WorldWideScience

Sample records for bruce-6 reactor

  1. The fuel string relocation effect - why the Bruce reactors were derated

    Energy Technology Data Exchange (ETDEWEB)

    Gold, M; Farooqui, M Z; Adebiyi, A S; Chu, R Y; Le, N T; Oliva, A F [Ontario Hydro, Toronto, ON (Canada); Balog, G; Qu, T; DeBuda, P G [Ontario Hydro, Tiverton, ON (Canada). Bruce Nuclear Generating Station-A

    1996-12-31

    In the CANDU Safety Analysis process, a series of design basis accidents are chosen and analyzed to confirm safety system effectiveness. Of all the postulated accidents, the Large Break Loss of Coolant Accident (LBLOCA) - a postulated break in the Heat Transport System piping near a component that services a large number of fuel channels - sets the most demanding requirements on the speed and reactivity depth of the shutdown system devices - shutoff rods and liquid poison injection. While the event is extremely improbable, it is reanalyzed periodically and its consequences examined to ensure continued shutdown system effectiveness. In March 1993, an additional effect was identified: if the break occurred in the piping on the inlet side of the core, this would cause sudden movement of the fuel bundles (so-called fuel string relocation) in a large number of channels. In Ontario Hydro`s Bruce NGS A, Bruce NGS B and Darlington reactors, each channel is fuelled against the flow. In this situation, the relocation of the fuel string results in a sudden positive reactivity increase. This reactivity increase is in addition to the reactivity due to the core coolant voiding. The combined reactivity effect could lead to power pulses much higher than those that would arise due to coolant voiding alone. To maintain safety margins in the event of such a postulated accident, the eight Bruce NGS A and Bruce NGS B units were initially derated to 60 percent power within 2 days of the identification and confirmation of this effect. This paper: describes the fuel string relocation phenomenon in detail; explains why the consequences differ at the various Ontario Hydro reactors; outlines the actions taken with respect to each of the Ontario Hydro reactors in the months following March 1993; describes the design solutions implemented to mitigate the problem and return the Bruce reactors to higher powers. 6 refs., 1 tab., 6 figs.

  2. Flux distribution measurements in the Bruce B Unit 6 reactor using a transportable traveling flux detector system

    International Nuclear Information System (INIS)

    Leung, T.C.; Drewell, N.H.; Hall, D.S.; Lopez, A.M.

    1987-01-01

    A transportable traveling flux detector (TFD) system for use in power reactors has been developed and tested at Chalk River Nuclear Labs. in Canada. It consists of a miniature fission chamber, a motor drive mechanism, a computerized control unit, and a data acquisition subsystem. The TFD system was initially designed for the in situ calibration of fixed self-powered detectors in operating power reactors and for flux measurements to verify reactor physics calculations. However, this system can also be used as a general diagnostic tool for the investigation of apparent detector failures and flux anomalies and to determine the movement of reactor internal components. This paper describes the first successful use of the computerized TFD system in an operating Canada deuterium uranium (CANDU) power reactor and the results obtained from the flux distribution measurements. An attempt is made to correlate minima in the flux profile with the locations of fuel channels so that future measurements can be used to determine the sag of the channels. Twenty-seven in-core flux detector assemblies in the 855-MW (electric) Unit 6 reactor of the Ontario Hydro Bruce B Generating Station were scanned

  3. Flux distribution measurements in the Bruce A unit 1 reactor

    International Nuclear Information System (INIS)

    Okazaki, A.; Kettner, D.A.; Mohindra, V.K.

    1977-07-01

    Flux distribution measurements were made by copper wire activation during low power commissioning of the unit 1 reactor of the Bruce A generating station. The distribution was measured along one diameter near the axial and horizontal midplanes of the reactor core. The activity distribution along the copper wire was measured by wire scanners with NaI detectors. The experiments were made for five configurations of reactivity control mechanisms. (author)

  4. Review of Bruce A reactor regulating system software

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-01

    Each of the four reactor units at the Ontario Hydro Bruce A Nuclear Generating Station is controlled by the Reactor Regulating System (RRS) software running on digital computers. This research report presents an assessment of the quality and reliability of the RRS software based on a review of the RRS design documentation, an analysis of certain significant Event Reports (SERs), and an examination of selected software changes. We found that the RRS software requirements (i.e., what the software should do) were never clearly documented, and that design documents, which should describe how the requirements are implemented, are incomplete and inaccurate. Some RRS-related SERs (i.e., reports on unexpected incidents relating to the reactor control) implied that there were faults in the RRS, or that RRS changes should be made to help prevent certain unexpected events. The follow-up investigations were generally poorly documented, and so it could not usually be determined that problems were properly resolved. The Bruce A software change control procedures require improvement. For the software changes examined, there was insufficient evidence provided by Ontario Hydro that the required procedures regarding change approval, independent review, documentation updates, and testing were followed. Ontario Hydro relies on the expertise of their technical staff to modify the RRS software correctly; they have confidence in the software code itself, even if the documentation is not up-to-date. Ontario Hydro did not produce the documentation required for an independent formal assessment of the reliability of the RRS. (author). 37 refs., 3 figs.

  5. Review of Bruce A reactor regulating system software

    International Nuclear Information System (INIS)

    1995-12-01

    Each of the four reactor units at the Ontario Hydro Bruce A Nuclear Generating Station is controlled by the Reactor Regulating System (RRS) software running on digital computers. This research report presents an assessment of the quality and reliability of the RRS software based on a review of the RRS design documentation, an analysis of certain significant Event Reports (SERs), and an examination of selected software changes. We found that the RRS software requirements (i.e., what the software should do) were never clearly documented, and that design documents, which should describe how the requirements are implemented, are incomplete and inaccurate. Some RRS-related SERs (i.e., reports on unexpected incidents relating to the reactor control) implied that there were faults in the RRS, or that RRS changes should be made to help prevent certain unexpected events. The follow-up investigations were generally poorly documented, and so it could not usually be determined that problems were properly resolved. The Bruce A software change control procedures require improvement. For the software changes examined, there was insufficient evidence provided by Ontario Hydro that the required procedures regarding change approval, independent review, documentation updates, and testing were followed. Ontario Hydro relies on the expertise of their technical staff to modify the RRS software correctly; they have confidence in the software code itself, even if the documentation is not up-to-date. Ontario Hydro did not produce the documentation required for an independent formal assessment of the reliability of the RRS. (author). 37 refs., 3 figs

  6. Power raise through improved reactor inlet header temperature measurement at Bruce A Nuclear Generation Station

    International Nuclear Information System (INIS)

    Basu, S.; Bruggemn, D.

    1997-01-01

    Reactor Inlet Header (RIH) temperature has become a factor limiting the performance of the Ontario Hydro Bruce A units. Specifically, the RIH temperature is one of several parameters that is preventing the Bruce A units from returning to 94% power operation. RIH temperature is one of several parameters which affect the critical heat flux in the reactor channel, and hence the integrity of the fuel. Ideally, RIH temperature should be lowered, but this cannot be done without improving the heat transfer performance of the boilers and feedwater pre-heaters. Unfortunately, the physical performance of the boilers and pre-heaters has decayed and continues to decay over time and as a result the RIH temperature has been rising and approaching its defined limit. With an understanding of the current RIH temperature measurement loop and methods available to improve it, a solution to reduce the measurement uncertainty is presented

  7. The Bruce Energy Centre

    International Nuclear Information System (INIS)

    Jones, R.I.

    1982-06-01

    The Bruce Energy Centre Development Corporation is a joint venture of the Ontario Energy Corporation and 6 private companies formed to market surplus steam from the Bruce Nuclear Power Development. The corporation will also sell or lease land near Bruce NPD. The Bruce Energy Centre has an energy output of 900 BTU per day per dollar invested. Potential customers include greenhouse operators, aquaculturalists, food and beverage manufacturers, and traditional manufacturers

  8. Implementation of a radiological emergency monitoring system for Bruce Power nuclear power plant (Canada); Implementierung eines radiologischen Umgebungsueberwachungsmesssystems fuer das Kernkraftwerk Bruce Power (Kanada)

    Energy Technology Data Exchange (ETDEWEB)

    Madaric, M. [Saphymo GmbH, Frankfurt (Germany)

    2016-07-01

    The Bruce Power nuclear power plant (BP NPP) in Ontario, Canada, is the largest nuclear generating station in the world, operating 8 nuclear reactors producing 6300 MW. In correlation with Bruce Power's safety culture, ''Safety first'' and continuous improvements are essential and substantial parts of the Bruce Power philosophy and management system. After the Fukushima nuclear accident the existing radiological emergency monitoring was analyzed and improved.

  9. Steam generator replacement in Bruce A Unit 1 and Unit 2

    International Nuclear Information System (INIS)

    Hart, R.S.

    2007-01-01

    The Bruce A Generating Station consists of four 900 MW class CANDU units. The reactor and Primary Heat Transport System for each Unit are housed within a reinforced concrete reactor vault. A large duct running below the reactor vaults accommodates the shared fuel handling system, and connects the four reactor vaults to the vacuum building. The reactor vaults, fuelling system duct and the vacuum building constitute the station vacuum containment system. Bruce A Unit 2 was shut down in 1995 and Bruce A Units 1, 3 and 4 were shutdown in 1997. Bruce A Units 3 and 4 were returned to service in late 2003 and are currently operating. Units 1 and 2 remain out of service. Bruce Power is currently undertaking a major rehabilitation of Bruce A Unit 1 and Unit 2 that will extend the in-service tile of these units by at least 25 years. Replacement of the Steam Generators (eight in each unit) is required; this work was awarded to SNC-Lavalin Nuclear (SLN). The existing steam drums (which house the steam separation and drying equipment) will be retained. Unit 2 is scheduled to be synchronized with the grid in 2009, followed by Unit 1 in 2009. Each Bruce A unit has two steam generating assemblies, one located above and to each end of the reactor. Each steam generating assembly consists of a horizontal cylindrical steam drum and four vertical Steam Generators. The vertical Steam Generators connect to individual nozzles that are located on the underside of the Steam Drum (SD). The steam drums are located in concrete shielding structures (steam drum enclosures). The lower sections of the Steam Generators penetrate the top of the reactor vaults: the containment pressure boundary is established by bellows assemblies that connect between the reactor vault roof slab and the Steam Generators. Each Steam Generators is supported from he bottom by a trapeze that is suspended from the reactor vault top structure. The Steam Generator Replacement (SGR) methodology developed by SLN for Unit 1

  10. Steam generator replacement in Bruce A Unit 1 and Unit 2

    International Nuclear Information System (INIS)

    Hart, R.S.

    2006-01-01

    The Bruce A Generating Station consists of four 900 MW class CANDU units. The reactor and Primary Heat Transport System for each Unit are housed within a reinforced concrete reactor vault. A large duct running below the reactor vaults accommodates the shared fuel handling system, and connects the four reactor vaults to the vacuum building. The reactor vaults, fuelling system duct and the vacuum building constitute the station vacuum containment system. Bruce A Unit 2 was shut down in 1995 and Bruce A Units 1, 3 and 4 were shutdown in 1997. Bruce A Units 3 and 4 were returned to service in late 2003 and are currently operating. Units 1 and 2 remain out of service. Bruce Power is currently undertaking a major rehabilitation of Bruce A Unit 1 and Units 2 that will extend the in-service life of these units by at least 25 years. Replacement of the Steam Generators (eight in each unit) is required; this work was awarded to SNC-Lavalin Nuclear (SLN). The existing steam drums (which house the steam separation and drying equipment) will be retained. Unit 2 is scheduled to be synchronized with the grid in 2009, followed by Unit 1 in 2009. Each Bruce A unit has two steam generating assemblies, one located above and to each end of the reactor. Each steam generating assembly consists of a horizontal cylindrical steam drum and four vertical Steam Generators. The vertical Steam Generators connect to individual nozzles that are located on the underside of the Steam Drum (SD). The steam drums are located in concrete shielding structures (steam drum enclosures). The lower sections of the Steam Generators penetrate the top of the reactor vaults: the containment pressure boundary is established by bellows assemblies that connect between the reactor vault roof slab and the Steam Generators. Each Steam Generators is supported from the bottom by a trapeze that is suspended from the reactor vault top structure. The Steam Generator Replacement (SGR) methodology developed by SLN for Unit 1

  11. Responses of platinum, vanadium and cobalt self-powered flux detectors near simulated booster rods in a ZED-2 mockup of a Bruce reactor core

    International Nuclear Information System (INIS)

    French, P.M.; Shields, R.B.; Kroon, J.C.

    1978-02-01

    The static responses of Pt, V and Co self-powered detectors have been compared with copper-foil neutron activation profiles in reference and perturbed Bruce reactor core mockups assembled in the ZED-2 test reactor at Chalk River Nuclear Laboratories. The results indicate that the normalized response of each self-powered detector is an accurate measure of the thermal-neutron flux at locations greater than one lattice pitch from either a booster rod or the core boundary. They indicate that, in the Bruce booster/detector configuration, the normalized static Pt response overestimates the neutron flux by less than 3.5% upon full booster-rod insertion. (author)

  12. AECB staff annual assessment of the Bruce B Nuclear Generating Station for the year 1996

    International Nuclear Information System (INIS)

    1997-06-01

    The Atomic Energy Control Board is the independent federal agency that controls all nuclear activities in Canada. A major use of nuclear energy in Canada is electricity production. The AECB assesses every station's performance against legal requirements, including the conditions in the operating licence. Each station is inspected and all aspects of the station's operation and management is reviewed. This report is the AECB staff assessment of reactor safety at the Bruce Nuclear Generating Station B for 1996. It was concluded that Ontario Hydro operated Bruce B safely in 1996. Although the Bruce B plant is safe,it was noted that the number of outages and the number of secondary and tertiary equipment failures during reactor unit upsets increased. Ontario Hydro needs to pay special attention to prevent such a decrease in the safety performance at Bruce B

  13. CECIL lances Bruce's boilers

    International Nuclear Information System (INIS)

    Malaugh, J.; Monaghan, D.

    1994-01-01

    Over the past few years Ontario Hydro has become increasingly concerned about accumulations of sludge in its nuclear plant boilers, so a comprehensive sludge management programme has been instituted to combat build-up. This included developing the tele-operated robot CECIL (Consolidated Edison Combined Inspection and Lancing) equipment, originally designed for work in PWRs, for CANDU boilers. This required a significantly reconfigured robotic system as well as modifications to the boilers themselves. Work on the Bruce A reactor is described. (4 figures). (author)

  14. Design and verification of computer-based reactor control system modification at Bruce-A candu nuclear generating station

    International Nuclear Information System (INIS)

    Basu, S.; Webb, N.

    1995-01-01

    The Reactor Control System at Bruce-A Nuclear Generating Station is going through some design modifications, which involve a rigorous design process including independent verification and validation. The design modification includes changes to the control logic, alarms and annunciation, hardware and software. The design (and verification) process includes design plan, design requirements, hardware and software specifications, hardware and software design, testing, technical review, safety evaluation, reliability analysis, failure mode and effect analysis, environmental qualification, seismic qualification, software quality assurance, system validation, documentation update, configuration management, and final acceptance. (7 figs.)

  15. Challenges of restarting Bruce Units 3 and 4 from a chemistry and materials perspective

    International Nuclear Information System (INIS)

    Roberts, J.G.; Langguth, K.

    2005-01-01

    In 2001, Bruce Power leased the Bruce Units 1-8 reactors from Ontario Power Generation. Bruce Power decided to restart Bruce Units 3 and 4 following a condition assessment of Bruce A Units 3 and 4. This paper describes the challenges that were encountered and how they were overcome, specifically for heat transport system chemistry in order to adequately protect carbon steel surfaces. The heat transport system, by design, has close inter-relations with other station systems and the related issues of some of these systems are also discussed. Considerations of material impacts have significant influences on the approach to, and control of, chemistry. Specific material impacts led to a novel, and successful, approach. This approach was arrived at following significant efforts by a multi-disciplinary team of operations, maintenance and chemistry staff. The issues, approaches considered and solutions used for a successful outcome will be presented. (author)

  16. Challenges of restarting Bruce Units 3 and 4 from a chemistry and materials perspective

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, J.G.; Langguth, K. [Bruce Power, Tiverton, Ontario (Canada)

    2005-07-01

    In 2001, Bruce Power leased the Bruce Units 1-8 reactors from Ontario Power Generation. Bruce Power decided to restart Bruce Units 3 and 4 following a condition assessment of Bruce A Units 3 and 4. This paper describes the challenges that were encountered and how they were overcome, specifically for heat transport system chemistry in order to adequately protect carbon steel surfaces. The heat transport system, by design, has close inter-relations with other station systems and the related issues of some of these systems are also discussed. Considerations of material impacts have significant influences on the approach to, and control of, chemistry. Specific material impacts led to a novel, and successful, approach. This approach was arrived at following significant efforts by a multi-disciplinary team of operations, maintenance and chemistry staff. The issues, approaches considered and solutions used for a successful outcome will be presented. (author)

  17. Ion chamber repairs in Bruce A

    International Nuclear Information System (INIS)

    Millard, J.; Edwards, T.; Kerker, J.; Pletch, R.; Edwards, T.

    2012-01-01

    This paper discusses identification and successful remediation of leakage of shield tank water on vertical and horizontal Ion Chambers in Bruce A. In doing so, it discusses real events moving from the initial investigation to understand the problem, through looking at options for solutions, and moving to site work and actual resolution.. In multiunit 900 MW class CANDU® reactors, the calandria vessel is suspended within a larger shield tank. Due to temperature changes or changes in moderator fluid levels in the calandria, the calandria can move relative to the shield tank and its reactivity deck. Thimbles which contain the reactivity sensors and controls connect the two vessels and allow the reactivity drives and controls connections to be placed on the deck structure on the top of the reactor assembly for RRS and SDS1 and horizontally for SDS2. These thimbles have expansion joints with metal bellows where they meet the deck structure or shield tank walls. The deck structure lies on a vault containment boundary. The horizontal ion chambers are not in the containment boundary as they connect the outside of the calandria and shield tank around mid plane in the reactor vault, but due to geometry difference provides a more challenging work environment. Bruce had a beetle alarm (1-63851-MIA2-ME30 in alarm state (vertical IC housing)) at the start of April 2012 on Unit 1 channel F vertical Ion chamber expansion joint at the deck connection. This occurred after the moderator levels had been raised after the several years long refurbishment outage and the expansion joint had a significant travel. The investigation showed shield tank water in the collection chamber at the beetle. In addition, Channel J of the horizontal ion chamber had a seized instrument, which on removal was found to relate to oxide build up as a result of minor water leakage into the site. Repairs in both cases were performed as part of the long Bruce 1 & 2 refurbishment outage to completely stop the

  18. RCM: the Bruce B experience

    International Nuclear Information System (INIS)

    Hill, Earl S.; Doyle, E.K.

    1995-01-01

    The use of RCM techniques have begun to change maintenance practice at Bruce B. This paper identifies the status of the program at Bruce B, and examines a new methodology for completing system analysis studies by incorporating lessons learned and results from Bruce A. (author)

  19. AECB staff review of Bruce NGS 'B' operation for the year 1989

    International Nuclear Information System (INIS)

    1990-06-01

    The operation of the Bruce Nuclear Generating Station 'B' is monitored and licensing requirements are enforced by the Atomic Energy Control Board (AECB), which observes operation of the reactors, conducts audits, witnesses important activities, reviews station documentation and reports, and issue approvals, where appropriate, in accordance with licence conditions. This report records the conclusions of the AECB staff assessment of Bruce NGS 'B' during 1989. In general, the station operated within acceptable safety standards. Quality improvement initiatives started in 1989 should lead to improved station maintenance and operation in coming years. Ontario Hydro still needs to improve the administration of operating memos, deficiency reports and call-ups. Station management must ensure that shift supervisors and reactor first operators operate the station in a conservative manner at all times and put safety interests first when responding to a unit upset. (2 tabs.)

  20. Criticality safety issues associated with the introduction of low void reactivity fuel in the Bruce reactors - a management and technical overview

    International Nuclear Information System (INIS)

    Thompson, J.W.; Austman, G.; Iglesias, F.; Schmeing, H.; Elliott, C.; Archinoff, G.

    2004-01-01

    The concept of criticality for operating reactor staff, particularly in a natural uranium-fuelled reactor, is relatively benign - the reactor is controlled at the critical condition by the regulating system. That is, issues related to criticality exist only within the reactor, in a set of carefully managed circumstances. With the introduction of enriched Low Void Reactivity Fuel (LVRF) into this operating environment comes a new 'concept of criticality', one which, although physically the same, cannot be treated in the same fashion. It may be the case that criticality can be achieved outside the reactor, albeit with a set of very pessimistic assumptions. Such 'inadvertent criticality' outside the reactor, should it occur, cannot be controlled. The consequences of such an inadvertent criticality could have far-reaching effects, not only in terms of severe health effects to those nearby, but also in terms of the negative impact on Bruce Power, and the Canadian nuclear industry in general. Thus the introduction of LVRF in the Bruce B reactors, and therefore the introduction of this new hazard, inadvertent criticality, warrants the development of a governance structure for its management. Such a program will consist of various elements, including the establishment of a framework to administer the criticality safety program, analytical assessment to support the process design, the development of operational procedures, the development of enhanced emergency procedures if necessary, and the implementation of a criticality safety training program. The entire package must be sufficient to demonstrate to station management, and the regulator, that the criticality safety risks associated with the implementation of enriched fuel have been properly evaluated, and that all necessary steps have been taken to effectively manage these risks. A well-founded Criticality Safety Program will offer such assurance. In this paper, we describe the establishment of a Criticality Safety

  1. AECB staff annual report of Bruce NGS 'B' for the year 1988

    International Nuclear Information System (INIS)

    1989-05-01

    The operation of the Bruce 'B' Nuclear Generating Station is monitored and licensing requirements are enforced by the Atomic Energy Control Board (AECB) Bruce project staff, with appropriate support from other AECB personnel. The staff observes operation of the reactors, conducts audits, witnesses important activities, reviews station documentation and reports, and issues approvals where appropriate in accordance with license conditions. As required by a condition of its Operating Licence, Ontario Hydro each year submits Technical Reports which summarize various aspects of the operation of Bruce NGS 'B' during the year. When these reports have been reviewed by AECB staff, a formal Annual Review Meeting is held with the station management to discuss safety-related aspects of the station operation, and to inform Ontario Hydro of AECB staff conclusions with respect to the performance of Ontario Hydro in operating the station during the year

  2. Bruce A units 1 and 2 restart project

    International Nuclear Information System (INIS)

    Routledge, K.

    2006-01-01

    This presentation provides an overview of the Bruce A Units 1 and 2 Restart project from the vantage point of the Project Management Contractor (PMC). The presentation will highlight the unique structure of the project, which has been designed to maximize project efficiencies while minimizing the impact to the Bruce Power operational reactors. Efficiency improvements covered in the presentation includes: support services provided to the direct work contractors, radiation protection, worker protection, engineering, field execution, maintenance and facilities. The presentation focusses on the roles of the PMC in helping to ensure the successful outcome of this ambitious reactor refurbishment project. In addition, the Construction Island concept that has been implemented on the project will be presented, with some of the innovative thinking that has gone into its creation. The organization of the PMC and an overview of the project schedule is also presented. AMEC NCL is a privately held consultancy in the Canadian nuclear industry which provides experienced and flexible multi-disciplined resources to support full project management, engineering solutions and safety consultancy services throughout the life cycle of nuclear facilities in Canada, and for customers in related markets in North America and overseas. AMEC NCL is a wholly-owned subsidiary of AMEC plc

  3. Clean energy for a new generation. Steam generator life cycle management and Bruce restart

    International Nuclear Information System (INIS)

    Newman, G.W.

    2009-01-01

    In the mid to late 1990s, Ontario Hydro decided to lay-up and write-down the Bruce A Nuclear Reactors. Upon transition to Bruce Power L.P., Canada's first and only private nuclear operator, new life and prospects were injected into the site, local economy and the provincial energy portfolio. The first step in this provincial power recovery initiative involved restart of Bruce Units 3 and 4 in the 2003/04 time-frame. Units 3 and 4 have performed beyond expectation during the last five-year operating interval. A combination of steam generator and fuel channel issues precluded a similar restart of Units 1 and 2. Enter the refurbishment of Bruce Units 1 and 2. This first-of-a-kind undertaking within the Canadian nuclear power industry is testament to the demonstrated industry leadership by Bruce Power L.P., their investors and the significant vendor community contribution that is supporting this major power infrastructure enhancement. Initiated as a 'turn-key' project solution separated from the operating units, this major refurbishment project has evolved to a fully managed in-house refurbishment project with the continued support from the broader vendor community. As part of this first-of-kind undertaking, Bruce Power L.P. is in the process of accomplishing such initiatives as a complete fuel channel re-tube (i.e. full core calandria and pressure tube replacement), replacement of all boilers (i.e. 16 in total) and the majority of feeder pipe replacement. Complimentary major upgrades and replacement of the remainder of plant equipment including both nuclear and non-nuclear valves, heat exchangers, electrical infrastructure, service water systems and components, all while meeting a parallel evolving/maturing regulatory environment related to achieving compliance with IAEA derived modern codes and standards. Returning to ground level, boiler replacement is a key part of the refurbishment undertaking and this further reflected a meeting of the 'old' and the 'new'. Pre

  4. AECB staff annual assessment of the Bruce A Nuclear Generating Station for the year 1996

    International Nuclear Information System (INIS)

    1997-06-01

    The Atomic Energy Control Board is the independent federal agency that controls all nuclear activities in Canada. A major use of nuclear energy in Canada is electricity production. The AECB assesses every station's performance against legal requirements, including the conditions in the operating licence. Each station is inspected and all aspects of the station's operation and management is reviewed. This report is the AECB staff assessment of reactor safety at the Bruce Nuclear Generating Station A for 1996. Ontario Hydro operated Bruce A safely in 1996, maintaining the risk to workers and the public at an acceptably low level. Special safety system performance at Bruce A was adequate. Availability targets were all met. Improvement is needed to reduce the number of operating licence non-compliances

  5. The operation and maintenance of the SLAR system at Bruce A

    Energy Technology Data Exchange (ETDEWEB)

    Ahuja, S [Ontario Hydro, Tiverton, ON (Canada). Bruce Nuclear Generating Station-A

    1997-12-31

    The SLAR (Spacer Location And Repositioning) system at Bruce A consists of two (2) Delivery Machines and a Fuelling Machine Trolley equipped with the D{sub 2}0 and Air auxiliary systems. The Delivery Machines are designed to perform all the Fuelling Machine operations and have the capability to rapidly defuel/refuel a reactor channel and traverse the SLAR tool to locate and reposition the spacers in the channel. The number of functions that a Delivery Machine must perform makes it more complex as compared to the operations of a Fuelling Machine. The paper discusses the operation of the SLAR Delivery Machines and the problems encountered with the operation and maintenance of this system at Bruce A. (author). 8 figs.

  6. Carsten Niebuhr and James Bruce

    DEFF Research Database (Denmark)

    Friis, Ib

    2013-01-01

    In 1791 Carsten Niebuhr published a review of the first two volumes of Bruce’s Reisen zur Entdeckung der Quellen des Nils (1790). Niebuhr’s strongest criticism of Bruce was that he seemed to have plagiarized some of Niebuhr’s astronomical observations (“adopted them without examination”) and that......In 1791 Carsten Niebuhr published a review of the first two volumes of Bruce’s Reisen zur Entdeckung der Quellen des Nils (1790). Niebuhr’s strongest criticism of Bruce was that he seemed to have plagiarized some of Niebuhr’s astronomical observations (“adopted them without examination...... as written by Bruce in 1770 at Gondar, Abyssinia, contains information about latitudes identical with some of Niebuhr’s observations which were unpublished in 1770; possible explanations for this are proposed. In summary, it seems that Niebuhr is right; it is almost certain that Bruce plagiarized some...

  7. The Bruce nuclear project

    International Nuclear Information System (INIS)

    Rose, J.B.

    1981-01-01

    This case study assesses the industrial relations impact of the construction of the Bruce Nuclear Power Development. It examines the labour relations system in the Ontario electric power sector and in major building construction. Industrial relations problems and practices at the Bruce project are reviewed. The focus of the study is on the relationship between the project and the rest of the Ontario industrial construction industry

  8. Experience of oil in CANDU moderator during A831 planned outage at Bruce Power

    International Nuclear Information System (INIS)

    Ma, G.; Nashiem, R.; Matheson, S.; Stuart, C.; Roberts, J.G.

    2011-01-01

    In their address to the Nuclear Plant Chemistry Conference 2009, Bruce Power staff will describe the effects of oil ingress to the moderator of a CANDU reactor. During the A831 planned outage of Bruce Power Unit 3, an incident of oil ingress into moderator was discovered on Oct 17, 2008. An investigation identified the cause of the oil ingress. Atomic Energy of Canada Ltd. (AECL) assessed operability of the reactor with the oil present and made recommendations with respect to the effect on unit start-up with oil present. The principal concern was the radiolytic generation of deuterium from the breakdown of the oil in-core. Various challenges were presented during start-up which were overcome via innovative approaches. The subsequent actions and consequential effects on moderator chemistry are discussed in this paper. Examination of the plant chemistry data revealed some interesting aspects of moderator system chemistry under upset conditions which will also be presented. (author)

  9. Experience of oil in CANDU® moderator during A831 planned outage at Bruce Power

    International Nuclear Information System (INIS)

    Ma, G.; Nashiem, R.; Matheson, S.; Stuart, C.; Roberts, J.G.

    2010-01-01

    In their address to the Nuclear Plant Chemistry Conference 2009, Bruce Power staff will describe the effects of oil ingress to the moderator of a CANDU® reactor. During the A831 planned outage of Bruce Power Unit 3, an incident of oil ingress into moderator was discovered on Oct 17, 2008. An investigation identified the cause of the oil ingress. Atomic Energy of Canada Ltd. (AECL) assessed operability of the reactor with the oil present and made recommendations with respect to the effect on unit start-up with oil present. The principal concern was the radiolytic generation of deuterium from the breakdown of the oil in-core. Various challenges were presented during start-up which were overcome via innovative approaches. The subsequent actions and consequential effects on moderator chemistry are discussed in this paper. Examination of the plant chemistry data revealed some interesting aspects of moderator system chemistry under upset conditions which will also be presented. (author)

  10. Experience of oil in CANDU® moderator during A831 planned outage at Bruce Power

    Energy Technology Data Exchange (ETDEWEB)

    Ma, G.; Nashiem, R.; Matheson, S. [Bruce Power, Tiverton, Ontario (Canada); Stuart, C. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Roberts, J.G. [CANTECH Associates Ltd., Burlington, Ontario (Canada)

    2010-07-01

    In their address to the Nuclear Plant Chemistry Conference 2009, Bruce Power staff will describe the effects of oil ingress to the moderator of a CANDU® reactor. During the A831 planned outage of Bruce Power Unit 3, an incident of oil ingress into moderator was discovered on Oct 17, 2008. An investigation identified the cause of the oil ingress. Atomic Energy of Canada Ltd. (AECL) assessed operability of the reactor with the oil present and made recommendations with respect to the effect on unit start-up with oil present. The principal concern was the radiolytic generation of deuterium from the breakdown of the oil in-core. Various challenges were presented during start-up which were overcome via innovative approaches. The subsequent actions and consequential effects on moderator chemistry are discussed in this paper. Examination of the plant chemistry data revealed some interesting aspects of moderator system chemistry under upset conditions which will also be presented. (author)

  11. Experience of oil in CANDU moderator during A831 planned outage at Bruce Power

    Energy Technology Data Exchange (ETDEWEB)

    Ma, G.; Nashiem, R.; Matheson, S. [Bruce Power, Tiverton, Ontario (Canada); Stuart, C. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Roberts, J.G. [CANTECH Associates Ltd., Burlington, Ontario (Canada)

    2011-03-15

    In their address to the Nuclear Plant Chemistry Conference 2009, Bruce Power staff will describe the effects of oil ingress to the moderator of a CANDU reactor. During the A831 planned outage of Bruce Power Unit 3, an incident of oil ingress into moderator was discovered on Oct 17, 2008. An investigation identified the cause of the oil ingress. Atomic Energy of Canada Ltd. (AECL) assessed operability of the reactor with the oil present and made recommendations with respect to the effect on unit start-up with oil present. The principal concern was the radiolytic generation of deuterium from the breakdown of the oil in-core. Various challenges were presented during start-up which were overcome via innovative approaches. The subsequent actions and consequential effects on moderator chemistry are discussed in this paper. Examination of the plant chemistry data revealed some interesting aspects of moderator system chemistry under upset conditions which will also be presented. (author)

  12. Ontario Hydro's operating experience with steam generators with specifics on Bruce A and Bruce B problems

    Energy Technology Data Exchange (ETDEWEB)

    Eatock, J W; Patterson, R W [Ontario Hydro, Toronto, ON (Canada); Dyck, R W [Ontario Hydro, Central Production Services Division, Toronto, ON (Canada)

    1991-04-01

    The performance of the steam generators in Ontario Hydro nuclear power stations is reviewed. This performance has generally been outstanding compared to world averages, with very low tube failure and plugging rates. Steam generator problems have made only minor contributions to Ontario Hydro nuclear station incapability factors. The mechanisms responsible for the the observed tube degradation and failures are described. The majority of the leaks have been due fatigue in the U-bend of the Bruce 'A' steam generators. There have been very few failures attributed to corrosion of the three tube materials used in Ontario Hydro steam generators. Recent performance has been deteriorating primarily due to deposit accumulation in the steam generators. Plugging of the broached holes in the upper support plates at Bruce 'A' has caused some derating of two units. Increases have been observed in the primary heat transport system reactor inlet temperature of several units. These increases may be attributed to steam generator tube surface fouling. In addition, several units have accumulated deep, hard sludge piles on the tube sheet, although little damage been observed. Recently some fretting of tubes has been observed at BNGSB in the U-bend support region. Remedial measures are being taken to address the current problems. Solutions are being evaluated to reduce the generation of corrosion products in the feedtrain and their subsequent transport to the steam generators. (author)

  13. Ontario Hydro's operating experience with steam generators with specifics on Bruce A and Bruce B problems

    International Nuclear Information System (INIS)

    Eatock, J.W.; Patterson, R.W.; Dyck, R.W.

    1991-01-01

    The performance of the steam generators in Ontario Hydro nuclear power stations is reviewed. This performance has generally been outstanding compared to world averages, with very low tube failure and plugging rates. Steam generator problems have made only minor contributions to Ontario Hydro nuclear station incapability factors. The mechanisms responsible for the the observed tube degradation and failures are described. The majority of the leaks have been due fatigue in the U-bend of the Bruce 'A' steam generators. There have been very few failures attributed to corrosion of the three tube materials used in Ontario Hydro steam generators. Recent performance has been deteriorating primarily due to deposit accumulation in the steam generators. Plugging of the broached holes in the upper support plates at Bruce 'A' has caused some derating of two units. Increases have been observed in the primary heat transport system reactor inlet temperature of several units. These increases may be attributed to steam generator tube surface fouling. In addition, several units have accumulated deep, hard sludge piles on the tube sheet, although little damage been observed. Recently some fretting of tubes has been observed at BNGSB in the U-bend support region. Remedial measures are being taken to address the current problems. Solutions are being evaluated to reduce the generation of corrosion products in the feedtrain and their subsequent transport to the steam generators. (author)

  14. Business health reporting process at Bruce Power helps drive successful plant performance

    International Nuclear Information System (INIS)

    Krane, J.C.

    2007-01-01

    Developing and implementing consistent and comprehensive measures of performance on a large multi-reactor unit nuclear power plant site is a significant challenge. Linking these performance measures back to licence compliance standards and all aspects of the operations, engineering, maintenance and support activities is needed to ensure cohesive site-wide safe operations and satisfy regulatory needs. At Bruce Power, Canada's largest independently-owned nuclear power producer, a Business Health reporting process has been developed to provide a standardized performance rating scheme. The reporting process ties all self assessment activities to common management principles and process structure areas that comprise the Bruce Power Management System. The principles used for performance ratings link directly back to the operating licenses and the primary referenced management system standard. The Business Health reporting process provides a natural business and regulatory oversight framework report that is easily understood and consistently measured over time. The rating data is derived from easily understood quantitative and qualitative descriptions that can be trended over time. The results derived from semi-annual Business Health reports provide an ongoing overall measure of Bruce Power's management system effectiveness for enabling and sustaining required business results and high standards of safety. (author)

  15. Bruce unit 1 moderator to end shield cooling leak repairs

    Energy Technology Data Exchange (ETDEWEB)

    Boucher, P; Ashton, A [Ontario Hydro, Tiverton, ON (Canada). Bruce Nuclear Generating Station-A

    1996-12-31

    In October 1994, a leak developed between the heavy water Moderator System and the light water End Shield Cooling System at Ontario Hydro`s Bruce A Generating Station Unit 1. The interface between these two systems consists of numerous reactor components all within the reactor vessel. This paper describes the initial discovery and determination of the leak source. The techniques used to pinpoint the leak location are described. The repair strategies and details are outlined. Flushing and refilling of the Moderator system are discussed. The current status of the Unit 1 End Shield Cooling System is given with possible remedial measures for clean-up. Recommendations and observations are provided for future references. (author). 7 figs.

  16. AECB staff annual assessment of the Bruce B Nuclear Generating Station for the year 1994

    International Nuclear Information System (INIS)

    1995-06-01

    AECB staff believes Ontario Hydro operated Bruce B safely in 1994. The Bruce B reactors will remain limited to 88% full power until Ontario Hydro is able to demonstrate that it is safe to operate at higher powers. Ontario Hydro's compliance with AECB regulations and the Operating Licence was satisfactory. AECB found no major violations. The station performance was similar to previous years. Radiation doses to workers and the public were well below the legal limits and also remained below Ontario Hydro's internal targets. Worker radiation doses increased slightly but were comparable to previous years. Inspection of pressure tubes and steam generator tubes by Ontario Hydro showed continuing tube degradation. However, we believe that Ontario Hydro made progress in correcting and managing these problems. Ontario Hydro carried out a full-scale fire drill at Bruce B in 1994. AECB witnessed the drill and were pleased to observe a significant improvement in the station's fire-fighting capability. 7 tabs., 4 figs

  17. Impact of bundle deformation on CHF: ASSERT-PV assessment of extended burnup Bruce B bundle G85159W

    International Nuclear Information System (INIS)

    Rao, Y.F.; Manzer, A.M.

    2005-01-01

    This paper presents a subchannel thermalhydraulic analysis of the effect on critical heat flux (CHF) of bundle deformation such as element bow and diametral creep. The bundle geometry is based on the post-irradiation examination (PIE) data of a single bundle from the Bruce B Nuclear Generating Station, Bruce B bundle G85159W, which was irradiated for more than two years in the core during reactor commissioning. The subchannel code ASSERT-PV IST is used to assess changes in CHF and dryout power due to bundle deformation, compared to the reference, undeformed bundle. (author)

  18. Performance of Bruce natural UO2 fuel irradiated to extended burnups

    International Nuclear Information System (INIS)

    Zhou, Y.N.; Floyd, M.R.; Ryz, M.A.

    1995-11-01

    Bruce-type bundles XY, AAH and GF were successfully irradiated in the NRU reactor at Chalk River Laboratories to outer-element burnups of 570-900 MWh/kgU. These bundles were of the Bruce Nuclear Generating Station (NGS)-A 'first-charge' design that contained gas plenums in the outer elements. The maximum outer-element linear powers were 33-37 kW/m. Post-irradiation examination of these bundles confirmed that all the elements were intact. Bundles XY and AAH, irradiated to outer-element burnups of 570-700 MWh/kgU, experienced low fission-gas release (FGR) ( 500 MWh/kgU (equivalent to bundle-average 450 MWh/kgU) when maximum outer-element linear powers are > 50 kW/m. The analysis in this paper suggests that CANDU 37-element fuel can be successfully irradiated (low-FGR/defect-free) to burnups of at least 700 MWh/kgU, provided maximum power do not exceed 40 kW/m. (author). 5 refs., 1 tab., 8 figs

  19. Review of the reliability of Bruce 'B' RRS dual computer system

    International Nuclear Information System (INIS)

    Arsenault, J.E.; Manship, R.A.; Levan, D.G.

    1995-07-01

    The review presents an analysis of the Bruce 'B' Reactor Regulating System (RRS) Digital Control Computer (DCC) system, based on system documentation, significant event reports (SERs), question sets, and a site visit. The intent is to evaluate the reliability of the RRS DCC and to identify the possible scenarios that could lead to a serious process failure. The evaluation is based on three relatively independent analyses, which are integrated and presented in the form of Conclusions and Recommendations

  20. Innovations in RCM at Bruce B

    International Nuclear Information System (INIS)

    Hill, E.S.; Doyle, E.K.

    1996-01-01

    The use of RCM techniques have begun to change maintenance practice at Bruce B. This paper discusses innovative practices begun recently. Bruce B has decided to evaluate plant systems using different methods based on the effects of system failure. This approach reduces costs, by using a streamlined method, while maintaining the accuracy of analysis. In addition, the approach increases the likelihood that program recommendations will be implemented by the maintenance department by providing maintenance craft with input to the process. Bruce B has also developed techniques to accelerate the analysis process by evaluating analyses performed at other units. These innovations have been successful piloted at the station

  1. Bruce Power - the first 24 exciting months

    International Nuclear Information System (INIS)

    Mottram, R.

    2003-01-01

    In this presentation, Ron Mottram will review the 2 year business evolution since the inception of Bruce Power - Ontario's largest independent electricity generator. Mr. Mottram will provide an overview of the Bruce Power business and operating history, along with specific emphasis on the project to Restart Bruce Units 3 and 4. Ron will share many of the project successes and challenges, and will provide insight into the myriad of issues faced by a large multi-faceted project of this type. (author)

  2. Bruce NGS a loss of flow analysis for effectiveness of level 2 defence-in-depth provisions

    International Nuclear Information System (INIS)

    Won, W.; Jiang, Y.; Kwee, M.; Xue, J.

    2014-01-01

    The concept of defence-in-depth is applied to CANDU (CANada Deuterium Uranium) reactor designs and operations to provide series of levels of defence to prevent accidents progressing and to provide protection for reactor and public safety. The level 2 defence-in-depth provisions are designed to detect and intercept deviation from normal operation in order to prevent anticipated operating occurrences (AOOs) from escalating to accident conditions, and to return the plant to a state of normal operations, according to the Canada Nuclear Safety Commission (CNSC) regulatory document RD-337. Historically, safety analysis has focused on the effectiveness of level 3 defence-in-depth provisions in accident conditions, and the effectiveness of level 2 defence-in-depth has not been assessed. In this study, the effectiveness of Level 2 defence-in-depth is assessed for loss of flow (LOF) events for Bruce Nuclear Generating Station (NGS) A reactors. The level 2 defence-in-depth in Bruce NGS A design is identified to be the stepback function of reactor regulating system (RRS). The behavior of RRS stepback following the initiation of loss of flow event is simulated using RFSP/TUF/RRS - em coupled code. The behavior of full system and single channel is simulated and assessed against the acceptance criteria - fitness for service of systems, structures and components (SSCs). (author)

  3. Bruce NGS a loss of flow analysis for effectiveness of level 2 defence-in-depth provisions

    Energy Technology Data Exchange (ETDEWEB)

    Won, W. [AMEC NSS, Toronto, ON (Canada); Jiang, Y.; Kwee, M.; Xue, J. [Bruce Power, Toronto, ON (Canada)

    2014-07-01

    The concept of defence-in-depth is applied to CANDU (CANada Deuterium Uranium) reactor designs and operations to provide series of levels of defence to prevent accidents progressing and to provide protection for reactor and public safety. The level 2 defence-in-depth provisions are designed to detect and intercept deviation from normal operation in order to prevent anticipated operating occurrences (AOOs) from escalating to accident conditions, and to return the plant to a state of normal operations, according to the Canada Nuclear Safety Commission (CNSC) regulatory document RD-337. Historically, safety analysis has focused on the effectiveness of level 3 defence-in-depth provisions in accident conditions, and the effectiveness of level 2 defence-in-depth has not been assessed. In this study, the effectiveness of Level 2 defence-in-depth is assessed for loss of flow (LOF) events for Bruce Nuclear Generating Station (NGS) A reactors. The level 2 defence-in-depth in Bruce NGS A design is identified to be the stepback function of reactor regulating system (RRS). The behavior of RRS stepback following the initiation of loss of flow event is simulated using RFSP/TUF/RRS{sub -}em coupled code. The behavior of full system and single channel is simulated and assessed against the acceptance criteria - fitness for service of systems, structures and components (SSCs). (author)

  4. Fuel string supporting shield plug (f3sp) for Ontario Hydro - Bruce NGSA

    Energy Technology Data Exchange (ETDEWEB)

    Henry, P T [Canadian General Electric Co. Ltd., Peterborough, ON (Canada)

    1997-12-31

    A reactor `power pulse` problem was identified for the Ontario Hydro Bruce generating stations. On a postulated inlet header break, the fuel strings in a large number of channels could relocate toward the upstream end, resulting in a power pulse. The solution adopted for Bruce GSA is to change the direction of fuelling, from against the flow, to fuelling with the flow. In this revised fuelling scheme, given a postulated inlet header failure, the fuel bundle with the highest burnup would relocate into the reactor core and introduce a negative reactivity during the accident. However, this fuelling configuration results in a highly irradiated fuel bundle residing in the most downstream position against the latch. The latch supports only the outer ring of elements, not the end plate. A resulting high stress on the end plate coupled with high levels of hydrogen and deuterium may result in Zr hydride assisted cracking in the end plate during hot shutdown conditions. (In fuelling against flow, this is not a problem, since the latch supported bundle is not irradiated and has only low levels of hydrogen and deuterium.) A fuel string supporting shield plug (f3sp) which supports the bundle end plate has been developed as a solution to the fuel bundle end plate cracking problem. It would replace the existing outlet shield plug in all channels. This paper will describe the f3sp design, associated fuel handling, operation and qualification for reactor use. (author). 8 figs.

  5. Fuel string supporting shield plug (f3sp) for Ontario Hydro - Bruce NGSA

    International Nuclear Information System (INIS)

    Henry, P.T.

    1996-01-01

    A reactor 'power pulse' problem was identified for the Ontario Hydro Bruce generating stations. On a postulated inlet header break, the fuel strings in a large number of channels could relocate toward the upstream end, resulting in a power pulse. The solution adopted for Bruce GSA is to change the direction of fuelling, from against the flow, to fuelling with the flow. In this revised fuelling scheme, given a postulated inlet header failure, the fuel bundle with the highest burnup would relocate into the reactor core and introduce a negative reactivity during the accident. However, this fuelling configuration results in a highly irradiated fuel bundle residing in the most downstream position against the latch. The latch supports only the outer ring of elements, not the end plate. A resulting high stress on the end plate coupled with high levels of hydrogen and deuterium may result in Zr hydride assisted cracking in the end plate during hot shutdown conditions. (In fuelling against flow, this is not a problem, since the latch supported bundle is not irradiated and has only low levels of hydrogen and deuterium.) A fuel string supporting shield plug (f3sp) which supports the bundle end plate has been developed as a solution to the fuel bundle end plate cracking problem. It would replace the existing outlet shield plug in all channels. This paper will describe the f3sp design, associated fuel handling, operation and qualification for reactor use. (author). 8 figs

  6. Bruce A refurbishment - an update

    International Nuclear Information System (INIS)

    Liddle, R.

    2007-01-01

    Running slightly ahead of schedule on the critical path work, the Bruce A Restart Project has not been without its challenges. About a dozen major contractors with a workforce of 1,700 tradespeople share space inside the Units 1 and 2 Construction Island. They share support services, provided by project management contractor AMEC NCL, and they share the consequences when one part of the project advances ahead of schedule or another falls behind. They also share Bruce Power's safety values and are well on their way to surpassing five-million hours without an acute lost time injury. (author)

  7. Fuel deposits, chemistry and CANDU® reactor operation

    International Nuclear Information System (INIS)

    Roberts, J.G.

    2014-01-01

    'Hot conditioning' is a process which occurs as part of commissioning and initial start-up of each CANDU® reactor, the first being the Nuclear Power Demonstration - 2 reactor (NPD). Later, understanding of the cause of the failure of the Pickering Unit 1 G16 fuel channelled to a revised approach to 'hot conditioning', initially demonstrated on Bruce Unit 5. The difference being that during 'hot conditioning' of CANDU® heat transport systems fuel was not in-core until Bruce Unit 5. The 'hot conditioning' processes will be briefly described along with the consequences to fuel. (author)

  8. Fuel handling solutions to power pulse at Bruce NGS A

    International Nuclear Information System (INIS)

    Day, R.C.

    1996-01-01

    In response to the discovery of the power pulse problem in March of 1993, Bruce A has installed flow straightening shield plugs in the inner zone channels of all units to partially reduce the gap and gain an increase in reactor power to 75%. After review and evaluation of solutions to manage the gap, including creep compensators and long fuel bundles, efforts have focused on a different solution involving reordering the fuel bundles to reverse the burnup profile. This configuration is maintained by fuelling with the flow and providing better support to the highly irradiated downstream fuel bundles by changing the design of the outlet shield plug. Engineering changes to the fuel handling control system and outlet shield plug are planned to be implemented starting in June 1996, thereby eliminating the power pulse problem and restrictions on reactor operating power. (author). 2 refs., 1 tab., 2 figs

  9. Fuel handling solutions to power pulse at Bruce NGS A

    Energy Technology Data Exchange (ETDEWEB)

    Day, R C [Ontario Hydro, Tiverton, ON (Canada). Bruce Nuclear Generating Station-A

    1997-12-31

    In response to the discovery of the power pulse problem in March of 1993, Bruce A has installed flow straightening shield plugs in the inner zone channels of all units to partially reduce the gap and gain an increase in reactor power to 75%. After review and evaluation of solutions to manage the gap, including creep compensators and long fuel bundles, efforts have focused on a different solution involving reordering the fuel bundles to reverse the burnup profile. This configuration is maintained by fuelling with the flow and providing better support to the highly irradiated downstream fuel bundles by changing the design of the outlet shield plug. Engineering changes to the fuel handling control system and outlet shield plug are planned to be implemented starting in June 1996, thereby eliminating the power pulse problem and restrictions on reactor operating power. (author). 2 refs., 1 tab., 2 figs.

  10. GRA model development at Bruce Power

    International Nuclear Information System (INIS)

    Parmar, R.; Ngo, K.; Cruchley, I.

    2011-01-01

    In 2007, Bruce Power undertook a project, in partnership with AMEC NSS Limited, to develop a Generation Risk Assessment (GRA) model for its Bruce B Nuclear Generating Station. The model is intended to be used as a decision-making tool in support of plant operations. Bruce Power has recognized the strategic importance of GRA in the plant decision-making process and is currently implementing a pilot GRA application. The objective of this paper is to present the scope of the GRA model development project, methodology employed, and the results and path forward for the model implementation at Bruce Power. The required work was split into three phases. Phase 1 involved development of GRA models for the twelve systems most important to electricity production. Ten systems were added to the model during each of the next two phases. The GRA model development process consists of developing system Failure Modes and Effects Analyses (FMEA) to identify the components critical to the plant reliability and determine their impact on electricity production. The FMEAs were then used to develop the logic for system fault tree (FT) GRA models. The models were solved and post-processed to provide model outputs to the plant staff in a user-friendly format. The outputs consisted of the ranking of components based on their production impact expressed in terms of lost megawatt hours (LMWH). Another key model output was the estimation of the predicted Forced Loss Rate (FLR). (author)

  11. Bruce nuclear power development (BNPD) postoperational aquatic studies

    International Nuclear Information System (INIS)

    Carey, W.E.

    1984-01-01

    This report summarizes the results of three years of postoperational aquatic study conducted between 1979 and 1981 at the Bruce Nuclear Power Development site. An increase in the rate of organic and inorganic sedimentation during the summer was noted, and was possibly related to construction activity at the Bruce GS 'B' intake site. Vertical thermal stratification persisted later in the year at the 7 m contour of Bruce GS 'A' discharge than at other locations sampled. Water quality conditions reflected the oliogtrophic state of Lake Huron. Several changes were noted in the biotic community. The taxonomic composition of attached algae, zooplankton and benthic macroinvertebrates varied between sampling years. The number of common naids, amphipods and the trichopteran Cheumatopsyche increased substantially in the 1981 rock cage collections. The relative abundance of adult walleye, channel catfish and round whitefish in gill nets increased, with the former two species being more abundant (15 fish per net in September, 1980, and 33 fish per net in July, 1981, respectively) at the 3 m contour of the Bruce GS 'A' discharge transect than at other shoreline sampling locations

  12. AECB assessment of Bruce A comments on the proposed STPA tritium releases

    International Nuclear Information System (INIS)

    Gerdingh, R.F.

    1995-04-01

    In 1993, Ontario Hydro submitted a proposal to the AECB to discharge slightly tritiated water, arising from the steam supplied by Bruce A, through the Steam Transformer Plant A (STPA) discharge lines. The purpose of the proposal is to eliminate the current practice of shipping this water back to Bruce A where it is discharged through the active liquid waste discharge line. One of the STPA lines discharges to the Bruce A intake channel. A small fraction of this water is processed and used as drinking water at Bruce A. At our request, Bruce A management informed Bruce A personnel of the proposal and gave them the opportunity to raise concerns. As part of our evaluation, we assessed those concerns and concluded that they were not an impediment to accept this proposal. This report documents our assessment of the concerns expressed. (author)

  13. AECB assessment of Bruce A comments on the proposed STPA tritium releases

    Energy Technology Data Exchange (ETDEWEB)

    Gerdingh, R F

    1995-04-01

    In 1993, Ontario Hydro submitted a proposal to the AECB to discharge slightly tritiated water, arising from the steam supplied by Bruce A, through the Steam Transformer Plant A (STPA) discharge lines. The purpose of the proposal is to eliminate the current practice of shipping this water back to Bruce A where it is discharged through the active liquid waste discharge line. One of the STPA lines discharges to the Bruce A intake channel. A small fraction of this water is processed and used as drinking water at Bruce A. At our request, Bruce A management informed Bruce A personnel of the proposal and gave them the opportunity to raise concerns. As part of our evaluation, we assessed those concerns and concluded that they were not an impediment to accept this proposal. This report documents our assessment of the concerns expressed. (author).

  14. Development and implementation of the heavy water program at Bruce Power

    International Nuclear Information System (INIS)

    Davloor, R.; Bourassa, C.

    2014-01-01

    Bruce Power operates 8 pressurized heavy water reactor units requiring more than 6000 mega grams (Mg) of heavy water. A Heavy Water Management Program that has been developed to administer this asset over the past 3 years. Through a corporate management system the Program provides governance, oversight and support to the stations. It is implemented through organizational structure, program and procedure documents and an information management system that provides benchmarked metrics, business intelligence and analytics for decision making and prediction. The program drives initiatives such as major maintenance activities, capital programs, detritiation strategies and ensures heavy water systems readiness for outages and rehabilitation of units. (author)

  15. Development and implementation of the heavy water program at Bruce Power

    Energy Technology Data Exchange (ETDEWEB)

    Davloor, R.; Bourassa, C., E-mail: ram.davloor@brucepower.com, E-mail: carl.bourassa@brucepower.com [Bruce Power, Tiverton, ON (Canada)

    2014-07-01

    Bruce Power operates 8 pressurized heavy water reactor units requiring more than 6000 mega grams (Mg) of heavy water. A Heavy Water Management Program that has been developed to administer this asset over the past 3 years. Through a corporate management system the Program provides governance, oversight and support to the stations. It is implemented through organizational structure, program and procedure documents and an information management system that provides benchmarked metrics, business intelligence and analytics for decision making and prediction. The program drives initiatives such as major maintenance activities, capital programs, detritiation strategies and ensures heavy water systems readiness for outages and rehabilitation of units. (author)

  16. Fans af Bruce

    DEFF Research Database (Denmark)

    Vaaben, Nana Katrine

    2007-01-01

    Analysen viser, hvordan det samme ritual under en koncert forener og opdeler de fans, der orienterer sig mod Bruce Springsteen. På den ene side forener ritualet hele publikum i en stor fælles "Intimitet for mange" og på den anden side splitter det dem, fordi det bliver tydeligt, hvem der er de...... rigtige fans, og hvem der tilhører "pøbelen"....

  17. Nuclear process steam for industry: potential for the development of an Industrial Energy Park adjacent to the Bruce Nuclear Power Development

    Energy Technology Data Exchange (ETDEWEB)

    Seddon, W A

    1981-11-01

    This report summarizes the results of an industrial survey jointly funded by the Bruce County Council, the Ontario Energy Corporation, Atomic Energy of Canada Limited and conducted with the cooperation of Ontario Hydro and the Ontario Ministry of Industry and Tourism. The objective of the study was to identify and assess the future needs and interest of energy-intensive industries in the concept of an Industrial Energy Park adjacent tof the Bruce Nuclear Power Development. The proposed Energy Park would capitalize on the infrastructure of the existing CANDU reactors and Ontario Hydro's proven and unique capability to produce steam, as well as electricity, at a cost currently about half that from a comparable coal-fired station.

  18. Bruce A restart (execution and lessons-learned)

    International Nuclear Information System (INIS)

    Soini, J.

    2011-01-01

    Lessons learned with the Bruce Units 3 and 4 restart have been incorporated into the current refurbishment of Units 1 and 2. In addition, lessons learned on the lead unit (U2) are aggressively applied on the lagging unit (U1) to maximize efficiency and productivity. There will be a discussion on how this internal OPEX, along with external lessons learned, are used to continuously improve all aspects of the Bruce A Restart project management cycle, from scope selection, through planning and scheduling, to execution.

  19. Bruce A refurbishment - preparatory work completed, major tasks to begin soon

    International Nuclear Information System (INIS)

    Boyd, F.

    2006-01-01

    Over the past year Bruce Power has been planning and organizing for an extensive refurbishment of the Units 1 and 2 of the Bruce A station. Now the company and its several major contractors are ready to proceed with the most challenging aspects of the actual work. The largest tasks are the replacement of the 8 steam generators and of the 480 complete fuel channels in each unit Bruce Power has created a separate website connected to their basic one to provide ongoing information about the progress of the work. The following brief note is intended to provide an outline of this challenging refurbishment program and to invite readers to visit this website to follow its progress. To provide background the writer was accorded an informative and interesting tour of the units by Rob Liddle, of Bruce Power, on September 28, 2006 the day after the ceremony commemorating the Douglas Point station held at the Bruce site. (author)

  20. Bruce and Darlington power pulse and pressure tube integrity programs -status 1995

    Energy Technology Data Exchange (ETDEWEB)

    Field, G J [Atomic Energy of Canada Ltd., Mississauga, ON (Canada); Wylie, J [Ontario Hydro, Tiverton, ON (Canada). Bruce Nuclear Generating Station-A

    1996-12-31

    The optimum solution to pressure tube fretting at the inlet of the Bruce and Darlington channels, a concern which became very serious following inspections in early 1992, is to remove the inlet bundle and operate with a 12 fuel bundle channel. During analysis of this operating mode a `power pulse` was identified which could occur during an inlet header break where all the fuel in the channel moved rapidly to the inlet of the channel. The pulse was unacceptable and the units were derated until solutions could be implemented. A number of solutions were identified and each station has begun implementation of their specific solution. Implementation has not been without problems and this paper provides a status report on the progress to date of the long bundle implementation solution for Bruce B and Darlington and the fuelling with the flow solution being implemented at Bruce A. Both types of solution have a significant impact on the original concern, fretting of the pressure tube. (author). 1 ref., 6 figs.

  1. Improved synthesis of (3E,6Z,9Z)-1,3,6,9-nonadecatetraene, attraction inhibitor of bruce spanworm, Operophtera bruceata, to pheromone traps for monitoring winter moth, Operophtera brumata.

    Science.gov (United States)

    Khrimian, Ashot; Lance, David R; Mastro, Victor C; Elkinton, Joseph S

    2010-02-10

    The winter moth, Operophtera brumata (Lepidoptera: Geometridae), is an early-season defoliator that attacks a wide variety of hardwoods and, in some cases, conifers. The insect is native to Europe but has become established in at least three areas of North America including southeastern New England. The female-produced sex attractant pheromone of the winter moth was identified as (3Z,6Z,9Z)-1,3,6,9-nonadecatetraene (1), which also attracts a native congener, the Bruce spanworm, Operophtera bruceata . Dissection, or (for certainty) DNA molecular testing, is required to differentiate between males of the two species. Thus, a trapping method that is selective for winter moth would be desirable. A geometric isomer of the pheromone, (3E,6Z,9Z)-1,3,6,9-nonadecatetraene (2), can reportedly inhibit attraction of Bruce spanworm to traps without affecting winter moth catch, but use of the pheromone and inhibitor together has not been optimized, nor has the synthesis of the inhibitor. This paper presents two new syntheses of the inhibitor (3E,6Z,9Z)-1,3,6,9-nonadecatetraene based on the intermediate (3Z,6Z)-3,6-hexadecadien-1-ol (4), which has also been utilized in the synthesis of the pheromone. The syntheses combine traditional acetylenic chemistry and Wittig olefination reactions. In one approach, 2 was synthesized in 80% purity (20% being pheromone 1), and in the second, tetraene 2 of 96% purity (and free of 1) was produced in 25% overall yield from dienol 4. The last method benefitted from a refined TEMPO-mediated PhI(OAc)(2) oxidation of 4 and a two-carbon homologation of the corresponding aldehyde 7.

  2. Fuel deposits, chemistry and CANDU reactor operation

    International Nuclear Information System (INIS)

    Roberts, J.G.

    2013-01-01

    'Hot conditioning' is a process which occurs as part of commissioning and initial start-up of each CANDU reactor, the first being the Nuclear Power Demonstration-2 reactor (NPD). Later, understanding of the cause of the failure of the Pickering Unit 1 G16 fuel channel led to a revised approach to 'hot conditioning', initially demonstrated on Bruce Unit 5, and subsequently utilized for each CANDU unit since. The difference being that during 'hot conditioning' of CANDU heat transport systems fuel was not in-core until Bruce Unit 5. The 'hot conditioning' processes will be briefly described along with the consequences to fuel. (author)

  3. Steam generator tubesheet waterlancing at Bruce B

    Energy Technology Data Exchange (ETDEWEB)

    Persad, R. [Babcock and Wilcox Canada, Cambridge, Ontario (Canada); Eybergen, D. [Bruce Power, Tiverton, Ontario (Canada)

    2006-07-01

    High pressure water cleaning of steam generator secondary side tubesheet surfaces is an important and effective strategy for reducing or eliminating under-deposit chemical attack of the tubing. At the Bruce B station, reaching the interior of the tube bundle with a high-pressure water lance is particularly challenging due to the requirement to setup on-boiler equipment within the containment bellows. This paper presents how these and other design constraints were solved with new equipment. Also discussed is the application of new high-resolution inter-tube video probe capability to the Bruce B steam generator tubesheets. (author)

  4. Fuel bundle to pressure tube fretting in Bruce and Darlington

    Energy Technology Data Exchange (ETDEWEB)

    Norsworthy, A G; Ditschun, A [Atomic Energy of Canada Ltd., Mississauga, ON (Canada)

    1996-12-31

    As the fuel channel elongates due to creep, the fuel string moves relative to the inlet until the fuel pads at the inboard end eventually separate from the spacer sleeve, and the fuel resides on the burnish mark of the pressure tube. The bundle is then supported in a fashion which contributes to increased levels of vibration. Those pads which (due to geometric variation) have contact loads with the pressure tube within a certain range, vibrate, and cause significant fretting on the burnish mark, and further along at the midplane of the bundle. Inspection of the pressure tubes in Bruce A, Bruce B, and Darlington has revealed fret damage up to 0.55 mm at the burnish mark and slightly lower than this at the inlet bundle midplane. To date, all fret marks have been dealt with successfully without the need for tube replacement, but a program of work has been initiated to understand the mechanism and reduce the fretting. Such understanding is necessary to guide future design changes to the fuel bundle, to guide future inspection programs, to guide maintenance programs, and for longer term strategic planning. This paper discusses how the understanding of fretting has evolved and outlines a current hypothesis for the mechanism of fretting. The role of bundle geometry, excitation forces, and reactor conditions are reviewed, along with options under consideration to mitigate damage. (author). 4 refs., 2 tabs., 13 figs.

  5. Fuel bundle to pressure tube fretting in Bruce and Darlington

    International Nuclear Information System (INIS)

    Norsworthy, A.G.; Ditschun, A.

    1995-01-01

    As the fuel channel elongates due to creep, the fuel string moves relative to the inlet until the fuel pads at the inboard end eventually separate from the spacer sleeve, and the fuel resides on the burnish mark of the pressure tube. The bundle is then supported in a fashion which contributes to increased levels of vibration. Those pads which (due to geometric variation) have contact loads with the pressure tube within a certain range, vibrate, and cause significant fretting on the burnish mark, and further along at the midplane of the bundle. Inspection of the pressure tubes in Bruce A, Bruce B, and Darlington has revealed fret damage up to 0.55 mm at the burnish mark and slightly lower than this at the inlet bundle midplane. To date, all fret marks have been dealt with successfully without the need for tube replacement, but a program of work has been initiated to understand the mechanism and reduce the fretting. Such understanding is necessary to guide future design changes to the fuel bundle, to guide future inspection programs, to guide maintenance programs, and for longer term strategic planning. This paper discusses how the understanding of fretting has evolved and outlines a current hypothesis for the mechanism of fretting. The role of bundle geometry, excitation forces, and reactor conditions are reviewed, along with options under consideration to mitigate damage. (author). 4 refs., 2 tabs., 13 figs

  6. David Bruce Payton : väikeriigid mõistavad üksteist / David Bruce Payton ; interv. Marianne Mikko

    Index Scriptorium Estoniae

    Payton, David Bruce

    2003-01-01

    Uus-Meremaa suursaadik Eestis David Bruce Payton talupidaja toetamise loobumisest Uus-Meremaal, Uus-Meremaa põllumajandussektorist, veinidest, ekspordist, Eesti saamisest EL-i ja NATO liikmeks, Uus-Meremaa rahvastikust, elatustasemest, Iraagi võimalikust ründamisest, Põhja-Koreast

  7. Bruce Springsteen as a Symbol

    DEFF Research Database (Denmark)

    Gitz-Johansen, Thomas

    2018-01-01

    The article explores how Bruce Springsteen and his music function as a symbol. The article first presents the Jungian theory of symbols and of music as symbol. The central argument of the article is that, by functioning symbolically, Springsteen has the potential to influence the psyche of his au...

