WorldWideScience

Sample records for bony bonding studies

  1. Calcification mechanism and bony bonding studies of calcium carbonate and composite aluminosilicate/calcium phosphate applied as biomaterials by using radioactivation methods

    International Nuclear Information System (INIS)

    Oudadesse, H.; Derrien, A.C.; Lucas-Girot, A.; Martin, S.; Cathelieau, G.

    2007-01-01

    Bony grafts are used as a filling biomaterial for defective bone. The introduction of new range of synthetic materials offers to surgeons additional possibilities to avoid virus transmission risks by using natural grafts in bony surgery. In this work, two materials, synthetic calcium carbonate and composite aluminosilicate/calcium phosphate were synthesized by an original method and experimented 'in vivo' as biomaterials for bony filling. Extracted biopsies were studied by several physico chemical and biological methods. The aim was to evaluate the kinetic resorption and bioconsolidation of these materials. We focused on the bioconsolidation between implant and bone by realising cartographies from the implant to the bone and on the calcification mechanism by determination of the origin of Ca and Sr responsible of the neo-formed bone. Neutron activation analysis (NAA), radiotracers 45 Ca* and 85 Sr* and proton-induced X-ray emission (PIXE) were used. Concerning the synthetic calcium carbonate, results show that twelve months after implantation, the mineral composition of implant becomes similar to that of the mature bone. The neoformed bone is composed with Ca and Sr coming from the organism when the Ca and Sr of the implant were progressively eliminated. Concerning the composite geopolymer/calcium phosphate, PIXE and histological studies reveal the intimate links between the bone and the implant starting with the first month after implantation. (author)

  2. Radiographic Study on the Bony Changes of Mandibular Condyle Head in Temporomandibular Disorder Patients

    International Nuclear Information System (INIS)

    Park, Moo Soon; You, Dong Soo

    1989-01-01

    The author has studied radiographic bony changes of mandibular condyle head in temporomandibular disorder patients using Oblique lateral transcranial projection, Orthopantomography, and Tomography. The bony change types and the frequencies of occurrence and the incidences of bony changes in three different radiographic techniques were examined. The coincidences of body change types between the Oblique lateral transcranial projection and the lateral part of Tomogram, the Orthopantomogram and the medial part of Tomogram were also examined. The results were as follows: 1. The mean age of patients was 31.7 years and under 40 years were 24 patients, women were 27 patients, men were 4 patients. 2. The observable cases of bony changes in all three radiographic techniques were 19 cases (50%) of 38 cases and the observable cases of bony changes in only Tomography were 5 cases (13.2%). 3. The most frequent radiographic bony change type was osteophyte and next orders were flattening, erosion, concavity. 4. The positional incidences of bony changes in Tomogram were 31 cases in lateral part and 27 cases in central part. 5. The coincidence of bony change types between the oblique lateral transcranial projection and the lateral part of Tomogram was 80%, and the coincidence between the Orthopantomogram and the medial part of Tomogram was 76.9%.

  3. Condylar bony changes in patients with temporomandibular disorders: a CBCT study

    Energy Technology Data Exchange (ETDEWEB)

    Nah, Kyung Soo [Dept. of Oral and Maxillofacial Radiology, School of Dentistry, Pusan National University, Yangsan (Korea, Republic of)

    2012-09-15

    Diagnosis of osteoarthritis most commonly depends on clinical and radiographic findings. The present study attempted to observe the bony changes in temporomandibular joint (TMJ) patients from all age groups. The first-visit clinical records and cone beam computed tomography (CBCT) data of 440 TMJs from 220 consecutive TMJ patients were reviewed retrospectively. The most frequent condylar bony change observed was sclerosis (133 joints, 30.2%) followed by surface erosion (129 joints, 29.3%), flattening of the articular surface (112 joints, 25.5%), and deviation in form (58 joints, 13.2%), which included 33 TMJs in a cane-shape, 16 with a lateral or medial pole depression, 6 with posterior condylar surface flattening, and 3 with a bifid-shaped condyle. Fifty-three joints (12.0%) showed hypoplastic condyles but only 1 joint showed hyperplasia. Osteophyte was found in 35 joints (8.0%) and subcortical cyst in 24 joints (5.5%), 5 of which had surface erosion as well. One hundred nineteen joints (27.0%) had only one kind of condylar bony change, 66 joints (15.0%) had two, 52 joints (11.8%) had three, 12 joints (5.0%) had four, and 6 joints (1.4%) had five kinds of condylar bony changes at the same time. Eighty-five (65.9%) of 129 joints with surface erosion had pain recorded at the chief complaint. With more widespread use of CBCT, more specific or detailed guidelines for osteoarthritis are needed.

  4. Condylar bony changes in patients with temporomandibular disorders: a CBCT study

    International Nuclear Information System (INIS)

    Nah, Kyung Soo

    2012-01-01

    Diagnosis of osteoarthritis most commonly depends on clinical and radiographic findings. The present study attempted to observe the bony changes in temporomandibular joint (TMJ) patients from all age groups. The first-visit clinical records and cone beam computed tomography (CBCT) data of 440 TMJs from 220 consecutive TMJ patients were reviewed retrospectively. The most frequent condylar bony change observed was sclerosis (133 joints, 30.2%) followed by surface erosion (129 joints, 29.3%), flattening of the articular surface (112 joints, 25.5%), and deviation in form (58 joints, 13.2%), which included 33 TMJs in a cane-shape, 16 with a lateral or medial pole depression, 6 with posterior condylar surface flattening, and 3 with a bifid-shaped condyle. Fifty-three joints (12.0%) showed hypoplastic condyles but only 1 joint showed hyperplasia. Osteophyte was found in 35 joints (8.0%) and subcortical cyst in 24 joints (5.5%), 5 of which had surface erosion as well. One hundred nineteen joints (27.0%) had only one kind of condylar bony change, 66 joints (15.0%) had two, 52 joints (11.8%) had three, 12 joints (5.0%) had four, and 6 joints (1.4%) had five kinds of condylar bony changes at the same time. Eighty-five (65.9%) of 129 joints with surface erosion had pain recorded at the chief complaint. With more widespread use of CBCT, more specific or detailed guidelines for osteoarthritis are needed.

  5. Conservative Treatment for Bony Healing in Pediatric Lumbar Spondylolysis.

    Science.gov (United States)

    Sakai, Toshinori; Tezuka, Fumitake; Yamashita, Kazuta; Takata, Yoichiro; Higashino, Kosaku; Nagamachi, Akihiro; Sairyo, Koichi

    2017-06-15

    A retrospective review of prospectively collected data. The aim of this study was to investigate recent outcomes of conservative treatment for bony healing in pediatric patients with lumbar spondylolysis (LS) and to identify the problems that need to be resolved. Several diagnostic and therapeutic techniques for LS have been developed recently, leading to better outcomes for bony healing. Overall, 63 consecutive pediatric patients (53 boys and 10 girls) with LS (average age: 13.8 years; range: 6-17 years) were analyzed. Diagnosis and staging (very early, early, progressive, and terminal) were based on multidetector computed tomography (CT) scans and magnetic resonance imaging (MRI). For all patients except those with terminal-stage pars defect, conservative treatment included rest, avoidance of sports, and the use of a thoraco-lumbo-sacral-type trunk brace. Follow-up MRI was performed monthly. When the signal changes resolved, CT scans were obtained to assess bony healing. Three patients dropped out during the study period. A total of 60 patients were included (50 boys and 10 girls) in this study (follow-up rate: 95.2%), with 86 instances of LS (very early: 36, early: 16, progressive: 15, terminal: 19) in 65 laminae. In the very early stage, the bony healing rate was 100%, and average treatment period was 2.5 months (range: 1-7 months). In the early stage, the bony healing rate was 93.8%, and the average treatment period was 2.6 months (range: 1-6 months). In the progressive stage, the bony healing rate was 80.0%, and the average treatment period was 3.6 months (range: 3-5 months). The average overall recurrence rate was 26.1%. All patients showing recurrence eventually achieved bony healing. High bony healing rates and short treatment periods were observed with conservative treatment in pediatric patients with LS. However, the recurrence rates were relatively high. This issue should be targeted in future studies. 2.

  6. Bone bonding at natural and biomaterial surfaces.

    Science.gov (United States)

    Davies, John E

    2007-12-01

    Bone bonding is occurring in each of us and all other terrestrial vertebrates throughout life at bony remodeling sites. The surface created by the bone-resorbing osteoclast provides a three-dimensionally complex surface with which the cement line, the first matrix elaborated during de novo bone formation, interdigitates and is interlocked. The structure and composition of this interfacial bony matrix has been conserved during evolution across species; and we have known for over a decade that this interfacial matrix can be recapitulated at a biomaterial surface implanted in bone, given appropriate healing conditions. No evidence has emerged to suggest that bone bonding to artificial materials is any different from this natural biological process. Given this understanding it is now possible to explain why bone-bonding biomaterials are not restricted to the calcium-phosphate-based bioactive materials as was once thought. Indeed, in the absence of surface porosity, calcium phosphate biomaterials are not bone bonding. On the contrary, non-bonding materials can be rendered bone bonding by modifying their surface topography. This paper argues that the driving force for bone bonding is bone formation by contact osteogenesis, but that this has to occur on a sufficiently stable recipient surface which has micron-scale surface topography with undercuts in the sub-micron scale-range.

  7. Bony ankylosis following thermal and electrical injury

    Energy Technology Data Exchange (ETDEWEB)

    Balen, P.F.; Helms, C.A. [Dept. of Radiology, Duke University Medical Center, Durham, NC (United States)

    2001-07-01

    Objective. Bony ankylosis has been described following trauma, paralysis, psoriasis, Reiter's syndrome, ankylosing spondylitis, juvenile chronic arthritis and rheumatoid arthritis. Reports of bony ankylosis following thermal and electrical injury are limited.Design and patients. Thirteen cases of burn-related joint ankylosis in four patients are presented.Conclusion. Patients with burns from thermal or electrical injury may develop bony ankylosis among other radiographic manifestations. This bony ankylosis may result either from bridging extra-articular heterotopic ossification with preservation of the underlying joint or from intra-articular fusion due to joint destruction. (orig.)

  8. Relationship of bony trabecular characteristics and age to bone mass

    International Nuclear Information System (INIS)

    Choi, Dong Hoon; Song, Young Han; Yoon, Young Nam; Lee, Wan; Lee, Byung Do

    2006-01-01

    Bony strength is dependent on bone mass and bony structure. So this study was designed to investigate the relationship between the bone mass and bony mass and bony trabecular characteristics. Study subjects were 51 females (average age 68.6 years) and 20 males (average age 66.4 years). Bony mineral density (BMD, grams/cm 2 ) of proximal femur was measured by a dual energy X-ray absorptiometry (DEXA). Regions of interest (ROIs) were selected from the digitized radiographs of proximal femur. A customized computer program processed morphologic operations (MO) of ROIs. 44 skeletal variables of MO were calculated from ROIs on the Ward's triangle and greater trochanter of femur. WHO BMD classes were predicted by MO variables of the same ROI. Classification and Regression Tree analysis was used for calculating weighted kappa values, sensitivity and specificity of MO. The discriminating factors of morphologic operation were branch point, branch point [per cm sq]. Age also played important role in distinguishing osteoporotic classes. The sensitivity of MO at Ward's triangle and Greater Trochanter was 91.8%, 65.6%, respectively. The specificity of MO was 100% at Ward's triangle and Greater Trochanter. Bony trabecular characteristics obtained using radiological bone morphometric analysis seem to be related to bone mass

  9. Bony Regeneration of the Sella after Transsphenoidal Pituitary Surgery.

    Science.gov (United States)

    Yahia-Cherif, Mehdi; Delpierre, Isabelle; Hassid, Sergio; De Witte, Olivier

    2016-04-01

    The purpose of this study is to demonstrate the possible bony regrowth of the sella after transsphenoidal surgery without any intraoperative sellar reconstruction. Radiologic findings of the sella were reviewed in patients with pituitary tumors treated by transsphenoidal surgery. In 17 patients who had postoperative cranial computed tomography scans, bony regeneration of the sellar floor was evaluated by comparing immediate and late postoperative scans. The bony opening reduction was measured in transverse and sagittal planes. The median bony opening diameter in the transverse plane was 8.8 mm (interquartile range [IQR] 5.7-11.4) on the first scan and 4.2 mm (IQR 0.8-6.8) on the second scan. In the sagittal plane, it was 4.8 mm (IQR 1.8-6.8) on the first scan and 2.9 mm (IQR 1.6-3.9) on the second scan. These changes occurred in a median time of 36 months (IQR 22-42). There was a statistically significant decrease of the bony opening diameters in both the transverse and sagittal planes (P transsphenoidal pituitary surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Study of bony trabecular characteristics using bone morphometry and micro-CT

    International Nuclear Information System (INIS)

    Song, Young Han; Lee, Wan; Lee, Chang Jin; Ji, Jung Hyun; Lee, Byung Do

    2007-01-01

    The research was done to investigate the effectiveness of 2D bony morphometry and microstructure of micro-computed tomography (micro-CT) on the osteoporotic bony change. We performed the bone morphometric analysis of proximal femur in ovariectomized rabbits with BMD and micro-CT examination. Twenty-one female (Newzeland, about 16 weeks old, 2.9-3.4 kg) rabbits were used. Three rabbits were sacrificed on the day when experiment began (Basline). The remaining 18 rabbits were divided into two groups. One group was ovariectomized bilaterally (OVX) and the other animals were subjected to sham operation (Sham). Bone specimens were obtained from the right and left femur of sacrificed rabbits. At intervals of 1,2,3,5,6 months respectively, BMD tests were performed on the proximal on the proximal femur by using PIXImus 2 (GE Lunar Co. USA), 2-dimensional bone morphometric analysis by custom computer program and 2D / 3D bone structure analysis by micro-CT (Skyscan1072, Antwerpen, Belgium). Statistical analysis was carried out for the correlation between bone morphometry, micro-CT and BMD. BV/TV, Tb.Th, Tb.N of micro-CT parameters showed higher values in sham group than OVX group. N.Nd/Ar.RI, N.NdNd, N.NdTm, N. TmTm, PmB/Ar.RI, 3-D BoxSlope of 2D morphometric parameters showed higher values in Sham group than OVX group. The micro-CT parameters of Tb.Sp. Tb.N were statistically significant correlated with BMD respectively. Several 2D morphometric parameters were statistically significant correlated with BMD respectively. Several parameters of 2D bony morphometry and micro-CT showed effective aspects on the osteoporotic bony change

  11. Phylogenetic classification of bony fishes.

    Science.gov (United States)

    Betancur-R, Ricardo; Wiley, Edward O; Arratia, Gloria; Acero, Arturo; Bailly, Nicolas; Miya, Masaki; Lecointre, Guillaume; Ortí, Guillermo

    2017-07-06

    Fish classifications, as those of most other taxonomic groups, are being transformed drastically as new molecular phylogenies provide support for natural groups that were unanticipated by previous studies. A brief review of the main criteria used by ichthyologists to define their classifications during the last 50 years, however, reveals slow progress towards using an explicit phylogenetic framework. Instead, the trend has been to rely, in varying degrees, on deep-rooted anatomical concepts and authority, often mixing taxa with explicit phylogenetic support with arbitrary groupings. Two leading sources in ichthyology frequently used for fish classifications (JS Nelson's volumes of Fishes of the World and W. Eschmeyer's Catalog of Fishes) fail to adopt a global phylogenetic framework despite much recent progress made towards the resolution of the fish Tree of Life. The first explicit phylogenetic classification of bony fishes was published in 2013, based on a comprehensive molecular phylogeny ( www.deepfin.org ). We here update the first version of that classification by incorporating the most recent phylogenetic results. The updated classification presented here is based on phylogenies inferred using molecular and genomic data for nearly 2000 fishes. A total of 72 orders (and 79 suborders) are recognized in this version, compared with 66 orders in version 1. The phylogeny resolves placement of 410 families, or ~80% of the total of 514 families of bony fishes currently recognized. The ordinal status of 30 percomorph families included in this study, however, remains uncertain (incertae sedis in the series Carangaria, Ovalentaria, or Eupercaria). Comments to support taxonomic decisions and comparisons with conflicting taxonomic groups proposed by others are presented. We also highlight cases were morphological support exist for the groups being classified. This version of the phylogenetic classification of bony fishes is substantially improved, providing resolution

  12. Canine hip dysplasia: significance of early bony spurring

    International Nuclear Information System (INIS)

    Morgan, J.P.

    1987-01-01

    It is the purpose of this study to call attention to new bone production that often occurs early in the sequence of pathological changes associated with canine hip dysplasia. New bone production extending to bony remodeling, as well as femoral head subluxation, both occur in the sequence of pathologic changes associated with canine hip dysplasia. Subluxation is considered primary, while osteoarthrosis is a secondary feature, and both are used in the diagnosis of canine hip dysplasia. This report concerns the significance of the presence of a solitary bony osteophyte, or spur, that is frequently evident on the caudal aspect of the femoral neck as viewed on the conventional ventrodorsal projection. This report utilizes findings from pelvic radiographs of 605 dogs (five breeds). There was a greater frequency (54%)of this bony change in cases diagnosed radiographically as dysplastic than in cases diagnosed as normal(15%).Thus, it is suggested that this minimal radiographic change can be used as an indicator of early canine hip dysplasia, especially in the absence of subluxation of the femoral head

  13. Bony morphology of the hip in professional ballet dancers compared to athletes.

    Science.gov (United States)

    Mayes, Susan; Ferris, April-Rose; Smith, Peter; Garnham, Andrew; Cook, Jill

    2017-07-01

    To compare hip bony morphology between ballet dancers and a sporting control group and to determine the relationship with hip pain. Thirty-three professional ballet dancers and 33 age- and sex-matched athletes completed questionnaires, including the Copenhagen Hip and Groin Outcome Score (HAGOS), and underwent clinical testing and 3.0-T magnetic resonance imaging to measure acetabular coverage with lateral centre edge angles, femoral head-neck junction concavity with alpha angles at anterior and superior positions, femoral neck-shaft angles, and acetabular version angles. Bony morphological measures fell within normal ranges. Dancers had higher neck-shaft angles (dancers 134.6 ± 4.6°/athletes130.8 ± 4.7°, p = 0.002), lower acetabular version angles (13.5 ± 4.7°/17.1 ± 4.7°, p = 0.003), lower superior alpha angles (38.9 ± 6.9°/46.7 ± 10.6°, p ballet dancers have hip bony morphology that differentiates them from athletes. Hip pain correlated poorly with bony morphology. • Ballet dancers have hip bony morphology that may allow extreme hip motion. • Morphological parameter means fell within normal reference intervals in dancers. • Bony morphology correlates poorly with hip pain. • The risk of hip injury due to abnormal morphology requires prospective studies.

  14. Arthroscopic Anterior Shoulder Stabilization With Incorporation of a Comminuted Bony Bankart Lesion

    OpenAIRE

    Lansdown, Drew; Bernardoni, Eamon D.; Cotter, Eric J.; Romeo, Anthony A.; Verma, Nikhil N.

    2017-01-01

    Bony Bankart lesions are a common finding in patients with anterior glenohumeral dislocation. Although there are no defined guidelines, small bony Bankart fractures are typically treated arthroscopically with suture anchors. The 2 main techniques used are double- and single-row suture anchor stabilization, with debate over superiority. Biomechanical studies have shown improved reduction and stabilization with the double-row over the single-row suture anchor technique; however, this has not be...

  15. Algodystrophy in children and young adults with isotopic bony hypofixation. A propos of 5 observations

    International Nuclear Information System (INIS)

    Doury, P.; Pattin, S.; Eulry, F.; Granier, R.; Gaillard, F.

    1986-01-01

    The authors report 5 observations of young adults 3 teen-agers and 2 children suffering from algodystrophy, and in whom isotopic exploration of the skeleton disclosed a clear bony hypofixation during the entire evolution. These observations confirm their 1981 work concerning a young adult suffering from algodystrophy with isotopic bony hypofixation. Recent Canadian and American studies emphasize also the frequency of isotopic hypofixation in children algodystrophy. It seems, therefore, that isotopic bony hypofixation (linked perhaps to a decreased blood flow), is rather specific of algodystrophy in young subjects [fr

  16. Incidence of dehiscence of the bony roof of the superior semicircular canal by CT imaging

    International Nuclear Information System (INIS)

    Watanabe, Akira

    2003-01-01

    Dehiscence of the bony roof of the superior semicircular canal (SSCC) is rare, but it has been recognized by otologists since Minor et al first described superior canal dehiscence syndrome (SCDS). In this study, dehiscence of the bony roof of SSCC was incidentally detected in three patients with benign paroxysmal positional vertigo out of 49 serial patients with vertigo and dizziness by multi-slice computed tomography. Although detection of dehiscence of the SSCC by ultra-high-resolution CT imaging of the temporal bones has been required for a diagnosis of SCDS, this study showed that dehiscence of the bony roof of the SSCC can be an incidental finding and therefore is not specific for SCDS. (author)

  17. Wind rotor power station BONI-ShHV

    International Nuclear Information System (INIS)

    Bolotov, A.V.

    1999-01-01

    Wind rotor power station (WRPS) BONI-ShHV has following advantages : the increase of installation stability by rise of wind velocity and rotation speed of rotor due to gyroscopic effect; the absence noise and vibration; the safety for birds and animals; ability of compact installation and creation of series of wind power dams with higher capacity; the simplicity and fast assembling and putting into operation. The price of 1 k W of installing capacity is lower about 2.5-3 times compare to usual WRPS due to simple kinematic scheme. WRPS has high specific output of electrical energy due to use of low and long existing wind velocity and due to short storms, giving greater power. It has ability to be replayed when average annual wind velocity is above 5.5 m/s in comparison with propeller WRPS, which are never repaying. WRPS BONI-ShHV are made on the plants of Republic of Kazakhstan, and tested in wind velocity range up 45 m/s, have experience of 3 years of operation, showing their reliability and effectiveness. The repayment period of individual WRPS BONI-0.5/6 ShHV is from 10 month to 1 year depending on average annual velocity

  18. [Inconformity between soft tissue defect and bony defect in incomplete cleft palate].

    Science.gov (United States)

    Zhou, Xia; Ma, Lian

    2014-12-01

    To evaluate the inconformity between soft tissue defect and bony defect by observing the cleft extent of palate with complete secondary palate bony cleft in incomplete cleft palate patient. The patients with incomplete cleft palate treated in Hospital of Stomatology Peking University from July 2012 to June 2013 were reviewed, of which 75 cases with complete secondary palate bony cleft were selected in this study. The CT scan and intraoral photograph were taken before operation. The patients were classified as four types according to the extent of soft tissue defect. Type 1: soft tissue defect reached incisive foremen region, Type 2 was hard and soft cleft palate, Type 3 soft cleft palate and Type 4 submucous cleft palate. Type 1 was defined as conformity group (CG). The other three types were defined as inconformity group (ICG) and divided into three subgroups (ICG-I), (ICG-II) and (ICG-III). Fifty-seven patients were in ICG group, and the rate of inconformity was 76% (57/75). The percentage of ICG-I, ICG-II and ICG-III was 47% (27/57), 23% (13/57) and 30% (17/57), respevtively. There are different types of soft tissue deformity with complete secondary palate bony cleft. The inconformity between soft tissue and hard tissue defect exits in 3/4 of isolated cleft palate patients.

  19. Bony defect of palate and vomer in submucous cleft palate patients.

    Science.gov (United States)

    Ren, S; Ma, L; Zhou, X; Sun, Z

    2015-01-01

    The aim of this study was to visualize bony defects of the palate and vomer in submucous cleft palate patients (SMCP) by three-dimensional (3D) computed tomography (CT) reconstruction and to classify the range of bony defects. Forty-eight consecutive non-operated SMCP patients were included. Diagnosis was based on the presence of at least one of three classical signs of SMCP: bifid uvula, a translucent zone in the midline of the soft palate, and a palpable 'V' notch on the posterior border of the bony palate. Patients were imaged using spiral CT. 3D reconstruction models were created of the palate and vomer. The sagittal extent of the bony cleft in SMCP was classified into four types: type I, no V-shaped hard palate cleft (8.3%); type II, cleft involving the partial palate (43.8%); type III, cleft involving the complete palate and extending to the incisive foramen (43.8%); type IV, cleft involving the complete palate and the alveolar bone (4.2%). The extent of the vomer defect was classified into three types: type A, vomer completely fused with the palate (8.3%); type B, vomer partially fused with the palate (43.8%); type C, vomer not fused with the palate up to the incisive foramen (47.9%). Significant variability in hard palate defects in SMCP is the rule rather than the exception. The association of velopharyngeal insufficiency with anatomical malformations may be complex. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Effects of platelet-rich fibrin on healing of intra-bony defects treated with anorganic bovine bone mineral.

    Science.gov (United States)

    Sezgin, Yasemin; Uraz, Ahu; Taner, I Levent; Çulhaoğlu, Rana

    2017-01-26

    Anorganic bovine bone mineral (ABBM) is extensively used in the treatment of intra-bony defects. Platelet-rich fibrin (PRF) is a new-generation platelet concentrate with a simplified technique. Although certain studies have reported the use of PRF in the treatment of intra-bony defects, to date, none of them have evaluated its additive effects with ABBM. Therefore, a randomised, split-mouth clinical trial was conducted to compare healing of intra-bony defects treated with an ABBM-PRF combination with healing of those treated with ABBM alone. By using a split-mouth design, 15 paired intra-bony defects were randomly treated with either ABBM alone (control group) or ABBM-PRF combination (test group). Following clinical parameters and radiographical measurements were recorded at baseline and 6 months after treatment: plaque index (PI), gingival index (GI), probing depth (PD), gingival recession (GR), clinical attachment level (CAL), vertical bone loss, depth of defect and defect angle. Preoperative clinical and radiographical measurements were similar for the test and control groups. Statistically significant reductions in GI, PD, CAL, vertical bone loss, depth of intra-bony defect and widening of defect angle were detected after treatment in both groups. With respect to inter-group analysis, gain in CAL was significantly greater in the test group than in the control group, whereas no inter-group differences were observed in any other parameter. The results of this study indicate that both therapies are effective in the treatment of intra-bony defects.

  1. Between Organism and Sky: Oscar Bony, 1965-1976

    Directory of Open Access Journals (Sweden)

    Daniel Quiles

    2014-06-01

    Full Text Available Oscar Bony was a key figure in the generation of avant-garde artists who famously broke with the Instituto Torcuato Di Tella in the wake of censorship at Experiencias ’68. He was also the official photographer for RCA’s affiliate record label in Argentina between 1967 and 1973, producing publicity for a new wave of rock n’ roll bands and solo popular music acts including Los Gatos and Arco Iris. Attending to key phases in his artistic oeuvre as well as close readings of his expertly crafted popular images, this article attempts to bridge these seemingly irreconcilable aspects of Bony’s practice. At first glance, his rock photography, known as el estilo Bony, has little relation to his art, and is perhaps even its political antithesis: “creative” work in the service of a top-down business model. Yet a closer look at both endeavors yields a lasting interplay between flesh and concept—at the grain of the work, a dialectic between incontrovertible index and crafted, calculated image—that was the artist’s central preoccupation in the fraught decade between the military coups. As such, Bony provides an opportunity to recover a category often absent from the Argentine art of this moment: the body, factual and libidinal.

  2. Bony sequestrum: A radiologic review

    Energy Technology Data Exchange (ETDEWEB)

    Jennin, Felicie; Bousson, Valerie; Parlier, Caroline; Jomaah, Nabil; Khanine, Vanessa; Laredo, Jean-Denis [Lariboisiere Hospital, Department of Radiology, Paris (France)

    2011-08-15

    According to a pathological definition, a bony sequestrum is defined as a piece of devitalized bone that has been separated from the surrounding bone during the process of necrosis. However, the radiological definition of a sequestrum is different and refers to an image of calcification visible within a lucent lesion, completely separated from the surrounding bone, without referring to the vascular status and histological nature of the calcified tissue. The term ''button sequestrum'' has been used in calvarial lesions. The prototype conditions that may present with a bony sequestrum are osteomyelitis and skeletal tuberculosis. Other conditions such as radiation necrosis, eosinophilic granuloma, metastatic carcinoma, primary lymphoma of bone, aggressive fibrous tumors may also manifest as osteolytic lesions containing a sequestrum. In addition, some primary bone tumors produce a matrix that may mineralize and sometimes simulate a bone sequestrum. These include osteoid tumors (osteoid osteoma, osteoblastoma), cartilaginous tumors (chondroma and chondroblastoma), lipomatous tumors (lipoma), and benign fibrous tumors (fibromyxoma, myxoma, and desmoplastic fibroma). Therefore, various conditions may present at imaging as a small area of osteolysis containing central calcifications. However, a careful analysis of the sequestrum as well as the associated clinical and radiological findings often enables to point toward a limited number of conditions. (orig.)

  3. Observations on the bony bridging of the jugular foramen in man.

    Science.gov (United States)

    Dodo, Y

    1986-02-01

    The anatomical nature and pattern of incidence of bony bridging of the jugular foramen was investigated using 64 fetal crania aged nine months to term and 222 adult crania of Japanese. In addition, the region of the jugular foramen of an adult cadaver was carefully dissected in order to clarify the relationship between the cranial nerves passing through the jugular foramen and the intrajugular processes of the jugular foramen. The general conclusions concerning the anatomical nature of the bony bridging of the jugular foramen were as follows. (1) The intrajugular process of the temporal bone is situated posterior to the triangular depression (as described in Gray's Anatomy) of the petrous part. (2) The bony bridging of the jugular foramen is established by the contact of the intrajugular process of the temporal bone with the bony process of the occipital bone projecting either from just above the hypoglossal canal (Type I) or from posterior to the hypoglossal canal (Type III). (3) If both the processes of the occipital bone reach the intrajugular process of the temporal bone simultaneously, the jugular foramen is divided into three compartments. (4) In the case of Type I bridging, the anteromedial compartment transmits the glossopharyngeal nerve, while the posterolateral compartment gives passage to the vagus nerve, the accessory nerve and the internal jugular vein. (5) In the case of Type II bridging, the anteromedial compartment contains the glossopharyngeal, vagus and accessory nerves, and the posterolateral compartment transmits the internal jugular vein. (6) When tripartite division of the jugular foramen occurs, the anteromedial compartment transmits the glossopharyngeal nerve, the middle compartment contains the vagus and accessory nerves, and the posterolateral compartment transmits the internal jugular vein. Concerning the pattern of incidence of jugular foramen bridging in the Japanese fetal and adult cranial series, this is similar to that of the bony

  4. Bony Calvarium as the Sole Site ofMetastases in Squamous Cell Carcinomaof the Uterine Cervix

    Directory of Open Access Journals (Sweden)

    Mohammad Mohammadianpanah

    2010-10-01

    Full Text Available Isolated skeletal metastasis to the bony calvarium is extremely rare in patients with squamous cell carcinoma of the uterine cervix. We describe the clinical and imaging findings in a case of squamous cell carcinoma of the uterine cervix with metastases tothe bony calvarium as the sole site of metastasis. The patient was a 65-year-old woman with squamous cell carcinoma of the uterine cervix, FIGO stage IIIb, whose initial treatement was chemoradiation therapy. After 22 sessions of external-beam radiation,she developed headaches. On physical examination she had skull bone tenderness. On plain skull X-ray, there were osteolytic bony lesions. Brain MRI showed multiple enhancing skull bone metatstses. Eventually, a whole body bone scintigraphy revealed isolated diffuse increased activity in the bony calvarium. In the literature review, wefound only three similar cases of cervical cancer with scalp metastases and involvement of the bony calvarium.

  5. Airway Obstruction and the Unilateral Cleft Lip and Palate Deformity: Contributions by the Bony Septum.

    Science.gov (United States)

    Friel, Michael T; Starbuck, John M; Ghoneima, Ahmed M; Murage, Kariuki; Kula, Katherine S; Tholpady, Sunil; Havlik, Robert J; Flores, Roberto L

    2015-07-01

    Patients with unilateral cleft lip and palate (CLP) deformities commonly develop nasal airway obstruction, necessitating septoplasty at the time of definitive rhinoplasty. We assessed the contribution of the bony septum to airway obstruction using computed tomography (CT) and cone beam CT (CBCT). A 2-year retrospective review of all subjects with unilateral CLP who underwent CBCT imaging (n = 22) and age-matched controls (n = 9) who underwent CT imaging was conducted. Control CT scans were used to determine the segment of nasal septum comprised almost entirely of bone. The CBCT of the nasal airway was assessed using Dolphin software to determine the contribution of the bony septum to septal deviation and airway obstruction. The nasal septum posterior to the midpoint between anterior and posterior nasal spine is comprised of 96% bone. The nasal airway associated with this posterior bony segment was 43.1% (P < 0.001) larger by volume on the non-cleft side in patients with unilateral CLP. The average septal deviation within the posterior bony segment was 5.4 mm, accounting for 74.4% of the maximal deviation within the nasal airway. The average airway stenosis within the posterior bony nasal airway was 0.45 mm (0-2.2 mm). In patients with unilateral CLP, the bony nasal septum can demonstrate significant deviation and airway stenosis. Surgeons should consider a bony septoplasty in their treatment algorithm in unilateral CLP patients who have reached skeletal maturity.

  6. The paediatric wrist revisited - findings of bony depressions in healthy children on radiographs compared to MRI

    International Nuclear Information System (INIS)

    Avenarius, Derk M.F.; Eldevik, Petter; Ording Mueller, Lil-Sofie; Owens, Catherine M.; Rosendahl, Karen

    2012-01-01

    The presence of erosions is used for diagnosis and monitoring of disease activity in juvenile idiopathic arthritis (JIA). Assessment of carpal bone erosions in children is challenging due to lack of normal references. To define normal appearances of bony depressions in the wrist on radiographs and MRI. MRI and radiography of the wrist were performed in 88 healthy children, 5-15 years of age. We assessed the number of bony depressions within the carpals/proximal metacarpals on both modalities, separately and combined. A total of 75 carpal depressions were identified on radiography compared to 715 on MRI. The number of bony depressions identified radiographically showed no statistically significant difference across age-groups. Within the metacarpals, there was no significant difference between bony depressions identified by MRI or radiography, except at the bases of the second metacarpal. Bony depressions that resemble erosions are normal findings in the wrist in children. MRI identifies more depressions than radiographs in the carpus. Some bony depressions occur at typical locations and should be accounted for when assessing the wrist in JIA to avoid overstaging. (orig.)

  7. Comparison of megavoltage position verification for prostate irradiation based on bony anatomy and implanted fiducials

    International Nuclear Information System (INIS)

    Nederveen, Aart J.; Dehnad, Homan; Heide, Uulke A. van der; Moorselaar, R. Jeroen A. van; Hofman, Pieter; Lagendijk, Jan J.W.

    2003-01-01

    Purpose: The patient position during radiotherapy treatment of prostate cancer can be verified with the help of portal images acquired during treatment. In this study we quantify the clinical consequences of the use of image-based verification based on the bony anatomy and the prostate target itself. Patients and methods: We analysed 2025 portal images and 23 computed tomography (CT) scans from 23 patients with prostate cancer. In all patients gold markers were implanted prior to CT scanning. Statistical data for both random and systematic errors were calculated for displacements of bones and markers and we investigated the effectiveness of an off-line correction protocol. Results: Standard deviations for systematic marker displacement are 2.4 mm in the lateral (LR) direction, 4.4 mm in the anterior-posterior (AP) direction and 3.7 mm in the caudal-cranial direction (CC). Application of off-line position verification based on the marker positions results in a shrinkage of the systematic error to well below 1 mm. Position verification based on the bony anatomy reduces the systematic target uncertainty to 50% in the AP direction and in the LR direction. No reduction was observed in the CC direction. For six out of 23 patients we found an increase of the systematic error after application of bony anatomy-based position verification. Conclusions: We show that even if correction based on the bony anatomy is applied, considerable margins have to be set to account for organ motion. Our study highlights that for individual patients the systematic error can increase after application of bony anatomy-based position verification, whereas the population standard deviation will decrease. Off-line target-based position verification effectively reduces the systematic error to well below 1 mm, thus enabling significant margin reduction

  8. Computed tomographic features of the bony canal of the cochlear nerve in pediatric patients with unilateral sensorineural hearing loss

    International Nuclear Information System (INIS)

    Kono, Tatsuo

    2008-01-01

    The aim of this study was to evaluate the diameters of the various bony canals of the inner ear in patients with sensorineural hearing loss (SNHL) and establish criteria for detecting hypoplasia of the bony canal of the cochlear nerve. Measurements obtained in 118 patients without inner ear malformations among 160 patients with unilateral SNHL were analyzed. The diameters of the internal auditory canal and the bony canals of the cochlear, vestibular, and facial nerves were measured on transverse or coronal computed tomographic images. Mean values (±standard deviation (SD)) were compared between the affected and unaffected ears, and statistical analysis was done. The diameter of the bony canal of the cochlear nerve was significantly smaller in affected ears than in unaffected ears (P<0.01). The affected ears could be divided into groups with (72 ears) and without (46 ears) bony canal stenosis. Most (60%) of the patients with unilateral SNHL showed a significant difference in the diameters of the bony canals of the cochlear nerve between the affected and unaffected sides; moreover, the mean value was significantly smaller in affected ears. The diameter of <1.7 mm on transverse images or <1.8 mm on coronal images suggests hypoplasia. (author)

  9. Blunt chest trauma: bony injury in the thorax.

    Science.gov (United States)

    Zreik, Nasri H; Francis, Irene; Ray, Arun; Rogers, Benedict A; Ricketts, David M

    2016-02-01

    The management of blunt chest trauma is an evolving concept with no clear current guidelines. This article explores the bony injuries associated with this, focusing on rib fractures and flail segments and the themes around investigation and best management.

  10. Quantitative computed tomography as a test of endurance for evaluation of bony plates

    International Nuclear Information System (INIS)

    Melo Filho, E.V.; Costa, L.A.V.S.; Oliveira, D.C.; Freitas, P.M.C.; Teixeira, M.W.; Costa, F.S.

    2012-01-01

    Quantitative computed tomography was used to determine the radiodensity of bony plates. The CT scans provided information regarding radiodensity of bony plates and allowed to verify the uniformity of bone mineral density in their scope. The proposed methodology should be considered as another tool for determining the resistance of these biomaterials. (author)

  11. Radiographic detection of artificial intra-bony defects in the edentulous area.

    Science.gov (United States)

    Van Assche, N; Jacobs, R; Coucke, W; van Steenberghe, D; Quirynen, M

    2009-03-01

    Since intra-bony pathologies might jeopardize implant outcome, their preoperative detection is crucial. In sixteen human cadaver bloc sections from upper and lower jaws, artificial defects with progressively increasing size (n=7) have been created. From each respective defect, analogue and digital intra-oral radiographs were taken, the latter processed via a periodontal filter and afterwards presented in black-white as well as in colour, resulting in three sets of 7 images per bloc section. Eight observers were asked to diagnosis an eventual defect on randomly presented radiographs, and at another occasion to rank each set based on the defect size. The clinicians were only able to identify a defect, when the junctional area was involved, except for bony pieces with a very homogeneous structure. For longitudinal evaluation of healing bone (e.g. after tooth extraction), colour digital images can be recommended. These observations indicate that intra-oral radiographs are not always reliable for the detection of any intra-bony defect.

  12. Impact of Bony Stress Injuries on Professional Basketball Performance

    Science.gov (United States)

    Khan, Moin; Madden, Kim; Rogowski, Joseph P.; Stotts, Jeff; Burrus, Matthew Tyrrell; Samani, Marisa; Sikka, Robby Singh; Bedi, Asheesh

    2017-01-01

    Objectives: Players in the National Basketball Association (NBA) subject their lower extremities to significant repetitive loading during the season as well as during off-season training. Little is known about the incidence and impact of lower extremity bony stress injuries in these athletes. Methods: Using the player injury database maintained by the NBA Players’ Association, all bony stress injuries from 1992 to May 2016 were identified. Those not involving the lower extremity were excluded from the study. Stress fractures and stress reactions were grouped together. Number of games missed due to the injury as well as player statistics including points per game (ppg), assists per game (apg), steals per game (spg), and blocks per game (bpg) were collected from two years prior to the injury to two years after the injury. Results: 76 lower extremity bony stress injuries were identified involving 75 different NBA players with an average player age of 25.4 ± 4.1 years. 55.3% (42/76) involved the foot, 21.1% (16/76) involved the ankle or fibula, 17.1% (13/76) involved the tibia, and 6.6% (5/76) involved either the knee or patella. The majority of injuries occurred in season 82.9% (63/76) with half of the injuries occurring within the first 6 weeks of the season. 38.2% (29/76) of these injuries were managed surgically. An average of 25.1 ± 21.3 games were missed. 19.7% (15/76) of patients who sustained a stress fracture also had a subsequent injury. 29.2% (21/76) of players were not able to return to professional basketball after the season in which the injury was sustained; however, those who were able to return to the same level of play did not see a significant change in performance as measured by ppg, apg, spg, or bpg when comparing the season prior to the injury and either one or two years after the injury. Stress injuries to the foot carried the worst prognosis, 57.1% (12/21) of those unable to return to professional basketball sustained such an injury

  13. Natural resources utilization by the Aweer in Boni-lungi and Dodori ...

    African Journals Online (AJOL)

    A study was conducted to record the utilization of Boni-Lungi and Dodori National Reserves by the Aweer community. Results indicate the procuring of a wide gamut of provisional, regulatory, cultural and supportive services from these reserves by the community ranging from wood forest products utilized in construction to ...

  14. A technique for the quantification of the 3D connectivity of thin articulations in bony sutures.

    Science.gov (United States)

    Maloul, Asmaa; Fialkov, Jeffrey; Hojjat, Seyed-Parsa; Whyne, Cari M

    2010-04-19

    The anatomy and development of cranial and facial sutures have been studied in detail using histological sections, 2D radiographs and more recently CT imaging. However, little attention has been paid to evaluating and quantifying the connectivity of these thin cortical bone articulations. More recent technological advances such as micro-CT imaging has the potential to be used to provide quantitative measurements of 3D connectivity in bony articulations. This study presents a new technique for quantifying the connectivity of bony projections inside cranial and facial sutures using a combination of skeletonization, thinning algorithms and 3D intensity mapping. The technique is demonstrated in five sutures through semi-automated analysis and image processing of microCT scans. In the sagittal, coronal and frontozygomatic sutures an average bone connectivity of 6.6-11.6% was found with multiple bony projections providing an interlocking structure between adjacent bones. Much higher bone connectivity was present in the zygomaticotemporal and zygomaticomaxillary sutures (22.7-37.4%) with few bony projections. This method combining microCT scanning and image processing techniques was successfully used to quantify the connectivity of thin bone articulations and allowed detailed assessment of sutural fusion in 3D. The wider application of this technique may allow quantification of connectivity in other structures, in particular fracture healing of long bones. Copyright 2009 Elsevier Ltd. All rights reserved.

  15. The relationship of transverse sinus stenosis to bony groove dimensions provides an insight into the aetiology of idiopathic intracranial hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Connor, S.E.J.; Stewart, V.R.; O' Flynn, E.A.M. [King' s College Hospital, Neuroradiology Department, Ruskin Wing, London (United Kingdom); Siddiqui, M.A. [Southern General Hospital, Institute of Neurological Sciences, Glasgow (United Kingdom)

    2008-12-15

    Transverse sinus tapered narrowings are frequently identified in patients with idiopathic intracranial hypertension (IIH); however, it remains unclear whether they are primary stenoses or whether they occur secondary to raised cerebrospinal fluid pressure. Computed tomographic venography demonstrates both the morphology of the venous system and the adjacent bony grooves so it may provide an insight into the aetiology of these transverse sinus stenoses. Tapered transverse sinus narrowings (>50%) were studied in 19 patients without IIH and 14 patients with IIH. Computed tomography vascular studies were reviewed and the dimensions of the venous sinuses and bony grooves at the sites of maximum and minimum transverse sinus area dimensions were recorded. There was demonstrated to be a strong correlation of bony groove height with venous sinus height at the largest portions of the transverse sinus in both IIH patients and non-IIH subjects as well as at the transverse sinus narrowing in non-IIH subjects. There was a discordant relationship between bony groove height and venous sinus height at the site of transverse sinus stenoses in IIH patients. In 5/23 IIH transverse sinus stenoses, the bony groove height was proportionate to that seen in non-IIH subjects. There were a further 8/23 cases where the small or absent sinus was associated with an absent bony groove. Transverse sinus tapered narrowings in subjects without IIH and in the majority of patients with IIH were associated with proportionately small or absent grooves, and these are postulated to be primary or fixed. Some patients with IIH demonstrate tapered transverse sinus stenoses with disproportionately large bony grooves, suggesting a secondary or acquired narrowing. This implies a varied aetiology for the transverse sinus stenoses of IIH. (orig.)

  16. The relationship of transverse sinus stenosis to bony groove dimensions provides an insight into the aetiology of idiopathic intracranial hypertension

    International Nuclear Information System (INIS)

    Connor, S.E.J.; Stewart, V.R.; O'Flynn, E.A.M.; Siddiqui, M.A.

    2008-01-01

    Transverse sinus tapered narrowings are frequently identified in patients with idiopathic intracranial hypertension (IIH); however, it remains unclear whether they are primary stenoses or whether they occur secondary to raised cerebrospinal fluid pressure. Computed tomographic venography demonstrates both the morphology of the venous system and the adjacent bony grooves so it may provide an insight into the aetiology of these transverse sinus stenoses. Tapered transverse sinus narrowings (>50%) were studied in 19 patients without IIH and 14 patients with IIH. Computed tomography vascular studies were reviewed and the dimensions of the venous sinuses and bony grooves at the sites of maximum and minimum transverse sinus area dimensions were recorded. There was demonstrated to be a strong correlation of bony groove height with venous sinus height at the largest portions of the transverse sinus in both IIH patients and non-IIH subjects as well as at the transverse sinus narrowing in non-IIH subjects. There was a discordant relationship between bony groove height and venous sinus height at the site of transverse sinus stenoses in IIH patients. In 5/23 IIH transverse sinus stenoses, the bony groove height was proportionate to that seen in non-IIH subjects. There were a further 8/23 cases where the small or absent sinus was associated with an absent bony groove. Transverse sinus tapered narrowings in subjects without IIH and in the majority of patients with IIH were associated with proportionately small or absent grooves, and these are postulated to be primary or fixed. Some patients with IIH demonstrate tapered transverse sinus stenoses with disproportionately large bony grooves, suggesting a secondary or acquired narrowing. This implies a varied aetiology for the transverse sinus stenoses of IIH. (orig.)

  17. Avifauna of Boni-Dodori National Reserves, Lamu and Garissa ...

    African Journals Online (AJOL)

    observers conducted a 60 min walk along a designated path in open ... rophoneus viridis were recorded in the Boni-Dodori area for the first time. ..... Mouse-coloured Sunbird Cyanomitra veroxii * .... Expedition Field techniques: Bird Surveys.

  18. First record of eocene bony fishes and crocodyliforms from Canada's Western Arctic.

    Science.gov (United States)

    Eberle, Jaelyn J; Gottfried, Michael D; Hutchison, J Howard; Brochu, Christopher A

    2014-01-01

    Discovery of Eocene non-marine vertebrates, including crocodylians, turtles, bony fishes, and mammals in Canada's High Arctic was a critical paleontological contribution of the last century because it indicated that this region of the Arctic had been mild, temperate, and ice-free during the early - middle Eocene (∼53-50 Ma), despite being well above the Arctic Circle. To date, these discoveries have been restricted to Canada's easternmost Arctic - Ellesmere and Axel Heiberg Islands (Nunavut). Although temporally correlative strata crop out over 1,000 km west, on Canada's westernmost Arctic Island - Banks Island, Northwest Territories - they have been interpreted as predominantly marine. We document the first Eocene bony fish and crocodyliform fossils from Banks Island. We describe fossils of bony fishes, including lepisosteid (Atractosteus), esocid (pike), and amiid, and a crocodyliform, from lower - middle Eocene strata of the Cyclic Member, Eureka Sound Formation within Aulavik National Park (∼76°N. paleolat.). Palynology suggests the sediments are late early to middle Eocene in age, and likely spanned the Early Eocene Climatic Optimum (EECO). These fossils extend the geographic range of Eocene Arctic lepisosteids, esocids, amiids, and crocodyliforms west by approximately 40° of longitude or ∼1100 km. The low diversity bony fish fauna, at least at the family level, is essentially identical on Ellesmere and Banks Islands, suggesting a pan-High Arctic bony fish fauna of relatively basal groups around the margin of the Eocene Arctic Ocean. From a paleoclimatic perspective, presence of a crocodyliform, gar and amiid fishes on northern Banks provides further evidence that mild, year-round temperatures extended across the Canadian Arctic during early - middle Eocene time. Additionally, the Banks Island crocodyliform is consistent with the phylogenetic hypothesis of a Paleogene divergence time between the two extant alligatorid lineages Alligator

  19. DIAGNOSTIC CRITERIA FOR PROLIFERATIVE THYROID LESIONS IN BONY FISHES

    Science.gov (United States)

    Thyroid proliferative lesions are rather common in bony fishes but disagreement exists in the fish pathology community concerning diagnostic criteria for hyperplastic versus neoplastic lesions. To simplify the diagnosis of proliferative thyroid lesions and to reduce confusion reg...

  20. Patterns of congenital bony spinal deformity and associated neural anomalies on X-ray and magnetic resonance imaging

    OpenAIRE

    Trenga, Anthony P.; Singla, Anuj; Feger, Mark A.; Abel, Mark F.

    2016-01-01

    Purpose Congenital malformations of the bony vertebral column are often accompanied by spinal cord anomalies; these observations have been reinforced with the use of magnetic resonance imaging (MRI). We hypothesized that the incidence of cord anomalies will increase as the number and complexity of bony vertebral abnormalities increases. Methods All patients aged ?13 years (n?=?75) presenting to the pediatric spine clinic from 2003?2013 with congenital bony spinal deformity and both radiograph...

  1. A clinico-radiologic study of bony remodeling of the fractured condyles in children

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jeong Shin; Park, Chang Seo [Department of Dentistry, The Graduate School, Yonsei University, Seoul (Korea, Republic of)

    1995-08-15

    Bony remodeling pattern of condyle fractures in children are different from in adult for growing of condyle, also might affect treatment and prognosis of the condyle fracture. Subjects of this clinical and radiologic study were 26 temporomandibular joints diagnosed as condyle fracture in 23 patients under 15 years old age, They were treated with conservative method at Dental Hospital of Yonsei University from Jan., 1986 to Oct., 1994. Bony remodeling related with fracture pattern was evaluated. The results obtained are as follows: 1. The ratio of male to female in patients with condyle fracture was 1 : 0.9 and the difference of sex ratio was not noted. Comparing with preschool-age group and school-age group, age frequency was higher in preschool-age group (83%). 2. Fallen down (54%) was the most frequent cause of condyle fractures. Traffic accident and slip down were followed. 3. The most common clinical sign of condyle fractures was tenderness to palpation (19 cases). Mouth opening limitation (17 cases), swelling (7 cases), malocclusion (3 cases) were next in order. 4. According to sites of condyle fractures, unilateral fractures were in 20 patients and bilateral fractures in 3 patients, therefore total 23 patients-26 cases of condyle fracture were observed. According to fracture distribution, condyle fractures were in 10 patients (44%). Condyle fractures with symphysis fracture (9 patients, 39%), condyle fractures with ascending ramus fracture (2 patients, 9%), condyle fracture with mandibular body fracture (1 patient, 4%), and condyle fractures with mandibular angle fracture (1 patient, 4%) were followed. 5. In displacement pattern of fractured fragment of mandibular condyle, displacement (17 cases, 66%) was most common. Dislocation (5 cases, 19%) and deviation (4 cases, 15%) were next in order. 6. During the observation period of fractured condyles, remodeling patterns of fracture sites related with articular fossa were observed with usual congealer shape in 23

  2. A clinico-radiologic study of bony remodeling of the fractured condyles in children

    International Nuclear Information System (INIS)

    Cho, Jeong Shin; Park, Chang Seo

    1995-01-01

    Bony remodeling pattern of condyle fractures in children are different from in adult for growing of condyle, also might affect treatment and prognosis of the condyle fracture. Subjects of this clinical and radiologic study were 26 temporomandibular joints diagnosed as condyle fracture in 23 patients under 15 years old age, They were treated with conservative method at Dental Hospital of Yonsei University from Jan., 1986 to Oct., 1994. Bony remodeling related with fracture pattern was evaluated. The results obtained are as follows: 1. The ratio of male to female in patients with condyle fracture was 1 : 0.9 and the difference of sex ratio was not noted. Comparing with preschool-age group and school-age group, age frequency was higher in preschool-age group (83%). 2. Fallen down (54%) was the most frequent cause of condyle fractures. Traffic accident and slip down were followed. 3. The most common clinical sign of condyle fractures was tenderness to palpation (19 cases). Mouth opening limitation (17 cases), swelling (7 cases), malocclusion (3 cases) were next in order. 4. According to sites of condyle fractures, unilateral fractures were in 20 patients and bilateral fractures in 3 patients, therefore total 23 patients-26 cases of condyle fracture were observed. According to fracture distribution, condyle fractures were in 10 patients (44%). Condyle fractures with symphysis fracture (9 patients, 39%), condyle fractures with ascending ramus fracture (2 patients, 9%), condyle fracture with mandibular body fracture (1 patient, 4%), and condyle fractures with mandibular angle fracture (1 patient, 4%) were followed. 5. In displacement pattern of fractured fragment of mandibular condyle, displacement (17 cases, 66%) was most common. Dislocation (5 cases, 19%) and deviation (4 cases, 15%) were next in order. 6. During the observation period of fractured condyles, remodeling patterns of fracture sites related with articular fossa were observed with usual congealer shape in 23

  3. Palaeobiology of Hyaenodon exiguus (Hyaenodonta, Mammalia) based on morphometric analysis of the bony labyrinth.

    Science.gov (United States)

    Pfaff, Cathrin; Nagel, Doris; Gunnell, Gregg; Weber, Gerhard W; Kriwet, Jürgen; Morlo, Michael; Bastl, Katharina

    2017-02-01

    Species of the extinct genus Hyaenodon were among the largest carnivorous mammals from the Late Eocene through Early Miocene in North America, Europe and Asia. The origin, phylogeny and palaeobiology of Hyaenodonta are still ambiguous. Most previous studies focused on teeth and dental function in these highly adapted species, which might be influenced by convergent morphologies. The anatomy of the bony labyrinth in vertebrates is generally quite conservative and, additionally, was used in functional-morphological studies. This study provides the first anatomical description of the bony labyrinth of the extinct European species Hyaenodon exiguus in comparison to selected extant carnivoran taxa discussed from a functional-morphological perspective. Hyaenodon exiguus may have occupied a hyaena-like dietary niche with a semi-arboreal lifestyle, based on the relative height, width and length of the semicircular canals of the inner ear. However, this contradicts previous functional-morphological studies focusing on the diameter of the canals, which presumably represent the signal of locomotion mode. © 2016 Anatomical Society.

  4. Manufacturing study of beryllium bonded structures

    International Nuclear Information System (INIS)

    Onozuka, M.; Hirai, S.; Kikuchi, K.; Oda, Y.; Shimizu, K.

    2004-01-01

    Manufacturing study has been conducted on Be-bonded structures employed in the first-wall panel of the blanket system for the ITER. For Be tiles bonded to the Cu-Cr-Zr alloy heat sink with stainless-steel cooling pipes, a one-axis hot press with two heating process has been used to bond the three materials. First, Cu-alloy and SS materials are bonded diffusively. Then, Be tiles are bonded to the pre-bonded structure under 20 MPa and at 560 degree C. An Al-Si base interlayer has been used to bond Be to the Cu-Alloy. Because of the limited heat processes using a conventional hot press, the manufacturing cost can be minimized. Using the above bonding techniques, a partial mockup of a blanket first-wall panel with 16 Be tiles (with 50 mm in size) has been successfully manufactured. (author)

  5. Bilateral bony fusion around the supraspinatus muscle inducing muscle hypoplasia and shoulder pain

    Energy Technology Data Exchange (ETDEWEB)

    Son, YeNa; Jin, Wook; Park, So Young [Kyung Hee University Hospital at Gangdong, Department of Radiology, 892, Dongnam-ro, Gangdong-gu, Seoul (Korea, Republic of); Ryu, Kyung Nam; Park, Ji Seon [Kyung Hee University Hospital, Department of Radiology, 23 Kyunghee-daero, Dongdaemun-gu, Seoul (Korea, Republic of)

    2017-03-15

    We describe the case of a 30-year-old man who developed chronic bilateral shoulder pain that relapsed and remitted over the course of 1 year. The patient was diagnosed with congenital shoulder fusion anomalies. The right shoulder showed anomalous accessory articulation between the distal third of the clavicle and the acromion along with normal articulation of the shoulder on CT. At the left shoulder, bony fusions were present between the distal portion of the clavicle, the acromion, and the coracoid process, and between the coracoid process, upper portion of the glenoid, and upper body of the scapula, which formed a bony canal and was responsible for hypoplasia of the supraspinatus muscle on CT and MRI. To our knowledge, this is the first description of such congenital shoulder anomalies with extreme bony fusion and is an illustrative example of how imaging may be used to differentiate fusion from other congenital abnormalities of the shoulder to aid diagnosis. (orig.)

  6. Bony ankylosis of temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byeong Do; Yoon, Young Nam; Um, Ki Doo; Ra, Jong Ill; Lee, Wan [School of Dentistry, Wonkwang University, Iksan (Korea, Republic of)

    2002-06-15

    Ankylosis of joint is defined as limited movement due to infection, trauma, or surgical procedure. A 59-year-old female with a chief complaint of limited movements during mouth opening had a positive history of trauma to her right TMJ area about 5 years ago. From that time, progressive mouth opening limitation and intermittent pain have occurred. At the time of admission the patient showed mandibular deviation to the right side during mouth opening, with a maximum opening limited to 5 mm. On plain radiographs, right condylar enlargement and joint space reduction by newly formed bony tissues were observed. CT scans showed right condylar enlargement, cortical sclerosis, and thickening of the condyle, articular fossa and articular eminence.

  7. A tomographic study of positional and bony changes in the temporomandibular joint following orthognathic surgery

    International Nuclear Information System (INIS)

    Song, Nam Kyu; Kim Min Suk; Koh, Kwang Joon

    1992-01-01

    The purpose of this study was to aid in the evaluation of prognosis of temporomandibular joint following orthognathic surgery. For this study, 20 patients (40 TMJ) who undergone orthognathic surgery were examined. Preoperative and postoperative tomograms of TMJ were taken. And the subjects were divided into 3 groups according to postoperative periods. The obtained results were as follows : 1. There were no significant differences between preoperative and postoperative changes in joint spaces in each group and between groups (P<0.05). 2. There were no significant differences between preoperative and postoperative ratio of joint spaces (P<0.05).3. There were no significant differences between preoperative and postoperative changes in the range of motion of condylar head (P<0.05). 4. The bony changes of condylar head were observed in 14 (35%) condyles (6 erosion, 2 flattening, 5 double contour, 1 osteophyte).

  8. A tomographic study of positional and bony changes in the temporomandibular joint following orthognathic surgery

    Energy Technology Data Exchange (ETDEWEB)

    Song, Nam Kyu; Kim Min Suk; Koh, Kwang Joon [Dept. of Oral Radiology, College of Dentistry, Chonpook National University, Chonju (Korea, Republic of)

    1992-08-15

    The purpose of this study was to aid in the evaluation of prognosis of temporomandibular joint following orthognathic surgery. For this study, 20 patients (40 TMJ) who undergone orthognathic surgery were examined. Preoperative and postoperative tomograms of TMJ were taken. And the subjects were divided into 3 groups according to postoperative periods. The obtained results were as follows : 1. There were no significant differences between preoperative and postoperative changes in joint spaces in each group and between groups (P<0.05). 2. There were no significant differences between preoperative and postoperative ratio of joint spaces (P<0.05).3. There were no significant differences between preoperative and postoperative changes in the range of motion of condylar head (P<0.05). 4. The bony changes of condylar head were observed in 14 (35%) condyles (6 erosion, 2 flattening, 5 double contour, 1 osteophyte).

  9. CAT & MAUS: A novel system for true dynamic motion measurement of underlying bony structures with compensation for soft tissue movement.

    Science.gov (United States)

    Jia, Rui; Monk, Paul; Murray, David; Noble, J Alison; Mellon, Stephen

    2017-09-06

    Optoelectronic motion capture systems are widely employed to measure the movement of human joints. However, there can be a significant discrepancy between the data obtained by a motion capture system (MCS) and the actual movement of underlying bony structures, which is attributed to soft tissue artefact. In this paper, a computer-aided tracking and motion analysis with ultrasound (CAT & MAUS) system with an augmented globally optimal registration algorithm is presented to dynamically track the underlying bony structure during movement. The augmented registration part of CAT & MAUS was validated with a high system accuracy of 80%. The Euclidean distance between the marker-based bony landmark and the bony landmark tracked by CAT & MAUS was calculated to quantify the measurement error of an MCS caused by soft tissue artefact during movement. The average Euclidean distance between the target bony landmark measured by each of the CAT & MAUS system and the MCS alone varied from 8.32mm to 16.87mm in gait. This indicates the discrepancy between the MCS measured bony landmark and the actual underlying bony landmark. Moreover, Procrustes analysis was applied to demonstrate that CAT & MAUS reduces the deformation of the body segment shape modeled by markers during motion. The augmented CAT & MAUS system shows its potential to dynamically detect and locate actual underlying bony landmarks, which reduces the MCS measurement error caused by soft tissue artefact during movement. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Repair of pars defects by segmental transverse wiring for athletes with symptomatic spondylolysis: relationship between bony union and postoperative symptoms.

    Science.gov (United States)

    Hioki, Akira; Miyamoto, Kei; Sadamasu, Aya; Nozawa, Satoshi; Ogawa, Hiroyasu; Fushimi, Kazunari; Hosoe, Hideo; Shimizu, Katsuji

    2012-04-20

    Retrospective study of surgery for spondylolysis patients. To assess clinical outcome of bony union using multislice computed tomography after segmental wiring fixation. How bony union affects surgical outcome of spondylolysis repair is unclear. Forty-four athletes with symptomatic spondylolysis (33 men and 11 women; mean age, 24.2 ± 5.4 years) who underwent segmental wiring fixation were evaluated retrospectively at a mean follow-up of 85 ± 17 months. The level of spondylolysis was L5 in 42 cases, and both L4 and L5 in 2 cases, giving a total of 46 operative levels of vertebrae. Bony union using axial and sagittal reconstruction images of computed tomography, the Japanese Orthopaedic Association (JOA) score for back pain, and complications were reviewed. State of bony union was classified as bilateral union, unilateral union, or nonunion. The total score and the improvement ratio of the JOA score were compared among the 3 groups. Bilateral bony union was obtained in 29 cases (31 of 46 vertebrae, 67.4%). Six cases (13%) showed unilateral union, and 9 cases (19.6%) showed nonunion. JOA score increased significantly after surgery in all groups, average improvement rate was 78.9% in the bilateral group, 63.6% in the unilateral group, and 29.8% in the nonunion group; differences among the 3 groups were significant (P spondylolysis repair.

  11. Comparative Anatomy of the Bony Labyrinth (Inner Ear) of Placental Mammals

    Science.gov (United States)

    Ekdale, Eric G.

    2013-01-01

    Background Variation is a naturally occurring phenomenon that is observable at all levels of morphology, from anatomical variations of DNA molecules to gross variations between whole organisms. The structure of the otic region is no exception. The present paper documents the broad morphological diversity exhibited by the inner ear region of placental mammals using digital endocasts constructed from high-resolution X-ray computed tomography (CT). Descriptions cover the major placental clades, and linear, angular, and volumetric dimensions are reported. Principal Findings The size of the labyrinth is correlated to the overall body mass of individuals, such that large bodied mammals have absolutely larger labyrinths. The ratio between the average arc radius of curvature of the three semicircular canals and body mass of aquatic species is substantially lower than the ratios of related terrestrial taxa, and the volume percentage of the vestibular apparatus of aquatic mammals tends to be less than that calculated for terrestrial species. Aspects of the bony labyrinth are phylogenetically informative, including vestibular reduction in Cetacea, a tall cochlear spiral in caviomorph rodents, a low position of the plane of the lateral semicircular canal compared to the posterior canal in Cetacea and Carnivora, and a low cochlear aspect ratio in Primatomorpha. Significance The morphological descriptions that are presented add a broad baseline of anatomy of the inner ear across many placental mammal clades, for many of which the structure of the bony labyrinth is largely unknown. The data included here complement the growing body of literature on the physiological and phylogenetic significance of bony labyrinth structures in mammals, and they serve as a source of data for future studies on the evolution and function of the vertebrate ear. PMID:23805251

  12. Bony injuries in trauma patients diagnosed by radiological examination

    International Nuclear Information System (INIS)

    Amponsah, G.; Gorleku, P. N.

    2015-01-01

    This study was carried out to determine the incidence of bony injuries in trauma patients who had plain radiographs done at the Central Regional Hospital in Cape Coast. This is a retrospective study based on plain radiographs taken by trauma patients who reported to the Central Regional Hospital. The case notes of all patients with a discharge diagnosis of Road Traffic Accident or trauma of all aetiologies that presented to the hospital between January 2005 and December 2011 were retrieved, and those patients that had skeletal radiographic examinations were included in this study. The total number of cases seen was 1,133. The ages of the patients ranged between 1 and 72 years. Sixty-nine (6.1%) of the patients were between 1 and 4 years old, with the majority between 20 and 49 years old, constituting 52.3%, with patients 60 years and above at 9.2%. There was statistically significant difference between male and female patients (p=0.001). A total of 912 (80.5%) patients had radiographic examination done out of which only 324 (35.5%) radiographs could be retrieved. There were 106 (32.7%) radiographs with various bony injuries which was statistically significant (p=0.001). Rib fractures represented 19/106 (17.9%) of which 62.5% had multiple rib fractures. Fifty-eight (54.7%) had long bone fractures. Other anatomical sites included the pelvis and the skull. Conclusion: Trauma is a major public health problem in the country, involving mainly the productive age group. Unnecessary exposure to X-rays is common. Inadequate management of trauma patients negatively impacts on the outcome of trauma patients. Trauma prevention is the best way forward.(au)

  13. First Record of Eocene Bony Fishes and Crocodyliforms from Canada’s Western Arctic

    Science.gov (United States)

    Eberle, Jaelyn J.; Gottfried, Michael D.; Hutchison, J. Howard; Brochu, Christopher A.

    2014-01-01

    Background Discovery of Eocene non-marine vertebrates, including crocodylians, turtles, bony fishes, and mammals in Canada’s High Arctic was a critical paleontological contribution of the last century because it indicated that this region of the Arctic had been mild, temperate, and ice-free during the early – middle Eocene (∼53–50 Ma), despite being well above the Arctic Circle. To date, these discoveries have been restricted to Canada’s easternmost Arctic – Ellesmere and Axel Heiberg Islands (Nunavut). Although temporally correlative strata crop out over 1,000 km west, on Canada’s westernmost Arctic Island – Banks Island, Northwest Territories – they have been interpreted as predominantly marine. We document the first Eocene bony fish and crocodyliform fossils from Banks Island. Principal Findings We describe fossils of bony fishes, including lepisosteid (Atractosteus), esocid (pike), and amiid, and a crocodyliform, from lower – middle Eocene strata of the Cyclic Member, Eureka Sound Formation within Aulavik National Park (∼76°N. paleolat.). Palynology suggests the sediments are late early to middle Eocene in age, and likely spanned the Early Eocene Climatic Optimum (EECO). Conclusions/Significance These fossils extend the geographic range of Eocene Arctic lepisosteids, esocids, amiids, and crocodyliforms west by approximately 40° of longitude or ∼1100 km. The low diversity bony fish fauna, at least at the family level, is essentially identical on Ellesmere and Banks Islands, suggesting a pan-High Arctic bony fish fauna of relatively basal groups around the margin of the Eocene Arctic Ocean. From a paleoclimatic perspective, presence of a crocodyliform, gar and amiid fishes on northern Banks provides further evidence that mild, year-round temperatures extended across the Canadian Arctic during early – middle Eocene time. Additionally, the Banks Island crocodyliform is consistent with the phylogenetic hypothesis of a Paleogene divergence

  14. Patterns of congenital bony spinal deformity and associated neural anomalies on X-ray and magnetic resonance imaging.

    Science.gov (United States)

    Trenga, Anthony P; Singla, Anuj; Feger, Mark A; Abel, Mark F

    2016-08-01

    Congenital malformations of the bony vertebral column are often accompanied by spinal cord anomalies; these observations have been reinforced with the use of magnetic resonance imaging (MRI). We hypothesized that the incidence of cord anomalies will increase as the number and complexity of bony vertebral abnormalities increases. All patients aged ≤13 years (n = 75) presenting to the pediatric spine clinic from 2003-2013 with congenital bony spinal deformity and both radiographs and MRI were analyzed retrospectively for bone and neural pathology. Chi-squared analysis was used to compare groups for categorical dependent variables. Independent t tests were used for continuous dependent variables. Significance was set at p formation had a higher incidence of cord anomalies (73 %) than failures of formation (50 %) or segmentation (45 %) alone (p = 0.065). Deformities in the sacrococcygeal area had the highest rate of spinal cord anomalies (13 of 15 patients, 87 %). In 35 cases (47 %), MRI revealed additional bony anomalies that were not seen on the radiographs. As the number of bony malformations increased, we found a higher incidence of cord anomalies. Clinicians should have increased suspicion of spinal cord pathology in the presence of mixed failures of segmentation and formation.

  15. Management of segmental bony defects: the role of osteoconductive orthobiologics.

    Science.gov (United States)

    McKee, Michael D

    2006-01-01

    Our knowledge about, and the availability of, orthobiologic materials has increased exponentially in the last decade. Although previously confined to the experimental or animal-model realm, several orthobiologics have been shown to be useful in a variety of clinical situations. As surgical techniques in vascular anastomosis, soft-tissue coverage, limb salvage, and fracture stabilization have improved, the size and frequency of bony defects (commensurate with the severity of the initial injury) have increased, as well. Because all methods of managing segmental bony defects have drawbacks, a need remains for a readily available, void-filling, inexpensive bone substitute. Such a bone substitute fulfills a permissive role in allowing new bone to grow into a given defect. Such potential osteoconductive materials include ceramics, calcium sulfate or calcium phosphate compounds, hydroxyapatite, deproteinized bone, corals, and recently developed polymers. Some materials that have osteoinductive properties, such as demineralized bone matrix, also display prominent osteoconductive properties.

  16. Imaging of the hip and bony pelvis. Techniques and applications

    Energy Technology Data Exchange (ETDEWEB)

    Davies, A.M. [Royal Orthopaedic Hospital, Birmingham (United Kingdom). MRI Centre; Johnson, K.J. [Princess of Wales Birmingham Children' s Hospital (United Kingdom); Whitehouse, R.W. (eds.) [Manchester Royal Infirmary (United Kingdom). Dept. of Clinical Radiology

    2006-07-01

    This is a comprehensive textbook on imaging of the bony pelvis and hip joint that provides a detailed description of the techniques and imaging findings relevant to this complex anatomical region. In the first part of the book, the various techniques and procedures employed for imaging the pelvis and hip are discussed in detail. The second part of the book documents the application of these techniques to the diverse clinical problems and diseases encountered. Among the many topics addressed are congenital and developmental disorders including developmental dysplasia of the hip, irritable hip and septic arthritis, Perthes' disease and avascular necrosis, slipped upper femoral epiphysis, bony and soft tissue trauma, arthritis, tumours and hip prostheses. Each chapter is written by an acknowledged expert in the field, and a wealth of illustrative material is included. This book will be of great value to musculoskeletal and general radiologists, orthopaedic surgeons and rheumatologists. (orig.)

  17. Arthroscopic treatment of bony loose bodies in the subacromial space

    Directory of Open Access Journals (Sweden)

    Wei Li

    2015-01-01

    Conclusion: The mechanism of formation of bony loose bodies is not clear, may be associated with synovial cartilage metaplasia. Arthroscopic removal of loose bodies and bursa debridement is a good option for treatment of the loose body in the subacromial space, which can receive good function.

  18. Association between condylar morphology and changes in bony microstructure and subsynovial inflammation in experimental temporomandibular joint arthritis

    DEFF Research Database (Denmark)

    Kristensen, Kasper Dahl; Hauge, Ellen Margrethe; Dalstra, Michel

    2010-01-01

    Association between condylar morphology and changes in bony microstructure and subsynovial inflammation in experimental temporomandibular joint arthritis. 86. Congress of the European Orthodontic Society, Slovenien, 2010.......Association between condylar morphology and changes in bony microstructure and subsynovial inflammation in experimental temporomandibular joint arthritis. 86. Congress of the European Orthodontic Society, Slovenien, 2010....

  19. The spectrum of allergy to South African bony fish (Teleosti ...

    African Journals Online (AJOL)

    Volunteer population-based cohort in the Western Cape. Participants. 105 volunteer subjects with suspected fish allergy were recruited by advertising in the local press. Main outcome. Species-specific bony fish allergy was confirmed or refuted by DBPCFC. Results. The four most common seafood species reported to cause ...

  20. Comparison of carina-based versus bony anatomy-based registration for setup verification in esophageal cancer radiotherapy.

    Science.gov (United States)

    Machiels, Mélanie; Jin, Peng; van Gurp, Christianne H; van Hooft, Jeanin E; Alderliesten, Tanja; Hulshof, Maarten C C M

    2018-03-21

    To investigate the feasibility and geometric accuracy of carina-based registration for CBCT-guided setup verification in esophageal cancer IGRT, compared with current practice bony anatomy-based registration. Included were 24 esophageal cancer patients with 65 implanted fiducial markers, visible on planning CTs and follow-up CBCTs. All available CBCT scans (n = 236) were rigidly registered to the planning CT with respect to the bony anatomy and the carina. Target coverage was visually inspected and marker position variation was quantified relative to both registration approaches; the variation of systematic (Σ) and random errors (σ) was estimated. Automatic carina-based registration was feasible in 94.9% of the CBCT scans, with an adequate target coverage in 91.1% compared to 100% after bony anatomy-based registration. Overall, Σ (σ) in the LR/CC/AP direction was 2.9(2.4)/4.1(2.4)/2.2(1.8) mm using the bony anatomy registration compared to 3.3(3.0)/3.6(2.6)/3.9(3.1) mm for the carina. Mid-thoracic placed markers showed a non-significant but smaller Σ in CC and AP direction when using the carina-based registration. Compared with a bony anatomy-based registration, carina-based registration for esophageal cancer IGRT results in inadequate target coverage in 8.9% of cases. Furthermore, large Σ and σ, requiring larger anisotropic margins, were seen after carina-based registration. Only for tumors entirely confined to the mid-thoracic region the carina-based registration might be slightly favorable.

  1. Prostate position relative to pelvic bony anatomy based on intraprostatic gold markers and electronic portal imaging

    International Nuclear Information System (INIS)

    Schallenkamp, John M.; Herman, Michael G.; Kruse, Jon J.; Pisansky, Thomas M.

    2005-01-01

    Purpose: To describe the relative positions and motions of the prostate, pelvic bony anatomy, and intraprostatic gold fiducial markers during daily electronic portal localization of the prostate. Methods and Materials: Twenty prostate cancer patients were treated supine with definitive external radiotherapy according to an on-line target localization protocol using three or four intraprostatic gold fiducial markers and an electronic portal imaging device. Daily pretherapy and through-treatment electronic portal images (EPIs) were obtained for each of four treatment fields. The patients' pelvic bony anatomy, intraprostatic gold markers, and a best visual match to the target (i.e., prostate) were identified on simulation digitally reconstructed radiographs and during daily treatment setup and delivery. These data provided quantitative inter- and intrafractional analysis of prostate motion, its position relative to the bony anatomy, and the individual intraprostatic fiducial markers. Treatment planning margins, with and without on-line localization, were subsequently compared. Results: A total of 22,266 data points were obtained from daily pretherapy and through-treatment EPIs. The pretherapy three-dimensional (3D) average displacement of the fiducial markers, as a surrogate for the prostate, was 5.6 mm, which improved to 2.8 mm after use of the localization protocol. The bony anatomy 3D average displacement was 4.4 mm both before and after localization to the prostate (p = 0.46). Along the superior-inferior (SI), anterior-posterior (AP), and right-left (RL) axes, the average prostate displacement improved from 2.5, 3.7, and 1.9 mm, respectively, before localization to 1.4, 1.6, and 1.1 mm after (all p < 0.001). The pretherapy to through-treatment position of the bony landmarks worsened from 1.7 to 2.5 mm (p < 0.001) in the SI axis, remained statistically unchanged at 2.8 mm (p = 0.39) in the AP axis, and improved from 2.0 to 1.2 mm in the RL axis (p < 0.001). There

  2. SU-E-J-33: Comparison Between Soft Tissue Alignment and Bony Alignment for Pancreatic Cancer Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Y; Crane, C; Krishnan, S; Das, P; Koay, E; Beddar, S [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose An IGRT modality for pancreatic cancer treatment with dose escalation at our institution is in-room daily CT imaging. The purpose of this study is to assess the difference between soft tissue alignment and bony alignment for pancreatic tumor localization. Methods Eighteen patients with pancreatic tumors who underwent IMRT treatment with an inspiration breath-hold technique between July 2012 and February 2015 are included in this study. Prior to each treatment, a CT scan was acquired. The CT image guidance started with auto-alignment to either the bony anatomy (vertebral bodies) or fiducials (for the six patients with the stent in/near the tumor) and then, when necessary, manual adjustments were made based on soft tissue alignment using clinical software (CT-Assisted Targeting system). The difference between soft tissue alignment and bony/fiducial alignment was evaluated. Results Of all 380 treatments, manual adjustment was made in 225 treatments, ranging from 11% (3 treatments out of 28) to 96% (27 treatments out of 28) per patient. The mean of the difference between soft tissue alignment and bony/fiducial alignment per patient ranged from −3.6 to 0.3 mm, −1.5 to 2.8 mm, and −3.3 to 3.4 mm in the AP, SI, and RL directions, respectively. The maximum difference over all treatments was −9.5, −14.6, and −14.6 mm in the AP, SI, and RL directions, respectively. Conclusion About 60% of the time, manual adjustment based on soft tissue alignment was required. The extent of manual adjustment was usually small but varied significantly from patient to patient. The ultimate goal of the IGRT modality using daily CT imaging is not to fully cover the target but to spare organs-at-risk as much as possible to avoid them moving into higher dose gradients than accepted in the treatment plan. To this end, manual adjustment based on soft tissue alignment is critically important.

