WorldWideScience

Sample records for bridgman technique determination

  1. Multielemental segregation analysis of the thallium bromide impurities purified by repeated Bridgman technique

    International Nuclear Information System (INIS)

    Santos, Robinson A. dos; Hamada, Margarida M.; Costa, Fabio E. da; Gennari, Roseli F.; Martins, Joao F.T.; Marcondes, Renata M.; Mesquita, Carlos H. de

    2011-01-01

    TlBr crystals were purified and grown by the repeated Bridgman method from two commercial TlBr salts and characterized to be used as radiation detectors. To evaluate the purification efficiency, measurements of the impurity concentration were made after each growth, analyzing the trace impurities by inductively coupled plasma mass spectroscopy (ICP-MS). A significant decrease of the impurity concentration resulting from the purification number was observed. To evaluate the crystal as a radiation semiconductor detector, measurements of its resistivity and gamma-ray spectroscopy were carried out. The radiation response depended on the crystal purity. The repeated Bridgman technique improved the TlBr crystal quality used as a radiation detector. A compartmental model was proposed to fit the impurity concentration as a function of the repetition number of the Bridgman growth. (author)

  2. Yield strength, shear stress and toughness of YBCO samples textured by Bridgman technique

    International Nuclear Information System (INIS)

    Roa, J J; Capdevila, X G; Martinez, M; Segarra, M; Jimenez-Pique, E

    2008-01-01

    Mechanical properties of the orthorhombic phase of YBa 2 Cu 3 O 7-δ (Y-123) at room temperature have been investigated at different applied loads using nanoindentation technique. The study was carried out for several monodomains on the (001) planes for textured Bridgman samples with dispersed Y 2 BaCuO 5 (Y-211) particles as pinning centers. The yield strength (σ ys ), shear stress (τ m ) and toughness (K IC ) of Y123/Y211composite was determined at different applied loads. First and second mechanical properties have been calculated though the Hertz equations and the last one with Lawn et al. equations. Finally, the ultra-low imprints obtained by nanoindentation have been correlated with parameters obtained by Field Emission Scanning Electron Microscope (FE-SEM)

  3. Bridgman's concern

    International Nuclear Information System (INIS)

    Graham, R.A.

    1993-01-01

    In 1956 P.W. Bridgman published a letter to the editor in the Journal of Applied Physics reporting results of electrical resistance measurements on iron under static high pressure. The work was undertaken to verify the existence of a polymorphic phase transition at 130 kbar (13 GPa) reported in the same journal and year by the Los Alamos authors, Bancroft, Peterson and Minshall for high pressure, shock-compression loading. In his letter, Bridgman reported that he failed to find any evidence for the transition. Further, he raised some fundamental concerns as to the state of knowledge of shock-compression processes in solids. Later it was determined that Bridgman's static pressure scale was in error, and the shock observations became the basis for calibration of pressure values in static high pressure apparatuses. In spite of the error in pressure scales, Bridgman's concerns on descriptions of shock-compression processes were perceptive and have provided the basis for subsequent fundamental studies of shock-compressed solids. The present paper, written in response to receipt of the 1993 American Physical Society Shock-Compression Science Award, provides a brief contemporary assessment of those shock-compression issues which were the basis of Bridgman's 1956 concerns

  4. Thermoluminescence kinetic features of Lithium Iodide (LiI) single crystal grown by vertical Bridgman technique

    Science.gov (United States)

    Daniel, D. Joseph; Kim, H. J.; Kim, Sunghwan; Khan, Sajid

    2017-08-01

    Single crystal of pure Lithium Iodide (LiI) has been grown from melt by using the vertical Bridgman technique. Thermoluminescence (TL) Measurements were carried out at 1 K/s following X-ray irradiation. The TL glow curve consists of a dominant peak at (peak-maximum Tm) 393 K and one low temperature peak of weaker intensity at 343 K. The order of kinetics (b), activation energy (E), and the frequency factor (S) for a prominent TL glow peak observed around 393 K for LiI crystals are reported for the first time. The peak shape analysis of the glow peak indicates the kinetics to be of the first order. The value of E is calculated using various standard methods such as initial rise (IR), whole glow peak (WGP), peak shape (PS), computerized glow curve deconvolution (CGCD) and Variable Heating rate (VHR) methods. An average value of 1.06 eV is obtained in this case. In order to validate the obtained parameters, numerically integrated TL glow curve has been generated using experimentally determined kinetic parameters. The effective atomic number (Zeff) for this material was determined and found to be 52. X-ray induced emission spectra of pure LiI single crystal are studied at room temperature and it is found that the sample exhibit sharp emission at 457 nm and broad emission at 650 nm.

  5. Bridgman growth and assessment of CdTe and CdZnTe using the accelerated crucible rotation technique

    Energy Technology Data Exchange (ETDEWEB)

    Capper, P.; Harris, J.E.; O' Keefe, E.; Jones, C.L.; Ard, C.K.; Mackett, P.; Dutton, D. (Philips Infrared Defence Components, Southampton (United Kingdom))

    1993-01-30

    The Bridgman growth process for CdTe has been extended by applying the accelerated crucible rotation technique (ACRT). Modelling using ACRT has been extended to the 50 mm diameter required to produce grains large enough to yield CdTe(and Cd[sub 0.96]Zn[sub 0.04]Te) slices suitable for use in liquid phase epitaxy of Cd[sub x]Hg[sub 1-x]Te (CMT) layers. Two regimes are identified: ACRT parameter combinations which give maximum fluid velocities and that which maintains stable Ekman flow. Growth of crystals shows that larger single crystal regions are obtained when the Ekman flow is stable. Effects of changing the ampoule base shape have also been investigated. Techniques have been developed to produce 20 mm x 30 mm substrates oriented oriented close to the (111) direction. Assessment of these samples has included IR transmission, IR microscopy, defect etching, X-ray topography and X-ray diffraction curve width measurements. Chemical analyses have been carried out to determine impurity levels and matrix element distributions. Good quality CMT epitaxial layers, as demonstrated by good surface topography, electrical data and chemical analyses, have been grown onto material produced in this study. (orig.).

  6. Characteristics evaluation of stilbene single crystal grown by vertical bridgman technique

    International Nuclear Information System (INIS)

    Jo, Kwang Ho

    2012-02-01

    As the nature of organic scintillator, stilbene single crystal's decay time is only a couple of nano seconds, which makes it suitable for fast neutron detection. However, the entire amount of stilbene single crystal being used relies on import currently. As the necessity of fast neutron detection equipment such as KSTAR and Sodium-cooled Fast Reactor system increases, the goal is to have our own domestic technology through the growth of stilbene single crystal. The emission wavelength of grown stilbene single crystal is confirmed, and the property of grown stilbene single crystal is assessed compared to commercial stilbene (Ukraine ISMA research center) through gamma ray and neutron tests. In this research, we have grown stilbenes through Bridgman technique, and obtained three stilbenes out of two amples. (Two ones of Φ 30 mm x 15 mm, and Φ 40 mm x 17 mm from the first ample, and size of Φ 25 mm x 13 mm from the other) The grown stilbene's emission wavelength and inherent property of stilbene are confirmed. As the result of gamma ray test, we have confirmed linearity of grown stilbene's scintillator, and the relative light yield ratio is proven 101% efficiency to reference stilbene. Neutron detection efficiency of the three stilbenes amounts to 80% of reference stilbene, and FOM of them is 108% efficiency to reference stilbene's one. Although Ukraine ISMA research center still holds a dominant position with world-class efficiency and performance of its stilbene, we expect to produce a better stilbene with our domestic technology development. Through this, fast neutron detection technique can be obtained, which opens up an opportunity to be used not only in neutron monitoring system in nuclear fusion reactor, but also in alternative measurement technique as the unit price of He-3 increases recently

  7. Electrical properties of Au/CdZnTe/Au detectors grown by the boron oxide encapsulated Vertical Bridgman technique

    Energy Technology Data Exchange (ETDEWEB)

    Turturici, A.A. [Dipartimento di Fisica e Chimica, Università di Palermo, Viale delle Scienze, Edificio 18, Palermo 90128 (Italy); Abbene, L., E-mail: leonardo.abbene@unipa.it [Dipartimento di Fisica e Chimica, Università di Palermo, Viale delle Scienze, Edificio 18, Palermo 90128 (Italy); Gerardi, G. [Dipartimento di Fisica e Chimica, Università di Palermo, Viale delle Scienze, Edificio 18, Palermo 90128 (Italy); Benassi, G. [due2lab s.r.l., Via Paolo Borsellino 2, Scandiano, 42019 Reggio Emilia (Italy); Bettelli, M.; Calestani, D. [IMEM/CNR, Parco Area delle Scienze 37/A, Parma 43100 (Italy); Zambelli, N. [due2lab s.r.l., Via Paolo Borsellino 2, Scandiano, 42019 Reggio Emilia (Italy); Raso, G. [Dipartimento di Fisica e Chimica, Università di Palermo, Viale delle Scienze, Edificio 18, Palermo 90128 (Italy); Zappettini, A. [IMEM/CNR, Parco Area delle Scienze 37/A, Parma 43100 (Italy); Principato, F. [Dipartimento di Fisica e Chimica, Università di Palermo, Viale delle Scienze, Edificio 18, Palermo 90128 (Italy)

    2016-09-11

    In this work we report on the results of electrical characterization of new CdZnTe detectors grown by the Boron oxide encapsulated Vertical Bridgman technique (B-VB), currently produced at IMEM-CNR (Parma, Italy). The detectors, with gold electroless contacts, have different thicknesses (1 and 2.5 mm) and the same electrode layout, characterized by a central anode surrounded by a guard-ring electrode. Investigations on the charge transport mechanisms and the electrical contact properties, through the modeling of the measured current–voltage (I–V) curves, were performed. Generally, the detectors are characterized by low leakage currents at high bias voltages even at room temperature: 34 nA/cm{sup 2} (T=25 °C) at 10,000 V/cm, making them very attractive for high flux X-ray measurements, where high bias voltage operation is required. The Au/CdZnTe barrier heights of the devices were estimated by using the interfacial layer-thermionic-diffusion (ITD) model in the reverse bias voltage range. Comparisons with CdZnTe detectors, grown by Traveling Heater Method (THM) and characterized by the same electrode layout, deposition technique and resistivity, were also performed.

  8. Growth of langasite via Bridgman technique along [ 0 0 0 1], [ 2 1¯ 1¯ 0] and [ 0 1 1¯ 1] for piezoelectric applications

    Science.gov (United States)

    Uda, Satoshi; Inaba, Hitoshi; Harada, Jiro; Hoshikawa, Keigo

    2004-10-01

    2-inch langasite (La 3Ga 5SiO 14) single crystals were grown for the first time via a vertical Bridgman method, assisted by the accelerated crucible rotation technique (ACRT) along [ 0 0 0 1] ( Z-axis), [ 2 1¯ 1¯ 0] ( X-axis) and [ 0 1 1¯ 1] (54°-rotated Y-axis) for piezoelectric applications. Because of the possible liquid immiscibility, incongruency and segregation, secondary phases other than langasite are formed during growth. The mode of occurrence of these phases was closely related to the interface instability that was specific to the growth direction. The formation of inclusions consisting of lanthanum gallate (LaGaO 3), aligned parallel to ( 0 1 1¯ 0), was associated with the constitutional supercooling. The residual products during the terminal transient were the mixture of gallium oxide (Ga 2O 3) and lanthanum gallate (LaGaO 3) or the mixture of gallium oxide and lanthanum silicate (La 2Si 2O 7) reflecting the position of the initial melt, relative to the tie line connecting the langasite solid solution with gallium oxide in the system of La 2O 3-Ga 2O 3-SiO 2. The homogeneity of the grown crystal was evaluated by the distribution of SAW velocities of the devices fabricated on the ( 0 1 1¯ 0) wafer, as well as by the uniformity of d-spacing of 0 5 5¯ 5.

  9. X-ray response of CdZnTe detectors grown by the vertical Bridgman technique: Energy, temperature and high flux effects

    Energy Technology Data Exchange (ETDEWEB)

    Abbene, L., E-mail: leonardo.abbene@unipa.it [Dipartimento di Fisica e Chimica (DiFC), Università di Palermo, Viale delle Scienze, Edificio 18, Palermo 90128 (Italy); Gerardi, G.; Turturici, A.A.; Raso, G. [Dipartimento di Fisica e Chimica (DiFC), Università di Palermo, Viale delle Scienze, Edificio 18, Palermo 90128 (Italy); Benassi, G. [due2lab s.r.l., Via Paolo Borsellino 2, Scandiano, Reggio Emilia 42019 (Italy); Bettelli, M. [IMEM/CNR, Parco Area delle Scienze 37/A, Parma 43100 (Italy); Zambelli, N. [due2lab s.r.l., Via Paolo Borsellino 2, Scandiano, Reggio Emilia 42019 (Italy); Zappettini, A. [IMEM/CNR, Parco Area delle Scienze 37/A, Parma 43100 (Italy); Principato, F. [Dipartimento di Fisica e Chimica (DiFC), Università di Palermo, Viale delle Scienze, Edificio 18, Palermo 90128 (Italy)

    2016-11-01

    Nowadays, CdZnTe (CZT) is one of the key materials for the development of room temperature X-ray and gamma ray detectors and great efforts have been made on both the device and the crystal growth technologies. In this work, we present the results of spectroscopic investigations on new boron oxide encapsulated vertical Bridgman (B-VB) grown CZT detectors, recently developed at IMEM-CNR Parma, Italy. Several detectors, with the same electrode layout (gold electroless contacts) and different thicknesses (1 and 2.5 mm), were realized: the cathode is a planar electrode covering the detector surface (4.1×4.1 mm{sup 2}), while the anode is a central electrode (2×2 mm{sup 2}) surrounded by a guard-ring electrode. The detectors are characterized by electron mobility-lifetime product (µ{sub e}τ{sub e}) values ranging between 0.6 and 1·10{sup −3} cm{sup 2}/V and by low leakage currents at room temperature and at high bias voltages (38 nA/cm{sup 2} at 10000 V/cm). The spectroscopic response of the detectors to monochromatic X-ray and gamma ray sources ({sup 109}Cd, {sup 241}Am and {sup 57}Co), at different temperatures and fluxes (up to 1 Mcps), was measured taking into account the mitigation of the effects of incomplete charge collection, pile-up and high flux radiation induced polarization phenomena. A custom-designed digital readout electronics, developed at DiFC of University of Palermo (Italy), able to perform a fine pulse shape and height analysis even at high fluxes, was used. At low rates (200 cps) and at room temperature (T=25 °C), the detectors exhibit an energy resolution FWHM around 4% at 59.5 keV, for comparison an energy resolution of 3% was measured with Al/CdTe/Pt detectors by using the same electronics (A250F/NF charge sensitive preamplifier, Amptek, USA; nominal ENC of 100 electrons RMS). At high rates (750 kcps), energy resolution values of 7% and 9% were measured, with throughputs of 2% and 60% respectively. No radiation polarization phenomena were

  10. Characterization of secondary phases in modified vertical bridgman growth czt

    Energy Technology Data Exchange (ETDEWEB)

    Duff, Martine

    2009-07-10

    CdZnTe or 'CZT' crystals are highly suitable for use as a room temperature based spectrometer for the detection and characterization of gamma radiation. Over the last decade, the methods for growing high quality CZT have improved the quality of the produced crystals however there are material features that can influence the performance of these materials as radiation detectors. For example, various structural heterogeneities within the CZT crystals, such as twinning, pipes, grain boundaries (polycrystallinity), and secondary phases (SP) can have a negative impact on the detector performance. In this study, a CZT material was grown by the modified vertical Bridgman growth (MVB) method with zone leveled growth without excess Te in the melt. Visual observations of material from the growth of this material revealed significant voids and SP. Three samples from this material was analyzed using various analytical techniques to evaluate its electrical properties, purity and detector performance as radiation spectrometers and to determine the morphology, dimension and elemental/structural composition of one of the SP in this material. This material was found to have a high resistivity but poor radiation spectrometer performance. It had SP that were rich in polycrystalline aluminum oxide (Al{sub 2}O{sub 3}), metallic Te and polycrystalline CdZnTe and 15 to 50 {micro}m in diameter. Bulk elemental analyses of sister material from elsewhere in the boule did not contain high levels of Al so there is considerable elemental impurity heterogeneity within the boule from this growth.

  11. Characterization of secondary phases in modified vertical bridgman growth czt

    International Nuclear Information System (INIS)

    Duff, Martine

    2009-01-01

    CdZnTe or 'CZT' crystals are highly suitable for use as a room temperature based spectrometer for the detection and characterization of gamma radiation. Over the last decade, the methods for growing high quality CZT have improved the quality of the produced crystals however there are material features that can influence the performance of these materials as radiation detectors. For example, various structural heterogeneities within the CZT crystals, such as twinning, pipes, grain boundaries (polycrystallinity), and secondary phases (SP) can have a negative impact on the detector performance. In this study, a CZT material was grown by the modified vertical Bridgman growth (MVB) method with zone leveled growth without excess Te in the melt. Visual observations of material from the growth of this material revealed significant voids and SP. Three samples from this material was analyzed using various analytical techniques to evaluate its electrical properties, purity and detector performance as radiation spectrometers and to determine the morphology, dimension and elemental/structural composition of one of the SP in this material. This material was found to have a high resistivity but poor radiation spectrometer performance. It had SP that were rich in polycrystalline aluminum oxide (Al 2 O 3 ), metallic Te and polycrystalline CdZnTe and 15 to 50 (micro)m in diameter. Bulk elemental analyses of sister material from elsewhere in the boule did not contain high levels of Al so there is considerable elemental impurity heterogeneity within the boule from this growth

  12. Reactor vital equipment determination techniques

    International Nuclear Information System (INIS)

    Bott, T.F.; Thomas, W.S.

    1983-01-01

    The Reactor Vital Equipment Determination Techniques program at the Los Alamos National Laboratory is discussed. The purpose of the program is to provide the Nuclear Regulatory Commission (NRC) with technical support in identifying vital areas at nuclear power plants using a fault-tree technique. A reexamination of some system modeling assumptions is being performed for the Vital Area Analysis Program. A short description of the vital area analysis and supporting research on modeling assumptions is presented. Perceptions of program modifications based on the research are outlined, and the status of high-priority research topics is discussed

  13. Numerical investigation of thermal and residual stress of sapphire during c-axis vertical Bridgman growth process considering the solidification history effect

    Science.gov (United States)

    Hwang, Ji Hoon; Lee, Young Cheol; Lee, Wook Jin

    2018-01-01

    Sapphire single crystals have been highlighted for epitaxial of gallium nitride films in high-power laser and light emitting diode industries. In this study, the evolution of thermally induced stress in sapphire during the vertical Bridgman crystal growth process was investigated using a finite element model that simplified the real Bridgman process. A vertical Bridgman process of cylindrical sapphire crystal with a diameter of 50 mm was considered for the model. The solidification history effect during the growth was modeled by the quite element technique. The effects of temperature gradient, seeding interface shape and seeding position on the thermal stress during the process were discussed based on the finite element analysis results.

  14. Meniscus Shapes in Detached Bridgman Growth

    Science.gov (United States)

    Volz, M. P.; Mazuruk, K

    2010-01-01

    In detached Bridgman crystal growth, most of the melt is in contact with the ampoule wall, but the crystal is separated from the wall by a small gap, typically 1-100 micrometers. A liquid free surface, or meniscus, bridges across this gap at the position of the melt-crystal interface. Meniscus shapes have been calculated for the case of detached Bridgman growth in cylindrical ampoules by solving the Young-Laplace equation. Key parameters affecting meniscus shapes are the growth angle, contact angle of the meniscus to the ampoule wall, the pressure differential across the meniscus, and the Bond number, a measure of the ratio of gravitational to capillary forces. In general, for specified values of growth and contact angles, solutions exist only over a finite range of pressure differentials. For intermediate values of the Bond number, there are multiple solutions to the Young-Laplace equations. There are also cases where, as a function of pressure differential, existence intervals alternate with intervals where no solutions exist. The implications of the meniscus shape calculations on meniscus stability are discussed.

  15. A simplified technique for shakedown load determination

    International Nuclear Information System (INIS)

    Abdalla, H.F.; Younan, M.Y.A.; Megahed, M.M.

    2005-01-01

    In this paper a simple technique is presented to determine the limit shakedown load of a structure or a component using the finite element method. Through the proposed technique, the limit shakedown load is determined without performing time consuming cyclic loading simulations or iterative elastic techniques. Instead, it is determined by performing only two analyses namely, an elastic analysis and an elastic-plastic analysis. By extracting the results of the two analyses, the limit shakedown load of the structure is determined through the calculation of the residual stresses. The technique is applied and verified using two bench mark shakedown problems namely: the two-bar structure subjected to constant axial force and cyclic thermal loading, and the Bree cylinder subjected to constant internal pressure and cyclic high heat fluxes across its wall. The results of the proposed technique showed very good correlation with the, analytically determined, Bree diagrams of both structures. Moreover, the outcomes of the proposed technique showed very good results in comparison to full cyclic loading elasto-plastic finite element simulations of both structures. (authors)

  16. Precise electrical transport measurements by using Bridgman type pressure cell at low temperature

    Energy Technology Data Exchange (ETDEWEB)

    Oishi, Takayuki [Division of Civil and Enviromental Engineering, Kanazawa University, Kakuma-machi, Kanazawa 920-1192 (Japan); Ohashi, Masashi [Faculty of Environmental Design, Kanazawa University, Kakuma-machi, Kanazawa 920-1192 (Japan)

    2010-03-01

    We report a technique for the precise measurement of the electrical resisivity under high pressure at low temperature by using Bridgman anvils made of tungsten carbide. Quasi-hydrostatic pressure is generated up to {approx}15 GPa in the relatively large working space which allows the use of large specimens and simple experimental procedures rather than using a standard diamond anvil cell. The application is demonstrated by the measurements of the electrical resistivity of lead in order to describe the effect of pressure on the superconducting transition.

  17. Precise electrical transport measurements by using Bridgman type pressure cell at low temperature

    International Nuclear Information System (INIS)

    Oishi, Takayuki; Ohashi, Masashi

    2010-01-01

    We report a technique for the precise measurement of the electrical resisivity under high pressure at low temperature by using Bridgman anvils made of tungsten carbide. Quasi-hydrostatic pressure is generated up to ∼15 GPa in the relatively large working space which allows the use of large specimens and simple experimental procedures rather than using a standard diamond anvil cell. The application is demonstrated by the measurements of the electrical resistivity of lead in order to describe the effect of pressure on the superconducting transition.

  18. Determination of hydrogen content by neutron techniques

    International Nuclear Information System (INIS)

    Santisteban, J.R.; Granada, J.R.; Mayer, R.E.

    1997-01-01

    The commonly available techniques for the determination of hydrogen dissolved in solids are usually destructive from the point of view of the sample. A new, nondestructive method for this kind of measurements has been developed at our laboratory, with the requirement of improved sensitivity for massive samples. This scattering method is based on the use of epithermal neutrons, and has been implemented through the design and construction of a spectrometer dedicated to that task. In addition, the traditional transmission method has been employed to determine hydrogen content in metals, using the full sub thermal and thermal neutron energy ranges. A pulsed neutron source based on an electron LINAC is employed, together with time-of-flight techniques. In this work we will present some results illustrative of the sensitivity achieved by these neutron techniques in different systems and for a wide range of hydrogen concentrations. (author) [es

  19. Nonlinear optical activity in Bridgman growth layered compounds

    Energy Technology Data Exchange (ETDEWEB)

    Miah, M.I., E-mail: m.miah@griffith.edu.au [Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Brisbane, QLD 4111 (Australia); Biomolecular and Physical Sciences, Griffith University, Nathan, Brisbane, QLD 4111 (Australia); Department of Physics, University of Chittagong, Chittagong 4331 (Bangladesh)

    2010-02-15

    Layered semiconductor compound CdI{sub 2} has been grown with the Bridgman technique and studied by nonlinear transmittance spectroscopy. The optical absorption in CdI{sub 2} shows a nonlinear transmission of the incident laser power (P{sub 0}) within a lower power limit. The transmission, however, is found to saturate at high powers, giving a clamped output. The value of the incident power (P{sub 0C}) at which clamping starts is also found to depend on the crystal temperature (T{sub L}). The values of P{sub OC} ranges from 55 to 65 MW cm{sup -2} for T{sub L} = 4.2-180 K. The dynamic range (D{sub R}) as a function of T{sub L} is calculated and the values are found to range from D{sub R} = 2 to 1.6. The optical limiting mechanisms are discussed. The two-photon absorption (TPA) coefficient ({beta}) of the optical nonlinear process in CdI{sub 2} is estimated. The values are found to be within a range from {beta} = 47 to 25 cm GW{sup -1} and be decreasing with increasing T{sub L}. As expected for the TPA process, the experimental data within a certain range follows the linear relation: log (P{sub 0}/P{sub T}) = A{sub G} + {Omega}(P{sub 0} - P{sub T}), where P{sub T} is the transmitted power, A{sub G} is the absorbance of the ground state and {Omega} is a constant depending on the absorption cross-section and the relaxation time. The values of A{sub G} and {Omega} estimated from the fits to the measured data vary with T{sub L}. The findings resulting from this investigation might have potential applications in optical sensors protection.

  20. P. W. Bridgman's contributions to the foundations of shock compression of condensed matter

    Energy Technology Data Exchange (ETDEWEB)

    Nellis, W J, E-mail: nellis@physics.harvard.ed [Department of Physics, Harvard University, Cambridge MA 02138 (United States)

    2010-03-01

    Based on his 50-year career in static high-pressure research, P. W. Bridgman (PWB) is the father of modern high-pressure physics. What is not generally recognized is that Bridgman was also intimately connected with establishing shock compression as a scientific tool and he predicted major events in shock research that occurred up to 40 years after his death. In 1956 the first phase transition under shock compression was reported in Fe at 13 GPa (130 kbar). PWB said a phase transition could not occur in a {approx}microsec, thus setting off a controversy. The scientific legitimacy of shock compression resulted 5 years later when static high-pressure researchers confirmed with x-ray diffraction the existence of epsilon-Fe. Once PWB accepted the fact that shock waves generated with chemical explosives were a valid scientific tool, he immediately realized that substantially higher pressures would be achieved with nuclear explosives. He included his ideas for achieving higher pressures in articles published a few years after his death. L. V. Altshuler eventually read Bridgman's articles and pursued the idea of using nuclear explosives to generate super high pressures, which subsequently morphed today into giant lasers. PWB also anticipated combining static and shock methods, which today is done with pre-compression of a soft sample in a diamond anvil cell followed by laser-driven shock compression. One variation of that method is the reverberating-shock technique, in which the first shock pre-compresses a soft sample and subsequent reverberations isentropically compress the first-shocked state.

  1. Crystalline perfection and mechanical investigations on vertical Bridgman grown Bismuth telluride (Bi_2Te_3) single crystals for thermoelectric applications

    International Nuclear Information System (INIS)

    Krishna, Anuj; Vijayan, N.; Singh, Budhendra; Thukral, Kanika; Maurya, K.K.

    2016-01-01

    High efficiency thermoelectric materials plays a vital role in power generation and refrigeration applications. Bismuth telluride (Bi_2Te_3) is one among them. In the present work single crystal of bismuth telluride was grown using vertical Bridgman technique. The phase of grown crystals was analysed using a powder X-ray diffractometer. Quality of the grown crystal was assessed by using high resolution X-ray diffractometer and observed that it is fairly good. Further mechanical investigations on grown crystal was carried out using nano-indentation technique and various mechanical properties like hardness, stiffness and Young’s modulus were evaluated. Observed results clearly indicate its suitability for thermoelectric applications.

  2. Gap energy studied by optical transmittance in lead iodide monocrystals grown by Bridgman's Method

    Directory of Open Access Journals (Sweden)

    Veissid N.

    1999-01-01

    Full Text Available The bandgap energy as a function of temperature has been determined for lead iodide. The monocrystal was obtained in a vacuum sealed quartz ampoule inside a vertical furnace by Bridgman's method. The optical transmittance measurement enables to evaluate the values of Eg. By a fitting procedure of Eg as a function of temperature is possible to extract the parameters that govern its behavior. The variation of Eg with temperature was determined as: Eg(T = Eg(0 - aT2/(a + T, with: Eg(0 = (2.435 ± 0.008 eV, a = (8.7 ± 1.3 x 10-4 eV/K and a = (192 ± 90 K. The bandgap energy of lead iodide at room temperature was found to be 2.277 ± 0.007 eV.

  3. Shape Evolution of Detached Bridgman Crystals Grown in Microgravity

    Science.gov (United States)

    Volz, M. P.; Mazuruk, K.

    2015-01-01

    A theory describing the shape evolution of detached Bridgman crystals in microgravity has been developed. A starting crystal of initial radius r0 will evolve to one of the following states: Stable detached gap; Attachment to the crucible wall; Meniscus collapse. Only crystals where alpha plus omega is great than 180 degrees will achieve stable detached growth in microgravity. Results of the crystal shape evolution theory are consistent with predictions of the dynamic stability of crystallization (Tatarchenko, Shaped Crystal Growth, Kluwer, 1993). Tests of transient crystal evolution are planned for ICESAGE, a series of Ge and GeSi crystal growth experiments planned to be conducted on the International Space Station (ISS).

  4. Effect of sodium diffused into Bridgman CuInSe{sub 2+x}

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sunyoung, E-mail: sunyoung.park@mail.mcgill.ca; Champness, Clifford H.; Shih, Ishiang

    2016-10-15

    Highlights: For elemental Na diffused into Bridgman CuInSe2 samples: • Diffusion is deep and relatively fast, with a coefficient of 10{sup −10} to 10{sup −8} cm{sup 2}/s at 250 °C. • Creates clear n/p homojunctions in the chalcopyrite. • Creates, after subsequent air annealing, an XPS Se 3d peak at 59 eV for Na{sub 2}SeO{sub 3}. • Increases the XPS-determined [Se]/[Cu] concentration ratio at the sample surface. - Abstract: The study describes diffusion of elemental sodium into p-type samples of Bridgman-grown CuInSe{sub 2+x}, causing a change from p- to n-type behavior at the surface and deep into the material. This resulted in the creation of Na 1s and Se 3d XPS peaks at binding energies of 1071 and 54.5 eV respectively, where the latter has been attributed to CuInSe{sub 2} itself. Subsequent annealing of the samples in air gave rise to a second Se 3d peak at 59 eV, attributed to Na{sub 2}SeO{sub 3} by oxidation of Na{sub 2}Se. However, SeO{sub 2} also gives a peak at about the same binding energy. The presence of the diffused-in Na up to about 10% at the surface appears to promote the creation of a high ratio [Se]/[Cu] compound at the expense of the chalcopyrite at the sample surface. The diffused-in samples showed n/p homojunctions at depths of tens of microns for stoichiometric CuInSe{sub 2} and at smaller depths for CuInSe{sub 2.2}, with excess Se content. Estimates of the diffusion coefficient for Na into the Bridgman samples at 250 °C were in the range of 10{sup −10}–10{sup −8} cm{sup 2}/s.

  5. Technique for determining training staff size

    International Nuclear Information System (INIS)

    Frye, S.R.

    1985-01-01

    Determining an adequate training staff size is a vital function of a training manager. Today's training requirements and standards have dictated a more stringent work load than ever before. A trainer's role is more than just providing classroom lectures. In most organizations the instructor must develop programs, lesson plans, exercise guides, objectives, test questions, etc. The tasks of a training organization are never ending and the appropriate resources must be determined and allotted to do the total job. A simple method exists for determining an adequate staff. Although not perfect, this method will provide a realistic approach for determining the needed training staff size. This method considers three major factors: instructional man-hours; non-instructional man-hours; and instructor availability. By determining and adding instructional man-hours and non-instructional man-hours a total man-hour distribution can be obtained. By dividing this by instructor availability a staff size can be determined

  6. Radioimmunodiffusion technique for determining diphtheria antitoxin

    International Nuclear Information System (INIS)

    Maniar, A.C.

    1977-01-01

    A radioimmunodiffusion technique for detecting low levels of diphtheria antitoxin was developed. Diphtheria toxoid was labelled with 125 I to facilitate detection of lines of precipitation by the use of X-ray film, the lower limit of detection being 0.001 unit per millilitre of diphtheria antitoxin. (author)

  7. Method of insulin determination by radioimmunoassay technique

    Energy Technology Data Exchange (ETDEWEB)

    Kokot, F; Kuska, J [Slaska Akademia Medyczna, Katowice (Poland)

    1973-01-01

    Technical details of a radioimmunological method of insulin determination in blood serum have been presented. Clinical value of the method was checked in 31 healthy subjects following oral or intravenous glucose administration, or after pancreatic islet stimulation using tolbutamide.

  8. Techniques for determining physical zones of influence

    Science.gov (United States)

    Hamann, Hendrik F; Lopez-Marrero, Vanessa

    2013-11-26

    Techniques for analyzing flow of a quantity in a given domain are provided. In one aspect, a method for modeling regions in a domain affected by a flow of a quantity is provided which includes the following steps. A physical representation of the domain is provided. A grid that contains a plurality of grid-points in the domain is created. Sources are identified in the domain. Given a vector field that defines a direction of flow of the quantity within the domain, a boundary value problem is defined for each of one or more of the sources identified in the domain. Each of the boundary value problems is solved numerically to obtain a solution for the boundary value problems at each of the grid-points. The boundary problem solutions are post-processed to model the regions affected by the flow of the quantity on the physical representation of the domain.

  9. Determination of Ag in technique process research

    International Nuclear Information System (INIS)

    Su Tao; Zhang Lihua; Fan Dejun; Liu Huanliang; Wu Jizong

    2008-01-01

    Based on the chromogenic reaction of Ag with p-dimethylamino benzyl rhodanine, a new spectrophotometric method for determination of Ag in the presence of PVA-124 and Triton X-100 as surfactant is established. The factors such as acidity, reaction time and the concentration of surfactant were studied. The results show that the appropriate conditions are as the following. The concentrations of p-dimethylamino benzyl rhodanine, PVA and Triton X-100 are 0.1 g·L -1 , 10 g·L -1 and 0.16% respectively. Acidity is 1.0 mol·L -1 . Reaction time is 20 minutes. Absorption wavelength is 470 nm. The influence of several coexisting ions, especially Pu (Ⅳ) on analyzing Ag is also studied. The results indicate that when the concentration of Ag is less than five times of the concentration of Pu. PMBP is used to extract Pu (Ⅳ). The optimum extraction conditions are as follows. The concentration of PMBP is 0.1 mol·L-1. Acidity is 2.0 mol·L-1. The ratio of organic and water phase is 1:1. Extraction time is 3 minutes. Conformity to Berr's law was obtained with the scope of 0.1-1.0 μg·mL -1 . The determination limit of Ag is 0.1 μg·mL -1 . The relative standard deviation for this method is 2.6% (n=3). The recovery is 104-114%. (authors)

  10. The application of different techniques to determine activated sludge ...

    African Journals Online (AJOL)

    The application of different techniques to determine activated sludge kinetic parameters in a food industry wastewater. ... method) and a respirometric technique based on oxygen consumption measurements, were used to compare microbial parameters using a wastewater model system of a potato processing plant.

  11. A simplified technique for shakedown limit load determination

    International Nuclear Information System (INIS)

    Abdalla, Hany F.; Megahed, Mohammad M.; Younan, Maher Y.A.

    2007-01-01

    In this paper, a simplified technique is presented to determine the shakedown limit load of a structure using the finite element method. The simplified technique determines the shakedown limit load without performing lengthy time consuming full elastic-plastic cyclic loading simulations or conventional iterative elastic techniques. Instead, the shakedown limit load is determined by performing two analyses namely: an elastic analysis and an elastic-plastic analysis. By extracting the results of the two analyses, the shakedown limit load is determined through the calculation of the residual stresses developed within the structure. The simplified technique is applied and verified using two bench mark shakedown problems namely: the two-bar structure subjected to constant axial force and cyclic thermal loading, and the Bree cylinder subjected to constant internal pressure and cyclic high temperature variation across its wall. The results of the simplified technique showed very good correlation with the, analytically determined, Bree diagrams of both structures. In order to gain confidence in the simplified technique, the shakedown limit loads output by the simplified technique are used to perform full elastic-plastic cyclic loading simulations to check for shakedown behavior of both structures

  12. Diffusion length variation in photovoltaic cells with Bridgman-grown CuInSe2 substrates

    International Nuclear Information System (INIS)

    Champness, C.H.

    2007-01-01

    In a group of CuInSe 2 -CdS-ZnO photovoltaic cells, where the absorber was a layer cut from Bridgman-grown p-type CuInSe 2 ingots, electron diffusion lengths at room temperature (L n ) were estimated by the photocurrent-capacitance method. Dark capacitance measurements were also made on the same cells against reverse bias and from Mott-Schottky plots, slope concentrations p MS were determined at a reverse bias of 1.5 V. In a plot of L n against p MS , it was found that, despite much scatter in the experimental points, there was an apparent trend of L n decreasing by about an order of magnitude with increase of p MS from 10 16 to 10 17 cm -3 . Detailed proposals were then made to explain this trend. These were reduction of lifetime via Shockley-Read trapping with mobility decrease by impurity scattering, shunt resistance lowering by light and optical penetration depth reduction at shorter illumination wavelengths

  13. Performance of thallium bromide semiconductor detectors produced by repeated Bridgman method

    International Nuclear Information System (INIS)

    Santos, Robinson Alves dos; Costa, Fabio Eduardo da; Martins, Joao Francisco Trencher; Hamada, Margarida M.

    2009-01-01

    TlBr crystals have been grown by the Repeated Bridgman method from commercial TlBr materials and characterized to be used as radiation detectors. We have shown that the Repeated Bridgman is effective to reduce the concentration of impurities in TlBr. It was observed that detectors fabricated from higher purity crystal exhibit significant improvement in performance compared to those produced from low purity crystals. However, problems still exist in TlBr detectors, due to the low charge carrier collection efficiency, which is probably caused by additional impurities or defects incorporated during crystal growth and detector fabrication processes. (author)

  14. Development of XAFS Into a Structure Determination Technique

    Science.gov (United States)

    Stern, E. A.

    After the detection of diffraction of x-rays by M. Laue in 1912, the technique was soon applied to structure determination by Bragg within a year. On the other hand, although the edge steps in X-Ray absorption were discovered even earlier by Barkla and both the near edge (XANES) and extended X-Ray fine structure (EXAFS) past the edge were detected by 1929, it still took over 40 years to realize the structure information contained in this X-Ray absorption fine structure (XAFS). To understand this delay a brief historical review of the development of the scientific ideas that transformed XAFS into the premiere technique for local structure determination is given. The development includes both advances in theoretical understanding and calculational capabilities, and in experimental facilities, especially synchrotron radiation sources. The present state of the XAFS technique and its capabilities are summarized.

  15. Delphi Fuzzy Elicitation Technique in the Determination of Third ...

    African Journals Online (AJOL)

    The Delphi technique via the expert elicitation method becomes extremely handy particularly in view of limited availability of data in determining failure probabilities of onshore transmission pipelines in the Niger Delta region of Nigeria occasioned by third party activity. Using, ten (10) experts opinion elucidated individually ...

  16. Comparison of age determination techniques for known-age Cape ...

    African Journals Online (AJOL)

    Known-age teeth were used to validate age determination techniques for the Cape fur seal (Arctocephalus ... The reliability with which age can be estimated for the Cape fur seal has also been improved. ... The acid solution, with a volume at least 10 times that of ... old female [0 show (he absence of GLGs in the cemenlUnl.

  17. Improvement of Analytical Technique for Determination of Gold in ...

    African Journals Online (AJOL)

    This article elucidates the improvement of analytical technique for determination of gold in geological matrix. Samples suspected to have gold in them were subjected to neutron flux from the Nigeria Research Reactor (NRR-1), a Miniature Neutron Source Reactor (MNSR). Two geological samples – one sample was ...

  18. Uranium determination using atomic spectrometric techniques: An overview

    International Nuclear Information System (INIS)

    Santos, Juracir S.; Teixeira, Leonardo S.G.; Santos, Walter N.L. dos; Lemos, Valfredo A.; Godoy, Jose M.; Ferreira, Sergio L.C.

    2010-01-01

    This review focuses on the determination of uranium using spectroanalytical techniques that are aimed at total determination such as flame atomic absorption spectrometry (FAAS), electrothermal atomic absorption spectrometry (ETAAS), inductively coupled plasma optical emission spectrometry (ICP-OES); and inductively coupled plasma mass spectrometry (ICP-MS) that also enables the determination of uranium isotopes. The advantages and shortcomings related to interferences, precision, accuracy, sample type and equipment employed in the analysis are taken into account, as well as the complexity and costs (i.e., acquisition, operation and maintenance) associated with each of the techniques. Strategies to improve their performance that employ separation and/or preconcentration steps are considered, with an emphasis given to solid-phase extraction because of its advantages compared to other preconcentration procedures.

  19. Technique for determining cesium-137 in milk excluding ashing

    International Nuclear Information System (INIS)

    Antonova, V.A.; Prokof'ev, O.N.

    1984-01-01

    For the purpose of simplification of the method of milk sample preparation for the radiochemical analysis for 137 Cs in laboratory sanitary and higienic investigations rapid analysis technique excluding sample ashing is developed. The technique comprises sample mixing with silica gel during an hour, 137 Cs desorption from silica gel into the 1N solution of hydrochloric acid, radiochemical analysis of hydrochloric solution for determining 137 Cs. The comparison of the results obtained by the above method and that with ashing provides perfect agreement. For taking into account the incompleteness of 137 Cs adsorption by silica gel a correction factor is applied in calculation formulae

  20. Determination of palladium in biological samples applying nuclear analytical techniques

    International Nuclear Information System (INIS)

    Cavalcante, Cassio Q.; Sato, Ivone M.; Salvador, Vera L. R.; Saiki, Mitiko

    2008-01-01

    This study presents Pd determinations in bovine tissue samples containing palladium prepared in the laboratory, and CCQM-P63 automotive catalyst materials of the Proficiency Test, using instrumental thermal and epithermal neutron activation analysis and energy dispersive X-ray fluorescence techniques. Solvent extraction and solid phase extraction procedures were also applied to separate Pd from interfering elements before the irradiation in the nuclear reactor. The results obtained by different techniques were compared against each other to examine sensitivity, precision and accuracy. (author)

  1. Further comments on segregation during Bridgman growth of Cd(x)Hg(1-x)Te

    Science.gov (United States)

    Lehoczky, S. L.; Szofran, F. R.

    1984-01-01

    The authors comment on recent papers published by Capper et al. (1983) and Jones et al. (1983) which report and discuss the variation of composition with axial position in Bridgman-grown Cd(x)Hg(1-x)Te alloys. The validity of a diffusion-controlled model for non-mixing growth conditions is particularly noted.

  2. Determining flexor-tendon repair techniques via soft computing

    Science.gov (United States)

    Johnson, M.; Firoozbakhsh, K.; Moniem, M.; Jamshidi, M.

    2001-01-01

    An SC-based multi-objective decision-making method for determining the optimal flexor-tendon repair technique from experimental and clinical survey data, and with variable circumstances, was presented. Results were compared with those from the Taguchi method. Using the Taguchi method results in the need to perform ad-hoc decisions when the outcomes for individual objectives are contradictory to a particular preference or circumstance, whereas the SC-based multi-objective technique provides a rigorous straightforward computational process in which changing preferences and importance of differing objectives are easily accommodated. Also, adding more objectives is straightforward and easily accomplished. The use of fuzzy-set representations of information categories provides insight into their performance throughout the range of their universe of discourse. The ability of the technique to provide a "best" medical decision given a particular physician, hospital, patient, situation, and other criteria was also demonstrated.

  3. Biomechanical determinants of elite rowing technique and performance.

    Science.gov (United States)

    Buckeridge, E M; Bull, A M J; McGregor, A H

    2015-04-01

    In rowing, the parameters of injury, performance, and technique are all interrelated and in dynamic equilibrium. Whilst rowing requires extreme physical strength and endurance, a high level of skill and technique is essential to enable an effective transfer of power through the rowing sequence. This study aimed to determine discrete aspects of rowing technique, which strongly influence foot force production and asymmetries at the foot-stretchers, as these are biomechanical parameters often associated with performance and injury risk. Twenty elite female rowers performed an incremental rowing test on an instrumented rowing ergometer, which measured force at the handle and foot-stretchers, while three-dimensional kinematic recordings of the ankle, knee, hip, and lumbar-pelvic joints were made. Multiple regression analyses identified hip kinematics as a key predictor of foot force output (R(2)  = 0.48), whereas knee and lumbar-pelvic kinematics were the main determinants in optimizing the horizontal foot force component (R(2)  = .41). Bilateral asymmetries of the foot-stretchers were also seen to significantly influence lumbar-pelvic kinematics (R(2)  = 0.43) and pelvic twisting (R(2)  = 0.32) during the rowing stroke. These results provide biomechanical evidence toward aspects of technique that can be modified to optimize force output and performance, which can be of direct benefit to coaches and athletes. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Determination of dynamic fracture toughness using a new experimental technique

    Directory of Open Access Journals (Sweden)

    Cady Carl M.

    2015-01-01

    Full Text Available In other studies dynamic fracture toughness has been measured using Charpy impact and modified Hopkinson Bar techniques. In this paper results will be shown for the measurement of fracture toughness using a new test geometry. The crack propagation velocities range from ∼0.15 mm/s to 2.5 m/s. Digital image correlation (DIC will be the technique used to measure both the strain and the crack growth rates. The boundary of the crack is determined using the correlation coefficient generated during image analysis and with interframe timing the crack growth rate and crack opening can be determined. A comparison of static and dynamic loading experiments will be made for brittle polymeric materials. The analysis technique presented by Sammis et al. [1] is a semi-empirical solution, however, additional Linear Elastic Fracture Mechanics analysis of the strain fields generated as part of the DIC analysis allow for the more commonly used method resembling the crack tip opening displacement (CTOD experiment. It should be noted that this technique was developed because limited amounts of material were available and crack growth rates were to fast for a standard CTOD method.

  5. Determination of dynamic fracture toughness using a new experimental technique

    Science.gov (United States)

    Cady, Carl M.; Liu, Cheng; Lovato, Manuel L.

    2015-09-01

    In other studies dynamic fracture toughness has been measured using Charpy impact and modified Hopkinson Bar techniques. In this paper results will be shown for the measurement of fracture toughness using a new test geometry. The crack propagation velocities range from ˜0.15 mm/s to 2.5 m/s. Digital image correlation (DIC) will be the technique used to measure both the strain and the crack growth rates. The boundary of the crack is determined using the correlation coefficient generated during image analysis and with interframe timing the crack growth rate and crack opening can be determined. A comparison of static and dynamic loading experiments will be made for brittle polymeric materials. The analysis technique presented by Sammis et al. [1] is a semi-empirical solution, however, additional Linear Elastic Fracture Mechanics analysis of the strain fields generated as part of the DIC analysis allow for the more commonly used method resembling the crack tip opening displacement (CTOD) experiment. It should be noted that this technique was developed because limited amounts of material were available and crack growth rates were to fast for a standard CTOD method.

  6. Tracer techniques for determination of groundwater flow parameters

    International Nuclear Information System (INIS)

    Drost, W.; Klotz, D.

    1988-05-01

    The most common one-borehole and multiple borehole methods using tracers for the direct determination of the groundwater flow parameters (velocity of flow, flow direction) and for the indirect determination of characteristic quantities of the aquifer (effective porosity, dispersivity, transmissivity) are presented methodically and their value is documented by practical examples. Especially, the properties of and measuring technique with suitable tracers are considered (e.g. T, Na-24, Cr-51, Co-58, Co-60, Br-82, Tc-99, I-125, I-131, Au-198). (orig./HP) [de

  7. ELISA techniques for the determination of methanogenic bacteria

    Energy Technology Data Exchange (ETDEWEB)

    Bryniok, D; Troesch, W [Fraunhofer-Institut fuer Grenzflaechen- und Bioverfahrenstechnik (IGB), Stuttgart (Germany, F.R.)

    1989-12-01

    Easy-to-handle enzyme-linked immunosorbent assay (ELISA) techniques have been developed suitable for quantitative species-specific determination of very low numbers of methanogens in complex bacterial populations. The amount and the distribution of different species of methanogens in anaerobic digestors is a reflection of the functional status of the degradation process; this can be recognized with these tests and hence may be used for process control. (orig.).

  8. Sulfated oligosaccharide structures, as determined by NMR techniques

    International Nuclear Information System (INIS)

    Noseda, M.D.; Duarte, M.E.R.; Tischer, C.A.; Gorin, P.A.J.; Cerezo, A.S.

    1997-01-01

    Carrageenans are sulfated polysaccharides, produced by red seaweeds (Rhodophyta), that have important biological and physico-chemical properties. Using partial autohydrolysis, we obtained sulfated oligosaccharides from a λ-carrageenan (Noseda and Cerezo, 1993). These oligosaccharides are valuable not only for the study of the structures of the parent carrageenans but also for their possible biological activities. In this work we determined the chemical structure of one of the sulfated oligosaccharides using 1D and 2D NMR techniques. (author)

  9. Determination of uranium in ground water using different analytical techniques

    International Nuclear Information System (INIS)

    Sahu, S.K.; Maity, Sukanta; Bhangare, R.C.; Pandit, G.G.; Sharma, D.N.

    2014-10-01

    The concern over presence of natural radionuclides like uranium in drinking water is growing recently. The contamination of aquifers with radionuclides depends on number of factors. The geology of an area is the most important factor along with anthropogenic activities like mining, coal ash disposal from thermal power plants, use of phosphate fertilizers etc. Whatever may be the source, the presence of uranium in drinking waters is a matter of great concern for public health. Studies show that uranium is a chemo-toxic and nephrotoxic heavy metal. This chemotoxicity affects the kidneys and bones in particular. Seeing the potential health hazards from natural radionuclides in drinking water, many countries worldwide have adopted the guideline activity concentration for drinking water quality recommended by the WHO (2011). For uranium, WHO has set a limit of 30μgL-1 in drinking water. The geological distribution of uranium and its migration in environment is of interest because the element is having environmental and exposure concerns. It is of great interest to use an analytical technique for uranium analysis in water which is highly sensitive especially at trace levels, specific and precise in presence of other naturally occurring major and trace metals and needs small amount of sample. Various analytical methods based on the use of different techniques have been developed in the past for the determination of uranium in the geological samples. The determination of uranium requires high selectivity due to its strong association with other elements. Several trace level wet chemistry analytical techniques have been reported for uranium determination, but most of these involve tedious and pain staking procedures, high detection limits, interferences etc. Each analytical technique has its own merits and demerits. Comparative assessment by different techniques can provide better quality control and assurance. In present study, uranium was analysed in ground water samples

  10. Recent Microextraction Techniques for Determination and Chemical Speciation of Selenium

    Directory of Open Access Journals (Sweden)

    Ibrahim Ahmed S. A.

    2017-05-01

    Full Text Available Research designed to improve extraction has led to the development of microextraction techniques (ME, which involve simple, low cost, and effective preconcentrationof analytes in various matrices. This review is concerned with the principles and theoretical background of ME, as well as the development of applications for selenium analysis during the period from 2008 to 2016. Among all ME, dispersive liquid-liquid microextraction was found to be most favorable for selenium. On the other hand, atomic absorption spectrometry was the most frequently used instrumentation. Selenium ME have rarely been coupled to spectrophotometry and X-ray spectrophotometry methods, and there is no published application of ME with electrochemical techniques. We strongly support the idea of using a double preconcentration process, which consists of microextraction prior to preconcentration, followed by selenium determination using cathodic stripping voltammetry (ME-CSV. More attention should focus on the development of accurate, precise, and green methods for selenium analysis.

  11. Determination of contraband using fast neutron resonance technique

    Energy Technology Data Exchange (ETDEWEB)

    Bae, J.; Whang, J. [Kyunghee Univ., Dept. of Nuclear Engineering, Yongin-shi, Kyongki-do (Korea, Republic of)

    2004-07-01

    'Full-text:' Resonance technique with monoenergetic fast neutron beam is able to map features in bulk samples in a way that is sensitive to their elemental composition. It has a number of potential applications, for example, in mining and in the detection of contraband materials such as illicit drugs and explosives. By moving around the neutron detector experiences neutrons in the form of narrow line beam with different energies as the angle to the neutron source changes. Projection data was obtained using the Monte Carlo code MCNP4C. Therefore the fast neutrons scattered from an unknown object are used to determine the elemental content of the object and hence lead to its identification. Scattered features simulated for various test materials are analyzed using the HEPRO program system (PTB, Braunschweig) to determine the atom weight fractions for H. C. N, O and other elements in the materials. Atom weight fractions determined from scattering features are insensitive to neutron interactions in interfering materials surrounding the object. The simulations demonstrate that the fast neutron resonance technique (FNRT) provides reliable elemental characterization of bulk materials and has the necessary sensitivity to distinguish between drugs, explosives and other materials. (author)

  12. Determination of contraband using fast neutron resonance technique

    International Nuclear Information System (INIS)

    Bae, J.; Whang, J.

    2004-01-01

    'Full-text:' Resonance technique with monoenergetic fast neutron beam is able to map features in bulk samples in a way that is sensitive to their elemental composition. It has a number of potential applications, for example, in mining and in the detection of contraband materials such as illicit drugs and explosives. By moving around the neutron detector experiences neutrons in the form of narrow line beam with different energies as the angle to the neutron source changes. Projection data was obtained using the Monte Carlo code MCNP4C. Therefore the fast neutrons scattered from an unknown object are used to determine the elemental content of the object and hence lead to its identification. Scattered features simulated for various test materials are analyzed using the HEPRO program system (PTB, Braunschweig) to determine the atom weight fractions for H. C. N, O and other elements in the materials. Atom weight fractions determined from scattering features are insensitive to neutron interactions in interfering materials surrounding the object. The simulations demonstrate that the fast neutron resonance technique (FNRT) provides reliable elemental characterization of bulk materials and has the necessary sensitivity to distinguish between drugs, explosives and other materials. (author)

  13. Sulfated oligosaccharide structures, as determined by NMR techniques

    Energy Technology Data Exchange (ETDEWEB)

    Noseda, M.D.; Duarte, M.E.R.; Tischer, C.A.; Gorin, P.A.J. [Parana Univ., Curitiba, PR (Brazil). Dept. De Bioquimica; Cerezo, A.S. [Buenos Aires Univ. Nacional (Argentina). Dept. de Quimica Organica

    1997-12-31

    Carrageenans are sulfated polysaccharides, produced by red seaweeds (Rhodophyta), that have important biological and physico-chemical properties. Using partial autohydrolysis, we obtained sulfated oligosaccharides from a {lambda}-carrageenan (Noseda and Cerezo, 1993). These oligosaccharides are valuable not only for the study of the structures of the parent carrageenans but also for their possible biological activities. In this work we determined the chemical structure of one of the sulfated oligosaccharides using 1D and 2D NMR techniques. (author) 4 refs., 8 figs., 1 tabs.

  14. Proton-activation technique for the determination of antimony

    International Nuclear Information System (INIS)

    Krivan, V.; Barth, P.

    1979-01-01

    Photon-activation analysis has been applied to the determination of antimony. Thick-target yields and analytical sensitivities are given for the indicator-radionuclides sup(119m)Te, sup(119g)Te, sup(121m)Te, sup(121g)Te, sup(123m)Te, sup(120m)Sb and sup(122g)Sb for proton energies between 9 and 25 MeV. In irradiations with a 5-μA beam for 5 hr, followed by a specific separation of the indicator-radionuclides, limits of detection at the ppm level can be achieved. Data are given for the most significant interfering reactions. Antimony was determined instrumentally in bismuth of very pure grade and the results are compared with those obtained from two independent techniques. (author)

  15. Technique for Determining Lock Coefficient of Differential "Quif"

    Directory of Open Access Journals (Sweden)

    A. B. Fominyh

    2015-01-01

    Full Text Available Increasing the traction qualities of cars on the black ice and snow-covered roads is a relevant task. There are two ways to solve this task, i.e. optimize distribution of the power stream between the driving wheels of the car; introduce a differential (differentials of the increased friction in transmission.Now, an installation of the increased friction differential in transmission is the most widespread measure to increase traction properties of cars. The differential of design "Quif" is one of such differentials. To estimate the efficiency degree of using such a differential is possible either experimentally or theoretically. In case of theoretically determined usefulness of this differential design, as an estimate indicator of the differential installation in transmission a coefficient of lock is accepted.The article considers an algorithm and a technique to calculate a lock coefficient of the differential design "Quif" allowing us to define numeric values of the lock coefficient of such differential at designing stage. It also considers how the lock coefficient depends on the gearing angle and tilt angle of the gear wheel teeth of differential. The given estimating algorithm of designated parameter of differential has more logical and compact structure with regard to the known ones. The lock coefficient values calculated by the offered technique differ from the experimental data by no more than 12%. Taking into account abovementioned, the presented technique for calculating lock coefficient of differential "Quif" is advisable for practical application.

  16. Fast sorting measurement technique to determine decontamination priority

    International Nuclear Information System (INIS)

    Distenfeld, C.H.; Brosey, B.; Igarashi, H.

    1986-01-01

    The method used to select decontamination priorities for the Three Mile Island Unit 2 (TMI-2) reactor building (RB) is systematic, but costs in personnel exposure and time must be borne. One way of minimizing exposure is to define and treat the one or two surface sources that are important contributors to the collective dose of the recovery personnel. Surface characteristics can then be determined and decontamination techniques developed to match the removal requirements. At TMI-2, a fast sorting technique was developed and used to prioritize surfaces for exposure reduction. A second quick sort can then be used to determine the next generation of surface characterization, decontamination method selection, and performance. The quick-sort method that was developed is based on the Eberline HP 220A probes directional survey system. The angular response of the HP 220A probes approaches 2 pi steradians and allows toward-away type measurements. Sources distributed over 4 pi steradians are hard to define with this system. Angular differentiation was improved to about pi/2 steradians by redesigning the probe shield. The change allows unambiguous six-direction measurements, such as up, down, front, rear, right, and left with practically no angular overlap or exclusion. A simple, light-weight stand was used to establish an angular reference for the rectangular packaged probe. The six surface planes of the rectangle work with the angular reference to establish the six viewing angles

  17. A Monte Carlo simulation technique to determine the optimal portfolio

    Directory of Open Access Journals (Sweden)

    Hassan Ghodrati

    2014-03-01

    Full Text Available During the past few years, there have been several studies for portfolio management. One of the primary concerns on any stock market is to detect the risk associated with various assets. One of the recognized methods in order to measure, to forecast, and to manage the existing risk is associated with Value at Risk (VaR, which draws much attention by financial institutions in recent years. VaR is a method for recognizing and evaluating of risk, which uses the standard statistical techniques and the method has been used in other fields, increasingly. The present study has measured the value at risk of 26 companies from chemical industry in Tehran Stock Exchange over the period 2009-2011 using the simulation technique of Monte Carlo with 95% confidence level. The used variability in the present study has been the daily return resulted from the stock daily price change. Moreover, the weight of optimal investment has been determined using a hybrid model called Markowitz and Winker model in each determined stocks. The results showed that the maximum loss would not exceed from 1259432 Rials at 95% confidence level in future day.

  18. Numerical Study of Thermal Stresses for the Semiconductor CdZnTe in Vertical Bridgman

    OpenAIRE

    Jamai , Hanen; El Ganaoui , M.; Sammouda , Habib; Pateyron , Bernard

    2015-01-01

    International audience; The aim of this work is to present a numerical simulation of thermal stress in directional solidification of CdZnTe in vertical Bridgman apparatus. Especial attention will be attributed to show the importance of cooling temperature and time's growth affecting the thermal stress. Furthermore, we will focus on investigating the thermal stress' components and their distribution in crystal, which gives a detailed about the stress distribution and consequently on the distri...

  19. Nondestructive NMR technique for moisture determination in radioactive materials

    International Nuclear Information System (INIS)

    Aumeier, S.; Gerald, R.E. II; Growney, E.; Nunez, L.; Kaminski, M.

    1998-01-01

    This progress report focuses on experimental and computational studies used to evaluate nuclear magnetic resonance (NMR) spectroscopy and magnetic resonance imaging (MRI) for detecting, quantifying, and monitoring hydrogen and other magnetically active nuclei ( 3 H, 3 He, 239 Pu, 241 Pu) in Spent nuclear fuels and packaging materials. The detection of moisture by using a toroid cavity NMR imager has been demonstrated in SiO 2 and UO 2 systems. The total moisture was quantified by means of 1 H NMR detection of H 2 O with a sensitivity of 100 ppm. In addition, an MRI technique that was used to determine the moisture distribution also enabled investigators to discriminate between bulk and stationary water sorbed on the particles. This imaging feature is unavailable in any other nondestructive assay (NDA) technique. Following the initial success of this program, the NMR detector volume was scaled up from the original design by a factor of 2000. The capacity of this detector exceeds the size specified by DOE-STD-3013-96

  20. Bridgman growth and characterization of bulk single crystals of Ga1-xInxSb for thermophotovoltaic applications

    International Nuclear Information System (INIS)

    Boyer, J.R.; Haines, W.T.

    1997-12-01

    Thermophotovoltaic generation of electricity is attracting renewed attention due to recent advances in low bandgap (0.5--0.7 eV) III-V semiconductors. The use of mixed pseudo-binary compounds allows for the tailoring of the lattice parameter and the bandgap of the material. Conventional deposition techniques (i.e., epitaxy) for producing such ternary or quaternary materials are typically slow and expensive. Production of bulk single crystals of ternary materials, for example Ga 1-x In x Sb, is expected to dramatically reduce such material costs. Bulk single crystals of Ga 1-x In x Sb have been prepared using a Bridgman technique in a two-zone furnace. These crystals are 19 mm in diameter by approximately 50 mm long and were produced using seeds of the same diameter. The effects of growth rate and starting materials on the composition and quality of these crystals will be discussed and compared with other attempts to produce single crystals of this material

  1. Determination of molecular parameters by electron collisions and laser techniques

    International Nuclear Information System (INIS)

    Colon, C.

    1989-01-01

    In this work a general procedure to study diatomic molecules in intermediate coupling scheme has been developed. This study allows to obtain expressions to calculate molecular line strengths and rotational transition intensities. These results are used in a numerical program to synthetize vibrational and rotational band spectra of any diatomic molecule. With this technique the experimental spectra of the first negative system of N 2 + and the fist positive system of N 2 are reproduced theoretically and it is possible to deduce its electronic transition moments values by comparison. Also the method has been applied to compare the synthetized bands with the experimental spectra of the B O u + -- x 1 Σ g + system of Au 2 and the A 2 Σ--- x 2 π system of OH. From these comparison band intensities and electronic moments can be deduced. The branching ratio method to measure the relative spectral response in the 1100-1560 A o =wavelength range of a vacuum uv monochromator has been used. Relative intensity of rotational lines with origine in a common upper vibrational-rotational level of Warner and Lyman systems of H 2 , have been measured. Also in this work, the deexcitation of the B 3 π + (0 + u ), v'=14 level of I 2 after pulsed laser excitation has been studied. The quenching cross sections by collisions with I 2 , H 2 , CO 2 and CH 4 have been determin-ed. (Author)

  2. Crystalline perfection and mechanical investigations on vertical Bridgman grown Bismuth telluride (Bi{sub 2}Te{sub 3}) single crystals for thermoelectric applications

    Energy Technology Data Exchange (ETDEWEB)

    Krishna, Anuj [Academy of Scientific and Innovative Research, CSIR- National Physical Laboratory, New Delhi 110012 (India); X-ray Analysis and Crystal Growth Section, CSIR-National Physical Laboratory, Dr. K.S. Krishnan Road, New Delhi 110012 (India); Vijayan, N., E-mail: nvijayan@nplindia.org [X-ray Analysis and Crystal Growth Section, CSIR-National Physical Laboratory, Dr. K.S. Krishnan Road, New Delhi 110012 (India); Singh, Budhendra [TEMA-NRD, Mechanical Engineering Department and Aveiro Institute of Nanotechnology (AIN), University of Aveiro, 3810-193 Aveiro (Portugal); Thukral, Kanika [Academy of Scientific and Innovative Research, CSIR- National Physical Laboratory, New Delhi 110012 (India); X-ray Analysis and Crystal Growth Section, CSIR-National Physical Laboratory, Dr. K.S. Krishnan Road, New Delhi 110012 (India); Maurya, K.K. [X-ray Analysis and Crystal Growth Section, CSIR-National Physical Laboratory, Dr. K.S. Krishnan Road, New Delhi 110012 (India)

    2016-03-07

    High efficiency thermoelectric materials plays a vital role in power generation and refrigeration applications. Bismuth telluride (Bi{sub 2}Te{sub 3}) is one among them. In the present work single crystal of bismuth telluride was grown using vertical Bridgman technique. The phase of grown crystals was analysed using a powder X-ray diffractometer. Quality of the grown crystal was assessed by using high resolution X-ray diffractometer and observed that it is fairly good. Further mechanical investigations on grown crystal was carried out using nano-indentation technique and various mechanical properties like hardness, stiffness and Young’s modulus were evaluated. Observed results clearly indicate its suitability for thermoelectric applications.

  3. Mechanical Properties of Nanostructured Materials Determined Through Molecular Modeling Techniques

    Science.gov (United States)

    Clancy, Thomas C.; Gates, Thomas S.

    2005-01-01

    The potential for gains in material properties over conventional materials has motivated an effort to develop novel nanostructured materials for aerospace applications. These novel materials typically consist of a polymer matrix reinforced with particles on the nanometer length scale. In this study, molecular modeling is used to construct fully atomistic models of a carbon nanotube embedded in an epoxy polymer matrix. Functionalization of the nanotube which consists of the introduction of direct chemical bonding between the polymer matrix and the nanotube, hence providing a load transfer mechanism, is systematically varied. The relative effectiveness of functionalization in a nanostructured material may depend on a variety of factors related to the details of the chemical bonding and the polymer structure at the nanotube-polymer interface. The objective of this modeling is to determine what influence the details of functionalization of the carbon nanotube with the polymer matrix has on the resulting mechanical properties. By considering a range of degree of functionalization, the structure-property relationships of these materials is examined and mechanical properties of these models are calculated using standard techniques.

