WorldWideScience

Sample records for brachytherapy utilization rate

  1. Concomitant chemoradiotherapy with high dose rate brachytherapy ...

    African Journals Online (AJOL)

    Concomitant chemoradiotherapy with high dose rate brachytherapy as a definitive treatment modality for locally advanced cervical cancer. T Refaat, A Elsaid, N Lotfy, K Kiel, W Small Jr, P Nickers, E Lartigau ...

  2. Endorectal high dose rate brachytherapy quality assurance

    International Nuclear Information System (INIS)

    Devic, S.; Vuong, T.; Evans, M.; Podgorsak, E.

    2008-01-01

    We describe our quality assurance method for preoperative high dose rate (HDR) brachytherapy of endorectal tumours. Reproduction of the treatment planning dose distribution on a daily basis is crucial for treatment success. Due to the cylindrical symmetry, two types of adjustments are necessary: applicator rotation and dose distribution shift along the applicator axis. (author)

  3. Trends in the Utilization of Brachytherapy in Cervical Cancer in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Han, Kathy, E-mail: Kathy.Han@rmp.uhn.on.ca [Radiation Medicine Program, Princess Margaret Hospital, University Health Network, Toronto, Ontario (Canada); Milosevic, Michael; Fyles, Anthony [Radiation Medicine Program, Princess Margaret Hospital, University Health Network, Toronto, Ontario (Canada); Pintilie, Melania [Department of Biostatistics, Princess Margaret Hospital, Toronto, Ontario (Canada); Viswanathan, Akila N. [Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital, Boston, Massachusetts (United States)

    2013-09-01

    Purpose: To determine the trends in brachytherapy use in cervical cancer in the United States and to identify factors and survival benefits associated with brachytherapy treatment. Methods and Materials: Using the Surveillance, Epidemiology, and End Results (SEER) database, we identified 7359 patients with stages IB2-IVA cervical cancer treated with external beam radiation therapy (EBRT) between 1988 and 2009. Propensity score matching was used to adjust for differences between patients who received brachytherapy and those who did not from 2000 onward (after the National Cancer Institute alert recommending concurrent chemotherapy). Results: Sixty-three percent of the 7359 women received brachytherapy in combination with EBRT, and 37% received EBRT alone. The brachytherapy utilization rate has decreased from 83% in 1988 to 58% in 2009 (P<.001), with a sharp decline of 23% in 2003 to 43%. Factors associated with higher odds of brachytherapy use include younger age, married (vs single) patients, earlier years of diagnosis, earlier stage and certain SEER regions. In the propensity score-matched cohort, brachytherapy treatment was associated with higher 4-year cause-specific survival (CSS; 64.3% vs 51.5%, P<.001) and overall survival (OS; 58.2% vs 46.2%, P<.001). Brachytherapy treatment was independently associated with better CSS (hazard ratio [HR], 0.64; 95% confidence interval [CI], 0.57-0.71), and OS (HR 0.66; 95% CI, 0.60 to 0.74). Conclusions: This population-based analysis reveals a concerning decline in brachytherapy utilization and significant geographic disparities in the delivery of brachytherapy in the United States. Brachytherapy use is independently associated with significantly higher CSS and OS and should be implemented in all feasible cases.

  4. Accelerated partial breast irradiation utilizing balloon brachytherapy techniques

    International Nuclear Information System (INIS)

    Strauss, Jonathan B.; Dickler, Adam

    2009-01-01

    To overcome the barriers to BCT, methods of PBI in the setting of breast conservation have been explored. The method of PBI with the longest published follow-up is multi-catheter interstitial brachytherapy. Balloon-based brachytherapy with the MammoSite brachytherapy applicator was designed to simplify the brachytherapy procedure for PBI, enhance the reproducibility of the dosimetry, and improve patient comfort. The rates of local recurrence following PBI with the MammoSite applicator have been low, but there are few published reports and follow-up has been relatively short. The cosmetic outcomes and toxicity of MammoSite PBI are comparable to those seen after multicatheter-based PBI. Additional methods of balloon brachytherapy, including Xoft and SenoRx Contura have been developed. Finally, long-term follow-up after PBI is important for the welfare of individual patients and in order to establish the efficacy, late toxicity and cosmetic outcomes of this technique.

  5. Brachytherapy treatment with high dose rate

    International Nuclear Information System (INIS)

    Santana Rodriguez, Sergio Marcelino; Rodriguez Rodriguez, Lissi Lisbet; Ciscal Chiclana, Onelio Alberto

    2009-01-01

    Retrospectively analyze results and prognostic factors of cervical cancer patients treated with radio concomitant cisplatin-based chemotherapy, radiation therapy combined modality. Methods: From January 2003 to December 2007, 198 patients with invasive cervical cancer were treated at the Oncology Department of Hospital Robau Celestino Hernandez (brachytherapy performed at INOR). The most common age group was 31 to 40 years. The histology in squamous cell carcinoma accounted for 84.3% of cases. The treatment consisted of external pelvic irradiation and vaginal brachytherapy, high dose rate. Concomitant chemotherapy consisted of cisplatin 40 mg/m2 weekly with a maximum of 70 mg for 5 weeks. Results: 66.2% of patients completed 5 cycles of chemotherapy. The median overall survival was 39 months, overall survival, disease-free survival and survival free of locoregional recurrence at 5 years of 78%, 76% and 78.6% respectively .. We found that clinical stage, histological type (adenocarcinoma worst outcome) were statistically related to level of response. Conclusions: Treatment with external pelvic radiation, brachytherapy and concurrent weekly cisplatin in patients with stage IIIB cervical cancer is feasible in the Chilean public health system, well tolerated and results comparable to international literature. (Author)

  6. Biology of dose rate in brachytherapy

    International Nuclear Information System (INIS)

    Brenner, David J.

    1995-01-01

    Purpose: This course is designed for practitioners and beginners in brachytherapy. The aim is to review biological principles underlying brachytherapy, to understand why current treatment regimes are the way they are, and to discuss what the future may hold in store. Brachytherapy has a long history. It was suggested as long ago as 1903 by Alexander Graham Bell, and the optimal application of this technique has been a subject of debate ever since. 'Brachy' means 'short', and the essential features of conventional brachytherapy are: positioning of the source a short distance from, or in, the tumor, allowing good dose distributions; short overall treatment times, to counter tumor repopulation; low dose rate, enabling a good therapeutic advantage between tumor control and damage to late-responding tissue. The advantages of good dose distributions speak for themselves; in some situations, as we shall see, computer-based dose optimization can be used to improve them still further. The advantages of short overall times stem from the fact that accelerated repopulation of the tumor typically begins a few weeks after the start of a radiation treatment. If all the radiation can be crammed in before that time, the risks of tumor repopulation can be considerably reduced. In fact even external-beam radiotherapy is moving in this direction, with the use of highly accelerated protocols. The advantages of low dose rate stem from the differential response to fractionation of early- and late-responding tissues. Essentially, lowering the dose rate spares late-responding tissue more than it does early-responding tissue such as tumors. We shall also discuss some recent innovations in the context of the general principles that have been outlined. For example, High dose rate brachytherapy, particularly for the uterine cervix: Does it work? If so, when and why? Use of Ir-192 sources, with a half life of 70 days: Should corrections be made for changing biological effectiveness as the dose

  7. Utilization and Outcomes of Breast Brachytherapy in Younger Women

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Grace L. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Huo, Jinhai [Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Giordano, Sharon H. [Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Hunt, Kelly K. [Department of Surgical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Buchholz, Thomas A. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Smith, Benjamin D., E-mail: bsmith3@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2015-09-01

    Purpose: To directly compare (1) radiation treatment utilization patterns; (2) risks of subsequent mastectomy; and (3) costs of radiation treatment in patients treated with brachytherapy versus whole-breast irradiation (WBI), in a national, contemporary cohort of women with incident breast cancer, aged 64 years and younger. Methods and Materials: Using MarketScan health care claims data, we identified 45,884 invasive breast cancer patients (aged 18-64 years), treated from 2003 to 2010 with lumpectomy, followed by brachytherapy (n=3134) or whole-breast irradiation (n=42,750). We stratified patients into risk groups according to age (Age<50 vs Age≥50) and endocrine therapy status (Endocrine− vs Endocrine+). “Endocrine+” patients filled an endocrine therapy prescription within 1 year after lumpectomy. Pathologic hormone receptor status was not available in this dataset. In brachytherapy versus WBI patients, utilization trends and 5-year subsequent mastectomy risks were compared. Stratified, adjusted subsequent mastectomy risks were calculated using proportional hazards regression. Results: Brachytherapy utilization increased from 2003 to 2010: in patients Age<50, from 0.6% to 4.9%; patients Age≥50 from 2.2% to 11.3%; Endocrine− patients, 1.3% to 9.4%; Endocrine+ patients, 1.9% to 9.7%. Age influenced treatment selection more than endocrine status: 17% of brachytherapy patients were Age<50 versus 32% of WBI patients (P<.001); whereas 41% of brachytherapy patients were Endocrine–versus 44% of WBI patients (P=.003). Highest absolute 5-year subsequent mastectomy risks occurred in Endocrine−/Age<50 patients (24.4% after brachytherapy vs 9.0% after WBI (hazard ratio [HR] 2.18, 95% confidence interval [CI] 1.37-3.47); intermediate risks in Endocrine−/Age≥50 patients (8.6% vs 4.9%; HR 1.76, 95% CI 1.26-2.46); and lowest risks in Endocrine+ patients of any age: Endocrine+/Age<50 (5.5% vs 4.5%; HR 1.18, 95% CI 0.61-2.31); Endocrine+/Age≥50 (4.2% vs 2

  8. A review of the clinical experience in pulsed dose rate brachytherapy

    NARCIS (Netherlands)

    Balgobind, Brian V.; Koedooder, Kees; Ordoñez Zúñiga, Diego; Dávila Fajardo, Raquel; Rasch, Coen R. N.; Pieters, Bradley R.

    2015-01-01

    Pulsed dose rate (PDR) brachytherapy is a treatment modality that combines physical advantages of high dose rate (HDR) brachytherapy with the radiobiological advantages of low dose rate brachytherapy. The aim of this review was to describe the effective clinical use of PDR brachytherapy worldwide in

  9. Treatment of the prostate cancer with high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Martinez, Alvaro; Torres Silva, Felipe

    2002-01-01

    The prostate cancer treatment in early stages is controversial. The high dose rate brachytherapy has been used like monotherapy or boost with external beam radiotherapy in advanced disease. This paper describes the technique and the advantages over other modalities

  10. High dose rate brachytherapy for superficial cancer of the esophagus

    International Nuclear Information System (INIS)

    Maingon, Philippe; D'Hombres, Anne; Truc, Gilles; Barillot, Isabelle; Michiels, Christophe; Bedenne, Laurent; Horiot, Jean Claude

    2000-01-01

    Purpose: We analyzed our experience with external radiotherapy, combined modality treatment, or HDR brachytherapy alone to limited esophageal cancers. Methods and Materials: From 1991 to 1996, 25 patients with limited superficial esophagus carcinomas were treated by high dose rate brachytherapy. The mean age was 63 years (43-86 years). Five patients showed superficial local recurrence after external radiotherapy. Eleven patients without invasion of the basal membrane were staged as Tis. Fourteen patients with tumors involving the submucosa without spreading to the muscle were staged as T1. Treatment consisted of HDR brachytherapy alone in 13 patients, external radiotherapy and brachytherapy in 8 cases, and concomitant chemo- and radiotherapy in 4 cases. External beam radiation was administered to a total dose of 50 Gy using 2 Gy daily fractions in 5 weeks. In cases of HDR brachytherapy alone (13 patients), 6 applications were performed once a week. Results: The mean follow-up is 31 months (range 24-96 months). Twelve patients received 2 applications and 13 patients received 6 applications. Twelve patients experienced a failure (48%), 11/12 located in the esophagus, all of them in the treated volume. One patient presented an isolated distant metastasis. In the patients treated for superficial recurrence, 4/5 were locally controlled (80%) by brachytherapy alone. After brachytherapy alone, 8/13 patients were controlled (61%). The mean disease-free survival is 14 months (1-36 months). Overall survival is 76% at 1 year, 37% at 2 years, and 14% at 3 years. Overall survival for Tis patients is 24% vs. 20% for T1 (p 0.83). Overall survival for patients treated by HDR brachytherapy alone is 43%. One patient presented with a fistula with local failure after external radiotherapy and brachytherapy. Four stenosis were registered, two were diagnosed on barium swallowing without symptoms, and two required dilatations. Conclusion: High dose rate brachytherapy permits the treating

  11. Imaging method for monitoring delivery of high dose rate brachytherapy

    Science.gov (United States)

    Weisenberger, Andrew G; Majewski, Stanislaw

    2012-10-23

    A method for in-situ monitoring both the balloon/cavity and the radioactive source in brachytherapy treatment utilizing using at least one pair of miniature gamma cameras to acquire separate images of: 1) the radioactive source as it is moved in the tumor volume during brachytherapy; and 2) a relatively low intensity radiation source produced by either an injected radiopharmaceutical rendering cancerous tissue visible or from a radioactive solution filling a balloon surgically implanted into the cavity formed by the surgical resection of a tumor.

  12. Dosimetry in high dose rate endoluminal brachytherapy

    International Nuclear Information System (INIS)

    Uno, Takashi; Kotaka, Kikuo; Itami, Jun

    1994-01-01

    In endoluminal brachytherapy for the tracheobronchial tree, esophagus, and bile duct, a reference point for dose calculation has been often settled at 1 cm outside from the middle of source travel path. In the current study, a change in the ratio of the reference point dose on the convex to concave side (Dq/Dp) was calculated, provided the source travel path bends as is the case in most endoluminal brachytherapies. Point source was presumed to move stepwise at 1 cm interval from 4 to 13 locations. Retention time at each location was calculated by personal computer so as to deliver equal dose at 1 cm from the linear travel path. With the retention time remaining constant, the change of Dq/Dp was assessed by bending the source travel path. Results indicated that the length of the source travel path and radius of its curve influenced the pattern of change in Dq/Dp. Therefore, it was concluded that the difference in reference dose on the convex and concave side of the curved path is not negligible under certain conditions in endoluminal brachytherapy. In order to maintain the ratio more than 0.9, relatively greater radius was required when the source travel path was decreased. (author)

  13. Transit dose calculation in high dose rate brachytherapy (HDR ...

    African Journals Online (AJOL)

    Transit doses around a high dose rate 192Ir brachytherapy source were calculated using Sievert Integral at positions where the moving source was located exactly between two adjacent dwell positions. The correspond-ing transit dose rates were obtained by using energy absorption coefficients. Discrete step sizes of 0.25 ...

  14. Braquiterapia de alta taxa de dose no Brasil High-dose rate brachytherapy in Brazil

    Directory of Open Access Journals (Sweden)

    Sérgio Carlos Barros Esteves

    2004-10-01

    Full Text Available A braquiterapia de alta taxa de dose foi introduzida em nosso meio em janeiro de 1991. Desde então, houve uma mudança significativa na abordagem das neoplasias malignas em relação às vantagens do novo método, e também resolução da demanda reprimida de braquiterapia para as neoplasias ginecológicas. Nos primeiros dez anos de atividade, o Brasil tratou, em 31 serviços, 26.436 pacientes com braquiterapia, sendo mais de 50% das pacientes portadoras de neoplasias do colo uterino. Este estudo mostra o número e o perfil de pacientes tratados com esse método e a sua distribuição no território nacional, deixando explícito o benefício da braquiterapia de alta taxa de dose para o Brasil.High-dose rate brachytherapy was first introduced in Brazil in January 1991. Significant changes in the management of malignant neoplasms were observed since utilization of high-dose rate brachytherapy. The high number of gynecological patients awaiting for brachytherapy also decreased during this period. In the first ten years 26,436 patients were treated with high-dose rate brachytherapy. More than 50% of these patients presented neoplasms of the uterine cervix. In this study we present the number and profile of the patients treated with high-dose rate brachytherapy as well as the distribution of these patients in the Brazilian territory, proving the benefit of the use of high-dose rate brachytherapy in Brazil.

  15. A review of the clinical experience in pulsed dose rate brachytherapy.

    Science.gov (United States)

    Balgobind, Brian V; Koedooder, Kees; Ordoñez Zúñiga, Diego; Dávila Fajardo, Raquel; Rasch, Coen R N; Pieters, Bradley R

    2015-01-01

    Pulsed dose rate (PDR) brachytherapy is a treatment modality that combines physical advantages of high dose rate (HDR) brachytherapy with the radiobiological advantages of low dose rate brachytherapy. The aim of this review was to describe the effective clinical use of PDR brachytherapy worldwide in different tumour locations. We found 66 articles reporting on clinical PDR brachytherapy including the treatment procedure and outcome. Moreover, PDR brachytherapy has been applied in almost all tumour sites for which brachytherapy is indicated and with good local control and low toxicity. The main advantage of PDR is, because of the small pulse sizes used, the ability to spare normal tissue. In certain cases, HDR resembles PDR brachytherapy by the use of multifractionated low-fraction dose.

  16. Pulsed dose rate brachytherapy – is it the right way?

    Directory of Open Access Journals (Sweden)

    Janusz Skowronek

    2010-10-01

    Full Text Available Pulsed dose rate (PDR-BT treatment is a brachytherapy modality that combines physical advantages of high-doserate (HDR-BT technology (isodose optimization, radiation safety with the radiobiological advantages of low-dose-rate (LDR-BT brachytherapy. Pulsed brachytherapy consists of using stronger radiation source than for LDR-BT and producing series of short exposures of 10 to 30 minutes in every hour to approximately the same total dose in the sameoverall time as with the LDR-BT. Modern afterloading equipment offers certain advantages over interstitial or intracavitaryinsertion of separate needles, tubes, seeds or wires. Isodose volumes in tissues can be created flexibly by a combinationof careful placement of the catheter and the adjustment of the dwell times of the computerized stepping source.Automatic removal of the radiation sources into a shielded safe eliminates radiation exposures to staff and visitors.Radiation exposure is also eliminated to the staff who formerly loaded and unloaded multiplicity of radioactive sources into the catheters, ovoids, tubes etc. This review based on summarized clinical investigations, analyses the feasibility and the background to introduce this brachytherapy technique and chosen clinical applications of PDR-BT.

  17. Brachytherapy. High dose rate brachytherapy - Radiation protection: medical sheet ED 4287

    International Nuclear Information System (INIS)

    Celier, D.; Aubert, B.; Vidal, J.P.; Biau, A.; Lahaye, T.; Gauron, C.; Barret, C.; Boisserie, G.; Branchet, E.; Gambini, D.; Gondran, C.; Le Guen, B.; Guerin, C.; Nguyen, S.; Pierrat, N.; Sarrazin, T.; Donnarieix, D.

    2010-02-01

    After having indicated the required authorization to implement brachytherapy techniques, this document presents the various aspects and measures related to radiation protection when performing high-dose-rate brachytherapy treatments. It presents the concerned personnel, describes the operational process, indicates the associated hazards and the risk related to ionizing radiation, and describes how the risk is to be assessed and how exposure levels are to be determined (elements of risk assessment, delimitation of controlled and monitored areas, personnel classification, and choice of the dose monitoring method). It describes the various components of a risk management strategy (risk reduction, technical measures regarding the installation and the personnel, training and information, prevention and medical monitoring). It briefly presents how risk management is to be assessed, and mentions other related risks (biological risk, handling and posture, handling of heavy loads, mental workload, chemical risk)

  18. Brachytherapy. Pulsed dose rate brachytherapy - Radiation protection: medical sheet ED 4250

    International Nuclear Information System (INIS)

    Celier, D.; Aubert, B.; Vidal, J.P.; Biau, A.; Lahaye, T.; Gauron, C.; Barret, C.; Boisserie, G.; Branchet, E.; Gambini, D.; Gondran, C.; Le Guen, B.; Guerin, C.; Nguyen, S.; Pierrat, N.; Sarrazin, T.; Donnarieix, D.

    2009-06-01

    After having indicated the required authorization to implement brachytherapy techniques, this document presents the various aspects and measures related to radiation protection when performing pulsed-dose-rate brachytherapy treatments. It presents the concerned personnel, describes the operational process, indicates the associated hazards and the risk related to ionizing radiation, and describes how the risk is to be assessed and how exposure levels are to be determined (elements of risk assessment, delimitation of controlled and monitored areas, personnel classification, and choice of the dose monitoring method). It describes the various components of a risk management strategy (risk reduction, technical measures regarding the installation and the personnel, training and information, prevention and medical monitoring). It briefly presents how risk management is to be assessed, and mentions other related risks (biological risk, handling and posture, handling of heavy loads, mental workload, chemical risk)

  19. Radiation safety program in a high dose rate brachytherapy facility

    International Nuclear Information System (INIS)

    Rodriguez, L.V.; Hermoso, T.M.; Solis, R.C.

    2001-01-01

    The use of remote afterloading equipment has been developed to improve radiation safety in the delivery of treatment in brachytherapy. Several accidents, however, have been reported involving high dose-rate brachytherapy system. These events, together with the desire to address the concerns of radiation workers, and the anticipated adoption of the International Basic Safety Standards for Protection Against Ionizing Radiation (IAEA, 1996), led to the development of the radiation safety program at the Department of Radiotherapy, Jose R. Reyes Memorial Medical Center and at the Division of Radiation Oncology, St. Luke's Medical Center. The radiation safety program covers five major aspects: quality control/quality assurance, radiation monitoring, preventive maintenance, administrative measures and quality audit. Measures for evaluation of effectiveness of the program include decreased unnecessary exposures of patients and staff, improved accuracy in treatment delivery and increased department efficiency due to the development of staff vigilance and decreased anxiety. The success in the implementation required the participation and cooperation of all the personnel involved in the procedures and strong management support. This paper will discuss the radiation safety program for a high dose rate brachytherapy facility developed at these two institutes which may serve as a guideline for other hospitals intending to install a similar facility. (author)

  20. The American Brachytherapy Society recommendations for high-dose-rate brachytherapy for head-and-neck carcinoma

    International Nuclear Information System (INIS)

    Nag, Subir; Cano, Elmer R.; Demanes, D. Jeffrey; Puthawala, Ajmel A.; Vikram, Bhadrasain

    2001-01-01

    Purpose: To develop recommendations for use of high-dose-rate (HDR) brachytherapy in patients with head-and-neck cancer. Methods: A panel consisting of members of the American Brachytherapy Society (ABS) performed a literature review, added information based upon their clinical experience, and formulated recommendations for head-and-neck HDR brachytherapy. Results: The ABS recommends the use of brachytherapy as a component of the treatment of head-and-neck tumors. However, the ABS recognizes that some radiation oncologists are reluctant to employ brachytherapy in the head-and-neck region because of the complexity of the postoperative management and concerns about radiation safety. In this regard, HDR eliminates unwanted radiation exposure and thereby permits unrestricted delivery of clinical care to these brachytherapy patients. The ABS made specific recommendations for previously untreated and recurrent head-and-neck cancer patients on patient selection criteria, implant techniques, target volume definition, and HDR treatment parameters (such as time, dose, and fractionation schedules). Suggestions were provided for treatment with HDR alone and in combination with external beam radiation therapy. It should be recognized that only limited experiences exist with HDR brachytherapy in patients with head-and-neck cancers. Therefore, some of these suggested doses have not been extensively tested in clinical practice. Hence, these guidelines will be updated as significant new outcome data are available. Any clinician following these guidelines is expected to use clinical judgment to determine an individual patient's treatment. Conclusions: Little has been published in the clinical literature on HDR brachytherapy in head-and-neck cancer. Based upon the available information and the clinical experience of the panel members, general and site-specific recommendations were offered. Areas for further investigations were identified

  1. Dosimetry Modeling for Focal Low-Dose-Rate Prostate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Al-Qaisieh, Bashar [Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Mason, Josh, E-mail: joshua.mason@nhs.net [Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Bownes, Peter; Henry, Ann [Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Dickinson, Louise [Division of Surgery and Interventional Science, University College London, London (United Kingdom); Department of Radiology, Northwick Park Hospital, London North West NHS Trust, London (United Kingdom); Ahmed, Hashim U. [Division of Surgery and Interventional Science, University College London, London (United Kingdom); University College London Hospital, London (United Kingdom); Emberton, Mark [University College London Hospital, London (United Kingdom); Langley, Stephen [St Luke' s Cancer Centre, Guildford (United Kingdom)

    2015-07-15

    Purpose: Focal brachytherapy targeted to an individual lesion(s) within the prostate may reduce side effects experienced with whole-gland brachytherapy. The outcomes of a consensus meeting on focal prostate brachytherapy were used to investigate optimal dosimetry of focal low-dose-rate (LDR) prostate brachytherapy targeted using multiparametric magnetic resonance imaging (mp-MRI) and transperineal template prostate mapping (TPM) biopsy, including the effects of random and systematic seed displacements and interseed attenuation (ISA). Methods and Materials: Nine patients were selected according to clinical characteristics and concordance of TPM and mp-MRI. Retrospectively, 3 treatment plans were analyzed for each case: whole-gland (WG), hemi-gland (hemi), and ultra-focal (UF) plans, with 145-Gy prescription dose and identical dose constraints for each plan. Plan robustness to seed displacement and ISA were assessed using Monte Carlo simulations. Results: WG plans used a mean 28 needles and 81 seeds, hemi plans used 17 needles and 56 seeds, and UF plans used 12 needles and 25 seeds. Mean D90 (minimum dose received by 90% of the target) and V100 (percentage of the target that receives 100% dose) values were 181.3 Gy and 99.8% for the prostate in WG plans, 195.7 Gy and 97.8% for the hemi-prostate in hemi plans, and 218.3 Gy and 99.8% for the focal target in UF plans. Mean urethra D10 was 205.9 Gy, 191.4 Gy, and 92.4 Gy in WG, hemi, and UF plans, respectively. Mean rectum D2 cm{sup 3} was 107.5 Gy, 77.0 Gy, and 42.7 Gy in WG, hemi, and UF plans, respectively. Focal plans were more sensitive to seed displacement errors: random shifts with a standard deviation of 4 mm reduced mean target D90 by 14.0%, 20.5%, and 32.0% for WG, hemi, and UF plans, respectively. ISA has a similar impact on dose-volume histogram parameters for all plan types. Conclusions: Treatment planning for focal LDR brachytherapy is feasible. Dose constraints are easily met with a notable

  2. High-dose-rate brachytherapy in uterine cervical carcinoma

    International Nuclear Information System (INIS)

    Patel, Firuza D.; Rai, Bhavana; Mallick, Indranil; Sharma, Suresh C.

    2005-01-01

    Purpose: High-dose-rate (HDR) brachytherapy is in wide use for curative treatment of cervical cancer. The American Brachytherapy Society has recommended that the individual fraction size be <7.5 Gy and the range of fractions should be four to eight; however, many fractionation schedules, varying from institution to institution, are in use. We use 9 Gy/fraction of HDR in two to five fractions in patients with carcinoma of the uterine cervix. We found that our results and toxicity were comparable to those reported in the literature and hereby present our experience with this fractionation schedule. Methods and Materials: A total of 121 patients with Stage I-III carcinoma of the uterine cervix were treated with HDR brachytherapy between 1996 and 2000. The total number of patients analyzed was 113. The median patient age was 53 years, and the histopathologic type was squamous cell carcinoma in 93% of patients. The patients were subdivided into Groups 1 and 2. In Group 1, 18 patients with Stage Ib-IIb disease, tumor size <4 cm, and preserved cervical anatomy underwent simultaneous external beam radiotherapy to the pelvis to a dose of 40 Gy in 20 fractions within 4 weeks with central shielding and HDR brachytherapy of 9 Gy/fraction, given weekly, and interdigitated with external beam radiotherapy. The 95 patients in Group 2, who had Stage IIb-IIIb disease underwent external beam radiotherapy to the pelvis to a dose of 46 Gy in 23 fractions within 4.5 weeks followed by two sessions of HDR intracavitary brachytherapy of 9 Gy each given 1 week apart. The follow-up range was 3-7 years (median, 36.4 months). Late toxicity was graded according to the Radiation Therapy Oncology Group criteria. Results: The 5-year actuarial local control and disease-free survival rate was 74.5% and 62.0%, respectively. The actuarial local control rate at 5 years was 100% for Stage I, 80% for Stage II, and 67.2% for Stage III patients. The 5-year actuarial disease-free survival rate was 88.8% for

  3. HIGH-DOSE RATE BRACHYTHERAPY IN CARCINOMA CERVIX STAGE IIIB

    Directory of Open Access Journals (Sweden)

    Sathya Maruthavanan

    2016-07-01

    Full Text Available INTRODUCTION Radiotherapy is the standard treatment in locally advanced (IIB-IVA and early inoperable cases. The current standard of practice with curable intent is concurrent chemoradiation in which intracavitary brachytherapy is an integral component of radiotherapy. This study aims at assessing the efficacy of HDR ICBT (High-dose rate intracavitary brachytherapy in terms local response, normal tissue reactions, and feasibility. METHODS AND MATERIALS A total of 20 patients of stage IIIB cancer of the uterine cervix were enrolled in the study and were planned to receive concurrent chemotherapy weekly along with EBRT (external beam radiotherapy to a dose of 50 Gy/25 Fr. Suitability for ICBT was assessed at 40 Gy/20 Fr. 6/20 patients were suitable at 40 Gy and received HDR ICBT with a dose of 5.5 Gy to point A in 4 sessions (5.5 Gy/4 Fr. The remaining 14/20 patients completed 50 Gy and received HDR ICBT with a dose of 6 Gy to point A in 3 sessions (6 Gy/3 Fr. RESULTS A total of 66 intracavitary applications were done and only one application required dose modification due to high bladder dose, the pelvic control rate was 85% (17/20. 10% (2/20 had stable disease and 5% (1/20 had progressive disease at one year of follow up. When toxicity was considered only 15% developed grade I and grade II rectal complications. Patient compliance and acceptability was 100%. Patients were very comfortable with the short treatment time as compared with patients on LDR ICBT (low-dose rate intracavitary brachytherapy treatment interviewed during the same period. CONCLUSION This study proves that HDR brachytherapy is efficacious and feasible in carcinoma of cervix stage IIIB. It also proves that good dose distribution can be achieved with HDR intracavitary facility by the use of dose optimization. The short treatment time in HDR ICBT makes it possible to maintain this optimised dose distribution throughout the treatment providing a gain in the therapeutic ratio and

  4. The American College of Radiology and the American Brachytherapy Society practice parameter for the performance of radionuclide-based high-dose-rate brachytherapy.

    Science.gov (United States)

    Erickson, Beth A; Bittner, Nathan H J; Chadha, Manjeet; Mourtada, Firas; Demanes, D Jeffrey

    Brachytherapy is a radiation therapy method in which radionuclide sources are used to deliver a radiation dose at a distance of up to a few centimeters by surface, intracavitary, intraluminal, or interstitial application. This practice parameter refers only to the use of radionuclides for brachytherapy. Brachytherapy alone or combined with external beam therapy plays an important role in the management and treatment of patients with cancer. High-dose-rate (HDR) brachytherapy uses radionuclides such as iridium-192 at dose rates of 20 cGy per minute (12 Gy per hour) or more to a designated target point or volume. High-dose-rate (HDR) brachytherapy is indicated for treating malignant or benign tumors where the treatment volume or targeted points are defined and accessible. Copyright © 2016 American Brachytherapy Society and American College of Radiology. Published by Elsevier Inc. All rights reserved.

  5. High dose rate brachytherapy for medically inoperable stage I endometrial cancer

    International Nuclear Information System (INIS)

    Petereit, Daniel G.; Sarkaria, Jann N.; Schink, Julian; Springman, Scott R.; Kinsella, Timothy J.; Buchler, Dolores A.

    1995-01-01

    -operative risk assessment. The three year actuarial survival, disease-free survival and pelvic control rates were 69%, 82% and 86%, respectively. Grade 3 and above chronic complications were encountered in 3 patients. Conclusion: Excellent pelvic control rates were achieved with a 12% ((3(26))) complication rate utilizing HDR brachytherapy for medically inoperable Stage I endometrial cancer. Detailed analysis of significant complications and recurrences confirmed the value of routine ultrasound

  6. Urethral stricture following high dose rate brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Sullivan, Lisa; Williams, Scott G.; Tai, Keen Hun; Foroudi, Farshad; Cleeve, L.; Duchesne, Gillian M.

    2009-01-01

    Purpose: To evaluate the incidence, timing, nature and outcome of urethral strictures following high dose rate brachytherapy (HDRB) for prostate carcinoma. Methods and materials: Data from 474 patients with clinically localised prostate cancer treated with HDRB were analysed. Ninety percent received HDRB as a boost to external beam radiotherapy (HDRBB) and the remainder as monotherapy (HDRBM). Urethral strictures were graded according to the Common Terminology Criteria for Adverse Events v3.0. Results: At a median follow-up of 41 months, 38 patients (8%) were diagnosed with a urethral stricture (6-year actuarial risk 12%). Stricture location was bulbo-membranous (BM) urethra in 92.1%. The overall actuarial rate of grade 2 or more BM urethral stricture was estimated at 10.8% (95% CI 7.0-14.9%), with a median time to diagnosis of 22 months (range 10-68 months). All strictures were initially managed with either dilatation (n = 15) or optical urethrotomy (n = 20). Second line therapy was required in 17 cases (49%), third line in three cases (9%) and 1 patient open urethroplasty (grade 3 toxicity). Predictive factors on multivariate analysis were prior trans-urethral resection of prostate (hazard ratio (HR) 2.81, 95% CI 1.15-6.85, p = 0.023); hypertension (HR 2.83, 95% CI 1.37-5.85, p = 0.005); and dose per fraction used in HDR (HR for 1 Gy increase per fraction 1.33, 95% CI 1.08-1.64, p = 0.008). Conclusions: BM urethral strictures are the most common late grade 2 or more urinary toxicity following HDR brachytherapy for prostate cancer. Most are manageable with minimally invasive procedures. Both clinical and dosimetric factors appear to influence the risk of stricture formation.

  7. Interstitial high-dose-rate brachytherapy in the treatment of base of tongue carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Takacsi-Nagy, Z.; Polgar, C.; Somogyi, A.; Major, T.; Fodor, J.; Nemeth, G. [Dept. of Radiotherapy, National Inst. of Oncology, Budapest (Hungary); Oberna, F. [Dept. of Maxillofacial Surgery, St. Rokus Hospital, Budapest (Hungary); Remenar, E.; Kasler, M. [Dept. of Head and Neck, Maxillofacial and Reconstructive Plastic Surgery, National Inst. of Oncology, Budapest (Hungary)

    2004-12-01

    Background and purpose: to date none of the studies examined the feasibility and efficacy of interstitial high-dose-rate (HDR) brachytherapy in the treatment of carcinoma of the tongue base. Therefore the aim of this study was to contribute to this issue. Patients and methods: between 1992 and 2000 37 patients (mean age 55 years) with T1-4 and NO-3 carcinoma of the base of tongue were presented. Neck dissection was carried out in twelve cases (32%). 30 patients with advanced stage received brachytherapy boost after 50-66.5 Gy (mean, 60 Gy) locoregional external beam irradiation (EBI) and 7 patients with early stage (T1-2, NO) were managed locally with wide tumor excision and sole brachytherapy. 4 of them underwent neck dissection and the others were subjected to 50 Gy regional EBI. The mean dose of boost and sole brachytherapy was 18 Gy and 28 Gy, respectively. Results: the median follow-up time for surviving patients was 51 months. The 7 sole brachytherapy patients are living with no evidence of disease. For patients treated with EBI and brachytherapy boost, the 5-year actuarial rate of local, locoregional recurrence-free and overall survival was 60%, 52% and 46%, respectively. For all patients in univariate analysis larger tumor size (T4 vs. T1-3) was significant negative predictor of local (RR: 7.23) and locoregional control (RR: 3.87), but nodal involvement was not. Delayed soft tissue ulceration and osteoradionecrosis occurred in 4 (13%) EBI and brachytherapy treated patients. None of the sole brachytherapy patients experienced severe late radiation toxicity. Conclusion: EBI combined with interstitial HDR brachytherapy boost result in acceptable local tumor control with low incidence of late side effects in patients with advanced disease. Fractionated sole HDR brachytherapy following tumor excision is a feasible treatment option for patients with early stage cancer and gives excellent local results. (orig.)

  8. Physics and quality assurance for brachytherapy - Part II: Low dose rate and pulsed dose rate

    International Nuclear Information System (INIS)

    Williamson, Jeffrey F.

    1996-01-01

    Purpose: A number of recent developments have revitalized brachytherapy including remote afterloading, implant optimization, increasing use of 3D imaging, and advances in dose specification and basic dosimetry. However, the core physical principles underlying the classical methods of dose calculation and arrangement of multiple sources remain unchanged. The purpose of this course is to review these principles and their applications to low dose-rate interstitial and intracavitary brachytherapy. Emphasis will be placed upon the classical implant systems along with classical and modern methods of dose specification. The level of presentation is designed for radiation oncology residents and beginning clinical physicists. A. Basic Principles (1) Radium-substitute vs. low-energy sealed sources (2) Dose calculation principles (3) The mysteries of source strength specification revealed: mgRaEq, mCi and air-kerma strength B. Interstitial Brachytherapy (1) Target volume, implanted volume, dose specification in implants and implant optimization criteria (2) Classical implant systems: Manchester Quimby and Paris a) Application of the Manchester system to modern brachytherapy b) Comparison of classical systems (3) Permanent interstitial implants a) Photon energy and half life b) Dose specification and pre-operative planning (4) The alphabet soup of dose specification: MCD (mean central dose), minimum dose, MPD (matched peripheral dose), MPD' (minimum peripheral dose) and DVH (dose-volume histogram) quality indices C. Intracavitary Brachytherapy for Carcinoma of the Cervix (1) Basic principles a) Manchester System: historical foundation of U.S. practice patterns b) Principles of applicator design (2) Dose specification and treatment prescription a) mg-hrs, reference points, ICRU Report 38 reference volume --Point A dose vs mg-hrs and IRAK (Integrated Reference Air Kerma) --Tissue volume treated vs mg-hrs and IRAK b) Practical methods of treatment specification and prescription

  9. Physics and quality assurance for brachytherapy - Part II: Low dose rate and pulsed dose rate

    International Nuclear Information System (INIS)

    Williamson, Jeffrey F.

    1997-01-01

    Purpose: A number of recent developments have revitalized brachytherapy including remote afterloading, implant optimization, increasing use of 3D imaging, and advances in dose specification and basic dosimetry. However, the core physical principles underlying the classical methods of dose calculation and arrangement of multiple sources remain unchanged. The purpose of this course is to review these principles and their applications to low dose-rate interstitial and intracavitary brachytherapy. Emphasis will be placed upon the classical implant systems along with classical and modern methods of dose specification. The level of presentation is designed for radiation oncology residents and beginning clinical physicists. A. Basic Principles (1) Radium-substitute vs. low-energy sealed sources (2) Dose calculation principles (3) The mysteries of source strength specification revealed: mgRaEq, mCi and air-kerma strength B. Interstitial Brachytherapy (1) Target volume, implanted volume, dose specification in implants and implant optimization criteria (2) Classical implant systems: Manchester Quimby and Paris a) Application of the Manchester system to modern brachytherapy b) Comparison of classical systems (3) Permanent interstitial implants a) Photon energy and half life b) Dose specification and pre-operative planning (4) The alphabet soup of dose specification: MCD (mean central dose), minimum dose, MPD (matched peripheral dose), MPD' (minimum peripheral dose) and DVH (dose-volume histogram) quality indices C. Intracavitary Brachytherapy for Carcinoma of the Cervix (1) Basic principles a) Manchester System: historical foundation of U.S. practice patterns b) Principles of applicator design (2) Dose specification and treatment prescription a) mg-hrs, reference points, ICRU Report 38 reference volume -- Point A dose vs mg-hrs and IRAK (Integrated Reference Air Kerma) -- Tissue volume treated vs mg-hrs and IRAK b) Practical methods of treatment specification and prescription

  10. Postal auditing methodology used to find out the performance of high rate brachytherapy equipment

    International Nuclear Information System (INIS)

    Morales, J.A.; Campa, R.

    1998-01-01

    This work describes results from a methodology implemented at the Secondary Laboratory for Dosimetric Calibration at CPHR used to check the brachytherapy performance at high doses rate using Cesium 137 or cobalt 60 sources

  11. Verification of the calculation program for brachytherapy planning system of high dose rate (PLATO)

    International Nuclear Information System (INIS)

    Almansa, J.; Alaman, C.; Perez-Alija, J.; Herrero, C.; Real, R. del; Ososrio, J. L.

    2011-01-01

    In our treatments are performed brachytherapy high dose rate since 2007. The procedures performed include gynecological intracavitary treatment and interstitial. The treatments are performed with a source of Ir-192 activity between 5 and 10 Ci such that small variations in treatment times can cause damage to the patient. In addition the Royal Decree 1566/1998 on Quality Criteria in radiotherapy establishes the need to verify the monitor units or treatment time in radiotherapy and brachytherapy. All this justifies the existence of a redundant system for brachytherapy dose calculation that can reveal any abnormality is present.

  12. Reference air kerma rate calibration system for high dose rate Ir-192 brachytherapy sources in Taiwan

    Science.gov (United States)

    Chu, Wei-Han; Yuan, Ming-Chen; Lee, Jeng-Hung; Lin, Yi-Chun

    2017-11-01

    Ir-192 sources are widely used in brachytherapy and the number of treatments is around seven thousand for the use of the high dose rate (HDR) Ir-192 brachytherapy source per year in Taiwan. Due to its physical half-life of 73.8 days, the source should be replaced four times per year to maintain the HDR treatment mode (DDEP, 2005; Coursey et al., 1992). When doing this work, it must perform the source dose trace to assure the dose accuracy. To establish the primary measurement standard of reference air kerma rate(RAKR) for the HDR Ir-192 brachytherapy sources in Taiwan, the Institute of Nuclear Energy Research (INER) fabricated a dual spherical graphite-walled cavity ionization chambers system to directly measure the RAKR of the Ir-192 brachytherapy source. In this system, the ion-charge was accumulated by the two ionization chambers and after correction for the ion recombination, temperature, atmosphere pressure, room scattering, graphite-wall attenuation, air attenuation, source decay, stem effect, and so on. The RAKR of the Ir-192 source was obtained in the ambient conditions of 22 °C and one atmosphere. The measurement uncertainty of the system was around 0.92% in 96% confidence level (k=2.0). To verify the accuracy of the result, the source calibration comparison has been made at the National Radiation Standard Laboratory (NRSL) of INER and Physikalisch-Technische Bundesanstalt (PTB, Germany) in 2015. The ratio of the measurement results between INER and PTB, INER/PTB, was 0.998±0.027 (k=2) which showed good consistency and the performance of the system was verified.

  13. Calculations radiobiological using the quadratic lineal model in the use of the medium dose rate absorbed in brachytherapy. Pt. 3

    International Nuclear Information System (INIS)

    2002-01-01

    Calculations with the quadratic lineal model for medium rate using the equation dose-effect. Several calculations for system of low dose rate brachytherapy plus teletherapy, calculations for brachytherapy with medium dose rate together with teletherapy, dose for fraction and the one numbers of fractions in medium rate

  14. Dose rate correction in medium dose rate brachytherapy for carcinoma cervix

    International Nuclear Information System (INIS)

    Patel, F.D.; Negi, P.S.; Sharma, S.C.; Kapoor, R.; Singh, D.P.; Ghoshal, S.

    1998-01-01

    Purpose: To establish the magnitude of brachytherapy dose reduction required for stage IIB and III carcinoma cervix patients treated by external radiation and medium dose rate (MDR) brachytherapy at a dose rate of 220±10 cGy/h at point A.Materials and methods: In study-I, at the time of MDR brachytherapy application at a dose rate of 220±10 cGy/h at point A, patients received either 3060 cGy, a 12.5% dose reduction (MDR-12.5), or 2450 cGy, a 30% dose reduction (MDR-30), to point A and they were compared to a group of previously treated LDR patients who received 3500 cGy to point A at a dose rate of 55-65 cGy/h. Study-II was a prospective randomized trial and patients received either 2450 cGy, a 30% dose reduction (MDR-II (30)) or 2800 cGy, a 20% dose reduction (MDR-II (20)), at point A. Patients were evaluated for local control of disease and morbidity. Results: In study-I the 5-year actuarial local control rate in the MDR-30 and MDR-12.5 groups was 71.7±10% and 70.5±10%, respectively, compared to 63.4±10% in the LDR group. However, the actuarial morbidity (all grades) in the MDR-12.5 group was 58.5±14% as against 34.9±9% in the LDR group (P 3 developed complication as against 62.5% of those receiving a rectal BED of (140 3 (χ 2 =46.43; P<0.001). Conclusion: We suggest that at a dose rate of 220±10 cGy/h at point A the brachytherapy dose reduction factor should be around 30%, as suggested by radiobiological data, to keep the morbidity as low as possible without compromising the local control rates. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  15. High dose rate endobronchial brachytherapy effectively palliates symptoms due to inoperable lung cancer

    International Nuclear Information System (INIS)

    Celebioglu, B.; Gurkan, O.U.; Savas, I.; Kose, K.; Kurtman, C.; Gonullu, U.; Erdogan, S.

    2002-01-01

    Intraluminal brachytherapy has become an established treatment for major airway occlusion by relapsed or persistent inoperable endobronchial tumors. The aim of this study was to compare the palliation improvement pre- and post-radiotherapy. The study group was 95 patients with the diagnosis of inoperable lung cancer who were eligible for high dose rate (HDR) brachytherapy. Fiber-optic bronchoscopy was performed and the level and degree of endobronchial obstruction were estimated in terms of bronchial obstruction index. Endobronchial irradiation was delivered using remote HDR afterloading brachytherapy with iridium-192. Brachytherapy was delivered at weeks 1, 2 and 3 at 7.5 Gy per fraction or at weeks 1 and 2 at 10 Gy per fraction. All patients were evaluated at the beginning and at the third month of therapy. Using Speiser's symptomatic scoring criteria, the severity of symptoms (dyspnea, cough, hemoptysis and postobstructive pneumonia) was weighted. Bronchoscopic findings at the initial evaluation and at the third month were also scored. Surviving patients were followed up for a minimum of 3 months with a mean of 7.5±5.35 months (median: 6 months). All the symptoms and bronchial obstruction improved significantly after brachytherapy (P 0.05). All the symptoms and bronchial obstruction index seemed to improve after brachytherapy. However, it is difficult to predict the response before the therapy. (author)

  16. Adherence to Vaginal Dilation Following High Dose Rate Brachytherapy for Endometrial Cancer

    International Nuclear Information System (INIS)

    Friedman, Lois C.; Abdallah, Rita; Schluchter, Mark; Panneerselvam, Ashok; Kunos, Charles A.

    2011-01-01

    Purpose: We report demographic, clinical, and psychosocial factors associated with adherence to vaginal dilation and describe the sexual and marital or nonmarital dyadic functioning of women following high dose rate (HDR) brachytherapy for endometrial cancer. Methods and Materials: We retrospectively evaluated women aged 18 years or older in whom early-stage endometrial (IAgr3-IIB) cancers were treated by HDR intravaginal brachytherapy within the past 3.5 years. Women with or without a sexual partner were eligible. Patients completed questionnaires by mail or by telephone assessing demographic and clinical variables, adherence to vaginal dilation, dyadic satisfaction, sexual functioning, and health beliefs. Results: Seventy-eight of 89 (88%) eligible women with early-stage endometrial cancer treated with HDR brachytherapy completed questionnaires. Only 33% of patients were adherers, based on reporting having used a dilator more than two times per week in the first month following radiation. Nonadherers who reported a perceived change in vaginal dimension following radiation reported that their vaginas were subjectively smaller after brachytherapy (p = 0.013). Adherers reported more worry about their sex lives or lack thereof than nonadherers (p = 0.047). Patients reported considerable sexual dysfunction following completion of HDR brachytherapy. Conclusions: Adherence to recommendations for vaginal dilator use following HDR brachytherapy for endometrial cancer is poor. Interventions designed to educate women about dilator use benefit may increase adherence. Although sexual functioning was compromised, it is likely that this existed before having cancer for many women in our study.

  17. Low-Dose-Rate Brachytherapy Versus Cryotherapy in Low- and Intermediate-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gestaut, Matthew M., E-mail: Matthew.Gestaut@BSWHealth.org [Department of Radiation Oncology, Baylor Scott and White Memorial Hospital, Texas A& M University School of Medicine, Temple, Texas (United States); Cai, Wendi [Department of Biostatistics, Baylor Scott and White Health, Temple, Texas (United States); Vyas, Shilpa [Department of Radiation Oncology, Swedish Cancer Institute, Seattle, Washington (United States); Patel, Belur J. [Department of Urology, Baylor Scott and White Memorial Hospital, Texas A& M University School of Medicine, Temple, Texas (United States); Hasan, Salman A. [Department of Radiation Oncology, Baylor Scott and White Memorial Hospital, Texas A& M University School of Medicine, Temple, Texas (United States); MunozMaldonado, Yolanda [Department of Biostatistics, Baylor Scott and White Health, Temple, Texas (United States); Deb, Niloyjyoti; Swanson, Gregory [Department of Radiation Oncology, Baylor Scott and White Memorial Hospital, Texas A& M University School of Medicine, Temple, Texas (United States)

    2017-05-01

    Purpose: Cryotherapy and brachytherapy are definitive local treatment options for low- to intermediate-risk prostate cancer. There are both prospective and retrospective data for brachytherapy, but the use of cryotherapy has been limited primarily to single-institution retrospective studies. Currently, no published evidence has compared low-dose-rate brachytherapy versus cryotherapy. Methods and Materials: Institutional review board approval was obtained to conduct a retrospective chart review of consecutive patients treated at our institution from 1990 to 2012. For inclusion, patients must have received a prostate cancer diagnosis and have been considered to have low- to intermediate-risk disease according to the National Comprehensive Cancer Network criteria. All patients received brachytherapy or cryotherapy treatment. Disease specifics and failure details were collected for all patients. Failure was defined as prostate-specific antigen nadir +2 ng/mL. Results: A total of 359 patients were analyzed. The groups comprised 50 low-risk cryotherapy (LRC), 92 intermediate-risk cryotherapy (IRC), 133 low-risk brachytherapy (LRB), and 84 intermediate-risk brachytherapy (IRB) patients. The median prostate-specific antigen follow-up periods were 85.6 months (LRC), 59.2 months (IRC), 74.9 months (LRB), and 59.8 months (IRB). The 5-year biochemical progression–free survival (bPFS) rate was 57.9% in the cryotherapy group versus 89.6% in the brachytherapy group (P<.0001). The 5-year bPFS rate was 70.0% (LRC), 51.4% (IRC), 89.4% (LRB), and 89.7% (IRB). The bPFS rate was significantly different between brachytherapy and cryotherapy for low- and intermediate-risk groups (P<.05). The mean nadir temperature reached for cryotherapy patients was −35°C (range, −96°C to −6°C). Cryotherapy used a median of 2 freeze-thaw cycles (range, 2-4 freeze-thaw cycles). Conclusions: Results from this study suggest that cryotherapy is inferior to brachytherapy for patients with

  18. Low-Dose-Rate Brachytherapy Versus Cryotherapy in Low- and Intermediate-Risk Prostate Cancer

    International Nuclear Information System (INIS)

    Gestaut, Matthew M.; Cai, Wendi; Vyas, Shilpa; Patel, Belur J.; Hasan, Salman A.; MunozMaldonado, Yolanda; Deb, Niloyjyoti; Swanson, Gregory

    2017-01-01

    Purpose: Cryotherapy and brachytherapy are definitive local treatment options for low- to intermediate-risk prostate cancer. There are both prospective and retrospective data for brachytherapy, but the use of cryotherapy has been limited primarily to single-institution retrospective studies. Currently, no published evidence has compared low-dose-rate brachytherapy versus cryotherapy. Methods and Materials: Institutional review board approval was obtained to conduct a retrospective chart review of consecutive patients treated at our institution from 1990 to 2012. For inclusion, patients must have received a prostate cancer diagnosis and have been considered to have low- to intermediate-risk disease according to the National Comprehensive Cancer Network criteria. All patients received brachytherapy or cryotherapy treatment. Disease specifics and failure details were collected for all patients. Failure was defined as prostate-specific antigen nadir +2 ng/mL. Results: A total of 359 patients were analyzed. The groups comprised 50 low-risk cryotherapy (LRC), 92 intermediate-risk cryotherapy (IRC), 133 low-risk brachytherapy (LRB), and 84 intermediate-risk brachytherapy (IRB) patients. The median prostate-specific antigen follow-up periods were 85.6 months (LRC), 59.2 months (IRC), 74.9 months (LRB), and 59.8 months (IRB). The 5-year biochemical progression–free survival (bPFS) rate was 57.9% in the cryotherapy group versus 89.6% in the brachytherapy group (P<.0001). The 5-year bPFS rate was 70.0% (LRC), 51.4% (IRC), 89.4% (LRB), and 89.7% (IRB). The bPFS rate was significantly different between brachytherapy and cryotherapy for low- and intermediate-risk groups (P<.05). The mean nadir temperature reached for cryotherapy patients was −35°C (range, −96°C to −6°C). Cryotherapy used a median of 2 freeze-thaw cycles (range, 2-4 freeze-thaw cycles). Conclusions: Results from this study suggest that cryotherapy is inferior to brachytherapy for patients with

  19. Brachytherapy - not pulsed and low rate brachytherapy. Medical radiation protection - ED 4248

    International Nuclear Information System (INIS)

    2008-06-01

    After an indication of authorizations required to perform brachytherapy, this sheet indicates the concerned personnel, indicates the different treatment steps, briefly describes the risk related to ionizing radiations, indicates the various aspects of risk assessment and of determination of exposure levels (definition of controlled and monitored areas, personnel classification, possible methods for dose monitoring), presents the strategy for risk management (rules regarding risk reduction, technical measures regarding the installation, individual technical measures, training and information, prevention and medical monitoring) and how this risk management can be assessed

  20. High-dose-rate brachytherapy for uterine cervical cancer: the results of different fractionation regimen

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Won Sup; Kim, Tae Hyun; Yang, Dae Sik; Choi, Myung Sun; Kim, Chul Yong [College of Medicine, Korea University, Seoul (Korea, Republic of)

    2002-09-15

    Although high-dose-rate (HDR) brachytherapy regimens have been practiced with a variety of modalities and various degrees of success, few studies on the subject have been conducted. The purpose of this study was to compare the results of local control and late complication rate according to different HDR brachytherapy fractionation regimens in uterine cervical cancer patients. From November 1992 to March 1998, 224 patients with uterine cervical cancer were treated with external beam irradiation and HDR brachytherapy. In external pelvic radiation therapy, the radiation dose was 45 {approx} 54 Gy (median dose 54 Gy) with daily fraction size 1.8 Gy, five times per week. In HDR brachytherapy, 122 patients (Group A) were treated with three times weekly with 3 Gy to line-A (isodose line of 2 cm radius from source) and 102 patients (Group B) underwent the HDR brachytherapy twice weekly with 4 or 4.5 Gy to line-A after external beam irradiation. Iridium-192 was used as the source of HDR brachytherapy. Late complication was assessed from grade 1 to 5 using the RTOG morbidity grading system. The local control rate (LCR) at 5 years was 80% in group A and 84% in group B ({rho} = 0.4523). In the patients treated with radiation therapy alone, LCR at 5 years was 60.9% in group A and 76.9% in group B ({rho} = 0.2557). In post-operative radiation therapy patients, LCR at 5 years was 92.6% in group A and 91.6% in group B ({rho} 0.8867). The incidence of late complication was 18% (22 patients) and 29.4% (30 patients), of bladder complication was 9.8% (12 patients) and 14.7% (15 patients), and of rectal complication was 9.8% (12 patients) and 21.6% (22 patients), in group A and B, respectively. Lower fraction sized HDR brachytherapy was associated with decrease in late complication ({rho} =0.0405) (rectal complication, {rho} = 0.0147; bladder complication, {rho} =0.115). The same result was observed in postoperative radiation therapy patients ({rho} = 0.0860) and radiation only

  1. National Utility Rate Database: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Ong, S.; McKeel, R.

    2012-08-01

    When modeling solar energy technologies and other distributed energy systems, using high-quality expansive electricity rates is essential. The National Renewable Energy Laboratory (NREL) developed a utility rate platform for entering, storing, updating, and accessing a large collection of utility rates from around the United States. This utility rate platform lives on the Open Energy Information (OpenEI) website, OpenEI.org, allowing the data to be programmatically accessed from a web browser, using an application programming interface (API). The semantic-based utility rate platform currently has record of 1,885 utility rates and covers over 85% of the electricity consumption in the United States.

  2. Accelerated interstitial high dose rate brachytherapy as a boost technique in the treatment of soft tissue sarcomas

    International Nuclear Information System (INIS)

    Hixson, William C.; Raben, David; Jaffe, Kenneth A.; Salter, Merle M.

    1996-01-01

    Purpose/Objective: The efficacy of low dose rate (LDR) interstitial brachytherapy has clearly been established in the treatment of high grade soft tissue sarcomas. Our objective is to report the utility, technical considerations, and potential advantages of employing interstitial HDR brachytherapy as an adjuvant boost treatment for soft tissue sarcomas. Materials and Methods: Seventeen soft tissue sarcomas received HDR brachytherapy from 1990-1994. Two patients without follow-up were excluded. Sites of primary disease included the following: thigh (n=6), gluteal region (n=3), upper extremity (n=3), popliteal fossa (n=1), axilla (n=1), and chest wall (n=1). Ten of 15 lesions were grade II-III. Resection margins were negative (n=7), microscopically positive (n=7), or grossly positive (n=1). In 11 patients with previously untreated disease, postoperative HDR brachytherapy was delivered as adjuvant treatment in combination with either preoperative (n=5) or postoperative (n=6) external beam radiation therapy. Furthermore, 4 patients who had been previously irradiated and experienced recurrence underwent reresection followed by HDR brachytherapy boost; one of these patients also received additional postoperative external beam radiation therapy. In general, a delay of 2 - 3 weeks was allowed between preoperative external radiation therapy and surgery. A similar delay was employed between HDR brachytherapy and subsequent postoperative external radiation therapy. Median external beam radiation dose was 50.0 Gy, range 30.6 - 50.4 Gy. At the time of resection, blind end HDR catheters were implanted in a single plane in the tumor bed, spaced 1 cm apart, as defined by the surgical clips. The catheters were placed so as to extend 2 cm past the surgical clips in the cranio-caudad direction and 1 cm in the medial-lateral direction and stabilized with absorbable sutures. After allowing for five days of wound healing, BID brachytherapy (minimum inter-fraction interval 6 hours) was

  3. Inverse planning in brachytherapy from radium to high rate 192 iridium afterloading

    International Nuclear Information System (INIS)

    Lahanas, M.; Mould, R.F.; Baltas, D.; Karauzakis, K.; Giannouli, S.; Baltas, D.

    2004-01-01

    We consider the inverse planning problem in brachytherapy, i.e. the problem to determine an optimal number of catheters, number of sources for low-dose rate brachytherapy (LDR) and the optimal dwell times for high-dose rate brachytherapy (HDR) necessary to obtain an optimal as possible dose distribution. Starting from the 1930s, inverse planning for LDR brachytherapy used geometrically derived rules to determine the optimal placement of sources in order to achieve a uniform dose distribution of a specific level in planes, spheres and cylinders. Rules and nomograms were derived which still are widely used. With the rapid development of 3D imaging technologies and the rapidly increasing computer power we have now entered the new era of computer-based inverse planning in brachytherapy. The inverse planning is now an optimisation process adapted to the individual geometry of the patient. New inverse planning optimisation algorithms are anatomy-based that consider the real anatomy of the tumour and the organs at risk (OAR). Computer-based inverse planning considers various effects such as stability of solutions for seed misplacements which cannot ever be solved analytically without gross simplifications. In the last few years multiobjective (MO) inverse planning algorithms have been developed which recognise the MO optimisation problem which is inherent in inverse planning in brachytherapy. Previous methods used a trial and error method to obtain a satisfactory solution. MO optimisation replaces this trial and error process by presenting a representative set of dose distributions that can be obtained. With MO optimisation it is possible to obtain information that can be used to obtain the optimum number of catheters, their position and the optimum distribution of dwell times for HDR brachytherapy. For LDR brachytherapy also the stability of solutions due to seed migration can also be improved. A spectrum of alternative solutions is available and the treatment planner

  4. High-dose-rate interstitial brachytherapy for the treatment of penile carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Petera, J.; Odrazka, K.; Zouhar, M.; Bedrosova, J.; Dolezel, M. [Dept. of Oncology and Radiotherapy, Charles Univ. Medical School and Teaching Hospital, Hradec Kralove (Czech Republic)

    2004-02-01

    Background: interstitial low-dose-rate (LDR) brachytherapy allows conservative treatment of T1-T2 penile carcinoma. High-dose-rate (HDR) is often considered to be dangerous for interstitial implants because of a higher risk of complications, but numerous reports suggest that results may be comparable to LDR. Nevertheless, there are no data in the literature available regarding HDR interstitial brachytherapy for carcinoma of the penis. Case report: a 64-year-old man with T1 NO MO epidermoid carcinoma of the glans is reported. Interstitial HDR brachytherapy was performed using the stainless hollow needle technique and a breast template for fixation and good geometry. The dose delivered was 18 x 3 Gy twice daily. Results: after 232 days from brachytherapy, the patient was without any evidence of the tumor, experienced no serious radiation-induced complications, and had a fully functional organ. Conclusion: HDR interstitial brachytherapy is feasible in selected case of penis carcinoma, when careful planning and small single fractions are used. (orig.)

  5. Salvage high-dose-rate brachytherapy for local prostate cancer recurrence after radical radiotherapy

    Directory of Open Access Journals (Sweden)

    V. A. Solodkiy

    2016-01-01

    Full Text Available Studies salvage interstitial radiation therapy for recurrent prostate cancer, launched at the end of the XX century. In recent years, more and more attention is paid to high-dose-rate brachytherapy (HDR-BT as a method of treating local recurrence.The purpose of research – preliminary clinical results of salvage high-dose-rate brachytherapy applied in cases of suspected local recurrence or of residual tumour after radiotherapy.Preliminary findings indicate the possibility of using HDR-BT, achieving local tumor control with low genitourinary toxicity.

  6. Local vaginal anesthesia during high-dose-rate intracavitary brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Chen, H.-C.; Wan Leung, Stephen; Wang, C.-J.; Sun, L.-M.; Fang, F.-M.; Huang, E.-Y.; Wang, S.-J.; Yang, C.-W.

    1998-01-01

    Purpose: To evaluate the clinical efficacy of local vaginal lidocaine application for pain relief during high-dose-rate (HDR) intracavitary brachytherapy for patients with cervical cancer, and to investigate sequential changes in serum levels of lidocaine during the procedures. Methods and Materials: This prospective study was designed to examine the analgesic effect, physical response, and side effects of local anesthesia during HDR intracavitary brachytherapy. Forty patients were enrolled. All patients received 10-15 MV X-rays to the pelvis with a total dose of 45-59.4 Gy 5-6 weeks before undergoing HDR intracavitary brachytherapy. All patients underwent first intracavitary brachytherapy under general anesthesia. These patients were randomly allocated to receive one of two different treatment protocols as follows: (1) treatment session - control session - treatment session - control session; or (2) control session - treatment session- control session - treatment session. In the treatment sessions, topical anesthesia was administered using 4 ml of 10% lidocaine solution sprayed liberally on the cervix and vagina during intracavitary brachytherapy. In the control sessions, a placebo was administered in the same manner during brachytherapy. The Hensche's applicators for brachytherapy were inserted into the cervix and vagina 5 min after lidocaine application. The visual analogue scale (VAS) was used to assess pain and discomfort during brachytherapy. Blood pressure and heart rates were measured to evaluate the physiological response. Another prospective study was then performed to investigate the sequential changes of serum lidocaine levels during the anesthetic procedure. Eleven additional patients with similar disease state and demographic characteristics were enrolled and blood samples were obtained before, and 5, 15, 30, and 45 min after the initiation of lidocaine application. Results: The mean VAS values recorded during the treatment sessions and control

  7. Low-Dose-Rate Brachytherapy Versus Cryotherapy in Low- and Intermediate-Risk Prostate Cancer.

    Science.gov (United States)

    Gestaut, Matthew M; Cai, Wendi; Vyas, Shilpa; Patel, Belur J; Hasan, Salman A; MunozMaldonado, Yolanda; Deb, Niloyjyoti; Swanson, Gregory

    2017-05-01

    Cryotherapy and brachytherapy are definitive local treatment options for low- to intermediate-risk prostate cancer. There are both prospective and retrospective data for brachytherapy, but the use of cryotherapy has been limited primarily to single-institution retrospective studies. Currently, no published evidence has compared low-dose-rate brachytherapy versus cryotherapy. Institutional review board approval was obtained to conduct a retrospective chart review of consecutive patients treated at our institution from 1990 to 2012. For inclusion, patients must have received a prostate cancer diagnosis and have been considered to have low- to intermediate-risk disease according to the National Comprehensive Cancer Network criteria. All patients received brachytherapy or cryotherapy treatment. Disease specifics and failure details were collected for all patients. Failure was defined as prostate-specific antigen nadir +2 ng/mL. A total of 359 patients were analyzed. The groups comprised 50 low-risk cryotherapy (LRC), 92 intermediate-risk cryotherapy (IRC), 133 low-risk brachytherapy (LRB), and 84 intermediate-risk brachytherapy (IRB) patients. The median prostate-specific antigen follow-up periods were 85.6 months (LRC), 59.2 months (IRC), 74.9 months (LRB), and 59.8 months (IRB). The 5-year biochemical progression-free survival (bPFS) rate was 57.9% in the cryotherapy group versus 89.6% in the brachytherapy group (Pcryotherapy for low- and intermediate-risk groups (Pcryotherapy patients was -35°C (range, -96°C to -6°C). Cryotherapy used a median of 2 freeze-thaw cycles (range, 2-4 freeze-thaw cycles). Results from this study suggest that cryotherapy is inferior to brachytherapy for patients with low- to intermediate-risk prostate cancer. Patient selection criteria for consideration of cryotherapy and brachytherapy are similar in terms of anesthesia candidacy. Therefore, cryotherapy would not be recommended as a first-line local therapy for this particular

  8. Monte Carlo dose calculations for high-dose-rate brachytherapy using GPU-accelerated processing.

    Science.gov (United States)

    Tian, Z; Zhang, M; Hrycushko, B; Albuquerque, K; Jiang, S B; Jia, X

    2016-01-01

    Current clinical brachytherapy dose calculations are typically based on the Association of American Physicists in Medicine Task Group report 43 (TG-43) guidelines, which approximate patient geometry as an infinitely large water phantom. This ignores patient and applicator geometries and heterogeneities, causing dosimetric errors. Although Monte Carlo (MC) dose calculation is commonly recognized as the most accurate method, its associated long computational time is a major bottleneck for routine clinical applications. This article presents our recent developments of a fast MC dose calculation package for high-dose-rate (HDR) brachytherapy, gBMC, built on a graphics processing unit (GPU) platform. gBMC-simulated photon transport in voxelized geometry with physics in (192)Ir HDR brachytherapy energy range considered. A phase-space file was used as a source model. GPU-based parallel computation was used to simultaneously transport multiple photons, one on a GPU thread. We validated gBMC by comparing the dose calculation results in water with that computed TG-43. We also studied heterogeneous phantom cases and a patient case and compared gBMC results with Acuros BV results. Radial dose function in water calculated by gBMC showed GPU-based MC dose calculation package, gBMC, for HDR brachytherapy make it attractive for clinical applications. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  9. Interstitial high-dose rate brachytherapy as boost for anal canal cancer

    International Nuclear Information System (INIS)

    Falk, Alexander Tuan; Claren, Audrey; Benezery, Karen; François, Eric; Gautier, Mathieu; Gerard, Jean-Pierre; Hannoun-Levi, Jean-Michel

    2014-01-01

    To assess clinical outcomes of patients treated with a high-dose rate brachytherapy boost for anal canal cancer (ACC). From August 2005 to February 2013, 28 patients presenting an ACC treated by split-course external beam radiotherapy (EBRT) and HDR brachytherapy with or without chemotherapy in a French regional cancer center in Nice were retrospectively analyzed. Median age was 60.6 years [34 – 83], 25 patients presented a squamous cell carcinoma and 3 an adenocarcinoma; 21 received chemotherapy. Median dose of EBRT was 45 Gy [43.2 – 52]. Median dose of HDR brachytherapy was 12 Gy [10 - 15] with a median duration of 2 days. Median overall treatment time was 63 days and median delay between EBRT and brachytherapy was 20 days. Two-year local relapse free, metastatic free, disease free and overall survivals were 83%, 81.9%, 71.8% and 87.7% respectively. Acute toxicities were frequent but not severe with mostly grade 1 toxicities: 37% of genito-urinary, 40.7% of gastro-intestinal and 3.7% of cutaneous toxicities. Late toxicities were mainly G1 (43.1%) and G2 (22%). Two-year colostomy-free survival was 75.1%, one patient had a definitive sphincter amputation. High-dose rate brachytherapy for anal canal carcinoma as boost represents a feasible technique compared to low or pulsed-dose rate brachytherapy. This technique remains an excellent approach to precisely boost the tumor in reducing the overall treatment time

  10. High dose rate versus low dose rate brachytherapy for oral cancer--a meta-analysis of clinical trials.

    Science.gov (United States)

    Liu, Zhenxing; Huang, Shengyun; Zhang, Dongsheng

    2013-01-01

    To compare the efficacy and safety of high dose rate (HDR) and low dose rate (LDR) brachytherapy in treating early-stage oral cancer. A systematic search of MEDLINE, EMBASE and Cochrane Library databases, restricted to English language up to June 1, 2012, was performed to identify potentially relevant studies. Only randomized controlled trials (RCT) and controlled trials that compared HDR to LDR brachytherapy in treatment of early-stage oral cancer (stages I, II and III) were of interest. Two investigators independently extracted data from retrieved studies and controversies were solved by discussion. Meta-analysis was performed using RevMan 5.1. One RCT and five controlled trials (607 patients: 447 for LDR and 160 for HDR) met the inclusion criteria. The odds ratio showed no statistically significant difference between LDR group and HDR group in terms of local recurrence (OR = 1.12, CI 95% 0.62-2.01), overall mortality (OR = 1.01, CI 95% 0.61-1.66) and Grade 3/4 complications (OR = 0.86, CI 95% 0.52-1.42). This meta-analysis indicated that HDR brachytherapy was a comparable alternative to LDR brachytherapy in treatment of oral cancer. HDR brachytherapy might become a routine choice for early-stage oral cancer in the future.

  11. High dose-rate brachytherapy source position quality assurance using radiochromic film

    International Nuclear Information System (INIS)

    Evans, M.D.C.; Devic, S.; Podgorsak, E.B.

    2007-01-01

    Traditionally, radiographic film has been used to verify high-dose-rate brachytherapy source position accuracy by co-registering autoradiographic and diagnostic images of the associated applicator. Filmless PACS-based clinics that do not have access to radiographic film and wet developers may have trouble performing this quality assurance test in a simple and practical manner. We describe an alternative method for quality assurance using radiochromic-type film. In addition to being easy and practical to use, radiochromic film has some advantages in comparison with traditional radiographic film when used for HDR brachytherapy quality assurance

  12. Clinical results of iridium-192 high dose rate brachytherapy with external beam radiotherapy

    International Nuclear Information System (INIS)

    Nohara, Takahiro; Mizokami, Atsushi; Kumano, Tomoyasu

    2010-01-01

    Here, we report the clinical results of iridium-192 high dose rate brachytherapy at Kanazawa University Hospital. The study population consisted of 166 patients diagnosed with T1c-T3bN0M0 prostate cancer treated with high dose rate brachytherapy and external beam radiotherapy and followed up for 6 months or longer. Treatment consisted of external beam radiotherapy to the prostate at 44 Gy/22 fractions and high dose rate brachytherapy at 18 Gy/3 fractions. Median follow-up interval was 31.5 months (range 6.2-88.7). The overall 5-year biological recurrence-free survival rate was 93.0%. The 5-year biological recurrence-free survival rates for the patients in low-, intermediate- and high-risk groups according to the D'Amico risk classification criteria were 96.1%, 89.0% and 91.6%, respectively. When limited to the group that did not receive adjuvant hormonal therapy, the 5-year biological recurrence-free survival rates for the patients in low-, intermediate- and high-risk groups were 96.0%, 96.3% and 82.9%, respectively. Grade 3 or greater adverse effects were rare. Urethral stricture was observed in only 1.0% of the patients. Eighty percent of patients retained erectile function after high dose rate brachytherapy and reported satisfaction with sexual function. High dose rate brachytherapy is considered a good form of treatment for localized prostate cancer, although longer follow-up is necessary. (author)

  13. Modelling second malignancy risks from low dose rate and high dose rate brachytherapy as monotherapy for localised prostate cancer.

    Science.gov (United States)

    Murray, Louise; Mason, Joshua; Henry, Ann M; Hoskin, Peter; Siebert, Frank-Andre; Venselaar, Jack; Bownes, Peter

    2016-08-01

    To estimate the risks of radiation-induced rectal and bladder cancers following low dose rate (LDR) and high dose rate (HDR) brachytherapy as monotherapy for localised prostate cancer and compare to external beam radiotherapy techniques. LDR and HDR brachytherapy monotherapy plans were generated for three prostate CT datasets. Second cancer risks were assessed using Schneider's concept of organ equivalent dose. LDR risks were assessed according to a mechanistic model and a bell-shaped model. HDR risks were assessed according to a bell-shaped model. Relative risks and excess absolute risks were estimated and compared to external beam techniques. Excess absolute risks of second rectal or bladder cancer were low for both LDR (irrespective of the model used for calculation) and HDR techniques. Average excess absolute risks of rectal cancer for LDR brachytherapy according to the mechanistic model were 0.71 per 10,000 person-years (PY) and 0.84 per 10,000 PY respectively, and according to the bell-shaped model, were 0.47 and 0.78 per 10,000 PY respectively. For HDR, the average excess absolute risks for second rectal and bladder cancers were 0.74 and 1.62 per 10,000 PY respectively. The absolute differences between techniques were very low and clinically irrelevant. Compared to external beam prostate radiotherapy techniques, LDR and HDR brachytherapy resulted in the lowest risks of second rectal and bladder cancer. This study shows both LDR and HDR brachytherapy monotherapy result in low estimated risks of radiation-induced rectal and bladder cancer. LDR resulted in lower bladder cancer risks than HDR, and lower or similar risks of rectal cancer. In absolute terms these differences between techniques were very small. Compared to external beam techniques, second rectal and bladder cancer risks were lowest for brachytherapy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Evaluation of performance and quality control of high dose rate Ir-192 remote afterloading brachytherapy equipment

    International Nuclear Information System (INIS)

    Ahmed, M. A. M.

    2005-09-01

    Brachytherapy is the use of encapsulated radioactive sources to deliver a radiation dose at a short distance over a short time for treatment of malignant tumors. In Sudan, mainly in Radiation and Isotopes Center Khartoum (RICK) brachytherapy was introduced in 1989 using manual afterloading low dose rate 137 Cs for treatment of carcinoma of the cervix, but for safety reasons now it replace by high dose rate 192 Ir afterloading system (HDR) with remotely controlled device to deliver controlled radiation dose for treatment of carcinoma of cervix, esophagus and nasopharynx. This study was carried out in high dose rate 192 Ir afterloading brachytherapy equipment (Gamma Med 12i unit) located at RICK to evaluate the performance and to perform comprehensive quality control of the treatment unit with respect to three poles: safety systems, physical parameters and calibration of Ir-192 source through some quality control checks, so as to ensure that the equipment meets the safety standard. The study shows that all the safety systems which include the mechanical checks are work properly, the average of the dose rate measured at different positions from the treatment unit which represent the leakage radiation by using RDS-120 universal survey meter is less than 10μSv/h. The physical parameters which include the check of a source position accuracy by using x-OMAT ready pack film and catheter guide tube is I mm. The source strength that was obtained from the calibration procedures following the IAEA-TECDOC 1274 protocol by using HDR 1000 plus well type ionization chamber is different from the value of International Standard Laboratory by 1.5%. It was found that the brachytherapy equipment and the source used in brachytherapy meets the users requirements except some necessary requirements, so some recommendations was putted include these requirements.(Author)

  15. Sci-Thur PM – Brachytherapy 06: 3D Printed Surface Applicators for High Dose Rate Brachytherapy

    International Nuclear Information System (INIS)

    Clarke, Scott; Yewondwossen, Mammo; Robar, James

    2016-01-01

    Purpose: The purpose of this work is to develop a new applicator for administering high dose rate (HDR) brachytherapy using 3D printing technology. Primary advantages of using a 3D printed applicator will be to offer a more streamlined approach for therapists and patients while achieving better conformity, reproducibility, and patient specific applicators. Methods: A phantom study was conducted to measure the effectiveness of a 3D printed surface applicator by analyzing tumours on three locations of the body: the foot, nose, and scalp. The applicator was designed using Eclipse and further modified using Blender to create the catheter tunnels before being printed on a Lulzbot Taz 5 3D printer. A radiation plan was made using Oncentra Brachytherapy for a control treatment option using Freiburg Flaps and one with the novel method of a 3D printed applicator. A comparative analysis was made using D90, D100, V100, V150, and V200 Results: The 3D printed applicator showed comparable dose coverage with significant improvements on highly irregular surfaces when analyzed against a plan made using Freiburg Flaps. Although both plans exhibited complete tumour coverage, the 3D applicator showed improvements in D90 and V150 and the 3D applicator had a dose homogeneity index (DHI) of 0.99 compared to a DHI of 0.97 for the control. Therapist prep time also dropped significantly due to the lack of need for a thermoplastic mesh. Conclusions: 3D printed applicators for treatment of superficial sites proved to offer more patient convenience, less prep time, better conformity and tighter margins.

  16. Current situation of high-dose-rate brachytherapy for cervical cancer in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rogerio Matias Vidal da; Souza, Divanizia do Nascimento, E-mail: rmv.fisica@gmail.com [Universidade Federal de Sergipe (UFS), Sao Cristovao, SE (Brazil); Pinezi, Juliana Castro Dourado [Pontificia Universidade Catolica de Goias (PUC-Goias), Goiania, GO (Brazil); Macedo, Luiz Eduardo Andrade [Hospital Chama, Arapiraca, AL (Brazil)

    2014-05-15

    To assess the current situation of high-dose-rate (HDR) brachytherapy for cancer of the cervix in Brazil, regarding apparatuses, planning methods, prescription, fractionation schedule and evaluation of dose in organs at risk. Materials and methods: in the period between March/2012 and May/2013, a multiple choice questionnaire was developed and sent to 89 Brazilian hospitals which perform HDR brachytherapy. Results: sixty-one services answered the questionnaire. All regions of the country experienced a sharp increase in the number of HDR brachytherapy services in the period from 2001 to 2013. As regards planning, although a three-dimensional planning software was available in 91% of the centers, conventional radiography was mentioned by 92% of the respondents as their routine imaging method for such a purpose. Approximately 35% of respondents said that brachytherapy sessions are performed after teletherapy. The scheme of four 7 Gy intracavitary insertions was mentioned as the most frequently practiced. Conclusion: the authors observed that professionals have difficulty accessing adjuvant three-dimensional planning tools such as computed tomography and magnetic resonance imaging. (author)

  17. Novel Use of the Contura for High Dose Rate Cranial Brachytherapy

    International Nuclear Information System (INIS)

    Scanderbeg, Daniel J.; Alksne, John F.; Lawson, Joshua D.; Murphy, Kevin T.

    2011-01-01

    A popular choice for treatment of recurrent gliomas was cranial brachytherapy using the GliaSite Radiation Therapy System. However, this device was taken off the market in late 2008, thus leaving a treatment void. This case study presents our experience treating a cranial lesion for the first time using a Contura multilumen, high-dose-rate (HDR) brachytherapy balloon applicator. The patient was a 47-year-old male who was diagnosed with a recurrent right frontal anaplastic oligodendroglioma. Previous radiosurgery made him a good candidate for brachytherapy. An intracavitary HDR balloon brachytherapy device (Contura) was placed in the resection cavity and treated with a single fraction of 20 Gy. The implant, treatment, and removal of the device were all completed without incident. Dosimetry of the device was excellent because the dose conformed very well to the target. V90, V100, V150, and V200 were 98.9%, 95.7%, 27.2, and 8.8 cc, respectively. This patient was treated successfully using the Contura multilumen balloon. Contura was originally designed for deployment in a postlumpectomy breast for treatment by accelerated partial breast irradiation. Being an intracavitary balloon device, its similarity to the GliaSite system makes it a viable replacement candidate. Multiple lumens in the device also make it possible to shape the dose delivered to the target, something not possible before with the GliaSite applicator.