  3. Bony exostosis of the atlas with resultant cranial nerve palsy

    International Nuclear Information System (INIS)

    Slavotinek, J.P.; Sage, M.R.; Brophy, B.P.

    1991-01-01

    A case of tenth and twelfth nerve compression secondary to a bony exostosis of the first cervical vertebra is described. This uncommon phenomenon serves to outline the importance of imaging the course of a cranial nerve when no intracranial abnormality is demonstrable on CT or MRI. The radiologic features of spinal osteochondromas are reviewed. (orig.)

  4. SU-E-J-94: Positioning Errors Resulting From Using Bony Anatomy Alignment for Treating SBRT Lung Tumor

    International Nuclear Information System (INIS)

    Frame, C; Ding, G

    2014-01-01

    Purpose: To quantify patient setups errors based on bony anatomy registration rather than 3D tumor alignment for SBRT lung treatments. Method: A retrospective study was performed for patients treated with lung SBRT and imaged with kV cone beam computed tomography (kV-CBCT) image-guidance. Daily CBCT images were registered to treatment planning CTs based on bony anatomy alignment and then inter-fraction tumor movement was evaluated by comparing shift in the tumor center in the medial-lateral, anterior-posterior, and superior-inferior directions. The PTV V100% was evaluated for each patient based on the average daily tumor displacement to assess the impact of the positioning error on the target coverage when the registrations were based on bony anatomy. Of the 35 patients studied, 15 were free-breathing treatments, 10 used abdominal compression with a stereotactic body frame, and the remaining 10 were performed with BodyFIX vacuum bags. Results: For free-breathing treatments, the range of tumor displacement error is between 1–6 mm in the medial-lateral, 1–13 mm in the anterior-posterior, and 1–7 mm in the superior-inferior directions. These positioning errors lead to 6–22% underdose coverage for PTV - V100% . Patients treated with abdominal compression immobilization showed positional errors of 0–4mm mediallaterally, 0–3mm anterior-posteriorly, and 0–2 mm inferior-superiorly with PTV - V100% underdose ranging between 6–17%. For patients immobilized with the vacuum bags, the positional errors were found to be 0–1 mm medial-laterally, 0–1mm anterior-posteriorly, and 0–2 mm inferior-superiorly with PTV - V100% under dose ranging between 5–6% only. Conclusion: It is necessary to align the tumor target by using 3D image guidance to ensure adequate tumor coverage before performing SBRT lung treatments. The BodyFIX vacuum bag immobilization method has the least positioning errors among the three methods studied when bony anatomy is used for

  5. 1 mil gold bond wire study.

    Energy Technology Data Exchange (ETDEWEB)

    Huff, Johnathon; McLean, Michael B.; Jenkins, Mark W.; Rutherford, Brian Milne

    2013-05-01

    In microcircuit fabrication, the diameter and length of a bond wire have been shown to both affect the current versus fusing time ratio of a bond wire as well as the gap length of the fused wire. This study investigated the impact of current level on the time-to-open and gap length of 1 mil by 60 mil gold bond wires. During the experiments, constant current was provided for a control set of bond wires for 250ms, 410ms and until the wire fused; non-destructively pull-tested wires for 250ms; and notched wires. The key findings were that as the current increases, the gap length increases and 73% of the bond wires will fuse at 1.8A, and 100% of the wires fuse at 1.9A within 60ms. Due to the limited scope of experiments and limited data analyzed, further investigation is encouraged to confirm these observations.

  6. Post Pelvic Radiotherapy Bony Changes

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Seung Jae [Samsung Medical Center, Seoul (Korea, Republic of)

    2009-03-15

    There has been recent interest in radiation-induced bone injury in clinical conditions, especially for pelvic insufficiency fracture (PIF). A PIF is caused by the effect of normal or physiological stress on bone with demineralization and decreased elastic resistance. Pelvic radiotherapy (RT) can also contribute to the development of a PIF. A PIF has been regarded as a rare complication with the use of megavoltage equipment. However, recent studies have reported the incidence of PIFs as 8.2{approx}20% after pelvic RT in gynecological patients, an incidence that was higher than previously believed. The importance of understanding a PIF lies in the potential for misdiagnosis as a bony metastasis. If patients complain of pelvic pain after whole-pelvis radiation therapy, the presence of a PIF must be considered in the differential diagnosis. The use of multibeam arrangements and conformal RT to reduce the volume and dose of irradiated pelvic bone can be helpful to minimize the risk of fracture. In addition to a PIF, osteonecrosis and avascular necrosis of the femoral head can develop after radiation therapy. Osteoradionecrosis of the pelvic bone is a clinical diagnostic challenge that must be differentiated from an osseous metastasis. A post-radiation bone sarcoma can result as a long-term sequela of pelvic irradiation for uterine cervical cancer.

  7. Severe bony ankylosis of the temporomandibular joint on one side and contralateral adhesion: A case report

    International Nuclear Information System (INIS)

    Song, Ji Young; Kim, Seong Gon; Choi, Hang Moon; Kim, Hyun Jung

    2015-01-01

    Bony fusion between the mandibular condyle and skull base involves temporomandibular joint (TMJ) bony ankylosis. This condition might originate from trauma, infection, or systemic disease. TMJ adhesion can develop after synovial damage. Both TMJ ankylosis and adhesion lead to functional impairment and pain. Here, we present a case of a 50-year-old female who had bony ankylosis of the right TMJ and adhesion of the left TMJ. She had otitis media in the right ear. A large mass in the right TMJ was observed on computed tomograph. Magnetic resonance image showed a large fused bone mass with normal bone marrow in the right TMJ and flattening of the condyle with a thin disk in the left TMJ. Gap arthroplasty with temporal fascia was performed on the right TMJ, and discectomy, high condylectomy, and coronoidectomy were performed on the left TMJ. During a 2-year follow-up after surgery, the patient had no recurrence

  8. Severe bony ankylosis of the temporomandibular joint on one side and contralateral adhesion: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ji Young [Dept. of Oral and Maxillofacial Surgery, Jeju National University Hospital, Jeju National University School of Medicine, Jeju (Korea, Republic of); Kim, Seong Gon; Choi, Hang Moon [School of Dentistry, Gangneung-Wonju National University, Gangneung (Korea, Republic of); Kim, Hyun Jung [Dept. of Anesthesiology and Pain Medicine, Jeju National University School of Medicine, Jeju (Korea, Republic of)

    2015-06-15

    Bony fusion between the mandibular condyle and skull base involves temporomandibular joint (TMJ) bony ankylosis. This condition might originate from trauma, infection, or systemic disease. TMJ adhesion can develop after synovial damage. Both TMJ ankylosis and adhesion lead to functional impairment and pain. Here, we present a case of a 50-year-old female who had bony ankylosis of the right TMJ and adhesion of the left TMJ. She had otitis media in the right ear. A large mass in the right TMJ was observed on computed tomograph. Magnetic resonance image showed a large fused bone mass with normal bone marrow in the right TMJ and flattening of the condyle with a thin disk in the left TMJ. Gap arthroplasty with temporal fascia was performed on the right TMJ, and discectomy, high condylectomy, and coronoidectomy were performed on the left TMJ. During a 2-year follow-up after surgery, the patient had no recurrence.

  9. Does bony hip morphology affect the outcome of treatment for patients with adductor-related groin pain?

    DEFF Research Database (Denmark)

    Hölmich, Per; Thorborg, Kristian; Nyvold, Per

    2014-01-01

    BACKGROUND: Adductor-related groin pain and bony morphology such as femoroacetabular impingement (FAI) or hip dysplasia can coexist clinically. A previous randomised controlled trial in which athletes with adductor-related groin pain underwent either passive treatment (PT) or active treatment (AT......) showed good results in the AT group. The primary purpose of the present study was to evaluate if radiological signs of FAI or hip dysplasia seem to affect the clinical outcome, initially and at 8-12 years of follow-up. METHODS: 47 patients (80%) were available for follow-up. The clinical result......, there was no significant difference in the distribution of Tönnis grades between hips that had an unchanged or improved outcome compared with hips that had a worse outcome over time (p=0.145). CONCLUSIONS: No evidence was found that bony hip morphology related to FAI or dysplasia prevents successful outcome...

  10. Melorheostosis of the hand with complicating bony spur formation and bursal inflammation: diagnosis and treatment

    International Nuclear Information System (INIS)

    Ameen, S.; Anderson, S.E.; Nagy, L.; Gerich, U.

    2002-01-01

    A 37-year old woman presented with intolerable pain associated with a slowly growing mass on the dorsum of the right hand. The radiographs were characteristic of melorheostosis involving the third and fourth metacarpals, with a cortical bony projection extending from the base of the third metacarpal eroding slightly into the fourth metacarpal, associated with bursal formation. Magnetic resonance imaging (MRI) demonstrated an inflamed bursal collection adjacent to the spur. This region corresponded to the patient's severe clinical, focal pain. To our knowledge, this is the first case report in which melorheostosis of the hand has been associated with bony spur formation and complicated by an inflamed bursa. (orig.)

  11. Reliability of the Bony Anatomy in Image-Guided Stereotactic Radiotherapy of Brain Metastases

    International Nuclear Information System (INIS)

    Guckenberger, Matthias; Baier, Kurt; Guenther, Iris; Richter, Anne; Wilbert, Juergen; Sauer, Otto; Vordermark, Dirk; Flentje, Michael

    2007-01-01

    Purpose: To evaluate whether the position of brain metastases remains stable between planning and treatment in cranial stereotactic radiotherapy (SRT). Methods and Materials: Eighteen patients with 20 brain metastases were treated with single-fraction (17 lesions) or hypofractionated (3 lesions) image-guided SRT. Median time interval between planning and treatment was 8 days. Before treatment a cone-beam CT (CBCT) and a conventional CT after application of i.v. contrast were acquired. Setup errors using automatic bone registration (CBCT) and manual soft-tissue registration of the brain metastases (conventional CT) were compared. Results: Tumor size was not significantly different between planning and treatment. The three-dimensional setup error (mean ± SD) was 4.0 ± 2.1 mm and 3.5 ± 2.2 mm according to the bony anatomy and the lesion itself, respectively. A highly significant correlation between automatic bone match and soft-tissue registration was seen in all three directions (r ≥ 0.88). The three-dimensional distance between the isocenter according to bone match and soft-tissue registration was 1.7 ± 0.7 mm, maximum 2.8 mm. Treatment of intracranial pressure with steroids did not influence the position of the lesion relative to the bony anatomy. Conclusion: With a time interval of approximately 1 week between planning and treatment, the bony anatomy of the skull proved to be an excellent surrogate for the target position in image-guided SRT

  12. Morphometric Measurements of Bony Nasolacrimal Canal in Children.

    Science.gov (United States)

    Ela, Araz Server; Cigdem, Kalaycik Ertugay; Karagoz, Yesim; Yigit, Ozgur; Longur, Ecem Sevim

    2018-05-01

    Morphology and dimensions of the bony nasolacrimal canal duct (BNLD) as a key factor in the development of primary acquired nasolacrimal duct obstruction. We aimed to obtain detailed morphometric analysis of BNLD in children without nasolacrimal duct pathology by using computed tomography and provide standard measurements by means of age which could be utilized in planning management or in invasive interventions. Picture Archiving Communication Systems database of our hospital's radiology department was searched for this retrospective study. Subjects were under 18 years of age who had undergone a paranasal, maxillofacial, or temporal bone high-resolution computed tomography scan in last 2 years with various indications. Those with fractures including facial bones and/or nasolacrimal canal or history of nasolacrimal duct pathology were excluded from the study. We measured the diameter, angle, and surface area of BNLD. A total number of 136 subjects (86 boys, 50 girls) were included in the study. The average age was 7.3 ± 5.1 years. We documented statistically significantly positive correlation between all measured diameters and ages (P  0.050). Our study demonstrated that development of BNLD continues during childhood, regardless of gender.

  13. Giant Atretic Occipital Lipoencephalocele in an Adult with Bony Outgrowth.

    Science.gov (United States)

    Nimkar, Kshama; Sood, Dinesh; Soni, Pawan; Chauhan, Narvir; Surya, Mukesh

    2016-01-01

    We present unique case of a giant extracranial atretic occipital lipoencephalocele in an adult patient with new bone formation within it which was not associated with any developmental malformation of brain. Resection of the lipoencephalocele was performed for esthetic reasons. 18 year old female patient presented to the surgery OPD with complains of a large mass in the occipital region present since birth. It was of size of a betel nut at the time of birth and gradually increased in size over a long period of time. It was painless and not associated with any other constitutional symptoms. On examination the rounded fluctuant mass was present in the midline in occipital region covered with alopecic skin with dimpling in the overlying skin. On MRI there was mass showing both T1 and T2 hyperintense signal area suggestive of fat component. Herniation of meninges and atretic brain parenchyma was also seen through a defect in the occipital bone in the midline. There was a Y shaped bony outgrowth seen arising from occipital bone into the mass which was quite unusual in association with an atretic lipoencephalocele. A large lipoencephalocele with bony outgrowth in an adult patient is a rare presentation of atreic occipital encephalocele.

  14. Selected ophthalmic diagnostic tests, bony orbit anatomy, and ocular histology in sambar deer (Rusa unicolor).

    Science.gov (United States)

    Oriá, Arianne P; Gomes Junior, Deusdete C; Oliveira, Alberto Vinícius D; Curvelo, Victor P; Estrela-Lima, Alessandra; Pinna, Melissa H; Meneses, Íris D S; Filho, Emanoel F M; Ofri, Ron

    2015-01-01

    The purpose of this study was to establish reference values for diagnostic ophthalmic tests in sambar deer (Rusa unicolor) as well as to describe the most relevant features of the bony orbital anatomy and ocular histology. Twenty healthy animals, free living in a forest reserve, that were captured for clinical evaluation as part of a health survey were evaluated. Schirmer tear test-1 (STT1), conjunctival microbiota, intraocular pressure (IOP), conjunctival cytology, anatomy of the bony orbit, and ocular histology were studied. Mean ± SD STT1 and IOP values were 18.8 ± 4.7 mm and 11.4 ± 2.8 mmHg, respectively. IOP was significantly higher in adult (4-8 years) animals (P = 0.04). Bacterial growth was present in 100% of the samples, with a prevalence for Staphylococcus sp. and Bacillus sp. The conjunctival cytology revealed predominance of columnar epithelial cells with mild pigmentation. The sambar deer orbit is completely encompassed by bone. The ocular histology was very similar to most mammalians. The findings in this study will be useful in the diagnosis of ocular diseases in Rusa unicolor. © 2014 American College of Veterinary Ophthalmologists.

  15. Bony manifestation of rickets in a sunny city - a case report from Yazd, Iran

    Directory of Open Access Journals (Sweden)

    Mohammadhosain Afrand

    2014-01-01

    Full Text Available Rickets is disease that occurs in growing bones in which defective mineralization occurs in both the bone and the cartilage of the epiphyseal growth plate, resulting in the retardation of growth and skeletal deformities. Rickets is more common in areas with less sunlight. However, this case report presents a case of the bony manifestation of rickets with the intake of vitamin D supplements in Yazd, a city in central Iran that has sunshine almost every day. A patient was referred to an out-patient general pediatric clinic for deformities of the legs and growth disturbance, with his height far below the normal range. The changes that were most evident in his X-rays were the bowing of the long bones of the legs and forearms and the cupping of the wrist metaphyseal region. In summary, we present a patient with bony manifestation of rickets despite living in a sunny area and taking vitamin D supplements. Thus, it is important to remember that rickets is still a common disease among children in Iran. More studies of this issue should be conducted, including the identification of abnormal cases and rescheduling vitamin D supplementation programs.

  16. Bony manifestation of rickets in a sunny city - a case report from Yazd, Iran

    Directory of Open Access Journals (Sweden)

    Mohammadhosain Afrand

    2014-02-01

    Full Text Available Rickets is disease that occurs in growing bones in which defective mineralization occurs in both the bone and the cartilage of the epiphyseal growth plate, resulting in the retardation of growth and skeletal deformities. Rickets is more common in areas with less sunlight. However, this case report presents a case of the bony manifestation of rickets with the intake of vitamin D supplements in Yazd, a city in central Iran that has sunshine almost every day. A patient was referred to an out-patient general pediatric clinic for deformities of the legs and growth disturbance, with his height far below the normal range. The changes that were most evident in his X-rays were the bowing of the long bones of the legs and forearms and the cupping of the wrist metaphyseal region. In summary, we present a patient with bony manifestation of rickets despite living in a sunny area and taking vitamin D supplements. Thus, it is important to remember that rickets is still a common disease among children in Iran. More studies of this issue should be conducted, including the identification of abnormal cases and rescheduling vitamin D supplementation programs

  17. Bonding brackets to porcelain: in vitro study

    Directory of Open Access Journals (Sweden)

    Sant'Anna Eduardo Franzotti

    2002-01-01

    Full Text Available The aim of this research was to verify, in vitro, the effect of various porcelain surface treatments on the shear strength of orthodontic brackets bonded to porcelain and the mode of fracture after debonding. Eighty-eight samples of metallic supported feldspathic porcelain were randomly divided into four groups according to their surface preparation as follows: the porcelain was maintained intact (GI, roughened with a diamond bur (GII, etched with 10% hydrofluoric acid (GIII, or sandblasted with aluminum oxide (GIV. The specimens were treated with silane (Scothprime and brackets were bonded with Concise. Each sample was subjected to a shear load at a crosshead speed of 1 mm/min and a recording was made at the point of failure. Bond strengths, adequate to withstand the application of orthodontic forces, were achieved in all groups. The Kruskal-Wallis statistical test showed no significant differences in bond strength between the groups (p>0.05. However, many more porcelain fractures occurred on deglazed porcelain. This study indicates that with the appropriate material selection, the silane/composite procedure alone may be adequate for bonding.

  18. Influence of rotational setup error on tumor shift in bony anatomy matching measured with pulmonary point registration in stereotactic body radiotherapy for early lung cancer

    International Nuclear Information System (INIS)

    Suzuki, Osamu; Nishiyama, Kinji; Ueda, Yoshihiro; Miyazaki, Masayoshi; Tsujii, Katsutomo

    2012-01-01

    The objective of this study was to examine the correlation between the patient rotational error measured with pulmonary point registration and tumor shift after bony anatomy matching in stereotactic body radiotherapy for lung cancer. Twenty-six patients with lung cancer who underwent stereotactic body radiotherapy were the subjects. On 104 cone-beam computed tomography measurements performed prior to radiation delivery, rotational setup errors were measured with point registration using pulmonary structures. Translational registration using bony anatomy matching was done and the three-dimensional vector of tumor displacement was measured retrospectively. Correlation among the three-dimensional vector and rotational error and vertebra-tumor distance was investigated quantitatively. The median and maximum rotational errors of the roll, pitch and yaw were 0.8, 0.9 and 0.5, and 6.0, 4.5 and 2.5, respectively. Bony anatomy matching resulted in a 0.2-1.6 cm three-dimensional vector of tumor shift. The shift became larger as the vertebra-tumor distance increased. Multiple regression analysis for the three-dimensional vector indicated that in the case of bony anatomy matching, tumor shifts of 5 and 10 mm were expected for vertebra-tumor distances of 4.46 and 14.1 cm, respectively. Using pulmonary point registration, it was found that the rotational setup error influences the tumor shift. Bony anatomy matching is not appropriate for hypofractionated stereotactic body radiotherapy with a tight margin. (author)

  19. A biomechanical analysis of a single-row suture anchor fixation of a large bony bankart lesion.

    Science.gov (United States)

    Dyskin, Evgeny; Marzo, John M; Howard, Craig; Ehrensberger, Mark

    2014-12-01

    This study was conducted to assess whether a single-row suture anchor repair of a bony Bankart lesion comprising 19% of the glenoid length restores peak translational force and glenoid depth compared with the intact shoulder. Nine thawed adult cadaveric shoulders were dissected and mounted in 45° of abduction and 30° of external rotation. A bony Bankart lesion was simulated with an anterior longitudinal osteotomy, parallel to the superoinferior axis of the glenoid, equivalent to 19% of the glenoid length. The humeral head was displaced 10 mm anteriorly at a speed of 2 mm/s with a 50-N compressive load applied. Testing was performed with the glenoid intact, a simulated lesion, and the lesion repaired with 3 single-row suture anchors. Median (interquartile range [IQR]) peak translational force and glenoid depth were reported. The Friedman test and post hoc comparisons with the Wilcoxon signed rank test were used for between-group analyses. Peak translational force decreased after osteotomy (13.7 N; IQR, 9.6 to 15.5 N; P = .01) and increased after the repair (18.3 N; IQR, 18.3 to 20.6 N; P = .01) compared with the intact shoulder (23.7 N; IQR, 16.4 to 29.9 N). Glenoid depth significantly decreased after the osteotomy (0.2 mm; IQR, -0.6 to 0.7 mm) compared with baseline (1.7 mm; IQR, 1.3 to 2.0 mm; P = .01) and increased after repair (0.8 mm; IQR, 0.1 to 1.0 mm; P = .03) compared with the osteotomized shoulder. The glenoid depth of the repair was less than the baseline value (P = .01). Repair of an anterior bony Bankart lesion equivalent to 19% of the glenoid length with 3 suture anchors restored the peak translational force needed to anteriorly displace the humerus relative to the glenoid; however, this technique failed to restore the natural glenoid depth in a laboratory setting. Our findings describe the inability of a single-row suture anchor repair to provide anatomic fixation of the bony Bankart lesion equivalent to 19% of the glenoid length

  20. Radiology of Osteogenesis Imperfecta, Rickets and Other Bony Fragility States.

    Science.gov (United States)

    Calder, Alistair D

    2015-01-01

    This section gives an overview of radiological findings in bony fragility states, with a special focus on osteogenesis imperfecta (OI) and rickets. Conventional radiological assessment of bone density is inaccurate and imprecise and only reliably detects severe osteopaenia. However, other aspects of bone structure and morphology can be assessed, and it is possible to distinguish between osteopaenic and osteomalacic states. OI is a heterogeneous group of disorders of type 1 collagen formation and processing that are characterised by varying degrees of bony fragility, with presentations varying from perinatal lethality to asymptomatic. Radiological diagnosis of severe forms is usually straightforward, but that of milder disease may be challenging because specific features are often absent. However, a multidisciplinary approach is usually successful. Features of OI, including Wormian bones, skull base deformities, vertebral involvement and long bone fractures and deformities, are reviewed in this section. Rickets is best defined as a disorder of the growth plate characterised by the impaired apoptosis of hypertrophied chondrocytes. Vitamin D deficiency is a common cause of rickets. The patho-anatomical basis of radiological findings in rickets is reviewed and illustrated. Rickets is frequently accompanied by hyperparathyroidism and osteomalacia. Rickets used to be classified as calciopaenic or phosphopaenic but is now referred to as parathyroid hormone or fibroblast growth factor 23 mediated, respectively [1]. The radiological features of the two forms are reviewed. © 2015 S. Karger AG, Basel.

  1. X-ray and neutron tomography on the bony inner ear of baleen whales

    International Nuclear Information System (INIS)

    Arlt, Tobias; Wieder, Frank; Hampe, Oliver; Manke, Ingo; Ritsche, Indira; Fahlke, Julia M.

    2018-01-01

    During their evolution whales and dolphins developed a highly specialized hearing organ for orientation in their deep sea territory covering a broad acoustic spectrum. The internal anatomy of the periotic bone, especially the morphology of the cochlea, has a significant influence on the hearing capability of mammals. The bony and fossilized cochleae of several fossil representatives of extinct baleen whales (e.g., Cetotheriidae) and modern rorquals (Balaenopteridae) and right whales, as well as cochleae of an archaeocete and some land mammals are investigated by X-ray and neutron tomography in order to record morphological changes that may be responsible for the development of low frequency hearing. Differences in the cochlear morphology have been determined by means of morphometric parameters, such as the number of turns, the length of the cochlea, and the curvature of the cochlear canal. In particular, X-ray tomography enables a high resolution display of the bony inner ear.

  2. Immediate Single-Tooth Implant Placement in Bony Defects in the Esthetic Zone : A 1-Year Randomized Controlled Trial

    NARCIS (Netherlands)

    Slagter, Kirsten W.; Meijer, Henny J. A.; Bakker, Nicolaas A.; Vissink, Arjan; Raghoebar, Gerry M.

    Background: This study aims to assess, with regard to marginal bone level (MBL), whether the outcome of immediate implant placement in bony defects in the esthetic zone was non-inferior to delayed implant placement after 1 year. Methods: Forty patients with a failing tooth in the esthetic zone and a

  3. Oxidation study on as-bonded intermetallic of copper wire–aluminum bond pad metallization for electronic microchip

    International Nuclear Information System (INIS)

    Joseph Sahaya Anand, T.; Yau, Chua Kok; Huat, Lim Boon

    2012-01-01

    In this work, influence of Copper free air ball (FAB) oxidation towards Intermetallic Compound (IMC) at Copper wire–Aluminum bond pad metallization (Cu/Al) is studied. Samples are synthesized with different Copper FAB oxidation condition by turning Forming Gas supply ON and OFF. Studies are performed using Optical Microscope (OM), Scanning Electron Microscope (SEM), Transmission Electron Microscope (TEM) and line-scan Energy Dispersive X-ray (EDX). SEM result shows there is a cross-sectional position offset from center in sample synthesized with Forming Gas OFF. This is due to difficulty of determining the position of cross-section in manual grinding/polishing process and high occurrence rate of golf-clubbed shape of oxidized Copper ball bond. TEM inspection reveals that the Copper ball bond on sample synthesized with Forming Gas OFF is having intermediate oxidation. Besides, the presence of IMC at the bonding interface of Cu/Al for both samples is seen. TEM study shows voids form at the bonding interface of Forming Gas ON sample belongs to unbonded area; while that in Forming Gas OFF sample is due to volume shrinkage of IMC growth. Line-scan EDX shows the phases present in the interfaces of as-bonded samples are Al 4 Cu 9 (∼3 nm) for sample with Forming Gas ON and mixed CuAl and CuAl 2 (∼15 nm) for sample with Forming Gas OFF. Thicker IMC in sample with Forming Gas OFF is due to cross-section is positioned at high stress area that is close to edge of ball bond. Mechanical ball shear test shows that shear strength of sample with Forming Gas OFF is about 19% lower than that of sample with Forming Gas ON. Interface temperature is estimated at 437 °C for as-bonded sample with Forming Gas ON by using empirical parabolic law of volume diffusion. -- Highlights: ► 3 nm Al 4 Cu 9 are found in sample prepared with Forming Gas ON. ► 15 nm mixed CuAl + CuAl 2 are found in sample prepared with Forming Gas OFF. ► Voids are present at the bonding interfaces of both

  4. Oxidation study on as-bonded intermetallic of copper wire-aluminum bond pad metallization for electronic microchip

    Energy Technology Data Exchange (ETDEWEB)

    Joseph Sahaya Anand, T., E-mail: anand@utem.edu.my [Faculty of Manufacturing Engineering, University Technical Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka (Malaysia); Yau, Chua Kok [Faculty of Manufacturing Engineering, University Technical Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka (Malaysia); University of Technical Malaysia Supported by Infineon Technology - Malaysia - Sdn. Bhd., Melaka (Malaysia); Huat, Lim Boon [Department of Innovation, Infineon Technology - Malaysia - Sdn. Bhd., FTZ Batu Berendam, 75350 Melaka (Malaysia)

    2012-10-15

    In this work, influence of Copper free air ball (FAB) oxidation towards Intermetallic Compound (IMC) at Copper wire-Aluminum bond pad metallization (Cu/Al) is studied. Samples are synthesized with different Copper FAB oxidation condition by turning Forming Gas supply ON and OFF. Studies are performed using Optical Microscope (OM), Scanning Electron Microscope (SEM), Transmission Electron Microscope (TEM) and line-scan Energy Dispersive X-ray (EDX). SEM result shows there is a cross-sectional position offset from center in sample synthesized with Forming Gas OFF. This is due to difficulty of determining the position of cross-section in manual grinding/polishing process and high occurrence rate of golf-clubbed shape of oxidized Copper ball bond. TEM inspection reveals that the Copper ball bond on sample synthesized with Forming Gas OFF is having intermediate oxidation. Besides, the presence of IMC at the bonding interface of Cu/Al for both samples is seen. TEM study shows voids form at the bonding interface of Forming Gas ON sample belongs to unbonded area; while that in Forming Gas OFF sample is due to volume shrinkage of IMC growth. Line-scan EDX shows the phases present in the interfaces of as-bonded samples are Al{sub 4}Cu{sub 9} ({approx}3 nm) for sample with Forming Gas ON and mixed CuAl and CuAl{sub 2} ({approx}15 nm) for sample with Forming Gas OFF. Thicker IMC in sample with Forming Gas OFF is due to cross-section is positioned at high stress area that is close to edge of ball bond. Mechanical ball shear test shows that shear strength of sample with Forming Gas OFF is about 19% lower than that of sample with Forming Gas ON. Interface temperature is estimated at 437 Degree-Sign C for as-bonded sample with Forming Gas ON by using empirical parabolic law of volume diffusion. -- Highlights: Black-Right-Pointing-Pointer 3 nm Al{sub 4}Cu{sub 9} are found in sample prepared with Forming Gas ON. Black-Right-Pointing-Pointer 15 nm mixed CuAl + CuAl{sub 2} are found

  5. Enamel Wetness Effects on Microshear Bond Strength of Different Bonding Agents (Adhesive Systems): An in vitro Comparative Evaluation Study.

    Science.gov (United States)

    Kulkarni, Girish; Mishra, Vinay K

    2016-05-01

    The purpose of this study was to compare the effect of enamel wetness on microshear bond strength using different adhesive systems. To evaluate microshear bond strength of three bonding agents on dry enamel; to evaluate microshear bond strength of three bonding agents on wet enamel; and to compare microshear bond strength of three different bonding agents on dry and wet enamel. Sixty extracted noncarious human premolars were selected for this study. Flat enamel surfaces of approximately 3 mm were obtained by grinding the buccal surfaces of premolars with water-cooled diamond disks. This study evaluated one etch-and-rinse adhesive system (Single Bond 2) and two self-etching adhesive systems (Clearfil SE Bond and Xeno-V). The specimens were divided into two groups (n = 30). Group I (dry) was air-dried for 30 seconds and in group II (wet) surfaces were blotted with absorbent paper to remove excess water. These groups were further divided into six subgroups (n = 10) according to the adhesives used. The resin composite, Filtek Z 250, was bonded to flat enamel surfaces that had been treated with one of the adhesives, following the manufacturer's instructions. After being stored in water at 37°C for 24 hours, bonded specimens were stressed in universal testing machine (Fig. 3) at a crosshead speed of 1 mm/min. The data were evaluated with one-way and two-way analysis of variance (ANOVA), t-test, and Tukey's Multiple Post hoc tests (a = 0.05). The two-way ANOVA and Tukey's Multiple Post hoc tests showed significant differences among adhesive systems, but wetness did not influence microshear bond strength (p = 0.1762). The one-way ANOVA and t-test showed that the all-in-one adhesive (Xeno-V) was the only material influenced by the presence of water on the enamel surface. Xeno-V showed significantly higher microshear bond strength when the enamel was kept wet. Single Bond 2 adhesive showed significantly higher microshear bond strength as compared with Xeno-V adhesive but no

  6. Inverted 'V' osteotomy excision arthroplasty for bony ankylosed elbows

    Directory of Open Access Journals (Sweden)

    Rex Chadrabose

    2011-12-01

    Full Text Available Abstract Background Bony ankylosis of elbow is challenging and difficult problem to treat. The options are excision arthroplasty and total elbow replacement. We report our midterm results on nine patients, who underwent inverted 'V' osteotomy excision arthroplasty in our hospital with good functional results. Materials Our case series includes 9 patients (seven males and two females with the mean age of 34 years (13-56 years. Five patients had trauma, two had pyogenic arthritis, one had tuberculous arthritis, and one had pyogenic arthritis following surgical fixation. Results The average duration of follow up is 65 months (45 months-80 months. The mean Mayo's elbow performance score (MEPS preoperatively was 48 (35-70. The MEPS at final follow up was 80 (60-95. With no movement at elbow and fixed in various degrees of either flexion or extension preoperatively, the mean preoperative position of elbow was 64°(30°to 100°. The mean post operative range of motion at final follow up was 27°of extension (20-500, 116°of flexion (1100-1300, and the arc of motion was 88°(800-1000. One patient had ulnar nerve neuropraxia and another patient developed median nerve neuropraxia, and both recovered completely in six weeks. No patient had symptomatic instability of the elbow. All patients were asymptomatic except one patient, who had pain mainly on heavy activities. Conclusion We conclude that inverted 'V' osteotomy excision arthroplasty is a viable option in the treatment of bony ankylosis of the elbow in young patients.

  7. Comparison of shear bond strength of orthodontic brackets bonded using two different hydrophilic primers: An in vitro study

    Directory of Open Access Journals (Sweden)

    M Kumaraswamy Anand

    2014-01-01

    Full Text Available Context: Salivary control and maintenance of a dry operating field is a prime requisite of orthodontic bonding. Moisture insensitive primer (MIP with a clinical significant bond strength values have a better edge over the conventional hydrophobic bonding systems. Aim: The aim of this study is to investigate the effectiveness of two hydrophilic primers with respect to conventional hydrophobic primer by comparing their shear bond strength (SBS and adhesive-failure locations after contamination with saliva and saliva substitute. Materials and Methods: A total of 150 extracted human premolars were randomly divided into five group s ; Group A (Transbond MIP/saliva substitute, Group B (Opal Primo/saliva substitute, Group C (Transbond MIP/natural saliva, Group D (Opal Primo/natural saliva, control group - Group E (Transbond XT/dry, adhesive-Transbond XT used for all five groups and bonded using stainless steel brackets. Shear forces were applied to the samples with a universal testing machine. SBSs was measured in megapascals. The mode of bond failure was determined using the adhesive remnant index (ARI. Results: The mean SBS produced by Transbond MIP was higher than Opal Primo, which was statistically significant according to one-way analysis of variance. Both the tested groups showed lesser bond strength values than Transbond XT (the control. ARI scores revealed that there was no statistically significant difference in the site of bond failure between study groups. ARI scores were found to be lower for study groups suggesting adhesive failure, compared to higher ARI scores for the control group suggesting cohesive failure. Conclusion: Transbond XT adhesive with Transbond MIP or Opal Primo have clinically acceptable bond strength in wet fields. Opal Primo is a viable option to use as a hydrophilic primer clinically.

  8. Neurotrophin-3 Induces BMP-2 and VEGF Activities and Promotes the Bony Repair of Injured Growth Plate Cartilage and Bone in Rats.

    Science.gov (United States)

    Su, Yu-Wen; Chung, Rosa; Ruan, Chun-Sheng; Chim, Shek Man; Kuek, Vincent; Dwivedi, Prem P; Hassanshahi, Mohammadhossein; Chen, Ke-Ming; Xie, Yangli; Chen, Lin; Foster, Bruce K; Rosen, Vicki; Zhou, Xin-Fu; Xu, Jiake; Xian, Cory J

    2016-06-01

    Injured growth plate is often repaired by bony tissue causing bone growth defects, for which the mechanisms remain unclear. Because neurotrophins have been implicated in bone fracture repair, here we investigated their potential roles in growth plate bony repair in rats. After a drill-hole injury was made in the tibial growth plate and bone, increased injury site mRNA expression was observed for neurotrophins NGF, BDNF, NT-3, and NT-4 and their Trk receptors. NT-3 and its receptor TrkC showed the highest induction. NT-3 was localized to repairing cells, whereas TrkC was observed in stromal cells, osteoblasts, and blood vessel cells at the injury site. Moreover, systemic NT-3 immunoneutralization reduced bone volume at injury sites and also reduced vascularization at the injured growth plate, whereas recombinant NT-3 treatment promoted bony repair with elevated levels of mRNA for osteogenic markers and bone morphogenetic protein (BMP-2) and increased vascularization and mRNA for vascular endothelial growth factor (VEGF) and endothelial cell marker CD31 at the injured growth plate. When examined in vitro, NT-3 promoted osteogenesis in rat bone marrow stromal cells, induced Erk1/2 and Akt phosphorylation, and enhanced expression of BMPs (particularly BMP-2) and VEGF in the mineralizing cells. It also induced CD31 and VEGF mRNA in rat primary endothelial cell culture. BMP activity appears critical for NT-3 osteogenic effect in vitro because it can be almost completely abrogated by co-addition of the BMP inhibitor noggin. Consistent with its angiogenic effect in vivo, NT-3 promoted angiogenesis in metatarsal bone explants, an effect abolished by co-treatment with anti-VEGF. This study suggests that NT-3 may be an osteogenic and angiogenic factor upstream of BMP-2 and VEGF in bony repair, and further studies are required to investigate whether NT-3 may be a potential target for preventing growth plate faulty bony repair or for promoting bone fracture healing. © 2016

  9. Evaluation of a New Nano-filled Bonding Agent for Bonding Orthodontic Brackets as Compared to a Conventional Bonding Agent: An in vitro Study

    OpenAIRE

    Sandesh S Pai; Amrita Nagendra; Vinaya S Pai; K Neelima; A E Vishwanath; P Vinod; Sharanya Ajit Kumar; Roopa R Tubaki

    2012-01-01

    Introduction: Recent advances in the field of material sciences have opened up a new horizon of options for bonding agents that can be used efficiently in orthodontics. The purpose of this study was evaluate and compare the shear bond strength (SBS) of the traditionally used Transbond XT and a newer nano-filled material Prime and Bond NT. Materials and methods: Sixty freshly extracted maxillary first premolars were stored in 0.1% (weight/volume) thymol. These were divided into two Groups. ...

  10. Comparative in vitro study of the shear bond strength of brackets bonded with restorative and orthodontic resins

    Directory of Open Access Journals (Sweden)

    Hassan Isber

    2011-02-01

    Full Text Available The aim of this study was to evaluate the shear bond strength of brackets bonded with different restorative systems and compare it with that afforded by an established orthodontic bonding system. Seventy human bicuspids were used, divided into five different groups with 14 teeth each. Whereas a specific orthodontic bonding resin (TransbondTM XT was used in the control group, the restorative systems Charisma, Tetric Ceram, TPH Spectrum and Z100 were used in the other four groups. Seven days after bonding the brackets to the samples, shear forces were applied under pressure in a universal testing machine. The data collected was evaluated using the ANOVA test and, when a difference was identified, the Tukey test was applied. A 5% level of significance was adopted. The mean results of the shear bond strength tests were as follows: Group 1 (Charisma, 14.98 MPa; Group 2 (Tetric Ceram, 15.16 MPa; Group 3 (TPH, 17.70 MPa; Group 4 (Z100, 13.91 MPa; and Group 5 or control group (TransbondTM XT, 17.15 MPa. No statistically significant difference was found among the groups. It was concluded that all tested resins have sufficient bond strength to be recommended for bonding orthodontic brackets.

  11. The Evolution of Bony Vertebrate Enhancers at Odds with Their Coding Sequence Landscape.

    Science.gov (United States)

    Yousaf, Aisha; Sohail Raza, Muhammad; Ali Abbasi, Amir

    2015-08-06

    Enhancers lie at the heart of transcriptional and developmental gene regulation. Therefore, changes in enhancer sequences usually disrupt the target gene expression and result in disease phenotypes. Despite the well-established role of enhancers in development and disease, evolutionary sequence studies are lacking. The current study attempts to unravel the puzzle of bony vertebrates' conserved noncoding elements (CNE) enhancer evolution. Bayesian phylogenetics of enhancer sequences spotlights promising interordinal relationships among placental mammals, proposing a closer relationship between humans and laurasiatherians while placing rodents at the basal position. Clock-based estimates of enhancer evolution provided a dynamic picture of interspecific rate changes across the bony vertebrate lineage. Moreover, coelacanth in the study augmented our appreciation of the vertebrate cis-regulatory evolution during water-land transition. Intriguingly, we observed a pronounced upsurge in enhancer evolution in land-dwelling vertebrates. These novel findings triggered us to further investigate the evolutionary trend of coding as well as CNE nonenhancer repertoires, to highlight the relative evolutionary dynamics of diverse genomic landscapes. Surprisingly, the evolutionary rates of enhancer sequences were clearly at odds with those of the coding and the CNE nonenhancer sequences during vertebrate adaptation to land, with land vertebrates exhibiting significantly reduced rates of coding sequence evolution in comparison to their fast evolving regulatory landscape. The observed variation in tetrapod cis-regulatory elements caused the fine-tuning of associated gene regulatory networks. Therefore, the increased evolutionary rate of tetrapods' enhancer sequences might be responsible for the variation in developmental regulatory circuits during the process of vertebrate adaptation to land. © The Author(s) 2015. Published by Oxford University Press on behalf of the Society for

  12. Comparison of prostate set-up accuracy and margins with off-line bony anatomy corrections and online implanted fiducial-based corrections.

    Science.gov (United States)

    Greer, P B; Dahl, K; Ebert, M A; Wratten, C; White, M; Denham, J W

    2008-10-01

    The aim of the study was to determine prostate set-up accuracy and set-up margins with off-line bony anatomy-based imaging protocols, compared with online implanted fiducial marker-based imaging with daily corrections. Eleven patients were treated with implanted prostate fiducial markers and online set-up corrections. Pretreatment orthogonal electronic portal images were acquired to determine couch shifts and verification images were acquired during treatment to measure residual set-up error. The prostate set-up errors that would result from skin marker set-up, off-line bony anatomy-based protocols and online fiducial marker-based corrections were determined. Set-up margins were calculated for each set-up technique using the percentage of encompassed isocentres and a margin recipe. The prostate systematic set-up errors in the medial-lateral, superior-inferior and anterior-posterior directions for skin marker set-up were 2.2, 3.6 and 4.5 mm (1 standard deviation). For our bony anatomy-based off-line protocol the prostate systematic set-up errors were 1.6, 2.5 and 4.4 mm. For the online fiducial based set-up the results were 0.5, 1.4 and 1.4 mm. A prostate systematic error of 10.2 mm was uncorrected by the off-line bone protocol in one patient. Set-up margins calculated to encompass 98% of prostate set-up shifts were 11-14 mm with bone off-line set-up and 4-7 mm with online fiducial markers. Margins from the van Herk margin recipe were generally 1-2 mm smaller. Bony anatomy-based set-up protocols improve the group prostate set-up error compared with skin marks; however, large prostate systematic errors can remain undetected or systematic errors increased for individual patients. The margin required for set-up errors was found to be 10-15 mm unless implanted fiducial markers are available for treatment guidance.

  13. The significance of a hypoplastic bony canal for the cochlear nerve in patients with sensorineural hearing loss: CT and MRI findings

    International Nuclear Information System (INIS)

    Choi, Yoon Jung; Park, Sang Yoo; Kim, Myung Soon; Sung, Ki Jun

    2004-01-01

    The purpose of this study is to evaluate the significance of the hypoplastic canal for the cochlear nerve in patients with sensorineural hearing loss (SNHL) and the relationship between the hypoplastic bony canal and aplasia or hypoplasia of the cochlear nerve. A retrospective review of high resolution temporal CT(HRCT) and MRI findings was conducted. The narrow bony canal of the cochlear nerve and the relative size of the internal auditory canal were correlated with the cochlear nerve deficiency on MRI. The comparative size of the component nerves (facial, cochlear, superior vestibular, inferior vestibular nerve), and the relative size of the internal auditory canal and the bony canal of the cochlear nerve were measured. The clinical history and the results of the clinical examination were reviewed for each patient. High resolution MRI showed aplasia of the common vestibulocochlear nerve in one patient and a deficiency of the cochlear nerve in 9 patients. These abnormalities occurred in association with a prominent narrowing of the canal for the cochlear nerve and a stenosis of the internal auditory canal, which was observed on temporal bone CT in 9 patients with congenital SNHL. Three patients had normal IAC, despite the presence of a hypoplastic cochlear nerve on the side on which they had SNHL. In one patient, the narrowing of the canal for the cochlear nerve and internal auditory canal were not found to be associated with acquired SNHL. The hypoplastic bony canal for the cochlear nerve might be more highly indicative of congenital cochlear nerve deficiency than that of the narrow internal auditory canal, and the position of the crista falciformis should also be carefully

  14. The significance of a hypoplastic bony canal for the cochlear nerve in patients with sensorineural hearing loss: CT and MRI findings

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yoon Jung; Park, Sang Yoo; Kim, Myung Soon; Sung, Ki Jun [College of Medicine, Yonsei Univ., Wonju (Korea, Republic of)

    2004-04-01

    The purpose of this study is to evaluate the significance of the hypoplastic canal for the cochlear nerve in patients with sensorineural hearing loss (SNHL) and the relationship between the hypoplastic bony canal and aplasia or hypoplasia of the cochlear nerve. A retrospective review of high resolution temporal CT(HRCT) and MRI findings was conducted. The narrow bony canal of the cochlear nerve and the relative size of the internal auditory canal were correlated with the cochlear nerve deficiency on MRI. The comparative size of the component nerves (facial, cochlear, superior vestibular, inferior vestibular nerve), and the relative size of the internal auditory canal and the bony canal of the cochlear nerve were measured. The clinical history and the results of the clinical examination were reviewed for each patient. High resolution MRI showed aplasia of the common vestibulocochlear nerve in one patient and a deficiency of the cochlear nerve in 9 patients. These abnormalities occurred in association with a prominent narrowing of the canal for the cochlear nerve and a stenosis of the internal auditory canal, which was observed on temporal bone CT in 9 patients with congenital SNHL. Three patients had normal IAC, despite the presence of a hypoplastic cochlear nerve on the side on which they had SNHL. In one patient, the narrowing of the canal for the cochlear nerve and internal auditory canal were not found to be associated with acquired SNHL. The hypoplastic bony canal for the cochlear nerve might be more highly indicative of congenital cochlear nerve deficiency than that of the narrow internal auditory canal, and the position of the crista falciformis should also be carefully.

  15. Allergenicity of bony and cartilaginous fish - molecular and immunological properties.

    Science.gov (United States)

    Stephen, J N; Sharp, M F; Ruethers, T; Taki, A; Campbell, D E; Lopata, A L

    2017-03-01

    Allergy to bony fish is common and probably increasing world-wide. The major heat-stable pan-fish allergen, parvalbumin (PV), has been identified and characterized for numerous fish species. In contrast, there are very few reports of allergic reactions to cartilaginous fish despite widespread consumption. The molecular basis for this seemingly low clinical cross-reactivity between these two fish groups has not been elucidated. PV consists of two distinct protein lineages, α and β. The α-lineage of this protein is predominant in muscle tissue of cartilaginous fish (Chondrichthyes), while β-PV is abundant in muscle tissue of bony fish (Osteichthyes). The low incidence of allergic reactions to ingested rays and sharks is likely due to the lack of molecular similarity, resulting in reduced immunological cross-reactivity between the two PV lineages. Structurally and physiologically, both protein lineages are very similar; however, the amino acid homology is very low with 47-54%. Furthermore, PV from ancient fish species such as the coelacanth demonstrates 62% sequence homology to leopard shark α-PV and 70% to carp β-PV. This indicates the extent of conservation of the PV isoforms lineages across millennia. This review highlights prevalence data on fish allergy and sensitization to fish, and details the molecular diversity of the two protein lineages of the major fish allergen PV among different fish groups, emphasizing the immunological and clinical differences in allergenicity. © 2017 John Wiley & Sons Ltd.

  16. [Prevalence and clinical characteristics of oral bony outgrowth in a Moroccan population].

    Science.gov (United States)

    Oualalou, Y; Azaroual, M F; Zaoui, F; Chbicheb, S; Berrada, S

    2014-11-01

    Oral bony outgrowths (OBOs) are localized bony protuberances that arise from the cortical plate. Various types of OBOs have been described, the precise designation of which depends on anatomic location such as torus palatinus, torus mandibularis, buccal exostosis, or palatal exostosis. We had for aim to determine the prevalence and clinical characteristics of OBOs in a Moroccan population. This cross-sectional study was conducted between March 15 and June 30, 2011 at the Rabat-Salé teaching hospital dental consultation and treatment center, in Morocco. Three hundred and fifty-three patients (160 female and 193 male patients), 11 to 82 years of age, were examined clinically and radiologically to determine the presence of OBO. Twenty-four patients (6.8%) presented with OBOs. The prevalence for exostosis, torus mandibularis, torus palatinus, and associated OBOs was 3.1%, 2%, 0.8%, and 0.9% respectively. There was a significant difference (P=0,01) between the average age for patients presenting with OBO (43.2±12 years of age) and the average age for patients without any OBO (36.5±16 years of age). The prevalence of OBOs in female patients (7.3%) was higher than in male patients (6.3%) but the difference was not significant (P=0.439). Patients with occlusal parafunctional activity presented with significantly more OBO (P=0.016). The reported prevalence of OBO is extremely variable, according to age, gender, and ethnic group. The occurrence of OBO could be triggered by genetic factors associated with environmental factors. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  17. Bony vibration stimulation test combined with magnetic resonance imaging. Can discography be replaced?

    Science.gov (United States)

    Yrjämä, M; Tervonen, O; Kurunlahti, M; Vanharanta, H

    1997-04-01

    The results of two noninvasive methods, magnetic resonance imaging and a bony vibration test, were compared with discographic pain provocation findings. To evaluate whether the combination of magnetic resonance imaging and vibration pain provocation tests could be used to replace discography in low back pain diagnostics. Magnetic resonance imaging gives a wealth of visual information on anatomic changes of the spine with often unknown clinical significance. Discographic examination of the spine is still the only widely accepted diagnostic method that can relate the pathoanatomic changes to the patient's clinical pain. Internal anular rupture has been shown to be one of the sources of back pain. The bony vibration test of the spinal processes has been shown correlate well with discographic pain provocation tests in cases of internal anular rupture. The three lowest lumbar discs of 33 patients with back pain were examined by means of magnetic resonance imaging and a bony vibration stimulation test, and the results were compared with those from computed tomography-discography. In cases of intradiscal magnetic resonance imaging findings, the vibration provocation test showed a sensitivity of 0.88 and a specificity of 0.50 compared with the discographic pain provocation test. If the patients with previous back surgery were excluded, the specificity was 0.75. In the cases of total anular rupture, the sensitivity was 0.50, and the specificity was 0.33. The combination of the two noninvasive methods, vibration stimulation and magnetic resonance imaging, gives more information on the origin of the back pain than magnetic resonance imaging alone. The pathoanatomic changes seen in magnetic resonance imaging can be correlated with the patient's disorder more reliably using the vibration provocation test in the cases of partial anular ruptures. The use of discography can be limited mostly to cases with total anular ruptures detected by magnetic resonance imaging.

  18. Valor predicts the thyroid hormones in the evolution the transplant bony marrow

    International Nuclear Information System (INIS)

    Alonso, C.A.; Carnot, J.; De Castro, R.; Morera, M.L.; Garcia, I.

    1998-01-01

    In this work you values the valor I predict the thyroid hormones in the bony marrow transplant evolution as factors the metabolisms oxidative and the synthesis albumins. The patients received conditioning treatments to the transplant and in the postoperational. The received radiations were 1000 cGy lateral cube, with blocking lung, to those that were subjected 3 sessions irradiation, they are practiced a transplant marrow allogeneic

  19. Comparative TEM study of bonded silicon/silicon interfaces fabricated by hydrophilic, hydrophobic and UHV wafer bonding

    International Nuclear Information System (INIS)

    Reznicek, A.; Scholz, R.; Senz, S.; Goesele, U.

    2003-01-01

    Wafers of Czochralski-grown silicon were bonded hydrophilically, hydrophobically and in ultrahigh vacuum (UHV) at room temperature. Wafers bonded hydrophilically adhere together by hydrogen bonds, those bonded hydrophobically by van der Waals forces and UHV-bonded ones by covalent bonds. Annealing the pre-bonded hydrophilic and hydrophobic wafer pairs in argon for 2 h at different temperatures increases the initially low bonding energy. UHV-bonded wafer pairs were also annealed to compare the results. Transmission electron microscopy (TEM) investigations show nano-voids at the interface. The void density depends on the initial bonding strength. During annealing the shape, coverage and density of the voids change significantly

  20. Comparison of the bony remodelling of two synthetic biomaterials: aragonite 55% and aragonite 55% with active substance

    International Nuclear Information System (INIS)

    Oudadesse, H; Derrien, A C; Martin, S; Lucas-Girot, A; Cathelineau, G

    2007-01-01

    In this work, the in vivo behaviour of pure aragonite and vectabone, which is an association of aragonite and an active substance such as gentamicin, was studied to highlight the kinetic resorption of these two biomaterials with 55% of porosity destined for the filling or replacement of bony defects. The synthesis conditions and parameters we used permit us to obtain a biomaterial without a sintering stage. These conditions allow introducing of active substances at the first stage of the elaboration. In this work, the gentamycin antibiotic was associated with calcium carbonate (aragonite 55% with gentamycin) to deliver this active substance on the surgical site for local treatment. The tricalcium phosphate biomaterial was used as the control because of its high biocompatibility. The bony remodelling of these three biomaterials was studied by in vivo experiments. This study was ensured with neutron activation analysis (NAA). The resorption kinetic was elaborated and comparisons of the remodelling biomaterials CaCO 3 55% and CaCO 3 55% with gentamicin (vectabone) and tricalcium phosphate were carried out. The obtained results show that, 6 months after implantation, the mineral composition of vectabone and tricalcium phosphate becomes close to that of young bone. Twelve months after implantation, it becomes similar to that of mature bone

  1. Medial depression with bony dehiscence of lamina papyracea as an anatomic variation: CT evaluation

    International Nuclear Information System (INIS)

    Na, Sun Young; Lee, Young Uk; Youn, Eun Kyung; Suh, Sang Gyung; Kim, Dong Hyun

    1994-01-01

    To evaluate the incidence and CT findings of the medial depression and bony dehiscence of lamina papyracea as an anatomic variation. 1472 PNS CTs of the patients with symptoms of chronic sinusitis were retrospectively evaluated. The total incidence of depressed lamina papyracea as an anatomic variation was 3.5%(52/1472) on PNS CT. There was a statistically significant correlation between the increasing age and the incidence of depressed lamina papyracea. Depression of lamina papyracea anterior to the basal lamella were more common than those of the posterior depression. Associated findings were herniation of adjacent fatty tissue in all cases and the medial bowing and hypertrophied configuration of the medial rectus muscle without significant herniation in 19 cases(34%). Nontraumatic, asymptomatic depression with bony dehiscence of lamina papyracea as an anatomic variation is not uncommon with the incidence of 3.5%. Recognition of its existence and degree may be helpful in avoiding various ocular complication during ethmoid surgery

  2. How and why of orthodontic bond failures: An in vivo study

    Directory of Open Access Journals (Sweden)

    R K Vijayakumar

    2014-01-01

    Full Text Available Introduction: The bonding of orthodontic brackets and their failure rates by both direct and in-direct procedures are well-documented in orthodontic literature. Over the years different adhesive materials and various indirect bonding transfer procedures have been compared and evaluated for bond failure rates. The aim of our study is to highlight the use of a simple, inexpensive and ease of manipulation of a single thermo-plastic transfer tray and the use the of a single light cure adhesive to evaluate the bond failure rates in clinical situations. Materials and Methods: A total of 30 patients were randomly divided into two groups (Group A and Group B. A split-mouth study design was used, for, both the groups so that they were distributed equally with-out bias. After initial prophylaxis, both the procedures were done as per manufactures instructions. All patients were initially motivated and reviewed for bond failures rates for 6 months. Results: Bond failure rates were assessed for over-all direct and indirect procedures, anterior and posterior arches, and for individual tooth. Z-test was used for statistically analyzing, the normal distribution of the sample in a spilt mouth study. The results of the two groups were compared and P value was calculated using Z-proportion test to assess the significance of the bond failure. Conclusion: Over-all bond failure was more for direct bonding. Anterior bracket failure was more in-direct bonding than indirect procedure, which showed more posterior bracket failures. In individual tooth bond failure, mandibular incisor, and premolar brackets showed more failure, followed by maxillary premolars and canines.

  3. Prevalence of bony septa, antral pathology, and dimensions of the maxillary sinus from a sinus augmentation perspective: A retrospective cone-beam computed tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Tadinada, Aditya; Jalali, Elnaz; Al Salman, Wesam; Jambhekar, Shantanu; Katechia, Bina [University of Connecticut, School of Dental Medicine, Farmington (United States); Almas, Khalid [Div. of Periodontology, University of Dammam, College of Dentistry, Dammam (Saudi Arabia)

    2016-06-15

    Sinus elevation procedures have become a routine and reliable way to gain bone volume in the edentulous maxilla for dental implant placement. Presence of bony septations and pathology in the maxillary sinus often cause complications leading to graft or implant failure or both. The aim of this study was to retrospectively evaluate the prevalence of pathology, direction of the septa, and sinus width measured at 2 mm, 5 mm, and 10 mm from the sinus floor in maxillary sinuses using cone-beam computed tomography (CBCT). Seventy-two sinuses from 36 random preoperative CBCT scans referred for implant therapy were retrospectively evaluated for the number, prevalence, and direction of bony septations and presence of pathology. Width of the sinus was also measured at 2 mm, 5 mm, and 10 mm from the sinus floor to account for the amount of bone available for implant placement. Maxillary sinus septa were found in 59.7%. Presence of a single septum was noted in 20 sinuses (27.7%), followed by two septa in 17 sinuses. The most common direction of the septum was the transverse direction. Retention pseudocyst and mucosal thickening were the most commonly seen abnormality/pathology. Based on the high prevalence of septa and sinus pathology in this sample, a preoperative CBCT scan might be helpful in minimizing complications during sinus augmentation procedures for dental implant therapy.

  4. Prevalence of bony septa, antral pathology, and dimensions of the maxillary sinus from a sinus augmentation perspective: A retrospective cone-beam computed tomography study

    International Nuclear Information System (INIS)

    Tadinada, Aditya; Jalali, Elnaz; Al Salman, Wesam; Jambhekar, Shantanu; Katechia, Bina; Almas, Khalid

    2016-01-01

    Sinus elevation procedures have become a routine and reliable way to gain bone volume in the edentulous maxilla for dental implant placement. Presence of bony septations and pathology in the maxillary sinus often cause complications leading to graft or implant failure or both. The aim of this study was to retrospectively evaluate the prevalence of pathology, direction of the septa, and sinus width measured at 2 mm, 5 mm, and 10 mm from the sinus floor in maxillary sinuses using cone-beam computed tomography (CBCT). Seventy-two sinuses from 36 random preoperative CBCT scans referred for implant therapy were retrospectively evaluated for the number, prevalence, and direction of bony septations and presence of pathology. Width of the sinus was also measured at 2 mm, 5 mm, and 10 mm from the sinus floor to account for the amount of bone available for implant placement. Maxillary sinus septa were found in 59.7%. Presence of a single septum was noted in 20 sinuses (27.7%), followed by two septa in 17 sinuses. The most common direction of the septum was the transverse direction. Retention pseudocyst and mucosal thickening were the most commonly seen abnormality/pathology. Based on the high prevalence of septa and sinus pathology in this sample, a preoperative CBCT scan might be helpful in minimizing complications during sinus augmentation procedures for dental implant therapy

  5. Comparison of shear bond strength of the stainless steel metallic brackets bonded by three bonding systems

    Directory of Open Access Journals (Sweden)

    Mehdi Ravadgar

    2013-09-01

    Full Text Available Introduction: In orthodontic treatment, it is essential to establish a satisfactory bond between enamel and bracket. After the self-etch primers (SEPs were introduced for the facilitation of bracket bonding in comparison to the conventional etch-and-bond system, multiple studies have been carried out on their shear bond strengths which have yielded different results. This study was aimed at comparing shear bond strengths of the stainless steel metallic brackets bonded by three bonding systems. Methods: In this experimental in vitro study, 60 extracted human maxillary premolar teeth were randomly divided into three equal groups: in the first group, Transbond XT (TBXT light cured composite was bonded with Transbond plus self-etching primer (TPSEP in the second group, TBXT composite was bonded with the conventional method of acid etching and in the third group, the self cured composite Unite TM bonding adhesive was bonded with the conventional method of acid etching. In all the groups, Standard edgewise-022 metallic brackets (American Orthodontics, Sheboygan, USA were used. Twenty-four hours after the completion of thermocycling, shear bond strength of brackets was measured by Universal Testing Machine (Zwick. In order to compare the shear bond strengths of the groups, the variance analysis test (ANOVA was adopted and p≤0.05 was considered as a significant level. Results: Based on megapascal, the average shear bond strength for the first, second, and third groups was 8.27±1.9, 9.78±2, and 8.92±2.5, respectively. There was no significant difference in the shear bond strength of the groups. Conclusions: Since TPSEP shear bond strength is approximately at the level of the conventional method of acid etching and within the desirable range for orthodontic brackets shear bond strength, applying TPSEP can serve as a substitute for the conventional method of etch and bond, particularly in orthodontic operations.

  6. Comparison of shear bond strength of the stainless steel metallic brackets bonded by three bonding systems

    Directory of Open Access Journals (Sweden)

    Mehdi Ravadgar

    2013-09-01

    Full Text Available Introduction: In orthodontic treatment, it is essential to establish a satisfactory bond between enamel and bracket. After the self-etch primers (SEPs were introduced for the facilitation of bracket bonding in comparison to the conventional etch-and-bond system, multiple studies have been carried out on their shear bond strengths which have yielded different results. This study was aimed at comparing shear bond strengths of the stainless steel metallic brackets bonded by three bonding systems. Methods: In this experimental in vitro study, 60 extracted human maxillary premolar teeth were randomly divided into three equal groups: in the first group, Transbond XT (TBXT light cured composite was bonded with Transbond plus self-etching primer (TPSEP; in the second group, TBXT composite was bonded with the conventional method of acid etching; and in the third group, the self cured composite Unite TM bonding adhesive was bonded with the conventional method of acid etching. In all the groups, Standard edgewise-022 metallic brackets (American Orthodontics, Sheboygan, USA were used. Twenty-four hours after the completion of thermocycling, shear bond strength of brackets was measured by Universal Testing Machine (Zwick. In order to compare the shear bond strengths of the groups, the variance analysis test (ANOVA was adopted and p≤0.05 was considered as a significant level. Results: Based on megapascal, the average shear bond strength for the first, second, and third groups was 8.27±1.9, 9.78±2, and 8.92±2.5, respectively. There was no significant difference in the shear bond strength of the groups. Conclusions: Since TPSEP shear bond strength is approximately at the level of the conventional method of acid etching and within the desirable range for orthodontic brackets shear bond strength, applying TPSEP can serve as a substitute for the conventional method of etch and bond, particularly in orthodontic operations.

  7. "Sub Specie Boni": The Comfort Zone of Self-Belief--A Dimension in Counseling Offenders.

    Science.gov (United States)

    Church, James Lee

    1996-01-01

    Claims that self-defeating behavior is a rational attempt to satisfy early, introjected messages about the type of person one is, arising from a desire for things perceived as good--sub specie boni. Examines the notion of the comfort zone, toxic shame, and therapists' responsibility to nourish acceptable joy. (RJM)

  8. A study of roll-bonding MS90 alloy to steel utilizing chromized interlayer

    International Nuclear Information System (INIS)

    Tolaminejad, B.; Arabi, H.

    2008-01-01

    This article describes a study of the application of a roll bonding technique to MS90(CuZn10) alloy strips and steel sheets using a chromized interlayer. It was found that the overall bond between these two metals resulted from two different types of bonds: a block bond, linking the MS90 alloy strips and chromium topcoat layer, and a blank bond, linking the MS90 alloy strips and bare steel surface in the area where the chromium coating has been fragmented. This study investigated the effects of plating time on the thickness of the coating layers and of the area fraction of the blank bond on the bond strength. The overall bond strength depends mainly on the strength and the area fraction of the blank bond. A linear relationship model exists between the overall bond strength and the area fraction of the blank bond. The bond strength of the blank bond was eight times greater than that of the block bond. The area fraction of the blank bond increased with increasing the coating thickness up to 55 μm, but thereafter decreased due to the rotation of the chromium blocks

  9. Bony landmark between the attachment of the medial meniscus posterior root and the posterior cruciate ligament: CT and MR imaging assessment

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Masataka; Furumatsu, Takayuki; Miyazawa, Shinichi; Kodama, Yuya; Hino, Tomohito; Kamatsuki, Yusuke; Ozaki, Toshifumi [Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Department of Orthopaedic Surgery, Science of Functional Recovery and Reconstruction, Okayama (Japan)

    2017-08-15

    (1) To reveal the prevalence of the bony recess (posterior dimple) and (2) to determine the position of the posterior dimple on the tibial plateau using three-dimensional computed tomography (3DCT). In this study, a retrospective review of 112 patients was performed to identify the posterior dimple and to evaluate its position on 3DCT. Magnetic resonance images (MRIs) were also used to determine the positional relationship among the posterior cruciate ligament (PCL), medial meniscus posterior insertion (MMPI), and posterior dimple. The posterior dimple was observed in 100 of 112 knees (89.3%) on 3DCT. The center of the posterior dimple was 13.6 ± 0.8 mm from the medial tibial eminence apex. MRI showed that the posterior dimple separated the tibial attachment of the PCL and MMPI. This is the first study to discuss the prevalence and position of the bony recess in the posterior intercondylar fossa. (orig.)

  10. Bony landmark between the attachment of the medial meniscus posterior root and the posterior cruciate ligament: CT and MR imaging assessment

    International Nuclear Information System (INIS)

    Fujii, Masataka; Furumatsu, Takayuki; Miyazawa, Shinichi; Kodama, Yuya; Hino, Tomohito; Kamatsuki, Yusuke; Ozaki, Toshifumi

    2017-01-01

    (1) To reveal the prevalence of the bony recess (posterior dimple) and (2) to determine the position of the posterior dimple on the tibial plateau using three-dimensional computed tomography (3DCT). In this study, a retrospective review of 112 patients was performed to identify the posterior dimple and to evaluate its position on 3DCT. Magnetic resonance images (MRIs) were also used to determine the positional relationship among the posterior cruciate ligament (PCL), medial meniscus posterior insertion (MMPI), and posterior dimple. The posterior dimple was observed in 100 of 112 knees (89.3%) on 3DCT. The center of the posterior dimple was 13.6 ± 0.8 mm from the medial tibial eminence apex. MRI showed that the posterior dimple separated the tibial attachment of the PCL and MMPI. This is the first study to discuss the prevalence and position of the bony recess in the posterior intercondylar fossa. (orig.)

  11. Ultrasonographic assessment of tendon thickness, Doppler activity and bony spurs of the elbow in patients with lateral epicondylitis and healthy subjects: a reliability and agreement study.

    Science.gov (United States)

    Krogh, T P; Fredberg, U; Christensen, R; Stengaard-Pedersen, K; Ellingsen, T

    2013-10-01

    Tennis elbow, also known as lateral epicondylitis (LE), is a common disorder often assessed by ultrasound. The aim of this study was to evaluate the ultrasonographic outcomes and methods used in LE research and clinical practice. This study was designed as an intra- and interobserver reliability and agreement study. Ultrasonographic examination of the common extensor tendon of the elbow was performed. The intraobserver study examined tendon thickness twice in 20 right elbows from 20 healthy individuals at an interval of 7 to 12 days. The interobserver study examined tendon thickness, color Doppler activity, and bony spurs in 18 right elbows in 9 healthy individuals and 9 patients with LE. Two trained rheumatologists performed the interobserver examinations with the same scanner on the same day. The main outcomes were intra- and interclass correlation (ICC) and agreement. In the intraobserver study, the ICC with regard to tendon thickness ranged from 0.76 to 0.81, depending on the measurement techniques used. The agreement ranged from 0.06 to 0.13 mm. In the interobserver study, the tendon thickness ICC ranged from 0.45 to 0.65 and the agreement ranged from -0.17 to 0.13 mm. The ICC for color Doppler activity was 0.93, with agreement in 14/18 (78 %) of the cases. A perfect reliability was demonstrated for bony spurs, with an ICC of 1 and exact agreement in 18/18 (100 %) of the cases. Good to excellent reliability was obtained for all measurements. The ultrasonographic techniques evaluated in this trial can be recommended for use in both research and clinical practice. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Comparison of prostate set-up accuracy and margins with off-line bony anatomy corrections and online implanted fiducial-based corrections

    International Nuclear Information System (INIS)

    Greer, P. B.; Dahl, K.; Ebert, M. A.; Wratten, C.; White, M.; Denham, K. W.

    2008-01-01

    Full text: The aim of the study was to determine prostate set-up accuracy and set-up margins with off-line bony anatomy-based imaging protocols, compared with online implanted fiducial marker-based imaging with daily corrections. Eleven patients were treated with implanted prostate fiducial markers and online set-up corrections. Pretreatment orthogonal electronic portal images were acquired to determine couch shifts and verification images were acquired during treatment to measure residual set-up error. The prostate set-up errors that would result from skin marker set-up, off-line bony anatomy-based protocols and online fiducial marker-based corrections were determined. Set-up margins were calculated for each set-up technique using the percentage of encompassed isocentres land a margin recipe. The prostate systematic set-up errors in the medial-lateral, superior-inferior and anterior-I posterior directions for skin marker set-up were 2.2, 3.6 and 4.5 mm (1 standard deviation). For our bony anatomy-I based off-line protocol the prostate systematic set-up errors were 1.6, 2.5 and 4.4 mm. For the online fiducial based set-up the results were 0.5, 1.4 and 1.4 mm. A prostate systematic error of 10.2 mm was uncorrected by the off-line bone protocol in one patient. Set-up margins calculated to encompass 98% of prostate set-up shifts were 111-14 mm with bone off-line set-up and 4-7 mm with online fiducial markers. Margins from the van Herk margin I recipe were generally 1-2 mm smaller. Bony anatomy-based set-up protocols improve the group prostate set-up error compared with skin marks; however, large prostate systematic errors can remain undetected or systematic (errors increased for individual patients. The margin required for set-up errors was found to be 10-15 mm unless I implanted fiducial markers are available for treatment guidance.

  13. A clinical study on the efficacy of hydroxyapatite - Bioactive glass composite granules in the management of periodontal bony defects

    Directory of Open Access Journals (Sweden)

    Tirthankar Debnath

    2014-01-01

    Full Text Available Background: In periodontal regeneration, several alloplastic materials are being used with a goal to reconstruct new osseous tissue in the infrabony defect sites. The present study was undertaken to evaluate the efficacy of hydroxyapatite-bioactive glass (HA:BG composite granules in the management of periodontal bony defects. Materials and Methods: A randomized control study was conducted. Subjects with infrabony defects were divided into three groups. Test Group 1 (n = 10: Defect site was treated with HA:BG, with a biodegradable membrane. Test Group 2 (n = 10: Defect site was treated with HAP, with a biodegradable membrane. Control group (n = 10: Defect site was treated with open flap debridement with a biodegradable membrane Results: The healing of defects was uneventful and free of any biological complications. The gain in clinical attachment level, reduction of probing pocket depth, and defect fill were statistically significant in all three groups. TG1 sites showed significant defect fill than TG2 and CG sites. Conclusion: The performance of HA:BG was better compared to HAP and open flap debridement for the reconstruction of infrabony defects.

  14. Myelotoxicity of Samarium Sm153 lexidronam in patients with painful bony metastases

    International Nuclear Information System (INIS)

    Ben Ghachem, T.; Mhiri, A.; Slim, I.; Bahloul, A.; Yeddes, I.; Elbez, I.; Meddeb, I.; Ben Slimene, M.F.

    2015-01-01

    Full text of publication follows. Introduction: the management of bone pain includes analgesia, radiation, hormones, radiofrequency (RF) ablation, chemotherapy, and surgery. Bone pain palliation therapy with radiopharmaceuticals is a cost-effective systemic therapy to relieve pain from skeletal metastases with a consequent decrease in morbidity and an improvement in quality of life. The aim of our study is to evaluate the effect of myelotoxicity of samarium lexidronam (Sm 153 ) in patients with painful bony metastasis. Methods: we reviewed 116 patients aged from 14 to 87 years old, 91 males (78%) and 25 females (22%), having received 1 to 4 treatments of Sm 153 (37 MBq/kg) for painful bony metastases from different primitive tumors: 67 cases of prostate cancer (57.7%), 22 cases of breast cancer (18.9%), 10 cases of pulmonary cancer (8.6%) and others in 14.6% of cases. Clinical follow-up was available for 159 treatments, consisting on blood count each week over at least two months, in order to evaluate myelotoxicity according to WHO classification. Results: no patients had grade 4 toxicity after its cures. A grade 2-3 myelotoxicity was observed after 52 treatments (34%) during the second week and after 50 treatments (32.6%) during the fourth week with a satisfactory reversibility. At 10 weeks of treatment, myelotoxicity was reclassified from 0 to 2 for 139 cures (90,8%). Moreover, we found that prior treatment with radiotherapy or chemotherapy did not affect the rates of myelotoxicity. Conclusion: multiple treatments with samarium Sm 153 lexidronam had no significant effect on myelotoxicity. Patients with bone predominant metastatic disease may survive for extended periods of time and may safely be treated with multiple modalities of therapy. (authors)

  15. Arthroscopic Suture Anchor Fixation of Bony Bankart Lesions: Clinical Outcome, Magnetic Resonance Imaging Results, and Return to Sports.

    Science.gov (United States)

    Plath, Johannes E; Feucht, Matthias J; Bangoj, Robert; Martetschläger, Frank; Wörtler, Klaus; Seppel, Gernot; Aboalata, Mohamed; Tischer, Thomas; Imhoff, Andreas B; Vogt, Stephan

    2015-08-01

    The purpose of this study was to evaluate the outcome, return to sporting activity, and postoperative articular cartilage and bony morphology of shoulders that underwent arthroscopic suture anchor repair of bony Bankart lesions. The inclusion criteria for this retrospective study were anterior glenoid rim fractures after traumatic shoulder instability that were treated with arthroscopic suture anchor repair. Patients were surveyed by a questionnaire including sport-specific outcome, Rowe score, Western Ontario Shoulder Instability Index, and Oxford Instability Score. Three-tesla magnetic resonance imaging could be performed in 30 patients to assess osseous integration, glenoid reconstruction, and signs of osteoarthritis. From November 1999 to April 2010, 81 patients underwent an anterior bony Bankart repair in our department (50 arthroscopic suture anchor repairs, 5 arthroscopic screw fixations, and 26 open repairs). The 55 arthroscopic repairs comprised a consecutive cohort of patients treated by a single surgeon. Of the 50 patients in the suture anchor group, 45 (90%) were available for evaluation. At 82 ± 31 months postoperatively, the mean Rowe score was 85.9 ± 20.5 points, the mean Western Ontario Shoulder Instability Index score was 89.4% ± 14.7%, and the mean Oxford Instability Score was 13.6 ± 5.4 points. Compared with the contralateral shoulder, all scores showed a significantly reduced outcome (P sporting activity after surgery. The number of sports disciplines (P < .001), duration (P = .005), level (P = .02), and risk category (P = .013) showed a significant reduction compared with the pretrauma condition. However, only 19% of patients reported that shoulder complaints were the reason for the reduction in activity. Nonunion occurred in 16.6%, with a higher frequency in patients with chronic lesions (P = .031). Anatomic reduction was achieved in 72%, the medial step-off in patients with nonanatomic reduction averaged 1.8 ± 0.9 mm, and the

  16. Evaluation of a New Nano-filled Bonding Agent for Bonding Orthodontic Brackets as Compared to a Conventional Bonding Agent: An in vitro Study

    Directory of Open Access Journals (Sweden)

    Sandesh S Pai

    2012-01-01

    Conclusion: Although both bonding agents provide clinically acceptable levels of bond strength, the technique to bond the nano-filled Prime and Bond NT is more cumbersome as compared to the Transbond XT material, which makes the latter a more popular choice in the clinical set up. If the application procedures for the Prime and Bond NT can be simplified then it could be a convenient option in the orthodontic practice.

  17. Experimental and Theoretical Studies in Hydrogen-Bonding Organocatalysis

    Directory of Open Access Journals (Sweden)

    Matej Žabka

    2015-08-01

    Full Text Available Chiral thioureas and squaramides are among the most prominent hydrogen-bond bifunctional organocatalysts now extensively used for various transformations, including aldol, Michael, Mannich and Diels-Alder reactions. More importantly, the experimental and computational study of the mode of activation has begun to attract considerable attention. Various experimental, spectroscopic and calculation methods are now frequently used, often as an integrated approach, to establish the reaction mechanism, the mode of activation or explain the stereochemical outcome of the reaction. This article comprises several case studies, sorted according to the method used in their study. The aim of this review is to give the investigators an overview of the methods currently utilized for mechanistic investigations in hydrogen-bonding organocatalysis.

