WorldWideScience

Sample records for breast imaging system

  1. Prototype of Microwave Imaging System for Breast-Cancer Screening

    DEFF Research Database (Denmark)

    Rubæk, Tonny; Zhurbenko, Vitaliy

    2009-01-01

    Microwave imaging for breast-cancer detection has received the attention of a large number of research groups in the last decade. In this paper, the imaging system currently being developed at the Technical university of Denmark is presented. This includes a description of the antenna system, the...

  2. Microwave Breast Imaging Techniques

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Rubæk, Tonny

    2010-01-01

    This paper outlines the applicability of microwave radiation for breast cancer detection. Microwave imaging systems are categorized based on their hardware architecture. The advantages and disadvantages of various imaging techniques are discussed. The fundamental tradeoffs are indicated between...

  3. Observer detection limits for a dedicated SPECT breast imaging system

    OpenAIRE

    Cutler, S J; Perez, K L; Barnhart, H. X.; Tornai, M P

    2010-01-01

    An observer-based contrast-detail study is performed in an effort to evaluate the limits of object detectability using a dedicated CZT-based breast SPECT imaging system under various imaging conditions. A custom geometric contrast-resolution phantom was developed that can be used for both positive (‘hot’) and negative contrasts (‘cold’). The 3 cm long fillable tubes are arranged in six sectors having equal inner diameters ranging from 1 mm to 6 mm with plastic wall thicknesses of

  4. Observer detection limits for a dedicated SPECT breast imaging system

    Science.gov (United States)

    Cutler, S. J.; Perez, K. L.; Barnhart, H. X.; Tornai, M. P.

    2010-04-01

    An observer-based contrast-detail study is performed in an effort to evaluate the limits of object detectability using a dedicated CZT-based breast SPECT imaging system under various imaging conditions. A custom geometric contrast-resolution phantom was developed that can be used for both positive ('hot') and negative contrasts ('cold'). The 3 cm long fillable tubes are arranged in six sectors having equal inner diameters ranging from 1 mm to 6 mm with plastic wall thicknesses of SPECT camera having 2.5 mm intrinsic pixels, the mean detectable rod was ~3.4 mm at a 10:1 ratio, degrading to ~5.2 mm with the 2.5:1 concentration ratio. The smallest object detail was observed using a 45° tilted trajectory acquisition. The complex 3D projected sine wave acquisition, however, had the most consistent combined intra- and inter-observer results, making it potentially the best imaging approach for consistent results.

  5. Breast imaging

    International Nuclear Information System (INIS)

    The majority of information available today indiates that the most efficient and accurate method of screening women to detect early-stage breast cancer is an aggressive program of patient self-examination, physical examination by well-trained, motivated personnel, and high-quality x-ray mammography. There are two important factors in the implementation of mammographic screening. The first is the availability of facilities to perform high-quality, low-dose mammography, which is directly related to the second factor: the expense to society for support of this large-scale effort. Cost-benefit analysis is beyond the scope of this review. In 1979 Moskowitz and Fox attempted to address this issue, using data from the Breast Cancer Detection Demonstration Project in Cincinnati, but additional analysis is required. The cost for each ''curable'' cancer that is detected must be compared with the psychological, social, and personal losses that accrue, as well as the numerous medical expenses incurred, in a frequently protracted death from breast cancer. All other imaging techniques that have been reviewed should be regarded as adjuncts to rather than replacements for mammographic screening. Ultrasound and computerized tomography are helpful when the physical examination and mammogram are equivocal. Other techniques, such as transillumination, thermography, and magnetic-resonance imaging, should be considered experimental. In patients with clinically evident lesions, x-ray mammography is helpful to evaluate the suspicious area, as well as to ''screen'' the remaining tissue in both breasts and to search for multicentric or bilateral lesions. Mammography is the only imaging technique that has been proved effective for screening

  6. Value of breast imaging reporting and data system in Chinese breast cancer screening

    International Nuclear Information System (INIS)

    Objective: To study the value of breast imaging reporting and data system (BI-RADS) in Chinese breast cancer screening. Methods: A total number of 3483 women participated in breast cancer screening with mammography in Hexi district in Tianjin from August to December 2009, which was organized by ministry of public health. BI-RADS assessment categories and recommendations were compared with histological findings. The precision, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. Results: Among 3483 screening mammography cases, 267 were almost entirely fat breast, 1245 were scattered fibroglandular, 1890 were dense and 81 extremely dense. There were 1011 patients (29.0%) with category 1, 1741 (50.0%) with category 2, 383 (11.0%) with category 3, 59 patients (1.7%) with category 4 and 16 (0.5%) with category 5 according to BI-RADS assessment categories. Totally, 71 women with 77 lesions were confirmed by histological examinations. There were 29 malignant and 48 benign lesions. The diagnostic precision, sensitivity, specificity of' BI-RADS were 63.6% (49/77), 93.1% (27/29) and 45.8% (22/48). The general PPV of BI-RADS was 50.9% (27/53). The PPV of categories 0.4, 5 were 25.0% (1/4), 36.4% (12/33) and 87.5% (14/16). The NPV of categories 2 and 3 were 90.9% (10/11), 100.0% (12/12). Conclusions: BI-RADS is of much value in assessing the breast malignancy. It is applicable in Chinese breast cancer screening. (authors)

  7. Observer detection limits for a dedicated SPECT breast imaging system

    International Nuclear Information System (INIS)

    An observer-based contrast-detail study is performed in an effort to evaluate the limits of object detectability using a dedicated CZT-based breast SPECT imaging system under various imaging conditions. A custom geometric contrast-resolution phantom was developed that can be used for both positive ('hot') and negative contrasts ('cold'). The 3 cm long fillable tubes are arranged in six sectors having equal inner diameters ranging from 1 mm to 6 mm with plastic wall thicknesses of <0.25 mm, on a pitch of twice their inner diameters. Scans of the activity filled tubes using simple circular trajectories are obtained in a 215 mL uniform water filled cylinder, varying the rod:background concentration ratios from 10:1 to 1:10 simulating a large range of biological uptake ratios. The rod phantom is then placed inside a non-uniformly shaped 500 mL breast phantom and scans are again acquired using both simple and complex 3D trajectories for similarly varying contrasts. Summed slice and contiguous multi-slice images are evaluated by five independent readers, identifying the smallest distinguishable rod for each concentration and experimental setup. Linear and quadratic regression is used to compare the resulting contrast-detail curves. Results indicate that in a moderately low-noise 500 mL background, using the SPECT camera having 2.5 mm intrinsic pixels, the mean detectable rod was ∼3.4 mm at a 10:1 ratio, degrading to ∼5.2 mm with the 2.5:1 concentration ratio. The smallest object detail was observed using a 45 deg. tilted trajectory acquisition. The complex 3D projected sine wave acquisition, however, had the most consistent combined intra- and inter-observer results, making it potentially the best imaging approach for consistent results.

  8. Observer detection limits for a dedicated SPECT breast imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Cutler, S J; Tornai, M P [Department of Biomedical Engineering, Duke University, Durham, NC 27708 (United States); Perez, K L [Department of Radiology, Duke University Medical Center, Durham, NC 27710 (United States); Barnhart, H X [Department of Biostatistics and Bioinformatics, Duke University, Durham, NC 27715 (United States)], E-mail: spencer.cutler@duke.edu

    2010-04-07

    An observer-based contrast-detail study is performed in an effort to evaluate the limits of object detectability using a dedicated CZT-based breast SPECT imaging system under various imaging conditions. A custom geometric contrast-resolution phantom was developed that can be used for both positive ('hot') and negative contrasts ('cold'). The 3 cm long fillable tubes are arranged in six sectors having equal inner diameters ranging from 1 mm to 6 mm with plastic wall thicknesses of <0.25 mm, on a pitch of twice their inner diameters. Scans of the activity filled tubes using simple circular trajectories are obtained in a 215 mL uniform water filled cylinder, varying the rod:background concentration ratios from 10:1 to 1:10 simulating a large range of biological uptake ratios. The rod phantom is then placed inside a non-uniformly shaped 500 mL breast phantom and scans are again acquired using both simple and complex 3D trajectories for similarly varying contrasts. Summed slice and contiguous multi-slice images are evaluated by five independent readers, identifying the smallest distinguishable rod for each concentration and experimental setup. Linear and quadratic regression is used to compare the resulting contrast-detail curves. Results indicate that in a moderately low-noise 500 mL background, using the SPECT camera having 2.5 mm intrinsic pixels, the mean detectable rod was {approx}3.4 mm at a 10:1 ratio, degrading to {approx}5.2 mm with the 2.5:1 concentration ratio. The smallest object detail was observed using a 45 deg. tilted trajectory acquisition. The complex 3D projected sine wave acquisition, however, had the most consistent combined intra- and inter-observer results, making it potentially the best imaging approach for consistent results.

  9. Ultrashort Microwave-Pumped Real-Time Thermoacoustic Breast Tumor Imaging System.

    Science.gov (United States)

    Ye, Fanghao; Ji, Zhong; Ding, Wenzheng; Lou, Cunguang; Yang, Sihua; Xing, Da

    2016-03-01

    We report the design of a real-time thermoacoustic (TA) scanner dedicated to imaging deep breast tumors and investigate its imaging performance. The TA imaging system is composed of an ultrashort microwave pulse generator and a ring transducer array with 384 elements. By vertically scanning the transducer array that encircles the breast phantom, we achieve real-time, 3D thermoacoustic imaging (TAI) with an imaging speed of 16.7 frames per second. The stability of the microwave energy and its distribution in the cling-skin acoustic coupling cup are measured. The results indicate that there is a nearly uniform electromagnetic field in each XY-imaging plane. Three plastic tubes filled with salt water are imaged dynamically to evaluate the real-time performance of our system, followed by 3D imaging of an excised breast tumor embedded in a breast phantom. Finally, to demonstrate the potential for clinical applications, the excised breast of a ewe embedded with an ex vivo human breast tumor is imaged clearly with a contrast of about 1:2.8. The high imaging speed, large field of view, and 3D imaging performance of our dedicated TAI system provide the potential for clinical routine breast screening. PMID:26552081

  10. Imaging male breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Doyle, S., E-mail: sdoyle2@nhs.net [Primrose Breast Care Unit, Derriford Hospital, Plymouth (United Kingdom); Steel, J.; Porter, G. [Primrose Breast Care Unit, Derriford Hospital, Plymouth (United Kingdom)

    2011-11-15

    Male breast cancer is rare, with some pathological and radiological differences from female breast cancer. There is less familiarity with the imaging appearances of male breast cancer, due to its rarity and the more variable use of preoperative imaging. This review will illustrate the commonest imaging appearances of male breast cancer, with emphasis on differences from female breast cancer and potential pitfalls in diagnosis, based on a 10 year experience in our institution.

  11. Computational Validation of a 3-D Microwave Imaging System for Breast-Cancer Screening

    DEFF Research Database (Denmark)

    Rubæk, Tonny; Kim, Oleksiy S.; Meincke, Peter

    2009-01-01

    signals improves its performance when compared to the more commonly used complex phasor formulation. This improvement is illustrated by imaging a simulated hemispherical breast model using both formulations. In addition to this, the importance of using the correct position and orientation of the antennas...... in the measurement system is shown by imaging the same breast model using a measurement setup in which the antennas are vertically oriented....

  12. An Object-Oriented Simulator for 3D Digital Breast Tomosynthesis Imaging System

    Directory of Open Access Journals (Sweden)

    Saeed Seyyedi

    2013-01-01

    Full Text Available Digital breast tomosynthesis (DBT is an innovative imaging modality that provides 3D reconstructed images of breast to detect the breast cancer. Projections obtained with an X-ray source moving in a limited angle interval are used to reconstruct 3D image of breast. Several reconstruction algorithms are available for DBT imaging. Filtered back projection algorithm has traditionally been used to reconstruct images from projections. Iterative reconstruction algorithms such as algebraic reconstruction technique (ART were later developed. Recently, compressed sensing based methods have been proposed in tomosynthesis imaging problem. We have developed an object-oriented simulator for 3D digital breast tomosynthesis (DBT imaging system using C++ programming language. The simulator is capable of implementing different iterative and compressed sensing based reconstruction methods on 3D digital tomosynthesis data sets and phantom models. A user friendly graphical user interface (GUI helps users to select and run the desired methods on the designed phantom models or real data sets. The simulator has been tested on a phantom study that simulates breast tomosynthesis imaging problem. Results obtained with various methods including algebraic reconstruction technique (ART and total variation regularized reconstruction techniques (ART+TV are presented. Reconstruction results of the methods are compared both visually and quantitatively by evaluating performances of the methods using mean structural similarity (MSSIM values.

  13. Phantom experiments with a microwave imaging system for breast-cancer screening

    DEFF Research Database (Denmark)

    Rubæk, Tonny; Zhurbenko, Vitaliy

    2009-01-01

    Microwave imaging is emerging as a promising technique for breast-cancer detection. In this paper, the microwave imaging system currently being developed at the Technical University of Denmark is introduced. This system consists of 32 antennas positioned in a cylindrical setup, each equipped with...

  14. Challenges in the Design of Microwave Imaging Systems for Breast Cancer Detection

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy

    2011-01-01

    community. This paper presents the survey of the ongoing research in the field of microwave imaging of biological tissues, with major focus on the breast tumor detection application. The existing microwave imaging systems are categorized on the basis of the employed measurement concepts. The advantages and...

  15. Breast Imaging Reporting and Data System (BI-RADS) breast composition descriptors: Automated measurement development for full field digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, E. E.; Sellers, T. A.; Lu, B. [Department of Cancer Epidemiology, Division of Population Sciences, H. Lee Moffitt Cancer Center, Tampa, Florida 33612 (United States); Heine, J. J. [Department of Cancer Imaging and Metabolism, H. Lee Moffitt Cancer Center, Tampa, Florida 33612 (United States)

    2013-11-15

    Purpose: The Breast Imaging Reporting and Data System (BI-RADS) breast composition descriptors are used for standardized mammographic reporting and are assessed visually. This reporting is clinically relevant because breast composition can impact mammographic sensitivity and is a breast cancer risk factor. New techniques are presented and evaluated for generating automated BI-RADS breast composition descriptors using both raw and calibrated full field digital mammography (FFDM) image data.Methods: A matched case-control dataset with FFDM images was used to develop three automated measures for the BI-RADS breast composition descriptors. Histograms of each calibrated mammogram in the percent glandular (pg) representation were processed to create the new BR{sub pg} measure. Two previously validated measures of breast density derived from calibrated and raw mammograms were converted to the new BR{sub vc} and BR{sub vr} measures, respectively. These three measures were compared with the radiologist-reported BI-RADS compositions assessments from the patient records. The authors used two optimization strategies with differential evolution to create these measures: method-1 used breast cancer status; and method-2 matched the reported BI-RADS descriptors. Weighted kappa (κ) analysis was used to assess the agreement between the new measures and the reported measures. Each measure's association with breast cancer was evaluated with odds ratios (ORs) adjusted for body mass index, breast area, and menopausal status. ORs were estimated as per unit increase with 95% confidence intervals.Results: The three BI-RADS measures generated by method-1 had κ between 0.25–0.34. These measures were significantly associated with breast cancer status in the adjusted models: (a) OR = 1.87 (1.34, 2.59) for BR{sub pg}; (b) OR = 1.93 (1.36, 2.74) for BR{sub vc}; and (c) OR = 1.37 (1.05, 1.80) for BR{sub vr}. The measures generated by method-2 had κ between 0.42–0.45. Two of these

  16. An Artificial Immune System-Based Support Vector Machine Approach for Classifying Ultrasound Breast Tumor Images.

    Science.gov (United States)

    Wu, Wen-Jie; Lin, Shih-Wei; Moon, Woo Kyung

    2015-10-01

    A rapid and highly accurate diagnostic tool for distinguishing benign tumors from malignant ones is required owing to the high incidence of breast cancer. Although various computer-aided diagnosis (CAD) systems have been developed to interpret ultrasound images of breast tumors, feature selection and the setting of parameters are still essential to classification accuracy and the minimization of computational complexity. This work develops a highly accurate CAD system that is based on a support vector machine (SVM) and the artificial immune system (AIS) algorithm for evaluating breast tumors. Experiments demonstrate that the accuracy of the proposed CAD system for classifying breast tumors is 96.67%. The sensitivity, specificity, PPV, and NPV of the proposed CAD system are 96.67, 96.67, 95.60, and 97.48%, respectively. The receiver operator characteristic (ROC) area index A z is 0.9827. Hence, the proposed CAD system can reduce the number of biopsies and yield useful results that assist physicians in diagnosing breast tumors. PMID:25561066

  17. A mathematical model platform for optimizing a multiprojection breast imaging system.

    Science.gov (United States)

    Chawla, Amarpreet S; Samei, Ehsan; Saunders, Robert S; Lo, Joseph Y; Baker, Jay A

    2008-04-01

    Multiprojection imaging is a technique in which a plurality of digital radiographic images of the same patient are acquired within a short interval of time from slightly different angles. Information from each image is combined to determine the final diagnosis. Projection data are either reconstructed into slices as in the case of tomosynthesis or analyzed directly as in the case of multiprojection correlation imaging technique, thereby avoiding reconstruction artifacts. In this study, the authors investigated the optimum geometry of acquisitions of a multiprojection breast correlation imaging system in terms of the number of projections and their total angular span that yield maximum performance in a task that models clinical decision. Twenty-five angular projections of each breast from 82 human subjects in our breast tomosynthesis database were each supplemented with a simulated 3 mm mass. An approach based on Laguerre-Gauss channelized Hotelling observer was developed to assess the detectability of the mass in terms of receiver operating characteristic (ROC) curves. Two methodologies were developed to integrate results from individual projections into one combined ROC curve as the overall figure of merit. To optimize the acquisition geometry, different components of acquisitions were changed to investigate which one of the many possible configurations maximized the area under the combined ROC curve. Optimization was investigated under two acquisition dose conditions corresponding to a fixed total dose delivered to the patient and a variable dose condition, based on the number of projections used. In either case, the detectability was dependent on the number of projections used, the total angular span of those projections, and the acquisition dose level. In the first case, the detectability approximately followed a bell curve as a function of the number of projections with the maximum between 8 and 16 projections spanning angular arcs of about 23 degrees-45

  18. Validity of breast-specific gamma imaging for Breast Imaging Reporting and Data System 4 lesions on mammography and/or ultrasound

    Science.gov (United States)

    Cho, Min Jeng; Yu, Yeong Beom; Park, Kyoung Sik; Chung, Hyun Woo; So, Young; Choi, Nami; Kim, Mi Young

    2016-01-01

    Purpose The purpose of this study was to assess the breast-specific gamma imaging (BSGI) in Breast Imaging Reporting and Data System (BI-RADS) 4 lesions on mammography and/or ultrasound. Methods We performed a retrospective review of 162 patients who underwent BSGI in BI-RADS 4 lesions on mammography and/or ultrasound. Results Of the 162 breast lesions, 66 were malignant tumors and 96 were benign tumors. Sensitivity and specificity of BSGI were 90.9% and 78.1%, and positive predictive value and negative predictive value were 74.1% and 92.6%. The sensitivity or specificity of mammography and ultrasound were 74.2% and 56.3% and 87.9% and 19.8%, respectively. The sensitivity and specificity of BSGI for breast lesions ≤1 cm were 88.0% and 86.8%, while the values of beast lesions >1 cm were 92.7% and 61.5%. The sensitivity or specificity of BSGI and mammography for patients with dense breasts were 92.0% and 81.3% and 72.0% and 50.0%, respectively. 26 patients showed neither a nodule nor microcalcification on ultrasound, but showed suspicious calcification on mammography. The sensitivity and specificity of BSGI with microcalcification only lesion were 75.0% and 94.4%. Conclusion This study demonstrated that BSGI had shown high sensitivity and specificity, as well as positive and negative predictive values in BI-RADS 4 lesions on ultrasound and/or mammography. BSGI showed excellent results in dense breasts, in lesions that are less than 1 cm in size and lesions with suspicious microcalcification only. PMID:27073789

  19. Analysis of breast imaging reporting and data system category 4 complex cystic masses of the breast: Do all the complex cystic breast masses merit a biopsy?

    International Nuclear Information System (INIS)

    To investigate whether sonographic findings can predict malignancy in complex echoic breast masses using the Breast Imaging Reporting and Data System (BI-RADS) lexicon and to demonstrate the need for biopsy recommendations for all complex breast masses. 135 pathologically proven complex echoic masses detected on sonography were identified. We retrospectively reviewed the sonographic findings according to the BI-RADS lexicon which include shape, margin, orientation, lesion boundary, posterior acoustic features, and vascularity. The sonographic findings were correlated with the pathology and mammographic findings. Differentiation between the sonographic appearance of benign and malignant complex cystic lesions was evaluated using the chi-square test or the Mann-Whitney U test. 59.3% (80/135) were benign lesions and 40.7% (55/135) were malignant lesions. Malignant lesions were correlated with irregular (p < 0.001), nonparallel (p = 0.023), noncircumscribed (p < 0.001), echogenic halo (p < 0.001), increased vascularity (p = 0.001) and large size (p = 0.002) compared to benign lesions. However, 12.7% (7/55) of benign looking complex cystic masses were proved to be malignant. All seven lesions had malignant microcalcifications or abnormality on mammography. Using the sonographic BI-RADS lexicon can be useful for differentiating between malignant and benign complex cystic breast masses. Notably, 12.7% of the complex cystic lesions showing a benign appearance on sonography were pathologically proven malignant. Therefore, radiologist should recommend biopsy for complex cystic lesions.

  20. Classification System for Identifying Women at Risk for Altered Partial Breast Irradiation Recommendations After Breast Magnetic Resonance Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kowalchik, Kristin V. [Department of Radiation Oncology, Mayo Clinic, Jacksonville, Florida (United States); Vallow, Laura A., E-mail: vallow.laura@mayo.edu [Department of Radiation Oncology, Mayo Clinic, Jacksonville, Florida (United States); McDonough, Michelle [Department of Radiology, Mayo Clinic, Jacksonville, Florida (United States); Thomas, Colleen S.; Heckman, Michael G. [Section of Biostatistics, Mayo Clinic, Jacksonville, Florida (United States); Peterson, Jennifer L. [Department of Radiation Oncology, Mayo Clinic, Jacksonville, Florida (United States); Adkisson, Cameron D. [Department of General Surgery, Mayo Clinic, Jacksonville, Florida (United States); Serago, Christopher [Department of Radiation Oncology, Mayo Clinic, Jacksonville, Florida (United States); McLaughlin, Sarah A. [Department of General Surgery, Mayo Clinic, Jacksonville, Florida (United States)

    2013-09-01

    Purpose: To study the utility of preoperative breast MRI for partial breast irradiation (PBI) patient selection, using multivariable analysis of significant risk factors to create a classification rule. Methods and Materials: Between 2002 and 2009, 712 women with newly diagnosed breast cancer underwent preoperative bilateral breast MRI at Mayo Clinic Florida. Of this cohort, 566 were retrospectively deemed eligible for PBI according to the National Surgical Adjuvant Breast and Bowel Project Protocol B-39 inclusion criteria using physical examination, mammogram, and/or ultrasound. Magnetic resonance images were then reviewed to determine their impact on patient eligibility. The patient and tumor characteristics were evaluated to determine risk factors for altered PBI eligibility after MRI and to create a classification rule. Results: Of the 566 patients initially eligible for PBI, 141 (25%) were found ineligible because of pathologically proven MRI findings. Magnetic resonance imaging detected additional ipsilateral breast cancer in 118 (21%). Of these, 62 (11%) had more extensive disease than originally noted before MRI, and 64 (11%) had multicentric disease. Contralateral breast cancer was detected in 28 (5%). Four characteristics were found to be significantly associated with PBI ineligibility after MRI on multivariable analysis: premenopausal status (P=.021), detection by palpation (P<.001), first-degree relative with a history of breast cancer (P=.033), and lobular histology (P=.002). Risk factors were assigned a score of 0-2. The risk of altered PBI eligibility from MRI based on number of risk factors was 0:18%; 1:22%; 2:42%; 3:65%. Conclusions: Preoperative bilateral breast MRI altered the PBI recommendations for 25% of women. Women who may undergo PBI should be considered for breast MRI, especially those with lobular histology or with 2 or more of the following risk factors: premenopausal, detection by palpation, and first-degree relative with a history of

  1. Classification System for Identifying Women at Risk for Altered Partial Breast Irradiation Recommendations After Breast Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Purpose: To study the utility of preoperative breast MRI for partial breast irradiation (PBI) patient selection, using multivariable analysis of significant risk factors to create a classification rule. Methods and Materials: Between 2002 and 2009, 712 women with newly diagnosed breast cancer underwent preoperative bilateral breast MRI at Mayo Clinic Florida. Of this cohort, 566 were retrospectively deemed eligible for PBI according to the National Surgical Adjuvant Breast and Bowel Project Protocol B-39 inclusion criteria using physical examination, mammogram, and/or ultrasound. Magnetic resonance images were then reviewed to determine their impact on patient eligibility. The patient and tumor characteristics were evaluated to determine risk factors for altered PBI eligibility after MRI and to create a classification rule. Results: Of the 566 patients initially eligible for PBI, 141 (25%) were found ineligible because of pathologically proven MRI findings. Magnetic resonance imaging detected additional ipsilateral breast cancer in 118 (21%). Of these, 62 (11%) had more extensive disease than originally noted before MRI, and 64 (11%) had multicentric disease. Contralateral breast cancer was detected in 28 (5%). Four characteristics were found to be significantly associated with PBI ineligibility after MRI on multivariable analysis: premenopausal status (P=.021), detection by palpation (P<.001), first-degree relative with a history of breast cancer (P=.033), and lobular histology (P=.002). Risk factors were assigned a score of 0-2. The risk of altered PBI eligibility from MRI based on number of risk factors was 0:18%; 1:22%; 2:42%; 3:65%. Conclusions: Preoperative bilateral breast MRI altered the PBI recommendations for 25% of women. Women who may undergo PBI should be considered for breast MRI, especially those with lobular histology or with 2 or more of the following risk factors: premenopausal, detection by palpation, and first-degree relative with a history of

  2. Imaging results of multi-modal ultrasound computerized tomography system designed for breast diagnosis.

    Science.gov (United States)

    Opieliński, Krzysztof J; Pruchnicki, Piotr; Gudra, Tadeusz; Podgórski, Przemysław; Kurcz, Jacek; Kraśnicki, Tomasz; Sąsiadek, Marek; Majewski, Jarosław

    2015-12-01

    Nowadays, in the era of common computerization, transmission and reflection methods are intensively developed in addition to improving classical ultrasound methods (US) for imaging of tissue structure, in particular ultrasound transmission tomography UTT (analogous to computed tomography CT which uses X-rays) and reflection tomography URT (based on the synthetic aperture method used in radar imaging techniques). This paper presents and analyses the results of ultrasound transmission tomography imaging of the internal structure of the female breast biopsy phantom CIRS Model 052A and the results of the ultrasound reflection tomography imaging of a wire sample. Imaging was performed using a multi-modal ultrasound computerized tomography system developed with the participation of a private investor. The results were compared with the results of imaging obtained using dual energy CT, MR mammography and conventional US method. The obtained results indicate that the developed UTT and URT methods, after the acceleration of the scanning process, thus enabling in vivo examination, may be successfully used for detection and detailed characterization of breast lesions in women. PMID:25759234

  3. Clear-PEM: A PET imaging system dedicated to breast cancer diagnostics

    CERN Document Server

    Abreu, M C; Albuquerque, E; Almeida, F G; Almeida, P; Amaral, P; Auffray, Etiennette; Bento, P; Bruyndonckx, P; Bugalho, R; Carriço, B; Cordeiro, H; Ferreira, M; Ferreira, N C; Gonçalves, F; Lecoq, Paul; Leong, C; Lopes, F; Lousã, P; Luyten, J; Martins, M V; Matela, N; Rato-Mendes, P; Moura, R; Nobre, J; Oliveira, N; Ortigão, C; Peralta, L; Rego, J; Ribeiro, R; Rodrigues, P; Santos, A I; Silva, J C; Silva, M M; Tavernier, Stefaan; Teixeira, I C; Texeira, J P; Trindade, A; Trummer, Julia; Varela, J

    2007-01-01

    The Clear-PEM scanner for positron emission mammography under development is described. The detector is based on pixelized LYSO crystals optically coupled to avalanche photodiodes and readout by a fast low-noise electronic system. A dedicated digital trigger (TGR) and data acquisition (DAQ) system is used for on-line selection of coincidence events with high efficiency, large bandwidth and small dead-time. A specialized gantry allows to perform exams of the breast and of the axilla. In this paper we present results of the measurement of detector modules that integrate the system under construction as well as the imaging performance estimated from Monte Carlo simulated data.

  4. Collimator design for a dedicated molecular breast imaging-guided biopsy system: Proof-of-concept

    International Nuclear Information System (INIS)

    Purpose: Molecular breast imaging (MBI) is a dedicated nuclear medicine breast imaging modality that employs dual-head cadmium zinc telluride (CZT) gamma cameras to functionally detect breast cancer. MBI has been shown to detect breast cancers otherwise occult on mammography and ultrasound. Currently, a MBI-guided biopsy system does not exist to biopsy such lesions. Our objective was to consider the utility of a novel conical slant-hole (CSH) collimator for rapid (<1 min) and accurate monitoring of lesion position to serve as part of a MBI-guided biopsy system. Methods: An initial CSH collimator design was derived from the dimensions of a parallel-hole collimator optimized for MBI performed with dual-head CZT gamma cameras. The parameters of the CSH collimator included the collimator height, cone slant angle, thickness of septa and cones of the collimator, and the annular areas exposed at the base of the cones. These parameters were varied within the geometric constraints of the MBI system to create several potential CSH collimator designs. The CSH collimator designs were evaluated using Monte Carlo simulations. The model included a breast compressed to a thickness of 6 cm with a 1-cm diameter lesion located 3 cm from the collimator face. The number of particles simulated was chosen to represent the count density of a low-dose, screening MBI study acquired with the parallel-hole collimator for 10 min after a ∼150 MBq (4 mCi) injection of Tc-99m sestamibi. The same number of particles was used for the CSH collimator simulations. In the resulting simulated images, the count sensitivity, spatial resolution, and accuracy of the lesion depth determined from the lesion profile width were evaluated. Results: The CSH collimator design with default parameters derived from the optimal parallel-hole collimator provided 1-min images with error in the lesion depth estimation of 1.1 ± 0.7 mm and over 21 times the lesion count sensitivity relative to 1-min images acquired with

  5. Collimator design for a dedicated molecular breast imaging-guided biopsy system: Proof-of-concept

    Energy Technology Data Exchange (ETDEWEB)

    Weinmann, Amanda L.; Hruska, Carrie B.; Conners, Amy L.; O' Connor, Michael K. [Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, Minnesota 55905 (United States)

    2013-01-15

    Purpose: Molecular breast imaging (MBI) is a dedicated nuclear medicine breast imaging modality that employs dual-head cadmium zinc telluride (CZT) gamma cameras to functionally detect breast cancer. MBI has been shown to detect breast cancers otherwise occult on mammography and ultrasound. Currently, a MBI-guided biopsy system does not exist to biopsy such lesions. Our objective was to consider the utility of a novel conical slant-hole (CSH) collimator for rapid (<1 min) and accurate monitoring of lesion position to serve as part of a MBI-guided biopsy system. Methods: An initial CSH collimator design was derived from the dimensions of a parallel-hole collimator optimized for MBI performed with dual-head CZT gamma cameras. The parameters of the CSH collimator included the collimator height, cone slant angle, thickness of septa and cones of the collimator, and the annular areas exposed at the base of the cones. These parameters were varied within the geometric constraints of the MBI system to create several potential CSH collimator designs. The CSH collimator designs were evaluated using Monte Carlo simulations. The model included a breast compressed to a thickness of 6 cm with a 1-cm diameter lesion located 3 cm from the collimator face. The number of particles simulated was chosen to represent the count density of a low-dose, screening MBI study acquired with the parallel-hole collimator for 10 min after a {approx}150 MBq (4 mCi) injection of Tc-99m sestamibi. The same number of particles was used for the CSH collimator simulations. In the resulting simulated images, the count sensitivity, spatial resolution, and accuracy of the lesion depth determined from the lesion profile width were evaluated. Results: The CSH collimator design with default parameters derived from the optimal parallel-hole collimator provided 1-min images with error in the lesion depth estimation of 1.1 {+-} 0.7 mm and over 21 times the lesion count sensitivity relative to 1-min images

  6. Design and realisation of a microwave three-dimensional imaging system with application to breast-cancer detection

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Rubæk, T.; Krozer, V.; Meincke, P.

    2010-01-01

    An active microwave-imaging system for non-invasive detection of breast cancer based on dedicated hardware is described. Thirty-two transceiving channels are used to measure the amplitude and phase of the scattered fields in the three-dimensional (3D) imaging domain using electronic scanning. The 3...

  7. Predictive model for contrast-enhanced ultrasound of the breast: Is it feasible in malignant risk assessment of breast imaging reporting and data system 4 lesions?

    Science.gov (United States)

    Luo, Jun; Chen, Ji-Dong; Chen, Qing; Yue, Lin-Xian; Zhou, Guo; Lan, Cheng; Li, Yi; Wu, Chi-Hua; Lu, Jing-Qiao

    2016-01-01

    AIM: To build and evaluate predictive models for contrast-enhanced ultrasound (CEUS) of the breast to distinguish between benign and malignant lesions. METHODS: A total of 235 breast imaging reporting and data system (BI-RADS) 4 solid breast lesions were imaged via CEUS before core needle biopsy or surgical resection. CEUS results were analyzed on 10 enhancing patterns to evaluate diagnostic performance of three benign and three malignant CEUS models, with pathological results used as the gold standard. A logistic regression model was developed basing on the CEUS results, and then evaluated with receiver operating curve (ROC). RESULTS: Except in cases of enhanced homogeneity, the rest of the 9 enhancement appearances were statistically significant (P biopsy, and provide accurate BI-RADS classification. PMID:27358688

  8. Breast manifestations of systemic diseases

    Directory of Open Access Journals (Sweden)

    Dilaveri CA

    2012-02-01

    Full Text Available Christina A Dilaveri, Maire Brid Mac Bride, Nicole P Sandhu, Lonzetta Neal, Karthik Ghosh, Dietlind L Wahner-RoedlerDivision of General Internal Medicine, Mayo Clinic, Rochester, MN, USAAbstract: Although much emphasis has been placed on the primary presentations of breast cancer, little focus has been placed on how systemic illnesses may affect the breast. In this article, we discuss systemic illnesses that can manifest in the breast. We summarize the clinical features, imaging, histopathology, and treatment recommendations for endocrine, vascular, systemic inflammatory, infectious, and hematologic diseases, as well as for the extramammary malignancies that can present in the breast. Despite the rarity of these manifestations of systemic disease, knowledge of these conditions is critical to the appropriate evaluation and treatment of patients presenting with breast symptoms.Keywords: breast, endocrine, hematologic, infectious, vascular

  9. Molecular imaging of breast cancer

    NARCIS (Netherlands)

    Adams, A.L.L.

    2014-01-01

    Breast cancer is the most common type of cancer in women. Imaging techniques play a pivotal role in breast cancer management, especially in lesion detection, treatment planning and evaluation, and prognostication. These imaging techniques have however limitations such as the use of ionizing radiatio

  10. Imaging-Assisted Large-Format Breast Pathology: Program Rationale and Development in a Nonprofit Health System in the United States

    Directory of Open Access Journals (Sweden)

    F. Lee Tucker

    2012-01-01

    Full Text Available Modern breast imaging, including magnetic resonance imaging, provides an increasingly clear depiction of breast cancer extent, often with suboptimal pathologic confirmation. Pathologic findings guide management decisions, and small increments in reported tumor characteristics may rationalize significant changes in therapy and staging. Pathologic techniques to grossly examine resected breast tissue have changed little during this era of improved breast imaging and still rely primarily on the techniques of gross inspection and specimen palpation. Only limited imaging information is typically conveyed to pathologists, typically in the form of wire-localization images from breast-conserving procedures. Conventional techniques of specimen dissection and section submission destroy the three-dimensional integrity of the breast anatomy and tumor distribution. These traditional methods of breast specimen examination impose unnecessary limitations on correlation with imaging studies, measurement of cancer extent, multifocality, and margin distance. Improvements in pathologic diagnosis, reporting, and correlation of breast cancer characteristics can be achieved by integrating breast imagers into the specimen examination process and the use of large-format sections which preserve local anatomy. This paper describes the successful creation of a large-format pathology program to routinely serve all patients in a busy interdisciplinary breast center associated with a community-based nonprofit health system in the United States.

  11. Imaging breasts with silicone implants

    International Nuclear Information System (INIS)

    Over the last two decades, the use of breast implants both for breast augmentation and for breast reconstruction following mastectomy has increased substantially. It is estimated that around two million women have undergone breast augmentation, while hundreds of thousands have had breast reconstruction surgery. Different types of material have been used for breast implants, but silicone gel implants have been the dominating implant type. Many implants can lead to complications, such as hardening and rupture, and may therefore need in vivo evaluation by imaging, particularly if they lead to clinical symptoms. They can also pose problems in the assessment of surrounding breast tissue by conventional mammography. In this respect, imaging modalities such as ultrasound, computed tomography and magnetic resonance imaging offer greater possibilities to assess a failing implant, as well as surrounding breast tissue. Several factors, mainly of a psychological nature, lead to requests for breast implants. In this review article, only the imaging aspects of breasts with silicone gel implants will be dealt with. Each modality is concisely presented with its possibilities and limitations. (orig.)

  12. 3D Raman imaging of systemic endothelial dysfunction in the murine model of metastatic breast cancer.

    Science.gov (United States)

    Pacia, Marta Z; Buczek, Elzbieta; Blazejczyk, Agnieszka; Gregorius, Aleksandra; Wietrzyk, Joanna; Chlopicki, Stefan; Baranska, Malgorzata; Kaczor, Agnieszka

    2016-05-01

    It was recently reported in the murine model of metastatic breast cancer (4T1) that tumor progression and development of metastasis is associated with systemic endothelial dysfunction characterized by impaired nitric oxide (NO) production. Using Raman 3D confocal imaging with the analysis of the individual layers of the vascular wall combined with AFM endothelial surface imaging, we demonstrated that metastasis-induced systemic endothelial dysfunction resulted in distinct chemical changes in the endothelium of the aorta. These changes, manifested as a significant increase in the protein content (18 %) and a slight decrease in the lipid content (4 %), were limited to the endothelium and did not occur in the deeper layers of the vascular wall. The altered lipid to protein ratio in the endothelium, although more pronounced in the fixed vascular wall, was also observed in the freshly isolated unfixed vascular wall samples in the aqueous environment (12 and 7 % change of protein and lipid content, respectively). Our results support the finding that the metastasis induces systemic endothelial dysfunction that may contribute to cancer progression. Graphical Abstract Schematic illustration of methodology of sample preparation and measurement. PMID:26935932

  13. Impact of high energy resolution detectors on the performance of a PET system dedicated to breast cancer imaging.

    Science.gov (United States)

    Levin, Craig S; Foudray, Angela M K; Habte, Frezghi

    2006-01-01

    We are developing a high resolution, high sensitivity PET camera dedicated to breast cancer imaging. We are studying two novel detector technologies for this imaging system: a scintillation detector comprising layers of small lutetium oxyorthosilicate (LSO) crystals coupled to new position sensitive avalanche photodiodes (PSAPDs), and a pure semiconductor detector comprising cadmium zinc telluride (CZT) crystal slabs with thin anode and cathode strips deposited in orthogonal directions on either side of each slab. Both detectors achieve 1 mm spatial resolution with 3-5 mm directly measured photon interaction depth resolution, which promotes uniform reconstructed spatial resolution throughout a compact, breast-size field of view. Both detector types also achieve outstanding energy resolution (4 kcps for 200 microCi in a simulated breast phantom. PMID:17645990

  14. SU-E-J-134: An Augmented-Reality Optical Imaging System for Accurate Breast Positioning During Radiotherapy

    International Nuclear Information System (INIS)

    Purpose: Breast radiotherapy, particularly electronic compensation, may involve large dose gradients and difficult patient positioning problems. We have developed a simple self-calibrating augmented-reality system, which assists in accurately and reproducibly positioning the patient, by displaying her live image from a single camera superimposed on the correct perspective projection of her 3D CT data. Our method requires only a standard digital camera capable of live-view mode, installed in the treatment suite at an approximately-known orientation and position (rotation R; translation T). Methods: A 10-sphere calibration jig was constructed and CT imaged to provide a 3D model. The (R,T) relating the camera to the CT coordinate system were determined by acquiring a photograph of the jig and optimizing an objective function, which compares the true image points to points calculated with a given candidate R and T geometry. Using this geometric information, 3D CT patient data, viewed from the camera's perspective, is plotted using a Matlab routine. This image data is superimposed onto the real-time patient image, acquired by the camera, and displayed using standard live-view software. This enables the therapists to view both the patient's current and desired positions, and guide the patient into assuming the correct position. The method was evaluated using an in-house developed bolus-like breast phantom, mounted on a supporting platform, which could be tilted at various angles to simulate treatment-like geometries. Results: Our system allowed breast phantom alignment, with an accuracy of about 0.5 cm and 1 ± 0.5 degree. Better resolution could be possible using a camera with higher-zoom capabilities. Conclusion: We have developed an augmented-reality system, which combines a perspective projection of a CT image with a patient's real-time optical image. This system has the potential to improve patient setup accuracy during breast radiotherapy, and could possibly be

  15. Breast imaging reporting and data system (BI-RADS) lexicon for breast MRI: Interobserver variability in the description and assignment of BI-RADS category

    Energy Technology Data Exchange (ETDEWEB)

    El Khoury, Mona, E-mail: monelkhoury@gmail.com [Centre Hospitalier Universitaire de Montréal, Breast Centre, Radiology Department, 3840 Rue Saint Urbain, Montréal, QC H2W1T8 (Canada); Lalonde, Lucie; David, Julie; Labelle, Maude [Centre Hospitalier Universitaire de Montréal, Breast Centre, Radiology Department, 3840 Rue Saint Urbain, Montréal, QC H2W1T8 (Canada); Mesurolle, Benoit [Centre Hospitalier Universitaire de McGill, Cedar Breast Centre, Radiology Department, 687 Pine Avenue West, Montreal, QC H3A1A1 (Canada); Trop, Isabelle [Centre Hospitalier Universitaire de Montréal, Breast Centre, Radiology Department, 3840 Rue Saint Urbain, Montréal, QC H2W1T8 (Canada)

    2015-01-15

    Highlights: • The use of BI-RADS lexicon in interpreting breast MRI examinations is beneficial. • Our study shows: (a) moderate to substantial agreement between observers and (b) better agreement in interpreting mass than non-mass enhancement (NME). • Careful analysis of the NME should be done to help detect cancer as early as possible. - Abstract: Purpose: To retrospectively evaluate interobserver variability between breast radiologists when describing abnormal enhancement on breast MR examinations and assigning a BI-RADS category using the Breast Imaging Reporting and Data System (BI-RADS) terminology. Materials and methods: Five breast radiologists blinded to patients’ medical history and pathologic results retrospectively and independently reviewed 257 abnormal areas of enhancement on breast MRI performed in 173 women. Each radiologist described the focal enhancement using BI-RADS terminology and assigned a final BI-RADS category. Krippendorff's α coefficient of agreement was used to asses interobserver variability. Results: All radiologists agreed on the morphology of enhancement in 183/257 (71%) lesions, yielding a substantial agreement (Krippendorff's α = 0.71). Moderate agreement was obtained for mass descriptors – shape, margins and internal enhancement – (α = 0.55, 0.51 and 0.45 respectively) and NME (non-mass enhancement) descriptors – distribution and internal enhancement – (α = 0.54 and 0.43). Overall substantial agreement was obtained for BI-RADS category assignment (α = 0.71). It was however only moderate (α = 0.38) for NME compared to mass (α = 0.80). Conclusion: Our study shows good agreement in describing mass and NME on a breast MR examination but a better agreement in predicting malignancy for mass than NME.

  16. Computerized Ultrasound Risk Evaluation (CURE) System: Development of Combined Transmission and Reflection Ultrasound with New Reconstruction Algorithms for Breast Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Littrup, P J; Duric, N; Azevedo, S; Chambers, D; Candy, J V; Johnson, S; Auner, G; Rather, J; Holsapple, E T

    2001-09-07

    Our Computerized Ultrasound Risk Evaluation (CURE) system has been developed to the engineering prototype stage and generated unique data sets of both transmission and reflection ultrasound (US). This paper will help define the clinical underpinnings of the developmental process and interpret the imaging results from a similar perspective. The CURE project was designed to incorporate numerous diagnostic parameters to improve upon two major areas of early breast cancer detection. CURE may provide improved tissue characterization of breast masses and reliable detection of abnormal microcalcifications found in some breast cancers and ductal carcinoma in situ (DCIS). Current breast US is limited to mass evaluation, whereas mammography also detects and guides biopsy of malignant calcifications. Screening with CURE remains a distant goal, but improved follow-up of mammographic abnormalities may represent a feasible breakthrough. Improved tissue characterization could result in reduction of the estimated one million benign biopsies each year in the United States, costing up to several billion dollars. Most breast calcifications are benign and comprise-80% of stereotactic biopsies guided by mammography. Ultrasound has the capability of finding some groups of calcifications, but further improvements in resolution should also address tissue characterization to define the soft tissue filling of ducts by DCIS. In this manner, CURE may be able to more accurately identify the malignant calcifications associated with progression of DCIS or early cancers. Currently, high-resolution US images of the breast are performed in the reflection mode at higher frequencies, which also limits depth of penetration. Reconstruction of reflection ultrasound images relies upon acoustic impedance differences in the tissue and includes only direct backscatter of the ultrasound signal. Resolution and tissue contrast of current US continues to improve with denser transducer arrays and image

  17. How to improve your breast cancer program: Standardized reporting using the new American College of Radiology Breast Imaging-Reporting and Data System

    International Nuclear Information System (INIS)

    In the USA, the use of the American College of Radiology Breast Imaging-Reporting and Data System (ACR BI-RADS) has served not only as a quality assurance tool and guide to standardizing breast imaging reports but has also improved communication between referring physicians, researchers, and patients. In fact, in the USA, the Mammography Quality Standards Act of 1997 requires that all mammograms be assigned a BI-RADS category based on the finding of most concern. In this manuscript, we aim to review the recommendations provided in the 4th edition of the ACR BI-RADS for mammography, USG, and MRI. We also review the major controversies surrounding the use of ACR BI-RADS

  18. Clinical Report on the First Prototype of a Photoacoustic Tomography System with Dual Illumination for Breast Cancer Imaging.

    Directory of Open Access Journals (Sweden)

    Elham Fakhrejahani

    Full Text Available Photoacoustic tomography is a recently developed imaging modality that can provide high spatial-resolution images of hemoglobin distribution in tissues such as the breast. Because breast cancer is an angiogenesis-dependent type of malignancy, we evaluated the clinical acceptability of breast tissue images produced using our first prototype photoacoustic mammography (PAM system in patients with known cancer. Post-excisionally, histological sections of the tumors were stained immunohistochemically (IHC for CD31 (an endothelial marker and carbonic anhydrase IX (CAIX (a marker of hypoxia. Whole-slide scanning and image analyses were used to evaluate the tumor microvessel distribution pattern and to calculate the total vascular perimeter (TVP/area for each lesion. In this clinical study, 42 lesions were primarily scanned using PAM preoperatively, three of which were reported to be benign and were excluded from statistical analysis. Images were produced for 29 out of 39 cancers (visibility rate = 74.4% at the median depth of 26.5 (3.25-51.2 mm. Age, menopausal status, body mass index, history of neoadjuvant treatment, clinical stage and histological tumor angiogenesis markers did not seem to affect the visibility. The oxygen saturation level in all of the measured lesions was lower than in the subcutaneous counterpart vessels (Wilcoxon test, p value<0.001, as well as in the counterpart contralateral normal breast region of interest (ROI (Wilcoxon test, p value = 0.001. Although the oxygen saturation level was not statistically significant between CAIX-positive vs. -negative cases, lesional TVP/area showed a positive correlation with the oxygen saturation level only in the group that had received therapy before PAM. In conclusion, the vascular and oxygenation data obtained by PAM have great potential for identifying functional features of breast tumors.

  19. The application of surgical navigation system using optical molecular imaging technology in orthotopic breast cancer and metastasis studies

    Science.gov (United States)

    Chi, Chongwei; Zhang, Qian; Kou, Deqiang; Ye, Jinzuo; Mao, Yamin; Qiu, Jingdan; Wang, Jiandong; Yang, Xin; Du, Yang; Tian, Jie

    2014-02-01

    Currently, it has been an international focus on intraoperative precise positioning and accurate resection of tumor and metastases. The methods such as X-rays, computed tomography (CT), magnetic resonance imaging (MRI) and positron emission tomography (PET) have played an important role in preoperative accurate diagnosis. However, most of them are inapplicable for intraoperative surgery. We have proposed a surgical navigation system based on optical molecular imaging technology for intraoperative detection of tumors and metastasis. This system collects images from two CCD cameras for real-time fluorescent and color imaging. For image processing, the template matching algorithm is used for multispectral image fusion. For the application of tumor detection, the mouse breast cancer cell line 4T1-luc, which shows highly metastasis, was used for tumor model establishment and a model of matrix metalloproteinase (MMP) expressing breast cancer. The tumor-bearing nude mice were given tail vein injection of MMP 750FAST (PerkinElmer, Inc. USA) probe and imaged with both bioluminescence and fluorescence to assess in vivo binding of the probe to the tumor and metastases sites. Hematoxylin and eosin (H&E) staining was performed to confirm the presence of tumor and metastasis. As a result, one tumor can be observed visually in vivo. However liver metastasis has been detected under surgical navigation system and all were confirmed by histology. This approach helps surgeons to find orthotopic tumors and metastasis during intraoperative resection and visualize tumor borders for precise positioning. Further investigation is needed for future application in clinics.

  20. Molecular breast imaging. An update

    International Nuclear Information System (INIS)

    The aim of molecular imaging is to visualize and quantify biological, physiological and pathological processes at cellular and molecular levels. Molecular imaging using various techniques has recently become established in breast imaging. Currently molecular imaging techniques comprise multiparametric magnetic resonance imaging (MRI) using dynamic contrast-enhanced MRI (DCE-MRI), diffusion-weighted imaging (DWI), proton MR spectroscopy (1H-MRSI), nuclear imaging by breast-specific gamma imaging (BSGI), positron emission tomography (PET) and positron emission mammography (PEM) and combinations of techniques (e.g. PET-CT and multiparametric PET-MRI). Recently, novel techniques for molecular imaging of breast tumors, such as sodium imaging (23Na-MRI), phosphorus spectroscopy (31P-MRSI) and hyperpolarized MRI as well as specific radiotracers have been developed and are currently under investigation. It can be expected that molecular imaging of breast tumors will enable a simultaneous assessment of the multiple metabolic and molecular processes involved in cancer development and thus an improved detection, characterization, staging and monitoring of response to treatment will become possible. (orig.)

  1. SU-E-J-134: An Augmented-Reality Optical Imaging System for Accurate Breast Positioning During Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Nazareth, D; Malhotra, H; French, S [Roswell Park Cancer Institute, Buffalo, NY (United States); Hoffmann, K [Neurosurgery at SUNY at Buffalo, Buffalo, NY (United States); Merrow, C [Bassett Healthcare, Oneonta, NY (United States)

    2014-06-01

    Purpose: Breast radiotherapy, particularly electronic compensation, may involve large dose gradients and difficult patient positioning problems. We have developed a simple self-calibrating augmented-reality system, which assists in accurately and reproducibly positioning the patient, by displaying her live image from a single camera superimposed on the correct perspective projection of her 3D CT data. Our method requires only a standard digital camera capable of live-view mode, installed in the treatment suite at an approximately-known orientation and position (rotation R; translation T). Methods: A 10-sphere calibration jig was constructed and CT imaged to provide a 3D model. The (R,T) relating the camera to the CT coordinate system were determined by acquiring a photograph of the jig and optimizing an objective function, which compares the true image points to points calculated with a given candidate R and T geometry. Using this geometric information, 3D CT patient data, viewed from the camera's perspective, is plotted using a Matlab routine. This image data is superimposed onto the real-time patient image, acquired by the camera, and displayed using standard live-view software. This enables the therapists to view both the patient's current and desired positions, and guide the patient into assuming the correct position. The method was evaluated using an in-house developed bolus-like breast phantom, mounted on a supporting platform, which could be tilted at various angles to simulate treatment-like geometries. Results: Our system allowed breast phantom alignment, with an accuracy of about 0.5 cm and 1 ± 0.5 degree. Better resolution could be possible using a camera with higher-zoom capabilities. Conclusion: We have developed an augmented-reality system, which combines a perspective projection of a CT image with a patient's real-time optical image. This system has the potential to improve patient setup accuracy during breast radiotherapy, and could

  2. Sentinel lymph node detection in breast cancer patients using surgical navigation system based on fluorescence molecular imaging technology

    Science.gov (United States)

    Chi, Chongwei; Kou, Deqiang; Ye, Jinzuo; Mao, Yamin; Qiu, Jingdan; Wang, Jiandong; Yang, Xin; Tian, Jie

    2015-03-01

    Introduction: Precision and personalization treatments are expected to be effective methods for early stage cancer studies. Breast cancer is a major threat to women's health and sentinel lymph node biopsy (SLNB) is an effective method to realize precision and personalized treatment for axillary lymph node (ALN) negative patients. In this study, we developed a surgical navigation system (SNS) based on optical molecular imaging technology for the precise detection of the sentinel lymph node (SLN) in breast cancer patients. This approach helps surgeons in precise positioning during surgery. Methods: The SNS was mainly based on the technology of optical molecular imaging. A novel optical path has been designed in our hardware system and a feature-matching algorithm has been devised to achieve rapid fluorescence and color image registration fusion. Ten in vivo studies of SLN detection in rabbits using indocyanine green (ICG) and blue dye were executed for system evaluation and 8 breast cancer patients accepted the combination method for therapy. Results: The detection rate of the combination method was 100% and an average of 2.6 SLNs was found in all patients. Our results showed that the method of using SNS to detect SLN has the potential to promote its application. Conclusion: The advantage of this system is the real-time tracing of lymph flow in a one-step procedure. The results demonstrated the feasibility of the system for providing accurate location and reliable treatment for surgeons. Our approach delivers valuable information and facilitates more detailed exploration for image-guided surgery research.

  3. Molecular Breast Imaging Using Emission Tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Gopan, O. [University of Florida; Gilland, D. [University of Florida; Weisenberger, Andrew G. [JLAB; Kross, Brian J. [JLAB; Welch, Benjamin L. [Dilon Technologies

    2013-06-01

    Purpose: Tour objective is to design a novel SPECT system for molecular breast imaging (MBI) and evaluate its performance. The limited angle SPECT system, or emission tomosynthesis, is designed to achieve 3D images of the breast with high spatial resolution/sensitivity. The system uses a simplified detector motion and is conducive to on-board biopsy and mult-modal imaging with mammography. Methods: The novel feature of the proposed gamma camera is a variable-angle, slant-hole (VASH) collimator, which is well suited for limited angle SPECT of a mildly compressed breast. The collimator holes change slant angle while the camera surface remains flush against the compression paddle. This allows the camera to vary the angular view ({+-}30{degrees}, {+-}45{degrees}) for tomographic imaging while keeping the camera close to the object for high spatial resolution and/or sensitivity. Theoretical analysis and Monte Carlo simulations were performed assuming a point source and isolated breast phantom. Spatial resolution, sensitivity, contrast and SNR were measured. Results were compared to single-view, planar images and conventional SPECT. For both conventional SPECT and VASH, data were reconstructed using iterative algorithms. Finally, a proof-of-concept VASH collimator was constructed for experimental evaluation. Results: Measured spatial resolution/sensitivity with VASH showed good agreement with theory including depth-of-interaction (DOI) effects. The DOI effect diminished the depth resolution by approximately 2 mm. Increasing the slant angle range from {+-}30{degrees} to {+-}45{degrees} resulted in an approximately 1 mm improvement in the depth resolution. In the breast phantom images, VASH showed improved contrast and SNR over conventional SPECT and improved contrast over planar scintimmammography. Reconstructed images from the proof-of-concept VASH collimator demonstrated reasonable depth resolution capabilities using limited angle projection data. Conclusion: We

  4. The Breast Imaging Reporting and Data System (BI-RADS) in the Dutch breast cancer screening programme: its role as an assessment and stratification tool

    International Nuclear Information System (INIS)

    To assess the suitability of the Breast Imaging Reporting and Data System (BI-RADS) as a quality assessment tool in the Dutch breast cancer screening programme. The data of 93,793 screened women in the Amsterdam screening region (November 2005-July 2006) were reviewed. BI-RADS categories, work-up, age, final diagnosis and final TNM classification were available from the screening registry. Interval cancers were obtained through linkage with the cancer registry. BI-RADS was introduced as a pilot in the Amsterdam region before the nationwide introduction of digital mammography (2009-2010). A total of 1,559 women were referred to hospital (referral rate 1.7 %). Breast cancer was diagnosed in 485 women (detection rate 0.52 %); 253 interval cancers were reported, yielding a programme sensitivity of 66 % and specificity of 99 %. BI-RADS 0 had a lower positive predictive value (PPV, 14.1 %) than BI-RADS 4 (39.1 %) and BI-RADS 5 (92.9 %; P < 0.0001). The number of invasive procedures and tumour size also differed significantly between BI-RADS categories (P < 0.0001). The significant differences in PPV, invasive procedures and tumour size match with stratification into BI-RADS categories. It revealed inter-observer variability between screening radiologists and can thus be used as a quality assessment tool in screening and as a stratification tool in diagnostic work-up. (orig.)

  5. Performance evaluation of breast image compression techniques

    International Nuclear Information System (INIS)

    Novel diagnosis orienting tele working systems manipulate, store, and process medical data through real time communication - conferencing schemes. One of the most important factors affecting the performance of these systems is image handling. Compression algorithms can be applied to the medical images, in order to minimize : a) the volume of data to be stored in the database, b) the demanded bandwidth from the network, c) the transmission costs, and to minimize the speed of the transmitted data. In this paper an estimation of all the factors of the process that affect the presentation of breast images is made, from the time the images are produced from a modality, till the compressed images are stored, or transmitted in a Broadband network (e.g. B-ISDN). The images used were scanned images of the TOR(MAX) Leeds breast phantom, as well as typical breast images. A comparison of seven compression techniques has been done, based on objective criteria such as Mean Square Error (MSE), resolution, contrast, etc. The user can choose the appropriate compression ratio in order to achieve the desired image quality. (authors)

  6. Projection Based Region of Interest Segmentation in Breast MRI Images

    Directory of Open Access Journals (Sweden)

    Sim Kok Swee

    2011-01-01

    Full Text Available In this paper, a computer aided design auto breast region segmentation system is presented to identify the region of interest (ROI in magnetic resonance imaging (MRI images. The system is proposed due to the necessary for performing useful postprocessing on the image for breast cancer research and treatment.  Besides, while the ROI is segmented, the image post-processing efficiency of the system is greatly improved.  The vertical and horizontal projections algorithms are employed to refine the breast ROI. The methodology has been applied on 55 sets of Digital Image and Communications in Medicine (DICOM breast MRI datasets images. The experimental results show that the system is able to segment the breast ROI accurately.

  7. Breast MRI: guidelines from the European Society of Breast Imaging

    International Nuclear Information System (INIS)

    The aim of breast MRI is to obtain a reliable evaluation of any lesion within the breast. It is currently always used as an adjunct to the standard diagnostic procedures of the breast, i.e., clinical examination, mammography and ultrasound. Whereas the sensitivity of breast MRI is usually very high, specificity - as in all breast imaging modalities - depends on many factors such as reader expertise, use of adequate techniques and composition of the patient cohorts. Since breast MRI will always yield MR-only visible questionable lesions that require an MR-guided intervention for clarification, MRI should only be offered by institutions that can also offer a MRI-guided breast biopsy or that are in close contact with a site that can perform this type of biopsy for them. Radiologists involved in breast imaging should ensure that they have a thorough knowledge of the MRI techniques that are necessary for breast imaging, that they know how to evaluate a breast MRI using the ACR BI-RADS MRI lexicon, and most important, when to perform breast MRI. This manuscript provides guidelines on the current best practice for the use of breast MRI, and the methods to be used, from the European Society of Breast Imaging (EUSOBI). (orig.)

  8. A Quantitative Diffuse Reflectance Imaging (QDRI System for Comprehensive Surveillance of the Morphological Landscape in Breast Tumor Margins.

    Directory of Open Access Journals (Sweden)

    Brandon S Nichols

    Full Text Available In an ongoing effort to address the clear clinical unmet needs surrounding breast conserving surgery (BCS, our group has developed a next-generation multiplexed optical-fiber-based tool to assess breast tumor margin status during initial surgeries. Specifically detailed in this work is the performance and clinical validation of a research-grade intra-operative tool for margin assessment based on diffuse optical spectroscopy. Previous work published by our group has illustrated the proof-of-concept generations of this device; here we incorporate a highly optimized quantitative diffuse reflectance imaging (QDRI system utilizing a wide-field (imaging area = 17 cm(2 49-channel multiplexed fiber optic probe, a custom raster-scanning imaging platform, a custom dual-channel white LED source, and an astronomy grade imaging CCD and spectrograph. The system signal to noise ratio (SNR was found to be greater than 40 dB for all channels. Optical property estimation error was found to be less than 10%, on average, over a wide range of absorption (μa = 0-8.9 cm(-1 and scattering (μs' = 7.0-9.7 cm(-1 coefficients. Very low inter-channel and CCD crosstalk was observed (2% max when used on turbid media (including breast tissue. A raster-scanning mechanism was developed to achieve sub-pixel resolution and was found to be optimally performed at an upsample factor of 8, affording 0.75 mm spatially resolved diffuse reflectance images (λ = 450-600 nm of an entire margin (area = 17 cm(2 in 13.8 minutes (1.23 cm(2/min. Moreover, controlled pressure application at the probe-tissue interface afforded by the imaging platform reduces repeated scan variability, providing <1% variation across repeated scans of clinical specimens. We demonstrate the clinical utility of this device through a pilot 20-patient study of high-resolution optical parameter maps of the ratio of the β-carotene concentration to the reduced scattering coefficient. An empirical cumulative

  9. TU-A-17A-02: In Memoriam of Ben Galkin: Virtual Tools for Validation of X-Ray Breast Imaging Systems

    International Nuclear Information System (INIS)

    This symposium will explore simulation methods for the preclinical evaluation of novel 3D and 4D x-ray breast imaging systems – the subject of AAPM taskgroup TG234. Given the complex design of modern imaging systems, simulations offer significant advantages over long and costly clinical studies in terms of reproducibility, reduced radiation exposures, a known reference standard, and the capability for studying patient and disease subpopulations through appropriate choice of simulation parameters. Our focus will be on testing the realism of software anthropomorphic phantoms and virtual clinical trials tools developed for the optimization and validation of breast imaging systems. The symposium will review the stateof- the-science, as well as the advantages and limitations of various approaches to testing realism of phantoms and simulated breast images. Approaches based upon the visual assessment of synthetic breast images by expert observers will be contrasted with approaches based upon comparing statistical properties between synthetic and clinical images. The role of observer models in the assessment of realism will be considered. Finally, an industry perspective will be presented, summarizing the role and importance of virtual tools and simulation methods in product development. The challenges and conditions that must be satisfied in order for computational modeling and simulation to play a significantly increased role in the design and evaluation of novel breast imaging systems will be addressed. Learning Objectives: Review the state-of-the science in testing realism of software anthropomorphic phantoms and virtual clinical trials tools; Compare approaches based upon the visual assessment by expert observers vs. the analysis of statistical properties of synthetic images; Discuss the role of observer models in the assessment of realism; Summarize the industry perspective to virtual methods for breast imaging

  10. Anatomic Breast Coordinate System for Mammogram Analysis

    DEFF Research Database (Denmark)

    Karemore, Gopal Raghunath; Brandt, S; Karssemeijer, N;

    2011-01-01

    represented by geodesic distance (s) from nipple and parametric angle (¿) as shown in figure 1. The scoring technique called MTR (mammographic texture resemblance marker) used this breast coordinate system to extract Gaussian derivative features. The features extracted using the (x,y) and the curve...... alignment error. Potentially this coordinate system may be used also for improving precision in CAD systems. Keywords: Breast Coordinate system, Breast Cancer, Imaging marker.......Purpose Many researchers have investigated measures also other than density in the mammogram such as measures based on texture to improve breast cancer risk assessment. However, parenchymal texture characteristics are highly dependent on the orientation of vasculature structure and fibrous tissue...

  11. Multispectral breast imaging using a ten-wavelength, 64x64 source/detector channels silicon photodiode-based diffuse optical tomography system

    International Nuclear Information System (INIS)

    We describe a compact diffuse optical tomography system specifically designed for breast imaging. The system consists of 64 silicon photodiode detectors, 64 excitation points, and 10 diode lasers in the near-infrared region, allowing multispectral, three-dimensional optical imaging of breast tissue. We also detail the system performance and optimization through a calibration procedure. The system is evaluated using tissue-like phantom experiments and an in vivo clinic experiment. Quantitative two-dimensional (2D) and three-dimensional (3D) images of absorption and reduced scattering coefficients are obtained from these experiments. The ten-wavelength spectra of the extracted reduced scattering coefficient enable quantitative morphological images to be reconstructed with this system. From the in vivo clinic experiment, functional images including deoxyhemoglobin, oxyhemoglobin, and water concentration are recovered and tumors are detected with correct size and position compared with the mammography

  12. Validity of the breast imaging reporting and data system BI-RADS{sup TM} for clinical mammography in men; Anwendbarkeit des Breast Imaging Reporting and Data System (BI-RADS{sup TM}) auf die klinische Mammographie des Mannes

    Energy Technology Data Exchange (ETDEWEB)

    Bock, K.; Duda, V.F.; Bonwetsch, C.; Hadji, P.; Schulz, K.D. [Marburg Univ. (Germany). Klinik fuer Gynaekologie, Gynaekologische Endokrinologie und Onkologie; Iwinska-Zelder, J.; Klose, K.J. [Marburg Univ. (Germany). Klinik fuer Diagnostische Radiologie; Rode, G. [Diagnostische Gemeinschaftspraxis Marburg (Germany)

    2001-11-01

    Aim: The implementation of diagnostic standards enhances quality assurance. The American College of Radiology's breast imaging-reporting and data system (BI-RADS{sup TM}) is intended to standardize terminology in the mammography report, the assessment of the findings, and the recommendation af action to be taken. The purpose of this study was to assess the value of the standardized system for clinically apparent male breast tumors. Do the special male anatomy and physiology limit the applicability of an evaluation system designed for female screening mammograms? Methods: 4 investigators with different degrees of experience retrospectively evaluated 160 male mammograms. Our study was based on the 36 cases which could be correlated to histopathological findings: gynecomastia in the majority of cases, but also 4 invasive ductal carcinoma, 1 leiomyosarcoma and 1 ductal carcinoma in situ. Results: Assessment of the mammograms by BI-RADS{sup TM} (3{sup rd} Edition 1998) correctly placed all cases of malignancy into categories 4 and 5 without respect to the investigators's level of experience. Conclusion: Therefore, we conclude that the BI-RADS{sup TM}-classification can successfully be used to classify male mammograms with a high positive predictive value for malignancy. Knowledge of gender-specific imaging characteristics increases the specificity at a constant high level of sensitivity. (orig.) [German] Ziel: In der apparativen Diagnostik dient die Einfuehrung von Standards der Qualitaetssicherung. Das breast imaging-reporting and data system (BI-RADS{sup TM}) des American College of Radiology standardisiert den Sprachgebrauch in der Befundbeschreibung, die Befundbewertung und die resultierenden Empfehlungen in der Mammographie. Unser Interesse galt der Frage, inwieweit dieses System der Kategorisierung von Screening-Mammographien der Frau uebertragbar ist auf klinische Mammographien des Mannes. Begrenzen Anatomie und Physiologie der maennlichen Brustdruese

  13. Assessment and Development of Microwave Imaging for Breast Cancer Detection

    DEFF Research Database (Denmark)

    Jensen, Peter Damsgaard

    . However, a number of different challenges arise when using data from multiple frequencies for imaging of biological targets. The performance of a nonlinear microwave tomography algorithm is tested using simulated data from anatomically realistic breast phantoms. These tests include several different......At the Technical University of Denmark (DTU), a 3D tomographic microwave imaging system is currently being developed with the aim of using nonlinear microwave imaging for breast-cancer detection. The imaging algorithm used in the system is based on an iterative Newton-type scheme. In this algorithm...... algorithm used in the microwave tomographic imaging system is presented. Non-linear microwave tomographic imaging of the breast is a challenging computational problem. The breast is heterogeneous and contains several high-contrast and lossy regions, resulting in large differences in the measured signal...

  14. Breast Imaging after Breast Augmentation with Autologous Tissues

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Kyu Won; Seo, Bo Kyung; Shim, Eddeum; Song, Sung Eun; Cho, Kyu Ran [Dept. of Radiology, Korea University Anam Hospital, Seoul (Korea, Republic of); Yoon, Eul Sik [Korea University Ansan Hospital, Ansan (Korea, Republic of); Woo, Ok Hee [Dept. of Radiology, Korea University Guro Hospital, Seoul (Korea, Republic of)

    2012-06-15

    The use of autologous tissue transfer for breast augmentation is an alternative to using foreign implant materials. The benefits of this method are the removal of unwanted fat from other body parts, no risk of implant rupture, and the same feel as real breast tissue. However, sometimes there is a dilemma about whether or not to biopsy for calcifications or masses detected after the procedure is completed. The purpose of this study is to illustrate the procedures of breast augmentation with autologous tissues, the imaging features of various complications, and the role of imaging in the diagnosis and management of complications and hidden breast diseases.

  15. Breast Imaging after Breast Augmentation with Autologous Tissues

    International Nuclear Information System (INIS)

    The use of autologous tissue transfer for breast augmentation is an alternative to using foreign implant materials. The benefits of this method are the removal of unwanted fat from other body parts, no risk of implant rupture, and the same feel as real breast tissue. However, sometimes there is a dilemma about whether or not to biopsy for calcifications or masses detected after the procedure is completed. The purpose of this study is to illustrate the procedures of breast augmentation with autologous tissues, the imaging features of various complications, and the role of imaging in the diagnosis and management of complications and hidden breast diseases.

