WorldWideScience

Sample records for bone-patellar tendon-bone graft

  1. Press-fit Femoral Fixation in ACL Reconstruction using Bone-Patellar Tendon-Bone Graft

    Directory of Open Access Journals (Sweden)

    Kaseb Mohammad Hasan

    2009-05-01

    Full Text Available Bone-patellar tendon auto graft is probably the most widely used graft for ACL reconstruction. Several methods for graft fixation have been described. To avoid intra-articular hardware we adopt biological fixation with a femoral trapezoidal press-fit fixation. A prospective study was performed on 30 consecutive active people who underwent ACL reconstruction with this technique by two surgeons between september2004 and march2007 (mean follow-up 15.2 months. Results were evaluated by an independent examiner using radiography, subjective and objective evaluation. Assessment using the IKDC knee scoring revealed 92% of the patients with a normal or nearly normal knee joint. Lysholm's score was 63.6(40- 86 preoperatively and 91.88(73-100 at the latest follow up (P < 0.005. No patient complained of instability at latest follow up. The quadriceps muscle showed mild atrophy at 3 and 6 months and at final follow-up. Five Patients complained of anterior knee pain and had a positive kneeling test. We found no graft displacement on follow up radiographs. All cases showed radiological evidence of graft osteointegration at last follow up. Our results show that press-fit fixation of trapezoidal bone graft in femoral tunnel is a simple, reliable, and cost-effective alternative for ACL recon-struction using bone-patellar tendon-bone graft.

  2. Assessment of rotatory instability after anterior cruciate ligament reconstruction with a bone-patellar tendon-bone graft

    International Nuclear Information System (INIS)

    Tashiro, Yasutaka; Okazaki, Ken; Miura, Hiromasa

    2010-01-01

    Anatomically oriented anterior cruciate ligament (ACL) reconstruction has been advocated recently, but its effect on rotatory instability remains to be cleared objectively. The purpose of this study was to quantitatively evaluate rotatory instability in ACL reconstructed knees with a bone-patellar tendon-bone (BTB) graft using an open MRI system. Eighteen subjects underwent arthroscopic ACL reconstruction with a BTB graft. The tibial tunnel was placed in the center of the ACL footprint. The femoral tunnel was drilled transtibially at the 10:00 to 10:30-o'clock position for the right knees. Subjects were examined using a Slocum anterolateral rotatory instability test in open MRI. Anterior tibial translation was measured at the medial and lateral compartments by evaluating sagittal images. Anterior knee stability was evaluated using the KT-2000 arthrometer. The clinical knee function was assessed with the Lysholm and Tegner scoring scales before and after the surgery. Side-to-side differences of anterolateral tibial translation was 0.1 mm. Side-to-side difference on KT-2000 arthrometer measurement was 1.8 mm. The Lysholm score improved to 96 and the latest Tegner score reached substantially the preinjury level. ACL reconstruction with a BTB graft was successful in restoring rotatory stability as well as anterior stability and knee function. (author)

  3. Clinical evaluation of bone- patellar tendon- bone grafts for anterior cruciate ligament injury

    International Nuclear Information System (INIS)

    Nakamura, Yasuhiro

    2011-01-01

    One thousand and thirty-eight cases of Anterior Cruciate Ligament (ACL) rupture were treated between January 2002 and November 2010. Eight hundred sixty-six cases (83.9%) were observed for at least six months. All cases were reconstructed with a bone to tendon to bone (BTB) graft from the patella. Much effort was made to return the patient to a competitive sports activity level within one year. The age at suffering from the initial injury ranged from 9 to 74 years old with a mean of 24.7 years old. There were 493 female (50.7%) and 427 male (49.3%) cases. The injured side was right in 408 cases and left in 458 cases. The mean postoperative observation period was 449.2 days. The number of patients who felt 80% or more certain that they could return to competitive sports activities was 538 (61.9%). From the MRI findings, continuity of the reconstructed graft was observed in 793 cases (98.5%). Arthroscopy after reconstruction was performed in 775 cases (89.5%). The reconstructed ACL was observed to be covered with an adequate synovium in 629 cases (81.2%). The medial meniscus and lateral meniscus showed no changes in 657 cases (84.8%) and 666 cases (85.9%) respectively. Reconstructions performed less than two weeks after injury showed no significant differences in terms of Range Of Motion (ROM), arthroscopic findings, or the number of patients who could return to competitive sports activities. Statistically significantly more patients who underwent their reconstruction at an age over forty experienced a loss motion of five degree in extension or ten degree in flexion and resumed a lower level of sports activities. Patients who underwent the reconstruction could return to exercises for muscle strengthening and ROMs within 2 weeks. Patients over forty years old who underwent their reconstruction could prevent their menisci from fraying, tearing, or undergoing osteoarthritic changes. (author)

  4. Anterior Cruciate Ligament Reconstruction using Bone Patellar Tendon Bone autograft in ACL deficient Knee

    Directory of Open Access Journals (Sweden)

    Navin Kumar Karn

    2015-12-01

    Full Text Available Background & Objectives: Injury to Anterior Cruciate Ligament (ACL reconstruction has increased because of increased interest in sports. There are various grafts used for reconstruction of ACL, for example, Bone Patellar Tendon Bone, Hamstring etc. The study was conducted to evaluate the results of Bone Patellar Tendon Bone graft used for reconstruction of Anterior Cruciate Ligament.Materials & Methods: 40 patients with chronic ACL deficient knee presenting to Neuro Hospital from July 2011 to June 2013 were included in the study. The patients with intraarticular fracture of knee, severe OA knee, local active or suspected infection and systemic disease that might influence the study results were excluded from the study. Bone patellar tendon bone graft was harvested from ipsilateral knee in all the cases. The patient was followed till 2 year with specified programme of rehabilitation. The pain was assessed using VAS and the function of the knee was assessed using Modified WOMAC knee index.Results: The long term satisfactory results in terms of functional stability, symptom relief and return to preinjury level of activity was seen in 32 cases (80%. Two knees got infected out of which one required arthroscopic debridement. Mean visual analogue scale was 8 and modified WOMAC knee score was 3 at 2 year follow up.Conclusion: Bone patellar tendon bone graft is useful in high demand patients and cost effective option with high patient satisfaction rate for reconstruction of ACL.JCMS Nepal. 2015;11(3:12-15.

  5. FUNCTIONAL OUTCOME OF ACCELERATED REHABILITATION IN ARTHROSCOPIC ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION WITH BONE PATELLAR TENDON BONE GRAFT A PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Hiranyakumar

    2016-03-01

    Full Text Available INTRODUCTION An ideal rehabilitation program post anterior cruciate ligament reconstruction enables an individual to return to pre injury levels at a faster rate with minimal to no risk of reinjury to the graft. Rehabilitation protocols have changed considerably over time in the past. It has become “aggressive”, meaning an intensive rehabilitation which includes greater variety of exercises and sports related training. AIM OF THE STUDY The aim of our study is to assess the outcome of accelerated rehabilitation post anterior cruciate ligament (ACL reconstruction. METHODOLOGY 106 patients were operated by a single surgeon underwent arthroscopic anterior cruciate ligament reconstruction using bone patella tendon bone graft and partial meniscectomy for associated meniscal tear. Patients were put on an accelerated rehabilitation protocol designed in our institute on first post-operative day, under the guidance of a physical therapist in consultation with the operated surgeon. Patients were followed up at 3 weeks, 6 months and 9 months, post onset of rehabilitation, patients were assessed using KT1000 Arthrometer and Lysholm knee scoring system. RESULTS Out of 106 patients, who were selected, 96(91% were males and 10(9% were females. The mean pre-operative Lysholm score was 55.09. Post operatively, while on accelerated rehabilitation program the Lysholm scores were 69.73 at 3 weeks, 89.13 at 6 months and 89.19 at 9 months. In our pre-operative evaluation mean KT 1000 arthrometer score was 10.53 and post-operative at six months was 3.49. At nine months 105 patients had excellent results whereas 1 patient had good result. CONCLUSION Accelerated rehabilitation protocol enables the patient to functionally recover faster to pre injury levels. A rehabilitation protocol for 6 months is sufficient in enabling a patient to get back to pre-injury levels. Functional outcome is the same with or without associated meniscal injuries.

  6. ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION: A COMPARISON BETWEEN BONE PATELLAR TENDON BONE GRAFT AND LIPSCOMB PROCEDURE - A FOLLOWUP STUDY OF 7 YEARS

    Directory of Open Access Journals (Sweden)

    Vijayamohan S

    2016-07-01

    Full Text Available BACKGROUND Anterior Cruciate Ligament injury has become more common and the demand by the patients to return to pre-injury level of activity has made reconstruction of the ligament very crucial. Though there are various techniques in reconstructing the anterior cruciate ligament, in this study, we compare two most commonly used techniques to see whether there is any significant difference in the outcome. METHODS Study included 25 patients in the age group of 19-36 years, of which 23 were males. The patients were divided randomly into 2 groups, and 15 patients underwent Anterior Cruciate Ligament reconstruction using Bone Patellar Tendon Bone Graft and 10 patients had Hamstring graft. RESULTS Patients were followed up at regular intervals monthly for the first six months and then at three monthly intervals. Patients were assessed using Knee Scoring Scale of Lysholm and Gillquist and International Knee Documentation Committee (IKDC scoring system. In addition, activity level, harvest site pain, thigh atrophy, kneeling pain and hamstring pain were assessed. All patients were followed up for a minimum period of 2 years. 20% of both groups were able to return to strenuous activity level, and 67% of Patellar tendon group and 50% of the Hamstring tendon group were able to return to moderate level of activity. 55% of patients in the patellar tendon group and 20% of patients in the hamstring tendon group had donor site pain in the first 6 months. 73% of patients in the hamstring group had at least 10 mm of thigh wasting. Pain on kneeling was seen only in the patellar tendon group (35% while hamstring pain was found only in the hamstring group (20%. CONCLUSIONS Patients in the patellar tendon group had increased anterior stability and were able to return to strenuous occupation. The difference in thigh atrophy between the two groups was not significant. The hamstring group had lower graft harvest site morbidity. Lachman test was the single most accurate

  7. COMPARATIVE STUDY OF CLINICAL OUTCOME OF ARTHROSCOPIC ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION BONE PATELLAR TENDON BONE GRAFT V/S HAMSTRING GRAFT

    Directory of Open Access Journals (Sweden)

    Priyank

    2015-08-01

    fulfilling the predetermined inclusion and exclusion criteria were included in the study. STATISTICAL METHODS : Intergroup comparison was analysed by K - Independent sample t test. Intragroup comparison was analysed by Paired t - test. RESULTS : Patients were divided into two groups and treated with using Bone - patellar tendon - bone graft and Hamstring graft respectively. Mean age group of patients was 29.16 yrs. (range 16 - 51yrs and 30.88 yrs. (range 19 - 48yrs in group A and B respectively we found the incidence of ACL injury in 15 - 44 years age group to be greater than twice the general population. A mean delay in surgery of 4.66 months (range 2 - 12 months since the time of injury in group A and 4.46 months (range 2 - 7 months in group B was observed. Subjective IKDC evaluation was done at the end of 12 months. Ther e was no difference in both the groups in the terms of effusion, passive motion, knee compartment findings, ligament examination, X - ray findings. Functional test and IKDC grade of both the groups showed statistically very highly significant improvement. Ho wever, there was statistically very high Harvest site pathology in group A. CONCLUSION : We found that there is statistically no significant difference in the overall clinical outcome between hamstring autograft with transfix and bone - patellar tendon bone autograft with interference screw except that the patellar tendon group had a greater tendency of having donor site morbidity compared to the hamstring tendon group.

  8. Early integration of a bone plug in the femoral tunnel in rectangular tunnel ACL reconstruction with a bone-patellar tendon-bone graft: a prospective computed tomography analysis.

    Science.gov (United States)

    Suzuki, Tomoyuki; Shino, Konsei; Nakagawa, Shigeto; Nakata, Ken; Iwahashi, Takehiko; Kinugasa, Kazutaka; Otsubo, Hidenori; Yamashita, Toshihiko

    2011-12-01

    The purpose of this prospective study was to evaluate how early the bone plug was integrated into the rectangular femoral tunnel after anatomical ACL reconstruction using a bone-patellar tendon-bone (BTB) graft via a rectangular tunnel (RT BTB ACL-R). Twenty consecutive patients who had undergone the reconstruction procedure were evaluated by CT scans at 4 and 8 weeks postoperatively. In each scan, 30 slices for multiplanar reconstruction were collected parallel to the long axis of the parallelepiped femoral tunnel and perpendicular to the tendinous plane of the bone plug. Each slice was classified as "complete," indicating no visible gap between the plug and the tunnel wall or trabecular continuity or "incomplete," showing a visible gap. Bone plug-tunnel integration was evaluated as "excellent," "good," "fair," or "poor" for >20, 11-20, 5-10, and values at the anterior interface between the bone plug and the tunnel wall were also measured on both scans. The mean changes in CT value at 8 weeks were significantly lower than those at 4 weeks. This study shows that bone plug-femoral tunnel integration was almost complete by 8 weeks after surgery using RT BTB ACL-R.

  9. Anterior-Posterior Instability of the Knee Following ACL Reconstruction with Bone-Patellar Tendon-Bone Ligament in Comparison with Four-Strand Hamstrings Autograft

    Directory of Open Access Journals (Sweden)

    A. G. Angoules

    2013-01-01

    Full Text Available Purpose. To evaluate anterior-posterior knee laxity using two different autografts. Material-Methods. 40 patients, (34 males and 6 women, 17–54 years old (mean: 31, were included in the present study. Group A (4SHS = 20 underwent reconstruction using four-strand hamstrings, and group B (BPBT = 20 underwent reconstruction using bone-patellar tendon-bone autograft. Using the KT-1000 arthrometer, knee instability was calculated in both knees of all patients preoperatively and 3, 6, and 12 months after surgery at the ACL-operated knee. The contralateral healthy knee was used as an internal control group. Results. Anterior-posterior instability using the KT1000 Arthrometer was found to be increased after ACL insufficiency. The recorded laxity improved after arthroscopic ACL reconstruction in both groups. However, statistically significant greater values were detected in the bone-patellar tendon-bone group, which revealed reduction of anteroposterior stability values to an extent, where no statistical significance with the normal values even after 3 months after surgery was observed. Conclusions. Anterior-Posterior instability of the knee improved significantly after arthroscopic ACL reconstruction. The bone-patellar tendon-bone graft provided an obvious greater stability.

  10. Patella fracture during rehabilitation after bone-patellar tendon-bone anterior cruciate ligament reconstruction: 2 case reports.

    Science.gov (United States)

    Piva, Sara R; Childs, John D; Klucinec, Brian M; Irrgang, James J; Almeida, Gustavo J M; Fitzgerald, G Kelley

    2009-04-01

    Case report. Patellar fracture is a rare but significant complication following anterior cruciate ligament (ACL) reconstruction when using a bone-patellar tendon-bone (BPTB) autograft. The purpose of these case reports is to describe 2 cases in which patellar fracture occurred during rehabilitation after ACL reconstruction using a BPTB. Both patients were 23-year-old males referred for rehabilitation after ACL reconstruction using a BPTB autograft. They were both progressing satisfactorily in rehabilitation until sustaining a fracture of the patella. One fracture occurred during the performance of the eccentric phase of a knee extension exercise during the sixth week of rehabilitation (7 weeks postsurgery), whereas the other fracture occurred during testing of the patient is quadriceps maximum voluntary isometric contraction in the ninth week of rehabilitation (10 weeks postsurgery). Both patients were subsequently treated with open reduction and internal fixation of the patella. During rehabilitation following ACL reconstruction using BPTB autograft, clinicians should consider the need to balance the sometimes-competing goals of improving quadriceps strength while providing protection to the healing graft, minimization of patellofemoral pain, and protection of the patellar donor site.

  11. Reconstruction of the anterior cruciate ligament : a clinical comparison of bone-patellar tendon-bone single bundle versus semitendinosus and gracilis double bundle technique

    NARCIS (Netherlands)

    Sadoghi, Patrick; Mueller, Peter E.; Jansson, Volkmar; van Griensven, Martin; Kroepfl, Albert; Fischmeister, Martin F.

    The study hypothesis was that the outcome of semitendinosus gracilis double bundle (STG-DB) anterior cruciate ligament (ACL) reconstruction is advantageous in terms of clinical results and restoration of anterior-posterior and rotational laxity in comparison to bone-patellar tendon-bone

  12. Increased Risk of Revision After Anterior Cruciate Ligament Reconstruction With Bone-Patellar Tendon-Bone Allografts Compared With Autografts.

    Science.gov (United States)

    Maletis, Gregory B; Chen, Jason; Inacio, Maria C S; Love, Rebecca M; Funahashi, Tadashi T

    2017-05-01

    The use of allograft tissue for anterior cruciate ligament reconstruction (ACLR) remains controversial. To compare the risk of aseptic revision between bone-patellar tendon-bone (BPTB) autografts and BPTB allografts. Cohort study; Level of evidence, 2. A retrospective cohort study of prospectively collected data was conducted using the Kaiser Permanente ACLR Registry. A cohort of patients who underwent primary unilateral ACLR with BPTB autografts and BPTB allografts was identified. Aseptic revision was the endpoint. The type of graft and allograft processing method (nonprocessed, <1.8-Mrad, and ≥1.8-Mrad irradiation) were the exposures of interest evaluated. Age (≤21 and ≥22 years) was evaluated as an effect modifier. Analyses were adjusted for age, sex, and race. Kaplan-Meier curves and Cox proportional hazards models were employed. Hazard ratios (HRs) and 95% CIs are provided. The BPTB cohort consisted of 5586 patients: 3783 (67.7%) were male, 2359 (42.2%) were white, 1029 (18.4%) had allografts (nonprocessed: 155; <1.8 Mrad: 525; ≥1.8 Mrad: 288), and 4557 (81.6%) had autografts. The median age was 34.9 years (interquartile range [IQR], 25.4-44.0) for allograft cases and 22.0 years (IQR, 17.6-30.0) for autograft cases. The estimated cumulative revision rate at 2 years was 4.1% (95% CI, 2.9%-5.9%) for allografts and 1.7% (95% CI, 1.3%-2.2%) for autografts. BPTB allografts had a significantly higher adjusted risk of revision than BPTB autografts (HR, 4.54; 95% CI, 3.03-6.79; P < .001). This higher risk of revision was consistent with all allograft processing methods when compared with autografts and was also consistently higher in patients with allografts regardless of age. When BPTB allograft tissue was used for ACLR, an overall 4.54 times adjusted higher risk of revision was observed compared with surgery performed with a BPTB autograft. Whether the tissue was irradiated with either high- or low-dose radiation, chemically processed, or not processed at

  13. Double-layer versus single-layer bone-patellar tendon-bone anterior cruciate ligament reconstruction: a prospective randomized study with 3-year follow-up.

    Science.gov (United States)

    Mei, Xiaoliang; Zhang, Zhenxiang; Yang, Jingwen

    2016-12-01

    To evaluate the clinical results of a randomized controlled trial of single-layer versus double-layer bone-patellar tendon-bone (BPTB) anterior cruciate ligament (ACL) reconstruction. Fifty-eight subjects who underwent primary ACL reconstruction with a BPTB allograft were prospectively randomized into two groups: single-layer reconstruction (n = 31) and double-layer reconstruction (n = 27). The following evaluation methods were used: clinical examination, KT-1000 arthrometer measurement, muscle strength, Tegner activity score, Lysholm score, subjective rating scale regarding patient satisfaction and sports performance level, graft retear, contralateral ACL tear, and additional meniscus surgery. Forty-eight subjects (24 in single-layer group and 24 in double-layer group) who were followed up for 3 years were evaluated. Preoperatively, there were no differences between the groups. At 3-year follow-up, the Lachman and pivot-shift test results were better in the double-layer group (P = 0.019 and P reconstruction, double-layer BPTB reconstruction was significantly better than single-layer reconstruction regarding anterior and rotational stability at 3-year follow-up. The results of KT measurements and the Lachman and pivot-shift tests were significantly better in the double-layer group, whereas there was no difference in the anterior drawer test results. The Tegner score was also better in the double-layer group; however, there were no differences in the other subjective findings.

  14. Pullout strength of bone-patellar tendon-bone allograft bone plugs: a comparison of cadaver tibia and rigid polyurethane foam.

    Science.gov (United States)

    Barber, F Alan

    2013-09-01

    To compare the load-to-failure pullout strength of bone-patellar tendon-bone (BPTB) allografts in human cadaver tibias and rigid polyurethane foam blocks. Twenty BPTB allografts were trimmed creating 25 mm × 10 mm × 10 mm tibial plugs. Ten-millimeter tunnels were drilled in 10 human cadaver tibias and 10 rigid polyurethane foam blocks. The BPTB anterior cruciate ligament allografts were inserted into these tunnels and secured with metal interference screws, with placement of 10 of each type in each material. After preloading (10 N), cyclic loading (500 cycles, 10 to 150 N at 200 mm/min) and load-to-failure testing (200 mm/min) were performed. The endpoints were ultimate failure load, cyclic loading elongation, and failure mode. No difference in ultimate failure load existed between grafts inserted into rigid polyurethane foam blocks (705 N) and those in cadaver tibias (669 N) (P = .69). The mean rigid polyurethane foam block elongation (0.211 mm) was less than that in tibial bone (0.470 mm) (P = .038), with a smaller standard deviation (0.07 mm for foam) than tibial bone (0.34 mm). All BPTB grafts successfully completed 500 cycles. The rigid polyurethane foam block showed less variation in test results than human cadaver tibias. Rigid polyurethane foam blocks provide an acceptable substitute for human cadaver bone tibia for biomechanical testing of BPTB allografts and offer near-equivalent results. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  15. Isokinetic quadriceps and hamstring muscle strength and knee function 5 years after anterior cruciate ligament reconstruction: comparison between bone-patellar tendon-bone and hamstring tendon autografts.

