WorldWideScience

Sample records for brayton safety feasibility

  1. System safety program plan for the Isotope Brayton Ground Demonstration System (phase I)

    International Nuclear Information System (INIS)

    1976-01-01

    The safety engineering effort to be undertaken in achieving an acceptable level of safety in the Brayton Isotope Power System (BIPS) development program is discussed. The safety organizational relationships, the methods to be used, the tasks to be completed, and the documentation to be published are described. The plan will be updated periodically as the need arises

  2. Impact of closed Brayton cycle test results on gas cooled reactor operation and safety

    International Nuclear Information System (INIS)

    Wright, St.A.; Pickard, P.S.

    2007-01-01

    This report summarizes the measurements and model predictions for a series of tests supported by the U.S. Department of Energy that were performed using the recently constructed Sandia Brayton Loop (SBL-30). From the test results we have developed steady-state power operating curves, controls methodologies, and transient data for normal and off-normal behavior, such as loss of load events, and for decay heat removal conditions after shutdown. These tests and models show that because the turbomachinery operates off of the temperature difference (between the heat source and the heat sink), that the turbomachinery can continue to operate (off of sensible heat) for long periods of time without auxiliary power. For our test hardware, operations up to one hour have been observed. This effect can provide significant operations and safety benefits for nuclear reactors that are coupled to a Brayton cycles because the operating turbomachinery continues to provide cooling to the reactor. These capabilities mean that the decay-heat removal can be accommodated by properly managing the electrical power produced by the generator/alternator. In some conditions, it may even be possible to produce sufficient power to continue operating auxiliary systems including the waste heat circulatory system. In addition, the Brayton plant impacts the consequences of off-normal and accident events including loss of load and loss of on-site power. We have observed that for a loss of load or a loss of on-site power event, with a reactor scram, the transient consists initially of a turbomachinery speed increase to a new stable operating point. Because the turbomachinery is still spinning, the reactor is still being cooled provided the ultimate heat sink remains available. These highly desirable operational characteristics were observed in the Sandia Brayton loop. This type of behavior is also predicted by our models. Ultimately, these results provide the designers the opportunity to design gas

  3. The feasibility study on supercritical methane Recuperated Brayton Cycle for waste heat recovery

    KAUST Repository

    Dyuisenakhmetov, Aibolat

    2017-05-01

    Recuperated Brayton Cycle (RBC) has attracted the attention of research scientists not only as a possible replacement for the steam cycle at nuclear power plants but also as an efficient bottoming cycle for waste heat recovery and for concentrated solar power. RBC’s compactness and the ease at which it can be integrated into existent power plants for waste heat recovery require few modifications. Methane, carbon dioxide and trifluoromethane are analyzed as possible working fluids. This work shows that it is possible to achieve higher efficiencies using methane under some operating conditions. However, as it turns out, the performance of Recuperated Brayton Cycle should be evaluated based on net output work. When the performance is assessed on the net output work criteria carbon dioxide still proves to be superior to other gases. This work also suggests that piston engines as compressors and expanders may be used instead of rotating turbines since reciprocating pistons have higher isentropic efficiencies.

  4. COLD-SAT feasibility study safety analysis

    Science.gov (United States)

    Mchenry, Steven T.; Yost, James M.

    1991-01-01

    The Cryogenic On-orbit Liquid Depot-Storage, Acquisition, and Transfer (COLD-SAT) satellite presents some unique safety issues. The feasibility study conducted at NASA-Lewis desired a systems safety program that would be involved from the initial design in order to eliminate and/or control the inherent hazards. Because of this, a hazards analysis method was needed that: (1) identified issues that needed to be addressed for a feasibility assessment; and (2) identified all potential hazards that would need to be controlled and/or eliminated during the detailed design phases. The developed analysis method is presented as well as the results generated for the COLD-SAT system.

  5. Feasibility and safety of outpatient breast cancer surgery

    DEFF Research Database (Denmark)

    Duriaud, Helle Molter; Kroman, Niels; Kehlet, Henrik

    2018-01-01

    INTRODUCTION: Improvement in perioperative care programmes has facilitated post-operative recovery and use of short-term or outpatient procedures. The aim of this study was to assess the feasibility and safety of an outpatient breast cancer programme in patients referred to a large breast cancer...

  6. Exergy analysis for combined regenerative Brayton and inverse Brayton cycles

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zelong; Chen, Lingen; Sun, Fengrui [College of Naval Architecture and Power, Naval University of Engineering, Wuhan 430033 (China)

    2012-07-01

    This paper presents the study of exergy analysis of combined regenerative Brayton and inverse Brayton cycles. The analytical formulae of exergy loss and exergy efficiency are derived. The largest exergy loss location is determined. By taking the maximum exergy efficiency as the objective, the choice of bottom cycle pressure ratio is optimized by detailed numerical examples, and the corresponding optimal exergy efficiency is obtained. The influences of various parameters on the exergy efficiency and other performances are analyzed by numerical calculations.

  7. Exergy analysis for combined regenerative Brayton and inverse Brayton cycles

    OpenAIRE

    Zelong Zhang, Lingen Chen, Fengrui Sun

    2012-01-01

    This paper presents the study of exergy analysis of combined regenerative Brayton and inverse Brayton cycles. The analytical formulae of exergy loss and exergy efficiency are derived. The largest exergy loss location is determined. By taking the maximum exergy efficiency as the objective, the choice of bottom cycle pressure ratio is optimized by detailed numerical examples, and the corresponding optimal exergy efficiency is obtained. The influences of various parameters on the exergy efficien...

  8. Nuclear power safety reporting system feasibility analysis and concept description

    International Nuclear Information System (INIS)

    Finlayson, F.C.; Ims, J.R.; Hussman, T.A.

    1984-01-01

    The Aerospace Corporation is assisting the US Nuclear Regulatory Commission (NRC) in the evaluation of the potential attributes of a voluntary, nonpunitive data gathering system for identifying and quantifying the factors that contribute to the occurrence of significant safety problems involving humans in nuclear power plants. The objectives of the Aerospace Administration (FAA)/National Aeronautics and Space Administration (NASA) Aviation Safety Reporting System (ASRS) in order to determine whether it would be feasible to apply part (or all) of the ASRS concepts for collecting data on human factor related incidents to the nuclear industry; and (2) to identify and define the basic elements and requirements of a Nuclear Power Safety Reporting System (NPSRS), assuming the feasibility of implementing such a system was established

  9. Safety and feasibility research of CIPT-Ⅱ irradiation device

    International Nuclear Information System (INIS)

    Zhang Zhihua; Mi Xiangmiao; Li Rundong

    2014-01-01

    CITP-Ⅱ irradiation device, which is specially designed for fusion tritium breeder research, works in a thermal neutron reactor. With lithium orthosilicate as the breeder, the safety analysis was done to work out the device's influence on physical parameters of the reactor and get the breeder's temperature distribution and thermo-technical features in the n-γ field. The stiffness and strength were checked, and also the safety characters of the device were assessed. The feasibility of gap gas regulating the temperature and gas refueling the breeder was demonstrated. The calculation and analysis results provide data for comprehensive performance assessment. (authors)

  10. Nuclear-power-safety reporting system: feasibility analysis

    International Nuclear Information System (INIS)

    Finlayson, F.C.; Ims, J.

    1983-04-01

    The US Nuclear Regulatory Commission (NRC) is evaluating the possibility of instituting a data gathering system for identifying and quantifying the factors that contribute to the occurrence of significant safety problems involving humans in nuclear power plants. This report presents the results of a brief (6 months) study of the feasibility of developing a voluntary, nonpunitive Nuclear Power Safety Reporting System (NPSRS). Reports collected by the system would be used to create a data base for documenting, analyzing and assessing the significance of the incidents. Results of The Aerospace Corporation study are presented in two volumes. This document, Volume I, contains a summary of an assessment of the Aviation Safety Reporting System (ASRS). The FAA-sponsored, NASA-managed ASRS was found to be successful, relatively low in cost, generally acceptable to all facets of the aviation community, and the source of much useful data and valuable reports on human factor problems in the nation's airways. Several significant ASRS features were found to be pertinent and applicable for adoption into a NPSRS

  11. Study of reactor Brayton power systems for nuclear electric spacecraft

    Science.gov (United States)

    1979-01-01

    The feasibility of using Brayton power systems for nuclear electric spacecraft was investigated. The primary performance parameters of systems mass and radiator area were determined for systems from 100 to 1000 kW sub e. Mathematical models of all system components were used to determine masses and volumes. Two completely independent systems provide propulsion power so that no single-point failure can jeopardize a mission. The waste heat radiators utilize armored heat pipes to limit meteorite puncture. The armor thickness was statistically determined to achieve the required probability of survival. A 400 kW sub e reference system received primary attention as required by the contract. The components of this system were defined and a conceptual layout was developed with encouraging results. An arrangement with redundant Brayton power systems having a 1500 K (2240 F) turbine inlet temperature was shown to be compatible with the dimensions of the space shuttle orbiter payload bay.

  12. Thermodynamic design of hydrogen liquefaction systems with helium or neon Brayton refrigerator

    Science.gov (United States)

    Chang, Ho-Myung; Ryu, Ki Nam; Baik, Jong Hoon

    2018-04-01

    A thermodynamic study is carried out for the design of hydrogen liquefaction systems with helium (He) or neon (Ne) Brayton refrigerator. This effort is motivated by our immediate goal to develop a small-capacity (100 L/h) liquefier for domestic use in Korea. Eight different cycles are proposed and their thermodynamic performance is investigated in comparison with the existing liquefaction systems. The proposed cycles include the standard and modified versions of He Brayton refrigerators whose lowest temperature is below 20 K. The Brayton refrigerator is in direct thermal contact with the hydrogen flow at atmospheric pressure from ambient-temperature gas to cryogenic liquid. The Linde-Hampson system pre-cooled by a Ne Brayton refrigerator is also considered. Full cycle analysis is performed with the real properties of fluids to estimate the figure of merit (FOM) under an optimized operation condition. It is concluded that He Brayton refrigerators are feasible for this small-scale liquefaction, because a reasonably high efficiency can be achieved with simple and safe (low-pressure) operation. The complete cycles with He Brayton refrigerator are presented for the development of a prototype, including the ortho-to-para conversion.

  13. MR cholangiopancreatography in children: feasibility, safety, and initial experience

    International Nuclear Information System (INIS)

    Delaney, Lisa; Karmazyn, Boaz; Akisik, M.F.; Jennings, S.G.; Applegate, Kimberly E.

    2008-01-01

    The indications for MR cholangiopancreatography (MRCP) in children, and its safety and findings, might differ from those in adults and are not well described. To investigate the safety, feasibility, and accuracy of MRCP in children. We reviewed all prospective MRCP reports, noting the indication, the use of secretin, endoscopic retrograde cholangiopancreatography (ERCP) findings, and patient outcomes. Two readers reviewed each MRCP study by consensus to rate duct visualization and compare pancreatic duct sizes before and after secretin administration (paired t-test). The likelihood of a normal versus an abnormal MRCP study was compared by gender, pancreatitis as the primary indication, secretin use, and whether ERCP was performed (Fisher's exact test), as well as age (t-test). A total of 85 MRCP studies were performed in children (mean age 10.3 years), most commonly for evaluation of pancreatitis (n=47, 55%); 41 (48%) used secretin and 39 (46%) used a negative oral contrast agent. Of the 85 studies, 72 (85%) had excellent image quality and 43 were normal. ERCP was performed after 16 of the 85 MRCP studies (19%); the diagnoses were concordant with those of MRCP in 13 (81%). There were 42 abnormal MRCP studies, and these were more likely to be in girls (P=0.03) and in children who had undergone ERCP (P<0.01). Secretin and the negative oral contrast agent were well-tolerated. Secretin improved duct visualization (P<0.001). MRCP safely and accurately depicted pancreaticobiliary anatomy in children. The use of secretin improved visualization of the pancreatic duct. (orig.)

  14. Nuclear Bi-Brayton system for aircraft propulsion

    International Nuclear Information System (INIS)

    Pierce, B.L.

    1979-01-01

    Recent studies have shown the desirability of new system concept for nuclear aircraft propulsion utilizing the Bi-Brayton system concept, permits coupling of a gas cooled reactor to the power transmission and conversion system in a manner such as to fulfill the safety criteria while eliminating the need for a high temperature intermediate heat exchanger or shaft penetrations of the containment vessel. This system has been shown to minimize the component development required and to allow reduction in total propulsion system weight. This paper presents a description of the system concept and the results of the definition and evaluation studies to date. Parametric and reference system definition studies have been performed. The closed-cycle Bi-Brayton system and component configurations and weight estimates have been derived. Parametric evaluation and cycle variation studies have been performed and interpreted. 7 refs

  15. Brayton cycle space power systems

    International Nuclear Information System (INIS)

    Pietsch, A.; Trimble, S.W.; Harper, A.D.

    1985-01-01

    The latest accomplishments in the design and development of the Brayton Isotope Power System (BIPS) for space applications are described, together with a reexamination of the design/cost tradeoffs with respect to current economic parameters and technology status. The results of tests performed on a ground test version of the flight configuration, the workhorse loop, were used to confirm the performance projections made for the flight system. The results of cost-model analysis indicate that the use of the highest attainable power conversion system efficiency will yield the most cost-effective systems. 13 references

  16. Feasibility, safety and tolerability of accelerated dobutamine stress echocardiography

    Directory of Open Access Journals (Sweden)

    Pavaci Herribert

    2007-11-01

    Full Text Available Abstract A continuous infusion of a single high dose of dobutamine has been, recently, suggested as a simple and effective protocol of stress echocardiography. The present study assesses the feasibility, safety, and tolerability of an accelerated dobutamine stress protocol performed in patients with suspected or known coronary artery disease. Two hundred sixty five consecutive patients underwent accelerated dobutamine stress echocardiography: the dobutamine was administered at a constant dose of 50 μg/kg/min for up to 10 minutes. The mean weight-adjusted cumulative dose of dobutamine used was 330 ± 105.24 μg/kg. Total duration of dobutamine infusion was 6.6 ± 2.1 min. Heart rate rose from 69.9 ± 12.1 to 123.1 ± 22.1 beats/min at peak with a concomitant change in systolic blood pressure (127.6 ± 18.1 vs. 167.6 ± 45.0 mmHg. Dobutamine administration produced a rapid increase in heart rate (9.4 ± 5.9 beats/min2. The side effects were similar to those described with the standard protocol; the most common were frequent premature ventricular complexes (21.5%, frequent premature atrial complexes (1.5% and non sustained ventricular tachycardia (1.5%; among non cardiac symptoms the most frequent were nausea (3.4%, headache (1.1% and symptomatic hypotension (1.1%. No major side effects were observed during the test. Our data demonstrate that a continous infusion of a single high dose of dobutamine is a safe and well tolerated method of performing stress echocardiography in patients with suspected or known coronary artery disease. This new protocol requires the administration of lower cumulative dobutamine dose than standard protocol and results in a significant reduction in test time.

  17. Feasibility of AmbulanCe-Based Telemedicine (FACT) Study : Safety, Feasibility and Reliability of Third Generation Ambulance Telemedicine

    NARCIS (Netherlands)

    Yperzeele, Laetitia; Van Hooff, Robbert-Jan; De Smedt, Ann; Espinoza, Alexis Valenzuela; Van Dyck, Rita; Van de Casseye, Rohny; Convents, Andre; Hubloue, Ives; Lauwaert, Door; De Keyser, Jacques; Brouns, Raf

    2014-01-01

    Background: Telemedicine is currently mainly applied as an in-hospital service, but this technology also holds potential to improve emergency care in the prehospital arena. We report on the safety, feasibility and reliability of in-ambulance teleconsultation using a telemedicine system of the third

  18. Potential application of Rankine and He-Brayton cycles to sodium fast reactors

    International Nuclear Information System (INIS)

    Perez-Pichel, G.D.; Linares, J.I.; Herranz, L.E.; Moratilla, B.Y.

    2011-01-01

    Highlights: → This paper has been focused on thermal efficiency of several Rankine and Brayton cycles for SFR. → A sub-critical Rankine configuration could reach a thermal efficiency higher than 43%. → It could be increased to almost 45% using super-critical configurations. → Brayton cycles thermal performance can be enhanced by adding a super-critical organic fluid Rankine cycle. → The moderate coolant temperature at the reactor makes Brayton configurations have poorer. - Abstract: Traditionally all the demos and/or prototypes of the sodium fast reactor (SFR) technology with power output, have used a steam sub-critical Rankine cycle. Sustainability requirement of Gen. IV reactors recommends exploring alternate power cycle configurations capable of reaching high thermal efficiency. By adopting the anticipated working parameters of next SFRs, this paper investigates the potential of some Rankine and He-Brayton layouts to reach thermal efficiencies as high as feasible, so that they could become alternates for SFR reactor balance of plant. The assessment has encompassed from sub-critical to super-critical Rankine cycles and combined cycles based on He-Brayton gas cycles of different complexity coupled to Organic Rankine Cycles. The sub-critical Rankine configuration reached at thermal efficiency higher than 43%, which has been shown to be a superior performance than any of the He-Brayton configurations analyzed. By adopting a super-critical Rankine arrangement, thermal efficiency would increase less than 1.5%. In short, according to the present study a sub-critical layout seems to be the most promising configuration for all those upcoming prototypes to be operated in the short term (10-15 years). The potential of super-critical CO 2 -Brayton cycles should be explored for future SFRs to be deployed in a longer run.

  19. Closed Brayton cycle power conversion systems for nuclear reactors :

    Energy Technology Data Exchange (ETDEWEB)

    Wright, Steven A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lipinski, Ronald J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Vernon, Milton E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sanchez, Travis [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2006-04-01

    the manufacturers site (Barber-Nichols Inc.) and installed and operated at Sandia. A sufficiently detailed description of the loop is provided in this report along with the design characteristics of the turbo-alternator-compressor set to allow other researchers to compare their results with those measured in the Sandia test-loop. The third task consisted of a validation effort. In this task the test loop was operated and compared with the modeled results to develop a more complete understanding of this electrically heated closed power generation system and to validate the model. The measured and predicted system temperatures and pressures are in good agreement, indicating that the model is a reasonable representation of the test loop. Typical deviations between the model and the hardware results are less than 10%. Additional tests were performed to assess the capability of the Brayton engine to continue to remove decay heat after the reactor/heater is shutdown, to develop safe and effective control strategies, and to access the effectiveness of gas inventory control as an alternative means to provide load following. In one test the heater power was turned off to simulate a rapid reactor shutdown, and the turbomachinery was driven solely by the sensible heat stored in the heater for over 71 minutes without external power input. This is an important safety feature for CBC systems as it means that the closed Brayton loop will keep cooling the reactor without the need for auxiliary power (other than that needed to circulate the waste heat rejection coolant) provided the heat sink is available.

  20. Research and Technology Activities Supporting Closed-Brayton-Cycle Power Conversion System Development

    Science.gov (United States)

    Barrett, Michael J.

    2004-01-01

    The elements of Brayton technology development emphasize power conversion system risk mitigation. Risk mitigation is achieved by demonstrating system integration feasibility, subsystem/component life capability (particularly in the context of material creep) and overall spacecraft mass reduction. Closed-Brayton-cycle (CBC) power conversion technology is viewed as relatively mature. At the 2-kWe power level, a CBC conversion system Technology Readiness Level (TRL) of six (6) was achieved during the Solar Dynamic Ground Test Demonstration (SD-GTD) in 1998. A TRL 5 was demonstrated for 10 kWe-class CBC components during the development of the Brayton Rotating Unit (BRU) from 1968 to 1976. Components currently in terrestrial (open cycle) Brayton machines represent TRL 4 for similar uses in 100 kWe-class CBC space systems. Because of the baseline component and subsystem technology maturity, much of the Brayton technology task is focused on issues related to systems integration. A brief description of ongoing technology activities is given.

  1. Validation of the CATHARE2 code against experimental data from Brayton-cycle plants

    International Nuclear Information System (INIS)

    Bentivoglio, Fabrice; Tauveron, Nicolas; Geffraye, Genevieve; Gentner, Herve

    2008-01-01

    In recent years the Commissariat a l'Energie Atomique (CEA) has commissioned a wide range of feasibility studies of future-advanced nuclear reactors, in particular gas-cooled reactors (GCR). The thermohydraulic behaviour of these systems is a key issue for, among other things, the design of the core, the assessment of thermal stresses, and the design of decay heat removal systems. These studies therefore require efficient and reliable simulation tools capable of modelling the whole reactor, including the core, the core vessel, piping, heat exchangers and turbo-machinery. CATHARE2 is a thermal-hydraulic 1D reference safety code developed and extensively validated for the French pressurized water reactors. It has been recently adapted to deal also with gas-cooled reactor applications. In order to validate CATHARE2 for these new applications, CEA has initiated an ambitious long-term experimental program. The foreseen experimental facilities range from small-scale loops for physical correlations, to component technology and system demonstration loops. In the short-term perspective, CATHARE2 is being validated against existing experimental data. And in particular from the German power plants Oberhausen I and II. These facilities have both been operated by the German utility Energie Versorgung Oberhausen (E.V.O.) and their power conversion systems resemble to the high-temperature reactor concepts: Oberhausen I is a 13.75-MWe Brayton-cycle air turbine plant, and Oberhausen II is a 50-MWe Brayton-cycle helium turbine plant. The paper presents these two plants, the adopted CATHARE2 modelling and a comparison between experimental data and code results for both steady state and transient cases

  2. Safety, feasibility and efficacy of a rapid ART initiation in pregnancy ...

    African Journals Online (AJOL)

    Safety, feasibility and efficacy of a rapid ART initiation in pregnancy pilot programme in Cape Town, South Africa. S Black, R Zulliger, L Myer, R Marcus, S Jeneker, R Taliep, D Pienaar, R Wood, L-G Bekker ...

  3. Cost estimating Brayton and Stirling engines

    Science.gov (United States)

    Fortgang, H. R.

    1980-01-01

    Brayton and Stirling engines were analyzed for cost and selling price for production quantities ranging from 1000 to 400,000 units per year. Parts and components were subjected to indepth scrutiny to determine optimum manufacturing processes coupled with make or buy decisions on materials and small parts. Tooling and capital equipment costs were estimated for each detail and/or assembly. For low annual production volumes, the Brayton engine appears to have a lower cost and selling price than the Stirling Engine. As annual production quantities increase, the Stirling becomes a lower cost engine than the Brayton. Both engines could benefit cost wise if changes were made in materials, design and manufacturing process as annual production quantities increase.

  4. WP-Cave - assessment of feasibility, safety and development potential

    International Nuclear Information System (INIS)

    1989-09-01

    According to SKB R and D-programme 1986, alternative disposal methods will be investigated to provide a basis for selecting a site and a repository system for the Swedish spent nuclear fuel. The present report is a comparison between the WP-Cave and the reference concept KBS-3. The comparison has resulted in the following conclusions: - Both concepts are judged to be able to provide adequate safety. - A utilization of the potential of the WP-Cave requires, however, extensive development in areas where the current state of knowledge and available data are incomplete. - The higher temperatures in the WP-Cave lead to greater uncertainty as to long-term performance. Reducing this uncertainty would require many yaers of research and substantial resources. - Both repositories, including the barriers they incorporate, could be built with a normal adaption of available technology. -It is not possible to say today whether it would be simpler to find suitable sites for one design or the other. - The WP-Cave is considerably more expensive. A future research direction based on a concentrated emplacement of spent fuel along the lines of the WP-Cave is therefore judged to entail greater uncertainty as regards the possibilities of achieving acceptable safety and to require greater resources for research and development, at the same time as the costs of building the repository would be higher. The studies of the WP-Cave as an integral system should therfore be discontinued. Certain barrier designs in the WP-Cave could also be utulized in repository designs with lower temperature, for example the reduction potential of the steel canisters and the hydraulic cage's diversion of groundwater. Studies within these areas are being conducted within SKB and should continue

  5. Effects of hysteresis and Brayton cycle constraints on magnetocaloric refrigerant performance

    Science.gov (United States)

    Brown, T. D.; Buffington, T.; Shamberger, P. J.

    2018-05-01

    Despite promising proofs of concept, system-level implementation of magnetic refrigeration has been critically limited by history-dependent refrigerant losses that interact with governing thermodynamic cycles to adversely impact refrigeration performance. Future development demands a more detailed understanding of how hysteresis limits performance, and of how different types of cycles can mitigate these limitations, but without the extreme cost of experimental realization. Here, the utility of Brayton cycles for magnetic refrigeration is investigated via direct simulation, using a combined thermodynamic-hysteresis modeling framework to compute the path-dependent magnetization and entropy of a model alloy for a variety of feasible Brayton cycles between 0-1.5 T and 0-5 T. By simultaneously varying the model alloy's hysteresis properties and applying extensions of the thermodynamic laws to non-equilibrium systems, heat transfers and efficiencies are quantified throughout the space of hystereses and Brayton cycles and then compared with a previous investigation using Ericsson cycles. It is found that (1) hysteresis losses remain a critical obstacle to magnetic refrigeration implementation, with efficiencies >80% in the model system requiring hysteresis refrigerant transformation temperatures at the relevant fields; (3) for a given hysteresis and field constraint, Brayton and Ericsson-type cycles generate similar efficiencies; for a given temperature span, Ericsson cycles lift more heat per cycle, with the difference decreasing with the refrigerant heat capacity outside the phase transformation region.

  6. Krypton-85 hydrofracture engineering feasibility and safety evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Peretz, F.J.; Muller, M.E.; Pan, P.Y.

    1981-07-01

    Engineering studies have been made to determine the hazards associated with the disposal of /sup 85/Kr using the hydrofracture process. To assess the hazards, an effort has been made to identify the equipment required to entrain and dissolve the noble gas into the grout stream at hydrofracture pressure (up to 350 bar). Off-the-shelf or slightly modified equipment has been identified for safe and effective compression and gas-grout mixing. Each monthly injection disposes of 1.6 x 10/sup 6/ Ci of /sup 85/Kr. By connecting only one gas cylinder to the injection system at a time, the maximum amount of krypton likely to be released as a result of equipment failure is limited to 128,000 Ci. An evaluation by Los Alamos Technical Associates shows that releasing this amount of gas in less than one hour under worst-case meteorological conditions through a 30-m stack would result in a whole-body dose of 170 millirem at a distance of 1 km from the facility. A krypton collection and recovery system can further reduce this dose to 17 millirem; increasing the distance to the site boundary to 3 km can also reduce the dose by a factor of ten. Lung and skin dose estimates are 1.6 and 120 times the whole-body dose, respectively. These are all worst-case values; releases under more typical conditions would result in a significantly lower dose. No insurmountable safety or engineering problems have been identified.

  7. Krypton-85 hydrofracture engineering feasibility and safety evaluation

    International Nuclear Information System (INIS)

    Peretz, F.J.; Muller, M.E.; Pan, P.Y.

    1981-07-01

    Engineering studies have been made to determine the hazards associated with the disposal of 85 Kr using the hydrofracture process. To assess the hazards, an effort has been made to identify the equipment required to entrain and dissolve the noble gas into the grout stream at hydrofracture pressure (up to 350 bar). Off-the-shelf or slightly modified equipment has been identified for safe and effective compression and gas-grout mixing. Each monthly injection disposes of 1.6 x 10 6 Ci of 85 Kr. By connecting only one gas cylinder to the injection system at a time, the maximum amount of krypton likely to be released as a result of equipment failure is limited to 128,000 Ci. An evaluation by Los Alamos Technical Associates shows that releasing this amount of gas in less than one hour under worst-case meteorological conditions through a 30-m stack would result in a whole-body dose of 170 millirem at a distance of 1 km from the facility. A krypton collection and recovery system can further reduce this dose to 17 millirem; increasing the distance to the site boundary to 3 km can also reduce the dose by a factor of ten. Lung and skin dose estimates are 1.6 and 120 times the whole-body dose, respectively. These are all worst-case values; releases under more typical conditions would result in a significantly lower dose. No insurmountable safety or engineering problems have been identified

  8. Virtual reality and persecutory delusions: safety and feasibility.

    Science.gov (United States)

    Fornells-Ambrojo, Miriam; Barker, Chris; Swapp, David; Slater, Mel; Antley, Angus; Freeman, Daniel

    2008-09-01

    Virtual reality (VR) has begun to be used to research the key psychotic symptom of paranoia. The initial studies have been with non-clinical individuals and individuals at high risk of psychosis. The next step is to develop the technology for the understanding and treatment of clinical delusions. Therefore the present study investigated the acceptability and safety of using VR with individuals with current persecutory delusions. Further, it set out to determine whether patients feel immersed in a VR social environment and, consequently, experience paranoid thoughts. Twenty individuals with persecutory delusions and twenty non-clinical individuals spent 4 min in a VR underground train containing neutral characters. Levels of simulator sickness, distress, sense of presence, and persecutory ideation about the computer characters were measured. A one-week follow-up was conducted to check longer-term side effects. The VR experience did not raise levels of anxiety or symptoms of simulator sickness. No side effects were reported at the follow-up. There was a considerable degree of presence in the VR scenario for all participants. A high proportion of the persecutory delusions group (65%) had persecutory thinking about the computer characters, although this rate was not significantly higher than the non-clinical group. The study indicates that brief experiences in VR are safe and acceptable to people with psychosis. Further, patients with paranoia can feel engaged in VR scenes and experience persecutory thoughts. Exposure to social situations using VR has the potential to be incorporated into cognitive behavioural interventions for paranoia.

  9. Feasibility and safety of rehabilitation after venous thromboembolism

    Directory of Open Access Journals (Sweden)

    Noack F

    2015-07-01

    one. Four patients (0.9% had to be transferred to a primary care hospital for non-PE-associated reasons (acute coronary syndrome, pharyngeal abscess, and acute abdominal problems. No influence of any of the physical activity interventions on the incidence of any AE was found. Conclusion: Since PE is a life-threatening disease, it seems reasonable to recommend rehabilitation at least in PE patients with an intermediate or high risk. It is shown for the first time in this study that a standard rehabilitation program after PE is safe. However, efficacy and safety in the long term need to be studied prospectively. Keywords: venous thromboembolism, pulmonary embolism, rehabilitation

  10. Brayton Isotope Power System (BIPS) facility specification

    International Nuclear Information System (INIS)

    1976-01-01

    General requirements for the Brayton Isotope Power System (BIPS)/Ground Demonstration System (GDS) assembly and test facility are defined. The facility will include provisions for a complete test laboratory for GDS checkout, performance, and endurance testing, and a contamination-controlled area for assembly, fabrication, storage, and storage preparation of GDS components. Specifications, schedules, and drawings are included

  11. Brayton Isotope Power System (BIPS) facility specification

    Energy Technology Data Exchange (ETDEWEB)

    1976-05-31

    General requirements for the Brayton Isotope Power System (BIPS)/Ground Demonstration System (GDS) assembly and test facility are defined. The facility will include provisions for a complete test laboratory for GDS checkout, performance, and endurance testing, and a contamination-controlled area for assembly, fabrication, storage, and storage preparation of GDS components. Specifications, schedules, and drawings are included.

  12. Occupational Therapy and Sensory Integration for Children with Autism: A Feasibility, Safety, Acceptability and Fidelity Study

    Science.gov (United States)

    Schaaf, Roseann C.; Benevides, Teal W.; Kelly, Donna; Mailloux-Maggio, Zoe

    2012-01-01

    Objective: To examine the feasibility, safety, and acceptability of a manualized protocol of occupational therapy using sensory integration principles for children with autism. Methods: Ten children diagnosed with autism spectrum disorder ages 4-8 years received intensive occupational therapy intervention using sensory integration principles…

  13. Feasibility and safety of inducing modest hypothermia in awake patients with acute stroke through surface cooling

    DEFF Research Database (Denmark)

    Kammersgaard, L P; Rasmussen, B H; Jørgensen, Henrik Stig

    2000-01-01

    Hypothermia reduces neuronal damage in animal stroke models. Whether hypothermia is neuroprotective in patients with acute stroke remains to be clarified. In this case-control study, we evaluated the feasibility and safety of inducing modest hypothermia by a surface cooling method in awake patients...

  14. Combined leadless pacemaker and subcutaneous implantable defibrillator therapy: feasibility, safety, and performance

    NARCIS (Netherlands)

    Tjong, F. V. Y.; Brouwer, T. F.; Smeding, L.; Kooiman, K. M.; de Groot, J. R.; Ligon, D.; Sanghera, R.; Schalij, M. J.; Wilde, A. A. M.; Knops, R. E.

    2016-01-01

    The subcutaneous implantable cardioverter-defibrillator (S-ICD) and leadless pacemaker (LP) are evolving technologies that do not require intracardiac leads. However, interactions between these two devices are unexplored. We investigated the feasibility, safety, and performance of combined LP and

  15. Performance analysis of different working gases for concentrated solar gas engines: Stirling & Brayton

    International Nuclear Information System (INIS)

    Sharaf Eldean, Mohamed A.; Rafi, Khwaja M.; Soliman, A.M.

    2017-01-01

    Highlights: • Different working gases are used to power on Concentrated Solar Gas Engines. • Gases are used to increase the system efficiency. • Specific heat capacity is considered a vital role for the comparison. • Brayton engine resulted higher design limits. • CO 2 is favorable as a working gas more than C 2 H 2 . - Abstract: This article presents a performance study of using different working fluids (gases) to power on Concentrated Solar Gas Engine (CSGE-Stirling and/or Brayton). Different working gases such as Monatomic (five types), Diatomic (three types) and Polyatomic (four types) are used in this investigation. The survey purported to increase the solar gas engine efficiency hence; decreasing the price of the output power. The effect of using different working gases is noticed on the engine volume, dish area, total plant area, efficiency, compression and pressure ratios thence; the Total Plant Cost (TPC, $). The results reveal that the top cycle temperature effect is reflected on the cycle by increasing the total plant efficiency (2–10%) for Brayton operational case and 5–25% for Stirling operational case. Moreover; Brayton engine resulted higher design limits against the Stirling related to total plant area, m 2 and TPC, $ while generating 1–100 MW e as an economic case study plant. C 2 H 2 achieved remarkable results however, CO 2 is considered for both cycles operation putting in consideration the gas flammability and safety issues.

  16. Feasibility, Safety, and Compliance in a Randomized Controlled Trial of Physical Therapy for Parkinson's Disease

    Directory of Open Access Journals (Sweden)

    Jennifer L. McGinley

    2012-01-01

    Full Text Available Both efficacy and clinical feasibility deserve consideration in translation of research outcomes. This study evaluated the feasibility of rehabilitation programs within the context of a large randomized controlled trial of physical therapy. Ambulant participants with Parkinson's disease (PD (n=210 were randomized into three groups: (1 progressive strength training (PST; (2 movement strategy training (MST; or (3 control (“life skills”. PST and MST included fall prevention education. Feasibility was evaluated in terms of safety, retention, adherence, and compliance measures. Time to first fall during the intervention phase did not differ across groups, and adverse effects were minimal. Retention was high; only eight participants withdrew during or after the intervention phase. Strong adherence (attendance >80% did not differ between groups (P=.435. Compliance in the therapy groups was high. All three programs proved feasible, suggesting they may be safely implemented for people with PD in community-based clinical practice.

  17. Comparative energy analysis on a new regenerative Brayton cycle

    International Nuclear Information System (INIS)

    Goodarzi, M.

    2016-01-01

    Highlights: • New regenerative Brayton cycle has been introduced. • New cycle has higher thermal efficiency and lower exhausted heat per output power. • Regenerator may remain useful in the new cycle even at high pressure ratio. • New regenerative Brayton cycle is suggested for low pressure ratio operations. - Abstract: Gas turbines are frequently used for power generation. Brayton cycle is the basis for gas turbine operation and developing the alternative cycles. Regenerative Brayton cycle is a developed cycle for basic Brayton cycle with higher thermal efficiency at low to moderate pressure ratios. A new regenerative Brayton cycle has been introduced in the present study. Energy analysis has been conducted on ideal cycles to compare them from the first law of thermodynamics viewpoint. Comparative analyses showed that the new regenerative Brayton cycle has higher thermal efficiency than the original one at the same pressure ratio, and also lower heat absorption and exhausted heat per unite output power. Computed results show that new cycle improves thermal efficiency from 12% to 26% relative to the original regenerative Brayton cycle in the range of studied pressure ratios. Contrary to the original regenerative Brayton cycle, regenerator remains useful in the new regenerative Brayton cycle even at higher pressure ratio.

  18. Feasibility of AmbulanCe-Based Telemedicine (FACT study: safety, feasibility and reliability of third generation in-ambulance telemedicine.

    Directory of Open Access Journals (Sweden)

    Laetitia Yperzeele

    Full Text Available Telemedicine is currently mainly applied as an in-hospital service, but this technology also holds potential to improve emergency care in the prehospital arena. We report on the safety, feasibility and reliability of in-ambulance teleconsultation using a telemedicine system of the third generation.A routine ambulance was equipped with a system for real-time bidirectional audio-video communication, automated transmission of vital parameters, glycemia and electronic patient identification. All patients ( ≥ 18 years transported during emergency missions by a Prehospital Intervention Team of the Universitair Ziekenhuis Brussel were eligible for inclusion. To guarantee mobility and to facilitate 24/7 availability, the teleconsultants used lightweight laptop computers to access a dedicated telemedicine platform, which also provided functionalities for neurological assessment, electronic reporting and prehospital notification of the in-hospital team. Key registrations included any safety issue, mobile connectivity, communication of patient information, audiovisual quality, user-friendliness and accuracy of the prehospital diagnosis.Prehospital teleconsultation was obtained in 41 out of 43 cases (95.3%. The success rates for communication of blood pressure, heart rate, blood oxygen saturation, glycemia, and electronic patient identification were 78.7%, 84.8%, 80.6%, 64.0%, and 84.2%. A preliminary prehospital diagnosis was formulated in 90.2%, with satisfactory agreement with final in-hospital diagnoses. Communication of a prehospital report to the in-hospital team was successful in 94.7% and prenotification of the in-hospital team via SMS in 90.2%. Failures resulted mainly from limited mobile connectivity and to a lesser extent from software, hardware or human error. The user acceptance was high.Ambulance-based telemedicine of the third generation is safe, feasible and reliable but further research and development, especially with regard to high

  19. Feasibility studies of safety assessment methods for programmable automation systems. Final report of the AVV project

    International Nuclear Information System (INIS)

    Haapanen, P.; Maskuniitty, M.; Pulkkinen, U.; Heikkinen, J.; Korhonen, J.; Tuulari, E.

    1995-10-01

    Feasibility studies of two different groups of methodologies for safety assessment of programmable automation systems has been executed at the Technical Research Centre of Finland (VTT). The studies concerned the dynamic testing methods and the fault tree (FT) and failure mode and effects analysis (FMEA) methods. In order to get real experience in the application of these methods, an experimental testing of two realistic pilot systems were executed and a FT/FMEA analysis of a programmable safety function accomplished. The purpose of the studies was not to assess the object systems, but to get experience in the application of methods and assess their potentials and development needs. (46 refs., 21 figs.)

  20. Feasibility and safety of augmented reality-assisted urological surgery using smartglass.

    Science.gov (United States)

    Borgmann, H; Rodríguez Socarrás, M; Salem, J; Tsaur, I; Gomez Rivas, J; Barret, E; Tortolero, L

    2017-06-01

    To assess the feasibility, safety and usefulness of augmented reality-assisted urological surgery using smartglass (SG). Seven urological surgeons (3 board urologists and 4 urology residents) performed augmented reality-assisted urological surgery using SG for 10 different types of operations and a total of 31 urological operations. Feasibility was assessed using technical metadata (number of photographs taken/number of videos recorded/video time recorded) and structured interviews with the urologists on their use of SG. Safety was evaluated by recording complications and grading according to the Clavien-Dindo classification. Usefulness of SG for urological surgery was queried in structured interviews and in a survey. The implementation of SG use during urological surgery was feasible with no intrinsic (technical defect) or extrinsic (inability to control the SG function) obstacles being observed. SG use was safe as no grade 3-5 complications occurred for the series of 31 urological surgeries of different complexities. Technical applications of SG included taking photographs/recording videos for teaching and documentation, hands-free teleconsultation, reviewing patients' medical records and images and searching the internet for health information. Overall usefulness of SG for urological surgery was rated as very high by 43 % and high by 29 % of surgeons. Augmented reality-assisted urological surgery using SG is both feasible and safe and also provides several useful functions for urological surgeons. Further developments and investigations are required in the near future to harvest the great potential of this exciting technology for urological surgery.

  1. Multi-objective thermodynamic optimization of combined Brayton and inverse Brayton cycles using genetic algorithms

    International Nuclear Information System (INIS)

    Besarati, S.M.; Atashkari, K.; Jamali, A.; Hajiloo, A.; Nariman-zadeh, N.

    2010-01-01

    This paper presents a simultaneous optimization study of two outputs performance of a previously proposed combined Brayton and inverse Brayton cycles. It has been carried out by varying the upper cycle pressure ratio, the expansion pressure of the bottom cycle and using variable, above atmospheric, bottom cycle inlet pressure. Multi-objective genetic algorithms are used for Pareto approach optimization of the cycle outputs. The two important conflicting thermodynamic objectives that have been considered in this work are net specific work (w s ) and thermal efficiency (η th ). It is shown that some interesting features among optimal objective functions and decision variables involved in the Baryton and inverse Brayton cycles can be discovered consequently.

  2. Brayton-Cycle Baseload Power Tower CSP System

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Bruce [Wilson Solarpower Corporation, Boston, MA (United States)

    2013-12-31

    The primary objectives of Phase 2 of this Project were:1. Engineer, fabricate, and conduct preliminary testing on a low-pressure, air-heating solar receiver capable of powering a microturbine system to produce 300kWe while the sun is shining while simultaneously storing enough energy thermally to power the system for up to 13 hours thereafter. 2. Cycle-test a high-temperature super alloy, Haynes HR214, to determine its efficacy for the system’s high-temperature heat exchanger. 3. Engineer the thermal energy storage system. This Phase 2 followed Wilson’s Phase 1, which primarily was an engineering feasibility study to determine a practical and innovative approach to a full Brayton-cycle system configuration that could meet DOE’s targets. Below is a summary table of the DOE targets with Wilson’s Phase 1 Project results. The results showed that a Brayton system with an innovative (low pressure) solar receiver with ~13 hours of dry (i.e., not phase change materials or molten salts but rather firebrick, stone, or ceramics) has the potential to meet or exceed DOE targets. Such systems would consist of pre-engineered, standardized, factory-produced modules to minimize on-site costs while driving down costs through mass production. System sizes most carefully analyzed were in the range of 300 kWe to 2 MWe. Such systems would also use off-the-shelf towers, blowers, piping, microturbine packages, and heliostats. Per DOE’s instructions, LCOEs are based on the elevation and DNI levels of Daggett, CA, for a 100 MWe power plant following 2 GWe of factory production of the various system components.

  3. Safety Improvements on Wood Chippers Currently in Use: A Study on Feasibility in the Italian Context

    Directory of Open Access Journals (Sweden)

    Giorgia Bagagiolo

    2017-12-01

    Full Text Available Following formal opposition by France, the harmonized safety standards regarding manually-loaded wood chippers (EN 13525:2005+A2:2009 which presumed compliance with the Essential Health and Safety Requirements (EHSR required by the Machine Directive (Directive 2006/42/EC, have recently been withdrawn, and a new draft of the standard is currently under revision. In order to assess the potential impact of the expected future harmonized standards within the Italian context, this study has examined the main issues in implementing EHSRs on wood chippers already being used. Safety issues regarding wood chippers already in use were identified in an analysis of the draft standard, through the observation of a number of case studies, and qualitative analysis of the essential technical interventions. A number of agricultural and forestry operators and companies participated in the study, pointing out the technical and economic obstacle facing the safety features requested by the pending new standard. It emerged that the main safety issues concerned the implementation of the reverse function, the stop bar, and the protective devices, the infeed chute dimension, the emergency stop function, and the designated feeding area. The possibility of adopting such solutions mainly depends on technical feasibility and costs, but an important role is also played by the attitude towards safety and a lack of adequate information regarding safety obligations and procedures among users.

  4. The SHIELD (Safety & Health Improvement: Enhancing Law Enforcement Departments Study: Feasibility and Findings

    Directory of Open Access Journals (Sweden)

    Kerry Stephen Kuehl

    2014-05-01

    Full Text Available This randomized prospective trial aimed to assess the feasibility and efficacy of a team-based worksite health and safety intervention for law enforcement personnel. Four-hundred and eight subjects were enrolled and half were randomized to meet participants met for weekly, peer-led sessions delivered from a scripted team-based health and safety curriculum. Curriculum addressed: exercise, nutrition, stress, sleep, body weight, injury, and other unhealthy lifestyle behaviours such as smoking and heavy alcohol use. Health and safety questionnaires administered before and after the intervention found significant improvements for increased fruit and vegetable consumption, overall healthy eating, increased sleep quantity and sleep quality, and reduced personal stress.

  5. Echocardiography-based hemodynamic management of left ventricular diastolic dysfunction: a feasibility and safety study.

    Science.gov (United States)

    Shillcutt, Sasha K; Montzingo, Candice R; Agrawal, Ankit; Khaleel, Maseeha S; Therrien, Stacey L; Thomas, Walker R; Porter, Thomas R; Brakke, Tara R

    2014-11-01

    Patients with left ventricular diastolic dysfunction (LVDD) are at increased risk of postoperative adverse events. The primary aim of this study was to evaluate the safety and feasibility of using echocardiography-guided hemodynamic management (EGHEM) during surgery in subjects with LVDD compared to conventional management. The feasibility of using echocardiography to direct a treatment algorithm and clinical outcomes were compared for safety between groups. Subjects were screened for LVDD by preoperative transthoracic echocardiography (TTE) and randomized to the conventional or EGHEM group. Subjects in EGHEM received hemodynamic management based on left ventricular filling patterns on transesophageal echocardiography (TEE). Primary outcomes measured were the feasibility to obtain TEE images and follow a TEE-based treatment algorithm. Safety outcomes also compared the following clinical differences between groups: length of hospitalization, incidence of atrial fibrillation, congestive heart failure (CHF), myocardial infarction, cerebrovascular accident, transient ischemic attack and renal failure measured 30 days postoperatively. Population consisted of 28 surgical subjects (14 in conventional group and 14 in EGHEM group). Mean subject age was 73.4 ± 6.7 years (36% male) in conventional group and 65.9 ± 14.4 years (36% male) in EGHEM group. Procedures included orthopedic (conventional = 29%, EGHEM 36%), general (conventional = 50%, EGHEM = 36%), vascular (conventional = 7%, EGHEM = 21%), and thoracic (conventional = 14%, EGHEM = 7%). There was no statistically significant difference in adverse clinical events between the 2 groups. The EGHEM group had less CHF, atrial fibrillation, and shorter length of stay. Echocardiography-guided hemodynamic management of patients with LVDD during surgery is feasible and may be a safe alternative to conventional management. © 2014, Wiley Periodicals, Inc.

  6. Feasibility and safety of general anesthesia for bronchial thermoplasty: a description of early 10 treatments.

    Science.gov (United States)

    Aizawa, Mariko; Ishihara, Satoshi; Yokoyama, Takeshi; Katayama, Katsuyuki

    2018-03-20

    Bronchial thermoplasty (BT) is a recently introduced bronchoscopic treatment for patients with asthma refractory to pharmacotherapy. Intraprocedural sedation management is important for successful performance of BT. However, the results of general anesthesia in patients undergoing BT have not been well described. The aim of this study was to evaluate the feasibility and safety of general anesthesia in patients undergoing BT. We retrospectively reviewed the records of 10 consecutive BT treatments performed under general anesthesia in 4 patients. The feasibility outcomes were coughing and body movement during the procedure, procedure abandonment, and the relative frequency of thermal activation failure. The safety outcomes were bronchospasm and hypoxemia during the procedure, respiratory symptoms, and the need for oxygen after the procedure. Coughing occurred in two treatments. Neither body movement nor procedure abandonment occurred in any treatments. Neither intraprocedural bronchospasm nor hypoxemia occurred in any treatments. Respiratory symptoms occurred in 7 of 10 treatments within 1 day after the procedure and resolved within 4 days, which is comparable with a previous report. These results indicate that general anesthesia is feasible and safe for patients undergoing BT.

  7. Back work ratio of Brayton cycle; La relacion de trabajo de retroceso de un ciclo Brayton

    Energy Technology Data Exchange (ETDEWEB)

    Malaver de la Fuente, M. [Universidad Maritima del Caribe (Venezuela)]. E-mail: mmf_umc@hotmail.com

    2010-07-15

    This paper analyzes the existing relation between temperatures, back work ratio and net work of Brayton cycle, a cycle that describes gas turbine engines performance. The application of computational software helps to show the influence of back work ratio or coupling ratio, compressor and turbine inlet temperatures in an ideal thermodynamical cycle. The results lead to deduce that the maximum value reached in back work ratio will depend on the ranges of maximum and minimal temperatures of Brayton cycle. [Spanish] En este articulo se estudia la relacion que existe entre las temperaturas, la relacion de trabajo de retroceso y el trabajo neto en el ciclo Brayton, que es el ciclo ideal que describe el comportamiento de los motores de turbina de gas. La aplicacion de programas computarizados ayuda a mostrar la influencia de la relacion de trabajo de retroceso o relacion de acoplamiento, la temperatura de entrada al compresor y la temperatura de entrada a la turbina en este ciclo termodinamico ideal. Los resultados obtenidos permiten deducir que el valor maximo que alcanza la relacion de trabajo de retroceso dependera de los limites de temperatura maxima y minima impuestos en el ciclo Brayton.

  8. A feasibility study for Arizona's roadway safety management process using the Highway Safety Manual and SafetyAnalyst : final report.

    Science.gov (United States)

    2016-07-01

    To enable implementation of the American Association of State Highway Transportation (AASHTO) Highway Safety Manual using : SaftetyAnalyst (an AASHTOWare software product), the Arizona Department of Transportation (ADOT) studied the data assessment :...

  9. Feasibility and Safety of Pressurized Intraperitoneal Aerosol Chemotherapy for Peritoneal Carcinomatosis: A Retrospective Cohort Study

    Directory of Open Access Journals (Sweden)

    Martin Hübner

    2017-01-01

    Full Text Available Background. Pressurized intraperitoneal aerosol chemotherapy (PIPAC has been introduced as a novel repeatable treatment for peritoneal carcinomatosis. The available evidence from the pioneer center suggests good tolerance and high response rates, but independent confirmation is needed. A single-center cohort was analyzed one year after implementation for feasibility and safety. Methods. PIPAC was started in January 2015, and every patient was entered into a prospective database. This retrospective analysis included all consecutive patients operated until April 2016 with emphasis on surgical feasibility and early postoperative outcomes. Results. Forty-two patients (M : F = 8 : 34, median age 66 (59–73 years with 91 PIPAC procedures in total (4×: 1,  3×: 17,  2×: 12, and  1×: 12 were analyzed. Abdominal accessibility rate was 95% (42/44; laparoscopic access was not feasible in 2 patients with previous HIPEC. Median initial peritoneal carcinomatosis index (PCI was 10 (IQR 5–17. Median operation time was 94 min (89–108 with no learning curve observed. One PIPAC application was postponed due to intraoperative intestinal lesion. Overall morbidity was 9% with 7 minor complications (Clavien I-II and one PIPAC-unrelated postoperative mortality. Median postoperative hospital stay was 3 days (2-3. Conclusion. Repetitive PIPAC is feasible in most patients with refractory carcinomatosis of various origins. Intraoperative complications and postoperative morbidity rates were low. This encourages prospective studies assessing oncological efficacy.

  10. Safety and Feasibility of Topical Application of Limonene as a Massage Oil to the Breast.

    Science.gov (United States)

    Miller, Jessica A; Thompson, Patricia A; Hakim, Iman A; Lopez, Ana Maria; Thomson, Cynthia A; Chew, Wade; Hsu, Chiu-Hsieh; Chow, H-H Sherry

    2012-10-01

    Limonene, a major component in citrus oil, has demonstrated anti-cancer effects in preclinical mammary cancer models. However, the effective oral dose translates to a human dose that may not be feasible for chronic dosing. We proposed to evaluate topical application of limonene to the breast as an alternative dosing strategy. We conducted a mouse disposition study to determine whether limonene would be bio available in the mammary tissue after topical application. SKH-1 mice received topical or oral administration of limonene in the form of orange oil every day for 4 weeks. Plasma and mammary pads were collected 4 hrs after the final dosing. We also conducted an exploratory clinical study to evaluate the safety and feasibility of topically applied limonene in the form of orange oil to the breast. Healthy women were recruited to apply orange oil containing massage oil to their breasts daily for four weeks. Safety and feasibility were assessed by reported adverse events, clinical labs, and usage compliance. Pre and post-intervention nipple aspirate fluid (NAF) and plasma were collected for limonene concentration determination. The mouse disposition study showed that topical and oral orange oil administration resulted in similar mammary tissue disposition of limonene with no clinical signs of toxicity. In the clinical study, the topical application of limonene containing massage oil to the breast was found to be safe with high levels of usage compliance for daily application, although NAF and plasma limonene concentrations were not significantly changed after the massage oil application. Our studies showed that limonene is bio available in mammary tissue after topical orange oil application in mice and this novel route of administration to the breast is safe and feasible in healthy women.

  11. Cascaded recompression closed brayton cycle system

    Energy Technology Data Exchange (ETDEWEB)

    Pasch, James J.

    2018-01-02

    The present disclosure is directed to a cascaded recompression closed Brayton cycle (CRCBC) system and method of operation thereof, where the CRCBC system includes a compressor for compressing the system fluid, a separator for generating fluid feed streams for each of the system's turbines, and separate segments of a heater that heat the fluid feed streams to different feed temperatures for the system's turbines. Fluid exiting each turbine is used to preheat the fluid to the turbine. In an embodiment, the amount of heat extracted is determined by operational costs.

  12. Garrett solar Brayton engine/generator status

    Science.gov (United States)

    Anson, B.

    1982-07-01

    The solar advanced gas turbine (SAGT-1) is being developed by the Garrett Turbine Engine Company, for use in a Brayton cycle power conversion module. The engine is derived from the advanced gas turbine (AGT101) now being developd by Garrett and Ford Motor Company for automotive use. The SAGT Program is presently funded for the design, fabrication and test of one engine at Garrett's Phoenix facility. The engine when mated with a solar receiver is called a power conversion module (PCU). The PCU is scheduled to be tested on JPL's test bed concentrator under a follow on phase of the program. Approximately 20 kw of electrical power will be generated.

  13. Cascaded recompression closed brayton cycle system

    Science.gov (United States)

    Pasch, James J.

    2018-01-02

    The present disclosure is directed to a cascaded recompression closed Brayton cycle (CRCBC) system and method of operation thereof, where the CRCBC system includes a compressor for compressing the system fluid, a separator for generating fluid feed streams for each of the system's turbines, and separate segments of a heater that heat the fluid feed streams to different feed temperatures for the system's turbines. Fluid exiting each turbine is used to preheat the fluid to the turbine. In an embodiment, the amount of heat extracted is determined by operational costs.

  14. Feasibility study of applying the passive safety system concept to fusion–fission hybrid reactor

    International Nuclear Information System (INIS)

    Yu, Zhang-cheng; Xie, Heng

    2014-01-01

    The fusion–fission hybrid reactor can produce energy, breed nuclear fuel, and handle the nuclear waste, etc., with the fusion neutron source striking the subcritical blanket. The passive safety system consists of passive residual heat removal system, passive safety injection system and automatic depressurization system was adopted into the fusion–fission hybrid reactor in this paper. Modeling and nodalization of primary loop, partial secondary loop and passive core cooling system for the fusion–fission hybrid reactor using relap5 were conducted and small break LOCA on cold leg was analyzed. The results of key transient parameters indicated that the actuation of passive safety system could mitigate the accidental consequence of the 4-inch cold leg small break LOCA on cold leg in the early time effectively. It is feasible to apply the passive safety system concept to fusion–fission hybrid reactor. The minimum collapsed liquid level had great increase if doubling the volume of CMTs to increase its coolant injection and had no increase if doubling the volume of ACCs

  15. Technical feasibility and reliability of passive safety systems of AC600

    International Nuclear Information System (INIS)

    Niu, W.; Zeng, X.

    1996-01-01

    The first step conceptual design of the 600 MWe advanced PWR (AC-600) has been finished by the Nuclear Power Institute of China. Experiments on the passive system of AC-600 are being carried out, and are expected to be completed next year. The main research emphases of AC-600 conceptual design include the advanced core, the passive safety system and simplification. The design objective of AC-600 is that the safety, reliability, maintainability, operation cost and construction period are all improved upon compared to those of PWR plant. One of important means to achieve the objective is using a passive system, which has the following functions whenever its operation is required: providing the reactor core with enough coolant when others fail to make up the lost coolant; reactor residual heat removal; cooling and reducing pressure in the containment and preventing radioactive substances from being released into the environment after occurrence of accident (e.g. LOCA). The system should meet the single failure criterion, and keep operating when a single active component or passive component breaks down during the first 72 hour period after occurrence of accident, or in the long period following the 72 hour period. The passive safety system of AC-600 is composed of the primary safety injection system, the secondary emergency core residual heat removal system and the containment cooling system. The design of the system follows some relevant rules and criteria used by current PWR plant. The system has the ability to bear single failure, two complete separate subsystems are considered, each designed for 100% working capacity. Normal operation is separate from safety operation and avoids cross coupling and interference between systems, improves the reliability of components, and makes it easy to maintain, inspect and test the system. The paper discusses the technical feasibility and reliability of the passive safety system of AC-600, and some issues and test plans are also

  16. Technical feasibility and reliability of passive safety systems of AC600

    Energy Technology Data Exchange (ETDEWEB)

    Niu, W; Zeng, X [Nuclear Power Inst. of China, Chendu (China)

    1996-12-01

    The first step conceptual design of the 600 MWe advanced PWR (AC-600) has been finished. Experiments on the passive system of AC-600 are being carried out, and are expected to be completed next year. The main research emphases of AC-600 conceptual design include the advanced core, the passive safety system and simplification. The design objective of AC-600 is that the safety, reliability, maintainability, operation cost and construction period are all improved upon compared to those of PWR plant. One of important means to achieve the objective is using a passive system, which has the following functions whenever its operation is required: providing the reactor core with enough coolant when others fail to make up the lost coolant; reactor residual heat removal; cooling and reducing pressure in the containment and preventing radioactive substances from being released into the environment after occurrence of accident (e.g. LOCA). The system should meet the single failure criterion, and keep operating when a single active component or passive component breaks down during the first 72 hour period after occurrence of accident, or in the long period following the 72 hour period. The passive safety system of AC-600 is composed of the primary safety injection system, the secondary emergency core residual heat removal system and the containment cooling system. The design of the system follows some relevant rules and criteria used by current PWR plant. The system has the ability to bear single failure, two complete separate subsystems are considered, each designed for 100% working capacity. Normal operation is separate from safety operation and avoids cross coupling and interference between systems, improves the reliability of components, and makes it easy to maintain, inspect and test the system. The paper discusses the technical feasibility and reliability of the passive safety system of AC-600, and some issues and test plans are also involved. (author). 3 figs, 1 tab.

  17. Feasibility study for the adoption of POSRV for KNGR safety depressurization system

    International Nuclear Information System (INIS)

    Kwon, Young Min; Lim, Hong Sik; Song, Jin Ho; Sim, Suk Ku; Park, Jong Kyun

    1999-03-01

    The Korean Next Generation Reactor (KNGR) adopted an advanced design feature of safety depressurization system(SDS) to rapidly de pressurize the reactor coolant system(RCS) in case of beyond design basis events of severe accidents, or a highly unlikely event of a total loss of feedwater (TLOFW) to both steam generators. Two design approaches were considered for the KNGR SDS design. The use of bleed valves similar to those of ABB-CE's system 80+ is design option 1, while in design option 2, the Power Operated Safety Relief valve (POSRV) is considered to provide the combined function of overpressure protection and rapid depressurization. The purpose of this report is to investigate the feasibility of adoption of French SebimPOSRVs for KNGR SDS (design option 2). This report provides the methodology to analyze the TLOFW event with Sebim valves and presents the results of thermal hydraulic analyses using a best-estimate version CEFLASH-4AS/REM for the TLOFW event with feed and bleed. The analyses were performed using a preliminary KNGR design data. For design option 2, if the operator opens two out of the three Sebim valves in conjunction with the four HPSI pumps before a hot leg saturation condition, the decay heat removal and core inventory make-up function can be successfully accomplished. The results of the present investigation demonstrate that the two design options are both feasible to mitigate the consequences of the TLOFW event with a sufficient margin. (Author). 22 refs., 3 tabs., 19 figs

  18. Comparative thermodynamic performance of some Rankine/Brayton cycle configurations for a low-temperature energy application

    Science.gov (United States)

    Lansing, F. L.

    1977-01-01

    Various configurations combining solar-Rankine and fuel-Brayton cycles were analyzed in order to find the arrangement which has the highest thermal efficiency and the smallest fuel share. A numerical example is given to evaluate both the thermodynamic performance and the economic feasibility of each configuration. The solar-assisted regenerative Rankine cycle was found to be leading the candidates from both points of energy utilization and fuel conservation.

  19. Safety and feasibility of fasting in combination with platinum-based chemotherapy

    International Nuclear Information System (INIS)

    Dorff, Tanya B.; Groshen, Susan; Garcia, Agustin; Shah, Manali; Tsao-Wei, Denice; Pham, Huyen; Cheng, Chia-Wei; Brandhorst, Sebastian; Cohen, Pinchas; Wei, Min; Longo, Valter; Quinn, David I.

    2016-01-01

    Short-term starvation prior to chemotherapy administration protects mice against toxicity. We undertook dose-escalation of fasting prior to platinum-based chemotherapy to determine safety and feasibility in cancer patients. 3 cohorts fasted before chemotherapy for 24, 48 and 72 h (divided as 48 pre-chemo and 24 post-chemo) and recorded all calories consumed. Feasibility was defined as ≥ 3/6 subjects in each cohort consuming ≤ 200 kcal per 24 h during the fast period without excess toxicity. Oxidative stress was evaluated in leukocytes using the COMET assay. Insulin, glucose, ketones, insulin-like growth factor-1 (IGF-1) and IGF binding proteins (IGFBPs) were measured as biomarkers of the fasting state. The median age of our 20 subjects was 61, and 85 % were women. Feasibility criteria were met. Fasting-related toxicities were limited to ≤ grade 2, most commonly fatigue, headache, and dizziness. The COMET assay indicated reduced DNA damage in leukocytes from subjects who fasted for ≥48 h (p = 0.08). There was a non-significant trend toward less grade 3 or 4 neutropenia in the 48 and 72 h cohorts compared to 24 h cohort (p = 0.17). IGF-1 levels decreased by 30, 33 and 8 % in the 24, 48 and 72 h fasting cohorts respectively after the first fasting period. Fasting for 72 h around chemotherapy administration is safe and feasible for cancer patients. Biomarkers such as IGF-1 may facilitate assessment of differences in chemotherapy toxicity in subgroups achieving the physiologic fasting state. An onging randomized trial is studying the effect of 72 h of fasting. Clinicaltrials.gov: NCT00936364, registered propectively on July 9, 2009. The online version of this article (doi:10.1186/s12885-016-2370-6) contains supplementary material, which is available to authorized users

  20. Safety and feasibility of fasting in combination with platinum-based chemotherapy.

    Science.gov (United States)

    Dorff, Tanya B; Groshen, Susan; Garcia, Agustin; Shah, Manali; Tsao-Wei, Denice; Pham, Huyen; Cheng, Chia-Wei; Brandhorst, Sebastian; Cohen, Pinchas; Wei, Min; Longo, Valter; Quinn, David I

    2016-06-10

    Short-term starvation prior to chemotherapy administration protects mice against toxicity. We undertook dose-escalation of fasting prior to platinum-based chemotherapy to determine safety and feasibility in cancer patients. 3 cohorts fasted before chemotherapy for 24, 48 and 72 h (divided as 48 pre-chemo and 24 post-chemo) and recorded all calories consumed. Feasibility was defined as ≥ 3/6 subjects in each cohort consuming ≤ 200 kcal per 24 h during the fast period without excess toxicity. Oxidative stress was evaluated in leukocytes using the COMET assay. Insulin, glucose, ketones, insulin-like growth factor-1 (IGF-1) and IGF binding proteins (IGFBPs) were measured as biomarkers of the fasting state. The median age of our 20 subjects was 61, and 85 % were women. Feasibility criteria were met. Fasting-related toxicities were limited to ≤ grade 2, most commonly fatigue, headache, and dizziness. The COMET assay indicated reduced DNA damage in leukocytes from subjects who fasted for ≥48 h (p = 0.08). There was a non-significant trend toward less grade 3 or 4 neutropenia in the 48 and 72 h cohorts compared to 24 h cohort (p = 0.17). IGF-1 levels decreased by 30, 33 and 8 % in the 24, 48 and 72 h fasting cohorts respectively after the first fasting period. Fasting for 72 h around chemotherapy administration is safe and feasible for cancer patients. Biomarkers such as IGF-1 may facilitate assessment of differences in chemotherapy toxicity in subgroups achieving the physiologic fasting state. An onging randomized trial is studying the effect of 72 h of fasting. NCT00936364 , registered propectively on July 9, 2009.

  1. Direct transcatheter aortic valve implantation with self-expandable bioprosthesis: Feasibility and safety

    Energy Technology Data Exchange (ETDEWEB)

    Fiorina, Claudia, E-mail: clafiorina@yahoo.it [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Maffeo, Diego; Curello, Salvatore [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Lipartiti, Felicia [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Chizzola, Giuliano [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); D' Aloia, Antonio [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Adamo, Marianna [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Mastropierro, Rosy [Division of Cardiothoracic Anestesiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Gavazzi, Emanuele [Department of Radiology, University of Brescia, Spedali Civili, Brescia (Italy); Ciccarese, Camilla; Chiari, Ermanna [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Ettori, Federica [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy)

    2014-06-15

    Background: Balloon valvuloplasty has been considered a mandatory step of the transcatheter aortic valve implantation (TAVI), although it is not without risk. The aim of this work was to evaluate the feasibility and safety of TAVI performed without pre-dilation (direct TAVI) of the stenosed aortic valve. Material and Methods: Between June 2012 and June 2013, 55 consecutive TAVI performed without pre-dilation at our institution using the self-expandable CoreValve prosthesis (Medtronic, Minneapolis, MN) were analyzed and compared with 45 pre-dilated TAVI performed the previous year. Inclusion criteria were a symptomatic and severe aortic stenosis. Exclusion criteria were defined as presence of pure aortic regurgitation, degenerated surgical bioprosthesis or bicuspid aortic valve and prior procedure of balloon aortic valvuloplasty performed as a bridge to TAVI. Results: High-burden calcification in the device landing zone, assessed by CT scan, was found in most of the patients. The valve size implanted was similar in both groups. Device success was higher in direct TAVI (85% vs. 64%, p = 0.014), mostly driven by a significant lower incidence of paravalvular leak (PVL ≥2; 9% vs. 33%, p = 0.02). Safety combined end point at 30 days was similar in both groups. Conclusion: Compared to TAVI with pre-dilation, direct TAVI is feasible regardless of the presence of bulky calcified aortic valve and the valve size implanted. Device success was higher in direct TAVI, mostly driven by a lower incidence of paravalvular leak. Safety at 30 days was similar in two groups.

  2. Safety and feasibility of platelet rich fibrin matrix injections for treatment of common urologic conditions

    Directory of Open Access Journals (Sweden)

    Ethan L Matz

    2018-01-01

    Full Text Available Purpose: Autologous platelet rich plasma (PRP is used increasingly in a variety of settings. PRP injections have been used for decades to improve angiogenesis and wound healing. They have also been offered commercially in urology with little to no data on safety or efficacy. PRP could theoretically improve multiple urologic conditions, such as erectile dysfunction (ED, Peyronie's disease (PD, and stress urinary incontinence (SUI. A concern with PRP, however, is early washout, a situation potentially avoided by conversion to platelet rich fibrin matrix (PRFM. Before clinical trials can be performed, safety analysis is desirable. We reviewed an initial series of patients receiving PRFM for urologic pathology to assess safety and feasibility. Materials and Methods: Data were reviewed for patients treated with PRFM at our center from November 2012 to July 2017. Patients were observed immediately post-injection and at follow-up for complications and tolerability. Where applicable, International Index of Erectile Function (IIEF-5 scores were reviewed before and after injections for ED and/or PD. Pad use data was collected pre/post injection for SUI. Results: Seventeen patients were identified, with a mean receipt of 2.1 injections per patient. Post-procedural minor adverse events were seen in 3 men, consisting of mild pain at injection site and mild penile bruising. No patients experienced complications at follow-up. No decline was observed in men completing pre/post IIEF-5 evaluations. Conclusions: PRFM appears to be a safe and feasible treatment modality in patients with urologic disease. Further placebo-controlled trials are warranted.

  3. Feasibility and safety of virtual-reality-based early neurocognitive stimulation in critically ill patients.

    Science.gov (United States)

    Turon, Marc; Fernandez-Gonzalo, Sol; Jodar, Mercè; Gomà, Gemma; Montanya, Jaume; Hernando, David; Bailón, Raquel; de Haro, Candelaria; Gomez-Simon, Victor; Lopez-Aguilar, Josefina; Magrans, Rudys; Martinez-Perez, Melcior; Oliva, Joan Carles; Blanch, Lluís

    2017-12-01

    Growing evidence suggests that critical illness often results in significant long-term neurocognitive impairments in one-third of survivors. Although these neurocognitive impairments are long-lasting and devastating for survivors, rehabilitation rarely occurs during or after critical illness. Our aim is to describe an early neurocognitive stimulation intervention based on virtual reality for patients who are critically ill and to present the results of a proof-of-concept study testing the feasibility, safety, and suitability of this intervention. Twenty critically ill adult patients undergoing or having undergone mechanical ventilation for ≥24 h received daily 20-min neurocognitive stimulation sessions when awake and alert during their ICU stay. The difficulty of the exercises included in the sessions progressively increased over successive sessions. Physiological data were recorded before, during, and after each session. Safety was assessed through heart rate, peripheral oxygen saturation, and respiratory rate. Heart rate variability analysis, an indirect measure of autonomic activity sensitive to cognitive demands, was used to assess the efficacy of the exercises in stimulating attention and working memory. Patients successfully completed the sessions on most days. No sessions were stopped early for safety concerns, and no adverse events occurred. Heart rate variability analysis showed that the exercises stimulated attention and working memory. Critically ill patients considered the sessions enjoyable and relaxing without being overly fatiguing. The results in this proof-of-concept study suggest that a virtual-reality-based neurocognitive intervention is feasible, safe, and tolerable, stimulating cognitive functions and satisfying critically ill patients. Future studies will evaluate the impact of interventions on neurocognitive outcomes. Trial registration Clinical trials.gov identifier: NCT02078206.

  4. A Quantitative Feasibility Study on Potential Safety Improvement Effects of Advanced Safety Features in APR-1400 when Applied to OPR-1000

    Energy Technology Data Exchange (ETDEWEB)

    Ualikhan Zhiyenbayev [KAIST, Daejeon (Korea, Republic of); Chung, Dae Wook [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-10-15

    This study aims to test the feasibility of the applications using Probabilistic Safety Assessment (PSA). Particularly, three of those advanced safety features are selected as follows: 1. Providing an additional Emergency Diesel Generator (EDG); 2. Increasing the capacity of Class 1E batteries; 3. Placing a Refueling Water Storage Tank (RWST) inside containment, i.e., change from RWST to IRWST. The Advanced Power Reactor 1400 (APR-1400) adopts several advanced safety features compared to its predecessor, the Optimized Power Reactor 1000 (OPR-1000), which includes an additional Emergency Diesel Generator, increase in battery capacity, in-containment refueling water storage tank (IRWST), and so on. Considering the remarkable advantages of these safety features in safety improvement and the design similarities between APR-1400 and OPR-1000, it is feasible to apply key advanced safety features of APR-1400 to OPR-1000 to enhance the safety. The selected safety features are incorporated into OPR-1000 PSA model using the Advanced Information Management System (AIMS) for PSA and CDFs are re-evaluated for each application and combination of three applications. Based on current results, it is concluded that three of key advanced safety features of APR-1400 can be effectively applied to OPR-1000, resulting in considerable safety improvement. In aggregate, three advanced safety features, which are an additional EDG, increased battery capacity and IRWST, can reduce the CDF of OPR-1000 by more than 15% when applied altogether.

  5. A Quantitative Feasibility Study on Potential Safety Improvement Effects of Advanced Safety Features in APR-1400 when Applied to OPR-1000

    International Nuclear Information System (INIS)

    Ualikhan Zhiyenbayev; Chung, Dae Wook

    2015-01-01

    This study aims to test the feasibility of the applications using Probabilistic Safety Assessment (PSA). Particularly, three of those advanced safety features are selected as follows: 1. Providing an additional Emergency Diesel Generator (EDG); 2. Increasing the capacity of Class 1E batteries; 3. Placing a Refueling Water Storage Tank (RWST) inside containment, i.e., change from RWST to IRWST. The Advanced Power Reactor 1400 (APR-1400) adopts several advanced safety features compared to its predecessor, the Optimized Power Reactor 1000 (OPR-1000), which includes an additional Emergency Diesel Generator, increase in battery capacity, in-containment refueling water storage tank (IRWST), and so on. Considering the remarkable advantages of these safety features in safety improvement and the design similarities between APR-1400 and OPR-1000, it is feasible to apply key advanced safety features of APR-1400 to OPR-1000 to enhance the safety. The selected safety features are incorporated into OPR-1000 PSA model using the Advanced Information Management System (AIMS) for PSA and CDFs are re-evaluated for each application and combination of three applications. Based on current results, it is concluded that three of key advanced safety features of APR-1400 can be effectively applied to OPR-1000, resulting in considerable safety improvement. In aggregate, three advanced safety features, which are an additional EDG, increased battery capacity and IRWST, can reduce the CDF of OPR-1000 by more than 15% when applied altogether

  6. The French underground research laboratory program, contribution to the feasibility and safety studies of geological disposal

    International Nuclear Information System (INIS)

    Hoorelbeke, J.M.; Niezborala, J.M.; Ben Slimane, K.

    2001-01-01

    The paper presents the content of the research program to be performed during the construction and the operation of the National Agency for Radioactive Waste Management's (ANDRA) underground laboratory, located in the east of France. The general architecture of the program is presented. Emphasis is put on an iterative process, the purpose of which is mainly to: Prepare site behavior models before starting each phase of the field work (bore hole drilling, shaft sinking, construction of underground galleries, specific experiments); Test and check each model through actual observations and measurements; Adjust the models to take into account the results of the former phase and predict the results expected during the following one. All these models, after validation, will be exploited during the assessment of the safety related performance of the components of the potential repository as well as the whole facility; Obtain necessary data related to the feasibility study of the disposal facility (mechanical design, thermal design, etc.,) and its safety assessment. The relationship between the experimental program, the conceptual design program and the safety evaluation program is explained in order to reach the project objectives which is the final document set to be provided to French authorities in 2006 according to the French law of December 1991. (author)

  7. Assuring consumer safety without animal testing: a feasibility case study for skin sensitisation.

    Science.gov (United States)

    Maxwell, Gavin; Aleksic, Maja; Aptula, Aynur; Carmichael, Paul; Fentem, Julia; Gilmour, Nicola; Mackay, Cameron; Pease, Camilla; Pendlington, Ruth; Reynolds, Fiona; Scott, Daniel; Warner, Guy; Westmoreland, Carl

    2008-11-01

    Allergic Contact Dermatitis (ACD; chemical-induced skin sensitisation) represents a key consumer safety endpoint for the cosmetics industry. At present, animal tests (predominantly the mouse Local Lymph Node Assay) are used to generate skin sensitisation hazard data for use in consumer safety risk assessments. An animal testing ban on chemicals to be used in cosmetics will come into effect in the European Union (EU) from March 2009. This animal testing ban is also linked to an EU marketing ban on products containing any ingredients that have been subsequently tested in animals, from March 2009 or March 2013, depending on the toxicological endpoint of concern. Consequently, the testing of cosmetic ingredients in animals for their potential to induce skin sensitisation will be subject to an EU marketing ban, from March 2013 onwards. Our conceptual framework and strategy to deliver a non-animal approach to consumer safety risk assessment can be summarised as an evaluation of new technologies (e.g. 'omics', informatics), leading to the development of new non-animal (in silico and in vitro) predictive models for the generation and interpretation of new forms of hazard characterisation data, followed by the development of new risk assessment approaches to integrate these new forms of data and information in the context of human exposure. Following the principles of the conceptual framework, we have been investigating existing and developing new technologies, models and approaches, in order to explore the feasibility of delivering consumer safety risk assessment decisions in the absence of new animal data. We present here our progress in implementing this conceptual framework, with the skin sensitisation endpoint used as a case study. 2008 FRAME.

  8. Brayton dynamic isotope power systems update

    International Nuclear Information System (INIS)

    Davis, K.A.; Pietsch, A.; Casagrande, R.D.

    1986-01-01

    Brayton dynamic power systems are uniquely suited for space applications. They are compact and highly efficient, offer inherent reliability due to only one moving part, and utilize a single phase and inert working fluid. Additional features include gas bearings, constant speed, and operation at essentially constant temperature. The design, utilizing an inert gas working fluid and gas bearing, is unaffected by zero gravity and can be easily started and restarted in space at low temperatures. This paper describes the salient features of the BIPS as a Dynamic Isotope Power System (DIPS), summarizes the development work to date, establishes the maturity of the design, provides an update on materials technology, and reviews systems integration considerations

  9. Brayton Point coal conversion project (NEPCO)

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, W.F. Jr.

