WorldWideScience

Sample records for bracket base conditioning

  1. Shear bond strength of orthodontic brackets to enamel under different surface treatment conditions

    Directory of Open Access Journals (Sweden)

    Matheus Melo Pithon

    2007-04-01

    Full Text Available The purpose of the present study was to evaluate the shear bond strength to enamel and the adhesive remnant index (ARI of both metallic and polycarbonate brackets bonded under different conditions. Ninety bovine permanent mandibular incisors were embedded in acrylic resin using PVC rings as molds and assigned to 6 groups (n=15. In Groups 1 (control and 3, metallic and polycarbonate orthodontic brackets were, respectively, bonded to the enamel surfaces using Transbond XT composite according to the manufacturer's recommendations. In Groups 2 and 4, both types of brackets were bonded to enamel with Transbond XT composite, but XT primer was replaced by the OrthoPrimer agent. In Groups 5 and 6, the polycarbonate bracket bases were sandblasted with 50-mm aluminum-oxide particle stream and bonded to the enamel surfaces prepared under the same conditions described in Groups 3 and 4, respectively. After bonding, the specimens were stored in distilled water at 37ºC for 24 hours and then submitted to shear bond strength test at a crosshead speed of 0.5 mm/min. The results (MPa showed no statistically significant difference between Groups 4 and 6 (p>0.05. Likewise, no statistically significant differences (p>0.05 were found among Groups 1, 2, and 5, although their results were significantly lower than those of Groups 4 and 6 (p<0.05. Group 3 had statistically significant lower bond strength than Groups 2, 4, and 6, but no statistically significant differences were found on comparison to Groups 1 and 5. A larger number of fractures at the bracket/composite interface were evidenced by the ARI scores. OrthoPrimer bonding agent yielded higher bond strength in the groups using either conventional or sandblasted polycarbonate brackets, which was not observed in the groups using metallic brackets.

  2. Evaluation of failure characteristics and bond strength after ceramic and polycarbonate bracket debonding: effect of bracket base silanization.

    Science.gov (United States)

    Ozcan, M; Finnema, K; Ybema, A

    2008-04-01

    The objectives of this study were to evaluate the effect of silanization on the failure type and shear-peel bond strength (SBS) of ceramic and polycarbonate brackets, and to determine the type of failure when debonded with either a universal testing machine or orthodontic pliers. Silanized and non-silanized ceramic and polycarbonate brackets (N = 48, n = 24 per bracket type) were bonded to extracted caries-free human maxillary central incisors using an alignment apparatus under a weight of 750 g. All bonded specimens were thermocycled 1000 times (5-55 degrees C). Half of the specimens from each group were debonded with a universal testing machine (1 mm/minute) to determine the SBS and the other half by an operator using orthodontic debonding pliers. Failure types of the enamel surface and the bracket base were identified both from visual inspection and digital photographs using the adhesive remnant index (ARI) and base remnant index (BRI). As-received ceramic brackets showed significantly higher bond strength values (11.5 +/- 4.1 MPa) than polycarbonate brackets [6.3 +/- 2.7 MPa; (P = 0.0077; analysis of variance (ANOVA)]. Interaction between bracket types and silanization was not significant (P = 0.4408). Silanization did not significantly improve the mean SBS results either for the ceramic or polycarbonate brackets (12.9 +/- 3.7 and 6.3 +/- 2.7 MPa, respectively; P = 0.4044; two-way ANOVA, Tukey-Kramer adjustment). There was a significant difference between groups in ARI scores for ceramic (P = 0.0991) but not polycarbonate (P = 0.3916; Kruskall-Wallis) brackets. BRI values did not vary significantly for ceramic (P = 0.1476) or polycarbonate (P = 0.0227) brackets. Failure type was not significantly different when brackets were debonded with a universal testing machine or with orthodontic debonding pliers. No enamel damage was observed in any of the groups.

  3. In vitro Evaluation of Microleakage of Orthodontic Brackets Bonded Using Methacrylate and Silorane Base Composite

    Directory of Open Access Journals (Sweden)

    AR Davari

    2015-09-01

    Conclusions: The results of the current relealed that silorane-bass silorane-base composite provided low microleakage for orthodontic brackets, for this reason, it could be used it for bonding brackets.

  4. COMPARISON OF THE SHEAR BOND STRENGTH OF BRACKETS USING TWO SURFACE CONDITIONING METHODS FOR PORCELAIN

    OpenAIRE

    Ballesteros-Pinzón, Claudia; Bermúdez-Lozano, Jesús A.; Coronel-Corzo, Nelly; de-León-Goenaga, Edwin; Delgado, Linda P.; Báez-Quintero, Liliana

    2014-01-01

    Introduction: During 2010 the degree research “Comparison of the shear bond strength of brackets using two surface conditioning methods for porcelain” was carried out at Universidad Cooperativa de Colombia in Bogota. Objective: To determine the shear bond strength of metal brackets cemented on porcelain using two surface conditioning methods. Materials and methods: Forty human premolars were used and prepared for further cementing porcelain-metal crowns. There were two groups of 20 teeth each...

  5. Effect of different methods of enamel conditioning on bond strength of orthodontic brackets

    Directory of Open Access Journals (Sweden)

    Davari AR

    2007-01-01

    Full Text Available Background and Aim: With the introduction of different bondable restorative materials in dentistry, various methods have been suggested to enhance the polymerization and shear bond strength of these materials. The aim of this study was to determine the effects of different methods of enamel conditioning on bond strength of orthodontic brackets and on the bracket/ adhesive failure mode. Materials and Methods: In this experimental in vitro study, brackets were bonded to thirty-six bovine incisor teeth with different protocols according to the manufacturer's instructions as follows: Group 1: conventional multistep adhesive (n=12; Group 2: self-etching primer system (n=12; Group 3: acid+self-etching primer system (n=12. Specimens were loaded in a universal testing machine (Instron, Canton and Mass and the mode of failure was recorded. Data were analyzed by ANOVA and Kruskall-Wallis tests with p<0.05 as the limit of significance. Results: The mean shear bond strength was 11.7 ± 4.2, 10.5 ± 4.4, and 10.9 ± 4.8 MPa for group 1, 2, and 3 respectively. There was no significant difference in bond strength among the three groups (P=0.800. No significant difference was observed among the three groups with respect to residual adhesive on the enamel surfaces (P=0.554. Conclusion: Based on the results of the present study, the use of self-etching primers may be an alternative to conventional phosphoric acid pre-treatment in orthodontic bonding.

  6. The Influence of No-Primer Adhesives and Anchor Pylons Bracket Bases on Shear Bond Strength of Orthodontic Brackets

    Directory of Open Access Journals (Sweden)

    Andrea Scribante

    2013-01-01

    Full Text Available Objective. The aim of this study was to compare the shear bond strength (SBS and adhesive remnant index (ARI scores of no-primer adhesives tested with two different bracket bases. Materials and Methods. 120 bovine permanent mandibular incisors were divided into 6 groups of 20 specimens. Two brackets (ODP with different bracket bases (anchor pylons and 80-gauge mesh were bonded to the teeth using a conventional adhesive (Transbond XT and two different no-primer adhesive (Ortho Cem; Heliosit systems. Groups were tested using an instron universal testing machine. SBS values were recorded. ARI scores were measured. SEM microphotographs were taken to evaluate the pattern of bracket bases. Statistical analysis was performed. ANOVA and Tukey tests were carried out for SBS values, whereas a chi-squared test was applied for ARI scores. Results. Highest bond strength values were reported with Transbond XT (with both pad designs, Ortho Cem bonded on anchor pylons and Heliosit on 80-gauge mesh. A higher frequency of ARI score of “3” was reported for Transbond XT groups. Other groups showed a higher frequency of ARI score “2” and “1.” Conclusion. Transbond XT showed the highest shear bond strength values with both pad designs.

  7. Effect of alloy type and surface conditioning on roughness and bond strength of metal brackets

    NARCIS (Netherlands)

    Nergiz, I.; Schmage, P.; Herrmann, W.; Ozcan, M.; Nergiz, [No Value

    2004-01-01

    The effect of 5 different surface conditioning methods on bonding of metal brackets to cast dental alloys was examined. The surface conditioning methods were fine (30-µm) or rough (125-µm) diamond bur, sandblasting (50-µm or 110-µm aluminum oxide [Al2O3]), and silica coating (30-µm silica). Fifty

  8. Effect of alloy type and surface conditioning on roughness and bond strength of metal brackets

    NARCIS (Netherlands)

    Nergiz, I.; Schmage, P.; Herrmann, W.; Ozcan, M.; Nergiz, [No Value

    2004-01-01

    The effect of 5 different surface conditioning methods on bonding of metal brackets to cast dental alloys was examined. The surface conditioning methods were fine (30-µm) or rough (125-µm) diamond bur, sandblasting (50-µm or 110-µm aluminum oxide [Al2O3]), and silica coating (30-µm silica). Fifty di

  9. Shear Bond Strength of Bracket Bases to Adhesives Based on Bracket Base Design

    Science.gov (United States)

    2016-04-13

    in vitro comparison with foil-mesh. European Journal of Orthodontics 1989; 11:144- 153. Retief, DH.; Sadowsky, PL. Clinical experience with the...strength that is clinically acceptable for performing orthodontics (Reynolds 1975). Modern orthodontic shear bond strength studies generally report bond...bases, in addition to their claimed equal or superior bond strengths with traditional mesh bases, become important in both clinical orthodontics and

  10. Breket titanium (Titanium bracket

    Directory of Open Access Journals (Sweden)

    Sianiwati Goenharto

    2005-09-01

    Full Text Available There has been a considerable discussion in the literature about corrosion and sensitivity to the nickel present in stainless steel brackets. Titanium has been heralded as a material totally compatible in the oral environment and superior in structural integrity compared to stainless steel. Many current applications in dentistry and medicine have made titanium an obvious choice for a possible substitute material. Titanium based brackets have shown excellent corrosion resistance and possessed good biocompatibility. Evaluation of titanium brackets for orthodontic therapy showed that titanium brackets were comparable to stainless steel brackets in passive and active configuration. Study about metallographic structure, hardness, bond strength to enamel substrate, etc. showed that titanium brackets exhibited a potential for clinical application. It was concluded that titanium brackets were suitable substitute for stainless steel brackets.

  11. Effects of silica coating and silane surface conditioning on the bond strength of rebonded metal and ceramic brackets

    Directory of Open Access Journals (Sweden)

    Saadet Atsü

    2011-06-01

    Full Text Available OBJECTIVE: The aim of this study was to evaluate the effects of tribochemical silica coating and silane surface conditioning on the bond strength of rebonded metal and ceramic brackets. MATERIAL AND METHODS: Twenty debonded metal and 20 debonded ceramic brackets were randomly assigned to receive one of the following surface treatments (n=10 for each group: (1 sandblasting (control; (2 tribochemical silica coating combined with silane. Brackets were rebonded to the enamel surface on the labial and lingual sides of premolars with a light-polymerized resin composite. All specimens were stored in distilled water for 1 week and then thermocycled (5,000 cycles between 5-55ºC. Shear bond strength values were measured using a universal testing machine. Student's t-test was used to compare the data (α=0.05. Failure mode was assessed using a stereomicroscope, and the treated and non-treated bracket surfaces were observed by scanning electron microscopy. RESULTS: Rebonded ceramic brackets treated with silica coating followed by silanization had significantly greater bond strength values (17.7±4.4 MPa than the sandblasting group (2.4±0.8 MPa, P<0.001. No significant difference was observed between the rebonded metal brackets treated with silica coating with silanization (15±3.9 MPa and the sandblasted brackets (13.6±3.9 MPa. Treated rebonded ceramic specimens primarily exhibited cohesive failure in resin and adhesive failure at the enamel-adhesive interface. CONCLUSIONS: In comparison to sandblasting, silica coating with aluminum trioxide particles followed by silanization resulted in higher bond strengths of rebonded ceramic brackets.

  12. CO2 laser conditioning of porcelain surfaces for bonding metal orthodontic brackets.

    Science.gov (United States)

    Ahrari, Farzaneh; Heravi, Farzin; Hosseini, Mohsen

    2013-07-01

    Bonding to porcelain remains to be a challenge in orthodontic treatments. The objective of this study was to evaluate the effect of CO2 laser conditioning of porcelain surfaces on shear bond strength (SBS) of orthodontic brackets. Eighty feldspathic porcelain specimens were divided into four groups of 20. In each group, half of the porcelain surfaces were deglazed, while the others remained glazed. The specimens in groups 1 to 3 were treated with a fractional CO2 laser for 10 s using 10 mJ of energy, frequency of 200 Hz and powers of 10 W (group 1), 15 W (group 2) and 20 W (group 3). In group 4, a 9.6 % hydrofluoric (HF) acid gel was used for 2 min. A silane coupling agent was applied before bracket bonding, and the SBS was measured with a universal testing machine after 24 h. Deglazing caused significant increase in SBS of laser treated porcelain surfaces (p porcelain.

  13. Shear Bond Strength of Ceramic Brackets with Different Base Designs: Comparative In-vitro Study

    Science.gov (United States)

    Ansari, Mohd. Younus; Agarwal, Deepak K; Bhattacharya, Preeti; Ansar, Juhi; Bhandari, Ravi

    2016-01-01

    Introduction Knowledge about the Shear Bond Strength (SBS) of ceramic brackets with different base design is essential as it affects bond strength to enamel. Aim The aim of the present study was to evaluate and compare the effect of base designs of different ceramic brackets on SBS, and to determine the fracture site after debonding. Materials and Methods Four groups of ceramic brackets and one group of metal brackets with different base designs were used. Adhesive precoated base of Clarity Advanced (APC Flash-free) (Unitek/3M, Monrovia, California), microcrystalline base of Clarity Advanced (Unitek/3M, Monrovia, California), polymer mesh base of InVu (TP Orthodontics, Inc., La Porte, IN, United States), patented bead ball base of Inspire Ice (Ormco, Glendora, California), and a mechanical mesh base of Gemini Metal bracket (Unitek/3M, Monrovia, California). Ten brackets of each type were bonded to 50 maxillary premolars with Transbond XT (Unitek/3M). Samples were stored in distilled water at room temperature for 24 hours and subsequently tested in shear mode on a universal testing machine (Model 3382; Instron Corp., Canton, Massachusetts, USA) at a cross head speed of 1mm/minute with the help of a chisel. The debonded interface was recorded and analyzed to determine the predominant bond failure site under an optical microscope (Stereomicroscope) at 10X magnification. One way analysis of variance (ANOVA) was used to compare SBS. Tukey’s significant differences tests were used for post-hoc comparisons. The Adhesive Remnant Index (ARI) scores were compared by chi-square test. Results Mean SBS of microcrystalline base (27.26±1.73), was the highest followed by bead ball base (23.45±5.09), adhesive precoated base (20.13±5.20), polymer mesh base (17.54±1.91), and mechanical mesh base (17.50±2.41) the least. Comparing the frequency (%) of ARI Score among the groups, chi-square test showed significantly different ARI scores among the groups (χ2 = 34.07, p<0

  14. Evaluation of failure characteristics and bond strength after ceramic and polycarbonate bracket debonding : effect of bracket base silanization

    NARCIS (Netherlands)

    Ozcan, M.; Finnema, K.; Ybema, A.

    2008-01-01

    The objectives of this study were to evaluate the effect of silanization on the failure type and shear-peel bond strength (SBS) of ceramic and polycarbonate brackets, and to determine the type of failure when debonded with either a universal testing machine or orthodontic pliers. Silanized and non-s

  15. The Effect of Bracket Base Pylon Orientation on the Shear Bond Strength of the ODP ANCHOR-LOCK Bracket Pad

    Science.gov (United States)

    2013-06-06

    directly to enamel without the need for additional bonding agents and surface treatments (Millet and McCabe, 1996). The primary mechanism for adhesion is...the adhesive surface than enamel would have during shear force application. The shapes and orientation of the brackets were not identical. Minor...that occurs while removing orthodontic adhesive with carbide burs is only 7.4 um, great care must be taken to avoid excessive damage to the enamel

  16. Occurrence and severity of enamel decalcification adjacent to bracket bases and sub-bracket lesions during orthodontic treatment with two different lingual appliances

    Science.gov (United States)

    Klang, Elisabeth; Helms, Hans-Joachim; Wiechmann, Dirk

    2016-01-01

    Summary Background: Using lingual enamel surfaces for bracket placement not only has esthetic advantages, but may also be suitable in terms of reducing frequencies of enamel decalcifications. Objective: To test the null-hypothesis that there is no significant difference in enamel decalcification or cavitation incidence adjacent to and beneath bracket bases between two lingual multi-bracket (MB) appliances that are different in terms of design, material composition, and manufacturing technology (group A: WIN, DW-LingualSystems; group B: Incognito, 3M-Unitek), taking into account patient- and treatment-related variables on white spot lesion (WSL) formation. Methods: Standardized, digital, top-view photographs of 630 consecutive subjects (16214 teeth; n Incognito = 237/6076 teeth; n WIN = 393/10138 teeth; mean age: 17.47±7.8; m/f 43.2/56.8%) with completed lingual MB treatment of the upper and lower permanent teeth 1–7 were screened for decalcification or cavitation adjacent to and beneath the bracket bases before and after treatment, scored from 0 to 7. Non-parametric ANOVA was used for main effects ‘appliance type’, ‘gender’, ‘treatment complexity’, ‘grouped age’ (≤16/>16 years), and ‘treatment duration’ as covariable, at an α-level of 5%. Results: About 2.57% [5.94%] of all teeth in group A [B] developed decalcifications. Subject-related incidence was 9.59% [16.17%] for upper incisors in group A [B], and 12.98% [25.74%] for all teeth 16–46. There were significant effects by gender, age, and treatment duration. Conclusion: The null-hypothesis was rejected: sub-bracket lesions were significantly less frequent in group A, while frequencies of WSL adjacent to brackets were not significantly affected by appliance type. In view of the overall low incidences of lingual post-orthodontic white-spot lesions, the use of lingual appliances is advocated as a valid strategy for a reduction of enamel decalcifications during orthodontic treatment. PMID

  17. Influence of various surface-conditioning methods on the bond strength of metal brackets to ceramic surfaces.

    Science.gov (United States)

    Schmage, Petra; Nergiz, Ibrahim; Herrmann, Wolfram; Ozcan, Mutlu

    2003-05-01

    With the increase in adult orthodontic treatment comes the need to find a reliable method for bonding orthodontic brackets onto metal or ceramic crowns and fixed partial dentures. In this study, shear bond strength and surface roughness tests were used to examine the effect of 4 different surface conditioning methods: fine diamond bur, sandblasting, 5% hydrofluoric acid, and silica coating for bonding metal brackets to ceramic surfaces of feldspathic porcelain. Sandblasting and hydrofluoric acid were further tested after silane application. A total of 120 ceramic disc samples were produced, and 50 were used for surface roughness measurements. The glazed ceramic surfaces were used as controls. Metal brackets were bonded to the ceramic substrates with a self-curing composite. The samples were stored in 0.9% NaCl solution for 24 hours and then thermocycled (5000 times, 5 degrees C to 55 degrees C, 30 seconds). Shear bond tests were performed with a universal testing device, and the results were statistically analyzed. Chemical surface conditioning with either hydrofluoric acid (4.3 microm) or silicatization (4.4 microm) resulted in significantly lower surface roughness than mechanical conditioning (9.3 microm, diamond bur; 9.7 microm, sandblasting) (P <.001). The surface roughness values reflect the mean peak-and-valley distances. The bond strengths of the brackets bonded to the ceramic surfaces treated by hydrofluoric acid with and without silane (12.2 and 14.7 MPa, respectively), silicatization (14.9 MPa), and sandblasting with silane (15.8 MPa) were significantly higher (P <.001) than those treated by mechanical roughening with fine diamond burs (1.6 MPa) or sandblasting (2.8 MPa). The highest bond strength values were obtained with sandblasting and silicatization with silane or hydrofluoric acid without silane; these fulfilled the required threshold. The use of silane after hydrofluoric acid etching did not increase the bond strength. Diamond roughening and

  18. Optimization of a procedure for rebonding dislodged orthodontic brackets.

    Science.gov (United States)

    Mui, B; Rossouw, P E; Kulkarni, G V

    1999-06-01

    The purpose of this study was to compare shear bond strength (SBS) of bonded and rebonded orthodontic brackets following a variety of commonly used conditioning treatments and using both light-cured and self-cured composite resin systems. Brackets debonded during the initial determination of SBS were rebonded after the removal of residual resin from enamel surfaces using five different treatments: (1) Remove residual resin using a tungsten carbide bur, re-etch enamel surface, then bond a new bracket; (2) Remove resin from the base mesh with micro-etching then rebond the same bracket, (3) Remove residual resin from the enamel surface using resin-removing pliers, recondition the enamel with an air-powder polisher, then bond a new bracket; (4) Remove residual resin using a rubber cup and pumice, then bond a new bracket; (5) Remove residual resin using pliers alone, then bond a new bracket. The results revealed that the light-cured system produced higher shear bond strength in the initial bond than the self-cured system (ptungsten carbide bur and acid-etching gave the highest SBS (difference 5.8 MPa; pfracture characteristics. The data suggest that the optimal procedure for rebonding dislodged orthodontic brackets is to resurface the enamel using a tungsten carbide bur, acid-etch the enamel, and use a new or re-use an old bracket after microetching.

  19. Tensile Bond Strength of Metal Bracket Bonding to Glazed Ceramic Surfaces With Different Surface Conditionings

    Directory of Open Access Journals (Sweden)

    M. Imani

    2011-12-01

    Full Text Available Objective: The objective of this study was to compare the tensile bond strength of metal brackets bonding to glazed ceramic surfaces using three various surface treatments.Materials and Methods: Forty two glazed ceramic disks were assigned to three groups. In the first and second groups the specimens were etched with 9.5% hydrofluoric acid (HFA. Subsequently in first group, ceramic primer and adhesive were applied, but in second group a bonding agent alone was used. In third group, specimens were treated with 35% phosphoric acid followed by ceramic primerand adhesive application. Brackets were bonded with light cure composites. The specimens were stored in distilled water in the room temperature for 24 hours and thermocycled 500 times between 5°C and 55°C. The universal testing machine was used to test the tensile bond strength and the adhesive remenant index scores between three groups was evaluated. The data were subjected to one-way ANOVA, Tukey and Kruskal-Wallis tests respectively.Results: The tensile bond strength was 3.69±0.52 MPa forfirst group, 2.69±0.91 MPa for second group and 3.60±0.41 MPa for third group. Group II specimens showed tensile strength values significantly different from other groups (P<0.01.Conclusion: In spite of limitations in laboratory studies it may be concluded that in application of Scotch bond multipurpose plus adhesive, phosphoric acid can be used instead of HFA for bonding brackets to the glazed ceramic restorations with enough tensile bond strength.

  20. Effects of surface-conditioning methods on shear bond strength of brackets bonded to different all-ceramic materials.

    Science.gov (United States)

    Saraç, Y Şinasi; Külünk, Tolga; Elekdağ-Türk, Selma; Saraç, Duygu; Türk, Tamer

    2011-12-01

    The aims of this study were to investigate the effects of two surface-conditioning methods on the shear bond strength (SBS) of metal brackets bonded to three different all-ceramic materials, and to evaluate the mode of failure after debonding. Twenty feldspathic, 20 fluoro-apatite, and 20 leucite-reinforced ceramic specimens were examined following two surface-conditioning methods: air-particle abrasion (APA) with 25 μm Al(2)O(3) and silica coating with 30 μm Al(2)O(3) particles modified by silica. After silane application, metal brackets were bonded with light cure composite and then stored in distilled water for 1 week and thermocycled (×1000 at 5-55°C for 30 seconds). The SBS of the brackets was measured on a universal testing machine. The ceramic surfaces were examined with a stereomicroscope to determine the amount of composite resin remaining using the adhesive remnant index. Two-way analysis of variance, Tukey's multiple comparison test, and Weibull analysis were used for evaluation of SBS. The lowest SBS was with APA for the fluoro-apatite ceramic (11.82 MPa), which was not significantly different from APA for the feldspathic ceramic (13.58 MPa). The SBS for the fluoro-apatite ceramic was significantly lower than that of leucite-reinforced ceramic with APA (14.82 MPa). The highest SBS value was obtained with silica coating of the leucite-reinforced ceramic (24.17 MPa), but this was not significantly different from the SBS for feldspathic and fluoro-apatite ceramic (23.51 and 22.18 MPa, respectively). The SBS values with silica coating showed significant differences from those of APA. For all samples, the adhesive failures were between the ceramic and composite resin. No ceramic fractures or cracks were observed. Chairside tribochemical silica coating significantly increased the mean bond strength values.

  1. Frictional and mechanical properties of diamond-like carbon-coated orthodontic brackets.

    Science.gov (United States)

    Muguruma, Takeshi; Iijima, Masahiro; Brantley, William A; Nakagaki, Susumu; Endo, Kazuhiko; Mizoguchi, Itaru

    2013-04-01

    This study investigated the effects of a diamond-like carbon (DLC) coating on frictional and mechanical properties of orthodontic brackets. DLC films were deposited on stainless steel brackets using the plasma-based ion implantation/deposition (PBIID) method under two different atmospheric conditions. As-received metal brackets served as the control. Two sizes of stainless steel archwires, 0.018 inch diameter and 0.017 × 0.025 inch cross-section dimensions, were used for measuring static and kinetic friction by drawing the archwires through the bracket slots, using a mechanical testing machine (n = 10). The DLC-coated brackets were observed with a scanning electron microscope (SEM). Values of hardness and elastic modulus were obtained by nanoindentation testing (n = 10). Friction forces were compared by one-way analysis of variance and the Scheffé test. The hardness and elastic modulus of the brackets were compared using Kruskal-Wallis and Mann-Whitney U-tests. SEM photomicrographs showed DLC layers on the bracket surfaces with thickness of approximately 5-7 μm. DLC-coated brackets deposited under condition 2 showed significantly less static frictional force for the stainless steel wire with 0.017 × 0.025 inch cross-section dimensions than as-received brackets and DLC-coated brackets deposited under condition 1, although both DLC-coated brackets showed significantly less kinetic frictional force than as-received brackets. The hardness of the DLC layers was much higher than that of the as-received bracket surfaces. In conclusion, the surfaces of metal brackets can be successfully modified by the PBIID method to create a DLC layer, and the DLC-coating process significantly reduces frictional forces.

  2. Comparative study of friction between metallic and conventional interactive self-ligating brackets in different alignment conditions

    OpenAIRE

    Jakob,Sérgio Ricardo; Matheus, Davison; Jimenez-Pellegrin, Maria Cristina; Turssi, Cecília Pedroso; do Amaral, Flávia Lucisano Botelho

    2014-01-01

    Objective The aim of this study was to compare the friction between three bracket models: conventional stainless steel (Ovation, Dentsply GAC), self-ligating ceramic (In-Ovation, Denstply GAC) and self-ligating stainless steel brackets (In-Ovation R, Dentsply GAC). Methods Five brackets were used for each model. They were bonded to an aluminum prototype that allowed the simulation of four misalignment situations (n = 10). Three of these situations occurred at the initial phase (in which a 0.0...

  3. Comparative study of friction between metallic and conventional interactive self-ligating brackets in different alignment conditions

    OpenAIRE

    Sérgio Ricardo Jakob; Davison Matheus; Maria Cristina Jimenez-Pellegrin; Cecília Pedroso Turssi; Flávia Lucisano Botelho do Amaral

    2014-01-01

    OBJECTIVE: The aim of this study was to compare the friction between three bracket models: conventional stainless steel (Ovation, Dentsply GAC), self-ligating ceramic (In-Ovation, Denstply GAC) and self-ligating stainless steel brackets (In-Ovation R, Dentsply GAC). METHODS: Five brackets were used for each model. They were bonded to an aluminum prototype that allowed the simulation of four misalignment situations (n = 10). Three of these situations occurred at the initial phase (in which a 0...

  4. Lazy & quarrelsome brackets

    NARCIS (Netherlands)

    Visser, A.

    2008-01-01

    In this paper we study two (kinds of) systems of brackets in an algebraic way. Lazy brackets have the same effect as introducing or eliminating 'a sufficient amount' of ordinary brackets at the same time. Quarrelsome brackets are brackets corresponding to different types of 'levels': think e.g. of t

  5. Clinical Survival of Rebonded Brackets with Different ARI Scores

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Ahangar Atashi

    2016-01-01

    Full Text Available Introduction: Bracket debonding is one of the most common events in orthodontics. The aim of the present study was to quantitatively compare clinical survival of rebonded brackets with different ARI scores with new brackets rebonding. Materials and Methods: The subjects in the present study consisted of 74 patients with 76 debonded brackets on maxillary first and second premolars. After refreshing the bracket base of the debonded brackets, they were assigned in two groups: group A with 27 brackets of ARI≥4 and group B with 28 brackets of ARI≤2. In 21 cases, new brackets were used (group C. The frequency of the debonding in each rebonded group during treatment was calculated in intervals of 6,12,18 mounths after onset of bracket rebonding . Chi-squared test was used to compare the frequency of debonded brackets. Results: The frequency of debonded brackets was significantly higher in group B (ARI≤2 than those of groups A (ARI≥4 and C (new brackets. The number of debonded brackets were not significantly different between groups A (ARI≥4 and C (new brackets. Conclusion: Rebonding strength of debonded brackets in those that the failure is presented between adhesive and enamel (ARI≥4 could be clinically acceptable with no need to use new brackets.    Key words: dental bonding; orthodontic brackets; prevalence

  6. Comparative study of friction between metallic and conventional interactive self-ligating brackets in different alignment conditions

    Directory of Open Access Journals (Sweden)

    Sérgio Ricardo Jakob

    2014-06-01

    Full Text Available OBJECTIVE: The aim of this study was to compare the friction between three bracket models: conventional stainless steel (Ovation, Dentsply GAC, self-ligating ceramic (In-Ovation, Denstply GAC and self-ligating stainless steel brackets (In-Ovation R, Dentsply GAC. METHODS: Five brackets were used for each model. They were bonded to an aluminum prototype that allowed the simulation of four misalignment situations (n = 10. Three of these situations occurred at the initial phase (in which a 0.016-in nickel-titanium wire was used: 1. horizontal; 2. vertical; and 3. simultaneous horizontal/vertical. One of the situations occurred at the final treatment phase: 4. no misalignment (in which a 0.019 x 0.025-inch stainless steel rectangular wire was used. The wires slipped through the brackets and friction was measured by a Universal Testing Machine. RESULTS: Analysis of variance followed by Tukey's Test for multiple comparisons (α = 0.05 were applied to assess the results. Significant interaction (p < 0.01 among groups was found. For the tests that simulated initial alignment, Ovation(r bracket produced the highest friction. The two self-ligating models resulted in lower and similar values, except for the horizontal situation, in which In-Ovation C(r showed lower friction, which was similar to the In-Ovation R(r metallic model. For the no misalignment situation, the same results were observed. CONCLUSION: The self-ligating system was superior to the conventional one due to producing less friction. With regard to the material used for manufacturing the brackets, the In-Ovation C(r ceramic model showed less friction than the metallic ones.

  7. Influence of various surface-conditioning methods on the bond strength of metal brackets to ceramic surfaces

    NARCIS (Netherlands)

    Schmage, P; Nergiz, [No Value; Herrmann, W; Ozcan, M; Nergiz, Ibrahim; �zcan, Mutlu

    2003-01-01

    With the increase in adult orthodontic treatment comes the need to find a reliable method for bonding orthodontic brackets onto metal or ceramic crowns and fixed partial dentures. In this study, shear bond strength and surface roughness tests were used to examine the effect of 4 different surface co

  8. Adhesives for orthodontic bracket bonding

    Directory of Open Access Journals (Sweden)

    Déborah Daniella Diniz Fonseca

    2010-04-01

    Full Text Available The advent of acid etching, introduced by Buonocore in 1955, brought the possibility of bonding between the bracket base and enamel, contributing to more esthetic and conservative orthodontics. This direct bracket bonding technique has brought benefits such as reduced cost and time in performing the treatment, as well as making it easier to perform oral hygiene. The aim of this study was to conduct a survey of published studies on orthodontic bracket bonding to dental enamel. It was verified that resin composites and glass ionomer are the most studied and researched materials for this purpose. Resin-modified glass ionomer, with its biocompatibility, capacity of releasing fluoride and no need for acid etching on the tooth structure, has become increasingly popular among dentists. However, due to the esthetic and mechanical properties of light polymerizable resin composite, it continues to be one of the adhesives of choice in the bracket bonding technique and its use is widely disseminated.

  9. Hydrodynamic Nambu Brackets derived by Geometric Constraints

    CERN Document Server

    Blender, Richard

    2015-01-01

    A geometric approach to derive the Nambu brackets for ideal two-dimensional (2D) hydrodynamics is suggested. The derivation is based on two-forms with vanishing integrals in a periodic domain, and with resulting dynamics constrained by an orthogonality condition. As a result, 2D hydrodynamics with vorticity as dynamic variable emerges as a generic model, with conservation laws which can be interpreted as enstrophy and energy functionals. Generalized forms like surface quasi-geostrophy and fractional Poisson equations for the stream-function are also included as results from the derivation. The formalism is extended to a hydrodynamic system coupled to a second degree of freedom, with the Rayleigh-B\\'{e}nard convection as an example. This system is reformulated in terms of constitutive conservation laws with two additive brackets which represent individual processes: a first representing inviscid 2D hydrodynamics, and a second representing the coupling between hydrodynamics and thermodynamics. The results can b...

  10. Motivational Goal Bracketing

    DEFF Research Database (Denmark)

    Nafziger, Julia; Koch, Alexander

    It is a puzzle why people often evaluate consequences of choices separately (narrow bracketing) rather than jointly (broad bracketing). We study the hypothesis that a present-biased individual, who faces two tasks, may bracket his goals narrowly for motivational reasons. Goals motivate because th...... of the tasks. Narrow goals have a stronger motivational force and thus can be optimal. In particular, if one task outcome becomes known before working on the second task, narrow bracketing is always optimal.......It is a puzzle why people often evaluate consequences of choices separately (narrow bracketing) rather than jointly (broad bracketing). We study the hypothesis that a present-biased individual, who faces two tasks, may bracket his goals narrowly for motivational reasons. Goals motivate because...

  11. High-dynamic-range microscope imaging based on exposure bracketing in full-field optical coherence tomography.

    Science.gov (United States)

    Leong-Hoi, Audrey; Montgomery, Paul C; Serio, Bruno; Twardowski, Patrice; Uhring, Wilfried

    2016-04-01

    By applying the proposed high-dynamic-range (HDR) technique based on exposure bracketing, we demonstrate a meaningful reduction in the spatial noise in image frames acquired with a CCD camera so as to improve the fringe contrast in full-field optical coherence tomography (FF-OCT). This new signal processing method thus allows improved probing within transparent or semitransparent samples. The proposed method is demonstrated on 3 μm thick transparent polymer films of Mylar, which, due to their transparency, produce low contrast fringe patterns in white-light interference microscopy. High-resolution tomographic analysis is performed using the technique. After performing appropriate signal processing, resulting XZ sections are observed. Submicrometer-sized defects can be lost in the noise that is present in the CCD images. With the proposed method, we show that by increasing the signal-to-noise ratio of the images, submicrometer-sized defect structures can thus be detected.

  12. Quantum and Classic Brackets

    OpenAIRE

    Kisil, Vladimir V.

    2000-01-01

    We describe an $p$-mechanical (see funct-an/9405002 and quant-ph/9610016) brackets which generate quantum (commutator) and classic (Poisson) brackets in corresponding representations of the Heisenberg group. We \\emph{do not} use any kind of semiclassic approximation or limiting procedures for $\\hbar \\to 0$. Harmonic oscillator considered within the approach. Keywords: Classic and quantum mechanics, Hamilton and Heisenberg equations, Poisson brackets, commutator, Heisenberg group.

  13. Streptococcus mutans counts in plaque adjacent to orthodontic brackets bonded with resin-modified glass ionomer cement or resin-based composite

    Directory of Open Access Journals (Sweden)

    Solange Machado Mota

    2008-03-01

    Full Text Available This study investigated the number of Streptococcus mutans CFU (colony forming units in the saliva and plaque adjacent to orthodontic brackets bonded with a glass ionomer cement - GIC (Fuji Ortho or a resin-based composite - RC (Concise. Twenty male and female patients, aged 12 to 20 years, participated in the study. Saliva was collected before and after placement of appliances. Plaque was collected from areas adjacent to brackets and saliva was again collected on the 15th, 30th, and 45th day after placement. On the 30th day, 0.4% stannous fluoride gel was applied for 4 minutes. No significant modification in the number of Streptococcus mutans CFU in saliva was observed after placement of the fixed orthodontic appliances. On the 15th day, the percentage of Streptococcus mutans CFU in plaque was statistically lower in sites adjacent to GIC-bonded brackets (mean = 0.365 than in those adjacent to RC-bonded brackets (mean = 0.935. No evidence was found of a contribution of GIC to the reduction of CFU in plaque after the 15th day. Topical application of stannous fluoride gel on the 30th day reduced the number of CFU in saliva, but not in plaque. This study suggests that the antimicrobial activity of GIC occurs only in the initial phase and is not responsible for a long-term anticariogenic property.

  14. Comparison of the frictional resistance between archwire and different bracket system: An in vitro study

    Directory of Open Access Journals (Sweden)

    Ajith R Pillai

    2014-01-01

    Full Text Available Background and Objectives: The purpose of this study is to evaluate the frictional resistance generated by conventional stainless steel, radiance ceramic bracket, self-ligating and composite brackets using a 0.019 × 0.025 stainless steel straight length wires in a 022 slot and to select brackets based on their frictional characteristic. Methodology: In order to conduct this study, four different types of bracket system were selected of the mclaughlin-bennet-trevesi (MBT discipline. They are Group 1 - stainless steel, Group 2 - composite bracket Group 3 - (American Orthodontics radiance ceramic bracket Group 4 - self-ligating bracket (SLB (Empower. In this study, five maxillary brackets of an arch of each type were used. All brackets are 0.022 × 0.028" in preadjusted edgewise appliance which simulates the dental arch. Five brackets were bonded to a stainless steel bar of dimension 150 mm × 25 mm × 3 mm. The bracket-arch wire units were submitted to mechanical test with an Instron universal testing machine 3365. A testing apparatus or holding jig was designed to hold the bracket during the mechanical test. Each sample was pulled at a speed of 6 mm for 1 min. Descriptive statistical information including mean and standard deviation of maximum friction force was calculated for each bracket wire combination. Interpretation and Conclusion: The SLB has the least friction among the four groups. The ceramic bracket showed the highest friction followed by stainless steel bracket, composite bracket, and SLB.

  15. Analysis Method of the Solar Equipment Bracket Based on Approximate Linear Elastic Theory%基于近似线性弹性理论的太阳能设备支架稳性分析方法

    Institute of Scientific and Technical Information of China (English)

    毛潭; 冯志彬; 尹宇鹤; 潘博

    2015-01-01

    This article presents an instability analysis method based on approximate linear elastic theory ,for solving the installing stability issues of solar panels bracket supporting by ground column. Firstly ,we determined the bracket installing angle according to the simulation results of illumination conditions in Beijing area based on shadow ratio method and spherical trigonometry. Secondly,we used static analysis and linear buckling analysis method to anlyze and compare three representative bracket structures by checking their respective force loads ,structural strength and stability. Finally ,we verified the accuracy and reliability of instability analysis method based on approximate linear elastic theory through experiments.%针对地面立柱式太阳能电池板支架安装稳定性问题,引入基于近似线性弹性理论的失稳分析的方法求解。首先基于影子倍率法和球形三角函数法模拟北京光照情况并确定太阳能设备的支架安装角度;其次利用静力学分析法和线性屈曲分析法,通过分析比较三种有代表性的支架系统方案,分别计算出受力载荷、结构强度和稳定性;最后通过实例验证近似线性弹性理论的失稳分析方法的准确性和可靠性。

  16. Assessment of bracket surface morphology and dimensional change

    Directory of Open Access Journals (Sweden)

    Pillai Devu Radhakrishnan

    2017-01-01

    Full Text Available Objective: The objective of this study was to compare the surface morphology and dimensional stability of the bracket slot at the onset of treatment and after 12 months of intraoral exposure. The study also compared the amount of calcium at the bracket base which indicates enamel loss among the three orthodontic brackets following debonding after 12 months of intraoral exposure. Materials and Methods: The sample consisted of 60 (0.022” MBT canine brackets. They were divided into three groups: self-ligating, ceramic bracket with metal slot, and stainless steel (SS brackets. The slot dimensions, micromorphologic characteristics of as-received and retrieved brackets were measured with a stereomicroscope and scanning electron microscope (SEM, respectively. The amount of calcium at the bracket base which indicates enamel damage was quantified using energy-dispersive X-ray spectrometry (EDX. Results: The results showed statistically significant alterations (P < 0.05 in the right vertical dimension, internal tie wing width (cervical, right and left depth of the slot (Kruskal–Wallis test. Multiple comparison using Mann–Whitney test showed that ceramic brackets underwent (P < 0.05 minimal alterations in the right vertical dimension, internal tie wing width (cervical, right and left depth of the slot (0.01 mm, −0.003 mm, 0.006 mm, −0.002 mm, respectively when compared with the changes seen in SS and self-ligating brackets. SEM analysis revealed an increase in the surface roughness of ceramic with metal slot brackets and self-ligating bracket showed the least irregularity. The presence of calcium was noted on all evaluated brackets under EDX, but ceramic with metal slot brackets showed a significantly greater amount of enamel loss (P = 0.001. Conclusion: Ceramic brackets were found to be dimensionally stable when compared to SS and self-ligating. Self-ligating bracket showed minimal surface irregularity. Ceramic with metal slot brackets showed a

  17. Correlates of Narrow Bracketing

    DEFF Research Database (Denmark)

    Koch, Alexander; Nafziger, Julia

    We examine whether different phenomena of narrow bracketing can be traced back to some common characteristic and whether and how different phenomena are related. We find that making dominated lottery choices or ignoring the endowment when making risky choices are related phenomena and are both as...

  18. Simulation and experimental validation of powertrain mounting bracket design obtained from multi-objective topology optimization

    Directory of Open Access Journals (Sweden)

    Qinghai Zhao

    2015-06-01

    Full Text Available A framework of multi-objective topology optimization for vehicle powertrain mounting bracket design with consideration of multiple static and dynamic loading conditions is developed in this article. Incorporating into the simplified isotropic material with penalization model, compromise programming method is employed to describe the multi-objective and multi-stiffness topology optimization under static loading conditions, whereas mean eigenvalue formulation is proposed to analyze vibration optimization. To yield well-behaved optimal topologies, minimum member size and draw constraint are settled for meeting manufacturing feasibility requirements. The ultimate mounting bracket is reconstructed based on the optimum results. Numerical analyses of the bracket are performed, followed by physical tests. It is proven that topology optimization methodology is promising and effective for vehicle component design.

  19. Shear Bond Strength of Orthodontic Brackets Bonded to Zirconium Crowns

    Science.gov (United States)

    Mehmeti, Blerim; Azizi, Bleron; Kelmendi, Jeta; Iljazi-Shahiqi, Donika; Alar, Željko

    2017-01-01

    Background An increasing demand for esthetic restorations has resulted in an increased use of all-ceramic restorations, such as zirconium. However, one of the challenges the orthodontist must be willing to face is how to increase bond strength between the brackets and various ceramic restorations.Bond strength can beaffected bybracket type, by the material that bracketsaremade of, and their base surface design or retention mode. ​ Aim: of this study was to perform a comparative analysis of the shear bond strength (SBS) of metallic and ceramic orthodontic brackets bonded to all-zirconium ceramic surfaces used for prosthetic restorations, and also to evaluate the fracture mode of these two types of orthodontic brackets. Material and methods Twenty samples/semi-crowns of all-zirconium ceramic, on which orthodontic brackets were bonded, 10 metallic and 10 ceramic polycrystalline brackets, were prepared for this research. SBS has been testedby Universal Testing Machine, with a load applied using a knife edged rod moving at a fixed rate of 1 mm/min, until failure occurred. The force required to debond the brackets was recorded in Newton, then SBS was calculated to MPa. In addition, the samples were analyzed using a digital camera magnifier to determine Adhesive Remnant Index (ARI). Statistical data were processed using t-test, and the level of significance was set at α = 0.05. Results Higher shear bond strength values were observed in metallic brackets bonded to zirconium crowns compared tothoseof ceramic brackets, with a significant difference. During the test, two of the ceramic brackets were partially or totally damaged. Conclusion Metallic brackets, compared to ceramic polycrystalline brackets, seemed tocreate stronger adhesion with all-zirconium surfaces due to their better retention mode. Also, ceramic brackets showed higher fragility during debonding. PMID:28827846

  20. Bracketing effects on risk tolerance

    Directory of Open Access Journals (Sweden)

    Ester Moher

    2010-08-01

    Full Text Available Research has shown that risk tolerance increases when multiple decisions and associated outcomes are presented together in a broader ``bracket'' rather than one at a time. The present studies disentangle the influence of problem bracketing (presenting multiple investment options together from that of outcome bracketing (presenting the aggregated outcomes of multiple decisions, factors which have been deliberately confounded in previous research. In the standard version of the bracketing task, in which participants decide how much of an initial endowment to invest into each in a series of repeated, identical gambles, we find a problem bracketing effect but not an outcome bracketing effect. However, this pattern of results does not generalize to the cases of non-identical gambles nor discrete choice, where we fail to find the standard bracketing effect.

  1. Bonding polycarbonate brackets to ceramic: : Effects of substrate treatment on bond strength

    NARCIS (Netherlands)

    Özcan, Mutlu; Vallittu, Pekka K.; Peltomäki, Timo; Huysmans, Marie-Charlotte; Kalk, Warner

    2004-01-01

    This study evaluated the effects of 5 different surface conditioning methods on the bond strength of polycarbonate brackets bonded to ceramic surfaces with resin based cement. Six disc-shaped ceramic specimens (feldspathic porcelain) with glazed surfaces were used for each group. The specimens were

  2. Bonding polycarbonate brackets to ceramic : Effects of substrate treatment on bond strength

    NARCIS (Netherlands)

    Özcan, Mutlu; Vallittu, Pekka K.; Peltomäki, Timo; Huysmans, Marie-Charlotte; Kalk, Warner

    2004-01-01

    This study evaluated the effects of 5 different surface conditioning methods on the bond strength of polycarbonate brackets bonded to ceramic surfaces with resin based cement. Six disc-shaped ceramic specimens (feldspathic porcelain) with glazed surfaces were used for each group. The specimens were

  3. Effect of Adhesive Type on the Shear Bond Strength of Metal Brackets to Two Ceramic Substrates

    Directory of Open Access Journals (Sweden)

    Mohammad Sadegh Ahmad Akhoundi

    2014-04-01

    Full Text Available Increased number of adult patients requesting orthodontic treatment result in bonding bracket to ceramic restorations more than before. The aim of this study was to evaluate and compare the shear bond strength of orthodontic brackets bonded to two types of ceramic bases with conventional orthodontic bonding resin and a new nano-filled composite resin.Twenty four feldespathic porcelain and 24 lithium disilicate ceramic disks were fabricated. All of the samples were conditioned by sandblasting, hydrofluoric acid and silane. Maxillary incisor metal brackets were bonded to half of the disks in each group by conventional orthodontic bonding resin and the other half bonded with a nano-filled composite. The samples then were thermocycled for 2000 cycle between 5-55° C. Shear bond strength was measured and the mode of failure was examined. Randomly selected samples were also evaluated by SEM.The lowest bond strength value was found infeldespathic ceramic bonded by nano-filled composite (p<0.05. There was not any statistically significant difference between other groups regarding bond strength. The mode of failure in the all groups except group 1 was cohesive and porcelain damages were detected.Since less damages to feldspathic porcelain was observed when the nano-filled composite was used to bond brackets, the use of nano-filled composite resins can be suggested for bonding brackets to feldspathic porcelain restorations.

  4. Estudo comparativo da resistência adesiva da interface resina/braquete, sob esforços de cisalhamento, empregando três resinas compostas e três tipos de tratamento na base do braquete Comparative study of the shear bond strength of the resin/bracket interface, using three different resin composites and three different treatments in the base of the bracket

    Directory of Open Access Journals (Sweden)

    Adriano Lia Mondelli

    2007-06-01

    , associado ou não ao jateamento com óxido de alumínio, houve uma queda dos valores de resistência ao cisalhamento. O tratamento com jateamento de óxido de alumínio na base dos braquetes melhorou todos os valores de adesividade para todos os materiais de colagem utilizados nesta pesquisa.AIM: Considering that the adhesion between the brackets and the resin is chemo-mechanical, the aim of this study was to investigate: 1 the efficacy of the method used to assess the bond strength at the resin/bracket interface; 2 the shear bond strength of the resin/bracket interface using three resin composites (Concise orthodontic, Transbond XT and Filtek Z-250; 3 the effect of sandblasting of the base of the metallic bracket with aluminum oxide, associated or not to the application of adhesive. METHODS: Shear bond strength was carried out at a universal testing machine. Data were submitted to analysis of variance and Tukey multiple comparison test. RESULS AND CONCLUSIONS: The occurrence of 12.5% of cohesive failures may be considered minimal, thus indicating that the method is appropriate to assess the bond strength at the resin/bracket interface. The different resin composites (Concise Orthodontic, Transbond XT and Filtek Z-250 used for bonding without any previous surface treatment of the bracket (control groups resulted in similar shear bond strength. The application of adhesive, with or without previous sandblasting of the base of the bracket, improved the shear bond strength for the Concise orthodontic resin composite, when compared to its control group. Sandblasting of the bracket, regardless of the combined use of adhesive, was statistically superior for the Transbond XT resin composite when compared to its control group. The application of the adhesive Single Bond in the base of the bracket, with or without previous sandblasting, promoted a decrease in the shear bond strength for the Filtek Z-250 resin composite. Sandblasting of the metallic bracket with aluminum oxide

  5. Variação da curvatura da base de braquetes "Straight-Wire": estudo comparativo entre quatro marcas comerciais Straight-wire base brackets curvature: analysis of four differents manufactures

    Directory of Open Access Journals (Sweden)

    Luciana de Paula Gontijo

    2004-06-01

    Full Text Available Este trabalho objetivou avaliar as qualidades arquiteturais das bases dos braquetes "Straight-Wire" de quatro marcas comerciais (Morelli, Abzil Lancer, Unitek e A-Company comparando as suas curvaturas médias no sentido oclusogengival e mesiodistal. As curvaturas das bases dos braquetes foram medidas por meio de uma máquina de medidas universais da Société Genevoise D' Instruments de Physique, marca CSIP, modelo MUL-300, e os dados encontrados foram transferidos para um software de desenho AutoCAD 2000, gerando superfícies em ambiente tridimensional, a partir das quais se mediu a curvatura e o raio das bases dos acessórios ortodônticos. Os resultados demonstraram que a curvatura da base de cada braquete variou em sua extensão e que para um mesmo elemento dentário, as curvaturas e seus respectivos raios variaram entre as marcas comerciais analisadas.The objective of this study was to determine the average occlusogingival and mesiodistal curvature of the bases of straight-wire brackets. Brackets from four different manufactures were utilized: Morelli, Abzil Lancer, Unitek and A-Company. The measurements of the curvature of the bases of the brackets were, initially, taken with a universal instrument of the Société Genevoise D'Instruments de Physique, known as CSIP, model MUL-300. The data obtained was transferred to an AUTOCAD 2000 software, which generated a three dimensional image, where the curvature and the radius of the bases were finally measured. The results demonstrated a great variability of these measurements among the four different brands for the same bracket.

  6. Optimal design of an extrusion process for a hinge bracket

    Energy Technology Data Exchange (ETDEWEB)

    Na, Geum Ju; Jang, Myung Geun; Kim, Jong Bong [Seoul National University, Seoul (Korea, Republic of)

    2016-05-15

    This study considers process design in forming a hinge bracket. A thin hinge bracket is typically produced by bending a sheet panel or welding a hollow bar into a sheet panel. However, the hinge bracket made by bending or welding does not have sufficient durability in severe operating conditions because of the stress concentration in the bended region or the low corrosion resistance of the welded region. Therefore, this study uses forming to produce the hinge bracket part of a foldable container and to ensure durability in difficult operating conditions. An extrusion process for a T-shaped hinge bracket is studied using finite element analysis. Preliminary analysis shows that a very high forging load is required to form the bracket by forging. Therefore, extrusion is considered as a candidate process. Producing the part through the extrusion process enables many brackets to be made in a single extrusion and through successive cutting of the extruded part, thereby reducing the manufacturing cost. The design focuses on reducing the extrusion load and on ensuring shape accuracy. An initial billet is designed to reduce the extrusion load and to obtain a geometrically accurate part. The extruded part is bent frequently because of uneven material flow. Thus, extrusion die geometries are designed to obtain straight parts.

  7. Effect of surface treatment of brackets and mechanical cycling on adhesion to enamel.

    Science.gov (United States)

    Arrais, Fabiola Rossato; Degrazia, Felipe; Peres, Bernardo Urbanetto; Ferrazzo, Vilmar Antonio; Grehs, Renesio Armindo; Valandro, Luiz Felipe

    2014-01-01

    This in vitro study sought to evaluate how surface conditioning from bracket and mechanical cycling aging affected the bond strength between metallic brackets and bovine enamel, and to determine the adhesive remnant index. Eighty bovine incisors were embedded in acrylic resin using polyvinyl chloride rings and divided into 4 groups based on surface treatment (n = 20). Group 1 (control) received no surface treatment, Group 2 specimens were sandblasted with aluminum oxide particles, Group 3 specimens were sandblasted with silicon oxide and treated with a tribochemichemical silica coupling agent, and Group 4 specimens were primed with a multidomain protein-based agent. Half of the specimens were submitted to shear bond testing, while the others were subjected to mechanical cycling. ANOVA showed that mechanical cycling did not have a significant influence on bond strength (P = 0.9244), while surface conditioning of the brackets did (P = 0.0001). Tukey's test results were similar for mechanical cycling, and indicated that only Group 3 significantly improved the resin bond to the brackets; however, this group also demonstrated the highest percentage of enamel failure.

  8. Análise da qualidade de adesão de diferentes bases de braquetes metálicos Analysis of the adhesion quality of different metallic bracket bases

    Directory of Open Access Journals (Sweden)

    Danielle Morello Park

    2005-02-01

    Full Text Available Diante das diferenças existentes nas características das bases dos braquetes usados atualmente, objetivou-se neste trabalho comparar entre si três tipos de bases de braquetes metálicos (Monobloc, Equilibrium e Dynalock. Foram utilizados 36 pré-molares humanos, divididos em 3 grupos de 12 dentes. Os dentes foram incluídos em troquéis com gesso pedra tipo IV e posicionados com suas faces vestibulares perpendiculares à base do troquel. Todos os braquetes foram colados com o compósito Concise Ortodôntico e submetidos ao ensaio de cisalhamento em uma Máquina Universal com uma velocidade de 0,5 mm por minuto. O braquete Monobloc obteve o maior valor médio de resistência adesiva (x = 28,19 Kgf/cm², sendo superior estatisticamente aos braquetes Equilibrium (x = 18,07 Kgf/cm² e Dynalock (x = 18,24 Kgf/cm². Em relação ao ARI (Índice de Remanescente Resinoso, não foi encontrada diferença estatística entre os braquetes testados.Considering the differences in the bracket bases currently used, it was performed a study with the purpose of comparing three different metallic bracket bases commercially available. It was used 36 human bicuspids divided into 3 groups of 12 teeth. These teeth were immersed in a troquel with gypsy stone type IV and positioned with their buccal face perpendicular to the troquel base. For each group of teeth it was bonded one of the three brackets using Concise Orthodontic composite. Afterwards they were submitted to a shear bound strength test in a universal machine calibrated for a 0,5mm/minute speed. Monobloc bracket base showed the greater mean value of adhesive resistance (x = 28,19 Kgf/cm², result statistically superior to that shown by Equilibrium (x = 18,07 Kgf/cm² and Dynalock (x = 18,24 Kgf/cm² ones. The ARI (Adhesive reminiscent index showed no statistically difference among the bracket bases studied.

  9. In -Vitro: Evaluation of Corrosion Behavior of Orthodontic Stainless Steel Brackets to Salad Dressing

    Directory of Open Access Journals (Sweden)

    S.F.Hussain

    2016-11-01

    Full Text Available The objectives of this study were to investigate the corrosion behavior of conventional and self-ligating stainless steel brackets and the surface structural changes in response to salad dressing. Damon, In-Ovation,Smart clip, Discovery, OMNI and Masel brackets were all included in the study. For the control group, the brackets were placed in Petri dishes with Potassium Ferrocyanide (Fe [CN]6K4 and distilled water. Whereasas for the experimental group, the brackets were incorporated into the same reagent mixed with Oil-based - Kraft Classic French Oil and Water-based-Salad Magic, Herb and Garlic Dressing. The released ferrous ion concentrations were measured by spectrophotometer after 24 and 48 hours. Scanning electron microscope was used to analyze surface changes of the brackets. All types of brackets demonstrated signs of corrosion. Generally, self-ligating brackets were more susceptible to corrosion than the conventional ones the most extensive corrosion was seen in In-Ovation R™. Meanwhile, Masel was the most corroded brackets for conventional brackets.The oil-based salad dressing illustrated the most extensive corrosion in all brackets. Self-ligating brackets, Inovation R™ showed pitting corrosion on the wings. Smart clip showed surfaces corrosion only. The commonly ingested fluids aggravate the corrosive process, and this is related to sodium chloride content.

  10. Friction between different wire bracket combinations in artificial saliva: an in vitro evaluation

    Directory of Open Access Journals (Sweden)

    Tatiana Kelly da Silva Fidalgo

    2011-02-01

    Full Text Available OBJECTIVE: The objective this work was to assess the friction coefficient between brackets and wires of different materials under conditions simulating the oral environment. MATERIAL AND METHODS: Stainless steel (SS and titanium-molybdenum alloy (TMA wires of 0.019x0.025-in diameter (American Orthodontics and polycarbonate bracket (American Orthodontics, ceramic bracket (American Orthodontics, and metal bracket (3M Unitek with slots of 0.022x0.030-in were used. The friction coefficient was assessed by means of mechanical traction with the system immersed in artificial saliva. The mean roughness of both wire surface and bracket slots was evaluated by using a surface profilometer. RESULTS: The system using TMA wire and polycarbonate bracket had the highest roughness (p<0.05. SS wire with ceramic bracket had the highest friction coefficient, whereas the use of metallic bracket yielded the lowest (p<0.05. However, it was observed a statistically significant difference in the system using TMA wire and ceramic bracket compared to that using TMA wire and polycarbonate bracket (p=0.038. CONCLUSIONS: Ceramic brackets in association with SS wire should be judiciously used, since this system showed a high friction coefficient.

  11. Design manual for HANARO in-chimney bracket

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Soo; Cho, Y. G.; Whang, S. Y.; Wu, J. S.; Jun, B. J

    2000-06-01

    As a supplementary structure supporting the irradiation facilities, the in-chimney bracket holds guide tubes whose holding position in CT or IR is the middle part of the instrumented facility between the hole spider and the robot arm already provided in the reactor pool liner. Also, the bracket grips the upper part of the guide tubes when it is applied to hold the instrumented facility loaded in OR sites. The irradiation test will be successfully conducted since this bracket reduces the flow-induced vibration (FIV) and the dynamic response to seismic load. The installation position of the bracket is 60 cm below the top of the chimney, i.e., thermo siphoning hole position. To evaluate the structural integrity on the in-chimney bracket and the related reactor structures, ANSYS finite element analysis model is developed and the dynamic characteristics are analyzed. The seismic response analyses were performed for the in-chimney bracket and the related reactor structures of HANARO under the design earthquake response spectrum loads of OBE and SSE. The analysis results show that the stress values in main points of reactor structures and in-chimney bracket for the seismic loads are also within the ASME code limits. It is also confirmed that the fatigue usage factor is much less than 1.0. Therefore any damage on structural integrity is not expected when the in-chimney bracket is installed at the upper part of the reactor chimney. This bracket had been designed and manufactured based on the dimensions of the as-built chimney. In the process of design and preliminary installation, chimney measurement tools, dummy chimney, and installation tools were developed and the installation procedure was prepared and verified through the installation rehearsal.

  12. Microstructural and mechanical characterization of contemporary lingual orthodontic brackets.

    Science.gov (United States)

    Zinelis, Spiros; Sifakakis, Iosif; Katsaros, Christos; Eliades, Theodore

    2014-08-01

    To investigate the composition and the microstructural and mechanical characterization of three different types of lingual brackets. Incognito™ (3M Unitek), In-Ovation L (DENTSPLY GAC) and STb™ (Light Lingual System, ORMCO) lingual brackets were studied under the scanning electron microscope employing backscattered electron imaging and their elemental composition was analysed by energy-dispersive X-ray microanalysis. Additionally, Vickers hardness was assessed using a universal hardness-testing machine, and the indentation modulus was measured according to instrumented indentation test. Two-way analysis of variance was conducted employing bracket type and location (base and wing) as discriminating variable. Significant differences among groups were allocated by post hoc Student-Newman-Keuls multiple comparison analysis at 95% level of significance. Three different phases were identified for Incognito and In-Ovation L bracket based on mean atomic number contrast. On the contrary, STb did not show mean atomic contrast areas and thus it is recognized as a single phase. Incognito is a one-piece bracket with the same structure in wing and base regions. Incognito consists mainly of noble metals while In-Ovation L and STb show similar formulations of ferrous alloys in wing and base regions. No significant differences were found between ferrous brackets in hardness and modulus values, but there were significant differences between wing and base regions. Incognito illustrated intermediate values with significant differences from base and wing values of ferrous brackets. Significant differences exist in microstructure, elemental composition, and mechanical properties among the brackets tested; these might have a series of clinical implications during mechanotherapy. © The Author 2013. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  13. Transparent magnesium aluminate spinel: a prospective biomaterial for esthetic orthodontic brackets.

    Science.gov (United States)

    Krishnan, Manu; Tiwari, Brijesh; Seema, Saraswathy; Kalra, Namitha; Biswas, Papiya; Rajeswari, Kotikalapudi; Suresh, Madireddy Buchi; Johnson, Roy; Gokhale, Nitin M; Iyer, Satish R; Londhe, Sanjay; Arora, Vimal; Tripathi, Rajendra P

    2014-11-01

    Adult orthodontics is recently gaining popularity due to its importance in esthetics, oral and general health. However, none of the currently available alumina or zirconia based ceramic orthodontic brackets meet the esthetic demands of adult patients. Inherent hexagonal lattice structure and associated birefringence limits the visible light transmission in polycrystalline alumina and make them appear white and non transparent. Hence focus of the present study was to assess the feasibility of using magnesium aluminate (MgAl2O4) spinel; a member of the transparent ceramic family for esthetic orthodontic brackets. Transparent spinel specimens were developed from commercially available white spinel powder through colloidal shaping followed by pressureless sintering and hot isostatic pressing at optimum conditions of temperature and pressure. Samples were characterized for chemical composition, phases, density, hardness, flexural strength, fracture toughness and optical transmission. Biocompatibility was evaluated with in-vitro cell line experiments for cytotoxicity, apoptosis and genotoxicity. Results showed that transparent spinel samples had requisite physico-chemical, mechanical, optical and excellent biocompatibility for fabricating orthodontic brackets. Transparent spinel developed through this method demonstrated its possibility as a prospective biomaterial for developing esthetic orthodontic brackets.

  14. Effects of third-order torque on frictional force of self-ligating brackets.

    Science.gov (United States)

    Muguruma, Takeshi; Iijima, Masahiro; Brantley, William A; Ahluwalia, Karamdeep S; Kohda, Naohisa; Mizoguchi, Itaru

    2014-11-01

    To investigate the effects of third-order torque on frictional properties of self-ligating brackets (SLBs). Three SLBs (two passive and one active) and three archwires (0.016 × 0.022-inch nickel-titanium, and 0.017 × 0.025-inch and 0.019 × 0.025-inch stainless steel) were used. Static friction was measured by drawing archwires though bracket slots with four torque levels (0°, 10°, 20°, 30°), using a mechanical testing machine (n  =  10). A conventional stainless-steel bracket was used for comparison. RESULTS were subjected to Kruskal-Wallis and Mann-Whitney U-tests. Contact between the bracket and wire was studied using a scanning electron microscope. In most bracket-wire combinations, increasing the torque produced a significant increase in static friction. Most SLB-wire combinations at all torques produced less friction than that from the conventional bracket. Active-type SLB-wire combinations showed higher friction than that from passive-type SLB-wire combinations in most conditions. When increasing the torque, more contact between the wall of a bracket slot and the edge of a wire was observed for all bracket types. Increasing torque when using SLBs causes an increase in friction, since contact between the bracket slot wall and the wire edge becomes greater; the design of brackets influences static friction.

  15. Assessment of enamel damage after removal of ceramic brackets.

    Science.gov (United States)

    Kitahara-Céia, Flávia Mitiko Fernandes; Mucha, José Nelson; Marques dos Santos, Paulo Acioly

    2008-10-01

    Since the introduction of ceramic brackets, research has been performed to evaluate enamel damage caused during their removal. One problem in comparing treated and control groups is the absence of assurance that the surfaces were undamaged before the brackets were bonded and debonded, or that superficial treatment applied to the enamel could hinder damage detection. The aim of this in-vitro study was to evaluate enamel injuries during debonding of 3 types of ceramic brackets. Forty-five premolars, extracted for orthodontic purposes, were divided into 3 groups of 15. The enamel surfaces were photographed with a magnifying loupe (60 times) in an optical stereomicroscope (Stemi 2000-C, Zeiss, Oberkochen, Germany) with a digital camera. A different type of backet was bonded and debonded in each group: mechanical retention, mechanical retention with a polymer base, and chemical retention. After debonding, the surfaces were again photographed. The photographs were evaluated for quality of enamel surface according to a predetermined scale. The results were tested by method error and the chi-square test. The damage evaluation comparing the same surface before bonding and after debonding showed no significant statistical difference between the mechanical retention group and the polymer base retention group. There was a significant statistical difference (P ceramic bracket group. The difference between the enamel surfaces before bonding and after debonding brackets with chemical retention was statistically significant; bonding and debonding these brackets resulted in enamel damage.

  16. Influence of Preadjusted Bracket Shape and Positioning Reference on Angulation of Upper Central Incisor.

    Science.gov (United States)

    Topolski, Francielle; de O Accorsi, Mauricio A; Trevisi, Hugo J; Cuoghi, Osmar A; Moresca, Ricardo

    2016-10-01

    To verify the influence of different bracket shapes and placement references according to Andrews and MBT systems on the expression of angulation in upper central incisors (UCI). Bracket positioning and mesiodistal dental movement simulations were performed and the angulations produced in the dental crown were evaluated, based on computed tomography scan images of 30 UCI and AutoCAD software analysis. Rectangular (Andrews) and rhomboid (MBT) brackets were placed according to the references recommended by Andrews and MBT systems - long axis of the clinical crown (LACC) and incisal edge (IE) respectively. Data showed that the use of LACC as reference for bracket positioning produced 5° and 4° UCI angulations in Andrews and MBT brackets respectively. The use of IE produced a 1.2° mean angulation in UCI for both brackets. When the LACC was used as reference for bracket positioning, the UCI crown angulation corresponded to the angulation built into the brackets, regardless of shape, while the use of IE resulted in natural crown angulation, regardless of bracket shape. This research contributes to guide the orthodontist in relation to the different treatment techniques based on the use of preadjusted brackets.

  17. Motivational Goal Bracketing: An Experiment

    DEFF Research Database (Denmark)

    Koch, Alexander; Nafziger, Julia

    We study in an online, real-effort experiment how the bracketing of non-binding goals affects performance in a work-leisure self-control problem. We externally induce the goal bracket - daily goals or a weekly goal - and within that bracket let subjects set goals for how much they want to work over...... a one-week period. Our theoretical model predicts (i) that weekly goals create incentives to compensate for a lower than desired performance today with the promise to work harder tomorrow, whereas daily goals exclude such excuses; (ii) that subjects with daily goals set higher goals in aggregate...... and work harder than those with weekly goals. Our data support these predictions. Surprisingly, however, when goals are combined with an externally enforced commitment that requires subjects to spend less than a minute each day on the task to get started working, performance deteriorates because of high...

  18. Design of the Spining Bracket with Electromagnetic Riveter based on Ergonomic Analysis%基于人机工程分析的手持式电磁铆枪旋转托架设计

    Institute of Scientific and Technical Information of China (English)

    张喆; 曹增强; 陈琦

    2013-01-01

    It analyzed the existing problem of the traditional gantry bracket with electromagnetic riveter which only can be used for plate-shaped product. For the purpose of solving the existing problem, a new spining bracket was introduced based on the gantry bracket. Structure design and the analysis of the kinetic characteristic was completed. The 3D modeling of the mechanical parts and the virtual assembly simulation was finished based on CATIA. Through the ergonomic analysis of DELMIA, it analyzed the operation space and verified the design parameters as well as the simulation of collision interference was done. The results indicate that the spining bracket can meet the design requirements and solve the riveting problem of the arc-shaped product%分析了传统悬挂铆枪的托架只适用于平板状结构产品铆接等问题.为解决此问题,在龙门式托架的基础上提出了新型旋转托架,进行了结构设计并分析了其运动特点,建立了基于CATIA的三维零件模型,进行了虚拟装配,并基于DELMIA分析了托架人机工程的近身作业空间,进行旋转托架的碰撞干涉检查,验证了其初始的设计参数.结果表明旋转托架满足了设计要求,并且可以实现圆弧形结构产品的铆接,基于人机工程的设计方法编短了开发周期,降低了设计成本.

  19. Derived bracket construction up to homotopy

    CERN Document Server

    Uchino, K

    2012-01-01

    We will introduce the notion of higher derived bracket construction in the category of operads and prove that the higher derived bracket construction of Lie operad is equivalent with the cobar construction of Leibniz operad.

  20. Structural support bracket for gas flow path

    Energy Technology Data Exchange (ETDEWEB)

    None

    2016-08-02

    A structural support system is provided in a can annular gas turbine engine having an arrangement including a plurality of integrated exit pieces (IEPs) forming an annular chamber for delivering gases from a plurality of combustors to a first row of turbine blades. A bracket structure is connected between an IEP and an inner support structure on the engine. The bracket structure includes an axial bracket member attached to an IEP and extending axially in a forward direction. A transverse bracket member has an end attached to the inner support structure and extends circumferentially to a connection with a forward end of the axial bracket member. The transverse bracket member provides a fixed radial position for the forward end of the axial bracket member and is flexible in the axial direction to permit axial movement of the axial bracket member.

  1. Reliability analysis of a Shift Platform Bracket Based on ANSYS%基于ANSYS的移动平台支架可靠性分析

    Institute of Scientific and Technical Information of China (English)

    朱亚超; 程欣; 丁善婷; 何涛

    2012-01-01

    The ANSYS finite-element analysis software was adopted to analyze the displacement and deformation of solar energy testing shift platform bracket under weight of automatic tracker and solar panel during testing process.Form variable data was then compared with actual data.The results indicate that: adding one set of lock device and back-up unit at the end of shift platform bracket and reinforcing connection between platform bracket and back-up leg can improve safety and reliability of the whole platform bracket and testing device.%采用ANSYS有限元分析软件,对太阳能测试移动平台支架在测试过程中承受自动追踪器和太阳能集热板重量后发生的位移形变进行分析,比较计算形变量数据与实际数据,得出在移动平台支架尾部增加一组锁死装置和支撑装置,以加强移动平台与支撑腿连结,可提高整个平台支架和测试设备的安全性与可靠性的结论.

  2. Effect of delayed polymerization time and bracket manipulation on orthodontic bracket bonding

    Science.gov (United States)

    Ponikvar, Michael J.

