiphase meter technology for SAGD extra heavy oil

    Energy Technology Data Exchange (ETDEWEB)

    Pinguet, B.; Pechard, P.; Guerra, E. [Schlumberger Canada Ltd., Calgary, AB (Canada); Arendo, V.; Shaffer, M.; Contreras, J. [Total, Paris (France)

    2008-10-15

    The challenges facing bitumen metering in steam assisted gravity drainage operations were discussed with reference to high operating temperatures, steam pressure in the gas phase, foaming, emulsion and small density differences between bitumen and produced water. A metering tool that can deal with these operating constraints was presented. The multiphase meter (MFM) uses a multi-energy gamma ray (nuclear fraction) meter together with a venturi tube to provide accurate monitoring and optimization of oil, water, gas and steam production. This paper presented the specific strengths of the MFM with emphasis on its ability to correctly meter the liquid/gas phases depending on the calibration method and operating measurement range. The paper presented a study of the main parameters which could influence the measurement associated with this technology. The study was based on practical and simulated data and evaluated the impact of changes in each parameter. The purpose of the paper was to improve the understanding of this technology and how to apply it to bitumen metering and provide a guideline of the technology for future users in the oil industry. It described the combination venturi-nucleonic measurement parameters, such as mass flow rate; fraction meter; solution triangle of the fraction meter; primary and secondary output; fluid properties information; and uncertainty associated to any technology. A sensitivity analysis study to identify the dependency to some key fluid parameters was also described. It was concluded that MFM can be used in a stand-alone configuration. 7 refs., 2 tabs., 22 figs.

  8. Agreement of Power Measures between Garmin Vector and SRM Cycle Power Meters

    Science.gov (United States)

    Novak, Andrew R.; Dascombe, Benjamin J.

    2016-01-01

    This study aimed to determine if the Garmin Vector (Schaffhausen, Switzerland) power meter produced acceptable measures when compared with the Schoberer Rad Messetechnik (SRM; Julich, Germany) power meter across a range of high-intensity efforts. Twenty-one well-trained cyclists completed power profiles (seven maximal mean efforts between 5 and…

  9. Probing attentive and preattentive emergent meter in adult listeners without extensive music training

    NARCIS (Netherlands)

    Ladinig, O.; Honing, H.; Háden, G.; Winkler, I.

    2009-01-01

    Beat and meter induction are considered important structuring mechanisms underlying the perception of rhythm. Meter comprises two or more levels of hierarchically ordered regular beats with different periodicities. When listening to music, adult listeners weight events within a measure in a

  10. Apollo 16 mission anomaly report no. 9: Lunar roving vehicle electrical system meter anomalies

    Science.gov (United States)

    1973-01-01

    The off-scale low indications of the voltmeters for batteries one and two at initial powerup of the Apollo 16 lunar roving vehicle were analyzed. No single condition was found that would explain the anomalous meter indications. It is concluded that the intermittent conditions must have existed in the multiple wire splices to the meters.

  11. Fission Meter Information Barrier Attribute Measurement System: Task 1 Report: Document existing Fission Meter neutron IB system

    Energy Technology Data Exchange (ETDEWEB)

    Kerr, P. L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-02-28

    An SNM attribute Information Barrier (IB) system was developed for a 2011 US/UK Exercise. The system was modified and extensively tested in a 2013-2014 US-UK Measurement Campaign. This work demonstrated rapid deployment of an IB system for potential treaty use. The system utilizes an Ortec Fission Meter neutron multiplicity counter and custom computer code. The system demonstrates a proof-of-principle automated Pu-240 mass determination with an information barrier. After a software start command is issued, the system automatically acquires and downloads data, performs an analysis, and displays the results. This system conveys the results of a Pu mass threshold measurements in a way the does not reveal sensitive information. In full IB mode, only red/green ‘lights’ are displayed in the software. In test mode, more detailed information is displayed. The code can also read in, analyze, and display results from previously acquired or simulated data. Because the equipment is commercial-off-the-shelf (COTS), the system demonstrates a low-cost short-lead-time technology for treaty SNM attribute measurements. A deployed system will likely require integration of additional authentication and tamper-indicating technologies. This will be discussed for the project in this and future progress reports.

  12. Development of a moisture meter for milled layer. Jyrsoeksen kosteusmittarin kehittaeminen

    Energy Technology Data Exchange (ETDEWEB)

    Aho, V.J.; Leinonen, A.; Hyvaerinen, T.

    1989-02-01

    The purpose of the present paperis to report the development of a continuously operating moisture meter for milled peat layer. The moisture meter is based on the NIR (Near Infra-red) reflection measuring technique. The meter's detector consists of a Near Infra-red radiation detector, elements for optical measuring, a two-channel Infra-red detector, and an electronic signal processor. This moisture meter system also contains a field operable microcomputer for storing measurement data and a printer for taking print-outs during the measurements. The detector and its accessories are installed onto a carriage which can be pulled along on a bog. The results from various measuring tests, and the differences between these results and the results obtained from measuring samples taken by hand are reported. In addition, the paper describes experiences received from using the homogenization equipment. An lastly, plans for further development of the continuously operating and field operable moisture meter for milled layer are outlined.

  13. Blood glucose meters and accessibility to blind and visually impaired people.

    Science.gov (United States)

    Burton, Darren M; Enigk, Matthew G; Lilly, John W

    2012-03-01

    In 2007, five blood glucose meters (BGMs) were introduced with integrated speech output necessary for use by persons with vision loss. One of those five meters had fully integrated speech output, allowing a person with vision loss independence in accessing all features and functions of the meter. In comparison, 13 BGMs with integrated speech output were available in 2011. Accessibility attributes of these 11 meters were tabulated and product design features examined. All 13 meters were found to be usable by persons with vision loss to obtain a blood glucose measurement. However, only 4 of them featured the fully integrated speech output necessary for a person with vision loss to access all features and functions independently. © 2012 Diabetes Technology Society.

  14. The VDEW-meter and its saving potential; Der VDEW-Zaehler und sein Sparpotential

    Energy Technology Data Exchange (ETDEWEB)

    Scheew, P. [EMH Energie-Messtechnik GmbH und Co. KG, Brackel (Germany)]|[EMH Elektrizitaetszaehler GmbH und Co. KG, Wittenburg (Germany)

    1998-01-12

    Up to 20 years ago, electricity meters had measured according to an electromechanical measurement principle. Electronic solutions could not match these mechanic meters in terms of accuracy, reliability, durability, or price. In the meantime, however, electronics experienced a unique evolution. Nowadays electricity meters are manufactured on an industrial scale, using the latest micro-electronics. Electronic electricity meters are not only competing easily with traditional meters but also providing the means to combine several components within a single compact housing. (orig.) [Deutsch] Bis vor 20 Jahren arbeiteten Elektrizitaetszaehler nach dem elektromechanischen Messprinzip. Genauigkeit, Zuverlaessigkeit, Lebensdauer und Preis konnten von elektronischen Loesungen nicht erreicht werden. Inzwischen hat die Elektronik eine einzigartige Entwicklung erlebt. Heute werden unter Einsatz modernster Mikroelektronik Elektrizitaetszaehler industriell hergestellt, die nicht nur mit Zaehlern herkoemmlicher Technik muehelos konkurrieren koennen, sondern wegen ihrer grossen Integrationsdichte ein Zusammenlegen mehrerer Komponenten in ein Gehaeuse ermoeglichen. (orig.)

  15. Allocation of Power Meters for Online Load Distribution Estimation in Smart Grids

    DEFF Research Database (Denmark)

    Kouzelis, Konstantinos; Diaz de Cerio Mendaza, Iker; Bak-Jensen, Birgitte

    2015-01-01

    The electrification of heating and transportation along with the penetration of renewable energy in electricity networks has necessitated the evolution of low voltage distribution grids into smart grids. Contemporary, smart grids are realised by smart meter installations to electricity end users....... In the literature, these meters aim at online metering of the grid status. Depending on this status, proactive and/or reactive load management can subsequently be conducted. In reality however, many smart grids perform this metering offline due to excessive data problems. As such, grid operators have reduced...... observability of the load distribution in their grid throughout the day. This paper investigates the possibility of improving the observability by allocating a minimum number of additional online operated power meters in the distribution grid. This allocation, driven by optimisation, clustering, and forecasting...

  16. Pharmaceutical Product Development: Intranasal Scopolamine (INSCOP) Metered Dose Spray

    Science.gov (United States)

    Putcha, Lakshmi; Crady, Camille; Putcha, Lakshmi

    2012-01-01

    Motion sickness (MS) has been a problem associated with space flight, the modern military and commercial air and water transportation for many years. Clinical studies have shown that scopolamine is the most effective medication for the prevention of motion sickness (Dornhoffer et al, 2004); however, the two most common methods of administration (transdermal and oral) have performance limitations that compromise its utility. Intranasal administration offers a noninvasive treatment modality, and has been shown to counter many of the problems associated with oral and transdermal administration. With the elimination of the first pass effect by the liver, intranasal delivery achieves higher and more reliable bioavailability than an equivalent oral dose. This allows for the potential of enhanced efficacy at a reduced dose, thus minimizing the occurrence of untoward side effects. An Intranasal scopolamine (INSCOP) gel formulation was prepared and tested in four ground-based clinical trials under an active Investigational New Drug (IND) application with the Food and Drug Administration (FDA). Although there were early indicators that the intranasal gel formulation was effective, there were aspects of formulation viscosity and the delivery system that were less desirable. The INSCOP gel formulation has since been reformulated into an aqueous spray dosage form packaged in a precise, metered dose delivery system; thereby enhancing dose uniformity, increased user satisfaction and palatability, and a potentially more rapid onset of action. Recent reports of new therapeutic indications for scopolamine has prompted a wide spread interest in new scopolamine dosage forms. The novel dosage form and delivery system of INSCOP spray shows promise as an effective treatment for motion sickness targeted at the armed forces, spaceflight, and commercial sea, air, and space travel markets, as well as prospective psychotherapy for mental and emotional disorders.

  17. Multiparametric Experiments and Multiparametric Setups for Metering Explosive Eruptions

    Science.gov (United States)

    Taddeucci, J.; Scarlato, P.; Del Bello, E.

    2016-12-01

    Explosive eruptions are multifaceted processes best studied by integrating a variety of observational perspectives. This need marries well with the continuous stream of new means that technological progress provides to volcanologists to parameterize these eruptions. Since decades, new technologies have been tested and integrated approaches have been attempted during so-called multiparametric experiments, i.e., short field campaigns with many, different instruments (and scientists) targeting natural laboratory volcanoes. Recently, portable multiparametric setups have been developed, including a few, highly complementary instruments to be rapidly deployed at any erupting volcano. Multiparametric experiments and setups share most of their challenges, like technical issues, site logistics, and data processing and interpretation. Our FAMoUS (FAst MUltiparametric Setup) setup pivots around coupled, high-speed imaging (visible and thermal) and acoustic (infrasonic to audible) recording, plus occasional seismic recording and sample collection. FAMoUS provided new insights on pyroclasts ejection and settling and jet noise dynamics at volcanoes worldwide. In the last years we conducted a series of BAcIO (Broadband ACquisition and Imaging Operation) experiments at Stromboli (Italy). These hosted state-of-the-art and prototypal eruption-metering technologies, including: multiple high-speed high-definition cameras for 3-D imaging; combined visible-infrared-ultraviolet imaging; in-situ and remote gas measurements; UAV aerial surveys; Doppler radar, and microphone arrays. This combined approach provides new understandings of the fundamental controls of Strombolian-style activity, and allows for crucial cross-validation of instruments and techniques. Several documentary expeditions participated in the BAcIO, attesting its tremendous potential for public outreach. Finally, sharing field work promotes interdisciplinary discussions and cooperation like nothing in the world.

  18. Sky Quality Meter measurements in a colour-changing world

    Science.gov (United States)

    Sánchez de Miguel, A.; Aubé, M.; Zamorano, J.; Kocifaj, M.; Roby, J.; Tapia, C.

    2017-05-01

    The Sky Quality Meter (SQM) has become the most common device used to track the evolution of the brightness of the sky from polluted regions to first-class astronomical observatories. A vast database of SQM measurements already exists for many places in the world. Unfortunately, the SQM operates over a wide spectral band and its spectral response interacts with the sky's spectrum in a complex manner. This is why the optical signals are difficult to interpret when the data are recorded in regions with different sources of artificial light. The brightness of the night sky is linked in a complex way to ground-based light emissions, while taking into account atmospheric-induced optical distortion as well as spectral transformation from the underlying ground surfaces. While the spectral modulation of the sky's radiance has been recognized, it still remains poorly characterized and quantified. The impact of the SQM's spectral characteristics on sky-brightness measurements is analysed here for different light sources, including low- and high-pressure sodium lamps, PC-amber and white LEDs, metal halide and mercury lamps. We show that a routine conversion of radiance to magnitude is difficult, or rather impossible, because the average wavelength depends on actual atmospheric and environment conditions, the spectrum of the source and device-specific properties. We correlate SQM readings with both the Johnson astronomical photometry bands and the human system of visual perception, assuming different lighting technologies. These findings have direct implications for the processing of SQM data and for their improvement and/or remediation.

  19. Liquid Metering Centrifuge Sticks (LMCS): A Centrifugal Approach to Metering Known Sample Volumes for Colorimetric Solid Phase Extraction (C-SPE)

    Science.gov (United States)

    Gazda, Daniel B.; Schultz, John R.; Clarke, Mark S.

    2007-01-01

    Phase separation is one of the most significant obstacles encountered during the development of analytical methods for water quality monitoring in spacecraft environments. Removing air bubbles from water samples prior to analysis is a routine task on earth; however, in the absence of gravity, this routine task becomes extremely difficult. This paper details the development and initial ground testing of liquid metering centrifuge sticks (LMCS), devices designed to collect and meter a known volume of bubble-free water in microgravity. The LMCS uses centrifugal force to eliminate entrapped air and reproducibly meter liquid sample volumes for analysis with Colorimetric Solid Phase Extraction (C-SPE). C-SPE is a sorption-spectrophotometric platform that is being developed as a potential spacecraft water quality monitoring system. C-SPE utilizes solid phase extraction membranes impregnated with analyte-specific colorimetric reagents to concentrate and complex target analytes in spacecraft water samples. The mass of analyte extracted from the water sample is determined using diffuse reflectance (DR) data collected from the membrane surface and an analyte-specific calibration curve. The analyte concentration can then be calculated from the mass of extracted analyte and the volume of the sample analyzed. Previous flight experiments conducted in microgravity conditions aboard the NASA KC-135 aircraft demonstrated that the inability to collect and meter a known volume of water using a syringe was a limiting factor in the accuracy of C-SPE measurements. Herein, results obtained from ground based C-SPE experiments using ionic silver as a test analyte and either the LMCS or syringes for sample metering are compared to evaluate the performance of the LMCS. These results indicate very good agreement between the two sample metering methods and clearly illustrate the potential of utilizing centrifugal forces to achieve phase separation and metering of water samples in microgravity.