  16. Computerized detection of breast cancer on automated breast ultrasound imaging of women with dense breasts

    Energy Technology Data Exchange (ETDEWEB)

    Drukker, Karen, E-mail: kdrukker@uchicago.edu; Sennett, Charlene A.; Giger, Maryellen L. [Department of Radiology, MC2026, The University of Chicago, 5841 South Maryland Avenue, Chicago, Illinois 60637 (United States)

    2014-01-15

    Purpose: Develop a computer-aided detection method and investigate its feasibility for detection of breast cancer in automated 3D ultrasound images of women with dense breasts. Methods: The HIPAA compliant study involved a dataset of volumetric ultrasound image data, “views,” acquired with an automated U-Systems Somo•V{sup ®} ABUS system for 185 asymptomatic women with dense breasts (BI-RADS Composition/Density 3 or 4). For each patient, three whole-breast views (3D image volumes) per breast were acquired. A total of 52 patients had breast cancer (61 cancers), diagnosed through any follow-up at most 365 days after the original screening mammogram. Thirty-one of these patients (32 cancers) had a screening-mammogram with a clinically assigned BI-RADS Assessment Category 1 or 2, i.e., were mammographically negative. All software used for analysis was developed in-house and involved 3 steps: (1) detection of initial tumor candidates, (2) characterization of candidates, and (3) elimination of false-positive candidates. Performance was assessed by calculating the cancer detection sensitivity as a function of the number of “marks” (detections) per view. Results: At a single mark per view, i.e., six marks per patient, the median detection sensitivity by cancer was 50.0% (16/32) ± 6% for patients with a screening mammogram-assigned BI-RADS category 1 or 2—similar to radiologists’ performance sensitivity (49.9%) for this dataset from a prior reader study—and 45.9% (28/61) ± 4% for all patients. Conclusions: Promising detection sensitivity was obtained for the computer on a 3D ultrasound dataset of women with dense breasts at a rate of false-positive detections that may be acceptable for clinical implementation.

  17. Clinical usefulness of breast-specific gamma imaging as an adjunct modality to mammography for diagnosis of breast cancer: a systemic review and meta-analysis

    International Nuclear Information System (INIS)

    The purpose of this study was to assess the diagnostic performance of breast-specific gamma imaging (BSGI) as an adjunct modality to mammography for detecting breast cancer. Comprehensive searches of MEDLINE (1984 to August 2012) and EMBASE (1994 to August 2012) were performed. A summary receiver operating characteristic curve (SROC) was constructed to summarize the overall test performance of BSGI. The sensitivities for detecting subcentimetre cancer and ductal carcinoma in situ (DCIS) were pooled. The potential of BSGI to complement mammography was also evaluated by identifying mammography-occult breast cancer. Analysis of the studies revealed that the overall validity estimates of BSGI in detecting breast cancer were as follows: sensitivity 95 % (95 % CI 93-96 %), specificity 80 % (95 % CI 78-82 %), positive likelihood ratio 4.63 (95 % CI 3.13-6.85), negative likelihood ratio 0.08 (95 % CI 0.05-0.14), and diagnostic odds ratio 56.67 (95 % CI 26.68-120.34). The area under the SROC was 0.9552 and the Q* point was 0.8977. The pooled sensitivities for detecting subcentimetre cancer and DCIS were 84 % (95 % CI 80-88 %) and 88 % (95 % CI 81-92 %), respectively. Among patients with normal mammography, 4 % were diagnosed with breast cancer by BSGI, and among those with mammography suggestive of malignancy or new biopsy-proven breast cancer, 6 % were diagnosed with additional cancers in the breast by BSGI. BSGI had a high diagnostic performance as an excellent adjunct modality to mammography for detecting breast cancer. The ability to identify subcentimetre cancer and DCIS was also high. (orig.)

  18. Clinical usefulness of breast-specific gamma imaging as an adjunct modality to mammography for diagnosis of breast cancer: a systemic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yu.; Wei, Wei; Yang, Hua-Wei; Liu, Jian-Lun [Affiliated Cancer Hospital of Guangxi Medical University, Department of Breast Surgery of Guangxi Cancer Hospital, Nanning, Guangxi (China)

    2013-03-15

    The purpose of this study was to assess the diagnostic performance of breast-specific gamma imaging (BSGI) as an adjunct modality to mammography for detecting breast cancer. Comprehensive searches of MEDLINE (1984 to August 2012) and EMBASE (1994 to August 2012) were performed. A summary receiver operating characteristic curve (SROC) was constructed to summarize the overall test performance of BSGI. The sensitivities for detecting subcentimetre cancer and ductal carcinoma in situ (DCIS) were pooled. The potential of BSGI to complement mammography was also evaluated by identifying mammography-occult breast cancer. Analysis of the studies revealed that the overall validity estimates of BSGI in detecting breast cancer were as follows: sensitivity 95 % (95 % CI 93-96 %), specificity 80 % (95 % CI 78-82 %), positive likelihood ratio 4.63 (95 % CI 3.13-6.85), negative likelihood ratio 0.08 (95 % CI 0.05-0.14), and diagnostic odds ratio 56.67 (95 % CI 26.68-120.34). The area under the SROC was 0.9552 and the Q* point was 0.8977. The pooled sensitivities for detecting subcentimetre cancer and DCIS were 84 % (95 % CI 80-88 %) and 88 % (95 % CI 81-92 %), respectively. Among patients with normal mammography, 4 % were diagnosed with breast cancer by BSGI, and among those with mammography suggestive of malignancy or new biopsy-proven breast cancer, 6 % were diagnosed with additional cancers in the breast by BSGI. BSGI had a high diagnostic performance as an excellent adjunct modality to mammography for detecting breast cancer. The ability to identify subcentimetre cancer and DCIS was also high. (orig.)

  19. Breast cancer imaging by microwave-induced thermoacoustic tomography

    Science.gov (United States)

    Xu, Minghua; Ku, Geng; Jin, Xing; Wang, Lihong V.; Fornage, Bruno D.; Hunt, Kelly K.

    2005-04-01

    We report a preliminary study of breast cancer imaging by microwave-induced thermoacoustic tomography. In this study, we built a prototype of breast cancer imager based on a circular scan mode. A 3-GHz 0.3~0.5-μs microwave is used as the excitation energy source. A 2.25-MHz ultrasound transducer scans the thermoacoustic signals. All the measured data is transferred to a personal computer for imaging based on our proposed back-projection reconstruction algorithms. We quantified the line spread function of the imaging system. It shows the spatial resolution of our experimental system reaches 0.5 mm. After phantom experiments demonstrated the principle of this technique, we moved the imaging system to the University of Texas MD Anderson Cancer Center to image the excised breast cancer specimens. After the surgery performed by the physicians at the Cancer Center, the excised breast specimen was placed in a plastic cylindrical container with a diameter of 10 cm; and it was then imaged by three imaging modalities: radiograph, ultrasound and thermoacoustic imaging. Four excised breast specimens have been tested. The tumor regions have been clearly located. This preliminary study demonstrated the potential of microwave-induced thermoacoustic tomography for applications in breast cancer imaging.

  20. Experimental and Other Breast Imaging Methods

    Science.gov (United States)

    ... Home Learn About Cancer Stay Healthy Find Support & Treatment Explore Research Get Involved Find Local ACS Stay Healthy » Find Cancer Early » Exam and Test Descriptions » Mammograms and Other Breast Imaging Procedures » Experimental breast imaging tests Share this Page Close Push ...

  1. A review of biomechanically informed breast image registration

    Science.gov (United States)

    Hipwell, John H.; Vavourakis, Vasileios; Han, Lianghao; Mertzanidou, Thomy; Eiben, Björn; Hawkes, David J.

    2016-01-01

    Breast radiology encompasses the full range of imaging modalities from routine imaging via x-ray mammography, magnetic resonance imaging and ultrasound (both two- and three-dimensional), to more recent technologies such as digital breast tomosynthesis, and dedicated breast imaging systems for positron emission mammography and ultrasound tomography. In addition new and experimental modalities, such as Photoacoustics, Near Infrared Spectroscopy and Electrical Impedance Tomography etc, are emerging. The breast is a highly deformable structure however, and this greatly complicates visual comparison of imaging modalities for the purposes of breast screening, cancer diagnosis (including image guided biopsy), tumour staging, treatment monitoring, surgical planning and simulation of the effects of surgery and wound healing etc. Due primarily to the challenges posed by these gross, non-rigid deformations, development of automated methods which enable registration, and hence fusion, of information within and across breast imaging modalities, and between the images and the physical space of the breast during interventions, remains an active research field which has yet to translate suitable methods into clinical practice. This review describes current research in the field of breast biomechanical modelling and identifies relevant publications where the resulting models have been incorporated into breast image registration and simulation algorithms. Despite these developments there remain a number of issues that limit clinical application of biomechanical modelling. These include the accuracy of constitutive modelling, implementation of representative boundary conditions, failure to meet clinically acceptable levels of computational cost, challenges associated with automating patient-specific model generation (i.e. robust image segmentation and mesh generation) and the complexity of applying biomechanical modelling methods in routine clinical practice.

  2. Imaging Lymphatic System in Breast Cancer Patients with Magnetic Resonance Lymphangiography

    OpenAIRE

    Lu, Qing; Hua, Jia; Kassir, Mohammad M.; DelProposto, Zachary; Dai, Yongming; Sun, Jingyi; Haacke, Mark; Hu, Jiani

    2013-01-01

    Objective To investigate the feasibility of gadolinium (Gd) contrast-enhanced magnetic resonance lymphangiography (MRL) in breast cancer patients within a typical clinical setting, and to establish a Gd-MRL protocol and identify potential MRL biomarkers for differentiating metastatic from non-metastatic lymph nodes. Materials and Methods 32 patients with unilateral breast cancer were enrolled and divided into 4 groups of 8 patients. Groups I, II, and III received 1.0, 0.5, and 0.3 ml of intra...

  3. Microwave Imaging for Breast Cancer Detection

    DEFF Research Database (Denmark)

    Rubæk, Tonny; Fhager, Andreas; Jensen, Peter Damsgaard;

    2011-01-01

    Still more research groups are promoting microwave imaging as a viable supplement or substitution to more conventional imaging modalities. A widespread approach for microwave imaging of the breast is tomographic imaging in which one seeks to reconstruct the distributions of permittivity and...... conductivity in the breast. In this paper two nonlinear tomographic algorithms are compared – one is a single-frequency algorithm and the other is a time-domain algorithm....

  4. Quantitative Clinical Evaluation of a Simultaneous PETI MRI Breast Imaging System

    Energy Technology Data Exchange (ETDEWEB)

    Schlyer D. J.; Schlyer, D.J.

    2013-04-03

    A prototype simultaneous PET-MRI breast scanner has been developed for conducting clinical studies with the goal of obtaining high resolution anatomical and functional information in the same scan which can lead to faster and better diagnosis, reduction of unwanted biopsies, and better patient care.

  5. A CAD System for Identification and Classification of Breast Cancer Tumors in DCE-MR Images Based on Hierarchical Convolutional Neural Networks

    Directory of Open Access Journals (Sweden)

    Reza Rastiboroujeni

    2015-06-01

    Full Text Available In this paper, we propose a computer aided diagnosis (CAD system based on hierarchical convolutional neural networks (HCNNs to discriminate between malignant and benign tumors in breast DCE-MRIs. A HCNN is a hierarchical neural network that operates on two-dimensional images. A HCNN integrates feature extraction and classification processes into one single and fully adaptive structure. It can extract two-dimensional key features automatically, and it is relatively tolerant to geometric and local distortions in input images. We evaluate CNN implementation learning and testing processes based on gradient descent (GD and resilient back-propagation (RPROP approaches. We show that, proposed HCNN with RPROP learning approach provide an effective and robust neural structure to design a CAD base system for breast MRI, and has potential as a mechanism for the evaluation of different types of abnormalities in medical images.

  6. Breast imaging technology: Imaging biochemistry - applications to breast cancer

    International Nuclear Information System (INIS)

    The use of magnetic resonance spectroscopy (MRS) to investigate breast tumour biochemistry in vivo is reviewed. To this end, results obtained both from patients in vivo and from tumour extracts and model systems are discussed. An association has been observed between transformation and an increase in phosphomonoesters (PMEs) detected in the 31P MRS spectrum, as well as an increase in choline-containing metabolites detected in the 1H spectrum. A decrease in PME content after treatment is associated with response to treatment as assessed by tumour volume. Experiments in model systems aimed at understanding the underlying biochemical processes are presented, as well as data indicating the usefulness of MRS in monitoring the uptake and metabolism of some chemotherapeutic agents

  7. Optical imaging for breast cancer prescreening

    Directory of Open Access Journals (Sweden)

    Godavarty A

    2015-07-01

    Full Text Available Anuradha Godavarty,1 Suset Rodriguez,1 Young-Jin Jung,2 Stephanie Gonzalez1 1Optical Imaging Laboratory, Department of Biomedical Engineering, Florida International University, Miami, FL, USA; 2Department of Radiological Science, Dongseo University, Busan, South Korea Abstract: Breast cancer prescreening is carried out prior to the gold standard screening using X-ray mammography and/or ultrasound. Prescreening is typically carried out using clinical breast examination (CBE or self-breast examinations (SBEs. Since CBE and SBE have high false-positive rates, there is a need for a low-cost, noninvasive, non-radiative, and portable imaging modality that can be used as a prescreening tool to complement CBE/SBE. This review focuses on the various hand-held optical imaging devices that have been developed and applied toward early-stage breast cancer detection or as a prescreening tool via phantom, in vivo, and breast cancer imaging studies. Apart from the various optical devices developed by different research groups, a wide-field fiber-free near-infrared optical scanner has been developed for transillumination-based breast imaging in our Optical Imaging Laboratory. Preliminary in vivo studies on normal breast tissues, with absorption-contrasted targets placed in the intramammary fold, detected targets as deep as 8.8 cm. Future work involves in vivo imaging studies on breast cancer subjects and comparison with the gold standard X-ray mammography approach. Keywords: diffuse optical imaging, near-infrared, hand-held devices, breast cancer, prescreening, early detection 

  8. Dose reduction in molecular breast imaging

    Science.gov (United States)

    Wagenaar, Douglas J.; Chowdhury, Samir; Hugg, James W.; Moats, Rex A.; Patt, Bradley E.

    2011-10-01

    Molecular Breast Imaging (MBI) is the imaging of radiolabeled drugs, cells, or nanoparticles for breast cancer detection, diagnosis, and treatment. Screening of broad populations of women for breast cancer with mammography has been augmented by the emergence of breast MRI in screening of women at high risk for breast cancer. Screening MBI may benefit the sub-population of women with dense breast tissue that obscures small tumors in mammography. Dedicated breast imaging equipment is necessary to enable detection of early-stage tumors less than 1 cm in size. Recent progress in the development of these instruments is reviewed. Pixellated CZT for single photon MBI imaging of 99mTc-sestamibi gives high detection sensitivity for early-stage tumors. The use of registered collimators in a near-field geometry gives significantly higher detection efficiency - a factor of 3.6-, which translates into an equivalent dose reduction factor given the same acquisition time. The radiation dose in the current MBI procedure has been reduced to the level of a four-view digital mammography study. In addition to screening of selected sub-populations, reduced MBI dose allows for dual-isotope, treatment planning, and repeated therapy assessment studies in the era of molecular medicine guided by quantitative molecular imaging.

  9. Comparisons of different contrast resolution effects on a computer-aided detection system intended to cluster microcalcifications detected in dense breast images

    OpenAIRE

    Nunes, Fátima L. S.; Schiabel, Hamero; Escarpinati, Mauricio C.; Góes, Cláudio E.

    2001-01-01

    Clustered microcalcifications, which are frequently an important signal of possible cancer, are usually hidden in dense breast images, adding more difficulty in mammogram medical analysis. In this work we evaluate the performance of a previously developed computer-aided detection scheme, modified for application to dense breast images. The main focus of this investigation was on the effect of different contrast resolutions on the processing performance. We have processed dense breast images d...

  10. Appropriate Contrast Enhancement Measures for Brain and Breast Cancer Images

    Directory of Open Access Journals (Sweden)

    Suneet Gupta

    2016-01-01

    Full Text Available Medical imaging systems often produce images that require enhancement, such as improving the image contrast as they are poor in contrast. Therefore, they must be enhanced before they are examined by medical professionals. This is necessary for proper diagnosis and subsequent treatment. We do have various enhancement algorithms which enhance the medical images to different extents. We also have various quantitative metrics or measures which evaluate the quality of an image. This paper suggests the most appropriate measures for two of the medical images, namely, brain cancer images and breast cancer images.

  11. CAD in breast imaging. Application in mammography and MR mammography

    International Nuclear Information System (INIS)

    Computer aided diagnosis systems (CAD-systems) are evaluated in different parts of diagnostic imaging. In breast imaging double reading which is time- and cost spending is necessary. Therefore a lot of studies evaluated the use of CAD-systems in mammography. However the rate of false-positives is too high to implement CAD-systems as double reader in routine work. In the future, improvements in this technique could perhaps change the performance of CAD-systems. (orig.)

  12. BI-RADS update: mammography, breast ultrasound and magnetic resonance imaging of the breast; BI-RADS update: Mammographie, Brustultraschall und Kernspinmammographie

    Energy Technology Data Exchange (ETDEWEB)

    Saleh, A.; Kurz, K.D.; Moedder, U. [Universitaetsklinikum Duesseldorf (Germany). Inst. fuer Diagnostische Radiologie

    2005-12-01

    The Breast Imaging Reporting and Data System (BI-RADS) is a quality assurance tool in breast evaluation. A breast imaging lexicon, which has been defined for mammography breast ultrasound and magnetic resonance imaging of the breast, standardizes terminology used in reporting findings on breast examinations. Every report ends with the assignment of a final assessment category to describe the risk of malignancy and recommend the action to be taken after the history and results of all breast examinations are taken into account. This article gives a short introduction to breast imaging lexica mammography, breast ultrasound, magnetic resonance of the breast and reviews the literature about the clinical usefulness of the BI-RADS. (orig.)

  13. Breast imaging with SoftVue: initial clinical evaluation

    Science.gov (United States)

    Duric, Neb; Littrup, Peter; Li, Cuiping; Roy, Olivier; Schmidt, Steven; Cheng, Xiaoyang; Seamans, John; Wallen, Andrea; Bey-Knight, Lisa

    2014-03-01

    We describe the clinical performance of SoftVue, a breast imaging device based on the principles of ultrasound tomography. Participants were enrolled in an IRB-approved study at Wayne State University, Detroit, MI. The main research findings indicate that SoftVue is able to image the whole uncompressed breast up to cup size H. Masses can be imaged in even the densest breasts with the ability to discern margins and mass shapes. Additionally, it is demonstrated that multi-focal disease can also be imaged. The system was also tested in its research mode for additional imaging capabilities. These tests demonstrated the potential for generating tissue stiffness information for the entire breast using through-transmission data. This research capability differentiates SoftVue from the other whole breast systems on the market. It is also shown that MRI-like images can be generated using alternative processing of the echo data. Ongoing research is focused on validating and quantifying these findings in a larger sample of study participants and quantifying SoftVue's ability to differentiate benign masses from cancer.

  14. SPECT imaging for breast cancer staging

    International Nuclear Information System (INIS)

    Accurate staging in breast cancer, including tumour sizing and the assessment of nodal and distant metastases, is required in order to plan surgery and post-operative therapy. Medical imaging techniques have made an important contribution to the diagnosis of carcinoma of the breast and the evaluation of local, regional and distant metastases. The study is aimed at establishing certain aspects of the diagnostic importance and priority of single photon emission computed tomography (SPECT) imaging in breast cancer. SPECT was carried out just after planar scintigraphy and then after intravenous injection of different radiopharmaceuticals in 45 women with histologically confirmed post-operation breast cancer. In 21 patients under loco-regional control of the disease before and/or after surgery, planar mammoscintigraphy and SPECT were conducted after intravenous injection of 99Tcm-MIBI (methoxyisobutyl isonitrile) or 99Tcm-anti-CEA (carcinoembryonic antigen) monoclonal antibody (MoAb). Bone SPECT was carried out in 24 patients when whole body scintigraphy was unable to determine the exact localization of bone metastatic lesions in the skull, thorax and pelvis. The results suggest that SPECT with 99Tcm-MIBI and 99Tcm-anti-CEA MoAb has high sensitivity and improves the results of conventional planar scintigraphy for breast cancer detection. Breast SPECT is a preferable method for tumour and lymph node imaging because of the excellent separation of the deep breast structures from the myocardium in the left breast and of the right breast from the liver, thus improving the resolution of small, deep seated lesions. SPECT improves breast cancer staging, and determines the tumour, nodule and metastasis categories, which are important for the treatment strategy and prognosis of the disease. (author). 10 refs, 3 figs, 2 tabs

  15. Evaluation of Immunohistochemistry and Silver-Enhanced In Situ Hybridization Results for HER2/neu Manually and with Image Analysis System in Human Breast Cancer

    Directory of Open Access Journals (Sweden)

    Doğuş ÖZDEMİR

    2010-09-01

    Full Text Available Objective: HER2/neu (ErbB2 gene status is one of the important information while planing terapy in breast carcinoma. For HER2/ neu testing there is not standart assay that has been agreed on. Silver enhanced in situ hybridization is a cantitative and highly reproducible assay. Immunohistochemistry is a cheap and easy assay that has disadvantage of being less reproducible. Recently developed pathologist assisted computerized image analysis systems decrease the ratio of subjectivity due to manual evaluation, enable tele-consultation and make it easy to evaluate tumor morphology and markers. Our aim is to investigate the consistency of manual and computerized interpretation of the results of immunohistochemistry and silver enhanced in situ hybridization.Material and Method: Immunohistochemisty and silver enhanced in situ hybridization of 73 invasive breast carcinoma results were evaluated manually to determine HER2/neu status. Later, silver enhanced in situ hybridization and immunohistochemistry results were reevaluated with Ventana Image Analysis System. Afterwards correlation of both methods with image analysis system and manuel interpretation were calculated.Result: All cases were score 2 with immunohistochemistry. With image analysis system, 5 cases were score 1, 56 cases were score 2 and 12 cases were score 3. When in situ hybridization results were reevaluated with image analysis system, 6 cases were discordant compared with manual interpretation.Conclusion: The correlation rate of immunohistochemistry interpretation results between manuel method and image analysis system was %76; but silver enhanced in situ hybridization interpretation results between manuel method and image analysis system were %91 concordant and it was statistically significant (k= 0.832 and p<0.001.

  16. A statistical, task-based evaluation method for three-dimensional x-ray breast imaging systems using variable-background phantoms

    International Nuclear Information System (INIS)

    Purpose: For the last few years, development and optimization of three-dimensional (3D) x-ray breast imaging systems, such as digital breast tomosynthesis (DBT) and computed tomography, have drawn much attention from the medical imaging community, either academia or industry. However, there is still much room for understanding how to best optimize and evaluate the devices over a large space of many different system parameters and geometries. Current evaluation methods, which work well for 2D systems, do not incorporate the depth information from the 3D imaging systems. Therefore, it is critical to develop a statistically sound evaluation method to investigate the usefulness of inclusion of depth and background-variability information into the assessment and optimization of the 3D systems. Methods: In this paper, we present a mathematical framework for a statistical assessment of planar and 3D x-ray breast imaging systems. Our method is based on statistical decision theory, in particular, making use of the ideal linear observer called the Hotelling observer. We also present a physical phantom that consists of spheres of different sizes and materials for producing an ensemble of randomly varying backgrounds to be imaged for a given patient class. Lastly, we demonstrate our evaluation method in comparing laboratory mammography and three-angle DBT systems for signal detection tasks using the phantom's projection data. We compare the variable phantom case to that of a phantom of the same dimensions filled with water, which we call the uniform phantom, based on the performance of the Hotelling observer as a function of signal size and intensity. Results: Detectability trends calculated using the variable and uniform phantom methods are different from each other for both mammography and DBT systems. Conclusions: Our results indicate that measuring the system's detection performance with consideration of background variability may lead to differences in system performance

  17. Multimodality imaging and state-of-art GPU technology in discriminating benign from malignant breast lesions on real time decision support system

    International Nuclear Information System (INIS)

    The aim of this study was to design a pattern recognition system for assisting the diagnosis of breast lesions, using image information from Ultrasound (US) and Digital Mammography (DM) imaging modalities. State-of-art computer technology was employed based on commercial Graphics Processing Unit (GPU) cards and parallel programming. An experienced radiologist outlined breast lesions on both US and DM images from 59 patients employing a custom designed computer software application. Textural features were extracted from each lesion and were used to design the pattern recognition system. Several classifiers were tested for highest performance in discriminating benign from malignant lesions. Classifiers were also combined into ensemble schemes for further improvement of the system's classification accuracy. Following the pattern recognition system optimization, the final system was designed employing the Probabilistic Neural Network classifier (PNN) on the GPU card (GeForce 580GTX) using CUDA programming framework and C++ programming language. The use of such state-of-art technology renders the system capable of redesigning itself on site once additional verified US and DM data are collected. Mixture of US and DM features optimized performance with over 90% accuracy in correctly classifying the lesions

  18. ClearPEM: prototype PET device dedicated to breast imaging

    CERN Multimedia

    Joao Varela

    2009-01-01

    Clinical trials have begun in Portugal on a new breast imaging system (ClearPEM) using positron emission tomography (PET). The system, developed by a Portuguese consortium in collaboration with CERN and laboratories participating in the Crystal Clear collaboration, will detect even the smallest tumours and thus help avoid unnecessary biopsies.

  19. Sexuality and body image in younger women with breast cancer.

    Science.gov (United States)

    Schover, L R

    1994-01-01

    Breast cancer has the potential to be most devastating to the sexual function and self-esteem of premenopausal women. Nevertheless, not one study has systematically compared the impact of breast cancer treatment on sexual issues across age groups. Research shows that younger women with breast cancer have more severe emotional distress than older cohorts. In a group of patients seeking sexual rehabilitation in a cancer center, younger couples were more distressed, but also had the best prognosis with treatment. In theory, loss of a breast or poor breast appearance would be more distressing to women whose youth gives them high expectations for physical beauty. Seeking new dating relationships after breast cancer treatment is a special stressor for single women. Potential infertility also may impact on a woman's self-concept as a sexual person. Systemic treatment disrupts sexual function by causing premature menopause, with estrogen loss leading to vaginal atrophy and androgen loss perhaps decreasing sexual desire and arousability. Research on mastectomy versus breast conservation across all ages of women has demonstrated that general psychological distress, marital satisfaction, and overall sexual frequency and function do not differ between the two treatment groups. Women with breast conservation do rate their body image more highly and are more comfortable with nudity and breast caressing. There is some evidence that breast conservation offers more psychological "protection" for younger women. Research on the impact of breast reconstruction is sparse, but reveals similar patterns. Future studies should use rigorous methodology and focus on the impact of premature menopause and the effectiveness of sexual rehabilitation for younger women. PMID:7999462

  20. Imaging features of complex sclerosing lesions of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Myong, Joo Hwa; Choi, Byung Gil; Kim, Sung Hun; Kang, Bong Joo; Lee, Ah Won; Song, Byung Joo [Seoul St. Mary' s Hospital, The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    2014-03-15

    The purpose of this study was to evaluate the imaging features of complex sclerosing lesions of the breast and to assess the rate of upgrade to breast cancer. From March 2008 to May 2012, seven lesions were confirmed as complex sclerosing lesions by ultrasonography-guided core needle biopsy. Final results by either surgical excision or follow-up imaging studies were reviewed to assess the rate of upgrade to breast cancer. Two radiologists retrospectively analyzed the imaging findings according to the Breast Imaging Reporting and Data System classification. Five lesions underwent subsequent surgical excision and two of them revealed ductal carcinoma in situ (n=1) and invasive ductal carcinoma (n=1). Our study showed a breast cancer upgrade rate of 28.6% (2 of 7 lesions). Two lesions were stable on imaging follow-up beyond 1 year. The mammographic features included masses (n=4, 57.1%), architectural distortion (n=2, 28.6%), and focal asymmetry (n=1, 14.3%). Common B-mode ultrasonographic features were irregular shape (n=6, 85.7%), spiculated margin (n=5, 71.4 %), and hypoechogenicity (n=7, 100%). The final assessment categories were category 4 (n=6, 85.7%) and category 5 (n=1, 14.3%). The complex sclerosing lesions were commonly mass-like on mammography and showed the suspicious ultrasonographic features of category 4. Due to a high underestimation rate, all complex sclerosing lesions by core needle biopsy should be excised.

  1. The choice of radiopharmaceutical to image breast cancer

    International Nuclear Information System (INIS)

    Breast function and development are regulated by a network of local and systemic signals which can exert either stimulatory or inhibitory effects. Many of these signals are mediated by topically produced hormones and cytokines, which are both believed to be part of complex feedback loops. These local feedback loops also play an integral part in the vascularization and invasion of malignant breast tumours. More specifically, it has been demonstrated that the disruption of physiological negative feedback loops in breast tissue may result in the loss of cell cycle control and eventually leading to local breakdown of the adjacent stroma implying interactions between breast tumour cells and their stromal environment. Novel anticancer strategies selectively interacting with breast tumour vascularization and metastasis, include blocking monoclonal antibodies, peptide hormone antagonists, peptide/toxin fusion proteins and inhibitors of signal transduction. As most of these novel drugs are cytostatic, objective response as measured by morphological imaging modalities, e.g., Computed Tomography (CT) or Magnetic Resonance Imaging (MRI) cannot be utilized as a surrogate marker for drug development, nor for clinical decision- making. Accordingly, in order to maximize the benefit from these new treatment paradigms, novel objective markers of therapeutic success are mandatory. This editorial focuses on recently developed radioligands for SPECT imaging as potential markers for the in vivo assessment of ongoing angiogenesis and metastasis in patients suffering from breast carcinoma

  2. Intelligent CAD System for Automatic Detection of Mitotic Cells from Breast Cancer Histology Slide Images Based on Teaching-Learning-Based Optimization

    Directory of Open Access Journals (Sweden)

    Ramin Nateghi

    2014-01-01

    Full Text Available This paper introduces a computer-assisted diagnosis (CAD system for automatic mitosis detection from breast cancer histopathology slide images. In this system, a new approach for reducing the number of false positives is proposed based on Teaching-Learning-Based optimization (TLBO. The proposed CAD system is implemented on the histopathology slide images acquired by Aperio XT scanner (scanner A. In TLBO algorithm, the number of false positives (falsely detected nonmitosis candidates as mitosis ones is defined as a cost function and, by minimizing it, many of nonmitosis candidates will be removed. Then some color and texture (textural features such as those derived from cooccurrence and run-length matrices are extracted from the remaining candidates and finally mitotic cells are classified using a specific support vector machine (SVM classifier. The simulation results have proven the claims about the high performance and efficiency of the proposed CAD system.

  3. Knowledge-Guided Semantic Indexing of Breast Cancer Histopathology Images

    OpenAIRE

    Tutac, Adina,; Racoceanu, Daniel; Putti, Thomas; Xiong, Wei; Leow, Wee-Kheng; Cretu, Vladimir

    2008-01-01

    Narrowing the semantic gap represents one of the most outstanding challenges in medical image analysis and indexing. This paper introduces a medical knowledge – guided paradigm for semantic indexing of histopathology images, applied to breast cancer grading (BCG). Our method improves pathologists' current manual procedures consistency by employing a semantic indexing technique, according to a rule-based decision system related to Nottingham BCG system. The challenge is to move from the medica...

  4. The surgically altered breast: imaging technique and findings

    OpenAIRE

    Thongchai, Poonpit

    2014-01-01

    Early diagnosis of breast cancer is the most importance factor that improve patient prognosis. Mammography has been proven in various randomized control trial as an effective screening tool for breast cancer. However, with the increasing of various breast surgical procedures such as breast augmentation, reduction mammoplasty and reconstruction, it may result in more challenging in surveillance and screening of the breast cancer. Imaging appearances of breast augmentation and other surgical al...

  5. Opto-acoustic breast imaging with co-registered ultrasound

    Science.gov (United States)

    Zalev, Jason; Clingman, Bryan; Herzog, Don; Miller, Tom; Stavros, A. Thomas; Oraevsky, Alexander; Kist, Kenneth; Dornbluth, N. Carol; Otto, Pamela

    2014-03-01

    We present results from a recent study involving the ImagioTM breast imaging system, which produces fused real-time two-dimensional color-coded opto-acoustic (OA) images that are co-registered and temporally inter- leaved with real-time gray scale ultrasound using a specialized duplex handheld probe. The use of dual optical wavelengths provides functional blood map images of breast tissue and tumors displayed with high contrast based on total hemoglobin and oxygen saturation of the blood. This provides functional diagnostic information pertaining to tumor metabolism. OA also shows morphologic information about tumor neo-vascularity that is complementary to the morphological information obtained with conventional gray scale ultrasound. This fusion technology conveniently enables real-time analysis of the functional opto-acoustic features of lesions detected by readers familiar with anatomical gray scale ultrasound. We demonstrate co-registered opto-acoustic and ultrasonic images of malignant and benign tumors from a recent clinical study that provide new insight into the function of tumors in-vivo. Results from the Feasibility Study show preliminary evidence that the technology may have the capability to improve characterization of benign and malignant breast masses over conventional diagnostic breast ultrasound alone and to improve overall accuracy of breast mass diagnosis. In particular, OA improved speci city over that of conventional diagnostic ultrasound, which could potentially reduce the number of negative biopsies performed without missing cancers.

  6. Breast reconstruction - methods and imaging

    International Nuclear Information System (INIS)

    Silicon implants are used for breast reconstruction or for cosmetic operations. The contribution outlines the role of mammography, sonography and MR for defect assessment, tumour detection and monitoring after prosthesis implantation. Instrument adjustment for mammographic screening of patients with implants is gone into. Autologic reconstruction techniques and protocols of secondary and tertiary early detection are presented. (orig.)

  7. Detecting breast microcalcifications using super-resolution ultrasound imaging: a clinical study

    Science.gov (United States)

    Huang, Lianjie; Labyed, Yassin; Hanson, Kenneth; Sandoval, Daniel; Pohl, Jennifer; Williamson, Michael

    2013-03-01

    Imaging breast microcalcifications is crucial for early detection and diagnosis of breast cancer. It is challenging for current clinical ultrasound to image breast microcalcifications. However, new imaging techniques using data acquired with a synthetic-aperture ultrasound system have the potential to significantly improve ultrasound imaging. We recently developed a super-resolution ultrasound imaging method termed the phase-coherent multiple-signal classification (PC-MUSIC). This signal subspace method accounts for the phase response of transducer elements to improve image resolution. In this paper, we investigate the clinical feasibility of our super-resolution ultrasound imaging method for detecting breast microcalcifications. We use our custom-built, real-time synthetic-aperture ultrasound system to acquire breast ultrasound data for 40 patients whose mammograms show the presence of breast microcalcifications. We apply our super-resolution ultrasound imaging method to the patient data, and produce clear images of breast calcifications. Our super-resolution ultrasound PC-MUSIC imaging with synthetic-aperture ultrasound data can provide a new imaging modality for detecting breast microcalcifications in clinic without using ionizing radiation.

  8. Breast imaging technology: Application of magnetic resonance imaging to angiogenesis in breast cancer

    International Nuclear Information System (INIS)

    Magnetic resonance imaging (MRI) techniques enable vascular function to be mapped with high spatial resolution. Current methods for imaging in breast cancer are described, and a review of recent studies that compared dynamic contrast-enhanced MRI with histopathological indicators of tumour vascular status is provided. These studies show correlation between in vivo dynamic contrast measurements and in vitro histopathology. Dynamic contrast enhanced MRI is also being applied to assessment of the response of breast tumours to treatment

  9. Computer-aided detection system for clustered microcalcifications in digital breast tomosynthesis using joint information from volumetric and planar projection images

    International Nuclear Information System (INIS)

    We propose a novel approach for the detection of microcalcification clusters (MCs) using joint information from digital breast tomosynthesis (DBT) volume and planar projection (PPJ) image. A data set of 307 DBT views was collected with IRB approval using a prototype DBT system. The system acquires 21 projection views (PVs) from a wide tomographic angle of 60° (60°-21PV) at about twice the dose of a digital mammography (DM) system, which allows us the flexibility of simulating other DBT acquisition geometries using a subset of the PVs. In this study, we simulated a 30° DBT geometry using the central 11 PVs (30°-11PV). The narrower tomographic angle is closer to DBT geometries commercially available or under development and the dose is matched approximately to that of a DM. We developed a new joint-CAD system for detection of clustered microcalcifications. The DBT volume was reconstructed with a multiscale bilateral filtering regularized method and a PPJ image was generated from the reconstructed volume. Task-specific detection strategies were designed to combine information from the DBT volume and the PPJ image. The data set was divided into a training set (127 views with MCs) and an independent test set (104 views with MCs and 76 views without MCs). The joint-CAD system outperformed the individual CAD systems for DBT volume or PPJ image alone; the differences in the test performances were statistically significant (p  <  0.05) using JAFROC analysis. (paper)

  10. Mammographic evaluation of suspicious malignant lesions based on ACR(American College of Radiology) breast imaging reporting and data system(BI-RADS)

    International Nuclear Information System (INIS)

    The purpose of this study was to assess the mammographic features and pathologic outcome of category 4 lesions using the Breast Imaging Reporting and Data System(BI-RADS), and to evaluate the significance of final assessment categories. Using BI-RADS, the interpretations of 8,134 mammograms acquired between January 1997 and May 1998 were categorized. From among 161 lesions categorized as '4' ('suspicious abnormality') and pathologically confirmed by surgery or biopsy, we analysed 113, found in 66 patients. The pathologic outcome of these 113 lesions was as follows:infiltrating ductal carcinoma, 17.7%(20/113); DCIS(ductal carcinoma in sitv), 8.0%(9/113); ADH(atypical ductal hyperplasia), 5.3%(6/113); DEH(ductal epithelial hyperplasia), 1.8%(2/113); ductectasia, 0.9%(1/113), FCD(fibrocystic change), 27.4%(31/113); firoadenoma, 7.1%(8/113); stromal fibrosis, 9.7%(11/113); normal parenchyma, 7.1%(8/113); other pathology, 15.0%(17/113). The most frequent mammographic features of BI-RADS category 4 lesions were irregular mass shape(41.2%), spiculated mass margin(52.3%), amorphous calcification(47.3%) and clustered calcification distribution(37.1%). Because category 4 lesions account for about 25.7% of all breast malignancies, mammographic lesions in this category ('suspicious abnormality') should be considered for supplementary study and breast biopsy rather than short-term follow-up. Initial pathologic findings can thus be confirmed

  11. Design and evaluation of a laboratory prototype system for 3D photoacoustic full breast tomography

    OpenAIRE

    Xia, W; Piras, D; Singh, M. K. A.; van Hespen, J. C. G.; Van Leeuwen, T. G.; Steenbergen, W Van; Manohar, S.

    2013-01-01

    Photoacoustic imaging can visualize vascularization-driven optical absorption contrast with great potential for breast cancer detection and diagnosis. State-of-the-art photoacoustic breast imaging systems are promising but are limited either by only a 2D imaging capability or by an insufficient imaging field-of-view (FOV). We present a laboratory prototype system designed for 3D photoacoustic full breast tomography, and comprehensively characterize it and evaluate its performance in imaging p...

  12. Efficient iterative image reconstruction algorithm for dedicated breast CT

    Science.gov (United States)

    Antropova, Natalia; Sanchez, Adrian; Reiser, Ingrid S.; Sidky, Emil Y.; Boone, John; Pan, Xiaochuan

    2016-03-01

    Dedicated breast computed tomography (bCT) is currently being studied as a potential screening method for breast cancer. The X-ray exposure is set low to achieve an average glandular dose comparable to that of mammography, yielding projection data that contains high levels of noise. Iterative image reconstruction (IIR) algorithms may be well-suited for the system since they potentially reduce the effects of noise in the reconstructed images. However, IIR outcomes can be difficult to control since the algorithm parameters do not directly correspond to the image properties. Also, IIR algorithms are computationally demanding and have optimal parameter settings that depend on the size and shape of the breast and positioning of the patient. In this work, we design an efficient IIR algorithm with meaningful parameter specifications and that can be used on a large, diverse sample of bCT cases. The flexibility and efficiency of this method comes from having the final image produced by a linear combination of two separately reconstructed images - one containing gray level information and the other with enhanced high frequency components. Both of the images result from few iterations of separate IIR algorithms. The proposed algorithm depends on two parameters both of which have a well-defined impact on image quality. The algorithm is applied to numerous bCT cases from a dedicated bCT prototype system developed at University of California, Davis.

  13. Compositional breast imaging using a dual-energy mammography protocol

    International Nuclear Information System (INIS)

    Purpose: Mammography has a low sensitivity in dense breasts due to low contrast between malignant and normal tissue confounded by the predominant water density of the breast. Water is found in both adipose and fibroglandular tissue and constitutes most of the mass of a breast. However, significant protein mass is mainly found in the fibroglandular tissue where most cancers originate. If the protein compartment in a mammogram could be imaged without the influence of water, the sensitivity and specificity of the mammogram may be improved. This article describes a novel approach to dual-energy mammography, full-field digital compositional mammography (FFDCM), which can independently image the three compositional components of breast tissue: water, lipid, and protein. Methods: Dual-energy attenuation and breast shape measures are used together to solve for the three compositional thicknesses. Dual-energy measurements were performed on breast-mimicking phantoms using a full-field digital mammography unit. The phantoms were made of materials shown to have similar x-ray attenuation properties of the compositional compartments. They were made of two main stacks of thicknesses around 2 and 4 cm. Twenty-six thickness and composition combinations were used to derive the compositional calibration using a least-squares fitting approach. Results: Very high accuracy was achieved with a simple cubic fitting function with root mean square errors of 0.023, 0.011, and 0.012 cm for the water, lipid, and protein thicknesses, respectively. The repeatability (percent coefficient of variation) of these measures was tested using sequential images and was found to be 0.5%, 0.5%, and 3.3% for water, lipid, and protein, respectively. However, swapping the location of the two stacks of the phantom on the imaging plate introduced further errors showing the need for more complete system uniformity corrections. Finally, a preliminary breast image is presented of each of the compositional

  14. Pitfalls of Imaging in Breast Cancer Diagnosis:

    Directory of Open Access Journals (Sweden)

    M. Kalantari

    2009-01-01

    Full Text Available "nWith the introduction of mammography for early diagnosis of breast cancer a new horizon is created in breast cancer diagnosis. Instead of palpated easy-to-manage lesions, now the surgeon is confronted with non palpable findings on the mammogram, sometimes very difficult for decision, that highlight the importance of the role of the interventional breast radiologist in the team and surgeon-radiologist collaboration. "nThis close collaboration would eliminate many difficulties in correct cancer diagnosis, both for the radiologist and the surgeon. "nIn this study, reviewing interesting difficult cases during the last 8 years, we present all pitfalls in imaging that can be avoided in majority by team work collaboration.  

  15. Combined photoacoustic and ultrasound imaging of human breast in vivo in the mammographic geometry

    Science.gov (United States)

    Xie, Zhixing; Lee, Won-Mean; Hooi, Fong Ming; Fowlkes, J. Brian; Pinsky, Renee W.; Mueller, Dean; Wang, Xueding; Carson, Paul L.

    2013-03-01

    This photoacoustic volume imaging (PAVI) system is designed to study breast cancer detection and diagnosis in the mammographic geometry in combination with automated 3D ultrasound (AUS). The good penetration of near-infrared (NIR) light and high receiving sensitivity of a broad bandwidth, 572 element, 2D PVDF array at a low center-frequency of 1MHz were utilized with 20 channel simultaneous acquisition. The feasibility of this system in imaging optically absorbing objects in deep breast tissues was assessed first through experiments on ex vivo whole breasts. The blood filled pseudo lesions were imaged at depths up to 49 mm in the specimens. In vivo imaging of human breasts has been conducted. 3D PAVI image stacks of human breasts were coregistered and compared with 3D ultrasound image stacks of the same breasts. Using the designed system, PAVI shows satisfactory imaging depth and sensitivity for coverage of the entire breast when imaged from both sides with mild compression in the mammographic geometry. With its unique soft tissue contrast and excellent sensitivity to the tissue hemodynamic properties of fractional blood volume and blood oxygenation, PAVI, as a complement to 3D ultrasound and digital tomosynthesis mammography, might well contribute to detection, diagnosis and prognosis for breast cancer.

  16. A review of breast tomosynthesis. Part I. The image acquisition process

    Energy Technology Data Exchange (ETDEWEB)

    Sechopoulos, Ioannis [Department of Radiology and Imaging Sciences, Hematology and Medical Oncology and Winship Cancer Institute, Emory University, 1701 Upper Gate Drive Northeast, Suite 5018, Atlanta, Georgia 30322 (United States)

    2013-01-15

    Mammography is a very well-established imaging modality for the early detection and diagnosis of breast cancer. However, since the introduction of digital imaging to the realm of radiology, more advanced, and especially tomographic imaging methods have been made possible. One of these methods, breast tomosynthesis, has finally been introduced to the clinic for routine everyday use, with potential to in the future replace mammography for screening for breast cancer. In this two part paper, the extensive research performed during the development of breast tomosynthesis is reviewed, with a focus on the research addressing the medical physics aspects of this imaging modality. This first paper will review the research performed on the issues relevant to the image acquisition process, including system design, optimization of geometry and technique, x-ray scatter, and radiation dose. The companion to this paper will review all other aspects of breast tomosynthesis imaging, including the reconstruction process.

  17. Polyvinyl chloride plastisol breast phantoms for ultrasound imaging.

    Science.gov (United States)

    de Carvalho, Isabela Miller; De Matheo, Lucas Lobianco; Costa Júnior, José Francisco Silva; Borba, Cecília de Melo; von Krüger, Marco Antonio; Infantosi, Antonio Fernando Catelli; Pereira, Wagner Coelho de Albuquerque

    2016-08-01

    Ultrasonic phantoms are objects that mimic some features of biological tissues, allowing the study of their interactions with ultrasound (US). In the diagnostic-imaging field, breast phantoms are an important tool for testing performance and optimizing US systems, as well as for training medical professionals. This paper describes the design and manufacture of breast lesions by using polyvinyl chloride plastisol (PVCP) as the base material. Among the materials available for this study, PVCP was shown to be stable, durable, and easy to handle. Furthermore, it is a nontoxic, nonpolluting, and low-cost material. The breast's glandular tissue (image background) was simulated by adding graphite powder with a concentration of 1% to the base material. Mixing PVCP and graphite powder in differing concentrations allows one to simulate lesions with different echogenicity patterns (anechoic, hypoechoic, and hyperechoic). From this mixture, phantom materials were obtained with speed of sound varying from 1379.3 to 1397.9ms(-1) and an attenuation coefficient having values between 0.29 and 0.94dBcm(-1) for a frequency of 1MHz at 24°C. A single layer of carnauba wax was added to the lesion surface in order to evaluate its applicability for imaging. The images of the phantoms were acquired using commercial ultrasound equipment; a specialist rated the images, elaborating diagnoses representative of both benign and malignant lesions. The results indicated that it was possible to easily create a phantom by using low-cost materials, readily available in the market and stable at room temperature, as the basis of ultrasonic phantoms that reproduce the image characteristics of fatty breast tissue and typical lesions of the breast. PMID:27153374

  18. MR imaging of the breast using Gd-DTPA

    International Nuclear Information System (INIS)

    One hundred selected patients underwent preoperative MR imaging of the breast Gd-DTPA. All carcinomas, fibroadenomas, and instances of mastitis enhanced significantly. Normal breast tissue, nonproliferative dysplasia, and scar tissue did not enhance. Borderline focal or generalized enhancement has been observed in cases of focal or generalized proliferative dysplasia. Compared to mammography, MR imaging yielded significant additional information in 20% of cases; the added information concerned mostly dense breasts and breasts with posttreatment changes. No additional information was obtained in fatty breasts, because of the high accuracy of mammography, and in breasts with proliferative dysplasia, because of their generalized enhancement

  19. CT guided diffuse optical tomography for breast cancer imaging

    Science.gov (United States)

    Baikejiang, Reheman; Zhang, Wei; Zhu, Dianwen; Li, Changqing

    2016-03-01

    Diffuse optical tomography (DOT) has attracted attentions in the last two decades due to its intrinsic sensitivity in imaging chromophores of tissues such as blood, water, and lipid. However, DOT has not been clinically accepted yet due to its low spatial resolution caused by strong optical scattering in tissues. Structural guidance provided by an anatomical imaging modality enhances the DOT imaging substantially. Here, we propose a computed tomography (CT) guided multispectral DOT imaging system for breast cancer detection. To validate its feasibility, we have built a prototype DOT imaging system which consists of a laser at wavelengths of 650 and an electron multiplying charge coupled device (EMCCD) camera. We have validated the CT guided DOT reconstruction algorithms with numerical simulations and phantom experiments, in which different imaging setup parameters, such as projection number of measurements, the width of measurement patch, have been investigated. Our results indicate that an EMCCD camera with air cooling is good enough for the transmission mode DOT imaging. We have also found that measurements at six projections are sufficient for DOT to reconstruct the optical targets with 4 times absorption contrast when the CT guidance is applied. Finally, we report our effort and progress on the integration of the multispectral DOT imaging system into a breast CT scanner.

  20. An introduction to microwave imaging for breast cancer detection

    CERN Document Server

    Conceição, Raquel Cruz; O'Halloran, Martin

    2016-01-01

    This book collates past and current research on one of the most promising emerging modalities for breast cancer detection. Readers will discover how, as a standalone technology or in conjunction with another modality, microwave imaging has the potential to provide reliable, safe and comfortable breast exams at low cost. Current breast imaging modalities include X- ray, Ultrasound, Magnetic Resonance Imaging, and Positron Emission Tomography. Each of these methods suffers from limitations, including poor sensitivity or specificity, high cost, patient discomfort, and exposure to potentially harmful ionising radiation. Microwave breast imaging is based on a contrast in the dielectric properties of breast tissue that exists at microwave frequencies. The book begins by considering the anatomy and dielectric properties of the breast, contrasting historical and recent studies. Next, radar-based breast imaging algorithms are discussed, encompassing both early-stage artefact removal, and data independent and adaptive ...

  1. Metaplastic carcinoma of the breast: multimodality imaging and histopathologic assessment

    International Nuclear Information System (INIS)

    Background Metaplastic carcinomas are ductal carcinomas that display metaplastic transformation of the glandular epithelium to non-glandular mesenchymal tissue. Metaplastic carcinoma has a poorer prognosis than most other breast cancers, so the differential diagnosis is important. Although many clinical and pathologic findings have been reported, to our knowledge, few imaging findings related to metaplastic carcinoma have been reported. Purpose To investigate whole-breast imaging findings, including mammography, sonography, MRI, and pathologic findings, including immunohistochemical studies of metaplastic carcinomas of the breast. Material and Methods We analyzed 33 cases of metaplastic carcinoma between January 2001 and January 2011. Mammography, ultrasonography, and MRI were recorded retrospectively using the American College of Radiology (ACR) breast imaging reporting and data system (BI-RADS) lexicon. Immunohistochemical studies of estrogen receptor (ER), progesterone receptor (PR), p53, and C-erbB-2 were performed. Results The most common mammographic findings were oval shape (37%), circumscribed margin (59%), and high density (74%). The most common sonogfindings were irregular shape (59.4%), microlobulated margin (41%), complex echogenicity (81%), parallel orientation (97%), and posterior acoustic enhancement (50%). Axillary lymph node metastases were noted for 25% of the sonographic examinations. On MRI, the most common findings of margin and shape were irregularity (57% and 52.4%, respectively). High signal intensity was the most common finding on T2-weighted images (57%). Immunohistochemical profile was negative for ER (91%, 29/32) and PR (81%, 26/32). Conclusion Metaplastic carcinomas might display more benign features and less axillary lymph node metastasis than IDC. High signal intensity on T2 MRI images and hormone receptor negativity would be helpful in differentiating this tumor from other breast cancers

  2. Development of anatomically and dielectrically accurate breast phantoms for microwave imaging applications

    Science.gov (United States)

    O'Halloran, M.; Lohfeld, S.; Ruvio, G.; Browne, J.; Krewer, F.; Ribeiro, C. O.; Inacio Pita, V. C.; Conceicao, R. C.; Jones, E.; Glavin, M.

    2014-05-01

    Breast cancer is one of the most common cancers in women. In the United States alone, it accounts for 31% of new cancer cases, and is second only to lung cancer as the leading cause of deaths in American women. More than 184,000 new cases of breast cancer are diagnosed each year resulting in approximately 41,000 deaths. Early detection and intervention is one of the most significant factors in improving the survival rates and quality of life experienced by breast cancer sufferers, since this is the time when treatment is most effective. One of the most promising breast imaging modalities is microwave imaging. The physical basis of active microwave imaging is the dielectric contrast between normal and malignant breast tissue that exists at microwave frequencies. The dielectric contrast is mainly due to the increased water content present in the cancerous tissue. Microwave imaging is non-ionizing, does not require breast compression, is less invasive than X-ray mammography, and is potentially low cost. While several prototype microwave breast imaging systems are currently in various stages of development, the design and fabrication of anatomically and dielectrically representative breast phantoms to evaluate these systems is often problematic. While some existing phantoms are composed of dielectrically representative materials, they rarely accurately represent the shape and size of a typical breast. Conversely, several phantoms have been developed to accurately model the shape of the human breast, but have inappropriate dielectric properties. This study will brie y review existing phantoms before describing the development of a more accurate and practical breast phantom for the evaluation of microwave breast imaging systems.

  3. 高频超声、乳腺X线检查及乳腺血氧功能成像在乳腺肿块诊断中的价值%The clinical value of high frequency ultrasound, mammography and breast blood-oxygen function imaging system in diagnosis of breast masses

    Institute of Scientific and Technical Information of China (English)

    郑一君; 张渊; 单君; 施秀荣; 贾瑱熙; 江泉

    2013-01-01

    Objective To compare the diagnostic value of high frequency ultrasound,mammography and breast blood-oxygen function imaging system in diagnosis of breast masses.Methods The images of 89 breast masses by high frequency ultrasound,mammography and breast blood-oxygen function imaging system were reviewed.The study compared the sensibilities and specificities of the three methods in the masses and analyzed their cause of missed diagnosis.Results The sensitivity of the diagnosis of breast cancer by high frequency ultrasound,mammography and breast blood-oxygen function imaging system were 80.00%,70.00% and 50.00%,respectively.The specificity of the diagnosis of breast cancer by them were 94.94%,98.73% and 97.47%,respectively.There were sigmfiacant differences in diagnosis of breast benign lesion among the high frequency ultrasound,mammography and breast blood-oxygen function imaging system.The sensitivity of high frequency ultrasound in detecting fibroadenoma of breast was 98.11% higher than the other methods.Mammography was insensitive to the benign breast lesions,but its specificity was high.Conclusions High frequency ultrasound,mammography and breast blood-oxygen function imaging system are the highly effective diagnostic tool for breast cancer,but the diagnostic value of mammography and breast blood-oxygen in breast fibroadenoma and in cystic disease of breast aren' t high.Breast blood-oxygen function imaging system can enhance the accuracy of the diagnosis of mammary inflammation.%目的 比较高频超声、乳腺X线检查以及乳腺血氧功能成像在乳腺肿块诊断中的价值.方法 回顾性分析高频超声、乳腺X线检查及乳腺血氧功能成像在89例乳腺肿块中的诊断结果,比较它们诊断各类乳腺病变的敏感性和特异性,并分析漏诊原因.结果 高频超声、乳腺X线检查以及乳腺血氧功能成像对乳腺癌的敏感性分别为80.00%、70.00%、50.00%;特异性分别为94.94%、98.73

  4. Molecular Imaging of Biomarkers in Breast Cancer

    Science.gov (United States)

    Ulaner, Gary A.; Riedl, Chris C.; Dickler, Maura N.; Jhaveri, Komal; Pandit-Taskar, Neeta; Weber, Wolfgang

    2016-01-01

    The success of breast cancer therapy is ultimately defined by clinical endpoints such as survival. It is valuable to have biomarkers that can predict the most efficacious therapies or measure response to therapy early in the course of treatment. Molecular imaging has a promising role in complementing and overcoming some of the limitations of traditional biomarkers by providing the ability to perform noninvasive, repeatable whole-body assessments. The potential advantages of imaging biomarkers are obvious and initial clinical studies have been promising, but proof of clinical utility still requires prospective multicenter clinical trials. PMID:26834103

  5. Tactile imaging of palpable breast cancer

    Science.gov (United States)

    Srikanchana, Rujirutana; Wang, Yue J.; Freedman, Matthew T.; Nguyen, Charles C.

    2002-05-01

    This paper presents the development of a prototype Tactile Mapping Device (TMD) system comprised mainly of a tactile sensor array probe (TSAP), a 3-D camera, and a force/torque sensor, which can provide the means to produce tactile maps of the breast lumps during a breast palpation. Focusing on the key tactile topology features for breast palpation such as spatial location, size/shape of the detected lesion, and the force levels used to demonstrate the palpable abnormalities, these maps can record the results of clinical breast examination with a set of pressure distribution profiles and force sensor measurements due to detected lesion. By combining the knowledge of vision based, neural networks and tactile sensing technology; the TMD is integrated for the investigation of soft tissue interaction with tactile/force sensor, where the hard inclusion (breast cancer) can be characterized through neural network learning capability, instead of using simplified complex biomechanics model with many heuristic assumptions. These maps will serve as an objective documentation of palpable lesions for future comparative examinations. Preliminary results of simulated experiments and limited pre-clinical evaluations of the TMD prototype have tested this hypothesis and provided solid promising data showing the feasibility of the TMD in real clinical applications.

  6. Photoacoustic image patterns of breast carcinoma and comparisons with Magnetic Resonance Imaging and vascular stained histopathology

    Science.gov (United States)

    Heijblom, M.; Piras, D.; Brinkhuis, M.; van Hespen, J. C. G.; van den Engh, F. M.; van der Schaaf, M.; Klaase, J. M.; van Leeuwen, T. G.; Steenbergen, W.; Manohar, S.

    2015-07-01

    Photoacoustic (optoacoustic) imaging can visualize vasculature deep in tissue using the high contrast of hemoglobin to light, with the high-resolution possible with ultrasound detection. Since angiogenesis, one of the hallmarks of cancer, leads to increased vascularity, photoacoustics holds promise in imaging breast cancer as shown in proof-of-principle studies. Here for the first time, we investigate if there are specific photoacoustic appearances of breast malignancies which can be related to the tumor vascularity, using an upgraded research imaging system, the Twente Photoacoustic Mammoscope. In addition to comparisons with x-ray and ultrasound images, in subsets of cases the photoacoustic images were compared with MR images, and with vascular staining in histopathology. We were able to identify lesions in suspect breasts at the expected locations in 28 of 29 cases. We discovered generally three types of photoacoustic appearances reminiscent of contrast enhancement types reported in MR imaging of breast malignancies, and first insights were gained into the relationship with tumor vascularity.

  7. Image quality control of mammography equipment -Mammography System MX-300- of the Teachers Hospital of UNSA and dose measurement in breasts with radiographic films

    International Nuclear Information System (INIS)

    This work is part of medical imaging for the evaluation of quality. Will have an accredited breast phantom Rmi-156 that allows evaluating the image quality of mammography equipment and through a series of techniques and processes that will submit to mammography films we obtain characteristic curves, which allows to evaluate different parameters that will serve for our study. Images were acquired with different k Vp and m As of the equipment, also with different thicknesses of the breast phantom. Also we want to use the lowest possible dose for obtaining our images. In this paper we develop a simple protocol that aims to unify the conditions under which are acquired the images for later evaluation. By obtaining these characteristic curves demonstrate that the Kodak film is the most suitable for our study because it requires lower dose for obtaining our images. (Author)

  8. MR imaging of the reconstructed breast

    International Nuclear Information System (INIS)

    The etiology of pain is difficult to evaluate in a reconstructed breast because of capsular contracture and compression of tissue. MR images were obtained in 45 patients with a variety of pulse techniques. In hands, STIR (short inversion recovery) imaging was the most sensitive sequence. Suppression of the fat signal and increased contrast between normal and pathologic tissue, coupled with the synergistic effects of prolonged T1 and T2, were a major practical advantage. MR imaging can demonstrate recurrent tumor involving the chest wall, internal mammary nodes and rupture of the implant bag. The authors believe MR imaging can play a strong supplementary role in determining the etiology of pain in a postmastectomy patient

  9. Self-assembled levan nanoparticles for targeted breast cancer imaging.

    Science.gov (United States)

    Kim, Sun-Jung; Bae, Pan Kee; Chung, Bong Hyun

    2015-01-01

    We report on the targeted imaging of breast cancer using self-assembled levan nanoparticles. Indocyanine green (ICG) was encapsulated in levan nanoparticles via self-assembly. Levan-ICG nanoparticles were found to be successfully accumulated in breast cancer via specific interaction between fructose moieties in levan and overexpressed glucose transporter 5 in breast cancer cells. PMID:25383444

  10. Molecular breast imaging with gamma emitters.

    Science.gov (United States)

    Schillaci, O; Spanu, A; Danieli, R; Madeddu, G

    2013-12-01

    Following a diagnosis of breast cancer (BC), the early detection of local recurrence is important to define appropriate therapeutic strategies and increase the chances of a cure. In fact, despite major progress in surgical treatment, radiotherapy, and chemotherapy protocols, tumor recurrence is still a major problem. Moreover, the diagnosis of recurrence with conventional imaging methods can be difficult as a result of the presence of scar tissue. Molecular breast imaging (MBI) with gamma-ray emitting radiotracers may be very useful in this clinical setting, because it is not affected by the post-therapy morphologic changes. This review summarises the applications of 99mTc-sestamibi and 99mTc-tetrofosmin, the two most employed gamma emitter radiopharmaceuticals for MBI, in the diagnosis of local disease recurrence in patients with BC. The main limitation of MBI using conventional gamma-cameras is the low sensitivity for small BCs. The recent development of hybrid single photon emission computed tomography/computed tomography devices and especially of high-resolution specific breast cameras can improve the detection rate of sub-centimetric malignant lesions. Nevertheless, probably only the large availability of dedicated cameras will allow the clinical acceptance of MBI as useful complementary diagnostic technique in BC recurrence. The possible role of MBI with specific cameras in monitoring the local response of BC to neoadjuvant chemotherapy is also briefly discussed. PMID:24322791

  11. Medico-legal issues in breast imaging

    International Nuclear Information System (INIS)

    Aim: To identify medico-legal issues that occur in the diagnosis and radiological management of breast disease and to propose measures to reduce the risk of patient complaints and legal action in breast radiology and diagnosis. Materials and methods: Institutional review board approval was not applicable for this study. A retrospective study was undertaken and records of 120 medico-legal investigations over a 10 year period were examined. The reports were compiled by two consultant breast radiologists. Results: The mean age of the patients represented in this study was 48.3 years. The main complaint in this series was a delay in diagnosis (92%) followed by inappropriate or inadequate treatment (8%). 81% of cases were patients who had presented to the symptomatic clinic. The main presenting symptom was a palpable lump (65%). Substandard care was cited in 49/120 cases (41%). The mean average delay in diagnosis was 15.6 months. Of the cases cited as substandard care, 61% were considered the fault of the radiologist and 14% considered the fault of the breast surgeon. Of the cases where the radiologist was considered to be at fault, microcalcification was the most common mammographic sign to be missed or misinterpreted (12/26 cases, 46%). Conclusion: The most common complaint in this series was delay in diagnosis with microcalcification being the main mammographic sign that was either not seen or misinterpreted by the radiologist. Clear and precise written protocols are recommended for all breast imaging practice to ensure that medico-legal investigations will be greatly reduced.

  12. Medico-legal issues in breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Purushothaman, H.N., E-mail: hema.purushothaman@bartsandthelondon.nhs.uk [Department of Radiology, St Bartholomew' s Hospital, London (United Kingdom); Wilson, R. [Department of Radiology, The Royal Marsden Hospital, Sutton, Surrey (United Kingdom); Michell, M.J. [Department of Radiology, King' s College Hospital, London (United Kingdom)

    2012-07-15

    Aim: To identify medico-legal issues that occur in the diagnosis and radiological management of breast disease and to propose measures to reduce the risk of patient complaints and legal action in breast radiology and diagnosis. Materials and methods: Institutional review board approval was not applicable for this study. A retrospective study was undertaken and records of 120 medico-legal investigations over a 10 year period were examined. The reports were compiled by two consultant breast radiologists. Results: The mean age of the patients represented in this study was 48.3 years. The main complaint in this series was a delay in diagnosis (92%) followed by inappropriate or inadequate treatment (8%). 81% of cases were patients who had presented to the symptomatic clinic. The main presenting symptom was a palpable lump (65%). Substandard care was cited in 49/120 cases (41%). The mean average delay in diagnosis was 15.6 months. Of the cases cited as substandard care, 61% were considered the fault of the radiologist and 14% considered the fault of the breast surgeon. Of the cases where the radiologist was considered to be at fault, microcalcification was the most common mammographic sign to be missed or misinterpreted (12/26 cases, 46%). Conclusion: The most common complaint in this series was delay in diagnosis with microcalcification being the main mammographic sign that was either not seen or misinterpreted by the radiologist. Clear and precise written protocols are recommended for all breast imaging practice to ensure that medico-legal investigations will be greatly reduced.

  13. Improved MR breast images by contrast optimization using artificial intelligence

    International Nuclear Information System (INIS)

    The clinical relevance of MR imaging of the breast is mainly related to the modelity's ability to differentiate among normal, benign, and malignant tissue and to yield prognostic information. In addition to the MR imaging parameters, morphologic features of these images are calculated. Based on statistical information of a comprehensive, labeled image and knowledge of a data base system, a numerical classifier is deduced. The application of this classifier to all cases leads to estimations of specific tissue types for each pixel. The method is sufficiently sensitive for grading a recognized tissue class. In this manner images with optimal contrast appropriate to particular diagnostic requirements are generated. The discriminant power of each MR imaging parameter as well as of a combination of parameters can be determined objectively with respect to tissue discrimination

  14. Novel Fuzzy Technique for Cancer Detection in Noisy Breast Ultrasound Images

    Directory of Open Access Journals (Sweden)

    N. Alamelumangai

    2012-01-01

    Full Text Available Problem statement: Detecting tumor areas in breast Ultrasound (US images is a challenging task. The occurrence of benign areas in breast may result in false identification of malignant areas which may have serious outcome. Approach: The CAD system could act as a major function in the early detection of breast cancer and could decrease the death rate among women with breast cancer. This challenge was especially daunting in non homogenous noisy US Images where benign and malignant images were difficult to identify. The US images possess speckle noise which was its inherent property. This study was an attempt to reduce false alarm in Breast cancer detection using computationally efficient fuzzy based image clustering. Results: The proposed system was tested using images which was obtained from the famous American Cancer database for conducting experiments. We had compared the Noise Induced images with that of the De-speckled images and found that the de-speckled images yeild a better image for diagnosis based. Later the image was clustered based on Fuzzy C-Means based clustering technique to identify the cancerous cells. Conclusion: An efficient method is suggested in this study which assist in diagnosing the cancer cells. The Fuzzy C-Means clustering system identifies various important artifacts, such as cyst, tumor and micro calcifications. The challenge in this system is the speckle noise. It can be extended to FCM class 2 non-homogeneous images.

  15. (Re) Imaging the breast: An analysis of a cultural obsession

    International Nuclear Information System (INIS)

    This article is a brief resume of the work done for an academic thesis to explore any possible relationship between historical images of the female breast, and the subsequent development of positive or negative self-imaging for modern women. Using historical images of the breast from pre-Christian times to the pre ent, the many uses of breast imaging are explored. The research was conducted by the use of eleven interviews, as well as survey forms that targeted two different groups of women. One survey was given to the general female population, and the other targeted mammographic technologists. The findings were varied and provided an interesting examination of the ambiguity inherent in women's perception of their breasts and the breasts of other women. The research clearly indicated a need for farther study involving mammographic technologists. Radiographers combine the requirements of the job with their personal viewpoints, which have been impacted by both past and present breast imaging. (author)

  16. TH-A-18A-01: Innovation in Clinical Breast Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Liu, B [Massachusetts General Hospital, Boston, MA (United States); Yang, K [University of Oklahoma, Oklahomoa City, OK (United States); Yaffe, M [University Toronto, Toronto, ON (Canada); Chen, J [GE/U-Systems, Sunnyvale, CA (United States)

    2014-06-15

    Several novel modalities have been or are on the verge of being introduced into the breast imaging clinic. These include tomosynthesis imaging, dedicated breast CT, contrast-enhanced digital mammography, and automated breast ultrasound, all of which are covered in this course. Tomosynthesis and dedicated breast CT address the problem of tissue superimposition that limits mammography screening performance, by improved or full resolution of the 3D breast morphology. Contrast-enhanced digital mammography provides functional information that allows for visualization of tumor angiogenesis. 3D breast ultrasound has high sensitivity for tumor detection in dense breasts, but the imaging exam was traditionally performed by radiologists. In automated breast ultrasound, the scan is performed in an automated fashion, making for a more practical imaging tool, that is now used as an adjunct to digital mammography in breast cancer screening. This course will provide medical physicists with an in-depth understanding of the imaging physics of each of these four novel imaging techniques, as well as the rationale and implementation of QC procedures. Further, basic clinical applications and work flow issues will be discussed. Learning Objectives: To be able to describe the underlying physical and physiological principles of each imaging technique, and to understand the corresponding imaging acquisition process. To be able to describe the critical system components and their performance requirements. To understand the rationale and implementation of quality control procedures, as well as regulatory requirements for systems with FDA approval. To learn about clinical applications and understand risks and benefits/strength and weakness of each modality in terms of clinical breast imaging.

  17. A glass compensator filter to improve breast image quality in radiation therapy simulation

    International Nuclear Information System (INIS)

    Purpose: To improve the image quality of simulation films in tangential radiotherapy for breast cancer, we have designed a new compensator filter for the variation of breast contour using high-density-glass material. Methods and Materials: The measurements and analyses of the body contour were done using CT scans, taken in the treatment position, of 20 breast cancer patients. The maximum tissue deficit that needed to be compensated for was 8 cm, and the authors fabricated the compensator system using high-density-glass material to maintain transparency. The glass compensator can be attached to the accessory mount of the simulator head and its position can be easily adjusted according to breast shape and position. The image qualities of simulation films taken with and without the glass compensator in tangential breast radiotherapy field were compared and the film densitometry was performed using the humanoid phantom. Results: Using this compensator system, the overall image quality improved, resulting in enhanced contrast and resolution of the breast simulation image. The delineator wires for the beam margins were also well depicted, and the surgical clips within the breast tissue can be easily demonstrated. The film densitometry resulted in much less saturation over the breast tissue when using the glass compensator. Conclusion: Using the glass compensator system, the geographical miss may be reduced with the virtue of the improved image quality

  18. High resolution PET breast imager with improved detection efficiency

    Science.gov (United States)

    Majewski, Stanislaw

    2010-06-08

    A highly efficient PET breast imager for detecting lesions in the entire breast including those located close to the patient's chest wall. The breast imager includes a ring of imaging modules surrounding the imaged breast. Each imaging module includes a slant imaging light guide inserted between a gamma radiation sensor and a photodetector. The slant light guide permits the gamma radiation sensors to be placed in close proximity to the skin of the chest wall thereby extending the sensitive region of the imager to the base of the breast. Several types of photodetectors are proposed for use in the detector modules, with compact silicon photomultipliers as the preferred choice, due to its high compactness. The geometry of the detector heads and the arrangement of the detector ring significantly reduce dead regions thereby improving detection efficiency for lesions located close to the chest wall.