  18. Determination of the tissue inhomogeneity correction in high dose rate Brachytherapy for Iridium-192 source

    Directory of Open Access Journals (Sweden)

    Barlanka Ravikumar

    2012-01-01

    Full Text Available In Brachytherapy treatment planning, the effects of tissue heterogeneities are commonly neglected due to lack of accurate, general and fast three-dimensional (3D dose-computational algorithms. In performing dose calculations, it is assumed that the tumor and surrounding tissues constitute a uniform, homogeneous medium equivalent to water. In the recent past, three-dimensional computed tomography (3D-CT based treatment planning for Brachytherapy applications has been popularly adopted. However, most of the current commercially available planning systems do not provide the heterogeneity corrections for Brachytherapy dosimetry. In the present study, we have measured and quantified the impact of inhomogeneity caused by different tissues with a 0.015 cc ion chamber. Measurements were carried out in wax phantom which was employed to measure the heterogeneity. Iridium-192 (192 Ir source from high dose rate (HDR Brachytherapy machine was used as the radiation source. The reduction of dose due to tissue inhomogeneity was measured as the ratio of dose measured with different types of inhomogeneity (bone, spleen, liver, muscle and lung to dose measured with homogeneous medium for different distances. It was observed that different tissues attenuate differently, with bone tissue showing maximum attenuation value and lung tissue resulting minimum value and rest of the tissues giving values lying in between those of bone and lung. It was also found that inhomogeneity at short distance is considerably more than that at larger distances.

  19. Gynecological brachytherapy - from low-dose-rate to high-tech. Gynaekologische Brachytherapie - von Low-dose-rate zu High-tech

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, T. (Abt. Strahlenthgerapie, Klinik und Poliklinik fuer Radiologie, Medizinische Akademie ' Carl Gustav Carus' , Dresden (Germany)); Christen, N. (Abt. Strahlenthgerapie, Klinik und Poliklinik fuer Radiologie, Medizinische Akademie ' Carl Gustav Carus' , Dresden (Germany)); Alheit, H.D. (Abt. Strahlenthgerapie, Klinik und Poliklinik fuer Radiologie, Medizinische Akademie ' Carl Gustav Carus' , Dresden (Germany))

    1993-03-01

    The transition from low-dose-rate (LDR) brachytherapy to high-dose-rate (HDR) afterloading treatment is in progress in most centres of radiation therapy. First reports of studies comparing HDR and LDR treatment in cervix cancer demonstrate nearly equal local control. In our own investigations on 319 patients with primary irradiated carcinoma of the cervix (125 HDR/194 LDR) we found the following control rates: Stage FIGO I 95.4%/82.9% (HDR versus LDR), stage FIGO II 71.4%/73.7%, stage FIGO III 57.9%/38.5%. The results are not significant. The side effects - scored after EORT/RTOG criteria - showed no significant differences between both therapies for serious radiogenic late effects on intestine, bladder and vagina. The study and findings from the literature confirm the advantage of the HDR-procedure for patient and radiooncologist and for radiation protection showing at least the same results as in the LDR-area. As for radiobiolgical point of view it is important to consider that the use of fractionation in the HDR-treatment is essential for the sparing of normal tissues and therefore a greater number of small fractionation doses in the brachytherapy should be desirable too. On the other hand the rules, which are true for fractionated percutaneous irradiation therapy (overall treatment time as short as possible to avoid reppopulation of tumor cells) should be taken into consideration in combined brachy-teletherapy regime in gynecologic tumors. The first step in this direction may be accelerated regime with a daily application of both treatment procedures. The central blocking of the brachytherapy region from the whole percutaneous treatment target volume should be critically reflected, especially in the case of advanced tumors. (orig.)

  20. Evaluation of functioning of high dose rate brachytherapy at the Instituto Nacional do Cancer

    International Nuclear Information System (INIS)

    Guedes, Laura M.A.; Barreto, Rodrigo V.; Silva, Penha M.; Macedo, Afranio A.; Borges, Solange C.; Martinez, Valeria P.O.

    2001-01-01

    Quality control tests are very useful tools to assure the quality of patient's treatment. A daily control of the high dose rate micro selectron was performed based on the security parameters of the equipment and on the quickness of performance. The purpose of this report is to evaluate and to discuss the errors found during the first three years with the high dose rate brachytherapy, at the Instituto Nacional de Cancer. (author)

  1. The Preliminary Prototype of Medium Dose Rate Brachytherapy Equipment

    International Nuclear Information System (INIS)

    A- Satmoko; T- Harjanto; IM- Putra; Kristiyanti

    2013-01-01

    A preliminary prototype of a brachytherapy equipment has been constructed. The work started by developing conceptual design, followed by basic design and detailed design. In the conceptual design, design requirements are stated. In the basic design, technical specifications for main components are determined. In detailed design, general drawings are discussed. The prototype consists of three main systems: a mechanical system, an instrumentation system, and a safety system. The mechanical system assures the movement mechanism of the isotope source position beginning from the standby position until the applicators. It consists of three main modules: a position handling module, a container module, and a channel distribution module. The position handling module serves to move the isotope source position. As shielding, the second module is to store the source when the equipment is in standby position. The prototype provides 12 output channels. The channel selection is performed by the third module. The instrumentation system controls the movement of source position by handling motor operations. It consists of several modules. A micro controller module serves as a control center whose task includes both controlling motors and communicating with computer. A motor module serves to handle motors. 10 sensors, including their signal conditionings, are introduced to read the environment conditions of the equipment. LED's are used to display these conditions. In order to facilitate the operators’ duty, communication via RS232 is provided. The brachytherapy equipment can therefore be operated by using computer. Interface software is developed using C# language. To complete both mechanical and instrumentation systems performance, a safety system is developed to make sure that the safety for operator and patients from receiving excessive radiation. An interlock system is introduced to guard against abnormal conditions. In the worst case, a manual intervention by the operator is

  2. The Preliminary Prototype of Medium Dose Rate Brachytherapy Equipment

    Directory of Open Access Journals (Sweden)

    A. Satmoko

    2013-08-01

    Full Text Available A preliminary prototype of a brachytherapy equipment has been constructed. The work started by developing conceptual design, followed by basic design and detailed design. In the conceptual design, design requirements are stated. In the basic design, technical specifications for main components are determined. In detailed design, general drawings are discussed. The prototype consists of three main systems: a mechanical system, an instrumentation system, and a safety system. The mechanical system assures the movement mechanism of the isotope source position beginning from the standby position until the applicators. It consists of three main modules: a position handling module, a container module, and a channel distribution module. The position handling module serves to move the isotope source position. As shielding, the second module is to store the source when the equipment is in standby position. The prototype provides 12 output channels. The channel selection is performed by the third module. The instrumentation system controls the movement of source position by handling motor operations. It consists of several modules. A microcontroller module serves as a control center whose task includes both controlling motors and communicating with computer. A motor module serves to handle motors. 10 sensors, including their signal conditionings, are introduced to read the environment conditions of the equipment. LEDs are used to display these conditions. In order to facilitate the operators’ duty, communication via RS232 is provided. The brachytherapy equipment can therefore be operated by using computer. Interface software is developed using C# language. To complete both mechanical and instrumentation systems performance, a safety system is developed to make sure that the safety for operator and patients from receiving excessive radiation. An interlock system is introduced to guard against abnormal conditions. In the worst case, a manual intervention

  3. Applicability and dosimetric impact of ultrasound-based preplanning in high-dose-rate brachytherapy of prostate cancer

    International Nuclear Information System (INIS)

    Aebersold, D.M.; Isaak, B.; Behrensmeier, F.; Kolotas, C.; Mini, R.; Greiner, R.H.; Thalmann, G.; Kranzbuehler, H.

    2004-01-01

    Background and purpose: analyses of permanent brachytherapy seed implants of the prostate have demonstrated that the use of a preplan may lead to a considerable decrease of dosimetric implant quality. The authors aimed to determine whether the same drawbacks of preplanning also apply to high-dose-rate (HDR) brachytherapy. Patients and methods: 15 patients who underwent two separate HDR brachytherapy implants in addition to external-beam radiation therapy for advanced prostate cancer were analyzed. A pretherapeutic transrectal ultrasound was performed in all patients to generate a preplan for the first brachytherapy implant. For the second brachytherapy, a subset of patients were treated by preplans based on the ultrasound from the first brachytherapy implant. Preplans were compared with the respective postplans assessing the following parameters: coverage index, minimum target dose, homogeneity index, and dose exposure of organs at risk. The prostate geometries (volume, width, height, length) were compared as well. Results: at the first brachytherapy, the matching between the preplan and actual implant geometry was sufficient in 47% of the patients, and the preplan could be applied. The dosimetric implant quality decreased considerably: the mean coverage differed by -0.11, the mean minimum target dose by -0.15, the mean homogeneity index by -0.09. The exposure of organs at risk was not substantially altered. At the second brachytherapy, all patients could be treated by the preplan; the differences between the implant quality parameters were less pronounced. The changes of prostate geometry between preplans and postplans were considerable, the differences in volume ranging from -8.0 to 13.8 cm 3 and in dimensions (width, height, length) from -1.1 to 1.0 cm. Conclusion: preplanning in HDR brachytherapy of the prostate is associated with a substantial decrease of dosimetric implant quality, when the preplan is based on a pretherapeutic ultrasound. The implant quality

  4. Current status of high dose rate brachytherapy in cervical cancer in Korea and optimal treatment schedule

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Seung Jae [College of Medicine, Sungkyunkwan Univ., Seoul (Korea, Republic of)

    1998-12-01

    Brachytherapy is an essential part of radiotherapy for uterine cervical cancer. The low dose rate (LDR) regimen has been the major technique of intracavitary therapy for cervical cancer. However, there has been an expansion in the last 20 years of high dose rate (HDR) machines using Ir-192 sources. Since 1979, HDR brachytherapy has been used for the treatment of uterine cervical cancer in Korea. The number of institutions employing HDR has been increasing, while the number of low dose rate system has been constant. In 1995, there was a total 27 HDR brachytherapy units installed and 1258 cases of patients with cervical cancer were treated with HDR. Most common regimens of HDR brachytherapy are total dose of 30-39 Gy at point A with 10-13 fractions in three fractions per week, 24-32 Gy with 6-8 fractions in two fractions per week, and 30-35 Gy with 6-7 fractions in two fractions per week. The average fractionation regimen of HDR brachytherapy is about 8 fractions of 4. 1 Gy each to point A. In Korea, treatment results for HDR brachytherapy are comparable with the LDR series and appears to be a safe and effective alternative to LDR therapy for the treatment of cervical carcinoma. Studies from the major centers report the five-year survival rate of cervical cancer as, 78-86% for Stage I, 68-85% for stage II, and 38-56% for Stage III. World-wide questionnaire study and Japanese questionnaire survey of multiple institutions showed no survival difference in any stages and dose-rate effect ratio (HDR/LDR) was calculated to be 0.54 to 0.58. However, the optimum treatment doses and fractionation schemes appropriate to generate clinical results comparable to conventional LDR schemes have yet to be standardized. In conclusion, HDR intracavitary radiotherapy is increasingly practiced in Korea and an effective treatment modality for cervical cancer. To determine the optimum radiotherapy dose and fractionation schedule, a nation-wide prospective study is necessary in Korea. In

  5. Custom-made micro applicators for high-dose-rate brachytherapy treatment of chronic psoriasis

    Directory of Open Access Journals (Sweden)

    Ivan M. Buzurovic

    2017-06-01

    Full Text Available Purpose: In this study, we present the treatment of the psoriatic nail beds of patients refractory to standard therapies using high-dose-rate (HDR brachytherapy. The custom-made micro applicators (CMMA were designed and constructed for radiation dose delivery to small curvy targets with complicated topology. The role of the HDR brachytherapy treatment was to stimulate the T cells for an increased immune response. Material and methods: The patient diagnosed with psoriatic nail beds refractory to standard therapies received monthly subunguinal injections that caused significant pain and discomfort in both hands. The clinical target was defined as the length from the fingertip to the distal interphalangeal joint. For the accurate and reproducible setup in the multi-fractional treatment delivery, the CMMAs were designed. Five needles were embedded into the dense plastic mesh and covered with 5 mm bolus material for each micro applicator. Five CMMAs were designed, resulting in the usage of 25 catheters in total. Results: The prescription dose was planned to the depth of the anterior surface of the distal phalanx, allowing for the sparing of the surrounding tissue. The total number of the active dwell positions was 145 with step size of 5 mm. The total treatment time was 115 seconds with a 7.36 Ci activity of the 192Ir source. The treatment resulted in good pain control. The patient did not require further injections to the nail bed. After this initial treatment, additional two patients with similar symptoms received HDR brachytherapy. The treatment outcome was favorable in all cases. Conclusions : The first HDR brachytherapy treatment of psoriasis of the nail bed is presented. The initial experience revealed that brachytherapy treatment was well-tolerated and resulted in adequate control of the disease. A larger cohort of patients will be required for additional conclusions related to the long-term clinical benefits.

  6. High-dose-rate brachytherapy in the treatment of skin Kaposi sarcoma

    Directory of Open Access Journals (Sweden)

    María Ángeles González Ruiz

    2017-12-01

    Full Text Available Purpose : The aim of the study is to review our experience in treatment of Kaposi sarcoma (KS lesions with high-dose-rate (HDR brachytherapy. Material and methods : We present five new KS lesions (three patients that were treated in our hospital from May 2016 to February 2017 with HDR brachytherapy using Valencia applicators. The treatment was delivered in 5 Gy fractions over five sessions, on alternate days. Total dose of 25 Gy (EQD2 31.25 Gy was delivered. All patients were male, Caucasian, without a history of HIV, organ transplantation, or current immunosuppressive therapy. The median age was 76 years. Results : All lesions (100% were located in lower limbs (60% in the ankle, 20% in the leg, and 20% in the foot, and their development was progressive. No lesion was greater than 2 cm (range, 0.5-1.5 cm. With a median follow-up of 15 months, all patients had a complete response to the treatment, with no evidence of local recurrence or tumor progression. Most of the patients (80% had no acute toxicity; only one patient developed erythema grade 2. Conclusions : HDR brachytherapy could be a good option of treatment for these types of lesions, especially in elderly patients, or when cosmetic results are not good after surgery. Brachytherapy with the Valencia applicator, using hypofractionated regimen provides excellent results in terms of cosmetic and local control, and furthermore, facilitates treatment compliance, which is very relevant in elderly patients. HDR brachytherapy offers a simple, safe, quick, and attractive non-surgical treatment option.

  7. Interstitial high dose rate brachytherapy for cancer of the oral tongue

    International Nuclear Information System (INIS)

    Nishimura, Tetsuo; Nozue, Masashi; Suzuki, Kazunori; Imai, Michiko; Iijima, Mitsuharu; Kaneko, Masao

    1997-01-01

    Between October 1992 and March 1996, 34 patients with cancer of the tongue without nodal metastases underwent fractionated interstitial brachytherapy with a high dose rate (HDR) iridium remote afterloader. The types of treatment consisted of brachytherapy (BT) alone: 8 cases, BT after surgery: 3 cases, BT after systemic chemotherapy: 3 cases, BT after arterial infusion (AI): 14 cases, BT after external beam radiotherapy (ERT): 5 cases, and BT after AI+ERT: 1 case. Applicators were implanted under general anesthesia. Reference dose was estimated at point 5 mm from source. Brachytherapy was carried out in 10 fractions twice a day for 5 days. Patients received 60 Gy with BT alone, 45-55 Gy after ERT, and 50-55 Gy after chemotherapy. Local failure was found in 5 cases with T2 lesions. Recurrence occurred in 5 out of 27 cases with tumor thickness of 10 mm or less. On the other hand, there were no recurrences in 7 cases with tumor thickness of more than 10 mm. Among various types of treatment, BT following systemic chemotherapy or AI exhibited better results (local failure: 1/17) than other modalities. Lymph node metastases appeared in 11 cases. Cause specific survival was 91% at 2 years in all cases. Ulcerations of the tongue were noted in 7 in 26 evaluable cases. Although ulceration occurred in 6/13 cases treated until March 1994, the incidence decreased to 1/13 afterwards. Careful implantation and dose prescription contributed to the decrease in ulceration. Ulcerative lesions healed with conservative care within 6 months in all cases. Bone exposure occurred in 2 cases that received 60 Gy following AI for advanced diseases. HDR fractionated brachytherapy may be a workable alternative to LDR therapy for cancer of the tongue. Brachytherapy following chemotherapy can be applied to more advanced cases of the disease. (K.H.)

  8. Monte Carlo dosimetry of the IRAsource high dose rate 192Ir brachytherapy source

    International Nuclear Information System (INIS)

    Sarabiasl, Akbar; Ayoobian, Navid; Jabbari, Iraj; Poorbaygi, Hossein; Javanshir, Mohammad Reza

    2016-01-01

    High-dose-rate (HDR) brachytherapy is a common method for cancer treatment in clinical brachytherapy. Because of the different source designs, there is a need for specific dosimetry data set for each HDR model. The purpose of this study is to obtain detailed dose rate distributions in water phantom for a first prototype HDR 192 Ir brachytherapy source model, IRAsource, and compare with the other published works. In this study, Monte Carlo N-particle (MCNP version 4C) code was used to simulate the dose rate distributions around the HDR source. A full set of dosimetry parameters reported by the American Association of Physicists in Medicine Task Group No. 43U1 was evaluated. Also, the absorbed dose rate distributions in water, were obtained in an along-away look-up table. The dose rate constant, Λ, of the IRAsource was evaluated to be equal to 1.112 ± 0.005 cGy h −1 U −1 . The results of dosimetry parameters are presented in tabulated and graphical formats and compared with those reported from other commercially available HDR 192 Ir sources, which are in good agreement. This justifies the use of specific data sets for this new source. The results obtained in this study can be used as input data in the conventional treatment planning systems.

  9. Radiation proctitis after the high dose rate brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Kitano, Masashi; Katsumata, Tomoe; Satoh, Takefumi

    2006-01-01

    We reviewed the medical records of 12 patients treated for rectal bleeding after high-dose rate brachytherapy for prostate cancer. All patients developed grade 2 proctitis according to the Common Terminology Criteria for Adverse Events (CTCAC) and no patients needed blood transfusion. The patients were treated with argon plasma coagulation (APC) and/or steroid suppositories. The bleeding stopped or improved in 11 patients. Although re-bleeding was noticed in 7 patients the same treatment was effective in 5 patients. (author)

  10. Salvage high-dose-rate interstitial brachytherapy for locally recurrent rectal cancer

    Directory of Open Access Journals (Sweden)

    Antônio Cássio Assis Pellizzon

    2016-06-01

    Full Text Available Abstract For tumors of the lower third of the rectum, the only safe surgical procedure is abdominal-perineal resection. High-dose-rate interstitial brachytherapy is a promising treatment for local recurrence of previously irradiated lower rectal cancer, due to the extremely high concentrated dose delivered to the tumor and the sparing of normal tissue, when compared with a course of external beam radiation therapy.

  11. Non-melanoma skin cancer treated with high-dose-rate brachytherapy: a review of literature

    OpenAIRE

    Durim Delishaj; Agata Rembielak; Bruno Manfredi; Stefano Ursino; Francesco Pasqualetti; Concetta Laliscia; Francesca Orlandi; Riccardo Morganti; Maria Grazia Fabrini; Fabiola Paiar

    2016-01-01

    Purpose: The incidence of non-melanoma skin cancer (NMSC) has been increasing over the past 30 years. There are different treatment options and surgical excision is the most frequent treatment due to its low rates of recurrence. Radiotherapy is an effective alternative of surgery, and brachytherapy (BT) might be a better therapeutic option due to high radiation dose concentration to the tumor with rapid dose fall-off resulting in normal tissues sparing. The aim of this review was to evaluate...

  12. Salvage high-dose-rate interstitial brachytherapy for locally recurrent rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pellizzon, Antonio Cassio Assis, E-mail: acapellizzon@hcancer.org.br [A.C. Camargo Cancer Center, Sao Paulo, SP (Brazil). Departamento de Radioterapia

    2016-05-15

    For tumors of the lower third of the rectum, the only safe surgical procedure is abdominal-perineal resection. High-dose-rate interstitial brachytherapy is a promising treatment for local recurrence of previously irradiated lower rectal cancer, due to the extremely high concentrated dose delivered to the tumor and the sparing of normal tissue, when compared with a course of external beam radiation therapy. (author)

  13. The brachytherapy with low dose-rate iridium for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Momma, Tetsuo; Saito, Shiro; Ohki, Takahiro; Satoh, Hiroyuki; Toya, Kazuhito; Dokiya, Takushi [National Tokyo Medical Center (Japan); Murai, Masaru

    2000-11-01

    Brachytherapy as an option for the treatment of prostate cancer has been commonly performed in USA. As the permanent seeding of the radioactive materials is strictly restricted by the law in Japan, brachytherapy must be performed by the temporary implant. This treatment has been performed at a few facilities in Japan mostly using high dose-rate iridium. Only our facility has been using low dose-rate iridium (LDR-Ir) for prostate cancer. This study evaluates the clinical results of the treatment. Since December 1997 to December 1999, 26 patients with histologically diagnosed as prostate cancer (Stage B, 92%; Stage C, 8%) underwent brachytherapy. Twenty-two patients received brachytherapy alone, three were treated with a combination of brachytherapy and external beam radiotherapy (ERT) and one was treated with a combination of brachytherapy and neoadjuvant endocrine therapy. Patients ranged in age from 61 to 84 (median 76) years old. Treatment was initiated with perineal needle placement. From 10 to 14 needles were placed through the holes on the template which was fixed to the stabilizer of the transrectal ultrasound probe. After the needle placement, CT scan was performed to draw distribution curves for the treatment planning. LDR-Ir wires were introduced to the sheath and indwelled during the time calculated from dosimetry. Peripheral dose was 70 Gy for the monotherapy of brachytherapy. For the combination therapy, 40 Gy was given by brachytherapy and 36 Gy with ERT afterwards. LDR-Ir wires were removed after completion of the radiation and patients were followed with serum PSA level and annual biopsy. During 2 to 26 (median 12) months follow-up, 8 out of 9 patients with initial PSA level above 20 ng/ml showed PSA failure. All 13 patients with initial PSA level lower than 20 ng/ml were free from PSA failure. Eight out of 11 patients with Gleason's score 7 or higher showed PSA failure, and all 14 patients (including three patients with combined therapy) with

  14. Pulsed dose rate brachytherapy (PDR): an analysis of the technique at 2 years

    Energy Technology Data Exchange (ETDEWEB)

    Thienpont, M. [Ghent Rijksuniversiteit (Belgium). Kliniek voor Radiotherapie en Kerngeneeskunde; Van Eijkeren, M.; Van Hecke, H.; Boterberg, T.; De Neve, W.

    1995-12-01

    A total of 154 applications was analysed using a pulsed dose brachytherapy technique for 138 patients over a 2 year period with emphasis on technical aspects influencing the overall treatment time. Vaginal ovoids were used in 59 cases, plastic tubes in 52, a Fletcher-type in 18, vaginal cylinders in 14 and a perineal template in 11 cases. Pulses were given at hourly intervals with a median dose rate of 0.6 Gy per pulse (range 0.4 to 3 Gy). The number of pulses per application varied from 3 to 134 (median 32). The number of dwell positions varied from 1 to 542 over 1 to 18 catheters. Patient related problems were few. The room was entered almost every 77 minutes. We noted 561 status codes in 147 applications. Of the 25 different codes, the most frequent one was due to the door left open when a pulse had to be given (35%) or due to constriction of the plastic catheters at the transfer tube junction (26%). However, the median total treatment time was increased by only 5 minutes. With pulsed dose rate brachytherapy at hourly pulses we can treat our patients within the planned time despite frequent room entrance and occurrence of an appreciable number of status codes. This technique seems to fulfill its promise to replace low dose rate brachytherapy.

  15. Low-dose-rate interstitial brachytherapy preserves good quality of life in buccal mucosa cancer patients

    International Nuclear Information System (INIS)

    Tayier, A.; Hayashi, Keiji; Yoshimura, Ryoichi

    2011-01-01

    The purpose of this study was to determine the results and long-term changes in radiation toxicity of stage I-II buccal mucosa cancer patients treated by low-dose-rate (LDR) brachytherapy with 198 Au grains. A total of 133 stage I-II buccal mucosa carcinomas patients received 198 Au grain implantation brachytherapy between January 1982 and July 2005: 75 of them were treated by 198 Au grain implantation alone and 58 were treated by 198 Au implantation in combination with external irradiation. The average 198 Au-grain dose was 70 Gy in 7 days. Gross tumor areas ranged from 2.4 cm 2 to 9 cm 2 , and the clinical target areas ranged from 6 cm 2 to 15 cm 2 . The follow-up periods ranged from 3 months to 20 years (mean: 5 years 11 months and median: 5 years 1 months). Failure at the site of the primary lesion occurred in 17 patients. Post-treatment mucosal ulceration developed in 15 patients, and all were cured within 25 months by conservative treatment. Osteoradionecrosis was diagnosed in 8 patients, but only one patient required surgical treatment. No severe complications or aggravation of complications developed more than 10 years after treatment. The results of low-dose-rate (LDR)-brachytherapy (BT) alone and LDR-BT in combination with external irradiation at a total dose of 25 Gy were acceptable from the standpoint of cure rate and quality of life (QOL). (author)

  16. Four year clinical statistics of iridium-192 high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Shigehara, Kazuyoshi; Mizokami, Atsushi; Komatsu, Kazuto; Koshida, Kiyoshi; Namiki, Mikio

    2006-01-01

    We evaluated the efficacy and complications of high dose rate (HDR) brachytherapy using iridium-192 ( 192 Ir) combined with external beam radiotherapy (EBRT) in patients with prostate cancer. Ninety-seven patients underwent 192 Ir HDR brachytherapy combined with EBRT at our institution between February 1999 and December 2003. Of these, 84 patients were analysed in the present study. 192 Ir was delivered three times over a period of 2 days, 6 Gy per time, for a total dose of 18 Gy. Interstitial application was followed by EBRT at a dose of 44 Gy. Progression was defined as three consecutive prostate-specific antigen (PSA) rises after a nadir according to the American Society for Therapeutic Radiology and Oncology criteria. The results were classified into those for all patients and for patients who did not undergo adjuvant hormone therapy. The 4-year overall survival of all patients, the nonadjuvant hormone therapy group (NAHT) and the adjuvant hormone therapy group (AHT) was 87.2%, 100%, and 70.1%, respectively. The PSA progression-free survival rate of all patients, NAHT, and AHT was 82.6%, 92.0%, and 66.6%, respectively. Of all patients, the 4-year PSA progression-free survival rates of PSA 192 Ir HDR brachytherapy combined with EBRT was as effective as radical prostatectomy and had few associated complications. (author)

  17. Treatment Outcome of Medium-Dose-Rate Intracavitary Brachytherapy for Carcinoma of the Uterine Cervix: Comparison With Low-Dose-Rate Intracavitary Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kaneyasu, Yuko, E-mail: kaneyasu@hiroshima-u.ac.jp [Department of Radiation Oncology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima (Japan); Department of Radiation Oncology, Tokyo Women' s Medical University, Tokyo (Japan); Kita, Midori [Department of Radiation Oncology, Tokyo Women' s Medical University, Tokyo (Japan); Department of Clinical Radiology, Tokyo Metropolitan Tama Medical Center, Tokyo (Japan); Okawa, Tomohiko [Evaluation and Promotion Center, Utsunomiya Memorial Hospital, Tochigi (Japan); Maebayashi, Katsuya [Department of Radiation Oncology, Tokyo Women' s Medical University, Tokyo (Japan); Kohno, Mari [Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Women' s Medical University Hospital, Tokyo (Japan); Sonoda, Tatsuo; Hirabayashi, Hisae [Department of Radiology, Tokyo Women' s Medical University Hospital, Tokyo (Japan); Nagata, Yasushi [Department of Radiation Oncology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima (Japan); Mitsuhashi, Norio [Department of Radiation Oncology, Tokyo Women' s Medical University, Tokyo (Japan)

    2012-09-01

    Purpose: To evaluate and compare the efficacy of medium-dose-rate (MDR) and low-dose-rate (LDR) intracavitary brachytherapy (ICBT) for uterine cervical cancer. Methods and Materials: We evaluated 419 patients with squamous cell carcinoma of the cervix who were treated by radical radiotherapy with curative intent at Tokyo Women's Medical University from 1969 to 1999. LDR was used from 1969 to 1986, and MDR has been used since July 1987. When compared with LDR, fraction dose was decreased and fraction size was increased (1 or 2 fractions) for MDR to make the total dose of MDR equal to that of LDR. In general, the patients received a total dose of 60 to 70 Gy at Point A with external beam radiotherapy combined with brachytherapy according to the International Federation of Gynecology and Obstetrics stage. In the LDR group, 32 patients had Stage I disease, 81 had Stage II, 182 had Stage III, and 29 had Stage IVA; in the MDR group, 9 patients had Stage I disease, 19 had Stage II, 55 had Stage III, and 12 had Stage IVA. Results: The 5-year overall survival rates for Stages I, II, III, and IVA in the LDR group were 78%, 72%, 55%, and 34%, respectively. In the MDR group, the 5-year overall survival rates were 100%, 68%, 52%, and 42%, respectively. No significant statistical differences were seen between the two groups. The actuarial rates of late complications Grade 2 or greater at 5 years for the rectum, bladder, and small intestine in the LDR group were 11.1%, 5.8%, and 2.0%, respectively. The rates for the MDR group were 11.7%, 4.2%, and 2.6%, respectively, all of which were without statistical differences. Conclusion: These data suggest that MDR ICBT is effective, useful, and equally as good as LDR ICBT in daytime (about 5 hours) treatments of patients with cervical cancer.

  18. Clinical outcome of high-dose-rate interstitial brachytherapy in patients with oral cavity cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sung Uk; Cho, Kwan Ho; Moon, Sung Ho; Choi, Sung Weon; Park, Joo Yong; Yun, Tak; Lee, Sang Hyun; Lim, Young Kyung; Jeong, Chi Young [National Cancer Center, Goyang (Korea, Republic of)

    2014-12-15

    To evaluate the clinical outcome of high-dose-rate (HDR) interstitial brachytherapy (IBT) in patients with oral cavity cancer. Sixteen patients with oral cavity cancer treated with HDR remote-control afterloading brachytherapy using 192Ir between 2001 and 2013 were analyzed retrospectively. Brachytherapy was administered in 11 patients as the primary treatment and in five patients as salvage treatment for recurrence after the initial surgery. In 12 patients, external beam radiotherapy (50-55 Gy/25 fractions) was combined with IBT of 21 Gy/7 fractions. In addition, IBT was administered as the sole treatment in three patients with a total dose of 50 Gy/10 fractions and as postoperative adjuvant treatment in one patient with a total of 35 Gy/7 fractions. The 5-year overall survival of the entire group was 70%. The actuarial local control rate after 3 years was 84%. All five recurrent cases after initial surgery were successfully salvaged using IBT +/- external beam radiotherapy. Two patients developed local recurrence at 3 and 5 months, respectively, after IBT. The acute complications were acceptable (< or =grade 2). Three patients developed major late complications, such as radio-osteonecrosis, in which one patient was treated by conservative therapy and two required surgical intervention. HDR IBT for oral cavity cancer was effective and acceptable in diverse clinical settings, such as in the cases of primary or salvage treatment.

  19. High dose rate brachytherapy using molds after chemoradiotherapy for oral cavity cancer

    International Nuclear Information System (INIS)

    Chatani, Masashi; Tsuboi, Kazuki; Yagi, Masayuki; Fujiwara, Kanta; Tachimoto, Rika; Yoshioka, Hideo

    2012-01-01

    The aim of this study was to investigate the role of the combined use of customized molds and a high dose rate (HDR) remote afterloading brachytherapy apparatus with a 192 Ir microsource in the treatment of superficial oral carcinomas after chemoradiotherapy. Nine patients with oral squamous cell carcinoma who were treated using this combined technique were analyzed retrospectively. The primary sites of the tumors were the mouth floor, gingiva, and soft palate. For each patient, a customized mold was fabricated in which 2-3 afterloading catheters were placed for the 192 Ir source. Three to eight fractions of 3 Gy, 5 mm below the mold surface, were given following external radiotherapy of 24-50 Gy/2 Gy combined with chemotherapy (peplomycin or taxotere). The total dose of HDR brachytherapy ranged from 9 to 24 Gy. The 2-year local control probability was 100% and the 2-year cause-specific survival rate was 100%. No serious complications (id est (i.e.), ulcer or bone exposure) have been observed thus far during the follow-up period of 29-120 months. HDR brachytherapy using the mold technique after chemoradiotherapy is a safe and excellent method for selected early and superficial oral cavity cancers. (author)

  20. Independent technique of verifying high-dose rate (HDR) brachytherapy treatment plans

    International Nuclear Information System (INIS)

    Saw, Cheng B.; Korb, Leroy J.; Darnell, Brenda; Krishna, K. V.; Ulewicz, Dennis

    1998-01-01

    Purpose: An independent technique for verifying high-dose rate (HDR) brachytherapy treatment plans has been formulated and validated clinically. Methods and Materials: In HDR brachytherapy, dwell times at respective dwell positions are computed, using an optimization algorithm in a HDR treatment-planning system to deliver a specified dose to many target points simultaneously. Because of the variability of dwell times, concerns have been expressed regarding the ability of the algorithm to compute the correct dose. To address this concern, a commercially available low-dose rate (LDR) algorithm was used to compute the doses at defined distances, based on the dwell times obtained from the HDR treatment plans. The percent deviation between doses computed using the HDR and LDR algorithms were reviewed for HDR procedures performed over the last year. Results: In this retrospective study, the difference between computed doses using the HDR and LDR algorithms was found to be within 5% for about 80% of the HDR procedures. All of the reviewed procedures have dose differences of less than 10%. Conclusion: An independent technique for verifying HDR brachytherapy treatment plans has been validated based on clinical data. Provided both systems are available, this technique is universal in its applications and not limited to either a particular implant applicator, implant site, or implant type

  1. Impact of catheter reconstruction error on dose distribution in high dose rate intracavitary brachytherapy and evaluation of OAR doses

    International Nuclear Information System (INIS)

    Thaper, Deepak; Shukla, Arvind; Rathore, Narendra; Oinam, Arun S.

    2016-01-01

    In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this study is to evaluate the impact of catheter reconstruction error on dose distribution in CT based intracavitary brachytherapy planning and evaluation of its effect on organ at risk (OAR) like bladder, rectum and sigmoid and target volume High risk clinical target volume (HR-CTV)

  2. Quality assurance of Vari-source high dose rate (HDR) brachytherapy- remote after loader and cost effectiveness of Vari-source HDR- brachytherapy: NORI, Islamabad experience

    International Nuclear Information System (INIS)

    Ahmad, N.; Mahmood, H.; Jafri, S.R.A.

    2004-01-01

    A quality control of Vari-Source high dose rate (HDR) remote after loading brachytherapy machine was carried out and the cost effectiveness of HDR brachytherapy machine was also evaluated considering the cost of ten Iridium-192 wire sources at Nuclear Medicine, Oncology and Radiotherapy Institute (NORI), Islamabad, Pakistan. A total number of 253 intracavitary insertions were done in 98 patients from October 1996 to May 2001. The results of the quality control tests performed during 1996 to 2001 were within the acceptable limits. The cost effectiveness of Vari-Source HDR brachytherapy machine was also evaluated. The average cost per patient was calculated as US$ 491. Small number of patients was treated as the machine was used for gynecologic malignancies only. The objective was to assess the quality control status of HDR brachytherapy machine on patient treatment day, source exchange day and periodic day (monthly basis). It was found that the cost per patient can be minimized if other type of cancer patients are also treated on Vari-Source HDR machine. (author)

  3. The status of low dose rate and future of high dose rate Cf-252 brachytherapy

    International Nuclear Information System (INIS)

    Rivard, M.J.; Wierzbicki, J.G.; Van den Heuvel, F.; Chuba, P.J.; Fontanesi, J.

    1997-12-01

    This work describes the current status of the US low dose rate (LDR) Cf-252 brachytherapy program. The efforts undertaken towards development of a high dose rate (HDR) remotely after loaded Cf-252 source, which can accommodate 1 mg or greater Cf-252, are also described. This HDR effort is a collaboration between Oak Ridge National Laboratory (ORNL), commercial remote after loader manufactures, the Gershenson Radiation Oncology Center (ROC), and Wayne State University. To achieve this goal, several advances in isotope chemistry and source preparation at ORNL must be achieved to yield a specific material source loading of greater than or equal 1 mg Cf-252 per mm3. Development work with both radioactive and non-radioactive stand-ins for Cf-252 have indicated the feasibility of fabricating such sources. As a result, the decreased catheter diameter and computer controlled source placement will permit additional sites (e.g. brain, breast, prostate, lung, parotid, etc.) to be treated effectively with Cf-252 sources. Additional work at the Radiochemical Engineering and Development Center (REDC) remains in source fabrication, after loader modification, and safe design. The current LDR Cf-252 Treatment Suite at the ROC is shielded and licensed to hold up to 1 mg of Cf-252. This was designed to maintain cumulative personnel exposure, both external to the room and in direct isotope handling, at less than 20 microSv/hr. However, cumulative exposure may be greatly decreased if a Cf-252 HDR unit is employed which would eliminate direct isotope handling and decrease treatment times from tilde 3 hours to an expected range of 3 to 15 minutes. Such a Cf-252 HDR source will also demonstrate improved dose distributions over current LDR treatments due to the ability to step the point-like source throughout the target volume and weight the dwell time accordingly

  4. Comparison of high-dose-rate and low-dose-rate brachytherapy in the treatment of endometrial carcinoma

    International Nuclear Information System (INIS)

    Fayed, Alaa; Mutch, David G.; Rader, Janet S.; Gibb, Randall K.; Powell, Matthew A.; Wright, Jason D.; El Naqa, Issam; Zoberi, Imran; Grigsby, Perry W.

    2007-01-01

    Purpose: To compare the outcomes for endometrial carcinoma patients treated with either high-dose-rate (HDR) or low-dose-rate (LDR) brachytherapy. Methods and Materials: This study included 1,179 patients divided into LDR (1,004) and HDR groups (175). Patients with International Federation of Gynecology and Obstetrics (FIGO) surgical Stages I-III were included. All patients were treated with postoperative irradiation. In the LDR group, the postoperative dose applied to the vaginal cuff was 60-70 Gy surface doses to the vaginal mucosa. The HDR brachytherapy prescription was 6 fractions of 2 Gy each to a depth of 0.5 cm from the surface of the vaginal mucosa. Overall survival, disease-free survival, local control, and complications were endpoints. Results: For all stages combined, the overall survival, disease-free survival, and local control at 5 years in the LDR group were 70%, 69%, and 81%, respectively. For all stages combined, the overall survival, disease-free survival, and local control at 5 years in the HDR group were 68%, 62%, and 78%, respectively. There were no significant differences in early or late Grade III and IV complications in the HDR or LDR groups. Conclusion: Survival outcomes, pelvic tumor control, and Grade III and IV complications were not significantly different in the LDR brachytherapy group compared with the HDR group

  5. Brachytherapy in childhood rhabdomyosarcoma treatment

    International Nuclear Information System (INIS)

    Novaes, Paulo Eduardo Ribeiro dos Santos

    1995-01-01

    A retrospective study of 21 children with rhabdomyosarcoma treated by brachytherapy to the primary site of the tumor at the Radiotherapy Department of the A.C.Camargo Hospital between january/1980 to june/1993 was undertaken. The main objectives were to comprove the utility of brachytherapy in childhood rhabdomyosarcoma, to evaluate the local control and survival, in association with chemotherapy, to analyze the late effects of the treatment and to determinate the preferential technique to each clinical situation. All patients received brachytherapy to the tumor site. The radioactive isotopes employed were Gold 198 , Cesium 137 and Iridium 192 . The brachytherapy techniques depended on the tumor site, period of treatment, availability of the radioactive material and stage of the disease. Patients treated exclusively by brachytherapy received 40 Gy to 60 Gy. When brachytherapy was associated with external radiotherapy the dose ranged from 20 Gy to 40 Gy. Local control was achieved in 18 of 20 patients (90%). The global survival and local control survival rates were 61.9% (13/21 patients) and 72,2% (13/18 patients) respectively. (author)

  6. Non-melanoma skin cancer treated with high-dose-rate brachytherapy: a review of literature

    Directory of Open Access Journals (Sweden)

    Durim Delishaj

    2016-12-01

    Full Text Available Purpose: The incidence of non-melanoma skin cancer (NMSC has been increasing over the past 30 years. There are different treatment options and surgical excision is the most frequent treatment due to its low rates of recurrence. Radiotherapy is an effective alternative of surgery, and brachytherapy (BT might be a better therapeutic option due to high radiation dose concentration to the tumor with rapid dose fall-off resulting in normal tissues sparing. The aim of this review was to evaluate the local control, toxicity, and cosmetic outcomes in NMSC treated with high-dose-rate BT (HDR-BT. Material and methods: In May 2016, a systematic search of bibliographic database of PubMed, Web of Science, Scopus, and Cochrane Library with a combination of key words of “skin cancer”, “high dose rate brachytherapy”, “squamous cell carcinoma”, “basal cell carcinoma”, and “non melanoma skin cancer“ was performed. In this systematic review, we included randomized trials, non-randomized trials, prospective and retrospective studies in patients affected by NMSC treated with HDR-BT. Results: Our searches generated a total of 85 results, and through a process of screening, 10 publications were selected for the review. Brachytherapy was well tolerated with acceptable toxicity and high local control rates (median: 97%. Cosmetic outcome was reported in seven study and consisted in an excellent and good cosmetic results in 94.8% of cases. Conclusions : Based on the review data, we can conclude that the treatment of NMSC with HDR-BT is effective with excellent and good cosmetics results, even in elderly patients. The hypofractionated course appears effective with very good local disease control. More data with large-scale randomized controlled trials are needed to assess the efficacy and safety of brachytherapy.

  7. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer

    International Nuclear Information System (INIS)

    Martinez, Alvaro A.; Gustafson, Gary; Gonzalez, Jose; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-01-01

    Purpose: To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Methods and Materials: Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level ≥10.0 ng/mL, Gleason score ≥7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. Results: The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p<0.001). Improvement occurred in the cause-specific survival in favor of the brachytherapy high-dose level (p=0.014). On multivariate analysis, a low-dose level, higher Gleason score, and higher nadir value were associated with increased biochemical failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Conclusion: Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause

  8. MRI dosimetry using an echo-quotient technique for high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Ansbacher, W.

    1996-01-01

    MRI gel dosimetry is a relatively new technique that has many advantages over conventional methods, and is particularly suited to High Dose Rate (HDR) Brachytherapy. The dosimeter has high spatial resolution and a water-equivalent response over a wide range of photon energies. Because it is an integrating dosimeter, it allows for efficient mapping of the dynamically-produced distributions from an HDR source. As an example of this technique, the dose response, which is calibrated in terms of the change in spin-spin relaxation time, has been used to investigate the anisotropy of an HDR source. (author). 1 fig

  9. Pulsed dose rate (PDR) brachytherapy as salvage treatment of locally advanced or recurrent gynecologic cancer

    DEFF Research Database (Denmark)

    Jensen, P T; Roed, H; Engelholm, S A

    1998-01-01

    been treated with external irradiation, four-field box technique, to 46 Gy/23 fractions, 5 F/week and 192Ir-interstitial PDR-brachytherapy in pulses of 0.6 Gy, one pulse per hour to a total of 30 Gy. The Martinez Universal Perineal Interstitial Template applicator was used for all implantations....... RESULTS: The overall complete response rate was 74%. At median 14 months follow-up (range 3-40) 15 patients were alive with no evidence of disease. Seven of 14 patients with a second recurrence or progressive disease were still alive. The overall 1- and 2-year survival was 71% and 63%, respectively...

  10. Comparison between calculation methods of dose rates in gynecologic brachytherapy

    International Nuclear Information System (INIS)

    Vianello, E.A.; Biaggio, M.F.; D R, M.F.; Almeida, C.E. de

    1998-01-01

    In treatments with radiations for gynecologic tumors is necessary to evaluate the quality of the results obtained by different calculation methods for the dose rates on the points of clinical interest (A, rectal, vesicle). The present work compares the results obtained by two methods. The Manual Calibration Method (MCM) tri dimensional (Vianello E., et.al. 1998), using orthogonal radiographs for each patient in treatment, and the Theraplan/T P-11 planning system (Thratonics International Limited 1990) this last one verified experimentally (Vianello et.al. 1996). The results show that MCM can be used in the physical-clinical practice with a percentile difference comparable at the computerized programs. (Author)

  11. Development of a reference system and a methodology for the calibration of ophthalmic applicators utilized in brachytherapy

    International Nuclear Information System (INIS)

    Oliveira, Mercia Liane de

    2005-01-01

    90 Sr+ 90 Y beta radiation sources are widely utilized in brachytherapy, in the treatment of superficial lesions of eyes and skin. According to international recommendations, these applicators should be specified in terms of the absorbed dose rate to water at the reference point (1 mm from the source surface, along its axis of symmetry). Two mini-extrapolation chambers were developed with adequate geometrical characteristics for the dosimetry of plane and concave 90 Sr+ 90 Y sources. These chambers have 3.0 cm of outer diameter and 11.3 cm of length. Aluminized polyester foils are used as entrance windows, and the collecting electrodes were made of graphited polymethylmethacrylate. The mini-chambers were tested in 90 Sr+ 90 Y radiation beams from a beta check source and plane and concave ophthalmic applicators. All results obtained show the usefulness of these chambers as reference primary standards for the calibration of 90 Sr+ 90 Y applicators. The previous calibration of the mini-chambers in relation to a standard ionization chamber or to a standard beta source is unnecessary. The minichamber with plane window showed utility for low energy X-rays too. In order to establish an alternative method for the calibration of beta radiation sources, different thermoluminescent materials were tested: LiF, CaF 2 :Mn, CaF 2 :Dy and CaS0 4 :Dy. For their characterization, the response reproducibility, calibration curves, TL response as a function of the source-detector distance, transmission factors and the linearity of the sample response were determined. The calibration procedures of ophthalmic applicators were established utilizing the ionometric technique and thermoluminescence dosimetry. (author)

  12. Predictors of Toxicity After Image-guided High-dose-rate Interstitial Brachytherapy for Gynecologic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Larissa J. [Department of Radiation Oncology, Brigham and Women' s Hospital and Dana-Farber Cancer Institute, Harvard Medical School, Boston, Massachusetts (United States); Viswanathan, Akila N., E-mail: aviswanathan@lroc.harvard.edu [Department of Radiation Oncology, Brigham and Women' s Hospital and Dana-Farber Cancer Institute, Harvard Medical School, Boston, Massachusetts (United States)

    2012-12-01

    Purpose: To identify predictors of grade 3-4 complications and grade 2-4 rectal toxicity after three-dimensional image-guided high-dose-rate (HDR) interstitial brachytherapy for gynecologic cancer. Methods and Materials: Records were reviewed for 51 women (22 with primary disease and 29 with recurrence) treated with HDR interstitial brachytherapy. A single interstitial insertion was performed with image guidance by computed tomography (n = 43) or magnetic resonance imaging (n = 8). The median delivered dose in equivalent 2-Gy fractions was 72.0 Gy (45 Gy for external-beam radiation therapy and 24 Gy for brachytherapy). Toxicity was reported according to the Common Toxicity Criteria for Adverse Events. Actuarial toxicity estimates were calculated by the Kaplan-Meier method. Results: At diagnosis, the median patient age was 62 years and the median tumor size was 3.8 cm. The median D90 and V100 were 71.4 Gy and 89.5%; the median D2cc for the bladder, rectum, and sigmoid were 64.6 Gy, 61.0 Gy, and 52.7 Gy, respectively. The actuarial rates of all grade 3-4 complications at 2 years were 20% gastrointestinal, 9% vaginal, 6% skin, 3% musculoskeletal, and 2% lymphatic. There were no grade 3-4 genitourinary complications and no grade 5 toxicities. Grade 2-4 rectal toxicity was observed in 10 patients, and grade 3-4 complications in 4; all cases were proctitis with the exception of 1 rectal fistula. D2cc for rectum was higher for patients with grade 2-4 (68 Gy vs 57 Gy for grade 0-1, P=.03) and grade 3-4 (73 Gy vs 58 Gy for grade 0-2, P=.02) rectal toxicity. The estimated dose that resulted in a 10% risk of grade 2-4 rectal toxicity was 61.8 Gy (95% confidence interval, 51.5-72.2 Gy). Discussion: Image-guided HDR interstitial brachytherapy results in acceptable toxicity for women with primary or recurrent gynecologic cancer. D2cc for the rectum is a reliable predictor of late rectal complications. Three-dimensional-based treatment planning should be performed to ensure

  13. Predictors of Toxicity After Image-guided High-dose-rate Interstitial Brachytherapy for Gynecologic Cancer

    International Nuclear Information System (INIS)

    Lee, Larissa J.; Viswanathan, Akila N.

    2012-01-01

    Purpose: To identify predictors of grade 3-4 complications and grade 2-4 rectal toxicity after three-dimensional image-guided high-dose-rate (HDR) interstitial brachytherapy for gynecologic cancer. Methods and Materials: Records were reviewed for 51 women (22 with primary disease and 29 with recurrence) treated with HDR interstitial brachytherapy. A single interstitial insertion was performed with image guidance by computed tomography (n = 43) or magnetic resonance imaging (n = 8). The median delivered dose in equivalent 2-Gy fractions was 72.0 Gy (45 Gy for external-beam radiation therapy and 24 Gy for brachytherapy). Toxicity was reported according to the Common Toxicity Criteria for Adverse Events. Actuarial toxicity estimates were calculated by the Kaplan-Meier method. Results: At diagnosis, the median patient age was 62 years and the median tumor size was 3.8 cm. The median D90 and V100 were 71.4 Gy and 89.5%; the median D2cc for the bladder, rectum, and sigmoid were 64.6 Gy, 61.0 Gy, and 52.7 Gy, respectively. The actuarial rates of all grade 3-4 complications at 2 years were 20% gastrointestinal, 9% vaginal, 6% skin, 3% musculoskeletal, and 2% lymphatic. There were no grade 3-4 genitourinary complications and no grade 5 toxicities. Grade 2-4 rectal toxicity was observed in 10 patients, and grade 3-4 complications in 4; all cases were proctitis with the exception of 1 rectal fistula. D2cc for rectum was higher for patients with grade 2-4 (68 Gy vs 57 Gy for grade 0-1, P=.03) and grade 3-4 (73 Gy vs 58 Gy for grade 0-2, P=.02) rectal toxicity. The estimated dose that resulted in a 10% risk of grade 2-4 rectal toxicity was 61.8 Gy (95% confidence interval, 51.5-72.2 Gy). Discussion: Image-guided HDR interstitial brachytherapy results in acceptable toxicity for women with primary or recurrent gynecologic cancer. D2cc for the rectum is a reliable predictor of late rectal complications. Three-dimensional-based treatment planning should be performed to ensure

  14. Perioperative fractionated high-dose rate brachytherapy for malignant bone and soft tissue tumors

    International Nuclear Information System (INIS)

    Koizumi, Masahiko; Inoue, Takehiro; Yamazaki, Hideya; Teshima, Teruki; Tanaka, Eiichi; Yoshida, Ken; Imai, Atsushi; Shiomi, Hiroya; Kagawa, Kazufumi; Araki, Nobuto; Kuratsu, Shigeyuki; Uchida, Atsumasa; Inoue, Toshihiko

    1999-01-01

    Purpose: To investigate the viability of perioperative fractionated HDR brachytherapy for malignant bone and soft tissue tumors, analyzing the influence of surgical margin. Methods and Materials: From July 1992 through May 1996, 16 lesions of 14 patients with malignant bone and soft tissue tumors (3 liposarcomas, 3 MFHs, 2 malignant schwannomas, 2 chordomas, 1 osteosarcoma, 1 leiomyosarcoma, 1 epithelioid sarcoma, and 1 synovial sarcoma) were treated at the Osaka University Hospital. The patients' ages ranged from 14 to 72 years (median: 39 years). Treatment sites were the pelvis in 6 lesions, the upper limbs in 5, the neck in 4, and a lower limb in 1. The resection margins were classified as intracapsular in 5 lesions, marginal in 5, and wide in 6. Postoperative fractionated HDR brachytherapy was started on the 4th-13th day after surgery (median: 6th day). The total dose was 40-50 Gy/7-10 fr/ 4-7 day (bid) at 5 or 10 mm from the source. Follow-up periods were between 19 and 46 months (median: 30 months). Results: Local control rates were 75% at 1 year and 48% in 2 years, and ultimate local control was achieved in 8 (50%) of 16 lesions. Of the 8 uncontrolled lesions, 5 (63%) had intracapsular (macroscopically positive) resection margins, and all the 8 controlled lesions (100%) had marginal (microscopically positive) or wide (negative) margins. Of the total, 3 patients died of both tumor and metastasis, 3 of metastasis alone, 1 of tumor alone, and 7 showed no evidence of disease. Peripheral nerve palsy was seen in one case after this procedure, but no infection or delayed wound healing caused by tubing or irradiation has occurred. Conclusion: Perioperative fractionated HDR brachytherapy is safe, well tolerated, and applicable to marginal or wide surgical margin cases

  15. A method for verification of treatment times for high-dose-rate intraluminal brachytherapy treatment

    Directory of Open Access Journals (Sweden)

    Muhammad Asghar Gadhi

    2016-06-01

    Full Text Available Purpose: This study was aimed to increase the quality of high dose rate (HDR intraluminal brachytherapy treatment. For this purpose, an easy, fast and accurate patient-specific quality assurance (QA tool has been developed. This tool has been implemented at Bahawalpur Institute of Nuclear Medicine and Oncology (BINO, Bahawalpur, Pakistan.Methods: ABACUS 3.1 Treatment planning system (TPS has been used for treatment planning and calculation of total dwell time and then results were compared with the time calculated using the proposed method. This method has been used to verify the total dwell time for different rectum applicators for relevant treatment lengths (2-7 cm and depths (1.5-2.5 cm, different oesophagus applicators of relevant treatment lengths (6-10 cm and depths (0.9 & 1.0 cm, and a bronchus applicator for relevant treatment lengths (4-7.5 cm and depth (0.5 cm.Results: The average percentage differences between treatment time TM with manual calculation and as calculated by the TPS is 0.32% (standard deviation 1.32% for rectum, 0.24% (standard deviation 2.36% for oesophagus and 1.96% (standard deviation 0.55% for bronchus, respectively. These results advocate that the proposed method is valuable for independent verification of patient-specific treatment planning QA.Conclusion: The technique illustrated in the current study is an easy, simple, quick and useful for independent verification of the total dwell time for HDR intraluminal brachytherapy. Our method is able to identify human error-related planning mistakes and to evaluate the quality of treatment planning. It enhances the quality of brachytherapy treatment and reliability of the system.

  16. Interfraction patient motion and implant displacement in prostate high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Fox, C. D.; Kron, T.; Leahy, M.; Duchesne, G.; Williams, S.; Tai, K. H.; Haworth, A.; Herschtal, A.; Foroudi, F.

    2011-01-01

    Purpose: To quantify movement of prostate cancer patients undergoing treatment, using an in-house developed motion sensor in order to determine a relationship between patient movement and high dose rate (HDR) brachytherapy implant displacement. Methods: An electronic motion sensor was developed based on a three axis accelerometer. HDR brachytherapy treatment for prostate is delivered at this institution in two fractions 24 h apart and 22 patients were monitored for movement over the interval between fractions. The motion sensors functioned as inclinometers, monitoring inclination of both thighs, and the inclination and roll of the abdomen. The implanted HDR brachytherapy catheter set was assessed for displacement relative to fiducial markers in the prostate. Angle measurements and angle differences over a 2 s time base were binned, and the standard deviations of the resulting frequency distributions used as a metric for patient motion in each monitored axis. These parameters were correlated to measured catheter displacement using regression modeling. Results: The mean implant displacement was 12.6 mm in the caudal direction. A mean of 19.95 h data was recorded for the patient cohort. Patients generally moved through a limited range of angles with a mean of the exception of two patients who spent in excess of 2 h lying on their side. When tested for a relationship between movement in any of the four monitored axes and the implant displacement, none was significant. Conclusions: It is not likely that patient movement influences HDR prostate implant displacement. There may be benefits to patient comfort if nursing protocols were relaxed to allow patients greater freedom to move while the implant is in situ.

  17. Interfraction patient motion and implant displacement in prostate high dose rate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Fox, C. D.; Kron, T.; Leahy, M.; Duchesne, G.; Williams, S.; Tai, K. H.; Haworth, A.; Herschtal, A.; Foroudi, F. [Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria 3002 (Australia); Nursing Service, Peter MacCallum Cancer Centre, Melbourne, Victoria 3002 (Australia); Department of Radiation Oncology, Peter MacCallum Cancer Centre and University of Melbourne, Melbourne, Victoria 3002 (Australia); Department of Physical Sciences, Peter MacCallum Cancer Centre and Royal Melbourne Insititute of Technology, Melbourne, Victoria 3000 (Australia); Department of Biostatistics and Clinical Trials, Peter MacCallum Cancer Centre, Melbourne, Victoria 3002 (Australia); Department of Radiation Oncology, Peter MacCallum Cancer Centre and University of Melbourne, Melbourne, Victoria 3010 (Australia)

    2011-11-15

    Purpose: To quantify movement of prostate cancer patients undergoing treatment, using an in-house developed motion sensor in order to determine a relationship between patient movement and high dose rate (HDR) brachytherapy implant displacement. Methods: An electronic motion sensor was developed based on a three axis accelerometer. HDR brachytherapy treatment for prostate is delivered at this institution in two fractions 24 h apart and 22 patients were monitored for movement over the interval between fractions. The motion sensors functioned as inclinometers, monitoring inclination of both thighs, and the inclination and roll of the abdomen. The implanted HDR brachytherapy catheter set was assessed for displacement relative to fiducial markers in the prostate. Angle measurements and angle differences over a 2 s time base were binned, and the standard deviations of the resulting frequency distributions used as a metric for patient motion in each monitored axis. These parameters were correlated to measured catheter displacement using regression modeling. Results: The mean implant displacement was 12.6 mm in the caudal direction. A mean of 19.95 h data was recorded for the patient cohort. Patients generally moved through a limited range of angles with a mean of the exception of two patients who spent in excess of 2 h lying on their side. When tested for a relationship between movement in any of the four monitored axes and the implant displacement, none was significant. Conclusions: It is not likely that patient movement influences HDR prostate implant displacement. There may be benefits to patient comfort if nursing protocols were relaxed to allow patients greater freedom to move while the implant is in situ.

  18. Reirradiation for recurrent head and neck cancer with salvage interstitial pulsed-dose-rate brachytherapy. Long-term results

    Energy Technology Data Exchange (ETDEWEB)

    Strnad, Vratislav; Lotter, Michael; Kreppner, Stephan; Fietkau, Rainer [University Hospital Erlangen, Dept. of Radiation Oncology, Erlangen (Germany)

    2015-01-10

    To assess the long-term results of protocol-based interstitial pulsed-dose-rate (PDR) brachytherapy as reirradiation combined with simultaneous chemotherapy and interstitial hyperthermia in selected patients with recurrent head and neck tumors. A total of 104 patients with biopsy-proven recurrent head and neck cancer were treated with interstitial PDR brachytherapy. Salvage surgery had also been undergone by 53/104 (51 %) patients (R1 or R2 resection in > 80 % of patients). Salvage brachytherapy alone was administered in 81 patients (78 %), with a median total dose of 56.7 Gy. Salvage brachytherapy in combination with external beam radiotherapy (EBRT) was performed in 23/104 patients (32 %), using a median total dose of D{sub REF} = 24 Gy. Simultaneously to PDR brachytherapy, concomitant chemotherapy was administered in 58/104 (55.8 %) patients. A single session of interstitial hyperthermia was also used to treat 33/104 (31.7 %) patients. The analysis was performed after a median follow-up of 60 months. Calculated according to Kaplan-Meier, local tumor control rates after 2, 5, and 10 years were 92.5, 82.4, and 58.9 %, respectively. Comparing results of salvage PDR brachytherapy with or without simultaneous chemotherapy, the 10-year local control rates were 76 vs. 39 % (p= 0014), respectively. No other patient- or treatment-related parameters had a significant influence on treatment results. Soft tissue necrosis or bone necrosis developed in 18/104 (17.3 %) and 11/104 (9.6 %) patients, respectively, but only 3 % of patients required surgical treatment. PDR interstitial brachytherapy with simultaneous chemotherapy is a very effective and, in experienced hands, also a safe treatment modality in selected patients with head and neck cancer in previously irradiated areas. (orig.) [German] Es erfolgte die Analyse der Langzeitergebnisse einer protokollbasierten interstitiellen Brachytherapie (Re-Bestrahlung) mit simultaner Chemotherapie und interstitieller Hyperthermie

  19. Non-uniform dwell times in line source high dose rate brachytherapy: physical and radiobiological considerations

    International Nuclear Information System (INIS)

    Jones, B.; Tan, L.T.; Freestone, G.; Bleasdale, C.; Myint, S.; Littler, J.

    1994-01-01

    The ability to vary source dwell times in high dose rate (HDR) brachytherapy allows for the use of non-uniform dwell times along a line source. This may have advantages in the radical treatment of tumours depending on individual tumour geometry. This study investigates the potential improvements in local tumour control relative to adjacent normal tissue isoeffects when intratumour source dwell times are increased along the central portion of a line source (technique A) in radiotherapy schedules which include a relatively small component of HDR brachytherapy. Such a technique is predicted to increase the local control for tumours of diameters ranging between 2 cm and 4 cm by up to 11% compared with a technique in which there are uniform dwell times along the line source (technique B). There is no difference in the local control rates for the two techniques when used to treat smaller tumours. Normal tissue doses are also modified by the technique used. Technique A produces higher normal tissue doses at points perpendicular to the centre of the line source and lower dose at points nearer the ends of the line source if the prescription point is not in the central plane of the line source. Alternatively, if the dose is prescribed at a point in the central plane of the line source, the dose at all the normal tissue points are lower when technique A is used. (author)

  20. Fractionation in medium dose rate brachytherapy of cancer of the cervix

    International Nuclear Information System (INIS)

    Leborgne, Felix; Fowler, Jack F.; Leborgne, Jose H.; Zubizarreta, Eduardo; Chappell, Rick

    1996-01-01

    Purpose: To establish an optimum fractionation for medium dose rate (MDR) brachytherapy from retrospective data of patients treated with different MDR schedules in comparison with a low dose rate (LDR) schedule. Methods and Materials: The study population consists of consecutive Stage IB-IIA-IIB patients who received radiotherapy alone with full dose brachytherapy plus external beam pelvic and parametrial irradiation from 1986-1993. Patients also receiving surgery or chemotherapy were excluded. The LDR group (n = 102, median follow-up: 80 months) received a median dose to Point A of two 32.5 Gy fractions at 0.44 Gy/h plus 18 Gy of external whole pelvic irradiation. The MDR1 group (n = 30, median follow-up: 45 months) received a mean dose of two 32 Gy fractions at 1.68 Gy/h. An individual dose reduction of 12.5% was planned for this group according to the Manchester experience, but only a 4.8% dose reduction was achieved. The MDR2 group (n = 10, median follow-up: 36 months) received a dose of two 24 Gy fractions at 1.65 Gy/h. The MDR3 group (n = 10, median follow-up 33 months) received a mean dose of three 15.3 Gy fractions at 1.64 Gy/h. And finally, the MDR4 group (n = 38, median follow-up: 24 months) received six 7.7 Gy fractions from two pulses 6 h apart in each of three insertions at 1.61 Gy/h. The median external pelvic dose to MDR schedules was between 12 and 20 Gy. The linear quadratic (LQ) formula was used to calculate the biologically effective dose (BED) to tumor (Gy 10 ) and rectum (Gy 3 ), assuming T(1(2)) for repair = 1.5 h. Results: The crude central recurrence rate was 6% for LDR (mean BED = 95.4 Gy 10 ) and 10% for MDR4 (mean BED = 77.0 Gy 10 ) (p = NS). The remaining MDR groups had no recurrences. Grade 2 and 3 rectal or bladder complications were 0% for LDR (rectal BED = 109 Gy 3 ), 83% for MDR1 (BED = 206 Gy 3 ), and 30% for MDR3 (BED = 127 Gy 3 ). The MDR2 and MDR4 groups presented no complications (BED, 123 Gy 3 , and 105 Gy 3 , respectively

  1. Experiences of high dose rate interstitial brachytherapy for carcinoma of the mobile tongue

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Hiroshi; Inoue, Toshihiko; Yamazaki, Hideya (Osaka Univ. (Japan). Faculty of Medicine) (and others)

    1994-03-01

    Interstitial brachytherapy was conducted for mobile tongue carcinoma using a high dose rate remote afterloading machine with small [sup 192]I source. Detailed method, named as 'linked double-botton technique', is to approach from submandibular skin by an open-ended stainless steel needles to the tongue lesion, and to replace each needle into flexible nylon tube from the oral cavity. Delivered dose was 60 Gy/10 Fr./5-6 days at the distance 5 mm from the source plane. Ten patients with mobile tongue carcinoma Tl-2N0 were treated with this method from October 1991 through August 1992. Local was uncontrolled in one patient, in whom the lesion was combined with leukoplakia at both lateral borders of the tongue. This was in accordance with the result in low dose rate treatment. This can be a substitute to low dose rate system for treatment of mobile tongue carcinoma. (author).

  2. High-dose-rate afterloading brachytherapy in carcinoma of the cervix: an experience of 1992 patients

    International Nuclear Information System (INIS)

    Lorvidhaya, Vicharn; Tonusin, Anun; Changwiwit, Witit; Chitapanarux, Imjai; Srisomboon, Jatupol; Wanwilairat, Somsak; Chawapun, Nisa; Sukthomya, Vimol

    2000-01-01

    Purpose: To report the results of radiation therapy in carcinoma of the cervix treated by external irradiation and high-dose-rate (HDR) intracavitary brachytherapy. Methods and Materials: This is a retrospective analysis of 2063 patients with histologically proven carcinoma of the cervix treated by external irradiation and HDR intracavitary brachytherapy between March 1985-December 1991. The Kaplan-Meier method was used for survival and disease-free survival analysis. Late complications in the bowel and bladder were calculated actuarially. Results: There were 71 patients who did not complete the course of irradiation so only 1992 patients were retrospectively analyzed for survival. There were 2 patients (0.1%) in Stage IA, 211 (10.2%) Stage IB, 225 (10.9%) in Stage IIA, 902 (43.7%) in Stage IIB, 14 (0.7%) in Stage IIIA, 675 (32.7%) in Stage IIIB, 16 (0.8%) in Stage IVA, and 16 (0.8%) in Stage IVB. The median follow-up time was 96 months. The actuarial 5-year disease-free survival rate was 79.5%, 70.0%, 59.4%, 46.1%, 32.3%, 7.8%, and 23.1% for Stage IB, IIA, IIB, IIIA, IIIB, IVA, and IVB respectively. The actuarial 5-year disease-free survival rate for Stage IB 1 and IB 2 squamous cell carcinoma was 88.7% and 67.0%. The actuarial 5-year overall survival rate was 86.3%, 81.1%, 73.0%, 50.3%, 47.8%, 7.8%, and 30.8% for Stage IB, IIA, IIB, IIIA, IIIB, IVA, and IVB respectively. Pattern of failure revealed 20.8% local recurrence, 18.7% distant metastases, and 4% in both. The late complication rate Grade 3 and 4 (RTOG) for bowel and bladder combined was 7.0% with 1.9% Grade 4. Conclusion: HDR brachytherapy used in this series produced pelvic control and survival rates comparable to other LDR series

  3. Le Fort I osteotomy and low-dose rate Ir192 brachytherapy for treatment of recurrent nasopharyngeal tumours

    International Nuclear Information System (INIS)

    Hall, Charles E.J.; Harris, Robert; A'Hern, Roger; Archer, Daniel J.; Rhys-Evans, Peter; Henk, J. Michael; Harrington, Kevin J.; Nutting, Christopher M.

    2003-01-01

    Background: Treatment of recurrent nasopharyngeal carcinoma is a difficult clinical problem. External beam re-irradiation is associated with a long-term cure in a proportion of cases but this may be associated with severe radiation injury. Methods: Eighteen patients with post-nasal space tumours were treated between 1986 and 2001 with surgical excision and nasopharyngeal brachytherapy via a Le Fort I osteotomy approach. Low-dose rate (LDR) and high-dose rate (HDR) brachytherapy was used. Data was prospectively collected. Local control and overall survival were measured. Acute and late complications were assessed using the RTOG system. Results: The overall survival was 67% at 2 years and 33.5% at 5 years. The corresponding local control rates were 42 and 31.5%, respectively. The T stage at relapse was a significant prognostic factor for local control (P=0.004) but not overall survival. Acute toxicity was mild. RTOG grade ≥3 late complications occurred in 40% of patients treated with the HDR, and 0% treated with LDR. Conclusions: The results of the Le Fort osteotomy, tumour debulking and post-operative brachytherapy gives local control rates similar to those achieved with wide-field re-irradiation. Complication rates are acceptable and are lower than that reported with other methods of radiation therapy. The surgical technique was well tolerated. HDR brachytherapy with this technique had a high complication rate. This approach is a viable option in the treatment of recurrent nasopharyngeal tumours

  4. Perioperative Interstitial High-Dose-Rate Brachytherapy for the Treatment of Recurrent Keloids: Feasibility and Early Results

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Ping, E-mail: ping.jiang@uksh.de [Department of Radiation Oncology, University Clinic Schleswig-Holstein, Campus Kiel, Kiel (Germany); Baumann, René [Department of Radiation Oncology, University Clinic Schleswig-Holstein, Campus Kiel, Kiel (Germany); Dunst, Juergen [Department of Radiation Oncology, University Clinic Schleswig-Holstein, Campus Kiel, Kiel (Germany); Department of Radiation Oncology, University of Copenhagen, Copenhagen (Denmark); Geenen, Matthias [Department of Reconstructive Surgery, Lubinus Clinic Kiel, Kiel (Germany); Siebert, Frank-André [Department of Radiation Oncology, University Clinic Schleswig-Holstein, Campus Kiel, Kiel (Germany); Niehoff, Peter [Department of Radiation Oncology, University Clinic Schleswig-Holstein, Campus Kiel, Kiel (Germany); Department of Radiation Oncology, Community Clinic Köln, Köln (Germany); Department of Radiation Oncology, University Witten/Herdecke, Witten (Germany); Bertolini, Julia; Druecke, Daniel [Department of Reconstructive Surgery, University Clinic Schleswig-Holstein, Campus Kiel, Kiel (Germany)

    2016-03-01

    Purpose: To prospectively evaluate high-dose-rate brachytherapy in the treatment of therapy-resistant keloids and report first results, with emphasis on feasibility and early treatment outcome. Methods and Materials: From 2009 to 2014, 24 patients with 32 recurrent keloids were treated with immediate perioperative high-dose-rate brachytherapy; 3 patients had been previously treated with adjuvant external beam radiation therapy and presented with recurrences in the pretreated areas. Two or more different treatment modalities had been tried in all patients and had failed to achieve remission. After (re-)excision of the keloids, a single brachytherapy tube was placed subcutaneously before closing the wound. The target volume covered the scar in total length. Brachytherapy was given in 3 fractions with a single dose of 6 Gy in 5 mm tissue depth. The first fraction was given within 6 hours after surgery, the other 2 fractions on the first postoperative day. Thus, a total dose of 18 Gy in 3 fractions was administered within 36 hours after the resection. Results: The treatment was feasible in all patients. No procedure-related complications (eg, secondary infections) occurred. Nineteen patients had keloid-related symptoms before treatment like pain and pruritus; disappearance of symptoms was noticed in all patients after treatment. After a median follow-up of 29.4 months (range, 7.9-72.4 months), 2 keloid recurrences and 2 mildly hypertrophied scars were observed. The local control rate was 94%. Pigmentary abnormalities were detected in 3 patients, and an additional 6 patients had a mild delay in the wound-healing process. Conclusions: The early results of this study prove the feasibility and the efficacy of brachytherapy for the prevention of keloids. The results also suggest that brachytherapy may be advantageous in the management of high-risk keloids or as salvage treatment for failure after external beam therapy.

  5. Dosimetric perturbations of a lead shield for surface and interstitial high-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Candela-Juan, Cristian; Granero, Domingo; Vijande, Javier; Ballester, Facundo; Perez-Calatayud, Jose; Rivard, Mark J

    2014-01-01

    In surface and interstitial high-dose-rate brachytherapy with either 60 Co, 192 Ir, or 169 Yb sources, some radiosensitive organs near the surface may be exposed to high absorbed doses. This may be reduced by covering the implants with a lead shield on the body surface, which results in dosimetric perturbations. Monte Carlo simulations in Geant4 were performed for the three radionuclides placed at a single dwell position. Four different shield thicknesses (0, 3, 6, and 10 mm) and three different source depths (0, 5, and 10 mm) in water were considered, with the lead shield placed at the phantom surface. Backscatter dose enhancement and transmission data were obtained for the lead shields. Results were corrected to account for a realistic clinical case with multiple dwell positions. The range of the high backscatter dose enhancement in water is 3 mm for 60 Co and 1 mm for both 192 Ir and 169 Yb. Transmission data for 60 Co and 192 Ir are smaller than those reported by Papagiannis et al (2008 Med. Phys. 35 4898–4906) for brachytherapy facility shielding; for 169 Yb, the difference is negligible. In conclusion, the backscatter overdose produced by the lead shield can be avoided by just adding a few millimetres of bolus. Transmission data provided in this work as a function of lead thickness can be used to estimate healthy organ equivalent dose saving. Use of a lead shield is justified. (paper)

  6. Pilot Quality Control Program for Brachytherapy of Low Dose Rate at the General Hospital of Mexico

    Science.gov (United States)

    Álvarez R., J. T.; Tovar M., V.; Salinas, B.; Hernández O., O.; Santillán B., L.; Molero M., C.; Montoya M., J.

    2004-09-01

    We describe the pilot quality control program for brachytherapy of low dose rate proposed to be used in the Radiotherapy Department at the General Hospital of Mexico. The program consists of three parts: a) development of calibration procedures, performed in terms of air-kerma strength for calibration of 137Cs and 192Ir brachytherapy sources, and for the calibration of well-type ionization chambers for 137Cs, b) performance of localisation and reconstruction techniques for radioactive sources with a Baltas' phantom. The results obtained for the media deviation , are in the optimum level, ± 0.5 mm hospital. It consists on the characterisation of a TLD-100 powder dosimetry system at SSDL: The calibration curves for powder response (nC or nC/ mg) vs Dw and the control charts for the Harshaw 3500 reader were obtained. The statistical validation of the calibration curve by normality of the residuals and the lack of fit tests were realised. In the other hand, TLD's were irradiated in the hospital to a nominal Dw = 2 Gy with sources of 137Cs. The percent deviations Δ%, between the Dw imparted by the Hospital and the determined by SSDL, are 1.2% Δ⩽ 6.5 % which are consistent with the expanded uncertainty U% for DW, 5.6 U% 10%.

  7. Pilot Quality Control Program for Brachytherapy of Low Dose Rate at the General Hospital of Mexico

    International Nuclear Information System (INIS)

    Alvarez R, J.T.; Tovar M, V.; Salinas, B.; Hernandez O, O.; Santillan B, L.; Molero M, C.; Montoya M, J.

    2004-01-01

    We describe the pilot quality control program for brachytherapy of low dose rate proposed to be used in the Radiotherapy Department at the General Hospital of Mexico. The program consists of three parts: a) development of calibration procedures, performed in terms of air-kerma strength for calibration of 137Cs and 192Ir brachytherapy sources, and for the calibration of well-type ionization chambers for 137Cs, b) performance of localisation and reconstruction techniques for radioactive sources with a Baltas' phantom. The results obtained for the media deviation , are in the optimum level, ± 0.5 mm < ± 1.0 mm; the confidence limit Δ, is in the emergency level, Δ=3.2 mm. c) verification of absorbed dose to water DW, given by the hospital. It consists on the characterisation of a TLD-100 powder dosimetry system at SSDL: The calibration curves for powder response (nC or nC/ mg) vs Dw and the control charts for the Harshaw 3500 reader were obtained. The statistical validation of the calibration curve by normality of the residuals and the lack of fit tests were realised. In the other hand, TLD's were irradiated in the hospital to a nominal Dw = 2 Gy with sources of 137Cs. The percent deviations Δ%, between the Dw imparted by the Hospital and the determined by SSDL, are 1.2% Δ≤ 6.5 % which are consistent with the expanded uncertainty U% for DW, 5.6 U% 10%

  8. Photon spectrometry for the determination of the dose-rate constant of low-energy photon-emitting brachytherapy sources

    International Nuclear Information System (INIS)

    Chen, Zhe Jay; Nath, Ravinder

    2007-01-01

    Accurate determination of dose-rate constant (Λ) for interstitial brachytherapy sources emitting low-energy photons (<50 keV) has remained a challenge in radiation dosimetry because of the lack of a suitable absolute dosimeter for accurate measurement of the dose rates near these sources. Indeed, a consensus value of Λ taken as the arithmetic mean of the dose-rate constants determined by different research groups and dosimetry techniques has to be used at present for each source model in order to minimize the uncertainties associated with individual determinations of Λ. Because the dosimetric properties of a source are fundamentally determined by the characteristics of the photons emitted by the source, a new technique based on photon spectrometry was developed in this work for the determination of dose-rate constant. The photon spectrometry technique utilized a high-resolution gamma-ray spectrometer to measure source-specific photon characteristics emitted by the low-energy sources and determine their dose-rate constants based on the measured photon-energy spectra and known dose-deposition properties of mono-energetic photons in water. This technique eliminates many of the difficulties arising from detector size, the energy dependence of detector sensitivity, and the use of non-water-equivalent solid phantoms in absolute dose rate measurements. It also circumvents the uncertainties that might be associated with the source modeling in Monte Carlo simulation techniques. It was shown that the estimated overall uncertainty of the photon spectrometry technique was less than 4%, which is significantly smaller than the reported 8-10% uncertainty associated with the current thermo-luminescent dosimetry technique. In addition, the photon spectrometry technique was found to be stable and quick in Λ determination after initial setup and calibration. A dose-rate constant can be determined in less than two hours for each source. These features make it ideal to determine

  9. Applicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film

    Directory of Open Access Journals (Sweden)

    Seyed Mohsen Hosseini Daghigh

    2012-03-01

    Full Text Available Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phantom was built in order to be inserted by various sizes of esophageal applicators. EDR2 films were placed at 33 mm from Ir-192 source and irradiated with 1.5 Gy after planning using treatment planning system for all applicators. Results The results of film dosimetry in reference point for 6, 8, 10, and 20 mm applicators were 1.54, 1.53, 1.48, and 1.50 Gy, respectively. The difference between practical and treatment planning system results was 0.023 Gy (

  10. Quality control in pulsed dose rate brachytherapy; Controle de qualite en curietherapie de debit de dose pulse

    Energy Technology Data Exchange (ETDEWEB)

    Metayer, Y.; Brunaud, C.; Peiffert, D. [Centre Alexis-Vautrin, Unite de Radiophysique, 54 - Vandoeuvre-les-Nancy (France); Meyer, P. [Centre Paul-Strauss, 67 - Strasbourg (France)

    2009-07-15

    A prospective multicenter study (P.D.R.) was leaded on pulsed dose rate brachytherapy over 2 years (2005/2006) in 20 French centres, as part of a programme entitled (Support for the innovative and expensive techniques) S.t.i.c.-P.D.R. and supported by the French ministry of health. Eight hundred and fifty patients were treated for cervix carcinoma with 2D classic or 3D innovative brachytherapy (425 in each arm). The main objectives of this study were to assess the cost of P.D.R. brachytherapy with dose optimization compared to traditional treatments, and to evaluate the complications and local control. A joint programme of quality control was established by the physicists of the different centres, concerning the software treatment planning, the source replacement, the projector and the technical parameters of the course of patient treatment. This technical note lists these controls, and their frequency. (authors)

  11. Medically inoperable endometrial cancer in patients with a high body mass index (BMI): Patterns of failure after 3-D image-based high dose rate (HDR) brachytherapy

    DEFF Research Database (Denmark)

    Acharya, Sahaja; Esthappan, Jacqueline; Badiyan, Shahed

    2016-01-01

    the patterns of failure after definitive treatment with 3-D image-based high dose rate (HDR) brachytherapy for medically inoperable endometrial cancer. MATERIALS AND METHODS: Forty-three consecutive patients with endometrial cancer FIGO stages I-III were treated definitively with HDR brachytherapy...

  12. High dose rate brachytherapy in patients with local recurrences after radiotherapy of non-small cell lung cancer

    NARCIS (Netherlands)

    Sutedja, G.; Baris, G.; Schaake-Koning, C.; van Zandwijk, N.

    1992-01-01

    Thirty-one patients with recurrences of locally advanced Stage III lung cancer were treated with high dose rate brachytherapy. All patients had previously received a full course external beam irradiation. All treatments were performed under topical anaesthesia and took 6-14 min depending on the

  13. Advantages of high-dose rate (HDR) brachytherapy in treatment of prostate cancer

    Science.gov (United States)

    Molokov, A. A.; Vanina, E. A.; Tseluyko, S. S.

    2017-09-01

    One of the modern methods of preserving organs radiation treatment is brachytherapy. This article analyzes the results of prostate brachytherapy. These studies of the advantages of high dose brachytherapy lead to the conclusion that this method of radiation treatment for prostate cancer has a favorable advantage in comparison with remote sensing methods, and is competitive, preserving organs in comparison to surgical methods of treatment. The use of the method of polyfocal transperineal biopsy during the brachytherapy session provides information on the volumetric spread of prostate cancer and adjust the dosimetry plan taking into account the obtained data.