  20. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    Science.gov (United States)

    Darghouth, Naim Richard

    Net metering has become a widespread policy mechanism in the U.S. for supporting customer adoption of distributed photovoltaics (PV), allowing customers with PV systems to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption. Although net metering is one of the principal drivers for the residential PV market in the U.S., the academic literature on this policy has been sparse and this dissertation contributes to this emerging body of literature. This dissertation explores the linkages between the availability of net metering, wholesale electricity market conditions, retail rates, and the residential bill savings from behind-the-meter PV systems. First, I examine the value of the bill savings that customers receive under net metering and alternatives to net metering, and the associated role of retail rate design, based on current rates and a sample of approximately two hundred residential customers of California's two largest electric utilities. I find that the bill savings per kWh of PV electricity generated varies greatly, largely attributable to the increasing block structure of the California utilities' residential retail rates. I also find that net metering provides significantly greater bill savings than alternative compensation mechanisms based on avoided costs. However, retail electricity rates may shift as wholesale electricity market conditions change. I then investigate a potential change in market conditions -- increased solar PV penetrations -- on wholesale prices in the short-term based on the merit-order effect. This demonstrates the potential price effects of changes in market conditions, but also points to a number of methodological shortcomings of this method, motivating my usage of a long-term capacity investment and economic dispatch model to examine wholesale price effects of various wholesale market scenarios in the subsequent analysis. By developing

  1. The NASA Meter Class Autonomous Telescope: Ascension Island

    Science.gov (United States)

    Lederer, S. M.; Stansbery, E. G.; Cowardin, H. M.; Hickson, P.; Pace, L. F.; Abercromby, K. J.; Kervin, P. W.

    2013-01-01

    The Meter Class Autonomous Telescope (MCAT) is the newest optical sensor dedicated to NASA's mission to characterize the space debris environment. It is the successor to a series of optical telescopes developed and operated by the JSC Orbital Debris Program Office (ODPO) to monitor and assess the debris environment in (1) Low Earth Orbit (LEO), (2) Medium Earth Orbit (MEO), and (3) Geosynchronous Orbit (GEO), with emphasis on LEO and GEO altitudes. A joint NASA - Air Force Research Labs project, MCAT is a 1.3m optical telescope dedicated to debris research. Its optical path and sensor yield a large survey fence at the cutting edge of current detector performance. It has four primary operational observing modes, two of which were not computationally feasible a decade ago. Operations are supported by a sophisticated software suite that monitors clouds and weather conditions, and controls everything from data collection to dome rotation to processing tens of gigabytes of image data nightly. With fainter detection limits, precision detection, acquisition and tracking of targets, multi-color photometry, precision astrometry, automated re-acquisition capability, and the ability to process all data at the acquisition rate, MCAT is capable of producing and processing a volume and quality of data far in excess of any current (or prior) ODPO operations. This means higher fidelity population inputs and eliminating the multi-year backlog from acquisition-to-product typical of optical campaigns. All of this is possible given a suitable observing location. Ascension Island offers numerous advantages. As a British overseas territory with a US Air Force base presence, the necessary infrastructure and support already exists. It is located mid-way between Brazil and Africa at 7.93S latitude and 14.37 W longitude. With the Ground-based Electro-Optical Deep Space Surveillance (GEODSS) asset in Moron, Spain shutting down, this presents access to the sky from a unique latitude

  2. Current meter data from moored current meter casts in the North Atlantic Ocean as part of the Outer Continental Shelf - South Atlantic (OCS-South Atlantic) project from 26 August 1980- 01 March 1981 (NODC Accession 8100540)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the North Atlantic Ocean from August 26, 1980 to March 1, 1980. Data were submitted by Science...

  3. Current meter data from moored current meter casts in the North American Coastline-South as part of the Florida Atlantic Coastal Transport Study (FACTS) project 07 March 1984 - 01 September 1985 (NODC Accession 8600136)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the North American Coastline-South from March 7, 1984 to September 1, 1985. Data were submitted...

  4. Current meter data from moored current meter casts in the Puget Sound as part of the Mesa Puget Sound/PSERP project, 14 December 1977 - 19 April 1978 (NODC Accession 8000053)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Puget Sound from December 14, 1977 to April 19, 1978. Data were submitted by Pacific Marine...

  5. Current meter data from moored current meter casts in the Puget Sound as part of the Mesa Puget Sound/PSERP project, 17 June 1977 - 01 August 1977 (NODC Accession 7800337)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Puget Sound from June 17, 1977 to August 1, 1977. Data were submitted by University of the...

  6. Current meter data from moored current meter casts in the Northeast Pacific Ocean as part of the Flow Over Abrupt Topography project from 06 January 1990 - 03 December 1991 (NODC Accession 9500077)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Northeast Pacific Ocean from January 6, 1990 to December 3, 1991. Data were submitted by...

  7. Current meter data from moored current meter casts in the Puget Sound as part of the Long-Range Effects Program Puget Sound project from 1979-08-02 to 1980-04-09 (NODC Accession 9600006)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Puget Sound from August 2, 1979 to April 9, 1980. Data were submitted by Pacific Marine...

  8. Current meter data from moored current meter casts in the Puget Sound as part of the Long-Range Effects Program Puget Sound project from 1983-11-29 to 1984-08-01 (NODC Accession 8800119)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Puget Sound from November 29, 1983 to August 1, 1984. Data were submitted by Pacific Marine...

  9. Current meter data from moored current meter casts in the North American Coastline-South as part of the Outer Continental Shelf Baltimore Canyon Study, 17 April 1981 - 01 November 1982 (NODC Accession 8500009)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the North American Coastline-South from April 17, 1981 to November 1, 1982. Data were submitted...

  10. Current meter components, physical, and other data from current meters and CTD casts from NOAA Ship RONALD H. BROWN and other platforms as part of the VENTS program from 14 June 1996 to 05 October 1997 (NODC Accession 9800031)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter components and physical data were collected from current meters and CTD casts from NOAA Ship RONALD H. BROWN and other platforms from 14 June 1996 to...

  11. Current meter, and other data from current meter from the AKADEMIK KURCHATOV as part of the GARP (Global Atmospheric Research Program) Atlantic Tropical Experiment (GATE) project, 29 July 1974 - 15 August 1974 (NODC Accession 7601678)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter, and other data were collected using current meter from the AKADEMIK KURCHATOV from July 29, 1974 to August 15, 1974. Data were submitted by a station...

  12. Current meter data from moored current meter casts and other instruments in the Northwest and Southwest Pacific Ocean from 01 October 1992 to 15 March 1993 (NODC Accession 9400088)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts and other instruments in the Northwest and Southwest Pacific Ocean from October 1, 1992 to March...

  13. Current meter data from moored current meter casts in the Pacific Ocean as part of the Equatorial Pacific Ocean Climate Studies (EPOCS) project from 1990-04-30 to 1991-05-15 (NODC Accession 9400005)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Pacific Ocean from April 30, 1990 to May 15, 1991. Data were submitted by Pacific Marine...

  14. Current meter data from moored current meter casts in the Pacific Ocean as part of the Equatorial Pacific Ocean Climate Studies (EPOCS) project from 1979-01-20 to 1984-04-01 (NODC Accession 8700077)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Pacific Ocean from January 20, 1979 to April 1, 1984. Data were submitted by Pacific Marine...

  15. Current meter data from moored current meter casts in the South Pacific Ocean as part of the Equatorial Pacific Ocean Climate Studies (EPOCS) project from 1981-11-21 to 1983-11-20 (NODC Accession 8500258)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the South Pacific Ocean from November 21, 1981 to November 20, 1983. Data were submitted by...

  16. Current meter and other data from current meter casts from NOAA Ship RESEARCHER in the North and South Pacific Ocean from 1984-06-28 to 1984-07-01 (NODC Accession 8500226)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter and other data were collected using current meter casts from NOAA Ship RESEARCHER in the North/South Pacific Ocean from June 28, 1984 to July 1, 1984....

  17. Current meter and temperature profile data from current meter and buoy casts in the TOGA area of Pacific Ocean from 27 April 1993 to 09 June 1994 (NODC Accession 9700042)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter and temperature profile data were collected using current meter and buoy casts in the TOGA area of Pacific Ocean from 27 April 1993 to 09 June 1994....

  18. Current meter data from moored current meter casts in the Pacific Ocean as part of the Equatorial Pacific Ocean Climate Studies (EPOCS) project from 1979-01-20 to 1984-04-26 (NODC Accession 8500007)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Pacific Ocean from January 20, 1979 to April 26, 1984. Data were submitted by Pacific...

  19. Current meter data from moored current meter casts in the Pacific Ocean as part of the Equatorial Pacific Ocean Climate Studies (EPOCS) project from 1986-05-28 to 1987-05-11 (NODC Accession 8900168)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Pacific Ocean from 28 May 1986 to 01 May 1983. Data were submitted by Pacific Marine...

  20. Current meter data from moored current meter casts in the Columbia River estuary - Washington/Oregon as part of the Low Level Waste Ocean Disposal project from 13 August 1979 - 27 September 1984 (NODC Accession 9500016)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Columbia River estuary - Washington/Oregon from August 13, 1979 to September 27, 1984. Data...

  1. Current meter and other data collected using current meter in the NW Atlantic (limit-40 W) from ENDEAVOR and other platforms from 16 September 1980 to 12 May 1983 (NODC Accession 8600198)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter and other data were collected using current meter (PCM) casts from G. B. KELEZ, ENDEAVOR, and CAPE HATTERAS in the Northwest Atlantic Ocean. Data were...

  2. Current meter data from moored current meter casts in the Coastal Waters of Hawaii as part of the Ocean Thermal Energy Conversion (OTEC) project from 1980-09-23 to 1980-12-01 (NODC Accession 8100469)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Coastal Waters of Hawaii from September 23, 1980 to December 1, 1980. Data were submitted...

  3. Current meter data from moored current meter casts in the Puget Sound as part of the Mesa Puget Sound/PSERP project, 16 September 1975 - 01 April 1976 (NODC Accession 7601229)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Puget Sound from September 16, 1975 to April 1, 1976. Data were submitted by Pacific Marine...

  4. Current meter data from moored current meter casts in the Northwest Atlantic Ocean (limit -40 W) as part of the Ocean Dumping project, 1990-05-24 to 1991-06-17 (NODC Accession 9300112)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Northwest Atlantic Ocean (limit -40 W) from May 24, 1990 to June 17, 1991. Data were...

  5. Current meter data from moored current meter casts in the Coastal Waters of Florida as part of the Florida Straits Physical Oceanography (FSPO) project from 23 November 1990 - 19 August 1991 (NODC Accession 9200237)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Coastal Waters of Florida from November 23, 1990 to August 19, 1991. Data were submitted by...

  6. Current meter data from moored current meter casts in the Caribbean Sea as part of the Ocean Thermal Energy Conversion (OTEC) project from 15 February 1979 - 01 February 1980 (NODC Accession 8100608)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Caribbean Sea from February 15, 1979 to February 1, 1980. Data were submitted by University...

  7. Current meter data from moored current meter casts in the Puget Sound as part of the Mesa Puget Sound/PSERP project, 25 February 1976 - 01 September 1977 (NODC Accession 7800051)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Puget Sound from February 25, 1976 to September 1, 1977. Data were submitted by Pacific...

  8. Current meter data from moored current meter casts and other instruments in the TOGA Area - Pacific Ocean (30 N to 30 S) from 1992-01-01 to 1993-02-17 (NODC Accession 9600019)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts and other instruments in the TOGA Area - Pacific Ocean (30 N to 30 S) from January 1, 1992 to...

  9. Current meter data from moored current meter casts and other instruments in the TOGA Area - Pacific Ocean (30 N to 30 S) from 1992-11-03 to 1992-12-05 (NODC Accession 9600018)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts and other instruments in the TOGA Area - Pacific Ocean (30 N to 30 S) from November 3, 1992 to...

  10. Current meter and pressure gauge data from moored current meter casts and other instruments in the Gulf of Alaska as part of the Fisheries-Oceanography Cooperative Investigations (FOCI) project, 23 May 1988 - 01 April 1989 (NODC Accession 9000054)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter and pressure gauge data were collected using moored current meter casts and other instruments in the Gulf of Alaska from May 23, 1988 to March 1, 1989....

  11. Current meter and pressure gauge data from moored current meter casts and other instruments in the Gulf of Alaska as part of the Fisheries-Oceanography Cooperative Investigations (FOCI) project, 26 April 1989 - 26 September 1989 (NODC Accession 9100068)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter and pressure gauge data were collected using moored current meter casts and other instruments in the Gulf of Alaska from April 22, 1989 to September...

  12. Current meter data from moored current meter casts in the North Atlantic Ocean as part of the Outer Continental Shelf - South Atlantic (OCS-South Atlantic) project from 15 March 1981- 01 October 1981 (NODC Accession 8100718)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the North Atlantic Ocean from March 15, 1981 to October 1, 1981. Data were submitted by Science...

  13. Current meter data from moored current meter casts in the North Atlantic Ocean as part of the High Energy Benthic Boundary Exp. (HEBBLE) project from 19 March 1983 - 01 August 1984 (NODC Accession 8900107)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the North Atlantic Ocean from March 19, 1983 to August 1, 1984. Data were submitted by Woods...

  14. Current meter data from moored current meter casts in the Northeast Pacific Ocean as part of the Ocean Prediction Through Observation Modeling and Analysis (OPTOMA) project, 26 September 1984 - 16 July 1985 (NODC Accession 9600075)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Northeast Pacific Ocean from September 26, 1984 to July 16, 1985. Data were submitted by...

  15. Current meter data from moored current meter casts in the Coastal Waters of Washington/Oregon as part of the Land-Margin Ecosystem Research (LEML) project, 06 May 1997 - 19 October 1997 (NODC Accession 9800193)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter data were collected using moored current meter casts in the Coastal Waters of Washington/Oregon from May 6, 1997 to October 19, 1997. Data were...

  16. Current meter and temperature profile data from current meter and buoy casts in the TOGA area of Pacific Ocean from 29 March 1991 to 24 December 1993 (NODC Accession 9900057)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current meter and temperature profile data were collected using current meter and buoy casts in the TOGA area of Pacific Ocean from 29 March 1991 to 24 December...