  19. Fast 3-d tomographic microwave imaging for breast cancer detection.

    Science.gov (United States)

    Grzegorczyk, Tomasz M; Meaney, Paul M; Kaufman, Peter A; diFlorio-Alexander, Roberta M; Paulsen, Keith D

    2012-08-01

    Microwave breast imaging (using electromagnetic waves of frequencies around 1 GHz) has mostly remained at the research level for the past decade, gaining little clinical acceptance. The major hurdles limiting patient use are both at the hardware level (challenges in collecting accurate and noncorrupted data) and software level (often plagued by unrealistic reconstruction times in the tens of hours). In this paper we report improvements that address both issues. First, the hardware is able to measure signals down to levels compatible with sub-centimeter image resolution while keeping an exam time under 2 min. Second, the software overcomes the enormous time burden and produces similarly accurate images in less than 20 min. The combination of the new hardware and software allows us to produce and report here the first clinical 3-D microwave tomographic images of the breast. Two clinical examples are selected out of 400+ exams conducted at the Dartmouth Hitchcock Medical Center (Lebanon, NH). The first example demonstrates the potential usefulness of our system for breast cancer screening while the second example focuses on therapy monitoring. PMID:22562726

  20. Positive predictive values of Breast Imaging Reporting and Data System (BI-RADS® categories 3, 4 and 5 in breast lesions submitted to percutaneous biopsy

    Directory of Open Access Journals (Sweden)

    Gustavo Machado Badan

    2013-07-01

    Full Text Available Objective To evaluate the BI-RADS as a predictive factor of suspicion for malignancy in breast lesions by correlating radiological with histological results and calculating the positive predictive value for categories 3, 4 and 5 in a breast cancer reference center in the city of São Paulo. Materials and Methods Retrospective, analytical and cross-sectional study including 725 patients with mammographic and/or sonographic findings classified as BI-RADS categories 3, 4 and 5 who were referred to the authors' institution to undergo percutaneous biopsy. The tests results were reviewed and the positive predictive value was calculated by means of a specific mathematical equation. Results Positive predictive values found for categories 3, 4 and 5 were respectively the following: 0.74%, 33.08% and 92.95%, for cases submitted to ultrasound-guided biopsy, and 0.00%, 14.90% and 100% for cases submitted to stereotactic biopsy. Conclusion The present study demonstrated high suspicion for malignancy in lesions classified as category 5 and low risk for category 3. As regards category 4, the need for systematic biopsies was observed.

  1. Breast imaging reporting and data system (BI-RADS) US lexicon and final assessment category for solid breast masses: the rates of inter-and intraobserver agreement

    International Nuclear Information System (INIS)

    To evaluate the rates of inter-and intraobserver agreement of the BI-RADS US lexicon. Two radiologists reviewed 60 sonograms of solid breast masses to evaluate interobserver agreement. After four weeks, the radiologists reinterpreted the series to evaluate the intraobserver agreement. The radiologists described shape, orientation, margin, lesion boundary, echo pattern, posterior acoustic features and microcalcifications. Final assessment categories and management plans were suggested for each case. The rates of inter-and intraobserver agreements were measured by the use of kappa statistics. Interobserver agreement ranged from the highest for orientation (κ = 0.65) and shape (κ = 0.61) to the lowest for posterior acoustic features (κ = 0.42). For the final assessment categories (κ = 0.46) and management (κ = 0.49), interobserver agreement were moderate. Intraobserver agreement ranged from the highest for microcalcifications in mass (κ = 0.90, 0.82) and orientation (κ 0.87, 0.83) and the lowest for echo patterns (κ = 0.62, 0.57) and posterior acoustic features (κ = 0.59, 0.65). In the final assessment category and management, intraobserver agreements were substantial or nearly complete (κ = 0.65-0.83). There were variable raged inter-and intraobserver agreements in the description of the BI-RADS US lexicon of solid breast masses. Among them, margin and lesion boundary showed lower agreements. A modification of the BI-RADS US lexicon with more detailed guidelines, followed by continuous education, are suggested

  2. Breast imaging technology: Probing physiology and molecular function using optical imaging - applications to breast cancer

    International Nuclear Information System (INIS)

    The present review addresses the capacity of optical imaging to resolve functional and molecular characteristics of breast cancer. We focus on recent developments in optical imaging that allow three-dimensional reconstruction of optical signatures in the human breast using diffuse optical tomography (DOT). These technologic advances allow the noninvasive, in vivo imaging and quantification of oxygenated and deoxygenated hemoglobin and of contrast agents that target the physiologic and molecular functions of tumors. Hence, malignancy differentiation can be based on a novel set of functional features that are complementary to current radiologic imaging methods. These features could enhance diagnostic accuracy, lower the current state-of-the-art detection limits, and play a vital role in therapeutic strategy and monitoring

  3. The imaging features of MACROLANETM in breast augmentation

    International Nuclear Information System (INIS)

    MacrolaneTM is an injectable, biocompatible, soft-tissue filler that has been available in the UK since 2008 and is promoted for use in breast augmentation. There are few data available on the long-term effects of this relatively new product and concerns have been raised about the implications for breast imaging, in particular breast screening. In this context we present a spectrum of imaging appearances and complications encountered to date.

  4. Preliminary images from an adaptive imaging system.

    Science.gov (United States)

    Griffiths, J A; Metaxas, M G; Pani, S; Schulerud, H; Esbrand, C; Royle, G J; Price, B; Rokvic, T; Longo, R; Asimidis, A; Bletsas, E; Cavouras, D; Fant, A; Gasiorek, P; Georgiou, H; Hall, G; Jones, J; Leaver, J; Li, G; Machin, D; Manthos, N; Matheson, J; Noy, M; Ostby, J M; Psomadellis, F; van der Stelt, P F; Theodoridis, S; Triantis, F; Turchetta, R; Venanzi, C; Speller, R D

    2008-06-01

    I-ImaS (Intelligent Imaging Sensors) is a European project aiming to produce real-time adaptive X-ray imaging systems using Monolithic Active Pixel Sensors (MAPS) to create images with maximum diagnostic information within given dose constraints. Initial systems concentrate on mammography and cephalography. In our system, the exposure in each image region is optimised and the beam intensity is a function of tissue thickness and attenuation, and also of local physical and statistical parameters in the image. Using a linear array of detectors, the system will perform on-line analysis of the image during the scan, followed by optimisation of the X-ray intensity to obtain the maximum diagnostic information from the region of interest while minimising exposure of diagnostically less important regions. This paper presents preliminary images obtained with a small area CMOS detector developed for this application. Wedge systems were used to modulate the beam intensity during breast and dental imaging using suitable X-ray spectra. The sensitive imaging area of the sensor is 512 x 32 pixels 32 x 32 microm(2) in size. The sensors' X-ray sensitivity was increased by coupling to a structured CsI(Tl) scintillator. In order to develop the I-ImaS prototype, the on-line data analysis and data acquisition control are based on custom-developed electronics using multiple FPGAs. Images of both breast tissues and jaw samples were acquired and different exposure optimisation algorithms applied. Results are very promising since the average dose has been reduced to around 60% of the dose delivered by conventional imaging systems without decrease in the visibility of details. PMID:18291697

  5. Fusion Imaging of MRI and US for Evaluating Breast Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Jung Min; Moon, Woo Kyung [Seoul National University Hospital, Seoul (Korea, Republic of)

    2011-09-15

    Second look US evaluation is frequently performed for assessing incidentally discovered enhancing lesions seen on MRI. However, the success of the examination depends on the experience and technique of the operator. Sonographic identification of an MRI incidentally detected lesion is difficult because the patient's body is positioned differently during sonography than it is during MRI. Fusion imaging of MRI and US has recently been developed, for which a position tracking system is coordinated with a magnetic sensor. This system synchronizes an ultrasound image and the MR image with multi-planar reconstruction (MPR) of the same area in real time. The purpose of this study was to evaluate the usefulness of fusion imaging of MR and US for evaluating breast lesions

  6. Processed images in human perception: A case study in ultrasound breast imaging

    International Nuclear Information System (INIS)

    Two main research efforts in early detection of breast cancer include the development of software tools to assist radiologists in identifying abnormalities and the development of training tools to enhance their skills. Medical image analysis systems, widely known as Computer-Aided Diagnosis (CADx) systems, play an important role in this respect. Often it is important to determine whether there is a benefit in including computer-processed images in the development of such software tools. In this paper, we investigate the effects of computer-processed images in improving human performance in ultrasound breast cancer detection (a perceptual task) and classification (a cognitive task). A survey was conducted on a group of expert radiologists and a group of non-radiologists. In our experiments, random test images from a large database of ultrasound images were presented to subjects. In order to gather appropriate formal feedback, questionnaires were prepared to comment on random selections of original images only, and on image pairs consisting of original images displayed alongside computer-processed images. We critically compare and contrast the performance of the two groups according to perceptual and cognitive tasks. From a Receiver Operating Curve (ROC) analysis, we conclude that the provision of computer-processed images alongside the original ultrasound images, significantly improve the perceptual tasks of non-radiologists but only marginal improvements are shown in the perceptual and cognitive tasks of the group of expert radiologists.

  7. Magnetic resonance imaging of breast. Actual technique and indications

    International Nuclear Information System (INIS)

    Optimal breast MRI protocols are required using dedicated breast coils, high spatial resolution dynamic sequences (morphologic criteria are significantly more accurate than kinetic criteria) and bolus injection of contrast medium. Any abnormal MR enhancement must be described using BI-RADSMRI lexicon. Main indications of breast MRI are: suspicion of intra-capsular rupture (silicone implants), local relapse in a treated breast, search for breast cancer (metastatic axillary lymph nodes), locals staging of a breast cancer (dense breasts), follow-up of cancer under neoadjuvant chemotherapy, and screening in high-risk patients (gene mutation background). MRI is also useful for patients with unresolved problems at standard imaging (high negative predictive value of MRI). In patients with breast cancer, it is important to underline the need for radiologists to work with the multidisciplinary team and the ability to perform MR-guided biopsies for additional suspicious enhancements. (author)

  8. The current status of imaging diagnosis of breast cancer

    International Nuclear Information System (INIS)

    In recent years, the incidence and the mortality rate of female breast cancer in our country is increasing, Early diagnosis of breast cancer is particularly important. Precious preoperative staging in the breast cancer is advantageous for the treatment planning. Evaluating the efficacy of chemotherapy is beneficial for adjusting the follow-up plan. Imaging examination has become an important role in breast cancer management. At present, commonly used equipment include mammography, ultrasound, CT, and MRI, etc. This article reviews the present study status of these tools in diagnosis of breast cancer. A reasonable and effective choice of those tools can facilitate clinic diagnosis and treatment. (authors)

  9. Imaging probe for breast cancer localization

    International Nuclear Information System (INIS)

    High spatial resolution, small Field Of View (FOV), fully portable scintillation cameras are lower cost and obviously lower weight than large FOV, not transportable Anger gamma cameras. Portable cameras allow easy transfer of the detector, thus of radioisotope imaging, where the bioptical procedure takes place. In this paper we describe a preliminary experience on radionuclide Breast Cancer (BC) imaging with a 22.8x22.8 mm2 FOV minicamera, already used by our group for sentinel node detection with the name of Imaging Probe (IP). In this work IP BC detection was performed with the aim of guiding biopsy, in particular open biopsy, or to help or modify fine needle or needle addressing when main driving method was echography or digital radiography. The IP prototype weight was about 1 kg. This small scintillation camera is based on the compact Position Sensitive Photomultiplier Tube Hamamatsu R7600-00-C8, coupled to a CsI(Tl) scintillation array 2.6x2.6x5.0 mm3 crystal-pixel size. Spatial resolution of the IP was 2.5 mm Full-Width at Half-Maximum at laboratory tests. IP was provided with acquisition software allowing quick change of pixels number on the computer acquisition frame and an on-line image-smoothing program. Both these programs were developed in order to allow nuclear physicians to quickly get target source when the patient was anesthetized in the operator room, with sterile conditions. 99mTc Sestamibi (MIBI) was injected at the dose of 740 MBq 1 h before imaging and biopsy to 14 patients with suspicious or known BC. Scintigraphic images were acquired before and after biopsy in each patient. Operator was allowed to take into account scintigraphic images as well as previously performed X-ray mammograms and echographies. High-resolution IP images were able to guide biopsy toward cancer or washout zones of the cancer, that are thought to be chemoresistant in 7 patients out of 10. Four patients, in whom IP and MIBI were not able to guide biopsy, did not show

  10. Three-dimensional Imaging and Simulation in Breast Augmentation: What Is the Current State of the Art?

    Science.gov (United States)

    Epstein, Mark D; Scheflan, Michael

    2015-10-01

    This article discusses perception of three-dimensional objects and binocular vision. High-resolution three-dimensional images of the breast can be captured using a camera system consisting of 3 separate stereoscopic pairs of digital cameras. The images (surfaces) are then joined to form a 220° surface of the torso, including the breasts. The images can be rotated freely in space. Simulation of augmentation with or without mastopexy is presented. Three-dimensional imaging and computer simulation of breast augmentation has become an emerging technology in many breast augmentation practices. This technology can be integrated in different ways into the consultation and informed consent process. PMID:26408435

  11. Extra-mammary findings detected on breast magnetic resonance imaging: A pictorial Essay

    International Nuclear Information System (INIS)

    Magnetic resonance imaging (MRI) of the breast is used for various indications. Contrary to computed tomography as a staging tool, breast MRI focuses on the breast parenchyma and axilla. In spite of narrow field of view, many structures such as the anterior portion of the lungs, mediastinum, bony structures and the liver are included which should not be neglected because the abnormalities detected on the above structures may influence the staging and provide a clue to systemic metastasis, which results in the change of treatment strategy. The purpose of this pictorial essay was to review the unexpected extra-mammary findings seen on the preoperative breast MRI.

  12. Extra-mammary findings detected on breast magnetic resonance imaging: A pictorial Essay

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Hee Jung; Choi, Ji Soo; Ko, Kyung Ran [National Cancer Center, Goyang (Korea, Republic of)

    2014-08-15

    Magnetic resonance imaging (MRI) of the breast is used for various indications. Contrary to computed tomography as a staging tool, breast MRI focuses on the breast parenchyma and axilla. In spite of narrow field of view, many structures such as the anterior portion of the lungs, mediastinum, bony structures and the liver are included which should not be neglected because the abnormalities detected on the above structures may influence the staging and provide a clue to systemic metastasis, which results in the change of treatment strategy. The purpose of this pictorial essay was to review the unexpected extra-mammary findings seen on the preoperative breast MRI.

  13. Positive predictive value of additional synchronous breast lesions in whole-breast ultrasonography at the diagnosis of breast cancer: clinical and imaging factors

    International Nuclear Information System (INIS)

    To evaluate the positive predictive value (PPV) of bilateral whole-breast ultrasonography (BWBU) for detection of synchronous breast lesions on initial diagnosis of breast cancer and evaluate factors affecting the PPV of BWBU according to varying clinicoimaging factors. A total of 75 patients who had synchronous lesions with pathologic confirmation at the initial diagnosis of breast cancer during January 2007 and December 2007 were included. The clinical factors of the patients were evaluated. One observer retrospectively reviewed the imaging studies of the index breast cancer lesion and the synchronous lesion. The PPV for additional biopsy was calculated for BWBU and various clinical and imaging factors affecting the PPV for BWBU were evaluated. The overall PPV for additional biopsy was 25.7% (18 of 70). The PPV for synchronous lesions detected both on mammography and BWBU, and detected only on BWBU, was 76.9% (10 of 13) and 14.3% (7 of 49), respectively. There was no clinical factor affecting the PPV for BWBU. Among the imaging factors, ipsilateral location of the synchronous lesion to the index lesion (P=0.06) showed a marginal statistically significant correlation with malignancy in the synchronous breast lesion. A mass with calcification on mammography presentation (P<0.01), presence of calcification among the ultrasonography findings (P<0.01), and high Breast Imaging Reporting and Data System final assessment (P<0.01) were imaging factors that were associated with malignancy in the additional synchronous lesion. BWBU can detect additional synchronous malignancy at the diagnosis of breast cancer with a relatively high PPV, especially when mammography findings are correlated with ultrasonographic findings.

  14. Positive predictive value of additional synchronous breast lesions in whole-breast ultrasonography at the diagnosis of breast cancer: clinical and imaging factors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ah Hyun; Kim, Min Jung; Kim, Eun Kyung; Moon, Hee Jung [Dept. of Radiology, Research Institute of Radiological Science, Seoul (Korea, Republic of); Park, Hee Jung [Dept. of Surgery, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-10-15

    To evaluate the positive predictive value (PPV) of bilateral whole-breast ultrasonography (BWBU) for detection of synchronous breast lesions on initial diagnosis of breast cancer and evaluate factors affecting the PPV of BWBU according to varying clinicoimaging factors. A total of 75 patients who had synchronous lesions with pathologic confirmation at the initial diagnosis of breast cancer during January 2007 and December 2007 were included. The clinical factors of the patients were evaluated. One observer retrospectively reviewed the imaging studies of the index breast cancer lesion and the synchronous lesion. The PPV for additional biopsy was calculated for BWBU and various clinical and imaging factors affecting the PPV for BWBU were evaluated. The overall PPV for additional biopsy was 25.7% (18 of 70). The PPV for synchronous lesions detected both on mammography and BWBU, and detected only on BWBU, was 76.9% (10 of 13) and 14.3% (7 of 49), respectively. There was no clinical factor affecting the PPV for BWBU. Among the imaging factors, ipsilateral location of the synchronous lesion to the index lesion (P=0.06) showed a marginal statistically significant correlation with malignancy in the synchronous breast lesion. A mass with calcification on mammography presentation (P<0.01), presence of calcification among the ultrasonography findings (P<0.01), and high Breast Imaging Reporting and Data System final assessment (P<0.01) were imaging factors that were associated with malignancy in the additional synchronous lesion. BWBU can detect additional synchronous malignancy at the diagnosis of breast cancer with a relatively high PPV, especially when mammography findings are correlated with ultrasonographic findings.

  15. MR imaging of the augmented breast

    International Nuclear Information System (INIS)

    Mammographic evaluation of the augmented breast is challenging, since breast implants obscure significant amount of breast tissue while diminishing the effect of compression. Posttherapeutic scarring can make mammographic interpretation even more difficult. MRI has thus evolved into the modality of choice for diagnosing implant complications as well as detection of primary or recurrent breast cancer in these patient population. The present article attemps to give an overview of the MR findings of different breast augmentation and reconstruction techniques, i. e. prosthetic breast implants, breast reconstruction with autogenous tissue, free silicone injections and fat grafts, and their complications. (orig.)

  16. Including Antenna Models in Microwave Imaging for Breast-Cancer Screening

    DEFF Research Database (Denmark)

    Rubæk, Tonny; Meincke, Peter

    2006-01-01

    Microwave imaging is emerging as a tool for screening for breast cancer, but the lack of methods for including the characteristics of the antennas of the imaging systems in the imaging algorithms limits their performance. In this paper, a method for incorporating the full antenna characteristics...

  17. Diagnosis of breast implant rupture using magnetic resonance imaging

    International Nuclear Information System (INIS)

    At least 20,000 Norwegian woman have silicone breast implants, either for breast augmentation or for reconstruction. One of the complications associated with breast implants is rupture of the implants. Magnetic resonance imaging (MRI) has been shown to be the most accurate imaging modality for evaluating the integrity of breast implants. Recognition of the different types of implants and the appearance of normal implants on MRI is very important for distinguishing these from intracapsular and extracapsular ruptures. Examples are shown of MRI findings in normal and ruptured implants. 16 refs., 6 figs

  18. Primary Neuroendocrine Tumor of the Breast: Imaging Features

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Eun Deok [Department of Clinical Pathology, Uijeongbu St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu 480-717 (Korea, Republic of); Kim, Min Kyun [Department of Radiology, Uijeongbu St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu 480-717 (Korea, Republic of); Kim, Jeong Soo [Department of Surgery, Uijeongbu St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu 480-717 (Korea, Republic of); Whang, In Yong [Department of Radiology, Uijeongbu St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu 480-717 (Korea, Republic of)

    2013-07-01

    Focal neuroendocrine differentiation can be found in diverse histological types of breast tumors. However, the term, neuroendocrine breast tumor, indicates the diffuse expression of neuroendocrine markers in more than 50% of the tumor cell population. The imaging features of neuroendocrine breast tumor have not been accurately described due to extreme rarity of this tumor type. We present a case of a pathologically confirmed, primary neuroendocrine breast tumor in a 42-year-old woman, with imaging findings difficult to be differentiated from that of invasive ductal carcinoma.

  19. A Dataset for Breast Cancer Histopathological Image Classification.

    Science.gov (United States)

    Spanhol, Fabio A; Oliveira, Luiz S; Petitjean, Caroline; Heutte, Laurent

    2016-07-01

    Today, medical image analysis papers require solid experiments to prove the usefulness of proposed methods. However, experiments are often performed on data selected by the researchers, which may come from different institutions, scanners, and populations. Different evaluation measures may be used, making it difficult to compare the methods. In this paper, we introduce a dataset of 7909 breast cancer histopathology images acquired on 82 patients, which is now publicly available from http://web.inf.ufpr.br/vri/breast-cancer-database. The dataset includes both benign and malignant images. The task associated with this dataset is the automated classification of these images in two classes, which would be a valuable computer-aided diagnosis tool for the clinician. In order to assess the difficulty of this task, we show some preliminary results obtained with state-of-the-art image classification systems. The accuracy ranges from 80% to 85%, showing room for improvement is left. By providing this dataset and a standardized evaluation protocol to the scientific community, we hope to gather researchers in both the medical and the machine learning field to advance toward this clinical application. PMID:26540668

  20. Dynamic optical breast imaging: A novel technique to detect and characterize tumor vessels

    International Nuclear Information System (INIS)

    Purpose: To prospectively determine the diagnostic accuracy of optical absorption imaging in patients with Breast Imaging Reporting and Data System (BI-RADS) 3-5 breast lesions. Materials and methods: Forty-six patients with BI-RADS classification 3 (11%), 4 (44%) or 5 (44%) lesions, underwent a novel optical imaging examination using red light to illuminate the breast. Pressure was applied on the breast, and time-dependent curves of light absorption were recorded. Curves that consistently increased or decreased over time were classified as suspicious for malignancy. All patients underwent a core or surgical biopsy. Results: Optical mammography showed a statistical difference in numbers of suspect pixels between benign (N = 12) and malignant (N = 35) lesions (respectively 1325 vs. 3170, P = 0.002). In this population, optical imaging had a sensitivity of 74%, specificity of 92%, and diagnostic accuracy of 79%. The optical signal did not vary according to any other parameter including breast size or density, age, hormonal status or histological type of lesions. Conclusion: Optical imaging is a low-cost, non-invasive technique, yielding physiological information dependent on breast blood volume and oxygenation. It appears to have a good potential for discriminating benign from malignant lesions. Further studies are warranted to define its potential role in breast cancer imaging

  1. Ultrasound imaging of breast tumor perfusion and neovascular morphology.

    Science.gov (United States)

    Hoyt, Kenneth; Umphrey, Heidi; Lockhart, Mark; Robbin, Michelle; Forero-Torres, Andres

    2015-09-01

    A novel image processing strategy is detailed for simultaneous measurement of tumor perfusion and neovascular morphology parameters from a sequence of dynamic contrast-enhanced ultrasound (DCE-US) images. After normalization and tumor segmentation, a global time-intensity curve describing contrast agent flow was analyzed to derive surrogate measures of tumor perfusion (i.e., peak intensity, time-to-peak intensity, area under the curve, wash-in rate, wash-out rate). A maximum intensity image was generated from these same segmented image sequences, and each vascular component was skeletonized via a thinning algorithm. This skeletonized data set and collection of vessel segments were then investigated to extract parameters related to the neovascular network and physical architecture (i.e., vessel-to-tissue ratio, number of bifurcations, vessel count, average vessel length and tortuosity). An efficient computation of local perfusion parameters was also introduced and operated by averaging time-intensity curve data over each individual neovascular segment. Each skeletonized neovascular segment was then color-coded by these local measures to produce a parametric map detailing spatial properties of tumor perfusion. Longitudinal DCE-US image data sets were collected in six patients diagnosed with invasive breast cancer using a Philips iU22 ultrasound system equipped with a L9-3 transducer and Definity contrast agent. Patients were imaged using US before and after contrast agent dosing at baseline and again at weeks 6, 12, 18 and 24 after treatment started. Preliminary clinical results suggested that breast tumor response to neoadjuvant chemotherapy may be associated with temporal and spatial changes in DCE-US-derived parametric measures of tumor perfusion. Moreover, changes in neovascular morphology parametric measures may also help identify any breast tumor response (or lack thereof) to systemic treatment. Breast cancer management from early detection to therapeutic

  2. Imaging recognition of multidrug resistance in human breast tumors using {sup 99m}Tc-labeled monocationic agents and a high-resolution stationary SPECT system

    Energy Technology Data Exchange (ETDEWEB)

    Liu Zhonglin E-mail: zliu@radiology.arizona.edu; Stevenson, Gail D.; Barrett, Harrison H.; Kastis, George A.; Bettan, Michael; Furenlid, Lars R.; Wilson, Donald W.; Woolfenden, James M

    2004-01-01

    Imaging recognition of multidrug-resistance by {sup 99m}Tc-labeled sestamibi, tetrofosmin and furifosmin in mice bearing human breast tumors was evaluated using a high-resolution SPECT, FASTSPECT. Imaging results showed that the washout rates in drug-resistant MCF7/D40 tumors were significantly greater than that in drug-sensitive MCF7/S tumors. Furifosmin exhibited greater washout from both MCF7/S and MCF7/D40 than sestamibi, while tetrofosmin washout was greater than sestamibi in MCF7/D40 only. Feasibility of the monocationic agents for characterizing MDR expression was well clarified with FASTSPECT imaging.

  3. Breast Imaging in Evaluation of Breast Cancer: Radiologist’s Point of View

    Directory of Open Access Journals (Sweden)

    Nahid Sedighi

    2010-05-01

    Full Text Available In every breast imaging, the radiologist confronts these questions:"n1. Finding the lesion"n2. Is the lesion real?"n3. Where the pathology lies"n4. What the lesion is "n5. What should be done about it?"nThe major objective in breast imaging is the detection of breast cancers at a small size and early stage in an effort to reduce mortality."nSome conditions limit evaluation of breast cancer imaging."nWhen additional mammographic views or ultrasound are unable to triangulate the location of a lesion, computed tomography can be very helpful for locating lesions three dimensionally. MRI with and without contrast is the other modality for evaluation of problematic cases or ambiguous findings in other modalities."nImplants present a problem for breast imaging in that they may prevent optimal visualization of the tissues."nA focal asymmetric density may merely represent an island of breast tissue. DCIS, with or without calcification, and metastatic axillary lymph nodes in a normal mammogram are some of the problematic cases of breast cancer."nThis presentation is expected to include real cases of breast cancer with the above-mentioned problems or unusual manifestations, which are resolved by a combination of different imaging modalities.    

  4. Characterization of the homogeneous tissue mixture approximation in breast imaging dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Sechopoulos, Ioannis; Bliznakova, Kristina; Qin Xulei; Fei Baowei; Feng, Steve Si Jia [Department of Radiology and Imaging Sciences and Winship Cancer Institute, Emory University School of Medicine, 1701 Upper Gate Drive Northeast, Suite 5018, Atlanta, Georgia 30322 (United States); Department of Medical Physics, University of Patras School of Health Sciences, 26500 Rio-Patras (Greece); Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1701 Upper Gate Drive Northeast, Suite 5018, Atlanta, Georgia 30322 (United States); Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1701 Upper Gate Drive Northeast, Suite 5018, Atlanta, Georgia 30322 and Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgia 30322 (United States)

    2012-08-15

    Purpose: To compare the estimate of normalized glandular dose in mammography and breast CT imaging obtained using the actual glandular tissue distribution in the breast to that obtained using the homogeneous tissue mixture approximation. Methods: Twenty volumetric images of patient breasts were acquired with a dedicated breast CT prototype system and the voxels in the breast CT images were automatically classified into skin, adipose, and glandular tissue. The breasts in the classified images underwent simulated mechanical compression to mimic the conditions present during mammographic acquisition. The compressed thickness for each breast was set to that achieved during each patient's last screening cranio-caudal (CC) acquisition. The volumetric glandular density of each breast was computed using both the compressed and uncompressed classified images, and additional images were created in which all voxels representing adipose and glandular tissue were replaced by a homogeneous mixture of these two tissues in a proportion corresponding to each breast's volumetric glandular density. All four breast images (compressed and uncompressed; heterogeneous and homogeneous tissue) were input into Monte Carlo simulations to estimate the normalized glandular dose during mammography (compressed breasts) and dedicated breast CT (uncompressed breasts). For the mammography simulations the x-ray spectra used was that used during each patient's last screening CC acquisition. For the breast CT simulations, two x-ray spectra were used, corresponding to the x-ray spectra with the lowest and highest energies currently being used in dedicated breast CT prototype systems under clinical investigation. The resulting normalized glandular dose for the heterogeneous and homogeneous versions of each breast for each modality was compared. Results: For mammography, the normalized glandular dose based on the homogeneous tissue approximation was, on average, 27% higher than that

  5. Advances in Optical Spectroscopy and Imaging of Breast Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Demos, S; Vogel, A J; Gandjbakhche, A H

    2006-01-03

    A review is presented of recent advances in optical imaging and spectroscopy and the use of light for addressing breast cancer issues. Spectroscopic techniques offer the means to characterize tissue components and obtain functional information in real time. Three-dimensional optical imaging of the breast using various illumination and signal collection schemes in combination with image reconstruction algorithms may provide a new tool for cancer detection and monitoring of treatment.

  6. A high-resolution photon-counting breast CT system with tensor-framelet based iterative image reconstruction for radiation dose reduction

    International Nuclear Information System (INIS)

    Both computer simulations and experimental phantom studies were carried out to investigate the radiation dose reduction with tensor framelet based iterative image reconstruction (TFIR) for a dedicated high-resolution spectral breast computed tomography (CT) based on a silicon strip photon-counting detector. The simulation was performed with a 10 cm-diameter water phantom including three contrast materials (polyethylene, 8 mg ml−1 iodine and B-100 bone-equivalent plastic). In the experimental study, the data were acquired with a 1.3 cm-diameter polymethylmethacrylate (PMMA) phantom containing iodine in three concentrations (8, 16 and 32 mg ml−1) at various radiation doses (1.2, 2.4 and 3.6 mGy) and then CT images were reconstructed using the filtered-back-projection (FBP) technique and the TFIR technique, respectively. The image quality between these two techniques was evaluated by the quantitative analysis on contrast-to-noise ratio (CNR) and spatial resolution that was evaluated using the task-based modulation transfer function (MTF). Both the simulation and experimental results indicated that the task-based MTF obtained from TFIR reconstruction with one-third of the radiation dose was comparable to that from the FBP reconstruction for low contrast target. For high contrast target, the TFIR was substantially superior to the FBP reconstruction in terms of spatial resolution. In addition, TFIR was able to achieve a factor of 1.6–1.8 increase in CNR, depending on the target contrast level. This study demonstrates that the TFIR can reduce the required radiation dose by a factor of two-thirds for a CT image reconstruction compared to the FBP technique. It achieves much better CNR and spatial resolution for high contrast target in addition to retaining similar spatial resolution for low contrast target. This TFIR technique has been implemented with a graphic processing unit system and it takes approximately 10 s to reconstruct a single-slice CT

  7. Breast CT image simulation framework for optimisation of lesion visualisation

    OpenAIRE

    Diaz, O; Elangovan, P.; Wells, K.; Enshaeifar, S; Veale, MC; Wilson, MD; Seller, P; Cernik, R; Pani, S.

    2013-01-01

    Although X-ray mammography is the gold standard technique for breast cancer detection, it suffers from limitations due to tissue superposition which could either obscure or mimic a breast lesion. Dedicated breast computed-tomography (BrCT) represents an alternative technology with the potential to overcome these limitations. However, this technology is still under investigation in order to study and improve certain parameters (e.g. dose, scattered radiation, etc.). In this work, an image simu...

  8. Imaging methods for the local lymphatic system of the axilla in early breast cancer in patients qualified for sentinel lymph node biopsy.

    Science.gov (United States)

    Nowikiewicz, Tomasz; Kurylcio, Andrzej; Polkowski, Wojciech; Zegarski, Wojciech

    2016-03-01

    Breast cancer is the most common malignancy in women in well-developed countries. Despite a constant increase in its incidence, the percentage of patients diagnosed with the disease in the non-invasive stage is also rising. This allows more frequently for the use of breast-preserving surgical techniques, involving the breast and the regional lymphatic system. According to current guidelines of expert panels and research societies, the recommended method of identifying the sentinel lymph node is the use of an isotope marker with a dye (a combined isotope and dye method). Cooperation with a nuclear medicine unit is essential (performing a preoperative lymphoscintigraphic scan to identify the lymphatic drainage basin and sentinel lymph node). In the case of smaller centers treating breast cancer, it can be associated with a number of difficulties, including organizational ones, and also increasing general treatment costs. A possible solution to these problems is to use alternative techniques of visualizing the sentinel lymph node, which do not require a radiotracer. In this paper we discuss the currently available methods of mapping the lymphatic system of the axillary region in patients with early breast cancer. The review is limited to reporting on methods of proven (based on clinical research) high diagnostic value. PMID:27095960

  9. Dual-Band Miniaturized Patch Antennas for Microwave Breast Imaging

    OpenAIRE

    Al-Joumayly, Mudar A.; Aguilar, Suzette M.; Behdad, Nader; Hagness, Susan C.

    2010-01-01

    We present a miniaturized, dual-band patch antenna array element that is designed for use in a 3-D microwave tomography system for breast imaging. Dual-band operation is achieved by manipulating the fundamental resonant mode of the patch antenna and one of its higher-order modes. Miniaturization and tuning of the resonant frequencies are achieved by loading the antenna with non-radiating slots at strategic locations along the patch. This results in a compact, dual-band antenna with symmetric ...

  10. Bioluminescence imaging of estrogen receptor activity during breast cancer progression.

    Science.gov (United States)

    Vantaggiato, Cristina; Dell'Omo, Giulia; Ramachandran, Balaji; Manni, Isabella; Radaelli, Enrico; Scanziani, Eugenio; Piaggio, Giulia; Maggi, Adriana; Ciana, Paolo

    2016-01-01

    Estrogen receptors (ER) are known to play an important regulatory role in mammary gland development as well as in its neoplastic transformation. Although several studies highlighted the contribution of ER signaling in the breast transformation, little is known about the dynamics of ER state of activity during carcinogenesis due to the lack of appropriate models for measuring the extent of receptor signaling in time, in the same animal. To this aim, we have developed a reporter mouse model for the non-invasive in vivo imaging of ER activity: the ERE-Luc reporter mouse. ERE-Luc is a transgenic mouse generated with a firefly luciferase (Luc) reporter gene driven by a minimal promoter containing an estrogen responsive element (ERE). This model allows to measure receptor signaling in longitudinal studies by bioluminescence imaging (BLI). Here, we have induced sporadic mammary cancers by treating systemically ERE-Luc reporter mice with DMBA (9,10-dimethyl 1,2-benzanthracene) and measured receptor signaling by in vivo imaging in individual animals from early stage until a clinically palpable tumor appeared in the mouse breast. We showed that DMBA administration induces an increase of bioluminescence in the whole abdominal area 6 h after treatment, the signal rapidly disappears. Several weeks later, strong bioluminescence is observed in the area corresponding to the mammary glands. In vivo and ex vivo imaging analysis demonstrated that this bioluminescent signal is localized in the breast area undergoing neoplastic transformation. We conclude that this non-invasive assay is a novel relevant tool to identify the activation of the ER signaling prior the morphological detection of the neoplastic transformation. PMID:27069764

  11. Breast MR Imaging: What the Radiologist Needs to Know

    Directory of Open Access Journals (Sweden)

    Gurpreet S Dhillon

    2011-01-01

    Full Text Available Magnetic resonance imaging (MRI of the breast is being performed more frequently to improve primary and recurrent tumor detection, characterization, and response to therapy. Sensitivity of this test approaches 90% and the specificity ranges from 37% to 100%. We present a concise tutorial for the general radiologist with a pictorial review of common lesions identified with breast MRI.

  12. Immunophenotyping invasive breast cancer: paving the road for molecular imaging.

    NARCIS (Netherlands)

    Vermeulen, J.F.; Brussel, A.S. van; Groep, P. van der; Morsink, F.H.; Bult, P.; Wall, E. van der; Diest, P.J. van

    2012-01-01

    ABSTRACT: BACKGROUND: Mammographic population screening in The Netherlands has increased the number of breast cancer patients with small and non-palpable breast tumors. Nevertheless, mammography is not ultimately sensitive and specific for distinct subtypes. Molecular imaging with targeted tracers m

  13. Breast Cancer in Systemic Lupus Erythematosus

    DEFF Research Database (Denmark)

    Tessier Cloutier, B; Clarke, A E; Ramsey-Goldman, R;

    2013-01-01

    Evidence points to a decreased breast cancer risk in systemic lupus erythematosus (SLE). We analyzed data from a large multisite SLE cohort, linked to cancer registries.......Evidence points to a decreased breast cancer risk in systemic lupus erythematosus (SLE). We analyzed data from a large multisite SLE cohort, linked to cancer registries....

  14. Review of Metaplastic Carcinoma of the Breast: Imaging Findings and Pathologic Features

    Directory of Open Access Journals (Sweden)

    Rebecca Leddy

    2012-01-01

    Full Text Available Metaplastic carcinoma (MPC, an uncommon but often aggressive breast cancer, can be challenging to differentiate from other types of breast cancer and even benign lesions based on the imaging appearance. It has a variable pathology classification system. These types of tumors are generally rapidly growing palpable masses. MPCs on imaging can present with imaging features similar to invasive ductal carcinoma and probably even benign lesions. The purpose of this article is to review MPC of the breast including the pathology subtypes, imaging features, and imaging pathology correlations. By understanding the clinical picture, pathology, and overlap in imaging characteristics of MPC with invasive ductal carcinoma and probably benign lesions can assist in diagnosing these difficult malignancies.

  15. Image-guided breast biopsy: state-of-the-art.

    Science.gov (United States)

    O'Flynn, E A M; Wilson, A R M; Michell, M J

    2010-04-01

    Percutaneous image-guided breast biopsy is widely practised to evaluate predominantly non-palpable breast lesions. There has been steady development in percutaneous biopsy techniques. Fine-needle aspiration cytology was the original method of sampling, followed in the early 1990s by large core needle biopsy. The accuracy of both has been improved by ultrasound and stereotactic guidance. Larger bore vacuum-assisted biopsy devices became available in the late 1990s and are now commonplace in most breast units. We review the different types of breast biopsy devices currently available together with various localization techniques used, focusing on their advantages, limitations and current controversial clinical management issues. PMID:20338392

  16. Image-guided breast biopsy: state-of-the-art

    International Nuclear Information System (INIS)

    Percutaneous image-guided breast biopsy is widely practised to evaluate predominantly non-palpable breast lesions. There has been steady development in percutaneous biopsy techniques. Fine-needle aspiration cytology was the original method of sampling, followed in the early 1990s by large core needle biopsy. The accuracy of both has been improved by ultrasound and stereotactic guidance. Larger bore vacuum-assisted biopsy devices became available in the late 1990s and are now commonplace in most breast units. We review the different types of breast biopsy devices currently available together with various localization techniques used, focusing on their advantages, limitations and current controversial clinical management issues.

  17. Image-guided breast biopsy: state-of-the-art

    Energy Technology Data Exchange (ETDEWEB)

    O' Flynn, E.A.M., E-mail: lizoflynn@doctors.org.u [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom); Wilson, A.R.M.; Michell, M.J. [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom)

    2010-04-15

    Percutaneous image-guided breast biopsy is widely practised to evaluate predominantly non-palpable breast lesions. There has been steady development in percutaneous biopsy techniques. Fine-needle aspiration cytology was the original method of sampling, followed in the early 1990s by large core needle biopsy. The accuracy of both has been improved by ultrasound and stereotactic guidance. Larger bore vacuum-assisted biopsy devices became available in the late 1990s and are now commonplace in most breast units. We review the different types of breast biopsy devices currently available together with various localization techniques used, focusing on their advantages, limitations and current controversial clinical management issues.

  18. Imaging dose in breast radiotherapy: does breast size affect the dose to the organs at risk and the risk of secondary cancer to the contralateral breast?

    Energy Technology Data Exchange (ETDEWEB)

    Batumalai, Vikneswary, E-mail: vikneswary.batumalai@sswahs.nsw.gov.au [Liverpool Cancer Therapy Centre and Ingham Institute, Liverpool, New South Wales (Australia); South Western Clinical School, University of New South Wales, Sydney, New South Wales (Australia); Quinn, Alexandra; Jameson, Michael [Liverpool Cancer Therapy Centre and Ingham Institute, Liverpool, New South Wales (Australia); Centre for Medical Radiation Physics, University of Wollongong, Wollongong, New South Wales (Australia); Delaney, Geoff [Liverpool Cancer Therapy Centre and Ingham Institute, Liverpool, New South Wales (Australia); South Western Clinical School, University of New South Wales, Sydney, New South Wales (Australia); Collaboration for Cancer Outcomes Research and Evaluation, Liverpool Hospital, Liverpool, New South Wales (Australia); School of Medicine, University of Western Sydney, New South Wales (Australia); Holloway, Lois [Liverpool Cancer Therapy Centre and Ingham Institute, Liverpool, New South Wales (Australia); South Western Clinical School, University of New South Wales, Sydney, New South Wales (Australia); Centre for Medical Radiation Physics, University of Wollongong, Wollongong, New South Wales (Australia); School of Physics, University of Sydney, Sydney, New South Wales (Australia)

    2015-03-15

    Correct target positioning is crucial for accurate dose delivery in breast radiotherapy resulting in utilisation of daily imaging. However, the radiation dose from daily imaging is associated with increased probability of secondary induced cancer. The aim of this study was to quantify doses associated with three imaging modalities and investigate the correlation of dose and varying breast size in breast radiotherapy. Planning computed tomography (CT) data sets of 30 breast cancer patients were utilised to simulate the dose received by various organs from a megavoltage computed tomography (MV-CT), megavoltage electronic portal image (MV-EPI) and megavoltage cone-beam computed tomography (MV-CBCT). The mean dose to organs adjacent to the target volume (contralateral breast, lungs, spinal cord and heart) were analysed. Pearson correlation analysis was performed to determine the relationship between imaging dose and primary breast volume and the lifetime attributable risk (LAR) of induced secondary cancer was calculated for the contralateral breast. The highest contralateral breast mean dose was from the MV-CBCT (1.79 Gy), followed by MV-EPI (0.22 Gy) and MV-CT (0.11 Gy). A similar trend was found for all organs at risk (OAR) analysed. The primary breast volume inversely correlated with the contralateral breast dose for all three imaging modalities. As the primary breast volume increases, the likelihood of a patient developing a radiation-induced secondary cancer to the contralateral breast decreases. MV-CBCT showed a stronger relationship between breast size and LAR of developing a radiation-induced contralateral breast cancer in comparison with the MV-CT and MV-EPI. For breast patients, imaging dose to OAR depends on imaging modality and treated breast size. When considering the use of imaging during breast radiotherapy, the patient's breast size and contralateral breast dose should be taken into account.

  19. Imaging dose in breast radiotherapy: does breast size affect the dose to the organs at risk and the risk of secondary cancer to the contralateral breast?

    International Nuclear Information System (INIS)

    Correct target positioning is crucial for accurate dose delivery in breast radiotherapy resulting in utilisation of daily imaging. However, the radiation dose from daily imaging is associated with increased probability of secondary induced cancer. The aim of this study was to quantify doses associated with three imaging modalities and investigate the correlation of dose and varying breast size in breast radiotherapy. Planning computed tomography (CT) data sets of 30 breast cancer patients were utilised to simulate the dose received by various organs from a megavoltage computed tomography (MV-CT), megavoltage electronic portal image (MV-EPI) and megavoltage cone-beam computed tomography (MV-CBCT). The mean dose to organs adjacent to the target volume (contralateral breast, lungs, spinal cord and heart) were analysed. Pearson correlation analysis was performed to determine the relationship between imaging dose and primary breast volume and the lifetime attributable risk (LAR) of induced secondary cancer was calculated for the contralateral breast. The highest contralateral breast mean dose was from the MV-CBCT (1.79 Gy), followed by MV-EPI (0.22 Gy) and MV-CT (0.11 Gy). A similar trend was found for all organs at risk (OAR) analysed. The primary breast volume inversely correlated with the contralateral breast dose for all three imaging modalities. As the primary breast volume increases, the likelihood of a patient developing a radiation-induced secondary cancer to the contralateral breast decreases. MV-CBCT showed a stronger relationship between breast size and LAR of developing a radiation-induced contralateral breast cancer in comparison with the MV-CT and MV-EPI. For breast patients, imaging dose to OAR depends on imaging modality and treated breast size. When considering the use of imaging during breast radiotherapy, the patient's breast size and contralateral breast dose should be taken into account

  20. Speckle reduction approach for breast ultrasound image and its application to breast cancer diagnosis

    International Nuclear Information System (INIS)

    Objectives: To retrospectively evaluate the effects of a speckle reduction algorithm on radiologists' diagnosis of malignant and benign breast lesions on ultrasound (US) images. Methods: Using a database of 603 breast (US) images of 211 cases (109 benign lesions and 102 malignant ones), the original and speckle-reduced images were assessed by five radiologists and final assessment categories were assigned to indicate the probability of malignancy according to BI-RADS-US. The diagnostic sensitivity and specificity were investigated by the areas (Az) under the receiver operating characteristic (ROC) curves. Results: The sensitivity and specificity of breast lesions on Ultrasound images improved from 88.7% to 94.3%, from 68.6% to 75.2%, respectively, and the area (Az) under ROC curve of diagnosis also increased from 0.843 to 0.939, Z = 4.969, there were significant differences in the Az between the original breast lesions and speckle-reduced ones on Ultrasound images (P < 0.001). The diagnostic accuracy of breast lesions had been highly improved from 78.67% to 92.73% after employing this algorithm. Conclusions: The results demonstrate the promising performance of the proposed speckle reduction algorithm in distinguishing malignant from benign breast lesions which will be useful for breast cancer diagnosis.

  1. MR imaging-guided biopsy and localization of the breast

    International Nuclear Information System (INIS)

    If suspicious lesions found with MR imaging cannot be visualized by either mammography or ultrasound, MR imaging - based guidance systems are needed to guide needle biopsy or to allow localization of the lesion before surgery. The authors give an overview of the advantages and disadvantages of biopsy devices presented by different working groups. Furthermore, MR-compatible needle equipment for interventions of the breast is demonstrated. The angulation of the needle and the type of sequence are the most important factors for signal loss due to susceptibility. The strategy in special problem cases (multicentricity, bilateral lesions) is discussed. Control MR imaging within the first week after open biopsy is the best way to document the complete excision of a suspicious hypervascularized lesion after MR-guided wire localization. At our institute, percutaneous biopsy (36 interventions) revealed benign findings in 67% and malignant lesions in 25% of cases. Three biopsies were insufficient. Histology after MR-guided wire localization (136 interventions) showed benign findings in 51% and malignancy in 49% of cases. The suspicious lesion was missed by the surgeion in three cases. We perform MR-guided interventions of the breast routinely in indicated cases. (orig.)

  2. Evaluation of scatter effects on image quality for breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Wu Gang; Mainprize, James G.; Boone, John M.; Yaffe, Martin J. [Imaging Research, Sunnybrook Health Sciences Centre, S-657, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 (Canada) and Department of Medical Biophysics, University of Toronto, Toronto, Ontario M4N 3M5 (Canada); Department of Medical Biophysics, University of Toronto, Toronto, Ontario M4N 3M5 (Canada); Department of Radiology, X-ray Imaging Laboratory, U. C. Davis Medical Center, 4701 X Street, Sacramento, California 95817 and Department of Biomedical Engineering, University of California, Davis, California 95616 (United States); Imaging Research, Sunnybrook Health Sciences Centre, S-657, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 (Canada) and Department of Medical Biophysics, University of Toronto, Toronto, Ontario M4N 3M5 (Canada)

    2009-10-15

    Digital breast tomosynthesis uses a limited number (typically 10-20) of low-dose x-ray projections to produce a pseudo-three-dimensional volume tomographic reconstruction of the breast. The purpose of this investigation was to characterize and evaluate the effect of scattered radiation on the image quality for breast tomosynthesis. In a simulation, scatter point spread functions generated by a Monte Carlo simulation method were convolved over the breast projection to estimate the distribution of scatter for each angle of tomosynthesis projection. The results demonstrate that in the absence of scatter reduction techniques, images will be affected by cupping artifacts, and there will be reduced accuracy of attenuation values inferred from the reconstructed images. The effect of x-ray scatter on the contrast, noise, and lesion signal-difference-to-noise ratio (SDNR) in tomosynthesis reconstruction was measured as a function of the tumor size. When a with-scatter reconstruction was compared to one without scatter for a 5 cm compressed breast, the following results were observed. The contrast in the reconstructed central slice image of a tumorlike mass (14 mm in diameter) was reduced by 30%, the voxel value (inferred attenuation coefficient) was reduced by 28%, and the SDNR fell by 60%. The authors have quantified the degree to which scatter degrades the image quality over a wide range of parameters relevant to breast tomosynthesis, including x-ray beam energy, breast thickness, breast diameter, and breast composition. They also demonstrate, though, that even without a scatter rejection device, the contrast and SDNR in the reconstructed tomosynthesis slice are higher than those of conventional mammographic projection images acquired with a grid at an equivalent total exposure.

  3. In vivo breast sound-speed imaging with ultrasound tomography

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Lianjie [Los Alamos National Laboratory; Li, Cuiping [KARMANOS CANCER INSTITUTE; Duric, Neb [KARMANOS CANCER INSTITUTE; Littrup, Peter [KARMONOS CANCER INSTITUTE

    2009-01-01

    We discuss a bent-ray ultrasound tomography algorithm with total-variation (TV) regularization. We have applied this algorithm to 61 in vivo breast datasets collected with our in-house clinical prototype for imaging sound-speed distributions in the breast. Our analysis showed that TV regularization could preserve sharper lesion edges than the classic Tikhonov regularization. Furthermore, the image quality of our TV bent-ray sound-speed tomograms was superior to that of the straight-ray counterparts for all types of breasts within BI-RADS density categories 1-4. For all four breast types from fatty to dense, the improvements for average sharpness (in the unit of (m{center_dot} s) {sup -1}) of lesion edges in our TV bent-ray tomograms are between 2.1 to 3.4 fold compared to the straight ray tomograms. Reconstructed sound-speed tomograms illustrated that our algorithm could successfully image fatty and glandular tissues within the breast. We calculated the mean sound-speed values for fatty tissue and breast parenchyma as 1422 {+-} 9 mls (mean{+-} SD) and1487 {+-} 21 mls, respectively. Based on 32 lesions in a cohort of 61 patients, we also found that the mean sound-speed for malignant breast lesions (1548{+-}17 mls) was higher, on average, than that of benign ones (1513{+-}27 mls) (one-sided pbreast density (, and therefore, breast cancer risk), as well as detect and help differentiate breast lesions. Finally, our sound-speed tomograms may also be a useful tool to monitor clinical response of breast cancer patients to neo-adjuvant chemotherapy.

  4. A minimum spanning forest based classification method for dedicated breast CT images

    NARCIS (Netherlands)

    Pike, R.; Sechopoulos, I.; Fei, B.

    2015-01-01

    PURPOSE: To develop and test an automated algorithm to classify different types of tissue in dedicated breast CT images. METHODS: Images of a single breast of five different patients were acquired with a dedicated breast CT clinical prototype. The breast CT images were processed by a multiscale bila

  5. THE CLINICAL SIGNIFICANCE OF 99mTc-MIBI BREAST IMAGING IN THE DIAGNOSIS OF EARLY BREAST CANCER

    Institute of Scientific and Technical Information of China (English)

    任长才; 金少津; 邹强; 朱汇庆; 王红鹰; 梁春立

    2001-01-01

    Objective: To find an effective, sensitive, specific and noninvasive diagnostic method of breast cancer. Methods: 109 masses of 102 patients with breast lesions smaller than 2 cm in diameter were divided into three groups to undergo 99mTc-MIBI imaging and compared with the results of pathology examination. 20 cases without breast lesions were selected as control. Abnormal condensation of 99mTc-MIBI in the breast reaching 10% higher than that in the counterpart of the healthy breast was regarded as positive. Results: Of 32 breast cancers, positive imaging appeared in 25. Negative imaging were found in 31 of 38 benign breast lesions. Of 39 occult breast lesions, positive imaging appeared in 6 and 3 of them were breast cancer, 2 of 3 patients with slightly increased 99mTc-MIBI imaging threshold were breast cancer also. No positive imaging was found in the control group. The diagnostic accuracy, sensitivity, specificity, positive predictive value, negative predictive value of 99mTc-MIBI was 88.4%, 89.2%, 88.0%, 75.0% and 95.3%, respectively. Conclusion: 99mTc-MIBI imaging had higher sensitivity and accuracy in the diagnosis of breast cancer and differentiation between benign and malignant breast lesions. It could provide useful information for the diagnosis of clinically suspected breast cancer.

  6. Double difference tomography for breast ultrasound sound speed imaging

    Science.gov (United States)

    Li, Cuiping; Duric, Neb; Rama, Olsi; Burger, Angelika; Polin, Lisa; Nechiporchik, Nicole

    2011-03-01

    Breast ultrasound tomography is a rapidly developing imaging modality that has the potential to impact breast cancer screening and diagnosis. Double difference (DD) tomography utilizes more accurate differential time-of-flight (ToF) data to reconstruct the sound speed structure of the breast. It can produce more precise and better resolution sound speed images than standard tomography that uses absolute ToF data. We apply DD tomography to phantom data and excised mouse mammary glands data. DD tomograms demonstrate sharper sound speed contrast than the standard tomograms.

  7. Multicenter prospective study of magnetic resonance imaging prior to breast-conserving surgery for breast cancer

    Institute of Scientific and Technical Information of China (English)

    Liu Qian; Liu Yinhua; Xu Ling; Duan Xuening; Li Ting; Qin Naishan; Kang Hua

    2014-01-01

    Background This multicenter prospective study aimed to assess the utility of dynamic enhanced magnetic resonance imaging (MRI) prior to breast-conserving surgery for breast cancer.Methods The research subjects were drawn from patients with primary early resectable breast cancer treated in the breast disease centers of six three-level hospitals in Beijing from 1 January 2010 to 31 December 2012.The participants were allocated to a breast-conserving surgery group (breast-conserving group) or a total mastectomy group (total mastectomy group).Enhanced MRI was used to measure breast volume,longest diameter of tumor and tumor volume.The correlations between these measurements and those derived from histopathologic findings were assessed.The relationships between the success rate of breast-conserving surgery and MRI-and pathology-based measurement results were statistically analyzed in the breast-conserving group.Results The study included 461 cases in the total mastectomy group and 195 in the breast-conserving group.Allocation to these groups was based on clinical indications and patient preferences.The cut-off for concurrence between MRI-and pathology-based measurements of the longest diameter of tumor was set at 0.3 cm.In the total mastectomy group,the confidence interval for 95% concurrence of these measurements was 35.41%-44.63%.Correlation coefficients for MRI and histopathology-based measurements of breast volume,tumor volume and tumor volume/breast volume ratio were r=0.861,0.569,and 0.600,respectively (all P <0.001).In the breast-conserving group,with 0.30 cm taken as the cut-off for concurrence,the 95% confidence interval for MRI and pathology-based measurements of the longest diameter of tumor was 29.98%-44.01%.The subjective and objective success rates for breast-conserving surgery were 100% and 88.54%,respectively.Conclusions There were significant correlations between dynamic enhanced MRI-and histopathology-based measurements of the longest

  8. Breast imaging technology: Application of magnetic resonance imaging to early detection of breast cancer

    International Nuclear Information System (INIS)

    Since its first introduction approximately 10 years ago, there has been extensive progress in the application of magnetic resonance imaging (MRI) to the detection and diagnosis of breast cancer. Contrast-enhanced MRI has been shown to have value in the diagnostic work-up of women who present with mammogram or clinical abnormalities. In addition, it has been demonstrated that MRI can detect mammogram occult multifocal cancer in patients who present with unifocal disease. Advances in risk stratification and limitations in mammography have stimulated interest in the use of MRI to screen high-risk women for cancer. Several studies of MRI high-risk screening are ongoing. Preliminary results are encouraging

  9. Identification of occult breast lesions detected by magnetic resonance imaging with targeted ultrasound: A prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Aracava, Márcia M., E-mail: marcia.aracava@gmail.com; Chojniak, Rubens, E-mail: chojniak@uol.com.br; Souza, Juliana A., E-mail: julianaalves79@hotmail.com; Bitencourt, Almir G.V., E-mail: almirgvb@yahoo.com.br; Marques, Elvira F., E-mail: elvira.marques@ig.com.br

    2014-03-15

    Objective: To verify the capacity of targeted ultrasound (US) to identify additional lesions detected on breast magnetic resonance imaging (MRI), but occult to initial mammography, US and clinical examinations. Methods: This prospective study included 68 additional relevant breast lesions identified on MRI of 49 patients. As an inclusion criterion, breast US and mammography were required and performed up to six months before MRI. These lesions were then subjected to targeted “second-look” US up to 2 weeks after MRI, performed by one or two radiologists with expertise on breast imaging. Lesions were evaluated according to the established Breast Imaging Report and Data System (BI-RADS) lexicon. Results: Targeted US identified 46/68 (67.6%) lesions revealed by MRI. No significant associations were observed between US identification and the type of lesion, dimensions, morphological characteristics and enhancement pattern according to MRI findings. Targeted US identified 100% of BI-RADS category 5 lesions, 90% of category 4 lesions, and just over 50% of category 3 lesions (p < 0.05). There was significant agreement (p < 0.001) between MRI and US BI-RADS classification for all three categories. Conclusion: Targeted US can identify a large proportion of the lesions detected by breast MRI, especially those at high risk of malignancy, when performed by a professional with experience in both breast US and MRI.

  10. Identification of occult breast lesions detected by magnetic resonance imaging with targeted ultrasound: A prospective study

    International Nuclear Information System (INIS)

    Objective: To verify the capacity of targeted ultrasound (US) to identify additional lesions detected on breast magnetic resonance imaging (MRI), but occult to initial mammography, US and clinical examinations. Methods: This prospective study included 68 additional relevant breast lesions identified on MRI of 49 patients. As an inclusion criterion, breast US and mammography were required and performed up to six months before MRI. These lesions were then subjected to targeted “second-look” US up to 2 weeks after MRI, performed by one or two radiologists with expertise on breast imaging. Lesions were evaluated according to the established Breast Imaging Report and Data System (BI-RADS) lexicon. Results: Targeted US identified 46/68 (67.6%) lesions revealed by MRI. No significant associations were observed between US identification and the type of lesion, dimensions, morphological characteristics and enhancement pattern according to MRI findings. Targeted US identified 100% of BI-RADS category 5 lesions, 90% of category 4 lesions, and just over 50% of category 3 lesions (p < 0.05). There was significant agreement (p < 0.001) between MRI and US BI-RADS classification for all three categories. Conclusion: Targeted US can identify a large proportion of the lesions detected by breast MRI, especially those at high risk of malignancy, when performed by a professional with experience in both breast US and MRI

  11. Emotional distress in women presenting for breast imaging

    International Nuclear Information System (INIS)

    The aim of this study was to assess anxiety and depression in a sample of women presenting for imaging of breast following a clinical referral. Emotional distress in the women was also assessed in relation to demographic factors, reason for referral, presence for breast symptoms, type of imaging procedure performed and self-reported pain and discomfort during imaging. The study comprised 167 patients. The Hopkins Symptom Checklist-25 (HSCL-25) and a discomfort rating scale were used to assess emotional distress and discomfort or pain experienced during the imaging. While less than 10% of all subjects scored above psychiatric cut-off points for anxiety and depression, 25% and 20% reported significant distress associated with anxiety and depression symptoms respectively. Education alone was associated with higher anxiety scores, while the presence of breast symptoms significantly increased depression scores and reports of specific nonsomatic symptoms of depression. Higher anxiety and depression scores were also associated with pain experienced during the imaging procedure. Emotional distress may negatively impact women's experience of breast imaging. Screening for emotional distress is important within the context of breast imaging. (author)

  12. Invasive ductal carcinoma arising from dense accessory breast visualized with 99mTc-MIBI breast-specific γ imaging.

    Science.gov (United States)

    Yoon, Hai-Jeon; Sung, Sun Hee; Moon, Byung In; Kim, Bom Sahn

    2014-08-01

    Primary accessory breast cancer is extremely rare, and the diagnostic efficacy of Tc-MIBI breast-specific γ imaging (BSGI) has not been reported elsewhere. We present a case of primary carcinoma arising from dense accessory breast that was visualized with BSGI. A 43-year-old female patient with a palpable axillary mass underwent mammography, which showed dense parenchyma on both of the anatomic and accessory breasts with no abnormality. Subsequent BSGI showed no abnormal uptake in bilateral anatomic breasts, but focal abnormal uptake was noted in the accessory breast. Permanent pathologic evaluation confirmed invasive ductal carcinoma (not otherwise specified type) of the accessory breast. PMID:24445272

  13. Study Manual for breast imaging for radiology residents

    International Nuclear Information System (INIS)

    Breast cancer is a disease that affects women worldwide. This cancer has become a public health problem, currently holding the first incidence and mortality from neoplasms in women of Costa Rica. That's why early detection makes it so important, so you should educate patients about the importance of annual mammograms, regular breast self-examination and consult immediately with the appearance of any abnormality in the breast. Mammography has been the only continuous proven method of screening for breast cancer. However, breast ultrasound is a valuable and effective tool for the evaluation and diagnosis of breast disease. The country lacks a picture book in the breast that fits entirely on the conditions of post-degree program, be practical and use the own methodology of the health system; therefore, the objective of this research is to organize a manual with the review of recent literature on the radiologic evaluation of the breast, with guidance on the methodology and the own resources of the country. This manual aims to provide a guide or basis for the radiologist in training, the important task of obtaining the knowledge, skill and ability to meet the enormous responsibility to participate in early detection of breast cancer. It also may help prevent the development and progression of the dreaded breast cancer in patients during their subsequent professional performance. (author)

  14. The application of breast specific gamma imaging and positron emission mammography in the diagnosis and therapy of breast cancer

    International Nuclear Information System (INIS)

    Breast-specific gamma imaging (BSGI) and positron emission mammography (PEM) have the high resolution in diagnosing breast lesions with minimum diameter of 3 mm. Both BSGI and PEM are functional imaging modalities, which have no relation with breast tissue density, implanted prosthesis, scar formation and so on. This review elaborates the application of BSGI and PEM in the early diagnosis, treatment protocols and evaluation of efficacy for the patients with breast cancer. (authors)

  15. Characterization of human breast cancer tissues by infrared imaging.

    Science.gov (United States)

    Verdonck, M; Denayer, A; Delvaux, B; Garaud, S; De Wind, R; Desmedt, C; Sotiriou, C; Willard-Gallo, K; Goormaghtigh, E

    2016-01-21

    Fourier Transform InfraRed (FTIR) spectroscopy coupled to microscopy (IR imaging) has shown unique advantages in detecting morphological and molecular pathologic alterations in biological tissues. The aim of this study was to evaluate the potential of IR imaging as a diagnostic tool to identify characteristics of breast epithelial cells and the stroma. In this study a total of 19 breast tissue samples were obtained from 13 patients. For 6 of the patients, we also obtained Non-Adjacent Non-Tumor tissue samples. Infrared images were recorded on the main cell/tissue types identified in all breast tissue samples. Unsupervised Principal Component Analyses and supervised Partial Least Square Discriminant Analyses (PLS-DA) were used to discriminate spectra. Leave-one-out cross-validation was used to evaluate the performance of PLS-DA models. Our results show that IR imaging coupled with PLS-DA can efficiently identify the main cell types present in FFPE breast tissue sections, i.e. epithelial cells, lymphocytes, connective tissue, vascular tissue and erythrocytes. A second PLS-DA model could distinguish normal and tumor breast epithelial cells in the breast tissue sections. A patient-specific model reached particularly high sensitivity, specificity and MCC rates. Finally, we showed that the stroma located close or at distance from the tumor exhibits distinct spectral characteristics. In conclusion FTIR imaging combined with computational algorithms could be an accurate, rapid and objective tool to identify/quantify breast epithelial cells and differentiate tumor from normal breast tissue as well as normal from tumor-associated stroma, paving the way to the establishment of a potential complementary tool to ensure safe tumor margins. PMID:26535413

  16. A comparative study on image quality of breast image tests using ACR phantom

    International Nuclear Information System (INIS)

    Recently, interests and utilization on Computed Radiography (CR) and Digital Radiography (DR) tends to increase owing to an introduction of Picture Archiving and Communication System (PACS) and an accuracy control of special medical equipment for a breast imaging examination. This study was intended to compare and analyze a detector's imaging quality by each system to be used for the breast imaging examination by using ACR Phantom used at the accuracy control. As an evaluation method, a significance and reliability of image's value using the ACR Phantom was analyzed by using SPSS program. The results are followed. For the fiber, there was 3.9 score in Screen-Film, 4.2 score in CR (50 μ m), 3.2 score in CR(100 μ m), and 4.2 score in DR. There was the high score in the order of CR (50 μ m), DR, Screen-Film, and CR (100 μ m) (ρ < 0.05). For the calcification, there was 2.7 score in Screen-Film, 2.5 score in CR (50 μ m), 2.0 score in CR (100 μ m), and 2.9 score in DR. There was the high score in the order of DR, Screen-Film, CR (50 μ m), and CR (100 μ m). (0.025(ρ < 0.05). For Mass, there was 3.8 score in Screen-Film, 3.8 score in CR (50 μ m), 3.6 score in CR (100 μ m), and 4.5 score in DR. There was the high score in the order of DR, CR (50 μ m), Screen-Film, and CR (100 μ m) (ρ < 0.1). As the total score, there was 10.4 score in Screen-Film, 10.6 score in CR (50 μ m), 8.7 score in CR (100 μ m), and 11.3 score in DR. There was the high score in the order of DR, CR (50 μ m), Screen-Film, and CR (100 μ m). As shown in the above results, it can be known that DR and Screen-Film System has higher image quality than CR. But, DR has unstability caused by element, and Screen-Film has the low image quality caused by artifact as disadvantages. When Dual-Side CR (50 μ m) was used among CR system which had the problem of low image quality, it was indicated that there was no difference with Screen-Film System. Because the radiation imaging examination tends to

  17. Effect of the glandular composition on digital breast tomosynthesis image quality and dose optimisation

    International Nuclear Information System (INIS)

    In the image quality assessment for digital breast tomosynthesis (DBT), a breast phantom with an average percentage of 50 % glandular tissue is seldom used, which may not be representative of the breast tissue composition of the women undergoing such examination. This work aims at studying the effect of the glandular composition of the breast on the image quality taking into consideration different sizes of lesions. Monte Carlo simulations were performed using the state-of-the-art computer program PENELOPE to validate the image acquisition system of the DBT equipment as well as to calculate the mean glandular dose for each projection image and for different breast compositions. The integrated PENELOPE imaging tool (PenEasy) was used to calculate, in mammography, for each clinical detection task the X-ray energy that maximises the figure of merit. All the 2D cranial-caudal projections for DBT were simulated and then underwent the reconstruction process applying the Simultaneous Algebraic Reconstruction Technique. Finally, through signal-to-noise ratio analysis, the image quality in DBT was assessed. (authors)

  18. Effect of the glandular composition on digital breast tomosynthesis image quality and dose optimisation.

    Science.gov (United States)

    Marques, T; Ribeiro, A; Di Maria, S; Belchior, A; Cardoso, J; Matela, N; Oliveira, N; Janeiro, L; Almeida, P; Vaz, P

    2015-07-01

    In the image quality assessment for digital breast tomosynthesis (DBT), a breast phantom with an average percentage of 50 % glandular tissue is seldom used, which may not be representative of the breast tissue composition of the women undergoing such examination. This work aims at studying the effect of the glandular composition of the breast on the image quality taking into consideration different sizes of lesions. Monte Carlo simulations were performed using the state-of-the-art computer program PENELOPE to validate the image acquisition system of the DBT equipment as well as to calculate the mean glandular dose for each projection image and for different breast compositions. The integrated PENELOPE imaging tool (PenEasy) was used to calculate, in mammography, for each clinical detection task the X-ray energy that maximises the figure of merit. All the 2D cranial-caudal projections for DBT were simulated and then underwent the reconstruction process applying the Simultaneous Algebraic Reconstruction Technique. Finally, through signal-to-noise ratio analysis, the image quality in DBT was assessed. PMID:25836692

  19. Ectopic Axillary Breast during Systemic Lupus

    OpenAIRE

    2012-01-01

    Many breast changes may occur in systemic lupus erythematosus. We report a 41-year-old woman with lupus who presented three years after the onset of lupus an ectopic mammary gland confirmed by histological study.

  20. Ectopic Axillary Breast during Systemic Lupus

    Directory of Open Access Journals (Sweden)

    Besma Ben Dhaou

    2012-01-01

    Full Text Available Many breast changes may occur in systemic lupus erythematosus. We report a 41-year-old woman with lupus who presented three years after the onset of lupus an ectopic mammary gland confirmed by histological study.