    This study examined the effect of bracket manipulation in combination with delayed polymerization times on orthodontic bracket shear bond strength and degree of resin composite conversion. Orthodontics brackets were bonded to extracted third molars in a simulated oral environment after a set period of delayed polymerization time and bracket manipulation. After curing the bracket adhesive, each bracket underwent shear bond strength testing followed by micro-Raman spectroscopy analysis to measure the degree of conversion of the resin composite. Results demonstrated the shear bond strength and the degree of conversion of ceramic brackets did not vary over time. However, with stainless steel brackets there was a significant effect (p ≤ 0.05) of delay time on shear bond strength between the 0.5 min and 10 min bracket groups. In addition, stainless steel brackets showed significant differences related to degree of conversion over time between the 0.5 min and 5 min groups, in addition to the 0.5 min and 10 min groups. This investigation suggests that delaying bracket adhesive polymerization up to a period of 10 min then adjusting the orthodontic bracket may increase both shear bond strength and degree of conversion of stainless steel brackets while having no effect on ceramic brackets.

  3. Effect of Dental Chair Light on Enamel Bonding of Orthodontic Brackets Using Light Cure Based Adhesive System: An In-Vitro Study

    Science.gov (United States)

    Tiwari, Anil; Shyagali, Tarulatha; Kohli, Sarvraj; Joshi, Rishi; Gupta, Abhishek; Tiwari, Rana

    2016-01-01

    Aim: The aim of this in vitro study was to evaluate the influence of the Dental chair light on the bond strength of light cured composite resin. Materials and Methods: Sixty therapeutically extracted human premolar teeth were randomly allocated to two groups of 30 specimens each. In both groups light cured composite resin (Transbond XT) and MBT premolar metal brackets (3M Unitek) was used to bond brackets. In group I and II light curing was done using Light-emitting diode light curing units without and with the dental chair light respectively. After bonding, all samples were stored in distilled water at room temperature for 24 hours and subsequently tested for shear bond strength and Adhesive Remnant Index (ARI) scores. Data was subjected to Mann Whitney U statistical test. Results: Results indicated that there was significantly higher shear bond strength (7.71 ± 1.90) for the Group II (composite cured with LED and dental chair light) compared with Group I (composite cured with LED LCU only) (5.74 ± 1.13).the obtained difference was statistically significant. There was no statistical significant difference between ARI scores in between the groups. Conclusions: light cure bonding with dental chair light switched on will produce greater bond strength than the conventional bonding. However, the ARI score were similar to both the groups. It is advised that the inexperienced orthodontist should always switch off the dental chair light while bonding for enough working time during the bracket placement. PMID:28077886

  4. Condition based spare parts supply

    NARCIS (Netherlands)

    Lin, X.; Basten, Robertus Johannes Ida; Kranenburg, A.A.; van Houtum, Geert-Jan

    2012-01-01

    We consider a spare parts stock point that serves an installed base of machines. Each machine contains the same critical component, whose degradation behavior is described by a Markov process. We consider condition based spare parts supply, and show that an optimal, condition based inventory policy

  5. A hierarchy of Poisson brackets

    CERN Document Server

    Pavelka, Michal; Esen, Ogul; Grmela, Miroslav

    2015-01-01

    The vector field generating reversible time evolution of macroscopic systems involves two ingredients: gradient of a potential (a covector) and a degenerate Poisson structure transforming the covector into a vector. The Poisson structure is conveniently expressed in Poisson brackets, its degeneracy in their Casimirs (i.e. potentials whose gradients produce no vector field). In this paper we investigate in detail hierarchies of Poisson brackets, together with their Casimirs, that arise in passages from more to less detailed (i.e. more macroscopic) descriptions. In particular, we investigate the passage from mechanics of particles (in its Liouville representation) to the reversible kinetic theory and the passage from the reversible kinetic theory to the reversible fluid mechanics. From the physical point of view, the investigation includes binary mixtures and two-point formulations suitable for describing turbulent flows. From the mathematical point of view, we reveal the Lie algebra structure involved in the p...

  6. Commutativity of missing label operators in terms of Berezin brackets

    Energy Technology Data Exchange (ETDEWEB)

    Boya, Luis J [Dpto. Fisica Teorica, Facultad de Ciencias, Universidad de Zaragoza, E-50009 Zaragoza (Spain); Campoamor-Stursberg, Rutwig [Dpto. GeometrIa y TopologIa, Fac. CC. Matematicas, Universidad Complutense de Madrid, Plaza de Ciencias, 3 E-28040 Madrid (Spain)], E-mail: luisjo@unizar.es, E-mail: rutwig@mat.ucm.es

    2009-06-12

    We obtain a criterion on the commutativity of polynomials in the enveloping algebra of a Lie algebra in terms of an involution condition with respect to the Berezin bracket. As an application, it is shown that the commutativity requirement of missing label operators for reduction chains in the missing label problem can be solved analytically.

  7. Comparison of periodontal condition between conventional and self-ligating brackets%自锁托槽与传统托槽矫治器对牙周健康影响的比较研究

    Institute of Scientific and Technical Information of China (English)

    张丽雯; 徐宝华; 周于翔; 武冠英

    2010-01-01

    目的 对比戴用自锁托槽与传统托槽矫治器后牙周指数的变化.材料和方法选取12~18岁正畸患者80例,按矫治器类型分为两组:实验组,40例采用AO公司生产的T3自锁托槽矫正的患者;对照组,采用杭州西湖公司生产的徐氏托槽矫正的患者40例.由同一牙周专科医师分别检测80例患者治疗前和治疗6个月的各项牙周指数(GI,PLI,SBI,PD).结果 治疗6个月后两组间牙周指数(GI,PLI,SBI,PD)差异无显著性.结论 自锁托槽矫治器不会更有利于牙周组织的健康,牙周的健康状况取决于患者的口腔卫生状况.%Objective To compare the periodontal indices between the use of self-ligating brackets and conventional pre-adjusted brackets. Methods Eighty patients (12 to 18 years old) were divided into 2 groups (group A: 40 patients with self-ligating brackets and group B: 40 patients with conventional pre-adjusted brackets). Periodontal indices (GI, PLI, SBI and PD) were examined in both groups. Results No difference was found in the indices recorded between the two groups after 6months of treatment. Conclusions Self-ligating brackets did not have an advantage over conventional brackets with respect to the periodontal status.

  8. Morphological changes in the enamel that affects the bonding of brackets: a review

    OpenAIRE

    Pereira,Lúcia Coelho Garcia; Orosco,Fernando Accorsi; Coura, Paulo Eduardo; Oliveira, Silvio Santana de; Coura, Luiz Carlos

    2016-01-01

    A literature review on the existing information about bonding of orthodontic brackets on altered enamel surfaces, the influence of such surfaces on adhesion, and the most favorable conditions for achieving better bond strength is presented. Studies on bracket adhesion have identified the conditions that lead to morphological changes in enamel as dental fluorosis and dental bleaching. In this review, each of these conditions that alter the enamel surface and pose a major challenge to clinical ...

  9. Delayed bracket placement in orthodontic treatment

    Directory of Open Access Journals (Sweden)

    Chandra Wigati

    2008-12-01

    Full Text Available Background: Beside bracket position, the timing of bracket placement is one of the most essential in orthodontic treatment with fixed appliances. Even it seems simple the timing of bracket placement can be crucial and significantly influence the result of orthodontic treatment. However it is often found brackets are placed without complete understanding of its purpose and effects, which could be useless and even detrimental for the case. Purpose: The aim of this case report is to show that the timing of bracket placement could be different depending on the cases. Case: Five different cases are presented here with different timing of bracket placement. Case management: On these cases, brackets were placed on the upper arch first, on the lower arch first, or even only on some teeth first. Good and efficient orthodontic treatment results were achieved. Conclusion: For every orthodontic case, from the very beginning of treatment, bracket should be placed with the end result in mind. If brackets are correctly placed at a correct time, better treatment result could be achieved without unnecessary round tripping tooth movement.

  10. Nambu bracket and M-theory

    CERN Document Server

    Ho, Pei-Ming

    2016-01-01

    Nambu proposed an extension of dynamical system through the introduction of a new bracket (Nambu bracket) in 1973. This article is a short review of the developments after his paper. Some emphasis are put on a viewpoint that the Nambu bracket naturally describes extended objects which appear in M-theory and the fluid dynamics. The latter part of the paper is devoted to a review of the studies on the Nambu bracket (Lie 3-algebra) in Bagger-Lambert-Gustavsson theory of multiple M2-branes. This paper is a contribution to the proceedings of Nambu memorial symposium (Osaka City University, September 29, 2015).

  11. Electron microscopy analysis of different orthodontic brackets and their adhesion to the tooth enamel.

    Science.gov (United States)

    Ciocan, Delia Ioana; Stanciu, Dragoş; Popescu, Manuela Anca; Miculescu, Florin; Plotog, Ioan; Vărzaru, Gaudenţiu; Ciocan, Lucian Toma

    2014-01-01

    This study proposed to evaluate the surface morphology of different types of orthodontic brackets and the characteristics of their adhesion to the tooth enamel. There have been taken into study six metallic, five ceramic and one polymeric bracket from different brands (Ormco, Lancer, Leone, Damon, 3M, Ultradent, American Orthodontics, Rocky Mountain). The surface base of the each bracket it have been ESEM analyzed using scanning electron microscope Phillips XL-30 ESEM. There have been investigated several parameters that have a potential influence of the bracket-bonding agent interface joint: chemical composition, roughness, surface morphology and wideness. After ESEM analysis, the same metallic and ceramic brackets have been afterwards collated on extracted teeth and subjected to mechanical tests. After the mechanical testing, the samples were once again ESEM investigated. All fractures occurred in the area of the adhesive system, recording adhesive fractures of the tooth-composite resin and composite-bracket, cohesive fractures and both. The metallic brackets surfaces that are optima for a good adhesion is that of a mesh sand blasted and acid etched. From the esthetic brackets, the ceramic ones are superior to polymeric ones regarding bonding to teeth.

  12. Torque expression in self-ligating orthodontic brackets and conventionally ligated brackets: A systematic review

    Science.gov (United States)

    Al-Thomali, Yousef; Mohamed, Roshan-Noor; Basha, Sakeenabi

    2017-01-01

    Background To evaluate the torque expression of self ligating (SL) orthodontic brackets and conventionally ligated brackets and the torque expression in active and passive SL brackets. Material and Methods Our systematic search included MEDLINE, EMBASE, CINAHL, PsychINFO, Scopus, and key journals and review articles; the date of the last search was April 4th 2016. We graded the methodological quality of the studies by means of the Quality Assessment Tool for Quantitative Studies, developed for the Effective Public Health Practice Project (EPHPP). Results In total, 87 studies were identified for screening, and 9 studies were eligible. The quality assessment rated one of the study as being of strong quality, 7 (77.78%) of these studies as being of moderate quality. Three out of 7 studies which compared SL and conventionally ligated brackets showed, conventionally ligated brackets with highest torque expression compared to SL brackets. Badawi showed active SL brackets with highest torque expression compared to passive SL brackets. Major and Brauchli showed no significant differences in torque expression of active and passive SL brackets. Conclusions Conventionally ligated brackets presented with highest torque expression compared to SL brackets. Minor difference was recorded in a torque expression of active and passive SL brackets. Key words:Systematic review, self ligation, torque expression, conventional ligation. PMID:28149476

  13. Heat treatment following surface silanization in rebonded tribochemical silica-coated ceramic brackets: shear bond strength analysis

    Science.gov (United States)

    SILVA, Emilia Adriane; TRINDADE, Flávia Zardo; RESKALLA, Hélcio Nagib José Feres; de QUEIROZ, José Renato Cavalcanti

    2013-01-01

    Objective This study aimed to evaluate the effects of heat treatment on the tribochemical silica coating and silane surface conditioning and the bond strength of rebonded alumina monocrystalline brackets. Material and Methods Sixty alumina monocrystalline brackets were randomly divided according to adhesive base surface treatments (n=20): Gc, no treatment (control); Gt, tribochemical silica coating + silane application; Gh, as per Gt + post-heat treatment (air flux at 100ºC for 60 s). Brackets were bonded to the enamel premolars surface with a light-polymerized resin and stored in distilled water at 37ºC for 100 days. Additionally, half the specimens of each group were thermocycled (6,000 cycles between 5-55ºC) (TC). The specimens were submitted to the shear bond strength (SBS) test using a universal testing machine (1 mm/min). Failure mode was assessed using optical and scanning electron microscopy (SEM), together with the surface roughness (Ra) of the resin cement in the bracket using interference microscopy (IM). 2-way ANOVA and the Tukey test were used to compare the data (p>0.05). Results The strategies used to treat the bracket surface had an effect on the SBS results (p=0.0), but thermocycling did not (p=0.6974). Considering the SBS results (MPa), Gh-TC and Gc showed the highest values (27.59±6.4 and 27.18±2.9) and Gt-TC showed the lowest (8.45±6.7). For the Ra parameter, ANOVA revealed that the aging method had an effect (p=0.0157) but the surface treatments did not (p=0.458). For the thermocycled and non-thermocycled groups, Ra (µm) was 0.69±0.16 and 1.12±0.52, respectively. The most frequent failure mode exhibited was mixed failure involving the enamel-resin-bracket interfaces. Conclusion Regardless of the aging method, Gh promoted similar SBS results to Gc, suggesting that rebonded ceramic brackets are a more effective strategy. PMID:24037072

  14. Heat treatment following surface silanization in rebonded tribochemical silica-coated ceramic brackets: shear bond strength analysis

    Directory of Open Access Journals (Sweden)

    Emilia Adriane Silva

    2013-07-01

    Full Text Available OBJECTIVE: This study aimed to evaluate the effects of heat treatment on the tribochemical silica coating and silane surface conditioning and the bond strength of rebonded alumina monocrystalline brackets. MATERIAL AND METHODS: Sixty alumina monocrystalline brackets were randomly divided according to adhesive base surface treatments (n=20: Gc, no treatment (control; Gt, tribochemical silica coating + silane application; Gh, as per Gt + post-heat treatment (air flux at 100ºC for 60 s. Brackets were bonded to the enamel premolars surface with a light-polymerized resin and stored in distilled water at 37ºC for 100 days. Additionally, half the specimens of each group were thermocycled (6,000 cycles between 5-55ºC (TC. The specimens were submitted to the shear bond strength (SBS test using a universal testing machine (1 mm/min. Failure mode was assessed using optical and scanning electron microscopy (SEM, together with the surface roughness (Ra of the resin cement in the bracket using interference microscopy (IM. 2-way ANOVA and the Tukey test were used to compare the data (p>0.05. RESULTS: The strategies used to treat the bracket surface had an effect on the SBS results (p=0.0, but thermocycling did not (p=0.6974. Considering the SBS results (MPa, Gh-TC and Gc showed the highest values (27.59±6.4 and 27.18±2.9 and Gt-TC showed the lowest (8.45±6.7. For the Ra parameter, ANOVA revealed that the aging method had an effect (p=0.0157 but the surface treatments did not (p=0.458. For the thermocycled and non-thermocycled groups, Ra (µm was 0.69±0.16 and 1.12±0.52, respectively. The most frequent failure mode exhibited was mixed failure involving the enamel-resin-bracket interfaces. CONCLUSION: Regardless of the aging method, Gh promoted similar SBS results to Gc, suggesting that rebonded ceramic brackets are a more effective strategy.

  15. Multiple q-Zeta Brackets

    Directory of Open Access Journals (Sweden)

    Wadim Zudilin

    2015-03-01

    Full Text Available The multiple zeta values (MZVs possess a rich algebraic structure of algebraic relations, which is conjecturally determined by two different (shuffle and stuffle products of a certain algebra of noncommutative words. In a recent work, Bachmann constructed a q-analogue of the MZVs—the so-called bi-brackets—for which the two products are dual to each other, in a very natural way. We overview Bachmann’s construction and discuss the radial asymptotics of the bi-brackets, its links to the MZVs, and related linear (independence questions of the q-analogue.

  16. A comparative study of frictional force in self-ligating brackets according to the bracket-archwire angulation, bracket material, and wire type.

    Science.gov (United States)

    Lee, Souk Min; Hwang, Chung-Ju

    2015-01-01

    This study aimed to compare the frictional force (FR) in self-ligating brackets among different bracket-archwire angles, bracket materials, and archwire types. Passive and active metal self-ligating brackets and active ceramic self-ligating brackets were included as experimental groups, while conventional twin metal brackets served as a control group. All brackets were maxillary premolar brackets with 0.022 inch [in] slots and a -7° torque. The orthodontic wires used included 0.018 round and 0.019 × 0.025 in rectangular stainless steel wires. The FR was measured at 0°, 5°, and 10° angulations as the wire was drawn through the bracket slots after attaching brackets from each group to the universal testing machine. Static and kinetic FRs were also measured. The passive self-ligating brackets generated a lower FR than all the other brackets. Static and kinetic FRs generally increased with an increase in the bracket-archwire angulation, and the rectangular wire caused significantly higher static and kinetic FRs than the round wire (p self-ligating brackets exhibited the lowest static FR at the 0° angulation and a lower increase in static and kinetic FRs with an increase in bracket-archwire angulation than the other brackets, while the conventional twin brackets showed a greater increase than all three experimental brackets. The passive self-ligating brackets showed the lowest FR in this study. Self-ligating brackets can generate varying FRs in vitro according to the wire size, surface characteristics, and bracket-archwire angulation.

  17. In vitro evaluation of frictional forces of two ceramic orthodontic brackets versus a stainless steel bracket in combination with two types of archwires

    Science.gov (United States)

    Arash, Valiollah; Rabiee, Mahmoud; Rakhshan, Vahid; Khorasani, Sara; Sobouti, Farhad

    2015-01-01

    Purpose: The aim of this study was to compare frictional forces between monocrystalline alumina (MA), polycrystalline alumina (PA), and stainless steel (SS) brackets with two SS wires: Rectangular and round. Materials and Methods: In this in vitro study, 60 0.022 brackets [20 PA (0° torque, Forestadent, Germany) and 20 MA (0° torque, Ormco, California, USA)] brackets plus 20 SS brackets (0° torque, Foretadent, Germany) and 60 SS archwires (30 rectangular 0.019 ×0.025 archwires and 30 round 0.018 archwires, Ortho Technology, USA) were used in subgroups of 10 from the combination of all brackets and all archwires. A universal testing machine (Instron, Model STM 250, Germany) was used to investigate the static frictional resistance. The angulation between the bracket and wire was 0°, and the wires were pulled through the slots at a crosshead speed of 10 mm/min. Two-way and one-way analyses of variance (ANOVA) and Tukey tests were used to analyze the data. Results: Mean (SD) static frictional force for each group was as follows: MA + round: 3.47 (0.38); MA + rectangular: 4.05 (0.47); PA + round: 4.14 (0.37); PA + rectangular: 4.45 (0.65); SS + round: 3.28 (0.22); and SS + rectangular: 4.22 (0.61). Significant effects of bracket types (P = 0.001) and archwire types (P = 0.000) on the friction force were detected using ANOVA. Tukey test indicated significant differences between PA brackets with both SS and MA brackets (P < 0.05), but not between SS and MA brackets. The two archwires as well had significantly different effects (Tukey P = 0.000). Conclusions: Based on the present in-vitro study, the PA brackets might create higher frictional forces compared to both SS and MA brackets. The rectangular 0.019 ×0.025 archwire might create greater forces than round 0.018 archwire. PMID:26020037

  18. Influence of bonding time on bond strength of metallic orthodontic bracket with etching base.%粘结时间对微蚀刻底托槽粘结强度的影响

    Institute of Scientific and Technical Information of China (English)

    杨瑞; 魏志民; 杨凯云; 张栋; 赵婧; 孙佩佩; 潘淑勤

    2012-01-01

    目的:对比微蚀刻底托槽粘结后不同时间的粘结强度,寻找合适的力的加载时机.方法:随机挑选对称性拔除上下颌第一前磨牙正畸患者30例,分为A、B、C三组进行全口微蚀刻底托槽粘结,分别在粘结后5 min,30 min,60min进行弓丝结扎,统计患者第一次复诊时托槽脱落率.将30例患者拔除的上颌第一前磨牙60颗,随机分成1~6组,每组10颗.1~6组离体牙粘结微蚀刻底直丝托槽,分别在粘结后5 min,10 min,15 min,30 min,60 min,24h进行抗剪切强度(SBS)测定,并统计粘结剂残留指数(ARI),扫描电镜观察托槽粘结前后底板形貌.结果:微蚀刻底托槽在体外粘结后24 h抗剪切强度达到最大.结论:微蚀刻底托槽的粘结强度能够满足临床需要,临床医师可在托槽粘结后5 min进行力的加载.%Objective: To measure the SBS of bracket with etching base at different time after bond and to find the appropriate time to load the bracket. Method: A total of 30 patients were randomly divided into 3 groups (10 per group) .480 bracket were bonded for them. They were loaded at 5 min,30 min,60 min seperately,and were observed for the first return visit.The failure of debond were recorded .Sixty youth maxillary first premolars extracted from the 30 patients above were randomly divided into 6 groups(10 per group). The shear bond test of group 1~6 was performed at different debond time of 5 min, 10 min, 15 min, 30 min, and 60 min and 24 hours. The chisquared test was used to determine signi? Cant differences for the ARI scores among the groups Ip < 0.05). Result: Highest shear bond strength was obtained with a debond time of 24 hours and the SBS was signi? Cantly different (P <0.001). Conclusion: Bracket with etching base is to meet the clinical requirement.lt is reliable to load the bracket 5 minutes after it is bonded.

  19. Frictional resistance of self-ligating versus conventional brackets in different bracket-archwire-angle combinations

    Directory of Open Access Journals (Sweden)

    Maria Regina Guerra MONTEIRO

    2014-06-01

    Full Text Available Objective: To compare the influence of archwire material (NiTi, beta-Ti and stainless steel and brackets design (self-ligating and conventional on the frictional force resistance. Material and Methods: Two types of brackets (self-ligating brackets - Smartclip, 3M/Unitek - and conventional brackets - Gemini, 3M/Unitek with three (0, 5, and 10 degrees slot angulation attached with elastomeric ligatures (TP Orthodontics were tested. All brackets were tested with archwire 0.019"x0.025" nickel-titanium, beta-titanium, and stainless steel (Unitek/3M. The mechanical testing was performed with a universal testing machine eMIC DL 10000 (eMIC Co, Brazil. The wires were pulled from the bracket slots at a cross-head speed of 3 mm/min until 2 mm displacement. Results: Self-ligating brackets produced significantly lower friction values compared with those of conventional brackets. Frictional force resistance values were directly proportional to the increase in the bracket/ wire angulation. With regard to conventional brackets, stainless steel wires had the lowest friction force values, followed by nickel-titanium and beta-titanium ones. With regard to self-ligating brackets, the nickel-titanium wires had the lowest friction values, significantly lower than those of other materials. Conclusion: even at different angulations, the self-ligating brackets showed significantly lower friction force values than the conventional brackets. Combined with nickel-titanium wires, the self-ligating brackets exhibit much lower friction, possibly due to the contact between nickel-titanium clips and wires of the same material.

  20. Avaliação do Índice de Remanescente Adesivo utilizando braquetes com e sem tratamento na base e a interação com três sistemas de colagem Evaluation of Adhesive Remnant Index using conventional mesh bases and sandblasted orthodontic bracket bases and three bonding systems

    Directory of Open Access Journals (Sweden)

    Lilian Maria Brisque Pignatta

    2009-02-01

    Full Text Available OBJETIVO: avaliar o Índice de Remanescente Adesivo (IRA em dentes bovinos após a descolagem de braquetes com e sem tratamento na base. METODOLOGIA: foram utilizados três sistemas de colagem ortodôntica para os dois padrões de base. Os dentes bovinos foram divididos em seis grupos de 40, de acordo com a base do braquete e o sistema de colagem. Vinte e quatro horas após a colagem foram realizados os testes de compressão em uma máquina de ensaios. A avaliação do IRA foi realizada em um estereomicroscópio por três examinadores calibrados. Foi utilizado o teste não paramétrico de Kruskal-Wallis, seguido do método de Dunn, para fazer as comparações múltiplas entre todos os grupos. RESULTADOS E CONCLUSÕES: observou-se que o tratamento das bases dos braquetes com óxido de alumínio não foi determinante para o aumento da adesividade entre o braquete e o adesivo. O grupo em que se utilizou braquetes com tratamento na base e adesivo TXT (3M-Unitek + Transbond Plus SEP (3M-Unitek apresentou a maior parte das fraturas na interface dente-adesivo (escore 4.AIM: To assess the Adhesive Remnant Index (ARI in bovine teeth after debonding mesh bases and sandblasted orthodontic bracket bases. METHODS: Were used three bonding systems for the two standards of base. The bovine teeth were divided into 6 groups of 40, according to the bracket base and to the bonding system. Twenty four hours after bonding they had been carried through shear bond strength tests in a universal testing machine. The assessment of ARI was performed in a stereomicroscopy by three calibrated examiners. It was used the non-parametric Kruskall-Wallis test, followed by Dunn's method, to do the multiple comparisons among all groups. RESULTS AND CONCLUSIONS: It was observed that the aluminum oxide sandblasting bracket bases was not determinative to the increase of the adhesiveness between bracket and adhesive. The group where it was used sandblasted orthodontic bracket bases and

  1. Comparison of Bond Strength of Metal and Ceramic Brackets Bonded with Conventional and High-Power LED Light Curing Units

    Science.gov (United States)

    Chalipa, Javad; Jalali, Yasamin Farajzadeh; Gorjizadeh, Fatemeh; Baghaeian, Pedram; Hoseini, Mohammad Hashem

    2016-01-01

    Objectives: The aim of this study was to evaluate the effect of conventional and high-power light emitting diode (LED) light curing units on shear bond strength (SBS) of metal and ceramic brackets to tooth surface. Materials and Methods: Forty sound bovine maxillary central incisors were used for the study. The teeth were divided into four groups (n=10). Teeth surfaces were etched with 37% phosphoric acid for 20 seconds. After applying a uniform layer of adhesive primer on the etched enamel, composite was placed on the base of brackets. The samples were light cured according to the manufacturer’s instructions and thermocycled. The SBS was measured. The failure mode was scored using the adhesive remnant index (ARI). Results: The mean SBS of samples in groups A (high-power LED, metal bracket), B (high-power LED, ceramic bracket), C (conventional LED, metal bracket) and D (conventional LED, ceramic bracket) was 23.1±3.69, 10.7±2.06, 24.92±6.37 and 10.74±3.18MPa, respectively. The interaction effect of type of LED unit (high-power/conventional) and bracket type on SBS was not statistically significant (P=0.483). In general, type of LED unit did not affect SBS. Type of bracket significantly affected SBS (P<0.001). The ARI score was not significantly influenced by the interaction between the type of LED unit and bracket. Conclusions: The obtained SBS is the same for both bracket types by use of high-power and conventional LED light curing units. Regardless of the type of LED unit, SBS of ceramic brackets was significantly lower than that of metal brackets.

  2. COMPARISON OF PERIODONTAL CONDITION BETWEEN CONVENTIONAL AND SELF-LIGATING BRACKETS%自锁托槽与传统托槽对正畸患者牙周健康影响的比较

    Institute of Scientific and Technical Information of China (English)

    李永花

    2015-01-01

    Objective To compareto impacts of self‐ligating brackets and conventional brackets on the periondontal health of the patient .Methods 50 patients (12 to 18 years old)were divided into 2 groups(group A :25 patients with self‐ligating brackets and group B :25 patients with conventional pre‐adjusted brackets) . Periodontal indices(GI ,PLl ,SBI and PD)were examined in both groups .Results Before treatment ,there is no significant difference between Group A and Group B .During the process of treatment ,PLI is statistical‐ly different between Group A and Group B ,other periodontal indices (GI ,SBI and PD) are not statistically different .Conclusion Although self‐ligating brackets is more beneficial for keeping oral hygiene ,but no significant difference were discovered on the patient’s periodontal health .%目的:比较自锁托槽与传统托槽对患者牙周健康的影响。方法选取12~18岁正畸患者50例,按矫治器类型分为两组:A组,25例戴用传统托槽矫治的患者;B组,25例戴用自锁托槽矫治的患者。分别于治疗前和治疗中1个月、3个月、6个月时检测两组患者的各项牙周指数(G I , PLI ,SBI ,PD)。结果矫治前,两组患者各项牙周指数无显著性差异( P >0.05);矫治过程中,两组患者的菌斑指数(PLI)有显著性差异( P <0.05),其余牙周指数(GI ,SBI ,PD)无显著性差异( P>0.05)。结论自锁托槽与传统托槽相比,在口腔卫生的维护方面更有优势,但二者对患者其他牙周健康的影响无明显区别。

  3. Are torque values of preadjusted brackets precise?

    Directory of Open Access Journals (Sweden)

    Alessandra Motta Streva

    Full Text Available OBJECTIVE: The aim of the present study was to verify the torque precision of metallic brackets with MBT prescription using the canine brackets as the representative sample of six commercial brands. MATERIAL AND METHODS: Twenty maxillary and 20 mandibular canine brackets of one of the following commercial brands were selected: 3M Unitek, Abzil, American Orthodontics, TP Orthodontics, Morelli and Ortho Organizers. The torque angle, established by reference points and lines, was measured by an operator using an optical microscope coupled to a computer. The values were compared to those established by the MBT prescription. RESULTS: The results showed that for the maxillary canine brackets, only the Morelli torque (-3.33º presented statistically significant difference from the proposed values (-7º. For the mandibular canines, American Orthodontics (-6.34º and Ortho Organizers (-6.25º presented statistically significant differences from the standards (-6º. Comparing the brands, Morelli presented statistically significant differences in comparison with all the other brands for maxillary canine brackets. For the mandibular canine brackets, there was no statistically significant difference between the brands. CONCLUSIONS: There are significant variations in torque values of some of the brackets assessed, which would clinically compromise the buccolingual positioning of the tooth at the end of orthodontic treatment.

  4. Are torque values of preadjusted brackets precise?

    Directory of Open Access Journals (Sweden)

    Alessandra Motta Streva

    2011-08-01

    Full Text Available OBJECTIVE: The aim of the present study was to verify the torque precision of metallic brackets with MBT prescription using the canine brackets as the representative sample of six commercial brands. MATERIAL AND METHODS: Twenty maxillary and 20 mandibular canine brackets of one of the following commercial brands were selected: 3M Unitek, Abzil, American Orthodontics, TP Orthodontics, Morelli and Ortho Organizers. The torque angle, established by reference points and lines, was measured by an operator using an optical microscope coupled to a computer. The values were compared to those established by the MBT prescription. RESULTS: The results showed that for the maxillary canine brackets, only the Morelli torque (-3.33º presented statistically significant difference from the proposed values (-7º. For the mandibular canines, American Orthodontics (-6.34º and Ortho Organizers (-6.25º presented statistically significant differences from the standards (-6º. Comparing the brands, Morelli presented statistically significant differences in comparison with all the other brands for maxillary canine brackets. For the mandibular canine brackets, there was no statistically significant difference between the brands. CONCLUSIONS: There are significant variations in torque values of some of the brackets assessed, which would clinically compromise the buccolingual positioning of the tooth at the end of orthodontic treatment.

  5. Strength Analysis and Process Simulation of Subway Contact Rail Support Bracket of Composite Materials

    Science.gov (United States)

    Fedulov, Boris N.; Safonov, Alexander A.; Sergeichev, Ivan V.; Ushakov, Andrey E.; Klenin, Yuri G.; Makarenko, Irina V.

    2016-10-01

    An application of composites for construction of subway brackets is a very effective approach to extend their lifetime. However, this approach involves the necessity to prevent process-induced distortions of the bracket due to thermal deformation and chemical shrinkage. At present study, a process simulation has been carried out to support the design of the production tooling. The simulation was based on the application of viscoelastic model for the resin. Simulation results were verified by comparison with results of manufacturing experiments. To optimize the bracket structure the strength analysis was carried out as well.

  6. Orthodontic bracket bonding to glazed full-contour zirconia

    OpenAIRE

    Kwak, Ji-Young; Jung, Hyo-Kyung; Choi, Il-Kyung; Kwon, Tae-Yub

    2016-01-01

    Objectives This study evaluated the effects of different surface conditioning methods on the bond strength of orthodontic brackets to glazed full-zirconia surfaces. Materials and Methods Glazed zirconia (except for the control, Zirkonzahn Prettau) disc surfaces were pre-treated: PO (control), polishing; BR, bur roughening; PP, cleaning with a prophy cup and pumice; HF, hydrofluoric acid etching; AA, air abrasion with aluminum oxide; CJ, CoJet-Sand. The surfaces were examined using profilometr...

  7. Longitudinal tibial epiphyseal bracket in Nievergelt syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Burnstein, M.I.; De Smet, A.A.; Breed, A.L.; Thomas, J.R.; Hafez, G.R.

    1989-04-01

    A patient is described with lower extremity mesomelic dwarfism associated with bilateral congenital elbow, hip, and knee dislocations. Rhomboid-shaped tibiae and delayed ossification of the primary fibular ossification centers were demonstrated at birth. Plain films and magnetic resonance imaging revealed that the tibial deformities were due to the presence of longitudinal epiphyseal brackets. These brackets were observed at surgery and confirmed histologically. Recognition of the longitudinal epiphyseal bracket and its relationship to the tibial deformities seen in this patient with Nievergelt syndrome is important for planning surgical treatment. (orig.).

  8. Poisson Bracket on the Space of Histories

    CERN Document Server

    Marolf, D

    1994-01-01

    We extend the Poisson bracket from a Lie bracket of phase space functions to a Lie bracket of functions on the space of canonical histories and investigate the resulting algebras. Typically, such extensions define corresponding Lie algebras on the space of Lagrangian histories via pull back to a space of partial solutions. These are the same spaces of histories studied with regard to path integration and decoherence. Such spaces of histories are familiar from path integration and some studies of decoherence. For gauge systems, we extend both the canonical and reduced Poisson brackets to the full space of histories. We then comment on the use of such algebras in time reparameterization invariant systems and systems with a Gribov ambiguity, though our main goal is to introduce concepts and techniques for use in a companion paper.

  9. Shear Bond Strength of Al2O3 Sandblasted Y-TZP Ceramic to the Orthodontic Metal Bracket

    Directory of Open Access Journals (Sweden)

    Seon Mi Byeon

    2017-02-01

    Full Text Available As the proportion of adult orthodontic treatment increases, mainly for aesthetic reasons, orthodontic brackets are directly attached to yttria-stabilized tetragonal zirconia polycrystal (Y-TZP restorations. This, study analyzed the shear bond strength (SBS between various surface treated Y-TZP and orthodontic metal brackets. The Y-TZP specimens were conditioned by 110 μm Al2O3 sandblasting, or sandblasting followed by coating with one of the primers (silane, MDP, or an MDP-containing silane primer. After surface treatment, the orthodontic metal bracket was bonded to the specimen using a resin cement, and then 24 h storage in water and thermal cycling (5000 cycles, 5–55 °C, SBS was measured. Surface roughness was analyzed for surface morphology, and X-ray photoelectron spectroscopy (XPS was employed for characterization of the chemical bond between the Y-TZP and the MDP-based primers (MDP, MDP containing silane primer. It was found that after surface treatment, the surface roughness of all groups increased. The groups treated with 110 μm Al2O3 sandblasting and MDP, or MDP-containing silane primer showed the highest SBS values, at 11.92 ± 1.51 MPa and 13.36 ± 2.31 MPa, respectively. The SBS values significantly decreased in all the groups after thermal cycling. Results from XPS analysis demonstrated the presence of chemical bonds between Y-TZP and MDP. Thus, the application of MDP-based primers after Al2O3 sandblasting enhances the resin bond strength between Y-TZP and the orthodontic metal bracket. However, bonding durability of all the surface-treated groups decreased after thermal cycling.

  10. Analysis of mesiodistal angulations of preadjusted brackets

    Directory of Open Access Journals (Sweden)

    Marcos Rogério de MENDONÇA

    2014-08-01

    Full Text Available Manufacturers offer various prescriptions of preadjusted brackets for use in the “straight-wire” orthodontic technique. However, the need to incorporate bends in the rectangular wires during orthodontic finishing has led to concerns regarding the type of prescription chosen and the credibility of information provided by the manufacturer. The aim of this study was to compare the slot angulations of Roth prescription preadjusted metallic brackets for the maxillary left central incisor and maxillary left canine. For each tooth type, 10 brackets of three commercial brands (GAC, Forestadent and Morelli were selected. Two individual metal matrices for brackets and tooth positioning were made for each group of teeth. Captured images were obtained by standardized ortho-radial photography with a digital camera. Images were exported and analyzed with the Image J software package. One-way ANOVA and Tukey statistical analyses were performed at the 5% significance level. For brackets of the maxillary left central incisor, differences in mean angulation were observed between the Morelli and GAC groups (p < 0.01 and between the Forestadent and GAC groups (p < 0.01. For brackets of the maxillary left canine, differences in mean angulation were found between the Morelli and GAC groups (p < 0.01 and between the Morelli and Forestadent groups (p < 0.05. In conclusion, despite their same prescription name, the different brands exhibited significantly different angulation measurements.

  11. Treatment time with self-ligating orthodontic brackets: a literature review

    OpenAIRE

    Claudino, Dikson; Philippi, Victor May

    2016-01-01

    AIM: The aim of this study was carry out a literature review on the self-ligating brackets (SLB), identifying publications which evaluated the treatment time with these systems comparing them to the conventional brackets (CB). MATERIAL AND METHODS: The following indexing bases were researched: Medline (Medicine online – International Literature on Health Sciences), LILACS (Latin-American and Caribbean Literature on Health Science), IBECS (Spanish Bibliographic on Health Sciences), SciELO (Sci...

  12. Uniform Approximation and Bracketing Properties of VC classes

    CERN Document Server

    Adams, Terrence M

    2010-01-01

    We show that the sets in a family with finite VC dimension can be uniformly approximated within a given error by a finite partition. Immediate corollaries include the fact that VC classes have finite bracketing numbers, satisfy uniform laws of averages under strong dependence, and exhibit uniform mixing. Our results are based on recent work concerning uniform laws of averages for VC classes under ergodic sampling.

  13. Comparacion de la resistencia al deslizamiento en brackets de autoligado y brackets convencionales ligados con ligadura elastomerica convencional y ligaduras de baja friccion.(brackets, ligadura elastomerica)

    National Research Council Canada - National Science Library

    Barrera Chaparro, Judith Patricia; Nieto Uribe, Mileny; Parra Mazo, Ivon Lilian; Gonzalez Caceres, Ernesto Jose; Rodriguez Quijada, Aleida Cristina

    2012-01-01

    .... El objetivo es comparar in vitro la RD de un tipo de bracket de autoligado con un tipo de bracket convencional combinado con ligaduras elastomericas de baja friccion y ligadura elastomerica convencional. Metodos...

  14. Resistance to Sliding in Clear and Metallic Damon 3 and Conventional Edge-wise Brackets: an In vitro Study

    Directory of Open Access Journals (Sweden)

    Mohammad Karim Soltani

    2015-03-01

    Full Text Available Statement of the Problem: Frictional forces are considered as important counter-force to orthodontic tooth movement. It is claimed that self-ligating brackets reduce the frictional forces. Purpose: The aim of this study was to compare the resistance to sliding in metallic and clear Damon brackets with the conventional brackets in a wet condition. Materials and Method: The samples included 4 types of brackets; metallic and clear Damon brackets and metallic and clear conventional brackets (10 brackets in each group. In this study, stainless steel wires sized 0.019×0.025 were em-ployed and the operator’s saliva was used to simulate the conditions of oral cavity. The tidy-modified design was used for simulation of sliding movement. The resistance to sliding and static frictional forces was measured by employing Testometric machine and load cell. Results: The mean (±SD of resistance to sliding was 194.88 (±26.65 and 226.62 (±39.9 g in the esthetic and metallic Damon brackets, while these values were 187.81(±27.84 and 191.17(±66.68 g for the clear and metallic conventional brackets, respectively. Static frictional forces were 206.4(±42.45 and 210.38(±15.89 g in the esthetic and metallic Damon brackets and 220.63(±49.29 and 215.13(±62.38 g in the clear and metallic conventional brackets. According to two-way ANOVA, no significant difference was observed between the two bracket materials (clear and metal and the two types of bracket (self-ligating versus conventional regarding resistance to sliding (p= 0.17 and p= 0.23, respectively and static frictional forces (p= 0.55 and p= 0.96, respectively. Conclusion: Neither the type of bracket materials nor their type of ligation made difference in resistance to sliding and static friction.

  15. Orthodontic bracket bonding to glazed full-contour zirconia

    Directory of Open Access Journals (Sweden)

    Ji-Young Kwak

    2016-05-01

    Full Text Available Objectives This study evaluated the effects of different surface conditioning methods on the bond strength of orthodontic brackets to glazed full-zirconia surfaces. Materials and Methods Glazed zirconia (except for the control, Zirkonzahn Prettau disc surfaces were pre-treated: PO (control, polishing; BR, bur roughening; PP, cleaning with a prophy cup and pumice; HF, hydrofluoric acid etching; AA, air abrasion with aluminum oxide; CJ, CoJet-Sand. The surfaces were examined using profilometry, scanning electron microscopy, and electron dispersive spectroscopy. A zirconia primer (Z-Prime Plus, Z or a silane primer (Monobond-S, S was then applied to the surfaces, yielding 7 groups (PO-Z, BR-Z, PP-S, HF-S, AA-S, AA-Z, and CJ-S. Metal bracket-bonded specimens were stored in water for 24 hr at 37℃, and thermocycled for 1,000 cycles. Their bond strengths were measured using the wire loop method (n = 10. Results Except for BR, the surface pre-treatments failed to expose the zirconia substructure. A significant difference in bond strengths was found between AA-Z (4.60 ± 1.08 MPa and all other groups (13.38 ± 2.57 - 15.78 ± 2.39 MPa, p < 0.05. For AA-Z, most of the adhesive remained on the bracket. Conclusions For bracket bonding to glazed zirconia, a simple application of silane to the cleaned surface is recommended. A zirconia primer should be used only when the zirconia substructure is definitely exposed.

  16. Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study.

    Science.gov (United States)

    Mirzakouchaki, Behnam; Shirazi, Sajjad; Sharghi, Reza; Shirazi, Samaneh; Moghimi, Mahsan; Shahrbaf, Shirin

    2016-02-01

    Different in-vitro studies have reported various results regarding shear bond strength (SBS) of orthodontic brackets when SEP technique is compared to conventional system. This in-vivo study was designed to compare the effect of conventional acid-etching and self-etching primer adhesive (SEP) systems on SBS and debonding characteristics of metal and ceramic orthodontic brackets. 120 intact first maxillary and mandibular premolars of 30 orthodontic patients were selected and bonded with metal and ceramic brackets using conventional acid-etch or self-etch primer system. The bonded brackets were incorporated into the wire during the study period to simulate the real orthodontic treatment condition. The teeth were extracted and debonded after 30 days. The SBS, debonding characteristics and adhesive remnant indices (ARI) were determined in all groups. The mean SBS of metal brackets was 10.63±1.42 MPa in conventional and 9.38±1.53 MPa in SEP system, (P=0.004). No statistically significant difference was noted between conventional and SEP systems in ceramic brackets. The frequency of 1, 2 and 3 ARI scores and debonding within the adhesive were the most common among all groups. No statistically significant difference was observed regarding ARI or failure mode of debonded specimens in different brackets or bonding systems. The SBS of metal brackets bonded using conventional system was significantly higher than SEP system, although the SBS of SEP system was clinically acceptable. No significant difference was found between conventional and SEP systems used with ceramic brackets. Total SBS of metal brackets was significantly higher than ceramic brackets. Due to adequate SBS of SEP system in bonding the metal brackets, it can be used as an alternative for conventional system. Shear bond strength, Orthodontic brackets, Adhesive remnant index, self-etch.

  17. Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study

    Science.gov (United States)

    Mirzakouchaki, Behnam; Sharghi, Reza; Shirazi, Samaneh; Moghimi, Mahsan; Shahrbaf, Shirin

    2016-01-01

    Background Different in-vitro studies have reported various results regarding shear bond strength (SBS) of orthodontic brackets when SEP technique is compared to conventional system. This in-vivo study was designed to compare the effect of conventional acid-etching and self-etching primer adhesive (SEP) systems on SBS and debonding characteristics of metal and ceramic orthodontic brackets. Material and Methods 120 intact first maxillary and mandibular premolars of 30 orthodontic patients were selected and bonded with metal and ceramic brackets using conventional acid-etch or self-etch primer system. The bonded brackets were incorporated into the wire during the study period to simulate the real orthodontic treatment condition. The teeth were extracted and debonded after 30 days. The SBS, debonding characteristics and adhesive remnant indices (ARI) were determined in all groups. Results The mean SBS of metal brackets was 10.63±1.42 MPa in conventional and 9.38±1.53 MPa in SEP system, (P=0.004). No statistically significant difference was noted between conventional and SEP systems in ceramic brackets. The frequency of 1, 2 and 3 ARI scores and debonding within the adhesive were the most common among all groups. No statistically significant difference was observed regarding ARI or failure mode of debonded specimens in different brackets or bonding systems. Conclusions The SBS of metal brackets bonded using conventional system was significantly higher than SEP system, although the SBS of SEP system was clinically acceptable. No significant difference was found between conventional and SEP systems used with ceramic brackets. Total SBS of metal brackets was significantly higher than ceramic brackets. Due to adequate SBS of SEP system in bonding the metal brackets, it can be used as an alternative for conventional system. Key words:Shear bond strength, Orthodontic brackets, Adhesive remnant index, self-etch. PMID:26855704

  18. Comparative study on direct and indirect bracket bonding techniques regarding time length and bracket detachment

    Directory of Open Access Journals (Sweden)

    Jefferson Vinicius Bozelli

    2013-12-01

    Full Text Available OBJECTIVE: The aim of this study was to assess the time spent for direct (DBB - direct bracket bonding and indirect (IBB - indirect bracket bonding bracket bonding techniques. The time length of laboratorial (IBB and clinical steps (DBB and IBB as well as the prevalence of loose bracket after a 24-week follow-up were evaluated. METHODS: Seventeen patients (7 men and 10 women with a mean age of 21 years, requiring orthodontic treatment were selected for this study. A total of 304 brackets were used (151 DBB and 153 IBB. The same bracket type and bonding material were used in both groups. Data were submitted to statistical analysis by Wilcoxon non-parametric test at 5% level of significance. RESULTS: Considering the total time length, the IBB technique was more time-consuming than the DBB (p < 0.001. However, considering only the clinical phase, the IBB took less time than the DBB (p < 0.001. There was no significant difference (p = 0.910 for the time spent during laboratorial positioning of the brackets and clinical session for IBB in comparison to the clinical procedure for DBB. Additionally, no difference was found as for the prevalence of loose bracket between both groups. CONCLUSION: the IBB can be suggested as a valid clinical procedure since the clinical session was faster and the total time spent for laboratorial positioning of the brackets and clinical procedure was similar to that of DBB. In addition, both approaches resulted in similar frequency of loose bracket.

  19. Avaliação da influência dos tipos de tratamento superficial da porcelana glazeada na colagem de braquetes ortodônticos Evaluation of the influence of porcelain conditioning techniques in orthodontic brackets bonding

    Directory of Open Access Journals (Sweden)

    Camila Belo Falcão

    2009-06-01

    Full Text Available OBJETIVO: o objetivo deste trabalho foi avaliar a influência do tipo de tratamento superficial da porcelana na resistência adesiva da colagem de braquetes ortodônticos e o modo de fratura após a descolagem. METODOLOGIA:foram confeccionados 80 corpos-de-prova de porcelana, divididos em quatro grupos (n = 18 de acordo com os diferentes tratamentos de superfície: (G1 ponta diamantada; (G2 ponta diamantada e silano; (G3 ácido hidrofluorídrico e (G4 ácido hidrofluorídrico e silano. Após o preparo das superfícies, braquetes Edgewise (Morelli foram colados com resina (Transbond XT, 3M e submetidos ao teste de cisalhamento. Os resultados foram avaliados estatisticamente pelo teste de Kruskal-Wallis. RESULTADO: o grupo G1 apresentou uma média de resistência de 3,35, o G2 3,97, o G3 2,56 e o G4 3,10. CONCLUSÃO: constatou-se que não houve diferença estatisticamente significativa na resistência adesiva do braquete entre os tipos de tratamentos estudados (p > 0,05 e os modos de fratura ocorreram, em sua grande maioria, na interface braquete/resina. Este estudo indica que todos os tipos de tratamentos apresentados são eficientes para a colagem.AIM: The aim of this study was to evaluate the influence of various porcelain surface treatments on the strength of orthodontic brackets bonded to porcelain and the fracture mode after debonding. METHODS: Eighty samples of porcelain were randomly divided into four groups according to their surface preparation, as follows: (G1 diamond bur, (G2 diamond bur with silane, (G3 hydrofluoridic acid and (G4 hydrofluoridic acid with silane. After surface treatment the Edgewise brackets (Morelli were bonded with resin (Transbond XT, 3M and sheared off. The Kruskal-Wallis statistical test were applied on the data. RESULTS: There were no statistically significant differences in bond strength between the groups (p > 0.05 and the fracture mode in most of the porcelain occurred in the composite/bracket interface. The

  20. On condition based maintenance policy

    Directory of Open Access Journals (Sweden)

    Jong-Ho Shin

    2015-04-01

    Full Text Available In the case of a high-valuable asset, the Operation and Maintenance (O&M phase requires heavy charges and more efforts than the installation (construction phase, because it has long usage life and any accident of an asset during this period causes catastrophic damage to an industry. Recently, with the advent of emerging Information Communication Technologies (ICTs, we can get the visibility of asset status information during its usage period. It gives us new challenging issues for improving the efficiency of asset operations. One issue is to implement the Condition-Based Maintenance (CBM approach that makes a diagnosis of the asset status based on wire or wireless monitored data, predicts the assets abnormality, and executes suitable maintenance actions such as repair and replacement before serious problems happen. In this study, we have addressed several aspects of CBM approach: definition, related international standards, procedure, and techniques with the introduction of some relevant case studies that we have carried out.

  1. Should the orthodontic brackets always be removed prior to magnetic resonance imaging (MRI)?

    Science.gov (United States)

    Poorsattar-Bejeh Mir, Arash; Rahmati-Kamel, Manouchehr

    2015-01-01

    Request for temporary removal of orthodontic appliances due to medical conditions that require magnetic resonance (MR) imaging is not uncommon in daily practice in the field of orthodontics. This may be at the expense of time and cost. Metal Orthodontic appliances cause more signal loss and image distortion as compared to ceramic and titanium ones. Stainless steel and large brackets in addition to the oriented miniscrews in relation to the axis of magnetic field may cause severe signal loss and image distortion. Moreover, gradient echo and frequency-selective fat saturation MR protocols are more susceptible to metal artifacts. The spin echo and fat-suppression protocols, low magnetic field strength (e.g., 1.5 Tesla vs. 3 Tesla), small field of view, high-resolution matrix, thin slice, increased echo train length and increased receiver band width could be applied to lessen the metal artifacts in MR images. The larger the distance between an appliance and desired location to be imaged, the lower the distortion and signal loss. Decision to remove brackets should be made based on its composition and desired anatomic location. In this review, first the principles of MR imaging are introduced (Part-I) and then the interactions of orthodontic appliances and magnetic field are farther discussed (Part-II). PMID:27195213

  2. Maslov indices, Poisson brackets, and singular differential forms

    Science.gov (United States)

    Esterlis, I.; Haggard, H. M.; Hedeman, A.; Littlejohn, R. G.

    2014-06-01

    Maslov indices are integers that appear in semiclassical wave functions and quantization conditions. They are often notoriously difficult to compute. We present methods of computing the Maslov index that rely only on typically elementary Poisson brackets and simple linear algebra. We also present a singular differential form, whose integral along a curve gives the Maslov index of that curve. The form is closed but not exact, and transforms by an exact differential under canonical transformations. We illustrate the method with the 6j-symbol, which is important in angular-momentum theory and in quantum gravity.

  3. 21 CFR 872.5470 - Orthodontic plastic bracket.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Orthodontic plastic bracket. 872.5470 Section 872...) MEDICAL DEVICES DENTAL DEVICES Therapeutic Devices § 872.5470 Orthodontic plastic bracket. (a) Identification. An orthodontic plastic bracket is a plastic device intended to be bonded to a tooth to...

  4. Shear bond strength of a novel silorane adhesive to orthodontic brackets and unprepared bovine enamel.

    Science.gov (United States)

    Brauchli, Lorenz; Steineck, Markus; Ball, Judith

    2013-02-01

    To evaluate the suitability of a novel epoxy-based resin, Filtek Silorane, for orthodontic bracket bonding on unprepared enamel. Shear forces to bovine enamel were measured for Filtek Silorane and Transbond XT in combination with steel, ceramic, and polymer brackets. For Filtek Silorane, etching was performed with the Silorane self-etching primer alone or an additional previous application of phosphoric acid. Transbond XT (conventional methacrylate) was used for the control group and the enamel was previously etched with 35% phosphoric acid. All samples were thermocycled (1000X, 5°to 55° C). Shear bond testing was done with an Instron 3344 at a crosshead speed of 1 mm/min. In addition, adhesive remnant index (ARI) scores were evaluated. The shear forces showed a weak adhesion of Filtek Silorane to unprepared enamel both with the selfetching primer and conventional etching (0.87 to 4.28 MPa). The shear forces of the control group were significantly higher (7.6 to 16.5 MPa). The ARI scores showed a clear failure at the enamel/adhesive interface for all Filtek Silorane samples. For the combination of Transbond XT and different brackets, the failure was found at the adhesive/bracket interface. The novel epoxy-based resin Filtek Silorane is not appropriate for bonding of brackets to unprepared enamel.

  5. A method for producing controlled fluoride release from an orthodontic bracket.

    Science.gov (United States)

    Li, Song; Hobson, Ross S; Bai, Yuxing; Yan, Zhuoqun; Carrick, Thomas E; McCabe, John F

    2007-12-01

    The aim of this study was to manufacture and test, in vitro, a novel modification to provide fluoride-releasing orthodontic brackets. Thirty-two orthodontic brackets were drilled to produce a recess (approximately 1.3 mm in diameter and 0.7 mm in depth) at the centre of the bracket base. Four materials, with and without the addition of sodium fluoride, a glass ionomer cement (Ketac Cem micro), a resin-modified glass ionomer cement (RMGIC; GC Fuji Ortho LC), a zinc phosphate (Zinc Cement Improved), and a resin (Transbond XT) were used to fill the recess in the bracket base. Fluoride release was measured daily during the first week and then weekly for 10 weeks. An ion chromatograph with suppressed conductivity was used for free fluoride ion determination. Statistical analysis to determine the amount of flouride release was undertaken using analysis of variance and Tukey's test. During the first 2 weeks, the resin group, with the addition of 38 per cent sodium fluoride added, released significantly more free fluoride (P < 0.05), but after 2 weeks the fluoride release markedly decreased. After 5 weeks, the RMGIC group, with 15 per cent added sodium fluoride, had significantly higher (P < 0.05) daily fluoride release than the other groups. The findings demonstrated that an appropriate fluoridated material can be used as a fluoride-releasing reservoir in a modified orthodontic bracket to enable it to release fluoride over the period of fixed appliance treatment.

  6. [In-vitro research on the thermal debonding of ceramic brackets].

    Science.gov (United States)

    Bäzner, B; Ettwein, K H; Röhlcke, F; Sernetz, F

    1991-12-01

    The mechanical debonding of ceramic brackets using special instruments involves the use of a degree of force that is damaging to the enamel. For this reason, the authors have developed the Ceramic Debonding Unit for the thermal debonding of ceramic brackets. The unit reduces the force necessary for debonding, without overheating the tooth. The present article explains the principle of the unit. The influence on the temperature increase in the pulpa of the mechanical torque applied during debonding, and the time taken for debonding was investigated in extracted teeth (lower central incisors). Tests on ceramic brackets made by various manufacturers showed that safe debonding is possible if the debonding time does not exceed 3 seconds at a torque of 100 Nnm. The temperature increase in the pulpa will not exceed 5 degrees C when the Ceramic Debonding Unit is used under these conditions, so that harmful overheating of healthy teeth does not occur.

  7. Whitham's Method and Dubrovin-Novikov Bracket in Single-Phase and Multiphase Cases

    Directory of Open Access Journals (Sweden)

    Andrei Ya. Maltsev

    2012-12-01

    Full Text Available In this paper we examine in detail the procedure of averaging of the local field-theoretic Poisson brackets proposed by B.A. Dubrovin and S.P. Novikov for the method of Whitham. The main attention is paid to the questions of justification and the conditions of applicability of the Dubrovin-Novikov procedure. Separate consideration is given to special features of single-phase and multiphase cases. In particular, one of the main results is the insensitivity of the procedure of bracket averaging to the appearance of ''resonances'' which can arise in the multi-phase situation.

  8. Assessment of the hardness of different orthodontic wires and brackets produced by metal injection molding and conventional methods.

    Science.gov (United States)

    Alavi, Shiva; Kachuie, Marzie

    2017-01-01

    This study was conducted to assess the hardness of orthodontic brackets produced by metal injection molding (MIM) and conventional methods and different orthodontic wires (stainless steel, nickel-titanium [Ni-Ti], and beta-titanium alloys) for better clinical results. A total of 15 specimens from each brand of orthodontic brackets and wires were examined. The brackets (Elite Opti-Mim which is produced by MIM process and Ultratrimm which is produced by conventional brazing method) and the wires (stainless steel, Ni-Ti, and beta-titanium) were embedded in epoxy resin, followed by grinding, polishing, and coating. Then, X-ray energy dispersive spectroscopy (EDS) microanalysis was applied to assess their elemental composition. The same specimen surfaces were repolished and used for Vickers microhardness assessment. Hardness was statistically analyzed with Kruskal-Wallis test, followed by Mann-Whitney test at the 0.05 level of significance. The X-ray EDS analysis revealed different ferrous or co-based alloys in each bracket. The maximum mean hardness values of the wires were achieved for stainless steel (SS) (529.85 Vickers hardness [VHN]) versus the minimum values for beta-titanium (334.65 VHN). Among the brackets, Elite Opti-Mim exhibited significantly higher VHN values (262.66 VHN) compared to Ultratrimm (206.59 VHN). VHN values of wire alloys were significantly higher than those of the brackets. MIM orthodontic brackets exhibited hardness values much lower than those of SS orthodontic archwires and were more compatible with NiTi and beta-titanium archwires. A wide range of microhardness values has been reported for conventional orthodontic brackets and it should be considered that the manufacturing method might be only one of the factors affecting the mechanical properties of orthodontic brackets including hardness.

  9. Analysis of Remote Weapon Station Bracket Stiffness,Strength and Fatigue Life Based on Virtual Prototype%基于虚拟样机的遥控武器站托架刚强度与疲劳寿命分析

    Institute of Scientific and Technical Information of China (English)

    毛保全; 梁博巍; 宋鹏

    2015-01-01

    Aiming at the practical problem that remote weapon station bracket which in fire system is under high load and measuring difficulties,based on remote weapon station virtual prototype,we explored analy-sis method of remote weapon station bracket stiffness,strength and fatigue life,and practiced it on a cer-tain type of remote controlled weapon station bracket,finally we got key problems of the analysis of remote weapon station bracket stiffness,strength and fatigue life. The analysis method could provide the theory reference on other core component.%针对遥控武器站火力系统中托架承受载荷较强与测量困难的实际问题,在遥控武器站虚拟样机的基础上,研究了遥控武器站托架的刚强度与疲劳寿命的分析方法,并实践于某型遥控武器站托架,最终得到了遥控武器站刚强度与疲劳寿命分析时应注意的重点问题。提出了适用于武器站托架的分析方法。分析方法可为其他关重件的刚强度校核与寿命分析提供理论参考与借鉴。

  10. Reduction in static friction by deposition of a homogeneous diamond-like carbon (DLC) coating on orthodontic brackets.

    Science.gov (United States)

    Akaike, Shun; Hayakawa, Tohru; Kobayashi, Daishiro; Aono, Yuko; Hirata, Atsushi; Hiratsuka, Masanori; Nakamura, Yoshiki

    2015-01-01

    In orthodontics, a reduction in static friction between the brackets and wire is important to enable easy tooth movement. The aim of this study was to examine the effects of a homogeneous diamond-like carbon (DLC) coating on the whole surfaces of slots in stainless steel orthodontic brackets on reducing the static friction between the brackets and the wire. The DLC coating was characterized using Raman spectroscopy, surface roughness and contact angle measurements, and SEM observations. Rectangular stainless steel and titanium-molybdenum alloy wires with two different sizes were employed, and the static friction between the brackets and wire was measured under dry and wet conditions. The DLC coating had a thickness of approximately 1.0 μm and an amorphous structure was identified. The results indicated that the DLC coating always led to a reduction in static friction.

  11. Effect of Four Methods of Surface Treatment on Shear Bond Strength of Orthodontic Brackets to Zirconium

    Science.gov (United States)

    Yassaei, Soghra; Aghili, Hossein Agha; Davari, Abdolrahim

    2015-01-01

    Objectives: Providing reliable attachment between bracket base and zirconia surface is a prerequisite for exertion of orthodontic force. The purpose of the present study was to evaluate the effect of four zirconium surface treatment methods on shear bond strength (SBS) of orthodontic brackets. Materials and Methods: One block of zirconium was trimmed into four zirconium surfaces, which served as our four study groups and each had 18 metal brackets bonded to them. Once the glazed layer was removed, the first group was etched with 9.6% hydrofluoric acid (HF), and the remaining three groups were prepared by means of sandblasting and 1W, and 2W Er: YAG laser, respectively. After application of silane, central incisor brackets were bonded to the zirconium surfaces. The SBS values were measured by a Dartec testing machine with a crosshead speed of 1 mm/min. Data were analyzed using one-way ANOVA and Tukey’s HSD for multiple comparisons. Results: The highest SBS was achieved in the sandblasted group (7.81±1.02 MPa) followed in a descending order by 2W laser group (6.95±0.87 MPa), 1W laser group (6.87±0.92 MPa) and HF acid etched group (5.84±0.78 MPa). The differences between the study groups were statistically significant except between the laser groups (Pacid etching for zirconium surface treatment prior to bracket bonding. PMID:26622283

  12. Effects of adhesion promoters on the shear bond strengths of orthodontic brackets to fluorosed enamel.

    Science.gov (United States)

    Adanir, Necdet; Türkkahraman, Hakan; Yalçin Güngör, Ahmet

    2009-06-01

    The aims of this in vitro study were to evaluate the effect of enamel fluorosis on the shear bond strength (SBS) of orthodontic brackets and to determine whether adhesion promoter, Enhance LC, increases the bond strength of brackets to fluorosed enamel. Forty-five (30 fluorosed and 15 non-fluorosed) non-carious fresh human premolar teeth, extracted for orthodontic reasons and without any caries or visible defects, were used in this study. The fluorosed teeth were selected according to the modified Thylstrup and Fejerskov index, which is based on the clinical changes in fluorosed teeth. In groups 1 (fluorosed teeth) and 3 (control), the brackets were bonded with Light Bond composite resin and cured with a halogen light. In group 2, Enhance LC was applied to fluorosed enamel before bonding. After bonding, the SBS of the brackets was tested with a universal testing machine. One-way analysis of variance and Tukey multiple comparison tests were used to compare the SBS of the groups. Any adhesive remaining after debonding was assessed and scored according to the modified adhesive remnant index. The results showed that while fluorosis significantly reduced the bond strengths of the orthodontic brackets (mean 13.94 +/- 3.24 MPa; P enamel (mean 18.22 +/- 5.97 Mpa; P enamel-composite interface.

  13. Translucency of Dental Ceramic, Post and Bracket

    Directory of Open Access Journals (Sweden)

    Yong-Keun Lee

    2015-10-01

    Full Text Available Translucency of dental ceramics, esthetic posts and orthodontic brackets was reviewed. Translucency parameter (TP and contrast ratio (CR are generally used for translucency evaluation. For the evaluation of translucency, two criteria such as the translucency of human teeth (TP = 15–19, 1 mm thick and the visual perceptibility threshold for the translucency difference (∆CR > 0.07 or ∆TP > 2 were used. In ceramics, translucency differences were in the perceptible range depending on the type of material and the thickness. However, variations caused by the difference in the required thickness for each layer by the material and also by the measurement protocols should be considered. As to the translucency of esthetic posts, a significant difference was found among the post systems. Translucency was influenced by the bracket composition and brand, and the differences by the brand were visually perceptible.

  14. Conceptual design for PSP mounting bracket

    Energy Technology Data Exchange (ETDEWEB)

    Ransom, G.; Stein, R. [Martin Marietta Energy Systems, Inc., Piketon, OH (United States)

    1991-12-31

    Protective structural packages (PSP`s or overpacks) used to ship 2 1/2-ton UF{sub 6} product cylinders are bolted to truck trailers. All bolts penetrate two longitudinal rows of wooden planks. Removal and replacement is required at various intervals for maintenance and routine testing. A conceptual design is presented for mounting brackets which would securely attach PSP`s to trailer frames, reduce removal and replacement time, and minimize risk of personnel injury.

  15. Toothpaste Prevents Debonded Brackets on Erosive Enamel

    Directory of Open Access Journals (Sweden)

    Érico Luiz Damasceno Barros

    2015-01-01

    Full Text Available This study evaluated the effect of high fluoride dentifrice on the bond strength of brackets after erosive challenge. Eighty-four enamel specimens were divided into seven groups (n=12: WN (distilled water/no acid challenge, W3C (distilled water/3 cycles of acid challenge, and W6C (distilled water/6 cycles of acid challenge were not submitted to dentifrice treatment. Groups RF3C (regular fluoride dentifrice/3 cycles of acid challenge and RF6C (regular fluoride dentifrice/6 cycles of acid challenge were treated with dentifrices containing 1450 μg F−/g and HF3C (high fluoride dentifrice/3 cycles of acid challenge and HF6C (high fluoride dentifrice/6 cycles of acid challenge were with 5000 μg F−/g. Acid challenges were performed for seven days. After bond strength test, there was no significant difference among groups submitted to 3 cycles of acid challenge (P>0.05. Statistically significant difference was found between the regular and high fluoride dentifrices after 6 cycles of acid challenge (<0.05. Similar areas of adhesive remaining were found among control groups and among groups W6C, RF3C, RF6C, HF3C, and HF6C. The high fluoride dentifrice was able to prevent the reduction of bond strength values of brackets submitted to acid challenge. Clinical relevance: the high fluoride toothpaste prevents debonded brackets on erosive enamel.

  16. Orthodontic bracket bonding to glazed full-contour zirconia

    Science.gov (United States)

    Kwak, Ji-Young; Jung, Hyo-Kyung; Choi, Il-Kyung

    2016-01-01

    Objectives This study evaluated the effects of different surface conditioning methods on the bond strength of orthodontic brackets to glazed full-zirconia surfaces. Materials and Methods Glazed zirconia (except for the control, Zirkonzahn Prettau) disc surfaces were pre-treated: PO (control), polishing; BR, bur roughening; PP, cleaning with a prophy cup and pumice; HF, hydrofluoric acid etching; AA, air abrasion with aluminum oxide; CJ, CoJet-Sand. The surfaces were examined using profilometry, scanning electron microscopy, and electron dispersive spectroscopy. A zirconia primer (Z-Prime Plus, Z) or a silane primer (Monobond-S, S) was then applied to the surfaces, yielding 7 groups (PO-Z, BR-Z, PP-S, HF-S, AA-S, AA-Z, and CJ-S). Metal bracket-bonded specimens were stored in water for 24 hr at 37℃, and thermocycled for 1,000 cycles. Their bond strengths were measured using the wire loop method (n = 10). Results Except for BR, the surface pre-treatments failed to expose the zirconia substructure. A significant difference in bond strengths was found between AA-Z (4.60 ± 1.08 MPa) and all other groups (13.38 ± 2.57 - 15.78 ± 2.39 MPa, p application of silane to the cleaned surface is recommended. A zirconia primer should be used only when the zirconia substructure is definitely exposed. PMID:27200278

  17. IN VITRO Cr(VI SPECIATION IN SYNTHETIC SALIVA AFTER RELEASING FROM ORTHODONTIC BRACKETS USING SILICA-APTES SEPARATION AND GF AAS DETERMINATION

    Directory of Open Access Journals (Sweden)

    Maciel S. Luz

    Full Text Available A method for Cr(VI speciation in synthetic saliva after releasing from orthodontic brackets, using silica nanoparticles organofunctionalized with (3-aminopropyltriethoxysilane (APTES for Cr(III/Cr(VI separation and GF AAS determination is proposed. Under the optimized conditions, Cr(VI speciation was performed using 150 mg of silica organofunctionalized with 2.0% (v v-1 of APTES at pH 8. It was observed different sensitivity when calibrations of GF AAS were performed using Cr(III or Cr(VI as standard solutions. Consequently, calibrations using stoichiometric mixtures (Cr(III + Cr(VI were used for total Cr determination and calibration using Cr(VI was used only for the determination of this specie. The reliability of the proposed silica-APTES separation procedure and GF AAS determination was checked by addition of both species in synthetic saliva. Recoveries ranging from 97 to 110% were obtained. The repeatability, based on the relative standard deviation (RSD inter days was less than 6%. A corrosion test was carried out on 20 orthodontic brackets from two different models, after immersion in synthetic saliva (pH=6.0 at 37 °C with agitation (125 rpm for 24 h. It was observed that about 40% of the total chromium released from the analyzed orthodontic brackets was Cr(VI.

  18. Alterations in plaque accumulation and gingival inflammation promoted by treatment with self-ligating and conventional orthodontic brackets

    Directory of Open Access Journals (Sweden)

    Mauricio de Almeida Cardoso

    2015-04-01

    Full Text Available OBJECTIVE: The aim of the present study was to evaluate, comparatively, the periodontal response during orthodontic treatment performed with self-ligating and conventional brackets. METHODS: Sixteen Caucasian individuals of both sexes, aged between 12 and 16 years old and in permanent dentition were selected. Eight individuals were treated with conventional brackets installed on the lower dental arch and self-ligating brackets on the upper arch. Another eight individuals received self-ligating brackets in the lower arch and conventional brackets in the upper arch. The subjects received material and instructions for oral hygiene. Visible plaque index (VPI, gingival bleeding index (GBI and clinical attachment level (CAL were evaluated just after installation of orthodontic appliances, and 30, 60 and 180 days later. Mann-Whitney test was used to compare differences between groups (self-ligating and conventional, two-way ANOVA followed by Tukey's test was used to assess CAL at each site of each tooth. Significance level was set at 5%. RESULTS: No significant changes were found with regard to the assessed parameters (VPI, GBI and CAL in either one of the systems. CONCLUSION: No significant changes were found with regard to the periodontal response to orthodontic treatment for the variables assessed and between subjects receiving passive self-ligating and conventional brackets. All individuals had received oral hygiene instructions and had their periodontal conditions monitored.

  19. A comparative assessment of torque generated by lingual and conventional brackets

    NARCIS (Netherlands)

    Sifakakis, I.; Pandis, N.; Makou, M.; Eliades, T.; Katsaros, C.; Bourauel, C.

    2013-01-01

    The aim of this study was to assess the effect of bracket type on the labiopalatal moments generated by lingual and conventional brackets. Incognito lingual brackets (3M Unitek), STb lingual brackets (Light Lingual System; ORMCO), In-Ovation L lingual brackets (DENTSPLY GAC), and conventional 0.018

  20. Higher derived brackets, strong homotopy associative algebras and Loday pairs

    CERN Document Server

    Uchino, K

    2009-01-01

    We give a quick method of constructing strong homotopy associative algebras. This method is an associative version of (higher) derived bracket construction in the category of Lie/Leibniz algebras. We try to unify the two derived bracket constructions. For that aim we introduce a new type of algebra ``Loday pair", which is a noncommutative version of classical Leibniz pair. We give a coalgebra description of Loday pairs and study a derived bracket construction for Loday pairs.