  17. Radio-controlled automatic gas meter-reading system; Releve automatique de compteur par radio

    Energy Technology Data Exchange (ETDEWEB)

    Yasui, M. [Osaka Gas Co., Ltd (Japan); Ishikawa, K.; Fujiwara, J. [Tokyo Gas Co., Ltd. (Japan); Ichihashi, T. [Toho Gas Co., Ltd. (Japan)

    2000-07-01

    In Japan, an automatic gas meter-reading system is in operation, also incorporating the functions of monitoring for abnormalities in gas use and remote-controlled emergency gas supply shutoff. This system has been realized by linking microcomputer-controlled gas meters(It's called 'Intelligent gas mater') equipped with automatic shutoff mechanism to the gas utility company operation center via communication lines. While the present system uses cable communication lines, we of Tokyo Gas Co., Ltd., Osaka Gas Co., Ltd. and Toho Gas Co., Ltd., have jointly developed a new system based on radio communication. This paper introduces this new system. While radio-controlled meter-reading systems are used in many countries around the world solely for automatic meter reading, our recently developed system is also capable of monitoring for abnormalities in gas use and remote-controlled emergency gas supply shutoff, thanks to its almost real-time two-way communication function. The new system can serve for a period of ten years without recharging. It is also characterized by its applicability as different systems according to purposes: 1) conventional automatic meter-reading system (terminal network control unit or T-NCU), 2) large-scale radio-controlled meter-reading system, and 3) portable terminal-type radio-controlled meter-reading system. (authors)

  18. Effect of second phase on single phase flow meters in steam quality measurement

    Directory of Open Access Journals (Sweden)

    M Pusayatanont

    2016-04-01

    Full Text Available This paper presents results from an investigation of the two phase flow, especially liquid ingas phase, in most mainly used flow meter in steam industry namely differential pressuremeter is investigated. As in general, a flowmeter is designed and employed to measure flowrate of single phase fluid. There are many types of meter available in the market characterizeby their working principles, installed conditions and measured fluid. All meters representtheir accuracies under the single phase flow condition. However, when they are working inunusual conditions especially under multiphase flow, most meters lose their accuraciessignificantly even there is small amount of second phase introduced into the system. Tounderstand the deteriorated performance of the meter under two phase flow, additional studyon the effect the second phase on the meter is required.The laboratory experiment is set up to simulate the wet steam by flowing compressed airin the 2 inch pipe. Water droplet is generated by pressurized water flowing through a nozzleand then spayed into the system in range of 25% maximum by mass fraction. The signal fromeach flowmeter is collected by digital computer and analyzed using FFT and power spectrumdensity. The results show that the presence of the second phase in the system causes highfrequency fluctuation and causes significant error on meter reading. Flow manufacturersalways add low-pass filter circuit to remove this high frequency signal, however, this papershows that the high frequency signal in specific region is useful as it can be use to estimatedthe percentage of the second phase in the main phase system.

  19. Securing Metering Infrastructure of Smart Grid: A Machine Learning and Localization Based Key Management Approach

    Directory of Open Access Journals (Sweden)

    Imtiaz Parvez

    2016-08-01

    Full Text Available In smart cities, advanced metering infrastructure (AMI of the smart grid facilitates automated metering, control and monitoring of power distribution by employing a wireless network. Due to this wireless nature of communication, there exist potential threats to the data privacy in AMI. Decoding the energy consumption reading, injecting false data/command signals and jamming the networks are some hazardous measures against this technology. Since a smart meter possesses limited memory and computational capability, AMI demands a light, but robust security scheme. In this paper, we propose a localization-based key management system for meter data encryption. Data are encrypted by the key associated with the coordinate of the meter and a random key index. The encryption keys are managed and distributed by a trusted third party (TTP. Localization of the meter is proposed by a method based on received signal strength (RSS using the maximum likelihood estimator (MLE. The received packets are decrypted at the control center with the key mapped with the key index and the meter’s coordinates. Additionally, we propose the k-nearest neighbors (kNN algorithm for node/meter authentication, capitalizing further on data transmission security. Finally, we evaluate the security strength of a data packet numerically for our method.

  20. Performance Analysis of Secure and Private Billing Protocols for Smart Metering

    Directory of Open Access Journals (Sweden)

    Tom Eccles

    2017-11-01

    Full Text Available Traditional utility metering is to be replaced by smart metering. Smart metering enables fine-grained utility consumption measurements. These fine-grained measurements raise privacy concerns due to the lifestyle information which can be inferred from the precise time at which utilities were consumed. This paper outlines and compares two privacy-respecting time of use billing protocols for smart metering and investigates their performance on a variety of hardware. These protocols protect the privacy of customers by never transmitting the fine-grained utility readings outside of the customer’s home network. One protocol favors complexity on the trusted smart meter hardware while the other uses homomorphic commitments to offload computation to a third device. Both protocols are designed to operate on top of existing cryptographic secure channel protocols in place on smart meters. Proof of concept software implementations of these protocols have been written and their suitability for real world application to low-performance smart meter hardware is discussed. These protocols may also have application to other privacy conscious aggregation systems, such as electronic voting.

  1. Intelligent meters in the Netherlands. Revised financial analysis and recommendations for policy; Intelligente meters in Nederland. Herziene financiele analyse en adviezen voor beleid

    Energy Technology Data Exchange (ETDEWEB)

    Van Gerwen, R.; Koenis, F.; Schrijner, M.; Widdershoven, G.

    2010-07-13

    Commissioned by the Dutch Ministry of Economic Affairs (EZ) a new cost-benefit analysis has been carried out on the national introduction of smart meters. The aim is to gain insight into the implications of changed circumstances. In 2005, KEMA carried out such a social cost-benefit analysis. Since then, several changes took place on a political, economic and technical level. [Dutch] In opdracht van het ministerie van Economische Zaken (EZ) is een nieuwe kosten-batenanalyse uitgevoerd naar de landelijke invoering van de intelligente meter. Dit om inzicht te krijgen in de gevolgen van de veranderde omstandigheden. In 2005 voerde KEMA, in opdracht van EZ, een maatschappelijke kosten-batenanalyse uit naar de invoering van de intelligente meter. Sindsdien is er op politiek, economisch en technisch vlak het nodige veranderd.

  2. Development and evaluation of a meter for measuring return line fluid flow rates during drilling

    Energy Technology Data Exchange (ETDEWEB)

    Loeppke, G.E.; Schafer, D.M.; Glowka, D.A.; Scott, D.D.; Wernig, M.D. (Sandia National Labs., Albuquerque, NM (United States)); Wright, E.K. (Ktech Corp., Albuquerque, NM (United States))

    1992-06-01

    The most costly problem routinely encountered in geothermal drilling is lost circulation, which occurs when drilling fluid is lost to the formation rather than circulating back to the surface. The successful and economical treatment of lost circulation requires the accurate measurement of drilling fluid flow rate both into and out of the well. This report documents the development of a meter for measuring drilling fluid outflow rates in the return line of a drilling rig. The meter employs a rolling counterbalanced float that rides on the surface of the fluid in the return line. The angle of the float pivot arm is sensed with a pendulum potentiometer, and the height of the float is calculated from this measurement. The float height is closely related to the fluid height and, therefore, the flow rate in the line. The prototype rolling float meter was extensively tested under laboratory conditions in the Wellbore Hydraulics Flow Facility; results from these tests were used in the design of the field prototype rolling float meter. The field prototype meter was tested under actual drilling conditions in August and September 1991 at the Long Valley Exploratory Well near Mammoth Lakes, Ca. In addition, the performance of several other commercially available inflow and outflow meters was evaluated in the field. The tested inflow meters included conventional pump stroke counters, rotary pump speed counters, magnetic flowmeters, and an ultrasonic Doppler flowmeter. On the return flow line, a standard paddlemeter, an acoustic level meter, and the prototype rolling float meter were evaluated for measuring drilling fluid outflow rates.

  3. Calibration of Soil Moisture Measurement Using Pr2 Moisture Meter and Gravimetric-Based Approaches

    Directory of Open Access Journals (Sweden)

    Olotu Yahaya

    2016-10-01

    Full Text Available The research study strongly focused on creating strong mechanism for measuring and evaluating soil moisture content comparing PR2 capacitance moisture meter and gravimetric approach. PR2 moisture meter shows a better performance accuracy of ± 6%; 0.06 m 3 /m 3 and intercept a0 =1.8; indicating the field is heavy clay. It measures to 1000 mm depth with high precision; while realistic result could not be obtained from gravimetric method at this measuring depth. Therefore, effective soil moisture measuring, monitoring and evaluation can be achieved with PR2 moisture meter.

  4. Instrument Qualification of Custom Fabricated Water Activity Meter for Hot Cell Use

    Energy Technology Data Exchange (ETDEWEB)

    McCoskey, Jacob K. [Hanford Site (HNF), Richland, WA (United States)

    2014-01-22

    This report describes a custom fabricated water activity meter and the results of the qualification of this meter as described in the laboratory test plan LAB-PLN-11-00012, Testing and Validation of an Enhanced Acquisition and Control System. It was calibrated against several NaOH solutions of varying concentrations to quantify the accuracy and precision of the instrument at 20 °C and 60 °C. Also, a schematic and parts list of the equipment used to make the water activity meter will be presented in this report.

  5. Effect of Budesonide by metered dose inhaler with or without spacer & dry powder inhaler on Lung Function

    OpenAIRE

    Dilshad Ali Rizvi; Mohammad Tariq Salman; Joydeep Sircar; Ali Ahmad

    2013-01-01

    Aims & objective-To compare the efficacy of Budesonide delivered by metered dose inhaler, metered dose inhaler with spacer and dry powder inhaler on the lung function test parameters. Materials and Methods: This prospective study was undertaken to assess the effect of budesonide administered from fifty patients of chronic stable bronchial asthma were budesonide(400mcg) by metered dose inhaler, metered dose inhaler with spacer and by dry powder inhaler at day 14, 21 and 28 after enrolment ...

  6. The NASA Meter Class Autonomous Telescope: Ascension Island

    Science.gov (United States)

    Lederer, S.; Stansbery, E. G.; Cowardin, H. M.; Kervin, P.; Hickson, P.

    2013-09-01

    The Meter Class Autonomous Telescope (MCAT) is the newest optical sensor dedicated to NASA's mission to characterize the space debris environment. It is the successor to a series of optical telescopes developed and operated by the JSC Orbital Debris Program Office (ODPO) to monitor and assess the debris environment in (1) Low Earth Orbit (LEO), (2) Medium Earth Orbit (MEO), and (3) Geosynchronous Orbit (GEO), with emphasis on LEO and GEO altitudes. A joint NASA-Air Force Research Labs project, MCAT is a 1.3m optical telescope dedicated to debris research. Its optical path and sensor yield a large survey fence at the cutting edge of current detector performance. It has four primary operational observing modes, two of which were not computationally feasible a decade ago. Operations are supported by a sophisticated software suite that monitors clouds and weather conditions, and controls everything from data collection to dome rotation to processing tens of GB of imagery data nightly. With fainter detection limits, precision detection, acquisition and tracking of targets, multi-color photometry, precision astrometry, automated re-acquisition capability, and the ability to process all data at the acquisition rate, MCAT is capable of producing and processing a volume and quality of data far in excess of any current (or prior) ODPO operations. This means higher fidelity population inputs and eliminating the multi-year backlog from acquisition-to-product typical of optical campaigns. All of this is possible given a suitable observing location. Originally planned for the island of Legan, part of the Kwajalein Atoll Islands, recent developments have led to a change in venue. Specifically, the Ground-based Electro-Optical Deep Space Surveillance, or GEODSS, System of telescopes is the United States' major tracking system for deep space. This network consists of telescopes in Maui, Hawaii; Diego Garcia (Indian Ocean), and Socorro, New Mexico. A fourth optical telescope, though

  7. 49 CFR 228.103 - Approval procedure: construction within one-half mile (2,640 feet) (804 meters).

    Science.gov (United States)

    2010-10-01

    ... mile (2,640 feet) (804 meters). 228.103 Section 228.103 Transportation Other Regulations Relating to... within one-half mile (2,640 feet) (804 meters). (a) A common carrier that has developed plans for the... less than one-half mile (2,640 feet) (804 meters) from any area where switching or humping operations...

  8. USGS Small-scale Dataset - 100-Meter Resolution Satellite View of Hawaii 201304 GeoTIFF

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Satellite View of Hawaii map layer is a 100-meter resolution simulated natural-color image of Hawaii. Vegetation is generally green, with forests in darker green...

  9. 100-Meter Resolution Satellite View of the Conterminous United States - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Satellite View of the Conterminous United States map layer is a 100-meter resolution simulated natural-color image of the United States. Vegetation is generally...

  10. Design and Fabrication of a Soil Moisture Meter Using Thermal Conductivity Properties of Soil

    National Research Council Canada - National Science Library

    Subir Das; Biplab Bag; T S Sarkar; Nisher Ahmed; B Chakrabrty

    2011-01-01

    ... of soil moisture modeling. In this present work design of a soil moisture measurement meter using thermal conductivity properties of soil has been proposed and experimental results are reported...

  11. Structured Literature Review of Electricity Consumption Classification Using Smart Meter Data

    National Research Council Canada - National Science Library

    Alexander Martin Tureczek; Per Sieverts Nielsen

    2017-01-01

    .... This paper applies a modification of Okoli’s method for conducting structured literature reviews to generate an overview of research in electricity customer classification using smart meter data...

  12. EnviroAtlas - Phoenix, AZ - Meter-Scale Urban Land Cover (MULC) Data (2010)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EnviroAtlas Phoenix, AZ Meter-Scale Urban Land Cover (MULC) data and map were generated from USDA NAIP (National Agricultural Imagery Program) four band (red,...

  13. USGS Small-scale Dataset - 100-Meter Resolution Satellite View of Alaska 201304 GeoTIFF

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Satellite View of Alaska map layer is a 100-meter resolution simulated natural-color image of Alaska. Vegetation is generally green, with forests in darker green...

  14. Structured Literature Review of Electricity Consumption Classification Using Smart Meter Data

    DEFF Research Database (Denmark)

    Tureczek, Alexander Martin; Nielsen, Per Sieverts

    2017-01-01

    Smart meters for measuring electricity consumption are fast becoming prevalent in households. The meters measure consumption on a very fine scale, usually on a 15 min basis, and the data give unprecedented granularity of consumption patterns at household level. A multitude of papers have emerged...... utilizing smart meter data for deepening our knowledge of consumption patterns. This paper applies a modification of Okoli's method for conducting structured literature reviews to generate an overview of research in electricity customer classification using smart meter data. The process assessed 2099 papers...... before identifying 34 significant papers, and highlights three key points: prominent methods, datasets and application. Three important findings are outlined. First, only a few papers contemplate future applications of the classification, rendering papers relevant only in a classification setting. Second...

  15. Nissan North America: How Sub-Metering Changed the Way a Plant Does Business

    Energy Technology Data Exchange (ETDEWEB)

    None

    2011-06-30

    Case study - For Nissan, sub-metering data now drives decision-making and has empowered plant staff, helped senior leadership understand the bottom-line impact of proposed projects, and produced meaningful energy savings.

  16. 100-Meter Resolution Grayscale Shaded Relief of the Conterminous United States - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Grayscale Shaded Relief of the Conterminous United States map layer is a 100-meter resolution grayscale shaded relief image of the United States, in an Albers...

  17. EnviroAtlas -- Virginia Beach/Williamsburg, VA -- Meter-Scale Urban Land Cover (MULC)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Virginia Beach, VA EnviroAtlas Meter-scale Urban Land Cover (MULC) dataset comprises 3,724 km2 of southeast Virginia and includes Hampton, Newport News, Suffolk,...

  18. USGS Small-scale Dataset - Color Hawaii Shaded Relief - 200-Meter Resolution 200512 GeoTIFF

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The color Hawaii shaded relief data were derived from National Elevation Dataset (NED) data, and show the terrain of Hawaii at a resolution of 200 meters. The NED is...

  19. 100-Meter Resolution Tree Canopy of the Conterminous United States - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer contains tree canopy data for the conterminous United States, in an Albers Equal-Area Conic projection and at a resolution of 100 meters. The tree...

  20. 100-Meter Resolution Land/Water Mask of Alaska - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This Land/Water Mask is a 100-meter resolution image of Alaska, with separate values for oceans and for land areas of the United States, Canada, and Russia.