  8. Fuel channel design improvements for large CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Villamagna, A; Price, E G; Field, G J [Atomic Energy of Canada Ltd., Mississauga, ON (Canada)

    1996-12-31

    From the initial designs used in NPD and Douglas point reactors, the CANDU fuel channel and its components have undergone considerable development. Two major designs have evolved: the Pickering/CANDU 6 design which has 12 fuel bundles in the core and where the new fuel is inserted into the inlet end, and the Bruce/Darlington design which has 13 bundles in the channel and where new fuel is inserted into the outlet end. In the development of a single unit CANDU reactor of the size of a Bruce or Darlington unit which would use a Darlington design calandria, the decision has been made to use the CANDU 6 fuel channel rather than the Darlington design. The CANDU 6 channel has provided excellent performance and will not encounter the degree of maintenance required for the Bruce/Darlington design. The channel design in turn influences the fuelling machine/fuel handling concepts required. The changes to the CANDU 6 fuel channel design to incorporate it in the large unit are small. In fact, the changes that are proposed relate to the desire to increase margins between pressure tube properties and design conditions or ameliorate the consequences of postulated accident conditions, rather than necessary adaptation to the larger unit. Better properties have been achieved in the pressure tube material resulting from alloy development program over the past 10 years. Pressure tubes can now he made with very low hydrogen concentrations so that the hydrogen picked up as deuterium will not exceed the terminal solid solubility for the in-core region in 30 years. The improvements in metal chemistry allow the production of high toughness tubes that retain a high level of toughness during service. A small increase in wall thickness will reduce the dimensional changes without significantly affecting burnup. Changes to increase safety margins from postulated accidents are concentrated on containing the consequences of pressure tube damage. The changes are concentrated on the calandria tube

  9. Safety benefits from CANDU reactor replacement - a case study

    International Nuclear Information System (INIS)

    Mottram, R.; Millard, J.W.F.; Purdy, P.

    2011-01-01

    Both total core replacement and core retubing have been used in the CANDU industry. For future plant refurbishments, based on experience both in new construction and in recent refurbishments, the concept of total core replacement has been revisited. This builds on practices for replacement of other large plant equipment like boilers. The Bruce CANDU reactors, with their local shield tanks built around the Calandria and containment closely located around that Calandria Shield Tank Assembly (CSTA), are believed to be good candidates for core replacement. A structured process was used to design a replacement CSTA suitable for Bruce A use. The work started with a study of opportunities for safety enhancements in the core. This progressed into design studies and related design assist safety analysis on the reactor. A key element of the work involved consideration of how verified features from later CANDU designs, and from our new reactor design work, could be tailored to fit this replacement core. The replacement reactor core brings in structural improvements in both calandria and end shield, and safety improvements like the natural circulation enhancing moderator cooling layout and further optimized reactivity layouts to improve shutdown system performance. Bruce Power are currently studying the business implications of this and retube techniques as part of preparation for future refurbishments. The work explained in this paper is in the context of the safety related changes and the work to choose and quantify them. (author)

  10. Safety benefits from CANDU reactor replacement. A case study

    International Nuclear Information System (INIS)

    Mottram, R.; Millard, J.W.F.; Purdy, P.

    2011-01-01

    Both total core replacement and core retubing have been used in the CANDU industry. For future plant refurbishments, based on experience both in new construction and in recent refurbishments, the concept of total core replacement has been revisited. This builds on practices for replacement of other large plant equipment like boilers. The Bruce CANDU reactors, with their local shield tanks built around the Calandria and containment closely located around that Calandria Shield Tank Assembly (CSTA), are believed to be good candidates for core replacement. A structured process was used to design a replacement CSTA suitable for Bruce A use. The work started with a study of opportunities for safety enhancements in the core. This progressed into design studies and related design assist safety analysis on the reactor. A key element of the work involved consideration of how verified features from later CANDU designs, and from our new reactor design work, could be tailored to fit this replacement core. The replacement reactor core brings in structural improvements in both calandria and end shield, and safety improvements like the natural circulation enhancing moderator cooling layout and further optimized reactivity layouts to improve shutdown system performance. Bruce Power are currently studying the business implications of this and retube techniques as part of preparation for future refurbishments. The work explained in this paper is in the context of the safety related changes and the work to choose and quantify them. (author)

  11. Structural and metamorphic evolution of the Mid-Late Proterozoic Rayner Complex, Cape Bruce, East Antarctica

    International Nuclear Information System (INIS)

    Dunkley, D.J.; Clarke, G.L.; White, R.W.

    2002-01-01

    Granulite to transitional granulite facies gneisses exposed at Cape Bruce, Rayner Complex, East Antarctica, record three main orogenic/magmatic phases: (1) intrusion of c. 1000-980 Ma felsic orthogneisses into Mid-Proterozoic metasediments, contemporary with the development of north-trending reclined to recumbent folds; (2) extensive c. 980-900 Ma felsic magmatism, including equivalents of the Mawson Charnockite, which accompanied the development of upright, east-northeast-trending folds; and (3) ultramylonite zones of uncertain age. The first two phases are known as the Rayner Structrual Episode, the effects of which are similar in rocks to the east of Cape Bruce, at Mawson, and in the northern Prince Charles Mountains. Archaean rocks immediately to the west of Cape Bruce were tectonically reworked during the Rayner Structural Episode. The first orogenic phase is inferred to represent the collision between a wedge-shaped Proterozoic block comprising rocks of the Mawson Coast and Eastern Ghats Province, with the Archaean Napier Complex. The second orogenic phase included a major period of crustal growth through emplacement of the Mawson Charnockite and equivalents. (author). 41 refs., 6 figs., 1 tab

  12. Universal delivery machine - design of the Bruce and Darlington heads

    International Nuclear Information System (INIS)

    Gray, M.G.; Brown, R.

    2003-01-01

    The Universal Delivery Machine (UDM) was designed and supplied to reduce the time required to perform channel inspection services. The Bruce UDM was the first to be completed followed by Pickering and Darlington. The Bruce and Darlington machines are nearly identical. Design concepts applied include a rotating, multiple tool station magazine, a rigid chain driving telescoping rams, a common drive package, and an external support frame to meet seismic qualification requirements. (author)

  13. Bruce used fuel dry storage project evolution from Pickering to Bruce

    International Nuclear Information System (INIS)

    Young, R.E.

    1996-01-01

    Additional fuel storage capacity is required at Bruce Nuclear Generating Station, which otherwise would soon fill up all its pool storage capacity. The recommended option was to use a dry storage container similar to that at Pickering. The changes made to the Pickering type of container included: fuel to be stored in trays; the container's capacity increased to 600 bundles; the container's lid to be changed to a metal one; the single concrete lid to be changed to a double metal lid system; the container not to be transportable; the container would be dry-loaded. 7 figs

  14. Bruce used fuel dry storage project evolution from Pickering to Bruce

    Energy Technology Data Exchange (ETDEWEB)

    Young, R E [Ontario Hydro, Tiverton, ON (Canada). Bruce Nuclear Generating Station-A

    1997-12-31

    Additional fuel storage capacity is required at Bruce Nuclear Generating Station, which otherwise would soon fill up all its pool storage capacity. The recommended option was to use a dry storage container similar to that at Pickering. The changes made to the Pickering type of container included: fuel to be stored in trays; the container`s capacity increased to 600 bundles; the container`s lid to be changed to a metal one; the single concrete lid to be changed to a double metal lid system; the container not to be transportable; the container would be dry-loaded. 7 figs.

  15. Instrument calibration optimization at Bruce Power: ECI loops

    International Nuclear Information System (INIS)

    Chugh, V.; Angelova, M.; Ghias, S.; Parmar, R.; Wang, V.; Xie, H.; Higgs, J.; Schut, J.; Cruchley, I.

    2011-01-01

    Most instruments in a nuclear power plant are calibrated at regular intervals to ensure consistency with the assumptions in the plant Technical Specifications and/or Safe Operating Envelope (SOE) compliance limits (e.g., As-Found Tolerance). In the Instrument Uncertainty Calculations (IUC), As-Found Tolerance for instrument drift is estimated based on statistical analysis of As-Found and As-Left calibration data such as that carried out for Bruce NGS by EPRI (Electric Power Research Institute) in 1998. Bruce specific drift values were found to compare favorably with industry benchmarks. Recently a significant amount of work has been done by EPRI and IAEA (International Atomic Energy Agency) on extending calibration intervals of safety related instruments. Reduction in calibration frequency reduces time commitments on the part of Authorized Nuclear Operators and safety system qualified Control Maintenance Technicians, and allows more schedule flexibility. To establish the proof of concept, As-Left/As-Found tolerances and available margins have been evaluated for the Bruce B Emergency Coolant Injection (ECI) system instrument loops to determine whether an extension of the calibration period from one or two year to three years is justifiable on the basis that these loops will still be in compliance with SOE. The analysis showed that 60% of instruments in the ECI system are qualified for calibration interval extension up to three years. Sensitivity assessment of the effect of proposed changes in calibration intervals for 60% of the instruments on the ECI system unavailability has also been performed using the current Bruce Power ECI unavailability model. The results show that, the largest ECI Predicted Future Unavailability (PFU) is 9.2E-4 year/year for in-core LOCA accident. This value is still below the target unavailability of 1.0E-3 year/year. (author)

  16. Instrument calibration optimization at Bruce Power: ECI loops

    Energy Technology Data Exchange (ETDEWEB)

    Chugh, V.; Angelova, M.; Ghias, S.; Parmar, R.; Wang, V.; Xie, H. [AMEC NSS, Toronto, Ontario (Canada); Higgs, J.; Schut, J.; Cruchley, I. [Bruce Power, Tiverton, Ontario (Canada)

    2011-07-01

    Most instruments in a nuclear power plant are calibrated at regular intervals to ensure consistency with the assumptions in the plant Technical Specifications and/or Safe Operating Envelope (SOE) compliance limits (e.g., As-Found Tolerance). In the Instrument Uncertainty Calculations (IUC), As-Found Tolerance for instrument drift is estimated based on statistical analysis of As-Found and As-Left calibration data such as that carried out for Bruce NGS by EPRI (Electric Power Research Institute) in 1998. Bruce specific drift values were found to compare favorably with industry benchmarks. Recently a significant amount of work has been done by EPRI and IAEA (International Atomic Energy Agency) on extending calibration intervals of safety related instruments. Reduction in calibration frequency reduces time commitments on the part of Authorized Nuclear Operators and safety system qualified Control Maintenance Technicians, and allows more schedule flexibility. To establish the proof of concept, As-Left/As-Found tolerances and available margins have been evaluated for the Bruce B Emergency Coolant Injection (ECI) system instrument loops to determine whether an extension of the calibration period from one or two year to three years is justifiable on the basis that these loops will still be in compliance with SOE. The analysis showed that 60% of instruments in the ECI system are qualified for calibration interval extension up to three years. Sensitivity assessment of the effect of proposed changes in calibration intervals for 60% of the instruments on the ECI system unavailability has also been performed using the current Bruce Power ECI unavailability model. The results show that, the largest ECI Predicted Future Unavailability (PFU) is 9.2E-4 year/year for in-core LOCA accident. This value is still below the target unavailability of 1.0E-3 year/year. (author)

  17. Bruce A - performance power

    Energy Technology Data Exchange (ETDEWEB)

    Boucher, P. [Bruce Power, Tiverton, ON (Canada)

    2015-07-01

    This paper discusses the strategy for improving performance at Bruce Power. The key to excellence is changing behaviours. Reinforcing and enforcing expectations, aligned with the 2015 operating to the Highest Standards Site Initiative. Long term equipment strategies, supported by the 2015 Equipment Health Site Initiative, individual and group accountability for online/outage Work Management, with further gains through 2015 Maintenance Alignment and Resource Strategy (MARS) Site Initiative. Results showed human performance improvement, more reliable and predictable units and outage performance improvement.

  18. The Bruce Medalists

    Science.gov (United States)

    Tenn, J. S.

    2001-12-01

    The Astronomical Society of the Pacific (ASP) has presented the Catherine Wolfe Bruce gold medal for lifetime contributions to astronomy most years since 1898. The 94 medalists include most of the scientists whose work has greatly changed astronomy since the late nineteenth century: Huggins, Pickering, Campbell, Hale, Eddington, Russell, Adams, Slipher, Hertzsprung, Hubble, Shapley, Oort, Baade, ... Major exceptions include those who died young, those who worked in teams, and, in the early years, women. Mathematicians appear to have been as likely to be honored as astronomers from the beginning, but the fortunes of physicist nominees have varied. The nomination process is an unusual one, with the directors of six observatories, three in the U.S. and three abroad, asked to nominate up to three candidates each year. For the first six decades the observatories rarely varied, and directors had long tenures. They nominated the same individuals repeatedly. Now both observatories and their directors vary regularly. Much can be learned about the changes in astronomy from the late nineteenth century, when observers worked alone with long refractors and a theorist could spend a lifetime computing the orbit of one comet, to the present, when most papers have multiple authors and a single project may include millions of objects. For example, celestial mechanics was the specialty of many of the early medalists but none since 1966. I have posted photographs, brief biographies, extensive bibliographies, and links to publications by and about all of the medalists, from Simon Newcomb in 1898 to Hans Bethe in 2001, at http://phys-astro.sonoma.edu/BruceMedalists/. I will discuss a bit of the history of the medal and some of the medalists.

  19. ROP design for Enhanced CANDU 6 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Hu, J.; Scherbakova, D; Kastanya, D.; Ovanes, M. [Candu Energy Inc., Mississauga, Ontario (Canada)

    2011-07-01

    The Enhanced CANDU 6 (EC6) nuclear power plant is a mid-sized pressurized heavy water reactor design, based on the highly successful CANDU 6 (C6) family of power plants, upgraded to meet today's Canadian and international safety requirements and to satisfy Generation III expectations. The EC6 reactor is equipped with two independent Regional Overpower Protection (ROP) systems to prevent overpowers in the reactor fuel. The ROP system design, retaining the traditional C6 methodology, is determined to cover the End-of-Life (EOL) reactor core condition since the reactor operating/thermal margin gradually decreases as plant equipment ages. Several design changes have been incorporated into the reference C6 plant to mitigate the ageing effect on the ROP trip margin. This paper outlines the basis for the EC6 ROP physics design and presents the ROP related improvements made in the EC6 design to ensure that full power operation is not limited by the ROP throughout the entire life of the reactor. (author)

  20. Non intrusive check valve diagnostics at Bruce A

    International Nuclear Information System (INIS)

    Marsch, S.P.

    1997-01-01

    Bruce A purchased non intrusive check valve diagnostic equipment in 1995 to ensure operability and availability of critical check valves in the Station. Diagnostics can be used to locate and monitor check valve degradation modes. Bruce A initiated a pilot program targeting check valves with flow through them and ones that completed open or close cycles. Approaches to determine how to confirm operability of passive check valves using non intrusive techniques were explored. A sample population of seventy-three check valves was selected to run the pilot program on prior to complete implementation. The pilot program produced some significant results and some inconclusive results. The program revealed a major finding that check valve performance modeling is required to ensure continuous operability of check valves. (author)

  1. Non intrusive check valve diagnostics at Bruce A

    Energy Technology Data Exchange (ETDEWEB)

    Marsch, S.P. [Ontario Hydro, Bruce Nuclear Generating Station A, Tiverton, ON (Canada)

    1997-07-01

    Bruce A purchased non intrusive check valve diagnostic equipment in 1995 to ensure operability and availability of critical check valves in the Station. Diagnostics can be used to locate and monitor check valve degradation modes. Bruce A initiated a pilot program targeting check valves with flow through them and ones that completed open or close cycles. Approaches to determine how to confirm operability of passive check valves using non intrusive techniques were explored. A sample population of seventy-three check valves was selected to run the pilot program on prior to complete implementation. The pilot program produced some significant results and some inconclusive results. The program revealed a major finding that check valve performance modeling is required to ensure continuous operability of check valves. (author)

  2. An Appreciation of the Scientific Life and Acheivements of Bruce Merrifield

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, R

    2007-06-15

    Bruce Merrifield's scientific biography, 'Life During a Golden Age of Peptide Chemistry: The Concept and Development of Solid-Phase Peptide Synthesis', provides a history of solid phase-peptide synthesis (SPPS) from 1959 to 1993 [1]. While many readers will be familiar with SPPS literature after 1963, the inclusion of unpublished material from Merrifield's early laboratory notebooks opens a fascinating window on the development of SPPS from the formulation of concept in 1959 (p. 56, ref. 1) to the synthesis of a tetrapeptide four years later [2]. This early period was characterized by slow progress interrupted by numerous setbacks that led Bruce to later record (p. 90, ref. 1): 'At the end of the first two years the results were so poor, I wonder what made me think that this approach would ever succeed; but from the outset I had a strong conviction that this was a good idea, and I am glad that I stayed with it long enough'. Garland Marshall, Bruce's first graduate student (1963-1966), as well as later colleagues, were essentially unaware of the many highways, byways and dead ends that Bruce had explored in the early years [3].

  3. Bruce NGS A Unit 4 preheater divider plate failure

    International Nuclear Information System (INIS)

    Landridge, M.; McInnes, D.

    1995-01-01

    On May 19, 1995, without any prior operational indications, Bruce A discovered preheater divider plate damage in Unit 4 that had the potential to have a major impact on the continued safe operation of the station. Further investigations indicated that Unit 4 may have been operating with this damage for as long as ten years. In the two months following the discovery, Bruce A has procured and replaced the 4 divider plates, located most of the missing pieces, retrieved pieces from the PHT system, investigated historical operational information, performed detailed analytical investigations, investigated root cause, performed in-situ and mock-up testing, updated operational procedures and installed DP monitoring equipment

  4. AECB staff annual assessment of the Bruce A Nuclear Generating Station for the year 1995

    International Nuclear Information System (INIS)

    1996-06-01

    The Atomic Energy Control Board conducts a staff assessment of safety at Bruce Nuclear Generating Station A for 1995. On-site Project Officers and Ottawa based specialists monitored the station throughout the year. Ontario Hydro operated Bruce A safely in 1995, maintaining the risk to workers and the public at an acceptably low level. Radiation doses to workers and releases to the environment were well below regulatory limits. However, Ontario Hydro must improve contamination control at Bruce A. Special safety system performance a Bruce A was less than adequate. The negative pressure containment system and units 4's shutdown system two exceeded unavailability targets in 1995. However, we are satisfied Ontario Hydro is taking appropriate action to correct this. 5 tabs., 5 figs

  5. Bruce Power's nuclear pressure boundary quality assurance program requirements, implementation and transition

    International Nuclear Information System (INIS)

    Krane, J.C.

    2009-01-01

    The development of a full scope nuclear pressure boundary quality assurance program in Canada requires extensive knowledge of the structure and detailed requirements of codes and standards published by the Canadian Standards Association (CSA) and American Society of Mechanical Engineers (ASME). Incorporation into company governance documents and implementation of these requirements while managing the transition to more recent revisions of these codes and standards represents a significant challenge for Bruce Power, Canada's largest independent nuclear operator. This paper explores the key developments and innovative changes that are used to ensure successful regulatory compliance and effective implementation of the Bruce Power Pressure Boundary Quality Assurance Program. Challenges and mitigating strategies to sustain this large compliance based program at Bruce Power's 8 unit nuclear power plant site will also be detailed. (author)

  6. Chemistry control at Bruce NGS 'B' from constructed to commercial operation

    International Nuclear Information System (INIS)

    Roberts, J.G.

    1987-01-01

    Pre-operational storage chemistry and flushing of the secondary side is described. The approach devised for Bruce NGS 'B' Unit 6 was unique for an Ontario Hydro Nuclear Unit. The significance of the improved Construction installation and Quality Assurance procedures, combined with those of Operations is identified. Secondary side chemistry during both commissioning and later operation is reported. It will be shown that the application of ALARA (As Low As is Reasonably Achievable) concept has resulted in tighter chemical specifications being met

  7. Exercise testing of pre-school children using the Bruce treadmill protocol: new reference values

    NARCIS (Netherlands)

    M.H.M. van der Cammen-van Zijp (Monique); H. IJsselstijn (Hanneke); T. Takken (Tim); S.P. Willemsen (Sten); D. Tibboel (Dick); H.J. Stam (Henk); H.J.G. van den Berg-Emons (Rita)

    2010-01-01

    textabstractThe Bruce treadmill protocol is an often-used exercise test for children and adults. Few and mainly old normative data are available for young children. In this cross-sectional observational study we determined new reference values for the original Bruce protocol in children aged 4 and 5

  8. Geoscientific Characterization of the Bruce Site, Tiverton, Ontario

    Science.gov (United States)

    Raven, K.; Jackson, R.; Avis, J.; Clark, I.; Jensen, M.

    2009-05-01

    Ontario Power Generation is proposing a Deep Geologic Repository (DGR) for the long-term management of its Low and Intermediate Level Radioactive Waste (L&ILW) within a Paleozoic-age sedimentary sequence beneath the Bruce site near Tiverton, Ontario, Canada. The concept envisions that the DGR would be excavated at a depth of approximately 680 m within the Ordovician Cobourg Formation, a massive, dense, low- permeability, argillaceous limestone. Characterization of the Bruce site for waste disposal is being conducted in accordance with a four year multi-phase Geoscientific Site Characterization Plan (GSCP). The GSCP, initially developed in 2006 and later revised in 2008 to account for acquired site knowledge based on successful completion of Phase I investigations, describes the tools and methods selected for geological, hydrogeological and geomechanical site characterization. The GSCP was developed, in part, on an assessment of geoscience data needs and collection methods, review of the results of detailed geoscientific studies completed in the same bedrock formations found off the Bruce site, and recent international experience in geoscientific characterization of similar sedimentary rocks for long-term radioactive waste management purposes. Field and laboratory work related to Phase 1 and Phase 2A are nearing completion and have focused on the drilling, testing and monitoring of four continuously cored vertical boreholes through Devonian, Silurian, Ordovician and Cambrian bedrock to depths of about 860 mBGS. Work in 2009 will focus on drilling and testing of inclined boreholes to assess presence of vertical structure. The available geological, hydrogeological and hydrogeochemical data indicate the presence of remarkably uniform and predictable geology, physical hydrogeologic and geochemical properties over well separation distances exceeding 1 km. The current data set including 2-D seismic reflection surveys, field and lab hydraulic testing, lab petrophysical and

  9. Waste repository planned for Bruce Site

    International Nuclear Information System (INIS)

    King, F.

    2004-01-01

    Ontario Power Generation (OPG) and Kincardine, the municipality nearest the Bruce site, have agreed in principal to the construction of a deep geologic repository for low and medium level radioactive waste on the site. The two parties signed the 'Kincardine Hosting Agreement' on October 13, 2004 to proceed with planning, seek regulatory approval and further public consultation of the proposed project. A construction Licence is not expected before 2013. (author)

  10. Corrosion-product inventory: the Bruce-B secondary system

    International Nuclear Information System (INIS)

    Sawicki, J.A.; Price, J.; Brett, M.E.

    1995-01-01

    Corrosion inspection and corrosion-product characterization in water and steam systems are important for component and systems maintenance in nuclear power stations. Corrosion products are produced, released and redeposited at various sites in the secondary system. Depending on the alloys used in the condenser and feedwater heaters, particulate iron oxides and hydroxides can account for about 95-99% of the total corrosion-product transport. Where brass or cupro-nickel alloys are present, copper and zinc contribute significantly to the total transport and deposition. Particulates are transported by the feedwater to the steam generators, where they accumulate and can cause a variety of problems, such as loss of heat transfer capability through deposition on boiler tubes, blockage of flow through boiler-tube support plates and accelerated corrosion in crevices, either in deep sludge piles or at blocked tube supports. The influx of oxidized corrosion products may have a particularly adverse effect on the redox environment of steam generator tubing, thereby increasing the probability of localized corrosion and other degradation mechanisms. In this paper, there is a description of a survey of general corrosion deposits in Bruce-B, Units 5-8, which helps to identify the origin, evolution and inventory of corrosion products along the secondary system of Candu reactors

  11. Status of the reliability centered maintenance program at Ontario Hydro's Bruce 'A' Nuclear Division

    International Nuclear Information System (INIS)

    Khan, I.

    1995-01-01

    Bruce A started a preventive maintenance (PM) quality improvement program in August of 1991. This initiative was taken to address the concerns expressed by the AECB and the Peer Audits finding. The concerns were on the quality of the Bruce A PM Program and its execution in the field. Reliability Centered Maintenance (RCM) analysis was selected as the PM program quality improvement and optimization technique. Therefore, RCM became a key component of Bruce A's Integrated PM program and maintenance strategy. As a result of RCM implementation, and improvements in the work planning and scheduling process, Bruce A is seeing downward trends in the corrective maintenance work load, maintenance preventable forced outages, overdue/missed PM tasks and corrective maintenance backlog. Control Room Operators have reported observing an improvement in systems and equipment response to transients. Other benefits include a documented, controlled and traceable PM program. In addition, the team approach required by RCM has started to improve staff confidence in the PM program which, in turn, is improving the compliance with the PM program. (author)

  12. Evolution of CANDU reactor design

    International Nuclear Information System (INIS)

    Pon, G.A.

    1978-08-01

    The CANDU (CANada Deuterium Uranium) design had its begin-ings in the early 1950's with the preliminary engineering studies that led to the 20 MW(e) NPD (Nuclear Power Demonstration) and the 200 MW(e) Douglas Point station . The next decade saw the first operation of both these stations and the commitment of the 2000 MW(e) Pickering and 3000 MW(e) Bruce plants. The present decade has witnessed the excellent performance of Pickering and Bruce and commitments to construct Gentilly-2, Cordoba, Pt. Lepreau, Wolsung, Pickering B, Bruce B and Darlington. In most cases, successive CANDU designs have meant an increase in plant output. Evolutionary developments have been made to fit the requirements of higher ratings and sizes, new regulations, better reliability and maintainability and lower costs. These changes, which are described system by system, have been introduced in the course of engineering parallel reactor projects with overlapping construction schedules -circumstances which ensure close contact with the practical realities of economics, manufacturing functions, construction activities and performance in commissioning. Features for one project furnished alternative concepts for others still on the drawing board and the experience gained in the first application yielded a sound basis for its re-use in succeeding projects. Thus the experiences gained in NPD, Douglas Point, Gentilly-1 and KANUPP have contributed to Pickering and Bruce, which in turn have contributed to the design of Gentilly-2. (author)

  13. Fire fighting capability assessment program Bruce B NGS

    International Nuclear Information System (INIS)

    1995-05-01

    This is a report on the completion of work relating to the assessment of the capability of Bruce B NGS to cope with a large fire incident. This included an evaluation of an exercise scenario that would simulate a large fire incident and of their fire plans and procedures. Finally the execution of fire plans by Bruce B NGS, as demonstrated by their application of human and material resources during a simulated large fire, was observed. The fire fighting equipment and the personal protective clothing and associated equipment that was in use was all of good quality and in good condition. There had also been notable improvement in communications equipment. Similarly, the human resources that had been assigned to fire fighting and rescue crews and that were available were more than adequate. Use of a logical incident command system, and the adoption of proper policy and procedures for radio communications were equally significant improvements. Practice should correct the breakdowns that occurred in these areas during the exercise. As well, there remains a need for the development of policy on fire fighting and rescue operations with more depth and clarity. In summary, the key point to be recognized is the degree of improvement that has been realized since the previous evaluation in 1990. Clearly the Emergency Response Teams organization of Bruce B NGS is evolving into an effective fire fighting force. Providing that the deficiencies identified in this report are addressed satisfactorily, Fire Cross is confident that the organization will have the capability to provide rescue and fire fighting services that will satisfy the need. 2 figs

  14. Projecting Dynastic Majesty: State Ceremony in the Reign of Robert Bruce

    Directory of Open Access Journals (Sweden)

    Lucinda Dean

    2015-07-01

    Full Text Available Following the murder of his rival John Comyn on 10 February at Greyfriars in Dumfries, and the crisis this act incited, Robert the Bruce’s inaugural ceremony took place at Scone in late March 1306. Much about this ceremony is speculative; however, subsequent retrospective legitimisation of the Bruce claims to the royal succession would suggest that all possible means by which Robert’s inauguration could emulate his Canmore predecessors and outline his right to rule on a level playing field with his contemporaries were amplified, particularly where they served the common purpose of legitimising Robert’s highly questioned hold on power. Fourteenth-century Scottish history is inextricably entwined in the Wars of Independence, civil strife and an accelerated struggle for autonomous rule and independence. The historiography of this period is unsurprisingly heavily dominated by such themes and, while this has been offset by works exploring subjects such as the tomb of Bruce and the piety of the Bruce dynasty, the ceremonial history of this era remains firmly in the shadows. This paper will address three key ceremonies through which a king would, traditionally, make powerful statements of royal authority: the inauguration or coronation of Bruce; the marriage of his infant son to the English princess Joan of the Tower in 1328, and his extravagant funeral ceremony in 1329. By focusing thus this paper hopes to shed new light on the ‘dark and drublie days’ of fourteenth-century Scotland and reveal that glory, dynastic majesty and pleasure were as central to the Scottish monarchy in this era as war and political turbulence.

  15. Reactor noise analysis applications in NPP I and C systems

    Energy Technology Data Exchange (ETDEWEB)

    Gloeckler, O. [International Atomic Energy Agency, Wagramer Strosse 5, A-1400 Vienna, Austria Ontario Power Generation, 230 Westney Road South, Ajax, Ont. L1S 7R3 (Canada)

    2006-07-01

    Reactor noise analysis techniques are used in many NPPs on a routine basis as 'inspection tools' to get information on the dynamics of reactor processes and their instrumentation in a passive, non-intrusive way. The paper discusses some of the tasks and requirements an NPP has to take to implement and to use the full advantages of reactor noise analysis techniques. Typical signal noise analysis applications developed for the monitoring of the reactor shutdown system and control system instrumentation of the Candu units of Ontario Power Generation and Bruce Power are also presented. (authors)

  16. Steam generator replacement at Bruce A: approach, results, and lessons learned

    International Nuclear Information System (INIS)

    Tomkiewicz, W.; Savage, B.; Smith, J.

    2008-01-01

    Steam Generator Replacement is now complete in Bruce A Units 1 and 2. In each reactor, eight steam generators were replaced; these were the first CANDU steam generator replacements performed anywhere in the world. The plans for replacement were developed in 2004 and 2005, and were summarized in an earlier paper for the CNS Conference held in November, 2006. The present paper briefly summarizes the methodologies and special processes used such as metrology, cutting and welding and heavy lifting. The paper provides an update since the earlier report and focuses on the project achievements to date, such as: - A combination of engineered methodology, laser metrology and precise remote machining led to accurate first time fit-ups of each new replacement steam generator and steam drums - Lessons learned in the first unit led to schedule improvements in the second unit - Dose received was lowest recorded for any steam generator replacement project. The experience gained and lessons learned from Units 1 and 2 will be valuable in planning and executing future replacement steam generator projects. A video was presented

  17. Fuel defect detection, localization and removal in Bruce Power units 3 through 8

    International Nuclear Information System (INIS)

    Stone, R.; Armstrong, J.; Iglesias, F.; Oduntan, R.; Lewis, B.

    2005-01-01

    Fuel element defects are occurring in Bruce 'A' and Bruce 'B' Units. A root-cause investigation is ongoing, however, a solution is not yet in-hand. Fuel defect management efforts have been undertaken, therefore, in the interim. Fuel defect management tools are in-place for all Bruce Units. These tools can be categorized as analysis-based or operations-based. Analysis-based tools include computer codes used primarily for fuel defect characterization, while operations-based tools include Unit-specific delayed-neutron ('DN') monitoring systems and gaseous fission product ('GFP') monitoring systems. Operations-based tools are used for fuel defect detection, localization and removal activities. Fuel and Physics staff use defect detection, localization and removal methodologies and guidelines to disposition fuel defects. Methodologies are 'standardized' or 'routine' procedures for implementing analysis-based and operations-based tools to disposition fuel defects during Unit start-up operation and during operation at high steady-state power levels. Guidelines at present serve to supplement fuel defect management methodologies during Unit power raise. (author)

  18. AECB staff annual report of Bruce Heavy Water Plant operation for the year 1991

    International Nuclear Information System (INIS)

    1992-11-01

    Bruce Heavy Water Plant operation was acceptably safe in 1991. There were no breaches of any of the regulations issued under the authority of the Atomic Energy Control Act. There was one violation of the operating licence. For one hour on October 30, 1991, water leaving the plant contained more hydrogen sulphide than Ontario regulations allow. There was no threat to public health or safety or harm to the environment as a result of this violation. One worker was overcome by hydrogen sulphide. The worker did not lose consciousness, but had the symptoms of H 2 S poisoning. Ontario Hydro took actions to increase awareness of the Operating Policy and Principles at Bruce Heavy Water Plant during 1991. All personnel attended a training course, and Ontario Hydro is reviewing all Bruce Heavy Water Plant documentation to ensure it is consistent with the Operating Policies and Principles. Ontario Hydro met 13 of 15 safety-related system availability targets. The AECB is satisfied appropriate action is being taken to improve the performance of the other two systems. Ontario Hydro continued to put heavy emphasis on safety training; however, they did not meet some of their other training targets. Ontario Hydro completed all of the planned emergency exercises at Bruce Heavy Water Plant in 1991. (Author)

  19. AECB staff review of Bruce NGS 'A' operation for the year 1989

    International Nuclear Information System (INIS)

    1990-06-01

    The operation of the Bruce Nuclear Generating Station 'B' is monitored and licensing requirements are enforced by the Atomic Energy Control Board (AECB). This report records the conclusions of the AECB staff assessment of Bruce NGS 'A' during 1989 and the early part of 1990. Overall operation of the station met acceptable safety standards. Despite numerous problems and technical difficulties encountered, station management and supervisory personnel acted with due caution and made decisions in the interests of safety. There was evidence of improvement in a number of key areas, supported by pertinent indicators in the objective measures table. The extensive inspection and maintenance programs carried out during the year revealed the extent of component deterioration due to aging to be larger than expected. Hydrogen embrittlement of pressure tubes, erosion/corrosion of steam and feed water valves, heat exchanger tubes and piping, fouling of boilers and heat exchangers, and environmental damage of electrical equipment are examples. Continued aging of plant equipment and its potential for reducing the margins for safe operation must be taken into account by Ontario Hydro in establishing priorities and target dates for completion of actions to resolve identified problems at Bruce NGS 'A'. (2 tabs.)

  20. Primary separator replacement for Bruce Unit 8 steam generators

    International Nuclear Information System (INIS)

    Roy, S.B.; Mewdell, C.G.; Schneider, W.G.

    2000-01-01

    During a scheduled maintenance outage of Bruce Unit 8 in 1998, it was discovered that the majority of the original primary steam separators were damaged in two steam generators. The Bruce B steam generators are equipped with GXP type primary cyclone separators of B and W supply. There were localized perforations in the upper part of the separators and large areas of generalized wall thinning. The degradation was indicative of a flow related erosion corrosion mechanism. Although the unit- restart was justified, it was obvious that corrective actions would be necessary because of the number of separators affected and the extent of the degradation. Repair was not considered to be a practical option and it was decided to replace the separators, as required, in Unit 8 steam generators during an advanced scheduled outage. GXP separators were selected for replacement to minimize the impact on steam generator operating characteristics and analysis. The material of construction was upgraded from the original carbon steel to stainless steel to maximize the assurance of full life. The replacement of the separators was a first of a kind operation not only for Ontario Power Generation and B and W but also for all CANDU plants. The paper describes the degradations observed and the assessments, the operating experience, manufacture and installation of the replacement separators. During routine inspection in 1998, many of the primary steam separators in two of steam generators at Bruce Nuclear Division B Unit 8 were observed to have through wall perforations. This paper describes assessment of this condition. It also discusses the manufacture and testing of replacement primary steam separators and the development and execution of the replacement separator installation program. (author)

  1. Life extension of CANDU reactor cores

    International Nuclear Information System (INIS)

    Millard, J.; Kerker, J.; Albert, M.

    2011-01-01

    Candu Energy (formerly AECL), in partnership with station operators, has developed a robust methodology for demonstrating the fitness of reactor core structures, and associated reactivity control devices, as an essential element in conducting a station life extension project. The ageing of reactors is affected by ageing mechanisms impacted by operational history and design related factors such as materials, chemistries and stress distributions. The methodology of this life extension work is based on the IAEA TECDOC 1197; which documents practices for ageing management in CANDU reactors. This paper uses the work in Bruce Units 1 and 2, conducted from 2007 through to 2011, to explain the methodology. The work started with analysis of historical operational conditions and identification of the forms of degradation that could have occurred. The assessment and related inspections considered the safety and pressure boundary significance of each item, as well as its failure modes and margins. It then moved through both general and local inspection, focused mainly inside the calandria vessel once the calandria tubes were removed. The inspection found the bulk of the hardware to be in good condition, with a small number of remediation opportunities. In the course of that remediation some foreign material was sampled and removed. The minor remediation was successful and the work was completed through formal documentation of the fitness for extended life. It has been demonstrated through these analyses and visual inspections that the reactor structures and components inspected are free of indications and active degradation mechanisms that would prevent the safe and reliable operation of Bruce A Units 1 and 2 through its next 25 years of life. (author)

  2. Mitigation of organically bound sulphate from water treatment plants at Bruce NGS and impact on steam generator secondary side chemistry control

    Energy Technology Data Exchange (ETDEWEB)

    Nashiem, R.; Davloor, R.; Harper, B.; Smith, K. [Bruce Power, Tiverton, Ontario (Canada); Gauthier, C. [CTGIX Services Inc., Burlington, Ontario (Canada); Schexnailder, S. [GE Water and Process Technologies, Dallas, Texas (United States)

    2010-07-01

    Bruce Power is the source of more than 20 per cent of Ontario's electricity and currently operates six reactor units at the Bruce Nuclear Generating Station A (two units) and B (four units) stations located on Lake Huron. This paper discusses the challenges faced and operating experience (OPEX) gained in meeting WANO 1.0 chemistry performance objectives for steam generator secondary side chemistry control, particularly with control of steam generator sulphates. A detailed sampling and analysis program conducted as part of this study concluded that a major contributor to steam generator (SG) elevated sulphates is Organically Bound Sulphate (OBS) in Water Treatment Plants (WTP) effluent. The Bruce A and B WTPs consist of clarification with downstream sand and carbon filtration for Lake Water pre-treatment, which are followed by conventional Ion Exchange (IX) demineralization. Samples taken from various locations in the process stream were analyzed for a variety of parameters including both organic bound and inorganic forms of sulphate. The results are inconclusive with respect to finding the definitive source of OBS. This is primarily due to the condition that the OBS in the samples, which are in relatively low levels, are masked during chemical analysis by the considerably higher inorganic sulphate background. Additionally, it was also determined that on-line Total Organic Carbon (TOC) levels at different WTP locations did not always correlate well with OBS levels in the effluent, such that TOC could not be effectively used as a control parameter to improve OBS performance of the WTP operation. Improvement efforts at both plants focused on a number of areas including optimization of clarifier operation, replacement of IX resins, addition of downstream mobile polishing trailers, testing of new resins and adsorbents, pilot-scale testing with a Reverse Osmosis (RO) rig, review of resin regeneration and backwashing practices, and operating procedure improvements

  3. Mitigation of organically bound sulphate from water treatment plants at Bruce NGS and impact on steam generator secondary side chemistry control

    International Nuclear Information System (INIS)

    Nashiem, R.; Davloor, R.; Harper, B.; Smith, K.; Gauthier, C.; Schexnailder, S.

    2010-01-01

    Bruce Power is the source of more than 20 per cent of Ontario's electricity and currently operates six reactor units at the Bruce Nuclear Generating Station A (two units) and B (four units) stations located on Lake Huron. This paper discusses the challenges faced and operating experience (OPEX) gained in meeting WANO 1.0 chemistry performance objectives for steam generator secondary side chemistry control, particularly with control of steam generator sulphates. A detailed sampling and analysis program conducted as part of this study concluded that a major contributor to steam generator (SG) elevated sulphates is Organically Bound Sulphate (OBS) in Water Treatment Plants (WTP) effluent. The Bruce A and B WTPs consist of clarification with downstream sand and carbon filtration for Lake Water pre-treatment, which are followed by conventional Ion Exchange (IX) demineralization. Samples taken from various locations in the process stream were analyzed for a variety of parameters including both organic bound and inorganic forms of sulphate. The results are inconclusive with respect to finding the definitive source of OBS. This is primarily due to the condition that the OBS in the samples, which are in relatively low levels, are masked during chemical analysis by the considerably higher inorganic sulphate background. Additionally, it was also determined that on-line Total Organic Carbon (TOC) levels at different WTP locations did not always correlate well with OBS levels in the effluent, such that TOC could not be effectively used as a control parameter to improve OBS performance of the WTP operation. Improvement efforts at both plants focused on a number of areas including optimization of clarifier operation, replacement of IX resins, addition of downstream mobile polishing trailers, testing of new resins and adsorbents, pilot-scale testing with a Reverse Osmosis (RO) rig, review of resin regeneration and backwashing practices, and operating procedure improvements

  4. Fuelling with flow at Bruce A

    Energy Technology Data Exchange (ETDEWEB)

    Gray, M G [Canadian General Electric Co. Ltd., Peterborough, ON (Canada)

    1997-12-31

    Fuelling with flow is the solution chosen by Bruce A to overcome the potential power pulse caused by a major inlet header failure. Fuelling with flow solves the problem by rearranging the core to place new fuel at the channel inlet and irradiated fuel at the channel outlet. The change has a significant impact on the Bruce A fuel handling system which was designed primarily to do on power fuelling in the against flow direction. Mechanical changes to the fuelling machine include a modification to the existing ram head and the replacement of standard fuel carriers with new fuelling with flow fuel carriers having the capability of opening the channel latch. Changes to the control system are more involved. A new set of operational sequences are required for both the upstream and downstream fuelling machines to achieve the fuel change. Steps based on sensitive ram push are added to reduce the risk of failing to close the latch at the correct position to properly support the fuel string. Changes are also required to the protective interlocks to allow fuelling with flow and reduce risk. A new fuel string supporting shield plug was designed and tested to reduce the risk of endplate cracking that could occur on the irradiated bundle that would have been supported directly by the channel latch. Some operational changes have been incorporated to accommodate this new shield plug. Considerable testing has been carried out on all aspects of fuel handling where fuelling with flow differs from the reference fuelling against flow. (author). 3 figs.

  5. Environmental health scoping study at Bruce Heavy Water Plant

    International Nuclear Information System (INIS)

    Prior, M.; Mostrom, M.; Coppock, R.; Florence, Z.

    1995-10-01

    There are concerns that hydrogen sulfide released from the Heavy Water Plant near Kincardine, Ontario may be the cause of the mortalities and morbidities observed in a nearby flock of sheep. The Philosopher's Wool sheep farm is about four kilometres south-southeast of the Bruce Heavy Water Plant. Ontario Hydro, the owner and operator of the Bruce Heavy Water Plant, claims that hydrogen sulphide emissions from the Bruce Heavy Water Plant are within regulatory limits and well below levels that cause harm. Accordingly, the Atomic Energy Control Board commissioned the Alberta Environmental Centre, Alberta Department of Environmental Protection, to develop a scoping study for this environmental health issue. The first objective was to describe a field investigation model to define clearly the environmental health and operation of the sheep farm. The second objective was to describe possible exposure patterns and develop a holistic environmental pathway model. If appropriate, the third study objective was to describe animal models of the actual situation to elucidate specific aspects of the environmental health concerns. It was not the objective of this report to provide a definitive answer to the present environmental health issue. Ontario Hydro provided data to the Alberta Environmental Centre, as di the sheep farmer, the attending veterinarian, the University of Guelph study team, and the Atomic Energy Control Board. A six-tiered strategy of sequential evaluations of the ovine health problem is based on the multiple-response paradigm. It assumes the observed ovine health results are the result of multiple effector events. Each tier constitutes a separate, but inter-related, study. Sequential evaluation and feedback of each tier allow sound scientific judgements and efficient use of resources. (author). 59 refs., 11 tabs., 22 figs

  6. Measurements of Sheath Temperature Profiles in Bruce LVRF Bundles Under Post-Dryout Heat Transfer Conditions in Freon

    International Nuclear Information System (INIS)

    Guo, Y.; Bullock, D.E.; Pioro, I.L.; Martin, J.

    2006-01-01

    An experimental program has been completed to study the behaviour of sheath wall temperatures in the Bruce Power Station Low Void Reactivity Fuel (shortened hereafter to Bruce LVRF) bundles under post-dryout (PDO) heat-transfer conditions. The experiment was conducted with an electrically heated simulator of a string of nine Bruce LVRF bundles, installed in the MR-3 Freon heat transfer loop at the Chalk River Laboratories (CRL), Atomic Energy of Canada Limited (AECL). The loop used Freon R-134a as a coolant to simulate typical flow conditions in CANDU R nuclear power stations. The simulator had an axially uniform heat flux profile. Two radial heat flux profiles were tested: a fresh Bruce LVRF profile and a fresh natural uranium (NU) profile. For a given set of flow conditions, the channel power was set above the critical power to achieve dryout, while heater-element wall temperatures were recorded at various overpower levels using sliding thermocouples. The maximum experimental overpower achieved was 64%. For the conditions tested, the results showed that initial dryout occurred at an inner-ring element at low flows and an outer-ring element facing internal subchannels at high flows. Dry-patches (regions of dryout) spread with increasing channel power; maximum wall temperatures were observed at the downstream end of the simulator, and immediately upstream of the mid-bundle spacer plane. In general, maximum wall temperatures were observed at the outer-ring elements facing the internal subchannels. The maximum water-equivalent temperature obtained in the test, at an overpower level of 64%, was significantly below the acceptable maximum temperature, indicating that the integrity of the Bruce LVRF will be maintained at PDO conditions. Therefore, the Bruce LVRF exhibits good PDO heat transfer performance. (authors)

  7. An intelligent safety system concept for future CANDU reactors

    International Nuclear Information System (INIS)

    Hinds, H.W.

    1980-01-01

    A review of the current Regional Over-power Trip (ROPT) system employed on the Bruce NGS-A reactors confirmed the belief that future reactors should have an improved ROPT system. We are developing such an 'intelligent' safety system. It uses more of the available information on reactor status and employs modern computer technology. Fast triplicated safety computers compute maps of fuel channel power, based on readings from prompt-responding flux detectors. The coefficients for this calculation are downloaded periodically from a fourth supervisor computer. These coefficients are based on a detailed 3-D flux shape derived from physics data and other plant information. A demonstration of one of three safety channels of such a system is planned. (auth)

  8. Burnup calculation of a CANDU6 reactor using the Serpent and MCNP6 codes

    Energy Technology Data Exchange (ETDEWEB)

    Hussein, M.S.; Bonin, H.W., E-mail: mohamed.hussein@rmc.ca, E-mail: bonin-h@rmc.ca [Royal Military College of Canada, Dept. of Chemistry and Chemical Engineering, Kingston, ON (Canada); Lewis, B.J., E-mail: Brent.Lewis@uoit.ca [Univ. of Ontario Inst. of Tech., Faculty of Energy Systems and Nuclear Science, Oshawa, ON (Canada)

    2014-07-01

    A study of fuel burnup for the CANDU6 reactor is carried out to validate the most recent versions of the probabilistic transport code (MCNP6) and the continuous energy burnup calculation code (Serpent). These two codes allow for 3-D geometry calculation accounting for a detailed analysis without unit-cell homogenization. On the other hand, the WIMS-AECL computer program is used to model neutron transport in nuclear-reactor lattices for design, safety analysis, and operation. It works with two-dimensional regions and can perform collision probability calculations for a periodic structure of the lattice cell. In the present work, the multiplication factor, the total flux and fuel burnup could be calculated for a CANDU6 nuclear reactor based on the GENTILLY-2 core design. The MCNP6 and Serpent codes provide a calculation of the track length estimated flux per neutron source. This estimated flux is then scaled with normalization to the reactor power in order to provide a flux in unit of n/cm{sup 2}s. Good agreement is observed between the actual total flux calculated by MCNP6, Serpent and WIMS-AECL. The effective multiplication factors of the whole core CANDU6 reactor are further calculated as a function of burnup and further compared to those calculated by WIMS-AECL where excellent agreement is also obtained. (author)

  9. Burnup calculation of a CANDU6 reactor using the Serpent and MCNP6 codes

    International Nuclear Information System (INIS)

    Hussein, M.S.; Bonin, H.W.; Lewis, B.J.

    2014-01-01

    A study of fuel burnup for the CANDU6 reactor is carried out to validate the most recent versions of the probabilistic transport code (MCNP6) and the continuous energy burnup calculation code (Serpent). These two codes allow for 3-D geometry calculation accounting for a detailed analysis without unit-cell homogenization. On the other hand, the WIMS-AECL computer program is used to model neutron transport in nuclear-reactor lattices for design, safety analysis, and operation. It works with two-dimensional regions and can perform collision probability calculations for a periodic structure of the lattice cell. In the present work, the multiplication factor, the total flux and fuel burnup could be calculated for a CANDU6 nuclear reactor based on the GENTILLY-2 core design. The MCNP6 and Serpent codes provide a calculation of the track length estimated flux per neutron source. This estimated flux is then scaled with normalization to the reactor power in order to provide a flux in unit of n/cm 2 s. Good agreement is observed between the actual total flux calculated by MCNP6, Serpent and WIMS-AECL. The effective multiplication factors of the whole core CANDU6 reactor are further calculated as a function of burnup and further compared to those calculated by WIMS-AECL where excellent agreement is also obtained. (author)

  10. Integrated inspection programs at Bruce Heavy Water Plant

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K C [Ontario Hydro, Tiverton, ON (Canada)

    1993-12-31

    Quality pressure boundary maintenance and an excellent loss prevention record at Bruce Heavy Water Plant are the results of the Material and Inspection Unit`s five inspection programs. Experienced inspectors are responsible for the integrity of the pressure boundary in their own operating area. Inspectors are part of the Technical Section, and along with unit engineering staff, they provide technical input before, during, and after the job. How these programs are completed, and the results achieved, are discussed. 5 figs., 1 appendix.

  11. Integrated inspection programs at Bruce Heavy Water Plant

    International Nuclear Information System (INIS)

    Brown, K.C.

    1992-01-01

    Quality pressure boundary maintenance and an excellent loss prevention record at Bruce Heavy Water Plant are the results of the Material and Inspection Unit's five inspection programs. Experienced inspectors are responsible for the integrity of the pressure boundary in their own operating area. Inspectors are part of the Technical Section, and along with unit engineering staff, they provide technical input before, during, and after the job. How these programs are completed, and the results achieved, are discussed. 5 figs., 1 appendix

  12. Proceedings of the 6. National Meeting of Reactor Physics and Thermohydraulic

    International Nuclear Information System (INIS)

    1986-01-01

    The proceedings of the 6. National Meeting of Reactor Physics and Thermohydraulic - 6. ENFIR - allow to evaluate the present status of development in reactor physics and thermohydraulic fields. The mathematical models and methods for calculating neutronic of nuclear reactors, safety reactor analysis, measuring methods of neutronic parameters, computerized simulation of accidents, transients and thermohydraulic analysis are presented. (M.C.K.) [pt

  13. Enhanced CANDU 6 (EC6): a proven mid-sized reactor with fuel cycle capability

    International Nuclear Information System (INIS)

    Hopwood, J.; Soulard, M.; Hastings, I.J.

    2011-01-01

    Atomic Energy of Canada (AECL) is finalizing development of the Enhanced CANDU 6 (EC6), which incorporates the CANDU 6's well-proven features, and adds enhancements that make the reactor even more safe and easier to operate. The EC6 is the only mid-sized reactor (700 MWe class) with a proven pedigree that meets modern reactor expectations and regulatory standards. It is sized for smaller grids and also has outstanding fuel-cycle capability. Changes are incremental and consistent with the CANDU 6 project approach. The EC6 utilizes modern computers and a distributed control system housed in an advanced control room which, along with automated testing and on-line diagnostics, make the plant easier and safer to operate, with minimal operator intervention. Containment and seismic capability are upgraded to meet modern standards. The first deployment of the EC6 is anticipated in Canada; international markets are also being pursued. AECL is performing a comprehensive review of the EC6 design in the wake of the Fukushima accident, will review lessons learned, and incorporate any necessary improvements into new build design. (author)

  14. Enhanced CANDU 6 (EC6): a proven mid-sized reactor with fuel cycle capability

    International Nuclear Information System (INIS)

    Hopwood, J.; Soulard, M.; Hastings, I.J.

    2011-01-01

    Atomic Energy of Canada (AECL) is finalizing development of the Enhanced CANDU 6 (EC6), which incorporates the CANDU 6's well-proven features, and enhancements that make the reactor even more safe and easier to operate. The EC6 is the only mid-sized reactor (700 MWe class) with a proven pedigree that meets modern reactor expectations and regulatory standards. It is sized for smaller grids and also has outstanding fuel-cycle capability. Changes are incremental and consistent with the CANDU 6 project approach. The EC6 utilizes modern computers and a distributed control system housed in an advanced control room which, along with automated testing and on-line diagnostics, make the plant easier and safer to operate, with minimal operator intervention. Containment and seismic capability are upgraded to meet modern standards. The first deployment of the EC6 is anticipated in Canada; international markets are also being pursued. AECL is performing a comprehensive review of the EC6 design in the wake of the Fukushima accident, will review lessons learned, and incorporate any necessary improvements into new build design. (author)

  15. Design of the MiniSLAR system for Bruce A

    International Nuclear Information System (INIS)

    Gray, M.G.

    1995-01-01

    Cancellation of Bruce A Retube created the need to perform SLAR on Unit 1. The existing SLAR system cannot reach Unit 1 and alternative systems had limitations. The concept and design of MiniSLAR were driven by the availability of existing components made for Retube. The MiniSLAR concept was developed by a team with members representing operators, technicians, and designers from various departments within Ontario Hydro and GE Canada. Overall project leadership was provided by Bruce A Projects and Modifications Department with assistance from Ontario Hydro Nuclear Technology Services. The responsibility for detailed design was assigned by Ontario Hydro to GE Canada. The detailed design proceeded with continual input and review by the team. The MiniSLAR delivery machine consists of a closure removal ram, a shield plug removal ram and a SLAR tool delivery ram attached to the sliding plate of a horizontal indexing mechanism. The moving plate is constrained by guide rails to a fixed plate and seals against it with o-rings. A snout and clamping mechanism mounts on the front of the fixed plate. The machine mounts atop a work table which provides the various motions required for endfitting engagement. Some operations are performed manually while others are remote and automatic. (author)

  16. Methyl iodide trapping efficiency of aged charcoal samples from Bruce-A emergency filtered air discharge systems

    International Nuclear Information System (INIS)

    Wren, J.C.; Moore, C.J.; Rasmussenn, M.T.; Weaver, K.R.

    1999-01-01

    Charcoal filters are installed in the emergency filtered air discharge system (EFADS) of multiunit stations to control the release of airborne radioiodine in the event of a reactor accident. These filters use highly activated charcoal impregnated with triethylenediamine (TEDA). The TEDA-impregnated charcoal is highly efficient in removing radioiodine from flowing airstreams. The iodine-removal efficiency of the charcoal is presumed to deteriorate slowly with age, but current knowledge of this effect is insufficient to predict with confidence the performance of aged charcoal following an accident. Experiments were performed to determine the methyl iodide removal efficiency of aged charcoal samples taken from the EFADS of Ontario Hydro's Bruce-A nuclear generating station. The charcoal had been in service for ∼4 yr. The adsorption rate constant and capacity were measured under post-loss-of-coolant accident conditions to determine the efficiency of the aged charcoal. The adsorption rate constants of the aged charcoal samples were observed to be extremely high, yielding a decontamination factor (DF) for a 20-cm-deep bed of the aged charcoal >1 X 10 15 . The results show that essentially no CH 3 I would escape from a 20-cm-deep bed of the aged charcoal and that the requirement for a DF of 1000 for organic iodides in the EFADS filters would be exceeded by a tremendous margin. With such high DFs, the release of iodine from a 20-cm-deep bed would be virtually impossible to detect. The adsorption capacities observed for the aged charcoal samples approach the theoretical chemisorption capacity of 5 wt% TEDA charcoal, indicating that aging in the EFADS for 4 yr has had a negligible impact on the adsorption capacity. The results indicate that the short- and long-term performances of the aged charcoal in the EFADS of Bruce-A following an accident would still far exceed performance requirements. (author)

  17. Characterisation of reactor control rod drives. Specification 1-6. Reaktorstellstabantriebe. Typenblaetter 1-6

    Energy Technology Data Exchange (ETDEWEB)

    1975-03-01

    The committee 'Kernreaktorregelung' of VDI/VDE-Gesellschaft Mess- und Regelungstechnik has developed 6 specifications (Typenblaetter) of reactor control rod drives. The specifications are aimed at giving engineers in reactor control systems an outline concerning the function as well as some construction characteristics. (orig./LN).

  18. Enhanced CANDU 6 Reactor

    International Nuclear Information System (INIS)

    Azeez, S.; Alizadeh, A.; Girouard, P.

    2005-01-01

    Full text: The CANDU 6 power reactor is visionary in its approach, remarkable for its on-power refuelling capability and proven over years of safe, economical and reliable power production. Developed by Atomic Energy of Canada Ltd, the CANDU 6 design offers excellent performance utilizing state-of-the-art technology. The first CANDU 6 plants went into service in the early 1980's as leading edge technology and the design has been continuously advanced to maintain superior performance with an outstanding safety record. The first CANDU 6 plants- Gentilly 2 and Point Lepreau in Canada, Embalse in Argentina and Wolsong- Unit 1 in Korea have been in service for more than 21 years and are still producing electricity at peak performance and to the end of 2004, their average lifetime Capacity Factor was 83.2%. The newer CANDU 6 units in Romania (Cernavoda 1), Korea (Wolsong-Units 2, 3 and 4) and Qinshan (Phase III- Units 1 and 2) have also been performing at outstanding levels. The average lifetime Capacity Factor of the 10 CANDU 6 operating units around the world has been 87% to the end of 2004. Building on these successes, AECL is committed to the further development of this highly successful design, now focussing on meeting customer's needs for reduced costs, further improvements to plant operation and performance, enhanced safety and incorporating up-to-date technology as warranted. This has resulted in AECL embarking on improving the CANDU 6 design through an upgraded product termed as the 'Enhanced CANDU 6' (EC6)- which incorporates several attractive but proven features that will make the CANDU 6 reactor even more economical, safer and easier to operate. Some of the key features that will be incorporated in the EC6 include increasing the plant's power output, shortening the overall project schedule, decreasing the capital cost, dealing with obsolescence issues, optimizing maintenance outages and incorporating lessons learnt through feedback obtained from the

  19. An appreciation of Bruce and Young's (1986) serial stage model of face naming after 25 years.

    Science.gov (United States)

    Hanley, J Richard

    2011-11-01

    The current status of Bruce and Young's (1986) serial model of face naming is discussed 25 years after its original publication. In the first part of the paper, evidence for and against the serial model is reviewed. It is argued that there is no compelling reason why we should abandon Bruce and Young's claim that recall of a name is contingent upon prior retrieval of semantic information about the person. The current status of the claim that people's names are more difficult to recall than the names of objects is then evaluated. Finally, an account of the anatomical location in the brain of Bruce and Young's three processing stages (face familiarity, retrieval of semantic information, retrieval of names) is suggested. In particular, there is evidence that biographical knowledge about familiar people is stored in the right anterior temporal lobes (ATL) and that the left temporal pole (TP) is heavily involved in retrieval of the names of familiar people. The issue of whether these brain areas play a similar role in object processing is also discussed. ©2011 The British Psychological Society.

  20. The status of improved pressurized heavy water reactor development - A new option for PHWR -

    International Nuclear Information System (INIS)

    Park, Tae Keun; Yeo, Ji Won

    1996-03-01

    Currently, the 900 MWe class Improved Pressurized Heavy Water Reactor (PHWR), which is a type of CANDU reactor based on the systems and components of operating CANDU plants, is under development. The improved PHWR has a 480 fuel channel calandria, uses 37 element natural uranium fuel bundles and has a single unit containment. Adaptation of a steel-lined containment structure and improved containment isolation systems permit a reduced exclusion area boundary (EAB) compared to the existing larger capacity CANDU reactors (Darlington, Bruce B). The improved PHWR buildings are arranged to achieve minimum spacing between reactor units. Plant safety and economy are increased through various design changes based on the operating experience of existing CANDU plants. 4 refs. (Author)

  1. Thermal and fast reactor benchmark testing of ENDF/B-6.4

    International Nuclear Information System (INIS)

    Liu Guisheng

    1999-01-01

    The benchmark testing for B-6.4 was done with the same benchmark experiments and calculating method as for B-6.2. The effective multiplication factors k eff , central reaction rate ratios of fast assemblies and lattice cell reaction rate ratios of thermal lattice cell assemblies were calculated and compared with testing results of B-6.2 and CENDL-2. It is obvious that 238 U data files are most important for the calculations of large fast reactors and lattice thermal reactors. However, 238 U data in the new version of ENDF/B-6 have not been renewed. Only data of 235 U, 27 Al, 14 N and 2 D have been renewed in ENDF/B-6.4. Therefor, it will be shown that the thermal reactor benchmark testing results are remarkably improved and the fast reactor benchmark testing results are not improved

  2. Future plans for performance analysis and maintenance/inspection optimization of shutoff rods based on the case study of Bruce Power Unit-3 Shutoff Rod 5 inspection

    International Nuclear Information System (INIS)

    Nasimi, E.; Gabbar, H.A.

    2011-01-01

    Shutdown System 1 (SDS1) is a preferred method for a quick shutdown of nuclear fission process in CANDU (CANada Deuterium Uranium) reactor units. Failure of a routine SDS1 safety test during Fall 2009 outage resulted in the need to develop and execute a new methodology for Shutoff Rod inspection and re-evaluate the known degradation mechanisms and failure modes. This paper describes the development of this methodology and the obtained results. It also proposes several alternative solutions for the future performance analysis and maintenance/inspection optimization for SDS1 Shutoff Rods based on the Bruce Power Unit-3 Shutoff Rod 5 case study. (author)

  3. Analysis of log rate noise in Ontario's CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Hinds, H.W. [Dynamic Simulation and Analysis Corp., Deep River, Ontario (Canada); Banica, C.; Arguner, D. [Ontario Power Generation, Ajax, Ontario (Canada); Scharfenberg, R. [Bruce Power, Tiverton, Ontario (Canada)

    2007-07-01

    In the fall of 2003, the operators noticed that in the recently-refurbished Bruce A Shutdown System no. 1 (SDS1) the noise level in Log Rate signals were much larger than before. At the request of the Canadian Nuclear Safety Commission (CNSC), all Canadian CANDU reactors took action to characterize their Log Rate noise. Staff of the Inspection and Maintenance Services division of Ontario Power Generation (OPG) has collected high-speed high-accuracy noise data from nearly all 16 Ontario reactors, either as part of routine measurements before planned outages or as a dedicated noise recording. This paper gives the results of examining a suitable subset of this data, with respect to the characteristics and possible causes of Log Rate noise. The reactor and instrumentation design is different at each station: the locations of the moderator injection nozzles, the location of the ion chambers for each system, and the design of the Log Rate amplifiers. It was found that the Log noise (source of Log Rate noise) was much larger for those ion chambers in the path of the moderator injection nozzles, compared to those which were not in the path. This 'extra' Log noise would then be either attenuated or amplified depending on the transfer function (time constants) of the Log Rate amplifier. It was also observed that most of the Log and Log Rate noise is independent of any other signal measured. Although all CANDU reactors in Ontario have Log and Log Rate noise, the Bruce A SDS1 system has the largest amount of Log Rate noise, because (a) its SDS1 (and RRS) ion chambers are at the top of the reactor in the path of the moderator injection nozzles, and (b) its SDS1 Log Rate amplifiers have the smallest time constants. (author)

  4. Reactor core flow measurements during plant start-up using non-intrusive flow meter CROSSFLOW

    Energy Technology Data Exchange (ETDEWEB)

    Kanda, V.; Sharp, B.; Gurevich, A., E-mail: vkanda@amag-inc.com, E-mail: bsharp@amag-inc.com, E-mail: agurevich@amag-inc.com [Advanced Measurement & Analysis Group Inc., Ontario (Canada); Gurevich, Y., E-mail: yuri.gurevich@daystartech.ca [Daystar Technologies Inc., Ontario (Canada); Selvaratnarajah, S.; Lopez, A., E-mail: sselvaratnarajah@amag-inc.com, E-mail: alopez@amag-inc.com [Advanced Measurement & Analysis Group Inc., Ontario (Canada)

    2013-07-01

    For the first time, direct measurements of the total reactor coolant flow and the flow distribution between the inner reactor zone and the outer zone were conducted using the non-intrusive clamp on ultrasonic cross-correlation flow meter, CROSSFLOW, developed and manufactured by Advanced Measurement & Analysis Group Inc. (AMAG). The measurements were performed at Bruce Power A Unit 1 on the Pump Discharge piping of the Primary Heat Transport (PHT) system during start-up. This paper describes installation processes, hydraulic testing, uncertainty analysis and traceability of the measurements to certified standards. (author)

  5. Estimating the number of latent cracks in pressure tube joints at Bruce unit 2

    International Nuclear Information System (INIS)

    Schwarz, C.J.

    1983-10-01

    A model was built to estimate the number of hydride cracks which might have arisen in the rolled joints of Bruce unit 2 prior to the stress relieving operation. The model estimated that about 100 such cracks might exist. Since this estimate is based on experiments that were thermally cycled and since cycling did not occur in Bruce, prior to stress relieving the actual number is expected to be substantially lower. A sensitivity analysis of the model showed that it is sensitive to the assumptions of stress levels, probability of initiation and distribution of initiation time. A better estimate could be made if more data were available on these parameters under realistic conditions. Therefore, the recommendation is made to collect more information about these factors under realistic conditions

  6. Characterisation of reactor control rod drives. Specification 1-6

    International Nuclear Information System (INIS)

    1975-03-01

    The committee 'Kernreaktorregelung' of VDI/VDE-Gesellschaft Mess- und Regelungstechnik has developed 6 specifications (Typenblaetter) of reactor control rod drives. The specifications are aimed at giving engineers in reactor control systems an outline concerning the function as well as some construction characteristics. (orig./LN) [de

  7. Radioactive effluents from CANDU 6 reactors during normal operation

    International Nuclear Information System (INIS)

    Boss, C.R.; Allsop, P.J.

    1995-12-01

    During routine operation of a CANDU 6 reactor, various gaseous, liquid, and solid radioactive wastes are generated. The layout of the CANDU 6 reactor and the design of its systems ensure that these are minimized, but small quantities of gaseous and liquid wastes are continually discharged at very low concentrations. This report discusses the make-up of these chronically generated gaseous and liquid effluents. From a safety perspective, the doses to individual members of the public resulting from radioactive wastes chronically discharged from CANDU 6 reactors have been negligible. Similarly, doses to the regional and global populations have been negligible, generally less than 0.001% of background. While far below regulatory limits, releases of tritium, noble gases and gross β - -γ have been the most radiologically significant emissions, while radioiodine and particulates have had the greatest potential to deliver public dose. (author). 8 refs., 16 tabs., 3 figs

  8. Exercise capacity in Dutch children : New reference values for the Bruce treadmill protocol

    NARCIS (Netherlands)

    M.H.M. van der Cammen-van Zijp (Monique); H.J.G. van den Berg-Emons (Rita); S.P. Willemsen (Sten); H.J. Stam (Henk); D. Tibboel (Dick); H. IJsselstijn (Hanneke)

    2010-01-01

    textabstractThe Bruce treadmill protocol is suitable for children 4 years of age and older. Dutch reference values were established in 1987. We considered that children's exercise capacity has deteriorated due to changes in physical activity patterns and eating habits. We determined new reference

  9. Industrial process heat from CANDU reactors

    International Nuclear Information System (INIS)

    Hilborn, J.S.; Seddon, W.A.; Barnstaple, A.G.