    1982-05-01

    The New England Power Company (NEPCO) recently converted Brayton Point Power Station Units 1, 2, and 3 from oil to coal. The coal conversion project is the largest coal conversion project in the nation to date. Stone and Webster Engineering Corporation (SWEC) was hired as the engineer/constructor for the project. Units 1 and 2 are 250-MW Combustion Engineering boilers, and Unit 3 is a 650-MW Babcock and Wilcox boiler. All three units were originally designed to burn pulverized coal but were converted to oil during the years of low oil prices. Studies performed by NEPCO and SWEC indicated that the areas discussed in the following paragraphs required upgrading before the units could efficiently burn coal and meet Federal and State environmental requirements. All units have been converted and are operating. This paper discusses design modifications required to burn coal, startup, and initial operating problems, and solutions.

  10. SP-100/Brayton power system concepts

    International Nuclear Information System (INIS)

    Owen, D.F.

    1989-01-01

    Use of closed Brayton cycle (CBC) power conversion technology has been investigated for use with SP-100 reactors for space power systems. The CBC power conversion technology is being developed by Rockwell International under the Dynamic Isotype Power System (DIPS) and Space Station Freedom solar dynamic power system programs to provide highly efficient power conversion with radioisotype and solar collector heat sources. Characteristics including mass, radiator area, thermal power, and operating temperatures for systems utilizing SP-100 reactor and CBC power conversion technology were determined for systems in the 10-to 100-kWe power range. Possible SP-100 reactor/CBC power system configurations are presented. Advantages of CBC power conversion technology with regard to reactor thermal power, operating temperature, and development status are discussed

  11. Bladder tissue engineering using biocompatible nanofibrous electrospun constructs: feasibility and safety investigation.

    Science.gov (United States)

    Shakhssalim, Nasser; Dehghan, Mohammad Mehdi; Moghadasali, Reza; Soltani, Mohammad Hossein; Shabani, Iman; Soleimani, Masoud

    2012-01-01

    To investigate the feasibility and safety of using biocompatible, nanofibrous electrospun polycaprolactone (PCL) and combination of polylactic acid (PLLA) and PCL mats in a canine model. Plasma-treated electrospun unseeded mats were implanted in three dogs. The first dog was sacrificed after 3 months and the second and third ones after 4 months, and then, the graft was examined macroscopically with subsequent morphological and histochemical evaluation. Both films showed high levels of cell infiltration and tissue formation, but body response to PLLA/PCL mat in comparison to PCL mat was very low. All three implantation models showed the same light microscopic morphology, immunohistochemistry, and scanning electron microscopy results; nevertheless, only the PCL/PLLA model showed favorable clinical results. Based on these data, nanofibrous PLLA/PCL scaffolding could be a suitable material for the bladder tissue engineering; however, it deserves further investigations.

  12. Novel Percutaneous Radiofrequency Ablation of Portal Vein Tumor Thrombus: Safety and Feasibility

    Energy Technology Data Exchange (ETDEWEB)

    Mizandari, Malkhaz [High Technology Medical Center, Tbilisi State Medical University (Georgia); Ao, Guokun [The 309 Hospital of People' s Liberation Army, Department on Oncology (China); Zhang Yaojun; Feng Xi [Imperial College London, Department of Surgery and Cancer (United Kingdom); Shen Qiang [The First Minimally Invasive Department of Eastern Hepatobiliary Surgery Hospital (China); Chen Minshan [Cancer Centre of Sun Yat-Sen University, Department of Hepatobiliary Surgery (China); Lau, Wan Yee [Chinese University of Hong Kong, Department of Surgery, Faculty of Medicine (Hong Kong); Nicholls, Joanna; Jiao Long; Habib, Nagy, E-mail: nagy.habib@imperial.ac.uk [Imperial College London, Department of Surgery and Cancer (United Kingdom)

    2013-02-15

    We report our experience of the safety of partial recanalization of the portal vein using a novel endovascular radiofrequency (RF) catheter for portal vein tumor thrombosis. Six patients with liver cancer and tumor thrombus in the portal vein underwent percutaneous intravascular radiofrequency ablation (RFA) using an endovascular bipolar RF device. A 0.035-inch guidewire was introduced into a tributary of the portal vein and through which a 5G guide catheter was introduced into the main portal vein. After manipulation of the guide catheter over the thrombus under digital subtraction angiography, the endovascular RF device was inserted and activated around the thrombus. There were no observed technique specific complications, such as hemorrhage, vessel perforation, or infection. Post-RFA portography showed partial recanalization of portal vein. RFA of portal vein tumor thrombus in patients with hepatocellular carcinoma is technically feasible and warrants further investigation to assess efficacy compared with current recanalization techniques.

  13. Feasibility and safety of fiber optic micro-imaging in canine peripheral airways.

    Directory of Open Access Journals (Sweden)

    Yijun Liu

    Full Text Available PURPOSE: To assess the feasibility and safety of imaging canine peripheral airways (0.05. Comparing pre-manipulation and post-manipulation values, SpO2 (F = 13.06, P<0.05 and PaO2 (F = 3.01, P = 0.01 were decreased, whereas RR (F = 3.85, P<0.05 was elevated during the manipulation. (3 Self-limited bleeding was observed in one dog; severe bleeding or other complications did not occur. CONCLUSION: Although the new apparatus had little effect on SpO2, PaO2 and RR, it can probe into small peripheral airways (<1 mm, which may provide a new platform for the early diagnosis of bronchiolar diseases.

  14. Feasibility and safety of prehospital administration of bivalirudin in patients with ST-elevation myocardial infarction

    DEFF Research Database (Denmark)

    Sejersten, Maria; Nielsen, Søren Loumann; Engstrøm, Thomas

    2009-01-01

    undergoing angiography with no difference between groups. Bivalirudin was easy to administer in the prehospital setting and did not affect the prehospital run times. In conclusion, the results suggest that prehospital bivalirudin administration is as safe and effective as heparin in the treatment of patients...... of this preliminary study was to describe the feasibility and safety of a switch from prehospital administration of unfractionated heparin to bivalirudin in ST-elevation acute myocardial infarction (STEMI) patients referred for primary percutaneous coronary intervention. Patients with STEMI treated with a 1-mg...... patients (59%) receiving bivalirudin and 72 receiving heparin were followed during hospitalization. The baseline characteristics and prehospital treatment times were comparable between the 2 groups. The thrombolysis in myocardial infarction flow before and after primary percutaneous coronary intervention...

  15. Safety and feasibility of inpatient exercise training in pediatric heart failure: a preliminary report.

    Science.gov (United States)

    McBride, Michael G; Binder, Tracy Jo; Paridon, Stephen M

    2007-01-01

    To determine the safety and feasibility of an inpatient exercise training program for a group of pediatric heart transplantation candidates on multiple inotropic support. Children with end-stage heart disease often require heart transplantation. Currently, no data exist on the safety and feasibility of an inpatient exercise training program in pediatric patients awaiting heart transplantation while on inotropic support. Twenty ambulatory patients (11 male; age, 13.6 +/- 3.2 years) were admitted, listed, and subsequently enrolled into an exercise training program while awaiting heart transplantation. Patient diagnoses consisted of dilated cardiomyopathy (n = 15), restrictive cardiomyopathy (n = 1), and failing single-ventricle physiology (n = 4). Inotropic support consisted of a combination of dobutamine, dopamine, or milrinone. Exercise sessions were scheduled three times a week lasting from 30 to 60 minutes and consisted of aerobic and musculoskeletal conditioning. Over 6.2 +/- 4.2 months, 1,251 of a possible 1,508 exercise training sessions were conducted, with a total of 615 hours (26.3 +/- 2.7 min/session) dedicated to low-intensity aerobic exercise. Reasons for noncompliance included a change in medical status, staffing, or patient cooperation. Two adverse episodes (seizures) occurred, neither of which resulted in termination from the program. No adverse episodes of hypotension or significant complex arrhythmias occurred. No complication of medication administration or loss of intravenous access occurred. Data from this study indicate that pediatric patients on inotropic support as a result of systemic ventricular or biventricular heart failure can safely participate in exercise training programs with relatively moderate to high compliance.

  16. Cervical cancer screening: Safety, acceptability, and feasibility of a single-visit approach in Bulawayo, Zimbabwe.

    Science.gov (United States)

    Fallala, Muriel S; Mash, Robert

    2015-05-05

    Cervical cancer is the commonest cancer amongst African women, and yet preventative services are often inadequate. The purpose of the study was to assess the safety, acceptability and feasibility of visual inspection with acetic acid and cervicography (VIAC) followed by cryotherapy or a loop electrical excision procedure (LEEP) at a single visit for prevention of cancer of the cervix. The United Bulawayo Hospital, Zimbabwe. The study was descriptive, using retrospective data extracted from electronic medical records of women attending the VIAC clinic. Over 24 months 4641 women visited the clinic and were screened for cervical cancer using VIAC. Cryotherapy or LEEP was offered immediately to those that screened positive. Treated women were followed up at three months and one year. The rate of positive results on VIAC testing was 10.8%. Of those who were eligible, 17.0% received immediate cryotherapy, 44.1% received immediate LEEP, 1.9% delayed treatment, and 37.0% were referred to a gynaecologist. No major complications were recorded after cryotherapy or LEEP. Amongst those treated 99.5% expressed satisfaction with their experience. Only 3.2% of those treated at the clinic had a positive result on VIAC one year later. The service was shown to be feasible to sustain over time with the necessary consumables. There were no service-related treatment postponements and the clinic staff and facility were able to meet the demand for the service. A single-visit approach using VIAC, followed by cryotherapy or LEEP, proved to be safe, acceptable and feasible in an urban African setting in Bulawayo, Zimbabwe. Outcomes a year later suggested that treatment had been effective.

  17. Safety and Feasibility of Transradial Access for Visceral Interventions in Patients with Thrombocytopenia.

    Science.gov (United States)

    Titano, J J; Biederman, D M; Marinelli, B S; Patel, R S; Kim, E; Tabori, N E; Nowakowski, F S; Lookstein, R A; Fischman, A M

    2016-05-01

    Transradial access (TRA) has shown lower morbidity and decreased bleeding complications compared to transfemoral access. This study evaluates the safety and feasibility of TRA in thrombocytopenic patients undergoing visceral interventions. Patients who underwent visceral interventions via the radial artery with platelet count less than or equal to 50,000/µL were included in the study. Outcome variables included technical success, access site, bleeding, transfusion, and neurological complications. From July 1, 2012, to May 31, 2015, a total of 1353 peripheral interventions via TRA were performed, of which 85 procedures were performed in 64 patients (mean age 62.2 years) with a platelet count <50,000/µL (median 39,000/µL). Interventions included chemoembolization (n = 46), selective internal radiation therapy (n = 30), and visceral embolization (n = 9). Technical success was 97.6% with two cases of severe vessel spasm requiring ipsilateral femoral crossover. There was no major access site, bleeding, or neurological adverse events at 30 days. Minor access site hematomas occurred in five cases (5.9%) and were treated conservatively in all cases. Pre-procedural platelet transfusions were administered in 23 (27.1%) cases. There was no statistically significant difference in access site or bleeding complications between the transfused and nontransfused groups. Transradial visceral interventions in patients with thrombocytopenia are both feasible and safe, possibly without the need for platelet transfusions.

  18. Thermodynamic Optimization of Supercritical CO{sub 2} Brayton Cycles

    Energy Technology Data Exchange (ETDEWEB)

    Rhim, Dong-Ryul; Park, Sung-Ho; Kim, Su-Hyun; Yeom, Choong-Sub [Institute for Advanced Engineering, Yongin (Korea, Republic of)

    2015-05-15

    The supercritical CO{sub 2} Brayton cycle has been studied for nuclear applications, mainly for one of the alternative power conversion systems of the sodium cooled fast reactor, since 1960's. Although the supercritical CO{sub 2} Brayton cycle has not been expected to show higher efficiency at lower turbine inlet temperature over the conventional steam Rankine cycle, the higher density of supercritical CO{sub 2} like a liquid in the supercritical region could reduce turbo-machinery sizes, and the potential problem of sodium-water reaction with the sodium cooled fast reactor might be solved with the use of CO{sub 2} instead of water. The supercritical CO{sub 2} recompression Brayton cycle was proposed for the better thermodynamic efficiency than for the simple supercritical CO{sub 2} Brayton cycle. Thus this paper presents the efficiencies of the supercritical CO{sub 2} recompression Brayton cycle along with several decision variables for the thermodynamic optimization of the supercritical CO{sub 2} recompression Brayton cycle. The analytic results in this study show that the system efficiency reaches its maximum value at a compressor outlet pressure of 200 bars and a recycle fraction of 30 %, and the lower minimum temperature approach at the two heat exchangers shows higher system efficiency as expected.

  19. Safety and feasibility of transcranial direct current stimulation in pediatric hemiparesis: randomized controlled preliminary study.

    Science.gov (United States)

    Gillick, Bernadette T; Feyma, Tim; Menk, Jeremiah; Usset, Michelle; Vaith, Amy; Wood, Teddi Jean; Worthington, Rebecca; Krach, Linda E

    2015-03-01

    Transcranial direct current stimulation (tDCS) is a form of noninvasive brain stimulation that has shown improved adult stroke outcomes. Applying tDCS in children with congenital hemiparesis has not yet been explored. The primary objective of this study was to explore the safety and feasibility of single-session tDCS through an adverse events profile and symptom assessment within a double-blind, randomized placebo-controlled preliminary study in children with congenital hemiparesis. A secondary objective was to assess the stability of hand and cognitive function. A double-blind, randomized placebo-controlled pretest/posttest/follow-up study was conducted. The study was conducted in a university pediatric research laboratory. Thirteen children, ages 7 to 18 years, with congenital hemiparesis participated. Adverse events/safety assessment and hand function were measured. Participants were randomly assigned to either an intervention group or a control group, with safety and functional assessments at pretest, at posttest on the same day, and at a 1-week follow-up session. An intervention of 10 minutes of 0.7 mA tDCS was applied to bilateral primary motor cortices. The tDCS intervention was considered safe if there was no individual decline of 25% or group decline of 2 standard deviations for motor evoked potentials (MEPs) and behavioral data and no report of adverse events. No major adverse events were found, including no seizures. Two participants did not complete the study due to lack of MEP and discomfort. For the 11 participants who completed the study, group differences in MEPs and behavioral data did not exceed 2 standard deviations in those who received the tDCS (n=5) and those in the control group (n=6). The study was completed without the need for stopping per medical monitor and biostatisticial analysis. A limitation of the study was the small sample size, with data available for 11 participants. Based on the results of this study, tDCS appears to be safe

  20. Preliminary Design of S-CO2 Brayton Cycle for KAIST Micro Modular Reactor

    International Nuclear Information System (INIS)

    Kim, Seong Gu; Kim, Min Gil; Bae, Seong Jun; Lee, Jeong Ik

    2013-01-01

    This paper suggests a complete modular reactor with an innovative concept of reactor cooling by using a supercritical carbon dioxide directly. Authors propose the supercritical CO 2 Brayton cycle (S-CO 2 cycle) as a power conversion system to achieve small volume of power conversion unit (PCU) and to contain the core and PCU in one vessel for the full modularization. This study suggests a conceptual design of small modular reactor including PCU which is named as KAIST Micro Modular Reactor (MMR). As a part of ongoing research of conceptual design of KAIST MMR, preliminary design of power generation cycle was performed in this study. Since the targets of MMR are full modularization of a reactor system with S-CO 2 coolant, authors selected a simple recuperated S-CO 2 Brayton cycle as a power conversion system for KAIST MMR. The size of components of the S-CO 2 cycle is much smaller than existing helium Brayton cycle and steam Rankine cycle, and whole power conversion system can be contained with core and safety system in one containment vessel. From the investigation of the power conversion cycle, recompressing recuperated cycle showed higher efficiency than the simple recuperated cycle. However the volume of heat exchanger for recompressing cycle is too large so more space will be occupied by heat exchanger in the recompressing cycle than the simple recuperated cycle. Thus, authors consider that the simple recuperated cycle is more suitable for MMR. More research for the KAIST MMR will be followed in the future and detailed information of reactor core and safety system will be developed down the road. More refined cycle layout and design of turbomachinery and heat exchanger will be performed in the future study

  1. Power and efficiency optimization for combined Brayton and inverse Brayton cycles

    International Nuclear Information System (INIS)

    Zhang Wanli; Chen Lingen; Sun Fengrui

    2009-01-01

    A thermodynamic model for open combined Brayton and inverse Brayton cycles is established considering the pressure drops of the working fluid along the flow processes and the size constraints of the real power plant using finite time thermodynamics in this paper. There are 11 flow resistances encountered by the gas stream for the combined Brayton and inverse Brayton cycles. Four of these, the friction through the blades and vanes of the compressors and the turbines, are related to the isentropic efficiencies. The remaining flow resistances are always present because of the changes in flow cross-section at the compressor inlet of the top cycle, combustion inlet and outlet, turbine outlet of the top cycle, turbine outlet of the bottom cycle, heat exchanger inlet, and compressor inlet of the bottom cycle. These resistances control the air flow rate and the net power output. The relative pressure drops associated with the flow through various cross-sectional areas are derived as functions of the compressor inlet relative pressure drop of the top cycle. The analytical formulae about the relations between power output, thermal conversion efficiency, and the compressor pressure ratio of the top cycle are derived with the 11 pressure drop losses in the intake, compression, combustion, expansion, and flow process in the piping, the heat transfer loss to the ambient, the irreversible compression and expansion losses in the compressors and the turbines, and the irreversible combustion loss in the combustion chamber. The performance of the model cycle is optimized by adjusting the compressor inlet pressure of the bottom cycle, the air mass flow rate and the distribution of pressure losses along the flow path. It is shown that the power output has a maximum with respect to the compressor inlet pressure of the bottom cycle, the air mass flow rate or any of the overall pressure drops, and the maximized power output has an additional maximum with respect to the compressor pressure

  2. Surgical procedures performed in the neonatal intensive care unit on critically ill neonates: feasibility and safety

    International Nuclear Information System (INIS)

    Mallick, M.S.; Jado, A.M.; Al-Bassam, A.R.

    2008-01-01

    Transferring unstable, ill neonates to and from the operating rooms carries significant risks and can lead to morbidity. We report on our experience in performing certain procedures in critically ill neonates in the neonatal intensive care unit (NICU). We examined the feasibility and safety for such an approach. All surgical procedures performed in the NICU between January 1999 and December 2005 were analyzed in terms of demographic data, diagnosis, preoperative stability of the patient, procedures performed, complications and outcome. Operations were performed at beside in the NICU in critically ill, unstable neonates who needed emergency surgery, in neonates of low birth weight (<1000 gm) and in neonates on special equipments like higher frequency ventilators and nitrous oxide. Thirty-seven surgical procedures were performed including 12 laparotomies, bowel resection and stomies, 7 repairs of congenital diaphragmatic hernias, 4 ligations of patent ductus arteriosus and various others. Birth weights ranged between 850 gm and 3500 gm (mean 2000 gm). Gestational age ranged between 25 to 42 weeks (mean, 33 weeks). Age at surgery was between 1 to 30 days (mean, 30 days). Preoperatively, 19 patients (51.3%) were on inotropic support and all were intubated and mechanically ventilated. There was no mortality related to surgical procedures. Postoperatively, one patient developed wound infection and disruption. Performing major surgical procedures in the NICU is both feasible and safe. It is useful in very low birth weight, critically ill neonates who have definite risk attached to transfer to the operating room. No special area is needed in the NICU to perform complication-free surgery, but designing an operating room within the NICU will be ideal. (author)

  3. TIA triage in emergency department using acute MRI (TIA-TEAM): a feasibility and safety study.

    Science.gov (United States)

    Vora, Nirali; Tung, Christie E; Mlynash, Michael; Garcia, Madelleine; Kemp, Stephanie; Kleinman, Jonathan; Zaharchuk, Greg; Albers, Gregory; Olivot, Jean-Marc

    2015-04-01

    Positive diffusion weighted imaging (DWI) on MRI is associated with increased recurrent stroke risk in TIA patients. Acute MRI aids in TIA risk stratification and diagnosis. To evaluate the feasibility and safety of TIA triage directly from the emergency department (ED) with acute MRI and neurological consultation. Consecutive ED TIA patients assessed by a neurologist underwent acute MRI/MRA of head/neck per protocol and were hospitalized if positive DWI, symptomatic vessel stenosis, or per clinical judgment. Stroke neurologist adjudicated the final TIA diagnosis as definite, possible, or not a cerebrovascular event. Stroke recurrence rates were calculated at 7, 90, 365 days and compared with predicted stroke rates derived from historical DWI and ABCD(2) score data. One hundred twenty-nine enrolled patients had a mean age of 69 years (± 17) and median ABCD(2) score of 3 (interquartile range [IQR] 3-4). During triage, 112 (87%) patients underwent acute MRI after a median of 16 h (IQR 10-23) from symptom onset. No patients experienced a recurrent event before imaging. Twenty-four (21%) had positive DWI and 8 (7%) had symptomatic vessel stenosis. Of the total cohort, 83 (64%) were discharged and 46 (36%) were hospitalized. By one-year follow-up, one patient in each group had experienced a stroke. Of 92 patients with MRI and index cerebrovascular event, recurrent stroke rates were 1.1% at 7 and 90 days. These were similar to predicted recurrence rates. TIA triage in the ED using a protocol with neurological consultation and acute MRI is feasible and safe. The majority of patients were discharged without hospitalization and rates of recurrent stroke were not higher than predicted. © 2014 World Stroke Organization.

  4. Feasibility and safety of GliaSite brachytherapy in treatment of CNS tumors following neurosurgical resection

    Directory of Open Access Journals (Sweden)

    Wernicke A

    2010-01-01

    Full Text Available Purpose: To investigate feasibility and safety of GliaSite brachytherapy for treatment of central nervous system (CNS tumors following neurosurgical resection. We report mature results of long-term follow-up, outcomes and toxicity. Materials and Methods: In the period from 2004 to 2007, 10 consecutive adult patients with recurrent, newly diagnosed, and metastatic brain malignancies underwent GliaSite brachytherapy following maximally safe neurosurgical resection. While 6/10 (60% patients were treated for recurrence, having previously been treated with external beam radiotherapy (EBRT, 4/10 (40% received radiotherapy (RT for the first time. A median dose of 52.0 Gy (range, 45.0 - 60.0 Gy was prescribed to 0.5 cm - 1.0 cm from the balloon surface. Radiation Therapy Oncology Group (RTOG criteria were used to assess toxicities associated with this technique. Follow-up was assessed with MRI scans and was available on all enrolled patients. Results: Median follow-up was 38 months (range, 18 - 57 months. Mean size of GliaSite balloon was 3.4 cm (range, 2.0 - 4.0 cm. Median survival was 14.0 months for the entire cohort after the treatment. The 17.6 and 16.0 months average survival for newly diagnosed and recurrent high grade gliomas (HGG, respectively, translated into a three-month improvement in survival in patients with newly diagnosed HGG compared to historical controls (P = 0.033. There were no RTOG grades 3 or 4 acute or late toxicities. Follow-up magnetic resonance imaging (MRI imaging did not identify radiation necrosis. Conclusions: Our data indicate that treatment with GliaSite brachytherapy is feasible, safe and renders acceptable local control, acute and long-term toxicities. We are embarking on testing larger numbers of patients with this treatment modality.

  5. Feasibility and safety of a novel in vivo model to assess playground falls in children.

    Science.gov (United States)

    Ehrlich, Peter F; Young, Justin G; Ulin, Sheryl; Wooley, Charles; Armstrong, Thomas J; Buschmann, Bethany; Galecki, Andrzej; Ashton-Miller, James A

    2013-07-01

    Falls are the leading cause of nonfatal unintentional injuries among hospitalized children with playground equipment accounting for more than 50%. National standards for playground rung and rail design exist, but there a lack of in vivo models available to test these standards. We developed a novel in vivo model to test rung and rail design. We report the feasibility and safety of the model. A device was built to simulate children hanging onto a playground bar until their hand slips off. This was defined as breakaway strength. The handle unit was mounted on a vertical cable that was mechanically raised and lowered using a linear actuator controlled by the experimenter. The unit was padded and contained a video camera that recorded the posture of the hand during each trial. Breakaway force and torque were recorded as they held onto the handle by LabView software. In addition, standard anthropometrics and grip strength were recorded. Biomedical engineering approved the device. There were 425 eligible students aged 5 years to 11 years. Of these, 93% (397) participated (212 males and 185 females). Ninety-nine percent (396 of 397) completed all three experimental stations, one declined because of fear. There were no injuries and no falls. Average time to complete the study was 22 ± 0.5 minutes. Ninety-one percent of participants were right handed; the ethnicity was representative of the local area with 79% being white. Mean ± SD height, weight, and body mass index for the 397 participants were 1.28 ± 0.11 m, 28.0 ± 8.12 kg, and 16.31 ± 2.59 kg/m², respectively. Hand size, grip strength, and maximum breakaway force increased with age. This model is safe and feasible and maybe a viable method to assess rung and rail design for playgrounds.

  6. Safety and Feasibility of Transradial Access for Visceral Interventions in Patients with Thrombocytopenia

    International Nuclear Information System (INIS)

    Titano, J. J.; Biederman, D. M.; Marinelli, B. S.; Patel, R. S.; Kim, E.; Tabori, N. E.; Nowakowski, F. S.; Lookstein, R. A.; Fischman, A. M.

    2016-01-01

    PurposeTransradial access (TRA) has shown lower morbidity and decreased bleeding complications compared to transfemoral access. This study evaluates the safety and feasibility of TRA in thrombocytopenic patients undergoing visceral interventions.Methods and MaterialsPatients who underwent visceral interventions via the radial artery with platelet count less than or equal to 50,000/µL were included in the study. Outcome variables included technical success, access site, bleeding, transfusion, and neurological complications.ResultsFrom July 1, 2012, to May 31, 2015, a total of 1353 peripheral interventions via TRA were performed, of which 85 procedures were performed in 64 patients (mean age 62.2 years) with a platelet count <50,000/µL (median 39,000/µL). Interventions included chemoembolization (n = 46), selective internal radiation therapy (n = 30), and visceral embolization (n = 9). Technical success was 97.6 % with two cases of severe vessel spasm requiring ipsilateral femoral crossover. There was no major access site, bleeding, or neurological adverse events at 30 days. Minor access site hematomas occurred in five cases (5.9 %) and were treated conservatively in all cases. Pre-procedural platelet transfusions were administered in 23 (27.1 %) cases. There was no statistically significant difference in access site or bleeding complications between the transfused and nontransfused groups.ConclusionsTransradial visceral interventions in patients with thrombocytopenia are both feasible and safe, possibly without the need for platelet transfusions.

  7. Feasibility and Safety of a Transthoracic Pneumostoma Airway Bypass in Severe Emphysema Patients.

    Science.gov (United States)

    Snell, Gregory I; Holsworth, Lynda; Khorramnia, Sadie; Westall, Glen P; Williams, Trevor J; Marasco, Silvana; Gooi, Julian H

    2017-01-01

    Emphysema is characterised by airflow obstruction, hyperinflation, and resultant dyspnoea. It is worth investigating whether decompression improves lung mechanics and enhances quality of life (QoL). The purpose of this study was to describe the feasibility and safety of creating a transthoracic pneumostoma to enable lung reduction. A transthoracic 10-mm diameter Portaero Access Tube (Portaero™, Cupertino, CA, USA) was implanted via a third intercostal space incision in 15 severe emphysema patients [mean age 63 years, forced expiratory volume in 1 s 54% predicted, diffusing capacity for carbon monoxide 31% predicted, residual volume 246% predicted, Six-Minute Walk Test 296 m]. Four weeks later, an 8-mm Portaero Disposable Tube (3-8 cm in length) was substituted and changed daily thereafter. The targeted primary endpoints were a ≥12% increase in forced expiratory volume in 1 s and a decrease of ≥4 points in Saint George's Respiratory Questionnaire score at 6 months. Sixteen procedures were performed on 15 patients, complicated by 1 intercostal haemorrhage, 1 pneumothorax, and universal mild surgical emphysema. Early patency issues were common, but often responded to external endoscopic debridement or argon plasma laser. Three-month patency was achieved in 9 of 15 patients, and 6 of these had long-term patency (mean of 4 years). Patency was associated with potentially useful long-term improvements or stability in spirometry, residual volume, and QoL. However, the primary endpoints were not met at 6 months. The creation and maintenance of a transthoracic pneumostoma appears feasible and safe in patients with severe emphysema. Further studies refining patient selection (perhaps via chest computed tomography collateral ventilation and fissure assessments), techniques, and tube materials are suggested. © 2017 S. Karger AG, Basel.

  8. Sentinel lymph node biopsy in endometrial cancer-Feasibility, safety and lymphatic complications.

    Science.gov (United States)

    Geppert, Barbara; Lönnerfors, Céline; Bollino, Michele; Persson, Jan

    2018-03-01

    To compare the rate of lymphatic complications in women with endometrial cancer undergoing sentinel lymph node biopsy versus a full pelvic and infrarenal paraaortic lymphadenectomy, and to examine the overall feasibility and safety of the former. A prospective study of 188 patients with endometrial cancer planned for robotic surgery. Indocyanine green was used to identify the sentinel lymph nodes. In low-risk patients the lymphadenectomy was restricted to removal of sentinel lymph nodes whereas in high-risk patients also a full lymphadenectomy was performed. The impact of the extent of the lymphadenectomy on the rate of complications was evaluated. The bilateral detection rate of sentinel lymph nodes was 96% after cervical tracer injection. No intraoperative complication was associated with the sentinel lymph node biopsy per se. Compared with hysterectomy alone, the additional average operative time for removal of sentinel lymph nodes was 33min whereas 91min were saved compared with a full pelvic and paraaortic lymphadenectomy. Sentinel lymph node biopsy alone resulted in a lower incidence of leg lymphedema than infrarenal paraaortic and pelvic lymphadenectomy (1.3% vs 18.1%, p=0.0003). The high feasibility, the absence of intraoperative complications and the low risk of lymphatic complications supports implementing detection of sentinel lymph nodes in low-risk endometrial cancer patients. Given that available preliminary data on sensitivity and false negative rates in high-risk patients are confirmed in further studies, we also believe that the reduction in lymphatic complications and operative time strongly motivates the sentinel lymph node concept in high-risk endometrial cancer. Copyright © 2017. Published by Elsevier Inc.

  9. Feasibility and Safety of Endovascular Stripping of Totally Implantable Venous Access Devices

    International Nuclear Information System (INIS)

    Heye, Sam; Maleux, Geert; Goossens, G. A.; Vaninbroukx, Johan; Jerôme, M.; Stas, M.

    2012-01-01

    Purpose: To evaluate the safety and feasibility of percutaneous stripping of totally implantable venous access devices (TIVAD) in case of catheter-related sleeve and to report a technique to free the catheter tip from vessel wall adherence. Materials and Methods: A total of 37 stripping procedures in 35 patients (14 men, 40%, and 21 women, 60%, mean age 53 ± 14 years) were reviewed. Totally implantable venous access devices were implanted because of malignancy in most cases (85.7%). Catheter-related sleeve was confirmed as cause of persistent catheter dysfunction despite instillation of thrombolytics. A technique to mobilize the catheter tip from the vessel wall was used when stripping with the snare catheter was impossible. Technical success, complication rate, and outcome were noted. Results: A total of 55.9% (n = 19) of the 34 technically successful procedures (91.9%) could be done with the snare catheter. In 15 cases (44.1%), additional maneuvers to free the TIVAD’s tip from the vessel wall were needed. Success rate was not significantly lower before (72.4%) than after (96.7%) implementation of the new technique (P = 0.09). No complications were observed. Follow-up was available in 67.6% of cases. Recurrent catheter dysfunction was found in 17 TIVADs (78.3%) at a mean of 137.7 days and a median of 105 days. Conclusions: Stripping of TIVADs is technically feasible and safe, with an overall success rate of 91.9%. Additional endovascular techniques to mobilize the distal catheter tip from the wall of the superior vena cava or right atrium to allow encircling the TIVAD tip with the snare catheter may be needed in 44.1% of cases.

  10. Safety and Feasibility of Transradial Access for Visceral Interventions in Patients with Thrombocytopenia

    Energy Technology Data Exchange (ETDEWEB)

    Titano, J. J., E-mail: joseph.titano@mountsinai.org; Biederman, D. M., E-mail: derek.biederman@mountsinai.org; Marinelli, B. S., E-mail: brett.marinelli@exchange.mssm.edu; Patel, R. S., E-mail: rahul.patel@mountsinai.org; Kim, E., E-mail: edward.kim@mountsinai.org; Tabori, N. E., E-mail: nora.tabori@mountsinai.org; Nowakowski, F. S., E-mail: scott.nowakowski@mountsinai.org; Lookstein, R. A., E-mail: robert.lookstein@mountsinai.org; Fischman, A. M., E-mail: aaron.fischman@mountsinai.org [Icahn School of Medicine at Mount Sinai, Department of Interventional Radiology (United States)

    2016-05-15

    PurposeTransradial access (TRA) has shown lower morbidity and decreased bleeding complications compared to transfemoral access. This study evaluates the safety and feasibility of TRA in thrombocytopenic patients undergoing visceral interventions.Methods and MaterialsPatients who underwent visceral interventions via the radial artery with platelet count less than or equal to 50,000/µL were included in the study. Outcome variables included technical success, access site, bleeding, transfusion, and neurological complications.ResultsFrom July 1, 2012, to May 31, 2015, a total of 1353 peripheral interventions via TRA were performed, of which 85 procedures were performed in 64 patients (mean age 62.2 years) with a platelet count <50,000/µL (median 39,000/µL). Interventions included chemoembolization (n = 46), selective internal radiation therapy (n = 30), and visceral embolization (n = 9). Technical success was 97.6 % with two cases of severe vessel spasm requiring ipsilateral femoral crossover. There was no major access site, bleeding, or neurological adverse events at 30 days. Minor access site hematomas occurred in five cases (5.9 %) and were treated conservatively in all cases. Pre-procedural platelet transfusions were administered in 23 (27.1 %) cases. There was no statistically significant difference in access site or bleeding complications between the transfused and nontransfused groups.ConclusionsTransradial visceral interventions in patients with thrombocytopenia are both feasible and safe, possibly without the need for platelet transfusions.

  11. Safety and feasibility of the robotic platform in the management of surgical sequelae of chronic pancreatitis.

    Science.gov (United States)

    Hamad, Ahmad; Zenati, Mazen S; Nguyen, Trang K; Hogg, Melissa E; Zeh, Herbert J; Zureikat, Amer H

    2018-02-01

    The application of minimally invasive surgery to chronic pancreatitis (CP) procedures is uncommon. Our objective was to report the safety and feasibility of the robotic approach in the treatment of surgical sequelae of CP, and provide insights into the technique, tricks, and pitfalls associated with the application of robotics to this challenging disease entity. A retrospective review of a prospectively maintained database of patients undergoing robotic-assisted resections and/or drainage procedures for CP at the University of Pittsburgh between May 2009 and January 2017 was performed. A video of a robotic Frey procedure is also shown. Of 812 robotic pancreatic resections and reconstructions 39 were for CP indications. These included 11 total pancreatectomies [with and without auto islet transplantation], 8 Puestow procedures, 4 Frey procedures, 6 pancreaticoduodenectomies, and 10 distal pancreatectomies. Median age was 49, and 41% of the patients were female. The most common etiology for CP was idiopathic pancreatitis (n = 16, 46%). Median operative time was 324 min with a median estimated blood loss of 250 ml. None of the patients required conversion to laparotomy. A Clavien III-IV complication rate was experienced by 5 (13%) patients, including one reoperation. Excluding the eleven patients who underwent TP, rate of clinically relevant postoperative pancreatic fistula was 7% (Grade B = 2, Grade C = 0). No 30 or 90 day mortalities were recorded. The median length of hospital stay was 7 days. Use of the robotic platform is safe and feasible when tackling complex pancreatic resections for sequelae of chronic pancreatitis.

  12. Safety and Feasibility of Using the Second-Generation Pillcam Colon Capsule to Assess Active Colonic Crohn's Disease

    NARCIS (Netherlands)

    D'Haens, Geert; Löwenberg, Mark; Samaan, Mark A.; Franchimont, Denis; Ponsioen, Cyriel; van den Brink, Gijs R.; Fockens, Paul; Bossuyt, Peter; Amininejad, Leila; Rajamannar, Gopalan; Lensink, Elsemieke M.; van Gossum, Andre M.

    2015-01-01

    The second-generation Pillcam Colon Capsule Endoscope (PCCE-2; Given Imaging Ltd, Yoqneam, Israel) is an ingestible capsule for visualization of the colon. We performed a multicenter pilot study to assess its safety and feasibility in evaluating the severity of Crohn's disease (CD). In a prospective

  13. Advanced Supercritical Carbon Dioxide Brayton Cycle Development

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Mark [Univ. of Wisconsin, Madison, WI (United States); Sienicki, James [Argonne National Lab. (ANL), Argonne, IL (United States); Moisseytsev, Anton [Argonne National Lab. (ANL), Argonne, IL (United States); Nellis, Gregory [Univ. of Wisconsin, Madison, WI (United States); Klein, Sanford [Univ. of Wisconsin, Madison, WI (United States)

    2015-10-21

    -through labyrinth seals was proposed. A stepped labyrinth seal, which mimics the behavior of the labyrinth seal used in the Sandia National Laboratory (SNL) S-CO2 Brayton cycle, was also tested in the experiment along with simulations performed. The rest of this study demonstrates the difference of valves' behavior under supercritical fluid and normal fluid conditions. A small-scale valve was tested in the experiment facility using S-CO2. Different percentages of opening valves were tested, and the measured mass flow rate agreed with simulation predictions. Two transients from a real S-CO2 Brayton cycle design provided the data for valve selection. The selected valve was studied using numerical simulation, as experimental data is not available.

  14. Feasibility and Safety Assessment for Advanced Reactor Concepts Using Vented Fuel

    International Nuclear Information System (INIS)

    Klein, Andrew; Lenhof, Renae; Deason, Wesley; Harter, Jackson

    2015-01-01

    Recent interest in fast reactor technology has led to renewed analysis of past reactor concepts such as Gas Fast Reactors and Sodium Fast Reactors. In an effort to make these reactors more economic, the fuel is required to stay in the reactor for extended periods of time; the longer the fuel stays within the core, the more fertile material is converted into usable fissile material. However, as burnup of the fuel-rod increases, so does the internal pressure buildup due to gaseous fission products. In order to reach the 30 year lifetime requirements of some reactor designs, the fuel pins must have a vented-type design to allow the buildup of fission products to escape. The present work aims to progress the understanding of the feasibility and safety issues related to gas reactors that incorporate vented fuel. The work was separated into three different work-scopes: 1. Quantitatively determine fission gas release from uranium carbide in a representative helium cooled fast reactor; 2. Model the fission gas behavior, transport, and collection in a Fission Product Vent System; and, 3. Perform a safety analysis of the Fission Product Vent System. Each task relied on results from the previous task, culminating in a limited scope Probabilistic Risk Assessment (PRA) of the Fission Product Vent System. Within each task, many key parameters lack the fidelity needed for comprehensive or accurate analysis. In the process of completing each task, the data or methods that were lacking were identified and compiled in a Gap Analysis included at the end of the report.

  15. Efficacy, Safety, and Feasibility of the Morphine Microdose Method in Community-Based Clinics.

    Science.gov (United States)

    Wilkes, Denise M; Orillosa, Susan J; Hustak, Erik C; Williams, Courtney G; Doulatram, Gulshan R; Solanki, Daneshvari R; Garcia, Eduardo A; Huang, Li-Yen M

    2017-06-13

    The goal of this study was to assess the success of the morphine microdose method in a community pain clinic setting by monitoring follow-up frequency, dose escalation, and monotherapy/polytherapy ratio. The morphine microdose method involves a pretrial reduction or elimination of systemic opioids followed by a period of abstinence. Intrathecal (IT) morphine is then started at doses of less than 0.2 mg per day. Systemic opioid abstinence is then continued after pump implant and IT morphine monotherapy. Retrospective review of medical records. Private and academic pain clinic practices. Chronic noncancer pain patients. We reviewed the charts of 60 patients who had completed a microdose regimen and had an IT pump implanted between June 11, 2008, and October 11, 2014. During IT therapy, dose change over time, pain scores, side effects, max dose, and duration were recorded. The majority of patients (35/60, 58%) were successfully managed solely on morphine microdose monotherapy. These patients did not require additional oral therapy. There was a significant reduction in mean pain scores, from 7.4 ± 0.32 before microdose therapy to 4.8 ± 0.3 after microdose therapy. Microdose therapy achieved analgesia, improved safety, and avoided systemic side effects. The safety of IT therapy was increased by using a lower concentration (2 mg/mL) and lower daily doses (microdose therapy was feasible, safe, and cost-effective in the outpatient setting. 2017 American Academy of Pain Medicine. This work is written by US Government employees and is in the public domain in the US.

  16. Feasibility and Safety Assessment for Advanced Reactor Concepts Using Vented Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Klein, Andrew [Oregon State Univ., Corvallis, OR (United States). Nuclear Engineering and Radiation Health Physics; Matthews, Topher [Oregon State Univ., Corvallis, OR (United States); Lenhof, Renae [Oregon State Univ., Corvallis, OR (United States); Deason, Wesley [Oregon State Univ., Corvallis, OR (United States); Harter, Jackson [Oregon State Univ., Corvallis, OR (United States)

    2015-01-16

    Recent interest in fast reactor technology has led to renewed analysis of past reactor concepts such as Gas Fast Reactors and Sodium Fast Reactors. In an effort to make these reactors more economic, the fuel is required to stay in the reactor for extended periods of time; the longer the fuel stays within the core, the more fertile material is converted into usable fissile material. However, as burnup of the fuel-rod increases, so does the internal pressure buildup due to gaseous fission products. In order to reach the 30 year lifetime requirements of some reactor designs, the fuel pins must have a vented-type design to allow the buildup of fission products to escape. The present work aims to progress the understanding of the feasibility and safety issues related to gas reactors that incorporate vented fuel. The work was separated into three different work-scopes: 1. Quantitatively determine fission gas release from uranium carbide in a representative helium cooled fast reactor; 2. Model the fission gas behavior, transport, and collection in a Fission Product Vent System; and, 3. Perform a safety analysis of the Fission Product Vent System. Each task relied on results from the previous task, culminating in a limited scope Probabilistic Risk Assessment (PRA) of the Fission Product Vent System. Within each task, many key parameters lack the fidelity needed for comprehensive or accurate analysis. In the process of completing each task, the data or methods that were lacking were identified and compiled in a Gap Analysis included at the end of the report.

  17. Safety and feasibility of liver resection with continued antiplatelet therapy using aspirin.

    Science.gov (United States)

    Monden, Kazuteru; Sadamori, Hiroshi; Hioki, Masayoshi; Ohno, Satoshi; Saneto, Hiromi; Ueki, Toru; Yabushita, Kazuhisa; Ono, Kazumi; Sakaguchi, Kousaku; Takakura, Norihisa

    2017-07-01

    Aspirin is widely used for the secondary prevention of ischemic stroke and cardiovascular disease. Perioperative aspirin may decrease thrombotic morbidity, but may also increase hemorrhagic morbidity. In particular, liver resection carries risks of bleeding, leading to higher risks of hemorrhagic morbidity. Our institution has continued aspirin therapy perioperatively in patients undergoing liver resection. This study examined the safety and feasibility of liver resection while continuing aspirin. We retrospectively evaluated 378 patients who underwent liver resection between January 2010 and January 2016. Patients were grouped according to preoperative aspirin prescription: patients with aspirin therapy (aspirin users, n = 31); and patients without use of aspirin (aspirin non-users, n = 347). Aspirin users were significantly older (P aspirin users than among aspirin non-users, no significant difference was identified. No postoperative hemorrhage was seen among aspirin users. Liver resection can be safely performed while continuing aspirin therapy without increasing hemorrhagic morbidity. Our results suggest that interruption of aspirin therapy is unnecessary for patients undergoing liver resection. © 2017 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  18. da Vinci robot-assisted keyhole neurosurgery: a cadaver study on feasibility and safety.

    Science.gov (United States)

    Marcus, Hani J; Hughes-Hallett, Archie; Cundy, Thomas P; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar

    2015-04-01

    The goal of this cadaver study was to evaluate the feasibility and safety of da Vinci robot-assisted keyhole neurosurgery. Several keyhole craniotomies were fashioned including supraorbital subfrontal, retrosigmoid and supracerebellar infratentorial. In each case, a simple durotomy was performed, and the flap was retracted. The da Vinci surgical system was then used to perform arachnoid dissection towards the deep-seated intracranial cisterns. It was not possible to simultaneously pass the 12-mm endoscope and instruments through the keyhole craniotomy in any of the approaches performed, limiting visualization. The articulated instruments provided greater dexterity than existing tools, but the instrument arms could not be placed in parallel through the keyhole craniotomy and, therefore, could not be advanced to the deep cisterns without significant clashing. The da Vinci console offered considerable ergonomic advantages over the existing operating room arrangement, allowing the operating surgeon to remain non-sterile and seated comfortably throughout the procedure. However, the lack of haptic feedback was a notable limitation. In conclusion, while robotic platforms have the potential to greatly enhance the performance of transcranial approaches, there is strong justification for research into next-generation robots, better suited to keyhole neurosurgery.

  19. Feasibility and safety of endoscopic submucosal dissection for lower rectal tumors with hemorrhoids.

    Science.gov (United States)

    Tanaka, Shinwa; Toyonaga, Takashi; Morita, Yoshinori; Hoshi, Namiko; Ishida, Tsukasa; Ohara, Yoshiko; Yoshizaki, Tetsuya; Kawara, Fumiaki; Umegaki, Eiji; Azuma, Takeshi

    2016-07-21

    To evaluate the feasibility and safety of endoscopic submucosal dissection (ESD) for lower rectal lesions with hemorrhoids. The outcome of ESD for 23 lesions with hemorrhoids (hemorrhoid group) was compared with that of 48 lesions without hemorrhoids extending to the dentate line (non-hemorrhoid group) during the same study period. Median operation times (ranges) in the hemorrhoid and non-hemorrhoid groups were 121 (51-390) and 130 (28-540) min. The en bloc resection rate and the curative resection rate in the hemorrhoid group were 96% and 83%, and they were 100% and 90% in the non-hemorrhoid group, respectively. In terms of adverse events, perforation and postoperative bleeding did not occur in both groups. In terms of the clinical course of hemorrhoids after ESD, the rate of complete recovery of hemorrhoids after ESD in lesions with resection of more than 90% was significantly higher than that in lesions with resection of less than 90%. ESD on lower rectal lesions with hemorrhoids could be performed safely, similarly to that on rectal lesions extending to the dentate line without hemorrhoids. In addition, all hemorrhoids after ESD improved to various degrees, depending on the resection range.

  20. Cervical cancer prevention: safety, acceptability, and feasibility of a single-visit approach in Accra, Ghana.

    Science.gov (United States)

    Blumenthal, Paul D; Gaffikin, Lynne; Deganus, Sylvia; Lewis, Robbyn; Emerson, Mark; Adadevoh, Sydney

    2007-04-01

    The purpose of this study was to assess the safety and acceptability of a single-visit approach to cervical cancer prevention combining visual inspection of the cervix with acetic acid wash (VIA) and cryotherapy. The study was observational. Nine clinicians were trained in VIA and cryotherapy. Over 18 months 3665 women were VIA-tested. If positive and eligible, cryotherapy was offered immediately. Treated women were followed-up at 3 months and 1 year. The test-positive rate was 13.2%. Of those eligible, 70.2% and 21% received immediate or delayed treatment, respectively. No major complications were recorded, and 5.6% presented for a perceived problem post-cryotherapy. Among those treated over 90% expressed satisfaction with their experience, and 96% had an indentifiable squamo-columnar junction. Only 2.6% (6/232) were test positive, 1-year posttreatment. A single-visit approach using VIA and cryotherapy proved to be safe, acceptable, and feasible in an urban African setting.

  1. A Comparison of Coolant Options for Brayton Power Conversion Heat Rejection Systems

    International Nuclear Information System (INIS)

    Siamidis, John; Mason, Lee

    2006-01-01

    This paper describes potential heat rejection design concepts for Brayton power conversion systems. Brayton conversion systems are currently under study by NASA for Nuclear Electric Propulsion (NEP) and surface power applications. The Brayton Heat Rejection Subsystem (HRS) must dissipate waste heat generated by the power conversion system due to inefficiencies in the thermal-to-electric conversion process. Sodium potassium (NaK) and H2O are two coolant working fluids that have been investigated in the design of a pumped loop and heat pipe space HRS. In general NaK systems are high temperature (300 to 1000 K) low pressure systems, and H2O systems are low temperature (300 to 600 K) high pressure systems. NaK is an alkali metal with health and safety hazards that require special handling procedures. On the other hand, H2O is a common fluid, with no health hazards and no special handling procedures. This paper compares NaK and H2O for the HRS pumped loop coolant working fluid. A detailed excel analytical model, HRS O pt, was developed to evaluate the various HRS design parameters. It is capable of analyzing NaK or H2O coolant, parallel or series flow configurations, and numerous combinations of other key parameters (heat pipe spacing, diameter and radial flux, radiator facesheet thickness, fluid duct system pressure drop, system rejected power, etc.) of the HRS. This paper compares NaK against water for the HRS coolant working fluid with respect to the relative mass, performance, design and implementation issues between the two fluids

  2. Intravenous recombinant tissue plasminogen activator for acute ischemic stroke: a feasibility and safety study

    Directory of Open Access Journals (Sweden)

    Sadeghi-Hokmabadi E

    2016-10-01

    Full Text Available Elyar Sadeghi-Hokmabadi, Mehdi Farhoudi, Aliakbar Taheraghdam, Mazyar Hashemilar, Daryous Savadi-Osguei, Reza Rikhtegar, Kaveh Mehrvar, Ehsan Sharifipour, Parisa Youhanaee, Reshad Mirnour Neurosciences Research Center, Neurology Department, Tabriz University of Medical Sciences, Tabriz, East Azerbaijan, Iran Background: In developing countries, intravenous thrombolysis (IVT is available at a limited number of centers. This study aimed to assess the feasibility and safety of IVT at Tabriz Imam Reza Hospital. Methods: In a prospective study, over a 55-month period, any patient at the hospital for whom stroke code had been activated was enrolled in the study. Data on demographic characteristics, stroke risk factors, admission blood pressure, blood tests, findings of brain computed tomography (CT scans, time of symtom onset, time of arrival to the emergency department, time of stroke code activation, time of CT scan examination, and the time of recombinant tissue plasminogen activator administration were recorded. National Institutes of Health Stroke Scale assessments were performed before IVT bolus, at 36 hours, at either 7 days or discharge (which ever one was earlier, and at 3-month follow-up. Brain CT scans were done for all patients before and 24 hours after the treatment. Results: Stroke code was activated for 407 patients and IVT was done in 168 patients. The rate of functional independence (modified Rankin Scale [mRS] 0–1 at 3 months was 39.2% (62/158. The mortality rate at day 7 was 6% (10/168. Hemorrhagic transformation was noted in 16 patients (9.5%. Symptomatic intracranial hemorrhage occurred in 5 (3%, all of which were fatal. One case of severe urinary bleeding and one other fatal case of severe angioedema were observed. Conclusion: During the first 4–5 years of administration of IVT in the hospital, it was found to be feasible and safe, but to increase the efficacy, poststroke care should be more organized and a stroke center

  3. Extension of the supercritical carbon dioxide Brayton cycle for application to the Very High Temperature Reactor

    International Nuclear Information System (INIS)

    Moisseytsev, A.; Sienicki, J. J.

    2010-01-01

    An investigation has been carried out of the feasibility of applying the supercritical carbon dioxide (S-CO 2 ) Brayton cycle to the Very High Temperature Reactor (VHTR). Direct application of the standard S-CO 2 recompression cycle to the VHTR was found to be challenging because of the mismatch in the inherent temperature drops across the He and CO 2 sides of the reactor heat exchanger resulting in a relatively low cycle efficiency of 45 % compared to 48 % for a direct helium cycle. Two approaches consisting of either a cascaded cycle arrangement with three separate cascaded S-CO 2 cycles or, alternately, operation of a single S-CO 2 cycle with the minimum pressure below the critical pressure and the minimum temperature above the critical temperature have been identified and shown to successfully enable the S-CO 2 Brayton cycle to be adapted to the VHTR such that the benefits of the higher S-CO 2 cycle efficiency can be realized. For both approaches, S-CO 2 cycle efficiencies in excess of 49 % are calculated. (authors)

  4. Feasibility, safety, acceptability, and functional outcomes of playing Nintendo Wii Fit Plus™ for frail elderly: study protocol for a feasibility trial.

    Science.gov (United States)

    Gomes, Gisele Cristine Vieira; Bacha, Jéssica Maria Ribeiro; do Socorro Simões, Maria; Lin, Sumika Mori; Viveiro, Larissa Alamino Pereira; Varise, Eliana Maria; Filho, Wilson Jacob; Pompeu, José Eduardo

    2017-01-01

    Frailty can be defined as a medical syndrome with multiple causes and contributors, characterized by diminished strength and endurance and reduced physiological function that increases the vulnerability to develop functional dependency and/or death. Studies have shown that the most commonly studied exercise protocol for frail older adults is the multimodal training. Interactive video games (IVGs) involve tasks in virtual environments that combine physical and cognitive demands in an attractive and challenging way. The aim of this study will be to evaluate the feasibility, safety, acceptability, and functional outcomes of playing Nintendo Wii Fit Plus TM (NWFP) for frail older adults. The study is a randomized controlled, parallel group, feasibility trial. Participants will be randomly assigned to the experimental group (EG) and control group (CG). The EG will participate in 14 training sessions, each lasting 50 min, twice a week. In each training session, the participants will play five games, with three attempts at each game. The first attempt will be performed with the assistance of a physical therapist to correct the movements and posture of the patients and subsequent attempts will be performed independently. Scores achieved in the games will be recorded. The participants will be evaluated by a blinded physical therapist at three moments: before and after intervention and 30 days after the end of the intervention (follow-up). We will assess the feasibility, acceptability, safety, and clinical outcomes (postural control, gait, cognition, quality of life, mood, and fear of falling). Due to the deficiencies in multiple systems, studies have shown that multimodal interventions including motor-cognitive stimulation can improve the mobility of frail elderly adults. IVGs, among them the NWFP, are considered as a multimodal motor-cognitive intervention that can potentially improve motor and cognitive functions in the frail elderly. However, there is still no evidence

  5. Systems Analyses of Advanced Brayton Cycles

    Energy Technology Data Exchange (ETDEWEB)

    A.D. Rao; D.J. Francuz; J.D. Maclay; J. Brouwer; A. Verma; M. Li; G.S. Samuelsen

    2008-09-30

    The main objective is to identify and assess advanced improvements to the Brayton Cycle (such as but not limited to firing temperature, pressure ratio, combustion techniques, intercooling, fuel or combustion air augmentation, enhanced blade cooling schemes) that will lead to significant performance improvements in coal based power systems. This assessment is conducted in the context of conceptual design studies (systems studies) that advance state-of-art Brayton cycles and result in coal based efficiencies equivalent to 65% + on natural gas basis (LHV), or approximately an 8% reduction in heat rate of an IGCC plant utilizing the H class steam cooled gas turbine. H class gas turbines are commercially offered by General Electric and Mitsubishi for natural gas based combined cycle applications with 60% efficiency (LHV) and it is expected that such machine will be offered for syngas applications within the next 10 years. The studies are being sufficiently detailed so that third parties will be able to validate portions or all of the studies. The designs and system studies are based on plants for near zero emissions (including CO{sub 2}). Also included in this program is the performance evaluation of other advanced technologies such as advanced compression concepts and the fuel cell based combined cycle. The objective of the fuel cell based combined cycle task is to identify the desired performance characteristics and design basis for a gas turbine that will be integrated with an SOFC in Integrated Gasification Fuel Cell (IGFC) applications. The goal is the conceptualization of near zero emission (including CO{sub 2} capture) integrated gasification power plants producing electricity as the principle product. The capability of such plants to coproduce H{sub 2} is qualitatively addressed. Since a total systems solution is critical to establishing a plant configuration worthy of a comprehensive market interest, a baseline IGCC plant scheme is developed and used to study

  6. Potential impacts of Brayton and Stirling cycle engines

    Science.gov (United States)

    Heft, R. C.

    1980-01-01

    Two engine technologies (Brayton cycle and Stirling cycle) are examined for their potential economic impact and fuel utilization. An economic analysis of the expected response of buyers to the attributes of the alternative engines was performed. Hedonic coefficients for vehicle fuel efficiency, performance and size were estimated for domestic cars based upon historical data. The marketplace value of the fuel efficiency enhancement provided by Brayton or Stirling engines was estimated. Under the assumptions of 10 years for plant conversions and 1990 and 1995 as the introduction data for turbine and Stirling engines respectively, the comparative fuel savings and present value of the future savings in fuel costs were estimated.

  7. Buffer thermal energy storage for a solar Brayton engine

    Science.gov (United States)

    Strumpf, H. J.; Barr, K. P.

    1981-01-01

    A study has been completed on the application of latent-heat buffer thermal energy storage to a point-focusing solar receiver equipped with an air Brayton engine. To aid in the study, a computer program was written for complete transient/stead-state Brayton cycle performance. The results indicated that thermal storage can afford a significant decrease in the number of engine shutdowns as compared to operating without thermal storage. However, the number of shutdowns does not continuously decrease as the storage material weight increases. In fact, there appears to be an optimum weight for minimizing the number of shutdowns.

  8. Office-based esophageal dilation in head and neck cancer: Safety, feasibility, and cost analysis.

    Science.gov (United States)

    Howell, Rebecca J; Schopper, Melissa A; Giliberto, John Paul; Collar, Ryan M; Khosla, Sid M

    2018-02-08

    To review experience, safety, and cost of office-based esophageal dilation in patients with history of head and neck cancer (HNCA). The medical records of patients undergoing esophageal dilation in the office were retrospectively reviewed between August 2015 and May 2017. Patients were given nasal topical anesthesia. Next, a transnasal esophagoscopy (TNE) was performed. If the patient tolerated TNE, we proceeded with esophageal dilation using Seldinger technique with the CRE™ Boston Scientific (Boston Scientific Corp., Marlborough, MA) balloon system. Patients were discharged directly from the outpatient clinic. Forty-seven dilations were performed in 22 patients with an average of 2.1 dilations/patient (range 1-10, standard deviation [SD] ± 2.2). Seventeen patients (77%) were male. The average age was 67 years (range 35-78 years, SD ± 8.5). The most common primary site of cancer was oral cavity/oropharynx (n = 10), followed by larynx (n = 6). All patients (100%) had history of radiation treatment. Four patients were postlaryngectomy. The indication for esophageal dilation was esophageal stricture and progressive dysphagia. All dilations occurred in the proximal esophagus. There were no major complications. Three focal, superficial lacerations occurred. Two patients experienced mild, self-limited epistaxis. One dilation was poorly tolerated due to discomfort. One patient required pain medication postprocedure. Office-based esophageal dilation generated $15,000 less in health system charges compared to traditional operating room dilation on average per episode of care. In patients with history of HNCA and radiation, office-based TNE with esophageal dilation appears safe, well-tolerated, and cost-effective. In a small cohort, the technique has low complication rate and is feasible in an otolaryngology outpatient office setting. 4. Laryngoscope, 2018. © 2018 The American Laryngological, Rhinological and Otological Society, Inc.

  9. Implementation of enhanced recovery programme for laparoscopic distal pancreatectomy: feasibility, safety and cost analysis.

    Science.gov (United States)

    Richardson, John; Di Fabio, Francesco; Clarke, Hannah; Bajalan, Mohammed; Davids, Joe; Abu Hilal, Mohammed

    2015-01-01

    The adoption of laparoscopy for distal pancreatectomy has proven to substantially improve short-term outcomes. Stress response after major surgery can be further minimized within an enhanced recovery programme (ERP). However, data on the potential benefit of an ERP for laparoscopic distal pancreatectomy are still lacking. The aim was to assess the feasibility, safety and cost of ERP for patients undergoing laparoscopic distal pancreatectomy. This is a case-control study from a Tertiary University Hospital. Sixty-six consecutive patients who underwent laparoscopic distal pancreatectomy were analyzed. Twenty-two patients were enrolled for the ERP and compared with previous consecutive 44 patients managed traditionally (1:2 ratio). Operative details, post-operative outcome and cost analysis were compared in the two groups. Patients enrolled in the ERP had similar intraoperative blood loss (median 165 ml vs. 200 ml; p = 0.176), operation time (225 min vs. 210 min; p = 0.633), time to remove naso-gastric tube (1 vs. 1 day; p = 0.081) but significantly shorter time to mobilization (median 1 vs. 2 days; p = 0.0001), start solid diet (2 vs. 3 days; p = 0004), and pass stools (3 vs. 5 days; p = 0.002) compared to the control group. Median length of stay was significantly shorter in the ERP group (3 vs. 6 days; p pancreatectomy with significant earlier return to normal gut function, reduced length of stay and cost saving. Copyright © 2015 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  10. Safety and feasibility of percutaneous vertebroplasty with radioactive {sup 153}Sm PMMA in an animal model

    Energy Technology Data Exchange (ETDEWEB)

    Lu Jun [Department of Radiotherapy, Xijing Hospital, Fourth Military Medical University, 15 West Changle Road, Xi' an 710032, Shaanxi Province (China); Deng Jinglan, E-mail: dengjinglan@gmail.com [Department of Nuclear Medicine, Xijing Hospital, Fourth Military Medical University, 15 West Changle Road, Xi' an 710032, Shaanxi Province (China); Zhao Haitao [Department of Radiology, Xijing Hospital, Fourth Military Medical University, 15 West Changle Road, Xi' an 710032, Shaanxi Province (China); Shi Mei [Department of Radiotherapy, Xijing Hospital, Fourth Military Medical University, 15 West Changle Road, Xi' an 710032, Shaanxi Province (China); Wang Jing [Department of Nuclear Medicine, Xijing Hospital, Fourth Military Medical University, 15 West Changle Road, Xi' an 710032, Shaanxi Province (China); Zhao Lina [Department of Radiotherapy, Xijing Hospital, Fourth Military Medical University, 15 West Changle Road, Xi' an 710032, Shaanxi Province (China)

    2011-05-15

    Purpose: We investigated the safety and feasibility of the combination of samarium-153-ethylenediamine tetramethylene phosphonate ({sup 153}Sm-EDTMP)-incorporated bone cement (BC) with percutaneous vertebroplasty (PVP) in dogs. Methods and materials: {sup 153}Sm-EDTMP-incorporated BC was prepared by combining solid {sup 153}Sm-EDTMP and polymethylmethacrylate (PMMA) immediately before PVP. It was then injected into the vertebrae of four healthy mongrel dogs (two males and two females) by PVP under CT guidance. Each dog was subjected to five PVP sessions at a {sup 153}Sm-EDTMP dose of 30-70 mCi. The suppressive effect of local injection of {sup 153}Sm-EDTMP on the hematopoietic system was evaluated through counting of peripheral blood cells. Distribution of {sup 153}Sm-EDTMP-incorporated BC and the status of tissues adjacent to injected vertebrae were evaluated with SPECT, CT and MRI. Histopathology was carried out to assess the influence of PVP on the vertebra and adjacent tissues at the microscopic level. Results: PVP was done successfully, and all dogs exhibited normal behavior and stable physical signs after procedures. {sup 153}Sm-EDTMP-incorporated BC was concentrated mainly in target vertebrae, and the peripheral blood cells remained within normal range. The spinal cord and tissues around BC did not exhibit signs of injury even when the dosage of {sup 153}Sm-EDTMP increased from 30 mCi to 70 mCi. Conclusion: A dose lower than 70 mCi of {sup 153}Sm is safe when it was injected into vertebrae. {sup 153}Sm-EDTMP-incorporated BC did not influence the effect of PVP. This means might strengthen anti-tumor activity locally for vertebra with osseous metastasis without damaging adjacent tissues.

  11. Safety and feasibility of long-term intravenous sodium nitrite infusion in healthy volunteers.

    Directory of Open Access Journals (Sweden)

    Ryszard M Pluta

    Full Text Available BACKGROUND: Infusion of sodium nitrite could provide sustained therapeutic concentrations of nitric oxide (NO for the treatment of a variety of vascular disorders. The study was developed to determine the safety and feasibility of prolonged sodium nitrite infusion. METHODOLOGY: Healthy volunteers, aged 21 to 60 years old, were candidates for the study performed at the National Institutes of Health (NIH; protocol 05-N-0075 between July 2007 and August 2008. All subjects provided written consent to participate. Twelve subjects (5 males, 7 females; mean age, 38.8±9.2 years (range, 21-56 years were intravenously infused with increasing doses of sodium nitrite for 48 hours (starting dose at 4.2 µg/kg/hr; maximal dose of 533.8 µg/kg/hr. Clinical, physiologic and laboratory data before, during and after infusion were analyzed. FINDINGS: The maximal tolerated dose for intravenous infusion of sodium nitrite was 267 µg/kg/hr. Dose limiting toxicity occurred at 446 µg/kg/hr. Toxicity included a transient asymptomatic decrease of mean arterial blood pressure (more than 15 mmHg and/or an asymptomatic increase of methemoglobin level above 5%. Nitrite, nitrate, S-nitrosothiols concentrations in plasma and whole blood increased in all subjects and returned to preinfusion baseline values within 12 hours after cessation of the infusion. The mean half-life of nitrite estimated at maximal tolerated dose was 45.3 minutes for plasma and 51.4 minutes for whole blood. CONCLUSION: Sodium nitrite can be safely infused intravenously at defined concentrations for prolonged intervals. These results should be valuable for developing studies to investigate new NO treatment paradigms for a variety of clinical disorders, including cerebral vasospasm after subarachnoid hemorrhage, and ischemia of the heart, liver, kidney and brain, as well as organ transplants, blood-brain barrier modulation and pulmonary hypertension. CLINICAL TRIAL REGISTRATION INFORMATION: http

  12. Closure of tubular patent ductus arteriosus with the Amplatzer Vascular Plug IV: feasibility and safety.

    Science.gov (United States)

    Baruteau, Alban-Elouen; Lambert, Virginie; Riou, Jean-Yves; Angel, Claude-Yves; Belli, Emre; Petit, Jérôme

    2015-01-01

    Closure of tubular patent ductus arteriosus remains a challenging procedure. Anecdotal use of Amplatzer Vascular Plug IV for tubular ductus closure has been reported but feasibility and safety in a consecutive patients' series remain unknown. We performed a monocenter prospective study at the Marie Lannelongue Hospital in Paris, France. From 2009 to 2014, a total of 47 patients (39 infants, 3 children, and 5 adults) underwent ductus closure with the Plug IV. Ductus morphology was a type E in 34 (72.3%) patients and a type C in 13 (27.7%) patients. Ductus closure occurred in 39 (83.0%) infants at a median age of seven months (range: 3-23 months) and a median weight of 6.9 kg (range: 4.1-17.0 kg). A past history of prematurity and very low birth weight was found in 33 (70.2%) of them. Twelve (25.5%) patients had pulmonary hypertension. Mean Plug IV diameter was 1.9 ± 0.1 mm larger than the mean maximal ductus diameter. Early complete closure of the ductus was obtained in all patients. Early migration of an undersized Plug IV occurred in one (2.1%) patient and was suitable for percutaneous device retrieval. After a mean follow-up of 3.4 ± 1.4 years, all patients are alive and asymptomatic, no late complication occurred. Transcatheter closure of tubular ductus with the Amplatzer Vascular Plug IV can be safe and effective, with a 100% early occlusion rate. This device, suitable for a 4F sheath, is a new alternative for tubular ductus closure in low-body-weight infants. © The Author(s) 2014.

  13. Program plan for the Brayton Isotope Power System. Phase I. Design, fabrication and test of the Brayton Isotope Power System

    International Nuclear Information System (INIS)

    1975-01-01

    Phase I of an overall program for the development of a 500 to 2000 W(e) (EOM), 7-y life, power system for space vehicles is discussed. The system uses a closed Brayton dynamic system to convert energy from an isotope heat source at a net efficiency greater than 25 percent. This first phase, a 35-month effort, is for the conceptual design of a 1300 W(e), 450 lb flight system and the design, fabrication, and test of a ground demonstration system. The flight system will use, for the baseline design, two of the multihundred-watt (MHW) heat sources being developed. The Ground Demonstration System will simulate, as closely as possible, the Brayton Isotope Power Flight System and will utilize components and technology being developed for the Mini-Brayton rotating unit, recuperator and heat source assembly, respectively. The Ground Demonstration System includes a performance test and a 1000-h endurance test

  14. Use of Active-Play Video Games to Enhance Aerobic Fitness in Schizophrenia: Feasibility, Safety, and Adherence.

    Science.gov (United States)

    Kimhy, David; Khan, Samira; Ayanrouh, Lindsey; Chang, Rachel W; Hansen, Marie C; Lister, Amanda; Ballon, Jacob S; Vakhrusheva, Julia; Armstrong, Hilary F; Bartels, Matthew N; Sloan, Richard P

    2016-02-01

    Active-play video games have been used to enhance aerobic fitness in various clinical populations, but their use among individuals with schizophrenia has been limited. Feasibility, acceptability, safety, and adherence data were obtained for use of aerobic exercise (AE) equipment by 16 individuals with schizophrenia during a 12-week AE program consisting of three one-hour exercise sessions per week. Equipment included exercise video games for Xbox 360 with Kinect motion sensing devices and traditional exercise equipment. Most participants (81%) completed the training, attending an average of 79% of sessions. The proportion of time spent playing Xbox (39%) exceeded time spent on any other type of equipment. When using Xbox, participants played 2.24±1.59 games per session and reported high acceptability and enjoyment ratings, with no adverse events. Measures of feasibility, acceptability, adherence, and safety support the integration of active-play video games into AE training for people with schizophrenia.

  15. On the reversed Brayton cycle with high speed machinery

    Energy Technology Data Exchange (ETDEWEB)

    Backman, J.

    1996-12-31

    This work was carried out in the laboratory of Fluid Dynamics, at Lappeenranta University of Technology during the years 1991-1996. The research was a part of larger high speed technology development research. First, there was the idea of making high speed machinery applications with the Brayton cycle. There was a clear need to deepen the knowledge of the cycle itself and to make a new approach in the field of the research. Also, the removal of water from the humid air seemed very interesting. The goal of this work was to study methods of designing high speed machinery for the reversed Brayton cycle, from theoretical principles to practical applications. The reversed Brayton cycle can be employed as an air dryer, a heat pump or a refrigerating machine. In this research the use of humid air as a working fluid has an environmental advantage, as well. A new calculation method for the Brayton cycle is developed. In this method especially the expansion process in the turbine is important because of the condensation of the water vapour in the humid air. This physical phenomena can have significant effects on the level of performance of the application. Also, the influence of calculating the process with actual, achievable process equipment efficiencies is essential for the development of future machinery. The above theoretical calculations are confirmed with two different laboratory prototypes. (53 refs.)

  16. On the reversed Brayton cycle with high speed machinery

    Energy Technology Data Exchange (ETDEWEB)

    Backman, J

    1997-12-31

    This work was carried out in the laboratory of Fluid Dynamics, at Lappeenranta University of Technology during the years 1991-1996. The research was a part of larger high speed technology development research. First, there was the idea of making high speed machinery applications with the Brayton cycle. There was a clear need to deepen the knowledge of the cycle itself and to make a new approach in the field of the research. Also, the removal of water from the humid air seemed very interesting. The goal of this work was to study methods of designing high speed machinery for the reversed Brayton cycle, from theoretical principles to practical applications. The reversed Brayton cycle can be employed as an air dryer, a heat pump or a refrigerating machine. In this research the use of humid air as a working fluid has an environmental advantage, as well. A new calculation method for the Brayton cycle is developed. In this method especially the expansion process in the turbine is important because of the condensation of the water vapour in the humid air. This physical phenomena can have significant effects on the level of performance of the application. Also, the influence of calculating the process with actual, achievable process equipment efficiencies is essential for the development of future machinery. The above theoretical calculations are confirmed with two different laboratory prototypes. (53 refs.)

  17. Small particle bed reactors: Sensitivity to Brayton cycle parameters

    Science.gov (United States)

    Coiner, John R.; Short, Barry J.

    Relatively simple particle bed reactor (PBR) algorithms were developed for optimizing low power closed Brayton cycle (CBC) systems. These algorithms allow the system designer to understand the relationship among key system parameters as well as the sensitivity of the PBR size and mass (a major system component) to variations in these parameters. Thus, system optimization can be achieved.

  18. Laparoscopic cholecystectomy in acute gallstone pancreatitis in index hospital admission: feasibility and safety.

    Science.gov (United States)

    Sangrasi, Ahmed Khan; Syed, Bm; Memon, Amir Iqbal; Laghari, Abdul Aziz; Talpur, K Altaf Hussain; Qureshi, Jawaid Naeem

    2014-05-01

    Acute gallstone pancreatitis is quite common throughout the globe. Conventionally definitive cholecystectomy has been delayed in index hospital admission. Since the last decade timing of cholecystectomy is gradually shifting towards the earlier phase of disease and currently gallstone pancreatitis is being evaluated as a further indication for laparoscopic cholecystectomy. There is also great concern regarding compliance of patients for definitive surgery due to poverty, ignorance and illiteracy in developing countries. The aim of this study was to assess the feasibility and safety of laparoscopic cholecystectomy as a definitive treatment in patients with mild and resolving gall stone pancreatitis. This was a prospective study from July 2009 to June 2012. Patients were diagnosed by clinical examination, biochemical tests, ultrasonography and contrast enhanced CT. Patients with mild form of the disease (Ranson Score ≤3) and who showed clinical improvement were offered laparoscopic cholecystectomy in index hospital admission. Those who were unfit for surgery were referred for endoscopic sphincterotomy. Common bile duct stones were excluded preoperatively. A total of 38 patients were admitted with acute gallstone pancreatitis in the study period. The mean age of patients was 46.3 years with male to female ratio of 11/27. 22 (57.8%) patients were selected for laparoscopic cholecystectomy and procedure was completed successfully. Ten (26.3%) patients were referred for ERCP and endoscopic sphincterotomy and 11 (28.9%) were managed by conservative treatment and went without any definitive treatment. Mean duration of time from onset of symptoms and laparoscopic cholecystectomy was 7 days (range 4-10). Mean duration of operative time was 45 minutes and hospital stay was 7 days. There was no operative mortality. No major intra-operative or post-operative complication was recorded. two patients (9%) had minor complications. Laparoscopic cholecystectomy can be safely

  19. Feasibility and safety of same-day discharge after laparoscopic radical hysterectomy for cervix cancer.

    Science.gov (United States)

    Philp, Lauren; Covens, Allan; Vicus, Danielle; Kupets, Rachel; Pulman, Katherine; Gien, Lilian T

    2017-12-01

    To evaluate the safety and feasibility of same day-discharge (SDD) after laparoscopic radical hysterectomy for cervix cancer by determining complication rates and factors associated with post-operative admission. In this retrospective cohort study, patients undergoing laparoscopic radical hysterectomy for cervix cancer at a single institution from January 2006 to November 2015 were identified. Admitted patients were compared to same-day discharge patients. Rates of post-operative complications and readmission were analyzed and regression analysis used to determine factors associated with admission. 119 patients were identified. 75 (63%) were SDD patients (mean stay 156.7±50.2min) and 44 (37%) were admitted patients (mean stay 1.2±0.6days). Ten (13%) SDD patients sought medical attention within 30days post-operatively vs. nine (20%) admitted patients (p=0.17). Reasons SDD patients sought attention included pain (n=1), wound concerns (n=2), vaginal bleeding (n=2), DVT/VTE (n=1), fever (n=2) and fistula (n=2). All patients developed symptoms and presented between 5 and 13days post-operatively thus no complications could have been detected or prevented through initial admission. Four SDD patients were readmitted within 30days of surgery (p=0.25), two required re-operation (p=0.16). Admitted patients were older (p=0.049), had longer operations (p=0.02), increased blood loss (p=0.0004), increased intra-operative complications (p=0.001), surgery later in the day (p=0.004) and before April 2010 (p=0.001). On multivariate analysis, older age (OR1.05, p=0.03), surgery later in the day (OR 7.22, p=0.002) and presence of an intra-operative complication (OR 10.25, p=0.02) were significantly associated with admission. Same-day discharge after laparoscopic radical hysterectomy for cervix cancer is safe, with a low risk of post-operative morbidity and hospital readmission. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. The closed Brayton cycle: An energy conversion system for near-term military space missions

    Science.gov (United States)

    Davis, Keith A.

    The Particle Bed Reactor (PBR)-closed Brayton cycle (CBC) provides a 5 to 30 kWe class nuclear power system for surveillance and communication missions during the 1990s and will scale to 100 kWe and beyond for other space missions. The PBR-CBC is technically feasible and within the existing state of the art. The PBR-CBC system is flexible, scaleable, and offers development economy. The ability to operate over a wide power range promotes commonality between missions with similar but not identical power spectra. The PBR-CBC system mass is very competitive with rival nuclear dynamic and static power conversion and systems. The PBR-CBC provides growth potential for the future with even lower specific masses.