  4. Evaluation of in vivo techniques for the determination of apparent ...

    African Journals Online (AJOL)

    The cannulation technique is the most attractive method for use with piglets in terms of the lower variation in digestibility values. Practical aspects such as ease of handling and sampling, surgical trauma and piglet stress, are also important and contribute to the selection of the cannula technique as the most appropriate.

  5. Experimental verification of agreement between thermal and real time visual melt-solid interface positions in vertical Bridgman grown germanium

    Science.gov (United States)

    Barber, P. G.; Fripp, A. L.; Debnam, W. J.; Woodell, G.; Berry, R. F.; Simchick, R. T.

    1996-03-01

    Measurements of the liquid-solid interface position during crystal growth were made by observing the discontinuity of the temperature gradient with movable thermocouples in a centerline, quartz capillary placed inside a sealed quartz ampoule of germanium in a vertical Bridgman furnace. Simultaneously, in situ, real time visual observations, using X-ray imaging technology, determined the position of the melt-solid interface. The radiographically detected interface position was several millimeters from the thermal interface position and the direction of displacement depended upon the direction of thermocouple insertion. Minimization of this spurious heat flow was achieved by using an unclad thermocouple that had each of its two wire leads entering the capillary from different ends of the furnace. Using this configuration the visual interface coincided with the thermal interface. Such observations show the utility of using in situ, real time visualization to record the melt-solid interface shape and position during crystal growth; and they suggest improvements in furnace and ampoule designs for use in high thermal gradients.

  6. Growth of Bi doped cadmium zinc telluride single crystals by Bridgman oscillation method and its structural, optical, and electrical analyses

    International Nuclear Information System (INIS)

    Carcelen, V.; Rodriguez-Fernandez, J.; Dieguez, E.; Hidalgo, P.

    2010-01-01

    The II-VI compound semiconductor cadmium zinc telluride (CZT) is very useful for room temperature radiation detection applications. In the present research, we have successfully grown Bi doped CZT single crystals with two different zinc concentrations (8 and 14 at. %) by the Bridgman oscillation method, in which one experiment has been carried out with a platinum (Pt) tube as the ampoule support. Pt also acts as a cold finger and reduces the growth velocity and enhances crystalline perfection. The grown single crystals have been studied with different analysis methods. The stoichiometry was confirmed by energy dispersive by x-ray and inductively coupled plasma mass spectroscopy analyses and it was found there is no incorporation of impurities in the grown crystal. The presence of Cd and Te vacancies was determined by cathodoluminescence studies. Electrical properties were assessed by I-V analysis and indicated higher resistive value (8.53x10 8 Ω cm) for the crystal grown with higher zinc concentration (with Cd excess) compare to the other (3.71x10 5 Ω cm).

  7. Determinants of Peritoneal Dialysis Technique Failure in Incident US Patients

    OpenAIRE

    Shen, Jenny I.; Mitani, Aya A.; Saxena, Anjali B.; Goldstein, Benjamin A.; Winkelmayer, Wolfgang C.

    2013-01-01

    ♦ Objectives: Switching from peritoneal dialysis (PD) to hemodialysis (HD) is undesirable, because of complications from temporary vascular access, disruption of daily routine, and higher costs. Little is known about the role that social factors play in technique failure.

  8. Influence of gravitational and vibrational convection on the heat- and mass transfer in the melt during crystal growing by Bridgman and floating zone methods

    Science.gov (United States)

    Fedorov, Oleg

    2016-07-01

    Space materials science is one of the priorities of different national and international space programs. The physical processes of heat and mass transfer in microgravity (including effect of g-jitter) is far from complete clarity, especially for important practical technology for producing crystals from the melt. The idea of the impact on crystallizing melt by low frequency vibration includes not only the possibility to suppress unwanted microaccelerations, but also to actively influence the structure of the crystallization front. This approach is one of the most effective ways to influence the quality of materials produced in flight conditions. The subject of this work is the effect of vibrations on the thermal and hydrodynamic processes during crystal growth using Bridgman and floating zone techniques, which have the greatest prospect of practical application in space. In the present approach we consider the gravitational convection, Marangoni convection, as well as the effect of vibration on the melt for some special cases. The results of simulation were compared with some experimental data obtained by the authors using a transparent model substance - succinonitrile (Bridgman method), and silicon (floating zone method). Substances used, process parameters and characteristics of the experimental units correspond the equipment developed for onboard research and serve as a basis for selecting optimum conditions vibration exposure as a factor affecting the solidification pattern. The direction of imposing vibrations coincides with the axis of the crystal, the frequency is presented by the harmonic law, and the force of gravity was varied by changing its absolute value. Mathematical model considered axisymmetric approximation of joint convective-conductive energy transfer in the system crystal - melt. Upon application of low-frequency oscillations of small amplitude along the axis of growing it was found the suppression of the secondary vortex flows near the

  9. Soil organic matter (SOM) dynamics determined by stable isotope techniques

    International Nuclear Information System (INIS)

    Gerzabek, M. H.

    1998-09-01

    Being aware of limitations and possible bias the 13 C natural abundance technique using the different 13 C enrichments in plants with differing photosynthetic pathways in a powerful tool to quantify turnover processes, both in long-term field studies and short-term laboratory experiments. Special care is needed in choosing reference plots and the proper number of replicate samples. The combination of 13 C and 14 C measurements has a high potential for a further improvement of isotope techniques in SOM studies. Natural abundance of 15 N is less powerful with respect to quantification of SOM processes than the isotope dilution technique. However its usefulness could be distinctly improved by introducing other stable isotopes into the studies.(author)

  10. Speckle techniques for determining stresses in moving objects

    Science.gov (United States)

    Murphree, E. A.; Wilson, T. F.; Ranson, W. F.; Swinson, W. F.

    1978-01-01

    Laser speckle interferometry is a relatively new experimental technique which shows promise of alleviating many difficult problems in experimental mechanics. The method utilizes simple high-resolution photographs of the surface which is illuminated by coherent light. The result is a real-time or permanently stored whole-field record of interference fringes which yields a map of displacements in the object. In this thesis, the time-average theory using the Fourier transform is developed to present the application of this technique to measurement of in-plane displacement induced by the vibration of an object.

  11. Determination of rock depth using artificial intelligence techniques

    Institute of Scientific and Technical Information of China (English)

    R. Viswanathan; Pijush Samui

    2016-01-01

    This article adopts three artificial intelligence techniques, Gaussian Process Regression (GPR), Least Square Support Vector Machine (LSSVM) and Extreme Learning Machine (ELM), for prediction of rock depth (d) at any point in Chennai. GPR, ELM and LSSVM have been used as regression techniques. Latitude and longitude are also adopted as inputs of the GPR, ELM and LSSVM models. The performance of the ELM, GPR and LSSVM models has been compared. The developed ELM, GPR and LSSVM models produce spatial variability of rock depth and offer robust models for the prediction of rock depth.

  12. Determination of water table using electrical sounding technique: A ...

    African Journals Online (AJOL)

    Models were generated for computer iterative technique and Borehole data were also collected using spontaneous potential logging method as well as driller's log in some selected sites within the study area so as to correlate surface measurement with borehole records. Analysis based on three depth related resistivity ...

  13. A non-invasive technique for age at death determination

    DEFF Research Database (Denmark)

    Lynnerup, N; Thomsen, I; Frohlich, B

    1990-01-01

    by identification of one of the five phases. An exact age determination of a single individual was not possible, but could be approximated to within 20 years. In forensic cases, however, where the removal of soft tissue is not always possible, this method can contribute to the final age determination when used...

  14. Plutonium determination in urine by techniques of mass spectrometry

    International Nuclear Information System (INIS)

    Hernandez M, H.; Yllera de Ll, A.

    2013-10-01

    The objective of this study was to develop an analytic method for quantification and plutonium reappraisal in plane tables of alpha spectrometry be means of the mass spectrometry technique of high resolution with plasma source inductively coupled and desolvator Aridus (Aridus-Hr-Icp-Ms) and mass spectrometry with accelerator (AMS). The obtained results were, the recovery percentage of Pu in the plane table was of ∼ 90% and activity minimum detectable obtained with Aridus-Hr-Icp-Ms and AMS was of ∼ 3 and ∼ 0.4 f g of 239 Pu, respectively. Conclusion, the results demonstrate the aptitude of the Aridus-Hr-Icp-Ms and AMS techniques in the Pu reappraisal in plane tables with bigger speed and precision, improving the values notably of the activity minimum detectable that can be obtained with the alpha spectrometry (∼ 50 f g of 239 Pu). (author)

  15. Evaluation of analytical techniques to determine matals in Sodium

    International Nuclear Information System (INIS)

    Biancifiori, M.A.; Zappa, G.; Amico, A.

    1985-01-01

    The influence of some instrumental parameters on the analysis of CA, Co, Cr, Cu, Fe, K, Mg, Mn, and Ni in Sodium solutions, by means of Flame Atomic Absorption Spectroscopy (FAAS), is evaluated. The best operating parameters are established and the possibility of application of this analytical technique to the detection of the metallic impurities in Sodium is evaluated, considering the concentration values of nuclear interest

  16. Bed load determination in Parana river by radioactive tracer technique

    International Nuclear Information System (INIS)

    Aoki, P.E.; Enokihara, C.T.; Rocca, H.C.C.; Bittencourt, A.V.L.

    1988-10-01

    Radioactive tracing technique with marked sand was employed to evaluate the bottom sediment drag of Parana river, near the future site for the ''Ilha Grande'' Dam in Guaira City (State of Parana). 198 Au radioisotope was employed and measurements had been performed for a period of fifteen days. A bed load rate of 952,3 t/day was obtained for a laminar layer of 0,33 m mean thickness and 1.65 m/day mean velocity. (author) [pt

  17. Electrical properties of bulk InP synthesized by modified horizontal Bridgman method

    International Nuclear Information System (INIS)

    Pak, K.; Matsui, M.; Fukuhara, H.; Nishinaga, T.; Nakamura, T.; Yasuda, Y.

    1986-01-01

    High purity polycrystalline InP has been required for preparation of starting materials in LEC pulling. Usually, these materials are synthesized by the horizontal Bridgman (HB) or gradient freeze (GF) method. The major problem for InP synthesis has been attributed to silicon contamination during the growth, as shown by several workers. In a previous paper, the authors proposed a model in which the silicon contamination would occur due to the transport of SiO and In/sub 2/O gas species from the In-P melt to the phosphorus region by the reaction of the melt with the quartz boat in the HB growth system and suggested that the Si concentration in the In-P melt would have an intimate correlation with the temperature in the phosphorus region. However, the effect of the temperature in the phosphorus region on the electrical properties has not been studied in details as of yet. In this note, a modified horizontal Bridgman (MHB) method was developed to reduce the residual donor impurities, and the reduction mechanism is discussed

  18. Non-invasive techniques for determining musculoskeleton body composition

    International Nuclear Information System (INIS)

    Cohn, S.H.

    1984-01-01

    In vivo neutron activation analysis, combined with gamma spectrometry, has ushered in a new era of clinical diagnosis and evaluation of therapies, as well as investigation into and modelling of body composition in both normal individuals and patients suffering from various diseases and dysfunctions. Body composition studies have provided baseline data on such vital constituents as nitrogen, potassium and calcium. The non-invasive measurement techniques are particularly suitable for study of the musculo-skeletal changes in body composition. Of particular relevance here is the measurement of calcium loss in astronauts during prolonged space flights

  19. Determination of zinc nutrient in the soil using isotope technique

    International Nuclear Information System (INIS)

    Suwadji, E.

    1975-01-01

    In this experiment the availability of soil Zn nutrient in various soil conditions (dry and submerged), and the efficiency of the application of Zn fertilizer in rice nutrition were measured in glasshouse using isotope dilution technique. The amount of soil Zn nutrient available to plants can be expressed in 'E' and 'L' values. Submerged conditions generally showed an increase in the 'E' and 'L' value compared to dry conditions. Mixed treatment with ZnSO 4 fertilizer is more efficient for Zn absorption than surface treatment. (author)

  20. System and technique for ultrasonic determination of degree of cooking

    Energy Technology Data Exchange (ETDEWEB)

    Bond, Leonard J [Richland, WA; Diaz, Aaron A [W. Richland, WA; Judd, Kayte M [Richland, WA; Pappas, Richard A [Richland, WA; Cliff, William C [Richland, WA; Pfund, David M [Richland, WA; Morgen, Gerald P [Kennewick, WA

    2007-03-20

    A method and apparatus are described for determining the doneness of food during a cooking process. Ultrasonic signal are passed through the food during cooking. The change in transmission characteristics of the ultrasonic signal during the cooking process is measured to determine the point at which the food has been cooked to the proper level. In one aspect, a heated fluid cooks the food, and the transmission characteristics along a fluid-only ultrasonic path provides a reference for comparison with the transmission characteristics for a food-fluid ultrasonic path.

  1. Recent Developments in the Speciation and Determination of Mercury Using Various Analytical Techniques

    Directory of Open Access Journals (Sweden)

    Lakshmi Narayana Suvarapu

    2015-01-01

    Full Text Available This paper reviews the speciation and determination of mercury by various analytical techniques such as atomic absorption spectrometry, voltammetry, inductively coupled plasma techniques, spectrophotometry, spectrofluorometry, high performance liquid chromatography, and gas chromatography. Approximately 126 research papers on the speciation and determination of mercury by various analytical techniques published in international journals since 2013 are reviewed.

  2. Radiation technique to determine early peopling of Brazil

    International Nuclear Information System (INIS)

    Watanabe, Shigueo; Ayta, Walter E.F.; Callata, Henry J.C.; Farias, Thiago M.B.; Gennari, Roseli F.; Etchevarne, Carlos A.

    2009-01-01

    Peopling American Continent and in particular of Brazil has been subject of research for a long time. With the results of dating of several pertinent materials many theories have been proposed. In Brazil, there is a National Park (Serra da Capivara Park) which is worldwide known due to thousands of wall paintings, most of them in rockshelters. N. Guidon, head of the Serra da Capivara National Park, found charcoal pellets in several archaeological sites and they were dated by radiocarbon technique. Ages ranging from 6 to 48 ka have been found. In one of the shelter a thin white covering was found that was proved to be calcite. This calcite was dated by Thermoluminescence and Electron Paramagnetic Resonance techniques and ages of 35 to 36 ka were obtained. In 2007, thin calcite covering wall paintings found in Iraquara County, Bahia state, has been dated. Ages of 50 ka have been obtained. The proposal of this work is that the early settlers crossed Atlantic Ocean from westernmost point of African Continent to easternmost point in Brazil more than 50000 years ago. The theory here proposed is possible once the distance between these two points is less than 3000 km distance far shorter than from Siberia to South America as proposed by other researchers.(author)

  3. Site index determination techniques for southern bottomland hardwoods

    Science.gov (United States)

    Brian Roy Lockhart

    2013-01-01

    Site index is a species-specific indirect measure of forest productivity expressed as the average height of dominant and codominant trees in a stand of a specified base age. It is widely used by forest managers to make informed decisions regarding forest management practices. Unfortunately, forest managers have difficulty in determining site index for southern US...

  4. Determination of rock fragmentation based on a photographic technique

    International Nuclear Information System (INIS)

    Dehgan Banadaki, M.M.; Majdi, A.; Raessi Gahrooei, D.

    2002-01-01

    The paper represents a physical blasting model in laboratory scale along with a photographic approach to describe the distribution of blasted rock materials. For this purpose, based on wobble probability distribution function, eight samples each weighted 100 kg,were obtained. Four pictures from four different section of each sample were taken. Then, pictures were converted into graphic files with characterizing boundary of each piece of rocks in the samples. Error caused due to perspective were eliminated. Volume of each piece of the blasted rock materials and hence the required sieve size, each piece of rock to pass through, were calculated. Finally, original blasted rock size distribution was compared with that obtained from the photographic method. The paper concludes with presenting an approach to convert the results of photographic technique into size distribution obtained by seine analysis with sufficient verification

  5. Non-Destructive Technique for Determining Mango Maturity

    OpenAIRE

    Salengke; Mursalim

    2013-01-01

    Mango (Mangifera indica L.) is an important tropical fruit that has great potential in international markets. Currently, major markets for mango include North America, Europe, and Japan. The acceptance of exported mango in destination countries depends largely on eating quality, which is affected by maturity at harvest. Mango maturity can be judged visually, based on skin color, or determined chemically based on soluble solids content, acid content, and solids:acid ratio....

  6. New technique for determining unavailability of computer controlled safety systems

    International Nuclear Information System (INIS)

    Fryer, M.O.; Bruske, S.Z.

    1984-04-01

    The availability of a safety system for a fusion reactor is determined. A fusion reactor processes tritium and requires an Emergency Tritium Cleanup (ETC) system for accidental tritium releases. The ETC is computer controlled and because of its complexity, is an excellent candidate for this analysis. The ETC system unavailability, for preliminary untested software, is calculated based on different assumptions about operator response. These assumptions are: (a) the operator shuts down the system after the first indication of plant failure; (b) the operator shuts down the system after following optimized failure verification procedures; or (c) the operator is taken out of the decision process, and the computer uses the optimized failure verification procedures

  7. Simulation techniques for determining reliability and availability of technical systems

    International Nuclear Information System (INIS)

    Lindauer, E.

    1975-01-01

    The system is described in the form of a fault tree with components representing part functions of the system and connections which reproduce the logical structure of the system. Both have the states intact or failed, they are defined here as in the programme FESIVAR of the IRS. For the simulation of components corresponding to the given probabilities, pseudo-random numbers are applied; these are numbers whose sequence is determined by the producing algorithm, but which for the given purpose sufficiently exhibit the behaviour of randomly successive numbers. This method of simulation is compared with deterministic methods. (HP/LH) [de

  8. Use of decision analysis techniques to determine Hanford cleanup priorities

    International Nuclear Information System (INIS)

    Fassbender, L.; Gregory, R.; Winterfeldt, D. von; John, R.

    1992-01-01

    In January 1991, the U.S. Department of Energy (DOE) Richland Field Office, Westinghouse Hanford Company, and the Pacific Northwest Laboratory initiated the Hanford Integrated Planning Process (HIPP) to ensure that technically sound and publicly acceptable decisions are made that support the environmental cleanup mission at Hanford. One of the HIPP's key roles is to develop an understanding of the science and technology (S and T) requirements to support the cleanup mission. This includes conducting an annual systematic assessment of the S and T needs at Hanford to support a comprehensive technology development program and a complementary scientific research program. Basic to success is a planning and assessment methodology that is defensible from a technical perspective and acceptable to the various Hanford stakeholders. Decision analysis techniques were used to help identify and prioritize problems and S and T needs at Hanford. The approach used structured elicitations to bring many Hanford stakeholders into the process. Decision analysis, which is based on the axioms and methods of utility and probability theory, is especially useful in problems characterized by uncertainties and multiple objectives. Decision analysis addresses uncertainties by laying out a logical sequence of decisions, events, and consequences and by quantifying event and consequence probabilities on the basis of expert judgments

  9. Determination of uteroplacental blood flow by a radionuclide technique

    International Nuclear Information System (INIS)

    Rosati, P.; Exacuostos, C.; Bellati, U.; Maini, C.L.; Bonetti, M.G.; Galli, G.

    1987-01-01

    The placental blood flow was determined using a non-invasive radioisotopic approach, with the intravenous administration of 113m In (37 MBq). The method was employed in 20 normal pregnancies, in 24 patients with intrauterine growth retardation, in 8 patients with iso-Rh-incompatibility and in 9 patients with gestational diabetes. In the group with intrauterine growth retardation 2 pregnancies with extensive fetal malformations were included. In one case without evident histological placental alteration the index was 3.94 at 34 weeks of gestation and 5.62 at 36 weeks of gestation. In the second one with placental infarcts the index was 3.46 at 38 weeks of gestation. Normal pregnancies showed a flow index of 5.50 ± 1.57 units compared to the pathological pregnancies value of 2.74 ± 0.90 units. The method is very well suited to clinical evaluation of placental blood flow. (author)

  10. A novel technique for detection efficiency determination of HPGe

    International Nuclear Information System (INIS)

    Tayyebi, Pouneh; Abbasi Davani, Fereydoun; Tabasi, Mohsen; Afarideh, Hossein

    2017-01-01

    In this work, we present an experimental method to determine the detection efficiency of HPGe when the reference source according to the geometry of interest is not accessible. We use known activity point sources (PS) of 152 Eu, 137 Cs, 241 Am and 133 Ba to find the detection efficiency for disc source (DS) geometry. It can be assumed that a DS consists of several PS's. Mapping the detector surface by means of 137 Cs PS shows that there is radial symmetry for detection efficiency vs. energy. Each radial distance on the detector surface contains some points, which can be considered as a PS. By selecting two points in two different radii and central point, the DS efficiency is obtained. To ensure that the method is correct, we measure the activity of a known activity DS considering DS efficiency obtained by PS's. The DS comprises 137 Cs, 133 Ba and 60 Co. The relative difference between the measured and the reported activity of DS in most energies is less than 5%. - Highlights: • Exact knowledge of the detector dimension is not necessary • There is no need to have standard source according to the sample • It is a simple method that can be done at any laboratories

  11. An evaluation of back stress determination techniques in metals

    International Nuclear Information System (INIS)

    Jones, W.B.; Rohde, R.W.

    1983-01-01

    The desire to develop unified creep-plasticity (UCP) models come from the necessity to design advanced nuclear reactor components for service under conditions which include combined creep and low cycle fatigue. These models should also be physically based since they would be used to extrapolate from laboratory data to predict long service lives. An approach to UCP modelling centers on the hypothesis that the inelastic strain rate is determined by a balance between the competing processes of work hardening and recovery. One class of UCP models is characterized by a power law relationship between strain rate and stress. A state variable common to these models characterizes the isotropic hardening and is allowed to evolve with history according to simultaneous work hardening and recovery. In order to treat behaviours unique to unloading or reverse loading conditions, several models also include a kinematic hardening variable which is also allowed to evolve according to a balance of work hardening and recovery. Such a treatment of inelastic deformation can mathematically treat a wide variety of behaviors. The measured response of 316SS and A800 indicates that the kinematic variable must, in steady state, be taken as a constant fraction (about 0.8) of the applied stress. This experimental result makes it impossible for the simple power law type expression to properly predict the commonly observed power law breakdown behavior in most metals and alloys. It is proposed that an expression for total inelastic strain rate involving the sum of two separate strain rate contributions is more appropriate. Acknowledging that separate expressions and separate mechanisms dominate low stress (engineering service) conditions and high stress (laboratory test) conditions requires that more emphasis be placed on long time, low stress laboratory testing. (orig.)

  12. Melt Motion Due to Peltier Marking During Bridgman Crystal Growth with an Axial Magnetic Field

    Science.gov (United States)

    Sellers, C. C.; Walker, John S.; Szofran, Frank R.; Motakef, Shariar

    2000-01-01

    This paper treats a liquid-metal flow inside an electrically insulating cylinder with electrically conducting solids above and below the liquid region. There is a uniform axial magnetic field, and there is an electric current through the liquid and both solids. Since the lower liquid-solid interface is concave into the solid and since the liquid is a better electrical conductor than the adjacent solid, the electric current is locally concentrated near the centerline. The return to a uniform current distribution involves a radial electric current which interacts with the axial magnetic field to drive an azimuthal flow. The axial variation of the centrifugal force due to the azimuthal velocity drives a meridional circulation with radial and axial velocities. This problem models the effects of Peltier marking during the vertical Bridgman growth of semiconductor crystals with an externally applied magnetic field, where the meridional circulation due to the Peltier Current may produce important mixing in the molten semiconductor.

  13. Directional solidification of Zn-Al-Cu eutectic alloy by the vertical Bridgman method

    Directory of Open Access Journals (Sweden)

    Büyük U.

    2015-01-01

    Full Text Available In the present work, the effect of growth rate and temperature gradient on microstructure and mechanical properties of Zn-7wt.%Al-4wt.%Cu eutectic alloy has been investigated. Alloys prepared under steady-state conditions by vacuumed hot filing furnace. Then, the alloys were directionally solidified upward with different growth rates (V=11.62-230.77 mm/s at a constant temperature gradient (G=7.17 K/mm and with different temperature gradients (G=7.17-11.04 K/mm at a constant growth rate (V=11.62 mm/s by a Bridgman furnace. The microstructures were observed to be lamellae of Zn, Al and broken lamellae CuZn4 phases from quenched samples. The values of eutectic spacing, microhardness and ultimate tensile strength of alloys were measured. The dependency of the microstructure and mechanical properties on growth rate and temperature gradient were investigated using regression analysis.

  14. Thermoelectric properties of Bi2SexTe3-x prepared by Bridgman method

    International Nuclear Information System (INIS)

    Keawprak, N.; Lao-ubol, S.; Eamchotchawalit, C.; Sun, Z.M.

    2011-01-01

    Highlights: → Bi 2 Se x Te 3-x with various Se concentrations grown by Bridgman method was prepared. → The electrical conductivity was found to decrease with increasing Se content. → The Seebeck coefficient was not influenced by the substitution of Te with Se. → The electronic thermal conductivity exhibited a decrease with increasing Se. → The highest of dimensionless figure of merit (ZT) was measure to be 1.2. - Abstract: Bi 2 Se x Te 3-x crystals with various x values were grown by Bridgman method. The electrical conductivity, σ, was found to decrease with increasing Se content. The highest σ of 1.6 x 10 5 S m -1 at room temperature was reached at x = 0.12 with a growth rate of 0.8 mm h -1 . The Seebeck coefficient, S, was less dependent on Se content, all with positive values showing p-type characteristics, and the highest S was measured to be 240 μV K -1 at x = 0.24. The lowest thermal conductivity, κ, was 0.7 W m -1 K -1 at x = 0.36. The electronic part of κ, κ el , showed a decrease with increasing Se content, which implies that the hole concentration as the main carriers was reduced by the addition of Se. The highest dimensionless figure of merit, ZT, at room temperature was 1.2 at x = 0.36, which is attributed to the combination of a rather high electrical conductivity and Seebeck coefficient and low thermal conductivity.

  15. Determining Plutonium Mass in Spent Fuel with Nondestructive Assay Techniques -- Preliminary Modeling Results Emphasizing Integration among Techniques

    International Nuclear Information System (INIS)

    Tobin, S.J.; Fensin, M.L.; Ludewigt, B.A.; Menlove, H.O.; Quiter, B.J.; Sandoval, N.P.; Swinhoe, M.T.; Thompson, S.J.

    2009-01-01

    There are a variety of motivations for quantifying Pu in spent (used) fuel assemblies by means of nondestructive assay (NDA) including the following: strengthen the capabilities of the International Atomic Energy Agencies to safeguards nuclear facilities, quantifying shipper/receiver difference, determining the input accountability value at reprocessing facilities and providing quantitative input to burnup credit determination for repositories. For the purpose of determining the Pu mass in spent fuel assemblies, twelve NDA techniques were identified that provide information about the composition of an assembly. A key point motivating the present research path is the realization that none of these techniques, in isolation, is capable of both (1) quantifying the elemental Pu mass of an assembly and (2) detecting the diversion of a significant number of pins. As such, the focus of this work is determining how to best integrate 2 or 3 techniques into a system that can quantify elemental Pu and to assess how well this system can detect material diversion. Furthermore, it is important economically to down-select among the various techniques before advancing to the experimental phase. In order to achieve this dual goal of integration and down-selection, a Monte Carlo library of PWR assemblies was created and is described in another paper at Global 2009 (Fensin et al.). The research presented here emphasizes integration among techniques. An overview of a five year research plan starting in 2009 is given. Preliminary modeling results for the Monte Carlo assembly library are presented for 3 NDA techniques: Delayed Neutrons, Differential Die-Away, and Nuclear Resonance Fluorescence. As part of the focus on integration, the concept of 'Pu isotopic correlation' is discussed and the role of cooling time determination.

  16. Stress wave techniques for determining quality of dimensional lumber from switch ties

    Science.gov (United States)

    K. C. Schad; D. E. Kretschmann; K. A. McDonald; R. J. Ross; D. W. Green

    1995-01-01

    Researchers at the Forest Products Laboratory, USDA Forest Service, have been studying nondestructive techniques for evaluating the strength of wood. This report describes the results of a pilot study on using these techniques to determine the quality of large dimensional lumber cut from switch ties. First, pulse echo and dynamic (transverse vibration) techniques were...

  17. Determining the Number of Factors in P-Technique Factor Analysis

    Science.gov (United States)

    Lo, Lawrence L.; Molenaar, Peter C. M.; Rovine, Michael

    2017-01-01

    Determining the number of factors is a critical first step in exploratory factor analysis. Although various criteria and methods for determining the number of factors have been evaluated in the usual between-subjects R-technique factor analysis, there is still question of how these methods perform in within-subjects P-technique factor analysis. A…

  18. Comparison of protein fermentation characteristics in rumen fluid determined with the gas production technique and the nylon bag technique

    NARCIS (Netherlands)

    Cone, J.W.; Rodrigues, M.A.M.; Guedes, C.M.; Blok, M.C.

    2009-01-01

    In this study, a modified version of the gas production technique was used to determine protein fermentation characteristics in rumen fluid of 19 feedstuffs. Performing the incubations in a N-free environment, and with an excess of rapidly fermentable carbohydrates, made N the limiting factor to

  19. The use of different techniques for determination of pitting corrosion potential of austenitic stainless steel

    International Nuclear Information System (INIS)

    Eskelinen, P.; Forsen, O.; Onnela, J.; Ylaesaari, S.; Haenninen, H.

    1992-01-01

    Three different techniques for pitting corrosion potential measurement on austenitic stainless steel (Fe18Cr10Ni) were compared: conventional polarization method, a new Avesta electrochemical corrosion measurement cell and a scratch technique. Special attention was paid to the effects of crevice corrosion during pitting corrosion potential measurement and to their elimination. Development of a rapid test technique for reliable pitting corrosion potential determination was aimed at and resulted from comparison of the different techniques

  20. Determination of 210Pb in marine sediment core- A comparison between alpha and gamma techniques

    International Nuclear Information System (INIS)

    Zal Uyun Wan Mahmood; Yii Mei Wo; Zaharudin Ahmad

    2010-01-01

    The most commonly used techniques of alpha and gamma spectrometry were performed to measure 210 Pb activity in marine sediment core as a comparison. Alpha analytical technique measured the activity of 210 Pb from its in-grow grand-daughter 210 Po after a chemical separation, assuming radioactive equilibrium between the two radionuclides. Meanwhile, gamma analysis technique allows direct measurement, non-destructive and no preliminary chemical separation. Through the comparison, it is found that both alpha and gamma analysis techniques were slightly difference. Overall, the results from alpha analytical technique were basically higher than those from the gamma analytical techniques. Some logical argument had been discussed to explain this situation. In routine analysis, the analytical technique used should be chosen carefully based on advantages and disadvantages of the each technique and analysis requirements. Therefore, it is recommended to determine exactly the needs and purpose of analysis and to know the sample history before decide the appropriate analytical technique. (author)

  1. Influence of Crucible Support Rod on the Growth Rate and Temperature Gradient in a Bridgman Growth of Tin Crystal

    OpenAIRE

    IMASHIMIZU, Yuji; MIURA, Koji; KAMATA, Masaki; WATANABE, Jiro

    2003-01-01

    Bridgman growth of tincrystal was carried out in a graphite crucible that was fixed on a quartz support rod or a copper one. The growth rate and axial temperature distribution were examined by recording the temperature variation with time at each of four prescribed positions in the solid-liquidsystem during solidification, l) Actual growth rate of crystal increased with progress of solidification while the furnace elevated at a constant rate, but the tendency was different depending on the ty...

  2. Determination of biologically active phenols and polyphenols in various objects by chromatographic techniques

    International Nuclear Information System (INIS)

    Kochetova, M V; Semenistaya, E N; Larionov, Oleg G; Revina, A A

    2007-01-01

    Chromatographic techniques for determination of biologically active phenols and polyphenols are considered. Various methods for sample preparation and detection are compared. The advantages of high performance liquid chromatography with spectrophotometric detection for determination of antioxidants are demonstrated. Data on determination of biologically active phenols and polyphenols published in the period from 1995 to 2005 are analysed.

  3. The determination of acoustic reflection coefficients by using cepstral techniques, II: Extensions of the technique and considerations of accuracy

    Science.gov (United States)

    Bolton, J. S.; Gold, E.

    1986-10-01

    In a companion paper the cepstral technique for the measurement of reflection coefficients was described. In particular the concepts of extraction noise and extraction delay were introduced. They are considered further here, and, in addition, a means of extending the cepstral technique to accommodate surfaces having lengthy impulse responses is described. The character of extraction noise, a cepstral component which interferes with reflection measurements, is largely determined by the spectrum of the signal radiated from the source loudspeaker. Here the origin and effects of extraction noise are discussed and it is shown that inverse filtering techniques may be used to reduce extraction noise without making impractical demands of the electrical test signal or the source loudspeaker. The extraction delay, a factor which is introduced when removing the reflector impulse response from the power cepstrum, has previously been estimated by a cross-correlation technique. Here the importance of estimating the extraction delay accurately is emphasized by showing the effect of small spurious delays on the calculation of the normal impedance of a reflecting surface. The effects are shown to accord with theory, and it was found that the real part of the estimated surface normal impedance is very nearly maximized when the spurious delay is eliminated; this has suggested a new way of determining the extraction delay itself. Finally, the basic cepstral technique is suited only to the measurement of surfaces whose impulse responses are shorter than τ, the delay between the arrival of the direct and specularly reflected components at the measurement position. Here it is shown that this restriction can be eliminated, by using a process known as cepstral inversion, when the direct cepstrum has a duration less than τ and cepstral aliasing is insignificant. It is also possible to use this technique to deconvolve a signal from an echo sequence in the time domain, an operation

  4. Comparison of techniques for determination of soluble sugars used in feed for ruminant nutrition

    Directory of Open Access Journals (Sweden)

    Cândida Camila dos Reis

    2015-02-01

    Full Text Available This study aims to evaluate different techniques for determination of soluble sugars (fraction CA in foods used for ruminant nutrition. Feed analyzed were: sugar-cane, bermuda grass, corn meal and soybean meal. Dry matter (DM, ash, ether extract (EE and crude protein (CP were determined to make possible the calculation of total carbohydrates concentration in the samples. The soluble carbohydrate fraction were determined in 15 repetitions of each sample by two different analytical techniques. One technique based on soluble carbohydrates extraction and its quantification by spectrophotometry after chelation of the sugar with anthrone; and another one that uses phenol as the chelating agent. The experiment were conducted in a completely randomized design and the data submitted to the two-factor factorial analysis of variance (? = 0.05, with the different feeds and the two techniques as factors. There was no statistical difference between techniques, but the effect of the feed and the interaction feed x technique were significant. So, a new analysis of variance was conducted to test the difference between techniques in each feed separately. Only soybean meal did not show statistical difference between the water soluble sugars determined by the two techniques.

  5. Estudio de la incorporación de iones de Er y Nd en galio antimonio crecido por el método Bridgman

    Directory of Open Access Journals (Sweden)

    Plaza, J. L.

    2000-08-01

    Full Text Available In this work the study of GaSb crystals grown by the Bridgman method doped with Er and Nd with different concentrations has been carried out. Atomic absorption analysis have been developed for obtaining the effective segregation coefficient of the two dopants along the growth direction of the material. The resistivity, mobility and density of carriers were obtained by the van der Pauw technique for the different dopant concentrations. The energy dispersive X ray analysis (EDX and the scanning electron microscope (SEM have demonstrated the presence of precipitates made from Sb and rare earth elements for the highest dopant concentrations. Cathodoluminescence (CL analysis have proved that the rare earth elements have a reduction effect of native defects in GaSb.

    En este trabajo se ha realizado el estudio de cristales de GaSb crecidos por el método Bridgman y dopados con Er y Nd con distintas concentraciones. Se han realizado análisis de absorción atómica pudiéndose obtener el coeficiente de segregación efectivo de ambos dopantes a lo largo de la dirección de crecimiento del material. Mediante medidas de efecto Hall se ha determinado el tipo de portadores mayoritarios (huecos así como los valores de la movilidad, la densidad de portadores y la resistividad para cada una de las concentraciones. Los análisis de dispersión de energías de rayos X (EDAX y de microscopio electrónico de barrido (SEM han demostrado la presencia de agregados formados por los iones de tierras raras y Sb para las concentraciones de dopante más altas. La reducción de los defectos nativos tales como las vacantes de Ga y Ga en posición de Sb por los iones de Er ha sido también demostrado a través de análisis de catodoluminiscencia.

  6. Comparison of dye dilution method to radionuclide techniques for cardiac output determination in dogs

    International Nuclear Information System (INIS)

    Eng, S.S.; Robayo, J.R.; Porter, W.; Smith, R.E.

    1980-01-01

    A study was undertaken to identify the most accurate /sup 99m/Tc-labeled radiopharmaceutical and to determine the accuracy of a noninvasive radionuclide technique or cardiac output determinations. Phase I employed sodium pertechnetate, stannous pyrophosphate with sodium pertechnetate, /sup 99m/Tc red blood cells, and /sup 99m/Tc human serum albumin as radionuclide tracers. Cardiac output was determined by the dye dilution method and then by the invasive radionuclide technique. A pairied t test and regression analysis indicated that /sup 99m/Tc human serum albumin was the most accurate radiopharmaceutical for cardiac output determinations, and the results compared favorably to those obtained by the dye dilution method. In Phase II, /sup 99m/Tc human serum albumin was used as the radionuclide tracer for cardiac output determinations with the noninvasive technique. The results compared favorably to those obtained by the dye dilution method

  7. Techniques for rapid determination of effects of synergy between radionuclides and pollutants

    International Nuclear Information System (INIS)

    Saas, A.; Grauby, A.

    1975-01-01

    The authors present a number of chromatographic techniques for rapid determination of synergy between radionuclides and various compounds in water. The first technique consists in studying how the chemical equilibrium of iodine varies in the presence of various organic and mineral compounds. The second makes it possible to define the effects of synergy within a given hydrographic basin. A third technique deals with the effects of synergy in ground water in the presence of various types of irrigation water. Finally, to complete this set of techniques, the authors define the mobility potential of a radionuclide in a given aqueous effluent

  8. ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MELOXICAM IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL SAMPLES

    Directory of Open Access Journals (Sweden)

    Aisha Noreen

    2016-06-01

    Full Text Available Meloxicam (MX belongs to the family of oxicams which is the most important group of non steroidal anti-inflammatory drugs (NSAIDs and is widely used for their analgesics and antipyretic activities. It inhibits both COX-I and COX-II enzymes with less gastric and local tissues irritation. A number of analytical techniques have been used for the determination of MX in pharmaceutical as well as in biological fluids. These techniques include titrimetry, spectrometry, chromatography, flow injection spectrometry, fluorescence spectrometry, capillary zone electrophoresis and electrochemical techniques. Many of these techniques have also been used for the simultaneous determination of MX with other compounds. A comprehensive review of these analytical techniques has been done which could be useful for the analytical chemists and quality control pharmacists.

  9. Automated urinalysis technique determines concentration of creatine and creatinine by colorimetry

    Science.gov (United States)

    Rho, J. H.

    1967-01-01

    Continuous urinalysis technique is useful in the study of muscle wastage in primates. Creatinine concentration in urine is determined in an aliquot mixture by a color reaction. Creatine is determined in a second aliquot by converting it to creatinine and measuring the difference in color intensity between the two aliquots.

  10. Carbon/Hydrogen ratio determination in hydrocarbons and its mixtures by electron backscattering technique

    International Nuclear Information System (INIS)

    Padron, I.; Desdin, L.F.; Navarro, A.; Fuentes, M.

    1996-01-01

    A method carbon/hydrogen ratio (C/H) determination in hydrocarbons and its mixtures was improved using the electron backscattering technique. Besides the hetero atoms (S,O and N) influence in petroleum is studied for being able to determinate the C/H ratio in cuban petroleum with high sulphur contents

  11. Nuclear techniques for the determination of protein content in plant material

    International Nuclear Information System (INIS)

    Niemann, E.G.

    1980-01-01

    Elemental analysis for nitrogen has gained in importance over the last decade, as protein improvement and protein control in food and feed has come to be recognized as one of the most promising ways of overcoming deficiencies in food production and distribution. The need for fast and reliable screening methods has stimulated the improvement and automation of classic chemical methods for protein and nitrogen determination and, on the other hand, the development and adaptation of physical and nuclear analysis procedures. After about ten years of work this process has come to a stage where a critical evaluation of the existing methods seems necessary and justified. The present review describes and compares nuclear techniques for nitrogen determination in plant material. These include activation analysis techniques, based on various nuclear reactions, initiated by fast and thermal neutrons, energetic photons, protons, deuterons and α-particles. Other nuclear methods have been applied for nitrogen or protein determination, like ESCA, PIXE, NMR, NQR and Moessbauer spectroscopy, some of which possess good potential as screening methods. Depending on the needs, such as sample size, analysis rate and postulated accuracy, different nuclear techniques may be selected today for nitrogen screening. Some of the techniques discussed have additional potential for carbon or oxygen determination, for measuring depth or lateral N distribution, or for the recognition of the type of chemical N binding. Though most if not all techniques need further development for routine application, they are able to compete with chemical techniques in cost, rate and accuracy. (author)

  12. Isotopic Determination of Nuclear Materials Using Nuclear Fission Track Registration Technique and Thermal Ionization Mass Spectrometric Technique

    International Nuclear Information System (INIS)

    Jeon, Young Sin; Pyo, Hyeong Yeol; Park, Yong Joon; Song, Kyu Seok; Kim, Won Ho; Jee, Kwang Yong

    2007-05-01

    It is very important to develope the technology for the determination of isotopic ratios of hot particles( 234 U, 235 U, 236 U etc.) detected from swipe samples of various nuclear facilities. This technology is highly competitive internationally and has to be established independently as long as our government maintains atomic energy and treats nuclear materials. In this text, sample pretreatment procedure, gamma-ray counting, alpha or fission track techniques, isotopic analysis of U and Pu, background problems and detection limits for mass determination, and their application to the real swipe sample were described with detailed procedure. This technology would contribute to the Korean economy's high growth rate as well as to superiority of government's leading research and development programs if successfully established

  13. Mass determination of U-233 and Pu-239 by gamma spectrometry technique

    International Nuclear Information System (INIS)

    Moraes, M.A.P.V. de; Pugliesi, R.

    1988-09-01

    The gamma spectrometry technique has been used for masses determinations of uranium-233 and plutonium-239, granted by AERE-HARWELL. A high purity Ge semicondutor detector was used and the total efficiency curve was obtained for the counting system in the energy range 13 KeV to 135 KeV. The calculated values for the masses compared with that obtained by means of gravimetry technique. (author) [pt

  14. Determination of mineral matter distribution in a coal seam using O sub 2 chemisorption technique

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, A.D.; Goulet, J.-C.; Grandsen, J.; Price, J.T.; Furimsky, E. (CANMET, Ottawa, ON (Canada). Energy Research Laboratories)

    1990-08-01

    A series of samples taken from different depths of the seam of a bituminous coal in Western Canada was used to determine the mineral matter distribution. The measurements were carried out using the O{sub 2} chemisorption based on a thermogravimetric technique. The O{sub 2} chemisorption increased with decreasing mineral matter content. The employed technique was found to be suitable for identifying the portion of coal seam least contaminated with mineral matter. 5 refs., 3 figs., 1 tab.

  15. Determination Of Natural Boron Concentration In Coffee Leaves, Using de Autobiography by Neutron Capture Technique

    International Nuclear Information System (INIS)

    Loria, L. G.; Jimenez, R.; Thellier, M.

    1999-01-01

    Determination of natural boron concentration in coffee leaves, using the autoradiography, by neutron capture technique. The boron absorption coefficient in young coffee leaves was measured using autoradiography by neutron capture. In two experiments carried out in April and November, 1996, it was found that the coefficient varies between 0.9 and 5.3 nmol/h. the concentration of natural boron in coffee leaves in regard to age, symptoms and treatment received was also studied, using the same technique. (Author) [es

  16. Liquid scintillation counting techniques for the determination of some alpha emitting actinides: a review

    International Nuclear Information System (INIS)

    Mirashi, N.N.; Chander, Keshav; Aggarwal, S.K.

    2000-12-01

    The present report is a review of the work on liquid scintillation counting techniques, for the determination of alpha emitting actinides like uranium, plutonium, americium etc; for the last three decades (1970-1999). It covers the progress that has taken place in conventional liquid scintillation counting employing various solvents, scintillators and extractants. There is gradual development in instrumentation from integral counting of alpha emitters to alpha liquid scintillation spectrometry to resolve and identify different alpha emitters. These advancements have led to Pulse Shape Analysis (PSA) and Photon Electron Rejecting Alpha Liquid Scintillation Spectrometry (PERALS) techniques for the determination of the alpha emitters in the presence of beta and gamma activity. These techniques allow the determination of actinides at very low levels which has increased their applications to almost all the fields of chemistry; be it biomedical, environmental, geological or process chemistry of nuclear fuels. The development of biphasic technique using various extractants to separate different elements and counting in presence of one another has been made possible. Inorganic scintillators have been recently developed which have the advantage of eliminating effects of quenching and presence of beta/gamma emitting actinides. This review will serve as a reference to those who want to carry out work in the field of determination of actinides using liquid scintillation counting techniques. (author)

  17. [Growth of codoped CdWO4 crystals by Bridgman method and their optical spectra].

    Science.gov (United States)

    Yu, Can; Xia, Hai-Ping; Wang, Dong-Jie; Chen, Hong-Bing

    2011-09-01

    The CdWO4 crystals with good quality in the size of Phi25 mm x 120 mm, doped with Co in 0.5% molar fraction in the raw composition, were grown by the Bridgman method by taking -70 degrees C x cm(-1) of solid-liquid interface and -0.50 mm x h(-1) growth rate. The crystal presents transparence and deep blue. The X-ray diffraction (XRD) was used to characterize the crystals. Three absorption peaks at 518, 564 and 655 nm respectively, which are attributed to the overlapping of 4 T1 (4F) --> 4A2 (4F) and 4 T1 (4F) --> 4 T1 (4P) of Co2+ octahedrons, and a wide band centered at 1 863 nm, which is attributed to 4Ti (4F) --> 4 T2 (4F), was observed. The absorption results indicated that the Co ions presented +2 valence in crystal and located within the distorted oxygen octahedrons. The crystal-field parameter D(q) and the Racah parameter B were estimated to be 990 and 726.3 cm(-1) respectively based on the absorption spectra. A fluorescence emission at 778 nm (4T1 (4P) --> 4 T1 (4F)) for codoped CdWO4 crystals was observed under excitation by 520 nm light. It can be deduced from the changes in absorption and emission intensity of different parts of crystal that the concentration of Co2+ ion in crystal increased along growing direction and the effective distribution coefficient of Co2+ ion in CdWO4 crystal is less than 1.

  18. Chemical etching of a GaSb crystal incorporated with Mn grown by the Bridgman method under microgravity conditions

    International Nuclear Information System (INIS)

    Chen Xiaofeng; Chen Nuofu; Wu Jinliang; Zhang Xiulan; Chai Chunlin; Yu Yude

    2009-01-01

    A GaSb crystal incorporated with Mn has been grown by the Bridgman method on the Polizon facility onboard the FOTON-M3 spacecraft. Structural defects and growth striations have been successfully revealed by the chemical etching method. By calculating various parameters of the convection, the striation patterns can be explained, and the critical value of the Taylor number, which characterizes the convective condition of the rotating magnetic field induced azimuthal flow, was shown. The stresses generated during crystal growth can be reflected by the observations of etch pit distribution and other structural defects. Suggestions for improving the space experiment to improve the quality of the crystal are given. (semiconductor materials)

  19. Chemical etching of a GaSb crystal incorporated with Mn grown by the Bridgman method under microgravity conditions

    Energy Technology Data Exchange (ETDEWEB)

    Chen Xiaofeng; Chen Nuofu; Wu Jinliang; Zhang Xiulan; Chai Chunlin; Yu Yude, E-mail: xfchen@semi.ac.c, E-mail: nfchen@semi.ac.c [Key Laboratory of Semiconductor Materials and Devices, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083 (China)

    2009-08-15

    A GaSb crystal incorporated with Mn has been grown by the Bridgman method on the Polizon facility onboard the FOTON-M3 spacecraft. Structural defects and growth striations have been successfully revealed by the chemical etching method. By calculating various parameters of the convection, the striation patterns can be explained, and the critical value of the Taylor number, which characterizes the convective condition of the rotating magnetic field induced azimuthal flow, was shown. The stresses generated during crystal growth can be reflected by the observations of etch pit distribution and other structural defects. Suggestions for improving the space experiment to improve the quality of the crystal are given. (semiconductor materials)

  20. Novel technique for determination of alloy composition with the help of chronopotentiometry

    International Nuclear Information System (INIS)

    Rizwan, R.; Mehmood, M.

    2006-01-01

    Single phase gamma (Ni/sub 5/Zn/sub 21/) nanocrystalline zinc-nickel alloy coatings were prepared by electrodeposition in chloride bath. Cyclic voltammetry as well as reverse Chronopotentiometry was performed on platinum substrate. Both of these techniques are well known for determination of phases present in alloy in electrochemistry. A new model is introduced for determining composition of the electrodeposited alloy (Zn-Ni) with the help of Chronopotentiometry. EDX of deposits was also performed. Relative percentages of zinc and nickel determined from Chronopotentiometry were almost same to the results obtained from EDX. So by use of this model, Chronopotentiometry can be used as useful characterization technique for in-situ determination of composition during electrodeposition. X -ray diffraction was performed and it confirms the presence of single phase deposits. Current efficiency of the deposits remain above 90%. Surface compactness of deposits is verified with the help of SEM. (author)

  1. A simple technique to determine the size distribution of nuclear crater fallback and ejecta

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, II, Brooks D [U.S. Army Engineer Nuclear Cratering Group, Lawrence Radiation Laboratory, Livermore, CA (United States)

    1970-05-15

    This report describes the results of an investigation to find an economic method for determining the block size distribution of nuclear crater fallback and ejecta. It is shown that the modal analysis method of determining relative proportions can be applied with the use of a special sampling technique, to provide a size distribution curve for clastic materials similar to one obtainable by sieving and weighing the same materials.

  2. A simple technique to determine the size distribution of nuclear crater fallback and ejecta

    International Nuclear Information System (INIS)

    Anderson, Brooks D. II

    1970-01-01

    This report describes the results of an investigation to find an economic method for determining the block size distribution of nuclear crater fallback and ejecta. It is shown that the modal analysis method of determining relative proportions can be applied with the use of a special sampling technique, to provide a size distribution curve for clastic materials similar to one obtainable by sieving and weighing the same materials

  3. Evaluating Eye Drop Instillation Technique and Its Determinants in Glaucoma Patients

    Directory of Open Access Journals (Sweden)

    Xinbo Gao

    2018-01-01

    Full Text Available Aim. To evaluate eye drop instillation technique and to explore its determinants in glaucoma patients. Methods. One hundred and thirteen patients diagnosed with glaucoma and self-administering topical antiglaucoma eye drops for at least 1 month were evaluated. All patients instilled artificial tear solution in one eye as they would do at home. The whole process was evaluated by two study staff. A comprehensive score system associated with eye drop instillation techniques was used to quantify the instillation technique and explore its determinants such as demographic and clinical characteristics. Results. Half of the patients (48.67% finished the administration of eye drop on first attempt.1.7 eye drops were squeezed out on average. 43 patients (37.17% got contact with ocular surface or adnexa. Only 19.7% patients had eye drop instillation techniques being defined as well. 11 patients (9.7% had prior instruction regarding using eye drops, while only 4 patients knew to occlude the tear duct by pressing the dacryocyst area. Older age and worse visual acuity were found to be independent risk factors for worse instillation technique. Conclusions. Eye drop instillation technique in glaucoma patients deserves great attention from eye care practitioners during their lifelong follow-up, especially those aged older and have worse visual acuity.

  4. Determination of some trace elements in biological samples using XRF and TXRF techniques

    International Nuclear Information System (INIS)

    Khuder, A.; Karjou, J.; Sawan, M. K.

    2006-07-01

    XRF and TXRF techniques were successfully used for the multi-element determination of trace elements in whole blood and human head hair samples. This was achieved by the direct analysis using XRF technique with different collimation units and by the optimized chemical procedures for TXRF analysis. Light element of S and P were preferably determined by XRF with primary x-ray excitation, while, elements of K, Ca, Fe, and Br were determined with a very good accuracy and precision using XRF with Cu- and Mo-secondary targets. The chemical procedure dependent on the preconcentration of trace elements by APDC was superiorly used for the determination of traces of Ni and Pb in the range of 1.0-1.7 μg/dl and 11-23 μg/dl, respectively, in whole blood samples by TXRF technique; determination of other elements as Cu and Zn was also achievable using this approach. Rb in whole blood samples was determined directly after the digestion of samples using PTFE-bomb for TXRF analysis. (author)

  5. Microhardness technique for determination of radiation hardening in austenitic stainless steel using

    International Nuclear Information System (INIS)

    Hofman, A.

    1995-01-01

    The use of microhardness technique to determine the radiation hardening has been studied. Microhardness measurements have been conducted on austenitic stainless steel 0H18N10T irradiated up to 2·10 23 nm -2 . It was determined that the increase in microhardness varies directly with the measured increase in the 0,2% offret yield strength and has been found that microhardness technique may be an effective tool to measurements of radiation induced hardening. Based on the results and Cahoon's relation that σ 0,2 (MPa)=3,27HV(0,1) n method for evaluating the yield stress σ 0,2 by microhardness technique is analyzed. 14 refs., 3 figs., 3 tabs

  6. Residual stress determination of rail tread using a laser ultrasonic technique

    International Nuclear Information System (INIS)

    Wang, Jing; Feng, Qibo

    2015-01-01

    A non-destructive method for measuring the residual stress on rail tread that uses a laser-generated ultrasonic technique is proposed. The residual stress distribution of different parts on both the new rail and used rail were examined. The surface acoustic waves (SAWs) are excited by a scanning line laser and detected by a laser ultrasonic detection system. A digital correlation method was used for calculating the changes in velocity of SAWs, which reflects the stress distribution. A wavelet de-noising technique and a least square fit were used for signal processing to improve the measurement accuracy. The effects of ultrasonic propagation distance and surface roughness on the determination of residual stress were analyzed and simulated. Results from the study demonstrate that the stress distribution results are accordant with the practical situation, and the laser-generated SAWs technique is a promising tool for the determination of residual stress in the railway inspection and other industrial testing fields. (paper)

  7. New resin gel for uranium determination by diffusive gradient in thin films technique

    Czech Academy of Sciences Publication Activity Database

    Gregušová, Michaela; Dočekal, Bohumil

    2011-01-01

    Roč. 684, 1-2 (2011), s. 142-146 ISSN 0003-2670 R&D Projects: GA ČR GAP503/10/2002 Institutional research plan: CEZ:AV0Z40310501 Keywords : diffusive gradient in thin film technique * 8-hydroxyquinoline resin gel * uranium determination Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.555, year: 2011

  8. Aperture Determination in the LHC Based on an Emittance Blowup Technique with Collimator Position Scan

    CERN Document Server

    Assmann, R W; del Carmen Alabau, M; Giovannozzi, M; Muller, GJ; Redaelli, S; Schmidt, F; Tomas, R; Wenninger, J; Wollmann, D

    2011-01-01

    A new method to determine the LHC aperture was proposed. The new component is a collimator scan technique that refers the globally measured aperture limit to the shadow of the primary collimator, expressed in sigmas of rms beam size. As a by-product the BLM response to beam loss is quantified. The method is described and LHC measurement results are presented.

  9. A technique for determining the deuterium/hydrogen contrast map in neutron macromolecular crystallography.

    Science.gov (United States)

    Chatake, Toshiyuki; Fujiwara, Satoru

    2016-01-01

    A difference in the neutron scattering length between hydrogen and deuterium leads to a high density contrast in neutron Fourier maps. In this study, a technique for determining the deuterium/hydrogen (D/H) contrast map in neutron macromolecular crystallography is developed and evaluated using ribonuclease A. The contrast map between the D2O-solvent and H2O-solvent crystals is calculated in real space, rather than in reciprocal space as performed in previous neutron D/H contrast crystallography. The present technique can thus utilize all of the amplitudes of the neutron structure factors for both D2O-solvent and H2O-solvent crystals. The neutron D/H contrast maps clearly demonstrate the powerful detectability of H/D exchange in proteins. In fact, alternative protonation states and alternative conformations of hydroxyl groups are observed at medium resolution (1.8 Å). Moreover, water molecules can be categorized into three types according to their tendency towards rotational disorder. These results directly indicate improvement in the neutron crystal structure analysis. This technique is suitable for incorporation into the standard structure-determination process used in neutron protein crystallography; consequently, more precise and efficient determination of the D-atom positions is possible using a combination of this D/H contrast technique and standard neutron structure-determination protocols.

  10. Determination of the dose of traffic in HDR brachytherapy with ALANINE/R PE technique

    International Nuclear Information System (INIS)

    Guzman Calcina, C. S.; Chen, F.; Almeida, A. de; Baffa, O.

    2001-01-01

    It determines, experimentally, the dose of traffic in brachytherapy for High Dose Rate (HDR), using for the first-time the Electronic Paramagnetic Resonance (EPR) technique with alanine detectors. The value obtained is the published next to obtained using lithium fluoride thermoluminescent dosimeters [es

  11. Evaluation of techniques for determining the density of fine woody debris

    Science.gov (United States)

    Becky Fasth; Mark E. Harmon; Christopher W. Woodall; Jay. Sexton

    2010-01-01

    Evaluated various techniques for determining the density (i.e., bulk density) of fine woody debris during forest inventory activities. It was found that only experts in dead wood inventory may be able to identify fine woody debris stages of decay. Suggests various future research directions such as...

  12. Application of washed rumen technique for rapid determination of fasting heat production in steers

    Science.gov (United States)

    Two experiments were conducted to evaluate the use of a washed rumen technique as an alternative approach for determining fasting HP in cattle. In Exp. 1, 8 Holstein steers (322±30 kg) were adapted to a cubed alfalfa-based diet (1.5xNEm) for 10 d. After which steers were placed into individual hea...

  13. Studies for determining drain solid flow in bed silt, using radioisotope techniques

    International Nuclear Information System (INIS)

    Sanchez, W.

    1976-01-01

    A process for measuring solid flow in silt bed using isotopic technique is studied. Comparative studies for initial movement of grinded glass grains and sand grains is done. The development for determining the minimum mass of radioative grains of sand, used for flow evaluation is also studied. Further experiments in the field of reference confirm technological conditions for the method [pt

  14. A review of analytical techniques for the determination of carbon-14 in environmental samples

    International Nuclear Information System (INIS)

    Milton, G.M.; Brown, R.M.

    1993-11-01

    This report contains a brief summary of analytical techniques commonly used for the determination of radiocarbon in a variety of environmental samples. Details of the applicable procedures developed and tested in the Environmental Research Branch at Chalk River Laboratories are appended

  15. A note on determination of the diffuse-field sensitivity of microphones using the reciprocity technique

    DEFF Research Database (Denmark)

    Barrera Figueroa, Salvador; Jacobsen, Finn

    2008-01-01

    angles of incidence but also on the accuracy of the frequency response at normal incidence. By contrast, this paper is concerned with determining the absolute diffuse-field response of a microphone using the reciprocity technique. To examine this possibility, a reciprocity calibration setup is used...

  16. Separation Techniques for Uranium and Plutonium at Trace Levels for the Thermal Ionization Mass Spectrometric Determination

    International Nuclear Information System (INIS)

    Suh, M. Y.; Han, S. H.; Kim, J. G.; Park, Y. J.; Kim, W. H.

    2005-12-01

    This report describes the state of the art and the progress of the chemical separation and purification techniques required for the thermal ionization mass spectrometric determination of uranium and plutonium in environmental samples at trace or ultratrace levels. Various techniques, such as precipitation, solvent extraction, extraction chromatography, and ion exchange chromatography, for separation of uranium and plutonium were evaluated. Sample preparation methods and dissolution techniques for environmental samples were also discussed. Especially, both extraction chromatographic and anion exchange chromatographic procedures for uranium and plutonium in environmental samples, such as soil, sediment, plant, seawater, urine, and bone ash were reviewed in detail in order to propose some suitable methods for the separation and purification of uranium and plutonium from the safeguards environmental or swipe samples. A survey of the IAEA strengthened safeguards system, the clean room facility of IAEA's NWAL(Network of Analytical Laboratories), and the analytical techniques for safeguards environmental samples was also discussed here

  17. Separation Techniques for Uranium and Plutonium at Trace Levels for the Thermal Ionization Mass Spectrometric Determination

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Han, S. H.; Kim, J. G.; Park, Y. J.; Kim, W. H

    2005-12-15

    This report describes the state of the art and the progress of the chemical separation and purification techniques required for the thermal ionization mass spectrometric determination of uranium and plutonium in environmental samples at trace or ultratrace levels. Various techniques, such as precipitation, solvent extraction, extraction chromatography, and ion exchange chromatography, for separation of uranium and plutonium were evaluated. Sample preparation methods and dissolution techniques for environmental samples were also discussed. Especially, both extraction chromatographic and anion exchange chromatographic procedures for uranium and plutonium in environmental samples, such as soil, sediment, plant, seawater, urine, and bone ash were reviewed in detail in order to propose some suitable methods for the separation and purification of uranium and plutonium from the safeguards environmental or swipe samples. A survey of the IAEA strengthened safeguards system, the clean room facility of IAEA's NWAL(Network of Analytical Laboratories), and the analytical techniques for safeguards environmental samples was also discussed here.

  18. 222Rn Determination In Drinking Waters - RAD7 And LSC Technique Comparison

    International Nuclear Information System (INIS)

    Todorovic, N.; Stojkovic, I.; Nikolov, J.; Tenjovic, B.

    2015-01-01

    A procedure for the determination of 222Rn in environmental water samples using liquid scintillation counting (LSC) was applied and optimized. For radon determination in drinking water from groundwater and surface water sources by LSC, the EPA Method 913.0 was used. A minimum detectable activity of 0.029 Bq L-1 in a 20 mL glass vial (10 mL water sample mixed with 10 mL of liquid scintillation cocktail) has been achieved during 300 minutes of measurement time. The procedure was compared with RAD7 radon detector measurements. Factors that affect the measurement accuracy and precision of RAD7 radon detector are the sampling technique, sample concentration, sample size, counting time, temperature, relative humidity and background effects. The minimal detectable activity (MDA) for RAD7 technique was found to be 0.1 Bq/L. From obtained results of 222Rn measurements in 15 water samples with different 222Rn activities, correlation between the two techniques applied for measurements of 222Rn in water samples (A less than 400 Bq/L) was determined. There is reasonable agreement (within statistical uncertainties) between the various techniques in most cases, while disagreements most likely come from systematic uncertainties associated with sampling procedures. Discrepancy in determined activities between the two techniques becomes more evident with increased 222Rn activities in water. LSC technique gives in general higher activity concentrations for about 30 percent than RAD7 spectrometer. The interpretation of shown results could be that RAD7 is not properly calibrated for higher activities, since USA reference level of 222Rn concentrations in water is only 11.1 Bq/L (US EPA, Proposed Radon in Drinking Water Regulation). (author).

  19. Simulation of thermal radiation, illustrated by the Bridgman casting process for directional solidification of turbine blades; Simulation von Waermestrahlung am Beispiel des Bridgman-Verfahrens zur gerichteten Erstarrung von Turbinenschaufeln

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, N

    1996-12-31

    Directionally solidified turbine blades for high-temperature applications today are commonly produced by the Bridgman casting process. The production of a newly constructed turbine blade requires a number of costly and time-consuming casting experiments. The author develops a numerical simulation model based on the finite element method and net radiation method for low-cost and short-term simulation and optimisation of the casting experiments. Several different numerical methods for calculating thermal radiation are compared (radiosity, ray tracing and the finite difference method), and the simulation results are presented for several exemplry turbine blades. Further, an optimisation strategy for improving the quality of the turbine blade casting process is presented. (orig.). 65 figs., 8 tabs. [Deutsch] Gerichtet erstarrte Turbinenschaufeln mit hoher Einsatztemperatur werden nach dem heutigen Stand der Technik nach dem Bridgman-Verfahren gegossen. Die Herstellung einer neu konstruierten Turbinenschaufel verlangt eine Reihe von kosten- und zeitaufwendigen Giessexperimenten. In der vorliegenden Arbeit wird ein numerisches Simulationsmodell auf Basis der Finiten Elemente Methode und Net Radiation Methode entwickelt, mit dem sich kostenguenstig und in kurzen Zeitraeumen die Giessversuche simulieren und optimieren lassen. Die Arbeit vergleicht verschiedene numerische Loesungsverfahren fuer die Waermestrahlung (Radiosity, Ray Tracing und Finite Differenzen Verfahren) und stellt am Beispiel einiger Turbinenschaufeln die Simulationsergebnisse dar. Weiterhin wird eine Optimierungsstrategie fuer Verbesserung der Gussqualitaet von Turbinenschaufeln vorgestellt. (orig.)

  20. Nuclear assay of coal. Volume 4. Moisture determination in coal: survey of electromagnetic techniques. Final report

    International Nuclear Information System (INIS)

    Bevan, R.; Luckie, P.; Gozani, T.; Brown, D.R.; Bozorgmanesh, H.; Elias, E.