  14. Inverse Planned High-Dose-Rate Brachytherapy for Locoregionally Advanced Cervical Cancer: 4-Year Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Tinkle, Christopher L.; Weinberg, Vivian [Department of Radiation Oncology, University of California, San Francisco, California (United States); Chen, Lee-May [Department of Obstetrics, Gynecology, and Reproductive Sciences, University of California, San Francisco, California (United States); Littell, Ramey [Gynecologic Oncology, The Permanente Medical Group, San Francisco, California (United States); Cunha, J. Adam M.; Sethi, Rajni A. [Department of Radiation Oncology, University of California, San Francisco, California (United States); Chan, John K. [Gynecologic Oncology, California Pacific Medical Center, San Francisco, California (United States); Hsu, I-Chow, E-mail: ichow.hsu@ucsf.edu [Department of Radiation Oncology, University of California, San Francisco, California (United States)

    2015-08-01

    Purpose: Evaluate the efficacy and toxicity of image guided brachytherapy using inverse planning simulated annealing (IPSA) high-dose-rate brachytherapy (HDRB) boost for locoregionally advanced cervical cancer. Methods and Materials: From December 2003 through September 2009, 111 patients with primary cervical cancer were treated definitively with IPSA-planned HDRB boost (28 Gy in 4 fractions) after external radiation at our institution. We performed a retrospective review of our experience using image guided brachytherapy. Of the patients, 70% had a tumor size >4 cm, 38% had regional nodal disease, and 15% had clinically evident distant metastasis, including nonregional nodal disease, at the time of diagnosis. Surgical staging involving pelvic lymph node dissection was performed in 15% of patients, and 93% received concurrent cisplatin-based chemotherapy. Toxicities are reported according to the Common Terminology Criteria for Adverse Events version 4.0 guidelines. Results: With a median follow-up time of 42 months (range, 3-84 months), no acute or late toxicities of grade 4 or higher were observed, and grade 3 toxicities (both acute and late) developed in 8 patients (1 constitutional, 1 hematologic, 2 genitourinary, 4 gastrointestinal). The 4-year Kaplan-Meier estimate of late grade 3 toxicity was 8%. Local recurrence developed in 5 patients (4 to 9 months after HDRB), regional recurrence in 3 (6, 16, and 72 months after HDRB), and locoregional recurrence in 1 (4 months after HDR boost). The 4-year estimates of local, locoregional, and distant control of disease were 94.0%, 91.9%, and 69.1%, respectively. The overall and disease-free survival rates at 4 years were 64.3% (95% confidence interval [CI] of 54%-73%) and 61.0% (95% CI, 51%-70%), respectively. Conclusions: Definitive radiation by use of inverse planned HDRB boost for locoregionally advanced cervical cancer is well tolerated and achieves excellent local control of disease. However, overall

  15. Limitations of the TG-43 formalism for skin high-dose-rate brachytherapy dose calculations

    Energy Technology Data Exchange (ETDEWEB)

    Granero, Domingo, E-mail: dgranero@eresa.com [Department of Radiation Physics, ERESA, Hospital General Universitario, 46014 Valencia (Spain); Perez-Calatayud, Jose [Radiotherapy Department, La Fe University and Polytechnic Hospital, Valencia 46026 (Spain); Vijande, Javier [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100, Spain and IFIC (UV-CSIC), Paterna 46980 (Spain); Ballester, Facundo [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Rivard, Mark J. [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States)

    2014-02-15

    Purpose: In skin high-dose-rate (HDR) brachytherapy, sources are located outside, in contact with, or implanted at some depth below the skin surface. Most treatment planning systems use the TG-43 formalism, which is based on single-source dose superposition within an infinite water medium without accounting for the true geometry in which conditions for scattered radiation are altered by the presence of air. The purpose of this study is to evaluate the dosimetric limitations of the TG-43 formalism in HDR skin brachytherapy and the potential clinical impact. Methods: Dose rate distributions of typical configurations used in skin brachytherapy were obtained: a 5 cm × 5 cm superficial mould; a source inside a catheter located at the skin surface with and without backscatter bolus; and a typical interstitial implant consisting of an HDR source in a catheter located at a depth of 0.5 cm. Commercially available HDR{sup 60}Co and {sup 192}Ir sources and a hypothetical {sup 169}Yb source were considered. The Geant4 Monte Carlo radiation transport code was used to estimate dose rate distributions for the configurations considered. These results were then compared to those obtained with the TG-43 dose calculation formalism. In particular, the influence of adding bolus material over the implant was studied. Results: For a 5 cm × 5 cm{sup 192}Ir superficial mould and 0.5 cm prescription depth, dose differences in comparison to the TG-43 method were about −3%. When the source was positioned at the skin surface, dose differences were smaller than −1% for {sup 60}Co and {sup 192}Ir, yet −3% for {sup 169}Yb. For the interstitial implant, dose differences at the skin surface were −7% for {sup 60}Co, −0.6% for {sup 192}Ir, and −2.5% for {sup 169}Yb. Conclusions: This study indicates the following: (i) for the superficial mould, no bolus is needed; (ii) when the source is in contact with the skin surface, no bolus is needed for either {sup 60}Co and {sup 192}Ir. For

  16. Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Poulin, Eric; Fekete, Charles-Antoine Collins; Beaulieu, Luc; Létourneau, Mélanie; Fenster, Aaron; Pouliot, Jean

    2013-01-01

    Purpose: An innovative, simple, and fast method to optimize the number and position of catheters is presented for prostate and breast high dose rate (HDR) brachytherapy, both for arbitrary templates or template-free implants (such as robotic templates).Methods: Eight clinical cases were chosen randomly from a bank of patients, previously treated in our clinic to test our method. The 2D Centroidal Voronoi Tessellations (CVT) algorithm was adapted to distribute catheters uniformly in space, within the maximum external contour of the planning target volume. The catheters optimization procedure includes the inverse planning simulated annealing algorithm (IPSA). Complete treatment plans can then be generated from the algorithm for different number of catheters. The best plan is chosen from different dosimetry criteria and will automatically provide the number of catheters and their positions. After the CVT algorithm parameters were optimized for speed and dosimetric results, it was validated against prostate clinical cases, using clinically relevant dose parameters. The robustness to implantation error was also evaluated. Finally, the efficiency of the method was tested in breast interstitial HDR brachytherapy cases.Results: The effect of the number and locations of the catheters on prostate cancer patients was studied. Treatment plans with a better or equivalent dose distributions could be obtained with fewer catheters. A better or equal prostate V100 was obtained down to 12 catheters. Plans with nine or less catheters would not be clinically acceptable in terms of prostate V100 and D90. Implantation errors up to 3 mm were acceptable since no statistical difference was found when compared to 0 mm error (p > 0.05). No significant difference in dosimetric indices was observed for the different combination of parameters within the CVT algorithm. A linear relation was found between the number of random points and the optimization time of the CVT algorithm. Because the

  17. Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Poulin, Eric; Fekete, Charles-Antoine Collins; Beaulieu, Luc [Département de Physique, de Génie Physique et d’Optique et Centre de recherche sur le cancer de l’Université Laval, Université Laval, Québec, Québec G1V 0A6, Canada and Département de Radio-Oncologie et Axe oncologie du Centre de Recherche du CHU de Québec, CHU de Québec, 11 Côte du Palais, Québec, Québec G1R 2J6 (Canada); Létourneau, Mélanie [Département de Radio-Oncologie, CHU de Québec, 11 Côte du Palais, Québec, Québec G1R 2J6 (Canada); Fenster, Aaron [Imaging Research Laboratories, Robarts Research Institute, 100 Perth Drive, London, Ontario N6A 5K8 (United Kingdom); Pouliot, Jean [Department of Radiation Oncology, University of California San Francisco, Helen Diller Family Comprehensive Cancer Center, 1600 Divisadero Street, San Francisco, California 94143-1708 (United States)

    2013-11-15

    Purpose: An innovative, simple, and fast method to optimize the number and position of catheters is presented for prostate and breast high dose rate (HDR) brachytherapy, both for arbitrary templates or template-free implants (such as robotic templates).Methods: Eight clinical cases were chosen randomly from a bank of patients, previously treated in our clinic to test our method. The 2D Centroidal Voronoi Tessellations (CVT) algorithm was adapted to distribute catheters uniformly in space, within the maximum external contour of the planning target volume. The catheters optimization procedure includes the inverse planning simulated annealing algorithm (IPSA). Complete treatment plans can then be generated from the algorithm for different number of catheters. The best plan is chosen from different dosimetry criteria and will automatically provide the number of catheters and their positions. After the CVT algorithm parameters were optimized for speed and dosimetric results, it was validated against prostate clinical cases, using clinically relevant dose parameters. The robustness to implantation error was also evaluated. Finally, the efficiency of the method was tested in breast interstitial HDR brachytherapy cases.Results: The effect of the number and locations of the catheters on prostate cancer patients was studied. Treatment plans with a better or equivalent dose distributions could be obtained with fewer catheters. A better or equal prostate V100 was obtained down to 12 catheters. Plans with nine or less catheters would not be clinically acceptable in terms of prostate V100 and D90. Implantation errors up to 3 mm were acceptable since no statistical difference was found when compared to 0 mm error (p > 0.05). No significant difference in dosimetric indices was observed for the different combination of parameters within the CVT algorithm. A linear relation was found between the number of random points and the optimization time of the CVT algorithm. Because the

  18. Analysis of the high dose rate brachytherapy protocols of quality assurance programs of some local services, based on T G 40, T G 56 and ARCAL 30

    International Nuclear Information System (INIS)

    Guzman Calcina, Carmen S.; Almeida, Adelaide de; Rocha, Jose R. Oliveira; Universidade Estadual de Campinas, SP

    2001-01-01

    High dose rate brachytherapy has been increasingly recognized in most countries, and radiotherapy services using this equipment are encouraged to have a very efficient quality assurance program to ensure protection for patients, workers and other personnel involved. The objective of this paper was to determine the types of tests for high dose rate equipment required by official protocols (TG 40, TG 56 and ARCAL XXX) and to compare them with the types of tests utilized by some radiotherapy services. We concluded that: the protocol TG 56 is more extensive and complete than the other official protocols (T G 40 and ARCAL XXX); the protocols used by the services evaluated on this study were based on the protocol TG 56, and were concordant with the other official protocols. In these protocols annual tests were frequently replaced by tests performed quarterly or twice a year. This study established the types of test used and their frequency of utilization, and permitted the design of an optimized protocol that may help in the implementation of basic and indispensable tests in order to ensure patient adequate treatment and safety to personnel involved, and consequently improve high dose rate brachytherapy quality assurance. (author)

  19. Post-operative high dose rate vaginal apex brachytherapy in stage I endometrial adenocarcinoma

    International Nuclear Information System (INIS)

    Gumbs, A.A.; Turner, B.C.; Knisely, J.P.S.; Kacinski, B.M.; Roberts, K.B.; Peschel, R.E.; Haffty, B.G.; Rutherford, T.J.; Edraki, B.; Schwartz, P.E.; Wilson, L.D.

    1996-01-01

    Purpose/Objective: Patients with Stage I endometrial adenocarcinoma have traditionally been treated with total abdominal hysterectomy/bilateral salpingo-oophorectomy and radiation. The reported incidence of local recurrence in surgically treated patients with FIGO Stage IA or IB endometrial adenocarcinoma is 4-10% at 2 years. Combined surgery and radiation has resulted in a reduction of recurrence to 2-6%. We report the presentation, actuarial survival, actuarial rate of local failure, salvage rate, and complications for patients undergoing high dose rate (HDR) vaginal apex brachytherapy following surgery. Materials and Methods: Between 1985 and 1994 a total of 286 patients with FIGO Stage I endometrioid uterine adenocarcinoma were treated with HDR Ir-192 vaginal apex brachytherapy alone to a total dose of 21 Gy in 3 fractions at 0.5 cm from the vaginal mucosa. The pathologic stage by treatment group was IA: 31%, IB: 68%, and IC: 1%. The histologic grade of the patient's tumors was grade 1: 69%, 2: 29%, and 3: 2% of patients. The median time from surgery to radiation was 34 days (range 14-66 days). The median follow-up for 286 patients with Stage IA (92 patients), IB (190 patients), and IC (4 patients) was respectively, 37, 35 and 40 months (2 patients lost to follow-up prior to 6 months). Results: Patients presented with vaginal bleeding (94%) or abnormal pap smear (6%) at a median age for Stage IA and IB, of 54 and 63 years, respectively (range 32-88). The 5-year overall actuarial survival rate was 94.5%. The 5-year actuarial survival rate by histologic grade was 97.5% and 91.5% for FIGO grade 1 and 2, respectively (p=.011). The 5-year actuarial survival rate by depth of myometrial invasion was 99.0% and 92.5% for Stage IA and IB, respectively (p=.029). Median overall time to failure is 19.5 months (range 10-36 months). The 5-year actuarial rate of local failure was 4.5%. The overall failure rate in our study group was 2.8% (8 patients), local failure only 1

  20. COMP report: CPQR technical quality control guidelines for low-dose-rate permanent seed brachytherapy.

    Science.gov (United States)

    Beaulieu, Luc; Radford, Dee-Ann; Eduardo Villarreal-Barajas, J

    2018-03-14

    The Canadian Organization of Medical Physicists (COMP), in close partnership with the Canadian Partnership for Quality Radiotherapy (CPQR) has developed a series of Technical Quality Control (TQC) guidelines for radiation treatment equipment. These guidelines outline the performance objectives that equipment should meet in order to ensure an acceptable level of radiation treatment quality. The TQC guidelines have been rigorously reviewed and field tested in a variety of Canadian radiation treatment facilities. The development process enables rapid review and update to keep the guidelines current with changes in technology. This article contains detailed performance objectives and safety criteria for low-dose-rate (LDR) permanent seed brachytherapy. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  1. Pulsed-dose-rate and low-dose-rate brachytherapy : Comparison of sparing effects in cells of a radiosensitive and a radioresistant cell line

    NARCIS (Netherlands)

    Pomp, J; Woudstra, EC; Kampinga, HH

    Pulsed-dose-rate regimens are an attractive alternative to continuous low-dose-rate brachytherapy. However, apart from data obtained from modeling, only a few irt vitro results are available for comparing the biological effectiveness of both modalities. Cells of two human cell lines with survival

  2. Comparison BIPM.RI(I)-K8 of high dose-rate Ir-192 brachytherapy standards for reference air kerma rate of the VSL and the BIPM

    DEFF Research Database (Denmark)

    Alvarez, J.T.; De Pooter, J.A.; Andersen, Claus E.

    2014-01-01

    An indirect comparison of the standards for reference air kerma rate for 192Ir high dose rate brachytherapy sources of the Dutch Metrology Institute (VSL), The Netherlands, and of the Bureau International des Poids et Mesures (BIPM) was carried out at the VSL in November 2009. The comparison resu...

  3. Implementation of microsource high dose rate (mHDR) brachytherapy in developing countries

    International Nuclear Information System (INIS)

    2001-11-01

    Brachytherapy using remote afterloading of a single high dose rate 192 Ir microsource was developed in the 1970s. After its introduction to clinics, this system has spread rapidly among developed Member States and has become a highly desirable modality in cancer treatment. This technique is now gradually being introduced to the developing Member States. The 192 Ir sources are produced with a high specific activity. This results in a high dose rate (HDR) to the tumour and shorter treatment times. The high specific activity simultaneously results in a much smaller source (so-called micro source, around I mm in diameter) which may be easily inserted into tissue through a thin delivery tube, the so-called interstitial treatment, as well as easily inserted into body cavities, the so-called intracavitary or endoluminal treatment. Another advantage is the ability to change dwell time (the time a source remains in one position) of the stepping source which allows dose distribution to match the target volume more closely. The purpose of this TECDOC is to advise radiation oncologists, medical physicists and hospital administrators in hospitals which are planning to introduce 192 Ir microsource HDR (mHDR) remote afterloading systems. The document supplements IAEA-TECDOC-1040, Design and Implementation of a Radiotherapy Programme: Clinical, Medical Physics, Radiation Protection and Safety Aspects, and will facilitate implementation of this new brachytherapy technology, especially in developing countries. The operation of the system, 'how to use the system', is not within the scope of this document. This TECDOC is based on the recommendations of an Advisory Group meeting held in Vienna in April 1999

  4. Online pretreatment verification of high-dose rate brachytherapy using an imaging panel.

    Science.gov (United States)

    Fonseca, Gabriel P; Podesta, Mark; Bellezzo, Murillo; Van den Bosch, Michiel R; Lutgens, Ludy; Vanneste, Ben G L; Voncken, Robert; Van Limbergen, Evert J; Reniers, Brigitte; Verhaegen, Frank

    2017-07-07

    Brachytherapy is employed to treat a wide variety of cancers. However, an accurate treatment verification method is currently not available. This study describes a pre-treatment verification system that uses an imaging panel (IP) to verify important aspects of the treatment plan. A detailed modelling of the IP was only possible with an extensive calibration performed using a robotic arm. Irradiations were performed with a high dose rate (HDR) 192 Ir source within a water phantom. An empirical fit was applied to measure the distance between the source and the detector so 3D Cartesian coordinates of the dwell positions can be obtained using a single panel. The IP acquires 7.14 fps to verify the dwell times, dwell positions and air kerma strength (Sk). A gynecological applicator was used to create a treatment plan that was registered with a CT image of the water phantom used during the experiments for verification purposes. Errors (shifts, exchanged connections and wrong dwell times) were simulated to verify the proposed verification system. Cartesian source positions (panel measurement plane) have a standard deviation of about 0.02 cm. The measured distance between the source and the panel (z-coordinate) have a standard deviation up to 0.16 cm and maximum absolute error of  ≈0.6 cm if the signal is close to sensitive limit of the panel. The average response of the panel is very linear with Sk. Therefore, Sk measurements can be performed with relatively small errors. The measured dwell times show a maximum error of 0.2 s which is consistent with the acquisition rate of the panel. All simulated errors were clearly identified by the proposed system. The use of IPs is not common in brachytherapy, however, it provides considerable advantages. It was demonstrated that the IP can accurately measure Sk, dwell times and dwell positions.

  5. Real-time inverse high-dose-rate brachytherapy planning with catheter optimization by compressed sensing-inspired optimization strategies.

    Science.gov (United States)

    Guthier, C V; Aschenbrenner, K P; Müller, R; Polster, L; Cormack, R A; Hesser, J W

    2016-08-21

    This paper demonstrates that optimization strategies derived from the field of compressed sensing (CS) improve computational performance in inverse treatment planning (ITP) for high-dose-rate (HDR) brachytherapy. Following an approach applied to low-dose-rate brachytherapy, we developed a reformulation of the ITP problem with the same mathematical structure as standard CS problems. Two greedy methods, derived from hard thresholding and subspace pursuit are presented and their performance is compared to state-of-the-art ITP solvers. Applied to clinical prostate brachytherapy plans speed-up by a factor of 56-350 compared to state-of-the-art methods. Based on a Wilcoxon signed rank-test the novel method statistically significantly decreases the final objective function value (p  optimization times were below one second and thus planing can be considered as real-time capable. The novel CS inspired strategy enables real-time ITP for HDR brachytherapy including catheter optimization. The generated plans are either clinically equivalent or show a better performance with respect to dosimetric measures.

  6. American Society for Radiation Oncology (ASTRO) and American College of Radiology (ACR) practice guideline for the performance of high-dose-rate brachytherapy.

    Science.gov (United States)

    Erickson, Beth A; Demanes, D Jeffrey; Ibbott, Geoffrey S; Hayes, John K; Hsu, I-Chow J; Morris, David E; Rabinovitch, Rachel A; Tward, Jonathan D; Rosenthal, Seth A

    2011-03-01

    High-Dose-Rate (HDR) brachytherapy is a safe and efficacious treatment option for patients with a variety of different malignancies. Careful adherence to established standards has been shown to improve the likelihood of procedural success and reduce the incidence of treatment-related morbidity. A collaborative effort of the American College of Radiology (ACR) and American Society for Therapeutic Radiation Oncology (ASTRO) has produced a practice guideline for HDR brachytherapy. The guideline defines the qualifications and responsibilities of all the involved personnel, including the radiation oncologist, physicist and dosimetrists. Review of the leading indications for HDR brachytherapy in the management of gynecologic, thoracic, gastrointestinal, breast, urologic, head and neck, and soft tissue tumors is presented. Logistics with respect to the brachytherapy implant procedures and attention to radiation safety procedures and documentation are presented. Adherence to these practice guidelines can be part of ensuring quality and safety in a successful HDR brachytherapy program. Copyright © 2011. Published by Elsevier Inc.

  7. Radioablation of adrenal gland malignomas with interstitial high-dose-rate brachytherapy. Efficacy and outcome

    Energy Technology Data Exchange (ETDEWEB)

    Mohnike, K. [Universitaetsklinikum Magdeburg A.oe.R., Otto-von-Guericke-Universitaet, Klinik fuer Radiologie und Nuklearmedizin, Magdeburg (Germany); DTZ am Frankfurter Tor, Berlin (Germany); Neumann, K.; Seidensticker, M.; Seidensticker, R.; Pech, M.; Streitparth, T.; Ricke, J. [Universitaetsklinikum Magdeburg A.oe.R., Otto-von-Guericke-Universitaet, Klinik fuer Radiologie und Nuklearmedizin, Magdeburg (Germany); Hass, P.; Gademann, G. [Universitaetsklinikum Magdeburg A.oe.R., Otto-von-Guericke-Universitaet, Klinik fuer Strahlentherapie, Magdeburg (Germany); Klose, S. [Universitaetsklinikum Magdeburg A.oe.R., Otto-von-Guericke-Universitaet, Klinik fuer Nieren- und Hochdruckkrankheiten, Diabetologie und Endokrinologie, Magdeburg (Germany); Garlipp, B.; Benckert, C. [Universitaetsklinikum Magdeburg A.oe.R., Otto-von-Guericke-Universitaet, Klinik fuer Allgemein-, Viszeral- und Gefaesschirurgie, Magdeburg (Germany); Wendler, J.J.; Liehr, U.B.; Schostak, M. [Universitaetsklinikum Magdeburg A.oe.R., Otto-von-Guericke-Universitaet, Klinik fuer Urologie und Kinderurologie, Magdeburg (Germany); Goeppner, D. [Universitaetsklinikum Magdeburg A.oe.R., Otto-von-Guericke-Universitaet, Klinik fuer Dermatologie, Magdeburg (Germany)

    2017-08-15

    To assess the efficacy, safety, and outcome of image-guided high-dose-rate (HDR) brachytherapy in patients with adrenal gland metastases (AGM). From January 2007 to April 2014, 37 patients (7 female, 30 male; mean age 66.8 years, range 41.5-82.5 years) with AGM from different primary tumors were treated with CT-guided HDR interstitial brachytherapy (iBT). Primary endpoint was local tumor control (LTC). Secondary endpoints were time to untreatable progression (TTUP), time to progression (TTP), overall survival (OS), and safety. In a secondary analysis, risk factors with an influence on survival were identified. The median biological equivalent dose (BED) was 37.4 Gy. Mean LTC after 12 months was 88%; after 24 months this was 74%. According to CTCAE criteria, one grade 3 adverse event occurred. Median OS after first diagnosis of AGM was 18.3 months. Median OS, TTUP, and TTP after iBT treatment were 11.4, 6.6, and 3.5 months, respectively. Uni- and multivariate Cox regression analyses revealed significant influences of synchronous disease, tumor diameter, and the total number of lesions on OS or TTUP or both. Image-guided HDR-iBT is safe and effective. Treatment- and primary tumor-independent features influenced survival of patients with AGM after HDR-iBR treatment. (orig.) [German] Beurteilung der Effektivitaet, Sicherheit und Ergebnisse nach bildgefuehrter High-dose-rate-(HDR-)Brachytherapie bei Patienten mit Nebennierenmetastasen. Von Januar 2007 bis April 2014 wurden 37 Patienten (7 weiblich, 30 maennlich; mittleres Alter 66,8 Jahre, Spanne 41,5-82,5 Jahre) mit Nebennierenmetastasen verschiedener Primarien mit CT-gesteuerter interstitieller HDR-Brachytherapie (iBT) behandelt. Der primaere Endpunkt war die lokale Tumorkontrolle (LTC). Sekundaere Endpunkte umfassten die Zeit bis zum nicht mehr behandelbaren Progress (TTUP), die Zeit bis zum Progress (TTP), das Gesamtueberleben (OS) und die Sicherheit der Methode. In einer sekundaeren Analyse wurden Risikofaktoren

  8. Automated high-dose rate brachytherapy treatment planning for a single-channel vaginal cylinder applicator

    Science.gov (United States)

    Zhou, Yuhong; Klages, Peter; Tan, Jun; Chi, Yujie; Stojadinovic, Strahinja; Yang, Ming; Hrycushko, Brian; Medin, Paul; Pompos, Arnold; Jiang, Steve; Albuquerque, Kevin; Jia, Xun

    2017-06-01

    High dose rate (HDR) brachytherapy treatment planning is conventionally performed manually and/or with aids of preplanned templates. In general, the standard of care would be elevated by conducting an automated process to improve treatment planning efficiency, eliminate human error, and reduce plan quality variations. Thus, our group is developing AutoBrachy, an automated HDR brachytherapy planning suite of modules used to augment a clinical treatment planning system. This paper describes our proof-of-concept module for vaginal cylinder HDR planning that has been fully developed. After a patient CT scan is acquired, the cylinder applicator is automatically segmented using image-processing techniques. The target CTV is generated based on physician-specified treatment depth and length. Locations of the dose calculation point, apex point and vaginal surface point, as well as the central applicator channel coordinates, and the corresponding dwell positions are determined according to their geometric relationship with the applicator and written to a structure file. Dwell times are computed through iterative quadratic optimization techniques. The planning information is then transferred to the treatment planning system through a DICOM-RT interface. The entire process was tested for nine patients. The AutoBrachy cylindrical applicator module was able to generate treatment plans for these cases with clinical grade quality. Computation times varied between 1 and 3 min on an Intel Xeon CPU E3-1226 v3 processor. All geometric components in the automated treatment plans were generated accurately. The applicator channel tip positions agreed with the manually identified positions with submillimeter deviations and the channel orientations between the plans agreed within less than 1 degree. The automatically generated plans obtained clinically acceptable quality.

  9. Low-dose-rate brachytherapy for patients with transurethral resection before implantation in prostate cancer: long-term results

    Energy Technology Data Exchange (ETDEWEB)

    Prada, Pedro J.; Anchuelo, Javier; Blanco, Ana Garcia; Paya, Gema; Cardenal, Juan; Acuña, Enrique; Ferri, Maria [Department of Radiation Oncology, Hospital Universitario Marqués de Valdecilla, Santander, Cantabria (Spain); Vazquez, Andres; Pacheco, Maite; Sanchez, Jesica [Department of Radiation Physics, Hospital Universitario Marqués de Valdecilla, Santander, Cantabria (Spain)

    2016-01-15

    Objectives: We analyzed the long-term oncologic outcome for patients with prostate cancer and transurethral resection who were treated using low-dose-rate (LDR) prostate brachytherapy. Methods and Materials: From January 2001 to December 2005, 57 consecutive patients were treated with clinically localized prostate cancer. No patients received external beam radiation. All of them underwent LDR prostate brachytherapy. Biochemical failure was defined according to the 'Phoenix consensus'. Patients were stratified as low and intermediate risk based on The Memorial Sloan Kettering group definition. Results: The median follow-up time for these 57 patients was 104 months. The overall survival according to Kaplan-Meier estimates was 88% (±6%) at 5 years and 77% (±6%) at 12 years. The 5 and 10 years for failure in tumour-free survival (TFS) was 96% and respectively (±2%), whereas for biochemical control was 94% and respectively (±3%) at 5 and 10 years, 98% (±1%) of patients being free of local recurrence. A patient reported incontinence after treatment (1.7%). The chronic genitourinary complains grade I were 7% and grade II, 10%. At six months 94% of patients reported no change in bowel function. Conclusions: The excellent long-term results and low morbidity presented, as well as the many advantages of prostate brachytherapy over other treatments, demonstrates that brachytherapy is an effective treatment for patients with transurethral resection and clinical organ-confined prostate cancer. (author)

  10. Automated construction of an intraoperative high-dose-rate treatment plan library for the Varian brachytherapy treatment planning system.

    Science.gov (United States)

    Deufel, Christopher L; Furutani, Keith M; Dahl, Robert A; Haddock, Michael G

    2016-01-01

    The ability to create treatment plans for intraoperative high-dose-rate (IOHDR) brachytherapy is limited by lack of imaging and time constraints. An automated method for creation of a library of high-dose-rate brachytherapy plans that can be used with standard planar applicators in the intraoperative setting is highly desirable. Nonnegative least squares algebraic methods were used to identify dwell time values for flat, rectangular planar applicators. The planar applicators ranged in length and width from 2 cm to 25 cm. Plans were optimized to deliver an absorbed dose of 10 Gy to three different depths from the patient surface: 0 cm, 0.5 cm, and 1.0 cm. Software was written to calculate the optimized dwell times and insert dwell times and positions into a .XML plan template that can be imported into the Varian brachytherapy treatment planning system. The user may import the .XML template into the treatment planning system in the intraoperative setting to match the patient applicator size and prescribed treatment depth. A total of 1587 library plans were created for IOHDR brachytherapy. Median plan generation time was approximately 1 minute per plan. Plan dose was typically 100% ± 1% (mean, standard deviation) of the prescribed dose over the entire length and width of the applicator. Plan uniformity was best for prescription depths of 0 cm and 0.5 cm from the patient surface. An IOHDR plan library may be created using automated methods. Thousands of plan templates may be optimized and prepared in a few hours to accommodate different applicator sizes and treatment depths and reduce treatment planning time. The automated method also enforces dwell time symmetry for symmetrical applicator geometries, which simplifies quality assurance. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  11. Prostate-specific antigen bounce after high-dose rate brachytherapy with external beam radiation therapy for prostate cancer patients

    International Nuclear Information System (INIS)

    Sakamoto, Naotaka; Kakinoki, Hiroaki; Tsutsui, Akio; Yoshikawa, Masahiro; Iguchi, Atsushi; Matsunobu, Toru; Uehara, Satoru

    2008-01-01

    Prostate-specific antigen (PSA) bounce after high-dose rate (HDR) brachytherapy with external beam radiation therapy (EBRT) for prostate cancer patients was evaluated. Sixty-one patients treated with HDR-brachytherapy followed by EBRT had a minimum follow-up of 12 months (median, 24 months) in our institute. A PSA bounce was defined as a rise of at least 0.1 ng/ml greater than a previous PSA level, with a subsequent decline equal to, or less than, the initial nadir. A PSA bounce was noted in 16 (26.2%) of 61 patients (one patient had a PSA bounce twice). Median time to develop a PSA bounce was 18 months, but 23.5% developed a PSA bounce after 24 months. Median duration of PSA bounce was 6 months and 11.8% had increased PSA within a period of 12 months. Median bounce height was 0.2 ng/ml (range, 0.1 to 3.39 ng/ml). A bounce height of gerater than 2 ng/ml was seen in 11.8%. Clinical characteristics (age, prostate volume, neoadjuvant endocrine therapy, risk classification, stage, pretreatment PSA, Gleason score) do not predict whether or not there will be a PSA bounce. In patients treated with HDR-brachytherapy followed by EBRT, the incidence and characteristics of PSA bounce were similar to those in patients treated with low-dose rate brachytherapy. Physicians should be aware of the possibility of PSA bounce following HDR-brachytherapy with EBRT. (author)

  12. A survey of quality control practices for high dose rate (HDR) and pulsed dose rate (PDR) brachytherapy in the United Kingdom

    Science.gov (United States)

    Bidmead, Margaret; Nisbet, Andrew

    2012-01-01

    Purpose A survey of quality control (QC) currently undertaken in UK radiotherapy centres for high dose rate (HDR) and pulsed dose rate (PDR) brachytherapy has been conducted. The purpose was to benchmark current accepted practice of tests, frequencies and tolerances to assure acceptable HDR/PDR equipment performance. It is 20 years since a similar survey was conducted in the UK and the current review is timed to coincide with a revision of the IPEM Report 81 guidelines for quality control in radiotherapy. Material and methods All radiotherapy centres in the UK were invited by email to complete a comprehensive questionnaire on their current brachytherapy QC practice, including: equipment type, patient workload, source calibration method, level of image guidance for planning, prescribing practices, QC tests, method used, staff involved, test frequencies, and acceptable tolerance limits. Results Survey data was acquired between June and August 2012. Of the 64 centres invited, 47 (73%) responded, with 31 centres having brachytherapy equipment (3 PDR) and fully completing the survey, 13 reporting no HDR/PDR brachytherapy, and 3 intending to commence HDR brachytherapy in the near future. All centres had comprehensive QC schedules in place and there was general agreement on key test frequencies and tolerances. Greatest discord was whether source strength for treatment planning should be derived from measurement, as at 58% of centres, or from the certified value, at 42%. IPEM Report 81 continues to be the most frequently cited source of QC guidance, followed by ESTRO Booklet No. 8. Conclusions A comprehensive survey of QC practices for HDR/PDR brachytherapy in UK has been conducted. This is a useful reference to which centres may benchmark their own practice. However, individuals should take a risk-assessment based approach, employing full knowledge of local equipment, clinical procedures and available test equipment in order to determine individual QC needs. PMID:23378853

  13. Perioperative Interstitial High-Dose-Rate Brachytherapy for the Treatment of Recurrent Keloids

    DEFF Research Database (Denmark)

    Jiang, Ping; Baumann, René; Dunst, Jürgen

    2016-01-01

    was 94%. Pigmentary abnormalities were detected in 3 patients, and an additional 6 patients had a mild delay in the wound-healing process. CONCLUSIONS: The early results of this study prove the feasibility and the efficacy of brachytherapy for the prevention of keloids. The results also suggest....... After (re-)excision of the keloids, a single brachytherapy tube was placed subcutaneously before closing the wound. The target volume covered the scar in total length. Brachytherapy was given in 3 fractions with a single dose of 6 Gy in 5 mm tissue depth. The first fraction was given within 6 hours...

  14. Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy.

    Directory of Open Access Journals (Sweden)

    Luciana Tourinho Campos

    Full Text Available The use of high-dose-rate brachytherapy is currently a widespread practice worldwide. The most common isotope source is 192Ir, but 60Co is also becoming available for HDR. One of main advantages of 60Co compared to 192Ir is the economic and practical benefit because of its longer half-live, which is 5.27 years. Recently, Eckert & Ziegler BEBIG, Germany, introduced a new afterloading brachytherapy machine (MultiSource®; it has the option to use either the 60Co or 192Ir HDR source. The source for the Monte Carlo calculations is the new 60Co source (model Co0.A86, which is referred to as the new BEBIG 60Co HDR source and is a modified version of the 60Co source (model GK60M21, which is also from BEBIG.The purpose of this work is to obtain the dosimetry parameters in accordance with the AAPM TG-43U1 formalism with Monte Carlo calculations regarding the BEBIG 60Co high-dose-rate brachytherapy to investigate the required treatment-planning parameters. The geometric design and material details of the source was provided by the manufacturer and was used to define the Monte Carlo geometry. To validate the source geometry, a few dosimetry parameters had to be calculated according to the AAPM TG-43U1 formalism. The dosimetry studies included the calculation of the air kerma strength Sk, collision kerma in water along the transverse axis with an unbounded phantom, dose rate constant and radial dose function. The Monte Carlo code system that was used was EGSnrc with a new cavity code, which is a part of EGS++ that allows calculating the radial dose function around the source. The spectrum to simulate 60Co was composed of two photon energies, 1.17 and 1.33 MeV. Only the gamma part of the spectrum was used; the contribution of the electrons to the dose is negligible because of the full absorption by the stainless-steel wall around the metallic 60Co. The XCOM photon cross-section library was used in subsequent simulations, and the photoelectric effect, pair

  15. Implementation of High-Dose-Rate Brachytherapy and Androgen Deprivation in Patients With Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lilleby, Wolfgang, E-mail: wolfgang.lilleby@ous-hf.no [Cancer Clinic, Oslo University Hospital, Norwegian Radiumhospital, Department of Radiotherapy and Oncology, Oslo (Norway); Tafjord, Gunnar; Raabe, Nils K. [Cancer Clinic, Oslo University Hospital, Norwegian Radiumhospital, Department of Radiotherapy and Oncology, Oslo (Norway)

    2012-07-01

    Purpose: To evaluate outcome (overall survival [OS], the actuarial 5-year cancer-specific survival [CSS], disease-free survival [DFS], biochemical failure-free survival [BFS]), complications and morbidity in patients treated with high-dose-rate brachytherapy (HDR-BT) boost and hormonal treatment with curative aims. Methods: Between 2004 and 2009, 275 prospectively followed pN0/N0M0 patients were included: 19 patients (7%) with T2, Gleason score 7 and prostate-specific antigen (PSA) <10 and 256 patients (93%) with T3 or Gleason score 8-10 or PSA >20 received multimodal treatment with conformal four-field radiotherapy (prostate/vesiculae 2 Gy Multiplication-Sign 25) combined with HDR-BT (iridium 192; prostate 10 Gy Multiplication-Sign 2) with long-term androgen deprivation therapy (ADT). Results: After a median observation time of 44.2 months (range, 10.4-90.5 months) 12 patients had relapsed clinically and/or biochemically and 10 patients were dead, of which 2 patients died from prostate cancer. Five-year estimates of BFS, CSS, DFS, and OS rates were 98.5%, 99.3%, 95.6%, and 96.3%, respectively. None of the patients with either Gleason score <8 or with intermediate risk profile had relapsed. The number of HDR-BT treatments was not related to outcome. Despite of age (median, 65.7 years; range, 45.7-77 years) and considerable pretreatment comorbidity in 39 of 275 patients, Genitourinary treatment-related morbidity was moderate with long-lasting Radiation Therapy Oncology Group Grade 2 voiding problems in 26 patients (9.5%) and occasionally mucous discharge in 20 patients (7%), none with Grade >2 for gastrointestinal at follow-up. Complications during implantations were related to pubic arch interference (4 patients) and lithotomy time, causing 2 patients to develop compartment syndrome. Conclusion: Despite still preliminary observations, our 5-year outcome estimates favor the implementation of high-dose-rate brachytherapy in high-risk patients combined with conformal

  16. High dose rate interstitial brachytherapy with external beam irradiation for localized prostate cancer. Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Hiratsuka, Junichi; Jo, Yoshimasa; Yoden, Eisaku; Tanaka, Hiroyoshi; Imajo, Yoshinari [Kawasaki Medical School, Kurashiki, Okayama (Japan); Nagase, Naomi; Narihiro, Naomasa; Kubota, Juichi

    2000-12-01

    This study was undertaken to assess the biochemical and pathological results of combined external beam radiotherapy and high dose rate Ir-192 brachytherapy (HDR-Ir192) for clinically localized prostate cancer. Between October 1997 and August 1999, 39 evaluable patients with adenocarcinoma of prostate diagnosed by biopsy were treated with interstitial and external beam irradiation. Patients ranged in age from 58-82 years, with a mean of 69.7 years. T1c, T2 and T3 tumors, according to the UICC classification system (1997), were found in 7, 21 and 11 cases respectively. The mean initial pre-treatment PSA was 35.9 ng/ml (median 13.2), with 77% of the patients having had a pre-treatment PSA greater than 10 ng/ml. Of all patients, 17 had received pre-treatment hormonal therapy. Hormonal pretreatment was stopped at the beginning of radiotherapy in all cases. External beam four-field box irradiation was given to the small pelvis to a dose of 45 Gy/25 fractions. Three HDR-Ir192 treatments were given over a 30-h period, with 5.5 Gy per fraction at the circumference of the prostate gland over the course of this study. Biochemical failure was defined as a PSA level >1.5 ng/ml and rising on three consecutive values. If serial post-treatment PSA levels showed a continuous downward trend, failure was not scored. The patient with clinical evidence of progression was classified as a clinical failure. The median follow-up at the time of evaluation was 19.6 months. A post-treatment PSA level {<=}1.0 ng/ml was seen in 26 (67%) patients, and values from >1.0 to {<=}2.0 ng/ml were seen in 10 (26%) patients. Biochemical failure was not seen in 38 patients except for one patient who developed a distant bone metastasis with negative prostatic biopsy 15 months after treatment. Biochemical control rate was 100% (38/38) except for the patient with bone metastasis classified as clinical failure. Negative biopsies 18 months after treatment were found in 93% (14/15) of patients. Only one patient

  17. Two fractions of high-dose-rate brachytherapy in the management of cervix cancer: clinical experience with and without chemotherapy

    International Nuclear Information System (INIS)

    Sood, Brij M.; Gorla, Giridhar; Gupta, Sajel; Garg, Madhur; Deore, Shivaji; Runowicz, Carolyn D.; Fields, Abbie L.; Goldberg, Gary L.; Anderson, Patrick S.; Vikram, Bhadrasain

    2002-01-01

    Purpose: In recent years, high-dose-rate brachytherapy has become popular in the management of carcinoma of the uterine cervix, because it eliminates many of the problems associated with low-dose-rate brachytherapy. However, the optimum time-dose-fractionation remains controversial. Two fractions of high-dose-rate brachytherapy are convenient for patients, but most radiation oncologists in the United States do not use them, because of fear that they could lead to excessive rectal or bladder toxicity. Here we present our experience, which suggests that a two-fraction regimen is indeed safe and effective. Methods: We treated 49 patients with Stages I-III biopsy-proven carcinoma of the uterine cervix by external beam radiation therapy (EBRT), plus two fractions of high-dose-rate brachytherapy. The histology was squamous cell carcinoma in 43 patients (88%) and nonsquamous in 6 (12%). The median size of the primary tumor was 6 cm (range: 3-10 cm). Each patient received EBRT to the pelvis to a median dose of 45 Gy (range: 41.4-50.4 Gy), followed by a parametrial boost when indicated. Thirty patients (61%) also received irradiation to the para-aortic lymph nodes to a dose of 45 Gy. After EBRT, each patient underwent two applications of high-dose-rate brachytherapy, 1 week apart. The dose delivered to point A was 9 Gy per application for 49 applications (50%) and 9.4 Gy for 43 applications (44%), and it varied from 7 to 11 Gy for the rest (6%). The total dose to the rectum from both high-dose-rate brachytherapy applications ranged from 4.7 to 11.7 Gy (median: 7.1 Gy), and the total dose to the bladder from 3.8 to 15.5 Gy (median: 10.5 Gy). Twenty-five of the 49 patients (51%) received concomitant chemotherapy (cisplatin 20 mg/m 2 /day for 5 days) during the first and fourth weeks of EBRT and once after the second high-dose-rate brachytherapy application. Chemotherapy was not assigned in a randomized fashion. The use of chemotherapy increased during the time period spanned

  18. High dose rate brachytherapy for carcinoma of the cervix: risk factors for late rectal complications

    International Nuclear Information System (INIS)

    Uno, Takashi; Itami, Jun; Aruga, Moriyo; Kotaka, Kikuo; Fujimoto, Hajime; Minoura, Shigeki

    1996-01-01

    Purpose/Objective: To determine the incidence of late rectal complications in patients treated with high dose rate brachytherapy for FIGO stage IIB, IIIB carcinoma of the uterine cervix, and to evaluate the treatment factors associated with an increased probability of treatment complications. Materials and Methods: Records of 100 patients with FIGO IIB or IIIB cervical carcinoma treated with definitive irradiation using high dose rate intracavitary brachytherapy (HDR-ICR) between 1977 and 1994 were retrospectively reviewed. For each HDR-ICR session, 6 Gy isodose volume was reconstructed three dimensionally and the following three parameters were determined to represent this isodose volume, length (L); maximum longitudinal distance of 6 Gy isodose area in an oblique frontal plane containing the intrauterine applicator, width (W); maximum width of 6 Gy isodose area in the same plane, height (H); maximum dimension of 6 Gy isodose area perpendicular to the intrauterine applicator determined in the oblique sagittal plane. Point P/Q (2 cm ventral/dorsal from the proximal retention point of the intrauterine source) and point R/S (2 cm ventral/dorsal from the midpoint of the ovoid sources) were also defined retrospectively and HDR-ICR dose at these points were calculated. Statistical analyses were performed to determine the treatment factors predictive of late rectal complications. Results: The 5-year cumulative cause-specific disease-free survival rate was 50% for all, 74% for Stage IIB, and 38% for Stage IIIB, with a significant difference between two FIGO Stages (p=0.0004). Of patients treated for both stages, 30% and 36% had experienced moderate to severe (Grade 2-4) complications at 3 and 5 years, respectively. Average H value (p=0.013) and cumulative point S dose by HDR-ICR (p=0.020) were significantly correlated with the incidence of late rectal complications (Student's t-test), whereas these factors did not significantly affect the probability of pelvic control. No

  19. Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: Source dosimetry, treatment planning, equipment performance and in vivo verification techniques

    OpenAIRE

    Palmer, A; Bradley, D; Nisbet, A

    2012-01-01

    This study provides a review of recent publications on the physics-aspects of dosimetric accuracy in high dose rate (HDR) brachytherapy. The discussion of accuracy is primarily concerned with uncertainties, but methods to improve dose conformation to the prescribed intended dose distribution are also noted. The main aim of the paper is to review current practical techniques and methods employed for HDR brachytherapy dosimetry. This includes work on the determination of dose rate fields around...

  20. Local control related to Kerma rate in T2/T3 breast cancers treated by external irradiation and brachytherapy

    International Nuclear Information System (INIS)

    Campana, F.; Danhier, S.; Kouz, J.; Asselain, B.; Vilcoq, J.R.; Gautier, C; Fourquet, A.

    1996-01-01

    Introduction: This study was conducted to determine the impact of the brachytherapy parameters on local control in patients treated with irradiation alone for breast cancer. Material and Methods: From 1985 to 1991, 241 patients with T2 (187pts) T3 (54 pts) N0 (196 pts) N1 (45 pts) M0 breast cancer have been treated with the combination of external irradiation and brachytherapy boost without surgery. Doses delivered to the whole breast and the regional nodes were 54 Gy and 50 Gy respectively (1.8 or 2 Gy/fraction, 5 fr/wk). Twenty Gy were then boosted to the primary tumor, according to the tumor shrinkage, by Ir 192 implants. Plastic tubes and rigid needles were used in 85 % and 15 % of the cases respectively. The brachytherapy boost was delivered at 85% of the basal dose rate (Reference dose rate) according to the Paris system. In some instances, dose distribution heterogeneities were observed leading to the choice of another reference isodose. Results: Median follow-up for the entire population was 75 months (9-122). Local control at 6 years follow-up for T2 and T3 was 76% (+/- 6%). Age, SBR grading and steroid receptors were found to be significantly correlated to local control. The role of the brachytherapy boost was analysed. Reference dose rate was not found to have any impact on local control, (≤ 0.6 vs > 0.6 Gy/h). This result was perhaps linked to the particular choice of the reference isodose. To avoid this bias we have evaluated the impact of the Kerma rate (Activity x Time x total length) on local control. Median kerma rate was 8600 μGy h -1 cm -1 m 2 (2200-16600). Local control rate for T2 at 6 years was 77% +/- 8% (Kerma >8600) and 73 %+/- 10% (Kerma ≤ 8600). For T3 local control rate was 82% +/-12% (Kerma >8600) and 37 % +/- 34 % (p<0.0002). Conclusion: This study demonstrated that the impact of brachytherapy on local control was better evaluated by the Kerma rate than by the reference dose rate. Whereas the basal dose rate cannot be changed

  1. Bladder–Rectum Spacer Balloon in High-Dose-Rate Brachytherapy in Cervix Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Rai, Bhavana [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Patel, Firuza D., E-mail: firuzapatel@gmail.com [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Chakraborty, Santam; Sharma, Suresh C.; Kapoor, Rakesh [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Aprem, Abi Santhosh [Corporate R and D Division, HLL Lifecare Limited, Karamana, Trivandrum (India)

    2013-04-01

    Purpose: To compare bladder and rectum doses with the use of a bladder–rectum spacer balloon (BRSB) versus standard gauze packing in the same patient receiving 2 high-dose-rate intracavitary brachytherapy fractions. Methods and Materials: This was a randomized study to compare the reduction in bladder and rectum doses with the use of a BRSB compared with standard gauze packing in patients with carcinoma of the cervix being treated with high-dose-rate intracavitary brachytherapy. The patients were randomized between 2 arms. In arm A, vaginal packing was done with standard gauze packing in the first application, and BRSB was used in the second application. Arm B was the reverse of arm A. The International Commission for Radiation Units and Measurement (ICRU) point doses and doses to 0.1-cm{sup 3}, 1-cm{sup 3}, 2-cm{sup 3}, 5-cm{sup 3}, and 10-cm{sup 3} volumes of bladder and rectum were compared. The patients were also subjectively assessed for the ease of application and the time taken for application. Statistical analysis was done using the paired t test. Results: A total of 43 patients were enrolled; however, 3 patients had to be excluded because the BRSB could not be inserted owing to unfavorable local anatomy. Thus 40 patients (80 plans) were evaluated. The application was difficult in 3 patients with BRSB, and in 2 patients with BRSB the application time was prolonged. There was no significant difference in bladder doses to 0.1 cm{sup 3}, 1 cm{sup 3}, 2 cm{sup 3}, 5 cm{sup 3}, and 10 cm{sup 3} and ICRU bladder point. Statistically significant dose reductions to 0.1-cm{sup 3}, 1-cm{sup 3}, and 2-cm{sup 3} volumes for rectum were observed with the BRSB. No significant differences in 5-cm{sup 3} and 10-cm{sup 3} volumes and ICRU rectum point were observed. Conclusion: A statistically significant dose reduction was observed for small high-dose volumes in rectum with the BRSB. The doses to bladder were comparable for BRSB and gauze packing. Transparent balloons of

  2. CT-guided high-dose-rate brachytherapy of unresectable hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Collettini, Federico; Schreiber, Nadja; Schnapauff, Dirk; Denecke, Timm; Hamm, Bernd; Gebauer, Bernhard; Wust, Peter; Schott, Eckart

    2015-01-01

    The purpose of the present study was to evaluate the clinical outcome of CT-guided high-dose-rate brachytherapy (CT-HDRBT) in patients with unresectable hepatocellular carcinoma (HCC). Over a 6-year period, 98 patients with 212 unresectable HCC underwent CT-HDRBT applying a 192 Ir source at our institution. Magnetic resonance imaging (MRI) follow-up was performed 6 weeks after the intervention and then every 3 months. The primary endpoint was local tumor control (LTC); secondary endpoints included progression-free survival (PFS) and overall survival (OS). Patients were available for MRI evaluation for a mean follow-up of 23.1 months (range 4-64 months; median 20 months). Mean tumor diameter was 5 cm (range 1.8-12 cm). Eighteen of 212 (8.5 %) tumors showed local progression after a mean LTC of 21.1 months. In all, 67 patients (68.4 %) experienced distant tumor progression. The mean PFS was 15.2 months. Forty-six patients died during the follow-up period. Median OS was 29.2 months. Actuarial 1-, 2-, and 3-year OS rates were 80, 62, and 46 %, respectively. CT-HDRBT is an effective therapy to attain local tumor control in patients with unresectable HCC. Prospective randomized studies comparing CT-HDRBT with the standard treatments like Radiofrequency ablation (RFA) and chemoembolization (TACE) are mandatory. (orig.) [de

  3. Intestinal morphological effect of brachytherapy of low rate of dose, administrated in therapeutic form and its clinical manifestations in uterine cervix tumors

    International Nuclear Information System (INIS)

    Mendoza, Carmen; Contreras, Manuel

    2005-01-01

    Brachytherapy is effective to eradicate cancer in the cervix, in order to obtain the control of disease we use high dose with vesical and rectum toxicity. The objective is to investigate if brachytherapy by itself is the cause of intestinal damage, to know in addition if the intensity of the clinic manifestations is in direct relation to the given radiation dose and this gets worse when it is received in several applications. Hypothesis: The intensity of the radiation with brachytherapy of low rate of dose is proportional to the degree of clinical manifestations and morphologic damage of the intestine. A prospective analysis was made inpatients with cancer of cervix from september 2000 to june 2004. Each patient who enters to the department of brachytherapy of the hospital must be done laboratory examination that includes plaque and coagulation test before being accepted. We use the clinical card and a table in order to register data concerning teletherapy, implants of brachytherapy of low rate of dose, symptoms of intestinal toxicity and details of colonoscopia. Subsequent to the hospitable discharge the patient is sent to gastroenterology for clinical evaluation and to realize colonoscopia. From september 2000 to june 2004, 540 patients entered, 80 patients (15%) displayed intestinal manifestations, all received teletherapy and brachytherapy, nobody else received brachytherapy in exclusive form and only one patient (0.1%) received the total of the dose in 2 applications. The equipment of teletherapy Primus with energy of 6 and 18 Mv and implants of brachytherapy Manchester were used (70/55 patients). 79 (98%) patients received dose between 85-75 Gy in one single application, 58 (72%) received the total of the dose to the tumor, 21 (26%) in vaginal mucosa. Discussion: Brachytherapy is the cause of the damages in the intestinal mucosa. (The author)

  4. Comparison of192Ir,169Yb, and60Co high-dose rate brachytherapy sources for skin cancer treatment.

    Science.gov (United States)

    Safigholi, Habib; Meigooni, Ali S; Song, William Y

    2017-09-01

    To evaluate the possibility of utilizing the high-dose rate (HDR) 169 Yb and 60 Co sources, in addition to 192 Ir, for the treatment of skin malignancies with conical applicators. Monte Carlo (MC) simulations were used to benchmark the dosimetric parameters of single 169 Yb (4140), 60 Co (Co0.A86), and 192 Ir (mHDR-V2) brachytherapy sources in a water phantom and compared their results against published data. A standard conical tungsten alloy Leipzig-style applicator (Stand.Appl) was used for determination of the dose distributions at various depths with a single dwell position of the HDR sources. The HDR sources were modeled with its long axis parallel to the treatment plane within the opening section of the applicator. The source-to-surface distance (SSD) was 1.6 cm, which included a 0.1 cm thick removable plastic end-cap used for clinical applications. The prescription depth was considered to be 0.3 cm in a water phantom following the definitions in the literature for this treatment technique. Dose distributions generated with the Stand.Appl and the 169 Yb and 60 Co sources have been compared with those of the 192 Ir source, for the same geometry. Then, applicator wall thickness for the 60 Co source was increased (doubled) in MC simulations in order to minimize the leakage dose and penumbra to levels that were comparable to that from the 192 Ir source. For each source-applicator combination, the optimized plastic end-cap dimensions were determined in order to avoid over-dosage to the skin surface. The normalized dose profiles at the prescription depth for the 169 Yb-Stand.Appl and the 60 Co-double-wall applicator were found to be similar to that of the 192 Ir-Stand.Appl, with differences Ir-, 169 Yb- and 60 Co-Stand.Appl were found to be comparable to the values with the 60 Co-double-walled applicator, with differences Ir-, 169 Yb-Stand.Appl, and 60 Co-double-wall applicators respectively. The leakage dose around the Stand.Appl for distance > 2 cm from the

  5. Performance assessment of the BEBIG MultiSource® high dose rate brachytherapy treatment unit

    Science.gov (United States)

    Palmer, Antony; Mzenda, Bongile

    2009-12-01

    A comprehensive system characterisation was performed of the Eckert & Ziegler BEBIG GmbH MultiSource® High Dose Rate (HDR) brachytherapy treatment unit with an 192Ir source. The unit is relatively new to the UK market, with the first installation in the country having been made in the summer of 2009. A detailed commissioning programme was devised and is reported including checks of the fundamental parameters of source positioning, dwell timing, transit doses and absolute dosimetry of the source. Well chamber measurements, autoradiography and video camera analysis techniques were all employed. The absolute dosimetry was verified by the National Physical Laboratory, UK, and compared to a measurement based on a calibration from PTB, Germany, and the supplied source certificate, as well as an independent assessment by a visiting UK centre. The use of the 'Krieger' dosimetry phantom has also been evaluated. Users of the BEBIG HDR system should take care to avoid any significant bend in the transfer tube, as this will lead to positioning errors of the source, of up to 1.0 mm for slight bends, 2.0 mm for moderate bends and 5.0 mm for extreme curvature (depending on applicators and transfer tube used) for the situations reported in this study. The reason for these errors and the potential clinical impact are discussed. Users should also note the methodology employed by the system for correction of transit doses, and that no correction is made for the initial and final transit doses. The results of this investigation found that the uncorrected transit doses lead to small errors in the delivered dose at the first dwell position, of up to 2.5 cGy at 2 cm (5.6 cGy at 1 cm) from a 10 Ci source, but the transit dose correction for other dwells was accurate within 0.2 cGy. The unit has been mechanically reliable, and source positioning accuracy and dwell timing have been reproducible, with overall performance similar to other existing HDR equipment. The unit is capable of high

  6. Implementation of the global risk analysis in pulsed-dose rate brachytherapy: methods and results.

    Science.gov (United States)

    Mazeron, R; Aguini, N; Rivin Del Campo, E; Dumas, I; Gensse, M-C; Brusadin, G; Lefkopoulos, D; Deutsch, E; Haie-Meder, C

    2015-04-01

    To report the application of the global risk analysis (GRA) in the pulsed-dose rate (PDR) brachytherapy workflow. Analyses were led by a multidisciplinary working group established within the unit with the guidance of a quality engineer. First, a mapping of hazardous situations was developed as a result of interactions between the patient workflow for a treatment using PDR brachytherapy split into 51 sub-phases with a comprehensive list of the hazards that he/she faces (44). Interactions, when relevant, were sorted by level of priority: to be treated immediately, secondarily (the group is not entitled to treat the situation), or later (safe situation). Secondly, for each high priority dangerous situation, scenarios were developed to anticipate their potential consequences. Criticality was assessed, using likelihood and severity scales and a matrix, which allocated risks into categories: acceptable (C1), tolerable under control (C2) and unacceptable (C3). Then, corrective actions were proposed and planned when relevant, after assessment of their feasibility with a scale of effort. Finally, the criticality of the scenarios was reevaluated, taking into account the implementation of these actions, leading to a residual risk mapping, which could trigger additional proposals of actions. Two thousand one hundred and eighty-four potential interactions between the list of hazards and the workflow were analyzed. Mapping of dangerous situations identified 213 relevant interactions, from which 61 were considered with high priority. One hundred and twenty-six scenarios were generated: 68 with a low criticality (74.3%), 58 with an intermediate score (25.7%). No scenario with the highest criticality was individualized. Twenty-one corrective actions were planned. Mapping of residual risk resulted in the disappearance of most C2 risks, leaving 5 C2 scenarios (4%), for which four monitoring indicators were implemented in addition to the corrected actions decided on. The

  7. A phantom for verification of dwell position and time of a high dose rate brachytherapy source

    International Nuclear Information System (INIS)

    Madebo, M.; Kron, T.; Pillainayagam, J.; Franich, R.

    2012-01-01

    Accuracy of dwell position and reproducibility of dwell time are critical in high dose rate (HDR) brachytherapy. A phantom was designed to verify dwell position and dwell time reproducibility for an Ir-192 HDR stepping source using Computed Radiography (CR). The central part of the phantom, incorporating thin alternating strips of lead and acrylic, was used to measure dwell positions. The outer part of the phantom features recesses containing different absorber materials (lead, aluminium, acrylic and polystyrene foam), and was used for determining reproducibility of dwell times. Dwell position errors of <1 mm were easily detectable using the phantom. The effect of bending a transfer tube was studied with this phantom and no change of clinical significance was observed when varying the curvature of the transfer tube in typical clinical scenarios. Changes of dwell time as low as 0.1 s, the minimum dwell time of the treatment unit, could be detected by choosing dwell times over the four materials that produce identical exposure at the CR detector.

  8. Towards enabling ultrasound guidance in cervical cancer high-dose-rate brachytherapy

    Science.gov (United States)

    Wong, Adrian; Sojoudia, Samira; Gaudet, Marc; Yap, Wan Wan; Chang, Silvia D.; Abolmaesumi, Purang; Aquino-Parsons, Christina; Moradi, Mehdi

    2014-03-01

    MRI and Computed Tomography (CT) are used in image-based solutions for guiding High Dose Rate (HDR) brachytherapy treatment of cervical cancer. MRI is costly and CT exposes the patients to ionizing radiation. Ultrasound, on the other hand, is affordable and safe. The long-term goal of our work is to enable the use of multiparametric ultrasound imaging in image-guided HDR for cervical cancer. In this paper, we report the development of enabling technology for ultrasound guidance and tissue typing. We report a system to obtain the 3D freehand transabdominal ultrasound RF signals and B-mode images of the uterus, and a method for registration of ultrasound to MRI. MRI and 3D ultrasound images of the female pelvis were registered by contouring the uterus in the two modalities, creating a surface model, followed by rigid and B-spline deformable registration. The resulting transformation was used to map the location of the tumor from the T2-weighted MRI to ultrasound images and to determine cancerous and normal areas in ultrasound. B-mode images show a contrast for cancer vs. normal tissue. Our study shows the potential and the challenges of ultrasound imaging in guiding cervical cancer treatments.

  9. Preparation and determination of kerma for Iridium 192 sources of low dose rate for brachytherapy

    International Nuclear Information System (INIS)

    Tendilla, J.I.; Tovar M, V.; Mitsoura, E.; Aguilar H, F.; Alanis M, J.

    2000-01-01

    The practice of Brachytherapy with Iridium-192 sources of low dose rate (0.4 - 0.8 Gy/h) is a technique used in the treatment of diverse illnesses. in this work the preparation, quality control and calibration are presented in terms of kerma in air of Iridium-192 using as target these recycled Iridium-Platinum wires. The targets were obtained as decayed sources of different radio therapeutical centers in the country and they were characterized by Scanning electron microscopy in order to determine their chemical composition. Subsequently it was developed an experimental design to establish the effect of neutron flux, geometrical array and irradiation time over the activity and percentage of the sources homogeneity. The homogeneity was determined by auto radiography and by Gamma spectroscopy. Once the optimal irradiation conditions were established, it is determined the apparent activity and kerma in air using a well type ionization chamber with traceability to a primary laboratory. Iridium-192 sources were obtained with an average homogeneity 96 %, apparent activity 282.129 ± 0.531 M Bq and kerma in air 0.03200 ± 0.00006 m Gy m/h A. (Author)

  10. Proposal of a high dose rate brachytherapy model for in vitro radiobiology studies

    International Nuclear Information System (INIS)

    Geraldo, Jony M.; Nogueira, Luciana B.; Andrade, Lidia M.; Trindade, Cassia; Furtado, Clascidia A.; Ladeira, Luiz Orlando

    2016-01-01

    The aim of this research was to develop an easy and reproducible approach for experimental HDR brachytherapy allowing in vitro irradiation studies based on clinical parameters. An acrylic platform was designed to attach T25 tissue culture flasks and multi-well tissue culture plates as well as kept the catheters in a fixed position during irradiation. CT images were taken and the irradiation was planned for 550cGy dose applied on adherent tumor cells. Dosimetric measurements were done and all relevant uncertainties were taken into account in order to figure out the correct dose range received by the cells. Tumor cells were irradiated two times over an interval of 24h between irradiations. Proof of concepts of this approach was carried out by biological effects analysis using a radioresistant human epidermoid carcinoma A431 cell line. Cellular proliferation and cell cycle phase were assessed by Trypan blue exclusion assay and DNA content analysis by flow cytometry, respectively. This approach allowed uniform dose distribution around the arrangement in all types of tissue culture plastics evaluated. Corrections due to uncertainties were managed. Regarding in vitro assays there was a significant (p<0.05) decreasing of cellular proliferation rate in irradiated cells. Moreover, increased percentage of cells arrested in G2/M phase (32.3 ± 1.5%) were observed for treated group compared with untreated cells. (author)

  11. Treatment of regional cutaneous nodular metastases from melanoma using high-dose rate mould brachytherapy.

    Science.gov (United States)

    Chaudhuri, Anupam; De-Groot, Charles; Seel, Matthew; Jolly, Mike; Cameron, Tina

    2011-04-01

    The involvement of a wide body surface area by regional cutaneous nodular metastases (RCNM) from melanoma poses a significant therapeutic challenge. We report our experience from Waikato Hospital, Hamilton, New Zealand in successfully treating this condition with high-dose rate (HDR) surface mould brachytherapy (BT). We analysed six patients who had surgery and then developed RCNM, which was treated in our department by HDR mould BT using Iridium 192. Five out of six patients were treated with a dose of 30 Gy in five fractions to wide field with a further 6 Gy boost to tumour nodules. Our first patient received a higher dose of 36 Gy in six fractions followed by 6 Gy boost to tumour nodules. All patients experienced a complete response (CR). Median follow up was 23 months and side effects were minimal, only Radiation Therapy Oncology Group (RTOG) grade I/II early and late toxicity. To date, no in-field recurrence has been observed. Two patients died from metastatic disease at 33 and 34 months of follow up. There was a CR in all cases without in-field recurrence. To our knowledge, this is the first reported experience in treating skin melanoma with a BT surface mould. We recommend that BT surface mould should be considered when treating patients with RCNM. © 2011 The Authors. Journal of Medical Imaging and Radiation Oncology © 2011 The Royal Australian and New Zealand College of Radiologists.

  12. Treatment of regional cutaneous nodular metastases from melanoma using high-dose rate mould brachytherapy

    International Nuclear Information System (INIS)

    Chaudhuri, Anupam; De-Groot, Charles; Seel, Matthew; Jolly, Mike; Cameron Tina

    2011-01-01

    Full text: The involvement of a wide body surface area by regional cuta neous nodular metastases (RCNM) from melanoma poses a significant thera peutic challenge. We report our experience from Waikato Hospital, Hamilton, New Zealand in successfully treating this condition with high-dose rate (HDR) surface mould brachytherapy (BT). Methods: We analysed six patients who had surgery and then developed RCNM, which was treated in our department by HDR mould BT using Iridium 192. Five out of six patients were treated with a dose of 30 Gy in five fractions to wide field with a further 6 Gy boost to tumour nodules. Our first patient received a higher dose of 36 Gy in six fractions followed by 6 Gy boost to tumour nodules. Results: All patients experienced a complete response (CR). Median follow up was 23 months and side effects were minimal, only Radiation Therapy Oncol ogy Group (RTOG) grade I/ll early and late toxicity. To date, no in-field recurrence has been observed. Two patients died from metastatic disease at 33 and 34 months of follow up. Conclusion: There was a CR in all cases without in-field recurrence. To our knowledge, this is the first reported experience in treating skin melanoma with a BT surface mould. We recommend that BT surface mould should be considered when treating patients with RCNM.

  13. A quality assurance (QA) system with a web camera for high-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Hirose, Asako; Ueda, Yoshihiro; Ohira, Shingo

    2016-01-01

    The quality assurance (QA) system that simultaneously quantifies the position and duration of an 192 Ir source (dwell position and time) was developed and the performance of this system was evaluated in high-dose-rate brachytherapy. This QA system has two functions to verify and quantify dwell position and time by using a web camera. The web camera records 30 images per second in a range from 1,425 mm to 1,505 mm. A user verifies the source position from the web camera at real time. The source position and duration were quantified with the movie using in-house software which was applied with a template-matching technique. This QA system allowed verification of the absolute position in real time and quantification of dwell position and time simultaneously. It was evident from the verification of the system that the mean of step size errors was 0.3±0.1 mm and that of dwell time errors 0.1 ± 0.0 s. Absolute position errors can be determined with an accuracy of 1.0 mm at all dwell points in three step sizes and dwell time errors with an accuracy of 0.1% in more than 10.0 s of the planned time. This system is to provide quick verification and quantification of the dwell position and time with high accuracy at various dwell positions without depending on the step size. (author)

  14. Proposal of a postal system for Ir-192 sources calibration used in high dose rate brachytherapy with LiF:Mn:Ti thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Vieira, W.S.; Borges, J.C.; Almeida, C.E.V.

    1998-01-01

    A proposal in order to improve the brachytherapy quality control and to allow postal intercomparison of Ir-192 sources used in high dose rate brachytherapy has been presented. The LiF: Mn: Ti (TLD 100) detector has been selected for such purpose. The experimental array and the TLDs irradiation and calibration techniques, at the treatment units, have been specified in the light of more recent methodology of Ir-192 calibration sources. (Author)

  15. Assessment of dose-volume histograms in brachytherapy 3D high-rate; Evaluacion de los histogramas dosis volumen en braquiterapia de alta tasa 3D

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Barrado, A.; Tripero Oter, J.; Sanchez Jimenez, E.; Sanchez-Reyes, A.

    2013-07-01

    The use of systems of treatment planning using 3D reconstruction algorithms are becoming more frequent in brachytherapy treatments. The implementation of these systems entails great qualitative and quantitative procedural changes in the way to evaluate the clinical dosimetry about the 2D classical systems. This paper describes the experience of our Centre in employment and prescription dose using histograms dose-volume in the treatment of brachytherapy of high rate. (Author)

  16. An open-source genetic algorithm for determining optimal seed distributions for low-dose-rate prostate brachytherapy.

    Science.gov (United States)

    McGeachy, P; Madamesila, J; Beauchamp, A; Khan, R

    2015-01-01

    An open source optimizer that generates seed distributions for low-dose-rate prostate brachytherapy was designed, tested, and validated. The optimizer was a simple genetic algorithm (SGA) that, given a set of prostate and urethra contours, determines the optimal seed distribution in terms of coverage of the prostate with the prescribed dose while avoiding hotspots within the urethra. The algorithm was validated in a retrospective study on 45 previously contoured low-dose-rate prostate brachytherapy patients. Dosimetric indices were evaluated to ensure solutions adhered to clinical standards. The SGA performance was further benchmarked by comparing solutions obtained from a commercial optimizer (inverse planning simulated annealing [IPSA]) with the same cohort of 45 patients. Clinically acceptable target coverage by the prescribed dose (V100) was obtained for both SGA and IPSA, with a mean ± standard deviation of 98 ± 2% and 99.5 ± 0.5%, respectively. For the prostate D90, SGA and IPSA yielded 177 ± 8 Gy and 186 ± 7 Gy, respectively, which were both clinically acceptable. Both algorithms yielded reasonable dose to the rectum, with V100 < 0.3 cc. A reduction in dose to the urethra was seen using SGA. SGA solutions showed a slight prostate volume dependence, with smaller prostates (<25 cc) yielding less desirable, although still clinically viable, dosimetric outcomes. SGA plans used, on average, fewer needles than IPSA (21 vs. 24, respectively), which may lead to a reduction in urinary toxicity and edema that alters post-implant dosimetry. An open source SGA was validated that provides a research tool for the brachytherapy community. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  17. Low-dose-rate intraoperative brachytherapy combined with external beam irradiation in the conservative treatment of soft tissue sarcoma

    International Nuclear Information System (INIS)

    Delannes, M.; Thomas, L.; Martel, P.; Bonnevialle, P.; Stoeckle, E.; Chevreau, Ch.; Bui, B.N.; Daly-Schveitzer, N.; Pigneux, J.; Kantor, G.

    2000-01-01

    Purpose: Conservative treatment of soft tissue sarcomas most often implies combination of surgical resection and irradiation. The aim of this study was to evaluate low-dose-rate intraoperative brachytherapy, delivered as a boost, in the local control of primary tumors, with special concern about treatment complications. Methods and Materials: Between 1986 and 1995, 112 patients underwent intraoperative implant. This report focuses on the group of 58 patients with primary sarcomas treated by combination of conservative surgery, intraoperative brachytherapy, and external irradiation. Most of the tumors were located in the lower limbs (46/58--79%). Median size of the tumor was 10 cm, most of the lesions being T2-T3 (51/58--88%), Grade 2 or 3 (48/58--83%). The mean brachytherapy dose was 20 Gy and external beam irradiation dose 45 Gy. In 36/58 cases, iridium wires had to be placed on contact with neurovascular structures. Results: With a median follow-up of 54 months, the 5-year actuarial survival was 64.9%, with a 5-year actuarial local control of 89%. Of the 6 patients with local relapse, 3 were salvaged. Acute side effects, essentially wound healing problems, occurred in 20/58 patients, late side effects in 16/58 patients (7 neuropathies G2 to G4). No amputation was required. The only significant factor correlated with early side effects was the location of the tumor in the lower limb (p = 0.003), and with late side effects the vicinity of the tumor with neurovascular structures (p = 0.009). Conclusion: Brachytherapy allows early delivery of a boost dose in a reduced volume of tissue, precisely mapped by the intraoperative procedure. Combined with external beam irradiation, it is a safe and efficient treatment technique leading to high local control rates and limited functional impairment

  18. Rectal dose assessment in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer; Avaliacao da dose no reto em pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do cancer do colo uterino

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Jetro Pereira de [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Faculdade de Medicina; Rosa, Luiz Antonio Ribeiro da [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)], e-mail: lrosa@ird.gov.br; Batista, Delano Valdivino Santos; Bardella, Lucia Helena [Instituto Nacional de Cancer (INCA), Rio de Janeiro, RJ (Brazil). Unit of Medical Physics; Carvalho, Arnaldo Rangel [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. of Thermoluminescent Dosimetry

    2009-03-15

    Objective: The present study was aimed at developing a thermoluminescent dosimetric system capable of assessing the doses delivered to the rectum of patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. Materials and methods: LiF:Mg,Ti,Na powder was the thermoluminescent material utilized for evaluating the rectal dose. The powder was divided into small portions (34 mg) which were accommodated in a capillary tube. This tube was placed into a rectal probe that was introduced into the patient's rectum. Results: The doses delivered to the rectum of six patients submitted to high-dose-rate brachytherapy for uterine cervix cancer evaluated by means of thermoluminescent dosimeters presented a good agreement with the planned values based on two orthogonal (anteroposterior and lateral) radiographic images of the patients. Conclusion: The thermoluminescent dosimetric system developed in the present study is simple and easy to be utilized as compared to other rectal dosimetry methods. The system has shown to be effective in the evaluation of rectal doses in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. (author)

  19. Treatment of Recurrent Bronchial Carcinoma: The Role of High-Dose-Rate Endoluminal Brachytherapy

    International Nuclear Information System (INIS)

    Hauswald, Henrik; Stoiber, Eva; Rochet, Nathalie; Lindel, Katja; Grehn, Christian; Becker, Heinrich D.; Debus, Juergen; Harms, Wolfgang

    2010-01-01

    Purpose: This study's aim was to assess outcome and toxicity of high-dose-rate endoluminal brachytherapy (HDREB) for recurrent bronchial carcinoma. Methods and Materials: From 1987 to 2005, 41 patients were treated with HDREB for symptomatic recurrent bronchial carcinoma. All patients had previously undergone external beam radiotherapy (EBRT) with a median dose of 56 Gy (range, 30-70 Gy). The median HDREB dose applied was 15 Gy (range, 5-29 Gy). The median time interval between primary EBRT and reirradiation was 9 months (range, 2-54 months). Results: After a median follow-up of 6.7 months, the 6-, 12-, and 24-month overall survival rates were 58%, 18%, and 7%, respectively. The median overall survival time was 6.7 months. Local remission was achieved in 73% of patients (n = 30). A total of 24% of patients (n = 10) showed no response or progressive disease within 8 weeks after treatment. In 1 patient, treatment response was not documented. The 6-, 12-, and 24-month local control rates were 38%, 17%, and 3%, respectively. The median local progression-free survival time was 4 months (range, 1-23 months). Prognostic factors were a total dose of ≥15 Gy of HDREB (p = 0.029) and a Karnofsky performance score of ≥80% (p = 0.0012). The cause of death was locoregional progression in 27% of patients (n = 11), distant metastases in 24% of patients (n = 10), fatal hemorrhage in 15% of patients (n = 6), and other causes in 29% of patients (n = 12). None of the patients with locally controlled disease showed grade 3 or 4 late effects. Conclusions: Palliative treatment of symptomatic, locally recurrent bronchial carcinoma with HDREB can effectively relieve symptoms in the majority of patients while causing only few complications. Still, time to progression is short.

  20. External beam radiation and high-dose-rate brachytherapy for elderly patients with gastroesophageal junction adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Wei Zhang

    2017-07-01

    Full Text Available Purpose: The aim of this study was to retrospectively observe and analyze the long-term treatment outcomes of 96 elderly patients with gastroesophageal junction adenocarcinoma (GEJAC who were treated with californium-252 (252Cf neutron brachytherapy (NBT in combination with external beam radiotherapy (EBRT with or without chemotherapy. Material and methods: From January 2002 to November 2012, 96 patients with GEJAC underwent treatment. The total radiation dose to the reference point via NBT was 8-25 Gy-eq in 2 to 5 fractions, with 1 fraction per week. The total dose via EBRT was 40-54 Gy, which was delivered over a period of 4 to 5.5 weeks with normal fraction. Results: The median survival time for the 96 patients was 15.3 months, and the 1-, 2-, 3-, and 5-year rates of overall survival (OS were 62.5%, 33.7%, 20.1%, and 7.9%, respectively. The 1-, 2-, 3-, and 5-year rates for local-regional control (LRC were 78.7%, 57.9%, 41.8%, and 26.4%, respectively. The patients’ age was an independent factor that was significantly associated with OS (p = 0.006 and LRC (p = 0.0005, according to univariate analysis. The 3-year OS (LRC was 31.9% (62.9% for patients aged 70-74 years and 16.1% (19.5% for patients aged ≥ 75 years. From the time of treatment completion to the development of local-regional recurrence or death, 5 (5.2% patients experienced fistula and 7 (7.3% experienced massive bleeding. Conclusions: The clinical data indicated that NBT in combination with EBRT produced favorable local control and long-term survival rates for elderly patients with GEJAC, and that the side effects were tolerable. The patient’s age could be used to select the appropriate treatment in an elderly patient.

  1. Long-term results of curative intraluminal high dose rate brachytherapy for endobronchial carcinoma

    Directory of Open Access Journals (Sweden)

    Kawamura Hidemasa

    2012-07-01

    Full Text Available Abstract Background The treatment strategy of central lung tumors is not established. Intraluminal brachytherapy (ILBT is widely used for palliative treatment of endobronchial tumors, however, it is also a promising option for curative treatment with limited data. This study evaluates the results after ILBT for endobronchial carcinoma. Method Sixteen-endobronchial carcinoma of 13 patients treated with ILBT in curative intent for 2000 to 2008 were retrospectively reviewed. ILBT using high dose rate 192 iridium thin wire system was performed with 5 Gy/fraction at mucosal surface. The patient age ranged from 57 to 82 years old with median 75 years old. The 16 lesions consisted of 13 central endobronchial cancers including 7 roentgenographically occult lung cancers and 3 of tracheal cancers. Of them, 10 lesions were treated with ILBT of median 20 Gy combined with external beam radiation therapy of median 45 Gy and 6 lesions were treated with ILBT alone of median 25 Gy. Results Median follow-up time was 32.5 months. Two-year survival rate and local control rate were 92.3% and 86.2%, respectively. Local recurrences were observed in 2 lesions. Three patients died due to lung cancer (1 patient and intercurrent disease (2 patients. Complications greater than grade 2 were not observed except for one grade 3 dyspnea. Conclusions ILBT combined with or without EBRT might be a curative treatment option in inoperable endobronchial carcinoma patients with tolerable complication.

  2. MRI-Guided High–Dose-Rate Intracavitary Brachytherapy for Treatment of Cervical Cancer: The University of Pittsburgh Experience

    Energy Technology Data Exchange (ETDEWEB)

    Gill, Beant S.; Kim, Hayeon; Houser, Christopher J. [Department of Radiation Oncology, Magee-Womens Hospital of University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania (United States); Kelley, Joseph L.; Sukumvanich, Paniti; Edwards, Robert P.; Comerci, John T.; Olawaiye, Alexander B.; Huang, Marilyn; Courtney-Brooks, Madeleine [Department of Gynecologic Oncology, Magee-Womens Hospital of University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania (United States); Beriwal, Sushil, E-mail: beriwals@upmc.edu [Department of Radiation Oncology, Magee-Womens Hospital of University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania (United States)

    2015-03-01

    Purpose: Image-based brachytherapy is increasingly used for gynecologic malignancies. We report early outcomes of magnetic resonance imaging (MRI)-guided brachytherapy. Methods and Materials: Consecutive patient cases with FIGO stage IB1 to IVA cervical cancer treated at a single institution were retrospectively reviewed. All patients received concurrent cisplatin with external beam radiation therapy along with interdigitated high–dose-rate intracavitary brachytherapy. Computed tomography or MRI was completed after each application, the latter acquired for at least 1 fraction. High-risk clinical target volume (HRCTV) and organs at risk were identified by Groupe Européen de Curiethérapie and European SocieTy for Radiotherapy and Oncology guidelines. Doses were converted to equivalent 2-Gy doses (EQD{sub 2}) with planned HRCTV doses of 75 to 85 Gy. Results: From 2007 to 2013, 128 patients, median 52 years of age, were treated. Predominant characteristics included stage IIB disease (58.6%) with a median tumor size of 5 cm, squamous histology (82.8%), and no radiographic nodal involvement (53.1%). Most patients (67.2%) received intensity modulated radiation therapy (IMRT) at a median dose of 45 Gy, followed by a median brachytherapy dose of 27.5 Gy (range, 25-30 Gy) in 5 fractions. At a median follow up of 24.4 months (range, 2.1-77.2 months), estimated 2-year local control, disease-free survival, and cancer-specific survival rates were 91.6%, 81.8%, and 87.6%, respectively. Predictors of local failure included adenocarcinoma histology (P<.01) and clinical response at 3 months (P<.01). Among the adenocarcinoma subset, receiving HRCTV D{sub 90} EQD{sub 2} ≥84 Gy was associated with improved local control (2-year local control rate 100% vs 54.5%, P=.03). Grade 3 or greater gastrointestinal or genitourinary late toxicity occurred at a 2-year actuarial rate of 0.9%. Conclusions: This study constitutes one of the largest reported series of MRI

  3. Assessing patient characteristics and radiation-induced non-targeted effects in vivo for high dose-rate (HDR) brachytherapy.