  18. Effect of ethanol-wet-bonding technique on resin–enamel bonds

    Directory of Open Access Journals (Sweden)

    Muhammet Kerim Ayar

    2014-03-01

    Conclusion: The ethanol-wet-bonding technique may increase the bond strength of commercial adhesives to enamel. The chemical composition of the adhesives can affect the bond strength of adhesives when bonding to acid-etched enamel, using the ethanol-wet-bonding technique. Some adhesive systems used in the present study may simultaneously be applied to enamel and dentin using ethanol-wet-bonding. Furthermore, deploying ethanol-wet-bonding for the tested commercial adhesives to enamel can increase the adhesion abilities of these adhesives to enamel.

  19. Laser etching of enamel for direct bonding - An in vitro study

    Directory of Open Access Journals (Sweden)

    Rajesh K Reddy

    2010-01-01

    Full Text Available The aim of the study was to determine the shear bond strength of mesh shaped stainless steel orthodontic brackets, bonded to acid etched enamel and laser etched enamel and to compare the shear bond strength following acid etching and laser etching. 50 non carious extracted premolar teeth divided in to 5 groups of 10 each were employed in the study. The buccal surfaces of group - I were subjected to conventional etching using 37% phosphoric acid for 30 seconds, while the other four groups were subjected to Nd:YAG laser etching at different power settings of 80mj, 100mj, 150mj and 200mj respectively for 15 seconds. Brackets were later bonded on to these teeth using Ultimate- light curing primer and adhesive. The shear bond strength of each sample was determined using a universal testing machine and the results were evaluated.

  20. Biomechanical Comparison of Arthroscopic Single- and Double-Row Repair Techniques for Acute Bony Bankart Lesions.

    Science.gov (United States)

    Spiegl, Ulrich J; Smith, Sean D; Todd, Jocelyn N; Coatney, Garrett A; Wijdicks, Coen A; Millett, Peter J

    2014-08-01

    Single- and double-row arthroscopic reconstruction techniques for acute bony Bankart lesions have been described in the literature. The double-row fixation technique would provide superior reduction and stability of a simulated bony Bankart lesion at time zero in a cadaveric model compared with the single-row technique. Controlled laboratory study. Testing was performed on 14 matched pairs of glenoids with simulated bony Bankart fractures with a defect width of 25% of the glenoid diameter. Half of the fractures were repaired with a double-row technique, while the contralateral glenoids were repaired with a single-row technique. The quality of fracture reduction was measured with a coordinate measuring machine. To determine the biomechanical stability of the repairs, specimens were preconditioned with 10 sinusoidal cycles between 5 and 25 N at 0.1 Hz and then pulled to failure in the anteromedial direction at a rate of 5 mm/min. Loads at 1 mm and 2 mm of fracture displacement were determined. The double-row technique required significantly higher forces to achieve fracture displacements of 1 mm (mean, 60.6 N; range, 39.0-93.3 N; P = .001) and 2 mm (mean, 94.4 N; range, 43.4-151.2 N; P = .004) than the single-row technique (1 mm: mean, 30.2 N; range, 14.0-54.1 N and 2 mm: mean, 63.7 N; range, 26.6-118.8 N). Significantly reduced fracture displacement was seen after double-row repair for both the unloaded condition (mean, 1.1 mm; range, 0.3-2.4 mm; P = .005) and in response to a 10-N anterior force applied to the defect (mean, 1.6 mm; range, 0.5-2.7 mm; P = .001) compared with single-row repair (unloaded: mean, 2.1 mm; range, 1.3-3.4 mm and loaded: mean, 3.4 mm; range, 1.9-4.7 mm). The double-row fixation technique resulted in improved fracture reduction and superior stability at time zero in this cadaveric model. This information may influence the surgical technique used to treat large osseous Bankart fractures and the postoperative rehabilitation protocols

  1. Amalgam shear bond strength to dentin using different bonding agents.

    Science.gov (United States)

    Vargas, M A; Denehy, G E; Ratananakin, T

    1994-01-01

    This study evaluated the shear bond strength of amalgam to dentin using five different bonding agents: Amalgambond Plus, Optibond, Imperva Dual, All-Bond 2, and Clearfil Liner Bond. Flat dentin surfaces obtained by grinding the occlusal portion of 50 human third molars were used for this study. To contain the amalgam on the tooth surface, cylindrical plastic molds were placed on the dentin and secured with sticky wax. The bonding agents were then applied according to the manufacturers' instructions or light activated and Tytin amalgam was condensed into the plastic molds. The samples were thermocycled and shear bond strengths were determined using an Instron Universal Testing Machine. Analysis by one-way ANOVA indicated significant difference between the five groups (P < 0.05). The bond strength of amalgam to dentin was significantly higher with Amalgambond Plus using the High-Performance Additive than with the other four bonding agents.

  2. Microtensile dentin bond strength of fifth with five seventh-generation dentin bonding agents after thermocycling: An in vitro study

    Directory of Open Access Journals (Sweden)

    Bruhvi Poptani

    2012-01-01

    Full Text Available Objectives: The objective of this in vitro study was to compare the microtensile dentin bond strength (μTBS of five seventh-generation dentin bonding agents (DBA with fifth-generation DBA before and after thermocycling. Materials and Methods: Ten extracted teeth were assigned to fifth generation control group (optibond solo and each of the five experimental groups namely, Group I (G-Bond ,Group II (S 3 Clearfil, Group III (One Coat 7.0, Group IV (Xeno V, and Group V (Optibond all in one. The crown portions of the teeth were horizontally sectioned below the central groove to expose the dentin. The adhesive resins from all groups were bonded to the teeth with their respective composites. Specimens of sizes 1 × 1 × 6 mm 3 were obtained. Fifty specimens that bonded to dentin from each group were selected. Twenty-five of the specimens were tested for debonding without thermocycling and the remaining were subjected to thermocycling followed by μTBS testing. The data were analyzed with one-way ANOVA and Dunnett′s-test for comparison with the reference group(Vth Generation. Results: There was no significant difference (P > 0.05 between the fifth- and seventh-generation adhesives before and after thermocycling. The results of our study showed significantly higher value (P < 0.05 of μTBS of seventh-generation Group II (Clearfil S 3 compared to the fifth-generation before and after thermocycling. Conclusion: The study demonstrated that the Clearfil S 3 bond had the highest μTBS values. In addition, of the five tested seventh-generation adhesive resins were comparable to the fifth-generation DBA.

  3. Infrared matrix isolation study of hydrogen bonds involving C-H bonds: Substituent effects

    International Nuclear Information System (INIS)

    Jeng, M.L.H.; Ault, B.S.

    1989-01-01

    The matrix isolation technique combined with infrared spectroscopy has been employed to isolate and characterize hydrogen-bonded complexes between a series of substituted alkynes and several oxygen and nitrogen bases. Distinct evidence for hydrogen bond formation was observed in each case, with a characteristic red shift of the hydrogen stretching motion ν r . Shifts between 100 and 300 cm -1 were observed, the largest being for the complex of CF 3 CCH with (CH 3 ) 3 N. The perturbed carbon-carbon triple bond stretching vibration was observed for most complexes, as was the alkynic hydrogen bending motion. Attempts were made to correlate the magnitude of the red shift of ν s with substituent constants for the different substituted alkynes; a roughly linear correlation was found with the Hammett σ parameter. Lack of correlation Δν s with either σ 1 or σ R alone suggests that both inductive and resonance contributions to the strength of the hydrogen-bonding interaction are important

  4. The Nature of the Idealized Triple Bonds Between Principal Elements and the σ Origins of Trans-Bent Geometries-A Valence Bond Study.

    Science.gov (United States)

    Ploshnik, Elina; Danovich, David; Hiberty, Philippe C; Shaik, Sason

    2011-04-12

    We describe herein a valence bond (VB) study of 27 triply bonded molecules of the general type X≡Y, where X and Y are main element atoms/fragments from groups 13-15 in the periodic table. The following conclusions were derived from the computational data: (a) Single π-bond and double π-bond energies for the entire set correlate with the "molecular electronegativity", which is the sum of the X and Y electronegativites for X≡Y. The correlation with the molecular electronegativity establishes a simple rule of periodicity: π-bonding strength generally increases from left to right in a period and decreases down a column in the periodic table. (b) The σ frame invariably prefers trans bending, while π-bonding gets destabilized and opposes the trans distortion. In HC≡CH, the π-bonding destabilization overrides the propensity of the σ frame to distort, while in the higher row molecules, the σ frame wins out and establishes trans-bent molecules with 2(1)/2 bonds, in accord with recent experimental evidence based on solid state (29)Si NMR of the Sekiguchi compound. Thus, in the trans-bent molecules "less bonds pay more". (c) All of the π bonds show significant bonding contributions from the resonance energy due to covalent-ionic mixing. This quantity is shown to correlate linearly with the corresponding "molecular electronegativity" and to reflect the mechanism required to satisfy the equilibrium condition for the bond. The π bonds for molecules possessing high molecular electronegativity are charge-shift bonds, wherein bonding is dominated by the resonance energy of the covalent and ionic forms, rather than by either form by itself.

  5. Hydrogen bonds and heat diffusion in α-helices: a computational study.

    Science.gov (United States)

    Miño, German; Barriga, Raul; Gutierrez, Gonzalo

    2014-08-28

    Recent evidence has shown a correlation between the heat diffusion pathways and the known allosteric communication pathways in proteins. Allosteric communication in proteins is a central, yet unsolved, problem in biochemistry, and the study and characterization of the structural determinants that mediate energy transfer among different parts of proteins is of major importance. In this work, we characterized the role of hydrogen bonds in diffusivity of thermal energy for two sets of α-helices with different abilities to form hydrogen bonds. These hydrogen bonds can be a constitutive part of the α-helices or can arise from the lateral chains. In our in vacuo simulations, it was observed that α-helices with a higher possibility of forming hydrogen bonds also had higher rates of thermalization. Our simulations also revealed that heat readily flowed through atoms involved in hydrogen bonds. As a general conclusion, according to our simulations, hydrogen bonds fulfilled an important role in heat diffusion in structural patters of proteins.

  6. Clinical trial and in-vitro study comparing the efficacy of treating bony lesions with allografts versus synthetic or highly-processed xenogeneic bone grafts

    DEFF Research Database (Denmark)

    Kubosch, Eva Johanna; Bernstein, Anke; Wolf, Laura

    2016-01-01

    BACKGROUND: Our study aim was to compare allogeneic cancellous bone (ACB) and synthetic or highly-processed xenogeneic bone substitutes (SBS) in the treatment of skeletal defects in orthopedic surgery. METHODS: 232 patients treated for bony lesions with ACB (n = 116) or SBS (n = 116) within a 10......-year time period were included in this case-control study. Furthermore, both materials were seeded with human osteoblasts (hOB, n = 10) and analyzed by histology, for viability (AlamarBlue®) and protein expression activity (Luminex®). RESULTS: The complication rate was 14.2 %, proportion of defects....... Histological examination revealed similar bone structures, whereas cell remnants were apparent only in the allografts. Both materials were biocompatible in-vitro, and seeded with human osteoblasts. The cells remained vital over the 3-week culture period and produced microscopically typical bone matrix. We...

  7. Bony cranial ornamentation linked to rapid evolution of gigantic theropod dinosaurs

    Science.gov (United States)

    Gates, Terry A.; Organ, Chris; Zanno, Lindsay E.

    2016-09-01

    Exaggerated cranial structures such as crests and horns, hereafter referred to collectively as ornaments, are pervasive across animal species. These structures perform vital roles in visual communication and physical interactions within and between species. Yet the origin and influence of ornamentation on speciation and ecology across macroevolutionary time scales remains poorly understood for virtually all animals. Here, we explore correlative evolution of osseous cranial ornaments with large body size in theropod dinosaurs using a phylogenetic comparative framework. We find that body size evolved directionally toward phyletic giantism an order of magnitude faster in theropod species possessing ornaments compared with unadorned lineages. In addition, we find a body mass threshold below which bony cranial ornaments do not originate. Maniraptoriform dinosaurs generally lack osseous cranial ornaments despite repeatedly crossing this body size threshold. Our study provides novel, quantitative support for a shift in selective pressures on socio-sexual display mechanisms in theropods coincident with the evolution of pennaceous feathers.

  8. Quantitative computed tomography as a test of endurance for evaluation of bony plates; Utilizacao da tomografia computadorizada quantitativa como teste de resistencia para avaliacao de placas osseas

    Energy Technology Data Exchange (ETDEWEB)

    Melo Filho, E.V.; Costa, L.A.V.S.; Oliveira, D.C. [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil); Freitas, P.M.C. [Escola de Veterinaria - Universidade Federal de Minas Gerais - Belo Horizonte, MG (Brazil); Teixeira, M.W.; Costa, F.S. [Universidade Federal Rural de Pernambuco - Recife, PE (Brazil)

    2012-06-15

    Quantitative computed tomography was used to determine the radiodensity of bony plates. The CT scans provided information regarding radiodensity of bony plates and allowed to verify the uniformity of bone mineral density in their scope. The proposed methodology should be considered as another tool for determining the resistance of these biomaterials. (author)

  9. A systematic structural study of halogen bonding versus hydrogen bonding within competitive supramolecular systems

    Directory of Open Access Journals (Sweden)

    Christer B. Aakeröy

    2015-09-01

    Full Text Available As halogen bonds gain prevalence in supramolecular synthesis and materials chemistry, it has become necessary to examine more closely how such interactions compete with or complement hydrogen bonds whenever both are present within the same system. As hydrogen and halogen bonds have several fundamental features in common, it is often difficult to predict which will be the primary interaction in a supramolecular system, especially as they have comparable strength and geometric requirements. To address this challenge, a series of molecules containing both hydrogen- and halogen-bond donors were co-crystallized with various monotopic, ditopic symmetric and ditopic asymmetric acceptor molecules. The outcome of each reaction was examined using IR spectroscopy and, whenever possible, single-crystal X-ray diffraction. 24 crystal structures were obtained and subsequently analyzed, and the synthon preferences of the competing hydrogen- and halogen-bond donors were rationalized against a background of calculated molecular electrostatic potential values. It has been shown that readily accessible electrostatic potentials can offer useful practical guidelines for predicting the most likely primary synthons in these co-crystals as long as the potential differences are weighted appropriately.

  10. Role of dispersion corrected hybrid GGA class in accurately calculating the bond dissociation energy of carbon halogen bond: A benchmark study

    Science.gov (United States)

    Kosar, Naveen; Mahmood, Tariq; Ayub, Khurshid

    2017-12-01

    Benchmark study has been carried out to find a cost effective and accurate method for bond dissociation energy (BDE) of carbon halogen (Csbnd X) bond. BDE of C-X bond plays a vital role in chemical reactions, particularly for kinetic barrier and thermochemistry etc. The compounds (1-16, Fig. 1) with Csbnd X bond used for current benchmark study are important reactants in organic, inorganic and bioorganic chemistry. Experimental data of Csbnd X bond dissociation energy is compared with theoretical results. The statistical analysis tools such as root mean square deviation (RMSD), standard deviation (SD), Pearson's correlation (R) and mean absolute error (MAE) are used for comparison. Overall, thirty-one density functionals from eight different classes of density functional theory (DFT) along with Pople and Dunning basis sets are evaluated. Among different classes of DFT, the dispersion corrected range separated hybrid GGA class along with 6-31G(d), 6-311G(d), aug-cc-pVDZ and aug-cc-pVTZ basis sets performed best for bond dissociation energy calculation of C-X bond. ωB97XD show the best performance with less deviations (RMSD, SD), mean absolute error (MAE) and a significant Pearson's correlation (R) when compared to experimental data. ωB97XD along with Pople basis set 6-311g(d) has RMSD, SD, R and MAE of 3.14 kcal mol-1, 3.05 kcal mol-1, 0.97 and -1.07 kcal mol-1, respectively.

  11. Bony orbital distances among the Filipino population.

    Science.gov (United States)

    Barone, Constance M; Jimenez, David F; Laskey, Antoinette; Alcantara, Briccio G; Braddock, Stephen R

    2002-03-01

    Six hundred and seventy seven radiographs were selected from the logs of films taken in a major hospital in Metro Manila, Philippines over the course of the previous year. Two hundred and eighty-eight female and 389 male, healthy Filipinos between the ages of birth and twenty years were selected based on the availability of a modified Waters' projection and lateral skull film taken at the same time. Measurements for the lateral orbital wall were made at the site of the suture on the medial surface of the zygomatic bone. The medial orbital wall measurement was the distance between the dacrya using a correction factor formula of CF = D-d/D where D is the target film distance and d is the object film distance (1). The actual bony measurements were calculated. The data was gathered and plotted according to sex and in age in years. Graphs were generated using SAS over a graph software. Lines were smooth using cubic spline technique developed by Reinsch with the smoothest value of 75 (2). The mean plus two, four, and six standard deviations were included in each of the curves.

  12. Maternal bonding styles in smokers and non-smokers: a comparative study

    OpenAIRE

    Csala, Iren; Elemery, Monika; Martinovszky, Fruzsina; Dome, Peter; Dome, Balazs; Faludi, Gabor; Sandor, Imola; Gyorffy, Zsuzsa; Birkas, Emma; Lazary, Judit

    2016-01-01

    Background Parental bonding has been implicated in smoking behavior, and the quality of maternal bonding (MB) has been associated with poor mental health and substance use. However, little is known about the association of MB and the smoking of the offspring. Methods In our study, 129 smokers and 610 non-smoker medical students completed the parental bonding instrument, which measures MB along two dimensions: care and overprotection. Four categories can be created by high and low scores on ca...

  13. A Computational and Theoretical Study of Conductance in Hydrogen-bonded Molecular Junctions

    Science.gov (United States)

    Wimmer, Michael

    This thesis is devoted to the theoretical and computational study of electron transport in molecular junctions where one or more hydrogen bonds are involved in the process. While electron transport through covalent bonds has been extensively studied, in recent work the focus has been shifted towards hydrogen-bonded systems due to their ubiquitous presence in biological systems and their potential in forming nano-junctions between molecular electronic devices and biological systems. This analysis allows us to significantly expand our comprehension of the experimentally observed result that the inclusion of hydrogen bonding in a molecular junction significantly impacts its transport properties, a fact that has important implications for our understanding of transport through DNA, and nano-biological interfaces in general. In part of this work I have explored the implications of quasiresonant transport in short chains of weakly-bonded molecular junctions involving hydrogen bonds. I used theoretical and computational analysis to interpret recent experiments and explain the role of Fano resonances in the transmission properties of the junction. In a different direction, I have undertaken the study of the transversal conduction through nucleotide chains that involve a variable number of different hydrogen bonds, e.g. NH˙˙˙O, OH˙˙˙O, and NH˙˙˙N, which are the three most prevalent hydrogen bonds in biological systems and organic electronics. My effort here has focused on the analysis of electronic descriptors that allow a simplified conceptual and computational understanding of transport properties. Specifically, I have expanded our previous work where the molecular polarizability was used as a conductance descriptor to include the possibility of atomic and bond partitions of the molecular polarizability. This is important because it affords an alternative molecular description of conductance that is not based on the conventional view of molecular orbitals as

  14. Parental Bonding

    Directory of Open Access Journals (Sweden)

    T. Paul de Cock

    2014-08-01

    Full Text Available Estimating the early parent–child bonding relationship can be valuable in research and practice. Retrospective dimensional measures of parental bonding provide a means for assessing the experience of the early parent–child relationship. However, combinations of dimensional scores may provide information that is not readily captured with a dimensional approach. This study was designed to assess the presence of homogeneous groups in the population with similar profiles on parental bonding dimensions. Using a short version of the Parental Bonding Instrument (PBI, three parental bonding dimensions (care, authoritarianism, and overprotection were used to assess the presence of unobserved groups in the population using latent profile analysis. The class solutions were regressed on 23 covariates (demographics, parental psychopathology, loss events, and childhood contextual factors to assess the validity of the class solution. The results indicated four distinct profiles of parental bonding for fathers as well as mothers. Parental bonding profiles were significantly associated with a broad range of covariates. This person-centered approach to parental bonding has broad utility in future research which takes into account the effect of parent–child bonding, especially with regard to “affectionless control” style parenting.

  15. Allergy to fish collagen: Thermostability of collagen and IgE reactivity of patients' sera with extracts of 11 species of bony and cartilaginous fish.

    Science.gov (United States)

    Kobayashi, Yukihiro; Kuriyama, Takuma; Nakagawara, Ryoko; Aihara, Michiko; Hamada-Sato, Naoko

    2016-10-01

    Parvalbumin was identified as a major fish allergen, and has been well investigated. Collagen was identified as a second allergen; however, its allergenic properties remain uncharacterized. Although fish is an important staple in coastal countries, its thermostability is unknown. Therefore, we aimed to determine the thermostability of fish collagen as an allergen. Meat of seven bony and four cartilaginous fishes was heated at various temperatures and times, and extracts were analyzed using SDS-PAGE, IgE-ELISA, and SPTs. Collagen was dissolved from heated meat of Pacific mackerel into a crude extract. Collagen in the extracts was degraded at a high heating load-140 °C (10 min) or 100 °C (320 min). However, ELISA revealed the IgE reactivities of patients' sera with the extracts were unchanged even after heating the samples. Patients strongly reacted to extract proteins of other bony fish, which were detected by patients' IgE even after heating at 100 °C (320 min). In contrast, reactivities of the extracts of cartilaginous fish were lower than those of bony fish. SPTs in one patient revealed that all bony and cartilaginous fish extracts prepared from heated meat elicited allergic reactions. The IgE reactivity of patients' sera to fish collagen in extracts was retained even when fish meat was treated by a high heating load. As for the fish collagen, the IgE reactivities to cartilaginous fish were lower than that to bony fish. Reducing IgE reactivity to fish meat using heat is difficult, and other modalities will be required to produce hypoallergenic fish meat. Copyright © 2016 Japanese Society of Allergology. Production and hosting by Elsevier B.V. All rights reserved.

  16. First-principle study on bonding mechanism of ZnO by LDA+U method

    International Nuclear Information System (INIS)

    Zhou, G.C.; Sun, L.Z.; Zhong, X.L.; Chen Xiaoshuang; Wei Lu; Wang, J.B.

    2007-01-01

    The electronic structure and the bonding mechanism of ZnO have been studied by using the Full-Potential Linear Augmented Plane Wave (FP-LAPW) method within the density-functional theory (DFT) based on LDA+U exchange correlation potential. The valence and the bonding charge density are calculated and compared with those derived from LDA and GGA to describe the bonding mechanism. The charge transfer along with the bonding process is analyzed by using the theory of Atoms in Molecules (AIM). The bonding, the topological characteristics and the p-d coupling effects on the bonding mechanism of ZnO are shown quantitatively with the critical points (CPs) along the bonding trajectory and the charge in the atomic basins. Meanwhile, the bonding characteristics for wurtzite, zinc blende and rocksalt phase of ZnO are discussed systematically in the present paper

  17. Is radiographic measurement of bony landmarks reliable for lateral meniscal sizing?

    Science.gov (United States)

    Yoon, Jung-Ro; Kim, Taik-Seon; Lim, Hong-Chul; Lim, Hyung-Tae; Yang, Jae-Hyuk

    2011-03-01

    The accuracy of meniscal measurement methods is still in debate. The authors' protocol for radiologic measurements will provide reproducible bony landmarks, and this measurement method of the lateral tibial plateau will correlate with the actual anatomic value. Controlled laboratory study. Twenty-five samples of fresh lateral meniscus with attached proximal tibia were obtained during total knee arthroplasty. Each sample was obtained without damage to the meniscus and bony attachment sites. The inclusion criterion was mild to moderate osteoarthritis in patients with mechanical axis deviation of less than 15°. Knees with lateral compartment osteoarthritic change or injured or degenerated menisci were excluded. For the lateral tibial plateau length measurements, the radiographic beam was angled 10° caudally at neutral rotation, which allowed differentiation of the lateral plateau cortical margins from the medial plateau. The transition points were identified and used for length measurement. The values of length were then compared with the conventional Pollard method and the anatomic values. The width measurement was done according to Pollard's protocol. For each knee, the percentage deviation from the anatomic dimension was recorded. Intraobserver error and interobserver error were calculated. The deviation of the authors' radiographic length measurements from anatomic dimensions was 1.4 ± 1.1 mm. The deviation of Pollard's radiographic length measurements was 4.1 ± 2.0 mm. With respect to accuracy-which represents the frequency of measurements that fall within 10% of measurements-the accuracy of authors' length was 98%, whereas for Pollard's method it was 40%. There was a good correlation between anatomic meniscal dimensions and each radiologic plateau dimensions for lateral meniscal width (R(2) = .790) and the authors' lateral meniscal length (R(2) = .823) and fair correlation for Pollard's lateral meniscal length (R(2) = .660). The reliability of each

  18. Picosecond ultrasonics study of the modification of interfacial bonding by ion implantation

    International Nuclear Information System (INIS)

    Tas, G.; Loomis, J.J.; Maris, H.J.; Bailes, A.A. III; Seiberling, L.E.

    1998-01-01

    We report on experiments in which picosecond ultrasonic techniques are used to investigate the modification of interfacial bonding that results from ion implantation. The bonding is studied through measurements of the acoustic reflection coefficient at the interface. This method is nondestructive and can be used to create a map of the variation of the bonding over the area of the interface. copyright 1998 American Institute of Physics

  19. Value of diffusion weighted MRI in differentiating benign from malignant bony tumors and tumor like lesions

    Directory of Open Access Journals (Sweden)

    Samir Zaki Kotb

    2014-06-01

    Conclusion: DWI has been proven to be highly useful in the differentiation of benign, malignant bone tumors and tumor like bony lesions. Measurement of ADC values improves the accuracy of the diagnosis of bone tumors and tumor like lesions. Moreover, measurement of ADC values can be used in the follow up of tumors and their response to therapy.

  20. Cryosolution infrared study of hydrogen bonded halothane acetylene complex

    Science.gov (United States)

    Melikova, S. M.; Rutkowski, K. S.; Rospenk, M.

    2018-05-01

    The interactions between halothane (2-bromo-2-chloro-1,1,1-trifluoroethane) and acetylene (C2H2) are studied by FTIR spectroscopy. Results obtained in liquid cryosolutions in Kr suggest weak complex formation stabilized by H - bond. The complexation enthalpy (∼11 kJ/mol) is evaluated in a series of temperature measurements (T ∼ 120-160 K) of integrated intensity of selected bands performed in liquefied Kr. The quantum chemical MP2/6-311++G(2d,2p) calculations predict four different structures of the complex. The most stable and populated (94% at T∼120 K) structure corresponds to the H - bond between H atom of halothane and pi-electron of triple bond between C atoms of acetylene. Wave numbers of vibrational bands of the most stable structure are calculated in anharmonic approximation implemented in Gaussian program.

  1. Studies of IBL wire bonds operation in a ATLAS-like magnetic field.

    CERN Document Server

    Alvarez Feito, D; Mandelli, B

    2015-01-01

    At the Large Hadron Collider (LHC) experiments, most of silicon detectors use wire bonds to connect front-end chips and sensors to circuit boards for the data and service trans- missions. These wire bonds are operated in strong magnetic field environments and if time varying currents pass through them with frequencies close to their mechanical resonance frequency, strong resonant oscillations may occur. Under certain conditions, this effect can lead to fatigue stress and eventually breakage of wire bonds. During the first LHC Long Shutdown, the ATLAS Pixel Detector has been upgraded with the addition of a fourth innermost layer, the Insertable B-Layer (IBL), which has more than 50000 wire bonds operated in the ATLAS 2 T magnetic field. The results of systematic studies of operating wire bonds under IBL-like conditions are presented. Two different solutions have been investigated to minimize the oscillation amplitude of wire bonds.

  2. Experimental Study on Steel to FRP Bonded Lap Joints in Marine Applications

    Directory of Open Access Journals (Sweden)

    Çiçek Özes

    2015-01-01

    Full Text Available Steel structures coated with fiber-reinforced polymer (FRP composites have gained wide acceptance in marine industry due to their high strength-to-weight ratio, good protection from environmental degradation, and impact loads. In this study, adhesive bonding performance of single-lap bonded joints composed of steel coated with FRP has been investigated experimentally for three different surface roughness and two epoxy types. Single-lap bonded joints have been tested under tensile loading. The adhesive bonding performance has been evaluated by calculating the strain energy values. The results reveal that the surface roughness of steel has a significant effect on the bonding performance of steel to FRP combinations and the performance of the resin can be improved by using the primer in an economical way.

  3. Porous surface modified bioactive bone cement for enhanced bone bonding.

    Directory of Open Access Journals (Sweden)

    Qiang He

    Full Text Available Polymethylmethacrylate bone cement cannot provide an adhesive chemical bonding to form a stable cement-bone interface. Bioactive bone cements show bone bonding ability, but their clinical application is limited because bone resorption is observed after implantation. Porous polymethylmethacrylate can be achieved with the addition of carboxymethylcellulose, alginate and gelatin microparticles to promote bone ingrowth, but the mechanical properties are too low to be used in orthopedic applications. Bone ingrowth into cement could decrease the possibility of bone resorption and promote the formation of a stable interface. However, scarce literature is reported on bioactive bone cements that allow bone ingrowth. In this paper, we reported a porous surface modified bioactive bone cement with desired mechanical properties, which could allow for bone ingrowth.The porous surface modified bioactive bone cement was evaluated to determine its handling characteristics, mechanical properties and behavior in a simulated body fluid. The in vitro cellular responses of the samples were also investigated in terms of cell attachment, proliferation, and osteoblastic differentiation. Furthermore, bone ingrowth was examined in a rabbit femoral condyle defect model by using micro-CT imaging and histological analysis. The strength of the implant-bone interface was also investigated by push-out tests.The modified bone cement with a low content of bioactive fillers resulted in proper handling characteristics and adequate mechanical properties, but slightly affected its bioactivity. Moreover, the degree of attachment, proliferation and osteogenic differentiation of preosteoblast cells was also increased. The results of the push-out test revealed that higher interfacial bonding strength was achieved with the modified bone cement because of the formation of the apatite layer and the osseointegration after implantation in the bony defect.Our findings suggested a new bioactive

  4. The Study on bonding test of Inconel 617 Heat Exchanger by Measuring Properties

    International Nuclear Information System (INIS)

    Cho, Il Hwan; Song, Chan Ho; Yoon, Seok Ho; Park, Sang Jin

    2014-01-01

    Basic materials are not melted and bonded through the diffusion of atoms. It is different from welding in a view point of not melting and additional bonding insertion materials are not used which is different from the method in brazing. This bonding method is favor for ultra high temperature and pressure condition, and the bonding part becomes almost same structure and property with high heat resistance and strength when it is compared with brazing method. But the process time is long and the cost is high. The quantitative analysis in bonding surface has not been suggested yet. In this paper, the bonding performance for diffusion bonded heat exchanger is examined and analyzed where its material is Inconel 617. thermal and mechanical properties such as thermal diffusivity and tensile strength are measured and compared for different bonding conditions. In this study, the bonding performance for heat exchanger using Inconel 617 is analyzed by measuring thermal and mechanical properties such as thermal diffusivity and tensile strength. The following results are obtained. From measuring thermal diffusivity, it is found that the difference between the diffusion bonded plates and bond failed plates is within 3%. The tensile strength in diffusion bonding is about 25% lower than that of original plate at 1150 .deg. C, but it is over 600 MPa. As bonding temperature increases, the size of grain boundary decreases From these results, the possibility for Inconel 617 heat exchanger under the high temperature and pressure through diffusion bonding process could be obtained and it is thought to be applied for many industrial equipment

  5. The Study on bonding test of Inconel 617 Heat Exchanger by Measuring Properties

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Il Hwan; Song, Chan Ho; Yoon, Seok Ho; Park, Sang Jin [Korea Institute of Machinery and Materials, Daejeon (Korea, Republic of)

    2014-05-15

    Basic materials are not melted and bonded through the diffusion of atoms. It is different from welding in a view point of not melting and additional bonding insertion materials are not used which is different from the method in brazing. This bonding method is favor for ultra high temperature and pressure condition, and the bonding part becomes almost same structure and property with high heat resistance and strength when it is compared with brazing method. But the process time is long and the cost is high. The quantitative analysis in bonding surface has not been suggested yet. In this paper, the bonding performance for diffusion bonded heat exchanger is examined and analyzed where its material is Inconel 617. thermal and mechanical properties such as thermal diffusivity and tensile strength are measured and compared for different bonding conditions. In this study, the bonding performance for heat exchanger using Inconel 617 is analyzed by measuring thermal and mechanical properties such as thermal diffusivity and tensile strength. The following results are obtained. From measuring thermal diffusivity, it is found that the difference between the diffusion bonded plates and bond failed plates is within 3%. The tensile strength in diffusion bonding is about 25% lower than that of original plate at 1150 .deg. C, but it is over 600 MPa. As bonding temperature increases, the size of grain boundary decreases From these results, the possibility for Inconel 617 heat exchanger under the high temperature and pressure through diffusion bonding process could be obtained and it is thought to be applied for many industrial equipment.

  6. Factors Affecting the Shear Bond Strength of Orthodontic Brackets - a Review of In Vitro Studies.

    Science.gov (United States)

    Bakhadher, Waleed; Halawany, Hassan; Talic, Nabeel; Abraham, Nimmi; Jacob, Vimal

    2015-01-01

    The adhesive material used to bond orthodontic brackets to teeth should neither fail during the treatment period, resulting in treatment delays, untoward expenses or patient inconvenience nor should it damage the enamel on debonding at the end of the treatment. Although the effectiveness of a bonding system and any unfavorable effects on the enamel may be studied by conducting in-vivo studies, it is nearly impossible to independently analyze different variables that influence a specific bonding system in the oral environment. In-vitro studies, on the other hand, may utilize more standardized protocols for testing different bonding systems and materials available. Thus, the present review focused attention on in-vitro studies and made an attempt to discuss material-related, teeth-related (fluorotic vs non-fluorotic teeth) and other miscellaneous factors that influences the shear bond strength of orthodontic brackets. Within the limitations of this review, using conventional acid-etch technique, ceramic brackets and bonding to non-fluorotic teeth was reported to have a positive influence on the shear bond strength of orthodontic brackets, but higher shear bond strength found on using ceramic brackets can be dangerous for the enamel.

  7. Pressure bonding molybdenum alloy (TZM) to reaction-bonded silicon nitride

    International Nuclear Information System (INIS)

    Huffsmith, S.A.; Landingham, R.L.

    1978-01-01

    Topping cycles could boost the energy efficiencies of a variety of systems by using what is now waste heat. One such topping cycle uses a ceramic helical expander and would require that a reaction-bonded silicon nitride (RBSN) rotor be bonded to a shaft of TZM (Mo-0.5 wt % Ti-0.08 wt % Zr). Coupon studies show that TZM can be bonded to RBSN at 1300 0 C and 69 MPa if there is an interlayer of MoSi 2 . A layer of finely ground (10 μm) MoSi 2 facilitates bond formation and provides a thicker bond interface. The hardness and grain structure of the TZM and RBSN were not affected by the temperature and pressure required to bond the coupons

  8. Modeling of the bony pelvis from MRI using a multi-atlas AE-SDM for registration and tracking in image-guided robotic prostatectomy.

    Science.gov (United States)

    Gao, Qinquan; Chang, Ping-Lin; Rueckert, Daniel; Ali, S Mohammed; Cohen, Daniel; Pratt, Philip; Mayer, Erik; Yang, Guang-Zhong; Darzi, Ara; Edwards, Philip Eddie

    2013-03-01

    A fundamental challenge in the development of image-guided surgical systems is alignment of the preoperative model to the operative view of the patient. This is achieved by finding corresponding structures in the preoperative scans and on the live surgical scene. In robot-assisted laparoscopic prostatectomy (RALP), the most readily visible structure is the bone of the pelvic rim. Magnetic resonance imaging (MRI) is the modality of choice for prostate cancer detection and staging, but extraction of bone from MRI is difficult and very time consuming to achieve manually. We present a robust and fully automated multi-atlas pipeline for bony pelvis segmentation from MRI, using a MRI appearance embedding statistical deformation model (AE-SDM). The statistical deformation model is built using the node positions of deformations obtained from hierarchical registrations of full pelvis CT images. For datasets with corresponding CT and MRI images, we can transform the MRI into CT SDM space. MRI appearance can then be used to improve the combined MRI/CT atlas to MRI registration using SDM constraints. We can use this model to segment the bony pelvis in a new MRI image where there is no CT available. A multi-atlas segmentation algorithm is introduced which incorporates MRI AE-SDMs guidance. We evaluated the method on 19 subjects with corresponding MRI and manually segmented CT datasets by performing a leave-one-out study. Several metrics are used to quantify the overlap between the automatic and manual segmentations. Compared to the manual gold standard segmentations, our robust segmentation method produced an average surface distance 1.24±0.27mm, which outperforms state-of-the-art algorithms for MRI bony pelvis segmentation. We also show that the resulting surface can be tracked in the endoscopic view in near real time using dense visual tracking methods. Results are presented on a simulation and a real clinical RALP case. Tracking is accurate to 0.13mm over 700 frames

  9. Bond Feasibility Study. Project Identification Committee Report.

    Science.gov (United States)

    Wichita Public Schools, KS.

    A committee, appointed by the Board of Education, was requested to make a comprehensive study of the school building needs of Unified School District No. 259. In an attempt to determine the feasibility of a general bond election to upgrade the public schools, the specific charge to the committee was to evaluate the needs for physical plant…

  10. Mechanical and Non-Destructive Study of CFRP Adhesive Bonds Subjected to Pre-Bond Thermal Treatment and De-Icing Fluid Contamination

    Directory of Open Access Journals (Sweden)

    Paweł H. Malinowski

    2018-04-01

    Full Text Available Composite materials are commonly used in many branches of industry. One of the effective methods to join the carbon fibre reinforced polymer (CFRP parts includes the use of adhesives. There is a search on effective methods for quality assurance of bonded parts. In the research here reported the influence of surface pre-bond modification on the adhesive bonds of CFRP plates has been analyzed. Adherends surface modifications, to include defects affecting the bonding quality, were obtained through surface thermal treatment, surface contamination with de-icing fluid and a combination of both the previously described treatments. Characterization of bonded joints was performed by means of mechanical testing, ultrasounds and electromechanical impedance (EMI measurements. The study here proposed has also the aim to evaluate the ability of different destructive and non-destructive techniques to assess the quality of the bonds. While mechanical tests were strongly affected by the surface modifications, results obtained ultrasound and EMI test have demonstrate only a limited ability of these techniques to differentiate between the different samples. In fact, ultrasounds did not show any changes in the bondline, due to pre-bond modifications. However, this technique was able to detect delamination in CFRP for one of the samples thermally treated at 280 °C. Electromechanical impedance (EMI measurements showed similar behavior as mechanical tests for samples thermally treated at 260 °C and 280 °C, and for the sample whose surface modification was made with a combination of thermally and de-icing fluid treatments.

  11. Energetics of hydrogen bonding in proteins: a model compound study.

    OpenAIRE

    Habermann, S. M.; Murphy, K. P.

    1996-01-01

    Differences in the energetics of amide-amide and amide-hydroxyl hydrogen bonds in proteins have been explored from the effect of hydroxyl groups on the structure and dissolution energetics of a series of crystalline cyclic dipeptides. The calorimetrically determined energetics are interpreted in light of the crystal structures of the studied compounds. Our results indicate that the amide-amide and amide-hydroxyl hydrogen bonds both provide considerable enthalpic stability, but that the amide-...

  12. Experimental Study on Fatigue Behaviour of BFRP-Concrete Bond Interfaces under Bending Load

    Directory of Open Access Journals (Sweden)

    Jianhe Xie

    2018-01-01

    Full Text Available Basalt fiber reinforced polymer (BFRP composites are increasingly being used to retrofit concrete structures by external bonding. For such strengthened members, the BFRP-concrete interface plays the crucial role of transferring stresses. This study aims to investigate the fatigue behaviour of the interface under bending load. A series of tests were conducted on BFRP-concrete bonded joint, including static, fatigue, and postfatigue loading. The fatigue failure modes, the development of deflection, the evolution of BFRP strains, and the propagation of interfacial cracks were analysed. In addition, the debonding-induced fatigue life of BFRP-concrete bonded joints was studied. Finally, a new model of fatigue life was proposed by defining the effective fatigue bond stress. The results showed that the fatigue experience has a significant effect on the BFRP strength especially near the root of concrete transverse crack and on the bond performance of the adhesive near the interface crack tip. There are two main fatigue failure modes: BFRP rupture and BFRP debonding. The fatigue damage development of the bond interface has three stages: rapid, stable, and unstable growth. The proposed model for the debonding-induced fatigue life is more conservative for the BFRP-concrete bonded joints under pure shear load than for those under bending load.

  13. Bond Ratings dan Antesedennya: Studi Empiris di Bursa Efek Indonesia

    Directory of Open Access Journals (Sweden)

    Wendy Wendy

    2017-01-01

    Full Text Available This paper provides the empirical evidence of corporate growth, maturity, and operating cash flows on the bond ratings. It was conducted on 34 bonds issued by the 16 non-financial companies on the Indonesia Stock Exchange (IDX which also issued bonds, registered in the Indonesia Bond Market Directory, and rated by PEFINDO during 2012 - 2014. The hypotheses were tested using the logistic regression analysis. The result shows that corporate growth has significant effect on the bond ratings, while maturity and operating cash flow have no significant effect. Another finding shows that the firm size can also affect the bond ratings.

  14. On-line image guidance for frameless stereotactic radiotherapy of lung malignancies by cone beam CT: Comparison between target localization and alignment on bony anatomy

    International Nuclear Information System (INIS)

    Masi, Laura; Casamassima, Franco; Menichelli, Claudia; Pasciuti, Katia; Doro, Raffaela; Polli, Caterina; D'imporzano, Elena; Bonucci, Ivano

    2008-01-01

    Introduction. Free-breathing stereotactic radiotherapy for lung malignancies requires reliable prediction of respiratory motion and accurate target localization. A protocol was adopted for reproducibility and reduction of respiratory motion and for target localization by CBCT image guidance. Tumor respiratory displacements and tumor positioning errors relative to bony anatomy alignment are analyzed. Materials and method. Image guided SRT was performed for 99 lung malignancies. Two groups of patients were considered: group A did not perform any breathing control; group B controlled visually their respiratory cycle and volumes on an Active Breathing Coordinator (ABC) monitor during the acquisition of simulation CT and CBCT, and treatment delivery. GTV on end inhale and exhale CT data sets were fused in an ITV and the extent of tumor motion evaluated between these 2 phases. A pre-treatment CBCT was acquired and aligned to the reference CT using bony anatomy; for tumor positioning the ITV contour on the reference CT was matched to the visible tumor on CBCT. Interobserver variability of tumor positioning was evaluated. ITV and CBCT tumor dimensions were compared. Results. 3D tumor breathing displacement (mean±SD) was significantly higher for group A (14.7±9.9 mm) than for group B (4.7±3.1 mm). The detected differences between tumor and bony structure alignment below 3 mm were 68% for group B and 45% for group A, reaching statistical significance. Interobserver variability was 1.7±1.1 mm (mean±SD). Dimensions of tumor image on CBCT were consistent with ITV dimensions for group B (max difference 14%). Conclusions. The adopted protocol seems effective in reducing respiratory internal movements and margin. Tumor positioning errors relative to bony anatomy are also reduced. However bony anatomy as a surrogate of the target may still lead to some relevant positioning errors. Target visualization on CBCT is essential for an accurate localization in lung SRT

  15. TDDFT study on intramolecular hydrogen bond of photoexcited methyl salicylate.

    Science.gov (United States)

    Qu, Peng; Tian, Dongxu

    2014-01-01

    The equilibrium geometries, IR-spectra and transition mechanism of intramolecular hydrogen-bonded methyl salicylate in excited state were studied using DFT and TDDFT with 6-31++G (d, p) basis set. The length of hydrogen bond OH⋯OC is decreased from 1.73 Å in the ground state to 1.41 and 1.69 Å in the excited S1 and S3 states. The increase of bond length for HO and CO group also indicates that in excited state the hydrogen bond OH⋯OC is strengthened. IR spectra show HO and CO stretching bands are strongly redshifted by 1387 and 67 cm(-1) in the excited S1 and S3 states comparing to the ground state. The excitation energy and the absorption spectrum show the S3 state is the main excited state of the low-lying excited states. By analyzing the frontier molecular orbitals, the transition from the ground state to the excited S1 and S3 states was predicted to be the π→π∗ mode. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Daily online bony correction is required for prostate patients without fiducial markers or soft-tissue imaging.

    Science.gov (United States)

    Johnston, M L; Vial, P; Wiltshire, K L; Bell, L J; Blome, S; Kerestes, Z; Morgan, G W; O'Driscoll, D; Shakespeare, T P; Eade, T N

    2011-09-01

    To compare online position verification strategies with offline correction protocols for patients undergoing definitive prostate radiotherapy. We analysed 50 patients with implanted fiducial markers undergoing curative prostate radiation treatment, all of whom underwent daily kilovoltage imaging using an on-board imager. For each treatment, patients were set-up initially with skin tattoos and in-room lasers. Orthogonal on-board imager images were acquired and the couch shift to match both bony anatomy and the fiducial markers recorded. The set-up error using skin tattoos and offline bone correction was compared with online bone correction. The fiducial markers were used as the reference. Data from 1923 fractions were analysed. The systematic error was ≤1 mm for all protocols. The average random error was 2-3mm for online bony correction and 3-5mm for skin tattoos or offline-bone. Online-bone showed a significant improvement compared with offline-bone in the number of patients with >5mm set-up errors for >10% (P20% (Pmarkers or daily soft-tissue imaging. Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  17. Reconstruction of bony facial contour deficiencies with polymethylmethacrylate implants: case report

    Directory of Open Access Journals (Sweden)

    Ruy C. C. Abdo Filho

    2011-08-01

    Full Text Available Facial trauma can be considered one of the most serious aggressions found in the medical centers due to the emotional consequences and the possibility of deformity. In craniofacial surgery, the use of autologous bone is still the first choice for reconstructing bony defects or irregularities. When there is a shortage of donor bone or a patient refuses an intracranial operation, alloplastic materials such as polymethylmethacrylate (PMMA can be used. The PMMA prosthesis can be pre-fabricated, bringing advantages such as reduction of surgical time, easy technical handling and good esthetic results. This paper describes the procedures for rehabilitating a patient with PMMA implants in the region of the face, recovering the facial contours and esthetics of the patient.

  18. Bony contact area and displacement of the temporomandibular joint after high-oblique and bilateral sagittal split osteotomy: a computer-simulated comparison.

    Science.gov (United States)

    Möhlhenrich, Stephan Christian; Kamal, Mohammad; Peters, Florian; Fritz, Ulrike; Hölzle, Frank; Modabber, Ali

    2016-04-01

    The most common way to move the mandible during orthognathic surgery is by bilateral sagittal split osteotomy (BSSO). The high-oblique sagittal split osteotomy (HSSO) is an alternative, although its use is limited by potential complications, mainly to do with the position of the condyle and reduced contact with bone. The aim of this study was to find out the optimal intercondylar distance and area of contact with the surface of the bone for mandibular advancement and setback in BSSO and HSSO. Data from computed tomographic (CT) images from 40 patients were loaded into special planning software, and virtual operations done for mandibular advancement and setback at 3, 5, 8, and 10mm using BSSO and HSSO, which resulted in 640 individual mandibular displacements. The resultant area of bony contact and intercondylar distance were calculated by the software. The mean (SD) areas of contact with the bony surface after 10mm advancement for HSSO and BSSO were 193.94 (63.76) mm(2) and 967.92 (229.21) mm(2), respectively, and after 10mm setback 202.64 (62.30) mm(2) and 1108.86 (247.38) mm(2). The mean corresponding intercondylar distance after maximum advancement were 86.76 (6.40) mm and 86.59 (6.24) mm, and after maximum setback 74.90 (5.73) mm and 73.06 (6.06) mm. There were significant differences between the two for the area of contact with the surface at each displacement distance (parea of bony contact can be expected at any displacement distance for BSSO, so the changes in intercondylar distance should not be considered when deciding which osteotomy to select. Copyright © 2015 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  19. Room temperature Cu-Cu direct bonding using surface activated bonding method

    International Nuclear Information System (INIS)

    Kim, T.H.; Howlader, M.M.R.; Itoh, T.; Suga, T.

    2003-01-01

    Thin copper (Cu) films of 80 nm thickness deposited on a diffusion barrier layered 8 in. silicon wafers were directly bonded at room temperature using the surface activated bonding method. A low energy Ar ion beam of 40-100 eV was used to activate the Cu surface prior to bonding. Contacting two surface-activated wafers enables successful Cu-Cu direct bonding. The bonding process was carried out under an ultrahigh vacuum condition. No thermal annealing was required to increase the bonding strength since the bonded interface was strong enough at room temperature. The chemical constitution of the Cu surface was examined by Auger electron spectroscope. It was observed that carbon-based contaminations and native oxides on copper surface were effectively removed by Ar ion beam irradiation for 60 s without any wet cleaning processes. An atomic force microscope study shows that the Ar ion beam process causes no surface roughness degradation. Tensile test results show that high bonding strength equivalent to bulk material is achieved at room temperature. The cross-sectional transmission electron microscope observations reveal the presence of void-free bonding interface without intermediate layer at the bonded Cu surfaces

  20. Human bony labyrinth is an indicator of population history and dispersal from Africa.

    Science.gov (United States)

    Ponce de León, Marcia S; Koesbardiati, Toetik; Weissmann, John David; Milella, Marco; Reyna-Blanco, Carlos S; Suwa, Gen; Kondo, Osamu; Malaspinas, Anna-Sapfo; White, Tim D; Zollikofer, Christoph P E

    2018-04-17

    The dispersal of modern humans from Africa is now well documented with genetic data that track population history, as well as gene flow between populations. Phenetic skeletal data, such as cranial and pelvic morphologies, also exhibit a dispersal-from-Africa signal, which, however, tends to be blurred by the effects of local adaptation and in vivo phenotypic plasticity, and that is often deteriorated by postmortem damage to skeletal remains. These complexities raise the question of which skeletal structures most effectively track neutral population history. The cavity system of the inner ear (the so-called bony labyrinth) is a good candidate structure for such analyses. It is already fully formed by birth, which minimizes postnatal phenotypic plasticity, and it is generally well preserved in archaeological samples. Here we use morphometric data of the bony labyrinth to show that it is a surprisingly good marker of the global dispersal of modern humans from Africa. Labyrinthine morphology tracks genetic distances and geography in accordance with an isolation-by-distance model with dispersal from Africa. Our data further indicate that the neutral-like pattern of variation is compatible with stabilizing selection on labyrinth morphology. Given the increasingly important role of the petrous bone for ancient DNA recovery from archaeological specimens, we encourage researchers to acquire 3D morphological data of the inner ear structures before any invasive sampling. Such data will constitute an important archive of phenotypic variation in present and past populations, and will permit individual-based genotype-phenotype comparisons. Copyright © 2018 the Author(s). Published by PNAS.

  1. Structure phenomena in the bond zone of explosively bonded plates

    International Nuclear Information System (INIS)

    Livne, Z.

    1979-12-01

    In the bond areas of couples of explosively bonded plates, there are often zones, generally designated as ''molten pockets'', which have undergone melting and solidification. The object of the present study was to investigate molten pockets, which have a decisive effect on bond quality. The experimental samples for the study were chosen in consideration of the mutual behaviour of the plates constituting the couples, according to their equilibrium phase diagrams. To facilitate the investigation, large plates were bonded under conditions that enabled to to obtain wavy bond zones that included relatively large molten pockets. To clarify the complex nature of molten pockets and their surroundings, a wide variety of methods were employed. It was found that the shape and composition of molten pockets largely depend upon the mechanism of formation of both the bond wave and the molten pockets. It was also found that the composition of molten pockets is not homogeneous, which is manifest in the modification of the composition of the pockets, the solidification morphology, the phases, which have been identified by X-ray diffraction, and the bond strenght and hardness. Moreover, the different solidification morphologies revealed by metallography were found to depend upon the types of plates bonded, the bonding conditions and the location of pockets in the wavy interface. For molten pockets, cooling rates of 10 4 to 10 5 (degC/sec) have been deduced from interdendritic spacing, and found to be in good agreement with calculations after a mathematical model. It seems that the fast cooling rates and the steep temperature gradients are at the origin of the particular solidification phenomena observed in molten pockets

  2. Crack propagation studies and bond coat properties in thermal

    Indian Academy of Sciences (India)

    High threshold load at the interface between the ceramic layer and the bond coat was required to propagate the crack further into the bond coat. Once the threshold load was surpassed the crack propagated into the brittle bond coat without an appreciable increase in the load. At temperatures of 800°C the crack propagated ...

  3. A Study of Bond of Structural Timber and Carbon Fiber Reinforced Polymer Plate

    Directory of Open Access Journals (Sweden)

    Yongtaeg LEE

    2015-11-01

    Full Text Available The increase of well-being culture of problem related to environmental depletion of resource is not the growing interest in timber the natural material of construction markets. Also, the perception for historic preservation has been increased in respond to heightened interest. However, it is fairly difficult for architectural properties to maintain their durability because it was made by timber construction. Preventing traditional structure from damage and structural performance reduction is paramount in maintenance problem. A number of studies of reinforced method have been conducted in order to solve such a problem. In this paper, external bonded reinforcement and near-surface mounted was used as a way to reinforce timber structure’s durability. Bond strength for specimens with different bond length was investigated. As a result showed, maximum bond strength in bond length 300 mm from all method, was found to be not increased of bond strength over the certain bond length.DOI: http://dx.doi.org/10.5755/j01.ms.21.4.9702

  4. Neutron Crystallography for the Study of Hydrogen Bonds in Macromolecules

    Directory of Open Access Journals (Sweden)

    Esko Oksanen

    2017-04-01

    Full Text Available Abstract: The hydrogen bond (H bond is one of the most important interactions that form the foundation of secondary and tertiary protein structure. Beyond holding protein structures together, H bonds are also intimately involved in solvent coordination, ligand binding, and enzyme catalysis. The H bond by definition involves the light atom, H, and it is very difficult to study directly, especially with X-ray crystallographic techniques, due to the poor scattering power of H atoms. Neutron protein crystallography provides a powerful, complementary tool that can give unambiguous information to structural biologists on solvent organization and coordination, the electrostatics of ligand binding, the protonation states of amino acid side chains and catalytic water species. The method is complementary to X-ray crystallography and the dynamic data obtainable with NMR spectroscopy. Also, as it gives explicit H atom positions, it can be very valuable to computational chemistry where exact knowledge of protonation and solvent orientation can make a large difference in modeling. This article gives general information about neutron crystallography and shows specific examples of how the method has contributed to structural biology, structure-based drug design; and the understanding of fundamental questions of reaction mechanisms.

  5. Conceptual design study of Cu bonded steam generator

    International Nuclear Information System (INIS)

    Chikazawa, Yoshitaka; Konomura, Mamoru

    2004-05-01

    In phase II of feasibility study of commercialized fast reactor cycle systems of JNC, we make a concept of a sodium cooled reactor without secondary sodium circuits. And a sodium cooled reactor with Cu bonded steam generators is one of promising concept. As the result of FY 2001 study, the construction cost of reactor cooling system with rectangular tube Cu bonded steam generators is 0.71 to 1.23 times as much as that of an ordinary sodium cooled reactor with secondary sodium circuits. In the FY 2003 study, plastic and creep analysis to evaluate life distortion are carried out and inelastic strains and creep fatigue damage are checked for full code compliance. The NNC's crack growth experiments show that there are few possibility to penetrate a crack from the steam tube side to the sodium tube side at the operating temperature. But penetration is observed in a four point bend test at the room temperature, because the notch opens widely in the bend test. In the FY 2004 study, a gas pressurized crack growth experiment is planed to confirm that there is no crack penetration in the condition of operating steam generators. (author)

  6. Chemical activation of molecules by metals: Experimental studies of electron distributions and bonding

    International Nuclear Information System (INIS)

    Lichtenberger, D.L.

    1991-10-01

    The formal relationship between measured molecular ionization energies and thermodynamic bond dissociation energies has been developed into a single equation which unifies the treatment of covalent bonds, ionic bonds, and partially ionic bonds. This relationship has been used to clarify the fundamental thermodynamic information relating to metal-hydrogen, metal-alkyl, and metal-metal bond energies. We have been able to obtain a direct observation and measurement of the stabilization energy provided by the agostic interaction of the C-H bond with the metal. The ionization energies have also been used to correlate the rates of carbonyl substitution reactions of (η 5 -C 5 H 4 X)Rh(CO) 2 complexes, and to reveal the electronic factors that control the stability of the transition state. The extent that the electronic features of these bonding interactions transfer to other chemical systems is being investigated in terms of the principle of additivity of ligand electronic effects. Specific examples under study include metal- phosphines, metal-halides, and metallocenes. Especially interesting has been the recent application of these techniques to the characterization of the soccer-ball shaped C 60 molecule, buckminsterfullerene, and its interaction with a metal surface. The high-resolution valence ionizations in the gas phase reveal the high symmetry of the molecule, and studies of thin films of C 60 reveal weak intermolecular interactions. Scanning tunneling and atomic force microscopy reveal the arrangement of spherical molecules on gold substrates, with significant delocalization of charge from the metal surface. 21 refs

  7. A Bony Landmark 'RAI Triangle' to Prevent 'Misplaced and Misdirected' Medial Cut in SSRO.

    Science.gov (United States)

    Rai, Kirthi Kumar; Arakeri, Gururaj; Khaji, Shahanavaj I

    2011-03-01

    'Rai triangle', a new anatomic landmark on the medial surface of the ramus of the mandible which when identified and taken into consideration, may have a definite advantage. This is especially in terms of performing the medial horizontal cut which is an important and integral part of the sagittal split ramus osteotomy so as to avoid a bad split. The objective of this article is to propose an easily identifiable bony land mark, which is closely related to lingula of mandible that may ease the procedure of osteotomy and avoid bad splits.

  8. The bony labyrinth of the middle Pleistocene Sima de los Huesos hominins (Sierra de Atapuerca, Spain).

    Science.gov (United States)

    Quam, Rolf; Lorenzo, Carlos; Martínez, Ignacio; Gracia-Téllez, Ana; Arsuaga, Juan Luis

    2016-01-01

    We performed 3D virtual reconstructions based on CT scans to study the bony labyrinth morphology in 14 individuals from the large middle Pleistocene hominin sample from the site of the Sima de los Huesos (SH) in the Sierra de Atapuerca in northern Spain. The Atapuerca (SH) hominins represent early members of the Neandertal clade and provide an opportunity to compare the data with the later in time Neandertals, as well as Pleistocene and recent humans more broadly. The Atapuerca (SH) hominins do not differ from the Neandertals in any of the variables related to the absolute and relative sizes and shape of the semicircular canals. Indeed, the entire Neandertal clade seems to be characterized by a derived pattern of canal proportions, including a relatively small posterior canal and a relatively large lateral canal. In contrast, one of the most distinctive features observed in Neandertals, the low placement of the posterior canal (i.e., high sagittal labyrinthine index), is generally not present in the Atapuerca (SH) hominins. This low placement is considered a derived feature in Neandertals and is correlated with a more vertical orientation of the ampullar line (LSCm  PPp), and third part of the facial canal (LSCm < FC3). Some variation is present within the Atapuerca (SH) sample, however, with a few individuals approaching the Neandertal condition more closely. In addition, the cochlear shape index in the Atapuerca (SH) hominins is low, indicating a reduction in the height of the cochlea. Although the phylogenetic polarity of this feature is less clear, the low shape index in the Atapuerca (SH) hominins may be a derived feature. Regardless, cochlear height subsequently increased in Neandertals. In contrast to previous suggestions, the expanded data in the present study indicate no difference across the genus Homo in the angle of inclination of the cochlear basal turn (COs < LSCm). Principal components analysis largely confirms these observations. While not

  9. Mechanism of bonding and debonding using surface activated bonding method with Si intermediate layer

    Science.gov (United States)

    Takeuchi, Kai; Fujino, Masahisa; Matsumoto, Yoshiie; Suga, Tadatomo

    2018-04-01

    Techniques of handling thin and fragile substrates in a high-temperature process are highly required for the fabrication of semiconductor devices including thin film transistors (TFTs). In our previous study, we proposed applying the surface activated bonding (SAB) method using Si intermediate layers to the bonding and debonding of glass substrates. The SAB method has successfully bonded glass substrates at room temperature, and the substrates have been debonded after heating at 450 °C, in which TFTs are fabricated on thin glass substrates for LC display devices. In this study, we conducted the bonding and debonding of Si and glass in order to understand the mechanism in the proposed process. Si substrates are also successfully bonded to glass substrates at room temperature and debonded after heating at 450 °C using the proposed bonding process. By the composition analysis of bonding interfaces, it is clarified that the absorbed water on the glass forms interfacial voids and cause the decrease in bond strength.

  10. Importance of bony analysis for interpreting ear CT scans: part three; ORL - tomodensitometrie de l'oreille. Interet de l'analyse osseuse dans l'interpretation des scanners de l'oreille (troisieme partie)

    Energy Technology Data Exchange (ETDEWEB)

    Serhal, M.; Dordea, M.; Cymbalista, M. [Hopital de Montfermeil, Service de Radiologie, 93 - Montfermeil (France); Halimi, P. [Hopital Europeen Georges-Pompidou, Service de Radiologie, 75 - Paris (France); Iffenecker, C. [Clinique Radiologique, 62 - Boulogne sur Mer (France); Bensimon, J.L

    2003-02-01

    The accurate description of bony changes in ear CT scans has a great diagnostic and therapeutic impact. The third part shows the way to analyze bone remodeling when CT scan is performed for tumors in the vicinity of the temporal bone, for intra temporal lesions of the facial nerve and for external auditory canal malformations. It demonstrates how bony analysis should be included in postoperative report of ear CT scan. The importance of bony signs in tumors and pseudo tumors of the inner ear are outlined. (authors)

  11. Recent Advances in Adhesive Bonding - The Role of Biomolecules, Nanocompounds, and Bonding Strategies in Enhancing Resin Bonding to Dental Substrates.

    Science.gov (United States)

    Münchow, Eliseu A; Bottino, Marco C

    2017-09-01

    To present an overview on the main agents (i.e., biomolecules and nanocompounds) and/or strategies currently available to amplify or stabilize resin-dentin bonding. According to studies retrieved for full text reading (2014-2017), there are currently six major strategies available to overcome resin-dentin bond degradation: (i) use of collagen crosslinking agents, which may form stable covalent bonds with collagen fibrils, thus strengthening the hybrid layer; (ii) use of antioxidants, which may allow further polymerization reactions over time; (iii) use of protease inhibitors, which may inhibit or inactivate metalloproteinases; (iv) modification of the bonding procedure, which may be performed by using the ethanol wet-bonding technique or by applying an additional adhesive (hydrophobic) coating, thereby strengthening the hybrid layer; (v) laser treatment of the substrate prior to bonding, which may cause specific topographic changes in the surface of dental substrates, increasing bonding efficacy; and (vi) reinforcement of the resin matrix with inorganic fillers and/or remineralizing agents, which may positively enhance physico-mechanical properties of the hybrid layer. With the present review, we contributed to the better understanding of adhesion concepts and mechanisms of resin-dentin bond degradation, showing the current prospects available to solve that problematic. Also, adhesively-bonded restorations may be benefited by the use of some biomolecules, nanocompounds or alternative bonding strategies in order to minimize bond strength degradation.

  12. Concerning the etiology of bony bridges along the sides of the terminal phalanx of the great toe

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, E.

    1987-06-01

    Besides in acromegaly bony bridges at the terminal phalanx of the great toe occur in one third of cases with peripheral signs of diffuse idiopathic skeletal hyperostosis, systemic diseases as rheumatoid arthritis or psoriatic arthritis with chronic inflammation of the interphalangeal joint of the great toe respectively extraarticular osseous changes in the terminal phalanx of the great toe do not influence the development of such bridges.

  13. Comparative evaluation of shear bond strength of metallic brackets bonded with two different bonding agents under dry conditions and with saliva contamination.

    Science.gov (United States)

    Khanehmasjedi, Mashallah; Naseri, Mohammad Ali; Khanehmasjedi, Samaneh; Basir, Leila

    2017-02-01

    This study compared the shear bond strength of metallic brackets bonded with Single Bond and Assure bonding agents under dry and saliva-contamination conditions. Sixty sound premolar teeth were selected, and stainless-steel brackets were bonded on enamel surfaces with Single Bond and Assure bonding agents under dry condition or with saliva contamination. Shear bond strength values of brackets were measured in a universal testing machine. The adhesive remnant index scores were determined after debonding of the brackets under a stereomicroscope. One-way analysis of variance (ANOVA) was used to analyze bond strength. Two-by-two comparisons were made with post hoc Tukey tests (pbrackets to tooth structure were 9.29±8.56 MPa and 21.25±8.93 MPa with the use of Assure resin bonding agent under saliva-contamination and dry conditions, respectively. These values were 10.13±6.69 MPa and 14.09±6.6 MPa, respectively, under the same conditions with the use of Single Bond adhesive. Contamination with saliva resulted in a significant decrease in the bond strength of brackets to tooth structure with the application of Assure adhesive resin (pbrackets to tooth structures. Contamination with saliva significantly decreased the bond strength of Assure bonding agent compared with dry conditions. Copyright © 2016. Published by Elsevier Taiwan LLC.

  14. CT of the canine lumbosacral spine in extension - flexion rotation; part I: bony window

    International Nuclear Information System (INIS)

    Henninger, W.; Werner, G.

    2002-01-01

    The canine lumbosacral spine is examined radiographically in extended and flexed lateral position as well as ventrodorsally. Superimposition of bones hinders exact evaluation of the lumbosacral intervertebral foramen in case of cauda equina syndrome, especially when degenerative changes overlap. CT or MRI are more and more indicated to get reliable findings because myelography is not always of diagnostic value. For this study twelve dogs (7 German Shepherd dogs, 4 Cross-breds, and 1 Rottweiler) of different age and sex were taken which had been referred for CT examination of the lumbosacral area. Plain radiographs did not show abnormalities. The anaesthetized dogs were positioned in dorsal recumbency with the legs firstly extended and secondly flexed according to flexion-extension radiography. Slice thickness was 2 mm, the CT images were evaluated in both bony and soft tissue windows. Bony window easily showed vertebral bodies, vertebral canal, pedicles, vertebral laminae, and articular processes of L7 and S1. Median height of the vertebral canal did not change during extension or flexion at the level of L7 and the sacrum. Height and width of the intervertebral foramen and width of the interarcual foramen changed markedly from extension to flexion. Lateral recessus of the vertebral canal always could be observed as ventrolateral widening. In sagittal CT scans of the lumbosacral specimen of a normal German Shepherd dog cranial articular processes of the sacrum were detected to be responsible for maximum height or width of the intervertebral foramen. Evolving from the lateral recessus the intervertebral foramen was initially oval-shaped and got rounded and narrowed by the cranial articular process of the sacrum. Position and shape of the cranial articular processes of the sacrum were evaluated. Surface of the cranial articular processes of S1 were found even with articular spaces congruent, but some also appeared slightly concave or convex where incongruity of the

  15. Strength of Al and Al-Mg/alumina bonds prepared using ultrahigh vacuum diffusion bonding

    International Nuclear Information System (INIS)

    King, W.E.; Campbell, G.H.; Wien, W.L.; Stoner, S.L.

    1994-01-01

    The authors have measured the cross-breaking strength of Al and Al-Mg alloys bonded with alumina. Diffusion bonding of Al and Al-Mg alloys requires significantly more bonding time than previously thought to obtain complete bonding. In contrast to previous diffusion bonding studies, fracture morphologies are similar to those obtained in bonds formed by liquid phase reaction; i.e., bonds are as strong or stronger than the ceramic; and fracture tends to propagate in the metal for pure Al and near the interface in the ceramic for the alloys. There are indications that the fracture morphology depends on Mg content and therefore on plasticity in the metal

  16. Performance Evaluation and Durability Studies of Adhesive Bonds

    Science.gov (United States)

    Ranade, Shantanu Rajendra

    In this thesis, four test approaches were developed to characterize the adhesion performance and durability of adhesive bonds for specific applications in areas spanning from structural adhesive joints to popular confectionaries such as chewing gum. In the first chapter, a double cantilever beam (DCB) specimen geometry is proposed for combinatorial fracture studies of structural adhesive bonds. This specimen geometry enabled the characterization of fracture energy vs. bondline thickness trends through fewer tests than those required during a conventional "one at a time" characterization approach, potentially offering a significant reduction in characterization times. The second chapter investigates the adhesive fracture resistance and crack path selection in adhesive joints containing patterns of discreet localized weak interfaces created using physical vapor deposition of copper. In a DCB specimen tested under mode-I conditions, fracture energy within the patterned regions scaled according to a simple rule of mixture, while reverse R-curve and R-curve type trends were observed in the regions surrounding weak interface patterns. Under mixed mode conditions such that bonding surface with patterns is subjected to axial tension, fracture energy did not show R-curve type trends while it was observed that a crack could be made to avoid exceptionally weak interfaces when loaded such that bonding surface with defects is subjected to axial compression. In the third chapter, an adaptation of the probe tack test is proposed to characterize the adhesion behavior of gum cuds. This test method allowed the introduction of substrates with well-defined surface energies and topologies to study their effects on gum cud adhesion. This approach and reported insights could potentially be useful in developing chewing gum formulations that facilitate easy removal of improperly discarded gum cuds from adhering surfaces. In the fourth chapter we highlight a procedure to obtain insights

  17. Comparison of shear bond strength of stainless steel brackets bonded with three light- cured adhesives

    Directory of Open Access Journals (Sweden)

    Zahra Minaei Basharik

    2015-09-01

    Full Text Available Introduction: The bonding process of the brackets to enamel has been a critical issue in orthodontic research. The purpose of this study was to evaluate the shear bond strength of 3 light-cured adhesives (transbond XT, Z250, light bond. Materials &Methods: In this study sixty extracted human premolars were collected and randomly divided into 3 test groups. All teeth were etched by 37% phosphoric acid. In first group brackets were bonded by Transbond XT adhesive, in group two brackets were bonded by Light bond adhesive and in third group were bonded by filtek Z250 composite. All of them were cured with Ortholux xt for 40 seconds.24 hours after thermocycling, Shear Bond Strength (SBS values of these brackets were recorded using a Universal Testing Machine. Adhesive Remnant Index (ARI scores were determined after the failure of the brackets, using Stereo Microscope the data were analyzed using ANOVA and Chi-square tests. Results: Mean shear bond strength of Transbond XT, light bond and Z250 were 28.9±2.25 MPa, 25.06±1.98 MPa and 26.8±2.57 MPa, respectively. No significant difference was observed in the SBS among the groups and a clinically acceptable SBS was found for the three adhesives. ARI scores were not significantly different between the various groups (P>0.05. Conclusion: This study showed that the Z250 can be used as light bond and transbond xt to bond orthodontic brackets and ARI and SBS scores were not significantly different.

  18. Implant-Supported Telescopic Crown-Retained Overdentures for Oral Rehabilitation of Patients with Severe Bony Defects: A 5-Year Retrospective Study.

    Science.gov (United States)

    Zou, Duohong; Wang, Feng; Wu, Yiqun; Huang, Wei; Zhang, Chenping; Zhang, Zhiyuan

    2015-01-01

    To evaluate the performance of dental implant-supported telescopic crown (TC)-retained overdentures to restore the oral function of patients who have insufficient jawbone volume resulting from tumor resection or trauma. From January 2004 to December 2008, implant-supported TC-retained overdentures were used to restore the oral function of patients with severe bony defects resulting from tumor resection or trauma. Clinical data, including implant success and survival rates, biologic and mechanical complications, prosthodontic maintenance efforts, and patient satisfaction, were analyzed annually after delivery of the final prostheses. Twenty-four patients were treated, and a total of 88 implants were inserted to support TC-retained overdentures. The mean modified plaque index of implants remained low (76.3%) in the study showed the absence of bleeding on probing at follow-up visits. Peri-implant marginal bone loss (MBL) ranged from 0.8 to 1.2 mm. There was no statistically significant difference in the MBL between maxillary and mandibular implants (P = .43). The implant success rate was 100% after 5 years, and the prosthodontic maintenance and complication rate was 0.22 times per year. More than 90% of patients were satisfied with the restoration of their oral function using TCs. Based on our study of 24 patients treated with TC-retained overdentures, it appears that this treatment may be a viable option for patients with insufficient jawbone volume.

  19. A Comparative Evaluation of the Effect of Bonding Agent on the Tensile Bond Strength of Two Pit and Fissure Sealants Using Invasive and Non-invasive Techniques: An in-vitro Study.

    Science.gov (United States)

    Singh, Shamsher; Adlakha, Vivek; Babaji, Prashant; Chandna, Preetika; Thomas, Abi M; Chopra, Saroj

    2013-10-01

    Newer technologies and the development of pit and fissure sealants have shifted the treatment philosophy from 'drill and fill' to that of 'seal and heal'. The purpose of this in-vitro study was to evaluate the effects of bonding agents on the tensile bond strengths of two pit and fissure sealants by using invasive and non-invasive techniques. One hundred and twenty bicuspids were collected and teeth were divided into two groups: Group-I (Clinpro) and Group-II (Conseal f) with 60 teeth in each group. For evaluating tensile bond strengths, occlusal surfaces of all the teeth were flattened by reducing buccal and lingual cusps without disturbing fissures. Standardised polyvinyl tube was bonded to occlusal surfaces with respective materials. Sealants were applied, with or without bonding agents, in increments and they were light cured. Tensile bond strengths were determined by using Universal Testing Machine. Data were then statistically analysed by using Student t-test for comparison. A statistically significant difference was found in tensile bond strength in invasive with bonding agent group than in non-invasive with bonding agent group. This study revealed that invasive techniques increase the tensile bond strengths of sealants as compared to non- invasive techniques and that the use of a bonding agent as an intermediate layer between the tooth and fissure sealant is beneficial for increasing the bond strength.

  20. Are Bonding Agents being Effective on the Shear Bond Strength of Orthodontic Brackets Bonded to the Composite?

    Directory of Open Access Journals (Sweden)

    Fahimeh Farzanegan

    2014-06-01

    Full Text Available Introduction: One of the clinical problems in orthodontics is the bonding of brackets tocomposite restorations. The aim of this study was to evaluate the shear bondstrength of brackets bonded to composite restorations using Excite. Methods:Forty brackets were bonded to composite surfaces, which were embedded inacrylic resin. One of the following four protocols was employed for surfacepreparation of the composite: group 1 37% phosphoric acid for 60 seconds, group2 roughening with a diamond bur plus 37% phosphoric acid for 60 seconds, group3 37% phosphoric acid for 60 seconds and the applying Excite®, group4 roughening with diamond bur plus 37% phosphoric acid for 60 seconds andapplying Excite®. Maxillary central brackets were bonded onto thecomposite prepared samples with Transbond XT. Shear Bond Strength (SBS wasmeasured by a universal testing machine. The ANOVA and Tukey test was utilizedfor data analysis. Results: There was a significant difference betweenthe four groups (P

  1. MUNICIPAL BONDS AS THE FINANCING STRATEGY FOR URBAN INFRASTRUCTURE : CASE STUDY OF JAKARTA MRT

    Directory of Open Access Journals (Sweden)

    Eko Nur Surachman

    2016-10-01

    Full Text Available The construction of Jakarta MRT Phase I has been carried out by using funds from foreign debt. Meanwhile, Jakarta MRT Phase II or other local infrastructure projects are still waiting for new funding scheme. One alternative is municipal bonds. This study investigate the possibilities of using municipal bonds to finance urban infrastructure project with the case study of Jakarta MRTPhase I. The analyzed use three perspectives including financial aspect, legal aspect, and Jakarta financial capacity aspect. financial analysis using discounted cash flow (DCF, net present value (NPV and internal rate of return (IRR.Secondly, study literature is used in the legal analysis by exploring specific regulations regarding the municipal bonds. Finally, the Jakarta Regional Budget and Jakarta Budget Audit Report is examined to get insight and depth information regarding its financial capacity. The result is municipal bonds are feasible as the source of financing Jakarta MRT Project.

  2. Bony integration of titanium implants with a novel bioactive calcium titanate (Ca4Ti3O10) surface treatment in a rabbit model.

    Science.gov (United States)

    Haenle, Maximilian; Lindner, Tobias; Ellenrieder, Martin; Willfahrt, Manfred; Schell, Hanna; Mittelmeier, Wolfram; Bader, Rainer

    2012-10-01

    Nowadays total joint replacement is an indispensable component of modern medicine. The surfaces characteristics of cementless prostheses may be altered to achieve an accelerated and enduring bony integration. Classic surface coatings bear the risk of loosening or flaking from the implant body. This risk is excluded by the chemical conversion of the naturally existing TiO(2) surface layer into calcium titanate. The aim of this experimental animal study was to investigate the bony integration of implants with a new calcium titanate surface (Ca(4)Ti(3)O(10)) compared with a conventional standard Ti6Al4V surface. Cylindrical implants, made of titanium alloy (Ti6Al4V) were implanted in both lateral femoral condyles of New Zealand white rabbits. In each animal, an implant with and without surface treatment was inserted in a blinded manner. Animals were sacrificed after 4, 12, and 36 weeks, respectively. The axial pull-off forces were determined for 25 animals using a universal testing machine (Zwick Z010, Ulm, Germany). Furthermore, a histological analysis of the bony integration of the implants was performed in 12 specimens. In general, the pull-off forces for untreated and treated implants increased with longer survival times of the rabbits. No significant difference could be shown after 4 weeks between treated and untreated implants. After 12 weeks, the treated implants revealed a statistical significant higher pull-off force. After 36 weeks, the pull-off forces for treated and untreated implants aligned again. Titanium implants treated with calcium titanate, may offer an interesting and promising implant surface modification for endoprosthetic implants. They might lead to an accelerated osseointegration of total hip and knee replacements. Copyright © 2012 Wiley Periodicals, Inc.