  1. Carbon-Carbon Composites as Recuperator Materials for Direct Gas Brayton Systems

    International Nuclear Information System (INIS)

    RA Wolf

    2006-01-01

    Of the numerous energy conversion options available for a space nuclear power plant (SNPP), one that shows promise in attaining reliable operation and high efficiency is the direct gas Brayton (GB) system. In order to increase efficiency, the GB system incorporates a recuperator that accounts for nearly half the weight of the energy conversion system (ECS). Therefore, development of a recuperator that is lighter and provides better performance than current heat exchangers could prove to be advantageous. The feasibility of a carbon-carbon (C/C) composite recuperator core has been assessed and a mass savings of 60% and volume penalty of 20% were projected. The excellent thermal properties, high-temperature capabilities, and low density of carbon-carbon materials make them attractive in the GB system, but development issues such as material compatibility with other structural materials in the system, such as refractory metals and superalloys, permeability, corrosion, joining, and fabrication must be addressed

  2. Carbon-Carbon Composites as Recuperator Material for Direct Gas Brayton Systems

    Energy Technology Data Exchange (ETDEWEB)

    RA Wolf

    2006-07-19

    Of the numerous energy conversion options available for a space nuclear power plant (SNPP), one that shows promise in attaining reliable operation and high efficiency is the direct gas Brayton (GB) system. In order to increase efficiency, the GB system incorporates a recuperator that accounts for nearly half the weight of the energy conversion system (ECS). Therefore, development of a recuperator that is lighter and provides better performance than current heat exchangers could prove to be advantageous. The feasibility of a carbon-carbon (C/C) composite recuperator core has been assessed and a mass savings of 60% and volume penalty of 20% were projected. The excellent thermal properties, high-temperature capabilities, and low density of carbon-carbon materials make them attractive in the GB system, but development issues such as material compatibility with other structural materials in the system, such as refractory metals and superalloys, permeability, corrosion, joining, and fabrication must be addressed.

  3. Environmental, Safety, and Health Plan for the remedial investigation/feasibility study at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1993-05-01

    This Environmental, Safety, and Health (ES ampersand H) Plan presents the concepts and methodologies to be followed during the remedial investigation/feasibility study (RI/FS) for Oak Ridge National Laboratory (ORNL) to protect the health and safety of employees, the public, and the environment. This ES ampersand H Plan acts as a management extension for ORNL and Martin Marietta Energy Systems, Inc. (Energy Systems) to direct and control implementation of the project ES ampersand H program. The subsections that follow describe the program philosophy, requirements, quality assurance measures, and methods for applying the ES ampersand H program to individual waste area grouping (WAG) remedial investigations. Hazardous work permits (HWPs) will be used to provide task-specific health and safety requirements

  4. Patient-led training on patient safety: a pilot study to test the feasibility and acceptability of an educational intervention.

    Science.gov (United States)

    Jha, V; Winterbottom, A; Symons, J; Thompson, Z; Quinton, N; Corrado, O J; Melville, C; Watt, I; Torgerson, D; Wright, J

    2013-09-01

    Training in patient safety is an important element of medical education. Most educational interventions on patient safety training adopt a 'health-professional lens' with limited consideration on the impact of safety lapses on the patient and their families and little or no involvement of patients in the design or delivery of the training. This paper describes a pilot study to test the feasibility and acceptability of implementing a patient-led educational intervention to facilitate safety training amongst newly qualified doctors. Patients and/or carers who had experienced harm during their care shared narratives of their stories with trainees; this was followed by a focused discussion on patient safety issues exploring the causes and consequences of safety incidents and lessons to be learned from these. The intervention, which will be further tested in an NIHR-funded randomised controlled trial (RCT), was successfully implemented into an existing training programme and found acceptance amongst the patients and trainees. The pilot study proved to be a useful step in refining the intervention for the RCT including identifying appropriate outcome measures and highlighting organisational issues.

  5. Continuous Postoperative Pericardial Flushing: A Pilot Study on Safety, Feasibility, and Effect on Blood Loss

    Directory of Open Access Journals (Sweden)

    Johan S.J. Manshanden

    2015-09-01

    Conclusions: CPPF after cardiac surgery was found to be safe and feasible in this experimental setting. The clinically relevant effect on blood loss needs to be confirmed in a randomized clinical trial.

  6. Feasibility, safety and outcomes of playing Kinect Adventures!™ for people with Parkinson's disease: a pilot study.

    Science.gov (United States)

    Pompeu, J E; Arduini, L A; Botelho, A R; Fonseca, M B F; Pompeu, S M A A; Torriani-Pasin, C; Deutsch, J E

    2014-06-01

    To assess the feasibility, safety and outcomes of playing Microsoft Kinect Adventures™ for people with Parkinson's disease in order to guide the design of a randomised clinical trial. Single-group, blinded trial. Rehabilitation Center of São Camilo University, Brazil. Seven patients (six males, one female) with Parkinson's disease (Hoehn and Yahr Stages 2 and 3). Fourteen 60-minute sessions, three times per week, playing four games of Kinect Adventures! The feasibility and safety outcomes were patients' game performance and adverse events, respectively. The clinical outcomes were the 6-minute walk test, Balance Evaluation System Test, Dynamic Gait Index and Parkinson's Disease Questionnaire (PDQ-39). Patients' scores for the four games showed improvement. The mean [standard deviation (SD)] scores in the first and last sessions of the Space Pop game were 151 (36) and 198 (29), respectively [mean (SD) difference 47 (7), 95% confidence interval 15 to 79]. There were no adverse events. Improvements were also seen in the 6-minute walk test, Balance Evaluation System Test, Dynamic Gait Index and PDQ-39 following training. Kinect-based training was safe and feasible for people with Parkinson's disease (Hoehn and Yahr Stages 2 and 3). Patients improved their scores for all four games. No serious adverse events occurred during training with Kinect Adventures!, which promoted improvement in activities (balance and gait), body functions (cardiopulmonary aptitude) and participation (quality of life). Copyright © 2013 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  7. CRASH - Community Road Accident System Homepage : feasibility study on a European Road Safety Information System, financially supported by the European Commission.

    NARCIS (Netherlands)

    Brouwer, M. Poppe, F. Blokpoel, A. & Kars, V.

    2000-01-01

    This report is the result of a feasibility study, financially supported by the European Commission. The study investigated the possibilities for the development and maintenance of a European Road Safety Information System with relevant and internationally comparable information. Recommendations on

  8. What can nanosafety learn from drug development? The feasibility of “safety by design”

    DEFF Research Database (Denmark)

    Hjorth, Rune; van Hove, Lilian; Wickson, Fern

    2017-01-01

    Safety by design” (SbD) is an intuitively appealing concept that is on the rise within nanotoxicology and nanosafety research, as well as within nanotechnology research policy. It leans on principles established within drug discovery and development (DDD) and seeks to address safety early, as well...... as throughout product development. However, it remains unclear what the concept of SbD exactly entails for engineered nanomaterials (ENMs) or how it is envisioned to be implemented. Here, we review the concept as it is emerging in European research and compare its resemblance with the safety testing...

  9. The feasibility, safety and cost of infiltration anaesthesia for hernia repair. Hvidovre Hospital Hernia Group

    DEFF Research Database (Denmark)

    Callesen, T; Bech, K; Kehlet, H

    1998-01-01

    Data from 400 consecutive elective ambulatory operations for inguinal hernia under unmonitored local anaesthesia with limited pre-operative testing were prospectively obtained by the use of standardised files and questionnaires to assess the feasibility, patient satisfaction and potential cost re...

  10. Thermodynamic Analysis of an Irreversible Maisotsenko Reciprocating Brayton Cycle

    Directory of Open Access Journals (Sweden)

    Fuli Zhu

    2018-03-01

    Full Text Available An irreversible Maisotsenko reciprocating Brayton cycle (MRBC model is established using the finite time thermodynamic (FTT theory and taking the heat transfer loss (HTL, piston friction loss (PFL, and internal irreversible losses (IILs into consideration in this paper. A calculation flowchart of the power output (P and efficiency (η of the cycle is provided, and the effects of the mass flow rate (MFR of the injection of water to the cycle and some other design parameters on the performance of cycle are analyzed by detailed numerical examples. Furthermore, the superiority of irreversible MRBC is verified as the cycle and is compared with the traditional irreversible reciprocating Brayton cycle (RBC. The results can provide certain theoretical guiding significance for the optimal design of practical Maisotsenko reciprocating gas turbine plants.

  11. Rankine-Brayton engine powered solar thermal aircraft

    Science.gov (United States)

    Bennett, Charles L [Livermore, CA

    2009-12-29

    A solar thermal powered aircraft powered by heat energy from the sun. A Rankine-Brayton hybrid cycle heat engine is carried by the aircraft body for producing power for a propulsion mechanism, such as a propeller or other mechanism for enabling sustained free flight. The Rankine-Brayton engine has a thermal battery, preferably containing a lithium-hydride and lithium mixture, operably connected to it so that heat is supplied from the thermal battery to a working fluid. A solar concentrator, such as reflective parabolic trough, is movably connected to an optically transparent section of the aircraft body for receiving and concentrating solar energy from within the aircraft. Concentrated solar energy is collected by a heat collection and transport conduit, and heat transported to the thermal battery. A solar tracker includes a heliostat for determining optimal alignment with the sun, and a drive motor actuating the solar concentrator into optimal alignment with the sun based on a determination by the heliostat.

  12. Rankline-Brayton engine powered solar thermal aircraft

    Science.gov (United States)

    Bennett, Charles L [Livermore, CA

    2012-03-13

    A solar thermal powered aircraft powered by heat energy from the sun. A Rankine-Brayton hybrid cycle heat engine is carried by the aircraft body for producing power for a propulsion mechanism, such as a propeller or other mechanism for enabling sustained free flight. The Rankine-Brayton engine has a thermal battery, preferably containing a lithium-hydride and lithium mixture, operably connected to it so that heat is supplied from the thermal battery to a working fluid. A solar concentrator, such as reflective parabolic trough, is movably connected to an optically transparent section of the aircraft body for receiving and concentrating solar energy from within the aircraft. Concentrated solar energy is collected by a heat collection and transport conduit, and heat transported to the thermal battery. A solar tracker includes a heliostat for determining optimal alignment with the sun, and a drive motor actuating the solar concentrator into optimal alignment with the sun based on a determination by the heliostat.

  13. Buffer thermal energy storage for an air Brayton solar engine

    Science.gov (United States)

    Strumpf, H. J.; Barr, K. P.

    1981-01-01

    The application of latent-heat buffer thermal energy storage to a point-focusing solar receiver equipped with an air Brayton engine was studied. To demonstrate the effect of buffer thermal energy storage on engine operation, a computer program was written which models the recuperator, receiver, and thermal storage device as finite-element thermal masses. Actual operating or predicted performance data are used for all components, including the rotating equipment. Based on insolation input and a specified control scheme, the program predicts the Brayton engine operation, including flows, temperatures, and pressures for the various components, along with the engine output power. An economic parametric study indicates that the economic viability of buffer thermal energy storage is largely a function of the achievable engine life.

  14. Power conversion systems based on Brayton cycles for fusion reactors

    International Nuclear Information System (INIS)

    Linares, J.I.; Herranz, L.E.; Moratilla, B.Y.; Serrano, I.P.

    2011-01-01

    This paper investigates Brayton power cycles for fusion reactors. Two working fluids have been explored: helium in classical configurations and CO 2 in recompression layouts (Feher cycle). Typical recuperator arrangements in both cycles have been strongly constrained by low temperature of some of the energy thermal sources from the reactor. This limitation has been overcome in two ways: with a combined architecture and with dual cycles. Combined architecture couples the Brayton cycle with a Rankine one capable of taking advantage of the thermal energy content of the working fluid after exiting the turbine stage (iso-butane and steam fitted best the conditions of the He and CO 2 cycles, respectively). Dual cycles set a specific Rankine cycle to exploit the lowest quality thermal energy source, allowing usual recuperator arrangements in the Brayton cycle. The results of the analyses indicate that dual cycles could reach thermal efficiencies around 42.8% when using helium, whereas thermal performance might be even better (46.7%), if a combined CO 2 -H 2 O cycle was set.

  15. Supercritical Carbon Dioxide Brayton Cycle Energy Conversion System

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Jae Eun; Kim, S. O.; Seong, S. H.; Eoh, J. H.; Lee, T. H.; Choi, S. K.; Han, J. W.; Bae, S. W

    2007-12-15

    This report contains the description of the S-CO{sub 2} Brayton cycle coupled to KALIMER-600 as an alternative energy conversion system. For system development, a computer code was developed to calculate heat balance of 100% power operation condition. Based on the computer code, the S-CO{sub 2} Brayton cycle energy conversion system was constructed for the KALIMER-600. Using the developed turbomachinery models, the off-design characteristics and the sensitivities of the S-CO{sub 2} turbomachinery were investigated. For the development of PCHE models, a one-dimensional analysis computer code was developed to evaluate the performance of the PCHE. Possible control schemes for power control in the KALIMER-600 S-CO{sub 2} Brayton cycle were investigated by using the MARS code. Simple power reduction and recovery event was selected and analyzed for the transient calculation. For the evaluation of Na/CO{sub 2} boundary failure event, a computer was developed to simulate the complex thermodynamic behaviors coupled with the chemical reaction between liquid sodium and CO{sub 2} gas. The long term behavior of a Na/CO{sub 2} boundary failure event and its consequences which lead to a system pressure transient were evaluated.

  16. Supercritical Carbon Dioxide Brayton Cycle Energy Conversion System

    International Nuclear Information System (INIS)

    Cha, Jae Eun; Kim, S. O.; Seong, S. H.; Eoh, J. H.; Lee, T. H.; Choi, S. K.; Han, J. W.; Bae, S. W.

    2007-12-01

    This report contains the description of the S-CO 2 Brayton cycle coupled to KALIMER-600 as an alternative energy conversion system. For system development, a computer code was developed to calculate heat balance of 100% power operation condition. Based on the computer code, the S-CO 2 Brayton cycle energy conversion system was constructed for the KALIMER-600. Using the developed turbomachinery models, the off-design characteristics and the sensitivities of the S-CO 2 turbomachinery were investigated. For the development of PCHE models, a one-dimensional analysis computer code was developed to evaluate the performance of the PCHE. Possible control schemes for power control in the KALIMER-600 S-CO 2 Brayton cycle were investigated by using the MARS code. Simple power reduction and recovery event was selected and analyzed for the transient calculation. For the evaluation of Na/CO 2 boundary failure event, a computer was developed to simulate the complex thermodynamic behaviors coupled with the chemical reaction between liquid sodium and CO 2 gas. The long term behavior of a Na/CO 2 boundary failure event and its consequences which lead to a system pressure transient were evaluated

  17. Phase Two Feasibility Study for Software Safety Requirements Analysis Using Model Checking

    Science.gov (United States)

    Turgeon, Gregory; Price, Petra

    2010-01-01

    A feasibility study was performed on a representative aerospace system to determine the following: (1) the benefits and limitations to using SCADE , a commercially available tool for model checking, in comparison to using a proprietary tool that was studied previously [1] and (2) metrics for performing the model checking and for assessing the findings. This study was performed independently of the development task by a group unfamiliar with the system, providing a fresh, external perspective free from development bias.

  18. Feasibility, safety, acceptability, and preliminary efficacy of measurement-based care depression treatment for HIV patients in Bamenda, Cameroon.

    Science.gov (United States)

    Pence, Brian W; Gaynes, Bradley N; Atashili, Julius; O'Donnell, Julie K; Kats, Dmitry; Whetten, Kathryn; Njamnshi, Alfred K; Mbu, Tabenyang; Kefie, Charles; Asanji, Shantal; Ndumbe, Peter

    2014-06-01

    Depression affects 18-30 % of HIV-infected patients in Africa and is associated with greater stigma, lower antiretroviral adherence, and faster disease progression. However, the region's health system capacity to effectively identify and treat depression is limited. Task-shifting models may help address this large mental health treatment gap. Measurement-Based Care (MBC) is a task-shifting model in which a Depression Care Manager guides a non-psychiatric (e.g., HIV) provider in prescribing and managing antidepressant treatment. We adapted MBC for depressed HIV-infected patients in Cameroon and completed a pilot study to assess feasibility, safety, acceptability, and preliminary efficacy. We enrolled 55 participants; all started amitriptyline 25-50 mg daily at baseline. By 12 weeks, most remained at 50 mg daily (range 25-125 mg). Median (interquartile range) PHQ-9 depressive severity scores declined from 13 (12-16) (baseline) to 2 (0-3) (week 12); 87 % achieved depression remission (PHQ-9 feasibility, safety, acceptability, and preliminary efficacy in this uncontrolled pilot study. Further research should assess whether MBC could improve adherence and HIV outcomes in this setting.

  19. Feasibility, safety, and efficacy of aerobic training in pretreated patients with metastatic breast cancer: A randomized controlled trial.

    Science.gov (United States)

    Scott, Jessica M; Iyengar, Neil M; Nilsen, Tormod S; Michalski, Meghan; Thomas, Samantha M; Herndon, James; Sasso, John; Yu, Anthony; Chandarlapaty, Sarat; Dang, Chau T; Comen, Elizabeth A; Dickler, Maura N; Peppercorn, Jeffrey M; Jones, Lee W

    2018-04-06

    The investigation of exercise training in metastatic breast cancer has received minimal attention. This study determined the feasibility and safety of aerobic training in metastatic breast cancer. Sixty-five women (age, 21-80 years) with metastatic (stage IV) breast cancer (57% were receiving chemotherapy, and >40% had ≥ 2 lines of prior therapy) were allocated to an aerobic training group (n = 33) or a stretching group (n = 32). Aerobic training consisted of 36 supervised treadmill walking sessions delivered thrice weekly between 55% and 80% of peak oxygen consumption (VO 2peak ) for 12 consecutive weeks. Stretching was matched to aerobic training with respect to location, frequency, duration, and intervention length. The primary endpoint was aerobic training feasibility, which was a priori defined as the lost to follow-up (LTF) rate (aerobic training was LTF, whereas the mean attendance rate was 63% ± 30%. The rates of permanent discontinuation and dose modification were 27% and 49%, respectively. Intention-to-treat analyses indicated improvements in PROs, which favored the attention control group (P values > .05). Per protocol analyses indicated that 14 of 33 patients (42%) receiving aerobic training had acceptable tolerability (relative dose intensity ≥ 70%), and this led to improvements in VO 2peak and functional capacity (P values Aerobic training at the dose and schedule tested is safe but not feasible for a significant proportion of patients with metastatic breast cancer. The acceptable feasibility and promising benefit for select patients warrant further evaluation in a dose-finding phase 1/2 study. Cancer 2018. © 2018 American Cancer Society. © 2018 American Cancer Society.

  20. Current MitraClip experience, safety and feasibility in the Netherlands

    NARCIS (Netherlands)

    Rahhab, Z.; Kortlandt, F. A.; Velu, J. F.; Schurer, R. A. J.; Delgado, V.; Tonino, P.; Boven, A. J.; van den Branden, B. J. L.; Kraaijeveld, A. O.; Voskuil, M.; Hoorntje, J.; van Wely, M. [=Marleen; van Houwelingen, K.; Bleeker, G. B.; Rensing, B.; Kardys, I.; Baan, J.; van der Heyden, J. A. S.; van Mieghem, N. M.

    2017-01-01

    Purpose Data on MitraClip procedural safety and efficacy in the Netherlands are scarce. We aim to provide an overview of the Dutch MitraClip experience. Methods We pooled anonymised demographic and procedural data of 1151 consecutive MitraClip patients, from 13 Dutch hospitals. Data was collected by

  1. Randomized Controlled Study on Safety and Feasibility of Transfusion Trigger Score of Emergency Operations

    Directory of Open Access Journals (Sweden)

    De-Xing Liu

    2015-01-01

    Conclusions: Peri-operative Transfusion Trigger Score-E evaluation scheme is used to guide the application of RBC. There are no differences in the recent prognosis of patients with the traditional transfusion guidelines. This scheme is safe; Compared with doctor experience-based subjective assessment, the scoring scheme was closer to patient physiological needs for transfusion and more reasonable; Utilization rate and the per capita consumption of RBC are obviously declined, which has clinical significance and is feasible. Based on the abovementioned three points, POTTS-E scores scheme is safe, reasonable, and practicable and has the value for carrying out multicenter and large sample clinical researches.

  2. Current MitraClip experience, safety and feasibility in the Netherlands

    OpenAIRE

    Rahhab, Z.; Kortlandt, F.A.; Velu, J.F.; Schurer, R.A.J.; Delgado, V.; Tonino, P.; Boven, A.J. van; Branden, B.J.L. Van den; Kraaijeveld, A.O.; Voskuil, M.; Hoorntje, J.; Wely, M.H. van; Houwelingen, K. van; Bleeker, G.B.; Rensing, B.

    2017-01-01

    PURPOSE: Data on MitraClip procedural safety and efficacy in the Netherlands are scarce. We aim to provide an overview of the Dutch MitraClip experience. METHODS: We pooled anonymised demographic and procedural data of 1151 consecutive MitraClip patients, from 13 Dutch hospitals. Data was collected by product specialists in collaboration with local operators. Effect on mitral regurgitation was intra-procedurally assessed by transoesophageal echocardiography. Technical success and device succe...

  3. A feasibility study on the extended cycle from the point of view of Non-LOCA safety analysis

    International Nuclear Information System (INIS)

    Lee, Chul Sin; Kim, Hee Chul; Kim, Jeong Jin; Baek, Seung Su; Lee, Byung Il; Jeon, Tae Hyun; Lee, Jeong Chan

    1996-06-01

    Extended cycle operation has many advantages as compared with standard cycle operation (12 months) from the viewpoint of operators' exposure to radiation dose, man-power for maintenance and the production of nuclear waste. And it is more economic than the standard cycle operation. If the extended cycle operation is adopted in the CE type nuclear plant, the effective management and enhancement of operation capability could be expected. A feasibility study on the extended cycle operation should be performed. The purpose of this technical report is to perform safety analysis using the design data for Yonggwang Nuclear Plant (YGN) 3 and 4 extended cycle operation and to evaluate qualitatively and quantitatively the safety related design basis events to verify the satisfaction of the safety criteria. Boron dilution and steam line break accidents were found to be most influenced by the change of physics data due to the adaptation of the extended cycle operation. For boron dilution accident, source range monitor ratio of 3.07 for YGN 3 cycle 2 was decreased to 2.92. The 3D reactivity feedback effect due to the local heatup in the vicinity of stuck CEA was credited in the analysis of steam line break. No return-to-power occurred for the steam line break with offsite power available and return-to-power occurred for the steam line break with loss of offsite power. For the steam line break with loss of offsite power, the safety margin was preserved with respect to fuel performance (DNB and LHGR) despite the return-to-power. 6 tabs., 10 figs., 5 refs. (Author) .new

  4. Performance estimates for the Space Station power system Brayton Cycle compressor and turbine

    Science.gov (United States)

    Cummings, Robert L.

    1989-01-01

    The methods which have been used by the NASA Lewis Research Center for predicting Brayton Cycle compressor and turbine performance for different gases and flow rates are described. These methods were developed by NASA Lewis during the early days of Brayton cycle component development and they can now be applied to the task of predicting the performance of the Closed Brayton Cycle (CBC) Space Station Freedom power system. Computer programs are given for performing these calculations and data from previous NASA Lewis Brayton Compressor and Turbine tests is used to make accurate estimates of the compressor and turbine performance for the CBC power system. Results of these calculations are also given. In general, calculations confirm that the CBC Brayton Cycle contractor has made realistic compressor and turbine performance estimates.

  5. Preliminary design of a Brayton cycle as a standalone Decay Heat Removal system for the Gas-cooled Fast Reactor

    International Nuclear Information System (INIS)

    Epiney, A.; Mikityuk, K.; Chawla, R.; Alpy, N.; Haubensack, D.; Malo, J.Y.

    2009-01-01

    This paper reports a preliminary design study of a Brayton cycle which would be a dedicated, standalone Decay Heat Removal (DHR) loop of the Gas-cooled Fast Reactor (GFR). In comparison to the DHR reference strategy developed during the GFR pre-conceptual design phase (which was completed by the CEA at the end of 2007), the salient feature of this alternative device would be to combine the energetic autonomy of the natural convection process - which is foreseen for operation at high and medium pressures - to the efficiency of the forced convection process which is foreseen for operation down to very low pressures. An analytical model, the so-called 'Brayton scoping' model, is described in the paper. This is based on simplified thermodynamical and aerodynamical equations and was developed to highlight design choices. First simulations of the proposed device's performance during loss-of-coolant-accident (LOCA) transients have been performed using the CATHARE code, and these are also reported. Analysis of the simulation results are consistent with the first insights obtained from usage of the 'Brayton scoping' model, e.g. the turbomachine accelerates during the depressurization process to tend towards a steady rotational speed value which is inversely proportional to the pressure. For small break LOCA events, the device operates successfully as regards its safety function and delivers to the core a relatively unperturbed cooling mass flowrate as a function of pressure change. However, further studies are required for medium to large break sizes, since certain stability concerns have been met in such cases. For example, an unexpected turbomachine stoppage was induced during the transients, resulting in loss of the necessary core cooling mass flow. (author)

  6. Safety, Feasibility, and Efficacy of Vagus Nerve Stimulation Paired With Upper-Limb Rehabilitation After Ischemic Stroke.

    Science.gov (United States)

    Dawson, Jesse; Pierce, David; Dixit, Anand; Kimberley, Teresa J; Robertson, Michele; Tarver, Brent; Hilmi, Omar; McLean, John; Forbes, Kirsten; Kilgard, Michael P; Rennaker, Robert L; Cramer, Steven C; Walters, Matthew; Engineer, Navzer

    2016-01-01

    Recent animal studies demonstrate that vagus nerve stimulation (VNS) paired with movement induces movement-specific plasticity in motor cortex and improves forelimb function after stroke. We conducted a randomized controlled clinical pilot study of VNS paired with rehabilitation on upper-limb function after ischemic stroke. Twenty-one participants with ischemic stroke >6 months before and moderate to severe upper-limb impairment were randomized to VNS plus rehabilitation or rehabilitation alone. Rehabilitation consisted of three 2-hour sessions per week for 6 weeks, each involving >400 movement trials. In the VNS group, movements were paired with 0.5-second VNS. The primary objective was to assess safety and feasibility. Secondary end points included change in upper-limb measures (including the Fugl-Meyer Assessment-Upper Extremity). Nine participants were randomized to VNS plus rehabilitation and 11 to rehabilitation alone. There were no serious adverse device effects. One patient had transient vocal cord palsy and dysphagia after implantation. Five had minor adverse device effects including nausea and taste disturbance on the evening of therapy. In the intention-to-treat analysis, the change in Fugl-Meyer Assessment-Upper Extremity scores was not significantly different (between-group difference, 5.7 points; 95% confidence interval, -0.4 to 11.8). In the per-protocol analysis, there was a significant difference in change in Fugl-Meyer Assessment-Upper Extremity score (between-group difference, 6.5 points; 95% confidence interval, 0.4 to 12.6). This study suggests that VNS paired with rehabilitation is feasible and has not raised safety concerns. Additional studies of VNS in adults with chronic stroke will now be performed. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01669161. © 2015 The Authors.

  7. Catheter-Based Measurements of Absolute Coronary Blood Flow and Microvascular Resistance: Feasibility, Safety, and Reproducibility in Humans.

    Science.gov (United States)

    Xaplanteris, Panagiotis; Fournier, Stephane; Keulards, Daniëlle C J; Adjedj, Julien; Ciccarelli, Giovanni; Milkas, Anastasios; Pellicano, Mariano; Van't Veer, Marcel; Barbato, Emanuele; Pijls, Nico H J; De Bruyne, Bernard

    2018-03-01

    The principle of continuous thermodilution can be used to calculate absolute coronary blood flow and microvascular resistance (R). The aim of the study is to explore the safety, feasibility, and reproducibility of coronary blood flow and R measurements as measured by continuous thermodilution in humans. Absolute coronary flow and R can be calculated by thermodilution by infusing saline at room temperature through a dedicated monorail catheter. The temperature of saline as it enters the vessel, the temperature of blood and saline mixed in the distal part of the vessel, and the distal coronary pressure were measured by a pressure/temperature sensor-tipped guidewire. The feasibility and safety of the method were tested in 135 patients who were referred for coronary angiography. No significant adverse events were observed; in 11 (8.1%) patients, bradycardia and concomitant atrioventricular block appeared transiently and were reversed immediately on interruption of the infusion. The reproducibility of measurements was tested in a subgroup of 80 patients (129 arteries). Duplicate measurements had a strong correlation both for coronary blood flow (ρ=0.841, P <0.001; intraclass correlation coefficient=0.89, P <0.001) and R (ρ=0.780, P <0.001; intraclass correlation coefficient=0.89, P <0.001). In Bland-Altman plots, there was no significant bias or asymmetry. Absolute coronary blood flow (in L/min) and R (in mm Hg/L/min or Wood units) can be safely and reproducibly measured with continuous thermodilution. This approach constitutes a new opportunity for the study of the coronary microcirculation. © 2018 American Heart Association, Inc.

  8. Feasibility study on floating nuclear power plant (2). Safety design study of FNPP. Contract research

    Energy Technology Data Exchange (ETDEWEB)

    Yabuuchi, Noriaki; Shimazaki, Junya; Ochiai, Masaaki [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Takahashi, Masao [Niigata Engineering Co. Ltd., Tokyo (Japan); Nakazawa, Toshio [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Sato, Kazuo [Ishikawajima-Harima Heavy Industries Co. Ltd., Tokyo (Japan)

    2001-02-01

    In the previous report of 'Conceptual Design Study of FNPP (Floating Nuclear Power Plant)', a design study on a concept for FNPP, which is sited off the sea coast on the open sea with water depth of 20m and it is moored on protected sea by the breakwater was conducted and the floating platform guarded by the breakwater was found to be stable enough to install the nuclear power plant from analysis simulating the movement of the platform due to sea wave or wind. In this report, studies on a basic safety design concept of the FNPP, setting natural phenomena for design condition, required safety functions and a review on dynamic analysis of the large floating structure are presented. The studies revealed that the stability of the floating platform is an essential issue for the FNPP soundness, and the design base natural phenomena such as S1 and S2-class storm including S1 and S2-class earthquake should be considered in evaluation of the stability of the floating platform, and it is one of key technical subjects how to set the magnitude of these storm in application of design evaluation on each FNPP case. (J.P.N.)

  9. Dobutamine stress MRI. Part I. Safety and feasibility of dobutamine cardiovascular magnetic resonance in patients suspected of myocardial ischemia

    International Nuclear Information System (INIS)

    Kuijpers, Dirkjan; Janssen, Caroline H.C.; Oudkerk, Matthijs; Dijkman, Paul R.M. van

    2004-01-01

    The aim of the study was to evaluate safety and feasibility of dobutamine cardiovascular magnetic resonance (CMR) in patients with proven or suspected coronary artery disease. Dobutamine CMR was evaluated retrospectively in 400 consecutive patients with suspicion of myocardial ischemia. Dobutamine was infused using an incremental protocol up to 40 μg/kg body weight per minute. All anti-anginal medication was stopped 4 days before the CMR study and infusion time of dobutamine was 6 min per stage. Hemodynamic data, CMR findings and side effects were reported. Patients with contraindications to CMR (metallic implants and claustrophobia) were excluded from analysis. Dobutamine CMR was successfully performed in 355 (89%) patients. Forty-five (11%) patients could not be investigated adequately because of non-cardiac side effects in 29 (7%) and cardiac side effects in 16 (4%) patients. Hypotension (1.5%) and arrhythmias (1%) were the most frequent cardiac side effects. One patient developed a severe complication (ventricular fibrillation) at the end of the study. There were no myocardial infarctions or fatal complications of the stress test. The most frequent non-cardiac side effects were nausea, vomiting and claustrophobia. Age >70 years, prior myocardial infarction and rest wall motion abnormalities showed no significant differences with side effects (P>0.05). Dobutamine CMR is safe and feasible in patients with suspicion of myocardial ischemia. (orig.)

  10. Feasibility and Safety of Overtubes for PEG-Tube Placement in Patients with Head and Neck Cancer

    Directory of Open Access Journals (Sweden)

    Crispin O. Musumba

    2015-01-01

    Full Text Available Background. Percutaneous endoscopic gastrostomy (PEG placement using the “pull” technique is commonly utilized for providing nutritional support in head and neck cancer (HNC patients, but it may be complicated by peristomal metastasis in up to 3% of patients. Overtube-assisted PEG placement might reduce this risk. However, this technique has not been systemically studied for this purpose to date. Methods. Retrospective analysis of consecutive patients with HNC who underwent overtube-assisted PEG placement at Westmead Hospital, Australia, between June 2011 and December 2013. Data were extracted from patients’ endoscopy reports and case notes. We present our technique for PEG insertion and discuss the feasibility and safety of this method. Results. In all 53 patients studied, the PEG tubes were successfully placed using 25 cm long flexible overtubes, in 89% prophylactically (before commencing curative chemoradiotherapy, and in 11% reactively (for treatment of tumor related dysphagia or weight loss. During a median follow-up period of 16 months, 3 (5.7% patients developed peristomal infection and 3 others developed self-limiting peristomal pain. There were no cases of overtube-related adverse events or overt cutaneous metastases observed. Conclusions. Overtube-assisted PEG placement in patients with HNC is a feasible, simple, and safe technique and might be effective for preventing cutaneous metastasis.

  11. Dobutamine stress MRI. Part I. Safety and feasibility of dobutamine cardiovascular magnetic resonance in patients suspected of myocardial ischemia.

    Science.gov (United States)

    Kuijpers, Dirkjan; Janssen, Caroline H C; van Dijkman, Paul R M; Oudkerk, Matthijs

    2004-10-01

    The aim of the study was to evaluate safety and feasibility of dobutamine cardiovascular magnetic resonance (CMR) in patients with proven or suspected coronary artery disease. Dobutamine CMR was evaluated retrospectively in 400 consecutive patients with suspicion of myocardial ischemia. Dobutamine was infused using an incremental protocol up to 40 microg/kg body weight per minute. All anti-anginal medication was stopped 4 days before the CMR study and infusion time of dobutamine was 6 min per stage. Hemodynamic data, CMR findings and side effects were reported. Patients with contraindications to CMR (metallic implants and claustrophobia) were excluded from analysis. Dobutamine CMR was successfully performed in 355 (89%) patients. Forty-five (11%) patients could not be investigated adequately because of non-cardiac side effects in 29 (7%) and cardiac side effects in 16 (4%) patients. Hypotension (1.5%) and arrhythmias (1%) were the most frequent cardiac side effects. One patient developed a severe complication (ventricular fibrillation) at the end of the study. There were no myocardial infarctions or fatal complications of the stress test. The most frequent non-cardiac side effects were nausea, vomiting and claustrophobia. Age >70 years, prior myocardial infarction and rest wall motion abnormalities showed no significant differences with side effects (P>0.05). Dobutamine CMR is safe and feasible in patients with suspicion of myocardial ischemia. Copyright 2004 Springer-Verlag

  12. Dobutamine stress MRI. Part I. Safety and feasibility of dobutamine cardiovascular magnetic resonance in patients suspected of myocardial ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Kuijpers, Dirkjan [State University and Academic Hospital Groningen, Department of Radiology, Groningen (Netherlands); Bronovo Hospital, Department of Radiology and Cardiology, Bronovolaan 1, P.O. Box 96900, The Hague (Netherlands); Janssen, Caroline H.C.; Oudkerk, Matthijs [State University and Academic Hospital Groningen, Department of Radiology, Groningen (Netherlands); Dijkman, Paul R.M. van [Bronovo Hospital, Department of Radiology and Cardiology, Bronovolaan 1, P.O. Box 96900, The Hague (Netherlands)

    2004-10-01

    The aim of the study was to evaluate safety and feasibility of dobutamine cardiovascular magnetic resonance (CMR) in patients with proven or suspected coronary artery disease. Dobutamine CMR was evaluated retrospectively in 400 consecutive patients with suspicion of myocardial ischemia. Dobutamine was infused using an incremental protocol up to 40 {mu}g/kg body weight per minute. All anti-anginal medication was stopped 4 days before the CMR study and infusion time of dobutamine was 6 min per stage. Hemodynamic data, CMR findings and side effects were reported. Patients with contraindications to CMR (metallic implants and claustrophobia) were excluded from analysis. Dobutamine CMR was successfully performed in 355 (89%) patients. Forty-five (11%) patients could not be investigated adequately because of non-cardiac side effects in 29 (7%) and cardiac side effects in 16 (4%) patients. Hypotension (1.5%) and arrhythmias (1%) were the most frequent cardiac side effects. One patient developed a severe complication (ventricular fibrillation) at the end of the study. There were no myocardial infarctions or fatal complications of the stress test. The most frequent non-cardiac side effects were nausea, vomiting and claustrophobia. Age >70 years, prior myocardial infarction and rest wall motion abnormalities showed no significant differences with side effects (P>0.05). Dobutamine CMR is safe and feasible in patients with suspicion of myocardial ischemia. (orig.)

  13. Safety and feasibility of countering neurological impairment by intravenous administration of autologous cord blood in cerebral palsy

    Directory of Open Access Journals (Sweden)

    Lee Young-Ho

    2012-03-01

    Full Text Available Abstract Backgrounds We conducted a pilot study of the infusion of intravenous autologous cord blood (CB in children with cerebral palsy (CP to assess the safety and feasibility of the procedure as well as its potential efficacy in countering neurological impairment. Methods Patients diagnosed with CP were enrolled in this study if their parents had elected to bank their CB at birth. Cryopreserved CB units were thawed and infused intravenously over 10~20 minutes. We assessed potential efficacy over 6 months by brain magnetic resonance imaging (MRI-diffusion tensor imaging (DTI, brain perfusion single-photon emission computed tomography (SPECT, and various evaluation tools for motor and cognitive functions. Results Twenty patients received autologous CB infusion and were evaluated. The types of CP were as follows: 11 quadriplegics, 6 hemiplegics, and 3 diplegics. Infusion was generally well-tolerated, although 5 patients experienced temporary nausea, hemoglobinuria, or urticaria during intravenous infusion. Diverse neurological domains improved in 5 patients (25% as assessed with developmental evaluation tools as well as by fractional anisotropy values in brain MRI-DTI. The neurologic improvement occurred significantly in patients with diplegia or hemiplegia rather than quadriplegia. Conclusions Autologous CB infusion is safe and feasible, and has yielded potential benefits in children with CP.

  14. Safety, feasibility, and acceptability of visual inspection with acetic acid and immediate treatment with cryotherapy in rural Laos.

    Science.gov (United States)

    Phongsavan, Keokedthong; Phengsavanh, Alongkone; Wahlström, Rolf; Marions, Lena

    2011-09-01

    To assess the safety, acceptability, and feasibility of visual inspection with acetic acid (VIA) followed by immediate treatment with cryotherapy as a single-visit approach for the prevention of cervical cancer among women in rural Laos. In 2009, women from 2 provinces in Laos were recruited for cervical cancer screening using VIA. If the inspection of the cervix showed a well-defined acetowhite lesion close to the os, immediate cryotherapy was offered. Of the 1926 women who were included, 134 (7.0%) tested positive on VIA. Of these, 113 (84.3%) underwent immediate cryotherapy and none declined treatment. One year after immediate cryotherapy, 77 (68.1%) women returned for a follow-up assessment and 68 (88.3%) were now VIA-negative. There was no report of a major complication during or after treatment. The acceptance of both VIA and cryotherapy was high. Visual inspection with acetic acid is a simple test that requires minimal infrastructure and expenditure. Integration of VIA with cryotherapy at the primary care level may constitute a feasible program for the prevention of cervical cancer in Laos. Copyright © 2011 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  15. Performance analysis of Brayton cycle system for space power reactor

    International Nuclear Information System (INIS)

    Li Zhi; Yang Xiaoyong; Zhao Gang; Wang Jie; Zhang Zuoyi

    2017-01-01

    The closed Brayton cycle system now is the potential choice as the power conversion system for High Temperature Gas-cooled Reactors because of its high energy conversion efficiency and compact configuration. The helium is the best working fluid for the system for its chemical stability and small neutron absorption cross section. However, the Helium has small mole mass and big specific volume, which would lead to larger pipes and heat exchanger. What's more, the big compressor enthalpy rise of helium would also lead to an unacceptably large number of compressor's stage. For space use, it's more important to satisfy the limit of the system's volume and mass, instead of the requirement of the system's thermal capacity. So Noble-Gas binary mixture of helium and xenon is presented as the working fluid for space Brayton cycle. This paper makes a mathematical model for space Brayton cycle system by Fortran language, then analyzes the binary mixture of helium and xenon's properties and effects on power conversion units of the space power reactor, which would be helpful to understand and design the space power reactor. The results show that xenon would lead to a worse system's thermodynamic property, the cycle's efficiency and specific power decrease as xenon's mole fraction increasing. On the other hand, proper amount of xenon would decrease the enthalpy changes in turbomachines, which would be good for turbomachines' design. Another optimization method – the specific power optimization is also proposed to make a comparison. (author)

  16. High exergetic modified Brayton cycle with thermoelectric energy conversion

    International Nuclear Information System (INIS)

    Yazawa, Kazuaki; Fisher, Timothy S.; Groll, Eckhard A.; Shakouri, Ali

    2017-01-01

    Highlights: • Modified Brayton cycle with thermoelectric generators. • 1 kW power output scale hybrid gas turbine for residential applications. • Low profile TEGs are embedded in combustor/recuperator/heat-exchangers. • Analytical primary energy efficiency achieves more than 40%. - Abstract: A novel concept using thermoelectric direct power generators (TEGs) integrated into a 1 kW scale miniature Brayton cycle is investigated based on an analytical study. The work considers a residential scale application aiming to achieve 40% primary energy efficiency in contrast to the state-of-the-art miniature gas turbine alone, which can only achieve <16%. A topping cycle TEG for a hot gas temperature at 1600–1700 °C is embedded in the combustor scale of a kitchen stove. This TEG converts a fraction of the heat into electricity, while all the remaining thermal energy proceeds to the Brayton cycle. Turbine-inlet gas temperature regulates to 800–1100 °C by optimizing the air mixture. A second TEG is built in the recuperator; hence, the associated temperature is similar to that of a vehicle exhaust. A third TEG is used for waste heat recovery from flue gas, and then the downstream heat flow is used by a combined-heat-power system. By taking advantage of low-profile modules, the TEG embedded heat exchanges can be compact and low-cost at 0.2–0.3 $/W. The figure-of-merit of the thermoelectric materials considers ZT 1.0–1.8. Assuming that all advanced components are utilized, the primary energy efficiency predicts 42% with power output 720 W from the alternator and 325 W from the TEGs out of 0.456 g/s of a pipeline natural gas input.

  17. Feasibility and safety of extended adjuvant temozolomide beyond six cycles for patients with glioblastoma.

    Science.gov (United States)

    Hsieh, S Yp; Chan, D Tm; Kam, M Km; Loong, H Hf; Tsang, W K; Poon, D Mc; Ng, S Cp; Poon, W S

    2017-12-01

    Temozolomide is the first chemotherapeutic agent proven effective for patients with newly diagnosed glioblastoma. The drug is well tolerated for its low toxicity. The current standard practice is concomitant chemoradiotherapy for 6 weeks followed by 6 cycles of adjuvant temozolomide. Some Caucasian studies have suggested that patients might benefit from extended adjuvant cycles of temozolomide (>6 cycles) to lengthen both progression-free survival and overall survival. In the present study, we compared differences in survival and toxicity profile between patients who received conventional 6-cycle temozolomide and those who received more than 6 cycles of temozolomide. Patients with newly diagnosed glioblastoma without progressive disease and completed concomitant chemoradiotherapy during a 4-year period were studied. Progression-free survival was compared using Kaplan-Meier survival curves. t Test, U test, and correlation were chosen accordingly to examine the impact of age, extent of resection, MGMT promoter methylation status and adjuvant cycles on progression-free survival. For factors with a P value of cycles of temozolomide (n=7) and 43.4 months for those who received more than 6 cycles (n=7) [P=0.007, log-rank test]. Two patients in the former group and one in the latter group encountered grade 1 toxicity and recovered following dose adjustment. Cycles of adjuvant temozolomide were correlated with progression-free survival (P=0.016, hazard ratio=0.68). Extended cycles of temozolomide are safe and feasible for Chinese patients with disease responsive to temozolomide.

  18. Morsleben repository - Interdependence of technical feasibility and functionality of geotechnical barriers and safety case development

    International Nuclear Information System (INIS)

    Wollrath, Juergen; Mauke, Ralf; Mohlfeld, Matthias; Niemeyer, Matthias; Becker, Dirk-Alexander

    2014-01-01

    Based on a selection procedure whereby ten existing mines had been taken into consideration, the Morsleben repository for radioactive waste (ERAM) was built in a former mine for potash and rock salt production. The specific concerns and objectives of a repository for radioactive waste could not be taken into account when the mine was built at the beginning of the last century. Irrespective of this, altogether about 37 000 m 3 of low-level and intermediate-level radioactive waste was stored in several areas of the mine between 1971 and 1991 and from 1994 to 1998. In the scope of the ongoing licensing procedure, the safety of the 'historically grown' repository needs to be demonstrated for the phase after it has been sealed. (authors)

  19. The Feasibility and Safety of Surgery in Patients Receiving Immune Checkpoint Inhibitors: A Retrospective Study

    Directory of Open Access Journals (Sweden)

    Alexandra W. Elias

    2017-06-01

    Full Text Available Immune checkpoint inhibitors (ICI are revolutionizing care for cancer patients. The list of malignancies for which the Food and Drug Administration is granting approval is rapidly increasing. Furthermore, there is a concomitant increase in clinical trials incorporating ICI. However, the safety of ICI in patients undergoing surgery remains unclear. Herein, we assessed the safety of ICI in the perioperative setting at a single center. We conducted a retrospective review of patients who underwent planned surgery while receiving ICI in the perioperative setting from 2012 to 2016. We collected 30-day postoperative morbidity and mortality utilizing the Clavien–Dindo classification system. We identified 17 patients who received perioperative ICI in 22 operations. Patients were diagnosed with melanoma (n = 14, renal cell carcinoma (n = 2, and urothelial carcinoma (n = 1. Therapies included pembrolizumab (n = 10, ipilimumab (n = 5, atezolizumab (n = 5, and ipilimumab/nivolumab (n = 2. Procedures included cutaneous/subcutaneous resection (n = 6, lymph node resection (n = 5, small bowel resection (n = 5, abdominal wall resection (n = 3, other abdominal surgery (n = 3, orthopedic surgery (n = 1, hepatic resection (n = 1, and neurosurgery (n = 2. There were no Grade III–IV Clavien–Dindo complications. There was one death secondary to ventricular fibrillation in the setting of coronary artery disease. ICI appear safe in the perioperative setting, involving multiple different types of surgery, and likely do not need to be stopped in the perioperative setting. Further studies are warranted to confirm these findings.

  20. Feasibility, safety and image quality of cardiac FDG studies during hyperinsulinaemic-euglycaemic clamping

    International Nuclear Information System (INIS)

    Bax, Jeroen J.; Visser, Frans C.; Lingen, Arthur van; Visser, Cees A.; Poldermans, Don; Elhendy, Abdou; Boersma, Eric

    2002-01-01

    Fluorine-18 fluorodeoxyglucose (FDG) imaging for the assessment of myocardial viability has become an integral part of the diagnostic and prognostic work-up of patients with ischaemic cardiomyopathy. To ensure good image quality, in particular in patients with diabetes mellitus, hyperinsulinaemic-euglycaemic clamping has been proposed. In this study we evaluated the safety and the image quality of cardiac FDG imaging during clamping in a large group of patients, including a subgroup with diabetes mellitus. The incidence of viability (on both a segment and a patient basis) was also determined for patients with and without diabetes mellitus. The safety and image quality of cardiac FDG studies during clamping were evaluated in 131 patients, including 19 with diabetes mellitus. Image quality was assessed visually and quantitatively using heart-to-lung (H/L), heart-to-liver (H/Li) and myocardium-to-background (M/B) ratios. Blood samples were drawn at baseline and at the time of FDG injection to determine levels of glucose, free fatty acids and insulin. The metabolic circumstances were optimal for FDG imaging: high insulin levels, low free fatty acid levels and glucose levels in the normal range (levels of substrates were comparable between patients with and patients without diabetes mellitus). No serious side-effects occurred in any patient. Image quality (assessed visually) was good in all patients. The quantitative parameters of image quality (H/L, H/Li and M/B) were comparable between patients with and patients without diabetes mellitus. The incidence of viability was high: 38% of patients without and 58% of patients with diabetes mellitus had substantial viability despite contractile dysfunction. It is concluded that cardiac FDG imaging during clamping is safe and provides excellent image quality, including in patients with diabetes mellitus. The incidence of viability is high, in particular in patients with diabetes mellitus. (orig.)

  1. Two-port cholecystectomy maintains safety and feasibility in benign gallbladder diseases: a comparative study.

    Science.gov (United States)

    Lee, Sang Chul; Choi, Byeong-Jo; Kim, Say-June

    2014-01-01

    In an effort to overcome the limitations of single-port laparoscopic cholecystectomy (LC) while preserving the cosmetic benefits of reduced ports cholecystectomy, we have developed a 2-port LC that allows for the full, unrestricted use of 4 laparoscopic instruments. We retrospectively analyzed data of patients who had undergone either 4-port LC or 2-port LC for benign gallbladder diseases between March 2007 and March 2013. Two incisions of 2-port LC were composed of an umbilical incision as the manner of single-port laparoscopic surgery and a 5-mm epigastric incision. These two incisions were utilized for comfortable bimanual manipulation under the liver-elevated vision provided by a liver retractor. During the study period, 766 patients underwent LC; 263 (34.3%) started with 4-port LC, and 503 (65.7%) started with 2-port LC. Of patients started with 2-port LC, 486 patients (96.6%) was ended up with 2-port without open conversion or addition of port(s). The two groups had similar operative time, open conversion rate, incidence of complications, analgesic requirement, and length of postoperative hospital stay. Multivariate analyses revealed that the independent factors related to prolonged operative time (≥ 90 th percentile) in 2-port LC were the presence of cholecystitis (odds ratio [OR] 2.412, 95% CI 1.246-4.668, p = 0.009) and admission through the emergency department (OR 2.132, 95% CI 1.135-4.004, p = 0.019). This study suggests that 2-port LC for benign gallbladder diseases is as safe and feasible as 4-port LC when it is performed by surgeons trained in conventional laparoscopic techniques. Copyright © 2014 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  2. The feasibility of modelling coupled processes in safety analysis of spent nuclear fuel disposal

    Energy Technology Data Exchange (ETDEWEB)

    Rasilainen, K. [VTT Energy, Espoo (Finland); Luukkonen, A.; Niemi, A.; Poellae, J. [VTT Communities and Infrastructure, Espoo (Finland); Olin, M. [VTT Chemical Technology, Espoo (Finland)

    1999-07-01

    The potential of applying coupled modelling in the Finnish safety analysis programme has been reviewed. The study focused on the migration of radionuclides escaping from a spent fuel repository planned to be excavated in fractured bedrock. Two effects that can trigger various couplings in and around a spent fuel repository in Finland were studied in detail; namely heat generation in the spent fuel and the presence of deep, saline groundwaters. The latter have been observed in coastal areas. A systematic survey of the requirements of coupled modelling identified features that render such migration calculations a challenging task. In groundwater flow modelling there appears to be wide ranging uncertainty related to conceptualisation of flow systems and to the corresponding input data. In terms of migration related chemistry there appear to be large gaps in the underlying thermodynamic database for geochemical systems. Rock mechanical predictions are heavily dependent on knowing the location, structure and properties of dominant fractures; information which is extremely difficult to obtain. Conduction and convection of heat is understood well in principle. On the basis of this review, it appears that coupled migration modelling may not yet be at the stage of development that would allow its use as a standard modelling tool in performance assessments. However, a firmer basis for the conclusions reached can only be obtained after a systematic modelling exercise on a relevant and real migration problem has been carried out. (orig.)

  3. The feasibility of modelling coupled processes in safety analysis of spent nuclear fuel disposal

    International Nuclear Information System (INIS)

    Rasilainen, K.; Luukkonen, A.; Niemi, A.; Poellae, J.; Olin, M.

    1999-01-01

    The potential of applying coupled modelling in the Finnish safety analysis programme has been reviewed. The study focused on the migration of radionuclides escaping from a spent fuel repository planned to be excavated in fractured bedrock. Two effects that can trigger various couplings in and around a spent fuel repository in Finland were studied in detail; namely heat generation in the spent fuel and the presence of deep, saline groundwaters. The latter have been observed in coastal areas. A systematic survey of the requirements of coupled modelling identified features that render such migration calculations a challenging task. In groundwater flow modelling there appears to be wide ranging uncertainty related to conceptualisation of flow systems and to the corresponding input data. In terms of migration related chemistry there appear to be large gaps in the underlying thermodynamic database for geochemical systems. Rock mechanical predictions are heavily dependent on knowing the location, structure and properties of dominant fractures; information which is extremely difficult to obtain. Conduction and convection of heat is understood well in principle. On the basis of this review, it appears that coupled migration modelling may not yet be at the stage of development that would allow its use as a standard modelling tool in performance assessments. However, a firmer basis for the conclusions reached can only be obtained after a systematic modelling exercise on a relevant and real migration problem has been carried out. (orig.)

  4. New exergy analysis of a regenerative closed Brayton cycle

    International Nuclear Information System (INIS)

    Naserian, Mohammad Mahdi; Farahat, Said; Sarhaddi, Faramarz

    2017-01-01

    Highlights: • The maximum power is studied relating to time and size constraints variations. • The influence of time and size constraints on exergy destruction are investigated. • The definitions of heat exergy, and second law efficiency are modified. - Abstract: In this study, the optimal performance of a regenerative closed Brayton cycle is sought through power maximization. Optimization is performed on the output power as the objective function using genetic algorithm. In order to take into account the time and the size constraints in current problem, the dimensionless mass-flow parameter is used. The influence of the unavoidable exergy destruction due to finite-time constraint is taken into account by developing the definition of heat exergy. Finally, the improved definitions are proposed for heat exergy, and the second law efficiency. Moreover, the new definitions will be compared with the conventional ones. For example, at a specified dimensionless mass-flow parameter, exergy overestimation in conventional definition, causes about 31% lower estimation of the second law efficiency. These results could be expected to be utilized in future solar thermal Brayton cycle assessment and optimization.

  5. Randomized Controlled Study on Safety and Feasibility of Transfusion Trigger Score of Emergency Operations.

    Science.gov (United States)

    Liu, De-Xing; Liu, Jin; Zhang, Fan; Zhang, Qiu-Ying; Xie, Mian; Zhu, Zhao-Qiong

    2015-07-05

    totally (100%) conformed to the requirements of the transfusion guideline to RBC infusion, which was higher than that of the control group (81.25%), P differences in utilization rates of autologous blood of the two groups; the utilization rates of allogeneic RBC, total allogeneic RBC and total RBC were 48.48%, 51.5%, and 75.7% in POTTS-E group, which were lower than those of the control group (84.3%, 84.3%, and 96.8%) P groups were all lower than those of control group (4.0 [2.0, 4.0], 4.0 [2.0, 6.0] and 5.8 [2.7, 8.2]), P used to guide the application of RBC. There are no differences in the recent prognosis of patients with the traditional transfusion guidelines. This scheme is safe; Compared with doctor experience-based subjective assessment, the scoring scheme was closer to patient physiological needs for transfusion and more reasonable; Utilization rate and the per capita consumption of RBC are obviously declined, which has clinical significance and is feasible. Based on the abovementioned three points, POTTS-E scores scheme is safe, reasonable, and practicable and has the value for carrying out multicenter and large sample clinical researches.

  6. Feasibility and safety of electrochemotherapy (ECT) in the pancreas: a pre-clinical investigation

    International Nuclear Information System (INIS)

    Girelli, Roberto; Prejanò, Simona; Cataldo, Ivana; Corbo, Vincenzo; Martini, Lucia; Scarpa, Aldo; Claudio, Bassi

    2015-01-01

    Pancreatic ductal adenocarcinoma (PDAC) is a lethal disease generally refractory to standard chemotherapeutic agents; therefore improvements in anticancer therapies are mandatory. A major determinant of therapeutic resistance in PDAC is the poor drug delivery to neoplastic cells, mainly due to an extensive fibrotic reaction. Electroporation can be used in vivo to increase cancer cells’ local uptake of chemotherapeutics (electrochemotherapy, ECT), thus leading to an enhanced tumour response rate. In the present study, we evaluated the in vivo effects of reversible electroporation in normal pancreas in a rabbit experimental model. We also tested the effect of electroporation on pancreatic cancer cell lines in order to evaluate their increased sensitivity to chemotherapeutic agents. The application in vivo of the European Standard Operating Procedure of Electrochemotherapy (ESOPE) pulse protocol (1000 V/cm, 8 pulses, 100 μs, 5 KHz) was tested on the pancreas of normal New Zealand White Rabbits and short and long-term toxicity were assessed. PANC1 and MiaPaCa2 cell lines were tested for in vitro electrochemotherapy experiments with and without electroporation. Levels of cell permeabilization were determined by flow cytometry, whereas cell viability and drug (cisplatin and bleomycin) sensitivity of pulsed cells were measured by 3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl) -2H-tetrazolium (MTS) assay. In healthy rabbits, neither systemic nor local toxic effects due to the electroporation procedure were observed, demonstrating the safety of the optimized electric parameters in the treatment of the pancreas in vivo. In parallel, we established an optimized protocol for ECT in vitro that determined an enhanced anti-cancer effect of bleomycin and cisplatin with respect to treatment without electroporation. Our data suggest that electroporation is a safe procedure in the treatment of PDAC because it does not affect normal pancreatic parenchyma

  7. Initial experience with a robotically operated video optical telescopic-microscope in cranial neurosurgery: feasibility, safety, and clinical applications.

    Science.gov (United States)

    Gonen, Lior; Chakravarthi, Srikant S; Monroy-Sosa, Alejandro; Celix, Juanita M; Kojis, Nathaniel; Singh, Maharaj; Jennings, Jonathan; Fukui, Melanie B; Rovin, Richard A; Kassam, Amin B

    2017-05-01

    OBJECTIVE The move toward better, more effective optical visualization in the field of neurosurgery has been a focus of technological innovation. In this study, the authors' objectives are to describe the feasibility and safety of a new robotic optical platform, namely, the robotically operated video optical telescopic-microscope (ROVOT-m), in cranial microsurgical applications. METHODS A prospective database comprising patients who underwent a cranial procedure between April 2015 and September 2016 was queried, and the first 200 patients who met the inclusion criteria were selected as the cohort for a retrospective chart review. Only adults who underwent microsurgical procedures in which the ROVOT-m was used were considered for the study. Preoperative, intraoperative, and postoperative data were retrieved from electronic medical records. The authors address the feasibility and safety of the ROVOT-m by studying various intraoperative variables and by reporting perioperative morbidity and mortality, respectively. To assess the learning curve, cranial procedures were categorized into 6 progressively increasing complexity groups. The main categories of pathology were I) intracerebral hemorrhages (ICHs); II) intraaxial tumors involving noneloquent regions or noncomplex extraaxial tumors; III) intraaxial tumors involving eloquent regions; IV) skull base pathologies; V) intraventricular lesions; and VI) cerebrovascular lesions. In addition, the entire cohort was evenly divided into early and late cohorts. RESULTS The patient cohort comprised 104 female (52%) and 96 male (48%) patients with a mean age of 56.7 years. The most common pathological entities encountered were neoplastic lesions (153, 76.5%), followed by ICH (20, 10%). The distribution of cases by complexity categories was 11.5%, 36.5%, 22%, 20%, 3.5%, and 6.5% for Categories I, II, II, IV, V, and VI, respectively. In all 200 cases, the surgical goal was achieved without the need for intraoperative conversion

  8. Nintendo Wii Fit as an adjunct to physiotherapy following lower limb fractures: preliminary feasibility, safety and sample size considerations.

    Science.gov (United States)

    McPhail, S M; O'Hara, M; Gane, E; Tonks, P; Bullock-Saxton, J; Kuys, S S

    2016-06-01

    The Nintendo Wii Fit integrates virtual gaming with body movement, and may be suitable as an adjunct to conventional physiotherapy following lower limb fractures. This study examined the feasibility and safety of using the Wii Fit as an adjunct to outpatient physiotherapy following lower limb fractures, and reports sample size considerations for an appropriately powered randomised trial. Ambulatory patients receiving physiotherapy following a lower limb fracture participated in this study (n=18). All participants received usual care (individual physiotherapy). The first nine participants also used the Wii Fit under the supervision of their treating clinician as an adjunct to usual care. Adverse events, fracture malunion or exacerbation of symptoms were recorded. Pain, balance and patient-reported function were assessed at baseline and discharge from physiotherapy. No adverse events were attributed to either the usual care physiotherapy or Wii Fit intervention for any patient. Overall, 15 (83%) participants completed both assessments and interventions as scheduled. For 80% power in a clinical trial, the number of complete datasets required in each group to detect a small, medium or large effect of the Wii Fit at a post-intervention assessment was calculated at 175, 63 and 25, respectively. The Nintendo Wii Fit was safe and feasible as an adjunct to ambulatory physiotherapy in this sample. When considering a likely small effect size and the 17% dropout rate observed in this study, 211 participants would be required in each clinical trial group. A larger effect size or multiple repeated measures design would require fewer participants. Copyright © 2015 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  9. Safety and feasibility of modified chair-yoga on functional outcome among elderly at risk for falls

    Directory of Open Access Journals (Sweden)

    Mary Lou Galantino

    2012-01-01

    Full Text Available Falls are among the most common problems affecting older adults. At least 50% of those over the age of 80 fall annually. The goal of this pilot study was to assess the safety and feasibility of structured yoga in an elderly population with fall risk. Seniors at risk for falls were identified and enrolled in a single arm pilot trial. A chair based yoga program was provided twice a week for 8 weeks. The program was designed from previously published pilot data. A battery of validated instruments was administered at baseline and week eight and was used to identify which instruments may be sensitive to change as a result of a yoga program. Among sixteen seniors (median age of 88 with a previous history of falls, 87% provided data for assessment at the end of the intervention. Two patients withdrew, one due to a fall outside the institution and the other due to lack of time and interest. There were no adverse events during the yoga sessions. Paired-t tests compared pre-post changes and gains were noted in Fear of Falling (5.27 to 2.60; P = 0.029 and SPPB sit to stand subscale (0.31 to 1.00; P =.022. Improved trends were noted in anxiety and the timed up and go assessments. We found the modified chair-yoga program is safe and recruitment is feasible. Our data suggests that yoga may be beneficial in improving mobility and reducing fear of falling which warrants additional research via randomized controlled trial.

  10. Design and analysis of helium Brayton power cycles for HiPER reactor

    Energy Technology Data Exchange (ETDEWEB)

    Sánchez, Consuelo, E-mail: csanchez@ind.uned.es [Dpto. Ingeniería Energética UNED, Madrid (Spain); Juárez, Rafael; Sanz, Javier [Dpto. Ingeniería Energética UNED, Madrid (Spain); Instituto de Fusión Nuclear/UPM, Madrid (Spain); Perlado, Manuel [Instituto de Fusión Nuclear/UPM, Madrid (Spain)

    2013-10-15

    Highlights: ► A helium Brayton cycle has been designed integrating the two energy sources of HiPER. ► The Brayton cycle has intercooling stages and a recovery process. ► The low temperature of HiPER heat sources results in low cycle efficiency (35.2%). ► Two inter-cooling stages and a reheating process increases efficiency to over 37%. ► Helium Brayton cycles are to be considered as candidates for HiPER power cycles. -- Abstract: Helium Brayton cycles have been studied as power cycles for both fission and fusion reactors obtaining high thermal efficiency. This paper studies several technological schemes of helium Brayton cycles applied for the HiPER reactor proposal. Since HiPER integrates technologies available at short term, its working conditions results in a very low maximum temperature of the energy sources, something that limits the thermal performance of the cycle. The aim of this work is to analyze the potential of the helium Brayton cycles as power cycles for HiPER. Several helium Brayton cycle configurations have been investigated with the purpose of raising the cycle thermal efficiency under the working conditions of HiPER. The effects of inter-cooling and reheating have specifically been studied. Sensitivity analyses of the key cycle parameters and component performances on the maximum thermal efficiency have also been carried out. The addition of several inter-cooling stages in a helium Brayton cycle has allowed obtaining a maximum thermal efficiency of over 36%, and the inclusion of a reheating process may also yield an added increase of nearly 1 percentage point to reach 37%. These results confirm that helium Brayton cycles are to be considered among the power cycle candidates for HiPER.

  11. Design and analysis of helium Brayton power cycles for HiPER reactor

    International Nuclear Information System (INIS)

    Sánchez, Consuelo; Juárez, Rafael; Sanz, Javier; Perlado, Manuel

    2013-01-01

    Highlights: ► A helium Brayton cycle has been designed integrating the two energy sources of HiPER. ► The Brayton cycle has intercooling stages and a recovery process. ► The low temperature of HiPER heat sources results in low cycle efficiency (35.2%). ► Two inter-cooling stages and a reheating process increases efficiency to over 37%. ► Helium Brayton cycles are to be considered as candidates for HiPER power cycles. -- Abstract: Helium Brayton cycles have been studied as power cycles for both fission and fusion reactors obtaining high thermal efficiency. This paper studies several technological schemes of helium Brayton cycles applied for the HiPER reactor proposal. Since HiPER integrates technologies available at short term, its working conditions results in a very low maximum temperature of the energy sources, something that limits the thermal performance of the cycle. The aim of this work is to analyze the potential of the helium Brayton cycles as power cycles for HiPER. Several helium Brayton cycle configurations have been investigated with the purpose of raising the cycle thermal efficiency under the working conditions of HiPER. The effects of inter-cooling and reheating have specifically been studied. Sensitivity analyses of the key cycle parameters and component performances on the maximum thermal efficiency have also been carried out. The addition of several inter-cooling stages in a helium Brayton cycle has allowed obtaining a maximum thermal efficiency of over 36%, and the inclusion of a reheating process may also yield an added increase of nearly 1 percentage point to reach 37%. These results confirm that helium Brayton cycles are to be considered among the power cycle candidates for HiPER

  12. Pressure-controlled intermittent coronary sinus occlusion (PICSO) in acute ST-segment elevation myocardial infarction: results of the Prepare RAMSES safety and feasibility study

    NARCIS (Netherlands)

    van de Hoef, Tim P.; Nijveldt, Robin; van der Ent, Martin; Neunteufl, Thomas; Meuwissen, Martijn; Khattab, Ahmed; Berger, Rudolf; Kuijt, Wichert J.; Wykrzykowska, Joanna; Tijssen, Jan G. P.; van Rossum, Albert C.; Stone, Gregg W.; Piek, Jan J.

    2015-01-01

    Pressure-controlled intermittent coronary sinus occlusion (PICSO) may improve myocardial perfusion after pPCI. We evaluated the safety and feasibility of PICSO after pPCI for STEMI, and explored its effects on infarct size and myocardial function. Thirty patients were enrolled following successful

  13. Optimization of the performance characteristics in an irreversible magnetic Brayton refrigeration cycle

    International Nuclear Information System (INIS)

    Wang Hao; Liu Sanqiu

    2008-01-01

    An irreversible cycle model of magnetic Brayton refrigerators is established, in which the thermal resistance and irreversibility in the two adiabatic processes are taken into account. Expressions for several important performance parameters, such as the coefficient of performance, cooling rate and power input are derived. Moreover, the optimal performance parameters are obtained at the maximum coefficient of performance. The optimization region (or criteria) for an irreversible magnetic Brayton refrigerator is obtained. The results obtained here have general significance and will be helpful to understand deeply the performance of a magnetic Brayton refrigeration cycle

  14. Enhancing power cycle efficiency for a supercritical Brayton cycle power system using tunable supercritical gas mixtures

    Science.gov (United States)

    Wright, Steven A.; Pickard, Paul S.; Vernon, Milton E.; Radel, Ross F.

    2017-08-29

    Various technologies pertaining to tuning composition of a fluid mixture in a supercritical Brayton cycle power generation system are described herein. Compounds, such as Alkanes, are selectively added or removed from an operating fluid of the supercritical Brayton cycle power generation system to cause the critical temperature of the fluid to move up or down, depending upon environmental conditions. As efficiency of the supercritical Brayton cycle power generation system is substantially optimized when heat is rejected near the critical temperature of the fluid, dynamically modifying the critical temperature of the fluid based upon sensed environmental conditions improves efficiency of such a system.

  15. Thermodynamic Modeling for Open Combined Regenerative Brayton and Inverse Brayton Cycles with Regeneration before the Inverse Cycle

    Directory of Open Access Journals (Sweden)

    Lingen Chen

    2012-01-01

    Full Text Available A thermodynamic model of an open combined regenerative Brayton and inverse Brayton cycles with regeneration before the inverse cycle is established in this paper by using thermodynamic optimization theory. The flow processes of the working fluid with the pressure drops and the size constraint of the real power plant are modeled. There are 13 flow resistances encountered by the working fluid stream for the cycle model. Four of these, the friction through the blades and vanes of the compressors and the turbines, are related to the isentropic efficiencies. The remaining nine flow resistances are always present because of the changes in flow cross-section at the compressor inlet of the top cycle, regenerator inlet and outlet, combustion chamber inlet and outlet, turbine outlet of the top cycle, turbine outlet of the bottom cycle, heat exchanger inlet, and compressor inlet of the bottom cycle. These resistances associated with the flow through various cross-sectional areas are derived as functions of the compressor inlet relative pressure drop of the top cycle, and control the air flow rate, the net power output and the thermal efficiency. The analytical formulae about the power output, efficiency and other coefficients are derived with 13 pressure drop losses. It is found that the combined cycle with regenerator can reach higher thermal efficiency but smaller power output than those of the base combined cycle at small compressor inlet relative pressure drop of the top cycle.

  16. Cost Analysis of an Air Brayton Receiver for a Solar Thermal Electric Power System in Selected Annual Production Volumes

    Science.gov (United States)

    1981-01-01

    Pioneer Engineering and Manufacturing Company estimated the cost of manufacturing and Air Brayton Receiver for a Solar Thermal Electric Power System as designed by the AiResearch Division of the Garrett Corporation. Production costs were estimated at annual volumes of 100; 1,000; 5,000; 10,000; 50,000; 100,000 and 1,000,000 units. These costs included direct labor, direct material and manufacturing burden. A make or buy analysis was made of each part of each volume. At high volumes special fabrication concepts were used to reduce operation cycle times. All costs were estimated at an assumed 100% plant capacity. Economic feasibility determined the level of production at which special concepts were to be introduced. Estimated costs were based on the economics of the last half of 1980. Tooling and capital equipment costs were estimated for ach volume. Infrastructure and personnel requirements were also estimated.

  17. Thermal performance of Brayton power cycles. A study based on high-temperature gas-cooled reactors

    International Nuclear Information System (INIS)

    Herranz, Luis E.; Linares, Jose I.; Moratilla, Beatriz Y.

    2005-01-01

    Power cycles optimization has become an essential ingredient to achieve sustainability and improve economic competitiveness of forthcoming Generation IV designs. This paper investigates performance of several configurations of direct helium Brayton cycles. An optimum layout is proposed based on multiple intercooled compression stages and in-between turbines reheating: C(IC) 2 HTRTX. Under the hypotheses and approximations made, a 59% is estimated and it increases even further (67%) when the foreseen technological development is considered. A sensitive analysis identified key components and variables for cycle performance. Particular attention is paid to the effect of the extracted gas mass fraction for reheating. It is shown that the C(IC) 2 HTRTX cycle provides a feasible and simple way to operate the power plant the load-follow mode with a very little loss of efficiency. (author)

  18. Safety and feasibility of chronic transvenous phrenic nerve stimulation for treatment of central sleep apnea in heart failure patients.

    Science.gov (United States)

    Zhang, Xilong; Ding, Ning; Ni, Buqing; Yang, Bing; Wang, Hong; Zhang, Shi-Jiang

    2017-03-01

    Central sleep apnea (CSA) is common in patients with heart failure (HF) and is associated with poor quality of life and prognosis. Early acute studies using transvenous phrenic nerve stimulation (PNS) to treat CSA in HF have shown a significantly reduction of CSA and improvement of key polysomnographic parameters. In this study, we evaluated the safety of and efficiency chronic transvenous PNS with an implanted neurostimulator in HF patients with CSA. This study was a prospective, nonrandomized evaluation of unilateral transvenous PNS in eight HF patients with CSA. The stimulation lead, which connected to a proprietary neurostimulator, was positioned in either the left pericardiophrenic or right brachiocephalic vein. Monitoring during implantation and 6-monthly follow-ups were performed. Six of the implanted eight patients completed the study (one was lost to follow-up; one died from pneumonia). Neither side effects nor adverse events related to stimulation occurred. During the 6-monthly follow-ups, one patient had a lead dislodgement in the first month and the lead was subsequently repositioned. No additional lead dislodgements occurred. There were no significant changes in sleep habits, appetite, bleeding or infections. Compared with the parameters before stimulator implantation, there were significant improvement in apnea-hypopnea index, central apnea index, left ventricular ejection fraction and 6-min walk distance (all P < 0.01). Use of chronic transvenous PNS appears to be safe and feasible in HF patients with CSA. Large multicenter studies are needed to confirm safety and efficacy in this population. © 2015 John Wiley & Sons Ltd.

  19. Overview of CNES-CEA joint programme on space nuclear Brayton systems

    International Nuclear Information System (INIS)

    Carre, F.; Proust, E.; Chaudourne, S.; Keirle, P.; Tilliette, Z.; Vrillon, B.

    1990-01-01

    In 1982, a cooperative programme on space nuclear power systems was initiated between the French Centre National d'Etudes Spatiales (CNES) and the Commissariat a l'Energie Atomique (CEA), to assess the feasibility, lead time, cost, competitiveness and development prospects for space nuclear power systems (SPS) in the 20 to 200 kWe range. The present three-year study phase is primarily oriented toward the assessment of various reactor candidate technologies and system design options for nuclear SPS in the 20 kWe class, which corresponds to the expected power needs of the first European space missions, anticipated to begin in 2005. This paper presents an overview of the present programme phase, with emphasis on design studies of three reference design concepts for 20 kWe turboelectric nuclear power systems selected so as to cover a wide range of reactor temperatures and corresponding technologies. The systems differ mainly in their nuclear reactors which are: the Liquid Metal Fast Breeder derivative or UO 2 /Na/Stainless steel -650 0 C; the High Temperature Gas-cooled derivative or UO 2 /direct cycle/super alloys - 850 0 C; and the UN/Li/MoRe alloy - 1120 0 C. All three systems use a Brayton cycle with recuperation for power conversion. (author)

  20. System design specification Brayton Isotope Power System (BIPS) Flight System (FS), and Ground Demonstration System (GDS)

    International Nuclear Information System (INIS)

    1976-01-01

    The system design specification for ground demonstration, development, and flight qualification of a Brayton Isotope Power System (BIPS) is presented. The requirements for both a BIPS conceptual Flight System (FS) and a Ground Demonstration System (GDS) are defined

  1. Development of a 77K Reverse-Brayton Cryocooler with Multiple Coldheads, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — RTI will design and optimize an 80 W, 77K cryocooler based on the reverse turbo Brayton cycle (RTBC) with four identical coldheads for distributed cooling. Based on...

  2. Test Results from a Direct Drive Gas Reactor Simulator Coupled to a Brayton Power Conversion Unit

    Science.gov (United States)

    Hervol, David S.; Briggs, Maxwell H.; Owen, Albert K.; Bragg-Sitton, Shannon M.; Godfroy, Thomas J.

    2010-01-01

    Component level testing of power conversion units proposed for use in fission surface power systems has typically been done using relatively simple electric heaters for thermal input. These heaters do not adequately represent the geometry or response of proposed reactors. As testing of fission surface power systems transitions from the component level to the system level it becomes necessary to more accurately replicate these reactors using reactor simulators. The Direct Drive Gas-Brayton Power Conversion Unit test activity at the NASA Glenn Research Center integrates a reactor simulator with an existing Brayton test rig. The response of the reactor simulator to a change in Brayton shaft speed is shown as well as the response of the Brayton to an insertion of reactivity, corresponding to a drum reconfiguration. The lessons learned from these tests can be used to improve the design of future reactor simulators which can be used in system level fission surface power tests.

  3. Brayton Isotope Power System, Design Integrity Checklist (BIPS-DIC)

    Energy Technology Data Exchange (ETDEWEB)

    Miller, L.G.

    1976-06-10

    A preliminary Failure Modes, Effects and Criticality Analysis (FMECA) for the BIPS Flight System (FS) was published as AiResearch Report 76-311709 dated January 12, 1976. The FMECA presented a thorough review of the conceptual BIPS FS to identify areas of concern and activities necessary to avoid premature failures. In order to assure that the actions recommended by the FMECA are effected in both the FS and the Ground Demonstration System (GDS), a checklist (the BIPS-DIC) was prepared for the probability of occurrence of those failure modes that rated highest in criticality ranking. This checklist was circulated as an attachment to AiResearch Coordination Memo No. BIPS-GDS-A0106 dated January 23, 1976. The Brayton Isotope Power System-Design Integrity Checklist (BIPS-DIC) has been revised and is presented. Additional entries have been added that reference failure modes determined to rank highest in criticality ranking. The checklist will be updated periodically.

  4. A 4 K tactical cryocooler using reverse-Brayton machines

    Science.gov (United States)

    Zagarola, M.; Cragin, K.; McCormick, J.; Hill, R.

    2017-12-01

    Superconducting electronics and spectral-spatial holography have the potential to revolutionize digital communications, but must operate at cryogenic temperatures, near 4 K. Liquid helium is undesirable for military missions due to logistics and scarcity, and commercial low temperature cryocoolers are unable to meet size, weight, power, and environmental requirements for many missions. To address this need, Creare is developing a reverse turbo-Brayton cryocooler that provides refrigeration at 4.2 K and rejects heat at 77 K to an upper-stage cryocooler or through boil-off of liquid nitrogen. The cooling system is predicted to reduce size, weight, and input power by at least an order of magnitude as compared to the current state-of-the-art 4.2 K cryocooler. For systems utilizing nitrogen boil-off, the boil-off rate is reasonable. This paper reviews the design of the cryocooler, the key components, and component test results.