  1. Effects of delayed polymerization time and bracket manipulation on orthodontic resin modified glass ionomer adhesive

    Science.gov (United States)

    Gilbert, Danielle Wiggins

    This study examined the effect of varying delayed polymerization times in combination with bracket manipulation on shear bond strength (SBS), degree of conversion (DC), and adhesive remnant index (ARI) score when using a resin modified glass ionomer (RMGI) adhesive. Specimens were divided into three groups of clinically relevant delay times (0.5, 2, and 4-min) to simulate the delay that frequently occurs between bracket placement and manipulation and subsequent light curing. Based on an analysis of variance (alpha=.05), the SBS was not significantly different between the three groups. While one of the goals of this study was to be the first study to quantify DC of RMGI using Raman microspectroscopy, several challenges, including weak peak signal with and without fluorescence, were encountered and as a result, DC could not be determined. A significant difference (p<0.05) in ARI score was detected between the 0.5-min and 4.0-min delay groups with more adhesive remaining on the bracket with increasing delay time. A Spearman correlation between SBS and ARI indicated no positive association between SBS and ARI measures across delay times. The results of this study suggest that clinically relevant delay times of 0.5, 2, and 4-min do not negatively impact the SBS of a RMGI adhesive. However, with increasing delay time, the results suggest that more adhesive might remain on the bracket during debonding. With more adhesive remaining on the bracket, this could be beneficial in that less adhesive needs to be removed from enamel by grinding at the time of bracket removal when orthodontic treatment is completed.

  2. Assessment of dimensional accuracy of preadjusted metal injection molding orthodontic brackets

    Directory of Open Access Journals (Sweden)

    Shiva Alavi

    2016-01-01

    Full Text Available Background: the aim of this study is to evaluate the dimensional accuracy of McLaughlin, Bennett, and Trevisi (MBT brackets manufactured by two different companies (American Orthodontics and Ortho Organizers and determine variations in incorporation of values in relation to tip and torque in these products. Materials and Methods: In the present analytical/descriptive study, 64 maxillary right central brackets manufactured by two companies (American Orthodontics and Ortho Organizers were selected randomly and evaluated for the accuracy of the values in relation to torque and angulation presented by the manufacturers. They were placed in a video measuring machine using special revolvers under them and were positioned in a manner so that the light beams would be directed on the floor of the slot without the slot walls being seen. Then, the software program of the same machine was used to determine the values of each bracket type. The means of measurements were determined for each sample and were analyzed with independent t-test and one-sample t-test. Results: Based on the confidence interval, it can be concluded that at 95% probability, the means of tip angles of maxillary right central brackets of these two brands were 4.1-4.3° and the torque angles were 16.39-16.72°. The tips in these samples were at a range of 3.33-4.98°, and the torque was at a range of 15.22-18.48°. Conclusion: In the present study, there were no significant differences in the angulation incorporated into the brackets from the two companies; however, they were significantly different from the tiP values for the MBT prescription. In relation to torque, there was a significant difference between the American Orthodontic brackets exhibited significant differences with the reported 17°, too.

  3. Assessment of dimensional accuracy of preadjusted metal injection molding orthodontic brackets

    Science.gov (United States)

    Alavi, Shiva; Tajmirriahi, Farnaz

    2016-01-01

    Background: the aim of this study is to evaluate the dimensional accuracy of McLaughlin, Bennett, and Trevisi (MBT) brackets manufactured by two different companies (American Orthodontics and Ortho Organizers) and determine variations in incorporation of values in relation to tip and torque in these products. Materials and Methods: In the present analytical/descriptive study, 64 maxillary right central brackets manufactured by two companies (American Orthodontics and Ortho Organizers) were selected randomly and evaluated for the accuracy of the values in relation to torque and angulation presented by the manufacturers. They were placed in a video measuring machine using special revolvers under them and were positioned in a manner so that the light beams would be directed on the floor of the slot without the slot walls being seen. Then, the software program of the same machine was used to determine the values of each bracket type. The means of measurements were determined for each sample and were analyzed with independent t-test and one-sample t-test. Results: Based on the confidence interval, it can be concluded that at 95% probability, the means of tip angles of maxillary right central brackets of these two brands were 4.1–4.3° and the torque angles were 16.39–16.72°. The tips in these samples were at a range of 3.33–4.98°, and the torque was at a range of 15.22–18.48°. Conclusion: In the present study, there were no significant differences in the angulation incorporated into the brackets from the two companies; however, they were significantly different from the tiP values for the MBT prescription. In relation to torque, there was a significant difference between the American Orthodontic brackets exhibited significant differences with the reported 17°, too. PMID:27857770

  4. Dentoalveolar mandibular changes with self-ligating versus conventional bracket systems: A CBCT and dental cast study

    Directory of Open Access Journals (Sweden)

    Marcio Rodrigues de Almeida

    2015-06-01

    Full Text Available OBJECTIVE: The aim of the present study was to compare dentoalveolar changes in mandibular arch, regarding transversal measures and buccal bone thickness, in patients undergoing the initial phase of orthodontic treatment with self-ligating or conventional bracket systems. METHODS: A sample of 25 patients requiring orthodontic treatment was assessed based on the bracket type. Group 1 comprised 13 patients bonded with 0.022-in self-ligating brackets (SLB. Group 2 included 12 patients bonded with 0.022-in conventional brackets (CLB. Cone-beam computed tomography (CBCT scans and a 3D program (Dolphin assessed changes in transversal width of buccal bone (TWBB and buccal bone thickness (BBT before (T1 and 7 months after treatment onset (T2. Measurements on dental casts were performed using a digital caliper. Differences between and within groups were analyzed by Student's t-test; Pearson correlation coefficient was also calculated. RESULTS: Significant mandibular expansion was observed for both groups; however, no significant differences were found between groups. There was significant decrease in mandibular buccal bone thickness and transversal width of buccal bone in both groups. There was no significant correlation between buccal bone thickness and dental arch expansion. CONCLUSIONS: There were no significant differences between self-ligating brackets and conventional brackets systems regarding mandibular arch expansion and changes in buccal bone thickness or transversal width of buccal bone.

  5. The quaternionic commutator bracket and its implications

    CERN Document Server

    Arbab, Arbab I

    2014-01-01

    A quaternionic commutator bracket for position and momentum shows that the quaternionic wave function, \\emph{viz.} $\\widetilde{\\psi}=(\\frac{i}{c}\\,\\psi_0\\,,\\vec{\\psi})$, represents a state of a particle with orbital angular momentum, $L=3\\,\\hbar$, resulting from the internal structure of the particle. This angular momentum can be attributed to spin of the particle. The vector $\\vec{\\psi}$, points along the direction of $\\vec{L}$. When a charged particle is placed in an electromagnetic fields the interaction energy reveals that the magnetic moments interact with the electric and magnetic fields giving rise to terms similar to Aharonov-Bohm and Aharonov-Casher effects.

  6. Maintenance and Condition-Based Maintenance

    Institute of Scientific and Technical Information of China (English)

    DING Jin-hua; WANG Xue-Jun; ZHOU Rong; LIN Min; Olsson Erland

    2005-01-01

    The evolution of maintenance management is briefly introduced in this paper, from corrective maintenance to preventive maintenance. First, a range of condition monitoring and fault diagnosis techniques developed in different industries are surveyed; Second, many methods of condition monitoring are presented; Third, mathematical methods used in condition monitoring are given; Then the merits and shortcomings are discussed.Efficient maintenance policies are of fundamental importance in system engineering because of their fallbacks into the safety and economics of plant operation. Applying condition-based maintenance to a system can reduce the cost and extend the availability of facilities. With the advent of personal computers as fast and cost effective machines for data acquisition and processing of multiple signals some shortcomings mentioned in condition monitoring could be solved or reduced to some extent. These PCs can be a solution as a condition monitoring based maintenance system.

  7. Experimental Aspects in the Vibration-Based Condition Monitoring of Large Hydrogenerators

    Directory of Open Access Journals (Sweden)

    Geraldo Carvalho Brito Junior

    2017-01-01

    Full Text Available Based on experimental observations on a set of twenty 700 MW hydrogenerators, compiled from several technical reports issued over the last three decades and collected from the reprocessing of the vibration signals recorded during the last commissioning tests, this paper shows that the accurate determination of the journal bearings operating conditions may be a difficult task. It shows that the outsize bearing brackets of large hydrogenerators are subject to substantial dimensional changes caused by external agents, like the generator electromagnetic field and the bearing cooling water temperature. It also shows that the shaft eccentricity of a journal bearing of a healthy large hydrogenerator, operating in steady-state condition, may experience unpredictable, sudden, and significant changes without apparent reasons. Some of these phenomena are reproduced in ordinary commissioning tests or may be noticed even during normal operation, while others are rarely observed or are only detected through special tests. These phenomena modify journal bearings stiffness and damping, changing the hydrogenerator dynamics, creating discrepancies between theoretical predictions and experimental measurements, and making damage detection and diagnostics difficult. Therefore, these phenomena must be analyzed and considered in the application of vibration-based condition monitoring to these rotating machines.

  8. Precision forging technologies for magnesium alloy bracket and wheel

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Fundamental investigations on precision forging technology of magnesium alloys were studied. As-cast billet prestraining and a new concept of hollow billet were proposed in order to reduce the maximum forming load. A scheme of isothermal forming and the use of combined female dies were adopted, which can improve the die filling capacity and ensure the manufacture of high quality forgings. By means of the developed technique, AZ80 alloy wheel and AZ31 alloy bracket were produced successfully at suitable process parameters and applied in the automotive industries. The results show that the hot compression of AZ80 magnesium alloy has the peak flow stresses of pre-strained alloy with finer grain, which are lower by 20% than those of as-cast alloy under the same deformation conditions. The forming load is related to contact area and average positive stress on interface during forging process.

  9. Influence of microhybrid resin and etching times on bleached enamel for the bonding of ceramic brackets.

    Science.gov (United States)

    Firoozmand, Leily Macedo; Brandão, Juliana Viana Pereira; Fialho, Melissa Proença Nogueira

    2013-01-01

    The aim of this study was to evaluate the shear bond strength (SBS) of polycrystalline ceramic brackets (PCB) bonded after bleaching treatment using different composite resins and enamel etching times. A total of 144 bovine incisors were randomly divided into two study groups (n = 72, each) as follows: G1, enamel bleached with 35% hydrogen peroxide, and G2 (control group), enamel unbleached. After the bleaching treatment, the samples were stored in artificial saliva for 14 days. These groups were further divided into two subgroups (n = 36, each) as follows: GA, brackets bonded with Transbond XT (3M) and GB, brackets bonded with Filtek Z250 (3M). For each resin used, three different etching times with 37% phosphoric acid (15, 30 and 60 seconds) were tested. SBS tests were performed using a universal testing machine (EMIC), and the adhesive remnant index (ARI) score was verified. Significant differences among the three experimental conditions and interactions between the groups were observed. The type of composite resin accounted for 24% of the influence on the bond strength, whereas the etching time and bleaching treatment accounted for 14.5% and 10% of the influence on bond strength, respectively. The ARI revealed that the most common area of adhesion failure was at the composite resin-bracket interface. The type of composite resin, etching time and external bleaching significantly influenced the SBS of PCB on enamel, even after 14 days of saliva storage.

  10. Influence of microhybrid resin and etching times on bleached enamel for the bonding of ceramic brackets

    Directory of Open Access Journals (Sweden)

    Leily Macedo Firoozmand

    2013-04-01

    Full Text Available The aim of this study was to evaluate the shear bond strength (SBS of polycrystalline ceramic brackets (PCB bonded after bleaching treatment using different composite resins and enamel etching times. A total of 144 bovine incisors were randomly divided into two study groups (n = 72, each as follows: G1, enamel bleached with 35% hydrogen peroxide, and G2 (control group, enamel unbleached. After the bleaching treatment, the samples were stored in artificial saliva for 14 days. These groups were further divided into two subgroups (n = 36, each as follows: GA, brackets bonded with Transbond XT (3M and GB, brackets bonded with Filtek Z250 (3M. For each resin used, three different etching times with 37% phosphoric acid (15, 30 and 60 seconds were tested. SBS tests were performed using a universal testing machine (EMIC, and the adhesive remnant index (ARI score was verified. Significant differences among the three experimental conditions and interactions between the groups were observed. The type of composite resin accounted for 24% of the influence on the bond strength, whereas the etching time and bleaching treatment accounted for 14.5% and 10% of the influence on bond strength, respectively. The ARI revealed that the most common area of adhesion failure was at the composite resin-bracket interface. The type of composite resin, etching time and external bleaching significantly influenced the SBS of PCB on enamel, even after 14 days of saliva storage.

  11. Shear bond strength of self-ligating orthodontic brackets on different types of porcelain crowns

    Directory of Open Access Journals (Sweden)

    Karamdeep Singh Ahluwalia

    2013-01-01

    Full Text Available Aim: The aim of this study is to compare shear bond strength (SBS and adhesive remnant index (ARI of self-ligating orthodontic brackets bonded to different porcelain crowns. Materials and Methods: Three groups of different types of porcelain crowns, each containing 12 crowns were fabricated by the same technician and allocated to one of the study groups as follows: Group I - IPS porcelain crowns (Ivoclar Vivadent AG, Schaan, Liechtenstein, Group II - Porcelain fused to zirconia crowns (Zirkonzahn GmbH, Gais, Italy, Noritake Co., Tokyo, Japan and Group III - Conventional porcelain fused to metal crowns (Ceramco3, Densply, PA, USA. The orthodontic brackets were bonded to these crowns using hydrofluoric acid (HFA + silane etching protocol. After bonding, the SBS of the brackets were tested with a universal testing machine under standard test conditions. Results: Statistical evaluation using analysis of variance showed a significant difference between the groups (P 0.05. Chi-square comparison revealed no significant difference in ARI scores between groups (P > 0.05. Conclusions: When HFA + silane etching protocol were used, IPS crowns showed the greatest SBS of orthodontic brackets. The ARI score was non-significant. Therefore, if there is a need to place crowns over teeth then these crowns can be used for restoration of teeth before orthodontic treatment.

  12. Magnetic resonance imaging artifacts caused by brackets of various materials - An in vivo study

    OpenAIRE

    Deepti Razdan; Rani, M S

    2012-01-01

    Objectives: To evaluate and compare the artifacts caused by various brackets materials on Magnetic Resonance Imaging (MRI). Materials and Methods: Six cases were included - one control case, one case each with teeth bonded in the maxillary arch with composite brackets, ceramic brackets, stainless steel brackets, ceramic brackets in the maxillary anterior region and stainless steel brackets in the premolar region, and one case with teeth bonded in the maxillary and mandibular arch wit...

  13. Bonding brackets to porcelain: in vitro study

    Directory of Open Access Journals (Sweden)

    Sant'Anna Eduardo Franzotti

    2002-01-01

    Full Text Available The aim of this research was to verify, in vitro, the effect of various porcelain surface treatments on the shear strength of orthodontic brackets bonded to porcelain and the mode of fracture after debonding. Eighty-eight samples of metallic supported feldspathic porcelain were randomly divided into four groups according to their surface preparation as follows: the porcelain was maintained intact (GI, roughened with a diamond bur (GII, etched with 10% hydrofluoric acid (GIII, or sandblasted with aluminum oxide (GIV. The specimens were treated with silane (Scothprime and brackets were bonded with Concise. Each sample was subjected to a shear load at a crosshead speed of 1 mm/min and a recording was made at the point of failure. Bond strengths, adequate to withstand the application of orthodontic forces, were achieved in all groups. The Kruskal-Wallis statistical test showed no significant differences in bond strength between the groups (p>0.05. However, many more porcelain fractures occurred on deglazed porcelain. This study indicates that with the appropriate material selection, the silane/composite procedure alone may be adequate for bonding.

  14. Causal Poisson bracket via deformation quantization

    Science.gov (United States)

    Berra-Montiel, Jasel; Molgado, Alberto; Palacios-García, César D.

    2016-06-01

    Starting with the well-defined product of quantum fields at two spacetime points, we explore an associated Poisson structure for classical field theories within the deformation quantization formalism. We realize that the induced star-product is naturally related to the standard Moyal product through an appropriate causal Green’s functions connecting points in the space of classical solutions to the equations of motion. Our results resemble the Peierls-DeWitt bracket that has been analyzed in the multisymplectic context. Once our star-product is defined, we are able to apply the Wigner-Weyl map in order to introduce a generalized version of Wick’s theorem. Finally, we include some examples to explicitly test our method: the real scalar field, the bosonic string and a physically motivated nonlinear particle model. For the field theoretic models, we have encountered causal generalizations of the creation/annihilation relations, and also a causal generalization of the Virasoro algebra for the bosonic string. For the nonlinear particle case, we use the approximate solution in terms of the Green’s function, in order to construct a well-behaved causal bracket.

  15. Simulation and experimental validation of powertrain mounting bracket design obtained from multi-objective topology optimization

    OpenAIRE

    Qinghai Zhao; Xiaokai Chen; Lu Wang; Jianfeng Zhu; Zheng-Dong Ma; Yi Lin

    2015-01-01

    A framework of multi-objective topology optimization for vehicle powertrain mounting bracket design with consideration of multiple static and dynamic loading conditions is developed in this article. Incorporating into the simplified isotropic material with penalization model, compromise programming method is employed to describe the multi-objective and multi-stiffness topology optimization under static loading conditions, whereas mean eigenvalue formulation is proposed to analyze vibration op...

  16. HOTB update: Parallel code for calculation of three- and four-particle harmonic oscillator transformation brackets and their matrices using OpenMP

    Science.gov (United States)

    Germanas, D.; Stepšys, A.; Mickevičius, S.; Kalinauskas, R. K.

    2017-06-01

    This is a new version of the HOTB code designed to calculate three and four particle harmonic oscillator (HO) transformation brackets and their matrices. The new version uses the OpenMP parallel communication standard for calculations of harmonic oscillator transformation brackets. A package of Fortran code is presented. Calculation time of large matrices, orthogonality conditions and array of coefficients can be significantly reduced using effective parallel code. Other functionalities of the original code (for example calculation of single harmonic oscillator brackets) have not been modified.

  17. The Evaluation of a Resin-modified Glass Ionome Cement for Bonding Orthodontic Brackets

    Institute of Scientific and Technical Information of China (English)

    LI Fujun; PENG Youjian; PENG Bin

    2009-01-01

    To evaluate the shear bond strength(SBS)and bond failure interface after the debonding of orthodontic brackets with a resin-modified glass ionomer cement(RMGIC)under six bonding conditions,140 premolar teeth were randomly divided into seven groups.The brackets of all groups,except for control group,were bonded using a RMGIC.The teeth were debonded using a universal testing machine.The shear bond strength,adhesive remnant index(ARI)and enamel fracture were examined for each debonding.A significant difference existed in SBS under wet and dry condi-tions in two groups of Fuji Ortho LC.Different degree of enamel fracture was seen in groups of Fuji Ortho LC(dry/37%phosphoric acid treated)after debonding.Bond failed predominantly at the enamel-adhesive interface,except for phosphoric acid treated groups.The RMGIC achieve a clinically effective adhesion in orthodontics under different bonding conditions.

  18. Dental Hygiene and Orthodontics: Effect of Ultrasonic Instrumentation on Bonding Efficacy of Different Lingual Orthodontic Brackets

    Science.gov (United States)

    Collesano, Vittorio; Tovt, Gaia; Bernardinelli, Luisa; Gandini, Paola

    2017-01-01

    Dental hygienists are often faced with patients wearing lingual orthodontic therapy, as ultrasonic instrumentation (UI) is crucial for oral health. As the application of external forces can lead to premature bonding failure, the aim of this study was to evaluate the effect of UI on shear bond strength (SBS) and on adhesive remnant index (ARI) of different lingual orthodontic brackets. 200 bovine incisors were divided into 10 groups. Four different lingual (STB, Ormco; TTR, Rocky Mountain Orthodontics; Idea, Leone; 2D, Forestadent) and vestibular control (Victory, 3M) brackets were bonded. UI was performed in half of specimens, whereas the other half did not receive any treatment. All groups were tested with a universal testing machine. SBS and ARI values were recorded. Statistical analysis was performed (significance: P = 0.05). TTR, Idea, and 2D lingual brackets significantly lowered SBS after UI, whereas for other braces no effect was recorded. Appliances with lower mesh area significantly reduced their adhesion capacity after UI. Moreover groups subjected to UI showed higher ARI scores than controls. UI lowered SBS of lingual appliances of small dimensions so particular care should be posed avoiding prolonged instrumentation around bracket base during plaque removal. Moreover, UI influenced also ARI scores. PMID:28904955

  19. On the compatible weakly nonlocal Poisson brackets of hydrodynamic type

    Directory of Open Access Journals (Sweden)

    Andrei Ya. Maltsev

    2002-01-01

    of hydrodynamic type (Ferapontov brackets and the corresponding integrable hierarchies. We show that, under the requirement of the nondegeneracy of the corresponding “first” pseudo-Riemannian metric g(0 νμ and also some nondegeneracy requirement for the nonlocal part, it is possible to introduce a “canonical” set of “integrable hierarchies” based on the Casimirs, momentum functional and some “canonical Hamiltonian functions.” We prove also that all the “higher” “positive” Hamiltonian operators and the “negative” symplectic forms have the weakly nonlocal form in this case. The same result is also true for “negative” Hamiltonian operators and “positive” symplectic structures in the case when both pseudo-Riemannian metrics g(0 νμ and g(1 νμ are nondegenerate.

  20. Shear bond strength of metallic brackets: influence of saliva contamination

    Directory of Open Access Journals (Sweden)

    Luciana Borges Retamoso

    2009-06-01

    Full Text Available OBJECTIVE: To evaluate the influence of saliva contamination on shear bond strength and the bond failure pattern of 3 adhesive systems (Transbond XT, AdheSE and Xeno III on orthodontic metallic brackets bonded to human enamel. MATERIAL AND METHODS: Seventy-two permanent human molars were cut longitudinally in a mesiodistal direction, producing seventy-two specimens randomly divided into six groups. Each system was tested under 2 different enamel conditions: no contamination and contaminated with saliva. In T, A and X groups, the adhesive systems were applied to the enamel surface in accordance with manufacturer's instructions. In TS, AS and XS groups, saliva was applied to enamel surface followed by adhesive system application. The samples were stored in distilled water at 37ºC for 24 h, and then tested for shear bond strength in a universal testing machine (Emic, DL 2000 running at a crosshead speed of 1 mm/min. After bond failure, the enamel surfaces were observed under an optical microscope at 40x magnification. RESULTS: The control and contaminated groups showed no significant difference in shear bond strength for the same adhesive system. However, shear bond strength of T group (17.03±4.91 was significantly higher than that of AS (8.58±1.73 and XS (10.39±4.06 groups (p<0.05. Regarding the bond failure pattern, TS group had significantly higher scores of no adhesive remaining on the tooth in the bonding area than other groups considering the adhesive remnant index (ARI used to evaluate the amount of adhesive left on the enamel. CONCLUSIONS: Saliva contamination showed little influence on the 24-h shear bond strength of orthodontic brackets.

  1. Evaluation of shear bond strength of different treatments of ceramic bracket surfaces Avaliação da resistência ao cisalhamento de diferentes tratamentos na superfície de braquetes cerâmicos

    Directory of Open Access Journals (Sweden)

    Patrícia Helou Ramos Andrade

    2012-08-01

    Full Text Available OBJECTIVE: To evaluate the bonding strength of the ceramic bracket and composite resin restoration interface, using four types of treatment on the base of the bracket. METHODOLOGY: 48 photoactivated composite resin discs were used (FiltekTM Z250 contained in specimens and divided into 4 groups of 12 specimens for each group according to the type of treatment performed on the base of the brackets. Once the brackets were bonded, the specimens were subjected to shear stress carried out in a universal testing machine (MTS: 810 Material Test System calibrated with a fixed speed of 0.5 mm / minute. The values obtained were recorded and compared by means of appropriate statistical tests - analysis of variance and then Tukey's test. RESULTS AND CONCLUSIONS: The surfaces of ceramic brackets conditioned with 10% hydrofluoric acid for 1 minute, followed by aluminum oxide blasting, 50µ, after silane application and primer application, was considered the best method to prepare surfaces of ceramic brackets prior to orthodontic esthetic bonding.OBJETIVO: avaliar a resistência à união da interface entre braquete cerâmico e restauração de resina composta, empregando quatro tipos de tratamento na base do braquete. MÉTODOS: foram utilizados 48 discos de resina fotoativada (Filtek® Z250 incluídos em corpos de prova, divididos em quatro grupos, com 12 espécimes em cada grupo, de acordo com o tipo de tratamento realizado na base do braquete. Uma vez colados os braquetes, os corpos de prova foram submetidos à tensão de cisalhamento, realizado numa máquina universal de ensaios (MTS: 810 Material Test System calibrada com velocidade fixa de 0,5mm/min. Os valores obtidos foram registrados e comparados por meio de médias, utilizando-se testes estatísticos adequados (análise de Variância e, posteriormente, teste de Tukey. RESULTADOS E CONCLUSÕES: o condicionamento das superfícies dos braquetes cerâmicos com ácido hidrofluorídrico a 10% por 1 minuto

  2. Aseismic Test of Stationary Lead-acid Batteries and Brackets Based on Nuclear Safety Level%核安全级固定型铅酸蓄电池组及支架抗震试验研究

    Institute of Scientific and Technical Information of China (English)

    杨勇; 宫必宁; 张莹莹

    2011-01-01

    According to the aseismic test of stationary lead acid batteries and the brackets with nuclear safety level,the mathematical model is established to calculate the seismic response of the brackets by using finite element response spectrum method and equivalent static method. Compared with the experimental data, the results show that the response spectrum finite element method has better precision and reasonableness than the equivalent static method, which also has a conservative margin.%基于核安全级固定型铅酸蓄电池组及支架抗震试验,构建了相应数学分析模型,采用反应谱有限元法和等效静力法计算了支架地震响应,并与试验数据进行了对比.结果表明,反应谱有限元计算结果相对于等效静力计算结果相对精确、合理,且有一定保守裕度.

  3. Altered Passive Eruption Complicating Optimal Orthodontic Bracket Placement: A Case Report and Review of Literature

    Science.gov (United States)

    Chitra, Prasad

    2015-01-01

    An unusual case of altered passive eruption with gingival hyperpigmentation and a Class I malocclusion in a 12-year-old girl having no previous history of medication is presented. The patient reported with spacing in the upper arch, moderate crowding in the lower arch, anterior crossbite and excessive gingival tissue on the labial surfaces of teeth in both the arches. The inadequate crown lengths made placement of the orthodontic brackets difficult. Preadjusted orthodontic brackets have a very precise placement protocol which can affect tooth movement in all 3 planes of space if violated. The periodontal condition was diagnosed as altered passive eruption Type IA. Interdisciplinary treatment protocols including periodontal surgical and orthodontic procedures were used. The periodontal surgical procedures were carried out prior to orthodontic therapy and the results obtained were satisfactory. It is suggested that orthodontists should be aware of conditions like altered passive eruption and modalities of management. In most instances, orthodontic therapy is not hindered. PMID:26672498

  4. Effect of Four Methods of Surface Treatment on Shear Bond Strength of Orthodontic Brackets to Zirconium

    Directory of Open Access Journals (Sweden)

    Soghra Yassaei

    2015-10-01

    Full Text Available Objectives: Providing reliable attachment between bracket base and zirconia surface is a prerequisite for exertion of orthodontic force. The purpose of the present study was to eval- uate the effect of four zirconium surface treatment methods on shear bond strength (SBS of orthodontic brackets.Materials and Methods: One block of zirconium was trimmed into four zirconium sur- faces, which served as our four study groups and each had 18 metal brackets bonded to them. Once the glazed layer was removed, the first group was etched with 9.6% hydrofluoric acid (HF, and the other three groups were prepared by means of sandblasting and 1 W, and 2 W Er: YAG laser, respectively. After application of silane, central incisor brackets were bonded to the zirconium surfaces. The SBS values were measured by a Dartec testing ma- chine with a crosshead speed of 1 mm/min.Results: The highest SBS was achieved in the sandblasted group (7.81±1.02 MPa followed in a descending order by 2 W laser group (6.95±0.87 MPa, 1 W laser group (6.87±0.92MPa and HF acid etched group (5.84±0.78 MPa. The differences between the study groups, were statistically significant except between the laser groups (P < 0.05. Conclusion: In terms of higher bond strength and safety, sandblasting and Er: YAG laser irradiation with power output of 1 W and 2 W can be considered more appropriate alterna- tives to HF acid etching for zirconium surface treatment prior to bracket bonding.

  5. Impact of Orthodontic Brackets on the Intraoral Scan Data Accuracy

    Directory of Open Access Journals (Sweden)

    Ji-Man Park

    2016-01-01

    Full Text Available This study aims to compare the impact of buccal and lingual brackets on the accuracy of dental arch data acquired by 4 different digital intraoral scanners. Two pairs of dental casts, one with buccal brackets and the other with lingual brackets, were used. Digital measurements of the 3D images were compared to the actual measurements of the dental models, which were considered standard values. The horizontal measurements included intercanine widths and intermolar widths. The Mann–Whitney U test was performed for comparisons. iTero® and Trios® both showed high accuracy with relatively small maximum deviation of measurements. iTero showed a significantly higher accuracy in most of the arch width measurements on the buccal bracket model than on the lingual model (P<0.05. Zfx IntraScan® and E4D Dentist® produced maximum deviations of more than 2 mm from both the buccal and the lingual bracket models. After comparing the degree of distortion of the arch on the digital scans with actual measurements of the same models, iTero and Trios proved to be excellent in terms of trueness and precision. Nevertheless, digital intraoral scanners should be used more cautiously in arches with lingual brackets than in those with buccal brackets.

  6. Color stability of ceramic brackets immersed in potentially staining solutions

    Directory of Open Access Journals (Sweden)

    Bruna Coser Guignone

    2015-08-01

    Full Text Available OBJECTIVE: To assess the color stability of five types of ceramic brackets after immersion in potentially staining solutions.METHODS: Ninety brackets were divided into 5 groups (n = 18 according to brackets commercial brands and the solutions in which they were immersed (coffee, red wine, coke and artificial saliva. The brackets assessed were Transcend (3M/Unitek, Monrovia, CA, USA, Radiance (American Orthodontics, Sheboygan, WI, USA, Mystique (GAC International Inc., Bohemia, NY, USA and Luxi II (Rocky Mountain Orthodontics, Denver, CO, USA. Chromatic changes were analyzed with the aid of a reflectance spectrophotometer and by visual inspection at five specific time intervals. Assessment periods were as received from the manufacturer (T0, 24 hours (T1, 72 hours (T2, as well as 7 days (T3 and 14 days (T4 of immersion in the aforementioned solutions. Results were submitted to statistical analysis with ANOVA and Bonferroni correction, as well as to a multivariate profile analysis for independent and paired samples with significance level set at 5%.RESULTS: The duration of the immersion period influenced color alteration of all tested brackets, even though these changes could not always be visually observed. Different behaviors were observed for each immersion solution; however, brackets immersed in one solution progressed similarly despite minor variations.CONCLUSIONS: Staining became more intense over time and all brackets underwent color alterations when immersed in the aforementioned solutions.

  7. Collaborative learning in condition based maintenance

    NARCIS (Netherlands)

    Koochaki, J.; Ao, SI; Gelman, L; Hukins, DWL; Hunter, A; Korsunsky, AM

    2009-01-01

    In recent years, the importance of reliable and consistent production equipments has increased. As a result, companies are shifting their maintenance policy from preventive maintenance towards Condition Based Maintenance (CBM). Despite the growing trend in this area and success stories of CBM implem

  8. Survival analysis with clustered observations of orthodontic brackets.

    Science.gov (United States)

    Petracci, Elisabetta; Farella, Mauro; Galeone, Carlotta; Albano, Alessandra; Ferraroni, Monica; Decarli, Adriano

    2009-12-10

    Failures in the bonding of dental bracket are a big concern for orthodontists. Clinical experience suggests that some patients are more prone than others to experience failures. Therefore, it can be expected that in statistical analysis of orthodontic bracket failures, the usual assumption of independence between the observations is violated. An approach to overcome this problem is to apply the frailty model, in which the association between failure times is modelled with a random-effect term (i.e. frailty). We postulated that brackets of the same subject share the same frailty, that is, a latent common group effect, due to some unknown or unobserved covariates.The aim of this study was to investigate possible risk factors related to bracket failure using Cox proportional hazards model with a shared frailty term and to compare the results with those obtained using a basic Cox proportional hazards model.Survival data for 1677 brackets were obtained from a cohort of 54 females (mean age +/- SD: 13.3+/-4.8 yrs) and 46 males (mean age +/-SD: 13.1+/-3.8 yrs) over a eight-year period. Age, gender, vertical craniofacial morphology and anatomical location of brackets were entered into Cox models as covariates. The findings indicated that bracket failure was significantly affected by tooth position within the dental arch, with the highest failure risk in maxillary posterior region. Age, gender and vertical craniofacial morphology did not affect bracket failure. A Cox proportional hazards model with a shared frailty term represents a useful approach for modelling orthodontic bracket failures. Copyright (c) 2009 John Wiley & Sons, Ltd.

  9. A influência da variação da curvatura da base do braquete em uma união ortodôntica submetida a diferentes cargas, através do método dos elementos finitos The influence of the variation of the bracket base curvature in a bonded orthodontic attachment submitted by different load cases using the finite element method

    Directory of Open Access Journals (Sweden)

    Cláudio Pereira Viana

    2005-06-01

    Full Text Available Este trabalho procurou avaliar, através do Método dos Elementos Finitos, a resistência ao deslocamento de quatro diferentes bases de braquetes "straight-wire" (Morelli, Unitek, A-Company e Abzil-Lancer na aplicação de forças de torção e cisalhamento, correlacionando essa resistência à melhor adaptação das bases à superfície vestibular dentária. As curvaturas das bases de braquetes utilizados no presente estudo foram descritas em um estudo prévio, enquanto o contorno dentário foi obtido a partir do escaneamento e cálculo da curvatura média vestibular do canino inferior de uma amostra de 30 indivíduos brasileiros. Empregou-se a análise tridimensional por Elementos Finitos da interface esmalte vestibular/cimento/base do braquete para cada marca testada. Forças de 1N, promovendo deslocamento lateral e torção, foram aplicadas no centro da base do braquete e observou-se a distribuição desses esforços sobre os modelos assim como as tensões normais e de cisalhamento geradas. Os resultados mostraram que a base que melhor se adaptou à superfície vestibular construída foi a da marca Unitek, seguida pela marca A-Company, Abzil-Lancer e Morelli. As deformações sofridas pelos braquetes foram inversamente proporcionais à adaptação à superfície dentária. Os maiores picos de tensão localizaram-se nas proximidades do ponto de aplicação da força. A interface adesivo/esmalte foi mais sujeita à falha na adesão que a interface braquete/adesivo. A força de cisalhamento demonstrou ser mais provável de causar falha na adesão quando comparada à força de torção.The objective of this study was to evaluate the adaptability of the four straight-wire brackets bases (Morelli, Unitek, A-Company and Abzil-Lancer to facial surface of a lower canine. The lower canine facial curvature data to be used in the three-dimensional finite element model were established by 30 Brazilian adult individuals and the brackets bases curvature

  10. Assessment of surface friction of self-ligating brackets under conditions of angulated traction Avaliação da fricção superficial apresentada por braquetes autoligáveis em condições de tracionamento sob angulação

    Directory of Open Access Journals (Sweden)

    Roberta Buzzoni

    2012-08-01

    Full Text Available OBJECTIVE: The aim of this study was to assess resistance to sliding of stainless steel passive self-ligating brackets with 0° and 2.5° angulations and to compare them to active self-ligating brackets at zero angulation. The hypothesis to be tested was that passive self-ligating brackets produce lower frictional forces than active self-ligating brackets. METHODS: Twenty five 0.022 x 0.028-in slot maxillary canine brackets were divided into 5 groups of 5 brackets: Damon SL II (Ormco, CA, USA self-ligating bracket and Gemini (3M/Unitek, CA, USA conventional bracket with angulation of 0 and 2.5° and a group of Speed 2 (American Orthodontics, WI, USA active clip self-ligating system with zero angulation. Twenty five segments of stainless steel 0.020-in archwire (TP Orthodontics, IN, USA were tested and each bracket/wire interface was evaluated at 4 successive points during sliding. Overall, 100 frictional values were analyzed by parametric analysis of variance and Bonferroni tests. RESULTS AND CONCLUSION: Frictional tests were performed with an Emic DL 10000 testing machine (Emic, Brazil with a load cell of one kilogram. Passive self-ligating brackets produced lower frictional forces than active self-ligating brackets (p OBJETIVO: avaliar a fricção apresentada por braquetes autoligáveis de aço inoxidável com sistema passivo de tampa deslizante sob angulação de 0 grau e 2,5 graus, e comparar o comportamento desse grupo sob angulação nula com o de um grupo de braquetes autoligáveis com sistema ativo de tampa resiliente. MÉTODOS: foram utilizados 25 braquetes de caninos superiores, divididos em 5 grupos - braquetes autoligáveis passivos Damon SL II sob angulação de 0 grau e de 2,5 graus; braquetes convencionais Gemini amarrados com ligaduras elásticas sob as mesmas angulações; e um grupo formado pelo sistema ativo Time 2, sob angulação nula. A hipótese a ser testada é se artefatos autoligáveis com sistema de tampa passiva s

  11. Effects of enamel sealing on shear bond strength and the adhesive remnant index : Study of three fluoride-releasing adhesives in combination with metal and ceramic brackets.

    Science.gov (United States)

    Hofmann, Elisabeth; Elsner, Laura; Hirschfelder, Ursula; Ebert, Thomas; Hanke, Sebastian

    2017-01-01

    Selected combinations of materials were used to create tooth-adhesive-bracket complexes to evaluate shear bond strength (SBS) and the adhesive remnant index (ARI) with regard to enamel sealing. Four adhesive systems also appropriate for use as enamel sealants were combined with four bracket types, resulting in 16 adhesive-bracket combinations, each of which was tested on 15 permanent bovine incisors. Sealant-adhesives included two recently introduced fluoride-releasing systems (Riva bond LC(®) and go!(®)), one established primer (Opal(®) Seal™), and one commonly used adhesive as control (Transbond™ XT). Brackets included two metal (discovery(®) by Dentaurum and Sprint(®)) and two ceramic (discovery(®) pearl and GLAM(®)) systems. After embedding the bovine teeth, bonding the brackets to their surface, and storing the resultant samples as per DIN 13990-2 with modifications, an SBS test was performed by applying the shear force directly at the bracket base in an incisocervical direction. Then the ARI scores were determined. Discovery(®) + Transbond™ XT yielded the highest (47.2 MPa) and GLAM(®) + go!(®) the lowest (17.0 MPa) mean SBS values. Significant differences (p < 0.0001) were found between metal and ceramic brackets of the same manufacturers (Dentaurum and Forestadent). Our ratings of the failure modes upon debonding predominantly yielded ARI 0 or 1. The high SBS values and low ARI scores observed with discovery(®) + Transbond XT™ were reflected in a high rate of enamel fracture, which occurred on 11 of the 15 tooth specimens in this group. All sealant-bracket combinations were found to yield levels of SBS adequate for clinical application. SBS values and ARI scores varied significantly depending on which sealant-brackets were used.

  12. Effect of fluoridated casein phospopeptide-amorphous-calcium phosphate complex, chlorhexidine fluoride mouthwash on shear bond strength of orthodontic brackets: A comparative in vitro study

    Directory of Open Access Journals (Sweden)

    C A Abdul Shahariyar

    2016-01-01

    Full Text Available Objective: The aim of the current study was to determine the effects of casein phosphopeptide amorphous calcium-phosphate (CPP-ACP complex, chlorhexidine fluoride mouthwash on shear bond strengths (SBSs of orthodontic brackets. Materials and Methods: About sixty extracted healthy human premolar teeth with intact buccal enamel were divided into two equal groups to which brackets were bonded using self-etching primers (SEPs and conventional means respectively. These were further equally divided into three subgroups - (1 control (2 CPP-ACP (3 chlorhexidine fluoride mouthwash. The SBSs were then measured using a universal testing machine. Results: SBS of the conventional group was significantly higher than the self-etching group. The intragroup differences were statistically insignificant. Conclusion: CPP-ACP, chlorhexidine fluoride mouthwash did not adversely affect SBS of orthodontic brackets irrespective of the method of conditioning. Brackets bonded with conventional technique showed greater bond strengths as compared to those bonded with SEP.

  13. Photoelastic analysis of stress generated by wires when conventional and self-ligating brackets are used: A pilot study

    Directory of Open Access Journals (Sweden)

    Guilherme Caiado Sobral

    2014-10-01

    Full Text Available OBJECTIVE: By means of a photoelastic model, this study analyzed the stress caused on conventional and self-ligating brackets with expanded arch wires. METHOD: Standard brackets were adhered to artificial teeth and a photoelastic model was prepared using the Interlandi 19/12 diagram as base. Successive activations were made with 0.014-in and 0.018-in rounded cross section Nickel-Titanium wires (NiTi and 0.019 x 0.025-in rectangular stainless steel wires all of which made on 22/14 Interlandi diagram. The model was observed on a plane polariscope - in a dark field microscope configuration - and photographed at each exchange of wire. Then, they were replaced by self-ligating brackets and the process was repeated. Analysis was qualitative and observed stress location and pattern on both models analyzed. CONCLUSIONS: Results identified greater stress on the region of the apex of premolars in both analyzed models. Upon comparing the stress between models, a greater amount of stress was found in the model with conventional brackets in all of its wires. Therefore, the present pilot study revealed that alignment of wires in self-ligating brackets produced lower stress in periodontal tissues in expansive mechanics.

  14. Platform Based Design for Automotive Sensor Conditioning

    CERN Document Server

    Fanucci, L; Iozzi, F; Marino, C; Rocchi, A

    2011-01-01

    In this paper a general architecture suitable to interface several kinds of sensors for automotive applications is presented. A platform based design approach is pursued to improve system performance while minimizing time-to-market.. The platform is composed by an analog front-end and a digital section. The latter is based on a microcontroller core (8051 IP by Oregano) plus a set of dedicated hardware dedicated to the complex signal processing required for sensor conditioning. The microcontroller handles also the communication with external devices (as a PC) for data output and fast prototyping. A case study is presented concerning the conditioning of a Gyro yaw rate sensor for automotive applications. Measured performance results outperform current state-of-the-art commercial devices.

  15. Time-dependent constrained Hamiltonian systems and Dirac brackets

    Energy Technology Data Exchange (ETDEWEB)

    Leon, Manuel de [Instituto de Matematicas y Fisica Fundamental, Consejo Superior de Investigaciones Cientificas, Madrid (Spain); Marrero, Juan C. [Departamento de Matematica Fundamental, Facultad de Matematicas, Universidad de La Laguna, La Laguna, Tenerife, Canary Islands (Spain); Martin de Diego, David [Departamento de Economia Aplicada Cuantitativa, Facultad de Ciencias Economicas y Empresariales, UNED, Madrid (Spain)

    1996-11-07

    In this paper the canonical Dirac formalism for time-dependent constrained Hamiltonian systems is globalized. A time-dependent Dirac bracket which reduces to the usual one for time-independent systems is introduced. (author)

  16. On the optimality of double-bracket flows

    Directory of Open Access Journals (Sweden)

    Anthony M. Bloch

    2004-01-01

    Full Text Available We analyze the optimality of the stable fixed point of the double-bracket equations. We introduce different types of optimality and prove local and global optimality results with respect to the Schatten p-norms.

  17. Ligand "Brackets" for Ga-Ga Bond.

    Science.gov (United States)

    Fedushkin, Igor L; Skatova, Alexandra A; Dodonov, Vladimir A; Yang, Xiao-Juan; Chudakova, Valentina A; Piskunov, Alexander V; Demeshko, Serhiy; Baranov, Evgeny V

    2016-09-06

    The reactivity of digallane (dpp-Bian)Ga-Ga(dpp-Bian) (1) (dpp-Bian = 1,2-bis[(2,6-diisopropylphenyl)imino]acenaphthene) toward acenaphthenequinone (AcQ), sulfur dioxide, and azobenzene was investigated. The reaction of 1 with AcQ in 1:1 molar ratio proceeds via two-electron reduction of AcQ to give (dpp-Bian)Ga(μ2-AcQ)Ga(dpp-Bian) (2), in which diolate [AcQ](2-) acts as "bracket" for the Ga-Ga bond. The interaction of 1 with AcQ in 1:2 molar ratio proceeds with an oxidation of the both dpp-Bian ligands as well as of the Ga-Ga bond to give (dpp-Bian)Ga(μ2-AcQ)2Ga(dpp-Bian) (3). At 330 K in toluene complex 2 decomposes to give compounds 3 and 1. The reaction of complex 2 with atmospheric oxygen results in oxidation of a Ga-Ga bond and affords (dpp-Bian)Ga(μ2-AcQ)(μ2-O)Ga(dpp-Bian) (4). The reaction of digallane 1 with SO2 produces, depending on the ratio (1:2 or 1:4), dithionites (dpp-Bian)Ga(μ2-O2S-SO2)Ga(dpp-Bian) (5) and (dpp-Bian)Ga(μ2-O2S-SO2)2Ga(dpp-Bian) (6). In compound 5 the Ga-Ga bond is preserved and supported by dithionite dianionic bracket. In compound 6 the gallium centers are bridged by two dithionite ligands. Both 5 and 6 consist of dpp-Bian radical anionic ligands. Four-electron reduction of azobenzene with 1 mol equiv of digallane 1 leads to complex (dpp-Bian)Ga(μ2-NPh)2Ga(dpp-Bian) (7). Paramagnetic compounds 2-7 were characterized by electron spin resonance spectroscopy, and their molecular structures were established by single-crystal X-ray analysis. Magnetic behavior of compounds 2, 5, and 6 was investigated by superconducting quantum interference device technique in the range of 2-295 K.

  18. Nickel and chromium ion release from stainless steel bracket on immersion various types of mouthwashes

    Science.gov (United States)

    Mihardjanti, M.; Ismah, N.; Purwanegara, M. K.

    2017-08-01

    The stainless steel bracket is widely used in orthodontics because of its mechanical properties, strength, and good biocompatibility. However, under certain conditions, it can be susceptible to corrosion. Studies have reported that the release of nickel and chromium ions because of corrosion can cause allergic reactions in some individuals and are mutagenic. The condition of the oral environment can lead to corrosion, and one factor that can alter the oral environment is mouthwash. The aim of this study was to measure the nickel and chromium ions released from stainless steel brackets when immersed in mouthwash and aquadest. The objects consisted of four groups of 17 maxillary premolar brackets with .022 slots. Each group was immersed in a different mouthwash and aquadest and incubated at 37 °C for 30 days. After 30 days of immersion, the released ions were measured using the ICP-MS (Inductively Coupled Plasma-Mass Spectrometer). For statistical analysis, both the Kruskal-Wallis and Mann-Whitney tests were used. The results showed differences among the four groups in the nickel ions released (p < 0.05) and the chromium ions released (p < 0.5). In conclusion, the ions released as a result of mouthwash immersion have a small value that is below the limit of daily intake recommended by the World Health Organization.

  19. Corrosion behavior of self-ligating and conventional metal brackets

    Directory of Open Access Journals (Sweden)

    Lúcio Henrique Esmeraldo Gurgel Maia

    2014-04-01

    Full Text Available Objective: To test the null hypothesis that the aging process in self-ligating brackets is not higher than in conventional brackets. Methods: Twenty-five conventional (GN-3M/Unitek; GE-GAC; VE-Aditek and 25 self-ligating (SCs-3M/Unitek; INs-GAC; ECs-Aditek metal brackets from three manufacturers (n = 150 were submitted to aging process in 0.9% NaCl solution at a constant temperature of 37 ± 1ºC for 21 days. The content of nickel, chromium and iron ions in the solution collected at intervals of 7, 14 and 21 days was quantified by atomic absorption spectrophotometry. After the aging process, the brackets were analyzed by scanning electron microscopy (SEM under 22X and 1,000X magnifications. Results: Comparison of metal release in self-ligating and conventional brackets from the same manufacturer proved that the SCs group released more nickel (p < 0.05 than the GN group after 7 and 14 days, but less chromium (p < 0.05 after 14 days and less iron (p < 0.05 at the three experimental time intervals. The INs group released less iron (p < 0.05 than the GE group after 7 days and less nickel, chromium and iron (p < 0.05 after 14 and 21 days. The ECs group released more nickel, chromium and iron (p < 0.05 than the VE group after 14 days, but released less nickel and chromium (p < 0.05 after 7 days and less chromium and iron (p < 0.05 after 21 days. The SEM analysis revealed alterations on surface topography of conventional and self-ligating brackets. Conclusions: The aging process in self-ligating brackets was not greater than in conventional brackets from the same manufacturer. The null hypothesis was accepted.

  20. [Hardened anodized aluminum as a replacement material for bracket manufacture].

    Science.gov (United States)

    Fischer-Brandies, H; Bönhoff, M

    1994-12-01

    Attention has been repeatedly drawn to the problem of corrosion and the risk of allergic reaction to nickel resulting from the use of stainless steel brackets. In the search for a suitable alternative, manufacturers have turned to thin coating technology using hardened anodized aluminium. Applying resistance to corrosion and abrasion as the criteria to be met, they have selected aluminium alloy type 6082 as the material of choice. Purpose of this study is to examine the physical suitability of this material. Using the above noted alloy, 60 prototype brackets were made with a hardened anodized surface. They were then subjected to the following 3 stress tests: first an abrasion test using a tooth polishing machine, second, a deformation test using a device designed to simulate torque movement, and, third, a corrosion test. The effects on the brackets resulting from the three types of stress were evaluated by light microscopy. A quantitative analysis of the corrosion test was performed by ICP spectrometry. The control group consisted of conventional stainless steel brackets. The light microscopic analysis revealed no evidence of surface damage or signs of deformation in the prototype brackets. The steel brackets, on the other hand, showed clear signs of wear and corrosion. The quantitative analysis of the corrosion solution revealed metallic ion wear of 1.75 ng x mm-2 x h-1 for the prototypes subjected to abrasion. The steel brackets showed at a factor of around 104.6 metallic ion wear of 183 ng x mm-2 x h-1. In addition to this, no Ni ions were found in the corrosion solution of the prototype brackets.(ABSTRACT TRUNCATED AT 250 WORDS)

  1. In-vitro evaluation of various treatments to prevent demineralization next to orthodontic brackets.

    Science.gov (United States)

    Behnan, Scott M; Arruda, Airton O; González-Cabezas, Carlos; Sohn, Woosung; Peters, Mathilde C

    2010-12-01

    One common negative side effect of orthodontic treatment with fixed appliances is the development of incipient caries lesions around brackets, particularly in patients with poor oral hygiene. Bio-available minerals from cement containing amorphous calcium phosphate (ACP) might facilitate remineralization and inhibit lesion development. Our objective was to compare the potential of ACP-containing resin cement, fluoride varnish, resin sealer, and MI Paste (GC America, Alsip, Ill) under similar in-vitro conditions to prevent incipient caries lesions next to brackets on teeth. One hundred extracted premolars were randomly allocated to 5 groups (n = 20). Brackets were bonded with ACP cement (Aegis-Ortho, Bosworth, Skokie, Ill), resin (Transbond XT [3M Unitek, Monrovia, Calif], control), or resin followed by application of fluoride varnish (Vanish, 3M, St Paul, Minn), resin sealer (Pro-seal, Reliance Orthodontic Products, Itasca, Ill), or casein phosphopeptide-ACP paste (MI Paste). All groups were cycled for 15 days in demineralization solution for 8 hours a day, rinsed, placed in artificial saliva (30 minutes), brushed, and stored overnight in artificial saliva. The extent of demineralization in each group was assessed by using quantitative light-induced fluorescence and confocal laser scanning microscopy. Only the Pro-seal and Vanish groups showed significantly smaller lesions than the controls (Kruskal-Wallis test, P Vanish; Aegis-Ortho, MI Paste, and the controls were not different from each other. Both light-cured filled resin (Pro-seal) and fluoride varnish (Vanish) might prevent enamel demineralization next to orthodontic brackets exposed to cariogenic conditions, but the observed positive effects of Aegis-Ortho and MI Paste were not significant. Copyright © 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  2. Reconstructions of the axial muscle insertions in the occipital region of dinosaurs: evaluations of past hypotheses on marginocephalia and tyrannosauridae using the extant phylogenetic bracket approach.

    Science.gov (United States)

    Tsuihiji, Takanobu

    2010-08-01

    The insertions of the cervical axial musculature on the occiput in marginocephalian and tyrannosaurid dinosaurs have been reconstructed in several studies with a view to their functional implications. Most of the past reconstructions on marginocephalians, however, relied on the anatomy of just one clade of reptiles, Lepidosauria, and lack phylogenetic justification. In this study, these past reconstructions were evaluated using the Extant Phylogenetic Bracket approach based on the anatomy of various extant diapsids. Many muscle insertions reconstructed in this study were substantially different from those in the past studies, demonstrating the importance of phylogenetically justified inferences based on the conditions of Aves and Crocodylia for reconstructing the anatomy of non-avian dinosaurs. The present reconstructions show that axial muscle insertions were generally enlarged in derived marginocephalians, apparently correlated with expansion of their parietosquamosal shelf/frill. Several muscle insertions on the occiput in tyrannosaurids reconstructed in this study using the Extant Phylogenetic Bracket approach were also rather different from recent reconstructions based on the same, phylogenetic and parsimony-based method. Such differences are mainly due to differences in initial identifications of muscle insertion areas or different hypotheses on muscle homologies in extant diapsids. This result emphasizes the importance of accurate and detailed observations on the anatomy of extant animals as the basis for paleobiological inferences such as anatomical reconstructions and functional analyses.

  3. Influence of ceramic surface treatment on shear bond strength of ceramic brackets

    Directory of Open Access Journals (Sweden)

    Tatiana Fernandes Ramos

    2012-01-01

    Full Text Available Objective: To compare four different surface treatment methods and determine which produces adequate bond strength between ceramic brackets and facets of porcelain (feldspathic, and evaluate the Adhesive Remnant Index (ARI scores. Materials and Methods: Ten facets of porcelain specimens with glazed surfaces were used for each group. The specimens were randomly assigned to one of the following treatment conditions of the porcelain surface: (1 no surface treatment (control group, (2 fine diamond bur + orthophosphoric acid gel 37%, (3 hydrofluoric acid (HFL 10%, and (4 HFL 10% + silane. Ceramic brackets were bonded with the adhesive cement Transbond XT. The shear bond strength values were measured on a universal testing machine at a crosshead speed of 0.5 mm/min. Results: There was a significant difference (P<0.05 between the control group and all other groups. There was no significant difference (P<0.05 between treated porcelain surface with diamond bur + orthophosphoric acid gel 37% (4.8 MPa and HFL 10% (6.1 MPa, but the group treated with HFL 10% had clinically acceptable bond strength values. The group treated with HFL 10% + silane (17.5 MPa resulted in a statistically significant higher tensile bond strength (P<0.05. In group 4, 20% of the porcelain facets displayed damage. Conclusion: Etching of the surface with HFL increased the bond strength values. Silane application was recommended to bond a ceramic bracket to the porcelain surface in order to achieve bond strengths that are clinically acceptable.

  4. Structural integrity assessment of HANARO in-chimney bracket structures

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Soo; Lee, J. H.; Cho, Y. G.; Lee, J. H. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-09-01

    In HANARO are there provided three hexagonal irradiation holes (CT, IR1 and IR2) in the central region of the core while four circular irradiation holes (OR3 {approx} OR6) in the outer core. There exist two types of irradiation facilities: uninstrumented or instrumented. The uninstrumented irradiation facility is little influenced by the coolant flow. But the dynamic behavior by the flow-induced vibration (FIV) and seismic loads is expected to largely occur in case of the instrumented test facility due to the long guide tube to protect the instrumentation cables. To suppress this dynamic behavior, the in-chimney bracket was designed. It is believed that the irradiation test can be successfully conducted since this bracket can reduce the FIV and dynamic response to seismic load as well. The installation position of the bracket is 60 cm below from the top of the chimney, i.e., thermosiphoning opening position. For evaluating the structural integrity on the in-chimney bracket and related reactor structures, ANSYS finite element analysis model is developed and the dynamic characteristics are analyzed. The seismic response analyses of in-chimney bracket and related reactor structures of HANARO under the design earthquake response spectrum loads of OBE(0.1g) and SSE(0.2g) are performed. The analysis result shows that the stress values in main points of reactor structures and in-chimney bracket for the seismic loads are also within the SAME Code limits. Therefore any damage on structural integrity is not expected when an in-chimney bracket is installed in the upper part of the reactor chimney. 12 refs., 32 figs., 21 tabs. (Author)

  5. Comparative analysis of slot dimension in lingual bracket systems

    Directory of Open Access Journals (Sweden)

    Dittmer Marc P

    2009-12-01

    Full Text Available Abstract Background Orthodontic treatment with fixed appliances requires - among others - the correct clinical expression of torque, which depends on the precise fitting of archwire and slot. Especially in the lingual technique torque problems become clinically more evident than in labial appliances also with respect to the vertical alignment of teeth due to different distances from the center of resistance. The purpose of the present study was to compare the preciseness of slot dimensions of different lingual bracket systems. Methods Three lingual bracket systems were included in the study (7th Generation and STb, Ormco, Glendora, CA, USA; Incognito, TOP-Service/3 M Unitek, Monrovia, CA, USA. Non destructive analysis of vertical slot dimensions was performed using precision pin gauges (Azurea, Belprahon, Switzerland that were tapered in increments of 0.002 mm (0.00008 inch. The sizes of 240 incisor and canine brackets were measured per system (total: 720. Data were compared using one-way ANOVA. A p-value Results Average slot dimensions were 0.467 mm ± 0.007 mm (0.0184 inch ± 0.0003 inch for the 7th Generation bracket system, 0.466 mm ± 0.004 mm (0.0183 inch ± 0.0001 inch for the STb bracket system and 0.459 mm ± 0.004 mm (0.0181 inch ± 0.0001 inch for the Incognito bracket system. Differences between systems were statistically significant (p Conclusions The analyzed bracket systems for lingual treatment exhibited significant differences in slot dimension that will clinically result in torque play. These aspects must be considered in lingual orthodontic treatment.

  6. Microleakage under orthodontic brackets bonded with different adhesive systems.

    Science.gov (United States)

    Alkis, Huseyin; Turkkahraman, Hakan; Adanir, Necdet

    2015-01-01

    This in vitro study aimed to compare the microleakage of orthodontic brackets between enamel-adhesive and adhesive-bracket interfaces at the occlusal and gingival margins bonded with different adhesive systems. A total of 144 human maxillary premolar teeth extracted for orthodontic reasons was randomly divided into four groups. Each group was then further divided into three sub-groups. Three total-etching bonding systems (Transbond XT, Greengloo and Kurasper F), three one-step self-etching bonding systems (Transbond Plus SEP, Bond Force and Clearfil S3), three two-step self-etching bonding systems (Clearfil SE Bond, Clearfil Protectbond and Clearfil Liner Bond), and three self-adhesive resin cements (Maxcem Elite, Relyx U 100 and Clearfil SA Cement) were used to bond the brackets to the teeth. After bonding, all teeth were sealed with nail varnish and stained with 0.5% basic fuchsine for 24 h. All samples were sectioned and examined under a stereomicroscope to score for microleakage at the adhesive-enamel and adhesive-bracket interfaces from both occlusal and gingival margins. Statistical analyses were performed with Kruskal-Wallis and Wilcoxon signed-rank tests. The results indicate no statistically significant differences between the microleakage scores of the adhesives; microleakage was detected in all groups. Comparison of the average values of the microleakage scores in the enamel-adhesive and adhesive-bracket interfaces indicated statistically significant differences (P adhesive interface than at the bracket-adhesive interface. All of the brackets exhibited some amount of microleakage. This result means that microleakage does not depend on the type of adhesive used.

  7. Longitudinal monitoring of demineralization peripheral to orthodontic brackets using cross polarization optical coherence tomography.

    Science.gov (United States)

    Nee, Alexander; Chan, Kenneth; Kang, Hobin; Staninec, Michal; Darling, Cynthia L; Fried, Daniel

    2014-05-01

    The aim of this study was to test the hypothesis that cross-polarization optical coherence tomography (CP-OCT) can be used to longitudinally monitor demineralization peripheral to orthodontic brackets in an extended clinical study. A high-speed CP-OCT system was used to acquire 3D volumetric images of the area at the base of orthodontic brackets over a period of 12 months after placement. The reflectivity was measured at 3-month intervals for 12 months to determine if there was increased demineralization. Two teeth were monitored on 20 test subjects and the brackets were bonded using two types of adhesives. This was a randomized controlled clinical study with a split mouth design such that each subject served as his or her own control. On one side, the control premolar was bonded with a bonding agent (Adper Scotchbond from 3M ESPE, St. Paul, MN) and composite (Transbond XT from 3M Unitek, Monrovia, CA) that lacked fluoride. On the other side, the experimental premolar was bonded with a fluoride releasing glass ionomer cement (GC Fuji Ortho LC from GC America, Alsip, IL). There was a small but significant increase in the calculated lesion depth and integrated reflectivity over that depth (ΔR) for both adhesive types (pfluoride releasing glass ionomer cement and the conventional composite. CP-OCT was able to measure a significant increase in demineralization (p<0.0001) at the base of orthodontic brackets over a period of 12 months. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Formulation of singular theories in a partial Hamiltonian formalism using a new bracket and multi-time dynamics

    Science.gov (United States)

    Duplij, Steven

    2015-09-01

    A formulation of singular classical theories (determined by degenerate Lagrangians) without constraints is presented. A partial Hamiltonian formalism in the phase space having an initially arbitrary number of momenta (which can be smaller than the number of velocities) is proposed. The equations of motion become first-order differential equations, and they coincide with those of multi-time dynamics, if a certain condition is imposed. In a singular theory, this condition is fulfilled in the case of the coincidence of the number of generalized momenta with the rank of the Hessian matrix. The noncanonical generalized velocities satisfy a system of linear algebraic equations, which allows an appropriate classification of singular theories (gauge and nongauge). A new antisymmetric bracket (similar to the Poisson bracket) is introduced, which describes the time evolution of physical quantities in a singular theory. The origin of constraints is shown to be a consequence of the (unneeded in our formulation) extension of the phase space, when the new bracket transforms into the Dirac bracket. Quantization is briefly discussed.

  9. 基于 CAE 支架的浇注系统与冷却系统的优化设计%CAE-based optimal design of feed system and cooling system in mould for bracket

    Institute of Scientific and Technical Information of China (English)

    谢金林; 盛希龙; 王小新

    2014-01-01

    CAE analysis was made to accurately predict the distribution of melting line of a coffee machine bracket formed in a mould with different feed system design in order to prevent the appearance of melting line on the high gloss surface of the product. Through CAE verification analysis on the mould cooling system, the heat collector zone was found out and optimized to meet the requirements for the product quality and production cycle.%以咖啡机支架为研究对象,通过CAE分析,准确预测了不同浇注系统的熔接痕分布情况,避免熔接痕在塑件的高亮外观面上产生,通过对模具冷却系统的CAE验证分析,发现了塑件的集热区域,并对冷却系统进行优化以满足塑件质量和生产周期的要求。

  10. Lightweight Design of Balancing Suspension Bracket Based on Casting Defects and Structure Strength CAE%基于铸造缺陷和结构强度CAE的平衡悬架支架轻量化设计

    Institute of Scientific and Technical Information of China (English)

    张建振; 吴晓涛; 刘兆英; 常连霞; 朱明

    2014-01-01

    以节能减排为目的,以平衡悬架支架为研究对象进行轻量化设计。运用面向制造与装配的方法,借助铸造模拟MAGMA和结构优化及分析工具(OPTISTRUCT、ABAQUS)进行设计,使产品质量减轻40%,安全系数提高25%,成本降低5%。经台架试验验证了该轻量化方法的可行性,同时产品质量得到改善,开发周期也相应缩短。%For the purpose of energy saving and emission reduction, lightweight design is carried out for balanced suspension bracket. Using the method named DFMA ( Design for Manufacturing and Assembly), with the aid of casting simulation tool MAGMA, structure optimization tool OPTISTRUCT and topology optimization tool ABAQUS, the final product is lightened by 40%, safety factor of which is increased by 25%, and cost is reduced by 5%. Data from bench test of proves feasibility of the lightweight design plan, meanwhile the product quality is improved and development time is shortened.

  11. Experience with the COMPASS Conditions Data Base

    Institute of Scientific and Technical Information of China (English)

    TakeakiToeda; MassimoLamanna; 等

    2001-01-01

    The COMPASS experiment at CERN is starting data taking in summer 2001,The COMPASS off-line framework(CORAL)will use the CERN Conditions Data Base(CDB)to handle time dependent quantities like calibration constants and data from the slow control system.We describe the use of the CDB within CORAL and the fullscale performance tests on the COMPASS Computing Farm(CCF),The CDB has been interfaced to the SCADA PVSS slow control system.To continuously transfer all the data to the CDB and make them available to the users,We describe this interface,a feasibility study performed using mock data and we predict the expected performance.

  12. Ceramic bracket debonding with Tm:fiber laser

    Science.gov (United States)

    Demirkan, İrem; Sarp, Ayşe Sena Kabaş; Gülsoy, Murat

    2016-06-01

    Lasers have the potential for reducing the required debonding force and can prevent the mechanical damage given to the enamel surface as a result of conventional debonding procedure. However, excessive thermal effects limit the use of lasers for debonding purposes. The aim of this study was to investigate the optimal parameters of 1940-nm Tm:fiber laser for debonding ceramic brackets. Pulling force and intrapulpal temperature measurements were done during laser irradiation simultaneously. A laser beam was delivered in two different modes: scanning the fiber tip on the bracket surface with a Z shape movement or direct application of the fiber tip at one point in the center of the bracket. Results showed that debonding force could be decreased significantly compared to the control samples, in which brackets were debonded by only mechanical force. Intrapulpal temperature was kept equal or under the 5.5°C threshold value of probable thermal damage to pulp. Scanning was found to have no extra contribution to the process. It was concluded that using 1940-nm Tm:fiber laser would facilitate the debonding of ceramic brackets and can be proposed as a promising debonding tool with all the advantageous aspects of fiber lasers.

  13. HOTB: High precision parallel code for calculation of four-particle harmonic oscillator transformation brackets

    Science.gov (United States)

    Stepšys, A.; Mickevicius, S.; Germanas, D.; Kalinauskas, R. K.

    2014-11-01

    effective way, which allows us to calculate matrix of the brackets up to a few hundred times more rapidly and more accurate than in a previous version. Solution method: Using external parallelization libraries and mutable precision we created a pack of numerical codes based on the methods of compact expressions of the three and four-particle harmonics oscillator brackets 3HOB, 4HOB, presented in [3]. Restrictions: For double precision version calculations can be done up to harmonic oscillator (HO) energy quanta e=28. For quadruple precision mantissa is equal to approximately 34 decimal digits, therefore calculations can be done up to HO energy quanta to e=52. Running time: The running time depends on the harmonic oscillator energy quanta, cluster size and the precision of intermediate calculations. More information on Table 1 for 3HOB and Table 2 for 4HOB. Reasons for a new version: The new program version expands the limits of harmonic oscillator energy quanta and gives shorter calculation time. Extend the limits of calculation of HOB First version was able to produce harmonic oscillator transformation brackets for three and four particles if E≤HO energy quanta. With this version of our program, if quadruple or arbitrary precision functions are being used, it is possible to calculate three and four particle harmonic oscillator transformation brackets for greater values of energy and momenta, while sustaining tolerable margin of error. Calculation time As the code of previous version of program was redone using parallelism paradigma, it is now possible to reduce the calculation time of transformation matrices significantly, depending on the size of computing cluster, as the dimensions of matrices are growing very rapidly according to the energy and momenta values. subroutinematrix_4HOB_dimensionCalculates the dimension of 4HOB matrix. subroutinematrix_3HOB_dimensionCalculates the dimension of 3HOB matrix, subroutinematrix_3HOBCalculates the global state array which is

  14. Canonical form of Nambu–Poisson bracket: A pedestrian approach

    Indian Academy of Sciences (India)

    S K Soni; Swami Nandan

    2011-12-01

    In the seventies, Nambu (Phys. Rev. D7, 2405 (1973)) proposed a new approach to classical dynamics based on an -dimensional Nambu–Poisson (NP) manifold replacing the primitive even-dimensional Poisson manifold and on –1 Hamiltonians in place of a single Hamiltonian. This approach has had many promoters including Bayen and Flato (Phys. Rev. D11, 3049 (1975)), Mukunda and Sudarshan (Phys. Rev. D13, 2846 (1976)), and Takhtajan (Comm. Math. Phys. 160, 295 (1994)) among others. While Nambu had originally considered = 3, the illustration of his ideas for = 4 and 6 was given by Chatterjee (Lett. Math. Phys. 36, 117 (1996)) who observed that the classical description of dynamical systems having dynamical symmetries is described elegantly by Nambu’s formalism of mechanics. However, his considerations do not quite yield the beautiful canonical form conjectured by Nambu himself for the -ary NP bracket. By making a judicious choice for the ‘extra constant of motion’ of namely, and , which are the orientation angles in Kepler problem and isotropic harmonic oscillator (HO) respectively, we show that the dynamical systems with dynamical symmetries can be recast in the beautiful form suggested by Nambu. We believe that the techniques used and the theorems suggested by us in this work are of general interest because of their involvement in the transition from Hamiltonian mechanics to Nambu mechanics.

  15. Bonded Bracket Assmebly for Frameless Solar Panels

    Energy Technology Data Exchange (ETDEWEB)

    Murray, Todd [Rayce Americas, Auburn Hills, MI (United States); Jackson, Nick [Rayce Americas, Auburn Hills, MI (United States); Dupont, Luc [ARaymond Tinnerman Industries, Inc., Brunswick, OH (United States); Moser, Jeff [ARaymond Tinnerman Industries, Inc., Brunswick, OH (United States)

    2013-01-30

    In February 2011 the US Department of Energy announced their new Sunshot Initiative. The Sunshot goal is to reduce the total cost of solar energy systems by about 75 percent before the end of the decade. The DOE estimated that a total installed cost of $$1 per watt for photovoltaic systems would be equivalent to 5-6¢/kilowatt hour (kWh) for energy available from the grid. The DOE also estimated that to meet the $1 per watt goal, PV module costs would need to be reduced to $ .50 per watt, balance of systems costs would need to be reduced to $.40 per watt, and power electronic costs would need to reach $.10 per watt. To address the BOS balance of systems cost component of the $1 per watt goal, the DOE announced a funding opportunity called (BOS-X) Extreme Balance of System Hardware Cost Reductions. The DOE identified eight areas within the total BOS costs: 1) installation labor, 2) installation materials, 3) installation overhead and profit, 4) tracker, 5) permitting and commissioning, 6) site preparation, 7) land acquisition, 8) sales tax. The BOS-X funding announcement requested applications in four specific topics;Topic 1: Transformational Building Integrated Photovoltaic (BIPV) Modules; Topic 2: Roof and Ground Mount Innovations; Topic 3: Transformational Photovoltaic System Designs; and Topic 4: Development of New Wind Load Codes for PV Systems.The application submitted by ARaymond Tinnerman reflected the requirements listed in Topic #2, Roof and Ground Mount Innovations. The goal of topic #2 was to develop technologies that would result in the extreme reduction of material and labor costs associated with applications that require physical connections and attachments to roof and ground mount structures. The topics researched in this project included component cost reduction, labor reduction, weight reduction, wiring innovations, and alternative material utilization. The project objectives included; 1) The development of an innovative quick snap bracket assembly

  16. Design of an Orthodontic Torque Simulator for Measurement of Bracket Deformation

    Science.gov (United States)

    Melenka, G. W.; Nobes, D. S.; Major, P. W.; Carey, J. P.