    Science.gov (United States)

    Pinho, Christine; Timotin, Emilia; Wong, Raimond; Sur, Ranjan K; Hayward, Joseph E; Farrell, Thomas J; Seymour, Colin; Mothersill, Carmel

    2015-01-01

    To test whether blood, urine, and tissue based colony-forming assays are a useful clinical detection tool for assessing fractionated treatment responses and non-targeted radiation effects in bystander cells. To assess patients' responses to radiation treatments, blood serum, urine, and an esophagus explant-based in vivo colony-forming assay were used from oesophageal carcinoma patients. These patients underwent three fractions of high dose rate (HDR) intraluminal brachytherapy (ILBT). Human keratinocyte reporters exposed to blood sera taken after the third fraction of brachytherapy had a significant increase in cloning efficiency compared to baseline samples (p fractions for the blood sera data only. Patient characteristics such as gender had no statistically significant effect (p > 0.05). Large variability was observed among the patients' tissue samples, these colony-forming assays showed no significant changes throughout fractionated brachytherapy (p > 0.05). Large inter-patient variability was found in the urine and tissue based assays, so these techniques were discontinued. However, the simple blood-based assay had much less variability. This technique may have future applications as a biological dosimeter to predict treatment outcome and assess non-targeted radiation effects.

  4. High-dose rate brachytherapy in the treatment of prostate cancer: acute toxicity and biochemical behavior analysis

    International Nuclear Information System (INIS)

    Esteves, Sergio Carlos Barros; Oliveira, Antonio Carlos Zuliani de; Cardoso, Herbeni; Tagawa, Eduardo Komai; Castelo, Roberto; D'Imperio, Marcio

    2006-01-01

    Objective: this study focuses on the biochemical response of the following variables: prostate volume, prostate-specific antigen (PSA) value, Gleason scores, staging, the risk of the disease, and hormone therapy. Objective: in the period between February of 1998 and July of 2001, 46 patients with prostate cancer were treated with radiotherapy, in a combination of teletherapy and high-dose rate (HDR) brachytherapy. The age ranged from 51 to 79 years (averaging 66.4 years). T1c stage was the most frequent one: 30 (65%). The Gleason score was below 7 in 78% of the patients. PSA ranged from 3.4 to 33.3, being below 10 in 39% of the cases. The average prostatic volume was 32.3 cc. Twenty-eight percent of the patients received hormone therapy. Teletherapy dose ranged from 45 to 50.4 Gy, associated to four fractions of 4 Gy of HDR brachytherapy. Results: the follow-up period varied from 6 to 43 months. Four patients missed the follow-up and four died (one due to the disease). Out of the 39 patients that were analyzed, 76% presented a less than 1.5 PSA. None of the analyzed variables were found to be of statistical significance (p > 0.05) regarding biochemical control. Conclusion: the use of HDR brachytherapy was found to be effective in the treatment of prostate cancer and, in this study, the variables considered as prognostic factors did not interfere in the biochemical control. (author)

  5. A mechanical system design of the iridium-192 isotope wire in cervical cancer brachytherapy with medium dose rate

    International Nuclear Information System (INIS)

    Ari Satmoko; Sanda; Tri Harjanto; Atang Susila

    2010-01-01

    In 2010, brachytherapy engineering development activities have a purpose to establish a detailed design of the cervical cancer brachytherapy with medium dose rate. The brachytherapy will use an Iridium-92 source with the emitting radiation of 5 to 10 Curies. The source is wrapped in SS-316 capsule and carried by a SS-316 wire having diameter of about 1 mm dan length of 1800 mm. As part of this activity, the preliminary design of the mechanical drive systems for the isotope source has been developed. The technical specifications for the main components of the mechanical drive system have been successfully determined. This is started by studying the concept design, performing calculations, determining technical specifications, and finally defining the main components. From the evaluation, some components were decided: a stepper motor PK264A1-SG10, needle bearing NKI-10/20, spiral tube in SS316-1/8'' with 120 mm in diameter, rubber-based belts with a width of 20 mm, and aluminium drum with a diameter of 100 mm. Not all components could be identified in detail, especially for the components that do not exist in the marketplace and have to be created ourself Since the main components have been identified, the detailed design step of the mechanical drive systems for the isotope source can be performed. (author)

  6. The mechanical system design of the iridium-192 isotope wire in cervical cancer brachytherapy with medium dose rate

    International Nuclear Information System (INIS)

    Ari Satmoko; Sanda; Tri Harjanto; Atang Susila

    2010-01-01

    In 2010, brachytherapy engineering activities have a purpose to establish a detailed design of the cervical cancer brachytherapy with medium dose rate. The brachytherapy will use an Iridium-92 source with the emiting radiation of 5 to 10 Curies. The source is wrapped in SS-316 capsule and carried by a SS-316 wire having diameter of about 1 mm dan length of 1800 mm. As part of this activity, the preliminary design of the mechanical drive systems for the isotope source has been developed. The technical specifications for the main components of the mechanical drive system have been successfully determined. This is started by studying the concept design, performing calculations, determining technical specifications, and finally defining the main components. From the evaluation, some components were decided: a stepper motor PK264A1-SG10, needle bearing NKI-10/20, spiral tube in SS316-1/8'' with 120 mm in diameter, rubber-based belts with a width of 20 mm, and aluminium drum with a diameter of 100 mm. Not all components could be identified in detail, especially for the components that do not exist in the market place and have to be created ourself. Since the main components have been identified, the detailed design step of the mechanical drive systems for the isotope source can be performed. (author)

  7. Radioablation of liver malignancies with interstitial high-dose-rate brachytherapy. Complications and risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Mohnike, Konrad; Wolf, Steffen; Damm, Robert; Seidensticker, Max; Seidensticker, Ricarda; Fischbach, Frank; Pech, Maciej; Ricke, Jens [Otto-von-Guericke-Universitaet, Klinik fuer Radiologie und Nuklearmedizin, Universitaetsklinikum Magdeburg A.oe.R., Magdeburg (Germany); Peters, Nils; Hass, Peter; Gademann, Guenther [Otto-von-Guericke-Universitaet, Klinik fuer Strahlentherapie, Universitaetsklinikum Magdeburg A.oe.R., Magdeburg (Germany)

    2016-05-15

    To evaluate complications and identify risk factors for adverse events in patients undergoing high-dose-rate interstitial brachytherapy (iBT). Data from 192 patients treated in 343 CT- or MRI-guided interventions from 2006-2009 at our institution were analyzed. In 41 %, the largest tumor treated was ≥ 5 cm, 6 % of the patients had tumors ≥ 10 cm. Prior to iBT, 60 % of the patients had chemotherapy, 22 % liver resection, 19 % thermoablation or transarterial chemoembolization (TACE). Safety was the primary endpoint; survival data were obtained as the secondary endpoints. During follow-up, MRI or CT imaging was performed and clinical and laboratory parameters were obtained. The rate of major complications was below 5 %. Five major bleedings (1.5 %) occurred. The frequency of severe bleeding was significantly higher in patients with advanced liver cirrhosis. One patient developed signs of a nonclassic radiation-induced liver disease. In 3 patients, symptomatic gastrointestinal (GI) ulcers were detected. A dose exposure to the GI wall above 14 Gy/ml was a reliable threshold to predict ulcer formation. A combination of C-reactive protein ≥ 165 mg/l and/or leukocyte count ≥ 12.7 Gpt/l on the second day after the intervention predicted infection (sensitivity 90.0 %; specificity 92.8 %.) Two patients (0.6 %) died within 30 days. Median overall survival after the first liver treatment was 20.1 months for all patients and the local recurrence-free surviving proportion was 89 % after 12 months. Image-guided iBT yields a low rate of major complications and is effective. (orig.) [German] Evaluierung der Komplikationsrate und Identifizierung von Risikofaktoren fuer Komplikationen und Nebenwirkungen bei Patienten mit Lebermalignomen, die mit der hochdosierten interstitiellen Brachytherapie (iBT) behandelt wurden. Von 2006 bis 2009 wurden 192 Patienten in 343 CT- oder MRT-gefuehrten Interventionen behandelt und deren Daten ausgewertet. Der groesste behandelte Tumor war in

  8. High-Dose-Rate Monotherapy: Safe and Effective Brachytherapy for Patients With Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Demanes, D. Jeffrey; Martinez, Alvaro A.; Ghilezan, Michel; Hill, Dennis R.; Schour, Lionel; Brandt, David; Gustafson, Gary

    2011-01-01

    Purpose: High-dose-rate (HDR) brachytherapy used as the only treatment (monotherapy) for early prostate cancer is consistent with current concepts in prostate radiobiology, and the dose is reliably delivered in a prospectively defined anatomic distribution that meets all the requirements for safe and effective therapy. We report the disease control and toxicity of HDR monotherapy from California Endocurietherapy (CET) and William Beaumont Hospital (WBH) in low- and intermediate-risk prostate cancer patients. Methods and Materials: There were 298 patients with localized prostate cancer treated with HDR monotherapy between 1996 and 2005. Two biologically equivalent hypofractionation protocols were used. At CET the dose was 42 Gy in six fractions (two implantations 1 week apart) delivered to a computed tomography–defined planning treatment volume. At WBH the dose was 38 Gy in four fractions (one implantation) based on intraoperative transrectal ultrasound real-time treatment planning. The bladder, urethral, and rectal dose constraints were similar. Toxicity was scored with the National Cancer Institute Common Toxicity Criteria for Adverse Events version 3. Results: The median follow-up time was 5.2 years. The median age of the patients was 63 years, and the median value of the pretreatment prostate-specific antigen was 6.0 ng/mL. The 8-year results were 99% local control, 97% biochemical control (nadir +2), 99% distant metastasis–free survival, 99% cause-specific survival, and 95% overall survival. Toxicity was scored per event, meaning that an individual patient with more than one symptom was represented repeatedly in the morbidity data table. Genitourinary toxicity consisted of 10% transient Grade 2 urinary frequency or urgency and 3% Grade 3 episode of urinary retention. Gastrointestinal toxicity was <1%. Conclusions: High disease control rates and low morbidity demonstrate that HDR monotherapy is safe and effective for patients with localized prostate cancer.

  9. TU-D-201-07: Severity Indication in High Dose Rate Brachytherapy Emergency Response Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Li, K [Associates in Medical Physics, Hagerstown, MD (United States); Rustad, F [Associates In Medical Physics, Lanham, MD (United States)

    2016-06-15

    Purpose: Understanding the corresponding dose to different staff during the High Dose Rate (HDR) Brachytherapy emergency response procedure could help to develop a strategy in efficiency and effective action. In this study, the variation and risk analysis methodology was developed to simulation the HDR emergency response procedure based on severity indicator. Methods: A GammaMedplus iX HDR unit from Varian Medical System was used for this simulation. The emergency response procedure was decomposed based on risk management methods. Severity indexes were used to identify the impact of a risk occurrence on the step including dose to patient and dose to operation staff by varying the time, HDR source activity, distance from the source to patient and staff and the actions. These actions in 7 steps were to press the interrupt button, press emergency shutoff switch, press emergency button on the afterloader keypad, turn emergency hand-crank, remove applicator from the patient, disconnect transfer tube and move afterloader from the patient, and execute emergency surgical recovery. Results: Given the accumulated time in second at the assumed 7 steps were 15, 5, 30, 15, 180, 120, 1800, and the dose rate of HDR source is 10 Ci, the accumulated dose in cGy to patient at 1cm distance were 188, 250, 625, 813, 3063, 4563 and 27063, and the accumulated exposure in rem to operator at outside the vault, 1m and 10cm distance were 0.0, 0.0, 0.1, 0.1, 22.6, 37.6 and 262.6. The variation was determined by the operators in action at different time and distance from the HDR source. Conclusion: The time and dose were estimated for a HDR unit emergency response procedure. It provided information in making optimal decision during the emergency procedure. Further investigation would be to optimize and standardize the responses for other emergency procedure by time-spatial-dose severity function.

  10. Nationwide, Multicenter, Retrospective Study on High-Dose-Rate Brachytherapy as Monotherapy for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yoshioka, Yasuo, E-mail: yoshioka@radonc.med.osaka-u.ac.jp [Department of Radiation Oncology, Osaka University Graduate School of Medicine, Osaka (Japan); Kotsuma, Tadayuki [Department of Radiation Oncology, Osaka National Hospital, Osaka (Japan); Komiya, Akira [Department of Urology, Graduate School of Medicine and Pharmaceutical Sciences for Research, University of Toyama, Toyama (Japan); Department of Urology, Chiba University Hospital, Chiba (Japan); Kariya, Shinji [Department of Radiology, Kochi Medical School, Kochi (Japan); Konishi, Koji [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Nonomura, Norio [Department of Urology, Osaka University Graduate School of Medicine, Osaka (Japan); Ogawa, Kazuhiko [Department of Radiation Oncology, Osaka University Graduate School of Medicine, Osaka (Japan); Tanaka, Eiichi [Department of Radiation Oncology, Osaka National Hospital, Osaka (Japan); Nishimura, Kensaku [Department of Urology, Osaka National Hospital, Osaka (Japan); Fujiuchi, Yasuyoshi; Kitamura, Hiroshi [Department of Urology, Graduate School of Medicine and Pharmaceutical Sciences for Research, University of Toyama, Toyama (Japan); Yamagami, Takuji [Department of Radiology, Kochi Medical School, Kochi (Japan); Yamasaki, Ichiro [Department of Urology, Kochi Medical School, Kochi (Japan); Nishimura, Kazuo [Department of Urology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Teshima, Teruki [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Nakamura, Katsumasa [Department of Radiation Oncology, Hamamatsu University School of Medicine, Shizuoka (Japan); Itami, Jun [Department of Radiation Oncology, National Cancer Center Hospital, Tokyo (Japan)

    2017-04-01

    Purpose: To present, analyze, and discuss results of a nationwide, multicenter, retrospective study on high-dose-rate brachytherapy (HDR-BT) as monotherapy for low-, intermediate-, and high-risk prostate cancer. Methods and Materials: From 1995 through 2013, 524 patients, 73 (14%) with low-risk, 207 (40%) with intermediate-risk, and 244 (47%) with high-risk prostate cancer, were treated with HDR-BT as monotherapy at 5 institutions in Japan. Dose fractionations were 27 Gy/2 fractions for 69 patients (13%), 45.5 Gy/7 fractions for 168 (32%), 49 Gy/7 fractions for 149 (28%), 54 Gy/9 fractions for 130 (25%), and others for 8 (2%). Of these patients, 156 (30%) did not receive androgen deprivation therapy, and 202 patients (39%) did receive androgen deprivation therapy <1 year, 112 (21%) for 1-3 years, and 54 (10%) for >3 years. Median follow-up time was 5.9 years (range, 0.4-18.1 years), with a minimum of 2 years for surviving patients. Results: After 5 years, respective actuarial rates of no biochemical evidence of disease, overall survival, cause-specific survival, and metastasis-free survival for all patients were 92%, 97%, 99%, and 94%. For low/intermediate/high-risk patients, the 5-year no biochemical evidence of disease rates were 95%/94%/89%, the 5-year overall survival rates were 98%/98%/94%, the 5-year cause-specific survival rates were 98%/100%/98%, and the 5-year metastasis-free survival rates were 98%/95%/90%, respectively. The cumulative incidence of late grade 2 to 3 genitourinary toxicity at 5 years was 19%, and that of late grade 3 was 1%. The corresponding incidences of gastrointestinal toxicity were 3% and 0% (0.2%). No grade 4 or 5 of either type of toxicity was detected. Conclusions: The findings of this nationwide, multicenter, retrospective study demonstrate that HDR-BT as monotherapy was safe and effective for all patients with low-, intermediate-, and high-risk prostate cancer.

  11. Clinical result of high-dose rate intraluminal brachytherapy for esophageal carcinoma with a remote afterloading system

    International Nuclear Information System (INIS)

    Fukuda, Haruyuki; Nakajima, Toshifumi; Tada, Takuhito; Tanaka, Masahiro; Tsumura, Masashi; Onoyama, Yasuto

    1992-01-01

    During the period from 1977 through 1987, 105 patients with esophageal carcinoma were radically treated by radiotherapy. Forty-six patients receiving therapy before August 1982 were all treated by external beam therapy alone (Group 1). Since September 1982, 26 patients were treated by external beam therapy alone (Group 2) and 33 patients were treated by high-dose-rate intraluminal brachytherapy with a remote afterloading system combined with external beam therapy (Group 3). Dose of external beam therapy for Group 1, Group 2 and Group 3 patients were 66.7 Gy, 68.7 Gy and 55.9 Gy on the average. The intraluminal brachytherapy was performed with a total dose of 12 Gy consisting of 3 Gy twice a week. Ten of 72 patients (14%) treated by external beam therapy alone achieved complete response, whereas 14 of 33 patients (42%) treated by high-dose-rate intraluminal brachytherapy combined with external beam therapy had complete response. One-, and 3-year survival rates were 36% and 10% in the Group 1, 32% and 12% in the Group 2 and 56% and 36% in the Group 3. For Group 3, good survival rate was obtained in tumorous type and serrated type. Patients with tumor of less than 5 cm in Group 3 had good survival. The data suggest that the high-dose-rate intraluminal bracytherapy prescribed as a boost therapy following external beam therapy is an effective therapy modality for esophageal carcinoma which is of non-circumferential tumor or less than 5 cm. (author)

  12. Dosimetric evaluation of two treatment planning systems for high dose rate brachytherapy applications

    Energy Technology Data Exchange (ETDEWEB)

    Shwetha, Bondel [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India); Ravikumar, Manickam, E-mail: drravikumarm@gmail.com [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India); Supe, Sanjay S.; Sathiyan, Saminathan [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India); Lokesh, Vishwanath [Department of Radiotherapy, Kidwai, Memorial Institute of Oncology, Bangalore (India); Keshava, Subbarao L. [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India)

    2012-04-01

    Various treatment planning systems are used to design plans for the treatment of cervical cancer using high-dose-rate brachytherapy. The purpose of this study was to make a dosimetric comparison of the 2 treatment planning systems from Varian medical systems, namely ABACUS and BrachyVision. The dose distribution of Ir-192 source generated with a single dwell position was compared using ABACUS (version 3.1) and BrachyVision (version 6.5) planning systems. Ten patients with intracavitary applications were planned on both systems using orthogonal radiographs. Doses were calculated at the prescription points (point A, right and left) and reference points RU, LU, RM, LM, bladder, and rectum. For single dwell position, little difference was observed in the doses to points along the perpendicular bisector. The mean difference between ABACUS and BrachyVision for these points was 1.88%. The mean difference in the dose calculated toward the distal end of the cable by ABACUS and BrachyVision was 3.78%, whereas along the proximal end the difference was 19.82%. For the patient case there was approximately 2% difference between ABACUS and BrachyVision planning for dose to the prescription points. The dose difference for the reference points ranged from 0.4-1.5%. For bladder and rectum, the differences were 5.2% and 13.5%, respectively. The dose difference between the rectum points was statistically significant. There is considerable difference between the dose calculations performed by the 2 treatment planning systems. It is seen that these discrepancies are caused by the differences in the calculation methodology adopted by the 2 systems.

  13. Obstructive urination problems after high-dose-rate brachytherapy boost treatment for prostate cancer are avoidable

    International Nuclear Information System (INIS)

    Kragelj, Borut

    2016-01-01

    Aiming at improving treatment individualization in patients with prostate cancer treated with combination of external beam radiotherapy and high-dose-rate brachytherapy to boost the dose to prostate (HDRB-B), the objective was to evaluate factors that have potential impact on obstructive urination problems (OUP) after HDRB-B. In the follow-up study 88 patients consecutively treated with HDRB-B at the Institute of Oncology Ljubljana in the period 2006-2011 were included. The observed outcome was deterioration of OUP (DOUP) during the follow-up period longer than 1 year. Univariate and multivariate relationship analysis between DOUP and potential risk factors (treatment factors, patients’ characteristics) was carried out by using binary logistic regression. ROC curve was constructed on predicted values and the area under the curve (AUC) calculated to assess the performance of the multivariate model. Analysis was carried out on 71 patients who completed 3 years of follow-up. DOUP was noted in 13/71 (18.3%) of them. The results of multivariate analysis showed statistically significant relationship between DOUP and anti-coagulation treatment (OR 4.86, 95% C.I. limits: 1.21-19.61, p = 0.026). Also minimal dose received by 90% of the urethra volume was close to statistical significance (OR = 1.23; 95% C.I. limits: 0.98-1.07, p = 0.099). The value of AUC was 0.755. The study emphasized the relationship between DOUP and anticoagulation treatment, and suggested the multivariate model with fair predictive performance. This model potentially enables a reduction of DOUP after HDRB-B. It supports the belief that further research should be focused on urethral sphincter as a critical structure for OUP

  14. Second salvage high-dose-rate brachytherapy for radiorecurrent prostate cancer

    Directory of Open Access Journals (Sweden)

    Metha Maenhout

    2017-04-01

    Full Text Available Purpose : Salvage treatments for localized radiorecurrent prostate cancer can be performed safely when a focal and image guided approach is used. Due to the low toxicity, the opportunity exists to investigate a second salvage treatment when a second locally recurrent prostate cancer occurs. Here, we describe a second salvage treatment procedure of 4 patients. Material and methods : Four patients with a pathologically proven second local recurrence were treated in an outpatient magnetic resonance imaging (MRI-guided setting with a single fraction of 19 Gy focal high-dose-rate brachytherapy (HDR-BT. Delineation was performed using choline-PET-CT or a 68Ga-PSMA PET in combination with multiparametric 3 Tesla MRI in all four patients. Toxicity was measured using common toxicity criteria for adverse events (CTCAE version 4.0. Results : With a median follow-up of 12 months (range, 6-15, there were 2 patients with biochemical recurrence as defined by the Phoenix-definition. There were no patients with grade 3 or more toxicity. In all second salvage HDR-BT treatments, the constraints for rectum, bladder, and urethra were met. Median treatment volume (GTV was 4.8 cc (range, 1.9-6.6 cc. A median of 8 catheters (range, 6-9 were used, and the median dose to the treatment volume (GTV was a D95: 19.3 Gy (SD 15.5-19.4 Gy. Conclusions : Second focal salvage MRI-guided HDR-BT for a select group of patients with a second locally recurrent prostate cancer is feasible. There was no grade 3 or more acute toxicity for these four patients.

  15. Quality of Life of Oral Cancer Patients After Low-Dose-Rate Interstitial Brachytherapy

    International Nuclear Information System (INIS)

    Yoshimura, Ryo-ichi; Shibuya, Hitoshi; Miura, Masahiko; Watanabe, Hiroshi; Ayukawa, Fumio; Hayashi, Keiji; Toda, Kazuma

    2009-01-01

    Purpose: To assess the quality of life (QOL) of oral cancer patients treated with low-dose-rate interstitial brachytherapy (LDR-BT) alone. Methods and Materials: Between June 2005 and July 2006, a total of 56 patients with oral cancer were enrolled in this prospective study. QOL was assessed by means of the core questionnaire and head and neck questionnaire module of the European Organization for Research and Treatment of Cancer (EORTC Quality of Life Questionnaire-Core 30 [QLQ-C30] and QLQ Head and Neck 35 [H and N35]). The questionnaires were distributed to the patients before the start of treatment and 3 months, 6 months, and 12 months after the start of LDR-BT. Results: It was possible to analyze the results for 20 of the initial 56 patients because they did not experience metastasis or recurrence during this study. No functions or symptoms asked about in the QLQ-C30 deteriorated during the first year. The emotional function score steadily and significantly increased. No symptoms in the QLQ-H and N35 significantly deteriorated. The scores for pain, trouble with social eating, and weight loss on the QLQ-H and N35 steadily and significantly decreased. Age, gender, and LDR-BT source had no effect on the change in QOL during the first year, but T-stage significantly affected the change in global health status, tumor site affected the changes in swallowing, sensory problems, sticky saliva, and complications affected the changes in pain, swallowing, and mouth opening. Conclusions: QOL of oral cancer patients treated with LDR-BT is high. However, tumor stage, tumor site, and complications affected the changes in a few functions and symptoms during the first year

  16. Dosimetric evaluation of two treatment planning systems for high dose rate brachytherapy applications.

    Science.gov (United States)

    Shwetha, Bondel; Ravikumar, Manickam; Supe, Sanjay S; Sathiyan, Saminathan; Lokesh, Vishwanath; Keshava, Subbarao L

    2012-01-01

    Various treatment planning systems are used to design plans for the treatment of cervical cancer using high-dose-rate brachytherapy. The purpose of this study was to make a dosimetric comparison of the 2 treatment planning systems from Varian medical systems, namely ABACUS and BrachyVision. The dose distribution of Ir-192 source generated with a single dwell position was compared using ABACUS (version 3.1) and BrachyVision (version 6.5) planning systems. Ten patients with intracavitary applications were planned on both systems using orthogonal radiographs. Doses were calculated at the prescription points (point A, right and left) and reference points RU, LU, RM, LM, bladder, and rectum. For single dwell position, little difference was observed in the doses to points along the perpendicular bisector. The mean difference between ABACUS and BrachyVision for these points was 1.88%. The mean difference in the dose calculated toward the distal end of the cable by ABACUS and BrachyVision was 3.78%, whereas along the proximal end the difference was 19.82%. For the patient case there was approximately 2% difference between ABACUS and BrachyVision planning for dose to the prescription points. The dose difference for the reference points ranged from 0.4-1.5%. For bladder and rectum, the differences were 5.2% and 13.5%, respectively. The dose difference between the rectum points was statistically significant. There is considerable difference between the dose calculations performed by the 2 treatment planning systems. It is seen that these discrepancies are caused by the differences in the calculation methodology adopted by the 2 systems. Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  17. Three-dimensional image-based high-dose-rate interstitial brachytherapy for mobile tongue cancer

    International Nuclear Information System (INIS)

    Yoshida, Ken; Takenaka, Tadashi; Akiyama, Hironori

    2014-01-01

    To investigate the influence of a 3D image-based treatment-planning method for high-dose-rate interstitial brachytherapy (HDR-ISBT) for mobile tongue cancer, we analyzed dose–volume histogram results for the clinical target volume (CTV) and the mandible. Between October 2010 and November 2011, one and four patients having T2 and T3 tumors, respectively, were treated with HDR-ISBT. Multiplane implantation using 9–15 treatment applicators was performed. Lugol's iodine staining, metal markers, ultrasonography, and magnetic resonance imaging were used to identify the contours of the gross tumor volume (defined as the CTV). The results of the image-based treatment plan were compared with those of the conventional simulated plan on the basis of a reference point 5 mm from the applicator position. The mean D90(CTV) and V100(CTV) were 112% of the prescribed dose (PD) and 98.1%PD, respectively, for the image-based plan, and 113%PD and 97.2%PD, respectively, for the conventional plan. The median CTV ref /V ref was 0.23 for the image-based plan and 0.16 for the conventional plan (P = 0.01). The mean D 0.1 cm 3 (mandible), D 1 cm 3 (mandible), and D 2 cm 3 (mandible) were 80.1%PD, 62.5%PD, and 55.7%PD, respectively, for the image-based plan, and 109.1%PD (P = 0.02), 82.4%PD (P = 0.005), and 74%PD (P = 0.004), respectively, for the conventional plan). Image-based treatment planning may achieve high-conformity radiotherapy for the CTV and decrease irradiated doses to the mandible. (author)

  18. Pulsed Dose Rate (PDR - BT) brachytherapy in treatment of breast cancer

    International Nuclear Information System (INIS)

    Skowronek, J.

    2007-01-01

    Breast conserving surgery (BCS) and radiotherapy (EBRT) of the conserved breast became widely accepted in the last decades for the treatment of early invasive breast cancer. The standard technique of RT after breast conservation is to treat the whole breast up to a total dose of 45 to 50 Gy. Initially brachytherapy for breast cancer was used in addition of external radiation to boost a portion of the breast to higher doses. However, over the past 10 years, the application of brachytherapy in breast cancer has changed. In early stage breast cancer, research has shown that the area that requires radiation treatment to prevent the cancer from returning is the breast tissue that surrounds the area where the initial cancer was removed. Because this typically includes only a part of the breast, brachytherapy is now being used to treat the targeted portion of the breast and as a result allows accelerated delivery of the radiation dose so that treatment is completed in four to five days. Another indications for PDR - BT as a part of treatment in locally advanced breast cancer or as a palliative treatment are discussed in the paper, too. Preliminary results with PDR - BT boost technique are promising. However, more experience and longer follow-up are required to define whether these methods might improve local tumor control for breast cancer patients. In this article the current status, indications, technical aspects and published results of PDR brachytherapy (PDR - BT) in breast cancer treatment are reviewed. (author)

  19. Invariance and inconsistency in utility ratings.

    Science.gov (United States)

    Bravata, Dena M; Nelson, Lorene M; Garber, Alan M; Goldstein, Mary K

    2005-01-01

    To assess utilities of composite health states for dependence in activities of daily living (ADLs) for invariance (i.e., when subjects provide a utility of 1 for all health states) and order inconsistency (i.e., when subjects order their utilities such that their utility for a combination of ADL dependencies is greater than their utility for any subset of the combination). Each of the 400 subjects, age 65 y and older, enrolled in one of several regional medical centers of the Kaiser Permanente Medical Care Program of Northern California and provided standard-gamble utilities for single ADL dependencies (e.g., bathing, dressing, continence) and for dependence in 8 other combinations of ADL dependencies. For order-inconsistent responses, the authors calculated the maximum magnitude of inconsistency as the maximum difference between the utility for the combined ADL dependence health state and that of its inconsistent subset. A total of 76 subjects (19%) gave a utility of 1.0 for all health states presented to them; 19 (5%) gave the same utility other than 1.0 for all health states; 130 (33%) gave at least 1 utility Invariance was associated with a Mini-Mental Status Examination score invariant (0.88 [0.24]) was higher than among inconsistent subjects (0.80 [0.27]; P = 0.01). Invariance and order inconsistencies in utility ratings for complex health states occur frequently. Utilities of consistent subjects may differ from those of inconsistent subjects. Utility assessments should attempt to measure and report these patterns.

  20. Monte Carlo dosimetric characterization of the Flexisource Co-60 high-dose-rate brachytherapy source using PENELOPE.

    Science.gov (United States)

    Almansa, Julio F; Guerrero, Rafael; Torres, Javier; Lallena, Antonio M

    60 Co sources have been commercialized as an alternative to 192 Ir sources for high-dose-rate (HDR) brachytherapy. One of them is the Flexisource Co-60 HDR source manufactured by Elekta. The only available dosimetric characterization of this source is that of Vijande et al. [J Contemp Brachytherapy 2012; 4:34-44], whose results were not included in the AAPM/ESTRO consensus document. In that work, the dosimetric quantities were calculated as averages of the results obtained with the Geant4 and PENELOPE Monte Carlo (MC) codes, though for other sources, significant differences have been quoted between the values obtained with these two codes. The aim of this work is to perform the dosimetric characterization of the Flexisource Co-60 HDR source using PENELOPE. The MC simulation code PENELOPE (v. 2014) has been used. Following the recommendations of the AAPM/ESTRO report, the radial dose function, the anisotropy function, the air-kerma strength, the dose rate constant, and the absorbed dose rate in water have been calculated. The results we have obtained exceed those of Vijande et al. In particular, the absorbed dose rate constant is ∼0.85% larger. A similar difference is also found in the other dosimetric quantities. The effect of the electrons emitted in the decay of 60 Co, usually neglected in this kind of simulations, is significant up to the distances of 0.25 cm from the source. The systematic and significant differences we have found between PENELOPE results and the average values found by Vijande et al. point out that the dosimetric characterizations carried out with the various MC codes should be provided independently. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  1. Optimal bladder filling during high-dose-rate intracavitary brachytherapy for cervical cancer: a dosimetric study

    Directory of Open Access Journals (Sweden)

    Umesh Mahantshetty

    2017-04-01

    Full Text Available Purpose: The aim of this study is to compare 3D dose volume histogram (DVH parameters of bladder and other organs at risk with different bladder filling protocol during high-dose-rate intracavitary brachytherapy (HDR-ICBT in cervical cancer, and to find optimized bladder volume. Material and methods : This dosimetric study was completed with 21 patients who underwent HDR-ICBT with computed tomography/magnetic resonance compatible applicator as a routine treatment. Computed tomography planning was done for each patient with bladder emptied (series 1, after 50 ml (series 2, and 100 ml (series 3 bladder filling with a saline infusion through the bladder catheter. Contouring was done on the Eclipse Planning System. 7 Gy to point A was prescribed with the standard loading patterns. Various 3D DVH parameters including 0.1 cc, 1 cc, 2 cc doses and mean doses to the OAR’s were noted. Paired t-test was performed. Results : The mean (± SD bladder volume was 64.5 (± 25 cc, 116.2 (± 28 cc, and 172.9 (± 29 cc, for series 1, 2, and 3, respectively. The 0.1 cm 3 ,1 cm 3 , 2 cm 3 mean bladder doses for series 1, series 2, and series 3 were 9.28 ± 2.27 Gy, 7.38 ± 1.72 Gy, 6.58 ± 1.58 Gy; 9.39 ± 2.28 Gy, 7.85 ± 1.85 Gy, 7.05 ± 1.59 Gy, and 10.09 ± 2.46 Gy, 8.33 ± 1.75 Gy, 7.6 ± 1.55 Gy, respectively. However, there was a trend towards higher bladder doses in series 3. Similarly, for small bowel dose 0.1 cm 3 , 1 cm 3 , and 2 cm 3 in series 1, 2, and 3 were 5.44 ± 2.2 Gy, 4.41 ± 1.84 Gy, 4 ± 1.69 Gy; 4.57 ± 2.89 Gy, 3.78 ± 2.21 Gy, 3.35 ± 2.02 Gy, and 4.09 ± 2.38 Gy, 3.26 ± 1.8 Gy, 3.05 ± 1.58 Gy. Significant increase in small bowel dose in empty bladder (series 1 compared to full bladder (series 3 (p = 0.03 was noted. However, the rectal and sigmoid doses were not significantly affected with either series. Conclusions : Bladder filling protocol with 50 ml and 100 ml was well tolerated and achieved a reasonably reproducible bladder volume

  2. Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer

    Directory of Open Access Journals (Sweden)

    Y. Sobita Devi

    2011-12-01

    Full Text Available Purpose: The aim of this study is to evaluate the decrease of biological equivalent dose and its correlation withlocal/loco-regional control of tumour in the treatment of cervical cancer when the strength of the Ir-192 high dose rate(HDR brachytherapy (BT source is reduced to single, double and triple half life in relation to original strength of10 Ci (~ 4.081 cGy x m2 x h–1. Material and methods: A retrospective study was carried out on 52 cervical cancer patients with stage II and IIItreated with fractionated HDR-BT following external beam radiation therapy (EBRT. International Commission onRadiation Units and Measurement (ICRU points were defined according to ICRU Report 38, using two orthogonal radiographimages taken by Simulator (Simulix HQ. Biologically effective dose (BED was calculated at point A for diffe -rent Ir-192 source strength and its possible correlation with local/loco-regional tumour control was discussed. Result: The increase of treatment time per fraction of dose due to the fall of dose rate especially in HDR-BT of cervicalcancer results in reduction in BED of 2.59%, 7.02% and 13.68% with single, double and triple half life reduction ofsource strength, respectively. The probabilities of disease recurrence (local/loco-regional within 26 months are expectedas 0.12, 0.12, 0.16, 0.39 and 0.80 for source strength of 4.081, 2.041, 1.020, 0.510 and 0.347 cGy x m2 x h–1, respectively.The percentages of dose increase required to maintain the same BED with respect to initial BED were estimated as1.71, 5.00, 11.00 and 15.86 for the dose rate of 24.7, 12.4, 6.2 and 4.2 Gy/hr at point A, respectively. Conclusions: This retrospective study of cervical cancer patients treated with HDR-BT at different Ir-192 sourcestrength shows reduction in disease free survival according to the increase in treatment time duration per fraction.The probable result could be associated with the decrease of biological equivalent dose to point A. Clinical

  3. Computed Tomography–Planned High-Dose-Rate Brachytherapy for Treating Uterine Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zolciak-Siwinska, Agnieszka, E-mail: agnieszka.zolciak@wp.pl [Department of Brachytherapy, The Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Warsaw (Poland); Gruszczynska, Ewelina; Bijok, Michal [Department of Medical Physics, The Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Warsaw (Poland); Jonska-Gmyrek, Joanna [Department of Teleradiotherapy, The Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Warsaw (Poland); Dabkowski, Mateusz [Department of Brachytherapy, The Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Warsaw (Poland); Staniaszek, Jagna [Department of Teleradiotherapy, The Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Warsaw (Poland); Michalski, Wojciech [Department of Clinical Trials and Biostatistics, The Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Warsaw (Poland); Kowalczyk, Adam; Milanowska, Katarzyna [Department of Medical Physics, The Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Warsaw (Poland)

    2016-09-01

    Purpose: To evaluate the long-term results of computed tomography (CT)–planned high-dose-rate (HDR) brachytherapy (BT) for treating cervical cancer patients. Methods and Materials: CT-planned HDR BT was performed according to the adapted Group European de Curietherapie-European Society for Therapeutic Radiology and Oncology (GEC-ESTRO) recommendations in 216 consecutive patients with locally advanced cervical cancer, International Federation of Gynecology and Obstetrics (FIGO) stage IB to IVA, who were treated with conformal external beam radiation therapy and concomitant chemotherapy. We analyzed outcomes and late side effects evaluated according to the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer and Subjective, Objective, Management, Analysis evaluation scoring system and compared them with the results from a historical group. Results: The median age was 56 years (range, 32-83 years). The median follow-up time for living patients was 52 months (range 37-63 months). The 5-year cumulative incidence function for the local recurrence rate for patients with FIGO II and III was 5.5% and 20%, respectively (P=.001). The 5-year rates of overall survival (OS) and disease-free survival (DFS) were 66.4% and 58.5%, respectively. The relative risk of failure for OS and DFS for FIGO III in relation to FIGO II was 2.24 (P=.003) and 2.6 (P=.000) and for lymph node enlargement was 2.3 (P=.002) and 2 (P=.006), respectively. In 2 patients, rectovaginal fistula occurred, and in 1 patient, vesicovaginal fistula occurred without local progression. Comparison of late adverse effects in patients treated according to the GEC-ESTRO recommendations and in the historical group revealed a reduction in fistula formation of 59% and also a reduction in rectal grade 3 to 4 late toxicity of >59%. Conclusions: This is the largest report with mature data of CT-planned BT HDR for the treatment of cervical cancer with good local control and

  4. Positional variation of applicators during low dose rate intracavitary brachytherapy for cervical cancer: a prospective study

    Directory of Open Access Journals (Sweden)

    Arul Ponni

    2010-10-01

    Full Text Available Purpose: In order to know the effect of variation in position of applicators to the dose received by the tumor volume, critical organs such as rectum and bladder and the correlation of variation on the clinical outcome.Material and methods: 36 patients with histologically proven cervical cancer, undergoing intracavitary brachythe - rapy (ICBT from October 2005 to December 2006 were the subjects of the study. Two pairs of orthogonal X-ray films were taken: one prior to loading of sources and the other after removal of sources. These patients were followed up as per the RTOG criteria.Results: The median duration of insertion was 25 hours with a median follow up period of 6.7 months. The translational variation of the applicator position for all patients was 3 mm and 1 mm (2 SD, respectively, in the patient’s lateral and antero-posterior direction. The rotational variation was 3 and 4 degrees (2 SD in the patient’s transverse and sagittal planes. Detailed analysis of source movement showed following changes in median dose: point A: 14%, point B: 2%, point P: 1%, Rectum 1: 3.5%, Rectum 2: 4% and Bladder: 9.1%. The incidence of rectal toxicity was 6/36(16.7% and that of bladder was 1/36 (2.8%. When the variables were grouped to evaluate the relationship, our study showed statistically significant relationship between: R2 and rectal toxicity (p value: 0.002, point A and rectal toxicity (Pearson: 0.792, lateral displacement/anteroposterior displacement and rectal toxicity (p value: 0.012/0.003, beta angle and R2 (p value: 0.002.Conclusions: The geometric relationships between the ICBT applicators and the critical structures vary during the course of low dose rate brachytherapy. Source movement does result in significant dose alterations in terms of increased rate of complications, but its impact on cure rates needs to be studied in the future.

  5. Concomitant cervical and transperineal parametrial high-dose-rate brachytherapy boost for locally advanced cervical cancer

    Directory of Open Access Journals (Sweden)

    Caroline Bailleux

    2016-01-01

    Full Text Available Purpose: There is no consensus for parametrial boost technic while both transvaginal and transperineal approaches are discussed. A prototype was developed consisting of a perineal template, allowing transperineal needle insertion. This study analyzed acute toxicity of concomitant cervical and transperineal parametrial high-dose-rate brachytherapy (HDRB boost for locally advanced cervical cancer. Material and methods: From 01.2011 to 12.2014, 33 patients (pts presenting a locally advanced cervical cancer with parametrial invasion were treated. After the first course of external beam radiation therapy with cisplatinum, HDRB was performed combining endocavitary and interstitial technique for cervical and parametrial disease. Post-operative delineation (CTV, bladder, rectum, sigmoid and planification were based on CT-scan/MRI. HDRB was delivered in 3-5 fractions over 2-3 consecutive days. Acute toxicities occurring within 6 months after HDRB were retrospectively reviewed. Results: Median age was 56.4 years (27-79. Clinical stages were: T2b = 23 pts (69.7%, T3a = 1 pt (3%, T3b = 6 pts (18.2%, and T4a = 3 pts (9.1%. Median HDRB prescribed dose was 21 Gy (21-27. Median CTVCT (16 pts and HR-CTV MRI (17 pts were 52.6 cc (28.5-74.3, 31.9 cc (17.1-58, respectively. Median EQD2αβ10 for D90CTV and D90HR-CTV were 82.9 Gy (78.2-96.5, 84.8 Gy (80.6-91.4, respectively. Median EQD2αβ3 (CT/MRI for D2cc bladder, rectum and sigmoid were 75.5 Gy (66.6-90.9, 64.4 Gy (51.9-77.4, and 60.4 Gy (50.9-81.1, respectively. Median follow-up was 14 months (ranged 6-51. Among the 24 pts with MFU = 24 months, 2-year LRFS rate, RRFS, and OS were 86.8%, 88.8%, and 94.1%, respectively. The rates of acute genitourinary and gastrointestinal toxicities were 36% (G1 dysuria = 8 pts, G2 infection = 2 pt, G3 infection = 2 pts, and 27% (G1 diarrhea = 9 pts, respectively. One patient presented vaginal bleeding at the time of applicator withdrawal (G3-blood transfusion; no bleeding was

  6. Endoluminal high dose rate brachytherapy in the treatment of primary and recurrent bronchogenic tree malignancies

    Directory of Open Access Journals (Sweden)

    Maria Fortunato

    2009-03-01

    Full Text Available Introduction: Locally advanced tumours as the initial form of presentation of tumours in the bronchial tree are not a rare event. Bronchogenic recurrence is frequent in the natural history of some tumours. The choice of therapeutic options from the raft available depends on such variables as initial therapy, place of recurrence, symptoms and patient's physical status. Aim: To demonstrate the advantages of endoluminal brachytherapy (EBT with high dose rate (HDR in primary and recurrent tumour of the bronchial tree. Material and methods: A retrospective study of seven patients (pts with primary tumours of the colon, trachea and lung. Tracheobronchial recurrence (trachea, two pts, bronchus, five pts occurred betweenMarch 2003 and September 2004. Patients under-went EBT with HDR for primary or recurrent therapy in association with external radiotherapy, laser therapy and chemotherapy with palliative or curative intention. EBT with HDR doses of 5 to 7 Gy in 2 to 4 fractions at 1 cm from the source axis were given. Treatment included endoluminal application of Ir192 with a French 6 catheter. Results: There was symptomatic relief related to reduction of tumour in six of the seven patients treated. In one of the six patients studied, there was progression of the local disease between the second and third fractions of the treatment (obstruction of the trachea. In a mean follow up of 17 (2-40 months between EBT and this study, three patients are alive, one has no evidence of disease while two have had bronchial recurrence, four patients have died, one after massive haemoptysis and three due to disease progression. Discussion and conclusions: Patients undergoing brachytherapy for symptomatic primary tumours or endobronchial recurrence show good tolerance, important symptom relief and improved quality of life. Despite the small size of our sample, it is clear that EBT with HDR plays an important role in the palliative/curative treatment of these patients

  7. High-dose-rate brachytherapy as salvage modality for locally recurrent prostate cancer after definitive radiotherapy. A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Chatzikonstantinou, Georgios; Zamboglou, Nikolaos; Roedel, Claus; Tselis, Nikolaos [J.W. Goethe University of Frankfurt, Department of Radiotherapy and Oncology, Frankfurt am Main (Germany); Zoga, Eleni [Sana Klinikum Offenbach, Department of Radiotherapy and Oncology, Offenbach am Main (Germany); Strouthos, Iosif [Medical Center - University of Freiburg, Department of Radiotherapy and Oncology, University of Freiburg, Freiburg (Germany); Butt, Saeed Ahmed [Sana Klinikum Offenbach, Department of Medical Physics and Engineering, Offenbach am Main (Germany)

    2017-09-15

    To review the current status of interstitial high-dose-rate brachytherapy as a salvage modality (sHDR BRT) for locally recurrent prostate cancer after definitive radiotherapy (RT). A literature search was performed in PubMed using ''high-dose-rate, brachytherapy, prostate cancer, salvage'' as search terms. In all, 51 search results published between 2000 and 2016 were identified. Data tables were generated and summary descriptions created. The main outcome parameters used were biochemical control (BC) and toxicity scores. Eleven publications reported clinical outcome and toxicity with follow-up ranging from 4-191 months. A variety of dose and fractionation schedules were described, including 19.0 Gy in 2 fractions up to 42.0 Gy in 6 fractions. The 5-year BC ranged from 18-77%. Late grade 3 genitourinary and gastrointestinal toxicity was 0-32% and 0-5.1%, respectively. sHDR BRT appears as safe and effective salvage modality for the reirradiation of locally recurrent prostate cancer after definitive RT. (orig.) [German] Zusammenfassende Darstellung relevanter Literatur zur interstitiellen High-Dose-Rate-Brachytherapie als Salvage-Modalitaet (sHDR-BRT) bei der Behandlung des lokal rezidivierten Prostatakarzinoms nach vorausgegangener definitiver Radiotherapie (RT). In der PubMed-Datenbank wurde eine Literaturrecherche mit den Suchbegriffen ''high-dose-rate, brachytherapy, prostate cancer, salvage'' durchgefuehrt. Zwischen den Jahren 2000 und 2016 wurden 51 Publikationen identifiziert. Die biochemische Kontrolle (BC) sowie das assoziierte Toxizitaetsprofil waren onkologische Hauptpunkte in der Analyse der beruecksichtigten Literatur. Von onkologischen Ergebnissen und Toxizitaeten berichteten 11 Publikationen bei einer medianen Nachbeobachtungszeit von 4-191 Monaten. Eine Variabilitaet von Dosis- und Fraktionierungsregimen wurde beschrieben mit totalen physikalischen Dosen von 19,0 Gy in 2 Fraktionen bis zu 42,0 Gy in 6 Fraktionen

  8. Evaluation of failure modes of computerized planning phase of interstitial implants with high dose rate brachytherapy using HFMEA

    International Nuclear Information System (INIS)

    Biazotto, Bruna; Tokarski, Marcio

    2014-01-01

    This paper evaluates the failure modes of the computerized planning step in interstitial implants with high dose rate brachytherapy. The prospective tool of risk management Health Care Failure Mode and Effects Analysis (HFMEA) was used. Twelve subprocesses were identified, and 33 failure modes of which 21 justified new safety actions, and 9 of them were intolerable risks. The method proved itself useful in identifying failure modes, but laborious and subjective in their assessment. The main risks were due to human factors, which require training and commitment of management to their mitigation. (author)

  9. MO-B-BRC-01: Introduction [Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Prisciandaro, J. [University of Michigan (United States)

    2016-06-15

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

  10. Inquiry and recommendations on the optimization methods in pulsed rate gynecology brachytherapy

    International Nuclear Information System (INIS)

    Metayer, Y.M.; Peiffer, D.P.; Malet, C.; Meyer, P.; Bellec, J.; Chemin, A.

    2006-01-01

    In the frame of the S.T.I.C. ( program of helper to expensive innovative techniques) called 'Use of the gynecology pulsed brachytherapy with optimization of the dose distribution and three dimensional dosimetry' an inquiry has been realised near 20 centers participating to the program. It bears on the practices, the modalities of imaging, the optimization methods and the quality control that is associated. The S.T.I.C. allows to the teams to concentrate their efforts on a modality in brachytherapy. The experience sharing between the centers allows to accelerate the passage to a three dimensional brachytherapy with optimization. The superiority of MRI for the volume description lead the teams to generalize its access, the difficulty of sources locating stays a brake to its generalisation, a synthesis on the methods used are ongoing. It is to notice the absence of use of dosimetry index and common rules of quality control for the dose distribution. The use of Kerma of the application should be generalised. (N.C.)

  11. High-dose-rate intracavitary brachytherapy in the management of cervical and vaginal intraepithelial neoplasia

    International Nuclear Information System (INIS)

    Ogino, Ichiro; Kitamura, Tatsuo; Okajima, Hiroyuki; Matsubara, Sho

    1998-01-01

    Purpose: To assess the effectiveness of high-dose rate intracavitary brachytherapy (HDR-ICR) in patients with grade 3 cervical intraepithelial neoplasia (CIN-3) and grade 3 vaginal intraepithelial neoplasia (VAIN-3). Methods and Materials: This was a retrospective analysis in 20 patients with CIN-3 (n = 14) or VAIN-3 (n = 6), average age 61.9 years, managed with HDR-ICR at Kanagawa Cancer Center. Two patients with CIN-3 with microinvasive foci and 11 other patients with CIN-3 were treated with HDR-ICR for cervical lesions. Six patients with CIN-3 after hysterectomy received HDR-ICR for recurrent or residual VAIN-3 lesions. One patient received radiation therapy for both CIN-3 and VAIN-3 lesions. All these patients but one were postmenopausal. Results: Seventeen patients were treated with HDR-ICR alone, and three with combined external radiation therapy. The dose was calculated at Point A located 2 cm superior to the external os and 2 cm lateral to the axis of the intrauterine tube for intact uterus. For lesions of the vaginal stump, the dose was calculated at a point 1 cm superior to the vaginal apex or 1 cm beyond vaginal mucosa. In the 14 patients treated for CIN-3 lesions, the mean total dose of HDR-ICR was 26.1 Gy (range 20-30). Six patients received HDR-ICR for VAIN-3 lesions with mean dose of 23.3 Gy (range 15-30). At follow-up (mean 90.5 months; range 13-153), 14 patients were alive and 6 had died owing to nonmalignant intercurrent disease. No patient developed recurrent disease. Rectal bleeding occurred in three patients, but this symptom subsided spontaneously. Moderate and severe vaginal reactions were noted in two patients, in whom the treatment had included the entire vagina. Conclusions: HDR-ICR can be employed as the primary management strategy for postmenopausal women with CIN-3. In intraepithelial neoplasia involving the vaginal wall after hysterectomy, HDR-ICR should be considered as an alternative to total vaginectomy

  12. High Dose Rate Brachytherapy in Two 9 Gy Fractions in the Treatment of Locally Advanced Cervical Cancer - a South Indian Institutional Experience.

    Science.gov (United States)

    Ghosh, Saptarshi; Rao, Pamidimukkala Bramhananda; Kotne, Sivasankar

    2015-01-01

    Although 3D image based brachytherapy is currently the standard of treatment in cervical cancer, most of the centres in developing countries still practice orthogonal intracavitary brachytherapy due to financial constraints. The quest for optimum dose and fractionation schedule in high dose rate (HDR) intracavitary brachytherapy (ICBT) is still ongoing. While the American Brachytherapy Society recommends four to eight fractions of each less than 7.5 Gy, there are some studies demonstrating similar efficacy and comparable toxicity with higher doses per fraction. To assess the treatment efficacy and late complications of HDR ICBT with 9 Gy per fraction in two fractions. This is a prospective institutional study in Southern India carried on from 1st June 2012 to 31st July 2014. In this period, 76 patients of cervical cancer satisfying our inclusion criteria were treated with concurrent chemo-radiation following ICBT with 9 Gy per fraction in two fractions, five to seven days apart. The median follow-up period in the study was 24 months (range 10.6 - 31.2 months). The 2 year actuarial local control rate, disease-free survival and overall survival were 88.1%, 84.2% and 81.8% respectively. Although 38.2% patients suffered from late toxicity, only 3 patients had grade III late toxicity. In our experience, HDR brachytherapy with 9 Gy per fraction in two fractions is an effective dose fractionation for the treatment of cervical cancer with acceptable toxicity.

  13. Genitourinary Toxicity After High-Dose-Rate (HDR) Brachytherapy Combined With Hypofractionated External Beam Radiotherapy for Localized Prostate Cancer: An Analysis to Determine the Correlation Between Dose-Volume Histogram Parameters in HDR Brachytherapy and Severity of Toxicity

    International Nuclear Information System (INIS)

    Ishiyama, Hiromichi; Kitano, Masashi; Satoh, Takefumi; Kotani, Shouko; Uemae, Mineko; Matsumoto, Kazumasa; Okusa, Hiroshi; Tabata, Ken-ichi; Baba, Shiro; Hayakawa, Kazushige

    2009-01-01

    Purpose: To evaluate the severity of genitourinary (GU) toxicity in high-dose-rate (HDR) brachytherapy combined with hypofractionated external beam radiotherapy (EBRT) for prostate cancer and to explore factors that might affect the severity of GU toxicity. Methods and Materials: A total of 100 Japanese men with prostate cancer underwent 192 Ir HDR brachytherapy combined with hypofractionated EBRT. Mean (SD) dose to 90% of the planning target volume was 6.3 (0.7) Gy per fraction of HDR. After 5 fractions of HDR treatment, EBRT with 10 fractions of 3 Gy was administrated. The urethral volume receiving 1-15 Gy per fraction in HDR brachytherapy (V1-V15) and the dose to at least 5-100% of urethral volume in HDR brachytherapy (D5-D100) were compared between patients with Grade 3 toxicity and those with Grade 0-2 toxicity. Prostate volume, patient age, and International Prostate Symptom Score were also compared between the two groups. Results: Of the 100 patients, 6 displayed Grade 3 acute GU toxicity, and 12 displayed Grade 3 late GU toxicity. Regarding acute GU toxicity, values of V1, V2, V3, and V4 were significantly higher in patients with Grade 3 toxicity than in those with Grade 0-2 toxicity. Regarding late GU toxicity, values of D70, D80, V12, and V13 were significantly higher in patients with Grade 3 toxicity than in those with Grade 0-2 toxicity. Conclusions: The severity of GU toxicity in HDR brachytherapy combined with hypofractionated EBRT for prostate cancer was relatively high. The volume of prostatic urethra was associated with grade of acute GU toxicity, and urethral dose was associated with grade of late GU toxicity.

  14. Adjuvant high-dose-rate brachytherapy after external beam radiotherapy in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Oezyar, Enis; Yildz, Ferah; Akyol, Fadil H.; Atahan, I. Lale

    2002-01-01

    Purpose: To compare the local control and survival rates obtained with either external beam radiation therapy (ERT) and adjuvant high-dose-rate (HDR) brachytherapy (BRT) or ERT alone in patients with nasopharyngeal cancer. Methods and Materials: Between December 1993 and December 1999, 144 patients (106 male, 38 female) with the diagnosis of nasopharyngeal cancer were treated with either ERT and adjuvant HDR BRT (Group A) or ERT alone (Group B) at our department. BRT was not applied in 38 patients for the following reasons: (1) Unit was unavailable (n=13), (2) Patient was younger than 18 years (n=17), (3) Patient received accelerated hyperfractionated ERT (n=6), and (4) Patient refused BRT (n=2). The median age for whole group was 43 (range: 9-82 years). According to the AJCC-1997 staging system, there were 11 (7.6%), 35 (24.3%), 38 (26.4%), and 60 (41.7%) patients in Stage I, II, III, and IV, respectively. There were 57 (39.6%) patients with T1, 41 (28.5%) with T2, 20 (13.9%) with T3, and 26 (18.1%) with T4 tumors. Histopathologic diagnosis was WHO 2-3 in 137 (95.2%) patients. ERT doses ranged between 58.8 and 74 Gy (median: 66 Gy). There were significantly more patients with young age, N2 status, and Stage III disease in Group B and with Stage II disease in Group A. Significantly more patients received chemotherapy in Group B. BRT with an HDR 192 Ir microSelectron afterloading unit was delivered in 106 patients at the conclusion of ERT using a single-channel nasal applicator. Dose was prescribed at 1 cm from the source, and total dose of 12 Gy in 3 fractions on 3 consecutive days was given immediately after ERT. Besides radiotherapy, 82 (56.9%) patients received cisplatin-based chemotherapy, as well. Follow-up time ranged between 12 and 80 months (median: 32 months). Results: The two groups were comparable in terms of local recurrence, locoregional failure, regional failure, and rate of distant metastasis. Local failure was observed in 11 (10.3%) out of 106

  15. [Prostate cancer boost using high-dose-rate brachytherapy: impact of the learning curve on the dosimetry].

    Science.gov (United States)

    Benhaïm, C; Chand, M-È; Gal, J; Hijazi, H; Gautier, M; Hannoun-Lévi, J-M

    2014-11-01

    To analyse the influence of the learning curve on dosimetric data for high-dose-rate brachytherapy prostate cancer boost. From February 2009 to May 2012, after a first course of external beam radiation therapy (46Gy/23 fractions), 124 patients underwent high-dose-rate brachytherapy boost using Plato™ (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden). The impact of the learning curve on the dosimetric quality of the prostate implant was assessed. The dosimetric data have been analysed: clinical target volume (CTV), D90 (dose to 90 % of CTV), D100, V100 (part on the CTV receiving 100 % of the dose), V150, V200 and DHI (dose non-homogeneity index). The doses delivered to 0.1, 1 and 2 cm(3) of the rectum and urethra were calculated. During the study period (39 months), a significant reduction of V150 (Plearning curve period. Copyright © 2014 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  16. The feasibility study and characterization of a two-dimensional diode array in “magic phantom” for high dose rate brachytherapy quality assurance

    International Nuclear Information System (INIS)

    Espinoza, A.; Beeksma, B.; Petasecca, M.; Fuduli, I.; Porumb, C.; Cutajar, D.; Lerch, M. L. F.; Rosenfeld, A. B.; Corde, S.; Jackson, M.

    2013-01-01

    Purpose: High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly 192 Ir with an air KERMA strength range between 20 000 and 40 000 U, where 1 U = 1 μGy m 2 /h in air) through applicators directly into the patient's prescribed region of treatment. Due to the obvious ramifications of incorrect treatment while using such an active source, it is essential that there are methods for quality assurance (QA) that can directly and accurately verify the treatment plan and the functionality of the remote afterloader. This paper describes the feasibility study of a QA system for HDR brachytherapy using a phantom based two-dimensional 11 × 11 epitaxial diode array, named “magic phantom.”Methods: The HDR brachytherapy treatment plan is translated to the phantom with two rows of 10 (20 in total) HDR source flexible catheters, arranged above and below the diode array “magic plate” (MP). Four-dimensional source tracking in each catheter is based upon a developed fast iterative algorithm, utilizing the response of the diodes in close proximity to the 192 Ir source, sampled at 100 ms intervals by a fast data acquisition (DAQ) system. Using a 192 Ir source in a solid water phantom, the angular response of the developed epitaxial diodes utilized in the MP and also the variation of the MP response as a function of the source-to-detector distance (SDD) were investigated. These response data are then used by an iterative algorithm for source dwelling position determination. A measurement of the average transit speed between dwell positions was performed using the diodes and a fast DAQ.Results: The angular response of the epitaxial diode showed a variation of 15% within 360°, with two flat regions above and below the detector face with less than 5% variation. For SDD distances of between 5 and 30 mm the relative response of

  17. Interstitial high-dose-rate brachytherapy boost: The feasibility and cosmetic outcome of a fractionated outpatient delivery scheme

    International Nuclear Information System (INIS)

    Manning, Matthew A.; Arthur, Douglas W.; Schmidt-Ullrich, Rupert K.; Arnfield, Mark R.; Amir, Cyrus; Zwicker, Robert D.

    2000-01-01

    Purpose: To evaluate the feasibility, potential toxicity, and cosmetic outcome of fractionated interstitial high dose rate (HDR) brachytherapy boost for the management of patients with breast cancer at increased risk for local recurrence. Methods and Materials: From 1994 to 1996, 18 women with early stage breast cancer underwent conventionally fractionated whole breast radiotherapy (50-50.4 Gy) followed by interstitial HDR brachytherapy boost. All were considered to be at high risk for local failure. Seventeen had pathologically confirmed final surgical margins of less than 2 mm or focally positive. Brachytherapy catheter placement and treatment delivery were conducted on an outpatient basis. Preplanning was used to determine optimal catheter positions to enhance dose homogeneity of dose delivery. The total HDR boost dose was 15 Gy delivered in 6 fractions of 2.5 Gy over 3 days. Local control, survival, late toxicities (LENT-SOMA), and cosmetic outcome were recorded in follow-up. In addition, factors potentially influencing cosmesis were analyzed by logistic regression analysis. Results: The minimum follow-up is 40 months with a median 50 months. Sixteen patients were alive without disease at last follow-up. There have been no in-breast failures observed. One patient died with brain metastases, and another died of unrelated causes without evidence of disease. Grade 1-2 late toxicities included 39% with hyperpigmentation, 56% with detectable fibrosis, 28% with occasional discomfort, and 11% with visible telangiectasias. Grade 3 toxicity was reported in one patient as persistent discomfort. Sixty-seven percent of patients were considered to have experienced good/excellent cosmetic outcomes. Factors with a direct relationship to adverse cosmetic outcome were extent of surgical defect (p = 0.00001), primary excision volume (p = 0.017), and total excision volume (p = 0.015). Conclusions: For high risk patients who may benefit from increased doses, interstitial HDR

  18. Time-driven activity-based costing of low-dose-rate and high-dose-rate brachytherapy for low-risk prostate cancer.

    Science.gov (United States)

    Ilg, Annette M; Laviana, Aaron A; Kamrava, Mitchell; Veruttipong, Darlene; Steinberg, Michael; Park, Sang-June; Burke, Michael A; Niedzwiecki, Douglas; Kupelian, Patrick A; Saigal, Christopher

    Cost estimates through traditional hospital accounting systems are often arbitrary and ambiguous. We used time-driven activity-based costing (TDABC) to determine the true cost of low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy for prostate cancer and demonstrate opportunities for cost containment at an academic referral center. We implemented TDABC for patients treated with I-125, preplanned LDR and computed tomography based HDR brachytherapy with two implants from initial consultation through 12-month followup. We constructed detailed process maps for provision of both HDR and LDR. Personnel, space, equipment, and material costs of each step were identified and used to derive capacity cost rates, defined as price per minute. Each capacity cost rate was then multiplied by the relevant process time and products were summed to determine total cost of care. The calculated cost to deliver HDR was greater than LDR by $2,668.86 ($9,538 vs. $6,869). The first and second HDR treatment day cost $3,999.67 and $3,955.67, whereas LDR was delivered on one treatment day and cost $3,887.55. The greatest overall cost driver for both LDR and HDR was personnel at 65.6% ($4,506.82) and 67.0% ($6,387.27) of the total cost. After personnel costs, disposable materials contributed the second most for LDR ($1,920.66, 28.0%) and for HDR ($2,295.94, 24.0%). With TDABC, the true costs to deliver LDR and HDR from the health system perspective were derived. Analysis by physicians and hospital administrators regarding the cost of care afforded redesign opportunities including delivering HDR as one implant. Our work underscores the need to assess clinical outcomes to understand the true difference in value between these modalities. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  19. Outcomes of salvage high-dose-rate brachytherapy with or without external beam radiotherapy for isolated vaginal recurrence of endometrial cancer

    Directory of Open Access Journals (Sweden)

    Shuhei Sekii

    2017-05-01

    Full Text Available Purpose: This study was designed to retrospectively analyze outcomes of high-dose-rate (HDR brachytherapy, with or without external beam radiotherapy (EBRT, in patients with vaginal recurrence of endometrial carcinoma, and to identify factors prognostic of patient outcomes. Material and methods : The medical records of all patients who underwent HDR brachytherapy for initial recurrence in the vagina of endometrial cancer after definitive surgery between 1992 and 2014 were retrospectively reviewed. All patients underwent either intracavitary brachytherapy (ICBT or interstitial brachytherapy (ISBT with or without EBRT. Late toxicity was graded using the EORTC (LENT/SOMA scale, revised in 1995. Results : Thirty-seven patients were identified. The median follow-up time was 48 months (range: 6-225 months. Of these 37 patients, 23 underwent ICBT, 14 underwent ISBT, and 26 underwent EBRT. Tumor size at first examination of initial relapse was significantly larger in the ISBT than in the ICBT group. The 4-year respective overall survival (OS, local control (LC, and progression-free survival (PFS rates in the entire cohort were 81.0%, 77.9%, and 56.8%, respectively. The interval between diagnosis of first recurrence and radiotherapy (< 3 months, ≥ 3 months was a significant predictor of LC and PFS. OS and LC rates did not differ significantly in the ICBT and ISBT groups. Two patients experienced grade 2 rectal bleeding, and four experienced grade 2 hematuria. No grade 3 or higher late complications were observed. Conclusions : Salvage HDR brachytherapy is an optimal for treating vaginal recurrence of endometrial carcinoma with acceptable morbidity. Early radiotherapy, including brachytherapy, should be considered for women who experience vaginal recurrence of endometrial cancer.

  20. Utility rate comparisons and management efficiency

    International Nuclear Information System (INIS)

    Tolley, G.S.; Bodmer, E.C.

    1990-01-01

    This article reports on the results of the writers' effort to develop a valid measurement of the comparative efficiency of utility company managements - one free of the obvious imperfections of using simple retail rate levels for that purpose (which are discussed). The key to their method is the disaggregation of those elements of total cost which are beyond management's control from those cost elements that may correctly be attributed to management quality

  1. Radioactive waste evacuation of the sources of a low dose rate brachytherapy unit

    International Nuclear Information System (INIS)

    Serrada, A.; Huerga, C.; Santa Olalla, I.; Vicedo, A.; Corredoira, E.; Plaza, R.; Vidal, J.; Tellez, M.

    2006-01-01

    Introduction The second class Radioactive Installation start -up authorization makes responsible for its security to the installation exploiter and supervisor. The specifications established in the authorization, which are mandatory, point out several actions, some of these actions are the hermeticity tests of radioactive sources an radiologic controls of environment dosimetry. It is necessary to optimize the time spent in each activity, managing them as reasonably as possible. An important matter to take into account is to keep and control only those radioactive or radiological equipment which, even if are in work, have an appropriate performance for the patient treatment Material And Method a Paz hospital has an intracavity brachytherapy (L.D.R.), Curietron model. The Radioprotection Department proposed to remove from service the unit due to its age, this was carried out by the Commission of Guarantee and Quality Control. There were different solutions taken into account to decommission the unit, finally the option chosen as the most convenient for the installation was to manage directly the withdrawal of the radioactive material which consisted of seven Cs-137 probes model CsM1 and total nominal certificated activity of 7770 MBq ( 210 mCi ) dated in May 2005. It also has to be considered as a radioactive waste the inner storage elements of the Curietron and the transport and storage curie stock, built with depleted uranium. To accomplish this aim an evacuation container was designed consisting of an alloy of low-melting point (M.C.P.96), which fulfills the transport conditions imposed by E.N.R.E.S.A. ( Empresa Nacional de Residuos Radiactivos, S.A). A theoretical calculation was performed to estimate the thickness of the shield which adequate to the rate of dose in contact demanded. Accuracy of these calculations has been verified using T.L. dosimetry. Results The radiation levels during the extraction intervention of the radioactive probes and its transfer to

  2. Radioactive waste evacuation of the sources of a low dose rate brachytherapy unit

    Energy Technology Data Exchange (ETDEWEB)

    Serrada, A.; Huerga, C.; Santa Olalla, I.; Vicedo, A.; Corredoira, E.; Plaza, R.; Vidal, J.; Tellez, M. [La Paz Hospital, Madrid (Spain)

    2006-07-01

    Introduction The second class Radioactive Installation start -up authorization makes responsible for its security to the installation exploiter and supervisor. The specifications established in the authorization, which are mandatory, point out several actions, some of these actions are the hermeticity tests of radioactive sources an radiologic controls of environment dosimetry. It is necessary to optimize the time spent in each activity, managing them as reasonably as possible. An important matter to take into account is to keep and control only those radioactive or radiological equipment which, even if are in work, have an appropriate performance for the patient treatment Material And Method a Paz hospital has an intracavity brachytherapy (L.D.R.), Curietron model. The Radioprotection Department proposed to remove from service the unit due to its age, this was carried out by the Commission of Guarantee and Quality Control. There were different solutions taken into account to decommission the unit, finally the option chosen as the most convenient for the installation was to manage directly the withdrawal of the radioactive material which consisted of seven Cs-137 probes model CsM1 and total nominal certificated activity of 7770 MBq ( 210 mCi ) dated in May 2005. It also has to be considered as a radioactive waste the inner storage elements of the Curietron and the transport and storage curie stock, built with depleted uranium. To accomplish this aim an evacuation container was designed consisting of an alloy of low-melting point (M.C.P.96), which fulfills the transport conditions imposed by E.N.R.E.S.A. ( Empresa Nacional de Residuos Radiactivos, S.A). A theoretical calculation was performed to estimate the thickness of the shield which adequate to the rate of dose in contact demanded. Accuracy of these calculations has been verified using T.L. dosimetry. Results The radiation levels during the extraction intervention of the radioactive probes and its transfer to

  3. Implementation of three-dimensional planning in brachytherapy of high dose rate for gynecology therapies

    International Nuclear Information System (INIS)

    Sales, Camila Pessoa de

    2015-01-01

    This work aims to implement the three-dimensional (3D) planning for gynecological brachytherapy treatments. For this purpose, tests of acceptance and commissioning of brachytherapy equipment were performed to establish a quality and periodic assurance program. For this purpose, an important step was searching for a material to be used as a dummy source, since the applicators do not have any specific dummy. In addition, the validation of the use of applicators library was made for reconstruction in computed tomography (CT) and magnetic resonance imaging (MRI). In order to validate 3D planning, comparison of doses in dose assessment points used in bidimensional (2D) plans have been performed with volumetric doses to adjacent organs to the tumor. Finally, a protocol was established for 3D brachytherapy planning alternately using magnetic resonance image (MRI) and CT images, making evaluation of the dose in the tumor through the recording of MR and CT images. It was not possible to find a suitable material that could be used as dummy in MRI. However, the acquisition of the license's library for the applicators made possible the 3D planning based on MRI. No correlation was found between volumetric and specific doses analyzed, showing the importance of the implementation of 3D planning. The average ratio between D 2cc and ICRU Bladder dose was 1,74, 22% higher than the ratio found by others authors. For the rectum, D 2cc was less than dose point for 60% of fractions; the average difference was 12,5%. The average ratio between D 2cc and point dose rectum, 0,85, is equivalent to the value showed by Kim et al, 0,91. The D 2cc for sigmoid was 69% higher than point dose used, unless it was not possible compare this value, since the sigmoid point used in the 2D procedures is not used in others institutes. Relative dose in 2 cc of sigmoid was 57% of the prescription dose, the same value was found by in literature. This work enabled the implementation of a viable

  4. Palladium-103 brachytherapy for prostate carcinoma

    International Nuclear Information System (INIS)

    Blasko, John C.; Grimm, Peter D.; Sylvester, John E.; Badiozamani, Kas Ray; Hoak, David; Cavanagh, William

    2000-01-01

    Purpose: A report of biochemical outcomes for patients treated with palladium-103 (Pd-103) brachytherapy over a fixed time interval. Methods and Materials: Two hundred thirty patients with clinical stage T1-T2 prostate cancer were treated with Pd-103 brachytherapy and followed with prostate-specific antigen (PSA) determinations. Kaplan-Meier estimates of biochemical failure on the basis of two consecutive elevations of PSA were utilized. Multivariate risk groups were constructed. Aggregate PSA response by time interval was assessed. Results: The overall biochemical control rate achieved at 9 years was 83.5%. Failures were local 3.0%; distant 6.1%; PSA progression only 4.3%. Significant risk factors contributing to failure were serum PSA greater than 10 ng/ml and Gleason sum of 7 or greater. Five-year biochemical control for those exhibiting neither risk factor was 94%; one risk factor, 82%; both risk factors, 65%. When all 1354 PSA determinations obtained for this cohort were considered, the patients with a proportion of PSAs ≤ 0.5 ng/ml continued to increase until at least 48 months post-therapy. These data conformed to a median PSA half-life of 96.2 days. Conclusions: Prostate brachytherapy with Pd-103 achieves a high rate of biochemical and clinical control in patients with clinically organ-confined disease. PSA response following brachytherapy with low-dose-rate isotopes is protracted

  5. Rating criteria and the Canadian utility sector

    International Nuclear Information System (INIS)

    DiPerna, D.

    2003-01-01

    This Power Point presentation provides a brief overview of Standard and Poor's, their rating process, rating methodology, symbols, and rating trends. Key industry issues are described as being deregulation within the electric power and petroleum industry, and a series of risks including regulatory, sovereign, political, event, and financial risks. The paper summarized by noting that transmission and distribution companies have the greatest potential for high credit quality, based on monopoly status, efficient operations and supportive regulation. However, they will be challenged by regulatory and integration issues. The greatest business risk will be faced by generation companies. It was also noted that outside of Alberta and Nova Scotia, provincially-owned utilities dominate the electric power industry. 6 tabs., 13 figs

  6. High-dose-rate brachytherapy in the treatment of uterine cervix cancer. Analysis of dose effectiveness and late complications

    International Nuclear Information System (INIS)

    Ferrigno, Robson; Novaes, Paulo Eduardo Ribeiro dos Santos; Pellizzon, Antonio Cassio Assis; Maia, Maria Aparecida Conte; Fogarolli, Ricardo Cesar; Gentil, Andre Cavalcanti; Salvajoli, Joao Victor

    2001-01-01

    Purpose: This retrospective analysis aims to report results of patients with cervix cancer treated by external beam radiotherapy (EBR) and high-dose-rate (HDR) brachytherapy. Methods and Materials: From September 1992 to December 1996, 138 patients with FIGO Stages II and III and mean age of 56 years were treated. Median EBR to the whole pelvis was 45 Gy in 25 fractions. Parametrial boost was performed in 93% of patients, with a median dose of 14.4 Gy. Brachytherapy with HDR was performed during EBR or following its completion with a dose of 24 Gy in four weekly fractions of 6 Gy to point A. Median overall treatment time was of 60 days. Patient age, tumor stage, and overall treatment time were variables analyzed for survival and local control. Cumulative biologic effective dose (BED) at rectal and bladder reference points were correlated with late complications in these organs and dose of EBR at parametrium was correlated with small bowel complications. Results: Median follow-up time was 38 months. Overall survival, disease-free survival, and local control at 5 years was 53.7%, 52.7%, and 62%, respectively. By multivariate and univariate analysis, overall treatment time up to 50 days was the only statistically significant adverse variable for overall survival (p=0.003) and actuarial local control (p=0.008). The 5-year actuarial incidence of rectal, bladder, and small bowel late complications was 16%, 11%, and 14%, respectively. Patients treated with cumulative BED at rectum points above 110 Gy 3 and at bladder point above 125 Gy 3 had a higher but not statistically significant 5-year actuarial rate of complications at these organs (18% vs. 12%, p=0.49 and 17% vs. 9%, p=0.20, respectively). Patients who received parametrial doses larger than 59 Gy had a higher 5-year actuarial rate of complications in the small bowel; however, this was not statistically significant (19% vs. 10%, p=0.260). Conclusion: This series suggests that 45 Gy to the whole pelvis combined with

  7. An analysis of acute complications and perioperative morbidity from high dose rate brachytherapy in the treatment of gynecological malignancies

    International Nuclear Information System (INIS)

    Sarkaria, Jann N.; Petereit, Daniel G.; Kinsella, Timothy J.; Buchler, Dolores A.

    1995-01-01

    Purpose: To evaluate the acute morbidity and mortality for high dose-rate (HDR) brachytherapy performed in an outpatient setting in the treatment of gynecological malignancies, and to identify possible risk factors for adverse outcomes. Materials and Methods: One hundred seventy-one patients with cervical (n=129) or uterine (n=42) carcinoma with an intact uterus were evaluated and treated from August 1989 through December 1994, with at least part of their therapy delivered with intracavitary HDR 192 Ir radiation. A total of 830 ICR insertions were performed with greater than 95% done on an outpatient basis under heavy intravenous sedation using fentanyl and midazolam. Perioperative morbidity and mortality were recorded for any event occurring within 30 days of the completion of therapy. Anesthesia risk was evaluated retrospectively in all patients based on the American Society of Anesthesiologists' (ASA) Physical Class System. Results: The uterine patients, many treated with radiation alone because of morbid obesity or medical inoperability, had a significantly higher perioperative morbidity and mortality rate as compared to the cervix patient cohort. Thirteen of the 42 (31%) uterine patients and 8 of the 129 (6%) cervix patients required hospitalization within 30 days of treatment completion (p 2) experienced greater morbidity and mortality, while the best predictor of complications in the cervix patients was age greater than 70 years. For the entire cohort of patients, no correlation was found between the 30 day morbidity and mortality and the doses of fentanyl and midazolam used or the length of the procedure. Conclusions: The acute complication rate from HDR brachytherapy performed on an outpatient basis with heavy intravenous sedation is acceptable for the great majority of patients who present for treatment. However, the high morbidity and mortality experienced by certain patient cohorts suggests that careful assessment of the risk/benefit ratio for treatment

  8. The prediction of late rectal complications in patients treated with high dose-rate brachytherapy for carcinoma of the cervix

    International Nuclear Information System (INIS)

    Clark, Brenda G.; Souhami, Luis; Roman, Ted N.; Chappell, Rick; Evans, Michael D.C.; Fowler, Jack F.

    1997-01-01

    Purpose: The aim of this work is to investigate an unusually high rate of late rectal complications in a group of 43 patients treated with concomitant irradiation and chemotherapy for carcinoma of the cervix between December 1988 and April 1991, with a view to identifying predictive factors. Methods and Materials: The biologically effective dose received by each patient to the rectal reference point defined by the International Commission of Radiation Units and Measurements, Report 38, were calculated. Radiotherapy consisted of 46 Gy external beam irradiation plus three high dose-rate intracavitary treatments of 10 Gy each prescribed to point A. Cisplatin 30 mg/m 2 was given weekly throughout the duration of the irradiation. The results have been compared to data from 119 patients treated with irradiation alone to assess the confounding effect of the cisplatin. Results: The relationship between the biologically effective dose delivered to the rectal reference point and the development of late complications shows a strong dose-response with a threshold for complications occurring at approximately 125 Gy 3 corresponding to a brachytherapy dose of approximately 8 Gy per fraction. This value is approximately the same biologically effective dose threshold as that found for external beam irradiation in the head and neck region. The data from the group of patients treated without cisplatin is comparable to the data from the first group of patients in the lower dose ranges; the higher doses were not used and thus are not available for comparison. Conclusion: Using the linear quadratic model applied to our clinical results, we have established a threshold for late rectal complications for patients treated with external beam irradiation and high dose-rate brachytherapy for carcinoma of the cervix. This threshold is consistent with similar data for external beam irradiation in the head and neck region

  9. Robustness to source displacement in dual air kerma strength planning for focal low-dose-rate brachytherapy of prostate cancer.