  3. Manufacturing study of Be, W and CFC bonded structures for plasma-facing components

    Science.gov (United States)

    Onozuka, M.; Hirai, S.; Kikuchi, K.; Oda, Y.; Shimizu, K.

    2004-08-01

    A manufacturing study has been conducted for Be, W, and CFC bonded structures employed in plasma-facing components for the ITER. For Be tiles bonded to the Cu-Cr-Zr alloy heat sink with stainless-steel cooling pipes, a one-axis hot press with two heating processes has been used to bond the three materials. An Al-Si base interlayer has been used to bond Be to the Cu-alloy. The heating processes have been selected to match the required heat treatment conditions for the Cu-alloy. Because of the limited heat processes using a conventional hot press, the manufacturing cost can be minimized. For both the W and CFC tiles, the materials have been brazed at the same time to the Cu-alloy. Ni-Cu-Mn and Cu-Ti brazing materials have been used for the W and CFC tiles, respectively. Using the above bonding techniques, partial mockups of a blanket first-wall panel and divertor target have been successfully manufactured.

  4. Manufacturing study of Be, W and CFC bonded structures for plasma-facing components

    International Nuclear Information System (INIS)

    Onozuka, M.; Hirai, S.; Kikuchi, K.; Oda, Y.; Shimizu, K.

    2004-01-01

    A manufacturing study has been conducted for Be, W, and CFC bonded structures employed in plasma-facing components for the ITER. For Be tiles bonded to the Cu-Cr-Zr alloy heat sink with stainless-steel cooling pipes, a one-axis hot press with two heating processes has been used to bond the three materials. An Al-Si base interlayer has been used to bond Be to the Cu-alloy. The heating processes have been selected to match the required heat treatment conditions for the Cu-alloy. Because of the limited heat processes using a conventional hot press, the manufacturing cost can be minimized. For both the W and CFC tiles, the materials have been brazed at the same time to the Cu-alloy. Ni-Cu-Mn and Cu-Ti brazing materials have been used for the W and CFC tiles, respectively. Using the above bonding techniques, partial mockups of a blanket first-wall panel and divertor target have been successfully manufactured

  5. Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study.

    Science.gov (United States)

    Mirzakouchaki, Behnam; Shirazi, Sajjad; Sharghi, Reza; Shirazi, Samaneh; Moghimi, Mahsan; Shahrbaf, Shirin

    2016-02-01

    Different in-vitro studies have reported various results regarding shear bond strength (SBS) of orthodontic brackets when SEP technique is compared to conventional system. This in-vivo study was designed to compare the effect of conventional acid-etching and self-etching primer adhesive (SEP) systems on SBS and debonding characteristics of metal and ceramic orthodontic brackets. 120 intact first maxillary and mandibular premolars of 30 orthodontic patients were selected and bonded with metal and ceramic brackets using conventional acid-etch or self-etch primer system. The bonded brackets were incorporated into the wire during the study period to simulate the real orthodontic treatment condition. The teeth were extracted and debonded after 30 days. The SBS, debonding characteristics and adhesive remnant indices (ARI) were determined in all groups. The mean SBS of metal brackets was 10.63±1.42 MPa in conventional and 9.38±1.53 MPa in SEP system, (P=0.004). No statistically significant difference was noted between conventional and SEP systems in ceramic brackets. The frequency of 1, 2 and 3 ARI scores and debonding within the adhesive were the most common among all groups. No statistically significant difference was observed regarding ARI or failure mode of debonded specimens in different brackets or bonding systems. The SBS of metal brackets bonded using conventional system was significantly higher than SEP system, although the SBS of SEP system was clinically acceptable. No significant difference was found between conventional and SEP systems used with ceramic brackets. Total SBS of metal brackets was significantly higher than ceramic brackets. Due to adequate SBS of SEP system in bonding the metal brackets, it can be used as an alternative for conventional system. Shear bond strength, Orthodontic brackets, Adhesive remnant index, self-etch.

  6. Unique Bond Breaking in Crystalline Phase Change Materials and the Quest for Metavalent Bonding.

    Science.gov (United States)

    Zhu, Min; Cojocaru-Mirédin, Oana; Mio, Antonio M; Keutgen, Jens; Küpers, Michael; Yu, Yuan; Cho, Ju-Young; Dronskowski, Richard; Wuttig, Matthias

    2018-05-01

    Laser-assisted field evaporation is studied in a large number of compounds, including amorphous and crystalline phase change materials employing atom probe tomography. This study reveals significant differences in field evaporation between amorphous and crystalline phase change materials. High probabilities for multiple events with more than a single ion detected per laser pulse are only found for crystalline phase change materials. The specifics of this unusual field evaporation are unlike any other mechanism shown previously to lead to high probabilities of multiple events. On the contrary, amorphous phase change materials as well as other covalently bonded compounds and metals possess much lower probabilities for multiple events. Hence, laser-assisted field evaporation in amorphous and crystalline phase change materials reveals striking differences in bond rupture. This is indicative for pronounced differences in bonding. These findings imply that the bonding mechanism in crystalline phase change materials differs substantially from conventional bonding mechanisms such as metallic, ionic, and covalent bonding. Instead, the data reported here confirm a recently developed conjecture, namely that metavalent bonding is a novel bonding mechanism besides those mentioned previously. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. The Strength of Hydrogen Bonds between Fluoro-Organics and Alcohols, a Theoretical Study.

    Science.gov (United States)

    Rosenberg, Robert E

    2018-05-10

    Fluorinated organic compounds are ubiquitous in the pharmaceutical and agricultural industries. To better discern the mode of action of these compounds, it is critical to understand the strengths of hydrogen bonds involving fluorine. There are only a few published examples of the strengths of these bonds. This study provides a high level ab initio study of inter- and intramolecular hydrogen bonds between RF and R'OH, where R and R' are aryl, vinyl, alkyl, and cycloalkyl. Intermolecular binding energies average near 5 kcal/mol, while intramolecular binding energies average about 3 kcal/mol. Inclusion of zero-point energies and applying a counterpoise correction lessen the difference. In both series, modest increases in binding energies are seen with increased acidity of R'OH and increased electron donation of R in RF. In the intramolecular compounds, binding energy increases with the rigidity of the F-(C) n -OH ring. Inclusion of free energy corrections at 298 K results in exoergic binding energies for the intramolecular compounds and endoergic binding energies for the intermolecular compounds. Parameters such as bond lengths, vibrational frequencies, and atomic populations are consistent with formation of a hydrogen bond and with slightly stronger binding in the intermolecular cases over the intramolecular cases. However, these parameters correlated poorly with binding energies.

  8. Chemical activation of molecules by metals: Experimental studies of electron distributions and bonding

    International Nuclear Information System (INIS)

    Lichienberger, D.L.

    1990-10-01

    This quarter has witnessed further progress both in our experimental methods of photoelectron spectroscopy and in our understanding the fundamental relationships between ionization energies and the chemistry of transition metal species. Progress continues on the new gas phase photoelectron spectrometer that combine improved capabilities for HeI/HeII UPS, XPS, and Auger investigations of organometallic molecules. Several measurements have been accomplished this year that were not possible previously. We have published the formal relationship between measured molecular ionization energies and thermodynamic bond dissociation energies, and applied the relationships to homonuclear and heteronuclear diatomic molecules, multiple bonds, and metal-ligand bonds. Studies of C-H bond activation have continued with examination of different degrees of Si-H bond addition to metals. the electronic effects of intermolecular interactions have been observed by comparing the ionizations of metal complexes in the gas phase with the ionizations of monolayer solid organometallic films prepared in ultra-high vacuum. The orientations of the molecules have been determined by scanning tunneling microscopy. Especially interesting has been the recent application of these techniques to the characterization of the soccer-ball shaped C 60 molecule, buckminsterfullerene. Studies of the following complexes are described : Fe, Os, Nb, Mo, Rh, Re, Al, and Mn. 19 refs

  9. thermodynamic stability of hydrogen-bonded nanostructures: a calorimetric study

    NARCIS (Netherlands)

    ten Cate, M.G.J.; Huskens, Jurriaan; Crego Calama, Mercedes; Reinhoudt, David

    2004-01-01

    The self-assembly of hydrogen-bonded aggregates (rosettes) in solvent mixtures of different polarity has been studied by calorimetry. The C50 parameter, the concentration when 50 % of the components are incorporated in the assembly, is used to compare assemblies with different stoichiometry. C50 for

  10. Comparison of Shear Bond Strengths of three resin systems for a Base Metal Alloy bonded to

    Directory of Open Access Journals (Sweden)

    Jlali H

    1999-12-01

    Full Text Available Resin-bonded fixed partial dentures (F.P.D can be used for conservative treatment of partially edentulous"npatients. There are numerous studies regarding the strength of resin composite bond to base meta! alloys. Shear bond"nstrength of three resin systems were invistigated. In this study these systems consisted of: Panavia Ex, Mirage FLC and"nMarathon V. Thirty base metal specimens were prepared from rexillium III alloy and divided into three groups. Then each"ngroup was bonded to enamel of human extracted molar teeth with these systems. All of specimens were stored in water at"n37ac for 48 hours. A shear force was applied to each specimen by the instron universal testing machine. A statistical"nevaluation of the data using one-way analysis of variance showed that there was highly significant difference (P<0.01"nbetween the bond strengths of these three groups."nThe base metal specimens bonded with panavia Ex luting agent, exhibited the highest mean bond strength. Shear bond"nstrength of the specimens bonded to enamel with Mirage F1C showed lower bond strenght than panavia EX. However, the"nlowest bond strength was obtained by the specimens bonded with Marathon V.

  11. Association of bond, market, operational, and financial factors with multi-hospital system bond issues.

    Science.gov (United States)

    Carpenter, C E; McCue, M J; Hossack, J B

    2001-01-01

    Despite the growth of multi-hospital systems in the 1990s, their performance in the tax-exempt bond market has not been adequately evaluated. The purpose of this study is to compare bonds issued by multi-hospital systems to those issued by individual hospitals in terms of bond, market, operational, and financial characteristics. The study sample includes 2,078 newly issued, tax-exempt, revenue bonds between 1991 and 1997. The findings indicate that multi-hospital systems issued larger amounts of debt at a lower cost, were more likely to be insured, had higher debt service coverage and higher operating margins.

  12. Communication: A hydrogen-bonded difluorocarbene complex: Ab initio and matrix isolation study

    Science.gov (United States)

    Sosulin, Ilya S.; Shiryaeva, Ekaterina S.; Tyurin, Daniil A.; Feldman, Vladimir I.

    2017-10-01

    Structure and spectroscopic features of the CF2⋯HF complexes were studied by ab initio calculations at the CCSD(T) level and matrix isolation FTIR spectroscopy. The calculations predict three stable structures. The most energetically favorable structure corresponds to hydrogen bonding of HF to the lone pair of the C atom (the interaction energy of 3.58 kcal/mol), whereas two less stable structures are the H⋯F bonded complexes (the interaction energies of 0.30 and 0.24 kcal/mol). The former species was unambiguously characterized by the absorptions in the FTIR spectra observed after X-ray irradiation of fluoroform in a xenon matrix at 5 K. The corresponding features appear at 3471 (H-F stretching), 1270 (C-F symmetric stretching, shoulder), 1175 (antisymmetric C-F stretching), and 630 (libration) cm-1, in agreement with the computational predictions. To our knowledge, it is the first hydrogen-bonded complex of dihalocarbene. Possible weaker manifestations of the H⋯F bonded complexes were also found in the C-F stretching region; however, their assignment is tentative. The H⋯C bonded complex is protected from reaction yielding a fluoroform molecule by a remarkably high energy barrier (23.85 kcal/mol), so it may be involved in various chemical reactions.

  13. Evolution of the bonding mechanism of ZnO under isotropic compression: A first-principles study

    International Nuclear Information System (INIS)

    Zhou, G.C.; Sun, L.Z.; Wang, J.B.; Zhong, X.L.; Zhou, Y.C.

    2008-01-01

    The electronic structure and the bonding mechanism of ZnO under isotropic pressure have been studied by using the full-potential linear augmented plane wave (FP-LAPW) method within the density-functional theory (DFT) based on LDA+U exchange correlation (EXC) potential. We used the theory of Atoms in Molecules (AIM) method to analyze the change of the charge transfer and the bonding strength under isotropic pressure. The results of the theoretical analysis show that charge transfer between Zn and O atomic basins nearly linearly increases with the increasing pressure. Charge density along the Zn-O bond increases under the high pressure. The bonding strength and the ionicity of Zn-O bond also increase with the increasing pressure. The linear evolution process of the bonding mechanism under isotropic pressure was shown clearly in the present paper

  14. Shear bond strength of precoated orthodontic brackets: an in vivo study

    OpenAIRE

    Hassan, Ali H

    2010-01-01

    Ali H HassanDepartment of Preventive Dental Sciences, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi ArabiaObjective: To evaluate the shear bond strength of precoated orthodontic brackets bonded with self-etching primer relative to that of noncoated conventionally-bonded brackets at two different time intervals.Methods: Twenty-one subjects were selected for randomized split-mouth bonding of two types of brackets to the maxillary arch. Half of the teeth had precoated brackets b...

  15. Theoretical and Experimental Study on Vibration Propagation in PMMA Components in Ultrasonic Bonding Process

    Directory of Open Access Journals (Sweden)

    Yibo Sun

    2017-03-01

    Full Text Available Ultrasonic bonding has an increasing application in the micro assembly of polymeric micro-electro mechanical systems (MEMS with high requirements for fusion precision. In the ultrasonic bonding process, the propagation of ultrasonic vibration in polymer components is related to the interfacial fusion, which can be used as a monitoring parameter to control ultrasonic energy. To study the vibration propagation in viscoelastic polymer components, finite element analysis on the bonding of poly methyl methacrylate (PMMA micro connector to substrate for microfluidic system is carried out. Curves of propagated vibration amplitude corresponding to interfacial temperatures are obtained. The ultrasonic vibration propagated in PMMA components are measured through experiments. The theoretical and experimental results are contrasted to analyze the change mechanism of vibration propagation related to temperature. Based on the ultrasonic bonding process controlled by the feedback of vibration propagation, interfacial fusions at different vibration propagation states are obtained through experiments. Interfacial fusion behavior is contrasted to the propagated vibration amplitude in theoretical and experimental studies. The relation between vibration propagation and fusion degree is established with the proper parameter range for the obtained high quality bonding.

  16. X-ray and neutron tomography on the bony inner ear of baleen whales; Roentgen- und Neutronentomographie am knoechernen Innenohr der Bartenwale

    Energy Technology Data Exchange (ETDEWEB)

    Arlt, Tobias [Technische Univ. Berlin (Germany); Wieder, Frank [Bundesanstalt fuer Materialforschung und -pruefung BAM, Berlin (Germany). Fachgruppe 8.3 ' ' Radiologische Verfahren' ' ; Hilger, Andre; Kardjilov, Nikolay [Helmholtz-Zentrum Berlin HZB, Berlin (Germany); Hampe, Oliver [Museum fuer Naturkunde, Berlin (Germany); Manke, Ingo [Helmholtz-Zentrum Berlin (HZB) fuer Materialien und Energie, Berlin (Germany). Fachgruppe ' ' Bildgebende Verfahren' ' ; Ritsche, Indira; Fahlke, Julia M.

    2018-04-01

    During their evolution whales and dolphins developed a highly specialized hearing organ for orientation in their deep sea territory covering a broad acoustic spectrum. The internal anatomy of the periotic bone, especially the morphology of the cochlea, has a significant influence on the hearing capability of mammals. The bony and fossilized cochleae of several fossil representatives of extinct baleen whales (e.g., Cetotheriidae) and modern rorquals (Balaenopteridae) and right whales, as well as cochleae of an archaeocete and some land mammals are investigated by X-ray and neutron tomography in order to record morphological changes that may be responsible for the development of low frequency hearing. Differences in the cochlear morphology have been determined by means of morphometric parameters, such as the number of turns, the length of the cochlea, and the curvature of the cochlear canal. In particular, X-ray tomography enables a high resolution display of the bony inner ear.

  17. Effect of organic molecules on hydrolysis of peptide bond: A DFT study

    International Nuclear Information System (INIS)

    Makshakova, Olga; Ermakova, Elena

    2013-01-01

    Highlights: ► DFT study of the effects of small organic molecules on the hydrolysis reactions of peptide bonds. ► Organic molecules can activate nonenzymatic hydrolysis reaction. ► Influence of organic acids on activation energy barrier correlates with their electronegativity. - Abstract: The activation and inhibition effects of small organic molecules on peptide hydrolysis have been studied using a model compound dialanine and DFT approach. Solvent-assisted and non-assisted concerted mechanisms were analyzed. Several transition states for the systems: alanine dipeptide–water molecule in complexes with alcohol molecules, acetonitrile, dimethylsulfoxide, propionic, lactic and pyruvic acids and water molecules were localized. The formation of hydrogen bonds between dipeptide, reactive water molecule and molecules of solvents influences the activation energy barrier of the peptide bond hydrolytic reaction. Strong effect of organic acids on the activation energy barrier correlates with their electronegativity. Acetonitrile can act as an inhibitor of reaction. Mechanisms of regulation of the activation energy barrier are discussed in the terms of donor-acceptor interactions

  18. Enamel Bond Strength of New Universal Adhesive Bonding Agents.

    Science.gov (United States)

    McLean, D E; Meyers, E J; Guillory, V L; Vandewalle, K S

    2015-01-01

    Universal bonding agents have been introduced for use as self-etch or etch-and-rinse adhesives depending on the dental substrate and clinician's preference. The purpose of this study was to evaluate the shear bond strength (SBS) of composite to enamel using universal adhesives compared to a self-etch adhesive when applied in self-etch and etch-and-rinse modes over time. Extracted human third molars were used to create 120 enamel specimens. The specimens were ground flat and randomly divided into three groups: two universal adhesives and one self-etch adhesive. Each group was then subdivided, with half the specimens bonded in self-etch mode and half in etch-and-rinse mode. The adhesives were applied as per manufacturers' instructions, and composite was bonded using a standardized mold and cured incrementally. The groups were further divided into two subgroups with 10 specimens each. One subgroup was stored for 24 hours and the second for six months in 37°C distilled water and tested in shear. Failure mode was also determined for each specimen. A three-way analysis of variance (ANOVA) found a significant difference between groups based on bonding agent (p0.05). Clearfil SE in etch-and-rinse and self-etch modes had more mixed fractures than either universal adhesive in either mode. Etching enamel significantly increased the SBS of composite to enamel. Clearfil SE had significantly greater bond strength to enamel than either universal adhesive, which were not significantly different from each other.

  19. Bony fusion of the maxilla and mandible as a sequelae of noma: A rare case report

    Energy Technology Data Exchange (ETDEWEB)

    Bagewadi, Shivanand B.; Awasthi, Ujjwala Rastogi; Mody, Bharat M.; Suma, Gundareddy N.; Garg, Shruti [Dept. of Medicine and Radiology, ITS Center for Dental Studies and Research, Ghaziabad, Uttar Pradesh (Korea, Republic of)

    2015-09-15

    Noma is a gangrenous disease of the orofacial region that leads to severe facial tissue destruction and is a significant cause of death among children. With the advent of modern antibiotics and improved nutrition, children with noma may survive into adulthood, but must face the challenge of undergoing repair of the sequelae of noma. This report describes a case of bony fusion of the maxilla and mandible in a 28-year-old female patient, which was a sequelae of a childhood case of noma.

  20. Experimental study on flexural members strengthened with variable bonded pre-stressed CFRP plates

    Science.gov (United States)

    Zhang, Baojing; Shang, Shouping

    2017-08-01

    Aiming at the problem that the structural adhesive between CFRP and concrete interface is aging with time and then lost the bond strength, the concept of variable bond prestressed CFRP is put forward. In order to obtain the bearing capacity and failure pattern of the beam strengthened with variable bonding prestressed CFRP plate, three concrete beams of 5.6m long were strengthened by the technology of non-bonding, bonding and variable bonding strengthened with prestressed CFRP plates respectively, the mechanical properties and crack changes of the test beams under three conditions had been compared and analyzed. Test results show that the variable bond strengthened with prestressed CFRP plates with unbonded prestressed CFRP, cracking load was increased by 36%, yield load increased by 4%, the ultimate load increased by 12%; The reinforcement technology of variable bonding prestressed CFRP plate has the characteristics of non-bonding and bonding prestressed CFRP plate reinforcement, which is similar to that of the bonded reinforcement in the early stage of the development of the cracks, then is gradually developing into the non-bonding prestressed reinforcement, the crack spacing and width have the same characteristics as the bonding reinforcement (both crack spacing and width are small), which is more conducive to enhance the durability of the structure.

  1. Studies of Metal-Metal Bonded Compounds in Catalysis

    Energy Technology Data Exchange (ETDEWEB)

    Berry, John F. [Univ. of Wisconsin, Madison, WI (United States)

    2018-01-19

    The overall goals of this research are (1) to define the fundamental coordination chemistry underlying successful catalytic transformations promoted by metal-metal bonded compounds, and (2) to explore new chemical transformations that occur at metal-metal bonded sites that could lead to the discovery of new catalytic processes. Transformations of interest include metal-promoted reactions of carbene, nitrene, or nitrido species to yield products with new C–C and C–N bonds, respectively. The most promising suite of transition metal catalysts for these transformations is the set of metal-metal bonded coordination compounds of Ru and Rh of the general formula M2(ligand)4, where M = Ru or Rh and ligand = a monoanionic, bridging ligand such as acetate. Development of new catalysts and improvement of catalytic conditions have been stymied by a general lack of knowledge about the nature of highly reactive intermediates in these reactions, the knowledge that is to be supplied by this work. Our three specific objectives for this year have been (A) to trap, isolate, and characterize new reactive intermediates of general relevance to catalysis, (B) to explore the electronic structure and reactivity of these unusual species, and how these two properties are interrelated, and (C) to use our obtained mechanistic knowledge to design new catalysts with a focus on Earth-abundant first-row transition metal compounds.

  2. Optimising hydrogen bonding in solid wood

    DEFF Research Database (Denmark)

    Engelund, Emil Tang

    2009-01-01

    The chemical bonds of wood are both covalent bonds within the wood polymers and hydrogen bonds within and between the polymers. Both types of bonds are responsible for the coherence, strength and stiffness of the material. The hydrogen bonds are more easily modified by changes in load, moisture...... and temperature distorting the internal bonding state. A problem arises when studying hydrogen bonding in wood since matched wood specimens of the same species will have very different internal bonding states. Thus, possible changes in the bonding state due to some applied treatment such as conditioning...... maintaining 100 % moisture content of the wood. The hypothesis was that this would enable a fast stress relaxation as a result of reorganization of bonds, since moisture plasticizes the material and temperature promotes faster kinetics. Hereby, all past bond distortions caused by various moisture, temperature...

  3. Bony changes in cows affected with chronic fluorine poisoning caused by industrial waste

    Energy Technology Data Exchange (ETDEWEB)

    Lasarov, E; Tatarov, B; Dimitrov, G; Kantschev, L; Kovatschev, K

    1972-01-01

    Cows affected with chronic fluorine poisoning were thoroughly examined and the findings ff clinical, anatomical-pathological, x-ray, chemical and histological examinations are reported with particular reference to changes of skeletal bones. The most significant bony changes were periosteal hyperostosis on metacarpal and metatarsal bones, local resorption of the compact substance which appeared to have a sponge-like pattern, and a destructive process in the areas surrounding Havers' and Volkmann's canals. Changes of the trabecular pattern were observed in the spongy substance of the above mentioned bones. Trabeculae showed signs of atrophy - they were thinned or coarsely thickened - and their contours were well contrasted. Regularly shaped osteons were not frequently found in the spongy substance. Marked narrowing of the medullary canal was seen.

  4. The bony crescent sign - a new sign of facial nerve schwannoma

    International Nuclear Information System (INIS)

    Watts, A.; Fagan, P.

    1992-01-01

    Schwannomas are relatively uncommon intracranial tumours. They most commonly involve the acoustic nerve followed in frequency by the trigeminal nerve. Other cranial nerves are rarely involved. Facial nerve schwannomas occurring within the petrous temporal bone are very rare. Their diagnosis may be missed prospectively even when appropriate computerized tomography (CT) scans are performed. Even in retrospect the site of abnormality may be difficult to identify, especially if there is an associated middle ear mass such as a cholesteatoma. In the 4 cases presented the facial nerve schwannoma was seen on high resolution CT as a soft tissue mass bounded anteriorly by a thin rim of bone. This bony crescent sign is a previously undescribed feature of facial nerve schwannoma which appears to be strongly indicative of the presence of this tumour. Recognition of this sign makes these tumours arising in the region of the geniculate ganglion easy to diagnose prospectively. 12 refs., 6 figs

  5. Experimental Study on Layered Ice Bonded Abrasive Polishing of Glass-ceramics

    Directory of Open Access Journals (Sweden)

    Yuli SUN

    2014-12-01

    Full Text Available Layered ice bonded abrasive tools (LIBAT is a new kind of one which not only has the ability of lapping and polishing but also has the effect of self-dressing. In this paper, two kinds of layered ice bonded abrasive tools were designed and manufactured. Experimental studies on layered ice bonded abrasive (LIBA polishing of glass-ceramics were conducted. The results show that the surface topography of glass-ceramics polished by micro α-Al2O3-nano α-Al2O3 LIBAT is better than that of polished by micro α-Al2O3-nano SiO2 LIBAT. The surface roughness Sa of glass-ceramics polished by the two kinds of LIBAT is at the nanometer scale. The reasons of this phenomenon were analyzed. The experimental results illustrate that the LIBAT shows good effect and can be used in production practice. DOI: http://dx.doi.org/10.5755/j01.ms.20.4.6149

  6. Unsharp masking technique as a preprocessing filter for improvement of 3D-CT image of bony structure in the maxillofacial region

    International Nuclear Information System (INIS)

    Harada, Takuya; Nishikawa, Keiichi; Kuroyanagi, Kinya

    1998-01-01

    We evaluated the usefulness of the unsharp masking technique as a preprocessing filter to improve 3D-CT images of bony structure in the maxillofacial region. The effect of the unsharp masking technique with several combinations of mask size and weighting factor on image resolution was investigated using a spatial frequency phantom made of bone-equivalent material. The 3D-CT images were obtained with scans perpendicular to and parallel to the phantom plates. The contrast transfer function (CTF) and the full width at half maximum (FWHM) of each spatial frequency component were measured. The FWHM was expressed as a ratio against the actual thickness of phantom plate. The effect on pseudoforamina was assessed using sliced CT images obtained in clinical bony 3D-CT examinations. The effect of the unsharp masking technique on image quality was also visually evaluated using five clinical fracture cases. CTFs did not change. FWHM ratios of original 3D-CT images were smaller than 1.0, regardless of the scanning direction. Those in scans perpendicular to the phantom plates were not changed by the unsharp masking technique. Those in parallel scanning were increased by mask size and weighting factor. The area of pseudoforamina decreased with increases in mask size and weighting factor. The combination of mask size 3 x 3 pixels and weighting factor 5 was optimal. Visual evaluation indicated that preprocessing with the unsharp masking technique improved the image quality of the 3D-CT images. The unsharp masking technique is useful as a preprocessing filter to improve the 3D-CT image of bony structure in the maxillofacial region. (author)

  7. Experimental Study on Bond Behavior of FRP-Concrete Interface in Hygrothermal Environment

    Directory of Open Access Journals (Sweden)

    X. H. Zheng

    2016-01-01

    Full Text Available As the technique of fiber-reinforced polymer (FRP composite material strengthened reinforced concrete structures is widely used in the field of civil engineering, durability of the strengthened structures has attracted more attention in recent years. Hygrothermal environment has an adverse effect on the bond behavior of the interface between FRP and concrete. This paper focuses on the bond durability of carbon fiber laminate- (CFL- concrete interface in hygrothermal condition which simulates the climate characteristic in South China. Twenty 100 mm × 100 mm × 720 mm specimens were divided into 6 groups based on different temperature and humidity. After pretreatment in hygrothermal environment, the specimens were tested using double shear method. Strain gauges bonded along the CFL surface and linear variation displacement transducers (LVDTs were used to measure longitudinal strains and slip of the interface. Failure mode, ultimate capacity, load-deflection relationship, and relative slip were analyzed. The bond behavior of FRP-concrete interface under hygrothermal environment was studied. Results show that the ultimate bearing capacity of the interface reduced after exposure to hygrothermal environments. The decreasing ranges were up to 27.9% after exposure at high temperature and humidity (60°C, 95% RH. The maximum strains (εmax of the specimens pretreated decreased obviously which indicated decay of the bond behavior after exposure to the hygrothermal environment.

  8. Fatigue aging of adhesive bonds

    International Nuclear Information System (INIS)

    DeLollis, N.J.

    1979-01-01

    A year long study has been made of the effect of fatigue on the bond between two epoxy encapsulant formulations and a fused alumina disc. The variables studied included isothermal aging at temperatures up to and including the cure temperature and cyclic thermal aging from +74 to -54 0 C. The encapsulants were glass microballoon filled epoxies differing only in curing agents. One was cured with an aromatic amine eutectic (Shell Curing Agent Z). The other was cured with diethanolamine. The Z cured encapsulant bond failed completely at the bond interface with little or no aging; infrared evidence indicated a soluble interlayer as a possible cause of failure. The diethanolamine cured encapsulant survived a year of isothermal aging with little or no evidence of bond degradation. Cyclic thermal aging resulted in gradual bond failure with time. An extrapolation of the cyclic aging data indicates that the stresses induced by thermal cycling would result in complete bond failure in about 1200 days

  9. Antibacterial Activity of Commercial Dentine Bonding Systems against E. faecalis–Flow Cytometry Study

    Directory of Open Access Journals (Sweden)

    Monika Lukomska-Szymanska

    2017-04-01

    Full Text Available Literature presents inconsistent results on the antibacterial activity of dentine bonding systems (DBS. Antibacterial activity of adhesive systems depends on several factors, including composition and acidity. Flow cytometry is a novel detection method to measure multiple characteristics of a single cell: total cell number, structural (size, shape, and functional parameters (viability, cell cycle. The LIVE/DEAD® BacLightTM bacterial viability assay was used to evaluate an antibacterial activity of DBS by assessing physical membrane disruption of bacteria mediated by DBS. Ten commercial DBSs: four total-etching (TE, four self-etching (SE and two selective enamel etching (SEE were tested. Both total-etching DBS ExciTE F and OptiBond Solo Plus showed comparatively low antibacterial activity against E. faecalis. The lowest activity of all tested TE systems showed Te-Econom Bond. Among SE DBS, G-ænial Bond (92.24% dead cells followed by Clearfil S3 Bond Plus (88.02% and Panavia F 2.0 ED Primer II (86.67% showed the highest antibacterial activity against E. faecalis, which was comparable to isopropranol (positive control. In the present study, self-etching DBS exhibited higher antimicrobial activity than tested total-etching adhesives against E. faecalis.

  10. Guided tissue regeneration for periodontal infra-bony defects.

    Science.gov (United States)

    Needleman, I G; Worthington, H V; Giedrys-Leeper, E; Tucker, R J

    2006-04-19

    Conventional treatment of destructive periodontal (gum) disease arrests the disease but does not usually regain the bone support or connective tissue lost in the disease process. Guided tissue regeneration (GTR) is a surgical procedure that specifically aims to regenerate the periodontal tissues when the disease is advanced and could overcome some of the limitations of conventional therapy. To assess the efficacy of GTR in the treatment of periodontal infra-bony defects measured against conventional surgery (open flap debridement (OFD)) and factors affecting outcomes. We conducted an electronic search of the Cochrane Oral Health Group Trials Register, MEDLINE and EMBASE up to April 2004. Handsearching included Journal of Periodontology, Journal of Clinical Periodontology, Journal of Periodontal Research and bibliographies of all relevant papers and review articles up to April 2004. In addition, we contacted experts/groups/companies involved in surgical research to find other trials or unpublished material or to clarify ambiguous or missing data and posted requests for data on two periodontal electronic discussion groups. Randomised, controlled trials (RCTs) of at least 12 months duration comparing guided tissue regeneration (with or without graft materials) with open flap debridement for the treatment of periodontal infra-bony defects. Furcation involvements and studies specifically treating aggressive periodontitis were excluded. Screening of possible studies and data extraction was conducted independently. The methodological quality of studies was assessed in duplicate using individual components and agreement determined by Kappa scores. Methodological quality was used in sensitivity analyses to test the robustness of the conclusions. The Cochrane Oral Health Group statistical guidelines were followed and the results expressed as mean differences (MD and 95% CI) for continuous outcomes and risk ratios (RR and 95% CI) for dichotomous outcomes calculated using

  11. A feasibility study on different NDT techniques used for testing bond quality in cold roll bonded Al-Sn alloy/steel bimetal strips

    Directory of Open Access Journals (Sweden)

    Tallafuss Philipp Johannes

    2017-01-01

    Full Text Available This paper presents non-destructive testing (NDT results for the detection of bond defects in aluminium-tin (Al-Sn alloy/steel bimetal strips. Among all types of bimetal strip that are used in the automotive industry for plain journal engine bearings, Al-Sn alloys cold roll bonded (CRB onto steel backing is the most common type. The difficulty to evaluate the metallurgical bond between the two dissimilar metals is a major industrial concern, which comprises the risk that bearings fail in the field. Considering the harsh performance requirements, 100% online non-destructive testing would be desirable to significantly reduce the business risk. Nowadays bimetal strip manufacturers still rely on destructive testing through different peel-off tests. This work offers the results from four independent NDT studies, using active thermography, shearography, ultrasound and guided wave electromagnetic acoustic transducers (EMATs and samples with different artificially implanted defects, to explore the feasibility to qualitatively indicate the occurrence of bond defects. A destructive peel off test was used to correlate the NDT results with known bond quality. The studies were done under laboratory conditions, and in case of ultrasound also online under production conditions. During the ultrasound online test, the requirements that a NDT technique has to fulfil for online inspection of Al-Sn alloy/steel bimetal strip were established. For active thermography, shearography and guided wave EMAT techniques, it was theoretically analysed, if the laboratory test results could be transferred to testing under production conditions. As a result, guided waves using EMATs, among the four tested methods, are best suited for online inspection of Al-Sn alloy/steel bimetal strip. This research was carried out in collaboration with MAHLE Engine Systems UK Ltd., an Al-Sn alloy/steel bimetal strip manufacturer for the automotive industry.

  12. Interstellar hydrogen bonding

    Science.gov (United States)

    Etim, Emmanuel E.; Gorai, Prasanta; Das, Ankan; Chakrabarti, Sandip K.; Arunan, Elangannan

    2018-06-01

    This paper reports the first extensive study of the existence and effects of interstellar hydrogen bonding. The reactions that occur on the surface of the interstellar dust grains are the dominant processes by which interstellar molecules are formed. Water molecules constitute about 70% of the interstellar ice. These water molecules serve as the platform for hydrogen bonding. High level quantum chemical simulations for the hydrogen bond interaction between 20 interstellar molecules (known and possible) and water are carried out using different ab-intio methods. It is evident that if the formation of these species is mainly governed by the ice phase reactions, there is a direct correlation between the binding energies of these complexes and the gas phase abundances of these interstellar molecules. Interstellar hydrogen bonding may cause lower gas abundance of the complex organic molecules (COMs) at the low temperature. From these results, ketenes whose less stable isomers that are more strongly bonded to the surface of the interstellar dust grains have been observed are proposed as suitable candidates for astronomical observations.

  13. An in vitro study to evaluate the effect of two ethanol-based and two acetone-based dental bonding agents on the bond strength of composite to enamel treated with 10% carbamide peroxide

    Directory of Open Access Journals (Sweden)

    Deepa Basavaraj Benni

    2014-01-01

    Full Text Available Background and Objective: Carbamide peroxide bleaching has been implicated in adversely affecting the bond strength of composite to enamel. The objective of this in vitro study was to evaluate the effect of ethanol-based (Clearfil S 3 bond, Kuraray, Adper Single bond 2, 3M ESPE dental products and acetone-based (Prime and Bond NT, Dentsply, One Step, Bisco bonding agents on the shear bond strength of composite to enamel treated with 10% carbamide peroxide bleaching agent. Materials and Methods: A total of 120 extracted human noncarious permanent incisors were randomly divided into two groups (control and experimental. Experimental group specimens were subjected to a bleaching regimen with a 10% carbamide peroxide bleaching system (Opalescence; Ultradent Products Inc, South Jordan, USA. Composite resin cylinders were bonded to the specimens using four bonding agents and shear bond strength was determined with universal testing machine. Results: There was no statistically significant difference in the shear bond strength between control and experimental groups with both ethanol-based (Clearfil S 3 Bond and Adper Single Bond 2 and acetone-based bonding agent (Prime and Bond NT and One Step. Interpretation and Conclusion: The adverse effect of bleaching on bonding composite to enamel can be reduced or eliminated by using either ethanol- or acetone-based bonding agent. Clinical Significances: Immediate bonding following bleaching procedure can be done using ethanol- or acetone-based bonding agent without compromising bond strength.

  14. Bone fragment union and remodeling after arthroscopic bony bankart repair for traumatic anterior shoulder instability with a glenoid defect: influence on postoperative recurrence of instability.

    Science.gov (United States)

    Nakagawa, Shigeto; Ozaki, Ritsuro; Take, Yasuhiro; Mae, Tatsuo; Hayashida, Kenji

    2015-06-01

    Although good clinical outcomes have been reported after arthroscopic bony Bankart repair, the extent of bone union is still unclear. To investigate bone union after arthroscopic bony Bankart repair and its influence on postoperative recurrence of instability. Cohort study; Level of evidence, 3. Among 113 consecutive shoulders that underwent arthroscopic bony Bankart repair, postoperative evaluation of bone union by computed tomography (CT) was performed at various times in 81 shoulders. Bone union was investigated during 3 periods: 3 to 6 months postoperatively (first period), 7 to 12 months postoperatively (second period), and 13 months or more postoperatively (third period). The influence of the size of the preoperative glenoid defect and the size of the bone fragment on bone union was investigated, as well as the influence of bone union on postoperative recurrence of instability. In shoulders with bone union, bone fragment remodeling and changes in the glenoid defect size were also investigated. The bone union rate was 30.5% in the first period, 55.3% in the second period, and 84.6% in the third period. Among 53 shoulders with CT evaluation in the second period or later and follow-up for a minimum of 1 year, there was complete union in 33 shoulders (62.3%), partial union in 3 (5.7%), nonunion in 8 (15.1%), and no fragment on CT in 9 (17.0%). The complete union rate was 50% for 22 shoulders with small bone fragments (fragments (5%-10%), and 86.7% for 15 shoulders with large fragments (>10%). The recurrence rate for postoperative instability was only 6.1% for shoulders with complete union, while it was 50% for shoulders with partial union, nonunion, no fragment, and no fragment on CT. The recurrence rate was significantly higher (36.4%) in shoulders with small fragments, but it was significantly lower in shoulders with bone union. In shoulders with bone union, the bone fragment frequently became larger over time, while the size of the glenoid defect decreased

  15. Studying Chemical Reactions, One Bond at a Time, with Single Molecule AFM Techniques

    Science.gov (United States)

    Fernandez, Julio M.

    2008-03-01

    The mechanisms by which mechanical forces regulate the kinetics of a chemical reaction are unknown. In my lecture I will demonstrate how we use single molecule force-clamp spectroscopy and protein engineering to study the effect of force on the kinetics of thiol/disulfide exchange. Reduction of disulfide bond via the thiol/disulfide exchange chemical reaction is crucial in regulating protein function and is of common occurrence in mechanically stressed proteins. While reduction is thought to proceed through a substitution nucleophilic bimolecular (SN2) reaction, the role of a mechanical force in modulating this chemical reaction is unknown. We apply a constant stretching force to single engineered disulfide bonds and measure their rate of reduction by dithiothreitol (DTT). We find that while the reduction rate is linearly dependent on the concentration of DTT, it is exponentially dependent on the applied force, increasing 10-fold over a 300 pN range. This result predicts that the disulfide bond lengthens by 0.34 å at the transition state of the thiol/disulfide exchange reaction. In addition to DTT, we also study the reduction of the engineered disulfide bond by the E. coli enzyme thioredoxin (Trx). Thioredoxins are enzymes that catalyze disulfide bond reduction in all organisms. As before, we apply a mechanical force in the range of 25-450 pN to the engineered disulfide bond substrate and monitor the reduction of these bonds by individual enzymes. In sharp contrast with the data obtained with DTT, we now observe two alternative forms of the catalytic reaction, the first requiring a reorientation of the substrate disulfide bond, causing a shortening of the substrate polypeptide by 0.76±0.07 å, and the second elongating the substrate disulfide bond by 0.21±0.01 å. These results support the view that the Trx active site regulates the geometry of the participating sulfur atoms, with sub-ångström precision, in order to achieve efficient catalysis. Single molecule

  16. Bonding polycarbonate brackets to ceramic: : Effects of substrate treatment on bond strength

    NARCIS (Netherlands)

    Özcan, Mutlu; Vallittu, Pekka K.; Peltomäki, Timo; Huysmans, Marie-Charlotte; Kalk, Warner

    2004-01-01

    This study evaluated the effects of 5 different surface conditioning methods on the bond strength of polycarbonate brackets bonded to ceramic surfaces with resin based cement. Six disc-shaped ceramic specimens (feldspathic porcelain) with glazed surfaces were used for each group. The specimens were

  17. Longevity of Self-etch Dentin Bonding Adhesives Compared to Etch-and-rinse Dentin Bonding Adhesives: A Systematic Review.

    Science.gov (United States)

    Masarwa, Nader; Mohamed, Ahmed; Abou-Rabii, Iyad; Abu Zaghlan, Rawan; Steier, Liviu

    2016-06-01

    A systematic review and meta-analysis were performed to compare longevity of Self-Etch Dentin Bonding Adhesives to Etch-and-Rinse Dentin Bonding Adhesives. The following databases were searched for PubMed, MEDLINE, Web of Science, CINAHL, the Cochrane Library complemented by a manual search of the Journal of Adhesive Dentistry. The MESH keywords used were: "etch and rinse," "total etch," "self-etch," "dentin bonding agent," "bond durability," and "bond degradation." Included were in-vitro experimental studies performed on human dental tissues of sound tooth structure origin. The examined Self-Etch Bonds were of two subtypes; Two Steps and One Step Self-Etch Bonds, while Etch-and-Rinse Bonds were of two subtypes; Two Steps and Three Steps. The included studies measured micro tensile bond strength (μTBs) to evaluate bond strength and possible longevity of both types of dental adhesives at different times. The selected studies depended on water storage as the aging technique. Statistical analysis was performed for outcome measurements compared at 24 h, 3 months, 6 months and 12 months of water storage. After 24 hours (p-value = 0.051), 3 months (p-value = 0.756), 6 months (p-value=0.267), 12 months (p-value=0.785) of water storage self-etch adhesives showed lower μTBs when compared to the etch-and-rinse adhesives, but the comparisons were statistically insignificant. In this study, longevity of Dentin Bonds was related to the measured μTBs. Although Etch-and-Rinse bonds showed higher values at all times, the meta-analysis found no difference in longevity of the two types of bonds at the examined aging times. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. SU-E-J-24: Image-Guidance Using Cone-Beam CT for Stereotactic Body Radiotherapy (SBRT) of Lung Cancer Patients: Bony Alignment or Soft Tissue Alignment?

    Science.gov (United States)

    Wang, L; Turaka, A; Meyer, J; Spoka, D; Jin, L; Fan, J; Ma, C

    2012-06-01

    To assess the reliability of soft tissue alignment by comparing pre- and post-treatment cone-beam CT (CBCT) for image guidance in stereotactic body radiotherapy (SBRT) of lung cancers. Our lung SBRT procedures require all patients undergo 4D CT scan in order to obtain patient-specific target motion information through reconstructed 4D data using the maximum-intensity projection (MIP) algorithm. The internal target volume (ITV) was outlined directly from the MIP images and a 3-5 mm margin expansion was then applied to the ITV to create the PTV. Conformal treatment planning was performed on the helical images, to which the MIP images were fused. Prior to each treatment, CBCT was used for image guidance by comparing with the simulation CT and for patient relocalization based on the bony anatomy. Any displacement of the patient bony structure would be considered as setup errors and would be corrected by couch shifts. Theoretically, as the PTV definition included target internal motion, no further shifts other than setup corrections should be made. However, it is our practice to have treating physicians further check target localization within the PTV. Whenever the shifts based on the soft-tissue alignment (that is, target alignment) exceeded a certain value (e.g. 5 mm), a post-treatment CBCT was carried out to ensure that the tissue alignment is reliable by comparing between pre- and post-treatment CBCT. Pre- and post-CBCT has been performed for 7 patients so far who had shifts beyond 5 mm despite bony alignment. For all patients, post CBCT confirmed that the visualized target position was kept in the same position as before treatment after adjusting for soft-tissue alignment. For the patient population studied, it is shown that soft-tissue alignment is necessary and reliable in the lung SBRT for individual cases. © 2012 American Association of Physicists in Medicine.

  19. Composite Bonding to Stainless Steel Crowns Using a New Universal Bonding and Single-Bottle Systems

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Hattan

    2013-01-01

    Full Text Available Aim. The aim of this study is to evaluate the shear bond strength of nanocomposite to stainless steel crowns using a new universal bonding system. Material and Methods. Eighty (80 stainless steel crowns (SSCs were divided into four groups (20 each. Packable nanocomposite was bonded to the lingual surface of the crowns in the following methods: Group A without adhesive (control group, Group B using a new universal adhesive system (Scotchbond Universal Adhesive, 3M ESPE, Seefeld, Germany, and Group C and Group D using two different brands of single-bottle adhesive systems. Shear bond strengths were calculated and the types of failure also were recorded. Results. The shear strength of Group B was significantly greater than that of other groups. No significant differences were found between the shear bond strengths of Groups C and D. The control group had significantly lower shear bond strength ( to composite than the groups that utilized bonding agents. Conclusion. Composites bonding to stainless steel crowns using the new universal bonding agent (Scotchbond Universal Adhesive, 3M ESPE, Seefeld, Germany show significantly greater shear bond strengths and fewer adhesive failures when compared to traditional single-bottle systems.

  20. Substituent Effects on the Stability of Thallium and Phosphorus Triple Bonds: A Density Functional Study.

    Science.gov (United States)

    Lu, Jia-Syun; Yang, Ming-Chung; Su, Ming-Der

    2017-07-05

    Three computational methods (M06-2X/Def2-TZVP, B3PW91/Def2-TZVP and B3LYP/LANL2DZ+dp) were used to study the effect of substitution on the potential energy surfaces of RTl≡PR (R = F, OH, H, CH₃, SiH₃, SiMe(Si t Bu₃)₂, Si i PrDis₂, Tbt (=C₆H₂-2,4,6-(CH(SiMe₃)₂)₃), and Ar* (=C₆H₃-2,6-(C₆H₂-2, 4,6- i -Pr₃)₂)). The theoretical results show that these triply bonded RTl≡PR compounds have a preference for a bent geometry (i.e., ∠R⎼Tl⎼P ≈ 180° and ∠Tl⎼P⎼R ≈ 120°). Two valence bond models are used to interpret the bonding character of the Tl≡P triple bond. One is model [I], which is best described as TlP. This interprets the bonding conditions for RTl≡PR molecules that feature small ligands. The other is model [II], which is best represented as TlP. This explains the bonding character of RTl≡PR molecules that feature large substituents. Irrespective of the types of substituents used for the RTl≡PR species, the theoretical investigations (based on the natural bond orbital, the natural resonance theory, and the charge decomposition analysis) demonstrate that their Tl≡P triple bonds are very weak. However, the theoretical results predict that only bulkier substituents greatly stabilize the triply bonded RTl≡PR species, from the kinetic viewpoint.

  1. Novel electrochemical approach to study corrosion mechanism of Al-Au wire-bond pad interconnections

    DEFF Research Database (Denmark)

    Elisseeva, O. V.; Bruhn, A.; Cerezo, J.

    2013-01-01

    A gold-aluminium material combination is typically employed as an interconnection for microelectronic devices. One of the reliability risks of such devices is that of corrosion of aluminium bond pads resulting from the galvanic coupling between an aluminium bond pad and a gold wire. The research...... presented in this manuscript focuses on studying bond pad corrosion by selecting an appropriate model system and a dedicated set of electrochemical and analytical experimental tools. Taking into account the complex three-dimensional structure and the small dimensions of Au-Al interconnections (around 50......-100 μm), a dedicated and novel experimental approach was developed. Au-Al covered silicon chips were developed under clean room conditions. Three-dimensional electrodes were mimicked as flat, two-dimensional bond pad model systems, allowing the use of microelectrochemical local probe techniques. Thin...

  2. Comparison of shear bond strength between unfilled resin to dry enamel and dentin bonding to moist and dry enamel

    Directory of Open Access Journals (Sweden)

    Yasini E.

    2005-05-01

    Full Text Available Statement of Problem: The use of dentine bondings on enamel and dentin in total etch protocols has recently become popular. Unfilled resin is hydrophobic and dentin bonding is hydrophilic in nature. This chemical difference could be effective in enamel bonding process. Purpose: The aim of this study was to compare the shear bond strength of unfilled resin to dry enamel and dentin bonding to dry and moist enamel. Materials and Methods: In this experimental study, a total of 30 incisor teeth were used. The specimens were randomly assigned to three groups of 10. 37% phosphoric acid etchant was applied to the enamel surfaces in each group for 15 seconds, rinsed with water for 20 seconds and dried for 20 seconds with compressed air in groups one and two. After conditioning, group 1 received unfilled resin (Margin Bond, Colten and group 2 received dentin bonding (Single Bond, 3M and in group 3 after conditioning and rinsing with water, a layer of dentin bonding (Single Bond was applied on wet enamel. The enamel and dentin bonding were light cured for 20 seconds. A ring mold 3.5 mm in diameter and 2 mm height was placed over the specimens to receive the composite filling material (Z100, 3M. The composite was cured for 40 seconds. The specimens were thermocycled and shear bond strengths were determined using an Instron Universal Testing Machine. The findings were analyzed by ANOVA One-Way and Tukey HSD tests. Results: Shear bond strength of dentin bonding to dry enamel was significantly less than unfilled resin to dry enamel (P<0.05. There was no significant difference between the bond strength of dentin bonding to moist and dry enamel. In addition bond strength of dentin bonding to wet enamel was not significantly different from unfilled resin to dry enamel. Conclusion: Based on the findings of this study, it is suggested that enamel surface should remain slightly moist after etching before bonding with single bond but when using unfilled resin, the

  3. Maternal bonding styles in smokers and non-smokers: a comparative study.

    Science.gov (United States)

    Csala, Iren; Elemery, Monika; Martinovszky, Fruzsina; Dome, Peter; Dome, Balazs; Faludi, Gabor; Sandor, Imola; Gyorffy, Zsuzsa; Birkas, Emma; Lazary, Judit

    2016-01-01

    Parental bonding has been implicated in smoking behavior, and the quality of maternal bonding (MB) has been associated with poor mental health and substance use. However, little is known about the association of MB and the smoking of the offspring. In our study, 129 smokers and 610 non-smoker medical students completed the parental bonding instrument, which measures MB along two dimensions: care and overprotection. Four categories can be created by high and low scores on care and overprotection: optimal parenting (OP; high care/low overprotection); affectionless control (ALC; low care/high overprotection); affectionate constraint (AC; high care/high overprotection), and neglectful parenting (NP; low care/low overprotection). Nicotine dependence was assessed by the Fagerstrom Nicotine Dependence Test, exhaled CO level, and daily cigarette consumption (CPD). Higher CPD was significantly associated with lower overprotection ( p  = 0.016) and higher care ( p  = 0.023) scores. The odds for being a smoker were significantly higher in the neglectful maternal bonding style compared to the other rearing styles ( p  = 0.022). Besides, smokers showed significantly higher care and lower overprotection scores with the Mann-Whitney U-test than non-smokers, although these associations did not remain significant in multiple regression models. Our results indicate that focusing on early life relationship between patient and mother can be important in psychotherapeutic interventions for smoking. Registration trials retrospectively registered.

  4. Structures and the Hydrogen Bonding Abilities of Estrogens Studied by Supersonic Jet/laser Spectroscopy

    Science.gov (United States)

    Morishima, Fumiya; Inokuchi, Yoshiya; Ebata, Takayuki

    2013-06-01

    Estrone, estradiol, estriol are known as endogenous estrogen which have the same steroidal frame with different substituent, leading to difference of physiological activity upon the formation of hydrogen bond with estrogen receptor. In the present study, structures of estrogens and their hydrated clusters in a supersonic jet have been studied by various laser spectroscopic techniques and density functional theory calculation to study how the difference of substituents affects their hydrogen bonding ability. Infrared spectra in the OH stretching region indicate a formation of intramolecular hydrogen-bond in estriol, which may lead to weaker physiological activity among the three estrogens. We also measured electronic and infrared spectra of 1:1 hydrated clusters of estrogen. The results show a switch of stable hydration site from the phenolic OH group to the five member ring by substituting one more OH group.

  5. Corrosion Study and Intermetallics Formation in Gold and Copper Wire Bonding in Microelectronics Packaging

    Directory of Open Access Journals (Sweden)

    Christopher Breach

    2013-07-01

    Full Text Available A comparison study on the reliability of gold (Au and copper (Cu wire bonding is conducted to determine their corrosion and oxidation behavior in different environmental conditions. The corrosion and oxidation behaviors of Au and Cu wire bonding are determined through soaking in sodium chloride (NaCl solution and high temperature storage (HTS at 175 °C, 200 °C and 225 °C. Galvanic corrosion is more intense in Cu wire bonding as compared to Au wire bonding in NaCl solution due to the minimal formation of intermetallics in the former. At all three HTS annealing temperatures, the rate of Cu-Al intermetallic formation is found to be three to five times slower than Au-Al intermetallics. The faster intermetallic growth rate and lower activation energy found in this work for both Au/Al and Cu/Al as compared to literature could be due to the thicker Al pad metallization which removed the rate-determining step in previous studies due to deficit in Al material.

  6. The extended variant of the bond valence-bond length correlation curve for boron(III)-oxygen bonds

    International Nuclear Information System (INIS)

    Sidey, Vasyl

    2015-01-01

    The extended variant of the bond valence (s)-bond length (r) correlation curve for boron(III)-oxygen bonds has been closely approximated using the three-parameter function s = [k/(r - l)] - m, where s is measured in valence units (vu), r is measured in Aa, k = 0.53 Aa.vu, l = 0.975(1) Aa and m = 0.32 vu. The function s = exp[(r 0 - r)/b] traditionally used in the modern bond valence model requires the separate set of the bond valence parameters (r 0 = 1.362 Aa; b = 0.23 Aa) in order to approximate the above s-r curve for the bonds shorter than ∝1.3 Aa.

  7. Blue-shifted and red-shifted hydrogen bonds: Theoretical study of the CH3CHO· · ·HNO complexes

    Science.gov (United States)

    Yang, Yong; Zhang, Weijun; Gao, Xiaoming

    The blue-shifted and red-shifted H-bonds have been studied in complexes CH3CHO?HNO. At the MP2/6-31G(d), MP2/6-31+G(d,p) MP2/6-311++G(d,p), B3LYP/6-31G(d), B3LYP/6-31+G(d,p) and B3LYP/6-311++G(d,p) levels, the geometric structures and vibrational frequencies of complexes CH3CHO?HNO are calculated by both standard and CP-corrected methods, respectively. Complex A exhibits simultaneously red-shifted C bond H?O and blue-shifted N bond H?O H-bonds. Complex B possesses simultaneously two blue-shifted H-bonds: C bond H?O and N bond H?O. From NBO analysis, it becomes evident that the red-shifted C bond H?O H-bond can be explained on the basis of the two opposite effects: hyperconjugation and rehybridization. The blue-shifted C bond H?O H-bond is a result of conjunct C bond H bond strengthening effects of the hyperconjugation and the rehybridization due to existence of the significant electron density redistribution effect. For the blue-shifted N bond H?O H-bonds, the hyperconjugation is inhibited due to existence of the electron density redistribution effect. The large blue shift of the N bond H stretching frequency is observed because the rehybridization dominates the hyperconjugation.

  8. Understanding Bonds - Denmark

    DEFF Research Database (Denmark)

    Rimmer, Nina Røhr

    2016-01-01

    Undervisningsmateriale. A bond is a debt security, similar to an ”I Owe You document” (IOU). When you purchase a bond, you are lending money to a government, municipality, corporation, federal agency or other entity known as the issuer. In return for the loan, the issuer promises to pay you...... a specified rate of interest during the life of the bond and to repay the face value of the bond (the principal) when it “matures,” or comes due. Among the types of bonds you can choose from are: Government securities, municipal bonds, corporate bonds, mortgage and asset-backed securities, federal agency...... securities and foreign government bonds....

  9. Chemical bonding in Tl cuprates studied by x-ray photoemission

    International Nuclear Information System (INIS)

    Vasquez, R.P.; Siegal, M.P.; Overmyer, D.L.; Ren, Z.F.; Lao, J.Y.; Wang, J.H.

    1999-01-01

    Epitaxial thin films of the Tl cuprate superconductors Tl 2 Ba 2 CaCu 2 O 8 , Tl 2 Ba 2 Ca 2 Cu 3 O 10 , and Tl 0.78 Bi 0.22 Ba 0.4 Sr 1.6 Ca 2 Cu 3 O 9-δ are studied with x-ray photoemission spectroscopy. These data, together with previous measurements in this lab of Tl 2 Ba 2 CuO 6+δ and TlBa 2 CaCu 2 O 7-δ , comprise a comprehensive data set for a comparative study of Tl cuprates with a range of chemical and electronic properties. In the Cu 2p spectra, a larger energy separation between the satellite and main peaks (E s -E m ) and a lower intensity ratio (I s /I m ) are found to correlate with higher values of T c . Analysis of these spectra within a simple configuration interaction model suggests that higher values of T c are related to low values of the O 2p→Cu 3d charge transfer energy. In the O 1s region, a smaller bond length between Ba and Cu-O planar oxygen is found to correlate with a lower binding energy for the signal associated with Cu-O bonding, most likely resulting from the increased polarization screening by Ba 2+ ions. For samples near optimum doping, maximum T c is observed to occur when the Tl 4f 7/2 binding energy is near 117.9 eV, which is near the middle of the range of values observed for Tl cuprates. Higher Tl 4f 7/2 binding energies, corresponding to formal oxidation states nearer Tl 1+ , are also found to correlate with longer bond lengths between Ba and Tl-O planar oxygen, and with higher binding energies of the O 1s signal associated with Tl-O bonding. copyright 1999 The American Physical Society

  10. The structure of betaxolol studied by infrared spectroscopy and natural bond orbital theory.

    Science.gov (United States)

    Canotilho, João; Castro, Ricardo A E

    2010-08-01

    Betaxolol is a selective beta(1) receptor blocker used in the treatment of hypertension and glaucoma. A study of the betaxolol structure based on infrared spectroscopy and natural bond orbital (NBO) theory is the main aim of the present research. FTIR spectra of the solid betaxolol were recorded in the region from 4000 to 400cm(-1), in the temperature range between 25 and -170 degrees C. For spectral interpretation, spectrum of the deuterated betaxolol and the theoretical vibrational spectra of the conformer present in the solid obtained at the B3LYP/6-31G* level of theory, were used. Further insight into the structure was provided by natural bond orbital theory. NBO analysis of the conformer, before and after optimization, was carried out at the same level of theory referred above. Vibrational modes involved in hydrogen bond in the stretching and bending region were used in the estimation of the enthalpy using empirical correlations between enthalpy and the frequency shift that occurs as a result of the establishment of intermolecular hydrogen bonds. A detailed study of the structure of betaxolol and of its intermolecular interactions was obtained from the combination spectroscopy and NBO theory. Copyright 2010 Elsevier B.V. All rights reserved.

  11. A Study on the Cost of Issuing Social Healthcare Corporation Bonds.

    Science.gov (United States)

    Fukunaga, Hajime; Yamauchi, Kazunobu

    2015-07-01

    The "Social Healthcare Corporation" system was established on 1 April 2007 as a result of the revised Japanese Medical Care Law. As of 1 October 2014, 234 corporations are certified Social Healthcare Corporations. These corporations are allowed to issue public bonds. However, to this day (1 December 2014), no bonds have been issued. In this paper, we focus on cost analysis with respect to issuing public bonds.

  12. The chemical bond in inorganic chemistry the bond valence model

    CERN Document Server

    Brown, I David

    2016-01-01

    The bond valence model is a version of the ionic model in which the chemical constraints are expressed in terms of localized chemical bonds formed by the valence charge of the atoms. Theorems derived from the properties of the electrostatic flux predict the rules obeyed by both ionic and covalent bonds. They make quantitative predictions of coordination number, crystal structure, bond lengths and bond angles. Bond stability depends on the matching of the bonding strengths of the atoms, while the conflicting requirements of chemistry and space lead to the structural instabilities responsible for the unusual physical properties displayed by some materials. The model has applications in many fields ranging from mineralogy to molecular biology.

  13. Evaluation of Shear Bond Strength of Orthodontic Brackets Bonded with Nano-Filled Composites

    OpenAIRE

    Chalipa, Javad; Akhondi, Mohammad Sadegh Ahmad; Arab, Sepideh; Kharrazifard, Mohammad Javad; Ahmadyar, Maryam

    2013-01-01

    Objectives: The purpose of this study was to evaluate the shear bond strength (SBS) of orthodontic brackets bonded with two types of nano-composites in comparison to a conventional orthodontic composite. Materials and Methods: Sixty extracted human first premolars were randomly divided into 3 groups each containing 20 teeth. In group I, a conventional orthodontic composite (Transbond XT) was used to bond the brackets, while two nano-composites (Filtek TM Supreme XT and AELITE Aesthetic Enamel...

  14. Effect of miscarriage history on maternal-infant bonding during the first year postpartum in the first baby study: a longitudinal cohort study.

    Science.gov (United States)

    Bicking Kinsey, Cara; Baptiste-Roberts, Kesha; Zhu, Junjia; Kjerulff, Kristen H

    2014-07-15

    Miscarriage, the unexpected loss of pregnancy before 20 weeks gestation, may have a negative effect on a mother's perception of herself as a capable woman and on her emotional health when she is pregnant again subsequent to the miscarriage. As such, a mother with a history of miscarriage may be at greater risk for difficulties navigating the process of becoming a mother and achieving positive maternal-infant bonding with an infant born subsequent to the loss. The aim of this study was to examine the effect of miscarriage history on maternal-infant bonding after the birth of a healthy infant to test the hypothesis that women with a history of miscarriage have decreased maternal-infant bonding compared to women without a history of miscarriage. We completed secondary analysis of the First Baby Study, a longitudinal cohort study, to examine the effect of a history of miscarriage on maternal-infant bonding at 1 month, 6 months, and 12 months after women experienced the birth of their first live-born baby. In a sample of 2798 women living in Pennsylvania, USA, we tested our hypothesis using linear regression analysis of Shortened Postpartum Bonding Questionnaire (S-PBQ) scores, followed by longitudinal analysis using a generalized estimating equations model with repeated measures. We found that women with a history of miscarriage had similar S-PBQ scores as women without a history of miscarriage at each of the three postpartum time points. Likewise, longitudinal analysis revealed no difference in the pattern of maternal-infant bonding scores between women with and without a history of miscarriage. Women in the First Baby Study with a history of miscarriage did not differ from women without a history of miscarriage in their reported level of bonding with their subsequently born infants. It is important for clinicians to recognize that even though some women may experience impaired bonding related to a history of miscarriage, the majority of women form a healthy bond

  15. Tin-Silver Alloys for Flip-Chip Bonding Studied with a Rotating Cylinder Electrode

    DEFF Research Database (Denmark)

    Tang, Peter Torben; Pedersen, E.H.; Bech-Nielsen, G.

    1999-01-01

    Electrodeposition of solder for flip-chip bonding is studied in the form of a pyrophosphate/iodide tin-silver alloy bath. The objective is to obtain a uniform alloy composition, with 3.8 At.% silver, over a larger area. This specific alloy will provide an eutectic solder melting at 221°C (or 10°C...... photoresist, have shown a stable and promising alternative to pure tin and tin-lead alloys for flip-chip bonding applications....

  16. Tensile Bond Strength of Metal Bracket Bonding to Glazed Ceramic Surfaces With Different Surface Conditionings

    Directory of Open Access Journals (Sweden)

    M. Imani

    2011-12-01

    Full Text Available Objective: The objective of this study was to compare the tensile bond strength of metal brackets bonding to glazed ceramic surfaces using three various surface treatments.Materials and Methods: Forty two glazed ceramic disks were assigned to three groups. In the first and second groups the specimens were etched with 9.5% hydrofluoric acid (HFA. Subsequently in first group, ceramic primer and adhesive were applied, but in second group a bonding agent alone was used. In third group, specimens were treated with 35% phosphoric acid followed by ceramic primerand adhesive application. Brackets were bonded with light cure composites. The specimens were stored in distilled water in the room temperature for 24 hours and thermocycled 500 times between 5°C and 55°C. The universal testing machine was used to test the tensile bond strength and the adhesive remenant index scores between three groups was evaluated. The data were subjected to one-way ANOVA, Tukey and Kruskal-Wallis tests respectively.Results: The tensile bond strength was 3.69±0.52 MPa forfirst group, 2.69±0.91 MPa for second group and 3.60±0.41 MPa for third group. Group II specimens showed tensile strength values significantly different from other groups (P<0.01.Conclusion: In spite of limitations in laboratory studies it may be concluded that in application of Scotch bond multipurpose plus adhesive, phosphoric acid can be used instead of HFA for bonding brackets to the glazed ceramic restorations with enough tensile bond strength.

  17. Composite bonding to stainless steel crowns using a new universal bonding and single-bottle systems.

    Science.gov (United States)

    Hattan, Mohammad Ali; Pani, Sharat Chandra; Alomari, Mohammad

    2013-01-01

    Aim. The aim of this study is to evaluate the shear bond strength of nanocomposite to stainless steel crowns using a new universal bonding system. Material and Methods. Eighty (80) stainless steel crowns (SSCs) were divided into four groups (20 each). Packable nanocomposite was bonded to the lingual surface of the crowns in the following methods: Group A without adhesive (control group), Group B using a new universal adhesive system (Scotchbond Universal Adhesive, 3M ESPE, Seefeld, Germany), and Group C and Group D using two different brands of single-bottle adhesive systems. Shear bond strengths were calculated and the types of failure also were recorded. Results. The shear strength of Group B was significantly greater than that of other groups. No significant differences were found between the shear bond strengths of Groups C and D. The control group had significantly lower shear bond strength (P universal bonding agent (Scotchbond Universal Adhesive, 3M ESPE, Seefeld, Germany) show significantly greater shear bond strengths and fewer adhesive failures when compared to traditional single-bottle systems.

  18. Shear Bond Strength of Orthodontic Brackets Bonded to Zirconium Crowns.

    Science.gov (United States)

    Mehmeti, Blerim; Azizi, Bleron; Kelmendi, Jeta; Iljazi-Shahiqi, Donika; Alar, Željko; Anić-Milošević, Sandra

    2017-06-01

    An increasing demand for esthetic restorations has resulted in an increased use of all-ceramic restorations, such as zirconium. However, one of the challenges the orthodontist must be willing to face is how to increase bond strength between the brackets and various ceramic restorations.Bond strength can beaffected bybracket type, by the material that bracketsaremade of, and their base surface design or retention mode. ​: A im: of this study was to perform a comparative analysis of the shear bond strength (SBS) of metallic and ceramic orthodontic brackets bonded to all-zirconium ceramic surfaces used for prosthetic restorations, and also to evaluate the fracture mode of these two types of orthodontic brackets. Twenty samples/semi-crowns of all-zirconium ceramic, on which orthodontic brackets were bonded, 10 metallic and 10 ceramic polycrystalline brackets, were prepared for this research. SBS has been testedby Universal Testing Machine, with a load applied using a knife edged rod moving at a fixed rate of 1 mm/min, until failure occurred. The force required to debond the brackets was recorded in Newton, then SBS was calculated to MPa. In addition, the samples were analyzed using a digital camera magnifier to determine Adhesive Remnant Index (ARI). Statistical data were processed using t-test, and the level of significance was set at α = 0.05. Higher shear bond strength values were observed in metallic brackets bonded to zirconium crowns compared tothoseof ceramic brackets, with a significant difference. During the test, two of the ceramic brackets were partially or totally damaged. Metallic brackets, compared to ceramic polycrystalline brackets, seemed tocreate stronger adhesion with all-zirconium surfaces due to their better retention mode. Also, ceramic brackets showed higher fragility during debonding.

  19. In vitro Comparative Evaluation of Tensile Bond Strength of 6(th), 7(th) and 8(th) Generation Dentin Bonding Agents.

    Science.gov (United States)

    Kamble, Suresh S; Kandasamy, Baburajan; Thillaigovindan, Ranjani; Goyal, Nitin Kumar; Talukdar, Pratim; Seal, Mukut

    2015-05-01

    Newer dentin bonding agents were developed to improve the quality of composite restoration and to reduce time consumption in its application. The aim of the present study was to evaluate tensile bond strength of 6(th), 7(th) and 8(th) generation bonding agents by in vitro method. Selected 60 permanent teeth were assigned into 20 in each group (Group I: 6(th) generation bonding agent-Adper SE plus 3M ESPE, Group II: 7(th) generation bonding agent-G-Bond GC Corp Japan and Group III: 8(th) generation dentin adhesives-FuturaBond, DC, Voco, Germany). With high-speed diamond disc, coronal dentin was exposed, and selected dentin bonding agents were applied, followed by composite restoration. All samples were saved in saline for 24 h and tensile bond strength testing was done using a universal testing machine. The obtained data were tabulated and statistically analyzed using ANOVA test. The tensile bond strength readings for 6(th) generation bonding agent was 32.2465, for 7(th) generation was 31.6734, and for 8(th)-generation dentine bonding agent was 34.74431. The highest tensile bond strength was seen in 8(th) generation bonding agent compared to 6(th) and 7(th) generation bonding agents. From the present study it can be conclude that 8(th) generation dentine adhesive (Futura DC, Voco, Germany) resulted in highest tensile bond strength compared to 6(th) (Adper SE plus, 3M ESPE) and 7(th) generation (G-Bond) dentin bonding agents.

  20. Sol-gel bonding of silicon wafers

    International Nuclear Information System (INIS)

    Barbe, C.J.; Cassidy, D.J.; Triani, G.; Latella, B.A.; Mitchell, D.R.G.; Finnie, K.S.; Bartlett, J.R.; Woolfrey, J.L.; Collins, G.A.

    2005-01-01

    Low temperature bonding of silicon wafers was achieved using sol-gel technology. The initial sol-gel chemistry of the coating solution was found to influence the mechanical properties of the resulting bonds. More precisely, the influence of parameters such as the alkoxide concentration, water-to-alkoxide molar ratio, pH, and solution aging on the final bond morphologies and interfacial fracture energy was studied. The thickness and density of the sol-gel coating were characterised using ellipsometry. The corresponding bonded specimens were investigated using attenuated total reflectance Fourier transformed infrared spectroscopy to monitor their chemical composition, infrared imaging to control bond integrity, and cross-sectional transmission electron microscopy to study their microstructure. Their interfacial fracture energy was measured using microindentation. An optimum water-to-alkoxide molar ratio of 10 and hydrolysis water at pH = 2 were found. Such conditions led to relatively dense films (> 90%), resulting in bonds with a fracture energy of 3.5 J/m 2 , significantly higher than those obtained using classical hydrophilic bonding (typically 1.5-2.5 J/m 2 ). Ageing of the coating solution was found to decrease the bond strength

  1. Density functional study of the bonding in small silicon clusters

    International Nuclear Information System (INIS)

    Fournier, R.; Sinnott, S.B.; DePristo, A.E.

    1992-01-01

    We report the ground electronic state, equilibrium geometry, vibrational frequencies, and binding energy for various isomers of Si n (n = 2--8) obtained with the linear combination of atomic orbitals-density functional method. We used both a local density approximation approach and one with gradient corrections. Our local density approximation results concerning the relative stability of electronic states and isomers are in agreement with Hartree--Fock and Moller--Plesset (MP2) calculations [K. Raghavachari and C. M. Rohlfing, J. Chem. Phys. 89, 2219 (1988)]. The binding energies calculated with the gradient corrected functional are in good agreement with experiment (Si 2 and Si 3 ) and with the best theoretical estimates. Our analysis of the bonding reveals two limiting modes of bonding and classes of silicon clusters. One class of clusters is characterized by relatively large s atomic populations and a large number of weak bonds, while the other class of clusters is characterized by relatively small s atomic populations and a small number of strong bonds

  2. The adsorption of acrolein on a Pt (1 1 1): A study of chemical bonding and electronic structure

    International Nuclear Information System (INIS)

    Pirillo, S.; López-Corral, I.; Germán, E.; Juan, A.

    2012-01-01

    Highlights: ► Study of acrolein/Pt (1 1 1) adsorption using ab-initio and semiempirical methods. ► Geometry optimization and DOS curves were carried out using VASP code. ► Study of chemical bonding evolution using COOP and OP analysis. ► After adsorption Pt-Pt, C=O and C=C bonds are weakened. ► η 3 -cis and η 4 -trans most stable adsorption modes, η 1 -trans less favored one. - Abstract: The adsorption of acrolein on a Pt (1 1 1) surface was studied using ab-initio and semiempirical calculations. Geometry optimization and densities of states (DOS) curves were carried out using the Vienna Ab-initio Simulation Package (VASP) code. We started our study with the preferential geometries corresponding to the different acrolein/Pt (1 1 1) adsorption modes previously reported. Then, we examined the evolution of the chemical bonding in these geometries, using the crystal orbital overlap population (COOP) and overlap population (OP) analysis of selected pairs of atoms. We analyzed the acrolein intramolecular bonds, Pt (1 1 1) superficial bonds and new molecule-surface formed bonds after adsorption. We found that Pt-Pt bonds interacting with the molecule and acrolein C=O and C=C bonds are weakened after adsorption; this last bond is significantly linked to the surface. The obtained C-Pt and O-Pt OP values suggest that the most stable adsorption modes are η 3 -cis and η 4 -trans, while the η 1 -trans is the less favored configuration. We also found that C p z orbital and Pt p z and d z 2 orbitals participate strongly in the adsorption process.

  3. Empirical Studies on Financial Markets: Private Equity, Corporate Bonds and Emerging Markets

    NARCIS (Netherlands)

    G.J. de Zwart (Gerben)

    2008-01-01

    textabstractThis dissertation consists of five empirical studies on financial markets. Each study can be read independently and covers a specific market, either private equity, corporate bonds or emerging markets. The first study documents that risk factors cannot account for the significant excess

  4. [Differential study of the bonding characterization of dental porcelain to Ni-Cr alloys].

    Science.gov (United States)

    Wei, Fang; Zhan, De-song; Wang, Yan-yan

    2008-10-01

    To study the bonding capability when Ni-Cr porcelain alloy was added with Ti, compound rare earth metals and removed the element of Be. Ni-Cr-Ti porcelain alloys manufactured by Institute of Metal Research of Chinese Academy of Sciences were tested. The test alloys were divided into three groups according to whether containing Be and compound rare earth metals or not. And HI BOND Ni-Cr base-metal alloy was chosen as control. The metal-ceramic specimens were prepared for shear test, scanning electron microscope (SEM) and energy spectrum analysis. The shear bond strength of the four groups were analyzed. No significant difference were observed among them (P > 0.05). No crackle was found and they were contacted tightly between the porcelain and metal. The composition and contents of the four groups' interfaces were closed. The shear bond strength of the self-made Ni-Cr-Ti porcelain alloys all can satisfy the clinical requirements. Experimental groups containing Ti, compound rare earth metals and removing the element of Be can be used as better recommendation for clinical practice.

  5. Peptide bond detection via graphene nanogaps: a proof of principle study.

    Science.gov (United States)

    Rossini, Aldo Eugenio; Gala, Fabrizio; Chinappi, Mauro; Zollo, Giuseppe

    2018-03-29

    Solid-state nanopores and nanogaps are emerging as promising tools for single molecule analysis. 2D materials, such as graphene, can potentially reach the spatial resolution needed for nucleic acid and protein sequencing. In the context of the density functional theory, atomistic modeling and non-equilibrium Green's function calculation, we show that glycine based polypeptide chains translocating across a nano-gap between two semi-infinite graphene nano-ribbons leave a specific transverse current signature for each peptide bond. The projected density of states and bond current analyses reveal a complex scenario with a role played by the adjacent α-carbons and side chains and by the orbitals of the partially resonant double bond involving C, N and O atoms of the peptide bond. In this context, specific fingerprints of the atoms involved in the peptide bonds are found. The same scenario is evidenced also for peptides involving alanine residues. The signal measured can be considered as a specific fingerprint of peptide bonds between small and neutral amino acids with no polar/charge effects. On this basis, a newly conceived nano-device made of a graphene based array of nano-gap is proposed as a possible route to approach peptide sequencing with atomic resolution.