    1979-01-01

    This survey consists of two basic parts. The first consists of a survey of various non-nuclear moisture determination techniques. Three techniques are identified as promising for eventual on-line application with coal; these are the capacitance, microwave attenuation, and nuclear magnetic resonance (NMR) techniques. The second part is devoted to an in-depth analysis of these three techniques and the current extent to which they have been applied to coal. With a given coal type, accuracies of +- 1% absolute in moisture content are achievable with all three techniques. The accuracy of the two electromagnetic techniques has been demonstrated in the laboratory and on-line in coal burning plants, whereas only small samples have been analyzed with NMR. The current shortcoming of the simple electromagnetic techniques is the sensitivity of calibrations to physical parameters and coal type. NMR is currently limited by small sample sizes and non-rugged design. These findings are summarized and a list of manufacturers of moisture analyzers is given in the Appendix

  1. Determination of trace elements in plant samples using XRF, PIXE and ICP-OES techniques

    International Nuclear Information System (INIS)

    Ahmed, Hassan Elzain Hassan

    2014-07-01

    The purpose of this study is to determine trace element concentration (Ca, Cu, Cr, K,Fe, Mn,Sr, and Za) in some sudanese wild plants namely, Ziziphus Abyssinica and Grewia Tenax. X-ray fluorescence ( X RF), particle-induced x-ray emission ( PIXE) and inductively coupled plasma-optical emission spectroscopy (ICP-OES) techniques were used for element determination. A series of plants standard references materials were used to check the reliability of the different employed techniques as well as to estimate possible factors for correcting the concentration of some elements that deviated significantly from their actual concentration. The results showed that, X RF, PIXE and ICP-OES are equally competitive methods for measuring Ca,K, Fe, Sr and Zn elements. Unlikely to ICP-OES seems to be superior techniques tend to be appropriate methods for Cu determination in plant samples however, for Mn element PIXE and ICP-OES are advisable techniques for measuring this element rather than X RF method. On the other hand, ICP-OES seems to be the superior techniques over PIXE and X RF methods for Cr and Ni determination in plant samples. The effect of geographical location on trace elements concentration in plants has been examined through determination of element in different species of Grewia Tenax than collected from different location. Most of measured elements showed similarity indicating there is no significant impact of locations on the difference of element contents. In addition, two plants with different genetic families namely, Ziziphus Spina Christi and Ziziphus Abyssinica were collected from the same location and screened for their trace element content. It was found that there were no difference between the two plants for Ca, K, Cu, Fe, and Sr element. However, significant variations were observed for Mn and Zn concentrations implying the possibility of using of those two elements for plant taxonomy purposes.(Author)

  2. Review of tomography technique for 3-dimensional fission product distribution determination in irradiated fuel

    Energy Technology Data Exchange (ETDEWEB)

    Pakr, D G; Hong, K P; Joo, Y S; Lee, H K

    2006-04-15

    Tomography algorithm is reviewed in order to determine radial 2-dimensional fission product distribution of irradiated fuel rod and to reconstruct it's image using computer. Main contents are Radon transformation, Fourier central slice theorem, inverse Fourier transform, accompanied FBP(Filtered Back Projection) and BPB(Back Projection Filtering). In addition, another tomography reconstruction algorithm, namely, ART(Algebraic Reconstruction Technique) is reviewed briefly. According to reviewed results, we devise equipment for determining of 2-dimensional distribution of irradiated nuclear fuel using existing gamma scanning apparatus. On results of review, It is necessary to develop computer program of reconstruction algorithm for determining of object function and image reconstruction.

  3. Review of tomography technique for 3-dimensional fission product distribution determination in irradiated fuel

    International Nuclear Information System (INIS)

    Pakr, D. G.; Hong, K. P.; Joo, Y. S.; Lee, H. K.

    2006-04-01

    Tomography algorithm is reviewed in order to determine radial 2-dimensional fission product distribution of irradiated fuel rod and to reconstruct it's image using computer. Main contents are Radon transformation, Fourier central slice theorem, inverse Fourier transform, accompanied FBP(Filtered Back Projection) and BPB(Back Projection Filtering). In addition, another tomography reconstruction algorithm, namely, ART(Algebraic Reconstruction Technique) is reviewed briefly. According to reviewed results, we devise equipment for determining of 2-dimensional distribution of irradiated nuclear fuel using existing gamma scanning apparatus. On results of review, It is necessary to develop computer program of reconstruction algorithm for determining of object function and image reconstruction

  4. Determination of the uranium concentration in apatite by the fission - track registration technique

    International Nuclear Information System (INIS)

    D'Oliveira Cardoso, D.

    1983-01-01

    The feasibility of using the fission-track registration technique to determine the uranium content in the phosphate rock beneficiation steps carried on by CompanhiA Arafertil, Araxa, Minas Gerais, Brazil is studied. This determination is of considerable interest to the environmental control of the Arafertil installations as well as of its surroundings or of the areas where these products will be used. The so called wet method was adopted and a 10 μm polycarbonate foil, fabricated by Bayer under the trade name Makrofol KG was used as detector. From the calibration curve obtained, it was possible to determine uranium contents in sample solutions ranging from 21 to 212 μg U/1 with an accuracy of 8 to 14.7%, respectively. The results obtained demonstrated that the technique used is appropriate to the purposes previously aimed at. (Author) [pt

  5. The determination of pesticide residues in local vegetables by means of neutron activation technique

    International Nuclear Information System (INIS)

    Mongkolphantha, S.; Karasuddhi, P.; Yamkate, P.; Serichareonsatit, N.

    1975-01-01

    Analytical methods based on neutron activation have been developed for studying pesticides residues of bromine, arsenic and mercury in local vegetables and fruits. The concentration of bromine, arsenic and mercury in samples are enriched prior to neutron irradiations by a technique of dry-ashing and freeze-drying for the determination of arsenic, bromine and mercury respectively. The element bromine is determined instrumentally while arsenic and mercury are determined destructively using a distillation technique. The limit of detection under the conditions used for bromine, arsenic and mercury as obtained are 0.01, 0.001 and 0.0001 microgram respectively. A total of 45 varieties of vegetables and 20 varieties of fruits are analyzed. The results of the investigation and the concentration range in part per million of bromine, arsenic and mercury are also presented

  6. Advanced gamma spectrum processing technique applied to the analysis of scattering spectra for determining material thickness

    International Nuclear Information System (INIS)

    Hoang Duc Tam; VNUHCM-University of Science, Ho Chi Minh City; Huynh Dinh Chuong; Tran Thien Thanh; Vo Hoang Nguyen; Hoang Thi Kieu Trang; Chau Van Tao

    2015-01-01

    In this work, an advanced gamma spectrum processing technique is applied to analyze experimental scattering spectra for determining the thickness of C45 heat-resistant steel plates. The single scattering peak of scattering spectra is taken as an advantage to measure the intensity of single scattering photons. Based on these results, the thickness of steel plates is determined with a maximum deviation of real thickness and measured thickness of about 4 %. Monte Carlo simulation using MCNP5 code is also performed to cross check the results, which yields a maximum deviation of 2 %. These results strongly confirm the capability of this technique in analyzing gamma scattering spectra, which is a simple, effective and convenient method for determining material thickness. (author)

  7. Determination of the aerosol filters efficiency by means of the tracer techniques

    International Nuclear Information System (INIS)

    Hirling, J.

    1978-01-01

    Estimation of the nonradioactive methods of filters efficiency determination and tracer techniques are given. The methods are stated and discriptions of the instrumentation for estimation of the filters efficiency are given, in particular: methodology of production of the radioactive synthetic test-aerosols by means of the disperse and steamcondensation aerosol generators; the radio isotope method of the aerosol filters investigations; the methodology of filtartion efficiency determination. The results are given of the radioisotope investigations of filters; properties of the artificial radioactive test-aerosols; characteristics of filters, determined by the tracer techniques. Curves are given for the filtration efficiency of the viscose filtering nozzles of different density depending on the filters load. (I.T.) [ru

  8. Determination of the uranium concentration in soil solutions by the fission track registration technique

    International Nuclear Information System (INIS)

    Fernandes, G.P.

    1980-02-01

    The fission tracks registration technique was used to determine the uranium concentration in soil solutions. The Makrofol KG, a synthetic plastic manufactured by Bayer, was used as a detector and the wet method was applied. From the calibration curves obtained, it was possible to determine uranium concentrations in soil solutions, from 90 to 320 μg U/l, with an error between 9.4% and 4.0%, respectively. The method was applied to a few soil samples from Pocos de Caldas, Minas Gerais in Brazil. The uranium concentrations in the sample and residues were also determined by other methods to compare the results obtained; only one sample showed deviation from the results obtained by the fission tracks method. And this discrepancy was explained in a reasonable way. It was shown that the fission tracks technique can be used with sucess for application in soil solutions. (Author) [pt

  9. Comparative study between the PIXE technique and neutron activation analysis for Zinc determination

    International Nuclear Information System (INIS)

    Cruvinel, Paulo Estevao; Crestana, Silvio; Artaxo Netto, Paulo Eduardo

    1997-01-01

    This work presents a comparative study between the PIXE, proton beams and neutron activation analysis (NAA) techniques, for determination of total zinc concentration. Particularly, soil samples from the Pindorama, Instituto Agronomico de Campinas, Sao Paulo State, Brazil, experimental station have been analysed and measuring the zinc contents in μg/g. The results presented good correlation between the mentioned techniques. The PIXE and NAA analyses have been carried out by using the series S, 2.4 MeV proton beams Pelletron accelerator and the IPEN/CNEN-IEA-R1 reactor, both installed at the Sao Paulo - Brazil university

  10. Current status on techniques for determining paleo-temperature using geothermometer

    International Nuclear Information System (INIS)

    Kanazawa, Sunao; Oikawa, Teruki; Umeda, Koji; Tomiyama, Shingo

    2005-01-01

    Development of the research technologies for geotectonic events has been carried out to evaluate the long-term stability of geological environment. In terms of the effects of geothermal activity, it is necessary to estimate the geothermal regime and thermal history on any given site. This paper describes the current status on techniques for determining paleo-temperature using geothermometer, and presents a concept of the systematic research techniques. The application of geothermometer, especially thermochronology, has been effective in the studies on the cooling history of geological body and the paleo-geothermal structure at depth. (author)

  11. Trace and essential elements determination in baby formulas milk by INAA and k0-INAA techniques

    International Nuclear Information System (INIS)

    Lylia Hamidatou; Hocine Slamene; Tarik Akhal; Alaa Boulegane

    2014-01-01

    As a part of the food analysis program executed at Es-Salam research reactor by neutron activation analysis laboratory, the concentration of As, Ba, Br, Ca, Fe, K, La, Rb and Zn in baby formulas milk have been determined by using INAA and k 0 -NAA techniques. It was found that the concentration of all elements obtained by both techniques was relatively identical for the three brands of the 0-6 and 6-12 months of analyzed samples. In addition, the analytical results have been compared with those given by producers. (author)

  12. Calculation and experimental technique of determination of rolling procedure for cold-rolling tube mills

    International Nuclear Information System (INIS)

    Igoshin, V.F.; Aleshin, V.A.; Khoroshikh, Yu.G.; Bogatov, A.A.; Mizhiritskij, O.I.

    1983-01-01

    Calculation and experimental technique of determination of tube cold rolling procedure has been developed. Rolling procedure based on the usage of regression equation epsilon=1.24 psi, where psi is the relative reduction of area, delta-permissible reduction during rolling, has been tested on 08Kh18N10T steel. The effect of tube geometry, tool calibration parameters, lubrication conditions etc. on metal deformability in taking into account experimentally. The use of the technique proposed has allowed to shorten the time of mastering of the production of tubes from different steels

  13. Optimum conditions for the determination of ionization potentials, appearance potentials and fine structure in ionization efficiency curves using edd technique

    International Nuclear Information System (INIS)

    Selim, Ezzat T.; El-Kholy, S.B.; Zahran, Nagwa F.

    1978-01-01

    The optimum conditions for determining ionization potentials as well as fine structure in electron impact ionization efficiency curves are studied using energy distribution difference technique. Applying these conditions to Ar + , Kr + , CO + 2 and N + from N 2 , very good agreement is obtained when compared with results determined by other techniques including UV spectroscopy. The merits and limitation of the technique are also discussed

  14. The scratch test - Different critical load determination techniques. [adhesive strength of thin hard coatings

    Science.gov (United States)

    Sekler, J.; Hintermann, H. E.; Steinmann, P. A.

    1988-01-01

    Different critical load determination techniques such as microscopy, acoustic emission, normal, tangential, and lateral forces used for scratch test evaluation of complex or multilayer coatings are investigated. The applicability of the scratch test to newly developed coating techniques, systems, and applications is discussed. Among the methods based on the use of a physical measurement, acoustic emission detection is the most effective. The dynamics ratio between the signals below and above the critical load for the acoustic emission (much greater than 100) is well above that obtained with the normal, tangential, and lateral forces. The present commercial instruments are limited in load application performance. A scratch tester able to apply accurate loads as low as 0.01 N would probably overcome most of the actual limitations and would be expected to extend the scratch testing technique to different application fields such as optics and microelectronics.

  15. Nuclear-physical techniques for determination of boron distribution in pure materials

    International Nuclear Information System (INIS)

    Kadirova, M.; Jumaev, N.; Simakhin, Yu.F.; Idrisov, Kh.; Usmanova, M.M.

    2001-01-01

    To study deep boron diffusion in the complex silicon structures, consisting of interchange boron doping layers of mono- and polycrystalline silicon, separated by oxide films a technique of sidelong section by using Solid State Nuclear Track Detector (SSNTD) has been elaborated. The boron distribution determination technique is based on the detection of alpha particles from the 10B(n, )7Li reaction with cellulose nitrate film. The etched track registering cellulose nitrate film show the structure image magnified 1/sin fold. Boron concentration defined by density of the etched pits appearing on the film surface. An optical microscope analysis of the sample track-mapping image is realized by examination with closely spaced ( l < x/sin ) and largely spaced ( l x/sin ) movements. All these elaborated techniques can be used to investigate other solid matrix

  16. Development of the charcoal adsorption technique for determination of radon content in natural gas

    International Nuclear Information System (INIS)

    Paewpanchon, P.; Chanyotha, S.

    2017-01-01

    A technique for the determination of the radon concentration in natural gas using charcoal adsorption has been developed to study the effects of parameters that influence the adsorption efficiency of radon onto activated charcoal. Several sets of experiments were conducted both in the laboratory and in an actual natural gas field for comparison. The results show that the adsorption capability of radon onto activated charcoal varies inversely with temperature, hydrocarbon concentration and the humidity contained within the natural gas. A technique utilizing dry ice as a coolant was found to be the most effective for trapping radon in natural gas samples at the production site. A desiccant can be used to remove moisture from the sampling gas. The technique described here increases the adsorption efficiency of activated charcoal by 10-20% compared to our previous study. (authors)

  17. DEVELOPMENT OF THE CHARCOAL ADSORPTION TECHNIQUE FOR DETERMINATION OF RADON CONTENT IN NATURAL GAS.

    Science.gov (United States)

    Paewpanchon, P; Chanyotha, S

    2017-11-01

    A technique for the determination of the radon concentration in natural gas using charcoal adsorption has been developed to study the effects of parameters that influence the adsorption efficiency of radon onto activated charcoal. Several sets of experiments were conducted both in the laboratory and in an actual natural gas field for comparison. The results show that the adsorption capability of radon onto activated charcoal varies inversely with temperature, hydrocarbon concentration and the humidity contained within the natural gas. A technique utilizing dry ice as a coolant was found to be the most effective for trapping radon in natural gas samples at the production site. A desiccant can be used to remove moisture from the sampling gas. The technique described here increases the adsorption efficiency of activated charcoal by 10-20% compared to our previous study. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Validation of a residue method to determine pesticide residues in cucumber by using nuclear techniques

    International Nuclear Information System (INIS)

    Baysoyu, D.; Tiryaki, O.; Secer, E.; Aydin, G.

    2009-01-01

    In this study, a multi-residue method using ethyl acetate for extraction and gel permeation chromatography for clean-up was validated to determine chlorpyrifos, malathion and dichlorvos in cucumber by gas chromatography. For this purpose, homogenized cucumber samples were fortified with pesticides at 0.02 0.2, 0.8 and 1 mg/kg levels. The efficiency and repeatability of the method in extraction and cleanup steps were performed using 1 4C-carbaryl by radioisotope tracer technique. 1 4C-carbaryl recoveries after the extraction and cleanup steps were between 92.63-111.73 % with a repeatability of 4.85% (CV) and 74.83-102.22 % with a repeatability of 7.19% (CV), respectively. The homogeneity of analytical samples and the stability of pesticides during homogenization were determined using radio tracer technique and chromatographic methods, respectively.

  19. A novel technique to determine concentration-dependent solvent dispersion in Vapex

    Energy Technology Data Exchange (ETDEWEB)

    Abukhalifeh, H.; Lohi, A.; Upreti, S. R. [Department of Chemical Engineering, Ryerson University, 350 Victoria Street, Toronto, Ontario, M5B 2K3 (Canada)

    2009-07-01

    Vapex (vapor extraction of heavy oil and bitumen) is a promising recovery technology because it consumes low energy, and is very environmentally-friendly. The dispersion of solvents into heavy oil and bitumen is a crucial transport property governing Vapex. The accurate determination of solvent dispersion in Vapex is essential to effectively predict the amount and time scale of oil recovery as well to optimize the field operations. In this work, a novel technique is developed to experimentally determine the concentration-dependent dispersion coefficient of a solvent in Vapex process. The principles of variational calculus are utilized in conjunction with a mass transfer model of the experimental Vapex process. A computational algorithm is developed to optimally compute solvent dispersion as a function of its concentration in heavy oil. The developed technique is applied to Vapex utilizing propane as a solvent. The results show that dispersion of propane is a unimodal function of its concentration in bitumen. (author)

  20. A Novel Technique to Determine Concentration-Dependent Solvent Dispersion in Vapex

    Directory of Open Access Journals (Sweden)

    Hadil Abukhalifeh

    2009-10-01

    Full Text Available Vapex (vapor extraction of heavy oil and bitumen is a promising recovery technology because it consumes low energy, and is very environmentally-friendly. The dispersion of solvents into heavy oil and bitumen is a crucial transport property governing Vapex. The accurate determination of solvent dispersion in Vapex is essential to effectively predict the amount and time scale of oil recovery as well to optimize the field operations. In this work, a novel technique is developed to experimentally determine the concentration-dependent dispersion coefficient of a solvent in Vapex process. The principles of variational calculus are utilized in conjunction with a mass transfer model of the experimental Vapex process. A computational algorithm is developed to optimally compute solvent dispersion as a function of its concentration in heavy oil. The developed technique is applied to Vapex utilizing propane as a solvent. The results show that dispersion of propane is a unimodal function of its concentration in bitumen.

  1. A Compton scattering technique to determine wood density and locating defects in it

    International Nuclear Information System (INIS)

    Tondon, Akash; Sandhu, B. S.; Singh, Bhajan; Singh, Mohinder

    2015-01-01

    A Compton scattering technique is presented to determine density and void location in the given wooden samples. The technique uses a well collimated gamma ray beam from 137 Cs along with the NaI(Tl) scintillation detector. First, a linear relationship is established between Compton scattered intensity and known density of chemical compounds, and then density of the wood is determined from this linear relation. In another experiment, the ability of penetration of gamma rays is explored to detect voids in wooden (low Z) sample. The sudden reduction in the Compton scattered intensities agrees well with the position and size of voids in the wooden sample. It is concluded that wood density and the voids of size ∼ 4 mm and more can be detected easily by this method

  2. A Photometric Technique for Determining Fluid Concentration using Consumer-Grade Hardware

    Science.gov (United States)

    Leslie, F.; Ramachandran, N.

    1999-01-01

    In support of a separate study to produce an exponential concentration gradient in a magnetic fluid, a noninvasive technique for determining, species concentration from off-the-shelf hardware has been developed. The approach uses a backlighted fluid test cell photographed with a commercial digital camcorder. Because the light extinction coefficient is wavelength dependent, tests were conducted to determine the best filter color to use, although some guidance was also provided using an absorption spectrophotometer. With the appropriate filter in place, the provide attenuation of the light passing, through the test cell was captured by the camcorder. The digital image was analyzed for intensity using, software from Scion Image Corp. downloaded from the Internet. The analysis provides a two-dimensional array of concentration with an average error of 0.0095 ml/ml. This technique is superior to invasive techniques, which require extraction of a sample that disturbs the concentration distribution in the test cell. Refinements of this technique using a true monochromatic laser light Source are also discussed.

  3. In-situ temperature field measurements and direct observation of crystal/melt at vertical Bridgman growth of lead chloride under stationary and dynamic arrangement

    Czech Academy of Sciences Publication Activity Database

    Král, Robert; Nitsch, Karel

    2015-01-01

    Roč. 427, Oct (2015), 7-15 ISSN 0022-0248 R&D Projects: GA MŠk(CZ) LH14266 Institutional support: RVO:68378271 Keywords : single crystal growth * temperature field measurements * crystal/melt interface * lead chloride * vertical Bridgman method Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.462, year: 2015

  4. Technique for determination of elastic limit of micron band-thick amorphous

    International Nuclear Information System (INIS)

    Zakharov, E.K.; Pol'dyaeva, G.P.; Tret'yakov, B.N.

    1984-01-01

    A method is suggested to determine the elastic limit of micron-thick amorphous band under bending. The elastic limit is determined by bending an amorphous band sample around a series of cylindrical mandrels of gradually decreasing radius. Experimental data on measuring the elastic limit of some amorphous iron base alloys according to the suggested technique are presented. The elastic limit of amorphous alloys is shown to lie in the 3140-4110 MPa range depending on chemical composition, which is about 2-2.5 times higher as compared to high-strength crystal alloys

  5. Determination in soils of soluble uranium fraction in acid medium by fission tracks registration techniques

    International Nuclear Information System (INIS)

    Fernandes, G.P.

    1980-01-01

    The fission tracks registration technique was used to determine the concentration of uranium in soil solutions. The Makrofol KG, a synthetic plastic manufactured by Bayer, was used as a detector and the wet method was applied. The method was applied to a few samples of soils from Pocos de Caldas, Minas Gerais in Brazil. The concentrations of uranium in the samples and residues were also determined by other methods to compare the results obtained; only one sample showed deviation among the results obtained by the fission tracks method. (author)

  6. The use of a single technique for the separation and determination of actinides in biological materials

    International Nuclear Information System (INIS)

    Camera, V.; Giubileo.

    1975-01-01

    For the radiotoxicological survey of workers exposed to different types of alpha-emitting contaminants, a procedure was developed which permits the estimate of Th, Pa, U, Np, Pu, Am and Cm in biological samples with a single technique. The radionuclides are extracted on a column by tri-n-octylphosphine oxide and separated by elution at different pH values. Afterwards, the quantitative determinations are done by physical methods (alpha counting or spectrometry). In the case of an accident it is possible to use a simplification of the procedure (extraction in a beaker) for checks. A procedure for the rapid determination of actinides in faeces and in nasal secretions is described

  7. Autoradiographic techniques to determine noble metal distribution in automotive catalyst substrates

    International Nuclear Information System (INIS)

    Lange, W.H.

    1976-01-01

    The distribution of noble metals in the ceramic substrates of automotive catalytic converter systems is important to the functional characteristics of the systems. A radiotracer technique involving microtomy of bead substrate samples and autoradiography using the resultant thin sections was developed to produce detailed images of the metal distributions. The method is particularly valuable to determine the distribution of one metal in the presence of another to aid in the development of more efficient systems

  8. Influence of the tool construction on determination of iron-grade in parameter P-techniques

    International Nuclear Information System (INIS)

    Charbucinski, J.

    1975-01-01

    The results of laboratory tests for utilization of parameter P-technique in gamma-gamma method for the purpose of determination of iron content in an ore have been presented. Measurements were performed in the 4π geometry. The various dependences of the tool response on physical-technical parameters of the tool and the borehole-stratum system have been examined. Optimum construction of the borehole tool has been recommended. (author)

  9. Determining the metallicity of the solar envelope using seismic inversion techniques

    Science.gov (United States)

    Buldgen, G.; Salmon, S. J. A. J.; Noels, A.; Scuflaire, R.; Dupret, M. A.; Reese, D. R.

    2017-11-01

    The solar metallicity issue is a long-lasting problem of astrophysics, impacting multiple fields and still subject to debate and uncertainties. While spectroscopy has mostly been used to determine the solar heavy elements abundance, helioseismologists attempted providing a seismic determination of the metallicity in the solar convective envelope. However, the puzzle remains since two independent groups provided two radically different values for this crucial astrophysical parameter. We aim at providing an independent seismic measurement of the solar metallicity in the convective envelope. Our main goal is to help provide new information to break the current stalemate amongst seismic determinations of the solar heavy element abundance. We start by presenting the kernels, the inversion technique and the target function of the inversion we have developed. We then test our approach in multiple hare-and-hounds exercises to assess its reliability and accuracy. We then apply our technique to solar data using calibrated solar models and determine an interval of seismic measurements for the solar metallicity. We show that our inversion can indeed be used to estimate the solar metallicity thanks to our hare-and-hounds exercises. However, we also show that further dependencies in the physical ingredients of solar models lead to a low accuracy. Nevertheless, using various physical ingredients for our solar models, we determine metallicity values between 0.008 and 0.014.

  10. The development of techniques for determining the residual life time prediction on NPP equipment

    International Nuclear Information System (INIS)

    Antonov, Alexander V.; Dagaev, Alexander V.; Volnikov, Ivan S.

    1999-01-01

    The problem of determining the residual life prediction of NPP equipment is presently highly pressing. NPP residual life resources are 30 years, but for particular equipment it is much less. Thus, residual life resource for equipment of control and protection system of NPP unit is 5-10 years. The NPP equipment is expensive and its replacing requires much expense. Hence an urgent problem is to study residual life resources of equipment on the basis of statistic information obtained during operation. Deterministic approach of determining residual life resources for particular equipment is widely known in the literature. Physical and statistical models are also being developed for determining the residual life, e.g. the model (loading-bearing capability). The present work offers the techniques of the residual life determination reasoning from statistic information of functioning objects in the process of operation. To put the techniques into effect it is necessary to have information about the time of operation of a group of objects of the same type, the number of failures; it is desirable to know failure operating time, order of the object replacement and the reason which caused the replacement (failure or planned preventive maintenance). Metrics is based on studying the parameters for the series of failures resulted from real statistic data. Then we can proceed to distribution density of the failure working time. For this purpose the Voltarra's equation of the second order is solved f(t) = ω(t) + ∫ 0 t f(t - τ)ω(τ)dτ. Since statistics of data sampling related to failure is small due to difficulties in solution of Voltaire's equation, the authors offer moderate method of solution for the above equation. After distribution density of the failure working time is determined the calculation of equipment residual life is made by the following formula: T τ (t) 1/P(τ)∫ 0 ∞ P(t)dt. The proposed techniques are realised as the software. In the course of working

  11. Determination of metals in air samples using X-Ray fluorescence associated the APDC preconcentration technique

    Energy Technology Data Exchange (ETDEWEB)

    Nardes, Raysa C.; Santos, Ramon S.; Sanches, Francis A.C.R.A.; Gama Filho, Hamilton S.; Oliveira, Davi F.; Anjos, Marcelino J., E-mail: rc.nardes@gmail.com, E-mail: ramonziosp@yahoo.com.br, E-mail: francissanches@gmail.com, E-mail: hamiltongamafilho@hotmail.com, E-mail: davi.oliveira@uerj.br, E-mail: marcelin@uerj.br [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Instituto de Fisica. Departamento de Fisica Aplicada e Termodinamica

    2015-07-01

    Air pollution has become one of the leading quality degradation factors of life for people in large urban centers. Studies indicate that the suspended particulate matter in the atmosphere is directly associated with risks to public health, in addition, it can cause damage to fauna, flora and public / cultural patrimonies. The inhalable particulate materials can cause the emergence and / or worsening of chronic diseases related to respiratory system and other diseases, such as reduced physical strength. In this study, we propose a new method to measure the concentration of total suspended particulate matter (TSP) in the air using an impinger as an air cleaning apparatus, preconcentration with APDC and Total Reflection X-ray Fluorescence technique (TXRF) to analyze the heavy metals present in the air. The samples were collected from five random points in the city of Rio de Janeiro/Brazil. Analyses of TXRF were performed at the Brazilian Synchrotron Light Laboratory (LNLS). The technique proved viable because it was able to detect five important metallic elements to environmental studies: Cr, Fe, Ni, Cu and Zn. This technique presented substantial efficiency in determining the elementary concentration of air pollutants, in addition to low cost. It can be concluded that the metals analysis technique in air samples using an impinger as sample collection instrument associated with a complexing agent (APDC) was viable because it is a low-cost technique, moreover, it was possible the detection of five important metal elements in environmental studies associated with industrial emissions and urban traffic. (author)

  12. Determining oxygen relaxations at an interface: A comparative study between transmission electron microscopy techniques.

    Science.gov (United States)

    Gauquelin, N; van den Bos, K H W; Béché, A; Krause, F F; Lobato, I; Lazar, S; Rosenauer, A; Van Aert, S; Verbeeck, J

    2017-10-01

    Nowadays, aberration corrected transmission electron microscopy (TEM) is a popular method to characterise nanomaterials at the atomic scale. Here, atomically resolved images of nanomaterials are acquired, where the contrast depends on the illumination, imaging and detector conditions of the microscope. Visualization of light elements is possible when using low angle annular dark field (LAADF) STEM, annular bright field (ABF) STEM, integrated differential phase contrast (iDPC) STEM, negative spherical aberration imaging (NCSI) and imaging STEM (ISTEM). In this work, images of a NdGaO 3 -La 0.67 Sr 0.33 MnO 3 (NGO-LSMO) interface are quantitatively evaluated by using statistical parameter estimation theory. For imaging light elements, all techniques are providing reliable results, while the techniques based on interference contrast, NCSI and ISTEM, are less robust in terms of accuracy for extracting heavy column locations. In term of precision, sample drift and scan distortions mainly limits the STEM based techniques as compared to NCSI. Post processing techniques can, however, partially compensate for this. In order to provide an outlook to the future, simulated images of NGO, in which the unavoidable presence of Poisson noise is taken into account, are used to determine the ultimate precision. In this future counting noise limited scenario, NCSI and ISTEM imaging will provide more precise values as compared to the other techniques, which can be related to the mechanisms behind the image recording. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Determination of metals in air samples using X-Ray fluorescence associated the APDC preconcentration technique

    International Nuclear Information System (INIS)

    Nardes, Raysa C.; Santos, Ramon S.; Sanches, Francis A.C.R.A.; Gama Filho, Hamilton S.; Oliveira, Davi F.; Anjos, Marcelino J.

    2015-01-01

    Air pollution has become one of the leading quality degradation factors of life for people in large urban centers. Studies indicate that the suspended particulate matter in the atmosphere is directly associated with risks to public health, in addition, it can cause damage to fauna, flora and public / cultural patrimonies. The inhalable particulate materials can cause the emergence and / or worsening of chronic diseases related to respiratory system and other diseases, such as reduced physical strength. In this study, we propose a new method to measure the concentration of total suspended particulate matter (TSP) in the air using an impinger as an air cleaning apparatus, preconcentration with APDC and Total Reflection X-ray Fluorescence technique (TXRF) to analyze the heavy metals present in the air. The samples were collected from five random points in the city of Rio de Janeiro/Brazil. Analyses of TXRF were performed at the Brazilian Synchrotron Light Laboratory (LNLS). The technique proved viable because it was able to detect five important metallic elements to environmental studies: Cr, Fe, Ni, Cu and Zn. This technique presented substantial efficiency in determining the elementary concentration of air pollutants, in addition to low cost. It can be concluded that the metals analysis technique in air samples using an impinger as sample collection instrument associated with a complexing agent (APDC) was viable because it is a low-cost technique, moreover, it was possible the detection of five important metal elements in environmental studies associated with industrial emissions and urban traffic. (author)

  14. Crystallographic Orientation Determination of Hexagonal Structure Crystals by Laser Ultrasonic Technique

    International Nuclear Information System (INIS)

    Li, W; Coulson, J; Marrow, P; Smith, R J; Clark, M; Sharples, S D; Lainé, S J

    2016-01-01

    Spatially resolved acoustic spectroscopy (SRAS) is a laser ultrasonic technique that shows qualitative contrast between grains of different orientation, illustrating the sensitivity of acoustic waves to the material structure. The technique has been improved significantly on determining the full orientation of multigrain cubic metals, by comparing the measured surface acoustic wave (SAW) velocity to a pre-calculated model. In this paper we demonstrate the ability of this technique to determine the orientation of hexagonal structure crystals, such as magnesium and titanium based alloys. Because of the isotropy of the SAW velocity on the basal plane (0001) of hexagonal crystals, the slowness surface is shown as a circle. As the plane moves from (0001) towards (112-bar0) or towards (101-bar0), the slowness surface gradually turns into an oval. These acoustic properties increase the difficulty in orientation determination. The orientation results of a grade 1 commercially pure titanium by SRAS is presented, with comparison with electron backscattered diffraction (EBSD) results. Due to the nature of SAWs on hexagonal structure crystals, only the results of Euler angles 1 and 2 are discussed. The error between SRAS and EBSD is also investigated. (paper)

  15. Determination of trace quantities of uranium in rocks mass spectrometric isotope dilution technique

    International Nuclear Information System (INIS)

    Kakazu, Mauricio Hiromitu

    1980-01-01

    A detailed experimental investigation on the thermionic emission of uranium deposited on a single flat type rhenium filament has been carried out. The study was aimed at determining the influence of various forms of deposition on the emission sensitivity and thermal stability of U + , UO + and UO 2 + ions. Based on these investigations, a technique, involving an addition of a small quantity of colloidal suspension of graphite on top of the uranyl nitrate sample deposited, was chosen because of its higher, emission sensitivity for uranium metal ions. The experimental parameters of the technique were optimised and the technique was employed in the determination of trace quantities of uranium in rock samples using mass spectrometric isotope dilution method. For the mass spectrometric isotope dilution analysis National Bureau of Standards uranium isotopic standard NBS-U 970 was employed as a tracer, where as the mass discrimination effect in the uranium isotope analysis was corrected using the uranium isotopic standard NBS-U500. Uranium was determined in each of the seven granite samples from Wyoming, USA and two USGS standard rocks. The precision of the analysis was found to be ±1% . The uranium values obtained on the rock samples were compared with the analyses of other investigators. Influence of the sample splitting on the uranium analysis was discussed in the light of the analytical results obtained.(author)

  16. Evaluation of an innovative radiographic technique - parallel profile radiography - to determine the dimensions of dentogingival unit

    Directory of Open Access Journals (Sweden)

    Sushama R Galgali

    2011-01-01

    Full Text Available Background: Maintenance of gingival health is a key factor for longevity of the teeth as well as of restorations. The physiologic dentogingival unit (DGU, which is composed of the epithelial and connective tissue attachments of the gingiva, functions as a barrier against microbial entry into the periodontium. Invasion of this space triggers inflammation and causes periodontal destruction. Despite the clinical relevance of the determination of the length and width of the DGU, there is no standardized technique. The length of the DGU can be either determined by histologic preparations or by transgingival probing. Although width can also be assessed by transgingival probing or with an ultrasound device, they are either invasive or expensive Aims: This study sought to evaluate an innovative radiographic exploration technique - parallel profile radiography - for measuring the dimensions of the DGU on the labial surfaces of anterior teeth. Materials and Methods: Two radiographs were made using the long-cone parallel technique in ten individuals, one in frontal projection, while the second radiograph was a parallel profile radiograph obtained from a lateral position. The length and width of the DGU was measured using computer software. Transgingival probing (trans-sulcular was done for these same patients and length of the DGU was measured. The values obtained by the two methods were compared. Pearson product correlation coefficient was calculated to examine the agreement between the values obtained by PPRx and transgingival probing. Results: The mean biologic width by the parallel profile radiography (PPRx technique was 1.72 mm (range 0.94-2.11 mm, while the mean thickness of the gingiva was 1.38 mm (range 0.92-1.77 mm. The mean biologic width by trans-gingival probing was 1.6 mm (range 0.8-2.2mm. Pearson product correlation coefficient (r for the above values was 0.914; thus, a high degree of agreement exists between the PPRx and TGP techniques

  17. Application to Determination of Scholarship Worthiness Using Simple Multi Attribute Rating Technique and Merkle Hellman Method

    Directory of Open Access Journals (Sweden)

    Dicky Nofriansyah

    2017-10-01

    Full Text Available This research was focused on explaining how the concept of simple multi attribute rating technique method in a decision support system based on desktop programming to solve multi-criteria selection problem, especially Scholarship. The Merkle Hellman method is used for securing the results of choices made by the Smart process. The determination of PPA and BBP-PPA scholarship recipients on STMIK Triguna Dharma becomes a problem because it takes a long time in determining the decision. By adopting the SMART method, the application can make decisions quickly and precisely. The expected result of this research is the application can facilitate in overcoming the problems that occur concerning the determination of PPA and BBP-PPA scholarship recipients as well as assisting Student Affairs STMIK Triguna Dharma in making decisions quickly and accurately

  18. Markov chain Monte Carlo techniques applied to parton distribution functions determination: Proof of concept

    Science.gov (United States)

    Gbedo, Yémalin Gabin; Mangin-Brinet, Mariane

    2017-07-01

    We present a new procedure to determine parton distribution functions (PDFs), based on Markov chain Monte Carlo (MCMC) methods. The aim of this paper is to show that we can replace the standard χ2 minimization by procedures grounded on statistical methods, and on Bayesian inference in particular, thus offering additional insight into the rich field of PDFs determination. After a basic introduction to these techniques, we introduce the algorithm we have chosen to implement—namely Hybrid (or Hamiltonian) Monte Carlo. This algorithm, initially developed for Lattice QCD, turns out to be very interesting when applied to PDFs determination by global analyses; we show that it allows us to circumvent the difficulties due to the high dimensionality of the problem, in particular concerning the acceptance. A first feasibility study is performed and presented, which indicates that Markov chain Monte Carlo can successfully be applied to the extraction of PDFs and of their uncertainties.

  19. Determination of the uranium content in phosphate fertilizers by the fission track registration technique

    International Nuclear Information System (INIS)

    Rocha, A.C.S. da.

    1983-01-01

    The application of fission track registration technique (SSNTD) to determine the uranium contents in phosphate fertilizers is dealt with. Samples were prepared by the wet method and the detector used was Makrofol Kg 10μm thick. The determination of uranium in phosphate fertilizer industry is of considerable interest in environmental control. The roots of vegetables tend to absorb and accumulate uranium form soil and so the human body could be contaminated. The phosphate fertilizers were originated from the phosphate-rich apatite deposits located in the high naturally radioactive areas of Araxa and Tapira in the state of Minas Gerais, Brazil. The results obtained ranged from 11.1 to 100ppm of uranium with a total error from 8.2 to 15.7%. The thorium contributions to the total track counting were discounted, though the actual concentrations of thorium in the samples were not determined. (Author) [pt

  20. Quantitative determination of mineral coal impurities from Brazil through optical emission spectrography technique

    International Nuclear Information System (INIS)

    Clain, Almir Faria

    1982-01-01

    The aim of the present research was to develop a spectrographic technique to determine the highest possible number of the chemical elements micro-constituents of Brazilian mineral coals. The experimental technique developed corresponds to the so called total-burning procedure. Coal samples were calcined to ashes at 400°C and then totally burned in graphite electrodes by a DC arc. The spectrographic measurements were made in a Jarrell-Ash emission spectrograph, Ebert mounting type, model Mark IV. An inert atmosphere chamber (for a gaseous mixture 20% 0 2 and 80% air) and a seven step rotating sector were used as main accessories. The analytical curves for the different elements, were obtained using synthetic standards in the concentration range of 10 to 1.000 ppm, and the standards as well as the coal ashes were diluted with spectrographically pure graphite in 1:1 ratio. Seventeen coal samples from different shells and strata of Morungava and Charqueadas mines - Rio Grande do Sul State - were analyzed to test the proposed technique, being possible to determine the following elements: B, Be, Bi, Cd, Co, Cr, Cu, Ga,Pb, Ge, Mn, Mo, Ni, Sn, Sb, V, Y, Zn and Zr. The coefficient of variation was 14% in average for all the elements and the sensitivity was so that the majority of the impurities present in the coals were analyzed. (author)

  1. Nuclear techniques for determining biomass production, evaporation and transpiration, root development and nutritional value

    International Nuclear Information System (INIS)

    Niemann, E.G.; Kuehn, W.; Kaul, A.K.

    1975-01-01

    From the Institute of Radiation Botany, Hanover, some nuclear methods are presented which could be of assistance to the plant breeders in selecting for positive plant characters. Several methods have been developed for the continuous determination of biomass by means of gamma-absorption measurements in single plants as well as in experimental field plots. The response of plant growth to environmental conditions such as fertilization, irrigation, and day length, dependent on genetic parameters can easily be followed by these techniques. Primarily for the investigation of water vapour movement in soils and between soil and atmosphere under conditions of temperature inversions, a technique has been worked out using 3 H-labelled water and water vapour. The inclusion of plants in this system will allow the determination of water balance under varying environmental conditions. An autoradiographic method has been applied using 86 Rb as trace element mainly for the measurement of root distribution of trees (apple, coffee). Finally, a sequence of analytical steps are described that have been developed and used in Hanover for the selection for protein amount and quality in crop plants. Though not all of these steps include nuclear methods, the application of tracer techniques in this and other screening sequences is an invaluable help for breeders and analysts. (author)

  2. Determination of catecholamines and their metabolites by radioisotopic techniques, value in pharmacology and physiopathology

    International Nuclear Information System (INIS)

    Comoy, E.; Bohuon, C.

    1980-01-01

    At present the only way to estimate catecholamines and similar compounds at concentrations between 10 and 100 femtomoles is by the use of radioenzymatic techniques. Such methods are all based in practice on the enzymatic transformation of these substrates, in the presence of labelled S-adenosylmethionine, under the action of catechol-O-methyltrans-ferase (COMT) or phenylethanol-amine-N-methyltransferase (PNMT), which means that molecules suitable for such determinations must possess either a catechol group (catecholamines, dihydroxyphenylalanine, dihydroxyphenylacetic acid) or a phenylethanolamine group (noradrenaline, methoxynoradrenaline). At present the largest number of molecules may be estimated by methods based on the principle of O-methylation by COMT. The main processes described in the literature are examined, with special reference to the proposed means of solving problems which arise at various stages of the determination, mention is made of the many difficulties inherent in this kind of manipulation and of the limits to be expected of these tests. The immunological aspect of quantitative research on catecholamines and their derivatives is mentioned, work in this direction at present being based on radioimmunology. As a practical illustration of the many methodological studies mentioned, the application of radioisotopic techniques to in vitro exploration of the catecholamine metabolism is discussed; the contribution of these new techniques is shown particularly in the physiopathological study of certain metabolic disorders observed in man, in the pharmacodynamic study of certain molecules and in experimental studies on the central nervous system [fr

  3. Determination of Nuclear Track Parameters for LR-115 Detector by Using of MATLAB Software Technique

    International Nuclear Information System (INIS)

    AL-Jomaily, F.M.; AL-joburi, H.A.; Mheemeed, A.K.

    2013-01-01

    The nuclear track detector parameters, such as nuclear track diameter D(μm), number of track N T and area of track A T were determined by using MATLAB software technique for IR-115 detector irradiated by alpha particle from 241 Am source under 1.5, 2.5 and 3.5 MeV at etching time T B of 90, 120, 150 and 180 min.By using the image analysis of MATLAB software for nuclear track, the full width at half maximum FWHM and relative resolution R% were calculated for each energy of alpha particles.In this study, it was shown that increasing the alpha energy on the IR-115 detector leads to increased etching time T B and the dropping of R% to minimum value, and then reach a stable value before dropping at values 1.5, 2.5 MeV and unstable at 3.5 MeV. Imaging analysis by MATLAB technique which used in this study reflect good and accurate results for nuclear track detector parameters and we recommend using this technique for determination of these parameters

  4. New flowing afterglow technique for determining products of dissociative recombination: CH5+ and N2H+

    International Nuclear Information System (INIS)

    Adams, Nigel G; Molek, Chris D; McLain, Jason L

    2009-01-01

    There are discrepancies in the literature for the product distributions of electron-ion (e-i) recombination when determined using different techniques. Because of this, a new technique has been developed. This is based on the flowing afterglow, with the product neutrals detected by electron impact ionization followed by mass spectrometric detection. However, in addition to the products of recombination, there are neutrals present from ion-molecule reactions and from the gases introduced into the flow tube to create the ion of interest, which often have much greater concentrations than the products. To distinguish these products, an electron attaching gas is pulsed into the flow to transiently attach the electrons, thus quenching e-i recombination. Then the difference between the attaching gas in and out yields the product distribution. Recombination products have been detected even when their signal is as much as ∼ 10 4 less than background. Here the details of the technique are described and the possible sources of error discussed. The viability of the technique is illustrated for the recombinations of CH 5 + and N 2 H + . The latter establishes the major product as N 2 + H (95 to 100%) correcting an error in the literature. In the former case, the major channel detected is CH 4 + H (95%) which is in disagreement with a storage ring (SR) result which gave CH 3 as the major channel (68%). Possible reasons for this are discussed.

  5. Determination of arterial input function in dynamic susceptibility contrast MRI using group independent component analysis technique

    International Nuclear Information System (INIS)

    Chen, S.; Liu, H.-L.; Yang Yihong; Hsu, Y.-Y.; Chuang, K.-S.

    2006-01-01

    Quantification of cerebral blood flow (CBF) with dynamic susceptibility contrast (DSC) magnetic resonance imaging (MRI) requires the determination of the arterial input function (AIF). The segmentation of surrounding tissue by manual selection is error-prone due to the partial volume artifacts. Independent component analysis (ICA) has the advantage in automatically decomposing the signals into interpretable components. Recently group ICA technique has been applied to fMRI study and showed reduced variance caused by motion artifact and noise. In this work, we investigated the feasibility and efficacy of the use of group ICA technique to extract the AIF. Both simulated and in vivo data were analyzed in this study. The simulation data of eight phantoms were generated using randomized lesion locations and time activity curves. The clinical data were obtained from spin-echo EPI MR scans performed in seven normal subjects. Group ICA technique was applied to analyze data through concatenating across seven subjects. The AIFs were calculated from the weighted average of the signals in the region selected by ICA. Preliminary results of this study showed that group ICA technique could not extract accurate AIF information from regions around the vessel. The mismatched location of vessels within the group reduced the benefits of group study

  6. A general technique for confluence of calculational and experimental information with application to power distribution determination

    International Nuclear Information System (INIS)

    Serov, I.V.; Hoogenboom, J.E.

    1994-01-01

    Physical quantities can be obtained by utilizing different informational sources. The available information is usually associated with systematic and statistical errors. If the informational sources are utilized simultaneously, then it is possible to obtain posterior estimates of the quantities with better statistical properties than exhibited by any prior estimates. The general technique for confluence of any number possibly dependent informational sources can be developed. Insight into the nature of the informational source allows different types of data associated with the source to be improved. The formulas of the technique are presented and applied to the power distribution determination for research reactor HOR of the Delft University of Technology, employing calculational and experimental data. (authors). 5 refs., 1 tab., 5 figs

  7. Determination of damage and In vivo DNA repairing through the unicellular in gel electrophoresis technique

    International Nuclear Information System (INIS)

    Mendiola C, M.T.; Morales R, P.

    1997-01-01

    The experimental conditions were standardized for the unicellular in gel electrophoresis technique setting up (EUG) at the Cellular Radiobiology laboratory. Preliminary experiments were realized with human cells and mouse which were exposed to ionizing radiation or hydroxide peroxide (H 2 O 2 ) to induce DNA damage and to verify the technique performance. It was analysed the In vivo repairing kinetics of induced damage by gamma radiation in mouse leukocytes which were exposed to 137 Cs source and taking samples of peripheric blood of the tail of each mouse at different exposure times and processing them for EUG. In function of the cells proportion with damage in each time it was determined the existence of fast repairing mechanism at the first 15 minutes followed by a slight increase in the damage and a late repairing stage between 30 and 90 minutes. It was analysed this behavior and the potentiality of this In vivo system. (Author)

  8. Cardiac output determined by echocardiography in patients with cirrhosis: comparison with the indicator dilution technique

    DEFF Research Database (Denmark)

    Andersen, Ulrik B; Møller, Søren; Bendtsen, Flemming

    2003-01-01

    technique (CO(I)). METHODS: Twelve patients with cirrhosis were studied. CO(d) was measured as the spatial mean velocity of the left ventricular outflow tract, multiplied by the cross-sectional area and the heart rate. CO(I) was determined by the standard indicator dilution technique after injection of 125I...... albumin and 99mTc albumin into the right atrium and subsequent sampling from the femoral artery. RESULTS: The mean CO(d) and CO(I) were similar (7.20 vs 7.15 l/min, NS). A highly significant correlation was present between CO(d) and CO(I) (r = 0.86, P

  9. Determination of free acidity in nuclear fuel reprocessing streams by fiber optic aided spectrophotometric technique

    International Nuclear Information System (INIS)

    Ganesh, S.; Velavendan, P.; Pandey, N.K.; Kamachi Mudali, U.; Natarajan, R.

    2014-01-01

    A fiber optic aided spectrophotometric technique has been developed for the determination of free acidity in nuclear fuel reprocessing streams. The developed method is simple, accurate and applicable to all ranges of nitric acid and heavy metal concentrations relevant to the purex process. The method is based on the formation of yellow colour with an acid-sensitive indicator such as chrome azurol s, the intensity of yellow colour is proportional to the acid concentration. The system obeys Lambert-Beer's law at 455 nm in the range of acidity 1-10 M of nitric acid. The results obtained are reproducible with standard deviation 2% and relative error is less than 3%. The results obtained by the developed technique are in good agreement with those obtained by the standard procedure. This method is adaptable for remote operation and on-line monitoring. (author)

  10. Determination of phase transitions in a lyotropic liquid crystal by Positron Annihilation technique

    International Nuclear Information System (INIS)

    Castillo V, V.M.

    1994-01-01

    Positron annihilation technique was used to determine the phase transitions in a lyotropic liquid crystal, as a function of temperature. Seven different concentrations of the surfactant cetyldimethylethylammonium bromide, were studied. The liquid crystal studied consisted of a binary system, formed by the surfactant and water. Positron annihilation technique has a very high sensitivity toward changes in the microestructure, in condensed matter, this is useful in order to detect the temperatures at which phase transitions occur and the number of these, in a liquid crystalline system. Thus, phase transitions are related with changes occurred in the ortho-positronium parameters: lifetime (τ 3 ) and intensity of formation (I 3 ). Six different kinds of phases were detected in the system studied in a temperature range of 35 to 140 Centigrade degrees, those phases were: hexagonal, hexagonal-lamellae, lamellae, lamellae-cubic, nematic and anisotropic. Using optical microscopic the textures of these phases were assigned. (Author)

  11. Determination of Rare Earth Elements in Thai Monazite by Inductively Coupled Plasma and Nuclear Analytical techniques

    International Nuclear Information System (INIS)

    Busamongkol, Arporn; Ratanapra, Dusadee; Sukharn, Sumalee; Laoharojanaphand, Sirinart

    2003-10-01

    The inductively coupled plasma atomic emission spectroscopy (ICP-AES) for the determination of individual rare-earth elements (REE) was evaluated by comparison with instrumental neutron activation analysis (INAA) and x-ray fluorescence spectrometry (XRF). The accuracy and precision of INAA and ICP-AES were evaluated by using standard reference material IGS-36, a monazite concentrate. For INAA, the results were close to the certified value while ICP-AES were in good agreement except for some low concentration rare earth. The techniques were applied for the analysis of some rare earth elements in two Thai monazite samples preparing as the in-house reference material for the Rare Earth Research and Development Center, Chemistry Division, Office of Atoms for Peace. The analytical results obtained by these techniques were in good agreement with each other

  12. Technique for mass-spectrometric determination of moisture content in fuel elements and fuel element claddings

    International Nuclear Information System (INIS)

    Kurillovich, A.N.; Pimonov, Yu.I.; Biryukov, A.S.

    1988-01-01

    A technique for mass-spectroimetric determination of moisture content in fuel elements and fuek claddings in the 2x10 -4 -1.5x10 -2 g range is developed. The relative standard deviation is 0.13. A character of moisture extraction from oxide uranium fuels in the 20-700 deg C temperature range is studied. Approximately 80% of moisture is extracted from the fuels at 300 deg C. The moisture content in fuel elements with granular uranium oxide fuels is measured. Dependence of fuel element moisture content on conditions of hot vacuum drying is shown. The technique permits to optimize the fuel element fabrication process to decrease the moisture content in them. 4 refs.; 3 figs.; 2 tabs

  13. Determination of U-235 quantity in fresh fuel elements by neutron coincidence collar technique

    International Nuclear Information System (INIS)

    Almeida, M.C.M. de; Almeida, S.G. de; Marzo, M.A.S.; Moita, L.P.M.

    1990-01-01

    The U-235 quantity per lenght of fresh fuel assemblies of the Angra-I first recharge was determined by Neutron Coincidence Collar technique (N.C.C.). This technique is well-founded in fresh fuel assemblies activation by thermal neutrons from AmLi source to generate U-235 fission neutrons. These neutrons are detected by coincidence method in polyethylene structure where 18 He-3 detectors were placed. The coincidence counting results, in active mode (AmLi), showed 0,7% to standard deviation and equal to 1,49% to mass in 1000s of counting. The accuracies of different calibration methods were evaluated and compared. The results showed that the operator declared values are consistent. This evaluation was part of technical-exchange program between Safeguards Laboratory from C.N.E.N. and Los Alamos National Lab., United States. (author)

  14. Utilization of tritiated water dilution technique in determination of nitrogen partitioning in cashmere goats

    International Nuclear Information System (INIS)

    Wang Linfeng; Yang Gaiqing; Liu Ping; Zhang Shijun

    2010-01-01

    In order to investigate nitrogen partitioning in local cashmere goats, six Inner Mogolia White Cashmere goats between 2 to 2.5 years old were used to determine the nitrogen partitioning in cashmere goats. The total retained nitrogen (TN) in body, distribution of body nitrgen and hair nitrogen were measured by general digestive and metabolism method combined with tritiated water dilution technique. Results showed that the combined methods were ideal for determining body nitrgen (BN) and hair nitrogen (fur nitrogen, FN) of Cashmere goats. There were obvious significance between BN and FN in different seasons. In telogen, BN and FN partitioning was 75.7% ± 0.62% and 24.3% ± 0.62%, respectively. Whereas, it changed to 66.6% ± 2.2% and 33.4% ± 2.2% in anagen. BN partitioning decreased when the season changed from telogen to anagen, while FN partitioning increased, which indicated that more nitrogen substance was partitioned to body growth in telogen, and more nitrogen substance was distribute to cashmere growth in anagen. These transformation were related to the changing of photoperiod and some hormones, such as melatonin (MT), prolactin (PRL) and IGF-I. It could be concluded that tritiated water dilution technique can be used to detect body protein content as well as BN, combining general digestive and metabolism experiment, FN partitoning can be determined. BN and FN partitoning varied with the season in cashmere goats because of hormones changing. (authors)

  15. The validation of the Z-Scan technique for the determination of plasma glucose

    Science.gov (United States)

    Alves, Sarah I.; Silva, Elaine A. O.; Costa, Simone S.; Sonego, Denise R. N.; Hallack, Maira L.; Coppini, Ornela L.; Rowies, Fernanda; Azzalis, Ligia A.; Junqueira, Virginia B. C.; Pereira, Edimar C.; Rocha, Katya C.; Fonseca, Fernando L. A.

    2013-11-01

    Glucose is the main energy source for the human body. The concentration of blood glucose is regulated by several hormones including both antagonists: insulin and glucagon. The quantification of glucose in the blood is used for diagnosing metabolic disorders of carbohydrates, such as diabetes, idiopathic hypoglycemia and pancreatic diseases. Currently, the methodology used for this determination is the enzymatic colorimetric with spectrophotometric. This study aimed to validate the use of measurements of nonlinear optical properties of plasma glucose via the Z-Scan technique. For this we used samples of calibrator patterns that simulate commercial samples of patients (ELITech ©). Besides calibrators, serum glucose levels within acceptable reference values (normal control serum - Brazilian Society of Clinical Pathology and Laboratory Medicine) and also overestimated (pathological control serum - Brazilian Society of Clinical Pathology and Laboratory Medicine) were used in the methodology proposal. Calibrator dilutions were performed and determined by the Z-Scan technique for the preparation of calibration curve. In conclusion, Z-Scan method can be used to determinate glucose levels in biological samples with enzymatic colorimetric reaction and also to apply the same quality control parameters used in biochemistry clinical.

  16. Track Detection Technique Using CR-39 for Determining Depleted Uranium in Biological Specimens

    International Nuclear Information System (INIS)

    Murbat, S.M.

    2013-01-01

    Track detecting technique using CR-39 track detector has been implemented for determining depleted uranium concentration in biological specimens (tissues, bones, and blood) of patients infected with cancer diseases. Results were compared with specimens of patients infected with conventional diseases (noncancerous). Specimens were collected from middle and south of Iraq have been contaminated with depleted uranium in the Gulf war in 1991. Results show that this technique is efficient for determining depleted uranium concentration in biological specimens. It was found that all studies samples determine for patients infected with cancer diseases contain a high concentration of depleted uranium (more than the international standard) comparing with noncancerous diseases. Moreover, it was found that persons infected with Leukemia show more sensitive to uranium concentrations to induce the diseases (66-202 ppb), while (116- 1910 ppb) concentrations were needed for inducing cancer diseases in organs and tissues. Result confirmed the correlation between cancerous diseases and the munitions made of depleted uranium used in the Gulf war in 1991 leads to contaminate the Iraqi environment and causes a high risk against people in Iraq.

  17. ATR technique, an appropriate method for determining the degree of conversion in dental giomers

    International Nuclear Information System (INIS)

    Prejmerean, Cristina; Prodan, Doina; Vlassa, Mihaela; Prejmerean, Vasile; Cuc, Stanca; Moldovan, Marioara; Streza, Mihaela; Buruiana, Tinca; Colceriu, Loredana

    2016-01-01

    Dental light-curing giomers were developed to combine the favourable properties of diacrylic resin composites (DRCs) and glass-ionomer cements (GICs) in a single material and to eliminate their inherent drawbacks. Giomers are characterized by their aesthetic appearance, high mechanical properties, adhesion to dental tissues as well as fluoride release and recharge abilities. The qualities of the giomers are greatly influenced by the level of conversion of the component resins. Infrared spectroscopy is one of the most largely used techniques for the determination of the degree of conversion in resin-based dental materials. However different results were obtained due to the performances of the used methods. The present work presents the determination of conversion degree in a series of dental copolymers and their corresponding giomers using transmission Fourier transform infrared spectroscopy (FTIR) and an attenuated total reflection technique (ATR) technique, respectively, the main aim being the study of the influence of the materials composition and of the light curing modes upon the achieved conversion in the cured giomers. Beautifil II commercial giomer was used as a control. A halogen lamp and a diode-blue LED lamp were used for the curing of the materials. The results showed that the composition of the resins greatly influenced the conversion. The highest conversions (up to 79%) were obtained in the case of the experimental giomers which contained the experimental Bis-GMA urethane analogue, followed by the Beautifil II giomer (61%) and experimental giomers based on commercial Bis-GMA (up to 50%), respectively. The resins light-cured by using the diode-blue LED lamp presented slightly higher conversions than the resins cured by halogen lamp. The study demonstrates the possibility to evaluate easily and reproducibly the conversion in light-curing composite materials with complex chemical composition and structure, particularly in the case of giomers by using the

  18. Crystal growth by Bridgman and Czochralski method of the ferromagnetic quantum critical material YbNi4P2

    Science.gov (United States)

    Kliemt, K.; Krellner, C.

    2016-09-01

    The tetragonal YbNi4P2 is one of the rare examples of compounds that allow the investigation of a ferromagnetic quantum critical point. We report in detail on two different methods which have been used to grow YbNi4P2 single crystals from a self-flux. The first, a modified Bridgman method, using a closed crucible system yields needle-shaped single crystals oriented along the [001]-direction. The second method, the Czochralski growth from a levitating melt, yields large single crystals which can be cut in any desired orientation. With this crucible-free method, samples without flux inclusions and a resistivity ratio at 1.8 K of RR1.8K = 17 have been grown.

  19. New Technique Of Determination Of Biogenic Fraction In Liquid Fuels By The 14C Method

    International Nuclear Information System (INIS)

    Krajcar Bronic, I.; Baresic, J.; Horvatincic, N.; Kristof, R.; Kozar Logar, J.

    2015-01-01

    According to the EU Directive 2009/28/EC all (liquid) fuels have to contain at least 10 percent of bio-fuel, i.e., blend of biogenic origin, by 2020. 14C method is the most reliable method of determination of the biogenic fraction in fuels and various measurement techniques can be applied. A technique of direct measurement of the 14C content in liquid fuel is simple and fast but has main disadvantage: different liquid colours cause different quenching and changes in the measurement efficiency. Here we have described a new technique that uses liquids of different colours to construct modern and background calibration curves, MCC and BCC, respectively, by measuring count rates and SQP values of various modern and fossil liquids. Several types of fossil fuel, pure benzine and benzene (used as 14C-free background for 14C dating) were used for BCC, and various brands of domestic oil (vegetable, sunflower, olive, pumpkin), bioethanol and benzene prepared from modern samples were used MCC construction. The procedure for the unknown sample consists of: 1) measurement of the count rate and the SQP value, 2) calculation of background and modern count rates corresponding to the measured SQP value based on the BCC and MCC curves, respectively, and 3) the ratio of net count rates of the unknown sample and the modern net count rate at the same SQP represents the fraction of the biogenic component in the liquid. All samples should be measured under the same conditions. In our case these are: UltimaGold F scintillator, the ratio sample:scintillator (10 mL:10 mL), low-potassium glass vials of 20 mL volume, spectra recorded by LSC Quantulus and evaluated in the window 124 - 570. Lowest detectable biogenic fraction is 0.5 %. The technique depends neither on the fossil matrix or the biogenic additive types. The results are in good agreement with those obtained by different evaluation technique. (author).

  20. A new technique for determining orientation and motion of a 2-D, non-planar magnetopause

    Directory of Open Access Journals (Sweden)

    A. Blagau

    2010-03-01

    Full Text Available For a four-point mission like Cluster, the differences in position and time when the satellites detect the magnetopause or any other discontinuity, can be used to infer the discontinuity local orientation, thickness and motion. This timing technique, commonly assuming a planar geometry, offers an independent check for various single-spacecraft techniques. In the present paper we propose an extension of the timing method, capable of determining in a self-consistent way the macroscopic parameters of a two-dimensional, non-planar discontinuity. Such a configuration can be produced by a local bulge or indentation in the magnetopause, or by a large amplitude wave traveling on this surface, and is recognized in Cluster data when the single spacecraft techniques provide different individual normals contained roughly in the same plane. The model we adopted for the magnetopause assumes a layer of constant thickness of either cylindrical or parabolic shape, which has one or two degrees of freedom for the motion in the plane of the individual normals. The method was further improved by incorporating in a self-consistent way the requirement of minimum magnetic field variance along the magnetopause normal. An additional assumption, required in a previously proposed non-planar technique, i.e. that the non-planarity has negligible effects on the minimum variance analysis, is thus avoided. We applied the method to a magnetopause transition for which the various planar techniques provided inconsistent results. By contrast, the solutions obtained from the different implementations of the new 2-D method were consistent and stable, indicating a convex shape for the magnetopause. These solutions perform better than the planar solutions from the normal magnetic field variance perspective. The magnetopause dynamics and the presence of a non-zero normal magnetic field component in the analyzed event are discussed.

  1. Analytical techniques for determination and control of silica content in the water in thermal power plants

    Directory of Open Access Journals (Sweden)

    Ignjatović Nataša R.

    2015-01-01

    Full Text Available Ultrapure water with minimum contents of impurities is used for the preparation of steam in thermal power plants. More recently it has been found that the corrosion process is also influenced by sodium ions, chloride ions, and all forms of silicon in water. At higher temperatures and under high pressure the less soluble compounds of silicon are extracted, which form deposits on the walls of the boiler, the piping system and the turbine blades. Silicon is found in water in the form of different types (species which are characterized by specific physical and chemical properties. Distinctions can be made between highly reactive species of ionic (silicate anions and molecular forms (silicic acid and relatively inert types (suspended, colloidal, and polymerized silicon. The determination of various forms of silicon in water is a complex analytical task. This paper covers relevant research in the field of silicon specification analysis. Maintaining the unchanged, original composition of silicon species during various stages of analysis (sample collection, storage, and conservation has been given special attention. A large number of methods and procedures have been developed for the analysis of species of silicon, including chromatographic, spectroscopic and electrochemical techniques and combinations thereof. The techniques used for determining both the total amount and individual forms of silicon have been singled out. There is also an overview of the coupled techniques used most frequently in practice by using the methodology which involves preliminary separation of species and then individual specification. The paper offers an overview of analytical properties, advantages and disadvantages of the most representative analytical methods developed specifically for the analysis of silicon species in ultrapure water. The most important studies focusing on the silicon species in water have been highlighted and presented in detail. The determination of

  2. Simultaneous Absorptance and Thermal-Diffusivity Determination of Optical Components with Laser Calorimetry Technique

    Science.gov (United States)

    Wang, Yanru; Li, Bincheng

    2012-11-01

    The laser calorimetry (LCA) technique is used to determine simultaneously the absorptances and thermal diffusivities of optical components. An accurate temperature model, in which both the finite thermal conductivity and the finite sample size are taken into account, is employed to fit the experimental temperature data measured with an LCA apparatus for a precise determination of the absorptance and thermal diffusivity via a multiparameter fitting procedure. The uniqueness issue of the multiparameter fitting is discussed in detail. Experimentally, highly reflective (HR) samples prepared with electron-beam evaporation on different substrates (BK7, fused silica, and Ge) are measured with LCA. For the HR-coated sample on a fused silica substrate, the absorptance is determined to be 15.4 ppm, which is close to the value of 17.6 ppm, determined with a simplified temperature model recommended in the international standard ISO11551. The thermal diffusivity is simultaneously determined via multiparameter fitting to be approximately 6.63 × 10-7 m2 · s-1 with a corresponding square variance of 4.8 × 10-4. The fitted thermal diffusivity is in reasonably good agreement with the literature value (7.5 × 10-7 m2 · s -1). Good agreement is also obtained for samples with BK7 and Ge substrates.