    2013-12-01

    The design and testing of an orthodontic torque simulator that reproduces the effect of archwire rotation on orthodontic brackets is described. This unique device is capable of simultaneously measuring the deformation and loads applied to an orthodontic bracket due to archwire rotation. Archwire rotation is used by orthodontists to correct the inclination of teeth within the mouth. This orthodontic torque simulator will provide knowledge of the deformation and loads applied to orthodontic bracket that will aide clinicians by describing the effect of archwire rotation on brackets. This will also impact that design on new archwirebracket systems by providing an assessment of performance. Deformation of the orthodontic bracket tie wings is measured using a digital image correlation process to measure elastic and plastic deformation. The magnitude of force and moments applied to the bracket though the archwire is also measured using a six-axis load cell. Initial tests have been performed on two orthodontic brackets of varying geometry to demonstrate the measurement capability of the orthodontic torque simulator. The demonstration experiment shows that a Damon Q bracket had a final plastic deformation after a single loading of 0.022 mm while the Speed bracket deformed 0.071 mm. This indicates that the Speed bracket plastically deforms 3.2 times more than the Damon Q bracket for similar magnitude of applied moment. The demonstration experiment demonstrates that bracket geometry affect the deformation of orthodontic brackets and this difference can be detected using the orthodontic torque simulator.

  17. Bracketed morality revisited: how do athletes behave in two contexts?

    Science.gov (United States)

    Kavussanu, Maria; Boardley, Ian D; Sagar, Sam S; Ring, Christopher

    2013-10-01

    The concept of bracketed morality has received empirical support in several sport studies (e.g., Bredemeier & Shields, 1986a, 1986b). However, these studies have focused on moral reasoning. In this research, we examined bracketed morality with respect to moral behavior in sport and university contexts, in two studies. Male and female participants (Study 1: N = 331; Study 2: N = 372) completed questionnaires assessing prosocial and antisocial behavior toward teammates and opponents in sport and toward other students at university. Study 2 participants also completed measures of moral disengagement and goal orientation in both contexts. In most cases, behavior in sport was highly correlated with behavior at university. In addition, participants reported higher prosocial behavior toward teammates and higher antisocial behavior toward opponents in sport than toward other students at university. The effects of context on antisocial behavior were partially mediated by moral disengagement and ego orientation. Our findings extend the bracketed morality concept to prosocial and antisocial behavior.

  18. WELDING SEQUNCE KONSTRUKSI I-BRACKET PADA PEMBANGUNAN CREW BOAT PAN MARINE 10 DI PT JASA MARINA INDAH SEMARANG

    Directory of Open Access Journals (Sweden)

    Samuel Samuel

    2012-02-01

    Full Text Available This study aimed to determine the sequence of welding and the consequences that occur when the sequence of welding / welding sequence without a supported method of anticipating the occurrence of the pull of welding, the following ways to overcome it. All welding procedures have been implemented, but if not followed by the installation of equipment / tools that support the construction of certain sections, there will be pull welding of large, considering the construction of this very vulnerable Bracket I pull the weld. The position taken by the pull of welding, the center of I Bracket less to the left, less right, less rise, and less down. From the results of this study can be obtained data about the sequence of welding, welding method of the right to obtain maximum results for First Bracket construction welding jobs, find ways to overcome / cope in the event that lead to I pull welding Bracket less to the left, less right, less go up, less down, and get the alignment deviation according to the rule that conditioned. Results deviation below the alignment of the top 0.00 mm, bottom 0.15 mm, left 0.15 mm, right 0.17 mm.

  19. The Kauffman bracket and the Jones polynomial in quantum gravity

    CERN Document Server

    Griego, J R

    1995-01-01

    An analysis of the action of the Hamiltonian constraint of quantum gravity on the Kauffman bracket and Jones knot polynomials is proposed. It is explicitely shown that the Kauffman bracket is a formal solution of the Hamiltonian constraint with cosmological constant (\\Lambda) to third order in \\Lambda. The calculation is performed in the extended loop representation of quantum gravity. The analysis makes use of the analytical expressions of the knot invariants in terms of the two and three point propagators of the Chern-Simons theory. Some particularities of the extended loop calculus are considered and the implications of the results to the case of the conventional loop representation are discussed.

  20. On classification of discrete, scalar-valued Poisson Brackets

    CERN Document Server

    Parodi, Emanuele

    2011-01-01

    We address the problem of classifying discrete differential-geometric Poisson brackets (dDGPBs) of any fixed order on target space of dimension 1. It is proved that these Poisson brackets (PBs) are in one-to-one correspondence with the intersection points of certain projective hypersurfaces. In addition, they can be reduced to cubic PB of standard Volterra lattice by discrete Miura-type transformations. Finally, improving a consolidation lattice procedure, we obtain new families of non-degenerate, vector-valued and first order dDGPBs, which can be considered in the framework of admissible Lie-Poisson group theory.

  1. Kauffman brackets, character varieties, and triangulations of surfaces

    CERN Document Server

    Bonahon, Francis

    2010-01-01

    A Kauffman bracket on a surface is an invariant for framed links in the thickened surface, satisfying the Kauffman skein relation and multiplicative under superposition. This includes representations of the skein algebra of the surface. We show how an irreducible representation of the skein algebra usually specifies a point of the character variety of homomorphisms from the fundamental group of the surface to PSL_2(C), as well as certain weights associated to the punctures of the surface. Conversely, we sketch a proof of the fact that each point of the character variety, endowed with appropriate puncture weights, uniquely determines a Kauffman bracket. Details will appear elsewhere.

  2. The effect of a light-emitting diode on shear bond strength of ceramic brackets bonded to feldspathic porcelain with different curing times.

    Science.gov (United States)

    Elekdag-Turk, Selma; Sarac, Y Sinasi; Turk, Tamer; Sarac, Duygu

    2007-06-01

    The aim of this study was to evaluate different curing times of a light-emitting diode (LED) unit on shear bond strength (SBS) of ceramic brackets bonded to feldspathic porcelain. Ceramic brackets were bonded with a light-cured adhesive to 96 feldspathic porcelain facets. Air-borne particle abrasion was performed using 25 mum aluminium trioxide (Al(2)O(3)) with an air abrasion device from a distance of approximately 10 mm at a pressure of 2.5 bars for 4 seconds, then the porcelain surfaces were etched with 9.6 per cent hydrofluoric acid for 2 minutes. After surface preparation of the porcelain specimens, silane was applied. In groups 1 and 2, the adhesive was cured with a quartz-tungsten-halogen (QTH) unit for 10 and 20 seconds, respectively. The LED was used in the standard mode for 3, 5, and 10 seconds for groups 3, 4, and 5, respectively. For the other three groups, the LED was used in the fast mode for 3, 5, and 10 seconds, respectively. The SBS of the brackets was measured on a universal testing machine. The adhesive remnant index (ARI) scores, damage to the porcelain, and fracture of the ceramic bracket bases were determined. No significant differences were observed for SBS between the eight groups (P=0.087). There was no significant difference between the groups' ARI scores, porcelain damage, and bracket base fracture (P=0.340, P=0.985, and P=0.340, respectively). There was a greater frequency of ARI scores of 0 for all groups. Fifty per cent of the porcelain facets displayed damage. Nineteen ceramic bracket base fractures were observed. No significant difference was found for the SBS of the groups with QTH and LED units and curing times. It is reliable to use LED with a 3-second curing time since it provided adequate bond strength for ceramic brackets bonded to porcelain surfaces.

  3. In vitro comparison of the retention capacity of new aesthetic brackets.

    Science.gov (United States)

    Fernandez, L; Canut, J A

    1999-02-01

    Tensile bond strength and bond failure location were evaluated in vitro for two types of aesthetic brackets (non-silanated ceramic, polycarbonate) and one stainless steel bracket, using bovine teeth as the substrate and diacrylate resin as the adhesive. The results show that metallic bracket had the highest bond strength (13.21 N) followed by the new plastic bracket (12.01 N), which does not require the use of a primer. The non-silanated ceramic bracket produced the lowest bond strength (8.88 N). Bond failures occurred mainly between bracket and cement, although a small percentage occurred between the enamel-cement interface with the metal and plastic brackets and within the cement for the plastic bracket. With the ceramic bracket all the failures occurred at the bracket-cement interface. This suggests that the problems of enamel lesions produced by this type of bracket may have been eliminated. The results also show that the enamel/adhesive bond is stronger than the adhesive/bracket bond in this in vitro study.

  4. Torque expression of 0.018 and 0.022 inch conventional brackets

    NARCIS (Netherlands)

    Sifakakis, I.; Pandis, N.; Makou, M.; Eliades, T.; Katsaros, C.; Bourauel, C.

    2013-01-01

    The aim of this study was to assess the effect of the moments generated with low- and high-torque brackets. Four different bracket prescription-slot combinations of the same bracket type (Mini Diamond(R) Twin) were evaluated: high-torque 0.018 and 0.022 inch and low-torque 0.018 and 0.022 inch. Thes

  5. 21 CFR 872.3750 - Bracket adhesive resin and tooth conditioner.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bracket adhesive resin and tooth conditioner. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3750 Bracket adhesive resin and tooth conditioner. (a) Identification. A bracket adhesive resin and tooth conditioner is a...

  6. 亚历山大托槽与传统托槽矫治器矫治初期对牙周健康影响的比较研究%Comparison of perioldontal condition between conventional and Alexander brackets during the early alignment

    Institute of Scientific and Technical Information of China (English)

    王碧娟

    2015-01-01

    Objective To compare the periodontal indices and the proportion of Porphyromonas gingivalis(P.gingivalis)between conventional pre-adjusted brackets and Alexander brackets during the early alignment. Methods Forty patients(10 to 18 years old)were divided into 2 groups(group A:20 patients with Alexander brackets and group B:20 patients with conventional pre- adjusted brackets).Periodontal indices (GI,PLI,SBI and PD)and the proportion of P.gingivalis in the total bacteria in subgingival plagues were examined in both groups,using the polymerase chain reaction (PCR) method. Results No significant difference was found in the indices recorded and the proportion of P.gingivalis between Groups A and B after 3 months of treatment. Conclusion Alexander brackets P.gingivalis did not have an advantage over conventional bracket with respect to the periodontal status during the early alignment.%目的:对比亚历山大托槽与传统托槽矫治器排齐阶段牙周指数及龈下菌斑中牙龈卟啉单胞菌(P. gingivalis)的发展变化。方法:选取10~18周岁接受正畸治疗的患者40例,按矫治器类型分两组。实验组20例,采用ORMCO公司生产的ALEXANDER托槽;对照组20例,采用杭州新亚生产的直丝托槽。由同一医生分别检测40例患者在矫治器戴入前,戴入后3个月检查牙周临床指标(包括牙龈指数、菌斑指数、龈沟出血指数、探诊深度),同时采集龈下菌斑样本,利用荧光实时定量聚合酶链反应检测样本P.gingivalis和总细菌的数量,计算P.gingivalis在总细菌的构成比。分析牙周临床指标和P.gingivalis的构成比在矫治前后的变化情况。结果:治疗3个月后两组间牙周指数(GI、PLI、SBI、PD)及P.gingivalis在总细菌的构成比差异无显著性。结论:ALEXANDER托槽不会更有利于牙周组织的健康,牙周的健康状况取决于口腔卫生状况。

  7. Conditions for efficient chaos-based communication.

    Science.gov (United States)

    Baptista, Murilo S; Macau, Elbert E; Grebogi, Celso

    2003-03-01

    We find the conditions for a chaotic system to transmit a general source of information efficiently. Transmission of information with very low probability of error is possible if the topological entropy of the transmitted wave signal is greater than or equal to the Shannon entropy of the source message minus the conditional entropy coming from the limitations of the channel (such as equivocation by the noise). This condition may not be always satisfied both due to dynamical constraints and due to the nonoptimal use of the dynamical partition. In both cases, we describe strategies to overcome these limitations.

  8. Histological evaluation after electrothermal debonding of ceramic brackets

    Directory of Open Access Journals (Sweden)

    Vignesh Kailasam

    2014-01-01

    Full Text Available Aim: To evaluate the histological changes following electrothermal debonding (ETD of ceramic brackets. Materials and Methods: A total of 50 first premolar teeth from 14 patients were divided into two groups: Group I consisted of 20 teeth which served as control, and the brackets were debonded using conventional pliers. (7 teeth were extracted 24 hours after conventional debonding, 7 teeth were extracted 28 to 32 days after conventional debonding and 6 teeth were extracted 56-60 days after conventional debonding. Group II consisted of 30 teeth and the brackets were debonded using the ETD unit. (10 teeth were extracted 24 hours after ETD, 10 teeth were extracted 28 to 32 days after ETD and 10 teeth were extracted 56-60 days after ETD. Immediately after extraction, the teeth were sectioned and prepared for histological examination. Results: The pulp was normal in most samples of the control group. In group II, mild inflammation was observed in the 24 hour sample while the 28 to 32 day sample showed signs of healing. The 56-60 day sample showed that the pulp was similar to the control group in 6 out of the 10 samples. Conclusion: The ETD of ceramic brackets did not affect the pulp and the changes which were observed, were reversible in nature.

  9. q-deformed Star Products and Moyal Brackets

    CERN Document Server

    Dayi, O F

    1996-01-01

    The standard and anti-standard ordered operators acting on two-dimensional q-deformed phase space are shown to satisfy algebras which can be called W_\\infty. q-star products and q-Moyal brackets corresponding to these algebras are constructed. Some applications like defining q-classical mechanics and q-path integrals are discussed.

  10. Multiple Bracket Function, Stirling Number, and Lah Number Identities

    OpenAIRE

    Coskun, Hasan

    2012-01-01

    The author has constructed multiple analogues of several families of combinatorial numbers in a recent article, including the bracket symbol, and the Stirling numbers of the first and second kind. In the present paper, a multiple analogue of another sequence, the Lah numbers, is developed, and certain associated identities and significant properties of all these sequences are constructed.

  11. Rheocasting an engine mounting bracket in commercial 7075

    CSIR Research Space (South Africa)

    Curle, UA

    2011-07-01

    Full Text Available Wrought aluminium alloys are prone to hot tearing when cast into near-net shapes. This problem can be overcome by the novel casting technique of rheo-processing combined with high pressure die casting. An industrial engine mounting bracket...

  12. Evaluation of Perceived Acceptability, Beauty and Value of Different Orthodontic Brackets

    Directory of Open Access Journals (Sweden)

    Moshkelgosha V

    2015-03-01

    Full Text Available Statement of Problem: Although different types of aesthetic brackets are introduced to orthodontic profession to reduce the complaints about the metallic braces, little studies have been done to assess patient's views regarding the attractiveness and acceptance of such brackets. Objectives: The goal of this study was to evaluate the perceived acceptability, beauty and value of different orthodontic brackets. Materials and Methods: In a cross-sectional study, three groups of subjects consisting of dental school clinic patients, specialty clinic patients, and art students were interviewed. Sample size was decided 116 in each group. The photographic images of six types of brackets which were placed in an adult mouth were shown to the subjects and they were asked to answer the questions that evaluate attractiveness by visual analog scale (VAS, acceptability of different brackets, and willingness to pay (WTP for an aesthetic bracket in comparison to a regular bracket. Reliability was measured by giving questionnaires to 20 respondents by a two-week interval. VAS rating was compared by ANOVA. Mann U Whitney and Chi-square tests were used to compare the acceptability between groups when necessary. Results: The reliability measurement results performed by ICC were 0.86 for attractiveness, 0.6 for acceptability, and 0.93 for WTP questions. Lingual brackets had the highest attractiveness rating while metal brackets were considered the lowest aesthetic appliance by all groups of the study. The acceptability of ceramic bracket was highest in all groups. While most appliances evaluated had average acceptability, the large metallic brackets were rated very low. WTP for aesthetic braces was higher in art students than other groups. Conclusions: Lingual brackets were the most attractive but had very low acceptability rate. Small metal brackets had a good acceptability rate. Large metal brackets were the least attractive and had the lowest acceptability. Parents

  13. The Effect of Different Soft Drinks on the Shear Bond Strength of Orthodontic Brackets

    Directory of Open Access Journals (Sweden)

    M Omid Khoda

    2012-01-01

    Full Text Available Objective: It is proved that acidic soft drinks that are commonly used, have an adverse effect on dental structures, and may deteriorate oral heath of our patients and orthodontic appliances. The aim of this study was to compare the effect of yoghurt drink with other soft drinks on the shear bond strength of orthodontic brackets.Materials and Methods: Seventy-five first premolar teeth extracted for orthodontic purposes were selected and standard twin metal brackets were bonded on the center of buccal surface with No-Mix composite. The teeth were thermocycled for 625 cycles and randomly divided into five groups of artificial saliva, carbonated yoghurt drink with lactic acid base, non-carbonated yoghurt drink with lactic acid base, 7 up with citric acid base and Pepsi with phosphoric acid base. In all groups, the teeth were immersed in liquid for five-minute sessions three times with equal intervening intervals for 3 months. SBS was measured by a universal testing machine with a speed of 0.5mm/min. Data was analyzed statistically by one-way ANOVA.Results: The results showed that mean values for the shear bond strength of carbonated yoghurt drinks, non-carbonated yoghurt drinks, 7up and Pepsi groups were 12.98(+_2.95, 13.26(+_4.00, 16.11(+_4.89, 14.73(+_5.10, respectively. There was no statistically significant difference among the groups (P-value= 0.238Conclusion: Soft drinks used in this study did not decrease the bond strength of the brackets bonded with this specific type of composite.

  14. Formulation of singular theories in a partial Hamiltonian formalism using a new bracket and multi-time dynamics

    CERN Document Server

    Duplij, Steven

    2013-01-01

    A formulation of singular classical theories (determined by degenerate Lagrangians) without constraints is presented. A partial Hamiltonian formalism in the phase space having an initially arbitrary number of momenta (which can be smaller than the number of velocities) is proposed. The equations of motion become first-order differential equations, and they coincide with those of multi-time dynamics, if a certain condition is imposed. In a singular theory, this condition is fulfilled in the case of the coincidence of the number of generalized momenta with the rank of the Hessian matrix. The noncanonical generalized velocities satisfy a system of linear algebraic equations, which allows an appropriate classification of singular theories (gauge and nongauge). A new antisymmetric bracket (similar to the Poisson bracket) is introduced, which describes the time evolution of physical quantities in a singular theory. The origin of constraints is shown to be a consequence of the (unneeded in our formulation) extension...

  15. Adherence of Streptococcus mutans and Candida albicans to different bracket materials

    Directory of Open Access Journals (Sweden)

    Shrinivaasan Nambi Rammohan

    2012-01-01

    Full Text Available Objective: To quantify the adherence of Streptococcus mutans and Candida albicans on brackets made of stainless steel, plastic, ceramic, titanium, and gold, and to evaluate the various sites of adherence of these microorganisms with scanning electron microscopy (SEM. Materials and Methods: Brackets made of stainless steel, plastic, ceramic, titanium, and gold were used. The adherence of S. mutans and C. albicans were studied. The brackets were placed in flat-bottomed vials containing basal medium with 20% sucrose added; the flasks were inoculated with each of the microbial suspensions. The samples were incubated at 37°C for 48 h, after which the brackets were removed. The cells adhering to the glass were counted and the brackets were studied with SEM. Results: When evaluated together, the adherence of S. mutans and C. albicans was increased in the ceramic bracket group. When evaluated separately, metallic brackets had increased number of colony-forming units (CFUs of S. mutans and the use of titanium brackets increased the CFUs of C. albicans. SEM demonstrated that the adherence of S. mutans and C. albicans together varied according to the bracket materials, with ceramic having the greatest and stainless steel having the least adherence. Conclusions: Oral hygiene may be of greater concern with esthetic brackets since this study shows that microbial adhesion is greater with these brackets.

  16. The effect of herbal teas on the shear bond strength of orthodontic brackets.

    Science.gov (United States)

    Ulusoy, Cagri; Müjdeci, Arzu; Gökay, Osman

    2009-08-01

    The present study was conducted to evaluate the effects of some types of herbal tea on the shear bond strength (SBS) of orthodontic brackets to enamel surfaces. The brackets were bonded with Transbond XT to 90 extracted human premolar teeth and divided equally into six groups, that is, black, mint-mate herbal, mint-lemon herbal, and rosehip fruit tea and two control groups, Coca-Cola and distilled water. All groups were conditioned for three 5-minute sessions with equal intervening intervals for 90 days. The initial pH, SBS, and adhesive remnant index (ARI) of the groups were evaluated and the data were analysed statistically by Kruskal-Wallis and Mann-Whitney U-tests, one-way analysis of variance, and Duncan and Z-tests, respectively. Rosehip fruit tea (2.4 +/- 0.07) and Coca-Cola (2.5 +/- 0.05) had the lowest pH values. Coca-Cola (6.04 +/- 1.11 MPa) and rosehip fruit tea (7.26 +/- 1.11 MPa) significantly reduced the SBS to enamel (P 0.05). Except for the Coca-Cola group (ARI score = 0), fracture sites for all other groups were similar with the majority of bond failures at the enamel-adhesive interface (ARI score = 1). Although this experiment could not completely replicate the complex oral environment, it seems to confirm that Coca-Cola and rosehip fruit tea may be a causative factor in bracket-enamel bonding failure.

  17. The Brackets Design and Stress Analysis of a Refinery's Hot Water Pipeline

    Science.gov (United States)

    Zhou, San-Ping; He, Yan-Lin

    2016-05-01

    The reconstruction engineering which reconstructs the hot water pipeline from a power station to a heat exchange station requires the new hot water pipeline combine with old pipe racks. Taking the allowable span calculated based on GB50316 and the design philosophy of the pipeline supports into account, determine the types and locations of brackets. By analyzing the stresses of the pipeline in AutoPIPE, adjusting the supports at dangerous segments, recalculating in AutoPIPE, at last determine the types, locations and numbers of supports reasonably. Then the overall pipeline system will satisfy the requirement of the ASME B31.3.

  18. Investigation into the bond strength of metal brackets to ceramic restoration%瓷修复体与金属托槽粘接强度的实验研究

    Institute of Scientific and Technical Information of China (English)

    王春晔; 邵玶; 赵媛; 徐实谦; 宋冰

    2012-01-01

    Objective To investigate the influence of different bracket base surfaces ( swallow-tail-backed and mesh-backed ) on the bond strength of metal brackets to porcelain. Methods Methods 80 ceramics specimen were randomly and equally divided into 4 groups according to different conditioning techniques: (A)deglazing by grinding and bonding swallow-tail-backed metal brackets, (B)deglazing by grinding and bonding mesh-backed metal brackets.(C) etching with 9.6% hydrofluoric acid(HF) and bonding swallow-tail-backed metal brackets, (D) etching with 9.6% HF and bonding mesh-backed metal brackets. Each group was further divided into 2 groups randomly and equally: (1) all specimens were stored in artificial saliva at 37t: for 24 hours, (2) untreated. Silane coupling agents and Durafill BondTM adhesive were utilized to bond the bracket onto each sample. The shear bond strength and the Adhesive remnant index (ARI) were determined. Results After artificial saliva bath.the swallow-tail-backed groups resulted in a statistically significant higher bond strength. Deglazing specimens,mesh-backed group in which has a statistically significant higher adhesive remnant index (ARI). Conclusion The swallow-tail-backed groups resulted in a higher bond strength (SBS). The deglazing group had a higher SBS than the group of etching with 9.6% hydrofluoric acid(HF) for 3 min.%目的:研究两种不同形状的底板(燕尾状、网状)对正畸金属托槽与瓷修复体粘接强度的影响.方法:根据瓷面处理方式及所粘接托槽的不同,将80个瓷修复体随机平均分为4组:金刚砂车针打磨+燕尾状底板托槽;金刚砂车针打磨+网状底板托槽;9.6%氢氟酸(hydrofluoric acid,HF)酸蚀+燕尾状底板托槽;9.6% HF酸蚀+网状底板托槽.将粘接后的每组瓷修复体随机平均分为2组:组1用37℃人工唾液水浴24h;组2不予处理.用硅烷偶联剂、杜拉菲勒光固化复合树脂充填材料进行粘接.检测抗剪

  19. A comparative study of shear bond strength of orthodontic bracket after acid-etched and Er:YAG treatment on enamel surface

    Science.gov (United States)

    Leão, Juliana C.; Mota, Cláudia C. B. O.; Cassimiro-silva, Patricia F.; Gomes, Anderson S. L.

    2016-02-01

    This study aimed to evaluate the shear bond strength (SBS) of teeth prepared for orthodontic bracket bonding with 37% phosphoric acid and Er:YAG laser. Forty bovine incisors were divided into two groups. In Group I, the teeth were conditioned with 37% phosphoric acid and brackets were bonded with Transbond XT; in Group II, the teeth were irradiated with Er:YAG and bonding with Transbond XT. After SBS test, the adhesive remnant index was determined. Adhesion to dental hard tissues after Er:YAG laser etching was inferior to that obtained after acid etching but exceeded what is believed to be clinically sufficient strength, and therefore can be used in patients.

  20. Prediction of crack growth of surface crack at bracket toe of ship under random wave loading condition%肘板趾端表面裂纹在随机波浪载荷作用下的疲劳扩展预报

    Institute of Scientific and Technical Information of China (English)

    武锐锋; 黄小平

    2012-01-01

    The bracket toe is one of the fatigue hot spots in ship and ocean structures. In this paper, the SIFs of surface cracks at bracket toe are analyzed by 3D FEA and compared with the results of SIF magnification factors of the same size surface crack at T joints calculated by equations recommended in BS7910. Results show that the SIF magnification factor of surface crack at bracket toe at deepest point is close to that of T-butt joints, while the results at surface point are quite different when the crack length is larger than the bracket thickness. The fatigue crack growth of a surface crack at bracket toe in bottom plate of a Ro-Ro passenger ship was predicted by generating series stress amplitude with zero mean stress which the long-term stress range distribution obey Weibull distribution, the stress intensity factors were calculated by FEA results and the T-joint formula in BS7910 respectively, the unique crack growth rate curve model is employed. The welded residual stress effect is considered in the equivalent stress intensity factor amplitude. It shows thai the predicted fatigue lives of the SIF of surface crack at bracket toe calculated by FEA and by the T-joint formula are very close. The formula for calculating the SIF of surface crack at weld toe of T joint are recommended to the SIF calculation of the surface crack at bracket toe. The unique crack growth rate curve model is recommended in prediction of the fatigue crack propagation life of weld toe of ship hull under random wave loads.%肘板趾端是船舶与海洋结构的疲劳热点.文章用三维有限元分析了趾端表面裂纹应力强度因子修正系数的变化规律,并与BS7910推荐的典型节点表面裂纹应力强度因子公式计算结果作了对比,结果表明趾端表面裂纹应力强度因子沿深度方向的放大系数和T型节点相差很小,而表面端点应力强度因子修正系数则当裂纹长度在肘板厚度范围内时和T型节点相差很小,超出后

  1. Femtosecond laser etching of dental enamel for bracket bonding.

    Science.gov (United States)

    Kabas, Ayse Sena; Ersoy, Tansu; Gülsoy, Murat; Akturk, Selcuk

    2013-09-01

    The aim is to investigate femtosecond laser ablation as an alternative method for enamel etching used before bonding orthodontic brackets. A focused laser beam is scanned over enamel within the area of bonding in a saw tooth pattern with a varying number of lines. After patterning, ceramic brackets are bonded and bonding quality of the proposed technique is measured by a universal testing machine. The results are compared to the conventional acid etching method. Results show that bonding strength is a function of laser average power and the density of the ablated lines. Intrapulpal temperature changes are also recorded and observed minimal effects are observed. Enamel surface of the samples is investigated microscopically and no signs of damage or cracking are observed. In conclusion, femtosecond laser exposure on enamel surface yields controllable patterns that provide efficient bonding strength with less removal of dental tissue than conventional acid-etching technique.

  2. EFFECTS OF POTASSIUM NITRATE ON SHEAR BOND STRENGTH OF BRACKETS

    OpenAIRE

    Carrillo Barreto, Diana; Duarte Gómez, Diana; González Acuña, María E.; Madero Gómez, Sandra M.; Morales García, Harold; Delgado, Linda P.; Ordóñez Monak, Ivonne

    2014-01-01

    Introduction: During 2010 the degree research “Effects of potassium nitrate on shear bond strength of brackets” was carried out at Universidad Cooperativa de Colombia in Bogota. Objective: To determine whether the use of desensitizing with potassium nitrate affects the bond bracket strength to enamel. Materials and Methods: Forty-five human premolar teeth were randomly allocated in three groups (n = 15 each). Group 1: control (not treated), Group 2: desensitizer treated and after 24-hour brac...

  3. [Considerations in orthodontic bracket adhesion to hypoplastic and hypomineralized enamel].

    Science.gov (United States)

    Sapir, S

    2007-01-01

    Developmental defects of enamel are frequently observed in the pediatric and orthodontic dental clinic. Proper diagnosis may improve the clinician's dental care. The importance of prevention is emphasized as well as the proper management of adhesion of orthodontic brackets to hypoplastic and hypominerilized enamel. A review of recent research findings in this field is discussed as well as recommendations for clinical management of some common dental defects: hypoplasia, diffuse and demarcated opacities, and amelogenesis imperfecta.

  4. Indirect bonding of brackets: don't wait another day!

    Science.gov (United States)

    Pellan, Pierre

    2007-01-01

    Indirect bonding of orthodontic brackets is nothing new, but the introduction of more recent adhesives has increased the clinical success encountered by clinicians in a significant way. The many advantages of this technique over direct bonding make it worth the change. The aim of this article is to review the different variables of the technique and describe both laboratory and clinical procedures that have worked so well in hundreds of dental offices.

  5. Comparative Analysis of Bracket Slot Dimensions Evaluating Different Manufacturing Techniques

    Science.gov (United States)

    2015-04-24

    Journal of Clinical Orthodontics ; 1976: Volume 10, No. 11:836-850. 24. Roth, RH. Treatment Concepts Using the Fully Preadjusted Three- Dimensional...et al. Assessment of Slot Sizes in Self-Ligating Brackets Using Electron Microscopy. Australian Orthodontic Journal ; 2010: Volume 26, No. 1: 38-41...Hall; 2001 9. Kusy RP. “Two” Much of a Good Thing? Then Let’s Pick One Slot Size and Make it Metric. American Journal of Orthodontics and

  6. Vision based condition assessment of structures

    Energy Technology Data Exchange (ETDEWEB)

    Uhl, Tadeusz; Kohut, Piotr; Holak, Krzysztof; Krupinski, Krzysztof, E-mail: tuhl@agh.edu.pl, E-mail: pko@agh.edu.pl, E-mail: holak@agh.edu.pl, E-mail: krzysiek.krupinski@wp.pl [Department of Robotics and Mechatronics, AGH-University of Science and Technology, Al.Mickiewicza 30, 30-059 Cracow (Poland)

    2011-07-19

    In this paper, a vision-based method for measuring a civil engineering construction's in-plane deflection curves is presented. The displacement field of the analyzed object which results from loads was computed by means of a digital image correlation coefficient. Image registration techniques were introduced to increase the flexibility of the method. The application of homography mapping enabled the deflection field to be computed from two images of the structure, acquired from two different points in space. An automatic shape filter and a corner detector were implemented to calculate the homography mapping between the two views. The developed methodology, created architecture and the capabilities of software tools, as well as experimental results obtained from tests made on a lab set-up and civil engineering constructions, are discussed.

  7. Comparison of Shear Bond Strength of Orthodontic Brackets Bonded to Enamel Prepared By Er:YAG Laser and Conven-tional Acid-Etching

    Directory of Open Access Journals (Sweden)

    M.H. Hosseini

    2012-01-01

    Full Text Available Introduction: The purpose of this study was to compare shear bond strength (SBS of orthodontic brackets bonded to enamel prepared by Er:YAG laser with two different powers and conventional acid-etching.Materials and Methods: Forty-five human premolars extracted for orthodontic purposes were randomly assigned to three groups based on conditioning method: Group 1- conventional etching with 37% phosphoric acid; Group 2- irradiation with Er:YAG laser at 1 W; and Group 3- irradiation with Er:YAG laser at 1.5 W. Metal brackets were bonded on prepared enamel using a light-cured composite. All groups were subjected to thermocycling process. Then, the specimens mounted in auto-cure acryle and shear bond strength were measured using a universal testing machine with a crosshead speed of 0.5 mm per second. After debonding, the amount of resin remaining on the teeth was determined using the adhesive remnant index (ARI scored 1 to 5. One-way analysis of variance was used to compare shear bond strengths and the Kruskal-Wallis test was performed to evaluate differences in the ARI for different etching types.Results: The mean and standard deviation of conventional acid-etch group, 1W laser group and 1.5W laser group was 3.82 ± 1.16, 6.97 ± 3.64 and 6.93 ± 4.87, respectively.Conclusion: The mean SBS obtained with an Er:YAG laser operated at 1W or 1.5W is approximately similar to that of conventional etching. However, the high variability of values in bond strength of irradiated enamel should be considered to find the appropriate parameters for applying Er:YAG laser as a favorable alternative for surface conditioning.

  8. Load-deflection and surface properties of coated and conventional superelastic orthodontic archwires in conventional and metal-insert ceramic brackets

    Directory of Open Access Journals (Sweden)

    Shiva Alavi

    2012-01-01

    Full Text Available Background: Properties of coated archwires, which have been introduced for esthetic demands during orthodontic treatments, along with the use of tooth-colored brackets, are not clear. The aim of this study is to compare the load-deflection and surface properties of coated superelastic archwires with conventional superelastic archwires in conventional and metal-insert ceramic brackets. Materials and Methods: In this experimental study, 3 types of archwires including ultraesthetic polycoated, ultraesthetic epoxyresin coated and conventional (uncoated superelastic nickel-titanium (NiTi archwires were used in each of 2 types of brackets including conventional and metal-insert ceramic. To simulate oral environment, all specimens were incubated in artificial saliva using thermocycling model and then were tested in three-bracket bending test machine. Loading and unloading forces, plateau gap and end load deflection point (ELDP were recorded. Archwires were investigated with a stereomicroscope before and after the experiment. Two-way ANOVA and Tukey tests were used at P<0.05. Results: Epoxyresin archwires produced lower forces (19 to 310 gr compared to polycoated (61 to 359 gr and NiTi (61 to 415 gr (P<0.0001. The maximum ELDP (0.43 mm was observed in epoxyresin archwires (P<0.001. Coatings of some epoxyresin wires were torn and of polycoated wires peeled off. Conventional ceramic bracket produced higher loading forces with polycoated and NiTi archwires and lower unloading forces with all 3 types of archwires compared to metal-insert type (P<0.05. Conclusion: Epoxyresin-coated archwire had the lowest force and highest ELDP. Coatings were not durable in these experimental conditions. Conventional ceramic bracket produced higher frictional force compared to metal-insert type.

  9. A comparative assessment of torque generated by lingual and conventional brackets.

    Science.gov (United States)

    Sifakakis, Iosif; Pandis, Nikolaos; Makou, Margarita; Eliades, Theodore; Katsaros, Christos; Bourauel, Christoph

    2013-06-01

    The aim of this study was to assess the effect of bracket type on the labiopalatal moments generated by lingual and conventional brackets. Incognito™ lingual brackets (3M Unitek), STb™ lingual brackets (Light Lingual System; ORMCO), In-Ovation L lingual brackets (DENTSPLY GAC), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded on identical maxillary acrylic resin models with levelled and aligned teeth. Each model was mounted on the orthodontic measurement and simulation system and 10 0.0175 × 0.0175 TMA wires were used for each bracket type. The wire was ligated with elastomerics into the Incognito, STb, and conventional brackets and each measurement was repeated once after religation. A 15 degrees buccal root torque (+15 degrees) and then a 15 degrees palatal root torque (-15 degrees) were gradually applied to the right central incisor bracket. After each activation, the bracket returned to its initial position and the moments in the sagittal plane were recorded during these rotations of the bracket. One-way analysis of variance with post hoc multiple comparisons (Tukey test at 0.05 error rate) was conducted to assess the effect on bracket type on the generated moments. The magnitude of maximum moment at +15 degrees ranged 8.8, 8.2, 7.1, and 5.8 Nmm for the Incognito, STb, conventional Gemini, and the In-Ovation L brackets, respectively; similar values were recorded at -15 degrees: 8.6, 8.1, 7.0, and 5.7 Nmm, respectively. The recorded differences of maximum moments were statistically significant, except between the Incognito and STb brackets. Additionally, the torque angles were evaluated at which the crown torque fell well below the minimum levels of 5.0 Nmm, as well as the moment/torque ratio at the last part of the activation/deactivation curve, between 10 and 15 degrees. The lowest torque expression was observed at the self-ligating lingual brackets, followed by the conventional brackets. The Incognito and STb lingual brackets

  10. Effect of Saliva Contamination on Shear Bond Strength of Orthodontic Brackets When Using a Self-Etch Primer

    Institute of Scientific and Technical Information of China (English)

    MAO Jing; QI Juan

    2005-01-01

    The effect of saliva contamination on the shear bond strength of orthodontic brackets, at various stages of the bonding procedure using a new self-etch primer was studied. The samples were divided into 4 groups according to 4 different enamel surface conditions: Group A: dry; Group B: saliva contamination before priming; Group C: saliva contamination after priming, and Group D: saliva contamination before and after priming. Stainless steel brackets were bonded in each test group with a light-cured composite resin (TransbondXT 3M). The shear bond strength was determined in the first 30 min after bonding. The analysis of variance indicated that the shear bond strengths of the 4 groups were significantly different (F= 11.89, P<0.05). Tukey HSD tests indicated that contamination both before and after the application of the acid-etch primer resulted in a significantly lower (=4.6± 1.7 MPa) shear bond strength than either the control group (= 8.8±1.9 MPa) or the groups where contamination occurred either before ( = 7.9± 2.0 MPa) or after (=6.9±1.5 MPa) the application of the primer. It was concluded that the new acid-etch primer could maintain adequate shear bond strength if contamination occurred either before or after the application of the primer. On the other hand, contamination both before and after the application of the primer could significantly reduce the shear bond strength of orthodontic brackets.

  11. Concurrent engineering solution for the design of ship and offshore bracket parts and fabrication process

    Science.gov (United States)

    Kim, Tae-Won; Lim, Sang-Sub; Seok, Ho-Hyun; Kang, Chung-Gil

    2013-09-01

    Brackets in ships and offshore structures are added structures that can endure stress concentrations. In this study, a concurrent engineering solution was proposed, and a high strength low carbon cast steel alloy applicable to offshore structures was designed and developed. The yield strength and ultimate tensile strength of the designed steel were 480 and 600 MPa, respectively. The carbon equivalent of the steel was 0.446 with a weld crack susceptibility index of 0.219. The optimal structural design of the brackets for offshore structures was evaluated using ANSYS commercial software. The possibility of replacing an assembly of conventional built-up brackets with a single casting bulb bracket was verified. The casting process was simulated using MAGMAsoft commercial software, and a casting fabrication process was designed. For the proposed bulb bracket, it was possible to reduce the size and weight by approximately 30% and 50%, respectively, compared to the conventional type of bracket.

  12. Condition based maintenance in the context of opportunistic maintenance

    NARCIS (Netherlands)

    Koochaki, Javid; Bokhorst, Jos A. C.; Wortmann, Hans; Klingenberg, Warse

    2012-01-01

    Condition based maintenance (CBM) uses the operating condition of a component to predict a failure event. Compared to age based replacement (ABR), CBM usually results in higher availability and lower maintenance costs, since it tries to prevent unplanned downtime and avoid unnecessary preventive mai

  13. Condition based maintenance in the context of opportunistic maintenance

    NARCIS (Netherlands)

    Koochaki, Javid; Bokhorst, Jos A. C.; Wortmann, Hans; Klingenberg, Warse

    2012-01-01

    Condition based maintenance (CBM) uses the operating condition of a component to predict a failure event. Compared to age based replacement (ABR), CBM usually results in higher availability and lower maintenance costs, since it tries to prevent unplanned downtime and avoid unnecessary preventive

  14. Performance of Numerical Boundary Condition based on Active Wave Absorption

    DEFF Research Database (Denmark)

    Troch, Peter; De Rouck, Julien; Frigaard, Peter

    2001-01-01

    The performance of a new active wave generating-absorbing boundary condition for a numerical model based on the Volume Of Fluid (VOF) method for tracking free surfaces is presented.......The performance of a new active wave generating-absorbing boundary condition for a numerical model based on the Volume Of Fluid (VOF) method for tracking free surfaces is presented....

  15. Stretched graphene tented by polycaprolactone and polypyrrole net-bracket for neurotransmitter detection

    Science.gov (United States)

    Wang, Zhenzhen; Ying, Ye; Li, Li; Xu, Ting; Wu, Yiping; Guo, Xiaoyu; Wang, Feng; Shen, Haojie; Wen, Ying; Yang, Haifeng

    2017-02-01

    A net-bracket built out from the core@shell structure of chemically oxidized polypyrrole (PPy) coated electrospun polycaprolactone (PCL) nanofibers, and the following surface modification of a thin layer of positively charged poly(dimethyl diallyl ammonium chloride) (PDDA) has been applied for stretching the reduced graphene oxide (RGO) sheets to some extent with the electrochemical deposition method. The as-formed RGO/PDDA/PCL@PPy nanocomposites were investigated by using scanning electron microscopy, transmission electron microscope, X-ray diffraction and Raman spectroscopy. The graphene tented by the net-bracket showed remarkable electrocatalytic properties in detecting the neurotransmitter dopamine (DA). Low detection limit of 0.34 μM (S/N = 3) with the wide linear detection range from 4 μM to 690 μM was obtained. The successful determination of DA in real urine samples and DA injection were achieved. Such attractive fabrication strategy can be extended to make other graphene sheet-based sensors.

  16. Influence of different orthodontic brackets on adherence of microorganisms in vitro.

    Science.gov (United States)

    Brusca, M I; Chara, O; Sterin-Borda, L; Rosa, A C

    2007-03-01

    To define the capacity of different bracket materials to modify the growth and adherence of microorganisms. Three types of brackets from the right upper central incisor were used: metallic, ceramic, and composite. Streptococcus mutans and Candida albicans were studied. The association of both species was also evaluated. The brackets were placed in flat-bottomed vials containing basal medium with 20% sucrose added; the flasks were inoculated with each of the microbial suspensions. The samples were incubated at 37 degrees C for 48 hours, after which the brackets were removed. The supernatant was removed from the flasks, the cells adhering to the glass were counted, and the brackets were studied with electron microscopy. The adherence of Streptococcus mutans was not modified by the different brackets. The adherence of Candida albicans was increased by the composite bracket, whereas the use of metallic brackets decreased the number of colony-forming units (CFUs). By electron microscopy we demonstrated that the adherence of Streptococcus mutans plus Candida albicans together varied according to the bracket materials with composite > ceramic > metallic. Orthodontic appliances serve as different impact zones and modify microbial adherence and colonization, acting as foreign reserves and possible sources of infection.

  17. Forces in the presence of ceramic versus stainless steel brackets with unconventional vs conventional ligatures.

    Science.gov (United States)

    Baccetti, Tiziano; Franchi, Lorenzo; Camporesi, Matteo

    2008-01-01

    To compare the forces resulting from four types of bracket/ligature combinations: ceramic brackets and stainless steel brackets combined with unconventional elastomeric ligatures (UEL) and conventional elastomeric ligatures (CEL) during the leveling and aligning phases of orthodontic therapy. The testing model consisted of five 0.022-inch preadjusted brackets (second premolar, first premolar, canine, lateral incisor, and central incisor) for each of the two bracket types. The canine bracket was welded to a sliding bar that allowed for different amounts of offset in the gingival direction. The forces generated by a 0.014-inch superelastic nickel titanium wire in the presence of either the UEL or CEL bracket/ligature systems at different amounts of upward canine misalignment (1.5 mm, 3 mm, 4.5 mm, and 6 mm) were recorded. Significant differences were found between UEL and CEL systems for all tested variables (P force in the presence of CEL was negligible with 3.0 mm or greater of canine misalignment. On the contrary, during alignment, a force available for tooth movement was recorded in the presence of both ceramic and stainless steel brackets when associated with UEL. The type of ligature used influenced the actual amount of force released by the orthodontic system significantly more than the type of bracket used (stainless steel vs ceramic).

  18. Geometry of Vlasov kinetic moments: A bosonic Fock space for the symmetric Schouten bracket

    Energy Technology Data Exchange (ETDEWEB)

    Gibbons, John [Department of Mathematics, Imperial College London, London SW7 2AZ (United Kingdom); Holm, Darryl D. [Department of Mathematics, Imperial College London, London SW7 2AZ (United Kingdom); Computer and Computational Science Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Tronci, Cesare [Department of Mathematics, Imperial College London, London SW7 2AZ (United Kingdom); TERA Foundation for Oncological Hadrontherapy, 11 V. Puccini, Novara 28100 (Italy)], E-mail: cesare.tronci@imperial.ac.uk

    2008-06-02

    The dynamics of Vlasov kinetic moments is shown to be Lie-Poisson on the dual Lie algebra of symmetric contravariant tensor fields. The corresponding Lie bracket is identified with the symmetric Schouten bracket and the moment Lie algebra is related with a bundle of bosonic Fock spaces, where creation and annihilation operators are used to construct the cold plasma closure. Kinetic moments are also shown to define a momentum map, which is infinitesimally equivariant. This momentum map is the dual of a Lie algebra homomorphism, defined through the Schouten bracket. Finally the moment Lie-Poisson bracket is extended to anisotropic interactions.

  19. Evaluation of Friction in Orthodontics Using Various Brackets and Archwire Combinations-An in Vitro Study

    Science.gov (United States)

    Kumar, Sujeet; Hamsa P.R, Rani; Ahmed, Sameer; Prasanthma; Bhatnagar, Apoorva; Sidhu, Manreet; Shetty, Pramod

    2014-01-01

    AIM: The aim of this study was to compare frictional resistance which was produced between conventional brackets (0.022 slot Otho-Organiser) and self ligating brackets (active Forestadent and passive Damon III) by using various arch wire combinations (0.016 Niti, 0.018 Niti, 0.017 x 0.025 SS and 0.019 x 0.025 SS). Methods: An experimental model which consisted of 5 aligned stainless steel 0.022-in brackets was used to assess frictional forces which were produced by SLBs (self ligating brackets) and CELs (conventional elastomeric ligatures) with use of 0.016 nickel titanium, 0.018 nickel titanium, 0.017 X 0.025”stainless steel and 0.019 X 0.025”stainless steel wires. Statistical analysis: One way ANOVA test was used to study the effect of the bracket type, wire alloy and section on frictional resistance test . Results: Conventional brackets produced highest levels of friction for all bracket/archwire combinations. Both Damon III and Forestadent brackets were found to produce significantly lower levels of friction when they were compared with elastomerically tied conventional brackets. Conclusion: SLBs are valid alternatives for low friction during sliding mechanics. PMID:24995241

  20. Elemental composition of brazing alloys in metallic orthodontic brackets.

    Science.gov (United States)

    Zinelis, Spiros; Annousaki, Olga; Eliades, Theodore; Makou, Margarita

    2004-06-01

    The aim of this study was to assess the elemental composition of the brazing alloy of representative orthodontic brackets. The brackets examined were Gemini (3M, Unitec, Monrovia, Calif), MicroLoc (GAC, Bohemia, NY), OptiMESHxrt (Ormco, Glendora, Calif), and Ultratrim (Dentarum, Ispringen, Germany). Four metallic brackets for each brand were embedded in epoxy resin and after metallographic grinding and polishing were cleaned in a water ultrasonic bath. Scanning electron microscopy and energy-dispersive x-ray microanalysis (EDS) were used to assess the quantitative composition of the brazing alloy. Four EDS spectra were collected for each brazing alloy, and the mean value and standard deviation for the concentration of each element were calculated. The elemental composition of the brazing alloys was determined as follows (percent weight): Gemini: Ni = 83.98 +/- 1.02, Si = 6.46 +/- 0.37, Fe = 5.90 +/- 0.93, Cr = 3.52 +/- 0.34; MicroLoc: Ag = 42.82 +/- 0.18, Au = 32.14 +/- 0.65, Cu = 24.53 +/- 0.26, Mg = 1.12 +/- 0.33; OptiMESHxrt: Au = 67.79 +/- 0.97, Fe = 15.69 +/- 0.29, Ni = 13.01 +/- 0.93, Cr = 4.01 +/- 0.35; Ultratrim: Ag = 87.97 +/- 0.33, Cu = 10.51 +/- 0.45, Mg = 1.29 +/- 0.63, Zn = 1.13 +/- 0.24. The findings of this study showed that different brazing materials were used for the different brands, and thus different performances are expected during intraoral exposure; potential effects on the biological properties also are discussed.

  1. Comparison of Self-Etch Primers with Conventional Acid Etching System on Orthodontic Brackets

    Science.gov (United States)

    Zope, Amit; Zope-Khalekar, Yogita; Chitko, Shrikant S.; Kerudi, Veerendra V.; Patil, Harshal Ashok; Jaltare, Pratik; Dolas, Siddhesh G

    2016-01-01

    Introduction The self-etching primer system consists of etchant and primer dispersed in a single unit. The etching and priming are merged as a single step leading to fewer stages in bonding procedure and reduction in the number of steps that also reduces the chance of introduction of error, resulting in saving time for the clinician. It also results in smaller extent of enamel decalcification. Aim To compare the Shear Bond Strength (SBS) of orthodontic bracket bonded with Self-Etch Primers (SEP) and conventional acid etching system and to study the surface appearance of teeth after debonding; etching with conventional acid etch and self-etch priming, using stereomicroscope. Materials and Methods Five Groups (n=20) were created randomly from a total of 100 extracted premolars. In a control Group A, etching of enamel was done with 37% phosphoric acid and bonding of stainless steel brackets with Transbond XT (3M Unitek, Monrovia, California). Enamel conditioning in left over four Groups was done with self-etching primers and adhesives as follows: Group B-Transbond Plus (3M Unitek), Group C Xeno V+ (Dentsply), Group D-G-Bond (GC), Group E-One-Coat (Coltene). The Adhesive Remnant Index (ARI) score was also evaluated. Additionally, the surface roughness using profilometer were observed. Results Mean SBS of Group A was 18.26±7.5MPa, Group B was 10.93±4.02MPa, Group C was 6.88±2.91MPa while of Group D was 7.78±4.13MPa and Group E was 10.39±5.22MPa respectively. In conventional group ARI scores shows that over half of the adhesive was remaining on the surface of tooth (score 1 to 3). In self-etching primer groups ARI scores show that there was no or minor amount of adhesive remaining on the surface of tooth (score 4 and 5). SEP produces a lesser surface roughness on the enamel than conventional etching. However, statistical analysis shows significant correlation (p<0.001) of bond strength with surface roughness of enamel. Conclusion All groups might show clinically

  2. Esthetic dentistry for multiple gingival recession cases: Coronally advanced flap with bracket application

    Directory of Open Access Journals (Sweden)

    Minkle Gulati

    2016-01-01

    Full Text Available Treatment of gingival recession is essential to rectify the esthetic and functional deficiencies of the patient and to combat further periodontal destruction. However, treating multiple recession cases is quite challenging, and therefore requires constant modifications of the prevalent treatment strategies as per the severity of the condition. The objective of this case report was to evaluate the effectiveness of coronally advanced flap (CAF technique without vertical incisions using CAF brackets (CAF+B for treating a patient presenting with class II gingival recession defects in relation to maxillary anteriors. Complete root coverage was observed, and the results were consistent even after 6 months. The current case report demonstrates good outcomes of the CAF + B technique without the use of any additional soft tissue grafts or vertical incisions, therefore, endorsing the promising potential of the CAF + B technique in multiple gingival recession cases.

  3. The anticorrosion ability of titanium nitride (TiN) plating on an orthodontic metal bracket and its biocompatibility.

    Science.gov (United States)

    Kao, Chia-Tze; Ding, Shinn-Jyh; Chen, Yu-Chih; Huang, Tsui-Hsien

    2002-01-01

    Typically, an orthodontic metal bracket is made from stainless steel. It has been shown that such metal may corrode in an acid- and chloride-rich environment. The purpose of the current study was to investigate a titanium nitride (TiN) ion-plated stainless steel orthodontic bracket's anticorrosion properties and compare its biocompatibility with that of non-TiN-plated brackets. The stainless-steel brackets studied here were tested in acidic artificial saliva. The plated metal bracket was produced by the titanium nitride (TiN) ion-plating method. The TiN-plating on the bracket surface was demonstrated to be successful by EDX analysis. The quantity of metallic-ion release under test immersion solutions was analyzed by atomic absorption spectrophotometry. Both TiN- and non-TiN-plated brackets may release detectable ions into the test solution, including nickel, chromium, manganese, copper, and iron (ferric). The anticorrosion ability of the plated bracket was analyzed by means of inductively coupled plasma atomic emission spectroscopy. The results revealed that the TiN-plated metal bracket did not increase the anticorrosion ability of the standard bracket. The biocompatibility of the TiN plating versus the standard bracket material resulting from bracket immersion in the test solution revealed no toxicity on U2OS cells using a methylthiazole tetrazolium (MTT) colorimetric assay. Clearly, the search for an improved technique for enhancing the anticorrosion ability of the normal metal orthodontic bracket should be continued. Copyright 2002 Wiley Periodicals, Inc.

  4. Catalog of 199 register-based definitions of chronic conditions

    DEFF Research Database (Denmark)

    Hvidberg, Michael F; Johnsen, Søren P; Glümer, Charlotte

    2016-01-01

    definitions were proposed based on record linkage between multiple registers, including registers of prescribed drugs and use of general practitioners' services. CONCLUSIONS THIS STUDY PROVIDED A CATALOG OF REGISTER-BASED DEFINITIONS FOR CHRONIC CONDITIONS FOR USE IN HEALTHCARE PLANNING AND RESEARCH, WHICH IS......INTRODUCTION: The aim of the current study was to present and discuss a broad range of register-based definitions of chronic conditions for use in register research, as well as the challenges and pitfalls when defining chronic conditions by the use of registers. MATERIALS AND METHODS......: The definitions were defined based on information from nationwide Danish public healthcare registers. Medical and epidemiological specialists identified and grouped relevant diagnosis codes that covered chronic conditions, using the International Classification System version 10 (ICD-10). Where relevant...

  5. Knowledge Management for Large Scale Condition Based Maintenance

    Data.gov (United States)

    National Aeronautics and Space Administration — This presentation will review the use of knowledge management in the development and support of Condition Based Maintenance (CBM) systems for complex systems with...

  6. Optimized Design of Injection Mould of Vacuum Cup Bracket Based on CAE Technique%基于CAE技术的强吸式塑料置物架注射模具的优化设计

    Institute of Scientific and Technical Information of China (English)

    李菊丽; 郭华锋; 周元凯

    2011-01-01

    根据塑件的结构特点,基于Moldflow软件进行了模流分析,确定了注射模具的最佳方案,保证了塑件质量,利用PRO/E软件设计出了整副模具.结果表明,利用CAD/CAE技术可以加快模具设计进程,规避设计缺陷,提高生产效率.%According to the structure characteristics of plastics, mould flow analysis was done based on the Moldflow software. The best solution was determined; the quality of the surface was guaranteed. The whole mold was designed based on PRO/E software. The results show that the mould design process could be accelerated by using CAD/CAE technology, the design flaws could be avoided, production efficiency could be improved.

  7. 某重卡下支架有限元分析及轻量化设计%Finite element analysis and Lightweight Design of A Heavy TruckLower bracket

    Institute of Scientific and Technical Information of China (English)

    张龙; 王晓磊; 张阳光; 冯江峰

    2014-01-01

    Finite element analysis was performed on the static strength properties under design conditions of a heavy truck lower bracket, and lightweight design was performed. Using topology optimization method, iterative calculations for optimization were performed, the maximum design space was taken as the base structure of optimization, the lightest weight was taken as the objective function, the structural static strength properties was taken as the constraints. After the lightweight design, the lower bracket weight was reduced, and the lightweight structure met strength requirements.%对某重卡下支架在设计工况下的静强度性能进行了有限元分析,并对该下支架结构进行了轻量化设计。采用拓扑优化方法,以最大设计空间为优化的基结构,以重量最轻为目标函数,以结构的静强度性能为约束条件,进行了优化迭代计算。轻量化设计后,减轻了下支架的重量,且轻量化结构满足强度要求。

  8. Affine bracket algebra theory and algorithms and their applications in mechanical theorem proving

    Institute of Scientific and Technical Information of China (English)

    Ning ZHANG; Hong-bo LI

    2007-01-01

    This paper discusses two problems: one is some important theories and algorithms of affine bracket algebra; the other is about their applications in mechanical theorem proving. First we give some efficient algorithms including the boundary expanding algorithm which is a key feature in application. We analyze the characteristics of the boundary operator and this is the base for the implementation of the system. We also give some new theories or methods about the exact division, the representations and structure of affine geometry and so on. In practice, we implement the mechanical auto-proving system in Maple 10 based on the above algorithms and theories. Also we test about more than 100 examples and compare the results with the methods before.

  9. Affine bracket algebra theory and algorithms and their applications in mechanical theorem proving

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    This paper discusses two problems:one is some important theories and algorithms of affine bracket algebra;the other is about their applications in mechanical theorem proving.First we give some efficient algorithms including the boundary expanding algorithm which is a key feature in application.We analyze the characteristics of the boundary operator and this is the base for the implementation of the system.We also give some new theories or methods about the exact division,the representations and structure of affine geometry and so on.In practice,we implement the mechanical auto-proving system in Maple 10 based on the above algorithms and theories.Also we test about more than 100 examples and compare the results with the methods before.

  10. A Framework for Intelligent Condition-based Maintenance of Rotating Equipment using Mechanical Condition Monitoring

    Directory of Open Access Journals (Sweden)

    Tahan B. Mohammadreza

    2014-07-01

    Full Text Available The ideal end result of maintenance strategy is to increase profitability, improve product quality and ensure safety conditions. In condition-based maintenance (CBM, asset health is monitored regularly to maximize reliability and availability by determining necessary maintenance at the right time. Review of recent studies shows most of developed approaches propose a standalone system for each stage of maintenance system. In order to standardize a generic architecture for machinery CBM, this paper attempts to introduce an intelligent framework consisting of several functional modules, starting from data acquisition and ending to advisory generation, with the emphasis on approaches of condition monitoring and maintenance decision-making.

  11. Complex brackets and balanced complex 1st-order difference polynomials in 4-dimensional Minkowski space

    Institute of Scientific and Technical Information of China (English)

    HUANG Lei; LI HongBo

    2008-01-01

    This paper investigates complex brackets and balanced complex 1st-order difference (BCD) polynomials. Then we propose an algorithm of O(nlog n) complexity to check the equality of brackets. It substitutes exponential algorithms before. Also, BCD polynomials have some usages in geometric calculation.

  12. Gingival response in orthodontic patients: Comparative study between self-ligating and conventional brackets.

    Science.gov (United States)

    Folco, Alejandra A; Benítez-Rogé, Sandra C; Iglesias, Marina; Calabrese, Diana; Pelizardi, Cristina; Rosa, Alcira; Brusca, Marisa I; Hecht, Pedro; Mateu, María E

    2014-01-01

    Orthodontic brackets contribute to the accumulation of bacterial plaque on tooth surfaces because they hinder oral hygiene. In contrast to conventional brackets, self-ligating brackets do not require additional parts to support the arches, thus improving dental hygiene. The aim of this study was to compare the gingival response in orthodontic patients wearing self-ligating or conventional brackets. A sample of 22 patients aged 16 to 30 years was divided into two groups: Group A, treated with selfligating brackets (Damon system) and Group B, treated with conventional brackets (Roth technique). The following were assessed during the treatment: Plaque Index (PI), Gingival Index (GI) and Probing Depth (PD), and sub-gingival samples were taken from teeth 14/24 for microbiological observation. No statistically significant difference was found between Groups A and B; p>0.05 (sign-ranked) or between PI, GI and PD at the different times (Friedman's Analysis of Variance), even though the indices were found to increase at 14 days, particularly for self-ligating brackets. The quantity and quality of microorganisms present were compatible with health on days 0, 28 and 56. As from day 14 there is a predominance of microbiota compatible with gingivitis in both groups. In the samples studied, orthodontic treatment increases bacterial plaque and inflammatory gingival response, but gingival-periodontal health can be maintained with adequate basic therapy. Self-ligating and conventional brackets produced similar gingival response.

  13. Influence of Tm:YAP laser irradiation on tensile strength for bracket debonding

    Science.gov (United States)

    Dostalova, Tatjana; Jelinkova, Helena; Sulc, Jan; Koranda, Petr; Nemec, Michal; Fibrich, Martin; Jelinek, Michal; Michalik, Pavel; Miyagi, Mitsunobu

    2011-03-01

    The investigation of tensile strength needed for bracket debonding was the aim of study. A diode pumped Tm: YAP microchip laser generating a continuous 2um radiation with the maximum output power of 4W was used for debonding purposes. The group of 60 brackets was debonded using classical and laser irradiation methods - the doze from 1W to 4 W, 60s. The tensile strength without laser irradiation was in the range from 39.6 N (full ceramic bracket group) to 63.7 N (ceramic bracket with metal slot group). After irradiation the tensile strength was decreased from 35.1 N (full ceramic bracket group) to 48.8 N (ceramic bracket with metal slot group). The results of our study generally agree with the previous studies, substantiating the fact that lasers can be used effectively to thermally soften the adhesive resin for removal of ceramic brackets. From the practical point of view is conclusion that during laser irradiation, thermal ablation occurs and the bracket is removed from the enamel together with the rest of the adhesive resin. Laser debonding is easier and little heat diffusion occurred.

  14. Complex brackets and balanced complex 1st-order difference polynomials in 4-dimensional Minkowski space

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    This paper investigates complex brackets and balanced complex 1st-order di?erence (BCD) polynomials. Then we propose an algorithm of O(n log n) complexity to check the equality of brackets. It substitutes exponential algorithms before. Also, BCD polynomials have some usages in geometric calculation.

  15. Forces produced by different nonconventional bracket or ligature systems during alignment of apically displaced teeth.

    Science.gov (United States)

    Baccetti, Tiziano; Franchi, Lorenzo; Camporesi, Matteo; Defraia, Efisio; Barbato, Ersilia

    2009-05-01

    To analyze the forces released by four types of passive stainless steel self-ligating brackets (SLBs), and by two nonconventional elastomeric ligature-bracket systems when compared with conventional elastomeric ligatures on conventional stainless steel brackets during the alignment of apically displaced teeth at the maxillary arch. An experimental model consisting of five brackets was used to assess the forces released by the seven different ligature-bracket systems with 0.012'' or 0.014'' superelastic nickel titanium wire in the presence of different amounts of apical displacement of the canine (ranging from 1.5 mm to 6 mm). Comparisons between the different types of bracket/wire/ ligature systems were carried out by means of ANOVA on ranks with Dunnett's post hoc test (P force for alignment is generated by passive SLBs and nonconventional elastomeric ligature-bracket systems, and a null amount of force is released in the presence of conventional elastomeric ligatures on conventional brackets. When minimal apical displacement is needed (1.5 mm), the differences in performance between low-friction and conventional systems are minimal. These differences become significant when correction of a misalignment of greater than 3.0 mm is attempted.

  16. Loss of surface enamel after bracket debonding : An in-vivo and ex-vivo evaluation

    NARCIS (Netherlands)

    Pont, Huib Berghauser; Özcan, Mutlu; Bagis, Bora; Ren, Yijin

    2010-01-01

    INTRODUCTION: The objective of this study was to evaluate the surface enamel after bracket debonding and residual resin removal. METHODS: Thirty patients (female, 20; male, 10; mean age, 18.4 years) who completed orthodontic treatment with fixed appliances (Twin Brackets, 3M Unitek, Monrovia, Calif)

  17. Comparison of static friction with self-ligating, modified slot design and conventional brackets

    Directory of Open Access Journals (Sweden)

    Raquel Morais Castro

    2013-07-01

    Full Text Available OBJECTIVE: To compare the static frictional forces generated at the bracket/wire interface of stainless steel brackets with different geometries and angulations, combined with orthodontic wires of different diameters. MATERIAL AND METHODS: The frictional forces were evaluated with three different types of metal brackets: a passive self-ligating (SmartClipTM, 3M/Unitek, Monrovia, USA, with a modified slot design (Mini Uni TwinTM, 3M/Unitek, Monrovia, USA and conventional (Kirium, Abzil, São José do Rio Preto, Brazil. The samples were mounted in a testing device with three different angulations and tested with 0.014" and 0.018" stainless steel wires (American Orthodontics, Sheboygan, USA. The static frictional force was measured using a universal testing machine (DL 500, EMIC®, São José dos Pinhais, Brazil with a crosshead speed of 1 mm/min. Statistical analysis was performed by two-way ANOVA followed by Bonferroni's post hoc test. RESULTS: There was a significant difference (p<0.05 in static friction when the three types of brackets were tested with the same wire size. The wire diameter influenced friction only when the brackets had a 10º angulation (p<0.05. The angulation influenced friction (p<0.05 when the brackets were associated with a 0.018" wire. CONCLUSION: Brackets with a modified slot design showed intermediate static frictional force values between the conventional and self-ligating brackets tested.

  18. Magnetic resonance imaging artifacts caused by brackets of various materials - An in vivo study

    Directory of Open Access Journals (Sweden)

    Deepti Razdan

    2012-01-01

    Patients who might require repeated MRI scans, can be treated orthodontically with ceramic/composite/anterior ceramic and posterior stainless steel brackets. When the region of interest is above the orbit or beyond the posterior wall of the pharynx, no demonstrable artifacts were recorded with various types of brackets included in the present study.

  19. Caries outcomes after orthodontic treatment with fixed appliances: do lingual brackets make a difference?

    NARCIS (Netherlands)

    van der Veen, M.H.; Attin, R.; Schwestka-Polly, R.; Wiechmann, D.

    2010-01-01

    Orthodontic treatment with fixed appliances is considered a risk factor for the development of white spot caries lesions (WSL). Traditionally, brackets are bonded to the buccal surfaces. Lingual brackets are developing rapidly and have become more readily available. Buccal surfaces are considered to

  20. Effect of fluoride solutions on the structure and hardness of plastic brackets.

    Science.gov (United States)

    Tziafa, Christina; Zinelis, Spiros; Makou, Margarita; Eliades, Theodore; Eliades, George

    2010-01-01

    To investigate the surface morphology, structure, molecular and elemental composition, and hardness of plastic brackets exposed to fluoride solutions. Two types of plastic brackets (Silkon Plus and SpiritMB) were exposed to three fluoride solutions 10 times for 1 minute each and then subjected to attenuated total relectance-Fournier transform infrared (ATR-FTIR) spectroscopy, scanning electron microscopy (SEM), x-ray energy dispersive microanalysis (EDS), and Vickers hardness (HV) testing. Hardness data were analyzed via two-way ANOVA and Tukey tests at the .05 level of significance with brackets and fluoride solution as predictors. ATR-FTIR spectroscopy showed that both bracket types consisted of polycarbonate. After treatment with acidulated phosphate fluoride, an increased contribution of -OH peaks at 3,200 cm-1(stretching [str]) and 1,640 cm-1 (a type of vibration [b]) was observed in both brackets. SEM revealed that the acidulated phosphate fluoride solution had a strong effect on the morphology and surface structure of the two brackets; a general deterioration with projections of the reinforcing fibers was observed. EDS showed evidence of aluminum, calcium, silicon, magnesium, and titanium, which could be attributed to the reinforcing glass fiber constituents. Hardness ranged in the order of 20 HV with no difference among the two bracket types and the three fluoride exposures. Repeated exposure of plastic brackets to fluoride solutions has a pronounced effect on their structure and morphology, but not their hardness. © 2010 BY QUINTESSENCE PUBLISHING CO, INC.

  1. Friction Forces during Sliding of Various Brackets for Malaligned Teeth: An In Vitro Study

    Science.gov (United States)

    Crincoli, Vito; Di Bisceglie, Maria Beatrice; Balsamo, Antonio; Serpico, Vitaliano; Chiatante, Francesco; Pappalettere, Carmine; Boccaccio, Antonio

    2013-01-01

    Aims. To measure the friction force generated during sliding mechanics with conventional, self-ligating (Damon 3 mx, Smart Clip, and Time 3) and low-friction (Synergy) brackets using different archwire diameters and ligating systems in the presence of apical and buccal malalignments of the canine. Methods. An experimental setup reproducing the right buccal segment of the maxillary arch was designed to measure the friction force generated at the bracket/wire and wire/ligature interfaces of different brackets. A complete factorial plan was drawn up and a three-way analysis of variance (ANOVA) was carried out to investigate whether the following factors affect the values of friction force: (i) degree of malalignment, (ii) diameter of the orthodontic wire, and (iii) bracket/ligature combination. Tukey post hoc test was also conducted to evaluate any statistically significant differences between the bracket/ligature combinations analyzed. Results. ANOVA showed that all the above factors affect the friction force values. The friction force released during sliding mechanics with conventional brackets is about 5-6times higher than that released with the other investigated brackets. A quasilinear increase of the frictional forces was observed for increasing amounts of apical and buccal malalignments. Conclusion. The Synergy bracket with silicone ligature placed around the inner tie-wings appears to yield the best performance. PMID:23533364

  2. Friction Forces during Sliding of Various Brackets for Malaligned Teeth: An In Vitro Study

    Directory of Open Access Journals (Sweden)

    Vito Crincoli

    2013-01-01

    Full Text Available Aims. To measure the friction force generated during sliding mechanics with conventional, self-ligating (Damon 3 mx, Smart Clip, and Time 3 and low-friction (Synergy brackets using different archwire diameters and ligating systems in the presence of apical and buccal malalignments of the canine. Methods. An experimental setup reproducing the right buccal segment of the maxillary arch was designed to measure the friction force generated at the bracket/wire and wire/ligature interfaces of different brackets. A complete factorial plan was drawn up and a three-way analysis of variance (ANOVA was carried out to investigate whether the following factors affect the values of friction force: (i degree of malalignment, (ii diameter of the orthodontic wire, and (iii bracket/ligature combination. Tukey post hoc test was also conducted to evaluate any statistically significant differences between the bracket/ligature combinations analyzed. Results. ANOVA showed that all the above factors affect the friction force values. The friction force released during sliding mechanics with conventional brackets is about 5-6times higher than that released with the other investigated brackets. A quasilinear increase of the frictional forces was observed for increasing amounts of apical and buccal malalignments. Conclusion. The Synergy bracket with silicone ligature placed around the inner tie-wings appears to yield the best performance.

  3. Shear bond strength of precoated orthodontic brackets: an in vivo study

    Directory of Open Access Journals (Sweden)

    Ali H Hassan

    2010-06-01

    Full Text Available Ali H HassanDepartment of Preventive Dental Sciences, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi ArabiaObjective: To evaluate the shear bond strength of precoated orthodontic brackets bonded with self-etching primer relative to that of noncoated conventionally-bonded brackets at two different time intervals.Methods: Twenty-one subjects were selected for randomized split-mouth bonding of two types of brackets to the maxillary arch. Half of the teeth had precoated brackets bonded using selfetching adhesive, and the other half had regular brackets bonded using Transbond XT adhesive. Nitinol wires were tied to the upper arch and were left until the time of debonding. The patients were randomly divided into two groups: one debonded after one hour and the other debonded two weeks after the initial wire placement. The shear bond strength was directly recorded from the patients’ mouths using an in vivo debonding device.Results: There were no significant differences in shear bond strength between the precoated and conventional groups or within each group at different time intervals. There were significant differences between anterior and posterior teeth in both the precoated and conventional groups. Conclusion: Pre-coated brackets bonded with self-etching adhesive have the same bonding strength as the conventionally bonded brackets.Keywords: shear bond, bonding, orthodontics, precoated, brackets, self-etching adhesive

  4. Caries outcomes after orthodontic treatment with fixed appliances: do lingual brackets make a difference?

    NARCIS (Netherlands)

    van der Veen, M.H.; Attin, R.; Schwestka-Polly, R.; Wiechmann, D.