  1. Mental abilities and performance efficacy under a simulated 480 meters helium-oxygen saturation diving

    Directory of Open Access Journals (Sweden)

    gonglin ehou

    2015-07-01

    Full Text Available Stress in extreme environment severely disrupts human physiology and mental abilities. The present study investigated the cognition and performance efficacy of four divers during a simulated 480 meters helium-oxygen saturation diving. We analyzed the spatial memory, 2D/3D mental rotation functioning, grip strength, and hand-eye coordination ability in four divers during the 0 – 480 meters compression and decompression processes of the simulated diving. The results showed that except for its mild decrease on grip strength, the high atmosphere pressure condition significantly impaired the hand-eye coordination (especially at 300 meters, the reaction time and correct rate of mental rotation, as well as the spatial memory (especially as 410 meters, showing high individual variability. We conclude that the human cognition and performance efficacy are significantly affected during deep water saturation diving.

  2. High Mountain Asia 8-meter DEMs Derived from Along-track Optical Imagery V001

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains 8-meter Digital Elevation Models (DEMs) of high mountain Asia glacier and snow regions generated from very-high-resolution commercial...

  3. 100-Meter Resolution Impervious Surface of the Conterminous United States - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer contains impervious surface data for the conterminous United States, in an Albers Equal-Area Conic projection and at a resolution of 100 meters. The...

  4. EnviroAtlas - New Bedford, MA - Meter-Scale Urban Land Cover (MULC) Data (2010)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The New Bedford, MA Meter-Scale Urban Land Cover (MULC) data were generated from United States Department of Agriculture (USDA) National Agricultural Imagery Program...

  5. EnviroAtlas - Memphis, TN - Meter-Scale Urban Land Cover (MULC) Data (2012)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Memphis, TN EnviroAtlas One Meter-scale Urban Land Cover (MULC) dataset comprises 2,733 km2 around the city of Memphis, surrounding towns, and rural areas. These...

  6. EnviroAtlas - Pittsburgh, PA - Meter-Scale Urban Land Cover (MULC) Data (2010)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EnviroAtlas Pittsburgh, PA Meter-Scale Urban Land Cover (MULC) data was generated from United States Department of Agriculture (USDA) National Agricultural...

  7. EnviroAtlas - Portland, ME - Meter-Scale Urban Land Cover (MULC) Data (2010)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EnviroAtlas Portland, ME Meter-Scale Urban Land Cover (MULC) data was generated from USDA NAIP (National Agricultural Imagery Program) four band (red, green,...

  8. EnviroAtlas - Fresno, CA - Meter-Scale Urban Land Cover (MULC) Data (2010)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Fresno, CA EnviroAtlas Meter-Scale Urban Land Cover (MULC) Data were generated via supervised classification of combined aerial photography and LiDAR data. The...

  9. EnviroAtlas - Austin, TX - Meter-Scale Urban Land Cover (MULC) Data (2010)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Austin, TX EnviroAtlas One Meter-scale Urban Land Cover (MULC) Data were generated from United States Department of Agriculture (USDA) National Agricultural...

  10. Generation of a Near Infra-Red Guide Star Catalog for Thirty-Meter ...

    Indian Academy of Sciences (India)

    IRGSC) for Thirty Meter Telescope (TMT) observations are identified and presented. ... Energy Distribution (SED) template fitting for optimal classification of stars in the fainter end, incorporating spectral libraries in the model, to reduce the scatter, ...

  11. The sensory power of cameras and noise meters for protest surveillance in South Korea.

    Science.gov (United States)

    Kim, Eun-Sung

    2016-06-01

    This article analyzes sensory aspects of material politics in social movements, focusing on two police tools: evidence-collecting cameras and noise meters for protest surveillance. Through interviews with Korean political activists, this article examines the relationship between power and the senses in the material culture of Korean protests and asks why cameras and noise meters appeared in order to control contemporary peaceful protests in the 2000s. The use of cameras and noise meters in contemporary peaceful protests evidences the exercise of what Michel Foucault calls 'micro-power'. Building on material culture studies, this article also compares the visual power of cameras with the sonic power of noise meters, in terms of a wide variety of issues: the control of things versus words, impacts on protest size, differential effects on organizers and participants, and differences in timing regarding surveillance and punishment.

  12. EnviroAtlas - Tampa, FL - Meter-Scale Urban Land Cover (MULC) Data (2010)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EnviroAtlas Tampa, FL Meter-Scale Urban Land Cover (MULC) data was generated from USDA NAIP (National Agricultural Imagery Program) four band (red, green, blue...

  13. EnviroAtlas - Durham, NC - Meter-Scale Urban Land Cover (MULC) Data (2010)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EnviroAtlas Durham, NC Meter-Scale Urban Land Cover (MULC) data was generated from USDA NAIP (National Agricultural Imagery Program) four band (red, green, blue...

  14. Now that we have smart meters, what do we do with them?

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-01-15

    For years, electric utilities have been dreaming about the day when they would have smart meters on customers' premises. However, there have always been lingering doubts among some consumer advocates and critics of the smart metering schemes about their cost-effectiveness. An issue that is beginning to become noticed is that installing smart meters and introducing variable pricing will accomplish very little unless the price signals are communicated to consumers and -- more important -- to energy-using devices beyond the meter. Since consumers are unlikely to sit around watching variable prices and adjusting consumption or thermostat settings, ways must be found for the price signals to automatically and directly communicate with devices,.

  15. Stellwagen Bank bathymetry - Degree slope derived from 5-meter bathymetric contour lines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Degree slope of Stellwagen Bank bathymetry. Raster derived from 5-meter bathymetric contour lines (Quads 1-18). Collected on surveys carried out in 4 cruises 1994 -...

  16. Stellwagen Bank bathymetry - Percent slope derived from 5-meter bathymetric contour lines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Percent slope of Stellwagen Bank bathymetry. Raster derived from 5-meter bathymetric contour lines (Quads 1-18). Collected on surveys carried out in 4 cruises 1994 -...

  17. Tilt meters for the Alignment System of the CMS Experiment: Users Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Alberdi, J.; Arce, P.; Barcala, J.M.; Calvo, E.; Ferrando, A.; Josa, M.I.; Molinero, A.; Navarrete, J.; Oller, J.C.; Yuste, C.

    2007-09-27

    We present the instructions for the use of the electrolytic tilt meters installed in the link alignments system of the CMS experimental and give the Data Base to be used as a Handbook during CMS operation. (Author) 16 refs.

  18. Enhanced Operation of Electricity Distribution Grids Through Smart Metering PLC Network Monitoring, Analysis and Grid Conditioning

    Directory of Open Access Journals (Sweden)

    Iker Urrutia

    2013-01-01

    Full Text Available Low Voltage (LV electricity distribution grid operations can be improved through a combination of new smart metering systems’ capabilities based on real time Power Line Communications (PLC and LV grid topology mapping. This paper presents two novel contributions. The first one is a new methodology developed for smart metering PLC network monitoring and analysis. It can be used to obtain relevant information from the grid, thus adding value to existing smart metering deployments and facilitating utility operational activities. A second contribution describes grid conditioning used to obtain LV feeder and phase identification of all connected smart electric meters. Real time availability of such information may help utilities with grid planning, fault location and a more accurate point of supply management.

  19. EnviroAtlas - Cleveland, OH - Meter-Scale Urban Land Cover (MULC) Data (2011 and 2013)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Cleveland, OH EnviroAtlas Meter-scale Urban Land Cover (MULC) dataset comprises 2,737 km2 around the city of Cleveland and portions of surrounding counties. The...

  20. EnviroAtlas - Green Bay, WI - Meter-Scale Urban Land Cover (MULC) Data (2010)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Green Bay, WI Meter-Scale Urban Land Cover (MULC) dataset comprises 936 km2 around the city of Green Bay, surrounding towns, tribal lands and rural areas in...

  1. Compact Mass Flow Meter Based on a Micro Coriolis Flow Sensor

    Directory of Open Access Journals (Sweden)

    Remco Wiegerink

    2013-03-01

    Full Text Available In this paper we demonstrate a compact ready-to-use micro Coriolis mass flow meter. The full scale flow is 1 g/h (for water at a pressure drop < 1 bar. It has a zero stability of 2 mg/h and an accuracy of 0.5% reading for both liquids and gases. The temperature drift between 10 and 50 °C is below 1 mg/h/°C. The meter is robust, has standard fluidic connections and can be read out by means of a PC or laptop via USB. Its performance was tested for several common gases (hydrogen, helium, nitrogen, argon and air and liquids (water and isopropanol. As in all Coriolis mass flow meters, the meter is also able to measure the actual density of the medium flowing through the tube. The sensitivity of the measured density is ~1 Hz.m3/kg.

  2. EnviroAtlas - Milwaukee, WI - Meter-Scale Urban Land Cover Data (MULC) Data (2010)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EnviroAtlas Milwaukee, WI Meter Urban Land Cover (MULC) data and map were generated from USDA NAIP (National Agricultural Imagery Program) four band (red, green,...

  3. EnviroAtlas - New Haven, CT - Meter-Scale Urban Land Cover Data (2014)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EnviroAtlas New Haven, CT EnviroAtlas Meter-scale Urban Land Cover (MULC) Data were generated from United States Department of Agriculture (USDA) National...

  4. EnviroAtlas - Woodbine, IA - Meter-Scale Urban Land Cover (MULC) Data (2011)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EnviroAtlas Woodbine, IA Meter-Scale Urban Land Cover (MULC) data and map were generated from USDA NAIP (National Agricultural Imagery Program) four band (red,...

  5. 100-Meter Resolution Land/Water Mask of the Conterminous United States - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This Land/Water Mask is a 100-meter resolution image of the conterminous United States, with separate values for oceans and for land areas of the United States,...

  6. EnviroAtlas - New York, NY - Meter-Scale Urban Land Cover (MULC) Data (2008)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The New York, NY EnviroAtlas Meter-scale Urban Land Cover (MULC) Data were generated by the University of Vermont Spatial Analysis Laboratory (SAL) under the...

  7. EnviroAtlas - Portland, OR - Meter-Scale Urban Land Cover (MULC) Data (2012)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EnviroAtlas Portland, OR Meter-Scale Urban Land Cover (MULC) dataset includes data for the Portland metropolitan area plus the city of Vancouver, Washington and...

  8. EnviroAtlas - Des Moines, IA - Meter-Scale Urban Land Cover (MULC) Data (2010)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Des Moines, IA EnviroAtlas Meter-Scale Urban Land Cover (MULC) Data were generated from the High Resolution Land Cover (HRLC) product created by the Iowa...

  9. VT 20 ft Contour Lines generated from 10 meter NED DEM

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) This dataset is derived from the multi-resolution National Elevation Dataset (NED), at resolutions of both 1/3 arc-second (approx. 10 meters) and...

  10. Color Alaska Shaded Relief ? 200-Meter Resolution, Albers projection - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The color Alaska shaded relief data were derived from National Elevation Dataset (NED) data, and show the terrain of Alaska at a resolution of 200 meters. The NED is...

  11. 100-Meter Resolution Satellite View with Shaded Relief of Hawaii - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Satellite View with Shaded Relief of Hawaii map layer is a 100-meter resolution simulated natural-color image of Hawaii, with relief shading added to accentuate...

  12. USGS Small-scale Dataset - 100-Meter Resolution Color-Sliced Elevation of Alaska 201303 TIFF

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The map layer of Color-Sliced Elevation of Alaska is a 100-meter resolution elevation image of Alaska, in an Albers Equal-Area Conic projection. Each color tint...

  13. 100-Meter Resolution Color Shaded Relief of the Conterminous United States - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Color Shaded Relief of the Conterminous United States map layer is a 100-meter resolution color-sliced elevation image of the United States, with relief shading...

  14. USGS Small-scale Dataset - Color Alaska Shaded Relief - 200-Meter Resolution 200512 GeoTIFF

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The color Alaska shaded relief data were derived from National Elevation Dataset (NED) data, and show the terrain of Alaska at a resolution of 200 meters. The NED is...

  15. USGS Small-scale Dataset - 100-Meter Resolution Color-Sliced Elevation of Hawaii 201303 TIFF

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The map layer of Color-Sliced Elevation of Hawaii is a 100-meter resolution elevation image of Hawaii, in an Albers Equal-Area Conic projection. Each color tint...

  16. 100-Meter Resolution Color-Sliced Elevation of Hawaii - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The map layer of Color-Sliced Elevation of Hawaii is a 100-meter resolution elevation image of Hawaii, in an Albers Equal-Area Conic projection. Each color tint...

  17. 100-Meter Resolution Color-Sliced Elevation of the Conterminous United States - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The map layer of Color-Sliced Elevation of the Conterminous United States is a 100-meter resolution elevation image of the United States, in an Albers Equal-Area...

  18. Color Hawaii Shaded Relief ? 200-Meter Resolution, Albers projection - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The color Hawaii shaded relief data were derived from National Elevation Dataset (NED) data, and show the terrain of Hawaii at a resolution of 200 meters. The NED is...

  19. Dance and Music in "Gangnam Style": How Dance Observation Affects Meter Perception: e0134725

    National Research Council Canada - National Science Library

    Kyung Myun Lee; Karen Chan Barrett; Yeonhwa Kim; Yeoeun Lim; Kyogu Lee

    2015-01-01

    .... This study investigated how the viewing of dance motions shapes sound perception. Previous research has shown that dance reflects the temporal structure of its accompanying music, communicating musical meter (i.e...

  20. SYNTHESIS OF ARTIFICIAL GRAVITATIONAL FIELDS VIRTUAL METERS FOR THE POLYCONFLICTS RESOLUTION IN THE AERONAVIGATION ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    Valery Chepizhenko

    2012-09-01

    Full Text Available  In article schemes have been offered and characteristics of virtual meters of artificial force fields for the conflicts resolution in the aeronavigation environment have been investigated.

  1. Design and implementation of Remote Digital Energy Meter (RDEM) based on GSM technology

    Science.gov (United States)

    Khan, Muhammad Waseem; Wang, Jie; Irfan, Muhammad; Shiraz, M.; Khan, Ali Hassan

    2017-11-01

    Electric power is one of the basic requirement for socio economic and social prosperity of any country, which is mainly employs for domestic, industrial and agricultural sectors. The primary purpose of this research is to design and implement an energy meter which can remotely control and monitor through global system for mobile (GSM) communication technology. For this purpose, a single phase or three phase digital energy meters are used to add on different advanced modules. The energy meter can be activated and display power consumption information at the consumer premises on liquid crystal display and through a short message service (SMS) by using GSM technology. At the power sending end, an energy meter can be remotely control and monitor through GSM technology without any system disturbances. This study will lead to make the system easier, economical, reliable and efficient for the electrical department.

  2. IceBridge ZLS Dynamic Gravity Meter Time-Registered L1B Vertical Accelerations

    Data.gov (United States)

    National Aeronautics and Space Administration — The IceBridge ZLS Dynamic Gravity Meter Time-Registered L1B Vertical Accelerations (IGZLS1B) data set contains vertical, cross body, and along body acceleration...