  1. Monte Carlo simulation for the estimation of the glandular breast dose for a digital breast tomosynthesis system

    International Nuclear Information System (INIS)

    Digital breast tomosynthesis (DBT) is a screening and diagnostic modality that acquires images of the breast at multiple angles during a short scan. The Selenia Dimensions (Hologic, Bedford, Mass) DBT system can perform both full-field digital mammography and DBT. The system acquires 15 projections over a 15 deg. angular range (from -7.5 deg. to +7.5 deg.). An important factor in determining the optimal imaging technique for breast tomosynthesis is the radiation dose. In breast imaging, the radiation dose of concern is that deposited in the glandular tissue of the breast because this is the tissue that has a risk of developing cancer. The concept of the normalised mean glandular dose (DgN) has been introduced as the metric for the dose in breast imaging. The DgN is difficult to measure. The Monte Carlo techniques offer an alternative method for a realistic estimation of the radiation dose. The purpose of this work was to use the Monte Carlo code MCNPX technique to generate monoenergetic glandular dose data for estimating the breast tissue dose in tomosynthesis for arbitrary spectra as well as to observe the deposited radiation dose by projection on the glandular portion of the breast in a Selenia Dimensions DBT system. A Monte Carlo simulation of the system was developed to compute the DgN in a craniocaudal view. Monoenergetic X-ray beams from 10 to 49 keV in 1-keV increments were used. The simulation utilised the assumption of a homogeneous breast composition and three compositions (0 % glandular, 50 % glandular and 100 % glandular). The glandular and adipose tissue compositions were specified according ICRU Report 44. A skin layer of 4 mm was assumed to encapsulate the breast on all surfaces. The breast size was varied using the chest wall-to-nipple distance (CND) and compressed breast thickness (t). In this work, the authors assumed a CND of 5 cm and the thicknesses ranged from 2 to 8 cm, in steps of 2 cm. The fractional energy absorption increases (up to 44

  2. Effect of shaped filter design on dose and image quality in breast CT

    International Nuclear Information System (INIS)

    The purpose of this study was to investigate the effect of shaped filters specifically designed for dedicated breast computed tomography (CT) scanners on dose and image quality. Optimization of filter shape and material in fan direction was performed using two different design methods, one aiming at homogeneous noise distributions in the CT images and the other aiming at a uniform dose distribution in the breast. The optimal filter thickness as a function of fan angle was determined iteratively to fulfil the above mentioned criteria for each breast diameter. Different filter materials (aluminium, copper, carbon, polytetrafluoroethylene) and breast phantoms with diameters between 80–180 mm were investigated. Noise uniformity in the reconstructed images, obtained from CT simulations based on ray-tracing methods, and dose in the breast, calculated with a Monte Carlo software tool, were used as figure of merit. Furthermore, CT-value homogeneity, the distribution of noise in cone direction, spatial resolution from centre to periphery and the contrast-to-noise ratio weighted by dose (CNRD) were evaluated. In addition, the decrease of scatter due to shaped filters was investigated. Since only few or one filter are practical in clinical CT systems, the effects of one shaped filter for different breast diameters were also investigated. In this case the filter, designed for the largest breast diameter, was simulated at variable source-to-filter distances depending on breast diameter. With the filter design method aiming at uniform noise distribution best results were obtained for aluminium as the filter material. Noise uniformity improved from 20% down to 5% and dose was reduced by about 30–40% for all breast diameters. No decrease of noise uniformity in cone direction, CT-value homogeneity, spatial resolution and the CNRD was detected with the shaped filter. However, a small improvement of CNRD was observed. Furthermore, a scatter reduction of about 20–30% and a more

  3. Elastography of the Breast: Imaging Techniques and Pitfalls in Interpretation

    International Nuclear Information System (INIS)

    Ultrasound (US) elastography is a tool that indicates the hardness of a lesion. Recent studies using elastography with freehand compression have shown similar diagnostic performance to conventional US in differentiating benign lesions from malignant breast masses. On the other hand, the acquired information is not quantitative, and the reliability of the imaging technique to correctly compress the tissue depends on the skill of the operator, resulting in substantial interobserver variability during data acquisition and interpretation. To overcome this, shear wave elastography was developed to provide quantitative information on the tissue elasticity. The system works by remotely inducing mechanical vibrations through the acoustic radiation force created by a focused US beam. This review discusses the principles and examination techniques of the two types of elastography systems and provides practical points to reduce the interobserver variability or errors during data acquisition and interpretation

  4. Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms

    CERN Document Server

    Sidky, Emil Y; Reiser, Ingrid S; Nishikawa, Robert M; Moore, Richard H; Kopans, Daniel B

    2009-01-01

    PURPOSE: We develop a practical, iterative algorithm for image-reconstruction in under-sampled tomographic systems, such as digital breast tomosynthesis (DBT). METHOD: The algorithm controls image regularity by minimizing the image total $p$-variation (TpV), a function that reduces to the total variation when $p=1.0$ or the image roughness when $p=2.0$. Constraints on the image, such as image positivity and estimated projection-data tolerance, are enforced by projection onto convex sets (POCS). The fact that the tomographic system is under-sampled translates to the mathematical property that many widely varied resultant volumes may correspond to a given data tolerance. Thus the application of image regularity serves two purposes: (1) reduction of the number of resultant volumes out of those allowed by fixing the data tolerance, finding the minimum image TpV for fixed data tolerance, and (2) traditional regularization, sacrificing data fidelity for higher image regularity. The present algorithm allows for this...

  5. Anatomical background noise power spectrum in differential phase contrast breast images

    Science.gov (United States)

    Garrett, John; Ge, Yongshuai; Li, Ke; Chen, Guang-Hong

    2015-03-01

    In x-ray breast imaging, the anatomical noise background of the breast has a significant impact on the detection of lesions and other features of interest. This anatomical noise is typically characterized by a parameter, β, which describes a power law dependence of anatomical noise on spatial frequency (the shape of the anatomical noise power spectrum). Large values of β have been shown to reduce human detection performance, and in conventional mammography typical values of β are around 3.2. Recently, x-ray differential phase contrast (DPC) and the associated dark field imaging methods have received considerable attention as possible supplements to absorption imaging for breast cancer diagnosis. However, the impact of these additional contrast mechanisms on lesion detection is not yet well understood. In order to better understand the utility of these new methods, we measured the β indices for absorption, DPC, and dark field images in 15 cadaver breast specimens using a benchtop DPC imaging system. We found that the measured β value for absorption was consistent with the literature for mammographic acquisitions (β = 3.61±0.49), but that both DPC and dark field images had much lower values of β (β = 2.54±0.75 for DPC and β = 1.44±0.49 for dark field). In addition, visual inspection showed greatly reduced anatomical background in both DPC and dark field images. These promising results suggest that DPC and dark field imaging may help provide improved lesion detection in breast imaging, particularly for those patients with dense breasts, in whom anatomical noise is a major limiting factor in identifying malignancies.

  6. Breast imaging technology: Recent advances in imaging endogenous or transferred gene expression utilizing radionuclide technologies in living subjects - applications to breast cancer

    International Nuclear Information System (INIS)

    A variety of imaging technologies is being investigated as tools for studying gene expression in living subjects. Two technologies that use radiolabeled isotopes are single photon emission computed tomography (SPECT) and positron emission tomography (PET). A relatively high sensitivity, a full quantitative tomographic capability, and the ability to extend small animal imaging assays directly into human applications characterize radionuclide approaches. Various radiolabeled probes (tracers) can be synthesized to target specific molecules present in breast cancer cells. These include antibodies or ligands to target cell surface receptors, substrates for intracellular enzymes, antisense oligodeoxynucleotide probes for targeting mRNA, probes for targeting intracellular receptors, and probes for genes transferred into the cell. We briefly discuss each of these imaging approaches and focus in detail on imaging reporter genes. In a PET reporter gene system for in vivo reporter gene imaging, the protein products of the reporter genes sequester positron emitting reporter probes. PET subsequently measures the PET reporter gene dependent sequestration of the PET reporter probe in living animals. We describe and review reporter gene approaches using the herpes simplex type 1 virus thymidine kinase and the dopamine type 2 receptor genes. Application of the reporter gene approach to animal models for breast cancer is discussed. Prospects for future applications of the transgene imaging technology in human gene therapy are also discussed. Both SPECT and PET provide unique opportunities to study animal models of breast cancer with direct application to human imaging. Continued development of new technology, probes and assays should help in the better understanding of basic breast cancer biology and in the improved management of breast cancer patients

  7. Coded aperture coherent scatter imaging for breast cancer detection: a Monte Carlo evaluation

    Science.gov (United States)

    Lakshmanan, Manu N.; Morris, Robert E.; Greenberg, Joel A.; Samei, Ehsan; Kapadia, Anuj J.

    2016-03-01

    It is known that conventional x-ray imaging provides a maximum contrast between cancerous and healthy fibroglandular breast tissues of 3% based on their linear x-ray attenuation coefficients at 17.5 keV, whereas coherent scatter signal provides a maximum contrast of 19% based on their differential coherent scatter cross sections. Therefore in order to exploit this potential contrast, we seek to evaluate the performance of a coded- aperture coherent scatter imaging system for breast cancer detection and investigate its accuracy using Monte Carlo simulations. In the simulations we modeled our experimental system, which consists of a raster-scanned pencil beam of x-rays, a bismuth-tin coded aperture mask comprised of a repeating slit pattern with 2-mm periodicity, and a linear-array of 128 detector pixels with 6.5-keV energy resolution. The breast tissue that was scanned comprised a 3-cm sample taken from a patient-based XCAT breast phantom containing a tomosynthesis- based realistic simulated lesion. The differential coherent scatter cross section was reconstructed at each pixel in the image using an iterative reconstruction algorithm. Each pixel in the reconstructed image was then classified as being either air or the type of breast tissue with which its normalized reconstructed differential coherent scatter cross section had the highest correlation coefficient. Comparison of the final tissue classification results with the ground truth image showed that the coded aperture imaging technique has a cancerous pixel detection sensitivity (correct identification of cancerous pixels), specificity (correctly ruling out healthy pixels as not being cancer) and accuracy of 92.4%, 91.9% and 92.0%, respectively. Our Monte Carlo evaluation of our experimental coded aperture coherent scatter imaging system shows that it is able to exploit the greater contrast available from coherently scattered x-rays to increase the accuracy of detecting cancerous regions within the breast.

  8. Online advertising by three commercial breast imaging services: message takeout and effectiveness.

    Science.gov (United States)

    Johnson, Rebecca; Jalleh, Geoffrey; Pratt, Iain S; Donovan, Robert J; Lin, Chad; Saunders, Christobel; Slevin, Terry

    2013-10-01

    Mammography is widely acknowledged to be the most cost-effective technique for population screening for breast cancer. Recently in Australia, imaging modalities other than mammography, including thermography, electrical impedance, and computerised breast imaging, have been increasingly promoted as alternative methods of breast cancer screening. This study assessed the impact of three commercial breast imaging companies' promotional material upon consumers' beliefs about the effectiveness of the companies' technology in detecting breast cancer, and consumers' intentions to seek more information or consider having their breasts imaged by these modalities. Results showed 90% of respondents agreed that the companies' promotional material promoted the message that the advertised breast imaging method was effective in detecting breast cancer, and 80% agreed that the material promoted the message that the imaging method was equally or more effective than a mammogram. These findings have implications for women's preference for and uptake of alternative breast imaging services over mammography. PMID:23422256

  9. Stereotactic Image-Guided Navigation During Breast Reconstruction in Patients With Breast Cancer

    Science.gov (United States)

    2015-08-27

    Ductal Breast Carcinoma in Situ; Lobular Breast Carcinoma in Situ; Recurrent Breast Cancer; Stage IA Breast Cancer; Stage IB Breast Cancer; Stage II Breast Cancer; Stage IIIA Breast Cancer; Stage IIIB Breast Cancer; Stage IIIC Breast Cancer; Stage IV Breast Cancer

  10. Identification of breast contour for nipple segmentation in breast magnetic resonance images

    Energy Technology Data Exchange (ETDEWEB)

    Gwo, Chih-Ying [Department of Information Management, Chien Hsin University of Science and Technology, Taoyuan 320, Taiwan (China); Gwo, Allen [Department of Chemistry and Biochemistry, University of Texas at Austin, Austin, Texas 78712 (United States); Wei, Chia-Hung, E-mail: rogerwei@uch.edu.tw [Department of Information Management, Chien Hsin University of Science and Technology, Taoyuan 320, Taiwan and Graduate Institute of Biomedical Informatics, Taipei Medical University, Taipei 110, Taiwan (China); Huang, Pai Jung [Graduate Institute of Biomedical Informatics, Taipei Medical University, Taipei 110, Taiwan and Comprehensive Breast Health Center, Taipei Medical University Hospital, Taipei 110, Taiwan (China)

    2014-02-15

    Purpose: The purpose of this study is to develop a method to simulate the breast contour and segment the nipple in breast magnetic resonance images. Methods: This study first identifies the chest wall and removes the chest part from the breast MR images. Subsequently, the cleavage and its motion artifacts are removed, distinguishing the separate breasts, where the edge points are sampled for curve fitting. Next, a region growing method is applied to find the potential nipple region. Finally, the potential nipple region above the simulated curve can be removed in order to retain the original smooth contour. Results: The simulation methods can achieve the least root mean square error (RMSE) for certain cases. The proposed YBnd and (Dmin+Dmax)/2 methods are significant due toP = 0.000. The breast contour curve detected by the two proposed methods is closer than that determined by the edge detection method. The (Dmin+Dmax)/2 method can achieve the lowest RMSE of 1.1029 on average, while the edge detection method results in the highest RMSE of 6.5655. This is only slighter better than the comparison methods, which implies that the performance of these methods depends upon the conditions of the cases themselves. Under this method, the maximal Dice coefficient is 0.881, and the centroid difference is 0.36 pixels. Conclusions: The contributions of this study are twofold. First, a method was proposed to identify and segment the nipple in breast MR images. Second, a curve-fitting method was used to simulate the breast contour, allowing the breast to retain its original smooth shape.

  11. Brca1/p53 deficient mouse breast tumor hemodynamics during hyperoxic respiratory challenge monitored by a novel wide-field functional imaging (WiFI) system

    Science.gov (United States)

    Moy, Austin; Kim, Jae G.; Lee, Eva Y. H. P.; Tromberg, Bruce; Cerussi, Albert; Choi, Bernard

    2009-02-01

    Current imaging modalities allow precise visualization of tumors but do not enable quantitative characterization of the tumor metabolic state. Such quantitative information would enhance our understanding of tumor progression and response to treatment, and to our overall understanding of tumor biology. To address this problem, we have developed a wide-field functional imaging (WiFI) instrument which combines two optical imaging modalities, spatially modulated imaging (MI) and laser speckle imaging (LSI). Our current WiFI imaging protocol consists of multispectral imaging in the near infrared (650-980 nm) spectrum, over a wide (7 cm × 5 cm) field of view. Using MI, the spatially-resolved reflectance of sinusoidal patterns projected onto the tissue is assessed, and optical properties of the tissue are estimated using a Monte Carlo model. From the spatial maps of local absorption and reduced scattering coefficients, tissue composition information is extracted in the form of oxy-, deoxy-, and total hemoglobin concentrations, and percentage of lipid and water. Using LSI, the reflectance of a 785 nm laser speckle pattern on the tissue is acquired and analyzed to compute maps of blood perfusion in the tissue. Tissue metabolism state is estimated from the values of blood perfusion, volume and oxygenation state. We currently are employing the WiFI instrument to study tumor development in a BRCA1/p53 deficient mice breast tumor model. The animals are monitored with WiFI during hyperoxic respiratory challenge. At present, four tumors have been measured with WiFI, and preliminary data suggest that tumor metabolic changes during hyperoxic respiratory challenge can be determined.

  12. Convergence of iterative image reconstruction algorithms for Digital Breast Tomosynthesis

    DEFF Research Database (Denmark)

    Sidky, Emil; Jørgensen, Jakob Heide; Pan, Xiaochuan

    Most iterative image reconstruction algorithms are based on some form of optimization, such as minimization of a data-fidelity term plus an image regularizing penalty term. While achieving the solution of these optimization problems may not directly be clinically relevant, accurate optimization...... solutions can aid in iterative image reconstruction algorithm design. This issue is particularly acute for iterative image reconstruction in Digital Breast Tomosynthesis (DBT), where the corresponding data model IS particularly poorly conditioned. The impact of this poor conditioning is that iterative....... Math. Imag. Vol. 40, pgs 120-145) and apply it to iterative image reconstruction in DBT....

  13. Optical tomography of the breast using a multi-channel time-resolved imager

    International Nuclear Information System (INIS)

    A time-resolved optical tomography system has been used to generate cross-sectional images of the human breast. Images are reconstructed using an iterative, nonlinear algorithm and measurements of mean photon flight time relative to those acquired on a homogeneous reference phantom. Thirty-eight studies have been performed on three healthy volunteers and 21 patients with a variety of breast lesions including cancer. We have successfully detected 17 out of 19 lesions, and shown that optical images of the healthy breast of the same volunteer display a heterogeneity which is repeatable over a period of months. However, results also indicate that the lack of accurate quantitation of optical parameters and limited morphological information limits the ability to characterize different types of lesions and distinguish benign from malignant tissues. Drawbacks of our current methodology and plans for overcoming them are discussed

  14. MR imaging of the augmented and reconstructed breast

    International Nuclear Information System (INIS)

    Full text: Introduction: Various diagnostic methods are used to assess the changes in both the integrity of the implant, and the fibrous capsule of breast parenchyma. MRI has advantages over other diagnostic methods providing high tissue contrast, multi-faceted imaging and lack of ionizing radiation. What you will learn: MRI evaluation of breast augmentation approaches and their complications, MRI assessment of disease with malignant and benign characteristics in patients with breast implants, MRI assessment of breast reconstruction with autologous tissue. Discussion: Mammography after augmentation and reconstructive mammoplasty is hampered by the deformation of the breast parenchyma of the implant and the reduced compression. Postoperative scarring is also difficult to assess. MRI evaluation of implant rupture is accurate using the findings specific to it - linguine sign, teardrop sign or siliconomas. According to Gorczyca et al. MRI has a sensitivity 94% and specificity 97% in the evaluation of rupture. MRI mammography is highly sensitive - between 90 and 95%, in the detection of malignant, but it has limited specificity, which is its disadvantage. Malignant lesions can be represented as fibroadenomas, postoperative and inflammatory changes. Conclusion: Difficulties in the diagnosis of rupture of the implant, the primary and recurrent carcinoma based on clinical examination and inconclusive data from mammography and ultrasound imaging make MRI the method of choice in the evaluation of patients with breast implants

  15. Count rate studies of a box-shaped PET breast imaging system comprised of position sensitive avalanche photodiodes utilizing monte carlo simulation.

    Science.gov (United States)

    Foudray, Angela M K; Habte, Frezghi; Chinn, Garry; Zhang, Jin; Levin, Craig S

    2006-01-01

    We are investigating a high-sensitivity, high-resolution positron emission tomography (PET) system for clinical use in the detection, diagnosis and staging of breast cancer. Using conventional figures of merit, design parameters were evaluated for count rate performance, module dead time, and construction complexity. The detector system modeled comprises extremely thin position-sensitive avalanche photodiodes coupled to lutetium oxy-orthosilicate scintillation crystals. Previous investigations of detector geometries with Monte Carlo indicated that one of the largest impacts on sensitivity is local scintillation crystal density when considering systems having the same average scintillation crystal densities (same crystal packing fraction and system solid-angle coverage). Our results show the system has very good scatter and randoms rejection at clinical activity ranges ( approximately 200 muCi). PMID:17645997

  16. Experimental Study of Breast Cancer Detection Using UWB Imaging

    Directory of Open Access Journals (Sweden)

    Saleh A. Alshehri

    2011-01-01

    Full Text Available Breast cancer detection using UWB imaging is presented in this paper. The study is performed experimentally. Homogeneous breast phantom is constructed using pure petroleum jelly. The tumor is modeled using mixture of water and wheat flour. The breast fatty tissue and tumor tissue are put in breast shaped glass which mimics the skin. The dielectric properties values are comparable to previous study. Neural Network (NN was trained and tested using feature vector which is prepared by performing discrete cosine transform (DCT of the received UWB signals. Very encouraging results were obtained. Up to 100 % tumor existence detection was achieved. Tumor size and location detection rate were 91.3% and 95.6% respectively.

  17. Is general practitioner access to breast imaging safe?

    International Nuclear Information System (INIS)

    AIM: The aim of this study was to assess the consultant radiologist run open-access breast radiology service (OAR) to investigate whether the system was safe or whether cancers were being missed. METHODS: A retrospective review of the national cancer registry database to identify patients presenting with symptomatic breast cancer in the catchment area of the Royal Glamorgan Hospital (RGH) from April 2000 to April 2002 was performed. Pathology, radiology and outpatient records were reviewed to identify patients previously assessed at the RGH. RESULTS: Fifty-four patients with breast cancer were diagnosed via the OAR and 159 by the breast clinic (BC). Twelve patients with breast cancer were diagnosed after their initial presentation. Eight patients had been previously seen for benign breast lesions. Four patients had missed breast cancers (two were initially seen via the BC and two via the OAR). A significant difference in the number of cancers missed by the two referral routes was not observed (p=0.221). CONCLUSION: OAR is as accurate a means of diagnosing breast cancer as traditional rapid access BCs. Women presenting with discrete lumps with no radiological abnormality should still undergo assessment with clinical fine core-biopsy

  18. Early detection of breast cancer mass lesions by mammogram segmentation images based on texture features

    International Nuclear Information System (INIS)

    Mammography is at present one of the available method for early detection of masses or abnormalities which is related to breast cancer.The calcifications. The challenge lies in early and accurate detection to overcome the development of breast cancer that affects more and more women throughout the world. Breast cancer is diagnosed at advanced stages with the help of the digital mammogram images. Masses appear in a mammogram as fine, granular clusters, which are often difficult to identify in a raw mammogram. The incidence of breast cancer in women has increased significantly in recent years. This paper proposes a computer aided diagnostic system for the extraction of features like mass lesions in mammograms for early detection of breast cancer. The proposed technique is based on a four-step procedure: (a) the preprocessing of the image is done, (b) regions of interest (ROI) specification, (c) supervised segmentation method includes two to stages performed using the minimum distance (M D) criterion, and (d) feature extraction based on Gray level Co-occurrence matrices GLC M for the identification of mass lesions. The method suggested for the detection of mass lesions from mammogram image segmentation and analysis was tested over several images taken from A L-llwiya Hospital in Baghdad, Iraq.The proposed technique shows better results.

  19. Medical imaging and computers in the diagnosis of breast cancer

    Science.gov (United States)

    Giger, Maryellen L.

    2014-09-01

    Computer-aided diagnosis (CAD) and quantitative image analysis (QIA) methods (i.e., computerized methods of analyzing digital breast images: mammograms, ultrasound, and magnetic resonance images) can yield novel image-based tumor and parenchyma characteristics (i.e., signatures that may ultimately contribute to the design of patient-specific breast cancer management plans). The role of QIA/CAD has been expanding beyond screening programs towards applications in risk assessment, diagnosis, prognosis, and response to therapy as well as in data mining to discover relationships of image-based lesion characteristics with genomics and other phenotypes; thus, as they apply to disease states. These various computer-based applications are demonstrated through research examples from the Giger Lab.

  20. Pet imaging of estrogen receptors in breast cancer

    International Nuclear Information System (INIS)

    The development of radiopharmaceutical for imaging steroid receptors in breast cancer could have considerable clinical value because of the known relationship between the levels of steroid receptors, particularly for estrogen and progestin, and the natural history and response of this cancer to therapy. We recently reported preliminary clinical investigation of a new radiopharmaceutical, 16α-[18F]fluoro-estradiol-17β (FES), which had shown highly favorable biodistribution as an estrogen receptor ligand in animals. Twelve women undergoing preliminary evaluation for new breast masses and later confirmed to have breast cancer were studied with positron emission tomography (PET) and FES. PET-measured primary tumor uptake of the tracer was shown to have an excellent correlation with tumor estrogen receptor concentration (r = 0.96) determined by in vitro techniques. PET images demonstrated primary breast cancers, as well as several foci of axillary metastases. Additionally, one distant site of metastasis on the anterior chest wall was visualized. To further evaluate this radioligand, additional patients with breast cancer and documented osseous and soft tissue metastases have been studied prior to and after initiation of antiestrogen chemotherapy (tamoxifen). PET imaging before antiestrogen therapy showed multiple metastatic sites. After initiation of therapy, the uptake of the FES was dramatically reduced

  1. The image quality and lesion characterization of breast using automated whole-breast ultrasound: A comparison with handheld ultrasound

    International Nuclear Information System (INIS)

    Highlights: • The image quality of AWUS was comparable to that of HHUS for lesion characterization. • In only 0.5%, the poor quality of AWUSimages inhibited precise interpretations. • The HHUS was superior to AWUS in the analysis of peripherally located, irregular, non-circumscribed, or BI-RADS category 4 or 5 lesions. - Abstract: Objective: To prospectively evaluate the image quality of automated whole breast ultrasonography (AWUS) in the characterization of breast lesions compared with handheld breast ultrasonography (HHUS). Materials and methods: This prospective study included a total of 411 lesions in 209 women. All patients underwent both HHUS and AWUS prior to biopsy. An evaluation of identical image pairs of 411 lesions obtained from both modalities was performed, and the image quality of AWUS was compared with that of HHUS as a reference standard. The overall image quality was evaluated for lesion coverage, lesion conspicuity, and artifact effect using a graded score. Additionally, the factors that correlated with differences in image quality between the two modalities were analyzed. Results: In 97.1%, the image quality of AWUS was identical or superior to that of HHUS, whereas AWUS was inferior in 2.9%. In only 0.5%, the poor quality of AWUS images caused by incomplete lesion coverage and shadowing due to a contact artifact inhibited precise interpretations. The two main causes resulting in degraded AWUS image quality were blurring of the margin (83.3%) and acoustic shadowing by Cooper's ligament or improper compression pressure of the transducer (66.7%). Among various factors, peripheral location from the nipple (p = 0.01), lesion size (p = 0.02), shape descriptor (p = 0.02), and final American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) category (p = 0.001) were correlated with differences in image quality between AWUS and HHUS. Conclusion: Although the image quality of AWUS was comparable to that of HHUS for

  2. The image quality and lesion characterization of breast using automated whole-breast ultrasound: A comparison with handheld ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    An, Yeong Yi [Department of Radiology, St. Vincent' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Kim, Sung Hun, E-mail: rad-ksh@catholic.ac.kr [Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Kang, Bong Joo [Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2015-07-15

    Highlights: • The image quality of AWUS was comparable to that of HHUS for lesion characterization. • In only 0.5%, the poor quality of AWUSimages inhibited precise interpretations. • The HHUS was superior to AWUS in the analysis of peripherally located, irregular, non-circumscribed, or BI-RADS category 4 or 5 lesions. - Abstract: Objective: To prospectively evaluate the image quality of automated whole breast ultrasonography (AWUS) in the characterization of breast lesions compared with handheld breast ultrasonography (HHUS). Materials and methods: This prospective study included a total of 411 lesions in 209 women. All patients underwent both HHUS and AWUS prior to biopsy. An evaluation of identical image pairs of 411 lesions obtained from both modalities was performed, and the image quality of AWUS was compared with that of HHUS as a reference standard. The overall image quality was evaluated for lesion coverage, lesion conspicuity, and artifact effect using a graded score. Additionally, the factors that correlated with differences in image quality between the two modalities were analyzed. Results: In 97.1%, the image quality of AWUS was identical or superior to that of HHUS, whereas AWUS was inferior in 2.9%. In only 0.5%, the poor quality of AWUS images caused by incomplete lesion coverage and shadowing due to a contact artifact inhibited precise interpretations. The two main causes resulting in degraded AWUS image quality were blurring of the margin (83.3%) and acoustic shadowing by Cooper's ligament or improper compression pressure of the transducer (66.7%). Among various factors, peripheral location from the nipple (p = 0.01), lesion size (p = 0.02), shape descriptor (p = 0.02), and final American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) category (p = 0.001) were correlated with differences in image quality between AWUS and HHUS. Conclusion: Although the image quality of AWUS was comparable to that of HHUS for

  3. Reproducing 2D breast mammography images with 3D printed phantoms

    Science.gov (United States)

    Clark, Matthew; Ghammraoui, Bahaa; Badal, Andreu

    2016-03-01

    Mammography is currently the standard imaging modality used to screen women for breast abnormalities and, as a result, it is a tool of great importance for the early detection of breast cancer. Physical phantoms are commonly used as surrogates of breast tissue to evaluate some aspects of the performance of mammography systems. However, most phantoms do not reproduce the anatomic heterogeneity of real breasts. New fabrication technologies, such as 3D printing, have created the opportunity to build more complex, anatomically realistic breast phantoms that could potentially assist in the evaluation of mammography systems. The primary objective of this work is to present a simple, easily reproducible methodology to design and print 3D objects that replicate the attenuation profile observed in real 2D mammograms. The secondary objective is to evaluate the capabilities and limitations of the competing 3D printing technologies, and characterize the x-ray properties of the different materials they use. Printable phantoms can be created using the open-source code introduced in this work, which processes a raw mammography image to estimate the amount of x-ray attenuation at each pixel, and outputs a triangle mesh object that encodes the observed attenuation map. The conversion from the observed pixel gray value to a column of printed material with equivalent attenuation requires certain assumptions and knowledge of multiple imaging system parameters, such as x-ray energy spectrum, source-to-object distance, compressed breast thickness, and average breast material attenuation. A detailed description of the new software, a characterization of the printed materials using x-ray spectroscopy, and an evaluation of the realism of the sample printed phantoms are presented.

  4. Development of a Novel Breast Cancer Detector based on Improved Holography Concave Grating Imaging Spectrometer

    International Nuclear Information System (INIS)

    Breast cancer can be detected by B-mode ultrasonic imaging, X-mammography, CT imaging, and MRI. But some drawbacks existed in these methods, their applications was limited in some certain. So, a novel high resolution breast cancer detector (BCD) is developed in this paper. Meanwhile, an improved holography concave grating imaging spectrometer (HCGIS) is designed. In this HCGIS, the holography concave grating is used as the diffraction grating. Additionally, CCD with combined image acquisition (IAQ) card and the 3D scan platform are used as the spectral image acquisition component. This BCD consists of the light source unit, light-path unit, check cavity, splitting-light unit, spectrum acquisition and imaging unit, signal processing unit, computer and data analysis software unit, etc. Experimental results show that the spectral range of the novel BCD can reach 300-1000 nm, its wavelength resolution can reach 1nm, and this system uses the back-split-light technology and the splitting-light structure of holography concave grating. Compared with the other instruments of breast cancer detection, this BCD has many advantages, such as, compacter volume, simpler algorithm, faster processing speed, higher accuracy, cheaper cost and higher resolution, etc. Therefore, this BCD will have the potential values in the detection of breast disease.

  5. Simulation study comparing high-purity germanium and cadmium zinc telluride detectors for breast imaging

    International Nuclear Information System (INIS)

    We conducted simulations to compare the potential imaging performance for breast cancer detection with High-Purity Germanium (HPGe) and Cadmium Zinc Telluride (CZT) systems with 1% and 3.8% energy resolution at 140 keV, respectively. Using the Monte Carlo N-Particle (MCNP5) simulation package, we modelled both 5 mm-thick CZT and 10 mm-thick HPGe detectors with the same parallel-hole collimator for the imaging of a breast/torso phantom. Simulated energy spectra were generated, and planar images were created for various energy windows around the 140 keV photopeak. Relative sensitivity and scatter and the torso fractions were calculated along with tumour contrast and signal-to-noise ratios (SNR). Simulations showed that utilizing a ±1.25% energy window with an HPGe system better suppressed torso background and small-angle scattered photons than a comparable CZT system using a −5%/+10% energy window. Both systems provided statistically similar contrast and SNR, with HPGe providing higher relative sensitivity. Lowering the counts of HPGe images to match CZT count density still yielded equivalent contrast between HPGe and CZT. Thus, an HPGe system may provide equivalent breast imaging capability at lower injected radioactivity levels when acquiring for equal imaging time. (paper)

  6. Digital tomosynthesis: A new future for breast imaging?

    International Nuclear Information System (INIS)

    The aim of this article is to review the major limitations in current mammography and to describe how these may be addressed by digital breast tomosynthesis (DBT). DBT is a novel imaging technology in which an x-ray fan beam sweeps in an arc across the breast, producing tomographic images and enabling the production of volumetric, three-dimensional (3D) data. It can reduce tissue overlap encountered in conventional two-dimensional (2D) mammography, and thus has the potential to improve detection of breast cancer, reduce the suspicious presentations of normal tissues, and facilitate accurate differentiation of lesion types. This paper reviews the latest studies of this new technology. Issues including diagnostic efficacy, reading time, radiation dose, and level of compression; cost and new innovations are considered

  7. Economic challenges in breast imaging. A survivor's guide to success.

    Science.gov (United States)

    Feig, S A

    2000-07-01

    Most breast imaging centers today operate under financial strain. Among strategies designed to improve their bottom line, more efficient use of the radiologist's time is the most fundamental strategy and the one most likely to succeed in all breast imaging centers. Tasks performed by the radiologist that are not directly related to interpretation and consultation should be shifted to other personnel. Other strategies that may help some breast imaging centers include accepting only self-paying patients, renegotiating the hospital contract, performing more interventional procedures, and extending the hours of operation. Measures that can improve the economic efficiency of screening mammography include batch interpretation of mammograms; paperwork reduction; brief automated reports; limiting requests for previous films from other facilities to only potentially necessary cases; dedicated screening mammography examination rooms; reduction in recall rates; and, in certain circumstances, extension of breast center hours. Measures that can improve the economic efficiency of diagnostic mammography performance and interpretation include dedicated diagnostic mammography examination rooms, automated film rotators, improved scheduling, and efficient work-flow patterns for examination performance. Measures that can improve the economic efficiency of both screening and diagnostic mammography include improved triage of screening and diagnostic patients, reminder telephone calls to confirm mammography appointments, greater use of medical assistants to help the radiologists and technologists, and streamlined film library procedures and operations. Measures that can improve the economic efficiency of breast interventional procedures include preprocedure work-up, establishment of scheduling protocols, and greater involvement of technologists and medical assistants in assisting the radiologist who performs the interventional procedures. All of these methods are intended to create a

  8. Digital image analysis outperforms manual biomarker assessment in breast cancer.

    Science.gov (United States)

    Stålhammar, Gustav; Fuentes Martinez, Nelson; Lippert, Michael; Tobin, Nicholas P; Mølholm, Ida; Kis, Lorand; Rosin, Gustaf; Rantalainen, Mattias; Pedersen, Lars; Bergh, Jonas; Grunkin, Michael; Hartman, Johan

    2016-04-01

    In the spectrum of breast cancers, categorization according to the four gene expression-based subtypes 'Luminal A,' 'Luminal B,' 'HER2-enriched,' and 'Basal-like' is the method of choice for prognostic and predictive value. As gene expression assays are not yet universally available, routine immunohistochemical stains act as surrogate markers for these subtypes. Thus, congruence of surrogate markers and gene expression tests is of utmost importance. In this study, 3 cohorts of primary breast cancer specimens (total n=436) with up to 28 years of survival data were scored for Ki67, ER, PR, and HER2 status manually and by digital image analysis (DIA). The results were then compared for sensitivity and specificity for the Luminal B subtype, concordance to PAM50 assays in subtype classification and prognostic power. The DIA system used was the Visiopharm Integrator System. DIA outperformed manual scoring in terms of sensitivity and specificity for the Luminal B subtype, widely considered the most challenging distinction in surrogate subclassification, and produced slightly better concordance and Cohen's κ agreement with PAM50 gene expression assays. Manual biomarker scores and DIA essentially matched each other for Cox regression hazard ratios for all-cause mortality. When the Nottingham combined histologic grade (Elston-Ellis) was used as a prognostic surrogate, stronger Spearman's rank-order correlations were produced by DIA. Prognostic value of Ki67 scores in terms of likelihood ratio χ(2) (LR χ(2)) was higher for DIA that also added significantly more prognostic information to the manual scores (LR-Δχ(2)). In conclusion, the system for DIA evaluated here was in most aspects a superior alternative to manual biomarker scoring. It also has the potential to reduce time consumption for pathologists, as many of the steps in the workflow are either automatic or feasible to manage without pathological expertise. PMID:26916072

  9. A multi-image approach to CADx of breast cancer with integration into PACS

    Science.gov (United States)

    Elter, Matthias; Wittenberg, Thomas; Schulz-Wendtland, Rüdiger; Deserno, Thomas M.

    2009-02-01

    While screening mammography is accepted as the most adequate technique for the early detection of breast cancer, its low positive predictive value leads to many breast biopsies performed on benign lesions. Therefore, we have previously developed a knowledge-based system for computer-aided diagnosis (CADx) of mammographic lesions. It supports the radiologist in the discrimination of benign and malignant lesions. So far, our approach operates on the lesion level and employs the paradigm of content-based image retrieval (CBIR). Similar lesions with known diagnosis are retrieved automatically from a library of references. However, radiologists base their diagnostic decisions on additional resources, such as related mammographic projections, other modalities (e.g. ultrasound, MRI), and clinical data. Nonetheless, most CADx systems disregard the relation between the craniocaudal (CC) and mediolateral-oblique (MLO) views of conventional mammography. Therefore, we extend our approach to the full case level: (i) Multi-frame features are developed that jointly describe a lesion in different views of mammography. Taking into account the geometric relation between different images, these features can also be extracted from multi-modal data; (ii) the CADx system architecture is extended appropriately; (iii) the CADx system is integrated into the radiology information system (RIS) and the picture archiving and communication system (PACS). Here, the framework for image retrieval in medical applications (IRMA) is used to support access to the patient's health care record. Of particular interest is the application of the proposed CADx system to digital breast tomosynthesis (DBT), which has the potential to succeed digital mammography as the standard technique for breast cancer screening. The proposed system is a natural extension of CADx approaches that integrate only two modalities. However, we are still collecting a large enough database of breast lesions with images from

  10. Immunophenotyping invasive breast cancer: paving the road for molecular imaging

    International Nuclear Information System (INIS)

    Mammographic population screening in The Netherlands has increased the number of breast cancer patients with small and non-palpable breast tumors. Nevertheless, mammography is not ultimately sensitive and specific for distinct subtypes. Molecular imaging with targeted tracers might increase specificity and sensitivity of detection. Because development of new tracers is labor-intensive and costly, we searched for the smallest panel of tumor membrane markers that would allow detection of the wide spectrum of invasive breast cancers. Tissue microarrays containing 483 invasive breast cancers were stained by immunohistochemistry for a selected set of membrane proteins known to be expressed in breast cancer. The combination of highly tumor-specific markers glucose transporter 1 (GLUT1), epidermal growth factor receptor (EGFR), insulin-like growth factor-1 receptor (IGF1-R), human epidermal growth factor receptor 2 (HER2), hepatocyte growth factor receptor (MET), and carbonic anhydrase 9 (CAIX) 'detected' 45.5% of tumors, especially basal/triple negative and HER2-driven ductal cancers. Addition of markers with a 2-fold tumor-to-normal ratio increased the detection rate to 98%. Including only markers with >3 fold tumor-to-normal ratio (CD44v6) resulted in an 80% detection rate. The detection rate of the panel containing both tumor-specific and less tumor-specific markers was not dependent on age, tumor grade, tumor size, or lymph node status. In search of the minimal panel of targeted probes needed for the highest possible detection rate, we showed that 80% of all breast cancers express at least one of a panel of membrane markers (CD44v6, GLUT1, EGFR, HER2, and IGF1-R) that may therefore be suitable for molecular imaging strategies. This study thereby serves as a starting point for further development of a set of antibody-based optical tracers with a high breast cancer detection rate

  11. Immunophenotyping invasive breast cancer: paving the road for molecular imaging

    Directory of Open Access Journals (Sweden)

    Vermeulen Jeroen F

    2012-06-01

    Full Text Available Abstract Background Mammographic population screening in The Netherlands has increased the number of breast cancer patients with small and non-palpable breast tumors. Nevertheless, mammography is not ultimately sensitive and specific for distinct subtypes. Molecular imaging with targeted tracers might increase specificity and sensitivity of detection. Because development of new tracers is labor-intensive and costly, we searched for the smallest panel of tumor membrane markers that would allow detection of the wide spectrum of invasive breast cancers. Methods Tissue microarrays containing 483 invasive breast cancers were stained by immunohistochemistry for a selected set of membrane proteins known to be expressed in breast cancer. Results The combination of highly tumor-specific markers glucose transporter 1 (GLUT1, epidermal growth factor receptor (EGFR, insulin-like growth factor-1 receptor (IGF1-R, human epidermal growth factor receptor 2 (HER2, hepatocyte growth factor receptor (MET, and carbonic anhydrase 9 (CAIX 'detected' 45.5% of tumors, especially basal/triple negative and HER2-driven ductal cancers. Addition of markers with a 2-fold tumor-to-normal ratio increased the detection rate to 98%. Including only markers with >3 fold tumor-to-normal ratio (CD44v6 resulted in an 80% detection rate. The detection rate of the panel containing both tumor-specific and less tumor-specific markers was not dependent on age, tumor grade, tumor size, or lymph node status. Conclusions In search of the minimal panel of targeted probes needed for the highest possible detection rate, we showed that 80% of all breast cancers express at least one of a panel of membrane markers (CD44v6, GLUT1, EGFR, HER2, and IGF1-R that may therefore be suitable for molecular imaging strategies. This study thereby serves as a starting point for further development of a set of antibody-based optical tracers with a high breast cancer detection rate.

  12. Design of a CZT based BreastSPECT system

    International Nuclear Information System (INIS)

    A high-resolution SPECT instrument dedicated to breast imaging has been designed incorporating arrays of collimated Cadmium-Zinc-Telluride (CZT) detectors tiled on either a cylindrical surface or a hemispherical surface surrounding the breast. The performance characteristics of a three-segment rotating parallel-hole collimator as well as a stationary multiple pin-hole collimator were considered for the cylindrical system. A stationary multiple pin-hole collimated system was also considered for the hemispherical design. Monte Carlo studies suggest that at almost equal spatial resolution of 0.5 cm, the cylindrical design with parallel-hole collimator would have an approximately a factor of two higher geometrical efficiency than the hemispherical pin-hole collimated system including effects of attenuation in the breast. However, whereas the parallel-hole collimator must be rotated to acquire data from multiple angles of view, the pin-hole version has the advantage of recording data from 112 views in a stationary mode. Monte Carlo studies of filtered backprojections as well as a Bayesian reconstruction approach including attenuation and scatter within the breast, where the breast was modeled as a 15 cm hemisphere of uniform activity distribution containing three spherical lesions of diameters 1.0 cm, 0.7 cm and 0.5 cm respectively suggest that the 0.5 cm could be detected with either design in a one-hour SPECT study assuming a 10:1 tumor to background ratio. The authors conclude that a high resolution Breast SPECT instrument where the resolution is limited to about 0.5 cm is viable with CZT detectors

  13. Design of a CZT based BreastSPECT system

    Energy Technology Data Exchange (ETDEWEB)

    Singh, M.; Mumcuoglu, E. [Univ. of Southern California, Los Angeles, CA (United States)

    1998-06-01

    A high-resolution SPECT instrument dedicated to breast imaging has been designed incorporating arrays of collimated Cadmium-Zinc-Telluride (CZT) detectors tiled on either a cylindrical surface or a hemispherical surface surrounding the breast. The performance characteristics of a three-segment rotating parallel-hole collimator as well as a stationary multiple pin-hole collimator were considered for the cylindrical system. A stationary multiple pin-hole collimated system was also considered for the hemispherical design. Monte Carlo studies suggest that at almost equal spatial resolution of 0.5 cm, the cylindrical design with parallel-hole collimator would have an approximately a factor of two higher geometrical efficiency than the hemispherical pin-hole collimated system including effects of attenuation in the breast. However, whereas the parallel-hole collimator must be rotated to acquire data from multiple angles of view, the pin-hole version has the advantage of recording data from 112 views in a stationary mode. Monte Carlo studies of filtered backprojections as well as a Bayesian reconstruction approach including attenuation and scatter within the breast, where the breast was modeled as a 15 cm hemisphere of uniform activity distribution containing three spherical lesions of diameters 1.0 cm, 0.7 cm and 0.5 cm respectively suggest that the 0.5 cm could be detected with either design in a one-hour SPECT study assuming a 10:1 tumor to background ratio. The authors conclude that a high resolution Breast SPECT instrument where the resolution is limited to about 0.5 cm is viable with CZT detectors.

  14. Estimation of breast density: An adaptive moment preserving method for segmentation of fibroglandular tissue in breast magnetic resonance images

    International Nuclear Information System (INIS)

    Purpose: Breast density has been found to be a potential indicator for breast cancer risk. The estimation of breast density can be seen as a segmentation problem on fibroglandular tissues from a breast magnetic resonance image. The classic moment preserving is a thresholding method, which can be applied to determine an appropriate threshold value for fibroglandular tissue segmentation. Methods: This study proposed an adaptive moment preserving method, which combines the classic moment preserving and a thresholding adjustment method. The breast MR images are firstly performed to extract the fibroglandular tissue from the breast tissue. The next step is to obtain the areas of the fibroglandular tissue and the whole breast tissue. Finally, breast density can be estimated for the given breast. Results: The Friedman test shows that the qualities of segmentation are insignificant with p < 0.000 and Friedman chi-squared = 1116.12. The Friedman test shows that there would be significant differences in the sum of the ranks of at least one segmentation method. Average ranks indicate that the performance of the four methods is ranked as adaptive moment preserving, fuzzy c-means, moment preserving, and Kapur's method in order. Among the four methods, adaptive moment preserving also achieves the minimum values of MAE and RMSE with 9.2 and 12. Conclusion: This study has verified that the proposed adaptive moment preserving can identify and segment the fibroglandular tissues from the 2D breast MR images and estimate the degrees of breast density.

  15. Quantitative phase imaging of Breast cancer cell based on SLIM

    Science.gov (United States)

    Wu, Huaqin; Li, Zhifang; Li, Hui; Wu, Shulian

    2016-02-01

    We illustrated a novel optical microscopy technique to observe cell dynamics via spatial light interference microscopy (SLIM). SLIM combines Zemike's phase contrast microscopy and Gabor's holography. When the light passes through the transparent specimens, it could render high contrast intensity and record the phase information from the object. We reconstructed the Breast cancer cell phase image by SLIM and the reconstruction algorithm. Our investigation showed that SLIM has the ability to achieve the quantitative phase imaging (QPI).

  16. An infrared image based methodology for breast lesions screening

    Science.gov (United States)

    Morais, K. C. C.; Vargas, J. V. C.; Reisemberger, G. G.; Freitas, F. N. P.; Oliari, S. H.; Brioschi, M. L.; Louveira, M. H.; Spautz, C.; Dias, F. G.; Gasperin, P.; Budel, V. M.; Cordeiro, R. A. G.; Schittini, A. P. P.; Neto, C. D.

    2016-05-01

    The objective of this paper is to evaluate the potential of utilizing a structured methodology for breast lesions screening, based on infrared imaging temperature measurements of a healthy control group to establish expected normality ranges, and of breast cancer patients, previously diagnosed through biopsies of the affected regions. An analysis of the systematic error of the infrared camera skin temperature measurements was conducted in several different regions of the body, by direct comparison to high precision thermistor temperature measurements, showing that infrared camera temperatures are consistently around 2 °C above the thermistor temperatures. Therefore, a method of conjugated gradients is proposed to eliminate the infrared camera direct temperature measurement imprecision, by calculating the temperature difference between two points to cancel out the error. The method takes into account the human body approximate bilateral symmetry, and compares measured dimensionless temperature difference values (Δ θ bar) between two symmetric regions of the patient's breast, that takes into account the breast region, the surrounding ambient and the individual core temperatures, and doing so, the results interpretation for different individuals become simple and non subjective. The range of normal whole breast average dimensionless temperature differences for 101 healthy individuals was determined, and admitting that the breasts temperatures exhibit a unimodal normal distribution, the healthy normal range for each region was considered to be the dimensionless temperature difference plus/minus twice the standard deviation of the measurements, Δ θ bar ‾ + 2σ Δ θ bar ‾ , in order to represent 95% of the population. Forty-seven patients with previously diagnosed breast cancer through biopsies were examined with the method, which was capable of detecting breast abnormalities in 45 cases (96%). Therefore, the conjugated gradients method was considered effective

  17. Breast imaging findings in women with BRCA1- and BRCA2-associated breast carcinoma

    International Nuclear Information System (INIS)

    AIM: To document the breast imaging findings of women with BRCA1 and BRCA2-associated breast carcinoma. MATERIALS AND METHODS: Family history clinic records identified 18 BRCA1 and 10 BRCA2 cases who collectively were diagnosed with 27 invasive breast carcinomas and four ductal carcinoma in situ (DCIS) lesions. All underwent pre-operative imaging (29 mammogram and 22 ultrasound examinations). All invasive BRCA-associated breast carcinoma cases were compared with age-matched cases of sporadic breast carcinoma. RESULTS: Within the BRCA cases the age range was 26-62 years, mean 36 years. Two mammograms were normal and 27 (93%) abnormal. The most common mammographic features were defined mass (63%) and microcalcifications (37%). Thirty-four percent of women had a dense mammographic pattern, 59% mixed and 7% fatty. Ultrasound was performed in 22 patients and in 21 (95%) indicated a mass. This was classified as benign in 24%, indeterminate in 29% and malignant in 48%. Mammograms of BRCA1-associated carcinomas more frequently showed a defined mass compared with BRCA2-associated carcinomas, 72 versus 36% (73% control group) whilst mammograms of BRCA2-associated carcinomas more frequently showed microcalcification, 73 versus 12% (8% control group; p<0.001). Thirty-six percent of the BRCA2-associated carcinomas were pure DCIS while none of the BRCA1 associated carcinomas were pure DCIS (p=0.004). Of those patients undergoing regular mammographic screening, 100% of BRCA2-associated carcinomas were detected compared with 75% of BRCA1-associated carcinomas. CONCLUSION: These data suggest that the imaging findings of BRCA1 and BRCA2-associated carcinomas differ from each other and from age-matched cases of sporadic breast carcinoma

  18. MR imaging of brachial plexopathy in breast cancer patients without palpable recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Lingawi, S.S. (Department of Radiology, St. Paul' s Hospital, Vancouver, BC (Canada) Vancouver General Hospital, University of British Columbia, Vancouver, BC (Canada) Radiology Department, Vancouver General Hospital, BC (Canada)); Bilbey, J.H. (Department of Radiology, St. Paul' s Hospital, Vancouver, BC (Canada)); Munk, P.L.; Marchinkow, L.O. (Vancouver General Hospital, University of British Columbia, Vancouver, BC (Canada)); Poon, P.Y. (Department of Diagnostic Imaging, British Columbia Cancer Agency, Vancouver, BC (Canada)); Allan, B.M. (Department of Neurology, Vancouver Hospital, Vancouver, BC (Canada)); Olivotto, I.A. (Division of Radiation Oncology, British Columbia Cancer Agency, Vancouver, BC (Canada))

    1999-06-01

    Objective. To investigate the role of MR imaging in detecting brachial plexus (BP) abnormalities in breast cancer patients with plexopathy but without palpable masses.Design. MR imaging of the BP was performed on 26 breast cancer patients with brachial plexopathy without palpable regional masses, using 0.5 T and 1.5 T imaging systems. Findings were correlated with the clinical diagnoses.Patients. Twenty-six patients with brachial plexopathy and history of breast cancer were enrolled in the study. All patients presented with plexopathy symptoms. Fourteen patients were positive and 12 patients were indeterminate for BP metastasis according to clinical criteria.Results and conclusion. MR imaging demonstrated masses involving the BP representing metastases in two patients. Nine patients had other regional abnormalities with a normal brachial plexus. It is concluded that MR imaging is useful in the assessment and direction of therapy of brachial plexopathy in breast cancer patients by detecting both metastases to the BP as well as other abnormalities, unrelated to the BP, which may explain the patient's symptoms. (orig.) With 4 figs., 1 tab., 18 refs.

  19. Dynamic infrared imaging in identification of breast cancer tissue with combined image processing and frequency analysis.

    Science.gov (United States)

    Joro, R; Lääperi, A-L; Soimakallio, S; Järvenpää, R; Kuukasjärvi, T; Toivonen, T; Saaristo, R; Dastidar, P

    2008-01-01

    Five combinations of image-processing algorithms were applied to dynamic infrared (IR) images of six breast cancer patients preoperatively to establish optimal enhancement of cancer tissue before frequency analysis. mid-wave photovoltaic (PV) IR cameras with 320x254 and 640x512 pixels were used. The signal-to-noise ratio and the specificity for breast cancer were evaluated with the image-processing combinations from the image series of each patient. Before image processing and frequency analysis the effect of patient movement was minimized with a stabilization program developed and tested in the study by stabilizing image slices using surface markers set as measurement points on the skin of the imaged breast. A mathematical equation for superiority value was developed for comparison of the key ratios of the image-processing combinations. The ability of each combination to locate the mammography finding of breast cancer in each patient was compared. Our results show that data collected with a 640x512-pixel mid-wave PV camera applying image-processing methods optimizing signal-to-noise ratio, morphological image processing and linear image restoration before frequency analysis possess the greatest superiority value, showing the cancer area most clearly also in the match centre of the mammography estimation. PMID:18666012

  20. Towards breast tomography with synchrotron radiation at Elettra: first images

    Science.gov (United States)

    Longo, R.; Arfelli, F.; Bellazzini, R.; Bottigli, U.; Brez, A.; Brun, F.; Brunetti, A.; Delogu, P.; Di Lillo, F.; Dreossi, D.; Fanti, V.; Fedon, C.; Golosio, B.; Lanconelli, N.; Mettivier, G.; Minuti, M.; Oliva, P.; Pinchera, M.; Rigon, L.; Russo, P.; Sarno, A.; Spandre, G.; Tromba, G.; Zanconati, F.

    2016-02-01

    The aim of the SYRMA-CT collaboration is to set-up the first clinical trial of phase-contrast breast CT with synchrotron radiation (SR). In order to combine high image quality and low delivered dose a number of innovative elements are merged: a CdTe single photon counting detector, state-of-the-art CT reconstruction and phase retrieval algorithms. To facilitate an accurate exam optimization, a Monte Carlo model was developed for dose calculation using GEANT4. In this study, high isotropic spatial resolution (120 μm)3 CT scans of objects with dimensions and attenuation similar to a human breast were acquired, delivering mean glandular doses in the range of those delivered in clinical breast CT (5-25 mGy). Due to the spatial coherence of the SR beam and the long distance between sample and detector, the images contain, not only absorption, but also phase information from the samples. The application of a phase-retrieval procedure increases the contrast-to-noise ratio of the tomographic images, while the contrast remains almost constant. After applying the simultaneous algebraic reconstruction technique to low-dose phase-retrieved data sets (about 5 mGy) with a reduced number of projections, the spatial resolution was found to be equal to filtered back projection utilizing a four fold higher dose, while the contrast-to-noise ratio was reduced by 30%. These first results indicate the feasibility of clinical breast CT with SR.

  1. Breast MR imaging in women at high-risk of breast cancer. Is something changing in early breast cancer detection?

    International Nuclear Information System (INIS)

    In the last few years, several papers have addressed the introduction of contrast-enhanced MR imaging for screening women at high risk for breast cancer. Taking in consideration five prospective studies, on 3,571 screened women with hereditary predisposition to the disease and 9,652 rounds, we found that 168 patients were diagnosed with breast cancer (155 screen-detected, eight interval, and five cancers excluded from analysis) with a detection rate per year of 1.7%. These cancers were small (49% equal to or less than 10 mm in diameter) but aggressive, 82% being invasive and 49% with histologic grade 3; however, only 19% of these invasive cancers were associated with nodal involvement. The pooled sensitivity was 16% for clinical breast examination, 40% for mammography, 43% for ultrasound, and 81% for MR. The positive predictive value (calculated on the basis of the number of invasive diagnostic procedures due to false positives) was 33%, 47%, 18%, and 53%, respectively. Aim of the present article is to present the historical development of MR imaging of breast tumors that made this application theoretically and technically possible, to explain what strategic problems we face in the presence of a hereditary predisposition to the disease, to review the main results of the published studies, and to outline open problems and future perspectives. (orig.)

  2. Automated analysis of image mammogram for breast cancer diagnosis

    Science.gov (United States)

    Nurhasanah, Sampurno, Joko; Faryuni, Irfana Diah; Ivansyah, Okto

    2016-03-01

    Medical imaging help doctors in diagnosing and detecting diseases that attack the inside of the body without surgery. Mammogram image is a medical image of the inner breast imaging. Diagnosis of breast cancer needs to be done in detail and as soon as possible for determination of next medical treatment. The aim of this work is to increase the objectivity of clinical diagnostic by using fractal analysis. This study applies fractal method based on 2D Fourier analysis to determine the density of normal and abnormal and applying the segmentation technique based on K-Means clustering algorithm to image abnormal for determine the boundary of the organ and calculate the area of organ segmentation results. The results show fractal method based on 2D Fourier analysis can be used to distinguish between the normal and abnormal breast and segmentation techniques with K-Means Clustering algorithm is able to generate the boundaries of normal and abnormal tissue organs, so area of the abnormal tissue can be determined.

  3. Roles of biologic breast tissue composition and quantitative image analysis of mammographic images in breast tumor characterization

    Science.gov (United States)

    Drukker, Karen; Giger, Maryellen L.; Duewer, Fred; Malkov, Serghei; Flowers, Christopher I.; Joe, Bonnie; Kerlikowske, Karla; Drukteinis, Jennifer S.; Shepherd, John

    2014-03-01

    Purpose. Investigate whether knowledge of the biologic image composition of mammographic lesions provides imagebased biomarkers above and beyond those obtainable from quantitative image analysis (QIA) of X-ray mammography. Methods. The dataset consisted of 45 in vivo breast lesions imaged with the novel 3-component breast (3CB) imaging technique based on dual-energy mammography (15 malignant, 30 benign diagnoses). The 3CB composition measures of water, lipid, and protein thicknesses were assessed and mathematical descriptors, `3CB features', were obtained for the lesions and their periphery. The raw low-energy mammographic images were analyzed with an established in-house QIA method obtaining `QIA features' describing morphology and texture. We investigated the correlation within the `3CB features', within the `QIA features', and between the two. In addition, the merit of individual features in the distinction between malignant and benign lesions was assessed. Results. Whereas many descriptors within the `3CB features' and `QIA features' were, often by design, highly correlated, correlation between descriptors of the two feature groups was much weaker (maximum absolute correlation coefficient 0.58, pappeared equally well-suited for the distinction between malignant and benign lesions, with maximum area under the ROC curve 0.71 for a protein feature (3CB) and 0.71 for a texture feature (QIA). Conclusions. In this pilot study analyzing the new 3CB imaging modality, knowledge of breast tissue composition appeared additive in combination with existing mammographic QIA methods for the distinction between benign and malignant lesions.

  4. Clinical Outcome of Magnetic Resonance Imaging-Detected Additional Lesions in Breast Cancer Patients

    OpenAIRE

    Ha, Gi-Won; Yi, Mi Suk; Lee, Byoung Kil; Youn, Hyun Jo; Jung, Sung Hoo

    2011-01-01

    Purpose The aim of this study was to investigate the clinical outcome of additional breast lesions identified with breast magnetic resonance imaging (MRI) in breast cancer patients. Methods A total of 153 patients who underwent breast MRI between July 2006 and March 2008 were retrospectively reviewed. Thirty-three patients (21.6&) were recommended for second-look ultrasound (US) for further characterization of additional lesions detected on breast MRI and these patients constituted our study ...

  5. Breast image feature learning with adaptive deconvolutional networks

    Science.gov (United States)

    Jamieson, Andrew R.; Drukker, Karen; Giger, Maryellen L.

    2012-03-01

    Feature extraction is a critical component of medical image analysis. Many computer-aided diagnosis approaches employ hand-designed, heuristic lesion extracted features. An alternative approach is to learn features directly from images. In this preliminary study, we explored the use of Adaptive Deconvolutional Networks (ADN) for learning high-level features in diagnostic breast mass lesion images with potential application to computer-aided diagnosis (CADx) and content-based image retrieval (CBIR). ADNs (Zeiler, et. al., 2011), are recently-proposed unsupervised, generative hierarchical models that decompose images via convolution sparse coding and max pooling. We trained the ADNs to learn multiple layers of representation for two breast image data sets on two different modalities (739 full field digital mammography (FFDM) and 2393 ultrasound images). Feature map calculations were accelerated by use of GPUs. Following Zeiler et. al., we applied the Spatial Pyramid Matching (SPM) kernel (Lazebnik, et. al., 2006) on the inferred feature maps and combined this with a linear support vector machine (SVM) classifier for the task of binary classification between cancer and non-cancer breast mass lesions. Non-linear, local structure preserving dimension reduction, Elastic Embedding (Carreira-Perpiñán, 2010), was then used to visualize the SPM kernel output in 2D and qualitatively inspect image relationships learned. Performance was found to be competitive with current CADx schemes that use human-designed features, e.g., achieving a 0.632+ bootstrap AUC (by case) of 0.83 [0.78, 0.89] for an ultrasound image set (1125 cases).

  6. Magnetic Resonance Imaging (MRI and Spectroscopy (MRS in Breast Cancer

    Directory of Open Access Journals (Sweden)

    Uma Sharma

    2008-01-01

    Full Text Available Breast cancer is a major health problem in women and early detection is of prime importance. Breast magnetic resonance imaging (MRI provides both physical and physiologic tissue features that are useful in discriminating malignant from benign lesions. Contrast enhanced MRI is valuable for diagnosis of small tumors in dense breast and the structural and kinetic parameters improved the specificity of diagnosing benign from malignant lesions. It is a complimentary modality for preoperative staging, to follow response to therapy, to detect recurrences and for screening high risk women. Diffusion, perfusion and MR elastography have been applied to breast lesion characterization and show promise.In-vivo MR spectroscopy (MRS is a valuable method to obtain the biochemical status of normal and diseased tissues. Malignant tissues contain high concentration of choline containing compounds that can be used as a biochemical marker. MRS helps to increase the specificity of MRI in lesions larger than 1cm and to monitor the tumor response. Various MR techniques show promise primarily as adjunct to the existing standard detection techniques, and its acceptability as a screening method will increase if specificity can be improved. This review presents the progress made in different MRI and MRS techniques in breast cancer management.

  7. Breast

    International Nuclear Information System (INIS)

    Ultrasound is not an efficacious screening modality to detect early-stage breast malignancy in a clinically unremarkable population of women. Computed body tomography is similarly not practical for screening because of slice thickness and partial volume averaging, a higher radiation dose than modern mammography, and the lack of availability of such units for such a high throughput requirement. Nevertheless, these two imaging modalities can be very useful in management to guide the least invasive and efficacious treatment of the patient. X-ray mammography remains the principal imaging modality in the search for breast malignancy, but ultrasound is the single most important second study in the diagnostic evaluation of the breast. The combined use of these techniques and the ability to perform guided aspiration and localization procedures can result in a reduction in the surgical removal of benign cysts and reduction in the amount of tissue volume required if excision becomes necessary

  8. Breast augmentation and reconstructive surgery: MR imaging of implant rupture and malignancy

    International Nuclear Information System (INIS)

    The purpose of this study was to assess the diagnostic accuracy of MRI in detecting prosthesis integrity and malignancy after breast augmentation and reconstruction. Forty-one implants in 25 patients were analyzed by MRI before surgical removal. Imaging results were compared with ex vivo findings. Magnetic resonance imaging of the breast was performed on a 1.5-T system using a dedicated surface breast coil. Axial and sagittal T2-weighted fast spin-echo as well as dynamic contrast-enhanced T1-weighted gradient-recalled-echo sequences were acquired. The linguine sign indicating collapse of the silicone shell or siliconomas indicating free silicone proved implant rupture, whereas early focal contrast enhancement of a lesion was suspicious for malignancy. The sensitivity for detection of implant rupture was 86.7% with a specificity of 88.5%. The positive and negative predictive values were 81.3 and 92.0%, respectively. The linguine sign as a predictor of intracapsular implant rupture had a sensitivity of 80% with a specificity of 96.2%. Magnetic resonance imaging revealed two lesions with suspicious contrast enhancement (one carcinoma, one extra-abdominal fibromatosis). Magnetic resonance imaging is a reliable and reproducible technique for diagnosing both implant rupture and malignant lesions in women after breast augmentation and reconstruction. (orig.)

  9. Towards Quantification of Functional Breast Images Using Dedicated SPECT With Non-Traditional Acquisition Trajectories.

    Science.gov (United States)

    Perez, Kristy L; Cutler, Spencer J; Madhav, Priti; Tornai, Martin P

    2011-10-01

    Quantification of radiotracer uptake in breast lesions can provide valuable information to physicians in deciding patient care or determining treatment efficacy. Physical processes (e.g., scatter, attenuation), detector/collimator characteristics, sampling and acquisition trajectories, and reconstruction artifacts contribute to an incorrect measurement of absolute tracer activity and distribution. For these experiments, a cylinder with three syringes of varying radioactivity concentration, and a fillable 800 mL breast with two lesion phantoms containing aqueous (99m)Tc pertechnetate were imaged using the SPECT sub-system of the dual-modality SPECT-CT dedicated breast scanner. SPECT images were collected using a compact CZT camera with various 3D acquisitions including vertical axis of rotation, 30° tilted, and complex sinusoidal trajectories. Different energy windows around the photopeak were quantitatively compared, along with appropriate scatter energy windows, to determine the best quantification accuracy after attenuation and dual-window scatter correction. Measured activity concentrations in the reconstructed images for syringes with greater than 10 µCi /mL corresponded to within 10% of the actual dose calibrator measured activity concentration for ±4% and ±8% photopeak energy windows. The same energy windows yielded lesion quantification results within 10% in the breast phantom as well. Results for the more complete complex sinsusoidal trajectory are similar to the simple vertical axis acquisition, and additionally allows both anterior chest wall sampling, no image distortion, and reasonably accurate quantification. PMID:22262925

  10. Medical imaging systems

    Science.gov (United States)

    Frangioni, John V

    2013-06-25

    A medical imaging system provides simultaneous rendering of visible light and diagnostic or functional images. The system may be portable, and may include adapters for connecting various light sources and cameras in open surgical environments or laparascopic or endoscopic environments. A user interface provides control over the functionality of the integrated imaging system. In one embodiment, the system provides a tool for surgical pathology.

  11. Magnetic Resonance Imaging of Breast Cancer and Correlation with Prognostic Factors

    International Nuclear Information System (INIS)

    Background: Prognostic factors of breast cancer have been used for the prediction of clinical outcome or selection of patients for complementary treatment. Some of the imaging features of breast cancer, e.g. magnetic resonance imaging (MRI), are associated with these prognostic factors. Purpose: To evaluate the relationship between dynamic enhanced MR features and prognostic factors of clinical outcome of breast cancer. Material and Methods: A total of 136 patients with 151 breast cancers underwent 1.5T dynamic MR imaging with the use of a dynamic T1-weighted three-dimensional fast low-angle shot (FLASH) subtraction imaging technique. Morphological and kinetic analyses of MR features were evaluated using the American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS) MRI lexicon. Pathological prognostic factors were correlated with MR imaging characteristics, including tumor size, histological grade, lymph node status, expression of estrogen receptor (ER), expression of progesterone receptor (PR), expression of c-erbB2, determination of Ki-67 index, and microvascular density (MVD), using univariate and multivariate statistical analyses. Results: Based on univariate and multivariate analyses, spiculated tumor margins correlated significantly with lower histological grade (I-II) and positive PR expression. Rim enhancement was significantly correlated with high histological grade, presence of axillary lymph node metastasis, large tumor size, increased Ki-67 index, and increased MVD. Early peak enhancement, as seen on the first scan after contrast medium injection, was correlated with negative ER expression. Conclusion: The presence of a lesion with a spiculated margin may predict a relatively good prognosis, and the presence of a lesion with rim enhancement may predict a relatively poor prognosis

  12. Magnetic resonance imaging texture analysis classification of primary breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Waugh, S.A.; Lerski, R.A. [Ninewells Hospital and Medical School, Department of Medical Physics, Dundee (United Kingdom); Purdie, C.A.; Jordan, L.B. [Ninewells Hospital and Medical School, Department of Pathology, Dundee (United Kingdom); Vinnicombe, S. [University of Dundee, Division of Imaging and Technology, Ninewells Hospital and Medical School, Dundee (United Kingdom); Martin, P. [Ninewells Hospital and Medical School, Department of Clinical Radiology, Dundee (United Kingdom); Thompson, A.M. [University of Texas MD Anderson Cancer Center, Department of Surgical Oncology, Houston, TX (United States)

    2016-02-15

    Patient-tailored treatments for breast cancer are based on histological and immunohistochemical (IHC) subtypes. Magnetic Resonance Imaging (MRI) texture analysis (TA) may be useful in non-invasive lesion subtype classification. Women with newly diagnosed primary breast cancer underwent pre-treatment dynamic contrast-enhanced breast MRI. TA was performed using co-occurrence matrix (COM) features, by creating a model on retrospective training data, then prospectively applying to a test set. Analyses were blinded to breast pathology. Subtype classifications were performed using a cross-validated k-nearest-neighbour (k = 3) technique, with accuracy relative to pathology assessed and receiver operator curve (AUROC) calculated. Mann-Whitney U and Kruskal-Wallis tests were used to assess raw entropy feature values. Histological subtype classifications were similar across training (n = 148 cancers) and test sets (n = 73 lesions) using all COM features (training: 75 %, AUROC = 0.816; test: 72.5 %, AUROC = 0.823). Entropy features were significantly different between lobular and ductal cancers (p < 0.001; Mann-Whitney U). IHC classifications using COM features were also similar for training and test data (training: 57.2 %, AUROC = 0.754; test: 57.0 %, AUROC = 0.750). Hormone receptor positive and negative cancers demonstrated significantly different entropy features. Entropy features alone were unable to create a robust classification model. Textural differences on contrast-enhanced MR images may reflect underlying lesion subtypes, which merits testing against treatment response. (orig.)

  13. Magnetic resonance imaging texture analysis classification of primary breast cancer

    International Nuclear Information System (INIS)

    Patient-tailored treatments for breast cancer are based on histological and immunohistochemical (IHC) subtypes. Magnetic Resonance Imaging (MRI) texture analysis (TA) may be useful in non-invasive lesion subtype classification. Women with newly diagnosed primary breast cancer underwent pre-treatment dynamic contrast-enhanced breast MRI. TA was performed using co-occurrence matrix (COM) features, by creating a model on retrospective training data, then prospectively applying to a test set. Analyses were blinded to breast pathology. Subtype classifications were performed using a cross-validated k-nearest-neighbour (k = 3) technique, with accuracy relative to pathology assessed and receiver operator curve (AUROC) calculated. Mann-Whitney U and Kruskal-Wallis tests were used to assess raw entropy feature values. Histological subtype classifications were similar across training (n = 148 cancers) and test sets (n = 73 lesions) using all COM features (training: 75 %, AUROC = 0.816; test: 72.5 %, AUROC = 0.823). Entropy features were significantly different between lobular and ductal cancers (p < 0.001; Mann-Whitney U). IHC classifications using COM features were also similar for training and test data (training: 57.2 %, AUROC = 0.754; test: 57.0 %, AUROC = 0.750). Hormone receptor positive and negative cancers demonstrated significantly different entropy features. Entropy features alone were unable to create a robust classification model. Textural differences on contrast-enhanced MR images may reflect underlying lesion subtypes, which merits testing against treatment response. (orig.)

  14. Magnetic Resonance Spectroscopic Imaging (MRSI Study of Breast Cancer

    Directory of Open Access Journals (Sweden)

    K. B. Ashok

    2011-05-01

    Full Text Available Background: Breast cancer is the fifth most common cause of cancer death worldwide and most serious form of neoplastic diseases in both developed and developing countries. Mammography and ultrasound are the most often used screening methods in breast cancer. Magnetic Resonance Imaging (MRI uses the protons in water and fat to create the image of breast cancer. But recent studies says neoplastic breast lesions contains elevated choline concentration (tCho and altered mean apparent diffusion coefficient (ADC which can be used as good biomarkers to evaluate the cancer stages even follow up the Neoadjuvent Chemotherapy (NACT.Aim & Objectives:1. To evaluate the relation of age, tCho concentration and mean ADC with breast cancer.2. To estimate the correlation between the factors.3. To calculate the main difference between breast cancer patient before and after menopause.Methods/Study Design: This was a cross sectional, observational study done on 14 randomly selected diagnosed stage I breast cancer patients newly registered in surgery department of All India Institute of Medical Sciences, New Delhi, India during 3 months study period. Intentionally 7 of them were selected to be postmenopausal and rest 7 premenopausal. Patients with claustrophobia, serious illness, pacemaker or associated diseases were excluded. Volunteers were selected by lottery method after confirmation of absence of the exclusion criteria in them. All the breast MRS images were taken only after signing the consent form of being a volunteer for the study with breast coil. All the spectroscopic images were analyzed with computer technologies and SPPS software with the help of non-parametric statistical tests.Results/Findings: Mean age of patients were 44.85±6.97 where in premenopausal and postmenopausal women it was 40.14±4.59 and 49.57±5.26 respectively. tCho concentration was high in postmenopausal women (4.85±2.64 mmol/kg vs 3.72±1.64 where unlike to them premenopausal women

  15. Imaging Surveillance of Patients with Breast Cancer after Primary Treatment: Current Recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jung Hyun; Kim, Min Jung; Kim, Eun-Kyung; Moon, Hee Jung [Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul 120-752 (Korea, Republic of)

    2015-11-01

    Women who have been treated for breast cancer are at risk for second breast cancers, such as ipsilateral recurrence or contralateral metachronous breast cancer. As the number of breast cancer survivors increases, interest in patient management and surveillance after treatment has also increased. However, post-treatment surveillance programs for patients with breast cancer have not been firmly established. In this review, we focus on the imaging modalities that have been used in post-treatment surveillance for patients with breast cancer, such as mammography, ultrasonography, magnetic resonance imaging, and positron emission tomography, the effectiveness of each modality for detecting recurrence, and how they can be applied to manage patients.