    2010-01-01

    Orthodontic treatment with fixed appliances is considered a risk factor for the development of white spot caries lesions (WSL). Traditionally, brackets are bonded to the buccal surfaces. Lingual brackets are developing rapidly and have become more readily available. Buccal surfaces are considered to

  5. Loss of surface enamel after bracket debonding : An in-vivo and ex-vivo evaluation

    NARCIS (Netherlands)

    Pont, Huib Berghauser; Özcan, Mutlu; Bagis, Bora; Ren, Yijin

    2010-01-01

    INTRODUCTION: The objective of this study was to evaluate the surface enamel after bracket debonding and residual resin removal. METHODS: Thirty patients (female, 20; male, 10; mean age, 18.4 years) who completed orthodontic treatment with fixed appliances (Twin Brackets, 3M Unitek, Monrovia, Calif)

  6. Effects of green tea on the shear bond strength of orthodontic brackets after in-office vital bleaching.

    Science.gov (United States)

    Berger, Sandrine Bittencourt; Guiraldo, Ricardo Danil; Lopes, Murilo Baena; Oltramari-Navarro, Paula Vanessa; Fernandes, Thais Maria; Schwertner, Renata de Castro Alves; Ursi, Wagner José Silva

    2016-01-01

    The application of bleaching agents before placement of resin-bonded fixed appliances significantly, but temporarily, reduces bond strength to tooth structure. Antioxidants have been studied as a means to remove residual oxygen that compromises bonding to bleached enamel. This in vitro study evaluated whether green tea (GT) could restore the shear bond strength between bonded orthodontic brackets and bleached enamel. Six experimental groups were compared: group 1, no bleaching plus bracket bonding (positive control); group 2, bleaching with 35% hydrogen peroxide (HP) plus bracket bonding (negative control); group 3, 35% HP plus 10% sodium ascorbate (SA) plus bracket bonding; group 4, 35% HP plus 10% GT plus bracket bonding; group 5, no bleaching plus 10% SA plus bracket bonding; group 6, no bleaching plus 10% GT plus bracket bonding. Results suggested that GT, like SA, may be beneficial for bracket bonding immediately after bleaching.

  7. Nd:YAG Laser-aided ceramic brackets debonding: Effects on shear bond strength and enamel surface

    Energy Technology Data Exchange (ETDEWEB)

    Han Xianglong [State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041 (China); Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041 (China); Liu Xiaolin [Department of Orthodontics, Stomatology Hospital, Dalian University, Dalian 116021 (China); Bai Ding [State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041 (China); Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041 (China)], E-mail: baiding88@hotmail.com; Meng Yao; Huang Lan [Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041 (China)

    2008-11-15

    In order to evaluate the efficiency of Nd:YAG laser-aided ceramic brackets debonding technique, both ceramic brackets and metallic brackets were bonded with orthodontic adhesive to 30 freshly extracted premolars. The specimens were divided into three groups, 10 in each, according to the brackets employed and the debonding techniques used: (1) metallic brackets with shear debonding force, (2) ceramic brackets with shear debonding force, and (3) ceramic brackets with Nd:YAG laser irradiation. The result showed that laser irradiation could diminish shear bond strength (SBS) significantly and produce the most desired ARI scores. Moreover, scanning electron microscopy investigation displayed that laser-aided technique induced little enamel scratch or loss. It was concluded that Nd:YAG laser could facilitate the debonding of ceramic brackets and diminish the amount of remnant adhesive without damaging enamel structure.

  8. Nd:YAG Laser-aided ceramic brackets debonding: Effects on shear bond strength and enamel surface

    Science.gov (United States)

    Han, Xianglong; Liu, Xiaolin; Bai, Ding; Meng, Yao; Huang, Lan

    2008-11-01

    In order to evaluate the efficiency of Nd:YAG laser-aided ceramic brackets debonding technique, both ceramic brackets and metallic brackets were bonded with orthodontic adhesive to 30 freshly extracted premolars. The specimens were divided into three groups, 10 in each, according to the brackets employed and the debonding techniques used: (1) metallic brackets with shear debonding force, (2) ceramic brackets with shear debonding force, and (3) ceramic brackets with Nd:YAG laser irradiation. The result showed that laser irradiation could diminish shear bond strength (SBS) significantly and produce the most desired ARI scores. Moreover, scanning electron microscopy investigation displayed that laser-aided technique induced little enamel scratch or loss. It was concluded that Nd:YAG laser could facilitate the debonding of ceramic brackets and diminish the amount of remnant adhesive without damaging enamel structure.

  9. A comparative study on time efficiency management of self ligating brackets with conventional ligating brackets on orthodontic subjects in North Karnataka

    Directory of Open Access Journals (Sweden)

    Smita B. Patil

    2014-01-01

    Full Text Available Background: Self-Ligating brackets were originally designed with the intention to reduce the time needed to change wires compared with the use of wire ligatures. However, the advent of elastomeric ligatures meant that this perceived advantage was diminished. Objective: To compare aligning efficiency, rate of retraction and torque expression of Self Ligating bracket (SLB system with Conventional Pre adjusted Edgewise bracket (CLB system. Materials and Methods: Twelve patients were selected and divided into two groups treated with self ligating brackets (SLB, n=6 and conventional ligating brackets (CLB, n=6. The brackets used were 0.22 slot McLaughlin Bennet Trevesi (MBT prescription. Aligning was evaluated with 0.14 Niti followed by 19X25 Heat Activated Ni Ti and then 19X25 stainless steel wires for retraction within 4 months. The rate of retraction was evaluated per month and torque loss after space closure was also estimated. Results: Alignment Efficiency shows significant changes with SLB compared to CLB and also save more than 30% of chair side time during wire adjustments while rate of en masse retraction in SLB shows statistically non significance as compared to CLB system. In case of upper incisor changes when compared between two groups showed less torque loss in SLB than CLB although which was statistically no significant but % difference show SLB have better improvement result than CLB.

  10. Design of Engine Mount Bracket for a FSAE Car Using Finite Element Analysis

    Directory of Open Access Journals (Sweden)

    Jasvir Singh Dhillon

    2014-09-01

    Full Text Available Engine mounts have an important function of containing firmly the power-train components of a vehicle. Correct geometry and positioning of the mount brackets on the chassis ensures a good ride quality and performance. As an FSAE car intends to be a high performance vehicle, the brackets on the frame that support the engine undergo high static and dynamic stresses as well as huge amount of vibrations. Hence, dissipating the vibrational energy and keeping the stresses under a pre-determined level of safety should be achieved by careful designing and analysis of the mount brackets. Keeping this in mind the current paper discusses the modeling, Finite Element Analysis, Modal analysis and mass optimization of engine mount brackets for a FSAE car. As the brackets tend to undergo continuous vibrations and varying stresses, the fatigue strength and durability calculations also have been done to ensure engine safety.

  11. Enamel Surface Roughness after Debonding of Orthodontic Brackets and Various Clean-Up Techniques

    Directory of Open Access Journals (Sweden)

    Farzaneh Ahrari

    2013-01-01

    Full Text Available Objective: This study aimed to evaluate enamel roughness after adhesive removal using different burs and an Er:YAG laser.Materials and Methods: The buccal surfaces of forty human premolars were sealed by two layers of nail varnish, except for a circular area of 3 mm in diameter on the middle third. The enamel surfaces were initially subjected to profilometry analysis and four parameters of surface irregularity (Ra, Rq, Rt and Rz were recorded. Following bracket bonding and debonding, adhesive remnants were removed by tungsten carbide burs in low- or high- speed handpieces (group 1 and 2, respectively, an ultrafine diamond bur (group 3 or an Er:YAG laser (250 mJ, long pulse, 4 Hz (group 4, and surface roughness parameters were measured again. Then, the buccal surfaces were polished and the third profilometry measurements were performed.Results: The specimens that were cleaned with a low speed tungsten carbide bur showed no significant difference in surface irregularity between the different treatment stages (p>0.05. Surface roughness increased significantly after clean-up with the diamond bur and the Er:YAG laser (p<0.01. In comparison between groups, adhesive removal with tungsten carbide burs at slow- or high-speed handpieces produced the lowest, while enamel clean-up with the Er:YAG laser caused the highest values of roughness measurements (P<0.05.Conclusion: Under the study conditions, application of the ultrafine diamond bur or the Er:YAG laser caused irreversible enamel damage on tooth surface, and thus these methods could not be recommended for removing adhesive remnants after debonding of orthodontic brackets.

  12. Oral bacterial adhesion forces to biomaterial surfaces constituting the bracket-adhesive-enamel junction in orthodontic treatment.

    Science.gov (United States)

    Mei, Li; Busscher, Henk J; van der Mei, Henny C; Chen, Yangxi; de Vries, Joop; Ren, Yijin

    2009-08-01

    Bacterial adhesion to biomaterial surfaces constituting the bracket-adhesive-enamel junction represents a growing problem in orthodontics, because bacteria can adversely affect treatment by causing demineralization of the enamel surface around the brackets. It is important to know the forces with which bacteria adhere to the surfaces of these junction materials, as the strength of these forces will determine how easy it will be to remove the bacteria. We compared the adhesion forces of five initially colonizing and four cariogenic strains of bacteria to an orthodontic adhesive, stainless steel, and enamel, with and without a salivary conditioning film. Adhesion forces were determined using atomic force microscopy and a bacterial probe. In the absence of a salivary conditioning film, the strongest bacterial adhesion forces occurred to the adhesive surface (-2.9 to -6.9 nN), while adhesion forces to the enamel surfaces were lowest (-0.8 to -2.7 nN). In the presence of a salivary conditioning film, adhesion forces were reduced strongly, to less than 1 nN, and the differences between the various materials were reduced. Generally, however, initial colonizers of dental hard surfaces presented stronger adhesion forces to the different materials (-4.7 and -0.6 nN in the absence and presence of a salivary conditioning film, respectively) than cariogenic strains (-1.8 and -0.5 nN).

  13. Transformer real-time reliability model based on operating conditions

    Institute of Scientific and Technical Information of China (English)

    HE Jian; CHENG Lin; SUN Yuan-zhang

    2007-01-01

    Operational reliability evaluation theory reflects real-time reliability level of power system. The component failure rate varies with operating conditions. The impact of real-time operating conditions such as ambient temperature and transformer MVA (megavolt-ampere) loading on transformer insulation life is studied in this paper. The formula of transformer failure rate based on the winding hottest-spot temperature (HST) is given. Thus the real-time reliability model of transformer based on operating conditions is presented. The work is illustrated using the 1979 IEEE Reliability Test System. The changes of operating conditions are simulated by using hourly load curve and temperature curve, so the curves of real-time reliability indices are obtained by using operational reliability evaluation.

  14. Evaluating the Type of Light Transmittance in Mono Crystalline, Poly Crystalline and Sapphire Brackets- An Invitro Spectrofluorometer Study.

    Science.gov (United States)

    Mohamed, Jauhar P; Kommi, Pradeep Babu; Kumar, M Senthil; Hanumanth; Venkatesan; Aniruddh; Arvinth; Kumar, Arani Nanda

    2016-08-01

    Most of the patients seek orthodontic treatment to improve the smile, which improves the facial profile by means of fixed appliances i.e., brackets and wires. The brackets are of different types like stainless steel and ceramic. Ceramic brackets were considered as aesthetic appliance which was divided into mono-crystalline, polycrystalline and sapphire brackets. The light transmittance might influence the degree of curing adhesive material in mono crystalline, polycrystalline and sapphire brackets. The aim of the present study was to evaluate the translucency and intensity of three different aesthetic brackets (mono crystalline, poly crystalline and sapphire ceramic brackets) and to determine their influence on shear bond strength of the brackets. The adhesive remnant index was also measured after debonding of the brackets from the tooth surface. Twenty six samples each of monocrystalline, polycrystalline and sapphire brackets (total 78 ceramic brackets) were used for the study. The bracket samples were subjected to optical fluorescence test using spectrofluorometer to measure the intensity of the brackets. Seventy eight extracted premolar teeth were procured and divided into 3 groups. The brackets were then bonded to the tooth using Transbond XT (3M Unitek) light cure composite material and cured with new light cure unit (Light Emitting Diode) of wood pecker company (400-450nm) for 30 seconds, and these samples were subjected to shear bond strength test with Instron Universal Testing Machine (UNITEK-94100) with a load range between 0 to 100 KN with a maximum cross head speed of 0.5mm/min. ARI (Adhesive Remnant Index) scores were evaluated according to Artun and Bergland scoring system using stereomicroscope at 20x magnification. The light absorption values obtained from spectrofluorometeric study were 3300000-3500000 cps for group 1 (monocrystalline ceramic brackets), 6000000-6500000 cps for Group 2 (polycrystalline ceramic brackets) and 2700000 -3000000 cps for

  15. Evaluating the Type of Light Transmittance in Mono Crystalline, Poly Crystalline and Sapphire Brackets- An Invitro Spectrofluorometer Study

    Science.gov (United States)

    Kommi, Pradeep Babu; Kumar, M Senthil; Hanumanth; Venkatesan; Aniruddh; Arvinth; Kumar, Arani Nanda

    2016-01-01

    Introduction Most of the patients seek orthodontic treatment to improve the smile, which improves the facial profile by means of fixed appliances i.e., brackets and wires. The brackets are of different types like stainless steel and ceramic. Ceramic brackets were considered as aesthetic appliance which was divided into mono-crystalline, polycrystalline and sapphire brackets. The light transmittance might influence the degree of curing adhesive material in mono crystalline, polycrystalline and sapphire brackets. Aim The aim of the present study was to evaluate the translucency and intensity of three different aesthetic brackets (mono crystalline, poly crystalline and sapphire ceramic brackets) and to determine their influence on shear bond strength of the brackets. The adhesive remnant index was also measured after debonding of the brackets from the tooth surface. Materials and Methods Twenty six samples each of monocrystalline, polycrystalline and sapphire brackets (total 78 ceramic brackets) were used for the study. The bracket samples were subjected to optical fluorescence test using spectrofluorometer to measure the intensity of the brackets. Seventy eight extracted premolar teeth were procured and divided into 3 groups. The brackets were then bonded to the tooth using Transbond XT (3M Unitek) light cure composite material and cured with new light cure unit (Light Emitting Diode) of wood pecker company (400-450nm) for 30 seconds, and these samples were subjected to shear bond strength test with Instron Universal Testing Machine (UNITEK-94100) with a load range between 0 to 100 KN with a maximum cross head speed of 0.5mm/min. ARI (Adhesive Remnant Index) scores were evaluated according to Artun and Bergland scoring system using stereomicroscope at 20x magnification. Results The light absorption values obtained from spectrofluorometeric study were 3300000–3500000 cps for group 1 (monocrystalline ceramic brackets), 6000000–6500000 cps for Group 2

  16. Force Based Skill Learning for Robot Tasks in Contact Conditions

    Institute of Scientific and Technical Information of China (English)

    王琴; 梅志千; 张广立; 杨汝清

    2004-01-01

    To acquire human operation skill based on force sense, element contact form (ECF) is proposed to describe contact condition firstly. The skill is modeled as a sequence of discrete ECFs. Since different ECF has different force distribution, a support vector machine classifier is built to identify the contact conditions according to the force signal. Finally, the robot can obtain the skill from the human demonstration.

  17. Comparison of frictional resistance of esthetic and semi-esthetic self-ligating brackets

    Directory of Open Access Journals (Sweden)

    M S Kannan

    2015-01-01

    Full Text Available Aim: The frictional resistance encountered during sliding mechanics has been well established in the orthodontic literature, and it consists of complex interactions between the bracket, archwire, and method of ligation the claim of reduced friction with self-ligating brackets is often cited as a primary advantage over conventional brackets. This study was done to compare and evaluate the frictional forces generated between fully esthetic brackets and semi-aesthetic self-ligating brackets, which are of passive form and SEM (scanning electron microscope study of the Brackets after Frictional evaluation. Materials and Methods: Two types of self-ligating esthetic brackets, Damon clear (Ormco made of fully ceramic and Opal (Ultradent Products, USA and, Two types of self-ligating semi-esthetic brackets, Clarity SL (3M Unitek and Damon 3 (Ormco both of which are made of ceramic with metal slot. Arch wires with different dimensions and quality 17 × 25, 19 × 25 Titanium Molybdenum Alloy (TMA and 17 × 25, 19 × 25 stainless steel that came from plain strands of wire were used for frictional comparison test. The brackets used in this study had 0.022 × 0.028 inch slot. Results: The statistical tests showed significantly smaller amount of kinetic frictional forces is generated by Damon 3 (semi-esthetic self-ligating brackets. For each wire used, Damon 3 displayed significantly lower frictional forces (P ≤ 0.05 than any of the self-ligating system, followed by Opal (fully esthetic self-ligating brackets which generated smaller amount of frictional forces but relatively on the higher side when compared with Damon 3. Damon clear (fully esthetic self-ligating brackets generated the maximum amount of kinetic forces with all types of wire dimensions and properties when compared to the other three types of self-ligating system. Clarity SL (semi-esthetic self-ligating brackets generated smaller amount of frictional forces when compared with Damon clear and

  18. Performance and evaluation of desiccant based air conditioning system.

    Directory of Open Access Journals (Sweden)

    Gaurav S. Wani

    2014-12-01

    Full Text Available This Project work presents study and experimental analysis of Desiccant based air conditioning system.The main purpose of this project is to increase the efficency of air conditioning system.In the convenstional air conditioning system cooling coli has two load latent load and sensible load. Cooling has to cool the air and simultaneously to dehumidify it.It increases load on cooling coil and affects performance to the system. To increase the efficiency the air conditioning system desiccant materials are used at the inlet of the air conditioning test rig. Desiccant materials attract moisture based on differences in vapor pressure. Due to their enormous affinity to absorb water and considerable ability to hold water. Due to use of desiccant material load on the cooling coil reduces since moisture is absorbed by desiccant; cooling coil has to take only sensible load. Analysis is done using different desiccant materials and based on the observation, power consumption before and after desiccant is calculated. From this conclusion is made that desiccant material improves the efficiency of air conditioning test rig

  19. Vibration-based condition monitoring industrial, aerospace and automotive applications

    CERN Document Server

    Randall, Robert Bond

    2010-01-01

    ""Without doubt the best modern and up-to-date text on the topic, wirtten by one of the world leading experts in the field. Should be on the desk of any practitioner or researcher involved in the field of Machine Condition Monitoring"" Simon Braun, Israel Institute of Technology Explaining complex ideas in an easy to understand way, Vibration-based Condition Monitoring provides a comprehensive survey of the application of vibration analysis to the condition monitoring of machines. Reflecting the natural progression of these systems by presenting the fundamental material

  20. Condition-Based Maintenance using Sensor Arrays and Telematics

    CERN Document Server

    Palem, Gopalakrishna

    2013-01-01

    Emergence of uniquely addressable embeddable devices has raised the bar on Telematics capabilities. Though the technology itself is not new, its application has been quite limited until now. Sensor based telematics technologies generate volumes of data that are orders of magnitude larger than what operators have dealt with previously. Real-time big data computation capabilities have opened the flood gates for creating new predictive analytics capabilities into an otherwise simple data log systems, enabling real-time control and monitoring to take preventive action in case of any anomalies. Condition-based-maintenance, usage-based-insurance, smart metering and demand-based load generation etc. are some of the predictive analytics use cases for Telematics. This paper presents the approach of condition-based maintenance using real-time sensor monitoring, Telematics and predictive data analytics.

  1. Opening and closure forces of sliding mechanisms of different self-ligating brackets

    Directory of Open Access Journals (Sweden)

    Paola GANDINI

    2013-06-01

    Full Text Available Self-ligating brackets engage the wire by means of a slide mechanism. Forces that have to be applied to open and close the sliding mechanism of brackets are still unknown. Objective The aim of this study was to measure and compare the opening and closure forces of different self-ligating brackets. Material and Methods Three different stainless steel self-ligating brackets (Carriere LX, Ortho Organizers; F1000, Leone; Damon Q, Ormco were tested. For each different bracket, 20 maxillary right central incisors and 20 mandibular right central incisors were used. Opening and closure forces were measured using an Instron Universal Testing Machine. Statistical analysis was performed and ANOVA and Tukey tests were carried out. Results Opening forces were registered between 1.1 N and 5.6 N, whereas closure forces were recorded between 1.57 N and 4.87 N. Significant differences were detected among the different brackets and between the two prescriptions tested. Conclusion The knowledge of different opening and closure forces of self-ligating brackets can help the orthodontist in the clinical management of these devices.

  2. A comparative study of metal artifacts from common metal orthodontic brackets in magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kajan, Zahra Dalili; Alizadeh, Ahmad; Hemmaty, Yasmin Babael; Roushan, Zahra Atrkar; Khademi, Jalil [Guilan University of Medical Sciences, Rasht (Iran, Islamic Republic of)

    2015-09-15

    This study was performed to compare the metal artifacts from common metal orthodontic brackets in magnetic resonance imaging. A dry mandible with 12 intact premolars was prepared, and was scanned ten times with various types of brackets: American, 3M, Dentaurum, and Masel orthodontic brackets were used, together with either stainless steel (SS) or nickel titanium (NiTi) wires. Subsequently, three different sequences of coronal and axial images were obtained: spin-echo T1-weighted images, fast spin-echo T2-weighted images, and fluid-attenuated inversion recovery images. In each sequence, the two sequential axial and coronal images with the largest signal-void area were selected. The largest diameters of the signal voids in the direction of the X-, Y-, and Z-axes were then measured twice. Finally, the mean linear values associated with different orthodontic brackets were analyzed using one-way analysis of variation, and the results were compared using the independent t-test to assess whether the use of SS or NiTi wires had a significant effect on the images. Statistically significant differences were only observed along the Z-axis among the four different brands of orthodontic brackets with SS wires. A statistically significant difference was observed along all axes among the brackets with NiTi wires. A statistically significant difference was found only along the Z-axis between nickel-free and nickel-containing brackets. With respect to all axes, the 3M bracket was associated with smaller signal-void areas. Overall, the 3M and Dentaurum brackets with NiTi wires induced smaller artifacts along all axes than those with SS wires.

  3. Designing a future Conditions Database based on LHC experience

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00064378; Formica, Andrea; Gallas, Elizabeth; Lehmann Miotto, Giovanna; Pfeiffer, A.; Govi, G.

    2015-01-01

    We describe a proposal for a new Conditions Database infrastructure that ATLAS and CMS (or other) experiments could use starting on the timescale of Run 3. This proposal is based on the experience that both experiments accumulated during Run 1. We will present the identified relevant data flows for conditions data and underline the common use cases that lead to a joint effort for the development of a new system. Conditions data are needed in any scientific experiment. It includes any ancillary data associated with primary data taking such as detector configuration, state or calibration or the environment in which the detector is operating. In any non-trivial experiment, conditions data typically reside outside the primary data store for various reasons (size, complexity or availability) and are best accessed at the point of processing or analysis (including for Monte Carlo simulations). The ability of any experiment to produce correct and timely results depends on the complete and efficient availability of ne...

  4. Optimization of preventive condition-based tamping for railway tracks

    DEFF Research Database (Denmark)

    Wen, Min; Li, Rui; Salling, Kim Bang

    2016-01-01

    This work considers the scheduling of railway preventive condition-based tamping, which is the maintenance operation performed to restore the track irregularities to ensure both safety and comfort for passengers and freight. The problem is to determine when to perform the tamping on which section...

  5. A Wireless Distributed Condition Monitoring System Based on Bluetooth Technology

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Based on the discussion of bluetooth and network technology, this paper proposed an entire framework of a wireless distributed monitoring system by combining the characteristics of industry application. The feasibility of putting this kind of system in practice is discussed. The wireless distributed monitoring system can enhance the performance of condition monitoring more than the traditional one used now.

  6. Poisson brackets of mappings obtained as ( q,- p) reductions of lattice equations

    Science.gov (United States)

    Tran, Dinh T.; van der Kamp, Peter H.; Quispel, G. R. W.

    2016-11-01

    In this paper, we present Poisson brackets of certain classes of mappings obtained as general periodic reductions of integrable lattice equations. The Poisson brackets are derived from a Lagrangian, using the so-called Ostrogradsky transformation. The ( q,- p) reductions are ( p + q)-dimensional maps and explicit Poisson brackets for such reductions of the discrete KdV equation, the discrete Lotka-Volterra equation, and the discrete Liouville equation are included. Lax representations of these equations can be used to construct sufficiently many integrals for the reductions. As examples we show that the (3,-2) reductions of the integrable partial difference equations are Liouville integrable in their own right.

  7. Torque expression of 0.018 and 0.022 inch conventional brackets.

    Science.gov (United States)

    Sifakakis, Iosif; Pandis, Nikolaos; Makou, Margarita; Eliades, Theodore; Katsaros, Christos; Bourauel, Christoph

    2013-10-01

    The aim of this study was to assess the effect of the moments generated with low- and high-torque brackets. Four different bracket prescription-slot combinations of the same bracket type (Mini Diamond® Twin) were evaluated: high-torque 0.018 and 0.022 inch and low-torque 0.018 and 0.022 inch. These brackets were bonded on identical maxillary acrylic resin models with levelled and aligned teeth and each model was mounted on the orthodontic measurement and simulation system (OMSS). Ten specimens of 0.017 × 0.025 inch and ten 0.019 × 0.025 inch stainless steel archwires (ORMCO) were evaluated in the low- and high-torque 0.018 inch and 0.022 inch brackets, respectively. The wires were ligated with elastomerics into the brackets and each measurement was repeated once after religation. Two-way analysis of variance and t-test were conducted to compare the generated moments between wires at low- and high-torque brackets separately. The maximum moment generated by the 0.017 × 0.025 inch stainless steel archwire in the 0.018 inch brackets at +15 degrees ranged from 14.33 and 12.95 Nmm for the high- and low-torque brackets, respectively. The measured torque in the 0.022 inch brackets with the 0.019 × 0.025 inch stainless steel archwire was 9.32 and 6.48 Nmm, respectively. The recorded differences of maximum moments between the high- and low-torque series were statistically significant. High-torque brackets produced higher moments compared with low-torque brackets. Additionally, in both high- and low-torque configurations, the thicker 0.019 × 0.025 inch steel archwire in the 0.022 inch slot system generated lower moments in comparison with the 0.017 × 0.025 inch steel archwire in the 0.018 inch slot system.

  8. Maps Preserving Zero Lie Brackets on a Maximal Nilpotent Subalgebra of the Symplectic Algebra

    Institute of Scientific and Technical Information of China (English)

    Yan Xia ZHAO; Deng Yin WANG; Dong Fang JIA

    2011-01-01

    Let F be a field with char F ≠ 2,l a maximal nilpotent subalgebra of the symplectic algebra sp(2m,F).In this paper,we characterize linear maps of l which preserve zero Lie brackets in both directions.It is shown that for m ≥ 4,a map φ of l preserves zero Lie brackets in both directions if and only if φ = ψ cσToλαфdηf,where ψ c,σTo,λα,фd,ηf are the standard maps preserving zero Lie brackets in both directions.

  9. Study on Braking Sensation Based on Urban Working Conditions

    Directory of Open Access Journals (Sweden)

    Abi Lanie

    2017-01-01

    Full Text Available In this paper we researched the vehicle braking sense in three aspects of human, vehicle and environment and analysed their impacts on brake feeling. Through the real vehicle test we analysed the relationship among pedal force, pedal travel and deceleration. We used dynamometer test method to study the brake noise question. We designed a fixture which could imitate the suspension and made the test more close to the true level. Moreover we discussed how to establish the evaluation system of vehicle braking condition. Through real vehicle test of braking, we can test and record the brake system parameters in the braking process under urban working conditions. We recorded the brake frequency, the change of brake speed and brake disc temperature. Meanwhile, based on the analysis of braking condition, we put forward the index of brake load to reflect the city’s traffic conditions. Experiment show that the braking condition and brake feel are related, braking condition also provides theoretical support for the design of brake system.

  10. A comparative assessment of torque capabilities between lingual and labial brackets using three-dimension finite element%唇舌侧托槽转矩控制性能的有限元对比分析

    Institute of Scientific and Technical Information of China (English)

    黄思源; 周吉; 黄跃

    2016-01-01

    .The lingual bracket generated torque force decreased gradually from nickel-titanium(NiTi),Beta-titanium(TMA)to stainless steel(SS)under the same dimension.Conclusion:Torque moments of lin-gual and labial brackets both increases with the increase of torque angle in each operating condition.The lingual orthodontic brackets produce more torque force than labial brackets under the same torque angle.Torque performance of lingual bracket was affected by the material and dimension of the archwires.

  11. Predication of Crane Condition Parameters Based on SVM and AR

    Science.gov (United States)

    Xiuzhong, Xu; Xiong, Hu; Congxiao, Zhou

    2011-07-01

    Through statistic analysis of vibration signals of motor on the container crane hoisting mechanism in a port, the feature vectors with vibration are obtained. Through data preprocessing and training data, Training models of condition parameters based on support vector machine (SVM) are established. The testing data of condition monitoring parameters can be predicted by the training models. During training the models, the penalty parameter and kernel function of model are optimized by cross validation. In order to analysis the accurate of SVM model, autoregressive model is used to predict the trend of vibration. The research showed the predicted results of model using SVM are better than the results by autoregressive (AR) modeling.

  12. Establishment of computer aided bracket positioning system%计算机辅助托槽定位系统的建立

    Institute of Scientific and Technical Information of China (English)

    兰泽栋; 周丽淑

    2014-01-01

    目的 建立基于3D扫描、打印架构下的计算机辅助托槽定位系统(computer aided bracket placement system,CABPS).方法 通过3D扫描获取3D数字化牙颌模型,利用正畸计算机辅助设计(orthodontics computer aided design,Ortho CAD)技术对数字化模型进行牙齿分离,按照正常咬合六项标准进行牙齿排列;基于临床冠中心法和托槽槽沟平直化原则做计算机辅助托槽定位,计算机对已附带托槽定位标尺的牙齿进行原态模型复位,3D打印,压制托槽定位模板,在模拟(牙合)架上进行托槽间接粘接后模拟矫治,验证矫治效果.结果 在3D扫描、打印架构下,基于Ortho CAD技术建立了CABPS.结论 CABPS可提高托槽定位精度,实现了矫治效果可预期、可视.%Objective The aim of this study was to present a computer aided orthodontic bracket positioning system,which was based on 3D scanning,3D printing and orthodontic computer aided design (Ortho CAD).Methods Digital dental model was obtained by 3D scanning.By the aid of Ortho CAD,digital teeth were separated from virtual model and realigned based on the rule of Andrew's Six Keys.The positions of orthodontic brackets were calculated on individual digital tooth in the center of clinical crown with the diriction according to slot straighthening principle.The virtual teeth were then aligned back to their original position,and created a new dental model with bracket positioning marker by 3D printer.Based on the new dental model,an individual stent was produced for indirect bonding.To test the accuracy of the system,a simulated orthodontic treatment was performed through Typodont procedures.Results the Computer Aided Bracket Positioning System (CABPS) was established based on Ortho CAD,3D scanning and 3D printing.Conclusions CABPS could increase the accuracy of bracket placement and predictability of orthodontic treatment.

  13. Condition-based Human Reliability Assessment for digitalized control room

    Energy Technology Data Exchange (ETDEWEB)

    Kang, H. G.; Jang, S. C.; Eom, H. S.; Ha, J. J

    2005-04-01

    In safety-critical systems, the generation failure of an actuation signal is caused by the concurrent failures of the automated systems and an operator action. These two sources of safety signals are complicatedly correlated. The failures of sensors or automated systems will cause a lack of necessary information for a human operator and result in error-forcing contexts such as the loss of corresponding alarms and indications. In the conventional analysis, the Human Error Probabilities (HEP) are estimated based on the assumption of 'normal condition of indications and alarms'. In order to construct a more realistic signal-generation failure model, we have to consider more complicated conditions in a more realistic manner. In this study, we performed two kinds of investigation for addressing this issue. We performed the analytic calculations for estimating the effect of sensors failures on the system unavailability and plant risk. For the single-parameter safety signals, the analysis result reveals that the quantification of the HEP should be performed by focusing on the 'no alarm from the automatic system and corresponding indications unavailable' situation. This study also proposes a Condition-Based Human Reliability Assessment (CBHRA) method in order to address these complicated conditions in a practical way. We apply the CBHRA method to the manual actuation of the safety features such as a reactor trip and auxiliary feedwater actuation in Korean Standard Nuclear Power Plants. In the case of conventional single HEP method, it is very hard to consider the multiple HE conditions. The merit of CBHRA is clearly shown in the application to the AFAS generation where no dominating HE condition exits. In this case, even if the HE conditions are carefully investigated, the single HEP method cannot accommodate the multiple conditions in a fault tree. On the other hand, the application result of the reactor trip in SLOCA shows that if there is a

  14. Clinical assessment of demineralization and remineralization surrounding orthodontic brackets with FluoreCam

    Directory of Open Access Journals (Sweden)

    Bora Korkut

    2017-04-01

    Conclusions: This study demonstrated that demineralization is measurable around orthodontic brackets and the demineralization can be completely inhibited and/or reversed by the use of commercially available remineralization products.

  15. Laser brackets debonding: Tm:YAP, Nd:YAG, and GaAs diode lasers evaluation

    Science.gov (United States)

    Dostálová, Tat'jana; Jelínková, Helena; Šulc, Jan; Koranda, Petr; Němec, Michal; Ivanov, Ilja; Miyagi, Mitsunobu; Iwai, Katsumasa

    2009-02-01

    The study demonstrates the possibility of using laser radiation for the ceramic bracket removing. Three laser radiations were examined for this effect and the removing possibility and velocity together with enamel and root damage were investigated. A diode pumped Tm:YAP microchip laser generating a wavelength 1.9 μm, diode pumped Nd:YAG laser with 1.44 μm wavelength, GaAs diode with 0.808 μm were used for the debonding purpose. The measurement of transmission and absorption of the basic element - bracket, adhesive resin, and enamel was also made with the goal to explain the source of the heat and bracket debonding. The explanation of the debonding effect is also presented. From the results it is possible to conclude that continuously running diode pumped microchip Tm:YAP laser having output power 1W can be a good candidate for ceramic bracket debonding procedure.

  16. Laser brackets debonding: Tm:YAP and ClarityTM SL self-ligating appliance system

    Science.gov (United States)

    Dostálová, Tatjana; Jelínková, Helena; Šulc, Jan; Koranda, Petr; Němec, Michal; Jelínek, Michal; Fibrich, Martin; Michalik, Pavel; Miyagi, Mitsunobu

    2010-02-01

    The study demonstrates the possibility of using Tm:YAP laser radiation for the removing ceramic brackets. The amount of enamel loss and residual resin on teeth has been evaluated. A diode-pumped Tm:YAP microchip laser generating at wavelength 1.9 μm was used for the debonding process. The transmission and absorption measurement of the basic elements - bracket, adhesive resin, and enamel was analyzed to explain the source of the heat and bracket debonding. Quantitative measurements are made for visualizing enamel surface before and after a self-ligating bonding technique. Temperature rise observation during the debonding procedure - from 0.5 to 2 W power - has improved the accuracy of assessment. The results were evaluated by CCD camera and scanning electron microscope. From the measurements it is possible to conclude that continuously running small diode pumped Tm:YAP microchip laser having output power 1W can remove the ceramic bracket without enamel iatrogenic damage.

  17. A Realization of Hom-Lie Algebras by Iso-Deformed Commutator Bracket

    OpenAIRE

    Xiuxian Li

    2013-01-01

    We construct classical Iso-Lie and Iso-Hom-Lie algebras in $gl(V)$ by twisted commutator bracket through Iso-deformation. We prove that they are simple. Their Iso-automorphisms and isotopies are also presented.

  18. Comparative Evaluation of Two Remineralizing Agents on Enamel around Orthodontic Brackets: An in vitro Study

    Directory of Open Access Journals (Sweden)

    K M Soumya

    2014-01-01

    Conclusion: GC Tooth Mousse Plus (ACP-CPPF showed better efficiency in reducing the demineralization and enhancing the remineralization around the orthodontic brackets and have maximum benefit compared to GC Tooth Mousse with good patient compliance.

  19. [Adsorption dynamics and breakthrough characteristics based on the fluidization condition].

    Science.gov (United States)

    Wang, Jun; Wang, Yao; Huang, Xing; Yuan, Yi-Long; Chen, Rui-Hui; Zhou, Hang; Zhou, Dan-Dan

    2014-02-01

    Few studies on the adsorption dynamics and breakthrough characteristics based on the fluidization condition have been reported. In a fluidized bed adsorption reactor with phenol as the adsorbate and granular activated carbon as the adsorbent, the adsorption efficiency, adsorption dynamic characteristics, adsorption breakthrough curves and adsorption capacities were studied and compared with those of a fixed bed operated under the same conditions. The results showed that the adsorption efficiencies exceeded 93% in 5 min in both the fluidized conditions and fixed conditions at the superficial velocities of 8 mm x s(-1) and 13 mm x s(-1). Meanwhile, the above adsorption reactions fitted to Pseudo-second-order with linear correlation coefficients greater than 0.999. The adsorption capacity of fluidized conditions was 8.77 mg x g(-1) and 24.70 mg x g(-1) at the superficial velocities of 6 mm x s(-1) and 8 mm x s(-1). Generally, the fluidized bed reactor showed a higher adsorption efficiency and greater adsorption capacity than the fixed bed reactor.

  20. Shear Bond Strength of DentStat(trademark) for Bracket Bonding to Gold, Ceramic, and Enamel

    Science.gov (United States)

    2012-12-21

    i Shear bond strength of DentStatTM for bracket bonding to gold, ceramic, and enamel . A THESIS Presented to the Faculty of Uniform...in the thesis manuscript entitled: ’Shear Bond Strength of DentStatTM for Bracket Bonding to Gold, Ceramic, and Enamel ’ is appropriately...Ceramic, and Enamel ’ 7. Intended publication/meeting: June 2013 8. "Required by" date: 1 July 2013 9. Date of submission for USU approval: 6 June

  1. Biocompatibility of nanosilver-coated orthodontic brackets: an in vivo study

    Directory of Open Access Journals (Sweden)

    Gamze Metin-Gürsoy

    2016-12-01

    Full Text Available Abstract Background Nanosilver particles of which antibacterial and antifungal properties have been shown in various in vitro and in vivo studies are used in many medical and dental fields for the prevention of infection. In this study, it is intended to evaluate the biocompatibility of nanosilver-coated brackets. Methods Nanosilver coating process was applied to the standard orthodontic brackets by a physical vapor deposition system. Brackets were coated with nanosilver particles of 1 μ thickness. A total of 12 Wistar Albino rats were included in the study (six and control (six groups. For the study and control groups, four nanosilver-coated and four standard brackets were aseptically implanted subcutaneously in the dorsal region of each rat. The brackets were removed with the surrounding tissues on days 7, 14, 30, and 60. The specimens were evaluated for inflammatory response. Results No significant difference was found in terms of tissue reaction between the study and control groups. On day 7, randomly distributed brown-black granules were seen in the granulation tissue adjacent to the bracket in the study group. These foreign particles continued along the bracket cavity in a few samples, but the inflammatory response was insignificant between the groups. Mast cell count was found to be significantly smaller only on day 7 in the study group than in the control group. Conclusions Nanosilver-coated orthodontic brackets were found to be similar with the standard type concerning inflammation. Further researches are needed with regard to the assessment of the brown-black granules, especially on the deposition of the vessel walls.

  2. Evaluation of bond strength of brackets using various indirect bonding techniques

    OpenAIRE

    Piyush Bolya; Chandresh Shukla; Gunjan Tiwari; Sourabh Bhatt; Saurabh Rathore; Akbar Ali

    2017-01-01

    Introduction: Accurate bracket placement has been always an area of interest for all orthodontists. Different types of adhesives for indirect bonding techniques have been introduced recently. However, there is limited information regarding bond strength with these new materials. The aim of this study is to compare and evaluate the bond strength in various indirect bonding techniques when using different primers and adhesives. Materials and Methods: In this in vitro investigation, brackets wer...

  3. Evaluation of force released by deflection of orthodontic wires in conventional and self-ligating brackets

    Science.gov (United States)

    Higa, Rodrigo Hitoshi; Semenara, Nayara Thiago; Henriques, José Fernando Castanha; Janson, Guilherme; Sathler, Renata; Fernandes, Thais Maria Freire

    2016-01-01

    ABSTRACT Introduction: The aim of the study was to evaluate deflection forces of rectangular orthodontic wires in conventional (MorelliTM), active (In-Ovation RTM) and passive (Damon 3MXTM) self-ligating brackets. Material and Methods: Two brands of stainless steel and nickel-titanium (NiTi) wires (MorelliTM and GACTM), in addition to OrmcoTM copper-nickel-titanium wires were used. Specimens were assembled in a clinical simulation device especially designed for this study and tested in an Instron universal testing machine. For the testing procedures, an acrylic structure representative of the maxillary right central incisor was lingually moved in activations of 0 to 1 mm, with readings of the force released by deflection in unloading of 0.5, 0.8 and 1 mm at a constant speed of 2 mm/min. Inter-bracket forces with stainless steel, NiTi and CuNiTi were individually compared by two-way ANOVA, followed by Tukey’s tests. Results: Results showed that there were lower forces in conventional brackets, followed by active and passive self-ligating brackets. Within the brands, only for NiTi wires, the MorelliTM brand presented higher forces than GACTM wires. Conclusions: Bracket systems provide different degrees of deflection force, with self-ligating brackets showing the highest forces. PMID:28125144

  4. Comparison of shear bond strengths of ceramic brackets after different time lags between lasing and debonding.

    Science.gov (United States)

    Tozlu, Murat; Oztoprak, Mehmet Oguz; Arun, Tülin

    2012-11-01

    Laser use is effective in the debonding of ceramic brackets. However, a standardization of the laser debonding techniques used has not yet been implemented. The purpose of this study was to evaluate the effect of the time lag elapsed between lasing and shearing on debonding of ceramic brackets. One hundred polycrystalline ceramic brackets were placed on human premolar teeth, which were randomly divided into five groups of 20. One group was assigned as the control. The Er-YAG laser was applied on each bracket in four experimental groups at 5 W for 6 s with the scanning method. Debonding was performed 1 s, 18 s, 30 s, or 60 s after laser exposure. Shear bond strengths and adhesive remnant index scores were measured. Statistically significant difference was observed between the control and experimental groups when the data for the shear bond strengths was considered (p  0.05). Debonding ceramic brackets after 18 s when lased 6 s using an Er-YAG laser with the scanning method is safe and also suitable for clinical use since three brackets can be debonded at a time in succession.

  5. Evaluation of force released by deflection of orthodontic wires in conventional and self-ligating brackets

    Directory of Open Access Journals (Sweden)

    Rodrigo Hitoshi Higa

    Full Text Available ABSTRACT Introduction: The aim of the study was to evaluate deflection forces of rectangular orthodontic wires in conventional (MorelliTM, active (In-Ovation RTM and passive (Damon 3MXTM self-ligating brackets. Material and Methods: Two brands of stainless steel and nickel-titanium (NiTi wires (MorelliTM and GACTM, in addition to OrmcoTM copper-nickel-titanium wires were used. Specimens were assembled in a clinical simulation device especially designed for this study and tested in an Instron universal testing machine. For the testing procedures, an acrylic structure representative of the maxillary right central incisor was lingually moved in activations of 0 to 1 mm, with readings of the force released by deflection in unloading of 0.5, 0.8 and 1 mm at a constant speed of 2 mm/min. Inter-bracket forces with stainless steel, NiTi and CuNiTi were individually compared by two-way ANOVA, followed by Tukey’s tests. Results: Results showed that there were lower forces in conventional brackets, followed by active and passive self-ligating brackets. Within the brands, only for NiTi wires, the MorelliTM brand presented higher forces than GACTM wires. Conclusions: Bracket systems provide different degrees of deflection force, with self-ligating brackets showing the highest forces.

  6. Comparison of Shear Bond Strength of RMGI and Composite Resin for Orthodontic Bracket Bonding.

    Science.gov (United States)

    Yassaei, Soghra; Davari, Abdolrahim; Goldani Moghadam, Mahjobeh; Kamaei, Ahmad

    2014-05-01

    The aim of this study was to compare the shear bond strength (SBS) of resin modified glass ionomer (RMGI) and composite resin for bonding metal and ceramic brackets. Eighty-eight human premolars extracted for orthodontic purposes were divided into 4 groups (n=22). In groups 1 and 2, 22 metal and ceramic brackets were bonded using composite resin (Transbond XT), respectively. Twenty-two metal and ceramic brackets in groups 3 and 4, respectively were bonded using RMGI (Fuji Ortho LC, Japan). After photo polymerization, the teeth were stored in water and thermocycled (500 cycles between 5° and 55°). The SBS value of each sample was determined using a Universal Testing Machine. The amount of residual adhesive remaining on each tooth was evaluated under a stereomicroscope. Statistical analyses were done using two-way ANOVA. RMGI bonded brackets had significantly lower SBS value compared to composite resin bonded groups. No statistically significant difference was observed between metal and ceramic brackets bonded with either the RMGI or composite resin. The comparison of the adhesive remnant index (ARI) scores between the groups indicated that the bracket failure mode was significantly different among groups (Pcomposite resin. RMGIs have significantly lower SBS compared to composite resin for orthodontic bonding purposes; however the provided SBS is still within the clinically acceptable range.

  7. Effect of Argon Laser on Enamel Demineralization around Orthodontic Brackets: An In Vitro Study.

    Directory of Open Access Journals (Sweden)

    Amirfarhang Miresmaeili

    2014-08-01

    Full Text Available This study was designed to evaluate the effect of argon laser irradiation on development and progress of enamel demineralization around orthodontic brackets.Fifty caries-free, intact human premolars were randomly assigned to one of the following five equal groups: Groups 1 (control and 2: The brackets were bonded using conventional halogen light for 40s and argon laser for 10s, respectively. Teeth in group 3 were lased with argon laser for 10s before bracket bonding with halogen light. Group 4 was the same as group 3 except that brackets were also bonded with argon laser. In group 5 samples were bonded conventionally, immersed in an artificial caries solution for two days and then irradiated for 10s with argon laser. All samples were subjected to demineralization by artificial caries solution for 10 days. After bracket removal, samples were buccolingually sectioned and evaluated by polarized light microscopy. Decalcified lesion depth in each section was measured by a trained examiner in a blind fashion. Data were analyzed in SPSS 14 using one-way ANOVA and Tukey's HSD post hoc test.The control group showed the greatest mean lesion depth while group 5 revealed the lowest. The laser-treated groups had significantly lower mean lesion depth compared with the control group (P<0.05 except for group 4 (P=0.192.Argon laser irradiation for 10s before or during bracket bonding can increase caries resistance of intact and demineralized enamel.

  8. In vitro evaluation of microleakage under orthodontic brackets bonded with different adhesive systems.

    Science.gov (United States)

    Atash, Ramin; Fneiche, Ali; Cetik, Sibel; Bahrami, Babak; Balon-Perin, Alain; Orellana, Maria; Glineur, Régine

    2017-01-01

    Adhesives systems have a drawback when utilized for bonding orthodontic brackets: they shrink during photopolymerization creating microleakage. The aim of this study was to assess the stability of different orthodontic adhesives around brackets and enamel. Sixty noncarious mandibular premolars extracted for orthodontic reasons were randomly divided into six groups of adhesives used for bonding brackets to dental enamel: NeoBond(®) Light Cure Adhesive Kit, Transbond™ Plus Self-Etching, Victory V-Slot APC PLUS(®) + Transbond™ MIP, Rely-A-Bond(®) Kit, Light Cure Orthodontic Adhesive Kit (OptiBond(®)), and Transbond™ MIP. Following bonding, all teeth underwent 2500 cycles of thermal cycling in baths ranging from 5°C to 55°C before being immersed in 2% methylene blue for 24 h. All samples were examined under a binocular microscope to assess the degree of microleakage at the "bracket-adhesive" and "adhesive-enamel" interfaces in the gingival and occlusal regions of the bracket. A significant difference was found at the "occlusal bracket-adhesive" interface. The highest microleakage values were found in the occlusal region, although no significant. Microleakage was observed in all groups. Group 2 had the highest microleakage values whereas Group 6 had the lowest values.

  9. Mechanical and topographic evaluation of esthetic brackets and its relation to frictional resistance

    Directory of Open Access Journals (Sweden)

    Vikram Pai

    2013-01-01

    Full Text Available Introduction: The purpose of this in-vitro study was to evaluate the frictional characteristics of conventional ceramic versus metal insert ceramic brackets in combination with stainless steel and Teflon-coated stainless steel archwires. Materials and Methods: Twenty brackets each, of ceramic and metal insert ceramic Maxillary canine preadjusted edgewise brackets 0.022 × 0.028 in slot and 20 archwires, each of stainless steel and Teflon-coated stainless steel (0.019 × 0.025 in were tested for frictional resistance. Friction was evaluated in a simulated Tidy′s design apparatus on universal testing machine. The kinetic friction data were analyzed using Student′s ′t′ test. The effects of surface characteristics on frictional resistance were qualitatively assessed using scanning electron microscope. Results: Metal insert ceramic brackets generated significantly lower kinetic frictional resistance than the conventional ceramic brackets with Teflon-coated stainless steel archwires (P < 0.001 as well as stainless steel archwires (P < 0.05. Conclusion: Metal insert ceramic bracket with stainless steel archwire is the best possible combination among the materials studied because it generated the least frictional resistance during simulated tooth movement.

  10. Influence of ligation method on friction resistance of lingual brackets with different second-order angulations: an in vitro study

    Science.gov (United States)

    Pereira, Graziane Olímpio; Gimenez, Carla Maria Melleiro; Prieto, Lucas; Prieto, Marcos Gabriel do Lago; Basting, Roberta Tarkany

    2016-01-01

    ABSTRACT Objective: To evaluate stainless steel archwire static friction in active and passive self-ligating lingual and conventional brackets with second-order angulations. Methods: Two conventional lingual brackets for canines (STb light/Ormco; PSWb/Tecnident), and two self-ligating brackets, one active (In-Ovation L/GAC) and the other passive (3D/ Forestadent), were evaluated. A stainless steel archwire was used at 0°, 3° and 5° angulations. Metal ligatures, conventional elastic ligatures, and low friction elastic ligatures were also tested. A universal testing machine applied friction between brackets and wires, simulating sliding mechanics, to produce 2-mm sliding at 3 mm/minute speed. Results: Two-way analysis of variance demonstrated a significant effect of the interaction between brackets and angulations (p < 0.001). Tukey test indicated that the highest frictional resistance values were observed at 5° angulation for In-Ovation L, PSWb bracket with non conventional ligature, and STb bracket with metal ligature. As for 3D, PSWb with conventional or metal ligatures, and STb brackets with non conventional ligature, showed significantly lower static frictional resistance with 0° angulation. At 0° angulation, STb brackets with metal ties, In-Ovation L brackets and 3D brackets had the lowest frictional resistance. Conclusions: As the angulation increased from 0° to 3°, static friction resistance increased. When angulation increased from 3° to 5°, static friction resistance increased or remained the same. Self-ligating 3D and In-Ovation L brackets, as well as conventional STb brackets, seem to be the best option when sliding mechanics is used to perform lingual orthodontic treatment. PMID:27653262

  11. Reverse time migration based on normalized wavefield decomposition imaging condition

    Institute of Scientific and Technical Information of China (English)

    YU Jianglong; HAN Liguo; ZHOU Yan; ZHANG Yongsheng

    2016-01-01

    With the increasing complexity of prospecting objectives,reverse time migration (RTM)has attracted more and more attention due to its outstanding imaging quality.RTMis based on two-way wave equation,so it can avoid the limits of angle in traditional one-way wave equation migration,image reverse branch,prism waves and multi-reflected wave precisely and obtain accurate dynamic information.However,the huge demands for storage and computation as well as low frequency noises restrict its wide application.The normalized cross-correlation ima-ging conditions based on wave field decomposition are derived from traditional cross-correlation imaging condition, and it can eliminate the low-frequency noises effectively and improve the imaging resolution.The practical proce-dure includes separating source and receiver wave field into one-way components respectively,and conducting cross-correlation imaging condition to the post-separated wave field.In this way,the resolution and precision of the imaging result will be promoted greatly.

  12. Controlled cooling of an electronic system based on projected conditions

    Science.gov (United States)

    David, Milnes P.; Iyengar, Madhusudan K.; Schmidt, Roger R.

    2016-05-17

    Energy efficient control of a cooling system cooling an electronic system is provided based, in part, on projected conditions. The control includes automatically determining an adjusted control setting(s) for an adjustable cooling component(s) of the cooling system. The automatically determining is based, at least in part, on projected power consumed by the electronic system at a future time and projected temperature at the future time of a heat sink to which heat extracted is rejected. The automatically determining operates to reduce power consumption of the cooling system and/or the electronic system while ensuring that at least one targeted temperature associated with the cooling system or the electronic system is within a desired range. The automatically determining may be based, at least in part, on an experimentally obtained model(s) relating the targeted temperature and power consumption of the adjustable cooling component(s) of the cooling system.

  13. Controlled cooling of an electronic system based on projected conditions

    Energy Technology Data Exchange (ETDEWEB)

    David, Milnes P.; Iyengar, Madhusudan K.; Schmidt, Roger R.

    2015-08-18

    Energy efficient control of a cooling system cooling an electronic system is provided based, in part, on projected conditions. The control includes automatically determining an adjusted control setting(s) for an adjustable cooling component(s) of the cooling system. The automatically determining is based, at least in part, on projected power consumed by the electronic system at a future time and projected temperature at the future time of a heat sink to which heat extracted is rejected. The automatically determining operates to reduce power consumption of the cooling system and/or the electronic system while ensuring that at least one targeted temperature associated with the cooling system or the electronic system is within a desired range. The automatically determining may be based, at least in part, on an experimentally obtained model(s) relating the targeted temperature and power consumption of the adjustable cooling component(s) of the cooling system.

  14. Bridge Condition Assessment based on Vibration Responses of Passenger Vehicle

    Science.gov (United States)

    Miyamoto, Ayaho; Yabe, Akito

    2011-07-01

    In this paper, we propose a new method of assessing the condition of existing short- and medium-span reinforced/prestressed concrete bridges based on vibration monitoring data obtained from a public bus. This paper not only describes details of a prototype monitoring system that uses information technology and sensors capable of providing more accurate knowledge of bridge performance than conventional ways but also shows a few specific examples of bridge condition assessment based on vehicle vibrations measured by using an in-service public bus equipped with vibration measurement instrumentation. This paper also describes a sensitivity analysis of deteriorating bridges based on simulation of the acceleration response of buses conducted by the "substructure method" employing a finite element model to verify the above bridge performance results. The main conclusions obtained in this study can be summarized as follows: (1) Because the vibration responses of passenger vehicles, such as buses, have a good linear relationship with the vibration responses of the target bridges, the proposed system can be used as a practical monitoring system for bridge condition assessment. (2) The results of sensitivity analysis performed by the substructure method show that bus vibration responses are useful for evaluating target bridge performance. (3) The proposed method was applied to a network of real bridges in a local area to evaluate its effectiveness. The results indicate that the proposed method can be used to prioritize the repair/strengthening works of existing bridges based on various vibration information in order to help bridge administrators establish rational maintenance strategies.

  15. Measuring intracellular redox conditions using GFP-based sensors

    DEFF Research Database (Denmark)

    Björnberg, Olof; Ostergaard, Henrik; Winther, Jakob R

    2006-01-01

    Recent years have seen the development of methods for analyzing the redox conditions in specific compartments in living cells. These methods are based on genetically encoded sensors comprising variants of Green Fluorescent Protein in which vicinal cysteine residues have been introduced at solvent......-exposed positions. Several mutant forms have been identified in which formation of a disulfide bond between these cysteine residues results in changes of their fluorescence properties. The redox sensors have been characterized biochemically and found to behave differently, both spectroscopically and in terms...... of redox properties. As genetically encoded sensors they can be expressed in living cells and used for analysis of intracellular redox conditions; however, which parameters are measured depends on how the sensors interact with various cellular redox components. Results of both biochemical and cell...

  16. Model-based condition monitoring for lithium-ion batteries

    Science.gov (United States)

    Kim, Taesic; Wang, Yebin; Fang, Huazhen; Sahinoglu, Zafer; Wada, Toshihiro; Hara, Satoshi; Qiao, Wei

    2015-11-01

    Condition monitoring for batteries involves tracking changes in physical parameters and operational states such as state of health (SOH) and state of charge (SOC), and is fundamentally important for building high-performance and safety-critical battery systems. A model-based condition monitoring strategy is developed in this paper for Lithium-ion batteries on the basis of an electrical circuit model incorporating hysteresis effect. It systematically integrates 1) a fast upper-triangular and diagonal recursive least squares algorithm for parameter identification of the battery model, 2) a smooth variable structure filter for the SOC estimation, and 3) a recursive total least squares algorithm for estimating the maximum capacity, which indicates the SOH. The proposed solution enjoys advantages including high accuracy, low computational cost, and simple implementation, and therefore is suitable for deployment and use in real-time embedded battery management systems (BMSs). Simulations and experiments validate effectiveness of the proposed strategy.

  17. Effect of moisture, saliva, and blood contamination on the shear bond strength of brackets bonded with a conventional bonding system and self-etched bonding system

    Science.gov (United States)

    Prasad, Mandava; Mohamed, Shamil; Nayak, Krishna; Shetty, Sharath Kumar; Talapaneni, Ashok Kumar

    2014-01-01

    Background: The success of bonding brackets to enamel with resin bonding systems is negatively affected by contamination with oral fluids such as blood and saliva. The new self-etch primer systems combine conditioning and priming agents into a single application, making the procedure more cost effective. Objective: The purpose of the study was to investigate the effect of moisture, saliva and blood contamination on shear bond strength of orthodontic brackets bonded with conventional bonding system and self-etch bonding system. Materials and Methods: Each system was examined under four enamel surface conditions (dry, water, saliva, and blood), and 80 human teeth were divided into two groups with four subgroups each of 10 according to enamel surface condition. Group 1 used conventional bonding system and Group 2 used self-etched bonding system. Subgroups 1a and 2a under dry enamel surface conditions; Subgroups 1b and 2b under moist enamel surface condition; Subgroups 3a and 3b under saliva enamel surface condition and Subgroup 4a and 4b under blood enamel surface condition. Brackets were bonded, and all the samples were then submitted to a shear bond test with a universal testing machine with a cross head speed of 1mm/sec. Results: The results showed that the contamination reduced the shear bond strength of all groups. In self-etch bonding system water and saliva had significantly higher bond strength when compared to other groups. Conclusion: It was concluded that the blood contamination showed lowest bond strength from both bonding systems. Self-etch bonding system resulted in higher bond strength than conventional bonding system under all conditions except the dry enamel surface. PMID:24678210

  18. Prediction of Surface Roughness Based on Machining Condition and Tool Condition in Boring EN31 Steel

    Directory of Open Access Journals (Sweden)

    P. Mohanaraman

    2016-04-01

    Full Text Available Prediction of Surface roughness plays a vital role in manufacturing process. In manufacturing industries, productions of metallic materials require high surface finish in various components. In the present work, the effect of spindle speed, feed rate, depth of cut and flank wear of the tool on the surface roughness has been studied. Carbide tipped insert was used for boring operation. Experiments were conducted in CNC lathe. The experimental setup was prepared with sixteen levels of cutting parameters and was conducted with two tool tip conditions in dry machining. A piezoelectric accelerometer was used to measure the vibrational signals while machining. The data acquisition card which connected between accelerometer and lab-view software to record the signals. Simple linear and least median regression models were used for prediction of surface roughness. The models were developed by weka analysis software. The best suitable regression model is implemented based on maximum correlation coefficient and the minimum error values.

  19. A new self-curing resin-modified glass-ionomer cement for the direct bonding of orthodontic brackets in vivo.

    Science.gov (United States)

    Fricker, J P

    1998-04-01

    A new self-curing (chemically cured) resin-modified glass-ionomer cement, Fuji Ortho (GC International), is based on the technology of hybrid glass-ionomer restorative materials and features chemical adhesion to tooth structure and long-term fluoride release. This article describes a 12-month clinical evaluation of Fuji Ortho for the direct bonding of orthodontic (metal) brackets with System 1+ (Ormco Corp.) as a control. Three failures of Fuji Ortho occurred from a sample of 60 (5%), with five failures of the composite resin from a sample of 60 (8.3%). No statistical significance was seen between these results. Fuji Ortho is a satisfactory adhesive for the direct bonding of orthodontic brackets where there are no occlusal interferences.

  20. CONDITIONAL FACTORIZATION BASED ON LATTICE THEORY FOR -INTEGERS

    Institute of Scientific and Technical Information of China (English)

    Zheng Yonghui; Zhu Yuefei

    2008-01-01

    In this paper, the integer N = pkq is called a -integer, if p and q are odd primes with almost the same size and k is a positive integer. Such integers were previously proposed for various cryptographic applications. The conditional factorization based on lattice theory for n-bit -integers is considered, and there is an algorithm in time polynomial in n to factor these integers if the least significant |(2k-1)n/(3k-1)(k-1)| bits of p are given.

  1. Finite Element Analysis on Rear Mounting Bracket of Hybrid Engine%混联式发动机后悬置支架有限元分析

    Institute of Scientific and Technical Information of China (English)

    刘善锷; 陈诗库; 张彦斌; 刘汨

    2015-01-01

    The engine rear mounting bracket is an important bearing member of powertrain,its strength must meet all requirements of all extreme conditions. The authors model and simulate the engine rear suspension bracket with the finite element analysis by use of Solidworks and Simulation softwares, as well as optimize the bracket structure. The results show that the optimize support can effectively reduce the stress of the key position,improve the safety performance of the engine mounting system.%发动机后悬置支架是动力总成的重要承载部件,其强度必须满足各种极限工况要求。本文利用Solidworks软件对发动机后悬置支架进行建模,利用Simulation软件进行有限元分析与结构优化。结果表明,优化后的支架有效地降低了关键部位的应力,提高了发动机悬置系统的安全性能。

  2. Identification of stiffness variations in supporting substances of a human canine tooth with a bracket-beam-piezoelectric sensor and its electromechanical impedance

    Directory of Open Access Journals (Sweden)

    Hector A. Tinoco

    2017-06-01

    Full Text Available In this paper, an experimental method is described to identify the stiffness variations produced by drillings done in different supporting substances of a human canine tooth. To measure the supporting substances parameters through of a canine, a sensor-actuator system was developed. The sensor-actuator device was composed of a stainless steel bracket bonded to a steel wire attached to two piezoelectric transducers, with a concentrated mass attached to the end of the wire. To excite the device, high frequency voltage (between 5 and 10 KHz was applied through the piezo-transducers, which affects the tooth by means of the vibration of the wire. High frequency mechanical vibrations allowed the appraisal of the mechanical response from the supporting substances. Mechanical responses associated with the stiffness of the support were quantified with the electrical impedance of the piezo-transducers. The device was coupled to the crown of a canine tooth simulating a condition of fixing as in the bone, the tooth was fastened by the root portion inside the supporting substance. Four supporting substances were characterized for the tests. After establishing base values of the stiffness of each supporting substance, the stiffness variations were assessed in two stages (two drillings; these were made perpendicularly to the longitudinal axis of the tooth, Results show that it is possible to assess stiffness variations with the proposed methodology as well as to quantify the stiffness differences, by means of variation indexes.

  3. Assessment of the hardness of different orthodontic wires and brackets produced by metal injection molding and conventional methods

    Directory of Open Access Journals (Sweden)

    Shiva Alavi

    2017-01-01

    Conclusion: MIM orthodontic brackets exhibited hardness values much lower than those of SS orthodontic archwires and were more compatible with NiTi and beta-titanium archwires. A wide range of microhardness values has been reported for conventional orthodontic brackets and it should be considered that the manufacturing method might be only one of the factors affecting the mechanical properties of orthodontic brackets including hardness.

  4. Corrosion Sensor Development for Condition-Based Maintenance of Aircraft

    Directory of Open Access Journals (Sweden)

    Gino Rinaldi

    2012-01-01

    Full Text Available Aircraft routinely operate in atmospheric environments that, over time, will impact their structural integrity. Material protection and selection schemes notwithstanding, recurrent exposure to chlorides, pollution, temperature gradients, and moisture provide the necessary electrochemical conditions for the development and profusion of corrosion in aircraft structures. For aircraft operators, this becomes an important safety matter as corrosion found in a given aircraft must be assumed to be present in all of that type of aircraft. This safety protocol and its associated unscheduled maintenance requirement drive up the operational costs of the fleet and limit the availability of the aircraft. Hence, there is an opportunity at present for developing novel sensing technologies and schemes to aid in shifting time-based maintenance schedules towards condition-based maintenance procedures. In this work, part of the ongoing development of a multiparameter integrated corrosion sensor is presented. It consists of carbon nanotube/polyaniline polymer sensors and commercial-off-the-shelf sensors. It is being developed primarily for monitoring environmental and material factors for the purpose of providing a means to more accurately assess the structural integrity of aerospace aluminium alloys through fusion of multiparameter sensor data. Preliminary experimental test results are presented for chloride ion concentration, hydrogen gas evolution, humidity variations, and material degradation.

  5. Bridge condition assessment based on long-term strain monitoring

    Science.gov (United States)

    Sun, LiMin; Sun, Shouwang

    2011-04-01

    In consideration of the important role that bridges play as transportation infrastructures, their safety, durability and serviceability have always been deeply concerned. Structural Health Monitoring Systems (SHMS) have been installed to many long-span bridges to provide bridge engineers with the information needed in making rational decisions for maintenance. However, SHMS also confronted bridge engineers with the challenge of efficient use of monitoring data. Thus, methodologies which are robust to random disturbance and sensitive to damage become a subject on which many researches in structural condition assessment concentrate. In this study, an innovative probabilistic approach for condition assessment of bridge structures was proposed on the basis of long-term strain monitoring on steel girder of a cable-stayed bridge. First, the methodology of damage detection in the vicinity of monitoring point using strain-based indices was investigated. Then, the composition of strain response of bridge under operational loads was analyzed. Thirdly, the influence of temperature and wind on strains was eliminated and thus strain fluctuation under vehicle loads is obtained. Finally, damage evolution assessment was carried out based on the statistical characteristics of rain-flow cycles derived from the strain fluctuation under vehicle loads. The research conducted indicates that the methodology proposed is qualified for structural condition assessment so far as the following respects are concerned: (a) capability of revealing structural deterioration; (b) immunity to the influence of environmental variation; (c) adaptability to the random characteristic exhibited by long-term monitoring data. Further examination of the applicability of the proposed methodology in aging bridge may provide a more convincing validation.

  6. Optimization of conditions for gene delivery system based on PEI

    Directory of Open Access Journals (Sweden)

    Roya Cheraghi

    2017-01-01

    Full Text Available Objective(s: PEI based nanoparticle (NP due to dual capabilities of proton sponge and DNA binding is known as powerful tool for nucleic acid delivery to cells. However, serious cytotoxicity and complicated conditions, which govern NPs properties and its interactions with cells practically, hindered achievement to high transfection efficiency. Here, we have tried to optimize the properties of PEI/ firefly luciferase plasmid complexes and cellular condition to improve transfection efficiency. Materials and Methods: For this purpose, firefly luciferase, as a robust gene reporter, was complexed with PEI to prepare NPs with different size and charge. The physicochemical properties of nanoparticles were evaluated using agarose gel retardation and dynamic light scattering.  MCF7 and BT474 cells at different confluency were also transfected with prepared nanoparticles at various concentrations for short and long times. Results: The branched PEI can instantaneously bind to DNA and form cationic NPs. The results demonstrated the production of nanoparticles with size about 100-500 nm dependent on N/P ratio. Moreover, increase of nanoparticles concentration on the cell surface drastically improved the transfection rate, so at a concentration of 30 ng/ìl, the highest transfection efficiency was achieved. On the other side, at confluency between 40-60%, the maximum efficiency was obtained. The result demonstrated that N/P ratio of 12 could establish an optimized ratio between transfection efficiency and cytotoxicity of PEI/plasmid nanoparticles. The increase of NPs N/P ratio led to significant cytotoxicity. Conclusion: Obtained results verified the optimum conditions for PEI based gene delivery in different cell lines.

  7. Adhesion strength of brackets repeated bonding in the same surface of enamel and reconditioned with different techniques

    OpenAIRE

    Luque Luque, Hugo Javier; Pérez Vargas, Luis Fernando; Dpto. Académico Estomatología Biosocial. Facultad Odontología. UNMSM. Lima, Perú.; Carhuamaca León, Gregorio Javier; Coronado Tamaríz, Marco Antonio

    2014-01-01

    Las fallas de adhesión y el reposicionamiento de brackets acontecen muy a menudo durante el tratamiento ortodóntico. Ante esta situación, el clínico puede optar por volver a adherir el mismo bracket del paciente o adherir uno nuevo. El estudio tuvo como objetivo determinar la variación de la fuerza de adhesión in vitro de brackets reacondicionados con las técnicas de flameado, microarenado y de brackets nuevos. 60 premolares sanas extraídos por indicación ortodóntica fueron agrupados aleatori...

  8. Evaluation of shear bond strength of metallic and ceramic brackets bonded to enamel prepared with self-etching primer.

    Science.gov (United States)

    Uysal, Tancan; Ustdal, Ayca; Kurt, Gokmen

    2010-04-01

    The aim of this in vitro study was to evaluate the shear bond strength (SBS) of different metallic and ceramic bracket bonding combinations using self-etching primers (SEPs). Eighty freshly extracted human premolar teeth were randomly divided into four equal groups for bonding with ceramic or metallic brackets as follows: group 1, metallic brackets bonded with conventional acid etching; group 2, metallic brackets bonded with Transbond Plus Self-Etching primer (TPSEP); group 3, ceramic brackets bonded as per group 1; group 4, ceramic brackets bonded as per group 2. The SBS of these brackets was measured and recorded in megapascals (MPa). The adhesive remnant index (ARI) scores were determined after bracket failure. Data were analyzed with the analysis of variance, Tukey, and chi-square tests. The bond strength of group 3 (mean: 36.7 +/- 11.8 MPa) was significantly higher than group 4 (mean: 26.6 +/- 8.9 MPa; P 0.05). Compared with conventional acid etching, SEPs significantly decreased the SBS of ceramic orthodontic brackets.

  9. Shear bond strength of ceramic and metallic orthodontic brackets bonded with self-etching primer and conventional bonding adhesives

    Science.gov (United States)

    Arash, Valiollah; Naghipour, Fatemeh; Ravadgar, Mehdi; Karkhah, Ahmad; Barati, Mohammad Saleh

    2017-01-01

    Introduction Adult patients typically require high-quality orthodontic treatment for ceramic brackets, but some clinicians remain concerned about the bond strength of these brackets. Therefore, the aim of this study was to determine the shear bond strength and de-bonding characteristics of metallic and ceramic brackets bonded with two types of bonding agents. Methods In an experimental study done in 2013 in Babol, Iran, 120 extracted human maxillary premolar teeth were randomly divided into four groups as follows: HM group: metallic bracket/conventional bonding agent; SM group: metallic bracket/Transbond self-etching primer; HC group: ceramic bracket/conventional bonding agent; SC group: ceramic bracket/Transbond self-etching primer. Twenty-four hours after thermocycling (1000 cycle, 5 °C–55 °C), the shear bond strength values were measured. The amount of resin remaining on the tooth surface (adhesive remnant index: ARI) was determined under a stereomicroscope. Enamel detachment index was evaluated under a scanning electron microscope. To perform statistical analysis, ANOVA, Kruskal–Wallis, and Tukey post-hoc tests were applied. The level of significance was set at p ceramic brackets. In addition, self-etching primer was able to produce fewer bonds compared with the conventional technique. Many samples showed the bracket-adhesive interface failure or failure inside the adhesive. PMID:28243410

  10. conditions

    Directory of Open Access Journals (Sweden)

    M. Venkatesulu

    1996-01-01

    Full Text Available Solutions of initial value problems associated with a pair of ordinary differential systems (L1,L2 defined on two adjacent intervals I1 and I2 and satisfying certain interface-spatial conditions at the common end (interface point are studied.