  3. QuaMeter: multivendor performance metrics for LC-MS/MS proteomics instrumentation.

    Science.gov (United States)

    Ma, Ze-Qiang; Polzin, Kenneth O; Dasari, Surendra; Chambers, Matthew C; Schilling, Birgit; Gibson, Bradford W; Tran, Bao Q; Vega-Montoto, Lorenzo; Liebler, Daniel C; Tabb, David L

    2012-07-17

    LC-MS/MS-based proteomics studies rely on stable analytical system performance that can be evaluated by objective criteria. The National Institute of Standards and Technology (NIST) introduced the MSQC software to compute diverse metrics from experimental LC-MS/MS data, enabling quality analysis and quality control (QA/QC) of proteomics instrumentation. In practice, however, several attributes of the MSQC software prevent its use for routine instrument monitoring. Here, we present QuaMeter, an open-source tool that improves MSQC in several aspects. QuaMeter can directly read raw data from instruments manufactured by different vendors. The software can work with a wide variety of peptide identification software for improved reliability and flexibility. Finally, QC metrics implemented in QuaMeter are rigorously defined and tested. The source code and binary versions of QuaMeter are available under Apache 2.0 License at http://fenchurch.mc.vanderbilt.edu.

  4. EnviroAtlas - Paterson, NJ - Meter-Scale Urban Land Cover (MULC) Data (2010)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Paterson, New Jersey EnviroAtlas Meter-Scale Urban Land Cover (MULC) data comprises approximately 66 km2 around the city of Paterson. The land cover data were...

  5. CRED 1 meter resolution Reson 8101 multibeam backscatter data of Wake Island, West Central Pacific, 2007.

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Multibeam backscatter imagery extracted from gridded bathymetry of Wake Island, West Central Pacific.These data provide coverage between 0 and 200m meters. The...

  6. How Down is a Downbeat? Feeling Meter and Gravity in Music and Dance

    Directory of Open Access Journals (Sweden)

    Jonathan Still

    2015-09-01

    Full Text Available The idea that metrical accent might be related to an embodied sense of "up" and "down" is implied by the terms "upbeat" and "downbeat," and is central to theories of meter as gravitational field, such as those evolved by Robert Hatten and Steve Larson. Yet as Hatten himself notes, upbeats and downbeats do not always map conveniently on to upward or downward movements in dance. Drawing on ethnographic research among trainee ballet teachers and recent theories of musical meter, this article discusses some practical and theoretical problems that arise when trying to teach about meter in the context of ballet training. It is suggested that empathic listening and perspective taking, rather than appeals to common embodied experiences of meter, may be key to developing better interdisciplinary understanding between musicians and dancers.

  7. EnviroAtlas - Paterson, NJ - One Meter Resolution Urban Land Cover (2010) Web Service

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Paterson, New Jersey EnviroAtlas One Meter-scale Urban Land Cover Web Service comprises approximately 66 km2 around the city of Paterson. The land cover data...

  8. Design and Construction of a New 1420 MHz Receiver System for a 12-meter Radio Telescope

    Science.gov (United States)

    Lemley, Cameron; Castelaz, M. W.

    2014-01-01

    During the summer of 2013, a new 1420 MHz receiver system was designed and constructed for the 12-meter radio telescope at the Pisgah Astronomical Research Institute (PARI). The new radio receiver system consists of a feedhorn (which is a duplicate of the feedhorn that is currently installed on PARI’s 4.6-meter radio telescope), a low-noise amplifier, a bandpass filter, a downconverter, a SpectraCyber 1420 MHz Hydrogen Line Spectrometer, CommScope CNT-600 braided coaxial cable, and a power supply. Each component was individually tested on the preexisting 4.6-meter radio telescope receiver system before being installed on the 12-meter telescope. This testing process revealed that the spectrometer that was intended for use in the new 12-meter receiver system would require 12-bit software, which was acquired soon thereafter. The new receiver system was then assembled on a rolling cart for further testing. After the 1420 MHz receiver system was moved outside, it successfully detected its first extraterrestrial radio signal. The next step of this project was the installation of the feedhorn at the focus of the 12-meter parabolic reflector and the mounting of the additional receiver system components inside the radio frequency (RF) room of the 12-meter telescope. Following its installation on the 12-meter telescope, the new receiver system was connected to the PARI network via ethernet using a device called a SitePlayer Telnet. The 12-meter telescope was focused by taking continuum scans of Virgo A during its meridian crossing. The positioning of the feedhorn had to be adjusted several times before the new radio receiver system was precisely focused. After focusing the 12-meter telescope, spectra were taken of both the Orion Nebula and the Crab Nebula to test the abilities of the new 1420 MHz receiver system. As a final test of both the angular resolution and time resolution of the new radio receiver system, the 12-meter telescope was used to observe the pulsar PSR J

  9. Dance and Music in "Gangnam Style": How Dance Observation Affects Meter Perception.

    Science.gov (United States)

    Lee, Kyung Myun; Barrett, Karen Chan; Kim, Yeonhwa; Lim, Yeoeun; Lee, Kyogu

    2015-01-01

    Dance and music often co-occur as evidenced when viewing choreographed dances or singers moving while performing. This study investigated how the viewing of dance motions shapes sound perception. Previous research has shown that dance reflects the temporal structure of its accompanying music, communicating musical meter (i.e. a hierarchical organization of beats) via coordinated movement patterns that indicate where strong and weak beats occur. Experiments here investigated the effects of dance cues on meter perception, hypothesizing that dance could embody the musical meter, thereby shaping participant reaction times (RTs) to sound targets occurring at different metrical positions.In experiment 1, participants viewed a video with dance choreography indicating 4/4 meter (dance condition) or a series of color changes repeated in sequences of four to indicate 4/4 meter (picture condition). A sound track accompanied these videos and participants reacted to timbre targets at different metrical positions. Participants had the slowest RT's at the strongest beats in the dance condition only. In experiment 2, participants viewed the choreography of the horse-riding dance from Psy's "Gangnam Style" in order to examine how a familiar dance might affect meter perception. Moreover, participants in this experiment were divided into a group with experience dancing this choreography and a group without experience. Results again showed slower RTs to stronger metrical positions and the group with experience demonstrated a more refined perception of metrical hierarchy. Results likely stem from the temporally selective division of attention between auditory and visual domains. This study has implications for understanding: 1) the impact of splitting attention among different sensory modalities, and 2) the impact of embodiment, on perception of musical meter. Viewing dance may interfere with sound processing, particularly at critical metrical positions, but embodied familiarity with

  10. Dance and Music in “Gangnam Style”: How Dance Observation Affects Meter Perception

    Science.gov (United States)

    Lee, Kyung Myun; Barrett, Karen Chan; Kim, Yeonhwa; Lim, Yeoeun; Lee, Kyogu

    2015-01-01

    Dance and music often co-occur as evidenced when viewing choreographed dances or singers moving while performing. This study investigated how the viewing of dance motions shapes sound perception. Previous research has shown that dance reflects the temporal structure of its accompanying music, communicating musical meter (i.e. a hierarchical organization of beats) via coordinated movement patterns that indicate where strong and weak beats occur. Experiments here investigated the effects of dance cues on meter perception, hypothesizing that dance could embody the musical meter, thereby shaping participant reaction times (RTs) to sound targets occurring at different metrical positions.In experiment 1, participants viewed a video with dance choreography indicating 4/4 meter (dance condition) or a series of color changes repeated in sequences of four to indicate 4/4 meter (picture condition). A sound track accompanied these videos and participants reacted to timbre targets at different metrical positions. Participants had the slowest RT’s at the strongest beats in the dance condition only. In experiment 2, participants viewed the choreography of the horse-riding dance from Psy’s “Gangnam Style” in order to examine how a familiar dance might affect meter perception. Moreover, participants in this experiment were divided into a group with experience dancing this choreography and a group without experience. Results again showed slower RTs to stronger metrical positions and the group with experience demonstrated a more refined perception of metrical hierarchy. Results likely stem from the temporally selective division of attention between auditory and visual domains. This study has implications for understanding: 1) the impact of splitting attention among different sensory modalities, and 2) the impact of embodiment, on perception of musical meter. Viewing dance may interfere with sound processing, particularly at critical metrical positions, but embodied

  11. A Dedicated Mixture Model for Clustering Smart Meter Data: Identification and Analysis of Electricity Consumption Behaviors

    OpenAIRE

    Fateh Nassim Melzi; Allou Same; Mohamed Haykel Zayani; Latifa Oukhellou

    2017-01-01

    The large amount of data collected by smart meters is a valuable resource that can be used to better understand consumer behavior and optimize electricity consumption in cities. This paper presents an unsupervised classification approach for extracting typical consumption patterns from data generated by smart electric meters. The proposed approach is based on a constrained Gaussian mixture model whose parameters vary according to the day type (weekday, Saturday or Sunday). The proposed method...

  12. Design And Construction Of Digital Multi-Meter Using PIC Microcontroller

    OpenAIRE

    Khawn Nue; Dr. KyawSoe Lwin; Hla Myo Tun

    2015-01-01

    Abstract This thesis describes the design and construction of digital multi-meter using PIC microcontroller. In this system a typical multi-meter may include features such as the ability to measure ACDC voltage DC current resistance temperature diodes frequency and connectivity. This design uses of the PIC microcontroller voltage rectifiers voltage divide potentiometer LCD and other instruments to complete the measure. When we used what we have learned of microprocessors and adjust the progra...

  13. Dance and Music in "Gangnam Style": How Dance Observation Affects Meter Perception.

    Directory of Open Access Journals (Sweden)

    Kyung Myun Lee

    Full Text Available Dance and music often co-occur as evidenced when viewing choreographed dances or singers moving while performing. This study investigated how the viewing of dance motions shapes sound perception. Previous research has shown that dance reflects the temporal structure of its accompanying music, communicating musical meter (i.e. a hierarchical organization of beats via coordinated movement patterns that indicate where strong and weak beats occur. Experiments here investigated the effects of dance cues on meter perception, hypothesizing that dance could embody the musical meter, thereby shaping participant reaction times (RTs to sound targets occurring at different metrical positions.In experiment 1, participants viewed a video with dance choreography indicating 4/4 meter (dance condition or a series of color changes repeated in sequences of four to indicate 4/4 meter (picture condition. A sound track accompanied these videos and participants reacted to timbre targets at different metrical positions. Participants had the slowest RT's at the strongest beats in the dance condition only. In experiment 2, participants viewed the choreography of the horse-riding dance from Psy's "Gangnam Style" in order to examine how a familiar dance might affect meter perception. Moreover, participants in this experiment were divided into a group with experience dancing this choreography and a group without experience. Results again showed slower RTs to stronger metrical positions and the group with experience demonstrated a more refined perception of metrical hierarchy. Results likely stem from the temporally selective division of attention between auditory and visual domains. This study has implications for understanding: 1 the impact of splitting attention among different sensory modalities, and 2 the impact of embodiment, on perception of musical meter. Viewing dance may interfere with sound processing, particularly at critical metrical positions, but embodied

  14. Singularities of construction of static war-hour meters alternating-current

    Directory of Open Access Journals (Sweden)

    М.О. Петрище

    2004-04-01

    Full Text Available  The analysis of construction of static war-hour meters is carried out which are founded on use of specialized tools, which are intended for measurement of a active energy. The shortages of such methods concerning a possibility of unauthorized takeoff of an electric energy are marked through improper phasing of a current. The method is offered which allows to construct static war-hour meters insensitive to improper phasing of a current.

  15. Energy Autonomous Wireless Water Meter with Integrated Turbine Driven Energy Harvester

    Science.gov (United States)

    Becker, P.; Folkmer, B.; Goepfert, R.; Hoffmann, D.; Willmann, A.; Manoli, Y.

    2013-12-01

    Accurate meter reading is the fundamental task of the home water system for the handling of payments. Meters need to be read correctly, to avoid an effect of adding events that increase unnecessary cost and create customer dissatisfaction. This paper presents a fully integrated wireless, energy autonomous water metering system based on the European Standard EN 13757 "Communication systems for meters and remote reading of meters". The system can be used in multiple water metering scenarios. No maintenance will be required and the system will provide precise and secure data transmission as well as timely and accurate recording of the consumption of water. The identification of any leakages will be improved through the analysis of the actual quantity supplied and recorded by the meters. The system is powered by an energy harvester, based on a water driven turbine wheel that is directly coupled to an electromagnetic energy transducer. The power delivered by the generator is dependent of the amount of flowing water and the pressure in the water pipes. Therefor the power is commonly non-continuous, fluctuant and unstable in the voltage amplitude. To be able to report the meter readings at all times, the system needs to be powered not only in times when the energy harvester delivers energy. Therefor an energy buffer, that stores the harvested energy, is installed to compensate the energy requirement between the actual generator output and the energy consumption of the application. Besides a complete system overview, the presentation will focus on the power management and energy aware battery charging circuitry. The design, fabrication, measuring results and the preparations for field tests in rural and urban environment will be presented and discussed.

  16. Compact mass flow meter based on a micro Coriolis flow sensor

    NARCIS (Netherlands)

    Sparreboom, Wouter; Katerberg, M.R.; Lammerink, Theodorus S.J.; Postma, F.M.; Haneveld, J.; Groenesteijn, Jarno; Wiegerink, Remco J.; Lötters, Joost Conrad

    2012-01-01

    In this paper we present a compact ready-to-use micro Coriolis mass flow meter. The full scale flow is 2 g/h (for water at a pressure drop of 2 bar). It has a zero stability of 2 mg/h and an accuracy of 0.5% reading. The temperature drift between 10 and 50 ºC is below 1 mg/h/ºC. The meter is robust,

  17. Privacy-Preserving Smart Metering with Authentication in a Smart Grid

    OpenAIRE

    Jun Beom Hur; Dong Young Koo; Young Joo Shin

    2015-01-01

    The traditional security objectives of smart grids have been availability, integrity, and confidentiality. However, as the grids incorporate smart metering and load management, user and corporate privacy is increasingly becoming an issue in smart grid networks. Although transmitting current power consumption levels to the supplier or utility from each smart meter at short intervals has an advantage for the electricity supplier’s planning and management purposes, it threatens user privacy by d...

  18. Energy metering, management and accounting; Comptage, gestion, et comptabilite de l`energie

    Energy Technology Data Exchange (ETDEWEB)

    Foucherand, P. [Agence de l`environnement et de la maitrise de l`energie, Rhone-Alpes (France)

    1996-12-31

    The activities of the French Energy Conservation Agency (ADEME) in the field of energy management and conservation through energy metering in industrial plants, and more especially in mechanical and metal industries, are presented. Audit and diagnostic procedures and information/awareness measures are presented and discussed with the example of a regional program, and two operations conducted in a mechanical industrial plant and a foundry where metering systems were installed

  19. Influence of the operating pressure in flow metering systems using turbine meters-key factors; Influencia da pressao em sistemas de medicao de gas natural com totalizadores de volume do tipo turbina: fatores a considerar

    Energy Technology Data Exchange (ETDEWEB)

    Wilcek, Alanna; Picanco, Marco Antonio S. [Companhia de Gas de Santa Catarina (SCGAS), Florianopolis, SC (Brazil)

    2008-07-01

    Flow measurement is a strategic process in the Natural Gas transport and distribution industry. The diary measurement of the 43 million cubic meters consumed in Brazil is made by flow meters certified by the Rede Brasileira de Calibracao (Brazilian Calibration Network) and INMETRO. Turbine flow meters are commonly applied in high flow measurement systems. Some manufactures and authors discuss the sensibility of turbine meters to the operational conditions. The objective of this paper is to establish a discussion about the flow pressure effects in the turbine meter and the influence in measure errors. (author)

  20. Passive house at 3.000 meter. The new Monte-Rosa cottage; Passivhaus auf 3000 Meter. Die neue Monte-Rose-Huette

    Energy Technology Data Exchange (ETDEWEB)

    Sinn, Ruediger

    2010-02-15

    The extreme climatic conditions of the Alps complicate the work of the architects and civil engineers. A new trend to the modern was rung in by the construction of the new Monte Rosa cottage in the Swiss Wallis. In a height of nearly 3.000 meters, the cottage does not need energy from the outside. It is operated energy autonomously to 90 %.