  16. Role of MRI (magnetic resonance imaging) versus conventional imaging for breast cancer presurgical staging in young women or with dense breast

    OpenAIRE

    Biglia, N.; Bounous, V.E.; Martincich, L.; Panuccio, E.; Liberale, V.; Ottino, L.; Ponzone, R; Sismondi, P.

    2011-01-01

    Abstract Aims The role of magnetic resonance imaging (MRI) in the local staging of breast cancer is currently uncertain. The purpose of this prospective study is to evaluate the accuracy of preoperative MRI compared to conventional imaging in detecting breast cancer and the effect of pre-operative MRI on the surgical treatment in a subgroup of women with dense breasts, young age, invasive lobular cancer (ILC) or multiple lesions. Methods Between Jan...

  17. Magnetic resonance imaging of trilucent TM breast implants

    International Nuclear Information System (INIS)

    AIM: To demonstrate the magnetic resonance imaging (MRI) appearances of intact and ruptured Trilucent TM implants with imaging and surgical correlation. The appearances of the implant transponder artefact are also described MATERIALS AND METHODS: A retrospective review of the MRI findings in 34 patients with bilateral subpectoral Trilucent TM breast implants (Lipomatrix, Inc./Collagen Aesthetics International Inc., Neuchatel, Switzerland) was performed. Patients under implant surveillance and those with suspected implant rupture formed the study group. Imaging findings were correlated with surgical appearances. RESULTS: Surgical correlation was available in 53% of patients. Fifty per cent (18/36) of implants were intact at surgery, 50% (18/36) of implants were ruptured. Of the 18 ruptured implants, 17 were intracapsular ruptures and one an extracapsular rupture. The sensitivity of MRI for detection of intracapsular rupture in Trilucent TM breast implants was 82% specificity 76%, positive predictive value 78%, negative predictive value 81% and accuracy 79% in this study group. No case of implant rupture was obscured by the transponder artefact. Four implants were found to have 'pseudocapsules' at surgery (5·9%), the implants were intact with fluid present between the implant and capsule. Only one pseudocapsule was demonstrated on MRI. CONCLUSION: Magnetic resonance imaging is currently the most accurate technique for diagnosis of implant rupture in Trilucent TM breast implants. Transponder artefact does not appear to interfere with the assessment of implant rupture. Elson, E. M. et al. (2002)

  18. Molecular Imaging of Breast Cancer: Present and future directions

    Directory of Open Access Journals (Sweden)

    David eAlcantara

    2014-12-01

    Full Text Available Medical imaging technologies have undergone explosive growth over the past few decades and now play a central role in clinical oncology. But the truly transformative power of imaging in the clinical management of cancer patients lies ahead. Today, imaging is at a crossroads, with molecularly targeted imaging agents expected to broadly expand the capabilities of conventional anatomical imaging methods. Molecular imaging will allow clinicians to not only see where a tumour is located in the body, but also to visualize the expression and activity of specific molecules (e.g. proteases and protein kinases and biological processes (e.g. apoptosis, angiogenesis, and metastasis that influence tumour behavior and/or response to therapy. Breast cancer, the most common cancer among women and a research area where our group is actively involved, is a very heterogeneous disease with diverse patterns of development and response to treatment. Hence, molecular imaging is expected to have a major impact on this type of cancer, leading to important improvements in diagnosis, individualized treatment, and drug development, as well as our understanding of how breast cancer arises.

  19. The Ongoing Revolution in Breast Imaging Calls for a Similar Revolution in Breast Pathology

    Directory of Open Access Journals (Sweden)

    L. Tabár

    2012-01-01

    Full Text Available Communication between pathologists and radiologists suffers from a lack of common ground: the pathologists examine cells in ultrathin tissue slices having the area of a postage stamp, while the radiologists examine images of an entire organ, but without seeing the cellular details. The current practice of examining breast cancer specimens is analogous to scrutinizing individual pieces of a jigsaw puzzle, without examining all of them and never putting all the pieces into place. The routine use of large section histopathology technique could help to alleviate much of this problem, especially with nonpalpable, screen-detected breast cancers. The study of three-dimensional (3D images of subgross, thick section pathology specimens by both radiologists and pathologists could greatly assist in the communication of findings.

  20. Fast 3-D Tomographic Microwave Imaging for Breast Cancer Detection

    OpenAIRE

    Grzegorczyk, Tomasz M.; Meaney, Paul M.; Kaufman, Peter A.; DiFlorio-Alexander, Roberta M.; Paulsen, Keith D.

    2012-01-01

    Microwave breast imaging (using electromagnetic waves of frequencies around 1 GHz) has mostly remained at the research level for the past decade, gaining little clinical acceptance. The major hurdles limiting patient use are both at the hardware level (challenges in collecting accurate and noncorrupted data) and software level (often plagued by unrealistic reconstruction times in the tens of hours). In this paper we report improvements that address both issues. First, the hardware is able to ...

  1. Integrating new imaging modalities in breast cancer management

    OpenAIRE

    Pouw, B.

    2016-01-01

    This thesis aimed to integrate new imaging modalities in breast cancer management. In Part 1 the focus was to assess the current status of radioactive seed localisation (RSL) in clinical practice. Both patients as well as physicians or surgeons rated the technique superior compared to the conventional techniques. It is our expectation that when legislation is simplified and standard protocols for this procedure are available the adaptation rate of this procedure will further increase since le...

  2. X-ray image of male breast papilla

    International Nuclear Information System (INIS)

    A comparative study of the frequency of detection of breast papillae of men on X-ray units without amplifiers of X-ray imaging and with X-ray TV has shown that papilla imaging is a common feature in the performance of a modern X-ray unit: the papillae were detected in 2 to 28% of the cases, respectively. A total of 100 men aged 30 to 80 were investigated to study the shape and height of the papillae because these factors predetermined papilla imaging. The maximum diameter and height of the papillae did not exceed 10 mm. Papilla imaging on a TV screen or a panoramic chest X-ray was formed in a cylindrical or similar shape with the papilla height of 4 mm and over. The shape and structure of 23 detected papilla images were analyzed. The problems of differential diagnosis were considered. Imaging of breast papillae of men was proposed for including them in the list of the so-called chest ''soft tissues''

  3. A Modified Harris Corner Detection for Breast IR Image

    Directory of Open Access Journals (Sweden)

    Chia-Yen Lee

    2014-01-01

    Full Text Available Harris corner detectors, which depend on strong invariance and a local autocorrelation function, display poor detection performance for infrared (IR images with low contrast and nonobvious edges. In addition, feature points detected by Harris corner detectors are clustered due to the numerous nonlocal maxima. This paper proposes a modified Harris corner detector that includes two unique steps for processing IR images in order to overcome the aforementioned problems. Image contrast enhancement based on a generalized form of histogram equalization (HE combined with adjusting the intensity resolution causes false contours on IR images to acquire obvious edges. Adaptive nonmaximal suppression based on eliminating neighboring pixels avoids the clustered features. Preliminary results show that the proposed method can solve the clustering problem and successfully identify the representative feature points of IR breast images.

  4. Superelliptical Insert Gradient Coil with a Field Modifying Layer for Breast Imaging

    Science.gov (United States)

    Moon, Sung M.; Goodrich, K. Craig; Hadley, J. Rock; Kim, Seong-Eun; Zeng, Gengsheng L.; Morrell, Glen R.; McAlpine, Matthew A.; Chronik, Blaine A.; Parker, Dennis L.

    2010-01-01

    Many Magnetic Resonance Imaging (MRI) applications such as Dynamic Contrast Enhanced MRI (DCE-MRI) of the breast require high spatial and temporal resolution, and can benefit from improved gradient performance, e.g. increased gradient strength, and reduced gradient rise time. The improved gradient performance required to achieve high spatial and temporal resolution for this application may be achieved by using local insert gradients specifically designed for a target anatomy. Current flat gradient systems cannot create an imaging volume large enough to accommodate both breasts, further, their gradient fields are not homogeneous, dropping off rapidly with distance from the gradient coil surface. To attain an imaging volume adequate for bilateral breast MRI, a planar local gradient system design has been modified into a superellipse shape, creating homogeneous gradient volumes (HGVs) that are 182% (Gx), 57% (Gy), and 75% (Gz) wider (left/right direction) than those of the corresponding standard planar gradient. Adding an additional field-modifying (FM) gradient winding results in an additional improvement of the homogeneous gradient field near the gradient coil surface over the already enlarged HGVs of the superelliptical gradients (67%, 89%, and 214% for Gx, Gy, and Gz respectively). A prototype y-gradient insert has been built to demonstrate imaging and implementation characteristics of the superellipse gradient in a 3T MRI system. PMID:20939085

  5. Quantitative breast tissue characterization using grating-based x-ray phase-contrast imaging

    International Nuclear Information System (INIS)

    X-ray phase-contrast imaging has received growing interest in recent years due to its high capability in visualizing soft tissue. Breast imaging became the focus of particular attention as it is considered the most promising candidate for a first clinical application of this contrast modality. In this study, we investigate quantitative breast tissue characterization using grating-based phase-contrast computed tomography (CT) at conventional polychromatic x-ray sources. Different breast specimens have been scanned at a laboratory phase-contrast imaging setup and were correlated to histopathology. Ascertained tumor types include phylloides tumor, fibroadenoma and infiltrating lobular carcinoma. Identified tissue types comprising adipose, fibroglandular and tumor tissue have been analyzed in terms of phase-contrast Hounsfield units and are compared to high-quality, high-resolution data obtained with monochromatic synchrotron radiation, as well as calculated values based on tabulated tissue properties. The results give a good impression of the method’s prospects and limitations for potential tumor detection and the associated demands on such a phase-contrast breast CT system. Furthermore, the evaluated quantitative tissue values serve as a reference for simulations and the design of dedicated phantoms for phase-contrast mammography. (paper)

  6. Quantitative breast tissue characterization using grating-based x-ray phase-contrast imaging

    Science.gov (United States)

    Willner, M.; Herzen, J.; Grandl, S.; Auweter, S.; Mayr, D.; Hipp, A.; Chabior, M.; Sarapata, A.; Achterhold, K.; Zanette, I.; Weitkamp, T.; Sztrókay, A.; Hellerhoff, K.; Reiser, M.; Pfeiffer, F.

    2014-04-01

    X-ray phase-contrast imaging has received growing interest in recent years due to its high capability in visualizing soft tissue. Breast imaging became the focus of particular attention as it is considered the most promising candidate for a first clinical application of this contrast modality. In this study, we investigate quantitative breast tissue characterization using grating-based phase-contrast computed tomography (CT) at conventional polychromatic x-ray sources. Different breast specimens have been scanned at a laboratory phase-contrast imaging setup and were correlated to histopathology. Ascertained tumor types include phylloides tumor, fibroadenoma and infiltrating lobular carcinoma. Identified tissue types comprising adipose, fibroglandular and tumor tissue have been analyzed in terms of phase-contrast Hounsfield units and are compared to high-quality, high-resolution data obtained with monochromatic synchrotron radiation, as well as calculated values based on tabulated tissue properties. The results give a good impression of the method’s prospects and limitations for potential tumor detection and the associated demands on such a phase-contrast breast CT system. Furthermore, the evaluated quantitative tissue values serve as a reference for simulations and the design of dedicated phantoms for phase-contrast mammography.

  7. Online gamma-camera imaging of 103Pd seeds (OGIPS) for permanent breast seed implantation

    International Nuclear Information System (INIS)

    Permanent brachytherapy seed implantation is being investigated as a mode of accelerated partial breast irradiation for early stage breast cancer patients. Currently, the seeds are poorly visualized during the procedure making it difficult to perform a real-time correction of the implantation if required. The objective was to determine if a customized gamma-camera can accurately localize the seeds during implantation. Monte Carlo simulations of a CZT based gamma-camera were used to assess whether images of suitable quality could be derived by detecting the 21 keV photons emitted from 74 MBq 103Pd brachytherapy seeds. A hexagonal parallel hole collimator with a hole length of 38 mm, hole diameter of 1.2 mm and 0.2 mm septa, was modeled. The design of the gamma-camera was evaluated on a realistic model of the breast and three layers of the seed distribution (55 seeds) based on a pre-implantation CT treatment plan. The Monte Carlo simulations showed that the gamma-camera was able to localize the seeds with a maximum error of 2.0 mm, using only two views and 20 s of imaging. A gamma-camera can potentially be used as an intra-procedural image guidance system for quality assurance for permanent breast seed implantation

  8. Imaging of common breast implants and implant-related complications: A pictorial essay

    Directory of Open Access Journals (Sweden)

    Amisha T Shah

    2016-01-01

    Full Text Available The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  9. Multi-modality fusion of CT, 3D ultrasound, and tracked strain images for breast irradiation planning

    Science.gov (United States)

    Foroughi, Pezhman; Csoma, Csaba; Rivaz, Hassan; Fichtinger, Gabor; Zellars, Richard; Hager, Gregory; Boctor, Emad

    2009-02-01

    Breast irradiation significantly reduces the risk of recurrence of cancer. There is growing evidence suggesting that irradiation of only the involved area of the breast, partial breast irradiation (PBI), is as effective as whole breast irradiation. Benefits of PBI include shortened treatment time, and perhaps fewer side effects as less tissue is treated. However, these benefits cannot be realized without precise and accurate localization of the lumpectomy cavity. Several studies have shown that accurate delineation of the cavity in CT scans is very challenging and the delineated volumes differ dramatically over time and among users. In this paper, we propose utilizing 3D ultrasound (3D-US) and tracked strain images as complementary modalities to reduce uncertainties associated with current CT planning workflow. We present the early version of an integrated system that fuses 3D-US and real-time strain images. For the first time, we employ tracking information to reduce the noise in calculation of strain image by choosing the properly compressed frames and to position the strain image within the ultrasound volume. Using this system, we provide the tools to retrieve additional information from 3D-US and strain image alongside the CT scan. We have preliminarily evaluated our proposed system in a step-by-step fashion using a breast phantom and clinical experiments.

  10. An imaging evaluation of the simultaneously integrated boost breast radiotherapy technique

    International Nuclear Information System (INIS)

    To evaluate in-field megavoltage (MV) imaging of simultaneously integrated boost (SIB) breast fields to determine its feasibility in treatment verification for the SIB breast radiotherapy technique, and to assess whether the current-imaging protocol and treatment margins are sufficient. For nine patients undergoing SIB breast radiotherapy, in-field MV images of the SIB fields were acquired on days that regular treatment verification imaging was performed. The in-field images were matched offline according to the scar wire on digitally reconstructed radiographs. The offline image correction results were then applied to a margin recipe formula to calculate safe margins that account for random and systematic uncertainties in the position of the boost volume when an offline correction protocol has been applied. After offline assessment of the acquired images, 96% were within the tolerance set in the current department-imaging protocol. Retrospectively performing the maximum position deviations on the Eclipse™ treatment planning system demonstrated that the clinical target volume (CTV) boost received a minimum dose difference of 0.4% and a maximum dose difference of 1.4% less than planned. Furthermore, applying our results to the Van Herk margin formula to ensure that 90% of patients receive 95% of the prescribed dose, the calculated CTV margins were comparable to the current departmental procedure used. Based on the in-field boost images acquired and the feasible application of these results to the margin formula the current CTV-planning target volume margins used are appropriate for the accurate treatment of the SIB boost volume without additional imaging

  11. An imaging evaluation of the simultaneously integrated boost breast radiotherapy technique

    Energy Technology Data Exchange (ETDEWEB)

    Turley, Jessica; Claridge Mackonis, Elizabeth [Department of Radiation Oncology, Royal Prince Alfred Hospital, Camperdown, New South Wales (Australia)

    2015-09-15

    To evaluate in-field megavoltage (MV) imaging of simultaneously integrated boost (SIB) breast fields to determine its feasibility in treatment verification for the SIB breast radiotherapy technique, and to assess whether the current-imaging protocol and treatment margins are sufficient. For nine patients undergoing SIB breast radiotherapy, in-field MV images of the SIB fields were acquired on days that regular treatment verification imaging was performed. The in-field images were matched offline according to the scar wire on digitally reconstructed radiographs. The offline image correction results were then applied to a margin recipe formula to calculate safe margins that account for random and systematic uncertainties in the position of the boost volume when an offline correction protocol has been applied. After offline assessment of the acquired images, 96% were within the tolerance set in the current department-imaging protocol. Retrospectively performing the maximum position deviations on the Eclipse™ treatment planning system demonstrated that the clinical target volume (CTV) boost received a minimum dose difference of 0.4% and a maximum dose difference of 1.4% less than planned. Furthermore, applying our results to the Van Herk margin formula to ensure that 90% of patients receive 95% of the prescribed dose, the calculated CTV margins were comparable to the current departmental procedure used. Based on the in-field boost images acquired and the feasible application of these results to the margin formula the current CTV-planning target volume margins used are appropriate for the accurate treatment of the SIB boost volume without additional imaging.

  12. Phase-contrast X-ray imaging of breast

    Energy Technology Data Exchange (ETDEWEB)

    Keyrilaeinen, Jani; Tenhunen, Mikko (Dept. of Physics, HUCH Cancer Center, Helsinki Univ. Central Hospital, Helsinki (Finland)), e-mail: jani.keyrilainen@hus.fi; Bravin, Alberto (Bio-medical Beamline ID17, European Synchrotron Radiation Facility, Grenoble (France)); Fernandez, Manuel (High Brilliance Beamline ID2, European Synchrotron Radiation Facility, Grenoble (France)); Virkkunen, Pekka (Dept. of Radiology, HUCH Cancer Center, Helsinki Univ. Central Hospital, Helsinki (Finland)); Suortti, Pekka (Dept. of Physics, Univ. of Helsinki, Helsinki (Finland))

    2010-10-15

    When an X-ray wave traverses an object, its amplitude and phase change, resulting in attenuation, interference, and refraction, and in phase-contrast X-ray imaging (PCI) these are converted to intensity changes. The relative change of the X-ray phase per unit path length is even orders of magnitude larger than that of the X-ray amplitude, so that the image contrast based on variation of the X-ray phase is potentially much stronger than the contrast based on X-ray amplitude (absorption contrast). An important medical application of PCI methods is soft-tissue imaging, where the absorption contrast is inherently weak. It is shown by in vitro examples that signs of malignant human breast tumor are enhanced in PCI images. Owing to the strong contrast, the radiation dose can be greatly reduced, so that a high-resolution phase-contrast X-ray tomography of the breast is possible with about 1 mGy mean glandular dose. Scattered radiation carries essential information on the atomic and molecular structure of the object, and particularly small-angle X-ray scattering can be used to trace cancer. The imaging methods developed at the synchrotron radiation facilities will become available in the clinical environment with the ongoing development of compact radiation sources, which produce intense X-ray beams of sufficient coherence. Several developments that are under way are described here

  13. Phase-contrast X-ray imaging of breast.

    Science.gov (United States)

    Keyriläinen, Jani; Bravin, Alberto; Fernández, Manuel; Tenhunen, Mikko; Virkkunen, Pekka; Suortti, Pekka

    2010-10-01

    When an X-ray wave traverses an object, its amplitude and phase change, resulting in attenuation, interference, and refraction, and in phase-contrast X-ray imaging (PCI) these are converted to intensity changes. The relative change of the X-ray phase per unit path length is even orders of magnitude larger than that of the X-ray amplitude, so that the image contrast based on variation of the X-ray phase is potentially much stronger than the contrast based on X-ray amplitude (absorption contrast). An important medical application of PCI methods is soft-tissue imaging, where the absorption contrast is inherently weak. It is shown by in vitro examples that signs of malignant human breast tumor are enhanced in PCI images. Owing to the strong contrast, the radiation dose can be greatly reduced, so that a high-resolution phase-contrast X-ray tomography of the breast is possible with about 1 mGy mean glandular dose. Scattered radiation carries essential information on the atomic and molecular structure of the object, and particularly small-angle X-ray scattering can be used to trace cancer. The imaging methods developed at the synchrotron radiation facilities will become available in the clinical environment with the ongoing development of compact radiation sources, which produce intense X-ray beams of sufficient coherence. Several developments that are under way are described here. PMID:20799921

  14. Phase-contrast X-ray imaging of breast

    International Nuclear Information System (INIS)

    When an X-ray wave traverses an object, its amplitude and phase change, resulting in attenuation, interference, and refraction, and in phase-contrast X-ray imaging (PCI) these are converted to intensity changes. The relative change of the X-ray phase per unit path length is even orders of magnitude larger than that of the X-ray amplitude, so that the image contrast based on variation of the X-ray phase is potentially much stronger than the contrast based on X-ray amplitude (absorption contrast). An important medical application of PCI methods is soft-tissue imaging, where the absorption contrast is inherently weak. It is shown by in vitro examples that signs of malignant human breast tumor are enhanced in PCI images. Owing to the strong contrast, the radiation dose can be greatly reduced, so that a high-resolution phase-contrast X-ray tomography of the breast is possible with about 1 mGy mean glandular dose. Scattered radiation carries essential information on the atomic and molecular structure of the object, and particularly small-angle X-ray scattering can be used to trace cancer. The imaging methods developed at the synchrotron radiation facilities will become available in the clinical environment with the ongoing development of compact radiation sources, which produce intense X-ray beams of sufficient coherence. Several developments that are under way are described here

  15. Avoiding preoperative breast MRI when conventional imaging is sufficient to stage patients eligible for breast conserving therapy

    International Nuclear Information System (INIS)

    Aim: To determine when preoperative breast MRI will not be more informative than available breast imaging and can be omitted in patients eligible for breast conserving therapy (BCT). Methods: We performed an MRI in 685 consecutive patients with 692 invasive breast tumors and eligible for BCT based on conventional imaging and clinical examination. We explored associations between patient, tumor, and conventional imaging characteristics and similarity with MRI findings. Receiver operating characteristic (ROC) analysis was employed to compute the area under the curve (AUC). Results: MRI and conventional breast imaging were similar in 585 of the 692 tumors (85%). At univariate analysis, age (p < 0.001), negative preoperative lymph node status (p = 0.011), comparable tumor diameter at mammography and at ultrasound (p = 0.001), negative HER2 status (p = 0.044), and absence of invasive lobular cancer (p = 0.005) were significantly associated with this similarity. At multivariate analysis, these factors, except HER2 status, retained significant associations. The AUC was 0.68. Conclusions: It is feasible to identify a subgroup of patients prior to preoperative breast MRI, who will most likely show similar results on conventional imaging as on MRI. These findings enable formulation of a practical consensus guideline to determine in which patients a preoperative breast MRI can be omitted

  16. Avoiding preoperative breast MRI when conventional imaging is sufficient to stage patients eligible for breast conserving therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pengel, Kenneth E., E-mail: k.pengel@nki.nl [Department of Radiology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Loo, Claudette E. [Department of Radiology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Wesseling, Jelle [Department of Pathology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Pijnappel, Ruud M. [Department of Radiology/Image Sciences Institute, University Medical Center Utrecht Heidelberglaan 100, 3584 CX Utrecht (Netherlands); Rutgers, Emiel J.Th. [Department of Surgical Oncology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Gilhuijs, Kenneth G.A. [Department of Radiology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Department of Radiology/Image Sciences Institute, University Medical Center Utrecht Heidelberglaan 100, 3584 CX Utrecht (Netherlands)

    2014-02-15

    Aim: To determine when preoperative breast MRI will not be more informative than available breast imaging and can be omitted in patients eligible for breast conserving therapy (BCT). Methods: We performed an MRI in 685 consecutive patients with 692 invasive breast tumors and eligible for BCT based on conventional imaging and clinical examination. We explored associations between patient, tumor, and conventional imaging characteristics and similarity with MRI findings. Receiver operating characteristic (ROC) analysis was employed to compute the area under the curve (AUC). Results: MRI and conventional breast imaging were similar in 585 of the 692 tumors (85%). At univariate analysis, age (p < 0.001), negative preoperative lymph node status (p = 0.011), comparable tumor diameter at mammography and at ultrasound (p = 0.001), negative HER2 status (p = 0.044), and absence of invasive lobular cancer (p = 0.005) were significantly associated with this similarity. At multivariate analysis, these factors, except HER2 status, retained significant associations. The AUC was 0.68. Conclusions: It is feasible to identify a subgroup of patients prior to preoperative breast MRI, who will most likely show similar results on conventional imaging as on MRI. These findings enable formulation of a practical consensus guideline to determine in which patients a preoperative breast MRI can be omitted.

  17. Molecular markers in breast cancer: new tools in imaging and prognosis

    OpenAIRE

    Vermeulen, J.F.

    2012-01-01

    Breast cancer is the most frequently diagnosed cancer in women. Although breast cancer is mainly diagnosed by mammography, other imaging modalities (e.g. MRI, PET) are increasingly used. The most recent developments in the field of molecular imaging comprise the application of near-infrared fluorescent labeled (NIRF) tracers for detection of breast cancer. Thus far, only a few molecular imaging tracers have been taken to the clinic of which most are suitable for PET. My thesis describes the e...

  18. Identification of breast calcification using magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fatemi-Ardekani, Ali; Boylan, Colm; Noseworthy, Michael D. [Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ontario L8S 4K1 (Canada) and Imaging Research Centre, Brain-Body Institute, St. Joseph' s Healthcare, Hamilton, Ontario L8N 4A6 (Canada); Diagnostic Imaging, St. Joseph' s Healthcare, Hamilton, Ontario L8N 4A6 (Canada) and Department of Radiology, McMaster University, Hamilton, Ontario L8N 3Z5 (Canada); Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ontario L8S 4K1 (Canada); Imaging Research Centre, Brain-Body Institute, St. Joseph' s Healthcare, Hamilton, Ontario L8N 4A6 (Canada); Diagnostic Imaging, St. Joseph' s Healthcare, Hamilton, Ontario L8N 4A6 (Canada); Department of Radiology, McMaster University, Hamilton, Ontario L8N 3Z5 (Canada) and Electrical and Computer Engineering, and School of Biomedical Engineering, McMaster University, Hamilton, Ontario L8S 4K1 (Canada)

    2009-12-15

    MRI phase and magnitude images provide information about local magnetic field variation ({Delta}B{sub 0}), which can consequently be used to understand tissue properties. Often, phase information is discarded. However, corrected phase images are able to produce contrast as a result of magnetic susceptibility differences and local field inhomogeneities due to the presence of diamagnetic and paramagnetic substances. Three-dimensional (3D) susceptibility weighted imaging (SWI) can be used to probe changes in MRI phase evolution and, subsequently, result in an alternate form of contrast between tissues. For example, SWI has been useful in the assessment of negative phase induced {Delta}B{sub 0} modulation due to the presence of paramagnetic substances such as iron. Very little, however, has been done to assess positive phase induced contrast changes resulting from the presence of diamagnetic substances such as precipitated calcium. As ductal carcinoma in situ, which is the precursor of invasive ductal cancer, is often associated with breast microcalcification, the authors proposed using SWI as a possible visualization technique. In this study, breast phantoms containing calcifications (0.4-1.5 mm) were imaged using mammography, computed tomography (CT), and SWI. Corrected phase and magnitude images acquired using SWI allowed identification and correlation of all calcifications seen on CT. As the approach is a 3D technique, it could potentially allow for more accurate localization and biopsy and maybe even reduce the use of gadolinium contrast. Furthermore, the approach may be beneficial to women with dense breast tissue where the ability to detect microcalcification with mammography is reduced.

  19. Development of Ultrasound Tomography for Breast Imaging: Technical Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Duric, N; Littrup, P; Babkin, A; Chambers, D; Azevedo, S; Arkady, K; Pevzner, R; Tokarev, M; Holsapple, E

    2004-09-30

    Ultrasound imaging is widely used in medicine because of its benign characteristics and real-time capabilities. Physics theory suggests that the application of tomographic techniques may allow ultrasound imaging to reach its full potential as a diagnostic tool allowing it to compete with other tomographic modalities such as X-ray CT and MRI. This paper describes the construction and use of a prototype tomographic scanner and reports on the feasibility of implementing tomographic theory in practice and the potential of US tomography in diagnostic imaging. Data were collected with the prototype by scanning two types of phantoms and a cadaveric breast. A specialized suite of algorithms was developed and utilized to construct images of reflectivity and sound speed from the phantom data. The basic results can be summarized as follows: (1) A fast, clinically relevant US tomography scanner can be built using existing technology. (2) The spatial resolution, deduced from images of reflectivity, is 0.4 mm. The demonstrated 10 cm depth-of-field is superior to that of conventional ultrasound and the image contrast is improved through the reduction of speckle noise and overall lowering of the noise floor. (3) Images of acoustic properties such as sound speed suggest that it is possible to measure variations in the sound speed of 5 m/s. An apparent correlation with X-ray attenuation suggests that the sound speed can be used to discriminate between various types of soft tissue. (4) Ultrasound tomography has the potential to improve diagnostic imaging in relation to breast cancer detection.

  20. Development and assessment of a clinically viable system for breast ultrasound computer-aided diagnosis

    Science.gov (United States)

    Gruszauskas, Nicholas Peter

    The chances of surviving a breast cancer diagnosis as well as the effectiveness of any potential treatments increase significantly with early detection of the disease. As such, a considerable amount of research is being conducted to augment the breast cancer detection and diagnosis process. One such area of research involves the investigation and application of sophisticated computer algorithms to assist clinicians in detecting and diagnosing breast cancer on medical images (termed generally as "computer-aided diagnosis" or CAD). This study investigated a previously-developed breast ultrasound CAD system with the intent of translating it into a clinically-viable system. While past studies have demonstrated that breast ultrasound CAD may be a beneficial aid during the diagnosis of breast cancer on ultrasound, there are no investigations concerning its potential clinical translation and there are currently no commercially-available implementations of such systems. This study "bridges the gap" between the laboratory-developed system and the steps necessary for clinical implementation. A novel observer study was conducted that mimicked the clinical use of the breast ultrasound CAD system in order to assess the impact it had on the diagnostic performance of the user. Several robustness studies were also performed: the sonographic features used by the system were evaluated and the databases used for calibration and testing were characterized, the effect of the user's input was assessed by evaluating the performance of the system with variations in lesion identification and image selection, and the performance of the system on different patient populations was investigated by evaluating its performance on a database consisting solely of patients with Asian ethnicity. The analyses performed here indicate that the breast ultrasound CAD system under investigation is robust and demonstrates only minor variability when subjected to "real-world" use. All of these results are

  1. Stacked Sparse Autoencoder (SSAE) for Nuclei Detection on Breast Cancer Histopathology Images.

    Science.gov (United States)

    Xu, Jun; Xiang, Lei; Liu, Qingshan; Gilmore, Hannah; Wu, Jianzhong; Tang, Jinghai; Madabhushi, Anant

    2016-01-01

    Automated nuclear detection is a critical step for a number of computer assisted pathology related image analysis algorithms such as for automated grading of breast cancer tissue specimens. The Nottingham Histologic Score system is highly correlated with the shape and appearance of breast cancer nuclei in histopathological images. However, automated nucleus detection is complicated by 1) the large number of nuclei and the size of high resolution digitized pathology images, and 2) the variability in size, shape, appearance, and texture of the individual nuclei. Recently there has been interest in the application of "Deep Learning" strategies for classification and analysis of big image data. Histopathology, given its size and complexity, represents an excellent use case for application of deep learning strategies. In this paper, a Stacked Sparse Autoencoder (SSAE), an instance of a deep learning strategy, is presented for efficient nuclei detection on high-resolution histopathological images of breast cancer. The SSAE learns high-level features from just pixel intensities alone in order to identify distinguishing features of nuclei. A sliding window operation is applied to each image in order to represent image patches via high-level features obtained via the auto-encoder, which are then subsequently fed to a classifier which categorizes each image patch as nuclear or non-nuclear. Across a cohort of 500 histopathological images (2200 × 2200) and approximately 3500 manually segmented individual nuclei serving as the groundtruth, SSAE was shown to have an improved F-measure 84.49% and an average area under Precision-Recall curve (AveP) 78.83%. The SSAE approach also out-performed nine other state of the art nuclear detection strategies. PMID:26208307

  2. Invasive micropapillary carcinoma of the breast: MR imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Hyo Soon; Jeong, Seo In; Choi, You Ri; Kim, Jin Woong; Lee, Ji Shin; Park, Min Ho [Chonnam National University Medical School, Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of); Kuzmiak, Cherie M. [Department of Radiology, University of North Carolina, Chapel Hill (Korea, Republic of)

    2013-08-15

    To analyze the magnetic resonance (MR) imaging findings of invasive micropapillary carcinoma of the breast. MR images were retrospectively evaluated in 14 patients (age range: 37-67, mean age: 49 years) with pathologically confirmed invasive micropapillary carcinoma of the breast. The enhancement type (mass/non-mass), shape, margin, contrast enhancement, and time-intensity curve pattern on the dynamic study were correlated with the histopathologic features. Associated findings, such as edema, nipple change, skin change and enlarged axillary lymph nodes were also studied. The most common features of the masses were irregular shape (12 of 14 patients, 85.8%) and irregular or spiculated margin (11 of 14 patients, 78.7%). The contrast enhancement was heterogeneous in 11 patients (78.7%), rim enhancement in 2 cases (14.2%), and homogeneous in one patient (7.1%). The predominant kinetic pattern was rapid increase (14 of 14, 100%) in the initial phase and washout (11 of 14, 78.7%) in the delayed phase. Associated non-mass like enhancement was shown in 4 patients, representing ductal carcinoma in situ. MR imaging helped detect additional sites of cancer other than the index lesion in 3 patients (21.4%). Enlarged axillary lymphadenopathy was identified in 7 of the 14 patients (50%). Invasive micropapillary carcinoma appears as a mass with an irregular shape, irregular or spiculated margin and heterogeneous enhancement on MR imaging. Though these findings are not specific and are also observed with other breast malignancies, invasive micropapillary carcinoma frequently showed multiple lesions, accompanying non-mass enhancement and axillary lymph node enlargement.

  3. Imaging findings in phyllodes tumors of the breast

    International Nuclear Information System (INIS)

    Purpose: To study the radiological appearance and pathological features of breast phyllodes tumors (PTs), and to enhance the recognition of the tumor. Materials and methods: Clinical and imaging findings were retrospectively reviewed in 24 women with PTs confirmed by surgical pathology. All of the 24 patients had preoperative MRI and sonography, and 10 had preoperative mammography. Results: The histologic findings were benign, borderline and malignant PTs in 16.7% (4/24), 45.8% (11/24) and 37.5% (9/24) of cases, respectively. The tumor size (p = 0.001), irregular shape on sonographic imaging (p = 0.039), internal non-enhanced septations (p = 0.009), silt-like changes in enhanced images (p = 0.006) and signal changes from T2-weighted to enhanced images on MRI (p = 0.001) correlated significantly with the histologic grade; the BI-RADS category of the MRI could reflect the PT's histologic grade with a correlation coefficient of 0.440 (p = 0.031). If the category BI-RADS ≥4a was considered to be a suspicious malignant lesion, the diagnostic accuracy of mammography, US and MRI would be 70% (7/10), 62.5% (15/24) and 95.8% (23/24), respectively. Conclusion: The tumor size and several US and MRI findings can be used to help preoperatively determine the histologic grade of breast PTs. When a patient presents with a progressively enlarging, painless breast mass, MRI should be recommended first.

  4. Radiofrequency Heat-Enhanced Chemotherapy for Breast Cancer: Towards Interventional Molecular Image-Guided Chemotherapy

    OpenAIRE

    Zhou, Yurong; Han, Guocan; Wang, Yue; Hu, Xi; Li, Zhiming; Chen, Lumin; Bai, Weixian; Luo, Jingfeng; Zhang, Yajing; Sun, Jihong; Yang, Xiaoming

    2014-01-01

    Breast cancer is the most common malignancy in women worldwide. Recent developments in minimally invasive interventional radiology techniques have significantly improved breast cancer treatment. This study aimed to develop a novel technique for the local management of breast cancers using radiofrequency heat (RFH). We performed both in vitro experiments using human breast cancer cells and in vivo validation in xenograft animal models with magnetic resonance imaging (MRI) and pathological corr...

  5. Monte Carlo simulation of novel breast imaging modalities based on coherent x-ray scattering

    International Nuclear Information System (INIS)

    We present upgraded versions of MC-GPU and penEasyImaging, two open-source Monte Carlo codes for the simulation of radiographic projections and CT, that have been extended and validated to account for the effect of molecular interference in the coherent x-ray scatter. The codes were first validation by comparison between simulated and measured energy dispersive x-ray diffraction (EDXRD) spectra. A second validation was by evaluation of the rejection factor of a focused anti-scatter grid. To exemplify the capabilities of the new codes, the modified MC-GPU code was used to examine the possibility of characterizing breast tissue composition and microcalcifications in a volume of interest inside a whole breast phantom using EDXRD and to simulate a coherent scatter computed tomography (CSCT) system based on first generation CT acquisition geometry. It was confirmed that EDXRD and CSCT have the potential to characterize tissue composition inside a whole breast. The GPU-accelerated code was able to simulate, in just a few hours, a complete CSCT acquisition composed of 9758 independent pencil-beam projections. In summary, it has been shown that the presented software can be used for fast and accurate simulation of novel breast imaging modalities relying on scattering measurements and therefore can assist in the characterization and optimization of promising modalities currently under development. (paper)

  6. Automated planning of breast radiotherapy using cone beam CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Amit, Guy [Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario M5G2M9 (Canada); Purdie, Thomas G., E-mail: tom.purdie@rmp.uhn.ca [Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario M5G2M9 (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5S 3E2 (Canada); Techna Institute, University Health Network, University of Toronto, Toronto, Ontario M5G 1P5 (Canada)

    2015-02-15

    Purpose: Develop and clinically validate a methodology for using cone beam computed tomography (CBCT) imaging in an automated treatment planning framework for breast IMRT. Methods: A technique for intensity correction of CBCT images was developed and evaluated. The technique is based on histogram matching of CBCT image sets, using information from “similar” planning CT image sets from a database of paired CBCT and CT image sets (n = 38). Automated treatment plans were generated for a testing subset (n = 15) on the planning CT and the corrected CBCT. The plans generated on the corrected CBCT were compared to the CT-based plans in terms of beam parameters, dosimetric indices, and dose distributions. Results: The corrected CBCT images showed considerable similarity to their corresponding planning CTs (average mutual information 1.0±0.1, average sum of absolute differences 185 ± 38). The automated CBCT-based plans were clinically acceptable, as well as equivalent to the CT-based plans with average gantry angle difference of 0.99°±1.1°, target volume overlap index (Dice) of 0.89±0.04 although with slightly higher maximum target doses (4482±90 vs 4560±84, P < 0.05). Gamma index analysis (3%, 3 mm) showed that the CBCT-based plans had the same dose distribution as plans calculated with the same beams on the registered planning CTs (average gamma index 0.12±0.04, gamma <1 in 99.4%±0.3%). Conclusions: The proposed method demonstrates the potential for a clinically feasible and efficient online adaptive breast IMRT planning method based on CBCT imaging, integrating automation.

  7. Sensitivity of imaging for multifocal-multicentric breast carcinoma

    Directory of Open Access Journals (Sweden)

    Viale Giuseppe

    2008-09-01

    Full Text Available Abstract Background This retrospective study aims to determine: 1 the sensitivity of preoperative mammography (Mx and ultrasound (US, and re-reviewed Mx to detect multifocal multicentric breast carcinoma (MMBC, defined by pathology on surgical specimens, and 2 to analyze the characteristics of both detected and undetected foci on Mx and US. Methods Three experienced breast radiologists re-reviewed, independently, digital mammography of 97 women with MMBC pathologically diagnosed on surgical specimens. The radiologists were informed of all neoplastic foci, and blinded to the original mammograms and US reports. With regards to Mx, they considered the breast density, number of foci, the Mx characteristics of the lesions and their BI-RADS classification. For US, they considered size of the lesions, BI-RADS classification and US pattern and lesion characteristics. According to the histological size, the lesions were classified as: index cancer, 2nd lesion, 3rd lesion, and 4th lesion. Any pathologically identified malignant foci not previously described in the original imaging reports, were defined as undetected or missed lesions. Sensitivity was calculated for Mx, US and re-reviewed Mx for detecting the presence of the index cancer as well as additional satellite lesions. Results Pathological examination revealed 13 multifocal and 84 multicentric cancers with a total of 303 malignant foci (282 invasive and 21 non invasive. Original Mx and US reports had an overall sensitivity of 45.5% and 52.9%, respectively. Mx detected 83/97 index cancers with a sensitivity of 85.6%. The number of lesions undetected by original Mx was 165/303. The Mx pattern of breasts with undetected lesions were: fatty in 3 (1.8%; scattered fibroglandular density in 40 (24.3%, heterogeneously dense in 91 (55.1% and dense in 31 (18.8% cases. In breasts with an almost entirely fatty pattern, Mx sensitivity was 100%, while in fibroglandular or dense pattern it was reduced to 45

  8. Carcinoma in ectopic breast tissue: imaging aspects (mammography, ultrasonography and magnetic resonance imaging)

    International Nuclear Information System (INIS)

    Over the last three years 30,000 mammograms were performed in the Department of Diagnostic Imaging of Universidade Federal de Sao Paulo/Escola Paulista de Medicina. Accessory breast tissue was observed in 0.23% of the individuals. We report a case of a 44-year-old woman presenting a hard nodule adhered to the subcutaneous tissue in right inframammary topography. At ultrasonography, a hypoechogenic solid nodule with irregular contour measuring 1.4 cm was observed. Magnetic resonance imaging showed type II (plateau) dynamic curve. Breast adenocarcinoma was subsequently diagnosed by biopsy. Accessory breast carcinomas generally present with an ill-defined histopathological aspect and early dissemination. Early detection is essential to begin treatment in the initial stages, with better chances of cure. (author)

  9. Animal testing using 3D microwave tomography system for breast cancer detection.

    Science.gov (United States)

    Lee, Jong Moon; Son, Sung Ho; Kim, Hyuk Je; Kim, Bo Ra; Choi, Heyng Do; Jeon, Soon Ik

    2014-01-01

    The three dimensional microwave tomography (3D MT) system of the Electronics and Telecommunications Research Institute (ETRI) comprises an antenna array, transmitting receiving module, switch matrix module and a signal processing component. This system also includes a patient interface bed as well as a 3D reconstruction algorithm. Here, we perform a comparative analysis of image reconstruction results using the assembled system and MRI results, which is used to image the breasts of dogs. Microwave imaging reconstruction results (at 1,500 MHz) obtained using the ETRI 3D MT system are presented. The system provides computationally reliable diagnosis results from the reconstructed MT Image. PMID:25160233

  10. Computer-aided diagnosis of breast DCE-MRI images using bilateral asymmetry of contrast enhancement between two breasts.

    Science.gov (United States)

    Yang, Qian; Li, Lihua; Zhang, Juan; Shao, Guoliang; Zhang, Chengjie; Zheng, Bin

    2014-02-01

    Dynamic contrast material-enhanced magnetic resonance imaging (DCE-MRI) of breasts is an important imaging modality in breast cancer diagnosis with higher sensitivity but relatively lower specificity. The objective of this study is to investigate a new approach to help improve diagnostic performance of DCE-MRI examinations based on the automated detection and analysis of bilateral asymmetry of characteristic kinetic features between the left and right breast. An image dataset involving 130 DCE-MRI examinations was assembled and used in which 80 were biopsy-proved malignant and 50 were benign. A computer-aided diagnosis (CAD) scheme was developed to segment breast areas depicted on each MR image, register images acquired from the sequential MR image scan series, compute average contrast enhancement of all pixels in one breast, and a set of kinetic features related to the difference of contrast enhancement between the left and right breast, and then use a multi-feature based Bayesian belief network to classify between malignant and benign cases. A leave-one-case-out validation method was applied to test CAD performance. The computed area under a receiver operating characteristic (ROC) curve is 0.78 ± 0.04. The positive and negative predictive values are 0.77 and 0.64, respectively. The study indicates that bilateral asymmetry of kinetic features between the left and right breasts is a potentially useful image biomarker to enhance the detection of angiogenesis associated with malignancy. It also demonstrates the feasibility of applying a simple CAD approach to classify between malignant and benign DCE-MRI examinations based on this new image biomarker. PMID:24043592

  11. Breast imaging: a surgeon's prospective

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, Anne M. [Moores UCSD Cancer Center, University of California, San Diego, La Jolla, CA 92093 (United States); Department of Surgery, University of California, San Diego, La Jolla, CA 92093 (United States); Comstock, Christopher [Moores UCSD Cancer Center, University of California, San Diego, La Jolla, CA 92093 (United States); Department of Radiology, University of California, San Diego, La Jolla, CA 92093 (United States); Hoh, Carl K. [Moores UCSD Cancer Center, University of California, San Diego, La Jolla, CA 92093 (United States); Department of Radiology, University of California, San Diego, La Jolla, CA 92093 (United States); Vera, David R. [Moores UCSD Cancer Center, University of California, San Diego, La Jolla, CA 92093 (United States); Department of Radiology, University of California, San Diego, La Jolla, CA 92093 (United States)

    2005-10-01

    Mammography, ultrasound, magnetic resonance imaging, positron emission tomography, gamma camera and intraoperative gamma detection, and computed tomography are employed in the diagnosis and treatment of breast cancer. This paper summarizes the role of each modality from the perspective of the physician responsible for management of the patient's care. An understanding of an imaging modality's current role can provide insights into the design of new applications and diagnostic agents. Moreover, knowledge of the mechanism by which each modality provides clinical information can guide the design of new imaging methods that complement and add certainty to the patient's management. The reader should note the lack of molecular information provided by the current imaging methods. The perspective concludes with a request for an imaging technique that can measure the biologic aggressiveness of a woman's cancer. The surgeon notes that basing the formation of an image on a molecular process would be compatible with current medical practice, which utilizes molecular concepts to base medical decisions. In addition, molecular imaging will enable rapid translation between basic science and medical practice.

  12. Surface scanning through a cylindrical tank of coupling fluid for clinical microwave breast imaging exams

    International Nuclear Information System (INIS)

    Purpose: Microwave tomographic image quality can be improved significantly with prior knowledge of the breast surface geometry. The authors have developed a novel laser scanning system capable of accurately recovering surface renderings of breast-shaped phantoms immersed within a cylindrical tank of coupling fluid which resides completely external to the tank (and the aqueous environment) and overcomes the challenges associated with the optical distortions caused by refraction from the air, tank wall, and liquid bath interfaces. Methods: The scanner utilizes two laser line generators and a small CCD camera mounted concentrically on a rotating gantry about the microwave imaging tank. Various calibration methods were considered for optimizing the accuracy of the scanner in the presence of the optical distortions including traditional ray tracing and image registration approaches. In this paper, the authors describe the construction and operation of the laser scanner, compare the efficacy of several calibration methods—including analytical ray tracing and piecewise linear, polynomial, locally weighted mean, and thin-plate-spline (TPS) image registrations—and report outcomes from preliminary phantom experiments. Results: The results show that errors in calibrating camera angles and position prevented analytical ray tracing from achieving submillimeter accuracy in the surface renderings obtained from our scanner configuration. Conversely, calibration by image registration reliably attained mean surface errors of less than 0.5 mm depending on the geometric complexity of the object scanned. While each of the image registration approaches outperformed the ray tracing strategy, the authors found global polynomial methods produced the best compromise between average surface error and scanner robustness. Conclusions: The laser scanning system provides a fast and accurate method of three dimensional surface capture in the aqueous environment commonly found in microwave

  13. Breast Imaging in the Era of Big Data: Structured Reporting and Data Mining

    Science.gov (United States)

    Margolies, Laurie R.; Pandey, Gaurav; Horowitz, Eliot R.; Mendelson, David S.

    2016-01-01

    OBJECTIVE The purpose of this article is to describe structured reporting and the development of large databases for use in data mining in breast imaging. CONCLUSION The results of millions of breast imaging examinations are reported with structured tools based on the BI-RADS lexicon. Much of these data are stored in accessible media. Robust computing power creates great opportunity for data scientists and breast imagers to collaborate to improve breast cancer detection and optimize screening algorithms. Data mining can create knowledge, but the questions asked and their complexity require extremely powerful and agile databases. New data technologies can facilitate outcomes research and precision medicine. PMID:26587797

  14. The Application of the Edge Sharpening Operator to the Breast Near-Infrared Imaging

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The principles of Gradient operator, Laplacian operator, LOG operator and Sobel operator are discussed. Certain features of breast can be extracted in different degrees and aspects from original images by applying four edge sharpening operators to the breast near-infrared imaging. A great number of cases prove that compared with the other three operators, the improved Sobel operator can effectively extract the structural features of the breast from an original image. It can be concluded that the improved Sobel operator can assist in diagnosing breast diseases.

  15. Image Processing System

    Science.gov (United States)

    1986-01-01

    Mallinckrodt Institute of Radiology (MIR) is using a digital image processing system which employs NASA-developed technology. MIR's computer system is the largest radiology system in the world. It is used in diagnostic imaging. Blood vessels are injected with x-ray dye, and the images which are produced indicate whether arteries are hardened or blocked. A computer program developed by Jet Propulsion Laboratory known as Mini-VICAR/IBIS was supplied to MIR by COSMIC. The program provides the basis for developing the computer imaging routines for data processing, contrast enhancement and picture display.

  16. Role of Diffusion Weighted Magnetic Resonance Imaging in Evaluation of Suspicious Breast Lesions

    OpenAIRE

    Marwa E Abdelrahman *, Aida M Elshibiny *, Marwa I Fahmy *,

    2013-01-01

    Introduction: Diffusion weighted Imaging “DWI” is a specific modality to produce images of tissues weighted with the local microstructural characteristics of water diffusion. DWI can give information as regards cellularity of breast lesions and it can be used for distinguishing between benign and malignant breast lesions, differentiating surgical scar from recurrence and monitoring therapies in locally advanced breast cancerAim of the work: To assess the diagnostic value of diffusion weighted...

  17. The imaging features of MACROLANE{sup TM} in breast augmentation

    Energy Technology Data Exchange (ETDEWEB)

    Pienaar, W.E., E-mail: wilmipienaar@yahoo.com [Guy' s and St Thomas' NHS Foundation Trust, Guy' s Hospital, London (United Kingdom); McWilliams, S. [Guy' s and St Thomas' NHS Foundation Trust, Guy' s Hospital, London (United Kingdom); Wilding, L.J. [West Middlesex University Hospital, Twickenham Road, Isleworth, Middlesex (United Kingdom); Perera, I.T. [East Kent University Hospital, Ethelbert Road, Canterbury, Kent (United Kingdom)

    2011-10-15

    Macrolane{sup TM} is an injectable, biocompatible, soft-tissue filler that has been available in the UK since 2008 and is promoted for use in breast augmentation. There are few data available on the long-term effects of this relatively new product and concerns have been raised about the implications for breast imaging, in particular breast screening. In this context we present a spectrum of imaging appearances and complications encountered to date.

  18. Use of magnetic resonance imaging in detection of breast cancer recurrence: a systematic review.

    LENUS (Irish Health Repository)

    Quinn, Edel Marie

    2012-09-01

    Diagnosis of breast cancer recurrence can be difficult as a result of the presence of scar tissue in the breast. Magnetic resonance imaging (MRI) may be superior to traditional imaging in diagnosis of recurrence because of its ability to differentiate malignancy from scarring. Current guidelines on investigation of suspected breast cancer recurrence recommend MRI when other investigations have equivocal findings. We performed the first systematic review on this topic.

  19. Online image corrections applied to a dedicated breast PET

    International Nuclear Information System (INIS)

    In this work, we present the online implementation of attenuation, scatter and random corrections using the LMEM algorithm for the dedicated breast PET named MAMMI. The attenuation correction is based on image segmentation, the random correction is derived from the rate estimation of single photon events and the scatter correction is determined by the dual energy window method. These three corrections are estimated and implemented in the reconstruction process without almost increasing the reconstruction time. The image quality is evaluated in terms of image uniformity and contrast using the reconstructed images of two custom-designed phantoms. When we apply the three corrections, the measured uniformity in the whole field of view is (10± 1)% compared to (17± 1)% without corrections. The adapted recovery contrast coefficients (normalized to 1) are approximately (0.80± 0.02) in hot areas, improving the value of (0.66± 0.07) obtained without corrections. The reconstruction processing time is also studied, finding an increment of around 7% when the three corrections are simultaneously included. Finally, 25 breast image datasets are also analyzed. The average acquisition time per patient is around 1200 seconds and the reconstruction times with corrections vary from 100 to 400 seconds using (1× 1× 1) mm3 voxel size and from 300 to 1800 seconds using (0.5× 0.5× 0.5) mm3 voxel size. These reconstructions are performed with a virtual pixel size of (1.6× 1.6) mm2 and twelve iterations

  20. Online image corrections applied to a dedicated breast PET

    Science.gov (United States)

    Moliner, L.; González, A. J.; Correcher, C.; Benlloch, J. M.

    2016-03-01

    In this work, we present the online implementation of attenuation, scatter and random corrections using the LMEM algorithm for the dedicated breast PET named MAMMI. The attenuation correction is based on image segmentation, the random correction is derived from the rate estimation of single photon events and the scatter correction is determined by the dual energy window method. These three corrections are estimated and implemented in the reconstruction process without almost increasing the reconstruction time. The image quality is evaluated in terms of image uniformity and contrast using the reconstructed images of two custom-designed phantoms. When we apply the three corrections, the measured uniformity in the whole field of view is (10± 1)% compared to (17± 1)% without corrections. The adapted recovery contrast coefficients (normalized to 1) are approximately (0.80± 0.02) in hot areas, improving the value of (0.66± 0.07) obtained without corrections. The reconstruction processing time is also studied, finding an increment of around 7% when the three corrections are simultaneously included. Finally, 25 breast image datasets are also analyzed. The average acquisition time per patient is around 1200 seconds and the reconstruction times with corrections vary from 100 to 400 seconds using (1× 1× 1) mm3 voxel size and from 300 to 1800 seconds using (0.5× 0.5× 0.5) mm3 voxel size. These reconstructions are performed with a virtual pixel size of (1.6× 1.6) mm2 and twelve iterations.

  1. Magnetic resonance imaging features of papillary breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Sarica, Ozgur, E-mail: sozgur@yahoo.com; Uluc, Fatih, E-mail: drfatihuluc@yahoo.com; Tasmali, Deniz, E-mail: deniztasmali@hotmail.com

    2014-03-15

    Purpose: This study was aimed to assess the role of magnetic resonance imaging (MRI) in the evaluation of the papillary lesions of the breast and their morphological relationship with the mammary ducts. The potential diagnostic contributory role of ductal oriented protocols to conventional dynamic magnetic resonance examination was also explored. Materials and methods: Retrospective data were collected from 46 patients who had been diagnosed with papillary breast lesions and undergone magnetic resonance examination. The presence of dilated ducts and their morphological relation with the lesion were recorded. Lesions were classified as follows: papilloma, papillomatosis and malignant papillary lesion. Statistical difference between groups was studied for each morphological and dynamic lesion characteristic. Results: Dilated ducts and characteristics of intraductal material can be identified by magnetic resonance imaging. Certain MRI findings such as a mass with crescentic peripheral fluid or focal intraductal mass on T2 weighted images may suggest the presence of an intraductal/papillary lesion. In this respect, non-fatsat T2 weighted images appear particularly useful. There was a significant difference between papilloma and papillomatosis with regard to segmental and heterogeneous contrast enhancement (p < 0.05 for both comparisons). In addition, there was a significant difference between papillomas and carcinomas with regard to homogenous, heterogeneous and segmental contrast enhancement (p < 0.05 for all). On the other hand, papillomatosis and carcinoma did not differ significantly in terms of any of the morphological or dynamical MR criteria compared. Conclusion: Papillary lesions can be detected by MRI. Despite some overlaps in MRI findings between carcinoma, papilloma and papillomatosis, MRI may help differentiate these lesions. Major benefit of retroareolar imaging appears to arise from its ability to demonstrate ductal relation and extension of contrast

  2. Application of signal detection theory to assess optoacoustic imaging systems

    Science.gov (United States)

    Lou, Yang; Oraevsky, Alexander; Anastasio, Mark A.

    2016-03-01

    The hybrid nature of optoacoustic tomography (OAT) brings together the advantages of both optical imaging and ultrasound imaging, making it a promising tool for breast cancer imaging. It is advocated in the modern imaging science literature to utilize objective, or task-based, measures of system performance to guide the optimization of hardware design and image reconstruction algorithms. In this work, we investigate this approach to assess the performance of OAT breast imaging systems. In particular, we apply principles from signal detection theory to compute the detectability of a simulated tumor at different depths within a breast, for two different system designs. The signal-to-noise ratio of the test statistic computed by a numerical observer is employed as the task-specific summary measure of system performance. A numerical breast model is employed that contains both slowly varying background and vessel structures as the background model, and superimpose a deterministic signal to emulate a tumor. This study demonstrates how signal detection performance of a numerical observer will vary as a function of signal depth and imaging system characteristics. The described methodology can be employed readily to systematically optimize other OAT imaging systems for tumor detection tasks.

  3. Preliminary clinical observation of 99mTc-MIBI breast tumor imaging

    International Nuclear Information System (INIS)

    An effective, noninvasive diagnostic method of breast cancer is investigated. 99mTc-MIBI breast tumor imaging was performed in 78 patients with palpable breast mass. All was pathologically proved after operation. Of 78 patients, 42 were breast carcinoma, among them 35 were detected using 99MTc-MIBI scintigraphy. The smallest detectable mass was a infiltrating ductal carcinoma measuring 1.5 cm x 1.5 cm x 1.2 cm. Of 36 patients with benign lesions, 30 with negative result, among the 6 positive one, 5 were big adenoma, 1 was plasma cell mastitis. The sensitivity and specificity of 99mTc-MIBI imaging in detecting breast cancer wa 83.3% either. 99mTc-MIBI scintigraphy can be used as an accessory method in detecting breast cancer. But it was useless for differentiation between breast cancer and big adenoma

  4. Scintimammography: The new role of Technetium-99 m Sestamibi imaging for the diagnosis of breast carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Khalkhali, I.; Diggles, L. E.; Cutrone, J. A.; Mishkin, F. S. [Los Angeles Medical Center, Torrance (United States). Dept. of Radiology; Iraniha, S. [Los Angeles Medical Center, Torrance (United States). Surgery

    1997-09-01

    Technetium-99-Sestamibi scintimammography has emerged as a new procedure for the imaging of breast tumors, Currently, a large clinical experience has been developed and the results published. At the present time, the major drawback of this procedure appears to be its low sensitivity for the detection of breast carcinomas smaller than 1 cm in diameter. There are other biologic and technical issues that remain to be overcome to optimally image the breasts. Some of these include: development of a dedicated breast imager using nuclear medicine techniques, development of stereotactic needle localization of the abnormalities that demonstrate focal increase uptake in women with normal mammogram and breast physical examination, manufacturing of a breast compression device so that they can immobilize the breast in place for more adequate imaging, overcoming the issue of unilateral or bilateral diffuse breast uptake that is noted in 7 - 10 percent of the cases and finally determination of optimal dose and imaging factors. This review includes their experience at Harbor-University of California, Los Angeles Medical Center with the use of this agent for breast imaging since 1992.

  5. Scintimammography: The new role of Technetium-99 m Sestamibi imaging for the diagnosis of breast carcinoma

    International Nuclear Information System (INIS)

    Technetium-99-Sestamibi scintimammography has emerged as a new procedure for the imaging of breast tumors, Currently, a large clinical experience has been developed and the results published. At the present time, the major drawback of this procedure appears to be its low sensitivity for the detection of breast carcinomas smaller than 1 cm in diameter. There are other biologic and technical issues that remain to be overcome to optimally image the breasts. Some of these include: development of a dedicated breast imager using nuclear medicine techniques, development of stereotactic needle localization of the abnormalities that demonstrate focal increase uptake in women with normal mammogram and breast physical examination, manufacturing of a breast compression device so that they can immobilize the breast in place for more adequate imaging, overcoming the issue of unilateral or bilateral diffuse breast uptake that is noted in 7 - 10 percent of the cases and finally determination of optimal dose and imaging factors. This review includes their experience at Harbor-University of California, Los Angeles Medical Center with the use of this agent for breast imaging since 1992

  6. Molecular markers in breast cancer: new tools in imaging and prognosis

    NARCIS (Netherlands)

    Vermeulen, J.F.

    2012-01-01

    Breast cancer is the most frequently diagnosed cancer in women. Although breast cancer is mainly diagnosed by mammography, other imaging modalities (e.g. MRI, PET) are increasingly used. The most recent developments in the field of molecular imaging comprise the application of near-infrared fluoresc

  7. Reconstructing 3-D skin surface motion for the DIET breast cancer screening system.

    Science.gov (United States)

    Botterill, Tom; Lotz, Thomas; Kashif, Amer; Chase, J Geoffrey

    2014-05-01

    Digital image-based elasto-tomography (DIET) is a prototype system for breast cancer screening. A breast is imaged while being vibrated, and the observed surface motion is used to infer the internal stiffness of the breast, hence identifying tumors. This paper describes a computer vision system for accurately measuring 3-D surface motion. A model-based segmentation is used to identify the profile of the breast in each image, and the 3-D surface is reconstructed by fitting a model to the profiles. The surface motion is measured using a modern optical flow implementation customized to the application, then trajectories of points on the 3-D surface are given by fusing the optical flow with the reconstructed surfaces. On data from human trials, the system is shown to exceed the performance of an earlier marker-based system at tracking skin surface motion. We demonstrate that the system can detect a 10 mm tumor in a silicone phantom breast. PMID:24770915

  8. Medical imaging systems

    Energy Technology Data Exchange (ETDEWEB)

    Frangioni, John V. (Wayland, MA)

    2012-07-24

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remains in a subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may also employ dyes or other fluorescent substances associated with antibodies, antibody fragments, or ligands that accumulate within a region of diagnostic significance. In one embodiment, the system provides an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide that is used to capture images. In another embodiment, the system is configured for use in open surgical procedures by providing an operating area that is closed to ambient light. More broadly, the systems described herein may be used in imaging applications where a visible light image may be usefully supplemented by an image formed from fluorescent emissions from a fluorescent substance that marks areas of functional interest.

  9. Mass spectrometry images acylcarnitines, phosphatidylcholines, and sphingomyelin in MDA-MB-231 breast tumor models

    NARCIS (Netherlands)

    Chughtai, K; Jiang, L.; Greenwood, T.R.; Glunde, K.; Heeren, R.M.A.

    2013-01-01

    The lipid compositions of different breast tumor microenvironments are largely unknown due to limitations in lipid imaging techniques. Imaging lipid distributions would enhance our understanding of processes occurring inside growing tumors, such as cancer cell proliferation, invasion, and metastasis

  10. Breast cancer targeting novel microRNA-nanoparticles for imaging

    Science.gov (United States)

    Natarajan, Arutselvan; Venugopal, Senthil K.; DeNardo, Sally J.; Zern, Mark A.

    2009-02-01

    MicroRNAs (miRNAs) are one of the most prevalent small (~22 nucleotide) regulatory RNA classes in animals. These miRNAs constitute nearly one percent of genes in the human genome, making miRNA genes one of the more abundant types of regulatory molecules. MiRNAs have been shown to play important roles in cell development, apoptosis, and other fundamental biological processes. MiRNAs exert their influence through complementary base-pairing with specific target mRNAs, leading to degradation or translational repression of the targeted mRNA. We have identified and tested a novel microRNA (miR-491) and demonstrated increased apoptosis in hepatocellular carcinoma cells (HepG2) and in human breast cancer cells (HBT3477) in vitro. We prepared a novel cancer targeting assembly of gold nanoparticles (GNP) with Quantum dots, miR-491, and MAb-ChL6 coupled through streptavidin/biotin for effective transfection, and to induce apoptosis in specific cancer cells for imaging and targeted therapy. The targeting and apoptosis inducing ability was tested by confocal and electron microscopy. The MAb-GNP-miR491-Qdot construct effectively transfected into the HBT3477 cells and induced apoptosis the confirmation of these results would suggest a new class of molecules for the imaging and therapy of breast cancer.

  11. DIEP Flap Breast Reconstruction Using 3-dimensional Surface Imaging and a Printed Mold

    Directory of Open Access Journals (Sweden)

    Koichi Tomita, MD, PhD

    2015-03-01

    Full Text Available Summary: Recent advances in 3-dimensional (3D surface imaging technologies allow for digital quantification of complex breast tissue. We performed 11 unilateral breast reconstructions with deep inferior epigastric artery perforator (DIEP flaps (5 immediate, 6 delayed using 3D surface imaging for easier surgery planning and 3D-printed molds for shaping the breast neoparenchyma. A single- or double-pedicle flap was preoperatively planned according to the estimated tissue volume required and estimated total flap volume. The DIEP flap was then intraoperatively shaped with a 3D-printed mold that was based on a horizontally inverted shape of the contralateral breast. Cosmetic outcomes were assessed as satisfactory, as confirmed by the postoperative 3D measurements of bilateral breasts. We believe that DIEP flap reconstruction assisted with 3D surface imaging and a 3D-printed mold is a simple and quick method for rebuilding a symmetric breast.

  12. DIEP Flap Breast Reconstruction Using 3-dimensional Surface Imaging and a Printed Mold.

    Science.gov (United States)

    Tomita, Koichi; Yano, Kenji; Hata, Yuki; Nishibayashi, Akimitsu; Hosokawa, Ko

    2015-03-01

    Recent advances in 3-dimensional (3D) surface imaging technologies allow for digital quantification of complex breast tissue. We performed 11 unilateral breast reconstructions with deep inferior epigastric artery perforator (DIEP) flaps (5 immediate, 6 delayed) using 3D surface imaging for easier surgery planning and 3D-printed molds for shaping the breast neoparenchyma. A single- or double-pedicle flap was preoperatively planned according to the estimated tissue volume required and estimated total flap volume. The DIEP flap was then intraoperatively shaped with a 3D-printed mold that was based on a horizontally inverted shape of the contralateral breast. Cosmetic outcomes were assessed as satisfactory, as confirmed by the postoperative 3D measurements of bilateral breasts. We believe that DIEP flap reconstruction assisted with 3D surface imaging and a 3D-printed mold is a simple and quick method for rebuilding a symmetric breast. PMID:25878927

  13. Surface impedance based microwave imaging method for breast cancer screening: contrast-enhanced scenario

    Science.gov (United States)

    Güren, Onan; Çayören, Mehmet; Tükenmez Ergene, Lale; Akduman, Ibrahim

    2014-10-01

    A new microwave imaging method that uses microwave contrast agents is presented for the detection and localization of breast tumours. The method is based on the reconstruction of breast surface impedance through a measured scattered field. The surface impedance modelling allows for representing the electrical properties of the breasts in terms of impedance boundary conditions, which enable us to map the inner structure of the breasts into surface impedance functions. Later a simple quantitative method is proposed to screen breasts against malignant tumours where the detection procedure is based on weighted cross correlations among impedance functions. Numerical results demonstrate that the method is capable of detecting small malignancies and provides reasonable localization.

  14. Metabolic Imaging of Breast Cancer and the Normal Brain

    DEFF Research Database (Denmark)

    Asghar Butt, Sadia

    Cellular metabolism is a set of biochemical reactions that happen in living organisms to maintain life. Enzymes act as catalysts and allow these reactions to proceed quickly and efficiently in order to maintain the cellular function and reproduction. Metabolic Magnetic Resonance Spectroscopy (MRS...... incredible number of exciting possibilities for medical application, including early detection of disease. Such early detection allows for personalized treatment, which may increase the chances for a successful outcome. This PhD thesis is based on experimental studies on the cellular metabolism using MRS in...... two biological systems - breast cancer and normal brain. Breast cancer metabolism was longitudinally monitored in a mouse model using MRS of hyperpolirized pyruvate. The results demonstrated that we could monitor the changes in metabolism with increasing disease severity. The normal cerebral...

  15. Automatic tissue segmentation of breast biopsies imaged by QPI

    Science.gov (United States)

    Majeed, Hassaan; Nguyen, Tan; Kandel, Mikhail; Marcias, Virgilia; Do, Minh; Tangella, Krishnarao; Balla, Andre; Popescu, Gabriel

    2016-03-01

    The current tissue evaluation method for breast cancer would greatly benefit from higher throughput and less inter-observer variation. Since quantitative phase imaging (QPI) measures physical parameters of tissue, it can be used to find quantitative markers, eliminating observer subjectivity. Furthermore, since the pixel values in QPI remain the same regardless of the instrument used, classifiers can be built to segment various tissue components without need for color calibration. In this work we use a texton-based approach to segment QPI images of breast tissue into various tissue components (epithelium, stroma or lumen). A tissue microarray comprising of 900 unstained cores from 400 different patients was imaged using Spatial Light Interference Microscopy. The training data were generated by manually segmenting the images for 36 cores and labelling each pixel (epithelium, stroma or lumen.). For each pixel in the data, a response vector was generated by the Leung-Malik (LM) filter bank and these responses were clustered using the k-means algorithm to find the centers (called textons). A random forest classifier was then trained to find the relationship between a pixel's label and the histogram of these textons in that pixel's neighborhood. The segmentation was carried out on the validation set by calculating the texton histogram in a pixel's neighborhood and generating a label based on the model learnt during training. Segmentation of the tissue into various components is an important step toward efficiently computing parameters that are markers of disease. Automated segmentation, followed by diagnosis, can improve the accuracy and speed of analysis leading to better health outcomes.

  16. An Anatomically Oriented Breast Coordinate System for Mammogram Analysis

    DEFF Research Database (Denmark)

    Brandt, Sami; Karemore, Gopal Raghunath; Karssemeijer, Nico;

    2011-01-01

    were taken prior to when the breast cancer became visible to a radiologist. The coordinate system provides both the relative position and orientation information on the breast region from which the features are derived. In addition, the coordinate system can be used in temporal studies to pin...