  11. Interactive edgewise mechanisms: form and function comparison with conventional edgewise brackets.

    Science.gov (United States)

    Voudouris, J C

    1997-02-01

    As the frequency of use of the interactive twin (I-twin) edgewise mechanisms and techniques become increasingly prevalent, it is important to consider how they compare with conventional twin (c-twin) edgewise bracket systems. Optimum intrabracket and interbracket forces in I-twins balance with capillary blood pressures. An unbiased, experimental in vitro, scanning electromicroscopy and in vivo clinical investigation of 83 patients was conducted to compare the frictional resistance of three different I-twin bracket systems, type A (Sigma, American Orthodontics), type B (Interactwin, Ormco Corp.), and type C (Damon, A-company) with three c-twins counterparts respectively types D, E, and F. The three interactive twin brackets were each self-seating by an integrated arm component and made significant incremental improvements to the conventional twins in three different ways. First, the I-twin types reduced frictional resistance by using arm engagement with a lower coefficient of friction and a reduced seating force against the arch wire. The reduced seating force friction produced initially small interbracket arch wire deflections for biocompatible tooth movement and, combined with a wide twin bracket, produced accurate rotation corrections. Reduced friction within the I-twin bracket consequently permitted the effective use of light forces for flowing biomechanics that maximized anchorage. In evaluating friction, two distinctly different interaction forces acting to seat the arch wire were also identified. Type A demonstrated active interaction with round arch wires that resulted in a low functional seating force responsible for early and complete tooth control in comparison to the high seating force of c-twins. Types B and C both showed passive interaction with seating force friction approximately equal to zero that required large rectangular dimension arch wires for full bracket expression. Second, a significant reduction in the time taken to change arch wires was

  12. The Optimization Design of Door Connecting Rod Bracket Structure of Civil Aircraft%民用飞机舱门连杆支架优化研究

    Institute of Scientific and Technical Information of China (English)

    袁修起

    2014-01-01

    The cabin latch mechanism of civil aircraft is to prevent the door accidentally open parts. When a jam occurs forced operation, it will produce a greater internal force. The equipment door latch mechanism is all stem shape and load is small except the connecting rod bracket. Connecting rod bracket structure is complex and load is bigger. Based on analyzingresistance load ,using the finite element analysis software HyperMesh and Opti-Struct , three kinds of structure forms of connecting rod bracket are simulated. With comparison and analysis, connecting rod bracket structure satisfied equipment doors functional requirements and prototype test purpose, which provides reference for the follow-up of the real product design.%民用飞机舱门闩机构是防止舱门意外开启的机构部件。当机构发生卡阻且强制操作时,将产生较大的内力。在设备舱门闩机构中除连杆支架外都是杆形件且载荷较小,连杆支架结构形式复杂且载荷较大。在分析机构卡阻载荷的基础上使用有限元分析软件HyperMesh和Opti-Struct对三种结构形式的连杆支架进行了数值模拟。通过对比分析,得到了满足样机设备舱门功能要求和试验目的的连杆支架形式,为后续真实产品的设计提供参考。

  13. Comparison of friction force between corroded and noncorroded titanium nitride plating of metal brackets.

    Science.gov (United States)

    Kao, Chia-Tze; Guo, Jia-Uei; Huang, Tsui-Hsien

    2011-05-01

    Titanium nitride (TiN) plating is a method to prevent metal corrosion and can increase the surface smoothness. The purpose of this study was to evaluate the friction forces between the orthodontic bracket, with or without TiN plating, and stainless steel wire after it was corroded in fluoride-containing solution. In total, 540 metal brackets were divided into a control group and a TiN-coated experimental group. The electrochemical corrosion was performed in artificial saliva with 1.23% acidulated phosphate fluoride (APF) as the electrolytes. Static and kinetic friction were measured by an EZ-test machine (Shimadazu, Tokyo, Japan) with a crosshead speed of 10 mm per minute over a 5-mm stretch of stainless steel archwire. The data were analyzed by using unpaired t test and analysis of variance (ANOVA). Both the control and TiN-coated groups' corrosion potential was higher with 1.23% APF solution than with artificial solution (P TiN-coated brackets groups showed a statistically significant difference (P TiN-coated brackets showed a statistical difference (P TiN-coated metal brackets, with corrosion or without corrosion, cannot reduce the frictional force. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  14. The effect of enamel bleaching on the shear bond strengths of metal and ceramic brackets.

    Science.gov (United States)

    Oztaş, E; Bağdelen, G; Kiliçoğlu, H; Ulukapi, H; Aydin, I

    2012-04-01

    The aim of this study was to evaluate the effects of bleaching and delayed bonding on the shear bond strengths of metal and ceramic brackets bonded with light and chemically cure composite resin to human enamel. One hundred and twenty extracted human premolar teeth were randomly divided into three groups of 40 each. The first two groups were bleached with 20 per cent carbamide peroxide (CP) at-home bleaching agent. No bleaching procedures were applied to the third group and served as control. The first two and control groups were divided into equal subgroups according to different adhesive-bracket combinations. Specimens in group 1 (n = 40) were bonded 24 hours after bleaching process was completed while the specimens in group 2 (n = 40) were bonded 14 days after. The specimens in all groups were debonded with a Universal testing machine while the modified adhesive remnant index was used to evaluate fracture properties. No statistically significant differences were found between the shear bond strengths of metal and ceramic brackets bonded to bleached enamel after 24 hours, 14 days, and unbleached enamel with light or chemical cure adhesives (P > 0.05). The mode of failure was mostly at the bracket/adhesive interface and cohesive failures within the resin were also observed. Our findings indicated that at-home bleaching agents that contain 20 per cent CP did not significantly affect the shear bond strength of metal and ceramic orthodontic brackets to enamel when bonding is performed 24 hours or 14 days after bleaching.

  15. Efficacy of quercetin flavonoid in recovering the postbleaching bond strength of orthodontic brackets: A preliminary study

    Science.gov (United States)

    Shamsedin, Mana; Arash, Valiollah; Jahromi, Masoud Babaei; Moghadamnia, Ali Akbar; Kamel, Manouchehr Rahmati; Ezoji, Fariba; bijani, Ali; Kavoli, Samira; Ghasemi, Tania; Ramezani, Gholamhossein

    2017-01-01

    Objectives: To evaluate comparatively the effect of quercetin on postbleaching shear bond strength (SBS) and adhesive remnant index (ARI). Materials and Methods: Intact maxillary premolars were divided randomly into 12 groups of 10 each: (1) bonding the bracket immediately after bleaching, (2) bonding 1 week after bleaching, (3–8) application of three experimental concentrations of quercetin (0.1%, 0.5%, and 1%) at two time durations (5 and 10 min), (9–10) application of the solvent of quercetin at two time periods (5 and 10 min), (11) application of 10% sodium ascorbate for 10 min, and (12) bonding the brackets on nonbleached teeth. Bleaching was performed using 15% carbamide peroxide gel for 5 days (6 h daily). After incubation and thermocycling, the SBS of brackets was measured. The ARI too was recorded at ×20. The data were analyzed statistically (α =0.05). Results: Bleaching reduced the SBS below 10 Megapascal (MPa) level (P 0.01). All eight postbleaching treatments had rather similar efficacies (P = 0.1396). The concentration of quercetin (beta = 0.259, P = 0.042) but not its duration (beta = 0.213, P = 0.093) significantly improved its efficacy. Conclusion: Bleaching can weaken the bond strength of orthodontic brackets below acceptable levels. The application of quercetin or Vitamin C or delaying the bracket bonding improved the postbleaching SBS. PMID:28197398

  16. Evaluation of Antibacterial Effects of Silver-Coated Stainless Steel Orthodontic Brackets

    Directory of Open Access Journals (Sweden)

    Valiollah Arash

    2016-08-01

    Full Text Available Objectives: White spots and enamel demineralization around orthodontic brackets are among the most important complications resulting from orthodontic treatments. Since the antibacterial properties of metals and metallic particles have been well documented, the aim of this study was to assess the antibacterial effect of stainless steel orthodontic brackets coated with silver (Ag particles.Materials and Methods: In this study, 40 standard metal brackets were divided into two groups of 20 cases and 20 controls. The brackets in the case group were coated with Ag particles using an electroplating method. Atomic force microscopy (AFM and scanning electron microscopy (SEM were used to assess the adequacy of the coating process. In addition, antibacterial tests, i.e., disk diffusion and direct contact tests were performed at three, six, 24and 48 hours, and 15 and 30 days using a Streptococcus mutans strain. The results were analyzed using Student’s t-test and repeated measures ANOVA.Conclusions: Brackets coated with Ag, via an electroplating method, exhibited antibacterial properties when placed in direct contact with Streptococcus mutans. This antibacterial effect persisted for 30 days after contact with the bacteria.

  17. Orthodontic Metallic Lingual Brackets: The Dark Side of the Moon of Bond Failures?

    Directory of Open Access Journals (Sweden)

    Maria Francesca Sfondrini

    2017-07-01

    Full Text Available Lingual orthodontics, among both young and adult patients, increased in popularity during last years. The purposes of the present investigation were to evaluate the shear bond strength (SBS values and Adhesive Remnant Index (ARI scores of different lingual brackets compared with a vestibular control bracket. One hundred bovine teeth were extracted and embedded in resin blocks. Four different lingual brackets (Idea, Leone; STB, Ormco; TTR, RMO; 2D, Forestadent and a vestibular control bracket (Victory, 3M were bonded to the bovine enamel surfaces and subsequently shear tested to failure utilizing a Universal Testing Machine. SBS values were measured. A microscopic evaluation was performed to obtain ARI scores. Statistical analysis was performed at a statistically significant level of p < 0.05 to determine significant differences in SBS values and ARI Scores. No statistically significant variations in SBS were reported among the different groups. Conversely, significant differences were shown in ARI scores among the various groups. Clinical relevance of the present study is that orthodontists can expect similar resistance to debonding forces from lingual appliances as with vestibular brackets.

  18. In vitro analysis of shear bond strength and adhesive remnant index of different metal brackets

    Directory of Open Access Journals (Sweden)

    Fernanda de Souza Henkin

    Full Text Available ABSTRACT Introduction: There is a great variety of orthodontic brackets in the Brazilian market, and constantly evaluating them is critical for professionals to know their properties, so as to be able to choose which product best suits their clinical practice. Objectives: To evaluate the bond strength and the adhesive remnant index (ARI of different brands of metal brackets. Material and Methods: A total of 105 bovine incisors were used, and brackets of different brands were bonded to teeth. Seven different bracket brands were tested (MorelliTM, American OrthodonticsTM, TP OrthodonticsTM, Abzil-3MTM, OrthometricTM, TecnidentTM and UNIDENTM. Twenty-four hours after bonding, shear bond strength test was performed; and after debonding, the ARI was determined by using an optical microscope at a 10-fold increase. Results: Mean shear bond strength values ranged from 3.845 ± 3.997 (MorelliTM to 9.871 ± 5.106 MPa (TecnidentTM. The majority of the ARI index scores was 0 and 1. Conclusion: Among the evaluated brackets, the one with the lowest mean shear bond strength values was MorelliTM. General evaluation of groups indicated that a greater number of bond failure occurred at the enamel/adhesive interface.

  19. In vitro analysis of shear bond strength and adhesive remnant index of different metal brackets

    Science.gov (United States)

    Henkin, Fernanda de Souza; de Macêdo, Érika de Oliveira Dias; Santos, Karoline da Silva; Schwarzbach, Marília; Samuel, Susana Maria Werner; Mundstock, Karina Santos

    2016-01-01

    ABSTRACT Introduction: There is a great variety of orthodontic brackets in the Brazilian market, and constantly evaluating them is critical for professionals to know their properties, so as to be able to choose which product best suits their clinical practice. Objectives: To evaluate the bond strength and the adhesive remnant index (ARI) of different brands of metal brackets. Material and Methods: A total of 105 bovine incisors were used, and brackets of different brands were bonded to teeth. Seven different bracket brands were tested (MorelliTM, American OrthodonticsTM, TP OrthodonticsTM, Abzil-3MTM, OrthometricTM, TecnidentTM and UNIDENTM). Twenty-four hours after bonding, shear bond strength test was performed; and after debonding, the ARI was determined by using an optical microscope at a 10-fold increase. Results: Mean shear bond strength values ranged from 3.845 ± 3.997 (MorelliTM) to 9.871 ± 5.106 MPa (TecnidentTM). The majority of the ARI index scores was 0 and 1. Conclusion: Among the evaluated brackets, the one with the lowest mean shear bond strength values was MorelliTM. General evaluation of groups indicated that a greater number of bond failure occurred at the enamel/adhesive interface. PMID:28125142

  20. Shear bond strength of metallic and ceramic brackets using color change adhesives

    Directory of Open Access Journals (Sweden)

    Aisha de Souza Gomes Stumpf

    2013-04-01

    Full Text Available OBJECTIVE: To determine the shear bond strength of orthodontic brackets using color change adhesives that are supposed to aid in removing excess of bonding material and compare them to a traditional adhesive. METHODS: Ninety metallic and ninety ceramic brackets were bonded to bovine incisors using two color change adhesives and a regular one. A tensile stress was applied by a universal testing machine. The teeth were observed in a microscope after debonding in order to determine the Adhesive Remnant Index (ARI. RESULTS: The statistical analysis (ANOVA, Tukey, and Kruskall-Wallis tests demonstrated that the mean bond strength presented no difference when metallic and ceramic brackets were compared but the bond resistance values were significantly different for the three adhesives used. The most common ARI outcome was the entire adhesive remaining on the enamel. CONCLUSIONS: The bond strength was similar for metallic and ceramic brackets when the same adhesive system was used. ARI scores demonstrated that bonding with these adhesives is safe even when ceramic brackets were used. On the other hand, bond strength was too low for orthodontic purposes when Ortho Lite Cure was used.

  1. Pulpal Thermal Changes following Er-YAG Laser Debonding of Ceramic Brackets

    Directory of Open Access Journals (Sweden)

    Didem Nalbantgil

    2014-01-01

    Full Text Available Lasers are effective in debonding ceramic brackets. Unfortunately, while reducing the adhesive bond strength, lasers are also reported to increase pulpal temperature. The aim of this study was to evaluate the shear bond strengths and temperature increase levels after debonding ceramic brackets using an Er-YAG laser with or without water-cooling. Sixty polycrystalline upper premolar ceramic brackets were placed on the labial surface of sixty human premolar teeth which were randomly divided into three groups of twenty. A laser pulse at 5 W for 9 seconds was delivered to each bracket in both study groups either with water-cooling (water group or without water-cooling (waterless group using an Er-YAG laser. Debonding was performed 45 seconds after laser exposure and shear bond strengths were measured. Data comparison revealed a statistically significant difference between the groups. Mean temperature increases of 2.41°C and 4.59°C were recorded for the water and waterless laser groups, respectively. The shear bond strength value for the control group was 22.76 MPa and 10.46 and 6.36 MPa for the water and waterless laser groups, respectively. The application of Er-YAG laser with water-cooling was an efficient and safe method of debonding ceramic brackets.

  2. Influence of lingual bracket position on microbial and periodontal parameters in vivo

    Directory of Open Access Journals (Sweden)

    Maria Francesca Sfondrini

    2012-06-01

    Full Text Available OBJECTIVE: Lingual orthodontics is becoming more popular in dental practice. The purpose of the present investigation was to compare plaque formation on teeth bonded with the same bracket onto buccal or lingual surface, with non-bonded control teeth, via an in vivo growth experiment over a 30-day period. MATERIAL AND METHODS: A randomized controlled trial with split-mouth design was set up enrolling 20 dental students. Within each subject sites with buccal and lingual brackets and control sites were followed. Clinical periodontal parameters (periodontal pocket depth: PPD; bleeding on probing: BOP were recorded at baseline and on days 1, 7 and 30. Microbiological samples were taken from the brackets and the teeth on days 1, 7 and 30 to detect colony-forming units (CFU. Total CFU, streptococci CFU and anaerobe CFU were measured. RESULTS: No significant differences (P>0.05 were found between buccal and lingual brackets in terms of clinical periodontal parameters and microbiological values. Conclusion: Bracket position does not have significant impact on bacterial load and on periodontal parameters.

  3. Bearing Fault Classification Based on Conditional Random Field

    Directory of Open Access Journals (Sweden)

    Guofeng Wang

    2013-01-01

    Full Text Available Condition monitoring of rolling element bearing is paramount for predicting the lifetime and performing effective maintenance of the mechanical equipment. To overcome the drawbacks of the hidden Markov model (HMM and improve the diagnosis accuracy, conditional random field (CRF model based classifier is proposed. In this model, the feature vectors sequences and the fault categories are linked by an undirected graphical model in which their relationship is represented by a global conditional probability distribution. In comparison with the HMM, the main advantage of the CRF model is that it can depict the temporal dynamic information between the observation sequences and state sequences without assuming the independence of the input feature vectors. Therefore, the interrelationship between the adjacent observation vectors can also be depicted and integrated into the model, which makes the classifier more robust and accurate than the HMM. To evaluate the effectiveness of the proposed method, four kinds of bearing vibration signals which correspond to normal, inner race pit, outer race pit and roller pit respectively are collected from the test rig. And the CRF and HMM models are built respectively to perform fault classification by taking the sub band energy features of wavelet packet decomposition (WPD as the observation sequences. Moreover, K-fold cross validation method is adopted to improve the evaluation accuracy of the classifier. The analysis and comparison under different fold times show that the accuracy rate of classification using the CRF model is higher than the HMM. This method brings some new lights on the accurate classification of the bearing faults.

  4. Comparison of Galvanic Currents Generated Between Different Combinations of Orthodontic Brackets and Archwires Using Potentiostat: An In Vitro Study.

    Science.gov (United States)

    Nayak, Rabindra S; Shafiuddin, Bareera; Pasha, Azam; Vinay, K; Narayan, Anjali; Shetty, Smitha V

    2015-07-01

    Technological advances in wire selection and bracket design have led to improved treatment efficiency and allowed longer time intervals between appliance adjustments. The wires remain in the mouth for a longer duration and are subjected to electrochemical reactions, mechanical forces of mastication and generalized wear. These cause different types of corrosion. This study was done to compare the galvanic currents generated between different combinations of brackets and archwires commonly used in orthodontic practices. The materials used for the study included different commercially available orthodontic archwires and brackets. The galvanic current generated by individual materials and different combinations of these materials was tested and compared. The orthodontic archwires used were 0.019″ × 0.025″ heat-activated nickel-titanium (3M Unitek), 0.019″ × 0.025″ beta-titanium (3M Unitek) and 0.019″ × 0.025″ stainless steel (3M Unitek). The orthodontic brackets used were 0.022″ MBT laser-cut (Victory Series, 3M Unitek) and metal-injection molded (Leone Company) maxillary central incisor brackets respectively. The ligature wire used for ligation was 0.009″ stainless steel ligature (HP Company). The galvanic current for individual archwires, brackets, and the different bracket-archwire-ligature combinations was measured by using a Potentiostat machine. The data were generated using the Linear Sweep Voltammetry and OriginPro 8.5 Graphing and Data Analysis Softwares. The study was conducted in two phases. Phase I comprised of five groups for open circuit potential (OCP) and galvanic current (I), whereas Phase II comprised of six groups for galvanic current alone. Mean, standard deviation and range were computed for the OCP and galvanic current (I) values obtained. Results were subjected to statistical analysis through ANOVA. In Phase I, higher mean OCP was recorded in stainless steel archwire, followed by beta-titanium archwire, heat-activated nickel

  5. Methods for removal of resin remaining after debonding of orthodontic brackets: A literature review

    Directory of Open Access Journals (Sweden)

    Mateus Rodrigues Tonetto

    2014-01-01

    Full Text Available The removal of resin debris and/or resin cement from the enamel surface without causing iatrogenic is the main objective when removing the orthodontic brackets. Some factors such as the time required for removal, damage to the tooth structure, are essential factors for the clinician at the time of removal. Various techniques are used for the removal of orthodontic brackets after the treatment; it is known that the use of clinical procedures such as the use of diamond burs and some pliers removers can damage the structure of the enamel, often depending on the bond strength that should be taken into consideration at the time of removal. This literature review aims to gather the most relevant studies that can clarify the clinical technique, which may be more suitable for removal of the brackets.

  6. Patch-based iterative conditional geostatistical simulation using graph cuts

    Science.gov (United States)

    Li, Xue; Mariethoz, Gregoire; Lu, DeTang; Linde, Niklas

    2016-08-01

    Training image-based geostatistical methods are increasingly popular in groundwater hydrology even if existing algorithms present limitations that often make real-world applications difficult. These limitations include a computational cost that can be prohibitive for high-resolution 3-D applications, the presence of visual artifacts in the model realizations, and a low variability between model realizations due to the limited pool of patterns available in a finite-size training image. In this paper, we address these issues by proposing an iterative patch-based algorithm which adapts a graph cuts methodology that is widely used in computer graphics. Our adapted graph cuts method optimally cuts patches of pixel values borrowed from the training image and assembles them successively, each time accounting for the information of previously stitched patches. The initial simulation result might display artifacts, which are identified as regions of high cost. These artifacts are reduced by iteratively placing new patches in high-cost regions. In contrast to most patch-based algorithms, the proposed scheme can also efficiently address point conditioning. An advantage of the method is that the cut process results in the creation of new patterns that are not present in the training image, thereby increasing pattern variability. To quantify this effect, a new measure of variability is developed, the merging index, quantifies the pattern variability in the realizations with respect to the training image. A series of sensitivity analyses demonstrates the stability of the proposed graph cuts approach, which produces satisfying simulations for a wide range of parameters values. Applications to 2-D and 3-D cases are compared to state-of-the-art multiple-point methods. The results show that the proposed approach obtains significant speedups and increases variability between realizations. Connectivity functions applied to 2-D models transport simulations in 3-D models are used to

  7. The noncommutative Poisson bracket and the deformation of the family algebras

    Science.gov (United States)

    Wei, Zhaoting

    2015-07-01

    The family algebras are introduced by Kirillov in 2000. In this paper, we study the noncommutative Poisson bracket P on the classical family algebra 𝒞τ(𝔤). We show that P controls the first-order 1-parameter formal deformation from 𝒞τ(𝔤) to 𝒬τ(𝔤) where the latter is the quantum family algebra. Moreover, we will prove that the noncommutative Poisson bracket is in fact a Hochschild 2-coboundary, and therefore, the deformation is infinitesimally trivial. In the last part of this paper, we discuss the relation between Mackey's analogue and the quantization problem of the family algebras.

  8. Qualitative Research of AZ31 Magnesium Alloy Aircraft Brackets Produced by a New Forging Method

    Directory of Open Access Journals (Sweden)

    Dziubińska A.

    2016-06-01

    Full Text Available The paper reports a selection of numerical and experimental results of a new closed-die forging method for producing AZ31 magnesium alloy aircraft brackets with one rib. The numerical modelling of the new forming process was performed by the finite element method.The distributions of stresses, strains, temperature and forces were examined. The numerical results confirmed that the forgings produced by the new forming method are correct. For this reason, the new forming process was verified experimentally. The experimental results showed good agreement with the numerical results. The produced forgings of AZ31 magnesium alloy aircraft brackets with one rib were then subjected to qualitative tests.

  9. Oral bacterial adhesion forces to biomaterial surfaces constituting the bracket-adhesive-enamel junction in orthodontic treatment

    NARCIS (Netherlands)

    Mei, Li; Busscher, Henk J; van der Mei, Henny C; Chen, Yangxi; de Vries, Joop; Ren, Yijin

    2009-01-01

    Bacterial adhesion to biomaterial surfaces constituting the bracket-adhesive-enamel junction represents a growing problem in orthodontics, because bacteria can adversely affect treatment by causing demineralization of the enamel surface around the brackets. It is important to know the forces with wh

  10. Oral bacterial adhesion forces to biomaterial surfaces constituting the bracket-adhesive-enamel junction in orthodontic treatment

    NARCIS (Netherlands)

    Mei, Li; Busscher, Henk J; van der Mei, Henny C; Chen, Yangxi; de Vries, Joop; Ren, Yijin

    Bacterial adhesion to biomaterial surfaces constituting the bracket-adhesive-enamel junction represents a growing problem in orthodontics, because bacteria can adversely affect treatment by causing demineralization of the enamel surface around the brackets. It is important to know the forces with

  11. The discoloring effects of food on the color stability of esthetic brackets - an in-vitro study

    NARCIS (Netherlands)

    Wriedt, Susanne; Schepke, Ulf; Wehrbein, Heiner

    2007-01-01

    Aim: The purpose of this study was to investigate the discoloring effect of certain foods on the color stability of esthetic brackets made of different materials. Material and Methods: Ten specimens of six different tooth-colored brackets were immersed for 10 days at 37 degrees C in various solution

  12. Does It Help to Use Mathematically Superfluous Brackets When Teaching the Rules for the Order of Operations?

    Science.gov (United States)

    Gunnarsson, Robert; Sönnerhed, Wang Wei; Hernell, Bernt

    2016-01-01

    The hypothesis that mathematically superfluous brackets can be useful when teaching the rules for the order of operations is challenged. The idea of the hypothesis is that with brackets it is possible to emphasize the order priority of one operation over another. An experiment was conducted where expressions with mixed operations were studied,…

  13. Effect of clearfil protect bond and transbond plus self-etch primer on shear bond strength of orthodontic brackets

    Directory of Open Access Journals (Sweden)

    S Hamid Raji

    2011-01-01

    Conclusion: The shear bond strength of clearfil protect bond and transbond plus self-etch primer was enough for bonding the orthodontic brackets. The mode of failure of bonded brackets with these two self-etch primers is safe for enamel.

  14. Bio-inspired computational techniques based on advanced condition monitoring

    Institute of Scientific and Technical Information of China (English)

    Su Liangcheng; He Shan; Li Xiaoli; Li Xinglin

    2011-01-01

    The application of bio-inspired computational techniques to the field of condition monitoring is addressed.First, the bio-inspired computational techniques are briefly addressed; the advantages and disadvantages of these computational methods are made clear. Then, the roles of condition monitoring in the predictive maintenance and failures prediction and the development trends of condition monitoring are discussed. Finally, a case study on the condition monitoring of grinding machine is described, which shows the application of bio-inspired computational technique to a practical condition monitoring system.

  15. Tropospheric Delay Analysis Based on Some Chinese Cities' Meteorologic Conditions

    Science.gov (United States)

    Liu, Q.; Chen, X. H.; Sun, J. Z.; Han, B. B.; Zhang, Q.

    2014-03-01

    With the increase of the users' precision in satellite orientation and navigation, the influence of the tropospheric delay has become increasingly vital, which needs to be corrected. The paper contrastively analyzes some main mapping functions' models of the tropospheric delay theory. It discusses the distributions of the hydrostatic/wet mapping functions of Niell Mapping Function (NMF), Vienna Mapping Function 1 (VMF1), and Global Mapping Function (GMF). And it analyzes tropospheric delay based on the meteorologic conditions in some Chinese cities. It could be concluded from the results that the hydrostatic VMF1 and GMF are in yearly periodic cosine distributions and approximately identical, whereas the hydrostatic NMF is roughly larger than the formers. The wet VMF1, which is influenced greatly by the atmosphere, displays close to cosine functions. Besides, VMF1 and GMF roughly display minimum in summer and maximum in winter, respectively. While the elevation angle is 10 degrees, the Slant Propagation Delays (SPDs) of the chosen stations are all in yearly periodic cosine distributions, and they decrease with the increase of the latitude. The SPD reaches maximum in summer and minimum in winter, and the difference is about 2 m.

  16. Assessment of Structural Damage Condition Based on Fuzzy Pattern Recognition

    Institute of Scientific and Technical Information of China (English)

    WU Zi-yan; ZHANG Yu

    2008-01-01

    This paper presents a new method of damage condition assessment that allows accommodating other types of uncertainties due to ambiguity, vagueness, and fuzziness that are statistically non-describable. In this method, healthy observations are used to construct a fuzzy set representing sound performance characteristics. Additionally, the bounds on the similarities among the structural damage states are prescribed by using the state similarity matrix. Thus, an optimal group fuzzy sets representing damage states such as little, moderate, and severe damage can be inferred as an inverse problem from healthy observations only. The optimal group of damage fuzzy sets is used to classify a set of observations at any unknown state of damage using the principles of fuzzy pattern recognition based on an approximate principle. This method can be embedded into the system of Structural Health Monitoring (SHM) to give advice about structural maintenance and life prediction. Finally, a case study, which comes from Reference [9] for damage pattern recognition is presented and discussed. The compared result illustrates our method is more effective and general, so it is very practical in engineering.

  17. Network Based Real Time Condition Monitoring of Rotating Machinery

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    This paper presents the development of a network based real time condition monitoring system of rotating machinery. The system is built up in a double net structure consisting of local net (including client and server) and intranet. The client serves as a field data collector and processor that samples the vibration signals and process parameters of a machine monitored in the net and processes the sampled data. The data collected by the client are transmitted to the server that processes the data further and provides the results of the diagnosis of each machine to any distant terminals through intranet or internet. Such a structure of the monitoring system is advantageous in safety, reliability and reasonably shares the existing net resources. In order to ensure real time transmission of the data, two procedures of data transmission, virtual channel and data pool, are developed and applied in the monitoring system. The experimental results show that the monitoring system works well and is suitable to monitor a large group of rotating machines.

  18. Designing a future Conditions Database based on LHC experience

    CERN Document Server

    Barberis, D; Gallas, E J; Govi, G; Miotto, G Lehman; Pfeiffer, A

    2015-01-01

    Starting from the experience collected by the ATLAS and CMS experiments in handling condition data during the first LHC run, we present a proposal for a new generation of condition databases, which could be implemented by 2020. We will present the identified relevant data flows for condition data and underline the common use cases that lead to a joint effort for the development of a new system.Condition data is needed in any scientific experiment. It includes any ancillary data associated with primary data taking such as detector configuration, state or calibration or the environment in which the detector is operating. Condition data typically reside outside the primary data store for various reasons (size, complexity or availability) and are best accessed at the point of processing or analysis (including for Monte Carlo simulations). The ability of any experiment to produce correct and timely results depends on the complete and efficient availability of needed conditions for each stage of data handling. Ther...

  19. Condition Based Monitoring of Gas Turbine Combustion Components

    Energy Technology Data Exchange (ETDEWEB)

    Ulerich, Nancy; Kidane, Getnet; Spiegelberg, Christine; Tevs, Nikolai

    2012-09-30

    The objective of this program is to develop sensors that allow condition based monitoring of critical combustion parts of gas turbines. Siemens teamed with innovative, small companies that were developing sensor concepts that could monitor wearing and cracking of hot turbine parts. A magnetic crack monitoring sensor concept developed by JENTEK Sensors, Inc. was evaluated in laboratory tests. Designs for engine application were evaluated. The inability to develop a robust lead wire to transmit the signal long distances resulted in a discontinuation of this concept. An optical wear sensor concept proposed by K Sciences GP, LLC was tested in proof-of concept testing. The sensor concept depended, however, on optical fiber tips wearing with the loaded part. The fiber tip wear resulted in too much optical input variability; the sensor could not provide adequate stability for measurement. Siemens developed an alternative optical wear sensor approach that used a commercial PHILTEC, Inc. optical gap sensor with an optical spacer to remove fibers from the wearing surface. The gap sensor measured the length of the wearing spacer to follow loaded part wear. This optical wear sensor was developed to a Technology Readiness Level (TRL) of 5. It was validated in lab tests and installed on a floating transition seal in an F-Class gas turbine. Laboratory tests indicate that the concept can measure wear on loaded parts at temperatures up to 800{degrees}C with uncertainty of < 0.3 mm. Testing in an F-Class engine installation showed that the optical spacer wore with the wearing part. The electro-optics box located outside the engine enclosure survived the engine enclosure environment. The fiber optic cable and the optical spacer, however, both degraded after about 100 operating hours, impacting the signal analysis.

  20. Conditional Quantile Processes based on Series or Many Regressors

    CERN Document Server

    Belloni, Alexandre; Fernandez-Val, Ivan

    2011-01-01

    Quantile regression (QR) is a principal regression method for analyzing the impact of covariates on outcomes. The impact is described by the conditional quantile function and its functionals. In this paper we develop the nonparametric QR series framework, covering many regressors as a special case, for performing inference on the entire conditional quantile function and its linear functionals. In this framework, we approximate the entire conditional quantile function by a linear combination of series terms with quantile-specific coefficients and estimate the function-valued coefficients from the data. We develop large sample theory for the empirical QR coefficient process, namely we obtain uniform strong approximations to the empirical QR coefficient process by conditionally pivotal and Gaussian processes, as well as by gradient and weighted bootstrap processes. We apply these results to obtain estimation and inference methods for linear functionals of the conditional quantile function, such as the conditiona...

  1. Dirichlet-Neumann bracketing for boundary-value problems on graphs

    Directory of Open Access Journals (Sweden)

    Sonja Currie

    2005-08-01

    Full Text Available We consider the spectral structure of second order boundary-value problems on graphs. A variational formulation for boundary-value problems on graphs is given. As a consequence we can formulate an analogue of Dirichlet-Neumann bracketing for boundary-value problems on graphs. This in turn gives rise to eigenvalue and eigenfunction asymptotic approximations.

  2. A Mathematica program for the calculation of five-body Moshinsky brackets

    Science.gov (United States)

    Xiao, Shuyuan; Mu, Xueli; Liu, Tingting; Chen, Hong

    2016-06-01

    Five-body Moshinsky brackets that relate harmonic oscillator wavefunctions in two different sets of Jacobi coordinates make it straightforward to calculate some matrix elements in the variational calculations of five-body systems. The analytical expression of these transformation coefficients and the computer code written in the Mathematica language are presented here for accurate calculations.

  3. Evaluation of shear bond strength of orthodontic brackets bonded on the tooth surface after internal bleaching

    Directory of Open Access Journals (Sweden)

    Nadia de Souza FERREIRA

    Full Text Available Introduction: There is great demand for esthetic treatment by patients who have discolored teeth, because currently aesthetic standards have become stricter and many patients have tooth bleaching procedures performed before or during orthodontic treatment. Objective: To evaluate the bonding of orthodontic brackets to human molars after internal tooth bleaching. Material and method: Forty molars were divided into four groups according to the bleaching agent used: PS sodium perborate + water; PC carbamide peroxide; PC + PS carbamide peroxide + sodium perborate; Cont water (control group. Bleaching agents placed inside the pulp chambers were replaced every 7 days for 2 weeks, and the brackets were bonded 30 days after the end of bleaching. The shear strength test was performed in a universal testing machine (Emic. Result: ANOVA with a significance level of 5% (p > 0.05, showed no statistically significant difference between groups (p = 0.1214. Conclusion: It was concluded that the different bleaching agents studied did not interfere with the bond strength of brackets to enamel and bonding the brackets 30 days after internal bleaching is a safe procedure.

  4. Effect of Enamel Preparation and Light Curing Methods on Microleakage under Orthodontic Brackets

    Directory of Open Access Journals (Sweden)

    Hamidreza Pakshir

    2015-11-01

    Full Text Available Objectives: This study aimed to compare the microleakage beneath metallic brackets following two different methods of enamel preparation and light curing.Materials and Methods: A total of 120 bovine deciduous lower incisors were randomly divided into four groups of 30 teeth. The preparations were as follows: Group I: Acid etching + Transbond XT primer + direct illumination, group II: acid etching + Transbond XT primer + transillumination, group III: Transbond XT self-etching primer + direct illumination and Group IV: Transbond XT self-etching primer + transillumination. Dye penetration was used as the method of microleakage evaluation. Sections made at the enamel-adhesive and adhesive-bracket interfaces were evaluated under a stereomicroscope. The Kruskal-Wallis and Mann-Whitney U tests were used for statistical analysis. The level of significance was set at P<0.05.Results: All groups showed greater microleakage at the gingival in comparison to the incisal margin and the differences were significant among groups with transillumination (P<0.001. No significant differences were observed in the microleakage scores at the gingival and incisal margins in any of the interfaces (P>0.05. Mesiodistal margins of the self-etching group with direct illumination showed significantly lower scores in comparison with acid etched group (P<0.05.Conclusion: Use of self-etching primers for bonding of orthodontic brackets yields acceptable results if all bracket margins are cured directly.

  5. Effects of different chlorhexidine pretreatments on adhesion of metal brackets in vitro

    Directory of Open Access Journals (Sweden)

    Frey Corinne

    2012-12-01

    Full Text Available Abstract Objective To investigate the effect of chlorhexidine applications in various forms and concentrations on adhesion and failure modes of metal brackets in vitro. Material and methods Ninety bovine enamel specimens were allocated to six groups (n=15. Metal brackets were bonded on all specimens after chlorhexidine pre-treatments forming the following groups: (1 untreated specimens (control; (2 40% varnish (EC40, Biodent BV, Netherlands, remnants removed with brushing mimicking patient cleaning; (3 40% varnish (EC40, remnants removed with brushing mimicking professional cleaning; (4 1% varnish (Cervitec Plus, Ivoclar vivadent, Schaan, Liechtenstein, remnants not removed; (5 brushed with% 1 gel (Corsodyl, GlaxoSmithKline, Münchenbuchsee, Germany, remnants not removed; (6 immersed in 0.07% mouthrinse (Corsodyl, GlaxoSmithKline, Münchenbuchsee, Germany, remnant not rinsed. Debonding of brackets was performed using a universal testing machine. Data were analysed using one-way ANOVA and post-hoc Scheffé test. Results Group 4 performed significantly inferior than all the other groups and the control. Group 4 presented the highest number of adhesive failures at the enamel-resin interface whereas in other groups no failures at adhesive-resin interface was observed. Conclusion Presence of chlorhexidine varnish prior to bracket bonding adversely affects adhesion. Concentration of chlorhexidine pre-treatment has no influence on shear bond strength.

  6. Effect of toothbrushing with different manual toothbrushes on the shear bond strength of orthodontic brackets

    Directory of Open Access Journals (Sweden)

    Guilherme José Pimentel Lopes de Oliveira

    2010-09-01

    Full Text Available The aim of this study was to evaluate the effect of brushing with a Colgate 360º or Oral B Indicator 35 toothbrush on the shear bond strength of orthodontic brackets bonded to extracted human teeth. The bristle wear and bristle tip morphology were also examined after simulated tooth-brushing. Orthodontic brackets (Roth-P/1st and 2nd premolar S/D- Slot 0.18" were bonded (Transbond XT® to the smoothest surface of each of 45 extracted human molar and premolar teeth. Test specimens were randomly divided into three groups: Group 1, control group with no brushing; Group 2, brushing with the Oral B Indicator 35; Group 3, brushing with the Colgate 360º. Samples were adapted to a machine that simulated tooth-brushing. The bond strength of each bracket to each tooth was assessed with a mechanical testing machine. The bristle wear and bristle tip morphology indices were also assessed. Statistically significant differences were defined for p < 0.05. The average bond strengths (range: 90.18-90.89 kgf/cm² did not differ among the three groups. The Colgate 360º showed less bristle wear and a better bristle tip morphology than the Oral B Indicator 35 toothbrush. However, use of either toothbrush did not decrease the bond strength of the orthodontic brackets. Therefore, patients undergoing orthodontic therapy can safely use either toothbrush.

  7. Analysis on the precision of the dimensions of self-ligating brackets.

    Science.gov (United States)

    Erduran, Rackel Hatice Milhomens Gualberto; Maeda, Fernando Akio; Ortiz, Sandra Regina Mota; Triviño, Tarcila; Fuziy, Acácio; Carvalho, Paulo Eduardo Guedes

    2016-12-01

    The present study aimed to evaluate the precision of the torque applied by 0.022" self-ligating brackets of different brands, the precision of parallelism between the inner walls of their slots, and precision of their slot height. Eighty brackets for upper central incisors of eight trademarked models were selected: Abzil, GAC, American Orthodontics, Morelli, Orthometric, Ormco, Forestadent, and Ortho Organizers. Images of the brackets were obtained using a scanning electron microscope (SEM) and these were measured using the AutoCAD 2011 software. The tolerance parameters stated in the ISO 27020 standard were used as references. The results showed that only the Orthometric, Morelli, and Ormco groups showed results inconsistent with the ISO standard. Regarding the parallelism of the internal walls of the slots, most of the models studied had results in line with the ISO prescription, except the Morelli group. In assessing bracket slot height, only the Forestadent, GAC, American Orthodontics, and Ormco groups presented results in accordance with the ISO standard. The GAC, Forestadent, and American Orthodontics groups did not differ in relation to the three factors of the ISO 27020 standard. Great variability of results is observed in relation to all the variables. © 2016 Wiley Periodicals, Inc.

  8. Are self-ligating brackets related to less formation of Streptococcus mutans colonies? A systematic review.

    Science.gov (United States)

    do Nascimento, Leonard Euler Andrade Gomes; de Souza, Margareth Maria Gomes; Azevedo, Angela Rita Pontes; Maia, Lucianne Cople

    2014-01-01

    To verify, by means of a systematic review, whether the design of brackets (conventional or self-ligating) influences adhesion and formation of Streptococcus mutans colonies. four databases (Cochrane Central Register of Controlled Trials, Ovid ALL EMB Reviews, PubMed and BIREME) were selected to search for relevant articles covering the period from January 1965 to December 2012. in first consensus by reading the title and abstract. The full text was obtained from publications that met the inclusion criteria. Two reviewers independently extracted data using the following keywords: conventional, self-ligating, biofilm, Streptococcus mutans, and systematic review; and independently evaluated the quality of the studies. In case of divergence, the technique of consensus was adopted. The search strategy resulted in 1,401 articles. The classification of scientific relevance revealed the high quality of the 6 eligible articles of which outcomes were not unanimous in reporting not only the influence of the design of the brackets (conventional or self-ligating) over adhesion and formation of colonies of Streptococcus mutans, but also that other factors such as the quality of the bracket type, the level of individual oral hygiene, bonding and age may have greater influence. Statistical analysis was not feasible because of the heterogeneous methodological design. Within the limitations of this study, it was concluded that there is no evidence for a possible influence of the design of the brackets (conventional or self-ligating) over colony formation and adhesion of Streptococcus mutans.

  9. Quantification of white spot lesions around orthodontic brackets with image analysis.

    NARCIS (Netherlands)

    Livas, C.; Kuijpers-Jagtman, A.M.; Bronkhorst, E.; Derks, A.; Katsaros, C.

    2008-01-01

    OBJECTIVE: To investigate the use of image analysis for diagnosis and quantification of artificial white spot lesions on digital photographs before and after removal of orthodontic brackets. MATERIALS AND METHODS: Enamel demineralization was artificially induced on the labial surface of 20 teeth

  10. Shear bond strength of brackets rebonded with a fluoride-releasing and -recharging adhesive system.

    Science.gov (United States)

    Endo, Toshiya; Ozoe, Rieko; Shinkai, Koichi; Aoyagi, Makiko; Kurokawa, Hiroomi; Katoh, Yoshiroh; Shimooka, Shohachi

    2009-05-01

    To ascertain the effects of repeated bonding on the shear bond strength of orthodontic brackets bonded with a fluoride-releasing and -recharging adhesive system with a self-etching primer in comparison with two other types of adhesive system. A total of 48 premolars were collected and divided equally into three groups of 16. Each group was assigned one of three adhesive systems: Transbond XT, Transbond Plus, or a fluoride-releasing and -recharging adhesive system, Beauty Ortho Bond. Shear bond strength was measured 24 hours after bracket bonding, with the bonding/debonding procedures repeated twice after the first debonding. A universal testing machine was used to determine shear bond strengths, and bracket/adhesive failure modes were evaluated with the adhesive remnant index after each debonding. At every debonding sequence, all of these three adhesive systems had a shear bond strength of 6 MPa, which is a minimum requirement for clinical use. Transbond XT and Transbond Plus had significantly higher mean shear bond strengths than did Beauty Ortho Bond at each debonding. No significant differences in mean bond strength were observed between the three debondings in each adhesive system. Bond failure at the enamel/adhesive interface occurred more frequently in Beauty Ortho Bond than in Transbond XT or Transbond Plus. The fluoride-releasing and -recharging adhesive system with the self-etching primer (Beauty Ortho Bond) had clinically sufficient shear bond strength in repeated bracket bonding; this finding can help orthodontists to decrease the risk of damage to enamel at debonding.

  11. Difference equations and cluster algebras I: Poisson bracket for integrable difference equations

    CERN Document Server

    Inoue, Rei

    2010-01-01

    We introduce the cluster algebraic formulation of the integrable difference equations, the discrete Lotka-Volterra equation and the discrete Liouville equation, from the view point of the general T-system and Y-system. We also study the Poisson structure for the cluster algebra, and give the associated Poisson bracket for the two difference equations.

  12. Quantification of white spot lesions around orthodontic brackets with image analysis.

    NARCIS (Netherlands)

    Livas, C.; Kuijpers-Jagtman, A.M.; Bronkhorst, E.; Derks, A.; Katsaros, C.

    2008-01-01

    OBJECTIVE: To investigate the use of image analysis for diagnosis and quantification of artificial white spot lesions on digital photographs before and after removal of orthodontic brackets. MATERIALS AND METHODS: Enamel demineralization was artificially induced on the labial surface of 20 teeth bon

  13. Manufacturing and assembly of IWS support rib and lower bracket for ITER vacuum vessel

    Science.gov (United States)

    Laad, R.; Sarvaiya, Y.; Pathak, H. A.; Raval, J. R.; Choi, C. H.

    2017-04-01

    ITER Vacuum Vessel (VV) is made of double walls connected by ribs structure and flexible housings. Space between these walls is filled up with In Wall Shielding (IWS) blocks to (1) shield neutrons streaming out of plasma and (2) reduce toroidal magnetic field ripple. These blocks will be connected to the VV through a supporting structure of Support Rib (SR) and Lower Bracket (LB) assembly. SR and LB are two independent components manufactured from SS 316L(N)-IG, Total 1584 support ribs and 3168 lower bracket of different sizes and shapes will be manufactured for the IWS. Two lower brackets will be welded with one support rib to make an assembly. The welding between SR and LB is a full penetration welding. Total 1584 assemblies of different sizes and shapes will be manufactured. Sufficient experience gained from manufacturing and testing of mock ups, final manufacturing of IWS support rib and lower bracket has been started at the site of IWS manufacturer M/s. Avasarala Technologies Limited (ATL). This paper will describe, optimization of water jet cutting speed on IWS material, selection criteria for K type weld joint, unique features of fixture of assembly, manufacturing of Mock ups, and welding processes with NDTs.

  14. Actual versus theoretical torsional play in conventional and self-ligating bracket systems

    DEFF Research Database (Denmark)

    Dalstra, Michel; Eriksen, Henrik; Bergamini, Chiara;

    2015-01-01

    Abstract Objective: The aim of this study was to assess the amount of torsional play in 32 commercially available self-ligating and conventional 0·018-inch and 0·022-inch bracket systems in relation to 0·017×0·022-inch and 0·019×0·025-inch stainless steel wires, respectively, and compare the resu...

  15. Effect of tooth displacement and vibration on frictional force and stick-slip phenomenon in conventional brackets: a preliminary in vitro mechanical analysis.

    Science.gov (United States)

    Seo, Yu-Jin; Lim, Bum-Soon; Park, Young Guk; Yang, Il-Hyung; Ahn, Seok-Joon; Kim, Tae-Woo; Baek, Seung-Hak

    2015-04-01

    To evaluate the effects of tooth displacement and vibration on frictional force and stick-slip phenomenon (SSP) when conventional brackets were used with a levelling/alignment wire. The samples consisted of six groups (n = 10 per group) with combinations of tooth displacement (2mm lingual displacement [LD], 2mm gingival displacement [GD], and no displacement [control]) and vibration conditions (absence and presence at 30 Hz and 0.25 N). A stereolithographically made typodont system was used with conventional brackets and elastomeric ligatures. After application of artificial saliva, static/kinetic frictional forces (SFF/KFF) and frequency/amplitude of SSP were measured while drawing a 0.018-inch copper nickel-titanium (Cu-NiTi) archwire at a speed of 0.5mm/min for 5 minutes at 36.5 degree celsius. Two-way analysis of variance and independent t-test were performed. Tooth displacement increased SFF and KFF (control [LD, GD], P < 0.01). Vibration reduced SFF, KFF, and SSP amplitude in the control group (P < 0.05, P < 0.05, and P < 0.001, respectively), but not in the LD and GD groups. SSP frequency was increased by vibration in the control, LD, and GD groups (all P < 0.001), and it was lower in the LD and GD groups than in the control group (P < 0.01). When conventional brackets and a 0.018-inch Cu-NiTi archwire were used in the tooth displacement conditions (LD and GD), vibration did not significantly reduce SFF, KFF, or SSP amplitude. © The Author 2014. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  16. Designing a future Conditions Database based on LHC experience

    CERN Document Server

    Formica, Andrea; The ATLAS collaboration; Gallas, Elizabeth; Govi, Giacomo; Lehmann Miotto, Giovanna; Pfeiffer, Andreas

    2015-01-01

    The ATLAS and CMS Conditions Database infrastructures have served each of the respective experiments well through LHC Run 1, providing efficient access to a wide variety of conditions information needed in online data taking and offline processing and analysis. During the long shutdown between Run 1 and Run 2, we have taken various measures to improve our systems for Run 2. In some cases, a drastic change was not possible because of the relatively short time scale to prepare for Run 2. In this process, and in the process of comparing to the systems used by other experiments, we realized that for Run 3, we should consider more fundamental changes and possibilities. We seek changes which would streamline conditions data management, improve monitoring tools, better integrate the use of metadata, incorporate analytics to better understand conditions usage, as well as investigate fundamental changes in the storage technology, which might be more efficient while minimizing maintenance of the data as well as simplif...

  17. Evaluation of enamel damages following orthodontic bracket debonding in fluorosed teeth bonded with adhesion promoter.

    Science.gov (United States)

    Baherimoghadam, Tahreh; Akbarian, Sahar; Rasouli, Reza; Naseri, Navid

    2016-01-01

    To evaluate shear bond strength (SBS) of the orthodontic brackets bonded to fluorosed and nonfluorosed teeth using Light Bond with and without adhesion promoters and compare their enamel damages following debonding. In this study, 30 fluorosed (Thylstrup and Fejerskov Index = 4-5) and 30 nonfluorosed teeth were randomly distributed between two subgroups according to the bonding materials: Group 1, fluorosed teeth bonded with Light Bond; Group 2, fluorosed teeth bonded with adhesion promoters and Light Bond; Group 3, nonfluorosed teeth bonded with Light Bond; Group 4, nonfluorosed bonded with adhesion promoters and Light Bond. After bonding, the SBS of the brackets was tested with a universal testing machine. Stereomicroscopic evaluation was performed by unbiased stereology in all teeth to determine the amount of adhesive remnants and the number and length of enamel cracks before bonding and after debonding. The data were analyzed using two-way analysis of variance, Kruskal-Wallis, Wilcoxon Signed Rank, and Mann-Whitney test. While fluorosis reduced the SBS of orthodontic bracket (P = 0.017), Enhance Locus Ceruleus LC significantly increased the SBS of the orthodontic bracket in fluorosed and nonfluorosed teeth (P = 0.039). Significant increasing in the number and length of enamel crack after debonding was found in all four groups. There were no significant differences in the length of enamel crack increased after debonding among four groups (P = 0.768) while increasing in the number of enamel cracks after debonding was significantly different among the four groups (P = 0.023). Teeth in Group 2 showed the highest enamel damages among four groups following debonding. Adhesion promoters could improve the bond strength of orthodontic brackets, but conservative debonding methods for decreasing enamel damages would be necessary.

  18. Evaluation of enamel damages following orthodontic bracket debonding in fluorosed teeth bonded with adhesion promoter

    Science.gov (United States)

    Baherimoghadam, Tahreh; Akbarian, Sahar; Rasouli, Reza; Naseri, Navid

    2016-01-01

    Objective: To evaluate shear bond strength (SBS) of the orthodontic brackets bonded to fluorosed and nonfluorosed teeth using Light Bond with and without adhesion promoters and compare their enamel damages following debonding. Materials and Methods: In this study, 30 fluorosed (Thylstrup and Fejerskov Index = 4–5) and 30 nonfluorosed teeth were randomly distributed between two subgroups according to the bonding materials: Group 1, fluorosed teeth bonded with Light Bond; Group 2, fluorosed teeth bonded with adhesion promoters and Light Bond; Group 3, nonfluorosed teeth bonded with Light Bond; Group 4, nonfluorosed bonded with adhesion promoters and Light Bond. After bonding, the SBS of the brackets was tested with a universal testing machine. Stereomicroscopic evaluation was performed by unbiased stereology in all teeth to determine the amount of adhesive remnants and the number and length of enamel cracks before bonding and after debonding. The data were analyzed using two-way analysis of variance, Kruskal–Wallis, Wilcoxon Signed Rank, and Mann–Whitney test. Results: While fluorosis reduced the SBS of orthodontic bracket (P = 0.017), Enhance Locus Ceruleus LC significantly increased the SBS of the orthodontic bracket in fluorosed and nonfluorosed teeth (P = 0.039). Significant increasing in the number and length of enamel crack after debonding was found in all four groups. There were no significant differences in the length of enamel crack increased after debonding among four groups (P = 0.768) while increasing in the number of enamel cracks after debonding was significantly different among the four groups (P = 0.023). Teeth in Group 2 showed the highest enamel damages among four groups following debonding. Conclusion: Adhesion promoters could improve the bond strength of orthodontic brackets, but conservative debonding methods for decreasing enamel damages would be necessary. PMID:27095895

  19. Evaluation of enamel micro-cracks characteristics after removal of metal brackets in adult patients.

    Science.gov (United States)

    Dumbryte, Irma; Linkeviciene, Laura; Malinauskas, Mangirdas; Linkevicius, Tomas; Peciuliene, Vytaute; Tikuisis, Kristupas

    2013-06-01

    The purpose of this study was to evaluate and compare enamel micro-crack characteristics of adult patients before and after removal of metal brackets. After the examination with scanning electron microscopy (SEM), 45 extracted human teeth were divided into three groups of equal size: group 1, the teeth having enamel micro-cracks, group 2, the teeth without initial enamel micro-cracks, and group 3, control group to study the effect of dehydration on existing micro-cracks or formation of new ones. For all the teeth in groups 1 and 2, the same bonding and debonding procedures of metal brackets were conducted. The length and width of the longest enamel micro-crack were measured for all the teeth before and after removal of metal brackets. The changes in the location of the micro-cracks were also evaluated. In group 3, teeth were subjected to the same analysis but not bonded. The mean overall width of micro-cracks after removal of metal brackets was 3.82 μm greater than before bonding procedure (P micro-cracks in first zone (cervical third) and third zone (occlusal third) after debonding procedure (P micro-cracks were found in 6 of 15 (40 per cent) examined teeth. Greatest changes in the width of enamel micro-cracks after debonding procedure appear in the cervical third of the tooth. On the basis of this result, the dentist must pay extra care and attention to this specific area of enamel during removal of metal brackets in adult patients.

  20. PERBANDINGAN TEKNIS DAN EKONOMIS ANTARA PENGGANTIAN BANTALAN POROS PROPELLER DIBANDINGKAN DENGAN PENGGESERAN POSISI V-BRACKET PADA KMP. KUMALA

    Directory of Open Access Journals (Sweden)

    Untung Budiarto

    2012-02-01

    Full Text Available In the propulsion systems there are three preference components main engine, propeller shaft, and propeller.KMP. Kumala is one for all passengers ship the owner PT. Darma Lautan Utama, there are it’s to experienceproblems to the systems propulsion to happen missalignment between construction v-bracket with sterntube,there are v-bracket to function become to hold up propeller shaft in the inside to find shaft bearing. Effect themissalignment, shaft can’t to turn, so need the realized preparing with the change to shaft bearing shapeexentric and to scrape position v-bracket the position again. In this finish task purporting to know the valuefrom side technics and economics between to realized the change shaft bearing shape exentric with to scrapeposition v-bracket to position again with account time to docking next time. From the result analyse to find thatto change the shaft bearing shape exentric to need faster time, material cost is more expensive, labour cost ischeaper, construction to v-bracket isn’t normaly, than to scrape position v-bracket to need the time is long time,material cost is cheaper, job cost is more expensive, construction v-bracket back to normal the position again,until to moment realization docking next time to need faster time, material cost and job cost is cheaper from tochange the shaft bearing shape exentric.

  1. Evaluation of the force generated by gradual deflection of orthodontic wires in conventional metallic, esthetic, and self-ligating brackets

    Directory of Open Access Journals (Sweden)

    Manoela Fávaro Francisconi

    Full Text Available ABSTRACT Objective: The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires placed in different types of brackets: metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating, by assessing strength values variation according to gradual increase in wire diameter and deflection and comparing different combinations in the different deflections. Material and Methods: Specimens were set in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342, using the ISO 15841 protocol. Data were subjected to One-way ANOVA, followed by Tukey tests (p<0.05. Results: Self-ligating brackets presented the most similar behavior to each other. For conventional brackets there was no consistent behavior for any of the deflections studied. Conclusions: Self-ligating brackets presented the most consistent and predictable results while conventional brackets, as esthetic brackets, showed very different patterns of forces. Self-ligating brackets showed higher strength in all deflections when compared with the others, in 0.020-inch wires.

  2. Evaluation of the influence of porcelain conditioning techniques in orthodontic brackets bonding

    OpenAIRE

    Camila Belo Falcão; Adriano Marques Brito; Fernando Jorge Mendes Ahid

    2009-01-01

    OBJETIVO: o objetivo deste trabalho foi avaliar a influência do tipo de tratamento superficial da porcelana na resistência adesiva da colagem de braquetes ortodônticos e o modo de fratura após a descolagem. METODOLOGIA:foram confeccionados 80 corpos-de-prova de porcelana, divididos em quatro grupos (n = 18) de acordo com os diferentes tratamentos de superfície: (G1) ponta diamantada; (G2) ponta diamantada e silano; (G3) ácido hidrofluorídrico e (G4) ácido hidrofluorídrico e silano. Após o pre...

  3. Estimating Outdoor Illumination Conditions Based on Detection of Dynamic Shadows

    DEFF Research Database (Denmark)

    Madsen, Claus B.; Lal, Brajesh Behari

    2013-01-01

    The paper proposes a technique for estimation outdoor illumination conditions in terms of sun and sky radiances directly from pixel values of dynamic shadows detected in video sequences produved by a commercial stereo camera. The technique is applied to the rendering of virtual object into the im......The paper proposes a technique for estimation outdoor illumination conditions in terms of sun and sky radiances directly from pixel values of dynamic shadows detected in video sequences produved by a commercial stereo camera. The technique is applied to the rendering of virtual object...

  4. Clustering condition-based maintenance for a multi-unit system with aperiodic inspections

    NARCIS (Netherlands)

    Olde Keizer, Minou C.A.; Teunter, Ruud H.; Podofillini, Luca; Sudret, Bruno; Stojadinović, Božidar; Zio, Enrico; Kröger, Wolfgang

    2015-01-01

    Condition-Based Maintenance (CBM) is a predictive maintenance strategy, which bases the maintenance scheduling on condition measurements of the components. In this paper, we continue work on the CBM optimization approach proposed by Castanier, B., A. Grall & C. Bérenguer (2005). A condition-based

  5. Clustering condition-based maintenance for a multi-unit system with aperiodic inspections

    NARCIS (Netherlands)

    Olde Keizer, Minou C.A.; Teunter, Ruud H.; Podofillini, Luca; Sudret, Bruno; Stojadinović, Božidar; Zio, Enrico; Kröger, Wolfgang

    2015-01-01

    Condition-Based Maintenance (CBM) is a predictive maintenance strategy, which bases the maintenance scheduling on condition measurements of the components. In this paper, we continue work on the CBM optimization approach proposed by Castanier, B., A. Grall & C. Bérenguer (2005). A condition-based ma

  6. Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements

    Directory of Open Access Journals (Sweden)

    Grace Kelly Martins Carneiro

    2015-08-01

    Full Text Available OBJECTIVE: The aim of this study was to assess whether repetitive opening and closure of self-ligating bracket clips can cause plastic deformation of the clip.METHODS: Three types of active/interactive ceramic self-ligating brackets (n = 20 were tested: In-Ovation C, Quicklear and WOW. A standardized controlled device performed 500 cycles of opening and closure movements of the bracket clip with proper instruments and techniques adapted as recommended by the manufacturer of each bracket type. Two tensile tests, one before and one after the repetitive cycles, were performed to assess the stiffness of the clips. To this end, a custom-made stainless steel 0.40 x 0.40 mm wire was inserted into the bracket slot and adapted to the universal testing machine (EMIC DL2000, after which measurements were recorded. On the loading portion of the loading-unloading curve of clips, the slope fitted a first-degree equation curve to determine the stiffness/deflection rate of the clip.RESULTS: The results of plastic deformation showed no significant difference among bracket types before and after the 500 cycles of opening and closure (p = 0.811. There were significant differences on stiffness among the three types of brackets (p = 0.005. The WOW bracket had higher mean values, whereas Quicklear bracket had lower values, regardless of the opening/closure cycle.CONCLUSION: Repetitive controlled opening and closure movements of the clip did not alter stiffness or cause plastic deformation.

  7. Comparison of Antibacterial Effects of ZnO and CuO Nanoparticles Coated Brackets against Streptococcus Mutans

    Directory of Open Access Journals (Sweden)

    Baratali Ramazanzadeh

    2015-09-01

    Full Text Available Statement of the Problem: During the orthodontic treatment, microbial plaques may accumulate around the brackets and cause caries, especially in high-risk patients. Finding ways to eliminate this microbial plaque seems to be essential. Purpose: The aim of this study was to compare the antibacterial effects of nano copper oxide (CuO and nano zinc oxide (ZnO coated brackets against Streptococcus mutans (S.mutans in order to decrease the risk of caries around the orthodontic brackets during the treatment. Materials and Method: Sixty brackets were coated with nanoparticles of ZnO (n=20, CuO (n=20 and CuO-ZnO (n=20. Twelve uncoated brackets constituted the control group. The brackets were bonded to the crowns of extracted premolars, sterilized and prepared for antimicrobial tests (S.mutans ATCC35668. The samples taken after 0, 2, 4, 6 and 24 hours were cultured on agar plates. Colonies were counted 24 hours after incubation. One-way ANOVA and Tukey tests were used for statistical analysis. Results: In CuO and CuO-ZnO coated brackets, no colony growth was seen after two hours. Between 0-6 hours, the mean colony counts were not significantly different between the ZnO and the control group (p>0.05. During 6-24 hours, the growth of S.mutans was significantly reduced by ZnO nanoparticles in comparison with the control group (p< 0.001. However, these bacteria were not totally eliminated. Conclusion: CuO and ZnO-CuO nanoparticles coated brackets have better antimicrobial effect on S.mutans than ZnO coated brackets.

  8. A Comparison of the Shear Bond Strength of Orthodontic Brackets Bonded With Light-Emitting Diode and Halogen Light-Curing Units

    Directory of Open Access Journals (Sweden)

    SM. Abtahi

    2006-09-01

    Full Text Available Statement of the problem: Various methods such as light emitting diode (LED have been used to enhance the polymerization of resin-based orthodontic adhesives. There is a lack of information on the advantages and disadvantages of different light curing systems.Purpose: The aim of this study was to compare the effect of LED and halogen light curing systems on the shear bond strength of orthodontic brackets.Materials and Methods: Forty extracted human premolars were etched with 37% phosphoric acid and cleansed with water spray and air dried. The sealant was applied on the tooth surface and the brackets were bonded using Transbond adhesive (3M Unitek,Monrovia, Calif. Adhesives were cured for 40 and 20 seconds with halogen (Blue Light, APOZA, Taiwan and LED (Blue dent, Smart, Yugoslavia light-curing systems,respectively. Specimens were thermocycled 2500 times (from 5 to 55 °C and the shear bond strength of the adhesive system was evaluated with an Universal testing machine (Zwick GmbH, Ulm, Germany at a crosshead speed of 1 mm/min until the bracketswere detached from the tooth. Adhesive remnant index (ARI scores were determined after bracket failure. The data were submitted to statistical analysis, using Mann-Whitney analysis and t-test.Results: No significant difference was found in bond strength between the LED and halogen groups (P=0.12. A significant difference was not observed in the adhesive remnant index scores between the two groups (P=0.97.Conclusion: Within the limitations of this in vitro study, the shear bond strength of resin-based orthodontic adhesives cured with a LED was statistically equivalent to those cured with a conventional halogen-based unit. LED light-curing units can be suggested for the polymerization of orthodontic bonding adhesives.

  9. Evaluation of ionic degradation and slot corrosion of metallic brackets by the action of different dentifrices

    Directory of Open Access Journals (Sweden)

    Gustavo Antônio Martins Brandão

    2013-02-01

    Full Text Available OBJECTIVE: To evaluate the in vitro ionic degradation and slot base corrosion of metallic brackets subjected to brushing with dentifrices, through analysis of chemical composition by Energy Dispersive Spectroscopy (EDS and qualitative analysis by Scanning Electron Microscopy (SEM. METHODS: Thirty eight brackets were selected and randomly divided into four experimental groups (n = 7. Two groups (n = 5 worked as positive and negative controls. Simulated orthodontic braces were assembled using 0.019 x 0.025-in stainless steel wires and elastomeric rings. The groups were divided according to surface treatment: G1 (Máxima Proteção Anticáries®; G2 (Total 12®; G3 (Sensitive®; G4 (Branqueador®; Positive control (artificial saliva and Negative control (no treatment. Twenty eight brushing cycles were performed and evaluations were made before (T0 and after (T1 experiment. RESULTS: The Wilcoxon test showed no difference in ionic concentrations of titanium (Ti, chromium (Cr, iron (Fe and nickel (Ni between groups. G2 presented significant reduction (p OBJETIVO: avaliar in vitro a degradação iônica e corrosão do fundo do slot de braquetes metálicos submetidos à escovação com dentifrícios, realizando análises da composição química por Espectroscopia de Energia Dispersiva (EDS e qualitativa por Microscopia Eletrônica de Varredura (MEV. MÉTODOS: foram selecionados 38 braquetes divididos aleatoriamente em quatro grupos experimentais (n = 7. Dois grupos (n = 5 funcionaram como controles positivo e negativo. Aparelhos ortodônticos simulados foram confeccionados com fios de aço inoxidável 0,019" x 0,025" e anéis elastoméricos. Os grupos foram divididos de acordo com o tratamento de superfície: G1 (Máxima Proteção Anticáries®; G2 (Total 12®; G3 (Sensitive®; G4 (Branqueador®; Controle Positivo (saliva artificial e Controle Negativo (sem tratamento. Foram realizados 28 ciclos de escovação e avaliações antes (T0 e após (T1 o

  10. Reverse convex problems: an approach based on optimality conditions

    Directory of Open Access Journals (Sweden)

    Ider Tseveendorj

    2006-01-01

    Full Text Available We present some results concerning reverse convex problems. Global optimality conditions for the problems with a nonsmooth reverse convex constraint are established and convergence of an algorithm in the case of linear program with an additional quadratic reverse convex constraint is studied.

  11. Air Conditioning, Heating, and Refrigeration. Competency-Based Curriculum Manual.

    Science.gov (United States)

    Gourley, Frank A., Jr.

    This manual was developed to serve as an aid to administrators and instructors involved with postsecondary air conditioning, heating, and refrigeration programs. The first of six chapters contains general information on program implementation, the curriculum design, facilities and equipment requirements, and textbooks and references. Chapter 2…

  12. Predicting Siltation in Entrance Channel Based on Wind Conditions

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The siltation induced by wind waves in an entrance channel is one of the prime factors influencing the operation efficiency of a port. It is necessary to predict the siltation accurately for dredging and ship operation passing through the entrance of the port. However, it is difficult to apply the traditional method to predicting entrance siltation because of its complex computational procedure and lacking the data of ocean dynamic elements in the specified sea area. From the view of energy conservation, a direct relationship between wind conditions and sediment deposition can be founded. On the basis of the above methodology, an empirical formula expressed by wind conditions for forecasting the siltation in the entrance channel is set up. The wind conditions are easily obtained from the local meteorological stations or weather maps, so the formula established in this paper is more convenient and practical than the traditional method. A case study is provided, in which the emopirical formula is calibrated and verified utilizing the measured wind and siltation conditions in the entrance channel of the port. Comparisons between computed values and measured data show satisfactory agreement.

  13. Reverse convex problems: an approach based on optimality conditions

    OpenAIRE

    Ider Tseveendorj

    2006-01-01

    We present some results concerning reverse convex problems. Global optimality conditions for the problems with a nonsmooth reverse convex constraint are established and convergence of an algorithm in the case of linear program with an additional quadratic reverse convex constraint is studied.

  14. Anterior Sectional Twin Bracket Appliance - Innovative Use for Correction of Single Tooth Crossbite: A Case Report with Biomechanics.

    Science.gov (United States)

    Verma, Raj Kumar; Raghav, Pradeep; Reddy, Munish C; Kanwal, Ritika

    2015-01-01

    Anterior sectional twin bracket appliance (ASTBA) is a sectional mechanism that involves two brackets on upper central incisors. This appliance is previously been used for correction of rotated incisors and midline spacing. But, detail biomechanics for single tooth crossbite correction is not previously explained. Here, in this article, we are presenting a detailed biomechanics of ASTBA for anterior single tooth crossbite correction along with case report. How to cite this article: Verma RK, Raghav P, Reddy MC, Kanwal R. Anterior Sectional Twin Bracket Appliance- Innovative Use for Correction of Single Tooth Crossbite: A Case Report with Biomechanics. Int J Clin Pediatr Dent 2015;8(1): 66-69.

  15. Deproteinization of tooth enamel surfaces to prevent white spot lesions and bracket bond failure: A revolution in orthodontic bonding

    Directory of Open Access Journals (Sweden)

    Roberto Justus

    2016-01-01

    Full Text Available Orthodontic treatment success is jeopardized by the risk of development of white spot lesions (WSLs around orthodontic brackets. Unfortunately, the formation of WSLs still remains a common complication during treatment in patients with poor oral hygiene. Nearly 75% of orthodontic patients are reported to develop enamel decalcification because of prolonged plaque retention around brackets. It is the orthodontist′s responsibility to minimize the risk of patients having enamel decalcifications as a consequence of orthodontic treatment. This can be achieved by using hybrid, fluoride-releasing, glass ionomer cement to bond brackets, with deproteinization of the enamel surface before phosphoric acid etching.

  16. Conditional random field-based gesture recognition with depth information

    Science.gov (United States)

    Chung, Hyunsook; Yang, Hee-Deok

    2013-01-01

    Gesture recognition is useful for human-computer interaction. The difficulty of gesture recognition is that instances of gestures vary both in motion and shape in three-dimensional (3-D) space. We use depth information generated using Microsoft's Kinect in order to detect 3-D human body components and apply a threshold model with a conditional random field in order to recognize meaningful gestures using continuous motion information. Body gesture recognition is achieved through a framework consisting of two steps. First, a human subject is described by a set of features, encoding the angular relationship between body components in 3-D space. Second, a feature vector is recognized using a threshold model with a conditional random field. In order to show the performance of the proposed method, we use a public data set, the Microsoft Research Cambridge-12 Kinect gesture database. The experimental results demonstrate that the proposed method can efficiently and effectively recognize body gestures automatically.