    Science.gov (United States)

    Lautamies, Riitta; Harilainen, Arsi; Kettunen, Jyrki; Sandelin, Jerker; Kujala, Urho M

    2008-11-01

    Existing clinical studies have not proven which graft is to be preferred in anterior cruciate ligament (ACL) reconstruction. In recent years, bone-patellar tendon-bone and hamstring tendons have been the most frequently used graft types. Muscle strength deficit is one of the consequences after ACL reconstruction. The aim of this study was to evaluate possible differences in hamstring and quadriceps muscle strength and knee function 5 years after ACL reconstruction between the BPTB and the STG groups. The study group consisted of 288 patients (132 women, 156 men) with a unilateral ACL rupture who had received a BPTB (175 patients) or STG (113 patients) ACL reconstruction. Lower extremity concentric isokinetic peak extension and flexion torques were assessed at the angular velocities of 60 degrees /s and 180 degrees /s. The International Knee Documentation Committee (IKDC), the Tegner activity level, the Lysholm knee and the Kujala patellofemoral scores were also collected. Isokinetic quadriceps peak torque (percentage of the contralateral side) was 3.9% higher in the STG group than in the BPTB group at the velocity of 60 degrees /s and 3.2% higher at the velocity of 180 degrees /s and the isokinetic hamstring peak torque 2% higher in the BPTB group than in the STG group at the velocity of 60 degrees /s and 2.5% higher at the velocity of 180 degrees /s. In both groups the subjects had weaker quadriceps and hamstring muscle strength in the injured extremity compared with the uninjured one. In the single-leg hop test (according to the IKDC recommendations) there was a statistically significant difference (P = 0.040) between the groups. In the STG group, 68% of the patients had the single-leg hop ratio (injured vs. uninjured extremity) > or =90%, 31% of the patients 75-89% and 1% of the patients <75%, while in the BPTB group the corresponding percentages were 72, 21 and 7%. However, no statistically significant differences in clinical outcome were found between the

  16. Proximal Tibia Fracture After Anterior Cruciate Ligament Reconstruction Using Bone-Patellar Tendon-Bone Autograft: A Case Report

    OpenAIRE

    Voos, James E.; Drakos, Mark C.; Lorich, Dean G.; Fealy, Stephen

    2007-01-01

    The optimal operative management of anterior cruciate ligament (ACL) injury continues to be debated. Many complications can occur, but fracture is often not routinely discussed. We present a complex intra-articular tibia fracture in a patient who had an autologous, ipsilateral bone-patellar-bone ACL reconstruction. While still advocating early, aggressive physical therapy, this case reminds us of the inherent susceptibility to injury in the immediate post-operative period.

  17. Arthroscopically assisted anterior cruciate ligament reconstruction with bone-patellar tendon-bone autograft without wound drainage: short- to middle-term outcome

    Directory of Open Access Journals (Sweden)

    Dariusz Witoński

    2016-05-01

    Full Text Available Introduction : Several studies have suggested that anterior cruciate ligament reconstruction (ACLR without wound drainage has no impact on long-term follow-up. Aim: To investigate a prospective patient series as measured by the patient-administered disease-specific questionnaire Knee injury and Osteoarthritis Outcome Score (KOOS. Material and methods : The study included 101 consecutive patients (71 men and 30 women with a mean age of 30 years (SD 10, range: 15–62 years, who had undergone primary single incision arthroscopic bone-patellar tendon-bone autograft (BPTB ACLR without wound drainage. All patients completed KOOS questionnaires, preoperatively and at a mean follow-up of 1.4 years (range: 0.4–3.4. Satisfactory clinical outcome (function recovery – FR was defined as the lower threshold for the 95% CI of 18–34-year old males and corresponded to a KOOS score > 90 for Pain, 84 for Symptoms, 91 for Activities of Daily Living (ADL, 80 for Sports/Recreation, and 81 for Quality of Life (QOL. A non-satisfactory result was defined as treatment failure (TF and corresponded to a QOL score < 44. Results: All patients achieved 90 of knee flexion on the first postoperative day and full extension 2 weeks postoperatively. A full range of motion was achieved in less than 6 weeks postoperatively. No postoperative complications were reported. Score improvement at follow-up was observed in the KOOS subscales Pain, Symptoms and ADL. Criteria for FR were fulfilled by 52% of patients for Pain, 47% for Symptoms, 62% for ADL, 34% for Sports/Recreation and 15% for QOL, whereas criteria for TF were fulfilled by 29% of patients. Conclusions : The study demonstrated that the primary ACLRs without wound drainage did not have any negative impact for patient-reported recovery.

  18. Comparison of Return to Pre-Injury Sport After 10 mm Size Bone-Patellar Tendon-Bone (BPTB) versus 8 mm Hamstring Anterior Cruciate Ligament Reconstruction: A Retrospective Study with a Two-Year Follow-Up.

    Science.gov (United States)

    Gudas, Rimtautas; Jurkonis, Rokas; Smailys, Alfredas

    2018-02-17

    BACKGROUND The aim of this study was to evaluate the reconstruction of a torn anterior cruciate ligament (ACL) with 10 mm diameter BPTB (bone-patellar tendon-bone) autograft versus 8 mm HT (hamstring tendon) autografts, to compare the ability to restore pre-injury sports activities and reduce revision risk after these procedures. MATERIAL AND METHODS A prospective clinical review was performed to compare results of patients who underwent primary anatomical ACLR with 10 mm BPTB autografts with patients who underwent 8 mm diameter HT autografts, between January 2011 and January 2014. RESULTS There were 183 patients evaluated: the 8 mm HT group showed statistically significant higher knee laxity values compared to the 10 mm BPTB group (p=0.042), and significant difference were detected in subjective International Knee Documentation Committee (IKDC) evaluation scores; the average subjective IKDC evaluations after two-year follow-up in the HT group was 88.45±2.8 versus 89.24±2.5 in BPTB group (p=0.047). In the evaluation of the IKDC objective protocol, results were excellent and good in 83 patients (94.3%) after BPTB and in 78 patients (82%) after HT ACLR (p<0.05). The average score on the Tegner activity scale in the HT group decreased from 6.5 at pre-injury to 5.8 at two-year follow-up (p<0.001) and from 6.7 at pre-injury to 6.5 at two-year follow-up in the BPTB group (p=0.4). The ability to restore pre-injury sports activities was higher in the BPTB group (6.5) versus the HT group (5.8) (p<0.001). Revision was required for two patients (2.2%) in the BPTB group compared with 14 patients (14.7%) in the HT group (p<0.05). CONCLUSIONS Smaller HT graft size was a predictor of higher knee laxity and greater revision risk at two-year post primary ACL reconstruction. Larger diameter BPTB ACL grafts had a better ability to restore knee stability and greater ability to restore pre-injury sports activities.

  19. Reconstruction of chronic anterior cruciate ligament insufficiency in athletes using a bone-patellar tendon-bone autograft. A two-year follow up study.

    Science.gov (United States)

    Järvinen, M; Natri, A; Lehto, M; Kannus, P

    1995-01-01

    Thirty athletes (18 men and 12 women) were followed up for an average of 2.2 years after operative reconstruction for chronic anterior cruciate injuries with a mini-arthrotomy technique using a bone-patellar ligament-bone autograft. All the patients were active in sports, and the injuries in 40% occurred while playing soccer. The average delay between injury and reconstruction was 4.7 years; before this 26 knee operations had been carried out in 22 of the patients. At follow up, 20 patients were satisfied subjectively and 22 were classified objectively as excellent or good. Anteroposterior stability was good in 29 knees, and the Lachman and pivot shift tests were strongly positive in only one patient. Wasting of the thigh was more prominent in 9 patients who had a flexion deficit of 10 degrees or more, than in the other 21. Of the 15 competitive athletes, who had all given up their sport after injury, 8 were able to return to sport. Reconstruction using a bone-patellar ligament-bone autograft is recommended for symptomatic chronic anterior cruciate ligament insufficiency in athletes.

  20. Tear patterns, surgical repair, and clinical outcomes of patellar tendon ruptures after anterior cruciate ligament reconstruction with a bone-patellar tendon-bone autograft.

    Science.gov (United States)

    Benner, Rodney W; Shelbourne, K Donald; Urch, Scott E; Lazarus, David

    2012-08-01

    Patellar tendon ruptures are rare after graft harvest for anterior cruciate ligament (ACL) reconstruction. Few reports are available in the literature. To report the common tear patterns and results of treatment with tendon repair and cable augmentation. Case series; Level of evidence, 4. All tendon ruptures were repaired to bone with suture anchors and augmented with a Dall-Miles cable, followed by an aggressive rehabilitation protocol. The tear location was recorded. Range of motion, strength, and subjective survey testing were conducted preoperatively and postoperatively. Thirteen patellar tendon ruptures were found from our database of 5364 ACL reconstructions, for an incidence of 0.24%. Seven ruptures occurred from the patellar origin medially and the tibial attachment laterally in a Z-shaped pattern. Four were completely distal, and 2 were completely proximal ruptures. All patients exhibited early flexion loss, but 11 of 13 patients maintained full, terminal hyperextension throughout treatment. The mean postoperative side-to-side flexion deficit was 33° at 1 month, 6° at 3 months, and 3° at latest follow-up at a mean of 4.8 years after tendon repair (range, 1-16 years). By International Knee Documentation Committee (IKDC) criteria, 10 patients had normal flexion, and 3 were nearly normal at latest follow-up. Twelve patients had normal extension, and 1 had nearly normal extension at latest follow-up. Mean isokinetic quadriceps muscle strength was 68.7% of the other side at 3 months after repair and 100.0% at latest follow-up, occurring at a mean of 47.5 months (range, 12-120 months). At a mean of 2 years (range, 1-4 years) after repair, the mean modified Noyes subjective score was 89.8 ± 9.2. Patellar tendon ruptures are rare after ACL graft harvest. These ruptures usually occur in either a proximal-medial and distal-lateral pattern or an entirely distal pattern, in contrast to the proximal-only tear pattern commonly observed in unharvested patellar

  1. Mechanical properties of human bone-tendon-bone grafts preserved by different methods and radiation sterilised

    International Nuclear Information System (INIS)

    Kaminski, A.; Gut, G.

    2008-01-01

    Full text: Patellar tendon auto and allografts are commonly used in orthopaedic surgery for reconstruction of the anterior crucial ligaments (ACL). Autografts are mainly used for primary reconstruction, while allografts are useful for revision surgery. To avoid the risk of infection diseases transmission allografts should be radiation-sterilised. As radiation-sterilisation is supposed to decrease the mechanical strength of tendon tissue, it is important to establish methods of allografts preservation and sterilisation resulting in their best quality and safety. Therefore, the purpose of the study was to compare the tensile strength of the central one third of human patellar tendon (as used for ACL reconstruction), preserved by different methods (deep fresh freezing, lyophilisation) and subsequently radiation-sterilised with doses of 0 (control), 25, 50 or 100 kGy. Bone-tendon-bone grafts were prepared from cadaveric human patella tendon with both patellar and tibial attachments. BTB grafts were preserved by deep freezing, glicerolisation or lyophilisation and radiation-sterilised with doses of 0 (control), 25, 50 or 100 kGy. To estimate mechanical properties all samples were subjected to tensile tests to failure using Instron system. Before these tests all lyophilised grafts were rehydrated. We found decrease of tensile strength of irradiated grafts compared to non-irradiated controls. Obtained results of the mechanical testing of studied grafts indicate their potential usefulness for clinical applications.(Author)

  2. Effects of twisting of the graft in anterior cruciate ligament reconstruction

    NARCIS (Netherlands)

    Elmans, L.; Wymenga, A.; van Kampen, A.; van der Wielen, P.; Mommersteeg, T. J. A.; Blankevoort, L.

    2003-01-01

    In an in vitro study on six knees from cadavers, the effect of bone-patellar tendon-bone graft twist on anterior knee laxity was measured at different knee flexion angles. A motion and loading rig was used to prescribe the flexion angle, to restrain axial rotation, and to apply 100 N anterior force

  3. [Effects of autologous periosteum wrapping allogenic tendon graft on tendon-bone healing inside a bone tunnel in rabbits].

    Science.gov (United States)

    Long, Xianbin; Chen, Zhiwei; Cao, Shengjun

    2008-10-01

    To explore the situation of tendon-bone healing when allogenic tendon graft is wrapped with autologous periosteum around the tendon in rabbits. Twenty healthy New Zealand white rabbits with the age of 4-5 months were used in the experiment, weighing 2.5-3.0 kg. One-side posterior limb was selected randomly as the test, and the contralateral limb was served as the control at the same time. The allogenic tendon graft was designed as a tendon-bone model in the proximal tibial metaphysis of rabbits. The portion of tendon in the bone tunnel was wrapped with autologous periosteal graft in which the cambium layer was facing the bone tunnel in the experimental group, while the portion of tendon in the bone tunnel was not wrapped with autologous periosteal graft in the control group. The histologic examination of the tendon-bone interface (n = 2) and the biomechanical test for maximal pullout load (n = 8) were conducted 4 and 8 weeks after operation, respectively. All specimens were observed with naked eyes 4 and 8 weeks after the operation. Many new bones around bone tunnel outlet were seen in the experimental group, while a few or few new bones were seen in the control group. Four weeks after operation, histological observation showed there were a lot of proliferative mesenchymal cells in the periosteal germinal layer in the experimental group and conspicuous membrane bone formation was obvious. The arrangement of massive osteoblasts around newborn bone trabecula was similar to palisade. The newborn bone trabecula was linked with the periosteum. Some loose connective tissues and few newborn bones between the tendon graft and the bone tunnel were seen in the control group, and the connection of them was loose. Eight weeks after operation, the connection between the tendon graft and the bone tunnel was tight and no gap existed in the experimental group. The number of newborn bones was large and their arrangement was relatively regular. The tidemark line was seen between the

  4. Increased incidence of osteoarthritis of knee joint after ACL reconstruction with bone-patellar tendon-bone autografts than hamstring autografts: a meta-analysis of 1,443 patients at a minimum of 5 years.

    Science.gov (United States)

    Xie, Xiaobo; Xiao, Zhuo; Li, Qi; Zhu, Bo; Chen, Jingxian; Chen, Huamu; Yang, Fangyuan; Chen, Yuting; Lai, Qianwei; Liu, Xuzhou

    2015-01-01

    The objective of this study was to evaluate the effectiveness of BPTB autografts versus HT autografts at a minimum of 5 years after anterior cruciate ligament (ACL) reconstruction. A systematical search of literature was performed in PubMed, Embase and the Cochrane library to identify published randomized controlled trials (RCT) or prospective cohort studies (PCS) relevant to ACL reconstruction comparing BPTB and HT autografts. The results of the eligible studies were analysed in terms of objective International Knee Documentation Committee (IKDC) scores, return to preinjury activity level, KT-1000, Lachman test, pivot shift test, anterior knee pain, kneeling pain, extension loss, and flexion loss, graft failure and radiographic outcomes. Study quality was assessed by using the Coleman methodology score for included studies. Two reviewers independently assessed each study for quality and extracted data. Subgroup analysis of the primary outcomes was conducted according to the type of study design (RCT or PCS). Twelve RCTs, two PCS including 1,443 patients comparing hamstring and patellar tendon autografts were identified. The results of the meta-analysis showed that there were no significant differences between BPTB and HT in terms of objective IKDC score (P = 0.83), return to preinjury activity (P = 0.69), KT-1000 (P = 0.12), Lachman test (P = 0.76), pivot shift test (P = 0.11), extension deficit (P = 0.09), flexion deficit (P = 0.71) and graft failure (P = 0.22). However, outcomes in favour of HT autografts were found in terms of anterior knee pain (P = 0.0001) and kneeling pain (P = 0.001). Radiographic evidence of osteoarthritis (OA) showed that incidence of OA was significantly higher in BPTB groups compared with HT groups based on IKDC system. These findings were still robust during the sensitivity analysis. Results from subgroup analysis of the primary outcomes were consistent with the overall analysis. Meta-analysis of prospective trials did not detect any

  5. A comparison of hamstring autograft versus bone patella tendon bone autograft for reconstruction of anterior cruciate ligament: A prospective study of 30 cases

    Directory of Open Access Journals (Sweden)

    Sanjay Deo

    2013-01-01

    Full Text Available Background and Aim: Anterior cruciate ligament (ACL deficient knee usually present with instability of the knee, in our study we are comparing the results of ACL reconstruction using bone-patellar-bone and quadrupled stranded hamstring tendon grafts. Materials and Methods: Thirty patients presenting with chief complaints of the knee instability were diagnosed clinically by Lachman test, anterior drawer test, pivot shift test and confirmed by diagnostic arthroscopy or MRI to have ACL tear. ACL tears that are more than 6 weeks old are included. Fifteen patients were treated with ACL reconstruction using autologous ipsilateral hamstringtendon and 15 patients were treated with bone patellar tendon bone graft through arthroscopy assisted technique. All patients were reviewed and analyzed at the end of 1 year post-operatively. Assessment includes pre-operative, intra-operative findings and post-operative subjective assessment scores and examination findings, pre- and post-operatively the Lysholm score, Tegner activity level, and International Knee Documentation Committee (IKDC evaluation system were used as scoring systems. Results: Comparisons of results within the same groups showed statistically significant improvement as assessed by IKDC, Tegners and Lysholm operative scores. There was also significant correlation between manual Lachman test and stress laxometry findings. There was no statistically significant difference between scores of two groups (hamstring and bone patella tendon. Conclusions: Arthroscopic ACL reconstruction by either quadrupled hamstring tendon graft or bone patellar tendon graft gives equally satisfactory results.

  6. The biomechanical strength of a hardware-free femoral press-fit method for ACL bone-tendon-bone graft fixation.

    Science.gov (United States)

    Arnold, M P; Burger, L D; Wirz, D; Goepfert, B; Hirschmann, M T

    2017-04-01

    The purpose was to investigate graft slippage and ultimate load to failure of a femoral press-fit fixation technique for anterior cruciate ligament (ACL) reconstruction. Nine fresh-frozen knees were used. Standardized harvesting of the B-PT-B graft was performed. The femora were cemented into steel rods, and a tunnel was drilled outside-in into the native ACL footprint and expanded using a manual mill bit. The femoral bone block was fixed press-fit. To pull the free end of the graft, it was fixed to a mechanical testing machine using a deep-freezing technique. A motion capture system was used to assess three-dimensional micro-motion. After preconditioning of the graft, 1000 cycles of tensile loading were applied. Finally, an ultimate load to failure test was performed. Graft slippage in mm ultimate load to failure as well as type of failure was noted. In six of the nine measured specimens, a typical pattern of graft slippage was observed during cyclic loading. For technical reasons, the results of three knees had to be discarded. 78.6 % of total graft slippage occurred in the first 100 cycles. Once the block had settled, graft slippage converged to zero, highlighting the importance of initial preconditioning of the graft in the clinical setting. Graft slippage after 1000 cycles varied around 3.4 ± 3.2 mm (R = 1.3-9.8 mm) between the specimens. Ultimate loading (n = 9) revealed two characteristic patterns of failure. In four knees, the tendon ruptured, while in five knees the bone block was pulled out of the femoral tunnel. The median ultimate load to failure was 852 N (R = 448-1349 N). The implant-free femoral press-fit fixation provided adequate primary stability with ultimate load to failure pull forces at least equal to published results for interference screws; hence, its clinical application is shown to be safe.

  7. The microstructure and micromechanics of the tendon-bone insertion

    Science.gov (United States)

    Rossetti, L.; Kuntz, L. A.; Kunold, E.; Schock, J.; Müller, K. W.; Grabmayr, H.; Stolberg-Stolberg, J.; Pfeiffer, F.; Sieber, S. A.; Burgkart, R.; Bausch, A. R.

    2017-06-01

    The exceptional mechanical properties of the load-bearing connection of tendon to bone rely on an intricate interplay of its biomolecular composition, microstructure and micromechanics. Here we identify that the Achilles tendon-bone insertion is characterized by an interface region of ~500 μm with a distinct fibre organization and biomolecular composition. Within this region, we identify a heterogeneous mechanical response by micromechanical testing coupled with multiscale confocal microscopy. This leads to localized strains that can be larger than the remotely applied strain. The subset of fibres that sustain the majority of loading in the interface area changes with the angle of force application. Proteomic analysis detects enrichment of 22 proteins in the interfacial region that are predominantly involved in cartilage and skeletal development as well as proteoglycan metabolism. The presented mechanisms mark a guideline for further biomimetic strategies to rationally design hard-soft interfaces.

  8. Outcomes of the patellar tendon and hamstring graft anterior cruciate ligament reconstructions in patients aged above 50 years

    Directory of Open Access Journals (Sweden)

    Tarun Bali

    2015-01-01

    Full Text Available Background: The treatment of anterior cruciate ligament (ACL injury consists of arthroscopic ACL reconstruction with patellar tendon or hamstring graft. Satisfactory results have been reported so far in the younger age group. Dilemma arises regarding the suitability of ACL reconstruction in the patients aged 50 years and above. This retrospective analyses the outcome of ACL reconstruction in patients aged 50 years and above at the time of presentation. Materials and Methods: 55 patients aged 50 years and above presented to our institution with symptomatic ACL tear and were managed with arthroscopic reconstruction with patellar tendon/hamstring graft. 22 patients underwent ACL reconstruction with bone- patellar tendon-bone graft and the remaining 33 with a hamstring graft. Evaluation of functional outcome was performed using International Knee Documentation Committee (IKDC and Lysholm scoring in the preoperative period, at the end of 1 year and at the final followup. Radiographic evaluation was performed using the Kellgren–Lawrence grading system. Results: The mean preoperative IKDC score was 39.7 ± 3.3. At the end of 1-year following the operation, the mean IKDC score was 73.6 ± 4.9 and at the final followup was 67.8 ± 7.7. The mean preoperative Lysholm score was 40.4 ± 10.3. At the end of 1-year following the intervention, the mean Lysholm score was 89.7 ± 2.1 and at final followup was 85.3 ± 2.5. Overall, 14 out of 42 patients who underwent radiographic assessment showed progression of osteoarthritis changes at the final followup after the intervention. Conclusion: In our study, there was a statistically significant improvement in the IKDC and Lysholm scores following the intervention. There was a slight deterioration in the scores at the final followup but the overall rate of satisfaction was still high and most of the patients were able to do their routine chores and light exercises suitable for their age group. Around one-third of

  9. Biology and augmentation of tendon-bone insertion repair

    Directory of Open Access Journals (Sweden)

    Lui PPY

    2010-08-01

    Full Text Available Abstract Surgical reattachment of tendon and bone such as in rotator cuff repair, patellar-patella tendon repair and anterior cruciate ligament (ACL reconstruction often fails due to the failure of regeneration of the specialized tissue ("enthesis" which connects tendon to bone. Tendon-to-bone healing taking place between inhomogenous tissues is a slow process compared to healing within homogenous tissue, such as tendon to tendon or bone to bone healing. Therefore special attention must be paid to augment tendon to bone insertion (TBI healing. Apart from surgical fixation, biological and biophysical interventions have been studied aiming at regeneration of TBI healing complex, especially the regeneration of interpositioned fibrocartilage and new bone at the healing junction. This paper described the biology and the factors influencing TBI healing using patella-patellar tendon (PPT healing and tendon graft to bone tunnel healing in ACL reconstruction as examples. Recent development in the improvement of TBI healing and directions for future studies were also reviewed and discussed.

  10. Functional Outcome and Graft Retention in Patients With Septic Arthritis After Anterior Cruciate Ligament Reconstruction: A Systematic Review.