  5. Mission environments for the Isotope Brayton Flight System (preliminary)

    International Nuclear Information System (INIS)

    1975-01-01

    The mission environments for the Isotope Brayton Flight Systems (IBFS) are summarized. These are based on (1) those environments established for the MHW-RTG system in the LES 8/9 and Mariner J/S and (2) engineering projections of those likely to exit for the IBFS. The pre-launch environments address transportation, storage, handling and assembly (to spacecraft) and checkout, field transportation, and launch site operations. Launch environments address the Titan IIIC and Shuttle launch vehicles. Operational mission environments address normal space temperature and meteoroide environments. Special environments that may be applicable to DOD missions are not included. Accident environments address explosion and fire for the Titan IIIC and the Shuttle, reentry, earth impact and post impact

  6. Design and fabrication of the Mini-Brayton Recuperator (MBR)

    Science.gov (United States)

    Killackey, J. J.; Graves, R.; Mosinskis, G.

    1978-01-01

    Development of a recuperator for a 2.0 kW closed Brayton space power system is described. The plate-fin heat exchanger is fabricated entirely from Hastelloy X and is designed for 10 years continuous operation at 1000 K (1300 F) with a Xenon-helium working fluid. Special design provisions assure uniform flow distribution, crucial for meeting 0.975 temperature effectiveness. Low-cycle fatigue, resulting from repeated startup and shutdown cycles, was identified as the most critical structural design problem. It is predicted that the unit has a minimum fatigue life of 220 cycles. This is in excess of the BIPS requirement of 100 cycles. Heat transfer performance and thermal cycle testing with air, using a prototype unit, verified that all design objectives can be met.

  7. Calculation principles of humid air in a reversed Brayton cycle

    Energy Technology Data Exchange (ETDEWEB)

    Backman, J [Lappeenranta Univ. of Technology (Finland). Dept. of Energy Technology

    1998-12-31

    The article presents a calculation method for reversed Brayton cycle that uses humid air as working medium. The reversed Brayton cycle can be employed as an air dryer, a heat pump or a refrigerating machine. In this research the use of humid air as a working fluid has an environmental advantage, as well. In this method especially the expansion process in the turbine is important because of the condensation of the water vapour in the humid air. This physical phenomena can have significant effects on the level of performance of the application. The expansion process differs physically from the compression process, when the water vapour in the humid air begins to condensate. In the thermodynamic equilibrium of the flow, the water vapour pressure in humid air cannot exceed the pressure of saturated water vapour in corresponding temperature. Expansion calculation during operation around the saturation zone is based on a quasistatic expansion, in which the system after the turbine is in thermodynamical equilibrium. The state parameters are at every moment defined by the equation of state, and there is no supercooling in the vapour. Following simplifications are used in the calculations: The system is assumed to be adiabatic. This means that there is no heat transfer to the surroundings. This is a common practice, when the temperature differences are moderate as here; The power of the cooling is omitted. The cooling construction is very dependent on the machine and the distribution of the losses; The flow is assumed to be one-dimensional, steady-state and homogenous. The water vapour condensing in the turbine can cause errors, but the errors are mainly included in the efficiency calculation. (author) 11 refs.

  8. Calculation principles of humid air in a reversed Brayton cycle

    Energy Technology Data Exchange (ETDEWEB)

    Backman, J. [Lappeenranta Univ. of Technology (Finland). Dept. of Energy Technology

    1997-12-31

    The article presents a calculation method for reversed Brayton cycle that uses humid air as working medium. The reversed Brayton cycle can be employed as an air dryer, a heat pump or a refrigerating machine. In this research the use of humid air as a working fluid has an environmental advantage, as well. In this method especially the expansion process in the turbine is important because of the condensation of the water vapour in the humid air. This physical phenomena can have significant effects on the level of performance of the application. The expansion process differs physically from the compression process, when the water vapour in the humid air begins to condensate. In the thermodynamic equilibrium of the flow, the water vapour pressure in humid air cannot exceed the pressure of saturated water vapour in corresponding temperature. Expansion calculation during operation around the saturation zone is based on a quasistatic expansion, in which the system after the turbine is in thermodynamical equilibrium. The state parameters are at every moment defined by the equation of state, and there is no supercooling in the vapour. Following simplifications are used in the calculations: The system is assumed to be adiabatic. This means that there is no heat transfer to the surroundings. This is a common practice, when the temperature differences are moderate as here; The power of the cooling is omitted. The cooling construction is very dependent on the machine and the distribution of the losses; The flow is assumed to be one-dimensional, steady-state and homogenous. The water vapour condensing in the turbine can cause errors, but the errors are mainly included in the efficiency calculation. (author) 11 refs.

  9. Brayton rotating units for space reactor power systems

    Energy Technology Data Exchange (ETDEWEB)

    Gallo, Bruno M.; El-Genk, Mohamed S. [Institute for Space and Nuclear Power Studies and Chemical and Nuclear Engineering Dept., The Univ. of New Mexico, Albuquerque, NM 87131 (United States)

    2009-09-15

    Designs and analyses models of centrifugal-flow compressor and radial-inflow turbine of 40.8kW{sub e} Brayton Rotating Units (BRUs) are developed for 15 and 40 g/mole He-Xe working fluids. Also presented are the performance results of a space power system with segmented, gas cooled fission reactor heat source and three Closed Brayton Cycle loops, each with a separate BRU. The calculated performance parameters of the BRUs and the reactor power system are for shaft rotational speed of 30-55 krpm, reactor thermal power of 120-471kW{sub th}, and turbine inlet temperature of 900-1149 K. With 40 g/mole He-Xe, a power system peak thermal efficiency of 26% is achieved at rotation speed of 45 krpm, compressor and turbine inlet temperatures of 400 and 1149 K and 0.93 MPa at exit of the compressor. The corresponding system electric power is 122.4kW{sub e}, working fluid flow rate is 1.85 kg/s and the pressure ratio and polytropic efficiency are 1.5% and 86.3% for the compressor and 1.42% and 94.1% for the turbine. For the same nominal electrical power of 122.4kW{sub e}, decreasing the molecular weight of the working fluid (15 g/mole) decreases its flow rate to 1.03 kg/s and increases the system pressure to 1.2 MPa. (author)

  10. Parametric Investigation of Brayton Cycle for High Temperature Gas-Cooled Reactor

    International Nuclear Information System (INIS)

    Chang Oh

    2004-01-01

    The Idaho National Engineering and Environmental Laboratory (INEEL) is investigating a Brayton cycle efficiency improvement on a high temperature gas-cooled reactor (HTGR) as part of Generation-IV nuclear engineering research initiative. In this project, we are investigating helium Brayton cycles for the secondary side of an indirect energy conversion system. Ultimately we will investigate the improvement of the Brayton cycle using other fluids, such as supercritical carbon dioxide. Prior to the cycle improvement study, we established a number of baseline cases for the helium indirect Brayton cycle. These cases look at both single-shaft and multiple-shaft turbomachinery. The baseline cases are based on a 250 MW thermal pebble bed HTGR. The results from this study are applicable to other reactor concepts such as a very high temperature gas-cooled reactor (VHTR), fast gas-cooled reactor (FGR), supercritical water reactor (SWR), and others. In this study, we are using the HYSYS computer code for optimization of the helium Brayton cycle. Besides the HYSYS process optimization, we performed parametric study to see the effect of important parameters on the cycle efficiency. For these parametric calculations, we use a cycle efficiency model that was developed based on the Visual Basic computer language. As a part of this study we are currently investigated single-shaft vs. multiple shaft arrangement for cycle efficiency and comparison, which will be published in the next paper. The ultimate goal of this study is to use supercritical carbon dioxide for the HTGR power conversion loop in order to improve the cycle efficiency to values great than that of the helium Brayton cycle. This paper includes preliminary calculations of the steady state overall Brayton cycle efficiency based on the pebble bed reactor reference design (helium used as the working fluid) and compares those results with an initial calculation of a CO2 Brayton cycle

  11. Randomized controlled trial of Family Nurture Intervention in the NICU: assessments of length of stay, feasibility and safety.

    Science.gov (United States)

    Welch, Martha G; Hofer, Myron A; Stark, Raymond I; Andrews, Howard F; Austin, Judy; Glickstein, Sara B; Ludwig, Robert J; Myers, Michael M

    2013-09-24

    While survival rates for preterm infants have increased, the risk for adverse long-term neurodevelopmental and behavioral outcomes remains very high. In response to the need for novel, evidence-based interventions that prevent such outcomes, we have assessed Family Nurture Intervention (FNI), a novel dual mother-infant intervention implemented while the infant is in the Neonatal Intensive Care Unit (NICU). Here, we report the first trial results, including the primary outcome measure, length of stay in the NICU and, the feasibility and safety of its implementation in a high acuity level IV NICU. The FNI trial is a single center, parallel-group, randomized controlled trial at Morgan Stanley Children's Hospital for mothers and their singleton or twin infants of 26-34 weeks gestation. Families were randomized to standard care (SC) or (FNI). FNI was implemented by nurture specialists trained to facilitate affective communication between mother and infant during specified calming interactions. These interactions included scent cloth exchange, sustained touch, vocal soothing and eye contact, wrapped or skin-to-skin holding, plus family-based support interactions. A total of 826 infants born between 26 and 34 weeks during the 3.5 year study period were admitted to the NICU. After infant and mother screening plus exclusion due to circumstances that prevented the family from participating, 373 infants were eligible for the study. Of these, we were unable to schedule a consent meeting with 56, and consent was withheld by 165. Consent was obtained for 150 infants from 115 families. The infants were block randomized to groups of N = 78, FNI and N = 72, SC. Sixteen (9.6%) of the randomized infants did not complete the study to home discharge, 7% of those randomized to SC and 12% of FNI infants. Mothers in the intervention group engaged in 3 to 4 facilitated one- to two-hour sessions/week. Intent to treat analyses revealed no significant difference between groups in

  12. Assessing the potential of hybrid fossil–solar thermal plants for energy policy making: Brayton cycles

    International Nuclear Information System (INIS)

    Bernardos, Eva; López, Ignacio; Rodríguez, Javier; Abánades, Alberto

    2013-01-01

    This paper proposes a first study in-depth of solar–fossil hybridization from a general perspective. It develops a set of useful parameters for analyzing and comparing hybrid plants, it studies the case of hybridizing Brayton cycles with current solar technologies and shows a tentative extrapolation of the results to integrated combined cycle systems (ISCSS). In particular, three points have been analyzed: the technical requirements for solar technologies to be hybridized with Brayton cycles, the temperatures and pressures at which hybridization would produce maximum power per unit of fossil fuel, and their mapping to current solar technologies and Brayton cycles. Major conclusions are that a hybrid plant works in optimum conditions which are not equal to those of the solar or power blocks considered independently, and that hybridizing at the Brayton cycle of a combined cycle could be energetically advantageous. -- Highlights: •We model a generic solar–fossil hybrid Brayton cycle. •We calculate the operating conditions for maximum ratio power/fuel consumption. •Best hybrid plant conditions are not the same as solar or power blocks separately. •We study potential for hybridization with current solar technologies. •Hybridization at the Brayton in a combined cycle may achieve high power/fuel ratio

  13. Feasibility and Safety of Transradial Arterial Approach for Simultaneous Right and Left Vertebral Artery Angiographic Studies and Stenting

    International Nuclear Information System (INIS)

    Yip, H.-K.; Youssef, Ali A.; Chang, W.-N.; Lu, C.-H.; Yang, C.-H.; Chen, S.-M.; Wu, C.-J.

    2007-01-01

    Objectives. This study investigated whether the transradial artery (TRA) approach using a 6-French (F) Kimny guiding catheter for right vertebral artery (VA) angiographic study and stenting is safe and effective for patients with significant VA stenosis. Background. The TRA approach is commonly performed worldwide for both diagnostic cardiac catheterization and catheter-based coronary intervention. However, to our knowledge, the safety and feasibility of left and right VA angiographic study and stenting, in the same procedure, using the TRA approach for patients with brain ischemia have not been reported. Methods. The study included 24 consecutive patients (22 male, 2 female; age, 63-78 years). Indications for VA angiographic study and stenting were (1) prior stroke or symptoms related to vertebrobasilar ischemia and (2) an asymptomatic but vertebral angiographic finding of severe stenosis (>70%). A combination of the ipsilateral and retrograde-engagement technique, which involved a looping 6-F Kimny guiding catheter, was utilized for VA angiographic study. For VA stenting, an ipsilateral TRA approach with either a Kimny guiding catheter or a left internal mammary artery guiding catheter was utilized in 22 patients and retrograde-engagement technique in 2 patients. Results. A technically successful procedure was achieved in all patients, including left VA stenting in 15 patients and right VA stenting in 9 patients. The mean time for stenting (from engagement to stent deployment) was 12.7 min. There were no vascular complications or mortality. However, one patient suffered from a transient ischemic attack that resolved within 3 h. Conclusion. We conclude that TRA access for both VA angiographic study and VA stenting is safe and effective, and provides a simple and useful clinical tool for patients unsuited for femoral arterial access

  14. Feasibility and safety of adenosine cardiovascular magnetic resonance in patients with MR conditional pacemaker systems at 1.5 Tesla.

    Science.gov (United States)

    Klein-Wiele, Oliver; Garmer, Marietta; Urbien, Rhyan; Busch, Martin; Kara, Kaffer; Mateiescu, Serban; Grönemeyer, Dietrich; Schulte-Hermes, Michael; Garbrecht, Marc; Hailer, Birgit

    2015-12-22

    Cardiovascular Magnetic Resonance (CMR) with adenosine stress is a valuable diagnostic tool in coronary artery disease (CAD). However, despite the development of MR conditional pacemakers CMR is not yet established in clinical routine for pacemaker patients with known or suspected CAD. A possible reason is that adenosine stress perfusion for ischemia detection in CMR has not been studied in patients with cardiac conduction disease requiring pacemaker therapy. Other than under resting conditions it is unclear whether MR safe pacing modes (paused pacing or asynchronous mode) can be applied safely because the effect of adenosine on heart rate is not precisely known in this entity of patients. We investigate for the first time feasibility and safety of adenosine stress CMR in pacemaker patients in clinical routine and evaluate a pacing protocol that considers heart rate changes under adenosine. We retrospectively analyzed CMR scans of 24 consecutive patients with MR conditional pacemakers (mean age 72.1 ± 11.0 years) who underwent CMR in clinical routine for the evaluation of known or suspected CAD. MR protocol included cine imaging, adenosine stress perfusion and late gadolinium enhancement. Pacemaker indications were sinus node dysfunction (n = 18) and second or third degree AV block (n = 6). Under a pacing protocol intended to avoid competitive pacing on the one hand and bradycardia due to AV block on the other no arrhythmia occurred. Pacemaker stimulation was paused to prevent competitive pacing in sinus node dysfunction with resting heart rate >45 bpm. Sympatho-excitatory effect of adenosine led to a significant acceleration of heart rate by 12.3 ± 8.3 bpm (p pacemakers. Heart rate response to adenosine has to be considered for the choice of pacing modes during CMR.

  15. Morphometric analysis of the cervical facets and the feasibility, safety, and effectiveness of Goel inter-facet spacer distraction technique

    Directory of Open Access Journals (Sweden)

    Abhidha Shah

    2014-01-01

    Full Text Available Aim: Quantitative anatomy of the facets of the sub-axial cervical spine was performed. The purpose of the evaluation was to determine the feasibility of insertion of Goel inter-facetal articular spacers in the sub-axial cervical spine. Only few studies detailing the morphometry of the facets are available in the literature. Materials and Methods: Ten cervical vertebrae from C3 to C7 with a total of 20 facets were evaluated by the author. The anatomic parameters studied were the height, width, thickness, shape, orientation, and inclination of each of the superior and inferior facets. The alterations in a number of intervertebral segmental distances were measured before and after spacer insertion. The distance of the inferior facet from the foramen tranversarium, spinal canal, and neural foramina was measured to assess safety of spacer insertion with respect to the vertebral artery and neural structures. Results: The height, width and thickness of the superior facets from C3 to C7 ranged from 6 to 12 mm, 8 to 12 mm, and 2.5 to 6 mm, respectively. The inferior facets had an average height of 10.5 mm, average width of 11.2 mm and average thickness of 3.5 mm. The inclination of the superior facets with respect to the transverse plane ranged from 22° to 45° and that of the inferior facets ranged from 29° to 53°. The distance of the anterior margin of the inferior facet from the posterior border of the foramen transversium ranged from 5 to 7 mm. This distance was maximum at C3 level, then decreased at C4 and remained constant from C5 to C7. Conclusion: This anatomic evaluation aided in understanding the morphology of the cervical facets and the suitability of the cervical facetal articular cavity for insertion of spacers.

  16. Safety and feasibility of pressurized intraperitoneal aerosol chemotherapy (PIPAC) associated with systemic chemotherapy: an innovative approach to treat peritoneal carcinomatosis.

    Science.gov (United States)

    Robella, Manuela; Vaira, Marco; De Simone, Michele

    2016-04-29

    Pressurized intraperitoneal aerosol chemotherapy (PIPAC) is a new treatment that applies chemotherapeutic drugs into the peritoneal cavity as an aerosol under pressure. It improves local bioavailability of chemotherapeutic drugs as compared with conventional intraperitoneal chemotherapy. It has been proved to be safe and feasible if performed as an exclusive treatment in patients affected by peritoneal carcinomatosis. The first results in patients treated with PIPAC associated with systemic chemotherapy are presented. Between June 2015 and February 2016, 57 PIPAC applications with oxaliplatin or cisplatin + doxorubicin every 6 weeks at 37 °C and 12 mmHg for 30 min were performed. Forty PIPAC procedures performed in 14 patients were included in this study; thirteen patients were undergoing systemic chemotherapy with a wash-out interval of at least 2 weeks before and 1 week after each PIPAC. Safety, tolerability, and postoperative complications were assessed by collection of adverse events according to the Common Terminology Criteria for Adverse Events (CTCAE) 2. Forty PIPAC administrations were performed in 14 patients with no major perioperative complications. CTCAE grades 1 and 2 were observed after six and eight procedures, respectively, for abdominal pain and nausea. Renal and hepatic functions were not impaired; no cumulative renal toxicity was observed after repeated PIPAC procedures in association with systemic chemotherapy. These preliminary data show that the association of PIPAC and systemic chemotherapy does not induce significant hepatic and renal toxicity. It allows inclusion of patients with extraperitoneal disease or at a high risk of developing it. Further studies are needed to assess whether this combination therapy could become part of the standard treatment for peritoneal carcinomatosis.

  17. Feasibility, safety and effectiveness of combining home based malaria management and seasonal malaria chemoprevention in children less than 10 years in Senegal

    DEFF Research Database (Denmark)

    Tine, Roger C K; Ndour, Cheikh T; Faye, Babacar

    2014-01-01

    Home-based management of malaria (HMM) may improve access to diagnostic testing and treatment with artemisinin combination therapy (ACT). In the Sahel region, seasonal malaria chemoprevention (SMC) is now recommended for the prevention of malaria in children. It is likely that combinations...... of antimalarial interventions can reduce the malaria burden. This study assessed the feasibility, effectiveness and safety of combining SMC and HMM delivered by community health workers (CHWs)....

  18. Long-term safety and feasibility of three-vessel multimodality intravascular imaging in patients with ST-elevation myocardial infarction

    DEFF Research Database (Denmark)

    Taniwaki, Masanori; Radu, Maria D; Garcia-Garcia, Hector M

    2015-01-01

    We assessed the feasibility and the procedural and long-term safety of intracoronary (i.c) imaging for documentary purposes with optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in patients with acute ST-elevation myocardial infarction (STEMI) undergoing primary PCI in the s......We assessed the feasibility and the procedural and long-term safety of intracoronary (i.c) imaging for documentary purposes with optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in patients with acute ST-elevation myocardial infarction (STEMI) undergoing primary PCI...... in the setting of IBIS-4 study. IBIS4 (NCT00962416) is a prospective cohort study conducted at five European centers including 103 STEMI patients who underwent serial three-vessel coronary imaging during primary PCI and at 13 months. The feasibility parameter was successful imaging, defined as the number...... of pullbacks suitable for analysis. Safety parameters included the frequency of peri-procedural complications, and major adverse cardiac events (MACE), a composite of cardiac death, myocardial infarction (MI) and any clinically-indicated revascularization at 2 years. Clinical outcomes were compared...

  19. Safety and feasibility of atrial fibrillation ablation using Amigo® system versus manual approach: A pilot study

    Directory of Open Access Journals (Sweden)

    Antonio Scarà

    2018-03-01

    Full Text Available Background: The Amigo® Remote Catheter System is a relatively new robotic system for catheter navigation. This study compared feasibility and safety using Amigo (RCM versus manual catheter manipulation (MCM to treat paroxysmal atrial fibrillation (PAF. Contact force (CF and force-time integral (FTI values obtained during pulmonary vein isolation (PVI ablation were compared. Methods: Forty patients were randomly selected for either RCM (20 or MCM (20. All were studied with the Thermocool® SmartTouch® force-sensing catheter (STc. Contact Force (CF, Force Time Integral (FTI and procedure-related data, were measured/stored in the CARTO®3. Results: All cases achieved complete PVI without major complications. Mean CF was significantly higher in the RCM group (13.3 ± 7.7 g in RCM vs. 12.04 ± 7.42 g in MCM p < 0.001, as was overall mean FTI (425.6 gs ± 199.6 gs with RCM and 407.5 gs ± 288.0 gs in MCM (p = 0.007 and was more likely to fall into the optimal FTI range (400-1000 using RCM (66.1% versus 49.1%, p < 0.001. FTI was significantly more likely to fall within the optimal range in each PV, as was CF within its optimal range in the right PVs, but trended higher in the left PVs. Freedom from atrial tachyarrhythmia was 90.0% for the RCM and 70.0% for the MCM group (p = 0,12 at 540 days follow-up. Conclusions: This pilot study suggests that use of the Amigo RCM system, with STc catheter, seems to be safe and effective for PVI ablation in paroxysmal AF patients. A not statistically significant favorable trend was observed for RCM in term of AF-free survival. Keywords: Atrial fibrillation, Catheter ablation, Remote robotic ablation

  20. Feasibility of a computer-delivered driver safety behavior screening and intervention program initiated during an emergency department visit.

    Science.gov (United States)

    Murphy, Mary; Smith, Lucia; Palma, Anton; Lounsbury, David; Bijur, Polly; Chambers, Paul; Gallagher, E John

    2013-01-01

    Injuries from motor vehicle crashes are a significant public health problem. The emergency department (ED) provides a setting that may be used to screen for behaviors that increase risk for motor vehicle crashes and provide brief interventions to people who might otherwise not have access to screening and intervention. The purpose of the present study was to (1) assess the feasibility of using a computer-assisted screening program to educate ED patients about risky driving behaviors, (2) evaluate patient acceptance of the computer-based traffic safety educational intervention during an ED visit, and (3) assess postintervention changes in risky driving behaviors. Pre/posteducational intervention involving medically stable adult ED patients in a large urban academic ED serving over 100,000 patients annually. Patients completed a self-administered, computer-based program that queried patients on risky driving behaviors (texting, talking, and other forms of distracted driving) and alcohol use. The computer provided patients with educational information on the dangers of these behaviors and data were collected on patient satisfaction with the program. Staff called patients 1 month post-ED visit for a repeat query. One hundred forty-nine patients participated, and 111 completed 1-month follow up (75%); the mean age was 39 (range: 21-70), 59 percent were Hispanic, and 52 percent were male. Ninety-seven percent of patients reported that the program was easy to use and that they were comfortable receiving this education via computer during their ED visit. All driving behaviors significantly decreased in comparison to baseline with the following reductions reported: talking on the phone, 30 percent; aggressive driving, 30 percent; texting while driving, 19 percent; drowsy driving, 16 percent; driving while multitasking, 12 percent; and drinking and driving, 9 percent. Overall, patients were very satisfied receiving educational information about these behaviors via computer

  1. Environmental, Safety, and Health Plan for the remedial investigation/feasibility study at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Revision 1, Environmental Restoration Program

    Energy Technology Data Exchange (ETDEWEB)

    Davis, C. M.; El-Messidi, O. E.; Cowser, D. K.; Kannard, J. R.; Carvin, R. T.; Will, III, A. S.; Clark, Jr., C.; Garland, S. B.

    1993-05-01

    This Environmental, Safety, and Health (ES&H) Plan presents the concepts and methodologies to be followed during the remedial investigation/feasibility study (RI/FS) for Oak Ridge National Laboratory (ORNL) to protect the health and safety of employees, the public, and the environment. This ES&H Plan acts as a management extension for ORNL and Martin Marietta Energy Systems, Inc. (Energy Systems) to direct and control implementation of the project ES&H program. The subsections that follow describe the program philosophy, requirements, quality assurance measures, and methods for applying the ES&H program to individual waste area grouping (WAG) remedial investigations. Hazardous work permits (HWPs) will be used to provide task-specific health and safety requirements.

  2. Strategy for a consistent selection of radionuclide migration parameters for the Belgian safety and feasibility case-1

    International Nuclear Information System (INIS)

    Bruggeman, C.; Maes, N.; Salah, S.; Brassinnes, S.; Van Geet, M.

    2010-01-01

    Document available in extended abstract form only. The purpose of this presentation is to describe the strategy for the selection of retention and migration parameters for safety-relevant nuclides that was developed in the framework of the Belgian Safety and Feasibility Case SFC-1. A geochemical database containing state-of-the-art retention and migration parameters of all safety-relevant radionuclides, is ideally based on a thermodynamic understanding and an ability to accurately describe the geochemical and transport behaviour of all these radionuclides under the geochemical conditions that are considered for a reference host formation. In Belgium, this reference formation is Boom Clay. The parameters will be used in Performance Assessment (PA) calculations, and therefore must also be adapted to PA models. Since these models currently use only a four parameters for every radionuclide, the whole geochemical and transport behaviour must be comprised to a very limited parameter set that describe on the one hand chemical retention within the Boom Clay formation, and on the other hand transport through the Boom Clay formation. Chemical retention considers two concepts: 1) a concentration limit (S), which represents the mobile concentration of a nuclide present in the aqueous phase under undisturbed far field Boom Clay conditions; 2) a retardation (R/Kd) factor, which represents the uptake of a mobile nuclide by the inorganic and organic phases present in the Boom Clay formation. For mobility/migration two additional concepts are introduced: 3) the diffusion accessible porosity (η), which is the total physical space available for transport of a nuclide. The maximum value of η is limited by the water content of the formation; 4) the pore diffusion coefficient (Dp), which represents the transport velocity of a nuclide in a diffusion-dominated system. Within the framework of SFC-1, primary focus is laid on the compilation of parameter ranges, instead of individual &apos

  3. Feasibility, safety, and potential demand of emergent brain magnetic resonance imaging of patients with cardiac implantable electronic devices

    Directory of Open Access Journals (Sweden)

    Maki Ono

    2017-10-01

    Conclusions: Our study found the potential demand of brain MRI of patients with CIEDs in emergency situations compared with scheduled scanning, which was shown to be feasible and safe for the diagnosis and treatment of an acute stroke.

  4. A treatment of thermal efficiency improvement in the Brayton cycle

    International Nuclear Information System (INIS)

    Fujii, Terushige; Akagawa, Koji; Nakanishi, Shigeyasu; Inoue, Kiyoshi; Ishigai, Seikan.

    1982-01-01

    So far, as the working fluid for power-generating plants, mainly water and air (combustion gas) have been used. In this study, in regeneration and isothermal compression processes being considered as the means for the efficiency improvement in Brayton cycle, the investigation of equivalent graphical presentation method with T-S diagrams, the introduction of the new characteristic number expressing the possibility of thermal efficiency improvement by regeneration, and the investigation of the effect of the difference of working fluid on thermal efficiency were carried out. Next, as the cycle approximately realizing isothermal compression process with condensation process, the super-critical pressure cycle with liquid phase compression was rated, and four working fluids, NH 3 , SO 2 , CO 2 and H 2 O were examined as perfect gas and real gas. The advantage of CO 2 regeneration for the thermal efficiency improvement was clarified by using the dimensionless characteristic number. The graphical presentation of effective work, the thermal efficiency improvement by regeneration, the thermal efficiency improvement by making compression process isothermal, the effect on thermal efficiency due to various factors and working fluids, the characteristic number by regeneration, and the application to real working fluids are reported. (Kako, I.)

  5. Preliminary closed Brayton cycle study for a space reactor application

    International Nuclear Information System (INIS)

    Guimaraes, Lamartine Nogueira Frutuoso; Carvalho, Ricardo Pinto de; Camillo, Giannino Ponchio

    2007-01-01

    The Nuclear Energy Division (ENU) of the Institute for Advanced Studies (IEAv) has started a preliminary design study for a Closed Brayton Cycle Loop (CBCL) aimed at a space reactor application. The main objectives of the study are to establish a starting concept for the CBCL components specifications, and to develop a demonstrative simulator of CBCL in nominal operation conditions. The ENU/IEAv preliminary design study is developing the CBCL around the NOELLE 60290 turbo machine. The actual nuclear reactor study is being conducted independently. Because of that, a conventional heat source is being used for the CBCL, in this preliminary design phase. This paper describes the steady state simulator of the CBCL operating with NOELLE 60290 turbo machine. In principle, several gases are being considered as working fluid, as for instance: air, helium, nitrogen, CO2 and gas mixtures such as helium and xenon. At this moment the simulator is running with Helium as the working fluid. Simplified models of heat and mass transfer are being developed to simulate thermal components. Future efforts will focus on keeping track of the modifications being implemented at the NOELLE 60290 turbo machine in order to build the CBCL. (author)

  6. Preliminary closed Brayton cycle study for a space reactor application

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Lamartine Nogueira Frutuoso; Carvalho, Ricardo Pinto de [Institute for Advanced Studies, Sao Jose dos Campos, SP (Brazil)]. E-mail: guimarae@ieav.cta.br; Camillo, Giannino Ponchio [Instituto Tecnologico de Aeronautica (ITA), Sao Jose dos Campos, SP (Brazil)]. E-mail: gianninocamillo@gmail.com

    2007-07-01

    The Nuclear Energy Division (ENU) of the Institute for Advanced Studies (IEAv) has started a preliminary design study for a Closed Brayton Cycle Loop (CBCL) aimed at a space reactor application. The main objectives of the study are to establish a starting concept for the CBCL components specifications, and to develop a demonstrative simulator of CBCL in nominal operation conditions. The ENU/IEAv preliminary design study is developing the CBCL around the NOELLE 60290 turbo machine. The actual nuclear reactor study is being conducted independently. Because of that, a conventional heat source is being used for the CBCL, in this preliminary design phase. This paper describes the steady state simulator of the CBCL operating with NOELLE 60290 turbo machine. In principle, several gases are being considered as working fluid, as for instance: air, helium, nitrogen, CO2 and gas mixtures such as helium and xenon. At this moment the simulator is running with Helium as the working fluid. Simplified models of heat and mass transfer are being developed to simulate thermal components. Future efforts will focus on keeping track of the modifications being implemented at the NOELLE 60290 turbo machine in order to build the CBCL. (author)

  7. Thermo-economic performance of HTGR Brayton power cycles

    International Nuclear Information System (INIS)

    Linares, J. L.; Herranz, L. E.; Moratilla, B. Y.; Fernandez-Perez, A.

    2008-01-01

    High temperature reached in High and Very High Temperature Reactors (VHTRs) results in thermal efficiencies substantially higher than those of actual nuclear power plants. A number of studies mainly driven by achieving optimum thermal performance have explored several layout. However, economic assessments of cycle power configurations for innovative systems, although necessarily uncertain at this time, may bring valuable information in relative terms concerning power cycle optimization. This paper investigates the thermal and economic performance direct Brayton cycles. Based on the available parameters and settings of different designs of HTGR power plants (GTHTR-300 and PBMR) and using the first and second laws of thermodynamics, the effects of compressor inter-cooling and of the compressor-turbine arrangement (i.e., single vs. multiple axes) on thermal efficiency have been estimated. The economic analysis has been based on the El-Sayed methodology and on the indirect derivation of the reactor capital investment. The results of the study suggest that a 1-axis inter-cooled power cycle has a similar thermal performance to the 3-axes one (around 50%) and, what's more, it is substantially less taxed. A sensitivity study allowed assessing the potential impact of optimizing several variables on cycle performance. Further than that, the cycle components costs have been estimated and compared. (authors)

  8. Study of various Brayton cycle designs for small modular sodium-cooled fast reactor

    International Nuclear Information System (INIS)

    Ahn, Yoonhan; Lee, Jeong Ik

    2014-01-01

    Highlights: • Application of closed Brayton cycle for small and medium sized SFRs is reviewed. • S-CO 2 , helium and nitrogen cycle designs for small modular SFR applications are analyzed and compared in terms of cycle efficiency, component performance and physical size. • Several new layouts for each Brayton cycle are suggested to simplify the turbomachinery designs. • S-CO 2 cycle design shows the best efficiency and compact size compared to other Brayton cycles. - Abstract: Many previous sodium cooled fast reactors (SFRs) adopted steam Rankine cycle as the power conversion system. However, the concern of sodium water reaction has been one of the major design issues of a SFR system. As an alternative to the steam Rankine cycle, several closed Brayton cycles including supercritical CO 2 cycle, helium cycle and nitrogen cycle have been suggested recently. In this paper, these alternative gas Brayton cycles will be compared to each other in terms of cycle performance and physical size for small modular SFR application. Several new layouts are suggested for each fluid while considering the turbomachinery design and the total system volume

  9. A systematic review and meta-analysis of the safety, feasibility and effect of exercise in women with stage II+ breast cancer.

    Science.gov (United States)

    Singh, Ben; Spence, Rosalind R; Steele, Megan L; Sandler, Carolina X; Peake, Jonathan M; Hayes, Sandra C

    2018-05-03

    To systematically evaluate the safety, feasibility and effect of exercise among women with stage II+ breast cancer. CINAHL, Cochrane, Ebscohost, MEDLINE, Pubmed, ProQuest Health and Medical Complete, ProQuest Nursing and Allied Health Source, Science Direct and SPORTDiscus were searched for articles published prior to March 1, 2017. Randomised, controlled, exercise trials involving at least 50% of women diagnosed with stage II+ breast cancer were included. Risk of bias was assessed and adverse event severity was classified using the Common Terminology Criteria. Feasibility was evaluated by computing median (range) recruitment, withdrawal and adherence rates. Meta-analyses were performed to evaluate exercise safety and effects on health outcomes only. The influence of intervention characteristics (mode, supervision, duration and timing) on exercise outcomes were also explored. There were no differences in adverse events between exercise and usual care (risk difference: feasibility outcomes were similar, irrespective of exercise mode, supervision, duration, or timing. Effects of exercise for quality of life, fitness, fatigue, strength, anxiety, depression, body mass index and waist circumference compared with usual care were significant (standardised mean difference range: 0.17-0.77, pfeasibility and effects of exercise for those with stage II+ breast cancer, suggesting that national and international exercise guidelines appear generalizable to women with local, regional and distant breast cancer. Copyright © 2018. Published by Elsevier Inc.

  10. Preliminary Failure Modes, Effects and Criticality Analysis (FMECA) of the conceptual Brayton Isotope Power System (BIPS) Flight System

    International Nuclear Information System (INIS)

    Miller, L.G.

    1976-01-01

    A failure modes, effects and criticality analysis (FMECA) was made of the Brayton Isotope Power System Flight System (BIPS-FS) as presently conceived. The components analyzed include: Mini-BRU; Heat Source Assembly (HSA); Mini-Brayton Recuperator (MBR); Space Radiator; Ducts and Bellows, Insulation System; Controls; and Isotope Heat Source (IHS)

  11. Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an advisory group meeting

    International Nuclear Information System (INIS)

    1996-12-01

    The meeting provided an overview of the key issues on passive safety. Technical problems which may affect future deployment, and the operating experience of passive systems and components, as well as, definitions of passive safety terms, were discussed. Advantages and disadvantages of passive systems were also highlighted. The philosophy behind different passive safety systems was presented and the range of possibility between fully passive and fully active systems was discussed. Refs, figs, tabs

  12. Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an advisory group meeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    The meeting provided an overview of the key issues on passive safety. Technical problems which may affect future deployment, and the operating experience of passive systems and components, as well as, definitions of passive safety terms, were discussed. Advantages and disadvantages of passive systems were also highlighted. The philosophy behind different passive safety systems was presented and the range of possibility between fully passive and fully active systems was discussed. Refs, figs, tabs.

  13. The feasibility study on supercritical methane Recuperated Brayton Cycle for waste heat recovery

    KAUST Repository

    Dyuisenakhmetov, Aibolat

    2017-01-01

    solar power. RBC’s compactness and the ease at which it can be integrated into existent power plants for waste heat recovery require few modifications. Methane, carbon dioxide and trifluoromethane are analyzed as possible working fluids. This work shows

  14. First series of total robotic hysterectomy (TRH) using new integrated table motion for the da Vinci Xi: feasibility, safety and efficacy.

    Science.gov (United States)

    Giannini, Andrea; Russo, Eleonora; Mannella, Paolo; Palla, Giulia; Pisaneschi, Silvia; Cecchi, Elena; Maremmani, Michele; Morelli, Luca; Perutelli, Alessandra; Cela, Vito; Melfi, Franca; Simoncini, Tommaso

    2017-08-01

    To present the first case series of total robotic hysterectomy (TRH), using integrated table motion (ITM), which is a new feature comprising a unique operating table by Trumpf Medical that communicates wirelessly with the da Vinci Xi surgical system. ITM has been specifically developed to improve multiquadrant robotic surgery such as that conducted in colorectal surgery. Between May and October 2015, a prospective post-market study was conducted on ITM in the EU in 40 cases from different specialties. The gynecological study group comprised 12 patients. Primary endpoints were ITM feasibility, safety and efficacy. Ten patients underwent TRH. Mean number of ITM moves was three during TRH; there were 31 instances of table moves in the ten procedures. Twenty-eight of 31 ITM moves were made to gain internal exposure. The endoscope remained inserted during 29 of the 31 table movements (94%), while the instruments remained inserted during 27 of the 31 moves (87%). No external instrument collisions or other problems related to the operating table were noted. There were no ITM safety-related observations and no adverse events. This preliminary study demonstrated the feasibility, safety and efficacy of ITM for the da Vinci Xi surgical system in TRH. ITM was safe, with no adverse events related to its use. Further studies will be useful to define the real role and potential benefit of ITM in gynecological surgery.

  15. Dry Air Cooler Modeling for Supercritical Carbon Dioxide Brayton Cycle Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Moisseytsev, A. [Argonne National Lab. (ANL), Argonne, IL (United States); Sienicki, J. J. [Argonne National Lab. (ANL), Argonne, IL (United States); Lv, Q. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-07-28

    Modeling for commercially available and cost effective dry air coolers such as those manufactured by Harsco Industries has been implemented in the Argonne National Laboratory Plant Dynamics Code for system level dynamic analysis of supercritical carbon dioxide (sCO2) Brayton cycles. The modeling can now be utilized to optimize and simulate sCO2 Brayton cycles with dry air cooling whereby heat is rejected directly to the atmospheric heat sink without the need for cooling towers that require makeup water for evaporative losses. It has sometimes been stated that a benefit of the sCO2 Brayton cycle is that it enables dry air cooling implying that the Rankine steam cycle does not. A preliminary and simple examination of a Rankine superheated steam cycle and an air-cooled condenser indicates that dry air cooling can be utilized with both cycles provided that the cycle conditions are selected appropriately

  16. Combined Brayton-JT cycles with refrigerants for natural gas liquefaction

    Science.gov (United States)

    Chang, Ho-Myung; Park, Jae Hoon; Lee, Sanggyu; Choe, Kun Hyung

    2012-06-01

    Thermodynamic cycles for natural gas liquefaction with single-component refrigerants are investigated under a governmental project in Korea, aiming at new processes to meet the requirements on high efficiency, large capacity, and simple equipment. Based upon the optimization theory recently published by the present authors, it is proposed to replace the methane-JT cycle in conventional cascade process with a nitrogen-Brayton cycle. A variety of systems to combine nitrogen-Brayton, ethane-JT and propane-JT cycles are simulated with Aspen HYSYS and quantitatively compared in terms of thermodynamic efficiency, flow rate of refrigerants, and estimated size of heat exchangers. A specific Brayton-JT cycle is suggested with detailed thermodynamic data for further process development. The suggested cycle is expected to be more efficient and simpler than the existing cascade process, while still taking advantage of easy and robust operation with single-component refrigerants.

  17. Thermodynamic design of 10 kW Brayton cryocooler for HTS cable

    Science.gov (United States)

    Chang, Ho-Myung; Park, C. W.; Yang, H. S.; Sohn, Song Ho; Lim, Ji Hyun; Oh, S. R.; Hwang, Si Dole

    2012-06-01

    Thermodynamic design of Brayton cryocooler is presented as part of an ongoing governmental project in Korea, aiming at 1 km HTS power cable in the transmission grid. The refrigeration requirement is 10 kW for continuously sub-cooling liquid nitrogen from 72 K to 65 K. An ideal Brayton cycle for this application is first investigated to examine the fundamental features. Then a practical cycle for a Brayton cryocooler is designed, taking into account the performance of compressor, expander, and heat exchangers. Commercial software (Aspen HYSYS) is used for simulating the refrigeration cycle with real fluid properties of refrigerant. Helium is selected as a refrigerant, as it is superior to neon in thermodynamic efficiency. The operating pressure and flow rate of refrigerant are decided with a constraint to avoid the freezing of liquid nitrogen

  18. Cost and price estimate of Brayton and Stirling engines in selected production volumes

    Science.gov (United States)

    Fortgang, H. R.; Mayers, H. F.

    1980-01-01

    The methods used to determine the production costs and required selling price of Brayton and Stirling engines modified for use in solar power conversion units are presented. Each engine part, component and assembly was examined and evaluated to determine the costs of its material and the method of manufacture based on specific annual production volumes. Cost estimates are presented for both the Stirling and Brayton engines in annual production volumes of 1,000, 25,000, 100,000 and 400,000. At annual production volumes above 50,000 units, the costs of both engines are similar, although the Stirling engine costs are somewhat lower. It is concluded that modifications to both the Brayton and Stirling engine designs could reduce the estimated costs.

  19. Revenue sources for financing transportation safety activities in Virginia : phase three, feasibility of a surcharge on traffic fines.

    Science.gov (United States)

    1981-01-01

    Senate Bill 85, an action of the 1978 General Assembly, amended the Code of Virginia to provide, in part, that the Division of Highway Safety be succeeded by the newly created Department of Transportation Safety effective July 1, 1978. In its Declara...

  20. The feasibility and safety of thoracoscopic surgery under epidural and/or local anesthesia for spontaneous pneumothorax: a meta-analysis.

    Science.gov (United States)

    Chen, Wei; Zhang, Chenlei; Wang, Gebang; Li, Zhengjun; Wang, Hailong; Liu, Hongxu

    2017-09-01

    The aim of this study was to compare thoracoscopic surgery for spontaneous pneumothorax under epidural and/or local anesthesia (ELA) with that under general anesthesia and prove the feasibility and safety of thoracoscopic surgery under ELA for spontaneous pneumothorax. Relevant studies were searched in five databases from their date of publication to June 2016. We collected and analyzed the data concerning operative time, hospital stay, complications, air leak, recurrence and perioperative mortality. A forest plot was performed to compare the differences between the two groups. There were no significant differences between the ELA group and the general anesthesia (GA) group in operative time, hospital stay, complications, air leak or recurrence. There were 6 deaths reported in two studies. However, patients in the ELA group had significantly shorter global operating room time. Our study demonstrated that ELA, in comparison with GA, is feasible and safe for thoracoscopic surgery of spontaneous pneumothorax.

  1. Cardiopulmonary Exercise Testing in Patients with Asymptomatic or Equivocal Symptomatic Aortic Stenosis: Feasibility, Reproducibility, Safety and Information Obtained on Exercise Physiology.

    Science.gov (United States)

    van Le, Douet; Jensen, Gunnar Vagn Hagemann; Carstensen, Steen; Kjøller-Hansen, Lars

    2016-01-01

    The aim of this study was to determine the feasibility, reproducibility, safety and information obtained on exercise physiology from cardiopulmonary exercise testing (CPX) in patients with aortic stenosis. Patients with an aortic valve area (AVA) exercise, lower peak heart rate and FEV1, and higher VE/VCO2, but not by AVA index. Equivocal symptomatic status and a low gradient but high valvulo-arterial impedance were associated with a lower pVO2, but not with an inability to increase stroke volume. In total, 18 patients were referred for valve replacement. At 1 year, no cardiovascular deaths had occurred. CPX was feasible and reproducible and provided comprehensive data on exercise physiology. A CPX-guided treatment strategy was safe up to 1 year. © 2015 S. Karger AG, Basel.

  2. Comparison of Direct and Indirect Gas Reactor Brayton Systems for Nuclear Electric Space Propulsion

    International Nuclear Information System (INIS)

    M Postlehwait; P DiLorenzo; S Belanger; J Ashcroft

    2005-01-01

    Gas reactor systems are being considered as candidates for use in generating power for the Prometheus-1 spacecraft, along with other NASA missions as part of the Prometheus program. Gas reactors offer a benign coolant, which increases core and structural materials options. However, the gas coolant has inferior thermal transport properties, relative to other coolant candidates such as liquid metals. This leads to concerns for providing effective heat transfer and for minimizing pressure drop within the reactor core. In direct gas Brayton systems, i.e. those with one or more Brayton turbines in the reactor cooling loop, the ability to provide effective core cooling and low pressure drop is further constrained by the need for a low pressure, high molecular weight gas, typically a mixture of helium and xenon. Use of separate primary and secondary gas loops, one for the reactor and one or more for the Brayton system(s) separated by heat exchanger(s), allows for independent optimization of the pressure and gas composition of each loop. The reactor loop can use higher pressure pure helium, which provides improved heat transfer and heat transport properties, while the Brayton loop can utilize lower pressure He-Xe. However, this approach requires a separate primary gas circulator and also requires gas to gas heat exchangers. This paper focuses on the trade-offs between the direct gas reactor Brayton system and the indirect gas Brayton system. It discusses heat exchanger arrangement and materials options and projects heat exchanger mass based on heat transfer area and structural design needs. Analysis indicates that these heat exchangers add considerable mass, but result in reactor cooling and system resiliency improvements

  3. Safety and feasibility of transcranial direct current stimulation (tDCS) combined with sensorimotor retraining in chronic low back pain: a protocol for a pilot randomised controlled trial.

    Science.gov (United States)

    Ouellette, Adam Louis; Liston, Matthew B; Chang, Wei-Ju; Walton, David M; Wand, Benedict Martin; Schabrun, Siobhan M

    2017-08-21

    Chronic low back pain (LBP) is a common and costly health problem yet current treatments demonstrate at best, small effects. The concurrent application of treatments with synergistic clinical and mechanistic effects may improve outcomes in chronic LBP. This pilot trial aims to (1) determine the feasibility, safety and perceived patient response to a combined transcranial direct current stimulation (tDCS) and sensorimotor retraining intervention in chronic LBP and (2) provide data to support a sample size calculation for a fully powered trial should trends of effectiveness be present. A pilot randomised, assessor and participant-blind, sham-controlled trial will be conducted. Eighty participants with chronic LBP will be randomly allocated to receive either (1) active tDCS + sensorimotor retraining or (2) sham tDCS + sensorimotor retraining. tDCS (active or sham) will be applied to the primary motor cortex for 20 min immediately prior to 60 min of supervised sensorimotor retraining twice per week for 10 weeks. Participants in both groups will complete home exercises three times per week. Feasibility, safety, pain, disability and pain system function will be assessed immediately before and after the 10-week intervention. Analysis of feasibility and safety will be performed using descriptive statistics. Statistical analyses will be conducted based on intention-to-treat and per protocol and will be used to determine trends for effectiveness. Ethical approval has been gained from the institutional human research ethics committee (H10184). Written informed consent will be provided by all participants. Results from this pilot study will be submitted for publication in peer-reviewed journals. ACTRN12616000624482. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. TryCYCLE: A Prospective Study of the Safety and Feasibility of Early In-Bed Cycling in Mechanically Ventilated Patients.

    Directory of Open Access Journals (Sweden)

    Michelle E Kho

    Full Text Available The objective of this study was to assess the safety and feasibility of in-bed cycling started within the first 4 days of mechanical ventilation (MV to inform a future randomized clinical trial.We conducted a 33-patient prospective cohort study in a 21-bed adult academic medical-surgical intensive care unit (ICU in Hamilton, ON, Canada. We included adult patients (≥ 18 years receiving MV who walked independently pre-ICU. Our intervention was 30 minutes of in-bed supine cycling 6 days/week in the ICU. Our primary outcome was Safety (termination, measured as events prompting cycling termination; secondary Safety (disconnection or dislodgement outcomes included catheter/tube dislodgements. Feasibility was measured as consent rate and fidelity to intervention. For our primary outcome, we calculated the binary proportion and 95% confidence interval (CI.From 10/2013-8/2014, we obtained consent from 34 of 37 patients approached (91.9%, 33 of whom received in-bed cycling. Of those who cycled, 16(48.4% were female, the mean (SD age was 65.8(12.2 years, and APACHE II score was 24.3(6.7; 29(87.9% had medical admitting diagnoses. Cycling termination was infrequent (2.0%, 95% CI: 0.8%-4.9% and no device dislodgements occurred. Cycling began a median [IQR] of 3 [2, 4] days after ICU admission; patients received 5 [3, 8] cycling sessions with a median duration of 30.7 [21.6, 30.8] minutes per session. During 205 total cycling sessions, patients were receiving invasive MV (150 [73.1%], vasopressors (6 [2.9%], sedative or analgesic infusions (77 [37.6%] and dialysis (4 [2.0%].Early cycling within the first 4 days of MV among hemodynamically stable patients is safe and feasible. Research to evaluate the effect of early cycling on patient function is warranted.Clinicaltrials.gov: NCT01885442.

  5. Feasibility of a Video-Based Advance Care Planning Website to Facilitate Group Visits among Diverse Adults from a Safety-Net Health System.

    Science.gov (United States)

    Zapata, Carly; Lum, Hillary D; Wistar, Emily; Horton, Claire; Sudore, Rebecca L

    2018-02-20

    Primary care providers in safety-net settings often do not have time to discuss advance care planning (ACP). Group visits (GV) may be an efficient means to provide ACP education. To assess the feasibility and impact of a video-based website to facilitate GVs to engage diverse adults in ACP. Feasibility pilot among patients who were ≥55 years of age from two primary care clinics in a Northern California safety-net setting. Participants attended two 90-minute GVs and viewed the five steps of the movie version of the PREPARE website ( www.prepareforyourcare.org ) concerning surrogates, values, and discussing wishes in video format. Two clinician facilitators were available to encourage participation. We assessed pre-to-post ACP knowledge, whether participants designated a surrogate or completed an advance directive (AD), and acceptability of GVs and PREPARE materials. We conducted two GVs with 22 participants. Mean age was 64 years (±7), 55% were women, 73% nonwhite, and 55% had limited literacy. Knowledge improved about surrogate designation (46% correct pre vs. 85% post, p = 0.01) and discussing decisions with others (59% vs. 90%, p = 0.01). Surrogate designation increased (48% vs. 85%, p = 0.01) and there was a trend toward AD completion (9% vs. 24%, p = 0.21). Participants rated the GVs and PREPARE materials a mean of 8 (±3.1) on a 10-point acceptability scale. Using the PREPARE movie to facilitate ACP GVs for diverse adults in safety net, primary care settings is feasible and shows potential for increasing ACP engagement.

  6. Feasibility study and uncertainties in the validation of an existing safety-related control circuit with the ISO 13849-1:2006 design standard

    International Nuclear Information System (INIS)

    Jocelyn, Sabrina; Baudoin, James; Chinniah, Yuvin; Charpentier, Philippe

    2014-01-01

    In industry, machine users and people who modify or integrate equipment often have to evaluate the safety level of a safety-related control circuit that they have not necessarily designed. The modifications or integrations may involve work to make an existing machine that does not comply with normative or regulatory specifications safe. However, how can a circuit performing a safety function be validated a posteriori? Is the validation exercise feasible? What are the difficulties and limitations of such a procedure? The aim of this article is to answer these questions by presenting a validation study of a safety function of an existing machine. A plastic injection molding machine is used for this study, as well as standard ISO 13849-1:2006. Validation consists of performing an a posteriori (post-design) estimation of the performance level of the safety function. The procedure is studied for two contexts of use of the machine: in industry, and in laboratory. The calculations required by the ISO standard were done using Excel, followed by SIStema software. It is shown that, based on the context of use, the estimated performance level was different for the same safety-related circuit. The variability in the results is explained by the assumptions made by the person undertaking the validation without the involvement of the machine designer. - Highlights: • Validation of the performance level of a safety function is undertaken. • An injection molding machine and ISO 13849-1:2006 standard are used for the procedure. • The procedure is undertaken for two contexts of use of the machine. • In this study, the performance level depends on the context of use. • The assumptions made throughout the study partially explain this difference

  7. Concept definition study of small Brayton cycle engines for dispersed solar electric power systems

    Science.gov (United States)

    Six, L. D.; Ashe, T. L.; Dobler, F. X.; Elkins, R. T.

    1980-01-01

    Three first-generation Brayton cycle engine types were studied for solar application: a near-term open cycle (configuration A), a near-term closed cycle (configuration B), and a longer-term open cycle (configuration C). A parametric performance analysis was carried out to select engine designs for the three configurations. The interface requirements for the Brayton cycle engine/generator and solar receivers were determined. A technology assessment was then carried out to define production costs, durability, and growth potential for the selected engine types.

  8. Task Order 20: Supercritical Carbon Dioxide Brayton Cycle Energy Conversion Study

    Energy Technology Data Exchange (ETDEWEB)

    Murray, Paul [AREVA Federal Services, LLC, Charlotte, NC (United States); Lindsay, Edward [AREVA Federal Services, LLC, Charlotte, NC (United States); McDowell, Michael [AREVA Federal Services, LLC, Charlotte, NC (United States); Huang, Megan [AREVA Federal Services, LLC, Charlotte, NC (United States)

    2015-04-23

    AREVA Inc. developed this study for the US Department of Energy (DOE) office of Nuclear Energy (NE) in accordance with Task Order 20 Statement of Work (SOW) covering research and development activities for the Supercritical Carbon Dioxide (sCO2) Brayton Cycle energy conversion. The study addresses the conversion of sCO2 heat energy to electrical output by use of a Brayton Cycle system and focuses on the potential of a net efficiency increase via cycle recuperation and recompression stages. The study also addresses issues and study needed to advance development and implementation of a 10 MWe sCO2 demonstration project.

  9. Brayton Power Conversion Unit Tested: Provides a Path to Future High-Power Electric Propulsion Missions

    Science.gov (United States)

    Mason, Lee S.

    2003-01-01

    Closed-Brayton-cycle conversion technology has been identified as an excellent candidate for nuclear electric propulsion (NEP) power conversion systems. Advantages include high efficiency, long life, and high power density for power levels from about 10 kWe to 1 MWe, and beyond. An additional benefit for Brayton is the potential for the alternator to deliver very high voltage as required by the electric thrusters, minimizing the mass and power losses associated with the power management and distribution (PMAD). To accelerate Brayton technology development for NEP, the NASA Glenn Research Center is developing a low-power NEP power systems testbed that utilizes an existing 2- kWe Brayton power conversion unit (PCU) from previous solar dynamic technology efforts. The PCU includes a turboalternator, a recuperator, and a gas cooler connected by gas ducts. The rotating assembly is supported by gas foil bearings and consists of a turbine, a compressor, a thrust rotor, and an alternator on a single shaft. The alternator produces alternating-current power that is rectified to 120-V direct-current power by the PMAD unit. The NEP power systems testbed will be utilized to conduct future investigations of operational control methods, high-voltage PMAD, electric thruster interactions, and advanced heat rejection techniques. The PCU was tested in Glenn s Vacuum Facility 6. The Brayton PCU was modified from its original solar dynamic configuration by the removal of the heat receiver and retrofitting of the electrical resistance gas heater to simulate the thermal input of a steady-state nuclear source. Then, the Brayton PCU was installed in the 3-m test port of Vacuum Facility 6, as shown. A series of tests were performed between June and August of 2002 that resulted in a total PCU operational time of about 24 hr. An initial test sequence on June 17 determined that the reconfigured unit was fully operational. Ensuing tests provided the operational data needed to characterize PCU

  10. Safety

    International Nuclear Information System (INIS)

    1998-01-01

    A brief account of activities carried out by the Nuclear power plants Jaslovske Bohunice in 1997 is presented. These activities are reported under the headings: (1) Nuclear safety; (2) Industrial and health safety; (3) Radiation safety; and Fire protection

  11. First-in-Human Ultrasound Molecular Imaging With a VEGFR2-Specific Ultrasound Molecular Contrast Agent (BR55) in Prostate Cancer: A Safety and Feasibility Pilot Study.

    Science.gov (United States)

    Smeenge, Martijn; Tranquart, François; Mannaerts, Christophe K; de Reijke, Theo M; van de Vijver, Marc J; Laguna, M Pilar; Pochon, Sibylle; de la Rosette, Jean J M C H; Wijkstra, Hessel

    2017-07-01

    BR55, a vascular endothelial growth factor receptor 2 (VEGFR2)-specific ultrasound molecular contrast agent (MCA), has shown promising results in multiple preclinical models regarding cancer imaging. In this first-in-human, phase 0, exploratory study, we investigated the feasibility and safety of the MCA for the detection of prostate cancer (PCa) in men using clinical standard technology. Imaging with the MCA was performed in 24 patients with biopsy-proven PCa scheduled for radical prostatectomy using a clinical ultrasound scanner at low acoustic power. Safety monitoring was done by physical examination, blood pressure and heart rate measurements, electrocardiogram, and blood sampling. As first-in-human study, MCA dosing and imaging protocol were necessarily fine-tuned along the enrollment to improve visualization. Imaging data were correlated with radical prostatectomy histopathology to analyze the detection rate of ultrasound molecular imaging with the MCA. Imaging with MCA doses of 0.03 and 0.05 mL/kg was adequate to obtain contrast enhancement images up to 30 minutes after administration. No serious adverse events or clinically meaningful changes in safety monitoring data were identified during or after administration. BR55 dosing and imaging were fine-tuned in the first 12 patients leading to 12 subsequent patients with an improved MCA dosing and imaging protocol. Twenty-three patients underwent radical prostatectomy. A total of 52 lesions were determined to be malignant by histopathology with 26 (50%) of them seen during BR55 imaging. In the 11 patients that were scanned with the improved protocol and underwent radical prostatectomy, a total of 28 malignant lesions were determined: 19 (68%) were seen during BR55 ultrasound molecular imaging, whereas 9 (32%) were not identified. Ultrasound molecular imaging with BR55 is feasible with clinical standard technology and demonstrated a good safety profile. Detectable levels of the MCA can be reached in patients

  12. Feasibility of Exploiting Celution^ System in Autologous Cell Therapy in Dokkyo Medical University Hospital:Safety and Reproducibility

    OpenAIRE

    Ken-ichi, Inoue; Hiroshi, Nomura; Ryoichi, Sohma; Kazumi, Akimoto; Naohiko, Kobayashi; Takao, Kamai; Tomonori, Yamanishi; Isao, Taguchi; Hiroki, Asato; Teruo, Inoue; Tomoyuki, Mitsumori; Hideki, Iwaguro; Ken-ichiro, Yoshida; Research Support Center, Dokkyo Medical University School Of Medicine:Center For Regenerative Medicine, Dokkyo Medical University School Of Medicine; Center For Regenerative Medicine, Dokkyo Medical University School Of Medicine:Department Of Plastic And Reconstructive Surgery, Dokkyo Medical University School Of Medicine

    2014-01-01

    In 2012, we established the Center for Regenerative Medicine in Dokkyo Medical University Hospital, and are now preparing the necessary equipment and preclinical evidence for cell therapy. Liposuction is a commonly used procedure in plastic surgery and the lipoaspirate is discarded as a medical waste. However, the lipoaspirate is known to contain abundant mesenchymal stem cells, and thus, it is currently one of the most feasible options of regenerative medicine. Several ongoing clinical trial...

  13. Cooking Healthy, Eating Smart (CHES): Evaluating the feasibility of using volunteers to deliver nutrition and food safety education to rural older adults

    Science.gov (United States)

    Getty, Morgan

    Due to their limited resources, rural, older adults in the United States are at risk for poor diet-related health outcomes. Nutrition education is a key component in improving health outcomes in older adults. Cooking Healthy, Eating Smart (CHES) is a nine-lesson curriculum designed to teach rural, older adults culturally appropriate nutrition and food safety information. Funding to hire health professionals to deliver such a curriculum is limited, presenting the need to explore a less expensive mode of dissemination. In this community-based, participatory research study, a formative evaluation and feasibility study were conducted to examine the use of volunteers to deliver a nutrition and food safety curriculum to rural, older adults in South Carolina. Seven focus groups were conducted with members of the South Carolina Family and Community Leaders (SCFCL) and members of the American Association of Retired Persons (AARP) in the four regions of South Carolina to explore barriers and facilitators of volunteers delivering CHES (N=65 participants). The focus group findings informed the development of the volunteer training manual. A comparative case study method was used to examine the feasibility of a volunteer-based approach by observing and describing the delivery of CHES by two groups of volunteers in SC. The case study findings, including volunteer knowledge change, self-efficacy change, curriculum experience, program experience, and project team observations of volunteers indicated that using volunteers to deliver CHES is a plausible approach with the assistance of paid staff or project team members.

  14. Safety and feasibility of transcranial direct current stimulation in amyotrophic lateral sclerosis - a pilot study with a single subject experimental design.

    Science.gov (United States)

    Madhavan, Sangeetha; Sivaramakrishnan, Anjali; Bond, Sam; Jiang, Qin Li

    2018-02-28

    Transcranial direct current stimulation (tDCS) has been explored as a neuromodulatory tool to prime motor function in several neurological disorders. Studies using tDCS in amyotrophic lateral sclerosis (ALS) are limited. We investigated the safety, feasibility and effects of long-term tDCS in an individual with ALS. A 36-year-old male diagnosed with clinically definite ALS received 12 sessions each of anodal, sham, and cathodal tDCS. Outcome measures included disease progression (revised ALS functional rating scale (ALSFRS-R)), clinical measures of endurance and mobility, and corticomotor excitability. No adverse events or change in disease progression were noticed during the study. Small improvement in gait speed (15% increase) was noticed with anodal tDCS only. This case study demonstrates the safety and feasibility of long-term facilitatory and inhibitory tDCS on a single participant with ALS. This study serves as a guideline for implementing tDCS in future ALS trials.

  15. The use of in-situ simulation to improve safety in the plastic surgery office: a feasibility study.

    Science.gov (United States)

    Shapiro, Fred E; Pawlowski, John B; Rosenberg, Noah M; Liu, Xiaoxia; Feinstein, David M; Urman, Richard D

    2014-01-01

    Simulation-based interventions and education can potentially contribute to safer and more effective systems of care. We utilized in-situ simulation to highlight safety issues, regulatory requirements, and assess perceptions of safety processes by the plastic surgery office staff. A high-fidelity human patient simulator was brought to an office-based plastic surgery setting to enact a half-day full-scale, multidisciplinary medical emergency. Facilitated group debriefings were conducted after each scenario with special consideration of the principles of team training, communication, crisis management, and adherence to evidence-based protocols and regulatory standards. Abbreviated AHRQ Medical Office Safety Culture Survey was completed by the participants before and after the session. The in-situ simulations had a high degree of acceptance and face validity according to the participants. Areas highlighted by the simulation sessions included rapid communication, delegation of tasks, location of emergency materials, scope of practice, and logistics of transport. The participant survey indicated greater awareness of patient safety issues following participation in simulation and debriefing exercises in 3 areas (P issue (100% vs 75%), openness to ideas about improving office processes (100% vs 88%), and the need to discuss ways to prevent errors from recurring (88% vs 62%). Issues of safety and regulatory compliance can be assessed in an office-based setting through the short-term (half-day) use of in-situ simulation with facilitated debriefing and the review of audiovisual recordings by trained facilities inspectors.

  16. "FIND Technology": investigating the feasibility, efficacy and safety of controller-free interactive digital rehabilitation technology in an inpatient stroke population: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Bird, M L; Cannell, J; Callisaya, M L; Moles, E; Rathjen, A; Lane, K; Tyson, A; Smith, S

    2016-04-16

    Stroke results in significant disability, which can be reduced by physical rehabilitation. High levels of repetition and activity are required in rehabilitation, but patients are typically sedentary. Using clinically relevant and fun computer games may be one way to achieve increased activity in rehabilitation. A single-blind randomized controlled trial will be conducted to evaluate the feasibility, efficacy and safety of novel stroke-specific rehabilitation software. This software uses controller-free client interaction and inertial motion sensors. Elements of feasibility include recruitment into the trial, ongoing participation (adherence and dropout), perceived benefit, enjoyment and ease of use of the games. Efficacy will be determined by measuring activity and using upper-limb tasks as well as measures of balance and mobility. The hypothesis that the intervention group will have increased levels of physical activity within rehabilitation and improved physical outcomes compared with the control group will be tested. Results from this study will provide a basis for discussion of feasibility of this interactive video technological solution in an inpatient situation. Differences in activity levels between groups will be the primary measure of efficacy. It will also provide data on measures of upper-limb function, balance and mobility. ACTRN12614000427673 . Prospectively registered 17 April 2014.

  17. Applicability and feasibility of systematic review for performing evidence-based risk assessment in food and feed safety

    DEFF Research Database (Denmark)

    Aiassa, E.; Higgins, J.P.T.; Frampton, G. K.

    2015-01-01

    for answering questions in health care, and can be implemented to minimise biases in food and feed safety risk assessment. However, no methodological frameworks exist for refining risk assessment multi-parameter models into questions suitable for systematic review, and use of meta-analysis to estimate all......Food and feed safety risk assessment uses multi-parameter models to evaluate the likelihood of adverse events associated with exposure to hazards in human health, plant health, animal health, animal welfare and the environment. Systematic review and meta-analysis are established methods...... parameters in the risk model. This approach to planning and prioritising systematic review seems to have useful implications for producing evidence-based food and feed safety risk assessment....

  18. Safety and Feasibility of a Ketamine Package to Support Emergency and Essential Surgery in Kenya when No Anesthetist is Available: An Analysis of 1216 Consecutive Operative Procedures.

    Science.gov (United States)

    Burke, Thomas F; Suarez, Sebastian; Sessler, Daniel I; Senay, Ayla; Yusufali, Taha; Masaki, Charles; Guha, Moytrayee; Rogo, Debora; Jani, Pankaj; Nelson, Brett D; Rogo, Khama

    2017-12-01

    Lack of access to emergency and essential surgery is widespread in low- and middle-income countries. Scarce anesthesia services contribute to this unmet need. The aim of this study was to evaluate the safety and feasibility of the Every Second Matters for Emergency and Essential Surgery-Ketamine (ESM-Ketamine) package for emergency and essential procedures when no anesthetist was available. From November 2013 to September 2017, the ESM-Ketamine package was used for patients requiring emergency or life-improving surgeries in fifteen selected facilities across Kenya when no anesthetist was available. A mixed-methods approach was used to assess safety and feasibility of the ESM-Ketamine package, including demand, acceptability, and practicality. The primary outcome was ketamine-related adverse events. Key-informant interviews captured perceptions of providers, hospital administrators, and surgeons/proceduralists. Non-anesthetist mid-level providers used ESM-Ketamine for 1216 surgical procedures across the fifteen study facilities. The median ketamine dose was 2.1 mg/kg. Brief (30 s) oxygen desaturations occurred in seven patients (0.6%). There were 157 (13%) reported cases of hallucinations and agitation which were treated with diazepam. All patients recovered uneventfully, and no ketamine-related deaths were reported. Twenty-seven key-informant interviews showed strong support for the program with four main themes: financial considerations, provision of services, staff impact, and scaling considerations. The ESM-Ketamine package appears safe and feasible and is capable of expanding access to emergency and essential surgeries in rural Kenya when no anesthetist is available.

  19. Examining the safety of menstrual cups among rural primary school girls in western Kenya: observational studies nested in a randomised controlled feasibility study.

    Science.gov (United States)

    Juma, Jane; Nyothach, Elizabeth; Laserson, Kayla F; Oduor, Clifford; Arita, Lilian; Ouma, Caroline; Oruko, Kelvin; Omoto, Jackton; Mason, Linda; Alexander, Kelly T; Fields, Barry; Onyango, Clayton; Phillips-Howard, Penelope A

    2017-05-04

    Examine the safety of menstrual cups against sanitary pads and usual practice in Kenyan schoolgirls. Observational studies nested in a cluster randomised controlled feasibility study. 30 primary schools in a health and demographic surveillance system in rural western Kenya. Menstruating primary schoolgirls aged 14-16 years participating in a menstrual feasibility study. Insertable menstrual cup, monthly sanitary pads or 'usual practice' (controls). Staphylococcus aureus vaginal colonization, Escherichia coli growth on sampled used cups, toxic shock syndrome or other adverse health outcomes. Among 604 eligible girls tested, no adverse event or TSS was detected over a median 10.9 months follow-up. S. aureus prevalence was 10.8%, with no significant difference over intervention time or between groups. Of 65  S.aureus positives at first test, 49 girls were retested and 10 (20.4%) remained positive. Of these, two (20%) sample isolates tested positive for toxic shock syndrome toxin-1; both girls were provided pads and were clinically healthy. Seven per cent of cups required replacements for loss, damage, dropping in a latrine or a poor fit. Of 30 used cups processed for E. coli growth, 13 (37.1%, 95% CI 21.1% to 53.1%) had growth. E. coli growth was greatest in newer compared with established users (53%vs22.2%, p=0.12). Among this feasibility sample, no evidence emerged to indicate menstrual cups are hazardous or cause health harms among rural Kenyan schoolgirls, but large-scale trials and post-marketing surveillance should continue to evaluate cup safety. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Performance evaluation and parametric choice criteria of a Brayton pumped thermal electricity storage system

    International Nuclear Information System (INIS)

    Guo, Juncheng; Cai, Ling; Chen, Jincan; Zhou, Yinghui

    2016-01-01

    A more realistic thermodynamic model of the pumped thermal electricity storage (PTES) system consisting of a Brayton cycle and a reverse Brayton cycle is proposed, where the internal and external irreversible losses are took into account and several important controlling parameters, e.g., the pressure ratio and heat flows of the two isobaric processes in the Brayton cycle, are introduced. Analytic expressions for the round trip efficiency and power output of the PTES system are derived. The general performance characteristics of the PTES system are revealed. The optimal relationship between the round trip efficiency and the power output is obtained. The influences of some important controlling parameters on the performance characteristics of the PTES system are discussed and the optimally operating regions of these parameters are determined. - Highlights: • A cycle model of the Brayton pumped thermal electricity storage system is proposed. • Internal and external irreversible losses are considered. • Maximum power output and efficiency of the system are calculated. • Optimum performance characteristics of the system are revealed. • Rational ranges of key controlling parameters are determined.

  1. Optimization of a regenerative Brayton cycle by maximization of a newly defined second law efficiency

    NARCIS (Netherlands)

    Haseli, Y.

    2013-01-01

    The idea is to find out whether 2nd law efficiency optimization may be a suitable trade-off between maximum work output and maximum 1st law efficiency designs for a regenerative gas turbine engine operating on the basis of an open Brayton cycle. The primary emphasis is placed on analyzing the ideal

  2. Computational analysis of supercritical CO2 Brayton cycle power conversion system for fusion reactor

    International Nuclear Information System (INIS)

    Halimi, Burhanuddin; Suh, Kune Y.

    2012-01-01

    Highlights: ► Computational analysis of S-CO 2 Brayton cycle power conversion system. ► Validation of numerical model with literature data. ► Recompression S-CO 2 Brayton cycle thermal efficiency of 42.44%. ► Reheating concept to enhance the cycle thermal efficiency. ► Higher efficiency achieved by the proposed concept. - Abstract: The Optimized Supercritical Cycle Analysis (OSCA) code is being developed to analyze the design of a supercritical carbon dioxide (S-CO 2 ) driven Brayton cycle for a fusion reactor as part of the Modular Optimal Balance Integral System (MOBIS). This system is based on a recompression Brayton cycle. S-CO 2 is adopted as the working fluid for MOBIS because of its easy availability, high density and low chemical reactivity. The reheating concept is introduced to enhance the cycle thermal efficiency. The helium-cooled lithium lead model AB of DEMO fusion reactor is used as reference in this paper.

  3. Identified corrosion and erosion mechanisms in SCO2 Brayton Cycles.

    Energy Technology Data Exchange (ETDEWEB)

    Fleming, Darryn D.; Kruizenga, Alan Michael

    2014-06-01

    Supercritical Carbon Dioxide (S-CO2) is an efficient and flexible working fluid for power production. Research to interface S-CO2 systems with nuclear, thermal solar, and fossil energy sources is currently underway. To proceed, we must address concerns regarding compatibility of materials, at high temperature, and compatibility between significantly different heat transfer fluids. Dry, pure S-CO2 is thought to be relatively inert [1], while the addition of ppm levels of water and oxygen result in formation of a protective chromia layer and iron oxide [2]. Thin oxides are favorable as diffusion barriers, and for their minimal impact on heat transfer. While S-CO2 is typically understood to be the secondary fluid, many varieties of primary fluids exist for nuclear applications. Molten salts, for use in the Molten Salt Reactor concept, are given as an example to contrast the materials requirements of primary and secondary fluids. Thin chromia layers are soluble in molten salt systems (nitrate, chloride, and fluoride based salts) [3-8], making materials selection for heat exchangers a precarious balancing act between high temperature oxidation (S-CO2) and metal dissolution (salt side of heat exchanger). Because concerns have been raised regarding component lifetimes, S-CO2 work has begun to characterize starting materials and to establish a baseline by analysis of 1) as-received stainless steel piping, and 2) piping exposed to S-CO2 under typical operating conditions with Sandia National Laboratories Brayton systems. A second issue discovered by SNL involves substantial erosion in the turbine blade and inlet nozzle. It is believed that this is caused by small particulates that originate from different materials around the loop that are entrained by the S-CO2 to the nozzle, where they impact the inlet nozzle vanes, causing erosion. We believe that, in some way, this is linked to the purity of the S-CO2, the corrosion contaminants, and the metal particulates that

  4. Systematic review and meta-analysis of feasibility, safety, and efficacy of a novel procedure: associating liver partition and portal vein ligation for staged hepatectomy.

    Science.gov (United States)

    Schadde, Erik; Schnitzbauer, Andreas A; Tschuor, Christoph; Raptis, Dimitri A; Bechstein, Wolf O; Clavien, Pierre-Alain

    2015-09-01

    Associating liver partition and portal vein ligation for staged hepatectomy (ALPPS) is a novel strategy to resect liver tumors despite the small size of the liver remnant. It is an hepatectomy in two stages, with PVL and parenchymal transection during the first stage, which induces rapid growth of the remnant liver exceeding any other technique. Despite high postoperative morbidity and mortality in most reports, the technique was adopted by a number of surgeons. This systematic review explores current data regarding the feasibility, safety, and oncologic efficacy of ALPPS; the search strategy has been published online. A meta-analysis of hypertrophy, feasibility (ALPPS stage 2 performed), mortality, complications, and R0 (complete) resection was performed. A literature search revealed a total of 13 publications that met the search criteria, reporting data from 295 patients. Evidence levels were low, with the highest Oxford evidence level being 2c. The most common indication was colorectal liver metastasis in 203 patients. Hypertrophy in the meta-analysis was 84 %, feasibility (ALPPS stage 2 performed) 97 % (CI 94-99 %), 90-day mortality 11 % (CI 8-16 %), and complications grade IIIa or higher occured in 44 % (CI 38-50 %) of patients. A standardized reporting format for complications is lacking despite the widespread use of the Clavien-Dindo classification. Oncological outcome is not well-documented. The most common topics in the selected studies published were technical feasibility and indications for the procedures. Publication bias due to case-series and single-center reports is common. A systematic exploration of this novel operation with a rigid methodology, such as registry analyses and a randomized controlled trial, is highly advised.

  5. Digital computer study of nuclear reactor thermal transients during startup of 60-kWe Brayton power conversion system

    Science.gov (United States)

    Jefferies, K. S.; Tew, R. C.

    1974-01-01

    A digital computer study was made of reactor thermal transients during startup of the Brayton power conversion loop of a 60-kWe reactor Brayton power system. A startup procedure requiring the least Brayton system complication was tried first; this procedure caused violations of design limits on key reactor variables. Several modifications of this procedure were then found which caused no design limit violations. These modifications involved: (1) using a slower rate of increase in gas flow; (2) increasing the initial reactor power level to make the reactor respond faster; and (3) appropriate reactor control drum manipulation during the startup transient.

  6. Feasibility and Safety of a Powered Exoskeleton for Assisted Walking for Persons With Multiple Sclerosis: A Single-Group Preliminary Study.