  6. Preliminary Study on Hot Isostatic Pressing Diffusion Bonding for CLAM Steel

    International Nuclear Information System (INIS)

    Chunjing Li; Qunying Huang; Yican Wu

    2006-01-01

    China Low Activation Martensitic (CLAM) steel is being developed in ASIPP (Institute of Plasma Physics, Chinese Academy of Sciences) since three years ago. CLAM is selected as the major candidate structure materials for the FDS series design of fusion reactors and for China liquid metal LiPb Test Blanket Module (TBM) for ITER i.e. DFLL-TBM, which are being carried out in ASIPP. Since the hot isostatic pressing (HIP) bonding technique is one of the main candidate bonding techniques for manufacturing of the first wall of a fusion reactor, research of the HIP technique on CLAM/CLAM is greatly needed. Preliminary HIP diffusion bonding experiments on CLAM steel have been performed. A few machining approaches such as dry-milling, turnery and grounding etc. were used to prepare the sample surfaces and then they were degreased with a mixture of alcohol, ether and acetone in an ultrasonic bath. The samples were joined by HIP diffusion bonding with the compression pressure of 150 MPa and the holding time of 2 ∼ 3 hours under different temperatures between 950 deg. and 1100 deg.. Different seal techniques of the capsules were studied as well. Then appropriate post heat treatment was done. Tests on mechanical properties of the joints such as tensile strength and impact toughness have been performed. The preliminary results show that the tensile properties are roughly the same as those of the base material. The absorbed energy of the joints at present is a little low and further research is needed to increase it. Microstructure of the joints was studied by optical microscope, SEM and TEM. Compositions of the defects on the joining line were analyzed by EDS. Through analysis of the results, optimized parameters for HIP are given. (author)

  7. Endocrine and Local IGF-I in the Bony Fish Immune System.

    Science.gov (United States)

    Franz, Anne-Constance; Faass, Oliver; Köllner, Bernd; Shved, Natallia; Link, Karl; Casanova, Ayako; Wenger, Michael; D'Cotta, Helena; Baroiller, Jean-François; Ullrich, Oliver; Reinecke, Manfred; Eppler, Elisabeth

    2016-01-26

    A role for GH and IGF-I in the modulation of the immune system has been under discussion for decades. Generally, GH is considered a stimulator of innate immune parameters in mammals and teleost fish. The stimulatory effects in humans as well as in bony fish often appear to be correlated with elevated endocrine IGF-I (liver-derived), which has also been shown to be suppressed during infection in some studies. Nevertheless, data are still fragmentary. Some studies point to an important role of GH and IGF-I particularly during immune organ development and constitution. Even less is known about the potential relevance of local (autocrine/paracrine) IGF-I within adult and developing immune organs, and the distinct localization of IGF-I in immune cells and tissues of mammals and fish has not been systematically defined. Thus far, IGF-I has been localized in different mammalian immune cell types, particularly macrophages and granulocytes, and in supporting cells, but not in T-lymphocytes. In the present study, we detected IGF-I in phagocytic cells isolated from rainbow trout head kidney and, in contrast to some findings in mammals, in T-cells of a channel catfish cell line. Thus, although numerous analogies among mammals and teleosts exist not only for the GH/IGF-system, but also for the immune system, there are differences that should be further investigated. For instance, it is unclear whether the primarily reported role of GH/IGF-I in the innate immune response is due to the lack of studies focusing on the adaptive immune system, or whether it truly preferentially concerns innate immune parameters. Infectious challenges in combination with GH/IGF-I manipulations are another important topic that has not been sufficiently addressed to date, particularly with respect to developmental and environmental influences on fish growth and health.

  8. Endocrine and Local IGF-I in the Bony Fish Immune System

    Directory of Open Access Journals (Sweden)

    Anne-Constance Franz

    2016-01-01

    Full Text Available A role for GH and IGF-I in the modulation of the immune system has been under discussion for decades. Generally, GH is considered a stimulator of innate immune parameters in mammals and teleost fish. The stimulatory effects in humans as well as in bony fish often appear to be correlated with elevated endocrine IGF-I (liver-derived, which has also been shown to be suppressed during infection in some studies. Nevertheless, data are still fragmentary. Some studies point to an important role of GH and IGF-I particularly during immune organ development and constitution. Even less is known about the potential relevance of local (autocrine/paracrine IGF-I within adult and developing immune organs, and the distinct localization of IGF-I in immune cells and tissues of mammals and fish has not been systematically defined. Thus far, IGF-I has been localized in different mammalian immune cell types, particularly macrophages and granulocytes, and in supporting cells, but not in T-lymphocytes. In the present study, we detected IGF-I in phagocytic cells isolated from rainbow trout head kidney and, in contrast to some findings in mammals, in T-cells of a channel catfish cell line. Thus, although numerous analogies among mammals and teleosts exist not only for the GH/IGF-system, but also for the immune system, there are differences that should be further investigated. For instance, it is unclear whether the primarily reported role of GH/IGF-I in the innate immune response is due to the lack of studies focusing on the adaptive immune system, or whether it truly preferentially concerns innate immune parameters. Infectious challenges in combination with GH/IGF-I manipulations are another important topic that has not been sufficiently addressed to date, particularly with respect to developmental and environmental influences on fish growth and health.

  9. Convertible bond valuation focusing on Chinese convertible bond market

    OpenAIRE

    Yang, Ke

    2010-01-01

    This paper mainly discusses the methods of valuation of convertible bonds in Chinese market. Different from common convertible bonds in European market, considering the complicate features of Chinese convertible bond, this paper represents specific pricing approaches for pricing convertible bonds with different provisions along with the increment of complexity of these provisions. More specifically, this paper represents the decomposing method and binomial tree method for pricing both of Non-...

  10. LED Die-Bonded on the Ag/Cu Substrate by a Sn-BiZn-Sn Bonding System

    Science.gov (United States)

    Tang, Y. K.; Hsu, Y. C.; Lin, E. J.; Hu, Y. J.; Liu, C. Y.

    2016-12-01

    In this study, light emitting diode (LED) chips were die-bonded on a Ag/Cu substrate by a Sn-BixZn-Sn bonding system. A high die-bonding strength is successfully achieved by using a Sn-BixZn-Sn ternary system. At the bonding interface, there is observed a Bi-segregation phenomenon. This Bi-segregation phenomenon solves the problems of the brittle layer-type Bi at the joint interface. Our shear test results show that the bonding interface with Bi-segregation enhances the shear strength of the LED die-bonding joints. The Bi-0.3Zn and Bi-0.5Zn die-bonding cases have the best shear strength among all die-bonding systems. In addition, we investigate the atomic depth profile of the deposited Bi-xZn layer by evaporating Bi-xZn E-gun alloy sources. The initial Zn content of the deposited Bi-Zn alloy layers are much higher than the average Zn content in the deposited Bi-Zn layers.

  11. An Ab Initio MP2 Study of HCN-HX Hydrogen Bonded Complexes

    Directory of Open Access Journals (Sweden)

    Araújo Regiane C.M.U.

    1998-01-01

    Full Text Available An ab initio MP2/6-311++G** study has been performed to obtain geometries, binding energies and vibrational properties of HCN-HX H-bonded complexes with X = F, Cl, NC, CN and CCH. These MP2/6-311++G** results have revealed that: (i the calculated H-bond lengths are in very good agreement with the experimental ones; (ii the H-bond strength is associated with the intermolecular charge transfer and follows the order: HCN-HNC ~ HCN-HF > HCN-HCl ~ HCN-HCN > HCN-HCCH; (iii BSSE correction introduces an average reduction of 2.4 kJ/mol on the MP2/6-311++G** binding energies, i.e. 11% of the uncorrected binding energy; (iv the calculated zero-point energies reduce the stability of these complexes and show a good agreement with the available experimental values; (v the H-X stretching frequency is shifted downward upon H-bond formation. This displacement is associated with the H-bond length; (vi The more pronounced effect on the infrared intensities occurs with the H-X stretching intensity. It is much enhanced after complexation due to the charge-flux term; (vii the calculated intermolecular stretching frequencies are in very good agreement with the experimental ones; and, finally, (viii the results obtained for the HCN-HX complexes follow the same profile as those found for the acetylene-HX series but, in the latter case, the effects on the properties of the free molecules due to complexation are less pronounced than those in HCN-HX.

  12. Transition from metal-ligand bonding to halogen bonding involving a metal as halogen acceptor a study of Cu, Ag, Au, Pt, and Hg complexes

    Science.gov (United States)

    Oliveira, Vytor; Cremer, Dieter

    2017-08-01

    Utilizing all-electron Dirac-exact relativistic calculations with the Normalized Elimination of the Small Component (NESC) method and the local vibrational mode approach, the transition from metal-halide to metal halogen bonding is determined for Au-complexes interacting with halogen-donors. The local stretching force constants of the metal-halogen interactions reveal a smooth transition from weak non-covalent halogen bonding to non-classical 3-center-4-electron bonding and finally covalent metal-halide bonding. The strongest halogen bonds are found for dialkylaurates interacting with Cl2 or FCl. Differing trends in the intrinsic halogen-metal bond strength, the binding energy, and the electrostatic potential are explained.

  13. A DFT study of cyclopropane adsorption on Pt(1 1 1). Electronic structure and bonding

    International Nuclear Information System (INIS)

    Germán, E.; López-Corral, I.; Pirillo, S.; Juan, A.; Brizuela, G.

    2014-01-01

    We have studied the adsorption of cyclopropane (c-C 3 H 6 ) on Pt(1 1 1) by means of the density functional theory (DFT). We have investigated the preferential adsorption geometry, considering different adsorption sites and bonding configurations for the molecular adsorbate. We have also computed the electronic structure and bonding interactions by means of density of states (DOS), crystal orbital overlap population (OPDOS), and overlap population (OP) analysis. Our results show a small preference for Bridge and Top adsorption sites with the cyclopropane ring parallel to the surface. Pt-C equilibrium distance is ∼3.5 Å and a weak bond is formed during adsorption. The main bonding interaction comes from the Pt-H overlap population. Pt 5p z orbitals play an important role in the bonding between c-C 3 H 6 and the surface. We have found that Van der Waals (vdW) corrections to the energies improve the adsorption values without changing the preferential site geometries.

  14. Comparison of Shear Bond Strength of RMGI and Composite Resin for Orthodontic Bracket Bonding

    Science.gov (United States)

    Yassaei, Soghra; Davari, Abdolrahim; Goldani Moghadam, Mahjobeh; Kamaei, Ahmad

    2014-01-01

    Objective: The aim of this study was to compare the shear bond strength (SBS) of resin modified glass ionomer (RMGI) and composite resin for bonding metal and ceramic brackets. Materials and Methods: Eighty-eight human premolars extracted for orthodontic purposes were divided into 4 groups (n=22). In groups 1 and 2, 22 metal and ceramic brackets were bonded using composite resin (Transbond XT), respectively. Twenty-two metal and ceramic brackets in groups 3 and 4, respectively were bonded using RMGI (Fuji Ortho LC, Japan). After photo polymerization, the teeth were stored in water and thermocycled (500 cycles between 5° and 55°). The SBS value of each sample was determined using a Universal Testing Machine. The amount of residual adhesive remaining on each tooth was evaluated under a stereomicroscope. Statistical analyses were done using two-way ANOVA. Results: RMGI bonded brackets had significantly lower SBS value compared to composite resin bonded groups. No statistically significant difference was observed between metal and ceramic brackets bonded with either the RMGI or composite resin. The comparison of the adhesive remnant index (ARI) scores between the groups indicated that the bracket failure mode was significantly different among groups (Porthodontic bonding purposes; however the provided SBS is still within the clinically acceptable range. PMID:25628663

  15. AVE bond index in the H-bond of the Watson-Crick pairs

    International Nuclear Information System (INIS)

    Giambiagi, M.; Giambiagi, M.S. de; Barroso Filho, W.

    1981-01-01

    The normal Watson-Crick base pairs are treated as super-molecules. The properties of the electronic distribution along the N-H...Y bonds are studied in an all-valence-electrons calculation, through a bond index formula devised for non-orthogonal basis. Eletronic density diagrams of the adenine-uracil base pair are analysed. (Auhor) [pt

  16. Theoretical investigation of compounds with triple bonds

    International Nuclear Information System (INIS)

    Devarajan, Deepa

    2011-01-01

    In this thesis, compounds with potential triple-bonding character involving the heavier main-group elements, Group 4 transition metals, and the actinides uranium and thorium were studied by using molecular quantum mechanics. The triple bonds are described in terms of the individual orbital contributions (σ, π parallel , and π perpendicular to ), involving electron-sharing covalent or donor-acceptor interactions between the orbitals of two atoms or fragments. Energy decomposition, natural bond orbital, and atoms in molecules analyses were used for the bonding analysis of the triple bonds. The results of this thesis suggest that the triple-bonding character between the heavier elements of the periodic table is important and worth further study and exploration.

  17. Bond strength of composite resin to enamel: assessment of two ethanol wet-bonding techniques.

    Directory of Open Access Journals (Sweden)

    Maryam Khoroushi

    2014-04-01

    Full Text Available Ethanol wet-bonding (EWB technique has been stated to decrease degradation of resin-dentin bond. This study evaluated the effect of two EWB techniques on composite resin-to-enamel bond strength.Silicon carbide papers were used to produce flat enamel surfaces on the buccal faces of forty-five molars. OptiBond FL (OFL adhesive was applied on enamel surfaces in three groups of 15 namely: Enamel surface and OFL (control;Protocol 1 of the EWB technique: absolute ethanol was applied to water-saturated acid-etched enamel surfaces for 1 minute before the application of ethanol-solvated hydrophobic adhesive resin of OFL 3 times;Protocol 2: progressive ethanol replacement; water was gradually removed from the enamel matrix using ascending ethanol concentrations before OFL application. Composite build-ups were made and the specimens were stored for 24 hours at 37°C and 100% relative humidity. Shear bond strength test was performed using a universal testing machine at 1 mm/min crosshead speed. Fracture patterns were evaluated microscopically. Data were analyzed with one-way ANOVA and Fisher's exact test (α=0.05.There were no significant differences in bond strength between the groups (P=0.73. However, regarding failure patterns, the highest cohesive enamel fractures were recorded in groups 2 and 3.In this study, although both methods of EWB did not influence immediate bond strength of composite resin to enamel, the majority of failure patterns occurred cohesively in enamel.

  18. Proton transfer in a short hydrogen bond caused by solvation shell fluctuations: an ab initio MD and NMR/UV study of an (OHO)(-) bonded system.

    Science.gov (United States)

    Pylaeva, Svetlana; Allolio, Christoph; Koeppe, Benjamin; Denisov, Gleb S; Limbach, Hans-Heinrich; Sebastiani, Daniel; Tolstoy, Peter M

    2015-02-14

    We present a joint experimental and quantum chemical study on the influence of solvent dynamics on the protonation equilibrium in a strongly hydrogen bonded phenol-acetate complex in CD2Cl2. Particular attention is given to the correlation of the proton position distribution with the internal conformation of the complex itself and with fluctuations of the aprotic solvent. Specifically, we have focused on a complex formed by 4-nitrophenol and tetraalkylammonium-acetate in CD2Cl2. Experimentally we have used combined low-temperature (1)H and (13)C NMR and UV-vis spectroscopy and showed that a very strong OHO hydrogen bond is formed with proton tautomerism (PhOH···(-)OAc and PhO(-)···HOAc forms, both strongly hydrogen bonded). Computationally, we have employed ab initio molecular dynamics (70 and 71 solvent molecules, with and without the presence of a counter-cation, respectively). We demonstrate that the relative motion of the counter-cation and the "free" carbonyl group of the acid plays the major role in the OHO bond geometry and causes proton "jumps", i.e. interconversion of PhOH···(-)OAc and PhO(-)···HOAc tautomers. Weak H-bonds between CH(CD) groups of the solvent and the oxygen atom of carbonyl stabilize the PhOH···(-)OAc type of structures. Breaking of CH···O bonds shifts the equilibrium towards PhO(-)···HOAc form.

  19. Copper wire bonding

    CERN Document Server

    Chauhan, Preeti S; Zhong, ZhaoWei; Pecht, Michael G

    2014-01-01

    This critical volume provides an in-depth presentation of copper wire bonding technologies, processes and equipment, along with the economic benefits and risks.  Due to the increasing cost of materials used to make electronic components, the electronics industry has been rapidly moving from high cost gold to significantly lower cost copper as a wire bonding material.  However, copper wire bonding has several process and reliability concerns due to its material properties.  Copper Wire Bonding book lays out the challenges involved in replacing gold with copper as a wire bond material, and includes the bonding process changes—bond force, electric flame off, current and ultrasonic energy optimization, and bonding tools and equipment changes for first and second bond formation.  In addition, the bond–pad metallurgies and the use of bare and palladium-coated copper wires on aluminum are presented, and gold, nickel and palladium surface finishes are discussed.  The book also discusses best practices and re...

  20. Single-crystal neutron diffraction studies of hydrogen-bonded systems: Two recent examples from IPNS

    Energy Technology Data Exchange (ETDEWEB)

    Koetzle, Thomas F. [IPNS Division, Argonne National Laboratory, Argonne, IL 60439 (United States)], E-mail: tkoetzle@anl.gov; Piccoli, Paula M.B.; Schultz, Arthur J. [IPNS Division, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2009-02-21

    Beginning with work in the 1950s at the first generation of research reactors, studies of hydrogen-bonded systems have been a prime application for single-crystal neutron diffraction. The range of systems studied was extended in the 1960s and 1970s, with the advent of high flux reactor sources, and beginning around 1980 studies at pulsed neutron sources have made increasingly important contributions. Recently at the Argonne Intense Pulsed Neutron Source (IPNS), working with collaborators, we completed two studies of hydrogen-bonded systems that will serve to illustrate topics of current interest. In the first study, on andrographolide, an active diterpenoid natural product, our neutron diffraction results definitively characterize the hydrogen-bonding interactions. The second IPNS study is on tetraacetylethane (TAE), a {beta}-diketone enol system with a very short, strong intramolecular O-H...O hydrogen bond. At IPNS, we have determined the neutron crystal structure of TAE at five temperatures between 20 and 298 K to investigate changes in the structure with temperature and to probe for disorder. Despite the successes illustrated by the two examples presented here and by many other studies, at present applications of single-crystal neutron diffraction continue to be extremely flux limited and constrained by the requirement for mm-size crystals for many problems. These limitations are being addressed through the realization of powerful instruments at a new generation of pulsed neutron sources, including in the USA the TOPAZ and MaNDi single-crystal diffractometers that are under development at the Spallation Neutron Source (SNS)

  1. Single-crystal neutron diffraction studies of hydrogen-bonded systems: Two recent examples from IPNS

    Science.gov (United States)

    Koetzle, Thomas F.; Piccoli, Paula M. B.; Schultz, Arthur J.

    2009-02-01

    Beginning with work in the 1950s at the first generation of research reactors, studies of hydrogen-bonded systems have been a prime application for single-crystal neutron diffraction. The range of systems studied was extended in the 1960s and 1970s, with the advent of high flux reactor sources, and beginning around 1980 studies at pulsed neutron sources have made increasingly important contributions. Recently at the Argonne Intense Pulsed Neutron Source (IPNS), working with collaborators, we completed two studies of hydrogen-bonded systems that will serve to illustrate topics of current interest. In the first study, on andrographolide, an active diterpenoid natural product, our neutron diffraction results definitively characterize the hydrogen-bonding interactions. The second IPNS study is on tetraacetylethane (TAE), a β-diketone enol system with a very short, strong intramolecular O-H⋯O hydrogen bond. At IPNS, we have determined the neutron crystal structure of TAE at five temperatures between 20 and 298 K to investigate changes in the structure with temperature and to probe for disorder. Despite the successes illustrated by the two examples presented here and by many other studies, at present applications of single-crystal neutron diffraction continue to be extremely flux limited and constrained by the requirement for mm-size crystals for many problems. These limitations are being addressed through the realization of powerful instruments at a new generation of pulsed neutron sources, including in the USA the TOPAZ and MaNDi single-crystal diffractometers that are under development at the Spallation Neutron Source (SNS).

  2. Single-crystal neutron diffraction studies of hydrogen-bonded systems: Two recent examples from IPNS

    International Nuclear Information System (INIS)

    Koetzle, Thomas F.; Piccoli, Paula M.B.; Schultz, Arthur J.

    2009-01-01

    Beginning with work in the 1950s at the first generation of research reactors, studies of hydrogen-bonded systems have been a prime application for single-crystal neutron diffraction. The range of systems studied was extended in the 1960s and 1970s, with the advent of high flux reactor sources, and beginning around 1980 studies at pulsed neutron sources have made increasingly important contributions. Recently at the Argonne Intense Pulsed Neutron Source (IPNS), working with collaborators, we completed two studies of hydrogen-bonded systems that will serve to illustrate topics of current interest. In the first study, on andrographolide, an active diterpenoid natural product, our neutron diffraction results definitively characterize the hydrogen-bonding interactions. The second IPNS study is on tetraacetylethane (TAE), a β-diketone enol system with a very short, strong intramolecular O-H...O hydrogen bond. At IPNS, we have determined the neutron crystal structure of TAE at five temperatures between 20 and 298 K to investigate changes in the structure with temperature and to probe for disorder. Despite the successes illustrated by the two examples presented here and by many other studies, at present applications of single-crystal neutron diffraction continue to be extremely flux limited and constrained by the requirement for mm-size crystals for many problems. These limitations are being addressed through the realization of powerful instruments at a new generation of pulsed neutron sources, including in the USA the TOPAZ and MaNDi single-crystal diffractometers that are under development at the Spallation Neutron Source (SNS).

  3. A study on the bonding residual thermal stress analysis of dissimilar materials using boundary element method

    International Nuclear Information System (INIS)

    Yi, Won; Yu, Yeong Chul; Jeong, Eui Seob; Lee, Chang Ho

    1995-01-01

    It is very important to evaluate the bonding residual thermal stress in dissimilar materials such as LSI package. In this study, the bonding residual thermal stress was calculated using the boundary element method, varing with the sub-element, geometry of specimen and adhesive thickness. The present results reveal a stress singularity at the edge of the interface, therefore the bonding strength of metal/resin interface can be estimated by taking into account it.

  4. Ab Initio Study of the Dynamical Si–O Bond Breaking Event in α-Quartz

    International Nuclear Information System (INIS)

    Su Rui; Zhang Hong; Han Wei; Chen Jun

    2015-01-01

    The Si–O bond breaking event in the α-quartz at the first triplet (T_1) excitation state is studied by using ab initio molecular dynamics (AIMD) and nudged elastic band calculations. A meta-stable non-bridging oxygen hole center and E′ center (NBOHC-E′) is observed in the AIMD which consists of a broken Si–O bond with a Si–O distance of 2.54 Å. By disallowing the re-bonding of the Si and O atoms, another defect configuration (III-Si/V-Si) is obtained and validated to be stable at both ground and excitation states. The NBOHC-E′ is found to present on the minimal energy pathway of the initial to III-Si/V-Si transition, showing that the generating of the NBOHC-E′ is an important step of the excitation induced structure defect. The energy barriers to produce the NBOHC-E′ and III-Si/V-Si defects are calculated to be 1.19 and 1.28 eV, respectively. The electronic structures of the two defects are calculated by the self-consistent GW calculations and the results show a clear electron transition from the bonding orbital to the non-bonding orbital. (paper)

  5. Factors affecting the shear bond strength of metal and ceramic brackets bonded to different ceramic surfaces.

    Science.gov (United States)

    Abu Alhaija, Elham S J; Abu AlReesh, Issam A; AlWahadni, Ahed M S

    2010-06-01

    The aims of this study were to evaluate the shear bond strength (SBS) of metal and ceramic brackets bonded to two different all-ceramic crowns, IPS Empress 2 and In-Ceram Alumina, to compare the SBS between hydrofluoric acid (HFA), phosphoric acid etched, and sandblasted, non-etched all-ceramic surfaces. Ninety-six all-ceramic crowns were fabricated resembling a maxillary left first premolar. The crowns were divided into eight groups: (1) metal brackets bonded to sandblasted 9.6 per cent HFA-etched IPS Empress 2 crowns; (2) metal brackets bonded to sandblasted 9.6 per cent HFA-etched In-Ceram crowns; (3) ceramic brackets bonded to sandblasted 9.6 per cent HFA-etched IPS Empress 2 crowns; (4) ceramic brackets bonded to sandblasted 9.6 per cent HFA-etched In-Ceram crowns; (5) metal brackets bonded to sandblasted 37 per cent phosphoric acid-etched IPS Empress 2 crowns; (6) metal brackets bonded to sandblasted 37 per cent phosphoric acid-etched In-Ceram crowns; (7) metal brackets bonded to sandblasted, non-etched IPS Empress 2 crowns; and (8) metal brackets bonded to sandblasted, non-etched In-Ceram crowns. Metal and ceramic orthodontic brackets were bonded using a conventional light polymerizing adhesive resin. An Instron universal testing machine was used to determine the SBS at a crosshead speed of 0.1 mm/minute. Comparison between groups was performed using a univariate general linear model and chi-squared tests. The highest mean SBS was found in group 3 (120.15 +/- 45.05 N) and the lowest in group 8 (57.86 +/- 26.20 N). Of all the variables studied, surface treatment was the only factor that significantly affected SBS (P Empress 2 and In-Ceram groups.

  6. Role of the bond defect for structural transformations between crystalline and amorphous silicon: A molecular-dynamics study

    International Nuclear Information System (INIS)

    Stock, D. M.; Weber, B.; Gaertner, K.

    2000-01-01

    The relation between the bond defect, which is a topological defect, and structural transformations between crystalline and amorphous silicon, is studied by molecular-dynamics simulations. The investigation of 1-keV boron implantation into crystalline silicon proves that the bond defect can also be generated directly by collisional-induced bond switching in addition to its formation by incomplete recombination of primary defects. This supports the assumption that the bond defect may play an important role in the amorphization process of silicon by light ions. The analysis of the interface between (001) silicon and amorphous silicon shows that there are two typical defect configurations at the interface which result from two different orientations of the bond defect with respect to the interface. Thus the bond defect appears to be a characteristic structural feature of the interface. Moreover, annealing results indicate that the bond defect acts as a growth site for interface-mediated crystallization

  7. Relationship between thin-film bond strength as measured by a scratch test, and indentation hardness for bonding agents.

    Science.gov (United States)

    Kusakabe, Shusuke; Rawls, H Ralph; Hotta, Masato

    2016-03-01

    To evaluate thin-film bond strength between a bonding agent and human dentin, using a scratch test, and the characteristics and accuracy of measurement. One-step bonding agents (BeautiBond; Bond Force; Adper Easy Bond; Clearfil tri-S Bond) and two-step bonding agents (Cleafil SE Bond; FL-Bond II) were investigated in this study. Flat dentin surfaces were prepared for extracted human molars. The dentin surfaces were ground and bonding agents were applied and light cured. The thin-film bond strength test of the specimens was evaluated by the critical load at which the coated bonding agent failed and dentin appeared. The scratch mark sections were then observed under a scanning electron microscope. Indentation hardness was evaluated by the variation in depth under an applied load of 10gf. Data were compared by one-way ANOVA with the Scheffé's post hoc multiple comparison test (pstrength and indentation hardness were analyzed using analysis of correlation and covariance. The thin-film bond strength of two-step bonding agents were found to be significantly higher than that of one-step bonding agents with small standard deviations. Scratch marks consistently showed adhesive failure in the vicinity of the bonding agent/dentin interface. The indentation hardness showed a trend that two-step bonding agents have greater hardness than one-step bonding agents. A moderately significant correlation (r(2)=0.31) was found between thin-film bond strength and indentation hardness. Thin-film bond strength test is a valid and reliable means of evaluating bond strength in the vicinity of the adhesive interface and is more accurate than other methods currently in use. Further, the thin-film bond strength is influenced by the hardness of the cued bonding agent. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  8. Computational study of the signature of hydrogen-bond strength on the infrared spectra of a hydrogen-bonded complex dissolved in a polar liquid

    International Nuclear Information System (INIS)

    Hanna, Gabriel; Geva, Eitan

    2010-01-01

    The signature of hydrogen-bond strength on the one- and two-dimensional infrared spectra of the hydrogen-stretch in a hydrogen-bonded complex dissolved in a polar liquid was investigated via mixed quantum-classical molecular dynamics simulations. Non-Condon effects were found to intensify with increasing hydrogen-bond strength and to shift oscillator strength from the stable configurations that correspond to the ionic and covalent tautomers into unstable configurations that correspond to the transition-state between them. The transition-state peak is observed to blue shift and increase in intensity with increasing hydrogen-bond strength, and to dominate the spectra in the case of a strong hydrogen-bond. It is argued that the application of multidimensional infrared spectroscopy in the region of the transition-state peak can provide a uniquely direct probe of the molecular events underlying breaking and forming of hydrogen-bonds in the condensed phase.

  9. Forensic age estimation by magnetic resonance imaging of the knee: the definite relevance in bony fusion of the distal femoral- and the proximal tibial epiphyses using closest-to-bone T1 TSE sequence

    Energy Technology Data Exchange (ETDEWEB)

    Ottow, Christian; Heindel, Walter [University Hospital Muenster, Department of Clinical Radiology, Muenster (Germany); Schulz, Ronald; Pfeiffer, Heidi; Schmeling, Andreas [University Hospital Muenster, Institute of Legal Medicine, Muenster (Germany); Vieth, Volker [University Hospital Muenster, Department of Clinical Radiology, Muenster (Germany); Klinikum Ibbenbueren, Clinic for Radiology, Ibbenbueren (Germany)

    2017-12-15

    To clarify the relevance of the bony fusion of the distal femoral and the proximal tibial epiphyses by means of magnetic resonance imaging (MRI), a prospective cross-sectional cohort study was performed with a special focus on a reliable determination of the 14th, 16th and 18th years of life. We scanned 658 German volunteers in the age bracket 12-24 years using a 3.0 T MR-scanner and utilising a T1 turbo spin-echo sequence representing true bone anatomy. Minimum, maximum, mean ± standard deviation and median with lower and upper quartiles were defined. Intra- and interobserver agreements were determined (Cohen's kappa). The statistical relevance of sex-related differences was analysed (Mann-Whitney U test, p < 0.05, exact, two-sided). The bony fusion took place before the 18th year of life in both epiphyses. The Mann-Whitney U test results imply significant sex-related differences for most stages. For both epiphyses, the intra observer (κ femur 0.961; tibia 0.971) and interobserver (κ femur 0.941; tibia 0.951) agreement levels were very good. The 14th and the 16th years of life can be determined in both sexes, but the completion of the 18th year of life cannot solely be determined by the bony fusion, as depicted by closest-to-bone MRI. (orig.)

  10. Forensic age estimation by magnetic resonance imaging of the knee: the definite relevance in bony fusion of the distal femoral- and the proximal tibial epiphyses using closest-to-bone T1 TSE sequence

    International Nuclear Information System (INIS)

    Ottow, Christian; Heindel, Walter; Schulz, Ronald; Pfeiffer, Heidi; Schmeling, Andreas; Vieth, Volker

    2017-01-01

    To clarify the relevance of the bony fusion of the distal femoral and the proximal tibial epiphyses by means of magnetic resonance imaging (MRI), a prospective cross-sectional cohort study was performed with a special focus on a reliable determination of the 14th, 16th and 18th years of life. We scanned 658 German volunteers in the age bracket 12-24 years using a 3.0 T MR-scanner and utilising a T1 turbo spin-echo sequence representing true bone anatomy. Minimum, maximum, mean ± standard deviation and median with lower and upper quartiles were defined. Intra- and interobserver agreements were determined (Cohen's kappa). The statistical relevance of sex-related differences was analysed (Mann-Whitney U test, p < 0.05, exact, two-sided). The bony fusion took place before the 18th year of life in both epiphyses. The Mann-Whitney U test results imply significant sex-related differences for most stages. For both epiphyses, the intra observer (κ femur 0.961; tibia 0.971) and interobserver (κ femur 0.941; tibia 0.951) agreement levels were very good. The 14th and the 16th years of life can be determined in both sexes, but the completion of the 18th year of life cannot solely be determined by the bony fusion, as depicted by closest-to-bone MRI. (orig.)

  11. Comparison of shear bond strength of amalgam bonded to primary and permanent dentin

    Directory of Open Access Journals (Sweden)

    Mahdi S

    2008-06-01

    Full Text Available Amalgam′s non-adhesive characteristics necessitate cavity preparations incorporating retentive features, which often require the removal of non-carious tooth structure. Use of adhesives beneath amalgam restorations, would be helpful to overcome this disadvantage. This study was undertaken to compare the mean shear bond strength of amalgam bonded to primary and permanent dentin, to evaluate the efficacy of amalgam adhesives in pediatric dentistry.27 primary and 28 permanent posterior teeth with intact buccal or lingual surfaces were grounded to expose dentin and wet-polished with 400-grit silicone carbide paper. Scotchbond Multi Purpose Plus adhesive system was applied to the dentin surfaces and light cured. Amalgam was condensed onto the treated dentin through a plastic mold.shear bond strength testing was done using an Instron Universal testing machine, at a crosshead speed of 0.5 mm/min.The data were analyzed by independent samples t-test The difference among the two groups was not statistically significant (p>0.05 Bonded amalgam showed the same level of bond strength to primary and permanent dentin; so, application of amalgam bonding agents in pediatric dentistry can be recommended.

  12. Effect of mode of polymerization of bonding agent on shear bond strength of autocured resin composite luting cements.

    Science.gov (United States)

    Dong, Cecilia C S; McComb, Dorothy; Anderson, James D; Tam, Laura E

    2003-04-01

    There have been anecdotal reports of low bond strength with autocured resin composite materials, particularly when light-cured bonding agents that combine primer and adhesive in a 1-bottle preparation are used. The objective of this study was to determine if the mode of polymerization of the bonding agent influences the strength of the attachment of autocured resin composite luting cements to dentin. The shear bond strength of 2 resin luting cements, Calibra and RelyX ARC, polymerized by autocuring, in combination with 4 different bonding agents, Scotchbond Multipurpose Plus, Prime & Bond NT, IntegraBond and Single Bond, polymerized to bovine dentin by light-curing, autocuring or dual-curing, was determined. The pH of each bonding agent and its components was measured. Two-way analysis of variance was used to test the effect of cement and adhesive on shear bond strength. For each bonding agent, the adhesive variable combined the factors product brand and mode of polymerization. With significant interaction among the above variables, the least square means of the 16 combinations of resin cement and adhesive were compared. There was no consistent relationship between shear bond strength and mode of polymerization of the bonding agent. Significant differences in bond strength were specific to the proprietary brand of bonding agent. The pH of the bonding agent depends on the manufacturer's formulation, and low pH may contribute to low bond strength. The low in vitro bond strength occurring with some combinations of bonding agent and resin cement could be clinically significant.

  13. Effect of Bonding Pressure and Bonding Time on the Tensile Properties of Cu-Foam / Cu-Plate Diffusion Bonded Joint

    International Nuclear Information System (INIS)

    Kim, Sang-Ho; Heo, Hoe-Jun; Kang, Chung-Yun; Yoon, Tae-Jin

    2016-01-01

    Open cell Cu foam, which has been widely utilized in various industries because of its high thermal conductivity, lightweight and large surface area, was successfully joined with Cu plate by diffusion bonding. To prevent excessive deformation of the Cu foam during bonding process, the bonding pressure should be lower than 500 kPa at 800 ℃ for 60 min and bonding pressure should be lowered with increasing holding time. The bonding strength was evaluated by tensile tests. The tensile load of joints increased with the bonding pressure and holding time. In the case of higher bonding pressure or time, the bonded length at the interface was usually longer than the cross-sectional length of the foam, so fracture occurred at the foam. For the same reason, base metal (foam) fracture mainly occurred at the node-plate junction rather than in the strut-plate junction because the bonded surface area of the node was relatively larger than that of the strut.

  14. Effect of various commercially available mouthrinses on shear bond strength of orthodontic metal brackets: an in vitro study.

    Science.gov (United States)

    Meeran, Nazeer Ahmed; George, Ashwin Mathew

    2013-01-01

    Alcohol is known to degrade and dissolve the bisphenol A glycidyl methacrylate present in the composite resin. The effect of alcohol containing mouthrinses on the shear bond strength of orthodontic metal brackets bonded with composite resin has not been verified until date and is the purpose of this study. The aims and objectives of the present study were to evaluate (1) Whether there is a significant difference in the shear bond strength of metal orthodontic brackets after the 1 year (12 h) and 2 years simulation (24 h) of mouth rinsing with 4 different commercially available mouthrinses (2 alcoholic and 2 alcohol-free mouthrinses) when compared to the control. (2) Whether alcohol containing mouthrinses have more adverse effect on the shear bond strength when compared with alcohol-free mouthrinses. (3) To assess the site of bond failure using adhesive remnant index. Experimental - laboratory based. A total of 100 upper premolars extracted for orthodontic purpose were collected immediately after extraction, cleared soft-tissue debris and blood and immediately stored in distilled water with 0.1% thymol crystals added to inhibit bacterial growth. Two alcohol containing mouthrinses and two alcohol-free mouthrinses were used and the bonded teeth were placed in the mouthrinses for a stipulated period of time (1 year simulation and 2 years simulation) and shear bond strength were tested using Lloyd Universal Testing Machine. The data were analyzed using analysis of variance and paired samples t-test. After the 1 year and 2 years simulation time, samples stored in alcohol containing mouthrinses showed lower bond strength (P orthodontic brackets bonded with composite resin (Transbond XT in the present study), more when compared with alcohol-free mouthrinses. It is, therefore, highly advisable to avoid alcohol containing mouthrinses in patients undergoing orthodontic treatment and use alcohol-free mouthrinses as adjuncts to regular oral hygiene procedures for maintaining

  15. Bond Issues.

    Science.gov (United States)

    Pollack, Rachel H.

    2000-01-01

    Notes trends toward increased borrowing by colleges and universities and offers guidelines for institutions that are considering issuing bonds to raise money for capital projects. Discussion covers advantages of using bond financing, how use of bonds impacts on traditional fund raising, other cautions and concerns, and some troubling aspects of…

  16. Utilization of cone-beam CT for offline evaluation of target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment.

    Science.gov (United States)

    Paluska, Petr; Hanus, Josef; Sefrova, Jana; Rouskova, Lucie; Grepl, Jakub; Jansa, Jan; Kasaova, Linda; Hodek, Miroslav; Zouhar, Milan; Vosmik, Milan; Petera, Jiri

    2012-01-01

    To assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction. Implementation of IGRT should influence safety margins. Utilization of cone-beam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose distribution. Seventeen prostate patients were treated with daily bony anatomy image-guidance. Cone-beam CT (CBCT) scans were acquired once a week immediately after bony anatomy alignment. After the prostate, seminal vesicles, rectum and bladder were contoured, the delivered dose distribution was reconstructed. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed a 1 cm safety margin. Alternative plans assuming a smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with the initial ones. Rectal and bladder volumes irradiated with doses higher than 75 Gy, 70 Gy, 60 Gy, 50 Gy and 40 Gy were analyzed. In 12% of reconstructed plans the prostate coverage was not sufficient. The prostate underdosage was observed in 5 patients. Coverage of seminal vesicles was not satisfactory in 3% of plans. Most of the target underdosage corresponded to excessive rectal or bladder filling. Evaluation of alternative plans assuming a smaller 7 mm margin revealed 22% and 11% of plans where prostate and seminal vesicles coverage, respectively, was compromised. These were distributed over 8 and 7 patients, respectively. Sufficient dose coverage of target volumes was not achieved for all patients. Reducing of safety margin is not acceptable. Initial rectal and bladder volumes cannot be considered representative for subsequent treatment.

  17. Repair Bond Strength of Aged Resin Composite after Different Surface and Bonding Treatments

    Directory of Open Access Journals (Sweden)

    Michael Wendler

    2016-07-01

    Full Text Available The aim of this study was to compare the effect of different mechanical surface treatments and chemical bonding protocols on the tensile bond strength (TBS of aged composite. Bar specimens were produced using a nanohybrid resin composite and aged in distilled water for 30 days. Different surface treatments (diamond bur, phosphoric acid, silane, and sandblasting with Al2O3 or CoJet Sand, as well as bonding protocols (Primer/Adhesive were used prior to application of the repair composite. TBS of the specimens was measured and the results were analyzed using analysis of variance (ANOVA and the Student–Newman–Keuls test (α = 0.05. Mechanically treated surfaces were characterized under SEM and by profilometry. The effect of water aging on the degree of conversion was measured by means of FTIR-ATR spectroscopy. An important increase in the degree of conversion was observed after aging. No significant differences in TBS were observed among the mechanical surface treatments, despite variations in surface roughness profiles. Phosphoric acid etching significantly improved repair bond strength values. The cohesive TBS of the material was only reached using resin bonding agents. Application of an intermediate bonding system plays a key role in achieving reliable repair bond strengths, whereas the kind of mechanical surface treatment appears to play a secondary role.

  18. Shear Bond Strength of Three Orthodontic Bonding Systems on Enamel and Restorative Materials.

    Science.gov (United States)

    Hellak, Andreas; Ebeling, Jennifer; Schauseil, Michael; Stein, Steffen; Roggendorf, Matthias; Korbmacher-Steiner, Heike

    2016-01-01

    Objective. The aim of this in vitro study was to determine the shear bond strength (SBS) and adhesive remnant index (ARI) score of two self-etching no-mix adhesives (iBond ™ and Scotchbond ™ ) on different prosthetic surfaces and enamel, in comparison with the commonly used total etch system Transbond XT ™ . Materials and Methods . A total of 270 surfaces (1 enamel and 8 restorative surfaces, n = 30) were randomly divided into three adhesive groups. In group 1 (control) brackets were bonded with Transbond XT primer. In the experimental groups iBond adhesive (group 2) and Scotchbond Universal adhesive (group 3) were used. The SBS was measured using a Zwicki 1120 ™ testing machine. The ARI and SBS were compared statistically using the Kruskal-Wallis test ( P ≤ 0.05). Results . Significant differences in SBS and ARI were found between the control group and experimental groups. Conclusions . Transbond XT showed the highest SBS on human enamel. Scotchbond Universal on average provides the best bonding on all other types of surface (metal, composite, and porcelain), with no need for additional primers. It might therefore be helpful for simplifying bonding in orthodontic procedures on restorative materials in patients. If metal brackets have to be bonded to a metal surface, the use of a dual-curing resin is recommended.

  19. Crystal structure, vibrational spectra and DFT studies of hydrogen bonded 1,2,4-triazolium hydrogenselenate

    Science.gov (United States)

    Arjunan, V.; Thirunarayanan, S.; Marchewka, M. K.; Mohan, S.

    2017-10-01

    The new hydrogen bonded molecular complex 1,2,4-triazolium hydrogenselenate (THS) is prepared by the reaction of 1H-1,2,4-triazole and selenic acid. This complex is stabilised by N-H⋯O and C-H⋯O hydrogen bonding and electrostatic attractive forces between 1H and 1,2,4-triazolium cations and hydrogen selenate anions. The XRD studies revealed that intermolecular proton transfer occur from selenic acid to 1H-1,2,4-triazole molecule, results in the formation of 1,2,4-triazolium hydrogenselenate which contains 1,2,4-triazolium cations and hydrogenselenate anions. The molecular structure of THS crystal has also been optimised by using Density Functional Theory (DFT) using B3LYP/cc-pVTZ and B3LYP/6-311++G** methods in order to find the whole characteristics of the molecular complex. The theoretical structural parameters such as bond length, bond angle and dihedral angle determined by DFT methods are well agreed with the XRD parameters. The atomic charges and thermodynamic properties are also calculated and analysed. The energies of frontier molecular orbitals HOMO, LUMO, HOMO-1, LUMO+1 and LUMO-HUMO energy gap are calculated to understand the kinetic stability and chemical reactivity of the molecular complex. The natural bond orbital analysis (NBO) has been performed in order to study the intramolecular bonding interactions and delocalisation of electrons. These intra molecular charge transfer may induce biological activities such as antimicrobials, antiinflammatory, antifungal etc. The complete vibrational assignments of THS have been performed by using FT-IR and FT-Raman spectra.

  20. Chemical Bonding in Tl Cuprates Studied by X-Ray Photoemission

    Energy Technology Data Exchange (ETDEWEB)

    Lao, J.Y.; Overmyer, D.L.; Ren, Z.F.; Siegal, M.P.; Vasquez, R.P.; Wang, J.H.

    1999-04-05

    Epitaxial thin films of the Tl cuprate superconductors Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8}, Tl{sub 2}Ba{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10}, and TL{sub 0.78}Bi{sub 0.22}Ba{sub 0.4}Sr{sub 1.6}Ca{sub 2}Cu{sub 3}O{sub 9{minus}{delta}} are studied with x-ray photoemission spectroscopy. These data, together with previous measurements in this lab of Tl{sub 2}Ba{sub 2}CuO{sub 6+{delta}} and TlBa{sub 2}CaCu{sub 2}O{sub 7{minus}{delta}}, comprise a comprehensive data set for a comparative study of Tl cuprates with a range of chemical and electronic properties. In the Cu 2p spectra, a larger energy separation between the satellite and main peaks (E{sub s}-E{sub m}) and a lower intensity ratio (I{sub s}/I{sub m}) are found to correlate with higher values of T{sub c}. Analysis of these spectra within a simple configuration interaction model suggests that higher values of T{sub c} are related to low values of the O 2p {r_arrow} Cu 3d charge transfer energy. In the O 1s region, a smaller bond length between Ba and Cu-O planar oxygen is found to correlate with a lower binding energy for the signal associated with Cu-O bonding, most likely resulting from the increased polarization screening by Ba{sup 2+} ions. For samples near optimum doping, maximum T{sub c} is observed to occur when the Tl 4f{sub 7/2} binding energy is near 117.9 eV, which is near the middle of the range of values observed for Tl cuprates. Higher Tl 4f{sub 7/2} binding energies, corresponding to formal oxidation states nearer Tl{sup 1+}, are also found to correlate with longer bond lengths between Ba and Tl-O planar oxygen, and with higher binding energies of the O 1s signal associated with Tl-O bonding.

  1. Chemical bonding in Tl cuprates studied by x-ray photoemission

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, R.P. [Center for Space Microelectronics Technology, Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California 91109-8099 (United States); Siegal, M.P.; Overmyer, D.L. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States); Ren, Z.F.; Lao, J.Y.; Wang, J.H. [Materials Synthesis Laboratory, Department of Chemistry, State University of New York, Buffalo, New York 14260-3000 (United States)

    1999-08-01

    Epitaxial thin films of the Tl cuprate superconductors Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8}, Tl{sub 2}Ba{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10}, and Tl{sub 0.78}Bi{sub 0.22}Ba{sub 0.4}Sr{sub 1.6}Ca{sub 2}Cu{sub 3}O{sub 9{minus}{delta}} are studied with x-ray photoemission spectroscopy. These data, together with previous measurements in this lab of Tl{sub 2}Ba{sub 2}CuO{sub 6+{delta}} and TlBa{sub 2}CaCu{sub 2}O{sub 7{minus}{delta}}, comprise a comprehensive data set for a comparative study of Tl cuprates with a range of chemical and electronic properties. In the Cu 2p spectra, a larger energy separation between the satellite and main peaks (E{sub s}{minus}E{sub m}) and a lower intensity ratio (I{sub s}/I{sub m}) are found to correlate with higher values of T{sub c}. Analysis of these spectra within a simple configuration interaction model suggests that higher values of T{sub c} are related to low values of the O&hthinsp;2p{r_arrow}Cu&hthinsp;3d charge transfer energy. In the O&hthinsp;1s region, a smaller bond length between Ba and Cu-O planar oxygen is found to correlate with a lower binding energy for the signal associated with Cu-O bonding, most likely resulting from the increased polarization screening by Ba{sup 2+} ions. For samples near optimum doping, maximum T{sub c} is observed to occur when the Tl 4f{sub 7/2} binding energy is near 117.9 eV, which is near the middle of the range of values observed for Tl cuprates. Higher Tl&hthinsp;4f{sub 7/2} binding energies, corresponding to formal oxidation states nearer Tl{sup 1+}, are also found to correlate with longer bond lengths between Ba and Tl-O planar oxygen, and with higher binding energies of the O&hthinsp;1s signal associated with Tl-O bonding. {copyright} {ital 1999} {ital The American Physical Society}

  2. Core-level photoabsorption study of defects and metastable bonding configurations in boron nitride

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez, I.; Jankowski, A.F.; Terminello, L.J. [Lawrence Berkeley National Lab., CA (United States)] [and others

    1997-04-01

    Boron nitride is an interesting material for technological applications and for fundamental solid state physics investigations. It is a compound isoelectronic with carbon and, like carbon can possess sp{sup 2} and sp{sup 3} bonded phases resembling graphite and diamond. BN crystallizes in the sp{sup 2}-bonded hexagonal (h-BN), rhombohedral (r-BN) and turbostratic phases, and in the sp{sup 3}-bonded cubic (c-BN) and wurtzite (w-BN) phases. A new family of materials is obtained when replacing C-C pairs in graphite with isoelectronic B-N pairs, resulting in C{sub 2}BN compounds. Regarding other boron compounds, BN is exceptional in the sense that it has standard two-center bonds with conventional coordination numbers, while other boron compounds (e.g. B{sub 4}C) are based on the boron icosahedron unit with three-center bonds and high coordination numbers. The existence of several allotropic forms and fullerene-like structures for BN suggests a rich variety of local bonding and poses the questions of how this affects the local electronic structure and how the material accommodates the stress induced in the transition regions between different phases. One would expect point defects to play a crucial role in stress accommodation, but these must also have a strong influence in the electronic structure, since the B-N bond is polar and a point defect will thus be a charged structure. The study of point defects in relationship to the electronic structure is of fundamental interest in these materials. Recently, the authors have shown that Near-Edge X-ray Absorption Fine Structure (NEXAFS) is sensitive to point defects in h-BN, and to the formation of metastable phases even in amorphous materials. This is significant since other phase identification techniques like vibrational spectroscopies or x-ray diffraction yield ambiguous results for nanocrystalline and amorphous samples. Serendipitously, NEXAFS also combines chemical selectivity with point defect sensitivity.

  3. The adsorption of acrolein on a Pt (1 1 1): A study of chemical bonding and electronic structure

    Science.gov (United States)

    Pirillo, S.; López-Corral, I.; Germán, E.; Juan, A.

    2012-12-01

    The adsorption of acrolein on a Pt (1 1 1) surface was studied using ab-initio and semiempirical calculations. Geometry optimization and densities of states (DOS) curves were carried out using the Vienna Ab-initio Simulation Package (VASP) code. We started our study with the preferential geometries corresponding to the different acrolein/Pt (1 1 1) adsorption modes previously reported. Then, we examined the evolution of the chemical bonding in these geometries, using the crystal orbital overlap population (COOP) and overlap population (OP) analysis of selected pairs of atoms. We analyzed the acrolein intramolecular bonds, Pt (1 1 1) superficial bonds and new moleculesbnd surface formed bonds after adsorption. We found that Ptsbnd Pt bonds interacting with the molecule and acrolein Cdbnd O and Cdbnd C bonds are weakened after adsorption; this last bond is significantly linked to the surface. The obtained Csbnd Pt and Osbnd Pt OP values suggest that the most stable adsorption modes are η3-cis and η4-trans, while the η1-trans is the less favored configuration. We also found that C pz orbital and Pt pz and d orbitals participate strongly in the adsorption process.

  4. Bond and Equity Home Bias and Foreign Bias: an International Study

    OpenAIRE

    VanPée, Rosanne; De Moor, Lieven

    2012-01-01

    In this paper we explore tentatively and formally the differences between bond and equity home bias and foreign bias based on one large scale dataset including developed and emerging markets for the period 2001 to 2010. We set the stage by tentatively and formally linking the diversion of bond and equity home bias in OECD countries to the increasing public debt issues under the form of government bonds i.e. the supply-driven argument. Unlike Fidora et al. (2007) we do not find that exchange r...

  5. Comparative evaluation of shear bond strength of zirconia restorations cleansed various cleansing protocols bonded with two different resin cements: An In vitro study

    Directory of Open Access Journals (Sweden)

    Sriram Sankar

    2017-01-01

    Full Text Available Context: Yttria partially stabilized tetragonal zirconia polycrystalline restorations have gained widespread use because of its enhanced strength and esthetics. During the try-in process, zirconia is likely to be contaminated with saliva. This contamination leads to a clear weakening of the bond between restorative material and cement. For this reason, zirconia surface should be cleaned before cementation. Hence, the purpose of this study is to compare the shear bond strength of zirconia restorations cleansed with various surface cleansing protocols bonded with two different resin cements. Materials and Methods: Eighty samples of zirconia discs were prepared in the dimensions 2.5 mm diameter and 4.5 mm thickness. They were divided into two groups of each forty samples based on luting cement used. Each group was further subdivided into four subgroups of each (n = 10: Group 1: uncontaminated zirconia blocks, Group 2: saliva-contaminated zirconia blocks and cleaned only with distilled water, Group 3: saliva-contaminated zirconia blocks treated with Ivoclean, and Group 4: saliva-contaminated zirconia blocks were air abraded. Eighty human maxillary premolars were then sectioned to expose dentin and were mounted on an acrylic block. A jig was fabricated to bond zirconia with the tooth using two self-adhesive resin cements. The samples were subjected to shear bond strength testing. The data were analyzed using one-way analysis of variance and Tukey's honest significance difference test with a level of significance set at p < 0.05. Results: The mean shear bond strength values of Group 1 and 2 - subgroup B are 10.3 ± 0.4 and 9.80 ± 0.7 (saliva-contaminated zirconia, cleansed with distilled water only, respectively, were lowest among all test subgroups and were significantly less than mean values of subgroup C, Group 1 - 20.45 ± 0.6 and Group 2 - 20.75 ± 0.4 (Ivoclean group and subgroup D, Group 1 - 20.90 ± 0.3 and Group 2 - 20.60 ± 0.5 (air

  6. A bonding study of c-C5H8 adsorption on Pt(111)

    International Nuclear Information System (INIS)

    Simonetti, S.; Jasen, P.; Gonzalez, E.; Juan, A.; Brizuela, G.

    2006-01-01

    The chemisorption of cyclopentane (c-C 5 H 8 ) on Pt(111) has been studied using a qualitative band-structure calculations in the framework of tight-binding implementation with the YAeHMOP package. We modeled the metal surface by a two-dimensional slab of finite thickness with an overlayer of c-C 5 H 8 , in a (3x3) di-σ geometry. The c-C 5 H 8 molecule is attached to the surface with its C?C atoms bonded mainly with two Pt atoms while the opposite CH 2 bends towards the surface. The Pt?Pt bonds in the underlying surface and the C?C bonds of c-C 5 H 8 are weakened upon the chemisorption. A noticeable Pt-H and Pt-C interactions has been observed. We found that of Pt 5d z 2 band plays an important role in the bonding between c-C 5 H 8 and the surface, as do the Pt 6s and 6p z bands. The HOMO-LUMO bands of c-C 5 H 8 are very dispersed, indicative of a strong interaction with the metal surface

  7. Pricing catastrophic bonds for earthquakes in Mexico

    OpenAIRE

    Cabrera, Brenda López

    2006-01-01

    After the occurrence of a natural disaster, the reconstruction can be financed with catastrophic bonds (CAT bonds) or reinsurance. For insurers, reinsurers and other corporations CAT bonds provide multi year protection without the credit risk present in reinsurance. For investors CAT bonds offer attractive returns and reduction of portfolio risk, since CAT bonds defaults are uncorrelated with defaults of other securities. As the study of natural catastrophe models plays an important role in t...

  8. Chemical bond fundamental aspects of chemical bonding

    CERN Document Server

    Frenking, Gernot

    2014-01-01

    This is the perfect complement to ""Chemical Bonding - Across the Periodic Table"" by the same editors, who are two of the top scientists working on this topic, each with extensive experience and important connections within the community. The resulting book is a unique overview of the different approaches used for describing a chemical bond, including molecular-orbital based, valence-bond based, ELF, AIM and density-functional based methods. It takes into account the many developments that have taken place in the field over the past few decades due to the rapid advances in quantum chemica

  9. Shear bond strength of orthodontic brackets bonded with different self-etching adhesives.

    Science.gov (United States)

    Scougall Vilchis, Rogelio José; Yamamoto, Seigo; Kitai, Noriyuki; Yamamoto, Kohji

    2009-09-01

    The purpose of this study was to compare the shear bond strength (SBS) of orthodontic brackets bonded with 4 self-etching adhesives. A total of 175 extracted premolars were randomly divided into 5 groups (n = 35). Group I was the control, in which the enamel was etched with 37% phosphoric acid, and stainless steel brackets were bonded with Transbond XT (3M Unitek, Monrovia, Calif). In the remaining 4 groups, the enamel was conditioned with the following self-etching primers and adhesives: group II, Transbond Plus and Transbond XT (3M Unitek); group III, Clearfil Mega Bond FA and Kurasper F (Kuraray Medical, Tokyo, Japan); group IV, Primers A and B, and BeautyOrtho Bond (Shofu, Kyoto, Japan); and group V, AdheSE and Heliosit Orthodontic (Ivoclar Vivadent AG, Liechtenstein). The teeth were stored in distilled water at 37 degrees C for 24 hours and debonded with a universal testing machine. The adhesive remnant index (ARI) including enamel fracture score was also evaluated. Additionally, the conditioned enamel surfaces were observed under a scanning electron microscope. The SBS values of groups I (19.0 +/- 6.7 MPa) and II (16.6 +/- 7.3 MPa) were significantly higher than those of groups III (11.0 +/- 3.9 MPa), IV (10.1 +/- 3.7 MPa), and V (11.8 +/- 3.5 MPa). Fluoride-releasing adhesives (Kurasper F and BeautyOrtho Bond) showed clinically acceptable SBS values. Significant differences were found in the ARI and enamel fracture scores between groups I and II. The 4 self-etching adhesives yielded SBS values higher than the bond strength (5.9 to 7.8 MPa) suggested for routine clinical treatment, indicating that orthodontic brackets can be successfully bonded with any of these self-etching adhesives.

  10. Adhesives for orthodontic bracket bonding

    Directory of Open Access Journals (Sweden)

    Déborah Daniella Diniz Fonseca

    2010-04-01

    Full Text Available The advent of acid etching, introduced by Buonocore in 1955, brought the possibility of bonding between the bracket base and enamel, contributing to more esthetic and conservative orthodontics. This direct bracket bonding technique has brought benefits such as reduced cost and time in performing the treatment, as well as making it easier to perform oral hygiene. The aim of this study was to conduct a survey of published studies on orthodontic bracket bonding to dental enamel. It was verified that resin composites and glass ionomer are the most studied and researched materials for this purpose. Resin-modified glass ionomer, with its biocompatibility, capacity of releasing fluoride and no need for acid etching on the tooth structure, has become increasingly popular among dentists. However, due to the esthetic and mechanical properties of light polymerizable resin composite, it continues to be one of the adhesives of choice in the bracket bonding technique and its use is widely disseminated.

  11. New generation of color bonding: A comparative in vitro study

    Directory of Open Access Journals (Sweden)

    Rajkumar Maurya

    2011-01-01

    Statistical Analysis: Comparison of the mean rank among the groups was done by Kruskal-Wallis one-way analysis of variance (ANOVA. To determine the mean difference among groups, the Mann-Whitney test with Bon Ferroni adjustment was applied. Observations: It was observed that light-cure conventional composite resin with the conventional etchant group had the highest and glass ionomer resin adhesive had the lowest shear bond strength. There was no statistically significant difference between conventional composite used with conventional etchant and color-changing composite resin used with conventional etchant or with self-etch primer. Conclusion: Considering the advantages of a color-changing composite and self-etch primer especially in patients having high DMFT scores or physically and mentally compromised patients unable to maintain their hygiene properly, it was concluded in the present study that it would be the most suitable material for direct bonding.

  12. Fracture surface analysis in composite and titanium bonding: Part 1: Titanium bonding

    Science.gov (United States)

    Sanderson, K. A.; Wightman, J. P.

    1985-01-01

    Fractured lap shear Ti 6-4 adherends bonded with polyphenyquinoxaline (PPQ) and polysulfone were analyzed. The effects of adherend pretreatment, stress level, thermal aging, anodizing voltage, and modified adhesive of Ti 6-4 adherend bonded with PPQ on lap shear strength were studied. The effect of adherend pretreatment on lap shear strength was investigated for PS samples. Results of scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) used to study the surface topography and surface composition are also discussed.

  13. Effect of various commercially available mouthrinses on shear bond strength of orthodontic metal brackets: An in vitro study

    Directory of Open Access Journals (Sweden)

    Nazeer Ahmed Meeran

    2013-01-01

    Conclusion: Alcohol containing mouthrinses affect the shear bond strength of the metal orthodontic brackets bonded with composite resin (Transbond XT in the present study, more when compared with alcohol-free mouthrinses. It is, therefore, highly advisable to avoid alcohol containing mouthrinses in patients undergoing orthodontic treatment and use alcohol-free mouthrinses as adjuncts to regular oral hygiene procedures for maintaining good enamel integrity and periodontal health, without compromising the shear bond strength of the bonded metal brackets.

  14. Ultrasonographic assessment of tendon thickness, Doppler activity and bony spurs of the elbow in patients with lateral epicondylitis and healthy subjects

    DEFF Research Database (Denmark)

    Krogh, T P; Fredberg, U; Christensen, Robin

    2013-01-01

    PURPOSE: Tennis elbow, also known as lateral epicondylitis (LE), is a common disorder often assessed by ultrasound. The aim of this study was to evaluate the ultrasonographic outcomes and methods used in LE research and clinical practice. MATERIALS AND METHODS: This study was designed as an intra......- and interobserver reliability and agreement study. Ultrasonographic examination of the common extensor tendon of the elbow was performed. The intraobserver study examined tendon thickness twice in 20 right elbows from 20 healthy individuals at an interval of 7 to 12 days. The interobserver study examined tendon...... thickness, color Doppler activity, and bony spurs in 18 right elbows in 9 healthy individuals and 9 patients with LE. Two trained rheumatologists performed the interobserver examinations with the same scanner on the same day. The main outcomes were intra- and interclass correlation (ICC) and agreement...

  15. A comparative computational study of Csbnd N and Csbnd C bonding visible to NIR absorbing croconines

    Science.gov (United States)

    Chetti, Prabhakar; Tripathi, Anuj

    2018-03-01

    The lowest electronic excitations and charge transfer properties in two series of croconine dyes; 1) molecules with Csbnd N bonding, having an absorption in the visible region (400-600 nm) and 2) molecules with Csbnd C bonding, showing absorption in visible to near infrared (NIR) region (600-1100 nm) are analyzed by quantum-chemical calculations. The absorption maxima in Csbnd C bonding croconines (CCR) are always having 200-300 nm red shifted than its corresponding Csbnd N bonding croconines (NCR). The reason for this drastic red shift in CCR series than its corresponding NCR has been systematically studied by DFT, TDDFT and SAC-CI methods. It is found that, CCR series are with less charge transfer in nature and are having larger diradical character, whereas NCR series molecules showing larger charge transfer with lower diradical character. The change in bonding mode of central five membered croconate ring, from Csbnd N to Csbnd C, destabilization and/stabilization of HOMO LUMO levels were observed. This study may helpful in the design and synthesis of new visible to NIR absorbing croconine dyes which are useful in materials applications.

  16. Automated bony region identification using artificial neural networks: reliability and validation measurements

    International Nuclear Information System (INIS)

    Gassman, Esther E.; Kallemeyn, Nicole A.; DeVries, Nicole A.; Shivanna, Kiran H.; Powell, Stephanie M.; Magnotta, Vincent A.; Ramme, Austin J.; Adams, Brian D.; Grosland, Nicole M.

    2008-01-01

    The objective was to develop tools for automating the identification of bony structures, to assess the reliability of this technique against manual raters, and to validate the resulting regions of interest against physical surface scans obtained from the same specimen. Artificial intelligence-based algorithms have been used for image segmentation, specifically artificial neural networks (ANNs). For this study, an ANN was created and trained to identify the phalanges of the human hand. The relative overlap between the ANN and a manual tracer was 0.87, 0.82, and 0.76, for the proximal, middle, and distal index phalanx bones respectively. Compared with the physical surface scans, the ANN-generated surface representations differed on average by 0.35 mm, 0.29 mm, and 0.40 mm for the proximal, middle, and distal phalanges respectively. Furthermore, the ANN proved to segment the structures in less than one-tenth of the time required by a manual rater. The ANN has proven to be a reliable and valid means of segmenting the phalanx bones from CT images. Employing automated methods such as the ANN for segmentation, eliminates the likelihood of rater drift and inter-rater variability. Automated methods also decrease the amount of time and manual effort required to extract the data of interest, thereby making the feasibility of patient-specific modeling a reality. (orig.)

  17. Automated bony region identification using artificial neural networks: reliability and validation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Gassman, Esther E.; Kallemeyn, Nicole A.; DeVries, Nicole A.; Shivanna, Kiran H. [The University of Iowa, Department of Biomedical Engineering, Seamans Center for the Engineering Arts and Sciences, Iowa City, IA (United States); The University of Iowa, Center for Computer-Aided Design, Iowa City, IA (United States); Powell, Stephanie M. [The University of Iowa, Department of Biomedical Engineering, Seamans Center for the Engineering Arts and Sciences, Iowa City, IA (United States); University of Iowa Hospitals and Clinics, The University of Iowa, Department of Radiology, Iowa City, IA (United States); Magnotta, Vincent A. [The University of Iowa, Department of Biomedical Engineering, Seamans Center for the Engineering Arts and Sciences, Iowa City, IA (United States); The University of Iowa, Center for Computer-Aided Design, Iowa City, IA (United States); University of Iowa Hospitals and Clinics, The University of Iowa, Department of Radiology, Iowa City, IA (United States); Ramme, Austin J. [University of Iowa Hospitals and Clinics, The University of Iowa, Department of Radiology, Iowa City, IA (United States); Adams, Brian D. [The University of Iowa, Department of Biomedical Engineering, Seamans Center for the Engineering Arts and Sciences, Iowa City, IA (United States); University of Iowa Hospitals and Clinics, The University of Iowa, Department of Orthopaedics and Rehabilitation, Iowa City, IA (United States); Grosland, Nicole M. [The University of Iowa, Department of Biomedical Engineering, Seamans Center for the Engineering Arts and Sciences, Iowa City, IA (United States); University of Iowa Hospitals and Clinics, The University of Iowa, Department of Orthopaedics and Rehabilitation, Iowa City, IA (United States); The University of Iowa, Center for Computer-Aided Design, Iowa City, IA (United States)

    2008-04-15

    The objective was to develop tools for automating the identification of bony structures, to assess the reliability of this technique against manual raters, and to validate the resulting regions of interest against physical surface scans obtained from the same specimen. Artificial intelligence-based algorithms have been used for image segmentation, specifically artificial neural networks (ANNs). For this study, an ANN was created and trained to identify the phalanges of the human hand. The relative overlap between the ANN and a manual tracer was 0.87, 0.82, and 0.76, for the proximal, middle, and distal index phalanx bones respectively. Compared with the physical surface scans, the ANN-generated surface representations differed on average by 0.35 mm, 0.29 mm, and 0.40 mm for the proximal, middle, and distal phalanges respectively. Furthermore, the ANN proved to segment the structures in less than one-tenth of the time required by a manual rater. The ANN has proven to be a reliable and valid means of segmenting the phalanx bones from CT images. Employing automated methods such as the ANN for segmentation, eliminates the likelihood of rater drift and inter-rater variability. Automated methods also decrease the amount of time and manual effort required to extract the data of interest, thereby making the feasibility of patient-specific modeling a reality. (orig.)

  18. Wire bonding in microelectronics

    CERN Document Server

    Harman, George G

    2010-01-01

    Wire Bonding in Microelectronics, Third Edition, has been thoroughly revised to help you meet the challenges of today's small-scale and fine-pitch microelectronics. This authoritative guide covers every aspect of designing, manufacturing, and evaluating wire bonds engineered with cutting-edge techniques. In addition to gaining a full grasp of bonding technology, you'll learn how to create reliable bonds at exceedingly high yields, test wire bonds, solve common bonding problems, implement molecular cleaning methods, and much more. Coverage includes: Ultrasonic bonding systems and technologies, including high-frequency systems Bonding wire metallurgy and characteristics, including copper wire Wire bond testing Gold-aluminum intermetallic compounds and other interface reactions Gold and nickel-based bond pad plating materials and problems Cleaning to improve bondability and reliability Mechanical problems in wire bonding High-yield, fine-pitch, specialized-looping, soft-substrate, and extreme-temperature wire bo...

  19. Short strong hydrogen bonds in proteins: a case study of rhamnogalacturonan acetylesterase

    International Nuclear Information System (INIS)

    Langkilde, Annette; Kristensen, Søren M.; Lo Leggio, Leila; Mølgaard, Anne; Jensen, Jan H.; Houk, Andrew R.; Navarro Poulsen, Jens-Christian; Kauppinen, Sakari; Larsen, Sine

    2008-01-01

    The short hydrogen bonds in rhamnogalacturonan acetylesterase have been investigated by structure determination of an active-site mutant, 1 H NMR spectra and computational methods. Comparisons are made to database statistics. A very short carboxylic acid carboxylate hydrogen bond, buried in the protein, could explain the low-field (18 p.p.m.) 1 H NMR signal. An extremely low-field signal (at approximately 18 p.p.m.) in the 1 H NMR spectrum of rhamnogalacturonan acetylesterase (RGAE) shows the presence of a short strong hydrogen bond in the structure. This signal was also present in the mutant RGAE D192N, in which Asp192, which is part of the catalytic triad, has been replaced with Asn. A careful analysis of wild-type RGAE and RGAE D192N was conducted with the purpose of identifying possible candidates for the short hydrogen bond with the 18 p.p.m. deshielded proton. Theoretical calculations of chemical shift values were used in the interpretation of the experimental 1 H NMR spectra. The crystal structure of RGAE D192N was determined to 1.33 Å resolution and refined to an R value of 11.6% for all data. The structure is virtually identical to the high-resolution (1.12 Å) structure of the wild-type enzyme except for the interactions involving the mutation and a disordered loop. Searches of the Cambridge Structural Database were conducted to obtain information on the donor–acceptor distances of different types of hydrogen bonds. The short hydrogen-bond interactions found in RGAE have equivalents in small-molecule structures. An examination of the short hydrogen bonds in RGAE, the calculated pK a values and solvent-accessibilities identified a buried carboxylic acid carboxylate hydrogen bond between Asp75 and Asp87 as the likely origin of the 18 p.p.m. signal. Similar hydrogen-bond interactions between two Asp or Glu carboxy groups were found in 16% of a homology-reduced set of high-quality structures extracted from the PDB. The shortest hydrogen bonds in RGAE are

  20. Solid-liquid interdiffusion (SLID) bonding in the Au-In system: experimental study and 1D modelling

    Science.gov (United States)

    Deillon, Léa; Hessler-Wyser, Aïcha; Hessler, Thierry; Rappaz, Michel

    2015-12-01

    Au-In bonds with a nominal composition of about 60 at.% In were fabricated for use in wafer-level packaging of MEMS. The microstructure of the bonds was studied by scanning electron microscopy. The bond hermeticity was then assessed using oxidation of Cu thin discs predeposited within the sealed packages. The three intermetallic compounds AuIn2, AuIn and Au7In3 were observed. Their thickness evolution during bonding and after subsequent heat treatment was successfully modelled using a finite difference model of diffusion, thermodynamic data and diffusion coefficients calibrated from isothermal diffusion couples. 17% of the packages were hermetic and, although the origin of the leaks could not be clearly identified, it appeared that hermeticity was correlated with the unevenness of the metallisation and/or wafer and the fact that the bonds shrink due to density differences as the relative fractions of the various phases gradually evolve.

  1. Solid-liquid interdiffusion (SLID) bonding in the Au–In system: experimental study and 1D modelling

    International Nuclear Information System (INIS)

    Deillon, Léa; Hessler-Wyser, Aïcha; Hessler, Thierry; Rappaz, Michel

    2015-01-01

    Au–In bonds with a nominal composition of about 60 at.% In were fabricated for use in wafer-level packaging of MEMS. The microstructure of the bonds was studied by scanning electron microscopy. The bond hermeticity was then assessed using oxidation of Cu thin discs predeposited within the sealed packages. The three intermetallic compounds AuIn 2 , AuIn and Au 7 In 3 were observed. Their thickness evolution during bonding and after subsequent heat treatment was successfully modelled using a finite difference model of diffusion, thermodynamic data and diffusion coefficients calibrated from isothermal diffusion couples. 17% of the packages were hermetic and, although the origin of the leaks could not be clearly identified, it appeared that hermeticity was correlated with the unevenness of the metallisation and/or wafer and the fact that the bonds shrink due to density differences as the relative fractions of the various phases gradually evolve. (paper)

  2. Physical mechanisms of Cu-Cu wafer bonding

    International Nuclear Information System (INIS)

    Rebhan, B.

    2014-01-01

    Modern manufacturing processes of complex integrated semiconductor devices are based on wafer-level manufacturing of components which are subsequently interconnected. When compared with classical monolithic bi-dimensional integrated circuits (2D ICs), the new approach of three-dimensional integrated circuits (3D ICs) exhibits significant benefits in terms of signal propagation delay and power consumption due to the reduced metal interconnection length and allows high integration levels with reduced form factor. Metal thermo-compression bonding is a process suitable for 3D interconnects applications at wafer level, which facilitates the electrical and mechanical connection of two wafers even processed in different technologies, such as complementary metal oxide semiconductor (CMOS) and microelectromechanical systems (MEMS). Due to its high electrical conductivity, copper is a very attractive material for electrical interconnects. For Cu-Cu wafer bonding the process requires typically bonding for around 1 h at 400°C and high contact pressure applied during bonding. Temperature reduction below such values is required in order to solve issues regarding (i) throughput in the wafer bonder, (ii) wafer-to-wafer misalignment after bonding and (iii) to minimise thermo-mechanical stresses or device degradation. The aim of this work was to study the physical mechanisms of Cu-Cu bonding and based on this study to further optimise the bonding process for low temperatures. The critical sample parameters (roughness, oxide, crystallinity) were identified using selected analytical techniques and correlated with the characteristics of the bonded Cu-Cu interfaces. Based on the results of this study the impact of several materials and process specifications on the bonding result were theoretically defined and experimentally proven. These fundamental findings subsequently facilitated low temperature (LT) metal thermo-compression Cu-Cu wafer bonding and even room temperature direct

  3. SOCIAL BONDING: REGULATION BY NEUROPEPTIDES

    Directory of Open Access Journals (Sweden)

    Claudia eLieberwirth

    2014-06-01

    Full Text Available Affiliative social relationships (e.g., among spouses, family members, and friends play an essential role in human society. These relationships affect psychological, physiological, and behavioral functions. As positive and enduring bonds are critical for the overall well-being of humans, it is not surprising that considerable effort has been made to study the neurobiological mechanisms that underlie social bonding behaviors. The present review details the involvement of the nonapeptides, oxytocin (OT and arginine vasopressin (AVP, in the regulation of social bonding in mammals including humans. In particular, we will discuss the role of OT and AVP in the formation of social bonds between partners of a mating pair as well as between parents and their offspring. Furthermore, the role of OT and AVP in the formation of interpersonal bonding involving trust is also discussed.

  4. Analysis of factors influencing the bond strength in roll bonding processes

    Science.gov (United States)

    Khaledi, Kavan; Wulfinghoff, Stephan; Reese, Stefanie

    2018-05-01

    Cold Roll Bonding (CRB) is recognized as an industrial technique in which the metal sheets are joined together in order to produce laminate metal composites. In this technique, a metallurgical bond resulting from severe plastic deformation is formed between the rolled metallic layers. The main objective of this paper is to analyse different factors which may affect the bond formation in rolling processes. To achieve this goal, first, an interface model is employed which describes both the bonding and debonding. In this model, the bond strength evolution between the metallic layers is calculated based on the film theory of bonding. On the other hand, the debonding process is modelled by means of a bilinear cohesive zone model. In the numerical section, different scenarios are taken into account to model the roll bonding process of metal sheets. The numerical simulation includes the modelling of joining during the roll bonding process followed by debonding in a Double Cantilever Beam (DCB) peeling test. In all simulations, the metallic layers are regarded as elastoplastic materials subjected to large plastic deformations. Finally, the effects of some important factors on the bond formation are numerically investigated.

  5. Effect of salivary contamination on shear bond strength of two adhesives: An in vitro study

    Directory of Open Access Journals (Sweden)

    Shruti B Patil

    2014-01-01

    Full Text Available Introduction: Composite material used with bonding system are technique sensitive and contamination of an etched surface by saliva or blood plays a key role in bonding efficacy. Achieving good moisture control is a common problem encountered and is of importance while treating a pediatric age group since rubber dam in dental office is commonly applied in fewer than 10% of restorative treatment. Despite the advantage of rubber dam application, usage of rubber dam depends on child′s behavior and its level of co-operation for which pediatric dentists compromise with its usage. This study was conducted to evaluate the effect of salivary contamination of enamel and dentin on bond strength of two adhesives. Materials and Methods: An in vitro study comprised of test group of 112 central incisors divided into 4 groups for testing on enamel and dentin separately. These are Group I: Control group without salivary contamination; Group II: Contaminated with saliva and air-dried; Group III: Contaminated with saliva, rinsed and air-dried; Group IV: Coated with adhesive, light cured and then contaminated. Shear bond strength was calculated using universal testing machine. Results: For testing on enamel and dentin, significantly decreased bond strength was seen with Group II (P 0.05, when compared with control Group I. Conclusion: The decontamination method used in this study by rinsing the contaminated cured adhesive layer that did not reverse the harmful effect of salivary contamination. As most of the children are active and restless with swinging mood, it is important not to negotiate with the procedural steps during treatment.

  6. Thoracic hyperextension injury with complete “bony disruption” of the thoracic cage: Case report of a potentially life-threatening injury

    Directory of Open Access Journals (Sweden)

    Bailey James

    2012-05-01

    Full Text Available Abstract Background Severe chest wall injuries are potentially life-threatening injuries which require a standardized multidisciplinary management strategy for prevention of posttraumatic complications and adverse outcome. Case presentation We report the successful management of a 55-year old man who sustained a complete “bony disruption” of the thoracic cage secondary to an “all-terrain vehicle” roll-over accident. The injury pattern consisted of a bilateral “flail chest” with serial segmental rib fractures, bilateral hemo-pneumothoraces and pulmonary contusions, bilateral midshaft clavicle fractures, a displaced transverse sternum fracture with significant diastasis, and an unstable T9 hyperextension injury. After initial life-saving procedures, the chest wall injuries were sequentially stabilized by surgical fixation of bilateral clavicle fractures, locked plating of the displaced sternal fracture, and a two-level anterior spine fixation of the T9 hyperextension injury. The patient had an excellent radiological and physiological outcome at 6 months post injury. Conclusion Severe chest wall trauma with a complete “bony disruption” of the thoracic cage represents a rare, but detrimental injury pattern. Multidisciplinary management with a staged timing for addressing each of the critical injuries, represents the ideal approach for an excellent long-term outcome.