    1980-08-01

    It has been demonstrated on a large scale that CANDU reactors can produce industrial process steam as well as electricity, reliably and economically. The advantages of cogeneration have led to the concept of an Industrial Energy Park adjacent to the Bruce Nuclear Power Development in the province of Ontario. For steam demands between 300,000 and 500,00 lb/h (38-63 kg/s) and an annual load factor of 80%, the estimated cost of nuclear steam at the Bruce site boundary is $3.21/MBtu ($3.04GJ), which is at least 30% cheaper than oil-fired steam at the same site. The most promising near term application of nuclear heat is likely to be found within the energy-intensive chemical industry. Nuclear energy can substitute for imported oil and coal in the eastern provinces if the price remains competitive, but low cost coal and gas in the western provinces may induce energy-intensive industries to locate near those sources of energy. In the long term it may be feasible to use nuclear heat for the mining and extraction of oil from the Alberta tar sands. (auth)

  10. AECB staff annual report of Bruce A NGS for the year 1991

    International Nuclear Information System (INIS)

    1992-11-01

    In this report on Bruce A operations during 1991, AECB staff itemizes non-compliances with the operating licence. Non of the violations that occurred at Bruce A resulted in any significant threat to public safety or well-being. There were no exposures of workers to radiation in excess of the regulatory requirements; however, there have been instances of uncontrolled contaminated areas and spread of contamination in the station. Releases of radioactive material to the environment were much below target. The performance of the four special safety systems has been good, with the exception of shutdown system number two on Unit 3. A review of significant event reports and their causes has revealed an apparent lack of a system by which operations and maintenance work is verified as having been carried out correctly. There is a large backlog of maintenance work. Initiatives have been taken to correct this problem. Two important safety issues are discussed in detail. These are the chronic problem of leaking boiler tubes, and the potentially serious problem of fret marks on pressure tubes caused by abnormal fuel support. (Author)

  11. VVANTAGE 6 - an advanced fuel assembly design for VVER reactors

    International Nuclear Information System (INIS)

    Doshi, P.K.; DeMario, E.E.; Knott, R.P.

    1993-01-01

    Over the last 25 years, Westinghouse fuel assemblies for pressurized water reactors (PWR's) have undergone significant changes to the current VANTAGE 5. VANTAGE 5 PWR fuel includes features such as removable top nozzles, debris filter bottom nozzles, low-pressure-drop zircaloy grids, zircaloy intermediate flow mixing grids, optimized fuel rods, in-fuel burnable absorbers, and increased burnup capability to region average values of 48000 MWD/MTU. These features have now been adopted to the VVER reactors. Westinghouse has completed conceptual designs for an advanced fuel assembly and other core components for VVER-1000 reactors known as VANTAGE 6. This report describes the VVANTAGE 6 fuel assembly design

  12. The EC6 - an enhanced mid-sized reactor with fuel cycle applications

    International Nuclear Information System (INIS)

    Soulard, M.; Yu, S.; Hopwood, J.; Hastings, I.J.

    2011-01-01

    Atomic Energy of Canada Limited (AECL) has two CANDU reactor products matched to markets: the Enhanced CANDU 6 (EC6), a modern 700 MWe-class design, and the Advanced CANDU Reactor (ACR-1000), a 1200 MWe-class Gen III+ design. Both reactor types are designed to meet both market-, and customer-driven needs; the ACR-1000 design is 90% complete and market-ready. The EC6 incorporates the CANDU 6's well-proven features, and adds enhancements that make the reactor even safer and easier to operate. The EC6 is the only mid-sized reactor with a proven pedigree that meets modern reactor expectations and regulatory standards. It is sized for smaller grids and also has outstanding fuel-cycle capability. The EC6 has domestic and offshore market pull and is the current focus of AECL's development program; market interest in the ACR-1000 is anticipated in the longer term. Some of the key features incorporated into the EC6 include upgrading containment and seismic capability to meet modern standards, shortening the overall project schedule, addressing obsolescence issues, optimizing maintenance outages and incorporating lessons learnt through feedback obtained from the operating plants. The EC6 utilizes modern computers and a distributed control system housed in an advanced control room which, along with automated testing and on-line diagnostics, make the plant easier and safer to operate, with minimal operator intervention. The first deployment of the EC6 is anticipated in Canada; off-shore markets are also being pursued. The EC6 burns natural uranium as standard. But, high neutron economy, on-power refuelling, a simple fuel bundle, and the fundamental CANDU fuel channel design provide the EC6 with the flexibility to accommodate a range of advanced fuels. (author)

  13. Enhanced candu 6 reactor: status

    International Nuclear Information System (INIS)

    Azeez, S.; Girouard, P.

    2006-01-01

    The CANDU 6 power reactor is visionary in its approach, renowned for its on-power refuelling capability and proven over years of safe, economical and reliable power production. Developed by Atomic Energy of Canada Limited (AECL), the CANDU 6 design offers excellent performance utilizing state-of-the-art technology. The first CANDU 6 plants went into service in the early 1980s as leading edge technology and the design has been continuously advanced to maintain superior performance with an outstanding safety record. The first set of CANDU 6 plants - Gentilly 2 and Point Lepreau in Canada, Embalse in Argentina and Wolsong- Unit 1 in Korea - have been in service for more than 22 years and are still producing electricity at peak performance; to the end of 2004, their average Lifetime Capacity Factor was 83.2%. The newer CANDU 6 units in Romania (Cernavoda 1), Korea (Wolsong-Units 2, 3 and 4) and Qinshan (Phase III- Units 1 and 2) have also been performing at outstanding levels. The average lifetime Capacity Factor of the 10 CANDU 6 operating units around the world has been 87% to the end of 2004. Building on these successes, AECL is committed to the further development of this highly successful design, now focussing on meeting customers' needs for reduced costs, further improvements to plant operation and performance, enhanced safety and incorporating up-to-date technology, as warranted. This has resulted in AECL embarking on improving the CANDU 6 design through an upgraded product termed the ''Enhanced CANDU 6'' (EC6), which incorporates several attractive but proven features that make the CANDU 6 reactor even more economical, safer and easier to operate. Some of the key features that are being incorporated into the EC6 include increasing the plant's power output, shortening the overall project schedule, decreasing the capital cost, dealing with obsolescence issues, optimizing maintenance outages and incorporating lessons learnt through feedback obtained from the

  14. Bruce Unit 2 lay-up engineering assessment

    International Nuclear Information System (INIS)

    Iley, D.

    1995-01-01

    The overall lay-up program initiated as a result of the strategic decision to shut down Bruce A unit 2 is briefly described as an introduction to the engineering assessment of the unit 2 systems. The assessment has identified the need to prepare 67 system and 9 equipment lay-up specifications. A summary of the selected system specifications is described. A complete summary and the specifications and the status of unit 2 systems and equipment required to support lay-up and/or the other three operating units is available on request due to the volume of the information. Some logistical details of the lay-up implementation plans, results, and problems to date demonstrate the complexity of the lay-up requirements for a nuclear unit in a multi-unit CANDU station. (author)

  15. Regional and site geological frameworks : proposed Deep Geologic Repository, Bruce County, Ontario

    Energy Technology Data Exchange (ETDEWEB)

    Raven, K.; Sterling, S.; Gaines, S.; Wigston, A. [Intera Engineering Ltd., Ottawa, ON (Canada); Frizzell, R. [Nuclear Waste Management Organization, Toronto, ON (Canada)

    2009-07-01

    The Nuclear Waste Management Organization is conducting geoscientific studies on behalf of Ontario Power Generation into the proposed development of a Deep Geologic Repository (DGR) for low and intermediate level radioactive waste (L and ILW) at the Bruce site, near Tiverton, Ontario. This paper presented a regional geological framework for the site that was based on a review of regional drilling; structural geology; paleozoic stratigraphy and sedimentology; a 3D geological framework model; a DGR geological site characterization model; bedrock stratigraphy and marker beds; natural fracture frequency data; and formation predictability. The studies have shown that the depth, thickness, orientation and rock quality of the 34 rock formations, members or units that comprise the 840 m thick Paleozoic bedrock sequence at the Bruce site are very uniform and predictable over distances of several kilometres. The proposed DGR will be constructed as an engineered facility comprising a series of underground emplacement rooms at a depth of 680 metres below ground within argillaceous limestones. The geoscientific studies are meant to provide a basis for the development of descriptive geological, hydrogeological and geomechanical models of the DGR site that will facilitate environmental and safety assessments. 11 refs., 3 tabs., 9 figs.

  16. Kuldlõvid Louise Bourgeois'le, Bruce Naumanile ja Itaalia paviljonile / Reet Varblane

    Index Scriptorium Estoniae

    Varblane, Reet, 1952-

    1999-01-01

    Veneetsia 48. rahvusvahelise kunstibiennaali preemiasaajad, premeeritud tööd, korralduskomitee ja žürii koosseis. Kuldlõvid: Louise Bourgeois, Bruce Nauman, Itaalia paviljon (Monica Bonvicini, Bruna Esposito, Luisa Lambri, Paola Pivi, Grazia Toderi ühisprojekt); kolm rahvusvahelist preemiat: Doug Aitken, Cai Gou-Qiang, Shirin Neshat; žürii tõstis esile: Georges Abeagbo, Eija-Liisa Ahtila, Katarzyna Kozura ? (Kozyra), Lee Bul; UNESCO preemia: Ghada Amer

  17. After reliability centred maintenance. Preventive maintenance living program implementation at Bruce Power

    International Nuclear Information System (INIS)

    Harazim, Michael L.; Ferguson, Brian J.

    2003-01-01

    Industrial preventive maintenance (PM) programs represent a large part of plant O and M costs. PM Optimization (PMO) projects represent an effective mechanism for identifying unnecessary PM, extending PM intervals and infusing predictive maintenance (PdM) methods. However, once optimized, what process prevents the PM program from returning to a state of disarray? This is the function of a PM living program (PMLP). In 1997, an independent performance assessment identified concerns with the applicability and effectiveness of all Ontario Power Generation, Inc. (OPGI) PM programs. In response, OPGI instituted an Integrated Maintenance Program (IMP) including Reliability Centred Maintenance (RCM) and a PMLP. It should be noted that the PMLP was developed for the 3 OPGI nuclear Sites (i.e. Bruce, Pickering, and Darlington). Effective 1 May 2001, the Bruce Site has been leased to a group of investors lead by British Energy. This paper is written in historical context and therefore refers to the Bruce Site as part of OPGI. The PMLP is made up of five elements: 1) process control, 2) change control, 3) worker feedback, 4) program performance metrics, and 5) deferral module. A PMLP software tool, originally applied to Duke Energy nuclear plants, was enhanced and customized specifically for the OPGI PMLP, and then implemented at all three of OPGI's nuclear sites. The objective of the OPGI PMLP was to: Provide processes/procedures for continual optimization of all site PM tasks, Ensure effective and timely revision of PM tasks in the work management system, Ensure PM tasks remain applicable/effective at all times, Maintain and enhance PM consistency on a component, system and Site basis, Ensure that new predictive maintenance techniques are applied and integrated with the PM program, Ensure that mandated PM tasks are identified and executed, Provide a mechanism for craft feedback, Meet regulatory requirements for PM program effectiveness, and Provide PM task deferral

  18. R. Bruce Merrifield and Solid-Phase Peptide Synthesis: A Historical Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, A R

    2007-12-04

    Bruce Merrifield, trained as a biochemist, had to address three major challenges related to the development and acceptance of solid-phase peptide synthesis (SPPS). The challenges were (1) to reduce the concept of peptide synthesis on a insoluble support to practice, (2) overcome the resistance of synthetic chemists to this novel approach, and (3) establish that a biochemist had the scientific credentials to effect the proposed revolutionary change in chemical synthesis. How these challenges were met is discussed in this article.

  19. Reactor physics verification of the MCNP6 unstructured mesh capability

    International Nuclear Information System (INIS)

    Burke, T. P.; Kiedrowski, B. C.; Martz, R. L.; Martin, W. R.

    2013-01-01

    The Monte Carlo software package MCNP6 has the ability to transport particles on unstructured meshes generated from the Computed-Aided Engineering software Abaqus. Verification is performed using benchmarks with features relevant to reactor physics - Big Ten and the C5G7 computational benchmark. Various meshing strategies are tested and results are compared to reference solutions. Computational performance results are also given. The conclusions show MCNP6 is capable of producing accurate calculations for reactor physics geometries and the computational requirements for small lattice benchmarks are reasonable on modern computing platforms. (authors)

  20. Reactor physics verification of the MCNP6 unstructured mesh capability

    Energy Technology Data Exchange (ETDEWEB)

    Burke, T. P. [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, 2355 Bonisteel Boulevard, Ann Arbor, MI 48109 (United States); Kiedrowski, B. C.; Martz, R. L. [X-Computational Physics Division, Monte Carlo Codes Group, Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States); Martin, W. R. [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, 2355 Bonisteel Boulevard, Ann Arbor, MI 48109 (United States)

    2013-07-01

    The Monte Carlo software package MCNP6 has the ability to transport particles on unstructured meshes generated from the Computed-Aided Engineering software Abaqus. Verification is performed using benchmarks with features relevant to reactor physics - Big Ten and the C5G7 computational benchmark. Various meshing strategies are tested and results are compared to reference solutions. Computational performance results are also given. The conclusions show MCNP6 is capable of producing accurate calculations for reactor physics geometries and the computational requirements for small lattice benchmarks are reasonable on modern computing platforms. (authors)

  1. Leak detection capability in CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Azer, N.; Barber, D.H.; Boucher, P.J. [and others

    1997-04-01

    This paper addresses the moisture leak detection capability of Ontario Hydro CANDU reactors which has been demonstrated by performing tests on the reactor. The tests confirmed the response of the annulus gas system (AGS) to the presence of moisture injected to simulate a pressure tube leak and also confirmed the dew point response assumed in leak before break assessments. The tests were performed on Bruce A Unit 4 by injecting known and controlled rates of heavy water vapor. To avoid condensation during test conditions, the amount of moisture which could be injected was small (2-3.5 g/hr). The test response demonstrated that the AGS is capable of detecting and annunciating small leaks. Thus confidence is provided that it would alarm for a growing pressure tube leak where the leak rate is expected to increase to kg/hr rapidly. The measured dew point response was close to that predicted by analysis.

  2. Leak detection capability in CANDU reactors

    International Nuclear Information System (INIS)

    Azer, N.; Barber, D.H.; Boucher, P.J.

    1997-01-01

    This paper addresses the moisture leak detection capability of Ontario Hydro CANDU reactors which has been demonstrated by performing tests on the reactor. The tests confirmed the response of the annulus gas system (AGS) to the presence of moisture injected to simulate a pressure tube leak and also confirmed the dew point response assumed in leak before break assessments. The tests were performed on Bruce A Unit 4 by injecting known and controlled rates of heavy water vapor. To avoid condensation during test conditions, the amount of moisture which could be injected was small (2-3.5 g/hr). The test response demonstrated that the AGS is capable of detecting and annunciating small leaks. Thus confidence is provided that it would alarm for a growing pressure tube leak where the leak rate is expected to increase to kg/hr rapidly. The measured dew point response was close to that predicted by analysis

  3. Hydrogeological evidence of low rock mass permeabilities in ordovician strata: Bruce nuclear site

    International Nuclear Information System (INIS)

    Beauheim, R.L.; Roberts, R.M.; Avis, J.D.; Heagle, D.

    2011-01-01

    One of the key attributes contributing to the suitability of the Bruce nuclear site to host a Deep Geologic Repository (DGR) for Low and Intermediate Level Waste (L&ILW) is the low permeability of the Ordovician host rock and of the overlying and underlying strata. The permeability of these rocks is so low that diffusion is a much more significant transport mechanism than advection. Hydrogeological evidence for the low permeability of the Ordovician strata comes from two principal sources, direct and indirect. Direct evidence of low permeability is provided by the hydraulic testing performed in deep boreholes, DGR-2 through DGR-6. Straddle-packer hydraulic testing was performed in 57 Ordovician intervals in these five holes. The testing provided continuous coverage using ~30-m straddle intervals of the Ordovician strata exposed in boreholes DGR-2, DGR-3, DGR-4, and DGR-5, while testing was targeted on discontinuous 10.2-m intervals in DGR-6. The average horizontal hydraulic conductivities of these intervals determined from the tests ranged from 2E-16 to 2E-10 m/s. The Lower Member of the Cobourg Formation, which is the proposed host formation for the DGR, was found to have a horizontal hydraulic conductivity of 4E-15 to 3E-14 m/s. The only horizontal hydraulic conductivity values measured that were greater than 2E-12 m/s are from the Black River Group, located at the base of the Ordovician sedimentary sequence. Indirect evidence of low permeability is provided by the observed distribution of hydraulic heads through the Ordovician sequence. Hydraulic head profiles, defined by hydraulic testing and confirmed by Westbay multilevel monitoring systems, show significant underpressures relative to a density-compensated hydrostatic condition throughout most of the Ordovician strata above the Black River Group, whereas the Black River Group is overpressured. Pressure differences of 1 MPa or more are observed between adjacent intervals in the boreholes. The observed

  4. Validation of DRAGON side-step method for Bruce-A restart Phase-B physics tests

    International Nuclear Information System (INIS)

    Shen, W.; Ngo-Trong, C.; Davis, R.S.

    2004-01-01

    The DRAGON side-step method, developed at AECL, has a number of advantages over the all-DRAGON method that was used before. It is now the qualified method for reactivity-device calculations. Although the side-step-method-generated incremental cross sections have been validated against those previously calculated with the all-DRAGON method, it is highly desirable to validate the side-step method against device-worth measurements in power reactors directly. In this paper, the DRAGON side-step method was validated by comparison with the device-calibration measurements made in Bruce-A NGS Unit 4 restart Phase-B commissioning in 2003. The validation exercise showed excellent results, with the DRAGON code overestimating the measured ZCR worth by ∼5%. A sensitivity study was also performed in this paper to assess the effect of various DRAGON modelling techniques on the incremental cross sections. The assessment shows that the refinement of meshes in 3-D and the use of the side-step method are two major reasons contributing to the improved agreement between the calculated ZCR worths and the measurements. Use of different DRAGON versions, DRAGON libraries, local-parameter core conditions, and weighting techniques for the homogenization of tube clusters inside the ZCR have a very small effect on the ZCR incremental thermal absorption cross section and ZCR reactivity worth. (author)

  5. Steam generator leak detection at Bruce A Unit 1

    International Nuclear Information System (INIS)

    Maynard, K.J.; McInnes, D.E.; Singh, V.P.

    1997-01-01

    A new steam generator leak detection system was recently developed and utilized at Bruce A. The equipment is based on standard helium leak detection, with the addition of moisture detection and several other capability improvements. All but 1% of the Unit 1 Boiler 03 tubesheet was inspected, using a sniffer probe which inspected tubes seven at a time and followed by individual tube inspections. The leak search period was completed in approximately 24 hours, following a prerequisite period of several days. No helium leak indications were found anywhere on the boiler. A single water leak indication was found, which was subsequently confirmed as a through-wall defect by eddy current inspection. (author)

  6. Fighting with Reality: Considering Mark Johnson's Pragmatic Realism through Bruce Lee's Jeet Kune Do Method

    Science.gov (United States)

    Miller, Alexander David

    2015-01-01

    This dissertation considers the supportive and complementary relation between Mark Johnson's embodied realism and Bruce Lee's Jeet Kune Do as a philosophical practice. In exploring this relationship, the emphasis on one's embodiment condition and its relationship with metaphor and self-expression are the primary focus. First, this work involves…

  7. White spots on Smoke rings by Bruce Nauman: a case study on contemporary art conservation using microanalytical techniques.

    Science.gov (United States)

    Mafalda, Ana Cardeira; da Câmara, Rodrigo Bettencourt; Strzelec, Patrick; Schiavon, Nick; Mirão, José; Candeias, António; Carvalho, Maria Luísa; Manso, Marta

    2015-02-01

    The artwork "Smoke Rings: Two Concentric Tunnels, Non-Communicating" by Bruce Nauman represents a case study of corrosion of a black patina-coated Al-alloy contemporary artwork. The main concern over this artwork was the widespread presence of white spots on its surface. Alloy substrate, patina, and white spots were characterized by means of energy-dispersive X-ray fluorescence and scanning electron microscopy with energy-dispersive spectroscopy. Alloy substrate was identified as an aluminum alloy 6,000 series Al-Si-Mg. Patina's identified composition confirmed the documentation provided by the atelier. Concerning the white spots, zircon particles were found on patina surface as external elements.

  8. Impact of the 37M fuel design on reactor physics characteristics

    International Nuclear Information System (INIS)

    Perez, R.; Ta, P.

    2013-01-01

    For CANDU nuclear reactors, aging of the Heat Transport System (HTS) leads to, among other effects, a reduction on the Critical Heat Flux (CHF) and dryout margin. In an effort to mitigate the impact of aging of the HTS on safety margins, Bruce Power is introducing a design change to the standard 37-element fuel bundle known as the modified 37-element fuel bundle, or 37M for short. As part of the overall design change process it was necessary to assess the impact of the modified fuel bundle design on key reactor physics parameters. Quantification of this impact on lattice cell properties, core reactivity properties, etc., was reached through a series of calculations using state-of-the-art lattice and core physics models, and comparisons against results for the standard fuel bundle. (author)

  9. Steam generator cleaning campaigns at Bruce A: 1993-1996

    International Nuclear Information System (INIS)

    Puzzuoli, F.V.; Leinonen, P.J.; Lowe, G.A.

    1997-01-01

    Boiler chemical cleaning (BOCC) and high-pressure water lancing operations were performed during the Bruce A 1993 Unit 3, 1994 Unit 3, 1995 Unit 1 and 1996 Unit 3 outages to remove secondary side deposits. High-pressure water lancing focused on three boiler areas: tube support plates, to remove broached hole deposits, hot leg U-bend supports to dislodge deposits contributing to boiler tube stress corrosion cracking and tube sheets with the aim of removing accumulated sludge piles and post BOCC insoluble residues. The chemical cleaning processes applied were modified versions of the one developed by the Electric Power Research Institute/Steam Generator Owners Group. During these BOCC operations, corrosion for several key boiler materials was monitored and was well below the specified allowances

  10. Preventive maintenance: optimization of time - based discard decisions at the bruce nuclear generating station

    International Nuclear Information System (INIS)

    Doyle, E.K.; Jardine, A.K.S.

    2001-01-01

    The use of various maintenance optimization techniques at Bruce has lead to cost effective preventive maintenance applications for complex systems. As previously reported at ICONE 6 in New Orleans, 1996, several innovative practices reduced Reliability Centered Maintenance costs while maintaining the accuracy of the analysis. The optimization strategy has undergone further evolution and at the present an Integrated Maintenance Program (IMP) is in place where an Expert Panel consisting of all players/experts proceed through each system in a disciplined fashion and reach agreement on all items under a rigorous time frame. It is well known that there are essentially 3 maintenance based actions that can flow from a Maintenance Optimization Analysis: condition based maintenance, time based maintenance and time based discard. The present effort deals with time based discard decisions. Maintenance data from the Remote On-Power Fuel Changing System was used. (author)

  11. Phytotoxicology section investigation in the vicinity of the Bruce Nuclear Power Development, the Pickering Nuclear Generating Station and the Darlington Nuclear Generating Station, in October, 1989

    International Nuclear Information System (INIS)

    1991-02-01

    The Phytotoxicology Section, Air Resources Branch is a participant in the Pickering and Bruce Nuclear Contingency Plans. The Phytotoxicology Emergency Response Team is responsible for collecting vegetation samples in the event of a nuclear emergency at any of the nuclear generating stations in the province. As part of its responsibility the Phytotoxicology Section collects samples around the nuclear generating stations for comparison purposes in the event of an emergency. Because of the limited frequency of sampling, the data from the surveys are not intended to be used as part of a regulatory monitoring program. These data represent an effort by the MOE to begin to establish a data base of tritium concentrations in vegetation. The Phytotoxicology Section has carried out seven surveys in the vicinity of Ontario Hydro nuclear generating stations since 1981. Surveys were conducted for tritium in snow in the vicinity of Bruce Nuclear Power Development (BNPD), February, 1981; tritium in cell-free water of white ash in the vicinity of BNPD, September, 1981; tritium in snow in the vicinity of BNPD, March, 1982; tritium in tree sap in the vicinity of BNPD, April, 1982; tritium in tree sap in the vicinity of BNPD, April, 1984, tritium in the cell-free water of white ash in the vicinity of BNPD, September, 1985; and, tritium in cell-free water of grass in the vicinity of Pickering Nuclear Generation Station (PNGS), October 1986. In all cases a pattern of decreasing tritium levels with increasing distance from the stations was observed. In October, 1989, assessment surveys were conducted around Bruce Nuclear Power Development, the Pickering Nuclear Generating Station and the new Darlington Nuclear Generating Station (DNGS). The purpose of these surveys was to provide baseline data for tritium in cell-free water of grass at all three locations at the same time of year. As none of the reactor units at DNGS had been brought on line at the time of the survey, this data was to be

  12. Explorability and predictability of the paleozoic sedimentary sequence beneath the Bruce nuclear site

    International Nuclear Information System (INIS)

    Parmenter, A.; Jensen, M.; Crowe, R.; Raven, K.

    2011-01-01

    Ontario Power Generation (OPG) is proposing to develop a Deep Geologic Repository (DGR) for the long-term management of its Low and Intermediate Level Waste (L&ILW) at the Bruce nuclear site located in the Municipality of Kincardine, Ontario. A 4-year program of geoscientific studies to assess the suitability of the 850 m thick Palaeozoic age sedimentary sequence beneath the site to host the DGR was completed in 2010. The studies provide evidence of a geologic setting in which the DGR concept would be safely implemented at a nominal depth of 680 m within the argillaceous limestone of the Cobourg Formation. This paper describes the geologic framework of the Bruce nuclear site with a focus on illustrating the high degree of stratigraphic continuity and traceability at site-specific and regional scales within the Ordovician sediments proposed to host and enclose the DGR. As part of the site-specific studies, a program of deep drilling/coring (6 boreholes) and in-situ testing through the sedimentary sequence was completed from 4 drill sites situated beyond the DGR footprint, approximately 1 km apart. Core logging reveals that the stratigraphic sequence comprises 34 distinct bedrock formations/members/units consistent with the known regional stratigraphic framework. These layered sedimentary formations dip 0.6 o (~10 m/km) to the southwest with highly uniform thicknesses both at the site- and regional-scale, particularly, the Ordovician sediments, which vary on the order of metres. The occurrence of steeply-dipping faults within the sedimentary sequence is not revealed through surface outcrop fracture mapping, micro-seismic (M ≥ 1) monitoring, inclined borehole coring or intersection of hydrothermal type dolomitized reservoir systems. Potential fault structures, interpreted from a 2-D seismic survey, were targeted by angled boreholes which found no evidence for their existence. Formation specific continuity is also evidence by the lateral traceability of physical rock

  13. Review of Ontario Hydro Pickering 'A' and Bruce 'A' nuclear generating stations' accident analyses

    International Nuclear Information System (INIS)

    Serdula, K.J.

    1988-01-01

    Deterministic safety analysis for the Pickering 'A' and Bruce 'A' nuclear generating stations were reviewed. The methodology used in the evaluation and assessment was based on the concept of 'N' critical parameters defining an N-dimensional safety parameter space. The reviewed accident analyses were evaluated and assessed based on their demonstrated safety coverage for credible values and trajectories of the critical parameters within this N-dimensional safety parameter space. The reported assessment did not consider probability of occurrence of event. The reviewed analyses were extensive for potential occurrence of accidents under normal steady-state operating conditions. These analyses demonstrated an adequate assurance of safety for the analyzed conditions. However, even for these reactor conditions, items have been identified for consideration of review and/or further study, which would provide a greater assurance of safety in the event of an accident. Accident analyses based on a plant in a normal transient operating state or in an off-normal condition but within the allowable operating envelope are not as extensive. Improvements in demonstrations and/or justifications of safety upon potential occurrence of accidents would provide further assurance of adequacy of safety under these conditions. Some events under these conditions have not been analyzed because of their judged low probability; however, accident analyses in this area should be considered. Recommendations are presented relating to these items; it is also recommended that further study is needed of the Pickering 'A' special safety systems

  14. Uncertainties in gas dispersion at the Bruce heavy water plant

    International Nuclear Information System (INIS)

    Alp, E.; Ciccone, A.

    1995-07-01

    There have been concerns regarding the uncertainties in atmospheric dispersion of gases released from the Bruce Heavy Water Plant (BHWP). The concern arises due to the toxic nature of H 2 S, and its combustion product SO 2 . In this study, factors that contribute to the uncertainties, such as the effect of the shoreline setting, the potentially heavy gas nature of H 2 S releases, and concentration fluctuations, have been investigated. The basic physics of each of these issues has been described along with fundamental modelling principles. Recommendations have been provided on available computer models that would be suitable for modelling gas dispersion in the vicinity of the BHWP. (author). 96 refs., 4 tabs., 25 figs

  15. Uncertainties in gas dispersion at the Bruce heavy water plant

    Energy Technology Data Exchange (ETDEWEB)

    Alp, E; Ciccone, A [Concord Environmental Corp., Downsview, ON (Canada)

    1995-07-01

    There have been concerns regarding the uncertainties in atmospheric dispersion of gases released from the Bruce Heavy Water Plant (BHWP). The concern arises due to the toxic nature of H{sub 2}S, and its combustion product SO{sub 2}. In this study, factors that contribute to the uncertainties, such as the effect of the shoreline setting, the potentially heavy gas nature of H{sub 2}S releases, and concentration fluctuations, have been investigated. The basic physics of each of these issues has been described along with fundamental modelling principles. Recommendations have been provided on available computer models that would be suitable for modelling gas dispersion in the vicinity of the BHWP. (author). 96 refs., 4 tabs., 25 figs.

  16. Coffee Cups, Canoes, Airplanes and the Lived Experience: Reflections on the Works of Bertram (Chip) Bruce

    Science.gov (United States)

    Haythornthwaite, Caroline

    2014-01-01

    A career spent in research, teaching, and engagement with community entails a lifetime of assemblage of meaning from people, resources, technologies and experience. In his work, Bertram (Chip) Bruce has long engaged with how we create such an assemblage of meaning from our formal and found learning, and from the "lived experience" of…

  17. Development of restriction enzyme analyses to distinguish winter moth from bruce spanworm and hybrids between them

    Science.gov (United States)

    Marinko Sremac; Joseph Elkinton; Adam. Porter

    2011-01-01

    Elkinton et. al. recently completed a survey of northeastern North America for the newly invasive winter moth, Operophtera brumata L. The survey used traps baited with the winter moth pheromone, which consists of a single compound also used by Bruce spanworm, O. bruceata (Hulst), the North American congener of winter moth. Our...

  18. Bundle 13 position verification tool description and on-reactor use

    Energy Technology Data Exchange (ETDEWEB)

    Onderwater, T G [Canadian General Electric Co. Ltd., Peterborough, ON (Canada)

    1997-12-31

    To address the Power Pulse problem, Bruce B uses Gap: a comprehensive monitoring program by the station to maintain the gap between the fuel string and the upstream shield plug. The gap must be maintained within a band. The gap must not be so large as to allow excessive reactivity increases or cause high impact forces during reverse flow events. It should also not be so small as to cause crushed fuel during rapid, differential reactor/fuel string cool downs. Rapid cool downs are infrequent. The Bundle 13 Position Verification Tool (BPV tool) role is to independently measure the position of the upstream bundle of the fuel string. The measurements are made on-reactor, on-power and will allow verification of the Gap Management system`s calculated fuel string position. This paper reviews the reasons for developing the BPV tool. Design issues relevant to safe operation in the fuelling machine, fuel channel and fuel handling equipment are also reviewed. Tests ensuring no adverse effects on channel pressure losses are described and actual on-reactor, on-power results are discussed. (author). 4 figs.

  19. Bundle 13 position verification tool description and on-reactor use

    International Nuclear Information System (INIS)

    Onderwater, T.G.

    1996-01-01

    To address the Power Pulse problem, Bruce B uses Gap: a comprehensive monitoring program by the station to maintain the gap between the fuel string and the upstream shield plug. The gap must be maintained within a band. The gap must not be so large as to allow excessive reactivity increases or cause high impact forces during reverse flow events. It should also not be so small as to cause crushed fuel during rapid, differential reactor/fuel string cool downs. Rapid cool downs are infrequent. The Bundle 13 Position Verification Tool (BPV tool) role is to independently measure the position of the upstream bundle of the fuel string. The measurements are made on-reactor, on-power and will allow verification of the Gap Management system's calculated fuel string position. This paper reviews the reasons for developing the BPV tool. Design issues relevant to safe operation in the fuelling machine, fuel channel and fuel handling equipment are also reviewed. Tests ensuring no adverse effects on channel pressure losses are described and actual on-reactor, on-power results are discussed. (author). 4 figs

  20. Homogeneous fast reactor benchmark testing of CENDL-2 and ENDF/B-6

    International Nuclear Information System (INIS)

    Liu Guisheng

    1995-01-01

    How to choose correct weighting spectrum has been studied to produce multigroup constants for fast reactor benchmark calculations. A correct weighting option makes us obtain satisfying results of K eff and central reaction rate ratios for nine fast reactor benchmark testings of CENDL-2 and ENDF/B-6. (4 tabs., 2 figs.)

  1. Adapting Scott and Bruce's General Decision-Making Style Inventory to Patient Decision Making in Provider Choice.

    Science.gov (United States)

    Fischer, Sophia; Soyez, Katja; Gurtner, Sebastian

    2015-05-01

    Research testing the concept of decision-making styles in specific contexts such as health care-related choices is missing. Therefore, we examine the contextuality of Scott and Bruce's (1995) General Decision-Making Style Inventory with respect to patient choice situations. Scott and Bruce's scale was adapted for use as a patient decision-making style inventory. In total, 388 German patients who underwent elective joint surgery responded to a questionnaire about their provider choice. Confirmatory factor analyses within 2 independent samples assessed factorial structure, reliability, and validity of the scale. The final 4-dimensional, 13-item patient decision-making style inventory showed satisfactory psychometric properties. Data analyses supported reliability and construct validity. Besides the intuitive, dependent, and avoidant style, a new subdimension, called "comparative" decision-making style, emerged that originated from the rational dimension of the general model. This research provides evidence for the contextuality of decision-making style to specific choice situations. Using a limited set of indicators, this report proposes the patient decision-making style inventory as valid and feasible tool to assess patients' decision propensities. © The Author(s) 2015.

  2. Homogeneous fast reactor benchmark testing of CENDL-2 and ENDF/B-6

    International Nuclear Information System (INIS)

    Liu Guisheng

    1995-11-01

    How to choose correct weighting spectrum has been studied to produce multigroup constants for fast reactor benchmark calculations. A correct weighting option makes us obtain satisfying results of K eff and central reaction rate ratios for nine fast reactor benchmark testing of CENDL-2 and ENDF/B-6. (author). 8 refs, 2 figs, 4 tabs

  3. Expected changes in competency assurance at Bruce Power over next decade

    Energy Technology Data Exchange (ETDEWEB)

    Horton, C., E-mail: chip.horton@brucepower.com [Bruce Power, Tiverton, Ontario (Canada)

    2013-07-01

    There will be ten expected changes in competency assurance at Bruce Power over next decade. These changes are: outage worker supplemental staff change; entry level power worker union staff; self-paced process & software training; electronic confirmation of qualifications; JIT built into processes for low frequency tasks; more terminal objective back to fundamentals vs fundamentals build to terminal objective instructional design; more learning by practice / doing in a safe environment; SAT emphasis move from analysis, design & development to evaluation & maintenance of task lists (clearly tied to working rights); more formal tacit knowledge capture programs, systematic movement of knowledge from tacit to explicit; more breadth & depth training driven by demographic changes.

  4. Expected changes in competency assurance at Bruce Power over next decade

    International Nuclear Information System (INIS)

    Horton, C.

    2013-01-01

    There will be ten expected changes in competency assurance at Bruce Power over next decade. These changes are: outage worker supplemental staff change; entry level power worker union staff; self-paced process & software training; electronic confirmation of qualifications; JIT built into processes for low frequency tasks; more terminal objective back to fundamentals vs fundamentals build to terminal objective instructional design; more learning by practice / doing in a safe environment; SAT emphasis move from analysis, design & development to evaluation & maintenance of task lists (clearly tied to working rights); more formal tacit knowledge capture programs, systematic movement of knowledge from tacit to explicit; more breadth & depth training driven by demographic changes.

  5. Studies on the liquid fluoride thorium reactor: Comparative neutronics analysis of MCNP6 code with SRAC95 reactor analysis code based on FUJI-U3-(0)

    Energy Technology Data Exchange (ETDEWEB)

    Jaradat, S.Q., E-mail: sqjxv3@mst.edu; Alajo, A.B., E-mail: alajoa@mst.edu

    2017-04-01

    Highlights: • The verification for FUJI-U3-(0)—a molten salt reactor—was performed. • The MCNP6 was used to study the reactor physics characteristics for FUJI-U3 type. • The results from the MCNP6 were comparable with the ones obtained from literature. - Abstract: The verification for FUJI-U3-(0)—a molten salt reactor—was performed. The reactor used LiF-BeF2-ThF4-UF4 as the mixed liquid fuel salt, and the core was graphite moderated. The MCNP6 code was used to study the reactor physics characteristics for the FUJI-U3-(0) reactor. Results for reactor physics characteristic of the FUJI-U3-(0) exist in literature, which were used as reference. The reference results were obtained using SRAC95 (a reactor analysis code) coupled with ORIGEN2 (a depletion code). Some modifications were made in the reconstruction of the FUJI-U3-(0) reactor in MCNP due to unavailability of more detailed description of the reactor core. The assumptions resulted in two representative models of the reactor. The results from the MCNP6 models were compared with the reference results obtained from literature. The results were comparable with each other, but with some notable differences. The differences are because of the approximations that were done on the SRAC95 model of the FUJI-U3 to simplify the simulation. Based on the results, it is concluded that MCNP6 code predicts well the overall simulation of neutronics analysis to the previous simulation works using SRAC95 code.

  6. Online monitoring and diagnostic system on RA-6 nuclear reactor

    International Nuclear Information System (INIS)

    Garcia Peyrano, O. A.; Marticorena, M.; Koch, R. G.; Martinez, J. S; Berruti, G. E.; Nunez, W. M.; Gonzales, L. A.; Tarquini, L. D.; Sotelo, J. P

    2009-01-01

    This paper presents the Online Automatic Monitoring and Diagnostic System for mechanical components, installed on RA-6 Nuclear Reactor (San Carlos de Bariloche, Argentina). This system has been designed, installed and set-up by the Vibrations and Mechatronics Laboratory (Centro Atomico Bariloche, Comision Nacional de Energia Atomica) and Sitrack.com Argentina SA. This system provides an online mechanical diagnostic of the main reactor components, allowing incipient failures to be early detected and identified, avoiding unscheduled shut-downs and reducing maintenance times. The diagnostic is accomplished by an online analysis of the vibratory signature of the mechanical components, obtained by vibrations sensors on the main pump and the decay tank. The mechanical diagnostic and the main operational parameters are displayed on the reactor control room and published on the internet. [es

  7. Hourly and seasonable variation in catch of winter moths and bruce spanworm in pheromone-baited traps

    Science.gov (United States)

    Joseph Elkinton; Natalie Leva; George Boettner; Roy Hunkins; Marinko. Sremac

    2011-01-01

    Elkinton et al. recently completed a survey of northeastern North America for the newly invasive winter moth, Operophtera brumata L. The survey used traps baited with the winter moth pheromone, which, as far as it is known, consists of a single compound that is also used by Bruce spanworm, the North American congener of winter moth, O....

  8. THE IMPACT OF POWER COEFFICIENT OF REACTIVITY ON CANDU 6 REACTORS

    Directory of Open Access Journals (Sweden)

    D. KASTANYA

    2013-10-01

    Full Text Available The combined effects of reactivity coefficients, along with other core nuclear characteristics, determine reactor core behavior in normal operation and accident conditions. The Power Coefficient of Reactivity (PCR is an aggregate indicator representing the change in reactor core reactivity per unit change in reactor power. It is an integral quantity which captures the contributions of the fuel temperature, coolant void, and coolant temperature reactivity feedbacks. All nuclear reactor designs provide a balance between their inherent nuclear characteristics and the engineered reactivity control features, to ensure that changes in reactivity under all operating conditions are maintained within a safe range. The CANDU® reactor design takes advantage of its inherent nuclear characteristics, namely a small magnitude of reactivity coefficients, minimal excess reactivity, and very long prompt neutron lifetime, to mitigate the demand on the engineered systems for controlling reactivity and responding to accidents. In particular, CANDU reactors have always taken advantage of the small value of the PCR associated with their design characteristics, such that the overall design and safety characteristics of the reactor are not sensitive to the value of the PCR. For other reactor design concepts a PCR which is both large and negative is an important aspect in the design of their engineered systems for controlling reactivity. It will be demonstrated that during Loss of Regulation Control (LORC and Large Break Loss of Coolant Accident (LBLOCA events, the impact of variations in power coefficient, including a hypothesized larger than estimated PCR, has no safety-significance for CANDU reactor design. Since the CANDU 6 PCR is small, variations in the range of values for PCR on the performance or safety of the reactor are not significant.

  9. The predictable nature of the Paleozoic sedimentary sequence beneath the Bruce nuclear site in Southern Ontario, Canada

    International Nuclear Information System (INIS)

    Parmenter, Andrew; Jensen, Mark; Crowe, Richard

    2012-01-01

    Document available in extended abstract form only. A key aspect of a Deep Geologic Repository (DGR) safety case is the ability to develop and communicate an understanding of the geologic stability and resilience to change at time frames relevant to demonstrating repository performance. As part of an on-going Environmental Assessment, Ontario Power Generation (OPG) recently completed site-specific investigations within an 850 m thick Paleozoic sedimentary sequence beneath the Bruce nuclear site for the proposed development of a DGR for Low and Intermediate Level Waste (L and ILW). As envisioned, the shaft-accessed DGR would be excavated at a nominal depth of 680 m within the low permeability Ordovician argillaceous limestone of the Cobourg Formation, which is overlain by more than 200 m of low permeability Ordovician shale. The geo-scientific investigations revealed a relatively undeformed and laterally continuous architecture within the sedimentary sequence at the repository scale (1.5 km 2 ) and beyond. This paper explores the predictable nature of the sedimentary sequence that has contributed to increasing confidence in an understanding of the spatial distribution of groundwater system properties, deep groundwater system evolution and natural barrier performance. Multi-disciplinary geo-scientific investigations of the Bruce nuclear site were completed in 3 phases between 2006 and 2010. The sub-surface investigations included a deep drilling, coring and in-situ testing program and, the completion of a 19.7 km (9 lines) 2-D seismic reflection survey. The drilling program involved 6 (150 mm dia.) deep boreholes (4-vertical; 2 inclined) that were extended through the sedimentary sequence from 4 drill sites, arranged around the 0.3 km 2 footprint of the proposed repository. The more than 3.8 km of rock core (77 mm dia.) retrieved have provided, in part, a strong basis to understand bedrock lithology and mineralogy, facies assemblages, structure, and oil and gas

  10. Plutonium Consumption Program, CANDU Reactor Project final report

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-31

    DOE is investigating methods for long term dispositioning of weapons grade plutonium. One such method would be to utilize the plutonium in Mixed OXide (MOX) fuel assemblies in existing CANDU reactors. CANDU (Canadian Deuterium Uranium) reactors are designed, licensed, built, and supported by Atomic Energy of Canada Limited (AECL), and currently use natural uranium oxide as fuel. The MOX spent fuel assemblies removed from the reactor would be similar to the spent fuel currently produced using natural uranium fuel, thus rendering the plutonium as unattractive as that in the stockpiles of commercial spent fuel. This report presents the results of a study sponsored by the DOE for dispositioning the plutonium using CANDU technology. Ontario Hydro`s Bruce A was used as reference. The fuel design study defined the optimum parameters to disposition 50 tons of Pu in 25 years (or 100 tons). Two alternate fuel designs were studied. Safeguards, security, environment, safety, health, economics, etc. were considered. Options for complete destruction of the Pu were also studied briefly; CANDU has a superior ability for this. Alternative deployment options were explored and the potential impact on Pu dispositioning in the former Soviet Union was studied. An integrated system can be ready to begin Pu consumption in 4 years, with no changes required to the reactors other than for safe, secure storage of new fuel.

  11. Plutonium Consumption Program, CANDU Reactor Project final report

    International Nuclear Information System (INIS)

    1994-01-01

    DOE is investigating methods for long term dispositioning of weapons grade plutonium. One such method would be to utilize the plutonium in Mixed OXide (MOX) fuel assemblies in existing CANDU reactors. CANDU (Canadian Deuterium Uranium) reactors are designed, licensed, built, and supported by Atomic Energy of Canada Limited (AECL), and currently use natural uranium oxide as fuel. The MOX spent fuel assemblies removed from the reactor would be similar to the spent fuel currently produced using natural uranium fuel, thus rendering the plutonium as unattractive as that in the stockpiles of commercial spent fuel. This report presents the results of a study sponsored by the DOE for dispositioning the plutonium using CANDU technology. Ontario Hydro's Bruce A was used as reference. The fuel design study defined the optimum parameters to disposition 50 tons of Pu in 25 years (or 100 tons). Two alternate fuel designs were studied. Safeguards, security, environment, safety, health, economics, etc. were considered. Options for complete destruction of the Pu were also studied briefly; CANDU has a superior ability for this. Alternative deployment options were explored and the potential impact on Pu dispositioning in the former Soviet Union was studied. An integrated system can be ready to begin Pu consumption in 4 years, with no changes required to the reactors other than for safe, secure storage of new fuel

  12. Two new species of the stenopodidean shrimp genus Spongiocaris Bruce & Baba, 1973 (Crustacea: Decapoda: Spongicolidae) from the Indo-West Pacific.

    Science.gov (United States)

    Komai, Tomoyuki; Grave, Sammy De; Saito, Tomomi

    2016-05-17

    Two new species of the deep-water spongicolid genus Spongiocaris Bruce & Baba, 1973, are described and illustrated from two localities in the Indo-West Pacific. Spongiocaris panglao n. sp. is described on the basis of material from the Bohol Sea, the Philippines, at depths of 220-731 m. Spongiocaris tuerkayi n. sp. is described on the basis of material from Atlantis Bank in the southwestern Indian Ocean at depths of 743-1053 m. Among eight known congeners, both new species appear close to S. semiteres Bruce & Baba, 1973, differing in the rostral length and armature, shape of the carapace, telsonal armature, development of the grooming apparatus of the first pereopod and shape of the third pereopod chela. An identification key to the species currently assigned to Spongiocaris is presented.

  13. Restoration to serviceability of Bruce 'A' heat transfer equipment

    International Nuclear Information System (INIS)

    Gammage, D.; Machowski, C.; McGillivray, R.; Durance, D.; Kazimer, D.; Werner, K.

    2009-01-01

    Bruce Units 1 to 4 were shut down during the 1990s by the former Ontario Hydro, due in part to a long list of system and equipment deficiencies and concerns, including steam generator tube degradation as a consequence of the then-existing steam generator secondary side water chemistry conditions. Upon its creation in 2001, and following a program of condition assessment, Bruce Power was able to determine that Units 3 and 4 could return to service; but that Units 1 and 2 would require refurbishment. That Refurbishment Program, which is currently well advanced, included the re-assessment of the condition of equipment throughout the plant including the heat transfer equipment; and determination item-by-item as to what inspection, cleaning, repair, or even replacement would be required to put the equipment into a condition where it could be expected to operate reliably for the additional 30 years expected from the plant. Clearly the objective is to suitably restore the equipment to serviceability without doing more refurbishment work than is warranted - without replacing equipment except where absolutely necessary. The first task in such a program is determination of its scope - i.e. a listing of all heat exchangers. That list included everything from the steam generators (which required replacement, now completed), to much smaller heat exchangers in the heavy water upgrader systems (which were found to be in very good overall condition). There is also a very large number of other so-called 'balance-of-plant' heat exchangers; these include the maintenance coolers, moderator heat exchangers, shutdown coolers and a whole raft of smaller coolers - many of which are cooled directly by lake water with its potential for bio-fouling and 'BIC' (Biologically Induced Corrosion). This paper focuses primarily on the engineering assessment, inspection, repair and general refurbishment of the balance-of-plant heat exchangers. As will be discussed in the paper, the assessment of the

  14. Annual report/1979

    International Nuclear Information System (INIS)

    1980-04-01

    Primary energy demand in Ontario in 1979 was up by 2.9 percent, compared to 2.7 percent in the previous year. Revised forecasts issued in January 1980 indicate Ontario's need for electricity is expected to grow by an average of 3.4 percent annually to the year 2000. Nuclear generation provided 29 percent of the total energy made available by Hydro, and Hydro's eight reactors at Pickering and Bruce continued to rank in the top 36 - four in the top 10 - when compared to the permance of 104 of the world's largest reactors. The provinical legislature's Select Committee on Hydro Affairs examined the safety of the CANDU system and concluded that is is 'acceptably safe'. Faced with reduced forecasts of electrical demands to the year 2000 the Board of Directors decided to stretch out the construction schedule of the Darlington station, to halt construction of the second half of the Bruce Heavy Water Plant D, and to complete but mothball the first half. Construction of Bruce Heavy Water Plant B was completed early in 1979. The A plant produced 599.8 megagrams of reactor-grade heavy water. A control room simulator for Bruce A nuclear generating station was ordered. Agreement was reached on rebuilding faulty boilers at Pickering B. A total of 757.6 megagrams of uranium was used to produce electrical energy and steam. Ontario Hydro continued involvement in uranium exploration. Studies on radioactive waste disposal are being carried out, with emphasis on interim storage and transportation. (LL)

  15. Prediction of hydrogen distribution in the reactor building in CANDU6 plant

    International Nuclear Information System (INIS)

    Jin, Y.; Song, Y.

    2008-01-01

    The CANDU plants have a lot of zircaloy. The fuel cladding, calandria tubes and pressure tubes are made of zircaloy. The zircaloy can be oxidized and hydrogen is generated during severe accident progression. The detonation or deflagration to detonation transition (DDT) due to hydrogen combustion may occur if the local hydrogen concentration or global hydrogen concentration exceeds certain value. The detonation may result in the rupture of the reactor building. The inside of the reactor building of CANDU plants is complex. So prediction of hydrogen distribution in the reactor building is important. This prediction is made using ISAAC code and GOTHIC code. ISAAC code partitioned the reactor building in to 7 compartments. GOTHIC code modeled the CANDU6 reactor building using 12 nodes. The hydrogen concentrations in the various compartments in the reactor building are compared. GOTHIC code slightly underpredicts hydrogen concentration in the F/M rooms than ISAAC code, but trend is same. The hydrogen concentration in the boiler room and the moderator room shows almost same as for both codes. (author)

  16. Evaluation of a pilot fish handling system at Bruce NGS 'A'

    International Nuclear Information System (INIS)

    Griffiths, J.S.

    1985-10-01

    A pilot fish recovery system using a Hidrostal fish pump was tested in the Bruce NGS 'A' forebay during June, 1984. Despite low forebay fish concentrations, the system was capable of capturing 97,000 alewife/day (3900 kg) if operated continuously. Post-pumping survival averaged 97%. It is estimated that a single pump could handle alewife runs in the 40,000 to 70,000 kg range, but multiple pumps or a single larger pump would be required to assure station protection from the largest runs (>100,000 kg). Results indicate that tank/trailer return of pumped fish is feasible, but other alternatives for returning fish to Lake Huron are also being considered

  17. 1200 FPD refuelling simulation of RUFIC fuel in a CANDU 6 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soon Young; Jeong, Chang Joon; Min, Byung Joo; Suk, Ho Chun

    2001-07-01

    The refuelling strategy of RUFIC (Recovered Uranium Fuel in CANDU) fuel as a high-burnup fuel for a CANDU 6 reactor is studied to determine the achievable operation characteristics of the fuel and reactor. In this study, three refuelling schemes of 4-, 2-, and 3-bundle shift for 0.92 w/o RUFIC fuel in an CANDU 6 reactor were individually evaluated through 1200 FPD(Full Power Day)refuelling simulaltions where the 0.92 w/o RUFIC is equivalent to CANFLEX 0.9 w/o SEU(Slightly Enriched Uranium) in reactivity and burnup respects. The computer code system used for this study is WIMS-AECL/DRAGON/RFSP. The results simulated for the case of 4-bundle shift refueling scheme shows that the peak maximum channel power and peak maximum CPPF(Channel Power Peaking Factor)of 7228 kW and 1.175, respectively, seems too high to maintain the available operating margins, because some data of the maximum channel power exceed the operating limit(7070 kW based on the Technical Specifications of Wolsong 3 and 4 Units). Whereas, the results simulated for the case of 2-bundle shift refuelling scheme shows that sufficient operating margin could be secured where the peak maximum channel power and peak maximum CPPF were 6889 kW and 1.094, respectively. However, the channel refuelling rate (channels/day) of the 2-bundle shift refuelling scheme is twice that of the 4-bundle shift refuelling scheme, and hence the 2-bundle shift refuelling would not be an economical refuelling scheme for the RUFIC fuel bundles. Therefore, a 3-bundle shift refuelling scheme for the RUFIC fuel in CANDU 6 reactor was also studied by the 1200 FPD refuelling simulation. As a result, it is found that all the operating parameters in the 3-bundle shift case are achivable for the CANDU 6 reactor operation, and the channel refuelling rate of 2.88 channels/day seems to be attractive compared to the refuelling rate of 4.32 channels/day in the 2-bundle shift case.

  18. UF6 breeder reactor power plants for electric power generation

    International Nuclear Information System (INIS)

    Rust, J.H.; Clement, J.D.; Hohl, F.

    1976-01-01

    The reactor concept analyzed is a 233 UF 6 core surrounded by a molten salt (Li 7 F, BeF 2 , ThF 4 ) blanket. Nuclear survey calculations were carried out for both spherical and cylindrical geometries. A maximum breeding ratio of 1.22 was found. Thermodynamic cycle calculations were performed for a variety of Rankine cycles. Optimization of a Rankine cycle for a gas core breeder reactor employing an intermediate heat exchanger gave a maximum efficiency of 37 percent. A conceptual design is presented along with a system layout for a 1000 MW stationary power plant. The advantages of the GCBR are as follows: (1) high efficiency, (2) simplified on-line reprocessing, (3) inherent safety considerations, (4) high breeding ratio, (5) possibility of burning all or most of the long-lived nuclear waste actinides, and (6) possibility of extrapolating the technology to higher temperatures and MHD direct conversion

  19. Optimization of the neutron calculation model for the RA-6 reactor

    International Nuclear Information System (INIS)

    Coscia, G.A.

    1981-01-01

    A model for the neutronic calculation of the RA-6 reactor which includes the codes ANISN and EQUIPOSE is analyzed. Starting with a brief description of the reactor, the core and its parts, the general scheme of calculation applied is presented. The fuel elements used were those which are utilized in the RA-3 reactor; this is of the MTR type with 90% enriched uranium. With the approximations used, an analysis of such model of calculation was made, trying to optimize it by reducing, if possible, the calculation time without loosing accuracy. In order to improve the calculation model, it is recomended a cross section data library specific for the enrichment of the fuel considered 90% and the incorporation of a more advanced code than EQUIPOISE which would be DIXYBAR. (M.E.L.) [es

  20. AECB staff annual assessment of the Bruce Heavy Water Plant for the year 1994

    International Nuclear Information System (INIS)

    1995-06-01

    This report is the Atomic Energy Control Board staff assessment of the operation of Bruce Heavy Water Plant (BHWP) during 1994. BHWP operation was acceptably safe in 1994. At BHWP, Ontario Hydro did not breach any of the regulations issued under the authority of the Atomic Energy Control Act. There were four minor violations of the BHWP Operating Licence. In all cases, Ontario Hydro exceeded Ontario Hydro government limits for releases to the environment. None of the events threatened public health or the environment. 2 figs

  1. Materials considerations for UF6 gas-core reactor. Interim report for preliminary design study

    International Nuclear Information System (INIS)

    Wagner, P.

    1977-04-01

    The limiting materials problem in a high-temperature UF 6 core reactor is the corrosion of the core containment vessel. The UF 6 , the lower fluorides of uranium, and the fluorine that exist at the anticipated reactor operating conditions (1000 K and about one atmosphere UF 6 ) are all corrosive. Because of this, the materials evaluation effort for this reactor design study has concentrated on the identification of a viable system for the containment vessel that meets both the materials and neutronic requirements. A study of the literature has revealed that the most promising corrosion-resistant candidates are Ni or Ni-Al alloys. One of the conclusions of this work is that the containment vessel use a nickel liner or clad since the use of Ni as a structural member is precluded by its relative blackness to thermal neutrons. Estimates of corrosion rates of Ni and Ni-Al alloys, the effects of the pressure and temperature of F 2 on the corrosion rates, calculated equilibrium gas compositions at reactor core operating conditions, suggested methods of fabrication, and recommendations for future research and development are included

  2. Analysis of effects of calandria tube uncovery under severe accident conditions in CANDU reactors

    International Nuclear Information System (INIS)

    Rogers, J.T.; Currie, T.C.; Atkinson, J.C.; Dick, R.

    1983-01-01

    A study is being undertaken for the Atomic Energy Control Board to assess the thermal and hydraulic behaviour of CANDU reactor cores under accident conditions more severe than those normally considered in the licensing process. In this paper, we consider the effects on a coolant channel of the uncovery of a calandria tube by moderator boil-off following a LOCA in a Bruce reactor unit in which emergency cooling is ineffective and the moderator heat sink is impaired by the failure of the moderator cooling system. Calandria tube uncovery and its immediate consequences, as described here, constitute only one part of the entire accident sequence. Other aspects of this sequence as well as results of the analysis of the other accident sequences studied will be described in the final report on the project and in later papers

  3. Control maintenance training program for special safety systems at Bruce B

    International Nuclear Information System (INIS)

    Reinwald, G.

    1997-01-01

    It was recognized from the early days of commissioning of Bruce B that Control Maintenance staff would require a level of expertise to be able to maintain Special Safety Systems in proper running order. In the early 80's this was achieved through hands on experience during the original commissioning, troubleshooting and placing of the various systems in service. Control maintenance procedures were developed and implemented as the new systems came available for commissioning, as were operating manuals,training manuals etc. Under the development of the Maintenance Manager, a Conduct of Maintenance section was organized. One of the responsibilities of this section was to develop a series of Maintenance Administrative Procedures (MAPs) that set the standards for maintenance activities including training

  4. Enhanced CANDU6: Reactor and fuel cycle options - Natural uranium and beyond

    International Nuclear Information System (INIS)

    Ovanes, M.; Chan, P. S. W.; Mao, J.; Alderson, N.; Hopwood, J. M.

    2012-01-01

    The Enhanced CANDU 6 R (ECo R ) is the updated version of the well established CANDU 6 family of units incorporating improved safety characteristics designed to meet or exceed Generation III nuclear power plant expectations. The EC6 retains the excellent neutron economy and fuel cycle flexibility that are inherent in the CANDU reactor design. The reference design is based on natural uranium fuel, but the EC6 is also able to utilize additional fuel options, including the use of Recovered Uranium (RU) and Thorium based fuels, without requiring major hardware upgrades to the existing control and safety systems. This paper outlines the major changes in the EC6 core design from the existing C6 design that significantly enhance the safety characteristics and operating efficiency of the reactor. The use of RU fuel as a transparent replacement fuel for the standard 37-el NU fuel, and several RU based advanced fuel designs that give significant improvements in fuel burnup and inherent safety characteristics are also discussed in the paper. In addition, the suitability of the EC6 to use MOX and related Pu-based fuels will also be discussed. (authors)

  5. AECB staff annual assessment of the Bruce Heavy Water Plant for the year 1995

    International Nuclear Information System (INIS)

    1996-06-01

    The Atomic Energy Control Board's staff annual assessment of the operation of Bruce Heavy Water Plant (BHWP) during 1995. BHWP operation was acceptably safe in 1995. At BHWP, Ontario Hydro complied with the regulations issued under the authority of the Atomic Energy Control Act. AECB is satisfied that BHWP did not pose any undue risk to public health or safety or to the environment. Ontario Hydro met all safety system and safety related system availability targets at BHWP in 1995. The emergency response capability is satisfactory. 2 figs

  6. NF-6 program complex for BESM-6 computation of the basic neutron-physical characteristics of nuclear reactors

    International Nuclear Information System (INIS)

    Zizin, M.N.; Savochkina, O.A.; Chukhlova, O.P.

    1978-01-01

    A structure of standard designations is described and semantics of a number of standard values used in a NF-6 program complex is given. Main source data and results of neutron-physical reactor calculation are standard values, the peculiarities of FORTRAN and ALGOL-GDR algorithm languages in the DUBNA monitoring system were taken account of. As a base of standard values list the FIHAR system list, supplemented with new standard designations for integral reactor characteristics, is used. Developed is also a list of standard values to organize the exchange with external memory in the process of task solution and long-range storage

  7. Fast reactors and problems in their development. Chapter 6

    International Nuclear Information System (INIS)

    Dombey, N.

    1980-01-01

    The main differences between fast reactors, in particular the liquid-metal fast breeder reactor (LMFBR), and thermal reactors are discussed. The view is taken, based on the intrinsic physics of the systems, that fast reactors should be considered as a different genus from thermal reactors. Some conclusions are drawn for fast reactor development generally and for the British programme in particular. Physics, economics and safety aspects are covered. (U.K.)

  8. Implementation of a reactivity meter for the RA-6 reactor

    International Nuclear Information System (INIS)

    Herzovich, P.F.

    1991-06-01

    An 'on line' and 'off line' digital reactivity meter was developed and implemented for the RA-6 research reactor. Safety and control rod calibration will be permitted by means of this system with the same precision and faster than the period method, becoming a helpful tool to the operator in critical approach and in experimental design. (Author) [es

  9. Wireless condition monitoring for the RA-6 research reactor

    International Nuclear Information System (INIS)

    Garcia Peyrano, O.; Calzeta, O.; Rico, N.; Damiani, H.; Coutsiers, E.

    1999-01-01

    The vibration laboratory at C.A.B. has a great experience with the analysis and diagnostic of symptoms of failures in the rotating equipment of the R-6 research reactor and in our longest NPP (CANDU 600 Mw), located in Embalse town, Cordoba City, Argentina. Objective: The standard condition monitoring instrumentation system were designed for large equipment operating under different environmental conditions and sensitivities. The signal processing is not flexible and the diagnostic is an expensive method for the small poll type research reactors. This papers describes the research and development which are related whit the new concept, cheaper and flexible condition monitoring instrumentation system. Implementing a vibration analysis measurements technique with a sensor inside (in the pool) of the nuclear reactor RA-6, and mainly based on fft signal processing, an extensive program for vibration source identification was done. Different nuclear power conditions were monitored as full power and in zero power, also. This zero power shows the best acoustical environmental, because the cooling pumps are stop, and the core is cooling by natural convection. Two sensors were mainly used as the detector's subsystem. One of these detectors was an accelerometer attached to the top of the fine control rod and the other one was a water resistant omnidirectional microphone which was located underwater at different distances from the nuclear core. All the signal measurement by this two sensors were recorded and then was processed. Both signal was acquired at the same time for correlation analysis purposes. The analysis was composed by a 'Spectral Dynamics SD380' connected to a P.C. with dedicated post processing software. On the other hand, some calibration and sensitivity comparison was done using an SKFCM40, dual channel data collector and analyzer. (author)

  10. Measurement of fast neutron spectra inside reactors with a Li{sup 6} semiconductor counter spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Ajdacic, V S; Lalovic, B I; Petrovic, B P [Institute of nuclear sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1963-12-15

    The possibility of using the Li{sup 6} semiconductor counter spectrometer for measuring fast neutron spectra inside reactors has been investigated in details and some solutions of the difficulties associated with the high interference of thermal neutrons in well-moderated reactors are suggested and checked experimentally (author)

  11. A compact, low cost, tritium removal plant for CANDU-6 reactors

    International Nuclear Information System (INIS)

    Sood, S.K.; Fong, C.; Kalyanam; Woodall, K.B.

    1997-01-01

    Tritium concentrations in CANDU-6 reactors are currently around 40 Ci/kg in moderator systems and around 1.5 Ci/kg in primary heat transport (PHT) systems. It is expected that tritium concentrations in moderator systems will continue to rise and will reach about 80 Ci/kg at maturity. A more detailed description of the increase in tritium concentrations in the moderator and PHT systems of CANDU-6 reactors is given in the next section of this paper. While moderator systems currently contribute more than 50% to tritium emissions, the impact of acute releases of moderator water is more severe at higher tritium concentrations. This impact can be substantially reduced by the addition of an isotope separation system for lowering the tritium level in the moderator system. In addition, lower tritium levels in CANDU systems will inevitably result in reduced occupational exposures, or will provide economic benefits due to ease of maintenance because less protective measures are required and maintenance activities can be more efficient

  12. SORO post-simulations of Bruce A Unit 4 in-core flux detector verification tests

    Energy Technology Data Exchange (ETDEWEB)

    Braverman, E.; Nainer, O. [Bruce Power, Nuclear Safety Analysis and Support Dept., Toronto, Ontario (Canada)]. E-mail: Evgeny.Braverman@brucepower.com; Ovidiu.Nainer@brucepower.com

    2004-07-01

    During the plant equipment assessment prior to requesting approval for restart of Bruce A Units 3 and 4 it was determined that all in-core flux detectors needed to be replaced. Flux detector verification tests were performed to confirm that the newly installed detectors had been positioned according to design specifications and that their response closely follows the calculated flux shape changes caused by selected reactivity mechanism movements. By comparing the measured and post-simulated RRS and NOP detector responses to various perturbations, it was confirmed that the new detectors are wired and positioned correctly. (author)

  13. Biodegradation of p-nitrophenol using Arthrobacter chlorophenolicus A6 in a novel upflow packed bed reactor

    International Nuclear Information System (INIS)

    Sahoo, Naresh Kumar; Pakshirajan, Kannan; Ghosh, Pranab Kumar

    2011-01-01

    A novel packed bed reactor (PBR) was designed with cross flow aeration at multiple ports along the depth to improve the hydrodynamic conditions of the reactor, and the biodegradation efficiency of Arthrobacter chlorophenolicus A6 on p-nitrophenol (PNP) removal in PBR at different PNP loading rates were evaluated. The novel PBR was designed to improve the hydrodynamic features such as mixing time profile (t m95 ), oxygen mass transfer coefficient (k L a), and overall gas hold up capacity (ε G ) of the reactor. PNP concentration in the influent was varied between 600 and 1400 mg l -1 whereas the hydraulic retention time (HRT) in the reactor was varied between 18 and 7.5 h. Complete removal of PNP was achieved in the reactor up to a PNP loading rate of 2787 mg l -1 d -1 . More than 99.9% removal of PNP was achieved in the reactor for an influent concentration of 1400 mg l -1 and at 18 h HRT. In the present study, PNP was utilized as sole source of carbon and energy by A. chlorophenolicus A6. Furthermore, the bioreactor showed good compatibility in handling shock loading of PNP.