  1. Determination of free CO2 in emergent groundwaters using a commercial beverage carbonation meter

    Science.gov (United States)

    Vesper, Dorothy J.; Edenborn, Harry M.

    2012-05-01

    SummaryDissolved CO2 in groundwater is frequently supersaturated relative to its equilibrium with atmospheric partial pressure and will degas when it is conveyed to the surface. Estimates of dissolved CO2 concentrations can vary widely between different hydrochemical facies because they have different sources of error (e.g., rapid degassing, low alkalinity, non-carbonate alkalinity). We sampled 60 natural spring and mine waters using a beverage industry carbonation meter, which measures dissolved CO2 based on temperature and pressure changes as the sample volume is expanded. Using a modified field protocol, the meter was found to be highly accurate in the range 0.2-35 mM CO2. The meter provided rapid, accurate and precise measurements of dissolved CO2 in natural waters for a range of hydrochemical facies. Dissolved CO2 concentrations measured in the field with the carbonation meter were similar to CO2 determined using the pH-alkalinity approach, but provided immediate results and avoided errors from alkalinity and pH determination. The portability and ease of use of the carbonation meter in the field made it well-suited to sampling in difficult terrain. The carbonation meter has proven useful in the study of aquatic systems where CO2 degassing drives geochemical changes that result in surficial mineral precipitation and deposition, such as tufa, travertine and mine drainage deposits.

  2. State of the Art and Trends Review of Smart Metering in Electricity Grids

    Directory of Open Access Journals (Sweden)

    Noelia Uribe-Pérez

    2016-02-01

    Full Text Available Climate change, awareness of energy efficiency, new trends in electricity markets, the obsolescence of the actual electricity model, and the gradual conversion of consumers to prosumer profiles are the main agents of progressive change in electricity systems towards the Smart Grid paradigm. The introduction of multiple distributed generation and storage resources, with a strong involvement of renewable energies, exposes the necessity of advanced metering or Smart Metering systems, able to manage and control those distributed resources. Due to the heterogeneity of the Smart Metering systems and the specific features of each grid, it is easy to find in the related literature a wide range of solutions with different features. This work describes the key elements in a Smart Metering system and compiles the most employed technologies and standards as well as their main features. Since Smart Metering systems can perform jointly with other activities, these growing initiatives are also addressed. Finally, a revision of the main trends in Smart Metering uses and deployments worldwide is included.

  3. IEEE Committee on Man and Radiation--COMAR technical information statement radiofrequency safety and utility Smart Meters.

    Science.gov (United States)

    Bushberg, Jerrold T; Foster, Kenneth R; Hatfield, James B; Thansandote, Arthur; Tell, Richard A

    2015-03-01

    This Technical Information Statement describes Smart Meter technology as used with modern electric power metering systems and focuses on the radio frequency (RF) emissions associated with their operation relative to human RF exposure limits. Smart Meters typically employ low power (-1 W or less) transmitters that wirelessly send electric energy usage data to the utility company several times per day in the form of brief, pulsed emissions in the unlicensed frequency bands of 902-928 MHz and 2.4-2.48 GHz or on other nearby frequencies. Most Smart Meters operate as wireless mesh networks where each Smart Meter can communicate with other neighboring meters to relay data to a data collection point in the region. This communication process includes RF emissions from Smart Meters representing energy usage as well as the relaying of data from other meters and emissions associated with maintaining the meter's hierarchy within the wireless network. As a consequence, most Smart Meters emit RF pulses throughout the day, more at certain times and less at others. However, the duty cycle associated with all of these emissions is very small, typically less than 1%, and most of the time far less than 1%, meaning that most Smart Meters actually transmit RF fields for only a few minutes per day at most. The low peak power of Smart Meters and the very low duty cycles lead to the fact that accessible RF fields near Smart Meters are far below both U.S. and international RF safety limits whether judged on the basis of instantaneous peak power densities or time-averaged exposures. This conclusion holds for Smart Meters alone or installed in large banks of meters.

  4. A tool to increase information-processing capacity for consumer water meter data

    Directory of Open Access Journals (Sweden)

    Heinz E. Jacobs

    2012-02-01

    Full Text Available Background: Water service providers invoice most South African urban consumers for the water they use every month. A secure treasury system generates water invoices at municipalities’ financial departments. Information about the water usage of customers initially comes from reading the water meters, usually located in gardens near the front boundaries of properties. Until as recently as 1990, the main purpose of the water meter readings was to generate invoices for water usage. There are various treasury systems for this purpose.Objective: The objective of this research article was to describe the development of Swift, a locally developed software tool for analysing water meter data from an information management perspective, which engineers in the water field generally use, and to assess critically the influence of Swift on published research and industry. This article focuses on water usage and the challenge of data interchange and extraction as issues that various industries face.Method: This article presents the first detailed report on Swift. It uses a detailed knowledge review and presents and summarises the findings chronologically.Results: The water meter data flow path used to be quite simple. The risk of breaches in confidentiality was limited. Technological advances over the years have led to additional knowledge coming from the same water meter readings with subsequent research outputs. However, there are also complicated data flow paths and increased risks. Users have used Swift to analyse more than two million consumers’ water meter readings to date. Studies have culminated in 10 peer-reviewed journal articles using the data. Seven of them were in the last five years.Conclusion: Swift-based data was the basis of various research studies in the past decade. Practical guidelines in the civil engineering fraternity for estimating water use in South Africa have incorporated knowledge from these studies. Developments after 1995 have

  5. Peak expiratory flow at increased barometric pressure: comparison of peak flow meters and volumetric spirometer.

    Science.gov (United States)

    Thomas, P S; Ng, C; Bennett, M

    2000-01-01

    Increasing numbers of patients are receiving hyperbaric oxygen therapy as an intensive care treatment, some of whom have pre-existing airway obstruction. Spirometers are the ideal instruments for measuring airway obstruction, but peak flow meters are useful and versatile devices. The behaviour of both types of device was therefore studied in a hyperbaric unit under conditions of increased pressure. It is important to have a non-electrical indicator of airway obstruction, to minimize the fire risk in the hyperoxic environment. The hypothesis was tested that, assuming that dynamic resistance is unchanged, both the Wright's standard and mini-peak flow meters would over-read peak expiratory flow (PEF) under increased pressure when compared with a volumetric spirometer, as the latter is unaffected by air density. It was postulated that a correction factor could be derived so that PEF meters could be used in this setting. Seven normal subjects performed volume-dependent spirometry to derive PEF, and manoeuvres using both standard and mini PEF meters at sea level, under hyperbaric conditions at 303, 253 and 152 kPa (3, 2.5 and 1.5 atmospheres respectively; 1 atmosphere absolute=101.08 kPa), and again at sea level. There was a progressive and significant decline in PEF with increasing pressure as measured by the spirometer (69.46+/-0.8% baseline at 303 kPa compared with 101 kPa), while the PEF meters showed a progressive increase in their readings (an increase of 7.86+/-1.69% at 303 kPa with the mini PEF meter). Using these data points, a correction factor was derived which allows appropriate values to be calculated from the Wright's meter readings under these conditions.

  6. Using Wireless Power Meters to Measure Energy Use of Miscellaneous and Electronic Devices in Buildings

    Energy Technology Data Exchange (ETDEWEB)

    UC Berkeley, Berkeley, CA USA; Brown, Richard; Lanzisera, Steven; Cheung, Hoi Ying (Iris); Lai, Judy; Jiang, Xiaofan; Dawson-Haggerty, Stephen; Taneja, Jay; Ortiz, Jorge; Culler, David

    2011-05-24

    Miscellaneous and electronic devices consume about one-third of the primary energy used in U.S. buildings, and their energy use is increasing faster than other end-uses. Despite the success of policies, such as Energy Star, that promote more efficient miscellaneous and electronic products, much remains to be done to address the energy use of these devices if we are to achieve our energy and carbon reduction goals. Developing efficiency strategies for these products depends on better data about their actual usage, but very few studies have collected field data on the long-term energy used by a large sample of devices due to the difficulty and expense of collecting device-level energy data. This paper describes the development of an improved method for collecting device-level energy and power data using small, relatively inexpensive wireless power meters. These meters form a mesh network based on Internet standard protocols and can form networks of hundreds of metering points in a single building. Because the meters are relatively inexpensive and do not require manual data downloading, they can be left in the field for months or years to collect long time-series energy use data. In addition to the metering technology, we also describe a field protocol used to collect comprehensive, robust data on the miscellaneous and electronic devices in a building. The paper presents sample results from several case study buildings, in which all the plug-in devices for several homes were metered, and a representative sample of several hundred plug-in devices in a commercial office building were metered for several months.

  7. Design and Development of Thermistor based Power Meter at 140 GHz Frequency Band

    Science.gov (United States)

    Roy, Rajesh; Kush, Abhimanyue Kumar; Dixit, Rajendra Prasad

    2011-12-01

    Design and development of thermistor based power meter at 140 gigahertz (GHz) frequency band have been presented. Power meter comprises power sensor, amplifier circuit and dialog based graphical user interface in visual C++ for the average power measurement. The output power level of a component or system is very critical design factor. Thus there was a need of a power meter for the development of millimeter wave components at 140 GHz frequency band. Power sensor has been designed and developed using NTC (Negative Temperature Coefficient) thermistors. The design aims at developing a direct, simple and inexpensive power meter that can be used to measure absolute power at 140 GHz frequency band. Due to absorption of 140 GHz frequencies, resistance of thermistor changes to a new value. This change in resistance of thermistor can be converted to a dc voltage change and amplified voltage change can be fed to computer through data acquisition card. Dialog based graphical user interface (GUI) has been developed in visual C++ language for average power measurement in dBm. WR6 standard rectangular waveguide is the input port for the sensor of power meter. Temperature compensation has been achieved. Moderate sensor return loss greater than 20 dB has been found over the frequency range 110 to 170 GHz. The response time of the power sensor is 10 second. Average power accuracy is better than ±0.25 dB within the power range from -10 to 10 dBm at 140 GHz frequency band.

  8. TRL Assessment of Solar Sail Technology Development Following the 20-Meter System Ground Demonstrator Hardware Testing

    Science.gov (United States)

    Young, Roy M.; Adams, Charles L.

    2010-01-01

    The NASA In-Space Propulsion Technology (ISPT) Projects Office sponsored two separate, independent solar sail system design and development demonstration activities during 2002-2005. ATK Space Systems of Goleta, CA was the prime contractor for one development team and L' Garde, Inc. of Tustin, CA was the prime contractor for the other development team. The goal of these activities was to advance the technology readiness level (TRL) of solar sail propulsion from 3 towards 6 by the year 2006. Component and subsystem fabrication and testing were completed successfully, including the ground deployment of 10-meter and 20-meter demonstration hardware systems under vacuum conditions. The deployment and structural testing of the 20-meter solar sail systems was conducted in the 30 meter diameter Space Power Facility thermal-vacuum chamber at NASA Glenn Plum Brook in April though August, 2005. This paper will present the results of the TRL assessment following the solar sail technology development activities associated with the design, development, analysis and testing of the 20-meter system ground demonstrators.

  9. Development and evaluation of an automated system for testing current meters

    Directory of Open Access Journals (Sweden)

    Ezequiel Saretta

    2016-02-01

    Full Text Available ABSTRACT Current meters are equipment widely used for estimating flow velocity in rivers and streams. Periodic calibrations of current meters are important to ensure the quality of measurements, but the required testing facilities are complex and only available in a few institutions. However, advances in electronics and automation may contribute to developing simple and reliable calibration systems. Thus, this study aimed to develop an automated system for testing current meters, which consisted of a trapezoidal channel, a step motor, a tow car and a management system, composed of a supervisory application and microprocessed modules to control the motor and the data acquisition. Evaluations of the displacement velocity showed that it matched the reference value up to 1.85 m s-1 for a vertical-axis current meter and 2.3 m s-1 for a horizontal-axis one. The developed system showed reliability during tests, for both current meter movement and data acquisition. The management of the system based on the developed modules and the supervisory application improved its user interface, turning all the procedure into a simple task.

  10. A tool to increase information-processing capacity for consumer water meter data

    Directory of Open Access Journals (Sweden)

    Heinz E. Jacobs

    2012-06-01

    Objective: The objective of this research article was to describe the development of Swift, a locally developed software tool for analysing water meter data from an information management perspective, which engineers in the water field generally use, and to assess critically the influence of Swift on published research and industry. This article focuses on water usage and the challenge of data interchange and extraction as issues that various industries face. Method: This article presents the first detailed report on Swift. It uses a detailed knowledge review and presents and summarises the findings chronologically. Results: The water meter data flow path used to be quite simple. The risk of breaches in confidentiality was limited. Technological advances over the years have led to additional knowledge coming from the same water meter readings with subsequent research outputs. However, there are also complicated data flow paths and increased risks. Users have used Swift to analyse more than two million consumers’ water meter readings to date. Studies have culminated in 10 peer-reviewed journal articles using the data. Seven of them were in the last five years. Conclusion: Swift-based data was the basis of various research studies in the past decade. Practical guidelines in the civil engineering fraternity for estimating water use in South Africa have incorporated knowledge from these studies. Developments after 1995 have increased the information processing capacity for water meter data.

  11. Electricity theft: Overview, issues, prevention and a smart meter based approach to control theft

    Energy Technology Data Exchange (ETDEWEB)

    Depuru, Soma Shekara Sreenadh Reddy, E-mail: sdepuru@rockets.utoledo.ed [Department of Electrical Engineering and Computer Science, University of Toledo, Toledo, OH 43606 (United States); Wang Lingfeng, E-mail: Lingfeng.Wang@utoledo.ed [Department of Electrical Engineering and Computer Science, University of Toledo, Toledo, OH 43606 (United States); Devabhaktuni, Vijay, E-mail: Vijay.Devabhaktuni@utoledo.ed [Department of Electrical Engineering and Computer Science, University of Toledo, Toledo, OH 43606 (United States)

    2011-02-15

    Non-technical loss (NTL) during transmission of electrical energy is a major problem in developing countries and it has been very difficult for the utility companies to detect and fight the people responsible for theft. Electricity theft forms a major chunk of NTL. These losses affect quality of supply, increase load on the generating station, and affect tariff imposed on genuine customers. This paper discusses the factors that influence the consumers to steal electricity. In view of these ill effects, various methods for detection and estimation of the theft are discussed. This paper proposes an architectural design of smart meter, external control station, harmonic generator, and filter circuit. Motivation of this work is to deject illegal consumers, and conserve and effectively utilize energy. As well, smart meters are designed to provide data of various parameters related to instantaneous power consumption. NTL in the distribution feeder is computed by external control station from the sending end information of the distribution feeder. If a considerable amount of NTL is detected, harmonic generator is operated at that feeder for introducing additional harmonic component for destroying appliances of the illegal consumers. For illustration, cost-benefit analysis for implementation of the proposed system in India is presented. - Research Highlights: {yields} Discusses several cases, issues and setbacks in the design of smart meters. {yields} Evaluates socio-economic, infrastructural, political and power quality issues. {yields} Proposes a smart meter that overcame several setbacks in implementation. {yields} Proposes a smart meter that chastises appliances of illegal consumers.