    Science.gov (United States)

    Mahdavi, S Sara; Spadinger, Ingrid T; Chng, Nicholas T; Morris, W James

    2016-01-01

    To describe the use of dual source strength implants for focal low-dose-rate brachytherapy. An interneedle dual source strength planning strategy is described for focal low-dose-rate brachytherapy of the prostate. The implanted treatment plans were designed using peripheral (except near the rectum) needles loaded with high strength (0.9 U) sources and central needles loaded with low strength (0.4 U) sources ("interneedle" dual strength planning). This approach has been applied for focally treating 3 patients. In this article, we compare the characteristics and robustness to source motion of interneedle dual strength planning with four alternative planning strategies (single strength high, low, and intermediate, and intraneedle dual strength) on 50 simulated cases. Interneedle dual source strength planning results in greater robustness to source motion and overall lower seed and needle density compared to the standard low source strength planning currently used in our centre. This planning approach is also significantly superior to single strength high, single strength intermediate and intraneedle dual strength planning strategies in terms of high dose to the urethral avoidance structure. The use of interneedle dual source strength treatment plans for focal low-dose-rate brachytherapy is possibly the practical solution for limiting the density of sources required to deliver the prescribed dose while limiting proximity of high strength sources to organs at risk. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  10. Permanent interstitial low-dose-rate brachytherapy for patients with low risk prostate cancer. An interim analysis of 312 cases

    Energy Technology Data Exchange (ETDEWEB)

    Badakhshi, Harun; Graf, Reinhold; Budach, Volker; Wust, Peter [University Hospital Berlin, Department for Radiation Oncology of Charite School of Medicine, Berlin (Germany)

    2015-04-01

    The biochemical relapse-free survival (bRFS) rate after treatment with permanent iodine-125 seed implantation (PSI) or combined seeds and external beam radiotherapy (COMB) for clinical stage T1-T2 localized prostate cancer is a clinically relevant endpoint. The goal of this work was to evaluate the influence of relevant patient- and treatment-related factors. The study population comprised 312 consecutive patients treated with permanent seed implantation. All patients were evaluable for analysis of overall survival (OS) and disease-specific survival (DSS), 230 for bRFS, of which 192 were in the PSI group and 38 in the COMB group. The prescribed minimum peripheral dose was 145 Gy for PSI, for COMB 110 Gy implant and external beam radiotherapy of 45 Gy. The median follow-up time was 33 months (range 8-66 months). bRFS was defined as a serum prostate-specific antigen (PSA) level ≤ 0.2 ng/ml at last follow-up. Overall, the actuarial bRFS at 50 months was 88.4 %. The 50-month bRFS rate for PSI and COMB was 90.9 %, and 77.2 %, respectively. In the univariate analysis, age in the categories ≤ 63 and > 63 years (p < 0.00), PSA nadir (≤ 0.5 ng/ml and > 0.5 ng/ml) and PSA bounce (yes/no) were the significant predicting factors for bRFS. None of the other patient and treatment variables (treatment modality, stage, PSA, Gleason score, risk group, number of risk factors, D90 and various other dose parameters) were found to be a statistically significant predictor of 50-month bRFS. The biochemical failure rates were low in this study. As a proof of principle, our large monocenteric analysis shows that low-dose-rate brachytherapy is an effective and safe procedure for patients with early stage prostate cancer. (orig.) [German] Das biochemisch rezidivfreie Ueberleben (bRFS) nach der Brachytherapie mit permanenter Iod-125-Seed-Implantation (PSI) oder in Kombination mit externer Radiotherapie (COMB) ist beim Patienten mit fruehem Prostatakarzinom (T1/T2) ein relevanter

  11. Needle migration and dosimetric impact in high-dose-rate brachytherapy for prostate cancer evaluated by repeated MRI.

    Science.gov (United States)

    Buus, Simon; Lizondo, Maria; Hokland, Steffen; Rylander, Susanne; Pedersen, Erik M; Tanderup, Kari; Bentzen, Lise

    To quantify needle migration and dosimetric impact in high-dose-rate brachytherapy for prostate cancer and propose a threshold for needle migration. Twenty-four high-risk prostate cancer patients treated with an HDR boost of 2 × 8.5 Gy were included. Patients received an MRI for planning (MRI1), before (MRI2), and after treatment (MRI3). Time from needle insertion to MRI3 was ∼3 hours. Needle migration was evaluated from coregistered images: MRI1-MRI2 and MRI1-MRI3. Dose volume histogram parameters from the treatment plan based on MRI1 were related to parameters based on needle positions in MRI2 or MRI3. Regression was used to model the average needle migration per implant and change in D90 clinical target volume, CTV prostate+3mm . The model fit was used for estimating the dosimetric impact in equivalent dose in 2 Gy fractions for dose levels of 6, 8.5, 10, 15, and 19 Gy. Needle migration was on average 2.2 ± 1.8 mm SD from MRI1-MRI2 and 5.0 ± 3.0 mm SD from MRI1-MRI3. D90 CTV prostate+3mm was robust toward average needle migration ≤3 mm, whereas for migration >3 mm D90 decreased by 4.5% per mm. A 3 mm of needle migration resulted in a decrease of 0.9, 1.7, 2.3, 4.8, and 7.6 equivalent dose in 2 Gy fractions for dose levels of 6, 8.5, 10, 15, and 19 Gy, respectively. Substantial needle migration in high-dose-rate brachytherapy occurs frequently in 1-3 hours following needle insertion. A 3-mm threshold of needle migration is proposed, but 2 mm may be considered for dose levels ≥15 Gy. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  12. Validation of MRI to TRUS registration for high-dose-rate prostate brachytherapy.

    Science.gov (United States)

    Poulin, Eric; Boudam, Karim; Pinter, Csaba; Kadoury, Samuel; Lasso, Andras; Fichtinger, Gabor; Ménard, Cynthia

    The objective of this study was to develop and validate an open-source module for MRI to transrectal ultrasound (TRUS) registration to support tumor-targeted prostate brachytherapy. In this study, 15 patients with prostate cancer lesions visible on multiparametric MRI were selected for the validation. T2-weighted images with 1-mm isotropic voxel size and diffusion weighted images were acquired on a 1.5T Siemens imager. Three-dimensional (3D) TRUS images with 0.5-mm slice thickness were acquired. The investigated registration module was incorporated in the open-source 3D Slicer platform, which can compute rigid and deformable transformations. An extension of 3D Slicer, SlicerRT, allows import of and export to DICOM-RT formats. For validation, similarity indices, prostate volumes, and centroid positions were determined in addition to registration errors for common 3D points identified by an experienced radiation oncologist. The average time to compute the registration was 35 ± 3 s. For the rigid and deformable registration, respectively, Dice similarity coefficients were 0.87 ± 0.05 and 0.93 ± 0.01 while the 95% Hausdorff distances were 4.2 ± 1.0 and 2.2 ± 0.3 mm. MRI volumes obtained after the rigid and deformable registration were not statistically different (p > 0.05) from reference TRUS volumes. For the rigid and deformable registration, respectively, 3D distance errors between reference and registered centroid positions were 2.1 ± 1.0 and 0.4 ± 0.1 mm while registration errors between common points were 3.5 ± 3.2 and 2.3 ± 1.1 mm. Deformable registration was found significantly better (p < 0.05) than rigid registration for all parameters. An open-source MRI to TRUS registration platform was validated for integration in the brachytherapy workflow. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  13. External beam radiotherapy boosted with high dose rate brachytherapy in completely resected uterine sarcomas. Is this a treatment option?

    International Nuclear Information System (INIS)

    Pellizzon, Antonio Cassio Assis; Novaes, Paulo Eduardo Ribeiro dos Santos; Maia, Maria Aparecida Conte; Ferrigno, Robson; Fogarolli, Ricardo; Salvajoli, Joao Vitor

    2005-01-01

    Uterine sarcoma (US) is a relative rare tumor, which accounts for only about 3-5% of all uterine cancers. Aggressive cytoreductive surgery at the time of the initial diagnosis with maximum tumor debulking may lead to a prolonged survival or cure. Objective: to identify and review the role of adjuvant external beam radiation therapy (EBRT) associated with high dose rate brachytherapy (HDRB) in the management of patients presenting US with complete resection. Material and methods: this study is a retrospective analysis of 23 patients with US treated from 10/92 to 03/03, with surgery, external beam radiation therapy (EBRT) and high dose rate brachytherapy (HDRB). The inclusion criteria for study participation included: histologically proven and graded US, completely resection of tumor, Karnofsky status 60-100, absence of significant infection, and recovery from recent surgery. Results: The median age of patients was 62 years (range 39-84); ten-year actuarial disease-free and overall survivals were 42.2% and 63.4%, respectively. On univariate analysis, predictive factors for disease-free survival (DFS) were age at initial presentation (p=0.0268), parity (p=0.0441), tumor grade (p= 0.0095), cervical or vaginal invasion (p=0.0014) and node dissection at time of surgery (p= 0.0471). On multivariate analysis, the only predictive factor was cervical or vaginal invasion (p= 0.048), hazard ratio of 4.7. Conclusion: it is quite likely that neither radiotherapy nor chemotherapy alone will appreciably improve survival in US. If radiation therapy provides better locoregional tumor control, hematogenous metastases will assume an even greater proportion of treatment failures. Unfortunately, our small and heterogeneous group analyzed precludes any definitive conclusions about the impact of HDRB associated to EBRT radiation therapy on recurrence or survival. (author)

  14. Verification of radiation dose to a and b position at cervix during low dose rate 137Cs brachytherapy in bangladesh

    International Nuclear Information System (INIS)

    Roy, S.; Begur, M.

    2001-01-01

    A manual low dose rate 137Cs brachytherapy consists two sets viz. 440 mCi (tandem 120,40,40, 40, 40 and ovoids 40, 40 mCi each) and 360 mCi ( tandem 120, 40, 40 mCi and ovoids 40, 40 Mci each) having the dose rates at A were 155.2 cGy/hr and 140.8 cGy/hr. respectively on June 1996) was supplied by the Bhabha Atomic Research Centre (BARC), Mumbai, India and are being used in the Delta Medical Centre Limited, Mirpur, Dhaka, Bangladesh for gynecological insertion. BARC also supplied the operation manual quoting the dose at point A and B of cervix of the patient only for straight uterine tubes and separation between vaginal ovoids of 2, 3 and 4 cm. BARC also mentioned that the dose at A and B are within 1-2 % of the mean dose. Manual calculation was done to compare the dose at point A and B for ten intracavitary insertions in the hospital to compare those with the value supplied by the BARC. It was found that the dose varied at point A from +0.46% to +9.11% for eight patients and -3.4% and -5.96% for two patients with the quoted value. Dose at B varied from +0.59% to 9.8% for nine patients and -10.94% for one patient with the quoted value supplied by the supplier. This is not unusual because the tandem used for treatment were with different angles such as, 15 degree, 30 degree etc. as per anatomy of the patient. Moreover, the tolerance dose of the fornix region is much more higher (about 140 Gy) than that of the other critical organs. Overall prognosis of the patients, treated so far, using this manual brachytherapy and performing manual calculation were found to satisfactory. So, the result shows a good result with the manual treatment planning

  15. Independent assessment of source position for gynecological applicator in high-dose-rate brachytherapy.

    Science.gov (United States)

    Okamoto, Hiroyuki; Nakamura, Satoshi; Nishioka, Shie; Iijima, Kotaro; Wakita, Akihisa; Abe, Yukinao; Tohyama, Naoki; Kawamura, Shinji; Minemura, Toshiyuki; Itami, Jun

    2017-10-01

    The aim of this study is to describe a phantom designed for independent examination of a source position in brachytherapy that is suitable for inclusion in an external auditing program. We developed a phantom that has a special design and a simple mechanism, capable of firmly fixing a radiochromic film and tandem-ovoid applicators to assess discrepancies in source positions between the measurements and treatment planning system (TPS). Three tests were conducted: 1) reproducibility of the source positions ( n = 5); 2) source movements inside the applicator tube; 3) changing source position by changing curvature of the transfer tubes. In addition, as a trial study, the phantom was mailed to 12 institutions, and 23 trial data sets were examined. The source displacement ΔX and ΔY (reference = TPS) were expressed according to the coordinates, in which the positive direction on the X-axis corresponds to the external side of the applicator perpendicular to source transfer direction Y-axis. Test 1: The 1σ fell within 1 mm irrespective of the dwell positions. Test 2: ΔX were greater around the tip of the applicator owing to the source cable. Test 3: All of the source position changes fell within 1 mm. For postal audit, the mean and 1.96σ in ΔX were 0.8 and 0.8 mm, respectively. Almost all data were located within a positive region along the X-axis due to the source cable. The mean and 1.96σ in ΔY were 0.3 and 1.6 mm, respectively. The variance in ΔY was greater than that in ΔX, and large uncertainties exist in the determination of the first dwell position. The 95% confidence limit was 2.1 mm. In HDR brachytherapy, an effectiveness of independent source position assessment could be demonstrated. The 95% confidence limit was 2.1 mm for a tandem-ovoids applicator.

  16. Dose optimization of intra-operative high dose rate interstitial brachytherapy implants for soft tissue sarcoma

    Directory of Open Access Journals (Sweden)

    Jamema Swamidas

    2009-01-01

    Full Text Available Objective : A three dimensional (3D image-based dosimetric study to quantitatively compare geometric vs. dose-point optimization in combination with graphical optimization for interstitial brachytherapy of soft tissue sarcoma (STS. Materials and Methods : Fifteen consecutive STS patients, treated with intra-operative, interstitial Brachytherapy, were enrolled in this dosimetric study. Treatment plans were generated using dose points situated at the "central plane between the catheters", "between the catheters throughout the implanted volume", at "distances perpendicular to the implant axis" and "on the surface of the target volume" Geometrically optimized plans had dose points defined between the catheters, while dose-point optimized plans had dose points defined at a plane perpendicular to the implant axis and on the target surface. Each plan was graphically optimized and compared using dose volume indices. Results : Target coverage was suboptimal with coverage index (CI = 0.67 when dose points were defined at the central plane while it was superior when the dose points were defined at the target surface (CI=0.93. The coverage of graphically optimized plans (GrO was similar to non-GrO with dose points defined on surface or perpendicular to the implant axis. A similar pattern was noticed with conformity index (0.61 vs. 0.82. GrO were more conformal and less homogeneous compared to non-GrO. Sum index was superior for dose points defined on the surface of the target and relatively inferior for plans with dose points at other locations (1.35 vs. 1.27. Conclusions : Optimization with dose points defined away from the implant plane and on target results in superior target coverage with optimal values of other indices. GrO offer better target coverage for implants with non-uniform geometry and target volume.

  17. Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification techniques.

    Science.gov (United States)

    Palmer, Antony; Bradley, David; Nisbet, Andrew

    2012-06-01

    This study provides a review of recent publications on the physics-aspects of dosimetric accuracy in high dose rate (HDR) brachytherapy. The discussion of accuracy is primarily concerned with uncertainties, but methods to improve dose conformation to the prescribed intended dose distribution are also noted. The main aim of the paper is to review current practical techniques and methods employed for HDR brachytherapy dosimetry. This includes work on the determination of dose rate fields around brachytherapy sources, the capability of treatment planning systems, the performance of treatment units and methods to verify dose delivery. This work highlights the determinants of accuracy in HDR dosimetry and treatment delivery and presents a selection of papers, focusing on articles from the last five years, to reflect active areas of research and development. Apart from Monte Carlo modelling of source dosimetry, there is no clear consensus on the optimum techniques to be used to assure dosimetric accuracy through all the processes involved in HDR brachytherapy treatment. With the exception of the ESTRO mailed dosimetry service, there is little dosimetric audit activity reported in the literature, when compared with external beam radiotherapy verification.

  18. Treatment of skin carcinomas of the face by high-dose-rate brachytherapy and custom-made surface molds

    International Nuclear Information System (INIS)

    Guix, Benjamin; Finestres, Fernando; Tello, Jose-Ignacio; Palma, Cesar; Martinez, Antonio; Guix, Jose-Ramon; Guix, Ricardo

    2000-01-01

    Purpose: To analyze the results obtained in a prospective group of patients with basal or squamous cell skin carcinomas of the face treated by high-dose-rate (HDR) brachytherapy via custom-made surface molds. Methods and Materials: A total of 136 patients with basal or squamous cell carcinomas of the face were treated between March 1992 and March 1997 by surface molds and HDR brachytherapy with iridium-192. Nineteen patients were treated with standard Brock applicators and 117 patients with custom-made polymethyl methacrylate applicators, built over a plaster mold obtained of the patient's face. Minimum dose administered to the tumor was 6000 to 6500 cGy in 33 to 36 fractions at 180 cGy/fraction in lesions of up to 4 cm. Lesions greater than 4 cm were boosted up to 7500-8000 cGy after a 3-week pause. Results: With the custom-made surface molds, the dose distribution was uniform in the surface of the skin and at 5 mm depth in the whole area of the applicator. Differences between the areas of maximum and minimum dose at this depth never reached values higher than 5% of the prescribed dose. At the edges of the custom-made molds dose gradient was sharp, with the detected dose at 5 mm from the applicator being negligible. All the patients were complete responders. There were 3 local recurrences, 1/73 patients treated for primary tumor and 2/63 patients treated for recurrent tumor. Actuarial local control at 5 years for all patients was 98%, for those patients with primary tumors 99%, and for recurrent patients 87%. The treatment tolerance was excellent in all cases. No severe, early, or late, complications were detected. Conclusions: Radiotherapy is a highly effective treatment of skin carcinomas of the face. Custom-made molds, to be used in conjunction with HDR brachytherapy equipment, make possible a uniform dose distribution, with a sharp dose gradient in the limits of applicators. Custom-made surface molds are easy and safe to use, and they fit very accurately for

  19. HDRMC, an accelerated Monte Carlo dose calculator for high dose rate brachytherapy with CT-compatible applicators

    Energy Technology Data Exchange (ETDEWEB)

    Chibani, Omar, E-mail: omar.chibani@fccc.edu; C-M Ma, Charlie [Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States)

    2014-05-15

    Purpose: To present a new accelerated Monte Carlo code for CT-based dose calculations in high dose rate (HDR) brachytherapy. The new code (HDRMC) accounts for both tissue and nontissue heterogeneities (applicator and contrast medium). Methods: HDRMC uses a fast ray-tracing technique and detailed physics algorithms to transport photons through a 3D mesh of voxels representing the patient anatomy with applicator and contrast medium included. A precalculated phase space file for the{sup 192}Ir source is used as source term. HDRM is calibrated to calculated absolute dose for real plans. A postprocessing technique is used to include the exact density and composition of nontissue heterogeneities in the 3D phantom. Dwell positions and angular orientations of the source are reconstructed using data from the treatment planning system (TPS). Structure contours are also imported from the TPS to recalculate dose-volume histograms. Results: HDRMC was first benchmarked against the MCNP5 code for a single source in homogenous water and for a loaded gynecologic applicator in water. The accuracy of the voxel-based applicator model used in HDRMC was also verified by comparing 3D dose distributions and dose-volume parameters obtained using 1-mm{sup 3} versus 2-mm{sup 3} phantom resolutions. HDRMC can calculate the 3D dose distribution for a typical HDR cervix case with 2-mm resolution in 5 min on a single CPU. Examples of heterogeneity effects for two clinical cases (cervix and esophagus) were demonstrated using HDRMC. The neglect of tissue heterogeneity for the esophageal case leads to the overestimate of CTV D90, CTV D100, and spinal cord maximum dose by 3.2%, 3.9%, and 3.6%, respectively. Conclusions: A fast Monte Carlo code for CT-based dose calculations which does not require a prebuilt applicator model is developed for those HDR brachytherapy treatments that use CT-compatible applicators. Tissue and nontissue heterogeneities should be taken into account in modern HDR

  20. A novel adaptive needle insertion sequencing for robotic, single needle MR-guided high-dose-rate prostate brachytherapy

    Science.gov (United States)

    Borot de Battisti, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; Maenhout, M.; Moerland, M. A.

    2017-05-01

    MR-guided high-dose-rate (HDR) brachytherapy has gained increasing interest as a treatment for patients with localized prostate cancer because of the superior value of MRI for tumor and surrounding tissues localization. To enable needle insertion into the prostate with the patient in the MR bore, a single needle MR-compatible robotic system involving needle-by-needle dose delivery has been developed at our institution. Throughout the intervention, dose delivery may be impaired by: (1) sub-optimal needle positioning caused by e.g. needle bending, (2) intra-operative internal organ motion such as prostate rotations or swelling, or intra-procedural rectum or bladder filling. This may result in failure to reach clinical constraints. To assess the first aforementioned challenge, a recent study from our research group demonstrated that the deposited dose may be greatly improved by real-time adaptive planning with feedback on the actual needle positioning. However, the needle insertion sequence is left to the doctor and therefore, this may result in sub-optimal dose delivery. In this manuscript, a new method is proposed to determine and update automatically the needle insertion sequence. This strategy is based on the determination of the most sensitive needle track. The sensitivity of a needle track is defined as its impact on the dose distribution in case of sub-optimal positioning. A stochastic criterion is thus presented to determine each needle track sensitivity based on needle insertion simulations. To assess the proposed sequencing strategy, HDR prostate brachytherapy was simulated on 11 patients with varying number of needle insertions. Sub-optimal needle positioning was simulated at each insertion (modeled by typical random angulation errors). In 91% of the scenarios, the dose distribution improved when the needle was inserted into the most compared to the least sensitive needle track. The computation time for sequencing was less than 6 s per needle track. The

  1. Intraoperative High Dose Rate 32P Brachytherapy for Diffuse Recalcitrant Conjunctival Neoplasms: A Retrospective Case Series and Report of Toxicity

    Science.gov (United States)

    Marr, Brian P.; Abramson, David H.; Cohen, Gil’ad N.; Williamson, Matthew J.; McCormick, Beryl; Barker, Christopher A.

    2017-01-01

    improved in five of the seven eyes. Conclusions and Relevance Our results show the use of Intraoperative High Dose Rate 32P Brachytherapy in selected cases of recalcitrant diffuse conjunctival neoplasms. This technique offers a novel adjunct in the treatment of these cancers. Further follow-up and study is warranted. Trial Registration N/A PMID:25502420

  2. The usefulness of metal markers for CTV-based dose prescription in high-dose-rate interstitial brachytherapy

    International Nuclear Information System (INIS)

    Yoshida, Ken; Mitomo, Masanori; Nose, Takayuki; Koizumi, Masahiko; Nishiyama, Kinji; Yoshida, Mineo

    2002-01-01

    We employ a clinical target volume (CTV)-based dose prescription for high-dose-rate (HDR) interstitial brachytherapy. However, it is not easy to define CTV and organs at risk (OAR) from X-ray film or CT scanning. To solve this problem, we have utilized metal markers since October 1999. Moreover, metal markers can help modify dose prescription. By regulating the doses to the metal markers, refining the dose prescription can easily be achieved. In this research, we investigated the usefulness of the metal markers. Between October 1999 and May 2001, 51 patients were implanted with metal markers at Osaka Medical Center for Cancer and Cardiovascular Diseases (OMCC), Osaka National Hospital (ONH) and Sanda City Hospital (SCH). Forty-nine patients (head and neck: 32; pelvis: 11; soft tissue: 3; breast: 3) using metal markers were analyzed. During operation, we implanted 179 metal markers (49 patients) to CTV and 151 markers (26 patients) to OAR. At treatment planning, CTV was reconstructed judging from the metal markers, applicator position and operation records. Generally, we prescribed the tumoricidal dose to an isodose surface that covers CTV. We also planned to limit the doses to OAR lower than certain levels. The maximum normal tissue doses were decided 80%, 150%, 100%, 50% and 200% of the prescribed doses for the rectum, the urethra, the mandible, the skin and the large vessel, respectively. The doses to the metal markers using CTV-based dose prescription were generated. These were compared with the doses theoretically calculated with the Paris system. Treatment results were also investigated. The doses to the 158 metal markers (42 patients) for CTV were higher than ''tumoricidal dose''. In 7 patients, as a result of compromised dose prescription, 9 markers were lower than the tumoricidal dose. The other 12 markers (7%) were excluded from dose evaluation because they were judged as miss-implanted. The doses to the 142 metal markers (24 patients) for OAR were lower

  3. SU-E-T-546: Use of Implant Volume for Quality Assurance of Low Dose Rate Brachytherapy Treatment Plans

    Energy Technology Data Exchange (ETDEWEB)

    Wilkinson, D; Kolar, M [Radiation Oncology, Cleveland Clinic Foundation, Cleveland, OH (United States)

    2014-06-01

    Purpose: To analyze the application of volume implant (V100) data as a method for a global check of low dose rate (LDR) brachytherapy plans. Methods: Treatment plans for 335 consecutive patients undergoing permanent seed implants for prostate cancer and for 113 patients treated with plaque therapy for ocular melanoma were analyzed. Plaques used were 54 COMS (10 to 20 mm, notched and regular) and 59 Eye Physics EP917s with variable loading. Plots of treatment time x implanted activity per unit dose versus v100 ^.667 were made. V100 values were obtained using dose volume histograms calculated by the treatment planning systems (Variseed 8.02 and Plaque Simulator 5.4). Four different physicists were involved in planning the prostate seed cases; two physicists for the eye plaques. Results: Since the time and dose for the prostate cases did not vary, a plot of implanted activity vs V100 ^.667 was made. A linear fit with no intercept had an r{sup 2} = 0.978; more than 94% of the actual activities fell within 5% of the activities calculated from the linear fit. The greatest deviations were in cases where the implant volumes were large (> 100 cc). Both COMS and EP917 plaque linear fits were good (r{sup 2} = .967 and .957); the largest deviations were seen for large volumes. Conclusions: The method outlined here is effective for checking planning consistency and quality assurance of two types of LDR brachytherapy treatment plans (temporary and permanent). A spreadsheet for the calculations enables a quick check of the plan in situations were time is short (e.g. OR-based prostate planning)

  4. Complete response of endemic Kaposi sarcoma lesions with high-dose-rate brachytherapy: treatment method, results, and toxicity using skin surface applicators.

    Science.gov (United States)

    Kasper, Michael E; Richter, Sam; Warren, Nicholas; Benda, Rashmi; Shang, Charles; Ouhib, Zoubir

    2013-01-01

    To analyze the clinical outcome of Kaposi sarcoma skin lesions treated with high-dose-rate (HDR) brachytherapy in patients with a minimum of 2 years of followup. Between February 2006 and July 2008, all patients with Kaposi sarcoma who received (192)Ir HDR brachytherapy using a skin surface applicator were evaluated for clinical response. Responses to treatment and toxicity were scored using standard criteria. Sixteen cases were collected. Treatment was delivered in four to six fractions, over a period of approximately 12 days. The specified dose ranged from 24 to 35Gy. Median followup the lesion was 41.4 months. No lesion was greater than 2cm. All patients had a complete response to treatment, with no evidence of local recurrence or tumor progression. Thirteen lesions developed Grade 1 and two lesions had Grade 2 acute skin reactions. One patient developed late skin changes with telangiectasias and hypopigmentation. HDR brachytherapy treatment seems to be an effective noninvasive option for patients with small cutaneous Kaposi sarcoma lesions, delivering excellent cosmesis and local control in our small series. Fewer fractions over a shorter period used in our group offer patients more convenience compared with other common regimens. Although HDR is being used more frequently for many surface applications, additional clinical studies with larger numbers of patients and longer followup are needed to confirm the general impression that it is an excellent option for many patients. Copyright © 2013 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  5. Implementation of a High-Dose-Rate Brachytherapy Program for Carcinoma of the Cervix in Senegal: A Pragmatic Model for the Developing World

    International Nuclear Information System (INIS)

    Einck, John P.; Hudson, Alana; Shulman, Adam C.; Yashar, Catheryn M.; Dieng, Mamadou M.; Diagne, Magatte; Gueye, Latifatou; Gningue, Fama; Gaye, Pape M.; Fisher, Brandon J.; Mundt, Arno J.; Brown, Derek W.

    2014-01-01

    West Africa has one of the highest incidence rates of carcinoma of the cervix in the world. The vast majority of women do not have access to screening or disease treatment, leading to presentation at advanced stages and to high mortality rates. Compounding this problem is the lack of radiation treatment facilities in Senegal and many other parts of the African continent. Senegal, a country of 13 million people, had a single 60 Co teletherapy unit before our involvement and no brachytherapy capabilities. Radiating Hope, a nonprofit organization whose mission is to provide radiation therapy equipment to countries in the developing world, provided a high-dose-rate afterloading unit to the cancer center for curative cervical cancer treatment. Here we describe the implementation of high-dose-rate brachytherapy in Senegal requiring a nonstandard fractionation schedule and a novel treatment planning approach as a possible blueprint to providing this technology to other developing countries

  6. Implementation of a High-Dose-Rate Brachytherapy Program for Carcinoma of the Cervix in Senegal: A Pragmatic Model for the Developing World

    Energy Technology Data Exchange (ETDEWEB)

    Einck, John P., E-mail: jeinck@ucsd.edu [Department of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, California (United States); Hudson, Alana [Department of Oncology, Tom Baker Cancer Centre, University of Calgary, Calgary, Alberta (Canada); Shulman, Adam C. [Overlook Medical Center, Summit, New Jersey (United States); Yashar, Catheryn M. [Department of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, California (United States); Dieng, Mamadou M.; Diagne, Magatte; Gueye, Latifatou; Gningue, Fama; Gaye, Pape M. [Départemént de Radiothérapie, Institut Joliot-Curie, Hôpital Aristide Le Dantec, Dakar (Senegal); Fisher, Brandon J. [GammaWest Cancer Services, Salt Lake City, Utah (United States); Mundt, Arno J. [Department of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, California (United States); Brown, Derek W. [Department of Oncology, Tom Baker Cancer Centre, University of Calgary, Calgary, Alberta (Canada)

    2014-07-01

    West Africa has one of the highest incidence rates of carcinoma of the cervix in the world. The vast majority of women do not have access to screening or disease treatment, leading to presentation at advanced stages and to high mortality rates. Compounding this problem is the lack of radiation treatment facilities in Senegal and many other parts of the African continent. Senegal, a country of 13 million people, had a single {sup 60}Co teletherapy unit before our involvement and no brachytherapy capabilities. Radiating Hope, a nonprofit organization whose mission is to provide radiation therapy equipment to countries in the developing world, provided a high-dose-rate afterloading unit to the cancer center for curative cervical cancer treatment. Here we describe the implementation of high-dose-rate brachytherapy in Senegal requiring a nonstandard fractionation schedule and a novel treatment planning approach as a possible blueprint to providing this technology to other developing countries.

  7. Preliminary results of concurrent chemotherapy and radiation therapy using high-dose-rate brachytherapy for cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Ja; Lee, Ji Hye; Lee, Re Na; Suh, Hyun Suk [Ewha Womans University College of Medicine, Seoul (Korea, Republic of)

    2006-09-15

    To determine the efficacy and safety of concurrent chemotherapy and radiation therapy with high-dose-rate brachytherapy for cervical cancer. From January 2001 to December 2002, 30 patients with cervical cancer were treated with concurrent chemotherapy (cisplatin and 5-FU) and definitive radiation therapy. The median age was 58 (range 34 {approx} 74) year old. The pathology of the biopsy sections was squamous cell carcinoma in 29 patients and one was adenocarcinoma. The distribution to FIGO staging system was as follow: stage IB, 7 (23%); IIA, 3 (10%); IIB, 12 (40%); IIIA, 3 (10%); IIIB, 5 (17%). All patients received pelvic external beam irradiation (EBRT) to a total dose of 45 {approx} 50.4 Gy (median: 50.4 Gy) over 5 {approx} 5.5 weeks. Ir-192 HDR intracavity brachytherapy (ICBT) was given after a total dose of 41.1 Gy. HDR-ICBT was performed twice a week, with a fraction point. A dose of 4 Gy and median dose to point A was 28 Gy (range: 16 {approx} 32 Gy) in 7 fractions. The median cumulative biologic effective dose (BED) at point A (EBRT + ICBT) was 88 Gy{sub 10} (range:77 {approx} 94 Gy{sub 10}). The median cumulative BED at ICRU 38 reference point (EBRT + ICBT) was 131 Gy{sub 3} (range: 122 {approx} 140 Gy{sub 3}) at point A, 109 Gy{sub 3} (range:88{approx} 125 Gy{sub 3}) at the rectum and 111 Gy{sub 3} (range: 91 {approx} 123 Gy{sub 3}) at the urinary bladder. Cisplatin (60 mg/m{sup 2}) and 5-FU (1,000 mg/m{sup 2}) was administered intravenously at 2 weeks interval from the first day of radiation for median 5 (range:2 {approx} 6) cycles. The assessment was performed at 1 month after completion of radiation therapy by clinical examination and CT scan. The median follow-up time was 36 months (range:8{approx} 50 months). The complete response rate after concurrent chemo radiation therapy was 93.3%. The 3-yr actuarial pelvic control rate was 87% and 3-yr actuarial overall survival and disease-free survival rate was 93% and 87%, respectively. The local failure

  8. Acute genitourinary toxicity after high-dose-rate (HDR) brachytherapy combined with hypofractionated external-beam radiation therapy for localized prostate cancer: Correlation between the urethral dose in HDR brachytherapy and the severity of acute genitourinary toxicity

    International Nuclear Information System (INIS)

    Akimoto, Tetsuo; Ito, Kazuto; Saitoh, Jun-ichi; Noda, Shin-ei; Harashima, Koichi; Sakurai, Hideyuki; Nakayama, Yuko; Yamamoto, Takumi; Suzuki, Kazuhiro; Nakano, Takashi; Niibe, Hideo

    2005-01-01

    Purpose: Several investigations have revealed that the α/β ratio for prostate cancer is atypically low, and that hypofractionation or high-dose-rate (HDR) brachytherapy regimens using appropriate radiation doses may be expected to yield tumor control and late sequelae rates that are better or at least as favorable as those achieved with conventional radiation therapy. In this setting, we attempted treating localized prostate cancer patients with HDR brachytherapy combined with hypofractionated external beam radiation therapy (EBRT). The purpose of this study was to evaluate the feasibility of using this approach, with special emphasis on the relationship between the severity of acute genitourinary (GU) toxicity and the urethral dose calculated from the dose-volume histogram (DVH) of HDR brachytherapy. Methods and Materials: Between September 2000 and December 2003, 70 patients with localized prostate cancer were treated by iridium-192 HDR brachytherapy combined with hypofractionated EBRT at the Gunma University Hospital. Hypofractionated EBRT was administered in fraction doses of 3 Gy, three times per week; a total dose of 51 Gy was delivered to the prostate gland and the seminal vesicles using the four-field technique. No elective pelvic irradiation was performed. After the completion of EBRT, all the patients additionally received transrectal ultrasonography (TRUS)-guided HDR brachytherapy. The fraction size and the number of fractions in HDR brachytherapy were prospectively changed, whereas the total radiation dose for EBRT was fixed at 51 Gy. The fractionation in HDR brachytherapy was as follows: 5 Gy x 5, 7 Gy x 3, 9 Gy x 2, administered twice per day, although the biologic effective dose (BED) for HDR brachytherapy combined with EBRT, assuming that the α/β ratio is 3, was almost equal to 138 in each fractionation group. The planning target volume was defined as the prostate gland with 5-mm margin all around, and the planning was conducted based on

  9. WE-F-BRD-01: HDR Brachytherapy II: Integrating Imaging with HDR

    International Nuclear Information System (INIS)

    Craciunescu, O; Todor, D; Leeuw, A de

    2014-01-01

    In recent years, with the advent of high/pulsed dose rate afterloading technology, advanced treatment planning systems, CT/MRI compatible applicators, and advanced imaging platforms, image-guided adaptive brachytherapy treatments (IGABT) have started to play an ever increasing role in modern radiation therapy. The most accurate way to approach IGABT treatment is to provide the infrastructure that combines in a single setting an appropriate imaging device, a treatment planning system, and a treatment unit. The Brachytherapy Suite is not a new concept, yet the modern suites are incorporating state-of-the-art imaging (MRI, CBCT equipped simulators, CT, and /or US) that require correct integration with each other and with the treatment planning and delivery systems. Arguably, an MRI-equipped Brachytherapy Suite is the ideal setup for real-time adaptive brachytherapy treatments. The main impediment to MRI-IGABT adoption is access to MRI scanners. Very few radiation oncology departments currently house MRI scanners, and even fewer in a dedicated Brachytherapy Suite. CBCT equipped simulators are increasingly offered by manufacturers as part of a Brachytherapy Suite installation. If optimized, images acquired can be used for treatment planning, or can be registered with other imaging modalities. This infrastructure is relevant for all forms of brachytherapy, especially those utilizing multi-fractionated courses of treatment such as prostate and cervix. Moreover, for prostate brachytherapy, US imaging systems can be part of the suite to allow for real-time HDR/LDR treatments. Learning Objectives: Understand the adaptive workflow of MR-based IGBT for cervical cancer. Familiarize with commissioning aspects of a CBCT equipped simulator with emphasis on brachytherapy applications Learn about the current status and future developments in US-based prostate brachytherapy

  10. WE-F-BRD-01: HDR Brachytherapy II: Integrating Imaging with HDR

    Energy Technology Data Exchange (ETDEWEB)

    Craciunescu, O [Duke University Medical Center, Durham, NC (United States); Todor, D [Virginia Commonwealth University, Richmond, VA (United States); Leeuw, A de

    2014-06-15

    In recent years, with the advent of high/pulsed dose rate afterloading technology, advanced treatment planning systems, CT/MRI compatible applicators, and advanced imaging platforms, image-guided adaptive brachytherapy treatments (IGABT) have started to play an ever increasing role in modern radiation therapy. The most accurate way to approach IGABT treatment is to provide the infrastructure that combines in a single setting an appropriate imaging device, a treatment planning system, and a treatment unit. The Brachytherapy Suite is not a new concept, yet the modern suites are incorporating state-of-the-art imaging (MRI, CBCT equipped simulators, CT, and /or US) that require correct integration with each other and with the treatment planning and delivery systems. Arguably, an MRI-equipped Brachytherapy Suite is the ideal setup for real-time adaptive brachytherapy treatments. The main impediment to MRI-IGABT adoption is access to MRI scanners. Very few radiation oncology departments currently house MRI scanners, and even fewer in a dedicated Brachytherapy Suite. CBCT equipped simulators are increasingly offered by manufacturers as part of a Brachytherapy Suite installation. If optimized, images acquired can be used for treatment planning, or can be registered with other imaging modalities. This infrastructure is relevant for all forms of brachytherapy, especially those utilizing multi-fractionated courses of treatment such as prostate and cervix. Moreover, for prostate brachytherapy, US imaging systems can be part of the suite to allow for real-time HDR/LDR treatments. Learning Objectives: Understand the adaptive workflow of MR-based IGBT for cervical cancer. Familiarize with commissioning aspects of a CBCT equipped simulator with emphasis on brachytherapy applications Learn about the current status and future developments in US-based prostate brachytherapy.

  11. Independent verification of the delivered dose in High-Dose Rate (HDR) brachytherapy

    International Nuclear Information System (INIS)

    Portillo, P.; Feld, D.; Kessler, J.

    2009-01-01

    An important aspect of a Quality Assurance program in Clinical Dosimetry is an independent verification of the dosimetric calculation done by the Treatment Planning System for each radiation treatment. The present paper is aimed at creating a spreadsheet for the verification of the dose recorded at a point of an implant with radioactive sources and HDR in gynecological injuries. An 192 Ir source automatic differed loading equipment, GammaMedplus model, Varian Medical System with HDR installed at the Angel H. Roffo Oncology Institute has been used. The planning system implemented for getting the dose distribution is the BraquiVision. The sources coordinates as well as those of the calculation point (Rectum) are entered into the Excel-devised verification program by assuming the existence of a point source in each one of the applicators' positions. Such calculation point has been selected as the rectum is an organ at risk, therefore determining the treatment planning. The dose verification is performed at points standing at a sources distance having at least twice the active length of such sources, so they may be regarded as point sources. Most of the sources used in HDR brachytherapy with 192 Ir have a 5 mm active length for all equipment brands. Consequently, the dose verification distance must be at least of 10 mm. (author)

  12. Outcomes Associated With 3 Treatment Schedules of High-Dose-Rate Brachytherapy Monotherapy for Favorable-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Jawad, Maha Saada; Dilworth, Joshua T.; Gustafson, Gary S.; Ye, Hong; Wallace, Michelle [Department of Radiation Oncology, Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States); Martinez, Alvaro [Michigan HealthCare Professionals/21" s" t Century Oncology, Farmington Hills, Michigan (United States); Chen, Peter Y. [Department of Radiation Oncology, Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States); Krauss, Daniel J., E-mail: DKrauss@beaumont.edu [Department of Radiation Oncology, Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States)

    2016-03-15

    Purpose: We report the outcomes associated with 3 high-dose-rate (HDR) brachytherapy regimens used as monotherapy for favorable-risk prostate cancer. Methods and Materials: Four hundred ninety-four patients with stage ≤T2b prostate cancer, Gleason score ≤7, and prostate-specific antigen levels ≤15 ng/mL underwent HDR brachytherapy as monotherapy. Of those, 319 received 38 Gy in 4 fractions, 79 received 24 Gy in 2 fractions, and 96 received 27 Gy in 2 fractions. Acute and chronic genitourinary (GU) and gastrointestinal (GI) toxicities were defined as side effects occurring ≤6 and >6 months, respectively, after radiation therapy (RT) and were graded according to the Common Terminology Criteria for Adverse Events version 3.0. The time to toxicity was calculated from the date of RT completion. Variables were analyzed with χ{sup 2} test. P values <.05 were considered significant. Results: The median overall follow-up time was 4 years (range, 5.5, 3.5, and 2.5 years for 38 Gy, 24 Gy, and 27 Gy, respectively, P<.001). Acute and chronic grade ≥2 GU and GI toxicity profiles were similar among groups. Acceptable rates of grade 2 GU toxicities were seen with overall acute/chronic frequency/urgency, dysuria, retention, incontinence, and hematuria rates of 14%/20%, 6%/7%, 7%/4%, 1.5%/2%, and 1.5%/7%, respectively. Minimal grade 3 and no grade 4 or 5 toxicities were seen. Grade 1, 2, and 3 chronic urethral stricture rates were 0.3%, 2%, and 1%, respectively. All GI toxicities were similar between groups, with overall rates of acute/chronic grade 2 diarrhea, rectal pain/tenesmus, rectal bleeding, and proctitis of 1%/1%, <1%/0.5%, 0%/2%, and <1%/1%, respectively. No grade 3, 4, or 5 toxicities were seen. All comparisons were similar for hormone-naïve patients. The median time to maximal GU/GI toxicity was similar between groups, ranging from 1 to 1.6 to 0.9 to 1.2 years, respectively. There were no differences in clinical outcomes between the 3 groups at 5

  13. Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions

    Energy Technology Data Exchange (ETDEWEB)

    Candela-Juan, C., E-mail: ccanjuan@gmail.com [Radiation Oncology Department, La Fe University and Polytechnic Hospital, Valencia 46026, Spain and National Dosimetry Centre (CND), Valencia 46009 (Spain); Niatsetski, Y. [Elekta Brachytherapy, Veenendaal 3905 TH (Netherlands); Laarse, R. van der [Quality Radiation Therapy BV, Zeist 3707 HB (Netherlands); Granero, D. [Department of Radiation Physics, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Ballester, F. [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Perez-Calatayud, J. [Radiation Oncology Department, La Fe University and Polytechnic Hospital, Valencia 46026, Spain and Department of Radiotherapy, Clínica Benidorm, Benidorm 03501 (Spain); Vijande, J. [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100, Spain and Instituto de Física Corpuscular (UV-CSIC), Burjassot 46100 (Spain)

    2016-04-15

    Purpose: The aims of this study were (i) to design a new high-dose-rate (HDR) brachytherapy applicator for treating surface lesions with planning target volumes larger than 3 cm in diameter and up to 5 cm in size, using the microSelectron-HDR or Flexitron afterloader (Elekta Brachytherapy) with a {sup 192}Ir source; (ii) to calculate by means of the Monte Carlo (MC) method the dose distribution for the new applicator when it is placed against a water phantom; and (iii) to validate experimentally the dose distributions in water. Methods: The PENELOPE2008 MC code was used to optimize dwell positions and dwell times. Next, the dose distribution in a water phantom and the leakage dose distribution around the applicator were calculated. Finally, MC data were validated experimentally for a {sup 192}Ir mHDR-v2 source by measuring (i) dose distributions with radiochromic EBT3 films (ISP); (ii) percentage depth–dose (PDD) curve with the parallel-plate ionization chamber Advanced Markus (PTW); and (iii) absolute dose rate with EBT3 films and the PinPoint T31016 (PTW) ionization chamber. Results: The new applicator is made of tungsten alloy (Densimet) and consists of a set of interchangeable collimators. Three catheters are used to allocate the source at prefixed dwell positions with preset weights to produce a homogenous dose distribution at the typical prescription depth of 3 mm in water. The same plan is used for all available collimators. PDD, absolute dose rate per unit of air kerma strength, and off-axis profiles in a cylindrical water phantom are reported. These data can be used for treatment planning. Leakage around the applicator was also scored. The dose distributions, PDD, and absolute dose rate calculated agree within experimental uncertainties with the doses measured: differences of MC data with chamber measurements are up to 0.8% and with radiochromic films are up to 3.5%. Conclusions: The new applicator and the dosimetric data provided here will be a valuable

  14. Posttraumatic Stress Disorder After High-Dose-Rate Brachytherapy for Cervical Cancer With 2 Fractions in 1 Application Under Spinal/Epidural Anesthesia: Incidence and Risk Factors

    Energy Technology Data Exchange (ETDEWEB)

    Kirchheiner, Kathrin, E-mail: kathrin.kirchheiner@meduniwien.ac.at [Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/General Hospital of Vienna, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna, Vienna (Austria); Czajka-Pepl, Agnieszka [Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/General Hospital of Vienna, Vienna (Austria); Ponocny-Seliger, Elisabeth [Department of Psychology, Sigmund Freud Private University Vienna, Vienna (Austria); Scharbert, Gisela; Wetzel, Léonore [Department of Anaesthesia, General Intensive Care and Pain Management, Medical University of Vienna/General Hospital of Vienna, Vienna (Austria); Nout, Remi A. [Department of Clinical Oncology, Leiden University Medical Center, Leiden (Netherlands); Sturdza, Alina [Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/General Hospital of Vienna, Vienna (Austria); Dimopoulos, Johannes C. [Metropolitan Hospital, Athens (Greece); Dörr, Wolfgang; Pötter, Richard [Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/General Hospital of Vienna, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna, Vienna (Austria)

    2014-06-01

    Purpose: To investigate the psychological consequences of high-dose-rate brachytherapy with 2 fractions in 1 application under spinal/epidural anesthesia in the treatment of locally advanced cervical cancer. Methods and Materials: In 50 patients with locally advanced cervical cancer, validated questionnaires were used for prospective assessment of acute and posttraumatic stress disorder (ASD/PTSD) (Impact of Event Scale–Revision), anxiety/depression (Hospital Anxiety and Depression Scale), quality of life (European Organization for Research and Treatment of Cancer Quality of Life Questionnaire Core 30/Cervical Cancer 24), physical functioning (World Health Organization performance status), and pain (visual analogue scale), before and during treatment and 1 week and 3 months after treatment. Qualitative interviews were recorded in open format for content analysis. Results: Symptoms of ASD occurred in 30% of patients 1 week after treatment; and of PTSD in 41% 3 months after treatment in association with this specific brachytherapy procedure. Pretreatment predictive variables explain 82% of the variance of PTSD symptoms. Helpful experiences were the support of the treatment team, psychological support, and a positive attitude. Stressful factors were pain, organizational problems during treatment, and immobility between brachytherapy fractions. Conclusions: The specific brachytherapy procedure, as performed in the investigated mono-institutional setting with 2 fractions in 1 application under spinal/epidural anesthesia, bears a considerable risk of traumatization. The source of stress seems to be not the brachytherapy application itself but the maintenance of the applicator under epidural anesthesia in the time between fractions. Patients at risk may be identified before treatment, to offer targeted psycho-social support. The patients' open reports regarding helpful experiences are an encouraging feedback for the treatment team; the reported stressful

  15. External beam radiation therapy and a low-dose-rate brachytherapy boost without or with androgen deprivation therapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Strom, Tobin J.; Hutchinson, Sean Z.; Shrinath, Kushagra; Cruz, Alex A.; Figura, Nicholas B.; Nethers, Kevin; Biagioli, Matthew C.; Fernandez, Daniel C.; Heysek, Randy V.; Wilder, Richard B., E-mail: richard.wilder@moffitt.org [Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States)

    2014-07-15

    Purpose: To assess outcomes with external beam radiation therapy (EBRT) and a low-dose-rate (LDR) brachytherapy boost without or with androgen deprivation therapy (ADT) for prostate cancer. Materials and Methods: From January 2001 through August 2011, 120 intermediate-risk or high-risk prostate cancer patients were treated with EBRT to a total dose of 4,500 cGy in 25 daily fractions and a palladium-103 LDR brachytherapy boost of 10,000 cGy (n = 90) or an iodine-125 LDR brachytherapy boost of 11,000 cGy (n = 30). ADT, consisting of a gonadotropin-releasing hormone agonist ± an anti-androgen, was administered to 29/92 (32%) intermediate-risk patients for a median duration of 4 months and 26/28 (93%) high-risk patients for a median duration of 28 months. Results: Median follow-up was 5.2 years (range, 1.1-12.8 years). There was no statistically-significant difference in biochemical disease-free survival (bDFS), distant metastasis-free survival (DMFS), or overall survival (OS) without or with ADT. Also, there was no statistically-significant difference in bDFS, DMFS, or OS with a palladium-103 vs. an iodine-125 LDR brachytherapy boost. Conclusions: There was no statistically-significant difference in outcomes with the addition of ADT, though the power of the current study was limited. The Radiation Therapy Oncology Group 0815 and 0924 phase III trials, which have accrual targets of more than 1,500 men, will help to clarify the role ADT in locally-advanced prostate cancer patients treated with EBRT and a brachytherapy boost. Palladium-103 and iodine-125 provide similar bDFS, DMFS, and OS. (author)

  16. Posttraumatic Stress Disorder After High-Dose-Rate Brachytherapy for Cervical Cancer With 2 Fractions in 1 Application Under Spinal/Epidural Anesthesia: Incidence and Risk Factors

    International Nuclear Information System (INIS)

    Kirchheiner, Kathrin; Czajka-Pepl, Agnieszka; Ponocny-Seliger, Elisabeth; Scharbert, Gisela; Wetzel, Léonore; Nout, Remi A.; Sturdza, Alina; Dimopoulos, Johannes C.; Dörr, Wolfgang; Pötter, Richard

    2014-01-01

    Purpose: To investigate the psychological consequences of high-dose-rate brachytherapy with 2 fractions in 1 application under spinal/epidural anesthesia in the treatment of locally advanced cervical cancer. Methods and Materials: In 50 patients with locally advanced cervical cancer, validated questionnaires were used for prospective assessment of acute and posttraumatic stress disorder (ASD/PTSD) (Impact of Event Scale–Revision), anxiety/depression (Hospital Anxiety and Depression Scale), quality of life (European Organization for Research and Treatment of Cancer Quality of Life Questionnaire Core 30/Cervical Cancer 24), physical functioning (World Health Organization performance status), and pain (visual analogue scale), before and during treatment and 1 week and 3 months after treatment. Qualitative interviews were recorded in open format for content analysis. Results: Symptoms of ASD occurred in 30% of patients 1 week after treatment; and of PTSD in 41% 3 months after treatment in association with this specific brachytherapy procedure. Pretreatment predictive variables explain 82% of the variance of PTSD symptoms. Helpful experiences were the support of the treatment team, psychological support, and a positive attitude. Stressful factors were pain, organizational problems during treatment, and immobility between brachytherapy fractions. Conclusions: The specific brachytherapy procedure, as performed in the investigated mono-institutional setting with 2 fractions in 1 application under spinal/epidural anesthesia, bears a considerable risk of traumatization. The source of stress seems to be not the brachytherapy application itself but the maintenance of the applicator under epidural anesthesia in the time between fractions. Patients at risk may be identified before treatment, to offer targeted psycho-social support. The patients' open reports regarding helpful experiences are an encouraging feedback for the treatment team; the reported stressful

  17. Five Years' Experience Treating Locally Advanced Cervical Cancer With Concurrent Chemoradiotherapy and High-Dose-Rate Brachytherapy: Results From a Single Institution

    International Nuclear Information System (INIS)

    Parker, Kate; Gallop-Evans, Eve; Hanna, Louise; Adams, Malcolm

    2009-01-01

    Purpose: To assess the clinical outcomes after concurrent cisplatin chemotherapy and radiotherapy (RT) followed by high-dose-rate brachytherapy for locally advanced carcinoma of the cervix and perform a multivariate analysis of the prognostic factors. Methods and Materials: The outcomes were analyzed for all women treated between 1999 and 2004 with concurrent cisplatin chemotherapy and RT followed by high-dose-rate brachytherapy. Kaplan-Meier analysis was used for overall survival (OS), local control (LC), and distant control (DC). The Cox proportional hazards model was used to perform multivariate analysis of the prognostic variables. Results: The standard regimen comprised whole pelvic external RT 45 Gy in 25 fractions with concurrent weekly cisplatin 40 mg/m 2 , followed by four high-dose-rate brachytherapy insertions of 6 Gy. Patients with radiologically enlarged para-aortic lymph nodes underwent extended-field RT. Of 92 patients, the OS rate was 72% at 2 years and 55% at 5 years. The LC rate was 76% at 2 years and 67% at 5 years. The DC rate was 68% at 2 years and 48% at 5 years. The most important prognostic factor for OS, LC, and DC was the pretreatment hemoglobin. For OS, the tumor size and the presence of enlarged lymph nodes were also important. For LC, the number of brachytherapy insertions was important; and for DC, the number of chemotherapy treatments was important. Of the patients, 4% experienced late Grade 3 or 4 toxicity. Conclusion: The results of our study have shown that the regimen is effective, with acceptable long-term side effects. In this cohort, the most important prognostic factor was the pretreatment hemoglobin level, a disease-related factor. However, more effective systemic treatments are needed.

  18. Role of vaginal pallor reaction in predicting late vaginal stenosis after high-dose-rate brachytherapy in treatment-naive patients with cervical cancer.

    Science.gov (United States)

    Yoshida, Ken; Yamazaki, Hideya; Nakamura, Satoaki; Masui, Koji; Kotsuma, Tadayuki; Akiyama, Hironori; Tanaka, Eiichi; Yoshikawa, Nobuhiko; Uesugi, Yasuo; Shimbo, Taiju; Narumi, Yoshifumi; Yoshioka, Yasuo

    2015-07-01

    To assess actual rates of late vaginal stenosis and identify predisposing factors for complications among patients with previously untreated cervical cancer following high-dose-rate brachytherapy. We performed longitudinal analyses of 57 patients using the modified Dische score at 6, 12, 18, 24, 36, and 60 months after treatment, which consisted of 15 interstitial brachytherapys and 42 conventional intracavitary brachytherapys, with a median follow-up time of 36 months (range, 6 to 144 months). More than half of the patients developed grade 1 (mild) vaginal stenosis within the first year of follow-up, and grade 2 (97.5%, moderate) to grade 3 (severe) stenosis gradually increased with time. Actual stenosis rates for grade 1, 2, and 3 were 97.5% (95% confidence interval [CI], 92.7 to 97.5), 60.7% (95% CI, 42.2 to 79.3), and 7.4% (95% CI, 0 to 18.4) at 3 years after treatment. Pallor reaction grade 2-3 at 6 months was only a statistically significant predisposing factor for grade 2-3 late vaginal stenosis 3 years or later with a hazard ratio of 3.48 (95% CI, 1.32 to 9.19; p=0.018) by a multivariate Cox proportional hazard model. Patients with grade 0-1 pallor reaction at 6 months showed a grade ≥2 vaginal stenosis rate of 53%, whereas the grade 2-3 pallor reaction group achieved a grade ≥2 vaginal stenosis rate at 3 years at 100% (p=0.001). High-dose-rate brachytherapy was associated with high incidence of late vaginal stenosis. Pallor reaction grade 2-3 at 6 months was predictive of late grade 2-3 vaginal stenosis at 3 years after treatment. These findings should prove helpful for patient counseling and preventive intervention.

  19. High-Dose-Rate Brachytherapy Alone for Localized Prostate Cancer in Patients at Moderate or High Risk of Biochemical Recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Hoskin, Peter [Cancer Centre, Mount Vernon Hospital, Northwood, Middlesex (United Kingdom); Rojas, Ana, E-mail: arc03@btconnect.com [Cancer Centre, Mount Vernon Hospital, Northwood, Middlesex (United Kingdom); Lowe, Gerry; Bryant, Linda; Ostler, Peter; Hughes, Rob; Milner, Jessica; Cladd, Helen [Cancer Centre, Mount Vernon Hospital, Northwood, Middlesex (United Kingdom)

    2012-03-15

    Purpose: To evaluate genitourinary (GU) and gastrointestinal (GI) morbidity and biochemical control of disease in patients with localized prostate adenocarcinoma treated with escalating doses per fraction of high-dose rate brachytherapy alone. Methods and Materials: A total of 197 patients were treated with 34 Gy in four fractions, 36 Gy in four fractions, 31.5 Gy in three fractions, or 26 Gy in two fractions. Median follow-up times were 60, 54, 36, and 6 months, respectively. Results: Incidence of early Grade {>=} 3 GU morbidity was 3% to 7%, and Grade 4 was 0% to 4%. During the first 12 weeks, the highest mean International Prostate Symptom Score (IPSS) value was 14, and between 6 months and 5 years it was 8. Grade 3 or 4 early GI morbidity was not observed. The 3-year actuarial rate of Grade 3 GU was 3% to 16%, and was 3% to 7% for strictures requiring surgery (4-year rate). An incidence of 1% Grade 3 GI events was seen at 3 years. Late Grade 4 GU or GI events were not observed. At 3 years, 99% of patients with intermediate-risk and 91% with high-risk disease were free of biochemical relapse (log-rank p = 0.02). Conclusions: There was no significant difference in urinary and rectal morbidity between schedules. Biochemical control of disease in patients with intermediate and high risk of relapse was good.

  20. WE-G-BRA-07: Analyzing the Safety Implications of a Brachytherapy Process Improvement Project Utilizing a Novel System-Theory-Based Hazard-Analysis Technique

    Energy Technology Data Exchange (ETDEWEB)

    Tang, A; Samost, A [Massachusetts Institute of Technology, Cambridge, Massachusetts (United States); Viswanathan, A; Cormack, R; Damato, A [Dana-Farber Cancer Institute - Brigham and Women’s Hospital, Boston, MA (United States)

    2015-06-15

    Purpose: To investigate the hazards in cervical-cancer HDR brachytherapy using a novel hazard-analysis technique, System Theoretic Process Analysis (STPA). The applicability and benefit of STPA to the field of radiation oncology is demonstrated. Methods: We analyzed the tandem and ring HDR procedure through observations, discussions with physicists and physicians, and the use of a previously developed process map. Controllers and their respective control actions were identified and arranged into a hierarchical control model of the system, modeling the workflow from applicator insertion through initiating treatment delivery. We then used the STPA process to identify potentially unsafe control actions. Scenarios were then generated from the identified unsafe control actions and used to develop recommendations for system safety constraints. Results: 10 controllers were identified and included in the final model. From these controllers 32 potentially unsafe control actions were identified, leading to more than 120 potential accident scenarios, including both clinical errors (e.g., using outdated imaging studies for planning), and managerial-based incidents (e.g., unsafe equipment, budget, or staffing decisions). Constraints identified from those scenarios include common themes, such as the need for appropriate feedback to give the controllers an adequate mental model to maintain safe boundaries of operations. As an example, one finding was that the likelihood of the potential accident scenario of the applicator breaking during insertion might be reduced by establishing a feedback loop of equipment-usage metrics and equipment-failure reports to the management controller. Conclusion: The utility of STPA in analyzing system hazards in a clinical brachytherapy system was demonstrated. This technique, rooted in system theory, identified scenarios both technical/clinical and managerial in nature. These results suggest that STPA can be successfully used to analyze safety in

  1. Use of CT or MR dosimetry in high dose rate (HDR) brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Liu, C.; Das, R.; See, A.; Duchesne, G.M.; Van Dyk, S.; Tai, K.H.

    2003-01-01

    Brachytherapy (BT) has, in recent years, become a well-utilised treatment option for prostate cancer. Tumour control probability relies on accurate dosimetry, which in turn relies on the accurate definition of the prostate gland. In external beam radiotherapy and BT, MRI has been shown to be a superior imaging modality when delineating the prostate gland especially at the apex. To date, data on MRI planning in prostate BT has focussed mainly on permanent interstitial implants. No data currently exists comparing MRI vs CT planning in HDR BT and its subsequent impact on prostate dosimetry. To determine the effects of MRI vs CT in HDR BT with respect to prostatic volumes and normal tissue doses, with the evaluations made using dose-volume histograms (DVH). Dosimetry parameters derived using CT and MRI (T2 weighted) scans of 11 patients who had received TRUS guided implants for HDR BT, were compared using the PlatoTM computer planning system. Treatment plans were generated on volumes marked by the same radiation oncologist for each patient. Comparison was made of the treatment plans (dosimetry) between: 1. CT generated plans; 2. CT generated plans assessed using MRI marked volumes and 3. MRI generated plans. We confirm the previously reported results that CT scans can overestimate prostatic volumes compared with MRI. Variations were noted in CT and MRI based plans that may allow improved sparing of the rectum and urethra when using MRI planning. The main disadvantages of using MRI scans are access to facilities as well as identifying a dummy source to adequately define the tips of our catheters. It is feasible to utilise MRI scans for HDR BT planning. The clearer definition of anatomical structures has added advantages when contouring the prostate

  2. Verification of the calculation program for brachytherapy planning system of high dose rate (PLATO); Programa de verificacion del calculo para un sistema de planificacion de braquiterapia de alta tasa de dosis (PLATO)

    Energy Technology Data Exchange (ETDEWEB)

    Almansa, J.; Alaman, C.; Perez-Alija, J.; Herrero, C.; Real, R. del; Ososrio, J. L.

    2011-07-01

    In our treatments are performed brachytherapy high dose rate since 2007. The procedures performed include gynecological intracavitary treatment and interstitial. The treatments are performed with a source of Ir-192 activity between 5 and 10 Ci such that small variations in treatment times can cause damage to the patient. In addition the Royal Decree 1566/1998 on Quality Criteria in radiotherapy establishes the need to verify the monitor units or treatment time in radiotherapy and brachytherapy. All this justifies the existence of a redundant system for brachytherapy dose calculation that can reveal any abnormality is present.

  3. Development of brachytherapy medium doserate

    International Nuclear Information System (INIS)

    Atang Susila; Ari Satmoko; Ahmad Rifai; Kristiyanti

    2010-01-01

    Brachytherapy has proven to be an effective treatment for different types of cancers and it become a common treatment modality in most radiotherapy clinics. PRPN has had experience in development of Low Dose Rate Brachytherapy for cervix cancer treatment. However the treatment process using LDR device needs 5 hours in time that the patient feel uncomfort. Therefore PRPN develops Medium Dose Rate Brachytherapy with radiation activity not more than 5 Currie. The project is divided into two stages. Purchasing of TPS software and TDS design are held in 2010, and the construction will be in 2011. (author)

  4. Verification of radiation dose to a and b position during low dose rate 137cs brachytherapy in Bangladesh

    International Nuclear Information System (INIS)

    Roy, S.; Begur, M.

    2001-01-01

    A manual low dose rate 137Cs brachytherapy consists of two sets viz. 440 mCi (tandem 120, 40,40, 40,40 and ovoids 40,40 mCi each) and 360 mCi (tandem 120, 40,40 mCi and ovoids 40,40 mCi each) having the dose rates at A were 155.2 c Gy/hr and 140.8 c Gy/hr respectively on June 1996) was supplied by the Bhabha Atomic Research Centre (BARC), Mumbai, India and are being used in the Delta Medical Centre Limited, Mirpur, Dhaka, Bangladesh for gynecological insertion. BARC also supplied the operation manual quoting the dose at point A and B of cervix of the patient only for straight uterine tubes and separation between vaginal ovoids of 2, 3 and 4 cm. BARC also mentioned that the dose at A and B are within 1-2 % of the mean value. Manual calculation was done to compare the dose at point A and B for ten intracavitary insertions in the hospital to compare those with the value supplied by the BARC. It was found that dose varied at point A from +0.46 % to +9.11 % for eight patients and -3.4 % to -5.96 % for two patients with quoted value. Dose at B varied from +0.59 % to +9.8 % for nine patients and -10.94 % for one patient with the quoted value supplied by the supplier. This is not unusual because the tandem used for treatment were with different angles such as, 15 degree, 30 degree etc. as per anatomy of the patient. Moreover, the tolerance dose of the fornix region is much higher (about 140 Gy) than that of the other critical organ. Overall prognosis of the patients, treated so far, using this manual brachytherapy and performing manual calculation is satisfactory. So, the results shows a good result with the manual treatment planning

  5. Set the initial reference state of a team brachytherapy high dose rate; Establecimiento del estado de referencia inicial de un equipo de braquiterapia de alta tasa de dosis

    Energy Technology Data Exchange (ETDEWEB)

    Clemente Gutierrez, F.; Diaz Fuentes, R.; Cabello Murillo, E.; Casa de Julian, M. A. de la; Ferrando Sanchez, A.; Adaimi Hernandez, P.

    2011-07-01

    You have set the initial reference state for a team of high-rate brachytherapy doses according to the recommendations made in the text used as a reference, being always within the functional tolerances established for the team, or the number associated with each test. The team was ready for clinical use under the provisions of Royal Decree 1566/1998 of Quality Control in Radiotherapy.

  6. Postoperative HDR afterloading brachytherapy: Vaginal tumor recurrence rates in patients with endometrial carcinoma dependent on treatment volumes

    International Nuclear Information System (INIS)

    Kloetzer, K.H.; Guenther, R.; Wendt, T.

    1997-01-01

    Patients and Method: At Jena University, Department of Radiotherapy, from 1981 to 1990 108 patients with endometrical carcinoma were postoperatively treated with high dose radiation brachytherapy of the vagina without additional percutaneous radiotherapy. Histology showed more or less differenciated adenocarcinoma in 90% of all patients, all patients were postoperatively stage I or II without proven lymphatic metastases. Dependent on individual figures patients were distributed to 3 different gorups: group A: 4 x 10 Gy, tissue-thickness of 1 cm (vaginal apex) respectively 0.5 cm (lower vaginal walls); group B: 4 x 10 Gy, tissue thickness of 1 cm (upper vaginal wall); group C: 4 x 10 Gy, tissue-thickness of 0.5 cm (both excluding the lower vaginal walls). Results: Both 3-year survival rates (group A: 96.6%, group B: 96.9%, group C: 97.7%) and tumor relapse rates of the vaginal apex (group A: 0, group B: 3.1%, group C: 2.2%) don't show significant differences. No case of local tumor recurrence was seen in the upper 2/3 of the vagina and the pelvic walls. Late side effects concerning bladder and rectum (grade III to IV, EORTC/RTOG) could be minimized by reducing the treatment volume (group A: 6.8%/12.6%, group B: 6,2%/3.1%, group C: 2.2%/0). (orig./AJ) [de

  7. Novel treatment options for nonmelanoma skin cancer: focus on electronic brachytherapy

    Directory of Open Access Journals (Sweden)

    Kasper ME

    2015-11-01

    Full Text Available Michael E Kasper,1,2 Ahmed A Chaudhary3 1Department of Radiation Oncology, Lynn Cancer Institute at Boca Raton Regional Hospital, Boca Raton, 2Charles E. Schmidt College of Medicine, Florida Atlantic University, FL, 3North Main Radiation Oncology, Warren Alpert School of Medicine, Brown University, RI, USA Abstract: Nonmelanoma skin cancer (NMSC is an increasing health care issue in the United States, significantly affecting quality of life and impacting health care costs. Radiotherapy has a long history in the treatment of NMSC. Shortly after the discovery of X-rays and 226Radium, physicians cured patients with NMSC using these new treatments. Both X-ray therapy and brachytherapy have evolved over the years, ultimately delivering higher cure rates and lower toxicity. Electronic brachytherapy for NMSC is based on the technical and clinical data obtained from radionuclide skin surface brachytherapy and the small skin surface applicators developed over the past 25 years. The purpose of this review is to introduce electronic brachytherapy in the context of the history, data, and utilization of traditional radiotherapy and brachytherapy. Keywords: electronic brachytherapy, superficial radiotherapy, skin surface brachytherapy, electron beam therapy, nonmelanoma skin cancer, basal cell carcinoma, squamous cell carcinoma

  8. Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGE® radiochromic plastic

    International Nuclear Information System (INIS)

    Palmer, A. L.; Di Pietro, P.; Alobaidli, S.; Issa, F.; Doran, S.; Bradley, D.; Nisbet, A.

    2013-01-01

    Purpose: Dose distribution measurement in clinical high dose rate (HDR) brachytherapy is challenging, because of the high dose gradients, large dose variations, and small scale, but it is essential to verify accurate treatment planning and treatment equipment performance. The authors compare and evaluate three dosimetry systems for potential use in brachytherapy dose distribution measurement: Ge-doped optical fibers, EBT3 Gafchromic film with multichannel analysis, and the radiochromic material PRESAGE ® with optical-CT readout. Methods: Ge-doped SiO 2 fibers with 6 μm active core and 5.0 mm length were sensitivity-batched and their thermoluminescent properties used via conventional heating and annealing cycles. EBT3 Gafchromic film of 30 μm active thickness was calibrated in three color channels using a nominal 6 MV linear accelerator. A 48-bit transmission scanner and advanced multichannel analysis method were utilized to derive dose measurements. Samples of the solid radiochromic polymer PRESAGE ® , 60 mm diameter and 100 mm height, were analyzed with a parallel beam optical CT scanner. Each dosimetry system was used to measure the dose as a function of radial distance from a Co-60 HDR source, with results compared to Monte Carlo TG-43 model data. Each system was then used to measure the dose distribution along one or more lines through typical clinical dose distributions for cervix brachytherapy, with results compared to treatment planning system (TPS) calculations. Purpose-designed test objects constructed of Solid Water and held within a full-scatter water tank were utilized. Results: All three dosimetry systems reproduced the general shape of the isolated source radial dose function and the TPS dose distribution. However, the dynamic range of EBT3 exceeded those of doped optical fibers and PRESAGE ® , and the latter two suffered from unacceptable noise and artifact. For the experimental conditions used in this study, the useful range from an isolated

  9. Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGE® radiochromic plastic.

    Science.gov (United States)

    Palmer, A L; Di Pietro, P; Alobaidli, S; Issa, F; Doran, S; Bradley, D; Nisbet, A

    2013-06-01

    Dose distribution measurement in clinical high dose rate (HDR) brachytherapy is challenging, because of the high dose gradients, large dose variations, and small scale, but it is essential to verify accurate treatment planning and treatment equipment performance. The authors compare and evaluate three dosimetry systems for potential use in brachytherapy dose distribution measurement: Ge-doped optical fibers, EBT3 Gafchromic film with multichannel analysis, and the radiochromic material PRESAGE(®) with optical-CT readout. Ge-doped SiO2 fibers with 6 μm active core and 5.0 mm length were sensitivity-batched and their thermoluminescent properties used via conventional heating and annealing cycles. EBT3 Gafchromic film of 30 μm active thickness was calibrated in three color channels using a nominal 6 MV linear accelerator. A 48-bit transmission scanner and advanced multichannel analysis method were utilized to derive dose measurements. Samples of the solid radiochromic polymer PRESAGE(®), 60 mm diameter and 100 mm height, were analyzed with a parallel beam optical CT scanner. Each dosimetry system was used to measure the dose as a function of radial distance from a Co-60 HDR source, with results compared to Monte Carlo TG-43 model data. Each system was then used to measure the dose distribution along one or more lines through typical clinical dose distributions for cervix brachytherapy, with results compared to treatment planning system (TPS) calculations. Purpose-designed test objects constructed of Solid Water and held within a full-scatter water tank were utilized. All three dosimetry systems reproduced the general shape of the isolated source radial dose function and the TPS dose distribution. However, the dynamic range of EBT3 exceeded those of doped optical fibers and PRESAGE(®), and the latter two suffered from unacceptable noise and artifact. For the experimental conditions used in this study, the useful range from an isolated HDR source was 5-40 mm for

  10. Late toxicity and five year outcomes after high-dose-rate brachytherapy as a monotherapy for localized prostate cancer

    International Nuclear Information System (INIS)

    Ghadjar, Pirus; Oesch, Sebastian L; Rentsch, Cyrill A; Isaak, Bernhard; Cihoric, Nikola; Manser, Peter; Thalmann, George N; Aebersold, Daniel M

    2014-01-01

    To determine the 5-year outcome after high-dose-rate brachytherapy (HDR-BT) as a monotherapy. Between 10/2003 and 06/2006, 36 patients with low (28) and intermediate (8) risk prostate cancer were treated by HDR-BT monotherapy. All patients received one implant and 4 fractions of 9.5 Gy within 48 hours for a total prescribed dose (PD) of 38 Gy. Five patients received concomitant androgen deprivation therapy (ADT). Toxicity was scored according to the common terminology criteria for adverse events from the National Cancer Institute (CTCAE) version 3.0. Biochemical recurrence was defined according to the Phoenix criteria and analyzed using the Kaplan Meier method. Predictors for late grade 3 GU toxicity were analyzed using univariate and multivariate Cox regression analyses. The median follow-up was 6.9 years (range, 1.5-8.0 years). Late grade 2 and 3 genitourinary (GU) toxicity was observed in 10 (28%) and 7 (19%) patients, respectively. The actuarial proportion of patients with late grade 3 GU toxicity at 5 years was 17.7%. Late grade 2 and 3 gastrointestinal (GI) toxicities were not observed. The crude erectile function preservation rate in patients without ADT was 75%. The 5 year biochemical recurrence-free survival (bRFS) rate was 97%. Late grade 3 GU toxicity was associated with the urethral volume (p = 0.001) and the urethral V 120 (urethral volume receiving ≥120% of the PD; p = 0.0005) after multivariate Cox regression. After HDR-BT monotherapy late grade 3 GU was observed relatively frequently and was associated with the urethral V 120 . GI toxicity was negligible, the erectile function preservation rate and the bRFS rate was excellent

  11. Periodical assessment of genitourinary and gastrointestinal toxicity in patients who underwent prostate low-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Tanaka, Nobumichi; Asakawa, Isao; Anai, Satoshi; Hirayama, Akihide; Hasegawa, Masatoshi; Konishi, Noboru; Fujimoto, Kiyohide

    2013-01-01

    To compare the periodical incidence rates of genitourinary (GU) and gastrointestinal (GI) toxicity in patients who underwent prostate low-dose-rate brachytherapy between the monotherapy group (seed implantation alone) and the boost group (in combination with external beam radiation therapy (EBRT)). A total of 218 patients with a median follow-up of 42.5 months were enrolled. The patients were divided into 2 groups by treatment modality, namely, the monotherapy group (155 patients) and the boost group (63 patients). The periodical incidence rates of GU and GI toxicity were separately evaluated and compared between the monotherapy group and the boost group using the National Cancer Institute - Common Terminology Criteria for Adverse Events, version 3.0. To elucidate an independent factor among clinical and postdosimetric parameters to predict grade 2 or higher GU and GI toxicity in the acute and late phases, univariate and multivariate logistic regression analyses were carried out. Of all patients, 78.0% showed acute GU toxicity, and 7.8% showed acute GI toxicity, while 63.8% showed late GU toxicity, and 21.1% showed late GI toxicity. The incidence rates of late GU and GI toxicity were significantly higher in the boost group. Multivariate analysis showed that the International Prostate Symptom Score (IPSS) before seed implantation was a significant parameter to predict acute GU toxicity, while there were no significant predictive parameters for acute GI toxicity. On the other hand, combination with EBRT was a significant predictive parameter for late GU toxicity, and rectal volume (mL) receiving 100% of the prescribed dose (R100) was a significant predictive parameter for late GI toxicity. The boost group showed higher incidence rates of both GU and GI toxicity. Higher IPSS before seed implantation, combination with EBRT and a higher R100 were significant predictors for acute GU, late GU and late GI toxicity

  12. The Effect of Dose and Quality Assurance in Early Prostate Cancer Treated with Low Dose Rate Brachytherapy as Monotherapy.

    Science.gov (United States)

    Henry, A M; Rodda, S L; Mason, M; Musunuru, H; Al-Qaisieh, B; Bownes, P; Smith, J; Franks, K; Carey, B; Bottomley, D

    2015-07-01

    To examine the relationship between post-implant computed tomography dosimetry and long-term prostate-specific antigen relapse-free survival in patients treated with iodine 125 (I-125) low dose rate prostate brachytherapy as monotherapy and, second, to audit recent practice against Royal College of Radiologists' (RCR) guidelines after the re-introduction of post-implant dosimetry for all patients in our centre. Between March 1995 and September 2007, 2157 consecutive patients with localised prostate cancer underwent I-125 permanent prostate brachytherapy as monotherapy in a single UK centre. All patients were transrectal ultrasound planned delivering a 145 Gy (TG 43) minimum peripheral dose. None received supplemental external beam radiotherapy. Post-implant computed tomography-based dosimetry was undertaken between 4 and 6 weeks after treatment and was available for 711 (33%). Outcomes were analysed in terms of the relationship of D90 to prostate-specific antigen relapse-free survival (nadir 2+ definition) and all patients had a minimum follow-up of 5 years. For contemporary patients from 2011, quality metrics from post-implant computed tomography as defined by RCR guidelines are presented. A mean D90 of 138.7 Gy (standard deviation 24.7) was achieved for the historic cohort. Biochemical control at 10 years was 76% in patients with D90 > 140 Gy and 68% in those with D90 standard deviation) D90 has increased from 154 (15.3) Gy in 2011 to 164 (13.5) Gy in 2013. Similarly, an increase in the mean (standard deviation) V100 from 92 (4.4) to 95 (3.2) % is noted over time. No difference between clinicians was noted. D90 values of less than 140 Gy continue to be predictive of increased risk of recurrence of prostate cancer across risk groups with longer follow-up. Quality assurance can be used to ensure improved and consistent implant quality in a team with multiple clinicians. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights

  13. SU-E-J-232: Feasibility of MRI-Based Preplan On Low Dose Rate Prostate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Y; Tward, J; Rassiah-Szegedi, P; Zhao, H; Sarkar, V; Huang, L; Szegedi, M; Kokeny, K; Salter, B [University of Utah Huntsman Cancer Institute, Salt Lake City, UT (United States)

    2015-06-15

    Purpose: To investigate the feasibility of using MRI-based preplan for low dose rate prostate brachytherapy. Methods: 12 patients who received transrectal ultrasound (TRUS) guided prostate brachytherapy with Pd-103 were retrospectively studied. Our care-standard of the TRUS-based preplan served as the control. One or more prostate T2-weighted wide and/or narrow-field of view MRIs obtained within the 3 months prior to the implant were imported into the MIM Symphony software v6.3 (MIM Software Inc., Cleveland, OH) for each patient. In total, 37 MRI preplans (10 different image sequences with average thickness of 4.8mm) were generated. The contoured prostate volume and the seed counts required to achieve adequate dosimetric coverage from TRUS and MRI preplans were compared for each patient. The effects of different MRI sequences and image thicknesses were also investigated statistically using Student’s t-test. Lastly, the nomogram from the MRI preplan and TRUS preplan from our historical treatment data were compared. Results: The average prostate volume contoured on the TRUS and MRI were 26.6cc (range: 12.6∼41.3cc), and 27.4 cc (range: 14.3∼50.0cc), respectively. Axial MRI thicknesses (range: 3.5∼8.1mm) did not significantly affect the contoured volume or the number of seeds required on the preplan (R2 = 0.0002 and 0.0012, respectively). Four of the MRI sequences (AX-T2, AX-T2-Whole-Pelvis, AX-T2-FSE, and AXIALT2- Hi-Res) showed statistically significant better prostate volume agreement with TRUS than the other seven sequences (P <0.01). Nomogram overlay between the MRI and TRUS preplans showed good agreement; indicating volumes contoured on MRI preplan scan reliably predict how many seeds are needed for implant. Conclusion: Although MRI does not allow for determination of the actual implant geometry, it can give reliable volumes for seed ordering purposes. Our future work will investigate if MRI is sufficient to reliably replace TRUS preplanning in patients

  14. Evaluation of a Machine-Learning Algorithm for Treatment Planning in Prostate Low-Dose-Rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Nicolae, Alexandru [Department of Physics, Ryerson University, Toronto, Ontario (Canada); Department of Medical Physics, Odette Cancer Center, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Morton, Gerard; Chung, Hans; Loblaw, Andrew [Department of Radiation Oncology, Odette Cancer Center, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Jain, Suneil; Mitchell, Darren [Department of Clinical Oncology, The Northern Ireland Cancer Centre, Belfast City Hospital, Antrim, Northern Ireland (United Kingdom); Lu, Lin [Department of Radiation Therapy, Odette Cancer Center, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Helou, Joelle; Al-Hanaqta, Motasem [Department of Radiation Oncology, Odette Cancer Center, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Heath, Emily [Department of Physics, Carleton University, Ottawa, Ontario (Canada); Ravi, Ananth, E-mail: ananth.ravi@sunnybrook.ca [Department of Medical Physics, Odette Cancer Center, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada)

    2017-03-15

    Purpose: This work presents the application of a machine learning (ML) algorithm to automatically generate high-quality, prostate low-dose-rate (LDR) brachytherapy treatment plans. The ML algorithm can mimic characteristics of preoperative treatment plans deemed clinically acceptable by brachytherapists. The planning efficiency, dosimetry, and quality (as assessed by experts) of preoperative plans generated with an ML planning approach was retrospectively evaluated in this study. Methods and Materials: Preimplantation and postimplantation treatment plans were extracted from 100 high-quality LDR treatments and stored within a training database. The ML training algorithm matches similar features from a new LDR case to those within the training database to rapidly obtain an initial seed distribution; plans were then further fine-tuned using stochastic optimization. Preimplantation treatment plans generated by the ML algorithm were compared with brachytherapist (BT) treatment plans in terms of planning time (Wilcoxon rank sum, α = 0.05) and dosimetry (1-way analysis of variance, α = 0.05). Qualitative preimplantation plan quality was evaluated by expert LDR radiation oncologists using a Likert scale questionnaire. Results: The average planning time for the ML approach was 0.84 ± 0.57 minutes, compared with 17.88 ± 8.76 minutes for the expert planner (P=.020). Preimplantation plans were dosimetrically equivalent to the BT plans; the average prostate V150% was 4% lower for ML plans (P=.002), although the difference was not clinically significant. Respondents ranked the ML-generated plans as equivalent to expert BT treatment plans in terms of target coverage, normal tissue avoidance, implant confidence, and the need for plan modifications. Respondents had difficulty differentiating between plans generated by a human or those generated by the ML algorithm. Conclusions: Prostate LDR preimplantation treatment plans that have equivalent quality to plans created

  15. A hybrid evolutionary algorithm for multi-objective anatomy-based dose optimization in high-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Lahanas, M; Baltas, D; Zamboglou, N

    2003-01-01

    Multiple objectives must be considered in anatomy-based dose optimization for high-dose-rate brachytherapy and a large number of parameters must be optimized to satisfy often competing objectives. For objectives expressed solely in terms of dose variances, deterministic gradient-based algorithms can be applied and a weighted sum approach is able to produce a representative set of non-dominated solutions. As the number of objectives increases, or non-convex objectives are used, local minima can be present and deterministic or stochastic algorithms such as simulated annealing either cannot be used or are not efficient. In this case we employ a modified hybrid version of the multi-objective optimization algorithm NSGA-II. This, in combination with the deterministic optimization algorithm, produces a representative sample of the Pareto set. This algorithm can be used with any kind of objectives, including non-convex, and does not require artificial importance factors. A representation of the trade-off surface can be obtained with more than 1000 non-dominated solutions in 2-5 min. An analysis of the solutions provides information on the possibilities available using these objectives. Simple decision making tools allow the selection of a solution that provides a best fit for the clinical goals. We show an example with a prostate implant and compare results obtained by variance and dose-volume histogram (DVH) based objectives

  16. Measuring the absorbed dose in critical organs during low rate dose brachytherapy with 137 Cs using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Torres, A.; Gonzalez, P.R.; Furetta, C.; Azorin, J.; Andres, U.; Mendez, G.