  17. Large-scale computations on histology images reveal grade-differentiating parameters for breast cancer

    International Nuclear Information System (INIS)

    Tumor classification is inexact and largely dependent on the qualitative pathological examination of the images of the tumor tissue slides. In this study, our aim was to develop an automated computational method to classify Hematoxylin and Eosin (H&E) stained tissue sections based on cancer tissue texture features. Image processing of histology slide images was used to detect and identify adipose tissue, extracellular matrix, morphologically distinct cell nuclei types, and the tubular architecture. The texture parameters derived from image analysis were then applied to classify images in a supervised classification scheme using histologic grade of a testing set as guidance. The histologic grade assigned by pathologists to invasive breast carcinoma images strongly correlated with both the presence and extent of cell nuclei with dispersed chromatin and the architecture, specifically the extent of presence of tubular cross sections. The two parameters that differentiated tumor grade found in this study were (1) the number density of cell nuclei with dispersed chromatin and (2) the number density of tubular cross sections identified through image processing as white blobs that were surrounded by a continuous string of cell nuclei. Classification based on subdivisions of a whole slide image containing a high concentration of cancer cell nuclei consistently agreed with the grade classification of the entire slide. The automated image analysis and classification presented in this study demonstrate the feasibility of developing clinically relevant classification of histology images based on micro- texture. This method provides pathologists an invaluable quantitative tool for evaluation of the components of the Nottingham system for breast tumor grading and avoid intra-observer variability thus increasing the consistency of the decision-making process

  18. Large-scale computations on histology images reveal grade-differentiating parameters for breast cancer

    Directory of Open Access Journals (Sweden)

    Katsinis Constantine

    2006-10-01

    Full Text Available Abstract Background Tumor classification is inexact and largely dependent on the qualitative pathological examination of the images of the tumor tissue slides. In this study, our aim was to develop an automated computational method to classify Hematoxylin and Eosin (H&E stained tissue sections based on cancer tissue texture features. Methods Image processing of histology slide images was used to detect and identify adipose tissue, extracellular matrix, morphologically distinct cell nuclei types, and the tubular architecture. The texture parameters derived from image analysis were then applied to classify images in a supervised classification scheme using histologic grade of a testing set as guidance. Results The histologic grade assigned by pathologists to invasive breast carcinoma images strongly correlated with both the presence and extent of cell nuclei with dispersed chromatin and the architecture, specifically the extent of presence of tubular cross sections. The two parameters that differentiated tumor grade found in this study were (1 the number density of cell nuclei with dispersed chromatin and (2 the number density of tubular cross sections identified through image processing as white blobs that were surrounded by a continuous string of cell nuclei. Classification based on subdivisions of a whole slide image containing a high concentration of cancer cell nuclei consistently agreed with the grade classification of the entire slide. Conclusion The automated image analysis and classification presented in this study demonstrate the feasibility of developing clinically relevant classification of histology images based on micro- texture. This method provides pathologists an invaluable quantitative tool for evaluation of the components of the Nottingham system for breast tumor grading and avoid intra-observer variability thus increasing the consistency of the decision-making process.

  19. Advancements in Imaging Technology for Detection and Diagnosis of Palpable Breast Masses.

    Science.gov (United States)

    Jaeger, Barbara M; Hong, Andrea S; Letter, Haley; Odell, Matthew C

    2016-06-01

    Breast cancer is the most commonly diagnosed cancer among women worldwide and the most common cause of cancer death in women. The most common presentation of breast cancer is the presence of a palpable mass, whether noted by the patient during breast self-examination or noted during clinical breast examination. There are a variety of imaging modalities now available for the evaluation of a palpable abnormality. A thorough understanding of the indications, risks, and benefits can help the clinician guide the patient through an appropriate, comprehensive imaging work up. PMID:27101239

  20. A minimum spanning forest based classification method for dedicated breast CT images

    Energy Technology Data Exchange (ETDEWEB)

    Pike, Robert [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Sechopoulos, Ioannis [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 and Winship Cancer Institute of Emory University, Atlanta, Georgia 30322 (United States); Fei, Baowei, E-mail: bfei@emory.edu [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgia 30322 (United States); Department of Mathematics and Computer Science, Emory University, Atlanta, Georgia 30322 (United States); Winship Cancer Institute of Emory University, Atlanta, Georgia 30322 (United States)

    2015-11-15

    Purpose: To develop and test an automated algorithm to classify different types of tissue in dedicated breast CT images. Methods: Images of a single breast of five different patients were acquired with a dedicated breast CT clinical prototype. The breast CT images were processed by a multiscale bilateral filter to reduce noise while keeping edge information and were corrected to overcome cupping artifacts. As skin and glandular tissue have similar CT values on breast CT images, morphologic processing is used to identify the skin based on its position information. A support vector machine (SVM) is trained and the resulting model used to create a pixelwise classification map of fat and glandular tissue. By combining the results of the skin mask with the SVM results, the breast tissue is classified as skin, fat, and glandular tissue. This map is then used to identify markers for a minimum spanning forest that is grown to segment the image using spatial and intensity information. To evaluate the authors’ classification method, they use DICE overlap ratios to compare the results of the automated classification to those obtained by manual segmentation on five patient images. Results: Comparison between the automatic and the manual segmentation shows that the minimum spanning forest based classification method was able to successfully classify dedicated breast CT image with average DICE ratios of 96.9%, 89.8%, and 89.5% for fat, glandular, and skin tissue, respectively. Conclusions: A 2D minimum spanning forest based classification method was proposed and evaluated for classifying the fat, skin, and glandular tissue in dedicated breast CT images. The classification method can be used for dense breast tissue quantification, radiation dose assessment, and other applications in breast imaging.

  1. A minimum spanning forest based classification method for dedicated breast CT images

    International Nuclear Information System (INIS)

    Purpose: To develop and test an automated algorithm to classify different types of tissue in dedicated breast CT images. Methods: Images of a single breast of five different patients were acquired with a dedicated breast CT clinical prototype. The breast CT images were processed by a multiscale bilateral filter to reduce noise while keeping edge information and were corrected to overcome cupping artifacts. As skin and glandular tissue have similar CT values on breast CT images, morphologic processing is used to identify the skin based on its position information. A support vector machine (SVM) is trained and the resulting model used to create a pixelwise classification map of fat and glandular tissue. By combining the results of the skin mask with the SVM results, the breast tissue is classified as skin, fat, and glandular tissue. This map is then used to identify markers for a minimum spanning forest that is grown to segment the image using spatial and intensity information. To evaluate the authors’ classification method, they use DICE overlap ratios to compare the results of the automated classification to those obtained by manual segmentation on five patient images. Results: Comparison between the automatic and the manual segmentation shows that the minimum spanning forest based classification method was able to successfully classify dedicated breast CT image with average DICE ratios of 96.9%, 89.8%, and 89.5% for fat, glandular, and skin tissue, respectively. Conclusions: A 2D minimum spanning forest based classification method was proposed and evaluated for classifying the fat, skin, and glandular tissue in dedicated breast CT images. The classification method can be used for dense breast tissue quantification, radiation dose assessment, and other applications in breast imaging

  2. Task-based strategy for optimized contrast enhanced breast imaging: Analysis of six imaging techniques for mammography and tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Ikejimba, Lynda C., E-mail: lci@duke.edu [Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 and Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Kiarashi, Nooshin [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 and Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27705 (United States); Ghate, Sujata V. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Samei, Ehsan [Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27705 (United States); Department of Physics, Duke University, Durham, North Carolina 27705 (United States); Department of Biomedical Engineering, Duke University, Durham, North Carolina 27705 (United States); Lo, Joseph Y. [Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27705 (United States); Department of Biomedical Engineering, Duke University, Durham, North Carolina 27705 (United States)

    2014-06-15

    Purpose: The use of contrast agents in breast imaging has the capability of enhancing nodule detectability and providing physiological information. Accordingly, there has been a growing trend toward using iodine as a contrast medium in digital mammography (DM) and digital breast tomosynthesis (DBT). Widespread use raises concerns about the best way to use iodine in DM and DBT, and thus a comparison is necessary to evaluate typical iodine-enhanced imaging methods. This study used a task-based observer model to determine the optimal imaging approach by analyzing six imaging paradigms in terms of their ability to resolve iodine at a given dose: unsubtracted mammography and tomosynthesis, temporal subtraction mammography and tomosynthesis, and dual energy subtraction mammography and tomosynthesis. Methods: Imaging performance was characterized using a detectability index d{sup ′}, derived from the system task transfer function (TTF), an imaging task, iodine signal difference, and the noise power spectrum (NPS). The task modeled a 10 mm diameter lesion containing iodine concentrations between 2.1 mg/cc and 8.6 mg/cc. TTF was obtained using an edge phantom, and the NPS was measured over several exposure levels, energies, and target-filter combinations. Using a structured CIRS phantom, d{sup ′} was generated as a function of dose and iodine concentration. Results: For all iodine concentrations and dose, temporal subtraction techniques for mammography and tomosynthesis yielded the highest d{sup ′}, while dual energy techniques for both modalities demonstrated the next best performance. Unsubtracted imaging resulted in the lowest d{sup ′} values for both modalities, with unsubtracted mammography performing the worst out of all six paradigms. Conclusions: At any dose, temporal subtraction imaging provides the greatest detectability, with temporally subtracted DBT performing the highest. The authors attribute the successful performance to excellent cancellation of

  3. Task-based strategy for optimized contrast enhanced breast imaging: Analysis of six imaging techniques for mammography and tomosynthesis

    International Nuclear Information System (INIS)

    Purpose: The use of contrast agents in breast imaging has the capability of enhancing nodule detectability and providing physiological information. Accordingly, there has been a growing trend toward using iodine as a contrast medium in digital mammography (DM) and digital breast tomosynthesis (DBT). Widespread use raises concerns about the best way to use iodine in DM and DBT, and thus a comparison is necessary to evaluate typical iodine-enhanced imaging methods. This study used a task-based observer model to determine the optimal imaging approach by analyzing six imaging paradigms in terms of their ability to resolve iodine at a given dose: unsubtracted mammography and tomosynthesis, temporal subtraction mammography and tomosynthesis, and dual energy subtraction mammography and tomosynthesis. Methods: Imaging performance was characterized using a detectability index d′, derived from the system task transfer function (TTF), an imaging task, iodine signal difference, and the noise power spectrum (NPS). The task modeled a 10 mm diameter lesion containing iodine concentrations between 2.1 mg/cc and 8.6 mg/cc. TTF was obtained using an edge phantom, and the NPS was measured over several exposure levels, energies, and target-filter combinations. Using a structured CIRS phantom, d′ was generated as a function of dose and iodine concentration. Results: For all iodine concentrations and dose, temporal subtraction techniques for mammography and tomosynthesis yielded the highest d′, while dual energy techniques for both modalities demonstrated the next best performance. Unsubtracted imaging resulted in the lowest d′ values for both modalities, with unsubtracted mammography performing the worst out of all six paradigms. Conclusions: At any dose, temporal subtraction imaging provides the greatest detectability, with temporally subtracted DBT performing the highest. The authors attribute the successful performance to excellent cancellation of inplane structures and

  4. Mammographic quantitative image analysis and biologic image composition for breast lesion characterization and classification

    International Nuclear Information System (INIS)

    Purpose: To investigate whether biologic image composition of mammographic lesions can improve upon existing mammographic quantitative image analysis (QIA) in estimating the probability of malignancy. Methods: The study population consisted of 45 breast lesions imaged with dual-energy mammography prior to breast biopsy with final diagnosis resulting in 10 invasive ductal carcinomas, 5 ductal carcinomain situ, 11 fibroadenomas, and 19 other benign diagnoses. Analysis was threefold: (1) The raw low-energy mammographic images were analyzed with an established in-house QIA method, “QIA alone,” (2) the three-compartment breast (3CB) composition measure—derived from the dual-energy mammography—of water, lipid, and protein thickness were assessed, “3CB alone”, and (3) information from QIA and 3CB was combined, “QIA + 3CB.” Analysis was initiated from radiologist-indicated lesion centers and was otherwise fully automated. Steps of the QIA and 3CB methods were lesion segmentation, characterization, and subsequent classification for malignancy in leave-one-case-out cross-validation. Performance assessment included box plots, Bland–Altman plots, and Receiver Operating Characteristic (ROC) analysis. Results: The area under the ROC curve (AUC) for distinguishing between benign and malignant lesions (invasive and DCIS) was 0.81 (standard error 0.07) for the “QIA alone” method, 0.72 (0.07) for “3CB alone” method, and 0.86 (0.04) for “QIA+3CB” combined. The difference in AUC was 0.043 between “QIA + 3CB” and “QIA alone” but failed to reach statistical significance (95% confidence interval [–0.17 to + 0.26]). Conclusions: In this pilot study analyzing the new 3CB imaging modality, knowledge of the composition of breast lesions and their periphery appeared additive in combination with existing mammographic QIA methods for the distinction between different benign and malignant lesion types

  5. Mammographic quantitative image analysis and biologic image composition for breast lesion characterization and classification

    Energy Technology Data Exchange (ETDEWEB)

    Drukker, Karen, E-mail: kdrukker@uchicago.edu; Giger, Maryellen L.; Li, Hui [Department of Radiology, University of Chicago, Chicago, Illinois 60637 (United States); Duewer, Fred; Malkov, Serghei; Joe, Bonnie; Kerlikowske, Karla; Shepherd, John A. [Radiology Department, University of California, San Francisco, California 94143 (United States); Flowers, Chris I. [Department of Radiology, University of South Florida, Tampa, Florida 33612 (United States); Drukteinis, Jennifer S. [Department of Radiology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida 33612 (United States)

    2014-03-15

    Purpose: To investigate whether biologic image composition of mammographic lesions can improve upon existing mammographic quantitative image analysis (QIA) in estimating the probability of malignancy. Methods: The study population consisted of 45 breast lesions imaged with dual-energy mammography prior to breast biopsy with final diagnosis resulting in 10 invasive ductal carcinomas, 5 ductal carcinomain situ, 11 fibroadenomas, and 19 other benign diagnoses. Analysis was threefold: (1) The raw low-energy mammographic images were analyzed with an established in-house QIA method, “QIA alone,” (2) the three-compartment breast (3CB) composition measure—derived from the dual-energy mammography—of water, lipid, and protein thickness were assessed, “3CB alone”, and (3) information from QIA and 3CB was combined, “QIA + 3CB.” Analysis was initiated from radiologist-indicated lesion centers and was otherwise fully automated. Steps of the QIA and 3CB methods were lesion segmentation, characterization, and subsequent classification for malignancy in leave-one-case-out cross-validation. Performance assessment included box plots, Bland–Altman plots, and Receiver Operating Characteristic (ROC) analysis. Results: The area under the ROC curve (AUC) for distinguishing between benign and malignant lesions (invasive and DCIS) was 0.81 (standard error 0.07) for the “QIA alone” method, 0.72 (0.07) for “3CB alone” method, and 0.86 (0.04) for “QIA+3CB” combined. The difference in AUC was 0.043 between “QIA + 3CB” and “QIA alone” but failed to reach statistical significance (95% confidence interval [–0.17 to + 0.26]). Conclusions: In this pilot study analyzing the new 3CB imaging modality, knowledge of the composition of breast lesions and their periphery appeared additive in combination with existing mammographic QIA methods for the distinction between different benign and malignant lesion types.

  6. Multidimensional visualization for the immune system state presentation in breast cancer patients

    Science.gov (United States)

    Stakheyeva, M.; Eidenzon, D.; Cherdyntseva, N.; Slonimskaya, E.; Cherdyntsev, E.

    2015-11-01

    The immune system is a complex organization system possessing its hierarchical structure of morphological and functional elements united into an integral unity. Therefore the immune system state should be characterized as an integral unity. The use of the NovoSpark Visualisation approach (Canada) to multidimensional data visualization provides the visual image representing the immune system state as an integral unity. This uniform visual characteristic is formed by values of individual immunological parameters in every person. The curves appropriating the immune system states in breast cancer patients with and without cancer progression (hematogenous metastases) during a 3-year follow-up are located in disjoint areas of the multidimensional data space. The obtained data suggest that the immune system greatly influences the course and outcome of breast cancer. In prospect this approach can be useful for a breast cancer outcome prognosis.

  7. Characterization of human breast disease using phosphorus magnetic resonance spectroscopy and proton magnetic resonance imaging

    International Nuclear Information System (INIS)

    This thesis provides the fundamental characterization and differentiation of breast tissues using in vivo and ex vivo MR techniques in the hope that these techniques and experimental findings will be used on a larger scale and in a predictive manner in order to improve the specificity of diagnosis and treatment of breast cancer. In this dissertation, clinical studies were performed using proton magnetic resonance imaging and phosphorus magnetic resonance spectro-scopy (31P MRS) to characterize and differentiate malignant breast tumors, benign breast tumors and normal breast tissues in vivo. These studies were carried out following the methodical characterization of chemical extracts of malignant breast tumor, benign breast tumor and normal breast parenchymal surgical tissue specimens using high resolution 31P MRS. Alterations in breast tissue metabolism, as a result of pathological processes, were postulated to be responsible for measurable differences between malignant breast tumors, benign breast tumors and normal breast tissues using magnetic resonance techniques. (author). 365 refs.; 37 figs.; 25 tabs

  8. Correlations between diffusion-weighted imaging and breast cancer biomarkers

    Energy Technology Data Exchange (ETDEWEB)

    Martincich, Laura; Deantoni, Veronica; Bertotto, Ilaria; Liotti, Michele; Regge, Daniele [Unit of Radiology, Institute for Cancer Research and Treatment (IRCC), Candiolo, Turin (Italy); Redana, Stefania; Rossi, Valentina; Aglietta, Massimo; Montemurro, Filippo [Institute for Cancer Research and Treatment (IRCC), Division of Medical Oncology, Candiolo, Turin (Italy); Kubatzki, Franziska; Ponzone, Riccardo [Institute for Cancer Research and Treatment (IRCC), Division of Gynecological Oncology, Candiolo, Turin (Italy); Sarotto, Ivana [Unit of Pathology, Institute for Cancer Research and Treatment (IRCC), Candiolo, Turin (Italy)

    2012-07-15

    We evaluated whether the apparent diffusion coefficient (ADC) provided by diffusion-weighted imaging (DWI) varies according to biological features in breast cancer. DWI was performed in 190 patients undergoing dynamic contrast-enhanced magnetic resonance imaging (MRI) for local staging. For each of the 192 index cancers we studied the correlation between ADC and classical histopathological and immunohistochemical breast tumour features (size, histological type, grade, oestrogen receptor [ER] and Ki-67 expression, HER2 status). ADC was compared with immunohistochemical surrogates of the intrinsic subtypes (Luminal A; Luminal B; HER2-enriched; triple-negative). Correlations were analysed using the Mann-Whitney U and Kruskal-Wallis H tests. A weak, statistically significant correlation was observed between ADC values and the percentage of ER-positive cells (-0.168, P = 0.020). Median ADC values were significantly higher in ER-negative than in ER-positive tumours (1.110 vs 1.050 x 10{sup -3} mm{sup 2}/s, P = 0.015). HER2-enriched tumours had the highest median ADC value (1.190 x 10{sup -3} mm{sup 2}/s, range 0.950-2.090). Multiple comparisons showed that this value was significantly higher than that of Luminal A (1.025 x 10{sup -3} mm{sup 2}/s [0.700-1.340], P = 0.004) and Luminal B/HER2-negative (1.060 x 10{sup -3} mm{sup 2}/s [0.470-2.420], P = 0.008) tumours. A trend towards statistical significance (P = 0.018) was seen with Luminal B/HER2-positive tumours. ADC values vary significantly according to biological tumour features, suggesting that cancer heterogeneity influences imaging parameters. (orig.)

  9. Radiation imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Bobbitt, III, John T.; Immel, David M.; Folsom, Matthew D.; Plummer, Jean R.; Serrato, Michael G.

    2016-06-28

    A radiation imaging system includes a casing and a camera disposed inside the casing. A first field of view through the casing exposes the camera to light from outside of the casing. An image plate is disposed inside the casing, and a second field of view through the casing to the image plate exposes the image plate to high-energy particles produced by a radioisotope outside of the casing. An optical reflector that is substantially transparent to the high-energy particles produced by the radioisotope is disposed with respect to the camera and the image plate to reflect light to the camera and to allow the high-energy particles produced by the radioisotope to pass through the optical reflector to the image plate.

  10. Radiation imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Immel, David M.; Bobbit, III, John T.; Plummer, Jean R.; Folsom, Matthew D.; Serrato, Michael G.

    2016-03-22

    A radiation imaging system includes a casing and a camera disposed inside the casing. A first field of view through the casing exposes the camera to light from outside of the casing. An image plate is disposed inside the casing, and a second field of view through the casing to the image plate exposes the image plate to high-energy particles produced by a radioisotope outside of the casing. An optical reflector that is substantially transparent to the high-energy particles produced by the radioisotope is disposed with respect to the camera and the image plate to reflect light to the camera and to allow the high-energy particles produced by the radioisotope to pass through the optical reflector to the image plate.

  11. Remote positioning optical breast magnetic resonance coil for slice-selection during image-guided near-infrared spectroscopy of breast cancer

    OpenAIRE

    Mastanduno, Michael A.; Jiang, Shudong; DiFlorio-Alexander, Roberta; Pogue, Brian W.; Paulsen, Keith D.

    2011-01-01

    The design and testing of a pneumatic optical positioning interface produced with the goal of improving fiber positioning in magnetic resonance (MR)-guided diffuse spectral imaging of breast cancer is presented. The system was created for vertical positioning of optical fibers inside the MR bore during a patient exam to target suspicious lesions with MR scans for reference and collect multiple planes of optical data. The interface includes new fiber plates for mechanical and optical coupling ...

  12. Satellite Imaging System

    Directory of Open Access Journals (Sweden)

    AA Somaie

    2013-06-01

    Full Text Available The aim of this paper is to present the essential elements of the electro-optical imaging system EOIS for space applications and how these elements can affect its function. After designing a spacecraft for low orbiting missions during day time, the design of an electro-imaging system becomes an important part in the satellite because the satellite will be able to take images of the regions of interest. An example of an electro-optical satellite imaging system will be presented through this paper where some restrictions have to be considered during the design process. Based on the optics principals and ray tracing techniques the dimensions of lenses and CCD (Charge Coupled Device detector are changed matching the physical satellite requirements. However, many experiments were done in the physics lab to prove that the resizing of the electro optical elements of the imaging system does not affect the imaging mission configuration. The procedures used to measure the field of view and ground resolution will be discussed through this work. Examples of satellite images will be illustrated to show the ground resolution effects.

  13. The Role of MR Imaging for the Surgical Treatment Planning of Breast Cancer: Comparison with US and the Whole-Excised Breast Histopathologic Correlation

    International Nuclear Information System (INIS)

    We wanted to evaluate the effectiveness of breast magnetic resonance (MR) imaging as a preoperative evaluation modality, as compared with ultrasonography (US) imaging, and we wanted to determine the correlation of MRI and US with using the whole-excised breast histopathology as the standard reference. (Check this and adjust it as needed.) From October 2004 to March 2008, among the 245 patients with breast cancer, 82 patients underwent modified radical mastectomy (MRM). Seven patients were excluded due to receiving neoadjuvant chemotherapy before MRI (n=4) or mammotome excision (n=2) or non-visualization of the mass on US and MR imaging (n=1). The remaining 76 breasts in 75 women (one bilateral) were examined preoperatively with MR imaging and US. On US, 42 cases showed unifocal cancer, 16 showed multifocal cancer and 18 showed multicentric breast cancers. On MRI, 39 cases showed unifocal cancer, 11 showed multifocal cancer and 26 showed multicentric breast cancers. We assessed the US findings to identify the patients who were eligible for breast conservative surgery, and then we evaluated the cancers that were treated with conversion to MRM based on the MR imaging. Histopathologic analysis revealed 45 unifocal, 10 multifocal and 22 multicentric breast cancers. Fifty five of the 76 breasts were indicated for MRM based on the US findings due to multicentric cancers (n=18), unifocal or multifocal lesions near the nipple (n=31), or unifocal or multifocal lesions showing extension towards the nipple (n=6). The remaining 21 breasts were classified as suitable for BCS on US, but 5 patients who desired MRM were excluded. Sixteen breasts were altered to MRM based on the additional findings that were suspicious for malignancy on the MR imaging. Among them, 14 (88%) breasts were adequately converted on the surgical plan to MRM based on the histopathologic verification. The remaining 2 breasts had been overestimated. Breast MRI has a significant effect for the preoperative

  14. Nonlinear dual-spectral image fusion for improving cone-beam-CT-based breast cancer diagnosis

    Science.gov (United States)

    Chen, Zikuan; Ning, Ruola; Conover, David; Willison, Kathleen

    2006-03-01

    Cone-beam breast computed tomography (CB Breast CT) can easily detect micro-calcifications and distinguish fat and glandular tissues from normal breast tissue. However, it may be a challenging task for CB Breast CT to distinguish benign from malignant tumors because of the subtle difference in x-ray attenuation. Due to the use of polyenergetic x-ray source, the x-ray and tissue interaction exhibits energy-dependent attenuation behavior, a phenomenon that, to date, has not been used for breast tissue characterization. We will exploit this spectral nature by equipping our CB Breast CT with dual-spectral imaging. The dual-spectral cone-beam scanning produces two spectral image datasets, from which we propose a nonlinear dual-spectral image fusion scheme to combine them into a single dataset, thereby incorporating the spectral information. In implementation, we will perform dual-spectral image fusion through a bi-variable polynomial that can be established by applying dual-spectral imaging to a reference material (with eight different thicknesses). From the fused dataset, we can reconstruct a volume, called a reference-equivalent volume or a fusion volume. By selecting the benign tissue as a reference material, we obtain a benign-equivalent volume. Likewise, we obtain a malignant-equivalent volume as well. In the pursuit of the discrimination of benign versus malignant tissues in a breast image, we perform intra-image as well as inter-image processing. The intra-image processing is an intensity transformation imposed only to a tomographic breast image itself, while the inter-image processing is exerted on two tomographic images extracted from two volumes. The nonlinear fusion scheme possesses these properties: 1) no noise magnification; 2) no feature dimensionality problem, and 3) drastic enhancement among specific features offered by nonlinear mapping. Its disadvantage lies in the possible misinterpretation resulting from nonlinear mapping.

  15. Image guidance during breast radiotherapy: a phantom dosimetry and radiation-induced second cancer risk study

    Science.gov (United States)

    Quinn, A.; Holloway, L.; Metcalfe, P.

    2013-06-01

    Imaging procedures utilised for patient position verification during breast radiotherapy can add a considerable dose to organs surrounding the target volume on top of therapeutic scatter dose. This study investigated the dose from a breast kilovoltage cone-beam CT (kV-CBCT), a breast megavoltage fan-beam CT (MV-FBCT), and a TomoDirectTM breast treatment. Thermoluminescent dosimeters placed within a female anthropomorphic phantom were utilised to measure the dose to various organs and tissues. The contralateral breast, lungs and heart received 0.40 cGy, 0.45 cGy and 0.40 cGy from the kV-CBCT and 1.74 cGy, 1.39 cGy and 1.73 cGy from the MV-FBCT. In comparison to treatment alone, daily imaging would increase the contralateral breast, contralateral lung and heart dose by a relative 12%, 24% and 13% for the kV-CBCT, and 52%, 101% and 58% for the MV-FBCT. The impact of the imaging dose relative to the treatment dose was assessed with linear and linear-quadratic radiation-induced secondary cancer risk models for the contralateral breast. The additional imaging dose and risk estimates presented in this study should be taken into account when considering an image modality and frequency for patient position verification protocols in breast radiotherapy.

  16. Detection Efficiency of Microcalcification using Computer Aided Diagnosis in the Breast Ultrasonography Images

    International Nuclear Information System (INIS)

    Digital Mammography makes it possible to reproduce the entire breast image. And it is used to detect microcalcification and mass which are the most important point of view of nonpalpable early breast cancer, so it has been used as the primary screening test of breast disease. It is reported that microcalcification of breast lesion is important in diagnosis of early breast cancer. In this study, six types of texture features algorithms are used to detect microcalcification on breast US images and the study has analyzed recognition rate of lesion between normal US images and other US images which microcalification is seen. As a result of the experiment, Computer aided diagnosis recognition rate that distinguishes mammography and breast US disease was considerably high 70-98%. The average contrast and entropy parameters were low in ROC analysis, but sensitivity and specificity of four types parameters were over 90%. Therefore it is possible to detect microcalcification on US images. If not only six types of texture features algorithms but also the research of additional parameter algorithm is being continually proceeded and basis of practical use on CAD is being prepared, it can be a important meaning as pre-reading. Also, it is considered very useful things for early diagnosis of breast cancer.

  17. Development of a small gamma cameral using NaI(Tl)-position sensitive photomultiplier tube for breast imaging

    International Nuclear Information System (INIS)

    The conventional gamma camera is not ideal for scintimammography because of its large detector size (∼500 mm in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. The small gamma camera system consists of a NaI (Tl) crystal (60 mm x 60 mm x 6 mm) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, and analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals (X+, X-, Y+, Y-). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated and digitized via triggering signal and used to localize the position of an event by applying the Anger logic. The intrinsic sensitivity of the system was approximately 8,000 counts/sec/μCi. High quality flood and hole mask images were obtained. Breast phantom containing 2∼7 mm diameter spheres was successfully imaged with a parallel hole collimator. The image displayed accurate size and activity distribution over the imaging field of view. We have successfully developed a small gamma camera using NaI(Tl)-PSPMT and nuclear instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammogrpahy by optimally imaging the breast

  18. Comparison of standard mammography with digital mammography and digital infrared thermal imaging for breast cancer screening

    OpenAIRE

    2010-01-01

    Breast cancer is the most common malignancy in women. Screen-film mammography (SFM) has been considered the gold standard for breast cancer screening and detection. Despite its recognized value in detecting and characterizing breast disease, mammography has important limitations and its false-negative rate ranges from 4% to 34%. Given these limitations, development of imaging modalities that would enhance, complement, or replace mammography has been a priority. Digital mammography (FFDM) and ...

  19. Breast imaging reports for malignant lesions: are we maintaining recommended BI-RADS® lexicon standards?

    International Nuclear Information System (INIS)

    The purpose of this study was to evaluate mammography reports for diagnosed breast cancer cases in major government and private centers in Karachi, Pakistan, with respect to concordance with the Breast Imaging Reports And Data System (BI-RADS®) lexicon. A prospective, descriptive, multicenter study was conducted in the radiology sections of the Aga Khan University Hospital, Pakistan Naval Station Shifa Hospital, Advanced Radiology Clinic, Karachi Institute of Radiotherapy and Nuclear Medicine, and Civil Hospital Karachi between May and October 2010 after approval from the ethical review committee of Aga Khan University. Mammograms reported as BI-RADS category 4 and 5 were included in the study. Mammograms reported as BI-RADS category 0, 1, 2 and 3 were excluded. Fifty reports were collected from each center. Data were collected about the clinical indication, breast density, location and description of the lesion, calcification, and comments on axillary lymph nodes. This description was compared with the BI-RADS lexicon. The mean age of the patients was 50 ± 12 years. The clinical indication, breast parenchymal density, lesion location, and presence of calcification were better described by the private centers, while description of lymph node status was better stated by the government centers. This difference was statistically significant, except for lesion description. The description of masses by the two reporting groups was comparable. Mammographic reporting of malignant breast lesions in the private sector is more in line with the BI-RADS lexicon, as compared with government sector hospitals in Karachi, Pakistan. Lymph node documentation was better in government sector reports

  20. Preliminary images from an adaptive imaging system

    NARCIS (Netherlands)

    J.A. Griffiths; M.G. Metaxas; S. Pani; H. Schulerud; C. Esbrand; G.J. Royle; B. Price; T. Rokvic; R. Longo; A. Asimidis; E. Bletsas; D. Cavouras; A. Fant; P. Gasiorek; H. Georgiou; G. Hall; J. Jones; J. Leaver; G. Li; D. Machin; N. Manthos; J. Matheson; M. Noy; J.M. Østby; F. Psomadellis; P.F. van der Stelt; S. Theodoridis; F. Triantis; R. Turchetta; C. Venanzi; R.D. Speller

    2008-01-01

    I-ImaS (Intelligent Imaging Sensors) is a European project aiming to produce real-time adaptive X-ray imaging systems using Monolithic Active Pixel Sensors (MAPS) to create images with maximum diagnostic information within given dose constraints. Initial systems concentrate on mammography and cephal

  1. Tangible imaging systems

    Science.gov (United States)

    Ferwerda, James A.

    2013-03-01

    We are developing tangible imaging systems1-4 that enable natural interaction with virtual objects. Tangible imaging systems are based on consumer mobile devices that incorporate electronic displays, graphics hardware, accelerometers, gyroscopes, and digital cameras, in laptop or tablet-shaped form-factors. Custom software allows the orientation of a device and the position of the observer to be tracked in real-time. Using this information, realistic images of threedimensional objects with complex textures and material properties are rendered to the screen, and tilting or moving in front of the device produces realistic changes in surface lighting and material appearance. Tangible imaging systems thus allow virtual objects to be observed and manipulated as naturally as real ones with the added benefit that object properties can be modified under user control. In this paper we describe four tangible imaging systems we have developed: the tangiBook - our first implementation on a laptop computer; tangiView - a more refined implementation on a tablet device; tangiPaint - a tangible digital painting application; and phantoView - an application that takes the tangible imaging concept into stereoscopic 3D.

  2. Breast magnetic resonance imaging in patients with occult breast carcinoma: evaluation on feasibility and correlation with histopathological findings

    Institute of Scientific and Technical Information of China (English)

    LU Hong; XU Yi-lin; ZHANG Shu-ping; LANG Rong-gang; Chi S.Zee; LIU Pei-fang; FU Li

    2011-01-01

    Background As an uncommon presentation, occult primary breast cancer remains a diagnostic and therapeutic challenge in clinical practice. This study aimed to retrospectively assess the feasibility of breast magnetic resonance imaging (MRI) in patients with malignant axillary lymphadenopathy and unknown primary malignancy, and correlation with histopathological characteristics.Methods A total of 35 women with occult breast carcinoma were evaluated with dynamic contrast-enhanced breast MRI. Whole seriate section was used in all cases. MRI performance was assessed and correlated with histopathological findings.Results Twenty-one of 35 patients were found to have primary breast carcinoma histologically. Twenty of the 21 patients had abnormal MR findings and 1 patient had a normal MRI study. Of the remaining 14 patients, 10 were negative on both MRI and surgery. Four had suspicious enhancement on MRI and no corresponding tumor was found. Lesions with mass enhancement were found in 55% (11/20) and ductual and segmental enhancement in 45%. The average diameter of the primary tumors was 15 mm. Invasive ductal carcinomas were found in 81% (17/21). One of 17 invasive ductual carcinomas was too small to be graded. Fourteen of the remaining 16 were classified as grade II and 2 as grade I. Thirty-two of the 35 patients had received estrogen receptor, progesterone receptor and human epidermal growth factor receptor 2 examinations and the 12 of 32 were triple-negative breast carcinoma.Conclusions Mass lesions with small size and lesions with ductal or segment enhancement are common MRI features in patients with occult breast cancer. The dominant types of primary tumors are invasive ductal carcinoma with moderate histopathological grade. The rate of triple-negative breast carcinoma may be higher in occult breast cancer.

  3. Comparison of the diagnostic performance of digital breast tomosynthesis and magnetic resonance imaging added to digital mammography in women with known breast cancers

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Won Hwa; Chang, Jung Min; Moon, Woo Kyung [Seoul National University Hospital, Department of Radiology, 101 Daehangno, Jongno-gu, Seoul (Korea, Republic of); Moon, Hyeong-Gon [Seoul National University Hospital, Department of Surgery, Seoul (Korea, Republic of); Yi, Ann [Seoul National University Hospital, Department of Radiology, Gangnan Healthcare Center, Seoul (Korea, Republic of); Koo, Hye Ryoung [Hanyang University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Gweon, Hye Mi [Yonsei University College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea, Republic of)

    2016-06-15

    To compare the diagnostic performance of digital breast tomosynthesis (DBT) and magnetic resonance imaging (MRI) added to mammography in women with known breast cancers. Three radiologists independently reviewed image sets of 172 patients with 184 cancers; mammography alone, DBT plus mammography and MRI plus mammography, and scored for cancer probability using the Breast Imaging Reporting and Data System (BI-RADS). Jack-knife alternative free-response receiver-operating characteristic (JAFROC), which allows diagnostic performance estimation using single lesion as a statistical unit in a cancer-only population, was used. Sensitivity and positive predictive value (PPV) were compared using the McNemar and Fisher-exact tests. The JAFROC figures of merit (FOMs) was lower in DBT plus mammography (0.937) than MRI plus mammography (0.978, P = 0.0006) but higher than mammography alone (0.900, P = 0.0013). The sensitivity was lower in DBT plus mammography (88.2 %) than MRI plus mammography (97.8 %) but higher than mammography alone (78.3 %, both P < 0.0001). The PPV was significantly higher in DBT plus mammography (93.3 %) than MRI plus mammography (89.6 %, P = 0.0282). DBT provided lower diagnostic performance than MRI as an adjunctive imaging to mammography. However, DBT had higher diagnostic performance than mammography and higher PPV than MRI. (orig.)

  4. Comparison of the diagnostic performance of digital breast tomosynthesis and magnetic resonance imaging added to digital mammography in women with known breast cancers

    International Nuclear Information System (INIS)

    To compare the diagnostic performance of digital breast tomosynthesis (DBT) and magnetic resonance imaging (MRI) added to mammography in women with known breast cancers. Three radiologists independently reviewed image sets of 172 patients with 184 cancers; mammography alone, DBT plus mammography and MRI plus mammography, and scored for cancer probability using the Breast Imaging Reporting and Data System (BI-RADS). Jack-knife alternative free-response receiver-operating characteristic (JAFROC), which allows diagnostic performance estimation using single lesion as a statistical unit in a cancer-only population, was used. Sensitivity and positive predictive value (PPV) were compared using the McNemar and Fisher-exact tests. The JAFROC figures of merit (FOMs) was lower in DBT plus mammography (0.937) than MRI plus mammography (0.978, P = 0.0006) but higher than mammography alone (0.900, P = 0.0013). The sensitivity was lower in DBT plus mammography (88.2 %) than MRI plus mammography (97.8 %) but higher than mammography alone (78.3 %, both P < 0.0001). The PPV was significantly higher in DBT plus mammography (93.3 %) than MRI plus mammography (89.6 %, P = 0.0282). DBT provided lower diagnostic performance than MRI as an adjunctive imaging to mammography. However, DBT had higher diagnostic performance than mammography and higher PPV than MRI. (orig.)

  5. Speckle noise reduction in breast ultrasound images: SMU (srad median unsharp) approch

    International Nuclear Information System (INIS)

    Image denoising has become a very essential for better information extraction from the image and mainly from so noised ones, such as ultrasound images. In certain cases, for instance in ultrasound images, the noise can restrain information which is valuable for the general practitioner. Consequently medical images are very inconsistent, and it is crucial to operate case to case. This paper presents a novel algorithm SMU (Srad Median Unsharp) for noise suppression in ultrasound breast images in order to realize a computer aided diagnosis (CAD) for breast cancer.

  6. A review of breast tomosynthesis. Part II. Image reconstruction, processing and analysis, and advanced applications.

    Science.gov (United States)

    Sechopoulos, Ioannis

    2013-01-01

    Many important post-acquisition aspects of breast tomosynthesis imaging can impact its clinical performance. Chief among them is the reconstruction algorithm that generates the representation of the three-dimensional breast volume from the acquired projections. But even after reconstruction, additional processes, such as artifact reduction algorithms, computer aided detection and diagnosis, among others, can also impact the performance of breast tomosynthesis in the clinical realm. In this two part paper, a review of breast tomosynthesis research is performed, with an emphasis on its medical physics aspects. In the companion paper, the first part of this review, the research performed relevant to the image acquisition process is examined. This second part will review the research on the post-acquisition aspects, including reconstruction, image processing, and analysis, as well as the advanced applications being investigated for breast tomosynthesis. PMID:23298127

  7. Potential Impact of Preoperative Magnetic Resonance Imaging of the Breast on Patient Selection for Accelerated Partial Breast Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Kuehr, Marietta, E-mail: marietta.kuehr@ukb.uni-bonn.de [Department of Obstetrics and Gynecology and Center of Integrated Oncology, University of Bonn, Bonn (Germany); Wolfgarten, Matthias; Stoelzle, Marco [Department of Obstetrics and Gynecology and Center of Integrated Oncology, University of Bonn, Bonn (Germany); Leutner, Claudia [Department of Radiology, Center of Integrated Oncology, University of Bonn, Bonn (Germany); Hoeller, Tobias [Department of Medical Statistics and Epidemiology, University of Bonn, Bonn (Germany); Schrading, Simone; Kuhl, Christiane; Schild, Hans [Department of Radiology, Center of Integrated Oncology, University of Bonn, Bonn (Germany); Kuhn, Walther; Braun, Michael [Department of Obstetrics and Gynecology and Center of Integrated Oncology, University of Bonn, Bonn (Germany)

    2011-11-15

    Purpose: Accelerated partial breast irradiation (APBI) after breast-conserving therapy is currently under investigation in prospective randomized studies. Multifocality and multicentricity are exclusion criteria for APBI. Preoperative breast magnetic resonance imaging (MRI) can detect ipsilateral and contralateral invasive tumor foci or ductal carcinoma in situ in addition to conventional diagnostic methods (clinical examination, mammography, and ultrasonography). The objective of this retrospective study was to evaluate the impact of preoperative MRI on patient selection for APBI. Methods and Materials: From 2002 to 2007, a total of 579 consecutive, nonselected patients with newly diagnosed early-stage breast cancer received preoperative breast MRI in addition to conventional imaging studies at the Bonn University Breast Cancer Center. In retrospect, 113 patients would have met the criteria for APBI using conventional imaging workup (clinical tumor size {<=}3 cm; negative axillary lymph node status; unifocal disease; no evidence of distant metastases; no invasive lobular carcinoma, ductal and lobular carcinoma in situ, or Paget's disease). We analyzed the amount of additional ipsilateral and contralateral tumor foci detected by MRI. Results: MRI detected additional tumor foci in 8.8% of patients eligible for APBI (11 tumor foci in 10 of 113 patients), either ipsilateral (n = 7, 6.2%) or contralateral (n = 4, 3.5%). In 1 patient, MRI helped detect additional tumor focus both ipsilaterally and contralaterally. Conclusions: Preoperative breast MRI is able to identify additional tumor foci in a clinically relevant number of cases in this highly selected group of patients with low-risk disease and may be useful in selecting patients for APBI.

  8. Cowden Syndrome Presenting as Breast Cancer: Imaging and Clinical Features

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Mirinae [Dept. of Radiology, Graduate School of Medicine, Kyung Hee University, Seoul (Korea, Republic of); Cho, Nariya; Moon, Hyeong Gon [Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); Ahn, Hye Shin [Dept. of Radiology, Chung-Ang University Hospital, Seoul (Korea, Republic of)

    2014-10-15

    Cowden syndrome is an uncommon, autosomal dominant disease which is characterized by multiple hamartomas of the skin, mucous membrane, brain, breast, thyroid, and gastrointestinal tract. The diagnosis of Cowden syndrome implicates an increased risk of developing breast cancer. We report a case of a 22-year-old woman with Cowden syndrome that presented as breast cancer with concomitant bilateral exuberant benign masses in both breasts.

  9. Visualization of suspicious lesions in breast MRI based on intelligent neural systems

    Science.gov (United States)

    Twellmann, Thorsten; Lange, Oliver; Nattkemper, Tim Wilhelm; Meyer-Bäse, Anke

    2006-05-01

    Intelligent medical systems based on supervised and unsupervised artificial neural networks are applied to the automatic visualization and classification of suspicious lesions in breast MRI. These systems represent an important component of future sophisticated computer-aided diagnosis systems and enable the extraction of spatial and temporal features of dynamic MRI data stemming from patients with confirmed lesion diagnosis. By taking into account the heterogenity of the cancerous tissue, these techniques reveal the malignant, benign and normal kinetic signals and and provide a regional subclassification of pathological breast tissue. Intelligent medical systems are expected to have substantial implications in healthcare politics by contributing to the diagnosis of indeterminate breast lesions by non-invasive imaging.

  10. MO-A-BRD-06: In Vivo Cherenkov Video Imaging to Verify Whole Breast Irradiation Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, R; Glaser, A [Dartmouth College, Hanover, NH - New Hampshire (United States); Jarvis, L [Dartmouth-Hitchcock Medical Center, City Of Lebanon, New Hampshire (United States); Gladstone, D [Dartmouth-Hitchcock Medical Center, Hanover, City of Lebanon (Lebanon); Andreozzi, J; Hitchcock, W; Pogue, B [Dartmouth College, Hanover, NH (United States)

    2014-06-15

    Purpose: To show in vivo video imaging of Cherenkov emission (Cherenkoscopy) can be acquired in the clinical treatment room without affecting the normal process of external beam radiation therapy (EBRT). Applications of Cherenkoscopy, such as patient positioning, movement tracking, treatment monitoring and superficial dose estimation, were examined. Methods: In a phase 1 clinical trial, including 12 patients undergoing post-lumpectomy whole breast irradiation, Cherenkov emission was imaged with a time-gated ICCD camera synchronized to the radiation pulses, during 10 fractions of the treatment. Images from different treatment days were compared by calculating the 2-D correlations corresponding to the averaged image. An edge detection algorithm was utilized to highlight biological features, such as the blood vessels. Superficial dose deposited at the sampling depth were derived from the Eclipse treatment planning system (TPS) and compared with the Cherenkov images. Skin reactions were graded weekly according to the Common Toxicity Criteria and digital photographs were obtained for comparison. Results: Real time (fps = 4.8) imaging of Cherenkov emission was feasible and feasibility tests indicated that it could be improved to video rate (fps = 30) with system improvements. Dynamic field changes due to fast MLC motion were imaged in real time. The average 2-D correlation was about 0.99, suggesting the stability of this imaging technique and repeatability of patient positioning was outstanding. Edge enhanced images of blood vessels were observed, and could serve as unique biological markers for patient positioning and movement tracking (breathing). Small discrepancies exists between the Cherenkov images and the superficial dose predicted from the TPS but the former agreed better with actual skin reactions than did the latter. Conclusion: Real time Cherenkoscopy imaging during EBRT is a novel imaging tool that could be utilized for patient positioning, movement tracking

  11. MO-A-BRD-06: In Vivo Cherenkov Video Imaging to Verify Whole Breast Irradiation Treatment

    International Nuclear Information System (INIS)

    Purpose: To show in vivo video imaging of Cherenkov emission (Cherenkoscopy) can be acquired in the clinical treatment room without affecting the normal process of external beam radiation therapy (EBRT). Applications of Cherenkoscopy, such as patient positioning, movement tracking, treatment monitoring and superficial dose estimation, were examined. Methods: In a phase 1 clinical trial, including 12 patients undergoing post-lumpectomy whole breast irradiation, Cherenkov emission was imaged with a time-gated ICCD camera synchronized to the radiation pulses, during 10 fractions of the treatment. Images from different treatment days were compared by calculating the 2-D correlations corresponding to the averaged image. An edge detection algorithm was utilized to highlight biological features, such as the blood vessels. Superficial dose deposited at the sampling depth were derived from the Eclipse treatment planning system (TPS) and compared with the Cherenkov images. Skin reactions were graded weekly according to the Common Toxicity Criteria and digital photographs were obtained for comparison. Results: Real time (fps = 4.8) imaging of Cherenkov emission was feasible and feasibility tests indicated that it could be improved to video rate (fps = 30) with system improvements. Dynamic field changes due to fast MLC motion were imaged in real time. The average 2-D correlation was about 0.99, suggesting the stability of this imaging technique and repeatability of patient positioning was outstanding. Edge enhanced images of blood vessels were observed, and could serve as unique biological markers for patient positioning and movement tracking (breathing). Small discrepancies exists between the Cherenkov images and the superficial dose predicted from the TPS but the former agreed better with actual skin reactions than did the latter. Conclusion: Real time Cherenkoscopy imaging during EBRT is a novel imaging tool that could be utilized for patient positioning, movement tracking

  12. Does Breast Magnetic Resonance Imaging Combined With Conventional Imaging Modalities Decrease the Rates of Surgical Margin Involvement and Reoperation?

    Science.gov (United States)

    Lai, Hung-Wen; Chen, Chih-Jung; Lin, Ying-Jen; Chen, Shu-Ling; Wu, Hwa-Koon; Wu, Yu-Ting; Kuo, Shou-Jen; Chen, Shou-Tung; Chen, Dar-Ren

    2016-01-01

    Abstract The objective of this study was to assess whether preoperative breast magnetic resonance imaging (MRI) combined with conventional breast imaging techniques decreases the rates of margin involvement and reexcision. Data on patients who underwent surgery for primary operable breast cancer were obtained from the Changhua Christian Hospital (CCH) breast cancer database. The rate of surgical margin involvement and the rate of reoperation were compared between patients who underwent conventional breast imaging modalities (Group A: mammography and sonography) and those who received breast MRI in addition to conventional imaging (Group B: mammography, sonography, and MRI). A total of 1468 patients were enrolled in this study. Among the 733 patients in Group A, 377 (51.4%) received breast-conserving surgery (BCS) and 356 (48.6%) received mastectomy. Among the 735 patients in Group B, 348 (47.3%) received BCS and 387 (52.7%) received mastectomy. There were no significant differences in operative method between patients who received conventional imaging alone and those that received MRI and conventional imaging (P = 0.13). The rate of detection of pathological multifocal/multicentric breast cancer was markedly higher in patients who received preoperative MRI than in those who underwent conventional imaging alone (14.3% vs 8.6%, P < 0.01). The overall rate of surgical margin involvement was significantly lower in patients who received MRI (5.0%) than in those who received conventional imaging alone (9.0%) (P < 0.01). However, a significant reduction in rate of surgical margin positivity was only observed in patients who received BCS (Group A, 14.6%; Group B, 6.6%, P < 0.01). The overall BCS reoperation rates were 11.7% in the conventional imaging group and 3.2% in the combined MRI group (P < 0.01). There were no significant differences in rate of residual cancer in specimens obtained during reoperation between the 2 preoperative imaging groups

  13. Evaluation of the possibility to use thick slabs of reconstructed outer breast tomosynthesis slice images

    Science.gov (United States)

    Petersson, Hannie; Dustler, Magnus; Tingberg, Anders; Timberg, Pontus

    2016-03-01

    The large image volumes in breast tomosynthesis (BT) have led to large amounts of data and a heavy workload for breast radiologists. The number of slice images can be decreased by combining adjacent image planes (slabbing) but the decrease in depth resolution can considerably affect the detection of lesions. The aim of this work was to assess if thicker slabbing of the outer slice images (where lesions seldom are present) could be a viable alternative in order to reduce the number of slice images in BT image volumes. The suggested slabbing (an image volume with thick outer slabs and thin slices between) were evaluated in two steps. Firstly, a survey of the depth of 65 cancer lesions within the breast was performed to estimate how many lesions would be affected by outer slabs of different thicknesses. Secondly, a selection of 24 lesions was reconstructed with 2, 6 and 10 mm slab thickness to evaluate how the appearance of lesions located in the thicker slabs would be affected. The results show that few malignant breast lesions are located at a depth less than 10 mm from the surface (especially for breast thicknesses of 50 mm and above). Reconstruction of BT volumes with 6 mm slab thickness yields an image quality that is sufficient for lesion detection for a majority of the investigated cases. Together, this indicates that thicker slabbing of the outer slice images is a promising option in order to reduce the number of slice images in BT image volumes.

  14. Breast ultrasound image segmentation: an optimization approach based on super-pixels and high-level descriptors

    Science.gov (United States)

    Massich, Joan; Lemaître, Guillaume; Martí, Joan; Mériaudeau, Fabrice

    2015-04-01

    Breast cancer is the second most common cancer and the leading cause of cancer death among women. Medical imaging has become an indispensable tool for its diagnosis and follow up. During the last decade, the medical community has promoted to incorporate Ultra-Sound (US) screening as part of the standard routine. The main reason for using US imaging is its capability to differentiate benign from malignant masses, when compared to other imaging techniques. The increasing usage of US imaging encourages the development of Computer Aided Diagnosis (CAD) systems applied to Breast Ultra-Sound (BUS) images. However accurate delineations of the lesions and structures of the breast are essential for CAD systems in order to extract information needed to perform diagnosis. This article proposes a highly modular and flexible framework for segmenting lesions and tissues present in BUS images. The proposal takes advantage of optimization strategies using super-pixels and high-level descriptors, which are analogous to the visual cues used by radiologists. Qualitative and quantitative results are provided stating a performance within the range of the state-of-the-art.

  15. Computerized database management system for breast cancer patients

    OpenAIRE

    Sim, Kok Swee; Chong, Sze Siang; Tso, Chih Ping; Nia, Mohsen Esmaeili; Chong, Aun Kee; Abbas, Siti Fathimah

    2014-01-01

    Data analysis based on breast cancer risk factors such as age, race, breastfeeding, hormone replacement therapy, family history, and obesity was conducted on breast cancer patients using a new enhanced computerized database management system. My Structural Query Language (MySQL) is selected as the application for database management system to store the patient data collected from hospitals in Malaysia. An automatic calculation tool is embedded in this system to assist the data analysis. The r...

  16. ‘It was daunting’: Experience of women with a diagnosis of breast cancer attending for breast imaging

    International Nuclear Information System (INIS)

    Background: A quarter of cancer cases worldwide are attributed to breast cancer. Imaging plays an important role in diagnosis and care. Increasing value is placed on patient experience to inform service delivery. The main aim was to explore the experiences of women attending for diagnostic tests prior to and after diagnosis in order to inform practice. Methods: A convenience sample (n = 16) was recruited throughout the North-east of Scotland. A qualitative, exploratory and longitudinal study design was employed using semi-structured interviews. Twenty five interviews took place, with seven participants taking part in a single interview, a further seven and one participants taking part in two and three interviews respectively. Interviews were recorded, transcripts produced and analysed following the thematic approach. Results: Twelve participants attended imaging after discovering a breast lump and four via breast screening. Participants demonstrated differing attitudes to printed information material, and this changed over time. Imaging was ‘something to just get on and have done’ and almost without exception mammography was described as painful. The descriptions of invasive breast imaging provide a hitherto unknown insight into these procedures. Skill and attitude of staff was described as essential to the quality of the experience. This longitudinal study enabled women returning for follow-up procedures to identify their issues. Conclusion: This study provided a unique insight of the experiences of women when attending breast imaging. By listening to their narrative we can learn how services may be improved, and include this perspective to develop a quality patient-centred imaging service

  17. Ultra-wideband microwave imaging of breast cancer tumors via Bayesian inverse scattering

    Science.gov (United States)

    Fouda, A. E.; Teixeira, F. L.

    2014-02-01

    We develop a new algorithm for ultra-wideband (UWB) microwave imaging of breast cancer tumors using Bayesian inverse scattering. A key feature of the proposed algorithm is that constitutive properties of breast tissues are reconstructed from scattered UWB microwave signals together with the confidence level of the reconstruction. Having such confidence level enables minimization of both false alarms and missed detections. Results from the application of the proposed algorithm demonstrate the accuracy in estimating both location and permittivity of breast tumors without the need for a priori knowledge of pointwise properties of the background breast tissue.

  18. Drug delivery system and breast cancer cells

    Science.gov (United States)

    Colone, Marisa; Kaliappan, Subramanian; Calcabrini, Annarica; Tortora, Mariarosaria; Cavalieri, Francesca; Stringaro, Annarita

    2016-06-01

    Recently, nanomedicine has received increasing attention for its ability to improve the efficacy of cancer therapeutics. Nanosized polymer therapeutic agents offer the advantage of prolonged circulation in the blood stream, targeting to specific sites, improved efficacy and reduced side effects. In this way, local, controlled delivery of the drug will be achieved with the advantage of a high concentration of drug release at the target site while keeping the systemic concentration of the drug low, thus reducing side effects due to bioaccumulation. Various drug delivery systems such as nanoparticles, liposomes, microparticles and implants have been demonstrated to significantly enhance the preventive/therapeutic efficacy of many drugs by increasing their bioavailability and targetability. As these carriers significantly increase the therapeutic effect of drugs, their administration would become less cost effective in the near future. The purpose of our research work is to develop a delivery system for breast cancer cells using a microvector of drugs. These results highlight the potential uses of these responsive platforms suited for biomedical and pharmaceutical applications. At the request of all authors of the paper an updated version was published on 12 July 2016. The manuscript was prepared and submitted without Dr. Francesca Cavalieri's contribution and her name was added without her consent. Her name has been removed in the updated and re-published article.

  19. Content-based image retrieval utilizing explicit shape descriptors: applications to breast MRI and prostate histopathology

    Science.gov (United States)

    Sparks, Rachel; Madabhushi, Anant

    2011-03-01

    Content-based image retrieval (CBIR) systems, in the context of medical image analysis, allow for a user to compare a query image to previously archived database images in terms of diagnostic and/or prognostic similarity. CBIR systems can therefore serve as a powerful computerized decision support tool for clinical diagnostics and also serve as a useful learning tool for medical students, residents, and fellows. An accurate CBIR system relies on two components, (1) image descriptors which are related to a previously defined notion of image similarity and (2) quantification of image descriptors in order to accurately characterize and capture the a priori defined image similarity measure. In many medical applications, the morphology of an object of interest (e.g. breast lesions on DCE-MRI or glands on prostate histopathology) may provide important diagnostic and prognostic information regarding the disease being investigated. Morphological attributes can be broadly categorized as being (a) model-based (MBD) or (b) non-model based (NMBD). Most computerized decision support tools leverage morphological descriptors (e.g. area, contour variation, and compactness) which belong to the latter category in that they do not explicitly model morphology for the object of interest. Conversely, descriptors such as Fourier descriptors (FDs) explicitly model the object of interest. In this paper, we present a CBIR system that leverages a novel set of MBD called Explicit Shape Descriptors (ESDs) which accurately describe the similarity between the morphology of objects of interest. ESDs are computed by: (a) fitting shape models to objects of interest, (b) pairwise comparison between shape models, and (c) a nonlinear dimensionality reduction scheme to extract a concise set of morphological descriptors in a reduced dimensional embedding space. We utilized our ESDs in the context of CBIR in three datasets: (1) the synthetic MPEG-7 Set B containing 1400 silhouette images, (2) DCE-MRI of

  20. Breast histopathology image segmentation using spatio-colour-texture based graph partition method.

    Science.gov (United States)

    Belsare, A D; Mushrif, M M; Pangarkar, M A; Meshram, N

    2016-06-01

    This paper proposes a novel integrated spatio-colour-texture based graph partitioning method for segmentation of nuclear arrangement in tubules with a lumen or in solid islands without a lumen from digitized Hematoxylin-Eosin stained breast histology images, in order to automate the process of histology breast image analysis to assist the pathologists. We propose a new similarity based super pixel generation method and integrate it with texton representation to form spatio-colour-texture map of Breast Histology Image. Then a new weighted distance based similarity measure is used for generation of graph and final segmentation using normalized cuts method is obtained. The extensive experiments carried shows that the proposed algorithm can segment nuclear arrangement in normal as well as malignant duct in breast histology tissue image. For evaluation of the proposed method the ground-truth image database of 100 malignant and nonmalignant breast histology images is created with the help of two expert pathologists and the quantitative evaluation of proposed breast histology image segmentation has been performed. It shows that the proposed method outperforms over other methods. PMID:26708167

  1. Contralateral Prophylactic Mastectomy in the American College of Radiology Imaging Network 6667 Trial: Effect of Breast MR Imaging Assessments and Patient Characteristics

    OpenAIRE

    Rahbar, Habib; Hanna, Lucy G.; Gatsonis, Constantine; Mahoney, Mary C.; Schnall, Mitchell D.; DeMartini, Wendy B.; Lehman, Constance D.

    2014-01-01

    The results of this study suggest that patient factors and not breast MR imaging results significantly affect decisions by women with newly diagnosed breast cancer as to whether to undergo contralateral prophylactic mastectomy.

  2. A modified Seeded Region Growing algorithm for vessel segmentation in breast MRI images for investigating the nature of potential lesions

    Science.gov (United States)

    Glotsos, D.; Vassiou, K.; Kostopoulos, S.; Lavdas, El; Kalatzis, I.; Asvestas, P.; Arvanitis, D. L.; Fezoulidis, I. V.; Cavouras, D.

    2014-03-01

    The role of Magnetic Resonance Imaging (MRI) as an alternative protocol for screening of breast cancer has been intensively investigated during the past decade. Preliminary research results have indicated that gadolinium-agent administrative MRI scans may reveal the nature of breast lesions by analyzing the contrast-agent's uptake time. In this study, we attempt to deduce the same conclusion, however, from a different perspective by investigating, using image processing, the vascular network of the breast at two different time intervals following the administration of gadolinium. Twenty cases obtained from a 3.0-T MRI system (SIGNA HDx; GE Healthcare) were included in the study. A new modification of the Seeded Region Growing (SRG) algorithm was used to segment vessels from surrounding background. Delineated vessels were investigated by means of their topology, morphology and texture. Results have shown that it is possible to estimate the nature of the lesions with approximately 94.4% accuracy, thus, it may be claimed that the breast vascular network does encodes useful, patterned, information, which can be used for characterizing breast lesions.

  3. A modified Seeded Region Growing algorithm for vessel segmentation in breast MRI images for investigating the nature of potential lesions

    International Nuclear Information System (INIS)

    The role of Magnetic Resonance Imaging (MRI) as an alternative protocol for screening of breast cancer has been intensively investigated during the past decade. Preliminary research results have indicated that gadolinium-agent administrative MRI scans may reveal the nature of breast lesions by analyzing the contrast-agent's uptake time. In this study, we attempt to deduce the same conclusion, however, from a different perspective by investigating, using image processing, the vascular network of the breast at two different time intervals following the administration of gadolinium. Twenty cases obtained from a 3.0-T MRI system (SIGNA HDx; GE Healthcare) were included in the study. A new modification of the Seeded Region Growing (SRG) algorithm was used to segment vessels from surrounding background. Delineated vessels were investigated by means of their topology, morphology and texture. Results have shown that it is possible to estimate the nature of the lesions with approximately 94.4% accuracy, thus, it may be claimed that the breast vascular network does encodes useful, patterned, information, which can be used for characterizing breast lesions

  4. Body image issues after bilateral prophylactic mastectomy with breast reconstruction in healthy women at risk for hereditary breast cancer.

    Science.gov (United States)

    Gopie, Jessica P; Mureau, Marc A M; Seynaeve, Caroline; Ter Kuile, Moniek M; Menke-Pluymers, Marian B E; Timman, Reinier; Tibben, Aad

    2013-09-01

    The outcome of bilateral prophylactic mastectomy with breast reconstruction (BPM-IBR) in healthy BRCA1/2 mutation carriers can be potentially burdensome for body image and the intimate relationship. Therefore, in the current analysis the impact on body image, sexual and partner relationship satisfaction was prospectively investigated in women opting for BPM-IBR as well as cancer distress and general quality of life. Healthy women undergoing BPM-IBR completed questionnaires preoperatively (T0, n = 48), at 6 months (T1, n = 44) and after finishing breast reconstruction (median 21 months, range 12-35) (T2, n = 36). With multi-level regression analyses the course of outcome variables was investigated and a statistically significant change in body image and/or sexual and partner relationship satisfaction was predicted by baseline covariates. Body image significantly decreased at T1. At T2 sexual relationship satisfaction and body image tended to be lower compared to baseline. The overall partner relationship satisfaction did not significantly change. At T2, 37 % of the women reported that their breasts felt unpleasantly, 29 % was not satisfied with their breast appearance and 21 % felt embarrassed for their naked body. Most body image issues remained unchanged in 30 % of the women. A negative body image was predicted by high preoperative cancer distress. BPM-IBR was associated with adverse impact on body image in a substantial subgroup, but satisfaction with the overall sexual and partner relationship did not significantly change in time. The psychosocial impact of BPM-IBR in unaffected women should not be underestimated. Psychological support should ideally be integrated both before and after BPM-IBR. PMID:23224779

  5. Data-driven analysis of dynamic contrast-enhanced magnetic resonance imaging data in breast cancer diagnosis

    OpenAIRE

    Twellmann, Thorsten

    2005-01-01

    In the European Union, breast cancer is the most common type of cancer affecting women. If diagnosed in an early stage, breast cancer has an encouraging cure rate. Thus, early detection of breast cancer continues to be the key for an effective treatment. Recently, Dynamic Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI) has been identified as a valuable complementary technique for breast imaging. DCE-MRI has demonstrated to be highly sensitive for the detection of cancer, motivating the...

  6. Segmentation of the whole breast from low-dose chest CT images

    Science.gov (United States)

    Liu, Shuang; Salvatore, Mary; Yankelevitz, David F.; Henschke, Claudia I.; Reeves, Anthony P.

    2015-03-01

    The segmentation of whole breast serves as the first step towards automated breast lesion detection. It is also necessary for automatically assessing the breast density, which is considered to be an important risk factor for breast cancer. In this paper we present a fully automated algorithm to segment the whole breast in low-dose chest CT images (LDCT), which has been recommended as an annual lung cancer screening test. The automated whole breast segmentation and potential breast density readings as well as lesion detection in LDCT will provide useful information for women who have received LDCT screening, especially the ones who have not undergone mammographic screening, by providing them additional risk indicators for breast cancer with no additional radiation exposure. The two main challenges to be addressed are significant range of variations in terms of the shape and location of the breast in LDCT and the separation of pectoral muscles from the glandular tissues. The presented algorithm achieves robust whole breast segmentation using an anatomy directed rule-based method. The evaluation is performed on 20 LDCT scans by comparing the segmentation with ground truth manually annotated by a radiologist on one axial slice and two sagittal slices for each scan. The resulting average Dice coefficient is 0.880 with a standard deviation of 0.058, demonstrating that the automated segmentation algorithm achieves results consistent with manual annotations of a radiologist.

  7. Comparison of mammographic image quality in various methods of reconstructive breast surgery

    International Nuclear Information System (INIS)

    The purpose of our study was to evaluate mammographic image quality of various methods of reconstructive breast surgery with specific reference to the possibility of diagnosis of recurrent tumors. A total of 39 patients who underwent breast reconstruction following modified radical mastectomy were subject to clinical and mammographic examination. Three groups were formed: (a) autonomous tissue reconstruction (TRAM-flap; n=9), (b) submuscular silicon gel prostheses (n=21), and (c) supramuscular silicon gel prostheses (n=9). Mammographic images quality of the groups was compared by two radiologists working together using a point system where five specific criteria were valued and scored. The result was tabulated into three quality levels: good, acceptable, and limited. Mammograms were assessed as good, acceptable, or limited, respectively, as follows: group I: 7 (77.8%), 1 (11.1%), 1 (11.1%); group II; 4 (19%), 11 (52.4%), 6 (28.6%); group III: 3 (33.3%), 4 (44.5%), 2 (22.2%). The TRAM-flap method of reconstruction displays a high degree of mammographic image quality and therefore is preferable with respect to early diagnosis of recurrent tumors. (orig.)

  8. Comparison of mammographic image quality in various methods of reconstructive breast surgery

    Energy Technology Data Exchange (ETDEWEB)

    Lindbichler, F. [University Hospital, Graz (Austria). Dept. of Radiology; Hoflehner, H. [University Hospital, Graz (Austria). Dept. of Plastic and Reconstructive Surgery; Schmidt, F. [University Hospital, Graz (Austria). Dept. of Radiology; Pierer, G.R. [University Hospital, Graz (Austria). Dept. of Plastic and Reconstructive Surgery; Raith, J. [University Hospital, Graz (Austria). Dept. of Radiology; Umschaden, J. [University Hospital, Graz (Austria). Dept. of Plastic and Reconstructive Surgery; Preidler, K.W. [University Hospital, Graz (Austria). Dept. of Radiology

    1996-12-01

    The purpose of our study was to evaluate mammographic image quality of various methods of reconstructive breast surgery with specific reference to the possibility of diagnosis of recurrent tumors. A total of 39 patients who underwent breast reconstruction following modified radical mastectomy were subject to clinical and mammographic examination. Three groups were formed: (a) autonomous tissue reconstruction (TRAM-flap; n=9), (b) submuscular silicon gel prostheses (n=21), and (c) supramuscular silicon gel prostheses (n=9). Mammographic images quality of the groups was compared by two radiologists working together using a point system where five specific criteria were valued and scored. The result was tabulated into three quality levels: good, acceptable, and limited. Mammograms were assessed as good, acceptable, or limited, respectively, as follows: group I: 7 (77.8%), 1 (11.1%), 1 (11.1%); group II; 4 (19%), 11 (52.4%), 6 (28.6%); group III: 3 (33.3%), 4 (44.5%), 2 (22.2%). The TRAM-flap method of reconstruction displays a high degree of mammographic image quality and therefore is preferable with respect to early diagnosis of recurrent tumors. (orig.)

  9. Conceptual detector development and Monte Carlo simulation of a novel 3D breast computed tomography system

    Science.gov (United States)

    Ziegle, Jens; Müller, Bernhard H.; Neumann, Bernd; Hoeschen, Christoph

    2016-03-01

    A new 3D breast computed tomography (CT) system is under development enabling imaging of microcalcifications in a fully uncompressed breast including posterior chest wall tissue. The system setup uses a steered electron beam impinging on small tungsten targets surrounding the breast to emit X-rays. A realization of the corresponding detector concept is presented in this work and it is modeled through Monte Carlo simulations in order to quantify first characteristics of transmission and secondary photons. The modeled system comprises a vertical alignment of linear detectors hold by a case that also hosts the breast. Detectors are separated by gaps to allow the passage of X-rays towards the breast volume. The detectors located directly on the opposite side of the gaps detect incident X-rays. Mechanically moving parts in an imaging system increase the duration of image acquisition and thus can cause motion artifacts. So, a major advantage of the presented system design is the combination of the fixed detectors and the fast steering electron beam which enable a greatly reduced scan time. Thereby potential motion artifacts are reduced so that the visualization of small structures such as microcalcifications is improved. The result of the simulation of a single projection shows high attenuation by parts of the detector electronics causing low count levels at the opposing detectors which would require a flat field correction, but it also shows a secondary to transmission ratio of all counted X-rays of less than 1 percent. Additionally, a single slice with details of various sizes was reconstructed using filtered backprojection. The smallest detail which was still visible in the reconstructed image has a size of 0.2mm.