  7. Taxonomic composition and trophic structure of the continental bony fish assemblage from the early late cretaceous of Southeastern Morocco.

    Science.gov (United States)

    Cavin, Lionel; Boudad, Larbi; Tong, Haiyan; Läng, Emilie; Tabouelle, Jérôme; Vullo, Romain

    2015-01-01

    The mid-Cretaceous vertebrate assemblage from south-eastern Morocco is one of the most diversified continental vertebrate assemblages of this time worldwide. The bony fish component (coelacanths, lungfishes and ray-finned fishes) is represented by relatively complete specimens and, mostly, by fragmentary elements scattered along 250 kilometres of outcrops. Here we revisit the bony fish assemblage by studying both isolated remains collected during several fieldtrips and more complete material kept in public collections. The assemblage comprises several lungfish taxa, with the first mention of the occurrence of Arganodus tiguidiensis, and possibly two mawsoniid coelacanths. A large bichir cf. Bawitius, is recorded and corresponds to cranial elements initially referred to 'Stromerichthys' from coeval deposits in Egypt. The ginglymodians were diversified with a large 'Lepidotes' plus two obaichthyids and a gar. We confirm here that this gar belongs to a genus distinctive from Recent gars, contrary to what was suggested recently. Teleosteans comprise a poorly known ichthyodectiform, a notopterid, a probable osteoglossomorph and a large tselfatiiform, whose cranial anatomy is detailed. The body size and trophic level for each taxon are estimated on the basis of comparison with extant closely related taxa. We plotted the average body size versus average trophic level for the Kem Kem assemblage, together with extant marine and freshwater assemblages. The Kem Kem assemblage is characterized by taxa of proportionally large body size, and by a higher average trophic level than the trophic level of the extant compared freshwater ecosystems, but lower than for the extant marine ecosystems. These results should be regarded with caution because they rest on a reconstructed assemblage known mostly by fragmentary remains. They reinforce, however, the ecological oddities already noticed for this mid-Cretaceous vertebrate ecosystem in North Africa.

  8. Exploring Determinant Factors of Bond Trading with Inventory Management Theory (Case Study of Indonesian Capital Market, January – March 2009

    Directory of Open Access Journals (Sweden)

    Imam Wahyudi

    2014-08-01

    Full Text Available This  paper  studies  trading  volume  of  206  recorded  and  publicly  traded  bonds  in  Indonesian Capital Market on January 4th - March 9th 2009 observed period. The data covers almost all trading data in the market and all brokers that exist. The microstructure data used in this study is a complete understanding for almost every phenomenons in the market, and thus could explain more about bond liquidity. We ind that some bonds are actively traded and most are rare. We also construct some determinant facto tests of bond trading volume, included  descriptive  statistic,  GLS,  and  other  formal  test.  We  ind  that  bonds  with  larger par value and more seasoned tend to have smaller trading volume. We also ind that private bonds are actively traded more than public bonds (both government institution and private institution  bond.  Interest  rate  risk  and  bond  price  volatility  are  positively  inluence  bond trading volume, but opposite for bond rating. We ind that bond with higher probability to default  have  smaller  trading  volume.  While  comparing  the  bond  volume  data  with  stock price data, we ind that the relationship in two markets is not linier as the convenient theory in inance said. ";} // -->activate javascript

  9. Intra- und intermolecular hydrogen bonds. Spectroscopic, quantum chemical and molecular dynamics studies

    International Nuclear Information System (INIS)

    Simperler, A.

    1999-03-01

    Intra- and intermolecular H-bonds have been investigated with spectroscopic, quantum chemical, and molecular dynamics methods. The work is divided into the following three parts: 1. Intramolecular interactions in ortho-substituted phenols. Theoretical and experimental data that characterizes the intramolecular hydrogen bonds in 48 different o-substituted phenols are discussed. The study covers various kinds of O-H ... Y -type interactions (Y= N, O, S, F, Cl, Br, I, C=C, C=-C, and C-=N). The bond strength sequences for several series of systematically related compounds as obtained from IR spectroscopy data (i.e., v(OH) stretching frequencies) are discussed and reproduced with several theoretical methods (B3LYP/6-31G(d,p), B3LYP/6-311G(d,p), B3LYP/6-31++G(d,p), B3LYP/DZVP, MP2/6-31G(d,p), and MP2/6-31++G(d,p) levels of theory). The experimentally determined sequences are interpreted in terms of the intrinsic properties of the molecules: hydrogen bond distances, Mulliken partial charges, van der Waals radii, and electron densities of the Y-proton acceptors. 2. Competitive hydrogen bonds and conformational equilibria in 2,6-disubstituted phenols containing two different carbonyl substituents. The rotational isomers of ten unsymmetrical 2,6-disubstituted phenols as obtained by combinations of five different carbonyl substituents (COOH, COOCH 3 , CHO, COCH 3 , and CONH 2 ) have been theoretically investigated at the B3LYP/6-31G(d,p) level of theory. The relative stability of four to five conformers of each compound were determined by full geometry optimization for free molecules as well as for molecules in reaction fields with dielectric constants up to ε=37.5. A comparison with IR spectroscopic data of available compounds revealed excellent agreement with the theoretically predicted stability sequences and conformational equilibria. The stability of a conformer could be interpreted to be governed by the following two contributions: (i) an attractive hydrogen bond

  10. Simultaneous bond degradation and bond formation during phenol-formaldehyde curing with wood

    Science.gov (United States)

    Daniel J. Yelle; John Ralph

    2016-01-01

    Bonding of wood using phenol–formaldehyde adhesive develops highly durable bonds. Phenol– formaldehyde is believed to form primary bonds with wood cell wall polymers (e.g., lignin). However, it is unclear how this adhesive interacts and bonds to lignin. Through wood solubilisation methodologies, earlywood and latewood bonded assemblies were characterized using two-...

  11. Destination bonding: Hybrid cognition using Instagram

    Directory of Open Access Journals (Sweden)

    Arup Kumar Baksi

    2015-01-01

    Full Text Available Empirical research has identified the phenomenon of destination bonding as a result of summated physical and emotional values associated with the destination. Physical values, namely natural landscape & other physical settings and emotional values, namely the enculturation processes, have a significant role to play in portraying visitors’ cognitive framework for destination preference. The physical values seemed to be the stimulator for bonding that embodies action or behavior tendencies in imagery. The emotional values were the conditions that lead to affective bonding and are reflected in attitudes for a place which were evident in text narratives. Social networking on virtual platforms offers the scope for hybrid cognitive expression using imagery and text to the visitors. Instagram has emerged as an application-window to capture these hybrid cognitions of visitors. This study focuses on assessing the relationship between hybrid cognition of visitors expressed via Instagram and their bond with the destination. Further to this, the study attempts to examine the impact of hybrid cognition of visitors on the behavioral pattern of prospective visitors to the destination. The study revealed that sharing of visual imageries and related text by the visitors is an expression of the physico-emotional bonding with the destination. It was further established that hybrid cognition strongly asserts destination bonding and has been also found to have moderating impact on the link between destination bonding and electronic-word-of-mouth.

  12. Composite Bonding to Stainless Steel Crowns Using a New Universal Bonding and Single-Bottle Systems

    OpenAIRE

    Mohammad Ali Hattan; Sharat Chandra Pani; Mohammad AlOmari

    2013-01-01

    Aim. The aim of this study is to evaluate the shear bond strength of nanocomposite to stainless steel crowns using a new universal bonding system. Material and Methods. Eighty (80) stainless steel crowns (SSCs) were divided into four groups (20 each). Packable nanocomposite was bonded to the lingual surface of the crowns in the following methods: Group A without adhesive (control group), Group B using a new universal adhesive system (Scotchbond Universal Adhesive, 3M ESPE, Seefeld, Germany), ...

  13. Bond strength of masonry

    NARCIS (Netherlands)

    Pluijm, van der R.; Vermeltfoort, A.Th.

    1992-01-01

    Bond strength is not a well defined property of masonry. Normally three types of bond strength can be distinguished: - tensile bond strength, - shear (and torsional) bond strength, - flexural bond strength. In this contribution the behaviour and strength of masonry in deformation controlled uniaxial

  14. Local electronic and geometrical structures of hydrogen-bonded complexes studied by soft X-ray spectroscopy

    International Nuclear Information System (INIS)

    Luo, Y.

    2004-01-01

    Full text: The hydrogen bond is one of the most important forms of intermolecular interactions. It occurs in all-important components of life. However, the electronic structures of hydrogen-bonded complexes in liquid phases have long been difficult to determine due to the lack of proper experimental techniques. In this talk, a recent joint theoretical and experimental effort to understand hydrogen bonding in liquid water and alcohol/water mixtures using synchrotron radiation based soft-X-ray spectroscopy will be presented. The complexity of the liquid systems has made it impossible to interpret the spectra with physical intuition alone. Theoretical simulations have thus played an essential role in understanding the spectra and providing valuable insights on the local geometrical and electronic structures of these liquids. Our study sheds light on a 40-year controversy over what kinds of molecular structures are formed in pure liquid methanol. It also suggests an explanation for the well-known puzzle of why alcohol and water do not mix completely: the system must balance nature's tendency toward greater disorder (entropy) with the molecules' tendency to form hydrogen bonds. The observation of electron sharing and broken hydrogen bonding local structures in liquid water will be presented. The possible use of X-ray spectroscopy to determinate the local arrangements of hydrogen-bonded nanostructures will also been discussed

  15. Comparative evaluation of shear bond strength of metallic brackets bonded with two different bonding agents under dry conditions and with saliva contamination

    Directory of Open Access Journals (Sweden)

    Mashallah Khanehmasjedi

    2017-02-01

    Conclusion: Application of Single Bond and Assure bonding agents resulted in adequate bond strength of brackets to tooth structures. Contamination with saliva significantly decreased the bond strength of Assure bonding agent compared with dry conditions.

  16. Bond strength and microleakage of current dentin adhesives.

    Science.gov (United States)

    Fortin, D; Swift, E J; Denehy, G E; Reinhardt, J W

    1994-07-01

    The purpose of this in vitro study was to evaluate shear bond strengths and microleakage of seven current-generation dentin adhesive systems. Standard box-type Class V cavity preparations were made at the cemento-enamel junction on the buccal surfaces of eighty extracted human molars. These preparations were restored using a microfill composite following application of either All-Bond 2 (Bisco), Clearfil Liner Bond (Kuraray), Gluma 2000 (Miles), Imperva Bond (Shofu), OptiBond (Kerr), Prisma Universal Bond 3 (Caulk), Scotchbond Multi-Purpose (3M), or Scotchbond Dual-Cure (3M) (control). Lingual dentin of these same teeth was exposed and polished to 600-grit. Adhesives were applied and composite was bonded to the dentin using a gelatin capsule technique. Specimens were thermocycled 500 times. Shear bond strengths were determined using a universal testing machine, and microleakage was evaluated using a standard silver nitrate staining technique. Clearfill Liner Bond and OptiBond, adhesive systems that include low-viscosity, low-modulus intermediate resins, had the highest shear bond strengths (13.3 +/- 2.3 MPa and 12.9 +/- 1.5 MPa, respectively). Along with Prisma Universal Bond 3, they also had the least microleakage at dentin margins of Class V restorations. No statistically significant correlation between shear bond strength and microleakage was observed in this study. Adhesive systems that include a low-viscosity intermediate resin produced the high bond strengths and low microleakage. Similarly, two materials with bond strengths in the intermediate range had significantly increased microleakage, and one material with a bond strength in the low end of the spectrum exhibited microleakage that was statistically greater. Thus, despite the lack of statistical correlation, there were observable trends.

  17. Evaluation of the anti-cariogenic potential and bond strength to enamel of different fluoridated materials used for bracket bonding

    Directory of Open Access Journals (Sweden)

    Sérgio Ricardo da SILVA

    2017-05-01

    Full Text Available Abstract Objective To evaluate the in vitro and in situ anti-cariogenic potential and bond strength to enamel of materials containing fluoride (F, used for bracket bonding: Transbond XT (GT, negative control, Transbond Plus Color Change (GTF, Transbond-Self-Etching Primer (GSAF and Vitremer (GV, positive control. Material and method In the in vitro study, the specimens were premolars with bonded brackets (n=12/group. After pH cycling, the F release, bond strength, fracture mode and presence of white spot lesions were assessed. In the in situ study, the specimens were enamel fragments with bonded brackets (n=12/group. Twelve volunteers wore palatal appliances in 4 phases, with cariogenic challenge. Bond strength, fracture mode and change in surface hardness (%SH were determined. Result Relative to the in vitro study, F release (ppm was: GT=0.257±0.068c; GTF=0.634±0.100b; GSAF=0.630±0.067b; GV=2.796±1.414a. Only GV showed no white spot lesions. Bond strength values (MPa were GT=7.62±7.18a; GTF=5.15±6.91ab; GSAF=3.42±2.97bc; GV=2.87±2.09c. Adhesive fracture was the most frequent type, except for GTF. In the in situ study, %SH was: GT=-56.0±18.3a; GTF=-57.6±11.9a; GSAF=-57.1±11.3a; GV=-52.4±25.8a. Bond strength values were GT=9.5±4.4a; GTF=11.1±5.9a; GSAF=13.2± 6.6a; GV=6.6±4.0a. Cohesive fracture in material was the most frequent type, except for GTF. Conclusion Vitremer (GV showed the highest anti-cariogenic potential in the in vitro study. However, it was not confirmed by the in situ study. Regarding bond strength values from the in situ study, all materials were shown to be adequate for clinical practice.

  18. GROUT-CONCRETE INTERFACE BOND PERFORMANCE: EFFECT OF INTERFACE MOISTURE ON THE TENSILE BOND STRENGTH AND GROUT MICROSTRUCTURE.

    Science.gov (United States)

    De la Varga, I; Muñoz, J F; Bentz, D P; Spragg, R P; Stutzman, P E; Graybeal, B A

    2018-05-01

    Bond between two cementitious materials is crucial in applications such as repairs, overlays, and connections of prefabricated bridge elements (PBEs), to name just a few. It is the latter that has special interest to the authors of this paper. After performing a dimensional stability study on grout-like materials commonly used as connections between PBEs, it was observed that the so-called 'non-shrink' cementitious grouts showed a considerable amount of early-age shrinkage. This might have negative effects on the integrity of the structure, due not only to the grout material's early degradation, but also to a possible loss of bond between the grout and the prefabricated concrete element. Many factors affect the bond strength between two cementitious materials (e.g., grout-concrete), the presence of moisture at the existing concrete substrate surface being one of them. In this regard, pre-moistening the concrete substrate surface prior to the application of the grout material is sometimes recommended for bond enhancement. This topic has been the focus of numerous research studies in the past; however, there is still controversy among practitioners on the real benefits that this practice might provide. This paper evaluates the tensile bond performance of two non-shrink cementitious grouts applied to the exposed aggregate surface of a concrete substrate, and how the supply of moisture at the grout-concrete interface affects the bond strength. "Pull-off" bond results show increased tensile bond strength when the concrete surface is pre-moistened. Reasons to explain the observed increased bond strength are given after a careful microstructural analysis of the grout-concrete interface. Interfaces where sufficient moisture is provided to the concrete substrate such that moisture movement from the grout is prevented show reduced porosity and increased hydration on the grout side of the interface, which is thought to directly contribute to the increased tensile bond

  19. Deproteinization of fluorosed enamel with sodium hypochlorite enhances the shear bond strength of orthodontic brackets: An In vitro study

    Directory of Open Access Journals (Sweden)

    Rekha Sharma

    2017-01-01

    Full Text Available Context: Improving bonding strength to fluorosed teeh. Aims: To determine the effect of deproteinization using 5.25% sodium hypochlorite (NaOCl prior to acid etching on shear bond strength of orthodontic brackets bonded to fluorosed teeth. Settings and Design: In vitro experimental study. Methods and Material: Forty freshly extracted human mandibular first premolars with TFI 4 were selected and divided into two groups of 20 each. In Group I the teeth were acid etched with 37% phosphoric acid and bonded with composite. In Group II the teeth were deproteinized with 5.25% NaOCl prior to acid etching with 37% phosphoric acid and were bonded with composite. Samples were then subjected to shear bond test by Instron Universal Testing machine. The sample from each group were selected for the SEM study (prior to bonding to analyze the etching patterns achieved. Statistical Analysis Used: Data was checked for normality by Shapiro Wilk Test, to compare the two groups unpaired t test was used. P value was predetermined at ≤ 0.05. Results: The S BS of Group II (11.75 ± 2.83 MPa was higher than Group I (7.44 ± 2.43 MPa and the difference was statistically significant (P = 0.000. On SEM the etching pattern was more of type 1 and 2 in Group II. Conclusions: Deproteinization using 5.25% NaOCl prior to acid etching significantly increases the shear bond strength of brackets bonded to fluorosed teeth and can be used as a convenient and effective option in orthodontic bonding to fluorosed teeth.

  20. Efficacy of microtensile versus microshear bond testing for evaluation of bond strength of dental adhesive systems to enamel

    NARCIS (Netherlands)

    El Zohairy, A.A.; Saber, M.H.; Abdalla, A.I.; Feilzer, A.J.

    2010-01-01

    Objective The aim of the study was to evaluate the efficacy of the microtensile bond test (μTBS) and the microshear bond test (μSBS) in ranking four dental adhesives according to bond strength to enamel and identify the modes of failure involved. Materials and methods Forty-four caries-free human

  1. Hexacoordinate bonding and aromaticity in silicon phthalocyanine.

    Science.gov (United States)

    Yang, Yang

    2010-12-23

    Si-E bondings in hexacoordinate silicon phthalocyanine were analyzed using bond order (BO), energy partition, atoms in molecules (AIM), electron localization function (ELF), and localized orbital locator (LOL). Bond models were proposed to explain differences between hexacoordinate and tetracoordinate Si-E bondings. Aromaticity of silicon phthalocyanine was investigated using nucleus-independent chemical shift (NICS), harmonic oscillator model of aromaticity (HOMA), conceptual density functional theory (DFT), ring critical point (RCP) descriptors, and delocalization index (DI). Structure, energy, bonding, and aromaticity of tetracoordinate silicon phthalocyanine were studied and compared with hexacoordinate one.

  2. Shear bond strength of self-etch and total-etch bonding systems at different dentin depths

    Directory of Open Access Journals (Sweden)

    Ana Carolina Maito Villela-Rosa

    2011-04-01

    Full Text Available The purpose of this study was to evaluate the dentin shear bond strength of four adhesive systems (Adper Single Bond 2, Adper Prompt L-Pop, Magic Bond DE and Self Etch Bond in regards to buccal and lingual surfaces and dentin depth. Forty extracted third molars had roots removed and crowns bisected in the mesiodistal direction. The buccal and lingual surfaces were fixed in a PVC/acrylic resin ring and were divided into buccal and lingual groups assigned to each selected adhesive. The same specimens prepared for the evaluation of superficial dentin shear resistance were used to evaluate the different depths of dentin. The specimens were identified and abraded at depths of 0.5, 1.0, 1.5 and 2.0 mm. Each depth was evaluated by ISO TR 11405 using an EMIC-2000 machine regulated at 0.5 mm/min with a 200 Kgf load cell. We performed statistical analyses on the results (ANOVA, Tukey and Scheffé tests. Data revealed statistical differences (p < 0.01 in the adhesive and depth variation as well as adhesive/depth interactions. The Adper Single Bond 2 demonstrated the highest mean values of shear bond strength. The Prompt L-Pop product, a self-etching adhesive, revealed higher mean values compared with Magic Bond DE and Self Etch Bond adhesives, a total and self-etching adhesive respectively. It may be concluded that the shear bond strength of dentin is dependent on material (adhesive system, substrate depth and adhesive/depth interaction.

  3. Pricing Chinese Convertible Bonds with Dynamic Credit Risk

    Directory of Open Access Journals (Sweden)

    Ping Li

    2014-01-01

    Full Text Available To price convertible bonds more precisely, least squares Monte Carlo (LSM method is used in this paper for its advantage in handling the dependence of derivatives on the path, and dynamic credit risk is used to replace the fixed one to make the value of convertible bonds reflect the real credit risk. In the empirical study, we price convertible bonds based on static credit risk and dynamic credit risk, respectively. Empirical results indicate that the ICBC convertible bond has been overpriced, resulting from the underestimation of credit risk. In addition, when there is an issue of dividend, the conversion price will change in China's convertible bonds, while it does not change in the international convertible bonds. So we also empirically study the difference between the convertible bond's prices by assuming whether the conversion price changes or not.

  4. Relationship between surface area for adhesion and tensile bond strength--evaluation of a micro-tensile bond test.

    Science.gov (United States)

    Sano, H; Shono, T; Sonoda, H; Takatsu, T; Ciucchi, B; Carvalho, R; Pashley, D H

    1994-07-01

    The purpose of this study was to test the null hypothesis that there is no relationship between the bonded surface area of dentin and the tensile strength of adhesive materials. The enamel was removed from the occlusal surface of extracted human third molars, and the entire flat surface was covered with resin composite bonded to the dentin to form a flat resin composite crown. Twenty-four hours later, the bonded specimens were sectioned parallel to the long axis of the tooth into 10-20 thin sections whose upper part was composed of resin composite with the lower half being dentin. These small sections were trimmed using a high speed diamond bur into an hourglass shape with the narrowest portion at the bonded interface. Surface area was varied by altering the specimen thickness and width. Tensile bond strength was measured using custom-made grips in a universal testing machine. Tensile bond strength was inversely related to bonded surface area. At surface areas below 0.4 mm2, the tensile bond strengths were about 55 MPa for Clearfil Liner Bond 2 (Kuraray Co., Ltd.), 38 MPa for Scotchbond MP (3M Dental Products), and 20 MPa for Vitremer (3M Dental Products). At these small surface areas all of the bond failures were adhesive in nature. This new method permits measurement of high bond strengths without cohesive failure of dentin. It also permits multiple measurements to be made within a single tooth.

  5. Comparative study to evaluate shear bond strength of RMGIC to composite resin using different adhesive systems

    Directory of Open Access Journals (Sweden)

    Manoj G Chandak

    2012-01-01

    Full Text Available Aim: The aim of the study is to compare and evaluate the role of new dental adhesives to bond composite to the resinmodified glass inomer cement (RMGIC. Materials and Methods: Thirty specimens were prepared on acrylic blocks, with wells prepared in it by drilling holes, to retain the RMGIC. The specimens were randomly divided into three groups of ten specimens each. In Group a thin layer of selfetch adhesive (3M ESPE was applied between the RMGIC and the composite resin FILTEK P60 (3M SPE. In Group II, total etch adhesive (Adeper Scotch bond 2, 3M ESPE was applied, and in Group III, there was no application of any adhesive between RMGIC and the composite resin. After curing all the specimens, the shear bond strength was measured using an Instron universal testing machine. Results: The results were drawn and tabulated using ANOVA-fishers and Dunnet D statistical tests.The maximum shear bond strength values were recorded in Group I specimens with self-etch adhesive showing a mean value of 2.74 when compared to the Group II adhesive (Total etch showing a mean shear strength of value 1.89, where no adhesive was used, showed a minimum mean shear bond strength of 1.42. There was a great and significant difference between Group I and Group II (P value 0.05 whereas, both Group I and Group II showed a vast and significant difference from Group III (P value = 0-001. Conclusion: Hence, this present study concludes that application of self-etch adhesive (3M ESPE, U.S.A in between RMGIC and composite resin increases the shear bond strength between RMGIC and the resin composites, as compared to the total-etch type adhesive (Adeper Scotch bond 2,3M ESPE, U.S.A as well as without application of the adhesive agent.

  6. 29 CFR 2580.412-19 - Term of the bond, discovery period, other bond clauses.

    Science.gov (United States)

    2010-07-01

    ... SECURITY ACT OF 1974 TEMPORARY BONDING RULES General Bond Rules § 2580.412-19 Term of the bond, discovery... 29 Labor 9 2010-07-01 2010-07-01 false Term of the bond, discovery period, other bond clauses... new bond must be obtained each year. There is nothing in the Act that prohibits a bond for a term...

  7. Nonperfect synchronization of bond-forming and bond-rupturing processes in the reaction H + H2 → H2 + H

    International Nuclear Information System (INIS)

    Chandra, A.K.; Rao, V.S.

    1996-01-01

    The simplest prototypical hydrogen transfer reaction, i.e., H + H 2 → H 2 + H, is studied by the quantum-mechanical ab initio methods. Results reveal that during this reaction free valence which almost equals the square of the spin density develops on the migrating hydrogen atom. Bond orders are calculated using Mayer's formalism. Both the variations of bond orders and bond lengths along the reaction path are examined. This analysis reveals that the bond formation and bond cleavage processes in this reaction are not perfectly synchronous. The bond clevage process is slightly more advanced on the reaction path. 38 refs., 6 figs., 2 tabs

  8. Shear Bond Strength of Three Orthodontic Bonding Systems on Enamel and Restorative Materials

    Directory of Open Access Journals (Sweden)

    Andreas Hellak

    2016-01-01

    Full Text Available Objective. The aim of this in vitro study was to determine the shear bond strength (SBS and adhesive remnant index (ARI score of two self-etching no-mix adhesives (iBond™ and Scotchbond™ on different prosthetic surfaces and enamel, in comparison with the commonly used total etch system Transbond XT™. Materials and Methods. A total of 270 surfaces (1 enamel and 8 restorative surfaces, n=30 were randomly divided into three adhesive groups. In group 1 (control brackets were bonded with Transbond XT primer. In the experimental groups iBond adhesive (group 2 and Scotchbond Universal adhesive (group 3 were used. The SBS was measured using a Zwicki 1120™ testing machine. The ARI and SBS were compared statistically using the Kruskal–Wallis test (P≤0.05. Results. Significant differences in SBS and ARI were found between the control group and experimental groups. Conclusions. Transbond XT showed the highest SBS on human enamel. Scotchbond Universal on average provides the best bonding on all other types of surface (metal, composite, and porcelain, with no need for additional primers. It might therefore be helpful for simplifying bonding in orthodontic procedures on restorative materials in patients. If metal brackets have to be bonded to a metal surface, the use of a dual-curing resin is recommended.

  9. Investigation of ball bond integrity for 0.8 mil (20 microns) diameter gold bonding wire on low k die in wire bonding technology

    Science.gov (United States)

    Kudtarkar, Santosh Anil

    Microelectronics technology has been undergoing continuous scaling to accommodate customer driven demand for smaller, faster and cheaper products. This demand has been satisfied by using novel materials, design techniques and processes. This results in challenges for the chip connection technology and also the package technology. The focus of this research endeavor was restricted to wire bond interconnect technology using gold bonding wires. Wire bond technology is often regarded as a simple first level interconnection technique. In reality, however, this is a complex process that requires a thorough understanding of the interactions between the design, material and process variables, and their impact on the reliability of the bond formed during this process. This research endeavor primarily focused on low diameter, 0.8 mil thick (20 mum) diameter gold bonding wire. Within the scope of this research, the integrity of the ball bond formed by 1.0 mil (25 mum) and 0.8 mil (20 mum) diameter wires was compared. This was followed by the evaluation of bonds formed on bond pads having doped SiO2 (low k) as underlying structures. In addition, the effect of varying the percentage of the wire dopant, palladium and bonding process parameters (bonding force, bond time, ultrasonic energy) for 0.8 mil (20 mum) bonding wire was also evaluated. Finally, a degradation empirical model was developed to understand the decrease in the wire strength. This research effort helped to develop a fundamental understanding of the various factors affecting the reliability of a ball bond from a design (low diameter bonding wire), material (low k and bonding wire dopants), and process (wire bonding process parameters) perspective for a first level interconnection technique, namely wire bonding. The significance of this research endeavor was the systematic investigation of the ball bonds formed using 0.8 mil (20 microm) gold bonding wire within the wire bonding arena. This research addressed low k

  10. Tensile bond strength of metal bracket bonding to glazed ceramic surfaces with different surface conditionings.

    Science.gov (United States)

    Akhoundi, Ms Ahmad; Kamel, M Rahmati; Hashemi, Sh Mahmood; Imani, M

    2011-01-01

    The objective of this study was to compare the tensile bond strength of metal brackets bonding to glazed ceramic surfaces using three various surface treatments. Forty two glazed ceramic disks were assigned to three groups. In the first and second groups the specimens were etched with 9.5% hydrofluoric acid (HFA). Subsequently in first group, ceramic primer and adhesive were applied, but in second group a bonding agent alone was used. In third group, specimens were treated with 35% phosphoric acid followed by ceramic primer and adhesive application. Brackets were bonded with light cure composites. The specimens were stored in distilled water in the room temperature for 24 hours and thermocycled 500 times between 5°C and 55°C. The universal testing machine was used to test the tensile bond strength and the adhesive remenant index scores between three groups was evaluated. The data were subjected to one-way ANOVA, Tukey and Kruskal-Wallis tests respectively. The tensile bond strength was 3.69±0.52 MPa forfirst group, 2.69±0.91 MPa for second group and 3.60±0.41 MPa for third group. Group II specimens showed tensile strength values significantly different from other groups (Ptensile bond strength.

  11. Fibre-matrix bond strength studies of glass, ceramic, and metal matrix composites

    Science.gov (United States)

    Grande, D. H.; Mandell, J. F.; Hong, K. C. C.

    1988-01-01

    An indentation test technique for compressively loading the ends of individual fibers to produce debonding has been applied to metal, glass, and glass-ceramic matrix composites; bond strength values at debond initiation are calculated using a finite-element model. Results are correlated with composite longitudinal and interlaminar shear behavior for carbon and Nicalon fiber-reinforced glasses and glass-ceramics including the effects of matrix modifications, processing conditions, and high-temperature oxidation embrittlement. The data indicate that significant bonding to improve off-axis and shear properties can be tolerated before the longitudinal behavior becomes brittle. Residual stress and other mechanical bonding effects are important, but improved analyses and multiaxial interfacial failure criteria are needed to adequately interpret bond strength data in terms of composite performance.

  12. Study of diffusion bonding in 6061 aluminum and development of future high-density fuels fabrication

    International Nuclear Information System (INIS)

    Prokofiev, I.G.; Wiencek, T.C.; McGann, D.J.

    1997-01-01

    Powder metallurgy dispersions of uranium alloys and silicides in an aluminum matrix have been developed by the RERTR program as a new generation of proliferation-resistant fuels. Testing uses fuel miniplates to simulate standard fuel with cladding and matrix in plate-type configurations. In order to seal the dispersion fuel plates, a diffusion bond must be established between the aluminum cover plates that surround the fuel meat. Four different variations of the standard method for roll-bonding 6061 aluminum were studied: mechanical cleaning, addition of a getter material, modifications to the standard chemical etching, and modifications to welding. Aluminum test pieces were subjected to a bend test after each rolling pass. Results, based on 400 samples, indicate that a reduction in thickness of at least 70% is required to produce a diffusion bond with the standard roll-bonding method, versus a 60% reduction when using a method in which the assembly was 100% welded and contained empty 9 mm holes near the frame corners. (author)

  13. Are Stock and Corporate Bond Markets Integrated?

    NARCIS (Netherlands)

    van Zundert, J.; Driessen, Joost

    2017-01-01

    This study explores the cross-sectional integration of stock and corporate bond markets by comparing a firm’s expected stock return, as implied by corporate bond spreads, to its realized stock return. We compute expected corporate bond returns by correcting credit spreads for expected losses due to

  14. Study of a class of photovoltaic systems using a bond graph approach. Modeling, analysis and control; Etude d'une classe de systemes photovoltaiques par une approche bond graph. Modelisation, analyse et commande

    Energy Technology Data Exchange (ETDEWEB)

    Andoulsi, R.

    2001-12-01

    We present in this thesis a study of a class of photovoltaic system by a bond graph approach. This study concerns the modelling, the analysis and the control of some configurations including PV generator, DC/DC converters and DC motor-pumps. The modelling of the different elements of a photovoltaic system is an indispensable stage that must precede all application of sizing, identification or simulation. However, theses PV systems are of hybrid type and their modelling is complex. It is why we use a unified modelling approach based on the bond graph technique. This methodology is completely systematic and has a sufficient flexibility for allowing the introduction of different components in the system. In the first chapter, we recall the principle of functioning of a photovoltaic generator and we treat mainly the MPPT (Maximum Power Point Tracking) working. In the second chapter, we elaborate bond graph models of various photovoltaic system configurations. For the PV source, we elaborate, in a first stage, a complete model taking into account the various physical phenomena influencing the quality of the PV source. In a second stage, we deduce a reduced bond graph model more easy to use for analysis and control purposes. For the DC/DC converters, we recall the bond graph modelling of switching elements and the average bond graph of the DC/DC converters developed in the literature. Thus, we deduce the bond graphs models of the various DC/DC converters to be used. The third chapter presents a dynamic study of some configurations stability in linear procedure. In the fourth chapter, we study the feasibility of non linear controllers by input/output linearization for some configurations of PV systems. In this study, we use the concept of inverse bond graph to determine, by a bond graph approach, the expression of the control input and the nature of the stability of the internal dynamics (dynamics of zeros). The fifth chapter is dedicated for the presentation of some

  15. Bonding Durability of Four Adhesive Systems

    Directory of Open Access Journals (Sweden)

    Leila Atash Biz Yeganeh

    2016-04-01

    Full Text Available Objectives: This study aimed to compare the durability of four adhesive systems by assessing their microtensile bond strength (MTBS and microleakage during six months of water storage.Materials and Methods: A total of 128 human third molars were used. The adhesives tested were Scotch Bond Multipurpose (SBMP, Single Bond (SB, Clearfil-SE bond (CSEB, and All-Bond SE (ABSE. After sample preparation for MTBS testing, the microspecimens were subjected to microtensile tester after one day and six months of water storage. For microleakage evaluation, facial and lingual class V cavities were prepared and restored with composite. After thermocycling, microleakage was evaluated. Bond strength values were subjected to one-way ANOVA and Tamhane’s test, and the microleakage data were analyzed by the Kruskal-Wallis, Dunn, Mann Whitney and Wilcoxon tests (P<0.05.Results: Single Bond yielded the highest and ABSE yielded the lowest bond strength at one day and six months. Short-term bond strength of SBMP and CSEB was similar. After six months, a significant decrease in bond strength was observed in ABSE and SBMP groups. At one day, ABSE showed the highest microleakage at the occlusal margin; however, at the gingival margin, there was no significant difference among groups. Long-term microleakage of all groups at the occlusal margins was similar, whilst gingival margins of SBMP and SB showed significantly higher microleakage.Conclusion: The highest MTBS and favorable sealability were obtained by Clearfil SE bond. Water storage had no effect on microleakage of self-etch adhesives at the gingival margin or MTBS of CSEB and SB. 

  16. Bond Portfolio Allocations in South Africa Emerging Markets

    Directory of Open Access Journals (Sweden)

    Jinghua Wang

    2016-03-01

    Full Text Available Over the past fifty years, economic growth in emerging markets has been supported by investments in capital and technology from the developed world. The benefit of this development for the emerging markets, as measured by growth in income, employment, and wealth, is immediately apparent. There have also been significant advantages for the developed world through opportunities for higher risk adjusted returns from investments in emerging markets. This study explores the benefits of the diversification of global government bond portfolio, and provides complete performance evaluations of DMs with or without South Africa emerging market (SAEM bonds. The study examines the benefits of inclusion of SAEM bonds in DMs, the degrees of financial integration among the research markets, the relative bond returns of dynamic factor models with time-varying coefficients and the robust tests of bond portfolio performance between DMs with SAEM and bond index. The results of this study provide important implications for global investors by identifying diversification gains in SAEM.  Keywords: African Bond Market, Portfolio Diversification

  17. Announcement effects of convertible bond loans versus warrant-bond loans : An empirical analysis for the Dutch market

    NARCIS (Netherlands)

    de Roon, F.A.; Veld, C.H.

    1995-01-01

    This study investigates the announcement effects of offerings of convertible bond loans and warrant-bond loans using data for the Dutch market. Using standard event study methodology it is found that on average stock prices show a positive but insignificant abnormal return for the announcement of a

  18. Cooperativity in Surface Bonding and Hydrogen Bonding of Water and Hydroxyl at Metal Surfaces

    DEFF Research Database (Denmark)

    Schiros, T.; Ogasawara, H.; Naslund, L. A.

    2010-01-01

    of the mixed phase at metal surfaces. The surface bonding can be considered to be similar to accepting a hydrogen bond, and we can thereby apply general cooperativity rules developed for hydrogen-bonded systems. This provides a simple understanding of why water molecules become more strongly bonded...... to the surface upon hydrogen bonding to OH and why the OH surface bonding is instead weakened through hydrogen bonding to water. We extend the application of this simple model to other observed cooperativity effects for pure water adsorption systems and H3O+ on metal surfaces.......We examine the balance of surface bonding and hydrogen bonding in the mixed OH + H2O overlayer on Pt(111), Cu(111), and Cu(110) via density functional theory calculations. We find that there is a cooperativity effect between surface bonding and hydrogen bonding that underlies the stability...

  19. Intermolecular hydrogen bonds: From temperature-driven proton ...

    Indian Academy of Sciences (India)

    Abstract. We have combined neutron scattering and a range of numerical simulations to study hydrogen bonds in condensed matter. Two examples from a recent thesis will be presented. The first concerns proton transfer with increasing temperature in short inter- molecular hydrogen bonds [1,2]. These bonds have unique ...

  20. Evaluation of microtensile bond strength of total-etch, self-etch, and glass ionomer adhesive to human dentin: An in vitro study

    Directory of Open Access Journals (Sweden)

    Neelima Lakshmi

    2008-01-01

    Full Text Available Aim: To evaluate the microtensile bond strength of Single Bond, AdheSE, and Fuji Bond LC to human dentin. Fifteen non-carious third molars were selected for the study. The teeth were randomly divided into three groups of five teeth each. Each group was given a different bonding treatment. Group I was treated with Single Bond (3M, ESPE, group II with AdheSE (Ivoclar, Vivadent, and group III was treated with Fuji Bond LC (GC America. A T-band metal matrix was placed and composite resin bonded on to the tooth surface using appropriate bonding agents. The composite resin was packed in increments and light cured. Each tooth was sectioned to obtain 1 mm x 1 mm beams of dentin-resin samples. Tensile bond testing was done using a universal testing machine (Instron at a cross-head speed of 0.5 mm/min. Results: The mean bond strength of Single Bond (35.5 MPa was significantly higher than that of AdheSE (32.8 MPa and Fuji Bond LC (32.6 MPa. The difference between the microtensile bond strength values of AdheSE and Fuji Bond LC was statistically insignificant. Inference: Though the bond strength of AdheSE and Fuji Bond LC was above 30 MPa, it was less than that of Single Bond as evaluated by testing of microtensile bond strength.

  1. A review: Biodegradation of resin–dentin bonds

    Directory of Open Access Journals (Sweden)

    Masanori Hashimoto

    2011-02-01

    Full Text Available Resin–dentin bonding was first achieved through mechanical hybridization between resin and collagen fibrils using a functional monomer containing resin system. In the last decade, new adhesive resin systems were frequently released onto the market within a short-period of time. Before and after commercialization, the bond integrity has been tested by bond tests, and leakage evaluation by researchers, but it is very difficult for clinicians to obtain a comprehensive, up-to-date understanding of their nature and degradation. Although newly developed adhesive resins have attempted to improve the bond strength at least in the first 24 h after bonding, the long-term durability of the bonds has not yet been established analytically. However, numerous recent studies have shown micromorphological evidence of biodegradation of resin–dentin bonds, due to hydrolysis of the resin and collagen fibrils within the bonds. This review mainly summarizes the most recent work in biodegradation of resin–dentin bonds based on micromorphological analyses of data obtained by scanning and transmission electron microscopy.

  2. Cervical spinal cord, root, and bony spine injuries: a closed claims analysis.

    Science.gov (United States)

    Hindman, Bradley J; Palecek, John P; Posner, Karen L; Traynelis, Vincent C; Lee, Lorri A; Sawin, Paul D; Tredway, Trent L; Todd, Michael M; Domino, Karen B

    2011-04-01

    The aim of this study was to characterize cervical cord, root, and bony spine claims in the American Society of Anesthesiologists Closed Claims database to formulate hypotheses regarding mechanisms of injury. All general anesthesia claims (1970-2007) in the Closed Claims database were searched to identify cervical injuries. Three independent teams, each consisting of an anesthesiologist and neurosurgeon, used a standardized review form to extract data from claim summaries and judge probable contributors to injury. Cervical injury claims (n = 48; mean ± SD age 47 ± 15 yr; 73% male) comprised less than 1% of all general anesthesia claims. When compared with other general anesthesia claims (19%), cervical injury claims were more often permanent and disabling (69%; P cervical stenosis) were often present, cord injuries usually occurred in the absence of traumatic injury (81%) or cervical spine instability (76%). Cord injury occurred with cervical spine (65%) and noncervical spine (35%) procedures. Twenty-four percent of cord injuries were associated with the sitting position. Probable contributors to cord injury included anatomic abnormalities (81%), direct surgical complications (24% [38%, cervical spine procedures]), preprocedural symptomatic cord injury (19%), intraoperative head/neck position (19%), and airway management (11%). Most cervical cord injuries occurred in the absence of traumatic injury, instability, and airway difficulties. Cervical spine procedures and/or sitting procedures appear to predominate. In the absence of instability, cervical spondylosis was the most common factor associated with cord injury.

  3. Comparative Evaluation of shear Bond Strength of universal Dental Adhesives -An in vitro study.

    Science.gov (United States)

    Jayasheel, Arun; Niranjan, Nandini; Pamidi, Hemanthkumar; Suryakanth, Mayuri B

    2017-07-01

    Patient demand for tooth colored restorations and desire for minimally invasive restorations have made composites an indispensable part of the restorative process. An important factor affecting the intra-oral performance of composite restorations is bonding. Ninty six freshly extracted molar teeth were collected and occlusal 3mm is removed using a diamond disc to expose dentine. Following with samples were divided in to two main groups (self-etch & total etch). Each main group is again sub divided in to three groups each according to bonding agent used (Tetric N- Bond Universal, Single Bond Universal, Tetric N Bond Total etch in total etch group and Clear Fill SE in self etch group). Following which bonding protocol is followed according to manufacture instructions, a composite buildup of 2x3 mm is done on each specimen and then specimen were subjected to shear bond test under universal testing machine. All the readings were noted and subjected to statistical analysis using One way ANOVA and Tukey's posthoc test. It showed that there is no significant difference among the groups in both self-etch and total etch modes. It can be concluded that application of an etching step prior to Universal Adhesives significantly improves their dentine penetration pattern, although this does not affect their mean SBS. The bond strength values of the TBU regardless of application mode were comparable to SBU making them reliable for working under different clinical conditions. Key words: Dentine bonding agents, self-etch mode, total etch mode, shear bond strength.

  4. Effect of solvent on proton location and dynamic behavior in short intramolecular hydrogen bonds studied by molecular dynamics simulations and NMR experiments

    International Nuclear Information System (INIS)

    Mori, Yukie; Masuda, Yuichi

    2015-01-01

    Highlights: • MD simulations were performed to study dynamics of strong hydrogen bonds. • Nuclear magnetic relaxation times of proton were measured in solution. • The hydrogen bond of dibenzoylmethane enol is asymmetric in methanol solution. • Formation or breakage of intermolecular hydrogen bonds can trigger proton transfer. • Dimethylsulfoxide may form a bifurcated hydrogen bond with a hydrogen-bonded system. - Abstract: Hydrogen phthalate anion has a short strong O–H–O hydrogen bond (H-bond). According to previous experimental studies, the H-bond is asymmetric and two tautomers are interconverted in aqueous solutions. In the present study, the effects of polar solvents on the H-bond in a zwitterionic hydrogen phthalate derivative 1 were investigated by quantum mechanics/molecular mechanics molecular dynamics (MD) simulations. The analyses of the trajectories for the methanol solution showed that the H-bonding proton tends to be located closer to the carboxylate group that forms fewer intermolecular H-bonds, than to the other carboxylate group and that the intramolecular proton transfer in 1 is triggered by the breakage and/or formation of an intermolecular H-bond. The enol form of dibenzoylmethane (2) also has a short H-bond, and the OH bond is reported to be rather long (>1.1 Å) in the crystal. In the present study, the effects of the solvent on the H-bond in 2 were investigated by molecular orbital (MO) calculations, MD simulations and nuclear magnetic resonance (NMR) spectroscopy. Density functional theory (DFT) calculations for 2 in vacuum indicated that the barrier height for the intramolecular proton transfer is almost the same as the zero-point energy of the vibrational ground state, resulting in broad distribution of the proton density along the H-bond, owing to the nuclear quantum effect. The OH distances were determined in CCl 4 , acetonitrile, and dimethylsulfoxide solutions from the magnetic dipolar interactions between the 17 O and 1

  5. Effect of solvent on proton location and dynamic behavior in short intramolecular hydrogen bonds studied by molecular dynamics simulations and NMR experiments

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Yukie, E-mail: mori.yukie@ocha.ac.jp; Masuda, Yuichi

    2015-09-08

    Highlights: • MD simulations were performed to study dynamics of strong hydrogen bonds. • Nuclear magnetic relaxation times of proton were measured in solution. • The hydrogen bond of dibenzoylmethane enol is asymmetric in methanol solution. • Formation or breakage of intermolecular hydrogen bonds can trigger proton transfer. • Dimethylsulfoxide may form a bifurcated hydrogen bond with a hydrogen-bonded system. - Abstract: Hydrogen phthalate anion has a short strong O–H–O hydrogen bond (H-bond). According to previous experimental studies, the H-bond is asymmetric and two tautomers are interconverted in aqueous solutions. In the present study, the effects of polar solvents on the H-bond in a zwitterionic hydrogen phthalate derivative 1 were investigated by quantum mechanics/molecular mechanics molecular dynamics (MD) simulations. The analyses of the trajectories for the methanol solution showed that the H-bonding proton tends to be located closer to the carboxylate group that forms fewer intermolecular H-bonds, than to the other carboxylate group and that the intramolecular proton transfer in 1 is triggered by the breakage and/or formation of an intermolecular H-bond. The enol form of dibenzoylmethane (2) also has a short H-bond, and the OH bond is reported to be rather long (>1.1 Å) in the crystal. In the present study, the effects of the solvent on the H-bond in 2 were investigated by molecular orbital (MO) calculations, MD simulations and nuclear magnetic resonance (NMR) spectroscopy. Density functional theory (DFT) calculations for 2 in vacuum indicated that the barrier height for the intramolecular proton transfer is almost the same as the zero-point energy of the vibrational ground state, resulting in broad distribution of the proton density along the H-bond, owing to the nuclear quantum effect. The OH distances were determined in CCl{sub 4}, acetonitrile, and dimethylsulfoxide solutions from the magnetic dipolar interactions between the {sup 17

  6. Bond lengths and bond strengths in compounds of the 5f elements

    International Nuclear Information System (INIS)

    Zachariasen, W.H.

    1975-01-01

    The variation of bond length (D) with bond strength (S) in normal valence compounds of 3d, 4d, 5d-4f, and 6d-5f elements can be represented approximately as D(S)=D(0.5) F(S), where D(0.5) is a characteristic constant for a given bond and F(S) an empirical function which is the same for all bonds. A bond strength Ssub(ij)=ssub(ji) is assigned to the bond between atoms i and j such that Σsub(j) Ssub(ij)=vsub(i) and Σsub(i) Ssub(ij)=vsub(j), where vsub(i) and vsub(j) are the normal valences of the two atoms. The function F(S) decreases monotonically with increasing S, and is normalized to unity at S=0.5, so that the constant D(0.5) has the physical meaning of being the bond length adjusted to S=0.5. The method described above was used to interpret and systematize the experimental results on bond lengths in oxides, halides, and oxyhalides of the 5f elements. (U.S.)

  7. An evaluation of shear bond strength of self-etch adhesive on pre-etched enamel: an in vitro study.

    Science.gov (United States)

    Rao, Bhadra; Reddy, Satti Narayana; Mujeeb, Abdul; Mehta, Kanchan; Saritha, G

    2013-11-01

    To determine the shear bond strength of self-etch adhesive G-bond on pre-etched enamel. Thirty caries free human mandibular premolars extracted for orthodontic purpose were used for the study. Occlusal surfaces of all the teeth were flattened with diamond bur and a silicon carbide paper was used for surface smoothening. The thirty samples were randomly grouped into three groups. Three different etch systems were used for the composite build up: group 1 (G-bond self-etch adhesive system), group 2 (G-bond) and group 3 (Adper single bond). Light cured was applied for 10 seconds with a LED unit for composite buildup on the occlusal surface of each tooth with 8 millimeters (mm) in diameter and 3 mm in thickness. The specimens in each group were tested in shear mode using a knife-edge testing apparatus in a universal testing machine across head speed of 1 mm/ minute. Shear bond strength values in Mpa were calculated from the peak load at failure divided by the specimen surface area. The mean shear bond strength of all the groups were calculated and statistical analysis was carried out using one-way Analysis of Variance (ANOVA). The mean bond strength of group 1 is 15.5 Mpa, group 2 is 19.5 Mpa and group 3 is 20.1 Mpa. Statistical analysis was carried out between the groups using one-way ANOVA. Group 1 showed statistically significant lower bond strength when compared to groups 2 and 3. No statistical significant difference between groups 2 and 3 (p adhesive G-bond showed increase in shear bond strength on pre-etched enamel.

  8. El epítome floreado de los comentarios de Caio Julio César de Carlos Bonyères

    OpenAIRE

    Fernández-Savater Martín, María Victoria; Conde Salazar, Matilde

    2005-01-01

    El presente estudio tiene como objetivo principal el examen del Epítome floreado de los Comentarii de Caio Iulio César, que escribió en castellano el francés Carlos de Bonyéres, a fin de intentar determinar sus fuentes y su posible relación con otros comentarios de la obra cesariana. Tras una lectura detenida, se comprueba que dicha obra es un resumen de la obra de César y no tiene similitud alguna con otros comentarios de César en castellano, en especial con los de Diego Gracián y Gabriel Si...

  9. Prospective associations between recalled parental bonding and perinatal depression: a cohort study in urban and rural Turkey.

    Science.gov (United States)

    Duman, Berker; Senturk Cankorur, Vesile; Taylor, Clare; Stewart, Robert

    2018-04-01

    Recalled experiences of parental bonding may be important in the aetiology of perinatal depression. We hypothesized that lower recalled parental bonding would be associated with perinatal depression. In a cohort study of perinatal depression in Turkey, 677 women were recruited in their third trimester. Parental Bonding Inventory (PBI) scores at baseline were investigated as predictors of depression on the Edinburgh Postnatal Depression Scale (EPDS) at 4, 14 and 21 months after childbirth in mothers without depression at baseline. Poor parental bonding scores, apart from paternal control and overprotection, were independently associated with antenatal depression. Incident postnatal depression at 4 months was predicted by parental overprotection, at 14 months by parental care and overprotection, and at 21 months by paternal control and overprotection. Less satisfactory parenting recalled in the antenatal period was an independent predictor of postnatal depression; however, the different bonding subscales varied as predictors according to the timing of the depression assessment after childbirth.

  10. Evaluation of the anti-cariogenic potential and bond strength to enamel of different fluoridated materials used for bracket bonding

    OpenAIRE

    SILVA, Sérgio Ricardo da; SILVA, Luciana Alves Herdy da; BASTING, Roberta Tarkany; LIMA-ARSATI, Ynara Bosco de Oliveira

    2017-01-01

    Abstract Objective To evaluate the in vitro and in situ anti-cariogenic potential and bond strength to enamel of materials containing fluoride (F), used for bracket bonding: Transbond XT (GT, negative control), Transbond Plus Color Change (GTF), Transbond-Self-Etching Primer (GSAF) and Vitremer (GV, positive control). Material and method In the in vitro study, the specimens were premolars with bonded brackets (n=12/group). After pH cycling, the F release, bond strength, fracture mode and pr...

  11. Voltage-assisted polymer wafer bonding

    International Nuclear Information System (INIS)

    Varsanik, J S; Bernstein, J J

    2012-01-01

    Polymer wafer bonding is a widely used process for fabrication of microfluidic devices. However, best practices for polymer bonds do not achieve sufficient bond strength for many applications. By applying a voltage to a polymer bond in a process called voltage-assisted bonding, bond strength is shown to improve dramatically for two polymers (Cytop™ and poly(methyl methacrylate)). Several experiments were performed to provide a starting point for further exploration of this technique. An optimal voltage range is experimentally observed with a reduction in bonding strength at higher voltages. Additionally, voltage-assisted bonding is shown to reduce void diameter due to bond defects. An electrostatic force model is proposed to explain the improved bond characteristics. This process can be used to improve bond strength for most polymers. (paper)

  12. The bond between school-age children and their dogs, and the socioemotional effects of this bond

    Directory of Open Access Journals (Sweden)

    Claudia Schencke

    2012-08-01

    Full Text Available Numerous international studies have proved that owning a pet can enhance the quality of life of school-age children; however, there have been no such studies in Chile. The objective of the present study is to analyzes the bond between school-age children and their dogs, and the socioemotional effects of such bond, in particular as it relates to self-identity and the perception of social support. Some differences appear in the results of international studies, in the sense that no significant difference can be observed in terms of self-identity or perceived social support between children who own a dog and children who don’t. However, it is significant that children who perceive themselves as unpopular have a stronger bond with their pets than those who perceive themselves as popular.

  13. Municipal Bonds in Developing Countries. Case Study: Municipality of Stip, Republic of Macedonia

    Directory of Open Access Journals (Sweden)

    Marija GOGOVA SAMONIKOV

    2017-06-01

    Full Text Available The developing countries, especially in the Balkans, barely use the municipal bonds as an alternative way of financing their activities. This paper is part of the project “The municipal bonds as an alternative source of financing municipals activities and the effective management of funds, with a special emphasis to the Municipality of Stip, R. Macedonia”. The paper has an important impact, according to both academic and practical perspective. It combines the experts’ academic analysis with the municipals potential in order to facilitate a successful municipal bond emission that would support the local economic growth. The purpose of this paper is to investigate the ability and willingness of the Municipality of Stip to issue municipal bonds. The main hypothesis states that the Municipality of Stip is able to issue a municipal bond as an alternative way of financing its investment activities. The research includes the classical SWOT analysis regarding the Municipality of Stip and continues with a statistical analysis based on correlation and regression relationships within the accounts of the Municipality’s annual reports. The methodological framework is based on quantitative research methods (correlations and regression methods which result in acceptance of the main hypothesis in the paper - the municipal bonds as an alternative source for funding municipal’s activities are justified, especially if the funds are associated with a specific revenue-generating project. The findings would serve as a basis for the municipal bonds prospect, which would be the ultimate goal of combining the academic knowledge with the practical potential of the Municipality of Stip. The conclusions reveal that this would be the first municipal bond emission in the Republic of Macedonia. However, this fact can serve as an advantage in the market in terms of introducing financial instrument innovation. This paper suggests that the usage of municipal bonds is

  14. Analytical and numerical study concerning the behaviour of single-sided bonded patch repairs

    Directory of Open Access Journals (Sweden)

    Gheorghi OPATCHI

    2011-06-01

    Full Text Available Adhesive bonded joints are used in the assembling of structural parts, especially of those which are made from dissimilar materials. Lightweight fibre reinforced polymer composites and other adhesive bonded components represent a major proportion of a modern aircraft. Bonded patch repair technology has been widely used to repair cracked thin-walled structures to extend their service life, because a correctly executed repair significantly enhances the structural performance.In practice, the single-sided bonded patch repair is the most used because a good solution like the double-sided repair may not be an option if the access to the structure is only available from one side.This paper presents a relatively simple and effective design procedure for the single strapped bonded joints. Also, the influence of various geometrical parameters of the joint is evaluated. The analytical development is validated based on nonlinear finite element analyses.

  15. Evaluation of shear bond strength of orthodontic brackets bonded with nano-filled composites.

    Science.gov (United States)

    Chalipa, Javad; Akhondi, Mohammad Sadegh Ahmad; Arab, Sepideh; Kharrazifard, Mohammad Javad; Ahmadyar, Maryam

    2013-09-01

    The purpose of this study was to evaluate the shear bond strength (SBS) of orthodontic brackets bonded with two types of nano-composites in comparison to a conventional orthodontic composite. Sixty extracted human first premolars were randomly divided into 3 groups each containing 20 teeth. In group I, a conventional orthodontic composite (Transbond XT) was used to bond the brackets, while two nano-composites (Filtek TM Supreme XT and AELITE Aesthetic Enamel) were used in groups II and III respectively. The teeth were stored in distilled water at 37°C for 24 hours, thermocycled in distilled water and debonded with a universal testing machine at a crosshead speed of 1 mm/min. The adhesive remnant index (ARI) was also evaluated using a stereomicroscope. AELITE Aesthetic Enamel nano-composite revealed a SBS value of 8.44±2.09 MPa, which was higher than Transbond XT (6.91±2.13) and Filtek TM Supreme XT (6.04±2.01). Statistical analysis revealed a significant difference between groups II and III (P 0.05). Evaluation of ARI showed that Transbond XT left fewer adhesive remains on teeth after debonding. Results of this study indicate that the aforementioned nano-composites can be successfully used for bonding orthodontic brackets.

  16. Effect of Delayed Bonding and Antioxidant Application on the Bond Strength to Enamel after Internal Bleaching.

    Science.gov (United States)

    Kılınç, Halil İbrahim; Aslan, Tuğrul; Kılıç, Kerem; Er, Özgür; Kurt, Gökmen

    2016-07-01

    This study evaluated the effect of delayed bonding and antioxidant application (AA, 10% sodium ascorbate) after internal bleaching (35% carbamide peroxide) on the shear bond strength of an adhesive cement to enamel. Eighty-four human maxillary central incisors were endodontically treated. The control group remained unbleached with no AA. Experimental groups were all internally bleached. The buccal enamel was finished and polished with metallographic paper to a refinement of #600, in order to obtain a 5-mm(2) flat bonding area. An adhesive cement (Clearfil Esthetic) was placed into a plastic tube with internal diameter of 3 mm and a 3-mm height and cured on the enamel. Bonding occurred either immediately after bleaching (group Im), a 7-day delay (group 7), or a 14-day delay (group 14), and half the specimens were treated with antioxidant application (groups Im-AA, 7-AA, and 14-AA). Shear bond strength testing was performed on a universal testing machine, and data were analyzed with ANOVA and Fisher test (5%). Delaying of bonding is a useful factor for enhancing shear bond strength (p adhesive cementation to enamel is recommended only when delayed 14 days, or delayed 7 days with sodium ascorbate application. © 2015 by the American College of Prosthodontists.

  17. A contribution to the study of metal-ceramic bonding by direct vacuum brazing with reactive metals

    International Nuclear Information System (INIS)

    Guimaraes, A.S.

    1988-01-01

    Wettability and bonding tests were utilized to evaluate the behaviour of various specials alloys, for work at high temperature under vacuum, for the inter-bonding of silicon carbide, alumina ceramic, graphite (for electrical applications) and petroleum coke and their joining with themselves as the metals titanium, molybdenum, nickel and copper. The joints exhibiting effective bonding were investigated by means of optical microscopy, scanning electron microscopy and X-rays diffraction. Elemental mapping of the constituents and quantitative chemical microanalysis were also undertaken, via the energy dispersive analysis of X-rays (SEM/EDS). On the basis of the results the possible mechanisms of bond-formation have been discussed. It was verified that: a) of the filler metals studied, those which exhibited effective wettability on all the above materials were: 49Cu-49Ti-2Be, Zircaloy4-5Be and a commercial alloy Ticusil, which consisted of a Cu-Ag eutectic with a small addition of pure Ti, of nominal composition 26.7Cu-68.8Ag-4.5Ti; b) the alloys with high levels of reactive metals such as Ti and Zr tended to form low ductility bonds due to the formation of hard, brittle phases; c) the copper suffered pronounced erosion when in direct contact with alloys of high Ti and Zr contents, due to the formation of phases whose melting points were below the brazing temperature of those materials; e) the compounds detected as reaction products were identified as, TiC in the samples rich in carbon, such as the SiC ceramic and graphite joints, or the oxides Cu2Ti2O5 and Cu3TiO4 in the bonding of alumina to alloys including Ti in their composition or in that of the filler metal, proving that the effectiveness of the bond is dependent upon an initial and indispensable chemical bonding. (author)

  18. 30 CFR 281.33 - Bonds and bonding requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Bonds and bonding requirements. 281.33 Section 281.33 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE LEASING OF MINERALS OTHER THAN OIL, GAS, AND SULPHUR IN THE OUTER CONTINENTAL SHELF Financial Considerations § 281.33...

  19. Synthesis, spectroscopic characterization and structural studies of a new proton transfer (H-bonded) complex of o-phenylenediamine with L-tartaric acid

    Science.gov (United States)

    Khan, Ishaat M.; Ahmad, Afaq

    2013-10-01

    A proton transfer or H-bonded (CT) complex of o-phenylenediamine (OPD) as donor with L-tartaric acid (TART) as acceptor was synthesized and characterized by spectral techniques such as FTIR, 1H NMR, elemental analysis, TGA-TDA, X-ray crystallography and spectrophotometric studies. The structural investigations exhibit that the cation [OPD+] and anion [TART-] are linked together through strong N+-H⋯O- type hydrogen bonds due to transfer of proton from acceptor to donor. Formed H-bonded complex exhibits well resolved proton transfer bands in the regions where neither donor nor acceptor has any absorption. The stoichiometry of the H-bonded complex (HBC) was found to be 1:1, determined by straight line methods. Spectrophotometric studies have been performed at room temperature and Benesi-Hildebrand equation was used to determine formation constant (KCT), molar extinction coefficient (ɛCT) and also transition energy (ECT) of the H-bonded complex. Spectrophotomeric and crystallographic studies have ascertained the formation of 1:1 H-bonded complex. Thermal analysis (TGA-DTA) was also used to confirm the thermal fragmentation and the stability of the synthesized H-bonded complex.

  20. Orbital Tumors Excision without Bony Marginotomy under Local and General Anesthesia

    Directory of Open Access Journals (Sweden)

    Robert A. Goldberg

    2014-01-01

    Full Text Available To present our experience of removing middle to deep orbital tumors using a combination of minimally invasive soft tissue approaches, sometimes under local anesthesia. Methods. In this retrospective case series, 30 patients (13 males and 17 females underwent tumor removal through eyelid crease (17 eyes, conjunctival (nine eyes, lateral canthal (two eyes, and transcaruncular (two eyes approaches. All tumors were located in the posterior half of the orbit. Six cases were removed under monitored anesthesia care with local block, and 24 were under general anesthesia. Results. The median (range age and follow-up duration were 48.5 (31–87 years old and 24.5 (4–375 weeks, respectively. Visual acuity and ocular motility showed improvement or no significant change in all but one patient at the latest followup. Confirmed pathologies revealed cavernous hemangioma (15 cases, pleomorphic adenoma (5 cases, solitary fibrous tumor (4 cases, neurofibroma (2 cases, schwannoma (2 cases, and orbital varix (1 case. None of the patients experienced recurrence. Conclusions. Creating a bony marginotomy increases intraoperative exposure of the deep orbit but adds substantial time and morbidity. Benign orbital tumors can often be removed safely through small soft-tissue incisions, without bone removal and under local anesthesia.

  1. Insertion reactions into Pd[bond]O and Pd[bond]N bonds: preparation of alkoxycarbonyl, carbonato, carbamato, thiocarbamate, and thioureide complexes of palladium(II).

    Science.gov (United States)

    Ruiz, José; Martínez, M Teresa; Florenciano, Félix; Rodríguez, Venancio; López, Gregorio; Pérez, José; Chaloner, Penny A; Hitchcock, Peter B

    2003-06-02

    Mononuclear palladium hydroxo complexes of the type [Pd(N[bond]N)(C(6)F(5))(OH)] [(N[bond]N = 2,2'-bipyridine (bipy), 4,4'-dimethyl-2,2'-bipyridine (Me(2)bipy), 1,10-phenanthroline (phen), or N,N,N',N'-tetramethylethylenediamine (tmeda)] have been prepared by reaction of [Pd(N[bond]N)(C(6)F(5))(acetone)]ClO(4) with KOH in methanol. These hydroxo complexes react, in methanol, with CO (1 atm, room temperature) to yield the corresponding methoxycarbonyl complexes [Pd(N[bond]N)(C(6)F(5))(CO(2)Me)]. Similar alkoxycarbonyl complexes [Pd(N[bond]N)(C(6)F(5))(CO(2)R)] (N[bond]N = bis(3,5-dimethylpyrazol-1-yl)methane); R = Me, Et, or (i)Pr) are obtained when [Pd(N[bond]N)(C(6)F(5))Cl] is treated with KOH in the corresponding alcohol ROH and CO is bubbled through the solution. The reactions of [Pd(N[bond]N)(C(6)F(5))(OH)] (N[bond]N = bipy or Me(2)bipy) with CO(2), in tetrahydrofuran, lead to the formation of the binuclear carbonate complexes [(N[bond]N)(C(6)F(5))Pd(mu-eta(2)-CO(3))Pd(C(6)F(5))(N[bond]N)]. Complexes [Pd(N[bond]N)(C(6)F(5))(OH)] react in alcohol with PhNCS to yield the corresponding N-phenyl-O-alkylthiocarbamate complexes [Pd(N[bond]N)(C(6)F(5))[SC(OR)NPh

  2. The anterior cruciate ligament: a study on its bony and soft tissue anatomy using novel 3D CT technology.

    Science.gov (United States)

    Tampere, Thomas; Van Hoof, Tom; Cromheecke, Michiel; Van der Bracht, Hans; Chahla, Jorge; Verdonk, Peter; Victor, Jan

    2017-01-01

    The purpose of this study is twofold: first, to visualize both the tibial and femoral bony insertion surfaces and second, to describe the anterior cruciate ligament (ACL) geometrically, using novel 3D CT imaging. In addition, new concepts of best-fit cylinder and central axis are introduced and evaluated. Eight unpaired knees of embalmed cadavers were used in this study. Following the dissection process, the ACL was injected with a contrast medium for CT imaging. The obtained CT images in extension, 45°, 90° and full flexion were segmented and rendered in 3D allowing morphological and morphometric analysis of the ACL. Anatomical footprint centres, femoral and tibial footprint surface area, best-fit ACL-cylinder intersection area, best-fit ACL-cylinder/footprint coverage ratio, best-fit ACL-cylinder central axis projections at the tibial and femoral footprint in the four positions were used to describe the anatomy of the ACL, based on the Bernard, Hertel and Amis grid. Based on these parameters, with the best-fit cylinder representing the bulk of the ACL, a changing fibre-recruitment pattern was seen with a moving position of the central axis from posterior to anterior on the femoral and tibial footprint, going from extension to flexion. Furthermore, the numerical data show an increase in tibial footprint coverage by the best-fit cylinder through the ACL when the knee is progressively flexed, whereas an inverse relationship was seen on the femoral side. This study is the first to describe the detailed anatomy of the human ACL with respect to its course and footprints using a 3D approach. It confirms the large difference and inter-patient variability between the tibial and femoral footprint area with the former being significantly smaller. The best-fit cylinder concept illustrates the recruitment pattern of the native ACL where in extension the postero-lateral fibres are recruited and in flexion rather the antero-medial bundle, which can be valuable information in

  3. The Nature of the Hydrogen Bond Outline of a Comprehensive Hydrogen Bond Theory

    CERN Document Server

    Gilli, Gastone

    2009-01-01

    Hydrogen bond (H-bond) effects are known: it makes sea water liquid, joins cellulose microfibrils in trees, shapes DNA into genes and polypeptide chains into wool, hair, muscles or enzymes. Its true nature is less known and we may still wonder why O-H...O bond energies range from less than 1 to more than 30 kcal/mol without apparent reason. This H-bond puzzle is re-examined here from its very beginning and presented as an inclusive compilation of experimental H-bond energies andgeometries.New concepts emerge from this analysis: new classes of systematically strong H-bonds (CAHBs and RAHBs: cha

  4. THEORETICAL AND NUMERICAL VALUATION OF CALLABLE BONDS

    OpenAIRE

    Dejun Xie

    2009-01-01

    This paper studies the value of a callable bond and the bond issuer’s optimal financial decision regarding whether to continue the investment on the market or call the bond. Assume the market investment return follows a stochastic model, the value of contract is formulated as a partial differential equation system embedded with a free boundary, defining the level of market return rate at which it is optimal for the issuer to call the bond. A fundamental solution of the partial differential ...

  5. Hydrogen bonding in ionic liquids.

    Science.gov (United States)

    Hunt, Patricia A; Ashworth, Claire R; Matthews, Richard P

    2015-03-07

    Ionic liquids (IL) and hydrogen bonding (H-bonding) are two diverse fields for which there is a developing recognition of significant overlap. Doubly ionic H-bonds occur when a H-bond forms between a cation and anion, and are a key feature of ILs. Doubly ionic H-bonds represent a wide area of H-bonding which has yet to be fully recognised, characterised or explored. H-bonds in ILs (both protic and aprotic) are bifurcated and chelating, and unlike many molecular liquids a significant variety of distinct H-bonds are formed between different types and numbers of donor and acceptor sites within a given IL. Traditional more neutral H-bonds can also be formed in functionalised ILs, adding a further level of complexity. Ab initio computed parameters; association energies, partial charges, density descriptors as encompassed by the QTAIM methodology (ρBCP), qualitative molecular orbital theory and NBO analysis provide established and robust mechanisms for understanding and interpreting traditional neutral and ionic H-bonds. In this review the applicability and extension of these parameters to describe and quantify the doubly ionic H-bond has been explored. Estimating the H-bonding energy is difficult because at a fundamental level the H-bond and ionic interaction are coupled. The NBO and QTAIM methodologies, unlike the total energy, are local descriptors and therefore can be used to directly compare neutral, ionic and doubly ionic H-bonds. The charged nature of the ions influences the ionic characteristics of the H-bond and vice versa, in addition the close association of the ions leads to enhanced orbital overlap and covalent contributions. The charge on the ions raises the energy of the Ylp and lowers the energy of the X-H σ* NBOs resulting in greater charge transfer, strengthening the H-bond. Using this range of parameters and comparing doubly ionic H-bonds to more traditional neutral and ionic H-bonds it is clear that doubly ionic H-bonds cover the full range of weak

  6. Bond-Slip Relationship for CFRP Sheets Externally Bonded to Concrete under Cyclic Loading.

    Science.gov (United States)

    Li, Ke; Cao, Shuangyin; Yang, Yue; Zhu, Juntao

    2018-02-26

    The objective of this paper was to explore the bond-slip relationship between carbon fiber-reinforced polymer (CFRP) sheets and concrete under cyclic loading through experimental and analytical approaches. Modified beam tests were performed in order to gain insight into the bond-slip relationship under static and cyclic loading. The test variables are the CFRP-to-concrete width ratio, and the bond length of the CFRP sheets. An analysis of the test results in this paper and existing test results indicated that the slope of the ascending segment of the bond-slip curve decreased with an increase in the number of load cycles, but the slip corresponding to the maximum shear stress was almost invariable as the number of load cycles increased. In addition, the rate of reduction in the slope of the ascending range of the bond-slip curve during cyclic loading decreased as the concrete strength increased, and increased as the load level or CFRP-to-concrete width ratio enhanced. However, these were not affected by variations in bond length if the residual bond length was longer than the effective bond length. A bilinear bond-slip model for CFRP sheets that are externally bonded to concrete under cyclic loading, which considered the effects of the cyclic load level, concrete strength, and CFRP-to-concrete ratio, was developed based on the existing static bond-slip model. The accuracy of this proposed model was verified by a comparison between this proposed model and test results.

  7. One period coupon bond valuation with revised first passage time approach and the application in Indonesian corporate bond

    Science.gov (United States)

    Maruddani, Di Asih I.; Rosadi, Dedi; Gunardic, Abdurakhman

    2015-02-01

    The value of a corporate bond is conventionally expressed in terms of zero coupon bond. In practice, the most common form of debt instrument is coupon bond and allows early default before maturity as safety covenant for the bondholder. This paper study valuation for one period coupon bond, a coupon bond that only give one time coupon at the bond period. It assumes that the model give bondholder the right to reorganize a firm if its value falls below a given barrier. Revised first passage time approach is applied for default time rule. As a result, formulas of equity, liability, and probability of default is derived for this specified model. Straightforward integration under risk neutral pricing is used for deriving those formulas. For the application, bond of Bank Rakyat Indonesia (BRI) as one of the largest bank in Indonesia is analyzed. R computing show that value of the equity is IDR 453.724.549.000.000, the liability is IDR 2.657.394.000.000, and the probability if default is 5.645305E-47 %.

  8. A study of the impact properties of adhesively-bonded aluminum alloy based on impact velocity

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Teng; Cheon, Seong Sik; Cho, Jae Ung [Kongju National University, Cheonan (Korea, Republic of); Kinloch, Anthony J.; Blackman, Bamber R. K.; Sanchez, F. S. Rodriguez [Imperial College London, London (United Kingdom); Bang, Hye Jin; Lee, Sang Kyo; Cho, Chong Du [Inha University, Seoul (Korea, Republic of)

    2015-02-15

    In this study, an experiment and a simulation were carried out on colliding an adhesively-bonded tapered double cantilever beam (TDCB) at the impact velocities of 5 m/s, 7.5 m/s and 12.5 m/s. The analysis method of the corrected beam theory (CBT) was used to obtain the rate of energy release in the bonded area according to the crack progression, and a simulation was performed to determine the maximum strain energy during the impact analysis as a means to examine the mechanical properties of aluminium alloy. The experimental data were found to be higher than the simulation data. This is deemed to explicable by the fact that the adhesive strength was maintained even after the specimen separated in the experiment. Crack progression occurred, irrespective of the impact velocity, and high strain energy occurred at the end of the bonded region, thereby causing the strain energy to increase in the final stages. Also, the maximum load applied on the pin and the maximum strain energy in the bonded area were shown increase at higher impact velocities. The results of the experiment and simulation performed in this study are expected to serve as important data in developing a safety design for composite materials that can help prevent the progression of cracks caused by impact.

  9. Studies of Hydrogen Bonding Between N, N-Dimethylacetamide and Primary Alcohols

    Directory of Open Access Journals (Sweden)

    M. S. Manjunath

    2009-01-01

    Full Text Available Hydrogen bonding between N, N-dimethylacetamide (DMA and alcohols has been studied in carbon tetrachloride solution by an X-band Microwave bench at 936GHz. The dielectric relaxation time (τ of the binary system are obtained by both Higasi's method and Gopalakrishna method. The most likely association complex between alcohol and DMA is 1:1 stoichiometric complex through the hydroxyl group of the alcohol and the carbonyl group of amide. The results show that the interaction between alcohols and amides is 1:1 complex through the free hydroxyl group of the alcohol and the carbonyl group of amide and the alkyl chain-length of both the alcohols and amide plays an important role in the determination of the strength of hydrogen bond (O-H: C=O formed and suggests that the proton donating ability of alcohols is in the order: 1-propanol < 1-butanol < 1-pentanol and the accepting ability of DMA.

  10. Redshift or adduct stabilization -- a computational study of hydrogen bonding in adducts of protonated carboxylic acids

    DEFF Research Database (Denmark)

    Olesen, Solveig Gaarn; Hammerum, Steen

    2009-01-01

    It is generally expected that the hydrogen bond strength in a D-H-A adduct is predicted by the difference between the proton affinities of D and A, measured by the adduct stabilization, and demonstrated by the IR redshift of the D-H bond stretching vibrational frequency. These criteria do...... not always yield consistent predictions, as illustrated by the hydrogen bonds formed by the E and Z OH groups of protonated carboxylic acids. The delta-PA and the stabilization of a series of hydrogen bonded adducts indicate that the E OH group forms the stronger hydrogen bonds, whereas the bond length...... carboxylic acids are different. The OH bond length and IR redshift afford the better measure of hydrogen bond strength....

  11. Bonding to oxide ceramics—laboratory testing versus clinical outcome.

    Science.gov (United States)

    Kern, Matthias

    2015-01-01

    Despite a huge number of published laboratory bonding studies on dental oxide ceramics clinical long-term studies on resin bonded oxide ceramic restorations are rare. The purpose of this review is to present the best available clinical evidence for successful bonding of dental oxide ceramic restorations. Clinical trials with resin-bonded restorations that had no or only limited mechanical retention and were made from alumina or zirconia ceramic were identified using an electronic search in PubMed database. Overall 10 publications with clinical trials could be identified. Their clinical outcome was compared with that laboratory bond strength studies. Clinical data provide strong evidence that air-abrasion at a moderate pressure in combination with using phosphate monomer containing primers and/or luting resins provide long-term durable bonding to glass-infiltrated alumina and zirconia ceramic under the humid and stressful oral conditions. As simple and clinically reliable bonding methods to oxide ceramics exist, the rationale for development of alternative bonding methods might be reconsidered especially when these methods are more time consuming or require rather complicated and/or technique sensitive procedures. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  12. Science and technology of plasma activated direct wafer bonding

    Science.gov (United States)

    Roberds, Brian Edward

    This dissertation studied the kinetics of silicon direct wafer bonding with emphasis on low temperature bonding mechanisms. The project goals were to understand the topological requirements for initial bonding, develop a tensile test to measure the bond strength as a function of time and temperature and, using the kinetic information obtained, develop lower temperature methods of bonding. A reproducible surface metrology metric for bonding was best described by power spectral density derived from atomic force microscopy measurements. From the tensile strength kinetics study it was found that low annealing temperatures could be used to obtain strong bonds, but at the expense of longer annealing times. Three models were developed to describe the kinetics. A diffusion controlled model and a reaction rate controlled model were developed for the higher temperature regimes (T > 600sp°C), and an electric field assisted oxidation model was proposed for the low temperature range. An in situ oxygen plasma treatment was used to further enhance the field-controlled mechanism which resulted in dramatic increases in the low temperature bonding kinetics. Multiple internal transmission Fourier transform infrared spectroscopy (MIT-FTIR) was used to monitor species evolution at the bonded interface and a capacitance-voltage (CV) study was undertaken to investigate charge distribution and surface states resulting from plasma activation. A short, less than a minute, plasma exposure prior to contacting the wafers was found to obtain very strong bonds for hydrophobic silicon wafers at very low temperatures (100sp°C). This novel bonding method may enable new technologies involving heterogeneous material systems or bonding partially fabricated devices to become realities.