  14. Analogue to digital upgrade project-boiler feedwater control system for Bruce Power nuclear units 1 & 2

    International Nuclear Information System (INIS)

    Long, R.

    2012-01-01

    Bruce Power Nuclear Generating Station A, “Bruce A” is in the final stages of its Restart Project. This capital project will see a large scale rehabilitation of Units 1 and 2 resulting in addition of 1500MW of safe, reliable, clean electricity to the Ontario grid. Restart Project Scope 375, Boiler Feedwater Controls Upgrade was sanctioned to replace obsolete analog devices with a modern digital control system. This project replaced the existing Foxboro H Line analog controls which comprised of 81 individual control modules and support instrumentation. The replacement system was a Triconex Triple Modular Redundant PLC which interfaces with two redundant touch screen monitors. The upgraded digital system incorporates the following controls: 1. Boiler Level Control Loops 2. Dearator Level Control Loops 3. Dearator Pressure Control Loops 4. Boiler Feedwater Recirculation Flow Control Loops A number of technical challenges were addressed when installing a new digital system within the existing plant configuration. Interfaces to new, old and refurbished field devices must be understood as well as implications of connecting to the plant’s Digital Control Computers (DCC’s) and newly installed Steam Generators. The overall project involved many stakeholders to address various requirements from conceptual / design stage through procurement, construction, commissioning and return to service. In addition, the project highlighted the unique requirements found in Nuclear Industry with respect to Human Factors and Software Quality Assurance. (author)

  15. SoLid: Search for Oscillations with Lithium-6 Detector at the SCK-CEN BR2 reactor

    Science.gov (United States)

    Ban, G.; Beaumont, W.; Buhour, J. M.; Coupé, B.; Cucoanes, A. S.; D'Hondt, J.; Durand, D.; Fallot, M.; Fresneau, S.; Giot, L.; Guillon, B.; Guilloux, G.; Janssen, X.; Kalcheva, S.; Koonen, E.; Labare, M.; Moortgat, C.; Pronost, G.; Raes, L.; Ryckbosch, D.; Ryder, N.; Shitov, Y.; Vacheret, A.; Van Mulders, P.; Van Remortel, N.; Weber, A.; Yermia, F.

    2016-04-01

    Sterile neutrinos have been considered as a possible explanation for the recent reactor and Gallium anomalies arising from reanalysis of reactor flux and calibration data of previous neutrino experiments. A way to test this hypothesis is to look for distortions of the anti-neutrino energy caused by oscillation from active to sterile neutrino at close stand-off (˜ 6- 8m) of a compact reactor core. Due to the low rate of anti-neutrino interactions the main challenge in such measurement is to control the high level of gamma rays and neutron background. The SoLid experiment is a proposal to search for active-to-sterile anti-neutrino oscillation at very short baseline of the SCK•CEN BR2 research reactor. This experiment uses a novel approach to detect anti-neutrino with a highly segmented detector based on Lithium-6. With the combination of high granularity, high neutron-gamma discrimination using 6LiF:ZnS(Ag) and precise localization of the Inverse Beta Decay products, a better experimental sensitivity can be achieved compared to other state-of-the-art technology. This compact system requires minimum passive shielding allowing for very close stand off to the reactor. The experimental set up of the SoLid experiment and the BR2 reactor will be presented. The new principle of neutrino detection and the detector design with expected performance will be described. The expected sensitivity to new oscillations of the SoLid detector as well as the first measurements made with the 8 kg prototype detector deployed at the BR2 reactor in 2013-2014 will be reported.

  16. CANDU 6 - the highly successful medium sized reactor

    International Nuclear Information System (INIS)

    Hedges, K. R.; Allen, P. J.; Hopwood, J. M.

    2000-01-01

    The CANDU 6 Pressurized Heavy Water Reactor system, featuring horizontal fuel channels and heavy water moderator continues to evolve, supported by AECL's strong commitment to comprehensive R and D programs. The initial CANDU 6 design started in the 1970's. The first plants went into service in 1983, and the latest version of the plant is under construction in China. With each plant the technology has evolved giving the dual advantages of proveness and modern technology. CANDU 6 delivers important advantages of the CANDU system with benefit to small and medium-sized grids. This technology has been successfully adopted by, and localized to varying extents in, each of the CANDU 6 markets. For example, all CANDU owners obtain their fuel from domestic suppliers. Progressive CANDU development continues at AECL to enhance this medium size product CANDU 6. There are three key CANDU development strategic thrusts: improved economics, fuel cycle flexibility, and enhanced safety. The CANDU 6 product is also enhanced by incorporating improvements and advanced features that will be arising from our CANDU Technology R and D programs in areas such as heavy water and tritium, control and instrumentation, fuel and fuel cycles, systems and equipment and safety and constructability. (author)

  17. Bruce's Magnificent Quartet: Inquiry, Community, Technology and Literacy--Implications for Renewing Qualitative Research in the Twenty-First Century

    Science.gov (United States)

    Davidson, Judith

    2014-01-01

    Bruce and Bishop's community informatics work brings forward four critical concepts: inquiry, community, technology, and literacy. These four terms serve as the basis for a discussion of qualitative research in the twenty-first century--what is lacking and what is needed. The author suggests that to resolve the tensions or challenges…

  18. The supply of steam from Candu reactors for heavy water production

    International Nuclear Information System (INIS)

    Robertson, R.F.S.

    1975-09-01

    By 1980, Canada's energy needs for D 2 O production will be 420 MW of electrical energy and 3600 MW of thermal energy (as steam). The nature of the process demands that this energy supply be exceptionally stable. Today, production plants are located at or close to nuclear electricity generating sites where advantage can be taken of the low cost of both the electricity and steam produced by nuclear reactors. Reliability of energy supply is achieved by dividing the load between the multiple units which comprise the sites. The present and proposed means of energy supply to the production sites at the Bruce Heavy Water Plant in Ontario and the La Prade Heavy Water Plant in Quebec are described. (author)

  19. Chemical cleaning of the Bruce A steam generators

    International Nuclear Information System (INIS)

    Le Surf, J.E.; Mason, J.B.; Symmons, W.R.; Yee, F.

    1992-01-01

    Deposits consisting mostly of oxides and salts and copper metal in the secondary side of the steam generators at the Bruce A Nuclear Generating Station have caused instability in the steam flow and loss of heat capacity, resulting in derating of the units and reduction in power production. Attempts to remove the deposits by pressure pulsing were unsuccessful. Water lancing succeeded in restoring stability, but restrictions on access prevented complete lancing of the tube support plate holes. Chemical cleaning using a modified EPRI-SGOG process has been selected as the best method of removing the deposits. A complete chemical cleaning system has been designed and fabricated for Ontario Hydro by Pacific Nuclear, with support from AECL CANDU and their suppliers. The system consists of self contained modules which are easily interconnected on site. The whole process is controlled from the Control Module, where all parameters are monitored on a computer video screen. The operator can control motorized valves, pumps and heaters from the computer key board. This system incorporates all the advanced technologies and design features that have been developed by Pacific Nuclear in the design, fabrication and operation of many systems for chemical decontamination and cleaning of nuclear systems. 2 figs

  20. Improvement of top shield analysis technology for CANDU 6 reactor

    International Nuclear Information System (INIS)

    Kim, Kyo Yoon; Jin, Young Kwon; Lee, Sung Hee; Moon, Bok Ja; Kim, Yong Il

    1996-07-01

    As for Wolsung NPP unit 1, radiation shielding analysis was performed by using neutron diffusion codes, one-dimensional discrete ordinates code ANISN, and analytical methods. But for Wolsung NPP unit 2, 3, and 4, two-dimensional discrete ordinates code DOT substituted for neutron diffusion codes. In other words, the method of analysis and computer codes used for radiation shielding of CANDU 6 type reactor have been improved. Recently Monte Carlo MCNP code has been widely utilized in the field of radiation physics and other radiation related areas because it can describe an object sophisticately by use of three-dimensional modelling and can adopt continuous energy cross-section library. Nowadays Monte Carlo method has been reported to be competitive to discrete ordinate method in the field of radiation shielding and the former has been known to be superior to the latter for complex geometry problem. However, Monte Carlo method had not been used for radiation streaming calculation in the shielding design of CANDU type reactor. Neutron and gamma radiations are expected to be streamed from calandria through the penetrations to reactivity mechanism deck (R/M deck) because many reactivity control units which are established on R/M deck extend from R/M deck to calandria within penetrations, which are provided by guide tube extensions. More precise estimation of radiation streaming is required because R/M deck is classified as an accessible area where atomic worker can access when necessary. Therefore neutron and gamma dose rates were estimated using MCNP code on the R/M deck in the top shield system of CANDU 6 reactor. 9 tabs., 17 figs., 21 refs. (Author)

  1. 75 FR 3217 - J&T Hydro Company; H. Dean Brooks and W. Bruce Cox; Notice of Application for Transfer of License...

    Science.gov (United States)

    2010-01-20

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 11392-009] J&T Hydro Company; H. Dean Brooks and W. Bruce Cox; Notice of Application for Transfer of License and Soliciting Comments and Motions To Intervene January 12, 2010. On October 30, 2009, J&T Hydro Company (transferor) and...

  2. AECB staff annual report of Bruce B NGS for the year 1991

    International Nuclear Information System (INIS)

    1992-11-01

    In this account of Bruce NGS B station operation during the year 1991 AECB staff have pointed out non-compliances with the operating licence, which have been few in number and minor in degree of seriousness. There were no exposures of workers to radiation in excess of regulatory limits, but there were contraventions of the ALARA principle. Releases of radioactive material to the environment have been well below the target levels. The performance of the four special safety systems has been good, except for the containment system. A review of the significant event reports and the causes of the events has revealed a lack of a system by which operations and maintenance work could be verified to have been carried out as intended. In operations and maintenance the backlog of work to be done to regularize temporary changes to equipment (removal of jumpers), to carry out preventive maintenance (call-ups), and to make repairs (deficiency reports) has increased from that of the previous year. On the other hand, the station has reduced the number of temporary operating instructions (operating memos) to half of what it was last year. The fretting of steam generator tubes reported last year has not become worse. Nevertheless, inspections continue and modifications to the tube supports are underway. Overall plant chemistry has been acceptable. An Ontario Hydro assessment of the station found the station management's expectations for maintaining the margin of safety in the plant had not been properly communicated to all levels of station staff. The station is now attempting to correct this. Infractions of work protection procedures, which were the subject of many significant events, have led to changes in the procedures and resulted in a major training effort. AECB staff believe that Ontario Hydro has continued to operate Bruce NGS B in a safe manner, but have pointed out areas where improvement is required. (Author)

  3. Biodegradation of p-nitrophenol using Arthrobacter chlorophenolicus A6 in a novel upflow packed bed reactor.

    Science.gov (United States)

    Sahoo, Naresh Kumar; Pakshirajan, Kannan; Ghosh, Pranab Kumar

    2011-06-15

    A novel packed bed reactor (PBR) was designed with cross flow aeration at multiple ports along the depth to improve the hydrodynamic conditions of the reactor, and the biodegradation efficiency of Arthrobacter chlorophenolicus A6 on p-nitrophenol (PNP) removal in PBR at different PNP loading rates were evaluated. The novel PBR was designed to improve the hydrodynamic features such as mixing time profile (t(m95)), oxygen mass transfer coefficient (k(L)a), and overall gas hold up capacity (ɛ(G)) of the reactor. PNP concentration in the influent was varied between 600 and 1400 mg l(-1) whereas the hydraulic retention time (HRT) in the reactor was varied between 18 and 7.5h. Complete removal of PNP was achieved in the reactor up to a PNP loading rate of 2787 mg l(-1)d(-1). More than 99.9% removal of PNP was achieved in the reactor for an influent concentration of 1400 mg l(-1) and at 18 h HRT. In the present study, PNP was utilized as sole source of carbon and energy by A. chlorophenolicus A6. Furthermore, the bioreactor showed good compatibility in handling shock loading of PNP. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Containment Loads Analysis for CANDU6 Reactor using CONTAIN 2.0

    International Nuclear Information System (INIS)

    Kim, Tae H.; Yang, Chae Y.

    2013-01-01

    The containment plays an important role to limit the release of radioactive materials to the environment during design basis accidents (DBAs). Therefore, the containment has to maintain its integrity under DBA conditions. Generally, a containment functional DBA evaluation includes calculations of the key containment loads, i. e., pressure and temperature effects associated with a postulated large rupture of the primary or secondary coolant system piping. In this paper, the behavior of containment pressure and temperature was evaluated for loss of coolant accidents (LOCAs) of the Wolsong unit 1 in order to assess the applicability of CONTAIN 2.0 code for the containment loads analysis of the CANDU6 reactor. The containment pressure and temperature of the Wolsong unit 1 were evaluated using the CONTAIN 2.0 code and the results were compared with the CONTEMPT4 code. The peak pressure and temperature calculated by CONTAIN 2.0 agreed well with those of CONTEMPT4 calculation. The overall result of this analysis shows that the CONTAIN 2.0 code can apply to the containment loads analysis for the CANDU6 reactor

  5. Calculation of the radial and axial flux and power distribution for a CANDU 6 reactor with both the MCNP6 and Serpent codes

    International Nuclear Information System (INIS)

    Hussein, M.S.; Bonin, H.W.; Lewis, B.J.

    2014-01-01

    The most recent versions of the Monte Carlo-based probabilistic transport code MCNP6 and the continuous energy reactor physics burnup calculation code Serpent allow for a 3-D geometry calculation accounting for the detailed geometry without unit-cell homogenization. These two codes are used to calculate the axial and radial flux and power distributions for a CANDU6 GENTILLY-2 nuclear reactor core with 37-element fuel bundles. The multiplication factor, actual flux distribution and power density distribution were calculated by using a tally combination for MCNP6 and detector analysis for Serpent. Excellent agreement was found in the calculated flux and power distribution. The Serpent code is most efficient in terms of the computational time. (author)

  6. Calculation of the radial and axial flux and power distribution for a CANDU 6 reactor with both the MCNP6 and Serpent codes

    Energy Technology Data Exchange (ETDEWEB)

    Hussein, M.S.; Bonin, H.W., E-mail: mohamed.hussein@rmc.ca, E-mail: bonin-h@rmc.ca [Royal Military College of Canada, Dept. of Chemistry and Chemical Engineering, Kingston, ON (Canada); Lewis, B.J., E-mail: Brent.Lewis@uoit.ca [Univ. of Ontario Inst. of Tech., Faculty of Energy Systems and Nuclear Science, Oshawa, ON (Canada)

    2014-07-01

    The most recent versions of the Monte Carlo-based probabilistic transport code MCNP6 and the continuous energy reactor physics burnup calculation code Serpent allow for a 3-D geometry calculation accounting for the detailed geometry without unit-cell homogenization. These two codes are used to calculate the axial and radial flux and power distributions for a CANDU6 GENTILLY-2 nuclear reactor core with 37-element fuel bundles. The multiplication factor, actual flux distribution and power density distribution were calculated by using a tally combination for MCNP6 and detector analysis for Serpent. Excellent agreement was found in the calculated flux and power distribution. The Serpent code is most efficient in terms of the computational time. (author)

  7. Thermal gradients caused by the CANDU moderator circulation

    International Nuclear Information System (INIS)

    Mohindra, V.K.; Vartolomei, M.A.; Scharfenberg, R.

    2008-01-01

    The heavy water moderator circulation system of a CANDU reactor, maintains calandria moderator temperature at power-dependent design values. The temperature differentials between the moderator and the cooler heavy water entering the calandria generate thermal gradients in the reflector and moderator. The resultant small changes in thermal neutron population are detected by the out-of-core ion chambers as small, continuous fluctuations of the Log Rate signals. The impact of the thermal gradients on the frequency of the High Log Rate fluctuations and their amplitude is relatively more pronounced for Bruce A as compared to Bruce B reactors. The root cause of the Log Rate fluctuations was investigated using Bruce Power operating plant information data and the results of the investigation support the interpretation based on the thermal gradient phenomenon. (author)

  8. RDT&E Progress and Plansfor Hexavalent Chromium (Cr6+)

    Science.gov (United States)

    2011-05-12

    RDT&E Progress and Plans for Hexavalent Chromium (Cr6+) Bruce Sartwell Weapons Systems and Platforms Program Manager E2S2 Conference May 12, 2011...2011 2. REPORT TYPE 3. DATES COVERED 00-00-2011 to 00-00-2011 4. TITLE AND SUBTITLE RDT&E Progress and Plansfor Hexavalent Chromium (Cr6+) 5a...Development of Accelerated Corrosion Test Protocols Alternatives to Hex Chrome and Cadmium Plating Alternatives to Hex Chrome Pretreatments

  9. Mediador cultural ou antropólogo do mal: Bruce Albert e o caso de “A queda do céu”

    Directory of Open Access Journals (Sweden)

    Karla Alessandra Alves de Souza Ferreira

    2017-07-01

    Full Text Available Este estudo desenvolve uma análise crítica sobre o fragmento “Postscriptum, quando eu é um outro (e vice-versa”, apresentado na obra A Queda do céu: palavras de um xamã yanomami. O livro foi pensado por um xamã yanomami; Davi Kopenawa, e produzido por um etnólogo francês Bruce Albert. Problematizo o processo de produção do livro onde dois universos culturais se encontram, uma produção literária indígena do povo Yanomami que apresenta uma coautoria. Essa análise busca investigar a postura epistêmica de Bruce Albert como mediador cultural ou “antropólogo do mal” no processo de elaboração do livro, a fim de levantar questionamentos sobre o ato tradutório e suas implicações, destacando os desa os e contribuições apresentadas nesse processo. Nesta direção, esse artigo se fundamenta nos pensamentos da história cultural.

  10. Primary Water Chemistry Control during a Planned Outage at Bruce Power

    International Nuclear Information System (INIS)

    Ma, Guoping; Nashiem, Rod; Matheson, Shane; Yabar, Berman; Harper, Bill; Roberts, John G.

    2012-09-01

    Bruce Power has developed a comprehensive outage water chemistry program, which includes both primary and secondary chemistry requirements during planned outages. The purpose of the program is to emphasize the chemistry requirements during outages and subsequent start-ups in order to maintain the integrity of the systems, minimise activity transport and radiation fields, reduce the Carbon-14 release, and to ensure that the requirements are integrated with the outage management program. Prior to a planned outage, Station Chemical Technical Sections identify outage chemistry requirements to Operations and Outage Planning and ensure that work necessary to correct system chemistry issues is within outage work scope. The outage water chemistry program provides direction for establishing alternative sampling locations as demanded by the system configuration during the outage and identifies outage prerequisites for nuclear system purification capabilities. These requirements are contained in an outage checklist. The paper mainly highlights the primary water chemistry issues and chemistry control strategies during planned outages and discusses challenges and successes. (authors)

  11. Water lancing of Bruce-A Unit 3 and 4 steam generators

    International Nuclear Information System (INIS)

    Puzzuoli, F.V.; Murchie, B.; Allen, S.

    1995-01-01

    During the Bruce-A 1993 Unit 4 and 1994 Unit 3 outages, three water lancing operations were carried out along with chemical cleaning as part of the station boiler refurbishment program. The water lancing activities focused on three boiler areas.. 1) support plates to clean partially or completely blocked broach holes and prevent boiler water level oscillations, 2) hot leg U-bend supports (HLUBS) to remove deposits contributing to boiler tube stress corrosion cracking (SCC) and 3) tube sheets to dislodge sludge piles that potentially threaten boiler tube integrity and to flush out post chemical cleaning insoluble residues. The combination of water lancing and chemical cleaning effectively reduced broach hole blockage from up to 100% to 0-10% or less. As a result, boilers in Units 3 and 4 will operate for some time to come without concerns over water level oscillations. However, deposits remained in most tube support plate land areas. (author)

  12. Feasibility Study for Cobalt Bundle Loading to CANDU Reactor Core

    International Nuclear Information System (INIS)

    Park, Donghwan; Kim, Youngae; Kim, Sungmin

    2016-01-01

    CANDU units are generally used to produce cobalt-60 at Bruce and Point Lepreau in Canada and Embalse in Argentina. China has started production of cobalt-60 using its CANDU 6 Qinshan Phase III nuclear power plant in 2009. For cobalt-60 production, the reactor’s full complement of stainless steel adjusters is replaced with neutronically equivalent cobalt-59 adjusters, which are essentially invisible to reactor operation. With its very high neutron flux and optimized fuel burn-up, the CANDU has a very high cobalt-60 production rate in a relatively short time. This makes CANDU an excellent vehicle for bulk cobalt-60 production. Several studies have been performed to produce cobalt-60 using adjuster rod at Wolsong nuclear power plant. This study proposed new concept for producing cobalt-60 and performed the feasibility study. Bundle typed cobalt loading concept is proposed and evaluated the feasibility to fuel management without physics and system design change. The requirement to load cobalt bundle to the core was considered and several channels are nominated. The production of cobalt-60 source is very depend on the flux level and burnup directly. But the neutron absorption characteristic of cobalt bundle is too high, so optimizing design study is needed in the future

  13. Feasibility Study for Cobalt Bundle Loading to CANDU Reactor Core

    Energy Technology Data Exchange (ETDEWEB)

    Park, Donghwan; Kim, Youngae; Kim, Sungmin [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    CANDU units are generally used to produce cobalt-60 at Bruce and Point Lepreau in Canada and Embalse in Argentina. China has started production of cobalt-60 using its CANDU 6 Qinshan Phase III nuclear power plant in 2009. For cobalt-60 production, the reactor’s full complement of stainless steel adjusters is replaced with neutronically equivalent cobalt-59 adjusters, which are essentially invisible to reactor operation. With its very high neutron flux and optimized fuel burn-up, the CANDU has a very high cobalt-60 production rate in a relatively short time. This makes CANDU an excellent vehicle for bulk cobalt-60 production. Several studies have been performed to produce cobalt-60 using adjuster rod at Wolsong nuclear power plant. This study proposed new concept for producing cobalt-60 and performed the feasibility study. Bundle typed cobalt loading concept is proposed and evaluated the feasibility to fuel management without physics and system design change. The requirement to load cobalt bundle to the core was considered and several channels are nominated. The production of cobalt-60 source is very depend on the flux level and burnup directly. But the neutron absorption characteristic of cobalt bundle is too high, so optimizing design study is needed in the future.

  14. Operating reactors licensing actions summary. Vol. 3, No. 6

    International Nuclear Information System (INIS)

    1983-07-01

    The operating reactors licensing actions summary is designed to provide the management of the Nuclear Regulatory Commission (NRC) with an overview of licensing actions dealing with operating power and nonpower reactors. These reports utilize data collected from the Division of Licensing in the Office of Nuclear Reactor Regulation and are prepared by the Office of Management and Program Analysis. This summary report is published primarily for internal NRC use in managing the operating reactors licensing actions program. Its content will change based on NRC management informational requirements

  15. Operating reactors licensing actions summary. Volume 5, No. 6

    International Nuclear Information System (INIS)

    1985-08-01

    The operating reactors licensing actions summary is designed to provide the management of the Nuclear Regulatory Commission (NRC) with an overview of licensing actions dealing with operating power and nonpower reactors. These reports utilize data collected from the Division of Licensing in the Office of Nuclear Reactor Regulation and are prepared by the Office of Resource Management. This summary report is published for internal NRC use in managing the Operating Reactors Licensing Actions Program. Its content will change based on NRC management informational requirements

  16. New flux detectors for CANDU 6 reactors

    International Nuclear Information System (INIS)

    Cuttler, J.M.; Medak, N.

    1992-06-01

    CANDU reactors utilize large numbers of in-core self-powered detectors for control and protection. In the original design, the detectors (coaxial cables) were wound on carrier tubes and immersed in the heavy water moderator. Failures occurred due to corrosion and other factors, and replacement was very costly because the assemblies were not designed with maintenance in mind. A new design was conceived based on straight detectors, of larger diameter, in a sealed package of individual 'well' tubes. This protected the detectors from hostile environments and enabled individual failed sensors to be replaced by inserting spares in vacant neighbouring tubes. The new design was made retrofittable to older CANDU reactors. Provision was made for on-line scanning of the core with a miniature fission chamber. The modified detectors were tested in a lengthy development program and found to exhibit superior performance to that of the original detectors. Most of the CANDU reactors have now adopted the new design. In the case of the Gentilly-2 and Point Lepreau reactors, advantage was taken of the opportunity to redesign the detector layout (using better codes and the increased flexibility in positioning detectors) to achieve better coverage of abnormal events, leading to higher trip setpoints and wider operating margins

  17. Feasibility analysis of the utilization of moderator heat for agricultural and aquacultural purposes, Bruce nuclear power development

    International Nuclear Information System (INIS)

    1977-12-01

    A study is presented of the feasibility of using moderator reject heat from the Bruce nuclear power development either to heat greenhouses or to aid in a warm water hatchery or aquaculture operation. The study examines heat extraction and delivery plans, reliability of supply, pricing schedules, the Ontario greenhouse industry, site selection criteria, water transmission and distribution, costs, approvals required, and a construction timetable. Total system analysis shows that a greenhouse facility would be viable but the aquaculture/hatchery scheme is more cost-effective. (E.C.B.)

  18. The design and installation of a core discharge monitor for CANDU-type reactors

    International Nuclear Information System (INIS)

    Halbig, J.K.; Monticone, A.C.; Ksiezak, L.; Smiltnieks, V.

    1990-01-01

    A new type of surveillance systems that monitors neutron and gamma radiation in a reactor containment is being installed at the Ontario Hydro Darlington Nuclear Generating Station A, Unit 2. Unlike video or film surveillance that monitors mechanical motion, this system measures fuel-specific radiation emanating from irradiated fuel as it is pushed from the core of CANDU-type reactors. Proof-of-principle measurements have been carried out at Bruce Nuclear Generating Station A, Unit 3. The system uses (γ,n) threshold detectors and ionization detectors. A microprocessor-based electronics package, GRAND-II (Gamma Ray and Neutron Detector electronics package), provides detector bias, preamplifier power, and signal processing. Firmware in the GRAND-2 controls the surveillance activities, including data acquisition and a level of detector authentication, and it handles authenticated communication with a central data logging computer. Data from the GRAND-II are transferred to an MS-DOS-compatible computer and stored. These data are collected and reviewed for fuel-specific radiation signatures from the primary detector and proper ratios of signals from secondary detectors. 5 figs

  19. A progress review of Ontario Hydro's nuclear generation and heavy water production programs

    International Nuclear Information System (INIS)

    Kee, F.J.; Woodhead, L.W.

    Performance and economics of CANDU reactors in service are described. Progress of commissioning, construction and planning of reactors at Pickering, Bruce, and Darlington is outlined. Heavy water production is reviewed. (E.C.B.)

  20. Hydraulic Testing of Silurian and Ordovician Strata at the Bruce Site

    Science.gov (United States)

    Beauheim, R. L.; Avis, J. D.; Chace, D. A.; Roberts, R. M.; Toll, N. J.

    2009-05-01

    Ontario Power Generation is proposing a Deep Geologic Repository (DGR) for the long-term management of its Low and Intermediate Level Radioactive Waste (L&ILW) within a Paleozoic-age sedimentary sequence beneath the Bruce Site near Tiverton, Ontario, Canada. The concept envisions that the DGR would be excavated at a depth of approximately 680 m within the Ordovician Cobourg Formation, a massive, dense, argillaceous limestone. A key attribute of the Bruce site is the extremely low permeabilities associated with the thick Ordovician carbonate and argillaceous bedrock formations that will host and enclose the DGR. Such rock mass permeabilities are thought sufficiently low to contribute toward or govern a diffusion-dominated transport regime. To support this concept, hydraulic testing was performed in 2008 and 2009 in two deep boreholes at the proposed repository site, DGR-3 and DGR-4. The hydraulic testing was performed using a straddle-packer tool with a 30.74-m test interval. Sequential tests were performed over the entire open lengths of the boreholes from the F Unit of the Silurian Salina Formation into the Ordovician Gull River Formation, a distance of approximately 635 m. The tests consisted primarily of pressure-pulse tests, with a few slug tests performed in several of the higher permeability Silurian units. The tests are analyzed using the nSIGHTS code, which allows the entire pressure history a test interval has experienced since it was penetrated by the drill bit to be included in the test simulation. nSIGHTS also allows the model fit to the test data to be optimized over an n-dimensional parameter space to ensure that the final solution represents a true global minimum rather than simply a local minimum. The test results show that the Ordovician-age strata above the Coboconk Formation (70+ m below the Cobourg) have average horizontal hydraulic conductivities of 1E-13 m/s or less. Coboconk and Gull River hydraulic conductivities are as high as 1E-11 m

  1. Bruce NGS B risk assessment (BBRA) peer review process

    International Nuclear Information System (INIS)

    Kaasalainen, S.; Crocker, W.P.; Webb, W.A.

    2001-01-01

    Risk-informed decision making is considered an effective approach to managing the risk of nuclear power plant operation in a competitive market. Hence, increased reliance on the station probabilistic risk assessments (PRAs) to provide risk perspective inputs is inevitable. With increased reliance on the PRAs it is imperative that PRAs have the characteristics necessary to provide the required information. Recognizing the increased requirements on nuclear power plant PRAs the nuclear industry in the United States has expended significant effort over the past few years defining the required characteristics of a PRA for various applications. More recently several owners groups have drafted guidelines for PRA certification and several U.S. utilities have had their PRAs certified. During the year 2000 Ontario Power Generation, Nuclear (OPG,N) subjected the PRA of one of its stations to the U.S. style certification process. The PRA selected for this process was the Bruce B Risk Assessment (BBRA). BBRA was chosen for this process since it is the first OPG, N PRA to be used for risk-informed applications. However, the strengths of the BBRA identified from the certification process and the lessons learned are also largely applicable to the other OPG, N plant PRAs due to the use of similar methods and tools

  2. RA-6 reactor's probabilistic safety evaluation. Identification and selection of starting events

    International Nuclear Information System (INIS)

    Kay, J.; Chiossi, C.; Felizia, E.; Vallerga, H.; Kalejman, G.; Navarro, R.; Caruso, G.J.

    1987-01-01

    A summary of the 'Identification and selection of starting events' stage of the previous probabilistic safety evaluation of RA-6 reactor is presented. This evaluation was performed to verify if the safety criteria required for the licensing of RA-6 are met and to promote the diffusion of its meaning and usefulness with educational purposes. At this stage the starting events of RA-6 are determined and the probability that such events occur is calculated. The identification and selection of starting events is performed in two steps: determination of proposed starting events and determination of postulated starting events. The proposed starting events are determined by means of the master logic diagram (MLD) method, while the postulated starting events are obtained by grouping the proposed starting events. The simplifying hypothesis required for the application of MLD to the reactor are also formulated. The probability that the proposed and postulated starting events occur is afterwards calculated, adopting different fault models, in accordance with the nature of events that are considered. Conservative hypothesis on the characteristics of these events and the uncertainty of parameter values of those models are also formulated. The numerical values of the above mentioned probabilities are obtained by giving the parameters suitable values that are extracted from specialized publications. (Author)

  3. Leadership Actions to Improve Nuclear Safety Culture

    International Nuclear Information System (INIS)

    Clewett, L.K.

    2016-01-01

    The challenge many leaders face is how to effectively implement and then utilise the results of Safety Culture surveys. Bruce Power has recently successfully implemented changes to the Safety Culture survey process including how corrective actions were identified and implemented. The actions taken in response to the latest survey have proven effective with step change performance noted. Nuclear Safety is a core value for Bruce Power. Nuclear Safety at Bruce Power is based on the following four pillars: reactor safety, industrial safety, radiological safety and environmental safety. Processes and practices are in place to achieve a healthy Nuclear Safety Culture within Bruce Power such that nuclear safety is the overriding priority. This governance is based on industry leading practices which monitor, asses and take action to drive continual improvements in the Nuclear Safety Culture within Bruce Power.

  4. Verification Survey of the Building 315 Zero Power Reactor-6 Facility, Argonne National Laboratory-East, Argonne, Illinois

    International Nuclear Information System (INIS)

    W. C. Adams

    2007-01-01

    Oak Ridge Institute for Science and Education (ORISE) conducted independent verification radiological survey activities at Argonne National Laboratory's Building 315, Zero Power Reactor-6 facility in Argonne, Illinois. Independent verification survey activities included document and data reviews, alpha plus beta and gamma surface scans, alpha and beta surface activity measurements, and instrumentation comparisons. An interim letter report and a draft report, documenting the verification survey findings, were submitted to the DOE on November 8, 2006 and February 22, 2007, respectively (ORISE 2006b and 2007). Argonne National Laboratory-East (ANL-E) is owned by the U.S. Department of Energy (DOE) and is operated under a contract with the University of Chicago. Fundamental and applied research in the physical, biomedical, and environmental sciences are conducted at ANL-E and the laboratory serves as a major center of energy research and development. Building 315, which was completed in 1962, contained two cells, Cells 5 and 4, for holding Zero Power Reactor (ZPR)-6 and ZPR-9, respectively. These reactors were built to increase the knowledge and understanding of fast reactor technology. ZPR-6 was also referred to as the Fast Critical Facility and focused on fast reactor studies for civilian power production. ZPR-9 was used for nuclear rocket and fast reactor studies. In 1967, the reactors were converted for plutonium use. The reactors operated from the mid-1960's until 1982 when they were both shut down. Low levels of radioactivity were expected to be present due to the operating power levels of the ZPR's being restricted to well below 1,000 watts. To evaluate the presence of radiological contamination, DOE characterized the ZPRs in 2001. Currently, the Melt Attack and Coolability Experiments (MACE) and Melt Coolability and Concrete Interaction (MCCI) Experiments are being conducted in Cell 4 where the ZPR-9 is located (ANL 2002 and 2006). ANL has performed final

  5. Feasibility analysis of modified AL-6XN steel for structure component application in supercritical water-cooled reactor

    Institute of Scientific and Technical Information of China (English)

    Xinggang LI; Qingzhi YAN; Rong MA; Haoqiang WANG; Changchun GE

    2009-01-01

    Modified AL-6XN austenite steel was patterned after AL-6XN superaustenitic stainless steel by introducing microalloy elements such as zirconium and titanium in order to adapt to recrystallizing thermo-mechanical treatment and further improve crevice corrosion resistance. Modified AL-6XN exhibited comparable tensile strength, and superior plasticity and impact toughness to commercial AL-6XN steel. The effects of aging behavior on corrosion resistance and impact toughness were measured to evaluate the qualification of modified AL-6XN steel as an in-core component and cladding material in a supercritical water-cooled reactor. Attention should be paid to degradation in corrosion resistance and impact toughness after aging for 50 hours when modified AL-6XN steel is considered as one of the candidate materials for in-core components and cladding tubes in supercritical water-cooled reactors.

  6. AECB staff annual assessment of the Bruce A Nuclear Generating Station for the year 1994

    International Nuclear Information System (INIS)

    1995-06-01

    AECB believe that Ontario Hydro operated Bruce A in a safe manner during 1994, and that the risk to workers and the public has been maintained at an acceptably low level. Radiation doses to workers and releases to the environment were well below regulatory limits. All special safety systems met availability targets. We noted improvements in operation and maintenance but some further improvements are still required. This is particularly true of the station's compliance with the Operating Licence. AECB believe that the station continues to be well managed, with a high priority placed on safety. However, there is a need for increased capability in the area of safety analysis and assessment. 4 tabs., 4 figs

  7. Retrofitting alarm prioritization at Bruce A: strategy development and implementation experience

    International Nuclear Information System (INIS)

    Davey, E.; Hickey, D.; Babcock, B.

    1997-01-01

    A prioritization strategy for computer-displayed control room alarms has been developed for Bruce A to better assist operations staff in visually identifying key alarms and judging the relative importance of alarms. The strategy consists of assigning each alarm indicative of a problem to be addressed to one of five priority categories. Each alarm is assigned to an alarm category based on an off-line analysis of the consequence and response characteristics applicable to the alarm for three plant operating contexts. The colour of the alarm message is used to convey the priority category of each alarm in computer-based alarm displays. In addition, alarms indicative of non-problematic changes in the state of plant equipment and processes are given a separate colour assignment to visually differentiate them from alarms indicative of problems. This paper outlines the user-based approach employed in the prioritization strategy development, describes the key features of the prioritization strategy adopted, and discusses the initial experience in systematically determining the priority assignments for all 6000 computer-based alarms associated with each generating unit. (author)

  8. IGORR 6: Proceedings of the 6th meeting of the International Group On Research Reactors

    International Nuclear Information System (INIS)

    1998-01-01

    A total of 39 papers were presented in 4 technical sessions: operating research reactors (operation, upgrades, and refurbishments); operating research reactors (experience from systems for better future design); new research reactors and projects, workshop on cold neutron sources, and workshop on research and development needs. All the papers presented at the meeting are published in this Proceedings

  9. IGORR 6: Proceedings of the 6th meeting of the International Group On Research Reactors

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-07-01

    A total of 39 papers were presented in 4 technical sessions: operating research reactors (operation, upgrades, and refurbishments); operating research reactors (experience from systems for better future design); new research reactors and projects, workshop on cold neutron sources, and workshop on research and development needs. All the papers presented at the meeting are published in this Proceedings.

  10. Floral micromorphology of the genus Ensete Bruce ex Horan. (Musaceae in Thailand

    Directory of Open Access Journals (Sweden)

    Wandee Inta

    2015-09-01

    Full Text Available To fulfil scarce and incomplete information on floral micromorphology of ensets (Ensete Bruce ex Horan. in the banana family (Musaceae, a comparative anatomical study of two species: E. glaucum (Roxb. Cheesman and E. superbum (Roxb. Cheesman, native to Thailand was conducted. It was found that, apart from five fertile stamens presented in other members of the Musaceae family, both ensets possess a short staminode. It is suggested from this investigation that six is the basic number of Ensete androecial whorl and the taxa could secure the most primitive status within the family and the Zingiberales order, of which stamen numbers are reduced. The results also indicated that the vascular bundle position in compound tepal, the vascular patterns in vascular zone of ovary and cell shapes of stigma epidermis and the ovary cortex are of systematic significance in conjunction with pollen size and exine ornamentation. These useful micromorphological characters can be further applied for identification of other Ensete species distribute elsewhere in the world.

  11. Development of safety analysis methodology for moderator system failure of CANDU-6 reactor by thermal-hydraulics/physics coupling

    International Nuclear Information System (INIS)

    Kim, Jong Hyun; Jin, Dong Sik; Chang, Soon Heung

    2013-01-01

    Highlights: • Developed new safety analysis methodology of moderator system failures for CANDU-6. • The new methodology used the TH-physics coupling concept. • Thermalhydraulic code is CATHENA, physics code is RFSP-IST. • Moderator system failure ends to the subcriticality through self-shutdown. -- Abstract: The new safety analysis methodology for the CANDU-6 nuclear power plant (NPP) moderator system failure has been developed by using the coupling technology with the thermalhydraulic code, CATHENA and reactor core physics code, RFSP-IST. This sophisticated methodology can replace the legacy methodology using the MODSTBOIL and SMOKIN-G2 in the field of the thermalhydraulics and reactor physics, respectively. The CATHENA thermalhydraulic model of the moderator system can simulate the thermalhydraulic behaviors of all the moderator systems such as the calandria tank, head tank, moderator circulating circuit and cover gas circulating circuit and can also predict the thermalhydraulic property of the moderator such as moderator density, temperature and water level in the calandria tank as the moderator system failures go on. And these calculated moderator thermalhydraulic properties are provided to the 3-dimensional neutron kinetics solution module – CERBRRS of RFSP-IST as inputs, which can predict the change of the reactor power and provide the calculated reactor power to the CATHENA. These coupling calculations are performed at every 2 s time steps, which are equivalent to the slow control of CANDU-6 reactor regulating systems (RRS). The safety analysis results using this coupling methodology reveal that the reactor operation enters into the self-shutdown mode without any engineering safety system and/or human interventions for the postulated moderator system failures of the loss of heat sink and moderator inventory, respectively

  12. Severe Accident R and D for Enhanced CANDU-6 Reactors

    International Nuclear Information System (INIS)

    Nitheanandan, Thambiayah

    2012-01-01

    CANDU reactors possess a number of inherent of inherent and designed safety features that make them resistant to core damage accidents. The unique feature is the low temperature moderator surrounding the fuel channels, which can serve as an alternate heat sink. The fuel is surrounded by three water systems: heavy water primary coolant, heavy water moderator, and light water calandria vault and shield water. In addition, the liquid inventory in the steam generators is a fourth indirect heat sink, able to cool the primary coolant. The water inventories in the emergency core cooling system and the reserve water tank at the dome of the containment can also provide fuel cooling and water makeup to prevent severe core damage or mitigate the consequences of a severe core damage accident. An assessment of the adequacy of the existing severe accident knowledge base, to confidently perform consequence analyses for the Enhanced CANDU-6 reactor in compliance with regulatory requirements, was recently completed. The assessment relied on systematic Phenomena Identification and Ranking Tables (PIRT) studies completed domestically and internationally. The assessment recommends cost-effective R and D to mitigate the consequences of severe accidents and associated risk vulnerabilities

  13. Dose rates modeling of pressurized water reactor primary loop components with SCALE6.0

    International Nuclear Information System (INIS)

    Matijević, Mario; Pevec, Dubravko; Trontl, Krešimir

    2015-01-01

    Highlights: • Shielding analysis of the typical PWR primary loop components was performed. • FW-CADIS methodology was thoroughly investigated using SCALE6.0 code package. • Versatile ability of SCALE6.0/FW-CADIS for deep penetration models was proved. • The adjoint source with focus on specific material can improve MC modeling. - Abstract: The SCALE6.0 simulation model of a typical PWR primary loop components for effective dose rates calculation based on hybrid deterministic–stochastic methodology was created. The criticality sequence CSAS6/KENO-VI of the SCALE6.0 code package, which includes KENO-VI Monte Carlo code, was used for criticality calculations, while neutron and gamma dose rates distributions were determined by MAVRIC/Monaco shielding sequence. A detailed model of a combinatorial geometry, materials and characteristics of a generic two loop PWR facility is based on best available input data. The sources of ionizing radiation in PWR primary loop components included neutrons and photons originating from critical core and photons from activated coolant in two primary loops. Detailed calculations of the reactor pressure vessel and the upper reactor head have been performed. The efficiency of particle transport for obtaining global Monte Carlo dose rates was further examined and quantified with a flexible adjoint source positioning in phase-space. It was demonstrated that generation of an accurate importance map (VR parameters) is a paramount step which enabled obtaining Monaco dose rates with fairly uniform uncertainties. Computer memory consumption by the S N part of hybrid methodology represents main obstacle when using meshes with large number of cells together with high S N /P N parameters. Detailed voxelization (homogenization) process in Denovo together with high S N /P N parameters is essential for precise VR parameters generation which will result in optimized MC distributions. Shielding calculations were also performed for the reduced PWR

  14. Reactor Physics Programme

    Energy Technology Data Exchange (ETDEWEB)

    De Raedt, C

    2000-07-01

    The Reactor Physics and Department of SCK-CEN offers expertise in various areas of reactor physics, in particular in neutronics calculations, reactor dosimetry, reactor operation, reactor safety and control and non-destructive analysis on reactor fuel. This expertise is applied within the Reactor Physics and MYRRHA Research Department's own research projects in the VENUS critical facility, in the BR1 reactor and in the MYRRHA project (this project aims at designing a prototype Accelerator Driven System). Available expertise is also used in programmes external to the Department such as the reactor pressure steel vessel programme, the BR2 reactor dosimetry, and the preparation and interpretation of irradiation experiments. Progress and achievements in 1999 in the following areas are reported on: (1) investigations on the use of military plutonium in commercial power reactors; (2) neutron and gamma calculations performed for BR-2 and for other reactors; (3) the updating of neutron and gamma cross-section libraries; (4) the implementation of reactor codes; (6) the management of the UNIX workstations; and (6) fuel cycle studies.

  15. Reactor Physics Programme

    International Nuclear Information System (INIS)

    De Raedt, C.

    2000-01-01

    The Reactor Physics and Department of SCK-CEN offers expertise in various areas of reactor physics, in particular in neutronics calculations, reactor dosimetry, reactor operation, reactor safety and control and non-destructive analysis on reactor fuel. This expertise is applied within the Reactor Physics and MYRRHA Research Department's own research projects in the VENUS critical facility, in the BR1 reactor and in the MYRRHA project (this project aims at designing a prototype Accelerator Driven System). Available expertise is also used in programmes external to the Department such as the reactor pressure steel vessel programme, the BR2 reactor dosimetry, and the preparation and interpretation of irradiation experiments. Progress and achievements in 1999 in the following areas are reported on: (1) investigations on the use of military plutonium in commercial power reactors; (2) neutron and gamma calculations performed for BR-2 and for other reactors; (3) the updating of neutron and gamma cross-section libraries; (4) the implementation of reactor codes; (6) the management of the UNIX workstations; and (6) fuel cycle studies

  16. Comparison of results for burning with BWR reactors CASMO and SCALE 6.2 (TRITON / NEWT); Comparacion de los resultados de quemado para reactores BWR con CASMO y SCALE 6.2 (TRITON/NEWT)

    Energy Technology Data Exchange (ETDEWEB)

    Mesado, C.; Miro, R.; Barrachina, T.; Verdu, G.

    2014-07-01

    In this paper we compare the results from two codes burned, CASMO and SCALE 6.2 (TRITON). To do this, is simulated all segments corresponding to a boiling water reactor (BWR) using both codes. In addition, to account for different working points, simulations changing the instantaneous variables, these are repeated: void fractions (6 points), fuel temperature (6 points) and control rods (two points), with a total of 72 possible combinations of different instantaneous variables for each segment. After all simulations are completed for each segment, we can reorder the obtained cross sections, as SCALE CASMO both, to create a library of compositions nemtab format. This format is accepted by the neutronic code of nodal diffusion, PARCS v2.7. Finally compares the results obtained with PARCS and with the SIMULATE3 -SIMTAB methodology to level of full reactor. Also, we have made use of the KENO-VI and MCDANCOFF modules belonging to SCALE. The first is a Monte Carlo transport code with which you can validate the value of the multiplier, the second has been used to obtain values of Dancoff factor and increase the accuracy of model SCALE. (Author)

  17. SAFETY ANALYSIS METHODOLOGY FOR AGED CANDU® 6 NUCLEAR REACTORS

    Directory of Open Access Journals (Sweden)

    WOLFGANG HARTMANN

    2013-10-01

    Full Text Available This paper deals with the Safety Analysis for CANDU® 6 nuclear reactors as affected by main Heat Transport System (HTS aging. Operational and aging related changes of the HTS throughout its lifetime may lead to restrictions in certain safety system settings and hence some restriction in performance under certain conditions. A step in confirming safe reactor operation is the tracking of relevant data and their corresponding interpretation by the use of appropriate thermalhydraulic analytic models. Safety analyses ranging from the assessment of safety limits associated with the prevention of intermittent fuel sheath dryout for a slow Loss of Regulation (LOR analysis and fission gas release after a fuel failure are summarized. Specifically for fission gas release, the thermalhydraulic analysis for a fresh core and an 11 Effective Full Power Years (EFPY aged core was summarized, leading to the most severe stagnation break sizes for the inlet feeder break and the channel failure time. Associated coolant conditions provide the input data for fuel analyses. Based on the thermalhydraulic data, the fission product inventory under normal operating conditions may be calculated for both fresh and aged cores, and the fission gas release may be evaluated during the transient. This analysis plays a major role in determining possible radiation doses to the public after postulated accidents have occurred.

  18. Stress corrosion cracking experience in steam generators at Bruce NGS

    International Nuclear Information System (INIS)

    King, P.J.; Gonzalez, F.; Brown, J.

    1993-01-01

    In late 1990 and through 1991, units 1 and 2 at the Bruce A Nuclear Generating Station (BNGS-A) experienced a number of steam generator tube leaks. Tube failures were identified by eddy current to be circumferential cracks at U-bend supports on the hot-leg side of the boilers. In late 1991, tubes were removed from these units for failure characterization. Two active failure modes were found: corrosion fatigue in both units 1 and 2 and stress corrosion cracking (SCC) in unit 2. In unit 2, lead was found in deposits, on tubes, and in cracks, and the cracking was mixed-mode: transgranular and intergranular. This convincingly indicated the involvement of lead in the stress corrosion cracking failures. A program of inspection and tube removals was carried out to investigate more fully the extent of the problem. This program found significant cracking only in lead-affected boilers in unit 2, and also revealed a limited extent of non-lead-related intergranular stress corrosion cracking in other boilers and units. Various aspects of the failures and tube examinations are presented in this paper. Included is discussion of the cracking morphology, measured crack size distributions, and chemical analysis of tube surfaces, crack faces, and deposits -- with particular emphasis on lead

  19. Research reactor utilization. Summary reports of three study group meetings: Irradiation techniques at research reactors, held in Istanbul 15-19 November 1965; Research reactor operation and maintenance problems, held in Caracas 6-10 December 1965; and Research reactor utilization in the Far East, held in Lucas Heights 28 February - 4 March 1966

    International Nuclear Information System (INIS)

    1967-01-01

    The three sections of this book, which are summary reports of three Study Group meetings of the IAEA: Irradiation techniques at research reactors, Istanbul, 15-19 November 1965; Research reactor operation and maintenance problems, Caracas, 6-10 December 1965; and Research reactor utilization in the Far East, Lucas Heights, Australia, 28 February - 4 March 1966. These meetings were the latest in a series designed to promote efficient utilization of research reactors, to disseminate information on advances in techniques, to discuss common problems in reactor operations, and to outline some advanced areas of reactor-based research. (author)

  20. Optimization and implementation study of plutonium disposition using existing CANDU Reactors. Final report

    International Nuclear Information System (INIS)

    1996-09-01

    Since early 1994, the Department of Energy has been sponsoring studies aimed at evaluating the merits of disposing of surplus US weapons plutonium as Mixed Oxide (MOX) fuel in existing commercial Canadian Pressurized Heavy Water reactors, known as CANDU's. The first report, submitted to DOE in July, 1994 (the 1994 Executive Summary is attached), identified practical and safe options for the consumption of 50 to 100 tons of plutonium in 25 years in some of the existing CANDU reactors operating the Bruce A generating station, on Lake Huron, about 300 km north east of Detroit. By designing the fuel and nuclear performance to operate within existing experience and operating/performance envelope, and by utilizing existing fuel fabrication and transportation facilities and methods, a low cost, low risk method for long term plutonium disposition was developed. In December, 1995, in response to evolving Mission Requirements, the DOE requested a further study of the CANDU option with emphasis on more rapid disposition of the plutonium, and retaining the early start and low risk features of the earlier work. This report is the result of that additional work

  1. Neutronics modeling of TRIGA reactor at the University of Utah using agent, KENO6 and MCNP5 codes

    International Nuclear Information System (INIS)

    Yang, X.; Xiao, S.; Choe, D.; Jevremovic, T.

    2010-01-01

    The TRIGA reactor at the University of Utah is modelled in 2D using the AGENT state-of-the-art methodology based on the Method of Characteristics (MOC) and R-function theory supporting detailed reactor analysis of reactor geometries of any type. The TRIGA reactor is also modelled using KENO6 and MCNP5 for comparison. The spatial flux and reaction rates distribution are visualized by AGENT graphics support. All methodologies are in use in to study the effect of different fuel configurations in developing practical educational exercises for students studying reactor physics. At the University of Utah we train graduate and undergraduate students in obtaining the Nuclear Regulatory Commission license in operating the TRIGA reactor. The computational models as developed are in support of these extensive training classes and in helping students visualize the reactor core characteristics in regard to neutron transport under various operational conditions. Additionally, the TRIGA reactor is under the consideration for power uprate; this fleet of computational tools once benchmarked against real measurements will provide us with validated 3D simulation models for simulating operating conditions of TRIGA. (author)

  2. Experience in ultrasonic gap measurement between calandria tubes and liquid injection shutdown systems nozzles in Bruce Nuclear Generating Station

    International Nuclear Information System (INIS)

    Abucay, R.C.; Mahil, K.S.; Goszczynski, J.J.

    1995-01-01

    The gaps between calandria tubes (CT) and Liquid Injection Shutdown System (LISS) nozzles at the Bruce Nuclear Generating Station ''A'' (Bruce A) are known to decrease with time due to radiation induced creep/sag of the calandria tubes. If this gap decreases to a point where the calandria tubes come into contact with the LISS nozzle, the calandria tubes could fail as a result of fretting damage. Proximity measurements were needed to verify the analytical models and ensure that CT/LISS nozzle contact does not occur earlier than predicted. The technique used was originally developed at Ontario Hydro Technologies (formerly Ontario Hydro Research Division) in the late seventies and put into practical use by Research and Productivity Council (RPC) of New Brunswick, who carried out similar measurements at Point Lepreau NGS in 1989 and 1991. The gap measurement was accomplished y inserting an inspection probe, containing four ultrasonic transducers (2 to measure gaps and 2 to check for probe tilt) and a Fredericks electrolytic potentiometer as a probe rotational sensor, inside LISS Nozzle number-sign 7. The ultrasonic measurements were fed to a system computer that was programmed to convert the readings into fully compensated gaps, taking into account moderator heavy water temperature and probe tilt. Since the measured gaps were found to be generally larger than predicted, the time to CT/LISS nozzle contact is now being re-evaluated and the planned LISS nozzle replacement will likely be deferred, resulting in considerable savings

  3. Event review: International Knapping Workshop, with Bruce Bradley, Fazenda Monte Alto, Dourado, SP (Brazil

    Directory of Open Access Journals (Sweden)

    Elisa Theodora Adriana van Veldhuizen

    2016-07-01

    Full Text Available The event took place from 3 till 8 July 2016 at Fazenda Monte Alto, Dourado, SP, Brazil. The aim of the course was to provide intensive knapping training in order to enhance analytical methods and procedures. This training was not only for students, but also professionals who were interested in the course. The course was given by Bruce Bradley (University of Exeter, who has extensive experience with Stone Age technologies and experimental archaeology. Mercedes Okumura (PPGArq, National Museum, Federal University of Rio de Janeiro and Astolfo G. M. Araujo (Museum of Archaeology and Ethnology, University of São Paulo organized the course, which was sponsored by Fazenda Monte Alto, Café Helena, and the British Academy, Newton Mobility Grants Scheme (NG140077. The workshop had 15 participants from Brazil, Uruguay, the Netherlands and Canada.

  4. Study on the use of slightly enriched uranium fuel cycle in an existing CANDU 6 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Yeom, Choong Sub; Kim, Hyun Dae [Institute for Advanced Engineering, Seoul (Korea, Republic of)

    1998-12-31

    To test the viability of CANFLEX-SEU bundles in an existing CANDU 6 reactor, core follow-up simulation has been carried out using the reactor fueling simulation program of the CANDU 6, RFSP computer code, and a lattice physics code, WIMS-AECL. During the core follow-up, bundle and channel powers and zone levels have been checked against their operating limits at each simulation. It is observed from the simulation results that an equilibrium core loaded with 0.9 w/o CANFLEX-SEU bundles could be refueled and maintained for 550 FPD without any significant violations in the channel and bundle power limits and the permissible operating range of the liquid zone controllers. 8 refs., 2 figs., 1 tab. (Author)

  5. Study on the use of slightly enriched uranium fuel cycle in an existing CANDU 6 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Yeom, Choong Sub; Kim, Hyun Dae [Institute for Advanced Engineering, Seoul (Korea, Republic of)

    1997-12-31

    To test the viability of CANFLEX-SEU bundles in an existing CANDU 6 reactor, core follow-up simulation has been carried out using the reactor fueling simulation program of the CANDU 6, RFSP computer code, and a lattice physics code, WIMS-AECL. During the core follow-up, bundle and channel powers and zone levels have been checked against their operating limits at each simulation. It is observed from the simulation results that an equilibrium core loaded with 0.9 w/o CANFLEX-SEU bundles could be refueled and maintained for 550 FPD without any significant violations in the channel and bundle power limits and the permissible operating range of the liquid zone controllers. 8 refs., 2 figs., 1 tab. (Author)

  6. Research reactor 'A' 6.5/10 MW; Istrazivacki reaktor 'A' 6,5/10 MW

    Energy Technology Data Exchange (ETDEWEB)

    Petrovic, M [Institute of nuclear sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1961-07-01

    This booklet includes a short description of the RA research reactor with basic properties of its components: control and safety system, heavy water system, technical water cooling system, heavy water distillation system, cover gas system, dosimetry control system, power supply system. It is used for fundamental research in reactor and nuclear physics, isotope production, materials testing.

  7. After Action Report: Advanced Test Reactor Complex 2015 Evaluated Drill October 6, 2015

    Energy Technology Data Exchange (ETDEWEB)

    Holmes, Forest Howard [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-11-01

    The Advanced Test Reactor (ATR) Complex, operated by Battelle Energy Alliance, LLC, at the Idaho National Laboratory (INL) conducted an evaluated drill on October 6, 2015, to allow the ATR Complex emergency response organization (ERO) to demonstrate the ability to respond to and mitigate an emergency by implementing the requirements of DOE O 151.1C, “Comprehensive Emergency Management System.”

  8. My City of Ruins: Bruce Springsteen e l’utopia fra le rovine

    Directory of Open Access Journals (Sweden)

    Enrico Botta

    2011-09-01

    Full Text Available The paper focuses on My City of Ruins, the song that Bruce Springsteen sang—ten days after the 09/11 terrorist attacks—for "America: A Tribute to Heroes" and that was released in the concept album The Rising in 2002. The essay aims to highlight how the song describes the post 09/11 New York City by opposing the themes of “ruins” and “utopia.” From a textual and musical point of view, My City of Ruins is, in fact, composed of a double structure that balances different feelings: the fear, pain, and loneliness of the victims, in the rock-blues first section; the faith, love, and hope, in the gospel second part. Furthermore, the paper tries to point out how My City of Ruins no longer describes the symbolic ruins of a foreign past—in line with the nineteenth and twentieth-century American cultural tradition of the Grand Tour—but defines the physical signs of a definitively collapsed “American dream,” which can survive only in a utopian and spiritual “Promised Land.”

  9. Multipurpose research reactors

    International Nuclear Information System (INIS)

    1988-01-01

    The international symposium on the utilization of multipurpose research reactors and related international co-operation was organized by the IAEA to provide for information exchange on current uses of research reactors and international co-operative projects. The symposium was attended by about 140 participants from 36 countries and two international organizations. There were 49 oral presentations of papers and 24 poster presentations. The presentations were divided into 7 sessions devoted to the following topics: neutron beam research and applications of neutron scattering (6 papers and 1 poster), reactor engineering (6 papers and 5 posters), irradiation testing of fuel and material for fission and fusion reactors (6 papers and 10 posters), research reactor utilization programmes (13 papers and 4 posters), neutron capture therapy (4 papers), neutron activation analysis (3 papers and 4 posters), application of small reactors in research and training (11 papers). A separate abstract was prepared for each of these papers. Refs, figs and tabs

  10. Removal of bulk contaminants from radioactive waste water at Bruce A using a clay based flocculent system

    International Nuclear Information System (INIS)

    Davloor, R.; Harper, B.

    2011-01-01

    Bruce Power's Bruce Nuclear Generating Station 'A', located on Lake Huron, has a treatment system that processes all aqueous radioactive waste water originating from the station. This Active Liquid Waste Treatment System (ALWTS) consists of collection tanks for the collection of radioactive waste water, a Pre-Treatment System (PTS) for the removal of bulk contaminants and suspended solids, a Reverse Osmosis System (ROS) to remove dissolved solids, an Evaporation and Solidification System (ESS) to concentrate and immobilize solids contained in concentrated waste streams from the ROS, and discharge tanks for the dispersal of the treated water. The ALWTS has been in continuous service since 1999 and is used to treat approximately 100,000 litres of Active Liquid Waste (ALW) each day. With the exception of tritium, it discharges waste water containing near zero concentrations of radioactive and conventional contaminants to the lake. The original design of the Bruce A ALWTS used a Backwashable Filtration System (BFS) to provide solids free water to the ROS, as measured by the Silt Density Index (SDI). During commissioning, the BFS was not successful in backwashing the solids from the filter elements. For approximately one year, a temporary solution was implemented using a Disposable Filtration System (DFS). A cationic polymer was added upstream of the DFS to agglomerate the solids. The system proved to be highly unreliable. It was difficult to agglomerate solids in the waste stream containing high amounts of detergent. As a result, DFS consumption was high and very costly. The SDI specification for the RO membrane was not always met, resulting in a quick decline of performance of the first stage ROS membranes in the treatment process. In addition, the excess cationic polymer in the RO feed caused the membranes to become fouled. In-house station staff, together with personnel from Colloid Environmental Technologies (CETCO) Company, worked to develop and

  11. Removal of bulk contaminants from radioactive waste water at Bruce A using a clay based flocculent system

    Energy Technology Data Exchange (ETDEWEB)

    Davloor, R.; Harper, B. [Bruce Power, Tiverton, ON (Canada)

    2011-07-01

    Bruce Power's Bruce Nuclear Generating Station 'A', located on Lake Huron, has a treatment system that processes all aqueous radioactive waste water originating from the station. This Active Liquid Waste Treatment System (ALWTS) consists of collection tanks for the collection of radioactive waste water, a Pre-Treatment System (PTS) for the removal of bulk contaminants and suspended solids, a Reverse Osmosis System (ROS) to remove dissolved solids, an Evaporation and Solidification System (ESS) to concentrate and immobilize solids contained in concentrated waste streams from the ROS, and discharge tanks for the dispersal of the treated water. The ALWTS has been in continuous service since 1999 and is used to treat approximately 100,000 litres of Active Liquid Waste (ALW) each day. With the exception of tritium, it discharges waste water containing near zero concentrations of radioactive and conventional contaminants to the lake. The original design of the Bruce A ALWTS used a Backwashable Filtration System (BFS) to provide solids free water to the ROS, as measured by the Silt Density Index (SDI). During commissioning, the BFS was not successful in backwashing the solids from the filter elements. For approximately one year, a temporary solution was implemented using a Disposable Filtration System (DFS). A cationic polymer was added upstream of the DFS to agglomerate the solids. The system proved to be highly unreliable. It was difficult to agglomerate solids in the waste stream containing high amounts of detergent. As a result, DFS consumption was high and very costly. The SDI specification for the RO membrane was not always met, resulting in a quick decline of performance of the first stage ROS membranes in the treatment process. In addition, the excess cationic polymer in the RO feed caused the membranes to become fouled. In-house station staff, together with personnel from Colloid Environmental Technologies (CETCO) Company, worked to develop and

  12. Plutonium and minor actinides management in thermal high - temperature reactors - the EU FP6 project puma

    International Nuclear Information System (INIS)

    Kuijper, J. C.

    2007-01-01

    The High Temperature gas-cooled Reactor (HTR) can fulfil a very useful niche for the purposes of Pu and Minor Actinide (MA) incineration due to its unique and unsurpassed safety features, as well as to the attractive incentives offered by the nature of the coated particle (CP) fuel. No European reactor of this type is currently available, but there has been, and still is, considerable interest internationally. Decisions to construct such a reactor in China and in South Africa have already been made or are about to be made. Apart from the unique and unsurpassed safety features offered by this reactor type, the nature of the CP fuel offers a number of attractive characteristics. In particular, it can withstand burn-ups far beyond that in either LWR or FR systems. Demonstrations as high as 75% FIMA have been achieved. The coated particle itself offers significantly improved proliferation resistance, and finally with a correct choice of the kernel composition, it can be a very effective support for direct geological disposal of the fuel. The overall objective of the PUMA project, a Specific Targeted Research Project (STREP) within the European Union 6th Framework (EU FP6), is to investigate the possibilities for the utilisation and transmutation of plutonium and especially minor actinides in contemporary and future (high temperature) gas-cooled reactor designs, which are promising tools for improving the sustainability of the nuclear fuel cycle. This contributes to the reduction of Pu and MA stockpiles, and also to the development of safe and sustainable reactors for CO 2 -free energy generation. A number of important issues concerning the use of Pu and MA in gas-cooled reactors have already been dealt with in other projects, or are being treated in ongoing projects, e.g. as part of EU FP6. However, further steps are required to demonstrate the potential of HTRs as Pu/MA transmuters based on realistic/feasible designs of CP Pu/MA fuel and the PUMA focuses on necessary

  13. Annual report, 1978

    International Nuclear Information System (INIS)

    1979-04-01

    In 1978, for the first time, nuclear generators supplied more electricity than coal-fired units: 30 percent of the total compared with 28 percent for coal. Energy demand in Ontario was up by 2.7 percent. No new commitments for generating stations were made, and work on committed stations was to be slowed until the generation expansion program had been fully reviewed. Atomic Energy of Canada Ltd. and Ontario Hydro have agreed to develop a nuclear wastes demonstration facility. The Select Committee of the Ontario Legislature on Ontario Hydro affairs investigated the costs of the Bruce heavy water plants and found no evidence of mismanagement. The Royal Commission on Electric Power Planning issued an interim report on nuclear power which recognized the need for and safety of the CANDU system. Reactors at Pickering and Bruce achieved an overall capacity factor of 81 percent. The third Bruce A unit was started up. Work on Bruce B and Pickering B was well underway. Bruce Heavy Water Plant B was virtually complete, but work was stopped on the second half of the Bruce D plant. Plans for the first half of Bruce D will be reviewed. Site preparation and excavation continued for the Darlington generating station. (LL)

  14. Atomic Energy of Canada Limited annual report 2000-2001

    International Nuclear Information System (INIS)

    2001-01-01

    This is the annual report of the Atomic Energy of Canada Limited for the year ending March 31, 2001 and summarizes the activities of AECL during the period 2000-2001. The activities covered in this report include the CANDU reactor business, with progress being reported in the construction of two CANDU 6 reactors for the Qinshan CANDU project in China, the anticipated completion of Cernavoda unit 2, the completion of spent fuel storage at Cernavoda unit 1 in Romania, as well as the service business with New Brunswick Power, Ontario Power Generation, Bruce Power and Hydro Quebec in the refurbishment of operating, CANDU reactors. In the R and D programs discussions continue on funding for the Canadian Neutron Facility for Materials Research (CNF) and progress on the Maple medical isotope reactor

  15. Atomic Energy of Canada Limited annual report 2000-2001

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This is the annual report of the Atomic Energy of Canada Limited for the year ending March 31, 2001 and summarizes the activities of AECL during the period 2000-2001. The activities covered in this report include the CANDU reactor business, with progress being reported in the construction of two CANDU 6 reactors for the Qinshan CANDU project in China, the anticipated completion of Cernavoda unit 2, the completion of spent fuel storage at Cernavoda unit 1 in Romania, as well as the service business with New Brunswick Power, Ontario Power Generation, Bruce Power and Hydro Quebec in the refurbishment of operating, CANDU reactors. In the R and D programs discussions continue on funding for the Canadian Neutron Facility for Materials Research (CNF) and progress on the Maple medical isotope reactor.