    Science.gov (United States)

    Makhni, Eric C; Steinhaus, Michael E; Mehran, Nima; Schulz, Brian S; Ahmad, Christopher S

    2015-07-01

    To provide a comprehensive review of clinical and functional outcomes after treatment for septic arthritis after anterior cruciate ligament reconstruction. A systematic review of the literature was performed. Two reviewers assessed and confirmed the methodologic quality of each study. Studies that met the inclusion criteria were assessed for pertinent data, and when available, similar outcomes were combined to generate frequency-weighted means. Nineteen studies met the inclusion and exclusion criteria for this review, reporting on a total of 203 infected knees. The mean age was 27.5 years and the mean length of follow-up was 44.2 months, with male patients comprising 88% of the population. Hamstring and bone-patellar tendon-bone autografts were used in 63% and 33% of patients, respectively, with 78% of patients retaining their grafts. The studies reported mean flexion and extension deficits of 5.8° and 1.0°, respectively, and laxity testing showed a mean difference of 1.9 mm. The studies reported mean Lysholm, International Knee Documentation Committee, and Tegner scores of 82.1, 68.2, and 5.6, respectively. Of the patients, 83% reported an ability to return to activities of daily living whereas 67% reported a return to their preinjury level of athletics. Evidence of new degenerative changes was seen in 22% of patients. Septic arthritis after anterior cruciate ligament reconstruction remains a very infrequent event, affecting 0.5% of patients. On average, outcomes in these patients are comparable with those in patients in whom infection does not develop, including postoperative range of motion, residual instability, Lysholm scores, and return to preinjury level of activity. These patients do exhibit decreased International Knee Documentation Committee scores compared with patients without septic arthritis, however. The impact of this differential is not clear, but this scoring difference suggests that septic arthritis may be associated with more severe symptoms

  11. Mechanical Loading Improves Tendon-Bone Healing in a Rabbit Anterior Cruciate Ligament Reconstruction Model by Promoting Proliferation and Matrix Formation of Mesenchymal Stem Cells and Tendon Cells

    Directory of Open Access Journals (Sweden)

    Fanglong Song

    2017-02-01

    Full Text Available Background/Aims: This study investigated the effect of mechanical stress on tendon-bone healing in a rabbit anterior cruciate ligament (ACL reconstruction model as well as cell proliferation and matrix formation in co-culture of bone-marrow mesenchymal stem cells (BMSCs and tendon cells (TCs. Methods: The effect of continuous passive motion (CPM therapy on tendon-bone healing in a rabbit ACL reconstruction model was evaluated by histological analysis, biomechanical testing and gene expressions at the tendon-bone interface. Furthermore, the effect of mechanical stretch on cell proliferation and matrix synthesis in BMSC/TC co-culture was also examined. Results: Postoperative CPM therapy significantly enhanced tendon-bone healing, as evidenced by increased amount of fibrocartilage, elevated ultimate load to failure levels, and up-regulated gene expressions of Collagen I, alkaline phosphatase, osteopontin, Tenascin C and tenomodulin at the tendon-bone junction. In addition, BMSC/TC co-culture treated with mechanical stretch showed a higher rate of cell proliferation and enhanced expressions of Collagen I, Collagen III, alkaline phosphatase, osteopontin, Tenascin C and tenomodulin than that of controls. Conclusion: These results demonstrated that proliferation and differentiation of local precursor cells could be enhanced by mechanical stimulation, which results in enhanced regenerative potential of BMSCs and TCs in tendon-bone healing.

  12. The effects of low-intensity pulsed ultrasound on tendon-bone healing in a transosseous-equivalent sheep rotator cuff model.

    Science.gov (United States)

    Lovric, Vedran; Ledger, Michael; Goldberg, Jerome; Harper, Wade; Bertollo, Nicky; Pelletier, Matthew H; Oliver, Rema A; Yu, Yan; Walsh, William R

    2013-02-01

    The purpose of this study was to examine the effects Low-intensity Pulsed Ultrasound has on initial tendon-bone healing in a clinically relevant extra-articular transosseous-equivalent ovine rotator cuff model. Eight skeletally mature wethers, randomly allocated to either control group (n = 4) or treatment group (n = 4), underwent rotator cuff surgery following injury to the infraspinatus tendon. All animals were killed 28 days post surgery to allow examination of early effects of Low-intensity Pulsed Ultrasound treatment. General improvement in histological appearance of tendon-bone integration was noted in the treatment group. Newly formed woven bone with increased osteoblast activity along the bone surface was evident. A continuum was observed between the tendon and bone in an interdigitated fashion with Sharpey's fibres noted in the treatment group. Low-intensity Pulsed Ultrasound treatment also increased bone mineral density at the tendon-bone interface (p < 0.01), while immunohistochemistry results revealed an increase in the protein expression patterns of VEGF (p = 0.038), RUNX2 (p = 0.02) and Smad4 (p = 0.05). The results of this study indicate that Low-intensity Pulsed Ultrasound may aid in the initial phase of tendon-bone healing process in patients who have undergone rotator cuff repair. This treatment may also be beneficial following other types of reconstructive surgeries involving the tendon-bone interface.

  13. ACL Reconstruction With Autografts Weighing Performance Considerations and Postoperative Care.

    Science.gov (United States)

    Grant, John A; Mohtadi, Nicholas G

    2003-04-01

    Anterior cruciate ligament (ACL) reconstruction is the treatment of choice for patients who experience episodes of instability and a decreased quality of life after ACL rupture. The bone-patellar tendon-bone and hamstring autografts are the current standards for ACL reconstruction. Primary care physicians, especially sports medicine clinicians, are the first-line providers of nonoperative care for patients who have ACL injuries. Care providers need to know the biologic and biomechanic properties of these grafts, clinical indications for each graft, and rehabilitation considerations to appropriately counsel their patients.

  14. In vivo evaluation of two types of bioactive scaffold used for tendon-bone interface healing in the reconstruction of anterior cruciate ligament.

    Science.gov (United States)

    Zhang, Weibin; Pan, Weimin; Zhang, Mingjun; Wei, Yiyong

    2011-04-01

    Fibrin glue combined with bone morphogenetic protein (BMP) and recombined bone xenograft (RBX), were compared to evaluate their effect on the tendon-bone interface healing. The interface of fibrin glue-BMP developed new cartilage but the new bone was thinner whereas the interface of RBX had large areas of chondrocyte-like cells, bone formation and an immature neo-enthesis structure. At 12 weeks, bone mineral density of RBX group (152 ± 52 cm(3)) and fibrin glue-BMP group (109 ± 13 cm(3)) was calculated by micro-computed tomography. The ultimate load of fibrin glue-BMP group (60 ± 18 and 51 ± 14 N) and RBX group (65 ± 21 and 57 ± 15 N) was shown by biomechanics at 6 and 12 weeks. RBX thus has an advantage on accelerating tendon-bone interface healing.

  15. Iliotibial band autograft versus bone-patella-tendon-bone autograft, a possible alternative for ACL reconstruction

    DEFF Research Database (Denmark)

    Stensbirk, Frederik; Thorborg, Kristian; Konradsen, Lars

    2014-01-01

    reconstruction. Forty-nine participated at follow-up in 2010 (82%). Primary outcome was the failure rate after ACL reconstruction. Secondary outcomes were knee injury osteoarthritis outcome score (KOOS) [pain, symptoms, Sport/Rec, quality of life (QOL), daily living function], Tegner activity scale, anterior...... knee pain-score, Lysholm score, Rolimeter laxity, extension deficit, single hop and crossover hop for distance. RESULTS: At 15-year follow-up, no significant difference existed between the groups. Graft failure occurred in 4 ITB subjects (16%) and 3 BPTB subjects (13%). KOOS (Sport/Rec) for the ITB...

  16. The Masticatory Contractile Load Induced Expression and Activation of Akt1/PKBα in Muscle Fibers at the Myotendinous Junction within Muscle-Tendon-Bone Unit

    Directory of Open Access Journals (Sweden)

    Yüksel Korkmaz

    2010-01-01

    Full Text Available The cell specific detection of enzyme activation in response to the physiological contractile load within muscle-tendon-bone unit is essential for understanding of the mechanical forces transmission from muscle cells via tendon to the bone. The hypothesis that the physiological mechanical loading regulates activation of Akt1/PKBα at Thr308 and at Ser473 in muscle fibers within muscle-tendon-bone unit was tested using quantitative immunohistochemistry, confocal double fluorescence analysis, and immunoblot analysis. In comparison to the staining intensities in peripheral regions of the muscle fibers, Akt1/PKBα was detected with a higher staining intensity in muscle fibers at the myotendinous junction (MTJ areas. In muscle fibers at the MTJ areas, Akt1/PKBα is dually phosphorylated at Thr308 and Ser473. The immunohistochemical results were confirmed by immunoblot analysis. We conclude that contractile load generated by masticatory muscles induces local domain-dependent expression of Akt1/PKBα as well as activation by dually phosphorylation at Thr308 and Ser473 in muscle fibers at the MTJ areas within muscle-tendon-bone unit.

  17. [Evaluation of early physiotherapy in patients after surgical treatment of cruciate ligament injury by bone-tendon-bone method].

    Science.gov (United States)

    Klupiński, Kamil; Krekora, Katarzyna; Woldańska-Okońska, Marta

    2014-01-01

    Anterior cruciate ligament (ACL) is one of the most important structures of the knee joint. It has a stabilizing function and causes sliding movement between the articular surfaces. Most frequently there comes to the anterior cruciate ligament injury during practicing sports such as skiing, football, sports which require sudden turns and those which are associated with jumps for height like basketball and volleyball. The aim of study was to evaluate of the outcomes of complex physiotherapy after reconstruction of anterior cruciate ligament by bone -tendon-bone (BTB) method. The study involved 41 patients, 8 women and 33 men, aged 20 to 45 years, body height 1.60-1.90 cm and body weight 50-100 kg. The patients were divided into two groups. Group I included 26 patients (3 women and 23 men) after arthroscopic ACL reconstruction. Group II--control-group included 15 patients (5 women and 10 men) after ACL injury but not subjected to the ligament reconstruction. The patients from both groups underwent rehabilitation according to the same rehabilitation program suggested by the Medical Magnus Clinic in Lodz, which consisted in performing daily exercises in open and closed kinetic chains. All group I and II patients were examined three times: after surgery (before the start of the rehabilitation), in the sixth week of rehabilitation and 12 weeks afterwards. The clinical examination included: measurement of the range of movement in the knee joint, the measurement of musculoskeletal strength with Lovett scale, knee pain assessment using Visual Analog Scale (VAS), transpatellar anthropometric measurement of the knee joint, linear measurements of the thigh and shin (at two points: 5 and 10 cm above the patellar apex and at two points: 5 and 10 cm below the patellar base). Introduction of early highly specialized physiotherapy has been demonstrated to contribute to the improvement of the rehabilitation outcomes and to the shortening of the therapy. A statistically significant

  18. The effect of platelet rich plasma from bone marrow aspirate with added bone morphogenetic protein-2 on the Achilles tendon-bone junction in rabbits.

    Science.gov (United States)

    Kim, Hak Jun; Nam, Hyok-Woo; Hur, Chang-Yong; Park, Misu; Yang, Hee Seok; Kim, Byung-Soo; Park, Jung-Ho

    2011-12-01

    To determine if exogenously injected bone marrow derived platelet-rich plasma (PRP) plus bone morphogenetic protein (BMP)-2 could accelerate the healing of bone-tendon junction injuries and increase the junction holding strength during the early regeneration period. A direct injury model of the bone-tendon junction was made using an Achilles tendon-calcaneus bone junction in a rabbit. In the PRP/BMP-2/fibrin group, 0.05 mL of bone marrow derived PRP and 100 ng/mL of BMP-2 both incorporated into 0.1 mL of fibrin glue were injected into Achilles tendon-calcaneus bone junctions. The effect of the intervention was tested by comparing the results of an intervention group to a control group. The results of biomechanical testing, and histological and gross analyses were compared between the 2 groups at the following time points after surgery: 2 weeks, 4 weeks, and 8 weeks. Histologic examinations showed that woven bone developed in tendon-bone junctions at 2 weeks after surgery in the PRP/BMP-2/fibrin group. Mechanical test results showed no significant difference between the PRP/BMP-2/fibrin and control groups at 2 and 4 weeks after surgery, but the mean maximal load in the PRP/BMP-2/fibrin group was significantly higher than in the control group (p rabbit model of tendon-bone junction injury.

  19. Anterior cruciate ligament reconstruction autograft choice: bone-tendon-bone versus hamstring: does it really matter? A systematic review.

    Science.gov (United States)

    Spindler, Kurt P; Kuhn, John E; Freedman, Kevin Blake; Matthews, Charles E; Dittus, Robert S; Harrell, Frank E

    2004-12-01

    Anterior cruciate ligament graft choice is controversial, with no evidence-based consensus available to guide decision making. The study design was evidence-based medicine systematic review of randomized controlled trials evaluating patellar tendon versus hamstring tendon autografts. A literature review identified 9 randomized controlled trials comparing patellar tendon and hamstring tendon autografts. An evidence-based systematic review was performed. Objective and subjective outcomes of interest included surgical technique, rehabilitation, instrumented laxity, isokinetic strength, patellofemoral pain, return to preinjury activity, and Tegner, Lysholm, Cincinnati, and International Knee Documentation Committee-1991 scores. Additional surgery, graft failure, and complications were reviewed. Slight increased laxity on arthrometer testing was seen in the hamstring population in 3 of 7 studies. Pain with kneeling was greater for the patellar tendon population in 4 of 4 studies. Only 1 of 9 studies showed increased anterior knee pain in the patellar tendon group. Frequency of additional surgery seemed to be related to the fixation method and not graft type. No study reported a significant difference in graft failure between patellar tendon and hamstring tendon autografts. Objective differences (range of motion, isokinetic strength, arthrometer testing) were not detected between groups in the majority of studies, suggesting that their sensitivity to detect clinical outcomes may be limited. Increased kneeling pain in the patellar tendon group was seen consistently in the studies evaluated. Subjective differences in anterior knee pain or return-to-activity level were not consistently observed in these studies. With numbers available, failure rates were not significantly different between groups. These findings suggest that graft type may not be the primary determinant for successful outcomes after anterior cruciate ligament surgery.

  20. [Effect of intermittent negative pressure on matrix metalloproteinase 9 and transforming growth factor β of tendon-bone interface and joint fluid after reconstruction of anterior cruciate ligament in rabbits].

    Science.gov (United States)

    Sun, Z M; Dong, X H; Sun, Z J; Chang, Y H; Wu, X Y; Yi, Z; Ling, M

    2017-12-05

    Objective: To study the effect of intermittent negative pressure on matrix metalloproteinase 9 (MMP)-9 and transforming growth factor β of tendon-bone interface and joint fluid after reconstruction of anterior cruciate ligament in rabbits. Methods: A total of twenty-four New Zealand white rabbits were randomly selected hind leg of negative group, contralateral hind leg as control.Reconstruction of the anterior cruciate ligament was done by autogenous semitendinosus of rabbit.Joint of the negative pressure side placed drainage tube connecting the micro-negative pressure aspirator, and maintained an intermittent, low-intensity negative pressure.Control side placed ordinary drainage tube.Drainage tube of both sides was pulled out at the same time after 5 days.After 6 weeks, joint fluid and femur-ligament-tibia complex were obtained for study of expression of MMP-9 and TGF-β in joint fluid and tendon-bone interface. Result: Twenty-three rabbits were included in the study because of one rabbit joint infections.Detection of joint fluid showed that MMP-9 content is significantly lower in negative group than that in the control group, and the difference is statistically significant [(8.9±1.3) pg/L vs (12.3±1.8) pg/L ( P =0.002)]. TGF-β content is significantly higher in negative group in joint fluid than that in the control group, and the difference is statistically significant [(19.0±2.2) pg/L vs (15.2±1.4) pg/L ( P =0.000)]. Study of immunohistochemistry in tendon-bone interface found that expression of MMP-9 is lower in negative pressure group than that in the control group, and the difference is statistically significant ( P =0.000). TGF-β expression is significantly higher in negative group in tendon-bone interface than that in the control group, and the difference is statistically significant ( P =0.000). Conclusion: Intermittent negative pressure may reduce content of MMP-9 in joint fluid and expression of MMP-9 in tendon-bone interface, increase content of

  1. Magnesium inference screw supports early graft incorporation with inhibition of graft degradation in anterior cruciate ligament reconstruction

    Science.gov (United States)

    Cheng, Pengfei; Han, Pei; Zhao, Changli; Zhang, Shaoxiang; Zhang, Xiaonong; Chai, Yimin

    2016-05-01

    Patients after anterior cruciate ligament (ACL) reconstruction surgery commonly encounters graft failure in the initial phase of rehabilitation. The inhibition of graft degradation is crucial for the successful reconstruction of the ACL. Here, we used biodegradable high-purity magnesium (HP Mg) screws in the rabbit model of ACL reconstruction with titanium (Ti) screws as a control and analyzed the graft degradation and screw corrosion using direct pull-out tests, microCT scanning, and histological and immunohistochemical staining. The most noteworthy finding was that tendon graft fixed by HP Mg screws exhibited biomechanical properties substantially superior to that by Ti screws and the relative area of collagen fiber at the tendon-bone interface was much larger in the Mg group, when severe graft degradation was identified in the histological analysis at 3 weeks. Semi-quantitative immunohistochemical results further elucidated that the MMP-13 expression significantly decreased surrounding HP Mg screws with relatively higher Collagen II expression. And HP Mg screws exhibited uniform corrosion behavior without displacement or loosening in the femoral tunnel. Therefore, our results demonstrated that Mg screw inhibited graft degradation and improved biomechanical properties of tendon graft during the early phase of graft healing and highlighted its potential in ACL reconstruction.

  2. No effect of Osteoset, a bone graft substitute, on bone healing in humans: a prospective randomized double-blind study

    DEFF Research Database (Denmark)

    Petruskevicius, Juozas; Nielsen, Mette Strange; Kaalund, Søren

    2002-01-01

    We studied the effects of a newly marketed bone substitute, Osteoset, on bone healing in a tibial defect in humans. 20 patients undergoing an ACL (anterior cruciate ligament) reconstruction with bone-patella tendon-bone graft were block-randomized into 2 groups of 10 each. In the treatment group......, the tibial defect was filled manually with Osteoset pellets, in the control group the defect was left empty. CTs of the defect were taken on the first day after the operation, 6 weeks, 3 and 6 months postoperatively. We found about the same amount of bone in the defect in the Osteoset and control groups...

  3. Successful anterior cruciate ligament reconstruction and meniscal repair in osteogenesis imperfecta.

    Science.gov (United States)

    Park, Jae-Young; Cho, Tae-Joon; Lee, Myung Chul; Han, Hyuk-Soo

    2018-03-20

    A case of anterior cruciate ligament (ACL) reconstruction with meniscal repair in an osteogenesis imperfecta patient is reported. A 24-year-old female with osteogenesis imperfecta type 1a suffered from a valgus extension injury resulting in tear of ACL and medial meniscus. She underwent an arthroscopic-assisted ACL reconstruction and medial meniscus repair. Meniscal tear at the menisco-capsular junction of the posterior horn of medial meniscus was repaired with three absorbable sutures via inside-out technique. ACL reconstruction was then performed with a bone-patellar tendon-bone allograft. The patient was followed up for 1 year with intact ACL grafts and healed medial meniscus. This case report showed that successful ACL reconstruction and meniscal repair is possible in an osteogenesis imperfecta patient.Level of evidence V.

  4. A biomechanical comparison of tendon-bone interface motion and cyclic loading between single-row, triple-loaded cuff repairs and double-row, suture-tape cuff repairs using biocomposite anchors.

    Science.gov (United States)

    Barber, F Alan; Drew, Otis R

    2012-09-01

    To compare tendon-bone interface motion and cyclic loading in a single-row, triple-loaded anchor repair with a suture-tape, rip-stop, double-row rotator cuff repair. Using 18 human shoulders from 9 matched cadaveric pairs, we created 2 groups of rotator cuff repairs. Group 1 was a double-row, rip-stop, suture-tape construct. Group 2 was a single-row, triple-loaded construct. Before mechanical testing, the supraspinatus footprint was measured with calipers. A superiorly positioned digital camera optically measured the tendon footprint motion during 60° of humeral internal and external rotation. Specimens were secured at a fixed angle not exceeding 45° in reference to the load. After preloading, each sample was cycled between 10 N and 100 N for 200 cycles at 1 Hz, followed by destructive testing at 33 mm/s. A digital camera with tracking software measured the repair displacement at 100 and 200 cycles. Ultimate load and failure mode for each sample were recorded. The exposed anterior footprint border (6.5% ± 6%) and posterior footprint border (0.9% ± 1.7%) in group 1 were statistically less than the exposed anterior footprint border (30.3% ± 17%) and posterior footprint border (29.8% ± 14%) in group 2 (P = .003 and P footprint displacements in group 1 (1.6 mm and 1.4 mm, respectively) were less than those in group 2 (both 3.6 mm) (P = .007 and P = .004, respectively). Mean displacement after 100 cycles for group 1 and group 2 was 2.0 mm and 3.2 mm, respectively, and at 200 cycles, mean displacement was 2.5 mm and 4.2 mm, respectively (P = .02). The mean ultimate failure load in group 1 (586 N) was greater than that in group 2 (393 N) (P = .02). The suture-tendon interface was the site of most construct failures. The suture-tape, rip-stop, double-row rotator cuff repair had greater footprint coverage, less rotational footprint displacement, and a greater mean ultimate failure load than the triple-loaded, single-row repair on mechanical testing. No double-row or

  5. Anterior Cruciate Reconstruction Using Bone-patellar Ligament ...

    African Journals Online (AJOL)

    A few complications occurred with one infection and calcification of ligament in two patients, arthrofibrosis in two patients. Conclusion: This study is of clinical relevance as it shows alleviation of pain after surgical treatment of the torn ACL which has been described as the stabiliser of the knee and guardian of the Meniscus.

  6. Comparison of Three Patellar Tendon Anterior Cruciate Ligament Reconstruction Techniques with Emphasis on Tunnel Location and Outcome. Are Our Results Improving?

    OpenAIRE

    Merchant, Thomas C

    2001-01-01

    In order to determine if recent changes in tunnel placement during anterior cruciate ligament reconstruction are producing better outcomes, the results of three different "bone-patellar tendon-bone" anterior cruciate ligament reconstruction techniques were compared. These techniques were: two-incision with the tibial tunnel at the anterior "footprint" of the anterior cruciate ligament (group I), two-incision with freehand placement of the tibial tunnel in the central or posterior "footprint" ...

  7. Stent graft placement for dysfunctional arteriovenous grafts

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. Eleven patients who underwent stent graft placement for a dysfunctional hemodialysis graft were included in this retrospective study. Expanded polytetrafluoroethylene covered stent grafts were placed at the venous anastomosis site in case of pseudoaneurysm, venous laceration, elastic recoil or residual restenosis despite the repeated angioplasty. The patency of the arteriovenous graft was evaluated using Kaplan-Meier analysis. Primary and secondary mean patency was 363 days and 741 days. Primary patency at 3, 6, and 12 months was 82%, 73%, and 32%, respectively. Secondary patency at the 3, 6, 12, 24, and 36 months was improved to 91%, 82%, 82%, 50%, and 25%, respectively. Fractures of the stent graft were observed in 2 patients, but had no effect on the patency. Stent graft placement in dysfunctional arteriovenous graft is useful and effective in prolonging graft patency.