  3. [Assisted human reproduction techniques: determination of parentage and users in comparative law].

    Science.gov (United States)

    Germán Zurriaráin, Roberto

    2011-01-01

    The paper undertakes the determination of parentage and users of assisted reproduction techniques in comparative law, particularly in three European Union countries: Italy, France and Spain. The idea of artificially conceived child protection, present in the Italian provision, is substituted, partially in French law, and totally in Spanish law, by an exclusively individualistic outlook, configuring a true ″right to maternity″ for married women and for those not living with a male partner (single women, divorced or widowed) or with a female partner (lesbians), and for women inseminated artificially by the semen of the husband before or after their death, and for women already having culminated their fertile life.

  4. Determination of wear metals in engine oil by PIXE and RBS technique

    Energy Technology Data Exchange (ETDEWEB)

    Alkofahi, M M [Physics Dept., Yarmouk university, Irbid, (Jordan)

    1995-10-01

    The constituents of fresh and used engine oil were determined by PIXE and RBS techniques using 2 MeV He{sup ++} ion beams. The concentration of generated wear metals in used engine oil was measured as a function of running kilometers. The fresh oil was found to contain the elements: Si, P, S, Cl, K, Ca, and Fe. In addition to theses elements, Pb and Br were found in the used oil. Changes in the concentrations of S, Zn and Br were noticed as the running kilometers increased. 6 figs., 2 tabs.

  5. Determination of elements in industrial waste sample and TENORM using XRF Technique in Nuclear Malaysia

    International Nuclear Information System (INIS)

    Paulus, W.; Sarimah Mahat; Meor Yusoff Meor Sulaiman

    2011-01-01

    Industrial waste such as aluminium dross and TENORM waste, oil sludge has been used as sample in this research. Determination of main elements by using X-Ray Fluorescence (XRF) in Material Technology Group, Malaysian Nuclear Agency. Results shows that main elements in these samples, aluminium and silicon, respectively. Thereby, this research shows that XRF can be considered as one of the techniques that can be used in waste characterization and furthermore, it can help researchers and engineer in the research related to waste treatment especially radioactive waste. (author)

  6. A Simple Technique for Determining the pH of Whole Cigarette Smoke

    Directory of Open Access Journals (Sweden)

    Dong J

    2014-12-01

    Full Text Available A new technique has been developed to determine the pH of whole cigarette smoke. In this technique, whole smoke from ten cigarettes was trapped in 300 mL water containing 1% (w/v sodium chloride and the pH was determined on the resulting aqueous suspension of cigarette smoke. Two impingers with an extra coarse porosity fritted disc were used to dispense the smoke in the aqueous trapping medium. Cigarettes were smoked on a 20-port Borgwaldt RM 20/CS smoking machine using modified FTC (Federal Trade Commission conditions. The puff volume was adjusted to take a 35 mL puff as measured through the cigarette and the collection traps. This new technique accounts for the contributions to smoke pH from both the vapor phase and the particulate phase of smoke. The repeatability of this new technique was determined on eighteen replicates of a commercially available non-menthol, filter cigarette. Each measurement was done on a different day to check for a possible drift in pH with time. The mean pH value for the chosen sample was found to be 4.97 with a standard deviation of 0.07 pH units. The smoke pH values for over 150 commercially available cigarette brands with a variety of “tar” levels were determined. The smoke pH values had a range from 4.6 to 5.5, with an average of 4.79 and a maximum standard deviation of 0.10 pH units. An experimental flue cured cigarette had a smoke pH of around 5.0, while an experimental Burley cigarette had a smoke pH of 5.4. No correlation between smoke pH and “tar” or total particulate matter (TPM and between pH and nicotine levels was found. The purpose of the present study was to develop a practical, relatively simple laboratory method to measure the pH of a water solution of whole smoke, and was not intended to reflect, or have direct relevance for any biochemical or biological phenomena such as inhalability of smoke, flavor perception, nicotine ab-sorption, etc.”

  7. Vapor pressure determination of liquid UO/sub 2/ using a boiling point technique

    International Nuclear Information System (INIS)

    Bober, M.; Singer, J.

    1987-01-01

    By analogy with the classic boiling point method, a quasi-stationary millisecond laser-heating technique was applied to measure the saturated vapor pressure curve of liquid UO/sub 2/ in the temperature range of 3500 to 4500 K. The results are represented by log rho (MPa)=5.049 - 23 042/T (K), which gives an average heat of vaporization of 441 kJ/mol and a normal boiling point of 3808 K. In addition, spectral emissivities of liquid UO/sub 2/ were determined as a function of the temperature at the pyrometer wavelengths of 752 and 1064 nm

  8. Determination of wall wear of glassmelting furnaces by a nuclear technique

    International Nuclear Information System (INIS)

    Harsanyi, Gyoergy; Kodolanyi, Andras; Leitner, Laszlo

    1984-01-01

    A new in-service inspection technique of glassmelting furnaces is reported. Isotope-labelled refractory tank blocks were prepared, tested experimentally, and built into the furnace. Sup(60)Co isotope tracer was used. The residual wall thickness of the labelled blocks were determined by periodical radiation dose measurements. No environmental or health damage is caused by the specific activity of 3.7 - 4 Bq/g of the labelled furnace blocks, the dose rate in a distance of 1 m from the wall was as low as 0.05 mR/h. (P.J.)

  9. Determination of the hydrodynamic and morphological parameters of the Luyano River using radiotracer techniques

    International Nuclear Information System (INIS)

    Valcarcel, Lino; Alberro, Nancy; Rodriguez, Maydel; Herrero, Zahily; Borroto, Jorge; Hernandez, Anel; Dominguez, Judith; Derivet, Milagros; Flores, Pedro; Cuesta, Jaime; Griffith, Jose

    2011-01-01

    The hydrodynamic and morphological parameters (the times of travel, velocities and flowrates of the waters, and the average widths, cross sections and depths) in the middle segment of the river Luyano were determined combining the employment of sodium pertechnectate (Na 99m TcO 4 ) as radiotracer with other conventional techniques. The results were used for the calibration of the expanded Streeter and Phelps model of the river. In the work, the methodology and the main results obtained during the journey realized between the second fortnight of March and the first of April 2009 are presented. (Author)

  10. Determination of some process parameters in a tyre-cord plant using radiotracer technique

    International Nuclear Information System (INIS)

    Kirti; Madhavankutti, C.K.; Eapen, A.C.

    1979-01-01

    In the process industry, it is often necessary to study the process parameters such as the residence time, flow rate, etc., under different operating conditions and equipment. The tracer technique represents in this respect an outstanding and even sometimes singular means of determining some of the above parameters. A method consisting of the introduction of a radioactive tracer at the input of a flow system under study and subsequently determining the distribution of activity with time at the output end is described. The form of the activity time curve depends on the parameters of the installation and the mode of operation. A study conducted at a multi-stage viscose rayon processing plant is described in detail. (auth.)

  11. OSM-Classic : An optical imaging technique for accurately determining strain

    Science.gov (United States)

    Aldrich, Daniel R.; Ayranci, Cagri; Nobes, David S.

    OSM-Classic is a program designed in MATLAB® to provide a method of accurately determining strain in a test sample using an optical imaging technique. Measuring strain for the mechanical characterization of materials is most commonly performed with extensometers, LVDT (linear variable differential transistors), and strain gauges; however, these strain measurement methods suffer from their fragile nature and it is not particularly easy to attach these devices to the material for testing. To alleviate these potential problems, an optical approach that does not require contact with the specimen can be implemented to measure the strain. OSM-Classic is a software that interrogates a series of images to determine elongation in a test sample and hence, strain of the specimen. It was designed to provide a graphical user interface that includes image processing with a dynamic region of interest. Additionally, the stain is calculated directly while providing active feedback during the processing.

  12. Square Wave Voltammetry: An Alternative Technique to Determinate Piroxicam Release Profiles from Nanostructured Lipid Carriers.

    Science.gov (United States)

    Otarola, Jessica; Garrido, Mariano; Correa, N Mariano; Molina, Patricia G

    2016-08-04

    A new, simple, and fast electrochemical (EC) method has been developed to determine the release profile of piroxicam, a nonsteroidal anti-inflammatory drug, loaded in a drug delivery system based on nanostructured lipid carriers (NLCs). For the first time, the samples were analyzed by using square wave voltammetry, a sensitive EC technique. The piroxicam EC responses allow us to propose a model that explains the experimental results and to subsequently determine the amount of drug loaded into the NLCs formulation as a function of time. In vitro drug release studies showed prolonged drug release (up to 5 days), releasing 60 % of the incorporated drug. The proposed method is a promising and stable alternative for the study of different drug delivery systems. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Determination of low concentrations of thorium in granites using X-ray fluorescence technique

    International Nuclear Information System (INIS)

    Shigematsu, H.M.; Sato, I.M.; Iyer, S.S.

    1981-03-01

    An analytical method for the accurate determination of low concentrations of thorium in rocks using X-ray fluorescence technique, was developed. A tungsten tube was utilized for the production of X-rays. The samples were prepared in the form of double layer pressed pellets using boric acid as a binding agent. The concentration of thorium was determined by measuring the intensity of the characteristic first order Th L α line. The calibration was carried out with USGS rock standards AGV-1, GSP-1 and G-2. Seven granite rocks samples from Granite Mountains of Wyoming, USA, supplied by Dr. Stuckless. Also were analysed. The results obtained were compared with values obtained in others laboratories using different analytical methods. The analyses show that the thorium is concentrated in accessory minerals and presented a non-uniform distribution, making sampling an important factor in the analysis of thorium. A discussion of the precision and accuracy of the method is presented. (Author) [pt

  14. Comparison of techniques for the determination of conversion during suspension polymerization reactions

    Directory of Open Access Journals (Sweden)

    J. C. Santos

    2008-06-01

    Full Text Available The determination of conversion during suspension polymerization reactions is not an easy task due to the heterogeneity of the reaction medium and the tendency of particles to agglomerate rapidly when stirring is stopped. Usually, bulk polymerization in ampoules is employed to study the kinetics of suspension polymerization reactions. In this work, a comparison of different techniques for the determination of conversion during suspension polymerization reactions is presented. Results showed a good agreement between the conversion obtained by gravimetry during styrene suspension polymerization and on-line conversion monitoring data using fiber-optic based Raman Spectroscopy. Nevertheless, the polymerization rate of styrene bulk polymerization carried out in ampoules was higher than the real reaction rate of styrene suspension polymerization due to slightly higher reaction temperatures. Simulation results using the experimental temperature data in a mathematical model confirmed these results.

  15. Novel approaches to determining residual stresses by ultramicroindentation techniques: Application to sandblasted austenitic stainless steel

    International Nuclear Information System (INIS)

    Frutos, E.; Multigner, M.; Gonzalez-Carrasco, J.L.

    2010-01-01

    This research addresses the determination of residual stresses in sandblasted austenitic steel by ultramicroindentation techniques using a sharp indenter, of which the sensitivity to residual stress effects is said to be inferior to that of spherical ones. The introduction of an angular correction in the model of Wang et al. which relates variations in the maximum load to the presence of residual stresses is proposed. Similarly, the contribution to the hardness of grain size refinement and work hardening, developed as a consequence of the severe plastic deformation during blasting, is determined in order to avoid overestimation of the residual stresses. Measurements were performed on polished cross sections along a length of several microns, thus obtaining a profile of the residual stresses. Results show good agreement with those obtained by synchrotron radiation on the same specimens, which validates the method and demonstrates that microindentation using sharp indenters may be sensitive to the residual stress effect.

  16. Novel approaches to determining residual stresses by ultramicroindentation techniques: Application to sandblasted austenitic stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Frutos, E. [Centro de Bioingenieria, Biomateriales y Nanomedicina, CIBER-BBN, Instituto de Salud Carlos III (Spain)] [Centro Nacional de Investigaciones Metalurgicas, CENIM-CSIC, 28040 Madrid (Spain); Multigner, M. [Centro Nacional de Investigaciones Metalurgicas, CENIM-CSIC, 28040 Madrid (Spain)] [Centro de Bioingenieria, Biomateriales y Nanomedicina, CIBER-BBN, Instituto de Salud Carlos III (Spain); Gonzalez-Carrasco, J.L., E-mail: jlg@cenim.csic.es [Centro Nacional de Investigaciones Metalurgicas, CENIM-CSIC, 28040 Madrid (Spain)] [Centro de Bioingenieria, Biomateriales y Nanomedicina, CIBER-BBN, Instituto de Salud Carlos III (Spain)

    2010-07-15

    This research addresses the determination of residual stresses in sandblasted austenitic steel by ultramicroindentation techniques using a sharp indenter, of which the sensitivity to residual stress effects is said to be inferior to that of spherical ones. The introduction of an angular correction in the model of Wang et al. which relates variations in the maximum load to the presence of residual stresses is proposed. Similarly, the contribution to the hardness of grain size refinement and work hardening, developed as a consequence of the severe plastic deformation during blasting, is determined in order to avoid overestimation of the residual stresses. Measurements were performed on polished cross sections along a length of several microns, thus obtaining a profile of the residual stresses. Results show good agreement with those obtained by synchrotron radiation on the same specimens, which validates the method and demonstrates that microindentation using sharp indenters may be sensitive to the residual stress effect.

  17. Determination of radon and thoron permeability through some plastics by track technique

    Energy Technology Data Exchange (ETDEWEB)

    Hafez, A.-F.; Somogyi, G.

    1986-01-01

    Experiments have been performed to study the usefulness of several types of plastic foils as filter to separate radon and thoron. Time-integrated alpha-activity measurements have been carried out by using the so-called ''can-technique'' equipped with both LR-115 and CR-39 track detectors. The track density observed on the detectors, taken as a measure of radon activity concentration, has been determined as a function of the thickness of filter foils. The radon permeability and the thoron separation factors have been determined. It is shown that various plastic foils exhibit considerable differences in radon diffusion coefficient owing to their different chemical structures. Among the plastic foils investigated the polyethylene proved to have the highest gas diffusion coefficient.

  18. Determination of 36Cl/Cl ratio in ground water using the accelerator mass spectrometry technique

    International Nuclear Information System (INIS)

    Sharma, Suman; Deodhar, A.S.; Saravana Kumar, U.; Surendran, P.; Shrivastava, A.; Gupta, A.K.; Nair, J.P.; Yadav, M.L.; Hemalatha, M.; Sparrow, H.; Mahata, K.; Thomas, R.G.; Bhagwat, P.V.; Kailas, S.; Kale, R.M.

    2009-01-01

    The Accelerator Mass Spectrometry (AMS) programme using the 14 MV Pelletron Accelerator at Mumbai has been initiated with major emphasis on the determination of 36 Cl in water samples, of interest to hydrology and environment. In order to carry out the AMS measurement, a beam chopper to cut down beam intensity by a factor of 20 has been developed and commissioned. A multi-anode gas -si detector has been built to separate 36 Cl from the interfering 36 S. A new TPS system has been procured to operate the machine in the GVM mode. Standard and blank samples from Prime lab, Purdue have been employed in these measurements to standardise the technique for 36 Cl/Cl ratio determination. The detector was calibrated using the stable 35,37 Cl ions. The background 36 Cl in the system has been measured using the blank sample from Purdue and it was estimated that the ratio of 36 Cl/Cl was of the order of 10 -13 in the present setup. Ground water samples collected from South India were converted to AgCl and put in the SNICS ion source for the AMS measurements. These ground water samples, with 14 C content estimated to be in the range of 1 to 4 pMC indicate that the samples may be more than 35,000 years old. Using the AMS technique we have determined the 36 Cl/Cl ratio values for these ground water samples. They are found to range between 2 to 5 x 10 -12 . Additional measurements are planned to determine the age of the water samples and to understand the reasons for the observed high values of 36 Cl in these samples. (author)

  19. The capillary adhesion technique: a versatile method for determining the liquid adhesion force and sample stiffness

    Directory of Open Access Journals (Sweden)

    Daniel Gandyra

    2015-01-01

    Full Text Available We report a novel, practical technique for the concerted, simultaneous determination of both the adhesion force of a small structure or structural unit (e.g., an individual filament, hair, micromechanical component or microsensor to a liquid and its elastic properties. The method involves the creation and development of a liquid meniscus upon touching a liquid surface with the structure, and the subsequent disruption of this liquid meniscus upon removal. The evaluation of the meniscus shape immediately before snap-off of the meniscus allows the quantitative determination of the liquid adhesion force. Concurrently, by measuring and evaluating the deformation of the structure under investigation, its elastic properties can be determined. The sensitivity of the method is remarkably high, practically limited by the resolution of the camera capturing the process. Adhesion forces down to 10 µN and spring constants up to 2 N/m were measured. Three exemplary applications of this method are demonstrated: (1 determination of the water adhesion force and the elasticity of individual hairs (trichomes of the floating fern Salvinia molesta. (2 The investigation of human head hairs both with and without functional surface coatings (a topic of high relevance in the field of hair cosmetics was performed. The method also resulted in the measurement of an elastic modulus (Young’s modulus for individual hairs of 3.0 × 105 N/cm2, which is within the typical range known for human hair. (3 Finally, the accuracy and validity of the capillary adhesion technique was proven by examining calibrated atomic force microscopy cantilevers, reproducing the spring constants calibrated using other methods.

  20. Determination of trace uranium in human hair by nuclear track detection technique

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Moon, Jong Hwa; En, Zinaida; Cho, Seung Yeon; Kang, Sang Hoon; Lee, Jae Ki

    2001-01-01

    The aim of this study is to describe a usefulness of nuclear analytical technique in assessing and comparing the concentration levels through the analysis of uranium using human hair sample in the field of environment. A fission track detection technique was applied to determine the uranium concentration in human hair. Hair samples were collected from two groups of people - a) workers not dealing with uranium directly, and b) workers possibly contaminated with uranium. The concentration of 235 U for the first group varied from <1 to 39 ng/g and the second group can be estimated up to the level of μg/g. Radiographs of heavy-duty work samples contained high dense 'hot spots' along a single hair. After washing in acetone and distilled water, external contamination was not totally removed. Insoluble uranium compounds were not completely washed out. The (n, f)-radiography technique, having high sensitivity, and capable of getting information on uranium content at each point of a single hair, is an excellent tool for environmental monitoring

  1. Determination of true coincidence correction factors using Monte-Carlo simulation techniques

    Directory of Open Access Journals (Sweden)

    Chionis Dionysios A.

    2014-01-01

    Full Text Available Aim of this work is the numerical calculation of the true coincidence correction factors by means of Monte-Carlo simulation techniques. For this purpose, the Monte Carlo computer code PENELOPE was used and the main program PENMAIN was properly modified in order to include the effect of the true coincidence phenomenon. The modified main program that takes into consideration the true coincidence phenomenon was used for the full energy peak efficiency determination of an XtRa Ge detector with relative efficiency 104% and the results obtained for the 1173 keV and 1332 keV photons of 60Co were found consistent with respective experimental ones. The true coincidence correction factors were calculated as the ratio of the full energy peak efficiencies was determined from the original main program PENMAIN and the modified main program PENMAIN. The developed technique was applied for 57Co, 88Y, and 134Cs and for two source-to-detector geometries. The results obtained were compared with true coincidence correction factors calculated from the "TrueCoinc" program and the relative bias was found to be less than 2%, 4%, and 8% for 57Co, 88Y, and 134Cs, respectively.

  2. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    Science.gov (United States)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  3. Simultaneous determination of Ra-226, Ra-228 and Pb-210 using a successive coprecipitations techniques

    International Nuclear Information System (INIS)

    Vilhena Schayer Sabino, C. de; Kastner, S.M.S.; Amaral, A.M.

    1990-01-01

    Several techniques for determination of Ra-226, Ra228 and Pb-210. were developed and used in routine at CDTN in the laboratories of radiochemistry. The matrixes were: water and industrial wastes. Some problems of these techniques were the time spent for analyses and chemical separations, interferents, among others. Now-a-days the method in routine developed here is the one of successive coprecipitations, followed α and β countings of the Ra-226 and Ra-228 daughters. This method is based on coprecipitation, purification of barium radium sulfate with EDTA in acetic solution. Lead is dissolved, radium remains precipitated and suffers a new purification and the time for growing of their daughters is waited to be performed the simultaneous α and β countings for Ra-226 and Ra-228 determination. Pb-210 is analyzed in the floating of the first purification with a carrier of bismuth, and the time for Bi-210 growing is waited. Then it is precipitated as hydroxid, purified as phosphate and the β counting of Bi-210 is done. (author) [pt

  4. A heuristic ranking approach on capacity benefit margin determination using Pareto-based evolutionary programming technique.

    Science.gov (United States)

    Othman, Muhammad Murtadha; Abd Rahman, Nurulazmi; Musirin, Ismail; Fotuhi-Firuzabad, Mahmud; Rajabi-Ghahnavieh, Abbas

    2015-01-01

    This paper introduces a novel multiobjective approach for capacity benefit margin (CBM) assessment taking into account tie-line reliability of interconnected systems. CBM is the imperative information utilized as a reference by the load-serving entities (LSE) to estimate a certain margin of transfer capability so that a reliable access to generation through interconnected system could be attained. A new Pareto-based evolutionary programming (EP) technique is used to perform a simultaneous determination of CBM for all areas of the interconnected system. The selection of CBM at the Pareto optimal front is proposed to be performed by referring to a heuristic ranking index that takes into account system loss of load expectation (LOLE) in various conditions. Eventually, the power transfer based available transfer capability (ATC) is determined by considering the firm and nonfirm transfers of CBM. A comprehensive set of numerical studies are conducted on the modified IEEE-RTS79 and the performance of the proposed method is numerically investigated in detail. The main advantage of the proposed technique is in terms of flexibility offered to an independent system operator in selecting an appropriate solution of CBM simultaneously for all areas.

  5. A Heuristic Ranking Approach on Capacity Benefit Margin Determination Using Pareto-Based Evolutionary Programming Technique

    Directory of Open Access Journals (Sweden)

    Muhammad Murtadha Othman

    2015-01-01

    Full Text Available This paper introduces a novel multiobjective approach for capacity benefit margin (CBM assessment taking into account tie-line reliability of interconnected systems. CBM is the imperative information utilized as a reference by the load-serving entities (LSE to estimate a certain margin of transfer capability so that a reliable access to generation through interconnected system could be attained. A new Pareto-based evolutionary programming (EP technique is used to perform a simultaneous determination of CBM for all areas of the interconnected system. The selection of CBM at the Pareto optimal front is proposed to be performed by referring to a heuristic ranking index that takes into account system loss of load expectation (LOLE in various conditions. Eventually, the power transfer based available transfer capability (ATC is determined by considering the firm and nonfirm transfers of CBM. A comprehensive set of numerical studies are conducted on the modified IEEE-RTS79 and the performance of the proposed method is numerically investigated in detail. The main advantage of the proposed technique is in terms of flexibility offered to an independent system operator in selecting an appropriate solution of CBM simultaneously for all areas.

  6. Determination of the uranium concentration in water samples by the technique of fission track recording

    International Nuclear Information System (INIS)

    Geraldo, L.P.

    1979-01-01

    The technique of fission track register was developed for the determination of micrograms of uranium. The Makrofol KG, a synthetic plastic made by Bayer, was used as the detector and the wet method was utilized. The detector calibration curve allows the determination of the uranium concentration in a sample within an interval from 8.0 to 0.4μgU/L, the total error ranging from 3.3% to 29.0% respectively. The method was used in the determination of the uranium content in various water samples, obtained from various sources like rivers, sea etc. in the state of Sao Paulo, Brazil. Results were compared with those obtained by other authors using different methods. The average concentration found in sea waters (3.27 +- 9.12μgU/l) by this method is compatible with the international average accepted value of 3.3μgU/l, irrespective of site and depth. The determination of the uranium content by fission track counting has proved to be very convenient. (Author) [pt

  7. DEVELOPMENT OF RAPID TECHNIQUE FOR DETERMINATION OF THE TOTAL MINERALIZATION OF NATURAL WATERS

    Directory of Open Access Journals (Sweden)

    T. A. Kuchmenko

    2015-01-01

    Full Text Available A new approach has been proposed for rapid and easy evaluation of a indicator of quality and properties of natural water - soluble salt content (mineralization. The method of quartz crystal microbalance is employed at load of the mass-sensitive resonator electrode (BAW-type with investigated water. The degree of correlation between the various indicators related to the contents of salts and insoluble compounds and the level of mineralization obtained by the standard method (gravimetry has been studied. A procedure for salt weighing by single sensor at unilateral load with small sample of natural water has been developed. The optimal conditions for measurement is established using the design of experiment by model 23 . The possibilities of quartz crystal microbalance for determination of non-volatile compounds in the water are described. The calibration of piezosensor is produced by standard solution NaCl (c = 1.000 g / dm3 at optimal conditions of experiment. The adequacy and accuracy of proposed technique is assessed by the correlation between the results of quartz crystal microbalance and conductometry. The correlation between indicators of mineralization established by quartz crystal microbalance and gravimetry is found. It has been obtained an equation that can be used to calculate the standard indicator of the mineralization by the results of a quartz crystal microbalance using single sensor. The approaches to enhance the analytical capabilities of the developed technique for water with low and high mineralization are proposed. The metrological characteristics of quartz crystal microbalance of insoluble compounds in natural water are estimated. A new technique of determination of the mass concentration of the dry residue in water with a conductivity of 0.2 mS or above has been developed, which can be used for rapid analysis of the water at nonlaboratory conditions and in the laboratory for rapid obtaining the information about a sample.

  8. Determination of stability constants of lanthanide nitrate complex formation using a solvent extraction technique

    International Nuclear Information System (INIS)

    Andersson, S.; Ekberg, C.; Liljenzin, J.O.; Nilsson, M.; Skarnemark, G.; Eberhardt, K.

    2006-01-01

    For lanthanides and actinides, nitrate complex formation is an important factor with respect to the reprocessing of nuclear fuels and in studies that treat partitioning and transmutation/conditioning. Different techniques, including microcalorimetry, various kinds of spectroscopy, ion-exchange and solvent extraction, can be used to determine stability constants of nitrate complex formation. However, it is uncommon that all lanthanides are studied at the same time, using the same experimental conditions and technique. The strengths of the complexes are different for lanthanides and actinides, a feature that may assist in the separation of the two groups. This paper deals with nitrate complex formation of lanthanides using a solvent extraction technique. Trace amounts of radioactive isotopes of lanthanides were produced at the TRIGA Mainz research reactor and at the Institutt for Energiteknikk in Kjeller, Norway (JEEP II reactor). The extraction of lanthanide ions into an organic phase consisting of 2, 6-bis-(benzoxazolyl)-4-dodecyloxylpyridine, 2-bromodecanoic acid and tert-butyl benzene as a function of nitrate ion concentration in the aqueous phase was studied in order to estimate the stability constants of nitrate complex formation. When the nitrate ion concentration is increased in the aqueous phase, the nitrate complex formation starts to compete with the extraction of metal ions. Thus the stability constants of nitrate complex formation can be estimated by measuring the decrease in extraction and successive fitting of an appropriate model. Extraction curves for La, Ce, Pr, Nd, Pm, Sm, Eu, Gd, Dy, Ho and Er were obtained and stability constants for their nitrate complex formation were estimated. Tb, Tm, Yb and Lu were also investigated, but no stability constants could be determined. The distribution ratios for the metal ions at low nitrate ion concentration were obtained at the same time, showing the effect of lanthanide contraction resulting in decreasing

  9. Establishment of a Pcr Technique for Determination of Htlv-1 Infection in Paraffin-Embedded Tissues

    Directory of Open Access Journals (Sweden)

    M Rastin

    2007-04-01

    Full Text Available Introduction: HTLV-1 , the first known human retrovirus belongs to oncovirus subfamily of retroviruses. The major characteristic of HTLV-1 is its highly restricted geographic prevalence. Northern part of Khorasan is an endemic region of HTLV-1 infection. Epidemiological studies can help in designing preventive programs for HTLV-1 infection. The aim of this study was the establishment of a PCR technique for determination of HTLV-1 infection in paraffin-embedded tissues. Methods: In this experimental laboratory study for establishment of a technique, PCR was initially optimized using Beta-actin primers on various formalin fixed paraffin-embedded tissues from liver, spleen, skin and lymph nodes. The optimized concentration of Mgcl2 was 2mm, primer was 8 pmol. Optimized concentration of DNA was different according to the kind of tissue. HTLV-1 infection was determined by applying tax, pol, env and LTR primers on 50 paraffin-embedded lymph node tissues . The reporoducibility of this technique was shown for skin and lymph node tissues infected with HTLV-1. Resuls: In 50 lymph node tissues, one case with pathologic diagnosis of NHL was positive with all 5 sets of primers (tax, Pol, env and LTR primers and the other case was positive with only two sets of tax primers but was negative with pol, env and LTR primers. The prevalence of infection was 2% among lymph node specimens. (1 of 50 specimens and if the second case is considered, the prevalence would be 4%. Conclusion: Comparison of the results of this study with another study on blood specimens (seroprevalence2.3% was not statistically significant thus confirming the results of one another. (P=0.883

  10. Determination of the protonation enthalpy of humic acid by calorimetric titration technique

    International Nuclear Information System (INIS)

    Kimuro, Shingo; Kirishima, Akira; Sato, Nobuaki

    2015-01-01

    Graphical abstract: The thermodynamic quantities of protonation of humic acid were determined by the combination of potentiometric titration and calorimetric titration. It was observed that the protonation enthalpy and Gibbs free energy had been affected by pH of solution. As a result, the thermodynamics of the protonation reaction of humic acid is influenced by the polyelectrolyte effect and the heterogeneity. - Highlights: • We applied calorimetric titration technique to the protonation of humic acid. • The thermodynamic quantities of protonation of humic acid were determined. • The protonation enthalpy of humic acid is affected by the heterogeneity. • Gibbs free energy of the protonation is affected by the polyelectrolyte effect. - Abstract: In this study, the calorimetric titration technique was used to determine the protonation enthalpy of two reference humic acids and polyacrylic acid. First, we obtained the apparent protonation constant of two kinds of humic acid purchased from IHSS (International Humic Substances Society) and polyacrylic acid by potentiometric titration. Second, we obtained the protonation enthalpy of them by calorimetric titration. The protonation enthalpy of humic acid was affected by pH and the ionic strength of bulk solution. From the comparison of ΔH between humic acid and polyacrylic acid, it was concluded that the pH dependence of ΔH is attributed to the heterogeneity of humic acid. And ΔH of phenolic hydroxyl group in humic acid is strongly influenced by the electric double layer of humic acid’s surface. This is considered to be a reason of the ionic strength dependence of ΔH. On the other hand, Gibbs free energy of the protonation of humic acid is affected by the electrostatic attraction with the progress of dissociation of functional groups such as carboxyl group and phenolic hydroxyl group. Consequently, the thermodynamics of the protonation of humic acid is affected by the polyelectrolyte effect and the

  11. A review of cooperative and uncooperative spacecraft pose determination techniques for close-proximity operations

    Science.gov (United States)

    Opromolla, Roberto; Fasano, Giancarmine; Rufino, Giancarlo; Grassi, Michele

    2017-08-01

    The capability of an active spacecraft to accurately estimate its relative position and attitude (pose) with respect to an active/inactive, artificial/natural space object (target) orbiting in close-proximity is required to carry out various activities like formation flying, on-orbit servicing, active debris removal, and space exploration. According to the specific mission scenario, the pose determination task involves both theoretical and technological challenges related to the search for the most suitable algorithmic solution and sensor architecture, respectively. As regards the latter aspect, electro-optical sensors represent the best option as their use is compatible with mass and power limitation of micro and small satellites, and their measurements can be processed to estimate all the pose parameters. Overall, the degree of complexity of the challenges related to pose determination largely varies depending on the nature of the targets, which may be actively/passively cooperative, uncooperative but known, or uncooperative and unknown space objects. In this respect, while cooperative pose determination has been successfully demonstrated in orbit, the uncooperative case is still under study by universities, research centers, space agencies and private companies. However, in both the cases, the demand for space applications involving relative navigation maneuvers, also in close-proximity, for which pose determination capabilities are mandatory, is significantly increasing. In this framework, a review of state-of-the-art techniques and algorithms developed in the last decades for cooperative and uncooperative pose determination by processing data provided by electro-optical sensors is herein presented. Specifically, their main advantages and drawbacks in terms of achieved performance, computational complexity, and sensitivity to variability of pose and target geometry, are highlighted.

  12. Sex determination of Pohnpei Micronesian kingfishers using morphological and molecular genetic techniques

    Science.gov (United States)

    Kesler, Dylan C.; Lopes, I.F.; Haig, Susan M.

    2006-01-01

    Conservation-oriented studies of Micronesian Kingfishers (Todiramphus cinnamominus) have been hindered by a lack of basic natural history information, despite the status of the Guam subspecies (T. c. cinnamominus) as one of the most endangered species in the world. We used tissue samples and morphometric measures from museum specimens and wild-captured Pohnpei Micronesian Kingfishers (T. c. reichenbachii) to develop methods for sex determination. We present a modified molecular protocol and a discriminant function that yields the probability that a particular individual is male or female. Our results revealed that females were significantly larger than males, and the discriminant function correctly predicted sex in 73% (30/41) of the individuals. The sex of 86% (18/21) of individuals was correctly assigned when a moderate reliability threshold was set. Sex determination using molecular genetic techniques was more reliable than methods based on morphology. Our results will facilitate recovery efforts for the critically endangered Guam Micronesian Kingfisher and provide a basis for sex determination in the 11 other endangered congeners in the Pacific Basin.

  13. Determination of Ca/P molar ratio in hydroxyapatite (HA) by X-ray fluorescence technique

    Energy Technology Data Exchange (ETDEWEB)

    Scapin, Marcos A.; Guilhen, Sabine N.; Cotrim, Marycel E.B.; Pires, Maria Ap. F., E-mail: mascapin@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Hydroxyapatite (HA) is a mineral composed of calcium phosphate employed for endodontics, restorative dentistry and other applications in orthopedics and prosthesis. Additionally, this biomaterial is an inexpensive but efficient adsorbent for the removal of heavy metals and other unwanted species of contaminated liquid effluents. This is especially interesting when low-cost effective remediation is required. A Ca / P molar ratio of 1.667 is consistent with the theoretical Ca / P ratio for calcium hydroxyapatite with a compositional formula of Ca{sub 10}(PO{sub 4}){sub 6}(OH){sub 2}, which properties are well discussed in the literature. The aim of this work was to implement and validate a methodology for simultaneous determination of major and minor constituents in the hydroxyapatite (HA) as well as providing the Ca / P molar ratio. To accomplish these achievements, wavelength dispersive X-ray fluorescence spectroscopy (WDXRF) was applied. This is a non-destructive technique that requires no chemical treatment, enabling fast chemical analysis in a wide variety of samples, with no hazardous waste being generated as a result of the process of determination. A standard reference material from NIST (SRM 1400 – Bone Ash) was used to validate the methodology for the determination of magnesium, phosphorus, potassium, calcium, iron, zinc, strontium and the Ca / P ratio in HA samples by WDXRF. The Z-score test was applied as a statistical tool and showed that the calculated values were of less than 1.8 for all the measured analytes. (author)

  14. Determination of alpha-naphthol by an oscillating chemical reaction using the analyte pulse perturbation technique

    International Nuclear Information System (INIS)

    Yang Wu; Sun Kanjun; Lv Weilian; Bo Lili; He Xiaoyan; Suo Nan; Gao Jinzhang

    2005-01-01

    An analytical method for the determination of alpha-naphthol (α-NP) is proposed by the sequential perturbation caused by different amounts of alpha-naphthol on the oscillating chemical system involving the Cu(II)-catalyzed oscillating reaction between hydrogen peroxide and sodium thiocyanate in an alkaline medium with the aid of continuous-flow stirred tank reactor (CSTR). The method relies on the linear relationship between the changes in the oscillation amplitude of the chemical system and the concentration of alpha-naphthol. The use of the analyte pulse perturbation technique permits sequential determinations in the same oscillating system owing to the expeditiousness with which the steady state is regained after each perturbation. The calibration curve obeys a linear equation very well when the concentration of alpha-naphthol is over the range 0.034-530 umol/L (r = 0.9991). Influences of temperature, injection points, flow rate and reaction variables on the oscillating system are investigated in detail and the possible mechanism of action of alpha-naphthol to the chemical oscillating system is also discussed. The method has been successfully used for the determination of α-naphthol in carbaryl hydrolysates

  15. Determination of Ca/P molar ratio in hydroxyapatite (HA) by X-ray fluorescence technique

    International Nuclear Information System (INIS)

    Scapin, Marcos A.; Guilhen, Sabine N.; Cotrim, Marycel E.B.; Pires, Maria Ap. F.

    2015-01-01

    Hydroxyapatite (HA) is a mineral composed of calcium phosphate employed for endodontics, restorative dentistry and other applications in orthopedics and prosthesis. Additionally, this biomaterial is an inexpensive but efficient adsorbent for the removal of heavy metals and other unwanted species of contaminated liquid effluents. This is especially interesting when low-cost effective remediation is required. A Ca / P molar ratio of 1.667 is consistent with the theoretical Ca / P ratio for calcium hydroxyapatite with a compositional formula of Ca 10 (PO 4 ) 6 (OH) 2 , which properties are well discussed in the literature. The aim of this work was to implement and validate a methodology for simultaneous determination of major and minor constituents in the hydroxyapatite (HA) as well as providing the Ca / P molar ratio. To accomplish these achievements, wavelength dispersive X-ray fluorescence spectroscopy (WDXRF) was applied. This is a non-destructive technique that requires no chemical treatment, enabling fast chemical analysis in a wide variety of samples, with no hazardous waste being generated as a result of the process of determination. A standard reference material from NIST (SRM 1400 – Bone Ash) was used to validate the methodology for the determination of magnesium, phosphorus, potassium, calcium, iron, zinc, strontium and the Ca / P ratio in HA samples by WDXRF. The Z-score test was applied as a statistical tool and showed that the calculated values were of less than 1.8 for all the measured analytes. (author)

  16. Optimization of quantitative waste volume determination technique for hanford waste tank closure

    International Nuclear Information System (INIS)

    Monts, David L.; Jang, Ping-Rey; Long, Zhiling; Okhuysen, Walter P.; Norton, Olin P.; Gresham, Lawrence L.; Su, Yi; Lindner, Jeffrey S.

    2011-01-01

    The Hanford Site is currently in the process of an extensive effort to empty and close its radioactive single-shell and double-shell waste storage tanks. Before this can be accomplished, it is necessary to know how much residual material is left in a given waste tank and the uncertainty with which that volume is known. The Institute for Clean Energy Technology (ICET) at Mississippi State University is currently developing a quantitative in-tank imaging system based on Fourier Transform Profilometry, FTP. FTP is a non-contact, 3-D shape measurement technique. By projecting a fringe pattern onto a target surface and observing its deformation due to surface irregularities from a different view angle, FTP is capable of determining the height (depth) distribution (and hence volume distribution) of the target surface, thus reproducing the profile of the target accurately under a wide variety of conditions. Hence FTP has the potential to be utilized for quantitative determination of residual wastes within Hanford waste tanks. In this paper, efforts to characterize the accuracy and precision of quantitative volume determination using FTP and the use of these results to optimize the FTP system for deployment within Hanford waste tanks are described. (author)

  17. Determination of NAPL contamination and evolution of remediation by means nuclear techniques

    International Nuclear Information System (INIS)

    Balcazar, M.; Pena, P.; Lopez, A.; Flores, J. H.; Villegas, D.; Schubert, M.; Knoller, K.

    2008-01-01

    In this work the application of two nuclear techniques is presented: Natural radioactive tracer and stable isotopics tracer, that allow the localization and delimitation of the contamination in ground and underground water for hydrocarbons denominated NAPL. The work was carry out on the whole and with access permission to facilities and technical information, in a storage center and distribution of fuel of hydrocarbons where occurred a spill for hydrocarbons, approaching actions of remediation that allow to the date to fulfill the normative one applicable. By means of measurement of 222 Rn, in situ, it was possible to be related its ground concentration to the degree of contamination previously determined; the evaluation of 222 Rn in underground water in group with the determination of stable isotope δ 34 S, δ 18 O and δ 13 C as well as the dissolved inorganic coal allowed to locate the contamination source in underground water to 100 m of depth in the aquifer and to determine the existence of a natural bioremediation. (Author)

  18. On the Decay Ratio Determination in BWR Stability Analysis by Auto-Correlation Function Techniques

    International Nuclear Information System (INIS)

    Behringer, K.; Hennig, D.

    2002-11-01

    A novel auto-correlation function (ACF) method has been investigated for determining the oscillation frequency and the decay ratio in BWR stability analyses. The neutron signals are band-pass filtered to separate the oscillation peak in the power spectral density (PSD) from background. Two linear second-order oscillation models are considered. These models, corrected for signal filtering and including a background term under the peak in the PSD, are then least-squares fitted to the ACF of the previously filtered neutron signal, in order to determine the oscillation frequency and the decay ratio. Our method uses fast Fourier transform techniques with signal segmentation for filtering and ACF estimation. Gliding 'short-term' ACF estimates on a record allow the evaluation of uncertainties. Numerical results are given which have been obtained from neutron data of the recent Forsmark I and Forsmark II NEA benchmark project. Our results are compared with those obtained by other participants in the benchmark project. The present PSI report is an extended version of the publication K. Behringer, D. Hennig 'A novel auto-correlation function method for the determination of the decay ratio in BWR stability studies' (Behringer, Hennig, 2002)

  19. Determination of the optimal tolerance for MLC positioning in sliding window and VMAT techniques

    International Nuclear Information System (INIS)

    Hernandez, V.; Abella, R.; Calvo, J. F.; Jurado-Bruggemann, D.; Sancho, I.; Carrasco, P.

    2015-01-01

    Purpose: Several authors have recommended a 2 mm tolerance for multileaf collimator (MLC) positioning in sliding window treatments. In volumetric modulated arc therapy (VMAT) treatments, however, the optimal tolerance for MLC positioning remains unknown. In this paper, the authors present the results of a multicenter study to determine the optimal tolerance for both techniques. Methods: The procedure used is based on dynalog file analysis. The study was carried out using seven Varian linear accelerators from five different centers. Dynalogs were collected from over 100 000 clinical treatments and in-house software was used to compute the number of tolerance faults as a function of the user-defined tolerance. Thus, the optimal value for this tolerance, defined as the lowest achievable value, was investigated. Results: Dynalog files accurately predict the number of tolerance faults as a function of the tolerance value, especially for low fault incidences. All MLCs behaved similarly and the Millennium120 and the HD120 models yielded comparable results. In sliding window techniques, the number of beams with an incidence of hold-offs >1% rapidly decreases for a tolerance of 1.5 mm. In VMAT techniques, the number of tolerance faults sharply drops for tolerances around 2 mm. For a tolerance of 2.5 mm, less than 0.1% of the VMAT arcs presented tolerance faults. Conclusions: Dynalog analysis provides a feasible method for investigating the optimal tolerance for MLC positioning in dynamic fields. In sliding window treatments, the tolerance of 2 mm was found to be adequate, although it can be reduced to 1.5 mm. In VMAT treatments, the typically used 5 mm tolerance is excessively high. Instead, a tolerance of 2.5 mm is recommended

  20. A comparison between destructive and non-destructive techniques in determining coating thickness

    Science.gov (United States)

    Haider, F. I.; Suryanto; Ani, M. H.; Mahmood, M. H.

    2018-01-01

    Measuring coating thickness is an important part in research works related to coating applications. In general, techniques for measuring coating thickness may be divided into destructive and non-destructive methods which are commonly used depending on the applications. The objective of this study is to compare two methods measuring the coating thickness of electroplating copper coating on the austenitic stainless-steel substrate. The electroplating was carried out in a solution containing 200 g/L CuSO4, 100 g/L H2SO4 at room temperature and current of 40mA/cm2 during 20, 40, 60, 80 and 100 mins as coating periods. And the coating thickness was measured by two methods, cross sectional analysis as a destructive technique and weight gain as a non-destructive technique. The results show that at 20 mins coating time interval, the thickness measured by cross sectional method was 16.67 μm and by weight gain method was 17.37 μm, with difference of 0.7 μm and percentage error of 4.11%. This error increased to 5.27% at 100mins time interval, where the values of the thickness measured by cross sectional and weight gain were 86.33 μm and 81.9 μm respectively, and the difference was 4.43 μm. Moreover, though the weight gain method is fast and gives the indication for the termination of a coating process, information regarding the uniformity, porosity and the presence of cracks cannot be obtained. On the other hand, determining the coating thickness using destructive method will damage the sample.

  1. Determination of hydrogen diffusivity and permeability in W near room temperature applying a tritium tracer technique

    International Nuclear Information System (INIS)

    Ikeda, T.; Otsuka, T.; Tanabe, T.

    2011-01-01

    Tungsten is a primary candidate of plasma facing material in ITER and beyond, owing to its good thermal property and low erosion. But hydrogen solubility and diffusivity near ITER operation temperatures (below 500 K) have scarcely studied. Mainly because its low hydrogen solubility and diffusivity at lower temperatures make the detection of hydrogen quite difficult. We have tried to observe hydrogen plasma driven permeation (PDP) through nickel and tungsten near room temperatures applying a tritium tracer technique, which is extremely sensible to detect tritium diluted in hydrogen. The apparent diffusion coefficients for PDP were determined by permeation lag times at first time, and those for nickel and tungsten were similar or a few times larger than those for gas driven permeation (GDP). The permeation rates for PDP in nickel and tungsten were larger than those for GDP normalized to the same gas pressure about 20 and 5 times larger, respectively.

  2. Atomic structure of large angle grain boundaries determined by quantitative X-ray diffraction techniques

    International Nuclear Information System (INIS)

    Fitzsimmons, M.R.; Sass, S.L.

    1988-01-01

    Quantitative X-ray diffraction techniques have been used to determine the atomic structure of the Σ = 5 and 13 [001] twist boundaries in Au with a resolution of 0.09 Angstrom or better. The reciprocal lattices of these boundaries were mapped out using synchrotron radiation. The atomic structures were obtained by testing model structures against the intensity observations with a chi square analysis. The boundary structure were modeled using polyhedra, including octahedra, special configurations of tetrahedra and Archimedian anti-prisms, interwoven together by the boundary symmetry. The results of this work point to the possibility of obtaining general rules for grain boundary structure based on X-ray diffraction observations that give the atomic positions with high resolution

  3. An Analytical Technique to Determine the Potential for Moisture Accumulation in Deactivated Structures

    International Nuclear Information System (INIS)

    MINICHAN, RL

    2004-01-01

    This paper describes an analytical technique developed to predict an order of magnitude volume of moisture accumulation in massive structures after deactivation. This work was done to support deactivation of a Department of Energy nuclear materials processing facility. The structure is a four-story, concrete building with a rectangular footprint that is approximately 250m long by 37m wide by 22m high. Its walls are 1.2m thick. The building will be supplied with unconditioned ventilation air after deactivation. The objective of the work was to provide a cost effective engineering evaluation to determine if the un-conditioned ventilation air would result in condensate accumulating inside the building under study. The analysis described is a simple representation of a complex problem. The modeling method is discussed in sufficient detail to allow its application to the study of similar structures

  4. An acoustic technique for the determination of liquor level in tanks

    International Nuclear Information System (INIS)

    Watson, J.; Jones, T.L.

    1980-02-01

    The design, development and application of a prototype suitable for the measurement of liquor levels in tanks is described. The technique involves directing an acoustic pulse down a constraining tube to the liquor surface and measuring the time of return of the reflected pulse. Using the equipment it is possible to determine the position of a solid surface with a total error of less than 1 mm. The prototype instrument was used to measure the volume of liquors contained in rectangular slab tanks used for accountancy purposes at Dounreay Nuclear Power Development Establishment. The total error obtained in an individual measurement of volume was less than 0.2 litres (95% confidence limits). The instrument may be used as a replacement for a Pneumercator system in existing installations. (author)

  5. Determination techniques of characteristics of brittle fracture for materials on the CMEA 1-35 problem

    International Nuclear Information System (INIS)

    Makhutov, N.A.; Tananov, A.I.; Koshelev, P.F.; Zatsarinnyj, V.V.

    1981-01-01

    The problems concerning the development and improvement of the investigation techniques and the evaluation of the resistance to brittle fracture of a wide class of materials (the reactor ones, in particular) under different conditions of loading using modern test means are considered in the review. It is reflected in the plan of works on the theme 1-35.3 ''Development of the methods of determination of resistance to brittle fracture of the materials and elements of construct Specialists from CMEA member-countries took an active part in its implementation. The development of the 1-35.3 theme presupposes the creation of scientific bases of calculation methods of the details of machines and elements of constructions according to the criteria of resistance to brittle fracture. The results obtained when using the methods of fracture mechanics are of significant importance in the substantiation of strength and admissible defectiveness of large-size constructions operating under the extremum conditions [ru

  6. Determination of Effective Criteria for Location Selection of Kiln Wood Drying Plants by AHP Technique

    Directory of Open Access Journals (Sweden)

    Rahim Mohebbi

    2011-12-01

    Full Text Available This study was aimed at determining the effective criteria for location selection of wood drying plants in Iran. For this purpose, after review and field visit of the industries, 35 key indicators were identified. These criteria were divided into five major groups as: materials, infrastructure, technical, economical and instructional indices. The priority rates of these criteria and sub-criteria were evaluated by AHP technique. The results indicated that among 35 effective sub-criteria in location selection of the plants, the sub-criteria of quality of raw materials(0.152, purchasing raw materials, land cost, profitability, reliability of supply, and sales had the highest priorities, which were rated as 0.118, 0.105, 0.067, 0.061 and 0.057, respectively

  7. Technique for determination of the time constant for relay radioisotope instruments

    International Nuclear Information System (INIS)

    Gol'din, M.L.; Shestialtynov, V.K.

    1981-01-01

    A technique for calculating time constant of a gamma relay used in radio isotope automatics is suggested. It is shown that the time constant of a radioisotope relay device (RRD) mainly depends on parameters of the intergrating circuit ratemeter. Considering the ratemeter as a real communication channel with a limited transmission band, the equation for the active front duration at a ratemeter outlet when applying abrupt voltage to its inlet is obtained. From the complex transmission function of a ratemeter the upper boundary cyclic transmission frequency the substitution of which in the equation of the active front durationg ives the RRD time constant is determined. On the example of calculating the ratemeter for the GR-6 gamma relay a satisfactory coincidence of calculational results with the certificate data is shown [ru

  8. Single injection techniques in determining age-related changes in porcine renal function

    International Nuclear Information System (INIS)

    Robbins, M.E.C.

    1984-01-01

    Glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) were determined in 32 anaesthetised female Large White pigs, aged 4-24 months, from the plasma disappearance curves of [sup(99m)Tc]DTPA and [ 131 I]hippuran respectively. Clearance was also monitored by external counting over the heart. GFR and ERPF increased markedly with age in pigs up to 12 months old, reaching mean values of 242.06 +- 5.89 and 919.39 +- 79.01 mL/min. In pigs aged 12-24 months ERPF increased slightly but renal function remained essentially unchanged after 1 yr of age. These results for renal function were similar to previous estimates, using continuous infusion techniques inferring that GFR and ERPF could be accurately monitored using single injection procedures. (author)

  9. A heuristic technique to determine corrective control actions for reactive power flows

    Energy Technology Data Exchange (ETDEWEB)

    Trigo, Angel L.; Martinez, Jose L.; Riquelme, Jesus; Romero, Esther [Department of Electrical Engineering, University of Sevilla (Spain)

    2011-01-15

    This paper presents a sensitivity-based heuristic tool designed to help the system operator in the reactive power flow control problem. The objective of the proposed technique is to determine control actions to ensure that reactive power flows in transmission-subtransmission boundary transformers remain within specified limits, satisfying the new regulatory constraints imposed in most of deregulated markets. With this new constraint the utilities want to guarantee that the utility is able to satisfy its own reactive power requirements, avoiding reactive power flows through long distances in order to reduce the well known disadvantages that reactive power circulation has in the system. A 5-bus tutorial system is used to present the proposed algorithm. The results of the application of the proposed technique to the IEEE 118 buses system and to a regional subtransmission network of the South of Spain are reported and analyzed. In this last actual case, the aim is to maintain reactive power flows in transmission/distribution transformers between those limits set by the Spanish Regulation. A comparison between the proposed tool and a conventional OPF is discussed. (author)

  10. Determination of Total Volatile Basic Nitrogen (TVB-N Content in Beef by Hyperspectral Imaging Technique

    Directory of Open Access Journals (Sweden)

    Liu Shanmei

    2016-01-01

    Full Text Available Non-destructive determination of TVB-N content in beef using hyperspectral imaging (HSI technique was evaluated. In order to create a robust model to predict the TVB-N content in beef, partition of sample set, spectral pretreatment, and the optimum wavelength selection were discussed. After the beef sample set was parted by concentration gradient (CG algortithm, and the spectra of beef samples were preprocessed by standard normalized variate (SNV combined with auto scale(AS, the partial least square regression (PLSR model was established using the full spectral range, which had the best prediction abilities with Rcv2 of 0.9124, Rp2 of 0.8816, RMSECV of 1.5889, and RMSEP of 1.7719, respectively. After the optimum wavelengths which is closely related to the TVB-N content of beef samples was obtained using the competitive adaptive re-weighted (CARS algorithm, a new PLSR model was established using the optimum wavelengths, which had outstanding prediction abilities with Rcv2 of 0.9235, Rp2 of 0.9241, RMSECV of 1.4881, and RMSEP of 1.4882, respectively.The study showed that HSI is a powerful technique to predict the TVB-N content in beef by a nondestructive way.

  11. Determination of melting point of vegetable oils and fats by differential scanning calorimetry (DSC technique.

    Directory of Open Access Journals (Sweden)

    Nassu, Renata Tieko

    1999-02-01

    Full Text Available Melting point of fats is used to characterize oils and fats and is related to their physical properties, such as hardness and thermal behaviour. The present work shows the utilization of DSC technique on the determination of melting point of fats. In a comparison with softening point (AOCS method Cc 3-25, DSC values were higher than those obtained by AOCS method. It has occurred due to the fact that values obtained by DSC technique were taken when the fat had melted completely. DSC was also useful for determining melting point of liquid oils, such as soybean and cottonseed ones.

    El punto de fusión de grasas es usado para caracterizar aceites y grasas, y está relacionado con sus propiedades físicas, tales como dureza y comportamiento térmico. El presente trabajo muestra la utilización de la técnica de Calorimetría Diferencial de Barrido (DSC en la determinación del punto de fusión de grasas. En comparación con el punto de ablandamiento (AOCS método Cc 3-25, los valores de DSC fueron más altos que los obtenidos por los métodos de AOCS. Esto ha ocurrido debido al hecho que los valores obtenidos por la técnica de DSC fueron tomados cuando la grasa había fundido completamente. DSC fue también útil para determinar puntos de fusión de aceites líquidos, tales como los de soya y algodón.

  12. Determination of hydrogen content of petroleum products from Tema Oil Refinery using neutron backscatter technique

    International Nuclear Information System (INIS)

    Salifu, A. S.

    2015-01-01

    The hydrogen content of hydrocarbon materials is very important in several areas of industrial process such as mining, vegetable oil extraction and crude oil exploration and refining. A fast and more universal technique based on thermal neutron reflection was employed to determine the total hydrogen contents of petroleum samples from Tema Oil Refinery (TOR) and Crude oil samples from Jubilee field and Nigeria. The experimental set-up consisted of a source-holder housing a 1Ci Am-Be neutron source and a He-3 neutron detector. Two geometrical arrangements were considered and their sensitivities were compared. The set-up was used to measure the excess neutron count in both geometrical considerations and their reflection parameters were calculated as a function of hydrogen content of the samples. Calibration lines were deduced using liquid hydrocarbons containing well-known hydrogen and carbon contents as standards. Two linear equations were generated from the calibration lines and were used to further determine the hydrogen content of thirteen (13) petroleum samples obtained from Quality Control Department of TOR. The total hydrogen contents were found to be in the range of 7.211(hw %) - 15.069 (hw %) for vertical geometry and 7.206 (hw %) - 14.948 (hw %) for horizontal geometry respectively. The results obtained agreed constructively with other results obtained using different methodologies by other studies. The percentage error of the hydrogen contents denoted by (% E) for the various petroleum samples were also obtained and noticed to be within an acceptable range. The neutron backscatter technique was observed as an alternative and more generalized method for quality assurance and standardization in the petroleum industries

  13. Coulomb-explosion technique for determining geometrical structures of molecular ions

    International Nuclear Information System (INIS)

    Gemmell, D.S.

    1981-01-01

    Traditional experimental techniques (e.g. studies on photon absorption or emission) for determining the sterochemical structures of neutral molecules are extremeley difficult to apply to molecular ions because of problems in obtaining a sufficient spatial density of the ions to be studied. Recent high-resolution measurements on the energy and angle distributions of the fragments produced when fast (MeV) molecular-ion beams from an electrostatic accelerator dissociate (Coulomb explode) in thin foils and in gases, offer promising possibilities for deducing the sterochemical structures of the molecular ions constituting the incident beams. Bond lengths have been determined in this way for several diatomic projectiles (H 2+ , HeH + , CH + , NH + , OH + , N 2+ , O 2+ , etc.) with an accuracy of approx. 0.01 A. H 3+ has been demonstrated (for the first time) to be equilateral triangular and the interproton distance measured. Measurements on single fragments from CO 2+ , N 2 O + , C 3 H 3+ , and CH/sub n/ + have revealed the gross structures of the projectiles. An apparatus has recently been constructed at Argonne to permit precise measurements on fragments in coincidence. The apparatus has been tested on a known structure (OH 2+ ). The O-H bond length was found to be 1.0 +- 0.04 A and the H-O-H bond angle was measured as 110 --- 2 0 . These values are in excellent agreement with those found in optical experiments (0.999 A and 110.5 0 ). This Coulomb explosion technique can be expected to be refined in accuracy and to be extended to a wide range of molecular ions whose structures are inaccessible by other means

  14. Analysis of various NDT techniques to determine their feasibility for detecting thin layers of ferrite on Type 316 stainless steel

    International Nuclear Information System (INIS)

    Dudder, G.B.; Atteridge, D.G.; Davis, T.J.

    1978-09-01

    The applicability of various NDT techniques for detecting thin layers of ferrite on Type 316 stainless steel cladding was studied. The ability to detect sodium-induced ferrite layers on fuel pins would allow an experimental determination of the fuel pin temperature distribution. The research effort was broken down into three basic sections. Phase one consisted of a theoretical determination of the ferrite detection potential of each of the propsed NDT techniques. The second phase consisted of proof-of-principle experiments on the techniques that passed phase one. The third phase consisted of in-hot cell testing on actual EBR-II fuel pins. Most of the candidate techniques were eliminated in the first phase of analysis. Four potential techniques passed the initial phase of analysis but only three of these passed the second analysis phase. The three techniques that passed the proof-of-principle section of analysis were heat tinting, magnetic force and electromagnetic techniques. The electromagnetic technique was successfully demonstrated on actual fuel pins irradiated in EBR-II in the third phase of analysis while the other two techniques were not carried to the hot cell analysis phase. Results of this technique screening study indicates that an electromagnetic and/or heat tinting ferrite layer NDT technique should be readily adoptable to hot cell inspection requirements. It wasalso concluded that the magnetic force technique, while feasible, would not readily lend itself to hot cell fuel pin inspection

  15. The substitution technique applied for determining the parameters of a reactor with void

    International Nuclear Information System (INIS)

    Zdravkovic, Z.; Ivkovic, M.; Sotic, O.

    1965-12-01

    The material buckling of D 2 O-enriched uranium (2% U 235 ) system with voided fuel assembly has been determined by means of the substitution technique. The experiments were carried out in the zero power reactor RB for various lattice pitches, namely: 11.3 cm, 14 cm, and 16 cm. As a reference core the D 2 O-enriched uranium (2%U 235 ) ) system without voids has been used. The results have been analysed by the modified one-group perturbation theory using three regions in a substituted reactor (test, intermediate and reference). The perturbations in axial and radial directions due to voided fuel assembly, are also considered. In order to determine the change between diffusion coefficients in various regions (δD), additional experiments with single test fuel element were made. The lattice pitches of reference and test regions were the same. According to the algorithms given in appendices, the programmes for the ZUSE Z-23 digital computer were made. These programmes include evaluations of the change between diffusion coefficients (δD), and the axial buckling of the test lattice (author)

  16. On-line stacking techniques for the nonaqueous capillary electrophoretic determination of acrylamide in processed food

    International Nuclear Information System (INIS)

    Tezcan, Filiz; Erim, F. Bedia

    2008-01-01

    In the present study, field amplified sample stacking (FASS) techniques in the nonaqueous capillary electrophoresis method (NACE) were introduced for the on-line concentration of the acrylamide to improve acrylamide detection at 210 nm by diode-array detection. Acetonitrile (ACN) as a nonaqueous solvent permits acrylamide to be protonated through the change of its acid-base chemistry, allowing capillary electrophoretic separation of this compound. Choosing 30 mmol L -1 HClO 4 , 20 mmol L -1 NaClO 4 , 218 mmol L -1 CH 3 COOH in ACN as the separation electrolyte and employing sample stacking methods, the LOD value of acrylamide was decreased to 2.6 ng mL -1 with electrokinetic injection and 4.4 ng mL -1 with hydrodynamic injection. Optimized stacking conditions were applied to the determination of acrylamide in several foodstuffs. The method is simple, rapid, inexpensive, and widely applicable for the determination of acrylamide in food samples

  17. Determination of vitamin B12 (cobalamine) absorption by means of a simple double-isotope technique

    International Nuclear Information System (INIS)

    Hippe, E.; Brynskov, J.; Gimsing, P.; Hjelt, K.

    1986-01-01

    The background, practical instruction and clinical results of a simplified method of determining the absorption of cobalamine (vitamin B 12 ) are presented. The simultaneous administration of 57 CO-CN-cobalamine, a non-absorbable marker ( 51 CrCl 3 ), and red carmine tablets enable quantitative assessments of the cobalamine absorption by collection of a small red feaces sample. In contrast to the classical Schilling-test, this vitamin B 12 absorption test (B 12 -ABS-test) or faeces-spot-test is, independent of fasting, flushing dose, renal function and diurnal urinary collection. This is documented in a series of clinical studies. The B 12 -ABS-test provides accurate and precise results compared to the reference method (whole-body-counting). The Schilling test, on the contrary, gives approximately 50% false low values in a reference group of elderly hospitalized patients. A modification of the B 12 -ABS-test, has been used to determine the cobalamine absorption in children, and a set of age-related reference intervals have been established, together with quantitative measurements of the cobalamine absorption in children with small bowel diseases. Based on several years of practical experience, we recommend replacement of the Schilling test by this simple double-isotope technique. (author)

  18. Comparison of various techniques for the extraction and determination of antioxidants in plants.

    Science.gov (United States)

    Bajerová, Petra; Adam, Martin; Bajer, Tomáš; Ventura, Karel

    2014-04-01

    The following extraction techniques have been used for extracting antioxidants (apigenin, coumarin, esculetin, umbelliferone, bergapten, quercetin, rutin, scopoletin and xanthotoxin) from plant material: supercritical fluid extraction, pressurized liquid extraction, extraction by means of Soxhlet apparatus, ultrasonic extraction in ultrasonic bath, and by means of ultrasonic probe. The analytical method based on HPLC-UV detection for the determination of selected antioxidants was developed. For all extracts the antioxidant capacity based on the reduction of free 2,2-diphenyl-1-picrylhydrazyl radical was also determined. Comparing all results the ultrasonic probe method using 0.75 g of sample extracted by 50 mL of acetonitrile in water (30%, v/v) for 25 min at room temperature and with amplitude at 60% (equal to 90 W) without pulsation was evaluated as the best tool. The most significant indicator demonstrating this statement is the antioxidant capacity expressed as gallic acid equivalent where the ultrasonic probe method showed the best results in 10 of 16 samples. Also the operability of ultrasonic probe extraction method compared to other tested methods is more favorable. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Authenticity determination of Ag-Cu Lebanese coins using combined PIXE and RBS techniques

    International Nuclear Information System (INIS)

    Roumie, M; Nsouli, B; Assafiri, Y

    2012-01-01

    A set of silver-copper coins were investigated for their stochiometry in order to check any possible counterfeit. The studied coins are 50 Lebanese Piastres and are relatively recent, minted in 1952. They are supposed to have nominal concentration of 60 wt.% Ag and 40 wt.% Cu. In this work, it is shown the utility and capability of combining PIXE (particle induced X-ray emission) and RBS (Rutherford backscattering spectrometry) techniques to determine the elemental content and check the presence, if any, of surface layer. For this aim, 3 MeV proton beam and Al funny filter, used as x-ray absorber, were used to determine the elemental composition, based on the emission and detection of the characteristic x-rays of the corresponding elements. The first PIXE results of the supposed bulky coins showed an excess of silver composition vs. copper. In addition, the experimental protocol was checked by analyzing some other coins of known composition, such as 1-euro and 2-euro coins.