    Science.gov (United States)

    Kozlowski, Allan J; Fabian, Michelle; Lad, Dipan; Delgado, Andrew D

    2017-07-01

    To examine the feasibility, safety, and secondary benefit potential of exoskeleton-assisted walking with one device for persons with multiple sclerosis (MS). Single-group longitudinal preliminary study with 8-week baseline, 8-week intervention, and 4-week follow-up. Outpatient MS clinic, tertiary care hospital. Participants (N=13; age range, 38-62y) were mostly women with Expanded Disability Status Scale scores ranging from 5.5 to 7.0. Exoskeleton-assisted walk training. Primary outcomes were accessibility (enrollment/screen pass), tolerability (completion/dropout), learnability (time to event for standing, walking, and sitting with little or no assistance), acceptability (satisfaction on the device subscale of the Quebec User Evaluation of Satisfaction with Assistive Technology version 2), and safety (event rates standardized to person-time exposure in the powered exoskeleton). Secondary outcomes were walking without the device (timed 25-foot walk test and 6-minute walk test distance), spasticity (Modified Ashworth Scale), and health-related quality of life (Patient-Reported Outcomes Measurement and Information System pain interference and Quality of Life in Neurological Conditions fatigue, sleep disturbance, depression, and positive affect and well-being). The device was accessible to 11 and tolerated by 5 participants. Learnability was moderate, with 5 to 15 sessions required to walk with minimal assistance. Safety was good; the highest adverse event rate was for skin issues at 151 per 1000 hours' exposure. Acceptability ranged from not very satisfied to very satisfied. Participants who walked routinely improved qualitatively on sitting, standing, or walking posture. Two participants improved and 2 worsened on ≥1 quality of life domain. The pattern of spasticity scores may indicate potential benefit. The device appeared feasible and safe for about a third of our sample, for whom routine exoskeleton-assisted walking may offer secondary benefits. Copyright

  7. Safety and feasibility of STAT RAD: Improvement of a novel rapid tomotherapy-based radiation therapy workflow by failure mode and effects analysis.

    Science.gov (United States)

    Jones, Ryan T; Handsfield, Lydia; Read, Paul W; Wilson, David D; Van Ausdal, Ray; Schlesinger, David J; Siebers, Jeffrey V; Chen, Quan

    2015-01-01

    The clinical challenge of radiation therapy (RT) for painful bone metastases requires clinicians to consider both treatment efficacy and patient prognosis when selecting a radiation therapy regimen. The traditional RT workflow requires several weeks for common palliative RT schedules of 30 Gy in 10 fractions or 20 Gy in 5 fractions. At our institution, we have created a new RT workflow termed "STAT RAD" that allows clinicians to perform computed tomographic (CT) simulation, planning, and highly conformal single fraction treatment delivery within 2 hours. In this study, we evaluate the safety and feasibility of the STAT RAD workflow. A failure mode and effects analysis (FMEA) was performed on the STAT RAD workflow, including development of a process map, identification of potential failure modes, description of the cause and effect, temporal occurrence, and team member involvement in each failure mode, and examination of existing safety controls. A risk probability number (RPN) was calculated for each failure mode. As necessary, workflow adjustments were then made to safeguard failure modes of significant RPN values. After workflow alterations, RPN numbers were again recomputed. A total of 72 potential failure modes were identified in the pre-FMEA STAT RAD workflow, of which 22 met the RPN threshold for clinical significance. Workflow adjustments included the addition of a team member checklist, changing simulation from megavoltage CT to kilovoltage CT, alteration of patient-specific quality assurance testing, and allocating increased time for critical workflow steps. After these modifications, only 1 failure mode maintained RPN significance; patient motion after alignment or during treatment. Performing the FMEA for the STAT RAD workflow before clinical implementation has significantly strengthened the safety and feasibility of STAT RAD. The FMEA proved a valuable evaluation tool, identifying potential problem areas so that we could create a safer workflow

  8. Study protocol for the FITR Heart Study: Feasibility, safety, adherence, and efficacy of high intensity interval training in a hospital-initiated rehabilitation program for coronary heart disease.

    Science.gov (United States)

    Taylor, Jenna; Keating, Shelley E; Leveritt, Michael D; Holland, David J; Gomersall, Sjaan R; Coombes, Jeff S

    2017-12-01

    For decades, moderate intensity continuous training (MICT) has been the cornerstone of exercise prescription for cardiac rehabilitation (CR). High intensity interval training (HIIT) is now recognized in CR exercise guidelines as an appropriate and efficient modality for improving cardiorespiratory fitness, a strong predictor of mortality. However, the clinical application of HIIT in a real world CR setting, in terms of feasibility, safety, and long-term adherence, needs further investigation to address ongoing reservations. Furthermore, studies using objective measures of exercise intensity (such as heart rate; HR) have produced variable outcomes. Therefore we propose investigating the use of subjective measures (such as rating of perceived exertion (RPE)) for prescribing exercise intensity. One hundred adults with coronary artery disease (CAD) attending a hospital-initiated CR program will be randomized to 1) HIIT: 4 × 4 min high intensity intervals at 15-18 RPE interspersed with 3-min active recovery periods or 2) MICT: usual care exercise including 40 min continuous exercise at a moderate intensity corresponding to 11-13 RPE. Primary outcome is change in exercise capacity (peak VO 2 ) following 4 weeks of exercise training. Secondary outcome measures are: feasibility, safety, exercise adherence, body composition, vascular function, inflammatory markers, intrahepatic lipid, energy intake, and dietary behavior over 12-months; and visceral adipose tissue (VAT) following 12 weeks of exercise training. This study aims to address the ongoing concerns regarding the practicality and safety of HIIT in CR programs. We anticipate study findings will lead to the development of a standardized protocol to facilitate CR programs to incorporate HIIT as a standard exercise option for appropriate patients.

  9. Feasibility and safety of early lower limb robot-assisted training in sub-acute stroke patients: a pilot study.

    Science.gov (United States)

    Gandolfi, Marialuisa; Geroin, Christian; Tomelleri, Christopher; Maddalena, Isacco; Kirilova Dimitrova, Eleonora; Picelli, Alessandro; Smania, Nicola; Waldner, Andreas

    2017-12-01

    So far, the development of robotic devices for the early lower limb mobilization in the sub-acute phase after stroke has received limited attention. To explore the feasibility of a newly robotic-stationary gait training in sub-acute stroke patients. To report the training effects on lower limb function and muscle activation. A pilot study. Rehabilitation ward. Two sub-acute stroke inpatients and ten age-matched healthy controls were enrolled. Healthy controls served as normative data. Patients underwent 10 robot-assisted training sessions (20 minutes, 5 days/week) in alternating stepping movements (500 repetitions/session) on a hospital bed in addition to conventional rehabilitation. Feasibility outcome measures were compliance, physiotherapist time, and responses to self-report questionnaires. Efficacy outcomes were bilateral lower limb muscle activation pattern as measured by surface electromyography (sEMG), Motricity Index (MI), Medical Research Council (MRC) grade, and Ashworth Scale (AS) scores before and after training. No adverse events occurred. No significant differences in sEMG activity between patients and healthy controls were observed. Post-training improvement in MI and MRC scores, but no significant changes in AS scores, were recorded. Post-treatment sEMG analysis of muscle activation patterns showed a significant delay in rectus femoris offset (P=0.02) and prolonged duration of biceps femoris (P=0.04) compared to pretreatment. The robot-assisted training with our device was feasible and safe. It induced physiological muscle activations pattern in both stroke patients and healthy controls. Full-scale studies are needed to explore its potential role in post-stroke recovery. This robotic device may enrich early rehabilitation in subacute stroke patients by inducing physiological muscle activation patterns. Future studies are warranted to evaluate its effects on promoting restorative mechanisms involved in lower limb recovery after stroke.

  10. Sensitivity study on nitrogen Brayton cycle coupled with a small ultra-long cycle fast reactor

    International Nuclear Information System (INIS)

    Seo, Seok Bin; Seo, Han; Bang, In Cheol

    2014-01-01

    The main characteristics of UCFR are constant neutron flux and power density. They move their positions every moment at constant speed along with axial position of fuel rod for 60 years. Simultaneously with the development of the reactors, a new power conversion system has been considered. To solve existing issues of vigorous sodium-water reaction in SFR with steam power cycle, many researchers suggested a closed Brayton cycle as an alternative technique for SFR power conversion system. Many inactive gases are selected as a working fluid in Brayton power cycle, mainly supercritical CO 2 (S-CO 2 ). However, S-CO 2 still has potential for reaction with sodium. CO 2 -sodium reaction produces solid product, which has possibility to have an auto ignition reaction around 600 .deg. C. Thus, instead of S-CO 2 , CEA in France has developed nitrogen power cycle for ASTRID (Advanced Sodium Technological Reactor for Industrial Demonstration). In addition to inactive characteristic of nitrogen with sodium, its thermal and physical similarity with air enables to easily adopt to existing air Brayton cycle technology. In this study, for an optimized power conversion system for UCFR, a nitrogen Brayton cycle was analyzed in thermodynamic aspect. Based on subchannel analysis data of UCFR-100, a parametric study for thermal performance of nitrogen Brayton cycle was achieved. The system maximum pressure significantly affects to the overall efficiency of cycle, while other parameters show little effects. Little differences of the overall efficiencies for all cases between three stages (BOC, MOC, EOC) indicate that the power cycle of UCFR-100 maintains its performance during the operation

  11. Diagnostic feasibility and safety of CT-guided core biopsy for lung nodules less than or equal to 8 mm. A single-institution experience

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Ying-Yueh [Taipei Veterans General Hospital, Department of Radiology, Taipei (China); Chen, Chun-Ku [Taipei Veterans General Hospital, Department of Radiology, Taipei (China); National Yang-Ming University, School of Medicine, Taipei (China); National Yang-Ming University, Institute of Clinical Medicine, Taipei (China); Yeh, Yi-Chen [National Yang-Ming University, School of Medicine, Taipei (China); Taipei Veterans General Hospital, Department of Pathology and Laboratory Medicine, Taipei (China); Wu, Mei-Han [Taipei Veterans General Hospital, Department of Radiology, Taipei (China); National Yang-Ming University, School of Medicine, Taipei (China)

    2018-02-15

    This retrospective study evaluated the diagnostic yield and safety of CT-guided core biopsy of pulmonary nodules ≤8 mm. We determined the diagnostic yield and safety profile of CT-guided lung biopsies for 125 pulmonary nodules ≤8 mm. Pathological diagnoses were made by a combination of histopathological examination and imprint cytology. Results were compared with biopsy results for 134 pulmonary nodules >8 and ≤10 mm. Final diagnoses were established in 94 nodules ≤8 mm. The sensitivity, specificity and diagnostic accuracy of CT-guided core biopsy for nodules ≤8 mm were 87.1 % (61/70 nodules), 100 % (24/24) and 90.4 % (85/94), respectively. Diagnostic failure rates were comparable for nodules ≤8 mm and nodules >8 mm and ≤10 mm (9/94, 9.6 % and 7/111, 6.3 %, respectively, P=0.385). The rate of tube thoracostomy for nodules ≤8 mm was comparable to that for nodules >8 and ≤10 mm (1.6 % vs. 0.7 %, P=0.611). Nodules ≤6 mm had a higher non-diagnostic result rate of 15.4 % (6/39) than did nodules >8 and ≤10 mm (3.7 %, 5/134, P=0.017). CT-guided pulmonary biopsy is feasible for lung nodules ≤8 mm, especially those >6 mm, and has an acceptable diagnostic yield and safety profile. (orig.)

  12. Para-aortic lymphadenectomy in advanced stage cervical cancer, a protocol for comparing safety, feasibility and diagnostic accuracy of surgical staging versus PET-CT; PALDISC trial.

    Science.gov (United States)

    Tax, Casper; Abbink, Karin; Rovers, Maroeska M; Bekkers, Ruud L M; Zusterzeel, Petra L M

    2018-01-01

    Currently, a PET-CT is used to assess the need for extended field radiotherapy of para-aortic lymph nodes (PALN) in International Federation of Gynaecology and Obstetrics (FIGO) stage IB2, IIA2-IVA (locally advanced stage) cervical cancer. A small study established a sensitivity and specificity estimate for PALN metastases of 50% (95% CI; 7-93%) and 83% (95% CI; 52-98%), respectively. Surgical staging of PALN may lead to a higher diagnostic accuracy. However, surgical staging of para-aortic lymph nodes in locally advanced stage cervical cancer is not common practice. Therefore, a phase 2 randomised controlled trial is needed to assess its safety and feasibility. In addition to standard imaging (MRI or CT scan) with PET-CT, 30 adult women with FIGO stage IB2, IIA2-IVA cervical cancer will be randomised to receive either surgical staging or usual PET-CT staging. Administering extended field radiotherapy will be based on lymphadenectomy results for the intervention group and on the PET-CT results for the control group. Follow-up visits at 0, 3, 6, 9 and 12 months will assess health-related quality of life and progression-free survival.Primary safety and feasibility outcomes of surgical staging will be assessed by calculating means with 95% confidence intervals for duration of surgery, number of complications, blood loss, nodal yield after para-aortic lymphadenectomy and treatment delay due to surgical staging. Secondary patient-centred outcomes on quality of life and first year survival will be documented and compared between the two groups. Estimates of sensitivity, specificity and negative and positive predictive values of MRI, PET-CT and surgical staging will be presented with 95% CI.. All analysis will be performed according to the intention to treat principle. This study will assess safety and feasibility, expressed as the number and severity of complications, effect on quality of life and the treatment delay due to surgically staging para-aortic lymph nodes in

  13. Self-expandable stent loaded with {sup 125}I seeds: Feasibility and safety in a rabbit model

    Energy Technology Data Exchange (ETDEWEB)

    Guo Jinhe [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); Teng Gaojun [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China)]. E-mail: gjteng@vip.sina.com; Zhu Guangyu [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); He Shicheng [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); Deng Gang [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); He Jie [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China)

    2007-02-15

    Objective: To evaluate technical feasibility and acute and subacute radiotolerance of a self-expandable stent loaded with {sup 125}I seeds in the rabbit esophagus. Methods: A self-expandable stent designed for esophageal application was made of 0.16 mm nitinol wire and loaded with {sup 125}I seeds (CIAE-6711). Twenty-seven stents with three different radioactive dosages (n = 9 in each dosage group) were implanted in the esophagus of healthy rabbits, while nine stents alone were used as controls. The stents were perorally deployed into the esophagus under fluoroscopic guidance. Radiological follow-up included plain chest film, CT scan, and barium esophagography which were undertaken in all rabbits of each group at 2, 4, and 8 weeks, respectively, which were correlated to histopathological findings. The stented esophageal segments along with their adjacent tissues were harvested for histopathological examinations. Results: The stent was successfully deployed into the targeted esophageal segment in all rabbits. Neither {sup 125}I seeds dislodged from the stent during the deployment, nor they did during the follow-up period. The greatest (16.2 Gy) absorbed dose was found in the tissue 10 mm from {sup 125}I seeds at 8 weeks. Slight epithelial hyperplasia on the stent surface and submucosal inflammatory process developed at 2 weeks, which reached the peak at 8 weeks after the procedure. Significant thickness of the esophageal muscular layer was found at 8 weeks only in the groups with {sup 125}I seeds. On radiologic follow-up, moderate strictures on both ends of the stents developed at 4 weeks and became severe at 8 weeks after the procedure in all groups. Conclusion: Deployment of a self-expandable stent loaded with {sup 125}I seeds is technically feasible and safe within the first 8 weeks. Acute and subacute radiotolerance of the treated esophagus and its adjacent tissues by {sup 125}I seeds is well preserved in a healthy rabbit model.

  14. Parametric Investigation and Thermoeconomic Optimization of a Combined Cycle for Recovering the Waste Heat from Nuclear Closed Brayton Cycle

    Directory of Open Access Journals (Sweden)

    Lihuang Luo

    2016-01-01

    Full Text Available A combined cycle that combines AWM cycle with a nuclear closed Brayton cycle is proposed to recover the waste heat rejected from the precooler of a nuclear closed Brayton cycle in this paper. The detailed thermodynamic and economic analyses are carried out for the combined cycle. The effects of several important parameters, such as the absorber pressure, the turbine inlet pressure, the turbine inlet temperature, the ammonia mass fraction, and the ambient temperature, are investigated. The combined cycle performance is also optimized based on a multiobjective function. Compared with the closed Brayton cycle, the optimized power output and overall efficiency of the combined cycle are higher by 2.41% and 2.43%, respectively. The optimized LEC of the combined cycle is 0.73% lower than that of the closed Brayton cycle.

  15. Corrosion of Structural Materials for Advanced Supercritical Carbon- Dioxide Brayton Cycle

    Energy Technology Data Exchange (ETDEWEB)

    Sridharan, Kumar [Univ. of Wisconsin, Madison, WI (United States)

    2017-05-13

    The supercritical carbon-dioxide (referred to as SC-CO2 hereon) Brayton cycle is being considered for power conversion systems for a number of nuclear reactor concepts, including the sodium fast reactor (SFR), fluoride saltcooled high temperature reactor (FHR), and high temperature gas reactor (HTGR), and several types of small modular reactors (SMR). The SC-CO2 direct cycle gas fast reactor has also been recently proposed. The SC-CO2 Brayton cycle (discussed in Chapter 1) provides higher efficiencies compared to the Rankine steam cycle due to less compression work stemming from higher SC-CO2 densities, and allows for smaller components size, fewer components, and simpler cycle layout. For example, in the case of a SFR using a SC-CO2 Brayton cycle instead of a steam cycle would also eliminate the possibility of sodium-water interactions. The SC-CO2 cycle has a higher efficiency than the helium Brayton cycle, with the additional advantage of being able to operate at lower temperatures and higher pressures. In general, the SC-CO2 Brayton cycle is well-suited for any type of nuclear reactor (including SMR) with core outlet temperature above ~ 500°C in either direct or indirect versions. In all the above applications, materials corrosion in high temperature SC-CO2 is an important consideration, given their expected lifetimes of 20 years or longer. Our discussions with National Laboratories and private industry early on in this project indicated materials corrosion to be one of the significant gaps in the implementation of SC-CO2 Brayton cycle. Corrosion can lead to a loss of effective load-bearing wall thickness of a component and can potentially lead to the generation of oxide particulate debris which can lead to three-body wear in turbomachinery components. Another environmental degradation effect that is rather unique to CO2 environment is the possibility

  16. A study on the feasibility and a possible form of local residents participation in nuclear safety regulation

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Son, Moon Kyu; Kim, Seong Sook

    2003-02-01

    It is expected that the results of this study will help policy makers in the government and nuclear industry enhance the confidence of local residents and citizens in the safety of nuclear energy. It is also believed that the citizen confidence on the nuclear energy will help them implement nuclear policies more efficiently and more safely. Considering that the newly sworn-in government is to involve citizens in wide variety of policy areas, this study fits with the policy directions of the new government. Most importantly, desirable citizen participation in public decision-making is to contribute to the enhancement of the working democracy

  17. A study on the feasibility and a possible form of local residents participation in nuclear safety regulation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Hoon; Son, Moon Kyu [Korea Association for Nuclear Technology, Taejon (Korea, Republic of); Kim, Seong Sook [Shila Univ., Busan (Korea, Republic of)

    2003-02-15

    It is expected that the results of this study will help policy makers in the government and nuclear industry enhance the confidence of local residents and citizens in the safety of nuclear energy. It is also believed that the citizen confidence on the nuclear energy will help them implement nuclear policies more efficiently and more safely. Considering that the newly sworn-in government is to involve citizens in wide variety of policy areas, this study fits with the policy directions of the new government. Most importantly, desirable citizen participation in public decision-making is to contribute to the enhancement of the working democracy.

  18. Feasibility, tolerability and safety of pediatric hyperpolarized "1"2"9Xe magnetic resonance imaging in healthy volunteers and children with cystic fibrosis

    International Nuclear Information System (INIS)

    Walkup, Laura L.; Watters, Erin; Ruppert, Kai; Thomen, Robert P.; Woods, Jason C.; Akinyi, Teckla G.; Cleveland, Zackary I.; Clancy, John P.

    2016-01-01

    Hyperpolarized "1"2"9Xe is a promising contrast agent for MRI of pediatric lung function, but its safety and tolerability in children have not been rigorously assessed. To assess the feasibility, safety and tolerability of hyperpolarized "1"2"9Xe gas as an inhaled contrast agent for pediatric pulmonary MRI in healthy control subjects and in children with cystic fibrosis. Seventeen healthy control subjects (ages 6-15 years, 11 boys) and 11 children with cystic fibrosis (ages 8-16 years, 4 boys) underwent "1"2"9Xe MRI, receiving up to three doses of "1"2"9Xe gas prepared by either a commercially available or a homebuilt "1"2"9Xe polarizer. Subject heart rate and SpO_2 were monitored for 2 min post inhalation and compared to resting baseline values. Adverse events were reported via follow-up phone call at days 1 and 30 (range ±7 days) post-MRI. All children tolerated multiple doses of "1"2"9Xe, and no children withdrew from the study. Relative to baseline, most children who received a full dose of gas for imaging (10 of 12 controls and 8 of 11 children with cystic fibrosis) experienced a nadir in SpO_2 (mean -6.0 ± standard deviation 7.2%, P≤0.001); however within 2 min post inhalation SpO_2 values showed no significant difference from baseline (P=0.11). There was a slight elevation in heart rate (mean +6.6 ± 13.9 beats per minute [bpm], P=0.021), which returned from baseline within 2 min post inhalation (P=0.35). Brief side effects related to the anesthetic properties of xenon were mild and quickly resolved without intervention. No serious or severe adverse events were observed; in total, four minor adverse events (14.3%) were reported following "1"2"9Xe MRI, but all were deemed unrelated to the study. The feasibility, safety and tolerability of "1"2"9Xe MRI has been assessed in a small group of children as young as 6 years. SpO_2 changes were consistent with the expected physiological effects of a short anoxic breath-hold, and other mild side effects were

  19. Feasibility, tolerability and safety of pediatric hyperpolarized {sup 129}Xe magnetic resonance imaging in healthy volunteers and children with cystic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Walkup, Laura L.; Watters, Erin; Ruppert, Kai [Cincinnati Children' s Hospital Medical Center, Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati, OH (United States); Thomen, Robert P.; Woods, Jason C. [Cincinnati Children' s Hospital Medical Center, Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati, OH (United States); Washington University in St. Louis, Department of Physics, St. Louis, MO (United States); Akinyi, Teckla G.; Cleveland, Zackary I. [Cincinnati Children' s Hospital Medical Center, Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati, OH (United States); University of Cincinnati, Biomedical Engineering Program, Cincinnati, OH (United States); Clancy, John P. [Cincinnati Children' s Hospital Medical Center, Division of Pulmonary Medicine, Cincinnati, OH (United States)

    2016-11-15

    Hyperpolarized {sup 129}Xe is a promising contrast agent for MRI of pediatric lung function, but its safety and tolerability in children have not been rigorously assessed. To assess the feasibility, safety and tolerability of hyperpolarized {sup 129}Xe gas as an inhaled contrast agent for pediatric pulmonary MRI in healthy control subjects and in children with cystic fibrosis. Seventeen healthy control subjects (ages 6-15 years, 11 boys) and 11 children with cystic fibrosis (ages 8-16 years, 4 boys) underwent {sup 129}Xe MRI, receiving up to three doses of {sup 129}Xe gas prepared by either a commercially available or a homebuilt {sup 129}Xe polarizer. Subject heart rate and SpO{sub 2} were monitored for 2 min post inhalation and compared to resting baseline values. Adverse events were reported via follow-up phone call at days 1 and 30 (range ±7 days) post-MRI. All children tolerated multiple doses of {sup 129}Xe, and no children withdrew from the study. Relative to baseline, most children who received a full dose of gas for imaging (10 of 12 controls and 8 of 11 children with cystic fibrosis) experienced a nadir in SpO{sub 2} (mean -6.0 ± standard deviation 7.2%, P≤0.001); however within 2 min post inhalation SpO{sub 2} values showed no significant difference from baseline (P=0.11). There was a slight elevation in heart rate (mean +6.6 ± 13.9 beats per minute [bpm], P=0.021), which returned from baseline within 2 min post inhalation (P=0.35). Brief side effects related to the anesthetic properties of xenon were mild and quickly resolved without intervention. No serious or severe adverse events were observed; in total, four minor adverse events (14.3%) were reported following {sup 129}Xe MRI, but all were deemed unrelated to the study. The feasibility, safety and tolerability of {sup 129}Xe MRI has been assessed in a small group of children as young as 6 years. SpO{sub 2} changes were consistent with the expected physiological effects of a short anoxic breath

  20. SAFETY

    CERN Multimedia

    Niels Dupont

    2013-01-01

    CERN Safety rules and Radiation Protection at CMS The CERN Safety rules are defined by the Occupational Health & Safety and Environmental Protection Unit (HSE Unit), CERN’s institutional authority and central Safety organ attached to the Director General. In particular the Radiation Protection group (DGS-RP1) ensures that personnel on the CERN sites and the public are protected from potentially harmful effects of ionising radiation linked to CERN activities. The RP Group fulfils its mandate in collaboration with the CERN departments owning or operating sources of ionising radiation and having the responsibility for Radiation Safety of these sources. The specific responsibilities concerning "Radiation Safety" and "Radiation Protection" are delegated as follows: Radiation Safety is the responsibility of every CERN Department owning radiation sources or using radiation sources put at its disposition. These Departments are in charge of implementing the requi...

  1. Feasibility, Safety, and Efficacy of an Alternative Schedule of Sunitinib for the Treatment of Patients with Metastatic Renal Cell Carcinoma: A Retrospective Study.

    Science.gov (United States)

    Buti, Sebastiano; Donini, Maddalena; Bersanelli, Melissa; Gattara, Alessia; Leonardi, Francesco; Passalacqua, Rodolfo

    2017-12-01

    Standard treatment with sunitinib for patients with metastatic renal cancer provides an 'on-off' schedule (daily administration of a 50-mg capsule for 4 weeks, followed by a 2-week break; consecutive 6-week cycles). We developed an alternative intermittent schedule to reduce the toxicity and symptoms of tumor regrowth during the rest period and to allow prolonged continuation of therapy, maintaining dose intensity. The objective of this study was to provide a retrospective evaluation of the feasibility, safety, and efficacy of an alternative schedule of sunitinib in patients who did not tolerate classical treatment. Patients treated with the classical schedule with at least grade 2 toxicity or recurrence of symptoms during the rest period were switched to an alternative schedule (the same daily dose 5 consecutive days per week for 5 weeks and then the same daily dose on days 1, 3, and 5 in the sixth week; consecutive 6-week cycles). Twenty-five patients were enrolled. The median time from sunitinib initiation to schedule switch was 2.9 months. After the switch, the median therapy duration was 9.2 months. Rate of delay, corrected by cycle number, was 10% for both schedules. After the switch, 48.7% of patients obtained a toxicity reduction (hypertension -82%, stomatitis -71%, cutaneous toxicity -69%). A reduction in 'on-off symptoms' (-86%) was achieved. Overall response rate was 40% and the disease control rate was 80%. Median progression-free survival was 16.4 months and median overall survival was 41.3 months. Despite the small sample size and retrospective nature, we demonstrated the feasibility, safety, and efficacy of the alternative schedule, allowing prolonged treatment and better quality of life.

  2. Feasibility and safety of augmented-reality glass for computed tomography-assisted percutaneous revascularization of coronary chronic total occlusion: A single center prospective pilot study.

    Science.gov (United States)

    Opolski, Maksymilian P; Debski, Artur; Borucki, Bartosz A; Staruch, Adam D; Kepka, Cezary; Rokicki, Jakub K; Sieradzki, Bartosz; Witkowski, Adam

    2017-11-01

    Percutaneous coronary intervention (PCI) of chronic total occlusion (CTO) may be facilitated by projection of coronary computed tomography angiography (CTA) datasets in the catheterization laboratory. There is no data on the feasibility and safety outcomes of CTA-assisted CTO PCI using a wearable augmented-reality glass. A total of 15 patients scheduled for elective antegrade CTO intervention were prospectively enrolled and underwent preprocedural coronary CTA. Three-dimensional and curved multiplanar CT reconstructions were transmitted to a head-mounted hands-free computer worn by interventional cardiologists during CTO PCI to provide additional information on CTO tortuosity and calcification. The results of CTO PCI using a wearable computer were compared with a time-matched prospective angiographic registry of 59 patients undergoing antegrade CTO PCI without a wearable computer. Operators' satisfaction was assessed by a 5-point Likert scale. Mean age was 64 ± 8 years and the mean J-CTO score was 2.1 ± 0.9 in the CTA-assisted group. The voice-activated co-registration and review of CTA images in a wearable computer during CTO PCI were feasible and highly rated by PCI operators (4.7/5 points). There were no major adverse cardiovascular events. Compared with standard CTO PCI, CTA-assisted recanalization of CTO using a wearable computer showed more frequent selection of the first-choice stiff wire (0% vs 40%, p augmented-reality glass is feasible and safe, and might reduce the resources required for the interventional treatment of CTO. Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  3. Balanced Propofol Sedation in Patients Undergoing EUS-FNA: A Pilot Study to Assess Feasibility and Safety

    Directory of Open Access Journals (Sweden)

    N. Pagano

    2011-01-01

    Full Text Available Introduction and aims. Balanced propofol sedation (BPS administered by gastroenterologists has gained popularity in endoscopic procedures. Few studies exist about the safety of this approach during endosonography with fine needle aspiration (EUS-FNA. We assessed the safety of BPS in EUS-FNA. Materials and methods. 112 consecutive patients, referred to our unit to perform EUS-FNA, from February 2008 to December 2009, were sedated with BPS. A second gastroenterologist administered the drugs and monitorized the patient. Results. All the 112 patients (62 males, mean age 58.35 completed the examination. The mean dose of midazolam and propofol was, respectively, of 2.1 mg (range 1–4 mg and 350 mg (range 180–400. All patients received oxygen with a mean flux of 4 liter/minute (range 2–6 liters/minute. The mean recovery time after procedure was 25 minutes (range 18–45 minutes. No major complications related to sedation were registered during all procedures. The oxygen saturation of all patients never reduced to less than 85%. Blood systolic pressure during and after the procedure never reduced to less than 100 mmHg. Conclusions. In our experience BPS administered by non-anaesthesiologists provided safe and successful sedation in patients undergoing EUS-FNA.

  4. [Feasibility and relevance of an operating room safety checklist for developing countries: Study in a French hospital in Djibouti].

    Science.gov (United States)

    Becret, A; Clapson, P; Andro, C; Chapelier, X; Gauthier, J; Kaiser, E

    2013-01-01

    The use of the World Health Organization surgical safety checklist, mandatory in operating rooms (OR) in France, significantly reduces morbidity and mortality. Our objective was to evaluate the use of this checklist in the OR of a French military hospital in Djibouti (Horn of Africa). The study was performed in three stages: a retrospective evaluation of the checklist use over the previous two months, to assess the utilization and completeness rates; provision of information to the OR staff; and thereafter, prospective evaluation for a one-month period of checklist use, the reasons for non-compliance, and the cases in which the checklist identified errors and thus prevented serious adverse events. The initial utilization rate was 49%, with only 24% complete. After staff training and during the study these rates reached 100% and 99%. The staff encountered language difficulties in 53% of cases, and an interpreter was available for 81% of them. The capacity of the surgical safety checklist to detect serious adverse events was highlighted. The utilization and completeness rates were initially worse than those observed in metropolitan French ORs, but a simple staff information program was rapidly effective. Language difficulties are frequent but an interpreter is often available, unlike in developed countries where language problems are uncommon and the availability of interpreters difficult. Moreover, this study illustrates the ability of the checklist to detect and therefore prevent potentially serious adverse events.

  5. Use of an Anti-Gravity Treadmill for Early Postoperative Rehabilitation After Total Knee Replacement: A Pilot Study to Determine Safety and Feasibility.

    Science.gov (United States)

    Bugbee, William D; Pulido, Pamela A; Goldberg, Timothy; D'Lima, Darryl D

    2016-01-01

    The objective was to determine the safety, feasibility, and effects of anti-gravity gait training on functional outcomes (Knee Injury and Osteoarthritis Outcome Score [KOOS], the Timed Up and Go test [TUG], Numerical Rating Scale [NRS] for pain) with the AlterG® Anti-Gravity Treadmill® device for total knee arthroplasty (TKA) rehabilitation. Subjects (N = 30) were randomized to land-based vs anti-gravity gait training over 4 weeks of physical therapy after TKA. Adverse events, complications, and therapist satisfaction were recorded. All patients completed rehabilitation protocols without adverse events. KOOS, TUG, and NRS scores improved in both groups with no significant differences between groups. For the AlterG group, Sports/Recreation and Quality of Life subscales of the KOOS had the most improvement. At the end of physical therapy, TUG and NRS pain scores improved from 14 seconds to 8 seconds and from 2.8 to 1.1, respectively. Subjectively, therapists reported 100% satisfaction with the AlterG. This initial pilot study demonstrated that the AlterG Anti-Gravity Treadmill device was safe and feasible. While functional outcomes improved over time with use of the anti-gravity gait training, further studies are needed to define the role of this device as an alternative or adjunct to established rehabilitation protocols.

  6. Multimodal impairment-based physical therapy for the treatment of patients with post-concussion syndrome: A retrospective analysis on safety and feasibility.

    Science.gov (United States)

    Grabowski, Patrick; Wilson, John; Walker, Alyssa; Enz, Dan; Wang, Sijian

    2017-01-01

    Demonstrate implementation, safety and feasibility of multimodal, impairment-based physical therapy (PT) combining vestibular/oculomotor and cervical rehabilitation with sub-symptom threshold exercise for the treatment of patients with post-concussion syndrome (PCS). University hospital outpatient sports medicine facility. Twenty-five patients (12-20 years old) meeting World Health Organization criteria for PCS following sport-related concussion referred for supervised PT consisting of sub-symptom cardiovascular exercise, vestibular/oculomotor and cervical spine rehabilitation. Retrospective cohort. Post-Concussion Symptom Scale (PCSS) total score, maximum symptom-free heart rate (SFHR) during graded exercise testing (GXT), GXT duration, balance error scoring system (BESS) score, and number of adverse events. Patients demonstrated a statistically significant decreasing trend (p feasibility for future clinical trials to determine viable treatment approaches to reduce symptoms and improve function while avoiding negative repercussions of physical inactivity and premature return to full activity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Feasibility and safety of robot-assisted thoracic surgery for lung lobectomy in patients with non-small cell lung cancer: a systematic review and meta-analysis.

    Science.gov (United States)

    Wei, Shiyou; Chen, Minghao; Chen, Nan; Liu, Lunxu

    2017-05-08

    The aim of this study is to evaluate the feasibility and safety of robot-assisted thoracic surgery (RATS) lobectomy versus video-assisted thoracic surgery (VATS) for lobectomy in patients with non-small cell lung cancer (NSCLC). An electronic search of six electronic databases was performed to identify relevant comparative studies. Meta-analysis was performed by pooling the results of reported incidence of overall morbidity, mortality, prolonged air leak, arrhythmia, and pneumonia between RATS and VATS lobectomy. Subgroup analysis was also conducted based on matched and unmatched cohort studies, if possible. Relative risks (RR) with their 95% confidence intervals (CI) were calculated by means of Revman version 5.3. Twelve retrospective cohort studies were included, with a total of 60,959 patients. RATS lobectomy significantly reduced the mortality rate when compared with VATS lobectomy (RR = 0.54, 95% CI 0.38-0.77; P = 0.0006), but this was not consistent with the pooled result of six matched studies (RR = 0.12, 95% CI 0.01-1.07; P = 0.06). There was no significant difference in morbidity between the two approaches (RR = 0.97, 95% CI 0.85-1.12; P = 0.70). RATS lobectomy is a feasible and safe technique and can achieve an equivalent short-term surgical efficacy when compared with VATS, but its cost effectiveness also should be taken into consideration.

  8. Feasibility and Safety of Local Treatment with Recombinant Human Tissue Factor Pathway Inhibitor in a Rat Model of Streptococcus pneumoniae Pneumonia.

    Directory of Open Access Journals (Sweden)

    Florry E van den Boogaard

    Full Text Available Pulmonary coagulopathy is intrinsic to pulmonary injury including pneumonia. Anticoagulant strategies could benefit patients with pneumonia, but systemic administration of anticoagulant agents may lead to suboptimal local levels and may cause systemic hemorrhage. We hypothesized nebulization to provide a safer and more effective route for local administration of anticoagulants. Therefore, we aimed to examine feasibility and safety of nebulization of recombinant human tissue factor pathway inhibitor (rh-TFPI in a well-established rat model of Streptococcus (S. pneumoniae pneumonia. Thirty minutes before and every 6 hours after intratracheal instillation of S. pneumonia causing pneumonia, rats were subjected to local treatment with rh-TFPI or placebo, and sacrificed after 42 hours. Pneumonia was associated with local as well as systemic activation of coagulation. Nebulization of rh-TFPI resulted in high levels of rh-TFPI in bronchoalveolar lavage fluid, which was accompanied by an attenuation of pulmonary coagulation. Systemic rh-TFPI levels remained undetectable, and systemic TFPI activity and systemic coagulation were not affected. Histopathology revealed no bleeding in the lungs. We conclude that nebulization of rh-TFPI seems feasible and safe; local anticoagulant treatment with rh-TFPI attenuates pulmonary coagulation, while not affecting systemic coagulation in a rat model of S. pneumoniae pneumonia.

  9. The introduction of the safety of molten salt reactor

    International Nuclear Information System (INIS)

    Zuo Jiaxu; Zhang Chunming

    2011-01-01

    This paper introduces the generation TV Nuclear Energy Systems and molten salt reactor which is the only fluid fuel reactor in the Gen-TV. Safety features and attributes of MSR are described. The supply of fuel and the minimum of waste are described. The clean molten salt in the secondary heat transport system transfers the heat from the primary heat exchanger to a high-temperature Brayton cycle that converts the heat to electricity. With the Brayton cycle, the thermal efficiency of the system will be improved. Base on the MSR, the thorium-uranium fuel cycle is also introduced. (authors)

  10. Community-Based Adaptive Physical Activity Program for Chronic Stroke: Feasibility, Safety, and Efficacy of the Empoli Model

    Science.gov (United States)

    Stuart, Mary; Benvenuti, Francesco; Macko, Richard; Taviani, Antonio; Segenni, Lucianna; Mayer, Federico; Sorkin, John D.; Stanhope, Steven J.; Macellari, Velio; Weinrich, Michael

    2010-01-01

    Objective To determine whether Adaptive Physical Activity (APA-stroke), a community-based exercise program for participants with hemiparetic stroke, improves function in the community. Methods Nonrandomized controlled study in Tuscany, Italy, of participants with mild to moderate hemiparesis at least 9 months after stroke. Forty-nine participants in a geographic health authority (Empoli) were offered APA-stroke (40 completed the study). Forty-four control participants in neighboring health authorities (Florence and Pisa) received usual care (38 completed the study). The APA intervention was a community-based progressive group exercise regimen that included walking, strength, and balance training for 1 hour, thrice a week, in local gyms, supervised by gym instructors. No serious adverse clinical events occurred during the exercise intervention. Outcome measures included the following: 6-month change in gait velocity (6-Minute Timed Walk), Short Physical Performance Battery (SPPB), Berg Balance Scale, Stroke Impact Scale (SIS), Barthel Index, Hamilton Rating Scale for Depression, and Index of Caregivers Strain. Results After 6 months, the intervention group improved whereas controls declined in gait velocity, balance, SPPB, and SIS social participation domains. These between-group comparisons were statistically significant at P glucose tolerance tests were performed on a subset of participants in the intervention group. For these individuals, insulin secretion declined 29% after 6 months (P = .01). Conclusion APA-stroke appears to be safe, feasible, and efficacious in a community setting. PMID:19318465

  11. Intra-Target Microdosing - A Novel Drug Development Approach: Proof of Concept, Safety, and Feasibility Study in Humans.

    Science.gov (United States)

    Burt, T; MacLeod, D; Lee, K; Santoro, A; DeMasi, D K; Hawk, T; Feinglos, M; Rowland, M; Noveck, R J

    2017-09-01

    Intra-Target Microdosing (ITM) is a novel drug development approach aimed at increasing the efficiency of first-in-human (FIH) testing of new molecular entities (NMEs). ITM combines intra-target drug delivery and "microdosing," the subpharmacological systemic exposure. We hypothesized that when the target tissue is small (about 1/100th of total body mass), ITM can lead to target therapeutic-level exposure with minimal (microdose) systemic exposure. Each of five healthy male volunteers received insulin microdose into the radial artery or full therapeutic dose intravenously in separate visits. Insulin and glucose levels were similar between systemic administration and ITM administration in the ipsilateral hand, and glucose levels demonstrated a reduction in the ipsilateral hand but not in the contralateral hand. Positron emission tomography (PET) imaging of 18 F-fluorodeoxyglucose (FDG) uptake demonstrated differences between the ipsilateral and contralateral arms. The procedures were safe and well-tolerated. Results are consistent with ITM proof-of-concept (POC) and demonstrate the ethical, regulatory, and logistical feasibility of the approach. © 2017 The Authors. Clinical and Translational Science published by Wiley Periodicals, Inc. on behalf of American Society for Clinical Pharmacology and Therapeutics.

  12. Intra‐Target Microdosing – A Novel Drug Development Approach: Proof of Concept, Safety, and Feasibility Study in Humans

    Science.gov (United States)

    MacLeod, D; Lee, K; Santoro, A; DeMasi, DK; Hawk, T; Feinglos, M; Rowland, M; Noveck, RJ

    2017-01-01

    Abstract Intra‐Target Microdosing (ITM) is a novel drug development approach aimed at increasing the efficiency of first‐in‐human (FIH) testing of new molecular entities (NMEs). ITM combines intra‐target drug delivery and “microdosing,” the subpharmacological systemic exposure. We hypothesized that when the target tissue is small (about 1/100th of total body mass), ITM can lead to target therapeutic‐level exposure with minimal (microdose) systemic exposure. Each of five healthy male volunteers received insulin microdose into the radial artery or full therapeutic dose intravenously in separate visits. Insulin and glucose levels were similar between systemic administration and ITM administration in the ipsilateral hand, and glucose levels demonstrated a reduction in the ipsilateral hand but not in the contralateral hand. Positron emission tomography (PET) imaging of 18F‐fluorodeoxyglucose (FDG) uptake demonstrated differences between the ipsilateral and contralateral arms. The procedures were safe and well‐tolerated. Results are consistent with ITM proof‐of‐concept (POC) and demonstrate the ethical, regulatory, and logistical feasibility of the approach. PMID:28689370

  13. Can exercise suppress tumour growth in advanced prostate cancer patients with sclerotic bone metastases? A randomised, controlled study protocol examining feasibility, safety and efficacy.

    Science.gov (United States)

    Hart, Nicolas H; Newton, Robert U; Spry, Nigel A; Taaffe, Dennis R; Chambers, Suzanne K; Feeney, Kynan T; Joseph, David J; Redfern, Andrew D; Ferguson, Tom; Galvão, Daniel A

    2017-05-30

    Exercise may positively alter tumour biology through numerous modulatory and regulatory mechanisms in response to a variety of modes and dosages, evidenced in preclinical models to date. Specifically, localised and systemic biochemical alterations produced during and following exercise may suppress tumour formation, growth and distribution by virtue of altered epigenetics and endocrine-paracrine activity. Given the impressive ability of targeted mechanical loading to interfere with metastasis-driven tumour formation in human osteolytic tumour cells, it is of equal interest to determine whether a similar effect is observed in sclerotic tumour cells. The study aims to (1) establish the feasibility and safety of a combined modular multimodal exercise programme with spinal isometric training in advanced prostate cancer patients with sclerotic bone metastases and (2) examine whether targeted and supervised exercise can suppress sclerotic tumour growth and activity in spinal metastases in humans. A single-blinded, two-armed, randomised, controlled and explorative phase I clinical trial combining spinal isometric training with a modular multimodal exercise programme in 40 men with advanced prostate cancer and stable sclerotic spinal metastases. Participants will be randomly assigned to (1) the exercise intervention or (2) usual medical care. The intervention arm will receive a 3-month, supervised and individually tailored modular multimodal exercise programme with spinal isometric training. Primary endpoints (feasibility and safety) and secondary endpoints (tumour morphology; biomarker activity; anthropometry; musculoskeletal health; adiposity; physical function; quality of life; anxiety; distress; fatigue; insomnia; physical activity levels) will be measured at baseline and following the intervention. Statistical analyses will include descriptive characteristics, t-tests, effect sizes and two-way (group × time) repeated-measures analysis of variance (or analysis of

  14. Safety

    International Nuclear Information System (INIS)

    2001-01-01

    This annual report of the Senior Inspector for the Nuclear Safety, analyses the nuclear safety at EDF for the year 1999 and proposes twelve subjects of consideration to progress. Five technical documents are also provided and discussed concerning the nuclear power plants maintenance and safety (thermal fatigue, vibration fatigue, assisted control and instrumentation of the N4 bearing, 1300 MW reactors containment and time of life of power plants). (A.L.B.)

  15. Feasibility, safety and cost of outpatient management of acute minor ischaemic stroke: a population-based study.

    Science.gov (United States)

    Paul, Nicola L M; Koton, Silvia; Simoni, Michela; Geraghty, Olivia C; Luengo-Fernandez, Ramon; Rothwell, Peter M

    2013-03-01

    Outpatient management safely and effectively prevents early recurrent stroke after transient ischaemic attack (TIA), but this approach may not be safe in patients with acute minor stroke. To study outcomes of clinic and hospital-referred patients with TIA or minor stroke (National Institute of Health Stroke Scale score ≤3) in a prospective, population-based study (Oxford Vascular Study). Of 845 patients with TIA/stroke, 587 (69%) were referred directly to outpatient clinics and 258 (31%) directly to inpatient services. Of the 250 clinic-referred minor strokes (mean age 72.7 years), 237 (95%) were investigated, treated and discharged on the same day, of whom 16 (6.8%) were subsequently admitted to hospital within 30 days for recurrent stroke (n=6), sepsis (n=3), falls (n=3), bleeding (n=2), angina (n=1) and nursing care (n=1). The 150 patients (mean age 74.8 years) with minor stroke referred directly to hospital (median length-of-stay 9 days) had a similar 30-day readmission rate (9/150; 6.3%; p=0.83) after initial discharge and a similar 30-day risk of recurrent stroke (9/237 in clinic patients vs 8/150, OR=0.70, 0.27-1.80, p=0.61). Rates of prescription of secondary prevention medication after initial clinic/hospital discharge were higher in clinic-referred than in hospital-referred patients for antiplatelets/anticoagulants (phospital-referred minor stroke versus £743 (1794) for clinic-referred cases. Outpatient management of clinic-referred minor stroke is feasible and may be as safe as inpatient care. Rates of early hospital admission and recurrent stroke were low and uptake and maintenance of secondary prevention was high.

  16. Prospective drug safety monitoring using the UK primary-care General Practice Research Database: theoretical framework, feasibility analysis and extrapolation to future scenarios.

    Science.gov (United States)

    Johansson, Saga; Wallander, Mari-Ann; de Abajo, Francisco J; García Rodríguez, Luis Alberto

    2010-03-01

    Post-launch drug safety monitoring is essential for the detection of adverse drug signals that may be missed during preclinical trials. Traditional methods of postmarketing surveillance such as spontaneous reporting have intrinsic limitations, many of which can be overcome by the additional application of structured pharmacoepidemiological approaches. However, further improvement in drug safety monitoring requires a shift towards more proactive pharmacoepidemiological methods that can detect adverse drug signals as they occur in the population. To assess the feasibility of using proactive monitoring of an electronic medical record system, in combination with an independent endpoint adjudication committee, to detect adverse events among users of selected drugs. UK General Practice Research Database (GPRD) information was used to detect acute liver disorder associated with the use of amoxicillin/clavulanic acid (hepatotoxic) or low-dose aspirin (acetylsalicylic acid [non-hepatotoxic]). Individuals newly prescribed these drugs between 1 October 2005 and 31 March 2006 were identified. Acute liver disorder cases were assessed using GPRD computer records in combination with case validation by an independent endpoint adjudication committee. Signal generation thresholds were based on the background rate of acute liver disorder in the general population. Over a 6-month period, 8148 patients newly prescribed amoxicillin/clavulanic acid and 5577 patients newly prescribed low-dose aspirin were identified. Within this cohort, searches identified 11 potential liver disorder cases from computerized records: six for amoxicillin/clavulanic acid and five for low-dose aspirin. The independent endpoint adjudication committee refined this to four potential acute liver disorder cases for whom paper-based information was requested for final case assessment. Final case assessments confirmed no cases of acute liver disorder. The time taken for this study was 18 months (6 months for

  17. Preliminary design study of an alternate heat source assembly for a Brayton isotope power system

    Science.gov (United States)

    Strumpf, H. J.

    1978-01-01

    Results are presented for a study of the preliminary design of an alternate heat source assembly (HSA) intended for use in the Brayton isotope power system (BIPS). The BIPS converts thermal energy emitted by a radioactive heat source into electrical energy by means of a closed Brayton cycle. A heat source heat exchanger configuration was selected and optimized. The design consists of a 10 turn helically wound Hastelloy X tube. Thermal analyses were performed for various operating conditions to ensure that post impact containment shell (PICS) temperatures remain within specified limits. These limits are essentially satisfied for all modes of operation except for the emergency cooling system for which the PICS temperatures are too high. Neon was found to be the best choice for a fill gas for auxiliary cooling system operation. Low cycle fatigue life, natural frequency, and dynamic loading requirements can be met with minor modifications to the existing HSA.

  18. Research on the Development of the Supercritical CO{sub 2} Dual Brayton Cycle

    Energy Technology Data Exchange (ETDEWEB)

    Baik, Young-Jin; Na, Sun Ik; Cho, Junhyun; Shin, Hyung-Ki; Lee, Gilbong [Korea Institute of Energy Research (KIER), Daejeon (Korea, Republic of)

    2016-10-15

    Because of the growing interest in supercritical carbon dioxide power cycle technology owing to its potential enhancement in compactness and efficiency, supercritical carbon dioxide cycles have been studied in the fields of nuclear power, concentrated solar power (CSP), and fossil fuel power generation. This study introduces the current status of the research project on the supercritical carbon dioxide power cycle by Korea Institute of Energy Research (KIER). During the first phase of the project, the un-recuperated supercritical Brayton cycle test loop was built and tested. In phase two, researchers are designing and building a supercritical carbon dioxide dual Brayton cycle, which utilizes two turbines and two recuperators. Under the simulation condition considered in this study, it was confirmed that the design parameter has an optimal value for maximizing the net power in the supercritical carbon dioxide dual cycle.

  19. Supercritical carbon dioxide Brayton power conversion cycle for battery optimized reactor integral system

    International Nuclear Information System (INIS)

    Kim, T. W.; Kim, N. H.; Suh, K. Y.

    2007-01-01

    Supercritical carbon dioxide (SCO 2 ) promises a high power conversion efficiency of the recompression Brayton cycle due to its excellent compressibility reducing the compression work at the bottom of the cycle and to a higher density than helium or steam decreasing the component size. The SCO 2 Brayton cycle efficiency as high as 45% furnishes small sized nuclear reactors with economical benefits on the plant construction and maintenance. A 23 MWth lead-cooled Battery Optimized Reactor Integral System (BORIS) is being developed as an ultra-long-life, versatile-purpose, fast-spectrum reactor. BORIS is coupled to the SCO 2 Brayton cycle needing less room relative to the Rankine steam cycle because of its smaller components. The SCO 2 Brayton cycle of BORIS consists of a 16 MW turbine, a 32 MW high temperature recuperator, a 14 MW low temperature recuperator, an 11 MW precooler and 2 and 2.8 MW compressors. Entering six heat exchangers between primary and secondary system at 19.9 MPa and 663 K, the SCO 2 leaves the heat exchangers at 19.9 MPa and 823 K. The promising secondary system efficiency of 45% was calculated by a theoretical method in which the main parameters include pressure, temperature, heater power, the turbine's, recuperators' and compressors' efficiencies, and the flow split ratio of SCO 2 going out from the low temperature recuperator. Development of Modular Optimized Brayton Integral System (MOBIS) is being devised as the SCO 2 Brayton cycle energy conversion cycle for BORIS. MOBIS consists of Loop Operating Brayton Optimization Study (LOBOS) for experimental Brayton cycle loop and Gas Advanced Turbine Operation Study (GATOS) for the SCO 2 turbine. Liquid-metal Energy Exchanger Integral System (LEXIS) serves to couple BORIS and MOBIS. LEXIS comprises Physical Aspect Thermal Operation System (PATOS) for SCO 2 thermal hydraulic characteristics, Shell-and-tube Overall Layout Optimization Study (SOLOS) for shell-and-tube heat exchanger, Printed

  20. A comparison of radioisotope Brayton and Stirling system for lunar surface mobile power

    International Nuclear Information System (INIS)

    Harty, R.B.

    1991-01-01

    A study was performed by the Rocketdyne Division of Rockwell 2.5-kWe modular dynamic isotope power system (DIPS) using a Stirling power conversion system. The results of this study were compared with similar results performed under the DIPS program using a Brayton power conversion system. The study indicated that the Stirling power module has 20% lower mass and 40% lower radiator area than the Brayton module. However, the study also revealed that because the Stirling power module requires a complex heat pipe arrangment to transport heat from the isotope to the Stirling heater head and a pumped NaK heat rejection loop, the Stirling module is much more difficult to integrate with the isotope heat source and heat rejection system

  1. Transportation Safety of Lithium Iron Phosphate Batteries - A Feasibility Study of Storing at Very Low States of Charge.

    Science.gov (United States)

    Barai, Anup; Uddin, Kotub; Chevalier, Julie; Chouchelamane, Gael H; McGordon, Andrew; Low, John; Jennings, Paul

    2017-07-11

    In freight classification, lithium-ion batteries are classed as dangerous goods and are therefore subject to stringent regulations and guidelines for certification for safe transport. One such guideline is the requirement for batteries to be at a state of charge of 30%. Under such conditions, a significant amount of the battery's energy is stored; in the event of mismanagement, or indeed an airside incident, this energy can lead to ignition and a fire. In this work, we investigate the effect on the battery of removing 99.1% of the total stored energy. The performance of 8Ah C 6 /LiFePO 4 pouch cells were measured following periods of calendar ageing at low voltages, at and well below the manufacturer's recommended value. Battery degradation was monitored using impedance spectroscopy and capacity tests; the results show that the cells stored at 2.3 V exhibited no change in cell capacity after 90 days; resistance rise was negligible. Energy-dispersive X-ray spectroscopy results indicate that there was no significant copper dissolution. To test the safety of the batteries at low voltages, external short-circuit tests were performed on the cells. While the cells discharged to 2.3 V only exhibited a surface temperature rise of 6 °C, cells at higher voltages exhibited sparks, fumes and fire.

  2. Feasibility and Design of an Electronic Surgical Safety Checklist in a Teaching Hospital: A User-Based Approach.

    Science.gov (United States)

    Kiefel, Karin; Donsa, Klaus; Tiefenbacher, Peter; Mischak, Robert; Brunner, Gernot; Sendlhofer, Gerald; Pieber, Thomas

    2018-01-01

    The Surgical Safety Checklist (SSC) is routinely used in operating rooms (OR) but its acceptance is low. One promising way to improve acceptance of the SSC and thus quality of patient care is digitalization. To investigate how a digitalization of the SSC could be implemented in a teaching hospital. Based on the identified user requirements we designed a first user interface (UI). We performed a literature review, identified user perceptions and requirements during 12 interviews including a standardized questionnaire in surgical departments at the University Hospital Graz (Austria). Subsequently a first prototype of a UI was designed. Seven different approaches for digital SSC were identified in literature. Our interviews showed that 90% of the participants had a positive attitude towards a digitalization of SSC. The most favoured version of a digitalized SSC was a tablet-based client-server system with integration in the EHR and projection on an OR monitor. Digitalization of the SSC is requested by medical and nursing personnel. Based on the identified user requirements we designed a process oriented UI of a digital SSC.

  3. Stereotactic body radiation therapy for liver metastases from colorectal cancer: analysis of safety, feasibility, and early outcomes

    Directory of Open Access Journals (Sweden)

    Marie-Adele Sorel Kress

    2012-02-01

    Full Text Available Introduction: Colorectal cancer (CRC is the 3rd leading cause of cancer-related death in the U.S. Many patients with CRC develop hepatic metastases as the sole site of metastases. Historical treatment options were limited to resection or conventional radiation therapy. Stereotactic body radiation therapy (SBRT has emerged as a rational treatment approach. This study reviews our experience with SBRT for patients with liver metastases from CRC.Material and Methods: Fourteen histologically confirmed hepatic CRC metastases in 11 consecutive patients were identified between November, 2004 and June, 2009 at Georgetown University. All patients underwent CT-based treatment planning; a few also had MRI or PET/CT. All patients had fiducial markers placed under CT guidance and were treated using the CyberKnife system. Treatment response and toxicities were examined; survival and local control were evaluated.Results: Most patients were treated to a single hepatic lesion (n=8, with a few treated to 2 lesions (n=3. Median treatment volume was 99.7 cm3, and lesions were treated to a median BED10 of 49.7 Gy (range: 28 – 100.8 Gy. Median follow-up was 21 months; median survival was 16.1 months, with 2-year actuarial survival of 25.7%. One-year local control was 72%. Among patients with post-treatment imaging, 8 had stable disease (80% and 2 had progressive disease (20% at first follow-up. The most common grade 1-2 acute toxicities included nausea and alterations in liver function tests; there was one grade 3 toxicity (elevated bilirubin, and no grade 4-5 toxicities.Discussion: SBRT is safe and feasible for the treatment of limited hepatic metastases from CRC. Our results compare favorably with outcomes from previous studies of SBRT. Further studies are needed to better define patient eligibility, study the role of combined modality treatment, optimize treatment parameters, and characterize quality of life after treatment.

  4. Preliminary design of S-CO{sub 2} Brayton cycle for APR-1400 with power generation and desalination process

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Seong Jun; Lee, Won Woong; Jeong, Yong Hoon; Lee, Jeong Ik [KAIST, Daejeon (Korea, Republic of); Yoon, Ho Joon [KUSTAR, Abu Dhabi (United Arab Emirates)

    2015-10-15

    This study was conducted to explore the capabilities of the S-CO{sub 2} Brayton cycle for a cogeneration system for APR-1400 application. Three concepts of the S-CO{sub 2} simple recuperated co-generation cycle were designed. A supercritical CO{sub 2} (S-CO{sub 2}) Brayton cycle is recently receiving significant attention as a promising power conversion system in wide range of energy applications due to its high efficiency and compact footprint. The main reason why the S-CO{sub 2} Brayton cycle has these advantages is that the compressor operates near the critical point of CO{sub 2} (30.98 .deg. C, 7.38MPa) to reduce the compression work significantly compared to the other Brayton cycles. In this study, the concept of replacing the entire steam cycle of APR-1400 with the S-CO{sub 2} Brayton cycle is evaluated. The power generation purpose S-CO{sub 2} Brayton cycles are redesigned to generate power and provide heat to the desalination system at the same time. The performance of these newly suggested cycles are evaluated in this paper. The target was to deliver 147MW heat to the desalination process. The thermal efficiencies of the three concepts are not significantly different, but the 3{sup rd} concept is relatively simpler than other cycles because only an additional heat exchanger is required. Although the 2{sup nd} concept is relatively complicated in comparison to other concepts, the temperatures at the inlet and outlet of the DHX are higher than that of the others. As shown in the results, the S-CO{sub 2} Brayton cycles are not easy to outperform the steam cycle with very simple layout and general design points under APR-1400 operating condition. However, this study shows that the S-CO{sub 2} Brayton cycles can be designed as a co-generation cycle while producing the target desalination heat with a simple configuration. In addition, it was also found that the S-CO{sub 2} Brayton cycle can achieve higher cycle thermal efficiency than the steam power cycle under

  5. Design and analysis of Helium Brayton cycle for energy conversion system of RGTT200K

    International Nuclear Information System (INIS)

    Ignatius Djoko Irianto

    2016-01-01

    The helium Brayton cycle for the design of cogeneration energy conversion system for RGTT200K have been analyzed to obtain the higher thermal efficiency and energy utilization factor. The aim of this research is to analyze the potential of the helium Brayton cycle to be implemented in the design of cogeneration energy conversion system of RGTT200K. Three configuration models of cogeneration energy conversion systems have been investigated. In the first configuration model, an intermediate heat exchanger (IHX) is installed in series with the gas turbine, while in the second configuration model, IHX and gas turbines are installed in parallel. The third configuration model is similar to the first configuration, but with two compressors. Performance analysis of Brayton cycle used for cogeneration energy conversion system of RGTT200K has been done by simulating and calculating using CHEMCAD code. The simulation result shows that the three configuration models of cogeneration energy conversion system give the temperature of thermal energy in the secondary side of IHX more than 800 °C at the reactor coolant mass flow rate of 145 kg/s. Nevertheless, the performance parameters, which include thermal efficiency and energy utilization factor (EUF), are different for each configuration model. By comparing the performance parameter in the three configurations of helium Brayton cycle for cogeneration energy conversion systems RGTT200K, it is found that the energy conversion system with a first configuration has the highest thermal efficiency and energy utilization factor (EUF). Thermal efficiency and energy utilization factor for the first configuration of the reactor coolant mass flow rate of 145 kg/s are 35.82 % and 80.63 %. (author)

  6. Loop containment (joint integrity) assessment Brayton Isotope Power System flight system

    International Nuclear Information System (INIS)

    1976-01-01

    The Brayton Isotope Power System (BIPS) contains a large number of joints. Since the failure of a joint would result in loss of the working fluid and consequential failure of the BIPS, the integrity of the joints is of paramount importance. The reliability of the ERDA BIPS loop containment (joint integrity) is evaluated. The conceptual flight system as presently configured is depicted. A brief description of the flight system is given

  7. Preheating of fluid in a supercritical Brayton cycle power generation system at cold startup

    Science.gov (United States)

    Wright, Steven A.; Fuller, Robert L.

    2016-07-12

    Various technologies pertaining to causing fluid in a supercritical Brayton cycle power generation system to flow in a desired direction at cold startup of the system are described herein. A sensor is positioned at an inlet of a turbine, wherein the sensor is configured to output sensed temperatures of fluid at the inlet of the turbine. If the sensed temperature surpasses a predefined threshold, at least one operating parameter of the power generation system is altered.

  8. Supercritical CO2 Brayton Cycle Energy Conversion System Coupled with SFR

    International Nuclear Information System (INIS)

    Cha, Jae Eun; Kim, S. O.; Seong, S. H.; Eoh, J. H.; Lee, T. H.; Choi, S. K.; Han, J. W.; Bae, S. W.

    2008-12-01

    This report contains the description of the S-CO 2 Brayton cycle coupled to KALIMER-600 as an alternative energy conversion system. For a system development, a computer code was developed to calculate heat balance of normal operation condition. Based on the computer code, the S-CO 2 Brayton cycle energy conversion system was constructed for the KALIMER-600. Computer codes were developed to analysis for the S-CO 2 turbomachinery. Based on the design codes, the design parameters were prepared to configure the KALIMER-600 S-CO 2 turbomachinery models. A one-dimensional analysis computer code was developed to evaluate the performance of the previous PCHE heat exchangers and a design data for the typical type PCHE was produced. In parallel with the PCHE-type heat exchanger design, an airfoil shape fin PCHE heat exchanger was newly designed. The new design concept was evaluated by three-dimensional CFD analyses. Possible control schemes for power control in the KALIMER-600 S-CO 2 Brayton cycle were investigated by using the MARS code. The MMS-LMR code was also developed to analyze the transient phenomena in a SFR with a supercritical CO 2 Brayton cycle to develop the control logic. Simple power reduction and recovery event was selected and analyzed for the transient calculation. For the evaluation of Na-CO 2 boundary failure event, a computer was developed to simulate the complex thermodynamic behaviors coupled with the chemical reaction between liquid sodium and CO 2 gas. The long term behavior of a Na-CO 2 boundary failure event and its consequences which lead to a system pressure transient were evaluated

  9. Integration between direct steam generation in linear solar collectors and supercritical carbon dioxide Brayton power cycles

    OpenAIRE

    Coco Enríquez, Luis; Muñoz Antón, Javier; Martínez-Val Peñalosa, José María

    2015-01-01

    Direct Steam Generation in Parabolic Troughs or Linear Fresnel solar collectors is a technology under development since beginning of nineties (1990's) for replacing thermal oils and molten salts as heat transfer fluids in concentrated solar power plants, avoiding environmental impacts. In parallel to the direct steam generation technology development, supercritical Carbon Dioxide Brayton power cycles are maturing as an alternative to traditional Rankine cycles for increasing net plant efficie...

  10. The Safety and Feasibility of Image-Guided BrainPath-Mediated Transsulcul Hematoma Evacuation: A Multicenter Study.

    Science.gov (United States)

    Labib, Mohamed A; Shah, Mitesh; Kassam, Amin B; Young, Ronald; Zucker, Lloyd; Maioriello, Anthony; Britz, Gavin; Agbi, Charles; Day, J D; Gallia, Gary; Kerr, Robert; Pradilla, Gustavo; Rovin, Richard; Kulwin, Charles; Bailes, Julian

    2017-04-01

    Subcortical injury resulting from conventional surgical management of intracranial hemorrhage may counteract the potential benefits of hematoma evacuation. To evaluate the safety and potential benefits of a novel, minimally invasive approach for clot evacuation in a multicenter study. The integrated approach incorporates 5 competencies: (1) image interpretation and trajectory planning, (2) dynamic navigation, (3) atraumatic access system (BrainPath, NICO Corp, Indianapolis, Indiana), (4) extracorporeal optics, and (5) automated atraumatic resection. Twelve neurosurgeons from 11 centers were trained to use this approach through a continuing medical education-accredited course. Demographical, clinical, and radiological data of patients treated over 2 years were analyzed retrospectively. Thirty-nine consecutive patients were identified. The median Glasgow Coma Scale (GCS) score at presentation was 10 (range, 5-15). The thalamus/basal ganglion regions were involved in 46% of the cases. The median hematoma volume and depth were 36 mL (interquartile range [IQR], 27-65 mL) and 1.4 cm (IQR, 0.3-2.9 cm), respectively. The median time from ictus to surgery was 24.5 hours (IQR, 16-66 hours). The degree of hematoma evacuation was ≥90%, 75% to 89%, and 50% to 74% in 72%, 23%, and 5.0% of the patients, respectively. The median GCS score at discharge was 14 (range, 8-15). The improvement in GCS score was statistically significant ( P < .001). Modified Rankin Scale data were available for 35 patients. Fifty-two percent of those patients had a modified Rankin Scale score of ≤2. There were no mortalities. The approach was safely performed in all patients with a relatively high rate of clot evacuation and functional independence. Copyright © 2016 by the Congress of Neurological Surgeons

  11. Nuclear reactor closed Brayton cycle power conversion system optimization trends for extra-terrestrial applications

    International Nuclear Information System (INIS)

    Ashe, T.L.; Baggenstoss, W.G.; Bons, R.

    1990-01-01

    Extra-terrestrial exploration and development missions of the next century will require reliable, low-mass power generation modules of 100 kW e and more. These modules will be required to support both fixed-base and manned rover/explorer power needs. Low insolation levels at and beyond Mars and long periods of darkness on the moon make solar conversion less desirable for surface missions. For these missions, a closed Brayton cycle energy conversion system coupled with a reactor heat source is a very attractive approach. The authors conducted parametric studies to assess optimized system design trends for nuclear-Brayton systems as a function of operating environment and user requirements. The inherent design flexibility of the closed Brayton cycle energy conversion system permits ready adaptation of the system to future design constraints. This paper describes a dramatic contrast between system designs requiring man-rated shielding. The paper also considers the ramification of using indigenous materials to provide reactor shielding for a fixed-base power source

  12. Coupling a Supercritical Carbon Dioxide Brayton Cycle to a Helium-Cooled Reactor.

    Energy Technology Data Exchange (ETDEWEB)

    Middleton, Bobby [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Pasch, James Jay [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Kruizenga, Alan Michael [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Walker, Matthew [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2016-01-01

    This report outlines the thermodynamics of a supercritical carbon dioxide (sCO2) recompression closed Brayton cycle (RCBC) coupled to a Helium-cooled nuclear reactor. The baseline reactor design for the study is the AREVA High Temperature Gas-Cooled Reactor (HTGR). Using the AREVA HTGR nominal operating parameters, an initial thermodynamic study was performed using Sandia's deterministic RCBC analysis program. Utilizing the output of the RCBC thermodynamic analysis, preliminary values of reactor power and of Helium flow rate through the reactor were calculated in Sandia's HelCO2 code. Some research regarding materials requirements was then conducted to determine aspects of corrosion related to both Helium and to sCO2 , as well as some mechanical considerations for pressures and temperatures that will be seen by the piping and other components. This analysis resulted in a list of materials-related research items that need to be conducted in the future. A short assessment of dry heat rejection advantages of sCO2> Brayton cycles was also included. This assessment lists some items that should be investigated in the future to better understand how sCO2 Brayton cycles and nuclear can maximally contribute to optimizing the water efficiency of carbon free power generation

  13. Exergoeconomic multi objective optimization and sensitivity analysis of a regenerative Brayton cycle

    International Nuclear Information System (INIS)

    Naserian, Mohammad Mahdi; Farahat, Said; Sarhaddi, Faramarz

    2016-01-01

    Highlights: • Finite time exergoeconomic multi objective optimization of a Brayton cycle. • Comparing the exergoeconomic and the ecological function optimization results. • Inserting the cost of fluid streams concept into finite-time thermodynamics. • Exergoeconomic sensitivity analysis of a regenerative Brayton cycle. • Suggesting the cycle performance curve drawing and utilization. - Abstract: In this study, the optimal performance of a regenerative Brayton cycle is sought through power maximization and then exergoeconomic optimization using finite-time thermodynamic concept and finite-size components. Optimizations are performed using genetic algorithm. In order to take into account the finite-time and finite-size concepts in current problem, a dimensionless mass-flow parameter is used deploying time variations. The decision variables for the optimum state (of multi objective exergoeconomic optimization) are compared to the maximum power state. One can see that the multi objective exergoeconomic optimization results in a better performance than that obtained with the maximum power state. The results demonstrate that system performance at optimum point of multi objective optimization yields 71% of the maximum power, but only with exergy destruction as 24% of the amount that is produced at the maximum power state and 67% lower total cost rate than that of the maximum power state. In order to assess the impact of the variation of the decision variables on the objective functions, sensitivity analysis is conducted. Finally, the cycle performance curve drawing according to exergoeconomic multi objective optimization results and its utilization, are suggested.

  14. Brayton-Cycle Power-Conversion Unit Tested With Ion Thruster

    Science.gov (United States)

    Hervol, David S.

    2005-01-01

    Nuclear electric propulsion has been identified as an enabling technology for future NASA space science missions, such as the Jupiter Icy Moons Orbiter (JIMO) now under study. An important element of the nuclear electric propulsion spacecraft is the power conversion system, which converts the reactor heat to electrical power for use by the ion propulsion system and other spacecraft loads. The electrical integration of the power converter and ion thruster represents a key technical challenge in making nuclear electric propulsion technology possible. This technical hurdle was addressed extensively on December 1, 2003, when a closed- Brayton-cycle power-conversion unit was tested with a gridded ion thruster at the NASA Glenn Research Center. The test demonstrated end-to-end power throughput and marked the first-ever coupling of a Brayton turbo alternator and a gridded ion thruster, both of which are candidates for use on JIMO-type missions. The testing was conducted at Glenn's Vacuum Facility 6, where the Brayton unit was installed in the 3-m-diameter vacuum test port and the ion thruster was installed in the 7.6-m-diameter main chamber.

  15. Experimental Results From a 2kW Brayton Power Conversion Unit

    Science.gov (United States)

    Hervol, David; Mason, Lee; Birchenough, Arthur

    2003-01-01

    This paper presents experimental test results from operation of a 2 kWe Brayton power conversion unit. The Brayton converter was developed for a solar dynamic power system flight experiment planned for the Mir Space Station in 1997. The flight experiment was cancelled, but the converter was tested at Glenn Research Center as part of the Solar Dynamic Ground Test Demonstration system which included a solar concentrator, heat receiver, and space radiator. In preparation for the current testing, the heat receiver was removed and replaced with an electrical resistance heater, simulating the thermal input of a steady-state nuclear source. The converter was operated over a full range of thermal input power levels and rotor speeds to generate an overall performance map. The converter unit will serve as the centerpiece of a Nuclear Electric Propulsion Testbed at Glenn. Future potential uses for the Testbed include high voltage electrical controller development, integrated electric thruster testing and advanced radiator demonstration testing to help guide high power Brayton technology development for Nuclear Electric Propulsion (NEP).

  16. A prospective, multicenter pilot study to investigate the feasibility and safety of a 1-year controlled exercise training after adjuvant chemotherapy in colorectal cancer patients.

    Science.gov (United States)

    Piringer, Gudrun; Fridrik, Michael; Fridrik, Alfred; Leiherer, Andreas; Zabernigg, August; Greil, Richard; Eisterer, Wolfgang; Tschmelitsch, Jörg; Lang, Alois; Frantal, Sophie; Burgstaller, Sonja; Gnant, Michael; Thaler, Josef

    2018-04-01

    Despite advances in adjuvant chemotherapy, 20-30% of patients in stages II-III colorectal cancer will eventually relapse. Observational studies showed a reduction in relapse rate, colon cancer-specific mortality, and overall mortality by physical activity. Results from prospective randomized interventional studies to confirm these observational data are lacking. The aims of this prospective single-arm multicenter pilot study are to evaluate feasibility and safety of exercise training after adjuvant chemotherapy in colorectal cancer patients. The training was performed three times per week for 1 year and was increased gradually in three phases until reaching 18 metabolic equivalent task hours per week. Overall, 30 patients were included. The planned training intensity could be achieved in all three phases. Patients experienced a performance increase of median 35.5 watt, a weight-loss of a median of 3.0 kg, and a reduction in body fat content of median 1.0% during this exercise training. The analysis showed early study termination due to non-compliance in 10/30 patients (33.3%), disease progression in 4 patients (13.3%), and serious adverse events in 2 patients (6.7%). About half of patients (46.7%) completed the pilot study as planned. Biomarker analysis from 20 patients showed a non-significant reduction in insulin-like growth factor 1 (IGF-1), insulin-like growth factor 2 (IGF-2) and insulin-like growth factor binding protein 3 (IGF-BP3) levels, significant increases in adiponectin and leptin levels, and a non-significant increase in C-peptide levels. Exercise training is feasible in patients with colorectal cancer after completion of adjuvant chemotherapy. The main problem encountered during the study was compliance. To improve compliance of exercise training, several measures were adapted for the upcoming prospective randomized ABCSG C08 Exercise II study.

  17. Feasibility and safety of early combined cognitive and physical therapy for critically ill medical and surgical patients: the Activity and Cognitive Therapy in ICU (ACT-ICU) trial

    Science.gov (United States)

    Brummel, N.E.; Girard, T.D.; Ely, E.W.; Pandharipande, P.P.; Morandi, A.; Hughes, C.G.; Graves, A.J.; Shintani, A.K.; Murphy, E.; Work, B.; Pun, B.T.; Boehm, L.; Gill, T.M.; Dittus, R.S.; Jackson, J.C.

    2013-01-01

    PURPOSE Cognitive impairment after critical illness is common and debilitating. We developed a cognitive therapy program for critically ill patients and assessed the feasibility and safety of administering combined cognitive and physical therapy early during a critical illness. METHODS We randomized 87 medical and surgical ICU patients with respiratory failure and/or shock in a 1:1:2 manner to three groups: usual care, early once-daily physical therapy, or early once-daily physical therapy plus a novel, progressive, twice-daily cognitive therapy protocol. Cognitive therapy included orientation, memory, attention, and problem solving exercises, and other activities. We assessed feasibility outcomes of the early cognitive plus physical therapy intervention. At 3-months, we also assessed cognitive, functional and health-related quality of life outcomes. Data are presented as median [interquartile range] or frequency (%). RESULTS Early cognitive therapy was a delivered to 41/43 (95%) of cognitive plus physical therapy patients on 100% [92–100%] of study days beginning 1.0 [1.0–1.0] day following enrollment. Physical therapy was received by 17/22 (77%) of usual care patients, by 21/22 (95%) of physical therapy only patients and 42/43 (98%) of cognitive plus physical therapy patients on 17% [10–26%], 67% [46–87%] and 75% [59–88%] of study days, respectively. Cognitive, functional and health-related quality of life outcomes did not differ between groups at 3-month follow-up. CONCLUSIONS This pilot study demonstrates that early rehabilitation can be extended beyond physical therapy to include cognitive therapy. Future work to determine optimal patient selection, intensity of treatment and benefits of cognitive therapy in the critically ill is needed. PMID:24257969

  18. Intracardiac echo-guided radiofrequency catheter ablation of atrial fibrillation in patients with atrial septal defect or patent foramen ovale repair: a feasibility, safety, and efficacy study.

    Science.gov (United States)

    Lakkireddy, Dhanunjaya; Rangisetty, Umamahesh; Prasad, Subramanya; Verma, Atul; Biria, Mazda; Berenbom, Loren; Pimentel, Rhea; Emert, Martin; Rosamond, Thomas; Fahmy, Tamer; Patel, Dimpi; Di Biase, Luigi; Schweikert, Robert; Burkhardt, David; Natale, Andrea

    2008-11-01

    Intracardiac Echo-Guided Radiofrequency Catheter. Patients with atrial septal defect (ASD) are at higher risk for atrial fibrillation (AF) even after repair. Transseptal access in these patients is perceived to be difficult. We describe the feasibility, safety, and efficacy of pulmonary vein antral isolation (PVAI) in these patients. We prospectively compared post-ASD/patent foramen ovale (PFO) repair patients (group I, n = 45) with age-gender-AF type matched controls (group II, n = 45). All the patients underwent PVAI through a double transseptal puncture with a roving circular mapping catheter technique guided by intracardiac echocardiography (ICE). The short-term (3 months) and long-term (12 month) failure rates were assessed. In group I, 23 (51%) had percutaneous closure devices and 22 (49%) had a surgical closure. There was no significant difference between group I and II in the baseline characteristics. Intracardiac echo-guided double transseptal access was obtained in 98% of patients in group I and in 100% of patients in group II. PVAI was performed in all patients, with right atrial flutter ablation in 7 patients in group I and in 4 patients in group II. Over a mean follow-up of 15 +/- 4 months, group I had higher short-term (18% vs 13%, P = 0.77) and long-term recurrence (24% vs 18%, P = 0.6) than group II. There was no significant difference in the perioperative complications between the two groups. Echocardiography at 3 months showed interatrial communication in 2 patients in group I and 1 patient in group II, which resolved at 12 months. Percutaneous AF ablation using double transseptal access is feasible, safe, and efficacious in patients with ASD and PFO repairs.