  10. Development and validation of a modelling framework for simulating 2D-mammography and breast tomosynthesis images.

    Science.gov (United States)

    Elangovan, Premkumar; Warren, Lucy M; Mackenzie, Alistair; Rashidnasab, Alaleh; Diaz, Oliver; Dance, David R; Young, Kenneth C; Bosmans, Hilde; Strudley, Celia J; Wells, Kevin

    2014-08-01

    Planar 2D x-ray mammography is generally accepted as the preferred screening technique used for breast cancer detection. Recently, digital breast tomosynthesis (DBT) has been introduced to overcome some of the inherent limitations of conventional planar imaging, and future technological enhancements are expected to result in the introduction of further innovative modalities. However, it is crucial to understand the impact of any new imaging technology or methodology on cancer detection rates and patient recall. Any such assessment conventionally requires large scale clinical trials demanding significant investment in time and resources. The concept of virtual clinical trials and virtual performance assessment may offer a viable alternative to this approach. However, virtual approaches require a collection of specialized modelling tools which can be used to emulate the image acquisition process and simulate images of a quality indistinguishable from their real clinical counterparts. In this paper, we present two image simulation chains constructed using modelling tools that can be used for the evaluation of 2D-mammography and DBT systems. We validate both approaches by comparing simulated images with real images acquired using the system being simulated. A comparison of the contrast-to-noise ratios and image blurring for real and simulated images of test objects shows good agreement ( < 9% error). This suggests that our simulation approach is a promising alternative to conventional physical performance assessment followed by large scale clinical trials. PMID:25029333

  11. Development and validation of a modelling framework for simulating 2D-mammography and breast tomosynthesis images

    International Nuclear Information System (INIS)

    Planar 2D x-ray mammography is generally accepted as the preferred screening technique used for breast cancer detection. Recently, digital breast tomosynthesis (DBT) has been introduced to overcome some of the inherent limitations of conventional planar imaging, and future technological enhancements are expected to result in the introduction of further innovative modalities. However, it is crucial to understand the impact of any new imaging technology or methodology on cancer detection rates and patient recall. Any such assessment conventionally requires large scale clinical trials demanding significant investment in time and resources. The concept of virtual clinical trials and virtual performance assessment may offer a viable alternative to this approach. However, virtual approaches require a collection of specialized modelling tools which can be used to emulate the image acquisition process and simulate images of a quality indistinguishable from their real clinical counterparts. In this paper, we present two image simulation chains constructed using modelling tools that can be used for the evaluation of 2D-mammography and DBT systems. We validate both approaches by comparing simulated images with real images acquired using the system being simulated. A comparison of the contrast-to-noise ratios and image blurring for real and simulated images of test objects shows good agreement ( < 9% error). This suggests that our simulation approach is a promising alternative to conventional physical performance assessment followed by large scale clinical trials. (paper)

  12. Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality

    International Nuclear Information System (INIS)

    The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of diffusion-weighted (DW) images. To evaluate geometric distortion, a comparison was made between lesion lengths derived from contrast enhanced MR (CE-MR) images and those obtained from the corresponding DW images. For assessment of image parameters, signal-to-noise ratio (SNR), lesion contrast, and contrast-to-noise ratio (CNR) were calculated. The rs-EPI was superior to ss-EPI in most criteria regarding the qualitative image quality. Anatomical structure distinction, delineation of the lesion, ghosting artifact, and overall image quality were significantly better in rs-EPI. Regarding the geometric distortion, lesion length on ss-EPI was significantly different from that of CE-MR, whereas there were no significant differences between CE-MR and rs-EPI. The rs-EPI was superior to ss-EPI in SNR and CNR. Readout-segmented EPI is superior to ss-EPI in the aspect of image quality in DW MR imaging of the breast

  13. Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yun Ju; Kim, Sung Hun; Kang, Bong Joo [Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of); Park, Chang Suk [Department of Radiology, Incheon St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Incheon 403-720 (Korea, Republic of); Kim, Hyeon Sook [Department of Radiology, St. Paul Hospital, College of Medicine, The Catholic University of Korea, Seoul 130-709 (Korea, Republic of); Son, Yo Han [Healthcare Sector, Siemens Ltd., Seoul 120-837 (Korea, Republic of); Porter, David Andrew [Healthcare Sector, Siemens AG, Erlangen 91050 (Germany); Song, Byung Joo [Department of General Surgery, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of)

    2014-07-01

    The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of diffusion-weighted (DW) images. To evaluate geometric distortion, a comparison was made between lesion lengths derived from contrast enhanced MR (CE-MR) images and those obtained from the corresponding DW images. For assessment of image parameters, signal-to-noise ratio (SNR), lesion contrast, and contrast-to-noise ratio (CNR) were calculated. The rs-EPI was superior to ss-EPI in most criteria regarding the qualitative image quality. Anatomical structure distinction, delineation of the lesion, ghosting artifact, and overall image quality were significantly better in rs-EPI. Regarding the geometric distortion, lesion length on ss-EPI was significantly different from that of CE-MR, whereas there were no significant differences between CE-MR and rs-EPI. The rs-EPI was superior to ss-EPI in SNR and CNR. Readout-segmented EPI is superior to ss-EPI in the aspect of image quality in DW MR imaging of the breast.

  14. Generic image matching system

    Science.gov (United States)

    Liang, Zhongjie T.

    1992-05-01

    The generic imaging matching system (GIMS) provides an optimal systematic solution to any problem of color image processing in printing and publishing that can be classified as or modeled to the generic image matching problem defined. Typical GIMS systems/processes include color matching from different output devices, color conversion, color correction, device calibration, colorimetric scanner, colorimetric printer, colorimetric color reproduction, and image interpolation from scattered data. GIMS makes color matching easy for the user and maximizes operational flexibility allowing the user to obtain the degree of match wanted while providing the capability to achieve the best balance with respect to the human perception of color, color fidelity, and preservation of image information and color contrast. Instead of controlling coefficients in a transformation formula, GIMS controls the mapping directly in a standard device-independent color space, so that color can be matched, conceptually, to the highest possible accuracy. An optimization algorithm called modified vector shading was developed to minimize the matching error and to perform a 'near-neighborhood' gamut compression. An automatic error correction algorithm with a multidirection searching procedure using correlated re-initialization was developed to avoid local minimum failures. Once the mapping for color matching is generated, it can be utilized by a multidimensional linear interpolator with a small look-up-table (LUT) implemented by either software, a hardware interpolator or a digital-signal-processor.

  15. Image reconstruction for a Positron Emission Tomograph optimized for breast cancer imaging

    International Nuclear Information System (INIS)

    The author performs image reconstruction for a novel Positron Emission Tomography camera that is optimized for breast cancer imaging. This work addresses for the first time, the problem of fully-3D, tomographic reconstruction using a septa-less, stationary, (i.e. no rotation or linear motion), and rectangular camera whose Field of View (FOV) encompasses the entire volume enclosed by detector modules capable of measuring Depth of Interaction (DOI) information. The camera is rectangular in shape in order to accommodate breasts of varying sizes while allowing for soft compression of the breast during the scan. This non-standard geometry of the camera exacerbates two problems: (a) radial elongation due to crystal penetration and (b) reconstructing images from irregularly sampled data. Packing considerations also give rise to regions in projection space that are not sampled which lead to missing information. The author presents new Fourier Methods based image reconstruction algorithms that incorporate DOI information and accommodate the irregular sampling of the camera in a consistent manner by defining lines of responses (LORs) between the measured interaction points instead of rebinning the events into predefined crystal face LORs which is the only other method to handle DOI information proposed thus far. The new procedures maximize the use of the increased sampling provided by the DOI while minimizing interpolation in the data. The new algorithms use fixed-width evenly spaced radial bins in order to take advantage of the speed of the Fast Fourier Transform (FFT), which necessitates the use of irregular angular sampling in order to minimize the number of unnormalizable Zero-Efficiency Bins (ZEBs). In order to address the persisting ZEBs and the issue of missing information originating from packing considerations, the algorithms (a) perform nearest neighbor smoothing in 2D in the radial bins (b) employ a semi-iterative procedure in order to estimate the unsampled data

  16. Image reconstruction for a Positron Emission Tomograph optimized for breast cancer imaging

    Energy Technology Data Exchange (ETDEWEB)

    Virador, Patrick R.G.

    2000-04-01

    The author performs image reconstruction for a novel Positron Emission Tomography camera that is optimized for breast cancer imaging. This work addresses for the first time, the problem of fully-3D, tomographic reconstruction using a septa-less, stationary, (i.e. no rotation or linear motion), and rectangular camera whose Field of View (FOV) encompasses the entire volume enclosed by detector modules capable of measuring Depth of Interaction (DOI) information. The camera is rectangular in shape in order to accommodate breasts of varying sizes while allowing for soft compression of the breast during the scan. This non-standard geometry of the camera exacerbates two problems: (a) radial elongation due to crystal penetration and (b) reconstructing images from irregularly sampled data. Packing considerations also give rise to regions in projection space that are not sampled which lead to missing information. The author presents new Fourier Methods based image reconstruction algorithms that incorporate DOI information and accommodate the irregular sampling of the camera in a consistent manner by defining lines of responses (LORs) between the measured interaction points instead of rebinning the events into predefined crystal face LORs which is the only other method to handle DOI information proposed thus far. The new procedures maximize the use of the increased sampling provided by the DOI while minimizing interpolation in the data. The new algorithms use fixed-width evenly spaced radial bins in order to take advantage of the speed of the Fast Fourier Transform (FFT), which necessitates the use of irregular angular sampling in order to minimize the number of unnormalizable Zero-Efficiency Bins (ZEBs). In order to address the persisting ZEBs and the issue of missing information originating from packing considerations, the algorithms (a) perform nearest neighbor smoothing in 2D in the radial bins (b) employ a semi-iterative procedure in order to estimate the unsampled data

  17. Investigation of a scanned cylindrical ultrasound system for breast hyperthermia

    International Nuclear Information System (INIS)

    This paper investigates the feasibility of a scanned cylindrical ultrasound system for producing uniform heating from the central to the superficial portions of the breast or localized heating within the breast at a specific location. The proposed system consists of plane ultrasound transducer(s) mounted on a scanned cylindrical support. The breast was immersed in water and surrounded by this system during the treatment. The control parameters considered are the size of the transducer, the ultrasound frequency, the scan angle and the shifting distance between the axes of the breast and the system. Three-dimensional acoustical and thermal models were used to calculate the temperature distribution. Non-perfused phantom experiments were performed to verify the simulation results. Simulation results indicate that high frequency ultrasound could be used for the superficial heating, and the scan angle of the transducer could be varied to obtain an appropriate high temperature region to cover the desired treatment region. Low frequency ultrasound could be used for deep heating and the high temperature region could be moved by shifting the system. In addition, a combination of low and high frequency ultrasound could result in a portion treatment from the central to the superficial breast or an entire breast treatment. Good agreement was obtained between non-perfused experiments and simulation results. The findings of this study can be used to determine the effects of the control parameters of this system, as well as to select the optimal parameters for a specific treatment

  18. Breast density quantification using magnetic resonance imaging (MRI) with bias field correction: A postmortem study

    International Nuclear Information System (INIS)

    Purpose: Quantification of breast density based on three-dimensional breast MRI may provide useful information for the early detection of breast cancer. However, the field inhomogeneity can severely challenge the computerized image segmentation process. In this work, the effect of the bias field in breast density quantification has been investigated with a postmortem study. Methods: T1-weighted images of 20 pairs of postmortem breasts were acquired on a 1.5 T breast MRI scanner. Two computer-assisted algorithms were used to quantify the volumetric breast density. First, standard fuzzy c-means (FCM) clustering was used on raw images with the bias field present. Then, the coherent local intensity clustering (CLIC) method estimated and corrected the bias field during the iterative tissue segmentation process. Finally, FCM clustering was performed on the bias-field-corrected images produced by CLIC method. The left–right correlation for breasts in the same pair was studied for both segmentation algorithms to evaluate the precision of the tissue classification. Finally, the breast densities measured with the three methods were compared to the gold standard tissue compositions obtained from chemical analysis. The linear correlation coefficient, Pearson'sr, was used to evaluate the two image segmentation algorithms and the effect of bias field. Results: The CLIC method successfully corrected the intensity inhomogeneity induced by the bias field. In left–right comparisons, the CLIC method significantly improved the slope and the correlation coefficient of the linear fitting for the glandular volume estimation. The left–right breast density correlation was also increased from 0.93 to 0.98. When compared with the percent fibroglandular volume (%FGV) from chemical analysis, results after bias field correction from both the CLIC the FCM algorithms showed improved linear correlation. As a result, the Pearson'sr increased from 0.86 to 0.92 with the bias field correction

  19. Multispectral Panoramic Imaging System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — International Electronic Machines Corporation, a leader in the design of precision imaging systems, will develop an innovative multispectral, panoramic imaging...

  20. X-ray attenuation of adipose breast tissue: in-vitro and in-vivo measurements using spectral imaging

    Science.gov (United States)

    Fredenberg, Erik; Erhard, Klaus; Berggren, Karl; Dance, David R.; Young, Kenneth C.; Cederström, Björn; Johansson, Henrik; Lundqvist, Mats; Moa, Elin; Homan, Hanno; Willsher, Paula; Kilburn-Toppin, Fleur; Wallis, Matthew

    2015-03-01

    The development of new x-ray imaging techniques often requires prior knowledge of tissue attenuation, but the sources of such information are sparse. We have measured the attenuation of adipose breast tissue using spectral imaging, in vitro and in vivo. For the in-vitro measurement, fixed samples of adipose breast tissue were imaged on a spectral mammography system, and the energy-dependent x-ray attenuation was measured in terms of equivalent thicknesses of aluminum and poly-methyl methacrylate (PMMA). For the in-vivo measurement, a similar procedure was applied on a number of spectral screening mammograms. The results of the two measurements agreed well and were consistent with published attenuation data and with measurements on tissue-equivalent material.

  1. Image and pathological changes after microwave ablation of breast cancer: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Wenbin [Department of Breast Surgery, The First Affiliated Hospital, Nanjing Medical University, 300 Guangzhou Road, Nanjing 210029 (China); Jiang, Yanni [Department of Radiology, The First Affiliated Hospital, Nanjing Medical University, 300 Guangzhou Road, Nanjing 210029 (China); Chen, Lin; Ling, Lijun; Liang, Mengdi; Pan, Hong [Department of Breast Surgery, The First Affiliated Hospital, Nanjing Medical University, 300 Guangzhou Road, Nanjing 210029 (China); Wang, Siqi [Department of Radiology, The First Affiliated Hospital, Nanjing Medical University, 300 Guangzhou Road, Nanjing 210029 (China); Ding, Qiang [Department of Breast Surgery, The First Affiliated Hospital, Nanjing Medical University, 300 Guangzhou Road, Nanjing 210029 (China); Liu, Xiaoan, E-mail: liuxiaoan@126.com [Department of Breast Surgery, The First Affiliated Hospital, Nanjing Medical University, 300 Guangzhou Road, Nanjing 210029 (China); Wang, Shui, E-mail: ws0801@hotmail.com [Department of Breast Surgery, The First Affiliated Hospital, Nanjing Medical University, 300 Guangzhou Road, Nanjing 210029 (China)

    2014-10-15

    Highlights: • We report successful experience of MWA in breast cancer under local anesthesia. • We report MR imaging evaluation of microwave ablation zone in breast cancer. • Pathological changes after microwave ablation in breast cancer was reported. • 2 min MWA caused an ablation zone with three diameters > 2 cm in breast cancer. - Abstract: Purpose: To prospectively assess MR imaging evaluation of the ablation zone and pathological changes after microwave ablation (MWA) in breast cancer. Materials and methods: Twelve enrolled patients, diagnosed with non-operable locally advanced breast cancer (LABC), were treated by MWA and then neoadjuvant chemotherapy, followed by surgery. MR imaging was applied to evaluate the effect of MWA. Hematoxylin-eosin (HE) staining and transmission electron microscopy (TEM) were applied to analyze the ablated area. Results: All MWA procedures were performed successfully under local anesthesia. For a mean duration of 2.15 min, the mean largest, middle and smallest diameters in the ablated zone 24-h post-ablation in MR imaging were 2.98 cm ± 0.53, 2.51 cm ± 0.41 and 2.23 cm ± 0.41, respectively. The general shape of the ablation zone was close to a sphere. The ablated area became gradually smaller in MR imaging. No adverse effects related to MWA were noted in all 12 patients during and after MWA. HE staining could confirm the effect about 3 months after MWA, which was confirmed by TEM. Conclusions: 2 min MWA can cause an ablation zone with three diameters larger than 2 cm in breast cancer, which may be suitable for the local treatment of breast cancer up to 2 cm in largest diameter. However, the long-term effect of MWA in the treatment of small breast cancer should be determined in the future.

  2. Image and pathological changes after microwave ablation of breast cancer: A pilot study

    International Nuclear Information System (INIS)

    Highlights: • We report successful experience of MWA in breast cancer under local anesthesia. • We report MR imaging evaluation of microwave ablation zone in breast cancer. • Pathological changes after microwave ablation in breast cancer was reported. • 2 min MWA caused an ablation zone with three diameters > 2 cm in breast cancer. - Abstract: Purpose: To prospectively assess MR imaging evaluation of the ablation zone and pathological changes after microwave ablation (MWA) in breast cancer. Materials and methods: Twelve enrolled patients, diagnosed with non-operable locally advanced breast cancer (LABC), were treated by MWA and then neoadjuvant chemotherapy, followed by surgery. MR imaging was applied to evaluate the effect of MWA. Hematoxylin-eosin (HE) staining and transmission electron microscopy (TEM) were applied to analyze the ablated area. Results: All MWA procedures were performed successfully under local anesthesia. For a mean duration of 2.15 min, the mean largest, middle and smallest diameters in the ablated zone 24-h post-ablation in MR imaging were 2.98 cm ± 0.53, 2.51 cm ± 0.41 and 2.23 cm ± 0.41, respectively. The general shape of the ablation zone was close to a sphere. The ablated area became gradually smaller in MR imaging. No adverse effects related to MWA were noted in all 12 patients during and after MWA. HE staining could confirm the effect about 3 months after MWA, which was confirmed by TEM. Conclusions: 2 min MWA can cause an ablation zone with three diameters larger than 2 cm in breast cancer, which may be suitable for the local treatment of breast cancer up to 2 cm in largest diameter. However, the long-term effect of MWA in the treatment of small breast cancer should be determined in the future

  3. Breast imaging reports for malignant lesions: are we maintaining recommended BI-RADS® lexicon standards?

    Directory of Open Access Journals (Sweden)

    Masroor I

    2012-11-01

    Full Text Available Imrana Masroor,1 Muhammad Azeemuddin,1 Saima Sakhawat,1 Madiha Beg,1 Saba Sohail,2 Rashid Ahmed,3 Irfan-Ul-Haq,4 Javed Mehboob51Radiology Department, Aga Khan University Hospital, 2Radiology Department, Civil Hospital, 3Advanced Radiology Clinic, 4Radiology Department, Pakistan Naval Station Shifa Hospital, 5Karachi Institute of Radiotherapy and Nuclear Medicine, Karachi, PakistanBackground: The purpose of this study was to evaluate mammography reports for diagnosed breast cancer cases in major government and private centers in Karachi, Pakistan, with respect to concordance with the Breast Imaging Reports And Data System (BI-RADS® lexicon.Methods: A prospective, descriptive, multicenter study was conducted in the radiology sections of the Aga Khan University Hospital, Pakistan Naval Station Shifa Hospital, Advanced Radiology Clinic, Karachi Institute of Radiotherapy and Nuclear Medicine, and Civil Hospital Karachi between May and October 2010 after approval from the ethical review committee of Aga Khan University. Mammograms reported as BI-RADS category 4 and 5 were included in the study. Mammograms reported as BI-RADS category 0, 1, 2 and 3 were excluded. Fifty reports were collected from each center. Data were collected about the clinical indication, breast density, location and description of the lesion, calcification, and comments on axillary lymph nodes. This description was compared with the BI-RADS lexicon.Results: The mean age of the patients was 50 ± 12 years. The clinical indication, breast parenchymal density, lesion location, and presence of calcification were better described by the private centers, while description of lymph node status was better stated by the government centers. This difference was statistically significant, except for lesion description. The description of masses by the two reporting groups was comparable.Conclusion: Mammographic reporting of malignant breast lesions in the private sector is more in line with

  4. Quantitative Luminescence Imaging System

    International Nuclear Information System (INIS)

    The goal of the MEASUREMENT OF CHEMILUMINESCENCE project is to develop and deliver a suite of imaging radiometric instruments for measuring spatial distributions of chemiluminescence. Envisioned deliverables include instruments working at the microscopic, macroscopic, and life-sized scales. Both laboratory and field portable instruments are envisioned. The project also includes development of phantoms as enclosures for the diazoluminomelanin (DALM) chemiluminescent chemistry. A suite of either phantoms in a variety of typical poses, or phantoms that could be adjusted to a variety of poses, is envisioned. These are to include small mammals (rats), mid-sized mammals (monkeys), and human body parts. A complete human phantom that can be posed is a long-term goal of the development. Taken together, the chemistry and instrumentation provide a means for imaging rf dosimetry based on chemiluminescence induced by the heat resulting from rf energy absorption. The first delivered instrument, the Quantitative Luminescence Imaging System (QLIS), resulted in a patent, and an R ampersand D Magazine 1991 R ampersand D 100 award, recognizing it as one of the 100 most significant technological developments of 1991. The current status of the project is that three systems have been delivered, several related studies have been conducted, two preliminary human hand phantoms have been delivered, system upgrades have been implemented, and calibrations have been maintained. Current development includes sensitivity improvements to the microscope-based system; extension of the large-scale (potentially life-sized targets) system to field portable applications; extension of the 2-D large-scale system to 3-D measurement; imminent delivery of a more refined human hand phantom and a rat phantom; rf, thermal and imaging subsystem integration; and continued calibration and upgrade support

  5. Value of real-time compound US in diagnosis of malignant tumor in breast comparing with conventional US, and pulse inversion harmonic images

    International Nuclear Information System (INIS)

    To compare the usefulness of real-time compound US (RCUS) with that of conventional US (CUS) and pulse inversion harmonic (PIH) imaging in the diagnosis of malignant breast tumors. In 22 female patients whose mean age was 49 years, we evaluated the RCUS findings of pathologically proven [core biopsy (n=9), mammotome tissue biopsy (n=10)], excisional biopsy (n=3) malignant breast tumors, comparing them with the findings of CUS and PIH imaging. Evaluation of these masses was in terms of their marginal distinction, internal echogenicity, boundary and posterior echo pattern, relationship with the adjacent lactiferous ductal system, and the presence of necrosis (12/22) and calcification (6/22). In terms of marginal distinction, internal echogenicity, boundary echo patterns, and the relationship with adjacent ductal system, RCUS was superior to both conventional US and PIH imaging (p<0.05). For the diagnosis of malignant breast tumors RCUS was more useful than CUS or PIH imaging

  6. Basic research and clinical application of optical molecular imaging in breast cancer

    International Nuclear Information System (INIS)

    As a rapidly developing biomedical imaging technology,in vivo optical molecular imaging has been widely applied in various research fields owing to its unique real-time, quantitative and noninvasive characteristics. The applications of in vivo optical imaging technology in the basic and clinical research of breast cancer were reviewed, including detection of distant metastasis,tumor apoptosis, cell cycle, hypoxia and angiogenesis, ER-mediated molecular pathway, breast cancer stem cells, early diagnosis, sentinel node biopsy, evaluation of drug efficacy and detection of human epidermal growth factor receptor-2 (HER-2) expression. They all seem to have a promising potential in in vivo optical molecular imaging. (authors)

  7. The effect of breast composition on absorbed dose and image contrast

    International Nuclear Information System (INIS)

    We have studied the effect of breast composition on the average whole breast dose, average glandular dose, and image contrast in mammography, using both computational and experimental methods. Three glandular/adipose compositions were considered: 30/70, 50/50, and 70/30 by weight, for both 3- and 5-cm breast thickness. Absorbed dose was found to increase with greater glandular content and this increase is more pronounced for thick breasts and softer beams. For typical screen-film x-ray beams, the average dose to a highly glandular breast is nearly twice the dose to a highly adipose breast and the average glandular dose about 40% higher. Dose was reduced when higher energy beams were employed. The use of a grid increased the dose by a factor of 2.0 to 2.6. Finally, the measured image contrast decreases with increasing breast glandularity, to a greater extent in small breasts and when low energy beams were employed

  8. Using image simulation to test the effect of detector type on breast cancer detection

    Science.gov (United States)

    Mackenzie, Alistair; Warren, Lucy M.; Dance, David R.; Chakraborty, Dev P.; Cooke, Julie; Halling-Brown, Mark D.; Looney, Padraig T.; Wallis, Matthew G.; Given-Wilson, Rosalind M.; Alexander, Gavin G.; Young, Kenneth C.

    2014-03-01

    Introduction: The effect that the image quality associated with different image receptors has on cancer detection in mammography was measured using a novel method for changing the appearance of images. Method: A set of 270 mammography cases (one view, both breasts) was acquired using five Hologic Selenia and two Hologic Dimensions X-ray sets: 160 normal cases, 80 cases with subtle real non-calcification malignant lesions and 30 cases with biopsy proven benign lesions. Simulated calcification clusters were inserted into half of the normal cases. The 270 cases (Arm 1) were converted to appear as if they had been acquired on three other imaging systems: caesium iodide detector (Arm 2), needle image plate computed radiography (CR) (Arm 3) and powder phosphor CR (Arm 4). Five experienced mammography readers marked the location of suspected cancers in the images and classified the degree of visibility of the lesions. Statistical analysis was performed using JAFROC. Results: The differences in the visibility of calcification clusters between all pairs of arms were statistically significant (plesions was smaller than for calcification clusters, but the differences were still significant except between Arms 1 and 2 and between Arms 3 and 4. Conclusion: Detector type had a significant impact on the visibility of all types of subtle cancers, with the largest impact being on the visibility of calcification clusters.

  9. Primary application of 99Tcm-octreotide imaging in the diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Objective: To evaluate the clinical value of 99Tcm-octreotide scintigraphy in the diagnosis of breast cancer. Methods: 99Tcm-octreotide and 99Tcm-methoxyisobutylisonitrile (MIBI) imaging were performed on 36 patients with breast masses confirmed by pathology (19 patients with breast cancer and 17 benign lesions) . The imaging was read as positive when focal radioactivity increased in the breast both on 99Tcm-octreotide and 99Tcm-MIBI imaging. The uptake ratios (UR) of lesion (L) to normal (N) were calculated after 99Tcm-MIBI injection at 10-15 min and 99Tcm-octreotide injection at different time points (5-10 min, 60-90 min and 180 min). Results: The sensitivity of 99Tcm-octreotide imaging in the diagnosis of primary breast cancer was lower than that of 99Tcm-MIBI (68.4% vs 94.7%, P99Tcm-octreotide and 99Tcm-MIBI (83.3% and 86.1%, respectively, P>0.05). Conclusion: Comparing with 99Tcm-MIBI 99Tcm-octreotide imaging showed a higher specificity and the same accuracy in the diagnosis of breast cancer

  10. Conspicuity of breast cancer according to histopathological type and breast density when imaged by full-field digital mammography compared with screen-film mammography

    International Nuclear Information System (INIS)

    To compare the conspicuity of different histopathological types of breast cancer according to breast density and mammographic imaging in patients with screen-detected breast cancers undergoing both full-field digital mammography (FFDM) and screen-film mammography (SFM) in the United Kingdom National Health Service Breast Screening Programme (NHSBSP). 185 patients underwent routine screening with SFM followed by further imaging using FFDM with consequent diagnosis of breast cancer. All SFM and soft-copy FFDM images were evaluated by two readers in an independent, retrospective review. The visualisation and conspicuity of the mammographic abnormality were recorded and graded using a four-level scale. Conspicuity of breast cancer was qualitatively evaluated. Breast density and conspicuity were correlated with histopathological diagnosis and inter-observer correlation was calculated. Mixed Model ANOVA demonstrated significant differences between FFDM and SFM (p < 0.001) and breast densities (p = 0.009): conspicuity of the mammographic abnormality (p < 0.001) and visualisation of the dominant mammographic feature (p < 0.001) were significantly greater with FFDM than SFM. This held true for both readers and for all histopathological tumour types with no significant differences between each tumour type. FFDM is significantly superior to SFM for conspicuity of screen-detected breast cancers for all histopathological types and breast densities. (orig.)

  11. Conspicuity of breast cancer according to histopathological type and breast density when imaged by full-field digital mammography compared with screen-film mammography

    Energy Technology Data Exchange (ETDEWEB)

    Pinker, Katja [Medical University Vienna, Department of Radiology, Divison of Molecular and Gender Imaging, Vienna (Austria); Medical University Vienna, Department of Radiology, MR Centre of Excellence, Vienna (Austria); Perry, Nicholas [St Bartholomew' s Hospital, Breast Unit, Barts and The London Cancer Centre, London (United Kingdom); The Princess Grace Hospital, The London Breast Institute, London (United Kingdom); Vinnicombe, S.; Shiel, S. [St Bartholomew' s Hospital, Breast Unit, Barts and The London Cancer Centre, London (United Kingdom); Weber, M. [Medical University Vienna, Department of Radiology, Vienna (Austria)

    2011-01-15

    To compare the conspicuity of different histopathological types of breast cancer according to breast density and mammographic imaging in patients with screen-detected breast cancers undergoing both full-field digital mammography (FFDM) and screen-film mammography (SFM) in the United Kingdom National Health Service Breast Screening Programme (NHSBSP). 185 patients underwent routine screening with SFM followed by further imaging using FFDM with consequent diagnosis of breast cancer. All SFM and soft-copy FFDM images were evaluated by two readers in an independent, retrospective review. The visualisation and conspicuity of the mammographic abnormality were recorded and graded using a four-level scale. Conspicuity of breast cancer was qualitatively evaluated. Breast density and conspicuity were correlated with histopathological diagnosis and inter-observer correlation was calculated. Mixed Model ANOVA demonstrated significant differences between FFDM and SFM (p < 0.001) and breast densities (p = 0.009): conspicuity of the mammographic abnormality (p < 0.001) and visualisation of the dominant mammographic feature (p < 0.001) were significantly greater with FFDM than SFM. This held true for both readers and for all histopathological tumour types with no significant differences between each tumour type. FFDM is significantly superior to SFM for conspicuity of screen-detected breast cancers for all histopathological types and breast densities. (orig.)

  12. Factors Associated with Preoperative Magnetic Resonance Imaging Use among Medicare Beneficiaries with Nonmetastatic Breast Cancer.

    Science.gov (United States)

    Henderson, Louise M; Weiss, Julie; Hubbard, Rebecca A; O'Donoghue, Cristina; DeMartini, Wendy B; Buist, Diana S M; Kerlikowske, Karla; Goodrich, Martha; Virnig, Beth; Tosteson, Anna N A; Lehman, Constance D; Onega, Tracy

    2016-01-01

    Preoperative breast magnetic resonance imaging (MRI) use among Medicare beneficiaries with breast cancer has substantially increased from 2005 to 2009. We sought to identify factors associated with preoperative breast MRI use among women diagnosed with ductal carcinoma in situ (DCIS) or stage I-III invasive breast cancer (IBC). Using Surveillance, Epidemiology, and End Results and Medicare data from 2005 to 2009 we identified women ages 66 and older with DCIS or stage I-III IBC who underwent breast-conserving surgery or mastectomy. We compared preoperative breast MRI use by patient, tumor and hospital characteristics stratified by DCIS and IBC using multivariable logistic regression. From 2005 to 2009, preoperative breast MRI use increased from 5.9% to 22.4% of women diagnosed with DCIS and 7.0% to 24.3% of women diagnosed with IBC. Preoperative breast MRI use was more common among women who were younger, married, lived in higher median income zip codes and had no comorbidities. Among women with IBC, those with lobular disease, smaller tumors (2 cm). The likelihood of receiving preoperative breast MRI is similar for women diagnosed with DCIS and IBC. Use of MRI is more common in women with IBC for tumors that are lobular and smaller while for DCIS MRI is used for evaluation of larger lesions. PMID:26511204

  13. Cerenkov luminescence imaging of human breast cancer: a Monte Carlo simulations study

    Science.gov (United States)

    Boschi, F.; Pagliazzi, M.; Spinelli, A. E.

    2016-03-01

    Cerenkov luminescence imaging (CLI) is a novel molecular imaging technique based on the detection of Cerenkov light produced by beta particles traveling through biological tissues. In this paper we simulated using 18F and 90Y the possibility of detecting Cerenkov luminescence in human breast tissues, in order to evaluate the potential of the CLI technique in a clinical setting. A human breast digital phantom was obtained from an 18F-FDG CT-PET scan. The spectral features of the breast surface emission were obtained as well as the simulated images obtainable by a cooled CCD detector. The simulated images revealed a signal to noise ratio equal to 6 for a 300 s of acquisition time. We concluded that a dedicated human Cerenkov imaging detector can be designed in order to offer a valid low cost alternative to diagnostic techniques in nuclear medicine, in particular allowing the detection of beta-minus emitters used in radiotherapy.

  14. Cerenkov luminescence imaging of human breast cancer: a Monte Carlo simulations study

    International Nuclear Information System (INIS)

    Cerenkov luminescence imaging (CLI) is a novel molecular imaging technique based on the detection of Cerenkov light produced by beta particles traveling through biological tissues. In this paper we simulated using 18F and 90Y the possibility of detecting Cerenkov luminescence in human breast tissues, in order to evaluate the potential of the CLI technique in a clinical setting. A human breast digital phantom was obtained from an 18F-FDG CT-PET scan. The spectral features of the breast surface emission were obtained as well as the simulated images obtainable by a cooled CCD detector. The simulated images revealed a signal to noise ratio equal to 6 for a 300 s of acquisition time. We concluded that a dedicated human Cerenkov imaging detector can be designed in order to offer a valid low cost alternative to diagnostic techniques in nuclear medicine, in particular allowing the detection of beta-minus emitters used in radiotherapy

  15. Imaging the lymphatic system

    OpenAIRE

    Munn, Lance L.; Padera, Timothy P

    2014-01-01

    Visualization of the lymphatic system is clinically necessary during diagnosis or treatment of many conditions and diseases; it is used for identifying and monitoring lymphedema, for detecting metastatic lesions during cancer staging and for locating lymphatic structures so they can be spared during surgical procedures. Imaging lymphatic anatomy and function also plays an important role in experimental studies of lymphatic development and function, where spatial resolution and accessibility a...

  16. Molecular Imaging in Breast Cancer: From Whole-Body PET/CT to Dedicated Breast PET

    Directory of Open Access Journals (Sweden)

    B. B. Koolen

    2012-01-01

    Full Text Available Positron emission tomography (PET, with or without integrated computed tomography (CT, using 18F-fluorodeoxyglucose (FDG is based on the principle of elevated glucose metabolism in malignant tumors, and its use in breast cancer patients is frequently being investigated. It has been shown useful for classification, staging, and response monitoring, both in primary and recurrent disease. However, because of the partial volume effect and limited resolution of most whole-body PET scanners, sensitivity for the visualization of small tumors is generally low. To improve the detection and quantification of primary breast tumors with FDG PET, several dedicated breast PET devices have been developed. In this nonsystematic review, we shortly summarize the value of whole-body PET/CT in breast cancer and provide an overview of currently available dedicated breast PETs.

  17. Imaging system fundamentals

    Science.gov (United States)

    Holst, Gerald C.

    2011-05-01

    Point-and-shoot, TV studio broadcast, and thermal infrared imaging cameras have significantly different applications. A parameter that applies to all imaging systems is Fλ/d, where F is the focal ratio, λ is the wavelength, and d is the detector size. Fλ/d uniquely defines the shape of the camera modulation transfer function. When Fλ/dcorrupts the imagery. Mathematically, the worst case analysis assumes that the scene contains all spatial frequencies with equal amplitudes. This quantifies the potential for aliasing and is called the spurious response. Digital data cannot be seen; it resides in a computer. Cathode ray tubes, flat panel displays, and printers convert the data into an analog format and are called reconstruction filters. The human visual system is an additional reconstruction filter. Different displays and variable viewing distance affect the perceived image quality. Simulated imagery illustrates different Fλ/d ratios, displays, and sampling artifacts. Since the human visual system is primarily sensitive to intensity variations, aliasing (a spatial frequency phenomenon) is not considered bothersome in most situations.

  18. Matching methods evaluation framework for stereoscopic breast x-ray images.

    Science.gov (United States)

    Rousson, Johanna; Naudin, Mathieu; Marchessoux, Cédric

    2016-01-01

    Three-dimensional (3-D) imaging has been intensively studied in the past few decades. Depth information is an important added value of 3-D systems over two-dimensional systems. Special focuses were devoted to the development of stereo matching methods for the generation of disparity maps (i.e., depth information within a 3-D scene). Dedicated frameworks were designed to evaluate and rank the performance of different stereo matching methods but never considering x-ray medical images. Yet, 3-D x-ray acquisition systems and 3-D medical displays have already been introduced into the diagnostic market. To access the depth information within x-ray stereoscopic images, computing accurate disparity maps is essential. We aimed at developing a framework dedicated to x-ray stereoscopic breast images used to evaluate and rank several stereo matching methods. A multiresolution pyramid optimization approach was integrated to the framework to increase the accuracy and the efficiency of the stereo matching techniques. Finally, a metric was designed to score the results of the stereo matching compared with the ground truth. Eight methods were evaluated and four of them [locally scaled sum of absolute differences (LSAD), zero mean sum of absolute differences, zero mean sum of squared differences, and locally scaled mean sum of squared differences] appeared to perform equally good with an average error score of 0.04 (0 is the perfect matching). LSAD was selected for generating the disparity maps. PMID:26587552

  19. A nonlinear biomechanical model based registration method for aligning prone and supine MR breast images.

    Science.gov (United States)

    Han, Lianghao; Hipwell, John H; Eiben, Björn; Barratt, Dean; Modat, Marc; Ourselin, Sebastien; Hawkes, David J

    2014-03-01

    Preoperative diagnostic magnetic resonance (MR) breast images can provide good contrast between different tissues and 3-D information about suspicious tissues. Aligning preoperative diagnostic MR images with a patient in the theatre during breast conserving surgery could assist surgeons in achieving the complete excision of cancer with sufficient margins. Typically, preoperative diagnostic MR breast images of a patient are obtained in the prone position, while surgery is performed in the supine position. The significant shape change of breasts between these two positions due to gravity loading, external forces and related constraints makes the alignment task extremely difficult. Our previous studies have shown that either nonrigid intensity-based image registration or biomechanical modelling alone are limited in their ability to capture such a large deformation. To tackle this problem, we proposed in this paper a nonlinear biomechanical model-based image registration method with a simultaneous optimization procedure for both the material parameters of breast tissues and the direction of the gravitational force. First, finite element (FE) based biomechanical modelling is used to estimate a physically plausible deformation of the pectoral muscle and the major deformation of breast tissues due to gravity loading. Then, nonrigid intensity-based image registration is employed to recover the remaining deformation that FE analyses do not capture due to the simplifications and approximations of biomechanical models and the uncertainties of external forces and constraints. We assess the registration performance of the proposed method using the target registration error of skin fiducial markers and the Dice similarity coefficient (DSC) of fibroglandular tissues. The registration results on prone and supine MR image pairs are compared with those from two alternative nonrigid registration methods for five breasts. Overall, the proposed algorithm achieved the best registration

  20. 3D reconstruction of breast tumors from ultrasonic cross-sectional images, using fuzzy reasoning and the marching cubes algorithm

    International Nuclear Information System (INIS)

    With the intention of improving the speed and accuracy of current breast cancer screening techniques, a novel method for automatically extracting and rendering a 3D representation of a potentially cancerous tumor, from 2D ultrasonic images, has been developed. Using fuzzy reasoning and the marching cubes algorithm, the system produce an interactive 3D image of the tumor. Using measurements and characteristics of the tumour's shape, a probability of malignancy is calculated. In tests, the results produced by the system are in excellent agreement with the doctors' diagnoses. (author)

  1. Novel Multistatic Adaptive Microwave Imaging Methods for Early Breast Cancer Detection

    Science.gov (United States)

    Xie, Yao; Guo, Bin; Li, Jian; Stoica, Petre

    2006-12-01

    Multistatic adaptive microwave imaging (MAMI) methods are presented and compared for early breast cancer detection. Due to the significant contrast between the dielectric properties of normal and malignant breast tissues, developing microwave imaging techniques for early breast cancer detection has attracted much interest lately. MAMI is one of the microwave imaging modalities and employs multiple antennas that take turns to transmit ultra-wideband (UWB) pulses while all antennas are used to receive the reflected signals. MAMI can be considered as a special case of the multi-input multi-output (MIMO) radar with the multiple transmitted waveforms being either UWB pulses or zeros. Since the UWB pulses transmitted by different antennas are displaced in time, the multiple transmitted waveforms are orthogonal to each other. The challenge to microwave imaging is to improve resolution and suppress strong interferences caused by the breast skin, nipple, and so forth. The MAMI methods we investigate herein utilize the data-adaptive robust Capon beamformer (RCB) to achieve high resolution and interference suppression. We will demonstrate the effectiveness of our proposed methods for breast cancer detection via numerical examples with data simulated using the finite-difference time-domain method based on a 3D realistic breast model.

  2. Breast dosimetry

    International Nuclear Information System (INIS)

    The estimation of the absorbed dose to the breast is an important part of the quality control of the mammographic examination. Knowledge of breast dose is essential for the design and performance assessment of mammographic imaging systems. This review gives a historical introduction to the measurement of breast dose. The mean glandular dose (MGD) is introduced as an appropriate measure of breast dose. MGD can be estimated from measurements of the incident air kerma at the surface of the breast and the application of an appropriate conversion factor. Methods of calculating and measuring this conversion factor are described and the results discussed. The incident air kerma itself may be measured for patients or for a test phantom simulating the breast. In each case the dose may be determined using TLD measurements, or known exposure parameters and measurements of tube output. The methodology appropriate to each case is considered and the results from sample surveys of breast dose are presented. Finally the various national protocols for breast dosimetry are compared

  3. Digital breast tomosynthesis: computer-aided detection of clustered microcalcifications on planar projection images

    International Nuclear Information System (INIS)

    This paper describes a new approach to detect microcalcification clusters (MCs) in digital breast tomosynthesis (DBT) via its planar projection (PPJ) image. With IRB approval, two-view (cranio-caudal and mediolateral oblique views) DBTs of human subject breasts were obtained with a GE GEN2 prototype DBT system that acquires 21 projection angles spanning 60° in 3° increments. A data set of 307 volumes (154 human subjects) was divided by case into independent training (127 with MCs) and test sets (104 with MCs and 76 free of MCs). A simultaneous algebraic reconstruction technique with multiscale bilateral filtering (MSBF) regularization was used to enhance microcalcifications and suppress noise. During the MSBF regularized reconstruction, the DBT volume was separated into high frequency (HF) and low frequency components representing microcalcifications and larger structures. At the final iteration, maximum intensity projection was applied to the regularized HF volume to generate a PPJ image that contained MCs with increased contrast-to-noise ratio (CNR) and reduced search space. High CNR objects in the PPJ image were extracted and labeled as microcalcification candidates. Convolution neural network trained to recognize the image pattern of microcalcifications was used to classify the candidates into true calcifications and tissue structures and artifacts. The remaining microcalcification candidates were grouped into MCs by dynamic conditional clustering based on adaptive CNR threshold and radial distance criteria. False positive (FP) clusters were further reduced using the number of candidates in a cluster, CNR and size of microcalcification candidates. At 85% sensitivity an FP rate of 0.71 and 0.54 was achieved for view- and case-based sensitivity, respectively, compared to 2.16 and 0.85 achieved in DBT. The improvement was significant (p-value = 0.003) by JAFROC analysis. (paper)

  4. SU-E-I-09: The Impact of X-Ray Scattering On Image Noise for Dedicated Breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Yang, K [Massachusetts General Hospital, Boston, MA (United States); Gazi, P [University of California, Davis, Sacramento, CA (United States); Boone, J [UC Davis Medical Center, Sacramento, CA (United States)

    2015-06-15

    Purpose: To quantify the impact of detected x-ray scatter on image noise in flat panel based dedicated breast CT systems and to determine the optimal scanning geometry given practical trade-offs between radiation dose and scatter reduction. Methods: Four different uniform polyethylene cylinders (104, 131, 156, and 184 mm in diameter) were scanned as the phantoms on a dedicated breast CT scanner developed in our laboratory. Both stationary projection imaging and rotational cone-beam CT imaging was performed. For each acquisition type, three different x-ray beam collimations were used (12, 24, and 109 mm measured at isocenter). The aim was to quantify image noise properties (pixel variance, SNR, and image NPS) under different levels of x-ray scatter, in order to optimize the scanning geometry. For both projection images and reconstructed CT images, individual pixel variance and NPS were determined and compared. Noise measurement from the CT images were also performed with different detector binning modes and reconstruction matrix sizes. Noise propagation was also tracked throughout the intermediate steps of cone-beam CT reconstruction, including the inverse-logarithmic process, Fourier-filtering before backprojection. Results: Image noise was lower in the presence of higher scatter levels. For the 184 mm polyethylene phantom, the image noise (measured in pixel variance) was ∼30% lower with full cone-beam acquisition compared to a narrow (12 mm) fan-beam acquisition. This trend is consistent across all phantom sizes and throughout all steps of CT image reconstruction. Conclusion: From purely a noise perspective, the cone-beam geometry (i.e. the full cone-angle acquisition) produces lower image noise compared to the lower-scatter fan-beam acquisition for breast CT. While these results are relevant in homogeneous phantoms, the full impact of scatter on noise in bCT should involve contrast-to-noise-ratio measurements in heterogeneous phantoms if the goal is to optimize

  5. SU-E-I-09: The Impact of X-Ray Scattering On Image Noise for Dedicated Breast CT

    International Nuclear Information System (INIS)

    Purpose: To quantify the impact of detected x-ray scatter on image noise in flat panel based dedicated breast CT systems and to determine the optimal scanning geometry given practical trade-offs between radiation dose and scatter reduction. Methods: Four different uniform polyethylene cylinders (104, 131, 156, and 184 mm in diameter) were scanned as the phantoms on a dedicated breast CT scanner developed in our laboratory. Both stationary projection imaging and rotational cone-beam CT imaging was performed. For each acquisition type, three different x-ray beam collimations were used (12, 24, and 109 mm measured at isocenter). The aim was to quantify image noise properties (pixel variance, SNR, and image NPS) under different levels of x-ray scatter, in order to optimize the scanning geometry. For both projection images and reconstructed CT images, individual pixel variance and NPS were determined and compared. Noise measurement from the CT images were also performed with different detector binning modes and reconstruction matrix sizes. Noise propagation was also tracked throughout the intermediate steps of cone-beam CT reconstruction, including the inverse-logarithmic process, Fourier-filtering before backprojection. Results: Image noise was lower in the presence of higher scatter levels. For the 184 mm polyethylene phantom, the image noise (measured in pixel variance) was ∼30% lower with full cone-beam acquisition compared to a narrow (12 mm) fan-beam acquisition. This trend is consistent across all phantom sizes and throughout all steps of CT image reconstruction. Conclusion: From purely a noise perspective, the cone-beam geometry (i.e. the full cone-angle acquisition) produces lower image noise compared to the lower-scatter fan-beam acquisition for breast CT. While these results are relevant in homogeneous phantoms, the full impact of scatter on noise in bCT should involve contrast-to-noise-ratio measurements in heterogeneous phantoms if the goal is to optimize

  6. Targeting ferritin receptors for the selective delivery of imaging and therapeutic agents to breast cancer cells

    Science.gov (United States)

    Geninatti Crich, S.; Cadenazzi, M.; Lanzardo, S.; Conti, L.; Ruiu, R.; Alberti, D.; Cavallo, F.; Cutrin, J. C.; Aime, S.

    2015-04-01

    In this work the selective uptake of native horse spleen ferritin and apoferritin loaded with MRI contrast agents has been assessed in human breast cancer cells (MCF-7 and MDA-MB-231). The higher expression of L-ferritin receptors (SCARA5) led to an enhanced uptake in MCF-7 as shown in T2 and T1 weighted MR images, respectively. The high efficiency of ferritin internalization in MCF-7 has been exploited for the simultaneous delivery of curcumin, a natural therapeutic molecule endowed with antineoplastic and anti-inflammatory action, and the MRI contrast agent Gd-HPDO3A. This theranostic system is able to treat selectively breast cancer cells over-expressing ferritin receptors. By entrapping in apoferritin both Gd-HPDO3A and curcumin, it was possible to deliver a therapeutic dose of 167 μg ml-1 (as calculated by MRI) of this natural drug to MCF-7 cells, thus obtaining a significant reduction of cell proliferation.In this work the selective uptake of native horse spleen ferritin and apoferritin loaded with MRI contrast agents has been assessed in human breast cancer cells (MCF-7 and MDA-MB-231). The higher expression of L-ferritin receptors (SCARA5) led to an enhanced uptake in MCF-7 as shown in T2 and T1 weighted MR images, respectively. The high efficiency of ferritin internalization in MCF-7 has been exploited for the simultaneous delivery of curcumin, a natural therapeutic molecule endowed with antineoplastic and anti-inflammatory action, and the MRI contrast agent Gd-HPDO3A. This theranostic system is able to treat selectively breast cancer cells over-expressing ferritin receptors. By entrapping in apoferritin both Gd-HPDO3A and curcumin, it was possible to deliver a therapeutic dose of 167 μg ml-1 (as calculated by MRI) of this natural drug to MCF-7 cells, thus obtaining a significant reduction of cell proliferation. Electronic supplementary information (ESI) available: Competition studies with free apoferritin, Fig. S1; APO-FITC intracellular distribution by

  7. Breast vasculitis in association with breast gigantism in a pregnant patient with systemic lupus erythematosus.

    OpenAIRE

    Propper, D J; Reid, D.M.; Stankler, L.; Eastmond, C J

    1991-01-01

    A 24 year old woman with systemic lupus erythematosus (SLE) developed widespread necrotic skin ulceration and gigantism of both breasts during an exacerbation of SLE in the last trimester of her second pregnancy. Over the remainder of the pregnancy the ulceration was only controlled by high dose corticosteroids. After parturition, however, it was possible to reduce the steroid dose without recurrence of the ulceration.

  8. Risk of Needle-track Seeding After Diagnostic Image-guided Core Needle Biopsy in Breast Cancer

    OpenAIRE

    Knight, Rebecca; Horiuchi, Kent; Parker, Steve H.; Ratzer, Erick R.; Fenoglio, Michael E.

    2002-01-01

    Objective: Image-guided core needle biopsy (IGCNB) is an accepted technique for sampling nonpalpable mammographically detected suspicious breast lesions. However, the concern for needle-track seeding in malignant lesions remains. An alternative to IGCNB is needle-localization breast biopsy (NLBB). No study has been done to compare the local recurrence rate of breast cancer after IGCNB versus NLBB. Methods: We have retrospectively reviewed the local recurrence of breast cancer in patients diag...

  9. Personal digital image filing system

    International Nuclear Information System (INIS)

    The authors have developed a personal digital image filing system for archiving and displaying radiologic images. The system consists of a data link to the central storage of the picture archiving and communication system, an archiving system with a 3.5-inch optical disk drive for personal image data, and display stations for reviewing personal image files. The optical disk is analogous to the patient's film jacket

  10. Magnetic resonance imaging appearances in primary and secondary angiosarcoma of the breast.

    LENUS (Irish Health Repository)

    O'Neill, Ailbhe C

    2014-04-01

    Angiosarcomas are malignant tumours of endovascular origin. They are rare tumours accounting for 0.04-1% of all breast malignancies. Two different forms are described: primary, occurring in young women, and secondary angiosarcoma, which occurs in older women with a history of breast-conserving surgery and radiation therapy. Imaging findings on mammography and ultrasound are non-specific, but magnetic resonance imaging with dynamic contrast enhancement is more informative. We present two cases - one of primary and one of secondary angiosarcoma - and review the imaging findings.

  11. Intraindividual, randomized comparison of the macrocyclic contrast agents gadobutrol and gadoterate meglumine in breast magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fallenberg, Eva M.; Renz, Diane M.; Hamm, Bernd [Charite - Universitaetsmedizin Berlin, Campus Virchow-Klinikum, Department of Radiology, Berlin (Germany); Karle, Bettina [Clinic of Radiation Therapy, Helios Clinics, Berlin (Germany); Schwenke, Carsten [SCOSSIS Statistical Consulting, Berlin (Germany); Ingod-Heppner, Barbara [Charite Universitaetsmedizin, Campus Charite Mitte, Institute of Pathology, Berlin (Germany); Reles, Angela [Charite Universitaetsmedizin, Charite-Partner-Practice, Interdisciplinary Breast Center, Berlin (Germany); Engelken, Florian J. [Charite - Universitaetsmedizin Berlin, Charite Campus Mitte, Department of Radiology, Berlin (Germany); Huppertz, Alexander; Taupitz, Matthias [Charite - Universitaetsmedizin Berlin, Campus Benjamin Franklin, Department of Radiology, Berlin (Germany)

    2014-09-25

    To compare intraindividually two macrocyclic contrast agents - gadobutrol and gadoterate meglumine (Gd-DOTA) - for dynamic and quantitative assessment of relative enhancement (RE) in benign and malignant breast lesions. This was an ethically approved, prospective, single-centre, randomized, crossover study in 52 women with suspected breast lesions referred for magnetic resonance imaging (MRI). Each patient underwent one examination with gadobutrol and one with Gd-DOTA (0.1 mmol/kg BW) on a 1.5 T system 1 - 7 days apart. Dynamic, T1-weighted, 3D gradient echo sequences were acquired under identical conditions. Quantitative evaluation with at least three regions of interest (ROI) per lesion was performed. Primary endpoint was RE during the initial postcontrast phase after the first and second dynamic acquisition, and peak RE. All lesions were histologically proven; differences between the examinations were evaluated. Forty-five patients with a total of 11 benign and 34 malignant lesions were assessed. Mean RE was significantly higher for gadobutrol than Gd-DOTA (p < 0.0001). Gadobutrol showed significantly less washout (64.4 %) than Gd-DOTA (75.4 %) in malignant lesions (p = 0.048) Gadobutrol has higher RE values compared with Gd-DOTA, whereas Gd-DOTA shows more marked washout in malignant lesions. This might improve the detection of breast lesions and influence the specificity of breast MRI-imaging. (orig.)

  12. Clinical experiences with photoacoustic breast imaging: the appearance of suspicious lesions

    NARCIS (Netherlands)

    Heijblom, Michelle

    2014-01-01

    This thesis describes photoacoustic (PA) imaging of suspicious breast lesions. In PA imaging, the tissue of interest is illuminated by short pulses of laser light, usually in the near infrared (NIR) regime. Upon absorption by primarily the tumor vasculature, the light causes a small temperature incr

  13. Aesthetic breast augmentation with hyaluronic acid: imaging findings and implications for radiological assessment

    Directory of Open Access Journals (Sweden)

    Divanei Aparecida Bottaro Criado

    2012-06-01

    Full Text Available New injectable fillers such as hyaluronic acid have recently been employed as a non-surgical alternative to implants such as silicone for aesthetic breast enhancement. Although their utilization is not yet widespread in Brazil, radiologists should be aware of the imaging findings in this context and of the implications of the presence of this filler for the radiological evaluation in the screening for breast cancer.

  14. Aesthetic breast augmentation with hyaluronic acid: imaging findings and implications for radiological assessment

    OpenAIRE

    Divanei Aparecida Bottaro Criado; Fernanda Del Campo Braojos; Ulysses dos Santos Torres; Marcos Pontes Muniz

    2012-01-01

    New injectable fillers such as hyaluronic acid have recently been employed as a non-surgical alternative to implants such as silicone for aesthetic breast enhancement. Although their utilization is not yet widespread in Brazil, radiologists should be aware of the imaging findings in this context and of the implications of the presence of this filler for the radiological evaluation in the screening for breast cancer.

  15. A numerical study of planar elliptical antennas applied to ultrawideband (UWB) imaging of breast tissue

    OpenAIRE

    Brelum, Sindre Holsbøe

    2008-01-01

    The thesis discusses the possibility of using ultrawideband (UWB) radar to detect breast cancer. At the present time, X-ray mammography and ultrasound are the golden standard imaging techniques for detection and evaluation of breast cancer, but they both have their limitations. UWB radar utilizes the difference in dielectric properties between a tumor and the surrounding healthy tissue. By interpreting the reflected signals, it is possible to make a prediction on the localization of a tumor. ...

  16. Fluorescence Spectroscopy: An Adjunct Diagnostic Tool to Image-Guided Core Needle Biopsy of the Breast

    OpenAIRE

    Zhu, Changfang; Burnside, Elizabeth S.; Sisney, Gale A.; Salkowski, Lonie R.; Harter, Josephine M.; Yu, Bing; Ramanujam, Nirmala

    2009-01-01

    We explored the use of a fiber-optic probe for in vivo fluorescence spectroscopy of breast tissues during percutaneous image-guided breast biopsy. A total of 121 biopsy samples with accompanying histological diagnosis were obtained clinically and investigated in this study. The tissue spectra were analyzed using partial least-squares analysis and represented using a set of principal components (PCs) with dramatically reduced data dimension. For nonmalignant tissue samples, a set of PCs that a...

  17. The role of breast magnetic resonance imaging in the diagnosis of ductal carcinoma in situ

    OpenAIRE

    Nadrljanski Mirjan; Milošević Zorica; Plešinac­Karapandžić Vesna; Goldner Branislav

    2013-01-01

    Ductal carcinoma in situ (DCIS), the noninvasive breast malignant tumor originates from the terminal ductal­lobular units (TDLU). The typical feature of DCSI is the formation of calcifications. Up to 90% of DCIS are diagnosed on mammographic examinations, as clinically asymptomatic. Between 10% and 20% of DCIS remain mammographically occult due to the lack of calcifications and/ or small tumor dimensions. Contrast­enhanced breast magnetic resonance imaging (MRI) detects mammographically...

  18. Image quality control of mammography equipment -Mammography System MX-300- of the Teachers Hospital of UNSA and dose measurement in breasts with radiographic films; Control de calidad de imagen del equipo de mamografia -Mammography System MX-300- del Hospital de Docentes de la UNSA y medicion de dosis en mamas con peliculas radiograficas

    Energy Technology Data Exchange (ETDEWEB)

    Quispe F, L. K.; Vega R, J., E-mail: karinaqflores839@gmail.com [Universidad Nacional de San Agustin, Escuela Profesional de Fisica, Arequipa (Peru)

    2015-10-15

    This work is part of medical imaging for the evaluation of quality. Will have an accredited breast phantom Rmi-156 that allows evaluating the image quality of mammography equipment and through a series of techniques and processes that will submit to mammography films we obtain characteristic curves, which allows to evaluate different parameters that will serve for our study. Images were acquired with different k Vp and m As of the equipment, also with different thicknesses of the breast phantom. Also we want to use the lowest possible dose for obtaining our images. In this paper we develop a simple protocol that aims to unify the conditions under which are acquired the images for later evaluation. By obtaining these characteristic curves demonstrate that the Kodak film is the most suitable for our study because it requires lower dose for obtaining our images. (Author)

  19. Imaging oncogene expression in breast cancer with receptor specific peptides and peptide nucleic acids

    International Nuclear Information System (INIS)

    Full text: This year, breast cancer (BC) will attack approximately 210, 000 and will take the lives of 40,000 women in the U.S. Standard screening with breast self-examination and mammography, recommended to minimize BC morbidity, miss 10-20% (up to 40% in young women) of breast cancer. Moreover, if an abnormality is found, an invasive diagnostic procedure is required to determine if the breast contains hyperplasia, atypia, or cancer. Approximately 80% of invasive procedures detect a benign pathology. BC cells express a gene product, cell surface receptor VPAC1, so named because the endogenous growth hormones Vasoctive Intestinal Peptide (VIP) and Pituitary Adenylate Cylcase Activating Peptide (PACAP) bind to VPAC1 receptors with high affinity. VPAC1 receptors are overexpressed on 100% of human breast cancer cells. Cyclin D1 is a key regulator of the cell cycle and overexpressed in 50% to 80% of breast cells, whereas it is low or absent in normal breast tissues. The human breast cancer cell line MCF7 displays elevated levels of CCND1 mRNA, encoding cyclin D1, and an elevated level of IGF1R mRNA, encoding insulin-like growth factor 1 receptor. We hypothesed that 99mTc or 64Cu labeled VIP analogues, or a peptide nucleic acid (PNA) chimera specific for IGFI receptor and CCND1 mRNA, will permit us to early image breast cancer by planar, SPECT or PET imaging. We synthesized, characterized and administered i.v. 99mTc-AcGly-D (Ala)-Gly-Glyaminobutanoyl- VIP (TP3654), 64Cu diaminodithiol-aminobutanoyl-VIP (TP3982), 99mTc- AcGly-D(Ala)-Gly-Gly-PNA-D(Cys-ser-lys-Cys) chimera (WT4185) and Cu-64-DOTAPNA- D(cys-ser-lys-cys) (WT4348). A 12mer, CTGGTGTTCCAT nucleic acid sequence served as the PNA and 3 or 4 mer mismatched PNAs as negative controls. Using 99mTc-TP3654 we have successfully imaged human breast cancers not detectable by current modalities. In athymic, nude mice bearing MCF-7 human breast cancer xenographs, Cu-64-TP3982 tumour uptake was 85 times greater than 99m

  20. Clinical evaluation of fat suppressed fast-SPGR sequence of the breast MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Mitsuyuki; Hasegawa, Makoto; Matsubara, Tadashi [Yokohama Sakae Kyosai Hospital (Japan)

    1998-05-01

    MR-mammography by fat suppressed Fast-SPGR was evaluated for diagnosis and determination of invasion of tumor. Dynamic MRIs were performed in 12 phases, such as, before infusion of contrast media, right after and one to ten minutes after infusion with interval of one minute. In 15 patients (breast cancer, fibroadenoma, lymphocytic lobulitits and cystic intraductal papilloma), underwent MRI, the images were compared with pathological findings. Ten cases were confirmed as malignancy among 11 cases of breast cancer (sensitivity 91%). Eleven cases were confirmed as breast cancer among 12 cases diagnosed as breast cancer by MRI (specificity 92%). In 12 of all 15 cases, benignity or malignancy was checked correctly (accuracy 80%). Invasion of breast cancer was defined as the deep color dyeing area which was neighbored with the tumor in early stage of cystography. Eight of 11 cases were diagnosed precisely with fat suppression image, and nine were by subtraction image. Diagnosis was possible only by subtraction image in a case of scirrhous carcinoma accompanied with intradutal invasion. The area of invasion was not defined correctly in the case accompanied by mastopathy. It is difficult to evaluate benignity or malignancy of mammary gland tumor only by dynamic MRI, it is necessary to diagnose the shape and deep color image of tumor generally. (K.H.)

  1. 18F-fluoride PET imaging in a nude rat model of bone metastasis from breast cancer: Comparison with 18F-FDG and bioluminescence imaging

    International Nuclear Information System (INIS)

    Introduction: Clinically-relevant animal models and appropriate imaging diagnostic tools are essential to study cancer and develop novel therapeutics. We evaluated a model of bone metastasis in nude rats by micro-PET and bioluminescence imaging. Methods: A bone metastasis model was produced by intracardiac injection of osteotropic MDA-MB-231Bo-Luc human breast cancer cells into nude rats. Bioluminescence imaging and micro-PET scans using 18F-FDG and 18F-fluoride were acquired serially for 5 weeks. We correlated bioluminescence imaging, 18F-FDG and 18F-fluoride PET images, and histological slides. Results: Multiple bone metastases were successfully evaluated by bioluminescence imaging and 18F-FDG and 18F-fluoride PET scans. Bioluminescence photon flux increased exponentially on weekly follow-up. 18F-FDG PET revealed increased FDG uptake at the spine and bilaterally in the hind legs in week 2 images, and showed a progressive pattern up to 4 weeks that correlated with bioluminescence imaging. 18F-fluoride PET showed minimal abnormal findings in week 2 images, but it showed an irregular pattern at the spine from week 3 or 4 images. On quantitative analysis with standardized uptake values, a pattern of gradual increase was observed from week 2 to week 4 in both 18F-FDG PET and fluoride PET. Histopathological examination confirmed the formation of osteolytic metastasis and necrosis of the distal femur, which appeared as a photon defect on PET scans. Conclusion: Developing bone metastasis from breast cancer in a nude rat model was successfully evaluated with an animal PET imaging system and bioluminescence imaging. This nude rat model of bone metastasis, which can be evaluated by PET imaging, may be a valuable tool for evaluating early responses to novel therapeutics

  2. Full Intelligent Cancer Classification of Thermal Breast Images to Assist Physician in Clinical Diagnostic Applications.

    Science.gov (United States)

    Lashkari, AmirEhsan; Pak, Fatemeh; Firouzmand, Mohammad

    2016-01-01

    Breast cancer is the most common type of cancer among women. The important key to treat the breast cancer is early detection of it because according to many pathological studies more than 75% - 80% of all abnormalities are still benign at primary stages; so in recent years, many studies and extensive research done to early detection of breast cancer with higher precision and accuracy. Infra-red breast thermography is an imaging technique based on recording temperature distribution patterns of breast tissue. Compared with breast mammography technique, thermography is more suitable technique because it is noninvasive, non-contact, passive and free ionizing radiation. In this paper, a full automatic high accuracy technique for classification of suspicious areas in thermogram images with the aim of assisting physicians in early detection of breast cancer has been presented. Proposed algorithm consists of four main steps: pre-processing & segmentation, feature extraction, feature selection and classification. At the first step, using full automatic operation, region of interest (ROI) determined and the quality of image improved. Using thresholding and edge detection techniques, both right and left breasts separated from each other. Then relative suspected areas become segmented and image matrix normalized due to the uniqueness of each person's body temperature. At feature extraction stage, 23 features, including statistical, morphological, frequency domain, histogram and Gray Level Co-occurrence Matrix (GLCM) based features are extracted from segmented right and left breast obtained from step 1. To achieve the best features, feature selection methods such as minimum Redundancy and Maximum Relevance (mRMR), Sequential Forward Selection (SFS), Sequential Backward Selection (SBS), Sequential Floating Forward Selection (SFFS), Sequential Floating Backward Selection (SFBS) and Genetic Algorithm (GA) have been used at step 3. Finally to classify and TH labeling procedures

  3. Imaging Features of AlloDerm® Used in Postmastectomy Breast Reconstructions

    Directory of Open Access Journals (Sweden)

    Christine U Lee

    2014-01-01

    Full Text Available The purpose of this pictorial essay is to demonstrate the imaging features (ultrasound, mammogram, and magnetic resonance imaging (MRI of AlloDerm® (LifeCell Corp.; Branchburg, NJ, an acellular dermal matrix sometimes used in both primary and reconstructive breast surgeries. AlloDerm® is derived from cadaveric dermis and provides an immunologically inert scaffold in tissue reconstruction. Since there is little literature on the imaging of this substance, radiologists may be unfamiliar with its appearance in breast imaging. For this manuscript, ex vivo and in vivo images of AlloDerm® in postmastectomy patients were evaluated using different imaging modalities. The appearance of AlloDerm® can vary based on length of time postsurgery and incorporation into the host. AlloDerm® appears as an isodense to glandular tissue on a mammogram and isoechoic to glandular tissue on ultrasound imaging. On MRI, in comparison with normal breast parenchyma, AlloDerm® is hyperintense on T2-weighted imaging and isointense on T1-weighted imaging and demonstrates mild enhancement. To the best of the authors′ knowledge, this is the first multimodality imaging description of AlloDerm® used in postmastectomy patients. The conformation of AlloDerm® at surgical placement and the degree of host cell migration and neoangiogenesis are factors to take into consideration when performing diagnostic evaluations; and, familiarity with the various imaging appearances of AlloDerm® can be helpful to exclude residual or recurrent disease.

  4. Feeling like me again: a grounded theory of the role of breast reconstruction surgery in self-image.

    Science.gov (United States)

    McKean, L N; Newman, E F; Adair, P

    2013-07-01

    The present study aimed to develop a theoretical understanding of the role of breast reconstruction in women's self-image. Semi-structured interviews were conducted with 10 women from breast cancer support groups who had undergone breast reconstruction surgery. A grounded theory methodology was used to explore their experiences. The study generated a model of 'breast cancer, breast reconstruction and self-image', with a core category entitled 'feeling like me again' and two principal categories of 'normal appearance' and 'normal life'. A further two main categories, 'moving on' and 'image of sick person' were generated. The results indicated a role of breast reconstruction in several aspects of self-image including the restoration of pre-surgery persona, which further promoted adjustment. PMID:23730890

  5. Image guided Brachytherapy: The paradigm of Gynecologic and Partial Breast HDR Brachytherapy

    Science.gov (United States)

    Diamantopoulos, S.; Kantemiris, I.; Konidari, A.; Zaverdinos, P.

    2015-09-01

    High dose rate (HDR) brachytherapy uses high strength radioactive sources and temporary interstitial implants to conform the dose to target and minimize the treatment time. The advances of imaging technology enable accurate reconstruction of the implant and exact delineation of high-risk CTV and the surrounding critical structures. Furthermore, with sophisticated treatment planning systems, applicator devices and stepping source afterloaders, brachytherapy evolved to a more precise, safe and individualized treatment. At the Radiation Oncology Department of Metropolitan Hospital Athens, MRI guided HDR gynecologic (GYN) brachytherapy and accelerated partial breast irradiation (APBI) with brachytherapy are performed routinely. Contouring and treatment planning are based on the recommendations of the GEC - ESTRO Working group. The task of this presentation is to reveal the advantages of 3D image guided brachytherapy over 2D brachytherapy. Thus, two patients treated at our department (one GYN and one APBI) will be presented. The advantage of having adequate dose coverage of the high risk CTV and simultaneous low doses to the OARs when using 3D image- based brachytherapy will be presented. The treatment techniques, equipment issues, as well as implantation, imaging and treatment planning procedures will be described. Quality assurance checks will be treated separately.

  6. Normal breast tissue stiffness measured by a new ultrasound technique: Virtual touch tissue imaging quantification (VTIQ)

    Energy Technology Data Exchange (ETDEWEB)

    Golatta, Michael, E-mail: Michael.Golatta@med.uni-heidelberg.de [Breast Unit, University of Heidelberg, Im Neuenheimer Feld 440, D-69120 Heidelberg (Germany); Schweitzer-Martin, Mirjam; Harcos, Aba; Schott, Sarah; Junkermann, Hans [Breast Unit, University of Heidelberg, Im Neuenheimer Feld 440, D-69120 Heidelberg (Germany); Rauch, Geraldine [Institute of Medical Biometry and Informatics, University of Heidelberg, Heidelberg (Germany); Sohn, Christof; Heil, Jörg [Breast Unit, University of Heidelberg, Im Neuenheimer Feld 440, D-69120 Heidelberg (Germany)

    2013-11-01

    Objective: To evaluate normal breast tissue stiffness with virtual touch tissue imaging quantification (VTIQ) using prospectively collected data. Materials and Methods: B-mode ultrasound and VTIQ were performed in 132 breasts in 97 women. Mean values of VTIQ for parenchyma and fatty tissue were compared between those measured in healthy breasts and in the surrounding of histologically proven benign and malignant breast lesions. Moreover we reviewed VTIQ values according to breast density measured by the American College of Radiology (ACR) categories. In addition we analyzed re-test reliability of VTIQ. Results: In 132 breasts the mean VTIQ values in parenchyma were significantly higher than in fatty tissue (3.23 m/s ± 0.74 versus 2.5 m/s ± 0.61; p < 0.0001). In healthy breasts as well as in the surrounding of a benign or malignant lesions the VTIQ values of parenchyma were similar (p = 0.12). In fatty tissue, small differences between mean VTIQ values of 2.25 m/s ± 0.51, 2.52 m/s ± 0.48 and 2.65 m/s ± 0.71 (p = 0.01) in the respective groups were observed. The comparison of mean VTIQ values of parenchyma and fatty tissue in more and less dense breasts (ACR 1 + 2 versus ACR 3 + 4 breasts) also yielded no statistically significant difference. The re-test reliability of VTIQ assessed with three independent measurements was moderate (interclass-correlation of 0.52 (p < 0.0001)). Conclusion: VTIQ is a reliable method for measuring the stiffness of breast tissue. We propose standard values for healthy parenchyma and fatty tissues independent of the surrounding tissue or the ACR category.