  17. Condition monitoring of reciprocating seal based on FBG sensors

    Science.gov (United States)

    Zhao, Xiuxu; Zhang, Shuanshuan; Wen, Pengfei; Zhen, Wenhan; Ke, Wei

    2016-07-01

    The failure of hydraulic reciprocating seals will seriously affect the normal operation of hydraulic reciprocating machinery, so the potential fault condition monitoring of reciprocating seals is very important. However, it is extremely difficult because of the limitation of reciprocating motion and the structure constraints of seal groove. In this study, an approach using fiber Bragg grating (FBG) sensors is presented. Experimental results show that the contact strain changes of a reciprocating seal can be detected by FBG sensors in the operation process of the hydraulic cylinders. The failure condition of the reciprocating seal can be identified by wavelet packet energy entropy, and the center frequency of power spectrum analysis. It can provide an effective solution for the fault prevention and health management of reciprocating hydraulic rod seals.

  18. Moment Conditions Selection Based on Adaptive Penalized Empirical Likelihood

    Directory of Open Access Journals (Sweden)

    Yunquan Song

    2014-01-01

    Full Text Available Empirical likelihood is a very popular method and has been widely used in the fields of artificial intelligence (AI and data mining as tablets and mobile application and social media dominate the technology landscape. This paper proposes an empirical likelihood shrinkage method to efficiently estimate unknown parameters and select correct moment conditions simultaneously, when the model is defined by moment restrictions in which some are possibly misspecified. We show that our method enjoys oracle-like properties; that is, it consistently selects the correct moment conditions and at the same time its estimator is as efficient as the empirical likelihood estimator obtained by all correct moment conditions. Moreover, unlike the GMM, our proposed method allows us to carry out confidence regions for the parameters included in the model without estimating the covariances of the estimators. For empirical implementation, we provide some data-driven procedures for selecting the tuning parameter of the penalty function. The simulation results show that the method works remarkably well in terms of correct moment selection and the finite sample properties of the estimators. Also, a real-life example is carried out to illustrate the new methodology.

  19. Shear bond strength of recycled metal brackets%金属托槽重复利用的抗剪切强度

    Institute of Scientific and Technical Information of China (English)

    刘新强; 李正明; 马长柏; 张丁; 孙志辉

    2008-01-01

    BACKGROUND: Bracket dropping is often seen in clinic. Can these shed brackets be used again; what should be done to treat these brackets; is the bond strength of these recycled brackets different from those new ones, these questions are often concerned by orthodontists in their clinic and are the purpose of our study as well.OBJECTIVE: To evaluate the shear bond strength and compare two base-cure methods of recycled brackets. DESIGN: Grouping control study. SITTING: Department of Orthodontics, the Affiliated Hospital of Medical College, Qingdao University; Department of Materials, Dental School, Beijing University. MATERIALS: The teeth were collected from Oral Surgery, the Affiliated Hospital of Medical College, Qingdao University. The age was from 11 to 19 years. The gender was half male and half female. Intact enamel of the crown was required, but decayed, fracture, tetracycline pigmentation teeth or fluorosis teeth were excluded. Patients provided the confirmed consent for this experiment.METHODS: The experiment was carried out in Stomatology College of Peaking University in December 2005. Thirty ex vivo teeth were selected randomly from those prepared enamel surfaces, used as sample for rebounding. The edgewise brackets of swallow-tailed brackets were bonded on each tooth and rebonded after 24 hours. The teeth were cleaned and divided randomly into 3 groups. There were 10 teeth in each group. Group 1 was bonded with new brackets; group 2 with recycled brackets whose adhesive remnant were burned and got rid of; group 3 with recycled brackets whose adhesive remnant in the groove of the base were stored. Bracket was provided by Standard edgewise, Orsu Company, Hangzhou, China. After 24 hours, the shear bond strength was tested with material testing machine (Autogragh, Shimadzu, Japan). Adhesive remnant index (ARI) was added up. MAIN OUTCOME MEASURES: Shear strength of old metal bracket after rebonding and adhesive remnant.RESULTS: ① Shear bond strength: The

  20. An Intelligent Fleet Condition-Based Maintenance Decision Making Method Based on Multi-Agent

    Directory of Open Access Journals (Sweden)

    Bo Sun

    2012-01-01

    Full Text Available According to the demand for condition-based maintenance online decision making among a mission oriented fleet, an intelligent maintenance decision making method based on Multi-agent and heuristic rules is proposed. The process of condition-based maintenance within an aircraft fleet (each containing one or more Line Replaceable Modules based on multiple maintenance thresholds is analyzed. Then the process is abstracted into a Multi-Agent Model, a 2-layer model structure containing host negotiation and independent negotiation is established, and the heuristic rules applied to global and local maintenance decision making is proposed. Based on Contract Net Protocol and the heuristic rules, the maintenance decision making algorithm is put forward. Finally, a fleet consisting of 10 aircrafts on a 3-wave continuous mission is illustrated to verify this method. Simulation results indicate that this method can improve the availability of the fleet, meet mission demands, rationalize the utilization of support resources and provide support for online maintenance decision making among a mission oriented fleet.

  1. Nanoparticle-based capillary electroseparation of proteins in polymer capillaries under physiological conditions

    DEFF Research Database (Denmark)

    Nilsson, C.; Harwigsson, I.; Becker, K.

    2010-01-01

    Totally porous lipid-based liquid crystalline nanoparticles were used as pseudostationary phase for capillary electroseparation with LIF detection of proteins at physiological conditions using unmodified cyclic olefin copolymer capillaries (Topas (R), 6.7 cm effective length). In the absence...... at protein friendly conditions. The developed capillary-based method facilitates future electrochromatography of proteins on polymer-based microchips under physiological conditions and enables the initial optimization of separation conditions in parallel to the chip development....

  2. Laboratory-based electrical conductivity at Martian mantle conditions

    Science.gov (United States)

    Verhoeven, Olivier; Vacher, Pierre

    2016-12-01

    Information on temperature and composition of planetary mantles can be obtained from electrical conductivity profiles derived from induced magnetic field analysis. This requires a modeling of the conductivity for each mineral phase at conditions relevant to planetary interiors. Interpretation of iron-rich Martian mantle conductivity profile therefore requires a careful modeling of the conductivity of iron-bearing minerals. In this paper, we show that conduction mechanism called small polaron is the dominant conduction mechanism at temperature, water and iron content conditions relevant to Mars mantle. We then review the different measurements performed on mineral phases with various iron content. We show that, for all measurements of mineral conductivity reported so far, the effect of iron content on the activation energy governing the exponential decrease in the Arrhenius law can be modeled as the cubic square root of the iron content. We recast all laboratory results on a common generalized Arrhenius law for iron-bearing minerals, anchored on Earth's mantle values. We then use this modeling to compute a new synthetic profile of Martian mantle electrical conductivity. This new profile matches perfectly, in the depth range [100,1000] km, the electrical conductivity profile recently derived from the study of Mars Global Surveyor magnetic field measurements.

  3. Influence of adhesion promoters and curing-light sources on the shear bond strength of orthodontic brackets

    Directory of Open Access Journals (Sweden)

    Claudia Tavares Machado

    2012-01-01

    Conclusions: The conventional orthodontic adhesive presented higher bond strength than the nanofilled composite, although both materials interacted similarly to the teeth. The curing-light devices tested did not influence on bond strength of orthodontic brackets.

  4. Are Bonding Agents being Effective on the Shear Bond Strength of Orthodontic Brackets Bonded to the Composite?

    Directory of Open Access Journals (Sweden)

    Fahimeh Farzanegan

    2014-06-01

    Full Text Available Introduction: One of the clinical problems in orthodontics is the bonding of brackets tocomposite restorations. The aim of this study was to evaluate the shear bondstrength of brackets bonded to composite restorations using Excite. Methods:Forty brackets were bonded to composite surfaces, which were embedded inacrylic resin. One of the following four protocols was employed for surfacepreparation of the composite: group 1 37% phosphoric acid for 60 seconds, group2 roughening with a diamond bur plus 37% phosphoric acid for 60 seconds, group3 37% phosphoric acid for 60 seconds and the applying Excite®, group4 roughening with diamond bur plus 37% phosphoric acid for 60 seconds andapplying Excite®. Maxillary central brackets were bonded onto thecomposite prepared samples with Transbond XT. Shear Bond Strength (SBS wasmeasured by a universal testing machine. The ANOVA and Tukey test was utilizedfor data analysis. Results: There was a significant difference betweenthe four groups (P

  5. Energy Based Multiscale Modeling with Non-Periodic Boundary Conditions

    Science.gov (United States)

    2013-05-13

    subroutine and Python script are highlighted in Figure 14. 1. Reads the EVOL , or current element volume for all elements 2...Extracts the element stresses within the unit-cell RVE 3. Computes the volume average of the stresses based on the EVOL values 4. Using the volume

  6. Matter under Extreme Conditions: Advances Based on Static Compression

    Science.gov (United States)

    Hemley, Russell

    2008-04-01

    Current technological advances make it possible to perform experiments on materials at static or sustained conditions to multimegabar pressures (several hundred GPa) and several thousand degree (˜1 eV) temperatures. Densities of condensed matter can now be increased over an order of magnitude, causing novel transformations and new physical and chemical phenomena to occur. Growth in this area has been made possible by advances in diamond-anvil cell methods coupled with a wide range of probes, including x-ray diffraction, spectroscopy, inelastic scattering, radiography, and infrared spectroscopy using synchrotron radiation. Examples include investigations of dense hydrogen; transformations in molecular materials; novel ceramics; new types of superconductors, electronic, and magnetic materials; and liquids and amorphous materials. Particularly exciting are new developments in time resolved methods and coupling of static and dynamic compression techniques made possible by the creation of new large-scale facilities and novel technologies.

  7. Reliability-based condition assessment of steel containment and liners

    Energy Technology Data Exchange (ETDEWEB)

    Ellingwood, B.; Bhattacharya, B.; Zheng, R. [Johns Hopkins Univ., Baltimore, MD (United States). Dept. of Civil Engineering

    1996-11-01

    Steel containments and liners in nuclear power plants may be exposed to aggressive environments that may cause their strength and stiffness to decrease during the plant service life. Among the factors recognized as having the potential to cause structural deterioration are uniform, pitting or crevice corrosion; fatigue, including crack initiation and propagation to fracture; elevated temperature; and irradiation. The evaluation of steel containments and liners for continued service must provide assurance that they are able to withstand future extreme loads during the service period with a level of reliability that is sufficient for public safety. Rational methodologies to provide such assurances can be developed using modern structural reliability analysis principles that take uncertainties in loading, strength, and degradation resulting from environmental factors into account. The research described in this report is in support of the Steel Containments and Liners Program being conducted for the US Nuclear Regulatory Commission by the Oak Ridge National Laboratory. The research demonstrates the feasibility of using reliability analysis as a tool for performing condition assessments and service life predictions of steel containments and liners. Mathematical models that describe time-dependent changes in steel due to aggressive environmental factors are identified, and statistical data supporting the use of these models in time-dependent reliability analysis are summarized. The analysis of steel containment fragility is described, and simple illustrations of the impact on reliability of structural degradation are provided. The role of nondestructive evaluation in time-dependent reliability analysis, both in terms of defect detection and sizing, is examined. A Markov model provides a tool for accounting for time-dependent changes in damage condition of a structural component or system. 151 refs.

  8. Poisson Bracket for Fermion Fields: Correspondence Principle, Second Class Constraints and Hamilton-Jacobi equation

    CERN Document Server

    Leclerc, M

    2012-01-01

    We introduce a symmetric Poisson bracket that allows us to describe anticommuting fields on a classical level in the same way as commuting fields, without the use of Grassmann variables. By means of a simple example, we show how the Dirac bracket for the elimination of the second class constraints can be introduced, how the classical Hamiltonian equations can be derived and how quantization can be achieved through a direct correspondence principle. Finally, we show that the semiclassical limit of the corresponding Schroedinger equation leads back to the Hamilton-Jacobi equation of the classical theory. Summarizing, it is shown that the relations between classical and quantum theory are valid for fermionic fields in exactly the same way as in the bosonic case, and that there is no need to introduce anticommuting variables on a classical level.

  9. Evaluation of bond strength of brackets using various indirect bonding techniques

    Directory of Open Access Journals (Sweden)

    Piyush Bolya

    2017-01-01

    Full Text Available Introduction: Accurate bracket placement has been always an area of interest for all orthodontists. Different types of adhesives for indirect bonding techniques have been introduced recently. However, there is limited information regarding bond strength with these new materials. The aim of this study is to compare and evaluate the bond strength in various indirect bonding techniques when using different primers and adhesives. Materials and Methods: In this in vitro investigation, brackets were bonded to fifty extracted premolars which were divided into five groups (A–E of ten each. Results: The overall comparison of all the techniques produced comparable mean bond strengths that were well within the clinically acceptable range. Group D produced the highest bond strength in comparison to other groups followed by Group E, B, C, and A. Conclusion: In the present study, all the groups have shown shear bond strength of more than 7.8 MPa. Hence, all the five techniques are suitable for clinical use.

  10. Deproteinization of tooth enamel surfaces to prevent white spot lesions and bracket bond failure: A revolution in orthodontic bonding

    OpenAIRE

    Roberto Justus

    2016-01-01

    Orthodontic treatment success is jeopardized by the risk of development of white spot lesions (WSLs) around orthodontic brackets. Unfortunately, the formation of WSLs still remains a common complication during treatment in patients with poor oral hygiene. Nearly 75% of orthodontic patients are reported to develop enamel decalcification because of prolonged plaque retention around brackets. It is the orthodontist′s responsibility to minimize the risk of patients having enamel decalcifications ...

  11. Forest NPP estimation based on MODIS data under cloudless condition

    Institute of Scientific and Technical Information of China (English)

    CHEN LiangFu; GAO YanHua; LI Li; LIU QinHuo; GU XingFa

    2008-01-01

    Based on light-use efficiency model, an MODIS-derived daily net primary production (NPP) model was developed. In this model, a new model for the fraction of photosynthetically active radiation absorbed by vegetation (FPAR) is developed based on leaf area index (LAI) and albedo parameters, and a photosynthetically active radiation (PAR) is calculated from the combination of Bird's model with aerosol optical thickness and water vapor derived from cloud free MODIS images. These two models are integrated into our predicted NPP model, whose most parameters are retrieved from MODIS data. In order to validate our NPP model, the observed NPP in the Qianyanzhou station and the Changbai Mountains station are used to compare with our predicted NPP, showing that they are in good agreement. The NASA NPP products also have been downloaded and compared with the measurements, which shows that the NASA NPP products underestimated NPP in the Qianyanzhou station but overestimated in the Changbai Mountains station in 2004.

  12. A Data Warehouse to Support Condition Based Maintenance (CBM)

    Science.gov (United States)

    2005-05-01

    aircraft as well as failure and fault information for components. ELAS Data Management ELAS is fielded as a stand alone graphical user interface built...Additionally, ELAS could benefit from an intelligent graphical user interface that guides the user to make correct and logical entries based on the context...34ECS 2 LH EFAB Evap. Supply Temp. -3276.8 3276.8 Degrees Fahrenheit ECS 2 Condensor Inlet Temp. -3276.8 3276.8 Desees Fahrenheit ECS 2 Condenser

  13. Nonstationary conditional models for spatial data based on varying coefficients

    OpenAIRE

    Dreesman, J; Tutz, Gerhard

    1999-01-01

    The analysis of spatial data by means of Markov random fields usually is based on strict stationarity assumptions. Although these assumptions rarely hold, they are necessary in order to obtain parameter estimates. For Gaussian data the necessary assumptions are mean- and covariance stationarity. While simple techniques are available to deal with violations of mean stationarity, the same is not true for covariance stationarity. In order to handle mean nonstationarity as well as covariance nons...

  14. Performance of chromium nitride based coatings under plastic processing conditions

    OpenAIRE

    Cunha, l.; Andritschky, M.; Pischow, K.; Wang, Z.(Institute of High Energy Physics, Beijing, China); Zarychta, A.; Miranda, A. S.; A.M. Cunha

    2000-01-01

    Chromium nitride based coatings were produced in the form of monolithic and multilayer coatings, by DC and RF reactive magnetron sputtering. These coatings were deposited onto stainless steel and tool steel substrates. Chromium nitride coatings have;proved to be wear and corrosion resistant. The combination of these characteristics was necessary to protect surfaces during plastic processing. In order to select the best coatings, some mechanical and tribological tests were performed. Har...

  15. Effect of surface treatment of prefabricated teeth on shear bond strength of orthodontic brackets

    Science.gov (United States)

    Cumerlato, Marina; de Lima, Eduardo Martinelli; Osorio, Leandro Berni; Mota, Eduardo Gonçalves; de Menezes, Luciane Macedo; Rizzatto, Susana Maria Deon

    2017-01-01

    ABSTRACT Objective: The aim of this in vitro study was to evaluate and compare the effects of grinding, drilling, sandblasting, and ageing prefabricated teeth (PfT) on the shear bond strength (SBS) of orthodontic brackets, as well as the effects of surface treatments on the adhesive remnant index (ARI). Methods: One-hundred-ninety-two PfT were divided into four groups (n = 48): Group 1, no surface treatment was done; Group 2, grinding was performed with a cylindrical diamond bur; Group 3, two drillings were done with a spherical diamond bur; Group 4, sandblasting was performed with 50-µm aluminum oxide. Before the experiment, half of the samples stayed immersed in distilled water at 37oC for 90 days. Brackets were bonded with Transbond XT and shear strength tests were carried out using a universal testing machine. SBS were compared by surface treatment and by ageing with two-way ANOVA, followed by Tukey’s test. ARI scores were compared between surface treatments with Kruskal-Wallis test followed by Dunn’s test. Results: Surface treatments on PfT enhanced SBS of brackets (p< 0.01), result not observed with ageing (p= 0.45). Groups II, III, and IV showed higher SBS and greater ARI than the Group 1 (p< 0.05). SBS was greater in the groups 3 and 4 (drilling, sandblasting) than in the Group 2 (grinding) (p< 0.05). SBS and ARI showed a positive correlation (Spearman’s R2= 0.57; p< 0.05). Conclusion: Surface treatment on PfT enhanced SBS of brackets, however ageing did not show any relevance. Sandblasting and drilling showed greater SBS than grinding. There was a positive correlation between SBS and ARI.

  16. Transversal changes in dental arches from non-extraction treatment with self ligating brackets

    OpenAIRE

    Liliana Avila Maltagliati; Yasushi Inoue Myiahira; Liana Fattori; Leopoldino Capelozza Filho; Mauricio Cardoso

    2013-01-01

    OBJECTIVE: The present study aimed at analyzing, with the use of dental casts, the transverse changes of the upper and lower dental arches, after non-extraction orthodontic treatment, with self-ligating brackets. METHODS: The sample comprised 29 patients, all presenting Class I malocclusion with upper and lower crowding of at least 4 mm and treated only with a fixed appliance, without stripping, extraction or distalization. The dental casts were obtained before and after leveling with 0.019 x...

  17. Comparison of various products for the prevention of demineralization in the bracket environment

    OpenAIRE

    Coordes, Stefanie Louise

    2013-01-01

    Sealers and varnishes are used for the prophylaxis of demineralization in patients with multi-bracket treatment. Several agents have been recently introduced for this purpose. However, it remains unclear which one is more efficient and could be suggested as standard of care in this patient cohort. The aim of this study was to compare the long-term resistance of six different products against thermomechanical and chemical stress in vitro. The agents included in the study were the three fluorid...

  18. Truncated Nambu-Poisson Bracket and Entropy Formula for Multiple Membranes

    CERN Document Server

    Chu, Chong-Sun; Matsuo, Yutaka; Shiba, Shotaro

    2008-01-01

    We show that there exists a cut-off version of Nambu-Poisson bracket which defines a finite dimensional Lie 3-algebra. The algebra still satisfies the fundamental identity and thus produces N=8 supersymmetric BLG type equation of motion for multiple M2 branes. By counting the number of the moduli and the degree of freedom, we derive an entropy formula which scales as N^{3/2} as expected for the multiple M2 branes.

  19. Evaluation of enamel damages following orthodontic bracket debonding in fluorosed teeth bonded with adhesion promoter

    OpenAIRE

    Baherimoghadam, Tahreh; Akbarian, Sahar; Rasouli, Reza; Naseri, Navid

    2016-01-01

    Objective: To evaluate shear bond strength (SBS) of the orthodontic brackets bonded to fluorosed and nonfluorosed teeth using Light Bond with and without adhesion promoters and compare their enamel damages following debonding. Materials and Methods: In this study, 30 fluorosed (Thylstrup and Fejerskov Index = 4?5) and 30 nonfluorosed teeth were randomly distributed between two subgroups according to the bonding materials: Group 1, fluorosed teeth bonded with Light Bond; Group 2, fluorosed tee...

  20. Enamel Surface Roughness after Debonding of Orthodontic Brackets and Various Clean-Up Techniques

    OpenAIRE

    2013-01-01

    Objective: This study aimed to evaluate enamel roughness after adhesive removal using different burs and an Er:YAG laser. Materials and Methods: The buccal surfaces of forty human premolars were sealed by two layers of nail varnish, except for a circular area of 3 mm in diameter on the middle third. The enamel surfaces were initially subjected to profilometry analysis and four parameters of surface irregularity (Ra, Rq, Rt and Rz) were recorded. Following bracket bonding and debonding, adhesi...

  1. Physical and adhesive properties of dental enamel after radiotherapy and bonding of metal and ceramic brackets.

    Science.gov (United States)

    Santin, Gabriela Cristina; Palma-Dibb, Regina Guenka; Romano, Fábio Lourenço; de Oliveira, Harley Francisco; Nelson Filho, Paulo; de Queiroz, Alexandra Mussolino

    2015-08-01

    The increasing success rates for cancer patients treated with radiotherapy and the frequent occurrence of tooth loss during treatment have led to an increased demand for orthodontic treatment after radiotherapy. The aim of this study was to evaluate tooth enamel of irradiated teeth after the bonding and debonding of metal and ceramic brackets. Ten permanent molars were cut into enamel fragments measuring 1 mm(2) and divided into an irradiated group (total dose of 60 Gy) and a nonirradiated group. The fragments were subjected to microshear testing to evaluate whether radiotherapy altered the strength of the enamel. Furthermore, 90 prepared premolars were divided into 6 groups and subgroups (n = 15): group 1, nonirradiated and nonaged; group 2, nonirradiated and aged (thermal cycled); group 3, irradiated and aged; each group was divided into 2 subgroups: metallic and ceramic brackets. After thermal cycling and radiotherapy, the brackets were bonded onto the specimens with Transbond XT (3M Unitek, Monrovia, Calif). After 24 hours, the specimens were subjected to the shear tests. Images of the enamel surfaces were classified using the adhesive remnant index. The composite resin-enamel interface was also evaluated. Enamel fragments subjected to radiation had lower strength than did the nonirradiated samples (P enamel interface, resin tags were more extensive on irradiated tooth enamel. Radiation decreased tooth enamel strength, and the specimens treated with radiotherapy had higher frequencies of adhesive failure between the bracket and the composite resin as well as more extensive tags. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  2. Are self-ligating brackets related to less formation of Streptococcus mutans colonies? A systematic review

    Directory of Open Access Journals (Sweden)

    Leonard Euler Andrade Gomes do Nascimento

    2014-01-01

    Full Text Available OBJECTIVE: To verify, by means of a systematic review, whether the design of brackets (conventional or self-ligating influences adhesion and formation of Streptococcus mutans colonies. METHODS: Search strategy: four databases (Cochrane Central Register of Controlled Trials, Ovid ALL EMB Reviews, PubMed and BIREME were selected to search relevant articles covering the period from January 1965 to December 2012. Selection Criteria: in first consensus by reading the title and abstract. The full text was obtained from publications that met the inclusion criteria. Data collection and analysis: Two reviewers independently extracted data using the keywords: conventional, self-ligating, biofilm, Streptococcus mutans, and systematic review; and independently evaluated the quality of the studies. In case of divergence, the technique of consensus was adopted. RESULTS: The search strategy resulted in 1,401 articles. The classification of scientific relevance revealed the high quality of the 6 eligible articles of which outcomes were not unanimous in reporting not only the influence of the design of the brackets (conventional or self-ligating over adhesion and formation of colonies of Streptococcus mutans, but also that other factors such as the quality of the bracket type, the level of individual oral hygiene, bonding and age may have greater influence. Statistical analysis was not feasible because of the heterogeneous methodological design. CONCLUSIONS: Within the limitations of this study, it was concluded that there is no evidence for a possible influence of the design of the brackets (conventional or self-ligating over colony formation and adhesion of Streptococcus mutans.

  3. Are self-ligating brackets related to less formation of Streptococcus mutans colonies? A systematic review

    OpenAIRE

    Leonard Euler Andrade Gomes do Nascimento; Margareth Maria Gomes de Souza; Angela Rita Pontes Azevedo; Lucianne Cople Maia

    2014-01-01

    OBJECTIVE: To verify, by means of a systematic review, whether the design of brackets (conventional or self-ligating) influences adhesion and formation of Streptococcus mutans colonies. METHODS: Search strategy: four databases (Cochrane Central Register of Controlled Trials, Ovid ALL EMB Reviews, PubMed and BIREME) were selected to search relevant articles covering the period from January 1965 to December 2012. Selection Criteria: in first consensus by reading the title and abstract. The...

  4. Carbon dioxide laser and bonding materials reduce enamel demineralization around orthodontic brackets.

    Science.gov (United States)

    de Souza-e-Silva, Cíntia Maria; Parisotto, Thaís Manzano; Steiner-Oliveira, Carolina; Kamiya, Regianne Umeko; Rodrigues, Lidiany Karla Azevedo; Nobre-dos-Santos, Marinês

    2013-01-01

    Altering the structure of the enamel surface around the orthodontic bracket by reducing its content of carbonate and phosphate resulting from application of CO(2) laser may represent a more effective strategy in preventing caries in this region. This study aimed at determining whether irradiation with a CO(2) laser combined with fluoride-releasing bonding material could reduce enamel demineralization around orthodontic brackets subjected to cariogenic challenge. Ninety bovine enamel slabs were divided into five groups (n = 18): non-inoculated brain-heart infusion broth group, non-fluoride-releasing composite resin (NFRCR--control group), resin-modified glass ionomer cement (RMGIC), CO(2) laser + Transbond (L+NFRCR) and CO(2) laser + Fuji (L+RMGIC). Slabs were submitted to a 5-day microbiological caries model. The Streptococcus mutans biofilm formed on the slabs was biochemically and microbiologically analysed, and the enamel Knoop hardness number (KHN) around the brackets was determined. The data were analysed by ANOVA and Tukey tests (α = 0.05). Biochemical and microbiological analyses of the biofilm revealed no statistically significant differences among the groups. Lased groups presented the highest KHN means, which statistically differed from NFRCR; however, no difference was found between these lased groups. RMGIC did not differ from NFRCR which presented the lowest KHN mean. The CO(2) laser (λ = 10.6 μm; 10.0 J/cm(2) per pulse) use with or without F-bonding materials was effective in inhibiting demineralization around orthodontic brackets. However, no additional effect was found when the enamel was treated with the combination of CO(2) laser and an F-releasing material.

  5. Fluoride-Releasing Materials to Prevent White Spot Lesions around Orthodontic Brackets: A Systematic Review

    OpenAIRE

    Nascimento,Patrícia Layane de Menezes Macêdo; Fernandes,Micaelle Tenório Guedes; de Figueiredo, Fabricio Eneas Diniz; Faria-e-Silva,André Luis

    2016-01-01

    Abstract The relation between orthodontic fixed appliances use and enamel demineralization is well established. Different preventive approaches have been suggested to this problem, but controversy remains about which is the best. The aim of this study was to perform a systematic review of clinical trials that investigated the effectiveness of materials containing fluorides to lute brackets or cover the bonding interface in order to inhibit the development and progression of white spot lesions...

  6. Effect of varying etching times on the bond strength of ceramic brackets.

    Science.gov (United States)

    Olsen, M E; Bishara, S E; Boyer, D B; Jakobsen, J R

    1996-04-01

    Damage to the enamel surface when debonding orthodontic ceramic brackets has been a clinical concern. Ideally, bond failure at the bracket-adhesive interface should occur without damaging the enamel surface. The purpose of this study was to determine the shear bond strength and debonding failure modes of ceramic brackets with varying etching times. Sixty freshly extracted human premolars were pumiced and divided into six groups of 10 teeth. Each group was assigned an etching time interval of either 30, 20, 15, 10, 5, or 0 seconds with 37% phosphoric acid. Ceramic orthodontic brackets were bonded to each etched tooth by using the same orthodontic bonding system. The teeth were mounted in phenolic rings and stored in deionized water at 37 degrees C for 48 hours. A Zwick universal testing machine (Zwick GmbH and Co., Ulm, Germany) was used to determine shear bond strengths. The residual adhesive on the enamel surface was evaluated with the Adhesive Remnant Index. The results of the analysis of variance indicated that there were significant differences in bond strengths between the various etching times (p=0.0001). The Duncan multiple range test revealed that the 5-second and no etch group exhibited significantly lower bond strengths. The results of the Chi square test evaluating the residual adhesives on the enamel surface also revealed significant differences (p=0.0001). However, when the 5- and 0-second groups were dropped from the test, the Chi square test revealed no significant differences between the 30-, 20-, 15-, and 10-second groups (p=0.211). In conclusion, decreasing etching time between 30 and 10 seconds does not significantly affect either bond strength or the site of bond failure.

  7. Effect of dental bleaching after bracket bonding and debonding using three different adhesive systems

    Directory of Open Access Journals (Sweden)

    Lucianna de Oliveira Gomes

    2013-04-01

    Full Text Available OBJECTIVE: To evaluate the influence of bonding and debonding of orthodontic brackets on dental in-home bleaching, taking into account three different adhesive systems. METHODS: Forty-four bovine incisors were divided into four groups according to the primer system used for orthodontic bracket bonding. Following the debonding of orthodontic brackets, the teeth were stored in staining solution for 96 hours. Then, teeth were whitened using 10% carbamide peroxide for two weeks at a 6-hour-a-day regime. Standardized digital photographs were taken at the following intervals: T0 (initial; T1 (after debonding; T2 (after pigmentation; T3, T4 and T5 representing 1, 7, and 14 days of bleaching. Repeatability and stability tests were carried out to check the method accuracy. Images were analyzed using Adobe Photoshop 7.0 software considering (L*a*b*color coordinate values and a modified color difference total (Δ;E'. RESULTS: The results of this study (ANOVA and Tukey; p < 0.01 demonstrated that after 7 days of bleaching, experimental groups showed significantly less teeth whitening compared to the control group. However, there were no significant color differences between the groups after 14 days, according to values of lightness (L*. CONCLUSIONS: Regardless of the adhesive primer system applied, bonding and debonding of orthodontic brackets alters the outcome of tooth whitening in the first 7 days of bleaching, however it has no influence on the whitening of the dental structure after 14 days of in-home dental bleaching with 10% carbamide peroxide.

  8. Triangulation Algorithm Based on Empty Convex Set Condition

    Directory of Open Access Journals (Sweden)

    Klyachin Vladimir Aleksandrovich

    2015-11-01

    Full Text Available The article is devoted to generalization of Delaunay triangulation. We suggest to consider empty condition for special convex sets. For given finite set P ⊂ Rn we shall say that empty condition for convex set B ⊂ Rn is fullfiled if P ∩ B = P ∩ ∂B. Let Φ = Φα, α ∈ A be a family of compact convex sets with non empty inner. Consider some nondegenerate simplex S ⊂ Rn with vertexes p0,...,pn. We define the girth set B(S ∈ Φ if qi ∈ ∂B(S, i = 0, 1, ..., n. We suppose that the family Φ has the property: for arbitrary nondegenerate simplex S there is only one the girth set B(S. We prove the following main result. Theorem 1. If the family Φ = Φα, α ∈ A of convex sets have the pointed above property then for the girth sets it is true: 1. The set B(S is uniquely determined by any simplex with vertexes on ∂B(S. 2. Let S1, S2 be two nondegenerate simplexes such that B(S1 ≠ B(S2. If the intersection B(S1 ∩ B(S2 is not empty, then the intersection of boundaries B(S1, B(S2 is (n − 2-dimensional convex surface, lying in some hyperplane. 3. If two simplexes S1 and S2 don’t intersect by inner points and have common (n − 1-dimensional face G and A, B are vertexes don’t belong to face G and vertex B of simplex B(S2 such that B ∉ B(S1 then B(S2 does not contain the vertex A of simplex S1. These statements allow us to define Φ-triangulation correctly by the following way. The given triangulation T of finite set P ⊂ Rn is called Φ-triangulation if for all simlex S ∈ T the girth set B(S ∈ Φ is empty. In the paper we give algorithm for construct Φ-triangulation arbitrary finite set P ⊂ Rn. Besides we describe examples of families Φ for which we prove the existence and uniqueness of girth set B(S for arbitrary nondegenerate simplex S.

  9. Shear bond strength of metal brackets to feldspathic porcelain treated by Nd:YAG laser and hydrofluoric acid.

    Science.gov (United States)

    Hosseini, Mohammad Hashem; Sobouti, Farhad; Etemadi, Ardavan; Chiniforush, Nasim; Shariati, Mahsa

    2015-02-01

    Adult orthodontic treatment requires bonding orthodontic attachment to dental restorations. Ceramics are commonly used as esthetic restorative materials for the crowns and bridges. The present study evaluated the shear bond strength of metal orthodontic brackets to the feldspathic porcelain surfaces following conditioning by different powers of neodymium-doped yttrium aluminum garnet (Nd:YAG) laser and hydrofluoric acid as a conventional method. Seventy-two glazed porcelain samples were prepared and randomly attributed to six equal groups of 12. In the conventional hydrofluoric (HF) group, the specimens were etched by 9.6% hydrofluoric acid for 4 min. In laser groups, samples were conditioned by 0.75-, 1-, 1.25-, 1.5-, and 2-W Nd:YAG laser for 10 s. Metal brackets were bonded to porcelain samples and after being stored in distilled water for 24 h, they were subjected to thermocycling for 500 cycles. The debonding was carried out by a Zwick testing machine. The data were statistically analyzed by ANOVA and Tamhane multiple comparisons tests. The mean ± SD of the shear bond strength in the laser group 0.75, 1, 1.25, 1.5, and 2 W and HF group was 2.2 ± 0.9, 4.2 ± 1.1, 4.9 ± 2.4, 7 ± 1.7, 9.6 ± 2.7, and 9.4 ± 2.5, respectively. Together with the increased power of laser, the mean shear bond strength was increased continuously and no significant differences were found between the HF group and the laser groups with power of 1.5 or 2 W. Also, there was no significant difference between all test groups in ARI scores. There was no significant difference between bond strength of laser groups with power of 1.5 and 2 W and HF-etched group. So, Nd:YAG laser with appropriate parameters can be used as an alternative method for porcelain etching.

  10. Dye-enhanced laser fluorescence detection of caries lesions around brackets.

    Science.gov (United States)

    Alencar, Cássio José Fornazari; Braga, Mariana Minatel; de Oliveira, Elisabeth; Nicolau, José; Mendes, Fausto Medeiros

    2009-11-01

    The aim was to evaluate the performance of DIAGNOdent [laser fluorescence(LF) and LFpen] devices enhanced by fluorescent dye in detecting mineral loss around brackets and comparing the inhibitory effect of bonding material on artificial demineralization, and to verify whether LF methods show the same trends of mineral loss. Brackets were bonded to premolar halves with Fuji Ortho LC, Transbond XT, and Ortho Glass LC cements (n = 15). The teeth were soaked in demineralizing solution (pH = 4.8) for 16 days. Mineral loss was calculated by atomic emission spectrometry, and lesions were measured with LF devices with dye [tetrakis N-methylpyridyl porphyrin (TMPyP)]. Groups were compared with regard to LF readings and mineral loss, and performance of caries detection was calculated. Higher mineral loss and LF-TMPyP values occurred in the resin group. LFpen-TMPyP readings were significantly higher in the demineralized groups. Correlation was observed between mineral loss and LF measurements. LF methods are capable of identifying lower demineralization around brackets bonded with resin-modified glass ionomer cements.

  11. Bonding brackets on white spot lesions pretreated by means of two methods

    Science.gov (United States)

    Vianna, Julia Sotero; Marquezan, Mariana; Lau, Thiago Chon Leon; Sant'Anna, Eduardo Franzotti

    2016-01-01

    Abstract Objective: The aim of this study was to evaluate the shear bond strength (SBS) of brackets bonded to demineralized enamel pretreated with low viscosity Icon Infiltrant resin (DMG) and glass ionomer cement (Clinpro XT Varnish, 3M Unitek) with and without aging. Methods: A total of 75 bovine enamel specimens were allocated into five groups (n = 15). Group 1 was the control group in which the enamel surface was not demineralized. In the other four groups, the surfaces were submitted to cariogenic challenge and white spot lesions were treated. Groups 2 and 3 were treated with Icon Infiltrant resin; Groups 4 and 5, with Clinpro XT Varnish. After treatment, Groups 3 and 5 were artificially aged. Brackets were bonded with Transbond XT adhesive system and SBS was evaluated by means of a universal testing machine. Statistical analysis was performed by one-way analysis of variance followed by Tukey post-hoc test. Results: All groups tested presented shear bond strengths similar to or higher than the control group. Specimens of Group 4 had significantly higher shear bond strength values (p < 0.05) than the others. Conclusion: Pretreatment of white spot lesions, with or without aging, did not decrease the SBS of brackets. PMID:27275613

  12. Rebonding of orthodontic brackets. Part II, an XPS and SEM study.

    Science.gov (United States)

    Montasser, Mona A; Drummond, James L; Roth, John R; Al-Turki, Lulwa; Evans, Carla A

    2008-05-01

    The hypothesis of this two-part study is that adhesive systems for bonding orthodontic brackets (ie, two self-etch primers [Transbond and M-Bond] and a conventional phosphoric acid etch [Rely-a-Bond]) would show a difference with respect to rebonded enamel surface morphology and chemical composition. This study examined the enamel surface before and after debonding with scanning electron microscopy and the enamel surface chemical composition for the elements Ca, P, O, F, Si, and C using x-ray photoelectron spectroscopy. The etching of the two self-etch groups is less aggressive and less uniform than that of phosphoric acid. The change in the concentration of C indicated that the separation of the bracket from the enamel surface is at the resin-enamel interface for the phosphoric acid-etched adhesive and a mixed mode involving the enamel-resin-bracket interfaces for the self-etching systems. F release appears to occur for Transbond but not for M-Bond. The results confirm the original hypothesis that differences in adhesive systems are manifested in less aggressive etches and less adhesive left on the enamel surface for the self-etching adhesive systems.

  13. Preparation and antimicrobial assay of ceramic brackets coated with TiO2 thin films

    Science.gov (United States)

    Cao, Shuai; Wang, Ye; Cao, Lin; Wang, Yu; Lin, Bingpeng; Lan, Wei

    2016-01-01

    Objective Different methods have been utilized to prevent enamel demineralization and other complications during orthodontic treatment. However, none of these methods can offer long-lasting and effective prevention of orthodontic complications or interventions after complications occur. Considering the photocatalytic effect of TiO2 on organic compounds, we hoped to synthesize a novel bracket with a TiO2 thin film to develop a photocatalytic antimicrobial effect. Methods The sol-gel dip coating method was used to prepare TiO2 thin films on ceramic bracket surfaces. Twenty groups of samples were composed according to the experimental parameters. Crystalline structure and surface morphology were characterized by X-ray diffraction and scanning electron microscopy, respectively; film thickness was examined with a surface ellipsometer. The photocatalytic properties under ultraviolet (UV) light irradiation were analyzed by evaluating the degradation ratio of methylene blue (MB) at a certain time. Antibacterial activities of selected thin films were also tested against Lactobacillus acidophilus and Candida albicans. Results Films with 5 coating layers annealed at 700℃ showed the greatest photocatalytic activity in terms of MB decomposition under UV light irradiation. TiO2 thin films with 5 coating layers annealed at 700℃ exhibited the greatest antimicrobial activity under UV-A light irradiation. Conclusions These results provide promising guidance in prevention of demineralization by increasing antimicrobial activities of film coated brackets. PMID:27226960

  14. Microhardness of enamel adjacent to orthodontic brackets after CO2 laser irradiation and fluoride application.

    Science.gov (United States)

    Stangler, Leonardo Pucci; Romano, Fábio Lourenço; Shirozaki, Mariana Umekita; Galo, Rodrigo; Afonso, Alessandra Marques Correa; Borsatto, Maria Cristina; Matsumoto, Mírian Aiko Nakane

    2013-01-01

    This study evaluated the effectiveness of carbon dioxide (CO2) laser combined or not with fluoride application on the surface microhardness of enamel adjacent to orthodontic brackets. Fifteen human molars were selected from which 30 enamel fragments measuring 4 mm2 were obtained. The fragments were embedded in PCV tubes with acrylic resin and prepared using water abrasive paper, felt disks and alumina. Orthodontic brackets cut in half were bonded to enamel and 3 microhardness readings were performed on the adjacent surface, as follows: initial, after cariogenic challenge and final. The specimens were divided into the following 3 groups (n=10): Group C: control, Group L: irradiated with CO2 laser, and Group FL: topical fluoride application and CO2 laser irradiation. After initial reading, the specimens were placed in a demineralizing solution for 32 h and the second reading was to verify if demineralization was uniform in all groups. After the treatments, the specimens were submitted to DES-RE cycling for 8 days followed by final surface microhardness reading. The data were analyzed statistically using ANOVA and Duncan test (α=0.05). At the final measurement Group FL obtained higher microhardness value than Groups C and L (pCO2 laser around orthodontic brackets combined or not with topical fluoride application was effective to increase the surface microhardness of enamel.

  15. The effect of topical fluoride varnish on the shear bond strength of orthodontic brackets.

    Science.gov (United States)

    Nhan, Ruby Thuy-Huy; Xu, Xaoming; Yu, Qingzhao; Ballard, Richard; Armbruster, Paul

    2015-05-01

    The present study examined the effect of topical fluoride treatment on the shear bond strength (SBS) of orthodontic brackets using single-dose fluoride varnishes and assessed according to different post-application times and the pattern of debond. Of the 105 extracted human mandibular premolars used in the study, 70 were subjected to the SBS test and the remaining 35 to the Adhesive Remnant Index (ARI) test. The teeth were divided into a control group and six test groups: Kolorz ClearShield 5% NaFl varnish Day 1, 8, and 15; and Vanish 5% NaFl varnish Day 1, 8, and 15. The samples were coated with their respective varnish, following which, brackets were bonded. Each specimen was subjected to a shear force in a universal testing machine until failure. Data were analysed using the analysis of variance (ANOVA). At all time intervals, the mean SBS of the Vanish groups was not significantly different from the control group, and the shear strength in the ClearShield groups was significantly higher than the control and Vanish groups, except at Day 8 (no difference). For the same bonding material, there was no significant difference in mean SBS over different time intervals. ARI scores showed no significant difference between the groups. The application of single-dose fluoride varnish, irrespective of the length of time between the fluoride treatment and bonding procedure, does not negatively affect the shear bond strength of orthodontic brackets.

  16. Bonding brackets on white spot lesions pretreated by means of two methods

    Directory of Open Access Journals (Sweden)

    Julia Sotero Vianna

    2016-04-01

    Full Text Available Abstract Objective: The aim of this study was to evaluate the shear bond strength (SBS of brackets bonded to demineralized enamel pretreated with low viscosity Icon Infiltrant resin (DMG and glass ionomer cement (Clinpro XT Varnish, 3M Unitek with and without aging. Methods: A total of 75 bovine enamel specimens were allocated into five groups (n = 15. Group 1 was the control group in which the enamel surface was not demineralized. In the other four groups, the surfaces were submitted to cariogenic challenge and white spot lesions were treated. Groups 2 and 3 were treated with Icon Infiltrant resin; Groups 4 and 5, with Clinpro XT Varnish. After treatment, Groups 3 and 5 were artificially aged. Brackets were bonded with Transbond XT adhesive system and SBS was evaluated by means of a universal testing machine. Statistical analysis was performed by one-way analysis of variance followed by Tukey post-hoc test. Results: All groups tested presented shear bond strengths similar to or higher than the control group. Specimens of Group 4 had significantly higher shear bond strength values (p < 0.05 than the others. Conclusion: Pretreatment of white spot lesions, with or without aging, did not decrease the SBS of brackets.

  17. Microleakage under Orthodontic Metal Brackets Bonded with Three Different Bonding Techniques with/without Thermocycling

    Directory of Open Access Journals (Sweden)

    Berahman Sabzevari

    2013-12-01

    Full Text Available Introduction: The aim of this study was to compare the microleakage of beneath the orthodontic brackets bonded with 3 different bonding techniques and evaluate the effect of thermocycling. Methods: One hundred and twenty premolars were randomly divided into 6 groups, received the following treatment: group 1: 37% phosphoric acid gel+Unite primer+Unite adhesive, group 2: 37% phosphoric acid gel+ Transbond XT primer+Transbond XT adhesive, group 3: Transbond plus Self Etching Primer (TSEP+Transbond XT adhesive. Groups 4, 5, and 6 were similar to groups 1, 2, and 3, respectively. Evaluation of microleakage was done following to thermocycling test. After bonding, the specimens were sealed with nail varnish except for 1 mm around the brackets and then stained with 0.5% basic fuchsine. The specimens were sectioned at buccolingual direction in 2 parallel planes and evaluated under a stereomicroscope to determine the amount of microleakage at bracket-adhesive and adhesive-enamel interfaces from gingival and occlusal margins. Results: Microleakage was observed in all groups, and increased significantly after thermocycling at some interfaces of Unite adhesive group and conventional etching+Transbond XT adhesive group, but the increase was not significant in any interface of TSEP group. With or without thermocycling, TSEP displayed more microleakage than other groups. In most groups, microleakage at gingival margin was significantly higher than occlusal margin. Conclusion: Thermocycling and type of bonding technique significantly affect the amount of microleakage.

  18. Photoacoustic spectroscopy based evaluation of breast cancer condition

    Science.gov (United States)

    Priya, Mallika; Chandra, Subhas; Rao, Bola Sadashiva S.; Ray, Satadru; Shetty, Prashanth; Mathew, Stanley; Mahato, Krishna Kishore

    2015-02-01

    Photoacoustic spectroscopy, a hybrid of optics and acoustics has been gaining popularity in the biomedical field very fast. The main aim in the present study was to apply this technique to detect and distinguish breast tumor tissues from normal and hence develop a tool for clinical applications. There were 224 photoacoustic spectra recorded from 28 normal and 28 breast tumor tissues using PZT detector at 281nm pulsed laser excitations from Nd-YAG laser pumped frequency doubled dye laser system. The recorded time domain photoacoustic spectra were fast Fourier transformed into frequency domain patterns in the frequency region 0-1250kHz and from each pattern, 7 features (mean, median, mode, variance, standard deviation, area under the curve & spectral residual after fitting with 10th degree polynomial) were extracted using MATLAB algorithms. These features were then tested for their significance between normal and malignant conditions using Student T-test and two of them (variance, std. deviation) showing significant variation were selected for further discrimination analysis using supervised quadratic discriminate analysis (QDA). In QDA, 60 spectra from each of the normal and malignant were used for making the respective calibration sets and the remaining 52 spectra from each were used for the validation. The performance of the analysis tested for the frequency region 406.25 - 625.31 kHz, showed specificity and sensitivity values of 100% and 88.46% respectively suggesting possible application of the technique in breast tumor detection.

  19. Influences of bracket bonding on mutans streptococcus in plaque detected by real time fluorescence-quantitative polymerase chain reaction

    Institute of Scientific and Technical Information of China (English)

    AI Hong; LU Hong-fei; LIANG Huan-you; WU Jian; LI Ruo-lan; LIU Guo-ping; XI Yun

    2005-01-01

    Background Enamel demineralization occurs frequently during orthodontic treatment. In this study, we evaluated the changes of the density of mutans streptococcus (MS) in plaque after bracket bonding and using fluoride adhesive on maxillary incisors by real time fluorescence-quantitative polymerase chain reaction (RT-FQ PCR).Methods The study was designed as a self-paired test. Brackets were bonded with fluoride adhesive on the left side, while non-fluoride adhesive on the right side for each patient. Plaque samples were taken from the surfaces around the brackets of four maxillary incisors before brackets bonding and after the bonding 4 weeks later. The amount of MS was measured by RT-FQ PCR. The data obtained were analyzed statistically using the SPSS 11.5 version and the alpha level was set at 0.05 (2-tailed).Results The amount of MS in plaque increased significantly after bracket bonding (P0.05), and among the incisors using and not using fluoride adhesive (P>0.05).Conclusions The increase of the density of MS in plaque after bracket bonding is one of the etiological factors for enamel demineralization in orthodontic patients. The result of this study did not support what we observed clinically that the incidence of enamel demineralization for lateral incisors was higher than that for central incisors. Using fluoride adhesive for bonding did not affect the amount of MS in plaque in our study. Further study is needed.

  20. Damage of the Interface Between an Orthodontic Bracket and Enamel - the Effect of Some Elastic Properties of the Adhesive Material

    Science.gov (United States)

    Durgesh, B. H.; Alkheraif, A. A.; Al Sharawy, M.; Varrela, J.; Vallittu, P. K.

    2016-01-01

    The aim of this study was to investigate the magnitude of debonding stress of an orthodontic bracket bonded to the enamel with resin systems having different elastic properties. For the same purpose, sixty human premolars were randomly divided into four groups according to the adhesive system used for bonding brackets: G Fix flowable resin (GFI) with Everstick NET (ESN), GFI, G Aenial Universal Flow (GAU) with ESN, and GAU. The brackets were stressed in the occlusogingival direction on a universal testing machine. The values of debonding load and displacement were determined at the point of debonding. The elastic modulus of the tested materials was determined using nanoindentation. An analysis of variance showed a significant difference in the loads required to debond the bracket among the groups tested. The GAU group had the highest elastic modulus, followed by the GFI and ESN groups. ARI (Adhesive Remnant Index) scores demonstrated more remnants of the adhesive material on the bracket surface with adhesives having a higher elastic modulus. Taking into consideration results of the present in-vitro study, it can be concluded that the incorporation of a glass-fiber-reinforced composite resin (FRC) with a low elastic modulus between the orthodontic bracket and enamel increases the debonding force and strain more than with adhesive systems having a higher elastic modulus.

  1. Forest NPP estimation based on MODIS data under cloudless condition

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Based on light-use efficiency model, an MODIS-derived daily net primary production (NPP) model was developed. In this model, a new model for the fraction of photosynthetically active radiation absorbed by vegetation (FPAR) is developed based on leaf area index (LAI) and albedo parameters, and a pho- tosynthetically active radiation (PAR) is calculated from the combination of Bird’s model with aerosol optical thickness and water vapor derived from cloud free MODIS images. These two models are inte- grated into our predicted NPP model, whose most parameters are retrieved from MODIS data. In order to validate our NPP model, the observed NPP in the Qianyanzhou station and the Changbai Mountains station are used to compare with our predicted NPP, showing that they are in good agreement. The NASA NPP products also have been downloaded and compared with the measurements, which shows that the NASA NPP products underestimated NPP in the Qianyanzhou station but overestimated in the Changbai Mountains station in 2004.

  2. ANN Based Tool Condition Monitoring System for CNC Milling Machines

    Directory of Open Access Journals (Sweden)

    Mota-Valtierra G.C.

    2011-10-01

    Full Text Available Most of the companies have as objective to manufacture high-quality products, then by optimizing costs, reducing and controlling the variations in its production processes it is possible. Within manufacturing industries a very important issue is the tool condition monitoring, since the tool state will determine the quality of products. Besides, a good monitoring system will protect the machinery from severe damages. For determining the state of the cutting tools in a milling machine, there is a great variety of models in the industrial market, however these systems are not available to all companies because of their high costs and the requirements of modifying the machining tool in order to attach the system sensors. This paper presents an intelligent classification system which determines the status of cutt ers in a Computer Numerical Control (CNC milling machine. This tool state is mainly detected through the analysis of the cutting forces drawn from the spindle motors currents. This monitoring system does not need sensors so it is no necessary to modify the machine. The correct classification is made by advanced digital signal processing techniques. Just after acquiring a signal, a FIR digital filter is applied to the data to eliminate the undesired noisy components and to extract the embedded force components. A Wavelet Transformation is applied to the filtered signal in order to compress the data amount and to optimize the classifier structure. Then a multilayer perceptron- type neural network is responsible for carrying out the classification of the signal. Achieving a reliability of 95%, the system is capable of detecting breakage and a worn cutter.

  3. Dynamic Simulation of Torsion Beam Bracket%扭力梁安装支座动力学仿真分析

    Institute of Scientific and Technical Information of China (English)

    王亚南; 宋纪侠; 王彦

    2012-01-01

    In the paper,some torsion beam bracket is simulated with the help of dynamics software Adams/ride and Adams/car.According to contrast,we can conclude that the analysis result of torsion beam bracket in rear suspension assembly Adams/car is the same as that in whole vehicle Adams/ride.And then rear suspension assembly is simulated under different work conditions,and then the main cause of carling outrigger breakage is found out.%运用Adams/ride和Adams/car软件对某车型扭力梁安装支座进行动力学仿真分析。对比分析可知,运用Adams/car对后悬架系统进行扭力梁安装支座的受力分析基本能够模拟其在整车状态下Adams/ride的受力分析。进而对后悬架系统在不同工况下进行受力分析,找出纵梁舷外支架开裂的主要原因。

  4. 电阻点焊电动机支架断裂失效分析%Fracture failure analysis of resistance spot welding motor bracket

    Institute of Scientific and Technical Information of China (English)

    王亚婷; 徐越兰; 刘敏; 李文健

    2011-01-01

    分析了电阻点焊电动机支架高频振动破坏试样的失效原因.通过焊材成分分析、断口形貌分析和微观金相组织分析,结果表明,固定电动机支架发生断裂的原因是由于焊接工艺不当所致.因此在焊接过程中应该适当改变焊接工艺参数,调整焊接规范.%Fracture failure analysis was made on resistance spot welding motor bracket test specimens which were destroyed by the high-frequency vibration.Component analysis of weld materials, macroscopic analysis of fracture morphology and microscopic analysis of the microstructure show that the reason why the fixed motor bracket was broken was due to improper welding.Therefore, during the welding process the welding parameters should be changed appropriately, and the welding conditions should be adjusted too.

  5. A trade based view on casino taxation: market conditions.

    Science.gov (United States)

    Li, Guoqiang; Gu, Xinhua; Wu, Jie

    2015-06-01

    This article presents a trade based theory of casino taxation along with empirical evidence found from Macao as a typical tourism resort. We prove that there is a unique optimum gaming tax in a particular market for casino gambling, argue that any change in this tax is engendered by external demand shifts, and suggest that the economic rent from gambling legalization should be shared through such optimal tax between the public and private sectors. Our work also studies the tradeoff between economic benefits and social costs arising from casino tourism, and provides some policy recommendations for the sustainable development of gaming-led economies. The theoretical arguments in this article turn out to be consistent with empirical observations on Macao realities over the recent decade.

  6. Reproducing stone monument photosynthetic-based colonization under laboratory conditions.

    Science.gov (United States)

    Miller, Ana Zélia; Laiz, Leonila; Gonzalez, Juan Miguel; Dionísio, Amélia; Macedo, Maria Filomena; Saiz-Jimenez, Cesareo

    2008-11-01

    In order to understand the biodeterioration process occurring on stone monuments, we analyzed the microbial communities involved in these processes and studied their ability to colonize stones under controlled laboratory experiments. In this study, a natural green biofilm from a limestone monument was cultivated, inoculated on stone probes of the same lithotype and incubated in a laboratory chamber. This incubation system, which exposes stone samples to intermittently sprinkling water, allowed the development of photosynthetic biofilms similar to those occurring on stone monuments. Denaturing gradient gel electrophoresis (DGGE) analysis was used to evaluate the major microbial components of the laboratory biofilms. Cyanobacteria, green microalgae, bacteria and fungi were identified by DNA-based molecular analysis targeting the 16S and 18S ribosomal RNA genes. The natural green biofilm was mainly composed by the Chlorophyta Chlorella, Stichococcus, and Trebouxia, and by Cyanobacteria belonging to the genera Leptolyngbya and Pleurocapsa. A number of bacteria belonging to Alphaproteobacteria, Bacteroidetes and Verrucomicrobia were identified, as well as fungi from the Ascomycota. The laboratory colonization experiment on stone probes showed a colonization pattern similar to that occurring on stone monuments. The methodology described in this paper allowed to reproduce a colonization equivalent to the natural biodeteriorating process.

  7. Degradation of Artemisinin-Based Combination Therapies under Tropical Conditions

    Science.gov (United States)

    Hall, Zoe; Allan, Elizabeth Louise; van Schalkwyk, Donelly Andrew; van Wyk, Albert; Kaur, Harparkash

    2016-01-01

    Poor quality antimalarials, including falsified, substandard, and degraded drugs, are a serious health concern in malaria-endemic countries. Guidelines are lacking on how to distinguish between substandard and degraded drugs. “Forced degradation” in an oven was carried out on three common artemisinin-based combination therapy (ACT) brands to detect products of degradation using liquid chromatography mass spectrometry and help facilitate classification of degraded drugs. “Natural aging” of 2,880 tablets each of ACTs artemether/lumefantrine and artesunate/amodiaquine was undertaken to evaluate their long-term stability in tropical climates. Samples were aged in the presence and absence of light on-site in Ghana and in a stability chamber (London), removed at regular intervals, and analyzed to determine loss of the active pharmaceutical ingredients (APIs) over time and detect products of degradation. Loss of APIs in naturally aged tablets (both in Ghana and the pharmaceutical stability chamber) was 0–7% over 3 years (∼12 months beyond expiry) with low levels of degradation products detected. Using this developed methodology, it was found that a quarter of ACTs purchased in Enugu, Nigeria (concurrent study), that would have been classified as substandard, were in fact degraded. Presence of degradation products together with evidence of insufficient APIs can be used to classify drugs as degraded. PMID:26951346

  8. Condition Based Maintenance of Space Exploration Vehicles Using Structural Health Monitoring Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Acellent Technologies proposes to develop an autonomous and automated diagnostic system for condition based maintenance (CBM) of safety critical structures for space...

  9. Orthodontic brackets in high field MR imaging: experimental evaluation of magnetic field interactions at 3.0 tesla; Kieferorthopaedische Brackets in der Hochfeld-Magnetresonanz-Tomographie: Experimentelle Beurteilung magnetischer Anziehungs- und Rotationskraefte bei 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Kemper, J.; Adam, G. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Eppendorf, Hamburg (Germany); Klocke, A.; Kahl-Nieke, B. [Poliklinik fuer Kieferorthopaedie, Universitaetsklinikum Eppendorf, Hamburg (Germany)

    2005-12-15

    Purpose: To evaluate static magnetic field interactions for 32 commonly used orthodontic brackets in a 3.0 T magnetic resonance imaging (MRI) system. Materials and methods: 32 orthodontic brackets consisting of a steel alloy (n=27), a cobalt-chromium alloy (n=2), ceramic (n=1), ceramic with a steel slot (n=1), and titanium (n=1) from 13 different manufacturers were tested for magnetic field interactions in a static magnetic field at 3.0 T (Gyroscan Intera 3.0 T, Philips Medical Systems, Best, Netherlands). The magnetic deflection force F{sub Z} [mN] was evaluated by determining the deflection angle {beta}[ ] using the established deflection angle test according to the ASTM guidelines. The magnetic-field-induced rotational force F{sub rot} or torque was qualitatively determined using a 5-point grading scale (0: no torque; +4: very strong torque). Results: In 18 of the 32 brackets, the deflection angle {beta} was found to be > 45 and the translational force exceeded the gravitational force F{sub G} on the particular bracket (F{sub Z}: 1.2-45.7 mN). The translational force F{sub Z} was found to be up to 68.5 times greater than the gravitational force F{sub G} (F{sub Z}/F{sub G}: 1.4-68.5). The rotational force F{sub rot} was correspondingly high (+3/+4) for those brackets. For the remaining 14 objects, the deflection angles were < 45 and the torque measurements ranged from 0 to +2. The static magnetic field did not affect the titanium bracket and the ceramic bracket. No measurable translational and rotational forces were found. (orig.)

  10. Comparative evaluation of the shear bond strength of metal brackets bonded to porcelain using different porcelain surface treatments

    Directory of Open Access Journals (Sweden)

    Eslami Amirabadi GH

    2011-02-01

    Full Text Available "nBackground and Aims: The aim of this in vitro study was to compare shear bond strength of metal brackets bonded to dental porcelain on the basis of presence or absence of silane, type of acid [hydrofluoric acid (HF or phosphoric acid (H3PO4] and roughness of porcelain surface (glazed or deglazed within mouth-like environment."nMaterials and Methods: Eighty glazed ceramic disks were randomly divided into 8 groups of 10 disks: group 1 [HF+silane], group 2 [deglazed+HF+silane], group 3 [HF], group 4 [deglazed+HF], group 5 [H3PO4+silane], group 6 [deglazed+H3PO4+silane], group 7 [H3PO4], group 8 [deglazed+H3PO4]. Then the brackets were bonded and thermocycled. After that, shear bond strength test was done using the Zwick device and the type of bond failure was determined under stereomicroscope at 4X magnification. 3-way ANOVA and Kruskal-Wallis were used for statistical analyses."nResults: The shear bond strength for the test groups were as follows: group (1:13.05±7.7 MPa , group (2:25.16±10.66 MPa, group (3:6.7±5.86 MPa, group (4:15.39±8.97 MPa, group (5:12.76±7.91 MPa, group (6:13.57±7.85 MPa, group (7:0.54±0.67 MPa, group (8: 9.34±6.52 MPa. The type of bond failure in all groups was adhesive failure except for group 2. No significant difference in the interaction between (glazed or deglazed, (presence or absence of silane, and type of acid was found (P>0.05."nConclusion: Under the conditions of this study, the best clinical method was the use of 37% phosphoric acid and silane that resulted in the optimal clinical strength and adhesive bond failure.

  11. Some Characterization Results based on Conditional Expectation of function of Dual Generalized Order Statistics

    Directory of Open Access Journals (Sweden)

    Md Izhar Khan

    2012-11-01

    Full Text Available  Two families of probability distributions are characterized through the conditional expectations of dual generalized order statistics ( , conditioned on a non-adjacent dual generalized order statistics. Also a result based on the unconditional expectation and a conditional expectation of  is used to characterize family of distributions. Further, some of its deductions are also discussed.

  12. Differential Effects of a Food-Based Conditioned Inhibitor on Food- or Cocaine-Seeking Behavior

    Science.gov (United States)

    Lombas, Andres S.; Kearns, David N.; Weiss, Stanley J.

    2008-01-01

    The present experiment compared the effects of a food-based conditioned inhibitor on food seeking vs. cocaine seeking behavior. In two groups of rats, the A+/AB- Pavlovian conditioned inhibition procedure was used to create a conditioned inhibitor for food. Then, for one group of rats (Food-Food Group), a click stimulus was established as an…

  13. Effects of fluoride release from orthodontic bonding materials on nanomechanical properties of the enamel around orthodontic brackets

    Directory of Open Access Journals (Sweden)

    Seyed Hamid Raji

    2014-01-01

    Full Text Available Background: The aim of the present study is to evaluate the effects of a fluoride-releasing composite resin bonding material on reducing enamel demineralization underneath and around orthodontic brackets and compare that with a conventional adhesive system. Materials and Methods: Buccal surfaces of 10 intact extracted premolar teeth were divided into two parts with nail varnish and stainless steel brackets were randomly bonded by two resin composite systems: (Transbond XT and (Transbond XT plus Color Change (3M, Unitek, Monrovia, CA, USA on two sides of the teeth and then samples were placed in a demineralization solution. It is claimed that the second system has the ability of fluoride release. Elastic modulus and hardness of enamel were measured with nanoindentation test in 6 depths in 1-36 μm from the enamel surface and in 7 regions: Control (intact enamel surface, underneath the brackets and also 50 and 100 μm from the brackets edge. These nanomechanical features were evaluated in different regions and depths using analysis of variance and paired t-test (P < 0.05. Results: Considerable difference can be seen in different depths and regions in terms of hardness and elastic modulus. The region under the bracket with fluoridated adhesive shows similar results with intact enamel, whereas these parameters in fluoride less side show a significant reduction (P < 0.05. Conclusion: Results show that use of resin composite bonding system with the ability of fluoride release for bracket bonding, may reduce demineralization of enamel around brackets during orthodontic treatment.

  14. Study on bonding strength of nitrogen-doped TiO2-xNx films to orthodontic brackets%掺氮TiO2-xNx薄膜托槽粘接强度的研究

    Institute of Scientific and Technical Information of China (English)

    王璞; 曹宝成; 王婧; 曹帅; 高静; 王育华

    2012-01-01

    目的 研究掺氮TiO2-xNx薄膜托槽的制备过程对粘接强度的影响.方法 应用磁控溅射法在普通金属托槽表面制备TiO2-xNx薄膜得到掺氮TiO2-xNx薄膜托槽,将掺氮TiO2-xNx薄膜托槽通入氮气后在450℃条件下退火处理2h得到退火后掺氮TiO2-xNx薄膜托槽.通过X射线衍射观察普通金属托槽及退火前、退火后掺氮TiO2-xNx薄膜托槽表面结构,通过扫描电镜(SEM)观察3种托槽网底形貌.将60颗因正畸需要已拔除的健康前磨牙按照3种托槽和2种储存条件(室温蒸馏水、冷热循环)随机分为6组,每组10颗,使用京津釉质粘合剂按要求粘接,用电子万能材料试验机测试并记录所有托槽的剪切强度,使用SPSS 17.0统计软件处理数据,并对实验结果进行单因素方差分析.结果 掺氮TiO2-xNx薄膜托槽表面为均一的锐钛矿相结构,晶粒粒径为30 nm.3种托槽的底板网格清晰,排列整齐,无明显不同.冷热循环条件下的3种托槽粘接强度均低于室温蒸馏水保存下的托槽粘接强度(P<0.01),同一处理条件下3种托槽的粘接强度差异无统计学意义(P>0.05).结论 掺氮TiO2-xNx薄膜托槽的粘接强度没有受到制备过程的影响,能够满足临床正畸治疗需要.%Objective To evaluate the effect of preparation process on the bonding strength of the nitrogen-doped TiO2-xNx films on brackets. Methods Radio frequency magnetron sputtering was used to prepare nitrogen-doped TiO2-xNx films on the surface of stainless steel brackets. Post annealing was performed on TiC>2-x Nx films at 450'C in nitrogen atmosphere for 2 h. The structures and surface morphologies of 3 types brackets, ordinary stainless steel brackets, nitrogen-doped TiO2-xNx films on brackets before annealing and the brackets after annealing, were evaluated by X-ray diffraction. The base plate of brackets was observed by scanning electron microscopy (SEM). The three types of brackets were also divided into 2 groups

  15. Symbolic algorithms for the computation of Moshinsky brackets and nuclear matrix elements

    Science.gov (United States)

    Ursescu, D.; Tomaselli, M.; Kuehl, T.; Fritzsche, S.

    2005-12-01

    To facilitate the use of the extended nuclear shell model (NSM), a FERMI module for calculating some of its basic quantities in the framework of MAPLE is provided. The Moshinsky brackets, the matrix elements for several central and non-central interactions between nuclear two-particle states as well as their expansion in terms of Talmi integrals are easily given within a symbolic formulation. All of these quantities are available for interactive work. Program summaryTitle of program:Fermi Catalogue identifier:ADVO Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADVO Program obtainable from: CPC Program Library, Queen's University of Belfast, N. Ireland Licensing provisions:None Computer for which the program is designed and others on which is has been tested:All computers with a licence for the computer algebra package MAPLE [Maple is a registered trademark of Waterloo Maple Inc., produced by MapleSoft division of Waterloo Maple Inc.] Instalations:GSI-Darmstadt; University of Kassel (Germany) Operating systems or monitors under which the program has beentested: WindowsXP, Linux 2.4 Programming language used:MAPLE 8 and 9.5 from MapleSoft division of Waterloo Maple Inc. Memory required to execute with typical data:30 MB No. of lines in distributed program including test data etc.:5742 No. of bytes in distributed program including test data etc.:288 939 Distribution program:tar.gz Nature of the physical problem:In order to perform calculations within the nuclear shell model (NSM), a quick and reliable access to the nuclear matrix elements is required. These matrix elements, which arise from various types of forces among the nucleons, can be calculated using Moshinsky's transformation brackets between relative and center-of-mass coordinates [T.A. Brody, M. Moshinsky, Tables of Transformation Brackets, Monografias del Instituto de Fisica, Universidad Nacional Autonoma de Mexico, 1960] and by the proper use of the nuclear states in different coupling notations

  16. The influence of practical factors on the benefits of condition-based maintenance over time-based maintenance

    NARCIS (Netherlands)

    de Jonge, Bram; Teunter, Ruud; Tinga, Tiedo

    2017-01-01

    Recent developments in condition monitoring technology have led to an ongoing shift from time-based maintenance (TBM) to condition-based maintenance (CBM). Although CBM allows for more effectively planned maintenance actions, its relative performance strongly depends on the behavior of the deteriora

  17. Signal Processing Technique for Combining Numerous MEMS Gyroscopes Based on Dynamic Conditional Correlation

    OpenAIRE

    Jieyu Liu; Qiang Shen; Weiwei Qin

    2015-01-01

    A signal processing technique is presented to improve the angular rate accuracy of Micro-Electro-Mechanical System (MEMS) gyroscope by combining numerous gyroscopes. Based on the conditional correlation between gyroscopes, a dynamic data fusion model is established. Firstly, the gyroscope error model is built through Generalized Autoregressive Conditional Heteroskedasticity (GARCH) process to improve overall performance. Then the conditional covariance obtained through dynamic conditional cor...

  18. Effect of self-etching primer/adhesive and conventional bonding on the shear bond strength in metallic and ceramic brackets

    Science.gov (United States)

    Kimyai, Soodabeh; Hydari, Mahboubeh; Shahrbaf, Shirin; Mirzakouchaki-Boroujeni, Parvin

    2012-01-01

    Introduction: Bracket debonding from the tooth surface is a common problem in fixed orthodontics. The aims of the present study were to assess the bond strength and failure sites in two ways of bonding technique, with metallic and ceramic brackets. Material and Methods: One hundred premolars were assigned to 4 groups of 25 each: Group A, metallic brackets/ conventional procedure; Group B, metallic brackets/Transbond XT; Group C, ceramic brackets/conventional procedure; and Group D, ceramic brackets/Transbond XT. Transbond XT composite paste was used for bracket bonding and cured by conventional light-cure device. Specimens were subjected to thermocycling. One week after bonding shearing force was applied to the bracket-tooth interface. Bonding failure site optically examined using a stereomicroscope under 10 × magnifications and scoring was done using the adhesive remnant index (ARI). Data were subjected to analysis of One-way variance, Tukey post hoc, Chi-square and Spearman’s tests. Results: Mean bond strength (in MPa) were: group A=9.2, group B=8.5, group C=6.2 and group D=5.7. Bond strength differences between groups A and B, and between C and D were not significant, (pceramic ones and the selfetching primer produce fewer bonds than the conventional method (clinically acceptable). A positive correlation found between changes in shearing bond strength and ARI. Key words: Acid etching, adhesive remnant index, orthodontic brackets, self-etching primer, shearing bond strength. PMID:21743430

  19. THE ANALYSIS OF THE INFLUENCE OF THE CHARACTERISTICS OF SUSPENSION BRACKET AND TIRES ON LOADING OF WHEELS OF THE CAR WHEN MOVING ON A MULCH BACKGROUND

    Directory of Open Access Journals (Sweden)

    Oberemok V. A.