  19. Safety, acceptability, and feasibility of a single-visit approach to cervical-cancer prevention in rural Thailand: a demonstration project.

    Science.gov (United States)

    Gaffikin, L; Blumenthal, P D; Emerson, M; Limpaphayom, K

    2003-03-08

    To increase screening and treatment coverage, innovative approaches to cervical-cancer prevention are being investigated in rural Thailand. We assessed the value of a single-visit approach combining visual inspection of the cervix with acetic acid wash (VIA) and cryotherapy. 12 trained nurses provided services in mobile (village health centre-based) and static (hospital-based) teams in four districts of Roi-et Province, Thailand. Over 7 months, 5999 women were tested by VIA. If they tested positive, after counselling about the benefits, potential risks, and probable side-effects they were offered cryotherapy. Data measuring safety, acceptability, feasibility, and effort to implement the programme were gathered. The VIA test-positive rate was 13.3% (798/5999), and 98.5% (609/618) of those eligible accepted immediate treatment. Overall, 756 women received cryotherapy, 629 (83.2%) of whom returned for their first follow-up visit. No major complications were recorded, and 33 (4.4%) of those treated returned for a perceived problem. Only 17 (2.2%) of the treated women needed clinical management other than reassurance about side-effects. Both VIA and cryotherapy were highly acceptable to the patients (over 95% expressed satisfaction with their experience). At their 1-year visit, the squamocolumnar junction was visible to the nurses, and the VIA test-negative rate was 94.3%. A single-visit approach with VIA and cryotherapy seems to be safe, acceptable, and feasible in rural Thailand, and is a potentially efficient method of cervical-cancer prevention in such settings.

  20. A Novel Self-Expandable, Radioactive Airway Stent Loaded with 125I Seeds: A Feasibility and Safety Study in Healthy Beagle Dog.

    Science.gov (United States)

    Wang, Yong; Guo, Jin-He; Zhu, Guang-Yu; Zhu, Hai-Dong; Chen, Li; Lu, Jian; Wang, Chao; Teng, Gao-Jun

    2017-07-01

    Airway stent placement is an effective treatment for the immediate palliation of malignant airway obstruction. However, restenosis caused by tumor ingrowth and/or overgrowth after stenting is common. The purpose of this study was to investigate the feasibility and safety of a novel self-expandable stent loaded with 125 I seeds in healthy beagle dog. Under fluoroscopic guidance, forty-eight self-expandable airway stents loaded with 125 I seeds were perorally placed in the main trachea of 48 healthy beagle dogs, who were randomly divided into four groups (Group A: 0.3 mCi; Group B: 0.6 mCi; Group C: 0.9 mCi; Control group: 0 mCi). The estimated radiation dose was calculated using the isotropic point source approximation. Radiological follow-up examinations and histopathological examinations of stented tracheal segments and their adjacent organs and tissues were performed at 2, 4, 8, and 16 weeks following the stenting. All stents were successfully deployed in the targeted tracheal segment in the beagle dogs without procedure-related complications. Tracheal stenosis became severe gradually in all the four groups, which was not associated with the radioactivity of 125 I seeds (p > 0.05). The tracheal injury scores increased along with the higher dose of radioactive seeds which reached peak at 8 weeks and then turned back slightly at 16 weeks. The adjacent tissue did not show pathohistological changes under microscope, while mild and reversible ultrastructure changes were showed under electronic microscope. This study demonstrates that it is feasible and safe to insert this novel self-expandable airway stent loaded with 125 I seeds in healthy beagle dog.

  1. Feasibility and Safety of Intra-arterial Pericyte Progenitor Cell Delivery Following Mannitol-Induced Transient Blood-Brain Barrier Opening in a Canine Model.

    Science.gov (United States)

    Youn, Sung Won; Jung, Keun-Hwa; Chu, Kon; Lee, Jong-Young; Lee, Soon-Tae; Bahn, Jae-jun; Park, Dong-Kyu; Yu, Jung-Suk; Kim, So-Yun; Kim, Manho; Lee, Sang Kun; Han, Moon-Hee; Roh, Jae-Kyu

    2015-01-01

    Stem cell therapy is currently being studied with a view to rescuing various neurological diseases. Such studies require not only the discovery of potent candidate cells but also the development of methods that allow optimal delivery of those candidates to the brain tissues. Given that the blood-brain barrier (BBB) precludes cells from entering the brain, the present study was designed to test whether hyperosmolar mannitol securely opens the BBB and enhances intra-arterial cell delivery. A noninjured normal canine model in which the BBB was presumed to be closed was used to evaluate the feasibility and safety of the tested protocol. Autologous adipose tissue-derived pericytes with platelet-derived growth factor receptor β positivity were utilized. Cells were administered 5 min after mannitol pretreatment using one of following techniques: (1) bolus injection of a concentrated suspension, (2) continuous infusion of a diluted suspension, or (3) bolus injection of a concentrated suspension that had been shaken by repeated syringe pumping. Animals administered a concentrated cell suspension without mannitol pretreatment served as a control group. Vital signs, blood parameters, neurologic status, and major artery patency were kept stable throughout the experiment and the 1-month posttreatment period. Although ischemic lesions were noted on magnetic resonance imaging in several mongrel dogs with concentrated cell suspension, the injection technique using repeated syringe shaking could avert this complication. The cells were detected in both ipsilateral and contralateral cortices and were more frequent at the ipsilateral and frontal locations, whereas very few cells were observed anywhere in the brain when mannitol was not preinjected. These data suggest that intra-arterial cell infusion with mannitol pretreatment is a feasible and safe therapeutic approach in stable brain diseases such as chronic stroke.

  2. High-intensity interval training and hyperoxia during chemotherapy: A case report about the feasibility, safety and physical functioning in a colorectal cancer patient.

    Science.gov (United States)

    Freitag, Nils; Weber, Pia Deborah; Sanders, Tanja Christiane; Schulz, Holger; Bloch, Wilhelm; Schumann, Moritz

    2018-06-01

    We conducted a case study to examine the feasibility and safety of high-intensity interval training (HIIT) with increased inspired oxygen content in a colon cancer patient undergoing chemotherapy. A secondary purpose was to investigate the effects of such training regimen on physical functioning. A female patient (51 years; 49.1 kg; 1.65 m; tumor stage: pT3, pN2a (5/29), pM1a (HEP), L0, V0, R0) performed 8 sessions of HIIT (5 × 3 minutes at 90% of Wmax, separated by 2 minutes at 45% Wmax) with an increased inspired oxygen fraction of 30%. Patient safety, training adherence, cardiorespiratory fitness (peak oxygen uptake and maximal power output during an incremental cycle ergometer test), autonomous nervous function (i.e., heart rate variability during an orthostatic test) as well as questionnaire-assessed quality of life (EORTC QLQ-C30) were evaluated before and after the intervention.No adverse events were reported throughout the training intervention and a 3 months follow-up. While the patient attended all sessions, adherence to total training time was only 51% (102 of 200 minutes; mean training time per session 12:44 min:sec). VO2peak and Wmax increased by 13% (from 23.0 to 26.1 mL min kg) and 21% (from 83 to 100 W), respectively. Heart rate variability represented by the root mean squares of successive differences both in supine and upright positions were increased after the training by 143 and 100%, respectively. The EORTC QLQ-C30 score for physical functioning (7.5%) as well as the global health score (10.7%) improved, while social function decreased (17%). Our results show that a already short period of HIIT with concomitant hyperoxia was safe and feasible for a patient undergoing chemotherapy for colon cancer. Furthermore, the low overall training adherence of only 51% and an overall low training time per session (∼13 minutes) was sufficient to induce clinically meaningful improvements in physical functioning. However, this case also

  3. The feasibility and safety of high-intensity focused ultrasound combined with low-dose external beam radiotherapy as supplemental therapy for advanced prostate cancer following hormonal therapy.

    Science.gov (United States)

    Wu, Rui-Yi; Wang, Guo-Min; Xu, Lei; Zhang, Bo-Heng; Xu, Ye-Qing; Zeng, Zhao-Chong; Chen, Bing

    2011-05-01

    The aim of this study was to investigate the feasibility and safety of high-intensity focused ultrasound (HIFU) combined with (+) low-dose external beam radiotherapy (LRT) as supplemental therapy for advanced prostate cancer (PCa) following hormonal therapy (HT). Our definition of HIFU+LRT refers to treating primary tumour lesions with HIFU in place of reduced field boost irradiation to the prostate, while retaining four-field box irradiation to the pelvis in conventional-dose external beam radiotherapy (CRT). We performed a prospective, controlled and non-randomized study on 120 patients with advanced PCa after HT who received HIFU, CRT, HIFU+LRT and HT alone, respectively. CT/MR imaging showed the primary tumours and pelvic lymph node metastases visibly shrank or even disappeared after HIFU+LRT treatment. There were significant differences among four groups with regard to overall survival (OS) and disease-specific survival (DSS) curves (P = 0.018 and 0.015). Further comparison between each pair of groups suggested that the long-term DSS of the HIFU+LRT group was higher than those of the other three groups, but there was no significant difference between the HIFU+LRT group and the CRT group. Multivariable Cox's proportional hazard model showed that both HIFU+LRT and CRT were independently associated with DSS (P = 0.001 and 0.035) and had protective effects with regard to the risk of death. Compared with CRT, HIFU+LRT significantly decreased incidences of radiation-related late gastrointestinal (GI) and genitourinary (GU) toxicity grade ≥ II. In conclusion, long-term survival of patients with advanced PCa benefited from strengthening local control of primary tumour and regional lymph node metastases after HT. As an alternative to CRT, HIFU+LRT showed good efficacy and better safety.

  4. Feasibility and safety of on table extubation after corrective surgical repair of tetralogy of Fallot in a developing country: A case series

    Directory of Open Access Journals (Sweden)

    Mohammad Irfan Akhtar

    2015-01-01

    Full Text Available Fast-track extubation is an established safe practice in pediatric congenital heart disease (CHD surgical patients. On table extubation (OTE in acyanotic CHD surgical patients is well established with validated safety profile. This practice is not yet reported in tetralogy of Fallot (TOF cardiac surgical repair patients in developing countries. Evidence suggests that TOF total correction patients should be extubated early, as positive pressure ventilation has a negative impact on right ventricular function and the overall increase in post-TOF repair complications such as low cardiac output state and arrhythmias. The objective of the case series was to determine the safety and feasibility of OTE in elective TOF total correction cardiac surgical patients with an integrated team approach. To the best of our knowledge, this is the first reported case series. A total of 8 elective male and female TOF patients were included. Standard anesthetic, surgical and perfusion techniques were used in these procedures. All patients were extubated in the operating room safely without any complications with the exception of one patient who continued to bleed for 3 h of postextubation at 2-3 ml/kg/h which was managed with transfusion of fresh frozen plasma at 15 mL/kg, packed red blood cells 10 mL/kg and bolus of transamine at 20 mg/kg. Apart from better surgical and bypass techniques, the most important factor leading to successful OTE was an excellent analgesia. On the basis of the case series, it is suggested to extubate selected TOF cardiac surgery repair patients on table safely with integrated multidisciplinary approach.

  5. Feasibility, safety, and economic implications of whey-recovered water in cleaning-in-place systems: A case study on water conservation for the dairy industry.

    Science.gov (United States)

    Meneses, Yulie E; Flores, Rolando A

    2016-05-01

    Water scarcity is threatening food security and business growth in the United States. In the dairy sector, most of the water is used in cleaning applications; therefore, any attempt to support water conservation in these processes will have a considerable effect on the water footprint of dairy products. This study demonstrates the viability for recovering good quality water from whey, a highly pollutant cheese-making by-product, to be reused in cleaning-in-place systems. The results obtained in this study indicate that by using a combined ultrafiltration and reverse osmosis system, 47% of water can be recovered. This system generates protein and lactose concentrates, by-products that once spray-dried fulfill commercial standards for protein and lactose powders. The physicochemical and microbiological quality of the recovered permeate was also analyzed, suggesting suitable properties to be reused in the cleaning-in-place system without affecting the quality and safety of the product manufactured on the cleaned equipment. A cost analysis was conducted for 3 cheese manufacturing levels, considering an annual production of 1, 20, and 225 million liters of whey. Results indicate the feasibility of this intervention in the dairy industry, generating revenues of $0.18, $3.05, and $33.4 million per year, respectively. The findings provide scientific evidence to promote the safety of reuse of reconditioned water in food processing plants, contributing to building a culture of water conservation and sustainable production throughout the food supply chain. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  6. Intraarterial reteplase and intravenous abciximab for treatment of acute ischemic stroke. A preliminary feasibility and safety study in a non-human primate model

    International Nuclear Information System (INIS)

    Qureshi, Adnan I.; Suri, M. Fareed K.; Ali, Zulfiqar; Ringer, Andrew J.; Boulos, Alan S.; Guterman, Lee R.; Hopkins, L. Nelson; Nakada, Marian T.; Alberico, Ronald A.; Martin, Lisa B.E.

    2005-01-01

    We performed a preliminary feasibility and safety study using intravenous (IV) administration of a platelet glycoprotein IIb/IIIa inhibitor (abciximab) in conjunction with intraarterial (IA) administration of a thrombolytic agent (reteplase) in a primate model of intracranial thrombosis. We introduced thrombus through superselective catheterization of the intracranial segment of the internal carotid artery in 16 primates. The animals were randomly assigned to receive IA reteplase and IV abciximab (n =4), IA reteplase and IV placebo (n =4), IA placebo and IV abciximab (n =4) or IA and IV placebo (n =4). Recanalization was assessed by serial angiography during the 6-h period after initiation of treatment. Postmortem magnetic resonance (MR) imaging was performed to determine the presence of cerebral infarction or intracranial hemorrhage. Partial or complete recanalization at 6 h after initiation of treatment (decrease of two or more points in pre-treatment angiographic occlusion grade) was observed in two animals treated with IA reteplase and IV abciximab, three animals treated with IA reteplase alone and one animal treated with IV abciximab alone. No improvement in perfusion was observed in animals that received IV and IA placebo. Cerebral infarction was demonstrated on postmortem MR imaging in three animals that received IA and IV placebo and in one animal each from the groups that received IA reteplase and IV abciximab or IV abciximab alone. One animal that received IV abciximab alone had a small intracerebral hemorrhage on MR imaging. (orig.)

  7. Neuroendoscopic Resection of Intraventricular Tumors and Cysts through a Working Channel with a Variable Aspiration Tissue Resector: A Feasibility and Safety Study

    Directory of Open Access Journals (Sweden)

    Edjah Kweku-Ebura Nduom

    2013-01-01

    Full Text Available Pure neuroendoscopic resection of intraventricular lesions through a burr hole is limited by the instrumentation that can be used with a working channel endoscope. We describe a safety and feasibility study of a variable aspiration tissue resector, for the resection of a variety of intraventricular lesions. Our initial experience using the variable aspiration tissue resector involved 16 patients with a variety of intraventricular tumors or cysts. Nine patients (56% presented with obstructive hydrocephalus. Patient ages ranged from 20 to 88 years (mean 44.2. All patients were operated on through a frontal burr hole, using a working channel endoscope. A total of 4 tumors were resected in a gross total fashion and the remaining intraventricular lesions were subtotally resected. Fifteen of 16 patients had relief of their preoperative symptoms. The 9 patients who presented with obstructive hydrocephalus had restoration of cerebrospinal fluid flow though one required a ventriculoperitoneal shunt. Three patients required repeat endoscopic resections. Use of a variable aspiration tissue resector provides the ability to resect a variety of intraventricular lesions in a safe, controlled manner through a working channel endoscope. Larger intraventricular tumors continue to pose a challenge for complete removal of intraventricular lesions.

  8. Report to the Congress on the need for, and the feasibility of, establishing a security agency within the Office of Nuclear Material Safety and Safeguards

    International Nuclear Information System (INIS)

    1976-08-01

    In response to the Congressional mandate Section 204(b)-(2) (C) of the Energy Reorganization Act of 1974, the Director of the Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory Commission (NRC) has assessed the need for and the feasibility of establishing a security agency within that office for the performance of safeguards functions. The study assessed guard force effectiveness, and addressed public policy, administrative and legal issues. The study concluded that creation of a special security force within NRC would not result in a higher degree of guard force effectiveness than can be achieved through the use of private guards who have been properly trained and certified. Disparate gun laws in various states, it concluded, restrict arms possessed by both private and federal guards and private and federal transportation guards would require legislation authorizing them to bear the necessary weapons to protect nuclear material in transit. The role of reaction forces was also addressed and it was concluded that primary reliance at fixed sites should be placed on onsite protection systems; for material in transit, on invulnerability of vehicles and containers and on guard forces accompanying shipments

  9. Safety and feasibility of thallium-201 myocardial SPECT with intravenous infusion of disodium adenosine triphosphate (ATP) in the diagnosis of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Pai, Moon Sun; Park, Chan H.; Yoon, Seok Nam; Kim, Won; Kim, Han Soo [College of Medicine, Ajou Univ., Suwon (Korea, Republic of)

    1998-08-01

    ATP (adenosine triphosphate) is a potent coronary vasodilator with a rapid onset of action and a very short half-life. Myocardial perfusion scintigraphy with intravenous ATP has not yet bee sufficiently proven in the diagnosis, follow-up, and risk stratification of coronary artery disease. The purpose of this study was to evaluate the safety, feasibility and diagnostic accuracy of pharmacologic stress thallium-102 myocardial SPECT using an intravenous ATP infusion in patients with suspected coronary artery disease. Thallium-201 myocardial SPECT in 319 patients with suspected coronary artery disease were performed after the infusion of ATP (0.08 mg/min for 6 min). The adverse effects were carefully monitored. Coronary angiography was also performed within 3 weeks. Although 76.5% of he patients had some adverse effects, they were transient, mild, and well tolerated. In all patients, the ATP infusion protocol was completed and only 2 patients required aminophylline. The adverse effects were dyspnea in 63%, headache in 31%, flushing in 21%, chest pain in 14% and abdominal discomfort in 5% of the patients. The sensitivity and specificity were 80% and 90% respectively. Thallium-201 myocardial SPECT after 6 min-infusion of ATP at a rate of 0.08 mg/kg/min is safe and has a diagnostic value in detecting coronary artery disease.

  10. Safety and feasibility of thallium-201 myocardial SPECT with intravenous infusion of disodium adenosine triphosphate (ATP) in the diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Pai, Moon Sun; Park, Chan H.; Yoon, Seok Nam; Kim, Won; Kim, Han Soo

    1998-01-01

    ATP (adenosine triphosphate) is a potent coronary vasodilator with a rapid onset of action and a very short half-life. Myocardial perfusion scintigraphy with intravenous ATP has not yet bee sufficiently proven in the diagnosis, follow-up, and risk stratification of coronary artery disease. The purpose of this study was to evaluate the safety, feasibility and diagnostic accuracy of pharmacologic stress thallium-102 myocardial SPECT using an intravenous ATP infusion in patients with suspected coronary artery disease. Thallium-201 myocardial SPECT in 319 patients with suspected coronary artery disease were performed after the infusion of ATP (0.08 mg/min for 6 min). The adverse effects were carefully monitored. Coronary angiography was also performed within 3 weeks. Although 76.5% of he patients had some adverse effects, they were transient, mild, and well tolerated. In all patients, the ATP infusion protocol was completed and only 2 patients required aminophylline. The adverse effects were dyspnea in 63%, headache in 31%, flushing in 21%, chest pain in 14% and abdominal discomfort in 5% of the patients. The sensitivity and specificity were 80% and 90% respectively. Thallium-201 myocardial SPECT after 6 min-infusion of ATP at a rate of 0.08 mg/kg/min is safe and has a diagnostic value in detecting coronary artery disease

  11. Coiled Tube Gas Heaters For Nuclear Gas-Brayton Power Conversion

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, Per F.

    2018-03-31

    This project developed an alternative design for heat exchangers for application to heating supercritical carbon dioxide (S-CO2) or air for power conversion. We have identified an annular coiled tube bundle configuration–where hot sodium enters tubes from multiple vertical inlet manifold pipes, flows in a spiral pattern radially inward and downward, and then exits into an equal number of vertical outlet manifold pipes–as a potentially attractive option. The S-CO2 gas or air flows radially outward through the tube bundle. Coiled tube gas heaters (CTGHs) are expected to have excellent thermal shock, long-term thermal creep, in-service inspection, and reparability characteristics, compared to alternative options. CTGHs have significant commonality with modern nuclear steam generators. Extensive experience exists with the design, manufacture, operation, in-service inspection and maintenance of nuclear steam generators. The U.S. Nuclear Regulatory Commission also has extensive experience with regulatory guidance documented in NUREG 0800. CTGHs leverage this experience and manufacturing capability. The most important difference between steam generators and gas-Brayton cycles such as the S-CO2 cycle is that the heat exchangers must operate with counter flow with high effectiveness to minimize the pinch-point temperature difference between the hot liquid coolant and the heated gas. S-CO2-cycle gas heaters also operate at sufficiently elevated temperatures that time dependent creep is important and allowable stresses are relatively low. Designing heat exchangers to operate in this regime requires configurations that minimize stresses and stress concentrations. The cylindrical tubes and cylindrical manifold pipes used in CTGHs are particularly effective geometries. The first major goal of this research project was to develop and experimentally validate a detailed, 3-D multi-phase (gas-solid-liquid) heat transport model for

  12. Reactor/Brayton power systems for nuclear electric spacecraft

    Science.gov (United States)

    Layton, J. P.

    1980-01-01

    Studies are currently underway to assess the technological feasibility of a nuclear-reactor-powered spacecraft propelled by electric thrusters. This vehicle would be capable of performing detailed exploration of the outer planets of the solar system during the remainder of this century. The purpose of this study was to provide comparative information on a closed cycle gas turbine power conversion system. The results have shown that the performance is very competitive and that a 400 kWe space power system is dimensionally compatible with a single Space Shuttle launch. Performance parameters of system mass and radiator area were determined for systems from 100 to 1000 kWe. A 400 kWe reference system received primary attention. The components of this system were defined and a conceptual layout was developed with encouraging results. The preliminary mass determination for the complete power system was very close to the desired goal of 20 kg/kWe. Use of more advanced technology (higher turbine inlet temperature) will substantially improve system performance characteristics.

  13. Features of supercritical carbon dioxide Brayton cycle coupled with reactor

    International Nuclear Information System (INIS)

    Duan Chengjie; Wang Jie; Yang Xiaoyong

    2010-01-01

    In order to obtain acceptable cycle efficiency, current helium gas turbine power cycle technology needs high cycle temperature which means that the cycle needs high core-out temperature. The technology has high requirements on reactor structure and fuel elements materials, and also on turbine manufacture. While utilizing CO 2 as cycle working fluid, it can guarantee to lower the cycle temperature and turbo machine Janume but achieve the same cycle efficiency, so as to enhance the safety and economy of reactor. According to the laws of thermodynamics, a calculation model of supercritical CO 2 power cycle was established to analyze the feature, and the decisive parameters of the cycle and also investigate the effect of each parameter on the cycle efficiency in detail were obtained. The results show that supercritical CO 2 power cycle can achieve quite satisfied efficiency at a lower cycle highest temperature than helium cycle, and CO 2 is a promising working fluid. (authors)

  14. An observational feasibility study to assess the safety and effectiveness of intranasal fentanyl for radiofrequency ablations of the lumbar facet joints

    Directory of Open Access Journals (Sweden)

    Bartoszek MW

    2017-02-01

    Full Text Available Michael W Bartoszek,1 Amy McCoart,2 Kyung-soo Jason Hong,3 Chelsey Haley,2 Krista Beth Highland,4 Anthony R Plunkett1 1Department of Anesthesiology, Womack Army Medical Center, Fort Bragg, NC, 2Clinical Investigations, Defense and Veterans Center for Integrative Pain Management, Henry M. Jackson Foundation, Womack Army Medical Center, Fort Bragg, NC, 3Research Department, The Center for Clinical Research, Sceptor Pain Foundation, Winston Salem, NC, 4Defense and Veterans Center for Integrative Pain Management, Henry M. Jackson Foundation, Uniformed Services University, Bethesda, MD, USA Purpose: The purpose of the present observational, feasibility study is to assess the preliminary safety and effectiveness of intranasal fentanyl for lumbar facet radiofrequency ablation procedures.Patients and methods: This cohort observational study included 23 adult patients. Systolic and diastolic blood pressures, heart rate, oxygen saturation percent, Pasero Opioid-Induced Sedation Scale score, and the Defense and Veterans Pain Rating Scale pain score were assessed prior to the procedure and intranasal fentanyl (100 μg administration and every 15 minutes after administration, up to 60 minutes post administration. Follow-up of patient satisfaction with pain control and treatment was assessed 24 hours after discharge. The primary outcome was safety as evidenced by adverse events. Secondary outcomes included the above-mentioned vital signs and pain ratings.Results: No adverse events occurred in the present study and all participants maintained an acceptable level of awareness throughout the assessment period. One-way repeated measures analyses of covariance tests with Bonferroni-adjusted means indicated that oxygen saturation, blood pressure, and heart rate changed from baseline, whereas pain scores were lower at post-administration levels compared with baseline. Finally, the majority of participants reported being satisfied with pain control and treatment

  15. Numerical Comparison of NASA's Dual Brayton Power Generation System Performance Using CO2 or N2 as the Working Fluid

    Science.gov (United States)

    Ownens, Albert K.; Lavelle, Thomas M.; Hervol, David S.

    2010-01-01

    A Dual Brayton Power Conversion System (DBPCS) has been tested at the NASA Glenn Research Center using Nitrogen (N2) as the working fluid. This system uses two closed Brayton cycle systems that share a common heat source and working fluid but are otherwise independent. This system has been modeled using the Numerical Propulsion System Simulation (NPSS) environment. This paper presents the results of a numerical study that investigated system performance changes resulting when the working fluid is changed from gaseous (N2) to gaseous carbon dioxide (CO2).

  16. Motor starting a Brayton cycle power conversion system using a static inverter

    Science.gov (United States)

    Curreri, J. S.; Edkin, R. A.; Kruchowy, R.

    1973-01-01

    The power conversion module of a 2- to 15-kWe Brayton engine was motor started using a three-phase, 400-hertz static inverter as the power source. Motor-static tests were conducted for initial gas loop pressures of 10, 14, and 17 N/sq cm (15, 20, and 25 psia) over a range of initial turbine inlet temperatures from 366 to 550 K (200 to 530 F). The data are presented to show the effects of temperature and pressure on the motor-start characteristics of the rotating unit. Electrical characteristics during motoring are also discussed.

  17. Advanced Rankine and Brayton cycle power systems: Materials needs and opportunities

    Science.gov (United States)

    Grisaffe, S. J.; Guentert, D. C.

    1974-01-01

    Conceptual advanced potassium Rankine and closed Brayton power conversion cycles offer the potential for improved efficiency over steam systems through higher operating temperatures. However, for utility service of at least 100,000 hours, materials technology advances will be needed for such high temperature systems. Improved alloys and surface protection must be developed and demonstrated to resist coal combustion gases as well as potassium corrosion or helium surface degradation at high temperatures. Extensions in fabrication technology are necessary to produce large components of high temperature alloys. Long time property data must be obtained under environments of interest to assure high component reliability.

  18. Advanced Rankine and Brayton cycle power systems - Materials needs and opportunities

    Science.gov (United States)

    Grisaffe, S. J.; Guentert, D. C.

    1974-01-01

    Conceptual advanced potassium Rankine and closed Brayton power conversion cycles offer the potential for improved efficiency over steam systems through higher operating temperatures. However, for utility service of at least 100,000 hours, materials technology advances will be needed for such high temperature systems. Improved alloys and surface protection must be developed and demonstrated to resist coal combustion gases as well as potassium corrosion or helium surface degradation at high temperatures. Extensions in fabrication technology are necessary to produce large components of high temperature alloys. Long-time property data must be obtained under environments of interest to assure high component reliability.

  19. The maximum power condition of the brayton cycle with heat exchange processes

    International Nuclear Information System (INIS)

    Jung, Pyung Suk; Cha, Jin Girl; Ro, Sung Tack

    1985-01-01

    The ideal brayton cycle has been analyzed with the heat exchange processes between the working fluid and the heat source and the sink while their heat capacity rates are constant. The power of the cycle can be expressed in terms of a temperature of the cycle and the heat capacity rate of the working fluid. There exists an optimum power condition where the heat capacity rate of the working fluid has a value between those of the heat source and the heat sink, and the cycle efficiency is determined by the inlet temperatures of the heat source and the sink. (Author)

  20. Computer simulation of transitional process to the final stable Brayton cycle in magnetic refrigeration

    International Nuclear Information System (INIS)

    Numasawa, T.; Hashimoto, T.

    1981-01-01

    The final working cycle in the magnetic refrigeration largely depends on the heat transfer coefficient β in the system, the parameter γ of the heat inflow from the outer system to this cycle and the period tau of the cycle. Therefore, so as to make clear this dependence, the time variation of the Brayton cycle with β, γ and tau has been investigated. In the present paper the transitional process of this cycle and the dependence of the final cooling temperature of the heat load on β, γ and tau have all been shown. (orig.)

  1. Clinical safety of an MRI conditional implantable cardioverter defibrillator system: A prospective Monocenter ICD-Magnetic resonance Imaging feasibility study (MIMI).

    Science.gov (United States)

    Kypta, Alexander; Blessberger, Hermann; Hoenig, Simon; Saleh, Karim; Lambert, Thomas; Kammler, Juergen; Fellner, Franz; Lichtenauer, Michael; Steinwender, Clemens

    2016-03-01

    The aim of this study was to evaluate the safety and efficacy of the Lumax 740(®) Implantable Cardioverter Defibrillator (ICD) system in patients undergoing a defined 1.5 Tesla (T) MRI. Between November 2013 and April 2014, eighteen patients (age range, 41-78 years; mean age, 64 years) implanted with a Lumax 740(®) ICD system for at least 6 weeks before an MRI were enrolled into this single-center feasibility study. The local ethics committee approved the study before patients gave written informed consent. Patients underwent defined MRI 1.5T of the brain and lower lumbar spine with three safety follow-up evaluations obtained during the 3-month study period. Data were analyzed descriptively. Study endpoints were the absence of either MRI and pacing system related serious adverse device effects (SADE), or of a ventricular pacing threshold increase >0.5V, or of an R-wave amplitude attenuation battery status. Sixteen patients completed the MRI and the follow-up period. As no SADE occurred, the SADE free rate was 100%. Freedom from ventricular pacing threshold increase was 100% (16/16; 95%CI: 82.9%; 100.0%). There were no significant differences between baseline and follow-up measurements of sensing amplitudes (-0.58 ± 2.07 mV, P = 0.239, -0.41 ± 1.04 mV, P = 0.133, and -0.25 ± 1.36 mV, P = 0.724, for immediately after, 1 month and 3 months after MRI scan, respectively) and pacing thresholds (-0.047 ± 0.18 V, P = 0.317, -0.019 ± 0.11 V, P = 0.490, and 0.075 ± 0.19 V, P = 0.070, for immediately after, 1 month and 3 months after MRI scan, respectively). Lead impedances after the MRI scan were significantly lower as compared with baseline values (-22.8 ± 21.69 Ω, P = 0.001, -21.62 ± 39.71 Ω, P = 0.040, and -33.68 ± 57.73 Ω, P = 0.018, for immediately after, 1 month and 3 months after MRI scan, respectively). MRI scans in patients with MRI conditional ICD system (Lumax 740(

  2. Feasibility and safety of low-flow extracorporeal carbon dioxide removal to facilitate ultra-protective ventilation in patients with moderate acute respiratory distress sindrome.

    Science.gov (United States)

    Fanelli, Vito; Ranieri, Marco V; Mancebo, Jordi; Moerer, Onnen; Quintel, Michael; Morley, Scott; Moran, Indalecio; Parrilla, Francisco; Costamagna, Andrea; Gaudiosi, Marco; Combes, Alain

    2016-02-10

    Mechanical ventilation with a tidal volume (VT) of 6 mL/kg/predicted body weight (PBW), to maintain plateau pressure (Pplat) lower than 30 cmH2O, does not completely avoid the risk of ventilator induced lung injury (VILI). The aim of this study was to evaluate safety and feasibility of a ventilation strategy consisting of very low VT combined with extracorporeal carbon dioxide removal (ECCO2R). In fifteen patients with moderate ARDS, VT was reduced from baseline to 4 mL/kg PBW while PEEP was increased to target a plateau pressure--(Pplat) between 23 and 25 cmH2O. Low-flow ECCO2R was initiated when respiratory acidosis developed (pH 60 mmHg). Ventilation parameters (VT, respiratory rate, PEEP), respiratory compliance (CRS), driving pressure (DeltaP = VT/CRS), arterial blood gases, and ECCO2R system operational characteristics were collected during the period of ultra-protective ventilation. Patients were weaned from ECCO2R when PaO2/FiO2 was higher than 200 and could tolerate conventional ventilation settings. Complications, mortality at day 28, need for prone positioning and extracorporeal membrane oxygenation, and data on weaning from both MV and ECCO2R were also collected. During the 2 h run in phase, VT reduction from baseline (6.2 mL/kg PBW) to approximately 4 mL/kg PBW caused respiratory acidosis (pH protective mechanical ventilation strategy in patients with moderate ARDS.

  3. Retrograde Wiring of Collateral Channels of the Heart in Chronic Total Occlusions: A Systematic Review and Meta-Analysis of Safety, Feasibility, and Incremental Value in Achieving Revascularization.

    Science.gov (United States)

    Khand, Aleem; Patel, Bilal; Palmer, Nicholas; Jones, Julia; Andron, Mohammed; Perry, Raph; Mehrotra, Sanjay; Mitsudo, Kazuaki

    2015-11-01

    To conduct a systematic review and meta-analysis on retrograde wiring in chronic total occlusions (CTOs) with focus on its safety and feasibility. We searched publications from 1990 to December 2013 in PubMed, Ovid, EMBASE, and the Cochrane database inserting a number of terms relating to the collateral circulation of the heart in CTOs. A total of 18 case series (n range17-462) with a total of 2280 CTO revascularization attempts fulfilled criteria for a study of retrograde wiring of collateral channels in CTOs. There were no randomized studies comparing a primary antegrade with a primary retrograde approach. Procedural CTO revascularization rates ranged from 67% to 90.6% with a large proportion having previously failed an "antegrade" approach. The septal perforator collaterals and epicardial channels were used in 73.2% (n = 1670) and 21.7% (n = 495) of cases. Although collateral/coronary perforation was not infrequent (n = 90, 5%), serious acute complications were uncommon; in the combined population 18 cases of cardiac tamponade (0.8%) and 3 deaths (0.1%). Septal perforating wiring (79.3%) was significantly more likely to be successful compared to epicardial coronary artery wiring (72.5%) when chosen by the operator as a route of retrograde access to the CTO body (relative risk 1.11 [95% confidence interval: 1.02-1.20; P = .013]). Successful retrograde wiring of collateral channels in selected patients undertaken by "CTO dedicated" operators can significantly enhance the chances of revascularization of complex CTOs with a low risk of acute serious complications. Septal perforator channels are significantly more likely to be successfully retrogradely wired compared to epicardial vessels when either is selected, by reference to their anatomical suitability by the operator, as a route of access. © The Author(s) 2015.

  4. SAFETY

    CERN Multimedia

    M. Plagge, C. Schaefer and N. Dupont

    2013-01-01

    Fire Safety – Essential for a particle detector The CMS detector is a marvel of high technology, one of the most precise particle measurement devices we have built until now. Of course it has to be protected from external and internal incidents like the ones that can occur from fires. Due to the fire load, the permanent availability of oxygen and the presence of various ignition sources mostly based on electricity this has to be addressed. Starting from the beam pipe towards the magnet coil, the detector is protected by flooding it with pure gaseous nitrogen during operation. The outer shell of CMS, namely the yoke and the muon chambers are then covered by an emergency inertion system also based on nitrogen. To ensure maximum fire safety, all materials used comply with the CERN regulations IS 23 and IS 41 with only a few exceptions. Every piece of the 30-tonne polyethylene shielding is high-density material, borated, boxed within steel and coated with intumescent (a paint that creates a thick co...

  5. SAFETY

    CERN Multimedia

    C. Schaefer and N. Dupont

    2013-01-01

      “Safety is the highest priority”: this statement from CERN is endorsed by the CMS management. An interpretation of this statement may bring you to the conclusion that you should stop working in order to avoid risks. If the safety is the priority, work is not! This would be a misunderstanding and misinterpretation. One should understand that “working safely” or “operating safely” is the priority at CERN. CERN personnel are exposed to different hazards on many levels on a daily basis. However, risk analyses and assessments are done in order to limit the number and the gravity of accidents. For example, this process takes place each time you cross the road. The hazard is the moving vehicle, the stake is you and the risk might be the risk of collision between both. The same principle has to be applied during our daily work. In particular, keeping in mind the general principles of prevention defined in the late 1980s. These principles wer...

  6. Feasibility and safety of treating non-unions in tibia, femur and humerus with autologous, expanded, bone marrow-derived mesenchymal stromal cells associated with biphasic calcium phosphate biomaterials in a multicentric, non-comparative trial.

    Science.gov (United States)

    Gómez-Barrena, Enrique; Rosset, Philippe; Gebhard, Florian; Hernigou, Philippe; Baldini, Nicola; Rouard, Helène; Sensebé, Luc; Gonzalo-Daganzo, Rosa M; Giordano, Rosaria; Padilla-Eguiluz, Norma; García-Rey, Eduardo; Cordero-Ampuero, José; Rubio-Suárez, Juan Carlos; Stanovici, Julien; Ehrnthaller, Christian; Huber-Lang, Markus; Flouzat-Lachaniette, Charles Henri; Chevallier, Nathalie; Donati, Davide Maria; Ciapetti, Gabriela; Fleury, Sandrine; Fernandez, Manuel-Nicolás; Cabrera, José-Rafael; Avendaño-Solá, Cristina; Montemurro, Tiziana; Panaitescu, Carmen; Veronesi, Elena; Rojewski, Markus Thomas; Lotfi, Ramin; Dominici, Massimo; Schrezenmeier, Hubert; Layrolle, Pierre

    2018-03-19

    ORTHO-1 is a European, multicentric, first in human clinical trial to prove safety and feasibility after surgical implantation of commercially available biphasic calcium phosphate bioceramic granules associated during surgery with autologous mesenchymal stromal cells expanded from bone marrow (BM-hMSC) under good manufacturing practices, in patients with long bone pseudarthrosis. Twenty-eight patients with femur, tibia or humerus diaphyseal or metaphyso-diaphyseal non-unions were recruited and surgically treated in France, Germany, Italy and Spain with 100 or 200 million BM-hMSC/mL associated with 5-10 cc of bioceramic granules. Patients were followed up during one year. The investigational advanced therapy medicinal product (ATMP) was expanded under the same protocol in all four countries, and approved by each National Competent Authority. With safety as primary end-point, no severe adverse event was reported as related to the BM-hMSC. With feasibility as secondary end-point, the participating production centres manufactured the BM-hMSC as planned. The ATMP combined to the bioceramic was surgically delivered to the non-unions, and 26/28 treated patients were found radiologically healed at one year (3 out of 4 cortices with bone bridging). Safety and feasibility were clinically proven for surgical implantation of expanded autologous BM-hMSC with bioceramic. EU-FP7-HEALTH-2009, REBORNE Project (GA: 241876). Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. Safety

    International Nuclear Information System (INIS)

    Jones, P.M.S.

    1987-01-01

    Aspects of fission reactors are considered - control, heat removal and containment. Brief descriptions of the reactor accidents at the SL-1 reactor (1961), Windscale (1957), Browns Ferry (1975), Three Mile Island (1979) and Chernobyl (1986) are given. The idea of inherently safe reactor designs is discussed. Safety assessment is considered under the headings of preliminary hazard analysis, failure mode analysis, event trees, fault trees, common mode failure and probabalistic risk assessments. These latter can result in a series of risk distributions linked to specific groups of fault sequences and specific consequences. A frequency-consequence diagram is shown. Fatal accident incidence rates in different countries including the United Kingdom for various industries are quoted. The incidence of fatal cancers from occupational exposure to chemicals is tabulated. Human factors and the acceptability of risk are considered. (U.K.)

  8. A four-year investigation of Brayton cycle systems for future french space power applications

    International Nuclear Information System (INIS)

    Tilliette, Z.P.; Proust, E.; Carre, F.

    1988-01-01

    Within the framework of a joint program initiated in 1983 by the two French Government Agencies C.N.E.S. (Centre National d'Etudes Spatiales) and C.E.A. (Commissariat a l'Energie Atomique), in order to study space nuclear power systems for future ARIANE 5 applications, extensive investigations have dealt with the Brayton cycle which has been selected as the energy conversion system. Several aspects can be mentioned in this field: the matching of the power system to the available radiator dimensions up to 200 kWe, the direct or indirect waste heat transfer to the radiator, the use of a recuperator, the recent work on moderate (25 kWe) power levels, the simulation studies related to various operating conditions and the general system optimization. A limited experimental program is starting on some crucial technology areas including a first contract to the industry concerning the turbogenerator. Particular attention is being paid to the significance of the adoption of a Brayton cycle for space applications involving a nuclear heat source which can be either a liquid metal-cooled or a gas-cooled reactor. As far as a gas-cooled reactor, direct cycle system is concerned, the relevance to the reactor technology and the concept for moderator thermal conditioning, is particularly addressed

  9. Thermoeconomic Analysis and Optimization of a New Combined Supercritical Carbon Dioxide Recompression Brayton/Kalina Cycle

    Directory of Open Access Journals (Sweden)

    S. Mohammad S. Mahmoudi

    2016-10-01

    Full Text Available A new combined supercritical CO2 recompression Brayton/Kalina cycle (SCRB/KC is proposed. In the proposed system, waste heat from a supercritical CO2 recompression Brayton cycle (SCRBC is recovered by a Kalina cycle (KC to generate additional electrical power. The performances of the two cycles are simulated and compared using mass, energy and exergy balances of the overall systems and their components. Using the SPECO (Specific Exergy Costing approach and employing selected cost balance equations for the components of each system, the total product unit costs of the cycles are obtained. Parametric studies are performed to investigate the effects on the SCRB/KC and SCRBC thermodynamic and thermoeconomic performances of key decision parameters. In addition, considering the exergy efficiency and total product unit cost as criteria, optimization is performed for the SCRBC and SCRB/KC using Engineering Equation Solver software. The results indicate that the maximum exergy efficiency of the SCRB/KC is higher than that of the SCRBC by up to 10%, and that the minimum total product unit cost of the SCRB/KC is lower than that of the SCRBC by up to 4.9%.

  10. Counter flow induced draft cooling tower option for supercritical carbon dioxide Brayton cycle

    Energy Technology Data Exchange (ETDEWEB)

    Pidaparti, Sandeep R., E-mail: sandeep.pidaparti@gmail.com [Georgia Institute of Technology, George W. Woodruff School of Mechanical Engineering, Atlanta, GA 30332 (United States); Moisseytsev, Anton; Sienicki, James J. [Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States); Ranjan, Devesh, E-mail: devesh.ranjan@me.gatech.edu [Georgia Institute of Technology, George W. Woodruff School of Mechanical Engineering, Atlanta, GA 30332 (United States)

    2015-12-15

    Highlights: • A code was developed to investigate the various aspects of using cooling tower for S-CO{sub 2} Brayton cycles. • Cooling tower option to reject heat is quantitatively compared to the direct water cooling and dry air cooling options. • Optimum water conditions resulting in minimal plant capital cost per unit power consumption are calculated. - Abstract: A simplified qualitative analysis was performed to investigate the possibility of using counter flow induced draft cooling tower option to reject heat from the supercritical carbon dioxide Brayton cycle for advanced fast reactor (AFR)-100 and advanced burner reactor (ABR)-1000 plants. A code was developed to estimate the tower dimensions, power and water consumption, and to perform economic analysis. The code developed was verified against a vendor provided quotation and is used to understand the effect of ambient air and water conditions on the design of cooling tower. The calculations indicated that there exists optimum water conditions for given ambient air conditions which will result in minimum power consumption, thereby increasing the cycle efficiency. A cost-based optimization technique is used to estimate the optimum water conditions which will improve the overall plant economics. A comparison of different cooling options for the S-CO{sub 2} cycle indicated that the cooling tower option is a much more practical and economical option compared to the dry air cooling or direct water cooling options.

  11. Heat exchanger design for hot air ericsson-brayton piston engine

    Directory of Open Access Journals (Sweden)

    Ďurčanský P.

    2014-03-01

    Full Text Available One of the solutions without negative consequences for the increasing energy consumption in the world may be use of alternative energy sources in micro-cogeneration. Currently it is looking for different solutions and there are many possible ways. Cogeneration is known for long time and is widely used. But the installations are often large and the installed output is more suitable for cities or industry companies. When we will speak about decentralization, the small machines have to be used. The article deals with the principle of hot-air engines, their use in combined heat and electricity production from biomass and with heat exchangers as primary energy transforming element. In the article is hot air engine presented as a heat engine that allows the conversion of heat into mechanical energy while heat supply can be external. In the contribution are compared cycles of hot-air engine. Then are compared suitable heat exchangers for use with hot air Ericsson-Brayton engine. In the final part is proposal of heat exchanger for use in closed Ericsson-Brayton cycle.

  12. Heat exchanger design for hot air ericsson-brayton piston engine

    Science.gov (United States)

    Ďurčanský, P.; Lenhard, R.; Jandačka, J.

    2014-03-01

    One of the solutions without negative consequences for the increasing energy consumption in the world may be use of alternative energy sources in micro-cogeneration. Currently it is looking for different solutions and there are many possible ways. Cogeneration is known for long time and is widely used. But the installations are often large and the installed output is more suitable for cities or industry companies. When we will speak about decentralization, the small machines have to be used. The article deals with the principle of hot-air engines, their use in combined heat and electricity production from biomass and with heat exchangers as primary energy transforming element. In the article is hot air engine presented as a heat engine that allows the conversion of heat into mechanical energy while heat supply can be external. In the contribution are compared cycles of hot-air engine. Then are compared suitable heat exchangers for use with hot air Ericsson-Brayton engine. In the final part is proposal of heat exchanger for use in closed Ericsson-Brayton cycle.

  13. Adaptability of Brayton cycle conversion systems to fast, epithermal and thermal spectrum space nuclear reactors

    International Nuclear Information System (INIS)

    Tilliette, Z.P.

    1988-01-01

    The two French Government Agencies C.N.E.S. (Centre National d'Etudes Spatiales) and C.E.A. (Commissariat a l'Energie Atomique) are carrying out joint preliminary studies on space nuclear power systems for future ARIANE 5 launch vehicle applications. The Brayton cycle is the reference conversion system, whether the heat source is a liquid metal-cooled (NaK, Na or Li) reactor or a gas-cooled direct cycle concept. The search for an adequate utilization of this energy conversion means has prompted additional evaluations featuring the definition of satisfactory cycle conditions for these various kinds of reactor concepts. In addition to firstly studied fast and epithermal spectrum ones, thermal spectrum reactors can offer an opportunity of bringing out some distinctive features of the Brayton cycle, in particular for the temperature conditioning of the efficient metal hydrides (ZrH, Li/sub 7/H) moderators. One of the purposes of the paper is to confirm the potential of long lifetime ZrH moderated reactors associated with a gas cycle and to assess the thermodynamical consequences for both Nak(Na)-cooled or gas-cooled nuclear heat sources. This investigation is complemented by the definition of appropriate reactor arrangements which could be presented on a further occasion

  14. Dynamic simulation of 10 kW Brayton cryocooler for HTS cable

    Science.gov (United States)

    Chang, Ho-Myung; Park, Chan Woo; Yang, Hyung Suk; Hwang, Si Dole

    2014-01-01

    Dynamic simulation of a Brayton cryocooler is presented as a partial effort of a Korean governmental project to develop 1˜3 km HTS cable systems at transmission level in Jeju Island. Thermodynamic design of a 10 kW Brayton cryocooler was completed, and a prototype construction is underway with a basis of steady-state operation. This study is the next step to investigate the transient behavior of cryocooler for two purposes. The first is to simulate and design the cool-down process after scheduled or unscheduled stoppage. The second is to predict the transient behavior following the variation of external conditions such as cryogenic load or outdoor temperature. The detailed specifications of key components, including plate-fin heat exchangers and cryogenic turbo-expanders are incorporated into a commercial software (Aspen HYSYS) to estimate the temporal change of temperature and flow rate over the cryocooler. An initial cool-down scenario and some examples on daily variation of cryocooler are presented and discussed, aiming at stable control schemes of a long cable system.

  15. Dynamic simulation of 10 kW Brayton cryocooler for HTS cable

    International Nuclear Information System (INIS)

    Chang, Ho-Myung; Park, Chan Woo; Yang, Hyung Suk; Hwang, Si Dole

    2014-01-01

    Dynamic simulation of a Brayton cryocooler is presented as a partial effort of a Korean governmental project to develop 1∼3 km HTS cable systems at transmission level in Jeju Island. Thermodynamic design of a 10 kW Brayton cryocooler was completed, and a prototype construction is underway with a basis of steady-state operation. This study is the next step to investigate the transient behavior of cryocooler for two purposes. The first is to simulate and design the cool-down process after scheduled or unscheduled stoppage. The second is to predict the transient behavior following the variation of external conditions such as cryogenic load or outdoor temperature. The detailed specifications of key components, including plate-fin heat exchangers and cryogenic turbo-expanders are incorporated into a commercial software (Aspen HYSYS) to estimate the temporal change of temperature and flow rate over the cryocooler. An initial cool-down scenario and some examples on daily variation of cryocooler are presented and discussed, aiming at stable control schemes of a long cable system

  16. Study of reverse Brayton cryocooler with Helium-Neon mixture for HTS cable

    Science.gov (United States)

    Dhillon, A. K.; Ghosh, P.

    2017-12-01

    As observed in the earlier studies, helium is more efficient than neon as a refrigerant in a reverse Brayton cryocooler (RBC) from the thermodynamic point of view. However, the lower molecular weight of helium leads to higher refrigerant inventory as compared to neon. Thus, helium is suitable to realize the high thermodynamic efficiency of RBC whereas neon is appropriate for the compactness of the RBC. A binary mixture of helium and neon can be used to achieve high thermodynamic efficiency in the compact reverse Brayton cycle (RBC) based cryocooler. In this paper, an attempt has been made to analyze the thermodynamic performance of the RBC with a binary mixture of helium and neon as the working fluid to provide 1 kW cooling load for high temperature superconductor (HTS) power cables working with a temperature range of 50 K to 70 K. The basic RBC is simulated using Aspen HYSYS V8.6®, a commercial process simulator. Sizing of each component based on the optimized process parameters for each refrigerant is performed based on a computer code developed using Engineering Equation Solver (EES-V9.1). The recommendation is provided for the optimum mixture composition of the refrigerant based on the trade-off factors like thermodynamic efficiency such as the exergy efficiency and equipment considerations. The outcome of this study may be useful for recommending a suitable refrigerant for the RBC operating at a temperature level of 50 K to 70 K.

  17. Dynamic simulation of 10 kW Brayton cryocooler for HTS cable

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Ho-Myung; Park, Chan Woo [Hong Ik University, Department of Mechanical Engineering, Seoul, 121-791 (Korea, Republic of); Yang, Hyung Suk; Hwang, Si Dole [KEPCO Research Institute, Daejeon, 305-760 (Korea, Republic of)

    2014-01-29

    Dynamic simulation of a Brayton cryocooler is presented as a partial effort of a Korean governmental project to develop 1∼3 km HTS cable systems at transmission level in Jeju Island. Thermodynamic design of a 10 kW Brayton cryocooler was completed, and a prototype construction is underway with a basis of steady-state operation. This study is the next step to investigate the transient behavior of cryocooler for two purposes. The first is to simulate and design the cool-down process after scheduled or unscheduled stoppage. The second is to predict the transient behavior following the variation of external conditions such as cryogenic load or outdoor temperature. The detailed specifications of key components, including plate-fin heat exchangers and cryogenic turbo-expanders are incorporated into a commercial software (Aspen HYSYS) to estimate the temporal change of temperature and flow rate over the cryocooler. An initial cool-down scenario and some examples on daily variation of cryocooler are presented and discussed, aiming at stable control schemes of a long cable system.

  18. Thermodynamic analysis and optimization of a Closed Regenerative Brayton Cycle for nuclear space power systems

    International Nuclear Information System (INIS)

    Ribeiro, Guilherme B.; Braz Filho, Francisco A.; Guimarães, Lamartine N.F.

    2015-01-01

    Nuclear power systems turned to space electric propulsion differ strongly from usual ground-based power systems regarding the importance of overall size and mass. For propulsion power systems, size and mass are essential drivers that should be minimized during conception processes. Considering this aspect, this paper aims the development of a design-based model of a Closed Regenerative Brayton Cycle that applies the thermal conductance of the main components in order to predict the energy conversion performance, allowing its use as a preliminary tool for heat exchanger and radiator panel sizing. The centrifugal-flow turbine and compressor characterizations were achieved using algebraic equations from literature data. A binary mixture of Helium–Xenon with molecular weight of 40 g/mole is applied and the impact of the components sizing in the energy efficiency is evaluated in this paper, including the radiator panel area. Moreover, an optimization analysis based on the final mass of heat the exchangers is performed. - Highlights: • A design-based model of a Closed Brayton Cycle is proposed for nuclear space needs. • Turbomachinery efficiency presented a strong influence on the system efficiency. • Radiator area presented the highest potential to increase the system efficiency. • There is maximum system efficiency for each total mass of heat exchangers. • Size or efficiency optimization was performed by changing heat exchanger proportion.

  19. Improvement of supercritical CO2 Brayton cycle using binary gas mixture

    International Nuclear Information System (INIS)

    Jeong, Woo Seok

    2011-02-01

    A Sodium-cooled Fast Reactor (SFR) is one of the strongest candidates for the next generation nuclear reactor. However, the conventional design of a SFR concept with an indirect Rankine cycle is inevitably subjected to a sodium-water reaction. To prevent hazardous situation caused by sodium-water reaction, the SFR with Brayton cycle using Supercritical Carbon dioxide (S-CO 2 cycle) as a working fluid can be an alternative approach. The S-CO 2 Brayton cycle is more sensitive to the critical point of working fluids than other Brayton cycles. This is because compressor work significantly decreases at slightly above the critical point due to high density near the boundary between the supercritical state and the subcritical state. For this reason, the minimum temperature and pressure of cycle are just above the CO 2 critical point. The critical point acts as a limitation of the lowest operating condition of the cycle. In general, lowering the rejection temperature of a thermodynamic cycle increases the efficiency and thus, changing the critical point of CO 2 can result in an improvement of the total cycle efficiency with the same cycle layout. Modifying the critical point of the working fluid can be done by adding other gases to CO 2 . The direction and range of the CO 2 critical point variation depends on the mixed component and its amount. In particular, chemical reactivity of the gas mixture itself and the gas mixture with sodium at high temperatures are of interest. To modify the critical point of the working fluid, several gases were chosen as candidates by which chemical stability with sodium within the interested range of cycle operating condition was assured: CO 2 was mixed with N 2 , O 2 , He, Ar and Xe. To evaluate the effect of shifting the critical point and changes in the properties of the S-CO 2 Brayton cycle, a supercritical Brayton cycle analysis code connected with the REFPROP program from the NIST was developed. The developed code is for evaluating

  20. Closed Brayton Cycle Power Conversion Unit for Fission Surface Power Phase I Final Report

    Science.gov (United States)

    Fuller, Robert L.

    2010-01-01

    A Closed Brayton cycle power conversion system has been developed to support the NASA fission surface power program. The goal is to provide electricity from a small nuclear reactor heat source for surface power production for lunar and Mars environments. The selected media for a heat source is NaK 78 with water as a cooling source. The closed Brayton cycle power was selected to be 12 kWe output from the generator terminals. A heat source NaK temperature of 850 K plus or minus 25 K was selected. The cold source water was selected at 375 K plus or minus 25 K. A vacuum radiation environment of 200 K is specified for environmental operation. The major components of the system are the power converter, the power controller, and the top level data acquisition and control unit. The power converter with associated sensors resides in the vacuum radiation environment. The power controller and data acquisition system reside in an ambient laboratory environment. Signals and power are supplied across the pressure boundary electrically with hermetic connectors installed on the vacuum vessel. System level analyses were performed on working fluids, cycle design parameters, heater and cooling temperatures, and heat exchanger options that best meet the needs of the power converter specification. The goal is to provide a cost effective system that has high thermal-to-electric efficiency in a compact, lightweight package.

  1. Analysis of a 115MW, 3 shaft, helium Brayton cycle

    International Nuclear Information System (INIS)

    Pradeepkumar, K.N.

    2002-01-01

    This research theme is originated from a development project that is going on in South Africa, for the design and construction of a closed cycle gas turbine plant using gas-cooled reactor as the heat source to generate 115 MW of electricity. South African Power utility company, Eskorn, promotes this developmental work through its subsidiary called PBMR (Pebble Bed Modular Reactor). Some of the attractive features of this plant are the inherent and passive safety features, modular geometry, small evacuation area, small infrastructure requirements for the installation and running of the plant, small construction time, quick starting and stopping and also low operational cost. This exercise is looking at the operational aspects of a closed cycle gas turbine, the finding of which will have a direct input towards the successful development and commissioning of the plant. A thorough understanding of the fluid dynamics in this three-shaft system and its transient performance analysis were the two main objectives of this research work. A computer programme called GTSI, developed by a previous Cranfield University research student, has been used in this as a base programme for the performance analysis. Some modifications were done on this programme to improve its control abilities. The areas covered in the performance analysis are Start-up, Shutdown and Load ramping. A detailed literature survey has been conducted to learn from the helium Turbo machinery experiences, though it is very limited. A critical analysis on the design philosophy of the PBMR is also carried out as part of this research work. The performance analysis has shown the advantage, disadvantage and impact of various power modulation methods suggested for the PBMR. It has tracked the effect of the operations of the various valves included in the PBMR design. The start-up using a hot gas injection has been analysed in detail and a successful start region has been mapped. A start-up procedure is also written

  2. Brayton Cycle Numerical Modeling using the RELAP5-3D code, version 4.3.4

    Energy Technology Data Exchange (ETDEWEB)

    Longhini, Eduardo P.; Lobo, Paulo D.C.; Guimarães, Lamartine N.F.; Filho, Francisco A.B.; Ribeiro, Guilherme B., E-mail: edu_longhini@yahoo.com.br [Instituto de Estudos Avançados (IEAv), São José dos Campos, SP (Brazil). Divisão de Energia Nuclear

    2017-07-01

    This work contributes to enable and develop technologies to mount fast micro reactors, to generate heat and electric energy, for the purpose to warm and to supply electrically spacecraft equipment and, also, the production of nuclear space propulsion effect. So, for this purpose, the Brayton Cycle demonstrates to be an optimum approach for space nuclear power. The Brayton thermal cycle gas has as characteristic to be a closed cycle, with two adiabatic processes and two isobaric processes. The components performing the cycle's processes are compressor, turbine, heat source, cold source and recuperator. Therefore, the working fluid's mass flow runs the thermal cycle that converts thermal energy into electrical energy, able to use in spaces and land devices. The objective is numerically to model the Brayton thermal cycle gas on nominal operation with one turbomachine composed for a radial-inflow compressor and turbine of a 40.8 kWe Brayton Rotating Unit (BRU). The Brayton cycle numerical modeling is being performed with the program RELAP5-3D, version 4.3.4. The nominal operation uses as working fluid a mixture 40 g/mole He-Xe with a flow rate of 1.85 kg/s, shaft rotational speed of 45 krpm, compressor and turbine inlet temperature of 400 K and 1149 K, respectively, and compressor exit pressure 0.931 MPa. Then, the aim is to get physical corresponding data to operate each cycle component and the general cycle on this nominal operation. (author)

  3. Brayton Cycle Numerical Modeling using the RELAP5-3D code, version 4.3.4

    International Nuclear Information System (INIS)

    Longhini, Eduardo P.; Lobo, Paulo D.C.; Guimarães, Lamartine N.F.; Filho, Francisco A.B.; Ribeiro, Guilherme B.

    2017-01-01

    This work contributes to enable and develop technologies to mount fast micro reactors, to generate heat and electric energy, for the purpose to warm and to supply electrically spacecraft equipment and, also, the production of nuclear space propulsion effect. So, for this purpose, the Brayton Cycle demonstrates to be an optimum approach for space nuclear power. The Brayton thermal cycle gas has as characteristic to be a closed cycle, with two adiabatic processes and two isobaric processes. The components performing the cycle's processes are compressor, turbine, heat source, cold source and recuperator. Therefore, the working fluid's mass flow runs the thermal cycle that converts thermal energy into electrical energy, able to use in spaces and land devices. The objective is numerically to model the Brayton thermal cycle gas on nominal operation with one turbomachine composed for a radial-inflow compressor and turbine of a 40.8 kWe Brayton Rotating Unit (BRU). The Brayton cycle numerical modeling is being performed with the program RELAP5-3D, version 4.3.4. The nominal operation uses as working fluid a mixture 40 g/mole He-Xe with a flow rate of 1.85 kg/s, shaft rotational speed of 45 krpm, compressor and turbine inlet temperature of 400 K and 1149 K, respectively, and compressor exit pressure 0.931 MPa. Then, the aim is to get physical corresponding data to operate each cycle component and the general cycle on this nominal operation. (author)

  4. Development of the System Dynamics Code using Homogeneous Equilibrium Model for S-CO{sub 2} Brayton cycle Transient Analyses

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Seong Jun; Lee, Won Woong; Oh, Bongseong; Lee, Jeong Ik [KAIST, Daejeon (Korea, Republic of)

    2016-10-15

    The features of the S-CO{sub 2} Brayton cycle come from a small compressing work by designing the compressor inlet close the critical point of CO{sub 2}. This means the system condition can be operating under two-phase or sub-critical phase during transient situations such as changes of cooling system performance, load variations, etc. Since there is no operating MW scale S-CO{sub 2} Brayton cycle system in the world yet, using an analytical code is the only way to predict the system behavior and develop operating strategies of the S-CO{sub 2} Brayton cycles. Therefore, the development of a credible system code is an important part for the practical S-CO{sub 2} system research. The current status of the developed system analysis code for S-CO{sub 2} Brayton cycle transient analyses in KAIST and verification results are presented in this paper. To avoid errors related with convergences of the code during the phase changing flow calculation in GAMMA+ code, the authors have developed a system analysis code using Homogeneous Equilibrium Model (HEM) for the S-CO{sub 2} Brayton cycle transient analysis. The backbone of the in-house code is the GAMMA+1.0 code, but treating the quality of fluid by tracking system enthalpy gradient every time step. Thus, the code adopts pressure and enthalpy as the independent scalar variables to track the system enthalpy for updating the quality of the system every time step. The heat conduction solving method, heat transfer correlation and frictional losses on the pipe are referred from the GAMMA+ code.

  5. Safety and feasibility of laparoscopic colo-rectal surgery for cancer at a tertiary center in a developing country: Egypt as an

    Directory of Open Access Journals (Sweden)

    Anwar Tawfik Amin

    2015-06-01

    Conclusion: Laparoscopic colorectal surgery for cancer in developing countries could be safe and feasible. Safe reuse of disposable expensive parts of some laparoscopic instruments could help in propagation of this technique in developing countries.

  6. Ion Prostate Irradiation (IPI) – a pilot study to establish the safety and feasibility of primary hypofractionated irradiation of the prostate with protons and carbon ions in a raster scan technique

    International Nuclear Information System (INIS)

    Habl, Gregor; Herfarth, Klaus; Hatiboglu, Gencay; Edler, Lutz; Uhl, Matthias; Krause, Sonja; Roethke, Matthias; Schlemmer, Heinz P; Hadaschik, Boris; Debus, Juergen

    2014-01-01

    Due to physical characteristics, ions like protons or carbon ions can administer the dose to the target volume more efficiently than photons since the dose can be lowered at the surrounding normal tissue. Radiation biological considerations are based on the assumption that the α/β value for prostate cancer cells is 1.5 Gy, so that a biologically more effective dose could be administered due to hypofractionation without increasing risks of late effects of bladder (α/β = 4.0) and rectum (α/β = 3.9). The IPI study is a prospective randomized phase II study exploring the safety and feasibility of primary hypofractionated irradiation of the prostate with protons and carbon ions in a raster scan technique. The study is designed to enroll 92 patients with localized prostate cancer. Primary aim is the assessment of the safety and feasibility of the study treatment on the basis of incidence grade III and IV NCI-CTC-AE (v. 4.02) toxicity and/or the dropout of the patient from the planned therapy due to any reason. Secondary endpoints are PSA-progression free survival (PSA-PFS), overall survival (OS) and quality-of-life (QoL). This pilot study aims at the evaluation of the safety and feasibility of hypofractionated irradiation of the prostate with protons and carbon ions in prostate cancer patients in an active beam technique. Additionally, the safety results will be compared with Japanese results recently published for carbon ion irradiation. Due to the missing data of protons in this hypofractionated scheme, an in depth evaluation of the toxicity will be created to gain basic data for a following comparison study with carbon ion irradiation. Clinical Trial Identifier: http://clinicaltrials.gov/show/NCT01641185 (clinicaltrials.gov)

  7. Study on the coupling performance of a turboexpander compressor applied in cryogenic reverse Brayton air refrigerator

    International Nuclear Information System (INIS)

    Yang, Shanju; Chen, Shuangtao; Chen, Xingya; Zhang, Xingqun; Hou, Yu

    2016-01-01

    Highlights: • Numerical simulations on expansion and compression processes were carried out. • A coupling model was built based on analysis and simulation and verified by test. • Relations and interactions among coupling parameters were quantitatively described. • When T_0_C = 0.39 MPa, the cooling capacity of refrigerator reached 221 W at 129.6 K. - Abstract: A small cryogenic reverse Brayton air refrigerator with turboexpander compressor (TEC) is presented in this study. Because of stable process, simple matching between expander and brake blower, and easy regulation, a turboexpander with brake blower is usually used in small reverse Brayton refrigerator. However, a turboexpander with brake blower just consumes and wastes the output energy during the enthalpy drop. In contrast, the output energy of TEC is absorbed by its coupled compressor for recycling. Thus when employing a TEC, the reverse Brayton refrigerator will achieve lower refrigeration temperature, larger cooling capacity and more effective energy use. TEC overall performance, which has an important impact on the refrigerator thermal performance, is mainly determined by the coupling between expander and compressor. In a TEC, the compressor and expander should seek balance among energy, rotating speed, mass flow rate and pressure, though restricted by individual working characteristics. The coupling relations among compressor efficiency, expander efficiency, compressor pressure ratio and expander expansion ratio are quite complex. In this study, theoretical coupling analysis between expander and compressor was conducted. The aerodynamic performances of compressor and expander were calculated using CFX simulation with SST model. The performance curves of compressor and expander were obtained through simulation results, which were validated by experimental data. Based on the coupling analysis and numerical simulations, the automatic coupling model between compression process and expansion process

  8. Concept Design for a High Temperature Helium Brayton Cycle with Interstage Heating and Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Wright, Steven A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Vernon, Milton E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Pickard, Paul S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2013-12-01

    The primary metric for the viability of these next generation nuclear power plants will be the cost of generated electricity. One important component in achieving these objectives is the development of power conversion technologies that maximize the electrical power output of these advanced reactors for a given thermal power. More efficient power conversion systems can directly reduce the cost of nuclear generated electricity and therefore advanced power conversion cycle research is an important area of investigation for the Generation IV Program. Brayton cycles using inert or other gas working fluids, have the potential to take advantage of the higher outlet temperature range of Generation IV systems and allow substantial increases in nuclear power conversion efficiency, and potentially reductions in power conversion system capital costs compared to the steam Rankine cycle used in current light water reactors. For the Very High Temperature Reactor (VHTR), Helium Brayton cycles which can operate in the 900 to 950 C range have been the focus of power conversion research. Previous Generation IV studies examined several options for He Brayton cycles that could increase efficiency with acceptable capital cost implications. At these high outlet temperatures, Interstage Heating and Cooling (IHC) was shown to provide significant efficiency improvement (a few to 12%) but required increased system complexity and therefore had potential for increased costs. These scoping studies identified the potential for increased efficiency, but a more detailed analysis of the turbomachinery and heat exchanger sizes and costs was needed to determine whether this approach could be cost effective. The purpose of this study is to examine the turbomachinery and heat exchanger implications of interstage heating and cooling configurations. In general, this analysis illustrates that these engineering considerations introduce new constraints to the design of IHC systems that may require

  9. NERI Quarterly Progress Report -- April 1 - June 30, 2005 -- Development of a Supercritical Carbon Dioxide Brayton Cycle: Improving PBR Efficiency and Testing Material Compatibility

    International Nuclear Information System (INIS)

    Chang Oh

    2005-01-01

    The objective of this research is to improve a helium Brayton cycle and to develop a supercritical carbon dioxide Brayton cycle for the Pebble Bed Reactor (PBR) that can also be applied to the Fast Gas-Cooled Reactor (FGR) and the Very-High-Temperature Gas-Cooled Reactor (VHTR). The proposed supercritical carbon dioxide Brayton cycle will be used to improve the PBR, FGR, and VHTR net plant efficiency. Another objective of this research is to test materials to be used in the power conversion side at supercritical carbon dioxide conditions. Generally, the optimized Brayton cycle and balance of plant (BOP) to be developed from this study can be applied to Generation-IV reactor concepts. Particularly, we are interested in VHTR because it has a good chance of being built in the near future

  10. FY-05 Second Quarter Report On Development of a Supercritical Carbon Dioxide Brayton Cycle: Improving PBR Efficiency and Testing Material Compatibility

    International Nuclear Information System (INIS)

    Chang Oh

    2005-01-01

    The objective of this research is to improve a helium Brayton cycle and to develop a supercritical carbon dioxide Brayton cycle for the Pebble Bed Reactor (PBR) that can also be applied to the Fast Gas-Cooled Reactor (FGR) and the Very-High-Temperature Gas-Cooled Reactor (VHTR). The proposed supercritical carbon dioxide Brayton cycle will be used to improve the PBR, FGR, and VHTR net plant efficiency. Another objective of this research is to test materials to be used in the power conversion side at supercritical carbon dioxide conditions. Generally, the optimized Brayton cycle and balance of plant (BOP) to be developed from this study can be applied to Generation-IV reactor concepts. Particularly, we are interested in VHTR because it has a good chance of being built in the near future

  11. Brayton Isotope Power System. Phase I. (Ground demonstration system) Configuration Control Document (CCD)

    International Nuclear Information System (INIS)

    1976-01-01

    The configuration control document (CCD) defines the BIPS-GDS configuration. The GDS configuration is similar to a conceptual flight system design, referred to as the BIPS-FS, which is discussed in App. I. The BIPS is being developed by ERDA as a 500 to 2000 W(e), 7-y life, space power system utilizing a closed Brayton cycle gas turbine engine to convert thermal energy (from an isotope heat source) to electrical energy at a net efficiency exceeding 25 percent. The CCD relates to Phase I of an ERDA Program to qualify a dynamic system for launch in the early 1980's. Phase I is a 35-month effort to provide an FS conceptual design and GDS design, fabrication, and test. The baseline is a 7-year life, 450-pound, 4800 W(t), 1300 W(e) system which will use two multihundred watt (MHW) isotope heat sources being developed

  12. Isotope Brayton ground demonstration testing and flight qualification. Volume 1. Technical program

    Energy Technology Data Exchange (ETDEWEB)

    1974-12-09

    A program is proposed for the ground demonstration, development, and flight qualification of a radioisotope nuclear heated dynamic power system for use on space missions beginning in the 1980's. This type of electrical power system is based upon and combines two aerospace technologies currently under intense development; namely, the MHW isotope heat source and the closed Brayton cycle gas turbine. This power system represents the next generation of reliable, efficient economic electrical power equipment for space, and will be capable of providing 0.5 to 2.0 kW of electric power to a wide variety of spacecraft for earth orbital and interplanetary missions. The immediate design will be based upon the requirements for the Air Force SURVSATCOM mission. The proposal is presented in three volumes plus an Executive Summary. This volume describes the tasks in the technical program.

  13. Conceptual design study of closed Brayton cycle gas turbines for fusion power generation

    International Nuclear Information System (INIS)

    Kuo, S.C.

    1976-01-01

    A conceptual design study is presented of closed Brayton cycle gas turbine power conversion systems suitable for integration with advanced-concept Tokamak fusion reactors (such as UWMAK-III) for efficient power generation without requiring cooling water supply for waste heat rejection. A baseline cycle configuration was selected and parametric performance analyses were made. Based on the results of the parametric analysis and trade-off and interface considerations, the reference design conditions for the baseline cycle were selected. Conceptual designs were made of the major helium gas turbine power system components including a 585-MWe single-shaft turbomachine, (three needed), regenerator, precooler, intercooler, and the piping system connecting them. Structural configuration and significant physical dimensions for major components are illustrated, and a brief discussion on major advantages, power control and crucial technologies for the helium gas turbine power system are presented

  14. Regenerator optimization of a Closed Brayton Cycle via entropy generation minimization

    Energy Technology Data Exchange (ETDEWEB)

    Araújo, Élvis Falcão de; Ribeiro, Guilherme Borges; Guimarães, Lamartine N. F., E-mail: falcao@ieav.cta.br, E-mail: gbribeiro@ieav.cta.br, E-mail: guimarae@ieav.cta.br [Instituto de Estudos Avançacados (IEAv), São José dos Campos, SP (Brazil). Div. de Energia Nuclear

    2017-07-01

    This paper aims the numerical study of the heat transfer and fluid flow of a Closed Brayton Cycle (CBC) regenerator that is part of TERRA microreactor. This regenerator consists in a cross flow heat exchanger, where heat transfer occurs between internal fluid flow in radial tubes and external fluid flow passing perpendicularly to the tubes, which are disposed in a symmetrical cylindrical set where the number of tubes in the axial and radial directions can vary. In the simulations, mass flow inlet is varied for a fixed geometry. The fluid flow solution is provided by a commercial CFD solver and the entropy generation number calculation is later computed for optimization purposes. As a result, the entropy minimization method provides the regenerator configuration that enables the highest energy conversion efficiency. (author)

  15. Design and fabrication of gas bearings for Brayton cycle rotating unit

    Science.gov (United States)

    Frost, A.; Tessarzik, J. M.; Arwas, E. B.; Waldron, W. D. (Editor)

    1973-01-01

    Analysis, design, and testing of two types of pivoted pad journal bearings and a spiral-grooved thrust bearing suitable for direct installation into the NASA 2 to 15 KW Brayton Cycle Rotating Unit (BRU) have been accomplished. Both types of tilting pad bearing assemblies are of the preloaded type, consisting of three pads with one pad flexibly mounted. One type utilizes a non-conforming pivot, while the other replaces the conventional spherical pivot with a cruciform flexible member. The thrust bearing is flexure mounted to accommodate static machine mislinement. Test results indicate that both types of journal bearings should satisfy the requirements imposed by the BRU. Hydrostatic tests of the spiral-grooved thrust bearing showed it to be free of pneumatic hammer with as many as 24 orifices over the BRU pressure and load range.

  16. Cycle Design of Reverse Brayton Cryocooler for HTS Cable Cooling Using Exergy Analysis

    Science.gov (United States)

    Gupta, Sudeep Kumar; Ghosh, Parthasarathi

    2017-02-01

    The reliability and price of cryogenic refrigeration play an important role in the successful commercialization of High Temperature Superconducting (HTS) cables. For cooling HTS cable, sub-cooled liquid nitrogen (LN2) circulation system is used. One of the options to maintain LN2 in its sub-cooled state is by providing refrigeration with the help of Reverse Brayton Cryo-cooler (RBC). The refrigeration requirement is 10 kW for continuously sub-cooling LN2 from 72 K to 65 K for cooling 1 km length of HTS cable [1]. In this paper, a parametric evaluation of RBC for sub-cooling LN2 has been performed using helium as a process fluid. Exergy approach has been adopted for this analysis. A commercial process simulator, Aspen HYSYS® V8.6 has been used for this purpose. The critical components have been identified and their exergy destruction and exergy efficiency have been obtained for a given heat load condition.

  17. Regenerator optimization of a Closed Brayton Cycle via entropy generation minimization

    International Nuclear Information System (INIS)

    Araújo, Élvis Falcão de; Ribeiro, Guilherme Borges; Guimarães, Lamartine N. F.