  8. Effects of ACL Reconstructive Surgery on Temporal Variations of Cytokine Levels in Synovial Fluid

    Directory of Open Access Journals (Sweden)

    Marco Bigoni

    2016-01-01

    Full Text Available Anterior cruciate ligament (ACL reconstruction restores knee stability but does not reduce the incidence of posttraumatic osteoarthritis induced by inflammatory cytokines. The aim of this research was to longitudinally measure IL-1β, IL-6, IL-8, IL-10, and TNF-α levels in patients subjected to ACL reconstruction using bone-patellar tendon-bone graft. Synovial fluid was collected within 24–72 hours of ACL rupture (acute, 1 month after injury immediately prior to surgery (presurgery, and 1 month thereafter (postsurgery. For comparison, a “control” group consisted of individuals presenting chronic ACL tears. Our results indicate that levels of IL-6, IL-8, and IL-10 vary significantly over time in reconstruction patients. In the acute phase, the levels of these cytokines in reconstruction patients were significantly greater than those in controls. In the presurgery phase, cytokine levels in reconstruction patients were reduced and comparable with those in controls. Finally, cytokine levels increased again with respect to control group in the postsurgery phase. The levels of IL-1β and TNF-α showed no temporal variation. Our data show that the history of an ACL injury, including trauma and reconstruction, has a significant impact on levels of IL-6, IL-8, and IL-10 in synovial fluid but does not affect levels of TNF-α and IL-1β.

  9. Bone grafting: An overview

    Directory of Open Access Journals (Sweden)

    D. O. Joshi

    2010-08-01

    Full Text Available Bone grafting is the process by which bone is transferred from a source (donor to site (recipient. Due to trauma from accidents by speedy vehicles, falling down from height or gunshot injury particularly in human being, acquired or developmental diseases like rickets, congenital defects like abnormal bone development, wearing out because of age and overuse; lead to bone loss and to replace the loss we need the bone grafting. Osteogenesis, osteoinduction, osteoconduction, mechanical supports are the four basic mechanisms of bone graft. Bone graft can be harvested from the iliac crest, proximal tibia, proximal humerus, proximal femur, ribs and sternum. An ideal bone graft material is biologically inert, source of osteogenic, act as a mechanical support, readily available, easily adaptable in terms of size, shape, length and replaced by the host bone. Except blood, bone is grafted with greater frequency. Bone graft indicated for variety of orthopedic abnormalities, comminuted fractures, delayed unions, non-unions, arthrodesis and osteomyelitis. Bone graft can be harvested from the iliac crest, proximal tibia, proximal humerus, proximal femur, ribs and sternum. By adopting different procedure of graft preservation its antigenicity can be minimized. The concept of bone banking for obtaining bone grafts and implants is very useful for clinical application. Absolute stability require for successful incorporation. Ideal bone graft must possess osteogenic, osteoinductive and osteocon-ductive properties. Cancellous bone graft is superior to cortical bone graft. Usually autologous cancellous bone graft are used as fresh grafts where as allografts are employed as an alloimplant. None of the available type of bone grafts possesses all these properties therefore, a single type of graft cannot be recomm-ended for all types of orthopedic abnormalities. Bone grafts and implants can be selected as per clinical problems, the equipments available and preference of

  10. Grafting and curing

    International Nuclear Information System (INIS)

    Garnett, J.L.; Loo-Teck Ng; Visay Viengkhou

    1998-01-01

    Progress in radiation grafting and curing is briefly reviewed. The two processes are shown to be mechanistically related. The parameters influencing yields are examined particularly for grafting. For ionising radiation grafting systems (EB and gamma ray) these include solvents, substrate and monomer structure, dose and dose-rate, temperature and more recently role of additives. In addition, for UV grafting, the significance of photoinitiators is discussed. Current applications of radiation grafting and curing are outlined. The recent development of photoinitiator free grafting and curing is examined as well as the potential for the new excimer laser sources. The future application of both grafting and curing is considered, especially the significance of the occurrence of concurrent grafting during cure and its relevance in environmental considerations

  11. Bone grafts in dentistry

    Directory of Open Access Journals (Sweden)

    Prasanna Kumar

    2013-01-01

    Full Text Available Bone grafts are used as a filler and scaffold to facilitate bone formation and promote wound healing. These grafts are bioresorbable and have no antigen-antibody reaction. These bone grafts act as a mineral reservoir which induces new bone formation.

  12. An in vitro biomechanical comparison of anterior cruciate ligament reconstruction: single bundle versus anatomical double bundle techniques

    Directory of Open Access Journals (Sweden)

    Sandra Umeda Sasaki

    2008-01-01

    Full Text Available INTRODUCTION: Anterior cruciate ligament ruptures are frequent, especially in sports. Surgical reconstruction with autologous grafts is widely employed in the international literature. Controversies remain with respect to technique variations as continuous research for improvement takes place. One of these variations is the anatomical double bundle technique, which is performed instead of the conventional single bundle technique. More recently, there has been a tendency towards positioning the two bundles through double bone tunnels in the femur and tibia (anatomical reconstruction. OBJECTIVES: To compare, through biomechanical tests, the practice of anatomical double bundle anterior cruciate ligament reconstruction with a patellar graft to conventional single bundle reconstruction with the same amount of patellar graft in a paired experimental cadaver study. METHODS: Nine pairs of male cadaver knees ranging in age from 44 to 63 years were randomized into two groups: group A (single bundle and group B (anatomical reconstruction. Each knee was biomechanically tested under three conditions: intact anterior cruciate ligament, reconstructed anterior cruciate ligament, and injured anterior cruciate ligament. Maximum anterior dislocation, rigidity, and passive internal tibia rotation were recorded with knees submitted to a 100 N horizontal anterior dislocation force applied to the tibia with the knees at 30, 60 and 90 degrees of flexion. RESULTS: There were no differences between the two techniques for any of the measurements by ANOVA tests. CONCLUSION: The technique of anatomical double bundle reconstruction of the anterior cruciate ligament with bone-patellar tendon-bone graft has a similar biomechanical behavior with regard to anterior tibial dislocation, rigidity, and passive internal tibial rotation.

  13. Engineered vascularized bone grafts

    OpenAIRE

    Tsigkou, Olga; Pomerantseva, Irina; Spencer, Joel A.; Redondo, Patricia A.; Hart, Alison R.; O’Doherty, Elisabeth; Lin, Yunfeng; Friedrich, Claudia C.; Daheron, Laurence; Lin, Charles P.; Sundback, Cathryn A.; Vacanti, Joseph P.; Neville, Craig

    2010-01-01

    Clinical protocols utilize bone marrow to seed synthetic and decellularized allogeneic bone grafts for enhancement of scaffold remodeling and fusion. Marrow-derived cytokines induce host neovascularization at the graft surface, but hypoxic conditions cause cell death at the core. Addition of cellular components that generate an extensive primitive plexus-like vascular network that would perfuse the entire scaffold upon anastomosis could potentially yield significantly higher-quality grafts. W...

  14. Anterior cruciate ligament anatomy and function relating to anatomical reconstruction.

    Science.gov (United States)

    Zantop, Thore; Petersen, Wolf; Sekiya, Jon K; Musahl, Volker; Fu, Freddie H

    2006-10-01

    Recently, the interest in surgical techniques that reconstruct the anteromedial (AM) and the posterolateral (PL) bundles of the anterior cruciate ligament (ACL) has risen. This review focuses on the structural as well as the mechanical properties of the ACL and the anatomical details of the femoral origin, midsubstance, and tibial insertion of AM and PL bundles of the ACL. The terminology of AM and PL bundles is chosen according to the tibial insertion and determined by their functional tensioning pattern throughout knee flexion. Close to extension the AM is moderately loose and the PL is tight. As the knee is flexed, the femoral attachment of the ACL becomes more horizontally oriented, causing the AM bundle to tighten and the PM bundle to loosen up. The ACL has been described to be restraint to anterior tibial displacement and internal tibial rotation. The rotational component might be represented by the PL bundle. The femoral origin has an oval shape with the center of the AM close to over-the-top position and the center of the PL close to the anterior and inferior cartilage margin. Tibial and femoral insertions of the ACL are over 3.5 times larger when compared to the midsubstance and tunnel placement is more challenging because of the limited size of potential grafts selection of tunnel site placement. For reconstruction, both bone-patellar tendon-bone (BPTB) and quadrupled hamstring grafts are used. Structural properties of a 10 mm wide BPTB or quadrupled hamstring graft have been reported to be comparable with those of the native ACL.

  15. Osseous scintigraphy and auxiliary graft

    International Nuclear Information System (INIS)

    Khelifa, F.; Siles, S.; Puech, B.

    1992-01-01

    The scintigraphy could be a good way to survey the osseous graft: three cases are studied in which were recognized the presence of a graft, surinfection, graft lysis, pseudo-arthrosis, algodystrophy. 8 refs., 5 figs

  16. Meniscal allograft transplantation. Part 1: systematic review of graft biology, graft shrinkage, graft extrusion, graft sizing, and graft fixation.

    Science.gov (United States)

    Samitier, Gonzalo; Alentorn-Geli, Eduard; Taylor, Dean C; Rill, Brian; Lock, Terrence; Moutzouros, Vasilius; Kolowich, Patricia

    2015-01-01

    To provide a systematic review of the literature regarding five topics in meniscal allograft transplantation: graft biology, shrinkage, extrusion, sizing, and fixation. A systematic literature search was conducted using the PubMed (MEDLINE), ScienceDirect, and EBSCO-CINAHL databases. Articles were classified only in one topic, but information contained could be reported into other topics. Information was classified according to type of study (animal, in vitro human, and in vivo human) and level of evidence (for in vivo human studies). Sixty-two studies were finally included: 30 biology, 3 graft shrinkage, 11 graft extrusion, 17 graft size, and 6 graft fixation (some studies were categorized in more than one topic). These studies corresponded to 22 animal studies, 22 in vitro human studies, and 23 in vivo human studies (7 level II, 10 level III, and 6 level IV). The principal conclusions were as follows: (a) Donor cells decrease after MAT and grafts are repopulated with host cells form synovium; (b) graft preservation alters collagen network (deep freezing) and causes cell apoptosis with loss of viable cells (cryopreservation); (c) graft shrinkage occurs mainly in lyophilized and gamma-irradiated grafts (less with cryopreservation); (d) graft extrusion is common but has no clinical/functional implications; (e) overall, MRI is not superior to plain radiograph for graft sizing; (f) graft width size matching is more important than length size matching; (g) height appears to be the most important factor influencing meniscal size; (h) bone fixation better restores contact mechanics than suture fixation, but there are no differences for pullout strength or functional results; and (i) suture fixation has more risk of graft extrusion compared to bone fixation. Systematic review of level II-IV studies, Level IV.

  17. Tratamento fisioterapêutico após reconstrução do ligamento cruzado anterior Physiotherapy after reconstruction of anterior cruciate ligament

    Directory of Open Access Journals (Sweden)

    Maitê Pereira

    2012-12-01

    Full Text Available O objetivo desse estudo foi avaliar se há diferença da evolução na reabilitação dos indivíduos submetidos à reconstrução do LCA através das técnicas osso-tendão patelar-osso ou enxerto quádruplo do semitendíneo e grácil através de uma revisão da literatura. Utilizaram-se as bases de dados eletrônicas: MEDLINE, EMBASE, LILACS, COCHRANE e PEDro. Os critérios de inclusão foram: ensaio clínico randomizado e aleatório com ou sem metanálise; participantes com lesão do LCA associada ou não a lesão meniscal e que foram submetidos à ligamentoplastia e à reabilitação fisioterapêutica; intervenção cirúrgica através das técnicas de reconstrução osso-tendão patelar-osso ou enxerto quádruplo do semitendíneo e grácil; ensaios clínicos que comparem a diferença da evolução na recuperação funcional; estudos publicados nos idiomas: português, inglês e espanhol, no período de 1997 a junho de 2011. Foram encontrados cinco ensaios clínicos que preenchessem os critérios de inclusão. Não foram observadas diferenças clínicas e funcionais entre as técnicas, porém, com recomendação para uma reabilitação menos agressiva e com maior atenção no fortalecimento dos isquiotibiais quando estes são utilizados como enxerto.The purpose of this study was to evaluate the existence of differences in the rehabilitation of patients after ACL reconstruction using bone-patellar tendon-bone graft and the four-strand semitendinosus and gracilis tendon grafts, through a literature revision. The researched databases were MEDLINE, EMBASE, LILACS, COCHRANE and PEDro. The inclusion criteria were published studies with methodology draw from randomized clinical trials with or without meta-analysis, individuals with ACL injury, associated or not to meniscal injury, submitted to ligamentoplasty using the bone-patellar tendon-bone graft and the four-strand semitendinosus and gracilis tendon grafts and physiotherapy; clinical trials

  18. Advances in radiation grafting

    International Nuclear Information System (INIS)

    Hegazy, El-Sayed A.; AbdEl-Rehim, H.A.; Kamal, H.; Kandeel, K.A.

    2001-01-01

    Graft copolymerization is an attractive means for modifying base polymers because grafting frequently results in the superposition of properties relating to the backbone and pendent chains. Among the various methods for initiating the grafting reaction, ionizing radiation is the cleanest and most versatile method of grafting available. Ion-exchange membranes play an important role in modern technology, especially in separation and purification of materials. The search for improved membrane composition has considered almost every available polymeric material because of its great practical importance. Grafting of polymers with a mixture of monomers is important since different types of chains containing different functional groups are included. A great deal is focused on the waste treatment of heavy and toxic metals from wastewater because of the severe problems of environmental pollution. Functionalized polymers suitable for metal adsorption with their reactive functional groups such as carboxylic and pyridine groups suitable for waste treatment were prepared by radiation grafting method. More reactive chelating groups were further introduced to the grafted copolymer through its functional groups by chemical treatments with suitable reagents. The advances of radiation grafting and possible uses are briefly discussed

  19. Calcar bone graft

    Energy Technology Data Exchange (ETDEWEB)

    Bargar, W.L.; Paul, H.A.; Merritt, K.; Sharkey, N.

    1986-01-01

    A canine model was developed to investigate the use of an autogeneic iliac bone graft to treat the calcar deficiency commonly found at the time of revision surgery for femoral component loosening. Five large male mixed-breed dogs had bilateral total hip arthroplasty staged at three-month intervals, and were sacrificed at six months. Prior to cementing the femoral component, an experimental calcar defect was made, and a bicortical iliac bone graft was fashioned to fill the defect. Serial roentgenograms showed the grafts had united with no resorption. Technetium-99 bone scans showed more uptake at three months than at six months in the graft region. Disulfine blue injection indicated all grafts were perfused at both three and six months. Thin section histology, fluorochromes, and microradiographs confirmed graft viability in all dogs. Semiquantitative grading of the fluorochromes indicated new bone deposition in 20%-50% of each graft at three months and 50%-80% at six months. Although the calcar bone graft was uniformly successful in this canine study, the clinical application of this technique should be evaluated by long-term results in humans.

  20. Advances in radiation grafting

    Science.gov (United States)

    Hegazy, El-Sayed A.; AbdEl-Rehim, H. A.; Kamal, H.; Kandeel, K. A.

    2001-12-01

    Graft copolymerization is an attractive means for modifying base polymers because grafting frequently results in the superposition of properties relating to the backbone and pendent chains. Among the various methods for initiating the grafting reaction, ionizing radiation is the cleanest and most versatile method of grafting available. Ion-exchange membranes play an important role in modern technology, especially in separation and purification of materials. The search for improved membrane composition has considered almost every available polymeric material because of its great practical importance. Grafting of polymers with a mixture of monomers is important since different types of chains containing different functional groups are included. A great deal is focused on the waste treatment of heavy and toxic metals from wastewater because of the severe problems of environmental pollution. Functionalized polymers suitable for metal adsorption with their reactive functional groups such as carboxylic and pyridine groups suitable for waste treatment were prepared by radiation grafting method. More reactive chelating groups were further introduced to the grafted copolymer through its functional groups by chemical treatments with suitable reagents. The advances of radiation grafting and possible uses are briefly discussed.

  1. Repeated freeze-thaw cycles reduce the survival rate of osteocytes in bone-tendon constructs without affecting the mechanical properties of tendons.

    Science.gov (United States)

    Suto, Kaori; Urabe, Ken; Naruse, Kouji; Uchida, Kentaro; Matsuura, Terumasa; Mikuni-Takagaki, Yuko; Suto, Mitsutoshi; Nemoto, Noriko; Kamiya, Kentaro; Itoman, Moritoshi

    2012-03-01

    Frozen bone-patellar tendon bone allografts are useful in anterior cruciate ligament reconstruction as the freezing procedure kills tissue cells, thereby reducing immunogenicity of the grafts. However, a small portion of cells in human femoral heads treated by standard bone-bank freezing procedures survive, thus limiting the effectiveness of allografts. Here, we characterized the survival rates and mechanisms of cells isolated from rat bones and tendons that were subjected to freeze-thaw treatments, and evaluated the influence of these treatments on the mechanical properties of tendons. After a single freeze-thaw cycle, most cells isolated from frozen bone appeared morphologically as osteocytes and expressed both osteoblast- and osteocyte-related genes. Transmission electron microscopic observation of frozen cells using freeze-substitution revealed that a small number of osteocytes maintained large nuclei with intact double membranes, indicating that these osteocytes in bone matrix were resistant to ice crystal formation. We found that tendon cells were completely killed by a single freeze-thaw cycle, whereas bone cells exhibited a relatively high survival rate, although survival was significantly reduced after three freeze-thaw cycles. In patella tendons, the ultimate stress, Young's modulus, and strain at failure showed no significant differences between untreated tendons and those subjected to five freeze-thaw cycles. In conclusion, we identified that cells surviving after freeze-thaw treatment of rat bones were predominantly osteocytes. We propose that repeated freeze-thaw cycles could be applied for processing bone-tendon constructs prior to grafting as the treatment did not affect the mechanical property of tendons and drastically reduced surviving osteocytes, thereby potentially decreasing allograft immunogenecity.

  2. Analysis of 500 anterior cruciate ligament reconstructions from a private institutional register.

    Directory of Open Access Journals (Sweden)

    Lauro Augusto Costa

    Full Text Available The aims of this study are to describe the epidemiological characteristics of anterior cruciate ligament reconstructions in a private hospital in Brazil and to determine trends in medical practice for comparison with previous studies.We retrospectively reviewed the anterior cruciate ligament institutional register to obtain data from all patients who underwent primary anterior cruciate ligament reconstruction from July 2014 to June 2016. Descriptive statistics were used to summarize the sample. Specific statistical tests were used to assess associations between the meniscal lesion and other variables.During the study period, 72.6% out of 500 patients were male. The mean age at surgery was 35.1 years. The mean age was higher among females than among males (37.3 ± 12.1 vs 34.3 ± 10.8 years. The median time from injury to surgery was 44 days. The most common femoral and tibial fixations used were suspensory fixation (60.8% and interference screw (96%, respectively. The most commonly used graft was hamstring tendon (70.2%, followed by bone-patellar tendon-bone (28.8%. A meniscal lesion was noted in 44.8% of cases. Partial meniscectomy was performed in 69.5% of meniscal lesions, and meniscal repair was performed in 14.1% of lesions. The mean length of hospital stay was 1.4 days. The proportion of men in the group of patients with an associated meniscal lesion was higher than that in the group of patients without a meniscal lesion (p = 0.007.In this study, we identified that the vast majority of surgeries were performed in male patients in all age groups, and patients older than 30 years and with a short time from injury to surgery predominated. Concerning surgical technique, we noted a low rate of meniscal repair and a higher preference for the use of hamstring graft and suspensory fixation on the femoral side.

  3. Bone Graft Alternatives

    Science.gov (United States)

    ... spinal deformity, or who have some types of disc herniations. In certain types of spinal fusion, bone grafts ... Specialist SEARCH Download Brochure ENGLISH Related Treatments Cervical Disc Herniation Fusion Lumbar Disc Herniation {1} ##LOC[OK]## {1} ## ...

  4. Melting graft wound syndrome

    Directory of Open Access Journals (Sweden)

    Shiou-Mei Chen

    2017-09-01

    Full Text Available Melting graft wound syndrome is characterized by progressive epidermal loss from a previously well-taken skin graft, healed burn, or donor site. It may result in considerable morbidity and require prolonged treatment. We report a 23-year-old flame-burned patient with second- to third-degree burns involving more than 70% of the total body surface area, whose condition was complicated with septic shock. The patient presented with erosions and ulcers occurring on previously well-taken skin graft recipient sites over both legs and progressive epidermal loss on donor sites over the back. The patient's presentation was compatible with the diagnosis of melting graft wound syndrome, and we successfully treated the patient with debridement and supportive treatment.

  5. Axillobifemoral bypass grafting

    Directory of Open Access Journals (Sweden)

    Davidović Lazar B.

    2004-01-01

    Full Text Available INTRODUCTION Axillo-femoral bypass (AxF means connecting the axillar and femoral artery with the graft that is placed subcutaneously [1]. Usually, this graft is connected with contralateral femoral artery via one accessory subcutaneous graft, and this connection is known as axillobifemoral bypass (AxFF. This extra-anatomic procedure is an alternative method to the standard reconstruction of aortoiliac region when there are contraindications for general or local reasons. OBJECTIVE The objective of this paper is to show early and late results of AxFF bypass grafting as well as to show the indications for AxFF bypass. METHODS The sample consisted of 37 patients. The procedure was performed in 28 patients who suffered from aortoiliac occlusive disease and who were at high risk due to the comorbidity- in one patient with the rupture of juxtarenal aneurysm of abdominal aorta; in five patients with aortoenteric fistula, in two patients with iatrogenic lesion of abdominal aorta and in one female patient with anus preternaturalis definitivus who was treated for rectovaginal fistula. Donor's right axillary artery was used in 26 cases (70.3%, and donor's left axillary artery was used in 9 cases (29.7%. Dacron graft was used in 34 patients and Polytetrafluo-roethlylene graft was used in three patients. Simultaneously, profundo-plastic was done in four patients and femoro-popliteal bypass was performed in three patients. In five patients who suffered from aortoenteric fistula, simultaneous intervention of gastrointerstinal system has been done, x2 test was used for statistical evaluation and life table method was used for verification of late graft patency. RESULTS The rate of early postoperative mortality was 13.5%. The causes of death were: sepsis -1, MOFS - 3, and infarct myocardium -1. The mean follow up period was 40.1 months, ranging from six months to 17 years. During the follow up period, an early graft thrombosis was identified in two and late graft

  6. Grafts for Ridge Preservation

    Science.gov (United States)

    Jamjoom, Amal; Cohen, Robert E.