  13. Spectroscopic, DFT, and XRD Studies of Hydrogen Bonds in N-Unsubstituted 2-Aminobenzamides.

    Science.gov (United States)

    Mphahlele, Malose Jack; Maluleka, Marole Maria; Rhyman, Lydia; Ramasami, Ponnadurai; Mampa, Richard Mokome

    2017-01-04

    The structures of the mono- and the dihalogenated N -unsubstituted 2-aminobenzamides were characterized by means of the spectroscopic (¹H-NMR, UV-Vis, FT-IR, and FT-Raman) and X-ray crystallographic techniques complemented with a density functional theory (DFT) method. The hindered rotation of the C(O)-NH₂ single bond resulted in non-equivalence of the amide protons and therefore two distinct resonances of different chemical shift values in the ¹H-NMR spectra of these compounds were observed. 2-Amino-5-bromobenzamide ( ABB ) as a model confirmed the presence of strong intramolecular hydrogen bonds between oxygen and the amine hydrogen. However, intramolecular hydrogen bonding between the carbonyl oxygen and the amine protons was not observed in the solution phase due to a rapid exchange of these two protons with the solvent and fast rotation of the Ar-NH₂ single bond. XRD also revealed the ability of the amide unit of these compounds to function as a hydrogen bond donor and acceptor simultaneously to form strong intermolecular hydrogen bonding between oxygen of one molecule and the NH moiety of the amine or amide group of the other molecule and between the amine nitrogen and the amide hydrogen of different molecules. DFT calculations using the B3LYP/6-311++G(d,p) basis set revealed that the conformer ( A ) with oxygen and 2-amine on the same side predominates possibly due to the formation of a six-membered intramolecular ring, which is assisted by hydrogen bonding as observed in the single crystal XRD structure.

  14. Spectroscopic, DFT, and XRD Studies of Hydrogen Bonds in N-Unsubstituted 2-Aminobenzamides

    Directory of Open Access Journals (Sweden)

    Malose Jack Mphahlele

    2017-01-01

    Full Text Available The structures of the mono- and the dihalogenated N-unsubstituted 2-aminobenzamides were characterized by means of the spectroscopic (1H-NMR, UV-Vis, FT-IR, and FT-Raman and X-ray crystallographic techniques complemented with a density functional theory (DFT method. The hindered rotation of the C(O–NH2 single bond resulted in non-equivalence of the amide protons and therefore two distinct resonances of different chemical shift values in the 1H-NMR spectra of these compounds were observed. 2-Amino-5-bromobenzamide (ABB as a model confirmed the presence of strong intramolecular hydrogen bonds between oxygen and the amine hydrogen. However, intramolecular hydrogen bonding between the carbonyl oxygen and the amine protons was not observed in the solution phase due to a rapid exchange of these two protons with the solvent and fast rotation of the Ar–NH2 single bond. XRD also revealed the ability of the amide unit of these compounds to function as a hydrogen bond donor and acceptor simultaneously to form strong intermolecular hydrogen bonding between oxygen of one molecule and the NH moiety of the amine or amide group of the other molecule and between the amine nitrogen and the amide hydrogen of different molecules. DFT calculations using the B3LYP/6-311++G(d,p basis set revealed that the conformer (A with oxygen and 2-amine on the same side predominates possibly due to the formation of a six-membered intramolecular ring, which is assisted by hydrogen bonding as observed in the single crystal XRD structure.

  15. Study of a photo-induced lysozyme-riboflavin bond

    Energy Technology Data Exchange (ETDEWEB)

    Ferrer, I; Silva, E

    1985-01-01

    Irradiation of lysozyme in the presence of riboflavin results in the formation of a lysozyme-riboflavin adduct. Reduction and carboxymethylation of the four disulfide bonds as well as the chemical modification of the Tyr residues and the photochemical alteration of the His residue in lysozyme, do not affect the formation of the photo-induced lysozyme-riboflavin bond. When the lysozyme-riboflavin adduct was subjected to mild acid hydrolysis and ion exchange chromatography, the retention of a compound containing /sup 14/C-riboflavin was observed. Free /sup 14/C-riboflavin, on the contrary is not retained by the column. The photo-oxidation of free Trp in the presence of /sup 14/C-riboflavin, gave a compound which bound to the ion exchange resin like the above-mentioned derivative. The photo-oxidation of the Trp residues in lysozyme and in peptides obtained from lysozyme showed very high quantum yields, and these values were directly related to the incorporation of /sup 14/C-riboflavin in these samples.

  16. Study of a photo-induced lysozyme-riboflavin bond

    International Nuclear Information System (INIS)

    Ferrer, I.; Silva, E.

    1985-01-01

    Irradiation of lysozyme in the presence of riboflavin results in the formation of a lysozyme-riboflavin adduct. Reduction and carboxymethylation of the four disulfide bonds as well as the chemical modification of the Tyr residues and the photochemical alteration of the His residue in lysozyme, do not affect the formation of the photo-induced lysozyme-riboflavin bond. When the lysozyme-riboflavin adduct was subjected to mild acid hydrolysis and ion exchange chromatography, the retention of a compound containing 14 C-riboflavin was observed. Free 14 C-ribboflavin, on the contrary is not retained by the column. The photo-oxidation of free Trp in the presence of 14 C-riboflavin, gave a compound which bound to the ion exchange resin like the above-mentioned derivative. The photo-oxidation of the Trp residues in lysozyme and in peptides obtained from lysozyme showed very high quantum yields, and these values were directly related to the incorporation of 14 C-riboflavin in these samples. (orig.)

  17. Estimation of strength in different extra Watson-Crick hydrogen bonds in DNA double helices through quantum chemical studies.

    Science.gov (United States)

    Bandyopadhyay, D; Bhattacharyya, D

    2006-10-15

    It was shown earlier, from database analysis, model building studies, and molecular dynamics simulations that formation of cross-strand bifurcated or Extra Watson-Crick hydrogen (EWC) bonds between successive base pairs may lead to extra rigidity to DNA double helices of certain sequences. The strengths of these hydrogen bonds are debatable, however, as they do not have standard linear geometry criterion. We have therefore carried out detailed ab initio quantum chemical studies using RHF/6-31G(2d,2p) and B3LYP/6-31G(2p,2d) basis sets to determine strengths of several bent hydrogen bonds with different donor and acceptors. Interaction energy calculations, corrected for the basis set superposition errors, suggest that N-H...O type bent EWC hydrogen bonds are possible along same strands or across the strands between successive base pairs, leading to significant stability (ca. 4-9 kcal/mol). The N-H...N and C-H...O type interactions, however, are not so stabilizing. Hence, consideration of EWC N-H...O H-bonds can lead to a better understanding of DNA sequence directed structural features. Copyright (c) 2006 Wiley Periodicals, Inc.

  18. Shear bond strength of resin composite bonded with two adhesives: Influence of Er: YAG laser irradiation distance

    Science.gov (United States)

    Shirani, Farzaneh; Birang, Reza; Malekipour, Mohammad Reza; Hourmehr, Zahra; Kazemi, Shantia

    2014-01-01

    Background: Dental surfaces prepared with different Er:YAG laser distance may have different characteristics compared with those prepared with conventional instruments. The aim of this study was to investigate the effect of Er:YAG laser irradiation distance from enamel and dentin surfaces on the shear bond strength of composite with self-etch and etch and rinse bonding systems compared with conventional preparation method. Materials and Methods: Two hundred caries-free human third molars were randomly divided into twenty groups (n = 10). Ten groups were designated for enamel surface (E1-E10) and ten for dentin surface (D1-D10). Er: YAG laser (2940 nm) was used on the E1-E8 (240 mJ, 25 Hz) and D1-D8 (140 mJ, 30 Hz) groups at four different distances of 0.5 (standard), 2, 4 and 11 mm. Control groups (E9, E10, D9 and D10) were ground with medium grit diamond bur. The enamel and dentin specimens were divided into two subgroups that were bonded with either Single Bond or Clearfil SE Bond. Resin composite (Z100) was dispensed on prepared dentin and enamel. The shear bond strengths were tested using a universal testing machine. Data were analyzed by SPSS12 statistical software using three way analysis of variance, Tukey and independent t-test. P enamel and dentin substrates (P enamel surfaces (in both bonding agent subgroups) and on dentin surfaces (in the Single Bond subgroup). Conclusion: Laser irradiation decreases shear bond strength. Irradiation distance affects shear bond strength and increasing the distance would decrease the negative effects of laser irradiation. PMID:25540665

  19. Empirical studies on the cross-section of corporate bond and stock markets

    NARCIS (Netherlands)

    van Zundert, Jeroen

    2018-01-01

    This dissertation contains five empirical studies on the efficiency of corporate bond and stock markets. In Chapter 2, the pricing of interest rate risk in the stock market is analyzed. Over the long run, 1927 to 2015, the price of bearing interest rate risk is positive as expected, but there is

  20. The effect of pre-cure bracket movement on shear bond strength during placement of orthodontic brackets, an in vitro study.

    Science.gov (United States)

    Tam, Byron; Bollu, Prashanti; Chaudhry, Kishore; Subramani, Karthikeyan

    2017-10-01

    The purpose of this study was to determine the influence of linear and rotational pre-cure bracket displacement during the bonding procedure on shear bond strength (SBS) of orthodontic brackets. Stainless steel orthodontic premolar brackets were bonded to the buccal surfaces of 50 human pre-molars with a conventional two-step bonding protocol. Extracted human pre-molars were divided into 5 groups (n=10/group). In the Control Group, the brackets were bonded with no pre-cure bracket displacement or rotation. The Rotation Group was bonded with 45 degrees of pre-cure rotation. The Displacement Group was bonded with 2mm pre-cure linear displacement. The Rotation-Displacement Group was bonded with pre-cure movements of 45º counter-clockwise rotation and 2mm displacement. The Slippage Group was bonded with 2mm each of mesial and distal pre-cure linear displacement. Photo-activation was carried out on the lateral sides of the bracket. Shear debonding force was measured, 24 hours after initial bonding, with an Instron universal testing machine using a knife-edged chisel. Data was analyzed using one-way ANOVA test. Adhesive Remnant Index (ARI) was scored under 15x magnification. The ARI data was analyzed using the Chi-square test ( p -value bracket displacements do not appear to effect the shear bond strength of orthodontic brackets. Key words: Shear bond strength, orthodontic bracket, displacement, rotation, adhesive remnant index, pre-cure movement.

  1. [The bonding mechanisms of base metals for metal-ceramic crown microstructure analysis of bonding agent and gold bond between porcelain and base metals].

    Science.gov (United States)

    Wang, C C; Hsu, C S

    1996-06-01

    The use of base metal alloys for porcelain fused to a metal crown and bridges has increased recently because of lower price, high hardness, high tensile strength and high elastic modulus. The addition of beryllium to base metal alloys increased fluidity and improved casting fitness. Beryllium also controlled surface oxidation and bonding strength. The bonding agent and gold bonding agent also affected the bonding strength between porcelain and metal alloys. Four commercially available ceramic base alloys were studied (two alloys contained beryllium element, another two did not). The purpose of this investigation was to study the microstructure between porcelain matrix, bonding agent and alloy matrix interfaces. A scanning electron micro-probe analyzer and energy dispersive X-ray spectroscopy (EDXS) were used to study the distribution of elements (Ni, Cr, Mo, Cu, O, Si, Sn, Al) in four base alloys. The following results were obtained: 1. The thickness of the oxidized layer of Rexillium III alloy and Unitbond alloy (contained beryllium) was thinner than Unibond alloy and Wiron 88 alloy (no beryllium). 2. The thickness of the oxidized layer of alloys in air (10 minutes and 30 minutes) was thinner in Unitbond (2.45 microns and 3.80 microns) and thicker in Wiron 88 (4.39 microns and 5.96 microns). 3. The thickness of the oxidized layer occurring for a duration of ten minutes (in vaccum) showed that the Rexillium III alloy was the thinnest (1.93 microns), and Wiron 88 alloy was the thickest (2.30 microns). But in thirty minutes (vacuum), Unitbond alloy was the thinnest (3.37 microns), and Wiron 88 alloy was the thickest (5.51 microns). 4. The intensity of Cr elements was increased obviously near the interface between Unitbond alloy, Wiron 88 alloy (no beryllium) and oxidized layer, but the intensity of Ni and Mo elements was slightly increased. The intensity of Cr element was not increased markedly between Rexillium III alloy, Unitbond alloy (beryllium) and oxidized

  2. Tooth apatite as a bone substitute: an experimental study and clinical applications

    International Nuclear Information System (INIS)

    Eun-Seok Kim; Pill-Hoon Choung

    1999-01-01

    The purpose of this study is to evaluate the usefulness of calcined teeth powder as biological apatite. The animal experiment was performed in 36 rabbits aging 6 weeks and weighing 1.6 kg. In experimental group, tooth apatite powder was implanted to 10 mm bony defects in diameter made on the cranial bone of the rabbits. As control groups, synthetic porous hydroxyapatite and resorbable type calcium carbonate were implanted to the defects of same size. Each group was sacrificed in 1, 2, 4, 6, 8, 12 weeks after the surgery. Specimens were prepared for decalcified samples and observed by a light microscope. And we also performed quantitative analysis of new bone formation through image analysis using computer. In clinical applications, we used tooth apatite alone or mixed with decalcified freeze-dried bone for reconstruction of bony defects in 15 patients undergone enucleation of cyst or ameloblastoma. The obtained results were as follows; 1) The powder of the calcined teeth was called as 'tooth apatite' and it seemed to have biocompatibility in rabbits and human. 2) In group of tooth apatite, after 4 weeks of operation, new bone directly bonded to the particles was observed. And in 12 weeks of it, new bone occupied most of the bony defects. In 6 weeks, resorption of the tooth apatite particles was observed. Thus the tooth apatite was regarded as one of resorbable apatite. 3) The group of tooth apatite showed new bone formation similar to the group of porous hydroxyapatite, but they were inferior to the group of resorbable calcium carbonate. 4) In clinical application, tooth apatite had biocompatibility and new bone formation was observed without any complication except for 1 case. So we think it is a useful bone substitute with osteoconductivity

  3. A comparison of the use of bony anatomy and internal markers for offline verification and an evaluation of the potential benefit of online and offline verification protocols for prostate radiotherapy.

    Science.gov (United States)

    McNair, Helen A; Hansen, Vibeke N; Parker, Christopher C; Evans, Phil M; Norman, Andrew; Miles, Elizabeth; Harris, Emma J; Del-Acroix, Louise; Smith, Elizabeth; Keane, Richard; Khoo, Vincent S; Thompson, Alan C; Dearnaley, David P

    2008-05-01

    To evaluate the utility of intraprostatic markers in the treatment verification of prostate cancer radiotherapy. Specific aims were: to compare the effectiveness of offline correction protocols, either using gold markers or bony anatomy; to estimate the potential benefit of online correction protocol's using gold markers; to determine the presence and effect of intrafraction motion. Thirty patients with three gold markers inserted had pretreatment and posttreatment images acquired and were treated using an offline correction protocol and gold markers. Retrospectively, an offline protocol was applied using bony anatomy and an online protocol using gold markers. The systematic errors were reduced from 1.3, 1.9, and 2.5 mm to 1.1, 1.1, and 1.5 mm in the right-left (RL), superoinferior (SI), and anteroposterior (AP) directions, respectively, using the offline correction protocol and gold markers instead of bony anatomy. The subsequent decrease in margins was 1.7, 3.3, and 4 mm in the RL, SI, and AP directions, respectively. An offline correction protocol combined with an online correction protocol in the first four fractions reduced random errors further to 0.9, 1.1, and 1.0 mm in the RL, SI, and AP directions, respectively. A daily online protocol reduced all errors to markers is effective in reducing the systematic error. The value of online protocols is reduced by intrafraction motion.

  4. Evaluation of Shear Bond Strength of Orthodontic Brackets Bonded with Nano-filled Composites

    Directory of Open Access Journals (Sweden)

    Mohammad Sadegh Ahmad Akhoundi

    2013-01-01

    Full Text Available Objectives: The purpose of this study was to evaluate the shear bond strength (SBS of orthodontic brackets bonded with two types of nano-composites in comparison to a conventional orthodontic composite. Materials and Methods: Sixty extracted human first premolars were randomly divided into 3 groups each containing 20 teeth. In group I, a conventional orthodontic composite (Transbond XT was used to bond the brackets, while two nano-composites (Filtek TM Supreme XT and AELITE Aesthetic Enamel were used in groups II and III respectively. The teeth were stored in distilled water at 37°C for 24 hours, thermocycled in distilled water and debonded with a universal testing machine at a crosshead speed of 1 mm/min. The adhesive remnant index (ARI was also evaluated using a stereomicroscope. Results: AELITE Aesthetic Enamel nano-composite revealed a SBS value of 8.44±2.09 MPa, which was higher than Transbond XT (6.91± 2.13 and Filtek TM Supreme XT (6.04± 2.01. Statistical analysis revealed a significant difference between groups II and III (P 0.05. Evaluation of ARI showed that Transbond XT left fewer adhesive remains on teeth after debonding. Conclusion: Results of this study indicate that the aforementioned nano-composites can be successfully used for bonding orthodontic brackets.

  5. Safe and Liquid Mortgage Bonds

    DEFF Research Database (Denmark)

    Dick-Nielsen, Jens; Gyntelberg, Jacob; Lund, Jesper

    This paper shows that strict match pass-through funding of covered bonds provides safe and liquid mortgage bonds. Despite a 30% drop in house prices during the 2008 global crisis Danish mortgage bonds remained as liquid as most European government bonds. The Danish pass-through system effectively...... eliminates credit risk from the investor's perspective. Similar to other safe bonds, funding liquidity becomes the main driver of mortgage bond liquidity and this creates commonality in liquidity across markets and countries. These findings have implications for how to design a robust mortgage bond system...

  6. A carapace-like bony 'body tube' in an early triassic marine reptile and the onset of marine tetrapod predation.

    Science.gov (United States)

    Chen, Xiao-hong; Motani, Ryosuke; Cheng, Long; Jiang, Da-yong; Rieppel, Olivier

    2014-01-01

    Parahupehsuchus longus is a new species of marine reptile from the Lower Triassic of Yuan'an County, Hubei Province, China. It is unique among vertebrates for having a body wall that is completely surrounded by a bony tube, about 50 cm long and 6.5 cm deep, comprising overlapping ribs and gastralia. This tube and bony ossicles on the back are best interpreted as anti-predatory features, suggesting that there was predation pressure upon marine tetrapods in the Early Triassic. There is at least one sauropterygian that is sufficiently large to feed on Parahupehsuchus in the Nanzhang-Yuan'an fauna, together with six more species of potential prey marine reptiles with various degrees of body protection. Modern predators of marine tetrapods belong to the highest trophic levels in the marine ecosystem but such predators did not always exist through geologic time. The indication of marine-tetrapod feeding in the Nanzhang-Yuan'an fauna suggests that such a trophic level emerged for the first time in the Early Triassic. The recovery from the end-Permian extinction probably proceeded faster than traditionally thought for marine predators. Parahupehsuchus has superficially turtle-like features, namely expanded ribs without intercostal space, very short transverse processes, and a dorsal outgrowth from the neural spine. However, these features are structurally different from their turtle counterparts. Phylogeny suggests that they are convergent with the condition in turtles, which has a fundamentally different body plan that involves the folding of the body wall. Expanded ribs without intercostal space evolved at least twice and probably even more among reptiles.

  7. A carapace-like bony 'body tube' in an early triassic marine reptile and the onset of marine tetrapod predation.

    Directory of Open Access Journals (Sweden)

    Xiao-hong Chen

    Full Text Available Parahupehsuchus longus is a new species of marine reptile from the Lower Triassic of Yuan'an County, Hubei Province, China. It is unique among vertebrates for having a body wall that is completely surrounded by a bony tube, about 50 cm long and 6.5 cm deep, comprising overlapping ribs and gastralia. This tube and bony ossicles on the back are best interpreted as anti-predatory features, suggesting that there was predation pressure upon marine tetrapods in the Early Triassic. There is at least one sauropterygian that is sufficiently large to feed on Parahupehsuchus in the Nanzhang-Yuan'an fauna, together with six more species of potential prey marine reptiles with various degrees of body protection. Modern predators of marine tetrapods belong to the highest trophic levels in the marine ecosystem but such predators did not always exist through geologic time. The indication of marine-tetrapod feeding in the Nanzhang-Yuan'an fauna suggests that such a trophic level emerged for the first time in the Early Triassic. The recovery from the end-Permian extinction probably proceeded faster than traditionally thought for marine predators. Parahupehsuchus has superficially turtle-like features, namely expanded ribs without intercostal space, very short transverse processes, and a dorsal outgrowth from the neural spine. However, these features are structurally different from their turtle counterparts. Phylogeny suggests that they are convergent with the condition in turtles, which has a fundamentally different body plan that involves the folding of the body wall. Expanded ribs without intercostal space evolved at least twice and probably even more among reptiles.

  8. Hydrogen bonding analysis of hydroxyl groups in glucose aqueous solutions by a molecular dynamics simulation study

    International Nuclear Information System (INIS)

    Chen, Cong; Li, Wei Zhong; Song, Yong Chen; Weng, Lin Dong; Zhang, Ning

    2012-01-01

    Molecular dynamics simulations have been performed to investigate hydrogen bonding characteristics of hydroxyl groups in glucose aqueous solutions with different concentrations. The hydrogen bonding abilities and strength of different O and H atom types have been calculated and compared. The acceptor/donor efficiencies have been predicted and it has been found that: (1) O2-HO2 and O3-HO3 are more efficient intramolecular hydrogen bonding acceptors than donors; (2) O1-HO1, O4-HO4 and O6-HO6 are more efficient intramolecular hydrogen bonding donors than acceptors; (5) O1-HO1 and O6-HO6 are more efficient intermolecular hydrogen bonding acceptors than donors while hydroxyl groups O2-HO2 and O4-HO4 are more efficient intermolecular hydrogen bonding donors than acceptors. The hydrogen bonding abilities of hydroxyl groups revealed that: (1) the hydrogen bonding ability of OH2-H w is larger than that of hydroxyl groups in glucose; (2) among the hydroxyl groups in glucose, the hydrogen bonding ability of O6-HO6 is the largest and the hydrogen bonding ability of O4-HO4 is the smallest; (3) the intermolecular hydrogen bonding ability of O6-HO6 is the largest; (4) the order for intramolecular hydrogen bonding abilities (from large to small) is O2-HO2, O1-HO1, O3-HO3, O6-HO6 and O4-HO4

  9. Competition of hydrogen bonds and halogen bonds in complexes of hypohalous acids with nitrogenated bases.

    Science.gov (United States)

    Alkorta, Ibon; Blanco, Fernando; Solimannejad, Mohammad; Elguero, Jose

    2008-10-30

    A theoretical study of the complexes formed by hypohalous acids (HOX, X = F, Cl, Br, I, and At) with three nitrogenated bases (NH 3, N 2, and NCH) has been carried out by means of ab initio methods, up to MP2/aug-cc-pVTZ computational method. In general, two minima complexes are found, one with an OH...N hydrogen bond and the other one with a X...N halogen bond. While the first one is more stable for the smallest halogen derivatives, the two complexes present similar stabilities for the iodine case and the halogen-bonded structure is the most stable one for the hypoastatous acid complexes.

  10. Effects of Hybrid Coat on shear bond strength of five cements: an in vitro study.

    Science.gov (United States)

    Guo, Yue; Zhou, Hou-De; Feng, Yun-Zhi

    2017-12-01

    To evaluate the sealing performance of Hybrid Coat and its influence on the shear bond strength of five dentin surface cements. Six premolars were pretreated to expose the dentin surface prior to the application of Hybrid Coat. The microscopic characteristics of the dentinal surfaces were examined with scanning electron microscopy (SEM). Then, 40 premolars were sectioned longitudinally, and 80 semi-sections were divided into a control group (untreated) and a study group (treated by Hybrid Coat). Alloy restoration was bonded to the teeth specimen using five different cements. Shear bond strength was measured by the universal testing machine. The fracture patterns and the adhesive interface were observed using astereomicroscope. SEM revealed that the lumens of dentinal tubules were completely occluded by Hybrid Coat. The Hybrid Coat significantly improved the shear bond strength of resin-modified glass ionomer cement (RMGIC) and resin cement (RC) but weakened the performance of zinc phosphate cement (ZPC), zinc polycarboxylate cement (ZPCC) and glass ionomer cement (GIC). Hybrid Coat is an effective dentinal tubule sealant, and therefore its combined use with resin or resin-modified glass ionomer cements can be applied for the prostheses attachment purpose.

  11. Strength of Bond Covenants and Bond Assessment Framework

    Directory of Open Access Journals (Sweden)

    Noel Yahanpath

    2012-06-01

    Full Text Available We examine bond covenants of 29 New Zealand bond issues between 2001 and 2007.Results from the study indicate that protection provided for bondholders is weak and limited.On average, only 2-3 types of covenants are embedded with the issues and only 27% of thesecovenants provide full protection to the bondholders. However, bondholders are not compensated for taking the additional risk. We propose an alternative assessment framework that directly assesses the level of protection offered to bondholders. We calculate thecovenant quality score for the issues and classify them into four levels of protection: very high protection, moderate, low and very low. Recent legislative changes will go some way towards improving investor protection and confidence, but the effect is yet to be seen. This proposed scoring framework can be used by potential investors to complement the traditional credit ratings when making their investment decisions.

  12. Theoretical study of hydrogen bond interactions of fluvastatin with ι-carrageenan and λ-carrageenan.

    Science.gov (United States)

    Papadopoulos, Anastasios G; Sigalas, Michael P

    2011-07-01

    The binding of the reductase inhibitor drug fluvastatin, hydroxy-3-methylglutaryl coenzyme A, with the hydrophilic ι- or λ-carrageenan polymers, serving as potential controllers of the drug's release rate, have been studied at the density functional level of theory with the B3LYP exchange correlation functional. Three low energy conformers of fluvastatin have been calculated. The vibrational spectroscopic properties calculated for the most stable conformer were in satisfactory agreement with the experimental data. A series of hydrogen bonded complexes of the most stable conformer of fluvastatin anion with low molecular weight models of the polymers have been fully optimized. In almost all, intermolecular H-bonds are formed between the sulfate groups of ι- or λ-carrageenan and fluvastatin's hydroxyls, resulting in a red shift of the fluvastatin's O - H stretching vibrations. Cooperative intramolecular H-bonds within fluvastatin or ι-, λ-carrageenan are also present. The BSSE and ZPE corrected interaction energies were estimated in the range 281-318 kJ mol⁻¹ for ι-carrageenan - fluvastatin and 145-200 kJ mol⁻¹ for λ-carrageenan - fluvastatin complexes. The electron density (ρ (bcp)) and Laplacian (∇²ρ (bcp)) properties at critical points of the intermolecular hydrogen bonds, estimated by AIM (atoms in molecules) calculations, have a low and positive character (∇²ρ(bcp) > 0), consistent with the electrostatic character of the hydrogen bonds. The structural and energetic data observed, as well as the extent of the red shift of the fluvastatin's O - H stretching vibrations upon complex formation and the properties of electron density show a stronger binding of fluvastatin to ι- than to λ-carrageenan.

  13. Relationship Bonds and Customer Loyalty: A Study Across Different Service Contexts

    OpenAIRE

    Mafalda Lima; Teresa Fernandes

    2015-01-01

    The benefits of customer relationship strategies are well known and somewhat established nowadays. Customer loyalty emerges as the crucial glue in developing a relational approach. However, relational bonds, which relate to customer loyalty, have not yet been fully explored. Also, there is little research that takes into account the effect of service types on customer relationships and bonding. This paper develops a conceptual framework based on previous literature with a complete set of diff...

  14. [Study of parental bonding in childhood in children and adolescents with anorexia nervosa].

    Science.gov (United States)

    Albinhac, A M H; Jean, F A M; Bouvard, M P

    2018-04-16

    Anorexia nervosa constitutes a severe and complex eating disorder occurring principally in adolescence. It is one of the most deadly psychiatric disorders. Considering the multifactorial nature of anorexia nervosa, the important place of the family and the growing interest in the theory of attachment in eating disorders, parental bonding is questioned in anorexia nervosa. The main study goal is to analyze parental bonding in a population of children and adolescents with anorexia nervosa. The secondary objective is to study differences according to the age group. We realized an observational pilot study in Bordeaux over a period from June 2015 to April 2017. Twenty five young girls with anorexia nervosa, aged 10 to 17 years, hospitalized in the department of child and adolescent psychiatry and department of eating disorders have been included and divided into two groups: peripubertal for children under 14 and pubertal for children aged 14 to 17 years. We met them individually to complete a series of questionnaires including the Parental Bonding Instrument (for assessing attachment), the Mini International Neuropsychiatry Interview for Children and Adolescent (for detecting the presence of comorbidity) and a structured questionnaire for collecting general information on anorexia nervosa. Results revealed high parental care, high maternal and paternal overprotection with predominantly "optimal" parenting style followed by "affectionate constraint" style. Significant differences were observed in anorexia nervosa patients with maternal (P=0.011) and paternal (P=0.085) overprotection in pubes compared to peripubertal. In correlation analysis, there was a positive correlation between maternal protection and age of diagnosis and a negative correlation between parental care and duration of illness. Furthermore, the maternal overprotection tended to be correlated significantly and positively with the age of the diagnosis and the paternal overprotection with the body mass

  15. Evaluation of bond strength and load deflection rate of multi-stranded fixed retainer wires: An In-Vitro Study

    Directory of Open Access Journals (Sweden)

    Renu Sarah Samson

    2018-01-01

    Full Text Available Background: Fixed orthodontic retainers must be well retained on the tooth surfaces, allow physiologic movement of teeth and exert minimal forces on the teeth to be retained. Previous studies analyzed the bond strength and amount of deflection caused due to the debonding force but not the magnitude of force needed for unit deformation. Aims: This study aims to evaluate and compare the bond strength and load deflection rate (LDR of three different fixed retainer wires. Materials and Methods: The wires were divided into three Groups: A – three-stranded twisted ligature wire, B – Bond-A-Braid (Reliance Orthodontics, and C – three-stranded twisted lingual retainer wire (3M Unitek. Twenty models were prepared for each group with a passive 15 mm long lingual retainer wire bonded to two lower incisors. An occlusogingival force was applied to the wire until it debonded. For LDR, three-point bending test was done at 0.5 mm deflection. These forces were measured using a Universal Instron Testing Machine. Statistical Analysis: Mean bond strength/LDR and pairwise comparisons were analyzed with one-way ANOVA and Tukey's honest significant difference post hoc test, respectively. Results: Group C exhibited the highest mean bond strength and LDR of 101.17N and 1.84N, respectively. The intergroup comparisons were all statistically significant. Conclusion: Compared to the other two wire types, Group C might be better retained on the teeth due to its higher bond strength. With its relatively higher LDR value, it may resist deformation from occlusal forces, thereby reducing inadvertent tooth movement and yet remain flexible enough to allow physiologic tooth movements.

  16. Valuing Catastrophe Bonds Involving Credit Risks

    Directory of Open Access Journals (Sweden)

    Jian Liu

    2014-01-01

    Full Text Available Catastrophe bonds are the most important products in catastrophe risk securitization market. For the operating mechanism, CAT bonds may have a credit risk, so in this paper we consider the influence of the credit risk on CAT bonds pricing that is different from the other literature. We employ the Jarrow and Turnbull method to model the credit risks and get access to the general pricing formula using the Extreme Value Theory. Furthermore, we present an empirical pricing study of the Property Claim Services data, where the parameters in the loss function distribution are estimated by the MLE method and the default probabilities are deduced by the US financial market data. Then we get the catastrophe bonds value by the Monte Carlo method.

  17. Implante de biomateriais e a consolidação óssea em cadelas submetidas à ovariossalpingo-histerectomia Influence of biomaterials on the bony consolidation in spayed female dogs

    Directory of Open Access Journals (Sweden)

    A.I. Roque-Rodriguez

    2009-10-01

    Full Text Available Avaliou-se a hidroxiapatita com alandronato e hidroxiapatita com colágeno na aceleração da consolidação óssea do rádio de cadelas adultas submetidas à ovariossalpingo-histerectomia (OSH. Utilizaram-se 14 cadelas adultas, distribuídas aleatoriamente em dois grupos: grupo-controle e grupo OSH (submetidas à OSH. Quatro meses após a OSH, as cadelas dos dois grupos foram submetidas à cirurgia para produção de uma falha óssea de 4mm de diâmetro nos terços distal e proximal do rádio. No terço distal do membro direito, foi utilizada a hidroxiapatita com alandronato e, no membro esquerdo, a hidroxiapatita com colágeno; no terço proximal, não se utilizou nenhum biomaterial. Houve retardo na consolidação das falhas ósseas nas cadelas submetidas à OSH comparadas com as não submetidas. A hidroxiapatita com alandronato acelerou o processo de reparação e, em todos os animais dos dois grupos, a densidade óssea foi significativamente maior no terço distal onde foi implantada. Os dois biomateriais apresentaram biocompatibilidade, constatada pela ausência de reação inflamatória ou outra reação indesejável.The hydroxyapatite with alendronate and hydroxyapatite with collagen were evaluated in the acceleration of the bony consolidation of adult spayed bitch radius. For that, 14 adult bitches were distributed in two groups (control and spayed. Four months after ovariohysterectomy, the groups were submitted to the surgery for production of a 4mm diameter bony flaw in the distal and proximal third regions of the radius. In the distal region of the right thoracic limb, hydroxyapatite with alendronate was used. In the distal region of the left thoracic limb, hydroxyapatite with collagen was used. Any biomaterial was used in proximal part of the limb. There was a retard in bony flaws consolidation in the spayed bitches. Hydroxyapatite with alendronate showed better result, since the place it was implanted considerably increased the

  18. Crystallographic Studies Evidencing the High Energy Tolerance to Disrupting the Interface Disulfide Bond of Thioredoxin 1 from White Leg Shrimp Litopenaeus vannamei

    Directory of Open Access Journals (Sweden)

    Adam A. Campos-Acevedo

    2014-12-01

    Full Text Available Thioredoxin (Trx is a small 12-kDa redox protein that catalyzes the reduction of disulfide bonds in proteins from different biological systems. A recent study of the crystal structure of white leg shrimp thioredoxin 1 from Litopenaeus vannamei (LvTrx revealed a dimeric form of the protein mediated by a covalent link through a disulfide bond between Cys73 from each monomer. In the present study, X-ray-induced damage in the catalytic and the interface disulfide bond of LvTrx was studied at atomic resolution at different transmission energies of 8% and 27%, 12.8 keV at 100 K in the beamline I-24 at Diamond Light Source. We found that at an absorbed dose of 32 MGy, the X-ray induces the cleavage of the disulfide bond of each catalytic site; however, the interface disulfide bond was cleaved at an X-ray adsorbed dose of 85 MGy; despite being the most solvent-exposed disulfide bond in LvTrx (~50 Å2. This result clearly established that the interface disulfide bond is very stable and, therefore, less susceptible to being reduced by X-rays. In fact, these studies open the possibility of the existence in solution of a dimeric LvTrx.

  19. Crystallographic studies evidencing the high energy tolerance to disrupting the interface disulfide bond of thioredoxin 1 from white leg shrimp Litopenaeus vannamei.

    Science.gov (United States)

    Campos-Acevedo, Adam A; Rudiño-Piñera, Enrique

    2014-12-15

    Thioredoxin (Trx) is a small 12-kDa redox protein that catalyzes the reduction of disulfide bonds in proteins from different biological systems. A recent study of the crystal structure of white leg shrimp thioredoxin 1 from Litopenaeus vannamei (LvTrx) revealed a dimeric form of the protein mediated by a covalent link through a disulfide bond between Cys73 from each monomer. In the present study, X-ray-induced damage in the catalytic and the interface disulfide bond of LvTrx was studied at atomic resolution at different transmission energies of 8% and 27%, 12.8 keV at 100 K in the beamline I-24 at Diamond Light Source. We found that at an absorbed dose of 32 MGy, the X-ray induces the cleavage of the disulfide bond of each catalytic site; however, the interface disulfide bond was cleaved at an X-ray adsorbed dose of 85 MGy; despite being the most solvent-exposed disulfide bond in LvTrx (~50 Å2). This result clearly established that the interface disulfide bond is very stable and, therefore, less susceptible to being reduced by X-rays. In fact, these studies open the possibility of the existence in solution of a dimeric LvTrx.

  20. Shear bond strength of two bonding systems on dentin surfaces prepared with Er:YAG laser

    International Nuclear Information System (INIS)

    Dall'Magro, Eduardo

    2001-01-01

    The purpose of this study was to examine the shear bond strength of two bonding dentin systems, one 'one step' (Single Bond - 3M) and one 'self-etching' (Prompt-L-ESPE), when applied on dentin surfaces prepared with Er:YAG laser (2,94μm) that underwent ar not, acid etched. Forty one human molars just extracted were selected and after the cut with diamond disc and included in acrylic resin, resulting in 81 specimens (hemi crowns). After, the specimens were divided in one group treated with sand paper and another two groups treated with Er:YAG laser with 200 mJ and 250 mJ of energy and 2 Hz of frequency. Next, the prepared surfaces received three treatments with following application: 1) acid + Single Bond + Z 250 resin, 2) prompt-L-Pop + Z 250 resin, and 3) acid without, Single Bond + Z 250 resin. The Z 250 resin was applied and photopolymerized in increments on a Teflon matrix that belonged to an apparatus called 'Assembly Apparatus' machine producing cylinders of 3,5 mm of diameter and 5 mm of height. After these specimens were submitted to thermo cycling during 1 minute the 55 deg C and during 1 minute with 5 deg C with a total of 500 cycles for specimen, and the measures of shear bond strength were abstained using EMIC model DL 2000 rehearsed machine, with speed of 0,5 mm/min, measuring the final rupture tension (Mpa). The results showed an statistic superiority of 5% of probability level in dentin flattened with sandpaper and with laser using 200 mJ of energy with aspect to the ones flattened with laser using 250 mJ of energy. It was observed that using 'Single Bond' bonding dentin system the marks were statistically superior at 5% of probability with reference to the use of the Prompt-L-Pop adhesive system. So, it was concluded that Er:YAG Laser with 200 mJ of energy produced similar dentin cavity prepare than sandpaper and Single Bond seemed the best bonding agent system between restorative material and dentin. (author)

  1. Survival of flexible, braided, bonded stainless steel lingual retainers : a historic cohort study

    NARCIS (Netherlands)

    Foek, D. J. Lie Sam; Ozcan, M.; Verkerke, G. J.; Sandham, John; Dijkstra, P. U.

    The objectives of this study were to retrospectively evaluate the clinical survival rate of flexible, braided, rectangular bonded stainless steel lingual retainers, and to investigate the influence of gender, age of the patient, and operator experience on survival after orthodontic treatment at the

  2. Mutual influence between triel bond and cation-π interactions: an ab initio study

    Science.gov (United States)

    Esrafili, Mehdi D.; Mousavian, Parisasadat

    2017-12-01

    Using ab initio calculations, the cooperative and solvent effects on cation-π and B...N interactions are studied in some model ternary complexes, where these interactions coexist. The nature of the interactions and the mechanism of cooperativity are investigated by means of quantum theory of atoms in molecules (QTAIM), noncovalent interaction (NCI) index and natural bond orbital analysis. The results indicate that all cation-π and B...N binding distances in the ternary complexes are shorter than those of corresponding binary systems. The QTAIM analysis reveals that ternary complexes have higher electron density at their bond critical points relative to the corresponding binary complexes. In addition, according to the QTAIM analysis, the formation of cation-π interaction increases covalency of B...N bonds. The NCI analysis indicates that the cooperative effects in the ternary complexes make a shift in the location of the spike associated with each interaction, which can be regarded as an evidence for the reinforcement of both cation-π and B...N interactions in these systems. Solvent effects on the cooperativity of cation-π and B...N interactions are also investigated.

  3. Fusion bonding of silicon nitride surfaces

    DEFF Research Database (Denmark)

    Reck, Kasper; Østergaard, Christian; Thomsen, Erik Vilain

    2011-01-01

    While silicon nitride surfaces are widely used in many micro electrical mechanical system devices, e.g. for chemical passivation, electrical isolation or environmental protection, studies on fusion bonding of two silicon nitride surfaces (Si3N4–Si3N4 bonding) are very few and highly application...

  4. Diversification through Catastrophe Bonds: Lessons from the Subprime Financial Crisis

    OpenAIRE

    Peter Carayannopoulos; M Fabricio Perez

    2015-01-01

    Are catastrophe bonds (CAT bonds) zero-beta investments? Are they a valuable new source of diversification for investors? We study these questions by analysing the dynamic relations of CAT bond returns and the returns of the stock, corporate bond and government bond markets. Our multivariate GARCH model results provide evidence that CAT bonds are zero-beta assets only in non-crisis periods. We document that CAT bonds were not immune to the effects of the recent financial crisis. With the coll...

  5. Evidence for resonant bonding in phase-change materials studied by IR spectroscopy

    Directory of Open Access Journals (Sweden)

    K. Shportko

    2017-04-01

    Full Text Available Phase-change materials (PCM attract attention due to their unique properties. This remarkable portfolio also makes them promising for applications in novel data storage devices. In this study, we discuss differences in the optical properties of PCM and non-PCM in the IR caused by presence or absence of resonant bonding.

  6. Shariah Bond as Financial Instrument For Local Government

    Directory of Open Access Journals (Sweden)

    Anim Rahmayati

    2016-06-01

    Full Text Available This study aims to analyse the potential of sharia bonds in the region as an alternative to local financing. This research is a kind of literary descriptive qualitative research using SWOT analysis. The results of this study indicate that in the area of sharia bonds is an alternative worth considering regional funding compared to other funding. Support policy, very large financing needs for region infrastructure development, the market potential in the area of sharia bonds is an opportunity for local governments in Indonesia to immediately issue sharia bonds in the area.DOI:  10.15408/sjie.v5i1.3126

  7. Usulan Pengembangan Komunikasi Pemasaran Melalui Strategi Customer Bonding (Studi Kasus : Supermarket Hero di Jakarta

    Directory of Open Access Journals (Sweden)

    Ronald Sukwadi

    2012-03-01

    Full Text Available The consequence of competition is the decrease of the number of customers which causes Hero Supermarket closed down several of its outlets. This decrease is also caused by the existence of internal issue of marketing communication (promotion which lacked a strong concept. The ineffective selection of communication channel which in turn fails to conform the activity to the public. For that, the identification in marketing communication activity through Customer Bonding strategy is needed. Through marketing communication program assessment with Customer Bonding (Awareness Bonding, Relationship Bonding, and Advocacy Bonding, intensity of marketing communication problem can be identified, through survey assessment (management and costumer, analyzed with statistical testing like validity and reliability test, Spearman Correlation test and Cross tab test. The questionnaires will be given to 13 respondents from Hero Management by using quota sampling and 100 customers using stratified sampling.               Through marketing communication program assessment using Customer Bonding, marketing communication intensity and correlation analysis between marketing communication program and consumer loyalty are obtained. From this analysis, it is shown that there is noise in marketing communication that influences information sending to customer. Hero must maintain marketing communication program which focuses in marketing program that have competitive advantages. Beside that, evaluation has always to be done in order to improve customer loyalty. Keywords: communication, customer bonding, loyalty

  8. Orthodontic bracket bonding without previous adhesive priming: A meta-regression analysis.

    Science.gov (United States)

    Altmann, Aline Segatto Pires; Degrazia, Felipe Weidenbach; Celeste, Roger Keller; Leitune, Vicente Castelo Branco; Samuel, Susana Maria Werner; Collares, Fabrício Mezzomo

    2016-05-01

    To determine the consensus among studies that adhesive resin application improves the bond strength of orthodontic brackets and the association of methodological variables on the influence of bond strength outcome. In vitro studies were selected to answer whether adhesive resin application increases the immediate shear bond strength of metal orthodontic brackets bonded with a photo-cured orthodontic adhesive. Studies included were those comparing a group having adhesive resin to a group without adhesive resin with the primary outcome measurement shear bond strength in MPa. A systematic electronic search was performed in PubMed and Scopus databases. Nine studies were included in the analysis. Based on the pooled data and due to a high heterogeneity among studies (I(2)  =  93.3), a meta-regression analysis was conducted. The analysis demonstrated that five experimental conditions explained 86.1% of heterogeneity and four of them had significantly affected in vitro shear bond testing. The shear bond strength of metal brackets was not significantly affected when bonded with adhesive resin, when compared to those without adhesive resin. The adhesive resin application can be set aside during metal bracket bonding to enamel regardless of the type of orthodontic adhesive used.

  9. Thai students' mental model of chemical bonding

    Science.gov (United States)

    Sarawan, Supawadee; Yuenyong, Chokchai

    2018-01-01

    This Research was finding the viewing about concept of chemical bonding is fundamental to subsequent learning of various other topics related to this concept in chemistry. Any conceptions about atomic structures that students have will be shown their further learning. The purpose of this study is to interviews conceptions held by high school chemistry students about metallic bonding and to reveal mental model of atomic structures show according to the educational level. With this aim, the questionnaire prepared making use of the literature and administered for analysis about mental model of chemical bonding. It was determined from the analysis of answers of questionnaire the 10th grade, 11th grade and 12th grade students. Finally, each was shown prompts in the form of focus cards derived from curriculum material that showed ways in which the bonding in specific metallic substances had been depicted. Students' responses revealed that learners across all three levels prefer simple, realistic mental models for metallic bonding and reveal to chemical bonding.

  10. Effect of nanoscale surface roughness on the bonding energy of direct-bonded silicon wafers

    Science.gov (United States)

    Miki, N.; Spearing, S. M.

    2003-11-01

    Direct wafer bonding of silicon wafers is a promising technology for manufacturing three-dimensional complex microelectromechanical systems as well as silicon-on-insulator substrates. Previous work has reported that the bond quality declines with increasing surface roughness, however, this relationship has not been quantified. This article explicitly correlates the bond quality, which is quantified by the apparent bonding energy, and the surface morphology via the bearing ratio, which describes the area of surface lying above a given depth. The apparent bonding energy is considered to be proportional to the real area of contact. The effective area of contact is defined as the area sufficiently close to contribute to the attractive force between the two bonding wafers. Experiments were conducted with silicon wafers whose surfaces were roughened by a buffered oxide etch solution (BOE, HF:NH4F=1:7) and/or a potassium hydroxide solution. The surface roughness was measured by atomic force microscopy. The wafers were direct bonded to polished "monitor" wafers following a standard RCA cleaning and the resulting bonding energy was measured by the crack-opening method. The experimental results revealed a clear correlation between the bonding energy and the bearing ratio. A bearing depth of ˜1.4 nm was found to be appropriate for the characterization of direct-bonded silicon at room temperature, which is consistent with the thickness of the water layer at the interface responsible for the hydrogen bonds that link the mating wafers.

  11. Preparation of fluorescence quenched libraries containing interchain disulphide bonds for studies of protein disulphide isomerases

    DEFF Research Database (Denmark)

    Spetzler, J C; Westphal, V; Winther, Jakob R.

    1998-01-01

    Protein disulphide isomerase is an enzyme that catalyses disulphide redox reactions in proteins. In this paper, fluorogenic and interchain disulphide bond containing peptide libraries and suitable substrates, useful in the study of protein disulphide isomerase, are described. In order to establish...... the quenching chromophore (Tyr(NO2)) and Cys(pNpys) activated for reaction with a second thiol. The formation and cleavage of the interchain disulphide bonds in the library were monitored under a fluorescence microscope. Substrates to investigate the properties of protein disulphide isomerase in solution were...

  12. Study of the adsorption, electronic structure and bonding of C2H4 on the FeNi(1 1 1) surface

    International Nuclear Information System (INIS)

    Simonetti, S.; Brizuela, G.; Juan, A.

    2010-01-01

    The adsorption of C 2 H 4 on the FeNi(1 1 1) alloy surface has been studied by ASED-MO tight binding calculations. The C 2 H 4 molecule presents its most stable geometry with the C=C bond axis parallel to the surface along the [1, -1, 0] direction, bonded on top Fe atom and bonded along a Fe-Fe bridge site. As a consequence, the strength of the local Fe-Fe bond decreases between 37 and 62% of its original bulk value. This bond weakening is mainly due to the new C-Fe interactions however no Fe 3 C carbide formation is evidenced on surface. The Fe-Ni and Ni-Ni superficial bonds are only slightly modified.

  13. Unusually short chalcogen bonds involving organoselenium: insights into the Se-N bond cleavage mechanism of the antioxidant ebselen and analogues.

    Science.gov (United States)

    Thomas, Sajesh P; Satheeshkumar, K; Mugesh, Govindasamy; Guru Row, T N

    2015-04-27

    Structural studies on the polymorphs of the organoselenium antioxidant ebselen and its derivative show the potential of organic selenium to form unusually short Se⋅⋅⋅O chalcogen bonds that lead to conserved supramolecular recognition units. Se⋅⋅⋅O interactions observed in these polymorphs are the shortest such chalcogen bonds known for organoselenium compounds. The FTIR spectral evolution characteristics of this interaction from solution state to solid crystalline state further validates the robustness of this class of supramolecular recognition units. The strength and electronic nature of the Se⋅⋅⋅O chalcogen bonds were explored using high-resolution X-ray charge density analysis and atons-in-molecules (AIM) theoretical analysis. A charge density study unravels the strong electrostatic nature of Se⋅⋅⋅O chalcogen bonding and soft-metal-like behavior of organoselenium. An analysis of the charge density around Se-N and Se-C covalent bonds in conjunction with the Se⋅⋅⋅O chalcogen bonding modes in ebselen and its analogues provides insights into the mechanism of drug action in this class of organoselenium antioxidants. The potential role of the intermolecular Se⋅⋅⋅O chalcogen bonding in forming the intermediate supramolecular assembly that leads to the bond cleavage mechanism has been proposed in terms of electron density topological parameters in a series of molecular complexes of ebselen with reactive oxygen species (ROS). © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. X-ray-assisted positioning of patients treated by conformal arc radiotherapy for prostate cancer: Comparison of setup accuracy using implanted markers versus bony structures

    International Nuclear Information System (INIS)

    Soete, Guy; Cock, Mieke de; Verellen, Dirk; Michielsen, Dirk; Keuppens, Frans; Storme, Guy

    2007-01-01

    Purpose: The aim of this study was to compare setup accuracy of NovalisBody stereoscopic X-ray positioning using implanted markers in the prostate vs. bony structures in patients treated with dynamic conformal arc radiotherapy for prostate cancer. Methods and Materials: Random and systematic setup errors (RE and SE) of the isocenter with regard to the center of gravity of three fiducial markers were measured by means of orthogonal verification films in 120 treatment sessions in 12 patients. Positioning was performed using NovalisBody semiautomated marker fusion. The results were compared with a control group of 261 measurements in 15 patients who were positioned with NovalisBody automated bone fusion. In addition, interfraction and intrafraction prostate motion was registered in the patients with implanted markers. Results: Marker-based X-ray positioning resulted in a reduction of RE as well as SE in the anteroposterior, craniocaudal, and left-right directions compared with those in the control group. The interfraction prostate displacements with regard to the bony pelvis that could be avoided by marker positioning ranged between 1.6 and 2.8 mm for RE and between 1.3 and 4.3 mm for SE. Intrafraction random and systematic prostate movements ranged between 1.4 and 2.4 mm and between 0.8 and 1.3 mm, respectively. Conclusion: The problem of interfraction prostate motion can be solved by using implanted markers. In addition, the NovalisBody X-ray system performs more accurately with markers compared with bone fusion. Intrafraction organ motion has become the limiting factor for margin reduction around the clinical target volume

  15. BOND STRENGTH OF SELF-ETCH ADHESIVES WITH PRIMARY AND PERMANENT TEETH DENTIN – IN VITRO STUDY.

    Directory of Open Access Journals (Sweden)

    Natalia Gateva

    2012-03-01

    Full Text Available Objective: The aim of this study was to compare dentin bond strength of primary and permanent teeth with self-etching adhesive systems. Methods: On 40 intact specimens of primary and permanent teeth was created flat dentin surfaces. The patterns were divided in 4 groups. Two different self-etching adhesive systems were used – one two steps (AdheSE, VivaDent and one one step (AdheSE One, VivaDent. Resin composite build-ups were constructed by means of convetional copper ring after applying the adhesive. The specimens were stored in water for 72 h at room temperature. After that specimens were tested for macrotensile bond strength. Debonded surfaces were analyzed by SEM.Conclusions: The measured values of dentin bond strength after applying self-etching adhesives are statistically significant in group of permanent teeth in comparison with group of primary teeth, and for both adhesive generations. Two steps self-etching adhesive provide significant stronger dentin bond strength with both dentitions in comparison with one step self-etching adhesive.

  16. Australia's Bond Home Bias

    OpenAIRE

    Anil V. Mishra; Umaru B. Conteh

    2014-01-01

    This paper constructs the float adjusted measure of home bias and explores the determinants of bond home bias by employing the International Monetary Fund's high quality dataset (2001 to 2009) on cross-border bond investment. The paper finds that Australian investors' prefer investing in countries with higher economic development and more developed bond markets. Exchange rate volatility appears to be an impediment for cross-border bond investment. Investors prefer investing in countries with ...

  17. Hydrogen-bonding patterns involving a cyclic phosphate

    Indian Academy of Sciences (India)

    Administrator

    Phosphates, which always have electronegative oxygen atoms, bear no exception in their involvement in ... water makes the study of structural patterns due to H-bonding much too complicated. We ... H-bonding features found in all the above.

  18. Study of gluing and wire bonding for the Belle II Silicon Vertex Detector

    International Nuclear Information System (INIS)

    Kang, K.H.; Hara, K.; Higuchi, T.; Hyun, H.J.; Jeon, H.B.; Joo, C.W.; Kah, D.H.; Kim, H.J.; Mibe, T.; Onuki, Y.; Park, H.; Rao, K.K.; Sato, N.; Shimizu, N.; Tanida, K.; Tsuboyama, T.; Uozumi, S.

    2014-01-01

    This paper describes an investigation into gluing and wire bonding for assembling the Silicon Vertex Detector (SVD) for the Belle II experiment at KEK in Japan. Optimizing the gluing of the silicon microstrip sensors, the support frame, and the readout flex cables is important for achieving the required mechanical precision. The wire bonding between the sensors and the readout electronic chips also needs special care to maximize the physics capability of the SVD. The silicon sensors and signal fan out flex circuits (pitch adapters) are glued and connected using wire bonding. We determine that gluing quality is important for achieving good bonding efficiency. The standard deviation in the glue thickness for the best result is measured to be 3.11 μm. Optimal machine parameters for wire bonding are determined to be 70 mW power, 20 gf force, and 20 ms for the pitch adapter and 60 mW power, 20 gf force, and 20 ms for the silicon strip sensors; these parameters provide a pull force of (10.92±0.72) gf. With these settings, 75% of the pitch adapters and 25% of the strip sensors experience the neck-broken type of break

  19. Antibacterial Effect and Tensile Bond Strength of Self-etching Adhesive Resins with and without Methacryloyloxydodecylpyridinium Bromide: An in vitro Study.

    Science.gov (United States)

    Krishnamurthy, Madhuram; Kumar, V Naveen; Leburu, Ashok; Dhanavel, Chakravarthy; Selvendran, Kasiswamy E; Praveen, Nehrudhas

    2018-04-01

    Aim: The aim of the present study was to compare the antibacterial activity of a self-etching primer containing antibacterial monomer methacryloyloxydodecylpyridinium bromide (MDPB) (Clearfil protect bond) with a conventional self-etching primer without MDPB (Clearfil SE bond) against Streptococcus mutans and the effect of incorporation of MDPB on the tensile bond strength of the experimental self-etching primer (Clearfil protect bond). Materials and methods: The antibacterial activity of the self-etching primers was assessed using agar disk diffusion method and the diameters of the zones of inhibition were measured and ranked. For tensile bond strength testing, 20 noncarious human molars were selected and randomly divided into two groups comprising 10 teeth in each group. Group I specimens were treated with Clearfil SE bond (without MDPB). Group II specimens were treated with Clearfil protect bond (with MDPB). Composite material was placed incrementally and cured for 40 seconds in all the specimens. Tensile bond strength was estimated using the Instron Universal testing machine at a crosshead speed of 1 mm/min. Results: The addition of MDPB into a self-etching primer exerts potential antibacterial effect against S. mutans. The tensile bond strength of MDPB containing self-etching primer was slightly lower than that of the conventional self-etching Clearfil protect bond primer, but the difference was not statistically significant. Conclusion: Thus, a self-etching primer containing MDPB will be a boon to adhesive dentistry as it has bactericidal property with adequate tensile bond strength. Clinical significance: The concept of prevention of extension in adhesive dentistry would result in micro/nanoleakage due to the presence of residual bacteria in the cavity. Self-etching primers with MDPB would improve the longevity of such restorations by providing adequate antibacterial activity without compromising the bond strength. Keywords: Antibacterial property

  20. Paternal and maternal bonding styles in childhood are associated with the prevalence of chronic pain in a general adult population: the Hisayama Study.

    Science.gov (United States)

    Anno, Kozo; Shibata, Mao; Ninomiya, Toshiharu; Iwaki, Rie; Kawata, Hiroshi; Sawamoto, Ryoko; Kubo, Chiharu; Kiyohara, Yutaka; Sudo, Nobuyuki; Hosoi, Masako

    2015-07-31

    Previous research has suggested that extraordinary adverse experiences during childhood, such as abuse, are possible risk factors for the development of chronic pain. However, the relationship between the perceived parental bonding style during childhood and chronic pain has been much less studied. In this cross-sectional study, 760 community-dwelling Japanese adults were asked if they had pain that had been present for six months or more. They completed the Parental Bonding Instrument (PBI), a self-administrated questionnaire designed to assess perceived parental bonding, and the Patient Health Questionnaire-9 to assess current depressive symptoms. The PBI consists of care and overprotection subscales that are analyzed by assigning the parental bonding style to one of four quadrants: Optimal bonding (high care/low overprotection), neglectful parenting (low care/low overprotection), affectionate constraint (high care/high overprotection), and affectionless control (low care/high overprotection). Logistic regression analysis was done to estimate the contribution of the parental bonding style to the risk of chronic pain, controlling for demographic variables. Compared to the optimal bonding group, the odds ratios (ORs) for having chronic pain were significantly higher in the affectionless control group for paternal bonding (OR: 2.21, 95% CI: 1.50-3.27) and for maternal bonding (OR: 1.60, 95% CI: 1.09-2.36). After adjusting for depression, significance remained only for paternal bonding. The results demonstrate that the parental bonding style during childhood is associated with the prevalence of chronic pain in adults in the general population and that the association is more robust for paternal bonding than for maternal bonding.

  1. Proposal of new bonding technique 'Instantaneous Liquid Phase (ILP) Bonding'

    International Nuclear Information System (INIS)

    Zhang, Yue-Chang; Nakagawa, Hiroji; Matsuda, Fukuhisa.

    1987-01-01

    A new bonding technique named ''Instantaneous Liquid Phase (ILP) bonding'' suitable mainly for welding dissimilar materials was proposed by which instantaneous melting of one or two of the faying surfaces is utilized. The processes of ILP bonding are mainly consisted of three stages, namely the first stage forming thin liquid layer by rapid heating, the second stage joining both specimens by thin liquid layer, and the third stage cooling the specimens rapidly to avoid the formation of brittle layer. The welding temperatures of the specimens to be welded in ILP bonding are generally differentiated from each other. ILP bonding was applied for a variety of combinations of dissimilar materials of aluminum, aluminum alloys, titanium, titanium alloy, carbon steel, austenitic stainless steel, copper and tungsten, and for similar materials of stainless steel and nickel-base alloy. There were no microvoids in these welding joints, and the formation of brittle layer at the bonding interface was suppressed. The welded joints of Al + Ti, Cu + carbon steel and Cu + austenitic stainless steel showed the fracture in base metal having lower tensile strength. Further, the welded joints of Al + carbon steel, Al alloy + Ti, Al alloy + carbon steel or + austenitic stainless steel, Ti + carbon steel or + austenitic stainless steel showed better tensile properties in the comparison with diffusion welding. Furthermore, ILP bonding was available for welding same materials susceptible to hot cracking. Because of the existence of liquid layer, the welding pressure required was extremely low, and preparation of faying surface by simple tooling or polishing by no.80 emery paper was enough. The change in specimen length before and after welding was relatively little, only depending on the thickness of liquid layer. The welding time was very short, and thus high welding efficiency was obtained. (author)

  2. A theoretical study of molecular structure, optical properties and bond activation of energetic compound FOX-7 under intense electric fields

    Science.gov (United States)

    Tao, Zhiqiang; Wang, Xin; Wei, Yuan; Lv, Li; Wu, Deyin; Yang, Mingli

    2017-02-01

    Molecular structure, vibrational and electronic absorption spectra, chemical reactivity of energetic compound FOX-7, one of the most widely used explosives, were studied computationally in presence of an electrostatic field of 0.01-0.05 a.u. The Csbnd N bond, which usually triggers the decomposition of FOX-7, is shortened/elongated under a parallel/antiparallel field. The Csbnd N bond activation energy varies with the external electric field, decreasing remarkably with the field strength in regardless of the field direction. This is attributed to two aspects: the bond weakening by the field parallel to the Csbnd N bond and the stabilization effect on the transition-state structure by the field antiparallel to the bond. The variations in the structure and property of FOX-7 under the electric fields were further analyzed with its distributional polarizability, which is dependent on the charge transfer characteristics through the Csbnd N bond.

  3. Allergy to fish collagen: Thermostability of collagen and IgE reactivity of patients' sera with extracts of 11 species of bony and cartilaginous fish

    Directory of Open Access Journals (Sweden)

    Yukihiro Kobayashi

    2016-10-01

    Conclusions: The IgE reactivity of patients' sera to fish collagen in extracts was retained even when fish meat was treated by a high heating load. As for the fish collagen, the IgE reactivities to cartilaginous fish were lower than that to bony fish. Reducing IgE reactivity to fish meat using heat is difficult, and other modalities will be required to produce hypoallergenic fish meat.

  4. Endoscopic Modified Medial Maxillectomy for Fungal Ball of the Hypoplastic Maxillary Sinus With Bony Hypertrophy.

    Science.gov (United States)

    Nomura, Kazuhiro; Ikushima, Hiroyuki; Ozawa, Daiki; Shimizu, Yuichi; Arakawa, Kazuya; Suzuki, Jun; Hidaka, Hiroshi; Katori, Yukio; Ohyama, Kenji

    2018-05-01

    Sinus fungal ball is defined as noninvasive chronic rhino-sinusitis with a clump of mold in the paranasal sinuses, typically affecting the maxillary sinus. Fairly good outcomes of endoscopic surgery have been reported where the ball is removed through the antrostomy. However, the affected sinus tends to have a smaller cavity and thicker bony walls. As such, it is often challenging to maintain a window size that is sufficient to control possible recurrence. The endoscopic modified medial maxillectomy procedure was applied to a 61-year old and a 70-year old female patient with maxillary sinus fungal ball. Using this method, we created a much larger inferior meatal antrostomy without difficulty. The window provided us with an endoscopic view of the whole sinus and complete eradication of the lesion. Endoscopic modified medial maxillectomy is useful as a surgical procedure for maxillary sinus fungal ball and should be considered for better outcomes.

  5. A bonding study toward the quality assurance of Belle-II silicon vertex detector modules

    Energy Technology Data Exchange (ETDEWEB)

    Kang, K.H.; Jeon, H.B. [RSRI, Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Park, H., E-mail: sunshine@knu.ac.kr [RSRI, Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Uozumi, S. [RSRI, Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Adamczyk, K. [H. Niewodniczanski Institute of Nuclear Physics, Krakow 31-342 (Poland); Aihara, H. [Department of Physics, University of Tokyo, Tokyo 113-0033 (Japan); Angelini, C. [Dipartimento di Fisica, Universitá di Pisa, I-56127 Pisa (Italy); INFN Sezione di Pisa, I-56127 Pisa (Italy); Aziz, T.; Babu, V. [Tata Institute of Fundamental Research, Mumbai 400005 (India); Bacher, S. [H. Niewodniczanski Institute of Nuclear Physics, Krakow 31-342 (Poland); Bahinipati, S. [Indian Institute of Technology Bhubaneswar, Satya Nagar (India); Barberio, E.; Baroncelli, T. [School of Physics, University of Melbourne, Melbourne, Victoria 3010 (Australia); Basith, A.K. [Indian Institute of Technology Madras, Chennai 600036 (India); Batignani, G. [Dipartimento di Fisica, Universitá di Pisa, I-56127 Pisa (Italy); INFN Sezione di Pisa, I-56127 Pisa (Italy); Bauer, A. [Institute of High Energy Physics, Austrian Academy of Sciences, 1050 Vienna (Austria); Behera, P.K. [Indian Institute of Technology Madras, Chennai 600036 (India); Bergauer, T. [Institute of High Energy Physics, Austrian Academy of Sciences, 1050 Vienna (Austria); Bettarini, S. [Dipartimento di Fisica, Universitá di Pisa, I-56127 Pisa (Italy); INFN Sezione di Pisa, I-56127 Pisa (Italy); Bhuyan, B. [Indian Institute of Technology Guwahati, Assam 781039 (India); and others

    2016-09-21

    A silicon vertex detector (SVD) for the Belle-II experiment comprises four layers of double-sided silicon strip detectors (DSSDs), assembled in a ladder-like structure. Each ladder module of the outermost SVD layer has four rectangular and one trapezoidal DSSDs supported by two carbon-fiber ribs. In order to achieve a good signal-to-noise ratio and minimize material budget, a novel chip-on-sensor “Origami” method has been employed for the three rectangular sensors that are sandwiched between the backward rectangular and forward (slanted) trapezoidal sensors. This paper describes the bonding procedures developed for making electrical connections between sensors and signal fan-out flex circuits (i.e., pitch adapters), and between pitch adapters and readout chips as well as the results in terms of the achieved bonding quality and pull force. - Highlights: • Gluing and wire binding for Belle-II SVD are studied. • Gluing robot and Origami module are used. • QA are satisfied in terms of the achieved bonding throughput and the pull force. • Result will be applied for L6 ladder assembly.

  6. A bonding study toward the quality assurance of Belle-II silicon vertex detector modules

    International Nuclear Information System (INIS)

    Kang, K.H.; Jeon, H.B.; Park, H.; Uozumi, S.; Adamczyk, K.; Aihara, H.; Angelini, C.; Aziz, T.; Babu, V.; Bacher, S.; Bahinipati, S.; Barberio, E.; Baroncelli, T.; Basith, A.K.; Batignani, G.; Bauer, A.; Behera, P.K.; Bergauer, T.; Bettarini, S.; Bhuyan, B.

    2016-01-01

    A silicon vertex detector (SVD) for the Belle-II experiment comprises four layers of double-sided silicon strip detectors (DSSDs), assembled in a ladder-like structure. Each ladder module of the outermost SVD layer has four rectangular and one trapezoidal DSSDs supported by two carbon-fiber ribs. In order to achieve a good signal-to-noise ratio and minimize material budget, a novel chip-on-sensor “Origami” method has been employed for the three rectangular sensors that are sandwiched between the backward rectangular and forward (slanted) trapezoidal sensors. This paper describes the bonding procedures developed for making electrical connections between sensors and signal fan-out flex circuits (i.e., pitch adapters), and between pitch adapters and readout chips as well as the results in terms of the achieved bonding quality and pull force. - Highlights: • Gluing and wire binding for Belle-II SVD are studied. • Gluing robot and Origami module are used. • QA are satisfied in terms of the achieved bonding throughput and the pull force. • Result will be applied for L6 ladder assembly.

  7. Bonding and structure of copper nitrenes.

    Science.gov (United States)

    Cundari, Thomas R; Dinescu, Adriana; Kazi, Abul B

    2008-11-03

    Copper nitrenes are of interest as intermediates in the catalytic aziridination of olefins and the amination of C-H bonds. However, despite advances in the isolation and study of late-transition-metal multiply bonded complexes, a bona fide structurally characterized example of a terminal copper nitrene has, to our knowledge, not been reported. In anticipation of such a report, terminal copper nitrenes are studied from a computational perspective. The nitrene complexes studied here are of the form (beta-diketiminate)Cu(NPh). Density functional theory (DFT), complete active space self-consistent-field (CASSCF) electronic structure techniques, and hybrid quantum mechanical/molecular mechanical (QM/MM) methods are employed to study such species. While DFT methods indicate that a triplet (S = 1) is the ground state, CASSCF calculations indicate that a singlet (S = 0) is the ground state, with only a small energy gap between the singlet and triplet. Moreover, the ground-state (open-shell) singlet copper nitrene is found to be highly multiconfigurational (i.e., biradical) and to possess a bent geometry about the nitrene nitrogen, contrasting with the linear nitrene geometry of the triplet copper nitrenes. CASSCF calculations also reveal the existence of a closed-shell singlet state with some degree of multiple bonding character for the copper-nitrene bond.

  8. Integration of European Bond Markets

    DEFF Research Database (Denmark)

    Christiansen, Charlotte

    2014-01-01

    I investigate the time variation in the integration of EU government bond markets. The integration is measured by the explanatory power of European factor portfolios for the individual bond markets for each year. The integration of the government bond markets is stronger for EMU than non-EMU memb......I investigate the time variation in the integration of EU government bond markets. The integration is measured by the explanatory power of European factor portfolios for the individual bond markets for each year. The integration of the government bond markets is stronger for EMU than non...

  9. Bond financing for renewable energy in Asia

    International Nuclear Information System (INIS)

    Ng, Thiam Hee; Tao, Jacqueline Yujia

    2016-01-01

    Addressing the financing gap for renewable energy (RE) projects in Asia is critical to ensure that the rapidly increasing energy needs could be met sustainably. This paper explores the cause of the financing gap in Asia and proposes the use of bond financing to address the financing gap. Specifically, three fixed income instruments, namely local currency denominated (LCY) corporate bonds, asset backed project bonds and financial green bonds, will be assessed. Whilst the potential for these three instruments to mobilize large flows of private sector financing is great, key supportive policies aimed at reducing the capital market bias for conventional power generation technologies and supportive RE policies are required. Another key aspect would be the necessary deepening of local and regional fixed income markets before such capital market instruments are able to play a big role. - Highlights: •This study looks at the current financing gap and RE financing landscape in developing Asia. •LCY corporate bonds, asset backed projects bonds and financial green bonds could help to address the financing gap for RE in the region. •Policy recommendations for building the fixed income market for RE projects are provided.

  10. Protection of MOS capacitors during anodic bonding

    Science.gov (United States)

    Schjølberg-Henriksen, K.; Plaza, J. A.; Rafí, J. M.; Esteve, J.; Campabadal, F.; Santander, J.; Jensen, G. U.; Hanneborg, A.

    2002-07-01

    We have investigated the electrical damage by anodic bonding on CMOS-quality gate oxide and methods to prevent this damage. n-type and p-type MOS capacitors were characterized by quasi-static and high-frequency CV-curves before and after anodic bonding. Capacitors that were bonded to a Pyrex wafer with 10 μm deep cavities enclosing the capacitors exhibited increased leakage current and interface trap density after bonding. Two different methods were successful in protecting the capacitors from such damage. Our first approach was to increase the cavity depth from 10 μm to 50 μm, thus reducing the electric field across the gate oxide during bonding from approximately 2 × 105 V cm-1 to 4 × 104 V cm-1. The second protection method was to coat the inside of a 10 μm deep Pyrex glass cavity with aluminium, forming a Faraday cage that removed the electric field across the cavity during anodic bonding. Both methods resulted in capacitors with decreased interface trap density and unchanged leakage current after bonding. No change in effective oxide charge or mobile ion contamination was observed on any of the capacitors in the study.

  11. Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies

    Directory of Open Access Journals (Sweden)

    Laura AlveBastos

    2015-02-01

    Full Text Available Objectives The aim of this study was to evaluate the effect of pre-etching on the bond strength of silorane-based composite specific adhesive system to dentin. Materials and Methods Thirty human molars were randomly divided into 5 groups according to the different bonding strategies. For teeth restored with silorane-based composite (Filtek Silorane, 3M ESPE, the specific self-etching adhesive system (Adhesive System P90, 3M ESPE was used with and without pre-etching (Pre-etching/Silorane and Silorane groups. Teeth restored with methacrylate based-composite (Filtek Z250, 3M ESPE were hybridized with the two-step self-etching system (Clearfil SE Bond, Kuraray, with and without pre-etching (Pre-etching/Methacrylate and Methacrylate groups, or three-step adhesive system (Adper Scotchbond Multi-Purpose, 3M ESPE (Three-step/Methacrylate group (n = 6. The restored teeth were sectioned into stick-shaped test specimens (1.0 × 1.0 mm, and coupled to a universal test machine (0.5 mm/min to perform microtensile testing. Results Pre-etching/Methacrylate group presented the highest bond strength values, with significant difference from Silorane and Three-step/Methacrylate groups (p < 0.05. However, it was not significantly different from Preetching/Silorane and Methacrylate groups. Conclusions Pre-etching increased bond strength of silorane-based composite specific adhesive system to dentin.

  12. Effect of Silica fume and superplasticizer on steel-concrete bond

    International Nuclear Information System (INIS)

    Esfahani, M. R.

    2001-01-01

    This paper presents a study on the influence of silica fume and super plasticizer on bond strength. The study included tests of fifty short length pull-out specimens in five series. The effect of silica fume and super plasticizer on bond strength was evaluated separately by tests of specimens made of concretes with similar strengths but different admixtures. Test results showed that the addition of silica fume in the concrete mixture had not a negative effect on bond strength. Also, there was not a considerable decrease in bond strength of specimens made of concrete with super plasticizer. Comparing the measured bond strengths normalized with respect to the square root of the concrete compressive strength, it was seen that the normalized bond strength increased with the concrete strength. this result agrees with the model previously proposed by the author for local bond strength. For the specimens made of high strength concrete including silica fume and super plasticizer, the normalized bond strength did not increase with the concrete strength

  13. Fusion-bonded fluidic interconnects

    International Nuclear Information System (INIS)

    Fazal, I; Elwenspoek, M C

    2008-01-01

    A new approach to realize fluidic interconnects based on the fusion bonding of glass tubes with silicon is presented. Fusion bond strength analyses have been carried out. Experiments with plain silicon wafers and coated with silicon oxide and silicon nitride are performed. The obtained results are discussed in terms of the homogeneity and strength of fusion bond. High pressure testing shows that the bond strength is large enough for most applications of fluidic interconnects. The bond strength for 525 µm thick silicon, with glass tubes having an outer diameter of 6 mm and with a wall thickness of 2 mm, is more than 60 bars after annealing at a temperature of 800 °C

  14. Hydrogen bonding interactions between ethylene glycol and water: density, excess molar volume, and spectral study

    Institute of Scientific and Technical Information of China (English)

    ZHANG JianBin; ZHANG PengYan; MA Kai; HAN Fang; CHEN GuoHua; WEI XiongHui

    2008-01-01

    Studies of the density and the excess molar volume of ethylene glycol (EG)-water mixtures were carried out to illustrate the hydrogen bonding interactions of EG with water at different temperatures, The re-sults suggest that a likely complex of 3 ethylene glycol molecules bonding with 4 water molecules in an ethylene glycol-water mixture (EGW) is formed at the maximal excess molar volume, which displays stronger absorption capabilities for SO2 when the concentration of SO2 reaches 400×106 (volume ratio) in the gas phase. Meanwhile, FTIR and UV spectra of EGWs were recorded at various EG concentra-tions to display the hydrogen bonding interactions of EG with water. The FTIR spectra show that the stretching vibrational band of hydroxyl in the EGWs shifts to a lower frequency and the bending vibra-tional band of water shifts to a higher frequency with increasing the EG concentration, respectively. Furthermore, the UV spectra show that the electron transferring band of the hydroxyl oxygen in EG shows red shift with increasing the EG concentration. The frequency shifts in FTIR spectra and the shifts of absorption bands in UV absorption spectra of EGWs are interpreted as the strong hydrogen bonding interactions of the hydrogen atoms in water with the hydroxyl oxygen atoms of EG.