    2017-01-01

    This paper aims the numerical study of the heat transfer and fluid flow of a Closed Brayton Cycle (CBC) regenerator that is part of TERRA microreactor. This regenerator consists in a cross flow heat exchanger, where heat transfer occurs between internal fluid flow in radial tubes and external fluid flow passing perpendicularly to the tubes, which are disposed in a symmetrical cylindrical set where the number of tubes in the axial and radial directions can vary. In the simulations, mass flow inlet is varied for a fixed geometry. The fluid flow solution is provided by a commercial CFD solver and the entropy generation number calculation is later computed for optimization purposes. As a result, the entropy minimization method provides the regenerator configuration that enables the highest energy conversion efficiency. (author)

  18. Heat exchanger optimization of a closed Brayton cycle for nuclear space propulsion

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Guilherme B.; Guimaraes, Lamartine N.F.; Braz Filho, Francisco A., E-mail: gbribeiro@ieav.cta.br, E-mail: guimarae@ieav.cta.br, E-mail: braz@ieav.cta.br [Instituto de Estudos Avancados (IEAV), Sao Jose dos Campos, SP (Brazil). Divisao de Energia Nuclear

    2015-07-01

    Nuclear power systems turned to space electric propulsion differs strongly from usual ground-based power systems regarding the importance of overall size and weight. For propulsion power systems, weight and efficiency are essential drivers that should be managed during conception phase. Considering that, this paper aims the development of a thermal model of a closed Brayton cycle that applies the thermal conductance of heat exchangers in order to predict the energy conversion performance. The centrifugal-flow turbine and compressor characterization were achieved using algebraic equations from literature data. The binary mixture of He-Xe with molecular weight of 40 g/mole is applied and the impact of heat exchanger optimization in thermodynamic irreversibilities is evaluated in this paper. (author)

  19. Heat exchanger optimization of a closed Brayton cycle for nuclear space propulsion

    International Nuclear Information System (INIS)

    Ribeiro, Guilherme B.; Guimaraes, Lamartine N.F.; Braz Filho, Francisco A.

    2015-01-01

    Nuclear power systems turned to space electric propulsion differs strongly from usual ground-based power systems regarding the importance of overall size and weight. For propulsion power systems, weight and efficiency are essential drivers that should be managed during conception phase. Considering that, this paper aims the development of a thermal model of a closed Brayton cycle that applies the thermal conductance of heat exchangers in order to predict the energy conversion performance. The centrifugal-flow turbine and compressor characterization were achieved using algebraic equations from literature data. The binary mixture of He-Xe with molecular weight of 40 g/mole is applied and the impact of heat exchanger optimization in thermodynamic irreversibilities is evaluated in this paper. (author)

  20. Promising designs of compact heat exchangers for modular HTRs using the Brayton cycle

    International Nuclear Information System (INIS)

    Pra, Franck; Tochon, Patrice; Mauget, Christian; Fokkens, Jan; Willemsen, Sander

    2008-01-01

    The presented study was carried out within the Work Package 2 'Recuperator' of the High Temperature Reactor-E European program. High Temperature gas cooled Reactor concepts with a direct cycle have become potentially interesting for the future. Theoretically, these concepts provide higher efficiency than a classical steam cycle. Within the Brayton cycle the helium/helium recuperator, required to achieve the high efficiency, has to work under very harsh conditions (temperature, pressure, and pressure difference between circuits). Within the project the most promising technologies for the compact recuperator were investigated. First, the requirements for the recuperator to operate under the direct Brayton cycle have been defined. Based on these requirements the various potential technologies available on the market have been investigated. Two particular technologies (HEATRIC Printed Circuit Heat Exchanger, NORDON plate fin concept) have been selected as most promising. For the former, a precise description has been given and a mock-up has been fabricated and tested in the Claire loop at CEA. In the Claire loop the Printed Circuit Heat Exchanger mock-up has been subjected to thermal shocks, which are considered to be representative for a recuperator. Prior to the experimental testing coupled Computational Fluid Dynamic (CFD) and Finite Element analyses have been performed to give insight into the thermal and mechanical behaviour of the mock-ups during the thermal shock. Based on these results the experimental measuring program has been optimized. Upon completion of the tests the experimental and numerical results have been compared. Based on the results from the investigation performed recommendations are given for the full-size recuperator using the selected technologies

  1. Optimization of Brayton cycles for low-to-moderate grade thermal energy sources

    International Nuclear Information System (INIS)

    Rovira, Antonio; Muñoz-Antón, Javier; Montes, María José; Martínez-Val, José María

    2013-01-01

    Future electricity generation will involve low or moderate temperature technologies. In such a scenario, optimisation of thermodynamic cycles will be a key task. This work presents a systematic analysis to find the operating regime where Brayton cycles reach the highest efficiency, using real substances and given heat source and sink temperatures. Several configurations using fluids close to its critical point at the compressor inlet are considered. Irreversibility sources are carefully analysed, as well as the type of working fluid. The analysis is performed by means of a theoretical approach to obtain some trends, which are afterwards validated with real gases. Results show that the efficiency and the specific work improve if the compressor inlet is close to the critical point. Furthermore, these cycles are less sensitive to pressure drops and politropic efficiencies than those working with ideal gases. The above features are more evident when the ratio of heat source and heat sink temperatures is low. The selection of the gas becomes a fundamental issue in this quest. Critical temperature should be close to ambient temperature, low critical pressure is advisable and the R/c p factor measured at the ideal gas condition should be low to further enhance the efficiency. - Highlights: • Performance analysis of Brayton cycles with the compressor inlet close to the critical point. • Cycles are not very sensitive to pressure drops and isentropic efficiencies of the compressor. • Gas selection becomes important, regarding the critical pressure and temperature as well as the kind of fluid. • R/c p factor measured at the ideal gas condition should be as low as possible

  2. Potential advantages of coupling supercritical CO2 Brayton cycle to water cooled small and medium size reactor

    International Nuclear Information System (INIS)

    Yoon, Ho Joon; Ahn, Yoonhan; Lee, Jeong Ik; Addad, Yacine

    2012-01-01

    Highlights: ► S-CO 2 cycle as candidate for SMS. ► MATLAB code used for S-CO 2 cycle analysis. ► Pressure ratio and split ratio comparison analyzed. - Abstract: The supercritical carbon dioxide (S-CO 2 ) Brayton cycle is being considered as a favorable candidate for the next generation nuclear reactors power conversion systems. Major benefits of the S-CO 2 Brayton cycle compared to other Brayton cycles are: (1) high thermal efficiency in relatively low turbine inlet temperature, (2) compactness of the turbomachineries and heat exchangers and (3) simpler cycle layout at an equivalent or superior thermal efficiency. However, these benefits can be still utilized even in the water-cooled reactor technologies under special circumstances. A small and medium size water-cooled nuclear reactor (SMR) has been gaining interest due to its wide range of application such as electricity generation, seawater desalination, district heating and propulsion. Another key advantage of a SMR is that it can be transported from one place to another mostly by maritime transport due to its small size, and sometimes even through a railway system. Therefore, the combination of a S-CO 2 Brayton cycle with a SMR can reinforce any advantages coming from its small size if the S-CO 2 Brayton cycle has much smaller size components, and simpler cycle layout compared to the currently considered steam Rankine cycle. In this paper, SMART (System-integrated Modular Advanced ReacTor), a 330 MW th integral reactor developed by KAERI (Korea Atomic Energy Institute) for multipurpose utilization, is considered as a potential candidate for applying the S-CO 2 Brayton cycle and advantages and disadvantages of the proposed system will be discussed in detail. In consideration of SMART condition, the turbine inlet pressure and size of heat exchangers are analyzed by using in-house code developed by KAIST–Khalifa University joint research team. According to the cycle evaluation, the maximum cycle efficiency

  3. Performance analysis of a large-scale helium Brayton cryo-refrigerator with static gas bearing turboexpander

    International Nuclear Information System (INIS)

    Zhang, Yu; Li, Qiang; Wu, Jihao; Li, Qing; Lu, Wenhai; Xiong, Lianyou; Liu, Liqiang; Xu, Xiangdong; Sun, Lijia; Sun, Yu; Xie, Xiujuan; Wang, Bingming; Qiu, Yinan; Zhang, Peng

    2015-01-01

    Highlights: • A 2 kW at 20.0 K helium Brayton cryo-refrigerator is built in China. • A series of tests have been systematically conducted to investigate the performance of the cryo-refrigerator. • Maximum heat conductance proportion (90.7%) appears in the heat exchangers of cold box rather than those of heat reservoirs. • A model of helium Brayton cryo-refrigerator/cycle is presented according to finite-time thermodynamics. - Abstract: Large-scale helium cryo-refrigerator is widely used in superconducting systems, nuclear fusion engineering, and scientific researches, etc., however, its energy efficiency is quite low. First, a 2 kW at 20.0 K helium Brayton cryo-refrigerator is built, and a series of tests have been systematically conducted to investigate the performance of the cryo-refrigerator. It is found that maximum heat conductance proportion (90.7%) appears in the heat exchangers of cold box rather than those of heat reservoirs, which is the main characteristic of the helium Brayton cryo-refrigerator/cycle different from the air Brayton refrigerator/cycle. Other three characteristics also lie in the configuration of refrigerant helium bypass, internal purifier and non-linearity of specific heat of helium. Second, a model of helium Brayton cryo-refrigerator/cycle is presented according to finite-time thermodynamics. The assumption named internal purification temperature depth (PTD) is introduced, and the heat capacity rate of whole cycle is divided into three different regions in accordance with the PTD: room temperature region, upper internal purification temperature region and lower one. Analytical expressions of cooling capacity and COP are obtained, and we found that the expressions are piecewise functions. Further, comparison between the model and the experimental results for cooling capacity of the helium cryo-refrigerator shows that error is less than 7.6%. The PTD not only helps to achieve the analytical formulae and indicates the working

  4. Initial estimates of the economical attractiveness of a nuclear closed Brayton combined cycle operating with firebrick resistance-heated energy storage

    Directory of Open Access Journals (Sweden)

    Florian Chavagnat

    2018-04-01

    Full Text Available The Firebrick Resistance-Heated Energy Storage (FIRES concept developed by the Massachusetts Institute of Technology aims to enhance profitability of the nuclear power industry in the next decades. Studies carried out at Massachusetts Institute of Technology already provide estimates of the potential revenue from FIRES system when it is applied to industrial heat supply, the likely first application. Here, we investigate the possibility of operating a power plant (PP with a fluoride-salt-cooled high-temperature reactor and a closed Brayton cycle. This variant offers features such as enhanced nuclear safety as well as flexibility in design of the PP but also radically changes the way of operating the PP. This exploratory study provides estimates of the revenue generated by FIRES in addition to the nominal revenue of the stand-alone fluoride-salt-cooled high-temperature reactor, which are useful for defining an initial design. The electricity price data is based on the day-ahead markets of Germany/Austria and the United States (Iowa. The proposed method derives from the equation of revenue introduced in this study and involves simple computations using MatLab to compute the estimates. Results show variable economic potential depending on the host grid but stress a high profitability in both regions. Keywords: Firebrick Resistance-Heated Energy Storage, Nuclear Power Plant, Revenue Estimate, Storage System

  5. Local rhBMP-12 on an Absorbable Collagen Sponge as an Adjuvant Therapy for Rotator Cuff Repair - A Phase 1, Randomized, Standard of Care Control, Multicenter Study: Safety and Feasibility.

    Science.gov (United States)

    Greiner, Stefan; Ide, Junji; Van Noort, Arthur; Mochizuki, Yu; Ochi, Hiroshi; Marraffino, Shannon; Sridharan, Sudhakar; Rudicel, Sally; Itoi, Eiji

    2015-08-01

    Recombinant human bone morphogenetic protein-12 (rhBMP-12) has been shown to induce tendon and ligament formation in rats and to improve tendon healing; however, the safety and feasibility of implanting rhBMP-12/absorbable collagen sponge (ACS) in humans are not known. To investigate the safety and feasibility of rhBMP-12 on an ACS as an adjuvant therapy in open rotator cuff repair. Randomized controlled trial; Level of evidence, 2. This study consisted of 20 patients with full-thickness rotator cuff tears. Patients were randomized either to standard of care (SOC) treatment (open rotator cuff repair) or to receive 0.015 mg/mL rhBMP-12/ACS and SOC treatment during their open rotator cuff repair (rhBMP-12/ACS group) at a rate of 1/4 SOC/rhBMP-12/ACS. The feasibility of implanting the product and the safety of the product were evaluated during the 1-year follow-up period. The evaluation involved up to 10 postoperative visits, which included physical examinations, radiographs, computed tomography (CT) scans, magnetic resonance imaging (MRI) scans with an emphasis on heterotopic ossification (HO), pharmacokinetics, immunogenicity, laboratory evaluations, and local and systemic adverse events at specified time points. Small amounts of HO were seen on follow-up CT scans in 10 of 16 patients in the rhBMP-12/ACS group and in 2 of 3 patients in the SOC group. HO did not increase at 26 weeks and was not associated with any adverse events or unsatisfactory clinical outcomes. Pharmacokinetics demonstrated that circulating levels of rhBMP-12 were not detectable after administration. Five of 16 patients showed a postoperative immunogenic response but did not show any correlating adverse events. Complete healing of the rotator cuff was observed in 14 of 16 patients; 2 of 16 imaging results could not be analyzed because of artifacts in the rhBMP-12 group on MRI scans. In the SOC group, 1 of 4 patients showed a retear at 12 weeks after surgery. The use of rhBMP-12/ACS has been shown

  6. Comparison between reverse Brayton and Kapitza based LNG boil-off gas reliquefaction system using exergy analysis

    Science.gov (United States)

    Kochunni, Sarun Kumar; Chowdhury, Kanchan

    2017-02-01

    LNG boil-off gas (BOG) reliquefaction systems in LNG carrier ships uses refrigeration devices which are based on reverse Brayton, Claude, Kapitza (modified Claude) or Cascade cycles. Some of these refrigeration devices use nitrogen as the refrigerants and hence nitrogen storage vessels or nitrogen generators needs to be installed in LNG carrier ships which consume space and add weight to the carrier. In the present work, a new configuration based on Kapitza liquefaction cycle which uses BOG itself as working fluid is proposed and has been compared with Reverse Brayton Cycle (RBC) on sizes of heat exchangers and compressor operating parameters. Exergy analysis is done after simulating at steady state with Aspen Hysys 8.6® and the comparison between RBC and Kapitza may help designers to choose reliquefaction system with appropriate process parameters and sizes of equipment. With comparable exergetic efficiency as that of an RBC, a Kaptiza system needs only BOG compressor without any need of nitrogen gas.

  7. Experimental Investigation from the Operation of a 2 kW Brayton Power Conversion Unit and a Xenon Ion Thruster

    Science.gov (United States)

    Hervol, David; Mason, Lee; Birchenough, Art; Pinero, Luis

    2004-01-01

    A 2kW Brayton Power Conversion Unit (PCU) and a xenon ion thruster were integrated with a Power Management and Distribution (PMAD) system as part of a Nuclear Electric Propulsion (NEP) Testbed at NASA's Glenn Research Center. Brayton Converters and ion thrusters are potential candidates for use on future high power NEP mission such as the proposed Jupiter Icy Moons Orbiter (JIMO). The use of a existing lower power test hardware provided a cost effective means to investigate the critical electrical interface between the power conversion system and the propulsion system. The testing successfully demonstrated compatible electrical operations between the converter and the thruster, including end-to-end electric power throughput, high efficiency AC to DC conversion, and thruster recycle fault protection. The details of this demonstration are reported herein.

  8. Experimental Investigations from the Operation of a 2 Kw Brayton Power Conversion Unit and a Xenon Ion Thruster

    Science.gov (United States)

    Mason, Lee; Birchenough, Arthur; Pinero, Luis

    2004-01-01

    A 2 kW Brayton Power Conversion Unit (PCU) and a xenon ion thruster were integrated with a Power Management and Distribution (PMAD) system as part of a Nuclear Electric Propulsion (NEP) Testbed at NASA's Glenn Research Center. Brayton converters and ion thrusters are potential candidates for use on future high power NEP missions such as the proposed Jupiter Icy Moons Orbiter (JIMO). The use of existing lower power test hardware provided a cost-effective means to investigate the critical electrical interface between the power conversion system and ion propulsion system. The testing successfully demonstrated compatible electrical operations between the converter and the thruster, including end-to-end electric power throughput, high efficiency AC to DC conversion, and thruster recycle fault protection. The details of this demonstration are reported herein.

  9. An evaluation of thermodynamic solar plants with cylindrical parabolic collectors and air turbine engines with open Joule–Brayton cycle

    International Nuclear Information System (INIS)

    Ferraro, Vittorio; Marinelli, Valerio

    2012-01-01

    A performance analysis of innovative solar plants operating with cylindrical parabolic collectors and atmospheric air as heat transfer fluid in an open Joule–Brayton cycle, with and without intercooling and regeneration, is presented. The analysis was made for two operating modes of the plants: with variable air flow rate and constant inlet temperature to the turbine and with constant flow rate and variable inlet temperature to the turbine. The obtained results show a good performance of this type of solar plant, in spite of its simplicity; it seems able to compete well with other more complex plants operating with different heat transfer fluids. -- Highlights: ► Innovative CPS solar plants, operating with air in open Joule–Brayton cycle, are proposed. ► They are attractive for their simplicity and present interesting values of global efficiency. ► They seem able to compete well with other more complex solar plants.

  10. Method for controlling start-up and steady state performance of a closed split flow recompression brayton cycle

    Science.gov (United States)

    Pasch, James Jay

    2017-02-07

    A method of resolving a balanced condition that generates control parameters for start-up and steady state operating points and various component and cycle performances for a closed split flow recompression cycle system. The method provides for improved control of a Brayton cycle thermal to electrical power conversion system. The method may also be used for system design, operational simulation and/or parameter prediction.

  11. Multi-objective thermodynamic optimization of an irreversible regenerative Brayton cycle using evolutionary algorithm and decision making

    OpenAIRE

    Rajesh Kumar; S.C. Kaushik; Raj Kumar; Ranjana Hans

    2016-01-01

    Brayton heat engine model is developed in MATLAB simulink environment and thermodynamic optimization based on finite time thermodynamic analysis along with multiple criteria is implemented. The proposed work investigates optimal values of various decision variables that simultaneously optimize power output, thermal efficiency and ecological function using evolutionary algorithm based on NSGA-II. Pareto optimal frontier between triple and dual objectives is obtained and best optimal value is s...

  12. Potential performance improvement using a reacting gas (nitrogin tetroxide) as the working fluid in a closed Brayton cycle

    Science.gov (United States)

    Stochl, R. J.

    1979-01-01

    The results of an analysis to estimate the performance that could be obtained by using a chemically reacting gas (nitrogen tetroxide) as the working fluid in a closed Brayton cycle are presented. Compared with data for helium as the working fluid, these results indicate efficiency improvements from 4 to 90 percent, depending on turbine inlet temperature, pressures, and gas residence time in heat transfer equipment.

  13. Feasibility study

    International Nuclear Information System (INIS)

    Gibbs, P.; Kalas, P.

    1975-01-01

    The feasibility study itself examines the technical, economic and financial implications of a nuclear power station in depth so as to make sure that nuclear power is the right course to take. This means that it is quite an expensive operation and it is to avoid wasting this money that a pre-feasibility study is carried out. This preliminary study should eliminate cases where the electrical system cannot absorb the capacity of a nuclear station of commercial size, where other sources of power such as hydro-electricity, gas or cheap coal would make nuclear obviously uneconomic or where no suitable sites exist. If this first rather simple survey shows that nuclear power is a credible solution to a utilities need for electricity or heat production plant, then the next stage is a full feasibility study. (orig./TK) [de

  14. Development of the ANL plant dynamics code and control strategies for the supercritical carbon dioxide Brayton cycle and code validation with data from the Sandia small-scale supercritical carbon dioxide Brayton cycle test loop.

    Energy Technology Data Exchange (ETDEWEB)

    Moisseytsev, A.; Sienicki, J. J. (Nuclear Engineering Division)

    2011-11-07

    Significant progress has been made in the ongoing development of the Argonne National Laboratory (ANL) Plant Dynamics Code (PDC), the ongoing investigation and development of control strategies, and the analysis of system transient behavior for supercritical carbon dioxide (S-CO{sub 2}) Brayton cycles. Several code modifications have been introduced during FY2011 to extend the range of applicability of the PDC and to improve its calculational stability and speed. A new and innovative approach was developed to couple the Plant Dynamics Code for S-CO{sub 2} cycle calculations with SAS4A/SASSYS-1 Liquid Metal Reactor Code System calculations for the transient system level behavior on the reactor side of a Sodium-Cooled Fast Reactor (SFR) or Lead-Cooled Fast Reactor (LFR). The new code system allows use of the full capabilities of both codes such that whole-plant transients can now be simulated without additional user interaction. Several other code modifications, including the introduction of compressor surge control, a new approach for determining the solution time step for efficient computational speed, an updated treatment of S-CO{sub 2} cycle flow mergers and splits, a modified enthalpy equation to improve the treatment of negative flow, and a revised solution of the reactor heat exchanger (RHX) equations coupling the S-CO{sub 2} cycle to the reactor, were introduced to the PDC in FY2011. All of these modifications have improved the code computational stability and computational speed, while not significantly affecting the results of transient calculations. The improved PDC was used to continue the investigation of S-CO{sub 2} cycle control and transient behavior. The coupled PDC-SAS4A/SASSYS-1 code capability was used to study the dynamic characteristics of a S-CO{sub 2} cycle coupled to a SFR plant. Cycle control was investigated in terms of the ability of the cycle to respond to a linear reduction in the electrical grid demand from 100% to 0% at a rate of 5

  15. Enhanced arrangement for recuperators in supercritical CO2 Brayton power cycle for energy conversion in fusion reactors

    International Nuclear Information System (INIS)

    Serrano, I.P.; Linares, J.I.; Cantizano, A.; Moratilla, B.Y.

    2014-01-01

    Highlights: •We propose an enhanced power conversion system layout for a Model C fusion reactor. •Proposed layout is based on a modified recompression supercritical CO 2 Brayton cycle. •New arrangement in recuperators regards to classical cycle is used. •High efficiency is achieved, comparable with the best obtained in complex solutions. -- Abstract: A domestic research program called TECNO F US was launched in Spain in 2009 to support technological developments related to a dual coolant breeding blanket concept for fusion reactors. This concept of blanket uses Helium (300 °C/400 °C) to cool part of it and a liquid metal (480 °C/700 °C) to cool the rest; it also includes high temperature (700 °C/800 °C) and medium temperature (566 °C/700 °C) Helium cooling circuits for divertor. This paper proposes a new layout of the classical recompression supercritical CO 2 Brayton cycle which replaces one of the recuperators (the one with the highest temperature) by another which by-passes the low temperature blanket source. This arrangement allows reaching high turbine inlet temperatures (around 600 °C) with medium pressures (around 225 bar) and achieving high cycle efficiencies (close to 46.5%). So, the proposed cycle reveals as a promising design because it integrates all the available thermal sources in a compact layout achieving high efficiencies with the usual parameters prescribed in classical recompression supercritical CO 2 Brayton cycles

  16. Application of exergetic sustainability index to a nano-scale irreversible Brayton cycle operating with ideal Bose and Fermi gasses

    Energy Technology Data Exchange (ETDEWEB)

    Açıkkalp, Emin, E-mail: eacikkalp@gmail.com [Department of Mechanical and Manufacturing Engineering, Engineering Faculty, Bilecik S.E. University, Bilecik (Turkey); Caner, Necmettin [Department of Chemistry, Faculty of Arts and Sciences, Eskisehir Osmangazi University, Eskisehir (Turkey)

    2015-09-25

    Highlights: • An irreversible Brayton cycle operating quantum gasses is considered. • Exergetic sustainability index is derived for nano-scale cycles. • Nano-scale effects are considered. • Calculation are conducted for irreversible cycles. • Numerical results are presented and discussed. - Abstract: In this study, a nano-scale irreversible Brayton cycle operating with quantum gasses including Bose and Fermi gasses is researched. Developments in the nano-technology cause searching the nano-scale machines including thermal systems to be unavoidable. Thermodynamic analysis of a nano-scale irreversible Brayton cycle operating with Bose and Fermi gasses was performed (especially using exergetic sustainability index). In addition, thermodynamic analysis involving classical evaluation parameters such as work output, exergy output, entropy generation, energy and exergy efficiencies were conducted. Results are submitted numerically and finally some useful recommendations were conducted. Some important results are: entropy generation and exergetic sustainability index are affected mostly for Bose gas and power output and exergy output are affected mostly for the Fermi gas by x. At the high temperature conditions, work output and entropy generation have high values comparing with other degeneracy conditions.

  17. Optimization of airfoil-type PCHE for the recuperator of small scale brayton cycle by cost-based objective function

    International Nuclear Information System (INIS)

    Kwon, Jin Gyu; Kim, Tae Ho; Park, Hyun Sun; Cha, Jae Eun; Kim, Moo Hwan

    2016-01-01

    Highlights: • Suggest the Nusselt number and Fanning friction factor correlation for airfoil-type PCHE. • Show that cost-based optimization is available to airfoil-type PCHE. • Suggest the recuperator design for SCIEL test loop at KAERI by cost-based objective function with correlations from numerical analysis. - Abstract: Supercritical carbon dioxide (SCO_2) Brayton cycle gives high efficiency of power cycle with small size. Printed circuit heat exchangers (PCHE) are proper selection for the Brayton cycle because their operability at high temperature and high pressure with small size. Airfoil fin PCHE was suggested by Kim et al. (2008b), it can provide high heat transfer-like zigzag channel PCHE with low pressure drop-like straight channel PCHE. Optimization of the airfoil fin PCHE was not performed like the zigzag channel PCHE. For optimization of the airfoil fin PCHE, the operating condition of the recuperator of SCO_2 Integral Experiment Loop (SCIEL) Brayton cycle test loop at Korea Atomic Energy Research Institute (KAERI) was used. We performed CFD analysis for various airfoil fin configurations using ANSYS CFX 15.0, and made correlations for predicting the Nusselt number and the Fanning friction factor. The recuperator was designed by the simple energy balance code with our correlations. Using the cost-based objective function with production cost and operation cost from size and pressure drop of the recuperator, we evaluated airfoil fin configuration by using total cost and suggested the optimization configuration of the airfoil fin PCHE.

  18. Optimization of airfoil-type PCHE for the recuperator of small scale brayton cycle by cost-based objective function

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Jin Gyu [Division of Advanced Nuclear Engineering, POSTECH, Pohang 790-784 (Korea, Republic of); Kim, Tae Ho [Department of Mechanical Engineering, POSTECH, Pohang 790-784 (Korea, Republic of); Park, Hyun Sun, E-mail: hejsunny@postech.ac.kr [Division of Advanced Nuclear Engineering, POSTECH, Pohang 790-784 (Korea, Republic of); Cha, Jae Eun [Korea Atomic Energy Research Institute, Daejeon 305-353 (Korea, Republic of); Kim, Moo Hwan [Division of Advanced Nuclear Engineering, POSTECH, Pohang 790-784 (Korea, Republic of); Korea Institute of Nuclear Safety, Daejeon 305-338 (Korea, Republic of)

    2016-03-15

    Highlights: • Suggest the Nusselt number and Fanning friction factor correlation for airfoil-type PCHE. • Show that cost-based optimization is available to airfoil-type PCHE. • Suggest the recuperator design for SCIEL test loop at KAERI by cost-based objective function with correlations from numerical analysis. - Abstract: Supercritical carbon dioxide (SCO{sub 2}) Brayton cycle gives high efficiency of power cycle with small size. Printed circuit heat exchangers (PCHE) are proper selection for the Brayton cycle because their operability at high temperature and high pressure with small size. Airfoil fin PCHE was suggested by Kim et al. (2008b), it can provide high heat transfer-like zigzag channel PCHE with low pressure drop-like straight channel PCHE. Optimization of the airfoil fin PCHE was not performed like the zigzag channel PCHE. For optimization of the airfoil fin PCHE, the operating condition of the recuperator of SCO{sub 2} Integral Experiment Loop (SCIEL) Brayton cycle test loop at Korea Atomic Energy Research Institute (KAERI) was used. We performed CFD analysis for various airfoil fin configurations using ANSYS CFX 15.0, and made correlations for predicting the Nusselt number and the Fanning friction factor. The recuperator was designed by the simple energy balance code with our correlations. Using the cost-based objective function with production cost and operation cost from size and pressure drop of the recuperator, we evaluated airfoil fin configuration by using total cost and suggested the optimization configuration of the airfoil fin PCHE.

  19. Supercritical CO2 Brayton cycle compression and control near the critical point

    International Nuclear Information System (INIS)

    Wright, S. A.; Fuller, R.; Noall, J.; Radel, R.; Vernon, M. E.; Pickard, P. S.

    2008-01-01

    This report describes the supercritical compression and control issues, the analysis, and the measured test results of a small-scale supercritical CO 2 (S-CO 2 ) compression test-loop. The test loop was developed by Sandia and is described in a companion paper in this conference. The results of these experiments will for the first time evaluate and experimentally demonstrate supercritical compression and the required compressor inlet control approaches on an appropriate scale in a series of test loops at Sandia National Laboratories. The Sandia effort is focused on the main compressor of a supercritical Brayton loop while a separate DOE Gen lV program focus is on studying similar behavior in re-compression Brayton cycles that have dual compressors. One of the main goals of this program is to develop and demonstrate the ability to design, operate, and control the supercritical compression process near the critical point due to highly non-linear behavior near this point. This Sandia supercritical test-loop uses a 50 kW radial compressor to pump supercritical CO 2 (S-CO 2 ) through an orifice and through a water-cooled gas-chiller. At the design point the compressor flow rate is 3.5 kg/s, the inlet pressure is 7, 690 kPa, the pressure ratio is 1.8, the inlet temperature is 305 K, and the shaft speed is 75, 000 rpm. The purpose of the loop is to study the compression and control issues near the critical point. To study compression we intend to compare the design code predictions for efficiency and change in enthalpy (or pressure ratio / head) of the radial compressor with the measured results from actual tests. In the tests the inlet flow, temperature, and pressure, will be varied around the critical point of CO 2 (Tc=304.2 K, and Pc=7.377 MPa). To study control, the test loop will use a variety of methods including inventory control, shaft speed control, and cooling water flow rate, and cooling water temperature control methods to set the compressor inlet temperature

  20. A closed Brayton power conversion unit concept for nuclear electric propulsion for deep space missions

    International Nuclear Information System (INIS)

    Joyner, Claude Russell II; Fowler, Bruce; Matthews, John

    2003-01-01

    In space, whether in a stable satellite orbit around a planetary body or traveling as a deep space exploration craft, power is just as important as the propulsion. The need for power is especially important for in-space vehicles that use Electric Propulsion. Using nuclear power with electric propulsion has the potential to provide increased payload fractions and reduced mission times to the outer planets. One of the critical engineering and design aspects of nuclear electric propulsion at required mission optimized power levels is the mechanism that is used to convert the thermal energy of the reactor to electrical power. The use of closed Brayton cycles has been studied over the past 30 or years and shown to be the optimum approach for power requirements that range from ten to hundreds of kilowatts of power. It also has been found to be scalable to higher power levels. The Closed Brayton Cycle (CBC) engine power conversion unit (PCU) is the most flexible for a wide range of power conversion needs and uses state-of-the-art, demonstrated engineering approaches. It also is in use with many commercial power plants today. The long life requirements and need for uninterrupted operation for nuclear electric propulsion demands high reliability from a CBC engine. A CBC engine design for use with a Nuclear Electric Propulsion (NEP) system has been defined based on Pratt and Whitney's data from designing long-life turbo-machines such as the Space Shuttle turbopumps and military gas turbines and the use of proven integrated control/health management systems (EHMS). An integrated CBC and EHMS design that is focused on using low-risk and proven technologies will over come many of the life-related design issues. This paper will discuss the use of a CBC engine as the power conversion unit coupled to a gas-cooled nuclear reactor and the design trends relative to its use for powering electric thrusters in the 25 kWe to 100kWe power level

  1. Study protocol for the FITR Heart Study: Feasibility, safety, adherence, and efficacy of high intensity interval training in a hospital-initiated rehabilitation program for coronary heart disease

    Directory of Open Access Journals (Sweden)

    Jenna Taylor

    2017-12-01

    Conclusions: This study aims to address the ongoing concerns regarding the practicality and safety of HIIT in CR programs. We anticipate study findings will lead to the development of a standardized protocol to facilitate CR programs to incorporate HIIT as a standard exercise option for appropriate patients.

  2. Report to the Congress on the need for, and the feasibility of, establishing a security agency within the Office of Nuclear Material Safety and Safeguards. Executive summary

    International Nuclear Information System (INIS)

    1976-08-01

    The Executive Summary of a report written in response to the Congressional mandate Section 204(b)-(2) (c) of the Energy Reorganization Act of 1974, by the Director of the Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory Commission (NRC) is given. It summarizes the main report, which assessed guard force effectiveness, and addressed public policy, administration and legal issues

  3. Feasibility and safety of transfemoral intra-arterial chemotherapy for head and neck cancer using a 3-French catheter system: comparison with a 4-French catheter system.

    Science.gov (United States)

    Watanabe, Shigeru; Yamamoto, Akira; Torigoe, Teruyuki; Kanki, Akihiko; Tamada, Tsutomu; Ito, Katsuyoshi

    2016-02-01

    To assess the technical feasibility of transfemoral intra-arterial chemotherapy for head and neck cancer using a 3-French catheter system (3-Fr). Sixty-two patients with head and neck cancer who underwent transfemoral intra-arterial chemotherapy were included in this study. Thirty-three patients underwent treatment using a 3-Fr (group 3-Fr). Twenty-nine patients underwent treatment using a 4-French catheter system (group 4-Fr). The technical success rate, duration of the procedure with fluoroscopy, and rate of procedure-related complications were compared between group 3-Fr and group 4-Fr. In addition, in group 3-Fr, bleeding at the puncture site after 1.5 h of bed rest was evaluated. The technical success rate was 100% in both groups. The duration of the procedure with fluoroscopy didn't differ between group 3-Fr (mean 28.0 min) and group 4-Fr (mean 30.2 min) (p = 0.524). There was no procedure-related complication in either group. In group 3-Fr, no hemorrhagic complication was observed. A 3-French catheter system can be used to perform transfemoral intra-arterial chemotherapy for head and neck cancer and is technically feasible with approximately the same duration of the procedure with fluoroscopy. Furthermore, this method may shorten the bed rest time without hemorrhagic complication, and may reduce the risk of pulmonary embolism.

  4. Advances in defining a closed brayton conversion system for future ARIANE 5 space nuclear power applications

    International Nuclear Information System (INIS)

    Tilliette, Z.P.

    1986-06-01

    The present European ARIANE space program will expand into the large ARIANE 5 launch vehicle from 1995. It is assumed that important associated missions would require the generation of 200 kWe or more in space during several years at the very beginning of the next century. It is the reason why, in 1983, the French C.N.E.S. (Centre National d'Etudes Spatiales) and C.E.A. (Commissariat a l'Energie Atomique) have initiated preliminary studies of a space nuclear power system. The currently selected conversion system is a closed Brayton cycle. Reasons for this choice are given: high efficiency of a dynamic system; monophasic, inert working fluid; extensive turbomachinery experience, etc... A key aspect of the project is the adaptation to the heat rejection conditions, namely to the radiator geometry which depends upon the dimensions of the ARIANE 5 spacecraft. In addition to usual concepts already studied for space applications, another cycle arrangement is being investigated which could offer satisfactory compromises among many considerations, increase the efficiency of the system and make it more attractive as far as the specific mass (kg/kWe), the specific radiator area (m 2 /kWe) and various technological aspects are concerned. Comparative details are presented

  5. Thermodynamics Properties of Binary Gas Mixtures for Brayton Space Nuclear Power System

    International Nuclear Information System (INIS)

    You Ersheng; Shi Lei; Zhang Zuoyi

    2014-01-01

    Space nuclear power system with closed Brayton cycle has the potential advantages of high cycle efficiency. It can be achieved to limit the specific mass of the system with a competitive design scheme, so as to strengthen the advantage of the nuclear energy applying in space propulsion and electric generating compared to solar or chemical propellant. Whereby, the thermodynamic properties of working fluids have a significant influence on the performance of the plant. Therefore, two binary mixtures helium-nitrogen and helium-carbon dioxide are introduced to analysis the variation in the transport and heat transfer capacity of working fluids. Based on the parameters of pure gases, the heat transfer coefficient, pressure losses and aerodynamic loading are calculated as a function of mole fraction at the temperature of 400 K and 1200 K, as well as the typical operating pressure of 2 MPa. Results indicated that the mixture of helium-carbon dioxide with a mole fraction of 0.4 is a more attractive choice for the high heat transfer coefficient, low aerodynamic loading and acceptable pressure losses in contrast to helium-nitrogen and other mixing ratios of helium-carbon dioxide. Its heat transfer coefficient is almost 20% more than that of pure helium and the normalized aerodynamic loading is less than 34% at 1200 K. However; the pressure losses are a little higher with ~3.5 times those of pure helium. (author)

  6. Brayton cycle for internal combustion engine exhaust gas waste heat recovery

    Directory of Open Access Journals (Sweden)

    J Galindo

    2015-06-01

    Full Text Available An average passenger car engine effectively uses about one-third of the fuel combustion energy, while the two-thirds are wasted through exhaust gases and engine cooling. It is of great interest to automotive industry to recover some of this wasted energy, thus increasing the engine efficiency and lowering fuel consumption and contamination. Waste heat recovery for internal combustion engine exhaust gases using Brayton cycle machine was investigated. The principle problems of application of such a system in a passenger car were considered: compressor and expander machine selection, machine size for packaging under the hood, efficiency of the cycle, and improvement of engine efficiency. Important parameters of machines design have been determined and analyzed. An average 2-L turbocharged gasoline engine’s New European Driving Cycle points were taken as inlet points for waste heat recovery system. It is theoretically estimated that the recuperated power of 1515 W can be achieved along with 5.7% improvement in engine efficiency, at the point where engine power is 26550 W.

  7. Status of the CNES-CEA joint program on space nuclear Brayton systems

    International Nuclear Information System (INIS)

    Carre, F.; Proust, E.; Chaudourne, S.; Keirle, P.; Tilliette, Z.; Vrillon, B.

    1989-01-01

    A cooperative program between the French Centre National d'Etudes Spatiales (CNES) and the Commissariat a l'Energie Atomique (CEA) was initiated in 1983, to investigate the possible development of 20 to 200 kWe space nuclear power systems to be launched by the next version of the European launcher, Ariane V. After completion in 1986 of preliminary conceptual studies of a reference 200 kWe turbo-electric power system, an additional 3 year study phase was decided, with the double objective of assessing the potential advantage of nuclear power systems versus solar photovoltaic or dynamic systems in the 20 kWe power range, and comparing various reactor candidate technologies and system options for 20 kWe space nuclear power systems, likely to meet the projected energy needs of future European space missions. A comprehensive program including conceptual design studies, operating transient analyses and technology base assessment, is currently applied to a few reference concepts of 20 kWe nuclear Brayton and thermoelectric systems, in order to establish sound technical and economical bases for selecting the design options and the development strategy of a first space nuclear power system in Europe

  8. CFD aided approach to design printed circuit heat exchangers for supercritical CO2 Brayton cycle application

    International Nuclear Information System (INIS)

    Kim, Seong Gu; Lee, Youho; Ahn, Yoonhan; Lee, Jeong Ik

    2016-01-01

    Highlights: • CFD analyses were performed to find performance of PCHE for supercritical CO 2 power cycle. • CFD results were obtained beyond the limits of existing correlations. • Designs of different PCHEs with different correlations were compared. • A new CFD-aided correlation covering a wider Reynolds number range was proposed. - Abstract: While most conventional PCHE designs for working fluid of supercritical CO 2 require an extension of valid Reynolds number limits of experimentally obtained correlations, Computational Fluid Dynamics (CFD) code ANSYS CFX was used to explore validity of existing correlations beyond their tested Reynolds number ranges. For heat transfer coefficient correlations, an appropriate piece-wising with Ishizuka’s and Hesselgreaves’s correlation is found to enable an extension of Reynolds numbers. For friction factors, no single existing correlation is found to capture different temperature and angular dependencies for a wide Reynolds number range. Based on the comparison of CFD results with the experimentally obtained correlations, a new CFD-aided correlation covering an extended range of Reynolds number 2000–58,000 for Nusselt number and friction factor is proposed to facilitate PCHE designs for the supercritical CO 2 Brayton cycle application.

  9. Performance analysis for an irreversible variable temperature heat reservoir closed intercooled regenerated Brayton cycle

    International Nuclear Information System (INIS)

    Wang Wenhua; Chen Lingen; Sun Fengrui; Wu Chih

    2003-01-01

    In this paper, the theory of finite time thermodynamics is used in the performance analysis of an irreversible closed intercooled regenerated Brayton cycle coupled to variable temperature heat reservoirs. The analytical formulae for dimensionless power and efficiency, as functions of the total pressure ratio, the intercooling pressure ratio, the component (regenerator, intercooler, hot and cold side heat exchangers) effectivenesses, the compressor and turbine efficiencies and the thermal capacity rates of the working fluid and the heat reservoirs, the pressure recovery coefficients, the heat reservoir inlet temperature ratio, and the cooling fluid in the intercooler and the cold side heat reservoir inlet temperature ratio, are derived. The intercooling pressure ratio is optimized for optimal power and optimal efficiency, respectively. The effects of component (regenerator, intercooler and hot and cold side heat exchangers) effectivenesses, the compressor and turbine efficiencies, the pressure recovery coefficients, the heat reservoir inlet temperature ratio and the cooling fluid in the intercooler and the cold side heat reservoir inlet temperature ratio on optimal power and its corresponding intercooling pressure ratio, as well as optimal efficiency and its corresponding intercooling pressure ratio are analyzed by detailed numerical examples. When the heat transfers between the working fluid and the heat reservoirs are executed ideally, the pressure drop losses are small enough to be neglected and the thermal capacity rates of the heat reservoirs are infinite, the results of this paper replicate those obtained in recent literature

  10. Thermodynamic analyses and optimization of a recompression N2O Brayton power cycle

    International Nuclear Information System (INIS)

    Sarkar, Jahar

    2010-01-01

    Thermodynamic analyses and simultaneous optimizations of cycle pressure ratio and flow split fraction to get maximum efficiency of N 2 O recompression Brayton cycle have been performed to study the effects of various operating conditions and component performances. The energetic as well as exergetic performance comparison with its counterpart recompression CO 2 cycle is presented as well. Optimization shows that the optimum minimum cycle pressure is close to pseudo-critical pressure for supercritical cycle, whereas saturation pressure corresponding to minimum cycle temperature for condensation cycle. Results show that the maximum thermal efficiency increases with decrease in minimum cycle temperature and increase in both maximum cycle pressure and temperature. Influence of turbine performance on cycle efficiency is more compared to that of compressors, HTR (high temperature recuperator) and LTR (low temperature recuperator). Comparison shows that N 2 O gives better thermal efficiency (maximum deviation of 1.2%) as well as second law efficiency compared to CO 2 for studied operating conditions. Component wise irreversibility distribution shows the similar trends for both working fluids. Present study reveals that N 2 O is a potential option for the recompression power cycle.

  11. High Temperature Fusion Reactor Cooling Using Brayton Cycle Based Partial Energy Conversion

    Science.gov (United States)

    Juhasz, Albert J.; Sawicki, Jerzy T.

    2003-01-01

    For some future space power systems using high temperature nuclear heat sources most of the output energy will be used in other than electrical form, and only a fraction of the total thermal energy generated will need to be converted to electrical work. The paper describes the conceptual design of such a partial energy conversion system, consisting of a high temperature fusion reactor operating in series with a high temperature radiator and in parallel with dual closed cycle gas turbine (CCGT) power systems, also referred to as closed Brayton cycle (CBC) systems, which are supplied with a fraction of the reactor thermal energy for conversion to electric power. Most of the fusion reactor's output is in the form of charged plasma which is expanded through a magnetic nozzle of the interplanetary propulsion system. Reactor heat energy is ducted to the high temperature series radiator utilizing the electric power generated to drive a helium gas circulation fan. In addition to discussing the thermodynamic aspects of the system design the authors include a brief overview of the gas turbine and fan rotor-dynamics and proposed bearing support technology along with performance characteristics of the three phase AC electric power generator and fan drive motor.

  12. Safety and feasibility of minimally invasive gastrectomy during the early introduction in the Netherlands: short-term oncological outcomes comparable to open gastrectomy.

    Science.gov (United States)

    Brenkman, H J F; Ruurda, J P; Verhoeven, R H A; van Hillegersberg, R

    2017-09-01

    Minimally invasive techniques for gastric cancer surgery have recently been introduced in the Netherlands, based on a proctoring program. The aim of this population-based cohort study was to evaluate the short-term oncological outcomes of minimally invasive gastrectomy (MIG) during its introduction in the Netherlands. The Netherlands Cancer Registry identified all patients with gastric adenocarcinoma who underwent gastrectomy with curative intent between 2010 and 2014. Multivariable analysis was performed to compare MIG and open gastrectomy (OG) on lymph node yield (≥15), R0 resection rate, and 1-year overall survival. The pooled learning curve per center of MIG was evaluated by groups of five subsequent procedures. Between 2010 and 2014, a total of 277 (14%) patients underwent MIG and 1633 (86%) patients underwent OG. During this period, the use of MIG and neoadjuvant chemotherapy increased from 4% to 39% (p introduction of minimally invasive gastrectomy in Western countries is feasible and can be performed safely.

  13. Safety and feasibility of pulmonary artery pressure-guided heart failure therapy: rationale and design of the prospective CardioMEMS Monitoring Study for Heart Failure (MEMS-HF).

    Science.gov (United States)

    Angermann, Christiane E; Assmus, Birgit; Anker, Stefan D; Brachmann, Johannes; Ertl, Georg; Köhler, Friedrich; Rosenkranz, Stephan; Tschöpe, Carsten; Adamson, Philip B; Böhm, Michael

    2018-05-19

    Wireless monitoring of pulmonary artery (PA) pressures with the CardioMEMS HF™ system is indicated in patients with New York Heart Association (NYHA) class III heart failure (HF). Randomized and observational trials have shown a reduction in HF-related hospitalizations and improved quality of life in patients using this device in the United States. MEMS-HF is a prospective, non-randomized, open-label, multicenter study to characterize safety and feasibility of using remote PA pressure monitoring in a real-world setting in Germany, The Netherlands and Ireland. After informed consent, adult patients with NYHA class III HF and a recent HF-related hospitalization are evaluated for suitability for permanent implantation of a CardioMEMS™ sensor. Participation in MEMS-HF is open to qualifying subjects regardless of left ventricular ejection fraction (LVEF). Patients with reduced ejection fraction must be on stable guideline-directed pharmacotherapy as tolerated. The study will enroll 230 patients in approximately 35 centers. Expected duration is 36 months (24-month enrolment plus ≥ 12-month follow-up). Primary endpoints are freedom from device/system-related complications and freedom from pressure sensor failure at 12-month post-implant. Secondary endpoints include the annualized rate of HF-related hospitalization at 12 months versus the rate over the 12 months preceding implant, and health-related quality of life. Endpoints will be evaluated using data obtained after each subject's 12-month visit. The MEMS-HF study will provide robust evidence on the clinical safety and feasibility of implementing haemodynamic monitoring as a novel disease management tool in routine out-patient care in selected European healthcare systems. ClinicalTrials.gov; NCT02693691.

  14. Potential improvements of supercritical recompression CO2 Brayton cycle by mixing other gases for power conversion system of a SFR

    International Nuclear Information System (INIS)

    Jeong, Woo Seok; Lee, Jeong Ik; Jeong, Yong Hoon

    2011-01-01

    Highlights: → S-CO 2 cycle could be enhanced by shifting the critical point of working fluids using gas mixture. → In-house cycle code was developed to analyze supercritical Brayton cycles with gas mixture. → Gas mixture candidates were selected through a screening process: CO 2 mixing with N 2 , O 2 , He, and Ar. → CO 2 -He binary mixture shows the highest cycle efficiency increase. → Lowering the critical temperature and critical pressure of the coolant has a positive effect on the total cycle efficiency. - Abstract: A sodium-cooled fast reactor (SFR) is one of the strongest candidates for the next generation nuclear reactor. However, the conventional design of a SFR concept with an indirect Rankine cycle is subjected to a possible sodium-water reaction. To prevent any hazards from sodium-water reaction, a SFR with the Brayton cycle using Supercritical Carbon dioxide (S-CO 2 ) as the working fluid can be an alternative approach to improve the current SFR design. However, the S-CO 2 Brayton cycle is more sensitive to the critical point of working fluids than other Brayton cycles. This is because compressor work is significantly decreased slightly above the critical point due to high density of CO 2 near the boundary between the supercritical state and the subcritical state. For this reason, the minimum temperature and pressure of cycle are just above the CO 2 critical point. In other words, the critical point acts as a limitation of the lowest operating condition of the cycle. In general, lowering the rejection temperature of a thermodynamic cycle can increase the efficiency. Therefore, changing the critical point of CO 2 can result in an improvement of the total cycle efficiency with the same cycle layout. A small amount of other gases can be added in order to change the critical point of CO 2 . The direction and range of the critical point variation of CO 2 depends on the mixed component and its amount. Several gases that show chemical stability with

  15. Enhanced arrangement for recuperators in supercritical CO{sub 2} Brayton power cycle for energy conversion in fusion reactors

    Energy Technology Data Exchange (ETDEWEB)

    Serrano, I.P.; Linares, J.I., E-mail: linares@dim.icai.upcomillas.es; Cantizano, A.; Moratilla, B.Y.

    2014-10-15

    Highlights: •We propose an enhanced power conversion system layout for a Model C fusion reactor. •Proposed layout is based on a modified recompression supercritical CO{sub 2} Brayton cycle. •New arrangement in recuperators regards to classical cycle is used. •High efficiency is achieved, comparable with the best obtained in complex solutions. -- Abstract: A domestic research program called TECNO{sub F}US was launched in Spain in 2009 to support technological developments related to a dual coolant breeding blanket concept for fusion reactors. This concept of blanket uses Helium (300 °C/400 °C) to cool part of it and a liquid metal (480 °C/700 °C) to cool the rest; it also includes high temperature (700 °C/800 °C) and medium temperature (566 °C/700 °C) Helium cooling circuits for divertor. This paper proposes a new layout of the classical recompression supercritical CO{sub 2} Brayton cycle which replaces one of the recuperators (the one with the highest temperature) by another which by-passes the low temperature blanket source. This arrangement allows reaching high turbine inlet temperatures (around 600 °C) with medium pressures (around 225 bar) and achieving high cycle efficiencies (close to 46.5%). So, the proposed cycle reveals as a promising design because it integrates all the available thermal sources in a compact layout achieving high efficiencies with the usual parameters prescribed in classical recompression supercritical CO{sub 2} Brayton cycles.

  16. Optimization of advanced high-temperature Brayton cycles with multiple reheat stages

    International Nuclear Information System (INIS)

    Haihua Zhao; Per F Peterson

    2005-01-01

    Full text of publication follows: This paper presents an overview and a few point designs for multiple-reheat Brayton cycle power conversion systems using high temperature molten salts (or liquid metals). All designs are derived from the General Atomics GT-MHR power conversion unit (PCU). The GT-MHR PCU is currently the only closed helium cycle system that has undergone detailed engineering design analysis, and that has turbomachinery which is sufficiently large to extrapolate to a >1000 MW(e) multiple reheat gas cycle power conversion system. Analysis shows that, with relatively small engineering modifications, multiple GT-MHR PCU's can be connected together to create a power conversion system in the >1000 MW(e) class. The resulting power conversion system is quite compact, and results in what is likely the minimum gas duct volume possible for a multiple-reheat system. To realize this, compact offset fin plate type liquid-to-gas heat exchangers (power densities from 10 to 120 MW/m 3 ) are needed. Both metal and non-metal heat exchangers are being investigated for high-temperature, gas-cooled reactors for temperatures to 1000 deg. C. Recent high temperature heat exchanger studies for nuclear hydrogen production has suggested that carbon-coated composite materials such as liquid silicon infiltrated chopped fiber carbon-carbon preformed material potentially could be used to fabricate plate fin heat exchangers with reasonable price. Different fluids such as helium, nitrogen and helium mixture, and supercritical CO 2 are compared for these multiple reheat Brayton cycles. Nitrogen and helium mixture cycle need about 40% more total PCU volume than helium cycle while keeping the same net cycle efficiency. Supercritical CO 2 needs very high pressure to optimize. Due to relatively detailed design for components such as heat exchangers, turbomachinery, and duct system, relatively accurate total pressure loss can be obtained, which results in more credible net efficiency

  17. Radiation dose reduction in CT-guided periradicular injections in lumbar spine: Feasibility of a new institutional protocol for improved patient safety

    Directory of Open Access Journals (Sweden)

    Artner Juraj

    2012-08-01

    Full Text Available Abstract Background Image guided spinal injections are successfully used in the management of low back pain and sciatica. The main benefit of CT-guided injections is the safe, fast and precise needle placement, but the radiation exposure remains a serious concern. The purpose of the study was to test a new institutional low-dose protocol for CT-guided periradicular injections in lumbar spine to reduce radiation exposure while increasing accuracy and safety for the patients. Methods We performed a retrospective analysis of a prospective database during a 4-month period (Oct-Dec 2011 at a German University hospital using a newly established low-dose-CT-protocol for periradicular injections in patients suffering from lumbar disc herniation and nerve root entrapment. Inclusion criteria were acute or chronic nerve root irritation due to lumbar disc hernia, age over 18, compliance and informed consent. Excluded were patients suffering from severe obesity (BMI > 30, coagulopathy, allergy to injected substances, infection and non-compliant patients. Outcome parameters consisted of the measured dose length product (mGycm2, the amount of scans, age, gender, BMI and the peri-interventional complications. The results were compared to 50 patients, treated in the standard-interventional CT-protocol for spinal injections, performed in June-Oct 2011, who met the above mentioned inclusion criteria. Results A total amount of 100 patients were enrolled in the study. A significant radiation dose reduction (average 85.31% was achieved using the institutional low-dose protocol compared to standard intervention mode in CT-guided periradicular injections in lumbar spine. Using the low-dose protocol did not increase the complications rate in the analyzed cohort. Conclusions Low-dose-CT-protocols for lumbar perineural injections significantly reduce the exposure to radiation of non-obese patients without an increase of complications. This increases long-time patient

  18. Performance Optimization of a Solar-Driven Multi-Step Irreversible Brayton Cycle Based on a Multi-Objective Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Ahmadi Mohammad Hosein

    2016-01-01

    Full Text Available An applicable approach for a multi-step regenerative irreversible Brayton cycle on the basis of thermodynamics and optimization of thermal efficiency and normalized output power is presented in this work. In the present study, thermodynamic analysis and a NSGA II algorithm are coupled to determine the optimum values of thermal efficiency and normalized power output for a Brayton cycle system. Moreover, three well-known decision-making methods are employed to indicate definite answers from the outputs gained from the aforementioned approach. Finally, with the aim of error analysis, the values of the average and maximum error of the results are also calculated.

  19. A review of test results on solar thermal power modules with dish-mounted Stirling and Brayton cycle engines

    Science.gov (United States)

    Jaffe, Leonard D.

    1988-01-01

    This paper presents results of development tests of various solar thermal parabolic dish modules and assemblies that used dish-mounted Brayton or Stirling cycle engines for production of electric power. These tests indicate that early modules achieve net efficiencies up to 29 percent in converting sunlight to electricity, as delivered to the grid. Various equipment deficiencies were observed and a number of malfunctions occurred. The performance measurements, as well as the malfunctions and other test experience, provided information that should be of value in developing systems with improved performance and reduced maintenance.

  20. The efficiency of an open-cavity tubular solar receiver for a small-scale solar thermal Brayton cycle

    International Nuclear Information System (INIS)

    Le Roux, W.G.; Bello-Ochende, T.; Meyer, J.P.

    2014-01-01

    Highlights: • Results show efficiencies of a low-cost stainless steel tubular cavity receiver. • Optimum ratio of 0.0035 is found for receiver aperture area to concentrator area. • Smaller receiver tube and higher mass flow rate increase receiver efficiency. • Larger tube and smaller mass flow rate increase second law efficiency. • Large-tube receiver performs better in the small-scale solar thermal Brayton cycle. - Abstract: The first law and second law efficiencies are determined for a stainless steel closed-tube open rectangular cavity solar receiver. It is to be used in a small-scale solar thermal Brayton cycle using a micro-turbine with low compressor pressure ratios. There are many different variables at play to model the air temperature increase of the air running through such a receiver. These variables include concentrator shape, concentrator diameter, concentrator rim angle, concentrator reflectivity, concentrator optical error, solar tracking error, receiver aperture area, receiver material, effect of wind, receiver tube diameter, inlet temperature and mass flow rate through the receiver. All these variables are considered in this paper. The Brayton cycle requires very high receiver surface temperatures in order to be successful. These high temperatures, however, have many disadvantages in terms of heat loss from the receiver, especially radiation heat loss. With the help of ray-tracing software, SolTrace, and receiver modelling techniques, an optimum receiver-to-concentrator-area ratio of A′ ≈ 0.0035 was found for a concentrator with 45° rim angle, 10 mrad optical error and 1° tracking error. A method to determine the temperature profile and net heat transfer rate along the length of the receiver tube is presented. Receiver efficiencies are shown in terms of mass flow rate, receiver tube diameter, pressure drop, maximum receiver surface temperature and inlet temperature of the working fluid. For a 4.8 m diameter parabolic dish, the

  1. A review of test results on solar thermal power modules with dish-mounted Stirling and Brayton cycle engines

    Science.gov (United States)

    Jaffe, Leonard D.

    1988-11-01

    This paper presents results of development tests of various solar thermal parabolic dish modules and assemblies that used dish-mounted Brayton or Stirling cycle engines for production of electric power. These tests indicate that early modules achieve net efficiencies up to 29 percent in converting sunlight to electricity, as delivered to the grid. Various equipment deficiencies were observed and a number of malfunctions occurred. The performance measurements, as well as the malfunctions and other test experience, provided information that should be of value in developing systems with improved performance and reduced maintenance.

  2. Properties of noble gases and binary mixtures for closed Brayton Cycle applications

    International Nuclear Information System (INIS)

    Tournier, Jean-Michel P.; El-Genk, Mohamed S.

    2008-01-01

    A review is conducted of the properties of the noble gases, helium, neon, argon, krypton and xenon, and their binary mixtures at pressures from 0.1 to 20 MPa and temperatures up to 1400 K. An extensive database of experimental measurements is compiled and used to develop semi-empirical properties correlations. The correlations accurately account for the effects of pressure and temperature on the thermodynamic and transport properties of these gases for potential uses in space (∼2 MPa and up to 1400 K) and terrestrial (∼7.0 MPa and up to 1200 K) applications of Closed Brayton Cycle (CBC). The developed correlations are based on the Chapman-Enskog kinetic theory for dilute gases, and on the application of the law of corresponding states to account for the dependence of properties on pressure. The correlations use the critical temperature and density of the gases as scaling parameters, and their predictions are compared with the compiled database. At temperatures ≥400 K and pressures ≤2 MPa in CBC space power systems, He and Ne, and the binary mixtures of He-Xe and He-Kr with molecular weights ≤40 g/mole behave essentially like a perfect gas, and the error of neglecting the effect of pressure on their compressibility factor, specific heats and transport properties is ≤1%. At a typical operating pressure of 7.0 MPa and up to 1200 K in terrestrial CBC power plants, neglecting the effect of pressure can result in ∼4% error in the properties of noble gases and the binary mixtures of He-Xe and He-Kr with molecular weights ≤40 g/mole, and as much as 20% error for pure argon. Therefore, when operating at pressures >2.0 MPa and/or using noble gases or binary mixtures with molecular weights > 40 g/mole, the present correlations should be used to accurately predict the thermodynamic and transport properties

  3. Modeling the small-scale dish-mounted solar thermal Brayton cycle

    Science.gov (United States)

    Le Roux, Willem G.; Meyer, Josua P.

    2016-05-01

    The small-scale dish-mounted solar thermal Brayton cycle (STBC) makes use of a sun-tracking dish reflector, solar receiver, recuperator and micro-turbine to generate power in the range of 1-20 kW. The modeling of such a system, using a turbocharger as micro-turbine, is required so that optimisation and further development of an experimental setup can be done. As a validation, an analytical model of the small-scale STBC in Matlab, where the net power output is determined from an exergy analysis, is compared with Flownex, an integrated systems CFD code. A 4.8 m diameter parabolic dish with open-cavity tubular receiver and plate-type counterflow recuperator is considered, based on previous work. A dish optical error of 10 mrad, a tracking error of 1° and a receiver aperture area of 0.25 m × 0.25 m are considered. Since the recuperator operates at a very high average temperature, the recuperator is modeled using an updated ɛ-NTU method which takes heat loss to the environment into consideration. Compressor and turbine maps from standard off-the-shelf Garrett turbochargers are used. The results show that for the calculation of the steady-state temperatures and pressures, there is good comparison between the Matlab and Flownex results (within 8%) except for the recuperator outlet temperature, which is due to the use of different ɛ-NTU methods. With the use of Matlab and Flownex, it is shown that the small-scale open STBC with an existing off-the-shelf turbocharger could generate a positive net power output with solar-to-mechanical efficiency of up to 12%, with much room for improvement.

  4. Feasibility and Safety of Vascular Closure Devices in an Antegrade Approach to Either the Common Femoral Artery or the Superficial Femoral Artery

    International Nuclear Information System (INIS)

    Gutzeit, Andreas; Schie, Bram van; Schoch, Eric; Hergan, Klaus; Graf, Nicole; Binkert, Christoph A.

    2012-01-01

    Introduction: The purpose of the present study was to analyze complications following antegrade puncture of the common femoral artery (CFA) and the superficial femoral artery (SFA) using vascular closure systems (VCS). Methods: A single-center, retrospective study was performed after obtaining approval from the institutional review board and informed consent from all patients. At our center, the CFA or SFA are used for arterial access. All patients were evaluated clinically on the same day. If there was any suspicion of an access site problem, Duplex ultrasound was performed. Results: Access location was the CFA in 50 patients and the SFA in 130 patients. The sheath size ranged from 4F to 10F. Two patients had to be excluded because of lack of follow-up. Successful hemostasis was achieved in 162 of 178 cases (91 %). The following complications were observed in 16 patients (8.9 %): 4 pseudoaneurysms (2.2 %), 11 hematomas (6.2 %), and 1 vascular occlusion (0.5 %). The two pseudoaneurysms healed spontaneously, in one case an ultrasound-guided thrombin injection was performed, and one aneurysm was compressed manually. No further medical therapy was needed for the hematomas. The one vascular occlusion was treated immediately with angioplasty using a contralateral approach. No significant difference was noted between the CFA and the SFA group with respect to complications (p = 1.000). Conclusions: The use of closure devices for an antegrade approach up to 10F is feasible and safe. No differences in low complication rates were observed between CFA and SFA.

  5. Feasibility and Safety of Vascular Closure Devices in an Antegrade Approach to Either the Common Femoral Artery or the Superficial Femoral Artery

    Energy Technology Data Exchange (ETDEWEB)

    Gutzeit, Andreas, E-mail: andreas.gutzeit@ksw.ch; Schie, Bram van, E-mail: Bram.vanschie@hotmail.com; Schoch, Eric, E-mail: eric.schoch@ksw.ch [Cantonal Hospital Winterthur, Department of Radiology (Switzerland); Hergan, Klaus, E-mail: k.hergan@salk.at [Paracelsus Medical University Salzburg, Department of Radiology (Austria); Graf, Nicole, E-mail: graf@biostatistics.ch; Binkert, Christoph A., E-mail: christoph.binkert@ksw.ch [Cantonal Hospital Winterthur, Department of Radiology (Switzerland)

    2012-10-15

    Introduction: The purpose of the present study was to analyze complications following antegrade puncture of the common femoral artery (CFA) and the superficial femoral artery (SFA) using vascular closure systems (VCS). Methods: A single-center, retrospective study was performed after obtaining approval from the institutional review board and informed consent from all patients. At our center, the CFA or SFA are used for arterial access. All patients were evaluated clinically on the same day. If there was any suspicion of an access site problem, Duplex ultrasound was performed. Results: Access location was the CFA in 50 patients and the SFA in 130 patients. The sheath size ranged from 4F to 10F. Two patients had to be excluded because of lack of follow-up. Successful hemostasis was achieved in 162 of 178 cases (91 %). The following complications were observed in 16 patients (8.9 %): 4 pseudoaneurysms (2.2 %), 11 hematomas (6.2 %), and 1 vascular occlusion (0.5 %). The two pseudoaneurysms healed spontaneously, in one case an ultrasound-guided thrombin injection was performed, and one aneurysm was compressed manually. No further medical therapy was needed for the hematomas. The one vascular occlusion was treated immediately with angioplasty using a contralateral approach. No significant difference was noted between the CFA and the SFA group with respect to complications (p = 1.000). Conclusions: The use of closure devices for an antegrade approach up to 10F is feasible and safe. No differences in low complication rates were observed between CFA and SFA.

  6. The Safety and Feasibility of Three-Dimensional Visualization Technology Assisted Right Posterior Lobe Allied with Part of V and VIII Sectionectomy for Right Hepatic Malignancy Therapy.

    Science.gov (United States)

    Hu, Min; Hu, Haoyu; Cai, Wei; Mo, Zhikang; Xiang, Nan; Yang, Jian; Fang, Chihua

    2018-05-01

    Hepatectomy is the optimal method for liver cancer; the virtual liver resection based on three-dimensional visualization technology (3-DVT) could provide better preoperative strategy for surgeon. We aim to introduce right posterior lobe allied with part of V and VIII sectionectomy assisted by 3-DVT as a promising treatment for massive or multiple right hepatic malignancies to retain maximum residual liver volume on the basis of R0 resection. Among 126 consecutive patients who underwent hepatectomy, 9 (7%) underwent right posterior lobe allied with part of V and VIII sectionectomy. 21 (17%) underwent right hemihepatectomy (RH). The virtual RH was performed with 3-DVT, which provided better observation of spatial position relationship between tumor and vessels, and the more accurate estimation of the remnant liver volume. If remnant liver volume was right posterior lobe allied with part of V and VIII sectionectomy should be undergone. Then, the precut line ought to be planned on the basis of protecting the portal branch of subsegment 5 and 8. The postoperative outcome of patients was compared before and after propensity score matching. Nine patients meeting the eligibility criteria received right posterior lobe allied with part of V and VIII sectionectomy. The variables, including the overall mean operation time, blood transfusion, operation length, liver function, and postoperative complications, were similar between two groups before and after propensity matching. The postoperative first, third, fifth, and seventh days mean value of aspartate aminotransferase (AST), alanine aminotransferase (ALT), albumin (ALB), and total bilirubin had no significant difference compared with preoperative value. One patient in each group had recurrence six months after surgery. Right posterior lobe allied with part of V and VIII sectionectomy based on 3-DVT is safe and feasible surgery way, and can be a very promising method in massive or multiple right hepatic malignancy therapy.

  7. Ensuring safety of people in case of severe floods: feasibility and relevance of vertical evacuation strategies in high population density areas

    Directory of Open Access Journals (Sweden)

    Pannier Rodolphe

    2016-01-01

    Full Text Available When a major flooding event is expected the authorities in charge of the crisis management often consider bringing people to safety by making them leaving temporarily the threatened area before the onset of the flood. This strategy is called “horizontal evacuation”. It has to be distinguished from “vertical evacuation”, which means that people reach a shelter above the wtaer level within the flood area. Vertical evacuation is often the spontaneousbehaviourof people who are surprised by the flood and are trying to reach a tree, a floor upstairs, a roof of a building etc. in order to get away from the rising water. But vertical evacuation could also be consideredas an alternative strategy to horizontal evacuation when moving outside the flood area is neither a faisible nor a relevant option, for example in high-population density areas. In order to be a credible alternative to horizontal evacuation, vertical evacuation has to be carefully planned. This paper aims to explain why horizontal evacuation is not always a suitable option in case of major flood and to explore under what conditions vertical evacuation can be a relevantalternative solution to horizontal evacuation. It also adresses some general recommendations about how to prepare a vertical evacuation strategy..

  8. Safety and feasibility audit of a home-based drug-transitioning approach for patients with pulmonary arterial hypertension: an observational study.

    Science.gov (United States)

    Dawson, A; Reddecliffe, S; Coghlan, C; Schreiber, B E; Coghlan, J G

    2018-04-01

    Newer endothelin receptor antagonists (ERAs) used to treat patients with pulmonary arterial hypertension (PAH) are associated with fewer drug-drug interactions than bosentan and require less monitoring. This, combined with a pharmacokinetic basis for improved efficacy, means there may be a clinical rationale for changing therapies. However, this can be challenging and few data on its safety in patients with PAH are available. At the Royal Free Hospital in London, UK, home-based medication transitioning has been standard practice since 2009 to avoid unnecessary hospital visits for patients, unless there is a clinical imperative. In this audit of standard practice we evaluated the consequences of adopting such a strategy when transitioning PAH patients between ERA therapies. Using a Clinical Nurse Specialist-led, home-based transitioning strategy, 92 patients with PAH were transitioned from bosentan to macitentan or ambrisentan. Observational data were analysed retrospectively. The majority of patients were female with PAH associated with connective tissue disease and their ERA was changed in the hope of improving efficacy. The process was well tolerated with no adverse events associated with the process. Seventeen patients died during the study (macitentan, n = 5; ambrisentan, n = 12). None of the deaths was considered related to ERA treatment. The majority of patients remained clinically stable, based on WHO functional class and exercise capacity. An established home-based transitioning strategy can be adopted safely for patients with PAH changing ERA therapies. Most patients remained stable and the therapy change was well tolerated.

  9. Early in-flight detection of SO2 via Differential Optical Absorption Spectroscopy: a feasible aviation safety measure to prevent potential encounters with volcanic plumes

    Directory of Open Access Journals (Sweden)

    U. Platt

    2011-09-01

    Full Text Available Volcanic ash constitutes a risk to aviation, mainly due to its ability to cause jet engines to fail. Other risks include the possibility of abrasion of windshields and potentially serious damage to avionic systems. These hazards have been widely recognized since the early 1980s, when volcanic ash provoked several incidents of engine failure in commercial aircraft. In addition to volcanic ash, volcanic gases also pose a threat. Prolonged and/or cumulative exposure to sulphur dioxide (SO2 or sulphuric acid (H2SO4 aerosols potentially affects e.g. windows, air frame and may cause permanent damage to engines. SO2 receives most attention among the gas species commonly found in volcanic plumes because its presence above the lower troposphere is a clear proxy for a volcanic cloud and indicates that fine ash could also be present. Up to now, remote sensing of SO2 via Differential Optical Absorption Spectroscopy (DOAS in the ultraviolet spectral region has been used to measure volcanic clouds from ground based, airborne and satellite platforms. Attention has been given to volcanic emission strength, chemistry inside volcanic clouds and measurement procedures were adapted accordingly. Here we present a set of experimental and model results, highlighting the feasibility of DOAS to be used as an airborne early detection system of SO2 in two spatial dimensions. In order to prove our new concept, simultaneous airborne and ground-based measurements of the plume of Popocatépetl volcano, Mexico, were conducted in April 2010. The plume extended at an altitude around 5250 m above sea level and was approached and traversed at the same altitude with several forward looking DOAS systems aboard an airplane. These DOAS systems measured SO2 in the flight direction and at ±40 mrad (2.3° angles relative to it in both, horizontal and vertical directions. The approaches started at up to 25 km distance to the plume and SO2 was measured at all times well above the

  10. Safety and Feasibility of Lin- Cells Administration to ALS Patients: A Novel View on Humoral Factors and miRNA Profiles

    Directory of Open Access Journals (Sweden)

    Anna Sobuś

    2018-04-01

    -negative early hematopoietic cells injected intrathecally may be a safe and feasible source of material for transplantations to the central nervous system (CNS environment aimed at anti-inflammatory support provision for ALS adjuvant treatment strategies. Further research is needed to evaluate whether the observed effects could significantly influence the ALS progression.

  11. Early in-flight detection of SO2 via Differential Optical Absorption Spectroscopy: A feasible aviation safety measure to prevent potential encounters with volcanic plumes

    Science.gov (United States)

    Vogel, L.; Galle, B.; Kern, C.; Delgado, Granados H.; Conde, V.; Norman, P.; Arellano, S.; Landgren, O.; Lubcke, P.; Alvarez, Nieves J.M.; Cardenas, Gonzales L.; Platt, U.

    2011-01-01

    Volcanic ash constitutes a risk to aviation, mainly due to its ability to cause jet engines to fail. Other risks include the possibility of abrasion of windshields and potentially serious damage to avionic systems. These hazards have been widely recognized 5 since the early 1980s, when volcanic ash provoked several incidents of engine failure in commercial aircraft. In addition to volcanic ash, volcanic gases also pose a threat. Prolonged and/or cumulative exposure to sulphur dioxide (SO2) or sulphuric acid (H2SO4) aerosols potentially affects e.g. windows, air frame and may cause permanent damage to engines. SO2 receives most attention among the gas species commonly found in 10 volcanic plumes because its presence above the lower troposphere is a clear proxy for a volcanic cloud and indicates that fine ash could also be present. Up to now, remote sensing of SO2 via Differential Optical Absorption Spectroscopy (DOAS) in the ultraviolet spectral region has been used to measure volcanic clouds from ground based, airborne and satellite platforms. Attention has been given to vol- 15 canic emission strength, chemistry inside volcanic clouds and measurement procedures were adapted accordingly. Here we present a set of experimental and model results, highlighting the feasibility of DOAS to be used as an airborne early detection system of SO2 in two spatial dimensions. In order to prove our new concept, simultaneous airborne and ground-based measurements of the plume of Popocatepetl volcano, Mexico, were conducted in April 2010. The plume extended at an altitude around 5250 m above sea level and was approached and traversed at the same altitude with several forward looking DOAS systems aboard an airplane. These DOAS systems measured SO2 in the flight direction and at ±40 mrad (2.3◦) angles relative to it in both, horizontal and vertical directions. The approaches started at up to 25 km distance to 25 the plume and SO2 was measured at all times well above the detection

  12. Safety and Feasibility of Lin- Cells Administration to ALS Patients: A Novel View on Humoral Factors and miRNA Profiles.

    Science.gov (United States)

    Sobuś, Anna; Baumert, Bartłomiej; Litwińska, Zofia; Gołąb-Janowska, Monika; Stępniewski, Jacek; Kotowski, Maciej; Pius-Sadowska, Ewa; Kawa, Miłosz P; Gródecka-Szwajkiewicz, Dorota; Peregud-Pogorzelski, Jarosław; Dulak, Józef; Nowacki, Przemysław; Machaliński, Bogusław

    2018-04-27

    hematopoietic cells injected intrathecally may be a safe and feasible source of material for transplantations to the central nervous system (CNS) environment aimed at anti-inflammatory support provision for ALS adjuvant treatment strategies. Further research is needed to evaluate whether the observed effects could significantly influence the ALS progression.

  13. Development of a Supercritical Carbon Dioxide Brayton Cycle: Improving VHTR Efficiency and Testing Material Compatibility - Final Report

    International Nuclear Information System (INIS)

    Chang H. Oh

    2006-01-01

    Generation IV reactors will need to be intrinsically safe, having a proliferation-resistant fuel cycle and several advantages relative to existing light water reactor (LWR). They, however, must still overcome certain technical issues and the cost barrier before it can be built in the U.S. The establishment of a nuclear power cost goal of 3.3 cents/kWh is desirable in order to compete with fossil combined-cycle, gas turbine power generation. This goal requires approximately a 30 percent reduction in power cost for state-of-the-art nuclear plants. It has been demonstrated that this large cost differential can be overcome only by technology improvements that lead to a combination of better efficiency and more compatible reactor materials. The objectives of this research are (1) to develop a supercritical carbon dioxide Brayton cycle in the secondary power conversion side that can be applied to the Very-High-Temperature Gas-Cooled Reactor (VHTR), (2) to improve the plant net efficiency by using the carbon dioxide Brayton cycle, and (3) to test material compatibility at high temperatures and pressures. The reduced volumetric flow rate of carbon dioxide due to higher density compared to helium will reduce compression work, which eventually increase plant net efficiency

  14. Potential Improvements of Supercritical Recompression CO2 Brayton Cycle Coupled with KALIMER-600 by Modifying Critical Point of CO2

    International Nuclear Information System (INIS)

    Jeong, Woo Seok; Lee, Jeong Ik; Jeong, Yong Hoon; No, Hee Cheon

    2010-01-01

    Most of the existing designs of a Sodium cooled Fast Reactor (SFR) have a Rankine cycle as an electric power generation cycle. This has the risk of a sodium water reaction. To prevent any hazards from a sodium water reaction, an indirect Brayton cycle using Supercritical Carbon dioxide (S-CO 2 ) as the working fluids for a SFR is an alternative approach to improve the current SFR design. The supercritical Brayton cycle is defined as a cycle with operating conditions above the critical point and the main compressor inlet condition located slightly above the critical point of working fluid. This is because the main advantage of the cycle comes from significantly decreased compressor work just above the critical point due to high density near boundary between supercritical state and subcritical state. For this reason, the minimum temperature and pressure of cycle are just above the CO 2 critical point. In other words, the critical point acts as a limitation of the lowest operating condition of the cycle. In general, lowering the minimum temperature of a thermodynamic cycle can increase the efficiency and the minimum temperature can be decreased by shifting the critical point of CO 2 as mixed with other gases. In this paper, potential enhancement of S-CO 2 cycle coupled with KALIMER-600, which has been developed at KAERI, was investigated using a developed cycle code with a gas mixture property program

  15. Effect of geometrical shape of the working substance Gadolinium on the performance of a regenerative magnetic Brayton refrigeration cycle

    International Nuclear Information System (INIS)

    Diguet, Gildas; Lin, Guoxing; Chen, Jincan

    2013-01-01

    Based on Mean Field Theory (MFT), the entropy of magnetic material Gadolinium (Gd), which is a function of the local magnetic field and temperature, is calculated and analyzed. This local magnetic field is the sum of the applied field H 0 plus the exchange field H W =λM and the demagnetizing field H d =−NM, where the demagnetizing factor N depends on the shape of magnetic materials. Hereby, the impacts of the demagnetizing factor N on the magnetic entropy, magnetic entropy change and main thermodynamics performance of a regenerative magnetic Brayton refrigeration cycle using Gd as the working substance are investigated and evaluated in detail. The results obtained underline the importance of the shape of the working substance used in magnetic refrigerators for room-temperature application; elongated materials provide better thermodynamics performance such as higher COP and net heat absorption. It is pointed out that for low external fields, the magnetic refrigerator ceased to be functional if flat materials were used. - Highlights: ► Gd entropy is calculated as a function of temperature and internal magnetic field. ► Magnetic Brayton cycle properties generally depend on the demagnetizing factor. ► Redundant heat transfer is highly sensitive to the demagnetizing factor. ► The net cooling quantity is highly sensitive to the demagnetizing factor. ► Coefficient of performance is dependant to the magnetic material shape.