    2015-05-01

    Full Text Available The existing settlement modes of loading of wheels of cars are defined for the conditions which are closest to road service conditions and are reflected in the existing standards. However these standards can't be applied to an assessment of functional qualities of systems of cushioning the cars which are operated in the conditions of agricultural production. The small step of roughnesses, change the cushioned characteristics under the influence of operational factors lead to emergence of the off-design modes of the movement. The purpose of the work was the research of loading of wheels of the car when moving on mulch of grains. For the purpose of obtaining characteristics of the roughnesses influencing car wheels we have recorded a smoothed microprofile of the field and got the statistics, rated autocorrelated function, spectral density of influence of a microprofile. For carrying out the researches the known mathematical model of a car road system was accepted. Influence of speed of the movement, normal rigidity of springs and tires, coefficients of damping of a suspension bracket and tires on vertical fluctuations and loading of wheels of forward and back axes of the car is investigated. The executed researches showed that the movement of the car is followed by fluctuations of indicators of loading of running system with obviously expressed periodic components. The change of the coefficient of damping of a passive suspension bracket and tires in possible limits has no essential impact on loading of wheels. Values of normal roughness of springs of forward and back axes of the car, normal rigidity of tires at which dynamic load of wheels of the car is minimum are established

  20. Influence of bleaching and desensitizing gel on bond strength of orthodontic brackets.

    Science.gov (United States)

    Britto, Fernanda Alves Rodrigues; Lucato, Adriana Simoni; Valdrighi, Heloisa Cristina; Vedovello, Sílvia Amélia Scudeler

    2015-01-01

    The objective of this study was to assess, in vitro, the influence of bleaching gel and the use of desensitizing agent over bond strength of ceramic brackets bonded to bovine enamel. One hundred bovine incisors were selected and randomly divided into five groups (n = 20): Group 1, control group (without bleaching); Group 2, bleached with 35% hydrogen peroxide; Group 3, bleached with 35% hydrogen peroxide (three applications, 15 minutes each) and desensitizing agent applied for 10 minutes; Group 4, bleached with 35% hydrogen peroxide for 40 minutes; Group 5, bleached with 35% hydrogen peroxide for 40 minutes with desensitizing agent applied for 10 minutes. Brackets were bonded 7 days after bleaching and submitted to shear bond strength test after 24 hours at a compression rate of 1 mm/minute. After fracture, the adhesive remnant index (ARI) was assessed under stereoscopic at 40 x magnification. Shear strength data (MPa) were submitted to one-way ANOVA and Tukey's test with significance level set at 5%. Group 5 (29.33 MPa) showed significantly higher bond strength than Group 1 (19.19 MPa), Group 2 (20.59 MPa) and Group 4 (23.25 MPa), but with no difference in comparison to Group 3. There was no significant difference among the other groups. The adhesive remnant index showed predominance of score 3, that is, all resin remained adhered to enamel for all groups. Bleaching with 35% hydrogen peroxide with calcium associated with desensitizing agent application produced higher bond strength values of brackets bonded to bovine enamel.

  1. CO2 laser as auxiliary in the debonding of ceramic brackets.

    Science.gov (United States)

    Macri, Rodrigo Teixeira; de Lima, Fabrício Augusto; Bachmann, Luciano; Galo, Rodrigo; Romano, Fábio Lourenço; Borsatto, Maria Cristina; Matsumoto, Mírian Aiko Nakane

    2015-09-01

    This study evaluated the temperature in the bonding composite and in the pulp chamber, the shear bond strength after the irradiation of CO2 lasers, and the Adhesive Remnant Index (ARI) after debonding of ceramic bracket. A hundred and five premolars were used: 30 to evaluate the temperature and 75 to test the resistance to shear and the ARI. To assess the temperature, different irradiation times (3 and 5 s), pulse duration (0.001 and 0.003 s), and output power (5, 8, and 10 W) were tested (total of 12 groups). During all the irradiation, specimens were immersed in thermal bath water at 37 °C. In the test and ARI evaluation, premolars were divided into five groups (n = 15) and were submitted to the following regimens of CO2 laser irradiation: I (5 W, pulse duration = 0.01 s, application time = 3 s), II (5 W, 0.03 s, 3 s), III (8 W, 0.01 s, 3 s), and IV (1 0 W, 0.01 s, 3 s). Group C (control) was not subjected to irradiation. ARI was measured after debonding of the bracket. Following irradiation of the lasers, the pulpal temperature was not higher than 5.5 °C in four of the study groups. Results were submitted to the ANOVA and Duncan's test. CO2 laser irradiation regimen IV was one in which the strength of debonding is 7.33 MPa. Therefore, CO2 laser may aid removal of ceramic brackets; it decreased the bond strength without increasing the excessive temperature excessively.

  2. Fluoride-Releasing Materials to Prevent White Spot Lesions around Orthodontic Brackets: A Systematic Review.

    Science.gov (United States)

    Nascimento, Patrícia Layane de Menezes Macêdo; Fernandes, Micaelle Tenório Guedes; Figueiredo, Fabricio Eneas Diniz de; Faria-E-Silva, André Luis

    2016-01-01

    The relation between orthodontic fixed appliances use and enamel demineralization is well established. Different preventive approaches have been suggested to this problem, but controversy remains about which is the best. The aim of this study was to perform a systematic review of clinical trials that investigated the effectiveness of materials containing fluorides to lute brackets or cover the bonding interface in order to inhibit the development and progression of white spot lesions. The null hypothesis was that fluoride materials do not affect the incidence of white spot lesions around brackets. A MEDLINE search was conducted for randomized clinical trials evaluating the development of white spot lesions in patients using fixed orthodontic appliances, followed by meta-analysis comparing the results for patients for whom dental materials containing fluorides were used (experimental group) to those for whom these materials were not used (control group). The pooled relative risk of developing white spot lesions for the experimental group was 0.42 (95% confidence interval: 0.25 to 0.72); hence, when fluoride-releasing materials are used, the patient has 58% less risk of white spot lesion development. Regarding white spot lesion extent, the pooled mean difference between the experimental and control groups was not statistically significant (-0.12; 95% confidence interval: -0.29 to 0.04). In conclusion, the results of the present systematic review suggest that fluoride-releasing materials can reduce the risk of white spot lesions around brackets. However, when white spot lesions had already occurred, there is no evidence that fluoride-releasing materials reduce the extent of these lesions.

  3. Effectiveness of fluoride sealant in the prevention of carious lesions around orthodontic brackets: an OCT evaluation

    Directory of Open Access Journals (Sweden)

    Matheus Melo Pithon

    2015-12-01

    Full Text Available Abstract Objective: This article aimed to evaluate in vitro the efficiency of Pro Seal fluoride sealant application in the prevention of white spot lesions around orthodontic brackets. Material and Methods: Brackets were bonded to the buccal surface of bovine incisors, and five groups were formed (n = 15 according to the exposure of teeth to oral hygiene substances and the application of enamel sealant: G1 (control, only brushing was performed with 1.450 ppm fluoride; G2 (control brushing associated with the use of mouthwash with 225 ppm fluoride; G3, only Pro Seal sealant application was performed with 1.000 ppm fluoride; G4 Pro Seal associated with brushing; G5 Pro Seal associated with brushing and mouthwash. Experimental groups alternated between pH cycling and the procedures described. All specimens were kept at a temperature of 37 °C throughout the entire experiment. Both brushing and immersion in solutions were performed within a time interval of one minute, followed by washing in deionized water three times a day for 28 days. Afterwards, an evaluation by Optical Coherence Tomography (OCT of the spectral type was performed. In each group, a scanning exam of the white spot lesion area (around the sites where brackets were bonded and depth measurement of carious lesions were performed. Analysis of variance (ANOVA was applied to determine whether there were significant differences among groups. For post hoc analysis, Tukey test was used. Results: There was statistically significant difference between groups 1 and 2 (p = 0.003, 1 and 3 (p = 0.008, 1 and 4 (p = 0.000 and 1 and 5 (p = 0.000. The group in which only brushing was performed (Group 1 showed deeper enamel lesion. Conclusion: Pro Seal sealant alone or combined with brushing and/or brushing and the use of a mouthwash with fluoride was more effective in protecting enamel, in comparison to brushing alone.

  4. Enamel surface evaluation after bracket debonding and different resin removal methods

    Directory of Open Access Journals (Sweden)

    Michele Machado Vidor

    2015-04-01

    Full Text Available OBJECTIVE: To assess enamel surface under scanning electron microscopy (SEM after resin removal and enamel polishing procedures following brackets debonding, as well as compare the time required for these procedures. METHODS: A total of 180 deciduous bovine incisors were used. The enamel surface of each tooth was prepared and brackets were bonded with light cured Transbond XT composite resin. Brackets were removed in a testing machine. The samples were randomized and equally distributed into nine groups according to the resin removal and polishing technique: Group 1, 30-blade tungsten carbide bur in high speed; Group 2, 30-blade tungsten carbide bur in high speed followed by a sequence of 4 Sof-lex polishing discs (3M; Group 3, 30-blade tungsten carbide bur in high speed followed by Enhance tips (Dentsply. All groups were subdivided into (a unpolished; (b polished with aluminum oxide paste; and (c polished with water slurry of fine pumice. Subsequently, the enamel surface was assessed and statistical analysis was carried out. RESULTS: There were statistically significant differences in enamel roughness and removal time among all groups. Groups 3a, 3b and 3c appeared to be the most efficient methods of removing resin with low damages to enamel. Groups 2a, 2b and 2c were the most time consuming procedures, and Group 2a caused more damages to enamel. CONCLUSION: The suggested protocol for resin removal is the 30-blade tungsten carbide bur in high speed followed by Enhance tips and polishing with aluminum oxide paste. This procedure seems to produce less damages and is less time consuming.

  5. Sistemas de brackets de baja fricción en ortodoncia clínica

    OpenAIRE

    Segovia, Wilfredo Daniel

    2011-01-01

    Los sistemas de brackets de baja fricción reducen la fricción en comparación con los convencionales. La fricción se define como la fuerza resistencia entre dos objetos en movimiento que entran en contacto. Junto con la fijación (binding) y la muesca (notching), la fricción es responsable de la resistencia de deslizamiento que se observa en ortodoncia en las etapas de alineado, nivelado y cierre de espacios. Se ha establecido que la a...

  6. Sistemas de brackets de baja fricción en ortodoncia clínica

    OpenAIRE

    2011-01-01

    Los sistemas de brackets de baja fricción reducen la fricción en comparación con los convencionales. La fricción se define como la fuerza resistencia entre dos objetos en movimiento que entran en contacto. Junto con la fijación (binding) y la muesca (notching), la fricción es responsable de la resistencia de deslizamiento que se observa en ortodoncia en las etapas de alineado, nivelado y cierre de espacios. Se ha establecido que la a...

  7. Effect of remineralizing agents on bond strength of orthodontic brackets: an in vitro study.

    Science.gov (United States)

    Ladhe, Kapil A; Sastri, Murlidhar R; Madaan, Jyoti B; Vakil, Ketan K

    2014-04-16

    The purpose of this study is to evaluate the effect of casein phosphopeptide amorphous calcium phosphate (CPP-ACP) and CPP-ACP with fluoride (CPP-ACP-F) on the shear bond strength (SBS) of orthodontic brackets bonded with two different adhesive systems. One hundred twenty-six human premolar teeth were selected. One hundred twenty teeth were used for SBS testing, and six teeth were used for scanning electron microscope (SEM) examination. One hundred twenty premolars were divided into mainly three groups: CPP-ACP (group A), CPP-ACP-F (group B), and control group (group C). Each group was sub-divided into two groups according to the bonding adhesive, light cure (groups A1, B1, and C1) and chemical cure (groups A2, B2, and C2). The teeth were pre-treated with the group-specified preventive agent 1 h/day for five consecutive days. Standard edgewise brackets were bonded with the respective adhesives. SBS evaluation was done with the universal testing machine. After debonding, all the teeth were scored for adhesive remaining on the buccal surface, in accordance to adhesive remnant index, under a stereomicroscope. The acid-etched enamel surfaces were observed under SEM after treatment with CPP-ACP, CPP-ACP-F, and artificial saliva. In light-cure adhesive group, CPP-ACP-F (B1) showed superior results compared to the control group (C1), whereas the CPP-ACP group (A1) showed lower mean SBS than the control group (C1). Both these differences were not statistically significant (p > 0.05). In chemical-cure adhesive group, control group C2 showed significantly superior results (p types (p  0.01). The SBS of the orthodontic brackets was non-significantly affected when the brackets were cured with light-cure bonding system and treated with either CPP-ACP or CPP-ACP-F, whereas with chemical-cure adhesive, decreased bond strength was seen, which was within the clinically acceptable limits.

  8. Design of the Injection Mold for Plastic Pipe Bracket%塑管支架注射模设计

    Institute of Scientific and Technical Information of China (English)

    陈焕东; 张兰英

    2012-01-01

    通过对塑料支架塑件结构的分析,介绍了该塑件注射模的成型工艺过程,提出了模具采用塑件侧面作为分型面的方案,使模具在采用斜导柱侧向抽芯机构脱模时,其结构简单实用,易于加工调试,解决了注射成型后塑件的脱模的问题。经大批量的生产检验,该模具结构合理,生产效率高,塑件质量好。%Based on the analysis of structure of product of plastic bracket, introduced the injection mold of the molding process, put forward by product as mold side parting surface scheme, the die in the inclined guide pillar side pulling-core mechanism of stripping, the structure is simple and practical, easy processing and debugging, solved after injection molding product release problemo The products in large quantities of production test, the die structure is reasonable, high production efficiency, good product quality.

  9. Design of progressive die for spacer positioning bracket%定位支架级进模设计

    Institute of Scientific and Technical Information of China (English)

    李昌雪; 李捷

    2011-01-01

    对定位支架的成形工艺进行分析,制定了合理的冲压工艺,设计了生产定位支架的精密级进模,介绍了模具结构特点和零件端部圆弧与Z形弯曲结构,合理布置浮顶镶件控制成形.实践证明:模具结构合理、可靠,生产的零件合格,对类似零件的成形有一定的参考价值.%Based on analysis on the forming technique of a spacer bracket, a stamping process was determined and a precision progressive die was developed. The die structure features, the arc at the part end and the Z-shaped bend structure were presented. The die is characteristic with application of floating ejector pins in control of forming.

  10. A clinical and radiographic study to evaluate the rate of retraction of maxillary canine using nickel-titanium closed coil spring with two different bracket systems

    Directory of Open Access Journals (Sweden)

    P Adarsh Reddy

    2014-01-01

    Full Text Available Objectives: This study compares the efficiency of self-ligating brackets with the conventional preadjusted edgewise (PEA brackets during maxillary canine retraction using nickel-titanium closed coil springs. Materials and Methods: The sample comprised of 20 healthy patients (10 males and 10 females, within age groups 16-26 years (mean, 20 years having Class I malocclusion with bimaxillary protrusion. All patients underwent bilateral extraction of the maxillary first bicuspids and retraction of the maxillary canines with fixed self-ligating brackets (3M Smart clip and PEA appliance (3M Gemini. The initial records included standard intra- and extra-oral photographs, study models, lateral cephalograms, and panoramic radiographs. Results: The mean distal movement of canines in self-ligating brackets was 0.89 mm/mo with standard deviation of 0.255 and in preadjusted edgewise brackets, the mean distal movement of canines was 0.87 mm/mo with standard deviation of 0.214. The mean tipping of canine in self-ligating brackets was 7.45 ± 1.050(0 and in PEA brackets it was 7.70° ± 1.21°. The mean rotation of canine in self-ligating brackets was 7.65° ± 3.47° and in preadjusted edgewise appliance it was 12.30° ± 3.08°. Conclusion: The rates of distal movement of the maxillary canines were similar with both conventional and self-ligating brackets. Rotation of the maxillary canines during retraction was minimized with self-ligating brackets in comparison to conventional bracket systems.

  11. Performance Analysis of Doubly Fed Induction Generator Based Wind turbine under Faulty and RLC Load Conditions

    Directory of Open Access Journals (Sweden)

    Rekha Parashar

    2015-02-01

    Full Text Available This paper presents the performance of Doubly Fed Induction Generator based wind turbine system during different types of grid fault. The doubly fed induction generator (DFIG based wind turbine (WT system provides better power delivery towards the demand. The design and response of the DFIG based wind turbine system during different fault conditions, various load conditions and integrated system consisting of DFIG based WT system have been verified using MATLAB/ Simulink. The simulation results are shown with the model of DFIG based wind energy generation system.

  12. ICBC Version 3. 1: TMI-2 (Three Mile Island) Initial and Boundary Conditions data base

    Energy Technology Data Exchange (ETDEWEB)

    Brower, R W; Fackrell, L J; Golden, D W; Harris, M L; Olaveson, C L

    1988-01-01

    The TMI-2 initial and boundary conditions data base is a micro computer data base which provides the required initial and boundary conditions to simulate the TMI-2 accident. Additionally, other time series plant measurements related to the accident are included in the data base. Major features of the data base are the ability to plot, manipulate and list data as well as to enter user supplied data (e.g. results of simulations). The user guide provides the instructions for installation and operation of the data base. 10 refs., 21 figs.

  13. A Web-based Condition Monitoring and Diagnostic System of Rolling Mill

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    A web-based condition monitoring and fault diagnosis system (CMAFDS) for the F2 finishing mill of the 2050 Hot Strip Mill was developed at a steel works. The features of the condition monitoring and fault diagnosis system based on the Web are analyzed in this paper. This paper also describes the main frame of the hardware and the software in the system and emphatically points out the function of the database management system(DBMS) based on the Web. It is proved that the web-based CMAFDS is practical in technology and much superior to the CMAFDS based on other network technology in functions.

  14. Research on Network-based Integrated Condition Monitoring Unit for Rotating Machinery

    Institute of Scientific and Technical Information of China (English)

    XI Xiao-peng; ZHANG Wen-rui; XI Shuan-min; JING Min-qing; YU Lie

    2004-01-01

    In this paper, a network-based monitoring unit for condition monitoring and fault diagnosis of rotating machinery is designed and implemented. With the technology of DSP( Digital signal processing), TCP/IP, and simultaneous acquisition, a mechanism of multi-process and inter-process communication, the integrating problem of signal acquisition, the data dynamic management and network-based configuration in the embedded condition monitoring system is solved. It offers the input function of monitoring information for network-based condition monitoring and a fault diagnosis system.

  15. Bone marrow transplantation for Fanconi anemia using fludarabine-based conditioning.

    Science.gov (United States)

    Stepensky, Polina; Shapira, Michael Y; Balashov, Dmitry; Trakhtman, Pavel; Skorobogatova, Elena; Rheingold, Lyudmila; Brooks, Rebecca; Revel-Vilk, Shoshana; Weintraub, Michael; Stein, Jerry; Maschan, Alexey; Or, Reuven; Resnick, Igor B

    2011-09-01

    In the mid-1990s, we introduced a fludarabine (Flu)-based conditioning regimen for hematopoietic stem cell transplantation (HSCT) in patients with Fanconi anemia (FA).The aim of this study is to compare Flu-based conditioning to alternative regimens in patients with FA. Forty-one patients with FA (aged 0.5-31, median, 10.3 years) who underwent allogeneic HSCT were included in this retrospective study. Hospital records were reviewed for conditioning regimens, engraftment data, and toxicity. The median (range) follow-up was 32 (0.5-149) months. Flu-based conditioning regimens were used in 24 patients: 17 patients were treated with alternative conditioning regimens including a radiation-based regimen/cyclophosphamide and busulfan regimen. The disease-free survival (DFS) after Flu-based regimens is 83% (20/24) versus 35% (6/17) for the alternative regimens (P = .002). Toxicity was significantly lower in patients who received Flu-based conditioning (modified Bearman toxicity score [P = .001]). Seven patients received transplants from matched unrelated donors without irradiation (5 of whom are currently alive and well). All patients who survived are disease free and in good clinical condition. We conclude that a combination of fludarabine with antithymocyte globulin (ATG) and low-dose cyclophosphamide (Cy) and/or busulfan (Bu) is safe, demonstrates low rejection rates, and is well tolerated by FA patients. Copyright © 2011 American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  16. Modeling of engine parameters for condition-based maintenance of the MTU series 2000 diesel engine

    OpenAIRE

    Yue, Siew Peng

    2016-01-01

    Approved for public release; distribution is unlimited Condition-based maintenance (CBM) entails performing maintenance only when needed to save on resources and cost. Formulating a model that reflects the behavior of the marine diesel engine in its normal operating conditions would aid in making predictions of the behavior of a condition monitoring parameter. Modeling for CBM is a data-dependent process. Data acquisition, processing, and analysis are required for modeling the behavior of ...

  17. Heterogeneous Web Data Extraction Algorithm Based On Modified Hidden Conditional Random Fields

    OpenAIRE

    Cui Cheng

    2014-01-01

    As it is of great importance to extract useful information from heterogeneous Web data, in this paper, we propose a novel heterogeneous Web data extraction algorithm using a modified hidden conditional random fields model. Considering the traditional linear chain based conditional random fields can not effectively solve the problem of complex and heterogeneous Web data extraction, we modify the standard hidden conditional random fields in three aspects, which are 1) Using the hidden Markov mo...

  18. Assessment of pain experience in adults and children after bracket bonding and initial archwire insertion

    Directory of Open Access Journals (Sweden)

    Marcio José da Silva Campos

    2013-10-01

    Full Text Available INTRODUCTION: Ninety five percent of orthodontic patients routinely report pain, due to alterations in the periodontal ligament and surrounding soft tissues, with intensity and prevalence varying according to age. OBJECTIVE: This study aimed to assess toothache and buccal mucosal pain in adults and children during two initial phases of the orthodontic treatment. METHODS: The intensity of toothache and buccal mucosal pain reported by 20 patients, 10 children (11-13 years and 10 adults (18-37 years was recorded with the aid of a Visual Analog Scale (VAS, during 14 days - 7 days with bonded brackets only and 7 days with the initial archwire inserted. RESULTS: There was no significant difference in pain intensity among adults and children. After bracket bonding, 50% of the children and 70% of the adults reported pain. 70% of both groups reported pain after initial archwire insertion. While adults reported constant, low intensity, buccal mucosal pain, the children showed great variation of pain intensity, but with a trend towards decreasing pain during the assessment period. After initial archwire insertion the peaks of toothache intensity and prevalence occurred 24 hours in children and 48 hours in adults. CONCLUSIONS: In general, children reported pain less frequently than adults did, though with greater intensity.

  19. Effects of surface treatment of provisional crowns on the shear bond strength of brackets

    Directory of Open Access Journals (Sweden)

    Josiane Xavier de Almeida

    2013-08-01

    Full Text Available OBJECTIVE: To assess the adhesive resistance of metallic brackets bonded to temporary crowns made of acrylic resin after different surface treatments. METHODS: 180 specimens were made of Duralay and randomly divided into 6 groups (n = 30 according to surface treatment and bonding material: G1 - surface roughening with Soflex and bonding with Duralay; G2 - roughening with aluminum oxide blasting and bonding with Duralay; G3 - application of monomer and bonding with Duralay; G4 - roughening with Soflex and bonding with Transbond XT; G5 - roughening with aluminum oxide blasting and bonding with Transbond XT and G6: application of monomer and bonding with Transbond. The results were statistically assessed by ANOVA/Games-Howell. RESULTS: The means (MPa were: G1= 18.04, G2= 22.64, G3= 22.4, G4= 9.71, G5= 11.23, G6= 9.67. The Adhesive Remnant Index (ARI ranged between 2 and 3 on G1, G2 and G3 whereas in G4, G5 and G6 it ranged from 0 to 1, showing that only the material affects the pattern of adhesive flaw. CONCLUSION: The surface treatment and the material influenced adhesive resistance of brackets bonded to temporary crowns. Roughening by aluminum blasting increased bond strength when compared to Soflex, in the group bonded with Duralay. The bond strength of Duralay acrylic resin was superior to that of Transbond XT composite resin.

  20. Effect of adhesive remnant removal on enamel topography after bracket debonding

    Directory of Open Access Journals (Sweden)

    Larissa Adrian Meira Cardoso

    2014-12-01

    Full Text Available INTRODUCTION: At orthodontic treatment completion, knowledge about the effects of adhesive remnant removal on enamel is paramount.OBJECTIVE: This study aimed at assessing the effect of different adhesive remnant removal methods on enamel topography (ESI and surface roughness (Ra after bracket debonding and polishing.METHODS: A total of 50 human premolars were selected and divided into five groups according to the method used for adhesive remnant removal: high speed tungsten carbide bur (TCB, Sof-Lex discs (SL, adhesive removing plier (PL, ultrasound (US and Fiberglass burs (FB. Metal brackets were bonded with Transbond XT, stored at 37oC for 24 hours before debonding with adhesive removing plier. Subsequently, removal methods were carried out followed by polishing with pumice paste. Qualitative and quantitative analyses were conducted with pre-bonding, post-debonding and post-polishing analyses. Results were submitted to statistical analysis with F test (ANOVA and Tukey's (Ra as well as with Kruskal-Wallis and Bonferroni tests (ESI (P < 0.05.RESULTS: US Ra and ESI were significantly greater than TCB, SL, PL and FB. Polishing minimized Ra and ESI in the SL and FB groups.CONCLUSION: Adhesive remnant removal with SL and FB associated with polishing are recommended due to causing little damage to the enamel.

  1. In vivo bonding of orthodontic brackets to fluorosed enamel using an adhesion promotor.

    Science.gov (United States)

    Noble, James; Karaiskos, Nicholas E; Wiltshire, William A

    2008-03-01

    To determine the success of bracket retention using an adhesion promoter with and without the additional microabrasion of enamel. Fifty-two teeth with severe dental fluorosis were bonded in vivo using a split-mouth design where the enamel surfaces of 26 teeth were microabraded with 50 microm of aluminum silicate for 5 seconds under rubber dam and high volume suction. Thirty-seven percent phosphoric acid was then applied to the enamel, washed and dried, and followed by placement of Scotchbond Multipurpose Plus Bonding Adhesive. Finally, precoated 3M Unitek Victory brackets were placed and light cured. The remaining teeth were bonded using the same protocol but without microabrasion. After 9 months of intraoral service, only one bond failure occurred in the control group where microabrasion was used. Chi-square analysis revealed P = .31, indicating no statistical significance between the two groups. Bonding orthodontic attachments to fluorosed enamel using an adhesion promoter is a viable clinical procedure that does not require the additional micro-mechanical abrasion step.

  2. A model for determining condition-based maintenance policies for deteriorating multi-component systems

    NARCIS (Netherlands)

    Hontelez, J.A.M.; Wijnmalen, D.J.D.

    1993-01-01

    We discuss a method to determine strategies for preventive maintenance of systems consisting of gradually deteriorating components. A model has been developed to compute not only the range of conditions inducing a repair action, but also inspection moments based on the last known condition value so

  3. The influence of condition-based maintenance on workforce planning and maintenance scheduling

    NARCIS (Netherlands)

    Koochaki, Javid; Bokhorst, Jos A. C.; Wortmann, Hans; Klingenberg, Warse

    2013-01-01

    Condition-based maintenance (CBM) is generally considered an attractive maintenance policy for a single component: it uses the operating condition of the component to predict a failure event and therefore tries to avoid any unplanned downtime and unnecessary maintenance activities. However,

  4. Model Based Sensor System for Temperature Measurement in R744 Air Conditioning Systems

    CERN Document Server

    Reitz, Sven; Schneider, Peter

    2008-01-01

    The goal is the development of a novel principle for the temperature acquisition of refrigerants in CO2 air conditioning systems. The new approach is based on measuring the temperature inside a pressure sensor, which is also needed in the system. On the basis of simulative investigations of different mounting conditions functional relations between measured and medium temperature will be derived.

  5. A More Rational Treatment of the Acid-Base Equilibria Applying the Proton Condition, or the Hydroxyl Condition, in Equilibrium. How the Hydroxyls are Additive in Equilibrium: Dissolutions of Bases, Salts and Mixtures.

    Science.gov (United States)

    Casado-Riobó, Alfonso

    2008-01-01

    The calculus of the acid-base equilibria can be rationalized by applying the proton condition or the hydroxyl condition in every case, on solutions of strong bases, mixtures of bases, mixtures of acids and bases, and different salts. Furthermore, applying the proton condition or the hydroxyl condition in equilibrium, it is clearly pointed out that the hydroxyls in equilibrium are additive in solutions of strong bases as well as in those of weak bases.

  6. MEDICION IN VITRO DE LA FUERZA DE FRICCIÓN EN DUPLAS ARCO-BRACKET CON ANGULACIÓN

    OpenAIRE

    Murillo Mora, Emmanuel

    2012-01-01

    En ortodoncia se utilizan técnicas que buscan un máximo control sobre el movimiento de los dientes. Uno de los múltiples factores a considerar en la selección del material, es optar uno que genere menor fuerza friccional.(23). La reducción de la fricción es una de las metas para la nueva generación de bracket. Se investigó la fuerza friccional de 3 tipos de bracket de diferentes marcas comerciales siendo uno de autoligado (Smart Clip) y los otros con eslastomero, en este cas...

  7. Report: Discussion on the development of nano Ag/TiO2 coating bracket and its antibacterial property and biocompatibility in orthodontic treatment.

    Science.gov (United States)

    Zhang, Ronghe; Zhang, Weiwei; Bai, Xueyan; Song, Xiaotong; Wang, Chunyan; Gao, Xinxin; Tian, Xubiao; Liu, Fengzhen

    2015-03-01

    This paper aims to explore the antibacterial property of nano Ag/TiO2 coating bracket for the common bacteria in oral cavity, and discuss its biocompatibility. Micro morphology in the surface of nano Ag/TiO2 coating bracket was detected by scanning electron microscope (SEM), and surface roughness of ordinary mental bracket, nano TiO2 coating bracket and nano Ag/TiO2 coating bracket were measured. First, antibacterial property of nano Ag/TiO2 coating bracket on the common bacteria in oral cavity was studied by sticking membrane method. Secondly, bonding strength of nano TiO2 coating and nano Ag/TiO2 coating bracket in groups were detected by scratching test. The result showed that, the synthetic nano Ag/TiO2 coating was nanogranular films with rigorous organizational structure, presenting as smooth and clean surface, and antibacterial rate of nano Ag/TiO2 coating for the common bacteria in oral cavity for 20 min was more than 79% in the dark. All the findings suggested that, nano Ag/TiO2 coating bracket not only has antibacterial effect but also has good biocompatibility, therefore, it can satisfy the clinical request of orthodontic treatment.

  8. Towards Understanding KOH Conditioning of Amidoxime-based Polymer Adsorbents for Sequestering Uranium from Seawater

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Horng-Bin; Kuo, Li-Jung; Wood, Jordana R.; Strivens, Jonathan E.; Gill, Gary A.; Janke, C.; Wai, Chien M.

    2015-11-16

    Conditioning of polymer fiber adsorbents grafted with amidoxime and carboxylic acid groups is necessary to make the materials hydrophilic for sequestering uranium from seawater. Spectroscopic techniques were employed to study the effectiveness of the traditional KOH conditioning method (2.5% KOH at 80 oC) on recently developed high-surface-area amidoxime-based polymer fiber adsorbents developed at Oak Ridge National Laboratory. FTIR spectra reveal that the KOH conditioning process removes the proton from the carboxylic acids and also converts the amidoxime groups to carboxylate groups in the adsorbent. With prolonged KOH treatment (>1 hr) at 80 oC, physical damage to the adsorbent material occurs which can lead to a significant reduction in the adsorbent’s uranium adsorption capability in real seawater during extended exposure times (>21 days). The physical damage to the adsorbent can be minimized by lowering KOH conditioning temperature. For the high-surface-area amidoxime-based adsorbents, 20 min of conditioning in 2.5% KOH at 80 oC or 1 hr of conditioning in 2.5% KOH at 60 oC appears sufficient to achieve de-protonation of the carboxylic acid with minimal harmful effects to the adsorbent material. The use of NaOH instead of KOH can also reduce the cost of the base treatment process required for conditioning the amidoxime-based sorbents with minimal loss of adsorption capacity (≤ 7%).

  9. 氟牙症患者对托槽粘接效果影响的临床研究初探%Clinical studies the affect of bracket bonded on dental fluorosis patient

    Institute of Scientific and Technical Information of China (English)

    姜国有; 王晓红

    2010-01-01

    目的 探讨影响氟斑牙患者对托槽粘接效果.方法 选取氟斑牙为轻、中、重患者30例,分成A、B、C 3组,年龄在14~20岁的患者,观察托槽粘接效果及时间.结果 轻度氟斑牙A组中轻扫牙面组托槽脱落率明显小于牙面未磨除组;中度氟斑牙B组釉质磨除0.1 mm组托槽脱落率明显小于牙面轻磨除组;重度氟斑牙C组釉质磨除量在0.15 mm以上组托槽脱落率明显小于牙面磨除0.1 mm组.结论 氟斑牙表层釉质的磨除能改变了釉质裘面的物理性状,可提高了粘接效果.%Objective To exploring the effective of patient with the fluorosis to the bracket bonded.Methods Selected 30 cases of patient, age range from 14ys to 20ys old with the dental fluorosis. They were divided into three groups as of A,B,C based on the degrees of mild,sever,and very sever. Observe the time and effect of bracket bonded. Results In mild fluorosis patient ( A group) , the bracket off rate was less in gently grinding dental surface than in non-grinding dental surface patient. In group B, bracket off rate enamel surface grinding 0. 1 mm group was smaller than gently grinding dental surface group; In group C, grinding dental surface in > 0. 15 mm were better than grinding dental surface in 0. 1 mm patient in bracket off rate. Conclusion Grinding the enamel surface of dental fluorosis could be in changing the physical properties of the enamel surface, and enhance the adhesive effect.

  10. Biodegradação de braquetes ortodônticos: avaliação da liberação iônica in vitro Biodegradation of orthodontic brackets: in vitro ion release

    Directory of Open Access Journals (Sweden)

    Gabriel Schmidt Dolci

    2008-06-01

    . CONCLUSION: It was concluded that, under the present study conditions, the brackets from group A presented a higher biodegradation than group’s B brackets, what could be associated to composition and manufacturing process of these brackets.

  11. Planetary gearbox condition monitoring of ship-based satellite communication antennas using ensemble multiwavelet analysis method

    Science.gov (United States)

    Chen, Jinglong; Zhang, Chunlin; Zhang, Xiaoyan; Zi, Yanyang; He, Shuilong; Yang, Zhe

    2015-03-01

    Satellite communication antennas are key devices of a measurement ship to support voice, data, fax and video integration services. Condition monitoring of mechanical equipment from the vibration measurement data is significant for guaranteeing safe operation and avoiding the unscheduled breakdown. So, condition monitoring system for ship-based satellite communication antennas is designed and developed. Planetary gearboxes play an important role in the transmission train of satellite communication antenna. However, condition monitoring of planetary gearbox still faces challenges due to complexity and weak condition feature. This paper provides a possibility for planetary gearbox condition monitoring by proposing ensemble a multiwavelet analysis method. Benefit from the property on multi-resolution analysis and the multiple wavelet basis functions, multiwavelet has the advantage over characterizing the non-stationary signal. In order to realize the accurate detection of the condition feature and multi-resolution analysis in the whole frequency band, adaptive multiwavelet basis function is constructed via increasing multiplicity and then vibration signal is processed by the ensemble multiwavelet transform. Finally, normalized ensemble multiwavelet transform information entropy is computed to describe the condition of planetary gearbox. The effectiveness of proposed method is first validated through condition monitoring of experimental planetary gearbox. Then this method is used for planetary gearbox condition monitoring of ship-based satellite communication antennas and the results support its feasibility.

  12. Sensor Technology Baseline Study for Enabling Condition Based Maintenance Plus in Army Ground Vehicles

    Science.gov (United States)

    2012-03-01

    and mechanisms are identified. Based on this analysis, baselines sensor technologies are determined to prognosticate these types failure causes early...Current/voltage sensor measured at sensor terminals; Fluid level sensor Excessive slippage and clutch chatter Internal transmission failure ... TYPE Final 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Sensor Technology Baseline Study for Enabling Condition Based Maintenance Plus in

  13. SHEAR BOND STRENGTH OF BRACKETS BONDED TO PORCELAIN SURFACE: IN VITRO STUDY

    Directory of Open Access Journals (Sweden)

    Fidan Alakuş Sabuncuoğlu

    2016-01-01

    Full Text Available Purpose: To compare the effects of different porcelain surface treatment methods on the shear bond strength (SBS and fracture mode of orthodontic brackets. Materials and Methods: Seventy feldspathic porcelain disk samples mounted in acrylic resin blocks were divided into seven groups (n=10 according to type of surface treatment: I, Diamond bur; II, Orthosphoric acid (OPA; III, hydrofluoric acid (HFA; IV, sandblasted with aluminum oxide (SB; V, SB+HFA; VI, Neodymium:yttrium-aluminum-garnet (Nd:YAG laser; VII, Erbium:yttrium-aluminum-garnet (Er:YAG laser. Brackets were affixed to treated all-porcelain surfaces with a silane bonding agent and adhesive resin and subjected to SBS testing. Specimens were evaluated according to the adhesive remnant index (ARI, and failure modes were assessed quantitatively under a stereomicroscope and morphologically under a scanning electron microscope (SEM. Statistical analysis was performed using one-way analysis of variance and the post-hoc Tukey test, with the significance level set at 0.05. Results: The highest SBS values were observed for Group V, with no significant difference between Groups V and III. SBS values for Group I were significantly lower than those of all other groups tested. The porcelain/resin interface was the most common site of failure in Group V (40% and Group III (30%, whereas other groups showed various types of bond failure, with no specific location pre-dominating, but with some of the adhesive left on the porcelain surfaces (ARI scores 2 or 3 in most cases. Conclusion: The current findings indicate that a diamond bur alone is unable to sufficiently etch porcelain surfaces for bracket bonding. Moreover, SB and HFA etching used in combination results in a significantly higher shear-bond strength than HFA or SB alone. Finally, laser etching with either an Nd:YAG or Er:YAG laser was found to be more effective and less time-consuming than both HFA acid and SB for the treatment of deglazed

  14. Preconditioned characteristic boundary conditions based on artificial compressibility method for solution of incompressible flows

    Science.gov (United States)

    Hejranfar, Kazem; Parseh, Kaveh

    2017-09-01

    The preconditioned characteristic boundary conditions based on the artificial compressibility (AC) method are implemented at artificial boundaries for the solution of two- and three-dimensional incompressible viscous flows in the generalized curvilinear coordinates. The compatibility equations and the corresponding characteristic variables (or the Riemann invariants) are mathematically derived and then applied as suitable boundary conditions in a high-order accurate incompressible flow solver. The spatial discretization of the resulting system of equations is carried out by the fourth-order compact finite-difference (FD) scheme. In the preconditioning applied here, the value of AC parameter in the flow field and also at the far-field boundary is automatically calculated based on the local flow conditions to enhance the robustness and performance of the solution algorithm. The code is fully parallelized using the Concurrency Runtime standard and Parallel Patterns Library (PPL) and its performance on a multi-core CPU is analyzed. The incompressible viscous flows around a 2-D circular cylinder, a 2-D NACA0012 airfoil and also a 3-D wavy cylinder are simulated and the accuracy and performance of the preconditioned characteristic boundary conditions applied at the far-field boundaries are evaluated in comparison to the simplified boundary conditions and the non-preconditioned characteristic boundary conditions. It is indicated that the preconditioned characteristic boundary conditions considerably improve the convergence rate of the solution of incompressible flows compared to the other boundary conditions and the computational costs are significantly decreased.

  15. Bond of acrylic teeth to different denture base resins after various surface-conditioning methods.

    Science.gov (United States)

    Lang, Reinhold; Kolbeck, Carola; Bergmann, Rainer; Handel, Gerhard; Rosentritt, Martin

    2012-02-01

    The study examined the bond between different denture base resins and highly cross-linked acrylic denture teeth with different base surface-conditioning methods. One hundred fifty highly cross-linked resin denture teeth (SR-Antaris, No. 11, Ivoclar-Vivadent, FL) were divided into five groups with different surface-conditioning methods of the base surfaces of the teeth (C = control, no surface conditioning, MM = application of methyl methacrylate monomer, SB = sand blasting, SBB = sand blasting + bonding agent, TSS = tribochemical silica coating + silanization). Teeth were bonded to either a cold-cured denture base resin (ProBase Cold, Ivoclar-Vivadent, FL) or heat-cured denture base resins (SR Ivocap Plus, Ivoclar-Vivadent, FL and Lucitone 199, Dentsply, USA). After 24 h of storage in distilled water, compressive load was applied at 90° on the palatal surface of each tooth until fracture. Median failure load ranged between 103 and 257 N for Probase Cold groups, 91 to 261 N for Lucitone 199, and 149 to 320 N for SR Ivocap Plus. For Probase Cold, significant highest failure loads resulted when teeth were treated with SB, SBB, or TSS. For Lucitone 199, significant highest failure loads has been found with MM and TSS treatment. For SR Ivocap Plus, highest failure loads resulted using SBB and TSS. Conditioning of the base surfaces of the teeth prior to denture base processing is highly recommended. Tooth bond is significantly affected by the surface-conditioning method and applied denture base resin. Tribochemical silica coating + silanization method can be recommended for pre-treatment of teeth applying either heat-cured or cold-cured denture base resin.

  16. Effect of femtosecond laser treatment on the shear bond strength of a metal bracket to prepared porcelain surface.

    Science.gov (United States)

    Akpinar, Yusuf Ziya; Irgin, Celal; Yavuz, Tevfik; Aslan, Muhammed Ali; Kilic, Hamdi Sukur; Usumez, Aslihan

    2015-04-01

    The aim of this study was to investigate the effects of femtosecond laser treatment (Group FS) on the shear bond strength (SBS) of a metal bracket to prepared porcelain surface, and to compare it with other surface treatment techniques [50 μm Al2O3 sandblasting (Group SB), 9.6% hydrofluoric acid gel (Group HF), and neodymium-doped yttrium aluminium garnet (Nd:YAG laser) (Group NY)]. Because of the increasing number of adult patients in current orthodontic practice, achieving sufficient bond strength of composite resin to porcelain restorations without bond failure during the treatment is a challenge for orthodontists. In total, 80 glazed feldspathic porcelain samples were prepared and randomly assigned to four groups of 20. Treated surfaces were treated with a silane agent. Brackets were bonded to porcelain samples. The specimens were stored in distilled water for 24 h and then thermocycled for 500 cycles between 5° and 55°C. The SBS of the brackets was tested with a universal testing machine at a crosshead speed of 1 mm/min, until bonding failure occurred. The data were analyzed statistically using analysis of variance (ANOVA) and Tamhane multiple comparisons tests. The results of ANOVA indicated that the SBS values varied according to the surface treatment method (ptreatment produced high SBS of the processes assessed; therefore, it appears to be an effective method for bonding orthodontic metal brackets to prepared porcelain surfaces.

  17. The effects of two soft drinks on bond strength, bracket microleakage, and adhesive remnant on intact and sealed enamel.

    Science.gov (United States)

    Navarro, Raúl; Vicente, Ascensión; Ortiz, Antonio J; Bravo, Luis A

    2011-02-01

    The purpose of this study was to evaluate the effects of Coca-Cola and Schweppes Limón on bond strength, adhesive remnant, and microleakage beneath brackets. One hundred and twenty upper central incisor brackets were bonded to bovine incisors and divided into three groups: (1) Control, (2) Coca-Cola, and (3) Schweppes Limón. The teeth were submerged in the drinks three times a day for 15 minutes over a 15 day period. Shear bond strength (SBS) was measured with a universal testing machine, and adhesive remnant evaluated using image analysis equipment. Microleakage at the enamel-adhesive and adhesive-bracket interfaces was determined using methylene blue. One hundred and eight teeth were used for scanning electron microscopy to determine the effect of the drinks on intact and sealed enamel. SBS and adhesive remnant data were analysed using the Kruskal-Wallis test (P 0.05). Microleakage at the enamel-adhesive interface for groups 2 and 3 was significantly greater than for group 1 (P Coca-Cola and Schweppes Limón did not affect the SBS of brackets or the adhesive remnant.

  18. CARIOSTATIC EFFECT AND FLUORIDE RELEASE FROM A VISIBLE LIGHT-CURING ADHESIVE FOR BONDING OF ORTHODONTIC BRACKETS

    NARCIS (Netherlands)

    OGAARD, B; REZKLEGA, F; RUBEN, J; ARENDS, J

    1992-01-01

    This study was designed to investigate the cariostatic potential in vivo of a visible light-curing adhesive for the bonding of orthodontic brackets. The fluoride release of the adhesive in water and saliva was also measured. Ten orthodontic patients with premolars to be extracted participated. One b

  19. CARIOSTATIC EFFECT AND FLUORIDE RELEASE FROM A VISIBLE LIGHT-CURING ADHESIVE FOR BONDING OF ORTHODONTIC BRACKETS

    NARCIS (Netherlands)

    OGAARD, B; REZKLEGA, F; RUBEN, J; ARENDS, J

    This study was designed to investigate the cariostatic potential in vivo of a visible light-curing adhesive for the bonding of orthodontic brackets. The fluoride release of the adhesive in water and saliva was also measured. Ten orthodontic patients with premolars to be extracted participated. One

  20. In vitro Effects of a Neutral Fluoride Agent on Shear Bond Strength and Microleakage of Orthodontic Brackets

    Directory of Open Access Journals (Sweden)

    Farzaneh Ahrari

    2014-06-01

    Full Text Available Introduction: This study aimed to evaluate the effect of pretreatment with a neutral fluoride agent on shear bond strength (SBS and microleakage of orthodontic brackets, and to investigate any significant relationship between SBS and microleakage. Methods: Forty intact premolars were selected and randomly divided into 2 groups. Group 1 served as the control, while group 2 underwent treatment with a 2% sodium fluoride (NaF gel, which was applied on the enamel surface for 4 minutes before etching. After bonding orthodontic brackets, the teeth were immersed for 12 hours in methylen blue dye, followed by mounting in acrylic resin. Shear bond strength was determined using an Instron Universal Testing Machine and the amount of microleakage and the adhesive remnant index (ARI were assessed under a stereomicroscope. Results: The mean SBS and microleakage beneath metal brackets were not significantly different among the control and NaF-treated groups (P>0.05. Furthermore, no significant correlation was found between SBS and microleakage (r=-0.04, P=0.796. The ARI scores revealed that in both groups, most of the adhesive remained on the enamel surface after debonding. Conclusions: It may be concluded that pretreatment of enamel with 2% NaF prior to the bonding procedure does not significantly affect microleakage and SBS of orthodontic brackets and thus, it can be recommended as a suitable approach to reduce the incidence of white spot lesions in orthodontically treated patients, especially those at high risk of caries formation.  

  1. Plaque accumulation and Streptococcus mutans levels around self-ligating bracket clips and elastomeric modules: A randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Dhaval Fadia

    2015-01-01

    Full Text Available Aim: To determine the effect of two different ligating systems that is, elastomeric modules and self-ligating (SL bracket systems (Smartclip - 3M Unitek with respect to harboring bacterial plaque in fixed orthodontic treatment. Objectives: To assess, evaluate, and compare the amount of plaque accumulation and Streptococcus mutans colonization around elastomeric ligation and SL clips in the smart clip appliance. Materials and Methods: A total of 111 orthodontic patients scheduled for fixed orthodontic treatments were selected for this split maxillary arch study. All the patients were bonded with smart-clip (3M Unitek SL brackets, and the wire was placed into the bracket slots, on the randomly selected hemi arch, elastomeric modules were placed for the study to be conducted. Microbial and periodontal plaque accumulation was recorded at 3-time intervals post ligation. Plaque index-by Silness and Loe, modified Quigely Hein index, bleeding on probing were evaluated, and biofilm was collected from the tooth surface after 30 days and placed in petri dishes containing Mitis Salivarius agar for bacterial culturing. Result: It was observed that the side where ligation was done with elastomeric modules accumulated more plaque and increase in S. mutans colony forming units as compared to the side without external ligation (P < 0.05. Conclusion: Reduced bacterial colonization and better plaque control was seen with SL orthodontic bracket appliance system as compared to conventional ligation method.

  2. CARIOSTATIC EFFECT AND FLUORIDE RELEASE FROM A VISIBLE LIGHT-CURING ADHESIVE FOR BONDING OF ORTHODONTIC BRACKETS

    NARCIS (Netherlands)

    OGAARD, B; REZKLEGA, F; RUBEN, J; ARENDS, J

    1992-01-01

    This study was designed to investigate the cariostatic potential in vivo of a visible light-curing adhesive for the bonding of orthodontic brackets. The fluoride release of the adhesive in water and saliva was also measured. Ten orthodontic patients with premolars to be extracted participated. One b

  3. Preliminary study on direct manufacturing of customized lingual brackets by selective laser melting%选区激光熔化直接成型个性化舌侧托槽的研究

    Institute of Scientific and Technical Information of China (English)

    孔卫东; 王淑范; 王迪; 卢建斌; 杨永强

    2012-01-01

    In order to investigate the feasibility of direct manufacturing customized lingual brackets by selective laser melting, firstly, a 3-D scanner was used to acquire and reconstruct teeth model, which was based on the customized lingual brackets designing with 3-D software; then customized metal lingual brackets were directly manufactured with a self-developed selective laser melting apparatus; finally the slot width of the bracket on front teeth was measured. The analysis shows that the teeth model obtained from the three dimensional laser scanner can meet the requirements for customized lingual brackets designing, and customized metal lingual brackets that can well fitted with teeth model can be produced precisely by selective laser melting process. Compared with the designed value 0. 460mm on CAD model, the slot width of the front teeth was measured 0. 471mm ±0. 009mm. The research proves it is feasible to manufacture precise and well fitted customized metal lingual brackets by means of selective laser melting technique.%为了探讨应用选区激光熔化快速成型技术直接制造个性化金属舌侧托槽的可行性,采用3维激光扫描仪采集与重建牙颌模型数据,并以该数字模型为基础,应用3维软件进行了个性化舌侧托槽的CAD设计,再通过自主研发的选区激光熔化快速成型机直接制造出个性化金属舌侧托槽,并对托槽的直接成型质量进行了理论分析和实验验证.结果表明,3维激光扫描仪获得的牙颌模型数据可以满足个性化舌侧托槽设计要求;应用选区激光熔化技术能够制造出与实际牙颌模型相一致的个性化舌侧托槽,取得了个性化前牙槽沟宽度为0.471mm±0.009mm数据,前牙槽沟宽度CAD设计值为0.460mm,两者间没有统计学上的差异(p>0.05).这一结果对选区激光熔化技术直接制造个性化金属舌侧托槽的实际应用是有帮助的.

  4. Review of Physical Based Monitoring Techniques for Condition Assessment of Corrosion in Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Ying Lei

    2013-01-01

    Full Text Available Monitoring the condition of steel corrosion in reinforced concrete (RC is imperative for structural durability. In the past decades, many electrochemistry based techniques have been developed for monitoring steel corrosion. However, these electrochemistry techniques can only assess steel corrosion through monitoring the surrounding concrete medium. As alternative tools, some physical based techniques have been proposed for accurate condition assessment of steel corrosion through direct measurements on embedded steels. In this paper, some physical based monitoring techniques developed in the last decade for condition assessment of steel corrosion in RC are reviewed. In particular, techniques based on ultrasonic guided wave (UGW and Fiber Bragg grating (FBG are emphasized. UGW based technique is first reviewed, including important characters of UGW, corrosion monitoring mechanism and feature extraction, monitoring corrosion induced deboning, pitting, interface roughness, and influence factors. Subsequently, FBG for monitoring corrosion in RC is reviewed. The studies and application of the FBG based corrosion sensor developed by the authors are presented. Other physical techniques for monitoring corrosion in RC are also introduced. Finally, the challenges and future trends in the development of physical based monitoring techniques for condition assessment of steel corrosion in RC are put forward.

  5. Beatification: Flattening the Poisson Bracket for Two-Dimensional Fluid and Plasma Theories

    CERN Document Server

    Viscondi, Thiago F; Morrison, Philip J

    2016-01-01

    A perturbative method called beatification is presented for a class of two-dimensional fluid and plasma theories. The Hamiltonian systems considered, namely the Euler, Vlasov-Poisson, Hasegawa-Mima, and modified Hasegawa-Mima equations, are naturally described in terms of noncanonical variables. The beatification procedure amounts to finding the correct transformation that removes the explicit variable dependence from a noncanonical Poisson bracket and replaces it with a fixed dependence on a chosen state in phase space. As such, beatification is a major step toward casting the Hamiltonian system in its canonical form, thus enabling or facilitating the use of analytical and numerical techniques that require or favor a representation in terms of canonical, or beatified, Hamiltonian variables.

  6. Tradespace Assessment: Thermal Strain Modeling Comparison Of Multiple Clothing Configurations Based On Different Environmental Conditions

    Science.gov (United States)

    2017-02-01

    The investigators have adhered to the policies for protection of human subjects as prescribed in Army Regulation 70-25 and SECNAVINST 3900.39D, and... body temperatures (Tc) of 38.5°C in three environmental conditions 10 5 Comparison of Undergarment vs. No Undergarment Configurations (Group 2...predicted times to reach critical core body temperatures (Tc) of 38.5°C in three environmental conditions 10 6 Comparison of ACS-Based Configurations

  7. Conditional Autoregregressive Range (CARR) Based Volatility Spillover Index For the Eurozone Markets

    OpenAIRE

    Bayraci, Selcuk; Demiralay, Sercan

    2013-01-01

    : We examine the volatility spillovers among major Eurozone countries employing the Diebold and Yilmaz (2012) model with time-varying conditional ranges generated from conditional autoregressive range (CARR) model of Chou (2005). The empirical findings, based on a data set covering a fifteen year period (1998-2013), suggest a total volatility spillover index in a very high degree. 74.9% of total volatility in the Eurozone markets is attributed to spillover effects from other markets. Moreover...

  8. Estimation and Prediction of the Condition of the Vehicle Engine Based on the Correlation Dimension

    Institute of Scientific and Technical Information of China (English)

    LiuChun; ZhangLaibin; WangZhaohui

    2004-01-01

    This paper applies the fractal dimension as a characteristic to describe the engine's operating condition and its developmental trend. A correlation dimension is one of the quantities that are usually used to characterize a strange attractor. With the operation of the phase space reconstruction, respective correlation dimensions of a series of vibration signals obtained under different conditions are calculated to find the intrinsic relationship between the indicator and the operating condition. The experiment result shows that the correlation dimension is sensitive to the condition evolution and convenient for the identification of abnormal operational states. In advanced prognostic algorithm based on the BP neural network is then applied on the correlation dimensions to predict the short-term running conditions in order to avoid severe faults and realize in-time maintenance. Experimental results are presented to illustrate the proposed methodology.

  9. Condition Monitoring for DC-link Capacitors Based on Artificial Neural Network Algorithm

    DEFF Research Database (Denmark)

    Soliman, Hammam Abdelaal Hammam; Wang, Huai; Gadalla, Brwene Salah Abdelkarim

    2015-01-01

    In power electronic systems, capacitor is one of the reliability critical components . Recently, the condition monitoring of capacitors to estimate their health status have been attracted by the academic research. Industry applications require more reliable power electronics products...... with preventive maintenance. However, the existing capacitor condition monitoring methods suffer from either increased hardware cost or low estimation accuracy, being the challenges to be adopted in industry applications. New development in condition monitoring technology with software solutions without extra...... hardware will reduce the cost, and therefore could be more promising for industry applications. A condition monitoring method based on Artificial Neural Network (ANN) algorithm is therefore proposed in this paper. The implementation of the ANN to the DC-link capacitor condition monitoring in a back...

  10. Web-Based Mindfulness Interventions for People With Physical Health Conditions: Systematic Review.

    Science.gov (United States)

    Toivonen, Kirsti I; Zernicke, Kristin; Carlson, Linda E

    2017-08-31

    Mindfulness-based interventions (MBIs) are becoming increasingly popular for helping people with physical health conditions. Expanding from traditional face-to-face program delivery, there is growing interest in Web-based application of MBIs, though Web-based MBIs for people with physical health conditions specifically have not been thoroughly reviewed to date. The objective of this paper was to review Web-based MBIs for people with physical health conditions and to examine all outcomes reported (eg, efficacy or effectiveness for physical changes or psychological changes; feasibility). Databases PubMed, PsycINFO, Science Direct, CINAHL Plus, and Web of Science were searched. Full-text English papers that described any Web-based MBI, examining any outcome, for people with chronic physical health conditions were included. Randomized, nonrandomized, controlled, and uncontrolled trials were all included. Extracted data included intervention characteristics, population characteristics, outcomes, and quality indicators. Intervention characteristics (eg, synchronicity and guidance) were examined as potential factors related to study outcomes. Of 435 publications screened, 19 published papers describing 16 studies were included. They examined Web-based MBIs for people with cancer, chronic pain or fibromyalgia, irritable bowel syndrome (IBS), epilepsy, heart disease, tinnitus, and acquired brain injury. Overall, most studies reported positive effects of Web-based MBIs compared with usual care on a variety of outcomes including pain acceptance, coping measures, and depressive symptoms. There were mixed results regarding the effectiveness of Web-based MBIs compared with active control treatment conditions such as cognitive behavioral therapy. Condition-specific symptoms (eg, cancer-related fatigue and IBS symptoms) targeted by treatment had the largest effect size improvements following MBIs. Results are inconclusive regarding physical variables. Preliminary evidence suggests

  11. Introducing passive acoustic filter in acoustic based condition monitoring: Motor bike piston-bore fault identification

    Science.gov (United States)

    Jena, D. P.; Panigrahi, S. N.

    2016-03-01

    Requirement of designing a sophisticated digital band-pass filter in acoustic based condition monitoring has been eliminated by introducing a passive acoustic filter in the present work. So far, no one has attempted to explore the possibility of implementing passive acoustic filters in acoustic based condition monitoring as a pre-conditioner. In order to enhance the acoustic based condition monitoring, a passive acoustic band-pass filter has been designed and deployed. Towards achieving an efficient band-pass acoustic filter, a generalized design methodology has been proposed to design and optimize the desired acoustic filter using multiple filter components in series. An appropriate objective function has been identified for genetic algorithm (GA) based optimization technique with multiple design constraints. In addition, the sturdiness of the proposed method has been demonstrated in designing a band-pass filter by using an n-branch Quincke tube, a high pass filter and multiple Helmholtz resonators. The performance of the designed acoustic band-pass filter has been shown by investigating the piston-bore defect of a motor-bike using engine noise signature. On the introducing a passive acoustic filter in acoustic based condition monitoring reveals the enhancement in machine learning based fault identification practice significantly. This is also a first attempt of its own kind.

  12. Objective measures for predicting speech intelligibility in noisy conditions based on new band-importance functions.

    Science.gov (United States)

    Ma, Jianfen; Hu, Yi; Loizou, Philipos C

    2009-05-01

    The articulation index (AI), speech-transmission index (STI), and coherence-based intelligibility metrics have been evaluated primarily in steady-state noisy conditions and have not been tested extensively in fluctuating noise conditions. The aim of the present work is to evaluate the performance of new speech-based STI measures, modified coherence-based measures, and AI-based measures operating on short-term (30 ms) intervals in realistic noisy conditions. Much emphasis is placed on the design of new band-importance weighting functions which can be used in situations wherein speech is corrupted by fluctuating maskers. The proposed measures were evaluated with intelligibility scores obtained by normal-hearing listeners in 72 noisy conditions involving noise-suppressed speech (consonants and sentences) corrupted by four different maskers (car, babble, train, and street interferences). Of all the measures considered, the modified coherence-based measures and speech-based STI measures incorporating signal-specific band-importance functions yielded the highest correlations (r=0.89-0.94). The modified coherence measure, in particular, that only included vowel/consonant transitions and weak consonant information yielded the highest correlation (r=0.94) with sentence recognition scores. The results from this study clearly suggest that the traditional AI and STI indices could benefit from the use of the proposed signal- and segment-dependent band-importance functions.

  13. Evaluation of the influence of dental bleaching with 35% hydrogen peroxide in orthodontic bracket shear bond strength

    Directory of Open Access Journals (Sweden)

    Marcus Vinicius Neiva Nunes do Rego

    2013-04-01

    Full Text Available OBJECTIVE: The purpose of this study was to evaluate, in vitro, the bond strength of brackets bonded to premolars previously subjected to bleaching with a 35% hydrogen peroxide. METHODS: Twenty one healthy premolars were selected and randomly divided into three groups (n = 7. Group I (G1 included teeth that were not submitted to bleaching. The enamel surfaces of Groups II (G2 and III (G3 were submitted to a bleaching process with 35% hydrogen peroxide (Whiteness HP Maxx. On Group II (G2, after bleaching, the teeth were stored for 24 hours in distilled water at 98.6 ºF, and then, premolar metallic brackets were bonded using Transbond XT (3M resin. Group III (G3 was submitted to the same procedure seven days after bleaching. After bonding, all teeth were stored in distilled water at 98.6 ºF for 24 hours. All groups were submitted to a traction test using an EMIC DL2000 universal testing machine at a speed of 0.5 mm/min. RESULTS AND CONCLUSION: The bracket resistance to debonding was compared between the groups by the Kruskal-Wallis nonparametric test (p < 0.05 and it was verified that the bleaching agent significantly reduced bracket adhesion when bonded 24 hours after bleaching. However, seven days after bleaching, there was no significant difference on the resistance to debonding among groups G1 (19,52 kgf and G3 (18,44 kgf, meaning that it is necessary to wait longer after bleaching to bond brackets.

  14. Streptococcus mutans forms xylitol-resistant biofilm on excess adhesive flash in novel ex-vivo orthodontic bracket model.

    Science.gov (United States)

    Ho, Cindy S F; Ming, Yue; Foong, Kelvin W C; Rosa, Vinicius; Thuyen, Truong; Seneviratne, Chaminda J

    2017-04-01

    During orthodontic bonding procedures, excess adhesive is invariably left on the tooth surface at the interface between the bracket and the enamel junction; it is called excess adhesive flash (EAF). We comparatively evaluated the biofilm formation of Streptococcus mutans on EAF produced by 2 adhesives and examined the therapeutic efficacy of xylitol on S mutans formed on EAF. First, we investigated the biofilm formation of S mutans on 3 orthodontic bracket types: stainless steel preadjusted edgewise, ceramic preadjusted edgewise, and stainless steel self-ligating. Subsequently, tooth-colored Transbond XT (3M Unitek, Monrovia, Calif) and green Grengloo (Ormco, Glendora, Calif) adhesives were used for bonding ceramic brackets to extracted teeth. S mutans biofilms on EAF produced by the adhesives were studied using the crystal violet assay and scanning electron microscopy. Surface roughness and surface energy of the EAF were examined. The therapeutic efficacies of different concentrations of xylitol were tested on S mutans biofilms. Significantly higher biofilms were formed on the ceramic preadjusted edgewise brackets (P = 0.003). Transbond XT had significantly higher S mutans biofilms compared with Grengloo surfaces (P = 0.007). There was no significant difference in surface roughness between Transbond XT and Grengloo surfaces (P >0.05). Surface energy of Transbond XT had a considerably smaller contact angle than did Grengloo, suggesting that Transbond XT is a more hydrophilic material. Xylitol at low concentrations had no significant effect on the reduction of S mutans biofilms on orthodontic adhesives (P = 0.016). Transbond XT orthodontic adhesive resulted in more S mutans biofilm compared with Grengloo adhesive on ceramic brackets. Surface energy seemed to play a more important role than surface roughness for the formation of S mutans biofilm on EAF. Xylitol does not appear to have a therapeutic effect on mature S mutans biofilm. Copyright © 2017 American

  15. Does a chitosan-containing dentifrice prevent demineralization around orthodontic brackets?

    Science.gov (United States)

    Uysal, Tancan; Akkurt, Meltem Derya; Amasyali, Mihri; Ozcan, Suat; Yagci, Ahmet; Basak, Feridun; Sagdic, Deniz

    2011-03-01

    To test the null hypothesis that there is no significant difference between the chitosan-containing and conventional nonfluoridated dentifrices in inhibition of enamel demineralization around orthodontic brackets. Sixteen orthodontic patients who were scheduled to have extraction of four first premolars for orthodontic reasons were divided into two groups after the power of the study was estimated. Patients in the experimental group were instructed to use chitosan-containing dentifrice (AloeDent), and patients in the control group were instructed to use nonfluoridated dentifrice (Sensodyne Mint). After 60 days, the teeth were extracted and longitudinally sectioned. The demineralization was assessed by cross-sectional microhardness. The determinations were made at the bracket edge cementing limits and at occlusal and cervical points, 100 µm and 200 µm away from the edge. In all these positions, indentations were made at depths of 10, 20, 30, 50, 70, and 90 µm from the enamel surface. Analysis of variance (ANOVA) and Tukey test were used for statistical evaluation at P < .05 level. ANOVA showed statistically significant differences for the factors of dentifrice type, position, and depth (P  =  .000). Statistically significant differences for microhardness values between two tested dentifrices were observed up to 20 µm of depth from the enamel surface (P < .05). Lower microhardness values were found for nonfluoridated dentifrice. Significant microhardness differences were also determined between materials at occlusal and cervical 0 µm positions (P < .05). At these positions, chitosan-containing dentifrice showed lower demineralization than the control. Chitosan-containing dentifrice may reduce the enamel decalcification found in patients with poor oral hygiene. The null hypothesis is rejected.

  16. Influence of surface treatment on shear bond strength of orthodontic brackets

    Directory of Open Access Journals (Sweden)

    Ione Helena Vieira Portella Brunharo

    2013-06-01

    Full Text Available INTRODUCTION: The shear bond strength of orthodontic brackets bonded to micro-hybrid and micro-particulate resins under different surface treatment methods was assessed. METHODS: Two hundred and eighty test samples were divided into 28 groups (n = 10, where 140 specimens were filled with Durafill micro-particulate resin and 140 with Charisma composite. In 140 samples, a coupling agent (silane was applied. The surface treatment methods were: Phosphoric and hydrofluoric acid etching, sodium bicarbonate and aluminum oxide blasting, stone and burs. A Universal Instron Machine was used to apply an occlusal shear force directly to the resin composite bracket surface at a speed of 0.5 mm/min. The means were compared using analysis of variance and multivariate regression to assess the interaction between composites and surface treatment methods. RESULTS: Means and standard deviations for the groups were: Sodium bicarbonate jet 11.27±2.78; burs 9.26±3.01; stone 7.95±3.67; aluminum oxide blasting 7.04±3.21; phosphoric acid 5.82±1.90; hydrofluoric acid 4.54±2.87, and without treatment 2.75±1.49. An increase of 1.94 MPa in shear bond strength was seen in Charisma groups. Silane agent application reduced the Charisma shear bond strength by 0.68 Mpa, but increased Durafill means for bicarbonate blasting (0.83, burs (0.98 and stone drilling (0.46. CONCLUSION: The sodium bicarbonate blasting, burs and stone drilling methods produced adequate shear bond strength and may be suitable for clinical use. The Charisma micro hybrid resin composite showed higher shear bond means than Durafill micro particle composite.

  17. Timing considerations on the shear bond strength of orthodontic brackets after topical fluoride varnish applications

    Science.gov (United States)

    Cossellu, Gianguido; Lanteri, Valentina; Butera, Andrea; Laffi, Nicola; Merlini, Alberto; Farronato, Giampietro

    2017-01-01

    Objectives: To assess the best temporal association between the application of a fluoride varnish on enamel and bonding procedures. Materials and Methods: Eighty mandibular bovine incisors were used. Teeth were divided into 4 groups (20 per group); Groups 1–3 were treated with fluoride varnish (Fluor Protector, Ivoclar Vivadent, Schaan, Liechtenstein), and Group 4 served as control with no pretreatment. Tooth were stored in deionized water (37°C) and subjected to thermal cycling for 400 (Group 1), 800 (Group 2), and 2500 (Group 3) cycles corresponding, respectively, to 15, 30, and 90 days in order to simulate the three different timing of bracket bonding. Shear bond strength (SBS) was measured using an Instron Universal Testing machine. Tooth surfaces were examined under a stereomicroscope at 10× magnification to assess the amount of adhesive remnant index (ARI). One-way analysis of variance (ANOVA) and Tukey's honestly significant difference post-hoc test were used for the comparison of SBS values between groups (P < 0.05). The Chi-square test was used to examine differences among ARI scores. (P < 0.05). Results: One-way ANOVA and Tukey post-hoc test showed that the SBS of different groups were significantly different and was impacted by different timing of bonding (P < 0.05). The main differences were between the control group (17.02 ± 6.38 MPa) and Group 1 (6.93 ± 4.3 MPa). The ARI scores showed that there were no significant differences between the four tested groups. Conclusions: The SBS of the brackets bonded 15 days after the application of the fluoride was set back to an optimal value. PMID:28197397

  18. The effect of APF-incorporated phosphoric acid etchant on shear bond strength of orthodontic brackets

    Directory of Open Access Journals (Sweden)

    Behnam Khosravanifard

    2011-01-01

    Full Text Available Background: The aim of this study was to evaluate the effect of adding acidulated phosphate fluoride (APF to phosphoric acid etchant on shear bond strength (SBS and adhesive remnant index (ARI of orthodontic brackets bonded to etched teeth. Methods: In this in vitro experimental study, 40 human premolars were etched with 37% phosphoric acid solution (Dentsply blended with 0, 25%, 50%, and 75% fractions of 1.23% APF (Dentsply. The brackets (Mini Dyna Lock, 3M were bonded (Transbond XT, 3M and were subjected to 96 hours of 37°C incubation and thermocycling procedures (2000 cycles, 5-55°C, dwell time = 30 s. Then, they were debonded at 1-mm crosshead speed to measure the SBS. The ARI was estimated at 10× magnification. The data were analyzed using the tests one-way analysis of variance (ANOVA, Tukey, chi-square, one-sample t-test, and Spearman correlation. Results: The SBS of the groups control, 25%, 50%, and 75% APF were 11.90±2.72, 8.01±3.13, 5.40±2.51, and 3.27±2.01 MPa, respectively. Mean ARI scores of these groups were 2.4 (control, 4.3, 4.7, and 4.8, respectively. According to the Tukey′s test, only the mean SBS of the second group (25% was not different from the control group (P=0.091. Conclusion: Adding about 20-25% of 1.23% APF to the phosphoric acid etchant might considerably reduce the amount of residual adhesive, without compromising the SBS.

  19. CONDITION MONITOR OF DEEP-HOLE DRILLING BASED ON MULTI-SENSOR INFORMATION FUSION

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    A condition monitoring method of deep-hole drilling based on multi-sensor information fusion is discussed. The signal of vibration and cutting force are collected when the condition of deep-hole drilling on stainless steel 0Crl7Ni4Cu4Nb is normal or abnormal. Four eigenvectors are extracted on time-domain and frequency-domain analysis of the signals. Then the four eigenvectors are combined and sent to neural networks to dispose. The fusion results indicate that multi-sensor information fusion is superior to single-sensor information, and that cutting force signal can reflect the condition of cutting tool better than vibration signal.

  20. Localization of periodic orbits of autonomous systems based on high-order extremum conditions

    Directory of Open Access Journals (Sweden)

    Starkov Konstantin E.

    2004-01-01

    Full Text Available This paper gives localization and nonexistence conditions of periodic orbits in some subsets of the state space. Mainly, our approach is based on high-order extremum conditions, on high-order tangency conditions of a nonsingular solution of a polynomial system with an algebraic surface, and on some ideas related to algebraically-dependent polynomials. Examples of the localization analysis of periodic orbits are presented including the Blasius equations, the generalized mass action (GMA system, and the mathematical model of the chemical reaction with autocatalytic step.