    2015-01-01

    Alveolar ridge bone resorption is a biologic phenomenon that occurs following tooth extraction and cannot be prevented. This paper reviews the vertical and horizontal ridge dimensional changes that are associated with tooth extraction. It also provides an overview of the advantages of ridge preservation as well as grafting materials. A Medline search among English language papers was performed in March 2015 using alveolar ridge preservation, ridge augmentation, and various graft types as search terms. Additional papers were considered following the preliminary review of the initial search that were relevant to alveolar ridge preservation. The literature suggests that ridge preservation methods and augmentation techniques are available to minimize and restore available bone. Numerous grafting materials, such as autografts, allografts, xenografts, and alloplasts, currently are used for ridge preservation. Other materials, such as growth factors, also can be used to enhance biologic outcome. PMID:26262646

  7. [Chickenpox, burns and grafts].

    Science.gov (United States)

    Rojas Zegers, J; Fidel Avendaño, L

    1979-01-01

    An outbreak of chickenpox that occurred at the Burns Repair Surgery Unit, Department of Children's Surgery, Hospital R. del Río, between June and November, 1975, is reported. 27 cases of burned children were studied, including analysis of correlations of the stages and outcome of the disease (varicela), the trauma (burns) and the graft (repair surgery). As a result, the authors emphasize the following findings: 1. Burns and their repair are not aggravating factors for varicella. In a small number of cases the exanthema looked more confluent in the graft surgical areas and in the first degree burns healing spontaneously. 2. Usually there was an uneventful outcome of graft repair surgery on a varicella patient, either during the incubation period, the acme or the convalescence. 3. The fact that the outmost intensity of secondary viremia of varicella occurs before the onset of exanthemia, that is, during the late incubation period, is confirmed.

  8. Arteriovenous shunt graft ulceration with sinus and graft epithelialization

    Directory of Open Access Journals (Sweden)

    Pooja Singhal

    2015-03-01

    Full Text Available Arteriovenous fistula and grafts are used as access sites for patients with chronic kidney disease and are prone for complications. Stent grafts are used to treat access site complications. We report a rare and unusual finding of epithelialization of the sinus tract and the lumen of a polytetrafluoroethylene graft, following ulceration of the overlying skin.

  9. Graft nephrectomy: The SGPGI experience

    OpenAIRE

    Nand Kishore Arvind; Aneesh Srivastava; Anant Kumar; Subodh K Das

    2002-01-01

    Background: Graft nephrectomy is often considered a hazardous procedure with high morbidity and occasional mortality, and this may pose a technical challenge. The aim of this study was to evaluate the indications, etiology and complications following graft nephrectomy. Materials and Methods: From 1988 to 2001, among total of 1,019 live related renal transplants carried at our center, 46 underwent graft nephrectomy. Patients were divided into 2 groups depending on timing of graft re-mova...

  10. Haemodynamics in axillobifemoral bypass grafts

    NARCIS (Netherlands)

    C.H. Wittens

    1992-01-01

    textabstractThis thesis is based on four publications on the subject of graft configuration and haemodynamics in axillobifemoral bypass grafts: 1. A clinical evaluation of 17 patients with axillobifemoral bypass graft operations, performed for various indications. Two important observations were

  11. Anterior knee symptoms after double-bundle ACL reconstruction with hamstring tendon autografts: an ultrasonographic and power Doppler investigation.

    Science.gov (United States)

    Kanamoto, Takashi; Tanaka, Yoshinari; Yonetani, Yasukazu; Kita, Keisuke; Amano, Hiroshi; Kusano, Masashi; Hirabayashi, Shinji; Horibe, Shuji

    2015-11-01

    Anterior knee pain related to the donor site is a frequent complication of anterior cruciate ligament reconstruction (ACLR) with bone-patellar tendon-bone autograft tissue. Even when hamstring tendon (HT) grafts are used instead, symptoms such as mild pain and discomfort can still occur. The purpose of this study was to elucidate the pathophysiology of anterior knee symptoms after ACLR with HT autografts. Fifty-seven patients (22 men and 35 women; mean age, 24.7 years) who underwent anatomic double-bundle ACLR with HT autografts were examined 6 months post-operatively. The presence of anterior knee symptoms, anterior knee laxity, range of motion, and muscle strength were assessed. Changes in patellar tendon and infrapatellar fat pad (IFP) morphology and blood flow were also evaluated using ultrasound. Potential variables affecting the presence of anterior knee symptoms were subjected to univariate analysis and multivariate logistic regression analysis to identify independent risk factors. Six months post-operatively, the total incidence of anterior knee symptoms was 56.1 % (32/57). According to univariate analysis, age, quadriceps strength, and increased blood flow in the IFP were significantly associated with the presence of anterior knee symptoms. Multivariate logistic regression analysis revealed that increased blood flow in the IFP was an independent factor for the presence of anterior knee symptoms (odds ratio 5.0; 95 % confidence interval 1.3-19.9). There were no significant findings inside the patellar tendon. Increased blood flow in the IFP was identified as an independent factor for the presence of anterior knee symptoms 6 months after ACLR with HT autografts. The ultrasound evaluation can help to define precisely the origin of anterior knee symptoms after ACLR with HT autografts. Case series with no comparison groups, Level IV.

  12. Acrylonitrile grafted to PVDF

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jin; Eitouni, Hany Basam

    2015-03-31

    PVDF-g-PAN has been synthesized by grafting polyacrylonitrile onto polyvinylidene fluoride using an ATRP/AGET method. The novel polymer is ionically conducive and has much more flexibility than PVDF alone, making it especially useful either as a binder in battery cell electrodes or as a polymer electrolyte in a battery cell.

  13. Aortic Graft Infection Secondary to Iatrogenic Transcolonic Graft Malposition.

    Science.gov (United States)

    Blank, Jacqueline J; Rothstein, Abby E; Lee, Cheong Jun; Malinowski, Michael J; Lewis, Brian D; Ridolfi, Timothy J; Otterson, Mary F

    2018-01-01

    Aortic graft infections are a rare but devastating complication of aortic revascularization. Often infections occur due to contamination at the time of surgery. Iatrogenic misplacement of the limbs of an aortobifemoral graft is exceedingly rare, and principles of evaluation and treatment are not well defined. We report 2 cases of aortobifemoral bypass graft malposition through the colon. Case 1 is a 54-year-old male who underwent aortobifemoral bypass grafting for acute limb ischemia. He had previously undergone a partial sigmoid colectomy for diverticulitis. Approximately 6 months after vascular surgery, he presented with an occult graft infection. Preoperative imaging and intraoperative findings were consistent with graft placement through the sigmoid colon. Case 2 is a 60-year-old male who underwent aortobifemoral bypass grafting due to a nonhealing wound after toe amputation. His postoperative course was complicated by pneumonia, bacteremia thought to be secondary to the pneumonia, general malaise, and persistent fevers. Approximately 10 weeks after the vascular surgery, he presented with imaging and intraoperative findings of graft malposition through the cecum. Aortic graft infection is usually caused by surgical contamination and presents as an indolent infection. Case 1 presented as such; Case 2 presented more acutely. Both grafts were iatrogenically misplaced through the colon at the index operation. The patients underwent extra-anatomic bypass and graft explantation and subsequently recovered.

  14. Periorbital fat grafting.

    Science.gov (United States)

    Massry, Guy G; Azizzadeh, Babak

    2013-02-01

    Periorbital aging is a multifactorial process involving volume loss (bone and soft tissue), tissue decent, and cutaneous degenerative changes. Traditional approaches to surgery on this area of the face have been subtractive in nature, focusing on excision of skin, muscle, and fat. This has frequently led to a gaunt or hollowed postoperative appearance. Contemporary aesthetic eyelid and periorbital rejuvenation has undergone a paradigm shift from an excisionally based surgical approach to one that prioritizes volume preservation and/or augmentation. The development of fat grafting to the eyelids and periorbita has given the eyelid surgeon a viable surgical alternative to prevent postoperative volume depletion, maintain the smooth transition of the lower eyelid to the cheek, and aid in restoring the youthful appearance desired after surgery. This article will focus of periorbital fat grafting and touch upon fat preservation techniques as primary restorative procedures or as surgical adjuncts. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. Vein grafting in fingertip replantations.

    Science.gov (United States)

    Yan, Hede; Jackson, William D; Songcharoen, Somjade; Akdemir, Ovunc; Li, Zhijie; Chen, Xinglong; Jiang, Liangfu; Gao, Weiyang

    2009-01-01

    In this retrospective study, the survival rates of fingertip replantation with and without vein grafting were evaluated along with their postoperative functional and cosmetic results. One hundred twenty-one-fingertip amputations were performed in 103 patients between September 2002 and July 2007. Thirty-four amputated fingertips were replanted without vein grafting, while 87 amputated fingertips were replanted with vein grafting for arterial and/or venous repairs. The overall survival rates of the replantations with and without vein grafting were 90% (78/87) and 85% (29/34), respectively. The survival rates were 88% (36/41) with venous repair, 93% (25/27) with arterial repair, and 89% (17/19) with both. Nineteen patients without vein grafting and 48 patients with vein grafting had a follow-up period of more than one year. Good cosmetic and functional outcomes were observed in both groups of patients. The results show that vein grafting is a reliable technique in fingertip replantations, showing no significant difference (P > 0.05) in survival between those with and without vein grafting. Furthermore, no significant difference (P > 0.05) in survival was found between cases with vein grafts for arterial and/or venous repairs. In fingertip replantations with vein grafting, favorable functional and esthetic results can be achieved without sacrificing replantation survival. (c) 2009 Wiley-Liss, Inc.

  16. Using skeletonised grafts for coronary artery bypass grafting.

    Science.gov (United States)

    Bawany, Faizan Imran; Khan, Muhammad Shahzeb; Khan, Asadullah; Kazi, Abdul Nafey; Naeem, Muhammed

    2014-05-01

    Coronary artery bypass graft surgery relieves angina symptoms and reduces mortality among ischaemic heart disease patients. It remains the gold standard for the treatment of multi-vessel and left main coronary artery disease. It is a well-known fact that internal mammary artery conduits have excellent and long-lasting patency when used for coronary artery bypass grafting. Its supremacy is largely because it prevents atherosclerosis. The old-style internal mammary artery bypass grafting, classically known as pedicle grafting, includes a circular rim of tissue around the graft. Bilateral pedicled internal mammary arteries, especially among diabetic patients, have been reported to cause complications in the sternum like sternal osteomyelitis. In many studies it has been reported that dissection of pedicled internal mammary artery can lead to sternal devascularisation which can lead to higher incidence of infections. Considering the higher incidence of deep sternal infections in patients with double pedicled arterial grafts, dissection of internal mammary artery in skeletonised manner was proposed. In this review, we outline the advantages of skeletonised grafting with respect to incidence of sternal infection, patency rates, blood flow, post-coronary artery bypass graft pain and the length of the graft.

  17. Micrografts: the "super" expansion graft.

    Science.gov (United States)

    Mardovin, W; Miller, S F; Eppinger, M; Finley, R K

    1992-01-01

    A novel technique for producing micronized skin grafts that was introduced in a paper presented at the 1990 ABA meeting was evaluated to quantify maximum expansion. Twenty Sprague-Dawley rats were divided into two groups representing 10:1 and 25:1 expanded micrograft ratios, respectively. Grafted sites in both groups were shown to heal better than those of the control group, and both grafted groups showed comparable healing at day 10.

  18. Environmental application of radiation grafting

    International Nuclear Information System (INIS)

    Tamada, Masao

    2007-01-01

    Adsorbent having high selectivity against a certain metal ion was synthesized by means of radiation-induced graft polymerization for the purpose of environmental application. The resulting adsorbents were utilized for the removal of toxic metal from scallop waste and the collection of uranium from seawater. As a novel application of grafting, the biodegradability of poly-hydroxybutylate was controlled by grafting. The biodegradability could be depressed by the graft chain and then recovered by external stimuli such as thermal and chemical treatments. (author)

  19. Suction blister grafting - Modifications for easy harvesting and grafting

    Directory of Open Access Journals (Sweden)

    2012-01-01

    Full Text Available Suction blister grafting is a simple modality of treatment of patients with resistant and stable vitiligo. But raising the blisters may be time consuming and transferring to the recipient site may be difficult as the graft is ultrathin. By doing some modifications we can make the technique simpler and easier. We can decrease the blister induction time by intradermal injection of saline, exposure to Wood′s lamp, intrablister injection of saline. By these methods we can decrease the blister induction time from 2-3 hrs to 45-90 minutes. After harvesting the graft, it can be transferred to the recipient area by taking the graft on a sterile glass slide, on the gloved finger, rolling the graft over a sterile syringe and then spreading on the recipient area, or taking on the sterile wrapper of paraffin dressing and then placing over the recipient area.

  20. Bone grafting options in children.

    Science.gov (United States)

    Betz, Randal R; Lavelle, William F; Samdani, Amer F

    2010-08-01

    Retrospective review of the literature. To review the current literature as well as recent trends in bone grafting techniques available for children. The currently accepted gold standard in bone grafting for adolescent idiopathic scoliosis (AIS) is autogenous iliac crest. Due to questions concerning complications such as donor site pain, other options have been explored, including various allograft sources, demineralized bone matrix, and bone morphogenetic protein. A review of the current medical literature was completed and additional case examples are presented. A review of the literature reveals that up to 31% of patients have persistent pain at 2 years post surgery when autogenous iliac crest bone graft is harvested. Allograft supplementation of local autograft has been demonstrated in the literature to be as effective as autogenous iliac crest bone grafting in contributing to a successful posterior spinal fusion in patients with AIS. Modern demineralized bone matrix formulations have been found in both animal models as well as in a recent retrospective clinical review to contribute to a successful posterior spinal fusion in AIS. Bone morphogenetic protein has been shown to contribute to a successful posterior spinal fusion in complex pediatric spinal deformity patients. At 2 years follow-up, patients who underwent a posterior instrumented spinal fusion that was not augmented with any bone graft appear to have successful spinal fusions. Although autogenous iliac bone graft remains the benchmark to which bone grafting materials are compared, other options including the placement of no bone graft at all provides similar fusion rates in patients with AIS.

  1. Radiation grafting on natural films

    Science.gov (United States)

    Lacroix, M.; Khan, R.; Senna, M.; Sharmin, N.; Salmieri, S.; Safrany, A.

    2014-01-01

    Different methods of polymer grafting using gamma irradiation are reported in the present study for the preparation of newly functionalized biodegradable films, and some important properties related to their mechanical and barrier properties are described. Biodegradable films composed of zein and poly(vinyl alcohol) (PVA) were gamma-irradiated in presence of different ratios of acrylic acid (AAc) monomer for compatibilization purpose. Resulting grafted films (zein/PVA-g-AAc) had their puncture strength (PS=37-40 N mm-1) and puncture deformation (PD=6.5-9.8 mm) improved for 30% and 50% PVA in blend, with 5% AAc under 20 kGy. Methylcellulose (MC)-based films were irradiated in the presence of 2-hydroxyethyl methacrylate (HEMA) or silane, in order to determine the effect of monomer grafting on the mechanical properties of films. It was found that grafted films (MC-g-HEMA and MC-g-silane) using 35% monomer performed higher mechanical properties with PS values of 282-296 N mm-1 and PD of 5.0-5.5 mm under 10 kGy. Compatibilized polycaprolactone (PCL)/chitosan composites were developed via grafting silane in chitosan films. Resulting trilayer grafted composite film (PCL/chitosan-g-silane/PCL) presented superior tensile strength (TS=22 MPa) via possible improvement of interfacial adhesion (PCL/chitosan) when using 25% silane under 10 kGy. Finally, MC-based films containing crystalline nanocellulose (CNC) as a filling agent were prepared and irradiated in presence of trimethylolpropane trimethacrylate (TMPTMA) as a grafted plasticizer. Grafted films (MC-g-TMPTMA) presented superior mechanical properties with a TS of 47.9 MPa and a tensile modulus (TM) of 1792 MPa, possibly due to high yield formation of radicals to promote TMPTMA grafting during irradiation. The addition of CNC led to an additional improvement of the barrier properties, with a significant 25% reduction of water vapor permeability (WVP) of grafted films.

  2. Graft intolerance syndrome requiring graft nephrectomy after late kidney graft failure: can it be predicted? A retrospective cohort study.

    Science.gov (United States)

    Bunthof, Kim L W; Verhoeks, Carmen M; van den Brand, Jan A J G; Hilbrands, Luuk B

    2018-02-01

    Graft nephrectomy is recommended in case of early graft failure. When the graft fails more than 3-6 months after transplantation, it is current practice to follow a wait-and-see policy. A common indication for graft removal is the graft intolerance syndrome. We aimed to create a risk prediction model for the occurrence of graft intolerance resulting in graft nephrectomy. We collected data of kidney transplantations performed in our center between 1980 and 2010 that failed at least 6 months after transplantation. We evaluated the association between baseline characteristics and the occurrence of graft nephrectomy because of graft intolerance using a competing risk regression model. Prognostic factors were included in a multivariate prediction model. In- and exclusion criteria were met in 288 cases. In 48 patients, the graft was removed because of graft intolerance. Donor age, the number of rejections, and shorter graft survival were predictive factors for graft nephrectomy because of the graft intolerance syndrome. These factors were included in a prediction rule. Using donor age, graft survival, and the number of rejections, clinicians can predict the need for graft nephrectomy with a reasonable accuracy. © 2017 Steunstichting ESOT.

  3. The Effect of Limited Perioperative Nonsteroidal Anti-inflammatory Drugs on Patients Undergoing Anterior Cruciate Ligament Reconstruction.

    Science.gov (United States)

    Soreide, Endre; Granan, Lars-Petter; Hjorthaug, Geir A; Espehaug, Birgitte; Dimmen, Sigbjørn; Nordsletten, Lars

    2016-12-01

    The administration of nonsteroidal anti-inflammatory drugs (NSAIDs) to patients undergoing anterior cruciate ligament reconstruction (ACLR) is controversial because it may impair tissue healing and clinical outcomes. To assess the effect of NSAID administration on patients undergoing ACLR. Cohort study; Level of evidence, 3. Included patients were aged >15 years and were registered in the Norwegian Knee Ligament Registry from 2008 until 2013 after the primary ACLR. Patients with insufficient data regarding administration of NSAIDs and those with associated knee ligament injuries requiring surgical treatment were excluded from this study. Graft survival was estimated using Kaplan-Meier survival curves, and hazard ratios (HRs) for revision were evaluated using Cox regression analysis. Logistic regression analysis was used to calculate the odds ratio (OR) for a Knee Injury and Osteoarthritis Outcome Score (KOOS)-quality of life (QOL) subscale score <44 at 2-year follow-up. A total of 7822 patients were included in the analysis for graft survival and assessment for risk of revision. Of these, 4144 patients were administered NSAIDs postoperatively. The mean duration of follow-up was 2.8 years (range, 0-5.9 years). Administration of NSAIDs did not influence graft survival (P = .568). Adjusted Cox regression analyses demonstrated the same finding regarding risk of revision (HR, 1.0; 95% CI, 0.8-1.3). ACLR using a bone-patellar tendon-bone autograft showed a reduced risk of revision (HR, 0.3; 95% CI, 0.1-0.8) among patients administered NSAIDs. In subgroup analyses of 3144 patients, administration of NSAIDs demonstrated a beneficial effect on the risk of a KOOS-QOL score <44 at 2-year follow-up (OR, 0.8; 95% CI, 0.6-0.9). Administration of NSAIDs to patients after ACLR does not have a negative effect on graft survival, risk of revision, or risk of a KOOS-QOL score <44 at 2-year follow-up. We emphasize using caution when administering NSAIDs by keeping the duration and

  4. Graft nephrectomy: The SGPGI experience

    Directory of Open Access Journals (Sweden)

    Nand Kishore Arvind

    2002-01-01

    Full Text Available Background: Graft nephrectomy is often considered a hazardous procedure with high morbidity and occasional mortality, and this may pose a technical challenge. The aim of this study was to evaluate the indications, etiology and complications following graft nephrectomy. Materials and Methods: From 1988 to 2001, among total of 1,019 live related renal transplants carried at our center, 46 underwent graft nephrectomy. Patients were divided into 2 groups depending on timing of graft re-moval. The early group included 27 patients (within 2 months of transplantation while in late group (graft re-moval after 2 months of transplantation there were 19 patients. The 2 groups were compared in terms of indica-tion, etiology and complications. Results: In early group the indications for graft removal were acute rejection, thrombosis/infarction and hyper-acute rejection, while in late group the indications were pain, hematuria, fever, hypertension and infection along with chronic failure. Overall, the external iliac artery in-jury occurred in I and 4 patients in early and late group respectively. Major blood loss occurred in I and 6 pa-tients in early and late graft removal respectively. There were 2 deaths in early group due to ftdminant pneumoni-tis that progressed to sepsis and disseminated intravascu-lar coagulation. There were 9 major wound infections all in early group except in 2 patients of late group. Respira-tory infections occurred in 14 patients in early group and 1 in late group. In early group patients had CNS compli-cations in form of seizures, clinical depression and delusional psychosis in 12 patients. Conclusions: Our experience highlights the risk in-volved in graft nephrectomies. Severe acute rejection and thrombosis lead to early graft nephrectomies. Pain, hematuria, infection and hypertension in setting of chronic rejection are predominant causes for the delayed graft ne- phrectomies. Early graft nephrectomy, though technically easy, is

  5. Graft union formation in Douglas-fir.

    Science.gov (United States)

    D.L. Copes

    1969-01-01

    Greenhouse-grown Douglas-fir (Pseudotsuga menziesii [Mirb.] Franco) graft unions were examined between 2 and 84 days after grafting. Room temperature was maintained at 60-70 F throughout the growing season. In most respects grafts of Douglas-fir followed development patterns previously reported for spruce and pine grafts, but specific differences...

  6. Grafting compatibility between selected rootstocks and Tanzanian ...

    African Journals Online (AJOL)

    The grafted seedlings with graft union tied using grafting clips were healed in a dark chamber for three days and then in a transparent chamber for three days. The average temperature and relative humidity in both chambers were maintained at 21-30°C and 85-95 %, respectively. The grafted seedlings were hardened for ...

  7. Saphenous vein graft vs. radial artery graft searching for the best second coronary artery bypass graft

    Science.gov (United States)

    Al-Sabti, Hilal Ali; Al Kindi, Adil; Al-Rasadi, Khalid; Banerjee, Yajnavalka; Al-Hashmi, Khamis; Al-Hinai, Ali

    2013-01-01

    Coronary artery bypass grafting (CABG) was first used in the late 1960s. This revolutionary procedure created hope among ischemic heart disease patients. Multiple conduits are used and the golden standard is the left internal mammary artery to the left anterior descending artery. Although all approaches were advocated by doctors, the use of saphenous vein grafts became the leading approach used by the majority of cardiac surgeons in the 1970s. The radial artery graft was introduced at the same time but was not as prevalent due to complications. It was reintroduced into clinical practice in 1989. The procedure was not well received initially but it has since shown superiority in patency as well as long-term survival after CABG. This review provides a summary of characteristics, technical features and patency rates of the radial artery graft in comparison with venous conduits. Current studies and research into radial artery grafts and saphenous vein grafts for CABG are explored. However, more studies are required to verify the various findings of the positive effects of coronary artery bypass grafting with the help of radial arteries on mortality and long-lasting patency. PMID:24198449

  8. [Skin defect coverage with micro skin graft].