  20. Ex vivo irradiation of human blood to determine DNA damage using molecular techniques

    International Nuclear Information System (INIS)

    Montes, Angel; Agapito, Juan

    2014-01-01

    Biological dosimetry is the assessment of absorbed dose in individuals exposed to ionizing radiation from blood samples based on the radiation induced damage in cellular DNA. The aim of this study was to determine the damage in the DNA through the assessment of an experimental ex vivo assay using irradiated samples of human blood cells. For this purpose, blood samples were irradiated at low doses (<100 mGy) considering the following parameters: blood volume (3mL), temperature (37 °C) and incubation time (0.5, 2, 4, 8 and 24 h). Dose values were: 0, 12.5, 25 and 50 mGy using Cesium -137 gamma rays at 662 keV and a dose rate of 38.46 mGy/h. The qualitative damage in the genomic DNA was determined using agarose gel electrophoresis and polymerase chain reaction (PCR) for the p53 gene in a sequence of 133 pb of exon 7, related to the protein that acts in the cell repair process. The results of the qualitative analysis showed no degradation of genomic DNA; also an increase in the DNA concentration was observed up to the fourth hour of incubation, finding maximum values for all doses in the two samples. As a conclusion, the effects of ionizing radiation at doses used in this experiment do not generate a detectable damage, by means of molecular techniques such as those used in the present study. (authors).

  1. Precession technique and electron diffractometry as new tools for crystal structure analysis and chemical bonding determination

    International Nuclear Information System (INIS)

    Avilov, A.; Kuligin, K.; Nicolopoulos, S.; Nickolskiy, M.; Boulahya, K.; Portillo, J.; Lepeshov, G.; Sobolev, B.; Collette, J.P.; Martin, N.; Robins, A.C.; Fischione, P.

    2007-01-01

    We have developed a new fast electron diffractometer working with high dynamic range and linearity for crystal structure determinations. Electron diffraction (ED) patterns can be scanned serially in front of a Faraday cage detector; the total measurement time for several hundred ED reflections can be tens of seconds having high statistical accuracy for all measured intensities (1-2%). This new tool can be installed to any type of TEM without any column modification and is linked to a specially developed electron beam precession 'Spinning Star' system. Precession of the electron beam (Vincent-Midgley technique) reduces dynamical effects allowing also use of accurate intensities for crystal structure analysis. We describe the technical characteristics of this new tool together with the first experimental results. Accurate measurement of electron diffraction intensities by electron diffractometer opens new possibilities not only for revealing unknown structures, but also for electrostatic potential determination and chemical bonding investigation. As an example, we present detailed atomic bonding information of CaF 2 as revealed for the first time by precise electron diffractometry

  2. New resin gel for uranium determination by diffusive gradient in thin films technique

    International Nuclear Information System (INIS)

    Gregusova, Michaela; Docekal, Bohumil

    2011-01-01

    A new resin gel based on Spheron-Oxin chelating ion-exchanger with anchored 8-hydroxyquinoline functional groups was tested for application in diffusive gradient in thin film technique (DGT) for determination of uranium. Selectivity of uranium uptake from model carbonate loaded solutions of natural water was studied under laboratory conditions and compared with selectivity of the conventional Chelex 100 based resin gel. The affinity of Spheron-Oxin functional groups enables determination of the overall uranium concentration in water containing carbonates up to the concentration level of 10 2 mg L -1 . The effect of uranium binding to the polyacrylamide (APA) and agarose diffusive gels (AGE) was also studied. Uranium is probably bound in both gels by a weak interaction with traces of acrylic acid groups in the structure of APA gel and with pyruvic and sulfonic acid groups in the AGE gel. These sorption effects can be eliminated to the negligible level by prolonged deployment of DGT probes or by disassembling probes after the 1-2 days post-sampling period that is sufficient for release of uranium from diffusive gel and its sorption in resin gel.

  3. New resin gel for uranium determination by diffusive gradient in thin films technique

    Energy Technology Data Exchange (ETDEWEB)

    Gregusova, Michaela, E-mail: gregusova@iach.cz [Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic v.v.i., Veveri 97, 602 00 Brno (Czech Republic); Docekal, Bohumil [Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic v.v.i., Veveri 97, 602 00 Brno (Czech Republic)

    2011-01-17

    A new resin gel based on Spheron-Oxin chelating ion-exchanger with anchored 8-hydroxyquinoline functional groups was tested for application in diffusive gradient in thin film technique (DGT) for determination of uranium. Selectivity of uranium uptake from model carbonate loaded solutions of natural water was studied under laboratory conditions and compared with selectivity of the conventional Chelex 100 based resin gel. The affinity of Spheron-Oxin functional groups enables determination of the overall uranium concentration in water containing carbonates up to the concentration level of 10{sup 2} mg L{sup -1}. The effect of uranium binding to the polyacrylamide (APA) and agarose diffusive gels (AGE) was also studied. Uranium is probably bound in both gels by a weak interaction with traces of acrylic acid groups in the structure of APA gel and with pyruvic and sulfonic acid groups in the AGE gel. These sorption effects can be eliminated to the negligible level by prolonged deployment of DGT probes or by disassembling probes after the 1-2 days post-sampling period that is sufficient for release of uranium from diffusive gel and its sorption in resin gel.

  4. The substitution technique applied for determining the parameters of a reactor with void

    Energy Technology Data Exchange (ETDEWEB)

    Zdravkovic, Z; Ivkovic, M; Sotic, O [Institute of nuclear sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1965-12-15

    The material buckling of D{sub 2}O-enriched uranium (2% U{sub 235}) system with voided fuel assembly has been determined by means of the substitution technique. The experiments were carried out in the zero power reactor RB for various lattice pitches, namely: 11.3 cm, 14 cm, and 16 cm. As a reference core the D{sub 2}O-enriched uranium (2%U{sub 235}) ) system without voids has been used. The results have been analysed by the modified one-group perturbation theory using three regions in a substituted reactor (test, intermediate and reference). The perturbations in axial and radial directions due to voided fuel assembly, are also considered. In order to determine the change between diffusion coefficients in various regions ({delta}D), additional experiments with single test fuel element were made. The lattice pitches of reference and test regions were the same. According to the algorithms given in appendices, the programmes for the ZUSE Z-23 digital computer were made. These programmes include evaluations of the change between diffusion coefficients ({delta}D), and the axial buckling of the test lattice (author)

  5. Determination of sedimentation rates in Izmir Bay by 210Pb dating technique

    International Nuclear Information System (INIS)

    Ichedef, M.; Yener, G.; Ugur, A.; Oezden, B.; Goenuelalan, F.; Akoezcan, S.; Bueyuekisik, B.; Koeksal, E. Y.

    2006-01-01

    Environmental 2 10Pb (natural) dating technique was applied to determine sedimentation rates in Izmir Bay, near the heavily industrialized Turkish Coastal zone of the Aegean Sea. Core samples from different 20 stations in the inner bay were collected with core sampler and sedimentation rates were estimated from the vertical distribution of excess 2 10Pb. Core samples were stored for a period of 2-3 half-lives (9-14 months) of 2 10Po (t 1 /2=138 d) before analysis to allow build-up of 2 10Po from 2 10Pb. Po was collected on cupper disks by electrochemical deposition. Then, 2 10Pb activities were determined undirectly from 2 10Po activities. Measurement of 2 10Po were made through its 5.30 MeV alpha particle emission, using 2 09Po as the internal tracer. Measurements were made by PIPS (Passivated Implanted Planar Silicon) detector. The sedimentation rates for core samples analysed so far were calculated to vary from 0.198 cm y - 1 to 0.489 cm y - 1. The highest unsupported 2 10Pb concentrations (104 Bq kg - 1) were measured in the 8.station where the Ilica, Bayrakli and Bornova streams empty, and nearest to the harbour

  6. Detection and depth determination of corrosion defects in embedded bolts using ultrasonic testing technique

    International Nuclear Information System (INIS)

    Lin, Shan; Fukutomi, Hiroyuki; Yuya, Hideki; Ito, Keisuke

    2011-01-01

    A great number of anchor bolts are used to fix various components to concrete foundation in thermal and nuclear power plants. As aging power plants degrade, it is feared that defects resulted from corrosion may occur underground. In this paper, a measurement method utilizing the phased array technique is developed to detect such defects. Measurement results show that this method can detect local and circumferential corrosion defects introduced artificially, but defect echo position appears to be farther away from the bolt head than is actually the case. A finite element simulation of wave propagation shows that longitudinal waves excited by a phased array probe are mode converted and reflected at the defect and at bolt wall, which results in the position of the defect echo appearing to be farther away than the defect actually is. Moreover, an approach for determining the depth of defects using measurement results is also proposed based on numerical results. The depths determined by the proposed approach agree with the actual depths with a maximum error of 1.8 mm and a RMSE of 1.06 mm. (author)

  7. Chromium Fractions Changes Compared With Total-Cr As Determined by Neutron Activation Analysis Technique

    International Nuclear Information System (INIS)

    Abdel-Sabour, M.F.; Abdou, F.M.; Elwan, I.M.; Al-Salama, Y.J.

    2003-01-01

    Fifteen soil samples were chosen from different locations (five different locations at north greater Cairo, Egypt to represent different soils (alluvial and sandy) as well as different source of contaminated wastewater (sewage and industrial effluent). Using sequential extraction technique (extracting the soil with different solutions, which is designed to separate metal fractions), Cr was separated into six operationally defined fractions water soluble, exchangeable, carbonate bound, Fe-Mn oxides bound, organic bound and residual fractions. Result of soil total-Cr indicated the serious accumulation of Cr in soils subjected to prolonged irrigation with contaminated wastewater. As it could seen, total-Cr in the tested contaminated soils exceeds the permissible levels (75-100)ppm Cr by several order of magnitude particularly at the surface and subsurface layers. The highest accumulation of total Cr down to depth 60 cm was observed in case of soil E. Data showed that values of total Cr determined by NAA method were always higher than the relevant values determined either by AAS or those calculated after the sequential extraction method. T-test analysis showed the significant difference between NAA and either AAS or sequential extraction methods. Although T-test analysis showed that were significant differences between total content in soils as determined by destructive (AAS or SUM) and non-destructive (NAA) analytical techniques however, strong liner relation between NAA and other tested methods was obtained. Chromium distribution between different extractants shows that the greatest amounts are found in the residual and Occluded in Fe and Mn-Oxides fractions followed by carbonate or organic fractions. In most cases the proportion of all tested Cr-forms has increased in contaminated soil layers with higher enrichment in organically bound Cr, occluded in Fe and Mn oxides, carbonate exchangeable and soluble fractions. Results indicate that soil properties have a

  8. Construction of an experimental simplified model for determining of flow parameters in chemical reactors, using nuclear techniques

    International Nuclear Information System (INIS)

    Araujo Paiva, J.A. de.

    1981-03-01

    The development of a simplified experimental model for investigation of nuclear techniques to determine the solid phase parameters in gas-solid flows is presented. A method for the measurement of the solid phase residence time inside a chemical reactor of the type utilised in the cracking process of catalytic fluids is described. An appropriate radioactive labelling technique of the solid phase and the construction of an eletronic timing circuit were the principal stages in the definition of measurement technique. (Author) [pt

  9. Determination of Redistribution of Erosion/Deposition Rate in Cultivated Area Using 137Cs Technique

    International Nuclear Information System (INIS)

    Nita Suhartini; Syamsul Abbas RAS; Barokah A; Ali Arman L

    2004-01-01

    The aim of the research is to determine the rate of redistribution of erosion/deposition in cultivated area. The application of 137 Cs technique was carried out at cultivated area in Bojong - Ciawi, with slope less than 10 o and slope length of about 2 km. A reference site was selected at the top of the slope, and this site is flat, open and covered with grass. Two sites in the cultivated area were selected as study site namely LU-I ( 15 x 25 ) m with the distance of 1000 m from the top, and LU-II (17.5 x 20) m with the distance of 1300 m from the top. Sampling of soil at reference site was done by using scraper (20 x 50) cm, while sampling at study site by using core sampling (di = 7 cm). Soil samples were brought to the laboratorium for preparation and analysis of 137 Cs content. Preparation are including of drying, weighing the total dry, sieving and crushing. Analysis of 137 Cs content was done using multi channel analyzer (MCA) that connected to high purity germanium (HPGe), at 661 keV, and the minimum counting time of 16 hours. To estimate the erosion/deposit rate, two mathematical model were used, namely Proportional Model (PM) and Mass Balance Model 1 (MBM1). The result for application of 137 Cs technique showed that MBM1 gives somewhat higher value for deposit rate and somewhat lower value for erosion than PM. Land use - I (LU-I) of Bojong - Ciawi was suffering from erosion with the erosion rate from 1 t/(ha.y) to 13 t/(ha.y), and LU-II has deposit rate from 1 t/(ha.y) to 50 t/(ha.y). (author)

  10. Dual-isotope technique for determination of in vivo ketone body kinetics

    International Nuclear Information System (INIS)

    Miles, J.M.; Schwenk, W.F.; McClean, K.L.; Haymond, M.W.

    1986-01-01

    Total ketone body specific activity has been widely used in studies of ketone body metabolism to circumvent so-called isotope disequilibrium between the two major ketone body pools, acetoacetate and beta-hydroxybutyrate. Recently, this approach has been criticized on theoretical grounds. In the present studies, [13C]acetoacetate and beta-[14C]hydroxybutyrate were simultaneously infused in nine mongrel dogs before and during an infusion of either unlabeled sodium acetoacetate or unlabeled sodium beta-hydroxybutyrate. Ketone body turnover was determined using total ketone body specific activity, total ketone body moles % enrichment, and an open two-pool model, both before and during the exogenous infusion of unlabeled ketone bodies. Basal ketone body turnover rates were significantly higher using [13C]acetoacetate than with either beta-[14C]hydroxybutyrate alone or the dual-isotope model (3.6 +/- 0.5 vs. 2.2 +/- 0.2 and 2.7 +/- 0.2 mumol X kg-1 X min-1, respectively, P less than 0.05). During exogenous infusion of unlabeled sodium acetoacetate, the dual-isotope model provided the best estimate of ketone body inflow, whereas 14C specific activity underestimated the known rate of acetoacetate infusion by 55% (P less than 0.02). During sodium beta-hydroxybutyrate infusion, [13C]-acetoacetate overestimated ketone body inflow by 55% (P = NS), while better results were obtained with 14C beta-hydroxybutyrate alone and the two-pool model. Ketone body interconversion as estimated by the dual-isotope technique increased markedly during exogenous ketone body infusion. In conclusion, significant errors in estimation of ketone body inflow were made using single-isotope techniques, whereas a dual-isotope model provided reasonably accurate estimates of ketone body inflow during infusion of exogenous acetoacetate and beta-hydroxybutyrate

  11. Analytical techniques for determination of framework oxygen isotope ratio of wairakite

    International Nuclear Information System (INIS)

    Noto, Masami; Kusakabe, Minoru; Uchida, Tetsuo.

    1990-01-01

    Dehydration techniques were developed for the analysis of isotopic ratios of framework oxygen of wairakite, one of calcium zeolites often encountered in geothermal systems. Channel water in wairakite were separated from aluminosilicate framework by dehydration in vacuum at 300 deg, 400 deg, 450 deg, 500 deg, 550 deg, 650 deg, 750 deg, 850 deg, and 950 degC, and by stepwise heating at temperatures from 300 deg to 700 degC. The oxygen isotopic analyses of the separated channel water and the residual aluminosilicate framework of wairakite indicated that dehydration at temperatures higher than 400 degC is accompanied by isotopic exchang between the framework oxygen and dehydrating water vapor. The isotopic exchange during the high temperature dehydration makes the δ 18 O of framework oxygen lower and that of channel water higher than those obtained by dehydration at 300 degC. These results are consistent with dehydration behavior of wairakite under vacuum that the maximum rate of dehydration of channel water is attained at about 400 degC. Consequently it is recommended to dehydrate wairakite at a temperature as low as possible in order to avoid the effect of the isotopic exchange. Time required to attain complete dehydration becomes longer with lowering the temperature of dehydration. To compromise these conflicting effects, the optimum conditions of dehydration have been found that most of the channel water is dehydrated at 300 degC for 24 hours, followed by stepwise heating for additional 17 hours up to 700 degC. We obtained a better than ± 0.1 reproducibility for the framework oxygen isotopic determinations with this technique. (author)

  12. The Achilles Heel of Normal Determinations via Minimum Variance Techniques: Worldline Dependencies

    Science.gov (United States)

    Ma, Z.; Scudder, J. D.; Omidi, N.

    2002-12-01

    Time series of data collected across current layers are usually organized by divining coordinate transformations (as from minimum variance) that permits a geometrical interpretation for the data collected. Almost without exception the current layer geometry is inferred by supposing that the current carrying layer is locally planar. Only after this geometry is ``determined'' can the various quantities predicted by theory calculated. The precision of reconnection rated ``measured'' and the quantitative support for or against component reconnection be evaluated. This paper defines worldline traversals across fully resolved Hall two fluid models of reconnecting current sheets (with varying sizes of guide fields) and across a 2-D hybrid solution of a super critical shock layer. Along each worldline various variance techniques are used to infer current sheet normals based on the data observed along this worldline alone. We then contrast these inferred normals with those known from the overview of the fully resolved spatial pictures of the layer. Absolute errors of 20 degrees in the normal are quite commonplace, but errors of 40-90 deg are also implied, especially for worldlines that make more and more oblique angles to the true current sheet normal. These mistaken ``inferences'' are traceable to the degree that the data collected sample 2-D variations within these layers or not. While it is not surprising that these variance techniques give incorrect errors in the presence of layers that possess 2-D variations, it is illuminating that such large errors need not be signalled by the traditional error formulae for the error cones on normals that have been previously used to estimate the errors of normal choices. Frequently the absolute errors that depend on worldline path can be 10 times the random error that formulae would predict based on eigenvalues of the covariance matrix. A given time series cannot be associated in any a priori way with a specific worldline

  13. Determination of in-depth contamination in concrete using a non-destructive technique

    International Nuclear Information System (INIS)

    Boden, S.; Cantrel, E.

    2007-01-01

    The decommissioning of the BR3 (Belgian Reactor 3) approaches its final phase, in which the building structures are being decontaminated and either denuclearized for possible reuse or demolished. Apart from the presence of naturally occurring radionuclides in building materials, other radionuclides might be present due to activation or contamination. The BR3 bioshield has been exposed to rather high neutron leakage fluxes during the reactor operation and is therefore activated. Building structure contamination usually results from leakages during reactor operation, releases due to maintenance works or even dismantling operations. In case of in-depth contamination in concrete it is important to know the exact in-depth profile before decontamination, in order to minimize the amount of radioactive waste that will be produced during the decontamination process and to optimize both the decontamination process and the final control measurements. Common non-destructive analyses used in decommissioning are usually based on the measurement of beta radiation, using e.g. hand-held plastic scintillators. This kind of measurement technique can not be used to determine in-depth contamination. Therefore, most of the decontamination specialists currently base themselves on the results of the radiological analysis of samples taken by core drilling. The use of such a destructive method implies a number of disadvantages: it is time consuming and therefore costly and the different sample preparation steps can conceivably lead to cross-contamination. Moreover, one only receives results of a limited number of points, while the in-depth contamination is usually very inhomogeneously distributed and the relationship between in-depth contamination and surface contamination and/or dose rate (hotspot detection) is generally rather poor.The objective therefore is to test the use of the ISOCS (In Situ Object Counting System) for the determination of contamination depth

  14. New technique for the determination of trace noble metal content in geological and process materials

    Energy Technology Data Exchange (ETDEWEB)

    Mitkin, V.N. E-mail: mit@che.nsk.su; Zayakina, S.B.; Anoshin, G.N

    2003-02-03

    A new two-step sample preparation technique is proposed for the instrumental determination of trace quantities of noble metals (NM) in refractory geological and process materials. The decomposition procedure is based on the oxidizing fluorination of samples with subsequent sulfatization (OFS) of the sample melt or cake. Fluorination of samples is accomplished using a mixture of KHF{sub 2}+KBrF{sub 4} or KHF{sub 2}+BrF{sub 3} depending on the ratio of sample mass to oxidizing mixture. Both cakes and melts can result using this procedure. Sulfatization of resulting fluorides is completed using concentrated sulfuric acid heated to 550 deg. C. Validation studies using certified geostandard reference materials (GSO VP-2, ZH-3, Matte RTP, HO-1, SARM-7) have shown that the proposed method is fast, convenient and most often produces non-hygroscopic homogeneous residues suitable for analysis by atomic absorption spectrometry (AAS) and atomic emission spectrometry (AES). Results obtained for NM concentrations in reference materials agreed with certified concentration ranges and results obtained using other methods of analysis. The OFS procedure combined with direct current plasma d.c. plasma AES achieved the following limits of detection (LOD) for the noble metals: Ag, Au, Pd, 1-2x10{sup -6}; Pt, 5x10{sup -6}; and Ru, Rh, Ir, Os, 1-3x10{sup -7} wt.%. Using graphite furnace AAS (GFAAS) combined extraction pre-concentration the following LODs for NMs were achieved: Pt, Ru, 1x10{sup -6}; Pd, Rh, 1x10{sup -7}; and Au, Ag, 1-2x10{sup -8} wt.%. The relative standard deviation for NM determinations (S{sub r}) was dependent on NM concentration and sample type, but commonly was in the range of 3-15% for d.c. plasma AES and 5-30% for GFAAS.

  15. Plasma-based techniques applied to the determination of metals and metalloids in atmospheric aerosols

    International Nuclear Information System (INIS)

    Smichowski, Patricia

    2011-01-01

    Full text: This lecture presents an overview of the research carried out by our group during the last decade on the determination of metals, metalloids, ions and species in atmospheric aerosols and related matrices using plasma-based techniques. In our first studies we explored the application of a size fractionation procedure and the subsequent determination of minor, major and trace elements in samples of deposited particles collected one day after the eruption of the Copahue Volcano, located in the Chile-Argentina border to assess the content of relevant elements with respect of the environment and the local population health. We employed a multi-technique approach (ICP-MS, XRD and NAA) to gain complete information of the characteristics of the sample. In addition to the study of ashes emitted for natural sources we also studied ashes of anthropogenic origin such as those arising from coal combustion in thermal power plants. For estimating the behavior and fate of elements in atmospheric particles and ashes we applied in this case a chemical fractionation procedure in order to establish the distribution of many elements amongst soluble, bound to carbonates, bound to oxides and bound to organic matter and environmental immobile fraction. Studies on the air quality of the mega-city of Buenos Aires were scarce and fragmentary and our objective was, and still is, to contribute to clarify key issues related to levels of crustal, toxic and potentially toxic elements in this air basin. Our findings were compared with average concentrations of metals and metalloids with results reported for other Latin American cities such as Sao Paulo, Mexico and Santiago de Chile. In this context, a series of studies were carried out since 2004 considering different sampling strategies to reflect local aspects of air pollution sources. In the last years, our interest was focused on the levels of traffic-related elements in the urban atmosphere. We have contributed with the first data

  16. Plasma-based techniques applied to the determination of metals and metalloids in atmospheric aerosols

    Energy Technology Data Exchange (ETDEWEB)

    Smichowski, Patricia, E-mail: smichows@cnea.gov.ar [Comision Nacional de Energia Atomica, Gerencia Quimica, Pcia de Buenos Aires (Argentina)

    2011-07-01

    Full text: This lecture presents an overview of the research carried out by our group during the last decade on the determination of metals, metalloids, ions and species in atmospheric aerosols and related matrices using plasma-based techniques. In our first studies we explored the application of a size fractionation procedure and the subsequent determination of minor, major and trace elements in samples of deposited particles collected one day after the eruption of the Copahue Volcano, located in the Chile-Argentina border to assess the content of relevant elements with respect of the environment and the local population health. We employed a multi-technique approach (ICP-MS, XRD and NAA) to gain complete information of the characteristics of the sample. In addition to the study of ashes emitted for natural sources we also studied ashes of anthropogenic origin such as those arising from coal combustion in thermal power plants. For estimating the behavior and fate of elements in atmospheric particles and ashes we applied in this case a chemical fractionation procedure in order to establish the distribution of many elements amongst soluble, bound to carbonates, bound to oxides and bound to organic matter and environmental immobile fraction. Studies on the air quality of the mega-city of Buenos Aires were scarce and fragmentary and our objective was, and still is, to contribute to clarify key issues related to levels of crustal, toxic and potentially toxic elements in this air basin. Our findings were compared with average concentrations of metals and metalloids with results reported for other Latin American cities such as Sao Paulo, Mexico and Santiago de Chile. In this context, a series of studies were carried out since 2004 considering different sampling strategies to reflect local aspects of air pollution sources. In the last years, our interest was focused on the levels of traffic-related elements in the urban atmosphere. We have contributed with the first data

  17. Determination of elemental in soil samples from Gebeng area using NAA technique

    International Nuclear Information System (INIS)

    Md Suhaimi Elias; Wo, Y.M.; Mohd Suhaimi Hamzah

    2016-01-01

    Rapid development and urbanization will increase number of residence and industrial area. Without proper management and control of pollution, these will give an adverse effect to environment and human life. The objective of this study to identify and quantify key contaminants into the environment of the Gebeng area as a result of industrial and human activities. Gebeng area was gazetted as one of the industrial estate in Pahang state. Assessment of elemental pollution in soil of Gebeng area base on level of concentration, enrichment factor and geo-accumulation index. The enrichment factors (EFs) were determined by the elemental rationing method, whilst the geo-accumulation index (I_g_e_o) by comparing of current to continental crustal average concentration of element. Twenty-seven of soil samples were collected from Gebeng area. Soil samples were analysed by using Neutron Activation Analyses (NAA) technique. The obtained data showed higher concentration of iron (Fe) due to abundance in soil compared to other elements. The results of enrichment factor showed that Gebeng area have enrich with elements of As, Br, Hf, Sb, Th and U. Base on the geo-accumulation index (I_g_e_o) classification, the soil quality of Gebeng area can be classified as class 0, (uncontaminated) to Class 3, (moderately to heavily contaminated). (author)

  18. The Comparison Study of Neutron Activation Analysis and Fission Track Technique for Uranium Determination

    International Nuclear Information System (INIS)

    Sirinuntavid, Alice; Rodthongkom, Chouvana

    2007-08-01

    Full text: Comparison between Neutron Activation Analysis (NAA) and fission track technique for uranium determination in solid samples was studied by use of standard reference materials, i.e., ore, coal fly ash, soil. For NAA, the epithermal neutron was applied for activated irradiation. Then, the 74.5 keV gamma from U-239 or 277.7 keV gamma from Np-239 was measured. For high Uranium content samples, NAA method with 74.5 keV gamma measurement, gave higher precision result than the 277.7 keV gamma measurement method. NAA method with 277.7 keV gamma measurement, gave higher sensitivity and precision result for low Uranium content samples and the uranium contained less than 10 ppm samples. Nevertheless, the latter procedure needed longer time for neutron irradiation and analysis procedure. In comparison the results of Uranium analysis between NAA and fission track, it was found that no significant difference within 95 % of confidence level

  19. Determination of organically bound Tritium in environmental samples by application of the oxidizing plasma technique

    International Nuclear Information System (INIS)

    Strack, S.; Koenig, L.A.

    1981-12-01

    The low-temperature oxidizing plasma technique with a suitable system for trapping the water formed in the oxidation process can be used to determine T bound organically in low-level samples. First, the samples are freeze-dried and the tissue water obtained in this way is measured, after distillation, in a liquid scintillation spectrometer. The residual dry matter is ashed in the reactor chamber of the plasma system. Oxidation takes place at temperatures not exceeding 200 0 C in an oxygen flow of about 40 ml/min. The water of oxidation is collected in a cold trap installed behind the reactor chamber. A volume of about 10 ml of water is sufficient to measure the tritium activity without enrichment. The oxidation behavior of various organic materials has been tested. Some first results of T concentrations in tissue water and the organic dry matter from food and plant samples collected in the vicinity of the Nuclear Research Center are presented. The method has the advantage that a commercially available instrument can be used requiring only little additional equipment. Handling is much less dangerous and contamination effects by atmospheric T can be easily kept at a minimum. (orig./HP) [de

  20. Determination of Potential Fishing Grounds of Rastrelliger kanagurta Using Satellite Remote Sensing and GIS Technique

    International Nuclear Information System (INIS)

    Suhartono Nurdin; Muzzneena Ahmad Mustapha; Tukimat Lihan; Mazlan Abdul Ghaffar; Muzzneena Ahmad Mustapha; Nurdin, S.

    2015-01-01

    Analysis of relationship between sea surface temperature (SST) and Chlorophyll-a (chl-a) improves our understanding on the variability and productivity of the marine environment, which is important for exploring fishery resources. Monthly level 3 and daily level 1 images of Moderate Resolution Imaging Spectroradiometer Satellite (MODIS) derived SST and chl-a from July 2002 to June 2011 around the archipelagic waters of Spermonde Indonesia were used to investigate the relationship between SST and chl-a and to forecast the potential fishing ground of Rastrelliger kanagurta. The results indicated that there was positive correlation between SST and chl-a (R=0.3, p<0.05). Positive correlation was also found between SST and chl-a with the catch of R. kanagurta (R=0.7, p<0.05). The potential fishing grounds of R. kanagurta were found located along the coast (at accuracy of 76.9 %). This study indicated that, with the integration of remote sensing technology, statistical modeling and geographic information systems (GIS) technique were able to determine the relationship between SST and chl-a and also able to forecast aggregation of R. kanagurta. This may contribute in decision making and reducing search hunting time and cost in fishing activities. (author)

  1. DETERMINING INDICATORS OF URBAN HOUSEHOLD WATER CONSUMPTION THROUGH MULTIVARIATE STATISTICAL TECHNIQUES

    Directory of Open Access Journals (Sweden)

    Gledsneli Maria Lima Lins

    2010-12-01

    Full Text Available Water has a decisive influence on populations’ life quality – specifically in areas like urban supply, drainage, and effluents treatment – due to its sound impact over public health. Water rational use constitutes the greatest challenge faced by water demand management, mainly with regard to urban household water consumption. This makes it important to develop researches to assist water managers and public policy-makers in planning and formulating water demand measures which may allow urban water rational use to be met. This work utilized the multivariate techniques Factor Analysis and Multiple Linear Regression Analysis – in order to determine the participation level of socioeconomic and climatic variables in monthly urban household consumption changes – applying them to two districts of Campina Grande city (State of Paraíba, Brazil. The districts were chosen based on socioeconomic criterion (income level so as to evaluate their water consumer’s behavior. A 9-year monthly data series (from year 2000 up to 2008 was utilized, comprising family income, water tariff, and quantity of household connections (economies – as socioeconomic variables – and average temperature and precipitation, as climatic variables. For both the selected districts of Campina Grande city, the obtained results point out the variables “water tariff” and “family income” as indicators of these district’s household consumption.

  2. Evaluating chemical extraction techniques for the determination of uranium oxidation state in reduced aquifer sediments

    Science.gov (United States)

    Stoliker, Deborah L.; Campbell, Kate M.; Fox, Patricia M.; Singer, David M.; Kaviani, Nazila; Carey, Minna; Peck, Nicole E.; Barger, John R.; Kent, Douglas B.; Davis, James A.

    2013-01-01

    Extraction techniques utilizing high pH and (bi)carbonate concentrations were evaluated for their efficacy in determining the oxidation state of uranium (U) in reduced sediments collected from Rifle, CO. Differences in dissolved concentrations between oxic and anoxic extractions have been proposed as a means to quantify the U(VI) and U(IV) content of sediments. An additional step was added to anoxic extractions using a strong anion exchange resin to separate dissolved U(IV) and U(VI). X-ray spectroscopy showed that U(IV) in the sediments was present as polymerized precipitates similar to uraninite and/or less ordered U(IV), referred to as non-uraninite U(IV) species associated with biomass (NUSAB). Extractions of sediment containing both uraninite and NUSAB displayed higher dissolved uranium concentrations under oxic than anoxic conditions while extractions of sediment dominated by NUSAB resulted in identical dissolved U concentrations. Dissolved U(IV) was rapidly oxidized under anoxic conditions in all experiments. Uraninite reacted minimally under anoxic conditions but thermodynamic calculations show that its propensity to oxidize is sensitive to solution chemistry and sediment mineralogy. A universal method for quantification of U(IV) and U(VI) in sediments has not yet been developed but the chemical extractions, when combined with solid-phase characterization, have a narrow range of applicability for sediments without U(VI).

  3. A comparison of various modes of liquid-liquid based microextraction techniques: determination of picric acid.

    Science.gov (United States)

    Burdel, Martin; Šandrejová, Jana; Balogh, Ioseph S; Vishnikin, Andriy; Andruch, Vasil

    2013-03-01

    Three modes of liquid-liquid based microextraction techniques--namely auxiliary solvent-assisted dispersive liquid-liquid microextraction, auxiliary solvent-assisted dispersive liquid-liquid microextraction with low-solvent consumption, and ultrasound-assisted emulsification microextraction--were compared. Picric acid was used as the model analyte. The determination is based on the reaction of picric acid with Astra Phloxine reagent to produce an ion associate easily extractable by various organic solvents, followed by spectrophotometric detection at 558 nm. Each of the compared procedures has both advantages and disadvantages. The main benefit of ultrasound-assisted emulsification microextraction is that no hazardous chlorinated extraction solvents and no dispersive solvent are necessary. Therefore, this procedure was selected for validation. Under optimized experimental conditions (pH 3, 7 × 10(-5) mol/L of Astra Phloxine, and 100 μL of toluene), the calibration plot was linear in the range of 0.02-0.14 mg/L and the LOD was 7 μg/L of picric acid. The developed procedure was applied to the analysis of spiked water samples. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Determining nutrients degradation kinetics of chickpea (Cicer arietinum straw using nylon bag technique in sheep

    Directory of Open Access Journals (Sweden)

    A. Mirzaei-Aghsaghali

    2012-05-01

    Full Text Available Straw a by-product from grain legume crops is produced in large quantities in Iran. Straw is constant component of ruminant diets on small holder farms; however, there is little information about its nutritive value. Accordingly experiment was conducted to determine the chemical composition and ruminal organic matter (OM and crude protein (CP degradability of chickpea straw using nylon bags (in situ technique. Replicated samples were incubated at 0, 2, 4, 8, 12, 24, 48 and 72 hours in three rumen canulated Ghezel rams with 50±3 kg body weight. Dry matter (DM, CP, ether extract (EE, OM, crude fiber (CF and nitrogen free extract (NFE content of chickpea straws were 92.2, 6.1, 5.5, 92.0, 34.3 and 46.2%, respectively. The soluble fraction (a of the OM and CP of chickpea straw was 17.5 and 40.8% and potential degradability (a+b of OM and CP was 56.7 and 72.0%, respectively. Effective degradability at different passage rates (2, 5 and 8% per hours for OM was 51.0 44.9 and 40.7% and for CP were 68.4, 64.3 and 61.3%, respectively. In conclusion, based on chemical composition and degradation characteristics, chickpea straw could have moderate nutritive value for ruminants.

  5. Determination of the catalyst circulation rate in a FCC cold flow pilot unit using nuclear techniques

    International Nuclear Information System (INIS)

    Santos, Valdemir A. dos; Lima, Emerson A.O.

    2013-01-01

    Nuclear techniques of gamma transmission and radioactive tracer were used to estimate the catalyst circulation rate in a cold flow pilot plant unit of Fluid Catalytic Cracking (FCC). Catalyst circulation rate in a FCC unit, allow to determine operating conditions of the exchange catalyst and inlet data for fluid dynamic simulation computational program. The pilot unit was fabricated obeying geometrical parameters provided by the Petrobras Research Center (CENPES), based on hot pilot units to existing in that center. The cold flow pilot unit has a transfer line, two separation vessels flash type, a return column, a riser and a regenerator. The vertical sections as riser, return column, regenerator column and transfer line are made of transparent material (glass). The two separation vessels have bases with tapered cylindrical shapes and are made of steel plates. The riser is divided into four sections of different diameters (0.005 m, 0.010 m, 0.018 m and 0.025 m) and rising upwards, to simulate the increasing flow rate caused by the increase of volume with the increase of the number of moles due to molecules breakage. The radioactive tracer used was the catalyst itself (intrinsic tracer) irradiated by neutron activation, yielding the radioisotope 59 Fe. The velocity measurements were also obtained with aid of an electronic clock triggered by certain radiation levels across the two detectors. Besides estimates for the catalyst circulation rate was possible to identify the type of flow relative to the catalyst in return column. (author)

  6. Development of the fission fragment track registration technique for the determination of the uranium contamination

    International Nuclear Information System (INIS)

    Tanaka, E.M.

    1979-01-01

    The Fission Fragment Track Registration Technique is developed to measure the uranium concentration about microgram of uranium per litre of liquid samples. The drying method of drops on the detector (Makrofol KG) and a special sampling procedure to avoid the cumbersome high density of tracks formation at the edge of the deposition surface as a 'ring' is adopted. The samples are irradiated by neutrons produced by the IEA-R1 Reactor (thermal neutron flux about 10 12 neutrons/cm 2 .s) inducing the uranium fission. The tracks registered by the fission fragments in the detector are chemically enlarged and counted by an automatic couting system. By this method the uranium concentrations ranging from 0,9 to 7,6 microgram of uranium per litre, can be determined with precisions between 2,7% the greater and 23% to the lower concentration. The uranium concentration measurements in human hair and urine are made showing that this method is very useful to control and detect eventual uranium contamination [pt

  7. Quality control on pre-serial Bridgman production of PbWO{sub 4} scintillating crystals by means of photoelasticity

    Energy Technology Data Exchange (ETDEWEB)

    Rinaldi, D., E-mail: d.rinaldi@univpm.i [Dipartimento di Fisica e Ingegneria dei Materiali e del Territorio, Universita Politecnica delle Marche, via Brecce Bianche, 60131 Ancona (Italy); INFN section of Perugia (Italy); Ciriaco, A. [Dipartimento di Fisica e Ingegneria dei Materiali e del Territorio, Universita' Politecnica delle Marche, via Brecce Bianche, 60131 Ancona (Italy); Lebeau, M. [CERN PH department, 1211 Geneva 23 (Switzerland); Paone, N. [Dipartimento di Meccanica, Universita' Politecnica delle Marche, via Brecce Bianche, 60131 Ancona (Italy)

    2010-04-11

    Residual internal stresses in PbWO{sub 4} (PWO) scintillating crystals grown by Bridgman method have been systematically studied. Residual stresses induced during growth play an important role in production yield. Cracking probability during mechanical processing as well as stable mechanical properties in finished crystal are closely related to internal stress levels. A regular production of good-quality crystals requires a fast and easy feed-back on growth parameters. Samples from a pre-serial production were analyzed in order to give the producer a quality feed-back for process optimization. By means of photoelasticity, we measured residual stress distribution in several sections along the growth axis and for typical positions in every section. The stress analysis revealed defects occurring during the crystallization process, attributed to dislocations, lattice disorientation and poly-crystallinity. This work had been prompted by the need for quality monitoring of a pre-serial production of PWO for the CMS experiment at CERN's LHC. Mapping stress levels inside the ingot volume and proposing a synthetic parameter to be used as a quality indicator, the resulting analysis should contribute to parameter optimization and improve the growth performance. The proposed method may be useful in conventional crystal production.

  8. N and Si Implantation Effect on Structural and Electrical Properties of Bridgman grown GaSe Single Crystal

    International Nuclear Information System (INIS)

    Karabulut, O.

    2004-01-01

    N and Si implantation to GaSe single crystals were carried out parallel to c-axis with ion beam of about 10 1 6 ions/cm 2 dose having energy values 30, 60 and 100 keV. Ion implantation modifications on Bridgman grown GaSe single crystals have been investigated by means of XRD, electrical conductivity, absorption and photoconductivity measurements. XRD measurements revealed that annealing results in a complete recovery of the crystalline nature that was moderately reduced upon implantation. It was observed that both N- and Siimplantation followed by annealing process decreased the resistivity values from 10 7 to 10 3 .-cm. The analysis of temperature dependent conductivity showed that at high temperature region above 200 K, the transport mechanism is dominated by thermal excitation in the doped and undoped GaSe samples. At lower temperatures, the conduction of carriers is dominated by variable range hopping mechanism in the implanted samples. Absorption and spectral photoconductivity measurements showed that the band edge is shifted in the implanted sample. All these modifications were attributed to the structural modifications and continuous shallow trap levels introduced upon implantation and annealing

  9. Determination of lead in clay enameled by X-ray fluorescence technique in Total reflection and by Scanning Electron Microscopy

    International Nuclear Information System (INIS)

    Zarazua O, G.; Carapia M, L.

    2000-01-01

    This work has the objective of determining lead free in the glazed commercial stewing pans using the X-ray fluorescence technique in Total reflection (FRX) and the observation and semiquantitative determination of lead by Analytical Scanning Electron Microscopy (ASEM). (Author)

  10. Non-interferometric determination of optical anisotropy in highly-oriented fibres using transport intensity equation technique

    Science.gov (United States)

    Sokkar, T. Z. N.; El-Farahaty, K. A.; El-Bakary, M. A.; Raslan, M. I.; Omar, E. Z.; Hamza, A. A.

    2018-03-01

    The optical setup of the transport intensity equation (TIE) technique is developed to be valid for measuring the optical properties of the highly-oriented anisotropic fibres. This development is based on the microstructure models of the highly-oriented anisotropic fibres and the principle of anisotropy. We provide the setup of TIE technique with polarizer which is controlled via stepper motor. This developed technique is used to investigate the refractive indices in the parallel and perpendicular polarization directions of light for the highly-oriented poly (ethylene terephthalate) (PET) fibres and hence its birefringence. The obtained results through the developed TIE technique for PET fibre are compared with that determined experimentally using the Mach-Zehnder interferometer under the same conditions. The comparison shows a good agreement between the obtained results from the developed technique and that obtained from the Mach-Zehnder interferometer technique.

  11. Development of analytical techniques for determining rare earth elements in geological materials

    International Nuclear Information System (INIS)

    Moraes, Noemia M.P. de; Kakazu, M.H.; Iyer, S.S.

    1987-01-01

    This work presents a comparative study between instrumental neutron activation analysis, inductively coupled plasma emission spectrometry and mass spectrometric isotope dilution techniques. Some advantages and disadvantages of the techniques are presented, depending on the type of the analysis required. Emphasis in give upon mass spectrometric isotope dilution, and some procedures for the development of this technique are presented. This methodology is being established by the nuclear and isotopic geology group of the IPEN. (author) [pt

  12. A new technique for thick source alpha counting determination of U and Th

    CERN Document Server

    Michael, C T

    2000-01-01

    A new technique for the calculation of U and Th concentration is presented based on the alpha particle spectrum taken from a thick sample by using a silicon detector. Four approaches to the analysis of the experimental data are presented, one being an improvement on the known pairs technique. By the proposed technique it is possible to calculate the concentrations of certain daughter nuclides in the two series, or the sum of the activity concentrations of others. This allows the detection of secular disequilibrium in our samples. This technique also has the advantage of being more accurate and provides the opportunity to cross-check the results derived from the different approaches.

  13. Determination of long-lived radionuclides at ultratrace level using advanced mass spectrometric techniques

    International Nuclear Information System (INIS)

    Zoriy, M.

    2005-11-01

    Determination of long-lived radionuclides at sub-fg concentration level is a challenging task in analytical chemistry. Inductively coupled plasma mass spectrometry (ICP-MS) with its ability to provide the sensitive and fast multielemental analysis is one of the most suitable method for the measurements of long lived radionuclides in the trace and ultra trace concentration range. In present the Ph.D. study a variety of procedures have been developed permitting the sub fg ml-1 determination of long-lived radionuclides (e.g. U, Th, Pu) as well as 226 Ra (T 1/2 = 1600 y) and 90 Sr (T 1/2 = 28.1 y) in different samples. In order to avoid isobaric interferences, to increase the sensitivity, precision and accuracy of the methods the application of different techniques: pre-concentration of the sample, off-line separation on the crown resin, measurements under cold plasma conditions, using microconcentric nebulizers (e.g DIHEN, DS-5) or the application of LA-ICP-MS for sample introduction have been studied. The limits of detection for different radionuclides was significantly improved in comparison to the ones reported in the literature, and, depending on the method applied, was varied from 10 -15 to 10 -18 g ml -1 concentration range. In addition to the analysis of long lived radionuclides, some other elements, that can present potential interest to the analyzed sample, were measured within the framework of the present study. Laser ablation inductively coupled plasma mass spectrometry (LAICP- MS) was used to produce images of element distribution in 20μm m thin sections of human brain tissue. The sample surface was scanned (raster area ∝80 mm 2 ) with a focused laser beam (wavelength 213 nm, diameter of laser crater 50μm, and laser power density 3x10 9 W cm -2 ) in a cooled laser ablation chamber developed for these measurements. Cross sections of human brain samples - hippocampus as well as brain tissues infected and non-infected with Glioblastoma Multiforme (tumor

  14. Regression Techniques for Determining the Effective Impervious Area in Southern California Watersheds

    Science.gov (United States)

    Sultana, R.; Mroczek, M.; Dallman, S.; Sengupta, A.; Stein, E. D.

    2016-12-01

    The portion of the Total Impervious Area (TIA) that is hydraulically connected to the storm drainage network is called the Effective Impervious Area (EIA). The remaining fraction of impervious area, called the non-effective impervious area, drains onto pervious surfaces which do not contribute to runoff for smaller events. Using the TIA instead of EIA in models and calculations can lead to overestimates of runoff volumes peak discharges and oversizing of drainage system since it is assumed all impervious areas produce urban runoff that is directly connected to storm drains. This makes EIA a better predictor of actual runoff from urban catchments for hydraulic design of storm drain systems and modeling non-point source pollution. Compared to TIA, determining the EIA is considerably more difficult to calculate since it cannot be found by using remote sensing techniques, readily available EIA datasets, or aerial imagery interpretation alone. For this study, EIA percentages were calculated by two successive regression methods for five watersheds (with areas of 8.38 - 158mi2) located in Southern California using rainfall-runoff event data for the years 2004 - 2007. Runoff generated from the smaller storm events are considered to be emanating only from the effective impervious areas. Therefore, larger events that were considered to have runoff from both impervious and pervious surfaces were successively removed in the regression methods using a criterion of (1) 1mm and (2) a max (2 , 1mm) above the regression line. MSE is calculated from actual runoff and runoff predicted by the regression. Analysis of standard deviations showed that criterion of max (2 , 1mm) better fit the regression line and is the preferred method in predicting the EIA percentage. The estimated EIAs have shown to be approximately 78% to 43% of the TIA which shows use of EIA instead of TIA can have significant impact on the cost building urban hydraulic systems and stormwater capture devices.

  15. Application of neutron activation analysis technique in elemental determination of lichen samples

    International Nuclear Information System (INIS)

    Djoko Prakoso Dwi Atmodjo; Syukria Kurniawati; Woro Yatu Niken Syahfitri; Nana Suherman; Dadang Supriatna

    2010-01-01

    Lichen is one of the biological materials as pollution monitor that can give information about level, direction, and history of various pollutants in environment. Small sample weights and elemental content of lichens is on the order of ppm, so that its characterization requires advanced analytical techniques that has high sensitivity and capable of analyzing samples with weight of - 25 mg, such as neutron activation analysis. In this research, determination of elements was done in lichen samples obtained from Kiaracondong and Holis areas in Bandung city, to understanding the difference of industrial exposure level on surrounding environment. Samples were irradiated in RSG GA Siwabessy, Serpong, at 15 MW for 1-2 and 60 minutes for short irradiation and long irradiation, respectively. The samples were then counted using HPGe detector with GENIE 2000 software. The level of element in lichen for Kiaracondong area were Co, Cr, Cs, Fe, Mg, Mn, Sb, Sc, and V in the range of 0.55-0.86, 1.47-2.57, 0.87-1.19, 540-1005, 949-1674, 34.91-45.94, 0.08-0.14, 0.16-0.31, and ≤ 2.33 mg/kg, respectively, while for Holis area were 1.04-2.37, 4.41-10.36, 0.41-0.89, 3166-709, 1131-1422, 40.97-72.51, 0.33-0.50, 0.98-2.18, and 5.30-13.05 mg/kg respectively. From these results, it is known that pollution exposure from the semi industrial area Holis provide greater influence than in the semi industrial area Kiaracondong. (author)

  16. Determining plutonium mass in spent fuel with non-destructive assay techniques - NGSU research overview and update on 6 NDA techniques

    Energy Technology Data Exchange (ETDEWEB)

    Tobin, Stephen J [Los Alamos National Laboratory; Conlin, Jeremy L [Los Alamos National Laboratory; Evans, Louise G [Los Alamos National Laboratory; Hu, Jianwei [Los Alamos National Laboratory; Blanc, Pauline C [Los Alamos National Laboratory; Lafleur, Adrienne M [Los Alamos National Laboratory; Menlove, Howard O [Los Alamos National Laboratory; Schear, Melissa A [Los Alamos National Laboratory; Swinhoe, Martyn T [Los Alamos National Laboratory; Croft, Stephen [Los Alamos National Laboratory; Fensin, Michael L [Los Alamos National Laboratory; Freeman, Corey R [Los Alamos National Laboratory; Koehler, William E [Los Alamos National Laboratory; Mozin, V [Los Alamos National Laboratory; Sandoval, N P [Los Alamos National Laboratory; Lee, T H [KAERI; Cambell, L W [PNNL; Cheatham, J R [ORNL; Gesh, C J [PNNL; Hunt, A [IDAHO STATE UNIV; Ludewigt, B A [LBNL; Smith, L E [PNNL; Sterbentz, J [INL

    2010-09-15

    This poster is one of two complementary posters. The Next Generation Safeguards Initiative (NGSI) of the U.S. DOE has initiated a multi-lab/university collaboration to quantify the plutonium (Pu) mass in, and detect the diversion of pins from, spent nuclear fuel assemblies with non-destructive assay (NDA). This research effort has the goal of quantifying the capability of 14 NDA techniques as well as training a future generation of safeguards practitioners. By November of 2010, we will be 1.5 years into the first phase (2.5 years) of work. This first phase involves primarily Monte Carlo modelling while the second phase (also 2.5 years) will focus on experimental work. The goal of phase one is to quantify the detection capability of the various techniques for the benefit of safeguard technology developers, regulators, and policy makers as well as to determine what integrated techniques merit experimental work, We are considering a wide range of possible technologies since our research horizon is longer term than the focus of most regulator bodies. The capability of all of the NDA techniques will be determined for a library of 64 17 x 17 PWR assemblies [burnups (15, 30, 45, 60 GWd/tU), initial enrichments (2, 3, 4, 5%) and cooling times (1, 5, 20, 80 years)]. The burnup and cooling time were simulated with each fuel pin being comprised of four radial regions. In this paper an overview of the purpose will be given as well as a technical update on the following 6 neutron techniques: {sup 252}Cf Interrogation with Prompt Neutron Detection, Delayed Neutrons, Differential Die-Away, Differential Die-Away Self-Interrogation, Passive Neutron Albedo Reactivity, Self-Integration Neutron Resonance Densitometry. The technical update will quantify the anticipated performance of each technique for the 64 assemblies of the spent fuel library.

  17. Determining plutonium mass in spent fuel with non-destructive assay techniques - NGSI research overview and update on 6 NDA techniques

    International Nuclear Information System (INIS)

    Tobin, Stephen J.; Conlin, Jeremy L.; Evans, Louise G.; Hu, Kianwei; Blanc, P.C.; Lafleur, Am; Menlove, H.O.; Schear, M.A.; Swinhoe, M.T.; Croft, S.; Fensin, M.L.; Freeman, C.R.; Koehler, W.E.; Mozin, V.; Sandoval, N.P.; Lee, T.H.; Cambell, L.W.; Cheatham, J.R.; Gesh, C.J.; Hunt, A.; Ludewigt, B.A.; Smith, L.E.; Sterbentz, J.

    2010-01-01

    This poster is one of two complementary posters. The Next Generation Safeguards Initiative (NGSI) of the U.S. DOE has initiated a multi-lab/university collaboration to quantify the plutonium (Pu) mass in, and detect the diversion of pins from, spent nuclear fuel assemblies with non-destructive assay (NDA). This research effort has the goal of quantifying the capability of 14 NDA techniques as well as training a future generation of safeguards practitioners. By November of 2010, we will be 1.5 years into the first phase (2.5 years) of work. This first phase involves primarily Monte Carlo modelling while the second phase (also 2.5 years) will focus on experimental work. The goal of phase one is to quantify the detection capability of the various techniques for the benefit of safeguard technology developers, regulators, and policy makers as well as to determine what integrated techniques merit experimental work, We are considering a wide range of possible technologies since our research horizon is longer term than the focus of most regulator bodies. The capability of all of the NDA techniques will be determined for a library of 64 17 x 17 PWR assemblies (burnups (15, 30, 45, 60 GWd/tU), initial enrichments (2, 3, 4, 5%) and cooling times (1, 5, 20, 80 years)). The burnup and cooling time were simulated with each fuel pin being comprised of four radial regions. In this paper an overview of the purpose will be given as well as a technical update on the following 6 neutron techniques: 252 Cf Interrogation with Prompt Neutron Detection, Delayed Neutrons, Differential Die-Away, Differential Die-Away Self-Interrogation, Passive Neutron Albedo Reactivity, Self-Integration Neutron Resonance Densitometry. The technical update will quantify the anticipated performance of each technique for the 64 assemblies of the spent fuel library.

  18. Determination of structure of oriented samples using two-dimensional solid state NMR techniques

    International Nuclear Information System (INIS)

    Jin Hong; Harbison, G.S.

    1990-01-01

    One dimensional and two-dimensional MAS techniques can give detailed information about the structure and dynamics of oriented systems. We describe the application of such techniques to the liquid-crystalline polymer poly(p-phenyleneterphtalimide) (PPTA), and thence deduce the solid-state structure of the material. (author). 9 refs.; 6 figs

  19. Comparison of Techniques to Determine the Clearance of Ruminal Volatile Fatty Acids

    NARCIS (Netherlands)

    Resende Júnior, J.C.; Pereira, M.N.; Boer, H.; Tamminga, S.

    2006-01-01

    The objective of this experiment was to compare measurements of fractional clearance rates obtained by using an unlabeled valerate-CoEDTA technique with measurements obtained by using a 13C-labeled volatile fatty acids (VFA) technique. The exponential decay rate of the 13C/12C ratio after

  20. A technique for determining the depth distribution of cavities in He+-irradiated nickel

    International Nuclear Information System (INIS)

    Fenske, G.; Das, S.K.; Kaminsky, M.

    1979-01-01

    The authors describe a technique for examining the depth distribution of the damage (i.e., dislocations, bubbles and voids) in 4 He + ion-irradiated nickel. One existing technique is to section the sample parallel to the direction of the incident beam and prepare thin foils suitable for TEM. This technique has been used only in a few instances because of the difficulty in sample preparation, but it has the advantage that the entire depth distribution of damage can be obtained from a single sample. The technique described by the present authors is a modification of this type of technique and allows one to observe the depth distribution of bubbles and of damage in very near surface regions (<0.2μm) with excellent depth resolution and a small (approximately 50 A) uncertainty in locating the irradiated surface. (Auth.)

  1. Sensitivity Analysis of Electromagnetic Induction Technique to Determine Soil Salinity in Large –Scale

    Directory of Open Access Journals (Sweden)

    Yousef Hasheminejhad

    2017-02-01

    Full Text Available Introduction: Monitoring and management of saline soils depends on exact and updatable measurements of soil electrical conductivity. Large scale direct measurements are not only expensive but also time consuming. Therefore application of near ground surface sensors could be considered as acceptable time- and cost-saving methods with high accuracy in soil salinity detection. . One of these relatively innovative methods is electromagnetic induction technique. Apparent soil electrical conductivity measurement by electromagnetic induction technique is affected by several key properties of soils including soil moisture and clay content. Materials and Methods: Soil salinity and apparent soil electrical conductivity data of two years of 50000 ha area in Sabzevar- Davarzan plain were used to evaluate the sensitivity of electromagnetic induction to soil moisture and clay content. Locations of the sampling points were determined by the Latin Hypercube Sampling strategy, based on 100 sampling points were selected for the first year and 25 sampling points for the second year. Regarding to difficulties in finding and sampling the points 97 sampling points were found in the area for the first year out of which 82 points were sampled down to 90 cm depth in 30 cm intervals and all of them were measured with electromagnetic induction device at horizontal orientation. The first year data were used for training the model which included 82 points measurement of bulk conductivity and laboratory determination of electrical conductivity of saturated extract, soil texture and moisture content in soil samples. On the other hand, the second year data which were used for testing the model integrated by 25 sampling points and 9 bulk conductivity measurements around each point. Electrical conductivity of saturated extract was just measured as the only parameter in the laboratory for the second year samples. Results and Discussion: Results of the first year showed a

  2. Primary study on image addition technique in CT measuring used to determine the malalignment of patellofemoral joints

    International Nuclear Information System (INIS)

    Huan Jian; Gong Jianping; Zhu Jianbing; Dong Qirong; Lu Zhian

    2000-01-01

    Objective: To evaluate the use of image addition technique in the field of CT measuring on patellofemoral joints. Method: In contractive condition and relaxant condition of quadriceps, 60 knee joints of 30 patients (47 knee joints accompanied with peri-patellar pain) were examined by CT scanning, and the CT image addition and single technique. Results: In contractive and relaxant condition of quadriceps in the normal group, the difference between index measured by image addition technique were not significant and it was found that demonstrated measurement error of image addition was smaller, but there was significant difference between index measured by single technique, and it suggests that its replication was bad. Conclusion: Use of image addition technique can decrease measurement error and play a important role on accurately determining the malalignment of patellofemoral joints

  3. The extraction and chromatographic determination of the essentials oils from Ocimum basilicum L. by different techniques

    Energy Technology Data Exchange (ETDEWEB)

    Soran, Maria Loredana; Varodi, Codruta; Lung, Ildiko; Surducan, Emanoil; Surducan, Vasile [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath, 400293 Cluj-Napoca (Romania); Cobzac, Simona Codruta, E-mail: loredana.soran@itim-cj.r [Babes-Bolyai University, Faculty of Chemistry and Chemical Engineering, 11 Arany Janos, 400028 Cluj-Napoca (Romania)

    2009-08-01

    Three different techniques (maceration, sonication and extraction in microwave field) were used for extraction of essential oils from Ocimum basilicum L. The extracts were analyzed by TLC/HPTLC technique and the fingerprint informations were obtained. The GC-FID was used to characterized the extraction efficiency and for identify the terpenic bioactive compounds. The most efficient extraction technique was maceration followed by microwave and ultrasound. The best extraction solvent system was ethyl ether + ethanol (1:1, v/v). The main compounds identified in Ocimum basilicum L. extracts were: {alpha} and {beta}-pinene (mixture), limonene, citronellol, and geraniol.

  4. The extraction and chromatographic determination of the essentials oils from Ocimum basilicum L. by different techniques

    International Nuclear Information System (INIS)

    Soran, Maria Loredana; Varodi, Codruta; Lung, Ildiko; Surducan, Emanoil; Surducan, Vasile; Cobzac, Simona Codruta

    2009-01-01

    Three different techniques (maceration, sonication and extraction in microwave field) were used for extraction of essential oils from Ocimum basilicum L. The extracts were analyzed by TLC/HPTLC technique and the fingerprint informations were obtained. The GC-FID was used to characterized the extraction efficiency and for identify the terpenic bioactive compounds. The most efficient extraction technique was maceration followed by microwave and ultrasound. The best extraction solvent system was ethyl ether + ethanol (1:1, v/v). The main compounds identified in Ocimum basilicum L. extracts were: α and β-pinene (mixture), limonene, citronellol, and geraniol.

  5. Analysis of Pricing Techniques in Determining a Fair and Reasonable Price

    National Research Council Canada - National Science Library

    Redman, Kevin

    1998-01-01

    The purpose of this thesis is to idenfity the principal techniques used by firms in pricing products for sale to the Government and to examine and analyze the conditions contributing to a firm's pricing strategy...

  6. Determination of radon exhalation rates from tiles using active and passive techniques

    International Nuclear Information System (INIS)

    Al-Jarallah, M.I.; Abu-Jarad, F.; Fazal-ur-Rehman

    2001-01-01

    Measurements of radon exhalation rates for selected samples of tiles used in Saudi Arabia were carried out using active and passive measuring techniques. These samples were granite, marble and ceramic. In the active method, a PC-based radon gas analyzer with emanation container was used, while, in the passive method, PM-355 nuclear track detectors with the 'can technique' were applied for 180 days. A comparison of the exhalation rates measured by the two techniques showed a good linear correlation coefficient of 0.7. The granite samples showed an average radon exhalation rate of 0.7 Bq m -2 h -1 , which was higher than that of marble and ceramic by more than twofold. The radon exhalation rates measured by the 'can technique' showed a non-uniform exhalation from the surface of the same tile

  7. Determination of radon exhalation rates from tiles using active and passive techniques

    Energy Technology Data Exchange (ETDEWEB)

    Al-Jarallah, M.I. E-mail: mibrahim@kfupm.edu.sa; Abu-Jarad, F.; Fazal-ur-Rehman

    2001-06-01

    Measurements of radon exhalation rates for selected samples of tiles used in Saudi Arabia were carried out using active and passive measuring techniques. These samples were granite, marble and ceramic. In the active method, a PC-based radon gas analyzer with emanation container was used, while, in the passive method, PM-355 nuclear track detectors with the 'can technique' were applied for 180 days. A comparison of the exhalation rates measured by the two techniques showed a good linear correlation coefficient of 0.7. The granite samples showed an average radon exhalation rate of 0.7 Bq m{sup -2} h{sup -1}, which was higher than that of marble and ceramic by more than twofold. The radon exhalation rates measured by the 'can technique' showed a non-uniform exhalation from the surface of the same tile.

  8. Comparison of classical and molecular techniques for the determination of microbial biodiversity in Mediterranean crop soils

    Energy Technology Data Exchange (ETDEWEB)

    Munoz, A.; Lopez-Pineiro, A.; Ramirez, M.

    2009-07-01

    Soil microbe ecology has lately become increasingly important in the study of soil microbe populations. direct extraction of soil bacteria DNA allows PCR and DGGE analyses for the microorganism identification of these complex samples, avoiding the need for time-consuming culture-dependent techniques. The aim of the present study was to compare the two techniques (culture-dependent and molecular culture-independent) in four different plots of maize (Zea mays L.) crop under irrigation in south-western Spain. (Author)

  9. Density determination of langmuir-blodgett monolayer films using x-ray reflectivity technique

    International Nuclear Information System (INIS)

    Damar Yoga Kusuma

    2015-01-01

    Monolayer deposition by Langmuir-Blodgett technique produces monolayer films that are uniform with controllable thickness down to nanometer scale. To evaluate the quality of the monolayer deposition, X-ray reflectivity technique are employed to monitor the monolayers density. Langmuir-Blodgett monolayer with good coverage and uniformity results in film density close to its macroscopic film counterpart whereas films with presence of air gaps shows lower density compared to its macroscopic film counterpart. (author)

  10. Review of procedures involving separation and preconcentration for the determination of cadmium using spectrometric techniques

    International Nuclear Information System (INIS)

    Ferreira, Sergio L.C.; Andrade, Jailson B. de; Korn, Maria das Gracas A.; Pereira, Madson de G.; Lemos, Valfredo A.; Santos, Walter N.L. dos; Rodrigues, Frederico de Medeiros; Souza, Anderson S.; Ferreira, Hadla S.; Silva, Erik G.P. da

    2007-01-01

    Spectrometric techniques for the analysis of trace cadmium have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, such as electrochemical deposition, precipitation, coprecipitation, solid phase extraction, liquid-liquid extraction (LLE) and cloud point extraction (CPE), and consider the features of the their application with several spectrometric techniques

  11. Determination of boron in aqueous solutions by solid state nuclear track detectors technique, using a filtered neutron beam

    International Nuclear Information System (INIS)

    Moraes, M.A.P.V. de; Pugliesi, R.; Khouri, M.T.F.C.

    1985-11-01

    The solid state nuclear track detectors technique has been used for determination of boron in aqueous solutions, using a filtered neutron beam. The particles tracks from the 10 B(n,α)Li 7 reaction were registered in the CR-39 film, chemically etched in a (30%) KOH solution 70 0 C during 90 minutes. The obtained results showed the usefulness of this technique for boron determination in the ppm range. The inferior detectable limit was 9 ppm. The combined track registration efficiency factor K has been evaluated in the solutions, for the CR-39 detector and its values is K= (4,60 - + 0,06). 10 -4 cm. (Author) [pt

  12. Determination of nuclear fuel burn-up using mass spectrometric techniques

    International Nuclear Information System (INIS)

    Saha, B.; Bagyalakshmi, R.; Periaswami, G.; Kavimandan, V.D.; Chitambar, S.A.; Jain, H.C.; Mathews, C.K.

    1977-01-01

    Determination of burn-up using a stable fission product monitor such as 148 Nd and heavy elements, determined by isotope dilution mass spectrometry gives the most accurate data. This report describes the work carried out to standardise the conditions for burn-up determination. Some typical results are given. (author)

  13. Comparison of 4 analytical techniques based on atomic spectrometry for the determination of total tin in canned foodstuffs

    OpenAIRE

    2011-01-01

    Abstract Different techniques for the determination of total tin in beverage and canned food by atomic spectrometry were compared. The performance characteristics of Inductively Coupled Plasma Mass Spectrometry (ICP-MS), Hydride Generation Inductively Coupled Plasma Atomic Emission Spectrometry (HG-ICP-AES), Electrothermal Atomization Atomic Absorption Spectrometry (ETA-AAS) and Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) were determined in term of linearity, ...