  12. Telecommunication Technologies for Smart Grid Projects with Focus on Smart Metering Applications

    Directory of Open Access Journals (Sweden)

    Nikoleta Andreadou

    2016-05-01

    Full Text Available This paper provides a study of the smart grid projects realised in Europe and presents their technological solutions with a focus on smart metering Low Voltage (LV applications. Special attention is given to the telecommunications technologies used. For this purpose, we present the telecommunication technologies chosen by several European utilities for the accomplishment of their smart meter national roll-outs. Further on, a study is performed based on the European Smart Grid Projects, highlighting their technological options. The range of the projects analysed covers the ones including smart metering implementation as well as those in which smart metering applications play a significant role in the overall project success. The survey reveals that various topics are directly or indirectly linked to smart metering applications, like smart home/building, energy management, grid monitoring and integration of Renewable Energy Sources (RES. Therefore, the technological options that lie behind such projects are pointed out. For reasons of completeness, we also present the main characteristics of the telecommunication technologies that are found to be used in practice for the LV grid.

  13. Simplified and quantitative saliva buffer capacity test using a hand-held pH meter.

    Science.gov (United States)

    Kitasako, Yuichi; Moritsuka, Michiyo; Foxton, Richard M; Ikeda, Masaomi; Tagami, Junji; Nomura, Satoshi

    2005-06-01

    To evaluate and compare saliva buffer capacity using a hand-held pH meter and a commercial buffer strip in patients at risk of caries. To obtain stimulated saliva, 109 patients were given a paraffin wax to chew for 5 minutes. After reading the pH value of 0.5 ml of tested saliva using a portable hand-held pH meter (B-212), 10 microl of 0.1N HCl was titrated into the obtained saliva up to a total titration of 160 microl, and then the pH value read each time. The commercial buffer strip (CRT) was also evaluated. The correlation in ranking results (high, medium, low) between the B-212 pH meter and CRT buffer were statistically analyzed by the Bartlett's test (P buffer capacity were 50%, 17% and 33% respectively for the B-212 pH meter, and 56%, 17% and 27% respectively for the CRT. For the CRT buffer, 23 out of 109 cases showed inconclusive color change under the colorimetric test. There was significant correlation between ranking buffer capacity measured by the B-212 pH meter and the CRT buffer (P < 0.001).

  14. Performance of radiation survey meters in X- and gamma-radiation fields.

    Science.gov (United States)

    Ceklic, Sandra; Arandjic, Danijela; Zivanovic, Milos; Ciraj-Bjelac, Olivera; Lazarevic, Djordje

    2014-11-01

    The aim of this work was to investigate the different types of radiation detectors commonly used for radiation protection purposes as survey meters. The study was performed on survey meters that use different detectors as ionisation chamber, Geiger Mueller (GM) counter and scintillation detector. For each survey meter, energy dependence and angular response in X- and gamma-radiation fields was tested. The following commercially available survey meters were investigated: ionisation chambers Victoreen 451P, Babyline 31 and VA-J-15A, Geiger counter MRK-M87, 6150 AD6 and FAG FH 40F2 and scintillation counter 6150 ADB. As a source of gamma radiation, (137)Cs and (60)Co were used whereas X-ray radiation fields were generated using an X-ray unit. The radiation characteristics of the survey meters were mostly in compliance with references estimated by standard IEC 1017-2. However, some of them showed larger deviation at lower energies. GM counters exhibit strong energy dependence for low-energy photons. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Smart meter deployment optimisation and its analysis for appliance load monitoring

    Directory of Open Access Journals (Sweden)

    Ahmed Shaharyar Khwaja

    2015-04-01

    Full Text Available In this study, the authors study the problem of smart meter deployment optimisation for appliance load monitoring, that is, to monitor a number of devices without any ambiguity using the minimum number of low-cost smart meters. The importance of this problem is due to the fact that the number of meters should be reduced to decrease the deployment cost, improve reliability and decrease congestion. In this way, in future, smart meters can provide additional information about the type and number of distinct devices connected, besides their normal functionalities concerned with providing overall energy measurements and their communication. The authors present two exact smart meter deployment optimisation algorithms, one based on exhaustive search and the other based on efficient implementation of the exhaustive search. They formulate the problem mathematically and present computational complexity analysis of their algorithms. Simulation scenarios show that for a typical number of home appliances, the efficient search method is significantly faster compared to the exhaustive search and can provide the same optimal solution. The authors also show the dependency of their method on the distribution of the load pattern that can potentially be in a typical household.

  16. ANALYZING SHORT (100 METERS AND MIDDLE DISTANCE (800 - 1200 METERS RUNNING AND COORDINATION VALUES ACCORDING TO SPORTS BRANCHES OF STUDENTS WHO TAKE ENTRANCE EXAMS TO SPORTS HIGH SCHOOL

    Directory of Open Access Journals (Sweden)

    Ahmet Yılmaz ALBAYRAK

    2014-06-01

    Full Text Available In this study, t h e p u r p o s e was to determine the changes in accordance with running and coordination values of children who took the entrance examinations of sports high scholl in the 5 year period and assess them according to the branches as 100 and 800 meters running for female, 100 and 1200 meters running for men. In accordance with this aim, test values of total 1306 students (m = 1061, f = 245, average age = 14 who participated in entrance examinations in a 5 years duration including 2008, 2 009, 2010, 2011, 2012 years in the region of Antalya for sports high school were analyzed. As an statistical analyze, One way ANOVA and multiple comparison tests (which are LSD, Least Significant Difference tests were used. As a result of statistical anal yses, although the candidates who took the tests in the region of Antalya, change along 5 years duration, while obtaining a statistically significant difference in the running values of male children (p0,05. Likewise, while obtaining a statistically significant difference in 100 meters running values of female children (p0,05. In addition there was no any statistically significant difference in 100, 800 meters running values and coordination values of female children according to branches (p>0,05. Consequently, it can be suggested that there were no changes in speed times of both male and female children in along 5 years duration in region of Antalya. It can be inferred that while there is a significant change in values of running and coordination of males, the reason why female children were not able to show c hanges in their values should be because they show less imrovement in sports branches. In addition, male students in track and field branch gained the highest degrees both in 100 m and coordination tracks. Thus, it can be said that someone having good spee d has good coordination too.

  17. The Study on the Design of the Function and Date Structure for Electronic Watt-Hour Meters

    Energy Technology Data Exchange (ETDEWEB)

    Jang, M.J.; Hyun, D.H.; Cho, S.K. [Korea Electric Power Reserch Institute (Korea)

    2001-07-01

    With the development of Computer and Communication Technology, nowadays many people are interested in remote metering, and many vendors are suggesting various remote metering solutions, KEPCO (Korea Electric Power Corporation) adopts some of these to some customers who uses a lot of electric power, also continues researching them. But, currently used electronic watt-hour meters vary in terms of communication protocol and data structure to construct a remote metering system, or to find problems in it. But that's impossible to know each vendor's protocol and data structure because they are reluctant to tell those to outside the company. To solve these problems and to make a much more cost-effective metering system, KEPCO developed standard communication protocol between meters and PC (or metering server), and defined standard functions and data structure which can be used by everyone easily. Those developments support standard interface for every vendor's meters. And those will be adopted by KEPCO for a part of a new metering standard for electric watt-hour meters. (author). 8 refs., 7 figs., 1 tab.

  18. A transit-time flow meter for measuring milliliter per minute liquid flow

    DEFF Research Database (Denmark)

    Yang, Canqian; Kymmel, Mogens; Søeberg, Henrik

    1988-01-01

    A transit-time flow meter, using periodic temperature fluctuations as tracers, has been developed for measuring liquid flow as small as 0.1 ml/min in microchannels. By injecting square waves of heat into the liquid flow upstream with a tiny resistance wire heater, periodic temperature fluctuations...... are generated downstream. The fundamental frequency phase shift of the temperature signal with respect to the square wave is found to be a linear function of the reciprocal mean velocity of the fluid. The transit-time principle enables the flow meter to have high accuracy, better than 0.2%, and good linearity....... This flow meter will be used to measure and control the small liquid flow in microchannels in flow injection analysis. Review of Scientific Instruments is copyrighted by The American Institute of Physics....

  19. Design and calibration of a novel transient radiative heat flux meter for a spacecraft thermal test.

    Science.gov (United States)

    Sheng, Chunchen; Hu, Peng; Cheng, Xiaofang

    2016-06-01

    Radiative heat flux measurement is significantly important for a spacecraft thermal test. To satisfy the requirements of both high accuracy and fast response, a novel transient radiative heat flux meter was developed. Its thermal receiver consists of a central thermal receiver and two thermal guarded annular plates, which ensure the temperature distribution of the central thermal receiver to be uniform enough for reasonably applying lumped heat capacity method in a transient radiative heat flux measurement. This novel transient radiative heat flux meter design can also take accurate measurements regardless of spacecraft surface temperature and incident radiation spectrum. The measurement principle was elaborated and the coefficients were calibrated. Experimental results from testing a blackbody furnace and an Xenon lamp show that this novel transient radiative heat flux meter can be used to measure transient radiative heat flux up to 1400 W/m(2) with high accuracy and the response time of less than 10 s.

  20. Effects of temperature-gradient-induced damage of zirconia metering nozzles

    Science.gov (United States)

    Zhao, Liang; Xue, Qun-hu

    2017-09-01

    The effects of temperature-gradient-induced damage of zirconia metering nozzles were investigated through analysis of the phase composition and microstructure of nozzle samples. The analysis was carried out using X-ray diffraction and scanning electron microscopy after the samples were subjected to a heat treatment based on the temperatures of the affected, transition, and original layers of zirconia metering nozzles during the continuous casting of steel. The results showed that, after heat treatment at 1540, 1410, or 1300°C for a dwell time of 5 h, the monoclinic zirconia phase was gradually stabilized with increasing heat-treatment temperature. Moreover, a transformation to the cubic zirconia phase occurred, accompanied by grain growth, which illustrates that the temperature gradient in zirconia metering nozzles affects the mineral composition and microstructure of the nozzles and accelerates damage, thereby deteriorating the quality and service life of the nozzles.

  1. Design of DRMS(Distribution Remote Management System) Based on Advanced Digital Kwh-Meter

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Yon Seok; Lim, Chul Su; Lee, Kyung Ho [Namseoul University (Korea); Kim, Yun Jib; Yun, Sang Moon; Seo, Seong Jin [Kwangwoon University (Korea)

    2002-07-01

    This paper proposes a DRMS(Distribution Remote Management System) based on the advanced digital kwh-meter. The proposed DRMS is designed so as to be able to collect the voltage management data, the load management data as well as the used kwh data from advanced kwh-meter remotelly. It makes the integrated management of distribution system possible and enhances highly the economics of the existing remote meter-reading system based in the only used kwh-data. Also it can improve highly the quality of power supplied to the electric customer by minimizing the voltage management cost and by enhancing the efficiency of load management. (author). 2 refs., 4 figs., 5 tabs.

  2. Real Time Phase Noise Meter Based on a Digital Signal Processor

    Science.gov (United States)

    Angrisani, Leopoldo; D'Arco, Mauro; Greenhall, Charles A.; Schiano Lo Morille, Rosario

    2006-01-01

    A digital signal-processing meter for phase noise measurement on sinusoidal signals is dealt with. It enlists a special hardware architecture, made up of a core digital signal processor connected to a data acquisition board, and takes advantage of a quadrature demodulation-based measurement scheme, already proposed by the authors. Thanks to an efficient measurement process and an optimized implementation of its fundamental stages, the proposed meter succeeds in exploiting all hardware resources in such an effective way as to gain high performance and real-time operation. For input frequencies up to some hundreds of kilohertz, the meter is capable both of updating phase noise power spectrum while seamlessly capturing the analyzed signal into its memory, and granting as good frequency resolution as few units of hertz.

  3. 20-meter underwater wireless optical communication link with 1.5 Gbps data rate.

    Science.gov (United States)

    Shen, Chao; Guo, Yujian; Oubei, Hassan M; Ng, Tien Khee; Liu, Guangyu; Park, Ki-Hong; Ho, Kang-Ting; Alouini, Mohamed-Slim; Ooi, Boon S

    2016-10-31

    The video streaming, data transmission, and remote control in underwater call for high speed (Gbps) communication link with a long channel length (~10 meters). We present a compact and low power consumption underwater wireless optical communication (UWOC) system utilizing a 450-nm laser diode (LD) and a Si avalanche photodetector. With the LD operating at a driving current of 80 mA with an optical power of 51.3 mW, we demonstrated a high-speed UWOC link offering a data rate up to 2 Gbps over a 12-meter-long, and 1.5 Gbps over a record 20-meter-long underwater channel. The measured bit-error rate (BER) are 2.8 × 10-5, and 3.0 × 10-3, respectively, which pass well the forward error correction (FEC) criterion.

  4. A simple protocol for the routine calibration of pH meters

    Directory of Open Access Journals (Sweden)

    A. FEDERMAN NETO

    2009-01-01

    Full Text Available

    A simplified laboratory protocol for the calibration of pH meters is described and tested. It is based on the use of two analytical primary buffer solutions, potassium hydrogen phthalate and Borax (sodium tetraborate decahydrate of precisely known concentrations and pH. The solutions may be stored at room temperature for long periods, without decomposition and used directly. The calibration of the meter can be checked with standard solutions of sodium dihydrogen phosphate, sodium carbonate, sodium benzoate, sodium salicylate or potassium oxalate. Methods for the purification of Borax and potassium chloride are also given, and a new method for the neutralization of 0.9% saline is suggested. Keywords: pH meters (calibration; saline (0.9%; pH standards; potassium biphthalate; Borax.

  5. 20-meter underwater wireless optical communication link with 15 Gbps data rate

    KAUST Repository

    Shen, Chao

    2016-10-24

    The video streaming, data transmission, and remote control in underwater call for high speed (Gbps) communication link with a long channel length (∼10 meters). We present a compact and low power consumption underwater wireless optical communication (UWOC) system utilizing a 450-nm laser diode (LD) and a Si avalanche photodetector. With the LD operating at a driving current of 80 mA with an optical power of 51.3 mW, we demonstrated a high-speed UWOC link offering a data rate up to 2 Gbps over a 12-meter-long, and 1.5 Gbps over a record 20-meter-long underwater channel. The measured bit-error rate (BER) are 2.8 × 10-5, and 3.0 × 10-3, respectively, which pass well the forward error correction (FEC) criterion. © 2016 Optical Society of America.