    Science.gov (United States)

    Gümüş, Nazim; Kaya, Yalçin; Karakaya, Sadik; Camci, Cemalettin

    2002-04-01

    The aim of this study is to coverage of the large skin defect with microskin graft. The wound coverage of the large skin defect may be difficult with auto skin graft. In these patients, split thickness skin graft may be used in a bloc shape or expanded skin graft shape and a stamp skin graft shape or expanded stamp skin graft shape. On the other hand, split thickness skin graft may be used as a micrograft shape after the mincing process, which reduces of the graft size in a few millimeters. In this study, 6 patients with skin defect was admitted in our clinic, and their skin defect was treated with micro skin graft. Expansion ratio was 1:15. Epithelialization on the wound surface was completed in 4 to 6 weeks and cobblestone appearance was observed after the wound coverage. Skin defect coverage with micrograft is an effective technique like the other skin graft coverage methods.

  9. Synthesis and characterization of polypyrrole grafted chitin

    Science.gov (United States)

    Ramaprasad, A. T.; Latha, D.; Rao, Vijayalakshmi

    2017-05-01

    Synthesis and characterization of chitin grafted with polypyrrole (PPy) is reported in this paper. Chitin is soaked in pyrrole solution of various concentrations for different time intervals and polymerized using ammonium peroxy disulphate (APS) as an initiator. Grafting percentage of polypyrrole onto chitin is calculated from weight of chitin before and after grafting. Grafting of polymer is further verified by dissolution studies. The grafted polymer samples are characterized by FTIR, UV-Vis absorption spectrum, XRD, DSC, TGA, AFM, SEM and conductivity studies.

  10. Bone Grafting: Sourcing, Timing, Strategies, and Alternatives.

    Science.gov (United States)

    Egol, Kenneth A; Nauth, Aaron; Lee, Mark; Pape, Hans-Christoph; Watson, J Tracy; Borrelli, Joseph

    2015-12-01

    Acute fractures, nonunions, and nonunions with bone defects or osteomyelitis often need bone graft to facilitate union. There are several factors to consider when it is determined that a bone graft is needed. These factors include the source of the bone graft (autograft vs. allograft), proper timing for placement of the bone graft, strategies to avoid further complications (particularly in the setting of osteomyelitis), and with the development of a variety of bone graft substitutes, whether alternatives to autograft are available and appropriate for the task at hand. Autograft bone has commonly been referred to as the "gold standard" of bone grafts, against which the efficacy of other grafts has been measured. The best timing for when to place a bone graft or substitute is also somewhat controversial, particularly after an open fracture or a potentially contaminated bed. The treatment of infected nonunions, particularly those that require a graft to facilitate healing, can be quite challenging. Typically, the infection is completely eradicated before placement of a bone graft, but achieving a sterile bed and the timing of a bone graft require strategic thinking and planning. This review outlines the benefits of autografts, the most suitable sites for harvesting bone grafts, the timing of bone graft procedures, the potential risks and benefits of grafting in the face of infection, and the currently available bone graft extenders.

  11. Air Pump-Assisted Graft Centration, Graft Edge Unfolding, and Graft Uncreasing in Young Donor Graft Pre-Descemet Endothelial Keratoplasty.

    Science.gov (United States)

    Jacob, Soosan; Narasimhan, Smita; Agarwal, Amar; Agarwal, Athiya; A I, Saijimol

    2017-08-01

    To assess an air pump-assisted technique for graft centration, graft edge unfolding, and graft uncreasing while performing pre-Descemet endothelial keratoplasty (PDEK) using young donor grafts. Continuous pressurized air infusion was used for graft centration, graft edge unfolding, and graft unwrinkling. Ten eyes of 10 patients underwent PDEK with donors aged below 40 years. In all eyes, the donor scrolled into tight scrolls. In all cases, the air pump-assisted technique was effective in positioning and centering the graft accurately and in straightening infolded graft edges and smoothing out graft creases and wrinkles. Endothelial cell loss was 38.6%. Postoperative best-corrected visual acuity at 6 months was 0.66 ± 0.25 in decimal equivalent. Continuous pressurized air infusion acted as a third hand providing a continuous pressure head that supported the graft and prevented graft dislocation as well as anterior chamber collapse during intraocular maneuvering. Adequate maneuvering space was available in all cases, and bleeding, if any, was tamponaded successfully in all cases. Although very young donor grafts may be used for PDEK, they are difficult to center and unroll completely before floating against host stroma. An air pump-assisted technique using continuous pressurized air infusion allows successful final graft positioning even with very young donor corneas. It thus makes surgery easier as several key steps are made easier to handle. It additionally helps in tamponading hemorrhage during peripheral iridectomy, increasing surgical space, preventing fluctuations in the anterior chamber depth, and promoting graft adherence.

  12. Costal Grafting in Mandibular Reconstruction.

    Science.gov (United States)

    Bachelet, Jean-Thomas; Bourlet, Jerôme; Château, Joseph; Jacquemart, Mathieu; Dufour, Clémence; Mojallal, Ali; Gleizal, Arnaud

    2015-11-01

    Reconstruction of mandibular bone defect is a common indication in craniomaxillofacial surgery, and free fibular flap is the gold standard for this indication. However, there are alternatives; nonvascular bone grafting is one of them, and we present the costal grafting for mandibular reconstruction, a classic technique that is reliable, efficient, and produced less morbidity than the technique of using composite free flaps. A 9-year retrospective review of 54 patients treated surgically for mandibular reconstruction was performed. The criterion mainly analyzed was graft survival. The surgical technique was described in detail. A total of 54 patients with mandibular bone defect were identified. Five symphysis, 46 corpus, and 20 ramus defects were considered. These patients underwent reconstruction by costal grafting, and the engrafting was successful in 92.6% of cases. Dental rehabilitation with dental implants was realized in 70% of cases. The approach described in this article allowed the authors to obtain good results with costal grafting for mandibular reconstruction and dental rehabilitation. Costal grafting is a good alternative for fibula free flap in specific indications. Reconstruction of mandibular bone defect is a common indication in craniomaxillofacial surgery. Since the 1980s, the gold standard for these defects is the use of free fibular flap.(1) In some cases, this technique is contradicted; the surgeon then has several possibilities for the use of free osteomyocutaneous flaps (iliac crest, scapula, and serrato-costal flaps).(2-8).

  13. Primary graft dysfunction.

    Science.gov (United States)

    Suzuki, Yoshikazu; Cantu, Edward; Christie, Jason D

    2013-06-01

    Primary graft dysfunction (PGD) is a syndrome encompassing a spectrum of mild to severe lung injury that occurs within the first 72 hours after lung transplantation. PGD is characterized by pulmonary edema with diffuse alveolar damage that manifests clinically as progressive hypoxemia with radiographic pulmonary infiltrates. In recent years, new knowledge has been generated on risks and mechanisms of PGD. Following ischemia and reperfusion, inflammatory and immunological injury-repair responses appear to be key controlling mechanisms. In addition, PGD has a significant impact on short- and long-term outcomes; therefore, the choice of donor organ is impacted by this potential adverse consequence. Improved methods of reducing PGD risk and efforts to safely expand the pool are being developed. Ex vivo lung perfusion is a strategy that may improve risk assessment and become a promising platform to implement treatment interventions to prevent PGD. This review details recent updates in the epidemiology, pathophysiology, molecular and genetic biomarkers, and state-of-the-art technical developments affecting PGD. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. Radiation grafting on natural films

    International Nuclear Information System (INIS)

    Lacroix, M.; Khan, R.; Senna, M.; Sharmin, N.; Salmieri, S.; Safrany, A.

    2014-01-01

    Different methods of polymer grafting using gamma irradiation are reported in the present study for the preparation of newly functionalized biodegradable films, and some important properties related to their mechanical and barrier properties are described. Biodegradable films composed of zein and poly(vinyl alcohol) (PVA) were gamma-irradiated in presence of different ratios of acrylic acid (AAc) monomer for compatibilization purpose. Resulting grafted films (zein/PVA-g-AAc) had their puncture strength (PS=37–40 N mm −1 ) and puncture deformation (PD=6.5–9.8 mm) improved for 30% and 50% PVA in blend, with 5% AAc under 20 kGy. Methylcellulose (MC)-based films were irradiated in the presence of 2-hydroxyethyl methacrylate (HEMA) or silane, in order to determine the effect of monomer grafting on the mechanical properties of films. It was found that grafted films (MC-g-HEMA and MC-g-silane) using 35% monomer performed higher mechanical properties with PS values of 282–296 N mm −1 and PD of 5.0–5.5 mm under 10 kGy. Compatibilized polycaprolactone (PCL)/chitosan composites were developed via grafting silane in chitosan films. Resulting trilayer grafted composite film (PCL/chitosan-g-silane/PCL) presented superior tensile strength (TS=22 MPa) via possible improvement of interfacial adhesion (PCL/chitosan) when using 25% silane under 10 kGy. Finally, MC-based films containing crystalline nanocellulose (CNC) as a filling agent were prepared and irradiated in presence of trimethylolpropane trimethacrylate (TMPTMA) as a grafted plasticizer. Grafted films (MC-g-TMPTMA) presented superior mechanical properties with a TS of 47.9 MPa and a tensile modulus (TM) of 1792 MPa, possibly due to high yield formation of radicals to promote TMPTMA grafting during irradiation. The addition of CNC led to an additional improvement of the barrier properties, with a significant 25% reduction of water vapor permeability (WVP) of grafted films. - Highlights: • Irradiation of zein

  15. Age-Related Risk Factors for Revision Anterior Cruciate Ligament Reconstruction: A Cohort Study of 21,304 Patients From the Kaiser Permanente Anterior Cruciate Ligament Registry.

    Science.gov (United States)

    Maletis, Gregory B; Chen, Jason; Inacio, Maria C S; Funahashi, Tadashi T

    2016-02-01

    It is not clear whether risk factors for revision anterior cruciate ligament reconstruction (ACLR) are the same throughout patients' lives. To assess (1) the risk of revision ACLR by age and (2) age-specific risk factors for revision ACLR. Cohort study; Level of evidence, 2. A cohort study using patients having undergone primary ACLR who were registered in the Kaiser Permanente ACLR Registry (February 2005 to June 2013) was conducted. Aseptic revision was the main endpoint. Age was evaluated as a risk factor for revision. The cohort was stratified into 4 age groups: 40 years. Graft type, sex, body mass index (BMI), and race were assessed as revision risk factors within each group. Survival analyses were conducted. Of the 21,304 patients evaluated, 7026 (33%) patients were aged 40 years. Allografts were used in 8671 (41%) patients, hamstring autografts in 6823 (32%), and bone-patellar tendon-bone (BPTB) autografts in 5260 (25%). The 5-year revision probability was highest in patients 40 years old (1.9%; 95% CI, 1.3%-2.7%). Compared with patients aged >40 years, the adjusted revision risk for patients aged 35 kg/m(2) (HR, 0.49; 95% CI, 0.34-0.70) compared with those with a BMI <30 kg/m(2), and black patients (HR, 0.55, 95% CI, 0.36-0.85) compared with white patients. Sex, BMI, and race were not associated with the risk of revision in older patients. In patients ≤40 years old, those with allografts had a higher risk of revision than those with BPTB autografts (HR, 2.69, 2.35, and 3.04 for patients aged <21, 21-30, and 31-40 years, respectively). Patients <21 years old with hamstring autografts had a 1.61 times (95% CI, 1.20-2.17) higher risk of revision than did patients with BPTB autografts; these differences were not identified in older patients. Age at the time of ACLR surgery is a strong risk factor for revision ACLR. Other risk factors for revision ACLR, such as graft type, sex, race, and BMI, may vary in strength and significance over a patient's life

  16. Is Quadriceps Tendon Autograft a Better Choice Than Hamstring Autograft for Anterior Cruciate Ligament Reconstruction? A Comparative Study With a Mean Follow-up of 3.6 Years.

    Science.gov (United States)

    Cavaignac, Etienne; Coulin, Benoit; Tscholl, Philippe; Nik Mohd Fatmy, Nik; Duthon, Victoria; Menetrey, Jacques

    2017-05-01

    The quadriceps tendon (QT) autograft is known as an effective graft for anterior cruciate ligament (ACL) reconstruction and shows a similar functional outcome to the bone-patellar tendon-bone (BPTB) in randomized controlled trials, with a lesser incidence of complications. Up until now, only 2 studies have compared QT to hamstring tendon (HT) autograft. The functional outcomes of the QT technique are at least as good as those of the HT technique, with the same morbidity. Cohort study; Level of evidence, 3. Ninety-five patients underwent isolated ACL reconstruction between January 1 and December 31, 2012. Fifty underwent ACL reconstruction with the QT and 45 with the HT. The same surgical technique, fixation method, and postoperative protocol were used in both groups. The following parameters were evaluated: surgical revisions, functional outcome (Lysholm, Knee injury and Osteoarthritis Outcome Score [KOOS], Tegner, subjective International Knee Documentation Committee), joint stability (KT-1000, Lachman, pivot shift), anterior knee pain (Shelbourne-Trumper score), and isokinetic strength. Descriptive statistics are presented for these variables using the Student t test. Eighty-six patients (45 QT, 41 HT) were reviewed with a mean follow-up of 3.6 ± 0.4 years; minimum follow-up was 3 years. There were 4 reoperations in the QT group (including 1 ACL revision) and 3 in the HT group (including 2 ACL revisions) ( P > .05). The Lysholm (89 ± 6.9 vs 83.1 ± 5.3), KOOS Symptoms (90 ± 11.2 vs 81 ± 10.3), and KOOS Sport (82 ± 11.3 vs 67 ± 12.4) scores were significantly better in the QT group than in the HT group. In terms of stability, the mean side-to-side difference was 1.1 ± 0.9 mm for the QT group and 3.1 ± 1.3 mm for the HT group based on KT-1000 measurements ( P < .005). The negative Lachman component was higher in the QT group than in the HT group (90% vs 46%, P < .005). There was a trend for the negative pivot-shift component to be higher in the QT group

  17. Results of Infrainguinal Bypass with a Composite Graft Combining Polytetrafluoroethylene and Vein Graft in Absence of Appropriate Saphenous Vein Graft.

    Science.gov (United States)

    Jin, Myung Jae; Park, Ui Jun; Kim, Hyoung Tae; Roh, Young-Nam

    2017-06-01

    Use of a composite graft combining a polytetrafluoroethylene graft with an autogenous vein is an option for limb salvage in the absence of an adequate single segment vein graft. We aimed to investigate the results of infrainguinal bypass with a composite graft. We retrospectively reviewed 11 infrainguinal arterial bypasses on 11 limbs which underwent surgery from March 2012 to November 2016. Critical limb ischemia was common (63.6%) indication of bypass surgery and most (90.9%) of the patients had history of failed previous treatment including endovascular treatment (36.4%) and bypass surgery (72.7%). At the 2 years after graft implantations, primary patency and amputation-free survival of below-knee bypasses using composite graft were 73% and 76%, respectively. Infrainguinal arterial bypasses with composite graft had an acceptable patency. In patients without other alternative conduits for revascularization, bypass with a composite graft can be an option.

  18. Plant grafting: new mechanisms, evolutionary implications

    Directory of Open Access Journals (Sweden)

    Eliezer E Goldschmidt

    2014-12-01

    Full Text Available Grafting, an old plant propagation practice, is still widely used with fruit trees and in recent decades also with vegetables. Taxonomic proximity is a general prerequisite for successful graft-take and long-term survival of the grafted, composite plant. However, the mechanisms underlying interspecific graft incompatibility are as yet insufficiently understood. Hormonal signals, auxin in particular, are believed to play an important role in the wound healing and vascular regeneration within the graft union zone. Long-distance protein, mRNA and small RNA graft-transmissible signals currently emerge as novel mechanisms which regulate nutritional and developmental root/top relations and may play a pivotal role in grafting physiology. Grafting also has significant pathogenic projections. On one hand, stock to scion mechanical contact enables the spread of diseases, even without a complete graft union. But, on the other hand, grafting onto resistant rootstocks serves as a principal tool in the management of fruit tree plagues and vegetable soil-borne diseases. The ‘graft hybrid’ historic controversy has not yet been resolved. Recent evidence suggests that epigenetic modification of DNA-methylation patterns may account for certain graft-transformation phenomena. Root grafting is a wide spread natural phenomenon; both intraspecific and interspecific root grafts have been recorded. Root grafts have an evolutionary role in the survival of storm-hit forest stands as well as in the spread of devastating diseases. A more fundamental evolutionary role is hinted by recent findings that demonstrate plastid and nuclear genome transfer between distinct Nicotiana species in the graft union zone, within a tissue culture system. This has led to the formation of alloploid cells that, under laboratory conditions, gave rise to a novel, alloploid Nicotiana species, indicating that natural grafts may play a role in plant speciation. under certain circumstances.

  19. Plant grafting: new mechanisms, evolutionary implications.

    Science.gov (United States)

    Goldschmidt, Eliezer E

    2014-01-01

    Grafting, an old plant propagation practice, is still widely used with fruit trees and in recent decades also with vegetables. Taxonomic proximity is a general prerequisite for successful graft-take and long-term survival of the grafted, composite plant. However, the mechanisms underlying interspecific graft incompatibility are as yet insufficiently understood. Hormonal signals, auxin in particular, are believed to play an important role in the wound healing and vascular regeneration within the graft union zone. Incomplete and convoluted vascular connections impede the vital upward and downward whole plant transfer routes. Long-distance protein, mRNA and small RNA graft-transmissible signals currently emerge as novel mechanisms which regulate nutritional and developmental root/top relations and may play a pivotal role in grafting physiology. Grafting also has significant pathogenic projections. On one hand, stock to scion mechanical contact enables the spread of diseases, even without a complete graft union. But, on the other hand, grafting onto resistant rootstocks serves as a principal tool in the management of fruit tree plagues and vegetable soil-borne diseases. The 'graft hybrid' historic controversy has not yet been resolved. Recent evidence suggests that epigenetic modification of DNA-methylation patterns may account for certain graft-transformation phenomena. Root grafting is a wide spread natural phenomenon; both intraspecific and interspecific root grafts have been recorded. Root grafts have an evolutionary role in the survival of storm-hit forest stands as well as in the spread of devastating diseases. A more fundamental evolutionary role is hinted by recent findings that demonstrate plastid and nuclear genome transfer between distinct Nicotiana species in the graft union zone, within a tissue culture system. This has led to the formation of alloploid cells that, under laboratory conditions, gave rise to a novel, alloploid Nicotiana species, indicating

  20. Vascularized osseous graft for scaphoid

    International Nuclear Information System (INIS)

    Mendez Daza, Carlos Hernan; Mathoulin, Cristophe

    2004-01-01

    The most commonly used technique for treatment of pseudo-arthrosis of the scaphoid is osteo-synthesis with Kirschnet wires and cortical sponge grafts. Results reported by different teams using this procedure show no more than 90% osseous consolidation, especially in cases where vascularisation of the proximal fragment of the scaphoid is compromised. Here we present a series of ten cases of pseudo-arthrosis of the scaphoid, treated using a new surgical technique involving a vascularized osseous graft of the distal radius. Using this procedure we obtained 100% consolidation, with no complications either during the procedure or immediately post-operatively. Patients returned to work in week 15 on average. In 4 cases we observed discomfort in the area of the scar, which was successfully treated using local cortisone injection. The results obtained are very similar to those seen in the literature on the different techniques for vascularized osseous grafts for pseudo-arthrosis of the scaphoid

  1. Crosslinked Radiation-Grafted Films

    Energy Technology Data Exchange (ETDEWEB)

    Slaski, M.; Brack, H.P.; Fischer, D. [Zuercher Hochschule Winterthur (Switzerland); Peter, G. [Zuercher Hochschule Winterthur (Switzerland); Wokaun, A.; Scherer, G.G.

    2004-03-01

    Radiation-grafted membranes prepared by using styrene (S) and divinyl benzene (DVB) as graft components and subsequent sulfonation can be applied as solid polymer electrolytes in fuel cells and other electrochemical devices. The use of DVB as crosslinker has an important influence on the ex-situ properties like swelling, ionic resistivity, mechanical properties, surface energy, and oxidative stability. DVB also influences gas crossover, polarization performance, and lifetime in the fuel cell application. In spite of this importance, the actual DVB content and its extent of reaction has not been well investigated. (author)

  2. Reconstruction of mandible with pedicle bone grafts.

    Science.gov (United States)

    Kowalik, S

    1980-02-01

    Three cases of pedicle bone grafts used to reconstruct the mandible are presented. The grafts were taken from the shoulder blade, rib and clavicle. In two patients partial and in one patient total mandibles were reconstructed. Good results were obtained.

  3. Evaluation of Replacement Grafts and Punch Grafts in the Treatment of Vitiligo

    Directory of Open Access Journals (Sweden)

    Singh Ajit Kumar

    1980-01-01

    Full Text Available Thirtycasesof vitiligo eachwithminimum of two lesions undent replacement graft and multiple punch grafts in one lesion each. Complications observed at the recipient site like infection and raised nigosed surface were significantly more in replacement grafts. Hypopigmentation of the graft was significantly more when the disease was progressive.

  4. Graft infections after surgical aortic reconstructions

    NARCIS (Netherlands)

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open

  5. The caudal septum replacement graft.

    Science.gov (United States)

    Foda, Hossam M T

    2008-01-01

    To describe a technique for reconstructing the lost tip support in cases involving caudal septal and premaxillary deficiencies. The study included 120 patients with aesthetic and functional nasal problems resulting from the loss of caudal septal and premaxillary support. An external rhinoplasty approach was performed to reconstruct the lost support using a cartilaginous caudal septum replacement graft and premaxillary augmentation with Mersilene mesh. The majority of cases (75%) involved revisions in patients who had previously undergone 1 or more nasal surgical procedures. A caudal septum replacement graft was combined with premaxillary augmentation in 93 patients (77.5%). The mean follow-up period was 3 years (range, 1-12 years). The technique succeeded in correcting the external nasal deformities in all patients and resulted in a significant improvement in breathing in 74 patients (86%) with preoperative nasal obstruction. There were no cases of infection, displacement, or extrusion. The caudal septum replacement graft proved to be very effective in restoring the lost tip support in patients with caudal septal deficiency. Combining the graft with premaxillary augmentation using Mersilene mesh helped increase support and stability over long-term follow-up.

  6. Endovascular stent grafting: a review

    International Nuclear Information System (INIS)

    Kribs, S.