  16. Parametric study of moderator heat exchanger for Candu 6 advanced reactor

    International Nuclear Information System (INIS)

    Umar, Efrizon; Vecchiarelli, Jack

    2000-01-01

    The passive moderator system for Candu 6 advanced reactor require moderator heat exchanger with the small size and the low resistance coefficient of the shell-side. The study is to determine the required size of moderator heat exchanger, and to calculate the shell side of resistance coefficient have been done. Using computer code CATHENA, it is concluded that the moderator heat exchanger can be used at full power-normal operation condition, especially for the cases with 3600 to 8100 number of tube and 15.90 mm tube diameter. This study show that the proposed moderator heat exchanger have given satisfactory results

  17. Nuclear process steam for industry

    International Nuclear Information System (INIS)

    Seddon, W.A.

    1981-11-01

    A joint industrial survey funded by the Bruce County Council, the Ontario Energy Corporation and Atomic Energy of Canada Limited was carried out with the cooperation of Ontario Hydro and the Ontario Ministry of Industry and Tourism. Its objective was to identify and assess the future needs and interest of energy-intensive industries in an Industrial Energy Park adjacent to the Bruce Nuclear Power Development. The Energy Park would capitalize on the infrastructure of the existing CANDU reactors and Ontario Hydro's proven and unique capability to produce steam, as well as electricity, at a cost currently about half that from a comparable coal-fired station. Four industries with an integrated steam demand of some 1 x 10 6 lb/h were found to be prepared to consider seriously the use of nuclear steam. Their combined plants would involve a capital investment of over $200 million and provide jobs for 350-400 people. The high costs of transportation and the lack of docking facilities were considered to be the major drawbacks of the Bruce location. An indication of steam prices would be required for an over-all economic assessment

  18. Simulation of the Point Lepreau core-follow history with SORO

    Energy Technology Data Exchange (ETDEWEB)

    Shanes, F.C.; Olive, C.G.; Cheng, I. [Nuclear Safety Solutions Limited, Toronto, Ontario (Canada); Banica, C. [Ontario Power Generation, Ajax, Ontario (Canada); Newman, C. [NB Power Nuclear, Point Lepreau Generating Station, Lepreau, New Brunswick (Canada); Nainer, O. [Bruce Power, Toronto, Ontario (Canada)

    2006-07-01

    The core tracking SORO program calculates the flux, burn-ups, bundle and channel powers, and is used for Ontario Power Generation and Bruce Power reactors. This paper presents the results of a comparison of the SORO cell fluxes against the Point Lepreau CANDU-6 measured flux data. A SORO model was created for the Point Lepreau reactor, and simulations were carried out to compare the SORO fluxes to the Travelling Flux Detector (TFD) scans and one year of operating history. Considering the good agreement between measured and computed fluxes, the results provide confidence that SORO accurately calculates the cell fluxes and bundle powers. (author)

  19. Simulation of the Point Lepreau core-follow history with SORO

    International Nuclear Information System (INIS)

    Shanes, F.C.; Olive, C.G.; Cheng, I.; Banica, C.; Newman, C.; Nainer, O.

    2006-01-01

    The core tracking SORO program calculates the flux, burn-ups, bundle and channel powers, and is used for Ontario Power Generation and Bruce Power reactors. This paper presents the results of a comparison of the SORO cell fluxes against the Point Lepreau CANDU-6 measured flux data. A SORO model was created for the Point Lepreau reactor, and simulations were carried out to compare the SORO fluxes to the Travelling Flux Detector (TFD) scans and one year of operating history. Considering the good agreement between measured and computed fluxes, the results provide confidence that SORO accurately calculates the cell fluxes and bundle powers. (author)

  20. Analyses of fluid flow and heat transfer inside calandria vessel of CANDU-6 reactor using CFD

    International Nuclear Information System (INIS)

    Yu, Seon Oh; Kim, Man Woong; Kim, Hho Jung

    2005-01-01

    In a CANDU (CANada Deuterium Uranium) reactor, fuel channel integrity depends on the coolability of the moderator as an ultimate heat sink under transient conditions such as a Loss Of Coolant Accident (LOCA) with coincident Loss Of Emergency Core Cooling (LOECC). as well as normal operating conditions. This study presents assessments of moderator thermal-hydraulic characteristics in the normal operating conditions and one transient condition for CANDU-6 reactors, using a general purpose three-dimensional computational fluid dynamics code. First, an optimized calculation scheme is obtained by many-sided comparisons of the predicted results with the related experimental data, and by evaluating the fluid flow and temperature distributions. Then, using the optimized scheme, analyses of real CANDU-6 in normal operating conditions and the transition condition have been performed. The present model successfully predicted the experimental results and also reasonably assessed the thermal-hydraulic characteristics of a real CANDU-6 with 380 fuel channels. A flow regime map with major parameters representing the flow pattern inside a calandria vessel has also proposed to be used as operational and/or regulatory guidelines

  1. Characterization and dissolution studies of Bruce Unit 3 steam generator secondary side deposits

    International Nuclear Information System (INIS)

    Semmler, J.

    1998-01-01

    The physical and chemical properties of secondary side steam generator deposits in the form of powder and flake obtained from Bruce Nuclear Generating Station A (BNGS A) Unit 3 were studied. The chemical phases present in both types of deposits, collected prior to the 1994 chemical cleaning during the pre-clean water lancing campaign, were magnetite (Fe 3 O 4 ), metallic copper (Cu), hematite (Fe 2 O 3 ) and cuprous oxide (Cu 2 O). The major difference between the chemical composition of the powder and the flake was the presence of zinc silicate (Zn 2 SiO 4 ) and several unidentified silicate phases containing Ca, Al, Mn, and Mg in the flake. The flake deposit had high hardness values, high electrical resistivity, low porosity and a lower dissolution rate in the EPRI-SGOG (Electric Power Research Institute-Steam Generator Owner's Group) chemical cleaning solvents compared to the powder deposit. Differences in the deposit properties after chemical cleaning of the Unit 3 steam generators and after laboratory cleaning were noted. The presence of silicates in the deposit inhibit magnetite dissolution

  2. Nuclear reactors situation in Japan after the major earthquake of March 11, 2011. March 17, 2011, 6:00 AM status

    International Nuclear Information System (INIS)

    2011-01-01

    This situation note is established according to the information gained on March 17, 2011, at 6:00 AM, by the crisis centre of the French institute of radiation protection and nuclear safety (IRSN). The situation of all 6 reactors of the Fukushima I site (Dai-ichi) and of their spent fuel pools, as well as the situation of the reactors No. 1, 2, 3 and 4 of the Fukushima II site (Daini), and of the Onagawa and Tokai power plants is briefly presented with the progress of the accident management actions. (J.S.)

  3. Criticality analysis of IPEN/MB-01 reactor using scale 6.0 and ENDF/B VII

    International Nuclear Information System (INIS)

    Cardoso, Fabiano S.; Salome, Jean; Pereira, Claubia; Fortini, Angela

    2015-01-01

    Since 1988, the IPEN/MB-01 reactor has been utilized for basic reactor physics research and as an instructional laboratory system. A series of experiments was conducted, and many of the components were evaluated in LEU-COMP-THERM-077 and LEU-COMP-THERM-089 benchmarks. In this work, we will compare the benchmark value references, with the newest ENDF/BVII libraries for neutron transport calculations through KENO-VI of the SCALE 6.0 codes. The 3D reactor model was simulated using 238 groups of energy and continuous energy libraries. The idea was to obtain, on this work, preliminary values of effective neutron multiplication factor to guide future work to get nuclear data as neutron flux, depleted fuel isotopic composition and generate homogenized and collapsed cross-sections libraries by few neutron energy groups to be used by other neutronic codes. It is expected that this study will produce a research source to be used as a support for future works employing such codes for nuclear safety criticality analysis and to verify compliance with the requirements of safety standards for nuclear fuel materials. (author)

  4. Analysis of Moderator System Failure Accidents by Using New Method for Wolsong-1 CANDU 6 Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Dongsik; Kim, Jonghyun; Cho, Cheonhwey [Atomic Creative Technology Co., Ltd., Daejeon (Korea, Republic of); Kim, Sungmin [Korea Hydro and Nuclear Power Co., Ltd., Daejeon (Korea, Republic of)

    2013-05-15

    To reconfirm the safety of moderator system failure accidents, the safety analysis by using the reactor physics code, RFSP-IST, coupled with the thermal hydraulics code, CATHENA is performed additionally. In the present paper, the newly developed analysis method is briefly described and the results obtained from the moderator system failure accident simulations for Wolsong-1 CANDU 6 reactor by using the new method are summarized. The safety analysis of the moderator system failure accidents for Wolsong-1 CANDU 6 reactor was carried out by using the new code system, i. e., CATHENA and RFSP-IST, instead of the non-IST old codes, namely, SMOKIN G-2 and MODSTBOIL. The analysis results by using the new method revealed as same with the results by using the old method that the fuel integrity is warranted because the localized power peak remained well below the limits and, most importantly, the reactor operation enters into the self-shutdown mode due to the substantial loss of moderator D{sub 2}O inventory from the moderator system. In the analysis results obtained by using the old method, it was predicted that the ROP trip conditions occurred for the transient cases which are also studied in the present paper. But, in the new method, it was found that the ROP trip conditions did not occur. Consequently, in the safety analysis performed additionally by using the new method, the safety of moderator system failure accidents was reassured. In the future, the new analysis method by using the IST codes instead of the non-IST old codes for the moderator system failure accidents is strongly recommended.

  5. Comparison of CFD Simulations of Moderator Circulation Phenomena for a CANDU-6 Reactor and MCT Facility

    International Nuclear Information System (INIS)

    Kim, Hyoung Tae; Cha, Jae Eun Cha; Seo, Han

    2013-01-01

    The Korea Atomic Energy Research Institute is constructing a Moderator Circulation Test (MCT) facility to simulate thermal-hydraulic phenomena in a 1/4 scale-down moderator tank similar to that in a prototype power plant during steady state operation and accident conditions. In the present study, two numerical CFD simulations for the prototype and scaled-down moderator tanks were carried out to check whether the moderator flow and temperature patterns of both the prototype reactor and scaled-down facility are identical. Two different sets of simulations of the moderator circulation phenomena were performed for a CANDU-6 reactor and MCT facility. The results of both simulations were compared to study the effects of scaling on the moderator flow and temperature patterns. There is no significant difference in the results between the prototype and scaled-down model. It was concluded that the present scaling method is properly employed to model the real reactor in the MCT facility

  6. Comparison of CFD Simulations of Moderator Circulation Phenomena for a CANDU-6 Reactor and MCT Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoung Tae; Cha, Jae Eun Cha; Seo, Han [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    The Korea Atomic Energy Research Institute is constructing a Moderator Circulation Test (MCT) facility to simulate thermal-hydraulic phenomena in a 1/4 scale-down moderator tank similar to that in a prototype power plant during steady state operation and accident conditions. In the present study, two numerical CFD simulations for the prototype and scaled-down moderator tanks were carried out to check whether the moderator flow and temperature patterns of both the prototype reactor and scaled-down facility are identical. Two different sets of simulations of the moderator circulation phenomena were performed for a CANDU-6 reactor and MCT facility. The results of both simulations were compared to study the effects of scaling on the moderator flow and temperature patterns. There is no significant difference in the results between the prototype and scaled-down model. It was concluded that the present scaling method is properly employed to model the real reactor in the MCT facility.

  7. A global model for SF6 plasmas coupling reaction kinetics in the gas phase and on the surface of the reactor walls

    International Nuclear Information System (INIS)

    Kokkoris, George; Panagiotopoulos, Apostolos; Gogolides, Evangelos; Goodyear, Andy; Cooke, Mike

    2009-01-01

    Gas phase and reactor wall-surface kinetics are coupled in a global model for SF 6 plasmas. A complete set of gas phase and surface reactions is formulated. The rate coefficients of the electron impact reactions are based on pertinent cross section data from the literature, which are integrated over a Druyvesteyn electron energy distribution function. The rate coefficients of the surface reactions are adjustable parameters and are calculated by fitting the model to experimental data from an inductively coupled plasma reactor, i.e. F atom density and pressure change after the ignition of the discharge. The model predicts that SF 6 , F, F 2 and SF 4 are the dominant neutral species while SF 5 + and F - are the dominant ions. The fit sheds light on the interaction between the gas phase and the reactor walls. A loss mechanism for SF x radicals by deposition of a fluoro-sulfur film on the reactor walls is needed to predict the experimental data. It is found that there is a net production of SF 5 , F 2 and SF 6 , and a net consumption of F, SF 3 and SF 4 on the reactor walls. Surface reactions as well as reactions between neutral species in the gas phase are found to be important sources and sinks of the neutral species.

  8. Neutronics investigation of CANDU deuterium uranium 6 reactor fueled (transuranic-TH) O-2 using a computational method

    Energy Technology Data Exchange (ETDEWEB)

    Gholamzadeh, Zohreh; Mirvakili, Seyed Mohammad; Khalafi, Hossein [Reactor Research School, Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of)

    2015-02-15

    241Am, 243Am, and 237Np isotopes are among the most radiotoxic components of spent nuclear fuel. Recently, researchers have planned different incineration scenarios for the highly radiotoxic elements of nuclear waste in critical reactors. Computational methods are widely used to predict burnup rates of such nuclear wastes that are used under fuel matrixes in critical reactors. In this work, the Monte Carlo N-particle transport code was used to calculate the neutronic behavior of a transuranic (TRU)-bearing CANada Deuterium Uranium 6 reactor. The computational data showed that the 1.0% TRU-containing thorium-based fuel matrix presents higher proliferation resistance and TRU depletion rate than the other investigated fuel Matrixes. The fuel matrix includes higher negative temperature reactivity coefficients as well. The investigated thorium-based fuel matrix can be successfully used to decrease the production of highly radiotoxic isotopes.

  9. Consolidation of the neutron spectrum in the RA-6 reactor

    International Nuclear Information System (INIS)

    Bazzana, S.; Chiaraviglio, N.

    2013-01-01

    Unfolding procedures can be used to determine the neutron or gamma spectrum in a multigroup structure from experimental and calculation results. In this way, it is possible to adjust with high reliability magnitudes that cannot be directly measured. For neutron unfolding it is necessary the use of a set of detectors with different energetic response. In this work we describe two unfolding experiences in different positions of the RA-6 reactor of the Bariloche Atomic Centre. One of them consisted in the unfolding in an incore position and the other one in the BNCT facility beam.Experimental techniques and neutron detectors for each experience are described along with the correction factors that must be taken into account for each experience. In both cases there is good agreement between measured and adjusted quantities. (author) [es

  10. Calibration method of liquid zone controller using the ex-core detector signal of CANDU 6 reactor

    International Nuclear Information System (INIS)

    Park, D.H.; Lee, E.K.; Shin, H.C.; Bae, S.M.; Hong, S.Y.

    2013-01-01

    Highlights: ► We developed a new LZC calibration method and measurement system. ► Photo-neutron effect, reactor core size, and detector position were evaluated and tested. ► We applied the new method and system to Wolsong NPP Unit 1. ► The LZC calibration test was well completed, and the requirement of the test was satisfied. - Abstract: The Phase-B test (low-power reactor physics test) is one of the commissioning tests for Canada Deuterium Uranium (CANDU) reactors that ensures the safe and reliable operation of the core during the design lifetime. The Phase-B test, which includes the approach to the first criticality at low reactor powers, is performed to verify the feasibility of the reactor’s physics design and to ensure the integrity of the control and protection facilities. The commissioning testing of pressurized heavy water moderated reactors (PHWRs) is usually performed only once (at the initial commissioning after construction). The large-scale facilities of the Wolsong nuclear power plant (NPP) Unit 1 have been gradually improved since May 2009 to extend its lifetime. The refurbishment was completed in April 2011 – then this NPP has been in operation again. We discusses the new methodology and measurement system that uses an ex-core detector signal for liquid zone controller (LZC) calibration of the Phase-B test instead of conventional methods. The inverse kinetic equation in the reactivity calculator is modified to treat the 17 delayed neutron groups including 11 photo-neutron fractions. The signal acquisition resolution of the reactivity calculator was enhanced and installed reactivity calculating module by each channel. The ex-core detector was confirmed to be applicable to a large reactor core, such as the CANDU 6 by comparison with the in-core flux detector signal. A preliminary test was performed in Wolsong NPP Unit 2 to verify the robustness of the reactivity calculator. This test convincingly demonstrated that the reactivity calculator

  11. Reconstruction of intra-bundle fission density profile during a postulated LOCA in a CANDU reactor

    Energy Technology Data Exchange (ETDEWEB)

    Ilas, D. [Oak Ridge National Laboratory (United States); Rahnema, F. [Georgia Inst. of Technology (United States); Nuclear and Radiological Engineering/Medical Physics Programs, George W. Woodruff School, Georgia Inst. of Technology, Atlanta, GA 30332-0405 (United States); Serghiuta, D. [Canadian Nuclear Safety Commission (Canada); Sarsour, H.; Turinsky, P. J. [North Carolina State Univ. (United States); Stamm' ler, R. [Studsvik Scandpower AS (Norway)

    2006-07-01

    In this paper, results related to the reconstruction of intra-bundle fission density profile for a 37-pin CANDU-6 bundle with the highest enthalpy deposition during a postulated large LOCA stagnation break in a Bruce B core are presented. Bruce B is a nuclear power plant in Kincardine, Ontario (Canada)), on the shores of Lake Huron with 4 CANDU reactors that are rated at about 750 MWe. The reconstruction of the fuel pin fission densities is based on steady-state, three-dimensional simulations with the Monte Carlo code MCNP for a subset of 27 out of 69 time steps during the first two seconds of the power pulse predicted for the fuel bundle at core location V13/8. Two-group cross section data libraries are generated for MCNP at each time step by the lattice depletion neutron transport code HELIOS-1.7. To include the effect of the surrounding core environment, the calculations are performed with time-dependent albedo boundary conditions inferred from a full core simulation of the transient by the nodal diffusion code NESTLE with HELIOS homogenized cross-sections. It is found that the local peaking factor (LPF) in the outer ring varies during the transient, but never exceeds its value before the transient. Inclusion of the core environment increases the LPF in the outer ring. For the analyzed case, the increase is 0.72% with a relative error of 0.01% for the LPF before the transient and 0.55% (with a relative error of 0.01%) for the maximum average LPF during the transient. The latter is based on only four selected transient time points. Note that the immediate environment of the 'hot bundle' does not contain any reactivity devices or other perturbing factors. As a result, the increases observed in the LPF in the outer ring may not be representative of the situations in which 'other' core environment perturbing factors are present. To determine the effect of these factors on the LPF, further analyses of a bundle in the proximity of control devices

  12. Hybrid reactors

    International Nuclear Information System (INIS)

    Moir, R.W.

    1980-01-01

    The rationale for hybrid fusion-fission reactors is the production of fissile fuel for fission reactors. A new class of reactor, the fission-suppressed hybrid promises unusually good safety features as well as the ability to support 25 light-water reactors of the same nuclear power rating, or even more high-conversion-ratio reactors such as the heavy-water type. One 4000-MW nuclear hybrid can produce 7200 kg of 233 U per year. To obtain good economics, injector efficiency times plasma gain (eta/sub i/Q) should be greater than 2, the wall load should be greater than 1 MW.m -2 , and the hybrid should cost less than 6 times the cost of a light-water reactor. Introduction rates for the fission-suppressed hybrid are usually rapid

  13. Generation IV reactors: international projects

    International Nuclear Information System (INIS)

    Carre, F.; Fiorini, G.L.; Kupitz, J.; Depisch, F.; Hittner, D.

    2003-01-01

    Generation IV international forum (GIF) was initiated in 2000 by DOE (American department of energy) in order to promote nuclear energy in a long term view (2030). GIF has selected 6 concepts of reactors: 1) VHTR (very high temperature reactor system, 2) GHR (gas-cooled fast reactor system), 3) SFR (sodium-cooled fast reactor system, 4) SCWR (super-critical water-cooled reactor system), 5) LFR (lead-cooled fast reactor system), and 6) MFR (molten-salt reactor system). All these 6 reactor systems have been selected on criteria based on: - a better contribution to sustainable development (through their aptitude to produce hydrogen or other clean fuels, or to have a high energy conversion ratio...) - economic profitability, - safety and reliability, and - proliferation resistance. The 6 concepts of reactors are examined in the first article, the second article presents an overview of the results of the international project on innovative nuclear reactors and fuel cycles (INPRO) within IAEA. The project finished its first phase, called phase-IA. It has produced an outlook into the future role of nuclear energy and defined the need for innovation. The third article is dedicated to 2 international cooperations: MICANET and HTR-TN. The purpose of MICANET is to propose to the European Commission a research and development strategy in order to develop the assets of nuclear energy for the future. Future reactors are expected to be more multiple-purposes, more adaptable, safer than today, all these developments require funded and coordinated research programs. The aim of HTR-TN cooperation is to promote high temperature reactor systems, to develop them in a long term perspective and to define their limits in terms of burn-up and operating temperature. (A.C.)

  14. Status of advanced technologies for CANDU reactors

    International Nuclear Information System (INIS)

    Lipsett, J.J.

    1989-01-01

    The future development of the CANDU reactor is a continuation of a successful series of reactors, the most recent of which are nine CANDU 6 Mk 1* units and four Darlington units. There are three projects underway that continue the development of the CANDU reactor. These new design projects flow from the original reactor designs and are a natural progression of the CANDU 6 Mk 1, two units of which are operating successfully in Canada, one each in Argentina and Korea, with five more being built in Rumania. These new design projects are known as: CANDU 6 Mk 2, an improved version of CANDU 6 Mk 1; CANDU 3, a small, advanced version of the CANDU 6 Mk 1; CANDU 6 Mk 3, a series of advanced CANDU reactors. A short description of modified versions of CANDU reactors is given in this paper. 5 figs

  15. Optimal operating parameters of the reactor oscillator in the channel of 6.5/10 MW reactor; Odredjivanje optimalnih radnih tacaka za reaktorski oscilator u kanalu na reaktoru 6,5/10 MW

    Energy Technology Data Exchange (ETDEWEB)

    Lolic, B; Zecevic, V [The Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1961-07-01

    Operating conditions for the reactor oscillator in the central vertical experimental channel (VK5) in the RA reactor were studied during 1960. Channel VK5 was chosen because the sensitivity of the reactor is highest in this case. The central vertical experimental channel is placed in the center of the core and its bottom is placed 200 mm from the bottom of the reactor core. Diameter of the channel is is 110 mm and its length 5706 mm. During operation of the reactor oscillator with total modulation of the reactor power, it is very important to determine the oscillator operating point and the oscillation amplitude in such a way to avoid any change in reactor power level. Positive reactivity changes originating from oscillations of the samples should be compensated by the negative reactivity changes so that the effect should be nil. Operating points of the reactor oscillator are in the middle of the straight part of the figure showing the reactivity change dependent on the position of the absorber.

  16. Electrodeless, multi-megawatt reactor for room-temperature, lithium-6/deuterium nuclear reactions

    International Nuclear Information System (INIS)

    Drexler, J.

    1993-01-01

    This paper describes a reactor design to facilitate a room-temperature nuclear fusion/fission reaction to generate heat without generating unwanted neutrons, gamma rays, tritium, or other radioactive products. The room-temperature fusion/fission reaction involves the sequential triggering of billions of single-molecule, 6 LiD 'fusion energy pellets' distributed in lattices of a palladium ion accumulator that also acts as a catalyst to produce the molecules of 6 LiD from a solution comprising D 2 O, 6 LiOD with D 2 gas bubbling through it. The D 2 gas is the source of the negative deuterium ions in the 6 LiD molecules. The next step is to trigger a first nuclear fusion/fission reaction of some of the 6 LiD molecules, according to the well-known nuclear reaction: 6 Li + D → 2 4 He + 22.4 MeV. The highly energetic alpha particles ( 4 He nuclei) generated by this nuclear reaction within the palladium will cause shock and vibrations in the palladium lattices, leading to compression of other 6 LiD molecules and thereby triggering a second series of similar fusion/fission reactions, leading to a third series, and so on. The absorption of the kinetic energy in the palladium will, in turn, generate a continuous flow of heat into the heavy water carrier, which would be removed with a heat exchanger. (author)

  17. Roles of plasma neutron source reactor in development of fusion reactor engineering: Comparison with fission reactor engineering

    International Nuclear Information System (INIS)

    Hirayama, Shoichi; Kawabe, Takaya

    1995-01-01

    The history of development of fusion power reactor has come to a turning point, where the main research target is now shifting from the plasma heating and confinement physics toward the burning plasma physics and reactor engineering. Although the development of fusion reactor system is the first time for human beings, engineers have experience of development of fission power reactor. The common feature between them is that both are plants used for the generation of nuclear reactions for the production of energy, nucleon, and radiation on an industrial scale. By studying the history of the development of the fission reactor, one can find the existence of experimental neutron reactors including irradiation facilities for fission reactor materials. These research neutron reactors played very important roles in the development of fission power reactors. When one considers the strategy of development of fusion power reactors from the points of fusion reactor engineering, one finds that the fusion neutron source corresponds to the neutron reactor in fission reactor development. In this paper, the authors discuss the roles of the plasma-based neutron source reactors in the development of fusion reactor engineering, by comparing it with the neutron reactors in the history of fission power development, and make proposals for the strategy of the fusion reactor development. 21 refs., 6 figs

  18. Detection of gaseous heavy water leakage points in CANDU 6 pressurized heavy water reactors

    International Nuclear Information System (INIS)

    Park, T-K.; Jung, S-H.

    1996-01-01

    During reactor operation, the heavy water filled primary coolant system in a CANDU 6 Pressurized Heavy Water (PHWR) may leak through routine operations of the plant via components, mechanical joints, and during inadvertent operations etc. Early detection of leak points is therefore important to maintain plant safety and economy. There are many independent systems to monitor and recover heavy water leakage in a CANDU 6 PHWR. Methodology for early detection based on operating experience from these systems, is investigated in this paper. In addition, the four symptoms of D 2 O leakage, the associated process for clarifying and verifying the leakage, and the probable points of leakage are discussed. (author)

  19. Second meeting of the International Working Group on Advanced Technologies for Water Cooled Reactors, Helsinki, 6-9 June 1988

    International Nuclear Information System (INIS)

    1989-05-01

    The Second Meeting of the IAEA International Working Group on Advanced Technologies for Water Cooled Reactors (IWGATWR) was held in Helsinki, Finland, from 6-9 June 1988. The Summary Report (Part II) contains the papers which review the national programmes since the first meeting of IWGATWR in May 1987 in the field of Advanced Technologies for Water Cooled Reactors and other presentations at the Meeting. A separate abstract was prepared for each of these 12 papers presented at the meeting. Figs and tabs

  20. Prompt gamma neutron activation analysis facility at the RA-6 research reactor

    International Nuclear Information System (INIS)

    Sanchez, F. A.; Calzetta, O

    2004-01-01

    A prompt gamma neutron activation activation analysis facility was developed at the 500 kw thermal power RA-6 research reactor of the Bariloche Atomic Center, Argentina.This facility consist of a radial beam port with external positioning of the sample.The gamma radiation is reduced by a bismuth filter placed inside the extraction tube and the beam diameter is limited by a set of two collimators up to 5 cm.The neutron flux at the sample position is 7 10 6 n/cm 2 s with a Cadmium ratio of 20/1.The gamma detector is a 50 % efficiency type p HPGe rounded by a NaI(Tl) for Compton suppressioning.The gamma spectra is measured through 0 to 8.5 MeV.The background have counting rate of 350 cps without sample. In this work is shown the efficiency curve, the calculed sensibilities and the lower detection limits for B, Cd, Sm, Gd, H, Cl, Hg, Eu, Ti, Ag, Au, Mo. The RA-6's PGNAA facility is fully working, although the analytic capacity is under improvement [es

  1. Identity as Fleeting Fashion? Revealing the Background of Popularity Through Bosniaherzegovina’s Adoption of Bruce Lee

    Directory of Open Access Journals (Sweden)

    Alenka Bartulović

    2007-12-01

    Full Text Available This paper reflects on the background to popular research on identification processes in modern ethnology and cultural or social anthropology. By discussing themes closely connected to identity (national and popular culture, and the construction of Others, the author reveals that identity is not merely a redundant trend that researchers recklessly pursue, but that it reflects the need to reveal existing uncertainties and is an attempt to revise errors made to date, as well as lapses of the discipline we work in. The author primarily focuses on national identity and its situational transformations and intertwining with other existing identities. Bosnia-Herzegovina is placed at the center of interest. This theoretically oriented text concludes by analyzing the idea of erecting a monument to Bruce Lee in Mostar, which reveals the full complexity of identity processes around a world marked by intense and unique global and transnational currents.

  2. Monitoring the risk of loss of heat sink during plant shutdowns at Bruce Generating Station 'A'

    International Nuclear Information System (INIS)

    Krishnan, K.S.; Mancuso, F.; Vecchiarelli, D.

    1996-01-01

    A relatively simple loss of shutdown heat sink fault tree model has been developed and used during unit outages at Bruce Nuclear Generation Station 'A' to assess, from a risk and reliability perspective, alternative heat sink strategies and to aid in decisions on allowable outage configurations. The model is adjusted to reflect the various unit configurations planned during a specific outage, and identifies events and event combinations leading to loss of fuel cooling. The calculated failure frequencies are compared to the limits consistent with corporate and international public safety goals. The importance measures generated by the interrogation of the fault tree model for each outage configuration are also used to reschedule configurations with high fuel damage frequency later into the outage and to control the configurations with relatively high probability of fuel damage to short intervals at the most appropriate time into the outage. (author)

  3. Biodegradation of 2,4,6-trichlorophenol in a packed-bed biofilm reactor equipped with an internal net draft tube riser for aeration and liquid circulation

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-De Jesus, A.; Romano-Baez, F.J.; Leyva-Amezcua, L.; Juarez-Ramirez, C.; Ruiz-Ordaz, N. [Departamento de Ingenieria Bioquimica, Escuela Nacional de Ciencias Biologicas, IPN. Prol. Carpio y Plan de Ayala, Colonia Santo Tomas, s/n. CP 11340, Mexico, D.F. (Mexico); Galindez-Mayer, J. [Departamento de Ingenieria Bioquimica, Escuela Nacional de Ciencias Biologicas, IPN. Prol. Carpio y Plan de Ayala, Colonia Santo Tomas, s/n. CP 11340, Mexico, D.F. (Mexico)], E-mail: cmayer@encb.ipn.mx

    2009-01-30

    For the aerobic biodegradation of the fungicide and defoliant 2,4,6-trichlorophenol (2,4,6-TCP), a bench-scale packed-bed bioreactor equipped with a net draft tube riser for liquid circulation and oxygenation (PB-ALR) was constructed. To obtain a high packed-bed volume relative to the whole bioreactor volume, a high A{sub D}/A{sub R} ratio was used. Reactor's downcomer was packed with a porous support of volcanic stone fragments. PB-ALR hydrodynamics and oxygen mass transfer behavior was evaluated and compared to the observed behavior of the unpacked reactor operating as an internal airlift reactor (ALR). Overall gas holdup values {epsilon}{sub G}, and zonal oxygen mass transfer coefficients determined at various airflow rates in the PB-ALR, were higher than those obtained with the ALR. When comparing mixing time values obtained in both cases, a slight increment in mixing time was observed when reactor was operated as a PB-ALR. By using a mixed microbial community, the biofilm reactor was used to evaluate the aerobic biodegradation of 2,4,6-TCP. Three bacterial strains identified as Burkholderia sp., Burkholderia kururiensis and Stenotrophomonas sp. constituted the microbial consortium able to cometabolically degrade the 2,4,6-TCP, using phenol as primary substrate. This consortium removed 100% of phenol and near 99% of 2,4,6-TCP. Mineralization and dehalogenation of 2,4,6-TCP was evidenced by high COD removal efficiencies ({approx}95%), and by the stoichiometric release of chloride ions from the halogenated compound ({approx}80%). Finally, it was observed that the microbial consortium was also capable to metabolize 2,4,6-TCP without phenol as primary substrate, with high removal efficiencies (near 100% for 2,4,6-TCP, 92% for COD and 88% for chloride ions)

  4. 75 FR 36126 - Office of New Reactors; Proposed Revision to Standard Review Plan Section 13.6.1, Revision 1 on...

    Science.gov (United States)

    2010-06-24

    ... Standard Review Plan Section 13.6.1, Revision 1 on Physical Security--Combined License and Operating...), Section 13.6.1 on ``Physical Security--Combined License and Operating Reactors,'' (Agencywide Documents Access and Management System (ADAMS) Accession No. ML100350158). The Office of Nuclear Security and...

  5. Magnetite synthesis from ferrous iron solution at pH 6.8 in a continuous stirred tank reactor.

    Science.gov (United States)

    Mos, Yvonne M; Zorzano, Karin Bertens; Buisman, Cees J N; Weijma, Jan

    2018-04-01

    Partial oxidation of defined Fe 2+ solutions is a well-known method for magnetite synthesis in batch systems. The partial oxidation method could serve as basis for an iron removal process in drinking water production, yielding magnetite (Fe 3 O 4 ) as a compact and valuable product. As a first step toward such a process, a series of experiments was carried out, in which magnetite was synthesized from an Fe 2+ solution in a 2 L continuous stirred tank reactor (CSTR) at atmospheric pressure and 32 °C. In four experiments, elevating the pH from an initial value of 5.5 or 6.0 to a final value of 6.8, 7.0 or 7.5 caused green rust to form, eventually leading to magnetite. Formation of NH 4 + in the reactor indicated that NO 3 - and subsequently NO 2 - served as the oxidant. However, mass flow analysis revealed an influx of O 2 to the reactor. In a subsequent experiment, magnetite formation was achieved in the absence of added nitrate. In another experiment, seeding with magnetite particles led to additional magnetite precipitation without the need for a pH elevation step. Our results show, for the first time, that continuous magnetite formation from an Fe 2+ solution is possible under mild conditions, without the need for extensive addition of chemicals.

  6. Cobalt-60 production in CANDU power reactors

    International Nuclear Information System (INIS)

    Slack, J.; Norton, J.L.; Malkoske, G.R.

    2003-01-01

    therapy machines. Today the majority of the cancer therapy cobalt-60 sources used in the world are manufactured using material from the NRU reactor in Chalk River. The same technology that was used for producing cobalt-60 in a research reactor was then adapted and transferred for use in a CANDU power reactor. In the early 1970s, in co-operation with Ontario Power Generation (formerly Ontario Hydro), bulk cobalt-60 production was initiated in the four Pickering A CANDU reactors located east of Toronto. This was the first full scale production of millions of curies of cobalt-60 per year. As the demand and acceptance of sterilization of medical products grew, MDS Nordion expanded its bulk supply by installing the proprietary Canadian technology in additional CANDUs. Over the years MDS Nordion has partnered with CANDU reactor owners to produce cobalt-60 at various sites. CANDU reactors that have, or are still producing cobalt-60, include Pickering A, Pickering B, Gentilly 2, Embalse in Argentina, and Bruce B. In conclusion, the technology for cobalt-60 production in CANDU reactors, designed and developed by MDS Nordion and Atomic Energy of Canada, has been safely, economically and successfully employed in CANDU reactors with over 195 reactor years of production. Today over forty percent of the world's disposable medical supplies are made safer through sterilization using cobalt-60 sources from MDS Nordion. Over the past 40 years, MDS Nordion with its CANDU reactor owner partners, has safely and reliably shipped more than 500 million curies of cobalt-60 sources to customers around the world. MDS Nordion is presently adding three more CANDU power reactors to its supply chain. These three additional cobalt producing CANDU's will help supplement the ability of the health care industry to provide safe, sterile, medical disposable products to people around the world. As new applications for cobalt-60 are identified, and the demand for bulk cobalt-60 increases, MDS Nordion and AECL

  7. Reactor physics data for safety analysis of CANFLEX-NU CANDU-6 core

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Chang Joon; Suk, Ho Chun

    2001-08-01

    This report contains the reactor physics data for safety analysis of CANFLEX-NU fuel CANDU-6 core. First, the physics parameters for time-average core have been described, which include the channel power and maximum bundle power map, channel axial power shape and bundle burnup. And, next the data for fuel performance such as relative ring power distribution and bundle burnup conversion ratio are represented. The transition core data from 0 to 900 full power day are represented by 100 full power day interval. Also, the data for reactivity devices of time-average core and 300 full power day of transition core are given.

  8. Actualización del sistema SCADA y de control para los reactores MQ5 y MQ6 de la planta de Pinturas Condor, Sherwin Williams Ecuador

    Directory of Open Access Journals (Sweden)

    Jonathan Reinoso

    2013-12-01

    Full Text Available El presente documento describe la actualización del sistema SCADA para los reactores MQ5 y MQ6 de la planta de Pinturas Condor mediante el software Intouch y la actualización del sistema de control del reactor MQ5 implementado en un controlador lógico programable (PLC de marca SCHNEIDER, además de la arquitectura de control realizada en el proyecto. El sistema SCADA y de control de los reactores permiten la visualización y control de los datos y variables más relevantes durante las diferentes fases de producción de resinas en los reactores MQ5 y MQ6.

  9. Reactor of the XXI century

    International Nuclear Information System (INIS)

    Zhotabaev, Zh.R.; Solov'ev, Yu.A.

    2001-01-01

    The advantages of both molten salt reactors (MSR) and homogenous molten salt reactors (HMSR) are illuminated. It is noted that the MSR possess accident probability A=10 -6 1/reactor.years and the HMSR with integral configuration has A=10 -7 1/reactor.years. The methods for these reactors technological problems solution - tritium removal, salt melt circulation and capacity pick up - are discussed

  10. Criticality calculations of the HTR-10 pebble-bed reactor with SCALE6/CSAS6 and MCNP5

    International Nuclear Information System (INIS)

    Wang, Meng-Jen; Sheu, Rong-Jiun; Peir, Jinn-Jer; Liang, Jenq-Horng

    2014-01-01

    Highlights: • Comparisons of the HTR-10 criticality calculations with SCALE6/CSAS6 and MCNP5 were performed. • The DOUBLEHET unit-cell treatment provides the best k eff estimation among PBR criticality calculations using SCALE6. • The continuous-energy SCALE6 calculations present a non-negligible discrepancy with MCNP5 in three PBR cases. - Abstract: HTR-10 is a 10 MWt prototype pebble-bed reactor (PBR) that presents a doubly heterogeneous geometry for neutronics calculations. An appropriate unit-cell treatment for the associated fuel elements is vital for creating problem-dependent multigroup cross sections. Considering four unit-cell options for resonance self-shielding correction in SCALE6, a series of HTR-10 core models were established using the CSAS6 sequence to systematically investigate how they affected the computational accuracy and efficiency of PBR criticality calculations. Three core configurations, which ranged from simplified infinite lattices to a detailed geometry, were examined. Based on the same ENDF/B-VII.0 cross-section library, multigroup results were evaluated by comparing with continuous-energy SCALE6/CSAS6 and MCNP5 calculations. The comparison indicated that the INFHOMMEDIUM results overestimated the effective multiplication factor (k eff ) by about 2800 pcm, whereas the LATTICECELL and MULTIREGION treatments overestimated k eff values with similar biases at approximately 470–680 pcm. The DOUBLEHET results attained further improvement, reducing the k eff overestimation to approximately 280 pcm. The comparison yielded two unexpected problems from using SCALE6/CSAS6 in HTR-10 criticality calculations. In particular, the continuous-energy CSAS6 calculations in this study present a non-negligible discrepancy with MCNP5, potentially causing a k eff value overestimate of approximately 680 pcm. Notably, using a cell-weighted mixture instead of an explicit model of individual TRISO particles in the pebble fuel zone does not shorten the

  11. Development of the electron beam welding of the aluminium alloy 6061-T6 for the Jules Horowitz reactor

    International Nuclear Information System (INIS)

    Leblanc, Y.

    2013-01-01

    The aluminium alloy 6061-T6 has been selected for the construction of the Jules Horowitz's reactor vessel. This reactor vessel is pressurized and will be made through butt welding of ∼ 2 cm thick aluminium slabs. The electron beam welding process has been tested and qualified. It appears that this welding process allows: -) welding without pre-heating, -) vacuum welding, -) welding of 100% of the thickness in one passage, -) very low deforming welding process, -) very low density and very low volume of blow holes, -) weak ZAT (Thermal Affected Zones), and -) high reproducibility that permits automation. (A.C.)

  12. Dolomitized bryozoan bioherms from the Lower Silurian Manitoulin Formation, Bruce Peninsula, Ontario

    Energy Technology Data Exchange (ETDEWEB)

    Anastas, A S; Coniglo, M [Waterloo Univ., ON (Canada)

    1992-06-01

    Several small, previously undescribed bioherms are present in the shallow shelf dolostones of the Manitoulin Formation at the Cabot Head and Wingfield Basin localities in the northernmost portion of the Bruce Peninsula region of southern Ontario. The bioherms, commonly associated with carbonate tempestites, range from 0.3 to 1.0 m in height and 0.9 to 2.5 m in width and are composed of bafflestones-floatstones and minor bindstones. The chief components of the bioherms are dolomitized lime mud and branching bryozoans. Bioherm building by bryozoans, although common in the ancient record, represents a great divergence from the mostly accessory frame encrusting role of bryozoans in modern environments. Minor skeletal components of the bioherms include echinoderms, rugose and tabulate corals and brachiopods. Laminar encrusting bryozoans exist in the top 10 cm of one of the bioherms. Some of the bioherms show evidence of water agitation that may be the result of current action induced by storm or tidal processes. The occurrence of the bioherms stretches the already known Llandoverian reef complex on Manitoulin Island further to the south. The reason why these bioherms did not reach sizes comparable to large Llandoverian or Wenlockian reefs and did not make the shift to coral-stromaporoid community is probably related to a complex interaction of factors such as community development, bathymetry, clasticity and salinity. 41 refs., 4 figs.

  13. Probability safety assessment of the Kozloduy-5 and Kozloduy-6 reactors

    Energy Technology Data Exchange (ETDEWEB)

    Boyadzhiev, A; Manchev, B [Risk Engineering Ltd., Sofia (Bulgaria)

    1996-12-31

    A probability safety assessment (PSA) of Level 1 (assessment of plant failures leading to the determination of core damage frequency) has been carried out for the NPP Kozloduy Units 5 and 6 (reactors WWER-1000). The scope of the study includes all significant accident initiators including seismic (earthquake) and fire initiators. Event trees for all initiators and fault trees for front line systems, support systems and major safety systems have been built. A distribution of the different initiators has been established as follows: internal initiators - 85%, seismic initiators - 5%, fire initiators- 10%. The loss of offsite power was identified as main contributor from the internal initiators with frequency 1,1.10{sup -4}/y. It is concluded that the safety functions of WWER-1000 are adequately covered by the safety systems. 4 refs., 2 tabs.

  14. Small propulsion reactor design based on particle bed reactor concept

    International Nuclear Information System (INIS)

    Ludewig, H.; Lazareth, O.; Mughabghab, S.; Perkins, K.; Powell, J.R.

    1989-01-01

    In this paper Particle Bed Reactor (PBR) designs are discussed which use 233 U and /sup 242m/Am as fissile materials. A constant total power of 100MW is assumed for all reactors in this study. Three broad aspects of these reactors is discussed. First, possible reactor designs are developed, second physics calculations are outlined and discussed and third mass estimates of the various candidates reactors are made. It is concluded that reactors with a specific mass of 1 kg/MW can be envisioned of 233 U is used and approximately a quarter of this value can be achieved if /sup 242m/Am is used. If this power level is increased by increasing the power density lower specific mass values are achievable. The limit will be determined by uncertainties in the thermal-hydraulic analysis. 5 refs., 5 figs., 6 tabs

  15. Licensed reactor nuclear safety criteria applicable to DOE reactors

    International Nuclear Information System (INIS)

    1991-04-01

    The Department of Energy (DOE) Order DOE 5480.6, Safety of Department of Energy-Owned Nuclear Reactors, establishes reactor safety requirements to assure that reactors are sited, designed, constructed, modified, operated, maintained, and decommissioned in a manner that adequately protects health and safety and is in accordance with uniform standards, guides, and codes which are consistent with those applied to comparable licensed reactors. This document identifies nuclear safety criteria applied to NRC [Nuclear Regulatory Commission] licensed reactors. The titles of the chapters and sections of USNRC Regulatory Guide 1.70, Standard Format and Content of Safety Analysis Reports for Nuclear Power Plants, Rev. 3, are used as the format for compiling the NRC criteria applied to the various areas of nuclear safety addressed in a safety analysis report for a nuclear reactor. In each section the criteria are compiled in four groups: (1) Code of Federal Regulations, (2) US NRC Regulatory Guides, SRP Branch Technical Positions and Appendices, (3) Codes and Standards, and (4) Supplemental Information. The degree of application of these criteria to a DOE-owned reactor, consistent with their application to comparable licensed reactors, must be determined by the DOE and DOE contractor

  16. Fuel Fabrication and Nuclear Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Karpius, Peter Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-02-02

    The uranium from the enrichment plant is still in the form of UF6. UF6 is not suitable for use in a reactor due to its highly corrosive chemistry as well as its phase diagram. UF6 is converted into UO2 fuel pellets, which are in turn placed in fuel rods and assemblies. Reactor designs are variable in moderators, coolants, fuel, performance etc.The dream of energy ‘too-cheap to meter’ is no more, and now the nuclear power industry is pushing ahead with advanced reactor designs.

  17. Calculation of the flow distribution for the new core of the RA-6 reactor

    International Nuclear Information System (INIS)

    Garcia, J.C.; Delmastro, Dario F.

    2007-01-01

    In this work the pressure drop, the flow distribution, effective cooling flow rate and the velocity in the subchannels that cool fuel plates for the new core of RA-6 research reactor were calculated. These calculations were performed for a flow of 340 m 3 /hr and water temperatures of 12 C degrees, of 35 C degrees and 42 C degrees. The flow distribution was calculated without considering either safety factors or geometric changes. All the calculations were performed considering the flow as isothermal. (author) [es

  18. The dew point response of the annulus gas system of Bruce NGS A

    International Nuclear Information System (INIS)

    Kenchington, J.; Ellis, P.J.; Meranda, D.

    1983-01-01

    The dew point response of the Annulus Gas System in Bruce A, Units 1 and 2 has been modelled in order to alert the operator of the presence of heavy water and to estimate the leak rate into the annulus. The computer model can be easily adapted to determine the Annulus Gas System dew point response in any station. It models the complex arrangement of the system and the transportation of moisture through the annuli by a combination of plug flow and mixing of CO 2 and D 2 O vapor. It predicts the response of the dew point monitor for a range of specified leak rates and positions of a leaking channel in a string of channels. This model has been used to calculate the variation of dew point and rate of change of dew point with respect to time (t). It shows that there is a maximum in the rate of dew point change (dT/dt) with respect to the corresponding dew point (T). This maximum is unique for a given leak rate and channel position. It is independent of the starting time for the leak. The computer programme has been verified by an analytical solution for the model

  19. Safeguarding research reactors

    International Nuclear Information System (INIS)

    Powers, J.A.

    1983-03-01

    The report is organized in four sections, including the introduction. The second section contains a discussion of the characteristics and attributes of research reactors important to safeguards. In this section, research reactors are described according to their power level, if greater than 25 thermal megawatts, or according to each fuel type. This descriptive discussion includes both reactor and reactor fuel information of a generic nature, according to the following categories. 1. Research reactors with more than 25 megawatts thermal power, 2. Plate fuelled reactors, 3. Assembly fuelled reactors. 4. Research reactors fuelled with individual rods. 5. Disk fuelled reactors, and 6. Research reactors fuelled with aqueous homogeneous fuel. The third section consists of a brief discussion of general IAEA safeguards as they apply to research reactors. This section is based on IAEA safeguards implementation documents and technical reports that are used to establish Agency-State agreements and facility attachments. The fourth and last section describes inspection activities at research reactors necessary to meet Agency objectives. The scope of the activities extends to both pre and post inspection as well as the on-site inspection and includes the examination of records and reports relative to reactor operation and to receipts, shipments and certain internal transfers, periodic verification of fresh fuel, spent fuel and core fuel, activities related to containment and surveillance, and other selected activities, depending on the reactor

  20. Studies of a modular advanced stellarator reactor ASRA6C

    International Nuclear Information System (INIS)

    Boehme, G.; Jentzsch, K.; Komarek, P.; Maurer, W.; El-Guebaly, L.A.; Emmert, G.A.; Kulcinski, G.L.; Larsen, E.M.; Sanatarius, J.F.; Schawan, M.E.; Scharer, J.E.; Sviatoslavski, I.N.; Vogelsang, W.F.; Walstrom, P.L.; Wittenberg, L.J.; Grieger, G.; Harmeyer, E.; Herrnegger, F.; Kisslinger, J.; Rau, F.; Wobig, H.

    1987-05-01

    This study is directed towards the clarification of critical issues of advanced modular stellerator reactors exploiting the inherent potential of steady state operation, and is not a point design study of a reactor. Critical technology issues arise from the three-dimensional magnetic field structure. The first wall, blanket and shield are more complex than those of axi-symmetric systems, but this is eased at moderate to large aspect ratio typical of stellerators. Several blanket options have been studied and a thin blanket (21 cm) was the first choice for the design. Superconducting modular coils were investigated with respect to the conductor and mechanical supports. From the analysis of forces and stresses caused by the electromagnetic loads the coils are considered to be feasible, although shear stresses might pose a critical issue. Demountable intermagnetic support elements were designed for use at separation areas between the cryostat modules. A scheme for remote reactor maintenance was also developed. The plasma physics issues of different configurations were studied using extrapolations of transort behaviour and equilibrium from theory and present experiments. These studies indicate that the confinement and equilibrium behaviour is adequate for ignited operation at an average value of 5% beta. Impurities may pose a critical issue. Several impurity control operations were investigated; a pumped limiter configuration utilizing the 'ergodic layer' at the plasma edge was chosen for edge plasma and impurity control. A general conclusion of the study is that the modular stellerator configuration offers interesting prospects regarding the development towards steady-state reactors. (orig.)

  1. Studies of a modular advanced stellarator reactor ASRA6C

    International Nuclear Information System (INIS)

    Boehme, G.; El-Guebaly, L.A.; Emmert, G.A.; Grieger, G.; Harmeyer, E.; Herrnegger, F.; Huebener, J.; Jentzsch, K.; Kisslinger, J.; Komarek, P.; Kulcinski, G.L.; Larsen, E.M.; Maurer, W.; Rau, F.; Santarius, J.F.; Sawan, M.E.; Scharer, J.E.; Sviatoslavsky, I.N.; Vogelsang, W.F.; Walstrom, P.L.; Wittenberg, L.J.; Wobig, H.

    1987-06-01

    This study is directed towards the clarification of critical issues of advanced modular stellerator reactors exploiting the inherent potential of steady state operation, and is not a point design study of a reactor. Critical technology issues arise from the three-dimensional magnetic field structure. The first wall, blanket and shield are more complex than those of axi-symmetric systems, but this is eased at moderate to large aspect ratio typical of stellarators. Several blanket options have been studied and a thin blanket (21 cm) was the first choice for the design. Superconducting modular coils were investigated with respect to the conductor and mechanical supports. From the analysis of forces and stresses caused by the electromagnetic loads the coils are considered to be feasible, although shear stresses might pose a critical issue. Demountable intermagnetic support elements were designed for use at separation areas between the cryostat modules. A scheme for remote reactor maintenance was also developed. The plasma physics issues of different configurations were studied using extrapolations of transport behaviour and equilibrium from theory and present experiments. These studies indicate that the confinement and equilibrium behaviour is adequate for ignited operation at an average value of 5% beta. Impurities may pose a critical issue. Several impurity control operations were investigated; a pumped limiter configuration utilizing the 'ergodic layer' at the plasma edge was chosen for edge plasma and impurity control. A general conclusion of the study is that the modular stellerator configuration offers interesting prospects regarding the development towards steady-state reactors. (orig.) [de

  2. Adjusting to new realities. IAEO meeting on fuel cycle and reactor strategies, June 3-6, 1997 in Vienna

    International Nuclear Information System (INIS)

    Jelinek-Fink, P.

    1997-01-01

    The IAEA, in co-operation with the European Commission, the Nuclear Energy Agency of the OECD and the Uranium Institute, organized an international symposium to discuss the 'new realities' in the nuclear fuel cycle with special emphasis on plutonium management. The symposium covered all aspects of the fuel cycle in six sessions: Global Energy Outlook; Present Status and Immediate Prospects of Plutonium Management; Future Fuel Cycle and Reactor Strategies; Safety, Health and Environmental Implications of the Different Fuel Cycles; Non-Proliferation and Safeguards Aspects; and International Co-operation. The Symposium took place in Vienna, 3-6 June 1997. About 300 participants from 41 countries and 4 international organizations attended. The Symposium gave a comprehensive overview on the present situation of the fuel cycle and the expected developments up to 2050. During this period nuclear energy will continue to be dominated by Thermal Reactors; Fast Reactors will be introduced slowly after 2030. In general, an evolutionary and not a revolutionary process is expected. (orig.) [de

  3. Development of U6Fe-Al dispersions for the use of LEU in research and test reactors

    International Nuclear Information System (INIS)

    Nazare, S.

    1983-01-01

    For some time now, efforts are being made to develop fuel dispersions that would permit the use of low (approx. 20% 235-U) enriched uranium (LEU) instead of the currently used highly (approx. 93% 235-U) enriched uranium (HEU) in research and test reactors. Since penalties in the performance of the reactor have to be avoided, the 235-U content in the dispersion has at least to be retained at current levels. On account of their high U-densities, the major development effort has been focussed on the uranium silicides (U 3 Si, U 3 Si(Al), and U 3 Si 2 -based dispersions). With silicides as dispersants, it is possible to fabricate fuel element plates with U-densities in the dispersion of about 6.0 gU/cm 3 . In comparison to the silicides, the U 6 Fe-phase offers several advantages namely: higher U-density (approx. 17.0 gU/cm 3 ); relative ease of formation compared to U 3 Si; possible advantages with regard to reprocessing of the spent fuel due to the absence of silicon. The studies outlined here were performed with a view to investigating the preparation, reaction behavior and dimensional stability after heat treatment of U 6 Fe-Al dispersions

  4. Development of U6Fe-Al dispersions for the use of LEU in research and test reactors

    International Nuclear Information System (INIS)

    Nazare, S.

    1983-01-01

    For some time now, efforts are being made to develop fuel dispersions that would permit the use of low (∼ 20% 235-U) enriched uranium (LEU) instead of the currently used highly (∼ 93% 235-U) enriched uranium (HEU) in research and test reactors. Since penalties in the performance of the reactor have to be avoided, the 235-U content in the dispersion has at least to be retained at current levels. On account of their high U-densities, the major development effort has been focussed on the uranium silicides [U 3 Si, U 3 Si(Al), and U 3 Si 2 - based dispersions. With silicides as dispersants, it is possible to fabricate fuel element plates with U-densities in the dispersion of about 6.0 g U/cm 3 . In comparison to the silicides, the U 6 Fe-phase offers several advantages namely: - higher U-density (∼ 17.0 g U/cm 3 ); - relative ease of formation compared to U 3 Si; - possible advantages with regard to reprocessing of the spent fuel due to the absence of silicon. The studies outlined here were therefore performed with a view to investigating the preparation, reaction behaviour and dimensional stability after heat treatment of U 6 Fe-Al dispersions

  5. Application of SCALE 6.1 MAVRIC Sequence for Activation Calculation in Reactor Primary Shield Concrete

    International Nuclear Information System (INIS)

    Kim, Yong IL

    2014-01-01

    Activation calculation requires flux information at desired location and reaction cross sections for the constituent elements to obtain production rate of activation products. Generally it is not an easy task to obtain fluxes or reaction rates with low uncertainties in a reasonable time for deep penetration problems by using standard Monte Carlo methods. The MAVRIC (Monaco with Automated Variance Reduction using Importance Calculations) sequence in SCALE 6.1 code package is intended to perform radiation transport on problems that are too challenging for standard, unbiased Monte Carlo methods. And the SCALE code system provides plenty of ENDF reaction types enough to consider almost all activation reactions in the nuclear reactor materials. To evaluate the activation of the important isotopes in primary shield, SCALE 6.1 MAVRIC sequence has been utilized for the KSNP reactor model and the calculated results are compared to the isotopic activity concentration of related standard. Related to the planning for decommission, the activation products in concrete primary shield such as Fe-55, Co-60, Ba-133, Eu-152, and Eu-154 are identified as important elements according to the comparisons with related standard for exemption. In this study, reference data are used for the concrete compositions in the activation calculation to see the applicability of MAVRIC code to the evaluation of activation inventory in the concrete primary shield. The composition data of trace elements as shown in Table 1 are obtained from various US power plant sites and accordingly they have large variations in quantity due to the characteristics of concrete composition. In practical estimation of activation radioactivity for a specific plant related to decommissioning, rigorous chemical analysis of concrete samples of the plant would first have to be performed to get exact information for compositions of concrete. Considering the capability of solving deep penetration transport problems and richness

  6. Research reactors in Argentina

    International Nuclear Information System (INIS)

    Carlos Ruben Calabrese

    1999-01-01

    Argentine Nuclear Development started in early fifties. In 1957, it was decided to built the first a research reactor. RA-1 reactor (120 kw, today licensed to work at 40 kW) started operation in January 1958. Originally RA-1 was an Argonaut (American design) reactor. In early sixties, the RA-1 core was changed. Fuel rods (20% enrichment) was introduced instead the old Argonaut core design. For that reason, a critical facility named RA-0 was built. After that, the RA-3 project started, to build a multipurpose 5 MW nuclear reactor MTR pool type, to produce radioisotopes and research. For that reason and to define the characteristics of the RA-3 core, another critical facility was built, RA-2. Initially RA-3 was a 90 % enriched fuel reactor, and started operation in 1967. When Atucha I NPP project started, a German design Power Reactor, a small homogeneous reactor was donated by the German Government to Argentina (1969). This was RA-4 reactor (20% enrichment, 1W). In 1982, RA-6 pool reactor achieved criticality. This is a 500 kW reactor with 90% enriched MTR fuel elements. In 1990, RA-3 started to operate fueled by 20% enriched fuel. In 1997, the RA-8 (multipurpose critical facility located at Pilcaniyeu) started to operate. RA-3 reactor is the most important CNEA reactor for Argentine Research Reactors development. It is the first in a succession of Argentine MTR reactors built by CNEA (and INVAP SE ) in Argentina and other countries: RA-6 (500 kW, Bariloche-Argentina), RP-10 (10MW, Peru), NUR (500 kW, Algeria), MPR (22 MW, Egypt). The experience of Argentinian industry permits to compete with foreign developed countries as supplier of research reactors. Today, CNEA has six research reactors whose activities have a range from education and promotion of nuclear activity, to radioisotope production. For more than forty years, Argentine Research Reactors are working. The experience of Argentine is important, and argentine firms are able to compete in the design and

  7. Research of heat releasing element of an active zone of gaseous nuclear reactor with pumped through nuclear fuel - uranium hexafluoride (UF6)

    International Nuclear Information System (INIS)

    Batyrbekov, G.; Batyrbekov, E.; Belyakova, E.; Kunakov, S.; Koltyshev, S.

    1996-01-01

    The purpose of the offered project is learning physics and substantiation of possibility of creation gaseous nuclear reactor with pumped through nuclear fuel-hexafluoride of uranium (Uf6).Main problems of this work are'. Determination of physic-chemical, spectral and optical properties of non-equilibrium nuclear - excited plasma of hexafluoride of uranium and its mixtures with other gases. Research of gas dynamics of laminar, non-mixing two-layer current of gases of hexafluoride of uranium and helium at availability and absence of internal energy release in hexafluoride of uranium with the purpose to determinate a possibility of isolation of hexafluoride of uranium from walls by inert helium. Creation and research of gaseous heat releasing element with pumped through fuel Uf6 in an active zone of research nuclear WWR-K reactor. Objects of a research: Non-equilibrium nuclear - excited plasma of hexafluoride of uranium and its mixtures with other gases. With use of specially created ampoules will come true in-reactor probe and spectral diagnostics of plasma. Calculations of kinetics with the account of main elementary processes proceeding in it, will be carried out. Two-layer non-mixed streams of hexafluoride of uranium and helium at availability and absence of internal energy release. Conditions of obtaining and characteristics of such streams will be investigated. Gaseous heat releasing element with pumped through fuel - Uf6 in an active zone of nuclear WWR-K reactor

  8. Neutron transport. Physics and calculation of nuclear reactors with applications to pressurized water reactors and fast neutron reactors. 2 ed.

    International Nuclear Information System (INIS)

    Bussac, J.; Reuss, P.

    1985-01-01

    This book presents the main physical bases of neutron theory and nuclear reactor calculation. 1) Interactions of neutrons with matter and basic principles of neutron transport; 2) Neutron transport in homogeneous medium and the neutron field: kinetic behaviour, slowing-down, resonance absorption, diffusion equation, processing methods; 3) Theory of a reactor constituted with homogeneous zones: critical condition, kinetics, separation of variables, calculation and neutron balance of the fundamental mode, one-group and multigroup theories; 4) Study of heterogeneous cell lattices: fast fission factor, resonance absorption, thermal output factor, diffusion coefficient, computer codes; 5) Operation and control of reactors: perturbation theory, reactivity, fuel properties evolution, poisoning by fission products, calculation of a reactor and fuel management; 6) Study of some types of reactors: PWR and fast breeder reactors, the main reactor types of the present French program [fr

  9. Impact of proposed research reactor standards on reactor operation

    Energy Technology Data Exchange (ETDEWEB)

    Ringle, J C; Johnson, A G; Anderson, T V [Oregon State University (United States)

    1974-07-01

    A Standards Committee on Operation of Research Reactors, (ANS-15), sponsored by the American Nuclear Society, was organized in June 1971. Its purpose is to develop, prepare, and maintain standards for the design, construction, operation, maintenance, and decommissioning of nuclear reactors intended for research and training. Of the 15 original members, six were directly associated with operating TRIGA facilities. This committee developed a standard for the Development of Technical Specifications for Research Reactors (ANS-15.1), the revised draft of which was submitted to ANSI for review in May of 1973. The Committee then identified 10 other critical areas for standards development. Nine of these, along with ANS-15.1, are of direct interest to TRIGA owners and operators. The Committee was divided into subcommittees to work on these areas. These nine areas involve proposed standards for research reactors concerning: 1. Records and Reports (ANS-15.3) 2. Selection and Training of Personnel (ANS-15.4) 3. Effluent Monitoring (ANS-15.5) 4. Review of Experiments (ANS-15.6) 5. Siting (ANS-15.7) 6. Quality Assurance Program Guidance and Requirements (ANS-15.8) 7. Restrictions on Radioactive Effluents (ANS-15.9) 8. Decommissioning (ANS-15.10) 9. Radiological Control and Safety (ANS-15.11). The present status of each of these standards will be presented, along with their potential impact on TRIGA reactor operation. (author)

  10. Impact of proposed research reactor standards on reactor operation

    International Nuclear Information System (INIS)

    Ringle, J.C.; Johnson, A.G.; Anderson, T.V.

    1974-01-01

    A Standards Committee on Operation of Research Reactors, (ANS-15), sponsored by the American Nuclear Society, was organized in June 1971. Its purpose is to develop, prepare, and maintain standards for the design, construction, operation, maintenance, and decommissioning of nuclear reactors intended for research and training. Of the 15 original members, six were directly associated with operating TRIGA facilities. This committee developed a standard for the Development of Technical Specifications for Research Reactors (ANS-15.1), the revised draft of which was submitted to ANSI for review in May of 1973. The Committee then identified 10 other critical areas for standards development. Nine of these, along with ANS-15.1, are of direct interest to TRIGA owners and operators. The Committee was divided into subcommittees to work on these areas. These nine areas involve proposed standards for research reactors concerning: 1. Records and Reports (ANS-15.3) 2. Selection and Training of Personnel (ANS-15.4) 3. Effluent Monitoring (ANS-15.5) 4. Review of Experiments (ANS-15.6) 5. Siting (ANS-15.7) 6. Quality Assurance Program Guidance and Requirements (ANS-15.8) 7. Restrictions on Radioactive Effluents (ANS-15.9) 8. Decommissioning (ANS-15.10) 9. Radiological Control and Safety (ANS-15.11). The present status of each of these standards will be presented, along with their potential impact on TRIGA reactor operation. (author)

  11. Dose rate in the reactor room and environment during maintenance in fusion reactors

    International Nuclear Information System (INIS)

    Maki, Koichi; Satoh, Satoshi; Takatsu, Hideyuki; Seki, Yasushi

    1995-01-01

    According to the International Thermonuclear Experimental Reactor (ITER) conceptual design activity, after reactor shutdown, damaged segments are pulled up from the reactor and hung from the reactor room ceiling by a remote handling device. The dose rate in the reactor room and the environment is estimated for this situation, and the following results are obtained. First, the dose rate in the room is > 10 8 μSv/h. Since this dose rate is 10 7 times greater than the biological radiation shielding design limit of 25 μSv/h, workers cannot enter the room. Second, lenses and optical fiber composed of glass that is radiation resistant up to 10 6 Gy would be damaged after <100 h near the segment, and devices using semiconductors could not work after several hours or so in the aforementioned dose-rate conditions. Third, during suspension of one blanket segment from the ceiling, the dose rate in the site boundary can be reduced by one order by a 23-cm-thicker reactor building roof. To reduce dose rate in public exposure to a value that is less than one-tenth of the public exposure radiation shielding design limit of 100 μSv/yr, the distance of the site boundary from the reactor must be greater than 200 m for a reactor building with a 160-cm-thick concrete roof. 9 refs., 6 figs., 2 tabs

  12. Supercritical Water Reactors

    International Nuclear Information System (INIS)

    Bouchter, J.C.; Dufour, P.; Guidez, J.; Latge, C.; Renault, C.; Rimpault, G.

    2014-01-01

    The supercritical water reactor (SCWR) is one of the 6 concepts selected for the 4. generation of nuclear reactors. SCWR is a new concept, it is an attempt to optimize boiling water reactors by using the main advantages of supercritical water: only liquid phase and a high calorific capacity. The SCWR requires very high temperatures (over 375 C degrees) and very high pressures (over 22.1 MPa) to operate which allows a high conversion yield (44% instead of 33% for a PWR). Low volumes of coolant are necessary which makes the neutron spectrum shift towards higher energies and it is then possible to consider fast reactors operating with supercritical water. The main drawbacks of supercritical water is the necessity to use very high pressures which has important constraints on the reactor design, its physical properties (density, calorific capacity) that vary strongly with temperatures and pressures and its very high corrosiveness. The feasibility of the concept is not yet assured in terms of adequate materials that resist to corrosion, reactor stability, reactor safety, and reactor behaviour in accidental situations. (A.C.)

  13. The case for new nuclear

    International Nuclear Information System (INIS)

    Luxat, J.C.