    2003-01-01

    Intracavitary Brachytherapy is one of the most used methods for the treatment of the cervical-uterine cancer. This treatment consists in the insertion of low rate dose 137 Cs sources into the patient. The most used system for the treatment dose planning is that of Manchester. This planning is based on sources, which are considered fixed during the treatment. However, the experience has shown that, during the treatment, the sources could be displaced from its initial position, changing the dose from that previously prescribed. For this reason, it is necessary to make measurements of the absorbed dose to the surrounding organs (mainly bladder and rectum). This paper presents the results of measuring the absorbed dose using home-made LiF: Mg, Cu, P + Ptfe thermoluminescent dosimeters (TLD). Measurements were carried out in-vivo during 20 minutes at the beginning and at the end of the treatments. Results showed that the absorbed dose to the critical organs vary significantly due to the movement of the patient during the treatment. (Author)

  17. Mechanical Design of the Radio-Isotope Source Driver Module for an Initial Prototype of Medium Dose Rate Brachytherapy

    International Nuclear Information System (INIS)

    Ari Satmoko; Tri Harjanto; Hendra Prasetia

    2012-01-01

    High dose rate brachytherapy equipment for therapy against cervical cancer is developed by empowering local products. An Iridium-192 with 5 Curies of energy is used. The source is wrapped in a capsule and combined with a wire diameter of 1 mm and length 1800 mm. The therapy is carried out by inserting the radiation source into the patient's body through an applicator. The system for loading-unloading the isotope source is divided into three modules: the source driver module, the source container modules, and channel distributor module. In this paper, the discussion is focused on engineering activities of the first module that serves to drive forward and backward position of the Iridium-192 isotope sources. The activity begins with the development of preliminary design sketches that produces drawings of mechanical components required. Furthermore, the calculations are carried out in order to establish the main component specifications. From this stage, a stepper motor type M66-A50K-G10 as a mechanical driver is chosen. The next stage is developing the detailed design and producing detailed drawings for all components. The fabrication of each component refers to the detailed design drawings. All components are assembled completely into the source driver module. Test also shows that the module works manually well. By rotating the manual handle in both directions, the tip of the wire moves alternately in forward and backward directions. (author)

  18. A tool to automatically analyze electromagnetic tracking data from high dose rate brachytherapy of breast cancer patients

    Science.gov (United States)

    Lahmer, G.; Strnad, V.; Bert, Ch.; Hensel, B.; Tomé, A. M.; Lang, E. W.

    2017-01-01

    During High Dose Rate Brachytherapy (HDR-BT) the spatial position of the radiation source inside catheters implanted into a female breast is determined via electromagnetic tracking (EMT). Dwell positions and dwell times of the radiation source are established, relative to the patient’s anatomy, from an initial X-ray-CT-image. During the irradiation treatment, catheter displacements can occur due to patient movements. The current study develops an automatic analysis tool of EMT data sets recorded with a solenoid sensor to assure concordance of the source movement with the treatment plan. The tool combines machine learning techniques such as multi-dimensional scaling (MDS), ensemble empirical mode decomposition (EEMD), singular spectrum analysis (SSA) and particle filter (PF) to precisely detect and quantify any mismatch between the treatment plan and actual EMT measurements. We demonstrate that movement artifacts as well as technical signal distortions can be removed automatically and reliably, resulting in artifact-free reconstructed signals. This is a prerequisite for a highly accurate determination of any deviations of dwell positions from the treatment plan. PMID:28934238

  19. Conventional external beam radiation therapy and high dose rate afterloading brachytherapy as a boost for patients older than 70 years

    International Nuclear Information System (INIS)

    Pellizzon, Antonio Cassio Assis; Salvajoli, Joao Vitor; Fogaroli, Ricardo Cesar; Novaes, Paulo Eduardo R.S.; Maia, Maria Aparecida Conte; Ferrigno, Robson

    2005-01-01

    The treatment options for patients with non metastatic prostate cancer range from observation, radical prostatectomy, radiation therapy, hormonal therapy to various combination of some to all of them. Objective: we evaluated the impact on biochemical control of disease (bNED), acute and late intestinal (GI) and urological (GU) morbidity for a group of patients older than 70 years presenting initial or locally advanced prostate cancer treated with fractionated high dose rate brachytherapy (HDRB) as a boost to conventional external beam radiation therapy (RT) at the Department of Radiation Oncology from Hospital do Cancer A. C. Camargo, Sao Paulo, Brazil. Methods: a total of 56 patients older than 70 were treated from March, 1997 to June, 2002. All patients had prior to HDRB a course of RT to a median dose of 45 Gy. HDRB doses ranged from 16 Gy to 20 Gy, given in 4 fractions. Results: the median age of the patients was 74.4 years (range 70-83) and the median follow-up 33 months (range 24 to 60). The 5-year actuarial bNED rate was 77%. Acute GU and GI morbidity G1-2 were seen in 17.8% and 7.1% of patients, respectively. Late G1 or G2 GU morbidity was seen in 10.7% of the patients, while late G3 morbidity was observed in 7.1% of the patients, represented by urethral strictures. Conclusion: this group of patients had similar bNED rates when compared to literature, with acceptable morbidity rates. (author)

  20. Intraoperative high-dose-rate brachytherapy for the treatment of pediatric tumors: the Ohio State University experience

    International Nuclear Information System (INIS)

    Nag, Subir; Tippin, Douglas; Ruymann, Frederick B.

    2001-01-01

    Purpose: To determine whether intraoperative high-dose-rate brachytherapy (IO-HDRBT) can be used to decrease the dose of external beam radiotherapy (EBRT) in the treatment of children with soft-tissue sarcomas and, thereby, reduce morbidity without compromising local control. Methods and Materials: From March 1992 through April 1999, 13 pediatric patients were treated with IO-HDRBT, low-dose EBRT, chemotherapy, and radical surgery at 21 sites that were not amenable to intraoperative electron beam therapy. The IO-HDRBT dose at 5 mm depth was 10 to 12.5 Gy for close margins/microscopic disease at 14 sites and 12.5 to 15 Gy for gross disease at 7 sites. The treatment volumes ranged from 4 to 96 cm 3 (mean 27). The EBRT dose was limited to 27-30 Gy in most cases to minimize growth retardation and preserve normal organ function. Results: After a median follow-up of 47 months (range 12-97), 11 patients were alive and without evidence of disease (overall survival rate 85%, 4-year actuarial survival rate 77%). Of the 2 who died, 1 had Stage III pulmonary blastoma with a sacral recurrence; the other had Stage IV undifferentiated synovial sarcoma with a pulmonary recurrence. One local failure occurred in a patient with gross residual disease after incomplete resection for Stage IV pulmonary blastoma. The local control rate was 95%, and morbidity was observed in 3 patients (23%). One patient developed impaired orbital growth with mild ptosis. Another patient required orthopedic pinning of her femoral subcapital epiphysis and construction of a neobladder secondary to urethral obstruction. The third patient required reimplantation of her autotransplanted kidney secondary to chronic urinary tract infection and ureteral reflux. Conclusions: IO-HDRBT allowed for reduction in EBRT without compromising local control or disease-free survival in children with soft-tissue sarcomas. Tumor beds inaccessible to electron beam methods could be satisfactorily encompassed with IO

  1. Favorable Preliminary Outcomes for Men With Low- and Intermediate-risk Prostate Cancer Treated With 19-Gy Single-fraction High-dose-rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Krauss, Daniel J., E-mail: dkrauss@beaumont.edu [Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States); Ye, Hong [Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States); Martinez, Alvaro A. [21st Century Oncology, Farmington Hills, Michigan (United States); Mitchell, Beth; Sebastian, Evelyn; Limbacher, Amy; Gustafson, Gary S. [Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States)

    2017-01-01

    Purpose: To report the toxicity and preliminary clinical outcomes of a prospective trial evaluating 19-Gy, single-fraction high-dose-rate (HDR) brachytherapy for men with low- and intermediate-risk prostate cancer. Methods and Materials: A total of 63 patients were treated according to an institutional review board-approved prospective study of single-fraction HDR brachytherapy. Eligible patients had tumor stage ≤T2a, prostate-specific antigen level ≤15 ng/mL, and Gleason score ≤7. Patients with a prostate gland volume >50 cm{sup 3} and baseline American Urologic Association symptom score >12 were ineligible. Patients underwent transrectal ultrasound-guided transperineal implantation of the prostate, followed by single-fraction HDR brachytherapy. Treatment was delivered using {sup 192}Ir to a dose of 19 Gy prescribed to the prostate, with no additional margin applied. Results: Of the 63 patients, 58 had data available for analysis. Five patients had withdrawn consent during the follow-up period. The median follow-up period was 2.9 years (range 0.3-5.2). The median age was 61.4 years. The median gland volume at treatment was 34.8 cm{sup 3}. Of the 58 patients, 91% had T1 disease, 71% had Gleason score ≤6 (29% with Gleason score 7), and the median pretreatment prostate-specific antigen level was 5.1 ng/mL. The acute and chronic grade 2 genitourinary toxicity incidence was 12.1% and 10.3%, respectively. No grade 3 urinary toxicity occurred. No patients experienced acute rectal toxicity grade ≥2, and 2 experienced grade ≥2 chronic gastrointestinal toxicity. Three patients experienced biochemical failure, yielding a 3-year cumulative incidence estimate of 6.8%. Conclusions: Single-fraction HDR brachytherapy is well-tolerated, with favorable preliminary biochemical and clinical disease control rates.

  2. Design and implementation of a film dosimetry audit tool for comparison of planned and delivered dose distributions in high dose rate (HDR) brachytherapy

    Science.gov (United States)

    Palmer, Antony L.; Lee, Chris; Ratcliffe, Ailsa J.; Bradley, David; Nisbet, Andrew

    2013-10-01

    A novel phantom is presented for ‘full system’ dosimetric audit comparing planned and delivered dose distributions in HDR gynaecological brachytherapy, using clinical treatment applicators. The brachytherapy applicator dosimetry test object consists of a near full-scatter water tank with applicator and film supports constructed of Solid Water, accommodating any typical cervix applicator. Film dosimeters are precisely held in four orthogonal planes bisecting the intrauterine tube, sampling dose distributions in the high risk clinical target volume, points A and B, bladder, rectum and sigmoid. The applicator position is fixed prior to CT scanning and through treatment planning and irradiation. The CT data is acquired with the applicator in a near clinical orientation to include applicator reconstruction in the system test. Gamma analysis is used to compare treatment planning system exported RTDose grid with measured multi-channel film dose maps. Results from two pilot audits are presented, using Ir-192 and Co-60 HDR sources, with a mean gamma passing rate of 98.6% using criteria of 3% local normalization and 3 mm distance to agreement (DTA). The mean DTA between prescribed dose and measured film dose at point A was 1.2 mm. The phantom was funded by IPEM and will be used for a UK national brachytherapy dosimetry audit.

  3. SU-G-201-01: An Automated Treatment Plan Quality Assurance Program for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Y; Tan, J; Jiang, S; Albuquerque, K; Jia, X [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: Plan specific quality assurance (QA) is an important step in high dose rate (HDR) brachytherapy to ensure the integrity of a treatment plan. The conventional approach is to assemble a set of plan screen-captures in a document and have an independent plan-checker to verify it. Not only is this approach cumbersome and time-consuming, using a document also limits the items that can be verified, hindering plan quality and patient safety. We have initiated efforts to develop a web-based HDR brachytherapy QA system called AutoBrachy QA, for comprehensive and efficient QA. This abstract reports a new plugin in this system for the QA of a cylinder HDR brachytherapy treatment. Methods: A cylinder plan QA module was developed using Python. It was plugged into our AutoBrachy QA system. This module extracted information from CT images and treatment plan. Image processing techniques were employed to obtain geometric parameters, e.g. cylinder diameter. A comprehensive set of eight geometrical and eight dosimetric features of the plan were validated against user specified planning parameter, such as prescription value, treatment depth and length, etc. A PDF document was generated, consisting of a summary QA sheet with all the QA results, as well as images showing plan details. Results: The cylinder QA program has been implemented in our clinic. To date, it has been used in 11 patient cases and was able to successfully perform QA tests in all of them. The QA program reduced the average plan QA time from 7 min using conventional manual approach to 0.5 min. Conclusion: Being a new module in our AutoBrachy QA system, an automated treatment plan QA module for cylinder HDR brachytherapy has been successfully developed and clinically implemented. This module improved clinical workflow and plan integrity compared to the conventional manual approach.

  4. Dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with high-dose-rate brachytherapy for large prostate volumes

    Energy Technology Data Exchange (ETDEWEB)

    Yang, George; Strom, Tobin J.; Shrinath, Kushagra; Mellon, Eric A.; Fernandez, Daniel C.; Biagioli, Matthew C. [Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States); Wilder, Richard B., E-mail: mcbiagioli@yahoo.com [Cancer Treatment Centers of America, Newnan, GA (United States)

    2015-05-15

    Purpose: to evaluate dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with HDR brachytherapy for large prostate volumes. Materials and methods: one hundred and two prostate cancer patients with prostate volumes >50 mL (range: 5-29 mL) were treated with high-dose-rate (HDR) brachytherapy ± intensity modulated radiation therapy (IMRT) to 4,500 cGy in 25 daily fractions between 2009 and 2013. HDR brachytherapy monotherapy doses consisted of two 1,350-1,400 cGy fractions separated by 2-3 weeks, and HDR brachytherapy boost doses consisted of two 950-1,150 cGy fractions separated by 4 weeks. Twelve of 32 (38%) unfavorable intermediate risk, high risk, and very high risk patients received androgen deprivation therapy. Acute toxicity was graded according to the Common Terminology Criteria for Adverse Events (CTCAE) version 4. Results: median follow-up was 14 months. Dosimetric goals were achieved in over 90% of cases. Three of 102 (3%) patients developed Grade 2 acute proctitis. No variables were significantly associated with Grade 2 acute proctitis. Seventeen of 102 (17%) patients developed Grade 2 acute urinary retention. American Urological Association (AUA) symptom score was the only variable significantly associated with Grade 2 acute urinary retention (p-0.04). There was no ≥ Grade 3 acute toxicity. Conclusions: dosimetric coverage of the prostate and normal tissue sparing were adequate in patients with prostate volumes >50 mL. Higher pre-treatment AUA symptom scores increased the relative risk of Grade 2 acute urinary retention. However, the overall incidence of acute toxicity was acceptable in patients with large prostate volumes. (author)

  5. Dosimetric Coverage of the Prostate, Normal Tissue Sparing, and Acute Toxicity with High-Dose-Rate Brachytherapy for Large Prostate Volumes

    Directory of Open Access Journals (Sweden)

    George Yang

    2015-06-01

    Full Text Available ABSTRACTPurposeTo evaluate dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with HDR brachytherapy for large prostate volumes.Materials and MethodsOne hundred and two prostate cancer patients with prostate volumes >50 mL (range: 5-29 mL were treated with high-dose-rate (HDR brachytherapy ± intensity modulated radiation therapy (IMRT to 4,500 cGy in 25 daily fractions between 2009 and 2013. HDR brachytherapy monotherapy doses consisted of two 1,350-1,400 cGy fractions separated by 2-3 weeks, and HDR brachytherapy boost doses consisted of two 950-1,150 cGy fractions separated by 4 weeks. Twelve of 32 (38% unfavorable intermediate risk, high risk, and very high risk patients received androgen deprivation therapy. Acute toxicity was graded according to the Common Terminology Criteria for Adverse Events (CTCAE version 4.ResultsMedian follow-up was 14 months. Dosimetric goals were achieved in over 90% of cases. Three of 102 (3% patients developed Grade 2 acute proctitis. No variables were significantly associated with Grade 2 acute proctitis. Seventeen of 102 (17% patients developed Grade 2 acute urinary retention. American Urological Association (AUA symptom score was the only variable significantly associated with Grade 2 acute urinary retention (p=0.04. There was no ≥ Grade 3 acute toxicity.ConclusionsDosimetric coverage of the prostate and normal tissue sparing were adequate in patients with prostate volumes >50 mL. Higher pre-treatment AUA symptom scores increased the relative risk of Grade 2 acute urinary retention. However, the overall incidence of acute toxicity was acceptable in patients with large prostate volumes.

  6. Accuracy of applicator tip reconstruction in MRI-guided interstitial 192Ir-high-dose-rate brachytherapy of liver tumors

    International Nuclear Information System (INIS)

    Wybranski, Christian; Eberhardt, Benjamin; Fischbach, Katharina; Fischbach, Frank; Walke, Mathias; Hass, Peter; Röhl, Friedrich-Wilhelm; Kosiek, Ortrud; Kaiser, Mandy; Pech, Maciej; Lüdemann, Lutz; Ricke, Jens

    2015-01-01

    Background and purpose: To evaluate the reconstruction accuracy of brachytherapy (BT) applicators tips in vitro and in vivo in MRI-guided 192 Ir-high-dose-rate (HDR)-BT of inoperable liver tumors. Materials and methods: Reconstruction accuracy of plastic BT applicators, visualized by nitinol inserts, was assessed in MRI phantom measurements and in MRI 192 Ir-HDR-BT treatment planning datasets of 45 patients employing CT co-registration and vector decomposition. Conspicuity, short-term dislocation, and reconstruction errors were assessed in the clinical data. The clinical effect of applicator reconstruction accuracy was determined in follow-up MRI data. Results: Applicator reconstruction accuracy was 1.6 ± 0.5 mm in the phantom measurements. In the clinical MRI datasets applicator conspicuity was rated good/optimal in ⩾72% of cases. 16/129 applicators showed not time dependent deviation in between MRI/CT acquisition (p > 0.1). Reconstruction accuracy was 5.5 ± 2.8 mm, and the average image co-registration error was 3.1 ± 0.9 mm. Vector decomposition revealed no preferred direction of reconstruction errors. In the follow-up data deviation of planned dose distribution and irradiation effect was 6.9 ± 3.3 mm matching the mean co-registration error (6.5 ± 2.5 mm; p > 0.1). Conclusion: Applicator reconstruction accuracy in vitro conforms to AAPM TG 56 standard. Nitinol-inserts are feasible for applicator visualization and yield good conspicuity in MRI treatment planning data. No preferred direction of reconstruction errors were found in vivo

  7. Toxicity and cosmetic result of partial breast high-dose-rate interstitial brachytherapy for conservatively operated early breast cancer

    International Nuclear Information System (INIS)

    Xiu Xia; Tripuraneni Prabhakar; Giap Huan; Lin Ray; Chu Colin

    2007-01-01

    Objective: Objective To study the method, side effects and cosmetic outcome of high- dose-rate (HDR) accelerated partial breast interstitial irradiation (APBI) alone in early stage breast cancer' after conservative surgery. Methods: From February 2002 to June 2003,47 breast cancer lesions from 46 patients suffering from stage I/II breast cancer were treated with HDR 192 Ir APBI after conservative surgery. All patients were over 40 year-old, with T1-2N0-1 (≤3 lymph nodes positive), surgical margin > 1-2 mm, but those having lobular or inflammatory breast cancer were excluded. HDR brachytherapy with 34 Gy, 10 fractions/5 days was used after surgery, toxic reaction and cosmetic outcome were observed in one month, 6 and 12 months respectively. Results: Follow up of 1846 months, 34 months was carried out for the whole group. During the treatment, acute reactions including: erythema, edema, tenderness and infection, all under I-II grade, none of III-IV grade were observed in 21 patients(46%); late toxicity reactions: skin fibrosis, breast tenderness, fat necrosis, and telangiectasia, totally 20 patients (43%) were observed: 2 patients in III grade but one patient received 6 cycle chemotherapy. The result of cosmetic outcome evaluation was excellent or good, at 6 months 95% and 12 months 98%, respectively, but there was no recurfence. Conclusions: Excellent and favorable cosmetic results are noted after APBI by interstitial alone. Acute and late reactions are few. Long term observation is necessary for the rate of' local control. (authors)

  8. A generalized linear-quadratic model for radiosurgery, stereotactic body radiation therapy, and high-dose rate brachytherapy.

    Science.gov (United States)

    Wang, Jian Z; Huang, Zhibin; Lo, Simon S; Yuh, William T C; Mayr, Nina A

    2010-07-07

    Conventional radiation therapy for cancer usually consists of multiple treatments (called fractions) with low doses of radiation. These dose schemes are planned with the guidance of the linear-quadratic (LQ) model, which has been the most prevalent model for designing dose schemes in radiation therapy. The high-dose fractions used in newer advanced radiosurgery, stereotactic radiation therapy, and high-dose rate brachytherapy techniques, however, cannot be accurately calculated with the traditional LQ model. To address this problem, we developed a generalized LQ (gLQ) model that encompasses the entire range of possible dose delivery patterns and derived formulas for special radiotherapy schemes. We show that the gLQ model can naturally derive the traditional LQ model for low-dose and low-dose rate irradiation and the target model for high-dose irradiation as two special cases of gLQ. LQ and gLQ models were compared with published data obtained in vitro from Chinese hamster ovary cells across a wide dose range [0 to approximately 11.5 gray (Gy)] and from animals with dose fractions up to 13.5 Gy. The gLQ model provided consistent interpretation across the full dose range, whereas the LQ model generated parameters that depended on dose range, fitted only data with doses of 3.25 Gy or less, and failed to predict high-dose responses. Therefore, the gLQ model is useful for analyzing experimental radiation response data across wide dose ranges and translating common low-dose clinical experience into high-dose radiotherapy schemes for advanced radiation treatments.

  9. Estimation of the optimal brachytherapy utilisation rate in the treatment of vaginal cancer and comparison with patterns of care

    International Nuclear Information System (INIS)

    Thompson, Stephen R.; Delaney, Geoff P.; Gabriel, Gabriel S.; Barton, Michael B.; Jacob, Susannah

    2012-01-01

    Having previously modelled the optimal proportion of uterine cervix and corpus cancers that should be treated with brachytherapy (BT), we aimed to complete the assessment of the role of BT for gynaecological cancers by estimating the optimal proportion of vaginal cancer cases that should be treated with BT, the optimal BT utilisation (BTU) rate for vaginal cancer. We compared this with actual vaginal BTU and assessed quality of BT for vaginal cancer by a Patterns-of-Care Study (POCS). Evidence-based guidelines were used to construct an optimal BTU decision tree for vaginal cancer. Searches of the epidemiological literature to ascertain the proportion of patients who fulfilled the criteria for BT were conducted. The robustness of the model was tested by sensitivity analyses and by peer review. A retrospective POCS of BT in New South Wales (NSW) for 2003 was conducted, and actual BTU for vaginal cancer was determined. Differences between optimal and actual BTU were assessed. Quality of BT for vaginal cancer was compared with published benchmarks. The optimal vaginal cancer BTU rate was estimated to be 85% (range 81–87%). In NSW in 2003, actual vaginal cancer BTU was only 42% (95% confidence interval 22–62%). In NSW, only nine patients were treated, all with intra-vaginal cylinders, and two of four to lower than recommended doses. BT for vaginal cancers is under utilised in NSW compared with the proposed optimal models of care. BT quality may have been suboptimal and this may relate to the rarity of this disease.

  10. Image-Guided High-Dose Rate Brachytherapy in Cervix Carcinoma Using Balloon Catheter and Belt Immobilization System.

    Science.gov (United States)

    Fan, Qiyong; Yeung, Anamaria R; Amdur, Robert; Helmig, Richard; Park, Justin; Li, Jonathan; Kahler, Darren; Liu, Chihray; Lu, Bo

    2017-06-01

    The efficacy of image-guided high-dose rate brachytherapy for cervical cancer is limited by the ineffective rectal sparing devices available commercially and the potential applicator movement. We developed a novel device using a balloon catheter and a belt immobilization system, serving for rectal dose reduction and applicator immobilization purposes, respectively. The balloon catheter is constructed by gluing a short inflatable tube to a long regular open-end catheter. Contrast agent (10) cm 3 is injected into the inflatable end, which is affixed to the tandem and ring applicator, to displace the posterior vaginal wall. The belt immobilization system consists of a specially designed bracket that can hold and fix itself to the applicator, a diaper-like Velcro fastener package used for connecting the patient's pelvis to the bracket, and a buckle that holds the fasteners to stabilize the whole system. The treatment data for 21 patients with cervical cancer using both balloon catheter and belt immobilization system were retrospectively analyzed. Computed tomography and magnetic resonance images, acquired about 30 minutes apart, were registered to evaluate the effectiveness of the immobilization system. In comparison with a virtual rectal blade, the balloon decreased the rectal point dose by 34% ± 4.2% (from 276 ± 57 to 182 ± 38 cGy), corresponding to an extra sparing distance of 7.9 ± 1.1 mm. The maximum sparing distance variation per patient is 1.4 ± 0.6 mm, indicating the high interfractional reproducibility for rectum sparing. With the immobilization system, the mean translational and rotational displacements of the applicator set are <3 mm and <1.5°, respectively, in all directions. The rectal balloon provides significant dose reduction to the rectum and it may potentially minimize patient discomfort. The immobilization system permits almost no movement of the applicator during treatment. This work has the potential to be promoted as a standardized solution

  11. Chemoradiation in cervical cancer with cisplatin and high-dose rate brachytherapy combined with external beam radiotherapy. Results of a phase-II study

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, H.G.; Laban, C.; Puschmann, D.; Koelbl, H. [Dept. of Gynecology, Martin-Luther Univ. Halle-Wittenberg (Germany); Kuhnt, T.; Pigorsch, S.; Dunst, J.; Haensgen, G. [Dept. of Radiotherapy, Martin-Luther Univ. Halle-Wittenberg (Germany)

    2002-07-01

    Background: In 1999, five randomized studies demonstrated that chemoradiation with cisplatin and low-dose rate (LDR) brachytherapy has a benefit in locally advanced cervical cancer and for surgically treated patients in high-risk situations. We evaluated the safety and efficacy of concomitant chemoradiation with cisplatin and high-dose rate (HDR) brachytherapy in patients with cervical cancer. Patients and Method: 27 patients were included in our phase-II trial: 13 locally advanced cases (group A) and 14 adjuvant-therapy patients in high-risk situations (group B). A definitive radiotherapy was performed with 25 fractions of external beam therapy (1.8 Gy per fraction/middle shielded after eleven fractions). Brachytherapy was delivered at HDR schedules with 7 Gy in point A per fraction (total dose 35 Gy) in FIGO Stages IIB-IIIB. The total dose of external and brachytherapy was 70 Gy in point A and 52-54 Gy in point B. All patients in stage IVA were treated without brachytherapy. Adjuvant radiotherapy was performed with external beam radiotherapy of the pelvis with 1.8 Gy single-dose up to 50.4 Gy. Brachytherapy was delivered at HDR schedules with two fractions of 5 Gy only in patients with tumor-positive margins or tumor involvement of the upper vagina. The chemotherapeutic treatment schedule provided six courses of cisplatin 40 mg/m{sup 2} weekly recommended in the randomized studies GOG-120 and -123. Results: A total of 18/27 patients (66.7%) completed all six courses of chemotherapy. Discontinuation of radiotherapy due to therapy-related morbidity was not necessary in the whole study group. G3 leukopenia (29.6%) was the only relevant acute toxicity. There were no differences in toxicity between group A and B. Serious late morbidity occurred in 2/27 patients (7.4%). 12/13 patients (92.3%) with IIB-IVA cervical cancer showed a complete response (CR). 13/14 adjuvant cases (92.8%) are free of recurrence (median follow up: 19.1 months). Conclusion: Concomitant

  12. Analysis of complications in a prospective randomized trial comparing two brachytherapy low dose rates in cervical carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-07-30

    The analysis of complications in a prospective randomized trial comparing two preoperative brachytherapy low-dose rates in early stage cervical cancer is presented. The objective of this trial was to determine the benefits, if any, of the higher-dose rate within the therapeutic aresenal for this patient population, in terms of survival, local control, and complications. Overall survival, 85% at 2 years and local control, 93% at 2 years, were similarly distributed between the two groups. Regardless of their nature and severity, 139 and 175 complications were observed among 63% and 75% of patients, in the 0.4 and 0.8 Gy/h dose rate groups respectively. Gynecologic and urinary complications were the most frequent (38% and 28% of all complications), followed by vascular (15%), digestive (10%), nervous (5%), and cutaneous (5%). A total of 14 and 17 severe complications (Grade 3) were observed in 7% and 13% of patients, respectively in the 0.4 and 0.8 Gy/h dose rate groups (p = 0.12) Nonparametric survival methods used to compare the time to the first complication did not show a significant difference between the two groups: 62% and 72% at 2 years (p = 0.27). When the first complication and its evolution were considered (early complications), the prevalence of complications was not significantly different between the two groups: 28% vs. 34% at 2 years (p = 0.31). In this prospective trial, patients were regularly followed-up and complications of varying nature and severity were observed in succession during follow-up. When successive complications and their evolution were taken into account, the prevalence of complications was significantly greater in the higher-dose rate group: 30% vs 45% at 2 years (p = 0.03). The results of this trial showed that long-term effects of treatment, when represented by prevalence of complications over time, were more frequent in the higher dose rate group. 33 refs., 3 figs., 5 tabs.

  13. High-Dose-Rate Brachytherapy Boost Effect on Local Tumor Control in Young Women With Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Guinot, Jose-Luis, E-mail: jguinot@fivo.org [Department of Radiation Oncology, Fundacion Instituto Valenciano de Oncologia, Valencia (Spain); Baixauli-Perez, Cristobal [Health Services Research Unit, Center for Public Health Research, Valencia (Spain); Soler, Pablo; Tortajada, Maria Isabel; Moreno, Araceli; Santos, Miguel Angel; Mut, Alejandro [Department of Radiation Oncology, Fundacion Instituto Valenciano de Oncologia, Valencia (Spain); Gozalbo, Francisco [Department of Pathology, Fundacion Instituto Valenciano de Oncologia, Valencia (Spain); Arribas, Leoncio [Department of Radiation Oncology, Fundacion Instituto Valenciano de Oncologia, Valencia (Spain)

    2015-01-01

    Purpose: To evaluate the local control rate and complications of a single fraction of high-dose-rate brachytherapy (HDR BT) boost in women aged 45 yeas and younger after breast-conserving therapy. Methods and Materials: Between 1999 and 2007, 167 patients between the ages of 26 and 45 years old (72 were 40 years old or younger), with stages T1 to T2 invasive breast cancer with disease-free margin status of at least 5 mm after breast-conserving surgery received 46 to 50 Gy whole-breast irradiation plus a 7-Gy HDR-BT boost (“fast boost”). An axillary dissection was performed in 72.5% of the patients and sentinel lymph node biopsy in 27.5%. A supraclavicular area was irradiated in 19% of the patients. Chemotherapy was used in 86% of the patients and hormone treatment in 77%. Clinical nodes were present in 18% and pathological nodes in 29%. The pathological stage was pT0: 5%, pTis: 3%, pT1: 69% and pT2: 23%. Intraductal component was present in 40% and 28% were G3. Results: At a median follow-up of 92 months, 9 patients relapsed on the margin of the implant, and 1 patient in another quadrant, resulting in a 10-year local relapse rate of 4.3% and a breast relapse rate of 4.9%, with breast preservation in 93.4%; no case of mastectomy due to poor cosmesis arose. Actuarial 5- and 10-year disease-free, cause-specific, and overall survival rates were 87.9% and 85.8%, and 92.1% and 88.4%, and 92.1% and 87.3%, respectively. In a univariate analysis, triple-negative cases and negative hormone receptors did worse, but in a multivariate analysis, only the last factor was significant for local and breast control. Asymptomatic fibrosis G2 was recorded in 3 cases, and there were no other late complications. Cosmetic results were good to excellent in 97% of cases. Conclusions: A single dose of 7 Gy using the fast-boost technique is well tolerated, with a low rate of late complications and improved local tumor control in women aged 45 and younger, compared to published data

  14. Prostate-Specific Antigen at 4 to 5 Years After Low-Dose-Rate Prostate Brachytherapy Is a Strong Predictor of Disease-Free Survival

    Energy Technology Data Exchange (ETDEWEB)

    Lo, Andrea C. [Department of Radiation Oncology, British Columbia Cancer Agency Vancouver Centre, Vancouver, British Columbia (Canada); Department of Surgery, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia (Canada); Morris, W. James, E-mail: JMorris@bccancer.bc.ca [Department of Radiation Oncology, British Columbia Cancer Agency Vancouver Centre, Vancouver, British Columbia (Canada); Department of Surgery, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia (Canada); Lapointe, Vincent [Department of Medical Physics, British Columbia Cancer Agency Vancouver Centre, Vancouver, British Columbia (Canada); Hamm, Jeremy [Department of Population Oncology, British Columbia Cancer Agency Vancouver Centre, Vancouver, British Columbia (Canada); Keyes, Mira; Pickles, Tom; McKenzie, Michael [Department of Radiation Oncology, British Columbia Cancer Agency Vancouver Centre, Vancouver, British Columbia (Canada); Department of Surgery, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia (Canada); Spadinger, Ingrid [Department of Surgery, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia (Canada); Department of Medical Physics, British Columbia Cancer Agency Vancouver Centre, Vancouver, British Columbia (Canada)

    2014-01-01

    Purpose: To determine (1) the prognostic utility of prostate-specific antigen (PSA) concentration at 45 to 60 months (48mPSA) after low-dose-rate prostate brachytherapy (LDR-PB); (2) the predictors of 48mPSA; and (3) the prognostic utility of directional trends between PSA levels at 24, 36, and 48 months after LDR-PB. Methods and Materials: Between 1998 and 2008, 2223 patients with low- and intermediate-risk prostate cancer received LDR-PB monotherapy. A cohort of 1434 of these patients was identified with a documented 48mPSA and no evidence of disease relapse prior to the 48mPSA. In addition, a subset of this cohort (n=585) was identified with ≥72 months of follow-up and documented PSA values at both 24 and 36 months after implantation. Results: Median follow-up time was 76 months. Eight-year Kaplan-Meier disease-free survival (DFS) rates were 100% vs 73.4% for patients with 48mPSA ≤0.2 vs those with >0.2 ng/mL; 99.1% versus 53.8% for a 48mPSA threshold of ≤0.4 versus >0.4 ng/mL, respectively; and 97.3% versus 0% for a threshold of ≤1.0 versus >1.0 ng/mL, respectively. On multivariate analysis, the only factor predictive of DFS was 48mPSA (P<.0001). On subset analysis (n=585), 29 patients had a PSA rise (defined as >0.2 ng/mL) between 24 and 36 months, 24 patients had a rise between 36 and 48 months, and 11 patients had rises over both intervals. Failure rates in these patients were 52%, 79%, and 100%, respectively. On multivariate analysis, initial PSA, androgen deprivation therapy, and dose to 90% of the prostate significantly correlated with 48mPSA but together accounted for only ∼5% of its total variance. Conclusions: The 48mPSA after LDR-PB is highly predictive of long-term DFS. Patients with 48mPSA ≤0.4 ng/mL had a <1% risk of disease relapse at 8 years, whereas all patients with 48mPSA >1.0 ng/mL relapsed. Consecutive PSA rises of >0.2 ng/mL from 24 to 36 months and from 36 to 48 months were also highly predictive of subsequent failure.

  15. Polyethylene glycol hydrogel rectal spacer implantation in patients with prostate cancer undergoing combination high-dose-rate brachytherapy and external beam radiotherapy.

    Science.gov (United States)

    Yeh, Jekwon; Lehrich, Brandon; Tran, Carolyn; Mesa, Albert; Baghdassarian, Ruben; Yoshida, Jeffrey; Torrey, Robert; Gazzaniga, Michael; Weinberg, Alan; Chalfin, Stuart; Ravera, John; Tokita, Kenneth

    2016-01-01

    To present rectal toxicity rates in patients administered a polyethylene glycol (PEG) hydrogel rectal spacer in conjunction with combination high-dose-rate brachytherapy and external beam radiotherapy. Between February 2010 and April 2015, 326 prostate carcinoma patients underwent combination high-dose-rate brachytherapy of 16 Gy (average dose 15.5 Gy; standard deviation [SD] = 1.6 Gy) and external beam radiotherapy of 59.4 Gy (average dose 60.2 Gy; SD = 2.9 Gy). In conjunction with the radiation therapy regimen, each patient was injected with 10 mL of a PEG hydrogel in the anterior perirectal fat space. The injectable spacer (rectal spacer) creates a gap between the prostate and the rectum. The rectum is displaced from the radiation field, and rectal dose is substantially reduced. The goal is a reduction in rectal radiation toxicity. Clinical efficacy was determined by measuring acute and chronic rectal toxicity using the National Cancer Center Institute Common Terminology Criteria for Adverse Events v4.0 grading scheme. Median followup was 16 months. The mean anterior-posterior separation achieved was 1.6 cm (SD = 0.4 cm). Rates of acute Grade 1 and 2 rectal toxicity were 37.4% and 2.8%, respectively. There were no acute Grade 3/4 toxicities. Rates of late Grade 1, 2, and 3 rectal toxicity were 12.7%, 1.4%, and 0.7%, respectively. There were no late Grade 4 toxicities. PEG rectal spacer implantation is safe and well tolerated. Acute and chronic rectal toxicities are low despite aggressive dose escalation. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  16. Conventional High-Dose-Rate Brachytherapy With Concomitant Complementary IMRT Boost: A Novel Approach for Improving Cervical Tumor Dose Coverage

    International Nuclear Information System (INIS)

    Duan, Jun; Kim, Robert Y.; Elassal, Shaaban; Lin Huiyi; Shen Sui

    2008-01-01

    Purpose: To investigate the feasibility of combining conventional high-dose-rate (HDR) brachytherapy with a concomitant complementary intensity-modulated radiotherapy (IMRT) boost for improved target coverage in cervical cancers. Methods and Materials: Six patients with cervical cancer underwent conventional HDR (C-HDR) treatment. Computed tomography (CT) and magnetic resonance imaging (MRI) scans were acquired with a CT/MRI-compatible applicator in place. The clinical target volumes (CTVs), defined as the gross target volume with a 3-mm margin and the uterus, were delineated on the CT scans, along with the organs at risk (OARs). The IMRT plans were optimized to generate dose distributions complementing those of C-HDR to cover the CTV while maintaining low doses to the OARs (IMRT-HDR). For comparison, dwell-weight optimized HDR (O-HDR) plans were also generated to cover the CTV and spare the OARs. The three treatment techniques (C-HDR, O-HDR, and IMRT-HDR) were compared. The percentage of volume receiving 95% of the prescription dose (V 95 ) was used to evaluate dose coverage to the CTV, and the minimal doses in the 2.0-cm 3 volume receiving the greatest dose were calculated to compare the doses to the OARs. Results: The C-HDR technique provided very poor CTV coverage in 5 cases (V 95 95 ≥96.9%), it resulted in unacceptably high doses to the OARs in all 6 cases and unsatisfactory coverage to the whole CTV in 3 cases. IMRT-HDR not only yielded substantially improved CTV coverage (average V 95 = 95.3%), but also kept the doses to the bladder and rectum reasonably low. Conclusion: Compared with C-HDR and O-HDR, concomitant IMRT boost complementary to C-HDR not only provided excellent CTV coverage, but also maintained reasonably low doses to the OARs

  17. Dosimetric comparison between a planning system and Radiochromic-EBT2 films in surface brachytherapy treatments of high rate

    International Nuclear Information System (INIS)

    Gutierrez Ramos, S. M.; Carrasco Herrera, M. a.; Vicent, D.; Rodriguez, C.; Herrador, M.

    2013-01-01

    The objective of this work is to study a situation in which, the accuracy of the calculation of the planner may be limited, superficial brachytherapy treatment. It has relative to the dose obtained with the planner with that obtained with film radiochromic EBT2. (Author)

  18. High-Dose-Rate Brachytherapy for the Treatment of Recalcitrant Keloids: A Unique, Effective Treatment Protocol

    NARCIS (Netherlands)

    van Leeuwen, M.C.E.; Stokmans, S.C.; Bulstra, A.E.J.; Meijer, O.W.M.; van Leeuwen, P.A.M.; Niessen, F.B.

    2014-01-01

    BACKGROUND:: Keloids cause aesthetic disfigurement and physical complaints, mainly pain and pruritus. Treatment of these scars is difficult, with high recurrence rates forming the main issue. Surgical excision with adjuvant radiotherapy is considered the most efficacious treatment. At their

  19. Effect of rectal enemas on rectal dosimetric parameters during high-dose-rate vaginal cuff brachytherapy. A prospective trial

    Energy Technology Data Exchange (ETDEWEB)

    Sabater, Sebastia; Andres, Ignacio; Sevillano, Marimar; Berenguer, Roberto; Aguayo, Manuel; Villas, Maria Victoria [Complejo Hospitalario Universitario de Albacete (CHUA), Department of Radiation Oncology, Albacete (Spain); Gascon, Marina; Arenas, Meritxell [Hospital Universitari Sant Joan, Department of Radiation Oncology, Reus (Spain); Rovirosa, Angeles; Camacho-Lopez, Cristina [University of Barcelona, IDIBAPS, Gynecological Cancer Unit, Radiation Oncology Department, ICMHO, Hospital Clinic, Barcelona (Spain)

    2016-04-15

    To evaluate the effects of rectal enemas on rectal doses during postoperative high-dose-rate (HDR) vaginal cuff brachytherapy (VCB). This prospective trial included 59 patients. Two rectal cleansing enemas were self-administered before the second fraction, and fraction 1 was considered the basal status. Dose-volume histogram (DVH) values were generated for the rectum and correlated with rectal volume variation. Statistical analyses used paired and unpaired t-tests. Despite a significant 15 % reduction in mean rectal volume (44.07 vs. 52.15 cc, p = 0.0018), 35.6 % of patients had larger rectums after rectal enemas. No significant rectal enema-related DVH differences were observed compared to the basal data. Although not statistically significant, rectal cleansing-associated increases in mean rectal DVH values were observed: D{sub 0.1} {sub cc}: 6.6 vs. 7.21 Gy; D{sub 1} {sub cc}: 5.35 vs. 5.52 Gy; D{sub 2} {sub cc}: 4.67 vs. 4.72 Gy, before and after rectal cleaning, respectively (where D{sub x} {sub cc} is the dose to the most exposed x cm {sup 3}). No differences were observed in DVH parameters according to rectal volume increase or decrease after the enema. Patients whose rectal volume increased also had significantly larger DVH parameters, except for D{sub 5} {sub %}, D{sub 25} {sub %}, and D{sub 50} {sub %}. In contrast, in patients whose rectal volume decreased, significance was only seen for D{sub 25} {sub %} and D{sub 50} {sub %} (D{sub x} {sub %} dose covering x % of the volume). In the latter patients, nonsignificant reductions in D{sub 2} {sub cc}, D{sub 5} {sub cc} and V{sub 5} {sub Gy} (volume receiving at least 5 Gy) were observed. The current rectal enemas protocol was ineffective in significantly modifying rectal DVH parameters for HDR-VCB. (orig.) [German] Beurteilung der Auswirkungen von rektalen Dosen waehrend postoperativer High-Dose-Rate-(HDR-)Brachytherapie an der Scheidenmanschette (''vaginal cuff brachytherapy'', VCB). An

  20. The evaluation of a 2D diode array in “magic phantom” for use in high dose rate brachytherapy pretreatment quality assurance

    International Nuclear Information System (INIS)

    Espinoza, A.; Petasecca, M.; Fuduli, I.; Lerch, M. L. F.; Rosenfeld, A. B.; Howie, A.; Bucci, J.; Corde, S.; Jackson, M.

    2015-01-01

    Purpose: High dose rate (HDR) brachytherapy is a treatment method that is used increasingly worldwide. The development of a sound quality assurance program for the verification of treatment deliveries can be challenging due to the high source activity utilized and the need for precise measurements of dwell positions and times. This paper describes the application of a novel phantom, based on a 2D 11 × 11 diode array detection system, named “magic phantom” (MPh), to accurately measure plan dwell positions and times, compare them directly to the treatment plan, determine errors in treatment delivery, and calculate absorbed dose. Methods: The magic phantom system was CT scanned and a 20 catheter plan was generated to simulate a nonspecific treatment scenario. This plan was delivered to the MPh and, using a custom developed software suite, the dwell positions and times were measured and compared to the plan. The original plan was also modified, with changes not disclosed to the primary authors, and measured again using the device and software to determine the modifications. A new metric, the “position–time gamma index,” was developed to quantify the quality of a treatment delivery when compared to the treatment plan. The MPh was evaluated to determine the minimum measurable dwell time and step size. The incorporation of the TG-43U1 formalism directly into the software allows for dose calculations to be made based on the measured plan. The estimated dose distributions calculated by the software were compared to the treatment plan and to calibrated EBT3 film, using the 2D gamma analysis method. Results: For the original plan, the magic phantom system was capable of measuring all dwell points and dwell times and the majority were found to be within 0.93 mm and 0.25 s, respectively, from the plan. By measuring the altered plan and comparing it to the unmodified treatment plan, the use of the position–time gamma index showed that all modifications made could be

  1. The evaluation of a 2D diode array in “magic phantom” for use in high dose rate brachytherapy pretreatment quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Espinoza, A.; Petasecca, M.; Fuduli, I.; Lerch, M. L. F.; Rosenfeld, A. B., E-mail: anatoly@uow.edu.au [Centre for Medical Radiation Physics, University of Wollongong, New South Wales 2522 (Australia); Howie, A.; Bucci, J. [St George Hospital Cancer Care Centre, New South Wales 2217 (Australia); Corde, S.; Jackson, M. [Department of Radiation Oncology, Prince of Wales Hospital, New South Wales 2031 (Australia)

    2015-02-15

    Purpose: High dose rate (HDR) brachytherapy is a treatment method that is used increasingly worldwide. The development of a sound quality assurance program for the verification of treatment deliveries can be challenging due to the high source activity utilized and the need for precise measurements of dwell positions and times. This paper describes the application of a novel phantom, based on a 2D 11 × 11 diode array detection system, named “magic phantom” (MPh), to accurately measure plan dwell positions and times, compare them directly to the treatment plan, determine errors in treatment delivery, and calculate absorbed dose. Methods: The magic phantom system was CT scanned and a 20 catheter plan was generated to simulate a nonspecific treatment scenario. This plan was delivered to the MPh and, using a custom developed software suite, the dwell positions and times were measured and compared to the plan. The original plan was also modified, with changes not disclosed to the primary authors, and measured again using the device and software to determine the modifications. A new metric, the “position–time gamma index,” was developed to quantify the quality of a treatment delivery when compared to the treatment plan. The MPh was evaluated to determine the minimum measurable dwell time and step size. The incorporation of the TG-43U1 formalism directly into the software allows for dose calculations to be made based on the measured plan. The estimated dose distributions calculated by the software were compared to the treatment plan and to calibrated EBT3 film, using the 2D gamma analysis method. Results: For the original plan, the magic phantom system was capable of measuring all dwell points and dwell times and the majority were found to be within 0.93 mm and 0.25 s, respectively, from the plan. By measuring the altered plan and comparing it to the unmodified treatment plan, the use of the position–time gamma index showed that all modifications made could be

  2. Braquiterapia endobrônquica de alta taxa de dose: estudo dosimétrico High dose-rate endobronchial brachytherapy: a dosimetric study

    Directory of Open Access Journals (Sweden)

    Regina Maria Godoy Lopes

    2010-02-01

    Full Text Available OBJETIVO: Avaliar a distribuição de dose em diferentes situações de braquiterapia endobrônquica de alta taxa de dose, com foco principalmente nos volumes de altas doses, e tentar definir situações de melhor ou pior distribuição de dose que possam servir de guia na prática clínica. MATERIAIS E MÉTODOS: Estudo teórico, simulando braquiterapia endobrônquica de alta taxa de dose utilizando dois cateteres, com variação da extensão de carregamento, angulação entre os cateteres, profundidade de cálculo e o intervalo entre as paradas da fonte. Com prescrição de 7,5 Gy, foram calculados os volumes englobados pelas isodoses correspondentes a 100%, 150% e 200% da dose prescrita (V100, V150 e V200, respectivamente e as razões V150/V100 e V200/V100. RESULTADOS: Os volumes aumentaram com o aumento da extensão de carregamento dos cateteres, profundidade de cálculo e angulação, com tendência a um aumento proporcionalmente menor para angulações maiores. As relações V150/V100 e V200/V100 foram, em geral, homogêneas, ao redor de 0,50 e 0,30, respectivamente. CONCLUSÃO: A distribuição de dose na situação considerada padrão é em geral adequada. Nenhum parâmetro específico que pudesse ser relacionado à maior toxicidade foi identificado. Recomendamos uma avaliação rápida da qualidade do implante por meio da análise das relações V150/V100 e V200/V100.OBJECTIVE: To evaluate the dose distribution in different situations of high dose-rate endobronchial brachytherapy, focusing especially on high-dose volumes, and try to identify better or worse situations in terms of dose distribution to aid as guidance in the clinical practice. MATERIALS AND METHODS: Theoretical study simulating high dose-rate endobronchial brachytherapy utilizing two catheters, varying the loading extent, angle between the catheters, prescription depth, and source step. With a prescription dose of 7.5 Gy, the volumes involved by the 100%, 150% and 200

  3. The evaluation of a 2D diode array in "magic phantom" for use in high dose rate brachytherapy pretreatment quality assurance.

    Science.gov (United States)

    Espinoza, A; Petasecca, M; Fuduli, I; Howie, A; Bucci, J; Corde, S; Jackson, M; Lerch, M L F; Rosenfeld, A B

    2015-02-01

    High dose rate (HDR) brachytherapy is a treatment method that is used increasingly worldwide. The development of a sound quality assurance program for the verification of treatment deliveries can be challenging due to the high source activity utilized and the need for precise measurements of dwell positions and times. This paper describes the application of a novel phantom, based on a 2D 11 × 11 diode array detection system, named "magic phantom" (MPh), to accurately measure plan dwell positions and times, compare them directly to the treatment plan, determine errors in treatment delivery, and calculate absorbed dose. The magic phantom system was CT scanned and a 20 catheter plan was generated to simulate a nonspecific treatment scenario. This plan was delivered to the MPh and, using a custom developed software suite, the dwell positions and times were measured and compared to the plan. The original plan was also modified, with changes not disclosed to the primary authors, and measured again using the device and software to determine the modifications. A new metric, the "position-time gamma index," was developed to quantify the quality of a treatment delivery when compared to the treatment plan. The MPh was evaluated to determine the minimum measurable dwell time and step size. The incorporation of the TG-43U1 formalism directly into the software allows for dose calculations to be made based on the measured plan. The estimated dose distributions calculated by the software were compared to the treatment plan and to calibrated EBT3 film, using the 2D gamma analysis method. For the original plan, the magic phantom system was capable of measuring all dwell points and dwell times and the majority were found to be within 0.93 mm and 0.25 s, respectively, from the plan. By measuring the altered plan and comparing it to the unmodified treatment plan, the use of the position-time gamma index showed that all modifications made could be readily detected. The MPh was able to

  4. Study of the radiation levels in low dose rate brachytherapy zones of the National Institute of Neoplastic Illnesses

    International Nuclear Information System (INIS)

    Figueroa J, N.; Mora Y, B.

    2006-01-01

    The present study has as objective to evaluate the radiation levels of the Brachytherapy work areas of low dose rate (Gammateque, nurses station and of hospitalization rooms of patients RIC of 4th, 5th Floor-East) and to estimate the effective dose of the occupationally exposed personnel and the public in general. The measurements of the dose rate in these areas, were registered with a radiations monitor Inspector trademark, during a period of 60 days, without altering the routinary work conditions. The more high levels of environmental dose equivalent rate registered in the different work areas its are of 1.41 and 47.78 μSv/h rooms 1 and 2 in the Gammateque environments, in the hospitalization rooms of the 4th and 5th floor in the point 1 are of 40.77 and 23.67, μSv/h respectively and in the point 2 are of 129.19 and 39.93, μSv/h respectively, and in the nurses station of the 4th and 5th floor its are respectively of 7.62 u Sv/h and 0.45 u Sv/h. According to the carried out measurements and the permanency in the work place is possible to estimate the effective dose involved to the occupationally exposed personnel. The personnel that works in Gammateque could be receiving respectively as maximum dose 0.61 mSv/month, and the personnel that works in the nurses station of 13.17 and 0.78 mSv/year in the 4th and 5th floor. These registered differences among the two floors are due to that the 5th floor counts with the shielding systems (screen) contrary to the 4th, another of the factors is the distribution form of the patient beds RIC. We should have present that the radiation levels although in some cases it is very high, however, they are below of the permissible limits according to standards, but it is still possible to reduce even more, the radiation levels in the critical points fulfilling with the ALARA principle. (Author)

  5. An evaluation of a Low-Dose-Rate (LDR) brachytherapy procedure using a systems engineering & error analysis methodology for health care (SEABH) - (SAVE)

    LENUS (Irish Health Repository)

    Chadwick, Liam

    2012-03-12

    Health Care Failure Modes and Effects Analysis (HFMEA®) is an established tool for risk assessment in health care. A number of deficiencies have been identified in the method. A new method called Systems and Error Analysis Bundle for Health Care (SEABH) was developed to address these deficiencies. SEABH has been applied to a number of medical processes as part of its validation and testing. One of these, Low Dose Rate (LDR) prostate Brachytherapy is reported in this paper. The case study supported the validity of SEABH with respect to its capacity to address the weaknesses of (HFMEA®).

  6. Innovation in gynaecological brachytherapy: new technologies, pulse dose-rate brachytherapy, image, definition of new volumes of interest and their impact on dosimetry: application in a clinical research programme 'S.T.I.C.'

    International Nuclear Information System (INIS)

    Haie-Meder, C.; Peiffert, D.

    2006-01-01

    Brachytherapy plays a fundamental role in the therapeutic approach of patients with stage I-IV cervical carcinoma. Technical modalities have evolved during the last decades: stepping source technology, imaging modalities development, specially IMN, treatment planning system integrating 3D images. Images from CT-Scan and MRI have contributed to a better knowledge of tumoral extension and critical organs. CT and/or MRI compatible applicators allow a sectional image based approach with a better definition of tumour volume compared to traditional approaches. The introduction of 3D image based approach for GTV and CTV requires new definitions and a common language. In 2000, a working group within GEC-ESTRO was created to support 3D image based 3D treatment planning approach in cervix cancer BT. The task was to determine a common terminology enabling various groups to use a common language. Recommendations were described and proposed based on clinical experience and dosimetric concepts of different institutions. Two CTVs were described en relation to the risk for recurrence: high-risk CTV and intermediate risk CTV. In order to better define the role of such definitions and their potential impact on the complication incidence in patients with cervical cancer, a special French programme was developed. The aim of this programme is to study the incidence of the severe 2-year complication rate in two comparable patient populations: one population is treated using PDR brachytherapy with CT-Scan or MRI with the applicators in place allowing a 3D dosimetry with optimization, the second population is treated using standard X-rays radiographs, without any delineation of the target nor optimisation. Each population arm includes 425 patients. A medico-economic assessment is performed, allowing a real cost of the most sophisticated approach compared to a historical dosimetric system. (author)

  7. Brachytherapy in childhood rhabdomyosarcoma treatment; Braquiterapia no tratamento do rabdomiossarcoma da infancia

    Energy Technology Data Exchange (ETDEWEB)

    Novaes, Paulo Eduardo Ribeiro dos Santos

    1995-07-01

    A retrospective study of 21 children with rhabdomyosarcoma treated by brachytherapy to the primary site of the tumor at the Radiotherapy Department of the A.C.Camargo Hospital between january/1980 to june/1993 was undertaken. The main objectives were to comprove the utility of brachytherapy in childhood rhabdomyosarcoma, to evaluate the local control and survival, in association with chemotherapy, to analyze the late effects of the treatment and to determinate the preferential technique to each clinical situation. All patients received brachytherapy to the tumor site. The radioactive isotopes employed were Gold{sup 198}, Cesium{sup 137} and Iridium{sup 192}. The brachytherapy techniques depended on the tumor site, period of treatment, availability of the radioactive material and stage of the disease. Patients treated exclusively by brachytherapy received 40 Gy to 60 Gy. When brachytherapy was associated with external radiotherapy the dose ranged from 20 Gy to 40 Gy. Local control was achieved in 18 of 20 patients (90%). The global survival and local control survival rates were 61.9% (13/21 patients) and 72,2% (13/18 patients) respectively. (author)

  8. After low and high dose-rate interstitial brachytherapy followed by IMRT radiotherapy for intermediate and high risk prostate cancer

    International Nuclear Information System (INIS)

    Nakamura, Satoshi; Murakami, Naoya; Inaba, Koji; Wakita, Akihisa; Kobayashi, Kazuma; Takahashi, Kana; Okamoto, Hiroyuki; Umezawa, Rei; Morota, Madoka; Sumi, Minako; Igaki, Hiroshi; Ito, Yoshinori; Itami, Jun

    2016-01-01

    The study aimed to compare urinary symptoms in patients with clinically localized prostate cancer after a combination of either low-dose-rate or high-dose-rate interstitial brachytherapy along with intensity-modulated radiation therapy (LDR-ISBT + IMRT or HDR-ISBT + IMRT). From June 2009 to April 2014, 16 and 22 patients were treated with LDR-ISBT + IMRT and HDR-ISBT + IMRT, respectively. No patient from these groups was excluded from this study. The prescribed dose of LDR-ISBT, HDR-ISBT, and IMRT was 115 Gy, 20 Gy in 2 fractions, and 46 Gy in 23 fractions, respectively. Obstructive and irritative urinary symptoms were assessed by the International Prostate Symptom Score (IPSS) examined before and after treatments. After ISBT, IPSS was evaluated in the 1st and 4th weeks, then every 2–3 months for the 1st year, and every 6 months thereafter. The median follow-up of the patients treated with LDR-ISBT + IMRT and HDR-ISBT + IMRT was 1070.5 days and 1048.5 days, respectively (p = 0.321). The IPSS-increment in the LDR-ISBT + IMRT group was greater than that in the HDR-ISBT + IMRT between 91 and 180 days after ISBT (p = 0.015). In the LDR-ISBT + IMRT group, the IPSS took longer time to return to the initial level than in the HDR-ISBT + IMRT group (in LDR-ISBT + IMRT group, the recovery time was 90 days later). The dose to urethra showed a statistically significant association with the IPSS-increment in the irritative urinary symptoms (p = 0.011). Clinical outcomes were comparable between both the groups. Both therapeutic modalities are safe and well suited for patients with clinically localized prostate cancer; however, it took patients longer to recover from LDR-ISBT + IMRT than from HDR-ISBT + IMRT. It is possible that fast dose delivery induced early symptoms and early recovery, while gradual dose delivery induced late symptoms and late recovery. Urethral dose reductions were associated with small increments in IPSS

  9. High dose rate brachytherapy using custom made superficial mould applicators and Leipzig applicators for non melanoma localized skin cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pellizzon, A. Cassio A.; Miziara, Daniela; Lima, Flavia Pedroso de; Miziara, Miguel

    2014-07-01

    Purpose: advances in technology and the commercial production of Leipzig applicators allowed High Dose Rate after-load brachytherapy (HDR-BT) to address a number of the challenges associated with the delivery of superficial radiation to treat localized non melanoma skin cancer (NMSK). We reviewed our uni-institutional experience on the treatment of NMSK with HDR-BT. Methods: data were collected retrospectively from patients attending the Radiation Oncology Department at AV Carvalho Insitute, Sao Paulo, Brazil. HDR-BT was done using the stepping source HDR 192Ir Microselectron (Nucletron BV). The planning target volume consisted of the macroscopic lesion plus a 5mm to 10mm margin.The depth of treatment was 0.5 cm in smaller (< 2.0 cm) tumors and 10 to 15 mm for lesions bigger than that. Results: Thirteen patients were treated with HDR-BT from June, 2007 to June 2013. The median age and follow up time were 72 (38-90) years old and 36 (range, 7-73) months, respectively. There a predominance of males (61.5%) and of patients referred for adjuvant treatment due positive surgical margins or because they have had only a excision biopsy without safety margins (61.5%). Six (46.2%) patients presented with squamous cell carcinoma and 7 (53.8%) patients presented with basal cell carcinoma. The median tumor size was 20 (range, 5-42) mm. Patients were treated with a median total dose of 40 Gy (range, 20 -60), given in 10 (range, 2-15) fractions, given daily or twice a week. All patients responded very well to treatment and only one patient has failed locally so far, after 38 months of the end of the irradiation. The crude and actuarial 3-year local control rates were 100% and 80%, respectively. Moist desquamation, grade 2 RTOG, was observed in 4 (30.8%) patients. Severe late complication, radiation-induced dyspigmentation, occurred in 2 patients and 1 of the patients also showed telangiectasia in the irradiated area. The cosmetic result was considered good in 84% (11/13) patients

  10. High dose rate brachytherapy using custom made superficial mould applicators and Leipzig applicators for non melanoma localized skin cancer

    International Nuclear Information System (INIS)

    Pellizzon, A. Cassio A.; Miziara, Daniela; Lima, Flavia Pedroso de; Miziara, Miguel

    2014-01-01

    Purpose: advances in technology and the commercial production of Leipzig applicators allowed High Dose Rate after-load brachytherapy (HDR-BT) to address a number of the challenges associated with the delivery of superficial radiation to treat localized non melanoma skin cancer (NMSK). We reviewed our uni-institutional experience on the treatment of NMSK with HDR-BT. Methods: data were collected retrospectively from patients attending the Radiation Oncology Department at AV Carvalho Insitute, Sao Paulo, Brazil. HDR-BT was done using the stepping source HDR 192Ir Microselectron (Nucletron BV). The planning target volume consisted of the macroscopic lesion plus a 5mm to 10mm margin.The depth of treatment was 0.5 cm in smaller (< 2.0 cm) tumors and 10 to 15 mm for lesions bigger than that. Results: Thirteen patients were treated with HDR-BT from June, 2007 to June 2013. The median age and follow up time were 72 (38-90) years old and 36 (range, 7-73) months, respectively. There a predominance of males (61.5%) and of patients referred for adjuvant treatment due positive surgical margins or because they have had only a excision biopsy without safety margins (61.5%). Six (46.2%) patients presented with squamous cell carcinoma and 7 (53.8%) patients presented with basal cell carcinoma. The median tumor size was 20 (range, 5-42) mm. Patients were treated with a median total dose of 40 Gy (range, 20 -60), given in 10 (range, 2-15) fractions, given daily or twice a week. All patients responded very well to treatment and only one patient has failed locally so far, after 38 months of the end of the irradiation. The crude and actuarial 3-year local control rates were 100% and 80%, respectively. Moist desquamation, grade 2 RTOG, was observed in 4 (30.8%) patients. Severe late complication, radiation-induced dyspigmentation, occurred in 2 patients and 1 of the patients also showed telangiectasia in the irradiated area. The cosmetic result was considered good in 84% (11/13) patients

  11. Preclinical study investigating the potential of low-dose-rate brachytherapy with32P stents for the prevention of restenosis of paranasal neo-ostia.

    Science.gov (United States)

    Oestreicher, Elmar; Bartsch, Harald; Mayr, Doris; Schubert, Mario; Weber, Barbara; Kneschaurek, Peter; Assmann, Walter; Sroka, Ronald; Betz, Christian Stephan

    Ostial restenosis is a common cause of failures in paranasal sinus surgery. The aim of the current study was to investigate the use of low-dose-rate brachytherapy to prevent neo-ostial restenosis in an animal model. In 14 rabbits, maxillary neo-ostia were created and measured. One side each was stented with a regular silicone stent, the other side was either not stented (n = 7) or stented with a phosphorous-32 implanted stent depositing a low-dose radiation of 15 Gy (n = 7) within 1 week, after which all stents were removed. After a period of additional 12 weeks of recovery, the animals were sacrificed, the neo-ostia were again measured, and the areas and histopathologic changes compared in between the groups. After 15-Gy stenting, the mean ostial areas were even slightly enlarged by 5.1% compared to the area at stent removal, whereas a significant reduction in area, indicating a process of restenosis, by 56.1% or 54.0% was seen in the control groups with no stent and normal stent, respectively. Furthermore, no indication for adverse histopathologic radiation effects was seen in the 15-Gy group. Low-dose-rate brachytherapy with phosphorous-32 doped silicone stents showed promising results in the prevention of neo-ostium restenosis in this proof-of-concept study, indicating that further preclinical and clinical testing may be warranted. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  12. Six fractions per week of external beam radiotherapy and high-dose-rate brachytherapy for carcinoma of the uterine cervix: A phase I/II study

    International Nuclear Information System (INIS)

    Yoon, Sang Min; Huh, Seung Jae; Park, Won; Lee, Jeung Eun; Park, Young Je; Nam, Hee Rim; Lim, Do Hoon; Ahn, Yong Chan

    2006-01-01

    Purpose: This study evaluated the treatment results of external beam radiotherapy administered in six fractions per week and high-dose-rate (HDR) brachytherapy for the treatment of cervical cancer. Methods and Materials: From July 2000 to July 2003, 43 patients were enrolled in this study. The patients received 45 Gy from a 10-MV photon beam using four-field box or anterior-posterior beams. Parametrial regions and the pelvic side walls were boosted with up to 50.4 Gy using a midline block. The daily fraction dose was 1.8 Gy administered in six-weekly fractions, from Monday to Saturday. HDR brachytherapy was also delivered at doses of 24 Gy to point A in six fractions twice a week. The median follow-up time was 37 months (range, 9-60 months). Results: The median overall treatment time was 51 days for all patients (range, 44-62 days). Thirty-four patients (79.1%) achieved complete remission and 8 (18.6%) achieved partial remission after radiotherapy. Locoregional recurrence occurred in 5 patients (11.6%), and a distant metastasis was encountered in 6 patients (13.9%). The 3-year overall survival, locoregional, and distant metastasis-free survival rates were 74.7%, 87.8%, and 84.7%, respectively. Grade 2 and 3 late rectal complications were encountered in 3 (6.5%) and 1 (2.2%), respectively. There were no Grade 3 late bladder complications. Conclusions: Six fractions per week of external beam radiotherapy and HDR brachytherapy is an effective treatment for patients with a carcinoma of the uterine cervix and can be used as a possible alternative to concomitant chemoradiotherapy in elderly patients or in patients with co-morbidity

  13. High dose-rate (HDR) conformal interstitial brachytherapy for locally recurrent rectal cancer. Real-time computed tomography (CT) fluoroscopy guidance and image-based treatment planning

    International Nuclear Information System (INIS)

    Sakurai, Hideyuki; Mitsuhashi, Norio; Muramatsu, Hiroyuki

    2000-01-01

    The aim of the study is to develop high dose-rate (HDR) conformal interstitial brachytherapy by means of combined real-time computed tomography (CT) fluoroscopy guidance with CT-based treatment planning for locally recurrent rectal carcinoma. The procedures of brachytherapy needle insertion were guided with a helical CT scanner providing real-time fluoroscopy reconstruction. A video monitor placed adjacent to the CT gantry simultaneously allowed the operator to see the process of needle insertion. CT images were transferred by an on-line system to the treatment-planning computer which reconstructed the implant needles and organ contours. The doses in planning target volume were normalized and geometrically optimized. The patients received a dose of 5 Gy per fraction on a daily hyperfractionation schedule at a total dose of 30-50 Gy with or without external radiation therapy. Nine patients were treated for this procedure. Thirteen to 36 needles (average 19.1) were successfully placed at the planning target volume in each patient. The average time for CT fluoroscopy was 370.1 seconds in each procedure. No accident was occurred during needle insertion, but one patient developed fibular nerve palsy after needle removal but gradually recovered. The CT-based treatment planning was faster and more accurate than projection reconstruction with conventional radiograms. Analysis of a dose volume histogram demonstrated conformal dose distribution of the target, while avoiding dose to normal structures with this method. Real-time CT fluoroscopy ensures safety and increases the accuracy of needle placement. Conformal high dose-rate (HDR) interstitial brachytherapy with CT-based treatment planning is an attractive method for locally recurrent rectal cancer. (author)

  14. High dose-rate (HDR) conformal interstitial brachytherapy for locally recurrent rectal cancer. Real-time computed tomography (CT) fluoroscopy guidance and image-based treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, Hideyuki; Mitsuhashi, Norio; Muramatsu, Hiroyuki [Gunma Univ., Maebashi (Japan). School of Medicine] [and others

    2000-12-01

    The aim of the study is to develop high dose-rate (HDR) conformal interstitial brachytherapy by means of combined real-time computed tomography (CT) fluoroscopy guidance with CT-based treatment planning for locally recurrent rectal carcinoma. The procedures of brachytherapy needle insertion were guided with a helical CT scanner providing real-time fluoroscopy reconstruction. A video monitor placed adjacent to the CT gantry simultaneously allowed the operator to see the process of needle insertion. CT images were transferred by an on-line system to the treatment-planning computer which reconstructed the implant needles and organ contours. The doses in planning target volume were normalized and geometrically optimized. The patients received a dose of 5 Gy per fraction on a daily hyperfractionation schedule at a total dose of 30-50 Gy with or without external radiation therapy. Nine patients were treated for this procedure. Thirteen to 36 needles (average 19.1) were successfully placed at the planning target volume in each patient. The average time for CT fluoroscopy was 370.1 seconds in each procedure. No accident was occurred during needle insertion, but one patient developed fibular nerve palsy after needle removal but gradually recovered. The CT-based treatment planning was faster and more accurate than projection reconstruction with conventional radiograms. Analysis of a dose volume histogram demonstrated conformal dose distribution of the target, while avoiding dose to normal structures with this method. Real-time CT fluoroscopy ensures safety and increases the accuracy of needle placement. Conformal high dose-rate (HDR) interstitial brachytherapy with CT-based treatment planning is an attractive method for locally recurrent rectal cancer. (author)

  15. Determination of the reference air kerma rate for 192Ir brachytherapy sources and the related uncertainty

    International Nuclear Information System (INIS)

    Dijk, Eduard van; Kolkman-Deurloo, Inger-Karine K.; Damen, Patricia M. G.

    2004-01-01

    Different methods exist to determine the air kerma calibration factor of an ionization chamber for the spectrum of a 192 Ir high-dose-rate (HDR) or pulsed-dose-rate (PDR) source. An analysis of two methods to obtain such a calibration factor was performed: (i) the method recommended by [Goetsch et al., Med. Phys. 18, 462-467 (1991)] and (ii) the method employed by the Dutch national standards institute NMi [Petersen et al., Report S-EI-94.01 (NMi, Delft, The Netherlands, 1994)]. This analysis showed a systematic difference on the order of 1% in the determination of the strength of 192 Ir HDR and PDR sources depending on the method used for determining the air kerma calibration factor. The definitive significance of the difference between these methods can only be addressed after performing an accurate analysis of the associated uncertainties. For an NE 2561 (or equivalent) ionization chamber and an in-air jig, a typical uncertainty budget of 0.94% was found with the NMi method. The largest contribution in the type-B uncertainty is the uncertainty in the air kerma calibration factor for isotope i, N k i , as determined by the primary or secondary standards laboratories. This uncertainty is dominated by the uncertainties in the physical constants for the average mass-energy absorption coefficient ratio and the stopping power ratios. This means that it is not foreseeable that the standards laboratories can decrease the uncertainty in the air kerma calibration factors for ionization chambers in the short term. When the results of the determination of the 192 Ir reference air kerma rates in, e.g., different institutes are compared, the uncertainties in the physical constants are the same. To compare the applied techniques, the ratio of the results can be judged by leaving out the uncertainties due to these physical constants. In that case an uncertainty budget of 0.40% (coverage factor=2) should be taken into account. Due to the differences in approach between the

  16. High-dose-rate Interstitial Brachytherapy Boost with a Pedicled Latissimus Dorsi Myocutaneous Flap for Myxofibrosarcoma of the Arm

    Directory of Open Access Journals (Sweden)

    Jordan D. Lane, BS

    2014-10-01

    Full Text Available Summary: A 71-year-old man was found to have a 7.4 × 2.9 × 7.0 cm myxofibrosarcoma of the right medial arm close to neurovascular structures. He received 50 Gray (Gy of preoperative external beam radiation. Radical resection resulted in a 15 × 10 cm defect. Nine brachytherapy catheters were placed, and a pedicled latissimus dorsi myocutaneous flap was used in reconstruction. Final pathology confirmed myxofibrosarcoma, high grade. The tumor was <1 mm from 2 margins. A total of 17.5 Gy of brachytherapy was delivered to the surgical bed from postoperative days 7 to 9. The flap developed fat necrosis distally which eventually required surgical debridement on postoperative day 58. It subsequently healed well and maintained good function of the limb. The patient remains under surveillance without evidence of recurrence.

  17. Design and implementation of a complementary treatment planning software for the GZP6 high dose rate brachytherapy system (GZP6 CTPS)

    International Nuclear Information System (INIS)

    Hariri Tabrizi, S.; Kamali Asl, A.; Azma, Z.

    2010-01-01

    Brachytherapy is one of the most common treatment modalities for gynecological cancer. The GZP6 brachytherapy system is one of the devices utilized in Iran. It has been considered particularly due to its low cost compared to other more complete and established systems. This system has some deficiencies including lack of a treatment planning software for non-predefined treatments, inability to change the gradually changeable dosimetric variables and using a point source estimation in dose calculation. This report presents a complementary treatment planning software to the system's own dedicated program. Material and Methods:. First, the dosimetric characteristics of three GZP6 sources were calculated based on the TG-43 protocol using the MCNP4C Monte Carlo code. Then, the calculated dose distribution around the implanted applicators, based on the selected dwell positions and dwell times, was shown in a graphical user interface written using the MATLAB software. Results: The computation uncertainty in the resulting TG-43 parameters was about 1% and the calculated parameters were in good agreement with similar studies on cobalt-60 source dosimetry. Furthermore, the graphical user interface is prepared as a user-friendly executable file which can be installed on any operating system. Discussion and Conclusion: Since different patients have distinct anatomy and physical conditions, a program for non-predefined situations of source arrangement is necessary. Using GZP6 complementary treatment planning software can satisfy this requirement.

  18. Prediction of late rectal complication following high-dose-rate intracavitary brachytherapy in cancer of the uterine cervix

    International Nuclear Information System (INIS)

    Lee, Jeung Eun; Huh, Seung Jae; Park, Won; Lim, Do Hoon; Ahn, Yong Chan

    2003-01-01

    Although high-dose-rate intracavitary radiotherapy (HDR ICR) has been used in the treatment of cervical cancer, the potential for increased risk of late complication, most commonly in the rectum, is a major concern. We have previously reported on 136 patients treated with HDR brachytherapy between 1995 and 1999. The purpose of this study is to upgrade the previous data and confirm the correlation between late rectal complication and rectal dose in cervix cancer patients treated with HDR ICR. A retrospective analysis was performed for 222 patients with cervix cancer who were treated for curative intent with extemal beam radiotherapy (EBRT) and HDR ICR from July 1995 to December 2001. The median dose of EBRT was 50.4 (30.6-56.4) Gy with a daily fraction size 1.8 Gy. A total of six fractions of HDR ICR were given twice weekly with fraction size of 4 (3-5.5) Gy to A point by Iridium-192 source. The rectal dose was calculated at the rectal reference point using the barium contrast criteria in vivo measurement of the rectal dose was performed with thermoluminescent dosimeter (TLD) during HDR ICR. The median follow-up period was 39 months, ranging from 6 to 90 months. Twenty-one patients (9.5%) experienced late rectal bleeding, from 3 to 44 months (median, 13 months) after the completion of RT. The calculated rectal doses were not different between the patients with rectal bleeding and those without, but the measured rectal doses were higher in the complicated patients. The differences of the measured ICR rectal fractional dose, ICR total rectal dose, and total rectal biologically equivalent dose (BED) were statistically significant. When the measured ICR total rectal dose was beyond 16 Gy, when the ratio of the measured rectal dose to A point dose was beyond 70%, or when the measured rectal BED was over 110 GY 3 , a high possibility of late rectal complication was found. Late rectal complication was closely correlated with measured rectal dose by in vivo dosimetry using

  19. Pulsed-dose-rate peri-operative brachytherapy as an interstitial boost in organ-sparing treatment of breast cancer

    Directory of Open Access Journals (Sweden)

    Krystyna Serkies

    2016-12-01

    Full Text Available Purpose : To evaluate peri-operative multicatheter interstitial pulsed-dose-rate brachytherapy (PDR-BT with an intra-operative catheter placement to boost the tumor excision site in breast cancer patients treated conservatively. Material and methods: Between May 2002 and October 2008, 96 consecutive T1-3N0-2M0 breast cancer patients underwent breast-conserving therapy (BCT including peri-operative PDR-BT boost, followed by whole breast external beam radiotherapy (WBRT. The BT dose of 15 Gy (1 Gy/pulse/h was given on the following day after surgery. Results: No increased bleeding or delayed wound healing related to the implants were observed. The only side effects included one case of temporary peri-operative breast infection and 3 cases of fat necrosis, both early and late. In 11 patients (11.4%, subsequent WBRT was omitted owing to the final pathology findings. These included eight patients who underwent mastectomy due to multiple adverse prognostic pathological features, one case of lobular carcinoma in situ, and two cases with no malignant tumor. With a median follow-up of 12 years (range: 7-14 years, among 85 patients who completed BCT, there was one ipsilateral breast tumor and one locoregional nodal recurrence. Six patients developed distant metastases and one was diagnosed with angiosarcoma within irradiated breast. The actuarial 5- and 10-year disease free survival was 90% (95% CI: 84-96% and 87% (95% CI: 80-94%, respectively, for the patients with invasive breast cancer, and 91% (95% CI: 84-97% and 89% (95% CI: 82-96%, respectively, for patients who completed BCT. Good cosmetic outcome by self-assessment was achieved in 58 out of 64 (91% evaluable patients. Conclusions : Peri-operative PDR-BT boost with intra-operative tube placement followed by EBRT is feasible and devoid of considerable toxicity, and provides excellent long-term local control. However, this strategy necessitates careful patient selection and histological confirmation

  20. Justification for inter-fraction correction of catheter movement in fractionated high dose-rate brachytherapy treatment of prostate cancer

    International Nuclear Information System (INIS)

    Simnor, Tania; Li, Sonia; Lowe, Gerry; Ostler, Peter; Bryant, Linda; Chapman, Caroline; Inchley, Dave; Hoskin, Peter J.

    2009-01-01

    Background and purpose: Fractionated high dose-rate (HDR) brachytherapy in the treatment of prostate cancer relies on reproducible catheter positions for each fraction to ensure adequate tumour coverage while minimising dose to normal tissues. Peri-prostatic oedema may cause caudal displacement of the catheters relative to the prostate gland between fractions. This can be corrected for by changing source dwell positions or by physical re-advancement of catheters before treatment. Materials and methods: Data for 20 consecutive monotherapy patients receiving three HDR fractions of 10.5 Gy per fraction over 2 days were analysed retrospectively. Pre-treatment CT scans were used to assess the effect of catheter movement between fractions on implant quality, with and without movement correction. Implant quality was evaluated using dosimetric parameters. Results: Compared to the first fraction (f1) the mean inter-fraction caudal movement relative to the prostate base was 7.9 mm (f2) (range 0-21 mm) and 3.9 mm (f3) (range 0-25.5 mm). PTV D90% was reduced without movement correction by a mean of 27.8% (f2) and 32.3% (f3), compared with 5.3% and 5.1%, respectively, with catheter movement correction. Dose to 2 cc of the rectum increased by a mean of 0.69 (f2) and 0.76 Gy (f3) compared with an increase of 0.03 and 0.04 Gy, respectively, with correction. The urethra V12 also increased by a mean of 0.36 (f2) and 0.39 Gy (f3) compared with 0.06 and 0.16 Gy, respectively, with correction. Conclusions: Inter-fraction correction for catheter movement using pre-treatment imaging is critical to maintain the quality of an implant. Without movement correction there is significant risk of tumour under-dosage and normal tissue over-dosage. The findings of this study justify additional imaging between fractions in order to carry out correction.

  1. Justification for inter-fraction correction of catheter movement in fractionated high dose-rate brachytherapy treatment of prostate cancer.