    2001-01-01

    Endovascular stent grafts are intravascular devices composed of surgical graft material and a metallic frame, (Fig. 1). Their main application has been to treat aneurysms, but they have been used in vascular trauma and are being investigated for use in occlusive disease. Their advantage in treating aneurysms over conventional surgical treatment is that they are loaded into relatively small delivery systems (Fig. 2) and can be introduced to the area of interest from a remote site - usually the femoral artery. This avoids the morbidity of surgical exposure in difficult sites, such as the thoracic aorta, and lessens the cardiovascular stress to patients by eliminating the need to surgically cross-clamp the vessel being treated. The first description of abdominal aortic aneurysm exclusion by an endovascular stent graft was provided by Parodi and colleagues in 1991. Much of the early clinical experience in endovascular stent grafting was obtained from centres in Australia and Europe, and they are now reporting midterm follow-up data. There are now many centres in Canada and the United States involved in endovascular research and practice. (author)

  7. SOME TECHNIQUES IN CORNEAL GRAFTING

    African Journals Online (AJOL)

    1971-04-10

    Apr 10, 1971 ... simulate as nearly as possible the intra-ocular tension of the recipient. In this manner the apposition of the graft to the host cornea is as satisfactory as .... rected to 6/9 in spite of distortion and encroachment of the fibrotic process on the pupillary area. There has been no recurrence and inspection shows.

  8. Factors affecting anterior knee pain following anatomic double-bundle anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Niki, Yasuo; Hakozaki, Akihiro; Iwamoto, Wataru; Kanagawa, Hiroya; Matsumoto, Hideo; Toyama, Yoshiaki; Suda, Yasunori

    2012-08-01

    The purpose of this study was to evaluate the prevalence of anterior knee pain in anatomic double-bundle anterior cruciate ligament (ACL) reconstruction and to identify critical factors affecting postoperative anterior knee pain development. Subjects comprised 171 patients (171 knees) who underwent anatomic double-bundle ACL reconstruction with a follow-up period of ≥2 years. The procedure used bone-patellar tendon-bone plus gracilis tendon (BTB-G) in 56 knees, semitendinosus tendon (ST) in 71 knees, and ST-G in 44 knees. Clinical results and prevalence and severity of anterior knee pain were assessed at 3 months and 2 years postoperatively. Clinical variables influencing anterior knee pain development at each postoperative period were subjected to univariate analysis, followed by logistic regression analysis to identify risk factors for anterior knee pain. Overall prevalences of anterior knee pain at 3 months and 2 years postoperatively were 42.0 and 11.1%, respectively. Use of BTB-G graft represented the highest prevalence of anterior knee pain between the 3 different grafts (P = 0.001); however, this statistical significance disappeared at 2 years postoperatively. Prevalence of postoperative extension deficit was significantly higher in anterior knee pain-positive cohort than in anterior knee pain-negative cohort at 3 months postoperatively. Level of quadriceps strength was significantly lower, and Lysholm score was significantly worse in anterior knee pain-positive cohort than in anterior knee pain-negative cohort at 2 years postoperatively. According to logistic regression analysis, knee extension deficit was a predisposing factor for the development of anterior knee pain at 3 months postoperatively (odds ratio, 2.76; P = 0.004); however, there was no significant predisposing factor for anterior knee pain at 2 years postoperatively. Knee extension deficit was an important predisposing factor for postoperative anterior knee pain in the early

  9. Torsional stability of interference screws derived from bovine bone - a biomechanical study

    Directory of Open Access Journals (Sweden)

    Schmitt Jan

    2010-05-01

    Full Text Available Abstract Background In the present biomechanical study, the torsional stability of different interference screws, made of bovine bone, was tested. Interference screws derived from bovine bone are a possible biological alternative to conventional metallic or bioabsorbable polymer interference screws. Methods In the first part of the study we compared the torsional stability of self-made 8 mm Interference screws (BC and a commercial 8 mm interference screw (Tutofix®. Furthermore, we compared the torsional strength of BC screws with different diameters. For screwing in, a hexagon head and an octagon head were tested. Maximum breaking torques in polymethyl methacrylate resin were recorded by means of an electronic torque screw driver. In the second part of the study the tibial part of a bone-patellar tendon-bone graft was fixed in porcine test specimens using an 8 mm BC screw and the maximum insertion torques were recorded. Each interference screw type was tested 5 times. Results There was no statistically significant difference between the different 8 mm interference screws (p = 0.121. Pairwise comparisons did not reveal statistically significant differences, either. It was demonstrated for the BC screws, that a larger screw diameter significantly leads to higher torsional stability (p = 9.779 × 10-5. Pairwise comparisons showed a significantly lower torsional stability for the 7 mm BC screw than for the 8 mm BC screw (p = 0.0079 and the 9 mm BC screw (p = 0.0079. Statistically significant differences between the 8 mm and the 9 mm BC screw could not be found (p = 0.15. During screwing into the tibial graft channel of the porcine specimens, insertion torques between 0.5 Nm and 3.2 Nm were recorded. In one case the hexagon head of a BC screw broke off during the last turn. Conclusions The BC screws show comparable torsional stability to Tutofix® interference screws. As expected the torsional strength of the screws increases significantly with the

  10. Torsional stability of interference screws derived from bovine bone - a biomechanical study

    Science.gov (United States)

    2010-01-01

    Background In the present biomechanical study, the torsional stability of different interference screws, made of bovine bone, was tested. Interference screws derived from bovine bone are a possible biological alternative to conventional metallic or bioabsorbable polymer interference screws. Methods In the first part of the study we compared the torsional stability of self-made 8 mm Interference screws (BC) and a commercial 8 mm interference screw (Tutofix®). Furthermore, we compared the torsional strength of BC screws with different diameters. For screwing in, a hexagon head and an octagon head were tested. Maximum breaking torques in polymethyl methacrylate resin were recorded by means of an electronic torque screw driver. In the second part of the study the tibial part of a bone-patellar tendon-bone graft was fixed in porcine test specimens using an 8 mm BC screw and the maximum insertion torques were recorded. Each interference screw type was tested 5 times. Results There was no statistically significant difference between the different 8 mm interference screws (p = 0.121). Pairwise comparisons did not reveal statistically significant differences, either. It was demonstrated for the BC screws, that a larger screw diameter significantly leads to higher torsional stability (p = 9.779 × 10-5). Pairwise comparisons showed a significantly lower torsional stability for the 7 mm BC screw than for the 8 mm BC screw (p = 0.0079) and the 9 mm BC screw (p = 0.0079). Statistically significant differences between the 8 mm and the 9 mm BC screw could not be found (p = 0.15). During screwing into the tibial graft channel of the porcine specimens, insertion torques between 0.5 Nm and 3.2 Nm were recorded. In one case the hexagon head of a BC screw broke off during the last turn. Conclusions The BC screws show comparable torsional stability to Tutofix® interference screws. As expected the torsional strength of the screws increases significantly with the diameter. The safety

  11. Radiochemical grafting of acryonitrile on polystyrene

    International Nuclear Information System (INIS)

    Jendrychowska-Bonamour, A.M.; Michot, C.

    1977-01-01

    Polystyrene polyacrylonitrile copolymers have been prepared by the direct radio-induced grafting method. The reaction has been carried out in a gel of polystyrene swollen by the monomer. The ungrafted polystyrene has been extracted by toluene. It has been possible to separate grafted copolymers from homopolymer traces, despite the very strong dipole-dipole interactions exhibited in solution between polyacrylonitrile chains; afterwards these grafted copolymers were fractionated by composition. The limits of solubility and the glass transition temperatures of the grafted copolymers have been determined. The properties of grafted copolymers have been compared with those of block polyacrylonitrile copolymers. (authors)

  12. Homogeneous cation exchange membrane by radiation grafting

    International Nuclear Information System (INIS)

    Kolhe, Shailesh M.; G, Agathian; Ashok Kumar

    2001-01-01

    Preparation of a strong cation exchange membrane by radiation grafting of styrene on to polyethylene (LDPE) film by mutual irradiation technique in the presence of air followed by sulfonation is described. The grafting has been carried out in the presence of air and without any additive. Low dose rate has been seen to facilitate the grafting. Further higher the grafting percentage more is the exchange capacity. The addition of a swelling agent during the sulfonation helped in achieving the high exchange capacity. The TGA-MASS analysis confirmed the grafting and the sulfonation. (author)

  13. Dynamics of bone graft healing around implants

    Directory of Open Access Journals (Sweden)

    Narayan Venkataraman

    2015-01-01

    A few questions arise pertaining to the use of bone grafts along with implants are whether these are successful in approximation with implant. Do they accelerate bone regeneration? Are all defects ultimately regenerated with new viable bone? Is the bone graft completely resorbed or integrated in new bone? Does the implant surface characteristic positively affect osseointegration when used with a bone graft? What type of graft and implant surface can be used that will have a positive effect on the healing type and time? Finally, what are the dynamics of bone graft healing around an implant? This review discusses the cellular and molecular mechanisms of bone graft healing in general and in vicinity of another foreign, avascular body, namely the implant surface, and further, the role of bone grafts in osseointegration and/or clinical success of the implants.

  14. Septal graft in laryngeal reconstruction

    International Nuclear Information System (INIS)

    Bahannan, Abdulrahman; Slavicek, A.; Taudy, M.; Chovanec, M.

    2006-01-01

    A 62-year-old woman presented with symptoms of dyspnea. Ultrasonography and computed tomography examinations revealed mass extending from the cricoid cartilage to the left lobe of thyroid gland and thyroid cartilage. Cytology revealed possibility of cartilaginous origin, which was proven to be chondrosarcoma (Grade 1) from the biopsy specimen obtained during panendosopy. She underwent one stage radical resection and immediate reconstruction of laryngeal skeleton defect by mucocartilaginous graft from the nasal septum. Her postoperative course was optimal with preservation of the laryngeal functions. Twenty-eight months postoperatively, she had to undergo total laryngectomy as a salvage procedure for the advanced local recurrence. We report on the relatively easy technique for functional reconstruction of the large laryngeal defect with the employment cartilage graft from the nasal septum. (author)

  15. Graft versus host disease prophylaxis

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Graft versus host disease prophylaxis. Cyclosporine -2.5mg/KG IV over 4 hrs q12h. - 5mg/Kg BD orally for 6 months - taper- stop at one year if no GVHD. Methotrexate :INITIAL. day +1- 15mg/m2; day + 3, 6, 11- 10 mg/m2; :CURRENT; day +1-10mg/m2; day + 3,6,11 ...

  16. Evaluation of early coronary graft patency after coronary artery bypass graft surgery using multislice computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Raissi Kamal

    2009-12-01

    Full Text Available Abstract Background Coronary artery bypass graft (CABG surgery is the standard of care in the treatment of advanced coronary artery disease, and its long-term results are affected by the failure of bypass grafts. The aim of the present study was to evaluate the early patency rate in coronary bypass grafts. Methods A total of 107 consecutive patients who underwent CABG were included in this study. Early graft patency was evaluated via computed tomography (CT angiography in the first week after surgery. Results There were a total of 366 grafts, comprised of 250 venous grafts and 116 arterial grafts. Multi-slice CT detected acute graft occlusions in 32 (8.7% of all the grafts, including 26 (10% of the 250 venous grafts and 6 (5% of the 116 arterial grafts. The patency rates obtained were 97.3% for the left internal mammary (IMA grafts, 50% for the radial artery grafts, and 50% for the right IMA grafts. Additionally, 107 (96.4% grafts to the left anterior descending artery (LAD were classified as patent, whereas 1 (30% of the 3 grafts in the left circumflex (LCX region and 1 (50% of the 2 grafts in the right coronary artery (RCA territory were found to be occluded. In the venous category, 8 (13.7% of the 58 grafts to LAD were found to be occluded. In the LCX region, 9 (8.5% of the 106 grafts were classified as occluded, while the remaining 97 (91.5% grafts were patent. The venous grafts to RCA were occluded in 9 (10.4% of the 86 grafts. Amongst the multiple preoperative, intraoperative, and postoperative factors, pump time was significantly longer in the patients with occluded grafts than in those with patent grafts (P = 0.04. Conclusion The IMA grafts had the highest early patency rate amongst the coronary bypass grafts. However, the other arterial grafts were associated with a high rate of acute occlusions.

  17. Fixation of tibial plateau fractures with synthetic bone graft versus natural bone graft: a comparison study.

    LENUS (Irish Health Repository)

    Ong, J C Y

    2012-06-01

    The goal of this study was to determine differences in fracture stability and functional outcome between synthetic bone graft and natural bone graft with internal fixation of tibia plateau metaphyseal defects.

  18. Novel expansion techniques for skin grafts

    Science.gov (United States)

    Kadam, Dinesh

    2016-01-01

    The quest for skin expansion is not restricted to cover a large area alone, but to produce acceptable uniform surfaces, robust engraftment to withstand mechanical shear and infection, with a minimal donor morbidity. Ease of the technique, shorter healing period and reproducible results are essential parameters to adopt novel techniques. Significant advances seen in four fronts of autologous grafting are: (1) Dermal–epidermal graft expansion techniques, (2) epidermal graft harvests technique, (3) melanocyte-rich basal cell therapy for vitiligo and (4) robust and faster autologous cell cultures. Meek's original concept that the sum of perimeter of smaller grafts is larger than the harvested graft, and smaller the graft size, the greater is the potential for regeneration is witnessed in newer modification. Further, as graft size becomes smaller or minced, these micrografts can survive on the wound bed exudate irrespective of their dermal orientation. Expansion produced by 4 mm × 4 mm sized Meek micrografts is 10-folds, similarly 0.8 mm × 0.8 mm size micrografts produce 100-fold expansion, which becomes 700-fold with pixel grafts of 0.3 mm × 0.3 mm size. Fractional skin harvest is another new technique with 700 μ size full thickness graft. These provide instant autologous non-cultured graft to cover extensive areas with similar quality of engraftment surface as split skin grafts. Newer tools for epidermal blister graft harvest quickly, with uniform size to produce 7-fold expansions with reproducible results. In addition, donor area heals faster with minimal scar. Melanocyte-rich cell suspension is utilised in vitiligo surgery tapping the potential of hair root melanocytes. Further advances in the cell culture to reduce the cultivation time and provide stronger epidermal sheets with dermal carrier are seen in trials. PMID:27274117

  19. Graft infections after surgical aortic reconstructions

    OpenAIRE

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open surgical reconstructions as first line of treatment for aorto-iliac diseases. Nowadays, open reconstructions are primarily reserved for patients unsuitable for endovascular reconstructions or for redo ...

  20. Outcomes of AV Fistulas and AV Grafts after Interventional Stent-Graft Deployment in Haemodialysis Patients.

    Science.gov (United States)

    Schmelter, Christopher; Raab, Udo; Lazarus, Friedrich; Ruppert, Volker; Vorwerk, Dierk

    2015-08-01

    The study was designed to assess outcomes of arteriovenous (AV) accesses after interventional stent-graft deployment in haemodialysis patients. 63 haemodialysis patients with 66 AV fistulas and AV grafts were treated by interventional stent-graft deployment from 2006 to 2012 at our hospital. Data of these patients were retrospectively analysed for location of deployed stent-grafts, occurrence and location of (re-)stenosis and (re-)thrombosis. Complex stenosis was the most frequent indication for stent-graft deployment (45.5%), followed by complications of angioplasty with vessel rupture or dissection (31.8%). A high rate of procedural success was achieved (98.5%). The most frequent location of the deployed stent-graft was the draining vein (66.7%). Stent-graft deployment was more frequent in AV grafts than in AV fistulas. Primary patency was 45.5% at 6 month, 31.3% at 12 month and 19.2% at 24 month. Primary patency was significantly better for AV fistulas than for AV grafts with deployed stent-grafts. Patency of the deployed stent-graft was much better than overall AV access primary patency with deployed stent-graft. Re-stenosis with thrombosis was the most frequent indication for re-intervention. Most frequent location of re-stenosis was the draining vein (37.1%), followed by stenosis at the AV access (29.5%) and the deployed stent-graft (23.5%). Re-stenosis and re-thrombosis remain frequent in AV fistulas and AV grafts in haemodialysis patients despite stent-graft deployment. Re-stenosis of the deployed stent-graft is, only in the minority of the cases, responsible for AV access dysfunction.

  1. Outcomes of AV Fistulas and AV Grafts after Interventional Stent-Graft Deployment in Haemodialysis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Schmelter, Christopher, E-mail: christopher.schmelter@klinikum-ingolstadt.de; Raab, Udo, E-mail: udo.raab@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany); Lazarus, Friedrich, E-mail: friedrich.lazarus@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Nephrology (Germany); Ruppert, Volker, E-mail: volker.ruppert@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Vascular Surgery (Germany); Vorwerk, Dierk, E-mail: dierk.vorwerk@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany)

    2015-08-15

    PurposeThe study was designed to assess outcomes of arteriovenous (AV) accesses after interventional stent-graft deployment in haemodialysis patients.Materials and Methods63 haemodialysis patients with 66 AV fistulas and AV grafts were treated by interventional stent-graft deployment from 2006 to 2012 at our hospital. Data of these patients were retrospectively analysed for location of deployed stent-grafts, occurrence and location of (re-)stenosis and (re-)thrombosis. Complex stenosis was the most frequent indication for stent-graft deployment (45.5 %), followed by complications of angioplasty with vessel rupture or dissection (31.8 %).ResultsA high rate of procedural success was achieved (98.5 %). The most frequent location of the deployed stent-graft was the draining vein (66.7 %). Stent-graft deployment was more frequent in AV grafts than in AV fistulas. Primary patency was 45.5 % at 6 month, 31.3 % at 12 month and 19.2 % at 24 month. Primary patency was significantly better for AV fistulas than for AV grafts with deployed stent-grafts. Patency of the deployed stent-graft was much better than overall AV access primary patency with deployed stent-graft. Re-stenosis with thrombosis was the most frequent indication for re-intervention. Most frequent location of re-stenosis was the draining vein (37.1 %), followed by stenosis at the AV access (29.5 %) and the deployed stent-graft (23.5 %).ConclusionRe-stenosis and re-thrombosis remain frequent in AV fistulas and AV grafts in haemodialysis patients despite stent-graft deployment. Re-stenosis of the deployed stent-graft is, only in the minority of the cases, responsible for AV access dysfunction.

  2. The autologus graft of epithelial tissue culture

    Directory of Open Access Journals (Sweden)

    Minaee B

    1999-08-01

    Full Text Available With the intention of research about culture and autologus graft of epithelial tissue we used 4 french Albino Rabbits with an average age of 2 months. After reproduction on the support in EMEM (Eagle's Minimum Essential Medium we used this for graft after 4 weeks. This region which grafted total replaced. After fixation of this sample and passing them through various process, histological sections were prepared. These sections were stained with H & E and masson's trichrome and studied by light microscope. We succeeded in graft. We hope in the near future by using the method of epithelium tissue culture improving to treat burned patients.

  3. Autogenous femoral head as grafting material for mandibular augmentation

    NARCIS (Netherlands)

    Vos, M. D.; Raghoebar, G. M.; van der Wal, J. E.; Kalk, W. W. I.; Vissink, A.

    2009-01-01

    Bone grafting is commonly used for augmentation of the atrophic edentulous maxilla and mandible. Although bone substitutes and allogeneic frozen bone grafts have been applied successfully, fresh autogenous bone grafts remain the 'gold standard' in maxillofacial reconstructive surgery. A disadvantage

  4. Industrial application of electron beams for grafting and vulcanization

    International Nuclear Information System (INIS)

    Keizo Makuuchi

    1994-01-01

    The topics discussed are radiation graft polymerization; industrial application of radiation grafting - ion exchange membrane for a battery separator, ammonia adsorbent, non-flammable PE (polyethylene) foam; R and D on radiation grafting, radiation vulcanization of natural rubber

  5. Improvement of polymer stability by radiation grafting

    International Nuclear Information System (INIS)

    Ranogajec, F.; Mlinac-Misak, M.

    1999-01-01

    Losses of the stabilizer due to extractability or volatility immediately affect ultimate performance of polymer product. A new approach to increase the persistence of the stabilizer in the final product is to chemically bind it to the polymer backbone. Radiation grafting or crosslinking could be an efficient method for this, when the stabilizer is polymerizable. By a mutual gamma irradiation method, photoprotector 2-hydroxy-4-(3-methacryloxy-2- hydroxy-propoxy) benzophenone (HMB) has been readily grafted to low density polyethylene (LDPE) in benzene, tetrahydrofuran and methanol solution, respectively. Surface grafting occurs in a methanol solution of stabilizer, while in benzene and tetrahydrofuran solutions of stabilizer, grafting proceeds more or less in the inner parts of the polymeric film as well. The grafted LDPE film in methanol and tetrahydrofuran (containing 1 w/w % of grafted HMB), 1 w/w % blended HMB with LDPE and nongrafted LDPE film, were all exposed to accelerated aging and natural weathering and their spectral changes, expressed by the carbonyl index, were then compared. The change of elongation at break and tensile strength were measured in the course of aging. UV stability tests on aged films and change in mechanical properties indicate a pronounced protective effect achieved by grafted stabilizer. Grafting in methanol solution appears to be an efficient photostabilization treatment and the most economical with respect to the consumption of monomer, the grafting yield being less than 0.5%. Surface grafting is an efficient photostabilization method since grafted stabilizer is chemically bound to a polymeric surface and in this way the problem of evaporation of blended stabilizers during the prolonged use of polymeric materials is eliminated. (author)

  6. Influence of ischemia before vein grafting on early hyperplasia of the graft and the dynamic changes of the intima after grafting

    Directory of Open Access Journals (Sweden)

    Zou RongJiang

    2012-09-01

    Full Text Available Abstract Background To investigate both the influence of ischemia before grafting on early hyperplasia of the vein grafts, and the dynamic changes of the intima after grafting in a rabbit model of vein graft disease. Methods We performed paired vein graft experiments under different ischemic conditions (15 vs. 60 min; 15 vs. 90 min in the neck of the rabbits and compared the differences between the grafts. Clopidogrel, an anti-platelet agent, was administered before and after surgery. Twenty-eight days after the grafting procedure, the veins were evaluated microscopically. The dynamic changes of the intima after grafting were evaluated by scanning electron microscopy over time. Results The vein grafts subjected to 60- or 90-min ischemia exhibited no differences compared to those subjected to 15-min ischemia in terms of the mean thickness of the intimal, medial, and adventitial layers of the graft. Similarly, there was no difference in the Ki-67 labeling index (proliferation marker between the vein grafts. Vein grafts with 15-min ischemia lost endothelial cells (ECs but healed by 3 days post graft, whereas vein grafts with 90-min ischemia suffered serious EC loss, which was restored with new ECs during days 2 to 14 post graft. Conclusions Ninety-minute ischemia before vein grafting can cause serious EC loss, but does not increase early intimal hyperplasia when clopidogrel is administered. Protecting the vein from ischemia and reperfusion injury preserves ECs.