  14. Reliability of Electrochemical Techniques for Determining Corrosion Rates on Carbon Steel in Sulfide Media

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Hemmingsen, T.; Nielsen, Lars Vendelbo

    2007-01-01

    if the biofilm in combination with ferrous sulfide corrosion products cover the steel surface. Corrosion rates can be overestimated by a factor of 10 to 100 with electrochemical techniques - both by linear polarization resistance (LPR) and electrochemicel impedance spectroscopy (EIS). Oxygen entering the system......Effects of film formation on carbon steel in hydrogen sulfide (H2S) media may corrupt corrosion rate monitoring by electrochemical techniques. Electrochemical data from H2S solutions, biological sulfide media, and natural sulfide containing geothermal water have been collected, and the process...... of film formation in sulfide solutins was followed by video. It can be shown that capacitative and diffusional effects due to porous reactive deposits tend to dominate the data, resulting in unreliable corrosion rates measured using electrochemical techniques. The effect is strongly increased...

  15. Z-scan: A simple technique for determination of third-order optical nonlinearity

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Vijender, E-mail: chahal-gju@rediffmail.com [Department of Applied Science, N.C. College of Engineering, Israna, Panipat-132107, Haryana (India); Aghamkar, Praveen, E-mail: p-aghamkar@yahoo.co.in [Department of Physics, Chaudhary Devi Lal University, Sirsa-125055, Haryana (India)

    2015-08-28

    Z-scan is a simple experimental technique to measure intensity dependent nonlinear susceptibilities of third-order nonlinear optical materials. This technique is used to measure the sign and magnitude of both real and imaginary part of the third order nonlinear susceptibility (χ{sup (3)}) of nonlinear optical materials. In this paper, we investigate third-order nonlinear optical properties of Ag-polymer composite film by using single beam z-scan technique with Q-switched, frequency doubled Nd: YAG laser (λ=532 nm) at 5 ns pulse. The values of nonlinear absorption coefficient (β), nonlinear refractive index (n{sub 2}) and third-order nonlinear optical susceptibility (χ{sup (3)}) of permethylazine were found to be 9.64 × 10{sup −7} cm/W, 8.55 × 10{sup −12} cm{sup 2}/W and 5.48 × 10{sup −10} esu, respectively.

  16. [Determination of acetanilide herbicide residues in tea by gas chromatography-mass spectrometry with two different ionization techniques].

    Science.gov (United States)

    Shen, Weijian; Xu, Jinzhong; Yang, Wenquan; Shen, Chongyu; Zhao, Zengyun; Ding, Tao; Wu, Bin

    2007-09-01

    An analytical method of solid phase extraction-gas chromatography-mass spectrometry with two different ionization techniques was established for simultaneous determination of 12 acetanilide herbicide residues in tea-leaves. Herbicides were extracted from tea-leaf samples with ethyl acetate. The extract was cleaned-up on an active carbon SPE column connected to a Florisil SPE column. Analytical screening was determined by the technique of gas chromatography (GC)-mass spectrometry (MS) in the selected ion monitoring (SIM) mode with either electron impact ionization (EI) or negative chemical ionization (NCI). It is reliable and stable that the recoveries of all herbicides were in the range from 50% to 110% at three spiked levels, 10 microg/kg, 20 microg/kg and 40 microg/kg, and the relative standard deviations (RSDs) were no more than 10.9%. The two different ionization techniques are complementary as more ion fragmentation information can be obtained from the EI mode while more molecular ion information from the NCI mode. By comparison of the two techniques, the selectivity of NCI-SIM was much better than that of EI-SIM method. The sensitivities of the both techniques were high, the limit of quantitative (LOQ) for each herbicide was no more than 2.0 microg/kg, and the limit of detection (LOD) with NCI-SIM technique was much lower than that of EI-SIM when analyzing herbicides with several halogen atoms in the molecule.

  17. Improvements in technique for determining the surfactant penetration in hair fibres using scanning ion beam analyses

    International Nuclear Information System (INIS)

    Hollands, R.; Clough, A.S.; Meredith, P.

    1999-01-01

    The penetration abilities of surfactants need to be known by companies manufacturing hair-care products. In this work three complementary techniques were used simultaneously - PIXE, NRA and RBS - to measure the penetration of a surfactant, which had been deuterated, into permed hair fibres. Using a scanning micro-beam of 2 MeV 3 He ions 2-dimensional concentration maps were obtained which showed whether the surfactant penetrated the fibre or just stayed on the surface. This is the first report of the use of three simultaneous scattering techniques with a scanning micro-beam. (author)

  18. A pilot study to determine the effect of radiographer training on radiostereometric analysis imaging technique

    DEFF Research Database (Denmark)

    Muharemovic, O; Troelsen, A; Thomsen, M G

    2018-01-01

    INTRODUCTION: Producing x-ray images for radiostereometric analysis (RSA) is a demanding technique. Suboptimal examinations result in a high percentage of exposure repetition. The aim of this pilot study was to use an experiential training approach to sharpen the skills of radiographers in acquir......INTRODUCTION: Producing x-ray images for radiostereometric analysis (RSA) is a demanding technique. Suboptimal examinations result in a high percentage of exposure repetition. The aim of this pilot study was to use an experiential training approach to sharpen the skills of radiographers...

  19. Investigation of Load Prediction on the Mexico Rotor Using the Technique of Determination of the Angle of Attack

    DEFF Research Database (Denmark)

    Yang, Hua; Shen, Wen Zhong; Sørensen, Jens Nørkær

    2012-01-01

    Blade element moment (BEM) is a widely used technique for prediction of wind turbine aerodynamics performance, the reliability of airfoil data is an important factor to improve the prediction accuracy of aerodynamic loads and power using a BEM code. The method of determination of angle of attack ...

  20. Film techniques in radiotherapy for treatment verification, determination of patient exit dose, and detection of localization error

    International Nuclear Information System (INIS)

    Haus, A.G.; Marks, J.E.

    1974-01-01

    In patient radiation therapy, it is important to know that the diseased area is included in the treatment field and that normal anatomy is properly shielded or excluded. Since 1969, a film technique developed for imaging of the complete patient radiation exposure has been applied for treatment verification and for the detection and evaluation of localization errors that may occur during treatment. The technique basically consists of placing a film under the patient during the entire radiation exposure. This film should have proper sensitivity and contrast in the exit dose exposure range encountered in radiotherapy. In this communication, we describe how various exit doses fit the characteristic curve of the film; examples of films exposed to various exit doses; the technique for using the film to determine the spatial distribution of the absorbed exit dose; and types of errors commonly detected. Results are presented illustrating that, as the frequency of use of this film technique is increased, localization error is reduced significantly

  1. A modification of the Daisy II - 220 technique for the determination of ...

    African Journals Online (AJOL)

    Unknown

    digestibility using rumen fluid/cellulase have been used extensively in laboratories worldwide. These techniques use individual digestion containers shaken twice daily and a two-stage 48 h digestion. Due to the individual sample handling, filtration and washing steps performed, the introduction of human error and amount ...

  2. An in vitro study to determine fracture resistance of tooth roots after different instrumentation techniques

    Directory of Open Access Journals (Sweden)

    Marri Shilpa Reddy

    2016-01-01

    Conclusion: Preparation of canals with a conventional hand instrumentation technique using 0.02 taper K-files showed highest fracture resistance with least amount of dentin removed at all levels followed by Endowave, ProTaper Hand, and Rotary files.

  3. A review of analytical techniques to determine long-lived radiobiologically significant nuclides in encapsulated waste

    International Nuclear Information System (INIS)

    Amey, M.H.D.; Kenward, D.; Symons, W.J.

    1985-05-01

    Methods have been identified, or are proposed for, most of the radionuclides considered important for long term storage. From the information obtained the development of liquid chromatography together with an in-line radiochemical detector is proposed as a powerful technique for sequential separation and analysis of multi-component systems. (UK)

  4. Application of modelling techniques in the food industry: determination of shelf-life for chilled foods

    NARCIS (Netherlands)

    Membré, J.M.; Johnston, M.D.; Bassett, J.; Naaktgeboren, G.; Blackburn, W.; Gorris, L.G.M.

    2005-01-01

    Microbiological modelling techniques (predictive microbiology, the Bayesian Markov Chain Monte Carlo method and a probability risk assessment approach) were combined to assess the shelf-life of an in-pack heat-treated, low-acid sauce intended to be marketed under chilled conditions. From a safety

  5. Determination of the diffusion coefficient of oxygen in sodium chloride solutions with a transient pulse technique

    NARCIS (Netherlands)

    van Stroe, A.J.; Janssen, L.J.J.

    1993-01-01

    An accurate and rapid method for detg. the diffusion coeffs. of electrochem. active gases in electrolytes is described. The technique is based on chronoamperometry where transient currents are measured and interpreted with a Cottrell-related equation. The diffusion coeffs. of oxygen were detd. for

  6. Proposed satellite position determination systems and techniques for Geostationary Synthetic Aperture Radar

    OpenAIRE

    Martin Fuster, Roger; Fernández Usón, Marc; Casado Blanco, David; Broquetas Ibars, Antoni

    2016-01-01

    This paper proposes two different calibration techniques for Geostationary Synthetic Aperture Radar (GEOSAR) missions requiring a high precision positioning, based on Active Radar Calibrators and Ground Based Interferometry. The research is enclosed in the preparation studies of a future GEOSAR mission providing continuous monitoring at continental scale. Peer Reviewed

  7. Simulation of limiting dilution technique in determination of immunocompetent cells frequency in irradiated cell cultures

    International Nuclear Information System (INIS)

    Martini Filho, R.J.; Barlette, V.E.; Goes, E.G.; Covas, D.T.; Orellana, M.

    2001-01-01

    Limiting dilution techniques (LDA) dose-response data have been used to detect immunocompetent T-Cells in microcultures. In this work, LDA frequencies estimates was obtained using χ2 minimization for irradiated cells in a range of 500 to 1,500 cGy. (author)

  8. Review and Ranking of NDA Techniques to Determine Plutonium Content in Spent Fuel

    International Nuclear Information System (INIS)

    Cheatham, Jesse R.; Wagner, John C.

    2010-01-01

    A number of efforts are under way to improve nondestructive assay (NDA) techniques for spent nuclear fuel (SNF) safeguard applications. These efforts have largely focused on advancing individual NDA approaches to assay plutonium content. Although significant improvements have been made in NDA techniques, relatively little work has been done to thoroughly and systematically compare the methods. A comparative review of the relative strengths and weaknesses of current NDA techniques brings a new perspective to guide future research. To gauge the practicality and effectiveness of the various relevant NDA approaches, criteria have been developed from two broad categories: functionality and operability. The functionality category includes accuracy estimates, measurement time, plutonium verification capabilities, and assembly or fuel rod assay. Since SNF composition changes with operational history and cooling times, the viability of certain NDA approaches will also change over time. While active interrogation approaches will benefit from reduced background radiation, passive assays will lose the information contained in short-lived isotopes. Therefore, the expected assay accuracy as a function of time is considered. The operability category attempts to gauge the challenges associated with the application of different NDA techniques. This category examines the NDA deploy-ability, measurement capabilities and constraints in spent fuel pools, required on-site facilities, NDA technique synergies, and the extent to which the measurements are obtrusive to the facility. Each topic listed in the categories will be given a numerical score used to rank the different NDA approaches. While the combined numerical score of each technique is informative, the individual-topic scoring will allow for a more-tailored ranking approach. Since the needs and tools of the International Atomic Energy Agency differ from those of a recycling facility, the best assay technique may change with users

  9. Standard Test Method for Determining Thermal Neutron Reaction Rates and Thermal Neutron Fluence Rates by Radioactivation Techniques

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 The purpose of this test method is to define a general procedure for determining an unknown thermal-neutron fluence rate by neutron activation techniques. It is not practicable to describe completely a technique applicable to the large number of experimental situations that require the measurement of a thermal-neutron fluence rate. Therefore, this method is presented so that the user may adapt to his particular situation the fundamental procedures of the following techniques. 1.1.1 Radiometric counting technique using pure cobalt, pure gold, pure indium, cobalt-aluminum, alloy, gold-aluminum alloy, or indium-aluminum alloy. 1.1.2 Standard comparison technique using pure gold, or gold-aluminum alloy, and 1.1.3 Secondary standard comparison techniques using pure indium, indium-aluminum alloy, pure dysprosium, or dysprosium-aluminum alloy. 1.2 The techniques presented are limited to measurements at room temperatures. However, special problems when making thermal-neutron fluence rate measurements in high-...

  10. Determine Conjugate Points of an Aerial Photograph Stereopairs using Seperate Channel Mean Value Technique

    Directory of Open Access Journals (Sweden)

    Andri Hernandi

    2009-11-01

    Full Text Available In the development of digital photogrammetric system, automatic image matching process play an important role. The automatic image matching is used in finding the conjugate points of an aerial photograph stereopair automatically. This matching technique gives quite significant contribution especially in the development of 3D photogrammetry in an attempt to get the exact and precise topographic information during the stereo restitution. There are two image matching methods that have been so far developed, i.e. the area based system for gray level environment and the feature based system for natural feature environment. This re¬search is trying to implement the area based matching with normalized cross correlation technique to get the correlation coefficient between the spectral value of the left image and its pair on the right. Based on the previous researches, the use of color image could increase the quality of match-ing. One of the color image matching technique is known as Separate Channel Mean Value. In order to be able to see the performance of the technique, a number of sampling areas with various different characteristics have been chosen, i.e. the heterogeneous, homogeneous, texture, shadow, and contrast. The result shows the highest similarity measure is obtained on heterogeneous sample area at size of all reference and search image, i.e. (11 pixels x 11 pixels and (23 pixels x 23 pixels. In these area the correlation coefficient reached more than 0.7 and the highest percentage of similarity measure is obtained. The average of total similarity measure of conjugate images in the sampling image area only reach about 41.43 % of success. Therefore, this technique has a weakness and some treatment to overcome the problems is still needed.

  11. Determination of Seric E immuno-globulins. Comparison of two techniques, radioimmunological and immuno enzymatic. Clinical correlations

    International Nuclear Information System (INIS)

    Lafosse-Marin, Sylvie.

    1977-09-01

    Because of the very low seric IgE concentrations their research and analysis are difficult and many techniques of a more or less sophisticated kind have been proposed for this reason. Our aim was to compare two total seric IgE determination methods: one recent, the enzymmuno-Plaque-Pasteur (EPP); the other, most commonly used at present, the Radio-Immuno-Sorbent-Test (RIST). For this we measured total seric IgE in a hundred and one children by the EPP technique and compared our results with those supplied from the same samples by a laboratory using the RIST technique; the results were then correlated with clinical evidence. The technique proposed by the Pasteur Institute to determine total seric IgE is based on radial immunodiffusion sensitized by the use of antibodies labelled with glucose oxydase. This simple technique, easy to use, requires no expensive materials but has two disadvantages: it takes rather a long time and can only measure IgE concentrations of 50 UI/ml or more. The RIST technique is based on competitive fixation, onto anti-IgE-coated Sephadex particles of the IgE under analysis and of a fixed dose of radio-labelled IgE. This second technique, though faster, has the major disadvantage of being practicable in few laboratories because of the heavy equipment needed and the radioactivity used. This study has shown on the whole an equivalence (correlation coefficient 0.95) between the results given by the two techniques: EPP and RIST (the comparison was made between the IgE contents and not their logarithm) [fr

  12. Experimental-calculation technique for Ksub(IC) determination using the samples of decreased dimensions

    International Nuclear Information System (INIS)

    Vinokurov, V.A.; Dymshits, A.V.; Pirusskij, M.V.; Ovsyannikov, B.M.; Kononov, V.V.

    1981-01-01

    A possibility to decrease the size of samples, which is necessary for the reliable determination of fractUre toughness Ksub(1c), is established. The dependences of crack-resistance caracteristics on the sample dimensions are determined experimentally. The static bending tests are made using the 1251 model of ''Instron'' installation with a specially designed device. The samples of the 20KhNMF steel have been tested. It is shown that the Ksub(1c) value, determined for the samples with the largest netto cross section (50x100 rm), is considerably lower than Ksub(1c) values, determined for the samples with the decreased sizes. it is shown that the developed experimental-calculated method of Ksub(1c) determination can be practically used for the samples of the decreased sizes with the introduction of the corresponding amendment coefficient [ru

  13. Non-conventional measurement techniques for the determination of some long-lived radionuclides produced in nuclear fuel

    International Nuclear Information System (INIS)

    Rosenberg, R.J.

    1992-04-01

    The results of a literature survey on non-radiometric analytical techniques for the determination of long-lived radionuclides are described. The methods which have been considered are accelerator mass spectrometry, inductively coupled plasma mass spectrometry, thermal ionization mass spectrometry, resonance ionization spectrometry, resonance ionization mass spectrometry and neutron activation analysis. Neutron activation analysis has been commonly used for the determination of 129 I and 237 Np in environmental samples. Inductively coupled mass spectrometry seems likely to become the method of choice for the determination of 99 Tc, 237 Np and Pu-isotopes. The methods are discussed and the chemical separation methods described. (orig.)

  14. Assessment of Equipment for the Determination of Nutrients in Marine Waters: A Case Study of the Microplate Technique

    Science.gov (United States)

    Aminot, A.

    1996-09-01

    An essential prerequisite for quality assurance of the colorimetric determination of nutrients in seawater is the use of suitable photometric equipment. Based on a knowledge of the optical characteristics of a particular system and the absorption coefficient of the analyte, a statistical approach can be used to predict the limit of detection and the limit of quantitation for a given determinand. The microplate technique, widely used for bioassays, is applicable to colorimetric analysis in general, and its use for the determination of nutrients in seawater has been suggested. This paper reports a theoretical assessment of its capabilities in this context and a practical check on its performance, taking the determination of nitrite in seawater as typical. The conclusion is that short optical path length and insufficient repeatability of the absorbance measurement render it unsuitable for the determination of the low concentrations generally encountered in marine work, with the possible exception of nitrate. The perceived advantage of high-speed analysis is a secondary consideration in the overall process of determining nutrients, and the microplate technique's small scale of operation is a definite disadvantage as this increases the risk of exposure to contamination problems, in comparison with conventional techniques.

  15. Determination of moisture content gradient in wood by gamma-ray attenuation technique

    International Nuclear Information System (INIS)

    Aguiar, O.; Barros Ferraz, E.S. de

    1981-01-01

    A new methodology for determining water content gradients in wood was developed. It was based on the low energy gamma ray attenuation. Two equations were proposed for determining wood water content, below and above the fiber saturation point. A series of measurents of moisture content gradients in wood samples of Pinus oocarpa was made, during drying in an environment with controlled relative humidity and temperature. The water cntent gradients determination was quick, non-destructive and presented sensitivity and accuracy in moisture content range from 9% to 150%. Aspects of the application of this methodology in water diffusion and flow studies in wood are discussed. (Author) [pt

  16. Development of basic theories and techniques for determining stresses in rotating turbine or compressor blades

    Science.gov (United States)

    Chien, C. H.; Swinson, W. F.; Turner, J. L.; Moslehy, F. A.; Ranson, W. F.

    1980-01-01

    A method for measuring in-plane displacement of a rotating structure by using two laser speckle photographs is described. From the displacement measurements one can calculate strains and stresses due to a centrifugal load. This technique involves making separate speckle photographs of a test model. One photograph is made with the model loaded (model is rotating); the second photograph is made with no load on the model (model is stationary). A sandwich is constructed from the two speckle photographs and data are recovered in a manner similar to that used with conventional speckle photography. The basic theory, experimental procedures of this method, and data analysis of a simple rotating specimen are described. In addition the measurement of in-plane surface displacement components of a deformed solid, and the application of the coupled laser speckle interferometry and boundary-integral solution technique to two dimensional elasticity problems are addressed.

  17. Determination of total uranium by mass spectrometry utilizing the isotopic dilution technique

    International Nuclear Information System (INIS)

    Cretella, R.F.; Noutary, C.J.; Servant, R.E.

    1981-01-01

    The isotopic dilution associated to mass spectrometry is a high-sensitivity technique that allows to work with microquantities of the sample, making it possible to analize the content in highly radioactive solutions with excellent accuracy and minimum risk. The proposed technique is described and its results are discussed through the analysis of: 1) A synthetic sample that simulates dissolved spent fuel elements; 2) Uranium dioxide of nuclear purity and 3) Uranium concentrate. 233 U(ORNL) was employed as a tracer and a Nuclide 12-90-SU mass spectrometer of simple magnetic focus as measurement instrument. The accuracy reached in the analyses is better than 0.5% with a reliability of 95%. The analysis of the errors shows that their main contributing source are the errors in the measurement of the isotopic ratios. (M.E.L.) [es

  18. Bioavailability of iron to rats from processed soybean fractions determined by intrinsic and extrinsic labeling techniques

    International Nuclear Information System (INIS)

    Weaver, C.M.; Nelson, N.; Elliott, J.G.

    1984-01-01

    Intrinsic and extrinsic labeling techniques were used to measure iron bioavailability from soybean fractions (isolated soy protein, defatted flour, soy hulls, insoluble material and whey) by iron-depleted and non-iron-depleted rats. As expected, absorption of iron was higher in the iron-depleted than in the non-iron-depleted rats. In the iron-depleted group, significantly more iron was absorbed from soy whey than from other fractions. No other significant difference in iron absorption associated with iron source was observed. The higher absorption rate of iron from whey by the iron-depleted rats probably was related to a lower quantity of food consumed during the test meal by this group. Intrinsic and extrinsic labeling techniques produced similar assessments of bioavailability of iron

  19. Review of some recent techniques of age determination of blow flies having forensic implications

    Directory of Open Access Journals (Sweden)

    Madhu Bala

    2016-09-01

    Full Text Available Forensic entomology can aid death investigation by using predictable developmental changes to estimate the age of flies associated with a body. Forensic entomologists use size and developmental stages to estimate blowfly age, and from those, a Postmortem Interval. Calliphorids are very interesting in forensic sciences from an applied point of view, because they provide relevant evidence for estimating the Postmortem Interval. Since such estimates are generally accurate but often lack precision, particularly in the older developmental stages, so there is a need of some alternative aging methods. The range of techniques available for age grading of adult insects is reviewed, with particular emphasis on species of medical importance. The techniques described include pteridine fluorescence analysis, internal morphological analysis, cuticular hydrocarbon analysis, gene expression analysis, cuticular banding pattern analysis, volatile organic compounds analysis released by larvae and pupae.

  20. Optimal parameters determination of the orbital weld technique using microstructural and chemical properties of welded joint

    International Nuclear Information System (INIS)

    Miranda, A.; Echevarria, J.F.; Rondon, S.; Leiva, P.; Sendoya, F.A.; Amalfi, J.; Lopez, M.; Dominguez, H.

    1999-01-01

    The paper deals with the study of the main parameters of thermal cycle in Orbital Automatic Weld, as a particular process of the GTAW Weld technique. Also is concerned with the investigation of microstructural and mechanical properties of welded joints made with Orbital Technique in SA 210 Steel, a particular alloy widely use during the construction of Economizers of Power Plants. A number of PC software were used in this sense in order to anticipate the main mechanical and structural characteristics of Weld metal and the Heat Affected Zone (HAZ). The papers also might be of great value during selection of optimal Weld parameters to produce sound and high quality Welds during the construction / assembling of structural components in high requirements industrial sectors and also to make a reliable prediction of weld properties

  1. Determination of cesium and selenium in cultivated mushrooms using radionuclide X-ray fluorescence technique

    International Nuclear Information System (INIS)

    Racz, L.; Bumbalova, A.; Harangozo, M.; Toelgyessy, J.; Tomecek, O.

    2000-01-01

    Cesium and selenium intake of cultivated mushrooms (Agaricus bisporus), with these elements previously added to culture medium, has been examined from the viewpoint of health- and environmental protection. The process of measuring has been carried out by the radionuclide X-ray fluorescence technique. Treatments of the elementary substance with Se salt appears to influence the Se content of the mushrooms to a significant extent. Cs intake is of considerable importance, as this element is accumulated by mushrooms. (author)

  2. Electroacoustic isoelectric point determinations of bauxite refinery residues: different neutralization techniques and minor mineral effects.

    Science.gov (United States)

    Freire, Tiago S S; Clark, Malcolm W; Comarmond, M Josick; Payne, Timothy E; Reichelt-Brushett, Amanda J; Thorogood, Gordon J

    2012-08-14

    Bauxite refinery residue (BRR) is a highly caustic, iron hydroxide-rich byproduct from alumina production. Some chemical treatments of BRR reduce soluble alkalinity and lower residue pH (to values work shows that minor mineral components in complex mineral systems may have a disproportionate effect on the observable bulk IEP. Furthermore, this work shows the appropriateness of electroacoustic techniques in investigating samples with significant soluble mineral components (e.g., ANC).

  3. Nuclear method for determination of nitrogen depth distributions in single seeds. [/sup 14/N tracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Sundqvist, B; Gonczi, L; Koersner, I; Bergman, R; Lindh, U

    1974-01-01

    (d,p) reactions in /sup 14/N were used for probing single kernels of seed for nitrogen content and nitrogen depth distributions. Comparison with the Kjeldahl method was made on individual peas and beans. The results were found to be strongly correlated. The technique to obtain depth distributions of nitrogen was also used on high- and low-lysine varieties of barley for which large differences in nitrogen distributions were found.

  4. Determination of solid flow for bottom sediment drag of Parana river using tracer techniques

    International Nuclear Information System (INIS)

    Aoki, Pedro E.; Enokihara, Cyro T.; Rocca, Hector C.C.; Bittencourt, Andre V.L.

    1997-01-01

    Radioactive tracing technique with labeled sand was employed to evaluate the bottom sediment drag of Parana River, near Guaira City, State of Parana. 198 Au radioisotope was used and measurements have been performed for a period of fifteen days. A bed load rate of 914,8 t/day was obtained for a laminar layer of 0,33 mean thickness and 1,65 m/day mean velocity. (author). 5 refs., 7 figs., 3 tabs

  5. Analytical and laser scanning techniques to determine shape properties of aggregates used in pavements

    CSIR Research Space (South Africa)

    Komba, Julius J

    2013-06-01

    Full Text Available and volume of an aggregate particle, the sphericity computed by using orthogonal dimensions of an aggregate particle, and the flat and elongated ratio computed by using longest and smallest dimensions of an aggregate particle. The second approach employed.... Further validation of the laser-based technique was achieved by correlating the laser-based aggregate form indices with the results from two current standard tests; the flakiness index and the flat and elongated particles ratio tests. The laser...

  6. Determination of sulfate in thorium salts using gravimetric technique with previous thorium separation

    International Nuclear Information System (INIS)

    Silva, C.M. da; Pires, M.A.F.

    1994-01-01

    Available as short communication only. A simple analytical method to analyze sulfates in thorium salt, is presented. The method is based on the thorium separation as hydroxide. The gravimetric technique is used to analyze the sulfate in the filtered as barium sulfate. Using this method, the sulfate separation from thorium has been reach 99,9% yield, and 0,1% precision. This method is applied to thorium salts specifically thorium sulfate, carbonate and nitrate. (author). 5 refs, 2 tabs

  7. Wet effluent diffusion denuder technique and the determination of volatile organic compounds in air. II. Monoterpenes

    Czech Academy of Sciences Publication Activity Database

    Sklenská, Jana; Broškovičová, Anna; Večeřa, Zbyněk

    2002-01-01

    Roč. 973, 1-2 (2002), s. 211-216 ISSN 0021-9673 R&D Projects: GA ČR GA203/98/0943 Grant - others:SPSDII(XE) EV/02/11 Institutional research plan: CEZ:AV0Z4031919 Keywords : wet effluent denuder technique * volatile organic compounds * monoterpenes Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.098, year: 2002

  8. Quantitative determination of the intensities of known components in spectra obtained from surface analytical techniques

    International Nuclear Information System (INIS)

    Nelson, G.C.

    1984-01-01

    Linear least-squares methods have been used to quantitatively decompose experimental data obtained from surface analytical techniques into its separate components. The mathematical procedure for accomplishing this is described and examples are given of the use of this method with data obtained from Auger electron spectroscopy [both N(E) and derivative], x-ray photoelectron spectroscopy, and low energy ion scattering spectroscopy. The requirements on the quality of the data are discussed

  9. Determination of nitrous acid in air using wet effluent diffusion denuder–FIA technique

    Czech Academy of Sciences Publication Activity Database

    Mikuška, Pavel; Motyka, Kamil; Večeřa, Zbyněk

    2008-01-01

    Roč. 77, č. 2 (2008), s. 635-641 ISSN 0039-9140. [International Conference on Flow Injection Analysis and Related Techniques. Berlin, 02.09.2007-07.09.2007] R&D Projects: GA MŽP SP/1B7/189/07 Institutional research plan: CEZ:AV0Z40310501 Keywords : nitrous acid * wet effluent diffusion denuder * FIA Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.206, year: 2008

  10. Determination of toxic elements in beauty creams by X-ray spectrometric techniques (2001-2002)

    International Nuclear Information System (INIS)

    War-War-Myo-Aung

    2002-01-01

    This paper is carried out to examine the contents of toxic heavy metals in various kinds of beauty creams by using Energy Dispersive X-ray Fluorescence Technique (EDXRF). By applying EDXRF system, it si found that most of the beauty creams contained titanium and zinc, and some of the beauty creams contained lead, bismuth, iron and mercury. Among the heavy toxic metals, mercury is the most harmful to human's health. (author)

  11. Modified emission-transmission method for determining trace elements in solid samples using the XRF techniques

    International Nuclear Information System (INIS)

    Poblete, V.; Alvarez, M.; Hermosilla, M.

    2000-01-01

    This is a study of an analysis of trace elements in medium thick solid samples, by the modified transmission emission method, using the energy dispersion X-ray fluorescence technique (EDXRF). The effects of absorption and reinforcement are the main disadvantages of the EDXRF technique for the quantitative analysis of bigger elements and trace elements in solid samples. The implementation of this method and its application to a variety of samples was carried out using an infinitely thick multi-element white sample that calculates the correction factors by absorbing all the analytes in the sample. The discontinuities in the masic absorption coefficients versus energies association for each element, with medium thick and homogenous samples, are analyzed and corrected. A thorough analysis of the different theoretical and test variables are proven by using real samples, including certified material with known concentration. The simplicity of the calculation method and the results obtained show the method's major precision, with possibilities for the non-destructive routine analysis of different solid samples, using the EDXRF technique (author)

  12. Analytical and laser scanning techniques to determine shape properties of mineral aggregates

    CSIR Research Space (South Africa)

    Komba, Julius J

    2013-01-01

    Full Text Available processed to reconstruct 3-D models of the aggregate particles. The models were further analyzed to determine the form properties. In this paper, two analysis approaches, based on aggregate physical properties and spherical harmonic analysis, were employed...

  13. Uranyl determination using pyridylazoresorcinol as complexing active by adsorb voltametry technique with cathodic redissolution

    International Nuclear Information System (INIS)

    Ohara, A.K.; Farias, P.A.M.

    1990-01-01

    The development method for uranyl ion determination by the optimization of chemical reaction and instrumental parameters is shown. This method is based on preconcentration stage, where in adsorptive accumulation of metallic complex in a static electrode is presented. (author)

  14. Specific features of the determination of residual stresses in materials by diffraction techniques

    Science.gov (United States)

    Gorkunov, E. S.; Zadvorkin, S. M.; Goruleva, L. S.

    2017-12-01

    Residual stresses arising in separate machine parts and structural components during production and use to a large extent govern their lifetime. In this connection, the development and improvement of nondestructive methods for the determination of residual stresses is an important task for nondestructive testing. Standards regulate only the determination of macroscopic stresses, and in practice these stresses are most often determined with the application of the sin2ψ method. This paper, using quenched structural steels as an example, compares the results of residual stress determination by the sin2ψ method with those obtained by the method based on the analysis of the diffraction line profile as dependent on the value of the irradiated volume. It is demonstrated that, as the irradiated volume decreases, the value of residual stresses determined by the sin2ψ method may vary considerably, up to the change of the sign. For a more complete characteristic of residual stresses it is proposed to use, besides the determination of macrostresses by the shift of the diffraction lines, the value of microscopic stresses calculated from the line profile analysis.

  15. Comparative studies of method for determining total mercury in fish. Dithizone and flameless atomic absorption spectrophotometry techniques

    International Nuclear Information System (INIS)

    Protasowicki, M.; Ociepa, A.; Chodyniecki, A.

    1977-01-01

    Two methods for determining total mercury in fish were compared: the dithizone and flameless atomic absorption spectrophotometry techniques. The studies involved determination of recovery when 1μg of mercury as solutions of HgCl 2 or CH 3 HgC were added to each sample of herring flesh. Mean recoveries in the dithizone method were found to be 91.4+-7.47% and 90.25+-4.73% for the two solutions respectively, while the recoveries obtained with the flameless atomic absorption spectrophotometry were 95.00+-9.13% and 98.70+-7.14%, respectively. Both techniques were used to determine the mercury content in the same herring flesh sample. The first technique showed the content of 0.050+-0.018μg Hg g -1 while the result obtained with the other one was 0.062+-0.013μg Hg g -1 . The statistical treatment of the results obtained showed no difference between the two techniques, the significance level being α=0.05. Therefore, the results obtained with the dithizone method are comparable with those obtained with the flameless atomic absorption spectrophotometry for mercury contents of the magnitude order of 0.050 ug.g -1 . (author)

  16. Application of PIXE, NAA and other techniques for the determination of toxic elements in foodstuffs and drinking water in Bangladesh

    International Nuclear Information System (INIS)

    Tarafdar, S.A.; Khan, A.H.; Hadi, D.A.; Maroof, F.B.A.; Ali, M.

    1994-01-01

    An investigation was conducted on the status of trace and minor elements in some foodstuffs, meats and also drinking water in Bangladesh, using proton induced X-ray emission (PIXE), radioisotope-induced X-ray fluorescence (XRF), atomic absorption spectrophotometry (AAS) and also ion-selective electrode techniques. The elemental concentrations of K, Ca, Mn, Fe, Ni, Cu, Zn, As, Br, Rb and Sr, were determined in the samples by comparison with X-ray yield curves constructed from IAEA and NBS standard reference materials. Cadmium and zinc in the drinking water of Bangladesh was determined by AAS followed by solvent extraction technique. The total iodine content in different types of vegetables was determined by alkali ashing followed by the ion-selective electrode technique. The results indicate that none of the food regimes and also drinking water investigated here is burdened with heavy metals beyond permissible limits. The significance of the results is discussed in relation to human health an diseases. Three IAEA (2-1, and 2-2 and 2-3) secondary reference standard samples were also analyzed for intercomparison studied using PIXE and ASV techniques. (author). 4 refs, 7 tabs

  17. Determination of Cation Distributions in Mineral Structures by use of the Rietveld Full-Profile Refinement Technique

    International Nuclear Information System (INIS)

    Nord, A.G.

    1986-01-01

    Use of the Rietveld full-profile refinement technique with X-ray or neutron powder diffraction data for the determination of divalent-metal cation distributions in three mineral structure types (farringtonite, grafonite, sarcopside) is demonstrated. The accuracy of the conventional cation distribution coefficient Ksub(D) is about 5-10 percent with 24-46 parameters to be refined, and the averaged metal-oxygen distances are reliable and well correlated to the observed cation distribution pattern. In particular the usefulness of the Rietveld technique in combination with Moessbauer spectroscopy is stressed. Some concluding remarks are also given

  18. Determination of Cu, Cr, and As in preserved wood (Eucalyptus sp.) using x-ray fluorescent spectrometry techniques

    International Nuclear Information System (INIS)

    Sergio Matias Pereira Junior; Vera Akiko Maihara; Edson Goncalves Moreira; Vera Lucia Ribeiro Salvador; Ivone Mulako Sato

    2016-01-01

    Energy dispersive (EDXRF) and Portable (PXRF) X-ray fluorescence techniques are proposed for wood treatment control process and wood waste assortment. In this study, different retentions of chromated copper arsenate preservative were applied to Eucalyptus sp. sapwood samples. Cu, Cr and As were determined by XRF techniques in treated sapwood massive blocks and treated sapwood sawdust samples were analyzed by FAAS spectrometry (Flame Atomic Absorption) and INAA (Instrumental Neutron Activation Analysis). Cu, Cr and As mean values, obtained by FAASS and INAA, showed to be statically equal; however, XRF analysis showed considerable deviations, presenting the absorption and the enhancement effects in analytical lines. (author)

  19. Use of the azimuthal resistivity technique for determination of regional azimuth of transmissivity

    Science.gov (United States)

    Carlson, D.

    2010-01-01

    Many bedrock units contain joint sets that commonly act as preferred paths for the movement of water, electrical charge, and possible contaminants associated with production or transit of crude oil or refined products. To facilitate the development of remediation programs, a need exists to reliably determine regional-scale properties of these joint sets: azimuth of transmissivity ellipse, dominant set, and trend(s). The surface azimuthal electrical resistivity survey method used for local in situ studies can be a noninvasive, reliable, efficient, and relatively cost-effective method for regional studies. The azimuthal resistivity survey method combines the use of standard resistivity equipment with a Wenner array rotated about a fixed center point, at selected degree intervals, which yields an apparent resistivity ellipse from which joint-set orientation can be determined. Regional application of the azimuthal survey method was tested at 17 sites in an approximately 500 km2 (193 mi2) area around Milwaukee, Wisconsin, with less than 15m (50 ft) overburden above the dolomite. Results of 26 azimuthal surveys were compared and determined to be consistent with the results of two other methods: direct observation of joint-set orientation and transmissivity ellipses from multiple-well-aquifer tests. The average of joint-set trend determined by azimuthal surveys is within 2.5?? of the average of joint-set trend determined by direct observation of major joint sets at 24 sites. The average of maximum of transmissivity trend determined by azimuthal surveys is within 5.7?? of the average of maximum of transmissivity trend determined for 14 multiple-well-aquifer tests. Copyright ?? 2010 The American Association of Petroleum Geologists/Division of Environmental Geosciences. All rights reserved.

  20. Determination of trace elements in drinking tea by various analytical techniques

    International Nuclear Information System (INIS)

    Wang Chufang; Ke Chenghsiung; Yang Jenqyann

    1993-01-01

    Tea has been one of the most popular simulating beverages which is both heavily produced and consumed in Taiwan. The determination of minor or trace elements in drinking tea and tea leaves is therefore important for estimating the daily intake of Taiwanese considered as a safety indicator. In order to accurately and precisely determine the concentrations of trace elements in samples, several analytical methods such as AAS, NAA and ICP-AES are suggested. This paper attempts to utilize all three methods to determine the concentrations of minor or trace elements in different types of tea leaves and the extracts percolated from them. The influence of fermentation processes on the concentration levels of minor or trace elements in tea samples is investigated. Because only free metal ions are bioavailable for the human body, it is necessary to determine their concentrations in drinking tea. The dissolution of trace elements in drinking tea is therefore studied by simulating the common Chinese style of tea percolation. Concentrations of thirteen elements including Zn, Mn, Ca, Cu, Ni, Al, K, Mg, Cd, Pb, Na, Co and Sc are determined. (author) 14 refs.; 1 fig.; 6 tabs

  1. Improvements of neutron activation techniques for the determination of fissile material concentrations

    International Nuclear Information System (INIS)

    Papadopoulos, N.N.

    1987-01-01

    Certain experimental improvements, as variable sample size and irradiation position, automation and flexibility in radiation detection, broaden the measurable concentration range, increase the possible rate and accuracy of analysis and enlarge the application range of home-made nuclear analyzer for fissile material analysis by delayed fission neutron counting and for short-lived multielement analysis by neutron activation gamma-ray spectrometry. Intercomparisons of results by various methods and laboratories show the need for regular checks of techniques to ensure reliable measurements. (author)

  2. Determination of hyperacute kidney rejection in different xenogeneic system by 133xenon washout technique

    International Nuclear Information System (INIS)

    Welter, H.; Schmidt, K.R.; Pfeifer, K.J.; Hammer, C.; Chaussy, C.

    1980-01-01

    1. 133 Xenon washout technique is suitable for studying all stages of xenogeneic kidney rejection. 2. Follow-up studies allow differentiation between kidney rejection and kidneys in shock. 3. Changes of intrarenal blood flow distribution correlate with the histologic changes caused by rejection. 4. Total blood flow measurements employing 133 xenon washout yield 10-20% lower values compared with venous outflow measurements. 5. Graft rejection in the xenogeneic cat-dog system can be significantly delayed by ALG pretreatment. 6. The beneficial effect of blood transfusion described in different clinical and experimental studies could not be found after pretreatment of dogs with fox red blood cells. (orig.)

  3. Artificial Intelligence (AI techniques to analyze the determinants attributes in housing prices

    Directory of Open Access Journals (Sweden)

    Julia M. Núñez Tabale

    2016-12-01

    Full Text Available The econometric approach to obtain the value of a property began with hedonic modelling, which were based on a set of property attributes, internal or external, associated to each particular dwelling. The final sale value can be estimated, and also the marginal prices of each exogenous explanatory variable. A good alternative to the hedonic approach is based on several Artificial Intelligence (AI techniques, such as artificial neural networks (ANN, these tend to be more precise. Both methodologies are compared, and a case study is developed using data from Seville, the larger town in the South of Spain.

  4. High speed resonant frequency determination applied to field mapping using perturbation techniques

    International Nuclear Information System (INIS)

    Smith, B.H.; Burton, R.J.; Hutcheon, R.M.

    1992-01-01

    Perturbation techniques are commonly used for measuring electric and magnetic field distributions in resonant structures. A field measurement system has been assembled using a Hewlett Packard model 8753C network analyzer interfaced via an HPIB bus to a personal computer to form an accurate, rapid and flexible system for data acquisition, control, and analysis of such measurements. Characterization of long linac structures (up to 3 m) is accomplished in about three minutes, minimizing thermal drift effects. This paper describes the system, its application and its extension to applications such as confirming the presence of weak, off-axis quadrupole fields in an on-axis coupled linac. (Author) 5 figs., 10 refs

  5. Analytical techniques for the determination of radiochemical purity of radiopharmaceuticals prepared from kits. Pt. III

    International Nuclear Information System (INIS)

    McLean, J.R.; Rockwell, L.J.; Welsh, W.J.

    1982-01-01

    The evaluation of efficacy of commercially available kits used for the preparation of radiopharmaceuticals is one aspect of the Radiation Protection Bureau's radiopharmaceutical quality control program. This report describes some of the analytical methodology employed in the program. The techniques may be of interest to hospital radiopharmacy personnel since many of the tests can be performed rapidly and with a minimum of special equipment, thus enabling the confirmation of radiopharmaceutical purity prior to patient administration. Manufacturers of kits may also be interested in learning of the analytical methods used in the assessment of their products

  6. Bulk moisture determination in building materials by fast neutron/gamma technique

    International Nuclear Information System (INIS)

    Padron Diaz, I.; Felipe Desdin, L.; Martin Hernandez, G.; Shtejer, K.; Perez Tamayo, N.; Ceballos, C.; Lemus, O.

    1998-01-01

    Fast Neutron/Gamma Transmission technique has been improved to allow to measure moisture content in building materials. In order to improve fast neutron/gamma discrimination in the transmission system employing the NE-213 scintillation detector a pulse shape discrimination system was constructed at the CEADEN. A separate neutron/gamma detection approach was used with neutron transmission measurement using an Am-Be neutron source and a BF 3 detector and gamma transmission measurement using a collimated 137 Cs source and a NaI scintillator

  7. Analytical techniques for the determination of radiochemical purity of radiopharmaceuticals prepared from kits

    International Nuclear Information System (INIS)

    McLean, J.R.; Rockwell, L.J.; Welsh, W.J.

    1977-01-01

    The evaluation of efficacy of commercially available kits used for the preparation of radiopharmaceuticals is one aspect of the Radiation Protection Bureau's radiopharmaceutical quality control program. This report describes some of the analytical methodology employed in the program. The techniques may be of interest to hospital radiopharmacy personnel as many of the tests can be performed rapidly and with a minimum of special equipment, thus enabling the confirmation of radiopharmaceutical purity prior to patient administration. Manufacturers of kits may also be interested in learning of the analytical methods used in the assessment of their products. (auth)

  8. Determination of Fluorine and other light elements in Syrian teeth by PIGE and PIXE techniques

    International Nuclear Information System (INIS)

    Bakraji, E.; Ahmad, M.; Doueer, M.

    2013-01-01

    The aim of this study is to determine the concentration of Fluorine in Syrian teeth collected from Southern and Coastal regions where both populations have almost similar dietary habits and similar occupational activities. The conventional PIGE method is used to determine Fluorine concentration in human teeth since its play an important role in bony and dental tissues, the low levels of Fluorine can play positive role against teeth cariosity and an inhibitor against certain enzyme systems, where high levels can cause dental Fluorosis and bone abnormalities for the bone structure. Several cations and anions have been studied in the drinking water of studied areas in order to investigate the role played by these elements and whether fluoridation within the normal levels of worldwide standard grading. Na, Mg, P and Ca concentrations have been determined in studied samples in order to compare with earlier works. (author)

  9. Detached Bridgman Growth of Germanium and Germanium-Silicon Alloy Crystals

    Science.gov (United States)

    Szofran, F. R.; Volz, M. P.; Schweizer, M.; Cobb, S. D.; Motakef, S.; Croell, A.; Dold, P.; Curreri, Peter A. (Technical Monitor)

    2002-01-01

    Earth based experiments on the science of detached crystal growth are being conducted on germanium and germanium-silicon alloys (2 at% Si average composition) in preparation for a series of experiments aboard the International Space Station (ISS). The purpose of the microgravity experiments includes differentiating among proposed mechanisms contributing to detachment, and confirming or refining our understanding of the detachment mechanism. Because large contact angle are critical to detachment, sessile drop measurements were used to determine the contact angles as a function of temperature and composition for a large number of substrates made of potential ampoule materials. Growth experiments have used pyrolytic boron nitride (pBN) and fused silica ampoules with the majority of the detached results occurring predictably in the pBN. The contact angles were 173 deg (Ge) and 165 deg (GeSi) for pBN. For fused silica, the contact angle decreases from 150 deg to an equilibrium value of 117 deg (Ge) or from 129 deg to an equilibrium value of 100 deg (GeSi) over the duration of the experiment. The nature and extent of detachment is determined by using profilometry in conjunction with optical and electron microscopy. The stability of detachment has been analyzed, and an empirical model for the conditions necessary to achieve sufficient stability to maintain detached growth for extended periods has been developed. Results in this presentation will show that we have established the effects on detachment of ampoule material, pressure difference above and below the melt, and silicon concentration; samples that are nearly completely detached can be grown repeatedly in pBN.

  10. Numerical study on determining formation porosity using a boron capture gamma ray technique and MCNP.

    Science.gov (United States)

    Liu, Juntao; Zhang, Feng; Wang, Xinguang; Han, Fei; Yuan, Zhelong

    2014-12-01

    Formation porosity can be determined using the boron capture gamma ray counting ratio with a near to far detector in a pulsed neutron-gamma element logging tool. The thermal neutron distribution, boron capture gamma spectroscopy and porosity response for formations with different water salinity and wellbore diameter characteristics were simulated using the Monte Carlo method. We found that a boron lining improves the signal-to-noise ratio and that the boron capture gamma ray counting ratio has a higher sensitivity for determining porosity than total capture gamma. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Determining of electron temperature profile on the cross section of a Tokamak, using ECE technique

    Directory of Open Access Journals (Sweden)

    M. Hosseinpour

    2007-06-01

    Full Text Available  In this paper we have used plasma electron cyclotron emissions at the second harmonic frequency of extraordinary mode to determine the temperature profile of the plasma produced in IR-T1 Tokamak. The emissions obtained at different frequencies by a 5-channel heterodyne receiver, have been analyzed to determine the spatial variation of the electron temperature on the plasma cross section. The results have been also used to show the three-dimensional time evolution of the temperature profile during the period of confinement.

  12. Determination of filtration velocity and direction of groundwater flow using tracer technique, Port Dickson, Negeri Sembilan

    International Nuclear Information System (INIS)

    Md Shahid Ayub; Roslan Mohd Ali; Kamarudin Samuding

    1996-01-01

    The filtration velocity of the groundwater was determine by introducing I mCi Br-82 into a borehole. Br-82 was in the form of potassium bromide. The result showed that the filtration velocity varies from 2.3 to 4.5 cm/day depending on the soil matrix with the clayey layer posting more resistance to flow. Au-198 in the form of aurium chloride was introduce into two other boreholes to determine the direction of flow. The general trend of flow was in the direction between N140E and N160E

  13. Experimental determination of liquidus of Fe-Zr by spot technique

    International Nuclear Information System (INIS)

    Ramakrishna, P.; Samanta, B.; Balakrishnan, S.

    2016-01-01

    Metallic fuel alloy for fast reactor mainly consist of U-Pu-Zr housed in T91 clad. Study of thermophysical properties of fuel element and cladding material is vital for the fuel designer to optimize the design feature and predict the fuel behavior under reactor operating conditions.To understand the fuel-clad interaction the phase diagram study of Fe-Zr system is very important since future reactors use U-Pu-Zr alloy as fuel and stainless steel as clad. The eutectic temperature in Fe-Zr alloy system has been established experimentally by various methods. Information on the liquidus temperatures of Fe-Zr is scanty in the literature excepting a very few experimental measurements. Hence measurement of liquidus temperatures is very essential to establish the phase diagram. Present work concentrates more on the generation of liquidus data of Fe-Zr binary alloy system by Spot-technique. This is one among the advanced techniques for measuring the solid-liquid phase transition temperatures. (author)

  14. Development of image analysis for graphite pore-structure determination using fluorescence techniques

    International Nuclear Information System (INIS)

    Stephen, W.J.; Bowden, E.A.T.; Wickham, A.J.

    1983-03-01

    The use of image analysis to assess the pore structure of graphite has been developed to the point at which it may be considered available for routine use. A definitive pore structure in terms of the geometry-independent ''characteristic pore dimension'' is derived from the computer analysis of polished specimens whose open-pore structure has been impregnated with bismuth or a fluorescent epoxy resin, with the very small pores identified separately by mercury porosimetry as in the past. The pore-size distributions obtained from these combined techniques have been used successfully to predict the corrosion rates of nine graphites, of widely differing pore structure, in a variety of gas compositions and, indirectly, to confirm appropriate mean ranges and rate constants for the reaction of the oxidising species in these gas mixtures. The development of the fluorescent-impregnant technique is discussed in detail and its use is justified in preference to ''traditional'' methods. Further possible refinements are discussed, including the eventual aim of obtaining a computer prediction of the future oxidation behaviour of the graphite directly from the image analyser. (author)

  15. Gestational obesity as a determinant of general anesthesia technique for caesarean delivery: a case report.

    Directory of Open Access Journals (Sweden)

    José Ricardo Navarro Vargas

    2009-07-01

    Full Text Available Background. The incidence of obesity has undergone a dramatic increase around the world during the last few years. Such epidemic behavior has been associated with obstetric patient’s frequent presentation of different stages of obesity when undergoing anesthetic procedure. Obesity in pregnant women involves the risk of adverse maternal and fetal outcomes. Hypertension and preeclampsia, diabetes, fetal macrosomia, caesarean delivery, difficult airway management and neuroaxial techniques are more likely to be performed in this group of patients. Materials and methods. This is a case report of a morbid obese patient scheduled for caesarean delivery and tubal ligation. Regional, spinal and epidural techniques were attempted for surgery with unsuccessful results; this entails general anesthesia for surgery. The literature on complications due to obesity during pregnancy was reviewed, emphasising relevance for the anesthesiologist. Conclusion. Obesity, especially morbid obesity in pregnant women, represents a challenge for anesthesia management. Updated knowledge of physiology and the conditions related to obesity in pregnancy is necessary; medical services must be prepared to provide optimum and safe obstetric anesthesia, analgesia and post-operation care.

  16. The Potential for Zinc Stable Isotope Techniques and Modelling to Determine Optimal Zinc Supplementation

    Directory of Open Access Journals (Sweden)

    Cuong D. Tran

    2015-05-01

    Full Text Available It is well recognised that zinc deficiency is a major global public health issue, particularly in young children in low-income countries with diarrhoea and environmental enteropathy. Zinc supplementation is regarded as a powerful tool to correct zinc deficiency as well as to treat a variety of physiologic and pathologic conditions. However, the dose and frequency of its use as well as the choice of zinc salt are not clearly defined regardless of whether it is used to treat a disease or correct a nutritional deficiency. We discuss the application of zinc stable isotope tracer techniques to assess zinc physiology, metabolism and homeostasis and how these can address knowledge gaps in zinc supplementation pharmacokinetics. This may help to resolve optimal dose, frequency, length of administration, timing of delivery to food intake and choice of zinc compound. It appears that long-term preventive supplementation can be administered much less frequently than daily but more research needs to be undertaken to better understand how best to intervene with zinc in children at risk of zinc deficiency. Stable isotope techniques, linked with saturation response and compartmental modelling, also have the potential to assist in the continued search for simple markers of zinc status in health, malnutrition and disease.

  17. Sensitivity of diagnostic techniques in determining the prevalence of anuran trypanosomes.

    Science.gov (United States)

    Woo, P T

    1983-01-01

    Two hundred thirty-three leopard frogs (Rana pipiens) from Oshkosh, Wisconsin, USA, were divided into two groups and their blood examined for trypanosomes. In Group I (n = 157), where the blood was examined by the hematocrit centrifuge technique (HCT), 36 (23%) were infected with trypanosomes. Eighteen were infected with Trypanosoma pipientis, 13 with Trypanosoma ranarum, three with Trypanosoma rotatorium and two with mixed infections of T. pipientis and T. ranarum. In Group II (n = 76) the blood was cultured and also examined by HCT and wet mounts. Trypanosomes (T. pipientis and T. ranarum) were detected in 24 frogs (33%) using all three techniques. Eleven T. pipientis were detected by HCT, however none by culture and two by wet mounts. Twelve T. ranarum were detected by culture while only 10 were found by HCT and five by wet mounts. One T. ranarum infection detected by HCT was missed by culture because of bacterial contamination. The HCT was consistently better than wet mount examinations. It is suggested that the HCT be used whenever possible in future trypanosome surveys.

  18. Determination of trace elements in petroleum products by inductively coupled plasma techniques: A critical review

    International Nuclear Information System (INIS)

    Sánchez, Raquel; Todolí, José Luis; Lienemann, Charles-Philippe; Mermet, Jean-Michel

    2013-01-01

    The fundamentals, applications and latter developments of petroleum products analysis through inductively coupled plasma optical emission spectrometry (ICP-OES) and mass spectrometry (ICP-MS) are revisited in the present bibliographic survey. Sample preparation procedures for the direct analysis of fuels by using liquid sample introduction systems are critically reviewed and compared. The most employed methods are sample dilution, emulsion or micro-emulsion preparation and sample decomposition. The first one is the most widely employed due to its simplicity. Once the sample has been prepared, an organic matrix is usually present. The performance of the sample introduction system (i.e., nebulizer and spray chamber) depends strongly upon the nature and properties of the solution finally obtained. Many different devices have been assayed and the obtained results are shown. Additionally, samples can be introduced into the plasma by using an electrothermal vaporization (ETV) device or a laser ablation system (LA). The recent results published in the literature showing the feasibility, advantages and drawbacks of latter alternatives are also described. Therefore, the main goal of the review is the discussion of the different approaches developed for the analysis of crude oil and its derivates by inductively coupled plasma (ICP) techniques. - Highlights: • Analysis of petroleum products by inductively coupled plasma techniques is revisited. • Fundamental studies are included together with reports dealing with applications. • Conventional and non-conventional sample introduction methods are considered. • Sample preparation methods are critically compared and described

  19. Solicitation of HPLC and HPTLC Techniques for Determination of Rutin from Polyalthia longifolia Thwaites

    Science.gov (United States)

    Doshi, Gaurav Mahesh; Zine, Sandeep Prabhakar; Chaskar, Pratip Kashinath; Une, Hemant Devidas

    2014-01-01

    Background: Polyalthia longifolia Thwaites is an important traditional plant in India. Rutin, an active constituent has been reported to possess good amount of pharmacological as well as therapeutic potential. Objective: The aim of the present study was to find out by analytical techniques how much percentage of rutin is present in the plant leaves’ ethanolic extract by analytical techniques. Materials and Methods: Shade dried leaves of Polyalthia longifolia were subjected to cold ethanolic extraction followed by monitoring the isolated rutin high-pressure liquid chromatography (HPLC) and high performance thin layer chromatography (HPTLC) after carrying out preliminary phytochemical screening. Results: Extraction yield was found to be 13.94% w/w. Phytochemical screening of the extract showed the presence of flavonoids, steroids, diterpenoids, alkaloids, saponins, tannins and phenolic compounds and mucilage. From the Rf value, the ethanolic extract was found to be having constituent identical to rutin. By HPTLC and HPLC the amount of rutin was found to be 11.60% w/w and 4.03% w/v, respectively. Conclusion: The active constituent isolated was found to be equal to rutin. PMID:25002804

  20. The Potential for Zinc Stable Isotope Techniques and Modelling to Determine Optimal Zinc Supplementation

    Science.gov (United States)

    Tran, Cuong D.; Gopalsamy, Geetha L.; Mortimer, Elissa K.; Young, Graeme P.

    2015-01-01

    It is well recognised that zinc deficiency is a major global public health issue, particularly in young children in low-income countries with diarrhoea and environmental enteropathy. Zinc supplementation is regarded as a powerful tool to correct zinc deficiency as well as to treat a variety of physiologic and pathologic conditions. However, the dose and frequency of its use as well as the choice of zinc salt are not clearly defined regardless of whether it is used to treat a disease or correct a nutritional deficiency. We discuss the application of zinc stable isotope tracer techniques to assess zinc physiology, metabolism and homeostasis and how these can address knowledge gaps in zinc supplementation pharmacokinetics. This may help to resolve optimal dose, frequency, length of administration, timing of delivery to food intake and choice of zinc compound. It appears that long-term preventive supplementation can be administered much less frequently than daily but more research needs to be undertaken to better understand how best to intervene with zinc in children at risk of zinc deficiency. Stable isotope techniques, linked with saturation response and compartmental modelling, also have the potential to assist in the continued search for simple markers of zinc status in health, malnutrition and disease. PMID:26035248

  1. Full-field stress determination in photoelasticity with phase shifting technique

    Science.gov (United States)

    Guo, Enhai; Liu, Yonggang; Han, Yongsheng; Arola, Dwayne; Zhang, Dongsheng

    2018-04-01

    Photoelasticity is an effective method for evaluating the stress and its spatial variations within a stressed body. In the present study, a method to determine the stress distribution by means of phase shifting and a modified shear-difference is proposed. First, the orientation of the first principal stress and the retardation between the principal stresses are determined in the full-field through phase shifting. Then, through bicubic interpolation and derivation of a modified shear-difference method, the internal stress is calculated from the point with a free boundary along its normal direction. A method to reduce integration error in the shear difference scheme is proposed and compared to the existing methods; the integration error is reduced when using theoretical photoelastic parameters to calculate the stress component with the same points. Results show that when the value of Δx/Δy approaches one, the error is minimum, and although the interpolation error is inevitable, it has limited influence on the accuracy of the result. Finally, examples are presented for determining the stresses in a circular plate and ring subjected to diametric loading. Results show that the proposed approach provides a complete solution for determining the full-field stresses in photoelastic models.

  2. Wet effluent diffusion technique and determination of C1-C5 alcohols in air

    Czech Academy of Sciences Publication Activity Database

    Sklenská, Jana; Pařízek, Petr; Večeřa, Zbyněk

    2001-01-01

    Roč. 8, č. 1 (2001), s. 121-127 ISSN 1231-7098 R&D Projects: GA ČR GA203/98/0943 Grant - others:COPERNICUS(BE) SUB-AERO EVK2-1999-000327 Institutional research plan: CEZ:AV0Z4031919 Keywords : wet effluent difussion denuder * determination * air Subject RIV: CB - Analytical Chemistry, Separation

  3. Determination of rhenium in molybdenite by X-ray fluorescence: A combined chemical-spectrometric technique.

    Science.gov (United States)

    Solt, M W; Wahlberg, J S; Myers, A T

    1969-01-01

    Rhenium in molybdenite is separated from molybdenum by distillation of rhenium heptoxide from a perchloric-sulphuric acid mixture. It is concentrated by precipitation of the sulphide and then determined by X-ray fluorescence. From 3 to 1000 microg of rhenium can be measured with a precision generally within 2%. The procedure tolerates larger amounts of molybdenum than the usual colorimetric methods.

  4. Determination of rhenium in molybdenite by X-ray fluorescence. A combined chemical-spectrometric technique

    Science.gov (United States)

    Solt, M.W.; Wahlberg, J.S.; Myers, A.T.

    1969-01-01

    Rhenium in molybdenite is separated from molybdenum by distillation of rhenium heptoxide from a perchloric-sulphuric acid mixture. It is concentrated by precipitation of the sulphide and then determined by X-ray fluorescence. From 3 to 1000 ??g of rhenium can be measured with a precision generally within 2%. The procedure tolerates larger amounts of molybdenum than the usual colorimetric methods. ?? 1969.

  5. Spatial channel theory: A technique for determining the directional flow of radiation through reactor systems

    International Nuclear Information System (INIS)

    Williams, M.L.; Engle, W.W.

    1977-01-01

    A method is introduced for determining streaming paths through a non-multiplying medium. The concepts of a ''response continuum'' and a pseudo-particle called a contribution are developed to describe the spatial channels through which response flows from a source to a detector. An example application of channel theory to complex shield analysis is cited

  6. Microwave digestion techniques applied to determination of boron by ICP-AES in BNCT program

    International Nuclear Information System (INIS)

    Farias, Silvia S.; Di Santo, Norberto R.; Garavaglia, Ricardo N.; Pucci, Gladys N.; Batistoni, Daniel A.; Schwint, Amanda E.

    1999-01-01

    Recently, boron neutron capture therapy (BNCT) has merged as an interesting option for the treatment of some kind of tumors where established therapies show no success. A molecular boronated species, enriched in 10 B is administrated to the subject; it localizes in malignant tissues depending the kind of tumor and localization. Therefore, a very important fact in BNCT research is the detection of boron at trace or ultra trace levels precisely and accurately. This is extremely necessary as boronated species do localize in tumoral tissue and also localize in liver, kidney, spleen, skin, membranes. By this way, before testing a boronated species, it is mandatory to determine its biodistribution in a statistically meaning population, that is related with managing of a great number of samples. In the other hand, it is necessary to exactly predict when to begin the irradiation and to determine the magnitude of radiation to obtain the desired radiological dose for a specified mean boron concentration. This involves the determination of boron in whole blood, which is related with boron concentration in the tumor object of treatment. The methodology selected for the analysis of boron in whole blood and tissues must join certain characteristics: it must not be dependant of the chemical form of boron, it has to be fast and capable to determine boron accurately and precisely in a wide range of concentrations. The design and validation of experimental models involving animals in BNCT studies and the determination of boron in blood of animals and subjects upon treatment require reliable analytical procedures to determine boron quantitatively in those biologic materials. Inductively coupled plasma-atomic emission spectrometry (ICP-AES) using pneumatic nebulization is one of the most promising methods for boron analysis, but the sample must be liquid and have low solid concentration. In our case, biological tissues and blood, it is mandatory to mineralize and/or dilute samples

  7. The comparison of techniques and methods for L-ascorbic acid determination in the fruits

    Directory of Open Access Journals (Sweden)

    Cvetković Biljana R.

    2012-01-01

    Full Text Available Vitamin C is an essential vitamin for human nutrition; with the L-ascorbic acid (AA being the active form of vitamin C. Hence, determination of the L-ascorbic acid in the natural and processed foods is very important. In the past, plenty of methods based on the reversible redox reaction of AA oxidation/DHA reduction were developed. Because of L-ascorbic acid instability in aqueous solutions, it is useful to analyze various types of extraction. The aim of this study is to compare three different methods and three different extractants for the L-ascorbic acid determination. Fruits (kiwi, lemon, orange, and grapefruit were purchased from a local market. The L-ascorbic acid in these four samples was determined by the three different methods: the AOAC, the HPLC method with three different types of extractions, and the colorimetric method using ascorbate-oxidase. For the HPLC measurements, one part of the fruits was extracted with distilled water, the second with potassium hydrogen phosphate, and the third with 3% meta-phosphoric acid (MPA in 8% acetic acid. The HPLC measurements of each sample were repeated three times, the AOAC titration was repeated five times, and in the calorimetric method three measurements were performed. The results were statistically evaluated related to sample basis. Statistical analysis shows that there is a significant difference between the results for all three methods of extraction for all samples, except for the grapefruit sample where no significant difference was observed between the results obtained after the buffer extraction (E2 and the metaphosphoric acid in acetic acid extraction (E3. Discriminative analysis for the HPLC determinations proves that there is a clear difference and defined border between the samples in relation to the methods of extraction during the HPLC determination.

  8. Determination of rare earth elements in tomato plants by inductively coupled plasma mass spectrometry techniques.

    Science.gov (United States)

    Spalla, S; Baffi, C; Barbante, C; Turetta, C; Turretta, C; Cozzi, G; Beone, G M; Bettinelli, M

    2009-10-30

    In recent years identification of the geographical origin of food has grown more important as consumers have become interested in knowing the provenance of the food that they purchase and eat. Certification schemes and labels have thus been developed to protect consumers and genuine producers from the improper use of popular brand names or renowned geographical origins. As the tomato is one of the major components of what is considered to be the healthy Mediterranean diet, it is important to be able to determine the geographical origin of tomatoes and tomato-based products such as tomato sauce. The aim of this work is to develop an analytical method to determine rare earth elements (RRE) for the control of the geographic origin of tomatoes. The content of REE in tomato plant samples collected from an agricultural area in Piacenza, Italy, was determined, using four different digestion procedures with and without HF. Microwave dissolution with HNO3 + H2O2 proved to be the most suitable digestion procedure. Inductively coupled plasma quadrupole mass spectrometry (ICPQMS) and inductively coupled plasma sector field plasma mass spectrometry (ICPSFMS) instruments, both coupled with a desolvation system, were used to determine the REE in tomato plants in two different laboratories. A matched calibration curve method was used for the quantification of the analytes. The detection limits (MDLs) of the method ranged from 0.03 ng g(-1) for Ho, Tm, and Lu to 2 ng g(-1) for La and Ce. The precision, in terms of relative standard deviation on six replicates, was good, with values ranging, on average, from 6.0% for LREE (light rare earth elements) to 16.5% for HREE (heavy rare earth elements). These detection limits allowed the determination of the very low concentrations of REE present in tomato berries. For the concentrations of REE in tomato plants, the following trend was observed: roots > leaves > stems > berries. Copyright 2009 John Wiley & Sons, Ltd.