    2013-01-01

    Over a 22 year period from 1971 to 1993 a total of 20 reactor units were brought into service - an average of approximately one unit per year. Ontario Hydro constructed the four-unit Pickering A station, four units at Bruce A, four units at Pickering B, four units at Bruce B and four units at Darlington during this period. This represents a capacity of nearly 14,000 MW, as shown in Figure 1. During this period there was a large increase in industrial capacity in Ontario, particularly in manufacturing, driven in large measure by the incentives offered by low electricity prices, skilled workers and a good health care system. Subsequently in the mid-1990's the Pickering A and Bruce A units were laid up and maintenance efforts were focused on the Pickering B, Bruce B and Darlington stations. Two of the four units at Pickering A were returned to service in the early 2000's and the four units of Bruce A were returned to service with two units being refurbished. By 2010 nuclear capacity in the province had returned to 12,800 MW. The Ontario Long Term Energy Plan (LTEP) announced at the beginning of December does not include new build nuclear but does include refurbishment of the Darlington station as well as two units at Bruce A and four units at Bruce B. The six units at Pickering will be shut down by 2020. As shown in Figure 1, this will reduce the nuclear capacity from the current 12,800 MW to 8000 MW when the Pickering A and B units are removed from service in 2020 and the refurbishment of Darlington and Bruce units proceeds starting in 2016 and projected to complete by 2031. This will be the lowest nuclear generating capacity in the province since 1985. (author)

  14. Tight fitting garter springs-MODAR

    Energy Technology Data Exchange (ETDEWEB)

    Kazimer, D. [Bruce Power, Tiverton, Ontario (Canada)

    2011-07-01

    Annulus spacers are used in CANDU reactors to maintain the annular gap between two tubes - an inner pressure tube (PT) and the outer calandria tube (CT). Typically four annulus spacers are used in one fuel channel assembly, each at a specified axial position. Bruce Unit 8 and many other CANDU units were constructed with tight-fitting garter springs (TFGS). The TFGS were not designed to be detected or relocated by the conventional tool, Spacer Location And Repositioning (SLAR) processes. Due to non-optimal 'As Left' construction locations for the Bruce Unit 8 TFGS, PT/CT contact has been predicted to occur well prior to its End of Life (EOL). Bruce Power entered a Project with AECL-CRL to design, manufacture and test and implement a new tooling system that would detect and reposition tight fitting annulus spacers. (author)

  15. Steps to Advanced CANDU 600

    International Nuclear Information System (INIS)

    Oh, Yongshick; Brooks, G. L.

    1988-01-01

    The CANDU nuclear power system was developed from merging of AECL heavy water reactor technology with Ontario Hydro electrical power station expertise. The original four units of Ontario Hydro's Pickering Generating Station are the first full-scale commercial application of the CANDU system. AECL and Ontario Hydro then moved to the next evolutionary step, a more advanced larger scale design for four units at the Bruce Generating Station. CANDU 600 followed as a single unit nuclear electric power station design derived from an amalgam of features of the multiple unit Pickering and Bruce designs. The design of the CANDU 600 nuclear steam supply system is based on the Pickering design with improvements derived from the Bruce design. For example, most CANDU 600 auxiliary systems are based on Bruce systems, whereas the fuel handling system is based on the Pickering system. Four CANDU 600 units are in operation, and five are under construction in Romania. For the additional four units at Pickering Generating Station 'B', Ontario Hydro selected a replica of the Pickering 'A' design with limited design changes to maintain a high level of standardization across all eight units. Ontario Hydro applied a similar policy for the additional four units at Bruce Generating Station 'B'. For the four unit Darlington station, Ontario Hydro selected a design based on Bruce with improvements derived from operating experience, the CANDU 600 design and development programs

  16. CANDU-PHW fuel channel replacement experience

    International Nuclear Information System (INIS)

    Dunn, J.T.; Kakaria, B.K.

    1982-09-01

    One of the main characteristics of the CANDU pressurized heavy water reactor is the use of pressure tubes rather than one large pressure vessel to contain the fuel and coolant. This provides an inherent design capability to permit their replacement in an expeditious manner, without seriously affecting the high capacity factors of the reactor units. Of th eight Ontario Hydro commercial nuclear generating units, the lifetime performance places seven of them (including two that have had some of their fuel channels replaced), in the top ten positions in the world's large nuclear-electric unit performance ranking. Pressure tube cracks in the rolled joint region have resulted in 70 fuel channels being replaced in three reactor units, the latest being at the Bruce Nuclear Generating Station 'A', Unit 2 in February 1982. The rolled joint design and rolling procedures have been modified to eliminate this problem on CANDU units subsequent to Bruce 'A'. This paper describes the CANDU pressure tube performance history and expectations, and the tooling and procedures used to carry out the fuel channel replacement

  17. A preliminary neutronic evaluation of the high temperature gas-cooled test reactor HTR-10 using the scale 6.0 code

    International Nuclear Information System (INIS)

    Sousa, Romulo V.; Fortini, Angela; Pereira, Claubia; Carvalho, Fernando R. de; Oliveira, Arno H.

    2013-01-01

    The High Temperature Gas-cooled Test Reactor HTR-10 is a 10 MW modular pebble bed type reactor, which core is filled with 27,000 spherical fuel elements, e.g. TRISO coated particles. This reactor was built by the Institute of Nuclear Energy Technology (INET), Tsinghua University, China, and its first criticality was attained on December 1, 2000. The main objectives of the HTR-10 are to verify and demonstrate the technical and safety features of the modular HTGR (High Temperature Gas-cooled Reactor) and to establish an experimental base for developing nuclear process heat applications. In this work, using the Standardized Computer Analysis for Licensing Evaluation (SCALE) 6.0, a nuclear code developed by Oak Ridge National Laboratory (ORNL), the HTR-10 first critical core is modeled by the DEN/UFMG. The K eff was obtained and compared with the reference value obtained by the Idaho National Laboratory. The result presents good agreement with experimental value. The goal is to validate the DEN/UFMG model to be applied in transmutation studies changing the fuel. (author)

  18. Volume reduction/solidification of liquid radioactive waste using bitumen at Ontario Hydro's Bruce Nuclear Generating Station 'A'

    International Nuclear Information System (INIS)

    Day, J.E.; Baker, R.L.

    1995-01-01

    Ontario Hydro at the Bruce Nuclear Generating Station 'A' has undertaken a program to render the station's liquid radioactive waste suitable for discharge to Lake Huron by removing sufficient radiological and chemical contaminants to satisfy regulatory requirements for emissions. The system will remove radionuclide and chemical contaminants from five different plant waste streams. The contaminants will be immobilized and stored at on-site radioactive waste storage facilities and the purified streams will be discharged. The discharge targets established by Ontario Hydro are set well below the limits established by the Ontario Ministry of Environment (MOE) and are based on the Best Available Technology Economically Achievable Approach (B.A.T.E.A.). ADTECHS Corporation has been selected by Ontario Hydro to provide volume reduction/solidification technology for one of the five waste streams. The system will dry and immobilize the contaminants from a liquid waste stream in emulsified asphalt using thin film evaporation technology

  19. A calculational procedure for neutronic and depletion analysis of Molten-Salt reactors based on SCALE6/TRITON

    International Nuclear Information System (INIS)

    Sheu, R.J.; Chang, J.S.; Liu, Y.-W. H.

    2011-01-01

    Molten-Salt Reactors (MSRs) represent one of the selected categories in the GEN-IV program. This type of reactor is distinguished by the use of liquid fuel circulating in and out of the core, which makes it possible for online refueling and salt processing. However, this operation characteristic also complicates the modeling and simulation of reactor core behaviour using conventional neutronic codes. The TRITON sequence in the SCALE6 code system has been designed to provide the combined capabilities of problem-dependent cross-section processing, rigorous treatment of neutron transport, and coupled with the ORIGEN-S depletion calculations. In order to accommodate the simulation of dynamic refueling and processing scheme, an in-house program REFRESH together with a run script are developed for carrying out a series of stepwise TRITON calculations, that makes the work of analyzing the neutronic properties and performance of a MSR core design easier. As a demonstration and cross check, we have applied this method to reexamine the conceptual design of Molten Salt Actinide Recycler & Transmuter (MOSART). This paper summarizes the development of the method and preliminary results of its application on MOSART. (author)

  20. Top of tubesheet cracking in Bruce A NGS steam generator tubing - recent experience

    International Nuclear Information System (INIS)

    Clark, M.A.; Lepik, O.; Mirzai, M.; Thompson, I.

    1998-01-01

    During the Bruce A Nuclear Generating Station (BNGS-A) Unit 1 1997 planned outage, a dew point search method identified a leak in one steam generator(SG) tube. Subsequently, the tube was inspected with all available eddy current probes and removed for examination. The initial inspection results and metallurgical examination of the removed tube confirmed that the leak was due to intergranular attack/stress corrosion cracking (IGA/SCC) emanating from the secondary side of the tube at the top of the tubesheet location. Subsequently, eddy current and ultrasonic indications were found at the top of the tubesheet of other Alloy 600 SG tubes. To investigate the source of the indications and to validate the inspection probes, sections of 40 tubes with various levels of damage were removed. The metallurgical examination of the removed sections showed that both secondary side and primary side initiated, circumferential, stress corrosion cracking and intergranular attack occurred in the BNGS-A SG tubing. Significant degradation from both mechanisms was found, invariably located in the roll transition region of the top expansion joint between the tube and the tubesheet on the hot leg (304 degrees C) side of the tube. Various aspects of the failures and tube examinations are presented in this paper, including presentation of the cracking morphology, measured crack size distributions, and discussion of some factors possibly affecting the cracking. (author)

  1. Thermohydraulic calculations in rectangular channels for RA-6 type reactors with transition regime

    International Nuclear Information System (INIS)

    Sillin, N; Vertullo, A.; Masson, V.; Hilal, R

    2009-01-01

    In August 2000 and within the framework of the RA-6 core conversion from high to low enrichment (20%), a preliminary analysis was performed to evaluate the maximum power that the reactor could operate with the new kernel without makeing substantial changes. This meant keeping intact, for example, the concrete shield of the pool and the nucleus inlet and outlet pipes embedded in the walls. Preliminary results indicated that for these boundary conditions a maximum power of about 3 MWt could be achieved. In August 2005 the project was resumed and new calculations performed taking as a starting point the ECBE plate fuel element(U3O8-Al). A core was developed with cooling channle widths of 2.6 mm for the control fuel elements and 2.7 mm for standard fuel elements. The thermo-hydraulic calculation puts in evidence that coolant flow into the core was in the transitional regime for the vast majority of configurations. While TERMIC code, used for thermo-hydraulic design, has been extensively tested and validated for use in research reactors under turbulent and laminar flows, this is not so for transition conditions. The transition regime is strongly dependent on conditions such as flow inlet characteristics, channel geometry, etc.. and therefore there are no reliable correlations for general use. For this reason we found it convenient to carry out experiments simulating the working conditions in order to adjust the code results with experimental data. In the present work we show the experimental results, the simulation of the experiences using the TERMIC code, and the adjustments made to the correlations used by the code so that it can be applied to the thermo-hydraulic design of the new core. [es

  2. Study on the technical feasibility of Fission-Track dating at two irradiation positions of the RA-6 research reactor

    International Nuclear Information System (INIS)

    Dorval, Eric

    2005-01-01

    The method of Fission-Track dating is based upon the detection of the damage caused by fission fragments from the Uranium contained in geological samples.In order to determine the age of a sample, both the amount of spontaneous fissions occurred and the Uranium concentration must be known.The latter requires the irradiation of the samples inside a reactor with a well-thermalized flux, so that fissions are induced over 235 U targets only. Therefore, the Uranium concentration may be determined.The main inconvenient presented by the irradiation sites at the RA-6 MTR-type reactor is that neutron flux is not completely thermal there, which means that fissions due to epithermal and fast neutrons will not be negligible.In the same way, tracks due to fissions of 238 U and 232 Th will be detected. In order to know the corrections that must be applied to those measurements performed in this reactor, it is necessary to characterize fast flux.Because of it, this laboratory's gamma spectrometry equipment had to be calibrated. After that, several activation detectors were irradiated and results were analyzed. Finally, it was determined that it is feasible to Fission-Track date at the I6 position. However, limitations associated to this method were analyzed for the values of flux measured in the different sites

  3. First TREAT [Transient Reactor Test Facility] transient overpower tests on U-Pu-Zr fuel: M5 and M6

    International Nuclear Information System (INIS)

    Robinson, W.R.; Bauer, T.H.; Wright, A.E.; Rhodes, E.A.; Stanford, G.S.; Klickman, A.E.

    1987-01-01

    Transient Reactor Test Facility (TREAT) tests M5 and M6 were the first transient overpower (TOP) tests of the margin to cladding breach and prefailure elongation of metallic U-Pu-Zr ternary fuel, the reference fuel of the Integral Fast Reactor concept. Similar tests on U-Fs fueled EBR-II driver pins were previously performed and reported [1,2]. Results from these earlier tests indicated a margin to failure of about 4 times nominal power and significant axial elongation prior to failure, a feature that was very pronounced at low burnups. While these two fuel types are similar in many respects, the ternary alloy exhibits a much more complex physical structure and is typically irradiated at much higher temperatures. Thus, a prime motivation for performing M5 and M6 was to compare the safety related fuel performance characteristics of U-Fs and U-Pu-Zr. This report described conditions, results, and conclusions of testing of these fuel types

  4. The JASON reactor at the Royal Naval College: Silver Jubilee 6th November 1987

    International Nuclear Information System (INIS)

    Lakey, J.R.A.; Roust, C.B.

    1988-01-01

    The 10 kW Research and Training Reactor Jason has been used at the Royal Naval College for 25 years in support of the Naval Nuclear Submarine Propulsion Programme. The principal features of Jason, relevant to its training role are given, along with the specifications of Jason, instrumentation, maintenance and operational experience. The educational role of the reactor is described with respect to the Nuclear Reactor Course, Nuclear Advanced Course, and the Nuclear Radiation Protection Course. Future developments in operator training, advantages of the low power reactor, quality control of education and training, and research and development, are also discussed. (U.K.)

  5. Preparation of a criticality benchmark based on experiments performed at the RA-6 reactor

    International Nuclear Information System (INIS)

    Bazzana, S.; Blaumann, H; Marquez Damian, J.I

    2009-01-01

    The operation and fuel management of a reactor uses neutronic modeling to predict its behavior in operational and accidental conditions. This modeling uses computational tools and nuclear data that must be contrasted against benchmark experiments to ensure its accuracy. These benchmarks have to be simple enough to be possible to model with the desired computer code and have quantified and bound uncertainties. The start-up of the RA-6 reactor, final stage of the conversion and renewal project, allowed us to obtain experimental results with fresh fuel. In this condition the material composition of the fuel elements is precisely known, which contributes to a more precise modeling of the critical condition. These experimental results are useful to evaluate the precision of the models used to design the core, based on U 3 Si 2 and cadmium wires as burnable poisons, for which no data was previously available. The analysis of this information can be used to validate models for the analysis of similar configurations, which is necessary to follow the operational history of the reactor and perform fuel management. The analysis of the results and the generation of the model were done following the methodology established by International Criticality Safety Benchmark Evaluation Project, which gathers and analyzes experimental data for critical systems. The results were very satisfactory resulting on a value for the multiplication factor of the model of 1.0000 ± 0.0044, and a calculated value of 0.9980 ± 0.0001 using MCNP 5 and ENDF/B-VI. The utilization of as-built dimensions and compositions, and the sensitivity analysis allowed us to review the design calculations and analyze their precision, accuracy and error compensation. [es

  6. Peak power factor determination of the RA-6 Argentinean Research Reactor using measurement-calculations correlations

    International Nuclear Information System (INIS)

    Sanchez, F. A.; Blaumann, H.; Lopasso, E.; Longhino, J

    2009-01-01

    The maximum power of a reactor is limited by the power peaking factor. During the design stage it is calculated with neutronic calculation codes. This is not enough for ensuring its value due to modelling approximations. For the RA-6s low enrichment new core a calculus-measurement correlation method have been applied. Position and magnitude of the maximum power density estimated by calculus are used by this method. For this work 249 cooper-gold alloy (1.55% Au) wires have been distributed along the core using 19 aluminium blades. Their positions have been selected using information given by a 5 groups PUMA reactor model. Wire s activity have been measured with a HPGe detector. Gold activity have been used only for verifying the calculated core spectrum. The measured power peaking factor was 2.48±0.3 (3σ), 15% above the calculated value. About 97% of measured points had less than 20% calculation-measurement difference and about 80% had less than 10%. The power peaking factor determined by this method consolidates also the calculations models. [es

  7. Canada country report

    International Nuclear Information System (INIS)

    Cottrill, Cheryl

    2008-01-01

    1 - Nuclear 2007 highlights: New Build Applications and Environmental Assessments (Ontario Power Generation (OPG), Bruce Power, Bruce Power Alberta), Refurbishments (Bruce Power's Bruce A Units 1 and 2 Restart Project, NB Power's Refurbishment of Point Lepreau, New Brunswick, Atomic Energy of Canada Limited (AECL) NRU 50. Anniversary, expansion of the solid radioactive waste storage facilities at Gentilly-2 nuclear generating station, Ontario Power Generation (OPG) Deep Geologic Repository..); 2. Nuclear overview: a. Energy policy (Future of nuclear power, state of the projects, schedule, Refurbishment), b. Public acceptance, Statements from Government Officials in Canada; c. Nuclear equipment (number and type); d. Nuclear waste management, Deep Geologic Repository; e. Nuclear research at AECL; f. Other nuclear activities (Cameco Corporation, MDS Nordion); 3. Nuclear competencies; 4. WIN 2007 Main Achievements: GIRLS Science Club, Skills Canada, WiN-Canada Web site, Book Launch, WINFO, 2007 WiN-Canada conference 4 - Summary: - 14.6% of Canada's electricity is provided by Candu nuclear reactors; Nuclear equipment: 10 Research or isotope producing reactors - Pool-Type; Slowpoke 2; Sub-Critical assembly; NRU; and Maple; 22 Candu reactors providing electricity production - 18 of which are currently operating. Public acceptance: 41% feel nuclear should play more of a role, 67% support refurbishment, 48% support new build, 13% point gender gap in support, with men supporting more than women. Energy policy: Future of nuclear power - recognition that nuclear is part of the solution across Canada; New Build - 3 applications to regulator to prepare a site for new build, in Provinces of Ontario and Alberta, with one feasibility study underway in New Brunswick; Refurbishment - Provinces of Ontario (2010) and New Brunswick (2009). Nuclear waste management policy: Proposal submitted to regulator to prepare, construct and operate a deep geologic disposal facility in Ontario

  8. 6. European conference of TRIGA reactor users. Conference papers

    International Nuclear Information System (INIS)

    1980-01-01

    The Sixth European Conference of TRIGA Users was held in September 1980, in Mainz, Germany under the joint sponsorship of INTERATOM and the Institut fur Kernchemie. The main areas of discussions were: Fuel cycle aspects; New reactor developments and improvements; TRIGA applications; Operating and maintenance experiences and Instrumentation

  9. The Thermal-hydraulic Analysis for the Aging Effect of the Component in CANDU-6 Reactor

    International Nuclear Information System (INIS)

    Bae, Jun Ho; Jung, Jong Yeob

    2014-01-01

    CANDU reactor consists of a lot of components, including pressure tube, reactor pump, steam generator, feeder pipe, and so on. These components become to have the aging characteristics as the reactor operates for a long time. The aging phenomena of these components lead to the change of operating parameters, and it finally results to the decrease of the operating safety margin. Actually, due to the aging characteristics of components, CANDU reactor power plant has the operating license for the duration of 30 years and the plant regularly check the plant operating state in the overhaul period. As the reactor experiences the aging, the reactor operators should reduce the reactor power level in order to keep the minimum safety margin, and it results to the deficit of economical profit. Therefore, in order to establish the safety margin for the aged reactor, the aging characteristics for components should be analyzed and the effect of aging of components on the operating parameter should be studied. In this study, the aging characteristics of components are analyzed and revealed how the aging of components affects to the operating parameter by using NUCIRC code. Finally, by scrutinizing the effect of operating parameter on the operating safety margin, the effect of aging of components on the safety margin has been revealed

  10. The contract of design of an atomic reactor system in Yonggwang - 5, 6 nuclear power plant

    International Nuclear Information System (INIS)

    1995-05-01

    This is a contract of design of an atomic reactor system in Yonggwang 5, 6 nuclear power plant. It has the general contract condition. In the appendix, it indicates the detail regulations between two parties which are the coverage of division on the responsibility, schedule of the delivery, standard of the technology, guarantee, drawing and paper support of the Korea Electric Power Corporation, support of technology drill, test, regulations of code and standard and list of items and prices.

  11. Reactor technology progress report on Joyo, vol. 6

    International Nuclear Information System (INIS)

    1982-01-01

    The works of the Technology Section, Fast Experimental Reactor Division, Power Reactor and Nuclear Fuel Development Corp., are roughly divided into core technology, anomaly monitoring techniques, plant technology, purity control techniques and operation planning and management. In this book, the state of activities in the Technology Section, the result of operation of Joyo and the foreign information related to FBRs in the quarter from July to September, 1981, are reported. The operation of Joyo of 75 MW rating No. 5 cycle was finished on August 9, and after fuel handling and FFDL test, the operation of special test cycle was carried out in September. In this quarter, main report papers were one N-report and 108 memos. The examination of the preliminary analysis and the plan for shifting to the MK-2 core and the performance test, and the planning of the core construction for the operation from No. 1 to No. 3 cycle with the MK-2 core and the analysis of its characteristics were carried out. The revision of the long term plan of the Technology Section was started in July, and the first draft was completed in September. The compilation of the general report on the MK-1 core was started in July. Three meetings for technical discussion within the Division were held. (Kako, I.)

  12. Licensed operating reactors: status summary report, data as of 6-30-81

    International Nuclear Information System (INIS)

    1981-07-01

    The Operating Units Status Report - Licensed Operating Reactors provides data on the operation of nuclear units as timely and accurately as possible. This information is collected by the Office of Management and Program Analysis from the Headquarters staff of NRC's Office of Inspection and Enforcement, from NRC's Regional Offices, and from utilities. The three sections of the report are: monthly highlights and statistics for commercial operating units, and errata from previously reported data; a compilation of detailed information on each unit, provided by NRC's Regional Offices, IE Headquarters and the utilities; and an appendix for miscellaneous information such as spent fuel storage capability, reactor-years of experience and non-power reactors in the U.S. It is hoped the report is helpful to all agencies and individuals interested in maintaining an awareness of the U.S. energy situation as a whole

  13. Nuclear reactors to come

    International Nuclear Information System (INIS)

    Lung, M.

    2002-01-01

    The demand for nuclear energy will continue to grow at least till 2050 because of mainly 6 reasons: 1) the steady increase of the world population, 2) China, India and Indonesia will reach higher social standard and their energy consumption will consequently grow, 3) fossil energy resources are dwindling, 4) coal will be little by little banned because of its major contribution to the emission of green house effect gas, 5) renewable energies need important technological jumps to be really efficient and to take the lead, and 6) fusion energy is not yet ready to take over. All these reasons draw a promising future for nuclear energy. Today 450 nuclear reactors are operating throughout the world producing 17% of the total electrical power demand. In order to benefit fully of this future, nuclear industry has to improve some characteristics of reactors: 1) a more efficient use of uranium (it means higher burnups), 2) a simplification and automation of reprocessing-recycling chain of processes, 3) efficient measures against proliferation and against any misuse for terrorist purposes, and 4) an enhancement of safety for the next generation of reactors. The characteristics of fast reactors and of high-temperature reactors will likely make these kinds of reactors the best tools for energy production in the second half of this century. (A.C.)

  14. Possibility of implementation of 6-year fuel cycle at NPP with VVER-440 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Heraltova, L., E-mail: lenka.heraltova@fjfi.cvut.cz [UJV Rez a.s., Hlavni 130, 250 68 Husinec-Rez (Czech Republic); Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, Brehova 7, 115 19 Praha 1 (Czech Republic)

    2015-12-15

    Highlights: • Possibility of extension of fuel cycle. • Increase of enrichment above 5% {sup 235}U. • Core properties calculated by diffusion code ANDREA. • Back end fuel cycle characteristic. - Abstract: This paper discusses possibility of an extension of a fuel cycle at a VVER-440 reactor for up to 6 years. The prolongation of a fuel cycle was realized by optimization of a fuel design and increasing of a fuel enrichment. The modified design of the fuel assembly covers change of pellet geometry, decreasing of parasitic absorption in construction materials, improved moderation of fuel pins and also increase of enrichment. Fuel assemblies with enrichment up to 7% {sup 235}U are considered for prolonged fuel batches. Three different batch lengths were considered for evaluation of core properties – 12, 18 and 24 months, and two types of burnable absorbers were included – Gd{sub 2}O{sub 3} and Er{sub 2}O{sub 3}. Comparison of proposed fuel assemblies was realized by length of a batch, average burnup, maximal power of fuel assembly or fuel pin, control fuel assembly worth, reactivity coefficients, and effective delayed neutrons fraction. Comparison of characteristics of a burned fuel discharged from a reactor core is discussed in the last part of the paper.

  15. Preliminary post-closure safety assessment of repository concepts for low level radioactive waste at the Bruce Site, Ontario

    International Nuclear Information System (INIS)

    Little, R.H.; Penfold, J.S.S.; Egan, M.J.; Leung, H.

    2005-01-01

    The preliminary post-closure safety assessment of permanent repository concepts for low-level radioactive waste (LLW) at the Ontario Power Generation (OPG) Bruce Site is described. The study considered the disposal of both short and long-lived LLW. Four geotechnically feasible repository concepts were considered (two near-surface and two deep repositories). An approach consistent with best international practice was used to provide a reasoned and comprehensive analysis of post-closure impacts of the repository concepts. The results demonstrated that the deep repository concepts in shale and in limestone, and the surface repository concept on sand should meet radiological protection criteria. For the surface repository concept on glacial till, it appears that increased engineering such as grouting of waste and voids should be considered to meet the relevant dose constraint. Should the project to develop a permanent repository for LLW proceed, it is expected that this preliminary safety assessment would need to be updated to take account of future site-specific investigations and design updates. (author)

  16. IR analyzer spots heavy water leaks

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    A correlation spectrometer developed by Barringer Research Ltd. (in collaboration with Atomic Energy of Canada and Ontario Hydro) is used to measure HDO concentrations in DTO in the final (distillation) stage of heavy-water production. A unit has been installed at Bruce Heavy Water Plant. Previously, such spectrometers had been installed to detect heavy-water leaks in CANDU reactors. The principle on which the instrument works is explained, with illustrations. It works by comparing the absorption at 2.9 μm, due to HDO, with that at 2.6 μm, due to both HDO and D 2 O. (N.D.H.)

  17. Fusion reactor materials

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    The following topics are briefly discussed: (1) surface blistering studies on fusion reactor materials, (2) TFTR design support activities, (3) analysis of samples bombarded in-situ in PLT, (4) chemical sputtering effects, (5) modeling of surface behavior, (6) ion migration in glow discharge tube cathodes, (7) alloy development for irradiation performance, (8) dosimetry and damage analysis, and (9) development of tritium migration in fusion devices and reactors

  18. Effect of increasing nitrobenzene loading rates on the performance of anaerobic migrating blanket reactor and sequential anaerobic migrating blanket reactor/completely stirred tank reactor system

    International Nuclear Information System (INIS)

    Kuscu, Ozlem Selcuk; Sponza, Delia Teresa

    2009-01-01

    A laboratory scale anaerobic migrating blanket reactor (AMBR) reactor was operated at nitrobenzene (NB) loading rates increasing from 3.33 to 66.67 g NB/m 3 day and at a constant hydraulic retention time (HRT) of 6 days to observe the effects of increasing NB concentrations on chemical oxygen demand (COD), NB removal efficiencies, bicarbonate alkalinity, volatile fatty acid (VFA) accumulation and methane gas percentage. Moreover, the effect of an aerobic completely stirred tank reactor (CSTR) reactor, following the anaerobic reactor, on treatment efficiencies was also investigated. Approximately 91-94% COD removal efficiencies were observed up to a NB loading rate of 30.00 g/m 3 day in the AMBR reactor. The COD removal efficiencies decreased from 91% to 85% at a NB loading rate of 66.67 g/m 3 day. NB removal efficiencies were approximately 100% at all NB loading rates. The maximum total gas, methane gas productions and methane percentage were found to be 4.1, 2.6 l/day and 59%, respectively, at a NB loading rate of 30.00 g/m 3 day. The optimum pH values were found to be between 7.2 and 8.4 for maximum methanogenesis. The total volatile fatty acid (TVFA) concentrations in the effluent were 110 and 70 mg/l in the first and second compartments at NB loading rates as high as 66.67 and 6.67 g/m 3 day, respectively, while they were measured as zero in the effluent of the AMBR reactor. In this study, from 180 mg/l NB 66 mg/l aniline was produced in the anaerobic reactor while aniline was completely removed and transformed to 2 mg/l of cathechol in the aerobic CSTR reactor. Overall COD removal efficiencies were found to be 95% and 99% for NB loading rates of 3.33 and 66.67 g/m 3 day in the sequential anaerobic AMBR/aerobic CSTR reactor system, respectively. The toxicity tests performed with Photobacterium phosphoreum (LCK 480, LUMIStox) and Daphnia magna showed that the toxicity decreased with anaerobic/aerobic sequential reactor system from the influent, anaerobic and to

  19. First preliminary design of an experimental fusion reactor

    International Nuclear Information System (INIS)

    1977-09-01

    A preliminary design of a tokamak experimental fusion reactor to be built in the near future is under way. The goals of the reactor are to achieve reactor-level plasma conditions for a sufficiently long operation period and to obtain design, construction and operational experience for the main components of full-scale power reactors. This design covers overall reactor system including plasma characteristics, reactor structure, blanket neutronics, shielding, superconducting magnets, neutral beam injector, electric power supply system, fuel circulating system, reactor cooling system, tritium recovery system and maintenance scheme. The main design parameters are as follows: the reactor fusion power 100 MW, torus radius 6.75 m, plasma radius 1.5 m, first wall radius 1.75 m, toroidal magnet field on axis 6 T, blanket fertile material Li 2 O, coolant He, structural material 316SS and tritium breeding ratio 0.9. (auth.)

  20. Assessment of torsatrons as reactors

    International Nuclear Information System (INIS)

    Lyon, J.F.; Painter, S.L.

    1992-12-01

    Stellarators have significant operational advantages over tokamaks as ignited steady-state reactors because stellarators have no dangerous disruptions and no need for continuous current drive or power recirculated to the plasma, both easing the first wall, blanket, and shield design; less severe constraints on the plasma parameters and profiles; and better access for maintenance. This study shows that a reactor based on the torsatron configuration (a stellarator variant) could also have up to double the mass utilization efficiency (MUE) and a significantly lower cost of electricity (COE) than a conventional tokamak reactor (ARIES-I) for a range of assumptions. Torsatron reactors can have much smaller coil systems than tokamak reactors because the coils are closer to the plasma and they have a smaller cross section (higher average current density because of the lower magnetic field). The reactor optimization approach and the costing and component models are those used in the current stage of the ARIES-I tokamak reactor study. Typical reactor parameters for a 1-GW(e) Compact Torsatron reactor example are major radius R 0 = 6.6-8.8 m, on-axis magnetic field B 0 = 4.8-7.5 T, B max (on coils) = 16 T, MUE 140-210 kW(e)/tonne, and COE (in constant 1990 dollars) = 67-79 mill/kW(e)h. The results are relatively sensitive to assumptions on the level of confinement improvement and the blanket thickness under the inboard half of the helical windings but relatively insensitive to other assumptions

  1. Three-phase packed bed reactor with an evaporating solvent—I. Experimental: the hydrogenation of 2,4,6-trinitrotoluene in methanol

    NARCIS (Netherlands)

    van Gelder, K.B.; Damhof, J.K.; Kroijenga, P.J.; Westerterp, K.R.

    1990-01-01

    In this paper we present experimental data on the three-phase hydrogenation of 2,4,6-trinitrotoluene (TNT) to triaminotoluene. The experiments are performed in a cocurrent upflow packed bed reactor. Methanol is used as an evaporating solvent. The influence of the main operating parameters, the

  2. Status of advanced technology and design for water cooled reactors: Heavy water reactors

    International Nuclear Information System (INIS)

    1989-07-01

    In 1987 the IAEA established the International Working Group on Advanced Technologies for Water-Cooled Reactors (IWGATWR). Within the framework of the IWGATWR the IAEA Technical Report on Status of Advanced Technology and Design for Water Cooled Reactors, Part I: Light Water Reactors and Part II: Heavy Water Reactors, has been undertaken to document the major current activities and trends of technological improvement and development for future water reactors. Part I of the report dealing with Light Water Reactors (LWRs) was published in 1988 (IAEA-TECDOC-479). Part II of the report covers Heavy Water Reactors (HWRs) and has now been prepared. This report is based largely upon submissions from Member States. It has been supplemented by material from the presentations at the IAEA Technical Committee and Workshop on Progress in Heavy Water Reactor Design and Technology held in Montreal, Canada, December 6-9, 1988. It is hoped that this part of the report, containing the status of advanced heavy water reactor technology up to 1988 and ongoing development programmes will aid in disseminating information to Member States and in stimulating international cooperation. Refs, figs and tabs

  3. Exocrine Gland-Secreting Peptide 1 Is a Key Chemosensory Signal Responsible for the Bruce Effect in Mice.

    Science.gov (United States)

    Hattori, Tatsuya; Osakada, Takuya; Masaoka, Takuto; Ooyama, Rumi; Horio, Nao; Mogi, Kazutaka; Nagasawa, Miho; Haga-Yamanaka, Sachiko; Touhara, Kazushige; Kikusui, Takefumi

    2017-10-23

    The Bruce effect refers to pregnancy termination in recently pregnant female rodents upon exposure to unfamiliar males [1]. This event occurs in specific combinations of laboratory mouse strains via the vomeronasal system [2, 3]; however, the responsible chemosensory signals have not been fully identified. Here we demonstrate that the male pheromone exocrine gland-secreting peptide 1 (ESP1) is one of the key factors that causes pregnancy block. Female mice exhibited high pregnancy failure rates upon encountering males that secreted different levels of ESP1 compared to the mated male. The effect was not observed in mice that lacked the ESP1 receptor, V2Rp5, which is expressed in vomeronasal sensory neurons. Prolactin surges in the blood after mating, which are essential for maintaining luteal function, were suppressed by ESP1 exposure, suggesting that a neuroendocrine mechanism underlies ESP1-mediated pregnancy failure. The single peptide pheromone ESP1 conveys not only maleness to promote female receptivity but also the males' characteristics to facilitate memorization of the mating partner. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Volume reduction/solidification of liquid radioactive waste using bitumen at Ontario hydro's Bruce nuclear generating station open-quotes Aclose quotes

    International Nuclear Information System (INIS)

    Day, J.E.; Baker, R.L.

    1994-01-01

    Ontario Hydro at the Bruce Nuclear Generating Station open-quotes Aclose quotes has undertaken a program to render the station's liquid radioactive waste suitable for discharge to Lake Huron by removing sufficient radiological and chemical contaminants from five different plant waste streams. The contaminants will be immobilized and stored at on-site radioactive waste storage facilities and the purified streams will be discharged. The discharge targets established by Ontario Hydro are set well below the limits established by the Ontario Ministry of Environment (MOE) and are based on the Best Available Technology Economically Achievable Approach (B.A.T.E.A.). ADTECHS Corporation has been selected by Ontario Hydro to provide volume reduction/solidification technology for one of the five waste streams. The system will dry and immobilize the contaminants from a liquid waste stream in emulsified asphalt using thin film evaporation technology

  5. Proceedings of the US Nuclear Regulatory Commission fifteenth water reactor safety information meeting: Volume 6, Decontamination and decommissioning, accident management, TMI-2

    International Nuclear Information System (INIS)

    Weiss, A.J.

    1988-02-01

    This six-volume report contains 140 papers out of the 164 that were presented at the Fifteenth Water Reactor Safety Information Meeting held at the National Bureau of Standards, Gaithersburg, Maryland, during the week of October 26-29, 1987. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. This report, Volume 6, discusses decontamination and decommissioning, accident management, and the Three Mile Island-2 reactor accident. Thirteen reports have been cataloged separately

  6. Neutronics of a mixed-flow gas-core reactor

    International Nuclear Information System (INIS)

    Soran, P.D.; Hansen, G.E.

    1977-11-01

    The study was made to investigate the neutronic feasibility of a mixed-flow gas-core reactor. Three reactor concepts were studied: four- and seven-cell radial reactors and a seven-cell scallop reactor. The reactors were fueled with UF 6 (either U-233 or U-235) and various parameters were varied. A four-cell reactor is not practical nor is the U-235 fueled seven-cell radial reactor; however, the 7-cell U-233 radial and scallop reactors can satisfy all design criteria. The mixed flow gas core reactor is a very attractive reactor concept and warrants further investigation

  7. Irradiation of fuels and materials in the Jules Horowitz reactor: The 6th European Union JHR co-ordination action (JHR-CA)

    International Nuclear Information System (INIS)

    Iracane, Daniel; Parrat, Daniel

    2005-01-01

    The Fermine thematic network in the 5th FP pointed out the need for a new MTR facility in Europe to answer the continuous need of irradiation capabilities for fission power reactors and fusion facilities and to face the ageing of present MTRs. The Jules Horowitz Reactor (JHR) Project in Cadarache copes with this context, as an international service-oriented user-facility. In the field of nuclear fuels and materials irradiation experiments, a 6th FP co-ordination action, called JHR-CA, has started at the beginning of 2004 for 2 years. The main objective is to network existing expertise on development of a new generation of experimental devices, through definition of conceptual designs, instrumentation and related in-reactor services. This paper presents the outline of the JHR project, the organization of the JHR-CA programme, and a choice of irradiation device conceptual design results. (author)

  8. Simulation of LOFT anticipated-transient experiments L6-1, L6-2, and L6-3 using TRAC-PF1/MOD1

    International Nuclear Information System (INIS)

    Sahota, M.S.

    1984-01-01

    Anticipated-transient experiments L6-1, L6-2, and L6-3, performed at the Loss-of-fluid Test (LOFT) facility, are analyzed using the latest released version of the Transient Reactor Analysis Code (TRAC-PF1/MOD1). The results are used to assess TRAC-PF1/MOD1 trip and control capabilities, and predictions of thermal-hydraulic phenomena during slow transients. Test L6-1 simulated a loss-of-stream load in a large pressurized-water reactor (PWR), and was initiated by closing the main steam-flow control valve (MSFCV) at its maximum rate, which reduced the heat removal from the secondary-coolant system and increased the primary-coolant system pressure that initiated a reactor scram. Test L6-2 simulated a loss-of-primary coolant flow in a large PWR, and was initiated by tripping the power to the primary-coolant pumps (PCPs) allowing the pumps to coast down. The reduced primary-coolant flow caused a reactor scram. Test L6-3 simulated an excessive-load increase incident in a large PWR, and was initiated by opening the MSFCV at its maximum rate, which increased the heat removal from the secondary-coolant system and decreased the primary-coolant system pressure that initiated a reactor scram. The TRAC calculations accurately predict most test events. The test data and the calculated results for most parameters of interest also agree well

  9. Reactor core structure

    International Nuclear Information System (INIS)

    Higashinakagawa, Emiko; Sato, Kanemitsu.

    1992-01-01

    Taking notice on the fact that Fe based alloys and Ni based alloys are corrosion resistant in a special atmosphere of a nuclear reactor, Fe or Ni based alloys are applied to reactor core structural components such as fuel cladding tubes, fuel channels, spacers, etc. On the other hand, the neutron absorption cross section of zirconium is 0.18 barn while that of iron is 2.52 barn and that of nickel is 4.6 barn, which amounts to 14 to 25 times compared with that of zirconium. Accordingly, if the reactor core structural components are constituted by the Fe or Ni based alloys, neutron economy is lowered. Since it is desirable that neutrons contribute to uranium fission with least absorption to the reactor core structural components, the reactor core structural components are constituted with the Fe or Ni based alloys of good corrosion resistance only at a portion in contact with reactor water, that is, at a surface portion, while the main body is constituted with zircalloy in the present invention. Accordingly, corrosion resistnace can be kept while keeping small neutron absorption cross section. (T.M.)

  10. Molten salt reactors

    International Nuclear Information System (INIS)

    Bouchter, J.C.; Dufour, P.; Guidez, J.; Simon, N.; Renault, C.

    2014-01-01

    Molten salt reactors are one of the 6 concepts retained for the 4. generation of nuclear reactors. The principle of this reactor is very innovative: the nuclear fuel is dissolved in the coolant which allows the online reprocessing of the fuel and the online recovery of the fission products. A small prototype: the Molten Salt Reactor Experiment (MSRE - 8 MWt) was operating a few years in the sixties in the USA. The passage towards a fast reactor by the suppression of the graphite moderator leads to the concept of Molten Salt Fast Reactor (MSFR) which is presently studied through different European projects such as MOST, ALISIA and EVOL. Worldwide the main topics of research are: the adequate materials resisting to the high level of corrosiveness of the molten salts, fuel salt reprocessing, the 3-side coupling between neutron transport, thermohydraulics and thermo-chemistry, the management of the changing chemical composition of the salt, the enrichment of lithium with Li 7 in the case of the use of lithium fluoride salt and the use of MSFR using U 233 fuel (thorium cycle). The last part of the article presents a preliminary safety analysis of the MSFR. (A.C.)

  11. International Working Group on Fast Reactors Sixth Annual Meeting. Summary Report

    International Nuclear Information System (INIS)

    1973-01-01

    The Agenda of the Meeting was as follows: 1. Review of IWGFR Activities - 1a. Approval of the minutes of the Fifth IWGFR Meeting. 1b. Report by Scientific Secretary regarding the activities of the Group. 2. Comments on National Programmes on Fast Breeder Reactors. 3. International Coordination of the Schedule for Major Fast Reactor Meetings and other major international meetings having a predominant fast reactor interest. 4. Consideration of Conferences on Fast Reactors. 4a. IAEA Symposium on Fuel and Fuel Elements for Fast Reactors, Brussels, Belgium 2-6 July 1973. 4b. International Symposium on Physics of Fast Reactors, Tokyo, Japan, 16 to 23 October 1973. 4c. International Conference on Fast Reactor Power Stations, London, UK, 11 to 14 March 1974 . 4d. Suggestions of the IWGFR members on other conferences. 5. Consideration of a Schedule for Specialists' Meetings in 1973-74. 6. Other Business - 6a. First-aid in Sodium Burns. 6b. Principles of Good Practice for Safe Operation of Sodium Circuits. 6c. Bibliography on Fast Reactors. 7. The Date and Place of the Seventh Annual Meeting of the IWGFR

  12. Comparison between TRU burning reactors and commercial fast reactor

    International Nuclear Information System (INIS)

    Fujimura, Koji; Sanda, Toshio; Ogawa, Takashi

    2001-03-01

    additional consideration should be required in nuclear design and fuel treating facilities due to reactivity coefficient being shifted to the plus side, larger neutron yield and increased heat source caused by MA loading. (2) Confirmation of TRU burning reactor core concepts. The core specification of sodium cooled-nitride fueled TRU burning large reactor was designed based on commercial type fast reactor (sodium cooled nitride fueled large fast reactor, 38000 MWt) which was designed in the feasibility studies on commercialized fast reactor cycle system. The composition of MAs from LWR's spent fuel was supposed. MA content in the core fuel is settled to 60 wt% based on the JAERI's design in order to maximize the MA transmutation amount. We need to exchange 25% of core fuel with zirconium hydride (ZrH 1.6 ) to attain Doppler coefficient being equivalent to that of the conventional type commercial fast reactor loaded 5 wt% MA. Furthermore, this reactor could transmute MAs produced in forty-eight sodium cooled nitride fueled large fast reactors generating the same output. In order to investigate the dependency of MA transmutation characteristics on the reactor output, 1200 MWt TRU burning middle or small reactor core concept was designed. This core was settled by reducing the number of core fuel assemblies from that of TRU burning large reactor designed above. MA transmutation rate in this core is smaller than that in the TRU burning large reactor core because the neutron flux of this core becomes smaller than that of the TRU burning large reactor core due to the higher Pu enrichment. (3) Comparison between TRU burning reactor and conventional type commercial fast reactor. MA transmutation and nuclear characteristics of the sodium cooled nitride fuel commercial type fast reactor loaded 5 wt%MA were evaluated and compared with those of TRU burning large reactor designed in (2). The commercial type fast reactor could only transmute MAs produced in seven sodium cooled nitride

  13. PC-version of RAM6-code for calculation of parameters of the effective logarithmic boundary condition at the absorbent rod surface in reactor

    International Nuclear Information System (INIS)

    Le Van Ngoc; Ngo Dang Nhan

    1990-01-01

    The RAM-6 code for calculation of parameters of the effective logarithmic boundary condition at the absorbent rod surface in reactor is suitably modofied to work on IBM PC, the instructions for its usage are presented and capabilities of the personal cpmputer oriented RAM-6 code are demonstrated. (author). 4 refs, 5 tabs, 2 figs

  14. VERONA V6.22 – An enhanced reactor analysis tool applied for continuous core parameter monitoring at Paks NPP

    Energy Technology Data Exchange (ETDEWEB)

    Végh, J., E-mail: janos.vegh@ec.europa.eu [Institute for Energy and Transport of the Joint Research Centre of the European Commission, Postbus 2, NL-1755 ZG Petten (Netherlands); Pós, I., E-mail: pos@npp.hu [Paks Nuclear Power Plant Ltd., H-7031 Paks, P.O. Box 71 (Hungary); Horváth, Cs., E-mail: csaba.horvath@energia.mta.hu [Centre for Energy Research, Hungarian Academy of Sciences, H-1525 Budapest 114, P.O. Box 49 (Hungary); Kálya, Z., E-mail: kalyaz@npp.hu [Paks Nuclear Power Plant Ltd., H-7031 Paks, P.O. Box 71 (Hungary); Parkó, T., E-mail: parkot@npp.hu [Paks Nuclear Power Plant Ltd., H-7031 Paks, P.O. Box 71 (Hungary); Ignits, M., E-mail: ignits@npp.hu [Paks Nuclear Power Plant Ltd., H-7031 Paks, P.O. Box 71 (Hungary)

    2015-10-15

    Between 2003 and 2007 the Hungarian Paks NPP performed a large modernization project to upgrade its VERONA core monitoring system. The modernization work resulted in a state-of-the-art system that was able to support the reactor thermal power increase to 108% by more accurate and more frequent core analysis. Details of the new system are given in Végh et al. (2008), the most important improvements were as follows: complete replacement of the hardware and the local area network; application of a new operating system and porting a large fraction of the original application software to the new environment; implementation of a new human-system interface; and last but not least, introduction of new reactor physics calculations. Basic novelty of the modernized core analysis was the introduction of an on-line core-follow module based on the standard Paks NPP core design code HELIOS/C-PORCA. New calculations also provided much finer spatial resolution, both in terms of axial node numbers and within the fuel assemblies. The new system was able to calculate the fuel applied during the first phase of power increase accurately, but it was not tailored to determine the effects of burnable absorbers as gadolinium. However, in the second phase of the power increase process the application of fuel assemblies containing three fuel rods with gadolinium content was intended (in order to optimize fuel economy), therefore off-line and on-line VERONA reactor physics models had to be further modified, to be able to handle the new fuel according to the accuracy requirements. In the present paper first a brief overview of the system version (V6.0) commissioned after the first modernization step is outlined; then details of the modified off-line and on-line reactor physics calculations are described. Validation results for new modules are treated extensively, in order to illustrate the extent and complexity of the V&V procedure associated with the development and licensing of the new

  15. The analysis for inventory of experimental reactor high temperature gas reactor type

    International Nuclear Information System (INIS)

    Sri Kuntjoro; Pande Made Udiyani

    2016-01-01

    Relating to the plan of the National Nuclear Energy Agency (BATAN) to operate an experimental reactor of High Temperature Gas Reactors type (RGTT), it is necessary to reactor safety analysis, especially with regard to environmental issues. Analysis of the distribution of radionuclides from the reactor into the environment in normal or abnormal operating conditions starting with the estimated reactor inventory based on the type, power, and operation of the reactor. The purpose of research is to analyze inventory terrace for Experimental Power Reactor design (RDE) high temperature gas reactor type power 10 MWt, 20 MWt and 30 MWt. Analyses were performed using ORIGEN2 computer code with high temperatures cross-section library. Calculation begins with making modifications to some parameter of cross-section library based on the core average temperature of 570 °C and continued with calculations of reactor inventory due to RDE 10 MWt reactor power. The main parameters of the reactor 10 MWt RDE used in the calculation of the main parameters of the reactor similar to the HTR-10 reactor. After the reactor inventory 10 MWt RDE obtained, a comparison with the results of previous researchers. Based upon the suitability of the results, it make the design for the reactor RDE 20MWEt and 30 MWt to obtain the main parameters of the reactor in the form of the amount of fuel in the pebble bed reactor core, height and diameter of the terrace. Based on the main parameter or reactor obtained perform of calculation to get reactor inventory for RDE 20 MWT and 30 MWT with the same methods as the method of the RDE 10 MWt calculation. The results obtained are the largest inventory of reactor RDE 10 MWt, 20 MWt and 30 MWt sequentially are to Kr group are about 1,00E+15 Bq, 1,20E+16 Bq, 1,70E+16 Bq, for group I are 6,50E+16 Bq, 1,20E+17 Bq, 1,60E+17 Bq and for groups Cs are 2,20E+16 Bq, 2,40E+16 Bq, 2,60E+16 Bq. Reactor inventory will then be used to calculate the reactor source term and it

  16. Prospect of realizing nuclear fusion reactors

    International Nuclear Information System (INIS)

    1989-01-01

    This Report describes the results of the research work on nuclear fusion, which CRIEPI has carried out for about ten years from the standpoint of electric power utilities, potential user of its energy. The principal points are; (a) economic analysis (calculation of costs) based on Japanese analysis procedures and database of commercial fusion reactors, including fusion-fission hybrid reactors, and (b) conceptual design of two types of hybrid reactors, that is, fission-fuel producing DMHR (Demonstration Molten-Salt Hybrid Reactor) and electric-power producing THPR (Tokamak Hybrid Power Reactor). The Report consists of the following chapters: 1. Introduction. 2. Conceptual Design of Hybrid Reactors. 3. Economic Analysis of Commercial Fusion Reactors. 4. Basic Studies Applicable Also to Nuclear Fusion Technology. 5. List of Published Reports and Papers; 6. Conclusion. Appendices. (author)

  17. Program planning for large-scale control system upgrades

    International Nuclear Information System (INIS)

    Madani, M.; Giajnorio, J.; Richard, T.; Ho, D.; Volk, W.; Ertel, A.

    2011-01-01

    Bruce Power has been planning to replace the Bruce A Fuel Handling (FH) computer systems including the Controller and Protective computers for many years. This is a complex project, requiring an extended FH outage. To minimize operational disruption and fully identify associated project risks, Bruce Power is executing the project in phases starting with the Protective Computer replacement. GEH-C is collaborating with Bruce Power in a Preliminary Engineering (PE) phase to generate a project plan including specifications, budgetary cost, schedule, risks for the Protective computer replacement project. To assist Bruce Power in its evaluation, GEH-C's is using 6-Sigma methodologies to identify and rank Critical to Quality (CTQ) requirements in collaboration with Bruce Power Maintenance, Operations, Plant Design and FH Engineering teams. PE phase established the project scope, hardware and software specifications, material requirements and finally concluded with a recommended hardware platform and approved controls architecture.

  18. Development of nuclear fuel. Development of CANDU advanced fuel bundle

    International Nuclear Information System (INIS)

    Suk, Ho Chun; Hwang, Woan; Jeong, Young Hwan; Jung, Sung Hoon

    1991-07-01

    In order to develop CANDU advanced fuel, the agreement of the joint research between KAERI and AECL was made on February 19, 1991. AECL conceptual design of CANFLEX bundle for Bruce reactors was analyzed and then the reference design and design drawing of the advanced fuel bundle with natural uranium fuel for CANDU-6 reactor were completed. The CANFLEX fuel cladding was preliminarily investigated. The fabricability of the advanced fuel bundle was investigated. The design and purchase of the machinery tools for the bundle fabrication for hydraulic scoping tests were performed. As a result of CANFLEX tube examination, the tubes were found to be meet the criteria proposed in the technical specification. The dummy bundles for hydraulic scoping tests have been fabricated by using the process and tools, where the process parameters and tools have been newly established. (Author)

  19. Advances in Reactor Physics, Mathematics and Computation. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    1987-01-01

    These proceedings of the international topical meeting on advances in reactor physics, mathematics and computation, volume one, are divided into 6 sessions bearing on: - session 1: Advances in computational methods including utilization of parallel processing and vectorization (7 conferences) - session 2: Fast, epithermal, reactor physics, calculation, versus measurements (9 conferences) - session 3: New fast and thermal reactor designs (9 conferences) - session 4: Thermal radiation and charged particles transport (7 conferences) - session 5: Super computers (7 conferences) - session 6: Thermal reactor design, validation and operating experience (8 conferences).

  20. Next generation light water reactors

    International Nuclear Information System (INIS)

    Omoto, Akira

    1992-01-01

    In the countries where the new order of nuclear reactors has ceased, the development of the light water reactors of new type has been discussed, aiming at the revival of nuclear power. Also in Japan, since it is expected that light water reactors continue to be the main power reactor for long period, the technology of light water reactors of next generation has been discussed. For the development of nuclear power, extremely long lead time is required. The light water reactors of next generation now in consideration will continue to be operated till the middle of the next century, therefore, they must take in advance sufficiently the needs of the age. The improvement of the way men and the facilities should be, the simple design, the flexibility to the trend of fuel cycle and so on are required for the light water reactors of next generation. The trend of the development of next generation light water reactors is discussed. The construction of an ABWR was started in September, 1991, as No. 6 plant in Kashiwazaki Kariwa Power Station. (K.I.)

  1. Okulo natural reactors

    International Nuclear Information System (INIS)

    Yamakawa, Minoru

    1993-01-01

    French CEA has reported in 1972 that natural nuclear reactors existed in Okulo uranium deposit in Gabon in Africa, that caused nuclear fission chain reaction (Okulo phenomena) spontaneously two billion years ago. The fission products and transuranic elements produced by the natural reactors have been preserved in strata without movement while subjected to geological phenomena for such very long years. 16 zones of the natural reactors have been discovered so far. The geological features of the Okulo uranium deposit are explained. The total amount of 235 U lost by the chain reaction was estimated to be about 6t, and the fission products were about 6t. The Okulo phenomena offered the valuable results of the synthetic formation disposal test that the nature has carried out for such long years. The significance of the study on natural analog is discussed. Organic substances and the mechanism of holding and movement of uranium and fission nuclides, the stability of uraninite and the age measurement of the deposit by Nd-Sm process are reported as the main results. (K.I.)

  2. Nuclear reactors

    International Nuclear Information System (INIS)

    Yoshioka, Michiko.

    1985-01-01

    Purpose: To obtain an optimum structural arrangement of IRM having a satisfactory responsibility to the inoperable state of a nuclear reactor and capable of detecting the reactor power in an averaged manner. Constitution: As the structural arrangement of IRM, from 6 to 16 even number of IRM are bisected into equial number so as to belong two trip systems respectively, in which all of the detectors are arranged at an equal pitch along a circumference of a circle with a radius rl having the center at the position of the central control rod in one trip system, while one detector is disposed near the central control rod and other detectors are arranged substantially at an equal pitch along the circumference of a circle with a radius r2 having the center at the position for the central control rod in another trip system. Furthermore, the radius r1 and r2 are set such that r1 = 0.3 R, r2 = 0.5 R in the case where there are 6 IRM and r1 = 0.4 R and R2 = 0.8 R where there are eight IRM where R represents the radius of the reactor core. (Kawakami, Y.)

  3. Development of technologies for nuclear reactors of small and medium sized; Desarrollo de Tecnologias para Reactores Nucleares de pequeno y medio tamano

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-08-15

    This meeting include: countries presentations, themes and objectives of the training course, reactor types, design, EPR, APR1400, A P 1000, A PWR, ATMEA 1, VVER-1000, A PWR, ATMEA 1, VVER 1200, Boiling Water Reactor, A BWR, A BWR -II, ESBUR, Ke ren, AREVA, Heavy Water Reactor, Candu 6, Acr-1000, HWR, Bw, Iris, CAREM NuCcale, Smart, KLT-HOS, Westinghouse small modular Reactor, Gas Cooled Reactors, PBMR, React ores enfriados con metales liquidos, Hs, Prism,Terra Power, Hyper ion, appliance's no electric as de energia, Generation IV Reactors,VHTR, Gas Fast Reactor, Sodium Fast Reactor, Molten salt Reactor, Lfr, Water Cooled Reactor, Technology Assessment Process, Fukushima accident.

  4. Monte Carlo estimation of the dose and heating of cobalt adjuster rods irradiated in the CANDU 6 reactor core

    International Nuclear Information System (INIS)

    Gugiu, D.; Dumitrache, I.

    2005-01-01

    The present work is a part of a more complex project related to the replacement of the original stainless steel adjuster rods with cobalt assemblies in the CANDU 6 reactor core. The 60 Co produced by 59 Co irradiation could be used extensively in medicine and industry. The paper will mainly describe some of the reactor physics and safety requirements that must be carried into practice for the Co adjuster rods. The computations related to the neutronic equivalence of the stainless steel adjusters with the Co adjuster assemblies, as well as the estimations of the activity and heating of the irradiated cobalt rods, are performed using the Monte Carlo codes MCNP5 and MONTEBURNS 2.1. The activity values are used to evaluate the dose at the surface of the device designed to transport the cobalt adjusters. (authors)

  5. Sterilization of swine wastewater treated by anaerobic reactors using UV photo-reactors

    Directory of Open Access Journals (Sweden)

    Erlon Lopes Pereira

    2014-09-01

    Full Text Available The use of ultraviolet radiation is an established procedure with growing application forthe disinfection of contaminated wastewater. This study aimed to evaluate the efficiency of artificial UV radiation, as a post treatment of liquid from anaerobic reactors treating swine effluent. The UV reactors were employed to sterilize pathogenic microorganisms. To this end, two photo-reactors were constructed using PVC pipe with100 mm diameter and 1060 mmlength, whose ends were sealed with PVC caps. The photo-reactors were designed to act on the liquid surface, as the lamp does not get into contact with the liquid. To increase the efficiency of UV radiation, photo-reactors were coated with aluminum foil. The lamp used in the reactors was germicidal fluorescent, with band wavelength of 230 nm, power of 30 Watts and manufactured by Techlux. In this research, the HRT with the highest removal efficiency was 0.063 days (90.6 minutes, even treating an effluent with veryhigh turbidity due to dissolved solids. It was concluded that the sterilization method using UV has proved to be an effective and appropriate process, among many other procedures.

  6. Feasibility of ISO 14000 certification for the RA-6 reactor of the Bariloche Atomic Center

    International Nuclear Information System (INIS)

    Gho, Carlos J.

    2003-01-01

    The strengths and weaknesses of a proposal to set up a System for the Environmental Management of RA-6 reactor are reviewed. With this aim: The facility, its surroundings, its institutional frame, and the links of both the National Atomic Energy Commission and the Bariloche Atomic Center with the environmental issues are described. The RA-6 past and present regarding the environment is analyzed. The existence of an abundant documentation on procedures and manuals for administrative and technical management, as well as records of environmental behavior is determined. A summary is made of the work done with the staff in order to assess their motivation to develop this type of initiative, and their degree of knowledge and awareness of environmental issues. It is worthy to point out the high professional training of the RA-6 staff. This information is analyzed under the point of view of ISO 14001 both text and philosophy. It is shown that there exist important strengths that enable to face a concrete project, and that the weaknesses are few, most of them can be overcome somehow easily. The opportunity is remarkable. Conclusion is made that RA-6 is not only in optimal conditions to face successfully the implementation of an Environmental Management System, but it has already a rudimentary one

  7. Safety features in small integral PWR ABV-6

    Energy Technology Data Exchange (ETDEWEB)

    Baranaev, Youry D. [State Scientific Centre of Russian Federation - Institure for Physics and Power Engineering, Obninsk (Russian Federation)

    1996-04-15

    Long term operation experience of Bilibin Nuclear Power Plant with four EGP-6 reactors of 48MWth each at Chukotka peninsula, as well as results of manifold feasibility studies showed that Small Reactors (SR) have and will have promising market potential in outlying isolated regions of Russia as viable alternative of fossil fuel energy sources. Detailed design and licensing of the Small Floating Nuclear Power Plant Valamin/1/ with two integral pressurized water reactors ABV-6/2, 3/ is under way in Russia. The basic ABV-6 reactor design performance are presented in Table 1.

  8. Evaluation of tritium production rate in a gas-cooled reactor with continuous tritium recovery system for fusion reactors

    Energy Technology Data Exchange (ETDEWEB)

    Matsuura, Hideaki, E-mail: mat@nucl.kyushu-u.ac.jp [Department of Applied Quantum Physics and Nuclear Engineering, Kyushu University, 744 Motooka, Fukuoka 819-0395 (Japan); Nakaya, Hiroyuki; Nakao, Yasuyuki [Department of Applied Quantum Physics and Nuclear Engineering, Kyushu University, 744 Motooka, Fukuoka 819-0395 (Japan); Shimakawa, Satoshi; Goto, Minoru; Nakagawa, Shigeaki [Japan Atomic Energy Agency, 4002 Oarai, Ibaraki 311-1393 (Japan); Nishikawa, Masabumi [Graduate School of Engineering Science, Kyushu University, 6-10-1 Hakozaki, Fukuoka 812-8581 (Japan)

    2013-10-15

    Highlights: • The performance of a gas-cooled reactor as a tritium production system was studied. • A continuous tritium recovery using helium gas was considered. • Gas-cooled reactors with 3 GW output in all can produce ∼6 kg of tritium in a year • Performance of the system was examined for Li{sub 4}SiO{sub 4}, Li{sub 2}TiO{sub 3} and LiAlO{sub 2} compounds. -- Abstract: The performance of a high-temperature gas-cooled reactor as a tritium production with continuous tritium recovery system is examined. A gas turbine high-temperature reactor of 300-MWe (600 MW) nominal capacity (GTHTR300) is assumed as the calculation target, and using the continuous-energy Monte Carlo transport code MVP-BURN, burn-up simulations for the three-dimensional entire-core region of the GTHTR300 were performed. A Li loading pattern for the continuous tritium recovery system in the gas-cooled reactor is presented. It is shown that module gas-cooled reactors with a total thermal output power of 3 GW in all can produce ∼6 kg of tritium maximum in a year.

  9. INC '93 overview

    International Nuclear Information System (INIS)

    Howe, Bruce

    1993-01-01

    At the close of the International Nuclear Congress, INC '93, held in Toronto in October 1993, Bruce Howe, then president of AECL, presented a 'Review and Conclusions' under the following headings: Introduction, Future Energy Requirements, Economics of electricity generation, Radioactive waste management, Reactor safety, Public acceptance, Technology developments, Future energy strategies, Conclusion

  10. Calculation of photon dose for Dalat research reactor in case of loss of reactor tank water

    International Nuclear Information System (INIS)

    Le Vinh Vinh; Huynh Ton Nghiem; Nguyen Kien Cuong

    2007-01-01

    Photon sources of actinides and fission products were estimated by ORIGEN2 code with the modified cross-section library for Dalat research reactor (DRR) using new cross-section generated by WIMS-ANL code. Photon sources of reactor tank water calculated from the experimental data. MCNP4C2 with available non-analog Monte Carlo model and ANSI/ANL-6.1.1-1977 flux-to-dose factors were used for dose estimation. The agreement between calculation results and those of measurements showed that the methods and models used to get photon sources and dose were acceptable. In case the reactor water totally leaks out from the reactor tank, the calculated dose is very high at the top of reactor tank while still low in control room. In the reactor hall, the operation staffs can access for emergency works but with time limits. (author)

  11. Evaluation of Torsatrons as reactors

    International Nuclear Information System (INIS)

    Lyon, J.F.; Gulec, K.; Miller, R.L.; El-Guebaly, L.

    1994-03-01

    Stellarators have significant operational advantages over tokamaks as ignited steady-state reactors. This scoping study, which uses an integrated cost-minimization code that incorporates costing and reactor component models self-consistently with a 1-D energy transport calculation, shows that a torsatron reactor could also be economically competitive with a tokamak reactor. The projected cost of electricity (COE) estimated using the Advanced Reactor Innovation and Evaluation Studies (ARIES) costing algorithms is 65.6 mill/kW(e)h in constant 1992 dollars for a reference 1-GW(e) Compact Torsatron reactor case. The COE is relatively insensitive (<10% variation) over a wide range of assumptions, including variations in the maximum field allowed on the coils, the coil elongation, the shape of the density profile, the beta limit, the confinement multiplier, and the presence of a large loss region for alpha particles. The largest variations in the COE occur for variations in the electrical power output demanded and the plasma-coil separation ratio

  12. Fuel bundle impact velocities due to reverse flow

    International Nuclear Information System (INIS)

    Wahba, N.N.; Locke, K.E.

    1996-01-01

    If a break should occur in the inlet feeder or inlet header of a CANDU reactor, the rapid depressurization will cause the channel flow(s) to reverse. Depending on the gap between the upstream bundle and shield plug, the string of bundles will accelerate in the reverse direction and impact with the upstream shield plug. The reverse flow impact velocities have been calculated for various operating states for the Bruce NGS A reactors. The sensitivity to several analysis assumptions has been determined. (author)

  13. IFPE/MT4-MT6A-LOCA, Large-break LOCA in-reactor fuel bundle materials tests at NRU

    International Nuclear Information System (INIS)

    Cunningham, Mitchel E.; Turnbull, J.A.

    2003-01-01

    Description - Objectives - Results: The U.S. Nuclear Regulatory Commission (NRC) conducted a series of thermal-hydraulic and cladding mechanical deformation tests in the National Research Universal (NRU) reactor at the Chalk River National Laboratory in Canada. The objective of these tests was to perform simulated loss-of-coolant-accident (LOCA) experiments using full-length light-water reactor fuel rods to study mechanical deformation, flow blockage, and coolability. Three phases of a LOCA (i.e., heat-up, reflood, and quench) were performed in situ using nuclear fissioning to simulate the low-level decay power during a LOCA after shutdown. All tests used PWR-type, non-irradiated fuel rods. Provided here is information on two materials tests, MT-6A and MT-4, which PNNL considers the better characterized for the purposes of setting up computer cases. The NRU reactor is a heterogeneous, thermal, tank-type research reactor. It has a power level of 135 MWth and is heavy-water moderated and cooled. The coolant has an inlet temperature of 310 K at a pressure of 0.65 MPa. The MT tests were conducted in a specially designed test train to supply the specified coolant conditions of flowing steam, stagnant steam, and then reflood. Typical instrumentation for the MT tests included fuel centerline thermocouples, cladding inner surface thermocouples, cladding outer surface thermocouples, rod internal gas pressure transducers or pressure switches, coolant channel steam probes, and self-powered neutron detectors. This instrumentation allowed for determining rupture times and cladding temperature. The test rods for the LOCA cases in the NRU reactor were irradiated in flowing steam prior to the transient, stagnant steam during the transient and prior to reflood, and then reflood conditions to complete the transient. Both cladding inner surface and outer surface temperatures were measured, in addition to coolant temperatures. However, only cladding inner surface temperatures were

  14. International topical meeting. Research Reactor Fuel Management (RRFM) and meeting of the International Group on Reactor Research (IGORR)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    Nuclear research and test reactors have been in operation for over 60 years, over 270 research reactors are currently operating in more than 50 countries. This meeting is dedicated to different aspects of research reactor fuels: new fuels for new reactors, the conversion to low enriched uranium fuels, spent fuel management and computational tools for core simulation. About 80 contributions are reported in this document, they are organized into 7 sessions: 1) international topics and overview on new projects and fuel, 2) new projects and upgrades, 3) fuel development, 4) optimisation and research reactor utilisation, 5) innovative methods in research reactors physics, 6) safety, operation and research reactor conversion, 7) fuel back-end management, and a poster session. Experience from Australian, Romanian, Libyan, Syrian, Vietnamese, South-African and Ghana research reactors are reported among other things. The Russian program for research reactor spent fuel management is described and the status of the American-driven program for the conversion to low enriched uranium fuels is presented. (A.C.)