  6. Improving SCATS Operation during Congestion Periods Using Internal/External Traffic Metering Strategy

    Directory of Open Access Journals (Sweden)

    Shahriar Afandizadeh Zargari

    2016-02-01

    Full Text Available Traffic metering is one of the effective strategies of preventing gridlock at urban signalized intersections during oversaturated conditions. This strategy could be implemented by adjusting signal timing schemes of the connected intersections of congested network in dynamic setting. This paper demonstrates the benefits of internal/external traffic metering strategy on a real case study in Tehran, the capital of Iran. For this purpose, the model outputs have been considered as input to set of SCATS scenarios for signal timing. In each test case the system is forced to use plans obtained from the model instead of using common built-in plans that had been used before, and the performance is measured using the VISSIM simulator to show differences. The results show significant improvement in network average travel time when using internal/external traffic metering strategy. Additionally, the average queue lengths are maintained near the optimal level since the model utilizes upstream arterial capacity.

  7. How Many Smart Meters can be Deployed in a GSM cell?

    DEFF Research Database (Denmark)

    Madueño, Germán Corrales; Stefanovic, Cedomir; Popovski, Petar

    2013-01-01

    The need to deploy large number of wireless devices, such as electricity or water meters, is becoming a key challenge for any utility. Furthermore, such a deployment should be functional for more than a decade. Many cellular operators consider LTE to be the single long term solution for wide area...... the network stability. We show that a single GSM cell can support simultaneous low-data rate connections (e. g. to smart meters) in the order of 104 devices.......The need to deploy large number of wireless devices, such as electricity or water meters, is becoming a key challenge for any utility. Furthermore, such a deployment should be functional for more than a decade. Many cellular operators consider LTE to be the single long term solution for wide area...

  8. Data Mining Techniques for Detecting Household Characteristics Based on Smart Meter Data

    Directory of Open Access Journals (Sweden)

    Krzysztof Gajowniczek

    2015-07-01

    Full Text Available The main goal of this research is to discover the structure of home appliances usage patterns, hence providing more intelligence in smart metering systems by taking into account the usage of selected home appliances and the time of their usage. In particular, we present and apply a set of unsupervised machine learning techniques to reveal specific usage patterns observed at an individual household. The work delivers the solutions applicable in smart metering systems that might: (1 contribute to higher energy awareness; (2 support accurate usage forecasting; and (3 provide the input for demand response systems in homes with timely energy saving recommendations for users. The results provided in this paper show that determining household characteristics from smart meter data is feasible and allows for quickly grasping general trends in data.

  9. Is Advanced Real-Time Energy Metering Sufficient to Persuade People to Save Energy?

    Directory of Open Access Journals (Sweden)

    Leite H.

    2012-10-01

    Full Text Available In order to promote a low-carbon economy, EU citizens may soon be able to check their electricity consumption from smart meter. It is hoped that smart meter can, by providing real-time consumption and pricing information to residential users, help reducing demand for electricity. It is argued in this paper that, according the Elaborative Likelihood Model (ELM, these methods are most likely to be effective when consumers perceive the issue of energy conservation relevant to their lives. Nevertheless, some fundamental characteristics of these methods result in limited amount of perceived personal relevance; for instance, energy expenditure expense may be relatively small comparing to other household expenditure like mortgage and consumption information does not enhance interpersonal trust. In this paper, it is suggested that smart meter can apply the “nudge” approaches which respond to ELM as the use of simple rules to make decision, which include the change of feedback delivery and device design.

  10. RAE: The Rainforest Automation Energy Dataset for Smart Grid Meter Data Analysis

    Directory of Open Access Journals (Sweden)

    Stephen Makonin

    2018-02-01

    Full Text Available Datasets are important for researchers to build models and test how well their machine learning algorithms perform. This paper presents the Rainforest Automation Energy (RAE dataset to help smart grid researchers test their algorithms that make use of smart meter data. This initial release of RAE contains 1 Hz data (mains and sub-meters from two residential houses. In addition to power data, environmental and sensor data from the house’s thermostat is included. Sub-meter data from one of the houses includes heat pump and rental suite captures, which is of interest to power utilities. We also show an energy breakdown of each house and show (by example how RAE can be used to test non-intrusive load monitoring (NILM algorithms.

  11. Measurements and modeling of the wind profile up to 600 meters at a flat coastal site

    DEFF Research Database (Denmark)

    Batchvarova, Ekaterina; Gryning, Sven-Erik; Floors, Rogier Ralph

    2014-01-01

    This study shows long-term ABL wind profile features by comparing long-range wind lidar measurements and the output from a mesoscale model. The study is based on one-year pulsed lidar (Wind Cube 70) measurements of wind speed and direction from 100 to 600 meters with vertical resolution of 50...... as function of height. It is found that 1) WRF is generally under predicting both the profiles of the measured wind speed, direction and power density, 2) the scatter of observations to model results of the wind speed does not change significantly with height between 100 and 600 meters, and 3) the scale (A...... meters and time resolution of 10 minutes at a coastal site on the West coast of Denmark and WRF ARW (NCAR) simulations for the same period. The model evaluation is performed based on wind speed, wind direction, as well as statistical parameters of the Weibull distribution of the wind speed time series...

  12. Real time monitoring of radial distribution system through optimal PSO meter location

    Energy Technology Data Exchange (ETDEWEB)

    Ramesh, L. [Jadavpur Univ., Kolkotta (India); Chowdhury, S.P.; Chowdhury, S.; Gaunt, C.T. [Cape Town Univ., (South Africa)

    2009-07-01

    Measurement data collected for remote thermal units (RTUs) are often contaminated by measuring device errors and telemeter noise. This paper presented a new algorithm for the optimal placement of meters used for power system state estimation (SE). The algorithm was designed to reduce the total investment cost for the meters as well as to increase state estimation accuracy. A particle swarm optimization (PSO) algorithm was used to enhance state estimation accuracy. The algorithm was tested using data from the Tamil Nadu Electricity Board in India. The product of the binary decision variable vector and the cost vector were combined to determine the total installation cost of the meters. The control system was monitored by a SCADA device and an RTU. The binary PSO algorithm was used to update velocity vector and determine the global best solution. It was concluded that measured values obtained from the algorithm can be used to estimate the state of the system. 20 refs., 8 figs.

  13. Measuring Neural Entrainment to Beat and Meter in Infants: Effects of Music Background.

    Science.gov (United States)

    Cirelli, Laura K; Spinelli, Christina; Nozaradan, Sylvie; Trainor, Laurel J

    2016-01-01

    Caregivers often engage in musical interactions with their infants. For example, parents across cultures sing lullabies and playsongs to their infants from birth. Behavioral studies indicate that infants not only extract beat information, but also group these beats into metrical hierarchies by as early as 6 months of age. However, it is not known how this is accomplished in the infant brain. An EEG frequency-tagging approach has been used successfully with adults to measure neural entrainment to auditory rhythms. The current study is the first to use this technique with infants in order to investigate how infants' brains encode rhythms. Furthermore, we examine how infant and parent music background is associated with individual differences in rhythm encoding. In Experiment 1, EEG was recorded while 7-month-old infants listened to an ambiguous rhythmic pattern that could be perceived to be in two different meters. In Experiment 2, EEG was recorded while 15-month-old infants listened to a rhythmic pattern with an unambiguous meter. In both age groups, information about music background (parent music training, infant music classes, hours of music listening) was collected. Both age groups showed clear EEG responses frequency-locked to the rhythms, at frequencies corresponding to both beat and meter. For the younger infants (Experiment 1), the amplitudes at duple meter frequencies were selectively enhanced for infants enrolled in music classes compared to those who had not engaged in such classes. For the older infants (Experiment 2), amplitudes at beat and meter frequencies were larger for infants with musically-trained compared to musically-untrained parents. These results suggest that the frequency-tagging method is sensitive to individual differences in beat and meter processing in infancy and could be used to track developmental changes.

  14. Design of an Open Smart Energy Gateway for Smart Meter Data Management

    Energy Technology Data Exchange (ETDEWEB)

    Page, Janie [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); McParland, Chuck [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Piette, Mary Ann [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Czarnecki, Stephen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-03-01

    With the widespread deployment of electronic interval meters, commonly known as smart meters, came the promise of real-time data on electric energy consumption. Recognizing an opportunity to provide consumers access to their near real-time energy consumption data directly from their installed smart meter, we designed a mechanism for capturing those data for consumer use via an open smart energy gateway (OpenSEG). By design, OpenSEG provides a clearly defined boundary for equipment and data ownership. OpenSEG is an open-source data management platform to enable better data management of smart meter data. Effectively, it is an information architecture designed to work with the ZigBee Smart Energy Profile 1.x (SEP 1.x). It was specifically designed to reduce cyber-security risks and provide secure information directly from smart meters to consumers in near real time, using display devices already owned by the consumers. OpenSEG stores 48 hours of recent consumption data in a circular cache using a format consistent with commonly available archived (not real-time) consumption data such as Green Button, which is based on the Energy Services Provider Interface (ESPI) data standard. It consists of a common XML format for energy usage information and a data exchange protocol to facilitate automated data transfer upon utility customer authorization. Included in the design is an application program interface by which users can acquire data from OpenSEG for further post processing. A sample data display application is included in the initial software product. The data display application demonstrates that OpenSEG can help electricity use data to be retrieved from a smart meter and ported to a wide variety of user-owned devices such as cell phones or a user-selected database. This system can be used for homes, multi-family buildings, or small commercial buildings in California.

  15. OTRA-THS MAC to reduce Power Outage Data Collection Latency in a smart meter network

    Energy Technology Data Exchange (ETDEWEB)

    Garlapati, Shravan K [ORNL; Kuruganti, Phani Teja [ORNL; Buehrer, Richard M [ORNL; Reed, Jeffrey H [ORNL

    2014-01-01

    The deployment of advanced metering infrastructure by the electric utilities poses unique communication challenges, particularly as the number of meters per aggregator increases. During a power outage, a smart meter tries to report it instantaneously to the electric utility. In a densely populated residential/industrial locality, it is possible that a large number of smart meters simultaneously try to get access to the communication network to report the power outage. If the number of smart meters is very high of the order of tens of thousands (metropolitan areas), the power outage data flooding can lead to Random Access CHannel (RACH) congestion. Several utilities are considering the use of cellular network for smart meter communications. In 3G/4G cellular networks, RACH congestion not only leads to collisions, retransmissions and increased RACH delays, but also has the potential to disrupt the dedicated traffic flow by increasing the interference levels (3G CDMA). In order to overcome this problem, in this paper we propose a Time Hierarchical Scheme (THS) that reduces the intensity of power outage data flooding and power outage reporting delay by 6/7th, and 17/18th when compared to their respective values without THS. Also, we propose an Optimum Transmission Rate Adaptive (OTRA) MAC to optimize the latency in power outage data collection. The analysis and simulation results presented in this paper show that both the OTRA and THS features of the proposed MAC results in a Power Outage Data Collection Latency (PODCL) that is 1/10th of the 4G LTE PODCL.

  16. Measuring Neural Entrainment to Beat and Meter in Infants: Effects of Music Background

    Science.gov (United States)

    Cirelli, Laura K.; Spinelli, Christina; Nozaradan, Sylvie; Trainor, Laurel J.

    2016-01-01

    Caregivers often engage in musical interactions with their infants. For example, parents across cultures sing lullabies and playsongs to their infants from birth. Behavioral studies indicate that infants not only extract beat information, but also group these beats into metrical hierarchies by as early as 6 months of age. However, it is not known how this is accomplished in the infant brain. An EEG frequency-tagging approach has been used successfully with adults to measure neural entrainment to auditory rhythms. The current study is the first to use this technique with infants in order to investigate how infants' brains encode rhythms. Furthermore, we examine how infant and parent music background is associated with individual differences in rhythm encoding. In Experiment 1, EEG was recorded while 7-month-old infants listened to an ambiguous rhythmic pattern that could be perceived to be in two different meters. In Experiment 2, EEG was recorded while 15-month-old infants listened to a rhythmic pattern with an unambiguous meter. In both age groups, information about music background (parent music training, infant music classes, hours of music listening) was collected. Both age groups showed clear EEG responses frequency-locked to the rhythms, at frequencies corresponding to both beat and meter. For the younger infants (Experiment 1), the amplitudes at duple meter frequencies were selectively enhanced for infants enrolled in music classes compared to those who had not engaged in such classes. For the older infants (Experiment 2), amplitudes at beat and meter frequencies were larger for infants with musically-trained compared to musically-untrained parents. These results suggest that the frequency-tagging method is sensitive to individual differences in beat and meter processing in infancy and could be used to track developmental changes. PMID:27252619

  17. Energy Renovation of Buildings Utilizing the U-value Meter, a New Heat Loss Measuring Device

    OpenAIRE

    Lars Schiøtt Sørensen

    2010-01-01

    A new device with the ability to measure heat loss from building facades is proposed. Yet to be commercially developed, the U-value Meter can be used as stand-alone apparatus, or in combination with thermographic-equipment. The U-value meter complements thermographs, which only reproduce surface temperature and not the heat loss distribution. There is need for a device that measures the heat loss in a quantitative manner. Convective as well as radiative heat losses are captured and measured w...

  18. Evaluation of a metering, mixing, and dispensing system for mixing polysulfide adhesive

    Science.gov (United States)

    Evans, Kurt B.

    1989-01-01

    Tests were performed to evaluate whether a metered mixing system can mix PR-1221 polysulfide adhesive as well as or better than batch-mixed adhesive; also, to evaluate the quality of meter-mixed PR-1860 and PS-875 polysulfide adhesives. These adhesives are candidate replacements for PR-1221 which will not be manufactured in the future. The following material properties were evaluated: peel strength, specific gravity and adhesive components of mixed adhesives, Shore A hardness, tensile adhesion strength, and flow rate. Finally, a visual test called the butterfly test was performed to observe for bubbles and unmixed adhesive. The results of these tests are reported and discussed.

  19. Optimal Meter Placement for Distribution Network State Estimation: A Circuit Representation Based MILP Approach

    DEFF Research Database (Denmark)

    Chen, Xiaoshuang; Lin, Jin; Wan, Can

    2016-01-01

    State estimation (SE) in distribution networks is not as accurate as that in transmission networks. Traditionally, distribution networks (DNs) are lack of direct measurements due to the limitations of investments and the difficulties of maintenance. Therefore, it is critical to improve the accuracy...... of SE in distribution networks by placing additional physical meters. For state-of-the-art SE models, it is difficult to clearly quantify measurements' influences on SE errors, so the problems of optimal meter placement for reducing SE errors are mostly solved by heuristic or suboptimal algorithms...

  20. Automatic Rotational Sky Quality Meter (R-SQM) Design and Software for Astronomical Observatories

    Science.gov (United States)

    Dogan, E.; Ozbaldan, E. E.; Shameoni, Niaei M.; Yesilyaprak, C.

    2016-12-01

    We have presented the new design of Sky Quality Meter (SQM) device that is an automatic rotational model of sky quality meter (R-SQM) carried out by DAG (Eastern Anatolia Observatory) Technical Team. R-SQM is required for determining the long-term changes of sky quality of an astronomical observatory and consists of four SQM devices mounted on a rotating shaft with different angles for scanning all sky. This system is controlled by a Raspberry Pi control card and a step motor with its driver and a special software.