  9. Organisational justice rules as determinants of black and white employees' fairness perceptions of personnel selection techniques

    Directory of Open Access Journals (Sweden)

    Angela de Jong

    2000-06-01

    Full Text Available The diversity of the South African population may lead to opinions that test fairness is not a pure empirical problem, but requires certain subjective value judgements. The aim of this study was to identify applicants' underlying reasons for evaluating a selection technique as being fair/unfair. These fairness perceptions were analysed by means of the organisational justice theory. The total sample consisted of 328 mature university students (M = 30,6 all of whom had work experience. The analyses comprised two sets of comparisons. The first set involved Black (uninformed and White (uninformed groups. The second comparison involved informed versus uninformed black students. Exposure to the subjects Strategic Personnel Management and/or undergraduate Industrial Psycohology, in which the nature and value of various selection techniques are studied, constituted the variable'being informed'. It was hypothesised that the Black (uninformed and the White (uninformed groups would perceive the value of the 11 justice rules for the total fairness perception across the ten selection techniques differently. Substantial support was found for this hypothesis. The same hypothesis was investigated for the Black (informed and the Black (uninformed groups, but no significant differences were found to support the latter hypothesis. The implications of these findings are discussed in terms of South African selection practices. Opsomming Die diversiteit van die Suid-Afrikaanse bevolking mag daartoe lei dat persepsies van die billikheid van verskillende personeelkeuringtegnieke op n verskeidenheid van subjektiewe waarde-oordele gegrond word. Dit is die doel van hierdie ondersoek om die onderliggende redes waarvolgens kandidate keuringtegnieke as billik/onbillik evalueer, te identifiseer. Die kandidate se billikheidpersepsies van tien keuringtegnieke is aan die hand van die organisatoriese billikheidteorie ontleed. Die steekproef het bestaan uit 328 volwasse

  10. Neutron and gamma-ray transmission technique for the on-line determination of moisture in coal and coke

    International Nuclear Information System (INIS)

    Sowerby, B.D.; Millen, M.J.; Rafter, P.T.

    1985-01-01

    A fast neutron and gamma-ray transmission technique is being developed for the on-line analysis of moisture in coal and coke. The technique utilises 252 Cf and 137 Cs sources and 3 He and NaI(Tl) detectors. Laboratory measurements on single coal samples have shown that moisture can be determined to better than 1 wt% over the range 0 to 16 wt% moisture and 5 to 17cm thickness. Reduced errors were obtained for restricted ranges of moisture and thickness. Preliminary measurements on coke of thickness 30 to 50cm have shown that moisture can be determined to within 0.26 wt% over the range 1 to 16 wt% moisture

  11. Determination of photophysical parameters of cyanines using different techniques. Application to DODCI (3-3' dietiloxacarbocyanine iodide)

    International Nuclear Information System (INIS)

    Duchowicz, R.; Scaffardi, L.; Di Paolo, R.E.; Tocho, J.O.

    1990-01-01

    A number of fluorescence and absorption techniques were developed for the determination of photo-physical parameters of photo-isomerizable cyanines. The application of these techniques, such as saturated fluorescence, double excitation fluorescence and temperature dependent absorption, to the specific case of 3-3' dietiloxadicarbocyanine iodide (DODCI), allowed the particular study of photo-isomer's exited state along with its decay processes. Fluorescence efficiency and the mean life of the photo-isomer as a function of temperature were obtained. The activation energy and the pre-exponential factor for the non-radioactive decay processes were determined. For the first time, the fluorescence spectrum of the transient isomer form was registered free of the emission of the normal species. (Author). 6 refs., 9 figs

  12. Trends in preconcentration procedures for metal determination using atomic spectrometry techniques

    International Nuclear Information System (INIS)

    Godoi Pereira, M. de; Arruda, M.A.Z.

    2003-01-01

    Methods for metal preconcentration are often described in the literature. However, purposes are often different, depending on whether the methods are applied in environmental, clinical or technological fields. The respective method needs to be efficient, give high sensitivity, and ideally also is selective which is useful when used in combination with atomic spectroscopy. This review presents the actual tendencies in metal preconcentration using techniques such as flame atomic absorption spectrometry (FAAS), electrothermal atomic absorption spectrometry (ETAAS), hydride generation atomic absorption spectrometry (HGAAS), inductively coupled plasma optical emission spectrometry (ICP OES) and inductively coupled plasma mass spectrometry (ICP-MS). Procedures based on related to electrochemical, coprecipitation/precipitation, liquid-liquid and solid-liquid extraction and atom trapping mechanisms are presented. (author)

  13. Determination of trace element contents in grass samples for cattle feeding using NAA techniques

    Energy Technology Data Exchange (ETDEWEB)

    Yusof, Alias Mohamad; Jagir Singh, Jasbir Kaur

    1987-09-01

    An investigation on trace elements contents in six types of grass samples used for cattle feeding have been carried out using NAA techniques. The grass samples, Mardi Digit, African Star, Signal, Guinea, Setaria and Setaria Splendida were found to contain at least 19 trace elements in varying concentrations. The results were compared to the figures obtained from available sources to ascertain the status as to whether the grass samples studied would satisfy the minimum requirements of trace elements present in grass for cattle feeding or otherwise. Preference made on the suitability of the grass samples for cattle feeding was based on the availability and abundance of the trace elements, taking into account factors such as the degree of toxicity, inadequate amounts and contamination due to the presence of other trace elements not essential for cattle feeding.

  14. Determination of trace element contents in grass samples for cattle feeding using NAA techniques

    International Nuclear Information System (INIS)

    Alias Mohamad Yusof; Jasbir Kaur Jagir Singh

    1987-01-01

    An investigation on trace elements contents in six types of grass samples used for cattle feeding have been carried out using NAA techniques. The grass samples, Mardi Digit, African Star, Signal, Guinea, Setaria and Setaria Splendida were found to contain at least 19 trace elements in varying concentrations. The results were compared to the figures obtained from available sources to ascertain the status as to whether the grass samples studied would satisfy the minimum requirements of trace elements present in grass for cattle feeding or otherwise. Preference made on the suitability of the grass samples for cattle feeding was based on the availability and abundance of the trace elements, taking into account factors such as the degree of toxicity, inadequate amounts and contamination due to the presence of other trace elements not essential for cattle feeding. (author)

  15. Radioanalytical determination of plutonium and americium using ion exchange and extraction chromatography technique in urine

    International Nuclear Information System (INIS)

    Santhanakrishnan, V.; Sreedevi, K.R.; Rajaram, S.; Ravi, P.M.

    2011-01-01

    The use of anion exchange chromatography for the separation of Pu and extraction chromatography technique for the separation of Am from urine samples was studied. In the earlier method, Pu separation was carried out by anion exchange chromatography followed by Am separation by cation exchange chromatography. The chemical recovery of Am obtained by cation exchange separation method was inconsistent and low in the range 30-70%. In this study, the average Pu recovery obtained using anion exchange chromatography was 89.2 with standard deviation of 10.4 and the average Am recovery obtained using extraction chromatography with TRU resin was 77.4 with standard deviation of 14.8. Moreover, Am separation could be completed within three hours using the TRU column compared to two days that were required for the cation exchange chromatography. (author)

  16. Radioactive or natural tracer techniques for leak determining of dam abutment

    International Nuclear Information System (INIS)

    Chen Jiansheng; Du Guoping; Zheng Zheng; Sun Jing

    1995-01-01

    Infiltration and localization of preferential infiltration zones at the dam abutment are measured using radioactive tracer tests of flow in boreholes, meanwhile interconnection between boreholes and the observing water points is analysed. The theory and practice of radioactive tracer synthetic detective method are described to give methods and calculation formulae used under the condition of stable flow in single well to measure permeability coefficient and hydrostatic heads. Major single hole techniques including measurement for seepage line, velocity, rate of seepage flow and relationship of recharge of groundwater in aquifers are introduced briefly. The possibilities offered by natural tracers are analysed, including electric-conduct, ph-value and temperature of water as well as stable isotopes (D, 18 O) and tritium. Furthermore, the sensibilities of this theory and methods were confirmed by detecting seepage flow field of Xinanjiang Dam

  17. [Quantitative determination of glass content in monazite glass-ceramics by IR technique].

    Science.gov (United States)

    He, Yong; Zhang, Bao-min

    2003-04-01

    Monazite glass-ceramics consist of both monazite and metaphoshate glass phases. The absorption bands of both phases do not overlap each other, and the absorption intensities of bands 1,275 and 616 cm-1 vary with the glass contents. The correlation coefficient between logarithmic absorbance ratio of the two bands and glass contents was r = 0.9975 and its regression equation was y = 48.356 + 25.93x. The absorbance ratio of bands 952 and 616 cm-1 also varied with different ratios of Ce2O3/La2O3 in synthetic monazites, with r = 0.9917 and a regression equation y = 0.2211 exp (0.0221x). High correlation coefficients show that the IR technique could find new application in the quantitative analysis of glass content in phosphate glass-ceramics.

  18. Trace uranium determination in beverages and mineral water using fission track techniques

    International Nuclear Information System (INIS)

    Cheng, Y.L.; Lin, J.Y.; Hao, X.H.

    1993-01-01

    The uranium contents of beverages and mineral water have been estimated using the technique of fission track analysis with polycarbonate detector. The U contents in beverages have been found to vary from 0.26 ± 0.03 to 1.65 ± 0.07 ppb, the average value is 0.93 ± 0.05 ppb. The mean U content in mineral water is 9.20 ± 0.16 ppb, which is ∼ 10 times higher than the mean U content of beverages. The present study shows the high U content in mineral water, indicating need for further investigation of U content in mineral water for the studies of radiation health hazards. (Author)

  19. Mortar and surface dating with Optically Stimulated Luminescence (OSL): Innovative techniques for the age determination of buildings

    International Nuclear Information System (INIS)

    Panzeri, L.

    2013-01-01

    In this work the results of a dating study on bricks and mortars using both Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) are shown. The samples came from the outside walls of the Certosa di Pavia, located in northern Italy and independently dated (XVII-XVIII century). TL dating, applied to bricks using the fine grain technique, allowed to determine the time of manufacture of the bricks (XII century), that resulted therefore re-used. To circumvent this problem the application of two innovative dating techniques, OSL surface dating and mortar dating, was attempted. The first was applied to the light-shielded surfaces of bricks and allowed to successfully determine the edification of the wall (XVII century). Mortar dating gave instead severe age overestimation: the results obtained on coarse grain quartz with the SAR technique both on multi-grains aliquots and with single-grain analyses were highly dispersed indicating an incomplete bleaching of the quartz grains. The shine-down curves were in fact characterized by the absence of the so-called fast component, as confirmed by Linear Modulated OSL technique.

  20. Determination of the optimal method for the field-in-field technique in breast tangential radiotherapy

    International Nuclear Information System (INIS)

    Tanaka, Hidekazu; Hayashi, Shinya; Hoshi, Hiroaki

    2014-01-01

    Several studies have reported the usefulness of the field-in-field (FIF) technique in breast radiotherapy. However, the methods for the FIF technique used in these studies vary. These methods were classified into three categories. We simulated a radiotherapy plan with each method and analyzed the outcomes. In the first method, a pair of subfields was added to each main field: the single pair of subfields method (SSM). In the second method, three pairs of subfields were added to each main field: the multiple pairs of subfields method (MSM). In the third method, subfields were alternately added: the alternate subfields method (ASM). A total of 51 patients were enrolled in this study. The maximum dose to the planning target volume (PTV) (Dmax) and the volumes of the PTV receiving 100% of the prescription dose (V100%) were calculated. The thickness of the breast between the chest wall and skin surface was measured, and patients were divided into two groups according to the median. In the overall series, the average V100% with ASM (60.3%) was significantly higher than with SSM (52.6%) and MSM (48.7%). In the thin breast group as well, the average V100% with ASM (57.3%) and SSM (54.2%) was significantly higher than that with MSM (43.3%). In the thick breast group, the average V100% with ASM (63.4%) was significantly higher than that with SSM (51.0%) and MSM (54.4%). ASM resulted in better dose distribution, regardless of the breast size. Moreover, planning for ASM required a relatively short time. ASM was considered the most preferred method. (author)

  1. Advances in modern sample preparation techniques using microwaves assisted chemistry for metal species determination (W1)

    International Nuclear Information System (INIS)

    Ponard, O.F.X.

    2002-01-01

    Full text: Sample preparation has long been the bottleneck of environmental analysis for both total and species specific analysis. Digestion, extraction and preparation of the analytes are relying on a series of chemical reactions. The introduction of microwave assisted sample preparation has first been viewed as a mean to accelerate the kinetics of digestion of the matrix for total elements and fast samples preparation procedures. However, the extensive development and success of microwave digestion procedures in total elemental analysis has now allowed to have a larger insight of the perspectives offered by this technique. Microwave technologies now offer to have a precise control of the temperature and indirectly control the reaction kinetics taking place during the sample preparation procedures. Microwave assisted chemistry permits to perform simultaneously the fundamental steps required for metal species extraction and derivatization. The number of sample preparation steps used for organotin or organomercury species have been reduced to one and the total time of sample preparation brought down for a few hours to some minutes. Further, the developments of GC/ICP/MS techniques allow to routinely use speciated isotopic dilution methods has internal probe of the chemical reactions. These new approaches allow us to use the addition of the labeled species for isotopic dilution as a mean to evaluate and follow the chemical processes taking place during the extraction procedure. These procedures will help us to understand and check for the stability of the analytes during the chemistry of the sample preparation procedure and bring some insights of the chemistry taking place during the extraction. Understanding the different mechanisms involved in the sample preparation steps will allow us in return to further improve all theses procedures and bring us to the horizon of 'on-line sample preparation and detection'. (author)

  2. A two-crown finite element technique for the determination of tearing modulus

    International Nuclear Information System (INIS)

    Suo, X.Z.; Combescure, A.

    1989-01-01

    The importance of approach to the subject of crack instability for the design of structures containing cracks has increased considerably over the last few years. The tearing modulus theory recently enunciated by Paris and co-workers has emerged as one of the leading criterions for stable crack growth and for instability, and the estimation of T termed Tearing modulus in the theory has since been extensively investigated theoretically as well as experimentally. Analytical methods exist for calculating the tearing modulus of various crack configurations in simple-shaped structures under certain loading conditions. However, for arbitrary structures under general loading, more sophisticated calculation techniques are required. Extending the virtual crack extension method introduced independently by Hellen and Parks, a new numerical approach for calculating the tearing modulus is presented hereafter and put in a form suitable for the instability analysis of structures containing one single crack or several interacting cracks. As it is well-known that the calculation of the energy release rate in elasticity by the virtual crack extension method is related to a stiffness derivative to which only a small region around the crack tip has a contribution, the technique described in the paper shows that it would be reasonable to evaluate the tearing modulus, or rather, the second derivative of potential energy with respect to the crack length, by means of two stiffness derivative calculations in two crowns around the crack tip. In particular, when one crown is strictly included in another one, computation is largely curtailed at this point with some saving of computer time, but a very accurate value of tearing modulus is obtained. As an interesting consequence, an another expression of the tearing modulus is carried out. In Section 4: the classical tearing modulus is proved to be precisely equivalent to a line integral which is independent of integration path. Numerical example

  3. Facile and Sensitive Spectrophotometric Technique for the Determination of Carbofuran in its Formulations, Water and Grain Samples with Substituted Anilines

    Directory of Open Access Journals (Sweden)

    V. Harikishna

    2005-01-01

    Full Text Available Methods are described for the determination of carbofuran in its formulations, in water and grain samples by the diazotization coupling spectrophotometric technique, using substituted anilines such as 4-bromoaniline, 4-methylaniline and 4-aminobenzaldehyde as the coupling agents. The orange red colour formed with 4-bromoaniline shows maximum absorption at 478 nm, yellow colour obtained with 4-methylaniline have maximum absorption at 465 nm whereas a red colour derivative formed with 4-aminobenzaldehyde shows λmax at 472 nm. The methods could be successfully applied for the determination of carbofuran in its formulations, water and grain samples.

  4. Determination of protein by resonance light scattering technique using dithiothreitol-sodium dodecylbenzene sulphonate as probe

    Science.gov (United States)

    Wu, Lihang; Mu, Dan; Gao, Dejiang; Deng, Xinyu; Tian, Yuan; Zhang, Hanqi; Yu, Aimin

    2009-02-01

    The resonance light scattering (RLS) spectra of bovine serum albumin (BSA)-dithiothreitol (DTT)-sodium dodecylbenzene sulphonate (SDBS) and its analytical application were investigated. The RLS intensity of this system can be effectively enhanced in the presence of BSA. Based on the enhanced RLS intensity, a simple assay for BSA was developed. The experimental results indicate that the enhanced RLS intensity is proportional to the concentration of BSA in the range from 1.0 × 10 -8 to 7.5 × 10 -7 mol L -1 with the determination limit of 5.0 × 10 -9 mol L -1. The effects of pH, concentration of SDBS and DTT on the RLS enhancement were discussed. Most metal ions have little interference on the determination of BSA. Some synthetic and real samples were analyzed, and the results obtained were in good agreement with those obtained by Bradford method.

  5. Radioisotope dilution technique for determination of vitamin B12 in foods

    International Nuclear Information System (INIS)

    Casey, P.J.; Speckman, K.R.; Ebert, F.J.; Hobbs, W.E.

    1982-01-01

    A radioisotope dilution (RID) method for the determination of vitamin B 12 is presented. The method combines a standard extraction procedure (AOAC 43.108, 12th ed.) with a commercially available RID assay kit. The method was evaluated on a wide range of fortified and unfortified food products. Recovery studies on both groups yielded average recoveries of 98.1 and 95.8%, respectively. Reproducibility data generated from replicate analysis on both groups gave a relative standard deviation of 6.9% for the fortified group and 9.2% for the unfortified group. For the samples studied, the mean vitamin B 12 content determined by the RID method was 8.01 μ/100 g vs a mean of 7.54 μg/100 g by the AOAC microbiological method; the correlation coefficient was r = 0.983

  6. A pyroloysis technique for determining microamounts of hydrogen in lunar soil using the helium ionization detector

    Science.gov (United States)

    Bustin, R.

    1983-01-01

    A method has been developed which will determine hydrogen in sub-milligram samples of lunar soil. It consists of heating the sample in a pyroprobe followed by the gas chromatographic determination of hydrogen using the helium ionization detector. Using a 7 foot, 1/8 OD stainless steel column packed with Carbosieve S, 120/140 mesh, hydrogen was well-separated from the other gases released from lunar soil. Standards of hydrogen in helium were used for calibration. The limit to detection under the conditions used was about 2 ng. The method was linear from 2 ng to 270 ng. The method was checked using some actual lunar samples. Results were typical of those obtained for lunar soils using other methods.

  7. Reduction of Under-Determined Linear Systems by Sparce Block Matrix Technique

    DEFF Research Database (Denmark)

    Tarp-Johansen, Niels Jacob; Poulsen, Peter Noe; Damkilde, Lars

    1996-01-01

    numerical stability of the aforementioned reduction. Moreover the coefficient matrix for the equilibrium equations is typically very sparse. The objective is to deal efficiently with the full pivoting reduction of sparse rectangular matrices using a dynamic storage scheme based on the block matrix concept.......Under-determined linear equation systems occur in different engineering applications. In structural engineering they typically appear when applying the force method. As an example one could mention limit load analysis based on The Lower Bound Theorem. In this application there is a set of under......-determined equilibrium equation restrictions in an LP-problem. A significant reduction of computer time spent on solving the LP-problem is achieved if the equilib rium equations are reduced before going into the optimization procedure. Experience has shown that for some structures one must apply full pivoting to ensure...

  8. Determination of Mercury in an Assortment of Dietary Supplements Using an Inexpensive Combustion Atomic Absorption Spectrometry Technique

    OpenAIRE

    Levine, Keith E.; Levine, Michael A.; Weber, Frank X.; Hu, Ye; Perlmutter, Jason; Grohse, Peter M.

    2005-01-01

    The concentrations of mercury in forty, commercially available dietary supplements, were determined using a new, inexpensive analysis technique. The method involves thermal decomposition, amalgamation, and detection of mercury by atomic absorption spectrometry with an analysis time of approximately six minutes per sample. The primary cost savings from this approach is that labor-intensive sample digestion is not required prior to analysis, further automating the analytical procedure. As a res...

  9. Machine-learning techniques for family demography: an application of random forests to the analysis of divorce determinants in Germany

    OpenAIRE

    Arpino, Bruno; Le Moglie, Marco; Mencarini, Letizia

    2018-01-01

    Demographers often analyze the determinants of life-course events with parametric regression-type approaches. Here, we present a class of nonparametric approaches, broadly defined as machine learning (ML) techniques, and discuss advantages and disadvantages of a popular type known as random forest. We argue that random forests can be useful either as a substitute, or a complement, to more standard parametric regression modeling. Our discussion of random forests is intuitive and...

  10. A radiochemical technique for the determination of mercury in drinking water

    International Nuclear Information System (INIS)

    Ahmad, S.; Chaudhri, M.S.; Qureshi, I.H.

    1982-01-01

    A radiochemical method for the separation and determination of mercury in drinking water has been developed. The radionuclides of mercury formed after neutron irradiation of the sample were separated by liquid/liquid extraction using PAN and TBA mixture in chloroform from aqueous nitric acid medium. Quantitative extraction of mercury was achieved in a single step and the equilibrium was attained within five minutes. (orig.)

  11. Determination of the pr of laser fusion targets using the α-particle TOF technique

    International Nuclear Information System (INIS)

    Slivinsky, V.W.; Lent, E.; Shay, H.D.; Manes, K.R.

    1975-01-01

    A computer code was written to describe the alpha particle energy loss. The problem of a symmetric compression of the DT gas by an exploding microsphere is analyzed. The code calculates the energy spectrum of a Gaussian distribution of alpha particles after passing through the compressed gas and the exploded glass. The calculations are being used to determine design parameters for diagnostic instruments for measuring charged particle energy distributions from laser fusion targets

  12. Validation of a tracer technique to determine nonsteady-state ketone body turnover rates in man

    International Nuclear Information System (INIS)

    Keller, U.; Sonnenberg, G.E.; Stauffacher, W.

    1981-01-01

    The features of a single-compartment model of total ketone bodies were evaluated using primed constant infusions of [3-14C]acetoacetate (AcAc) and of D-[3-14C]beta-hydroxybutyrate (beta OHB) in 12 postabsorptive subjects. The volume of distribution (VD) of AcAc was 0.18 +- 0.01 liter/kg (n = 9), and that of beta OHB was similar, 0.18 +- 0.02 liter/kg (n = 3). The production rate of total ketone bodies was calculated using the combined specific activity of AcAc and of beta OHB. The mean basal total ketone body production rates were similar using either [14C]AcAc (6.5 mumol . kg-1 . min-1) or [14C]beta OHB (6.8 mumol . kg-1 . min-1). To determine the pool fraction that was rapidly mixed during nonsteady state of ketone body inflow, unlabeled AcAc was infused with stepwise increasing and decreasing rates between 5 and 25 mumol . kg-1 . m-1 to mimic nonsteady-state ketone body production rates. The functional pool fraction P was determined as the pool fraction that provided the best match between tracer-determined rates of ketone production and rates of AcAc infusion. P of total ketone bodies was almost equal to 1 using either [14C]AcAc (1.05 +- 0.16) or [14C]beta OHB (1.00 +- 0.06), suggesting rapid mixing of ketone bodies throughout the entire pool. The described pool model may be used to determine total ketone body kinetics during acute perturbations of the steady state

  13. Structure determination of cyclo pentane terpene derivatives by crossed NMR and MS techniques

    Energy Technology Data Exchange (ETDEWEB)

    Pianet, I.; Bourgeois, G. [Bordeaux-1 Univ., 33 - Talence (France); Dolatkhani, M.; Cramail, H.; Deffieux, A. [Centre National de la Recherche Scientifique (CNRS), 33 - Talence (France)

    1995-10-01

    3 of the 4 stereoisomers of the 1-isopropenyl 2,3-dimethylcyclopentane, obtained from the cracking of 3,7-dimethylocta-1,6-diene, were purified and characterized. Dihedral angles, between the protons of the substituted carbons, have been determined by molecular modelling. Analysis of the NMR and mass spectra allowed us to access to the structure of the different isomers. (authors). 6 refs., 2 tabs.

  14. Determination of uranium in urine samples for workers in the phosphoric acid purification using fluorimetry technique

    International Nuclear Information System (INIS)

    Kharita, M. H.; Sakhita, Kh.; Aldalal, Z.

    2003-10-01

    There is probability of exposure to uranium for workers in the phosphoric acid purification (internal exposure) by inhalation, and the deposition of this uranium in organs and tissues, and the consequence excreation out of the body by perspiration or urine. This study focuses on the determination of uranium in urine samples of workers. All results seem to be under the detection limit of the method, therefore no routine monitoring is required. (author)

  15. An accurate method for determining residual stresses with magnetic non-destructive techniques in welded ferromagnetic steels

    International Nuclear Information System (INIS)

    Vourna, P

    2016-01-01

    The scope of the present research work was to investigate the proper selection criteria for developing a suitable methodology for the accurate determination of residual stresses existing in welded parts. Magnetic non-destructive testing took place by the use of two magnetic non-destructive techniques: by the measurement of the magnetic Barkhausen noise and by the evaluation of the magnetic hysteresis loop parameters. The spatial distribution of residual stresses in welded metal parts by both non-destructive magnetic methods and two diffraction methods was determined. The conduction of magnetic measurements required an initial calibration of ferromagnetic steels. Based on the examined volume of the sample, all methods used were divided into two large categories: the first one was related to the determination of surface residual stress, whereas the second one was related to bulk residual stress determination. The first category included the magnetic Barkhausen noise and the X-ray diffraction measurements, while the second one included the magnetic permeability and the neutron diffraction data. The residual stresses determined by the magnetic techniques were in a good agreement with the diffraction ones. (paper)

  16. Determination of hydrogen content of Jatropha biodiesel oil using neutron reflection technique

    International Nuclear Information System (INIS)

    Okunade, I. O.; Jonah, S. A.; Omede, M.

    2014-01-01

    Biofuel is an environmental-friendly alternative to fossil fuel and holds immense potential for the future energy needs of the country. Non-edible jatropha biodiesel oil has been identified as one of the suitable bio-fuel options. In this work, experimental measurements were performed to determine the total hydrogen content of jatropha oil and jatropha-synthetic diesel oil mixture. The work was carried out using a neutron reflection facility at the Centre for Energy Research and Training, Ahmadu Bello University, Zaria. Jatropha oil and jatropha-synthetic diesel mixture were subjected to experimental measurements for the purpose of determining bulk hydrogen content using neutron reflection facility that had been previously calibrated using various hydrocarbon materials of known hydrogen content. The hydrogen content of the sample were subsequently determined using their measured neutron reflection coefficient values and calibration data. In general, results obtained indicate high hydrogen content range of 10.68-12.16wt% for jatropha oil and the various jatropha-synthetic diesel mixtures. The implication of this is that jatropha oil or jatrophal-synthetic diesel mixture can be used as alternative fuel to mitigate high carbon monoxide emission.

  17. Application of EDRXF technique for the determination of uranium and thorium in beach sand minerals

    International Nuclear Information System (INIS)

    Natarajan, V.

    2013-01-01

    Zircon is a naturally occurring mineral and is available in many locations all over the world, This mineral usually contains U and Th at about 100-500 μg/g. Naturally occurring TiO 2 , containing minerals, rutile and ilmenite have small quantities of associated uranium. Natural rutile may contain upto 10% iron and upto 500 μg/g of uranium. Since the availability of rutile in nature is limited, ilmenite is used as raw material for producing synthetic rutile. In India, from monazite, thorium is separated by Indian Rare Earths Ltd., wherein uranium is a bye product. Since rutile is of importance to the gemstone markets, this is also produced from ilmenite ore. Roasting, reduction and leaching processes are important steps for removal of iron economically and efficiently from ilmenite ore during the production of synthetic rutile. We have developed a method to determine U and Th in zircon, using synthetic powder standards of ZrO 2 , containing U and Th in the range of 50 to 1000 μg/g. The limits of detection for U and Th were determined to be 200 and 100 μg/g respectively. Three zircon ore samples from different locations in India were analyzed for uranium and thorium using the method. The standardized method can be used for fast determination U and Th in zircon samples non-destructively with a precision of 10-20 %. Further another method was developed for the determination of uranium in rutile. Since iron and chromium are among the other impurities co-existing with U in rutile, these analytes have been included in the method. Synthetic standards containing U at 200-10,000 μg/g and Fe, Cr at 100- 2000 μg/g level were prepared and the spectrometer was calibrated using these standards. Two synthetic samples were analyzed using this method to evaluate the method for its reliability and reproducibility. In the present talk, details of these studies will be discussed. Moreover the work carried out on the determination of U/Th in sand minerals by other international

  18. Evaluation of the laser-induced breakdown spectroscopy technique for determination of the chemical composition of copper concentrates

    Science.gov (United States)

    Łazarek, Łukasz; Antończak, Arkadiusz J.; Wójcik, Michał R.; Drzymała, Jan; Abramski, Krzysztof M.

    2014-07-01

    Laser-induced breakdown spectroscopy (LIBS), like many other spectroscopic techniques, is a comparative method. Typically, in qualitative analysis, synthetic certified standard with a well-known elemental composition is used to calibrate the system. Nevertheless, in all laser-induced techniques, such calibration can affect the accuracy through differences in the overall composition of the chosen standard. There are also some intermediate factors, which can cause imprecision in measurements, such as optical absorption, surface structure and thermal conductivity. In this work the calibration performed for the LIBS technique utilizes pellets made directly from the tested materials (old well-characterized samples). This choice produces a considerable improvement in the accuracy of the method. This technique was adopted for the determination of trace elements in industrial copper concentrates, standardized by conventional atomic absorption spectroscopy with a flame atomizer. A series of copper flotation concentrate samples was analyzed for three elements: silver, cobalt and vanadium. We also proposed a method of post-processing the measurement data to minimize matrix effects and permit reliable analysis. It has been shown that the described technique can be used in qualitative and quantitative analyses of complex inorganic materials, such as copper flotation concentrates. It was noted that the final validation of such methodology is limited mainly by the accuracy of the characterization of the standards.

  19. A REVIEW ON THE ANALYTICAL TECHNIQUES USED FOR THE DETERMINATION OF PARACETAMOL IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDS

    Directory of Open Access Journals (Sweden)

    Aisha Noreen

    2016-12-01

    Full Text Available Paracetamol (PM is an active metabolite of phenacetin and belongs to p-aminophenol derivatives. It is also termed as acetaminophen. PM is one of the non-steroidal anti-inflammatory drugs (NSAIDs which is used as an analgesic and antipyretic agent. It is an OTC drug and is used as a common household analgesic. It is not used as a substitute of aspirin or any other NSAIDs. It is a weak cyclooxygenase (COX 1 and 2 inhibitor but may inhibit COX-3 in the central nervous system. Many analytical techniques have been used for the assay of PM in pharmaceutical preparations and biological fluids. These techniques include spectrometry, chromatography, spectrofluorimetry, chemiluminescence, electrochemical techniques, flow injection spectrometry and chronoamperometry. In many pharmaceutical preparations PM is also used in combination with other drugs and these techniques have also been used for their simultaneous determination. A detailed review of various analytical techniques used for the assay of PM has been carried out which would be of great help to the chemists and pharmacists involved in the analysis and quality control of drugs.

  20. Evaluation of the DSC technique in the determination of the terminal temperature solubility of hydrogen in Zircaloy 4

    International Nuclear Information System (INIS)

    Vizcaino, Pablo; Banchik, Abraham D.

    1999-01-01

    The determination of the terminal temperature solubility of hydrogen in the zirconium alloys is a matter of our interest, since the hydride precipitation in these materials make them susceptible to the delay hydrogen cracking (DHC). Nowadays efforts are directed to the determination of this parameter on irradiated materials. In this frame we have begun a program to determine these curves on irradiated zirconium alloys like Zircaloys, Zr 2.5% Nb, Zr 1% Nb, zirconium sponge and high oxygen zirconium with different microstructures using the differential scanning calorimeter technique. The earlier task that we have imposed to us is the evaluation the reproducibility of this technique and the influence of the heating and cooling rates on the results. With these objectives we have initiated this work measuring the terminal temperature solubility (TTS) in unirradiated recrystallized and cold worked Zircaloy-4. We have found that the reproducibility of the technique is good; the average values (TSSD) and (TSSP) agree within the experimental error and the dispersions are low. Variance analysis indicates that the values of TSSD and TSSP do not depend on the heating and cooling rates. Within the rank analyzed the differences in the measurements are only possible to be attributed to statistical and/or experimental errors. The obtained curves of solubility show to a good agreement with the values obtained by others authors until 200 ppm (weight) of hydrogen. Similar comparisons between precipitation curves have not been made in regard to which these values depend on the maximum temperature reached in the experience. (author)

  1. Evaluation of the laser-induced breakdown spectroscopy technique for determination of the chemical composition of copper concentrates

    Energy Technology Data Exchange (ETDEWEB)

    Łazarek, Łukasz, E-mail: lukasz.lazarek@pwr.wroc.pl [Laser and Fiber Electronics Group, Faculty of Electronics, Wroclaw University of Technology, Wyb. Wyspianskiego 27, 50-370 Wroclaw (Poland); Antończak, Arkadiusz J.; Wójcik, Michał R. [Laser and Fiber Electronics Group, Faculty of Electronics, Wroclaw University of Technology, Wyb. Wyspianskiego 27, 50-370 Wroclaw (Poland); Drzymała, Jan [Faculty of Geoengineering, Mining and Geology, Wroclaw University of Technology, Wyb. Wyspianskiego 27, 50-370 Wroclaw (Poland); Abramski, Krzysztof M. [Laser and Fiber Electronics Group, Faculty of Electronics, Wroclaw University of Technology, Wyb. Wyspianskiego 27, 50-370 Wroclaw (Poland)

    2014-07-01

    Laser-induced breakdown spectroscopy (LIBS), like many other spectroscopic techniques, is a comparative method. Typically, in qualitative analysis, synthetic certified standard with a well-known elemental composition is used to calibrate the system. Nevertheless, in all laser-induced techniques, such calibration can affect the accuracy through differences in the overall composition of the chosen standard. There are also some intermediate factors, which can cause imprecision in measurements, such as optical absorption, surface structure and thermal conductivity. In this work the calibration performed for the LIBS technique utilizes pellets made directly from the tested materials (old well-characterized samples). This choice produces a considerable improvement in the accuracy of the method. This technique was adopted for the determination of trace elements in industrial copper concentrates, standardized by conventional atomic absorption spectroscopy with a flame atomizer. A series of copper flotation concentrate samples was analyzed for three elements: silver, cobalt and vanadium. We also proposed a method of post-processing the measurement data to minimize matrix effects and permit reliable analysis. It has been shown that the described technique can be used in qualitative and quantitative analyses of complex inorganic materials, such as copper flotation concentrates. It was noted that the final validation of such methodology is limited mainly by the accuracy of the characterization of the standards. - Highlights: • A laser-induced breakdown spectroscopy technique is introduced for composition monitoring in industrial copper concentrates. • Calibration samples consisted of pellets produced from the tested materials. • The proposed method of post-processing significantly minimizes matrix effects. • The possible uses of this technique are limited mainly by accurate characterization of the standard samples.

  2. Evaluation of the laser-induced breakdown spectroscopy technique for determination of the chemical composition of copper concentrates

    International Nuclear Information System (INIS)

    Łazarek, Łukasz; Antończak, Arkadiusz J.; Wójcik, Michał R.; Drzymała, Jan; Abramski, Krzysztof M.

    2014-01-01

    Laser-induced breakdown spectroscopy (LIBS), like many other spectroscopic techniques, is a comparative method. Typically, in qualitative analysis, synthetic certified standard with a well-known elemental composition is used to calibrate the system. Nevertheless, in all laser-induced techniques, such calibration can affect the accuracy through differences in the overall composition of the chosen standard. There are also some intermediate factors, which can cause imprecision in measurements, such as optical absorption, surface structure and thermal conductivity. In this work the calibration performed for the LIBS technique utilizes pellets made directly from the tested materials (old well-characterized samples). This choice produces a considerable improvement in the accuracy of the method. This technique was adopted for the determination of trace elements in industrial copper concentrates, standardized by conventional atomic absorption spectroscopy with a flame atomizer. A series of copper flotation concentrate samples was analyzed for three elements: silver, cobalt and vanadium. We also proposed a method of post-processing the measurement data to minimize matrix effects and permit reliable analysis. It has been shown that the described technique can be used in qualitative and quantitative analyses of complex inorganic materials, such as copper flotation concentrates. It was noted that the final validation of such methodology is limited mainly by the accuracy of the characterization of the standards. - Highlights: • A laser-induced breakdown spectroscopy technique is introduced for composition monitoring in industrial copper concentrates. • Calibration samples consisted of pellets produced from the tested materials. • The proposed method of post-processing significantly minimizes matrix effects. • The possible uses of this technique are limited mainly by accurate characterization of the standard samples

  3. Deep diving odontocetes foraging strategies and their prey field as determined by acoustic techniques

    Science.gov (United States)

    Giorli, Giacomo

    Deep diving odontocetes, like sperm whales, beaked whales, Risso's dolphins, and pilot whales are known to forage at deep depths in the ocean on squid and fish. These marine mammal species are top predators and for this reason are very important for the ecosystems they live in, since they can affect prey populations and control food web dynamics through top-down effects. The studies presented in this thesis investigate deep diving odontocetes. foraging strategies, and the density and size of their potential prey in the deep ocean using passive and active acoustic techniques. Ecological Acoustic Recorders (EAR) were used to monitor the foraging activity of deep diving odontocetes at three locations around the world: the Josephine Seamount High Sea Marine Protected Area (JHSMPA), the Ligurian Sea, and along the Kona coast of the island of Hawaii. In the JHSMPA, sperm whales. and beaked whales. foraging rates do not differ between night-time and day-time. However, in the Ligurian Sea, sperm whales switch to night-time foraging as the winter approaches, while beaked whales alternate between hunting mainly at night, and both at night and at day. Spatial differences were found in deep diving odontocetes. foraging activity in Hawaii where they forage most in areas with higher chlorophyll concentrations. Pilot whales (and false killer whales, clustered together in the category "blackfishes") and Risso's dolphins forage mainly at night at all locations. These two species adjust their foraging activity with the length of the night. The density and size of animals living in deep sea scattering layers was studied using a DIDSON imaging sonar at multiple stations along the Kona coast of Hawaii. The density of animals was affected by location, depth, month, and the time of day. The size of animals was influenced by station and month. The DIDSON proved to be a successful, non-invasive technique to study density and size of animals in the deep sea. Densities were found to be an

  4. Standardization of the radioimmunoassay technique for the determination of human gastrin and its clinical application

    International Nuclear Information System (INIS)

    Peig Ginabredra, M.G.

    1989-01-01

    It was developed and standardized a system of radioimmunoassay for the determination of gastrin, employing synthetic human gastrin for radioiodination and preparation of standard as well as specific antibody raised rabbits. The hormone was labeled with 125 I by the Cloramine T techique and purified by anion exchange chromatography in QAE-Sephadex A-25, being determined its specific activity. The tracer thus obtained was submitted to analysis of purity by poliacrilamide gel eletrophoresis and precipitation of proteins by trichloroacetic acid. Its stability evaluated according to the time of storage, being its purity and adequation for the use in radioimmunoassay also compared to a tracer obtained from a commercial diagnosis kit. The assays were performed by incubation of radioiodinated gastrin, standard gastrin prepared in plasma free from this hormone (from zero to 500 pmol/l) or samples to be assayed with the antiserum for 4 days at 4 0 C. The separation between the free gastrin and the gastrin bound to the antibody was carried out by adsorption of the free hormone to the charcoal, whose ideal concentration was previously determined. Plasma free from gastrin was obtained from time-expired blood bank plasma submitted to extraction with charcoal. When performed the quality control, this radioimmunoassay was shown specific, accurate, precise and sensitive, allowing the performance of valid assays. Its validation was even confirmed by clear discrimination not only of the gastrin concentration in subjects with very low levels (gastrectomized) and extremely high levels (Zollinger-Ellison syndrome) as well as gastrin concentrations in subjects with other diseases, such as Chagas disease, pernicious anemia and chronic renal failure. (author) [pt

  5. Technique for magnetic susceptibility determination in the highly doped semiconductors by electron spin resonance

    Energy Technology Data Exchange (ETDEWEB)

    Veinger, A. I.; Zabrodskii, A. G.; Tisnek, T. V.; Goloshchapov, S. I.; Semenikhin, P. V. [Ioffe Institute of the Russian Academy of Sciences, St. Petersburg (Russian Federation)

    2014-08-20

    A method for determining the magnetic susceptibility in the highly doped semiconductors is considered. It is suitable for the semiconductors near the metal - insulator transition when the conductivity changes very quickly with the temperature and the resonance line form distorts. A procedure that is based on double integration of the positive part of the derivative of the absorption line having a Dyson shape and takes into account the depth of the skin layer is described. Analysis is made for the example of arsenic-doped germanium samples at a rather high concentration corresponding to the insulator-metal phase transition.

  6. Determination of re-aeration coefficients on high mountain rivers using nuclear techniques

    International Nuclear Information System (INIS)

    Fajardo, Marco

    2001-01-01

    The rivers Machangara and Guayllabamba in Quito, Ecuador, currently are highly polluted, mainly due to human and industrial residues from the city. The objective of this survey is to establish the dynamics of dissolved oxygen in these rivers using the Krypton 85 method to determine the re aeration coefficient in representative sectors of the rivers. In addition, conventional test tracers establish mean flow speed and flow longitudinal dispersion coefficients. The results of this study will be useful for future water quality modelling of these rivers, in order to define their behaviour and auto depurative capacity to treat sludge waters from Quito

  7. Age determination of sediments by Pb-210 using a plastic detector technique

    International Nuclear Information System (INIS)

    Jensen, J.M.; Enge, W.; Erlenkeuser, H.; Willkomm, H.

    1976-01-01

    For age determination of sediments up to 150 years Pb-210 is suitable on grounds of its half life of 22.3 years. By a nitric acid disintegration lead is extracted out ot the sediment and subsequently precipitated electrolytically on Pt-electrodes. The activity of the sample resp. Pb-210 is measured via the alpha-activity of its granddaughter Po-210. As detector a plastic sheet (Cellulose nitrate, CA 80-15, made by Kodak) is used. Investigated was a sediment core from the Kieler Bucht, western Baltic Sea. The results let it appear possible, that the sediment is mixed up by shellfishes (cyprina islandica). (orig.) [de

  8. Age determination of sediments by 210Pb using a plastic detector technique

    International Nuclear Information System (INIS)

    Jensen, J.M.; Enge, W.; Erlenkeuser, H.; Willkomm, A.

    1977-01-01

    For age determination of sediments up to 150y 210 Pb is suitable on grounds of its half-life of 22.3y. By a nitric acid disintegration lead is extracted out of the sediment and subsequently precipitated electrolytically on Pt-electrodes. The activity of the sample resp. 210 Pb is measured via the alpha-activity of its granddaughter 210 Po. As detector a plastic sheet (cellulose nitrate, CA 80-15, made by Kodak) is used. Investigated was a sediment core from the Kieler Bucht, western Baltic Sea. The results make it appear possible, that the sediment is mixed up by shellfish (cyprina islandica). (Auth.)

  9. A volatile tracer-assisted headspace analytical technique for determining the swelling capacity of superabsorbent polymers.

    Science.gov (United States)

    Zhang, Shu-Xin; Jiang, Ran; Chai, Xin-Sheng

    2017-09-01

    This paper reports on a new method for the determination of swelling capacity of superabsorbent polymers by a volatile tracer-assisted headspace gas chromatography (HS-GC). Toluene was used as a tracer and added to the solution for polymers swelling test. Based on the differences of the tracer partitioned between the vapor and hydrogel phase before and after the polymer's swelling capacity, a transition point (corresponding to the material swelling capacity) can be observed when plotting the GC signal of toluene vs. the ratio of solution added to polymers. The present method has good precision (RSDpolymers at the elevated temperatures. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Radiochemical techniques for determining some naturally occurring radionuclides in marine environmental materials

    Energy Technology Data Exchange (ETDEWEB)

    Baker, C W [Ministry of Agriculture, Fisheries and Food, Lowestoft (UK). Fisheries Lab.

    1984-06-15

    The determination of some of the naturally-occurring, alpha-emitting radionuclides in marine environmental materials, is of interest for several reasons. Radium and radon nuclides are potentially useful as oceanographic tracers. Lead and thorium nuclides may be used to study sedimentation rates, mixing processes and bioturbation in sediments. Radium and polonium nuclides are incorporated into food chains and the data may provide a perspective against which to assess the significance, for marine organisms, of exposure to radiation in a marine radioactive waste disposal situation. This paper discusses the manner in which samples are taken, and the radiochemical methods which have been employed to measure the nuclides, together with some data produced.

  11. Gamma-ray attenuation technique for determining density and water content of wood samples

    International Nuclear Information System (INIS)

    Ferraz, E.S.B.; Aguiar, O.

    1985-01-01

    The theoretical aspects of application of the Beer-Lambert law are discussed, with emphasis on the maximum theoretical error expected. A serie of measurements of moisture content within the range of 8g/cm 3 to 30g/cm 3 are made on samples of Pinus oocarpa by gamma-ray ( 241 Am) attenuation methods and by the conventional gravimetric method. The relative deviations (experimental errors) found in the determinations made by these two methods are compared with the theoretical errors calculated, showing the viability of the gamma-ray method. (M.A.C.) [pt

  12. Recent Analytical Techniques Advances in the Carotenoids and Their Derivatives Determination in Various Matrixes.

    Science.gov (United States)

    Giuffrida, Daniele; Donato, Paola; Dugo, Paola; Mondello, Luigi

    2018-04-04

    In the present perspective, different approaches to the carotenoids analysis will be discussed providing a brief overview of the most advanced both monodimensional and bidimensional liquid chromatographic methodologies applied to the carotenoids analysis, followed by a discussion on the recents advanced supercritical fluid chromatography × liquid chromatography bidimensional approach with photodiode-array and mass spectrometry detection. Moreover a discussion on the online supercritical fluid extraction-supercritical fluid chromatography with tandem mass spectrometry detection applied to the determination of carotenoids and apocarotenoids will also be provided.

  13. Comparison of metaheuristic techniques to determine optimal placement of biomass power plants

    International Nuclear Information System (INIS)

    Reche-Lopez, P.; Ruiz-Reyes, N.; Garcia Galan, S.; Jurado, F.

    2009-01-01

    This paper deals with the application and comparison of several metaheuristic techniques to optimize the placement and supply area of biomass-fueled power plants. Both, trajectory and population-based methods are applied for our goal. In particular, two well-known trajectory method, such as Simulated Annealing (SA) and Tabu Search (TS), and two commonly used population-based methods, such as Genetic Algorithms (GA) and Particle Swarm Optimization (PSO) are hereby considered. In addition, a new binary PSO algorithm has been proposed, which incorporates an inertia weight factor, like the classical continuous approach. The fitness function for the metaheuristics is the profitability index, defined as the ratio between the net present value and the initial investment. In this work, forest residues are considered as biomass source, and the problem constraints are: the generation system must be located inside the supply area, and its maximum electric power is 5 MW. The comparative results obtained by all considered metaheuristics are discussed. Random walk has also been assessed for the problem we deal with.

  14. Determination of origin and intended use of plutonium metal using nuclear forensic techniques.

    Science.gov (United States)

    Rim, Jung H; Kuhn, Kevin J; Tandon, Lav; Xu, Ning; Porterfield, Donivan R; Worley, Christopher G; Thomas, Mariam R; Spencer, Khalil J; Stanley, Floyd E; Lujan, Elmer J; Garduno, Katherine; Trellue, Holly R

    2017-04-01

    Nuclear forensics techniques, including micro-XRF, gamma spectrometry, trace elemental analysis and isotopic/chronometric characterization were used to interrogate two, potentially related plutonium metal foils. These samples were submitted for analysis with only limited production information, and a comprehensive suite of forensic analyses were performed. Resulting analytical data was paired with available reactor model and historical information to provide insight into the materials' properties, origins, and likely intended uses. Both were super-grade plutonium, containing less than 3% 240 Pu, and age-dating suggested that most recent chemical purification occurred in 1948 and 1955 for the respective metals. Additional consideration of reactor modeling feedback and trace elemental observables indicate plausible U.S. reactor origin associated with the Hanford site production efforts. Based on this investigation, the most likely intended use for these plutonium foils was 239 Pu fission foil targets for physics experiments, such as cross-section measurements, etc. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. [Sizes of bacterial cells in soils determined by cascade filtration technique].

    Science.gov (United States)

    Polianskaia, L M; Gorodnichev, R B; Zviagintsev, D G

    2013-01-01

    This paper studies the number of bacteria in typical chernozem and mountain-meadow soil by the traditional method and the cascade filtration technique. The total number of bacteria in these soils, which was obtained in filters of different diameters during filtering the suspension of a certain amount, is 1.5-5 times higher than that obtained by the traditional method. In the structure of the bacterial biomass in both soils, the biomass of bacterial cells with a diameter of 0.38-0.43 microm was dominating by 8-90%. In the typical chernozem, the biomass of cells with a diameter of 0.17 microm was slightly more than 1%; in the mountain-meadow soil, the percentage of the biomass of cells with a diameter of 0.17 microm increased by 5%. The average volume and diameter of the bacteria in the studied soils were calculated. In typical chernozem, the average volume of bacterial cells was equal to 0.0046 microm3 and the diameter was 0.206 microm. In the mountain-meadow soils, these values were slightly lower, 0.0038 microm3 and 0.194 microm, respectively. The biomass of the bacterial cells, which is usually calculated based on the cell volume of 0.1 microm3, is overestimated by about five times when counting the number on the filters. The percentage of the real biomass of soil bacteria is traditionally much lower than that estimated.

  16. Comparison of metaheuristic techniques to determine optimal placement of biomass power plants

    Energy Technology Data Exchange (ETDEWEB)

    Reche-Lopez, P.; Ruiz-Reyes, N.; Garcia Galan, S. [Telecommunication Engineering Department, University of Jaen Polytechnic School, C/ Alfonso X el Sabio 28, 23700 Linares, Jaen (Spain); Jurado, F. [Electrical Engineering Department, University of Jaen Polytechnic School, C/ Alfonso X el Sabio 28, 23700 Linares, Jaen (Spain)

    2009-08-15

    This paper deals with the application and comparison of several metaheuristic techniques to optimize the placement and supply area of biomass-fueled power plants. Both, trajectory and population-based methods are applied for our goal. In particular, two well-known trajectory method, such as Simulated Annealing (SA) and Tabu Search (TS), and two commonly used population-based methods, such as Genetic Algorithms (GA) and Particle Swarm Optimization (PSO) are hereby considered. In addition, a new binary PSO algorithm has been proposed, which incorporates an inertia weight factor, like the classical continuous approach. The fitness function for the metaheuristics is the profitability index, defined as the ratio between the net present value and the initial investment. In this work, forest residues are considered as biomass source, and the problem constraints are: the generation system must be located inside the supply area, and its maximum electric power is 5 MW. The comparative results obtained by all considered metaheuristics are discussed. Random walk has also been assessed for the problem we deal with. (author)

  17. Comparative study of modern extraction techniques for the determination of environmental samples (M14)

    International Nuclear Information System (INIS)

    Gfrerer, M.; Lankmayr, E.

    2002-01-01

    Full text: The aim of any extraction method in analytical chemistry is, to effectively separate the analytes from the matrix. The whole step should be fast and quantitative with minimal solvent and time required. The classical Soxhlet extraction usually requires large volumes (up to 200 ml) of solvent to be refluxed through the solid samples for several hours. Therefore, in the last decades, alternatives for this extraction method have been presented and investigated such as ultrasonic extraction (UE), supercritical fluid extraction (SFE), accelerated solvent extraction (ASE), microwave-assisted extraction (MAE) and fluidized-bed extraction (FBE). The actual choice for analytical application is frequently the initial capital cost, operating costs, simplicity of operation, amount of organic solvent required and sample throughput. Since sample preparation is a critical step in the analytical cycle, special care has to be taken for an accurate choice and optimization of extraction techniques and clean-up procedures. Therefore, MAE and FBE were investigated for their influential extraction parameters and these parameters were optimized for the extraction of organochlorine biocides, polychlorinated biphenyls and polycyclic aromatic hydrocarbons from environmental matrices like soil, sediment and sewage sludge. The extraction yields were compared with those obtained by Soxhlet extraction performed following DIN-methods. Finally, the optimized modern methods were validated by systematic experiments with certified reference materials. Refs. 3 (author)

  18. Normal emission photoelectron diffraction: a new technique for determining surface structure

    International Nuclear Information System (INIS)

    Kevan, S.D.

    1980-05-01

    One technique, photoelectron diffraction (PhD) is characterized. It has some promise in surmounting some of the problems of LEED. In PhD, the differential (angle-resolved) photoemission cross-section of a core level localized on an adsorbate atom is measured as a function of some final state parameter. The photoemission final state consists of two components, one of which propagates directly to the detector and another which scatters off the surface and then propagates to the detector. These are added coherently, and interference between the two manifests itself as cross-section oscillations which are sensitive to the local structure around the absorbing atom. We have shown that PhD deals effectively with two- and probably also three-dimensionally disordered systems. Its non-damaging and localized, atom-specific nature gives PhD a good deal of promise in dealing with molecular overlayer systems. It is concluded that while PhD will never replace LEED, it may provide useful, complementary and possibly also more accurate surface structural information

  19. Soil erosion determinations using 137Cs technique in the agricultural regions of Gediz Basin, Western Turkey

    International Nuclear Information System (INIS)

    Sac, M.; Ymurtaci, E.; Yener, G.; Ugur, A.; Ozden, B.; Camgoz, B.

    2004-01-01

    Gediz basin is one of the regions where intense agricultural activities take place in Western Turkey. Erosion and soil degradation has long been causing serious problems to cultivated fields in the basin. This work describes the application of two different 137 Cs models for estimating soil erosion rates in cultivated sites of the region. Soil samples were collected from five distinct cultivated regions subject to soil erosion. The variations of 137 Cs concentrations with depth in soil profiles were investigated. Soil loss rates were calculated from 137 Cs inventories of the samples using both Proportional Model (PM) and Simplified Mass Balance Model (SMBM). When Proportional Model was used, erosion and deposition rates varied from -15 to -28 t ha -1 y -1 and from +5 to +41 t ha ha -1 y -1 , respectively, they varied from -16 to -33 t ha -1 y -1 and from +5 to +55 t ha -1 y -1 with Simplified Mass Balance Model. A good agreement was observed between the results of two models up to 30 t ha -1 y -1 soil loss and gain in the study area. Ulukent, a small representative agricultural field, was selected to compare the present data of 137 Cs techniques with the results obtained by Universal Soil Loss Equation (USLE) applied in the area before. (authors)

  20. CANDU fuel sheath integrity and oxide layer thickness determination by Eddy current technique

    International Nuclear Information System (INIS)

    Gheorghe, Gabriela; Man, Ion; Parvan, Marcel; Valeca, Serban

    2010-01-01

    This paper presents results concerning the integrity assessment of the fuel elements cladding and measurements of the oxide layer on sheaths, using the eddy current technique. Flaw detection using eddy current provides information about the integrity of fuel element sheath or presence of defects in the sheath produced by irradiation. The control equipment consists of a flaw detector with eddy currents, operable in the frequency range 10 Hz to 10 MHz, and a differential probe. The calibration of the flaw detector is done using artificial defects (longitudinal, transversal, external and internal notches, bored and unbored holes) obtained on Zircaloy-4 tubes identical to those out of which the sheath of the CANDU fuel element is manufactured (having a diameter of 13.08 mm and a wall thickness of 0.4 mm). When analyzing the behavior of the fuel elements' cladding facing the corrosion is important to know the thickness of the zirconium oxide layer. The calibration of the device measuring the thickness of the oxide layer is done using a Zircaloy-4 tube identical to that which the cladding of the CANDU fuel element is manufactured of, and calibration foils, as well. (authors)

  1. The optimation of radon-222 determination in water by Lucas cell technique

    International Nuclear Information System (INIS)

    Andrejkovicova, S.; Kuruc, J.; Kovacsova, A.; Mackova, J.; Rajec, P.

    2003-01-01

    The aim of this work was to determine detection efficiency ε, volume activity a v , low detection limit, minimal detection activity for radon. There were collecting several samples of water: water from tap water, mineral water, thermal water, water from wells and bottled drinking water. As we expected, the lowest values of volume activities of radon were reached in bottled drinking water (0.1 - 4.9 Bq/dm 3 ). Higher values were reached in water from tap water and natural mineral water (2.5 - 14.9 Bq/dm 3 ). The highest volume activities of radon were obtained in thermal water and water from wells (17.2 - 107.9 Bq/dm 3 ). Method for determination of radon in water was verified at Institute of Preventive and Clinical Medicine, Bratislava, Slovakia. Results of radon concentration in waters are in accordance with an uppermost - accepted value of radon in water. The volume activity of radon in our samples has never been higher as a limit value has allowed (300 Bq/dm 3 ). (authors)

  2. A miniaturized technique for assessing protein thermodynamics and function using fast determination of quantitative cysteine reactivity.

    Science.gov (United States)

    Isom, Daniel G; Marguet, Philippe R; Oas, Terrence G; Hellinga, Homme W

    2011-04-01

    Protein thermodynamic stability is a fundamental physical characteristic that determines biological function. Furthermore, alteration of thermodynamic stability by macromolecular interactions or biochemical modifications is a powerful tool for assessing the relationship between protein structure, stability, and biological function. High-throughput approaches for quantifying protein stability are beginning to emerge that enable thermodynamic measurements on small amounts of material, in short periods of time, and using readily accessible instrumentation. Here we present such a method, fast quantitative cysteine reactivity, which exploits the linkage between protein stability, sidechain protection by protein structure, and structural dynamics to characterize the thermodynamic and kinetic properties of proteins. In this approach, the reaction of a protected cysteine and thiol-reactive fluorogenic indicator is monitored over a gradient of temperatures after a short incubation time. These labeling data can be used to determine the midpoint of thermal unfolding, measure the temperature dependence of protein stability, quantify ligand-binding affinity, and, under certain conditions, estimate folding rate constants. Here, we demonstrate the fQCR method by characterizing these thermodynamic and kinetic properties for variants of Staphylococcal nuclease and E. coli ribose-binding protein engineered to contain single, protected cysteines. These straightforward, information-rich experiments are likely to find applications in protein engineering and functional genomics. Copyright © 2010 Wiley-Liss, Inc.

  3. Comparison of different thin layer detection techniques to determine the radiochemical purity of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Hammermaier, A.; Reich, E.; Boegl, W.

    1985-01-01

    Ten radiopharmaceuticals frequently used in clinical treatment were examined as to their radiochemical purity by paper and thin layer chromatography or electrophoresis, respectively. It is known that radiochemical impurities may result in an unnecessary exposure of the patients to be examined. Other than determining the radiochemical purity of several radiopharmaceuticals, a comparison of the different measuring methods of distributing activity on radiochromatograms or electropherograms is intended by this study. For this, the activity distribution in the developed radiochromatograms was assessed by four different measuring methods (TLC-linear analyzer, TLC-scanner with NaI(Tl) detector, TLC-scanner with gas flow counter and NaI(Tl) well-typ counter). As shown by the above analysis, only the TLC-linear analyzer and the NaI(Tl) well-typ counter (measurement of chromatograms or electropherograms cut into strips) are generally suitable methods for determining the radiochemical purity of radiochemicals, the TLC-scanner with gas flow counter is usable in most cases, while TLC-scanner with NaI(Tl) detector is yielding unsatisfactory results. (orig.) [de

  4. Determination of elemental composition of some aphrodisiac herbs by Nuclear Analytical Technique (INAA)

    International Nuclear Information System (INIS)

    Mohammed, L.; Okunade, I.O.; Balogun, G.I.

    2011-01-01

    Fresh medicinal plants that are popularly believed to have aphrodisiac properties were collected in the form of leaves, stem bark, nuts, fruits, seeds, and roots, between 25th September 2009 and 15 October 2009. Instrumental Neutron Activation Analysis (INAA) has been applied to multielemental determination of thirteen aphrodisiac herbs used to treat the problem of Sexual dysfunction. Concentrations of twenty two elements AI, As, Ba, Br, Ca, Co, Cr, Cs, Dy, Eu, Fe, Hf, K, La, Lu, Mg, Mn, Na, Rb, Sb, Sc, Sm, Ta, Th, Ti, U, V, Yb, and Zn have been determined by short and long irradiation times with a thermal neutron flux of 5* 1011ncm-2s-1. Quality control and quality assurance of the method was tested by analyzing IAEA-359 and SRM-1573 together with the samples. The INAA spectra were analyzed using WINSPAN 2004 software package. Our result shows that Euphobia hirta recorded high Zn (669±34 g g-1) which is more than the amount (95.0 g g-1) in Jaipal sex tonic. The level of Fe in Cassytha filiformis, and Indigofera hirsute, is 599 g g-1 and 702 g g-1 respectively. These values are in good agreement with the Fe concentration in the popular aphrodisiac Panax gingseng and Radix codonopsis. For all the species of the same family the correlation coefficients are highly distinctive for each species. The present study can be use to some extent to assess the safety intake of aphrodisiac herbs in the final formulation.

  5. Application of the PROMETHEE technique to determine depression outlet location and flow direction in DEM

    Science.gov (United States)

    Chou, Tien-Yin; Lin, Wen-Tzu; Lin, Chao-Yuan; Chou, Wen-Chieh; Huang, Pi-Hui

    2004-02-01

    With the fast growing progress of computer technologies, spatial information on watersheds such as flow direction, watershed boundaries and the drainage network can be automatically calculated or extracted from a digital elevation model (DEM). The stubborn problem that depressions exist in DEMs has been frequently encountered while extracting the spatial information of terrain. Several filling-up methods have been proposed for solving depressions. However, their suitability for large-scale flat areas is inadequate. This study proposes a depression watershed method coupled with the Preference Ranking Organization METHod for Enrichment Evaluations (PROMETHEEs) theory to determine the optimal outlet and calculate the flow direction in depressions. Three processing procedures are used to derive the depressionless flow direction: (1) calculating the incipient flow direction; (2) establishing the depression watershed by tracing the upstream drainage area and determining the depression outlet using PROMETHEE theory; (3) calculating the depressionless flow direction. The developed method was used to delineate the Shihmen Reservoir watershed located in Northern Taiwan. The results show that the depression watershed method can effectively solve the shortcomings such as depression outlet differentiating and looped flow direction between depressions. The suitability of the proposed approach was verified.

  6. Fluorine determination in human healthy and carious teeth using the PIGE technique

    International Nuclear Information System (INIS)

    Carvalho, M.L.; Karydas, A.G.; Casaca, C.; Zarkadas, Ch.; Paradellis, Th.; Kokkoris, M.; Nsouli, B.; Cunha, A.S.

    2001-01-01

    The purpose of this study is to determine and compare the fluorine concentration in human teeth from two different populations, living in the Portuguese quite isolated islands of Acores: S. Miguel and Terceira. Both populations have similar dietary habits, similar occupational activities, mostly rural, and the age of both populations is more or less the same, around 40 years. No chronic diseases were registered in any of the donors. The two groups are exposed to different levels of fluorine in drinking water. Terceira island has moderate fluorine concentration levels (1-2 μg g -1 ) while S. Miguel island is known for the high fluorine concentration levels in its water (>3 μg g -1 ), especially in one area known as Furnas. Thirty-three teeth, 17 healthy and 16 carious without restoration (14 incisors and canines, 7 premolars and 12 molars), were collected and analyzed for the determination of fluorine concentration in the dentine region, using the nuclear reaction 19 F(p,αγ) 16 O. The teeth were cross-sectioned along the vertical plane and polished, in order to obtain a smooth and plane surface of about 1 mm thickness. In this work an association between caries prevalence and fluorine content of drinking water is discussed and the variation of fluorine concentration among different types of teeth (canines and incisors, premolars, molars) and physical state (carious and non-carious) is examined

  7. Determination of traffic intensity from camera images using image processing and pattern recognition techniques

    Science.gov (United States)

    Mehrübeoğlu, Mehrübe; McLauchlan, Lifford

    2006-02-01

    The goal of this project was to detect the intensity of traffic on a road at different times of the day during daytime. Although the work presented utilized images from a section of a highway, the results of this project are intended for making decisions on the type of intervention necessary on any given road at different times for traffic control, such as installation of traffic signals, duration of red, green and yellow lights at intersections, and assignment of traffic control officers near school zones or other relevant locations. In this project, directional patterns are used to detect and count the number of cars in traffic images over a fixed area of the road to determine local traffic intensity. Directional patterns are chosen because they are simple and common to almost all moving vehicles. Perspective vision effects specific to each camera orientation has to be considered, as they affect the size and direction of patterns to be recognized. In this work, a simple and fast algorithm has been developed based on horizontal directional pattern matching and perspective vision adjustment. The results of the algorithm under various conditions are presented and compared in this paper. Using the developed algorithm, the traffic intensity can accurately be determined on clear days with average sized cars. The accuracy is reduced on rainy days when the camera lens contains raindrops, when there are very long vehicles, such as trucks or tankers, in the view, and when there is very low light around dusk or dawn.