  15. Hydrogen bonding interactions between ethylene glycol and water:density,excess molar volume,and spectral study

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Studies of the density and the excess molar volume of ethylene glycol (EG)-water mixtures were carried out to illustrate the hydrogen bonding interactions of EG with water at different temperatures. The re-sults suggest that a likely complex of 3 ethylene glycol molecules bonding with 4 water molecules in an ethylene glycol-water mixture (EGW) is formed at the maximal excess molar volume,which displays stronger absorption capabilities for SO2 when the concentration of SO2 reaches 400×10?6 (volume ratio) in the gas phase. Meanwhile,FTIR and UV spectra of EGWs were recorded at various EG concentra-tions to display the hydrogen bonding interactions of EG with water. The FTIR spectra show that the stretching vibrational band of hydroxyl in the EGWs shifts to a lower frequency and the bending vibra-tional band of water shifts to a higher frequency with increasing the EG concentration,respectively. Furthermore,the UV spectra show that the electron transferring band of the hydroxyl oxygen in EG shows red shift with increasing the EG concentration. The frequency shifts in FTIR spectra and the shifts of absorption bands in UV absorption spectra of EGWs are interpreted as the strong hydrogen bonding interactions of the hydrogen atoms in water with the hydroxyl oxygen atoms of EG.

  16. Analysis on Adhesively-Bonded Joints of FRP-steel Composite Bridge under Combined Loading : Arcan Test Study and Numerical Modeling

    NARCIS (Netherlands)

    Jiang, X.; Qiang, X.; Kolstein, M.H.; Bijlaard, F.S.K.

    2016-01-01

    The research presented in this paper is an experimental study and numerical analysis on mechanical behavior of the adhesively-bonded joint between FRP sandwich bridge deck and steel girder. Generally, there are three typical stress states in the adhesively-bonded joint: shear stress, tensile stress,

  17. Cement bond evaluation method in horizontal wells using segmented bond tool

    Science.gov (United States)

    Song, Ruolong; He, Li

    2018-06-01

    Most of the existing cement evaluation technologies suffer from tool eccentralization due to gravity in highly deviated wells and horizontal wells. This paper proposes a correction method to lessen the effects of tool eccentralization on evaluation results of cement bond using segmented bond tool, which has an omnidirectional sonic transmitter and eight segmented receivers evenly arranged around the tool 2 ft from the transmitter. Using 3-D finite difference parallel numerical simulation method, we investigate the logging responses of centred and eccentred segmented bond tool in a variety of bond conditions. From the numerical results, we find that the tool eccentricity and channel azimuth can be estimated from measured sector amplitude. The average of the sector amplitude when the tool is eccentred can be corrected to the one when the tool is centred. Then the corrected amplitude will be used to calculate the channel size. The proposed method is applied to both synthetic and field data. For synthetic data, it turns out that this method can estimate the tool eccentricity with small error and the bond map is improved after correction. For field data, the tool eccentricity has a good agreement with the measured well deviation angle. Though this method still suffers from the low accuracy of calculating channel azimuth, the credibility of corrected bond map is improved especially in horizontal wells. It gives us a choice to evaluate the bond condition for horizontal wells using existing logging tool. The numerical results in this paper can provide aids for understanding measurements of segmented tool in both vertical and horizontal wells.

  18. BCB Bonding Technology of Back-Side Illuminated COMS Device

    Science.gov (United States)

    Wu, Y.; Jiang, G. Q.; Jia, S. X.; Shi, Y. M.

    2018-03-01

    Back-side illuminated CMOS(BSI) sensor is a key device in spaceborne hyperspectral imaging technology. Compared with traditional devices, the path of incident light is simplified and the spectral response is planarized by BSI sensors, which meets the requirements of quantitative hyperspectral imaging applications. Wafer bonding is the basic technology and key process of the fabrication of BSI sensors. 6 inch bonding of CMOS wafer and glass wafer was fabricated based on the low bonding temperature and high stability of BCB. The influence of different thickness of BCB on bonding strength was studied. Wafer bonding with high strength, high stability and no bubbles was fabricated by changing bonding conditions.

  19. Financial and operational ratios for bond-insured hospitals.

    Science.gov (United States)

    McCue, Michael J; McCluer, R Forrest

    2008-01-01

    Few, if any, researchers have analyzed the performance indicators of companies that offer bond insurance to hospitals and healthcare systems. The authors of this study analyzed the key financial and operational indicators of independent hospitals and hospitals within large multihospital systems that are insured by the 5 major bond insurance companies. The authors examined 87 insured bond issues; the results of this study show that some insurers cover healthcare facilities that have strong operational traits and others focus on financial factors.

  20. Microstructure and properties of hot roll bonding layer of dissimilar metals. 2. Bonding interface microstructure of Zr/stainless steel by hot roll bonding and its controlling

    International Nuclear Information System (INIS)

    Yasuyama, Masanori; Ogawa, Kazuhiro; Taka, Takao; Nakasuji, Kazuyuki; Nakao, Yoshikuni; Nishimoto, Kazutoshi.

    1996-01-01

    The hot roll bonding of zirconium and stainless steel inserted with tantalium was investigated using the newly developed rolling mill. The effect of hot rolling temperatures of zirconium/stainless steel joints on bonding interface structure was evaluated. Intermetallic compound layer containing cracks was observed at the bonding interface between stainless steel and tantalium when the rolling temperature was above 1373K. The hardness of the bonding layer of zirconium and tantalium bonded above 1273K was higher than tantalium or zirconium base metal in spite of absence of intermetallic compound. The growth of reaction layer at the stainless steel and tantalium interface and at the tantalium and zirconium interface was conforming a parabolic low when that was isothermally heated after hot roll bonding, and the growth rate was almost same as that of static diffusion bonding without using hot roll bonding process. It is estimated that the strain caused by hot roll bonding gives no effect on the growth of reaction layer. It was confirmed that the dissimilar joint of zirconium and stainless steel with insert of tantalium having the sound bonding interface were obtained at the suitable bonding temperature of 1173K by the usage of the newly developed hot roll bonding process. (author)

  1. Prediction of fracture toughness and durability of adhesively bonded composite joints with undesirable bonding conditions

    Science.gov (United States)

    Musaramthota, Vishal

    Advanced composite materials have enabled the conventional aircraft structures to reduce weight, improve fuel efficiency and offer superior mechanical properties. In the past, materials such as aluminum, steel or titanium have been used to manufacture aircraft structures for support of heavy loads. Within the last decade or so, demand for advanced composite materials have been emerging that offer significant advantages over the traditional metallic materials. Of particular interest in the recent years, there has been an upsurge in scientific significance in the usage of adhesively bonded composite joints (ABCJ's). ABCJ's negate the introduction of stress risers that are associated with riveting or other classical techniques. In today's aircraft transportation market, there is a push to increase structural efficiency by promoting adhesive bonding to primary joining of aircraft structures. This research is focused on the issues associated with the durability and related failures in bonded composite joints that continue to be a critical hindrance to the universal acceptance of ABCJ's. Of particular interest are the short term strength, contamination and long term durability of ABCJ's. One of the factors that influence bond performance is contamination and in this study the influence of contamination on composite-adhesive bond quality was investigated through the development of a repeatable and scalable surface contamination procedure. Results showed an increase in the contaminant coverage area decreases the overall bond strength significantly. A direct correlation between the contaminant coverage area and the fracture toughness of the bonded joint was established. Another factor that influences bond performance during an aircraft's service life is its long term strength upon exposure to harsh environmental conditions or when subjected to severe mechanical loading. A test procedure was successfully developed in order to evaluate durability of ABCJ's comprising severe

  2. Study on the bonding state for carbon-boron nitrogen with different ball milling time

    International Nuclear Information System (INIS)

    Xiong, Y.H.; Xiong, C.S.; Wei, S.Q.; Yang, H.W.; Mai, Y.T.; Xu, W.; Yang, S.; Dai, G.H.; Song, S.J.; Xiong, J.; Ren, Z.M.; Zhang, J.; Pi, H.L.; Xia, Z.C.; Yuan, S.L.

    2006-01-01

    The varied bonding state and microstructure characterization were discussed for carbon-boron nitrogen (CBN) with abundant phase structure and nanostructure, which were synthesized directly by mechanical alloying technique at room temperature. According to the results of SEM and X-ray photoelectron spectroscopy (XPS) of CBN with different ball milling time, it is substantiated that the bonding state and microstructure for CBN were closely related to the ball milling time. With the increase of the ball milling time, some new chemical bonding states of CBN were observed, which implies that some new bonding state and microstructures have been formed. The results of XPS are accordance with that of X-ray diffraction of CBN

  3. A 19F NMR study of C-I....pi- halogen bonding

    DEFF Research Database (Denmark)

    Hauchecorne, Dieter; vand er Veken, Benjamin J.; Herrebout, Wouter A.

    2011-01-01

    The formation of halogen bonded complexes between toluene-d8 and the perfluoroiodopropanes 1-C3F7I and 2-C3F7I has been investigated using 19F NMR spectroscopy. For both Lewis acids, evidence was found for the formation of a C–I⋯π halogen bonded complex. The complex formed is a 1:1 type. Using sp...... results are supported by ab initio calculations at the B3LYP-PCM/6-311++G(d,p) + LanL2DZ∗ level....

  4. Parental bonding and suicidality in pregnant teenagers: a population-based study in southern Brazil.

    Science.gov (United States)

    Coelho, Fábio Monteiro da Cunha; Pinheiro, Ricardo Tavares; Silva, Ricardo Azevedo; de Ávila Quevedo, Luciana; de Mattos Souza, Luciano Dias; de Matos, Mariana Bonati; Castelli, Rochele Dias; Pinheiro, Karen Amaral Tavares

    2014-08-01

    To assess the associations of the perceived quality of parental bonding with suicidality in a sample of pregnant adolescents. A cross-sectional study with a sample size of 828 pregnant teenagers receiving prenatal medical assistance in the national public health system in the urban area of Pelotas, southern Brazil. Suicidality and psychiatric disorders were assessed using the Mini International Neuropsychiatric Interview (MINI), and the Parental Bonding Instrument (PBI) was employed to measure the perceived quality of parental bonding. A self-report questionnaire was used to collect sociodemographic, obstetric and other psychosocial data. Forty-three (4.94 %) teenagers from a consecutive sample of 871 refused to participate, resulting in 828 participants. Prevalence of suicidality was 13.3 %, lifetime suicide attempts were 7.4 % with 1.3 % reporting attempting suicide within the last month. Significant associations of suicidality with the 18-19-year-old subgroup, low education, prior abortion, physical abuse within the last 12 months were present, and most psychiatric disorders were associated with a higher suicidality prevalence. Additionally, after adjustment in the multivariate analysis, the style of parental bonding was independently associated with suicidality in the pregnant adolescent, with a PR of 2.53 (95 % CI 1.14-5.59) for the maternal 'affectionless control' and a PR of 2.91 (95 % CI 1.10-7.70) for the paternal 'neglectful parenting.' We found that maternal 'affectionless control' and paternal 'neglectful parenting' were independent predictors of suicidality in this sample of pregnant teenagers.

  5. Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies

    OpenAIRE

    Bastos, Laura Alves; Sousa, Ana Beatriz Silva; Drubi-Filho, Brahim; Panzeri Pires-de-Souza, Fernanda de Carvalho; Garcia, Lucas da Fonseca Roberti

    2014-01-01

    Objectives The aim of this study was to evaluate the effect of pre-etching on the bond strength of silorane-based composite specific adhesive system to dentin. Materials and Methods Thirty human molars were randomly divided into 5 groups according to the different bonding strategies. For teeth restored with silorane-based composite (Filtek Silorane, 3M ESPE), the specific self-etching adhesive system (Adhesive System P90, 3M ESPE) was used with and without pre-etching (Pre-etching/S...

  6. Theoretical Study on the Aza-Diels-Alder Reaction Catalyzed by PHCl2 Lewis Acid via Pnicogen Bonding.

    Science.gov (United States)

    Yaghoobi, Fereshteh; Sohrabi Mahboub, Mahdi

    2018-03-15

    The reaction mechanism of the Aza-Diels-Alder (A-D-A) cycloaddition reaction between X 2 C═NNH 2 , where X = H, F, Cl, Br, and 1,3-butadiene catalyzed by a PHCl 2 Lewis acid was characterized using density functional theory calculations. The influences of various substituents of X on the studied reaction were analyzed using the activation strain model (ASM), which is also termed as the distortion-interaction model. Calculations showed that the smallest and largest values of the activation energies belong to the substituents of F and Br, respectively. The activation energy of the studied reactions was decreased within 8.6 kcal·mol -1 in the presence of PHCl 2 catalyst. Investigations showed that the pnicogen bonding is adequately capable of activating the A-D-A reaction. The quantum theory of atoms in molecules (QTAIM) and natural bond orbital (NBO) analysis were implemented to understand the nature of C 4,Cbut ···C XIm and C 1,Cbut ···N XIm bonds at the TS structures. Additionally, the energy decomposition analysis (EDA) based on the ETS-NOCV scheme was used to characterize the nature of C 4,Cbut ···C XIm and C 1,Cbut ···N XIm bond. The results of the study mirror the fact that the PHCl 2 Lewis acid may be suggested as a simple suitable catalyst for experimental studies on the A-D-A reactions.

  7. A comparison of shear bond strength of orthodontic brackets bonded with four different orthodontic adhesives

    Science.gov (United States)

    Sharma, Sudhir; Tandon, Pradeep; Nagar, Amit; Singh, Gyan P; Singh, Alka; Chugh, Vinay K

    2014-01-01

    Objectives: The objective of this study is to compare the shear bond strength (SBS) of stainless steel (SS) orthodontic brackets bonded with four different orthodontic adhesives. Materials and Methods: Eighty newly extracted premolars were bonded to 0.022 SS brackets (Ormco, Scafati, Italy) and equally divided into four groups based on adhesive used: (1) Rely-a-Bond (self-cure adhesive, Reliance Orthodontic Product, Inc., Illinois, USA), (2) Transbond XT (light-cure adhesive, 3M Unitek, CA, USA), (3) Transbond Plus (sixth generation self-etch primer, 3M Unitek, CA, USA) with Transbond XT (4) Xeno V (seventh generation self-etch primer, Dentsply, Konstanz, Germany) with Xeno Ortho (light-cure adhesive, Dentsply, Konstanz, Germany) adhesive. Brackets were debonded with a universal testing machine (Model No. 3382 Instron Corp., Canton, Mass, USA). The adhesive remnant index (ARI) was recordedIn addition, the conditioned enamel surfaces were observed under a scanning electron microscope (SEM). Results: Transbond XT (15.49 MPa) attained the highest bond strength. Self-etching adhesives (Xeno V, 13.51 MPa; Transbond Plus, 11.57 MPa) showed clinically acceptable SBS values and almost clean enamel surface after debonding. The analysis of variance (F = 11.85, P adhesives left on the tooth) to be the most prevalent in Transbond XT (40%), followed by Rely-a-Bond (30%), Transbond Plus with Transbond XT (15%), and Xeno V with Xeno Ortho (10%). Under SEM, enamel surfaces after debonding of the brackets appeared porous when an acid-etching process was performed on the surfaces of Rely-a-Bond and Transbond XT, whereas with self-etching primers enamel presented smooth and almost clean surfaces (Transbond Plus and Xeno V group). Conclusion: All adhesives yielded SBS values higher than the recommended bond strength (5.9-7–8 MPa), Seventh generation self-etching primer Xeno V with Xeno Ortho showed clinically acceptable SBS and the least amount of residual adhesive left on the

  8. La displasia cemento ósea florida y su diagnóstico diferencial The Florid cemento-bony dysplasia and the differential diagnosis

    Directory of Open Access Journals (Sweden)

    Allan Ulisses Carvalho de Melo

    2011-09-01

    Full Text Available Las lesiones benignas fibro-óseas de los maxilares constituyen un grupo diverso de enfermedades con una característica histológica común: la sustitución de hueso normal por tejido compuesto de colágeno y fibroblastos, con cantidades variables de una sustancia mineral que puede ser de hueso, cemento o ambos. Estas lesiones incluyen la displasia fibrosa, la displasia cemento-ósea en sus variantes: periapical, focal o florida, el cementoma gigantiforme familiar y el fibroma osificante cemento-osificante. La osteomielitis es un proceso inflamatorio agudo o crónico de los espacios medulares o corticales del hueso, que se extiende más allá del sitio inicial de desenvolvimiento. La osteomielitis esclerosante difusa es más frecuente en adultos, principalmente en la mandíbula. Se presenta radiográficamente como una lesión radiopaca difusa adyacente a los dientes, que puede ser multifocal. El objetivo de este trabajo fue describir un caso inusual de lesión fibro-ósea, cuyo diagnóstico diferencial se hizo también con la osteomielitis de los maxilares. Se concluyó que las lesiones fibro-óseas benignas, presentaron muchas similitudes con respecto a sus aspectos clínicos, radiográficos e histológicos. Por lo tanto, es fundamental el análisis conjunto de estas informaciones para obtener un diagnóstico definitivo.The benign fibrous-bony lesions are a diverse group of diseases with common features: replacement of normal bone by tissue composed of collagen and fibroblasts, with variable amounts of a mineral substance that could be bone, cement or both. These lesions include the fibrous dysplasia, the periapical cement-bony dysplasia, focal or florid, familiar giant cementoma and ossifying fibroma (cement-ossifying. Osteomyelitis is an acute or chronic inflammatory process of medullar or cortical spaces of bone extending beyond the onset site of development. Diffuse sclerosing osteomyelitis involves to adults mainly the mandible and

  9. Comparative study on direct and indirect bracket bonding techniques regarding time length and bracket detachment

    Directory of Open Access Journals (Sweden)

    Jefferson Vinicius Bozelli

    2013-12-01

    Full Text Available OBJECTIVE: The aim of this study was to assess the time spent for direct (DBB - direct bracket bonding and indirect (IBB - indirect bracket bonding bracket bonding techniques. The time length of laboratorial (IBB and clinical steps (DBB and IBB as well as the prevalence of loose bracket after a 24-week follow-up were evaluated. METHODS: Seventeen patients (7 men and 10 women with a mean age of 21 years, requiring orthodontic treatment were selected for this study. A total of 304 brackets were used (151 DBB and 153 IBB. The same bracket type and bonding material were used in both groups. Data were submitted to statistical analysis by Wilcoxon non-parametric test at 5% level of significance. RESULTS: Considering the total time length, the IBB technique was more time-consuming than the DBB (p < 0.001. However, considering only the clinical phase, the IBB took less time than the DBB (p < 0.001. There was no significant difference (p = 0.910 for the time spent during laboratorial positioning of the brackets and clinical session for IBB in comparison to the clinical procedure for DBB. Additionally, no difference was found as for the prevalence of loose bracket between both groups. CONCLUSION: the IBB can be suggested as a valid clinical procedure since the clinical session was faster and the total time spent for laboratorial positioning of the brackets and clinical procedure was similar to that of DBB. In addition, both approaches resulted in similar frequency of loose bracket.

  10. BONDING ALUMINUM METALS

    Science.gov (United States)

    Noland, R.A.; Walker, D.E.

    1961-06-13

    A process is given for bonding aluminum to aluminum. Silicon powder is applied to at least one of the two surfaces of the two elements to be bonded, the two elements are assembled and rubbed against each other at room temperature whereby any oxide film is ruptured by the silicon crystals in the interface; thereafter heat and pressure are applied whereby an aluminum-silicon alloy is formed, squeezed out from the interface together with any oxide film, and the elements are bonded.

  11. Primary bony non-Hodgkin lymphoma of the cervical spine: a case report

    Directory of Open Access Journals (Sweden)

    Sedrak Mark F

    2010-02-01

    Full Text Available Abstract Introduction Non-Hodgkin lymphoma primarily originating from the bone is exceedingly rare. To our knowledge, this is the first report of primary bone lymphoma presenting with progressive cord compression from an origin in the cervical spine. Herein, we discuss the unusual location in this case, the presenting symptoms, and the management of this disease. Case presentation We report on a 23-year-old Caucasian-American man who presented with two months of night sweats, fatigue, parasthesias, and progressive weakness that had progressed to near quadriplegia. Magnetic resonance (MR imaging demonstrated significant cord compression seen primarily at C7. Surgical management, with corpectomy and dorsal segmental fusion, in combination with adjuvant chemotherapy and radiation therapy, halted the progression of the primary disease and preserved neurological function. Histological analysis demonstrated an aggressive anaplastic large cell lymphoma. Conclusion Isolated primary bony lymphoma of the spine is exceedingly rare. As in our case, the initial symptoms may be the result of progressive cervical cord compression. Anterior corpectomy with posterolateral decompression and fusion succeeded in preventing progressive neurologic decline and maintaining quality of life. The reader should be aware of the unique presentation of this disease and that surgical management is a successful treatment strategy.

  12. HR-EELS study of hydrogen bonding configuration, chemical and thermal stability of detonation nanodiamond films

    Energy Technology Data Exchange (ETDEWEB)

    Michaelson, Sh.; Akhvlediani, R. [Schulich Faculty of Chemistry, Technion-Israel Institute of Technology, Haifa 32000 (Israel); Petit, T.; Girard, H.A.; Arnault, J.C. [CEA, LIST, Diamond Sensors Laboratory, F-91191 Gif sur Yvette (France); Hoffman, A., E-mail: choffman@tx.technion.ac.il [Schulich Faculty of Chemistry, Technion-Israel Institute of Technology, Haifa 32000 (Israel)

    2014-06-01

    Nano-diamond films composed of 3–10 nm grains prepared by the detonation method and deposited onto silicon substrates by drop-casting were examined by high resolution electron energy loss spectroscopy (HR-EELS), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and secondary ion mass spectroscopy (SIMS). The impact of (i) ex-situ ambient annealing at 400 °C and (ii) ex-situ hydrogenation on hydrogen bonding and its thermal stability were examined. In order to clarify the changes in hydrogen bonding configuration detected on the different surfaces as a function of thermal annealing, in-situ hydrogenation by thermally activated atomic hydrogen was performed and examined. This study provides direct evidence that the exposure to ambient conditions and medium temperature ambient annealing have a pronounced effect on the hydrogen-carbon bonding configuration onto the nano-diamond surfaces. In-situ 1000 °C annealing results in irreversible changes of the film surface and partial nano-diamond silicidation.

  13. FTIR study of hydrogen bonding interaction between fluorinated alcohol and unsaturated esters

    Science.gov (United States)

    Sheng, Xia; Jiang, Xiaotong; Zhao, Hailiang; Wan, Dongjin; Liu, Yongde; Ngwenya, Cleopatra Ashley; Du, Lin

    2018-06-01

    The 1:1 complexes of two unsaturated esters with 2,2,2-trifluoroethanol (TFE) were investigated experimentally and computationally. The experimental observations of the spectral shifts of the OH-stretching vibrational transitions were obtained at 113 cm-1 for TFE-methyl acrylate (MA) and 92 cm-1 for TFE-vinyl acetate (VA). There are three docking sites in the two unsaturated esters for the incoming TFE. The predicted red shifts of the OH-stretching vibrational transitions were found to be larger for the Osbnd H⋯Odbnd C hydrogen bonded conformer than those for the Osbnd H⋯π and Osbnd H⋯O ones. The binding energies further prove that the Osbnd H⋯Odbnd C hydrogen bonded conformers are the most stable ones. On the basis of the DFT calculations as well as previous works, the carbonyl group is the best docking site for TFE. Furthermore, the thermodynamic equilibrium constants of TFE-MA and TFE-VA were obtained at 0.28 and 0.15 by combining the experimental spectra data and the DFT calculations. Consequently, the Gibbs free energies of formation were determined to be 3.2 and 4.8 kJ mol-1 for TFE-MA and TFE-VA, respectively. The quantum theory of atoms in molecules (AIM) and generalized Kohn-Sham energy decomposition analysis (GKS-EDA) were carried out for further characterization of the hydrogen bonding interactions. GKS-EDA shows an "electrostatic" dominated hydrogen bonding character for the Osbnd H⋯Odbnd C hydrogen bonds.

  14. A Carapace-Like Bony ‘Body Tube’ in an Early Triassic Marine Reptile and the Onset of Marine Tetrapod Predation

    Science.gov (United States)

    Chen, Xiao-hong; Motani, Ryosuke; Cheng, Long; Jiang, Da-yong; Rieppel, Olivier

    2014-01-01

    Parahupehsuchus longus is a new species of marine reptile from the Lower Triassic of Yuan’an County, Hubei Province, China. It is unique among vertebrates for having a body wall that is completely surrounded by a bony tube, about 50 cm long and 6.5 cm deep, comprising overlapping ribs and gastralia. This tube and bony ossicles on the back are best interpreted as anti-predatory features, suggesting that there was predation pressure upon marine tetrapods in the Early Triassic. There is at least one sauropterygian that is sufficiently large to feed on Parahupehsuchus in the Nanzhang-Yuan’an fauna, together with six more species of potential prey marine reptiles with various degrees of body protection. Modern predators of marine tetrapods belong to the highest trophic levels in the marine ecosystem but such predators did not always exist through geologic time. The indication of marine-tetrapod feeding in the Nanzhang-Yuan’an fauna suggests that such a trophic level emerged for the first time in the Early Triassic. The recovery from the end-Permian extinction probably proceeded faster than traditionally thought for marine predators. Parahupehsuchus has superficially turtle-like features, namely expanded ribs without intercostal space, very short transverse processes, and a dorsal outgrowth from the neural spine. However, these features are structurally different from their turtle counterparts. Phylogeny suggests that they are convergent with the condition in turtles, which has a fundamentally different body plan that involves the folding of the body wall. Expanded ribs without intercostal space evolved at least twice and probably even more among reptiles. PMID:24718682

  15. Uranium(III)-carbon multiple bonding supported by arene δ-bonding in mixed-valence hexauranium nanometre-scale rings.

    Science.gov (United States)

    Wooles, Ashley J; Mills, David P; Tuna, Floriana; McInnes, Eric J L; Law, Gareth T W; Fuller, Adam J; Kremer, Felipe; Ridgway, Mark; Lewis, William; Gagliardi, Laura; Vlaisavljevich, Bess; Liddle, Stephen T

    2018-05-29

    Despite the fact that non-aqueous uranium chemistry is over 60 years old, most polarised-covalent uranium-element multiple bonds involve formal uranium oxidation states IV, V, and VI. The paucity of uranium(III) congeners is because, in common with metal-ligand multiple bonding generally, such linkages involve strongly donating, charge-loaded ligands that bind best to electron-poor metals and inherently promote disproportionation of uranium(III). Here, we report the synthesis of hexauranium-methanediide nanometre-scale rings. Combined experimental and computational studies suggest overall the presence of formal uranium(III) and (IV) ions, though electron delocalisation in this Kramers system cannot be definitively ruled out, and the resulting polarised-covalent U = C bonds are supported by iodide and δ-bonded arene bridges. The arenes provide reservoirs that accommodate charge, thus avoiding inter-electronic repulsion that would destabilise these low oxidation state metal-ligand multiple bonds. Using arenes as electronic buffers could constitute a general synthetic strategy by which to stabilise otherwise inherently unstable metal-ligand linkages.

  16. Surface Reconstruction-Induced Coincidence Lattice Formation Between Two-Dimensionally Bonded Materials and a Three-Dimensionally Bonded Substrate

    NARCIS (Netherlands)

    Boschker, Jos E.; Momand, Jamo; Bragaglia, Valeria; Wang, Ruining; Perumal, Karthick; Giussani, Alessandro; Kooi, Bart J.; Riechert, Henning; Calarco, Raffaella

    Sb2Te3 films are used for studying the epitaxial registry between two-dimensionally bonded (2D) materials and three-dimensional bonded (3D) substrates. In contrast to the growth of 3D materials, it is found that the formation of coincidence lattices between Sb2Te3 and Si(111) depends on the geometry

  17. Bond length and electric current oscillation of long linear carbon chains: Density functional theory, MpB model, and quantum spin transport studies

    International Nuclear Information System (INIS)

    Oeiras, R. Y.; Silva, E. Z. da

    2014-01-01

    Carbon linear atomic chains attached to graphene have experimentally been produced. Motivated by these results, we study the nature of the carbon bonds in these nanowires and how it affects their electrical properties. In the present study we investigate chains with different numbers of atoms and we observe that nanowires with odd number of atoms present a distinct behavior than the ones with even numbers. Using graphene nanoribbons as leads, we identify differences in the quantum transport of the chains with the consequence that even and odd numbered chains have low and high electrical conduction, respectively. We also noted a dependence of current with the wire size. We study this unexpected behavior using a combination of first principles calculations and simple models based on chemical bond theory. From our studies, the electrons of carbon nanowires present a quasi-free electron behavior and this explains qualitatively the high electrical conduction and the bond lengths with unexpected values for the case of odd nanowires. Our study also allows the understanding of the electric conduction dependence with the number of atoms and their parity in the chain. In the case of odd number chains a proposed π-bond (MpB) model describes unsaturated carbons that introduce a mobile π-bond that changes dramatically the structure and transport properties of these wires. Our results indicate that the nature of bonds plays the main role in the oscillation of quantum electrical conduction for chains with even and odd number of atoms and also that nanowires bonded to graphene nanoribbons behave as a quasi-free electron system, suggesting that this behavior is general and it could also remain if the chains are bonded to other materials

  18. Theoretical study of ZnO adsorption and bonding on Al2O3 (0001) surface

    Institute of Scientific and Technical Information of China (English)

    LI Yanrong; YANG Chun; XUE Weidong; LI Jinshan; LIU Yonghua

    2004-01-01

    ZnO adsorption on sapphire (0001) surface is theoretically calculated by using a plane wave ultrasoft pseudo-potential method based on ab initio molecular dynamics. The results reveal that the surface relaxation in the first layer Al-O is reduced, even eliminated after the surface adsorption of ZnO, and the chemical bonding energy is 434.3(±38.6) kJ·mol-1. The chemical bond of ZnO (0.185 ± 0.01 nm) has a 30° angle away from the adjacent Al-O bond, and the stable chemical adsorption position of the Zn is deflected from the surface O-hexagonal symmetry with an angle of about 30°. The analysis of the atomic populations, density of state and bonding electronic density before and after the adsorption indicates that the chemical bond formed by the O2- of the ZnO and the surface Al3+ has a strong ionic bonding characteristic, while the chemical bond formed by the Zn2+ and the surface O2- has an obvious covalent characteristic, which comes mainly from the hybridization of the Zn 4s and the O 2p and partially from that of the Zn 3d and the O 2p.

  19. Crystallographic and infrared spectroscopic study of bond distances in Ln[Fe(CN)6].4H2O (Ln=lanthanide)

    International Nuclear Information System (INIS)

    Zhou Xianju; Wong, W.-T.; Faucher, Michele D.; Tanner, Peter A.

    2008-01-01

    Along with crystallographic data of Ln[Fe(CN) 6 ].4H 2 O (Ln=lanthanide), the infrared spectra are reassigned to examine bond length trends across the series of Ln. The changes in mean Ln-O, Ln-N, C≡N and Fe-C distances are discussed and the bond natures of Ln-N and Ln-O are studied by bond length linear or quadratic fitting and comparisons with relevant ionic radii. The two different C≡N bond distances have been simulated by the covalo-electrostatic model. - Graphical abstract: Crystallographic and FTIR data for Ln[Fe(CN) 6 ].4H 2 O enable the changes in Ln-O, Ln-N, C≡N and Fe-C distances to be determined and modeled across the lanthanide series

  20. DNA Self-Assembly and Computation Studied with a Coarse-grained Dynamic Bonded Model

    DEFF Research Database (Denmark)

    Svaneborg, Carsten; Fellermann, Harold; Rasmussen, Steen

    2012-01-01

    We utilize a coarse-grained directional dynamic bonding DNA model [C. Svaneborg, Comp. Phys. Comm. (In Press DOI:10.1016/j.cpc.2012.03.005)] to study DNA self-assembly and DNA computation. In our DNA model, a single nucleotide is represented by a single interaction site, and complementary sites can...

  1. Posterior urethral injuries associated with motorcycle accidents and pelvic trauma in adolescents: analysis of urethral lesions occurring prior to a bony fracture using a computerized finite-element model.

    Science.gov (United States)

    Bréaud, J; Montoro, J; Lecompte, J F; Valla, J S; Loeffler, J; Baqué, P; Brunet, C; Thollon, L

    2013-02-01

    Adolescent males involved in motorcycle accidents are particularly at risk for pelvic injury, which may provoke a posterior urethral injury. The aim of this study was to develop a model to analyze the association between injuries and fractures of the pelvic ring and the risk of posterior urethral injury. Based on experience with traffic accident modeling, a computerized finite-element model was extrapolated from a computerized tomography scan of a 15-year-old boy. The anatomic structures concerned in urethral and pelvic ring trauma were isolated, rendered in 3D and given biomechanical properties. The model was verified according to available experiments on pelvic ring trauma. To apply the model, we recreated three impact mechanisms on the pelvic ring: lateral impact, antero-posterior impact and a real car‒motorcycle accident situation (postero-lateral impact). In all three situations, stretching of the posterior urethra was identified prior to bony fracture visualization. Application of this model allowed us to analyze precisely the link between trauma of the pelvic ring and lesions of the posterior urethra. The results should help to establish guidelines for urethral catheterization in male adolescents in cases of pelvic trauma, even when no bony fracture is present, in order to prevent iatrogenic worsening of a misdiagnosed posterior urethral trauma. Copyright © 2011 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  2. Vibrational signatures of cation-anion hydrogen bonding in ionic liquids: a periodic density functional theory and molecular dynamics study.

    Science.gov (United States)

    Mondal, Anirban; Balasubramanian, Sundaram

    2015-02-05

    Hydrogen bonding in alkylammonium based protic ionic liquids was studied using density functional theory (DFT) and ab initio molecular dynamics (AIMD) simulations. Normal-mode analysis within the harmonic approximation and power spectra of velocity autocorrelation functions were used as tools to obtain the vibrational spectra in both the gas phase and the crystalline phases of these protic ionic liquids. The hydrogen bond vibrational modes were identified in the 150-240 cm(-1) region of the far-infrared (far-IR) spectra. A blue shift in the far-IR mode was observed with an increasing number of hydrogen-bonding sites on the cation; the exact peak position is modulated by the cation-anion hydrogen bond strength. Sub-100 cm(-1) bands in the far-IR spectrum are assigned to the rattling motion of the anions. Calculated NMR chemical shifts of the acidic protons in the crystalline phase of these salts also exhibit the signature of cation-anion hydrogen bonding.

  3. Hydrogen bond nature of ferroelectric material studied by X-ray and neutron diffraction. Electric dipole moment and proton tunneling

    International Nuclear Information System (INIS)

    Noda, Yukio; Kiyanagi, Ryoji; Mochida, Tomoyuki; Sugawara, Tadashi

    2006-01-01

    Hydrogen bond nature of MeHPLN and BrHPLN is studied using x-ray and neutron diffraction technique. We found that electric dipole moment of hydrogen atom plays an important role for the phase transition, and proton tunneling model is confirmed on this isolated hydrogen bond system. (author)

  4. Report of the specialists' workshop on phase transition studies on hydrogen-bonded crystals by neutron and X-ray diffractometries

    International Nuclear Information System (INIS)

    Tokunaga, M.; Shibuya, I.

    1989-01-01

    The report carries a total of 15 studies on hydrogen-bonded crystals made by means of neutron/X-ray diffraction which were presented at a technical study meeting held on December 12 and 13, 1988, at the Research Reactor Institute of Kyoto University. The report covers 'introduction', 'linear relation between transition temperature and hydrogen-bond length in KDP type crystals', 'X-ray study of crystal structure under high pressure in DKDP', 'crystal structure of ADP in the paraelectric phase', 'crystal structure of Rochelle salt in the paraelectric phase', 'distortion of AsO 4 in KDA', 'study of phase transition in KDP family by dielectric dispersion', 'dielectric relaxation and phase transition in ice Ih', 'Raman scattering study of KDP', 'mechanism of phase transition in KDP by Raman scattering study under high pressure-reinvestigation of the Peercy's conclusion', 'localized modes of proton in KDP', 'hyper-Raman scattering study of hydrogen-bonded crystals', 'phase transition of CDP', 'the 180deg law in phase diagram', and 'comments'. (N.K.)

  5. Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies.

    Science.gov (United States)

    Bastos, Laura Alves; Sousa, Ana Beatriz Silva; Drubi-Filho, Brahim; Panzeri Pires-de-Souza, Fernanda de Carvalho; Garcia, Lucas da Fonseca Roberti

    2015-02-01

    The aim of this study was to evaluate the effect of pre-etching on the bond strength of silorane-based composite specific adhesive system to dentin. Thirty human molars were randomly divided into 5 groups according to the different bonding strategies. For teeth restored with silorane-based composite (Filtek Silorane, 3M ESPE), the specific self-etching adhesive system (Adhesive System P90, 3M ESPE) was used with and without pre-etching (Pre-etching/Silorane and Silorane groups). Teeth restored with methacrylate based-composite (Filtek Z250, 3M ESPE) were hybridized with the two-step self-etching system (Clearfil SE Bond, Kuraray), with and without pre-etching (Pre-etching/Methacrylate and Methacrylate groups), or three-step adhesive system (Adper Scotchbond Multi-Purpose, 3M ESPE) (Three-step/Methacrylate group) (n = 6). The restored teeth were sectioned into stick-shaped test specimens (1.0 × 1.0 mm), and coupled to a universal test machine (0.5 mm/min) to perform microtensile testing. Pre-etching/Methacrylate group presented the highest bond strength values, with significant difference from Silorane and Three-step/Methacrylate groups (p adhesive system to dentin.

  6. Expected Business Conditions and Bond Risk Premia

    DEFF Research Database (Denmark)

    Eriksen, Jonas Nygaard

    2017-01-01

    In this article, I study the predictability of bond risk premia by means of expectations to future business conditions using survey forecasts from the Survey of Professional Forecasters. I show that expected business conditions consistently affect excess bond returns and that the inclusion of exp...

  7. A comparative study of shear bond strength of orthodontic bracket after acid-etched and Er:YAG treatment on enamel surface

    Science.gov (United States)

    Leão, Juliana C.; Mota, Cláudia C. B. O.; Cassimiro-silva, Patricia F.; Gomes, Anderson S. L.

    2016-02-01

    This study aimed to evaluate the shear bond strength (SBS) of teeth prepared for orthodontic bracket bonding with 37% phosphoric acid and Er:YAG laser. Forty bovine incisors were divided into two groups. In Group I, the teeth were conditioned with 37% phosphoric acid and brackets were bonded with Transbond XT; in Group II, the teeth were irradiated with Er:YAG and bonding with Transbond XT. After SBS test, the adhesive remnant index was determined. Adhesion to dental hard tissues after Er:YAG laser etching was inferior to that obtained after acid etching but exceeded what is believed to be clinically sufficient strength, and therefore can be used in patients.

  8. Phenylacetylene and H bond

    Indian Academy of Sciences (India)

    ... all resembling H bonds. Non-linear H bonds due to secondary interactions. C-H stretching frequency shows blue shift. Heavy atom distances are longer than the sum of van der Waals radii. Formed a task group through IUPAC to come up with a modern definition of H bond. 15 international experts including Desiraju.

  9. Origin of the X-Hal (Hal = Cl, Br) bond-length change in the halogen-bonded complexes.

    Science.gov (United States)

    Wang, Weizhou; Hobza, Pavel

    2008-05-01

    The origin of the X-Hal bond-length change in the halogen bond of the X-Hal...Y type has been investigated at the MP2(full)/6-311++G(d,p) level of theory using a natural bond orbital analysis, atoms in molecules procedure, and electrostatic potential fitting methods. Our results have clearly shown that various theories explaining the nature of the hydrogen bond cannot be applied to explain the origin of the X-Hal bond-length change in the halogen bond. We provide a new explanation for this change. The elongation of the X-Hal bond length is caused by the electron-density transfer to the X-Hal sigma* antibonding orbital. For the blue-shifting halogen bond, the electron-density transfer to the X-Hal sigma* antibonding orbital is only of minor importance; it is the electrostatic attractive interaction that causes the X-Hal bond contraction.

  10. Chemical Bond Energies of 3d Transition Metals Studied by Density Functional Theory

    DEFF Research Database (Denmark)

    Moltved, Klaus A.d; Kepp, Kasper P.

    2018-01-01

    Despite their vast importance to inorganic chemistry, materials science and catalysis, the accuracy of modelling the formation or cleavage of metal-ligand (M-L) bonds depends greatly on the chosen functional and the type of bond in a way that is not systematically understood. In order to approach...

  11. Spectroscopic study of uracil, 1-methyluracil and 1-methyl-4-thiouracil: Hydrogen bond interactions in crystals and ab-initio molecular dynamics

    Science.gov (United States)

    Brela, Mateusz Z.; Boczar, Marek; Malec, Leszek M.; Wójcik, Marek J.; Nakajima, Takahito

    2018-05-01

    Hydrogen bond networks in uracil, 1-methyluracil and 1-methyl-4-thiouracil were studied by ab initio molecular dynamics as well as analysis of the orbital interactions. The power spectra calculated by ab initio molecular dynamics for atoms involved in hydrogen bonds were analyzed. We calculated spectra by using anharmonic approximation based on the autocorrelation function of the atom positions obtained from the Born-Oppenheimer simulations. Our results show the differences between hydrogen bond networks in uracil and its methylated derivatives. The studied methylated derivatives, 1-methyluracil as well as 1-methyl-4-thiouracil, form dimeric structures in the crystal phase, while uracil does not form that kind of structures. The presence of sulfur atom instead oxygen atom reflects weakness of the hydrogen bonds that build dimers.

  12. Hybrid layer difference between sixth and seventh generation bonding agent

    Directory of Open Access Journals (Sweden)

    Grace Syavira Suryabrata

    2006-03-01

    Full Text Available Since etching is completed at the same stage as priming and bonding, when applying the sixth and seventh generation bonding, the exposed smear layers are constantly surrounded by primer and bonding and cannot collapse. The smear layer and the depth of penetration of resin bonding in dentinal tubules are completely integrated into hybrid layer. The purpose of this laboratory research was to study the penetration depth of two self etching adhesive. Fourteen samples of human extracted teeth were divided into two groups. Each groups consisted of seven samples, each of them was treated with sixth generation bonding agent and the other was treated with seventh generation bonding agent. The results disclosed that the penetration into dentinal tubules of seventh generation bonding agent was deeper than sixth generation bonding agent. Conclusion: bond strength will improve due to the increasing of penetration depth of resin bonding in dentinal tubules.

  13. Additional disulfide bonds in insulin

    DEFF Research Database (Denmark)

    Vinther, Tine N; Pettersson, Ingrid; Huus, Kasper

    2015-01-01

    The structure of insulin, a glucose homeostasis-controlling hormone, is highly conserved in all vertebrates and stabilized by three disulfide bonds. Recently, we designed a novel insulin analogue containing a fourth disulfide bond located between positions A10-B4. The N-terminus of insulin's B......-chain is flexible and can adapt multiple conformations. We examined how well disulfide bond predictions algorithms could identify disulfide bonds in this region of insulin. In order to identify stable insulin analogues with additional disulfide bonds, which could be expressed, the Cβ cut-off distance had...... in comparison to analogues with additional disulfide bonds that were more difficult to predict. In contrast, addition of the fourth disulfide bond rendered all analogues resistant to fibrillation under stress conditions and all stable analogues bound to the insulin receptor with picomolar affinities. Thus...

  14. Probing hydrogen bonding interactions and proton transfer in proteins

    Science.gov (United States)

    Nie, Beining

    Scope and method of study. Hydrogen bonding is a fundamental element in protein structure and function. Breaking a single hydrogen bond may impair the stability of a protein. It is therefore important to probe dynamic changes in hydrogen bonding interactions during protein folding and function. Time-resolved Fourier transform infrared spectroscopy is highly sensitive to hydrogen bonding interactions. However, it lacks quantitative correlation between the vibrational frequencies and the number, type, and strength of hydrogen bonding interactions of ionizable and polar residues. We employ quantum physics theory based ab initio calculations to study the effects of hydrogen bonding interactions on vibrational frequencies of Asp, Glu, and Tyr residues and to develop vibrational spectral markers for probing hydrogen bonding interactions using infrared spectroscopy. In addition, proton transfer process plays a crucial role in a wide range of energy transduction, signal transduction, and enzymatic reactions. We study the structural basis for proton transfer using photoactive yellow protein as an excellent model system. Molecular dynamics simulation is employed to investigate the structures of early intermediate states. Quantum theory based ab initio calculations are used to study the impact of hydrogen bond interactions on proton affinity and proton transfer. Findings and conclusions. Our extensive density function theory based calculations provide rich structural, spectral, and energetic information on hydrogen bonding properties of protonated side chain groups of Asp/Glu and Tyr. We developed vibrational spectral markers and 2D FTIR spectroscopy for structural characterization on the number and the type of hydrogen bonding interactions of the COOH group of Asp/Glu and neutral phenolic group of Tyr. These developments greatly enhance the power of time-resolved FTIR spectroscopy as a major experimental tool for structural characterization of functionally important

  15. Continuous feelings of love? The parental bond from pregnancy to toddlerhood.

    Science.gov (United States)

    de Cock, Evi S A; Henrichs, Jens; Vreeswijk, Charlotte M J M; Maas, A Janneke B M; Rijk, Catharina H A M; van Bakel, Hedwig J A

    2016-02-01

    Both prenatal and postnatal parental bonding (i.e., the affective tie from parent to child) have important effects on parental and child functioning. However, research on the continuity and correlates of parental bonding is lacking. Therefore, the goal of the present study was to examine the stability of bonding levels and to explore distinct bonding patterns with a latent class analysis. Moreover, the correlates of these bonding patterns in the parental-, child-, and contextual domain were studied. Levels of maternal (N = 370) and paternal (N = 292) bonding and potential correlates were assessed at 26 weeks of pregnancy, 6 months, and 24 months postpartum. Results showed moderate stability of bonding from pregnancy to toddlerhood. For both mothers and fathers, 4 distinct bonding patterns were found. Parents with low bonding patterns were characterized by increased anxiety and parenting stress, less partner support, less adaptive personality profiles, and children with difficult temperament. These findings indicate the importance of monitoring young children's parents with poor levels of bonding as their bonding patterns remain stable from pregnancy until toddlerhood and because those parents experience problems in multiple domains. (c) 2016 APA, all rights reserved).

  16. Comparison of bond strengths of ceramic brackets bonded to zirconia surfaces using different zirconia primers and a universal adhesive.

    Science.gov (United States)

    Lee, Ji-Yeon; Ahn, Jaechan; An, Sang In; Park, Jeong-Won

    2018-02-01

    The aim of this study is to compare the shear bond strengths of ceramic brackets bonded to zirconia surfaces using different zirconia primers and universal adhesive. Fifty zirconia blocks (15 × 15 × 10 mm, Zpex, Tosoh Corporation) were polished with 1,000 grit sand paper and air-abraded with 50 µm Al 2 O 3 for 10 seconds (40 psi). They were divided into 5 groups: control (CO), Metal/Zirconia primer (MZ, Ivoclar Vivadent), Z-PRIME Plus (ZP, Bisco), Zirconia Liner (ZL, Sun Medical), and Scotchbond Universal adhesive (SU, 3M ESPE). Transbond XT Primer (used for CO, MZ, ZP, and ZL) and Transbond XT Paste was used for bracket bonding (Gemini clear ceramic brackets, 3M Unitek). After 24 hours at 37°C storage, specimens underwent 2,000 thermocycles, and then, shear bond strengths were measured (1 mm/min). An adhesive remnant index (ARI) score was calculated. The data were analyzed using one-way analysis of variance and the Bonferroni test ( p = 0.05). Surface treatment with primers resulted in increased shear bond strength. The SU group showed the highest shear bond strength followed by the ZP, ZL, MZ, and CO groups, in that order. The median ARI scores were as follows: CO = 0, MZ = 0, ZP = 0, ZL = 0, and SU = 3 ( p < 0.05). Within this experiment, zirconia primer can increase the shear bond strength of bracket bonding. The highest shear bond strength is observed in SU group, even when no primer is used.

  17. Effect of Sodium Ascorbate and Delayed Bonding on the Bond Strength of Silorane and Two-step Self-etch Adhesive Systems in Bleached Enamel

    Directory of Open Access Journals (Sweden)

    Mehdi Abed Kahnemooyi

    2014-12-01

    Full Text Available Background and aims. Studies have shown decreased bond strength of composite resin to human and bovine bleached enamel. This study evaluated the effect of sodium ascorbate and delayed bonding on the bond strength of two adhesive systems to bleached enamel. Materials and methods. The labial surfaces of 150 sound bovine incisor teeth were abraded with abrasive paper. The teeth were randomly divided into 8 groups: A: control; B: bleached with 35% hydrogen peroxide; C: bleached with 35% hydrogen peroxide + sodium ascorbate gel; and D: bleached with 35% hydrogen peroxide + delayed bonding. In groups A‒D, silorane adhesive system and Filtek silorane composite resin were used. In groups E‒H, the same preparation methods of groups A‒D were used. Two-step self-etch Clearfil SE Bond adhesive systems and AP-X composite resin were administered. Shear bond strength of each group was measured. Two samples were prepared for each surface preparation for ultrastructural evaluation. Two-way ANOVA and Tukey test were used for data analysis at P<0.05. Results. The interaction between the adhesive system type and surface preparation protocol was significant (P=0.014, with significant differences in shear bond strengths in terms of the adhesive systems (P<0.01. There were significant differences in shear bond strength in terms of surface preparation techniques irrespective of the adhesive system (P<0.01. Conclusion. The results showed that bleaching with 35% hydrogen peroxide decreased the shear bond strength values with both adhesive systems, and a one-week delay in bonding and 10% sodium ascorbate for 10 minutes restored the bond strength in both adhesive systems.

  18. Study of Diffusion Bonding of 45 Steel through the Compacted Nickel Powder Layer

    Science.gov (United States)

    Zeer, G. M.; Zelenkova, E. G.; Temnykh, V. I.; Tokmin, A. M.; Shubin, A. A.; Koroleva, Yu. P.; Mikheev, A. A.

    2018-02-01

    The microstructure of the transition zone and powder spacer, the concentration distribution of chemical elements over the width of the diffusion-bonded joint, and microhardness of 45 steel-compacted Ni powder spacer-45 steel layered composites formed by diffusion bonding have been investigated. It has been shown that the relative spacer thickness χ compacting pressure of 500 MPa. The solid-state diffusion bonding is accompanied by sintering the nickel powder spacer and the formation of the transition zone between the spacer and steel. The transition zone consists of solid solution of nickel in the α-Fe phase and ordered solid solution of iron in nickel (FeNi3).

  19. Engineering Performance of Polyurethane Bonded Aggregates

    Directory of Open Access Journals (Sweden)

    Haimin WU

    2017-08-01

    Full Text Available In this paper the engineering performance of polyurethane (PUR bonded aggregate were studied. The engineering performance, including compressive and flexural mechanical properties, void ratio, and coefficient of permeability were determined through laboratory tests. Moreover, the effects of two different curing conditions on the compressive strength properties of a PUR bonded aggregate were also evaluated. The compressive strengths of PUR bonded aggregates were found to be lower than that of conventional porous concrete, which is a commonly used cushion material. However, experimental results indicated a higher void ratio and coefficient of permeability, lower elasticity modulus, better toughness, and stronger adaptability to flexural deformation compared to porous concrete. Consequently, PUR bonded aggregate is a better solution than porous concrete when used as the cushion material of a geomembrane surface barrier for a high rock-fill dam.DOI: http://dx.doi.org/10.5755/j01.ms.23.2.15798

  20. Dopamine in the medial amygdala network mediates human bonding.

    Science.gov (United States)

    Atzil, Shir; Touroutoglou, Alexandra; Rudy, Tali; Salcedo, Stephanie; Feldman, Ruth; Hooker, Jacob M; Dickerson, Bradford C; Catana, Ciprian; Barrett, Lisa Feldman

    2017-02-28

    Research in humans and nonhuman animals indicates that social affiliation, and particularly maternal bonding, depends on reward circuitry. Although numerous mechanistic studies in rodents demonstrated that maternal bonding depends on striatal dopamine transmission, the neurochemistry supporting maternal behavior in humans has not been described so far. In this study, we tested the role of central dopamine in human bonding. We applied a combined functional MRI-PET scanner to simultaneously probe mothers' dopamine responses to their infants and the connectivity between the nucleus accumbens (NAcc), the amygdala, and the medial prefrontal cortex (mPFC), which form an intrinsic network (referred to as the "medial amygdala network") that supports social functioning. We also measured the mothers' behavioral synchrony with their infants and plasma oxytocin. The results of this study suggest that synchronous maternal behavior is associated with increased dopamine responses to the mother's infant and stronger intrinsic connectivity within the medial amygdala network. Moreover, stronger network connectivity is associated with increased dopamine responses within the network and decreased plasma oxytocin. Together, these data indicate that dopamine is involved in human bonding. Compared with other mammals, humans have an unusually complex social life. The complexity of human bonding cannot be fully captured in nonhuman animal models, particularly in pathological bonding, such as that in autistic spectrum disorder or postpartum depression. Thus, investigations of the neurochemistry of social bonding in humans, for which this study provides initial evidence, are warranted.

  1. Love Thy Neighbor: Bonding versus Bridging Trust

    OpenAIRE

    Poulsen, Odile; Svendsen, Gert Tinggaard

    2005-01-01

    We study how trust is generated in society. In a two-sector model, we analyze two communities. In the bonding community people do not trust people outside their regular networks. In the bridging community people choose to trust strangers when they meet them. The hypothesis is that when trust is only bonding, it cannot accumulate. Our theoretical contribution is to show that when trust is only bonding then the economy’s level of trust moves to an unstable equilibrium that may under certain con...

  2. A study on the compatibility between one-bottle dentin adhesives and composite resins using micro-shear bond strength.

    Science.gov (United States)

    Song, Minju; Shin, Yooseok; Park, Jeong-Won; Roh, Byoung-Duck

    2015-02-01

    This study was performed to determine whether the combined use of one-bottle self-etch adhesives and composite resins from same manufacturers have better bond strengths than combinations of adhesive and resins from different manufacturers. 25 experimental micro-shear bond test groups were made from combinations of five dentin adhesives and five composite resins with extracted human molars stored in saline for 24 hr. Testing was performed using the wire-loop method and a universal testing machine. Bond strength data was statistically analyzed using two way analysis of variance (ANOVA) and Tukey's post hoc test. Two way ANOVA revealed significant differences for the factors of dentin adhesives and composite resins, and significant interaction effect (p composite resin (p composite resin than other manufacturer's composite resin. Not all combinations of adhesive and composite resin by same manufacturers failed to show significantly higher bond strengths than mixed manufacturer combinations.

  3. Hindered Csbnd N bond rotation in triazinyl dithiocarbamates

    Science.gov (United States)

    Jung, Taesub; Do, Hee-Jin; Son, Jongwoo; Song, Jae Hee; Cha, Wansik; Kim, Yeong-Joon; Lee, Kyung-Koo; Kwak, Kyungwon

    2018-01-01

    The substituent and solvent effects on the rotation around a Csbnd N amide bond were studied for a series of triazine dibenzylcarbamodithioates. The Gibbs free energies (ΔG‡) were measured to be 16-18 kcal/mol in DMSO-d6 and toluene-d8 using variable-temperature nuclear magnetic resonance (VT-1H NMR) spectroscopy. Density functional theory (DFT) calculations reproduced the experimental observations with various substituents, as well as solvents. From the detailed analysis of the DFT results, we found that the electron donating dibenzyl amine group increased the electron population on the triazinyl ring, which decreased the rotational barrier of the Csbnd N bond in the dithiocarbamate group attached to the triazinyl ring. The higher electron population on the triazine moiety stabilizes the partial double bond character of the Ssbnd C bond, which competitively excludes the double bond character of the Csbnd N bond. Therefore, the rotational dynamics of the Csbnd N bond in dithiocarbamates can be a sensitive probe to small differences in the electron population of substituents on sulfur.

  4. Studies on in situ magnetic alignment of bonded anisotropic Nd-Fe-B alloy powders

    Energy Technology Data Exchange (ETDEWEB)

    Nlebedim, I.C. [Ames Laboratory, Ames, IA 50011 (United States); Ucar, Huseyin; Hatter, Christine B. [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); McCallum, R.W. [Ames Laboratory, Ames, IA 50011 (United States); McCall, Scott K. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Kramer, M.J. [Ames Laboratory, Ames, IA 50011 (United States); Paranthaman, M. Parans [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States)

    2017-01-15

    Considerations for achieving high degree of alignment in polymer bonded permanent magnets are presented via the results of a study on in situ magnetic alignment of anisotropic Nd-Fe-B magnet powders. Contributions from effect of the alignment temperature, alignment magnetic field and the properties of the polymer on the hard magnetic properties of the bonded magnet were considered. The thermo-rheological properties of the polymer and the response of the magnet powders to the applied magnetic field indicate that hard magnetic properties were optimized at an alignment temperature just above the melting temperature of the EVA co-polymer. This agrees with an observed correlation between the change in magnetization due to improved magnetic alignment of the anisotropic powders and the change in viscosity of the binder. Manufacturing cost can be minimized by identifying optimum alignment temperatures and magnetic field strengths. - Highlights: • Optimum alignment of anisotropic magnet powders can enable high performance bonded magnets. • The viscoelastic state of polymer binders determines the dominating coercivity mechanism. • The minimum deviation in coercivity and remanence, with magnetic field, can occur at different temperatures. • Melting characteristics of polymer binders and the change in magnetization during alignment can be correlated.

  5. Studies on in situ magnetic alignment of bonded anisotropic Nd-Fe-B alloy powders

    International Nuclear Information System (INIS)

    Nlebedim, I.C.; Ucar, Huseyin; Hatter, Christine B.; McCallum, R.W.; McCall, Scott K.; Kramer, M.J.; Paranthaman, M. Parans

    2017-01-01

    Considerations for achieving high degree of alignment in polymer bonded permanent magnets are presented via the results of a study on in situ magnetic alignment of anisotropic Nd-Fe-B magnet powders. Contributions from effect of the alignment temperature, alignment magnetic field and the properties of the polymer on the hard magnetic properties of the bonded magnet were considered. The thermo-rheological properties of the polymer and the response of the magnet powders to the applied magnetic field indicate that hard magnetic properties were optimized at an alignment temperature just above the melting temperature of the EVA co-polymer. This agrees with an observed correlation between the change in magnetization due to improved magnetic alignment of the anisotropic powders and the change in viscosity of the binder. Manufacturing cost can be minimized by identifying optimum alignment temperatures and magnetic field strengths. - Highlights: • Optimum alignment of anisotropic magnet powders can enable high performance bonded magnets. • The viscoelastic state of polymer binders determines the dominating coercivity mechanism. • The minimum deviation in coercivity and remanence, with magnetic field, can occur at different temperatures. • Melting characteristics of polymer binders and the change in magnetization during alignment can be correlated.

  6. Green and social bonds - A promising tool

    International Nuclear Information System (INIS)

    Blanc, Dominique; Barochez, Aurelie de; Cozic, Aela

    2013-11-01

    Issues of green bonds, socially responsible bonds and climate bonds are on the rise. Novethic estimates that some Euro 5 billion in such bonds has been issued since the start of 2013 by development banks, the main issuers of this type of debt. The figure is equal to over half of their total issues since 2007. Including local authorities, corporations and banks, a total Euro 8 billion of these bonds has been issued thus far in 2013. Given the size of the bond market, which the OECD estimated at Euro 95,000 billion in 2011, green and social bonds are still something of a niche but have strong growth potential. A number of large issues, from Euro 500 million to Euro 1 billion, were announced at the end of the year. Unlike conventional bonds, green and social bonds are not intended to finance all the activities of the issuer or refinance its debt. They serve instead to finance specific projects, such as producing renewable energy or adapting to climate change, the risk of which is shouldered by the issuer. This makes them an innovative instrument, used to earmark investments in projects with a direct environmental or social benefit rather than simply on the basis of the issuer's sustainable development policy. With financing being sought for the ecological transition, green and social bonds are promising instruments, sketching out at global level the shape of tools adapted to the financing of a green economy. On the strength of these advantages, the interest of responsible investors - the main target of green and social bond issuers - is growing fast. Judging by issuer press releases and the most commonly used currencies, the main subscribers today are US investors, among them CalSTRS and fund managers like Calvert Investment Management and Trillium Asset Management. European asset owners are also starting to focus on green and social bonds. A Novethic survey shows that 13% of them have already subscribed to such an issue or plan to do so. The present study

  7. Development of HIP bonding procedure and mechanical properties of HIP bonded joints for reduced activation ferritic steel F-82H

    International Nuclear Information System (INIS)

    Oda, Masahiro; Kurasawa, Toshimasa; Kuroda, Toshimasa; Hatano, Toshihisa; Takatsu, Hideyuki

    1997-03-01

    Structural materials of blanket components in fusion DEMO reactors will receive a neutron wall load more than 3-5MW/m 2 as well as exposed by surface heat flux more than 0.5MW/m 2 . A reduced activation ferritic steel F-82H has been developed by JAERI in collaboration with NKK from viewpoints of resistance for high temperature and neutron loads and lower radioactivity. This study intends to obtain basic performance of F-82H to establish the fabrication procedure of the first wall and blanket box by using Hot Isostatic Pressing (HIP) bonding. Before HIP bonding tests, effects of heat treatment temperature and surface roughness on mechanical properties of joints were investigated in the heat treatment tests and diffusion bonding tests, respectively. From these results, the optimum HIP bonding conditions and the post heat treatment were selected. Using these conditions, the HIP bonding tests were carried out to evaluate HIP bondability and to obtain mechanical properties of the joints. Sufficient HIP bonding performance was obtained under the temperature of 1040degC, the compressive stress of 150MPa, the holding time of 2h, and the surface roughness ∼μ m. Mechanical properties of HIP bonded joints with these conditions were similar to those of as-received base metal. An oxide formation on the surface to be bonded would need to be avoided for sufficient bonding. The bonding ratio, Charpy impact value and fatigue performance of the joints strongly depended on the HIP conditions, especially temperature, while micro-structure, Vickers hardness and tensile properties had little dependence on the HIP temperature. The surface roughness strongly affected the bonding ratio and would be required to be in the level of a few μ m. In the HIP bonding test of the welded material, the once-melted surface could be jointed by the HIP bonding under the above-mentioned procedure. (J.P.N.)

  8. Crack propagation studies and bond coat properties in thermal ...

    Indian Academy of Sciences (India)

    Unknown

    sion of Al from Co base coatings on Ni base superalloy at high temperatures with ... stabilized with 8 wt% yttria thermal barrier coating was applied over the bond ... and machined to the size shown in table 1, where h is the height, b the width ...

  9. Shear bond strength of two 2-step etch-and-rinse adhesives when bonding ceramic brackets to bovine enamel.

    Science.gov (United States)

    Godard, Marion; Deuve, Benjamin; Lopez, Isabelle; Hippolyte, Marie-Pascale; Barthélemi, Stéphane

    2017-09-01

    The present study assessed a fracture analysis and compared the shear bond strength (SBS) of two 2-step etch-and-rinse (E&R) adhesives when bonding ceramic orthodontic brackets to bovine enamel. Thirty healthy bovine mandibular incisors were selected and were equally and randomly assigned to 2 experimental groups. Ceramic brackets (FLI Signature Clear ® , RMO) were bonded onto bovine enamel using an adhesive system. In group 1 (n=15), the conventional E&R adhesive (OrthoSolo ® +Enlight ® , Ormco) was used, and in group 2 (n=15), the new E&R adhesive limited to ceramic bracket bonding (FLI ceramic adhesive ® : FLI sealant resin ® +FLI adhesive paste ® , RMO) was used. In order to obtain appropriate enamel surfaces, the vestibular surfaces of mandibular bovine incisors were flat ground. After bonding, all the samples were stored in distilled water at room temperature for 21 days and subsequently tested for SBS, using the Instron ® universal testing machine. The Adhesive Remnant Index (ARI) scores were evaluated. Failure modes were assessed using optical microscopy at magnification ×40. A statistic data analysis was performed using the Mann-Whitney U-test (Penamel/adhesive interface. A statistically significant difference was found for the ARI scores between the two groups (P=0.00996). Only two fractured brackets, which remained bonded onto the bovine enamel, were reported. Both occurred in group 1. When bonded to ceramic brackets, FLI ceramic adhesive ® (RMO) was demonstrated to be very predictable and safe for clinical application in enamel bonding, whereas the results obtained with the conventional adhesive system (OrthoSolo ® +Enlight ® , Ormco) were less reproducible and revealed slightly excessive shear bond strength values. Copyright © 2017 CEO. Published by Elsevier Masson SAS. All rights reserved.

  10. Corporate Bonds in Denmark

    DEFF Research Database (Denmark)

    Tell, Michael

    2015-01-01

    Corporate financing is the choice between capital generated by the corporation and capital from external investors. However, since the financial crisis shook the markets in 2007–2008, financing opportunities through the classical means of financing have decreased. As a result, corporations have...... to think in alternative ways such as issuing corporate bonds. A market for corporate bonds exists in countries such as Norway, Germany, France, the United Kingdom and the United States, while Denmark is still behind in this trend. Some large Danish corporations have instead used foreign corporate bonds...... markets. However, NASDAQ OMX has introduced the First North Bond Market in December 2012 and new regulatory framework came into place in 2014, which may contribute to a Danish based corporate bond market. The purpose of this article is to present the regulatory changes in Denmark in relation to corporate...

  11. Interface structure of Be/DSCu diffusion bonding

    Energy Technology Data Exchange (ETDEWEB)

    Makino, T.; Iwadachi, T. [NGK Insulators Ltd., Nagoya (Japan)

    1998-01-01

    Beryllium is used as plasma facing components of the first wall on ITER. Dispersion-Strengthened Copper (DSCu) is used as heat sink material by joining to Be because DSCu has high thermal conductivity and strength. In this study, Be/DSCu diffusion bonding tests using the interlayer of Al, Ni, Nb, Ti, Zr and Be-Cu alloy have been conducted to choose the suitable interlayer materials. As a result of the shear strength tests, Be/DSCu joints by using Be-Cu alloy interlayer showed the strength of about 200 MPa. Diffusion bonding tests using Be-Cu alloy interlayer or no interlayer (direct bonding) at the range of temperature from 600degC to 850degC have been conducted to identify the effect of bonding temperature and time on interface formation and strength. The thickness of diffusion layer was proportional to a square root of bonding time by diffusion controlled process. The shear strength is controlled by the formation of intermetallic layer at Be side. (author)

  12. Composite Laser Ceramics by Advanced Bonding Technology

    Science.gov (United States)

    Kamimura, Tomosumi; Honda, Sawao

    2018-01-01

    Composites obtained by bonding materials with the same crystal structure and different chemical compositions can create new functions that do not exist in conventional concepts. We have succeeded in bonding polycrystalline YAG and Nd:YAG ceramics without any interstices at the bonding interface, and the bonding state of this composite was at the atomic level, similar to the grain boundary structure in ceramics. The mechanical strength of the bonded composite reached 278 MPa, which was not less than the strength of each host material (269 and 255 MPa). Thermal conductivity of the composite was 12.3 W/mK (theoretical value) which is intermediate between the thermal conductivities of YAG and Nd:YAG (14.1 and 10.2 W/mK, respectively). Light scattering cannot be detected at the bonding interface of the ceramic composite by laser tomography. Since the scattering coefficients of the monolithic material and the composite material formed by bonding up to 15 layers of the same materials were both 0.10%/cm, there was no occurrence of light scattering due to the bonding. In addition, it was not detected that the optical distortion and non-uniformity of the refractive index variation were caused by the bonding. An excitation light source (LD = 808 nm) was collimated to 200 μm and irradiated into a commercial 1% Nd:YAG single crystal, but fracture damage occurred at a low damage threshold of 80 kW/cm2. On the other hand, the same test was conducted on the bonded interface of 1% Nd:YAG-YAG composite ceramics fabricated in this study, but it was not damaged until the excitation density reached 127 kW/cm2. 0.6% Nd:YAG-YAG composite ceramics showed high damage resistance (up to 223 kW/cm2). It was concluded that composites formed by bonding polycrystalline ceramics are ideal in terms of thermo-mechanical and optical properties. PMID:29425152

  13. Composite Laser Ceramics by Advanced Bonding Technology.

    Science.gov (United States)

    Ikesue, Akio; Aung, Yan Lin; Kamimura, Tomosumi; Honda, Sawao; Iwamoto, Yuji

    2018-02-09

    Composites obtained by bonding materials with the same crystal structure and different chemical compositions can create new functions that do not exist in conventional concepts. We have succeeded in bonding polycrystalline YAG and Nd:YAG ceramics without any interstices at the bonding interface, and the bonding state of this composite was at the atomic level, similar to the grain boundary structure in ceramics. The mechanical strength of the bonded composite reached 278 MPa, which was not less than the strength of each host material (269 and 255 MPa). Thermal conductivity of the composite was 12.3 W/mK (theoretical value) which is intermediate between the thermal conductivities of YAG and Nd:YAG (14.1 and 10.2 W/mK, respectively). Light scattering cannot be detected at the bonding interface of the ceramic composite by laser tomography. Since the scattering coefficients of the monolithic material and the composite material formed by bonding up to 15 layers of the same materials were both 0.10%/cm, there was no occurrence of light scattering due to the bonding. In addition, it was not detected that the optical distortion and non-uniformity of the refractive index variation were caused by the bonding. An excitation light source (LD = 808 nm) was collimated to 200 μm and irradiated into a commercial 1% Nd:YAG single crystal, but fracture damage occurred at a low damage threshold of 80 kW/cm². On the other hand, the same test was conducted on the bonded interface of 1% Nd:YAG-YAG composite ceramics fabricated in this study, but it was not damaged until the excitation density reached 127 kW/cm². 0.6% Nd:YAG-YAG composite ceramics showed high damage resistance (up to 223 kW/cm²). It was concluded that composites formed by bonding polycrystalline ceramics are ideal in terms of thermo-mechanical and optical properties.

  14. 77 FR 29472 - Surety Companies Acceptable on Federal Bonds-Termination: Atlantic Bonding Company, Inc.

    Science.gov (United States)

    2012-05-17

    ... be accepted from this company, and bonds that are continuous in nature should not be renewed. The... DEPARTMENT OF THE TREASURY Fiscal Service Surety Companies Acceptable on Federal Bonds--Termination: Atlantic Bonding Company, Inc. AGENCY: Financial Management Service, Fiscal Service, Department...

  15. Diffusion bonding of IN 718 to VM 350 grade maraging steel

    Science.gov (United States)

    Crosby, S. R.; Biederman, R. R.; Reynolds, C. C.

    1972-01-01

    Diffusion bonding studies have been conducted on IN 718, VM 350 and the dissimilar alloy couple, IN 718 to maraging steel. The experimental processing parameters critical to obtaining consistently good diffusion bonds between IN 718 and VM 350 were determined. Interrelationships between temperature, pressure and surface preparation were explored for short bending intervals under vacuum conditions. Successful joining was achieved for a range of bonding cycle temperatures, pressures and surface preparations. The strength of the weaker parent material was used as a criterion for a successful tensile test of the heat treated bond. Studies of VM-350/VM-350 couples in the as-bonded condition showed a greater yielding and failure outside the bond region.

  16. A Comparison of the Use of Bony Anatomy and Internal Markers for Offline Verification and an Evaluation of the Potential Benefit of Online and Offline Verification Protocols for Prostate Radiotherapy

    International Nuclear Information System (INIS)

    McNair, Helen A.; Hansen, Vibeke N.; Parker, Christopher; Evans, Phil M.; Norman, Andrew; Miles, Elizabeth; Harris, Emma J.; Del-Acroix, Louise; Smith, Elizabeth; Keane, Richard; Khoo, Vincent S.; Thompson, Alan C.; Dearnaley, David P.

    2008-01-01

    Purpose: To evaluate the utility of intraprostatic markers in the treatment verification of prostate cancer radiotherapy. Specific aims were: to compare the effectiveness of offline correction protocols, either using gold markers or bony anatomy; to estimate the potential benefit of online correction protocol's using gold markers; to determine the presence and effect of intrafraction motion. Methods and Materials: Thirty patients with three gold markers inserted had pretreatment and posttreatment images acquired and were treated using an offline correction protocol and gold markers. Retrospectively, an offline protocol was applied using bony anatomy and an online protocol using gold markers. Results: The systematic errors were reduced from 1.3, 1.9, and 2.5 mm to 1.1, 1.1, and 1.5 mm in the right-left (RL), superoinferior (SI), and anteroposterior (AP) directions, respectively, using the offline correction protocol and gold markers instead of bony anatomy. The subsequent decrease in margins was 1.7, 3.3, and 4 mm in the RL, SI, and AP directions, respectively. An offline correction protocol combined with an online correction protocol in the first four fractions reduced random errors further to 0.9, 1.1, and 1.0 mm in the RL, SI, and AP directions, respectively. A daily online protocol reduced all errors to <1 mm. Intrafraction motion had greater impact on the effectiveness of the online protocol than the offline protocols. Conclusions: An offline protocol using gold markers is effective in reducing the systematic error. The value of online protocols is reduced by intrafraction motion

  17. Musculo-nasomucosal unit with complete lateral bony freeing and medial rotation for ideal C-shape restoration and retropositioning of the levator veli palatini.

    Science.gov (United States)

    El-Shazly, Mohamed

    2012-11-01

    No definitive procedure for cleft repair has been identified yet as the gold standard. Accordingly, this work tried to appraise the hypothesis that if the bony detachment and full retropositioning of the levator veli palatini muscle can ideally present an anatomical C-shape muscular sling restoration and if this is accompanied with pushback palatoplasty, would this present a better result in terms of tissue fistulation and phonetic impairment? A series of 74 different degrees of palatal clefts were operated by pushback palatoplasty combined with a modified approach of the levator vili palatini. This muscle was dissected only from the oral mucosa while kept attached to the nasal one as a musculo-nasomucosal unit. This unit was completely detached from the bony margin of the hard palate and then medially rotated and retropositioned in a typical C-shape mobile sling. Evaluations included suture line assessment and fistula development, and following the child's need for speech therapy. There were no intraoperative complications. Definite anterior fistulae with nasal air and foot leakage were observed in 2 cases. Four cases had postoperative velopharyngeal incompetence with a need for speech therapy. Tension-free closure, lower risk of fistula, good restoration of velopharyngeal functions, ability to be performed on all cleft types, ability to provide a good intraoperative exposure, and being a single stage seem to be the most important advantages of this unpublished technique.

  18. Comparison of shear bond strength of self-etch and self-adhesive cements bonded to lithium disilicate, enamel and dentin.

    Science.gov (United States)

    Naranjo, Jennifer; Ali, Mohsin; Belles, Donald

    2015-11-01

    Comparison of shear bond strength of self-etch and self-adhesive cements bonded to lithium disilicate, enamel and dentin. With several self-adhesive resin cements currently available, there is confusion about which product and technique is optimal for bonding ceramic restorations to teeth. The objective of this study was to compare the shear bond strength of lithium disilicate cemented to enamel and dentin using 5 adhesive cements. 100 lithium disilicate rods were pretreated with 5% hydrofluoric acid, silane, and cemented to 50 enamel and 50 dentin surfaces using five test cements: Variolink II (etch-and-rinse) control group, Clearfil Esthetic (two step self-etch), RelyX Unicem, SpeedCEM, and BifixSE (self-adhesive). All specimens were stored (37 degrees C, 100% humidity) for 24 hours before testing their shear bond strength using a universal testing machine (Instron). Debonded surfaces were observed under a low-power microscope to assess the location and type of failure. The highest bond strength for both enamel and dentin were recorded for Variolink II, 15.1MPa and 20.4MPa respectively, and the lowest were recorded for BifixSE, 0.6MPa and 0.9MPa respectively. Generally, higher bond strengths were found for dentin (7.4MPa) than enamel (5.3MPa). Tukey's post hoc test showed no significant difference between Clearfil Esthetic and SpeedCem (p = 0.059), Unicem and SpeedCem (p = 0.88), and Unicem and BifixSE (p = 0.092). All cements bonded better to lithium disilicate than to enamel or dentin, as all bond failures occurred at the tooth/adhesive interface except for Variolink II. Bond strengths recorded for self-adhesive cements were very low compared to the control "etch and rinse" and self-etch systems. Further improvements are apparently needed in self-adhesive cements for them to replace multistep adhesive systems. The use of conventional etch and rinse cements such as Veriolink II should be preferred for cementing all ceramic restorations over self-adhesive cements

  19. Comparative study of the dental substrate used in shear bond strength tests

    Directory of Open Access Journals (Sweden)

    Lopes Murilo Baena

    2003-01-01

    Full Text Available The purpose of this study was to compare shear bond strength values obtained in human enamel and dentin with the values obtained in bovine teeth using two adhesive systems with different actions. Forty human tooth half-crowns and forty bovine tooth crowns were flattened to a minimum plain area of 5 mm in diameter. The samples were divided in four groups of 20 specimens each: 1 human enamel; 2 bovine enamel; 3 human dentin; 4 bovine dentin. The samples of each group were divided in 2 subgroups of 10 samples each, according to the adhesive system used: 1 Scotchbond Multi-Purpose (SBMP; and 2 Clearfil Liner Bond 2V (CLB2V applied according to the manufacturer's recommendations. Afterwards, restorations of Z100 composite with cylindrical shape (4 mm diameter x 5 mm height were made using a metallic mold to submit the samples to shear bond testing on an Instron universal testing machine, at a crosshead speed of 0.5 mm/min. The data were submitted to ANOVA and Tukey's test (5%. In enamel, there was no statistical difference between bovine and human teeth for SBMP (7.36 MPa, human; 8.24 MPa, bovine, nor for CLB2V (10.01 MPa, human; 7.95, bovine. In dentin, SBMP showed a statistically lower mean on human dentin (7.01 MPa than on bovine dentin (11.74 MPa. For CLB2V, there was no statistical difference between human (7.43 MPa and bovine (9.27 MPa substrates.

  20. Macroeconomic determinants of conditional stock-bond correlation ...

    African Journals Online (AJOL)

    The study focuses on the dependence of stock-bond returns correlation on inflation and interest rate, and attempts to explain conditional stock-bond correlation using the argument that these variables' effects change based on levels of their volatilities as suggested by rational present value asset pricing theory, rather than ...