  7. Normal breast tissue stiffness measured by a new ultrasound technique: Virtual touch tissue imaging quantification (VTIQ)

    International Nuclear Information System (INIS)

    Objective: To evaluate normal breast tissue stiffness with virtual touch tissue imaging quantification (VTIQ) using prospectively collected data. Materials and Methods: B-mode ultrasound and VTIQ were performed in 132 breasts in 97 women. Mean values of VTIQ for parenchyma and fatty tissue were compared between those measured in healthy breasts and in the surrounding of histologically proven benign and malignant breast lesions. Moreover we reviewed VTIQ values according to breast density measured by the American College of Radiology (ACR) categories. In addition we analyzed re-test reliability of VTIQ. Results: In 132 breasts the mean VTIQ values in parenchyma were significantly higher than in fatty tissue (3.23 m/s ± 0.74 versus 2.5 m/s ± 0.61; p < 0.0001). In healthy breasts as well as in the surrounding of a benign or malignant lesions the VTIQ values of parenchyma were similar (p = 0.12). In fatty tissue, small differences between mean VTIQ values of 2.25 m/s ± 0.51, 2.52 m/s ± 0.48 and 2.65 m/s ± 0.71 (p = 0.01) in the respective groups were observed. The comparison of mean VTIQ values of parenchyma and fatty tissue in more and less dense breasts (ACR 1 + 2 versus ACR 3 + 4 breasts) also yielded no statistically significant difference. The re-test reliability of VTIQ assessed with three independent measurements was moderate (interclass-correlation of 0.52 (p < 0.0001)). Conclusion: VTIQ is a reliable method for measuring the stiffness of breast tissue. We propose standard values for healthy parenchyma and fatty tissues independent of the surrounding tissue or the ACR category

  8. Nonlinear 3-D Microwave Imaging for Breast-Cancer Screening: Log, Phase, and Log-Phase Formulation

    DEFF Research Database (Denmark)

    Jensen, Peter Damsgaard; Rubæk, Tonny; Mohr, Johan Jacob;

    2011-01-01

    The imaging algorithm used in the 3-D microwave imaging system for breast cancer screening, currently being developed at the Technical University of Denmark, is based on an iterative Newton-type algorithm. In this algorithm, the distribution of the electromagnetic constitutive parameters is updated...... their amplitudes and their unwrapped phases. In this paper, simplifications of the log-phase formulation are proposed, namely the log formulation, in which only the logarithm of the amplitudes are used, and the phase formulation, in which only the unwrapped phases are used. These formulations allow for...

  9. Imaging screening of breast cancer: primary results in 5307 cases

    International Nuclear Information System (INIS)

    Objective: To discuss the values of three screening methods for the detection of early breast cancer, and to analyze the features of the screening cancer. Methods: The first screening of breast cancer were performed in 5307 women who aged from 20 to 76 years with median age of 49 years. The three screening methods included physical examination with ultrasound and mammography, physical examination with mammography and mammography only. The rate of recall, biopsy, cancer detection of three methods were analyzed and the mammographic findings were reviewed. Chi-square test or Fisher's exact test were used for the statistics. Results: The recall rates were 4.90% (49/1001), 6.90% (166/2407) and 4. 48% (85/1899) in three methods respectively, the biopsy rates were 1.60% (16/1001), 1.04% (25/2407) and 0.63% (12/1899), the cancer detection rates were 0.50% (5/1001), 0.17% (4/2407) and 0 (0/1899). There were statistical differences among the three groups (χ2=12.99,6.264,8.764, P<0.05). Physical examination with ultrasound and mammography had the highest cancer detection rate, ten breast cancers were detected and 8 were early stage breast cancer. Of seven cancers detected by mammography, only two were found by ultrasound. A cluster of calcifications were found in 2 cases, linear calcifications in 2 cases. One case presented as a asymmetric density, one as a asymmetric density with calcifications, one as multiple nodules with a cluster of calcifications. Two breast cancers presented as asymmetric density were missed on mammography and diagnosed correctly after retrospective review. Conclusion: Physical examination with ultrasound and mammography is the best method for breast cancer screening. The breast cancer can be detected by mammography earlier than other methods. (authors)

  10. Bromine-77-labeled estrogen receptor-binding radiopharmaceuticals for breast tumor imaging

    International Nuclear Information System (INIS)

    Two derivatives of 16α-bromoestradiol, both with and without an 11β-methoxy substituent, have been labeled with bromine-77 and evaluated as potential breast tumor imaging agents. Extensive characterization of these radiotracers in animal models has demonstrated their effective concentration in estrogen target tissues. Preliminary clinical studies have demonstrated the potential of radiolabeled estrogens for breast tumor imaging; however, the suboptimal decay properties of bromine-77 limit the utility of these agents in imaging studies. These results with 77-Br-labeled estrogens suggest that estrogen derivatives labeled with other radionuclides should provide enhanced image resolution with various imaging devices. Although the decay characteristics of bromine-77 are such that it is not ideally suited to imaging with conventional gamma cameras, it may be a useful radionuclide for therapeutic applications

  11. Free-form deformation based non-rigid registration on breast cancer MR imaging

    Science.gov (United States)

    Zhang, Liangbin; Suo, Shiteng; Lu, Xuesong; Li, Yuehua; Chen, Li; Zhang, Su

    2013-07-01

    High-Intensity Focused Ultrasound treatment combined with magnetic resonance technology (MRI-guided HIFU, MRgHIFU) can protect the thermal ablation without harming the surrounding tissue by using MRI for target positioning, where image registration plays an important role in the implementation of precise treatment. In this paper, we apply three-dimension free-form deformation non-rigid registration on treatment plan amendments and tracking of breast cancer. Free-form deformation based and demons based non-rigid registration are respectively employed on breast cancer MR imaging required at different times before and after for comparison. The results of the experiments show that the registration performed on the breast tumor image data with slight and larger deformation is effective, and the mutual information of the ROI increased from 1.49 before registration to 1.53.

  12. Investigation of near infrared autofluorescence imaging for the detection of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Demos, S G; Bold, R; White, R d; Ramsamooj, R

    2005-08-19

    Detection of breast cancer in fresh tissue obtained from surgery is investigated using Near-infrared autofluorescence imaging under laser excitation at 532-nm and 632.8-nm. The differences in intensity between the three main components of breast tissue (cancer, fibrous and adipose) are estimated and compared to those obtained from cross-polarized light scattering images recorded under polarized illumination at 700-nm. The optical spectroscopic images for each tissue sample were subsequently compared with the histopathology slides. The experimental results indicate that the intensity of the near-infrared emission is considerably different in breast cancer compared to that of the adjacent non-neoplastic tissues (adipose and fibrous tissue). The experimental results suggest that 632.8-nm excitation offers key advantages compared to 532-nm excitation.

  13. Magnetic resonance imaging in size assessment of invasive breast carcinoma with an extensive intraductal component

    Directory of Open Access Journals (Sweden)

    Bult Peter

    2009-04-01

    Full Text Available Abstract Background Breast-conserving treatment of invasive breast carcinoma with an extensive intraductal component (EIC is associated with DCIS-involved surgical margins and therefore it has an increased recurrence rate. EIC is a non-palpable lesion of which the size is frequently underestimated on mammography. This study was undertaken to evaluate the accuracy of MRI in size assessment of breast cancer with EIC. Methods 23 patients were identified and the mammographic (n = 21 and MR (n = 23 images were re-reviewed by a senior radiologist. Size on MR images was compared with histopathological tumour extent. Results The correlation of radiological size with histopathological size was r = 0.20 in mammography (p = 0.39 compared to r = 0.65 in MRI (p Conclusion Size assessment of MRI imaging was more accurate compared to mammography. This was predominantly true for poorly differentiated EIC.

  14. EDITORIAL: Optical mammography: Imaging and characterization of breast lesions by pulsed near-infrared laser light (OPTIMAMM)

    Science.gov (United States)

    Hebden, Jeremy C.; Rinneberg, Herbert

    2005-06-01

    mortality associated with it, within the EU and throughout the world. Although x-ray mammography is recognized as an effective tool for cancer screening in women over 35-40 years of age, it suffers from a significant number of false positives which often lead to unnecessary biopsy. X-ray mammography is also less effective for younger women with denser breasts, and involves the use of potentially harmful ionizing radiation. While other conventional diagnostic techniques such as ultrasound and magnetic resonance imaging (MRI) are also widely used in the diagnosis and characterization of breast disease, their roles in the detection and staging of breast tumours have so far been limited. The development of optical methods of imaging the breast is attractive partly because they are safe, but chiefly because they can reveal contrast between normal and diseased tissues which are not evident using conventional methods. The principal mechanism for contrast at near-infrared wavelengths is the characteristic absorption by haemoglobin and other dominant tissue chromophores, such as fat and water. Furthermore, the differences between the absorption of oxy-haemoglobin and deoxy-hemoglobin provide a means of determining oxygenation, and therefore of studying tissue function. The OPTIMAMM project focused specifically on the diagnostic potential of time-resolved methods. Systems which measure the flight-times of photons transmitted across highly scattering breast tissue offer the potential to provide greater spatial resolution and contrast than systems based on intensity measurements alone, and facilitate better separation between the effects of scatter and those of absorption. A major component of the project was a series of clinical trials performed at four European sites, in particular in Berlin (Germany) and Milan (Italy) using similar scanning instrumentation, carried out under a harmonized clinical protocol where appropriate. The clinical trials were augmented by efforts to refine

  15. MO-A-BRD-01: An Investigation of the Dynamic Response of a Novel Acousto-Optic Liquid Crystal Detector for Full-Field Transmission Ultrasound Breast Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Rosenfield, J.R.; La Riviere, P.J. [The University of Chicago, Department of Radiology (United States); Sandhu, J.S. [Santec Systems Inc., Arlington Heights, IL (United States)

    2014-06-15

    Purpose: To characterize the dynamic response of a novel acousto-optic (AO) liquid crystal detector for high-resolution transmission ultrasound breast imaging. Transient and steady-state lesion contrast were investigated to identify optimal transducer settings for our prototype imaging system consistent with the FDA limits of 1 W/cm{sup 2} and 50 J/cm{sup 2} on the incident acoustic intensity and the transmitted acoustic energy flux density. Methods: We have developed a full-field transmission ultrasound breast imaging system that uses monochromatic plane-wave illumination to acquire projection images of the compressed breast. The acoustic intensity transmitted through the breast is converted into a visual image by a proprietary liquid crystal detector operating on the basis of the AO effect. The dynamic response of the AO detector in the absence of an imaged breast was recorded by a CCD camera as a function of the acoustic field intensity and the detector exposure time. Additionally, a stereotactic needle biopsy breast phantom was used to investigate the change in opaque lesion contrast with increasing exposure time for a range of incident acoustic field intensities. Results: Using transducer voltages between 0.3 V and 0.8 V and exposure times of 3 minutes, a unique one-to-one mapping of incident acoustic intensity to steady-state optical brightness in the AO detector was observed. A transfer curve mapping acoustic intensity to steady-state optical brightness shows a high-contrast region analogous to the linear portion of the Hurter-Driffield curves of radiography. Using transducer voltages between 1 V and 1.75 V and exposure times of 90 s, the lesion contrast study demonstrated increasing lesion contrast with increasing breast exposure time and acoustic field intensity. Lesion-to-background contrast on the order of 0.80 was observed. Conclusion: Maximal lesion contrast in our prototype system can be obtained using the highest acoustic field intensity and the

  16. MO-A-BRD-01: An Investigation of the Dynamic Response of a Novel Acousto-Optic Liquid Crystal Detector for Full-Field Transmission Ultrasound Breast Imaging

    International Nuclear Information System (INIS)

    Purpose: To characterize the dynamic response of a novel acousto-optic (AO) liquid crystal detector for high-resolution transmission ultrasound breast imaging. Transient and steady-state lesion contrast were investigated to identify optimal transducer settings for our prototype imaging system consistent with the FDA limits of 1 W/cm2 and 50 J/cm2 on the incident acoustic intensity and the transmitted acoustic energy flux density. Methods: We have developed a full-field transmission ultrasound breast imaging system that uses monochromatic plane-wave illumination to acquire projection images of the compressed breast. The acoustic intensity transmitted through the breast is converted into a visual image by a proprietary liquid crystal detector operating on the basis of the AO effect. The dynamic response of the AO detector in the absence of an imaged breast was recorded by a CCD camera as a function of the acoustic field intensity and the detector exposure time. Additionally, a stereotactic needle biopsy breast phantom was used to investigate the change in opaque lesion contrast with increasing exposure time for a range of incident acoustic field intensities. Results: Using transducer voltages between 0.3 V and 0.8 V and exposure times of 3 minutes, a unique one-to-one mapping of incident acoustic intensity to steady-state optical brightness in the AO detector was observed. A transfer curve mapping acoustic intensity to steady-state optical brightness shows a high-contrast region analogous to the linear portion of the Hurter-Driffield curves of radiography. Using transducer voltages between 1 V and 1.75 V and exposure times of 90 s, the lesion contrast study demonstrated increasing lesion contrast with increasing breast exposure time and acoustic field intensity. Lesion-to-background contrast on the order of 0.80 was observed. Conclusion: Maximal lesion contrast in our prototype system can be obtained using the highest acoustic field intensity and the longest breast

  17. 3D electron density imaging using single scattered x rays with application to breast CT and mammographic screening

    Science.gov (United States)

    van Uytven, Eric Peter

    Screening mammography is the current standard in detecting breast cancer. However, its fundamental disadvantage is that it projects a 3D object into a 2D image. Small lesions are difficult to detect when superimposed over layers of normal tissue. Commercial Computed Tomography (CT) produces a true 3D image yet has a limited role in mammography due to relatively low resolution and contrast. With the intent of enhancing mammography and breast CT, we have developed an algorithm which can produce 3D electron density images using a single projection. Imaging an object with x rays produces a characteristic scattered photon spectrum at the detector plane. A known incident beam spectrum, beam shape, and arbitrary 3D matrix of electron density values enable a theoretical scattered photon distribution to be calculated. An iterative minimization algorithm is used to make changes to the electron density voxel matrix to reduce regular differences between the theoretical and the experimentally measured distributions. The object is characterized by the converged electron density image. This technique has been validated in simulation using data produced by the EGSnrc Monte Carlo code system. At both mammographic and CT energies, a scanning polychromatic pencil beam was used to image breast tissue phantoms containing lesion-like inhomogeneities. The resulting Monte Carlo data is processed using a Nelder-Mead iterative algorithm (MATLAB) to produce the 3D matrix of electron density values. Resulting images have confirmed the ability of the algorithm to detect various 1x1x2.5 mm3 lesions with calcification content as low as 0.5% (p<0.005) at a dose comparable to mammography.

  18. Validation of mean glandular dose values provided by a digital breast tomosynthesis system in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Beraldo O, B.; Paixao, L.; Donato da S, S. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Post-graduation in Sciences and Technology of Radiations Minerals and Materials, Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte (Brazil); Araujo T, M. H. [Dr Maria Helena Araujo Teixeira Clinic, Guajajaras 40, 30180-100 Belo Horizonte (Brazil); Nogueira, M. S., E-mail: bbo@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte (Brazil)

    2014-08-15

    Digital breast tomosynthesis (DBT) is an emerging imaging modality that provides quasi-three-dimensional structural information of the breast and has strong promise to improve the differentiation of normal tissue and suspicious masses reducing the tissue overlaps. DBT images are reconstructed from a sequence of low-dose X-ray projections of the breast acquired at a small number of angles over a limited angular range. The Ho logic Selen ia Dimensions system is equipped with an amorphous Selenium (a-Se) detector layer of 250 μm thickness and a 70 μm pixel pitch. Studies are needed to determine the radiation dose of patients that are undergoing this emerging procedure to compare with the results obtained in DBT images. The mean glandular dose (D{sub G}) is the dosimetric quantity used in quality control of the mammographic systems. The aim of this work is to validate D{sub G} values for different breast thicknesses provided by a Ho logic Selen ia Dimensions system using a DBT mode in comparison with the same results obtained by a calibrated 90 X 5-6M-model Radcal ionization chamber. D{sub G} values were derived from the incident air kerma (K{sub i}) measurements and tabulated conversion coefficients that are dependent on the half value layer (HVL) of the X-ray spectrum. Voltage and tube loading values were recorded in irradiations using W/Al anode/filter combination, automatic exposure control mode and polymethyl methacrylate (PMMA) slabs which simulate different breast thicknesses. For K{sub i} measurements, the ionization chamber was positioned at 655 mm from the focus and the same radiographic technique values were selected with the manual mode. D{sub G} values for a complete procedure ranged from 0.9 ± 0.1 to 3.7 ± 0.4 mGy. The results for different breast thicknesses are in accordance with values obtained by DBT images and with acceptable levels established by the Commission of the European Communities (Cec) and the International Atomic Energy Agency (IAEA

  19. Folate Receptor-Beta Has Limited Value for Fluorescent Imaging in Ovarian, Breast and Colorectal Cancer.

    Directory of Open Access Journals (Sweden)

    Esther de Boer

    Full Text Available Tumor-specific targeted imaging is rapidly evolving in cancer diagnosis. The folate receptor alpha (FR-α has already been identified as a suitable target for cancer therapy and imaging. FR-α is present on ~40% of human cancers. FR-β is known to be expressed on several hematologic malignancies and on activated macrophages, but little is known about FR-β expression in solid tumors. Additional or simultaneous expression of FR-β could help extend the indications for folate-based drugs and imaging agents. In this study, the expression pattern of FR-β is evaluated in ovarian, breast and colorectal cancer.FR-β expression was analyzed by semi-quantitative scoring of immunohistochemical staining on tissue microarrays (TMAs of 339 ovarian cancer patients, 418 breast cancer patients, on 20 slides of colorectal cancer samples and on 25 samples of diverticulitis.FR-β expression was seen in 21% of ovarian cancer samples, 9% of breast cancer samples, and 55% of colorectal cancer samples. Expression was weak or moderate. Of the diverticulitis samples, 80% were positive for FR-β expression in macrophages. FR-β status neither correlated to known disease-related variables, nor showed association with overall survival and progression free survival in ovarian and breast cancer. In breast cancer, negative axillary status was significantly correlated to FR-β expression (p=0.022.FR-β expression was low or absent in the majority of ovarian, breast and colorectal tumor samples. From the present study we conclude that the low FR-β expression in ovarian and breast tumor tissue indicates limited practical use of this receptor in diagnostic imaging and therapeutic purposes. Due to weak expression, FR-β is not regarded as a suitable target in colorectal cancer.

  20. Multitier image streaming teleradiology system

    Science.gov (United States)

    Swarnakar, Vivek; Eldar, Adi; Pourfathi, Shahrzad; Keselbrener, Laurence; Genant, Harry K.

    2001-08-01

    With the advent of real-time image streaming, a new paradigm for development of image display and viewing systems that communicate with Picture Archiving and Communication (PACS) systems can be proposed. In this paradigm, the high bandwidth requirements of current systems can be significantly relaxed and security features can be seamlessly adopted and enforced. Based upon this paradigm RealTimeImage and OARG have developed a multi-tiered web-based image display and analysis system for teleradiology. The system architecture consisted of a backend module to communicate with the PACS system via direct file system access or standard DICOM protocols, an Image Server to stream image data to its clients using RealTimeImage Pixel-On-DemandTM streaming technology and a web-based client to provide image display and analysis functionality. The system was used in a clinical research study that required analysis of several hundred images and included participants located at various remote geographical locations. Performance and maintainability of the system were objectively quantified. Usability issues were subjectively identified by the various users of the system. It was observed that the performance of such a system is comparable to that of today's systems over fast LAN, even if the user is connected via standard, dial-up connections. This level of performance was achieved without compromising the usability of the system required for the research study.

  1. 3-T breast magnetic resonance imaging in patients with suspicious microcalcifications on mammography

    Energy Technology Data Exchange (ETDEWEB)

    Stehouwer, B.L.; Merckel, L.G.; Verkooijen, H.M.; Peters, N.H.G.M.; Mali, W.P.T.M.; Veldhuis, W.B.; Bosch, M.A.A.J. van den [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Mann, R.M. [University Medical Center St Radboud, Departement of Radiology, Nijmegen (Netherlands); Duvivier, K.M. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); VU University Medical Center, Department of Radiology, Amsterdam (Netherlands); Peeters, P.H.M. [University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands)

    2014-03-15

    To investigate the diagnostic value of 3-Tesla (T) breast MRI in patients presenting with microcalcifications on mammography. Between January 2006 and May 2009, 123 patients with mammographically detected BI-RADS 3-5 microcalcifications underwent 3-T breast MRI before undergoing breast biopsy. All MRIs of the histopathologically confirmed index lesions were reviewed by two breast radiologists. The detection rate of invasive carcinoma and ductal carcinoma in situ (DCIS) was evaluated, as well as the added diagnostic value of MRI over mammography and breast ultrasound. At pathology, 40/123 (33 %) lesions proved malignant; 28 (70 %) DCIS and 12 (30 %) invasive carcinoma. Both observers detected all invasive malignancies at MRI, as well as 79 % (observer 1) and 86 % (observer 2) of in situ lesions. MRI in addition to conventional imaging led to a significant increase in area under the receiver operating characteristic (ROC) curve from 0.67 (95 % CI 0.56-0.79) to 0.79 (95 % CI 0.70-0.88, observer 1) and to 0.80 (95 % CI 0.71-0.89, observer 2), respectively. 3-T breast MRI was shown to add significant value to conventional imaging in patients presenting with suspicious microcalcifications on mammography. (orig.)

  2. Association between dynamic features of breast DCE-MR imaging and clinical response of neoadjuvant chemotherapy: a preliminary analysis

    Science.gov (United States)

    Huang, Lijuan; Fan, Ming; Li, Lihua; Zhang, Juan; Shao, Guoliang; Zheng, Bin

    2016-03-01

    Neoadjuvant chemotherapy (NACT) is being used increasingly in the management of patients with breast cancer for systemically reducing the size of primary tumor before surgery in order to improve survival. The clinical response of patients to NACT is correlated with reduced or abolished of their primary tumor, which is important for treatment in the next stage. Recently, the dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is used for evaluation of the response of patients to NACT. To measure this correlation, we extracted the dynamic features from the DCE- MRI and performed association analysis between these features and the clinical response to NACT. In this study, 59 patients are screened before NATC, of which 47 are complete or partial response, and 12 are no response. We segmented the breast areas depicted on each MR image by a computer-aided diagnosis (CAD) scheme, registered images acquired from the sequential MR image scan series, and calculated eighteen features extracted from DCE-MRI. We performed SVM with the 18 features for classification between patients of response and no response. Furthermore, 6 of the 18 features are selected to refine the classification by using Genetic Algorithm. The accuracy, sensitivity and specificity are 87%, 95.74% and 50%, respectively. The calculated area under a receiver operating characteristic (ROC) curve is 0.79+/-0.04. This study indicates that the features of DCE-MRI of breast cancer are associated with the response of NACT. Therefore, our method could be helpful for evaluation of NACT in treatment of breast cancer.

  3. Low Rates of Additional Cancer Detection by Magnetic Resonance Imaging in Newly Diagnosed Breast Cancer Patients Who Undergo Preoperative Mammography and Ultrasonography

    OpenAIRE

    Kim, Jisun; Han, Wonshik; Moon, Hyeong-Gon; Ahn, Soo Kyung; Shin, Hee-Chul; You, Jee-Man; Chang, Jung Min; Cho, Nariya; Moon, Woo Kyung; Park, In-Ae; Noh, Dong-Young

    2014-01-01

    Purpose We evaluated the efficacy of breast magnetic resonance imaging (MRI) for detecting additional malignancies in breast cancer patients newly diagnosed by breast ultrasonography and mammography. Methods We retrospectively reviewed the records of 1,038 breast cancer patients who underwent preoperative mammography, bilateral breast ultrasonography, and subsequent breast MRI between August 2007 and December 2010 at single institution in Korea. MRI-detected additional lesions were defined as...

  4. Robust Automatic Breast Cancer Staging Using A Combination of Functional Genomics and Image-Omics

    Science.gov (United States)

    Su, Hai; Shen, Yong; Xing, Fuyong; Qi, Xin; Hirshfield, Kim M.; Yang, Lin; Foran, David J.

    2016-01-01

    Breast cancer is one of the leading cancers worldwide. Precision medicine is a new trend that systematically examines molecular and functional genomic information within each patient's cancer to identify the patterns that may affect treatment decisions and potential outcomes. As a part of precision medicine, computer-aided diagnosis enables joint analysis of functional genomic information and image from pathological images. In this paper we propose an integrated framework for breast cancer staging using image-omics and functional genomic information. The entire biomedical imaging informatics framework consists of image-omics extraction, feature combination, and classification. First, a robust automatic nuclei detection and segmentation is presented to identify tumor regions, delineate nuclei boundaries and calculate a set of image-based morphological features; next, the low dimensional image-omics is obtained through principal component analysis and is concatenated with the functional genomic features identified by a linear model. A support vector machine for differentiating stage I breast cancer from other stages are learned. We experimentally demonstrate that compared with a single type of representation (image-omics), the combination of image-omics and functional genomic feature can improve the classification accuracy by 3%. PMID:26737959

  5. MR imaging of mucinous carcinoma of the breast associated with ductal carcinoma in situ: case report

    International Nuclear Information System (INIS)

    A mucinous carcinoma of the breast is an uncommon carcinoma containing mucin that is associated with a mucocele-like tumor or other malignant tumors. We report the MR imaging findings of two cases, a mucinous carcinoma and ductal carcinoma in situ (DCIS), associated with mucocele-like tumor. The mucinous carcinoma showed a gradually enhancing kinetic pattern on the dynamic MR and high signal intensity on the T2-weighted images. The MR findings were indistinguishable from a common benign mass of the breast

  6. Non-invasive estimation of the metabolic heat production of breast tumors using digital infrared imaging

    CERN Document Server

    González, Francisco Javier

    2011-01-01

    In this work the metabolic heat generated by breast tumors was estimated indirectly and noninvasively from digital infrared images and numerically simulating a simplified breast model and a cancerous tumor, this parameter can be of clinical importance since it has been related to the doubling volume's time and malignancy for that particular tumor. The results indicate that digital infrared imaging has the potential to estimate in a non-invasive way the malignancy of a tumor by calculating its metabolic heat generation from bioheat thermal transfer models.

  7. Medical image segmentation to estimate HER2 gene status in breast cancer

    Science.gov (United States)

    Palacios-Navarro, Guillermo; Acirón-Pomar, José Manuel; Vilchez-Sorribas, Enrique; Zambrano, Eddie Galarza

    2016-02-01

    This work deals with the estimation of HER2 Gene status in breast tumour images treated with in situ hybridization techniques (ISH). We propose a simple algorithm to obtain the amplification factor of HER2 gene. The obtained results are very close to those obtained by specialists in a manual way. The developed algorithm is based on colour image segmentation and has been included in a software application tool for breast tumour analysis. The developed tool focus on the estimation of the seriousness of tumours, facilitating the work of pathologists and contributing to a better diagnosis.

  8. The thioredoxin system in breast cancer cell invasion and migration.

    Science.gov (United States)

    Bhatia, Maneet; McGrath, Kelly L; Di Trapani, Giovanna; Charoentong, Pornpimol; Shah, Fenil; King, Mallory M; Clarke, Frank M; Tonissen, Kathryn F

    2016-08-01

    Metastasis is the most life threatening aspect of breast cancer. It is a multi-step process involving invasion and migration of primary tumor cells with a subsequent colonization of these cells at a secondary location. The aim of the present study was to investigate the role of thioredoxin (Trx1) in the invasion and migration of breast cancer cells and to assess the strength of the association between high levels of Trx1 and thioredoxin reductase (TrxR1) expression with breast cancer patient survival. Our results indicate that the expression of both Trx1 and TrxR1 are statistically significantly increased in breast cancer patient cells compared with paired normal breast tissue from the same patient. Over-expression of Trx1 in MDA-MB-231 breast cancer cell lines enhanced cell invasion in in vitro assays while expression of a redox inactive mutant form of Trx1 (designated 1SS) or the antisense mRNA inhibited cell invasion. Addition of exogenous Trx1 also enhanced cell invasion, while addition of a specific monoclonal antibody that inhibits Trx1 redox function decreased cell invasion. Over-expression of intracellular Trx1 did not increase cell migration but expression of intracellular 1SS inhibited migration. Addition of exogenous Trx1 enhanced cell migration while 1SS had no effect. Treatment with auranofin inhibited TrxR activity, cell migration and clonogenic activity of MDA-MB-231 cells, while increasing reactive oxygen species (ROS) levels. Analysis of 25 independent cohorts with 5910 patients showed that Trx1 and TrxR1 were both associated with a poor patient prognosis in terms of overall survival, distant metastasis free survival and disease free survival. Therefore, targeting the Trx system with auranofin or other specific inhibitors may provide improved breast cancer patient outcomes through inhibition of cancer invasion and migration. PMID:26760912

  9. The thioredoxin system in breast cancer cell invasion and migration

    Directory of Open Access Journals (Sweden)

    Maneet Bhatia

    2016-08-01

    Full Text Available Metastasis is the most life threatening aspect of breast cancer. It is a multi-step process involving invasion and migration of primary tumor cells with a subsequent colonization of these cells at a secondary location. The aim of the present study was to investigate the role of thioredoxin (Trx1 in the invasion and migration of breast cancer cells and to assess the strength of the association between high levels of Trx1 and thioredoxin reductase (TrxR1 expression with breast cancer patient survival. Our results indicate that the expression of both Trx1 and TrxR1 are statistically significantly increased in breast cancer patient cells compared with paired normal breast tissue from the same patient. Over-expression of Trx1 in MDA-MB-231 breast cancer cell lines enhanced cell invasion in in vitro assays while expression of a redox inactive mutant form of Trx1 (designated 1SS or the antisense mRNA inhibited cell invasion. Addition of exogenous Trx1 also enhanced cell invasion, while addition of a specific monoclonal antibody that inhibits Trx1 redox function decreased cell invasion. Over-expression of intracellular Trx1 did not increase cell migration but expression of intracellular 1SS inhibited migration. Addition of exogenous Trx1 enhanced cell migration while 1SS had no effect. Treatment with auranofin inhibited TrxR activity, cell migration and clonogenic activity of MDA-MB-231 cells, while increasing reactive oxygen species (ROS levels. Analysis of 25 independent cohorts with 5910 patients showed that Trx1 and TrxR1 were both associated with a poor patient prognosis in terms of overall survival, distant metastasis free survival and disease free survival. Therefore, targeting the Trx system with auranofin or other specific inhibitors may provide improved breast cancer patient outcomes through inhibition of cancer invasion and migration.

  10. The effect of amorphous selenium detector thickness on dual-energy digital breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Yue-Houng, E-mail: yuehoung.hu@gmail.com; Zhao, Wei [Department of Radiology, State University of New York at Stony Brook, L-4 120 Health Sciences Center, Stony Brook, New York 11794-8460 (United States)

    2014-11-01

    Purpose: Contrast enhanced (CE) imaging techniques for both planar digital mammography (DM) and three-dimensional (3D) digital breast tomosynthesis (DBT) applications requires x-ray photon energies higher than the k-edge of iodine (33.2 keV). As a result, x-ray tube potentials much higher (>40 kVp) than those typical for screening mammography must be utilized. Amorphous selenium (a-Se) based direct conversion flat-panel imagers (FPI) have been widely used in DM and DBT imaging systems. The a-Se layer is typically 200 μm thick with quantum detective efficiency (QDE) >87% for x-ray energies below 26 keV. However, QDE decreases substantially above this energy. To improve the object detectability of either CE-DM or CE-DBT, it may be advantageous to increase the thickness (d{sub Se}) of the a-Se layer. Increasing the d{sub Se} will improve the detective quantum efficiency (DQE) at the higher energies used in CE imaging. However, because most DBT systems are designed with partially isocentric geometries, where the gantry moves about a stationary detector, the oblique entry of x-rays will introduce additional blur to the system. The present investigation quantifies the effect of a-Se thickness on imaging performance for both CE-DM and CE-DBT, discussing the effects of improving photon absorption and blurring from oblique entry of x-rays. Methods: In this paper, a cascaded linear system model (CLSM) was used to investigate the effect of d{sub Se} on the imaging performance (i.e., MTF, NPS, and DQE) of FPI in CE-DM and CE-DBT. The results from the model are used to calculate the ideal observer signal-to-noise ratio, d′, which is used as a figure-of-merit to determine the total effect of increasing d{sub Se} for CE-DM and CE-DBT. Results: The results of the CLSM show that increasing d{sub Se} causes a substantial increase in QDE at the high energies used in CE-DM. However, at the oblique projection angles used in DBT, the increased length of penetration through a

  11. Systemic chemotherapy for metastatic breast cancer

    Institute of Scientific and Technical Information of China (English)

    Yannan Zhao; Biyun Wang

    2015-01-01

    Breast cancer is the leading cause of cancer among women worldwide and the most common cancer in China. Many factors influence the treatment strategy for metastatic breast cancer (MBC). Chemotherapy should be administered to patients with hormone receptor-negative tumors, symptomatic visceral metastasis, and a short disease-free interval. Sequential single-agent chemotherapy has similar efficacy as combination agents in terms of overall survival and quality of life. Anthracyclines are the cornerstone of first-line treatment for MBC, and taxanes represent the second treatment option after resistance. When progression or intolerable toxicity occurs after optimal treatment, the alternative treatments include capecitabine, vinorel-bine, and gemcitabine. Ixabepilone and eribulin are relatively new effective single agents. A combination of cytotoxic agents for patients with rapid clinical progression can further improve the overall response rate and time to progression compared to single-agent treatment. For patients with MBC who were pretreated with anthracyclines in the neoadjuvant/adjuvant setting, a taxane-containing regimen such as docetaxel plus capecitabine or gemcitabine plus paclitaxel should be administered. Platinum-based therapies such as cisplatin or carboplatin have a role in the treatment of triple-negative breast cancer. Meanwhile, the efficacy of the addition of targeted drugs such as iniparib, bevacizumab, and cetuximab to chemotherapy remains unproven. Maintenance chemotherapy is routinely recommended in clinical practice at present. Patients who were previously treated with paclitaxel and gemcitabine have better progression-free and overall survival with maintenance chemotherapy according to a Korean phase Ⅲ clinical trial. Sequential maintenance treatment with capecitabine monotherapy after capecitabine-based combination chemotherapy (X-based X) appears favorable based on a series of domestic studies.

  12. Molecular imaging of HER2-positive breast cancer: a step toward an individualized 'image and treat' strategy

    DEFF Research Database (Denmark)

    Capala, Jacek; Bouchelouche, Kirsten

    2010-01-01

    HER2 overexpression is correlated with aggressive tumor behavior and poor clinical outcome. Therefore, HER2 has become an important prognostic and predictive factor, as well as a target for molecular therapies. The article reviews recent advances in molecular imaging of HER2 that could facilitate...... individual approaches to targeted therapy of HER2-positive breast cancers....

  13. Detecting breast microcalcifications using super-resolution and wave-equation ultrasound imaging: a numerical phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Lianjie [Los Alamos National Laboratory; Simonetti, Francesco [IMPERIAL COLLEGE LONDON; Huthwaite, Peter [IMPERIAL COLLEGE LONDON; Rosenberg, Robert [UNM; Williamson, Michael [UNM

    2010-01-01

    Ultrasound image resolution and quality need to be significantly improved for breast microcalcification detection. Super-resolution imaging with the factorization method has recently been developed as a promising tool to break through the resolution limit of conventional imaging. In addition, wave-equation reflection imaging has become an effective method to reduce image speckles by properly handling ultrasound scattering/diffraction from breast heterogeneities during image reconstruction. We explore the capabilities of a novel super-resolution ultrasound imaging method and a wave-equation reflection imaging scheme for detecting breast microcalcifications. Super-resolution imaging uses the singular value decomposition and a factorization scheme to achieve an image resolution that is not possible for conventional ultrasound imaging. Wave-equation reflection imaging employs a solution to the acoustic-wave equation in heterogeneous media to backpropagate ultrasound scattering/diffraction waves to scatters and form images of heterogeneities. We construct numerical breast phantoms using in vivo breast images, and use a finite-difference wave-equation scheme to generate ultrasound data scattered from inclusions that mimic microcalcifications. We demonstrate that microcalcifications can be detected at full spatial resolution using the super-resolution ultrasound imaging and wave-equation reflection imaging methods.

  14. Volumetric x-ray coherent scatter imaging of cancer in resected breast tissue: a Monte Carlo study using virtual anthropomorphic phantoms

    Science.gov (United States)

    Lakshmanan, Manu N.; Harrawood, Brian P.; Samei, Ehsan; Kapadia, Anuj J.

    2015-08-01

    Breast cancer patients undergoing surgery often choose to have a breast conserving surgery (BCS) instead of mastectomy for removal of only the breast tumor. If post-surgical analysis such as histological assessment of the resected tumor reveals insufficient healthy tissue margins around the cancerous tumor, the patient must undergo another surgery to remove the missed tumor tissue. Such re-excisions are reported to occur in 20%-70% of BCS patients. A real-time surgical margin assessment technique that is fast and consistently accurate could greatly reduce the number of re-excisions performed in BCS. We describe here a tumor margin assessment method based on x-ray coherent scatter computed tomography (CSCT) imaging and demonstrate its utility in surgical margin assessment using Monte Carlo simulations. A CSCT system was simulated in Geant4 and used to simulate two virtual anthropomorphic CSCT scans of phantoms resembling surgically resected tissue. The resulting images were volume-rendered and found to distinguish cancerous tumors embedded in complex distributions of adipose and fibroglandular breast tissue (as is expected in the breast). The images exhibited sufficient spatial and spectral (i.e. momentum transfer) resolution to classify the tissue in any given voxel as healthy or cancerous. ROC analysis of the classification accuracy revealed an area under the curve of up to 0.97. These results indicate that coherent scatter imaging is promising as a possible fast and accurate surgical margin assessment technique.

  15. Volumetric x-ray coherent scatter imaging of cancer in resected breast tissue: a Monte Carlo study using virtual anthropomorphic phantoms

    International Nuclear Information System (INIS)

    Breast cancer patients undergoing surgery often choose to have a breast conserving surgery (BCS) instead of mastectomy for removal of only the breast tumor. If post-surgical analysis such as histological assessment of the resected tumor reveals insufficient healthy tissue margins around the cancerous tumor, the patient must undergo another surgery to remove the missed tumor tissue. Such re-excisions are reported to occur in 20%–70% of BCS patients. A real-time surgical margin assessment technique that is fast and consistently accurate could greatly reduce the number of re-excisions performed in BCS. We describe here a tumor margin assessment method based on x-ray coherent scatter computed tomography (CSCT) imaging and demonstrate its utility in surgical margin assessment using Monte Carlo simulations. A CSCT system was simulated in Geant4 and used to simulate two virtual anthropomorphic CSCT scans of phantoms resembling surgically resected tissue. The resulting images were volume-rendered and found to distinguish cancerous tumors embedded in complex distributions of adipose and fibroglandular breast tissue (as is expected in the breast). The images exhibited sufficient spatial and spectral (i.e. momentum transfer) resolution to classify the tissue in any given voxel as healthy or cancerous. ROC analysis of the classification accuracy revealed an area under the curve of up to 0.97. These results indicate that coherent scatter imaging is promising as a possible fast and accurate surgical margin assessment technique. (paper)

  16. Large-angle x-ray scatter in Talbot–Lau interferometry for breast imaging

    International Nuclear Information System (INIS)

    Monte Carlo simulations were used to investigate large-angle x-ray scatter at design energy of 25 keV during small field of view (9.6 cm × 5 cm) differential phase contrast imaging of the breast using Talbot–Lau interferometry. Homogenous, adipose and fibroglandular breasts of uniform thickness ranging from 2 to 8 cm encompassing the field of view were modeled. Theoretically determined transmission efficiencies of the gratings were used to validate the Monte Carlo simulations, followed by simulations to determine the x-ray scatter reaching the detector. The recorded x-ray scatter was classified into x-ray photons that underwent at least one Compton interaction (incoherent scatter) and Rayleigh interaction alone (coherent scatter) for further analysis. Monte Carlo based estimates of transmission efficiencies showed good correspondence (r2>0.99) with theoretical estimates. Scatter-to-primary ratio increased with increasing breast thickness, ranging from 0.11 to 0.22 for 2–8 cm thick adipose breasts and from 0.12 to 0.28 for 2–8 cm thick fibroglandular breasts. The analyzer grating reduced incoherent scatter by ∼18% for 2 cm thick adipose breast and by ∼35% for 8 cm thick fibroglandular breast. Coherent scatter was the dominant contributor to the total scatter. Coherent-to-incoherent scatter ratio ranged from 2.2 to 3.1 for 2–8 cm thick adipose breasts and from 2.7 to 3.4 for 2–8 cm thick fibroglandular breasts. (paper)

  17. Differential diagnosis of breast masses in South Korean premenopausal women using diffuse optical spectroscopic imaging

    Science.gov (United States)

    Leproux, Anaïs; Kim, You Me; Min, Jun Won; McLaren, Christine E.; Chen, Wen-Pin; O'Sullivan, Thomas D.; Lee, Seung-ha; Chung, Phil-Sang; Tromberg, Bruce J.

    2016-07-01

    Young patients with dense breasts have a relatively low-positive biopsy rate for breast cancer (˜1 in 7). South Korean women have higher breast density than Westerners. We investigated the benefit of using a functional and metabolic imaging technique, diffuse optical spectroscopic imaging (DOSI), to help the standard of care imaging tools to distinguish benign from malignant lesions in premenopausal Korean women. DOSI uses near-infrared light to measure breast tissue composition by quantifying tissue concentrations of water (ctH2O), bulk lipid (ctLipid), deoxygenated (ctHHb), and oxygenated (ctHbO2) hemoglobin. DOSI spectral signatures specific to abnormal tissue and absent in healthy tissue were also used to form a malignancy index. This study included 19 premenopausal subjects (average age 41±9), corresponding to 11 benign and 10 malignant lesions. Elevated lesion to normal ratio of ctH2O, ctHHb, ctHbO2, total hemoglobin (THb=ctHHb+ctHbO2), and tissue optical index (ctHHb×ctH2O/ctLipid) were observed in the malignant lesions compared to the benign lesions (p90% sensitivity and specificity. Malignant lesions showed significantly higher metabolism and perfusion than benign lesions. DOSI spectral features showed high discriminatory power for distinguishing malignant and benign lesions in dense breasts of the Korean population.

  18. Role of diffusion-weighted imaging as an adjunct to contrast-enhanced breast MRI in evaluating residual breast cancer following neoadjuvant chemotherapy

    International Nuclear Information System (INIS)

    Objective: To investigate whether the addition of diffusion-weighted imaging (DWI) to dynamic contrast-enhanced MRI (DCE-MRI) improves diagnostic performance in predicting pathologic response and residual breast cancer size following neoadjuvant chemotherapy. Materials and methods: A total of 78 consecutive patients who underwent preoperative breast MRI with DWI following neoadjuvant chemotherapy were enrolled. DWI was performed on a 1.5 T system with b values of 0 and 750 s/mm. or on a 3 T system with b values of 0 and 800 or 0 and 1000 s/mm. The images on DCE-MRI alone, DWI alone, and DCE-MRI plus DWI were retrospectively reviewed. We evaluated the diagnostic performances of the three MRI protocols for the detection of residual cancer. The tumor size as predicted by MRI was compared with histopathologic findings. Apparent diffusion coefficient (ADC) values were also compared between the groups with and without residual cancer. Results: Of the 78 patients, 59 (75.6%) had residual cancer. For detection of residual cancer, DCE-MRI plus DWI had higher specificity (80.0%), accuracy (91.0%), and PPV (93.2%) than DCE-MRI or DWI alone (P = 0.004, P = 0.007, and P = 0.034, respectively). The ICC values for residual cancer size between MRI and histopathology were 0.891 for DCE-MRI plus DWI, 0.792 for DCE-MRI, and 0.773 for DWI. ADC values showed no significant differences between residual cancer and chemotherapeutic changes (P = 0.130). Conclusions: The addition of DWI to DCE-MRI significantly improved diagnostic performance in predicting pathologic response and residual breast cancer size after neoadjuvant chemotherapy

  19. Imaging of breast cancer with mid- and long-wave infrared camera.

    Science.gov (United States)

    Joro, R; Lääperi, A-L; Dastidar, P; Soimakallio, S; Kuukasjärvi, T; Toivonen, T; Saaristo, R; Järvenpää, R

    2008-01-01

    In this novel study the breasts of 15 women with palpable breast cancer were preoperatively imaged with three technically different infrared (IR) cameras - micro bolometer (MB), quantum well (QWIP) and photo voltaic (PV) - to compare their ability to differentiate breast cancer from normal tissue. The IR images were processed, the data for frequency analysis were collected from dynamic IR images by pixel-based analysis and from each image selectively windowed regional analysis was carried out, based on angiogenesis and nitric oxide production of cancer tissue causing vasomotor and cardiogenic frequency differences compared to normal tissue. Our results show that the GaAs QWIP camera and the InSb PV camera demonstrate the frequency difference between normal and cancerous breast tissue; the PV camera more clearly. With selected image processing operations more detailed frequency analyses could be applied to the suspicious area. The MB camera was not suitable for tissue differentiation, as the difference between noise and effective signal was unsatisfactory. PMID:18432466

  20. A new automatic image analysis method for assessing estrogen receptors' status in breast tissue specimens.

    Science.gov (United States)

    Mouelhi, Aymen; Sayadi, Mounir; Fnaiech, Farhat; Mrad, Karima; Ben Romdhane, Khaled

    2013-12-01

    Manual assessment of estrogen receptors' (ER) status from breast tissue microscopy images is a subjective, time consuming and error prone process. Automatic image analysis methods offer the possibility to obtain consistent, objective and rapid diagnoses of histopathology specimens. In breast cancer biopsies immunohistochemically (IHC) stained for ER, cancer cell nuclei present a large variety in their characteristics that bring various difficulties for traditional image analysis methods. In this paper, we propose a new automatic method to perform both segmentation and classification of breast cell nuclei in order to give quantitative assessment and uniform indicators of IHC staining that will help pathologists in their diagnostic. Firstly, a color geometric active contour model incorporating a spatial fuzzy clustering algorithm is proposed to detect the contours of all cell nuclei in the image. Secondly, overlapping and touching nuclei are separated using an improved watershed algorithm based on a concave vertex graph. Finally, to identify positive and negative stained nuclei, all the segmented nuclei are classified into five categories according to their staining intensity and morphological features using a trained multilayer neural network combined with Fisher's linear discriminant preprocessing. The proposed method is tested on a large dataset containing several breast tissue images with different levels of malignancy. The experimental results show high agreement between the results of the method and ground-truth from the pathologist panel. Furthermore, a comparative study versus existing techniques is presented in order to demonstrate the efficiency and the superiority of the proposed method. PMID:24290943

  1. Breast reconstruction - methods and imaging; Brustaugmentation - Methoden und Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Pfleiderer, B.; Weigel, S.; Hurtienne, B.; Heindel, W. [Universitaetsklinikum Muenster (Germany). Inst. fuer Klinische Radiologie

    2007-12-15

    Silicon implants are used for breast reconstruction or for cosmetic operations. The contribution outlines the role of mammography, sonography and MR for defect assessment, tumour detection and monitoring after prosthesis implantation. Instrument adjustment for mammographic screening of patients with implants is gone into. Autologic reconstruction techniques and protocols of secondary and tertiary early detection are presented. (orig.)

  2. Diagnostic performance of breast specific gamma imaging (BSGI) for breast cancer: Usefulness of dual phase imaging with 99mTc sestamibi

    International Nuclear Information System (INIS)

    The aim of this study was to investigate the usefulness of breast specific gamma imaging (BSGI) with dual phase imaging for increasing diagnostic performance and interpreter confidence. We studied 76 consecutive patients (mean age: 49.3 years, range: 33-61 years) who received 925MBq (25mCi) 99mTc sestamibi intravenously. Craniocaudal and mediolateral oblique planar images were acquired for all patients. Delayed images were obtained from all patients 1h after tracer injection, except for patients with no definite abnormal uptake. All images were classified into four categories: group 1 (definite negative) = no definite abnormal uptake; group 2 (possible negative) = symmetrically diffuse and amorphous uptake; group 3 (possible positive) = asymmetrically mild and nodular uptake; group 4 (definite positive) = asymmetrically intense and nodular uptake. To evaluate diagnostic performance, the BSGI studies were classified as positive (group 3 or 4) or negative (group 1 or 2) for malignancy according to a visual analysis. The final diagnoses were derived from histopathological confirmation and/or imaging follow up after at least 6 months (range: 6-14 months) by both ultrasonography and mammography. The patients' ages ranged from 33 to 61 years, with an average of 49.3 years. Thirteen patients were diagnosed with malignancy, and 63 patients were diagnosed as negative for malignancy. Using early images, 43 patients were classified as group 1, 12 as group 2, 10 as group 3 and 11 as group 4. Based on early images, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of BSGI were 77%, 83%, 48%, 95% and 82%, respectively. Dual phase BSGI had a sensitivity, specificity, PPV, NPV and accuracy of 69%, 95%, 75%, significantly higher with dual phase imaging than with single phase imaging (p=0.0078), but the sensitivity did not differ significantly (p=1.0). Based on dual phase imaging, the sensitivity, specificity, positive

  3. Imagable 4T1 model for the study of late stage breast cancer

    International Nuclear Information System (INIS)

    The 4T1 mouse mammary tumor cell line is one of only a few breast cancer models with the capacity to metastasize efficiently to sites affected in human breast cancer. Here we describe two 4T1 cell lines modified to facilitate analysis of tumor growth and metastasis and evaluation of gene function in vivo. New information regarding the involvement of innate and acquired immunity in metastasis and other characteristics of the model relevant to its use in the study of late stage breast cancer are reported. The lines were engineered for stable expression of firefly luciferase to allow tracking and quantitation of the cells in vivo. Biophotonic imaging was used to characterize growth and metastasis of the lines in vivo and an improved gene expression approach was used to characterize the basis for the metastatic phenotype that was observed. Growth of cells at the primary site was biphasic with metastasis detected during the second growth phase 5–6 weeks after introduction of the cells. Regression of growth, which occurred in weeks 3–4, was associated with extensive necrosis and infiltration of leukocytes. Biphasic tumor growth did not occur in BALB/c SCID mice indicating involvement of an acquired immune response in the effect. Hematopoiesis in spleen and liver and elevated levels of circulating leukocytes were observed at week 2 and increased progressively until death at week 6–8. Gene expression analysis revealed an association of several secreted factors including colony stimulatory factors, cytokines and chemokines, acute phase proteins, angiogenesis factors and ECM modifying proteins with the 4T1 metastatic phenotype. Signaling pathways likely to be responsible for production of these factors were also identified. The production of factors that stimulate angiogenesis and ECM modification and induce hematopoiesis, recruitment and activation of leukocytes suggest that 4T1 tumor cells play a more direct role than previously appreciated in orchestrating changes

  4. Imagable 4T1 model for the study of late stage breast cancer

    Directory of Open Access Journals (Sweden)

    Alroy Joseph

    2008-08-01

    Full Text Available Abstract Background The 4T1 mouse mammary tumor cell line is one of only a few breast cancer models with the capacity to metastasize efficiently to sites affected in human breast cancer. Here we describe two 4T1 cell lines modified to facilitate analysis of tumor growth and metastasis and evaluation of gene function in vivo. New information regarding the involvement of innate and acquired immunity in metastasis and other characteristics of the model relevant to its use in the study of late stage breast cancer are reported. Methods The lines were engineered for stable expression of firefly luciferase to allow tracking and quantitation of the cells in vivo. Biophotonic imaging was used to characterize growth and metastasis of the lines in vivo and an improved gene expression approach was used to characterize the basis for the metastatic phenotype that was observed. Results Growth of cells at the primary site was biphasic with metastasis detected during the second growth phase 5–6 weeks after introduction of the cells. Regression of growth, which occurred in weeks 3–4, was associated with extensive necrosis and infiltration of leukocytes. Biphasic tumor growth did not occur in BALB/c SCID mice indicating involvement of an acquired immune response in the effect. Hematopoiesis in spleen and liver and elevated levels of circulating leukocytes were observed at week 2 and increased progressively until death at week 6–8. Gene expression analysis revealed an association of several secreted factors including colony stimulatory factors, cytokines and chemokines, acute phase proteins, angiogenesis factors and ECM modifying proteins with the 4T1 metastatic phenotype. Signaling pathways likely to be responsible for production of these factors were also identified. Conclusion The production of factors that stimulate angiogenesis and ECM modification and induce hematopoiesis, recruitment and activation of leukocytes suggest that 4T1 tumor cells play a more

  5. Breast MRI, digital mammography and breast tomosynthesis: comparison of three methods for early detection of breast cancer

    Directory of Open Access Journals (Sweden)

    Dragana Roganovic

    2015-11-01

    Full Text Available Breast cancer is the most common malignancy in women and early detection is important for its successful treatment. The aim of this study was to investigate the sensitivity and specificity of three methods for early detection of breast cancer: breast magnetic resonance imaging (MRI, digital mammography, and breast tomosynthesis in comparison to histopathology, as well as to investigate the intraindividual variability between these modalities.  We included 57 breast lesions, each detected by three diagnostic modalities: digital mammography, breast MRI, and breast tomosynthesis, and subsequently confirmed by histopathology. Breast Imaging-Reporting and Data System (BI-RADS was used for characterizing the lesions. One experienced radiologist interpreted all three diagnostic modalities. Twenty-nine of the breast lesions were malignant while 28 were benign. The sensitivity for digital mammography, breast MRI, and breast tomosynthesis, was 72.4%, 93.1%, and 100%, respectively; while the specificity was 46.4%, 60.7%, and 75%, respectively. Receiver operating characteristics (ROC curve analysis showed an overall diagnostic advantage of breast tomosynthesis over both breast MRI and digital mammography. The difference in performance between breast tomosynthesis and digital mammography was significant (p < 0.001, while the difference between breast tomosynthesis and breast MRI was not significant (p = 0.20. 

  6. Optoacoustic imaging of absorbing objects in a turbid medium: ultimate sensitivity and application to breast cancer diagnostics

    International Nuclear Information System (INIS)

    One of the major medical applications of optoacoustic (OA) tomography is in the diagnostics of early-stage breast cancer. A numerical approach was developed to characterize the following parameters of an OA imaging system: resolution, maximum depth at which the tumor can be detected, and image contrast. The parameters of the 64-element focused array transducer were obtained. The results of numerical modeling were compared with known analytical solutions and further validated by phantom experiments. The OA images of a3 mm piece of bovine liver immersed in diluted milk at various depths were obtained. Based on the results of modeling, a signal filtering algorithm for OA image contrast enhancement has been proposed

  7. Stereo-vision system for finger tracking in breast self-examination

    Science.gov (United States)

    Zeng, Jianchao; Wang, Yue J.; Freedman, Matthew T.; Mun, Seong K.

    1997-05-01

    minor changes in illumination. Neighbor search is employed to ensure real time performance, and a three-finger pattern topology is always checked for extracted features to avoid any possible false features. After detecting the features in the images, 3D position parameters of the colored fingers are calculated using the stereo vision principle. In the experiments, a 15 frames/second performance is obtained using an image size of 160 X 120 and an SGI Indy MIPS R4000 workstation. The system is robust and accurate, which confirms the performance and effectiveness of the proposed approach. The system is robust and accurate, which confirms the performance and effectiveness of the proposed approach. The system can be used to quantify search strategy of the palpation and its documentation. With real-time visual feedback, it can be used to train both patients and new physicians to improve their performance of palpation and thus visual feedback, it can be used to train both patients and new physicians to improve their performance of palpation and thus improve the rate of breast tumor detection.

  8. Mammotome breast cancer biopsy: combined guided with X-ray stereotaxis and imaging probe

    International Nuclear Information System (INIS)

    Since 1999 our group started with practical experience on diagnostic use of small, transportable prototypes of high-resolution gamma cameras (patented) for radioguided surgery: the Imaging Probe (IP). First experiences allowed us to develop dedicated prototypes for specific applications. At the moment the most intriguing field is guiding biopsy. Dedicated detectors, characterized by low cost and weight, allow to transfer imaging where the biopsy has to be done. In this paper, a new combined application for breast cancer detection is described. In present system IP is put inside a Fisher digital stereotactic device prepared for Mammotome biopsy: so biopsy can contemporaneously be driven by X-ray stereotaxis and 99mTc-Sestamibi (MIBI) images from IP. The Field Of View (FOV) is about 2x2 cm2 and 0.8 kg weight. This novel scintillation camera is based upon the compact Hamamatsu R7600-00-C8 Position Sensitive Photomultiplier Tube (PSPMT), coupled to scintillating arrays. The PSPMT can be arranged as array when larger FOV is needed. Present application was provided with off line software for image fusion running on the IP dedicated PC. It was matched with the Fisher digital stereotactic X-ray device dedicated to address Mammotome (Ethicon Endo-surgery by Johnson and Johnson) towards breast opacities. Spatial resolution of the IP was 2.5 mm Full-Width Half-Maximum (FWHM) at laboratory tests. A preliminary IP-X-ray digital system inter-calibration was performed using a Perspex-lead phantom. 99mTc MIBI was injected at the dose of 740 MBq 1 h before biopsy to three patients with breast opacities of respectively 0.6, 0.8 and 1.5 cm, scheduled for Mammotome biopsy. Sixty-four pixel scintigraphic images were acquired before and after biopsy in each patient. Operator was allowed to slightly correct the direction of the Mammotome needle taking into account stereotactic X-ray, scintigraphic and fused images. Bioptic samples were also counted with IP before sending them to

  9. 21 CFR 866.6040 - Gene expression profiling test system for breast cancer prognosis.

    Science.gov (United States)

    2010-04-01

    ... cancer prognosis. (a) Identification. A gene expression profiling test system for breast cancer prognosis... previously diagnosed breast cancer. (b) Classification. Class II (special controls). The special control is... Profiling Test System for Breast Cancer Prognosis.” See § 866.1(e) for the availability of this...

  10. Diagnostic imaging of the breast. Examination techniques, appearances, differential diagnosis and interventions. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    This second German edition of the toolbook in the ''RRR'' series of Thieme Verlag gives a full account of the state of the art in diagnostic imaging of the breast. Chapters added are: - Novel imaging techniques for diagnostic evaluation of the female breast, lymph nodes and the male breast. - Digital imaging and MR mammography. - Biopsy techniques and technical tips. New features include: - Compact summaries of the available expert knowledge and experience placed at the end of each chapter. - Full integration of relevant clinical aspects. - Compact and clear description of technical aspects and features and examination techniques. - Guidelines for developing pinpointed diagnostic strategies. - Problem solving strategies for differential diagnosis of typical findings, appearances and special problems, enhanced by decision trees. - Results and recommendations on breast screening and breast imaging reporting. - International and European recommendations on quality assurance. - More than 800 illustrations and schematic drawings. (orig./CB)

  11. The Relationship of Body Image with Psychological Distress in Women with Breast Cancer

    Directory of Open Access Journals (Sweden)

    F Moradi Manesh

    2012-08-01

    Full Text Available Background & aim: Surgery and adjuvant therapies lead to body image problems and psychological distress in young women with breast cancer. The goal of this study was to examine the relationship of body image with psychological distress in women with breast cancer. Methods: This correlation study was carried out on 294 women with breast cancer at Imam Reza Hospital of Kermanshah, Iran, in 2011. The selection of the participants was based on purposive sampling. The Body image was assessed by BIS. The Psychological distress was assessed by DASS-21. The collected data was analyzed by Pearson correlation and Independent sample test. Results: Results showed that body image had a significant positive relationship with psychological distress (P < 0.001. Furthermore, younger women had greater trouble about body image and experienced greater psychological distress compared to elder women. Conclusion: This study showed that dissatisfaction about body image accompanied psychological distress. Also, younger women experience greater difficulties about body image and psychological distress. Therefore, suitable psychological interventions are recommended.

  12. OSPACS: Ultrasound image management system

    Directory of Open Access Journals (Sweden)

    Bessant Conrad

    2008-06-01

    Full Text Available Abstract Background Ultrasound scanning uses the medical imaging format, DICOM, for electronically storing the images and data associated with a particular scan. Large health care facilities typically use a picture archiving and communication system (PACS for storing and retrieving such images. However, these systems are usually not suitable for managing large collections of anonymized ultrasound images gathered during a clinical screening trial. Results We have developed a system enabling the accurate archiving and management of ultrasound images gathered during a clinical screening trial. It is based upon a Windows application utilizing an open-source DICOM image viewer and a relational database. The system automates the bulk import of DICOM files from removable media by cross-validating the patient information against an external database, anonymizing the data as well as the image, and then storing the contents of the file as a field in a database record. These image records may then be retrieved from the database and presented in a tree-view control so that the user can select particular images for display in a DICOM viewer or export them to external media. Conclusion This system provides error-free automation of ultrasound image archiving and management, suitable for use in a clinical trial. An open-source project has been established to promote continued development of the system.

  13. Clinical value of mammography, ultrasound and MR imaging during the first year after breast conserving therapy of breast cancer

    International Nuclear Information System (INIS)

    Purpose: To compare the accuracy of lesion detection and characterization and to determine the agreement of observers, methods and timing of mammography (MX), ultrasound (US) and MR imaging (MRI) during the first year after breast conserving therapy: Materials and Methods: The study included 20 patients diagnosed with breast cancer of stages equal or inferior to T2 N1bi M0 after breast conserving therapy and subsequent radiotherapy. Patients with any history of breast diseases in the affected or contralateral breast were excluded. Patients were examined before and at 3, 6 and 12 months after adjuvant radiotherapy with MX, US and dynamic MR mammography. Additional US and MRI were performed 3 months after radiotherapy. All 220 examinations were retrospectively read in a randomized order by two independent readers, blinded for the results of the other examinations. The outcome after 2.5 years of follow-up was used as gold standard. Histological examination was available in one case. Lesion detection and specificity were assessed including kappa values for different reliabilities between observers, timing and methods. The kappa values were used to characterize the degree of agreement as follows: >0.8 very good; 0.6 - 0.8 good; 0.4 - 0.6 fair; 0.2 - 0.4 minimal; and <0.2 negligible. Results: Based on the interpretation of all available findings (clinical examination, MX, US, MRT and histology in one case), 20 patients observed for a mean period of 2.5 years had no evidence of intramammary recurrence. Therefore the sensitivity of the various methods could not be assessed. The reading of certainly no lesion was given by MRI in 43%, by MX in 30% and by US in 5% of all examinations (p<0.05). True negative findings were observed by MRI in 94.4%, by MX in 90.4% and by US in 82.5%. Reliability between observers, timing and imaging methods was 0.496, 0.411, and 0.215 for lesion detection and 0.303, 0.282, and 0.030 for lesion characterization. (orig.)

  14. The Clinical Utility of Automated Breast Volume Scanner: A Pilot Study of 139 Cases

    OpenAIRE

    Kim, Young Wook; Kim, Seon Kwang; Youn, Hyun Jo; Choi, Eun Jung; Jung, Sung Hoo

    2013-01-01

    Purpose The aim of this study is to evaluate the clinical utility of automated breast volume scanner (ABVS) for detecting and diagnosing the breast lesions. Methods From December 2010 to January 2012, bilateral whole breast examinations were performed with ABVS for 139 women. Based on the Breast Imaging Reporting and Data System (BI-RADS) categories, the breast lesions were evaluated on coronal multiplanar reconstruction images using the ABVS workstation. Then, the imaging results were compar...

  15. Usefulness and biological background of dynamic contrast-enhanced MR images in patients with primary breast cancer

    International Nuclear Information System (INIS)

    Dynamic contrast-enhanced MR images were obtained between September 1998 and May 2000 from 44 primary breast cancer patients who were scheduled to undergo breast-conserving surgery. The MR images and clinico-pathological findings were analyzed to investigate the risk factors for histologically positive margins and histologically positive lymph node metastases. We elucidated the relationship between MR images and the biological background of breast cancer. The following interesting findings were made from these analyses. An irregular shape and unclear border of the tumor mass and the coexistence of daughter nodule(s) were significant risk factors for positive-surgical margins; an irregularly shaped tumor mass and spiculated tumor mass were significant risk factors for positive lymph node metastases; breast tumors with a strand-like appearance had a significantly lower histological grade; breast tumors with high contrast enhancement ratios had a significantly higher nuclear grade and progesterone receptor negativity; and breast tumors showing a ring-like enhancement expressed a low level of VEGF. These findings suggest that preoperative MR images of primary breast cancer provide not only useful information on the extent of breast tumors and the possibility of lymph node metastasis but also on the malignant potency and hormone responsiveness of breast tumors. (author)

  16. The study of 18F-FDG DHC imaging used for diagnosing breast cancer

    International Nuclear Information System (INIS)

    Objective: To explore the diagnostic value of 18F-fluorodeoxyglucose (FDG) dual-head coincidence (DHC) imaging for detecting breast cancer and axillary lymph node metastases. Methods: Thirty-one female patients were studied by 18F-FDG DHC imaging, and 21 of them received fine needle aspiration biopsy after 18F-FDG DHC imaging. The results of 18F-FDG DHC imaging and fine needle aspiration biopsy were compared with those of histopathology. Results: 1) Among the 26 cases of breast carcinoma by 18F-FDG DHC imaging, the FDG uptake of 21 cases showed positive. The lesion diameters ranged from 1.7-8 (mean 3.2 ±1.6) cm, the lesion/background (L/B) ratio range was 1.4-7.3 (mean 2.4 ±1.3). The other 5 malignancies were negative, their diameter range was 0.8-3.3 (mean 1.9) cm. 2) Ten cases of the malignancies were confirmed with axillary lymph node metastases. Three cases by 18F-FDG DHC imaging were positive. Those lymph node diameters were 1.4, 1.8 and 5.2 cm, respectively. The L/B ratios were 1.3, 1.5 and 6.2, respectively. The other 7 cases were negative. The lymph node diameter range was 0.2-1.8 cm. 3) Twenty-one cases received fine needle aspiration biopsy. Tumor cells were found in 13 cases. 4) The sensitivity, specificity and accuracy of 18F-FDG DHC imaging for diagnosing primary breast carcinoma were 80.8%, 5/5 and 83.9%, respectively. The sensitivity, specificity and accuracy of 18F-FDG DHC imaging for diagnosing lymph node metastases were 30.0%, 100% and 77.4%, respectively. The sensitivity, specificity and accuracy of fine needle aspiration biopsy for diagnosing primary breast carcinoma were 72.2%, 3/3 and 76.2%, respectively. 5) There was no significant difference between the sensitivity of 18F-FDG DHC imaging and fine needle aspiration biopsy (P>0.05). Conclusion: 18F-FDG DHC imaging possesses higher sensitivity and specificity in the diagnosis of breast cancer. It can be used as a noninvasive modality for evaluating breast cancer

  17. Similarity based false-positive reduction for breast cancer using radiographic and pathologic imaging features

    Science.gov (United States)

    Pai, Akshay; Samala, Ravi K.; Zhang, Jianying; Qian, Wei

    2010-03-01

    Mammography reading by radiologists and breast tissue image interpretation by pathologists often leads to high False Positive (FP) Rates. Similarly, current Computer Aided Diagnosis (CADx) methods tend to concentrate more on sensitivity, thus increasing the FP rates. A novel method is introduced here which employs similarity based method to decrease the FP rate in the diagnosis of microcalcifications. This method employs the Principal Component Analysis (PCA) and the similarity metrics in order to achieve the proposed goal. The training and testing set is divided into generalized (Normal and Abnormal) and more specific (Abnormal, Normal, Benign) classes. The performance of this method as a standalone classification system is evaluated in both the cases (general and specific). In another approach the probability of each case belonging to a particular class is calculated. If the probabilities are too close to classify, the augmented CADx system can be instructed to have a detailed analysis of such cases. In case of normal cases with high probability, no further processing is necessary, thus reducing the computation time. Hence, this novel method can be employed in cascade with CADx to reduce the FP rate and also avoid unnecessary computational time. Using this methodology, a false positive rate of 8% and 11% is achieved for mammography and cellular images respectively.

  18. Breast Magnetic Resonance Imaging Findings in Women Treated with Toremifene for Premenstrual Mastalgia

    Energy Technology Data Exchange (ETDEWEB)

    Oksa, S. (Dept. of Obstetrics and Gynecology, Satakunta Central Hospital, Pori (Finland)); Parkkola, R. (Dept. of Radiology, Univ. Hospital of Turku, Turku (Finland)); Luukkaala, T.; Maeenpaeae, J. (Medical School, Univ. of Tampere, Tampere (Finland))

    2009-11-15

    Background: Toremifene, a selective estrogen receptor modulator, has been shown to be effective in alleviating premenstrual breast pain. However, the exact mechanism by which toremifene and related compounds work in premenstrual mastalgia is poorly understood. Purpose: To find out if the effect of toremifene on breast would be detectable with dynamic magnetic resonance imaging (MRI). Material and Methods: This randomized, double-blind crossover study was performed on women suffering from marked premenstrual mastalgia. Ten women were randomized to receive either toremifene (20 mg) or placebo from cycle day 15 until next menstruation for three menstrual cycles. After a washout period, the treatment was crossed over for three additional cycles. The MRI evaluations were performed premenstrually at the end of each treatment phase. Breast pain and quality-of-life scores were collected from one baseline cycle and from all the treatment cycles. Results: Nine patients were evaluable for this analysis. Both the enhancement ratio and the maximum slope of enhancement tended to be smaller during the toremifene cycles as compared to placebo. On the left side, the difference in the maximum slope of enhancement between toremifene and placebo was statistically significant (median 5.150 [range 3.7-6.7] and 6.500 [range 4.9-9.5], respectively; P=0.047). T2 relaxation times as well as breast pain and quality-of-life scores were inconsistent. Conclusion: Use of toremifene is associated with measurable changes in dynamic breast MRI findings in women with cyclic breast pain

  19. Application of imaging mass spectrometry for the molecular diagnosis of human breast tumors.

    Science.gov (United States)

    Mao, Xinxin; He, Jiuming; Li, Tiegang; Lu, Zhaohui; Sun, Jian; Meng, Yunxiao; Abliz, Zeper; Chen, Jie

    2016-01-01

    Distinguishing breast invasive ductal carcinoma (IDC) and breast ductal carcinoma in situ (DCIS) is a key step in breast surgery, especially to determine whether DCIS is associated with tumor cell micro-invasion. However, there is currently no reliable method to obtain molecular information for breast tumor analysis during surgery. Here, we present a novel air flow-assisted ionization (AFAI) mass spectrometry imaging method that can be used in ambient environments to differentiate breast cancer by analyzing lipids. In this study, we demonstrate that various subtypes and histological grades of IDC and DCIS can be discriminated using AFAI-MSI: phospholipids were more abundant in IDC than in DCIS, whereas fatty acids were more abundant in DCIS than in IDC. The classification of specimens in the subtype and grade validation sets showed 100% and 78.6% agreement with the histopathological diagnosis, respectively. Our work shows the rapid classification of breast cancer utilizing AFAI-MSI. This work suggests that this method could be developed to provide surgeons with nearly real-time information to guide