  8. Application of HPLC-DAD Technique for Determination of Phenolic Compounds in Bee Pollen Loads

    Directory of Open Access Journals (Sweden)

    Waś Ewa

    2017-06-01

    Full Text Available A method was elaborated to determine phenolic compounds (vanillin, caffeic, p-coumaric and salicylic acids, and flavonoids: rutin, hesperetin, quercetin, pinocembrin, apigenin, kaempferol, isorhamnetin, chrysin, and acacetin in bee pollen loads using highperformance liquid chromatography with a diode array detector (HPLC-DAD. Phenolic compounds from bee pollen were isolated on Cleanert C18-SPE columns (500 mg/6 mL, Agela Technologies. Polyphenols were identified by comparing the retention times and spectra of compounds found in pollen load samples with the ones of the standard mixture. Quantitative analysis was conducted using the external standard method. In addition, basic validation parameters for the method were determined. For the identified compounds (except for the salicylic acid, satisfactory (≥0.997 linear correlations were obtained. The elaborated method showed high repeatability and inter-laboratory reproducibility. Variability coeffcients of the majority of phenolic compounds did not exceed 10% in conditions of repeatability and inter-laboratory reproducibility, and for the total polyphenolic content they were 1.7 and 5.1%, respectively. The pollen load samples (n = 15 differed in qualitative and quantitative composition of the phenolic compounds. In all the samples, we identified the p-coumaric and salicylic acids and flavonoids rutin, hesperetin, and apigenin nevertheless, these compounds’ contents significantly differed among individual samples. The total phenolic content in the tested samples of pollen loads ranged from 0.653 to 5.966 mg/100 g (on average 2.737 mg/100 g.

  9. The use of radiometric-logging techniques to determine uranium grade in certain mineralised Karoo boreholes

    International Nuclear Information System (INIS)

    Corner, B.; De Beer, G.P.

    1976-05-01

    During the period September-October 1975, 22 mineralised boreholes in nine different Karoo uranium occurrences were logged radiometrically with the aim of determining to what accuracy the actual uranium grade could be predicted from the gamma logs. The true uranium grades of the mineralised zones logged were known from existing chemical analyses. The results showed that the uranium grades could be predicted to an accuracy of better than 10% through the use of gamma-logging equipment calibrated at Pelindaba, provided that the ore was in equilibrium and that little or no thorium was present. Disequilibrium is, however, prevalent in the Karoo, and in the holes logged it occurred by depletion of uranium relative to its gamma-emitting daughter products. Such effects were mostly confined to the zone above the water table, and it is concluded that for Karoo-type occurrences, the high radiometric background levels observed over extended distances in some boreholes were indicative of radon-gas buildup, and hence of disequilibrium. It is further concluded that radiometric borehole logging can largely replace chemical analyses in the determination of uranium grade for ore-reserve calculations, although chemical checks for disequilibrium would always be necessary [af

  10. Metabolite-balancing techniques vs. 13C tracer experiments to determine metabolic fluxes in hybridoma cells.

    Science.gov (United States)

    Bonarius, H P; Timmerarends, B; de Gooijer, C D; Tramper, J

    The estimation of intracellular fluxes of mammalian cells using only mass balances of the relevant metabolites is not possible because the set of linear equations defined by these mass balances is underdetermined. In order to quantify fluxes in cyclic pathways the mass balance equations can be complemented with several constraints: (1) the mass balances of co-metabolites, such as ATP or NAD(P)H, (2) linear objective functions, (3) flux data obtained by isotopic-tracer experiments. Here, these three methods are compared for the analysis of fluxes in the primary metabolism of continuously cultured hybridoma cells. The significance of different theoretical constraints and different objective functions is discussed after comparing their resulting flux distributions to the fluxes determined using 13CO2 and 13C-lactate measurements of 1 - 13C-glucose-fed hybridoma cells. Metabolic fluxes estimated using the objective functions "maximize ATP" and "maximize NADH" are relatively similar to the experimentally determined fluxes. This is consistent with the observation that cancer cells, such as hybridomas, are metabolically hyperactive, and produce ATP and NADH regardless of the need for these cofactors. Copyright 1998 John Wiley & Sons, Inc.

  11. Pb, U, Ti, Hf and Zr distributions in zircons determined by proton microprobe and fission track techniques

    International Nuclear Information System (INIS)

    Clark, G.J.; Gulson, B.L.; Cookson, J.A.

    1979-01-01

    A proton microprobe has been used to determine Pb, Tl, Hf and Zr distributions across four single zircon crystals separated from a 'rapakivi' granite. The Pb and Zr data are quantitative: Pb and Tl concentrations were below the measurable limits for determinations in situ by most other techniques. The distribution of U in the same crystals was determined by the fission track technique. Limits on precision of U allow only a qualitative correlation of U and Pb, whereas the Tl and Pb correlation is more exactly determined. Zircons with distinct cores and overgrowths exhibited uniform Zr and Hf concentrations across the crystals, whereas the high U rims and 'inclusions' (domains) also had high Tl and Pb contents. Since almost all the Pb in these zircons is derived by radioactive decay of U, the Tl substitution has paralleled that of U. The results indicate that the high U domains are 'hot spots' rather than a separate mineral phase. The strong positive correlation of U and Pb indicates that there is little U daughter product migration relative to U, within the crystal. However, for the zircon population investigated here, the data are equivocal on the question of whether U addition to zircon crystals is associated with new zircon growth or not. In either case, the heterogeneous U and Pb distributions complicate any interpretations of U-Pb isotopic analysis for such zircon populations. (author)

  12. Experimental determination of nuclear reaction rates (n,γ) by the gamma-rays capture spectrometry technique

    International Nuclear Information System (INIS)

    Lucatero, M.A.

    1976-01-01

    The technique of the gamma-rays capture spectrometry was used in the experimental determination of nuclear reaction rates of the type (n,γ). This technique consists in the incidence of a thermal neutrons collimated beam upon a sample, detecting the capture spectrum of gamma rays emitted at a solid fixed angle. In the determination of the efficiency curve intrinsic to the detection electronic system the reactions 199 Hg(n,γ) 200 Hg, 56 Fe(n,γ) 57 Fe and 63 Cu(n,γ) 64 Cu were used with the energy of the gamma rays capture of 5.976, 7.635 and 7.915 Mev respectively, through the irradiation of standard samples of Hg(175.3g), Fe(110.4g) and Cu(108.5g) of cylindrical geometry the two former and parallelepiped the latter. The problem concerning the corrections due to the thermal neutrons flux depression, the gammas auto-attenuation, and the geometric factor due to the cylindrical and parallelepiped geometry are involved in the data process. The experimental determination of the reaction 35 Cl(n,γ) 36 Cl rate was made through the observation of the gamma caputre of 6.111 Mev when a sample of CaCl 2 of cylindrical geometry was irradiated. This rate can be favorably compared with the reaction rate determined theoretically. (author)

  13. Determining the stereochemical structures of molecular ions by ''Coulomb-explosion'' techniques with fast (MeV) molecular ion beams

    International Nuclear Information System (INIS)

    Gemmell, D.S.

    1980-01-01

    Recent studies on the dissociation of fast (MeV) molecular ion beams in thin foils suggest a novel alternative approach to the determination of molecular ion structures. In this article we review some recent high-resolution studies on the interactions of fast molecular ion beams with solid and gaseous targets and indicate how such studies may be applied to the problem of determining molecular ion structures. The main features of the Coulomb explosion of fast-moving molecular ion projectiles and the manner in which Coulomb-explosion techniques may be applied to the problem (difficult to attack by more conventional means) of determining the stereochemical structures of molecular ions has been described in this paper. Examples have been given of early experiments designed to elicit structure information. The techniques are still in their infancy, and it is to be expected that as both the technology and the analysis are refined, the method will make valuable contributions to the determination of molecular ion structures

  14. Determination of the ecological connectivity between landscape patches obtained using the knowledge engineer (expert) classification technique

    Science.gov (United States)

    Selim, Serdar; Sonmez, Namik Kemal; Onur, Isin; Coslu, Mesut

    2017-10-01

    Connection of similar landscape patches with ecological corridors supports habitat quality of these patches, increases urban ecological quality, and constitutes an important living and expansion area for wild life. Furthermore, habitat connectivity provided by urban green areas is supporting biodiversity in urban areas. In this study, possible ecological connections between landscape patches, which were achieved by using Expert classification technique and modeled with probabilistic connection index. Firstly, the reflection responses of plants to various bands are used as data in hypotheses. One of the important features of this method is being able to use more than one image at the same time in the formation of the hypothesis. For this reason, before starting the application of the Expert classification, the base images are prepared. In addition to the main image, the hypothesis conditions were also created for each class with the NDVI image which is commonly used in the vegetation researches. Besides, the results of the previously conducted supervised classification were taken into account. We applied this classification method by using the raster imagery with user-defined variables. Hereupon, to provide ecological connections of the tree cover which was achieved from the classification, we used Probabilistic Connection (PC) index. The probabilistic connection model which is used for landscape planning and conservation studies via detecting and prioritization critical areas for ecological connection characterizes the possibility of direct connection between habitats. As a result we obtained over % 90 total accuracy in accuracy assessment analysis. We provided ecological connections with PC index and we created inter-connected green spaces system. Thus, we offered and implicated green infrastructure system model takes place in the agenda of recent years.

  15. Comparison of segmentation techniques to determine the geometric parameters of structured surfaces

    International Nuclear Information System (INIS)

    MacAulay, Gavin D; Giusca, Claudiu L; Leach, Richard K; Senin, Nicola

    2014-01-01

    Structured surfaces, defined as surfaces characterized by topography features whose shape is defined by design specifications, are increasingly being used in industry for a variety of applications, including improving the tribological properties of surfaces. However, characterization of such surfaces still remains an issue. Techniques have been recently proposed, based on identifying and extracting the relevant features from a structured surface so they can be verified individually, using methods derived from those commonly applied to standard-sized parts. Such emerging approaches show promise but are generally complex and characterized by multiple data processing steps making performance difficult to assess. This paper focuses on the segmentation step, i.e. partitioning the topography so that the relevant features can be separated from the background. Segmentation is key for defining the geometric boundaries of the individual feature, which in turn affects any computation of feature size, shape and localization. This paper investigates the effect of varying the segmentation algorithm and its controlling parameters by considering a test case: a structured surface for bearing applications, the relevant features being micro-dimples designed for friction reduction. In particular, the mechanisms through which segmentation leads to identification of the dimple boundary and influences dimensional properties, such as dimple diameter and depth, are illustrated. It is shown that, by using different methods and control parameters, a significant range of measurement results can be achieved, which may not necessarily agree. Indications on how to investigate the influence of each specific choice are given; in particular, stability of the algorithms with respect to control parameters is analyzed as a means to investigate ease of calibration and flexibility to adapt to specific, application-dependent characterization requirements. (paper)

  16. Determination of pesticides in fruits and vegetables using acetonitrile extraction and GC/MS technique

    International Nuclear Information System (INIS)

    Hussain, Z.

    2010-01-01

    A selection of oranges, guava and spinach were purchased from the local markets of Lahore, Pakistan. Extraction of the samples was carried out using an acetonitrile/toluene extraction procedure to determine the residual concentration of pesticides which may have been used during seasonal growth. Gas chromatography/mass spectrometry (GC/MS) was used for quantitative and confirmatory analysis of GC-amenable pesticides. The data obtained was compared with that of a referenced pesticide by matching molecular weight to a library of known pesticides. For comparison the same non-sprayed fruits/vegetable were extracted as a control reference. Factors studied were retention time, elution time, relative abundance and molecular weight. The results showed that low molecular weight pesticides were eluted before the high molecular weight pesticides. Pesticides identified included crotoxyphos, fenoxycarb and methoxyfenozide. (author)

  17. Determination of the phthalocyanine textile dye, reactive turquoise blue, by electrochemical techniques

    Directory of Open Access Journals (Sweden)

    Osugi Marly E.

    2003-01-01

    Full Text Available Turquoise blue 15 (AT15 is a reactive dye widely used in the textile industry to color natural fibers. The presence of these dyes in effluent and industrial wastewater is of considerable interest due ecotoxicological and environmental problems. The electrochemical reduction of this dye has been investigated in aqueous solution using cyclic voltammetry, controlled potential electrolysis and cathodic stripping voltammetry. Optimum conditions for dye discoloration by controlled potential electrolysis use an alkaline medium. Using cathodic stripping voltammetry a linear calibration graph was obtained from 5.00x10-8 mol L-1 to 1.00x10-6 mol L-1 of AT15 at pH 4.0, using accumulation times of 180 and 240 s and an accumulation potential of 0.0 V. The proposed method was applied in direct determination of the dye in tap water and in textile industry effluent.

  18. Determination of the system function for the particle circulation process using perturbation technique in QUEST

    International Nuclear Information System (INIS)

    Zushi, H.; Kuzmin, A.; Hasegawa, M.; Yoshida, N.; Fujisawa, A.; Hanada, K.; Idei, H.; Nakamura, K.; Nagashima, Y.; Onchi, T.; Takagi, I.; Fukuyama, A.; Sharma, S.K.; Kobayashi, M.; Hirooka, Y.; Zhou, H.; Matsuoka, K.; Kubo, S.; Rusinov, A.; Inoue, A.; Tashima, S.; Banerjee, S.; Sakaguchi, M.; Kalinnikova, E.; Mishra, K.; Liu, X.; Ueda, Y.; Fujita, T.; Ohno, N.; Ide, Shunsuke; Hatayama, A.; Ejiri, A.; Yamaguchi, T.; Hiratsuka, J.; Togashi, H.; Takase, Y.; Mitarai, O.

    2014-10-01

    The global gas balance in the various types of steady discharges has been re-examined by measuring the partial pressures of hydrogen and helium, and plasma induced permeated flux at various positions. A new approach to study the dynamics of particle circulation in steady state tokamak operation SSTO has been proposed and demonstrated in QUEST with all metal walls baked at 100°C. Using perturbations of particle source H 2 and plasma-wall interaction PWI the system functions of processes of retention and release into/from the wall are determined both in time and frequency domains. The time dependent probability function of the transition between high and low recycling states has been derived. (author)

  19. DETERMINATION OF OPERATOR’S IMPACT ON THE MEASUREMENT DONE USING COORDINATE TECHNIQUE

    Directory of Open Access Journals (Sweden)

    Ksenia Ostrowska

    2013-12-01

    Full Text Available Coordinate measuring arms (CMAs are devices which more and more often replace conventional coordinate measuring machines because of their undoubted advantages, such as mobility, the opportunity to increase the measuring volume, the opportunity to connect the optical probe, and above all, good price-quality ratio. Because these devices are handheld and redundant, what has the greatest impact on the measurement result accuracy are the operator, the machine kinematics and its ability to obtain repeatable measurement results; despite the fact that one point can be obtained from an infinite number of shoulders’ positions. In this paper it was determined by using R&R method how significant are the impacts of both the operator and the measuring device on the accuracy of measurements done with CMA, both with rigid switch probe and optical probe.

  20. modern techniques and new sensors for determination of some metal ions

    International Nuclear Information System (INIS)

    Aglan, R.F.E.S.

    2004-01-01

    this work has been carried out to prepare some new sensors that can be used i the radioactive media. A novel homogenous solid state sensor responding to potassium ion was developed. i revealed good linear response with slope 44 ± 0.5 mV/decade over he concentration range 10 -4 -1.0 mol 1 -1 potassium ion with long life, high thermal and radiation stability. the influence of plasticizer, ionophore and conducting substrate on the analytical characterization of uranyl ion selective electrode was investigated. A new cesium sensor incorporating Cs-12- molybdophosphate as a sensing materials and DOP as solvent mediator in PVC matrix was constructed and used in the determination of cesium ion in the rage of 10 -5 10 -1 mol 1 -1 with a stop of 46±1.0 mV/decade in Ph range of 4-6

  1. Atmospheric dinitrogen fixation in the flooded rhizosphere as determined by the N-15 isotope technique

    International Nuclear Information System (INIS)

    Yoshida, Tomio; Yoneyama, Tadakatsu.

    1980-01-01

    Atmospheric nitrogen fixation in the rice rhizosphere was determined under in situ conditions of growing flooded rice using the N-15 isotope method. The whole plant growing in a pot at a reproductive stage was placed in a specially designed glass container and exposed to a 15 N 2 atmosphere. The amounts of total nitrogen fixed in the rice rhizosphere under the experimental conditions were 1366, 592, 878, and 698 μg per pot containing 0.4 kg of soil during 15 N 2 exposure for 7 to 13 days in the four experiments conducted in this study. It was also found that the nitrogen fixed in the rice rhizosphere was translocated into other plant parts. Nineteen to 25% of the total atmospheric nitrogen fixed in the rice rhizosphere was found in the roots, leaves and stems, and ears of the rice plants during the 15 N 2 exposure period. (author)

  2. Resonance light scattering technique for the determination of proteins with polymethacrylic acid (PMAA)

    Science.gov (United States)

    Chen, Yanhua; Gao, Dejiang; Tian, Yuan; Ai, Peng; Zhang, Hanqi; Yu, Aimin

    2007-07-01

    As a resonance light scattering (RLS) probe, the polyelectrolyte polymethacrylic acid (PMAA) was applied in this assay. The bovine serum albumin (BSA) and human serum albumin (HSA) were determined by the electrostatic interaction of PMAA and proteins. At pH 3.8 Na 2HPO 4-citric acid buffer solution, the RLS intensities of PMAA-BSA (HSA) system were greatly enhanced. The characteristic peaks were appeared at the wavelength 320, 546 and 594 nm. The optimization conditions of the reaction were also examined and selected. Under the selected conditions, the RLS intensities were proportional to the protein concentrations in the range of (0.0200-2.00) × 10 -6 mol/L for BSA and (0.0200-2.40) × 10 -6 mol/L for HSA. The influences of some foreign substances were also examined. The synthetic samples containing proteins and some real samples were analyzed and the results obtained were satisfactory.

  3. Experimental determination of the thermal contact conductance between two solid surfaces by the energy pulse technique

    International Nuclear Information System (INIS)

    Rubin, Gerson Antonio

    1979-01-01

    An experimental procedure for the determination of the thermal contact conductance between two solid surfaces as a function of the contact pressure and the energy of the laser radiation has been developed using the laser pulse method. A rubi laser with variable energy levels was employed as a radiating pulse energy source. The laser beam was allowed to impinge perpendicularly on the front face of a electrolytic iron 73 4 . The temperature fluctuations resulting on the back surface of the sample was detected by a thermocouple, which Is coupled to a PDP-11/45 Computer 32 Kbytes of memory, through a Analog-Digital Converter. A theoretical function, derived exclusively for the problem mentioned in this work, was adjusted by a method of least square fitting of experimental results. This adjustment yielded the value of a parameter related to the contact conductance between two surfaces. The experimental error obtained for the thermal contact conductance was +- 4.9%. (author)

  4. Multielement determination in Cuban red mangrove samples using nuclear and related analytical techniques

    International Nuclear Information System (INIS)

    Estevez Alvarez, J.R.; Aguiar Lambert, D.; Montero Alvarez, A.; Pupo Gonzalez, I.; Padilla Alvarez, R.; Gonzalez Garcia, H.; Ramirez Sasco, M.

    1998-01-01

    In the present work the contents of Al; K; Ca; Mn; Fe; Ni; Cu; Zn; Sr; Cd and Pb in red mangroves (Rhizophora mangle) from different Cuban regions are determined, using Energy Dispersive X-Ray Fluorescence (Emission-Transmission (Et) and I/C methods), Atomic Absorption Spectrophotometry (AAS), and Polarography (Anodic Stripping Voltametry method). Biological Certified Reference Materials (CRM) are employed for the tracing of the tracing of the curves of the relative I/C method and for the evaluation of the analytical results accuracy. The reliability of the results is also checked by statistical means. Standard deviations and the detection limits of each method are reported. Finally, the obtained values for the concentration of the different elements in each studied ecosystem are presented; a detailed discussion about their significance will be performed in a further paper

  5. Heuristic Optimization Techniques for Determining Optimal Reserve Structure of Power Generating Systems

    DEFF Research Database (Denmark)

    Ding, Yi; Goel, Lalit; Wang, Peng

    2012-01-01

    cost of the system will also increase. The reserve structure of a MSS should be determined based on striking a balance between the required reliability and the reserve cost. The objective of reserve management for a MSS is to schedule the reserve at the minimum system reserve cost while maintaining......Electric power generating systems are typical examples of multi-state systems (MSS). Sufficient reserve is critically important for maintaining generating system reliabilities. The reliability of a system can be increased by increasing the reserve capacity, noting that at the same time the reserve...... the required level of supply reliability to its customers. In previous research, Genetic Algorithm (GA) has been used to solve most reliability optimization problems. However, the GA is not very computationally efficient in some cases. In this chapter a new heuristic optimization technique—the particle swarm...

  6. Applying Fuzzy Logic and Data Mining Techniques in Wireless Sensor Network for Determination Residential Fire Confidence

    Directory of Open Access Journals (Sweden)

    Mirjana Maksimović

    2014-09-01

    Full Text Available The main goal of soft computing technologies (fuzzy logic, neural networks, fuzzy rule-based systems, data mining techniques… is to find and describe the structural patterns in the data in order to try to explain connections between data and on their basis create predictive or descriptive models. Integration of these technologies in sensor nodes seems to be a good idea because it can significantly lead to network performances improvements, above all to reduce the energy consumption and enhance the lifetime of the network. The purpose of this paper is to analyze different algorithms in the case of fire confidence determination in order to see which of the methods and parameter values work best for the given problem. Hence, an analysis between different classification algorithms in a case of nominal and numerical d

  7. Determination of patulin in fruit juices using HPLC-DAD and GC-MSD techniques.

    Science.gov (United States)

    Moukas, Athanasios; Panagiotopoulou, Vasiliki; Markaki, Panagiota

    2008-08-15

    A high performance liquid chromatography with a diode-array detector (HPLC-DAD) and a gas chromatography with a mass spectrometer (GC-MSD) are described for the determination of patulin (PAT) in apple juice. The limits of detection (DL) and quantification (QL) for the HPLC-DAD and GC-MSD method were found to be (DL=0.23μgkg(-1) QL=1.2μgkg(-1)) and (DL=5.8μgkg(-1) and QL=13.8μgkg(-1)), respectively. The recovery factors for HPLC-DAD and GC-MSD were found to be 99.5% (RSD%=0.73) and 41% (RSD%=10.03), respectively. The HPLC-DAD method was used to determine the occurrence of PAT in 90 samples of fruit juices. Results revealed the presence of PAT in 100% of the samples examined. The mean values of PAT in concentrated fruit juices and in the commercial fruit juices collected from the Greek market were found to be 10.54μg PAT kg(-1) and 5.57μg PAT kg(-1) juice, respectively. The most contaminated samples were four concentrated juices ranging from 18.10μg PAT kg(-1) to 36.8μg PAT kg(-1) juice. The daily exposure to patulin for the consumers of all ages in Greece, is ranging from 0.008μg PAT kg(-1) bw to 0.1μg PAT kg(-1) bw if the daily intake of fruit juices is from 0.1 to 0.5kg. With the exception to the most contaminated sample, the daily exposure due to the samples examined, is below the provisional maximum tolerable daily intake for PAT (0.4μg PAT kg(-1) bw). Copyright © 2008 Elsevier Ltd. All rights reserved.

  8. Thermoionic emission characteristics of uranium with application to its determination by MSID technique using 233U tracer

    International Nuclear Information System (INIS)

    Shihomatsu, H.M.; Iyer, S.S.

    1988-01-01

    Experimental details of the uranium determination in geological samples (50-1500 ppm range) by mass spectrometric isotope dilution technique (MSID) employing 233 U tracer are presented. For this purpose the thermoionic emission characteristics of uranium in various filament arrangements like simple plane, filament boat, double, are studied and the most efficient one selected for the isotope dilution analysis. The various experimental procedures involved in the MSID like sample dissolution, chemical separation and mass spectrometric analysis are developed and optimised. The experimental results on the uranium determination by MSID with 233 U tracer yielded precision and accuracy of 0,5% and 1% respectively. The importance of the sampling in the precise and accuracy determination of uranium in geological samples, where it is heterogeneously distributed, is discussed. (author) [pt

  9. Determination of metallic elements in water by the combined preconcentration techniques of ion exchange and atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Paula, M.H. de.

    1981-01-01

    Having as an aim the utilization of atomic absorption method with flame's excitement, the limits of detection in water of six metals (Ag, Co, Cr, Cu, Ni, Zn) were determined in synthetical samples through atomic absorption spectroscopy. Techniques to optimize the data have been pointed out and presented their statistical treatment. By means of the routine and the addition methods three 'real' samples have also been analysed in order to determine the contents of Cu and Zn. Aiming a pre-concentration and by utilizing the 60 Co obtained activating a sample of cobalt in the CDTN/NUCLEBRAS TRIGA MARK-I reactor, the retainement of this cobalt in ion exchange resin and the variation of the factor of elution within different concentration of HCl in water have been determined. The limits of detection are presented and so are the quantitative ones, with and without pre-concentration in an ion exchanger resin and latter elution. (Author) [pt

  10. A technique of using gated-CT images to determine internal target volume (ITV) for fractionated stereotactic lung radiotherapy

    International Nuclear Information System (INIS)

    Jin Jianyue; Ajlouni, Munther; Chen Qing; Yin, Fang-Fang; Movsas, Benjamin

    2006-01-01

    Background and purpose: To develop and evaluate a technique and procedure of using gated-CT images in combination with PET image to determine the internal target volume (ITV), which could reduce the planning target volume (PTV) with adequate target coverage. Patients and methods: A skin marker-based gating system connected to a regular single slice CT scanner was used for this study. A motion phantom with adjustable motion amplitude was used to evaluate the CT gating system. Specifically, objects of various sizes/shapes, considered as virtual tumors, were placed on the phantom to evaluate the number of phases of gated images required to determine the ITV while taking into account tumor size, shape and motion. A procedure of using gated-CT and PET images to define ITV for patients was developed and was tested in patients enrolled in an IRB approved protocol. Results: The CT gating system was capable of removing motion artifacts for target motion as large as 3-cm when it was gated at optimal phases. A phantom study showed that two gated-CT scans at the end of expiration and the end of inspiration would be sufficient to determine the ITV for tumor motion less than 1-cm, and another mid-phase scan would be required for tumors with 2-cm motion, especially for small tumors. For patients, the ITV encompassing visible tumors in all sets of gated-CT and regular spiral CT images seemed to be consistent with the target volume determined from PET images. PTV expanded from the ITV with a setup uncertainty margin had less volume than PTVs from spiral CT images with a 10-mm generalized margin or an individualized margin determined at fluoroscopy. Conclusions: A technique of determining the ITV using gated-CT images was developed and was clinically implemented successfully for fractionated stereotactic lung radiotherapy

  11. Laser-induced breakdown spectroscopy (LIBS) technique for the determination of the chemical composition of complex inorganic materials

    Science.gov (United States)

    Łazarek, Łukasz; Antończak, Arkadiusz J.; Wójcik, Michał R.; Kozioł, Paweł E.; Stepak, Bogusz; Abramski, Krzysztof M.

    2014-08-01

    Laser-induced breakdown spectroscopy (LIBS) is a fast, fully optical method, that needs little or no sample preparation. In this technique qualitative and quantitative analysis is based on comparison. The determination of composition is generally based on the construction of a calibration curve namely the LIBS signal versus the concentration of the analyte. Typically, to calibrate the system, certified reference materials with known elemental composition are used. Nevertheless, such samples due to differences in the overall composition with respect to the used complex inorganic materials can influence significantly on the accuracy. There are also some intermediate factors which can cause imprecision in measurements, such as optical absorption, surface structure, thermal conductivity etc. This paper presents the calibration procedure performed with especially prepared pellets from the tested materials, which composition was previously defined. We also proposed methods of post-processing which allowed for mitigation of the matrix effects and for a reliable and accurate analysis. This technique was implemented for determination of trace elements in industrial copper concentrates standardized by conventional atomic absorption spectroscopy with a flame atomizer. A series of copper flotation concentrate samples was analyzed for contents of three elements, that is silver, cobalt and vanadium. It has been shown that the described technique can be used to qualitative and quantitative analyses of complex inorganic materials, such as copper flotation concentrates.

  12. New technique to determine beta half-lives in complex background conditions

    International Nuclear Information System (INIS)

    Kurtukian-Nieto, T.; Benlliure, J.; Casarejos, E.; Cortina-Gil, D.; Fernandez-Ordonez, M.; Pereira, J.; Schmidt, K.H.; Becker, F.; Henzlova, D.; Yordanov, O.; Audouin, L.; Blank, B.; Giovinazzo, J.; Jurado, B.; Rejmund, F.

    2008-01-01

    Very neutron-rich nuclei near the A = 195 r-process waiting point were produced as projectile fragments from a 208 Pb primary beam at GSI, Darmstadt, by cold fragmentation. After in-flight separation, the fragments were implanted in an active catcher, and time correlations to the subsequent beta-decay were established. Due to the periodic operation cycles of the synchrotron, providing the primary beam, the background shows a complex time structure, which prevents applying well established analytical methods to extract the half-life information. A new mathematical analysis method has been developed, which is based on a Monte Carlo code, simulating the time sequence of implantation and beta detection according to the experimental conditions, leaving the beta lifetimes and the beta detection efficiency as free parameters. In addition, both the analysis of the experimental data and the simulation were performed in time-reversed sequence. The ratio of forward/backward time spectra contains the information of the 'true' fragment-beta correlations. Half-lives were obtained from two-dimensional fits of the measured and simulated ratios of time correlations in forward- and backward-time direction by the least-squares method, being the lifetime and the beta-detection efficiency the two fitting parameters. Half-lives of 8 heavy neutron-rich nuclei approaching the r-process waiting point A = 195 have been determined. (authors)

  13. Exact Cavity Perturbation Technique to Determine Complex Permittivity of Dielectric Materials

    Science.gov (United States)

    Starr, Charles H.; Barmatz, Martin B.

    2011-01-01

    Cassini is an international spacecraft mission facilitated by NASA and ESA which seeks to understand the Saturn planetary system, including rings and moons. Launched in 1997, the Cassini spacecraft contains two major components: the Cassini orbiter that has been orbiting Saturn since October 2004, and the European-built Huygens probe that landed on Titan's surface in December 2004 to study its geology and atmosphere. Titan, Saturn's largest moon and the second largest moon in the solar system, possesses surface and atmospheric features similar to those of Earth, including lakes, seas, and mountains. A physical characterization of these features is critical to understanding the origin and evolution of Titan, whose surface composition reflects its geological history. Because Titan's atmosphere is largely composed of methane, it is believed that surfaces lakes are filled with mixtures of liquid hydrocarbons. The Cassini orbiter's RADAR instrument has been scanning Titan's surface at the atmosphere-penetrating microwave frequency of 13.8 Gigahertz since 2004. However, accurate interpretation of these data is limited by a lack of knowledge regarding dielectric properties of liquid hydrocarbons at cryogenic temperatures. Therefore, it is of specific interest to experimentally determine values for the complex permittivities of various liquid hydrocarbon mixtures at the surface conditions of Titan. In particular, more accurate values for complex permittivity would improve estimates of lake depth and surface composition obtained from the instrument's altimetry and backscatter modes.

  14. Trace elements determination in Syrian honey using x-ray fluorescence technique

    International Nuclear Information System (INIS)

    Khuder, A.; Ahmad, M.; Saour, G.

    2009-05-01

    Major and trace elements of S, Cl, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Rb, Sr in 27 Syrian honey samples, which collected from different areas in the country, in addition to 3 imported honey samples, were determined by dry ashing method for XRF analysis. The samples were diluted and homogenized with a binder made from cellulose powder. The analyzed elements were divided into three groups, relating to the secondary targets used for X-ray excitation. The internal standard method for XRF analysis with a Mo secondary target was used for the determination of the first group of elements: Sr, Rb, Se, As, Zn, Cu, Ni, and Fe. While, the external standard method for XRF analysis with Cu and Ti secondary targets was used for the determination of the second: Mn, Cr, Ti, Ca, K, and third: Cl, and S group of elements, respectively. The results were accurate with a relative standard error less than 4.2 %. The problem of element loss was overcome by the complete drying of honey samples before their ashing. The moisture content was obtained using mass loss and refractive index methods. As a result, the lower limits of detection (LLD) obtained by Mo-XRF was in the range from 0.011 μg Sr/g to 0.064 μg Fe/g, resulting for samples containing 0.1 % ash and collecting live time 1000 s; while, LLD obtained by Cu-XRF was in the range 0.014 μg Mn/g to 0.057 μg K/g. LLD for S and Cl using Ti secondary target was with values of 0.503 μg/g and 1.96 μg/g, respectively. The enhancement factor obtained by drying method for XRF was in the range from 147 to 1667. Normal concentration of elements in Syrian honey was obtained. The concentration of elements was comparable to those obtained by other workers for honeys in different countries. Elements of K, Ca, and Cl were predominantly distributed in all Syrian honey samples. Elements of Sr, Zn, Cu, Fe, Ti, and S were well distributed in all honey samples. While, the concentrations of Rb, Ni, Mn, Cr elements in some honey samples were below the

  15. Simultaneous Analytical Techniques for Determination of 8 Synthetic Food Colors in Foods by HPLC

    Energy Technology Data Exchange (ETDEWEB)

    Park, S.K.; Lee, C.H.; Park, J.S.; Yoon, H.J.; Kim, S.H.; Hong, Y.; Lee, J.O.; Lee, C.W. [Korea Food and Drug Administration, Seoul (Korea)

    2000-06-01

    This Study has been carried out to develop a method of analysis of 8 permitted synthetic food colors [including Brilliant Blue FCF (B1), Indigocarmine (B2), Fast green FCF (G3), Amaranth (R2), Erythrosine (R3), Allura red (R40), Tartrazine (Y4), Sunset Yellow FCF (Y5)] in Korean foods by HPLC. After adjusting to 0.5% HCl, each of the food colors extracted was eluted by Sep-pak C{sub 18} cartridge. Eluates were then determined by high performance liquid chromatograph with a UV-VIS detector. Recoveries of the 8 synthetic food colors were found to be 81.2-98.0% for soft drinks, 80.6-96.1% for candy, 79.8-96.3% for chewing gum, 76.5-91.7% for cereals, 79.0-93.8% for ice cream and 78.6-94.7% for jelly, respectively. The detection limits were 0.05-0.1 {mu}g/g. (author). 24 refs., 2 tabs., 4 figs.

  16. Development of a microindentation technique to determine the fuel mechanical behaviour at high burnup

    International Nuclear Information System (INIS)

    Baron, D.; Leclercq, S.; Spino, J.; Taheri, S.

    1998-01-01

    One of the major problems that face the conceptors and users of nuclear power plants is the demonstration of the cladding integrity (the Zircaloy clad that contains the fuel pellets), particularly in class I and II operating conditions. A long term collaboration between EDF and the Applied Mechanics Laboratory (LMA) of Besancon (France) has existed for several years, and a unified modelling of the cladding has been developed in this frame. But a good understanding of the cladding response is not of total use if the mechanical solicitation applied to this clad by the fuel pellet is not completely known. The potential evolution and the non-homogeneity of the fuel stiffness was recently demonstrated by Spino (TUI) on Vickers micro-hardness tests at room temperature. Thus, in order to get furthermore data, TUI and EDF decided to build a specific microindentation device able to perform the tests needed by the modelers. After a brief recall of what the effects of irradiation are on the fuel pellet mechanical behaviour, this paper presents the microindentation device to be built, as well as the principles that underline its use. Finally, the way the experimental results will be used to determine the mechanical behaviour of the fuel pellet under irradiation is pointed out. (author)

  17. Techniques for detecting and determining risks from low-level radiation

    International Nuclear Information System (INIS)

    Boice, J.D.

    1980-01-01

    Epidemiology is the study of disease in man. In evaluating radiation hazards, analytic studies have utilized the cohort type of investigation (where persons exposed and not exposed to radiation are followed forward in time for determination of disease experience) or case-control approaches (where persons with and without a specific disease are evaluated for previous exposure to radiation). Most radiation studies have evaluated cohorts (e.g., radiologists), although important case-control studies have been conducted (e.g., childhood leukemia as related to prenatal x ray). At its best, epidemiology is capable fo evaluating relative risks (RR) on the order of 1.4 (i.e., a 40% relative excess). However, the RRs of interest following low doses of radiation (1 rad) are on the order of 1.02-1.002. Thus, not much should be anticipated from direct observations at 1 rad, and indirect approaches must be taken to estimate low-dose effects. Such indirect approaches include evaluating 1) populations exposed to a range of doses, both low and high, where interpolation models can be reasonably applied to estimate low-dose effects; and 2) populations exposed to fractionated doses over a long period of time where the resulting dose-effect relationship theoretically should be linear and the estimation of low-level health effects facilitated

  18. Comparison of various extraction techniques for the determination of polycyclic aromatic hydrocarbons in worms.

    Science.gov (United States)

    Mooibroek, D; Hoogerbrugge, R; Stoffelsen, B H G; Dijkman, E; Berkhoff, C J; Hogendoorn, E A

    2002-10-25

    Two less laborious extraction methods, viz. (i) a simplified liquid extraction using light petroleum or (ii) microwave-assisted solvent extraction (MASE), for the analysis of polycyclic aromatic hydrocarbons (PAHs) in samples of the compost worm Eisenia andrei, were compared with a reference method. After extraction and concentration, analytical methodology consisted of a cleanup of (part) of the extract with high-performance gel permeation chromatography (HPGPC) and instrumental analysis of 15 PAHs with reversed-phase liquid chromatography with fluorescence detection (RPLC-FLD). Comparison of the methods was done by analysing samples with incurred residues (n=15, each method) originating from an experiment in which worms were exposed to a soil contaminated with PAHs. Simultaneously, the performance of the total lipid determination of each method was established. Evaluation of the data by means of principal component analysis (PCA) and analysis of variance (ANOVA) revealed that the performance of the light petroleum method for both the extraction of PAHs (concentration range 1-30 ng/g) and lipid content corresponds very well with the reference method. Compared to the reference method, the MASE method yielded somewhat lower concentrations for the less volatile PAHs, e.g., dibenzo[ah]anthracene and benzo[ghi]perylene and provided a significant higher amount of co-extracted material.

  19. Determination of isoniazid concentration in rabbit vertebrae by isotope tracing technique in conjunction with HPLC.

    Science.gov (United States)

    Liu, Peng; Fu, Zhaozong; Jiang, Jianming; Yuan, Liang; Lin, Zhen

    2013-09-01

    Medications compounded with isoniazid (INH) are usually applied to surgical sites at the completion of surgery to locally kill postoperative residual tubercle bacilli. However, the distribution and elimination of INH in the vertebrae in vivo are not known. In this study, isotope tracing was used in conjunction with high-pressure liquid chromatography (HPLC) to address this. INH and technetium-99 m-labeled INH were applied to the vertebrae of rabbits. After 2 and 6 h, osseous tissues containing INH, as determined by radionuclide imaging, were collected for detection with HPLC. The results showed that INH mainly stayed around the vertebrae 6 h after its application and did not permeate widely into the blood or other organs, except for the kidneys. The standard deviations of INH concentrations in the technetium-99 m-INH group were approximately four-fold smaller than those in the INH group. This method of coupling isotope tracing and HPLC can effectively limit experimental error during sample collection, allowing accurate and reliable identification of the concentration levels of INH in osseous tissues in vivo. Copyright © 2013 John Wiley & Sons, Ltd.

  20. Trace and ultratrace analysis methods for the determination of phosphorus by flow-injection techniques.

    Science.gov (United States)

    Motomizu, Shoji; Li, Zhen-Hai

    2005-04-15

    Trace (phosphorus determination by flow-injection analysis are reviewed. Most of the methods cited in this review are fundamentally based on the reaction of orthophosphate with molybdate to form heteropoly acids, such as molybdenum yellow and molybdenum blue, and some of the methods are based on the formation of such secondary reactions as ion associates and their aggregates with bulky cations, such as cationic dyes and quaternary ammonium ions. The heteropoly acids themselves can be measured by spectrophotometry, and the ion associate formed with a cationic dye, Malachite Green (MG), can be measured based on the coloration of MG. Light scattering detection methods can be used for measuring the aggregates of ion associates formed with bulky cations. Highly sensitive detection of phosphorus can be accomplished by fluorophotometry; Rhodamine B (RB) and its analogues react with molybdophosphate to form ion associates, which shows fluorescence quenching of RB: LOD is about 5 nM. The detection method based on the chemiluminescence of luminal oxidized with molybdophosphoric acids is probably the most sensitive of all the detection methods reported so far: LOD of the method is as low as 1nM. The LOD of the molybdenum blue method can be improved by using a liquid core waveguide: LOD is 0.5 nM.

  1. Adaptive Neuro-Fuzzy Computing Technique for Determining Turbulent Flow Friction Coefficient

    Directory of Open Access Journals (Sweden)

    Mohammad Givehchi

    2013-08-01

    Full Text Available Estimation of the friction coefficient in pipes is very important in many water and wastewater engineering issues, such as distribution of velocity and shear stress, erosion, sediment transport and head loss. In analyzing these problems, knowing the friction coefficient, can obtain estimates that are more accurate. In this study in order to estimate the friction coefficient in pipes, using adaptive neuro-fuzzy inference systems (ANFIS, grid partition method was used. For training and testing of neuro-fuzzy model, the data derived from the Colebrook’s equation was used. In the neuro-fuzzy approach, pipe relative roughness and Reynolds number are considered as input variables and friction coefficient as output variable is considered. Performance of the proposed approach was evaluated by using of the data obtained from the Colebrook’s equation and based on statistical indicators such as coefficient determination (R2, root mean squared error (RMSE and mean absolute error (MAE. The results showed that the adaptive nerou-fuzzy inference system with grid partition method and gauss model as an input membership function and linear as an output function could estimate friction coefficient more accurately than other conditions. The new proposed approach in this paper has capability of application in the practical design issues and can be combined with mathematical and numerical models of sediment transfer or real-time updating of these models.

  2. Determination of velocity and flow direction of ground water by using nuclear techniques

    International Nuclear Information System (INIS)

    Santos Ferreira, L. dos.

    1976-06-01

    The dynamics of water in an aquifer with the purpose of determining the filtration velocity and the direction of groundwater flow with radioactive tracers was studied. Field equipment for the purposes of the study was built in the Laboratory of Tracers in Hydrology in collaboration with the Institute of Nuclear Engineering (IEN/NUCLEBRAS). The equipment was designed to minimize the possible vertical flows, loss and molecular diffusion of the tracer out of the studied region. The performance of the nuclear detectors and the constructional details of the field equipament were examined. The selection of the radioactive tracers was made taking into account its availibility and radiation facilities, cost of the inactive material and their physical and chemical properties. The tracers used were 82 Br and 198 Au. The results are discussed with the help of auxiliary informations such as plots of water levels in time and space, profiles and grain analysis. In order to obtain a physical explanation of the results, a qualitative model of the flow in the aquifer is also presented. (Author) [pt

  3. Optimization of the indirect at neutron activation technique for the determination of boron in aqueous solutions

    International Nuclear Information System (INIS)

    Luz, L.C.Q.P. da.

    1984-01-01

    The purpose of this work was the development of an instrumental method for the optimization of the indirect neutron activation analysis of boron in aqueous solutions. The optimization took into account the analytical parameters under laboratory conditions: activation carried out with a 241 Am/Be neutron source and detection of the activity induced in vanadium with two NaI(Tl) gamma spectrometers. A calibration curve was thus obtained for a concentration range of 0 to 5000 ppm B. Later on, experimental models were built in order to study the feasibility of automation. The analysis of boron was finally performed, under the previously established conditions, with an automated system comprising the operations of transport, irradiation and counting. An improvement in the quality of the analysis was observed, with boron concentrations as low as 5 ppm being determined with a precision level better than 0.4%. The experimental model features all basic design elements for an automated device for the analysis of boron in agueous solutions wherever this is required, as in the operation of nuclear reactors. (Author) [pt

  4. Determination of alpha effectiveness in ESR dating using nuclear accelerator techniques: methods and energy dependence

    International Nuclear Information System (INIS)

    Lyons, R.G.

    1988-01-01

    An important parameter in calculating the environmental dose rate for electron spin resonance (ESR) age estimates is the relative effectiveness of alpha and gamma radiation. A small research accelerator is used as a source of alpha particles of various pre-selected energies, corresponding to those found in the environment, to determine the effectiveness of alpha radiation of different energies. Preparation of sample targets is discussed, including the use of absolute ethanol, thorough etching and deposition by centrifuge. Preliminary results show that the alpha/gamma effectiveness ratio, k, depends on the energy of the incident alpha and must therefore be expressed in terms of a reference energy. The effectiveness of an alpha particle in causing ESR damage is found to vary linearly with its range or path length, not with its energy, a fact which must be considered when calculating effective dose-rates from environmental radionuclide concentrations. Failure to do so may lead to serious systematic errors in the effective alpha contribution to environmental dose-rates and consequently in age estimates. (author)

  5. Different Stability-Indicating Chromatographic Techniques for the Determination of Netobimin

    Science.gov (United States)

    Ramadan, Nesrin K.; Mohamed, Afaf O.; Shawky, Sara E.; Salem, Maissa Y.

    2012-01-01

    Two simple, accurate, and sensitive methods were developed for the determination of netobimin in the presence of its degradation product. Method (A) was an HPLC method, performed on C18 column using acetonitrile/methanol/0.01 M potassium dihydrogen phosphate (56 : 14 : 30 by volume) as a mobile phase with a flow rate of 0.5 mL/min. Detection was performed at 254 nm. Method (B) was a TLC method, using silica gel 60 F254 plates; the optimized mobile phase was toluene/methanol/chloroform/ammonium hydroxide (5 : 4 : 6 : 0.1 by volume). The spots were scanned densitometrically at 346 nm. Linearity ranges were 1–10 μg/mL for method (A) and 0.5–5 μg/band for method (B), and the mean percentage recoveries were 99.3 ± 0.7% and 99.7 ± 0.7% for methods (A) and (B), respectively. The proposed methods were found to be specific for netobimin in the presence of up to 90% of its degradation product. Statistical comparison between the results obtained by these methods and the manufacturer method was done, and no significance difference was obtained. PMID:22567566

  6. Different Stability-Indicating Chromatographic Techniques for the Determination of Netobimin

    Directory of Open Access Journals (Sweden)

    Nesrin K. Ramadan

    2012-01-01

    Full Text Available Two simple, accurate, and sensitive methods were developed for the determination of netobimin in the presence of its degradation product. Method (A was an HPLC method, performed on C18 column using acetonitrile/methanol/0.01 M potassium dihydrogen phosphate (56 : 14 : 30 by volume as a mobile phase with a flow rate of 0.5 mL/min. Detection was performed at 254 nm. Method (B was a TLC method, using silica gel 60 F254 plates; the optimized mobile phase was toluene/methanol/chloroform/ammonium hydroxide (5 : 4 : 6 : 0.1 by volume. The spots were scanned densitometrically at 346 nm. Linearity ranges were 1–10 μg/mL for method (A and 0.5–5 μg/band for method (B, and the mean percentage recoveries were 99.3±0.7% and 99.7±0.7% for methods (A and (B, respectively. The proposed methods were found to be specific for netobimin in the presence of up to 90% of its degradation product. Statistical comparison between the results obtained by these methods and the manufacturer method was done, and no significance difference was obtained.

  7. Determination of heat capacity of ionic liquid based nanofluids using group method of data handling technique

    Science.gov (United States)

    Sadi, Maryam

    2018-01-01

    In this study a group method of data handling model has been successfully developed to predict heat capacity of ionic liquid based nanofluids by considering reduced temperature, acentric factor and molecular weight of ionic liquids, and nanoparticle concentration as input parameters. In order to accomplish modeling, 528 experimental data points extracted from the literature have been divided into training and testing subsets. The training set has been used to predict model coefficients and the testing set has been applied for model validation. The ability and accuracy of developed model, has been evaluated by comparison of model predictions with experimental values using different statistical parameters such as coefficient of determination, mean square error and mean absolute percentage error. The mean absolute percentage error of developed model for training and testing sets are 1.38% and 1.66%, respectively, which indicate excellent agreement between model predictions and experimental data. Also, the results estimated by the developed GMDH model exhibit a higher accuracy when compared to the available theoretical correlations.

  8. Review of analytical techniques to determine the chemical forms of vapours and aerosols released from overheated fuel

    International Nuclear Information System (INIS)

    Bowsher, B.R.; Nichols, A.L.

    1989-12-01

    A comprehensive review has been undertaken of appropriate analytical techniques to monitor and measure the chemical effects that occur in large-scale tests designed to study severe reactor accidents. Various methods have been developed to determine the chemical forms of the vapours, aerosols and deposits generated during and after such integral experiments. Other specific techniques have the long-term potential to provide some of the desired data in greater detail, although considerable efforts are still required to apply these techniques to the study of radioactive debris. Such in-situ and post-test methods of analysis have been also assessed in terms of their applicability to the analysis of samples from the Phebus-FP tests. The recommended in-situ methods of analysis are gamma-ray spectroscopy, potentiometry, mass spectrometry, and Raman/UV-visible absorption spectroscopy. Vapour/aerosol and deposition samples should also be obtained at well-defined time intervals during each experiment for subsequent post-test analysis. No single technique can provide all the necessary chemical data from these samples, and the most appropriate method of analysis involves a complementary combination of autoradiography, AES, IR, MRS, SEMS/EDS, SIMS/LMIS, XPS and XRD

  9. Two novel kinetic techniques for determining relative V/K values for alternate substrates

    International Nuclear Information System (INIS)

    Anderson, V.; Kannan, B.

    1986-01-01

    The equilibrium perturbation method of determining kinetic isotope effects has been extended to permit the accurate measurement of relative V/K values for alternate substrates. In the Enoyl-CoA hydratase reaction at pH 8.0 the V/K for trans-2-pentenoyl-CoA (5:1(2t)-CoA) less than 10% greater than V/K for crotonyl-CoA while at pH 4.6 V/K for 5:1(2t)-CoA is over twice the V/K for crotonyl-CoA. This change in the ratio of V/K values indicates that there must be a pKa in the V/K pH profile for 5:1(2t)-CoA that is not characteristic of the free enzyme, a simple interpretation being 5:1(2t)-CoA is a sticky substrate. The pseudoequilibrium perturbation method is inaccurate when the ratio of V/K values exceeds 3. A companion pseudoequilibrium method is introduced where the initial conditions are constrained to produce an initial velocity of zero, rather than requiring the initial and final concentrations of the chromophoric substrate to be identical. The ratio of V/K values is simply the ratio of the concentration of the perturbant molecule to the equilibrium concentration of the nonperturbing analogue. This method combines the advantages of both the equilibrium perturbation method and of initial steady state measurements. The kinetic mechanism of L-3-hydroxyacyl-CoA dehydrogenase, an enzyme whose severe substrate inhibition and small primary 2 H isotope effect have made routine kinetic studies impractical, has been investigated by this method

  10. Use of the electrodeposition technique in the preparation of samples of 237Np and its determination by alpha spectrometry

    International Nuclear Information System (INIS)

    Mertzig, W.; Matsuda, H.T.; Araujo, B.F. de; Araujo, J.A. de.

    1981-05-01

    The electroplating technique to prepare 237 Np source and its determination by alpha spectrometry is presented. The samples were prepared using a lucite-eletrolitic cell manufactured at IPEN, specially to trace amounts of actinides. A polished brass disk coated with Ni film has been used as cathodo and a fixed Pt wire as anode. The electroplated samples were alpha counted using a surface barrier detector. The optimum conditions to obtain the quantitative deposition of 237 Np have been achieved by studying the effects of some parameters as current density, pH and concentration of eletrolitic solution and time of eletrodeposition, using a carrier technique. After preliminary purification, the method is applied to control trace amounts of 237 Np in the Purex process solutions. (Author) [pt

  11. Modification of an impulse-factoring orbital transfer technique to account for orbit determination and maneuver execution errors

    Science.gov (United States)

    Kibler, J. F.; Green, R. N.; Young, G. R.; Kelly, M. G.

    1974-01-01

    A method has previously been developed to satisfy terminal rendezvous and intermediate timing constraints for planetary missions involving orbital operations. The method uses impulse factoring in which a two-impulse transfer is divided into three or four impulses which add one or two intermediate orbits. The periods of the intermediate orbits and the number of revolutions in each orbit are varied to satisfy timing constraints. Techniques are developed to retarget the orbital transfer in the presence of orbit-determination and maneuver-execution errors. Sample results indicate that the nominal transfer can be retargeted with little change in either the magnitude (Delta V) or location of the individual impulses. Additonally, the total Delta V required for the retargeted transfer is little different from that required for the nominal transfer. A digital computer program developed to implement the techniques is described.

  12. An Overview of Analytical Determination of Diltiazem, Cimetidine, Ranitidine, and Famotidine by UV Spectrophotometry and HPLC Technique

    Directory of Open Access Journals (Sweden)

    Nighat Shafi

    2013-01-01

    Full Text Available This review article recapitulates the analytical methods for the quantitative determinations of diltiazem and three H2 receptor antagonists (cimetidine, ranitidine, and famotidine by one of the spectroscopic technique (UV spectrophotometery and separation technique such as high-performance liquid chromatography (HPLC. The clinical and pharmaceutical analysis of these drugs requires effective analytical procedures for quality control, pharmaceutical dosage formulations, and biological fluids. An extensive survey of the literature published in various analytical and pharmaceutical chemistry-related journals has been compiled in its review. A synopsis of reported spectrophotometric and high-performance liquid chromatographic methods for individual drug is integrated. This appraisal illustrates that majority of the HPLC methods reviewed are based on the quantitative analysis of drugs in biological fluids, and they are appropriate for therapeutic drug monitoring purpose.

  13. A Comparative Study of Dispersion Characteristics Determination of a Trapezoidally Corrugated Slow Wave Structure Using Different Techniques

    International Nuclear Information System (INIS)

    Saber, Md. Ghulam; Sagor, Rakibul Hasan; Amin, Md. Ruhul

    2016-01-01

    The linear dispersion relation of a trapezoidally corrugated slow wave structure (TCSWS) is analyzed and presented. The size parameters of the TCSWS are chosen in such a way that they operate in the x-band frequency range. The dispersion relation is solved by utilizing the Rayleigh–Fourier method by expressing the radial function in terms of the Fourier series. A highly accurate synthetic technique is also applied to determine the complete dispersion characteristics from experimentally measured resonances (cold test). Periodic structures resonate at specific frequencies when the terminals are shorted appropriately. The dispersion characteristics obtained from numerical calculation, synthetic technique and cold test are compared, and an excellent agreement is achieved. (paper)

  14. Study of new technique of solid combustible materials to determination of volatile elements by flame atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Campos, R.C. de.

    1988-01-01

    A new technique for direct trace element analysis of solid combustible materials is described. The samples (up to 10 mg) are weighed on a graphite platform wich is then placed in a quartz tube, at the focal point of three infrared lamps. When the lamps are turned on, the sample burns in a stream of air, and the resulting dry aerosol containing volatile elements such as Hg, Cd, Bi, Tl, Zn, Pb and Cu is carried into the mixing chamber and thence into the flame, where the atomic absorption measurement is carried out. This technique overcomes chemical sample preparation steps, avoiding contaminations of losses associated with these steps. A ''furnace in flame'' system where the aerosol is transported to a flame heated T-tube is also described. The influence of flame stoichiometry, observation height, platform material and air flux intensity was studied inorder to determine optimal analytical conditions. (author) [pt

  15. In Situ Determination of Thermal Profiles during Czochralski Silicon Crystal Growth by an Eddy Current Technique.

    Science.gov (United States)

    Choe, Kwang Su.

    An eddy current testing method was developed to continuously monitor crystal growth process and determine thermal profiles in situ during Czochralski silicon crystal growth. The work was motivated by the need to improve the quality of the crystal by controlling thermal gradients and annealing history over the growth cycle. The experimental concept is to monitor intrinsic electrical conductivities of the growing crystal and deduce temperature values from them. The experiments were performed in a resistance-heated Czochralski puller with a 203 mm (8 inch) diameter crucible containing 6.5 kg melt. The silicon crystals being grown were about 80 mm in diameter and monitored by an encircling sensor operating at three different test frequencies (86, 53 and 19 kHz). A one-dimensional analytical solution was employed to translate the detected signals into electrical conductivities. In terms of experiments, the effects of changes in growth condition, which is defined by crystal and crucible rotation rates, crucible position, pull rate, and hot-zone configuration, were investigated. Under a given steady-state condition, the thermal profile was usually stable over the entire length of crystal growth. The profile shifted significantly, however, when the crucible rotation rate was kept too high. As a direct evidence to the effects of melt flow on heat transfer process, a thermal gradient minimum was observed about the crystal/crucible rotation combination of 20/-10 rpm cw. The thermal gradient reduction was still most pronounced when the pull rate or the radiant heat loss to the environment was decreased: a nearly flat axial thermal gradient was achieved when either the pull rate was halved or the height of the exposed crucible wall was effectively doubled. Under these conditions, the average axial thermal gradient along the surface of the crystal was about 4-5 ^{rm o}C/mm. Regardless of growth condition, the three-frequency data revealed radial thermal gradients much larger

  16. Model determination in a case of heterogeneity of variance using sampling techniques.

    Science.gov (United States)

    Varona, L; Moreno, C; Garcia-Cortes, L A; Altarriba, J

    1997-01-12

    A sampling determination procedure has been described in a case of heterogeneity of variance. The procedure makes use of the predictive distributions of each data given the rest of the data and the structure of the assumed model. The computation of these predictive distributions is carried out using a Gibbs Sampling procedure. The final criterion to compare between models is the Mean Square Error between the expectation of predictive distributions and real data. The procedure has been applied to a data set of weight at 210 days in the Spanish Pirenaica beef cattle breed. Three proposed models have been compared: (a) Single Trait Animal Model; (b) Heterogeneous Variance Animal Model; and (c) Multiple Trait Animal Model. After applying the procedure, the most adjusted model was the Heterogeneous Variance Animal Model. This result is probably due to a compromise between the complexity of the model and the amount of available information. The estimated heritabilities under the preferred model have been 0.489 ± 0.076 for males and 0.331 ± 0.082 for females. RESUMEN: Contraste de modelos en un caso de heterogeneidad de varianzas usando métodos de muestreo Se ha descrito un método de contraste de modelos mediante técnicas de muestreo en un caso de heterogeneidad de varianza entre sexos. El procedimiento utiliza las distribucviones predictivas de cada dato, dado el resto de datos y la estructura del modelo. El criterio para coparar modelos es el error cuadrático medio entre la esperanza de las distribuciones predictivas y los datos reales. El procedimiento se ha aplicado en datos de peso a los 210 días en la raza bovina Pirenaica. Se han propuesto tres posibles modelos: (a) Modelo Animal Unicaracter; (b) Modelo Animal con Varianzas Heterogéneas; (c) Modelo Animal Multicaracter. El modelo mejor ajustado fue el Modelo Animal con Varianzas Heterogéneas. Este resultado es probablemente debido a un compromiso entre la complejidad del modelo y la cantidad de datos

  17. Comparison of neutron activation analysis techniques for the determination of uranium concentrations in geological and environmental materials

    International Nuclear Information System (INIS)

    Landsberger, S.; Kapsimalis, R.

    2013-01-01

    We have described the determination of uranium in environmental, geological, and agricultural specimens by three different non-destructive nuclear methods. The effectiveness, as defined as the lower limits of detection in this work, of quantifying trace levels of bulk uranium in geological samples was evaluated for several common NAA techniques. These techniques include short-lived and medium-lived neutron activation analysis using thermal and epithermal neutrons; these results were compared with an assessment of Compton suppressed gamma-ray counting. A careful evaluation of three major (n,γ) reactions with chlorine, manganese and sodium that could impede determining low levels of uranium due to high Compton continuums was done. The evaluation of Compton suppressed passive gamma counting revealed that uranium concentrations below 50 mg kg −1 were not adequate to achieve good counting statistics using the 234m Pa the second daughter product of 238 U. -- Highlights: ► Determination of uranium concentrations in geological, environmental, and agricultural specimens. ► Use of several NAA and passive counting methods. ► Identified several key interferences. ► Use of Compton suppression to minimize effects of interferences

  18. Determination and identification of synthetic cannabinoids and their metabolites in different matrices by modern analytical techniques – a review

    Energy Technology Data Exchange (ETDEWEB)

    Znaleziona, Joanna; Ginterová, Pavlína; Petr, Jan [Regional Centre of Advanced Technologies and Materials, Department of Analytical Chemistry, Faculty of Science, Palacký University, 17. Listopadu 12, Olomouc CZ-77146 (Czech Republic); Ondra, Peter; Válka, Ivo [Department of Forensic Medicine and Medical Law Faculty Hospital, Hněvotínská 3, Olomouc CZ-77146 (Czech Republic); Ševčík, Juraj [Regional Centre of Advanced Technologies and Materials, Department of Analytical Chemistry, Faculty of Science, Palacký University, 17. Listopadu 12, Olomouc CZ-77146 (Czech Republic); Chrastina, Jan [Institute of Special Education Studies, Faculty of Education, Palacký University, Žižkovo náměsti 5, Olomouc CZ-77146 (Czech Republic); Maier, Vítězslav, E-mail: vitezslav.maier@upol.cz [Regional Centre of Advanced Technologies and Materials, Department of Analytical Chemistry, Faculty of Science, Palacký University, 17. Listopadu 12, Olomouc CZ-77146 (Czech Republic)

    2015-05-18

    Highlights: • Synthetic cannabinoids from analytical point of view. • Determination and identification methods of synthetic cannabinoids in different matrices. • Analytical techniques used from thin layer chromatography to high resolution mass spectrometry. • Detailed survey of gas and liquid chromatography methods for synthetic cannabinoids analysis. - Abstract: Synthetic cannabinoids have gained popularity due to their easy accessibility and psychoactive effects. Furthermore, they cannot be detected in urine by routine drug monitoring. The wide range of active ingredients in analyzed matrices hinders the development of a standard analytical method for their determination. Moreover, their possible side effects are not well known which increases the danger. This review is focused on the sample preparation and the determination of synthetic cannabinoids in different matrices (serum, urine, herbal blends, oral fluid, hair) published since 2004. The review includes separation and identification techniques, such as thin layer chromatography, gas and liquid chromatography and capillary electrophoresis, mostly coupled with mass spectrometry. The review also includes results by spectral methods like infrared spectroscopy, nuclear magnetic resonance or direct-injection mass spectrometry.

  19. Determination and identification of synthetic cannabinoids and their metabolites in different matrices by modern analytical techniques – a review

    International Nuclear Information System (INIS)

    Znaleziona, Joanna; Ginterová, Pavlína; Petr, Jan; Ondra, Peter; Válka, Ivo; Ševčík, Juraj; Chrastina, Jan; Maier, Vítězslav

    2015-01-01

    Highlights: • Synthetic cannabinoids from analytical point of view. • Determination and identification methods of synthetic cannabinoids in different matrices. • Analytical techniques used from thin layer chromatography to high resolution mass spectrometry. • Detailed survey of gas and liquid chromatography methods for synthetic cannabinoids analysis. - Abstract: Synthetic cannabinoids have gained popularity due to their easy accessibility and psychoactive effects. Furthermore, they cannot be detected in urine by routine drug monitoring. The wide range of active ingredients in analyzed matrices hinders the development of a standard analytical method for their determination. Moreover, their possible side effects are not well known which increases the danger. This review is focused on the sample preparation and the determination of synthetic cannabinoids in different matrices (serum, urine, herbal blends, oral fluid, hair) published since 2004. The review includes separation and identification techniques, such as thin layer chromatography, gas and liquid chromatography and capillary electrophoresis, mostly coupled with mass spectrometry. The review also includes results by spectral methods like infrared spectroscopy, nuclear magnetic resonance or direct-injection mass spectrometry

  20. Determination of multi-element in marine sediment samples collected in Angola by the k0-NAA technique

    International Nuclear Information System (INIS)

    Teixeira, M.C.P.; Ho Manh Dung; Cao Dong Vu; Nguyen Thi Sy; Nguyen Thanh Binh; Vuong Huu Tan

    2006-01-01

    The marine sediment samples were designed to collect in Angola for marine environmental pollution study. The k 0 -standardization method of neutron activation analysis (k 0 -NAA) on Dalat research reactor has been developed to determine of multi-element in the Angola marine sediment samples. The samples were irradiated in cell 7-1 for short- and middle-lived nuclides and rotary specimen rack for long-lived nuclides. The irradiation facilities were characterized for neutron spectrum parameters and post-activated samples were measured on the calibrated gamma-ray spectrometers using HPGe detectors. The analytical results for 9 marine sediment samples with 27 elements: Al, As, Br, Ca, Ce,Cl, Co, Cs, Dy, Fe, Hf, I, K, Mg, Mn, Na, Rb, Sb, Sc, Se, Sm, Th, Ti, U, V and Zn in term of mean concentration, standard deviation and their content range are shown in the report. The analytical quality assurance was done by analysis of a Japan's certified reference material namely marine sediment NMIJ-CRM-7302a. These preliminary results revealed that the k 0 -NAA technique on the Dalat research reactor is a good analytical technique for determination of multi-element in the marine sediment samples. Some heavy metals and trace elements determined in this work possibly connected to the human activities at the sampling region. (author)