    Science.gov (United States)

    Simnor, Tania; Li, Sonia; Lowe, Gerry; Ostler, Peter; Bryant, Linda; Chapman, Caroline; Inchley, Dave; Hoskin, Peter J

    2009-11-01

    Fractionated high dose-rate (HDR) brachytherapy in the treatment of prostate cancer relies on reproducible catheter positions for each fraction to ensure adequate tumour coverage while minimising dose to normal tissues. Peri-prostatic oedema may cause caudal displacement of the catheters relative to the prostate gland between fractions. This can be corrected for by changing source dwell positions or by physical re-advancement of catheters before treatment. Data for 20 consecutive monotherapy patients receiving three HDR fractions of 10.5 Gy per fraction over 2 days were analysed retrospectively. Pre-treatment CT scans were used to assess the effect of catheter movement between fractions on implant quality, with and without movement correction. Implant quality was evaluated using dosimetric parameters. Compared to the first fraction (f1) the mean inter-fraction caudal movement relative to the prostate base was 7.9 mm (f2) (range 0-21 mm) and 3.9 mm (f3) (range 0-25.5 mm). PTV D90% was reduced without movement correction by a mean of 27.8% (f2) and 32.3% (f3), compared with 5.3% and 5.1%, respectively, with catheter movement correction. Dose to 2 cc of the rectum increased by a mean of 0.69 (f2) and 0.76 Gy (f3) compared with an increase of 0.03 and 0.04 Gy, respectively, with correction. The urethra V12 also increased by a mean of 0.36 (f2) and 0.39 Gy (f3) compared with 0.06 and 0.16 Gy, respectively, with correction. Inter-fraction correction for catheter movement using pre-treatment imaging is critical to maintain the quality of an implant. Without movement correction there is significant risk of tumour under-dosage and normal tissue over-dosage. The findings of this study justify additional imaging between fractions in order to carry out correction.

  2. Brachytherapy for cancer

    International Nuclear Information System (INIS)

    Nishio, Masamichi; Sakurai, Tomoyasu; Kagami, Yoshikazu; Narimatsu, Naoto

    1987-01-01

    Brachytherapy is one of most effective methods of radiotherapy for cancer, and therefore, low-dose-rate brachytherapy is widely used for carcinoma of the uterus and carcinoma of the tongue. Between 1974 and 1983, 76 primary thoracic esophageal squamous cell carcinomas were treated with external irradiation combined with additional intracavitary radium therapy at the National Sapporo Hospital. The esophageal primary control rate was 34 % and the 5-year survival rate was 24.1 %. We believe that external irradiation therapy followed by additional intracavitary radium irradiation produces good results. Also, from 1982, 30 patients with small residual or unresectable tumors received interstitial irradiation using an after-loading technique and iridium-192 seeds. Eighteen of these 30 patients treated with iridium-192 were recurrent cases, and 20 had outer tubes intra-operatively inserted into the tumor following iridium-192 irradiation. Ten of these patients had brain tumor, nine had cancer of the head and neck, and each of the remaining fifteen had the following malignancies : lung cancer, breast cancer, pancreatic cancer, bile duct cancer, uterus cancer, skin cancer and soft tissue sarcoma. Overall 4-year survival was 17.1 % in among the patients treated with Ir-192. Favorable preliminary results from these patients and those of various clinical trials on the extension of indications for brachytherapy were also reported. (author)

  3. Utilization rates of knee-arthroplasty in OECD countries.

    Science.gov (United States)

    Pabinger, C; Lothaller, H; Geissler, A

    2015-10-01

    The number of knee arthroplasties and the prevalence of obesity are increasing exponentially. To date there have been no published reviews on utilization rates of knee arthroplasty in OECD countries. We analysed economic, medical and population data relating to knee arthroplasty surgeries performed in OECD countries. Gross domestic product (GDP), health expenditures, obesity prevalence, knee arthroplasty utilization rates and growth in knee arthroplasty rates per 100,000 population were assessed for total population, for patients aged 65 years and over, and patients aged 64 years and younger. Obesity prevalence and utilization of knee arthroplasty have increased significantly in the past. The mean utilization rate of knee arthroplasty was 150 (22-235) cases per 100,000 total population in 2011. The strongest annual increase (7%) occurred in patients 64 years and under. Differences between individual countries can be explained by economic and medical patterns, with countries with higher medical expenditures and obesity prevalence having significantly higher utilization rates. Countries with lower utilization rates have significantly higher growth in utilization rates. The future demand for knee prostheses will increase x-fold by 2030, with exact rates dependant upon economic, social and medical factors. We observed a 10-fold variation in the utilization of knee arthroplasty among OECD countries. A significant and strong correlation of GDP, health expenditures and obesity prevalence with utilization of knee arthroplasty was found. Patients aged 64 years and younger show a two-fold higher growth rate in knee arthroplasty compared to the older population. This trend could result in a four-fold demand for knee arthroplasty in OECD countries by 2030. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  4. SU-F-T-65: AutomaticTreatment Planning for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

    International Nuclear Information System (INIS)

    Zhou, Y; Tan, J; Jiang, S; Albuquerque, K; Jia, X

    2016-01-01

    Purpose: High dose rate (HDR) brachytherapy treatment planning is conventionally performed in a manual fashion. Yet it is highly desirable to perform computerized automated planning to improve treatment planning efficiency, eliminate human errors, and reduce plan quality variation. The goal of this research is to develop an automatic treatment planning tool for HDR brachytherapy with a cylinder applicator for vaginal cancer. Methods: After inserting the cylinder applicator into the patient, a CT scan was acquired and was loaded to an in-house developed treatment planning software. The cylinder applicator was automatically segmented using image-processing techniques. CTV was generated based on user-specified treatment depth and length. Locations of relevant points (apex point, prescription point, and vaginal surface point), central applicator channel coordinates, and dwell positions were determined according to their geometric relations with the applicator. Dwell time was computed through an inverse optimization process. The planning information was written into DICOM-RT plan and structure files to transfer the automatically generated plan to a commercial treatment planning system for plan verification and delivery. Results: We have tested the system retrospectively in nine patients treated with vaginal cylinder applicator. These cases were selected with different treatment prescriptions, lengths, depths, and cylinder diameters to represent a large patient population. Our system was able to generate treatment plans for these cases with clinically acceptable quality. Computation time varied from 3–6 min. Conclusion: We have developed a system to perform automated treatment planning for HDR brachytherapy with a cylinder applicator. Such a novel system has greatly improved treatment planning efficiency and reduced plan quality variation. It also served as a testbed to demonstrate the feasibility of automatic HDR treatment planning for more complicated cases.

  5. SU-F-T-65: AutomaticTreatment Planning for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Y; Tan, J; Jiang, S; Albuquerque, K; Jia, X [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: High dose rate (HDR) brachytherapy treatment planning is conventionally performed in a manual fashion. Yet it is highly desirable to perform computerized automated planning to improve treatment planning efficiency, eliminate human errors, and reduce plan quality variation. The goal of this research is to develop an automatic treatment planning tool for HDR brachytherapy with a cylinder applicator for vaginal cancer. Methods: After inserting the cylinder applicator into the patient, a CT scan was acquired and was loaded to an in-house developed treatment planning software. The cylinder applicator was automatically segmented using image-processing techniques. CTV was generated based on user-specified treatment depth and length. Locations of relevant points (apex point, prescription point, and vaginal surface point), central applicator channel coordinates, and dwell positions were determined according to their geometric relations with the applicator. Dwell time was computed through an inverse optimization process. The planning information was written into DICOM-RT plan and structure files to transfer the automatically generated plan to a commercial treatment planning system for plan verification and delivery. Results: We have tested the system retrospectively in nine patients treated with vaginal cylinder applicator. These cases were selected with different treatment prescriptions, lengths, depths, and cylinder diameters to represent a large patient population. Our system was able to generate treatment plans for these cases with clinically acceptable quality. Computation time varied from 3–6 min. Conclusion: We have developed a system to perform automated treatment planning for HDR brachytherapy with a cylinder applicator. Such a novel system has greatly improved treatment planning efficiency and reduced plan quality variation. It also served as a testbed to demonstrate the feasibility of automatic HDR treatment planning for more complicated cases.

  6. Interstitial prostate brachytherapy. LDR-PDR-HDR

    International Nuclear Information System (INIS)

    Kovacs, Gyoergy; Hoskin, Peter

    2013-01-01

    The first comprehensive overview of interstitial brachytherapy for the management of local or locally advanced prostate cancer. Written by an interdisciplinary team who have been responsible for the successful GEC-ESTRO/EAU Teaching Course. Discusses in detail patient selection, the results of different methods, the role of imaging, and medical physics issues. Prostate brachytherapy has been the subject of heated debate among surgeons and the proponents of the various brachytherapy methods. This very first interdisciplinary book on the subject provides a comprehensive overview of innovations in low dose rate (LDR), high dose rate (HDR), and pulsed dose rate (PDR) interstitial brachytherapy for the management of local or locally advanced prostate cancer. In addition to detailed chapters on patient selection and the use of imaging in diagnostics, treatment guidance, and implantation control, background chapters are included on related medical physics issues such as treatment planning and quality assurance. The results obtained with the different treatment options and the difficult task of salvage treatment are fully discussed. All chapters have been written by internationally recognized experts in their fields who for more than a decade have formed the teaching staff responsible for the successful GEC-ESTRO/EAU Prostate Brachytherapy Teaching Course. This book will be invaluable in informing residents and others of the scientific background and potential of modern prostate brachytherapy. It will also prove a useful source of up-to-date information for those who specialize in prostate brachytherapy or intend to start an interstitial brachytherapy service.

  7. Impact of age on quality of life in patients with localized prostate cancer treated with high-dose rate brachytherapy combined with external beam radiotherapy.

    Science.gov (United States)

    Kikkawa, Kazuro; Iba, Akinori; Kohjimoto, Yasuo; Noda, Yasutaka; Sonomura, Tetsuo; Hara, Isao

    2018-02-04

    To evaluate age-related quality of life changes in patients with localized prostate cancer treated by high-dose rate brachytherapy combined with external beam radiation therapy. A total of 172 patients with clinically localized prostate cancer were categorized to age groups <75 years and ≥75 years. Changes in their quality of life were evaluated using the Japanese version of Medical Outcome Study 8-Items Short Form Health Survey, Expanded Prostate Cancer Index Composite and International Index of Erectile Function-5 at baseline, and followed up to 24 months after treatment. There were no significant differences in Medical Outcome Study 8-Items Short Form Health Survey scores, and urinary and bowel scores of the Expanded Prostate Cancer Index Composite for older men after treatment. International Index of Erectile Function-5 summary scores were significantly decreased in both groups. Although sexual function and sexual bother scores were decreased in patients aged <75 years, these scores were maintained in patients aged ≥75 years. Quality of life of prostate cancer patients undergoing high-dose rate brachytherapy combined with external beam radiation therapy does not seem to be significantly affected by age. © 2018 The Japanese Urological Association.

  8. Pulse dose-rate brachytherapy and treatment of uterine cervix cancer: impact of a 3D or a 2D dosimetric support

    International Nuclear Information System (INIS)

    Tournat, H.; Chilles, A.; Charra-Brunaud, C.; Peiffert, D.; Ahmad, F.; Metayer, Y.

    2007-01-01

    Purpose To evaluate two dosimetric supports used in pulse dose rate brachytherapy (P.D.R.): coverage of target volumes, dose to organs at risk, residual tumor after surgery, survival. Patients and methods Twenty patients treated for uterine cervix tumor first by brachytherapy P.D.R. had a dosimetric CT-scan after implantation. For 9 patients, the treatment was planned from standard radiographies and then reported on CT-scan images. For 11 patients, it was directly planned from CT-scan. Six weeks after, 18 patients underwent surgery. Results With a median follow-up of 22 months, 2 year actuarial survival was 89%. Six patients developed grade II urinary or gynecological complications (LENT SOMA scale). No residual tumor was found for 12 patients (7 with a 3D treatment and 5 a 2 D treatment). Ninety-five percent of C.T.V.H.R. received 53 Gy (2D treatment) or 63 Gy (3D treatment). Two cm 3 of bladder wall received 63 Gy (2D) or 74 Gy (3D) although 2 cm 3 of rectal wall received 37 Gy (2D) and 35 Gy (3D). Conclusion Using CT-scan made us improve the coverage of the uterine cervix but increase the dose received by the bladder, without increasing the rate of histological remission after surgery. We should be prudent before changing our practice. (authors)

  9. Late rectal bleeding and genitourinary morbidity after high dose rate brachytherapy combined with hypofractionated external beam radiotherapy for localized prostate cancer

    International Nuclear Information System (INIS)

    Ebara, Takeshi; Akimoto, Tetsuo; Kato, Hiroyuki

    2007-01-01

    The purpose of this study was to evaluate late rectal bleeding and genitourinary (GU) morbidity in patients consecutively treated with combined high-dose-rate (HDR) brachytherapy and external beam radiation therapy (EBRT). Data from 80 patients treated consecutively from October 2000 to May 2004 were analyzed. The median age was 69 years old, median follow-up 31 months, ranging from 17-59 months. All patients received endocrine therapy before radiation therapy. The patients were divided into low-, intermediate- and high-risk groups (4/24/52 patients) according to the risk factors defined by T-classification, prostatic specific antigen (PSA) and Gleason score. Fractionation schedules for HDR brachytherapy were prospectively changed, and EBRT was fixed with 3 Gy fractions to 51 Gy. The distribution of fractionation was scheduled as follows; 5 Gy x 5 times in 14 patients, 7 Gy x 3 times in 19 patients, and 9 Gy x 2 times in 47 patients. The rectal bleeding was graded using the toxicity criteria of the Radiation Therapy Oncology Group and European Organization for Research and Treatment of Cancer while the genitourinary morbidities were graded using the toxicity criteria of the Common Terminology Criteria for Adverse Events v.3.0. Grade 2 or worse rectal bleeding developed in 9 patients (11.3%) with the 2-year actuarial probability at 11.2%. Grade 2 and 3 rectal bleeding was recognized in 8 and 1 patients, respectively. Grade 3 morbidity developed in the biopsied sites that were performed in the other hospital. No significant difference was observed in any HDR brachytherapy fractionation schedule. Grade 2 or worse GU morbidities were recognized in 30 patients (37.5%), consisting of 29 Grade 2 patients and 1 Grade 3 patient. Twenty-one patients in Grade 2 morbidity had an increase in the frequency of urination or nocturia, and urethral strictures developed in 3 patients. The 3-year actuarial probability of urethral stricture was 6.0%. One patient experienced Grade 3

  10. Long term results of a prospective dose escalation phase-II trial: Interstitial pulsed-dose-rate brachytherapy as boost for intermediate- and high-risk prostate cancer

    International Nuclear Information System (INIS)

    Lettmaier, Sebastian; Lotter, Michael; Kreppner, Stephan; Strnad, Annedore; Fietkau, Rainer; Strnad, Vratislav

    2012-01-01

    Purpose: We reviewed our seven year single institution experience with pulsed dose rate brachytherapy dose escalation study in patients with intermediate and high risk prostate cancer. Materials and methods: We treated a total of 130 patients for intermediate and high risk prostate cancer at our institution between 2000 and 2007 using PDR-brachytherapy as a boost after conformal external beam radiation therapy to 50.4 Gy. The majority of patients had T2 disease (T1c 6%, T2 75%, T3 19%). Seventy three patients had intermediate-risk and 53 patients had high-risk disease according to the D’Amico classification. The dose of the brachytherapy boost was escalated from 25 to 35 Gy – 33 pts. received 25 Gy (total dose 75 Gy), 63 pts. 30 Gy (total dose 80 Gy) and 34 pts. 35 Gy, (total dose 85 Gy) given in one session (dose per pulse was 0.60 Gy or 0.70 Gy/h, 24 h per day, night and day, with a time interval of 1 h between two pulses). PSA-recurrence-free survival according to Kaplan–Meier using the Phoenix definition of biochemical failure was calculated and also late toxicities according to Common Toxicity Criteria scale were assessed. Results: At the time of analysis with a median follow-up of 60 months biochemical control was achieved by 88% of patients – only 16/130 patients (12.3%) developed a biochemical relapse. Biochemical relapse free survival calculated according to Kaplan–Meier for all patients at 5 years was 85.6% (83.9% for intermediate-risk patients and 84.2% for high-risk patients) and at 9 years’ follow up it was 79.0%. Analysing biochemical relapse free survival separately for different boost dose levels, at 5 years it was 97% for the 35 Gy boost dose and 82% for the 25 and 30 Gy dose levels. The side effects of therapy were negligible: There were 18 cases (15%) of grade 1/2 rectal proctitis, one case (0.8%) of grade 3 proctitis, 18 cases (15%) of grade 1/2 cystitis, and no cases (0%) with dysuria grade 3. No patient had a bulbourethral

  11. Comparison of absorbed dose in the cervix carcinoma therapy by brachytherapy of high dose rate using the conventional planning and Monte Carlo simulation

    International Nuclear Information System (INIS)

    Silva, Aneli Oliveira da

    2010-01-01

    This study aims to compare the doses received for patients submitted to brachytherapy High Dose Rate (HDR) brachytherapy, a method of treatment of the cervix carcinoma, performed in the planning system PLATO BPS with the doses obtained by Monte Carlo simulation using the radiation transport code MCNP 5 and one female anthropomorphic phantom based on voxel, the FAX. The implementation of HDR brachytherapy treatment for the cervix carcinoma consists of the insertion of an intrauterine probe and an intravaginal probe (ring or ovoid) and then two radiographs are obtained, anteroposterior (AP) and lateral (LAT) to confirm the position of the applicators in the patient and to allow the treatment planning and the determination of the absorbed dose at points of interest: rectum, bladder, sigmoid and point A, which corresponds anatomically to the crossings of the uterine arteries with ureters The absorbed doses obtained with the code MCNP 5, with the exception of the absorbed dose in the rectum and sigmoid for the simulation considering a point source of 192 Ir, are lower than the absorbed doses from PLATO BPS calculations because the MCNP 5 considers the chemical compositions and densities of FAX body, not considering the medium as water. When considering the Monte Carlo simulation for a source with dimensions equal to that used in the brachytherapy irradiator used in this study, the values of calculated absorbed dose to the bladder, to the rectum, to the right point A and to the left point A were respectively lower than those determined by the treatment planning system in 33.29, 5.01, 22.93 and 19.04%. These values are almost all larger than the maximum acceptable deviation between patient planned and administered doses (5 %). With regard to the rectum and bladder, which are organs that must be protected, the present results are in favor of the radiological protection of patients. The point A, that is on the isodose of 100%, used to tumor treatment, the results indicate

  12. SU-G-201-06: Directional Low-Dose Rate Brachytherapy: Determination of the TG-43 Dose-Rate Constant Analog for a New Pd-103 Source

    Energy Technology Data Exchange (ETDEWEB)

    Aima, M; Culberson, W; Hammer, C; Micka, J; DeWerd, L [Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI (United States)

    2016-06-15

    Purpose: The aim of this work is to determine the TG-43 dose-rate constant analog for a new directional low-dose rate brachytherapy source based on experimental methods and comparison to Monte Carlo simulations. The CivaSheet™ is a new commercially available planar source array comprised of a variable number of discrete directional source elements called “CivaDots”. Given the directional nature and non-conventional design of the source, modifications to the AAPM TG-43 protocol for dosimetry are required. As a result, various parameters of the TG-43 dosimetric formalism have to be adapted to accommodate this source. This work focuses on the dose-rate constant analog determination for a CivaDot. Methods: Dose to water measurements of the CivaDot were performed in a polymethyl methacrylate phantom (20×20×12 cm{sup 3}) using thermoluminescent dosimeters (TLDs) and Gafchromic EBT3 film. The source was placed in the center of the phantom, and nine TLD micro-cubes were irradiated along its central axis at a distance of 1 cm. For the film measurements, the TLDs were substituted by a (3×3) cm{sup 2} EBT3 film. Primary air-kerma strength measurements of the source were performed using a variable-aperture free-air chamber. Finally, the source was modeled using the Monte Carlo N-Particle Transport Code 6. Results: Dose-rate constant analog observed for a total of eight CivaDots using TLDs and five CivaDots using EBT3 film was within ±7.0% and ±2.9% of the Monte Carlo predicted value respectively. The average difference observed was −4.8% and −0.1% with a standard deviation of 1.7% and 2.1% for the TLD and the film measurements respectively, which are both within the comparison uncertainty. Conclusion: A preliminary investigation to determine the doserate constant analog for a CivaDot was conducted successfully with good agreement between experimental and Monte Carlo based methods. This work will aid in the eventual realization of a clinically-viable dosimetric

  13. Failure modes and effects analysis in image-guided high-dose-rate brachytherapy: Quality control optimization to reduce errors in treatment volume.

    Science.gov (United States)

    Wadi-Ramahi, Shada; Alnajjar, Waleed; Mahmood, Rana; Jastaniyah, Noha; Moftah, Belal

    2016-01-01

    Analyze the inputs which cause treatment to the wrong volume in high-dose-rate brachytherapy (HDRB), with emphasis on imaging role during implant, planning, and treatment verification. The end purpose is to compare our current practice to the findings of the study and apply changes where necessary. Failure mode and effects analysis was used to study the failure pathways for treating the wrong volume in HDRB. The role of imaging and personnel was emphasized, and subcategories were formed. A quality assurance procedure is proposed for each high-scoring failure mode (FM). Forty FMs were found that lead to treating the wrong volume. Of these, 73% were human failures, 20% were machine failures, and 7% were procedural/guideline failures. The use of imaging was found to resolve 85% of the FMs. We also noted that imaging processes were under used in current practice of HDRB especially in pretreatment verification. Twelve FMs (30%) scored the highest, and for each one of them, we propose clinical/practical solutions that could be applied to reduce the risk by increasing detectability. This work resulted in two conclusions: the role of imaging in improving failure detection and the emphasized role of human-based failures. The majority of FMs are human failures, and imaging increased the ability to detect 85% of all FMs. We proposed quality assurance practices for each high-scoring FM and have implemented some of them in our own practice. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  14. 3-D conformal treatment of prostate cancer to 74 Gy vs. high-dose-rate brachytherapy boost: A cross-sectional quality-of-life survey

    International Nuclear Information System (INIS)

    Vordermark, Dirk

    2006-01-01

    The effects of two modalities of dose-escalated radiotherapy on health-related quality of life (HRQOL) were compared. Forty-one consecutive patients were treated with a 3-D conformal (3-DC) boost to 74 Gy, and 43 with high-dose rate (HDR) brachytherapy boost (2x9 Gy), following 3-D conformal treatment to 46 Gy. Median age was 70 years in both groups, median initial PSA was 7.9 μg/l in 3-DC boost patients and 8.1 μg/l in HDR boost patients. Stage was 7 in 52% and 47%, respectively. HRQOL was assessed cross-sectionally using EORTC QLQ-C30 and organ-specific PR25 modules 3-32 (median 19) and 4-25 (median 14) months after treatment, respectively. Questionnaires were completed by 93% and 97% of patients, respectively. Diarrhea and insomnia scores were significantly increased in both groups. In the PR25 module, scores of 3-DC boost and HDR boost patients for urinary, bowel and treatment-related symptoms were similar. Among responders, 34% of 3-DC boost patients and 86% of HDR boost patients had severe erectile problems. Dose escalation in prostate cancer by either 3-DC boost to 74 Gy or HDR brachytherapy boost appears to result in similar HRQOL profiles

  15. 3-D conformal treatment of prostate cancer to 74 Gy vs. high-dose-rate brachytherapy boost: A cross-sectional quality-of-life survey

    Energy Technology Data Exchange (ETDEWEB)

    Vordermark, Dirk [Univ. of Wuerzburg (DE). Dept. of Radiation Oncology] (and others)

    2006-09-15

    The effects of two modalities of dose-escalated radiotherapy on health-related quality of life (HRQOL) were compared. Forty-one consecutive patients were treated with a 3-D conformal (3-DC) boost to 74 Gy, and 43 with high-dose rate (HDR) brachytherapy boost (2x9 Gy), following 3-D conformal treatment to 46 Gy. Median age was 70 years in both groups, median initial PSA was 7.9 {mu}g/l in 3-DC boost patients and 8.1 {mu}g/l in HDR boost patients. Stage was 7 in 52% and 47%, respectively. HRQOL was assessed cross-sectionally using EORTC QLQ-C30 and organ-specific PR25 modules 3-32 (median 19) and 4-25 (median 14) months after treatment, respectively. Questionnaires were completed by 93% and 97% of patients, respectively. Diarrhea and insomnia scores were significantly increased in both groups. In the PR25 module, scores of 3-DC boost and HDR boost patients for urinary, bowel and treatment-related symptoms were similar. Among responders, 34% of 3-DC boost patients and 86% of HDR boost patients had severe erectile problems. Dose escalation in prostate cancer by either 3-DC boost to 74 Gy or HDR brachytherapy boost appears to result in similar HRQOL profiles.

  16. Radiological protection on interstitial brachytherapy and dose determination and exposure rate of an Ir-192 source through the MCNP-4B

    International Nuclear Information System (INIS)

    Morales L, M.E.

    2006-01-01

    The present work was carried out in the Neurological Sciences Institute having as objective to determine the dose and the rate of exhibition of the sources of Iridium 192, Iodine 125 and Palladium 103; which are used to carry out implant in the Interstitial Brachytherapy according to the TG43. For it we carry out a theoretical calculation, its are defined in the enter file: the geometry, materials of the problem and the radiation source, etc; in the MCNP-4B Monte Carlo code, considering a punctual source and for the dose determination we simulate thermoluminescent dosemeters (TLD): at 5 cm, 50 cm, 100 cm and 200 cm of the source. Our purpose is to analyze the radioprotection measures that should take into account in this Institute in which are carried out brain biopsies using a Micro mar stereotactic mark, and in a near future with the collaboration of a doctor and a cuban physique seeks to be carried out the Interstitial Brachytherapy technique with sources of Ir-192 for patient with tumors like glioblastoma, astrocytoma, etc. (Author)

  17. A dosimetric analysis of intensity-modulated radiation therapy (IMRT) as an alternative to adjuvant high-dose-rate (HDR) brachytherapy in early endometrial cancer patients.

    Science.gov (United States)

    Aydogan, Bulent; Mundt, Arno J; Smith, Brett D; Mell, Loren K; Wang, Steve; Sutton, Harold; Roeske, John C

    2006-05-01

    To evaluate the role of intensity-modulated radiation treatment (IMRT) as an alternative to high-dose-rate (HDR) brachytherapy in the treatment of the vagina in postoperative early endometrial cancer patients after surgery. Planning computed tomography (CT) scans of 10 patients previously treated with HDR were used in this study. In all cases, a dose of 700 cGy/fraction was prescribed at a distance of 0.5 cm from the cylinder surface. The same CT scans were then used in IMRT planning. In this paradigm, the vaginal cylinder represents a component of a hypothetical immobilization system that would be indexed to the linac treatment table. Our study showed that IMRT provided relatively lower rectal doses than HDR when treatment was prescribed at a distance of 0.5 cm away from the cylinder surface. Maximum rectal doses were lower with IMRT compared with HDR (average: 89.0% vs. 142.6%, respectively, p in IMRT plans compared with HDR plans with treatment prescribed either to the surface (average: 14.8% vs. 21.4%, respectively, p in conjunction with a suitable immobilization system, IMRT may provide an alternative to HDR brachytherapy in women with early endometrial cancer after hysterectomy. However, more studies are needed to evaluate the clinical merit of the IMRT in these patients.

  18. Prostate-specific antigen nadir after high-dose-rate brachytherapy predicts long-term survival outcomes in high-risk prostate cancer

    Directory of Open Access Journals (Sweden)

    Hideyasu Tsumura

    2016-04-01

    Full Text Available Purpose : To evaluate the prognostic value of prostate-specific antigen nadir (nPSA after high-dose-rate (HDR brachytherapy in clinically non-metastatic high-risk prostate cancer patients. Material and methods : Data from 216 patients with high-risk or locally advanced prostate cancer who underwent HDR brachytherapy and external beam radiation therapy with long-term androgen deprivation therapy (ADT between 2003 and 2008 were analyzed. The median prostate-specific antigen (PSA level at diagnosis was 24 ng/ml (range: 3-338 ng/ml. The clinical stage was T1c-2a in 55 cases (26%, T2b-2c in 48 (22%, T3a in 75 (35%, and T3b-4 in 38 (17%. The mean dose to 90% of the planning target volume was 6.3 Gy/fraction of HDR brachytherapy. After 5 fractions, external beam radiation therapy with 10 fractions of 3 Gy was administered. All patients initially underwent neoadjuvant ADT for at least 6 months, and adjuvant ADT was continued for 36 months. The median follow-up was 7 years from the start of radiotherapy. Results : The 7-year PSA relapse-free rate among patients with a post-radiotherapy nPSA level of ≤ 0.02 ng/ml was 94%, compared with 23% for patients with higher nPSA values (HR = 28.57; 95% CI: 12.04-66.66; p < 0.001. Multivariate analysis revealed that the nPSA value after radiotherapy was a significant independent predictor of biochemical failure, whereas pretreatment predictive values for worse biochemical control including higher level of initial PSA, Gleason score ≥ 8, positive biopsy core rate ≥ 67%, and T3b-T4, failed to reach independent predictor status. The 7-year cancer-specific survival rate among patients with a post-radiotherapy nPSA level of ≤ 0.02 ng/ml was 99%, compared with 82% for patients with higher nPSA values (HR = 32.25; 95% CI: 3.401-333.3; p = 0.002. Conclusions : A post-radiotherapy nPSA value of ≤ 0.02 ng/ml was associated with better long-term biochemical tumor control even if patients had pretreatment predictive

  19. Accelerated Partial Breast Irradiation With Low-Dose-Rate Interstitial Implant Brachytherapy After Wide Local Excision: 12-Year Outcomes From a Prospective Trial

    International Nuclear Information System (INIS)

    Hattangadi, Jona A.; Powell, Simon N.; MacDonald, Shannon M.; Mauceri, Thomas; Ancukiewicz, Marek; Freer, Phoebe; Lawenda, Brian; Alm El-Din, Mohamed A.; Gadd, Michele A.; Smith, Barbara L.; Taghian, Alphonse G.

    2012-01-01

    Purpose: To evaluate the long-term toxicity, cosmesis, and local control of accelerated partial breast irradiation with implant brachytherapy after wide local excision for Stage T1N0 breast cancer (BCa). Materials and Methods: Between 1997 and 2001, 50 patients with Stage T1N0M0 BCa were treated in a Phase I-II protocol using low-dose-rate accelerated partial breast irradiation with implant brachytherapy after wide local excision and lymph node surgery. The total dose was escalated in three groups: 50 Gy (n = 20), 55 Gy (n = 17), and 60 Gy (n = 13). Patient- and physician-assessed breast cosmesis, patient satisfaction, toxicity, mammographic abnormalities, repeat biopsies, and disease status were prospectively evaluated at each visit. Kendall’s tau (τ β ) and logistic regression analyses were used to correlate outcomes with dose, implant volume, patient age, and systemic therapy. Results: The median follow-up period was 11.2 years (range, 4–14). The patient satisfaction rate was 67%, 67% reported good-excellent cosmesis, and 54% had moderate-severe fibrosis. Higher dose was correlated with worse cosmetic outcome (τ β 0.6, p β 0.5, p β 0.4, p = .0024). Of the 50 patients, 35% had fat necrosis and 34% developed telangiectasias ≥1 cm 2 . Grade 3–4 late skin and subcutaneous toxicities were seen in 4 patients (9%) and 6 patients (13%), respectively, and both correlated with higher dose (τ β 0.3–0.5, p ≤ .01). One patient had Grade 4 skin ulceration and fat necrosis requiring surgery. Mammographic abnormalities were seen in 32% of the patients, and 30% underwent repeat biopsy, of which 73% were benign. Six patients had ipsilateral breast recurrence: five elsewhere in the breast, and one at the implant site. One patient died of metastatic BCa after recurrence. The 12-year actuarial local control, recurrence-free survival, and overall survival rate was 85% (95% confidence interval, 70–97%), 72% (95% confidence interval, 54–86%), and 87% (95

  20. Accelerated Partial Breast Irradiation With Low-Dose-Rate Interstitial Implant Brachytherapy After Wide Local Excision: 12-Year Outcomes From a Prospective Trial

    Energy Technology Data Exchange (ETDEWEB)

    Hattangadi, Jona A. [Harvard Radiation Oncology Program, Boston, MA (United States); Powell, Simon N. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); MacDonald, Shannon M.; Mauceri, Thomas; Ancukiewicz, Marek [Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA (United States); Freer, Phoebe [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Lawenda, Brian [21st Century Oncology, Las Vegas, NV (United States); Alm El-Din, Mohamed A. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Department of Clinical Oncology, Tanta University Hospital, Tanta (Egypt); Gadd, Michele A.; Smith, Barbara L. [Department of Surgical Oncology, Massachusetts General Hospital, Boston, MA (United States); Taghian, Alphonse G., E-mail: ataghian@partners.org [Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA (United States)

    2012-07-01

    Purpose: To evaluate the long-term toxicity, cosmesis, and local control of accelerated partial breast irradiation with implant brachytherapy after wide local excision for Stage T1N0 breast cancer (BCa). Materials and Methods: Between 1997 and 2001, 50 patients with Stage T1N0M0 BCa were treated in a Phase I-II protocol using low-dose-rate accelerated partial breast irradiation with implant brachytherapy after wide local excision and lymph node surgery. The total dose was escalated in three groups: 50 Gy (n = 20), 55 Gy (n = 17), and 60 Gy (n = 13). Patient- and physician-assessed breast cosmesis, patient satisfaction, toxicity, mammographic abnormalities, repeat biopsies, and disease status were prospectively evaluated at each visit. Kendall's tau ({tau}{sub {beta}}) and logistic regression analyses were used to correlate outcomes with dose, implant volume, patient age, and systemic therapy. Results: The median follow-up period was 11.2 years (range, 4-14). The patient satisfaction rate was 67%, 67% reported good-excellent cosmesis, and 54% had moderate-severe fibrosis. Higher dose was correlated with worse cosmetic outcome ({tau}{sub {beta}} 0.6, p < .0001), lower patient satisfaction ({tau}{sub {beta}} 0.5, p < .001), and worse fibrosis ({tau}{sub {beta}} 0.4, p = .0024). Of the 50 patients, 35% had fat necrosis and 34% developed telangiectasias {>=}1 cm{sup 2}. Grade 3-4 late skin and subcutaneous toxicities were seen in 4 patients (9%) and 6 patients (13%), respectively, and both correlated with higher dose ({tau}{sub {beta}} 0.3-0.5, p {<=} .01). One patient had Grade 4 skin ulceration and fat necrosis requiring surgery. Mammographic abnormalities were seen in 32% of the patients, and 30% underwent repeat biopsy, of which 73% were benign. Six patients had ipsilateral breast recurrence: five elsewhere in the breast, and one at the implant site. One patient died of metastatic BCa after recurrence. The 12-year actuarial local control, recurrence

  1. Preventing Complications from High-Dose Rate Brachytherapy when Treating Mobile Tongue Cancer via the Application of a Modular Lead-Lined Spacer.

    Directory of Open Access Journals (Sweden)

    Shumei Murakami

    Full Text Available To point out the advantages and drawbacks of high-dose rate brachytherapy in the treatment of mobile tongue cancer and indicate the clinical importance of modular lead-lined spacers when applying this technique to patients.First, all basic steps to construct the modular spacer are shown. Second, we simulate and evaluate the dose rate reduction for a wide range of spacer configurations.With increasing distance to the source absorbed doses dropped considerably. Significantly more shielding was obtained when lead was added to the spacer and this effect was most pronounced on shorter (i.e. more clinically relevant distances to the source.The modular spacer represents an important addition to the planning and treatment stages of mobile tongue cancer using HDR-ISBT.

  2. Erectile function after prostate brachytherapy

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Wallner, Kent E.; Galbreath, Robert W.; Anderson, Richard L.; Kurko, Brian S.; Lief, Jonathan H.; Allen, Zachariah A.

    2005-01-01

    Purpose: To evaluate erectile function after permanent prostate brachytherapy using a validated patient-administered questionnaire and to determine the effect of multiple clinical, treatment, and dosimetric parameters on penile erectile function. Methods and materials: A total of 226 patients with preimplant erectile function determined by the International Index of Erectile Function (IIEF) questionnaire underwent permanent prostate brachytherapy in two prospective randomized trials between February 2001 and January 2003 for clinical Stage T1c-T2c (2002 American Joint Committee on Cancer) prostate cancer. Of the 226 patients, 132 were potent before treatment and, of those, 128 (97%) completed and returned the IIEF questionnaire after brachytherapy. The median follow-up was 29.1 months. Potency was defined as an IIEF score of ≥13. The clinical, treatment, and dosimetric parameters evaluated included patient age; preimplant IIEF score; clinical T stage; pretreatment prostate-specific antigen level; Gleason score; elapsed time after implantation; preimplant nocturnal erections; body mass index; presence of hypertension or diabetes mellitus; tobacco consumption; the volume of the prostate gland receiving 100%, 150%, and 200% of the prescribed dose (V 100/150/200 ); the dose delivered to 90% of the prostate gland (D 90 ); androgen deprivation therapy; supplemental external beam radiotherapy (EBRT); isotope; prostate volume; planning volume; and radiation dose to the proximal penis. Results: The 3-year actuarial rate of potency preservation was 50.5%. For patients who maintained adequate posttreatment erectile function, the preimplant IIEF score was 29, and in patients with brachytherapy-related ED, the preimplant IIEF score was 25. The median time to the onset of ED was 5.4 months. After brachytherapy, the median IIEF score was 20 in potent patients and 3 in impotent patients. On univariate analysis, the preimplant IIEF score, patient age, presence of nocturnal

  3. Cosmetic Analysis Following Breast-Conserving Surgery and Adjuvant High-Dose-Rate Interstitial Brachytherapy for Early-Stage Breast Cancer: A Prospective Clinical Study

    International Nuclear Information System (INIS)

    Garsa, Adam A.; Ferraro, Daniel J.; DeWees, Todd; Margenthaler, Julie A.; Naughton, Michael; Aft, Rebecca; Gillanders, William E.; Eberlein, Timothy; Matesa, Melissa A.; Zoberi, Imran

    2013-01-01

    Purpose: To prospectively evaluate cosmetic outcomes in women treated with accelerated partial breast irradiation using high-dose-rate interstitial brachytherapy for early-stage breast cancer. Methods and Materials: Between 2004 and 2008, 151 patients with early-stage breast cancer were enrolled in a phase 2 prospective clinical trial. Eligible patients had stage Tis-T2 tumors of ≤3 cm that were excised with negative margins and with no nodal involvement. Patients received 3.4 Gy twice daily to a total dose of 34 Gy. Both the patients and the treating radiation oncologist qualitatively rated cosmesis as excellent, good, fair, or poor over time and ascribed a cause for changes in cosmesis. Cosmetic outcome was evaluated quantitatively by percentage of breast retraction assessment (pBRA). Patients also reported their satisfaction with treatment over time. Results: Median follow-up was 55 months. The rates of excellent-to-good cosmesis reported by patients and the treating radiation oncologist were 92% and 97% pretreatment, 91% and 97% at 3 to 4 months' follow-up, 87% and 94% at 2 years, and 92% and 94% at 3 years, respectively. Breast infection and adjuvant chemotherapy were independent predictors of a fair-to-poor cosmetic outcome at 3 years. Compared to pretreatment pBRA (7.35), there was no significant change in pBRA over time. The volume receiving more than 150 Gy (V150) was the only significant predictor of pBRA. The majority of patients (86.6%) were completely satisfied with their treatment. Conclusions: Patients and the treating physician reported a high rate of excellent-to-good cosmetic outcomes at all follow-up time points. Acute breast infection and chemotherapy were associated with worse cosmetic outcomes. Multicatheter interstitial brachytherapy does not significantly change breast size as measured by pBRA

  4. Cosmetic Analysis Following Breast-Conserving Surgery and Adjuvant High-Dose-Rate Interstitial Brachytherapy for Early-Stage Breast Cancer: A Prospective Clinical Study

    Energy Technology Data Exchange (ETDEWEB)

    Garsa, Adam A.; Ferraro, Daniel J.; DeWees, Todd [Department of Radiation Oncology, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Margenthaler, Julie A. [Department of Surgery, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Naughton, Michael [Department of Medicine, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Aft, Rebecca [Department of Surgery, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Department of Surgery, John Cochran Veterans Hospital, St. Louis, Missouri (United States); Gillanders, William E.; Eberlein, Timothy [Department of Surgery, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Matesa, Melissa A. [Department of Radiation Oncology, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Zoberi, Imran, E-mail: izoberi@radonc.wustl.edu [Department of Radiation Oncology, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States)

    2013-03-15

    Purpose: To prospectively evaluate cosmetic outcomes in women treated with accelerated partial breast irradiation using high-dose-rate interstitial brachytherapy for early-stage breast cancer. Methods and Materials: Between 2004 and 2008, 151 patients with early-stage breast cancer were enrolled in a phase 2 prospective clinical trial. Eligible patients had stage Tis-T2 tumors of ≤3 cm that were excised with negative margins and with no nodal involvement. Patients received 3.4 Gy twice daily to a total dose of 34 Gy. Both the patients and the treating radiation oncologist qualitatively rated cosmesis as excellent, good, fair, or poor over time and ascribed a cause for changes in cosmesis. Cosmetic outcome was evaluated quantitatively by percentage of breast retraction assessment (pBRA). Patients also reported their satisfaction with treatment over time. Results: Median follow-up was 55 months. The rates of excellent-to-good cosmesis reported by patients and the treating radiation oncologist were 92% and 97% pretreatment, 91% and 97% at 3 to 4 months' follow-up, 87% and 94% at 2 years, and 92% and 94% at 3 years, respectively. Breast infection and adjuvant chemotherapy were independent predictors of a fair-to-poor cosmetic outcome at 3 years. Compared to pretreatment pBRA (7.35), there was no significant change in pBRA over time. The volume receiving more than 150 Gy (V150) was the only significant predictor of pBRA. The majority of patients (86.6%) were completely satisfied with their treatment. Conclusions: Patients and the treating physician reported a high rate of excellent-to-good cosmetic outcomes at all follow-up time points. Acute breast infection and chemotherapy were associated with worse cosmetic outcomes. Multicatheter interstitial brachytherapy does not significantly change breast size as measured by pBRA.

  5. Electric rate shock and the future of utility construction

    International Nuclear Information System (INIS)

    Nogee, A.J.

    1985-01-01

    How state regulators spread the costs of overbudget and, in some cases, unneeded new power plants looms as a major political and economic issue directly affecting more than a third of the nation's households and businesses. Today's local battles over rate shock have an even greater national significance because they will shape investment incentives for decades to come. In addition to mismanaged nuclear projects, most nuclear and coal plants being finished today represent excess generating capacity. Utility reserve margins averaged 34% last year instead of the 15-20% above peak demand that analysts agree is desirable. State regulators are increasingly refusing to allow utilities to include new plants in the rate base, and utilities are responding with warnings about future shortages. They may also try to reform or repeal the Holding Company Act. Utility critics point to alternatives to central plant construction with cogeneration and small power generation. 2 figures

  6. Accelerated partial breast irradiation: An analysis of variables associated with late toxicity and long-term cosmetic outcome after high-dose-rate interstitial brachytherapy

    International Nuclear Information System (INIS)

    Wazer, David E.; Kaufman, Seth; Cuttino, Laurie; Di Petrillo, Thomas; Arthur, Douglas W.

    2006-01-01

    Purpose: To perform a detailed analysis of variables associated with late tissue effects of high-dose-rate (HDR) interstitial brachytherapy accelerated partial breast irradiation (APBI) in a large cohort of patients with prolonged follow-up. Methods and Materials: Beginning in 1995, 75 women with Stage I/II breast cancer were enrolled in identical institutional trials evaluating APBI as monotherapy after lumpectomy. Patients eligible included those with T1-2, N0-1 (≤3 nodes positive), M0 tumors of nonlobular histology with negative surgical margins, no extracapsular nodal extension, and negative results on postexcision mammogram. All patients underwent surgical excision and postoperative irradiation with HDR interstitial brachytherapy. The planning target volume was defined as the excision cavity plus a 2-cm margin. Treatment was delivered with a high-activity Ir-192 source at 3.4 Gy per fraction twice daily for 5 days to a total dose of 34 Gy. Dosimetric analyses were performed with three-dimensional postimplant dose and volume reconstructions. All patients were evaluated at 3-6-month intervals and assessed with a standardized cosmetic rating scale and according to Radiation Therapy Oncology Group late normal tissue toxicity scoring criteria. Clinical and therapy-related features were analyzed for their relationship to cosmetic outcome and toxicity rating. Clinical features analyzed included age, volume of resection, history of diabetes or hypertension, extent of axillary surgery, and systemic therapies. Therapy-related features analyzed included volume of tissue encompassed by the 100%, 150%, and 200% isodose lines (V100, V150, and V200, respectively), the dose homogeneity index (DHI), number of source dwell positions, and planar separation. Results: The median follow-up of all patients was 73 months (range, 43-118 months). The cosmetic outcome at last follow-up was rated as excellent, good, and fair/poor in 67%, 24%, and 9% of patients, respectively

  7. Dosimetric characterization of low dose rate Iridium 192 wires used in interstitial brachytherapy, produced by Brachytherapy Sources Laboratory the CTRS/IPEN/CNEN-SP, Brazil

    International Nuclear Information System (INIS)

    Silva, Marco Antonio da

    2003-01-01

    In this work they were some dosimetric parameters established by the dosimetry protocol AAPM TG-43 for the thread of 192 Ir with the purpose of complementing the dosimetric specifications of an original source produced at the country. For so much quantities such as the constant of dose rate, A , function of radial dose, g(r), and anisotropy function, F(r,θ), they were experimentally determined and the geometry function, G(r,θ), it was calculated. Measurements with TLD of LiF, with dimensions of 1 mm X 1 mm X 1 mm, was made in a phantom made of 5 plates of solid water RW3 material with dimensions of 300 mm X 300 mm X 10 mm, where it was obtained values of dose rate for some radial distances of the source, between 10 and 100 mm, to for an angle of 90 deg, for g(r), and also for other angles between 0 deg and 180 deg for F(r,θ). Threads of 192 Ir were studied in the lengths of 10 mm, 20 mm, 30 mm, 50 mm and 100 mm. The stored energy on the thermoluminescent dosimeters was integrated by means of a TLD reader Harshaw 2000 meantime into a cycle of thermal treatment to which the thermoluminescent dosimeters was submitted being, 400 C in an interval of time of 1 hour proceeded immediately for more 2 hours to 105 C, after this treatment the thermoluminescent dosimeters was irradiated; even so, before the reading the detectors was still warm to 105 deg C for 10 minutes. The constant of dose rate for the threads of 192 Ir of 10 mm, 20 mm, 30 mm, 50 mm and 100 mm are (1,076 =- 3,7%); (0,931 =- 3,7%); (0,714 =- 3,7%); (0,589 =-3,7%) and (0,271 =- 3,7%) cGyh -1 U -1 , respectively (1U = unit of kerma intensity in the air = 1mGy m 2 h -1 = 1cGy cm 2 h -1 ). The results obtained for g(r) and F(r,θ) have uncertainties of (=- 4,5%) and they are compared with values obtained by Monte Carlo simulation and also for other values presented in the literature. (author)

  8. SU-F-T-09: In Phantom Full-Implant Validation of Plastic Scintillation Detectors for in Vivo Dosimetry During Low Dose Rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Therriault-Proulx, F; Bruno, T; Beddar, S [UT MD Anderson Cancer Center, Houston, TX (United States); Beaulieu, L [CHU de Quebec, Quebec, QC, CA (Canada)

    2016-06-15

    Purpose: To validate in a water phantom the use of plastic scintillation detectors to measure dose to the urethra and the rectal wall during a clinically realistic low dose rate (LDR) brachytherapy implant. Methods: A template was designed to replicate a clinically realistic LDR brachytherapy prostate implant inside a water phantom. Twenty-two catheters were inserted, including one mimicking the urethra and another the rectal wall. The needles inserted in the remaining 20 catheters were composed of thin-walled nylon tubes in which I-125 radioactive seeds (Air Kerma Strengths of (0.328±0.020)U) were abutted together with plastic spacers to replicate a typical loading. A plastic scintillation detector (PSD) with a 5-mm long × 1-mm diameter sensitive element was first placed inside the urethra and 1-second measurements were performed for 60s after each needle implant. Measurements were also performed at multiple positions along the urethra once all the needles were inserted. The procedure was then repeated with the PSD placed at the rectal wall. Results: Individual dose-rates ranging from 0.07µGy/s to 1.5µGy/s were measured after each needle implant. The average absolute relative differences were (6.2±3.6)% and (6.9±6.5)% to the values calculated with the TG-43 formalism, for the urethra and rectal wall respectively. These results are within expectations from the error uncertainty budget once accounting for uncertainties in seeds’ strength and positioning. Interestingly, the PSD allowed for unplanned error detection as the study was performed. Finally, the measured dose after the full implant at different positions along the mimicked organs at risk were in agreement with TG-43 values for all of the positions tested. Conclusion: Plastic scintillation detectors could be used as in vivo detectors for LDR brachytherapy as they would provide accurate dose information after each needle implant as well as along the organs at risk at the end of the implant.

  9. SU-F-J-157: Effect of Contouring Uncertainty in Post Implant Dosimetry of Low-Dose-Rate Prostate Permanent Seed Brachytherapy

    International Nuclear Information System (INIS)

    Mashouf, S; Merino, T; Ravi, A; Morton, G; Song, W; Safigholi, H; Soliman, A

    2016-01-01

    Purpose: There is strong evidence relating post-implant dosimetry for low-dose-rate (LDR) prostate seed brachytherapy to local control rates. The delineation of the prostate on CT images, however, represents a challenge due to the lack of soft tissue contrast in order to identify the prostate borders. This study aims at quantifying the sensitivity of clinically relevant dosimetric parameters to uncertainty in the contouring of prostate. Methods: CT images, post-op plans and contours of a cohort of patients (n=43) (low risk=55.8%, intermediate risk=39.5%, high risk=4.7%), who had received prostate seed brachytherapy, were imported into MIM Symphony treatment planning system. The prostate contours in post-implant CT images were expanded/contracted uniformly for margins of ±1.00 mm, ±2.00 mm, ±3.00 mm, ±4.00 mm and ±5.00 mm. The values for V100 and D90 were extracted from Dose Volume Histograms for each contour and compared. Results: Significant changes were observed in the values of D90 and V100 as well as the number of suboptimal plans for expansion or contraction margins of only few millimeters. Evaluation of coverage based on D90 was found to be less sensitive to expansion errors compared to V100. D90 led to a lower number of implants incorrectly identified with insufficient coverage for expanded contours which increases the accuracy of post-implant QA using CT images compared to V100. Conclusion: In order to establish a successful post implant QA for LDR prostate seed brachytherapy, it is necessary to identify the low and high thresholds of important dose metrics of the target volume such as D90 and V100. Since these parameters are sensitive to target volume definition, accurate identification of prostate borders would help to improve accuracy and predictive value of the post-implant QA process. In this respect, use of imaging modalities such as MRI where prostate is well delineated should prove useful.

  10. Comparison of one and two low dose rate brachytherapy insertions in the treatment of stage IIB cervix cancer with radiation therapy alone

    International Nuclear Information System (INIS)

    Ferrigno, Robson; Faria, S.L.C.O.

    1996-01-01

    Purpose/Objective: To compare one and two intracavitary brachytherapy with low dose rate in the management of stage IIB cervix cancer through a prospective and randomized trial. Materials and Methods: From September 1989 to December 1992, 81 patients with stage IIB cervix cancer were randomized in two arms according to the number of intracavitary brachytherapy insertion to be realized. Of these, 34 were treated by two intracavitary insertions (group A) and 47 by one insertion (group B). The external beam radiotherapy (EBRT) was realized through a Cobalt unit at whole pelvis with total dose of 40Gy in 20 fractions of 2,0Gy, in box arrangement, followed by parametrial complementation of 10Gy. The brachytherapy was realized right after the end of EBRT. The patients from group A were underwent to two insertions of 25Gy, calculated at point A, defined by the Manchester system. The interval between each insertions was 2 weeks. The patients from group B were underwent to one insertion of 40 Gy at point A. The average dose rate was 60cGy per hour at point A. Results: With the follow up ranging from 36 to 75 months and medium of 55 months, the disease free survival of the patients from group A was not statistically different of those from group B, 70,6% and 72,3% respectively (p=0,711). Local recurrence occurred in four patients from group A (11,7%) and in eight from group B (17%). Distant metastasis occurred in one patient from group A (2,9%) and in two from group B (4,2%). Three patients from group A (8,8%) and three from group B (6,4%) were lost to follow up and considered as dead. The causes of death among patients from group A were progression of local disease in four, distant metastasis in one, complicated diabetes mellitus in one and actinic intestinal complications in other one. The cause of deaths among patients from group B were progression of local disease in eight and distant metastasis in two. The grade I and II rectal complications rate was 5,9% and 6,3% at

  11. BrachyView: Proof-of-principle of a novel in-body gamma camera for low dose-rate prostate brachytherapy

    International Nuclear Information System (INIS)

    Petasecca, M.; Loo, K. J.; Safavi-Naeini, M.; Han, Z.; Metcalfe, P. E.; Lerch, M. L. F.; Qi, Y.; Rosenfeld, A. B.; Meikle, S.; Pospisil, S.; Jakubek, J.; Bucci, J. A.; Zaider, M.

    2013-01-01

    Purpose: The conformity of the achieved dose distribution to the treatment plan strongly correlates with the accuracy of seed implantation in a prostate brachytherapy treatment procedure. Incorrect seed placement leads to both short and long term complications, including urethral and rectal toxicity. The authors present BrachyView, a novel concept of a fast intraoperative treatment planning system, to provide real-time seed placement information based on in-body gamma camera data. BrachyView combines the high spatial resolution of a pixellated silicon detector (Medipix2) with the volumetric information acquired by a transrectal ultrasound (TRUS). The two systems will be embedded in the same probe so as to provide anatomically correct seed positions for intraoperative planning and postimplant dosimetry. Dosimetric calculations are based on the TG-43 method using the real position of the seeds. The purpose of this paper is to demonstrate the feasibility of BrachyView using the Medipix2 pixel detector and a pinhole collimator to reconstruct the real-time 3D position of low dose-rate brachytherapy seeds in a phantom. Methods: BrachyView incorporates three Medipix2 detectors coupled to a multipinhole collimator. Three-dimensionally triangulated seed positions from multiple planar images are used to determine the seed placement in a PMMA prostate phantom in real time. MATLAB codes were used to test the reconstruction method and to optimize the device geometry. Results: The results presented in this paper show a 3D position reconstruction accuracy of the seed in the range of 0.5–3 mm for a 10–60 mm seed-to-detector distance interval (Z direction), respectively. The BrachyView system also demonstrates a spatial resolution of 0.25 mm in the XY plane for sources at 10 mm distance from Medipix2 detector plane, comparable to the theoretical value calculated for an equivalent gamma camera arrangement. The authors successfully demonstrated the capability of BrachyView for

  12. BrachyView: proof-of-principle of a novel in-body gamma camera for low dose-rate prostate brachytherapy.

    Science.gov (United States)

    Petasecca, M; Loo, K J; Safavi-Naeini, M; Han, Z; Metcalfe, P E; Meikle, S; Pospisil, S; Jakubek, J; Bucci, J A; Zaider, M; Lerch, M L F; Qi, Y; Rosenfeld, A B

    2013-04-01

    The conformity of the achieved dose distribution to the treatment plan strongly correlates with the accuracy of seed implantation in a prostate brachytherapy treatment procedure. Incorrect seed placement leads to both short and long term complications, including urethral and rectal toxicity. The authors present BrachyView, a novel concept of a fast intraoperative treatment planning system, to provide real-time seed placement information based on in-body gamma camera data. BrachyView combines the high spatial resolution of a pixellated silicon detector (Medipix2) with the volumetric information acquired by a transrectal ultrasound (TRUS). The two systems will be embedded in the same probe so as to provide anatomically correct seed positions for intraoperative planning and postimplant dosimetry. Dosimetric calculations are based on the TG-43 method using the real position of the seeds. The purpose of this paper is to demonstrate the feasibility of BrachyView using the Medipix2 pixel detector and a pinhole collimator to reconstruct the real-time 3D position of low dose-rate brachytherapy seeds in a phantom. BrachyView incorporates three Medipix2 detectors coupled to a multipinhole collimator. Three-dimensionally triangulated seed positions from multiple planar images are used to determine the seed placement in a PMMA prostate phantom in real time. MATLAB codes were used to test the reconstruction method and to optimize the device geometry. The results presented in this paper show a 3D position reconstruction accuracy of the seed in the range of 0.5-3 mm for a 10-60 mm seed-to-detector distance interval (Z direction), respectively. The BrachyView system also demonstrates a spatial resolution of 0.25 mm in the XY plane for sources at 10 mm distance from Medipix2 detector plane, comparable to the theoretical value calculated for an equivalent gamma camera arrangement. The authors successfully demonstrated the capability of BrachyView for real-time imaging (using a 3 s

  13. Effect of inhomogeneities and source position on dose distribution of nucletron high dose rate Ir-192 brachytherapy source by Monte Carlo simulation

    Directory of Open Access Journals (Sweden)

    Chandola R

    2010-01-01

    Full Text Available Background: The presence of least dense dry air and highly dense cortical bone in the path of radiation and the position of source, near or far from the surface of patient, affects the exact dose delivery like in breast brachytherapy. Aim: This study aims to find out the dose difference in the presence of inhomogenieties like cortical bone and dry air as well as to find out difference of dose due to position of source in water phantom of high dose rate (HDR 192 Ir nucletron microselectron v2 (mHDRv2 brachytherapy source using Monte Carlo (MC simulation EGSnrc code, so that the results could be used in Treatment Planning System (TPS for more precise brachytherapy treatment. Settings and Design: The settings and design are done using different software of the computer. Methods and Materials: For this study, the said source, water phantom of volume 30 x 30 x 30 cm 3 , inhomogeneities each of volume 1 x 2 x 2 cm 3 with their position, water of water phantom and position of source are modeled using three-dimensional MC EGSnrc code. Statistical Analysis Used: Mean and probability are used for results and discussion. Results : The % relative dose difference is calculated here as 5.5 to 6.5% higher and 4.5 to 5% lower in the presence of air and cortical bone respectively at transverse axis of the source, which may be due to difference of linear attenuation coefficients of the inhomogeneities. However, when the source was positioned at 1 cm distance from the surface of water phantom, the near points between 1 to 2 cm and 3 to 8 cm. from the source, at its transverse axis, were 2 to 3.5% and 4 to 16% underdose to the dose when the source was positioned at mid-point of water phantom. This may be due to lack of back scatter material when the source was positioned very near to the surface of said water phantom and overlap of the additional cause of missing scatter component with the primary dose for near points from the source. These results were found in

  14. Development and implementation of a remote audit tool for high dose rate (HDR) Ir-192 brachytherapy using optically stimulated luminescence dosimetry

    International Nuclear Information System (INIS)

    Casey, Kevin E.; Kry, Stephen F.; Howell, Rebecca M.; Followill, David; Alvarez, Paola; Lawyer, Ann

    2013-01-01

    Purpose: The aim of this work was to create a mailable phantom with measurement accuracy suitable for Radiological Physics Center (RPC) audits of high dose-rate (HDR) brachytherapy sources at institutions participating in National Cancer Institute-funded cooperative clinical trials. Optically stimulated luminescence dosimeters (OSLDs) were chosen as the dosimeter to be used with the phantom.Methods: The authors designed and built an 8 × 8 × 10 cm 3 prototype phantom that had two slots capable of holding Al 2 O 3 :C OSLDs (nanoDots; Landauer, Glenwood, IL) and a single channel capable of accepting all 192 Ir HDR brachytherapy sources in current clinical use in the United States. The authors irradiated the phantom with Nucletron and Varian 192 Ir HDR sources in order to determine correction factors for linearity with dose and the combined effects of irradiation energy and phantom characteristics. The phantom was then sent to eight institutions which volunteered to perform trial remote audits.Results: The linearity correction factor was k L = (−9.43 × 10 −5 × dose) + 1.009, where dose is in cGy, which differed from that determined by the RPC for the same batch of dosimeters using 60 Co irradiation. Separate block correction factors were determined for current versions of both Nucletron and Varian 192 Ir HDR sources and these vendor-specific correction factors differed by almost 2.6%. For the Nucletron source, the correction factor was 1.026 [95% confidence interval (CI) = 1.023–1.028], and for the Varian source, it was 1.000 (95% CI = 0.995–1.005). Variations in lateral source positioning up to 0.8 mm and distal/proximal source positioning up to 10 mm had minimal effect on dose measurement accuracy. The overall dose measurement uncertainty of the system was estimated to be 2.4% and 2.5% for the Nucletron and Varian sources, respectively (95% CI). This uncertainty was sufficient to establish a ±5% acceptance criterion for source strength audits under a

  15. Method of localization and implantation of the lumpectomy site for high dose rate brachytherapy after conservative surgery for T1 and T2 breast cancer

    International Nuclear Information System (INIS)

    Perera, F.; Chisela, F.; Engel, J.; Venkatesan, V.

    1995-01-01

    Purpose: This article describes our technique of localization and implantation of the lumpectomy site of patients with T1 and T2 breast cancer. Our method was developed as part of our Phase I/II pilot study of high dose rate (HDR) brachytherapy alone after conservative surgery for early breast cancer. Methods and Materials: In March 1992, we started a pilot study of HDR brachytherapy to the lumpectomy site as the sole radiotherapy after conservative surgery for clinical T1 or T2 invasive breast cancer. Initially, the protocol required intraoperative placement of the interstitial needles at the time of definitive surgery to the breast. The protocol was then generalized to allow the implantation of the lumpectomy site after definitive surgery to the breast, either at the time of subsequent axillary nodal dissection or postoperatively. To date, five patients have been implanted intraoperatively at the time of definitive breast surgery. Twelve patients were implanted after definitive breast surgery, with 7 patients being done at the time of axillary nodal dissection and 5 patients postoperatively. We devised a method of accurately localizing and implanting the lumpectomy site after definitive breast surgery. The method relies on the previous placement of surgical clips by the referring surgeon to mark the lumpectomy site. For each patient, a breast mold is made with radio-opaque angiocatheters taped onto the mold in the supero-inferior direction. A planning CT scan is then obtained through the lumpectomy site. The volume of the lumpectomy site, the number of implant planes necessary, and the orientation of the implants are then determined from the CT scan. The angiocatheters provide a reference grid on the CT films to locate the entry and exit points of the interstitial needles on the plastic mold. The entry and exit points for reference needles are then transferred onto the patient's skin enabling implantation of the lumpectomy site. Needle positions with respect to

  16. SU-E-T-383: Can Stereotactic Body Radiotherapy Mimic the Dose Distribution of High-Dose-Rate Tandem and Ovoids/ring Brachytherapy?

    Energy Technology Data Exchange (ETDEWEB)

    Park, S; Demanes, J; Kamrava, M [UCLA School of Medicine, Los Angeles, CA (United States); Scanderbeg, D [UCSD Medical Center, La Jolla, CA (United States)

    2014-06-01

    Purpose: To investigate whether stereotactic body radiotherapy (SBRT) using volumetric modulated arc therapy (VMAT) can mimic the dosimetry of tandem and ovoids/ring brachytherapy. Methods: We selected 5 patients treated with 3D-CT based high-dose rate (HDR) brachytherapy using 4 tandem and ovoid and 1 tandem and ring case. Manual optimization based on the Manchester system followed by graphical optimization (Nucletron Oncentra MasterPlan or Varian BrachyVision) was performed to deliver 6.0 Gy per fraction to a high-risk CTV while maintaining dose to organs at risk (OAR) below the ABS recommendations. For theoretical SBRT plans, CT images and OAR contours from the HDR plans were imported into Eclipse (Varian). The SBRT plan was created to mimic the heterogeneity of HDR plans by using a simultaneous integrated boost technique to match the V100, V150, and V200 isodose volumes from HDR. The OAR Dmax from HDR was used to define the OAR dose constraints for SBRT. Target coverage, dose spill-out, and OAR doses (D0.1cc, D1cc, and D2cc) between the HDR and SBRT plans were compared for significance using a two-tail paired ttest. Results: The mean isodose volumes for HDR vs. SBRT were 29.4 cc vs. 29.0 cc (V200, p = 0.674), 49.2 cc vs. 56.3 cc (V150, p = 0.017), 95.4 cc vs. 127.7 cc (V100, p = 0.001), and 271.9 cc vs. 581.6 cc (V50, p = 0.001). The D2cc to OAR for HDR vs. SBRT was 71.6% vs. 96.2% (bladder, p = 0.002), 69.2% vs. 101.7% (rectum, p = 0.0003), and 56.9% vs. 68.6% (sigmoid, p = 0.004). Conclusion: SBRT with VMAT can provide similar dose target coverage (V200), but dose spill-out and doses to OAR were statistically significantly higher than HDR. This study clearly demonstrated that brachytherapy can not be substituted with SBRT in gynecologic cervical cancer treatment.

  17. Bronchial mucosal tolerance following high dose rate endobronchial brachytherapy: clinical and laboratory correlates in late complication assessment of fatal hemoptysis

    International Nuclear Information System (INIS)

    Chen, Y.Y.; McDonald, S.; Nakamura, C.; Philips, A.; Ojomo, Karanita; Hernady, E.; Williams, J. P.; Smudzin, T.; Johnstone, D.; Feins, R.; Speiser, B.L.; Rubin, P.

    1996-01-01

    Purpose: This study reviews treatment related late complications following high dose rate endobronchial brachytherapy (HDR-EB) for primary lung cancers. Radiation dose contribution from HDR-EB treatment alone, or combined HDR-EB and external beam (EBRT) were analyzed in relation to the linear representation of the tracheobronchial anatomy. Results were presented in a dose volume histogram (DVH) analysis for the risk estimate of late complications from HDR-EB. Bronchial mucosal tolerance is estimated from the clinical experience study and histopathologic changes in laboratory animals treated with HDR-EB. Methods: 1.) There were forty one patients with primary lung cancer received HDR-EB as part of the radiation treatment between December 1990 and June 1994. Six of these developed late complications manifested as either fatal hemoptysis or endobronchial deposition of fibrinous material/bronchial stenosis. Treatment planning films were reviewed to map the volume treated with HDR-EB and EBRT along the tracheobronchial segments. DVH was constructed and compared for patients with and without late complications. Other clinical parameters of interest which were analyzed included: dose per fraction, EBRT total dose, HDR total dose, combined EBRT and HDR total dose, number of catheters per treatment, and points of prescriptions for HDR-EB. 2.) Forty four New Zealand White rabbits underwent HDR-EB of the major airway to a treatment length of 2 cm (1 cm above and below the carina) to a single fraction dose of 10 Gy, 30 Gy, or 50 Gy. Histopathologic changes were examined at 7, 14, 28, and 56 days post-treatment and compared with the control rabbits which received no irradiation. Results: 1.) The late complication rate is 14.5% with three patients developing fibrinous deposits/bronchial stenosis and four patients who experienced fatal hemoptysis in a total of six patients. There is a significant difference in DVH of HDR-EB treatment in the tracheobronchial high dose region

  18. Definition study of the project Dosimetry Brachytherapy

    International Nuclear Information System (INIS)

    Bultman, J.

    1989-05-01

    The purpose of the research project Dosimetry Brachytherapy is the standardization of calibration methods and quality control procedures used for Brachytherapy sources. Proposals to develop measurement standards and methods for calibrating these sources are presented. Brachytherapy sources will be calibrated in terms of reference airkerma rate or in terms of absorbed dose in water. Therefore, in this project, special attention will be given to the in-phantom measurement method described by Meertens and the use of re-entrant ionisation chambers as transfer standards. In this report, a workplan and time schedule is included. (author). 19 refs.; 1 fig

  19. The value of systematic contouring of the bowel for treatment plan optimization in image-guided cervical cancer high-dose-rate brachytherapy.

    Science.gov (United States)

    Damato, Antonio L; Buzurovic, Ivan; Bhagwat, Mandar S; Cormack, Robert A; Devlin, Phillip M; Friesen, Scott; Hansen, Jorgen; Lee, Larissa J; Manuel, Matthias M; Cho, Linda P; O'Farrell, Desmond; Viswanathan, Akila N

    To investigate the dose-volume histogram metrics and optimization results of the contoured bowel in cervical cancer brachytherapy. Treatment plans of cervical cancer patients treated with image-guided high dose rate were retrospectively analyzed with institutional review board approval. In addition to the clinical target volume, rectum, bladder, and sigmoid, the bowel was contoured at the time of planning (Group 1) or at the time of this analysis (Group 2). Thirty-two patients treated with 145 insertions were included. Before optimization, mean ± 1 standard deviation overall bowel minimum dose to the most irradiated 2 cm 3 volume of an organ (D 2cc ) was 67.8 Gy α/β3 ± 13.7 Gy α/β3 (Group 1: 72.6 ± 13.2 Gy α/β3 ; Group 2: 57.3 ± 8.0 Gy α/β3 ). Before optimization, one patient in Group 1 presented a bowel D 2cc metric exceeding 100 Gy α/β3 . After optimization, bowel D 2cc mean ± 1 standard deviation was 59.4 ± 6.7 Gy α/β3 (Group 1: 61.4 ± 6.0 Gy α/β3 , p bowel when bowel is present in the pelvis. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  20. Emergências em braquiterapia de alta taxa de dose: manual de conduta Radiology emergencies in high-dose rate brachytherapy: code of practice

    Directory of Open Access Journals (Sweden)

    Paulo José Cecilio

    2001-02-01

    Full Text Available É crescente o uso de alta taxa de dose em braquiterapia para tratamento do câncer. O número de pacientes tratados em relação ao número de equipamentos existentes no Brasil é muito grande, sendo constantes os fatores tempo e pressão na rotina de funcionamento. Por isso, é comum, até mesmo nos grandes serviços, a falta de uma reflexão mais cuidadosa voltada à resolução de situações de emergência. Este trabalho faz uma análise prática das situações de emergência mais freqüentes e propõe um manual de conduta básico quando erros impossibilitam o retorno da fonte radioativa ao cofre, causando possível irradiação adicional à paciente e ao "staff" em unidades remotas de braquiterapia. Sugerem-se treinamentos, cuidados adicionais e controle de qualidade como forma de minimizar doses indesejáveis, bem como atenuar transtornos causados nas situações de emergência.The use of high-dose rate brachytherapy for cancer treatment is increasing and the number of patients treated in Brazil is high, considering the number of existing equipments. However, the small number of equipments is a limiting factor that bring on a lot of pressure on the working routine. For this reason, a reevaluation of emergency procedures is not carried out in most centers. This paper describes the most frequent emergency situations and suggests a code of practice when errors do not allow the return of the radiation source to the shield and result in undesirable radiation exposure to the patient and staff in remote centers for brachytherapy. We suggest training, additional caution measures and quality control in order to minimize undesirable doses.

  1. A Prospective Longitudinal Clinical Trial Evaluating Quality of Life After Breast-Conserving Surgery and High-Dose-Rate Interstitial Brachytherapy for Early-Stage Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Garsa, Adam A.; Ferraro, Daniel J.; DeWees, Todd A. [Department of Radiation Oncology, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Deshields, Teresa L. [Department of Medicine, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Margenthaler, Julie A.; Cyr, Amy E. [Department of Surgery, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Naughton, Michael [Department of Medicine, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Aft, Rebecca [Department of Surgery, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Department of Surgery, John Cochran Veterans Hospital, St. Louis, Missouri (United States); Gillanders, William E.; Eberlein, Timothy [Department of Surgery, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Matesa, Melissa A.; Ochoa, Laura L. [Department of Radiation Oncology, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Zoberi, Imran, E-mail: izoberi@radonc.wustl.edu [Department of Radiation Oncology, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States)

    2013-12-01

    Purpose: To prospectively examine quality of life (QOL) of patients with early stage breast cancer treated with accelerated partial breast irradiation (APBI) using high-dose-rate (HDR) interstitial brachytherapy. Methods and Materials: Between March 2004 and December 2008, 151 patients with early stage breast cancer were enrolled in a phase 2 prospective clinical trial. Eligible patients included those with Tis-T2 tumors measuring ≤3 cm excised with negative surgical margins and with no nodal involvement. Patients received 3.4 Gy twice daily to a total dose of 34 Gy. QOL was measured using European Organization for Research and Treatment of Cancer (EORTC) QLQ-C30, version 3.0, and QLQ-BR23 questionnaires. The QLQ-C30 and QLQ-BR23 questionnaires were evaluated during pretreatment and then at 6 to 8 weeks, 3 to 4 months, 6 to 8 months, and 1 and 2 years after treatment. Results: The median follow-up was 55 months. Breast symptom scores remained stable in the months after treatment, and they significantly improved 6 to 8 months after treatment. Scores for emotional functioning, social functioning, and future perspective showed significant improvement 2 years after treatment. Symptomatic fat necrosis was associated with several changes in QOL, including increased pain, breast symptoms, systemic treatment side effects, dyspnea, and fatigue, as well as decreased role functioning, emotional functioning, and social functioning. Conclusions: HDR multicatheter interstitial brachytherapy was well tolerated, with no significant detrimental effect on measured QOL scales/items through 2 years of follow-up. Compared to pretreatment scores, there was improvement in breast symptoms, emotional functioning, social functioning, and future perspective 2 years after treatment.

  2. SU-E-J-93: Parametrisation of Dose to the Mucosa of the Anterior Rectal Wall in Transrectal Ultrasound Guided High-Dose-Rate Brachytherapy of the Prostate

    Energy Technology Data Exchange (ETDEWEB)

    Aitkenhead, A; Hamlett, L; Wood, D; Choudhury, A [The Christie Hospital NHS Foundation Trust, Manchester, Greater Manchester (United Kingdom)

    2014-06-01

    Purpose: In high-dose-rate (HDR) brachytherapy of the prostate, radiation is delivered from a number of radioactive sources which are inserted via catheter into the target volume. The rectal mucosa also receives dose during the treatment, which may lead to late toxicity effects. To allow possible links between rectal dose and toxicity to be investigated, suitable methods of parametrising the rectal dose are needed. Methods: During treatment of a series of 95 patients, anatomy and catheter locations were monitored by transrectal ultrasound, and target volume positions were contoured on the ultrasound scan by the therapist. The anterior rectal mucosal wall was identified by contouring the transrectal ultrasound balloon within the ultrasound scan. Source positions and dwell times, along with the dose delivered to the patient were computed using the Oncentra Prostate treatment planning system (TPS). Data for the series of patients were exported from the TPS in Dicom format, and a series of parametrisation methods were developed in a Matlab environment to assess the rectal dose. Results: Contours of the anterior rectal mucosa were voxelised within Matlab to allow the dose to the rectal mucosa to be analysed directly from the 3D dose grid. Dose parametrisations based on dose-surface (DSH) and dose-line (DLH) histograms were obtained. Both lateral and longitudinal extents of the mucosal dose were parametrised using dose-line histograms in the relevant directions. Conclusion: We have developed a series of dose parametrisations for quantifying the dose to the rectal mucosa during HDR prostate brachytherapy which are suitable for future studies investigating potential associations between mucosal dose and late toxicity effects. The geometry of the transrectal probe standardises the rectal anatomy, making this treatment technique particularly suited to studies of this nature.

  3. SU-E-J-93: Parametrisation of Dose to the Mucosa of the Anterior Rectal Wall in Transrectal Ultrasound Guided High-Dose-Rate Brachytherapy of the Prostate

    International Nuclear Information System (INIS)

    Aitkenhead, A; Hamlett, L; Wood, D; Choudhury, A

    2014-01-01

    Purpose: In high-dose-rate (HDR) brachytherapy of the prostate, radiation is delivered from a number of radioactive sources which are inserted via catheter into the target volume. The rectal mucosa also receives dose during the treatment, which may lead to late toxicity effects. To allow possible links between rectal dose and toxicity to be investigated, suitable methods of parametrising the rectal dose are needed. Methods: During treatment of a series of 95 patients, anatomy and catheter locations were monitored by transrectal ultrasound, and target volume positions were contoured on the ultrasound scan by the therapist. The anterior rectal mucosal wall was identified by contouring the transrectal ultrasound balloon within the ultrasound scan. Source positions and dwell times, along with the dose delivered to the patient were computed using the Oncentra Prostate treatment planning system (TPS). Data for the series of patients were exported from the TPS in Dicom format, and a series of parametrisation methods were developed in a Matlab environment to assess the rectal dose. Results: Contours of the anterior rectal mucosa were voxelised within Matlab to allow the dose to the rectal mucosa to be analysed directly from the 3D dose grid. Dose parametrisations based on dose-surface (DSH) and dose-line (DLH) histograms were obtained. Both lateral and longitudinal extents of the mucosal dose were parametrised using dose-line histograms in the relevant directions. Conclusion: We have developed a series of dose parametrisations for quantifying the dose to the rectal mucosa during HDR prostate brachytherapy which are suitable for future studies investigating potential associations between mucosal dose and late toxicity effects. The geometry of the transrectal probe standardises the rectal anatomy, making this treatment technique particularly suited to studies of this nature

  4. Determination of Prognostic Factors for Vaginal Mucosal Toxicity Associated With Intravaginal High-Dose Rate Brachytherapy in Patients With Endometrial Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bahng, Agnes Y.; Dagan, Avner [Department of Radiation Oncology, University of Pennsylvania School of Medicine, Philadelphia, PA (United States); Bruner, Deborah W. [University of Pennsylvania School of Nursing, Philadelphia, PA (United States); Lin, Lilie L., E-mail: lin@xrt.upenn.edu [Department of Radiation Oncology, University of Pennsylvania School of Medicine, Philadelphia, PA (United States)

    2012-02-01

    Purpose: The objective of this study was to determine the patient- and treatment-related prognostic factors associated with vaginal toxicity in patients who received intravaginal high dose rate (HDR) brachytherapy alone as adjuvant treatment for endometrial cancer. Secondary goals of this study included a quantitative assessment of optimal dilator use frequency and a crude assessment of clinical predictors for compliant dilator use. Methods and Materials: We retrospectively reviewed the charts of 100 patients with histologically confirmed endometrial cancer who underwent total hysterectomy and bilateral salpingo-oophorectomy with or without lymph node dissection and adjuvant intravaginal brachytherapy between 1995 and 2009 at the Hospital of University of Pennsylvania. The most common treatment regimen used was 21 Gy in three fractions (71 patients). Symptoms of vaginal mucosal toxicity were taken from the history and physical exams noted in the patients' charts and were graded according to the Common Toxicity Criteria for Adverse Events v. 4.02. Results: The incidence of Grade 1 or asymptomatic vaginal toxicity was 33% and Grade 2-3 or symptomatic vaginal toxicity was 14%. Multivariate analysis of age, active length, and dilator use two to three times a week revealed odds ratios of 0.93 (p = 0.013), 3.96 (p = 0.008), and 0.17 (p = 0.032) respectively. Conclusion: Increasing age, vaginal dilator use of at least two to three times a week, and shorter active length were found to be significantly associated with a decreased risk of vaginal stenosis. Future prospective studies are necessary to validate our findings.

  5. Brachytherapy dosimeter with silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Moutinho, L.M., E-mail: moutinho@ua.pt [i3N, Physics Department, University of Aveiro (Portugal); Castro, I.F.C. [i3N, Physics Department, University of Aveiro (Portugal); Peralta, L. [Faculdade de Ciências da Universidade de Lisboa (Portugal); Laboratório de Instrumentação e Física Experimental de Partículas (LIP), Lisboa (Portugal); Abreu, M.C. [Laboratório de Instrumentação e Física Experimental de Partículas (LIP), Lisboa (Portugal); Veloso, J.F.C.A. [i3N, Physics Department, University of Aveiro (Portugal)

    2015-07-01

    In-vivo and in-situ measurement of the radiation dose administered during brachytherapy faces several technical challenges, requiring a very compact, tissue-equivalent, linear and highly sensitive dosimeter, particularly in low-dose rate brachytherapy procedures, which use radioactive seeds with low energy and low dose deposition rate. In this work we present a scintillating optical fiber dosimeter composed of a flexible sensitive probe and a dedicated electronic readout system based on silicon photomultiplier photodetection, capable of operating both in pulse and current modes. The performance of the scintillating fiber optic dosimeter was evaluated in low energy regimes, using an X-ray tube operating at voltages of 40–50 kV and currents below 1 mA, to assess minimum dose response of the scintillating fiber. The dosimeter shows a linear response with dose and is capable of detecting mGy dose variations like an ionization chamber. Besides fulfilling all the requirements for a dosimeter in brachytherapy, the high sensitivity of this device makes it a suitable candidate for application in low-dose rate brachytherapy. According to Peralta and Rego [1], the BCF-10 and BCF-60 scintillating optical fibers used in dosimetry exhibit high variations in their sensitivity for photon beams in the 25–100 kVp energy range. Energy linearity for energies below 50 keV needs to be further investigated, using monochromatic X-ray photons.

  6. Comprehensive brachytherapy physical and clinical aspects

    CERN Document Server

    Baltas, Dimos; Meigooni, Ali S; Hoskin, Peter J

    2013-01-01

    Modern brachytherapy is one of the most important oncological treatment modalities requiring an integrated approach that utilizes new technologies, advanced clinical imaging facilities, and a thorough understanding of the radiobiological effects on different tissues, the principles of physics, dosimetry techniques and protocols, and clinical expertise. A complete overview of the field, Comprehensive Brachytherapy: Physical and Clinical Aspects is a landmark publication, presenting a detailed account of the underlying physics, design, and implementation of the techniques, along with practical guidance for practitioners. Bridging the gap between research and application, this single source brings together the technological basis, radiation dosimetry, quality assurance, and fundamentals of brachytherapy. In addition, it presents discussion of the most recent clinical practice in brachytherapy including prostate, gynecology, breast, and other clinical treatment sites. Along with exploring new clinical protocols, ...