  15. Light water reactor fuel analysis code. FEMAXI-6 (Ver.1). Detailed structure and user's manual

    International Nuclear Information System (INIS)

    Suzuki, Motoe; Saitou, Hiroaki

    2006-02-01

    A light water reactor fuel analysis code FEMAXI-6 is an advanced version which has been produced by integrating the former version FEMAXI-V with numerous functional improvements and extensions. In particular, the FEMAXI-6 code has attained a complete coupled solution of thermal analysis and mechanical analysis, enabling an accurate prediction of pellet-clad gap size and PCMI in high burnup fuel rods. Also, such new models have been implemented as pellet-clad bonding and fission gas bubble swelling, and linkage function with detailed burning analysis code has been enhanced. Furthermore, a number of new materials properties and parameters have been introduced. With these advancements, the FEMAXI-6 code has been upgraded to a versatile analytical tool for high burnup fuel behavior not only in the normal operation but also in anticipated transient conditions. This report describes in detail the design, basic theory and structure, models and numerical method, improvements and extensions, and method of model modification. In order to facilitate effective and wide-ranging application of the code, formats and methods of input/output of the code are also described, and a sample output in an actual form is included. (author)

  16. Fusion reactors as a future energy source

    International Nuclear Information System (INIS)

    Seifritz, W.

    A detailed update of fusion research concepts is given. Discussions are given for the following areas: (1) the magnetic confinement principle, (2) UWMAK I: conceptual design for a fusion reactor, (3) the inertial confinement principle, (4) the laser fusion power plant, (5) electron-induced fusion, (6) the long-term development potential of fusion reactors, (7) the symbiosis between fusion and fission reactors, (8) fuel supply for fusion reactors, (9) safety and environmental impact, and (10) accidents, and (11) waste removal and storage

  17. Nuclear Energy Enabling Technologies (NEET) Reactor Materials: News for the Reactor Materials Crosscut, May 2016

    Energy Technology Data Exchange (ETDEWEB)

    Maloy, Stuart Andrew [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science in Radiation and Dynamics Extremes

    2016-09-26

    In this newsletter for Nuclear Energy Enabling Technologies (NEET) Reactor Materials, pages 1-3 cover highlights from the DOE-NE (Nuclear Energy) programs, pages 4-6 cover determining the stress-strain response of ion-irradiated metallic materials via spherical nanoindentation, and pages 7-8 cover theoretical approaches to understanding long-term materials behavior in light water reactors.

  18. EQ6 Calculations for Chemical Degradation Of N Reactor (U-Metal) Spent Nuclear Fuel Waste Packages

    International Nuclear Information System (INIS)

    P. Bernot

    2001-01-01

    The Monitored Geologic Repository (MGR) Waste Package Department of the Civilian Radioactive Waste Management System Management and Operating Contractor (CRWMS M and O) performed calculations to provide input for disposal of spent nuclear fuel (SNF) from the N Reactor, a graphite moderated reactor at the Department of Energy's (DOE) Hanford Site (ref. 1). The N Reactor core was fueled with slightly enriched (0.947 wt% and 0.947 to 1.25 wt% 235 U in Mark IV and Mark IA fuels, respectively) U-metal clad in Zircaloy-2 (Ref. 1, Sec. 3). Both types of N Reactor SNF have been considered for disposal at the proposed Yucca Mountain site. For some WPs, the outer shell and inner shell may breach (Ref. 3) allowing the influx of water. Water in the WP will moderate neutrons, increasing the likelihood of a criticality event within the WP; and the water may, in time, gradually leach the fissile components from the WP, further affecting the neutronics of the system. This study presents calculations of the long-term geochemical behavior of WPs containing two multi-canister overpacks (MCO) with either six baskets of Mark IA or five baskets of Mark IV intact N Reactor SNF rods (Ref. 1, Sec. 4) and two high-level waste (HLW) glass pour canisters (GPCs) arranged according to the codisposal concept (Ref. 4). The specific study objectives were to determine: (1) The extent to which fissile uranium will remain in the WP after corrosion/dissolution of the initial WP configuration (2) The extent to which fissile uranium will be carried out of the degraded WP by infiltrating water (such that internal criticality is no longer possible, but the possibility of external criticality may be enhanced); and (3) The nominal chemical composition for the criticality evaluations of the WP design, and to suggest the range of parametric variations for additional evaluations. The scope of this calculation, the chemical compositions (and subsequent criticality evaluations) of the simulations, is limited to

  19. EQ6 Calculations for Chemical Degradation Of N Reactor (U-Metal) Spent Nuclear Fuel Waste Packages

    Energy Technology Data Exchange (ETDEWEB)

    P. Bernot

    2001-02-27

    The Monitored Geologic Repository (MGR) Waste Package Department of the Civilian Radioactive Waste Management System Management & Operating Contractor (CRWMS M&O) performed calculations to provide input for disposal of spent nuclear fuel (SNF) from the N Reactor, a graphite moderated reactor at the Department of Energy's (DOE) Hanford Site (ref. 1). The N Reactor core was fueled with slightly enriched (0.947 wt% and 0.947 to 1.25 wt% {sup 235}U in Mark IV and Mark IA fuels, respectively) U-metal clad in Zircaloy-2 (Ref. 1, Sec. 3). Both types of N Reactor SNF have been considered for disposal at the proposed Yucca Mountain site. For some WPs, the outer shell and inner shell may breach (Ref. 3) allowing the influx of water. Water in the WP will moderate neutrons, increasing the likelihood of a criticality event within the WP; and the water may, in time, gradually leach the fissile components from the WP, further affecting the neutronics of the system. This study presents calculations of the long-term geochemical behavior of WPs containing two multi-canister overpacks (MCO) with either six baskets of Mark IA or five baskets of Mark IV intact N Reactor SNF rods (Ref. 1, Sec. 4) and two high-level waste (HLW) glass pour canisters (GPCs) arranged according to the codisposal concept (Ref. 4). The specific study objectives were to determine: (1) The extent to which fissile uranium will remain in the WP after corrosion/dissolution of the initial WP configuration (2) The extent to which fissile uranium will be carried out of the degraded WP by infiltrating water (such that internal criticality is no longer possible, but the possibility of external criticality may be enhanced); and (3) The nominal chemical composition for the criticality evaluations of the WP design, and to suggest the range of parametric variations for additional evaluations. The scope of this calculation, the chemical compositions (and subsequent criticality evaluations) of the simulations, is limited

  20. Reactor BR2. Introduction

    International Nuclear Information System (INIS)

    Gubel, P.

    2001-01-01

    The BR2 is a materials testing reactor and is still one of SCK-CEN's important nuclear facilities. After an extensive refurbishment to compensate for the ageing of the installation, the reactor was restarted in April 1997. During the last three years, the availability of the installation was maintained at an average level of 97.6 percent. In the year 2000, the reactor was operated for a total of 104 days at a mean power of 56 MW. In 2000, most irradiation experiments were performed in the CALLISTO PWR loop. The report describes irradiations achieved or under preparation in 2000, including the development of advanced facilities and concept studies for new programmes. An overview of the scientific irradiation programmes as well as of the R and D programme of the BR2 reactor in 2000 is given

  1. Reactor BR2. Introduction

    Energy Technology Data Exchange (ETDEWEB)

    Gubel, P

    2001-04-01

    The BR2 is a materials testing reactor and is still one of SCK-CEN's important nuclear facilities. After an extensive refurbishment to compensate for the ageing of the installation, the reactor was restarted in April 1997. During the last three years, the availability of the installation was maintained at an average level of 97.6 percent. In the year 2000, the reactor was operated for a total of 104 days at a mean power of 56 MW. In 2000, most irradiation experiments were performed in the CALLISTO PWR loop. The report describes irradiations achieved or under preparation in 2000, including the development of advanced facilities and concept studies for new programmes. An overview of the scientific irradiation programmes as well as of the R and D programme of the BR2 reactor in 2000 is given.

  2. ''Sleeping reactor'' irradiations: Shutdown reactor determination of short-lived activation products

    International Nuclear Information System (INIS)

    Jerde, E.A.; Glasgow, D.C.

    1998-01-01

    At the High-Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory, the principal irradiation system has a thermal neutron flux (φ) of ∼ 4 x 10 14 n/cm 2 · s, permitting the detection of elements via irradiation of 60 s or less. Irradiations of 6 or 7 s are acceptable for detection of elements with half-lives of as little as 30 min. However, important elements such as Al, Mg, Ti, and V have half-lives of only a few minutes. At HFIR, these can be determined with irradiation times of ∼ 6 s, but the requirement of immediate counting leads to increased exposure to the high activity produced by irradiation in the high flux. In addition, pneumatic system timing uncertainties (about ± 0.5 s) make irradiations of 9 Be(γ,n) 8 Be, the gamma rays principally originating in the spent fuel. Upon reactor SCRAM, the flux drops to ∼ 1 x 10 10 n/cm 2 · s within 1 h. By the time the fuel elements are removed, the flux has dropped to ∼ 6 x 10 8 . Such fluxes are ideal for the determination of short-lived elements such as Al, Ti, Mg, and V. An important feature of the sleeping reactor is a flux that is not constant

  3. Main results of the analysis of internal flooding in the reactor building of Kozloduy NPP Unit 6

    International Nuclear Information System (INIS)

    Demireva, E.; Goranov, S.; Horstmann, R.

    2004-01-01

    For modernization of Units 5 and 6 of Kozloduy NPP, a comprehensive analysis of internal flooding scenarios has been carried out for the reactor building outside the containment and for the turbine hall by FRAMATOME ANP and ENPRO Consult. The objective of the presentation is to provide information on the main results obtained in the flooding analysis of the reactor building (outside containment). The flooding analysis is being performed under application of the 'Methodology and boundary conditions'. Flooding calculations are provided for all of the rooms in the reactor building outside the containment in which the fluid systems, having the capacity for flooding, are mounted. The performed functional analysis shows whether the consequences of a postulated initial event are within the NPP design or could lead to situations which are not taken into account in the design. The proposals for overcoming of identified unacceptable situations and the possible strategy of room draining are also given. Several cases of leaks inside the sealed rooms in the restricted area lead to the situation that the rooms will get totally flooded. Even if this should be acceptable from the point of view of loss of system function, the water pressure effect on the structural elements, as walls and doors, does not allow such complete filling-up. The second relevant identified effect was spreading of humidity and high temperatures to adjacent rooms. Long-lasting effects of this type have to be avoided, in order to prevent potential common cause effects on safety system equipment (authors)

  4. Tritium resources available for fusion reactors

    Science.gov (United States)

    Kovari, M.; Coleman, M.; Cristescu, I.; Smith, R.

    2018-02-01

    The tritium required for ITER will be supplied from the CANDU production in Ontario, but while Ontario may be able to supply 8 kg for a DEMO fusion reactor in the mid-2050s, it will not be able to provide 10 kg at any realistic starting time. The tritium required to start DEMO will depend on advances in plasma fuelling efficiency, burnup fraction, and tritium processing technology. It is in theory possible to start up a fusion reactor with little or no tritium, but at an estimated cost of 2 billion per kilogram of tritium saved, it is not economically sensible. Some heavy water reactor tritium production scenarios with varying degrees of optimism are presented, with the assumption that only Canada, the Republic of Korea, and Romania make tritium available to the fusion community. Results for the tritium available for DEMO in 2055 range from zero to 30 kg. CANDU and similar heavy water reactors could in theory generate additional tritium in a number of ways: (a) adjuster rods containing lithium could be used, giving 0.13 kg per year per reactor; (b) a fuel bundle with a burnable absorber has been designed for CANDU reactors, which might be adapted for tritium production; (c) tritium production could be increased by 0.05 kg per year per reactor by doping the moderator with lithium-6. If a fusion reactor is started up around 2055, governments in Canada, Argentina, China, India, South Korea and Romania will have the opportunity in the years leading up to that to take appropriate steps: (a) build, refurbish or upgrade tritium extraction facilities; (b) extend the lives of heavy water reactors, or build new ones; (c) reduce tritium sales; (d) boost tritium production in the remaining heavy water reactors. All of the alternative production methods considered have serious economic and regulatory drawbacks, and the risk of diversion of tritium or lithium-6 would also be a major concern. There are likely to be serious problems with supplying tritium for future

  5. NCSU PULSTAR reactor instrumentation upgrade. Final technical report, September 6, 1990--March 19, 1993

    International Nuclear Information System (INIS)

    Bilyj, S.J.; Perez, P.B.

    1993-01-01

    The Nuclear Reactor Program at North Carolina State University initiated an upgrade program at the NCSU PULSTAR Reactor in 1990. Twenty-year-old instrumentation is currently undergoing replacement with solid-state and current technology equipment. The financial assistance from the United States Department of Energy has been the primary source of support. This report provides the status of the first two phases of the upgrade program

  6. Bruce B fuelling-with-flow operations: fuel damage investigation

    Energy Technology Data Exchange (ETDEWEB)

    Manzer, A.M. [CANTECH Associates Ltd., Burlington, Ontario (Canada); Morikawa, D. [Atomic Energy of Canada Limited, Mississauga, Ontario (Canada); Hains, A.J.; Cichowlas, W.M. [Nuclear Safety Solutions Limited, Toronto, Ontario (Canada); Roberts, J.G.; Wylie, J. [Bruce Power, Ontario (Canada)

    2005-07-01

    This paper summarizes the fuel bundle damage characterization done by Nuclear Safety Solutions Limited (NSS) and the out-reactor flow visualization tests done at Atomic Energy of Canada Limited (AECL) to reproduce the damage observed on irradiated fuel bundles. The bearing pad damage mechanism was identified and the tests showed that a minor change to the fuelling sequence would eliminate the mechanical interaction. The change was implemented in January 2005. Since then, the bearing pad damage appears to have been greatly reduced based on the small number of discharged bundles inspected to date. (author)

  7. Bruce B fuelling-with-flow operations: fuel damage investigation

    International Nuclear Information System (INIS)

    Manzer, A.M.; Morikawa, D.; Hains, A.J.; Cichowlas, W.M.; Roberts, J.G.; Wylie, J.

    2005-01-01

    This paper summarizes the fuel bundle damage characterization done by Nuclear Safety Solutions Limited (NSS) and the out-reactor flow visualization tests done at Atomic Energy of Canada Limited (AECL) to reproduce the damage observed on irradiated fuel bundles. The bearing pad damage mechanism was identified and the tests showed that a minor change to the fuelling sequence would eliminate the mechanical interaction. The change was implemented in January 2005. Since then, the bearing pad damage appears to have been greatly reduced based on the small number of discharged bundles inspected to date. (author)

  8. Isothermal calorimeter for reactor radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Radak, B; Markovic, V [Institute of Nuclear Sciences Boris Kidric, Odeljenje za radijacionu hemiju, Vinca, Beograd (Serbia and Montenegro)

    1961-12-15

    An isothermal calorimeter with thermistors for measuring absorbed dose rates from 10{sup 4}-5-6.10{sup 5} rad/h in reactor experimental holes has been designed. A kinetics method for determining the equilibrium temperature difference has been developed, and its application in isothermal calorimetry proved. The expected accuracy in measurements within {+-} 2-5% has been proved by measurements carried out in the reactor. Some data obtained by measurements in the reactor RA are presented (author)

  9. Managing severe reactor accidents. A review and evaluation of our knowledge on reactor accidents and accident management

    International Nuclear Information System (INIS)

    Gustavsson, Veine

    2002-11-01

    The report gives a review of the results from the last years research on severe reactor accidents, and an opinion on the possibilities to refine the present strategies for accident management in Swedish and Finnish BWRs. The following aspect of reactor accidents are the major themes of the study: 1. Early pressure relief from hydrogen production; 2. Recriticality in re-flooded, degraded core; 3. Melt-through; 4. Steam explosion after melt-through; 5. Coolability of the melt after after melt-through; 6. Hydrogen fire in the reactor containment; 7. Leaking containment; 8. Hydrogen fire in the reactor building; 9. Long-time developments after a severe accident; 10. Accidents during shutdown for overhaul; 11. Information need for remedial actions. Possibilities for improving the strategies in each of these areas are discussed. The review shows that our knowledge is sufficient in the areas 1, 2, 4, 6, 8. For the other areas, more research is needed

  10. Studies of conceptual spheromak fusion reactors

    International Nuclear Information System (INIS)

    Katsurai, M.; Yamada, M.

    1982-01-01

    Preliminary design studies are carried out for a spheromak fusion reactor. Simplified circuit theory is applied to obtain the characteristic relations among various parameters of the spheromak configuration for an aspect ratio of A >or approx. 1.6. These relations are used to calculate the parameters for the conceptual designs of three types of fusion reactor: (1) the DT reactor with two-component-type operation, (2) the ignited DT reactor, and (3) the ignited catalysed-type DD reactor. With a total wall loading of approx. 4 MW.m -2 , it is found that edge magnetic fields of only approx. 4 T (DT) and approx. 9 T (Cat. DD) are required for ignited reactors of 1 m plasma (minor) radius with output powers in the gigawatt range. An assessment of various schemes of generation, compression and translation of spheromak plasmas is presented. (author)

  11. Proceedings of the 1. international conference on CANDU fuel handling systems

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-31

    Besides information on fuel loading and handling systems for CANDU and PHWR reactors, the 25 papers in these proceedings also include some on dry storage, modification to fuel strings at Bruce A, and on the SLAR (spacer location and repositioning) system for finding and moving garter springs. The individual papers have been abstracted separately.

  12. Proceedings of the 1. international conference on CANDU fuel handling systems

    International Nuclear Information System (INIS)

    1996-01-01

    Besides information on fuel loading and handling systems for CANDU and PHWR reactors, the 25 papers in these proceedings also include some on dry storage, modification to fuel strings at Bruce A, and on the SLAR (spacer location and repositioning) system for finding and moving garter springs. The individual papers have been abstracted separately

  13. Uncertainty analysis of the 35% reactor inlet header break in a CANDU 6 reactor using RELAP/SCDAPSIM/MOD4.0 with integrated uncertainty analysis option

    International Nuclear Information System (INIS)

    Dupleac, D.; Perez, M.; Reventos, F.; Allison, C.

    2011-01-01

    The RELAP/SCDAPSIM/MOD4.0 code, designed to predict the behavior of reactor systems during normal and accident conditions, is being developed as part of an international nuclear technology Software Development and Training Program (SDTP). RELAP/SCDAPSIM/MOD4.0, which is the first version of RELAP5 completely rewritten to FORTRAN 90/95/2000 standards, uses the publicly available RELAP5 and SCDAP models in combination with (a) advanced programming and numerical techniques, (b) advanced SDTP-member-developed models for LWR, HWR, and research reactor analysis, and (c) a variety of other member-developed computational packages. One such computational package is an integrated uncertainty analysis (IUA) package being developed jointly by the Technical University of Catalonia (UPC) and Innovative Systems Software (ISS). RELAP/SCDAPSIM/MOD4.0(IUA) follows the input-propagation approach using probability distribution functions to define the uncertainty of the input parameters. The main steps for this type of methodologies, often referred as to statistical approaches or Wilks’ methods, are the ones that follow: 1. Selection of the plant; 2. Selection of the scenario; 3. Selection of the safety criteria; 4. Identification and ranking of the relevant phenomena based on the safety criteria; 5. Selection of the appropriate code parameters to represent those phenomena; 6. Association of uncertainty by means of Probability Distribution Functions (PDFs) for each selected parameter; 7. Random sampling of the selected parameters according to its PDF and performing multiple computer runs to obtain uncertainty bands with a certain percentile and confidence level; 8. Processing the results of the multiple computer runs to estimate the uncertainty bands for the computed quantities associated with the selected safety criteria. RELAP/SCDAPSIM/MOD4.0(IUA) calculates the number of required code runs given the desired percentile and confidence level, performs the sampling process for the

  14. Uncertainty analysis of the 35% reactor inlet header break in a CANDU 6 reactor using RELAP/SCDAPSIM/MOD4.0 with integrated uncertainty analysis option

    Energy Technology Data Exchange (ETDEWEB)

    Dupleac, D., E-mail: danieldu@cne.pub.ro [Politehnica Univ. of Bucharest (Romania); Perez, M.; Reventos, F., E-mail: marina.perez@upc.edu, E-mail: francesc.reventos@upc.edu [Technical Univ. of Catalonia (Spain); Allison, C., E-mail: iss@cableone.net [Innovative Systems Software (United States)

    2011-07-01

    The RELAP/SCDAPSIM/MOD4.0 code, designed to predict the behavior of reactor systems during normal and accident conditions, is being developed as part of an international nuclear technology Software Development and Training Program (SDTP). RELAP/SCDAPSIM/MOD4.0, which is the first version of RELAP5 completely rewritten to FORTRAN 90/95/2000 standards, uses the publicly available RELAP5 and SCDAP models in combination with (a) advanced programming and numerical techniques, (b) advanced SDTP-member-developed models for LWR, HWR, and research reactor analysis, and (c) a variety of other member-developed computational packages. One such computational package is an integrated uncertainty analysis (IUA) package being developed jointly by the Technical University of Catalonia (UPC) and Innovative Systems Software (ISS). RELAP/SCDAPSIM/MOD4.0(IUA) follows the input-propagation approach using probability distribution functions to define the uncertainty of the input parameters. The main steps for this type of methodologies, often referred as to statistical approaches or Wilks’ methods, are the ones that follow: 1. Selection of the plant; 2. Selection of the scenario; 3. Selection of the safety criteria; 4. Identification and ranking of the relevant phenomena based on the safety criteria; 5. Selection of the appropriate code parameters to represent those phenomena; 6. Association of uncertainty by means of Probability Distribution Functions (PDFs) for each selected parameter; 7. Random sampling of the selected parameters according to its PDF and performing multiple computer runs to obtain uncertainty bands with a certain percentile and confidence level; 8. Processing the results of the multiple computer runs to estimate the uncertainty bands for the computed quantities associated with the selected safety criteria. RELAP/SCDAPSIM/MOD4.0(IUA) calculates the number of required code runs given the desired percentile and confidence level, performs the sampling process for the

  15. Rapid restoration of methanogenesis in an acidified UASB reactor treating 2,4,6-trichlorophenol (TCP).

    Science.gov (United States)

    Díaz-Báez, María Consuelo; Valderrama-Rincon, Juan Daniel

    2017-02-15

    Anaerobic bioreactors are often used for removal of xenobiotic and highly toxic pollutants from wastewater. Most of the time, the pollutant is so toxic that the stability of the reactor becomes compromised. It is well known that methanogens are one of the most sensitive organisms in the anaerobic consortia and hence the stability of the reactors is highly dependant on methanogenesis. Unfortunately few studies have focused on recovering the methanogenic activity once it has been inhibited by highly toxic pollutants. Here we establish a quick recovery strategy for neutralization of an acidified UASB reactor after failure by intoxication with an excess of TCP in the influent. Once the reactor returned to pH values compatible with methanogenesis, biogas production was re-started after one day and the system was re-acclimated to TCP. Successful removal of TCP from synthetic wastewater was shown for concentrations up to 70mg/L after restoration. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Enhancement of safety analysis reliability for a CANDU-6 reactor using RELAP-CANDU/SCAN coupled code system

    International Nuclear Information System (INIS)

    Kim, Man Woong; Choi, Yong Seog; Sin, Chul; Kim, Hyun Koon; Kim, Hho Jung; Hwang, Su Hyun; Hong, In Seob; Kim, Chang Hyo

    2005-01-01

    In LOCA analysis of the CANDU reactor, the system thermal-hydraulic code, RELAP-CANDU, alone cannot predict the transient behavior accurately. Therefore, the best estimate neutronics and system thermal-hydraulic coupled code system is necessary to describe the transient behavior with higher accuracy and reliability. To perform on-line calculation of safety analysis for CANDU reactor, a coupled thermal hydraulics-neutronics code system was developed in such a way that the best-estimate thermal-hydraulic system code for CANDU reactor, RELAP-CANDU, is coupled with the full three-dimensional reactor core kinetic code

  17. Application of fuel management calculation codes for CANDU reactor

    International Nuclear Information System (INIS)

    Ju Haitao; Wu Hongchun

    2003-01-01

    Qinshan Phase III Nuclear Power Plant adopts CANDU-6 reactors. It is the first time for China to introduce this heavy water pressure tube reactor. In order to meet the demands of the fuel management calculation, DRAGON/DONJON code is developed in this paper. Some initial fuel management calculations about CANDU-6 reactor of Qinshan Phase III are carried out using DRAGON/DONJON code. The results indicate that DRAGON/DONJON can be used for the fuel management calculation for Qinshan Phase III

  18. Cardiac magnetic resonance imaging

    African Journals Online (AJOL)

    2011-03-06

    Mar 6, 2011 ... Cardiac magnetic resonance imaging. Cardiovascular magnetic resonance imaging is becoming a routine diagnostic technique. BRUCE s sPOTTiswOOdE, PhD. MRC/UCT Medical Imaging Research Unit, University of Cape Town, and Division of Radiology, Stellenbosch University. Bruce Spottiswoode ...

  19. Practical course on reactor instrumentation

    International Nuclear Information System (INIS)

    Boeck, H.; Villa, M.

    2004-06-01

    This course is based on the description of the instrumentation of the TRIGA-reactor Vienna, which is used for training research and isotope production. It comprises the following chapters: 1. instrumentation, 2. calibration of the nuclear channels, 3. rod drop time of the control rods, 4. neutron flux density measurements using compensated ionization, 5. neutron flux density measurement with fission chambers (FC), 6. neutron flux density measurement with self-powered neutron detectors (SPND), 7. pressurized water reactor simulator, 8. verification of the radiation level during reactor operation. There is one appendix about neutron-sensitive thermocouples. (nevyjel)

  20. Compact toroid refueling of reactors

    International Nuclear Information System (INIS)

    Gouge, M.J.; Hogan, J.T.; Milora, S.L.; Thomas, C.E.

    1988-04-01

    The feasibility of refueling fusion reactors and devices such as the International Thermonuclear Engineering Reactor (ITER) with high-velocity compact toroids is investigated. For reactors with reasonable limits on recirculating power, it is concluded that the concept is not economically feasible. For typical ITER designs, the compact toroid fueling requires about 15 MW of electrical power, with about 5 MW of thermal power deposited in the plasma. At these power levels, ideal ignition (Q = ∞) is not possible, even for short-pulse burns. The pulsed power requirements for this technology are substantial. 6 ref., 1 figs

  1. RA Research nuclear reactor, Part I - RA nuclear reactor operation, maintenance and utilization in 1984

    International Nuclear Information System (INIS)

    Sotic, O.; Martinc, R.; Cupac, S.; Sulem, B.; Badrljica, R.; Majstorovic, D.; Sanovic, V.

    1984-12-01

    During the 1984 the reactor operation was limited by the temporary operating license issued by the Committee of Serbian ministry for health and social care. The reason was the non existing emergency cooling system and lack of appropriate filters in the special ventilation system. This temporary license has limited the reactor power to 2 MW from 1981. Operation of the primary cooling system was changed in order to avoid appearance of the previously noticed aluminium oxyhydrate on the surface of the fuel element claddings. The new cooling regime enabled more efficient heavy water purification. Control and maintenance of the reactor instrumentation and tools was done regularly but dependent on the availability of the spare parts. In order to enable future reliable operation of the RA reactor, according to new licensing regulations, during 1984, three major tasks are planned: building of the new emergency system, reconstruction of the existing ventilation system, and renewal of the reactor instrumentation. Financing of the planned activities will be partly covered by the IAEA. this Part I of the report includes 8 Annexes describing in detail the reactor operation, and 6 special papers dealing with the problems of reactor operation and utilization

  2. Full Core Criticality Modeling of Gas-Cooled Fast Reactor Using the SCALE6.0 and MCNP5 Code Packages

    International Nuclear Information System (INIS)

    Matijevic, M.; Jecmenica, R.; Pevec, D.; Trontl, K.

    2012-01-01

    The Gas-Cooled Fast Reactor (GFR) is one of the reactor concepts selected by the Generation IV International Forum (GIF) for the next generation of innovative nuclear energy systems. It was selected among a group of more than 100 prototypes and his commercial availability is expected by 2030. GFR has common goals of the rest GIF advanced reactor types: economy, safety, proliferation resistance, availability and sustainability. Several GFR fuel design concepts such as plates, rod pins and pebbles are currently being investigated in order to meet the high temperature constraints characteristic for a GFR working enviroment. In the previous study we have compared the fuel depletion results for heterogeneous GFR fuel assembly (FA), obtained with TRITON6 sequence of SCALE6.0 code system, with the MCNPX-CINDER90 and TRIPOLI-4-D codes. Present work is a continuation of neutronic criticality analysis of heterogeneous FA and full core configurations of a GFR concept using 3-D Monte Carlo codes KENO-VI/SCALE6.0 and MCNP5. The FA is based on a hexagonal mesh of fuel rods (uranium and plutonium carbide fuel, silicon carbide clad, helium gas coolant) with axial reflector thickness being varied for the purpose of optimization. Three reflector materials were analysed: zirconium carbide (ZrC), silicon carbide (SiC) and natural uranium. ZrC has been selected as a reflector material, having the best contribution to the neutron economy and to the reactivity of the core. The core safety parameters were also analysed: a negative temperature coefficient of reactivity was verified for the heavy metal fuel and coolant density loss. Criticality calculations of different FA active heights were performed and the reflector thickness was also adjusted. Finally, GFR full core criticality calculations using different active fuel rod heights and fixed ZrC reflector height were done to find the optimal height of the core. The Shannon entropy of the GFR core fission distribution was proved to be

  3. Reactor theory and power reactors. 1. Calculational methods for reactors. 2. Reactor kinetics

    International Nuclear Information System (INIS)

    Henry, A.F.

    1980-01-01

    Various methods for calculation of neutron flux in power reactors are discussed. Some mathematical models used to describe transients in nuclear reactors and techniques for the reactor kinetics' relevant equations solution are also presented

  4. Cleanup Verification Package for the 118-H-6:2, 105-H Reactor Ancillary Support Areas, Below-Grade Structures, and Underlying Soils; the 118-H-6:3, 105-H Reactor Fuel Storage Basin and Underlying Soils; the 118-H-6:6 Fuel Storage Basin Deep Zone Side Slope Soils; the 100-H-9, 100-H-10, and 100-H-13 French Drains; the 100-H-11 and 100-H-12 Expansion Box French Drains; and the 100-H-14 and 100-H-31 Surface Contamination Zones

    International Nuclear Information System (INIS)

    Appel, M.J.

    2006-01-01

    This cleanup verification package documents completion of removal actions for the 105-H Reactor Ancillary Support Areas, Below-Grade Structures, and Underlying Soils (subsite 118-H-6:2); 105-H Reactor Fuel Storage Basin and Underlying Soils (118-H-6:3); and Fuel Storage Basin Deep Zone Side Slope Soils. This CVP also documents remedial actions for the following seven additional waste sties: French Drain C (100-H-9), French Drain D (100-H-10), Expansion Box French Drain E (100-H-11), Expansion Box French Drain F (100-H-12), French Drain G (100-H-13), Surface Contamination Zone H (100-H-14), and the Polychlorinated Biphenyl Surface Contamination Zone (100-H-31)

  5. Permeated defect detecting test method and device in reactor

    International Nuclear Information System (INIS)

    Sakurai, Yoshishige.

    1996-01-01

    The present invention provides a method of and a device capable of performing a test for entire inner surfaces of the reactor upon periodical inspection of a BWR type reactor while sufficiently taking countermeasures for radiation rays into consideration. Namely, the present invention comprises following steps. (1) A provisional step for taking a shroud head of a reactor core shroud and incore structural components above and below the shroud out of the reactor, discharging reactor water and water tightly closing openings such as reactor wall perforation holes, (2) a pretreatment step for washing exposed inner surfaces of the reactor and peeling deteriorated materials, (3) a first drying step for drying portions washed and peeled in the step (2), (4) a permeation step for applying a permeation liquid of a defect detecting medium on the exposed inner surfaces of the reactor, (5) a permeation liquid removing step for removing the an excess permeation liquid in the step (4), (6) a second drying step for drying corresponding portions after performing the step (5), and (7) a flaw detecting step for optically observing the corresponding portions after performing the step (6) and detecting flaws. (I.S.)

  6. Utilization of thorium and U-ZrH1.6 fuels in various heterogeneous cores for TRIGA PUSPATI Reactor (RTP)

    Science.gov (United States)

    Damahuri, Abdul Hannan Bin; Mohamed, Hassan; Aziz Mohamed, Abdul; Idris, Faridah

    2018-01-01

    The use of thorium as nuclear fuel has been an appealing prospect for many years and will be great significance to nuclear power generation. There is an increasing need for more research on thorium as Malaysian government is currently active in the national Thorium Flagship Project, which was launched in 2014. The thorium project, which is still in phase 1, focuses on the research and development of the thorium extraction from mineral processing ore. Thus, the aim of the study is to investigate other alternative TRIGA PUSPATI Reactor (RTP) core designs that can fully utilize thorium. Currently, the RTP reactor has an average neutron flux of 2.797 x 1012 cm-2/s-1 and an effective multiplication factor, k eff, of 1.001. The RTP core has a circular array core configuration with six circular rings. Each ring consists of 6, 12, 18, 24, 30 or 36 U-ZrH1.6 fuel rods. There are three main type of uranium weight, namely 8.5, 12 and 20 wt.%. For this research, uranium zirconium hydride (U-ZrH1.6) fuel rods in the RTP core were replaced by thorium (ThO2) fuel rods. Seven core configurations with different thorium fuel rods placements were modelled in a 2D structure and simulated using Monte Carlo n-particle (MCNPX) code. Results show that the highest initial criticality obtained is around 1.35101. Additionally there is a significant discrepancy between results from previous study and the work because of the large estimated leakage probability of approximately 21.7% and 2D model simplification.

  7. Gamma Radiation Assessment In Kartini Reactor And Its Vicinity

    International Nuclear Information System (INIS)

    Yazid, M.; Supriyatni, E.; Maryono; Bastianudin, Aris

    2000-01-01

    Measurement to calculate dose assesment for gamma radiation in Kartini Reactor and its vicinity has been done whether on operated or un operated condition. Measurement was performed using height pressured ionization chamber, Reuther Stokes RS-112 production. Measurement location was determined based on distance variation inwardly and outwardly of reactor building and its vicinity. The result showed that the average dose rate in the reactor building when un operated is in the range of 11.4-38.6 mu rad/hour and when the reactor operated is 166.4-1910.9 mu rad/hour. While the vicinity of the reactor on operated condition the average dose rate is 34.4-38.6 mu rad/hour in un operated condition is 6.9-7.0 mu rad/hour. This result showed that the reactor operated did not rise the radiation exposure level in its vicinity. From the personnel assesment dose rate of gamma radiation is 28.54 mrem/week on operated condition, 0.90 mrem.week on un operated condition. While dose rate outside the reactor is 0.44 and 0.27 mrem/week for operated and un operated condition consecutively. This dose rate is still below maximum permissible dose than recommended by the national regulation of radiation protection from BAPETEN No. 01/Ka.BAPETEN/V-99

  8. What next for Fukushima?

    Science.gov (United States)

    Drinkwater, Bruce; Malkin, Rob

    2018-01-01

    Nearly seven years after a powerful tsunami caused catastrophic damage to Japan's Fukushima Daiichi nuclear-power plant, the clean-up and recovery is still ongoing. Bruce Drinkwater and Rob Malkin recently visited the disaster site and the undamaged Tsuruga plant to see if they can pinpoint the true extent of the damage in the dangerously radioactive reactors

  9. Behavior of the future LHC magnet protection diodes irradiated in a nuclear reactor at 4.6 K with intermediate annealing

    International Nuclear Information System (INIS)

    Berland, V.; Hagedorn, D.; Gerstenberg, H.

    1996-01-01

    In the framework of the LHC project at CERN, the effects of radiation on the electrical characteristics of epitaxial diodes for superconducting magnet protection were studied. The diodes were exposed to an irradiation dose up to 50 kGy and a neutron fluence of 10 15 n/cm 2 with intermediate thermal annealing each 10 kGy dose steps in the Technical University of Munich reactor at 4.6 K

  10. Reactor core in FBR type reactor

    International Nuclear Information System (INIS)

    Masumi, Ryoji; Kawashima, Katsuyuki; Kurihara, Kunitoshi.

    1989-01-01

    In a reactor core in FBR type reactors, a portion of homogenous fuels constituting the homogenous reactor core is replaced with multi-region fuels in which the enrichment degree of fissile materials is lower nearer to the axial center. This enables to condition the composition such that a reactor core having neutron flux distribution either of a homogenous reactor core or a heterogenous reactor core has substantially identical reactivity. Accordingly, in the transfer from the homogenous reactor core to the axially heterogenous reactor core, the average reactivity in the reactor core is substantially equal in each of the cycles. Further, by replacing a portion of the homogenous fuels with a multi-region fuels, thereby increasing the heat generation near the axial center, it is possiable to reduce the linear power output in the regions above and below thereof and, in addition, to improve the thermal margin in the reactor core. (T.M.)

  11. Commercial tokamak reactors with resistive toroidal field magnets

    International Nuclear Information System (INIS)

    Bombery, L.; Cohn, D.R.; Jassby, D.L.

    1984-01-01

    Scaling relations and design concepts are developed for commercial tokamak reactors that use watercooled copper toroidal field (TF) magnets. Illustrative parameters are developed for reactors that are scaled up in size from LITE test reactor designs, which use quasi-continuous copper plate magnets. Acceptably low magnet power requirements may be attainable in a moderate beta (β = 0.065) commercial reactor with a major radius of 6.2 m. The shielding thickness and magnet size are substantially reduced relative to values in commercial reactors with superconducting magnets. Operation at high beta (β = 0.14) leads to a reduction in reactor size, magnet-stored energy, and recirculating power. Reactors using resistive TF magnets could provide advantages of physically smaller devices, improved maintenance features, and increased ruggedness and reliability

  12. Progress of the DUPIC fuel compatibility analysis (I) - reactor physics

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hang Bok; Jeong, Chang Joon; Roh, Gyu Hong; Rhee, Bo Wook; Park, Jee Won

    2003-12-01

    Since 1992, the direct use of spent pressurized water reactor fuel in CANada Deuterium Uranium (CANDU) reactors (DUPIC) has been studied as an alternative to the once-through fuel cycle. The DUPIC fuel cycle study is focused on the technical feasibility analysis, the fabrication of DUPIC fuels for irradiation tests and the demonstration of the DUPIC fuel performance. The feasibility analysis was conducted for the compatibility of the DUPIC fuel with existing CANDU-6 reactors from the viewpoints of reactor physics, reactor safety, fuel cycle economics, etc. This study has summarized the intermediate results of the DUPIC fuel compatibility analysis, which includes the CANDU reactor physics design requirements, DUPIC fuel core physics design method, performance of the DUPIC fuel core, regional overpower trip setpoint, and the CANDU primary shielding. The physics analysis showed that the CANDU-6 reactor can accommodate the DUPIC fuel without deteriorating the physics design requirements by adjusting the fuel management scheme if the fissile content of the DUPIC fuel is tightly controlled.

  13. Operation and maintenance of the RA reactor, Report on operation in 1966, task 6.08

    International Nuclear Information System (INIS)

    Milosevic, D. and others

    1966-12-01

    During 1966, RA reactor was operated at nominal power for 196 days and 28 days at lower power levels. The total production was 31015 MWh which is 3% higher than planned. Practically there were no discrepancies from the plan. The reactor was used for irradiation and experiments according to the demand of 644 users, of which 516 were from the Institute. This report contains detailed data about reactor power and experiments performed in 1966, and a chart showing discrepancies from the plan. data concerned about the utilization of reactor experimental channels are included as well. Total number of safety shutdowns was 37, of which 20 were caused by power cuts, 10 due to voltage instabilities, 4 due to human error and 3 due to failures of instrumentation. These data are compared to safety shutdown data of previous few years. There have been no accidents which could cause any significant effects. The incidents occurred during this year are described in detail. Detailed data concerning exposure of the personnel are part of this report

  14. The fuel of nuclear reactors

    International Nuclear Information System (INIS)

    1995-03-01

    This booklet is a presentation of the different steps of the preparation of nuclear fuels performed by Cogema. The documents starts with a presentation of the different French reactor types: graphite moderated reactors, PWRs using MOX fuel, fast breeder reactors and research reactors. The second part describes the fuel manufacturing process: conditioning of nuclear materials and fabrication of fuel assemblies. The third part lists the different companies involved in the French nuclear fuel industry while part 4 gives a short presentation of the two Cogema's fuel fabrication plants at Cadarache and Marcoule. Part 5 and 6 concern the quality assurance, the safety and reliability aspects of fuel elements and the R and D programs. The last part presents some aspects of the environmental and personnel protection performed by Cogema. (J.S.)

  15. Primary circuit and reactor core T-H characteristics determination of WWER 440 reactors

    International Nuclear Information System (INIS)

    Hermansky, J.; Petenyi, V.; Zavodsky, M.

    2010-01-01

    The WWER-440 nuclear fuel vendor permanently improves the assortment of produced nuclear fuel assemblies for achieving better fuel cycle economy and reactor operation safety. During unit refuelling there also could be made some other changes in hydraulic parameters of primary circuit (change of impeller wheels, hydraulic resistance coefficient changes of internal parts of primary circuit, etc.). Therefore it is necessary to determine real coolant flow rate through the reactor during units start-up after their refuelling, and also to have the skilled methodology and computing code for analyzing factors, which affecting the inaccuracy of coolant flow redistribution determination through reactor on flows through separate parts of reactor core in any case of parallel operation of different assembly types. Computing code TH-VCR and CORFLO are used for reactor core characteristics determination for one type of fuel and control assemblies and also in case of parallel operation of different assembly types. The code TH-VCR is able to calculate coolant flow rate for different combinations of three different fuel assembly channel types and three different control assembly channel types. The CORFLO code deals the area of the reactor core which consists of 312 fuel assemblies and 37 control assemblies. Regarding the rotational 60 deg symmetry of reactor core only 1/6 of reactor core with 59 fuel assemblies is taken into account. Computing code CORFLO is verified and validated at this time. Paper presents some results from measurements of coolant flow rate through reactors during start-up after unit refuelling and short description of computing code TH-VCR and CORFLO with some calculated results. (Authors)

  16. Evaluation of VVER-1200/V-491 reactor pressure vessel integrity during large break LOCA along with SBO using MELCOR 1.8.6

    International Nuclear Information System (INIS)

    Bui Thi Hoa; Tran Chi Thanh

    2015-01-01

    After Fukushima accident and stress test recommended by IAEA for existing reactors, higher safety requirements are enforced upon nuclear power plants during design extension and severe accident conditions. Based on those arguments, Vietnam Government requests a lot of effective safety solutions, in designs proposed for the nuclear power plants in Ninh Thuan province of Vietnam, which can prevent the accident progression toward severe accidents and mitigate severe accident consequences. One of safety requirements is related to delay time of core melt during design extension condition. Especially, if the worst case of accidents occurs, the reactor vessel integrity must be maintained at least 24 hours from the beginning of the accident. With the aim at investigation of Reactor Pressure Vessel (RPV) integrity, in this study, MELCOR 1.8.6 code is used to evaluate the integrity of RPV lower head for VVER-1200/V-491 reactor during a Large Break Loss of Coolant Accident (LBLOCA) in combination with Station Blackout (SBO) event. The study figures out several parameters related to melt down progress such as: rupture position and rupture timing, the amount of hydrogen generated. Availability of the second stage hydro-accumulators (HA2) in the VVER-1200/V-491 is assumed as an additional improvement to delay the timing of core melt as well as to maintain the vessel integrity for long-term. (author)

  17. Results and recommendations from the reactor chemistry and corrosion tasks of the reactor materials program

    International Nuclear Information System (INIS)

    Baumann, E.W.; Ondrejcin, R.S.

    1990-11-01

    Within the general context of extended service life, the Reactor Materials Program was initiated in 1984. This comprehensive program addressed material performance in SRS reactor tanks and the primary coolant or Process Water System (PWS) piping. Three of the eleven tasks concerned moderator quality and corrosion mitigation. Definition and control of the stainless steel aqueous environment is a key factor in corrosion mitigation. The Reactor Materials Program systematically investigated the SRS environment and its effect on crack initiation and propagation in stainless steel, with the objective of improving this environment. The purpose of this report is to summarize the contributions of Tasks 6, 7 and 10 of the Reactor Materials Program to the understanding and control of moderator quality and its relationship to mitigation of stress corrosion cracking

  18. Commissioning of research reactors. Safety guide

    International Nuclear Information System (INIS)

    2006-01-01

    The objective of this Safety Guide is to provide recommendations on meeting the requirements for the commissioning of research reactors on the basis of international best practices. Specifically, it provides recommendations on fulfilling the requirements established in paras 6.44 and 7.42-7.50 of International Atomic Energy Agency, Safety of Research Reactors, IAEA Safety Standards Series No. NS-R-4, IAEA, Vienna (2005) and guidance and specific and consequential recommendations relating to the recommendations presented in paras 615-621 of International Atomic Energy Agency, Safety in the Utilization and Modification of Research Reactors, Safety Series No. 35-G2, IAEA, Vienna (1994) and paras 228-229 of International Atomic Energy Agency, Safety Assessment of Research Reactors and Preparation of the Safety Analysis Report, Safety Series No. 35-G1, IAEA, Vienna (1994). This Safety Guide is intended for use by all organizations involved in commissioning for a research reactor, including the operating organization, the regulatory body and other organizations involved in the research reactor project

  19. Gaseous fuel reactors for power systems

    Science.gov (United States)

    Kendall, J. S.; Rodgers, R. J.

    1977-01-01

    Gaseous-fuel nuclear reactors have significant advantages as energy sources for closed-cycle power systems. The advantages arise from the removal of temperature limits associated with conventional reactor fuel elements, the wide variety of methods of extracting energy from fissioning gases, and inherent low fissile and fission product in-core inventory due to continuous fuel reprocessing. Example power cycles and their general performance characteristics are discussed. Efficiencies of gaseous fuel reactor systems are shown to be high with resulting minimal environmental effects. A technical overview of the NASA-funded research program in gaseous fuel reactors is described and results of recent tests of uranium hexafluoride (UF6)-fueled critical assemblies are presented.

  20. Lesson Learned in Preparation for Decommissioning of Three Canadian Prototype Power Reactors

    International Nuclear Information System (INIS)

    Vickerd, Meggan; Kenny, Stephen

    2016-01-01

    Lesson learned by Canadian Nuclear Laboratories (CNL)(former AECL) in preparation for decommissioning of three Prototype Reactors is a result of various strategies used for each site. CNL is responsible for the eventual decommissioning of three prototype power reactors; Nuclear Power Demonstration (NPD), Gentilly-1 and Douglas Point. Each of the Canadian prototype power reactor sites shutdown using different strategies. Depending on the site location, configuration, and intended designation of the respective sites, the individual facility systems (ventilation, electrical system, fire detection etc.) were also shut down using different strategies and operating objectives. As CNL embarks on decommissioning the first Canadian prototype reactor, this paper will reflect on the lessons learned over the past thirty years and what CNL is adjusting in the decommissioning strategy to prepare better plans for the future. The Nuclear Power Demonstration Nuclear Generating Station (NPDNGS) was constructed in late 1950's and operated from 1962 to 1987 when it was permanently shutdown after exceeding its operational goals. The NPD reactor was the first Canadian nuclear power reactor and it consisted of a single 20 MWe pressurized heavy water reactor located on a single facility site in Rolphton, Ontario. The NPD facility was shutdown to a 'Cold, Dark and Quiet' state and is maintained using an unmanned strategy by managing the site remotely with active fire detection and security surveillance systems, minimal electrical supply and an active ventilation system which is operated periodically to allow for intermittent inspections. The Douglas Point Nuclear Generating Station (DPNGS) was constructed in the early 1960's and operated from 1968 to 1984 when it was permanently shutdown. It consisted of a 200 MW prototype Canada Deuterium Uranium (CANDU) reactor and is embedded on the Bruce Power site near Kincardine, Ontario. The Douglas Point site is maintained in a

  1. Remote handling equipment for CANDU retubing

    International Nuclear Information System (INIS)

    Crawford, G.S.; Lowe, H.

    1993-01-01

    Numet Engineering Ltd. has designed and supplied remote handling equipment for Ontario Hydro's retubing operation of its CANDU reactors at the Bruce Nuclear Generating Station. This equipment consists of ''Retubing Tool Carriers'' an'' Worktables'' which operate remotely or manually at the reactor face. Together they function to transport tooling to and from the reactor face, to position and support tooling during retubing operations, and to deliver and retrieve fuel channels and channel components. This paper presents the fundamentals of the process and discusses the equipment supplied in terms of its design, manufacturing, components and controls, to meet the functional and quality requirements of Ontario Hydro's retubing process. (author)

  2. Load-following performance and assessment of CANDU fuel

    Energy Technology Data Exchange (ETDEWEB)

    Tayal, M.; Floyd, M.; Rattan, D.; Xu, Z.; Manzer, A.; Lau, J. [Atomic Energy of Canada Limited, Mississauga, Ontario (Canada); Kohn, E. [Ontario Power Generation, Fuel and Fuel Channel Analysis Dept., Toronto, Ontario (Canada)

    1999-09-01

    Load following of nuclear reactors is now becoming an economic necessity in some countries. When nuclear power stations are operated in a load-following mode, the reactor and the fuel may be subjected to step changes in power on a weekly, daily, or even hourly basis, depending on the grid's needs. This paper updates the previous surveys of load-following capability of CANDU fuel, focusing mainly on the successful experience at the Bruce B station. As well, initial analytical assessments are provided that illustrate the capability of CANDU fuel to survive conditions other than those for which direct in-reactor evidence is available. (author)

  3. TREAT Reactor Control and Protection System

    International Nuclear Information System (INIS)

    Lipinski, W.C.; Brookshier, W.K.; Burrows, D.R.; Lenkszus, F.R.; McDowell, W.P.

    1985-01-01

    The main control algorithm of the Transient Reactor Test Facility (TREAT) Automatic Reactor Control System (ARCS) resides in Read Only Memory (ROM) and only experiment specific parameters are input via keyboard entry. Prior to executing an experiment, the software and hardware of the control computer is tested by a closed loop real-time simulation. Two computers with parallel processing are used for the reactor simulation and another computer is used for simulation of the control rod system. A monitor computer, used as a redundant diverse reactor protection channel, uses more conservative setpoints and reduces challenges to the Reactor Trip System (RTS). The RTS consists of triplicated hardwired channels with one out of three logic. The RTS is automatically tested by a digital Dedicated Microprocessor Tester (DMT) prior to the execution of an experiment. 6 refs., 5 figs., 1 tab

  4. Reactor core and initially loaded reactor core of nuclear reactor

    International Nuclear Information System (INIS)

    Koyama, Jun-ichi; Aoyama, Motoo.

    1989-01-01

    In BWR type reactors, improvement for the reactor shutdown margin is an important characteristic condition togehter with power distribution flattening . However, in the reactor core at high burnup degree, the reactor shutdown margin is different depending on the radial position of the reactor core. That is , the reactor shutdown margin is smaller in the outer peripheral region than in the central region of the reactor core. In view of the above, the reactor core is divided radially into a central region and as outer region. The amount of fissionable material of first fuel assemblies newly loaded in the outer region is made less than the amount of the fissionable material of second fuel assemblies newly loaded in the central region, to thereby improve the reactor shutdown margin in the outer region. Further, the ratio between the amount of the fissionable material in the upper region and that of the fissionable material in the lower portion of the first fuel assemblies is made smaller than the ratio between the amount of the fissionable material in the upper region and that of the fissionable material in the lower region of the second fuel assemblies, to thereby obtain a sufficient thermal margin in the central region. (K.M.)

  5. Reactor noise diagnostics based on multivariate autoregressive modeling: Application to LOFT [Loss-of-Fluid-Test] reactor process noise

    International Nuclear Information System (INIS)

    Gloeckler, O.; Upadhyaya, B.R.

    1987-01-01

    Multivariate noise analysis of power reactor operating signals is useful for plant diagnostics, for isolating process and sensor anomalies, and for automated plant monitoring. In order to develop a reliable procedure, the previously established techniques for empirical modeling of fluctuation signals in power reactors have been improved. Application of the complete algorithm to operational data from the Loss-of-Fluid-Test (LOFT) Reactor showed that earlier conjectures (based on physical modeling) regarding the perturbation sources in a Pressurized Water Reactor (PWR) affecting coolant temperature and neutron power fluctuations can be systematically explained. This advanced methodology has important implication regarding plant diagnostics, and system or sensor anomaly isolation. 6 refs., 24 figs

  6. Candu reactors with thorium fuel cycles

    International Nuclear Information System (INIS)

    Hopwood, J.M.; Fehrenbach, P.; Duffey, R.; Kuran, S.; Ivanco, M.; Dyck, G.R.; Chan, P.S.W.; Tyagi, A.K.; Mancuso, C.

    2006-01-01

    Over the last decade and a half AECL has established a strong record of delivering CANDU 6 nuclear power plants on time and at budget. Inherently flexible features of the CANDU type reactors, such as on-power fuelling, high neutron economy, fuel channel based heat transport system, simple fuel bundle configuration, two independent shut down systems, a cool moderator and a defence-in-depth based safety philosophy provides an evolutionary path to further improvements in design. The immediate milestone on this path is the Advanced CANDU ReactorTM** (ACRTM**), in the form of the ACR-1000TM**. This effort is being followed by the Super Critical Water Reactor (SCWR) design that will allow water-cooled reactors to attain high efficiencies by increasing the coolant temperature above 550 0 C. Adaptability of the CANDU design to different fuel cycles is another technology advantage that offers an additional avenue for design evolution. Thorium is one of the potential fuels for future reactors due to relative abundance, neutronics advantage as a fertile material in thermal reactors and proliferation resistance. The Thorium fuel cycle is also of interest to China, India, and Turkey due to local abundance that can ensure sustainable energy independence over the long term. AECL has performed an assessment of both CANDU 6 and ACR-1000 designs to identify systems, components, safety features and operational processes that may need to be modified to replace the NU or SEU fuel cycles with one based on Thorium. The paper reviews some of these requirements and the associated practical design solutions. These modifications can either be incorporated into the design prior to construction or, for currently operational reactors, during a refurbishment outage. In parallel with reactor modifications, various Thorium fuel cycles, either based on mixed bundles (homogeneous) or mixed channels (heterogeneous) have been assessed for technical and economic viability. Potential applications of a

  7. “Wer jetzt kein Haus hat, baut sich keines mehr”. Notes on Bruce O’Neill’s "The Space of Boredom"

    Directory of Open Access Journals (Sweden)

    George Tudorie

    2017-12-01

    Full Text Available Bruce O’Neill describes homeless men and women in Bucharest who could not navigate the downward spiral which followed the meltdown of the state-run economy after 1989. Deprived of the culturally treasured anchors of work, home, and family, and unable to participate in anything recognizably meaningful, these individuals are forced into a position of malignant contemplation, even when busy surviving. It is an experience of paralyzed restlessness which resonates with the ruins they zigzag through. The Space of Boredom captures this landscape convincingly, and in elegant prose. The book moves effortlessly from the discussion of scholarly works in a number of fields, to observation of sometimes cinematic quality. It is well argued, abundantly researched, and clear about its theoretical assumptions. If some questions remain to be answered, at least to this reader, this may be an artifact of background. Assumptions, including important ones about the nature of affects, and about boredom itself, may not be shared. Some questions of this kind will be raised in the following.

  8. Some novel on-power refuelling features of CANDU stations

    International Nuclear Information System (INIS)

    Erwin, D.; Pendlebury, B.; Watson, J.F.; Welch, A.C.

    1976-01-01

    Part A of the paper describes the reasons for, and advantages resulting from, the use of flow assisted refuelling in the CANDU type nuclear reactors at the Pickering Generating Station. A separate fuel handling system is used for each reactor unit, as distinct from the system employed at the Bruce Generating station, where the fuel handling system is shared among several units. Part B of the paper describes some of the advantages of the shared concept with particular emphasis on the availability of the fuel handling system. (author)

  9. Licensed operating reactors: status summary report, data as of May 31, 1983. Volume 7, No. 6

    International Nuclear Information System (INIS)

    1983-06-01

    The US Nuclear Regulatory Commission's monthly Licensed Operating Reactors Status Summary Report provides data on the operation of nuclear units as timely and accurately as possible. This report is divided into three sections: the first contains monthly highlights and statistics for commercial operating units, and errata from previously reported data; the second is a compilation of detailed information on each unit, provided by NRC Regional Offices, IE Headquarters and the Utilities; and the third section is an appendix for miscellaneous information such as spent fuel storage capability, reactor years of experience and non-power reactors in the United States

  10. Advances in Reactor Physics, Mathematics and Computation. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    1987-01-01

    These proceedings of the international topical meeting on advances in reactor physics, mathematics and computation, Volume 2, are divided into 7 sessions bearing on: - session 7: Deterministic transport methods 1 (7 conferences), - session 8: Interpretation and analysis of reactor instrumentation (6 conferences), - session 9: High speed computing applied to reactor operations (5 conferences), - session 10: Diffusion theory and kinetics (7 conferences), - session 11: Fast reactor design, validation and operating experience (8 conferences), - session 12: Deterministic transport methods 2 (7 conferences), - session 13: Application of expert systems to physical aspects of reactor design and operation.

  11. Effect of DUPIC cycle on CANDU reactor safety parameters

    Energy Technology Data Exchange (ETDEWEB)

    Mohamed, Nader M. A. [Atomic Energy Authority, ETRR-2, Cairo (Egypt); Badawi, Alya [Dept. of Nuclear and Radiation Engineering, Alexandria University, Alexandria (Egypt)

    2016-10-15

    Although, the direct use of spent pressurized water reactor (PWR) fuel in CANda Deuterium Uranium (CANDU) reactors (DUPIC) cycle is still under investigation, DUPIC cycle is a promising method for uranium utilization improvement, for reduction of high level nuclear waste, and for high degree of proliferation resistance. This paper focuses on the effect of DUPIC cycle on CANDU reactor safety parameters. MCNP6 was used for lattice cell simulation of a typical 3,411 MWth PWR fueled by UO{sub 2} enriched to 4.5w/o U-235 to calculate the spent fuel inventories after a burnup of 51.7 MWd/kgU. The code was also used to simulate the lattice cell of CANDU-6 reactor fueled with spent fuel after its fabrication into the standard 37-element fuel bundle. It is assumed a 5-year cooling time between the spent fuel discharges from the PWR to the loading into the CANDU-6. The simulation was carried out to calculate the burnup and the effect of DUPIC fuel on: (1) the power distribution amongst the fuel elements of the bundle; (2) the coolant void reactivity; and (3) the reactor point-kinetics parameters.

  12. Kinetic analysis of sub-prompt-critical reactor assemblies

    International Nuclear Information System (INIS)

    Das, S.

    1992-01-01

    Neutronic analysis of safety-related kinetics problems in experimental neutron multiplying assemblies has been carried out using a sub-prompt-critical reactor model. The model is based on the concept of a sub-prompt-critical nuclear reactor and the concept of instantaneous neutron multiplication in a reactor system. Computations of reactor power, period and reactivity using the model show excellent agreement with results obtained from exact kinetics method. Analytic expressions for the energy released in a controlled nuclear power excursion are derived. Application of the model to a Pulsed Fast Reactor gives its sensitivity between 4 and 5. (author). 6 refs., 4 figs., 1 tab

  13. Effect of elevated temperatures on heavy concrete structural strength in Qinshan phase 3 CANDU 6 reactor buildings

    International Nuclear Information System (INIS)

    Alikhan, S.; Khan, A.F.; Chen, S.

    2005-01-01

    Heavy concrete is commonly used inside the Qinshan Phase 3 CANDU 6 reactor buildings for radiation shielding functions in order to provide access to key areas during reactor operation. In some cases, the heavy concrete elements are also structural elements. Concerns have been raised about the functional performance of the heavy concrete structural elements, specifically the primary heat transport pump (PHTS) supporting slabs, surrounding the feeder cabinets when subjected to elevated temperatures between 42 degree C and 121 degree C and their corresponding temperature gradients on a long-term basis during the normal operation of the plant. This paper presents the results of a test investigation on the strength of heavy concrete under elevated temperature conditions being experienced by the heavy concrete structural elements around the feeder cabinet to confirm that these structural elements meet their functional requirements. The loading conditions consist subjecting the specimens to the elevated temperatures and temperature gradient noted during commissioning, including the effect of epoxy coating. The heavy concrete mix proportion and materials of the test samples (ilmenite aggregate and Portland cement) are identical to those used for heavy concrete structural elements surrounding the feeder cabinet. Subsequent to the confirmation of the functional requirements of the heavy concrete structural elements, alarm limits are recommended for these structural elements. (authors)

  14. Nuclear reactor physics course for reactor operators

    International Nuclear Information System (INIS)

    Baeten, P.

    2006-01-01

    The education and training of nuclear reactor operators is important to guarantee the safe operation of present and future nuclear reactors. Therefore, a course on basic 'Nuclear reactor physics' in the initial and continuous training of reactor operators has proven to be indispensable. In most countries, such training also results from the direct request from the safety authorities to assure the high level of competence of the staff in nuclear reactors. The aim of the basic course on 'Nuclear Reactor Physics for reactor operators' is to provide the reactor operators with a basic understanding of the main concepts relevant to nuclear reactors. Seen the education level of the participants, mathematical derivations are simplified and reduced to a minimum, but not completely eliminated

  15. Reactor core of FBR type reactor

    International Nuclear Information System (INIS)

    Hayashi, Hideyuki; Ichimiya, Masakazu.

    1994-01-01

    A reactor core is a homogeneous reactor core divided into two regions of an inner reactor core region at the center and an outer reactor core region surrounding the outside of the inner reactor core region. In this case, the inner reactor core region has a lower plutonium enrichment degree and less amount of neutron leakage in the radial direction, and the outer reactor core region has higher plutonium enrichment degree and greater amount of neutron leakage in the radial direction. Moderator materials containing hydrogen are added only to the inner reactor core fuels in the inner reactor core region. Pins loaded with the fuels with addition of the moderator materials are inserted at a ratio of from 3 to 10% of the total number of the fuel pins. The moderator materials containing hydrogen comprise zirconium hydride, titanium hydride, or calcium hydride. With such a constitution, fluctuation of the power distribution in the radial direction along with burning is suppressed. In addition, an absolute value of the Doppler coefficient can be increased, and a temperature coefficient of coolants can be reduced. (I.N.)

  16. Development of technologies for nuclear reactors of small and medium sized

    International Nuclear Information System (INIS)

    2011-08-01

    This meeting include: countries presentations, themes and objectives of the training course, reactor types, design, EPR, APR1400, A P 1000, A PWR, ATMEA 1, VVER-1000, A PWR, ATMEA 1, VVER 1200, Boiling Water Reactor, A BWR, A BWR -II, ESBUR, Ke ren, AREVA, Heavy Water Reactor, Candu 6, Acr-1000, HWR, Bw, Iris, CAREM NuCcale, Smart, KLT-HOS, Westinghouse small modular Reactor, Gas Cooled Reactors, PBMR, React ores enfriados con metales liquidos, Hs, Prism,Terra Power, Hyper ion, appliance's no electric as de energia, Generation IV Reactors,VHTR, Gas Fast Reactor, Sodium Fast Reactor, Molten salt Reactor, Lfr, Water Cooled Reactor, Technology Assessment Process, Fukushima accident.

  17. Plasma core reactor applications

    International Nuclear Information System (INIS)

    Latham, T.S.; Rodgers, R.J.

    1976-01-01

    Analytical and experimental investigations are being conducted to demonstrate the feasibility of fissioning uranium plasma core reactors and to characterize space and terrestrial applications for such reactors. Uranium hexafluoride (UF 6 ) fuel is injected into core cavities and confined away from the surface by argon buffer gas injected tangentially from the peripheral walls. Power, in the form of thermal radiation emitted from the high-temperature nuclear fuel, is transmitted through fused-silica transparent walls to working fluids which flow in axial channels embedded in segments of the cavity walls. Radiant heat transfer calculations were performed for a six-cavity reactor configuration; each cavity is approximately 1 m in diameter by 4.35 m in length. Axial working fluid channels are located along a fraction of each cavity peripheral wall

  18. Nuclear reactors

    International Nuclear Information System (INIS)

    Barre, Bertrand

    2015-10-01

    After some remarks on the nuclear fuel, on the chain reaction control, on fuel loading and unloading, this article proposes descriptions of the design, principles and operations of different types of nuclear reactors as well as comments on their presence and use in different countries: pressurized water reactors (design of the primary and secondary circuits, volume and chemistry control, backup injection circuits), boiling water reactors, heavy water reactors, graphite and boiling water reactors, graphite-gas reactors, fast breeder reactors, and fourth generation reactors (definition, fast breeding). For these last ones, six concepts are presented: sodium-cooled fast reactor, lead-cooled fast reactor, gas-cooled fast reactor, high temperature gas-cooled reactor, supercritical water-cooled reactor, and molten salt reactor

  19. Non-electric applications of pool-type nuclear reactors

    International Nuclear Information System (INIS)

    Adamov, E.O.; Cherkashov, Yu.M.; Romenkov, A.A.