  16. Thermal performance analysis of Brayton cycle with waste heat recovery boiler for diesel engines of offshore oil production facilities

    International Nuclear Information System (INIS)

    Liu, Xianglong; Gong, Guangcai; Wu, Yi; Li, Hangxin

    2016-01-01

    Highlights: • Comparison of Brayton cycle with WHRB adopted in diesel engines with and without fans by thermal performance. • Waste heat recovery technology for FPSO. • The thermoeconomic analysis for the heat recovery for FPSO. - Abstract: This paper presents the theoretical analysis and on-site testing on the thermal performance of the waste heat recovery system for offshore oil production facilities, including the components of diesel engines, thermal boilers and waste heat boilers. We use the ideal air standard Brayton cycle to analyse the thermal performance. In comparison with the traditional design, the fans at the engine outlet of the waste heat recovery boiler is removed due to the limited space of the offshore platform. The cases with fan and without fan are compared in terms of thermal dynamics performance, energy efficiency and thermo-economic index of the system. The results show that the application of the WHRB increases the energy efficiency of the whole system, but increases the flow resistance in the duct. It is proved that as the waste heat recovery boiler takes the place of the thermal boiler, the energy efficiency of whole system without fan is slightly reduced but heat recovery efficiency is improved. This research provides an important guidance to improve the waste heat recovery for offshore oil production facilities.

  17. Prospective evaluation of the feasibility, safety, and efficacy of Cocoon Duct Occluder for transcatheter closure of large patent ductus arteriosus: A single-center study with short- and medium-term follow-up results

    Science.gov (United States)

    Sinha, Santosh Kumar; Razi, Mahmadula; Pandey, Rama Niwas; Kumar, Prakash; Krishna, Vinay; Jha, Mukesh Jitendra; Mishra, Vikas; Asif, Mohammad; Abdali, Nasar; Tewari, Pradyot; Thakur, Ramesh; Pandey, Umeshwar; Varma, Chandra Mohan

    2017-01-01

    Objective: To evaluate the feasibility, safety, and efficacy of a novel Cocoon Duct Occluder device for the transcatheter closure (TCC) of large patent ductus arteriosus (PDA). Methods: In this prospective, non-randomized study, consecutive patients with large PDA (narrowest diameter: ≥3.5/4.0 mm in symptomatic/asymptomatic patients, respectively), who underwent TCC with Cocoon Duct Occluder at our institute between November, 2012 and June, 2016 were examined. TCC was performed using the standard technique, and devices were antegradely delivered via 6–10F delivery sheaths. Device embolization, residual shunt, hemolysis, left pulmonary artery (LPA) stenosis, procedural and fluoroscopy time, and mortality were assessed. Patients were followed-up by transthoracic echocardiography with color Doppler imaging at 24 h (D1), 1 month (D30), and 6 months (D180) after implantation. Results: A total of 57 patients (age: 11.7±2.8 years; weight: 22.3±3.5 kg) were enrolled. The mean narrowest diameter was 7.4±0.7 mm. The PDA closure was successfully performed in each patient. Fluoroscopy and procedural time was 6.7±3.2 min and 23.9±2.7 min, respectively. Postprocedural angiography revealed that 49 (85.9%) patients had immediate and complete closure, whereas 8 (14.1%) had residual shunt. Color Doppler imaging at D1 revealed complete closure in 52 (91.3%) patients. At D30, complete closure was reported in all patients and was maintained at D180. Hemolysis, embolization, obstruction of LPA or descending aorta, and death were not reported till D180. Conclusion: TCC using Cocoon Duct Occluder is feasible, safe, and effective in the management of patients with large PDA, with excellent results on short- and medium-term follow-up. PMID:29145233

  18. A randomized control trial to establish the feasibility and safety of rapamycin treatment in an older human cohort: Immunological, physical performance, and cognitive effects.

    Science.gov (United States)

    Kraig, Ellen; Linehan, Leslie A; Liang, Hanyu; Romo, Terry Q; Liu, Qianqian; Wu, Yubo; Benavides, Adriana D; Curiel, Tyler J; Javors, Martin A; Musi, Nicolas; Chiodo, Laura; Koek, Wouter; Gelfond, Jonathan A L; Kellogg, Dean L

    2018-05-01

    Inhibition of the mechanistic target of rapamycin (mTOR) pathway by rapamycin (RAPA), an FDA-approved immunosuppressive drug used as a clinical therapy to prevent solid organ allograft rejection, enhances longevity in mice. Importantly, RAPA was efficacious even when initiated in relatively old animals, suggesting that mTOR inhibition could potentially slow the progression of aging-associated pathologies in older humans (Harrison et al., 2009; Miller et al., 2011). However, the safety and tolerability of RAPA in older human subjects have not yet been demonstrated. Towards this end, we undertook a placebo-controlled pilot study in 25 generally healthy older adults (aged 70-95 years); subjects were randomized to receive either 1 mg RAPA or placebo daily. Although three subjects withdrew, 11 RAPA and 14 controls completed at least 8 weeks of treatment and were included in the analysis. We monitored for changes that would indicate detrimental effects of RAPA treatment on metabolism, including both standard clinical laboratory assays (CBC, CMP, HbA1c) and oral glucose tolerance tests (OGTTs). We also monitored parameters typically associated with aging that could potentially be modified by RAPA; these included cognitive function which was assessed by three different tools: Executive Interview-25 (EXIT25); Saint Louis University Mental Status Exam (SLUMS); and Texas Assessment of Processing Speed (TAPS). In addition, physical performance was measured by handgrip strength and 40-foot timed walks. Lastly, changes in general parameters of healthy immune aging, including serum pro-inflammatory cytokine levels and blood cell subsets, were assessed. Five subjects reported potential adverse side effects; in the RAPA group, these were limited to facial rash (1 subject), stomatitis (1 subject) and gastrointestinal issues (2 subjects) whereas placebo treated subjects only reported stomatitis (1 subject). Although no other adverse events were reported, statistically

  19. Feasibility and safety of low-flow extracorporeal CO2 removal managed with a renal replacement platform to enhance lung-protective ventilation of patients with mild-to-moderate ARDS.

    Science.gov (United States)

    Schmidt, Matthieu; Jaber, Samir; Zogheib, Elie; Godet, Thomas; Capellier, Gilles; Combes, Alain

    2018-05-10

    Extracorporeal carbon-dioxide removal (ECCO 2 R) might allow ultraprotective mechanical ventilation with lower tidal volume (VT) (ventilator-induced lung injury. This study was undertaken to assess the feasibility and safety of ECCO 2 R managed with a renal replacement therapy (RRT) platform to enable very low tidal volume ventilation of patients with mild-to-moderate acute respiratory distress syndrome (ARDS). Twenty patients with mild (n = 8) or moderate (n = 12) ARDS were included. VT was gradually lowered from 6 to 5, 4.5, and 4 ml/kg, and PEEP adjusted to reach 23 ≤ P plat  ≤ 25 cmH 2 O. Standalone ECCO 2 R (no hemofilter associated with the RRT platform) was initiated when arterial PaCO 2 increased by > 20% from its initial value. Ventilation parameters (VT, respiratory rate, PEEP), respiratory system compliance, P plat and driving pressure, arterial blood gases, and ECCO 2 R-system operational characteristics were collected during at least 24 h of very low tidal volume ventilation. Complications, day-28 mortality, need for adjuvant therapies, and data on weaning off ECCO 2 R and mechanical ventilation were also recorded. While VT was reduced from 6 to 4 ml/kg and P plat kept ventilation with moderate increase in PaCO 2 in patients with mild-to-moderate ARDS. ClinicalTrials.gov, NCT02606240. Registered on 17 November 2015.

  20. Demonstration of the Safety and Feasibility of Robotically Assisted Percutaneous Coronary Intervention in Complex Coronary Lesions: Results of the CORA-PCI Study (Complex Robotically Assisted Percutaneous Coronary Intervention).

    Science.gov (United States)

    Mahmud, Ehtisham; Naghi, Jesse; Ang, Lawrence; Harrison, Jonathan; Behnamfar, Omid; Pourdjabbar, Ali; Reeves, Ryan; Patel, Mitul

    2017-07-10

    The aims of this study were to evaluate the feasibility and technical success of robotically assisted percutaneous coronary intervention (R-PCI) for the treatment of coronary artery disease (CAD) in clinical practice, especially in complex lesions, and to determine the safety and clinical success of R-PCI compared with manual percutaneous coronary intervention (M-PCI). R-PCI is safe and feasible for simple coronary lesions. The utility of R-PCI for complex coronary lesions is unknown. All consecutive PCI procedures performed robotically (study group) or manually (control group) over 18 months were included. R-PCI technical success, defined as the completion of the procedure robotically or with partial manual assistance and without a major adverse cardiovascular event, was determined. Procedures ineligible for R-PCI (i.e., atherectomy, planned 2-stent strategy for bifurcation lesion, chronic total occlusion requiring hybrid approach) were excluded for analysis from the M-PCI group. Clinical success, defined as completion of the PCI procedure without a major adverse cardiovascular event, procedure time, stent use, and fluoroscopy time were compared between groups. A total of 315 patients (mean age 67.7 ± 11.8 years; 78% men) underwent 334 PCI procedures (108 R-PCIs, 157 lesions, 78.3% type B2/C; 226 M-PCIs, 336 lesions, 68.8% type B2/C). Technical success with R-PCI was 91.7% (rate of manual assistance 11.1%, rate of manual conversion 7.4%, rate of major adverse cardiovascular events 0.93%). Clinical success (99.1% with R-PCI vs. 99.1% with M-PCI; p = 1.00), stent use (stents per procedure 1.59 ± 0.79 with R-PCI vs. 1.54 ± 0.75 with M-PCI; p = 0.73), and fluoroscopy time (18.2 ± 10.4 min with R-PCI vs. 19.2 ± 11.4 min with M-PCI; p = 0.39) were similar between the groups, although procedure time was longer in the R-PCI group (44:30 ± 26:04 min:s vs. 36:34 ± 23:03 min:s; p = 0.002). Propensity-matched analysis confirmed that procedure time was longer

  1. Optimum performance of the small scale open and direct solar thermal Brayton cycle at various environmental conditions and constraints

    Energy Technology Data Exchange (ETDEWEB)

    Le Roux, W.G.; Bello-Ochende, T.; Meyer, J.P. [Department of Mechanical and Aeronautical Engineering, University of Pretoria, (South Africa)

    2011-07-01

    The energy of the sun can be transformed into mechanical power through the use of concentrated solar power systems. The use of the Brayton cycle with recuperator has significant advantages but also raises issues such as pressure loss and low net power output which are mainly due to irreversibilities of heat transfer and fluid friction. The aim of this study is to optimize the system to generate maximum net power output. Thermodynamic and dynamic trajectory optimizations were performed on a dish concentrator and an off-the-shelf micro-turbine and the effects of wind, solar irradiance and other environmental conditions and constraints on the power output were analyzed. Results showed that the maximum power output is increased when wind decreases and irradiance increases; solar irradiance was found to have a more significant impact than wind. This study highlighted the factors which impact the power generation of concentrated solar power systems so that designers can take them into account.

  2. Hydrogen system (hydrogen fuels feasibility)

    International Nuclear Information System (INIS)

    Guarna, S.

    1991-07-01

    This feasibility study on the production and use of hydrogen fuels for industry and domestic purposes includes the following aspects: physical and chemical properties of hydrogen; production methods steam reforming of natural gas, hydrolysis of water; liquid and gaseous hydrogen transportation and storage (hydrogen-hydride technology); environmental impacts, safety and economics of hydrogen fuel cells for power generation and hydrogen automotive fuels; relevant international research programs

  3. NTRE extended life feasibility assessment

    Science.gov (United States)

    Results of a feasibility analysis of a long life, reusable nuclear thermal rocket engine are presented in text and graph form. Two engine/reactor concepts are addressed: the Particle Bed Reactor (PBR) design and the Commonwealth of Independent States (CIS) concept. Engine design, integration, reliability, and safety are addressed by various members of the NTRE team from Aerojet Propulsion Division, Energopool (Russia), and Babcock & Wilcox.

  4. Supercritical CO2 Brayton power cycles for DEMO (demonstration power plant) fusion reactor based on dual coolant lithium lead blanket

    International Nuclear Information System (INIS)

    Linares, José Ignacio; Cantizano, Alexis; Moratilla, Beatriz Yolanda; Martín-Palacios, Víctor; Batet, Lluis

    2016-01-01

    This paper presents an exploratory analysis of the suitability of supercritical CO 2 Brayton power cycles as alternative energy conversion systems for a future fusion reactor based on a DCLL (dual coolant lithium-lead) blanket, as prescribed by EUROfusion. The main issue dealt is the optimization of the integration of the different thermal sources with the power cycle in order to achieve the highest electricity production. The analysis includes the assessment of the pumping consumption in the heating and cooling loops, taking into account additional considerations as control issues and integration of thermal energy storage systems. An exergy analysis has been performed in order to understand the behavior of each layout. Up to ten scenarios have been analyzed assessing different locations for thermal sources heat exchangers. Neglecting the worst four scenarios, it is observed less than 2% of variation among the other six ones. One of the best six scenarios clearly stands out over the others due to the location of the thermal sources in a unique island, being this scenario compatible with the control criteria. In this proposal 34.6% of electric efficiency (before the self-consumptions of the reactor but including pumping consumptions and generator efficiency) is achieved. - Highlights: • Supercritical CO 2 Brayton cycles have been proposed for BoP of DCLL fusion reactor. • Integration of different available thermal sources has been analyzed considering ten scenarios. • Neglecting the four worst scenarios the electricity production varies less than 2%. • Control and energy storage integration issues have been considered in the analysis. • Discarding the vacuum vessel and joining the other sources in an island is proposed.

  5. Supercritical CO2 Brayton power cycles for DEMO fusion reactor based on Helium Cooled Lithium Lead blanket

    International Nuclear Information System (INIS)

    Linares, José Ignacio; Herranz, Luis Enrique; Fernández, Iván; Cantizano, Alexis; Moratilla, Beatriz Yolanda

    2015-01-01

    Fusion energy is one of the most promising solutions to the world energy supply. This paper presents an exploratory analysis of the suitability of supercritical CO 2 Brayton power cycles (S-CO 2 ) for low-temperature divertor fusion reactors cooled by helium (as defined by EFDA). Integration of three thermal sources (i.e., blanket, divertor and vacuum vessel) has been studied through proposing and analyzing a number of alternative layouts, achieving an improvement on power production higher than 5% over the baseline case, which entails to a gross efficiency (before self-consumptions) higher than 42%. In spite of this achievement, the assessment of power consumption for the circulating heat transfer fluids results in a penalty of 20% in the electricity production. Once the most suitable layout has been selected an optimization process has been conducted to adjust the key parameters to balance performance and size, achieving an electrical efficiency (electricity without taking into account auxiliary consumptions due to operation of the fusion reactor) higher than 33% and a reduction in overall size of heat exchangers of 1/3. Some relevant conclusions can be drawn from the present work: the potential of S-CO 2 cycles as suitable converters of thermal energy to power in fusion reactors; the significance of a suitable integration of thermal sources to maximize power output; the high penalty of pumping power; and the convenience of identifying the key components of the layout as a way to optimize the whole cycle performance. - Highlights: • Supercritical CO 2 Brayton cycles have been proposed for BoP of HCLL fusion reactor. • Low temperature sources have been successfully integrated with high temperature ones. • Optimization of thermal sources integration improves 5% the electricity production. • Assessment of pumping power with sources and sink loops results on 20% of gross power. • Matching of key parameters has conducted to 1/3 of reduction in heat

  6. Conceptual Design of S-CO{sub 2} Brayton Cycle Radial Turbomachinery for KAIST Micro Modular Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seongkuk; Kim, Seong Gu; Lee, Jekyoung; Lee, Jeong Ik [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2014-05-15

    KAIST proposed a new SMR design, which utilizes S-CO{sub 2} as the working fluid. It was named as KAIST MMR. Compared with existing SMR concepts, KAIST MMR has advantages of achieving smaller volume of power conversion unit (PCU) and containing the core and PCU in one vessel for the complete modularization. Authors noticed that the compressor and turbine assumed performances of KAIST MMR were conservatively selected previously. Thus, this paper tries to address the best estimate values of each turbomachinery in 10MWe class KAIST MMR. The turbomachinery size of the S-CO{sub 2} cycle is smaller than helium Brayton cycle and steam Rankine cycle. The suggested SMR concept adopts passive cooling system by using air. This method can cool reactor without external electricity supply. Small size and more flexible installation in the inland area will be necessary characteristics for the future nuclear application in the water limited region. KAIST MMR meets all these requirements by utilizing S-CO{sub 2} as a working fluid. This paper presents the work for further increasing the system performance by estimating the component efficiency more realistically. The cycle layout adopted for the application is S-CO{sub 2} recuperated Brayton cycle. The best efficiency of compressor and turbine was evaluated to be 84.94% and 90.94%, respectively. By using KAIST in-house code, thermal efficiency and net output were increased to 35.81% and 12.45MWe, respectively, for the same core thermal power. More refined cycle layout and suitable turbomachinery design will be performed in the near future.

  7. Operating conditions of an open and direct solar thermal Brayton cycle with optimised cavity receiver and recuperator

    International Nuclear Information System (INIS)

    Le Roux, W.G.; Bello-Ochende, T.; Meyer, J.P.

    2011-01-01

    The small-scale open and direct solar thermal Brayton cycle with recuperator has several advantages, including low cost, low operation and maintenance costs and it is highly recommended. The main disadvantages of this cycle are the pressure losses in the recuperator and receiver, turbomachine efficiencies and recuperator effectiveness, which limit the net power output of such a system. The irreversibilities of the solar thermal Brayton cycle are mainly due to heat transfer across a finite temperature difference and fluid friction. In this paper, thermodynamic optimisation is applied to concentrate on these disadvantages in order to optimise the receiver and recuperator and to maximise the net power output of the system at various steady-state conditions, limited to various constraints. The effects of wind, receiver inclination, rim angle, atmospheric temperature and pressure, recuperator height, solar irradiance and concentration ratio on the optimum geometries and performance were investigated. The dynamic trajectory optimisation method was applied. Operating points of a standard micro-turbine operating at its highest compressor efficiency and a parabolic dish concentrator diameter of 16 m were considered. The optimum geometries, minimum irreversibility rates and maximum receiver surface temperatures of the optimised systems are shown. For an environment with specific conditions and constraints, there exists an optimum receiver and recuperator geometry so that the system produces maximum net power output. -- Highlights: → Optimum geometries exist such that the system produces maximum net power output. → Optimum operating conditions are shown. → Minimum irreversibility rates and minimum entropy generation rates are shown. → Net power output was described in terms of total entropy generation rate. → Effects such as wind, recuperator height and irradiance were investigated.

  8. Energy and exergy analysis of a closed Brayton cycle-based combined cycle for solar power tower plants

    International Nuclear Information System (INIS)

    Zare, V.; Hasanzadeh, M.

    2016-01-01

    Highlights: • A novel combined cycle is proposed for solar power tower plants. • The effects of solar subsystem and power cycle parameters are examined. • The proposed combined cycle yields exergy efficiencies of higher than 70%. • For the overall power plant exergy efficiencies of higher than 30% is achievable. - Abstract: Concentrating Solar Power (CSP) technology offers an interesting potential for future power generation and research on CSP systems of all types, particularly those with central receiver system (CRS) has been attracting a lot of attention recently. Today, these power plants cannot compete with the conventional power generation systems in terms of Levelized Cost of Electricity (LCOE) and if a competitive LCOE is to be reached, employing an efficient thermodynamic power cycle is deemed essential. In the present work, a novel combined cycle is proposed for power generation from solar power towers. The proposed system consists of a closed Brayton cycle, which uses helium as the working fluid, and two organic Rankine cycles which are employed to recover the waste heat of the Brayton cycle. The system is thermodynamically assessed from both the first and second law viewpoints. A parametric study is conducted to examine the effects of key operating parameters (including solar subsystem and power cycle parameters) on the overall power plant performance. The results indicate that exergy efficiencies of higher than 30% are achieved for the overall power plant. Also, according to the results, the power cycle proposed in this work has a better performance than the other investigated Rankine and supercritical CO_2 systems operating under similar conditions, for these types of solar power plants.

  9. Safety and feasibility of local myocardial hypothermia

    NARCIS (Netherlands)

    Otterspoor, L.C.; van 't Veer, M.; van Nunen, L.X.; Wijnbergen, I.F.; Tonino, W.A.L.; Pijls, N.H.J.

    2016-01-01

    Background In ST-elevation myocardial infarction (STEMI), reduction in time to reperfusion of the occluded coronary artery reduces infarct size. In animal models, an additional reduction of infarct size was observed when hypothermia was induced before reperfusion, despite a longer ischemic time.

  10. Feasibility Analysis and Safety Evaluation of Coal Mining above High Confined Water%高承压水上采煤可行性分析及安全开采评价

    Institute of Scientific and Technical Information of China (English)

    申建军; 刘伟韬; 王现伟; 刘云娟

    2013-01-01

    针对深部矿井承压水上采煤导致的底板突水问题,在深部开拓时,必须进行必要的可行性分析和安全开采评价.通过对某矿区深部扩大区水文地质条件分析,认为该区域煤矿可开采.利用底板岩体渗流模型及修正的水力参数,基于FLAC3D各向异性渗透模型进行应力场-渗流场耦合模拟,得出底板破坏深度.结果表明:正常区段工作面底板破坏深度为25 m,受构造破坏区段底板破坏深度为50 m.根据突水系数法对安全开采深度及工作面斜长进行了评价,提出了可行的水害防治措施.保持0.06 MPa/m的突水系数,采取疏水降压措施,把水头疏降到-950 m标高时,15煤层工作面的开采是安全的.%In order to overcome floor water inrush under mining above confined water,especially for deep mine,it's necessary to analyze the feasibility and make the safety evaluation before development and mining.According to the hydrogeological conditions analysis at deep mining area of a certain mine,it is considered that this area is available to mining.With the use of the floor seepage model and the modified hydraulic parameters,and based on FLAC3D anisotropic permeability model,the coupled simulation of stress field-seepage field is simulated to obtain the depth of floor failure.The results show that the floor damage deepness at normal region and at structural damage region are about 25 m and 50 m respectively.According to the water bursting coefficient,the safety depth of mining and the length of working face are evaluated.At the same time,prevention and treatment measures of water disaster are also presented.Keeping the water bursting coefficient of 0.06 MPa/m,taking hydrophobic decompression measures,lowering the water head to-950 m level,it is safe to recover the 15# coal seam.

  11. Locomotor training using an overground robotic exoskeleton in long-term manual wheelchair users with a chronic spinal cord injury living in the community: Lessons learned from a feasibility study in terms of recruitment, attendance, learnability, performance and safety.

    Science.gov (United States)

    Gagnon, Dany H; Escalona, Manuel J; Vermette, Martin; Carvalho, Lívia P; Karelis, Antony D; Duclos, Cyril; Aubertin-Leheudre, Mylène

    2018-03-01

    For individuals who sustain a complete motor spinal cord injury (SCI) and rely on a wheelchair as their primary mode of locomotion, overground robotic exoskeletons represent a promising solution to stand and walk again. Although overground robotic exoskeletons have gained tremendous attention over the past decade and are now being transferred from laboratories to clinical settings, their effects remain unclear given the paucity of scientific evidence and the absence of large-scale clinical trials. This study aims to examine the feasibility of a locomotor training program with an overground robotic exoskeleton in terms of recruitment, attendance, and drop-out rates as well as walking performance, learnability, and safety. Individuals with a SCI were invited to participate in a 6 to 8-week locomotor training program with a robotic exoskeleton encompassing 18 sessions. Selected participants underwent a comprehensive screening process and completed two familiarization sessions with the robotic exoskeleton. The outcome measures were the rate of recruitment of potential participants, the rate of attendance at training sessions, the rate of drop-outs, the ability to walk with the exoskeleton, and its progression over the program as well as the adverse events. Out of 49 individuals who expressed their interest in participating in the study, only 14 initiated the program (recruitment rate = 28.6%). Of these, 13 individuals completed the program (drop-out rate = 7.1%) and attended 17.6 ± 1.1 sessions (attendance rate = 97.9%). Their greatest standing time, walking time, and number of steps taken during a session were 64.5 ± 10.2 min, 47.2 ± 11.3 min, and 1843 ± 577 steps, respectively. During the training program, these last three parameters increased by 45.3%, 102.1%, and 248.7%, respectively. At the end of the program, when walking with the exoskeleton, most participants required one therapist (85.7%), needed stand-by or contact

  12. Safety and feasibility of performing staged non-culprit vessel percutaneous coronary intervention within the index hospitalization in patients with ST-segment elevation myocardial infarction and multivessel disease

    International Nuclear Information System (INIS)

    Loh, Joshua P.; Kitabata, Hironori; Torguson, Rebecca; Satler, Lowell F.; Kent, Kenneth M.; Suddath, William O.; Pichard, Augusto D.; Lindsay, Joseph; Waksman, Ron

    2013-01-01

    Objectives: To determine whether staged percutaneous coronary intervention (PCI) within the same hospitalization as primary PCI is safe. Background: In ST-segment elevation myocardial infarction (STEMI) patients with multivessel disease undergoing primary PCI, staged non-culprit vessel PCI at a separate session is recommended. Methods: We conducted a retrospective analysis of 282 consecutive STEMI patients with multivessel disease who underwent primary PCI followed by staged PCI of the non-culprit vessel. Patients were categorized into staged PCI in the same hospitalization (n = 184) and staged PCI at a separate hospitalization within 8 weeks of primary PCI (n = 98). Results: Baseline characteristics, presentation of STEMI, and procedural characteristics were similar in both groups. Contrast amount was higher in the separate hospitalization group for both index (175 vs. 153 ml, p = 0.011) and staged (144 vs. 120 ml, p = 0.004) procedures. More staged left main PCI was performed in the separate hospitalization group (3.9 vs. 0.3%, p = 0.008). Angiographic success of staged PCI was similar in both groups, with similar rates of vascular complications and major bleeding. Following staged PCI, in-hospital major adverse cardiac events (3.3 vs. 1.0%, p = 0.43) and mortality (2.7 vs. 0%, p = 0.17) were similar in both groups. Conclusions: Our study supports the safety and feasibility of staged PCI within the same hospitalization as primary PCI, achieving similar procedural success and in-hospital outcomes as staged PCI at a separate hospitalization. Higher contrast amount used during primary PCI and presence of left main lesion in non-culprit vessels may influence the decision to stage the PCI at a separate hospitalization

  13. Intraoperative and postoperative feasibility and safety of total tubeless, tubeless, small-bore tube, and standard percutaneous nephrolithotomy: a systematic review and network meta-analysis of 16 randomized controlled trials.

    Science.gov (United States)

    Lee, Joo Yong; Jeh, Seong Uk; Kim, Man Deuk; Kang, Dong Hyuk; Kwon, Jong Kyou; Ham, Won Sik; Choi, Young Deuk; Cho, Kang Su

    2017-06-27

    Percutaneous nephrolithotomy (PCNL) is performed to treat relatively large renal stones. Recent publications indicate that tubeless and total tubeless (stentless) PCNL is safe in selected patients. We performed a systematic review and network meta-analysis to evaluate the feasibility and safety of different PCNL procedures, including total tubeless, tubeless with stent, small-bore tube, and large-bore tube PCNLs. PubMed, Cochrane Central Register of Controlled Trials, and EMBASE™ databases were searched to identify randomized controlled trials published before December 30, 2013. One researcher examined all titles and abstracts found by the searches. Two investigators independently evaluated the full-text articles to determine whether those met the inclusion criteria. Qualities of included studies were rated with Cochrane's risk-of-bias assessment tool. Sixteen studies were included in the final syntheses including pairwise and network meta-analyses. Operation time, pain scores, and transfusion rates were not significantly different between PCNL procedures. Network meta-analyses demonstrated that for hemoglobin changes, total tubeless PCNL may be superior to standard PCNL (mean difference [MD] 0.65, 95% CI 0.14-1.13) and tubeless PCNLs with stent (MD -1.14, 95% CI -1.65--0.62), and small-bore PCNL may be superior to tubeless PCNL with stent (MD 1.30, 95% CI 0.27-2.26). Network meta-analyses also showed that for length of hospital stay, total tubeless (MD 1.33, 95% CI 0.23-2.43) and tubeless PCNLs with stent (MD 0.99, 95% CI 0.19-1.79) may be superior to standard PCNL. In rank probability tests, small-bore tube and total tubeless PCNLs were superior for operation time, pain scores, and hemoglobin changes. For hemoglobin changes, total tubeless and small-bore PCNLs may be superior to other methods. For hospital stay, total tubeless and tubeless PCNLs with stent may be superior to other procedures.

  14. Evaluation of technical feasibility of closed-cycle non-equilibrium MHD power generation with direct coal firing. Final report, Task I

    Energy Technology Data Exchange (ETDEWEB)

    1981-11-01

    Program accomplishments in a continuing effort to demonstrate the feasibility of direct coal-fired, closed-cycle MHD power generation are reported. This volume contains the following appendices: (A) user's manual for 2-dimensional MHD generator code (2DEM); (B) performance estimates for a nominal 30 MW argon segmented heater; (C) the feedwater cooled Brayton cycle; (D) application of CCMHD in an industrial cogeneration environment; (E) preliminary design for shell and tube primary heat exchanger; and (F) plant efficiency as a function of output power for open and closed cycle MHD power plants. (WHK)

  15. Universal Expression of Efficiency at Maximum Power: A Quantum-Mechanical Brayton Engine Working with a Single Particle Confined in a Power-Law Trap

    International Nuclear Information System (INIS)

    Ye Zhuo-Lin; Li Wei-Sheng; Lai Yi-Ming; He Ji-Zhou; Wang Jian-Hui

    2015-01-01

    We propose a quantum-mechanical Brayton engine model that works between two superposed states, employing a single particle confined in an arbitrary power-law trap as the working substance. Applying the superposition principle, we obtain the explicit expressions of the power and efficiency, and find that the efficiency at maximum power is bounded from above by the function: η_+ = θ/(θ + 1), with θ being a potential-dependent exponent. (paper)

  16. Detailed analysis of the effect of the turbine and compressor isentropic efficiency on the thermal and exergy efficiency of a Brayton cycle

    Directory of Open Access Journals (Sweden)

    Živić Marija

    2014-01-01

    Full Text Available Energy and exergy analysis of a Brayton cycle with an ideal gas is given. The irreversibility of the adiabatic processes in turbine and compressor is taken into account through their isentropic efficiencies. The net work per cycle, the thermal efficiency and the two exergy efficiencies are expressed as functions of the four dimensionless variables: the isentropic efficiencies of turbine and compressor, the pressure ratio, and the temperature ratio. It is shown that the maximal values of the net work per cycle, the thermal and the exergy efficiency are achieved when the isentropic efficiencies and temperature ratio are as high as possible, while the different values of pressure ratio that maximize the net work per cycle, the thermal and the exergy efficiencies exist. These pressure ratios increase with the increase of the temperature ratio and the isentropic efficiency of compressor and turbine. The increase of the turbine isentropic efficiency has a greater impact on the increase of the net work per cycle and the thermal efficiency of a Brayton cycle than the same increase of compressor isentropic efficiency. Finally, two goal functions are proposed for thermodynamic optimization of a Brayton cycle for given values of the temperature ratio and the compressor and turbine isentropic efficiencies. The first maximizes the sum of the net work per cycle and thermal efficiency while the second the net work per cycle and exergy efficiency. In both cases the optimal pressure ratio is closer to the pressure ratio that maximizes the net work per cycle.

  17. Performance of supercritical Brayton cycle using CO2-based binary mixture at varying critical points for SFR applications

    International Nuclear Information System (INIS)

    Jeong, Woo Seok; Jeong, Yong Hoon

    2013-01-01

    Highlights: • Supercritical CO 2 -based gas mixture Brayton cycles were investigated for a SFR. • The critical point of CO 2 is the lowest cycle operating limit of the S-CO 2 cycles. • Mixing additives with CO 2 changes the CO 2 critical point. • CO 2 –Xe and CO 2 –Kr cycles achieve higher cycle efficiencies than the S-CO 2 cycles. • CO 2 –H 2 S and CO 2 –cyclohexane cycles perform better at higher heat sink temperatures. -- Abstract: The supercritical carbon dioxide Brayton cycle (S-CO 2 cycle) has attracted much attention as an alternative to the Rankine cycle for sodium-cooled fast reactors (SFRs). The higher cycle efficiency of the S-CO 2 cycle results from the considerably decreased compressor work because the compressor behaves as a pump in the proximity of the CO 2 vapor–liquid critical point. In order to fully utilize this feature, the main compressor inlet condition should be controlled to be close to the critical point of CO 2 . This indicates that the critical point of CO 2 is a constraint on the minimum cycle condition for S-CO 2 cycles. Modifying the CO 2 critical point by mixing additive gases could be considered as a method of enhancing the performance and broadening the applicability of the S-CO 2 cycle. Due to the drastic fluctuations of the thermo-physical properties of fluids near the critical point, an in-house cycle analysis code using the NIST REFPROP database was implemented. Several gases were selected as potential additives considering their thermal stability and chemical interaction with sodium in the temperature range of interest and the availability of the mixture property database: xenon, krypton, hydrogen sulfide, and cyclohexane. The performances of the optimized CO 2 -containing binary mixture cycles with simple recuperated and recompression layouts were compared with the reference S-CO 2 , CO 2 –Ar, CO 2 –N 2 , and CO 2 –O 2 cycles. For the decreased critical temperatures, the CO 2 –Xe and CO 2

  18. Feasibility of Ericsson type isothermal expansion/compression gas turbine cycle for nuclear energy use

    International Nuclear Information System (INIS)

    Shimizu, Akihiko

    2007-01-01

    A gas turbine with potential demand for the next generation nuclear energy use such as HTGR power plants, a gas cooled FBR, a gas cooled nuclear fusion reactor uses helium as working gas and with a closed cycle. Materials constituting a cycle must be set lower than allowable temperature in terms of mechanical strength and radioactivity containment performance and so expansion inlet temperature is remarkably limited. For thermal efficiency improvement, isothermal expansion/isothermal compression Ericsson type gas turbine cycle should be developed using wet surface of an expansion/compressor casing and a duct between stators without depending on an outside heat exchanger performing multistage re-heat/multistage intermediate cooling. Feasibility of an Ericsson cycle in comparison with a Brayton cycle and multi-stage compression/expansion cycle was studied and technologies to be developed were clarified. (author)

  19. Conceptual Design Study of a Closed Brayton Cycle Turbogenerator for Space Power Thermal-To-Electric Conversion System

    Science.gov (United States)

    Hansen, Jeff L.

    2000-01-01

    A conceptual design study was completed for a 360 kW Helium-Xenon closed Brayton cycle turbogenerator. The selected configuration is comprised of a single-shaft gas turbine engine coupled directly to a high-speed generator. The engine turbomachinery includes a 2.5:1 pressure ratio compression system with an inlet corrected flow of 0.44 kg/sec. The single centrifugal stage impeller discharges into a scroll via a vaned diffuser. The scroll routes the air into the cold side sector of the recuperator. The hot gas exits a nuclear reactor radiator at 1300 K and enters the turbine via a single-vaned scroll. The hot gases are expanded through the turbine and then diffused before entering the hot side sector of the recuperator. The single shaft design is supported by air bearings. The high efficiency shaft mounted permanent magnet generator produces an output of 370 kW at a speed of 60,000 rpm. The total weight of the turbogenerator is estimated to be only 123 kg (less than 5% of the total power plant) and has a volume of approximately 0.11 cubic meters. This turbogenerator is a key element in achieving the 40 to 45% overall power plant thermal efficiency.

  20. A Conceptual Study of Using an Isothermal Compressor on a Supercritical CO_2 Brayton Cycle for SMART Application

    International Nuclear Information System (INIS)

    Heo, Jin Young; Lee, Jeong Ik; Ahn, Yoonhan

    2016-01-01

    To maximize the benefits of modularization, the supercritical CO_2 (S-CO_2) power cycle can replace the conventional steam Rankine cycle to increase the cycle efficiency and reduce its system size. Previous works have been conducted to evaluate potential advantages of applying the S-CO_2 cycle to SMRs, specifically to SMART (System-integrated Modular Advanced Reactor) which is an integral SMR developed by KAERI (Korea Atomic Energy Institute). One of the optimized S-CO_2 cycle layouts is the recompressing Brayton cycle. This paper attempts to improve the cycle layout by replacing the conventional compressor with an isothermal compressor, of which its potential in the S-CO_2 power cycle is conceptually being evaluated. The SMR applications, for which SMART reactor has been represented, can take advantage of the currently developing S-CO_2 cycle greatly by the reduction of size. By introducing the isothermal compressor, the cycle layout considered in has been further improved by increasing the cycle net efficiency by around 0.5%

  1. Integrated solar thermal Brayton cycles with either one or two regenerative heat exchangers for maximum power output

    International Nuclear Information System (INIS)

    Jansen, E.; Bello-Ochende, T.; Meyer, J.P.

    2015-01-01

    The main objective of this paper is to optimise the open-air solar-thermal Brayton cycle by considering the implementation of the second law of thermodynamics and how it relates to the design of the heat exchanging components within it. These components included one or more regenerators (in the form of cross-flow heat exchangers) and the receiver of a parabolic dish concentrator where the system heat was absorbed. The generation of entropy was considered as it was associated with the destruction of exergy or available work. The dimensions of some components were used to optimise the cycles under investigation. EGM (Entropy Generation Minimisation) was employed to optimise the system parameters by considering their influence on the total generation of entropy (destruction of exergy). Various assumptions and constraints were considered and discussed. The total entropy generation rate and irreversibilities were determined by considering the individual components and ducts of the system, as well as their respective inlet and outlet conditions. The major system parameters were evaluated as functions of the mass flow rate to allow for a proper discussion of the system performance. The performances of both systems were investigated, and characteristics were listed for both. Finally, a comparison is made to shed light on the differences in performance. - Highlights: • Implementation of the second law of thermodynamics. • Design of heat exchanging and collecting equipment. • Utilisation of Entropy Generation Minimization. • Presentation of a multi-objective optimization. • Raise efficiency with more regeneration

  2. Multi-objective thermodynamic optimization of an irreversible regenerative Brayton cycle using evolutionary algorithm and decision making

    Directory of Open Access Journals (Sweden)

    Rajesh Kumar

    2016-06-01

    Full Text Available Brayton heat engine model is developed in MATLAB simulink environment and thermodynamic optimization based on finite time thermodynamic analysis along with multiple criteria is implemented. The proposed work investigates optimal values of various decision variables that simultaneously optimize power output, thermal efficiency and ecological function using evolutionary algorithm based on NSGA-II. Pareto optimal frontier between triple and dual objectives is obtained and best optimal value is selected using Fuzzy, TOPSIS, LINMAP and Shannon’s entropy decision making methods. Triple objective evolutionary approach applied to the proposed model gives power output, thermal efficiency, ecological function as (53.89 kW, 0.1611, −142 kW which are 29.78%, 25.86% and 21.13% lower in comparison with reversible system. Furthermore, the present study reflects the effect of various heat capacitance rates and component efficiencies on triple objectives in graphical custom. Finally, with the aim of error investigation, average and maximum errors of obtained results are computed.

  3. A Conceptual Study of Using an Isothermal Compressor on a Supercritical CO{sub 2} Brayton Cycle for SMART Application

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Jin Young; Lee, Jeong Ik [KAIST, Daejeon (Korea, Republic of); Ahn, Yoonhan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    To maximize the benefits of modularization, the supercritical CO{sub 2} (S-CO{sub 2}) power cycle can replace the conventional steam Rankine cycle to increase the cycle efficiency and reduce its system size. Previous works have been conducted to evaluate potential advantages of applying the S-CO{sub 2} cycle to SMRs, specifically to SMART (System-integrated Modular Advanced Reactor) which is an integral SMR developed by KAERI (Korea Atomic Energy Institute). One of the optimized S-CO{sub 2} cycle layouts is the recompressing Brayton cycle. This paper attempts to improve the cycle layout by replacing the conventional compressor with an isothermal compressor, of which its potential in the S-CO{sub 2} power cycle is conceptually being evaluated. The SMR applications, for which SMART reactor has been represented, can take advantage of the currently developing S-CO{sub 2} cycle greatly by the reduction of size. By introducing the isothermal compressor, the cycle layout considered in has been further improved by increasing the cycle net efficiency by around 0.5%.

  4. Preliminary hazard analysis for the Brayton Isotope Ground Demonstration System (including vacuum test chamber)

    International Nuclear Information System (INIS)

    Miller, L.G.

    1975-01-01

    The Preliminary Hazard Analysis (PHA) of the BIPS-GDS is a tabular summary of hazards and undesired events which may lead to system damage or failure and/or hazard to personnel. The PHA reviews the GDS as it is envisioned to operate in the Vacuum Test Chamber (VTC) of the GDS Test Facility. The VTC and other equipment which will comprise the test facility are presently in an early stage of preliminary design and will undoubtedly undergo numerous changes before the design is frozen. The PHA and the FMECA to follow are intended to aid the design effort by identifying areas of concern which are critical to the safety and reliability of the BIPS-GDS and test facility

  5. Preliminary Failure Modes, Effects and Criticality Analysis (FMECA) of the Brayton Isotope Power System (BIPS) Ground Demonstration System. Report 76-311965

    International Nuclear Information System (INIS)

    Miller, L.G.

    1976-01-01

    A Failure Modes, Effects and Criticality Analysis (FMECA) has been made of the Brayton Isotope Power System Ground Demonstration System (BIPS-GDS). Details of the analysis are discussed. The BIPS Flight System was recently analyzed in an AIRPHX report. Since the results of the Flight System FMECA are directly applicable to the BIPS to be tested in the GDS mode, the contents of the earlier FMECA have not been repeated in this current analysis. The BIPS-FS FMECA has been reviewed and determined to be essentially current

  6. Development and validation of models for simulation of supercritical carbon dioxide Brayton cycles and application to self-propelling heat removal systems in boiling water reactors

    Energy Technology Data Exchange (ETDEWEB)

    Venker, Jeanne

    2015-03-31

    The objective of the current work was to develop a model that is able to describe the transient behavior of supercritical carbon dioxide (sCO{sub 2}) Brayton cycles, to be applied to self-propelling residual heat removal systems in boiling water reactors. The developed model has been implemented into the thermohydraulic system code ATHLET. By means of this improved ATHLET version, novel residual heat removal systems, which are based on closed sCO{sub 2} Brayton cycles, can be assessed as a retrofit measure for present light water reactors. Transient simulations are hereby of great importance. The heat removal system has to be modeled explicitly to account for the interaction between the system and the behavior of the plant during different accident conditions. As a first step, transport and thermodynamic fluid properties of supercritical carbon dioxide have been implemented in ATHLET to allow for the simulation of the new working fluid. Additionally, a heat transfer correlation has been selected to represent the specific heat transfer of supercritical carbon dioxide. For the calculation of pressure losses due to wall friction, an approach for turbulent single phase flow has been adopted that is already implemented in ATHLET. In a second step, a component model for radial compressors has been implemented in the system code. Furthermore, the available model for axial turbines has been adapted to simulate the transient behavior of radial turbines. All extensions have been validated against experimental data. In order to simulate the interaction between the self-propelling heat removal system and a generic boiling water reactor, the components of the sCO{sub 2} Brayton cycle have been dimensioned with first principles. An available input deck of a generic BWR has then been extended by the residual heat removal system. The modeled application has shown that the extended version of ATHLET is suitable to simulate sCO{sub 2} Brayton cycles and to evaluate the introduced

  7. Development and validation of models for simulation of supercritical carbon dioxide Brayton cycles and application to self-propelling heat removal systems in boiling water reactors

    International Nuclear Information System (INIS)

    Venker, Jeanne

    2015-01-01

    The objective of the current work was to develop a model that is able to describe the transient behavior of supercritical carbon dioxide (sCO 2 ) Brayton cycles, to be applied to self-propelling residual heat removal systems in boiling water reactors. The developed model has been implemented into the thermohydraulic system code ATHLET. By means of this improved ATHLET version, novel residual heat removal systems, which are based on closed sCO 2 Brayton cycles, can be assessed as a retrofit measure for present light water reactors. Transient simulations are hereby of great importance. The heat removal system has to be modeled explicitly to account for the interaction between the system and the behavior of the plant during different accident conditions. As a first step, transport and thermodynamic fluid properties of supercritical carbon dioxide have been implemented in ATHLET to allow for the simulation of the new working fluid. Additionally, a heat transfer correlation has been selected to represent the specific heat transfer of supercritical carbon dioxide. For the calculation of pressure losses due to wall friction, an approach for turbulent single phase flow has been adopted that is already implemented in ATHLET. In a second step, a component model for radial compressors has been implemented in the system code. Furthermore, the available model for axial turbines has been adapted to simulate the transient behavior of radial turbines. All extensions have been validated against experimental data. In order to simulate the interaction between the self-propelling heat removal system and a generic boiling water reactor, the components of the sCO 2 Brayton cycle have been dimensioned with first principles. An available input deck of a generic BWR has then been extended by the residual heat removal system. The modeled application has shown that the extended version of ATHLET is suitable to simulate sCO 2 Brayton cycles and to evaluate the introduced heat removal system

  8. Use of High-Power Brayton Nuclear Electric Propulsion (NEP) for a 2033 Mars Round-Trip Mission

    International Nuclear Information System (INIS)

    McGuire, Melissa L.; Martini, Michael C.; Packard, Thomas W.; Weglian, John E.; Gilland, James H.

    2006-01-01

    The Revolutionary Aerospace Systems Concepts (RASC) team, led by the NASA Langley Research Center, is tasked with exploring revolutionary new approaches to enabling NASA to achieve its strategic goals and objectives in future missions. This paper provides the details from the 2004-2005 RASC study of a point-design that uses a high-power nuclear electric propulsion (NEP) based space transportation architecture to support a manned mission to Mars. The study assumes a high-temperature liquid-metal cooled fission reactor with a Brayton power conversion system to generate the electrical power required by magnetoplasmadynamic (MPD) thrusters. The architecture includes a cargo vehicle with an NEP system providing 5 MW of electrical power and a crewed vehicle with an NEP system with two reactors providing a combined total of 10 MW of electrical power. Both vehicles use a low-thrust, high-efficiency (5000 sec specific impulse) MPD system to conduct a spiral-out of the Earth gravity well, a low-thrust heliocentric trajectory, and a spiral-in at Mars with arrival late in 2033. The cargo vehicle carries two moon landers to Mars and arrives shortly before the crewed vehicle. The crewed vehicle and cargo vehicle rendezvous in Mars orbit and, over the course of the 60-day stay, the crew conducts nine-day excursions to Phobos and Deimos with the landers. The crewed vehicle then spirals out of Martian orbit and returns via a low-thrust trajectory to conduct an Earth flyby. The crew separates from the vehicle prior to Earth flyby and aerobrakes for a direct-entry landing

  9. Optimal temperature of operation of the cold side of a closed Brayton Cycle for space nuclear propulsion

    Energy Technology Data Exchange (ETDEWEB)

    Romano, Luís F.R.; Ribeiro, Guilherme B., E-mail: luisromano_91@hotmail.com, E-mail: gbribeiro@ieav.cta.br [Instituto Tecnológico de Aeronáutica (ITA), São José dos Campos, SP (Brazil). Pós-Graduação Ciências e Tecnologias Espaciais

    2017-07-01

    Generating energy in space is a tough challenge, especially because it has to be used efficiently. The optimization of the system operation has to be though up since the design phase and all the minutiae between conception, production and operation should be carefully evaluated in order to deliver a functioning device that will meet all the mission's goals. This work seeks on further describing the operation of a Closed Brayton Cycle coupled toa nuclear microreactor used to generate energy to power spacecraft's systems, focusing specially on the cold side to evaluate the temperature of operation of the cold heat pipes in order to aid the selection of proper models to numerically describe the heat pipes and radiator s thermal operation. The cycle is designed to operate with a noble gas mixture of Helium-Xenon with a molecular weight of 40g/mole, selected for its transport properties and low turbomachinery charge and it is to exchange hear directly with the cold heat pipe' evaporator through convection at the cold heat exchanger. Properties such as size and mass are relevant to be analyzed due space applications requiring a careful development of the equipment in order to fit inside the launcher as well as lowering launch costs. Merit figures comparing both second law energetic efficiency and net energy availability with the device's radiator size are used in order to represent an energetic production density for the apparatus, which is ought to be launched from earth's surface. (author)

  10. Optimal temperature of operation of the cold side of a closed Brayton Cycle for space nuclear propulsion

    International Nuclear Information System (INIS)

    Romano, Luís F.R.; Ribeiro, Guilherme B.

    2017-01-01

    Generating energy in space is a tough challenge, especially because it has to be used efficiently. The optimization of the system operation has to be though up since the design phase and all the minutiae between conception, production and operation should be carefully evaluated in order to deliver a functioning device that will meet all the mission's goals. This work seeks on further describing the operation of a Closed Brayton Cycle coupled toa nuclear microreactor used to generate energy to power spacecraft's systems, focusing specially on the cold side to evaluate the temperature of operation of the cold heat pipes in order to aid the selection of proper models to numerically describe the heat pipes and radiator s thermal operation. The cycle is designed to operate with a noble gas mixture of Helium-Xenon with a molecular weight of 40g/mole, selected for its transport properties and low turbomachinery charge and it is to exchange hear directly with the cold heat pipe' evaporator through convection at the cold heat exchanger. Properties such as size and mass are relevant to be analyzed due space applications requiring a careful development of the equipment in order to fit inside the launcher as well as lowering launch costs. Merit figures comparing both second law energetic efficiency and net energy availability with the device's radiator size are used in order to represent an energetic production density for the apparatus, which is ought to be launched from earth's surface. (author)

  11. Playground Safety

    Science.gov (United States)

    ... Prevention Fall Prevention Playground Safety Poisoning Prevention Road Traffic Safety Sports Safety Get Email Updates To receive ... at the Consumer Product Safety Commission’s Playground Safety website . References U.S. Consumer Product Safety Commission. Injuries and ...

  12. Development of a Performance Analysis Code for the Off-design conditions of a S-CO2 Brayton Cycle Energy Conversion System

    International Nuclear Information System (INIS)

    Yoo, Yong-Hwan; Cha, Jae-Eun; Lee, Tae-Ho; Eoh, Jae-Hyuk; Kim, Seong-O

    2008-01-01

    For the development of a supercritical carbon dioxide (S-CO2) Brayton cycle energy conversion system coupled to KALIMER-600, a thermal balance has been established on 100% power operating conditions including all the reactor system models such as a primary heat transport system (PHTS), an intermediate heat transport system (IHTS), and an energy conversion system. The S-CO2 Brayton cycle energy conversion system consists of a sodium-CO2 heat exchanger (Hx), turbine, high temperature recuperate (HTR), low temperature recuperate (LTR), precooler, compressor no.1, and compressor no.2. Two compressors were employed to avoid a sharp change of the physical properties near their critical point with a corresponding pressure. The component locations and their operating conditions are illustrated. Energy balance of the power conversion system in KALIMER-600 was designed with the full power condition of each component. Therefore, to predict the off-design conditions and to evaluate each component, an off-design performance analysis code should be accomplished. An off-design performance analysis could be classified into overall system control logic and local system control logic. The former means that mass flow rate and power are controlled by valves, and the latter implies that a bypass or inventory control is an admitted system balance. The ultimate goal of this study is development of the overall system control logic

  13. Steady-state temperature distribution within a Brayton rotating unit operating in a power conversion system using helium-xenon gas

    Science.gov (United States)

    Johnsen, R. L.; Namkoong, D.; Edkin, R. A.

    1971-01-01

    The Brayton rotating unit (BRU), consisting of a turbine, an alternator, and a compressor, was tested as part of a Brayton cycle power conversion system over a side range of steady state operating conditions. The working fluid in the system was a mixture of helium-xenon gases. Turbine inlet temperature was varied from 1200 to 1600 F, compressor inlet temperature from 60 to 120 F, compressor discharge pressure from 20 to 45 psia, rotative speed from 32 400 to 39 600 rpm, and alternator liquid-coolant flow rate from 0.01 to 0.27 pound per second. Test results indicated that the BRU internal temperatures were highly sensitive to alternator coolant flow below the design value of 0.12 pound per second but much less so at higher values. The armature winding temperature was not influenced significantly by turbine inlet temperature, but was sensitive, up to 20 F per kVA alternator output, to varying alternator output. When only the rotational speed was changed (+ or - 10% of rated value), the BRU internal temperatures varied directly with the speed.

  14. Transient Model of a 10 MW Supercritical CO{sub 2} Brayton Cycle for Light Water Reactors by using MARS Code

    Energy Technology Data Exchange (ETDEWEB)

    Park, Joo-Hyun; Park, Hyun Sun; Kim, Moo Hwan [POSTECH, Pohang (Korea, Republic of); Bae, Sung Won; Cha, Jae-Eun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    In this study, recuperation cycle was chosen as a reference loop design and the MARS code was chosen as the transient cycle analysis code. Cycle design condition is focus on operation point of the light-water reactor. Development of a transient model was performed for 10MW-electron SCO{sub 2} coupled with light water reactors. In order to perform transient analysis, cycle transient model was developed and steady-state run was performed and presented in the paper. In this study, the transient model of SCO{sub 2} recuperation Brayton cycle was developed and implemented in MARS to study the steady-state simulation. We performed nodalization of the transient model using MARS code and obtained steady-state results. This study is shown that the supercritical CO{sub 2} Brayton cycle can be used as a power conversion system for light water reactors. Future work will include transient analysis such as partial road operation, power swing, start-up, and shutdown. Cycle control strategy will be considered for various control method.

  15. An improved model to evaluate thermodynamic solar plants with cylindrical parabolic collectors and air turbine engines in open Joule–Brayton cycle

    International Nuclear Information System (INIS)

    Ferraro, Vittorio; Imineo, Francesco; Marinelli, Valerio

    2013-01-01

    An improved model to analyze the performance of solar plants operating with cylindrical parabolic collectors and atmospheric air as heat transfer fluid in an open Joule–Brayton cycle is presented. In the new model, the effect of the incident angle modifier is included, to take into account the variation of the optical efficiency with the incidence angle of the irradiance, and the effect of the reheating of the fluid also has been studied. The analysis was made for two operating modes of the plants: with variable air flow rate and constant inlet temperature to the turbine and with constant flow rate and variable inlet temperature to the turbine, with and without reheating of the fluid in the solar field. When reheating is used, the efficiency of the plant is increased. The obtained results show a good performance of this type of solar plant, in spite of its simplicity; it is able to compete well with other more complex plants operating with different heat transfer fluids. - Highlights: ► An improved model to calculate an innovative CPS solar plant is presented. ► The plant works with air in an open Joule–Brayton cycle. ► The reheating of the air increases the thermodynamic efficiency. ► The plant is very simple and competes well with other more complex solar plants

  16. Advanced heat pump for the recovery of volatile organic compounds. Phase 1, Conceptual design of an advanced Brayton cycle heat pump for the recovery of volatile organic compounds: Final report

    Energy Technology Data Exchange (ETDEWEB)

    1992-03-01

    Emissions of Volatile Organic Compounds (VOC) from stationary industrial and commercial sources represent a substantial portion of the total US VOC emissions. The ``Toxic-Release Inventory`` of The US Environmental Protection Agency estimates this to be at about 3 billion pounds per year (1987 estimates). The majority of these VOC emissions are from coating processes, cleaning processes, polymer production, fuel production and distribution, foam blowing,refrigerant production, and wood products production. The US Department of Energy`s (DOE) interest in the recovery of VOC stems from the energy embodied in the recovered solvents and the energy required to dispose of them in an environmentally acceptable manner. This Phase I report documents 3M`s work in close working relationship with its subcontractor Nuclear Consulting Services (Nucon) for the preliminary conceptual design of an advanced Brayton cycle heat pump for the recovery of VOC. Nucon designed Brayton cycle heat pump for the recovery of methyl ethyl ketone and toluene from coating operations at 3M Weatherford, OK, was used as a base line for the work under cooperative agreement between 3M and ODE. See appendix A and reference (4) by Kovach of Nucon. This cooperative agreement report evaluates and compares an advanced Brayton cycle heat pump for solvent recovery with other competing technologies for solvent recovery and reuse. This advanced Brayton cycle heat pump is simple (very few components), highly reliable (off the shelf components), energy efficient and economically priced.

  17. Feasible Histories, Maximum Entropy

    International Nuclear Information System (INIS)

    Pitowsky, I.

    1999-01-01

    We consider the broadest possible consistency condition for a family of histories, which extends all previous proposals. A family that satisfies this condition is called feasible. On each feasible family of histories we choose a probability measure by maximizing entropy, while keeping the probabilities of commuting histories to their quantum mechanical values. This procedure is justified by the assumption that decoherence increases entropy. Finally, a criterion for identifying the nearly classical families is proposed

  18. 14-plex Feasibility Report

    Energy Technology Data Exchange (ETDEWEB)

    Kotongan, Victoria Hazel [Native Village of Unalakleet

    2013-06-21

    The Native Village of Unalakleet project was a feasibility study for a retrofit of a “tribally owned” three story, 14 apartment complex located in Unalakleet, Alaska. The program objective and overall goal was to create a plan for retrofitting to include current appraised value and comparable costs of new construction to determine genuine feasibility as low-income multi-family housing for tribal members.

  19. French PWR safety philosophy

    International Nuclear Information System (INIS)

    Conte, M.

    1986-05-01

    Increasing knowledge and lessons learned from starting and operating experience of French nuclear power plants, completed by the experience learned from the operation of foreign reactors, has contributed to the improvement of French PWR design and safety philosophy. Based on a deterministic approach, the French safety analysis was progressively completed by a probabilistic approach, each of them having possibilities and limits. As a consequence of the global risk objective set in 1977 for nuclear reactors, safety analysis was extended to the evaluation of events more complex than the conventional ones, and later to the evaluation of the feasibility of the offsite emergency plans in case of severe accidents

  20. Deep Borehole Disposal Safety Analysis.

    Energy Technology Data Exchange (ETDEWEB)

    Freeze, Geoffrey A. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Stein, Emily [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Price, Laura L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); MacKinnon, Robert J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Tillman, Jack Bruce [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2016-10-01

    This report presents a preliminary safety analysis for the deep borehole disposal (DBD) concept, using a safety case framework. A safety case is an integrated collection of qualitative and quantitative arguments, evidence, and analyses that substantiate the safety, and the level of confidence in the safety, of a geologic repository. This safety case framework for DBD follows the outline of the elements of a safety case, and identifies the types of information that will be required to satisfy these elements. At this very preliminary phase of development, the DBD safety case focuses on the generic feasibility of the DBD concept. It is based on potential system designs, waste forms, engineering, and geologic conditions; however, no specific site or regulatory framework exists. It will progress to a site-specific safety case as the DBD concept advances into a site-specific phase, progressing through consent-based site selection and site investigation and characterization.

  1. Thermodynamic analysis and preliminary design of closed Brayton cycle using nitrogen as working fluid and coupled to small modular Sodium-cooled fast reactor (SM-SFR)

    International Nuclear Information System (INIS)

    Olumayegun, Olumide; Wang, Meihong; Kelsall, Greg

    2017-01-01

    Highlights: • Nitrogen closed Brayton cycle for small modular sodium-cooled fast reactor studied. • Thermodynamic modelling and analysis of closed Brayton cycle performed. • Two-shaft configuration proposed and performance compared to single shaft. • Preliminary design of heat exchangers and turbomachinery carried out. - Abstract: Sodium-cooled fast reactor (SFR) is considered the most promising of the Generation IV reactors for their near-term demonstration of power generation. Small modular SFRs (SM-SFRs) have less investment risk, can be deployed more quickly, are easier to operate and are more flexible in comparison to large nuclear reactor. Currently, SFRs use the proven Rankine steam cycle as the power conversion system. However, a key challenge is to prevent dangerous sodium-water reaction that could happen in SFR coupled to steam cycle. Nitrogen gas is inert and does not react with sodium. Hence, intercooled closed Brayton cycle (CBC) using nitrogen as working fluid and with a single shaft configuration has been one common power conversion system option for possible near-term demonstration of SFR. In this work, a new two shaft nitrogen CBC with parallel turbines was proposed to further simplify the design of the turbomachinery and reduce turbomachinery size without compromising the cycle efficiency. Furthermore, thermodynamic performance analysis and preliminary design of components were carried out in comparison with a reference single shaft nitrogen cycle. Mathematical models in Matlab were developed for steady state thermodynamic analysis of the cycles and for preliminary design of the heat exchangers, turbines and compressors. Studies were performed to investigate the impact of the recuperator minimum terminal temperature difference (TTD) on the overall cycle efficiency and recuperator size. The effect of turbomachinery efficiencies on the overall cycle efficiency was examined. The results showed that the cycle efficiency of the proposed

  2. Feasible mathematics II

    CERN Document Server

    Remmel, Jeffrey

    1995-01-01

    Perspicuity is part of proof. If the process by means of which I get a result were not surveyable, I might indeed make a note that this number is what comes out - but what fact is this supposed to confirm for me? I don't know 'what is supposed to come out' . . . . 1 -L. Wittgenstein A feasible computation uses small resources on an abstract computa­ tion device, such as a 'lUring machine or boolean circuit. Feasible math­ ematics concerns the study of feasible computations, using combinatorics and logic, as well as the study of feasibly presented mathematical structures such as groups, algebras, and so on. This volume contains contributions to feasible mathematics in three areas: computational complexity theory, proof theory and algebra, with substantial overlap between different fields. In computational complexity theory, the polynomial time hierarchy is characterized without the introduction of runtime bounds by the closure of certain initial functions under safe composition, predicative recursion on nota...

  3. Temporary implantable nitinol device (TIND): a novel, minimally invasive treatment for relief of lower urinary tract symptoms (LUTS) related to benign prostatic hyperplasia (BPH): feasibility, safety and functional results at 1 year of follow-up.

    Science.gov (United States)

    Porpiglia, Francesco; Fiori, Cristian; Bertolo, Riccardo; Garrou, Diletta; Cattaneo, Giovanni; Amparore, Daniele

    2015-08-01

    To report the first clinical experience with a temporary implantable nitinol device (TIND; Medi-Tate(®) ) for the treatment of lower urinary tract symptoms (LUTS) due to benign prostatic hyperplasia (BPH). In all, 32 patients with LUTS were enrolled in this prospective study, which was approved by our Institutional Ethics Committee. Inclusion criteria were: age >50 years, International Prostate Symptom Score (IPSS) of ≥10, maximum urinary flow rate (Qmax ) of ≤12 mL/s, and prostate volume of BPH. TIND implantation is a feasible and safe minimally invasive option for the treatment of BPH-related LUTS. The functional results are encouraging and the treatment significantly improved patient QoL. Further studies are required to assess durability of TIND results and to optimise the indications of such a procedure. © 2014 The Authors BJU International © 2014 BJU International Published by John Wiley & Sons Ltd.

  4. The effects of intercooling and regeneration on the thermo-ecological performance analysis of an irreversible-closed Brayton heat engine with variable-temperature thermal reservoirs

    International Nuclear Information System (INIS)

    Sogut, Oguz Salim; Ust, Yasin; Sahin, Bahri

    2006-01-01

    A thermo-ecological performance analysis of an irreversible intercooled and regenerated closed Brayton heat engine exchanging heat with variable-temperature thermal reservoirs is presented. The effects of intercooling and regeneration are given special emphasis and investigated in detail. A comparative performance analysis considering the objective functions of an ecological coefficient of performance, an ecological function proposed by Angulo-Brown and power output is also carried out. The results indicate that the optimal total isentropic temperature ratio and intercooling isentropic temperature ratio at the maximum ecological coefficient of performance conditions (ECOP max ) are always less than those of at the maximum ecological function ( E-dot max ) and the maximum power output conditions ( W-dot max ) leading to a design that requires less investment cost. It is also concluded that a design at ECOP max conditions has the advantage of higher thermal efficiency and a lesser entropy generation rate, but at the cost of a slight power loss

  5. Modeling and sizing of the heat exchangers of a new supercritical CO2 Brayton power cycle for energy conversion for fusion reactors

    International Nuclear Information System (INIS)

    Serrano, I.P.; Cantizano, A.; Linares, J.I.; Moratilla, B.Y.

    2014-01-01

    Highlights: •We propose a procedure to model the heat exchangers of a S-CO2 Brayton power cycle. •Discretization in sub-heat exchangers is performed due to complex behavior of CO 2 . •Different correlations have been tested, verifying them with CFD when necessary. •Obtained sizes are agree with usual values of printed circuit heat exchangers. -- Abstract: TECNO F US is a research program financed by the Spanish Government to develop technologies related to a dual-coolant (He/Pb–Li) breeding blanket design concept including the auxiliary systems for a future power reactor (DEMO). One of the main issues of this program is the optimization of heat recovery from the reactor and its conversion into electrical power. This paper is focused on the methodology employed for the design and sizing of all the heat exchangers of the supercritical CO 2 Brayton power cycle (S-CO2) proposed by the authors. Due to the large pressure difference between the fluids, and also to their compactness, Printed Circuit Heat Exchangers (PCHE) are suggested in literature for these type of cycles. Because of the complex behavior of CO 2 , their design is performed by a numerical discretization into sub-heat exchangers, thus a higher precision is reached when the thermal properties of the fluids vary along the heat exchanger. Different empirical correlations for the pressure drop and the Nusselt number have been coupled and assessed. The design of the precooler (PC) and the low temperature recuperator (LTR) is also verified by simulations using CFD because of the near-critical behavior of CO 2 . The size of all of the heat exchangers of the cycle have been assessed

  6. Modeling and sizing of the heat exchangers of a new supercritical CO{sub 2} Brayton power cycle for energy conversion for fusion reactors

    Energy Technology Data Exchange (ETDEWEB)

    Serrano, I.P.; Cantizano, A.; Linares, J.I., E-mail: linares@upcomillas.es; Moratilla, B.Y.

    2014-10-15

    Highlights: •We propose a procedure to model the heat exchangers of a S-CO2 Brayton power cycle. •Discretization in sub-heat exchangers is performed due to complex behavior of CO{sub 2}. •Different correlations have been tested, verifying them with CFD when necessary. •Obtained sizes are agree with usual values of printed circuit heat exchangers. -- Abstract: TECNO{sub F}US is a research program financed by the Spanish Government to develop technologies related to a dual-coolant (He/Pb–Li) breeding blanket design concept including the auxiliary systems for a future power reactor (DEMO). One of the main issues of this program is the optimization of heat recovery from the reactor and its conversion into electrical power. This paper is focused on the methodology employed for the design and sizing of all the heat exchangers of the supercritical CO{sub 2} Brayton power cycle (S-CO2) proposed by the authors. Due to the large pressure difference between the fluids, and also to their compactness, Printed Circuit Heat Exchangers (PCHE) are suggested in literature for these type of cycles. Because of the complex behavior of CO{sub 2}, their design is performed by a numerical discretization into sub-heat exchangers, thus a higher precision is reached when the thermal properties of the fluids vary along the heat exchanger. Different empirical correlations for the pressure drop and the Nusselt number have been coupled and assessed. The design of the precooler (PC) and the low temperature recuperator (LTR) is also verified by simulations using CFD because of the near-critical behavior of CO{sub 2}. The size of all of the heat exchangers of the cycle have been assessed.

  7. Optimizing an advanced hybrid of solar-assisted supercritical CO2 Brayton cycle: A vital transition for low-carbon power generation industry

    International Nuclear Information System (INIS)

    Milani, Dia; Luu, Minh Tri; McNaughton, Robbie; Abbas, Ali

    2017-01-01

    Highlights: • The layout of 14 demonstrative supercritical CO 2 closed Brayton cycles are analysed. • The key parameters of the “combined” cycle are sensitized and optimized. • The effect of thermal efficiency vs HX area on techno-economic nexus is highlighted. • The design of a matching solar heliostat field in direct configuration is revealed. • The water demand for hybrid vs water-only cooling scenarios are assessed. - Abstract: Current worldwide infrastructure of electrical power generation would mostly continue to rely on fossil-fuel but require a modest transition for the ultimate goal of decarbonizing power generation industry. By relying on those already established and carefully managed centrepiece power plants (PPs), we aim at filling the deficits of the current electrical networks with smaller, cleaner, and also more efficient PPs. In this context, we present a unique model for a small-scale decentralized solar-assisted supercritical CO 2 closed Brayton cycle (sCO 2 -CBC). Our model is based on the optimized values of three key performance indicators (KPIs); thermal efficiency, concentrated solar power (CSP) compatibility, and water demand for cooling. For a case-study of 10 MW e CSP-assisted sCO 2 -CBC power plant, our dynamic model shows a 52.7% thermal efficiency and 25.9% solar penetration and up to 80% of water saving in heat-rejection units. These KPIs show significant promise of the solar-assisted supercritical CO 2 power cycle for an imperative transformation in the power industry towards future sustainable electricity generation.

  8. A phase I/II trial to evaluate the safety, feasibility and activity of salvage therapy consisting of the mTOR inhibitor Temsirolimus added to standard therapy of Rituximab and DHAP for the treatment of patients with relapsed or refractory diffuse large cell B-Cell lymphoma – the STORM trial

    International Nuclear Information System (INIS)

    Witzens-Harig, Mathias; Memmer, Marie Luise; Dreyling, Martin; Hess, Georg

    2013-01-01

    The current standard treatment of patients with relapsed or refractory diffuse large cell B-Cell lymphoma (DLBCL) primarily consists of intensified salvage therapy and, if the disease is chemo-sensitive, high dose therapy followed with autologous stem cell transplantation. In the rituximab era however, this treatment approach has shown only limited benefit. In particular, patients relapsing after rituximab-containing primary treatment have an adverse prognosis, especially if this occurs within the first year after therapy or if the disease is primarily refractory. Therefore there is an ultimate need for improved salvage treatment approaches. The STORM study is a prospective, multicentre phase I/II study to evaluate the safety, feasibility and activity of salvage therapy consisting of the mTOR inhibitor temsirolimus added to the standard therapy rituximab and DHAP for the treatment of patients with relapsed or refractory DLBCL. The primary objective of the phase I of the trial is to establish the maximum tolerated dose (MTD) of temsirolimus in combination with rituximab and DHAP. The secondary objective is to demonstrate that stem cells can be mobilized during this regimen in patients scheduled to proceed to high dose therapy. In phase II, the previously established maximum tolerated dose of temsirolimus will be used. The primary objective is to evaluate the overall response rate (ORR) in patients with relapsed DLBCL. The secondary objective is to evaluate progression free survival (PFS), overall survival (OS) and toxicity. The study will be accompanied by an analysis of lymphoma subtypes determined by gene expression analysis (GEP). The STORM trial evaluates the safety, feasibility and activity of salvage therapy consisting of the mTOR inhibitor temsirolimus added to standard therapy of rituximab and DHAP for the treatment of patients with relapsed or refractory DLBCL. It also might identify predictive markers for this treatment modality. ClinicalTrials.gov http

  9. Auto Safety

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Auto Safety KidsHealth / For Parents / Auto Safety What's in this ... by teaching some basic rules. Importance of Child Safety Seats Using a child safety seat (car seat) ...

  10. Radiation processing of flue gases: Guidelines for feasibility studies

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-12-01

    The aim of this publication is to facilitate the performance of feasibility studies for Electron Beam flue gas cleanup projects by providing guidelines to conduct these studies and compiling information on the state of the art. This document summarizes the contents of a feasibility study; discusses the main items in plant construction, measurement and control systems, radiation safety and building construction; and lists the required economic data for internationally funded projects.

  11. Radiation processing of flue gases: Guidelines for feasibility studies

    International Nuclear Information System (INIS)

    2000-12-01

    The aim of this publication is to facilitate the performance of feasibility studies for Electron Beam flue gas cleanup projects by providing guidelines to conduct these studies and compiling information on the state of the art. This document summarizes the contents of a feasibility study; discusses the main items in plant construction, measurement and control systems, radiation safety and building construction; and lists the required economic data for internationally funded projects

  12. Feasibility of protein-sparing modified fast by tube (ProMoFasT) in obesity treatment: a phase II pilot trial on clinical safety and efficacy (appetite control, body composition, muscular strength, metabolic pattern, pulmonary function test).

    Science.gov (United States)

    Sukkar, S G; Signori, A; Borrini, C; Barisione, G; Ivaldi, C; Romeo, C; Gradaschi, R; Machello, N; Nanetti, E; Vaccaro, A L

    2013-01-01

    Anecdotal data in the last few years suggest that protein-sparing modified diet (PSMF) delivered by naso-gastric tube enteral (with continuous feeding) could attain an significant weight loss and control of appetite oral feeding, but no phase II studies on safety and efficacy have been done up to now. To verify the safety and efficacy of a protein-sparing modified fast administered by naso-gastric tube (ProMoFasT) for 10 days followed by 20 days of a low-calorie diet, in patients with morbid obesity (appetite control, fat free mass maintenance, pulmonary function tests and metabolic pattern, side effects), 26 patients with a BMI ≥30 kg/m 2 have been selected. The patients had to follow a protein-sparing fast by enteral nutrition (ProMoFasT) for 24 h/day, for 10 days followed by 20 days of low-calorie diet (LCD). The endpoint was represented by body weight, BMI, abdominal circumference, Haber's appetite test, body composition by body impedance assessment (BIA), handgrip strength test, metabolic pattern, pulmonary function test. Safety was assessed by evaluation of complications and side effects of PSMF and/or enteral nutrition. In this report the results on safety and efficacy are described after 10 and 30 days of treatment. After the recruiting phase, a total of 22 patients out of 26 enrolled [14 (63.6 %) females] were evaluated in this study. Globally almost all clinical parameters changed significantly during first 10 days. Total body weight significantly decreased after 10 days (∆-6.1 ± 2; p  < 0.001) and this decrease is maintained in the following 20 days of LCD (∆ = -5.88 ± 1.79; p  < 0.001). Also the abdominal circumference significantly decreased after 10 days [median (range): -4.5 (-30 to 0); p  < 0.001] maintained then in the following 20 days of LCD [median (range) = -7 (-23.5 to -2); p  < 0.001]. All BIA parameters significantly changed after 10 and 30 days from baseline. All parameters except BF had a significant

  13. Subseabed disposal safety analysis

    International Nuclear Information System (INIS)

    Koplick, C.M.; Kabele, T.J.

    1982-01-01

    This report summarizes the status of work performed by Analytic Sciences Corporation (TASC) in FY'81 on subseabed disposal safety analysis. Safety analysis for subseabed disposal is divided into two phases: pre-emplacement which includes all transportation, handling, and emplacement activities; and long-term (post-emplacement), which is concerned with the potential hazard after waste is safely emplaced. Details of TASC work in these two areas are provided in two technical reports. The work to date, while preliminary, supports the technical and environmental feasibility of subseabed disposal of HLW

  14. Safety review advisor

    International Nuclear Information System (INIS)

    Boshers, J.A.; Uhrig, R.E.; Alguindigue, I.A.; Burnett, C.G.

    1991-01-01

    The University of Tennessee's Nuclear Engineering department, in cooperation with the Tennessee Valley Authority (TVA), is evaluating the feasibility of utilizing an expert system to aid in 10CFR50.59 evaluations. This paper discusses the history of 10CFR50.59 reviews, and details the development approach used in the construction of a prototype Safety Review Advisor (SRA). The goals for this expert system prototype are to aid the engineer in the evaluation process by directing his attention to the appropriate critical issues, increase the efficiency, consistency, and thoroughness of the evaluation process, and provide a foundation of appropriate Safety Analysis Report (SAR) references for the reviewer

  15. Feasibility studies and technological innovation

    DEFF Research Database (Denmark)

    Hvelplund, Frede Kloster; Lund, Henrik; Sukkumnoed, Decharut

    2004-01-01

    The chapter offers a tool to conduct feasibility studies and focuses on how to make feasibility studies in a situation with environmental concerns, in which technological innovation and institutional chnages are among the objectives.......The chapter offers a tool to conduct feasibility studies and focuses on how to make feasibility studies in a situation with environmental concerns, in which technological innovation and institutional chnages are among the objectives....

  16. PWR decontamination feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Silliman, P.L.

    1978-12-18

    The decontamination work which has been accomplished is reviewed and it is concluded that it is worthwhile to investigate further four methods for decontamination for future demonstration. These are: dilute chemical; single stage strong chemical; redox processes; and redox/chemical in combination. Laboratory work is recommended to define the agents and processes for demonstration and to determine the effect of the solvents on PWR materials. The feasibility of Indian Point 1 for decontamination demonstrations is discussed, and it is shown that the system components of