  7. SU-E-T-232: Custom High-Dose-Rate Brachytherapy Surface Mold Applicators: The Importance Source to Skin Distance

    International Nuclear Information System (INIS)

    Park, S; Demanes, J; Kamrava, M

    2015-01-01

    Purpose: Surface mold applicators can be customized to fit irregular skin surfaces that are difficult to treat with other radiation therapy techniques. Optimal design of customized HDR skin brachytherapy is not well-established. We evaluated the impact of applicator thickness (source to skin distance) on target dosimetry. Methods: 27 patients had 34 treated sites: scalp 4, face 13, extremity 13, and torso 4. Custom applicators were constructed from 5–15 mm thick thermoplastic bolus molded over the skin lesion. A planar array of plastic brachytherapy catheters spaced 5–10 mm apart was affixed to the bolus. CT simulation was used to contour the target volume and to determine the prescription depth. Inverse planning simulated annealing followed by graphical optimization was used to plan and deliver 40–56 Gy in 8–16 fractions. Target coverage parameters (D90, Dmean, and V100) and dose uniformity (V110–200, D0.1cc, D1cc, and D2cc) were studied according to target depth (<5mm vs. ≥5mm) and applicator thickness (5–10mm vs. ≥10mm). Results: The average prescription depth was 4.2±1.5mm. The average bolus thickness was 9.2±2.4mm. The median CTV volume was 10.0 cc (0.2–212.4 cc). Similar target coverage was achieved with prescription depths of <5mm and ≥5mm (Dmean = 113.8% vs. 112.4% and D90 = 100.2% vs. 98.3%). The <5mm prescription depth plans were more uniform (D0.1cc = 131.8% vs. 151.8%). Bolus thickness <10mm vs. ≥10mm plans also had similar target coverage (Dmean = 118.2% vs. 110.7% and D90 = 100.1% vs. 99.0%). Applicators ≥10mm thick, however, provide more uniform target dosimetry (D0.1cc = 146.9% vs. 139.5%). Conclusion: Prescription depth is based upon the thickness of the lesion and upon the clinical needs of the patient. Applicators ≥10mm thick provide more dose uniformity than 5–10mm thick applicators. Applicator thickness is an important variable that should be considered during treatment planning to achieve optimal dose uniformity

  8. WE-G-BRB-07: Application of RADPOS in Vivo Dosimetry for QA of High Dose Rate Brachytherapy.

    Science.gov (United States)

    Cherpak, A; Kertzscher, G; Cygler, J

    2012-06-01

    The RADPOS in vivo dosimetry system combines an electromagnetic positioning sensor with MOSFET dosimetry, allowing for simultaneous online measurements of dose and spatial position. In this work, we assess the potential use of RADPOS for measurements of motion and dose during prostate HDR brachytherapy. The RADPOS was positioned in the centre of a thin plastic tube supported by two parallel acrylic plates submerged in water. The detector was calibrated by sending an Ir-192 source into an adjacent tube, to positions ranging from 8.0 to -8.0 cm along the vertical axis in increments of 0.5 cm. The dwell time at each position was 20 s and the change in threshold voltage of the RADPOS dosimeter was recorded for each position. The expected dose for each source position was calculated and compared to RADPOS measurements to obtain a detector calibration coefficient (cGy/mV). The procedure was then repeated sending the Ir-192 source into 5 other tubes, located 1 to 10 cm away from the RADPOS. Source positions, dwell times, and position of the RADPOS detector were the same as for the calibration. The dose for each source position was determined by RADPOS measurements and calibration coefficient and compared to the expected dose. An average calibration coefficient of 0.74±0.11 cGy/mV was calculated for RADPOS measurements of Ir-192 irradiations. The absolute difference between RADPOS values and expected dose for subsequent measurements averaged over all source positions was 0.7±5.4 cGy. In vivo dosimetry can potentially signal errors in catheter placement or numbering before entire dose is delivered. The demonstrated accuracy of RADPOS dose measurements and its ability to simultaneously measure displacement makes it a powerful tool for HDR brachytherapy treatments for prostate cancer, where high dose gradients and movement of the prostate gland can present unique in vivo dosimetry challenges. Financial and technical support has been received from Best Medical Canada and

  9. Clinicopathologic Comparison of High-Dose-Rate Endorectal Brachytherapy versus Conventional Chemoradiotherapy in the Neoadjuvant Setting for Resectable Stages II and III Low Rectal Cancer

    Directory of Open Access Journals (Sweden)

    Jessica A. Smith

    2012-01-01

    Full Text Available Purpose. To assess for differences in clinical, radiologic, and pathologic outcomes between patients with stage II-III rectal adenocarcinoma treated neoadjuvantly with conventional external beam radiotherapy (3D conformal radiotherapy (3DRT or intensity-modulated radiotherapy (IMRT versus high-dose-rate endorectal brachytherapy (EBT. Methods. Patients undergoing neoadjuvant EBT received 4 consecutive daily 6.5 Gy fractions without chemotherapy, while those undergoing 3DRT or IMRT received 28 daily 1.8 Gy fractions with concurrent 5-fluorouracil. Data was collected prospectively for 7 EBT patients and retrospectively for 25 historical 3DRT/IMRT controls. Results. Time to surgery was less for EBT compared to 3DRT and IMRT (P<0.001. There was a trend towards higher rate of pathologic CR for EBT (P=0.06. Rates of margin and lymph node positivity at resection were similar for all groups. Acute toxicity was less for EBT compared to 3DRT and IMRT (P=0.025. Overall and progression-free survival were noninferior for EBT. On MRI, EBT achieved similar complete response rate and reduction in tumor volume as 3DRT and IMRT. Histopathologic comparison showed that EBT resulted in more localized treatment effects and fewer serosal adhesions. Conclusions. EBT offers several practical benefits over conventional radiotherapy techniques and appears to be at least as effective against low rectal cancer as measured by short-term outcomes.

  10. Dosimetry TL 'in vivo' for the quality control in radiotherapy with Co-60 and brachytherapy of low dose rate

    International Nuclear Information System (INIS)

    Velez, G.; Balmaceda, O.; Gutierrez, S.; Ferraris, M.; Bustos, S.

    1998-01-01

    Full text: The dosimetry 'in vivo' is used frequently as a valuable tool for the quality control in radiotherapy. Measurements of the entry and exit doses provide us of information on the precision of the technique or the procedure of used treatment; the measurement of the doses in rectal or bladder in gynecological implants contribute to perfect or to adjust the procedures in brachytherapy. Also systematic errors can be identified in particular situations that allow to optimize the treatment and to minimize errors. A study in the service of Radiotherapy of the San Roque Hospital, was realized for to control the procedures used in the treatment of different cancer therapy. Patients were selected, to which were carried out a routine planning with the system of planning of on line treatment Prowess 3000 that then were controlled with thermoluminescent dosemeters 'in vivo' using the Ceprocor Services. Skin doses were measurement in treatment of breast, pelvis, thorax, head and neck, and doses was measured in cavities of the body as oral cavity, rectal, esophagus, etc., placing the TLD inside special catheters. In the case of doses in skin, the dosimeters was placed in acrylic badges. A very good agreement was found between the measurements 'in vivo' and the plans of the planner. In some cases the control allowed to modify the doses to avoid organs damage for the radiation fields. (author) [es

  11. In vivo Tl dosimetry for the quality control in Radiotherapy with 60 Co and brachytherapy of low dose rate

    International Nuclear Information System (INIS)

    Velez, G.; Bustos, S.; Balmaceda, O.; Gutierrez, S.; Ferraris, M.

    1998-01-01

    In vivo dosimetry is used every time with more frequency as a valuable tool for the quality control in Radiotherapy. The measurements of input and output doses provide us information about the technique accuracy or the treatment procedure used; likewise the dose measurement which rectum or bladder receive in gynecologic implants contribute to the improving and adjusting the procedures in brachytherapy. Besides, it may be identify systematic errors in particular situations which allow to optimize the treatment and to minimize errors. It was realized a study at the Radiotherapy service in San Roque Hospital (Cordoba) to control the procedures used in the treatment of distinct oncologic pathologies. Its were selected patients, which were realized the routine planning with the planning system of computerized treatments Prowess 3000, that later its were controlled with In vivo thermoluminescent dosimetry using the Ceprocor Services (Cordoba). Its were realized dose skin measurements in treatments of mammary gland, pelvis, thorax, head and neck and it were measured doses in body cavities, as oral cavity, rectum, esophagus, etc. arranging the TLD inside special catheters. In the case of dose skin, the dosemeters were arranged in acrylic porta-dosemeters, at pairs, which later they were enveloped and sealed. It was founded a very good agreement among the In vivo measurements and the predicted by the planner. In some cases, the control allows to modify the treatment for to avoid over or sub dosages of the distinct organs affected by the radiation field. (Author)

  12. Study of dosimetric variation due to interfraction organ movement in High Dose Rate Interstital (MUPIT) brachytherapy for gynecologic malignancies

    Science.gov (United States)

    Velmurugan, Thanigaimalai; Sukumar, Prabakar; Krishnappan, Chokkalingam; Boopathy, Raghavendiran

    2010-01-01

    Ten patients with cancer of uterine cervix who underwent interstitial brachytherapy using MUPIT templates were CT scanned (CT1) using which bladder, rectum and CTV were delineated. The treatment plan PCT1 was generated and optimized geometrically on the volume. CT scan (CT2) was repeated before the second fraction of the treatment CTV and critical organs were delineated. The plan (PCT2) was created by reproducing the Plan PCT1 in the CT2 images and compared with PCT1. Bladder, Rectum and CTV percentage volume variation ranges from +28.6% to -34.3%, 38.4% to -14.9% and 8.5% to -15.2% respectively. Maximum dose variation in bladder was +17.1%, in rectum was up to +410% and in CTV was -13.0%. The dose to these structures varies independently with no strong correlation with the volume variation. Hence it is suggested that repeat CT and re-planning is mandatory before second fraction execution.

  13. Acute genitourinary toxicity after high dose rate (HDR) brachytherapy combined with hypofractionated external-beam radiation therapy for localized prostate cancer: Second analysis to determine the correlation between the urethral dose in HDR brachytherapy and the severity of acute genitourinary toxicity

    International Nuclear Information System (INIS)

    Akimoto, Tetsuo; Katoh, Hiroyuki; Noda, Shin-ei; Ito, Kazuto; Yamamoto, Takumi; Kashiwagi, Bunzo; Nakano, Takashi

    2005-01-01

    Purpose: We have been treating localized prostate cancer with high-dose-rate (HDR) brachytherapy combined with hypofractionated external beam radiation therapy (EBRT) at our institution. We recently reported the existence of a correlation between the severity of acute genitourinary (GU) toxicity and the urethral radiation dose in HDR brachytherapy by using different fractionation schema. The purpose of this study was to evaluate the role of the urethral dose in the development of acute GU toxicity more closely than in previous studies. For this purpose, we conducted an analysis of patients who had undergone HDR brachytherapy with a fixed fractionation schema combined with hypofractionated EBRT. Methods and Materials: Among the patients with localized prostate cancer who were treated by 192-iridium HDR brachytherapy combined with hypofractionated EBRT at Gunma University Hospital between August 2000 and November 2004, we analyzed 67 patients who were treated by HDR brachytherapy with the fractionation schema of 9 Gy x two times combined with hypofractionated EBRT. Hypofractionated EBRT was administered at a fraction dose of 3 Gy three times weekly, and a total dose of 51 Gy was delivered to the prostate gland and seminal vesicles using the four-field technique. No elective pelvic irradiation was performed. After the completion of EBRT, all the patients additionally received transrectal ultrasonography-guided HDR brachytherapy. The planning target volume was defined as the prostate gland with a 5-mm margin all around, and the planning was conducted based on computed tomography images. The tumor stage was T1c in 13 patients, T2 in 31 patients, and T3 in 23 patients. The Gleason score was 2-6 in 12 patients, 7 in 34 patients, and 8-10 in 21 patients. Androgen ablation was performed in all the patients. The median follow-up duration was 11 months (range 3-24 months). The toxicities were graded based on the Radiation Therapy Oncology Group and the European Organization

  14. Volume and dose rate dependent (MDR-LDR Ir-192 afterloading interstitial brachytherapy) treatment optimisation, for squamouscell carcinoma of the lip

    International Nuclear Information System (INIS)

    Stas, Nathalie; Goncalves, Julieta; Pinho, Eliana; Trigo, Lurdes; Fernandes, Tome; Vieira, Elio

    1996-01-01

    Introduction: From 1/1/90 to 1/1/95, 53 patients with squamouscell carcinoma of the lip were treated by MDR or LDR Ir-192 afterloading interstitital brachytherapy. We compare the oncological and aesthetical results and sequelae depending on the volume and the dose rate. Material and methods: 53 patients, 41 men and 12 women, median age = 66y; 48 primary tumors (T1 = 26; T2 = 16; T3 = 6; N0 = 47; N1 = 1; M0 = 48) and 5 recurrencies; squamouscell carcinoma (grade 1 =45, g2 =6, g3 =2); clinical extension: buccal comissure=3, check =2, muscular =15, skin =7, lower and upper lip =1. Before radiotherapy, 28 biopsies and 25 excisional surgeries (19 with positive margins, 6 with negative margins) were performed. Brachytherapy was performed alone (dose 60-75 Gy BD85%) or as a boost (dose 10-30 Gy BD85%) associated with external beam (dose 46-50 Gy). MDR or LDR microselectron's afterloading was done after a computerised dosimetry (Paris System): treatment mean time = 30, 98 hours; mean volume = 10,2 cc (T1-T2 8, 61cc); Ir - 192 activity = range 0,7 - 4,792 mCi/cm; reference dose rate 45,6 - 290, 1 cGy/h. Results: 46 patients are alive without cancer, 1 died without responding, 6 died from non oncological diseases; 8 patients had recurrences (5 local, 3 nodal) but are alive. Mean follow-up 30,83 months (range 3-60m), mean DFS = 22,49 m (range 5-57m). Acute secondary effects: 30 radioepithelyties (grade 1 = 7, g2=23, g3=14), and 39 radiomucitis (g1=3; g2=23; g3=13); mean time for complete healing = 21, 66 days. Sequelae: moderate sclerosis of the skin =11, skin retraction = 1, hyperpigmentation2, depigmentation= 10, edema= 6, gingivitis= 7. Aesthetical results: good32; moderate= 18; bad= 2, very bad= 1 (uncontrolled tumor). Conclusions: The sequelae and aesthetical results are closely dependent on the treated volume and the dose rate, less dependent on the total dose, and independent on the Iridium activity. Complete healing time does not influence the late aesthetical results

  15. Combination of high-dose rate brachytherapy and external beam radiotherapy for the treatment of advanced scalp angiosarcoma - case report; Braquiterapia de alta taxa de dose associada a radioterapia externa no tratamento de angiossarcoma extenso do couro cabeludo - relato de caso

    Energy Technology Data Exchange (ETDEWEB)

    Gentil, Andre Cavalcanti; Lima Junior, Carlos Genesio Bezerra [Instituto Nacional do Cancer, Rio de Janeiro, RJ (Brazil). Dept. de Radioterapia]. E-mail: andregentil@hotmail.com; Soboll, Danyel Scheidegger; Novaes, Paulo Eduardo R.S.; Pereira, Adelino Jose; Pellizon, Antonio Carlos Assis [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Centro de Tratamento e Pequisa

    2001-10-01

    The authors report a case of a patient with an extensive angiosarcoma of the scalp that was submitted only to radiotherapy with a combination of orthovoltage roentgentherapy and high-dose rate brachytherapy, using a mould. The clinical and technical features as well as the therapeutic outcome are presented, and the usefulness and peculiarities of high-dose rate brachytherapy for this particular indication is discussed. A comparative analysis of the difficulties and limitations of employing low-dose rate brachytherapy is also presented. The authors concluded that high-dose rate brachytherapy might be an useful, practical and safe option to treat neoplastic lesions of the scalp, and an alternative treatment to electrontherapy. (author)

  16. Fractionated perineal high-dose-rate temporary brachytherapy combined with external beam radiation in the treatment of localized prostate cancer: is lymph node sampling necessary?

    International Nuclear Information System (INIS)

    Gyorgy, Kovacs; Razvan, Galalae

    2003-01-01

    To study the influence of imaging based nodal staging and local dose escalation by a high-dose-rate brachytherapy (HDR-BT) boost in the treatment of locally confined prostate cancer in terms of prostate specific antigen (PSA) recurrence-free survival (biochemical non-evidence of disease (bNED)), treatment toxicity and prognostic variables. The prospectively recorded files of 144 men aged in a median of 68 years with a mean follow-up of 8 years (60-171 months) receiving curatively intended, transrectal ultrasound guided high-dose-rate 192-iridium-brachytherapy (HDR-BT) combined with external beam radiation therapy (EBRT) for locally confined prostate cancer were analyzed. T-stages were defined by digital rectal investigation and transrectal sonography (TRUS), nodal staging was performed with computed tomography (CT)/magnetic resonance imaging (MRI) (UICC/AJCR 1992). Twenty-nine patients (20.1%) had T1b-T2a tumors, and 115 patients had T2b-T3 tumors. Median initial PSA (iPSA) was 12.15 ng mL -1 (mean 25.61 ng mL -1 ). The total planned dose applied by external beam radiation was 50 Gy in the pelvis, and 40 Gy in the prostate by in-field-dose modification by individual compensators. The perineal, TRUS guided HDR-BT was delivered in two fractions of 15 Gy each. The target of BT boost was the peripheral zone of the prostate. The overall survival was 71.5%o and that of the disease free survival 82.6%. Freedom from distant metastases in T3 stage was 91.3%, whereas for G3 lesions, it was 88.23%. The bNED rate was 72.9%. Regarding treatment related late toxicity according to the EORTC/RTOG score, we observed grade 1, 2, 3 proctitis in 9.72%, 6.94%, 4.10% as well as grade 1, 2, 3 cystitis in 12.5%, 4.16%2.08%, respectively. Grade 4 and 5 proctitis or cystitis were not registered. The minimum 5-year and mean 8-year results confirm that local dose escalation by TRUS guided perineal HDR-BT and complementary external beam radiation of the pelvic lymphatics has curative potential

  17. Workflow efficiency for the treatment planning process in CT-guided high-dose-rate brachytherapy for cervical cancer.

    Science.gov (United States)

    Michaud, Anthony L; Benedict, Stanley; Montemayor, Eliseo; Hunt, Jon Paul; Wright, Cari; Mathai, Mathew; Mayadev, Jyoti S

    2016-01-01

    To investigate process efficiency, we present a prospective investigation of the treatment planning phase of image-guided brachytherapy (BT) for cervical cancer using a specific checklist. From October 2012 to January 2014, 76 BT procedures were consecutively performed. Prospective data on the CT-based treatment planning process was collected using a specific checklist which details the following steps: (1) dosimetry planning, (2) physician review start, (3) physician review time, (4) dosimetry processing, (5) physics review start, (6) physics review, and (7) procedural pause. Variables examined included the use of a pre-BT MRI, clinic duty conflicts, resident teaching, and the use of specific BT planners. Analysis was performed using descriptive statistics, t-test, and analysis of variance. Seventy-five prospectively gathered checklists comprised this analysis. The mean time for treatment planning was 95 minutes (med 94, std 18). The mean intervals in the above steps were (1) = 42, (2) = 5, (3) = 19, (4) = 10, (5) = 6, (6) = 13, and (7) = 26 minutes. There was no statistical difference in patients who had a pre-BT MRI. Resident teaching did not influence time, p = 0.17. Treatment planning time was decreased with a specific planner, p = 0.0015. A skillful team approach is required for treatment planning efficiency in image-guided BT. We have found that the specific BT planners can have a significant effect on the overall planning efficiency. We continue to examine clinical and workflow-related factors that will enhance our safety and workflow process with BT. Published by Elsevier Inc.

  18. Dosimetric evaluation of PLATO and Oncentra treatment planning systems for High Dose Rate (HDR) brachytherapy gynecological treatments

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Hardev; De La Fuente Herman, Tania; Showalter, Barry; Thompson, Spencer J.; Syzek, Elizabeth J.; Herman, Terence; Ahmad, Salahuddin [Department of Radiation Oncology, Peggy and Charles Stephenson Oklahoma Cancer Center, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104 (United States)

    2012-10-23

    This study compares the dosimetric differences in HDR brachytherapy treatment plans calculated with Nucletron's PLATO and Oncentra MasterPlan treatment planning systems (TPS). Ten patients (1 T1b, 1 T2a, 6 T2b, 2 T4) having cervical carcinoma, median age of 43.5 years (range, 34-79 years) treated with tandem and ring applicator in our institution were selected retrospectively for this study. For both Plato and Oncentra TPS, the same orthogonal films anterior-posterior (AP) and lateral were used to manually draw the prescription and anatomical points using definitions from the Manchester system and recommendations from the ICRU report 38. Data input for PLATO was done using a digitizer and Epson Expression 10000XL scanner was used for Oncentra where the points were selected on the images in the screen. The prescription doses for these patients were 30 Gy to points right A (RA) and left A (LA) delivered in 5 fractions with Ir-192 HDR source. Two arrangements: one dwell position and two dwell positions on the tandem were used for dose calculation. The doses to the patient points right B (RB) and left B (LB), and to the organs at risk (OAR), bladder and rectum for each patient were calculated. The mean dose and the mean percentage difference in dose calculated by the two treatment planning systems were compared. Paired t-tests were used for statistical analysis. No significant differences in mean RB, LB, bladder and rectum doses were found with p-values > 0.14. The mean percent difference of doses in RB, LB, bladder and rectum are found to be less than 2.2%, 1.8%, 1.3% and 2.2%, respectively. Dose calculations based on the two different treatment planning systems were found to be consistent and the treatment plans can be made with either system in our department without any concern.

  19. Health-Related Quality of Life After Single-Fraction High-Dose-Rate Brachytherapy and Hypofractionated External Beam Radiotherapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Morton, Gerard C.; Loblaw, D. Andrew; Chung, Hans; Tsang, Gail; Sankreacha, Raxa; Deabreu, Andrea; Zhang Liying; Mamedov, Alexandre; Cheung, Patrick; Batchelar, Deidre; Danjoux, Cyril; Szumacher, Ewa

    2011-01-01

    Purpose: To investigate the change in health-related quality of life for men after high-dose-rate brachytherapy and external beam radiotherapy for prostate cancer and the factors associated with this change. Methods and Materials: Eligible patients had clinically localized intermediate-risk prostate cancer. The patients received high-dose-rate brachytherapy as a single 15-Gy implant, followed by external beam radiotherapy to 37.5 Gy in 15 fractions. The patients were monitored prospectively for toxicity (Common Terminology Criteria for Adverse Events, version 3.0) and health-related quality of life (Expanded Prostate Cancer Index Composite [EPIC]). The proportion of patients developing a clinically significant difference in the EPIC domain score (minimally important difference of >0.5 standard deviation) was determined and correlated with the baseline clinical and dosimetric factors. The study accrued 125 patients, with a median follow-up of 24 months. Results: By 24 months, 23% had Grade 2 urinary toxicity and only 5% had Grade 2 bowel toxicity, with no Grade 3 toxicity. The proportion of patients reporting a significant decrease in EPIC urinary, bowel, sexual, and hormonal domain scores was 53%, 51%, 45%, and 40% at 12 months and 57%, 65%, 51%, and 30% at 24 months, respectively. The proportion with a >1 standard deviation decrease in the EPIC urinary, bowel, sexual, and hormonal domain scores was 38%, 36%, 24%, and 20% at 12 months and 46%, 48%, 19%, and 8% at 24 months, respectively. On multivariate analysis, the dose to 10% of the urethra was associated with a decreasing EPIC urinary domain score (p = .0089) and, less strongly (p = .0312) with a decreasing hormonal domain score. No association was found between the prostate volume, bladder dose, or high-dose volume and urinary health-related quality of life. A high baseline International Index of Erectile Function score was associated (p = .0019) with a decreasing sexual domain score. The optimal maximal dose

  20. Monte Carlo simulation of gynecologic brachytherapy treatment of high rate considering the heterogeneity; Simulacion Monte Carlo de un tratamiento de braquiterapia ginecologica de alta tasa teniendo en cuenta las heterogeneidades

    Energy Technology Data Exchange (ETDEWEB)

    Berenguer Serrano, R.; Rivera Jimenez, M.; Nunez Quintanilla, A. T.; Vara Olivas, V. de la; Gutierrez Perez, M.; Sabater Martin, S.

    2011-07-01

    The objective of this study was to compare the dosimetric distribution of gynecological brachytherapy treatment with high dose rate Ir-192 source as does a conventional planner versus dosimetric distribution obtained by Monte Carlo simulation taking into account (addition to the geometry of the source), gynecologic vaginal applicator (tube and vaginal cylinder or dome) and the anatomy of the patient. In particular we assessed the effect of the presence of iodinated contrast in the bladder of the patient.

  1. Long duration mild temperature hyperthermia and brachytherapy.

    Science.gov (United States)

    Armour, E P; Raaphorst, G P

    2004-03-01

    Combining long duration mild temperature hyperthermia (LDMH) and low dose-rate (LDR) brachytherapy to enhance therapeutic killing of cancer cells was proposed many years ago. The cellular and tumour research that supports this hypothesis is presented in this review. Research describing LDMH interaction with pulsed brachytherapy and high dose-rate brachytherapy using clinically relevant parameters are compared with LDMH/LDR brachytherapy. The mechanism by which LDMH sensitizes LDR has been established as the inhibition of sublethal damage repair. The molecular mechanisms have been shown to involve DNA repair enzymes, but the exact nature of these processes is still under investigation. The relative differences between LDMH interactions with human and rodent cells are presented to help in the understanding of possible roles of LDMH in clinical application. The role of LDMH in modifying tumour blood flow and its possible role in LDR sensitization of tumours is also presented. The positive aspects of LDMH-brachytherapy for clinical application are sixfold; (1) the thermal goals (temperature, time and volume) are achievable with currently available technology, (2) the hyperthermia by itself has no detectable toxic effects, (3) thermotolerance appears to play a minor if any role in radiation sensitization, (4) TER of around 2 can be expected, (5) hypoxic fraction may be decreased due to blood flow modification and (6) simultaneous chemotherapy may also be sensitized. Combined LDMH and brachytherapy is a cancer therapy that has established biological rationale and sufficient technical and clinical advancements to be appropriately applied. This modality is ripe for clinical testing.

  2. What to Know about Brachytherapy (A Type of Internal Radiation Therapy)

    Science.gov (United States)

    ... What To Know About Brachytherapy (A Type of Internal Radiation Therapy) “I asked questions. My doctor took the time ... most. Understanding Radiation Therapy: Brachytherapy (A Type of Internal Radiation Therapy) Types of brachytherapy: Low-dose rate (LDR) implants ...

  3. Prostate cancer brachytherapy

    International Nuclear Information System (INIS)

    Abreu, Carlos Eduardo Vita; Silva, Joao L. F.; Srougi, Miguel; Nesrallah, Adriano

    1999-01-01

    The transperineal brachytherapy with 125 I/Pd 103 seed implantation guided by transurethral ultrasound must be presented as therapeutical option of low urinary morbidity in patients with localized prostate cancer. The combined clinical staging - including Gleason and initial PSA - must be encouraged, for definition of a group of low risk and indication of exclusive brachytherapy. Random prospective studies are necessary in order to define the best role of brachytherapy, surgery and external beam radiation therapy

  4. Single-Fraction High-Dose-Rate Brachytherapy and Hypofractionated External Beam Radiation Therapy in the Treatment of Intermediate-Risk Prostate Cancer - Long Term Results

    Energy Technology Data Exchange (ETDEWEB)

    Cury, Fabio L., E-mail: fabio.cury@muhc.mcgill.ca [Department of Radiation Oncology, McGill University Health Centre, Montreal, QC (Canada); Duclos, Marie [Department of Radiation Oncology, McGill University Health Centre, Montreal, QC (Canada); Aprikian, Armen [Department of Urology, McGill University Health Centre, Montreal, QC (Canada); Patrocinio, Horacio [Department of Medical Physics, McGill University Health Centre, Montreal, QC (Canada); Kassouf, Wassim [Department of Urology, McGill University Health Centre, Montreal, QC (Canada); Shenouda, George; Faria, Sergio; David, Marc; Souhami, Luis [Department of Radiation Oncology, McGill University Health Centre, Montreal, QC (Canada)

    2012-03-15

    Purpose: We present the long-term results of a cohort of patients with intermediate-risk prostate cancer (PC) treated with single-fraction high-dose-rate brachytherapy (HDRB) combined with hypofractionated external beam radiation therapy (HypoRT). Methods and Materials: Patients were treated exclusively with HDRB and HypoRT. HDRB delivered a dose of 10 Gy to the prostate surface and HypoRT consisted of 50 Gy delivered in 20 daily fractions. The first 121 consecutive patients with a minimum of 2 years posttreatment follow-up were assessed for toxicity and disease control. Results: The median follow-up was 65.2 months. No acute Grade III or higher toxicity was seen. Late Grade II gastrointestinal toxicity was seen in 9 patients (7.4%) and Grade III in 2 (1.6%). Late Grade III genitourinary toxicity was seen in 2 patients (1.6%). After a 24-month follow-up, a rebiopsy was offered to the first 58 consecutively treated patients, and 44 patients agreed with the procedure. Negative biopsies were found in 40 patients (91%). The 5-year biochemical relapse-free survival rate was 90.7% (95% CI, 84.5-96.9%), with 13 patients presenting biochemical failure. Among them, 9 were diagnosed with distant metastasis. Prostate cancer-specific and overall survival rates at 5 years were 100% and 98.8% (95% CI, 96.4-100%), respectively. Conclusion: The combination of HDRB and HypoRT is well tolerated, with acceptable toxicity rates. Furthermore, results from rebiopsies revealed an encouraging rate of local control. These results confirm that the use of conformal RT techniques, adapted to specific biological tumor characteristics, have the potential to improve the therapeutic ratio in intermediate-risk PC patients.

  5. Dose specification for 192Ir high dose rate brachytherapy in terms of dose-to-water-in-medium and dose-to-medium-in-medium

    International Nuclear Information System (INIS)

    Fonseca, Gabriel Paiva; Yoriyaz, Hélio; Tedgren, Åsa Carlsson; Nilsson, Josef; Persson, Maria; Reniers, Brigitte; Verhaegen, Frank

    2015-01-01

    Dose calculation in high dose rate brachytherapy with 192 Ir is usually based on the TG-43U1 protocol where all media are considered to be water. Several dose calculation algorithms have been developed that are capable of handling heterogeneities with two possibilities to report dose: dose-to-medium-in-medium (D m,m ) and dose-to-water-in-medium (D w,m ). The relation between D m,m and D w,m for 192 Ir is the main goal of this study, in particular the dependence of D w,m on the dose calculation approach using either large cavity theory (LCT) or small cavity theory (SCT). A head and neck case was selected due to the presence of media with a large range of atomic numbers relevant to tissues and mass densities such as air, soft tissues and bone interfaces. This case was simulated using a Monte Carlo (MC) code to score: D m,m, D w,m (LCT), mean photon energy and photon fluence. D w,m (SCT) was derived from MC simulations using the ratio between the unrestricted collisional stopping power of the actual medium and water. Differences between D m,m and D w,m (SCT or LCT) can be negligible (<1%) for some tissues e.g. muscle and significant for other tissues with differences of up to 14% for bone. Using SCT or LCT approaches leads to differences between D w,m (SCT) and D w,m (LCT) up to 29% for bone and 36% for teeth. The mean photon energy distribution ranges from 222 keV up to 356 keV. However, results obtained using mean photon energies are not equivalent to the ones obtained using the full, local photon spectrum. This work concludes that it is essential that brachytherapy studies clearly report the dose quantity. It further shows that while differences between D m,m and D w,m (SCT) mainly depend on tissue type, differences between D m,m and D w,m (LCT) are, in addition, significantly dependent on the local photon energy fluence spectrum which varies with distance to implanted sources. (paper)

  6. Improved tissue assignment using dual-energy computed tomography in low-dose rate prostate brachytherapy for Monte Carlo dose calculation

    Energy Technology Data Exchange (ETDEWEB)

    Côté, Nicolas [Département de Physique, Université de Montréal, Pavillon Roger-Gaudry (D-428), 2900 Boulevard Édouard-Montpetit, Montréal, Québec H3T 1J4 (Canada); Bedwani, Stéphane [Département de Radio-Oncologie, Centre Hospitalier de l’Université de Montréal (CHUM), 1560 Rue Sherbrooke Est, Montréal, Québec H2L 4M1 (Canada); Carrier, Jean-François, E-mail: jean-francois.carrier.chum@ssss.gouv.qc.ca [Département de Physique, Université de Montréal, Pavillon Roger-Gaudry (D-428), 2900 Boulevard Édouard-Montpetit, Montréal, Québec H3T 1J4, Canada and Département de Radio-Oncologie, Centre Hospitalier de l’Université de Montréal (CHUM), 1560 Rue Sherbrooke Est, Montréal, Québec H2L 4M1 (Canada)

    2016-05-15

    Purpose: An improvement in tissue assignment for low-dose rate brachytherapy (LDRB) patients using more accurate Monte Carlo (MC) dose calculation was accomplished with a metallic artifact reduction (MAR) method specific to dual-energy computed tomography (DECT). Methods: The proposed MAR algorithm followed a four-step procedure. The first step involved applying a weighted blend of both DECT scans (I {sub H/L}) to generate a new image (I {sub Mix}). This action minimized Hounsfield unit (HU) variations surrounding the brachytherapy seeds. In the second step, the mean HU of the prostate in I {sub Mix} was calculated and shifted toward the mean HU of the two original DECT images (I {sub H/L}). The third step involved smoothing the newly shifted I {sub Mix} and the two original I {sub H/L}, followed by a subtraction of both, generating an image that represented the metallic artifact (I {sub A,(H/L)}) of reduced noise levels. The final step consisted of subtracting the original I {sub H/L} from the newly generated I {sub A,(H/L)} and obtaining a final image corrected for metallic artifacts. Following the completion of the algorithm, a DECT stoichiometric method was used to extract the relative electronic density (ρ{sub e}) and effective atomic number (Z {sub eff}) at each voxel of the corrected scans. Tissue assignment could then be determined with these two newly acquired physical parameters. Each voxel was assigned the tissue bearing the closest resemblance in terms of ρ{sub e} and Z {sub eff}, comparing with values from the ICRU 42 database. A MC study was then performed to compare the dosimetric impacts of alternative MAR algorithms. Results: An improvement in tissue assignment was observed with the DECT MAR algorithm, compared to the single-energy computed tomography (SECT) approach. In a phantom study, tissue misassignment was found to reach 0.05% of voxels using the DECT approach, compared with 0.40% using the SECT method. Comparison of the DECT and SECT D

  7. A Novel Form of Breast Intraoperative Radiation Therapy With CT-Guided High-Dose-Rate Brachytherapy: Results of a Prospective Phase 1 Clinical Trial

    Energy Technology Data Exchange (ETDEWEB)

    Showalter, Shayna L., E-mail: snl2t@virginia.edu [Division of Surgical Oncology, Department of Surgery, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Petroni, Gina [Division of Translation Research and Applied Statistics, Department of Public Health Sciences, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Trifiletti, Daniel M.; Libby, Bruce [Department of Radiation Oncology, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Schroen, Anneke T.; Brenin, David R. [Division of Surgical Oncology, Department of Surgery, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Dalal, Parchayi [Department of Radiation Oncology, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Smolkin, Mark [Division of Translation Research and Applied Statistics, Department of Public Health Sciences, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Reardon, Kelli A.; Showalter, Timothy N. [Department of Radiation Oncology, University of Virginia School of Medicine, Charlottesville, Virginia (United States)

    2016-09-01

    Purpose: Existing intraoperative radiation therapy (IORT) techniques are criticized for the lack of image guided treatment planning and energy deposition with, at times, poor resultant dosimetry and low radiation dose. We pioneered a novel method of IORT that incorporates customized, computed tomography (CT)-based treatment planning and high-dose-rate (HDR) brachytherapy to overcome these drawbacks: CT-HDR-IORT. Methods and Materials: A phase 1 study was conducted to demonstrate the feasibility and safety of CT-HDR-IORT. Eligibility criteria included age ≥50 years, invasive or in situ breast cancer, tumor size <3 cm, and N0 disease. Patients were eligible before or within 30 days of breast-conserving surgery (BCS). BCS was performed, and a multilumen balloon catheter was placed. CT images were obtained, a customized HDR brachytherapy plan was created, and a dose of 12.5 Gy was delivered to 1-cm depth from the balloon surface. The catheter was removed, and the skin was closed. The primary endpoints were feasibility and acute toxicity. Feasibility was defined as IORT treatment interval (time from CT acquisition until IORT completion) ≤90 minutes. The secondary endpoints included dosimetry, cosmetic outcome, quality of life, and late toxicity. Results: Twenty-eight patients were enrolled. The 6-month follow-up assessments were completed by 93% of enrollees. The median IORT treatment interval was 67.2 minutes (range, 50-108 minutes). The treatment met feasibility criteria in 26 women (93%). The dosimetric goals were met in 22 patients (79%). There were no Radiation Therapy Oncology Group grade 3+ toxicities; 6 patients (21%) experienced grade 2 events. Most patients (93%) had good/excellent cosmetic outcomes at the last follow-up visit. Conclusions: CT-HDR-IORT is feasible and safe. This promising approach for a conformal, image-based, higher-dose breast IORT is being evaluated in a phase 2 trial.

  8. Radiotherapy alone in the treatment of uterine cervix cancer with telecobalt and low-dose-rate brachytherapy: retrospective analysis of results and variables

    International Nuclear Information System (INIS)

    Ferrigno, Robson; Campos de Oliveira Faria, Sergio Luis; Weltman, Eduardo; Salvajoli, Joao Victor; Segreto, Roberto Araujo; Pastore, Ayrton; Nadalin, Wladimir

    2003-01-01

    Purpose: This retrospective analysis aims to report results and variables from patients with cervix cancer treated by radiation therapy alone with telecobalt and low-dose-rate brachytherapy (LDRB). Methods and Materials: Between September 1989 and September 1995, 190 patients with histologic diagnosis of cervix carcinoma were treated with telecobalt for external beam radiotherapy (EBR), followed by one or two insertions of LDRB. Stage distribution according to patients was the following: IB, 12; IIA, 4; IIB, 105; and IIIB, 69. Median dose of EBR at whole pelvis was 40 Gy, and median parametrial doses for Stages II and III patients were 50 Gy and 60 Gy, respectively. Median doses of LDRB at point A for patients treated with one and two insertions were 38 Gy and 50 Gy, respectively. Results: Median follow-up time was 70 months (range: 8-127 months). Overall survival, disease-free survival, and 5-year local control of patients at Stages I, II, and III were 83%, 78%, and 46%; 83%, 82%, and 49%; and 92%, 87%, and 58%, respectively. Overall incidence of late complications in the rectum, small bowel, and urinary tract was 15.3% (19/190), 4.2% (8/190), and 6.8% (13/190), respectively. The actuarial 5-year rectal, small bowel, and urinary incidence of late complications was 16.1%, 4.6%, and 7.6%, respectively. Clinical stage was the only significant variable for overall 5-year survival (p = 0.001), for disease-free survival (p=0.001), and for local control (p=0.001). Stage II patients more than 50 years old had better disease-free survival and local control at 5 years (p=0.004). None of the analyzed variables influenced the actuarial 5-year incidence of late complications. Conclusions: Results of this series suggest that the use of telecobalt equipment for EBR with doses up to 50 Gy at whole pelvis, prior to brachytherapy, is an acceptable technique for radiation therapy alone in the treatment of cervix cancer, especially in developing countries, including Brazil, where

  9. Incidence of Second Malignancies in Prostate Cancer Patients Treated With Low-Dose-Rate Brachytherapy and Radical Prostatectomy

    Energy Technology Data Exchange (ETDEWEB)

    Hamilton, Sarah Nicole; Tyldesley, Scott [Department of Surgery, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia (Canada); Department of Radiation Oncology, British Columbia Cancer Agency–Vancouver Centre, Vancouver, British Columbia (Canada); Hamm, Jeremy [Department of Population Oncology, British Columbia Cancer Agency–Vancouver Centre, Vancouver, British Columbia (Canada); Jiang, Wei Ning [Faculty of Medicine, University of British Columbia, Vancouver, British Columbia (Canada); Keyes, Mira; Pickles, Tom [Department of Surgery, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia (Canada); Department of Radiation Oncology, British Columbia Cancer Agency–Vancouver Centre, Vancouver, British Columbia (Canada); Lapointe, Vince [Department of Medical Physics, British Columbia Cancer Agency–Vancouver Centre, Vancouver, British Columbia (Canada); Kahnamelli, Adam [Department of Radiation Oncology, British Columbia Cancer Agency–Vancouver Centre, Vancouver, British Columbia (Canada); McKenzie, Michael [Department of Surgery, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia (Canada); Department of Radiation Oncology, British Columbia Cancer Agency–Vancouver Centre, Vancouver, British Columbia (Canada); Miller, Stacy [Department of Radiation Oncology, British Columbia Cancer Agency–Centre for the North, Prince George, British Columbia (Canada); Morris, W. James, E-mail: jmorris@bccancer.bc.ca [Department of Surgery, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia (Canada); Department of Radiation Oncology, British Columbia Cancer Agency–Vancouver Centre, Vancouver, British Columbia (Canada)

    2014-11-15

    Purpose: To compare the second malignancy incidence in prostate cancer patients treated with brachytherapy (BT) relative to radical prostatectomy (RP) and to compare both groups with the cancer incidence in the general population. Methods and Materials: From 1998 to 2010, 2418 patients were treated with Iodine 125 prostate BT monotherapy at the British Columbia Cancer Agency, and 4015 referred patients were treated with RP. Cancer incidence was compared with the age-matched general population using standardized incidence ratios (SIRs). Pelvic malignancies included invasive and noninvasive bladder cancer and rectal cancer. Cox multivariable analysis was performed with adjustment for covariates to determine whether treatment (RP vs BT) was associated with second malignancy risk. Results: The median age at BT was 66 years and at RP 62 years. The SIR comparing BT patients with the general population was 1.06 (95% confidence interval [CI] 0.91-1.22) for second malignancy and was 1.53 (95% CI 1.12-2.04) for pelvic malignancy. The SIR comparing RP patients with the general population was 1.11 (95% CI 0.98-1.25) for second malignancy and was 1.11 (95% CI 0.82-1.48) for pelvic malignancy. On multivariable analysis, older age (hazard ratio [HR] 1.05) and smoking (HR 1.65) were associated with increased second malignancy risk (P<.0001). Radical prostatectomy was not associated with a decreased second malignancy risk relative to BT (HR 0.90, P=.43), even when excluding patients who received postprostatectomy external beam radiation therapy (HR 1.13, P=.25). Older age (HR 1.09, P<.0001) and smoking (HR 2.17, P=.0009) were associated with increased pelvic malignancy risk. Radical prostatectomy was not associated with a decreased pelvic malignancy risk compared with BT (HR 0.57, P=.082), even when excluding postprostatectomy external beam radiation therapy patients (HR 0.87, P=.56). Conclusions: After adjustment for covariates, BT patients did not have an increased second

  10. Computed tomography-based treatment planning for high-dose-rate brachytherapy using the tandem and ring applicator: influence of applicator choice on organ dose and inter-fraction adaptive planning

    Directory of Open Access Journals (Sweden)

    Vishruta A. Dumane

    2017-06-01

    Full Text Available Three dimensional planning for high-dose-rate (HDR brachytherapy in cervical cancer has been highly recommended by consensus guidelines such as the American Brachytherapy Society (ABS and the Groupe Européen de Curiethérapie – European Society for Radiotherapy and Oncology (GEC-ESTRO. In this document, we describe our experience with computed tomography (CT-based planning using the tandem/ring applicator. We discuss the influence of applicator geometry on doses to organs at risk (OARs, namely the bladder, rectum, and sigmoid. Through example cases with dose prescribed to point A, we demonstrate how adaptive planning can help achieve constraints to the OARs as per guidelines.

  11. An Internet-ready database for prospective randomized clinical trials of high-dose-rate brachytherapy for adenocarcinoma of the prostate

    International Nuclear Information System (INIS)

    Devlin, Phillip M.; Brus, Christina R.; Kazakin, Julia; Mitchell, Ronald B.; Demanes, D. Jeffrey; Edmundson, Gregory; Gribble, Michael; Gustafson, Gary S.; Kelly, Douglas A.; Linares, Luis A.; Martinez, Alvaro A.; Mate, Timothy P.; Nag, Subir; Perez, Carlos A.; Rao, Jaynath G.; Rodriguez, Rodney R.; Shasha, Daniel; Tripuraneni, Prabhakar

    2002-01-01

    Purpose: To demonstrate a new interactive Internet-ready database for prospective clinical trials in high-dose-rate (HDR) brachytherapy for prostate cancer. Methods and Materials: An Internet-ready database was created that allows common data acquisition and statistical analysis. Patient anonymity and confidentiality are preserved. These data forms include all common elements found from a survey of the databases. The forms allow the user to view patient data in a view-only or edit mode. Eight linked forms document patient data before and after receiving HDR therapy. The pretreatment forms are divided into four categories: staging, comorbid diseases, external beam radiotherapy data, and signs and symptoms. The posttreatment forms separate data by HDR implant information, HDR medications, posttreatment signs and symptoms, and follow-up data. The forms were tested for clinical usefulness. Conclusion: This Internet-based database enables the user to record and later analyze all relevant medical data and may become a reliable instrument for the follow-up of patients and evaluation of treatment results

  12. Clinical application of a OneDose(TM) MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast

    International Nuclear Information System (INIS)

    Kinhikar, Rajesh A; Sharma, Pramod K; Tambe, Chandrashekhar M; Mahantshetty, Umesh M; Sarin, Rajiv; Deshpande, Deepak D; Shrivastava, Shyam K

    2006-01-01

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose(TM) in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs. (note)

  13. Primary calibration of coiled 103Pd brachytherapy sources

    International Nuclear Information System (INIS)

    Paxton, Adam B.; Culberson, Wesley S.; DeWerd, Larry A.; Micka, John A.

    2008-01-01

    Coiled 103 Pd brachytherapy sources have been developed by RadioMed Corporation for use as low-dose-rate (LDR) interstitial implants. The coiled sources are provided in integer lengths from 1 to 6 cm and address many common issues seen with traditional LDR brachytherapy sources. The current standard for determining the air-kerma strength (S K ) of low-energy LDR brachytherapy sources is the National Institute of Standards and Technology's Wide-Angle Free-Air Chamber (NIST WAFAC). Due to geometric limitations, however, the NIST WAFAC is unable to determine the S K of sources longer than 1 cm. This project utilized the University of Wisconsin's Variable-Aperture Free-Air Chamber (UW VAFAC) to determine the S K of the longer coiled sources. The UW VAFAC has shown agreement in S K values of 1 cm length coils to within 1% of those determined with the NIST WAFAC, but the UW VAFAC does not share the same geometric limitations as the NIST WAFAC. A new source holder was constructed to hold the coiled sources in place during measurements with the UW VAFAC. Correction factors for the increased length of the sources have been determined and applied to the measurements. Using the new source holder and corrections, the S K of 3 and 6 cm coiled sources has been determined. Corrected UW VAFAC data and ionization current measurements from well chambers have been used to determine calibration coefficients for use in the measurement of 3 and 6 cm coiled sources in well chambers. Thus, the UW VAFAC has provided the first transferable, primary measurement of low-energy LDR brachytherapy sources with lengths greater than 1 cm

  14. SU-E-T-413: Examining Acquisition Rate for Using MatriXX Ion Chamber Array to Measure HDR Brachytherapy Treatments

    International Nuclear Information System (INIS)

    Wagar, M; Bhagwat, M; O’Farrell, D; Friesen, S; Buzurovic, I; Damato, A; Devlin, P; Cormack, R

    2015-01-01

    Purpose: There are unique obstacles to implementing the MatriXX ionchamber array as a QA tool in Brachytherapy given that the device is designed for use in the MV energy range. One of the challenges we investigate is the affect of acquisition rates on dose measurement accuracy for HDR treatment plans. Methods: A treatment plan was optimized in Oncentra Brachy TPS to deliver a planar dose to a 5×5cm region at 10mm depth. The applicator was affixed to the surface of the MatriXX array. The plan was delivered multiple times using a Nucleatron HDR afterloader with a 2.9Ci Ir192 source. For each measurement the sampling rate of the MatriXX movie mode was varied (30ms and 500ms). This experiment was repeated with identical parameters, following a source exchange, with an 11.2Ci Ir192 source. Finally, a single snap measurement was acquired. Analysis was preformed to evaluate the fidelity of the dose delivery for each iteration of the experiment. Evaluation was based on the comparison between the measured and TPS predicted dose. Results: Higher sample rates induce a greater discrepancy between the predicted and measured dose. Delivering the plan using a lower activity source also produced greater discrepancy in the measurement due to the increased delivery time. Analyzing the single snap measurement showed little difference from the 500ms integral dose measurement. Conclusion: The advantage of using movie mode for HDR treatment delivery QA is the ability for real time source tracking in addition to dose measurement. Our analysis indicates that 500ms is an optimal frame rate

  15. SU-E-T-413: Examining Acquisition Rate for Using MatriXX Ion Chamber Array to Measure HDR Brachytherapy Treatments

    Energy Technology Data Exchange (ETDEWEB)

    Wagar, M; Bhagwat, M; O’Farrell, D; Friesen, S; Buzurovic, I; Damato, A; Devlin, P; Cormack, R [Dana-Farber/Brigham and Women’s Cancer Center, Harvard Medical School, Boston, MA (United States)

    2015-06-15

    Purpose: There are unique obstacles to implementing the MatriXX ionchamber array as a QA tool in Brachytherapy given that the device is designed for use in the MV energy range. One of the challenges we investigate is the affect of acquisition rates on dose measurement accuracy for HDR treatment plans. Methods: A treatment plan was optimized in Oncentra Brachy TPS to deliver a planar dose to a 5×5cm region at 10mm depth. The applicator was affixed to the surface of the MatriXX array. The plan was delivered multiple times using a Nucleatron HDR afterloader with a 2.9Ci Ir192 source. For each measurement the sampling rate of the MatriXX movie mode was varied (30ms and 500ms). This experiment was repeated with identical parameters, following a source exchange, with an 11.2Ci Ir192 source. Finally, a single snap measurement was acquired. Analysis was preformed to evaluate the fidelity of the dose delivery for each iteration of the experiment. Evaluation was based on the comparison between the measured and TPS predicted dose. Results: Higher sample rates induce a greater discrepancy between the predicted and measured dose. Delivering the plan using a lower activity source also produced greater discrepancy in the measurement due to the increased delivery time. Analyzing the single snap measurement showed little difference from the 500ms integral dose measurement. Conclusion: The advantage of using movie mode for HDR treatment delivery QA is the ability for real time source tracking in addition to dose measurement. Our analysis indicates that 500ms is an optimal frame rate.

  16. Proposal of a postal system for Ir-192 sources calibration used in high dose rate brachytherapy with LiF:Mn:Ti thermoluminescent dosemeters; Proposta de um sistema postal para a calibracao de fontes de {sup 192} Ir, utilizadas em braquiterapia de alta taxa de dose, com dosimetros termoluminescentes de LiF: Mn: Ti

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, W.S.; Borges, J.C.; Almeida, C.E.V. [Instituto de Radioprotecao e Dosimetria. CNEN Caixa Postal 37750, 22780-160, Rio de Janeiro (Brazil)

    1998-12-31

    A proposal in order to improve the brachytherapy quality control and to allow postal intercomparison of Ir-192 sources used in high dose rate brachytherapy has been presented. The LiF: Mn: Ti (TLD 100) detector has been selected for such purpose. The experimental array and the TLDs irradiation and calibration techniques, at the treatment units, have been specified in the light of more recent methodology of Ir-192 calibration sources. (Author)

  17. Rectal Bleeding After High-Dose-Rate Brachytherapy Combined With Hypofractionated External-Beam Radiotherapy for Localized Prostate Cancer: The Relationship Between Dose-Volume Histogram Parameters and the Occurrence Rate

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, Masahiko, E-mail: masaoka@showa.gunma-u.ac.jp [Department of Radiation Oncology, Gunma University Graduate School of Medicine, Gunma (Japan); Ishikawa, Hitoshi; Ebara, Takeshi; Kato, Hiroyuki; Tamaki, Tomoaki [Department of Radiation Oncology, Gunma University Graduate School of Medicine, Gunma (Japan); Akimoto, Tetsuo [Department of Radiation Oncology, Tokyo Women' s Medical University, Tokyo (Japan); Ito, Kazuto; Miyakubo, Mai; Yamamoto, Takumi; Suzuki, Kazuhiro [Department of Urology, Gunma University Graduate School of Medicine, Gunma (Japan); Takahashi, Takeo; Nakano, Takashi [Department of Radiation Oncology, Gunma University Graduate School of Medicine, Gunma (Japan)

    2012-02-01

    Purpose: To determine the predictive risk factors for Grade 2 or worse rectal bleeding after high-dose-rate brachytherapy (HDR-BT) combined with hypofractionated external-beam radiotherapy (EBRT) for prostate cancer using dose-volume histogram analysis. Methods and Materials: The records of 216 patients treated with HDR-BT combined with EBRT were analyzed. The treatment protocols for HDR-BT were 5 Gy Multiplication-Sign five times in 3 days or 7 Gy Multiplication-Sign three, 10.5 Gy Multiplication-Sign two, or 9 Gy Multiplication-Sign two in 2 days. The EBRT doses ranged from 45 to 51 Gy with a fractional dose of 3 Gy. Results: In 20 patients Grade 2 or worse rectal bleeding developed, and the cumulative incidence rate was 9% at 5 years. By converting the HDR-BT and EBRT radiation doses into biologic effective doses (BED), the BED{sub 3} at rectal volumes of 5% and 10% in the patients who experienced bleeding were significantly higher than those in the remaining 196 patients. Univariate analysis showed that a higher rectal BED{sub 3-5%} and the use of fewer needles in brachytherapy were correlated with the incidence of bleeding, but BED{sub 3-5%} was found to be the only significant factor on multivariate analysis. Conclusions: The radiation dose delivered to small rectal lesions as 5% is important for predicting Grade 2 or worse rectal bleeding after HDR-BT combined with EBRT for prostate cancer.

  18. A quality indicator to evaluate high-dose-rate intracavitary brachytherapy for cancer of the cervix; Determinacao de um indicador de qualidade para avaliar a braquiterapia intracavitaria com alta taxa de dose no cancer do colo uterino

    Energy Technology Data Exchange (ETDEWEB)

    Morales, Francisco Contreras; Soboll, Daniel Scheidegger [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Radioterapia. Servico de Fisica Medica

    2000-12-01

    The aim of this report is to prevent a simple quality indicator (QI) that can be promptly used to evaluate the high-dose-rate (HDR) intracavitary brachytherapy for the treatment of cancer of the cervix, and if necessary, to correct applicators' geometry before starting the treatment. We selected 51 HDR intracavitary applications of brachytherapy of patients with carcinoma of the cervix treated with 60 mm uterine tandem and small Fletcher colpostat, according to the Manchester method (dose prescription on point A). A QI was defined as the ratio between the volume of 100% isodose curve of the study insertion and the volume of the 100% isodose curve of an insertion considered to be ideal. The data obtained were distributed in three groups: the group with tandem placement slippage (67,5%), a group with colpostat placement slippage (21,9%), and a third group, considered normal (10,6%). Each group showed particular characteristics (p < 0.0001). QI can be the best auxiliary method to establish the error tolerance (%) allowed for HDR intracavitary brachytherapy. (author)

  19. Dose to the bladder neck is the most important predictor for acute and late toxicity after low-dose-rate prostate brachytherapy: implications for establishing new dose constraints for treatment planning.

    Science.gov (United States)

    Hathout, Lara; Folkert, Michael R; Kollmeier, Marisa A; Yamada, Yoshiya; Cohen, Gil'ad N; Zelefsky, Michael J

    2014-10-01

    To identify an anatomic structure predictive for acute (AUT) and late (LUT) urinary toxicity in patients with prostate cancer treated with low-dose-rate brachytherapy (LDR) with or without external beam radiation therapy (EBRT). From July 2002 to January 2013, 927 patients with prostate cancer (median age, 66 years) underwent LDR brachytherapy with Iodine 125 (n=753) or Palladium 103 (n=174) as definitive treatment (n=478) and as a boost (n=449) followed by supplemental EBRT (median dose, 50.4 Gy). Structures contoured on the computed tomographic (CT) scan on day 0 after implantation included prostate, urethra, bladder, and the bladder neck, defined as 5 mm around the urethra between the catheter balloon and the prostatic urethra. AUT and LUT were assessed with the Common Terminology Criteria for Adverse Events, version4. Clinical and dosimetric factors associated with AUT and LUT were analyzed with Cox regression and receiver operating characteristic analysis to calculate area under the receiver operator curve (ROC) (AUC). Grade ≥2 AUT and grade ≥2 LUT occurred in 520 patients (56%) and 154 patients (20%), respectively. No grade 4 toxicities were observed. Bladder neck D2cc retained a significant association with AUT (hazard ratio [HR], 1.03; 95% confidence interval [CI], 1.03-1.04; PLUT (HR, 1.01; 95% CI, 1.00-1.03; P=.014) on multivariable analysis. In a comparison of bladder neck with the standard dosimetric variables by use of ROC analysis (prostate V100 >90%, D90 >100%, V150 >60%, urethra D20 >130%), bladder neck D2cc >50% was shown to have the strongest prognostic power for AUT (AUC, 0.697; PLUT (AUC, 0.620; P50% was the strongest predictor for grade ≥2 AUT and LUT in patients treated with LDR brachytherapy. These data support inclusion of bladder neck constraints into brachytherapy planning to decrease urinary toxicity. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Attenuation measurements show that the presence of a TachoSil surgical patch will not compromise target irradiation in intra-operative electron radiation therapy or high-dose-rate brachytherapy.

    Science.gov (United States)

    Sarmento, Sandra; Costa, Filipa; Pereira, Alexandre; Lencart, Joana; Dias, Anabela; Cunha, Luís; Sousa, Olga; Silva, José Pedro; Santos, Lúcio

    2015-01-09

    Surgery of locally advanced and/or recurrent rectal cancer can be complemented with intra-operative electron radiation therapy (IOERT) to deliver a single dose of radiation directly to the unresectable margins, while sparing nearby sensitive organs/structures. Haemorrhages may occur and can affect the dose distribution, leading to an incorrect target irradiation. The TachoSil (TS) surgical patch, when activated, creates a fibrin clot at the surgical site to achieve haemostasis. The aim of this work was to determine the effect of TS on the dose distribution, and ascertain whether it could be used in combination with IOERT. This characterization was extended to include high dose rate (HDR) intraoperative brachytherapy, which is sometimes used at other institutions instead of IOERT. CT images of the TS patch were acquired for initial characterization. Dosimetric measurements were performed in a water tank phantom, using a conventional LINAC with a hard-docking system of cylindrical applicators. Percentage Depth Dose (PDD) curves were obtained, and measurements made at the depth of dose maximum for the three clinically used electron energies (6, 9 and 12MeV), first without any attenuator and then with the activated patch of TS completely covering the tip of the IOERT applicator. For HDR brachytherapy, a measurement setup was improvised using a solid water phantom and a Farmer ionization chamber. Our measurements show that the attenuation of a TachoSil patch is negligible, both for high energy electron beams (6 to 12MeV), and for a HDR (192)Ir brachytherapy source. Our results cannot be extrapolated to lower beam energies such as 50 kVp X-rays, which are sometimes used for breast IORT. The TachoSil surgical patch can be used in IORT procedures using 6MeV electron energies or higher, or HDR (192)Ir brachytherapy.

  1. Deriving health state utilities for the numerical pain rating scale

    Directory of Open Access Journals (Sweden)

    Retsa Peny

    2011-11-01

    Full Text Available Abstract Background The use of patient reported outcome measures within cost-effectiveness analysis has become commonplace. However, specific measures are required that produce values, referred to as 'utilities', that are capable of generating quality adjusted life years. One such measure - the EQ-5D - has come under criticism due to the inherent limitations of its three-level response scales. In evaluations of chronic pain, the numerical pain rating scale (NPRS which has eleven levels is routinely used which has a greater measurement range, but which can not be used in cost-effetiveness analyses. This study derived utility values for a series of EQ-5D health states that replace the pain dimensions with the NPRS, thereby allowing a potentially greater range of pain intensities to be captured and included in economic analyses. Methods Interviews were undertaken with 100 member of the general population. Health state valuations were elicited using the time trade-off approach with a ten year time horizon. Additionally, respondents were asked where the EQ-5D response scale descriptors of moderate and extreme pain lay on the 11-point NPRS scale. Results 625 valuations were undertaken across the study sample with the crude mean health state utilities showing a negative non-linear relationship with respect to increasing pain intensity. Relative to a NPRS of zero (NPRS0, the successive pain levels (NPRS1-10 had mean decrements in utility of 0.034, 0.043, 0.061, 0.121, 0.144, 0.252, 0.404, 0.575, 0.771 and 0.793, respectively. When respondents were asked to mark on the NPRS scale the EQ-5D pain descriptors of moderate and extreme pain, the median responses were '4' and '8', respectively. Conclusions These results demonstrate the potential floor effect of the EQ-5D with respect to pain and provide estimates of health reduction associated with pain intensity described by the NPRS. These estimates are in excess of the decrements produced by an application

  2. A generic high-dose rate {sup 192}Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism

    Energy Technology Data Exchange (ETDEWEB)

    Ballester, Facundo, E-mail: Facundo.Ballester@uv.es [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Carlsson Tedgren, Åsa [Department of Medical and Health Sciences (IMH), Radiation Physics, Faculty of Health Sciences, Linköping University, Linköping SE-581 85, Sweden and Department of Medical Physics, Karolinska University Hospital, Stockholm SE-171 76 (Sweden); Granero, Domingo [Department of Radiation Physics, ERESA, Hospital General Universitario, Valencia E-46014 (Spain); Haworth, Annette [Department of Physical Sciences, Peter MacCallum Cancer Centre and Royal Melbourne Institute of Technology, Melbourne, Victoria 3000 (Australia); Mourtada, Firas [Department of Radiation Oncology, Helen F. Graham Cancer Center, Christiana Care Health System, Newark, Delaware 19713 (United States); Fonseca, Gabriel Paiva [Instituto de Pesquisas Energéticas e Nucleares – IPEN-CNEN/SP, São Paulo 05508-000, Brazil and Department of Radiation Oncology (MAASTRO), GROW, School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht 6201 BN (Netherlands); Zourari, Kyveli; Papagiannis, Panagiotis [Medical Physics Laboratory, Medical School, University of Athens, 75 MikrasAsias, Athens 115 27 (Greece); Rivard, Mark J. [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States); Siebert, Frank-André [Clinic of Radiotherapy, University Hospital of Schleswig-Holstein, Campus Kiel, Kiel 24105 (Germany); Sloboda, Ron S. [Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta T6G 1Z2, Canada and Department of Oncology, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada); and others

    2015-06-15

    Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-based dose calculation algorithms (MBDCAs), treatment planning systems (TPSs) using a MBDCA require a set of well-defined test case plans characterized by Monte Carlo (MC) methods. This also permits direct dose comparison to TG-43 reference data. Such test case plans should be made available for use in the software commissioning process performed by clinical end users. To this end, a hypothetical, generic high-dose rate (HDR) {sup 192}Ir source and a virtual water phantom were designed, which can be imported into a TPS. Methods: A hypothetical, generic HDR {sup 192}Ir source was designed based on commercially available sources as well as a virtual, cubic water phantom that can be imported into any TPS in DICOM format. The dose distribution of the generic {sup 192}Ir source when placed at the center of the cubic phantom, and away from the center under altered scatter conditions, was evaluated using two commercial MBDCAs [Oncentra{sup ®} Brachy with advanced collapsed-cone engine (ACE) and BrachyVision ACUROS{sup TM}]. Dose comparisons were performed using state-of-the-art MC codes for radiation transport, including ALGEBRA, BrachyDose, GEANT4, MCNP5, MCNP6, and PENELOPE2008. The methodologies adhered to recommendations in the AAPM TG-229 report on high-energy brachytherapy source dosimetry. TG-43 dosimetry parameters, an along-away dose-rate table, and primary and scatter separated (PSS) data were obtained. The virtual water phantom of (201){sup 3} voxels (1 mm sides) was used to evaluate the calculated dose distributions. Two test case plans involving a single position of the generic HDR {sup 192}Ir source in this phantom were prepared: (i) source centered in the phantom and (ii) source displaced 7 cm laterally from the center. Datasets were independently produced by

  3. Advancements in brachytherapy

    DEFF Research Database (Denmark)

    Tanderup, Kari; Ménard, Cynthia; Polgar, Csaba

    2017-01-01

    Brachytherapy is a radiotherapy modality associated with a highly focal dose distribution. Brachytherapy treats the cancer tissue from the inside, and the radiation does not travel through healthy tissue to reach the target as with external beam radiotherapy techniques. The nature of brachytherap...

  4. Monte Carlo validation and optimisation of detector packaging for spectroscopic dosimetry for in vivo urethral dosimetry during low dose rate brachytherapy

    International Nuclear Information System (INIS)

    Nourbehesht, L.K.; Cutajar, D.L.; Guatelli, S.; Rosenfeld, A.B.

    2015-01-01

    The urethral mini-dosimeter, developed by the Centre for Medical Radiation Physics, University of Wollongong, uses spectroscopic dosimetry to provide real time point dose measurements along the urethra during low dose rate prostate brachytherapy. Spectroscopic dosimetry uses the measured spectrum of the treatment isotope to estimate the dose rate at the point of measurement, however, the silicon mini-detectors employed in the urethral mini-dosimeter require water proof encapsulation which must be capable of providing electromagnetic shielding without greatly increasing the size of the probe. The introduction of non-tissue equivalent materials within the encapsulation can change the spectrum of radiation incident on the detector, which may influence the application of spectroscopic dosimetry within the urethral dosimeter. The Monte Carlo code Geant4 was adopted to study the effect of encapsulation on the operation of the urethral mini-dosimeter, as well as to determine whether an appropriate thickness of aluminium shielding was possible for electromagnetic screening. The depth dose response and angular dependence of the urethral mini-dosimeter with three thicknesses of aluminium shielding (20, 50, 100 µm) was compared with the urethral mini-dosimeter without aluminium shielding. The aluminium shielding had the effect of increasing the depth dose response (up to 3 % within 30 mm and up to 5 % within 50 mm), slightly reduced the azimuth angular dependence and slightly increased the polar angular dependence. The 100 µm thick shielding provided the least azimuth angular dependence (±2 %) and provided a polar angular dependence of ±1.4 % within the angles of −45° to 45°.

  5. Updated results of high-dose rate brachytherapy and external beam radiotherapy for locally and locally advanced prostate cancer using the RTOG-ASTRO phoenix definition

    Directory of Open Access Journals (Sweden)

    Antonio C. Pellizzon

    2008-06-01

    Full Text Available PURPOSE: To evaluate the prognostic factors for patients with local or locally advanced prostate cancer treated with external beam radiotherapy (RT and high dose rate brachytherapy (HDR according to the RTOG-ASTRO Phoenix Consensus Conference. MATERIALS AND METHODS: The charts of 209 patients treated between 1997 and 2005 with localized RT and HDR as a boost at the Department of Radiation Oncology, AC Camargo Hospital, Sao Paulo, Brazil were reviewed. Clinical and treatment parameters i.e.: patient's age, Gleason score, clinical stage, initial PSA (iPSA, risk group (RG for biochemical failure, doses of RT and HDR were evaluated. Median age and median follow-up time were 68 and 5.3 years, respectively. Median RT and HDR doses were 45 Gy and 20 Gy. RESULTS: Disease specific survival (DSS at 3.3 year was 94.2%. Regarding RG, for the LR (low risk, IR (intermediate risk and HR (high risk, the DSS rates at 3.3 years were 91.5%, 90.2% and 88.5%, respectively. On univariate analysis prognostic factors related to DSS were RG (p = 0.040, Gleason score ≤ 6 ng/mL (p = 0.002, total dose of HDR ≥ 20 Gy (p < 0.001 On multivariate analysis the only statistical significant predictive factor for biochemical control (bNED was the RG, p < 0.001 (CI - 1.147-3.561. CONCLUSIONS: Although the radiation dose administered to the prostate is an important factor related to bNED, this could not be established with statistical significance in this group of patients. To date , in our own experience, HDR associated to RT could be considered a successful approach in the treatment of prostate cancer.

  6. Avaliação da dose no reto em pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do câncer do colo uterino Rectal dose assessment in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer

    Directory of Open Access Journals (Sweden)

    Jetro Pereira de Oliveira

    2009-04-01

    Full Text Available OBJETIVO: O objetivo deste trabalho foi desenvolver um sistema dosimétrico termoluminescente capaz de avaliar as doses administradas ao reto de pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do câncer do colo uterino. MATERIAIS E MÉTODOS: O material termoluminescente utilizado para a avaliação da dose no reto foi o LiF:Mg,Ti,Na na forma de pó. O pó foi separado em pequenas porções de 34 mg, que foram acomodadas em um tubo capilar. Este tubo foi colocado em uma sonda retal, que era introduzida no reto da paciente. RESULTADOS: As doses administradas ao reto de seis pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do câncer do colo uterino foram avaliadas com dosímetros termoluminescentes e apresentaram boa concordância com os valores planejados, com base em duas radiografias ortogonais da paciente, imagens ântero-posterior e lateral. CONCLUSÃO: O sistema de dosimetria termoluminescente utilizado no presente trabalho é simples e de fácil utilização quando comparado a outros métodos de dosimetria do reto. Ele mostrou-se eficiente na avaliação da dose no reto de pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do câncer do colo uterino.OBJECTIVE: The present study was aimed at developing a thermoluminescent dosimetric system capable of assessing the doses delivered to the rectum of patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. MATERIALS AND METHODS: LiF:Mg,Ti,Na powder was the thermoluminescent material utilized for evaluating the rectal dose. The powder was divided into small portions (34 mg which were accommodated in a capillary tube. This tube was placed into a rectal probe that was introduced into the patient's rectum. RESULTS: The doses delivered to the rectum of six patients submitted to high-dose-rate brachytherapy for uterine cervix cancer evaluated by means of thermoluminescent dosimeters presented a good

  7. Definitive Brachytherapy for Kaposi's Sarcoma

    International Nuclear Information System (INIS)

    Williams, A.; Ezzell, G.; Zalupski, M.; Fontanesi, J.

    1996-01-01

    Purpose: To assess the efficacy and possible complications in patients diagnosed with Kaposi's sarcoma and treated with definitive brachytherapy. Methods and Materials: Between January, 1995 and December, 1995, four patients with Kaposi's sarcoma (KS) were treated with brachytherapy. Three patients, all with positive HIV status were treated using Iridium 192 (Ir-192) sources via a high-dose rate remote afterloader. One patient with endemic KS was treated using the application of catheters loaded with Californium 252. Eight sites were treated and included scalp, feet, nose, penis, hand, neck, and back. Dose rate for Ir-192 was 330cGy/fx to a total dose of 990cGy. The Californium was delivered as 100nGy/b.i.d. to a total dose of 900nGy. Follow-up as ranged from 2-6 months. Results: All four patients remain alive. Seven of eight sites have had complete clinical response and each patient has reported durable pain relief that has not subsided through last follow-up of 1/96. Two of eight sites, both treated with surface mold technique with Californium 252 developed moist desquamation. The remaining six sites did not demonstrate significant toxicity. Conclusion: Brachytherapy can offer Kaposi's sarcoma patients results that are equivalent to external beam radiation therapy, with minimal complications, a shorter treatment time and potential cost effectiveness

  8. Preoperative radiotherapy with high dose rate brachytherapy in the treatment of stage IIB cervix cancer. A retrospective analysis of histological specimens

    International Nuclear Information System (INIS)

    Ferrigno, Robson; Trippe, N; Novaes, P.E.; Brandani, I.B.; Hanriot, R.; Souza, L.M.; Pellizzon, A.C.; Salvajoli, J.V.; Baraldi, H.E.; Maia, M.A.; Fogaroli, R.C.

    1996-01-01

    Purpose/Objective: To evaluate the histological specimens of the stage IIB cervix cancer patients who were treated by preoperative radiotherapy with external beam radiotherapy (EBRT) and high dose rate (HDR) brachytherapy. Materials and Methods: From August 1992 to August 1995, 32 patients with stage IIB cervix cancer were underwent to preoperative radiotherapy. All patients received EBRT at the whole pelvis with total dose of 45Gy in 25 fractions of 1,8Gy through a 4 MV linear accelerator. The HDR brachytherapy was realized through a Micro-Selectron device, working with Iridium-192 with initial activity of 10 Ci. The prescribed dose was 6,0Gy at point A, defined by the Manchester, system in 2 weekly insertions during the course of EBRT. The insertions were done by the Fletcher colpostats in association with intrauterine tandem. Four to six weeks after the end of radiotherapy, the patients were underwent to Total Hysterectomy and Salpingoforectomy through Piver second level technique. The uterine specimens were histologically analysed with attention to residual disease at the cervix and lymph nodes status. Results: The histological analysis showed that 19 (59,4%) patients had no residual tumor at the cervix while 13 (40,6%) had microscopic residual tumor. The lymph nodes were negative in 30 (93,8%) patients and positive in 2 (6,3%). All positive lymph nodes patients also had microscopic residual tumor at the cervix. With the follow up ranging from six to 42 months and medium of 21 months, 29 (90,6%) patients are alive with no evidence of disease, one (5,6%) is alive with local recurrence and two (6,2%) have died due to the progression of local disease. Of the 19 patients with negative specimens, 18 (94,7%) are alive with no evidence of disease and of the 13 patients with positive specimens, 11 (84,6%) are alive with no evidence of disease. Local recurrence occurred in two patients with positive specimens and in one with negative. These differences are not

  9. A gEUD-based inverse planning technique for HDR prostate brachytherapy: Feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Giantsoudi, D. [Department of Radiological Sciences, University of Texas Health Sciences Center, San Antonio, Texas 78229 (United States); Department of Radiation Oncology, Francis H. Burr Proton Therapy Center, Boston, Massachusetts 02114 (United States); Baltas, D. [Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach GmbH, 63069 Offenbach (Germany); Nuclear and Particle Physics Section, Physics Department, University of Athens, 15701 Athens (Greece); Karabis, A. [Pi-Medical Ltd., Athens 10676 (Greece); Mavroidis, P. [Department of Radiological Sciences, University of Texas Health Sciences Center, San Antonio, Texas 78299 and Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, 17176 (Sweden); Zamboglou, N.; Tselis, N. [Strahlenklinik, Klinikum Offenbach GmbH, 63069 Offenbach (Germany); Shi, C. [St. Vincent' s Medical Center, 2800 Main Street, Bridgeport, Connecticut 06606 (United States); Papanikolaou, N. [Department of Radiological Sciences, University of Texas Health Sciences Center, San Antonio, Texas 78299 (United States)

    2013-04-15

    Purpose: The purpose of this work was to study the feasibility of a new inverse planning technique based on the generalized equivalent uniform dose for image-guided high dose rate (HDR) prostate cancer brachytherapy in comparison to conventional dose-volume based optimization. Methods: The quality of 12 clinical HDR brachytherapy implants for prostate utilizing HIPO (Hybrid Inverse Planning Optimization) is compared with alternative plans, which were produced through inverse planning using the generalized equivalent uniform dose (gEUD). All the common dose-volume indices for the prostate and the organs at risk were considered together with radiobiological measures. The clinical effectiveness of the different dose distributions was investigated by comparing dose volume histogram and gEUD evaluators. Results: Our results demonstrate the feasibility of gEUD-based inverse planning in HDR brachytherapy implants for prostate. A statistically significant decrease in D{sub 10} or/and final gEUD values for the organs at risk (urethra, bladder, and rectum) was found while improving dose homogeneity or dose conformity of the target volume. Conclusions: Following the promising results of gEUD-based optimization in intensity modulated radiation therapy treatment optimization, as reported in the literature, the implementation of a similar model in HDR brachytherapy treatment plan optimization is suggested by this study. The potential of improved sparing of organs at risk was shown for various gEUD-based optimization parameter protocols, which indicates the ability of this method to adapt to the user's preferences.

  10. Radiotherapy and brachytherapy

    International Nuclear Information System (INIS)

    2007-02-01

    This presentation first defines the radiotherapy and brachytherapy techniques, indicates the used ionizing radiations (electromagnetic and particles), describes the mechanisms and processes of action of ionizing radiations: they can be physical by photon-matter interactions (Compton effect and photoelectric effect) or due to electron-matter interactions (excitation, ionization), physical-chemical by direct or indirect action (DNA damage), cellular (mitotic or apoptotic death), tissue (sane and tumorous tissues and differential effect). It discusses the biological efficiency of these treatments which depends on different parameters: intrinsic radio-sensitivity, time (session fractioning and organisation in time), oxygen, radiation quality, cellular cycle, dose rate, temperature. It presents the different types of radiotherapy: external radiotherapy (general sequence, delineation, dosimetry, protection of critical organs, treatment session, quality control, monitoring consultation) and briefly presents some specific techniques (total body irradiation, total cutaneous electron therapy, pre-operation radiotherapy, radio-surgery, hadron-therapy). It proposes an overview of the main indications for this treatment: brain tumours, upper aero digestive tract tumours, bronchial tumours, oesophagus, stomach and pancreas tumours, breast tumours, cervix cancer, rectum tumour, and so on, and indicates the possible associated treatments. The next part addresses brachytherapy. It presents the principles and comments the differences with radiotherapy. It indicates the used radio-elements (Caesium 137, Iridium 192, Iodine 125), describes the implementation techniques (plastic tubes, use of iodine 125, intracavitary and endo-luminal radiation therapy). It proposes an overview of the different treated tumours (skin, breast, prostates, bronchial, oesophagus, ENT) and indicates possible early and late secondary effects for different organs

  11. American brachytherapy society (ABS) consensus guidelines for brachytherapy of esophageal cancer

    International Nuclear Information System (INIS)

    Gaspar, Laurie E.; Nag, Subir; Herskovic, Arnold; Mantravadi, Rao; Speiser, Burton

    1997-01-01

    Introduction: There is wide variation in the indications, treatment regimens, and dosimetry for brachytherapy in the treatment of cancer of the esophagus. No guidelines for optimal therapy currently exist. Methods and Materials: Utilizing published reports and clinical experience, representatives of the Clinical Research Committee of the American Brachytherapy Society (ABS) formulated guidelines for brachytherapy in esophageal cancer. Results: Recommendations were made for brachytherapy in the definitive and palliative treatment of esophageal cancer. (A) Definitive treatment: Good candidates for brachytherapy include patients with unifocal thoracic adeno- or squamous cancers ≤ 10 cm in length, with no evidence of intra-abdominal or metastatic disease. Contraindications include tracheal or bronchial involvement, cervical esophagus location, or stenosis that cannot be bypassed. The esophageal brachytherapy applicator should have an external diameter of 6-10 mm. If 5FU-based chemotherapy and 45-50-Gy external beam are used, recommended brachytherapy is either: (i) HDR 10 Gy in two weekly fractions of 5 Gy each; or (ii) LDR 20 Gy in a single course at 0.4-1 Gy/hr. All doses are specified 1 cm from the midsource or middwell position. Brachytherapy should follow external beam radiation therapy and should not be given concurrently with chemotherapy. (B) Palliative treatment: Patients with adeno- or squamous cancers of the thoracic esophagus with distant metastases or unresectable local disease progression/recurrence after definitive radiation treatment should be considered for brachytherapy with palliative intent. After limited dose (30 Gy) EBRT, the recommended brachytherapy is either: (i) HDR 10-14 Gy in one or two fractions; or (ii) LDR 20-25 Gy in a single course at 0.4-1 Gy/hr. The need for external beam radiation in newly diagnosed patients with a life expectancy of less than 3 months is controversial. In these cases, HDR of 15-20 Gy in two to four fractions or

  12. Increased genitourinary fistula rate after bevacizumab in recurrent cervical cancer patients initially treated with definitive radiochemotherapy and image-guided adaptive brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Sturdza, Alina; Kirisits, Christian; Poetter, Richard [Medical University of Vienna, Department of Radiation Oncology, Comprehensive Cancer CenterVienna, Vienna (Austria); Hofmann, Sandra; Kranawetter, Marlene; Grimm, Christoph; Schwameis, Richard [Medical University Vienna, Department of general Gynecology and Gynecologic Oncology, Comprehensive Cancer Center Vienna, Vienna (Austria); Polterauer, Stephan; Reinthaller, Alexander [Medical University Vienna, Department of general Gynecology and Gynecologic Oncology, Comprehensive Cancer Center Vienna, Vienna (Austria); Karl Landsteiner Institute for General Gynecology and Experimental Gynecologic Oncology, Vienna (Austria); Krainer, Michael [Medical University Vienna, Clinical Division of Oncology, Department of Medicine 1, Comprehensive Cancer Center, Vienna (Austria)

    2017-12-15

    Patients with recurrent cervical cancer (RecCC) who received defini