    1997-01-01

    This paper recommends the use of pool-type light water reactors for thermal energy production. Safety and reliability of these reactors were already demonstrated to the public by the long-term operation of swimming pool research reactors. The paper presents the design experience of two projects: Apatity Underground Nuclear Heating Plant and Nuclear Sea-Water Desalination Plant. The simplicity of pool-type reactors, the ease of their manufacturing and maintenance make this type of a heat source attractive to the countries without a developed nuclear industry. (author). 6 figs, 1 tab

  20. Neutronic simulation of a research reactor core of (232Th, 235U)O2 fuel using MCNPX2.6 code

    International Nuclear Information System (INIS)

    Feghhi, Seyed Amir Hossein; Rezazadeh, Marzieh; Kadi, Yacine; ); Tenreiro, Claudio; Aref, Morteza; Gholamzadeh, Zohreh

    2013-01-01

    The small reactor design for the remote and less developed areas of the user countries should have simple features in view of the lack of infra-structure and resources. Many researchers consider long core life with no on-site refuelling activity as a primary feature for the small reactor design. Long core life can be achieved by enhancing internal conversion rate of fertile to fissile materials. For that purpose, thorium cycle can he adopted because a high fissile production rate of 233 U converted from 232 Th can be expected in the thermal energy region. A simple nuclear reactor core arranged 19 assemblies in hexagonal structure, using thorium-based fuel and heavy water as coolant and moderator was simulated using MCNPX2.6 code, aiming an optimized critical assembly. Optimized reflector thickness and gap between assemblies were determined to achieve minimum neutron leakage and void reactivity. The result was a more compact core, where assemblies were designed having 19-fuel pins in 1.25 pitch-to-diameter ratio. Optimum reflector thickness of 15 cm resulted in minimal neutron leakage in view of economic limitations. A 0.5 cm gap between assembles achieved more safety and 2.2 % enrichment requirements. The present feasibility study suggests a thermal core of acceptable neutronic parameters to achieve a simple and safe core. (author)

  1. RAPID-L Highly Automated Fast Reactor Concept Without Any Control Rods (1) Reactor concept and plant dynamics analyses

    International Nuclear Information System (INIS)

    Kambe, Mitsuru; Tsunoda, Hirokazu; Mishima, Kaichiro; Iwamura, Takamichi

    2002-01-01

    The 200 kWe uranium-nitride fueled lithium cooled fast reactor concept 'RAPID-L' to achieve highly automated reactor operation has been demonstrated. RAPID-L is designed for Lunar base power system. It is one of the variants of RAPID (Refueling by All Pins Integrated Design), fast reactor concept, which enable quick and simplified refueling. The essential feature of RAPID concept is that the reactor core consists of an integrated fuel assembly instead of conventional fuel subassemblies. In this small size reactor core, 2700 fuel pins are integrated altogether and encased in a fuel cartridge. Refueling is conducted by replacing a fuel cartridge. The reactor can be operated without refueling for up to 10 years. Unique challenges in reactivity control systems design have been attempted in RAPID-L concept. The reactor has no control rod, but involves the following innovative reactivity control systems: Lithium Expansion Modules (LEM) for inherent reactivity feedback, Lithium Injection Modules (LIM) for inherent ultimate shutdown, and Lithium Release Modules (LRM) for automated reactor startup. All these systems adopt lithium-6 as a liquid poison instead of B 4 C rods. In combination with LEMs, LIMs and LRMs, RAPID-L can be operated without operator. This is the first reactor concept ever established in the world. This reactor concept is also applicable to the terrestrial fast reactors. In this paper, RAPID-L reactor concept and its transient characteristics are presented. (authors)

  2. Cascade: a high-efficiency ICF power reactor

    International Nuclear Information System (INIS)

    Pitts, J.H.

    1985-01-01

    Cascade attains a net power-plant efficiency of 49% and its cost is competitive with high-temperature gas-cooled reactor, pressurized-water reactor, and coal-fired power plants. The Cascade reactor and blanket are made of ceramic materials and activation is 6 times less than that of the MARS Tandem Mirror Reactor operating at comparable power. Hands-on maintenance of the heat exchangers is possible one day after shutdown. Essentially all tritium is recovered in the vacuum system, with the remainder recovered from the helium power conversion loop. Tritium leakage external to the vacuum system and power conversion loop is only 0.03 Ci/d

  3. Effect of temperature on selenium removal from wastewater by UASB reactors.

    Science.gov (United States)

    Dessì, Paolo; Jain, Rohan; Singh, Satyendra; Seder-Colomina, Marina; van Hullebusch, Eric D; Rene, Eldon R; Ahammad, Shaikh Ziauddin; Carucci, Alessandra; Lens, Piet N L

    2016-05-01

    The effect of temperature on selenium (Se) removal by upflow anaerobic sludge blanket (UASB) reactors treating selenate and nitrate containing wastewater was investigated by comparing the performance of a thermophilic (55 °C) versus a mesophilic (30 °C) UASB reactor. When only selenate (50 μM) was fed to the UASB reactors (pH 7.3; hydraulic retention time 8 h) with excess electron donor (lactate at 1.38 mM corresponding to an organic loading rate of 0.5 g COD L(-1) d(-1)), the thermophilic UASB reactor achieved a higher total Se removal efficiency (94.4 ± 2.4%) than the mesophilic UASB reactor (82.0 ± 3.8%). When 5000 μM nitrate was further added to the influent, total Se removal was again better under thermophilic (70.1 ± 6.6%) when compared to mesophilic (43.6 ± 8.8%) conditions. The higher total effluent Se concentration in the mesophilic UASB reactor was due to the higher concentrations of biogenic elemental Se nanoparticles (BioSeNPs). The shape of the BioSeNPs observed in both UASB reactors was different: nanospheres and nanorods, respectively, in the mesophilic and thermophilic UASB reactors. Microbial community analysis showed the presence of selenate respirers as well as denitrifying microorganisms. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. PLM and the single reactor utility - or how a single reactor utility can face the PLM issues

    International Nuclear Information System (INIS)

    Ross, M.H.

    1994-01-01

    Although Gentilly-2 reactor was planned to last for 30 years, its life could be significantly shorter if nothing were done, whereas retubing and refurbishment after, say, 25 years should result in an extension of service life to 45-50 years. In the long run, dimensional changes rather than hydriding may prove to be the pressure tubes' life limiting factor. Hydro Quebec, New Brunswick Power and AECL have an agreement to cooperate in developing a life management program for CANDU-6 reactors. The author expresses the opinion that cost-benefit criteria should be introduced in regulatory decision making. 6 refs., 9 figs

  5. Reactor core for LMFBR type reactors

    International Nuclear Information System (INIS)

    Masumi, Ryoji; Azekura, Kazuo; Kurihara, Kunitoshi; Bando, Masaru; Watari, Yoshio.

    1987-01-01

    Purpose: To reduce the power distribution fluctuations and obtain flat and stable power distribution throughout the operation period in an LMFBR type reactor. Constitution: In the inner reactor core region and the outer reactor core region surrounding the same, the thickness of the inner region is made smaller than the axial height of the reactor core region and the radial width thereof is made smaller than that of the reactor core region and the volume thereof is made to 30 - 50 % for the reactor core region. Further, the amount of the fuel material per unit volume in the inner region is made to 70 - 90 % of that in the outer region. The difference in the neutron infinite multiplication factor between the inner region and the outer region is substantially constant irrespective of the burnup degree and the power distribution fluctuation can be reduced to about 2/3, by which the effect of thermal striping to the reactor core upper mechanisms can be moderated. Further, the maximum linear power during operation can be reduced by 3 %, by which the thermal margin in the reactor core is increased and the reactor core fuels can be saved by 3 %. (Kamimura, M.)

  6. BNL ALARA Center: ALARA Notes, No. 9

    International Nuclear Information System (INIS)

    Khan, T.A.; Xie, J.W.; Beckman, M.C.

    1994-02-01

    This issue of the Brookhaven National Laboratory's Alara Notes includes the agenda for the Third International Workshop on ALARA and specific instructions on the use of the on-line fax-on-demand service provided by BNL. Other topics included in this issue are: (1) A discussion of low-level discharges from Canadian nuclear plants, (2) Safety issues at French nuclear plants, (3) Acoustic emission as a means of leak detection, (4) Replacement of steam generators at Doel-3, Beaznau, and North Anna-1, (5) Remote handling equipment at Bruce, (6) EPRI's low level waste program, (7) Radiation protection during concrete repairs at Savannah River, (8) Reactor vessel stud removal/repair at Comanche Peak-1, (9) Rework of reactor coolant pump motors, (10) Restoration of service water at North Anna-1 and -2, (11) Steam generator tubing problems at Mihama-1, (12) Full system decontamination at Indian Point-2, (13) Chemical decontamination at Browns Ferry-2, and (14) Inspection methodolody in France and Japan

  7. Effluent releases at the TRIGA reactor facility

    Energy Technology Data Exchange (ETDEWEB)

    Whittemore, W L [General Atomic Co., San Diego, CA (United States)

    1974-07-01

    The principal effluent from the operating TRIGA reactors in our facility is argon-41. As monitored by a recording gas and particulate stack monitor, the values shown in the table, the Mark III operating 24 hours per day for very long periods produced the largest amount of radioactive argon. The quantity of 23.7 Ci A-41 when diluted by the normal reactor room ventilation system corresponded to 1.45 x 10{sup -6} {mu}Ci/cc. As diluted in the roof stack stream and the reactor building wake, the concentration immediately outside the reactor building was 25% MPC for an unrestricted area. The continued dilution of this effluent resulted in a concentration of a few percent MPC at the site boundary (unrestricted area) 350 meters from the reactor. (author)

  8. Development of operation management database for research reactors

    International Nuclear Information System (INIS)

    Zhang Xinjun; Chen Wei; Yang Jun

    2005-01-01

    An Operation Database for Pulsed Reactor has been developed on the platform for Microsoft visual C++ 6.0. This database includes four function modules, fuel elements management, incident management, experiment management and file management. It is essential for reactor security and information management. (authors)

  9. Preliminary shielding design evaluation for reactor assembly of SMART

    International Nuclear Information System (INIS)

    Kim, Kyo Youn; Kang, Chang M.; Kim, Ha Yong; Zee, Sung Quun; Chang, Moon Hee

    1999-03-01

    This report describes a preliminary evaluations of SMART shielding design near the reactor core by using the DORT two-dimensional discrete ordinates transport code. The results indicate that maximum neutron fluence at the bottom of reactor vessel is 1.64x10 17 n/cm 2 and that on the radial surface of reactor vessel is 6.71x10 16 n/cm 2 . These results meet the requirement, 1.0x10 20 n/cm 2 , in 10 CFR 50.61 and the integrity of SMART reactor vessel is confirmed during the lifetime of reactor. (Author). 20 refs., 11 tabs., 8 figs

  10. Reactor for exothermic reactions

    Science.gov (United States)

    Smith, L.A. Jr.; Hearn, D.; Jones, E.M. Jr.

    1993-03-02

    A liquid phase process is described for oligomerization of C[sub 4] and C[sub 5] isoolefins or the etherification thereof with C[sub 1] to C[sub 6] alcohols wherein the reactants are contacted in a reactor with a fixed bed acid cation exchange resin catalyst at an LHSV of 5 to 20, pressure of 0 to 400 psig and temperature of 120 to 300 F. Wherein the improvement is the operation of the reactor at a pressure to maintain the reaction mixture at its boiling point whereby at least a portion but less than all of the reaction mixture is vaporized. By operating at the boiling point and allowing a portion of the reaction mixture to vaporize, the exothermic heat of reaction is dissipated by the formation of more boil up and the temperature in the reactor is controlled.

  11. David Schimmelpenninck van der Oye and Bruce W. Menning, eds., Reforming the Tsar's Army: Military Innovation in Imperial Russia from Peter the Great to the Revolution, Washington, DC: Woodrow Wilson Center and Cambridge: Cambridge UP, 2004.

    Directory of Open Access Journals (Sweden)

    David Stone

    2006-11-01

    Full Text Available David Schimmelpenninck and Bruce Menning have produced an excellent volume collecting contributions of a number of both well-established and junior scholars on the history and development of the tsarist military, grouped together around the general theme of reform. In some ways, it is comparable to Eric Lohr and Marshall Poe's complementary The Military and Society in Russia, 1450-1917 (Leiden, 2002. Schimmelpenninck and Menning's contributors, however, focus more on political and institutio...

  12. Sulfide toxicity kinetics of a uasb reactor

    Directory of Open Access Journals (Sweden)

    D. R. Paula Jr.

    2009-12-01

    Full Text Available The effect of sulfide toxicity on kinetic parameters of anaerobic organic matter removal in a UASB (up-flow anaerobic sludge blanket reactor is presented. Two lab-scale UASB reactors (10.5 L were operated continuously during 12 months. The reactors were fed with synthetic wastes prepared daily using glucose, ammonium acetate, methanol and nutrient solution. One of the reactors also received increasing concentrations of sodium sulfide. For both reactors, the flow rate of 16 L.d-1 was held constant throughout the experiment, corresponding to a hydraulic retention time of 15.6 hours. The classic model for non-competitive sulfide inhibition was applied to the experimental data for determining the overall kinetic parameter of specific substrate utilization (q and the sulfide inhibition coefficient (Ki. The application of the kinetic parameters determined allows prediction of methanogenesis inhibition and thus the adoption of operating parameters to minimize sulfide toxicity in UASB reactors.

  13. Nuclear reactor construction with bottom supported reactor vessel

    International Nuclear Information System (INIS)

    Sharbaugh, J.E.

    1987-01-01

    This patent describes an improved liquid metal nuclear reactor construction comprising: (a) a nuclear reactor core having a bottom platform support structure; (b) a reactor vessel for holding a large pool of low pressure liquid metal coolant and housing the core; (c) a containment structure surrounding the reactor vessel and having a sidewall spaced outwardly from the reactor vessel side wall and having a base mat spaced below the reactor vessel bottom end wall; (d) a central small diameter post anchored to the containment structure base mat and extending upwardly to the reactor vessel to axially fix the bottom end wall of the reactor vessel and provide a center column support for the lower end of the reactor core; (e) annular support structure disposed in the reactor vessel on the bottom end wall and extending about the lower end of the core; (f) structural support means disposed between the containment structure base mat and bottom end of the reactor vessel wall and cooperating for supporting the reactor vessel at its bottom end wall on the containment structure base mat to allow the reactor vessel to expand radially but substantially prevent any lateral motions that might be imposed by the occurrence of a seismic event; (g) a bed of insulating material disposed between the containment structure base mat and the bottom end wall of the reactor vessel and uniformly supporting the reactor vessel at its bottom end wall; freely expand radially from the central post as it heats up while providing continuous support thereof; (h) a deck supported upon the wall of the containment vessel above the top open end of the reactor vessel; and (i) extendible and retractable coupling means extending between the deck and the top open end of the reactor vessel and flexibly and sealably interconnecting the reactor vessel at its top end to the deck

  14. Research nuclear reactor RA - Annual report 1992

    International Nuclear Information System (INIS)

    Sotic, O.

    1992-12-01

    Research reactor RA Annual report for year 1992 is divided into two main parts to cover: (1) operation and maintenance and (2) activities related to radiation protection. First part includes 8 annexes describing reactor operation, activities of services for maintenance of reactor components and instrumentation, financial report and staffing. Second annex B is a paper by Z. Vukadin 'Recurrence formulas for evaluating expansion series of depletion functions' published in 'Kerntechnik' 56, (1991) No.6 (INIS record no. 23024136. Second part of the report is devoted to radiation protection issues and contains 4 annexes with data about radiation control of the working environment and reactor environment, description of decontamination activities, collection of radioactive wastes, and meteorology data [sr

  15. Ra reactor operation plan for 1976 - Annex 6

    International Nuclear Information System (INIS)

    Martinc, R.

    1976-01-01

    Contrary to previous years the RA reactor operation plan for 1976 is conditioned by more uncertainties than ever for the following reasons. It is planned for February to repair the components in order to eliminate the consequences of leaking from the vertical experimental channel VK-4 which happened in december 1975. Apart from this, measurements related to transfer of the core to highly enriched fuel under minimum power are foreseen to be performed in February. In April, it would be indispensable to locate the point of He gas leaking and its prevention. Core transfer to highly enriched fuel is planned for April for testing of the fuel elements under operating conditions and step by step increase of the power density up to the nominal power. Complete plan for core transfer would be available by the end of February 1976. It is planned to make-up for the mentioned delays from May-December 1976 [sr

  16. Programmed elimination of neutronic poisons in nuclear reactors

    International Nuclear Information System (INIS)

    Perriere, G. de la

    1967-11-01

    This work deals with the use of salts of elements having a large neutron capture cross-section, so-called 'soluble poisons' which are dissolved in the moderating water to control the reactivity of heavy-water reactors, and more particularly to compensate the xenon effect in the reactor EL 4. The report describes the controlled elimination of these poisons by fixation on ion-exchange resins. The poisons considered are lithium-6, cadmium and gadolinium in the sulphate form, and boron as boric acid. The thermodynamic and kinetic constants of the ion-exchange reactions were first determined and a study was then made of the fixation of these compounds in beds of small-calibre resins placed in columns. Lithium-6 is the poison which is most easily applicable to compensate the xenon effect in the reactor EL 4. It can be eliminated rapidly and completely from heavy water, and its use does not lead to supplementary problems of protection against the gamma radiation of the reactor circuits. (author) [fr

  17. Production of sealed sup 6 sup 0 Co and sup 1 sup 9 sup 2 Ir sources of high specific activity in the nuclear reactor RA

    International Nuclear Information System (INIS)

    Dobrijevic, R.; Vucina, J.

    1998-01-01

    Given is a review on the development of the production of 60 Co and 192 Ir performed in the Vinca Institute in the nuclear reactor RA. The experience gained showed that this reactor was suitable for obtaining of these and some other radionuclides. One possibility of its re-start is that the performances of the reactor remain the same (power 6.5 MW, max.neutron flux up to 6x10 13 n.cm -2 s -1 ). By applying new techniques of target preparation, 60 Co for sterilization units of specific activity 1.11 TBq/g could be produced. Maximal activity of sup 1 sup 9 sup 2 Ir would be about 1.48 TBq what is satisfactory for the sources for gamma radiography. The increase of the flux to 10 14 n.cm -2 s -1 would enable the production of 60 Co of specific activities about 3.335 TBq/g. This is satisfactory for the sources for the radiation therapy of activities up to 111 TBq and for gamma radiography of activities about 0.37 TBq. In the case of 192 Ir the sources for the radiation therapy of activities about 0.37 TBq could be obtained. Maximal achievable activities of 192 Ir would be about 3.7 TBq. (author)

  18. Field-reversed mirror reactor

    International Nuclear Information System (INIS)

    Carlson, G.A.

    1978-01-01

    The reactor design is a multicell arrangement wherein a series of field-reversed plasma layers are arranged along the axis of a long superconducting solenoid which provides the background magnetic field. Normal copper mirror coils and Ioffe bars placed at the first wall radius provide shallow axial and radial magnetic wells for each plasma layer. Each of 11 plasma layers requires the injection of 3.6 MW of 200 keV deuterium and tritium and produces 20 MW of fusion power. The reactor has a net electric output of 74 MWe and an estimated direct capital cost of $1200/kWe

  19. Optimizing the use of operating experience at Ontario Hydro's Bruce Nuclear Generating Station 'A'

    Energy Technology Data Exchange (ETDEWEB)

    Williams, E L [Operating Experience Reactor Safety, Bruce Nuclear Generating Station ' A' , Ontario Hydro, Tiverton, Ontario (Canada)

    1991-04-01

    One of the most significant lessons learned from the Three Mile Island event (March 1979), and again with the Chernobyl disaster - (April 1986) was the ongoing requirement to learn from our mistakes and near misses, and those of our fellow utilities around the world: so that as an industry we do not repeat the same mistakes. The very future of our industry will depend on how well each one of us accomplishes this important ask. This paper describes in detail the challenges encountered by one station when incorporating a comprehensive 'Operating Program'. It begins with the Corporate Office's directives to its stations for such a program; and follows up with the details of the actual station implementation of the program, and day to day operating experiences. The paper describes in detail the following Operating Experience programs: - Root Cause Determination process. The Institute of Nuclear Power Operations, Human Performance Enhancement System (HPES) as an integral component of the Root Cause process. Finding solutions for our station for problems identified elsewhere is covered herein; - Significant Event Recommendation Tracking System: - Commitment Tracking System; - Operating Experience (Sharing Lessons Learned) System. The paper will show all the above processes tie closely together and complement each other. The paper discusses the staff required for such processes and their training requirements. It recommends process time lines, reporting mechanisms, and sign off requirements. It will describe the equipment utilized to carry out this work effectively, and with a minimum of staff. One unique feature of the Bruce 'A' system is an 'Effectiveness Follow-Up', usually three to six months after the event recommendations have been completed. By rechecking the finished actions and reviewing them with the personnel involved with the originating event we ensure that the real root causes have been identified and resolved. (author)

  20. Optimizing the use of operating experience at Ontario Hydro's Bruce Nuclear Generating Station 'A'

    International Nuclear Information System (INIS)

    Williams, E.L.

    1991-01-01

    One of the most significant lessons learned from the Three Mile Island event (March 1979), and again with the Chernobyl disaster - (April 1986) was the ongoing requirement to learn from our mistakes and near misses, and those of our fellow utilities around the world: so that as an industry we do not repeat the same mistakes. The very future of our industry will depend on how well each one of us accomplishes this important ask. This paper describes in detail the challenges encountered by one station when incorporating a comprehensive 'Operating Program'. It begins with the Corporate Office's directives to its stations for such a program; and follows up with the details of the actual station implementation of the program, and day to day operating experiences. The paper describes in detail the following Operating Experience programs: - Root Cause Determination process. The Institute of Nuclear Power Operations, Human Performance Enhancement System (HPES) as an integral component of the Root Cause process. Finding solutions for our station for problems identified elsewhere is covered herein; - Significant Event Recommendation Tracking System: - Commitment Tracking System; - Operating Experience (Sharing Lessons Learned) System. The paper will show all the above processes tie closely together and complement each other. The paper discusses the staff required for such processes and their training requirements. It recommends process time lines, reporting mechanisms, and sign off requirements. It will describe the equipment utilized to carry out this work effectively, and with a minimum of staff. One unique feature of the Bruce 'A' system is an 'Effectiveness Follow-Up', usually three to six months after the event recommendations have been completed. By rechecking the finished actions and reviewing them with the personnel involved with the originating event we ensure that the real root causes have been identified and resolved. (author)

  1. Description of the advanced gas cooled type of reactor (AGR)

    Energy Technology Data Exchange (ETDEWEB)

    Nonboel, E. [Risoe National Lab., Roskilde (Denmark)

    1996-11-01

    The present report comprises a technical description of the Advanced Gas cooled Reactor (AGR), a reactor type which has only been built in Great Britain. 14 AGR reactors have been built, located at 6 different sites and each station is supplied with twin-reactors. The Torness AGR plant on the Lothian coastline of Scotland, 60 km east of Edinburgh, has been chosen as the reference plant and is described in some detail. Data on the other 6 stations, Dungeness B, Hinkely Point B, Hunterston G, Hartlepool, Heysham I and Heysham II, are given only in tables with a summary of design data. Where specific data for Torness AGR has not been available, corresponding data from other AGR plans has been used, primarily from Heysham II, which belongs to the same generation of AGR reactors. The information presented is based on the open literature. The report is written as a part of the NKS/RAK-2 subproject 3: `Reactors in Nordic Surroundings`, which comprises a description of nuclear power plants neighbouring the Nordic countries. (au) 11 refs.

  2. Description of the advanced gas cooled type of reactor (AGR)

    International Nuclear Information System (INIS)

    Nonboel, E.

    1996-11-01

    The present report comprises a technical description of the Advanced Gas cooled Reactor (AGR), a reactor type which has only been built in Great Britain. 14 AGR reactors have been built, located at 6 different sites and each station is supplied with twin-reactors. The Torness AGR plant on the Lothian coastline of Scotland, 60 km east of Edinburgh, has been chosen as the reference plant and is described in some detail. Data on the other 6 stations, Dungeness B, Hinkely Point B, Hunterston G, Hartlepool, Heysham I and Heysham II, are given only in tables with a summary of design data. Where specific data for Torness AGR has not been available, corresponding data from other AGR plans has been used, primarily from Heysham II, which belongs to the same generation of AGR reactors. The information presented is based on the open literature. The report is written as a part of the NKS/RAK-2 subproject 3: 'Reactors in Nordic Surroundings', which comprises a description of nuclear power plants neighbouring the Nordic countries. (au) 11 refs

  3. Hall effect measurements of Frenkel defect clustering in aluminium during high-dose reactor irradiation at 4.6 K

    International Nuclear Information System (INIS)

    Boening, K.; Mauer, W.; Pfaendner, K.; Rosner, P.

    1976-01-01

    The low-field Hall coefficient R 0 of irradiated aluminium at 4.6 K is independent of the Frenkel defect (FD) concentration, however sensitively dependent of their configuration. Since measurement of R 0 is not too difficult, rather extensive investigations of FD clustering during irradiation can be performed, but only qualitative interpretations are possible. Several pure Al samples have been irradiated with reactor neutrons at 4.6 K up to very high doses phit resp. resistivity increments Δrho 0 (maximum 91% of extrapolated saturation value Δrho 0 sup(sat) approximately 980 nΩcm). The main results are 1.FD clustering within a single displacement cascade is not a very strong effect in Al, since the R 0 values are essentially the same after reactor and after electron irradiation. Rough cascade averages are: volume Vsub(c) approximately 2.1 x 10 5 at.vol. and FD concentration csub(c) approximately 1100 ppm. 2. There is practically no dose-dependent FD clustering up to Δrho 0 approximately 350 nΩcm, since R 0 remains essentially constant there. It follows that dose-dependent FD clustering can only occur for high-order overlap of cascade volumes. The differential dose curve dΔrho 0 /dphit is perfectly linear in Δrho 0 as long as R 0 = const. 3. For Δrho 0 > 350 nΩcm FD clustering becomes increasingly important and R 0 changes strongly. Surprisingly dR 0 /dphit approximately const whence there is a constant rate of cluster size increase in spite of the vanishing rate of FD production, evidence of the continuous regrouping of the lattice and its defects. (author)

  4. 1: the atom. 2: radioactivity. 3: man and radiations. 4: the energy. 5: nuclear energy: fusion and fission. 6: the operation of a nuclear reactor. 7: the nuclear fuel cycle

    International Nuclear Information System (INIS)

    2002-01-01

    This series of 7 digest booklets present the bases of the nuclear physics and of the nuclear energy: 1 - the atom (structure of matter, chemical elements and isotopes, the four fundamental interactions, nuclear physics); 2 - radioactivity (definition, origins of radioelements, applications of radioactivity); 3 - man and radiations (radiations diversity, biological effects, radioprotection, examples of radiation applications); 4 - energy (energy states, different forms of energy, characteristics); 5 - nuclear energy: fusion and fission (nuclear energy release, thermonuclear fusion, nuclear fission and chain reaction); 6 - operation of a nuclear reactor (nuclear fission, reactor components, reactor types); 7 - nuclear fuel cycle (nuclear fuel preparation, fuel consumption, reprocessing, wastes management). (J.S.)

  5. Experiment for search for sterile neutrino at SM-3 reactor

    Science.gov (United States)

    Serebrov, A. P.; Ivochkin, V. G.; Samoylov, R. M.; Fomin, A. K.; Zinoviev, V. G.; Neustroev, P. V.; Golovtsov, V. L.; Gruzinsky, N. V.; Solovey, V. A.; Cherniy, A. V.; Zherebtsov, O. M.; Martemyanov, V. P.; Zinoev, V. G.; Tarasenkov, V. G.; Aleshin, V. I.; Petelin, A. L.; Pavlov, S. V.; Izhutov, A. L.; Sazontov, S. A.; Ryazanov, D. K.; Gromov, M. O.; Afanasiev, V. V.; Matrosov, L. N.; Matrosova, M. Yu.

    2016-11-01

    In connection with the question of possible existence of sterile neutrino the laboratory on the basis of SM-3 reactor was created to search for oscillations of reactor antineutrino. A prototype of a neutrino detector with scintillator volume of 400 l can be moved at the distance of 6-11 m from the reactor core. The measurements of background conditions have been made. It is shown that the main experimental problem is associated with cosmic radiation background. Test measurements of dependence of a reactor antineutrino flux on the distance from a reactor core have been made. The prospects of search for oscillations of reactor antineutrino at short distances are discussed.

  6. Operating performance and reliability of CANDU PHWR fuel channels in Canada

    International Nuclear Information System (INIS)

    Strachan, B.; Brown, D.R.

    1983-03-01

    CANDU nuclear plants use many small-diameter high-pressure fuel channels. Good operating performance from the CANDU fuel channels has made a major contribution to the world-leading operating record of the CANDU nuclear power plants. As of 1982 December 31, there were 7,480 fuel channels installed in 18 CANDU reactors over 500 MW(e) in size. Eight of these reactors have been declared in-service and have accumulated 24,000 fuel channel-years of operation. The only significant operating problems with fuel channels have been the occurrence of leaking cracks in 70 fuel channels and a larger amount of axial creep on the early reactors than was originally provided for in the design. Both of these problems have been corrected on all CANDU reactors built since the Bruce GS 'A' station and the newer reactors should exhibit even better performance

  7. The safety basis of the integral fast reactor program

    International Nuclear Information System (INIS)

    Pedersen, D.R.; Seidel, B.R.

    1990-01-01

    The Integral Fast Reactor (IFR) and metallic fuel have emerged as the US Department of Energy reference reactor concept and fuel system for the development of an advanced liquid-metal reactor. This article addresses the basic elements of the IFR reactor concept and focuses on the safety advances achieved by the IFR Program in the areas of (1) fuel performance, (2) superior local faults tolerance, (3) transient fuel performance, (4) fuel-failure mechanisms, (5) performance in anticipated transients without scram, (6) core-melt mitigation, and (7) actinide recycle

  8. Generation IV reactors: reactor concepts

    International Nuclear Information System (INIS)

    Cardonnier, J.L.; Dumaz, P.; Antoni, O.; Arnoux, P.; Bergeron, A.; Renault, C.; Rimpault, G.; Delpech, M.; Garnier, J.C.; Anzieu, P.; Francois, G.; Lecomte, M.

    2003-01-01

    Liquid metal reactor concept looks promising because of its hard neutron spectrum. Sodium reactors benefit a large feedback experience in Japan and in France. Lead reactors have serious assets concerning safety but they require a great effort in technological research to overcome the corrosion issue and they lack a leader country to develop this innovative technology. In molten salt reactor concept, salt is both the nuclear fuel and the coolant fluid. The high exit temperature of the primary salt (700 Celsius degrees) allows a high energy efficiency (44%). Furthermore molten salts have interesting specificities concerning the transmutation of actinides: they are almost insensitive to irradiation damage, some salts can dissolve large quantities of actinides and they are compatible with most reprocessing processes based on pyro-chemistry. Supercritical water reactor concept is based on operating temperature and pressure conditions that infers water to be beyond its critical point. In this range water gets some useful characteristics: - boiling crisis is no more possible because liquid and vapour phase can not coexist, - a high heat transfer coefficient due to the low thermal conductivity of supercritical water, and - a high global energy efficiency due to the high temperature of water. Gas-cooled fast reactors combining hard neutron spectrum and closed fuel cycle open the way to a high valorization of natural uranium while minimizing ultimate radioactive wastes and proliferation risks. Very high temperature gas-cooled reactor concept is developed in the prospect of producing hydrogen from no-fossil fuels in large scale. This use implies a reactor producing helium over 1000 Celsius degrees. (A.C.)

  9. A New In-core Production Method of Co-60 in CANDU Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Lyu, Jinqi; Kim, Woosong; Kim, Yonghee [KAIST, Daejeon (Korea, Republic of); Park, Younwon [BEES Inc, Daejeon (Korea, Republic of)

    2016-05-15

    This study introduces an innovative method for Co-60 production in the CANDU6 core. In this new scheme, the central fuel element is replaced by a Co-59 target and Co-60 is obtained after the fuel bundle is discharged. It has been shown that the new method can produce significantly higher amount of Co-60 than the conventional Co production method in CANDU6 reactors without compromising the fuel burnup by removing some (<50%) of the adjuster rods in the whole core. The coolant void reactivity is noticeably reduced when a Co-59 target is loaded into the central pin of the fuel bundle. Meanwhile, the peak power in a fuel bundle is just a little higher due to the central Co-59 target than in conventional CANDU6 fuel design. The basic technology for Co-60 producing was developed by MDS Nordion and Atomic Energy of Canada Limited (AECL) in 1946 and the same technology was adapted and applied in CANDU6 power reactors. The standard CANDU6 reactor has 21 adjuster rods which are fully inserted into the core during normal operation. The stainless steel adjuster rods are replaced with neutronically-equivalent Co-59 adjusters to produce Co-60. Nowadays, the roles of the adjuster rods are rather vague since nuclear reactors cannot be quickly restarted after a sudden reactor trip due to more stringent regulations. In some Canadian CANDU6 reactors, some or all the adjuster rods are removed from the core to maximize the uranium utilization.

  10. Operation and maintenance of 1MW PUSPATI TRIGA reactor

    International Nuclear Information System (INIS)

    Adnan Bokhari; Mohammad Suhaimi Kassim

    2006-01-01

    The Malaysian Research Reactor, Reactor TRIGA PUSPATI (RTP) has been successfully operated for 22 years for various experiments. Since its commissioning in June 1982 until December 2004, the 1MW pool-type reactor has accumulated more than 21143 hours of operation, corresponding to cumulative thermal energy release of about 14083 MW-hours. The reactor is currently in operation and normally operates on demand, which is normally up to 6 hours a day. Presently the reactor core is made up of standard TRIAGA fuel element consists of 8.5 wt%, 12 wt% and 20 wt% types; 20%-enriched and stainless steel clad. Several measures such as routine preventive maintenance and improving the reactor support systems have been taken toward achieving this long successful operation. Besides normal routine utilization like other TRIGA reactors, new strategies are implemented for effective increase in utilization. (author)

  11. Fusion reactor safety

    International Nuclear Information System (INIS)

    1987-12-01

    Nuclear fusion could soon become a viable energy source. Work in plasma physics, fusion technology and fusion safety is progressing rapidly in a number of Member States and international collaboration continues on work aiming at the demonstration of fusion power generation. Safety of fusion reactors and technological and radiological aspects of waste management are important aspects in the development and design of fusion machines. In order to provide an international forum to review and discuss the status and the progress made since 1983 in programmes related to operational safety aspects of fusion reactors, their waste management and decommissioning concepts, the IAEA had organized the Technical Committee on ''Fusion Reactor Safety'' in Culham, 3-7 November 1986. All presentations of this meeting were divided into four sessions: 1. Statements on National-International Fusion Safety Programmes (5 papers); 2. Operation and System Safety (15 papers); 3. Waste Management and Decommissioning (5 papers); 4. Environmental Impacts (6 papers). A separate abstract was prepared for each of these 31 papers. Refs, figs, tabs

  12. Fast Spectrum Molten Salt Reactor Options

    Energy Technology Data Exchange (ETDEWEB)

    Gehin, Jess C [ORNL; Holcomb, David Eugene [ORNL; Flanagan, George F [ORNL; Patton, Bruce W [ORNL; Howard, Rob L [ORNL; Harrison, Thomas J [ORNL

    2011-07-01

    During 2010, fast-spectrum molten-salt reactors (FS-MSRs) were selected as a transformational reactor concept for light-water reactor (LWR)-derived heavy actinide disposition by the Department of Energy-Nuclear Energy Advanced Reactor Concepts (ARC) program and were the subject of a preliminary scoping investigation. Much of the reactor description information presented in this report derives from the preliminary studies performed for the ARC project. This report, however, has a somewhat broader scope-providing a conceptual overview of the characteristics and design options for FS-MSRs. It does not present in-depth evaluation of any FS-MSR particular characteristic, but instead provides an overview of all of the major reactor system technologies and characteristics, including the technology developments since the end of major molten salt reactor (MSR) development efforts in the 1970s. This report first presents a historical overview of the FS-MSR technology and describes the innovative characteristics of an FS-MSR. Next, it provides an overview of possible reactor configurations. The following design features/options and performance considerations are described including: (1) reactor salt options-both chloride and fluoride salts; (2) the impact of changing the carrier salt and actinide concentration on conversion ratio; (3) the conversion ratio; (4) an overview of the fuel salt chemical processing; (5) potential power cycles and hydrogen production options; and (6) overview of the performance characteristics of FS-MSRs, including general comparative metrics with LWRs. The conceptual-level evaluation includes resource sustainability, proliferation resistance, economics, and safety. The report concludes with a description of the work necessary to begin more detailed evaluation of FS-MSRs as a realistic reactor and fuel cycle option.

  13. Core monitoring at the WNP-2 reactor

    International Nuclear Information System (INIS)

    Skeen, D.R.; Torres, R.H.; Burke, W.J.; Jenkins, I.; Jones, S.W.

    1992-01-01

    The WNP-2 reactor is a 3,323-MW(thermal) boiling water reactor (BWR) that is operated by the Washington Public Power Supply System. The WNP-2 reactor began commercial operation in 1984 and is currently in its eighth cycle. The core monitoring system used for the first cycle of operation was supplied by the reactor vendor. Cycles 2 through 6 were monitored with the POWERPLEX Core Monitoring Software System (CMSS) using the XTGBWR simulation code. In 1991, the supply system upgraded the core monitoring system by installing the POWERPLEX 2 CMSS prior to the seventh cycle of operation for WNP-2. The POWERPLEX 2 CMSS was developed by Siemens Power Corporation (SPC) and is based on SPC's advanced state-of-the-art reactor simulator code MICROBURN-B. The improvements in the POWERPLEX 2 system are possible as a result of advances in minicomputer hardware

  14. RA Research reactor, Part I: Technical and operational properties of the RA reactor; Analiza sigurnosti rada Reaktora RA I-III, Deo I: Tehnicke i pogonske karakteristike reaktora RA

    Energy Technology Data Exchange (ETDEWEB)

    Raisic, N; Zecevic, V; Nikolic, M; Popovic, B; Milosevic, M; Milic, M; Strugar, P; Pesic, M; Nikolic, V; Rajic, M; Radivojevic, J; Jankovic, M [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1963-02-15

    RA reactor is a research reactor with rather high power density. Apart from research it is used for isotope production and industrial applications due to high reactivity excess (about 11%). It is a thermal reactor, heavy water moderated, cooled by D{sub 2}O, and H{sub 2}O, with a graphite reflector. Nominal power is 6.5 MW. Fuel is 2% enriched metal uranium, reactor core height is 1220 mm, and diameter is 1405 mm. Reactor lattice is square with lattice pitch 130 mm. There is 6 horizontal experimental channels and a graphite column. There is a total of 84 fuel channels and 45 experimental channels in the core. Maximum thermal neutron flux is 5.5 10{sup 13} n/cm{sup 2} s at nominal power level.

  15. Nuclear reactor

    International Nuclear Information System (INIS)

    Hattori, Sadao; Sato, Morihiko.

    1994-01-01

    Liquid metals such as liquid metal sodium are filled in a reactor container as primary coolants. A plurality of reactor core containers are disposed in a row in the circumferential direction along with the inner circumferential wall of the reactor container. One or a plurality of intermediate coolers are disposed at the inside of an annular row of the reactor core containers. A reactor core constituted with fuel rods and control rods (module reactor core) is contained at the inside of each of the reactor core containers. Each of the intermediate coolers comprises a cylindrical intermediate cooling vessels. The intermediate cooling vessel comprises an intermediate heat exchanger for heat exchange of primary coolants and secondary coolants and recycling pumps for compulsorily recycling primary coolants at the inside thereof. Since a plurality of reactor core containers are thus assembled, a great reactor power can be attained. Further, the module reactor core contained in one reactor core vessel may be small sized, to facilitate the control for the reactor core operation. (I.N.)

  16. The CAREM reactor and present currents in reactor design

    International Nuclear Information System (INIS)

    Ordonez, J.P.

    1990-01-01

    INVAP has been working on the CAREM project since 1983. It concerns a very low power reactor for electrical energy generation. The design of the reactor and the basic criteria used were described in 1984. Since then, a series of designs have been presented for reactors which are similar to CAREM regarding the solutions presented to reduce the chance of major nuclear accidents. These designs have been grouped under different names: Advanced Reactors, Second Generation Reactors, Inherently Safe Reactors, or even, Revolutionary Reactors. Every reactor fabrication firm has, at least, one project which can be placed in this category. Presently, there are two main currents of Reactor Design; Evolutionary and Revolutionary. The present work discusses characteristics of these two types of reactors, some revolutionary designs and common criteria to both types. After, these criteria are compared with CAREM reactor design. (Author) [es

  17. The international thermonuclear reactor project

    International Nuclear Information System (INIS)

    James, T.R.

    1993-01-01

    The International Thermonuclear Experimental Reactor Project is a 6-year collaborative effort involving the U.S., Europe, Japan, and the Russian Federation to produce a detailed engineering design for the next-step fusion device

  18. CANDU plant life management - An integrated approach

    International Nuclear Information System (INIS)

    Charlebois, P.; Hart, R.S.; Hopkins, J.R.

    1998-01-01

    Commercial versions of CANDU reactors were put into service starting more than 25 years ago. The first unit of Ontario Hydro's Pickering A station was put into service in 1971, and Bruce A in 1977. Most CANDU reactors, however, are only now approaching their mid-life of 15 to 20 years of operation. In particular, the first series of CANDU 6 plants which entered service in the early 1980's were designed for a 30 year life and are now approaching mid life. The current CANDU 6 design is based on a 40 year life as a result of advancement in design and materials through research and development. In order to assure safe and economic operation of these reactors, a comprehensive CANDU Plant Life Management (PLIM) program is being developed from the knowledge gained during the operation of Ontario Hydro's Pickering, Bruce, and Darlington stations, worldwide information from CANDU 6 stations, CANDU research and development programs, and other national and international sources. This integration began its first phase in 1994, with the identification of most of the critical systems structures and components in these stations, and a preliminary assessment of degradation and mechanisms that could affect their fitness for service for their planned life. Most of these preliminary assessments are now complete, together with the production of the first iteration of Life Management Plans for several of the systems and components. The Generic CANDU 6 PLIM program is now reaching its maturity, with formal processes to systematically identify and evaluate the major CSSCs in the station, and a plan to ensure that the plant surveillance, operation, and maintenance programs monitor and control component degradation well within the original design specifications essential for the plant life attainment. A Technology Watch program is being established to ensure that degradation mechanisms which could impact on plant life are promptly investigated and mitigating programs established. The

  19. The water desalination complex based on ABV-type reactor plant

    International Nuclear Information System (INIS)

    Panov, Yu.K.; Fadeev, Yu.P.; Vorobiev, V.M.; Baranaev, Yu.D.

    1997-01-01

    A floating nuclear desalination complex with two barges, one for ABV type reactor plant, with twin reactor 2 x 6 MW(e), and one for reverse osmosis desalination plant, was described. The principal specifications of the ABV type reactor plant and desalination barge were given. The ABV type reactor has a traditional two-circuit layout using an integral type reactor vessel with all mode natural convection of primary coolant. The desalted water cost was estimated to be around US $0.86 per cubic meter. R and D work has been performed and preparations for commercial production are under way. (author)

  20. TREAT [Transient Reactor Test Facility] reactor control rod scram system simulations and testing

    International Nuclear Information System (INIS)

    Solbrig, C.W.; Stevens, W.W.

    1990-01-01

    Air cylinders moving heavy components (100 to 300 lbs) at high speeds (above 300 in/sec) present a formidable end-cushion-shock problem. With no speed control, the moving components can reach over 600 in/sec if the air cylinder has a 5 ft stroke. This paper presents an overview of a successful upgrade modification to an existing reactor control rod drive design using a computer model to simulate the modified system performance for system design analysis. This design uses a high speed air cylinder to rapidly insert control rods (278 lb moved 5 ft in less than 300 msec) to scram an air-cooled test reactor. Included is information about the computer models developed to simulate high-speed air cylinder operation and a unique new speed control and end cushion design. A patent application is pending with the US Patent ampersand Trade Mark Office for this system (DOE case number S-68,622). The evolution of the design, from computer simulations thru operational testing in a test stand (simulating in-reactor operating conditions) to installation and use in the reactor, is also described. 6 figs

  1. Processes influencing cooling of reactor effluents

    International Nuclear Information System (INIS)

    Magoulas, V.E.; Murphy, C.E. Jr.

    1982-01-01

    Discharge of heated reactor cooling water from SRP reactors to the Savannah River is through sections of stream channels into the Savannah River Swamp and from the swamp into the river. Significant cooling of the reactor effluents takes place in both the streams and swamp. The majority of the cooling is through processes taking place at the surface of the water. The major means of heat dissipation are convective transfer of heat to the air, latent heat transfer through evaporation and radiative transfer of infrared radiation. A model was developed which incorporates the effects of these processes on stream and swamp cooling of reactor effluents. The model was used to simulate the effect of modifications in the stream environment on the temperature of water flowing into the river. Environmental effects simulated were the effect of changing radiant heat load, the effect of changes in tree canopy density in the swamp, the effect of total removal of trees from the swamp, and the effect of diverting the heated water from L reactor from Steel Creek to Pen Branch. 6 references, 7 figures

  2. Beryllium and lithium resource requirements for solid blanket designs for fusion reactors

    International Nuclear Information System (INIS)

    Powell, J.R.

    1975-01-01

    The lithium and beryllium requirements are analyzed for an economy of 10 6 MW(e) CTR 3 capacity using solid blanket fusion reactors. The total lithium inventory in fusion reactors is only approximately 0.2 percent of projected U. S. resources. The lithium inventory in the fusion reactors is almost entirely 6 Li, which must be extracted from natural lithium. Approximately 5 percent of natural lithium can be extracted as 6 Li. Thus the total feed of natural lithium required is approximately 20 times that actually used in fusion reactors, or approximately 4 percent of U. S. resources. Almost all of this feed is returned to the U. S. resource base after 6 Li is extracted, however. The beryllium requirements are on the order of 10 percent of projected U. S. resources. Further, the present cost of lithium and the cost of beryllium extraction could both be increased tenfold with only minor effects on CTR capital cost. Such an increase should substantially multiply the economically recoverable resources of lithium and beryllium. It is concluded that there are no lithium or beryllium resource limitations preventing large-scale implementation of solid blanket fusion reactors. (U.S.)

  3. Pressurized-water reactors

    International Nuclear Information System (INIS)

    Bush, S.H.

    1983-03-01

    An overview of the pressurized-water reactor (PWR) pressure boundary problems is presented. Specifically exempted will be discussions of problems with pumps, valves and steam generators on the basis that they will be covered in other papers. Pressure boundary reliability is examined in the context of real or perceived problems occurring over the past 5 to 6 years since the last IAEA Reliability Symposium. Issues explicitly covered will include the status of the pressurized thermal-shock problem, reliability of inservice inspections with emphasis on examination of the region immediately under the reactor pressure vessel (RPV) cladding, history of piping failures with emphasis on failure modes and mechanisms. Since nondestructive examination is the topic of one session, discussion will be limited to results rather than techniques

  4. The stand prototype of minimum power NRE reactor

    International Nuclear Information System (INIS)

    Belogurov, A.I.; Grigorenko, L.N.; Mamontov, Yu.I.; Rachuk, V.S.; Stukalov, A.I.; Konyukhov, G.V.

    1995-01-01

    For ensuring of full-scale development of nuclear rocket engine (NRE) reactor was created stand prototype (reactor IRGIT?) The main differences of its are as follows: 1) Fasteners of technologies channels contents fuel assemblies in bottom are worked out the split. It is provides possibility a distance channels change without disassembly of reactor stand prototype from stand; 2) Cooling of the vessels, the moderator, the reflector and the barrel actuate is carried out by hydrogen; 3) The lower bottom modified for organization the hydrogen efflux in the form a reactor jet; 4) Radiation defence is introduced as part of stand prototype for ensuring of serviceability of stand accessories and tests routine service; 5) Each technology channels is provided of critical nozzle; 6) Control, regulation and defence of reactor has being carried out on stand system

  5. International tokamak reactor conceptual design overview

    International Nuclear Information System (INIS)

    Stacey, W.M. Jr.

    1983-01-01

    The International Tokamak Reactor (INTOR) Workshop is an unique collaborative effort among Euratom, Japan, the USA and the USSR, under the auspices of the IAEA, to assess, define, design, construct and operate the next major experiment in the World Tokamak Program beyond the TFTR, JET, JT-60, T-15 generation. During the Zero-Phase (1979), a technical data base assessment was performed, leading to a positive assessment of feasibility. During Phase-I (1/80-6/81), a conceptual design was developed to define the concept. The programmatic objectives are that INTOR should: (1) be the maximum reasonable step beyond the TFTR, JET, JT-60, T-15 generation of tokamaks, (2) demonstrate the plasma performance required for tokamak DEMOs, (3) test the development and integration into a reactor system of those technologies required for a DEMO, (4) serve as a test facility for blanket, tritium production, materials, and plasma engineering technology, (5) test fusion reactor component reliability, (6) test the maintainability of a fusion reactor, and (7) test the factors affecting the reliability, safety and environmental acceptability of a fusion reactor. A conceptual design has been developed to define a device which is consistent with these objectives. The design concept could, with a reasonable degree of confidence, be developed into a workable engineering design of a tokamak that met the performance objectives of INTOR. There is some margin in the design to allow for uncertainty. While design solutions have been found for all of the critical issues, the overall design may not yet be optimal. (author)

  6. Neutron behavior, reactor control, and reactor heat transfer. Volume four

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Volume four covers neutron behavior (neutron absorption, how big are nuclei, neutron slowing down, neutron losses, the self-sustaining reactor), reactor control (what is controlled in a reactor, controlling neutron population, is it easy to control a reactor, range of reactor control, what happens when the fuel burns up, controlling a PWR, controlling a BWR, inherent safety of reactors), and reactor heat transfer (heat generation in a nuclear reactor, how is heat removed from a reactor core, heat transfer rate, heat transfer properties of the reactor coolant)

  7. Reactor-specific spent fuel discharge projections: 1986 to 2020

    International Nuclear Information System (INIS)

    Heeb, C.M.; Walling, R.C.; Purcell, W.L.

    1987-03-01

    The creation of five reactor-specific spent fuel data bases that contain information on the projected amounts of spent fuel to be discharged from US commercial nuclear reactors through the year 2020 is described. The data bases contain detailed spent-fuel information from existing, planned, and projected pressurized water reactors (PWR) and boiling water reactors (BWR). The projections are based on individual reactor information supplied by the US reactor owners. The basic information is adjusted to conform to Energy Information Agency (EIA) forecasts for nuclear installed capacity, generation, and spent fuel discharged. The EIA cases considered are: (1) No new orders with extended burnup, (2) No new orders with constant burnup, (3) Upper reference (which assumes extended burnup), (4) Upper reference with constant burnup, and (5) Lower reference (which assumes extended burnup). Detailed, by-reactor tables are provided for annual discharged amounts of spent fuel, for storage requirements assuming maximum-at-reactor storage, and for storage requirements assuming maximum-at-reactor plus intra-utility transshipment of spent fuel. 6 refs., 8 figs., 8 tabs

  8. Reactor science and technology: operation and control of reactors

    International Nuclear Information System (INIS)

    Qiu Junlong

    1994-01-01

    This article is a collection of short reports on reactor operation and research in China in 1991. The operation of and research activities linked with the Heavy Water Research Reactor, Swimming Pool Reactor and Miniature Neutron Source Reactor are briefly surveyed. A number of papers then follow on the developing strategies in Chinese fast breeder reactor technology including the conceptual design of an experimental fast reactor (FFR), theoretical studies of FFR thermo-hydraulics and a design for an immersed sodium flowmeter. Reactor physics studies cover a range of topics including several related to work on zero power reactors. The section on reactor safety analysis is concerned largely with the assessment of established, and the presentation of new, computer codes for use in PWR safety calculations. Experimental and theoretical studies of fuels and reactor materials for FBRs, PWRs, BWRs and fusion reactors are described. A final miscellaneous section covers Mo-Tc isotope production in the swimming pool reactor, convective heat transfer in tubes and diffusion of tritium through plastic/aluminium composite films and Li 2 SiO 3 . (UK)

  9. Nuclear power reactors

    International Nuclear Information System (INIS)

    1982-11-01

    After an introduction and general explanation of nuclear power the following reactor types are described: magnox thermal reactor; advanced gas-cooled reactor (AGR); pressurised water reactor (PWR); fast reactors (sodium cooled); boiling water reactor (BWR); CANDU thermal reactor; steam generating heavy water reactor (SGHWR); high temperature reactor (HTR); Leningrad (RMBK) type water-cooled graphite moderated reactor. (U.K.)

  10. Conceptual design study of small lead-bismuth cooled reactor

    International Nuclear Information System (INIS)

    Chikazawa, Yoshitaka; Hori, Toru; Kida, Masanori; Konomura, Mamoru

    2004-11-01

    In phase 2 of the feasibility study of commercialized fast reactor cycle systems of JNC, we make a concept of a small sodium cooled reactor for a power source of a city with various requirements, such as, safety and economical competitiveness. various reactor concepts are surveyed and a tank type reactor whose intermediate heat exchanger and primary main pumps are arranged in series is selected. In this study, a compact long life core and a simple reactor structure designs are pursued. The core type is three regional Zr concentration with one Pu enrichment core, the reactor outlet temperature achieves 550degC and the reactor electric output increases from 150 MWe to 165 MWe. The construction cost is much higher than the economical goal in the case of FOAK. But the construction cost in the case of NOAK is estimated to be 85.6% achieving the economical goal. (author)

  11. Experience in utilizing research reactors in Yugoslavia

    Energy Technology Data Exchange (ETDEWEB)

    Pop-Jordanov, J.; Raisic, N. [Boris Kidric Institute of Nuclear Sciences VINCA, Belgrade (Yugoslavia); Copic, M.; Gabrovsek, Z. [Jozef Stefan Institute Ljubljana (Yugoslavia)

    1972-07-01

    The nuclear institutes in Yugoslavia possess three research reactors. Since 1958, two heavy-water reactors have been in operation at the 'Boris Kidric' Institute, a zero-power reactor RB and a 6. 5-MW reactor RA. At the Jozef Stefan Institute, a 250-kW TRIGA Mark II reactor has been operating since 1966. All reactors are equipped with the necessary experimental facilities. The main activities based on these reactors are: (1) fundamental research in solid-state and nuclear physics; (2) R and D activities related to nuclear power program; and (3) radioisotope production. In fundamental physics, inelastic neutron scattering and diffraction phenomena are studied by means of the neutron beam tubes and applied to investigations of the structures of solids and liquids. Valuable results are also obtained in n - γ reaction studies. Experiments connected with the fuel -element development program, owing to the characteristics of the existing reactors, are limited to determination of the fuel element parameters, to studies on the purity of uranium, and to a small number of capsule irradiations. All three reactors are also used for the verification of different methods applied in the analysis of power reactors, particularly concerning neutron flux distributions, the optimization of reactor core configurations and the shielding effects. An appreciable irradiation space in the reactors is reserved for isotope production. Fruitful international co-operation has been established in all these activities, on the basis of either bilateral or multilateral arrangements. The paper gives a critical analysis of the utilization of research reactors in a developing country such as Yugoslavia. The investments in and the operational costs of research reactors are compared with the benefits obtained in different areas of reactor application. The impact on the general scientific, technological and educational level in the country is also considered. In particular, an attempt is made ro

  12. Experience in utilizing research reactors in Yugoslavia

    International Nuclear Information System (INIS)

    Pop-Jordanov, J.; Raisic, N.; Copic, M.; Gabrovsek, Z.

    1972-01-01

    The nuclear institutes in Yugoslavia possess three research reactors. Since 1958, two heavy-water reactors have been in operation at the 'Boris Kidric' Institute, a zero-power reactor RB and a 6. 5-MW reactor RA. At the Jozef Stefan Institute, a 250-kW TRIGA Mark II reactor has been operating since 1966. All reactors are equipped with the necessary experimental facilities. The main activities based on these reactors are: (1) fundamental research in solid-state and nuclear physics; (2) R and D activities related to nuclear power program; and (3) radioisotope production. In fundamental physics, inelastic neutron scattering and diffraction phenomena are studied by means of the neutron beam tubes and applied to investigations of the structures of solids and liquids. Valuable results are also obtained in n - γ reaction studies. Experiments connected with the fuel -element development program, owing to the characteristics of the existing reactors, are limited to determination of the fuel element parameters, to studies on the purity of uranium, and to a small number of capsule irradiations. All three reactors are also used for the verification of different methods applied in the analysis of power reactors, particularly concerning neutron flux distributions, the optimization of reactor core configurations and the shielding effects. An appreciable irradiation space in the reactors is reserved for isotope production. Fruitful international co-operation has been established in all these activities, on the basis of either bilateral or multilateral arrangements. The paper gives a critical analysis of the utilization of research reactors in a developing country such as Yugoslavia. The investments in and the operational costs of research reactors are compared with the benefits obtained in different areas of reactor application. The impact on the general scientific, technological and educational level in the country is also considered. In particular, an attempt is made ro

  13. Research reactors

    International Nuclear Information System (INIS)

    Merchie, Francois

    2015-10-01

    This article proposes an overview of research reactors, i.e. nuclear reactors of less than 100 MW. Generally, these reactors are used as neutron generators for basic research in matter sciences and for technological research as a support to power reactors. The author proposes an overview of the general design of research reactors in terms of core size, of number of fissions, of neutron flow, of neutron space distribution. He outlines that this design is a compromise between a compact enough core, a sufficient experiment volume, and high enough power densities without affecting neutron performance or its experimental use. The author evokes the safety framework (same regulations as for power reactors, more constraining measures after Fukushima, international bodies). He presents the main characteristics and operation of the two families which represent almost all research reactors; firstly, heavy water reactors (photos, drawings and figures illustrate different examples); and secondly light water moderated and cooled reactors with a distinction between open core pool reactors like Melusine and Triton, pool reactors with containment, experimental fast breeder reactors (Rapsodie, the Russian BOR 60, the Chinese CEFR). The author describes the main uses of research reactors: basic research, applied and technological research, safety tests, production of radio-isotopes for medicine and industry, analysis of elements present under the form of traces at very low concentrations, non destructive testing, doping of silicon mono-crystalline ingots. The author then discusses the relationship between research reactors and non proliferation, and finally evokes perspectives (decrease of the number of research reactors in the world, the Jules Horowitz project)

  14. Fast breeder reactor-block antiseismic design and verification

    International Nuclear Information System (INIS)

    Martelli, A.; Forni, M.

    1988-02-01

    The Specialists' Meeting on ''Fast Breeder Reactor-Block Antiseismic Design and Verification'' was organized by the ENEA Fast Reactor Department in co-operation with the International Working Group (IWGFR) of the International Atomic Energy Agency (IAEA), according to the recommendations of the 19th IAEA/IWGFR Meeting. It was held in Bologna, at the Headquarters of the ENEA Fast Reactor Department, on October 12-15, 1987, in the framework of the Celebrations for the Ninth Centenary of the Bologna University. The proceedings of the meeting consists of three parts. Part 1 contains the introduction and general comments, the agenda of the meeting, session summaries, conclusions and recommendations and the list of participants. Part 2 contains 8 status reports of Member States participating in the Working Group. Contributed papers were published in Part 3 and were further subdivided into 5 sessions as follows: whole reactor-block analysis (4 papers); whole reactor-block analysis (sloshing and buckling, seismic isolation effects) (8 papers); detailed core analysis (6 papers); shutdown systems and core structural and functional verifications (6 papers); component and piping analysis (7 papers). A separate abstract was prepared for each of the 8 status reports and 31 contributed papers. Refs, figs and tabs

  15. To question of NPP power reactor choice for Kazakhstan

    International Nuclear Information System (INIS)

    Batyrbekov, G.A.; Makhanov, Y.M.; Reznikova, R.A.; Sidorenco, A.V.

    2004-01-01

    Full text: The requirements to NPP power reactors that will be under construction in Kazakhstan are proved and given in the report. A comparative analysis of the most advanced projects of power reactors with light and heavy water under pressure of large, medium and low power is carried out. Different reactors have been considered as follows: 1. Reactors with high-power (700 MW(el) and up) such as EPR, French - German reactor; CANDU-9, Canadian heavy-water reactor; System 80+, developed by ABB Combustion Engineering company, USA; KNGR, Korean reactor of the next generation; APWR, Japanese advanced reactor; WWER-1000 (V-392) - development of Atomenergoproect /Gydropress, Russian Federation; EP 1000, European passive reactor. 2. Reactors with medium power (300 MW (el) - 700 MW (el): AP-600, passive PWR of the Westinghouse company; CANDU-6, Canadian heavy-water reactor; AC-600, Chinese passive PWR; WWER-640, Russian passive reactor; MS-600 Japanese reactor of Mitsubishi Company; KSNP-600, South Korean reactor. 3. Reactors with low power (a few MW(el)- 300 MW(el)): IRIS, reactor of IV generation, developed by the International Corporation of 13 organizations from 7 countries, SMART, South Korean integrated reactor; CAREM, Argentina integrated reactor; MRX, Japanese integrated reactor; 'UNITERM', Russian NPP with integrated reactor, development of NIKIET; AHEC-80, Russian NPP, developed by OKBM. A comparison of the projects of the above-mentioned power reactors was carried out with respect to 15 criteria of nuclear, radiating, ecological safety and economic competitiveness, developed especially for this case. Data on a condition and prospects of power production and power consumption, stations and networks in Kazakhstan necessary for the choice of projects of NPP reactors for Kazakhstan are given. According to the data a balance of power production and power consumption as a whole in the country was received at the level of 59 milliard kw/h. However, strong dis balance

  16. To question of NPP power reactor choice for Kazakhstan

    International Nuclear Information System (INIS)

    Batyrbekov, G.A.; Makhanov, Y.M.; Reznikova, R.A.; Sidorenco, A.V.

    2004-01-01

    The requirements to NPP power reactors that will be under construction in Kazakhstan are proved and given in the report. A comparative analysis of the most advanced projects of power reactors with light and heavy water under pressure of large, medium and low power is carried out. Different reactors have been considered as follows: 1. Reactors with high-power (700 MW(el) and up) such as EPR, French - German reactor; CANDU-9, Canadian heavy-water reactor; System 80+, developed by ABB Combustion Engineering company, USA; KNGR, Korean reactor of the next generation; APWR, Japanese advanced reactor; WWER-1000 (V-392) - development of Atomenergoproect /Gydropress, Russian Federation; EP 1000, European passive reactor. 2. Reactors with medium power (300 MW (el) - 700 MW (el): AP-600, passive PWR of the Westinghouse company; CANDU-6, Canadian heavy-water reactor; AC-600, Chinese passive PWR; WWER-640, Russian passive reactor; MS-600 Japanese reactor of Mitsubishi Company; KSNP-600, South Korean reactor. 3. Reactors with low power (a few MW(el)- 300 MW(el)): IRIS, reactor of IV generation, developed by the International Corporation of 13 organizations from 7 countries, SMART, South Korean integrated reactor; CAREM, Argentina integrated reactor; MRX, Japanese integrated reactor; 'UNITERM', Russian NPP with integrated reactor, development of NIKIET; AHEC-80, Russian NPP, developed by OKBM. A comparison of the projects of the above-mentioned power reactors was carried out with respect to 15 criteria of nuclear, radiating, ecological safety and economic competitiveness, developed especially for this case. Data on a condition and prospects of power production and power consumption, stations and networks in Kazakhstan necessary for the choice of projects of NPP reactors for Kazakhstan are given. According to the data a balance of power production and power consumption as a whole in the country was received at the level of 59 milliard kw/h. However, strong dis balance in the

  17. Fast breeder reactor research

    International Nuclear Information System (INIS)

    1975-01-01

    reactors of the future, the body of research aimed at developing liquid metal cooled fast reactors, national plans for work in 1976 on developing fast reactors - these were some of the topics discussed in connection with the national programmes. The development of power reactors involves a wide range of problems in the fields of nuclear and reactor physics, the thermophysics, chemistry, physics and technology of the cooling system, structural materials and nuclear fuel, the fabrication of reliable fuel elements and operating equipment, reactor monitoring and control, spent fuel reprocessing, the economics of constructing fast power reactors, nuclear safety, etc. The IWGFR, as at previous meetings, therefore paid great attention to the matter of holding international specialists' meetings. The working group recommended that the IAEA should organize the following IWGFR meetings in 1976: (1) In-Service Inspection and Monitoring (Bensberg, FRG, March 1976). (2) Cavitation in Sodium and Studies of Analogy with Water as Compared to Sodium (Cadarache, France, April 1976). (3) High Temperature Structural Design Technology (United States, May 1976) (4) Aerosol Formation, Vapour Deposits and Sodium Vapour Trapping (France, September-December 1976). The Group welcomed the IAEA's proposal to hold specialists' meetings on 'Fast Reactor Instrumentation' and 'Fuel Reprocessing and Recycling Techniques' within the framework of the Agency's programme of working groups in 1976. After discussing questions of co-ordinating and organizing international conferences on fast reactors, the IWGFR agreed to send representatives to the joint meeting of the American Nuclear Society and the American Institute of Metallurgical Engineers on 'Liquid Metal Technology', to be held at Champion, Pennsylvania, U.S.A. from 3-6 May 1976, and recommended that the IAEA should organize an international symposium on the 'Design, Construction and Operating Experience of Demonstration Fast Power Reactors' at Bologna

  18. Advanced fuels for nuclear fusion reactors

    International Nuclear Information System (INIS)

    McNally, J.R. Jr.

    1974-01-01

    Should magnetic confinement of hot plasma prove satisfactory at high β (16 πnkT//sub B 2 / greater than 0.1), thermonuclear fusion fuels other than D.T may be contemplated for future fusion reactors. The prospect of the advanced fusion fuels D.D and 6 Li.D for fusion reactors is quite promising provided the system is large, well reflected and possesses a high β. The first generation reactions produce the very active, energy-rich fuels t and 3 He which exhibit a high burnup probability in very hot plasmas. Steady state burning of D.D can ensue in a 60 kG field, 5 m reactor for β approximately 0.2 and reflectivity R/sub mu/ = 0.9 provided the confinement time is about 38 sec. The feasibility of steady state burning of 6 Li.D has not yet been demonstrated but many important features of such systems still need to be incorporated in the reactivity code. In particular, there is a need for new and improved nuclear cross section data for over 80 reaction possibilities

  19. Licensed operating reactors. Status summary report, data as of May 31, 1986. Volume 10, Number 6

    International Nuclear Information System (INIS)

    1986-08-01

    This report is divided into three sections: the first contains monthly highlights and statistics for commercial operating units, and errata from previously reported data; the second is a compilation of detailed information on each unit, provided by NRC Regional Offices, IE Headquarters and the Utilities; and the third section is an appendix for miscellaneous information such as spent fuel storage capability, reactor years of experience and non-power reactors in the United States

  20. Annual report, 1980

    International Nuclear Information System (INIS)

    1980-01-01

    Operations of Ontario Hydro, one of North America's largest utilities, for the year 1980 are described. A new energy-use strategy was evolved during 1980 which included maximizing use of electricity generated from indigenous sources to substitute for imported fossil fuels. Due to the consistently outstanding performance of the utility's nuclear plants at Pickering and Bruce, nuclear power supplied 34 percent of the total energy generated, up three percent from 1979. This is second only to hyraulic generation. Ontario Hydro's reactors, four of which led the world's power reactors with capacities exceeding 500 MW in overall capacity factor, continued to provide reliable generation. Ontario Hydro is a publicly-owned financially self-supporting utility. During 1980 steps were taken to reduce the difference in rates between rural and urban customers. Average rate increases to be implemented in January 1981 were 9.3 percent for municipal utilities, 9.6 percent to direct industrial customers, and 11.2 percent for direct rural customers. The average revenue from residential users was $0.0364 per kwh. Revenue was $2.8 billion on assets of $15.6 billion. (O.T.)