  7. Spreader Grafts in Functional Rhinoplasty.

    Science.gov (United States)

    Kim, Leslie; Papel, Ira D

    2016-02-01

    Management of the middle vault is paramount to achieving optimal aesthetic and functional outcomes in rhinoplasty. The ideal treatment for middle vault complications, such as internal nasal valve collapse, inverted-V deformity, and middle vault dorsal asymmetry, is prevention. Risk factors for middle vault problems in rhinoplasty that may be identified in preoperative consultation include short nasal bones, long and weak upper lateral cartilages, thin skin, previous trauma or surgery, preoperative positive Cottle maneuver, tension nose deformity, and anteriorly positioned inferior turbinates. When any of these risk factors are identified, preventive measures should be pursued. These include preservation of middle vault support structures, judicious resection in dorsal hump reduction, use of conservative osteotomies, and reconstruction of the cartilaginous middle vault with structural grafting. Spreader grafts have become the workhorse in middle vault reconstruction. They are invaluable in restoring nasal dorsal aesthetic lines, repairing or maintaining the internal nasal valve, and buttressing a corrected crooked nose. Functional and aesthetic problems related to the middle nasal vault are among the most common reasons for patients seeking revision rhinoplasty. Although complications in rhinoplasty are inevitable, underlying their etiology and instituting prophylactic treatment can significantly help reduce their occurrence. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  8. [Autologous fat grafting and rhinoplasty].

    Science.gov (United States)

    Nguyen, P S; Baptista, C; Casanova, D; Bardot, J; Magalon, G

    2014-12-01

    Revision rhinoplasty can be very challenging especially in cases of thin skin. Autologous fat graft is utilized in numerous applications in plastic surgery; however, its use relative to the nasal region remains uncommon. Adipose tissue, by virtue of its volumetric qualities and its action on skin trophicity, can be considered to be a gold standard implant. From 2006 until 2012, we have treated patients by lipofilling in order to correct sequelae of rhinoplasty. The mean quantity of adipose tissue injected was 2.1cm(3) depending on the importance of the deformity and the area of injection: irregularity of the nasal dorsum, visible lateral osteotomies, saddle nose. Following the course of our practice, we conceived micro-cannulas that allow a much greater accuracy in the placement of the graft and enable to perform interventions under local anesthesia. These non-traumatic micro-cannulas do not cause post-operative ecchymosis and swelling which shorten the recovery time for the patient. On patients who have undergone multiple operations, lipofilling can be a simple and reliable alternative to correct imperfections that may take place after a rhinoplasty. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  9. Grafted hydroxypropyl guargum: Development, characterization and ...

    Indian Academy of Sciences (India)

    Synthesis of hydroxypropyl guargum--polyacrylamide was carried out by ceric ion induced redox polymerization technique at 28 ± 1°C. The graft copolymer was characterized by IR and thermal analysis. The flocculation performance of graft copolymer was tested in 1 wt% coal suspension.

  10. Grafted hydroxypropyl guargum: Development, characterization and ...

    Indian Academy of Sciences (India)

    Unknown

    Flocculation tests of coal fine suspension were carried out on column settling method and standard flocculation jar apparatus (supplied by M.B. Instruments, India). 3. Results and discussion. In the present investigation, two series of graft copoly- mers have been synthesized by grafting PAM onto HPG using ceric ion initiator, ...

  11. A novel initiating system for wool grafting

    Directory of Open Access Journals (Sweden)

    Magdy Kandil Zahran

    2016-05-01

    Full Text Available This paper describes a new method for the grafting of methacrylic acid (MAA and other acrylic monomers onto wool fabric in aqueous medium. The novelty principally concerns the chemical approach of the redox grafting reaction that was carried out in the presence of sodium perborate (SPB initiator. Before the grafting reaction was started, the wool fabric was treated first with a freshly prepared ferrous ammonium sulfate (FAS solution. The so-treated fabric formed, with SPB, an efficacious redox system capable of initiating grafting of methacrylic acid (MAA and other acrylic monomers onto the wool fabric. The effect of the polymerization conditions on the polymer criteria, namely, graft yield (%GY, homopolymer (%HP, total conversion (%TC, and grafting efficiency (%GE, was studied. These polymer criteria were found to depend spaciously upon concentrations of the Fe2+ ion (activator, SPB (initiator, and MAA, pH of the polymerization medium, duration and temperature of polymerization. The graft copolymerization reaction has also been carried out in the presence of polymerization activators (e.g. reductant transition metal ions and an inhibitor (e.g. hydroquinone. A suitable mechanism for the grafting processes has been suggested, in accordance with the experimental results.

  12. Oral mucosa grafts for urethral reconstruction

    African Journals Online (AJOL)

    Background: Urethral reconstruction has continued to present formidable and enormous challenges for urologic, ... reports reveal that split and full thickness skin grafts from the scrotum, penis, extragenital sites (ureter, saphenous ... Unlike other tissues, oral mucosa grafts are flexible, easy to harvest and trim and have.

  13. Graft loss after pediatric liver transplantation

    NARCIS (Netherlands)

    Sieders, E; Peeters, PMJG; TenVergert, EM; de Jong, KP; Porte, RJ; Zwaveling, JH; Bijleveld, CMA; Gouw, ASH; Slooff, MJH

    Objective To describe the epidemiology and causes of graft loss after pediatric liver transplantation and to identify risk factors. Summary Background Data Graft failure after transplantation remains an important problem. It results in patient death or retransplantation, resulting in lower survival

  14. Graft polymerization of glycidylmethacrylate onto coralline hydroxyapatite.

    Science.gov (United States)

    Murugan, R; Panduranga Rao, K

    2003-01-01

    Graft polymerization of glycidylmethacrylate (GMA) onto coralline hydroxyapatite (CHA) was carried out using potassium persulfate (K2S2O8) and sodium metabisulfite (Na2S2O5) as initiators in aqueous medium. To optimize the reaction conditions for getting maximum grafting yield, the concentrations of backbone, monomer, initiator, temperature and time were varied. The percent grafting was found to increase initially and then gradually decrease with respect to reaction parameters. The results obtained imply that the optimum temperature and time was 60 degrees C and 180 min, respectively, to obtain higher grafting yield. The grafting results have been discussed and a mechanism involved in the grafting of GMA onto CHA is described. The grafted materials were analyzed with Fourier transform infrared (FT-IR) spectroscopy and X-ray diffraction (XRD) measurements. The results of FT-IR confirmed the presence of epoxy group on the grafted CHA. The XRD pattern showed that there was no secondary phase in the apatite lattice due to chemical modification.

  15. The effect of monomer molecular weight on grafting reaction

    International Nuclear Information System (INIS)

    Wu Minghong; Ding Zhongli; Ma Zueteh

    1995-01-01

    In this paper, some condensed ethylene glycol acrylate monomers with different molecular weight being grafted to the PE film by means of pre-irradiation is reported. The effect of molecular weight of monomer on grafting reaction and the hydrophilicity of grafting sample have been discussed. The experimental results show: molar degrees of grafting decreased non-linearly with the increasement of molecular weight of monomer, the grafting reaction of polymer is greater effected by the swelling degree of PE film, the greater the swelling degree of grafting material, the higher the grating degree grafting is, the initial rate of grafting reaction decreased with the increasement of molecular weight of monomer. (author)

  16. Coaxial electrospinning multicomponent functional controlled-release vascular graft: Optimization of graft properties.

    Science.gov (United States)

    Yin, Anlin; Luo, Rifang; Li, Jiukai; Mo, Xiumei; Wang, Yunbing; Zhang, Xingdong

    2017-04-01

    Small diameter vascular grafts possessing desirable biocompatibility and suitable mechanical properties have become an urgent clinic demand. Herein, heparin loaded fibrous grafts of collagen/chitosan/poly(l-lactic acid-co-ε-caprolactone) (PLCL) were successfully fabricated via coaxial electrospinning. By controlling the concentration of heparin and the ratio of collagen/chitosan/PLCL, most grafts had the heparin encapsulation efficiency higher than 70%, and the heparin presented sustained release for more than 45 days. Particularly, such multicomponent grafts had relative low initial burst release, and after heparin releasing for 3 weeks, the grafts still showed good anti-platelet adhesion ability. In addition, along with the excellent cell biocompatibility, the fabricated grafts possessed suitable mechanical properties including good tensile strength, suture retention strength, burst pressure and compliance which could well match the native blood vessels. Thus, the optimized graft properties could be properly addressed for vascular tissue application via coaxial electrospinning. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Polyethylene oxide hydration in grafted layers

    Science.gov (United States)

    Dormidontova, Elena; Wang, Zilu

    Hydration of water soluble polymers is one of the key-factors defining their conformation and properties, similar to biopolymers. Polyethylene oxide (PEO) is one of the most important biomedical-applications polymers and is known for its reverse temperature solubility due to hydrogen bonding with water. As in many practical applications PEO chains are grafted to surfaces, e.g. of nanoparticles or planar surfaces, it is important to understand PEO hydration in such grafted layers. Using atomistic molecular dynamic simulations we investigate the details of molecular conformation and hydration of PEO end-grafted to gold surfaces. We analyze polymer and water density distribution as a function of distance from the surface for different grafting densities. Based on a detailed analysis of hydrogen bonding between polymer and water in grafted PEO layers, we will discuss the extent of PEO hydration and its implication for polymer conformation, mobility and layer properties. This research is supported by NSF (DMR-1410928).

  18. Graft Take-Rates After Tympanoplasty

    DEFF Research Database (Denmark)

    Andersen, Steven Arild Wuyts; Aabenhus, Kristine; Glad, Henrik

    2014-01-01

    OBJECTIVE: To present a prospective ear surgery database and investigate the graft take-rate and prognostic factors for graft take-rate in tympanoplasty using the database. STUDY DESIGN: Prospective database study. SETTING: Tertiary referral center. PATIENTS: A total of 1606 cases undergoing...... tympanoplasty types I to IV were registered in the database in the period from February 2004 to November 2013. INTERVENTION: A total of 837 cases underwent myringoplasty/tympanoplasty type I. MAIN OUTCOME MEASURE: Graft take-rate and prognostic factors (age, discharge at time of surgery, tuba function......, technique, graft material, and revision surgery) for tympanoplasty type I were studied. A comparison with the graft take-rates for tympanoplasty types II to IV and/or cholesteatoma was made. RESULTS: A user-friendly ear surgery database with fast data entry and direct import of audiometric data...

  19. Evaluation of synthetic vascular grafts in a mouse carotid grafting model.

    Directory of Open Access Journals (Sweden)

    Alex H P Chan

    Full Text Available Current animal models for the evaluation of synthetic grafts are lacking many of the molecular tools and transgenic studies available to other branches of biology. A mouse model of vascular grafting would allow for the study of molecular mechanisms of graft failure, including in the context of clinically relevant disease states. In this study, we comprehensively characterise a sutureless grafting model which facilitates the evaluation of synthetic grafts in the mouse carotid artery. Using conduits electrospun from polycaprolactone (PCL we show the gradual development of a significant neointima within 28 days, found to be greatest at the anastomoses. Histological analysis showed temporal increases in smooth muscle cell and collagen content within the neointima, demonstrating its maturation. Endothelialisation of the PCL grafts, assessed by scanning electron microscopy (SEM analysis and CD31 staining, was near complete within 28 days, together replicating two critical aspects of graft performance. To further demonstrate the potential of this mouse model, we used longitudinal non-invasive tracking of bone-marrow mononuclear cells from a transgenic mouse strain with a dual reporter construct encoding both luciferase and green fluorescent protein (GFP. This enabled characterisation of mononuclear cell homing and engraftment to PCL using bioluminescence imaging and histological staining over time (7, 14 and 28 days. We observed peak luminescence at 7 days post-graft implantation that persisted until sacrifice at 28 days. Collectively, we have established and characterised a high-throughput model of grafting that allows for the evaluation of key clinical drivers of graft performance.

  20. Early postoperative angiographic assessment of radial grafts used for coronary artery bypass grafting.

    Science.gov (United States)

    Chen, A H; Nakao, T; Brodman, R F; Greenberg, M; Charney, R; Menegus, M; Johnson, M; Grose, R; Frame, R; Hu, E C; Choi, H K; Safyer, S

    1996-06-01

    Despite a revival of interest in using the radial artery as an alternative conduit for myocardial revascularization, little angiographic documentation of early postoperative results has been presented, particularly in North America. Accordingly, 60 of 150 patients who underwent coronary artery bypass with radial arteries from November 1993 to July 1995 have had postoperative cardiac catheterization at our institution. The patency rate of the radial artery grafts was 95.7% (90 of 94 grafts patent) with an average internal diameter of 2.51 mm. Four radial artery grafts showed diffuse narrowing. The patency rate of the internal thoracic artery grafts was 100% with an average internal diameter of 2.25 mm. Three of 62 grafts demonstrated diffuse narrowing. Two of 24 (7.7%) saphenous vein grafts were occluded; the average internal diameter was 3.23 mm. The internal thoracic artery, the radial artery, and saphenous vein grafts were, respectively, 7.5%, 19.5%, and 53.3% larger than the anastomosed native coronary arteries. Graft-dependent flow was found in 81.1% of the radial artery grafts. The results of this study demonstrate that the short-term patency rate of radial artery grafts is excellent.

  1. Hot callusing for propagation of American beech by grafting

    Science.gov (United States)

    David W. Carey; Mary E. Mason; Paul Bloese; Jennifer L. Koch

    2013-01-01

    To increase grafting success rate, a hot callus grafting system was designed and implemented as part of a multiagency collaborative project to manage beech bark disease (BBD) through the establishment of regional BBD-resistant grafted seed orchards. Five years of data from over 2000 hot callus graft attempts were analyzed using a logistic regression model to determine...

  2. Graft Copolymerization of Acrylonitrile and Ethyl Methacrylate on ...

    African Journals Online (AJOL)

    Graft copolymers of Acrylonitrile and ethyl methcrylate on dextrin were prepared by the use of ceric ion initiator in aqueous medium at 290C. The molecular weight of grafted poly(ethyl methacrylate) chains were higher than for polyacrylonitrile grafts; but the latter were more frequently grafted on the backbone polymer.

  3. Revascularisation of fresh compared with demineralised bone grafts in rats

    DEFF Research Database (Denmark)

    Solheim, E; Pinholt, E M; Talsnes, O

    2001-01-01

    Revascularisation of bone grafts is influenced by both the anatomical origin and the pre-implantation processing of the graft. We investigated the revascularisation by entrapment of 141Ce (cerium)-labelled microspheres in large, fresh and demineralised syngeneic grafts of predominantly cancellous...... iliac bone grafts, p = 0.8. The results suggest that whereas fresh cancellous grafts are revascularised more completely than fresh cortical grafts, there is no difference in the revascularisation of demineralised cancellous and cortical grafts. In addition, fresh cancellous bone is revascularised more...... completely than demineralised cancellous bone, whereas there is no difference between fresh and demineralised cortical bone....

  4. Left Atrial Myxoma Following Coronary Artery Bypass Grafting with Patient Coronary Arterial Grafts: a Rarity.

    Science.gov (United States)

    Patel, Kartik; Rahul, Kumar; Tarsaria, Malkesh; Malhotra, Amber

    2017-01-01

    The development of left atrial myxoma after coronary artery bypass graft surgery is a rare entity. A 60-year-old man with previous off-pump coronary artery bypass grafting four years ago with patent coronary grafts was diagnosed with left atrial mass. The patient underwent successful resection of the same through minimally invasive right anterolateral thoracotomy. Histopathology of the atrial mass confirmed the diagnosis of atrial myxoma.

  5. Cambial Isoperoxidases Related to Graft Compatibility in Pear-Quince Graft Combinations

    OpenAIRE

    GÜLEN*, Hatice; ÇELİK, Menşure; POLAT, Mehmet; ERİŞ, Atilla

    2014-01-01

    This study was initiated to survey the graft compatibility characteristics of some selected quince clones known as "S.Ö." with regard to isoperoxidase markers. Compatible (Beurre Hardy = BH) and incompatible (Bartlett = BT) pear cultivars were grafted on quince A (QA) and 13 S.Ö. quince clones by T budding. Bark tissues were collected from the union (4, 8 and 12 weeks after grafting) and from unbudded rootstocks in addition to current-year shoots of 2 pear scions to investig...

  6. Study on preirradiation grafting of methacrylamide onto natural silk fabrics

    International Nuclear Information System (INIS)

    Xiang Zhengyu; Wan Dairong

    1997-09-01

    In order to improve the properties of natural silk fabrics, the mechanism and method of the radiation induced graft copolymerization of monomers onto natural silk fabrics were more studied. Grafting of methacrylamide onto natural silk fabrics by the preirradiation grafting method have been made. The dependencies of the grafting yield on preirradiation dose, dose rates, grafting reaction time, monomers content and moisture in sample were investigated respectively. The mechanism of the preirradiation grafting was discussed. The comparison of the preirradiation grafting method with the radiation-induced solid phase graft copolymerization was made. It is evident that the preirradiation grafting method has many advantages. It can carry out surface layer graft of monomer onto natural silk fabrics. The printing and dyeing performance was improved and so on. (5 refs., 5 figs., 1 tab.)

  7. Efficient decellularization for tissue engineering of the tendon-bone interface with preservation of biomechanics.

    Directory of Open Access Journals (Sweden)

    Kai Xu

    Full Text Available Interfaces between tendon/ligament and bone ("entheses" are highly specialized tissues that allow for stress transfer between mechanically dissimilar materials. Entheses show very low regenerative capacity resulting in high incidences of failure after surgical repair. Tissue engineering is a promising approach to recover functionality of entheses. Here, we established a protocol to decellularize porcine entheses as scaffolds for enthesis tissue engineering. Chemical detergents as well as physical treatments were investigated with regard to their efficiency to decellularize 2 mm thick porcine Achilles tendon entheses. A two-phase approach was employed: study 1 investigated the effect of various concentrations of sodium dodecyl sulfate (SDS and t-octylphenoxypolyethoxy-ethanol (Triton X-100 as decellularization agents. The most efficient combination of SDS and Triton was then carried forward into study 2, where different physical methods, including freeze-thaw cycles, ultrasound, perfusion, and hydrostatic washing were used to enhance the decellularization effect. Cell counts, DNA quantification, and histology showed that washing with 0.5% SDS + 1% Triton X-100 for 72 h at room temperature could remove ~ 98% cells from the interface. Further investigation of physical methods proved that washing under 200 mmHg hydrostatic pressure shortened the detergent exposing time from 72 h to 48 h. Biomechanical tensile testing showed that the biomechanical features of treated samples were preserved. Washing under 200 mmHg hydrostatic pressure with 0.5% SDS + 1% Triton X-100 for 48 h efficiently decellularized entheses with preservation of matrix structure and biomechanical features. This protocol can be used to efficiently decellularize entheses as scaffolds for tissue engineering.

  8. The role of bone sialoprotein in the tendon-bone insertion.

    Science.gov (United States)

    Marinovich, Ryan; Soenjaya, Yohannes; Wallace, Gregory Q; Zuskov, Andre; Dunkman, Andrew; Foster, Brian L; Ao, Min; Bartman, Kevin; Lam, Vida; Rizkalla, Amin; Beier, Frank; Somerman, Martha J; Holdsworth, David W; Soslowsky, Louis J; Lagugné-Labarthet, François; Goldberg, Harvey A

    2016-01-01

    Tendons/ligaments insert into bone via a transitional structure, the enthesis, which is susceptible to injury and difficult to repair. Fibrocartilaginous entheses contain fibrocartilage in their transitional zone, part of which is mineralized. Mineral-associated proteins within this zone have not been adequately characterized. Members of the Small Integrin Binding Ligand N-linked Glycoprotein (SIBLING) family are acidic phosphoproteins expressed in mineralized tissues. Here we show that two SIBLING proteins, bone sialoprotein (BSP) and osteopontin (OPN), are present in the mouse enthesis. Histological analyses indicate that the calcified zone of the quadriceps tendon enthesis is longer in Bsp(-/-) mice, however no difference is apparent in the supraspinatus tendon enthesis. In an analysis of mineral content within the calcified zone, micro-CT and Raman spectroscopy reveal that the mineral content in the calcified fibrocartilage of the quadriceps tendon enthesis are similar between wild type and Bsp(-/-) mice. Mechanical testing of the patellar tendon shows that while the tendons fail under similar loads, the Bsp(-/-) patellar tendon is 7.5% larger in cross sectional area than wild type tendons, resulting in a 16.5% reduction in failure stress. However, Picrosirius Red staining shows no difference in collagen organization. Data collected here indicate that BSP is present in the calcified fibrocartilage of murine entheses and suggest that BSP plays a regulatory role in this structure, influencing the growth of the calcified fibrocartilage in addition to the weakening of the tendon mechanical properties. Based on the phenotype of the Bsp(-/-) mouse enthesis, and the known in vitro functional properties of the protein, BSP may be a useful therapeutic molecule in the reattachment of tendons and ligaments to bone. Copyright © 2016 International Society of Matrix Biology. All rights reserved.

  9. Determination of the distribution of graft yields following a radiation-induced graft copolymerization

    International Nuclear Information System (INIS)

    Schipschack, K.; Wagner, H.; Sawtschenko, L.

    1976-01-01

    In the radiation-induced graft copolymerization on solid initial polymers a distribution of graft yields takes place along the cross-sections of samples. Methods for determining this distribution, which are described in the literature, are reviewed. In our own investigations boards made of ethylene-vinyl acetate copolymers and grafted with vinyl chloride were used. Distributions of the grafted component obtained by infrared analysis of microtome cuts parallel to the surface are partly rather inhomogeneous, and are interpreted as dependent on the experimental parameters. (author)

  10. Nasal Reconstrution in Revisional Rhinoplasty with Rib Graft and Olecranon Graft: Two Cases of Report

    OpenAIRE

    Pedraza Mantilla, Álvaro; Hospital Universitario San Ignacio-Pontificia Universidad Javeriana; Gélvez Rondón, Natalia; Pontificia Universidad Javeriana-Hospital Universitario San Ignacio

    2015-01-01

    Revisional rhinoplasty is a challenge for the nose surgeon. In most cases there is no septal cartilage, because that has been resected and used as a graft in previous interventions. Grafts olecranon and rib provide the properties needed to give support in the revisionales septorhinoplasty. This article presents detailed surgical technique in two males with multiple previous interventions. In one case of rib grafts were obtained in the same surgical time, in the other case, olecranon graft obt...

  11. Enrichment of autologous fat grafts with ex-vivo expanded adipose tissue-derived stem cells for graft survival

    DEFF Research Database (Denmark)

    Kølle, Stig-Frederik Trojahn; Fischer-Nielsen, Anne; Mathiasen, Anders Bruun

    2013-01-01

    Autologous fat grafting is increasingly used in reconstructive surgery. However, resorption rates ranging from 25% to 80% have been reported. Therefore, methods to increase graft viability are needed. Here, we report the results of a triple-blind, placebo-controlled trial to compare the survival ...... of fat grafts enriched with autologous adipose-derived stem cells (ASCs) versus non-enriched fat grafts....

  12. Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones

    Directory of Open Access Journals (Sweden)

    Ying Guan

    2016-08-01

    Full Text Available Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU and polyester graft (nitinol-PET materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft.

  13. The science behind autologous fat grafting

    Directory of Open Access Journals (Sweden)

    Elisa Bellini

    2017-12-01

    Despite ongoing concerns about survival and longevity of fat grafts after implantation and unpredictability of long-term outcome, fat has been successfully used as a filler in many differ clinic situation.

  14. Free Gingival Graft versus Mucograft: Histological Evaluation

    Directory of Open Access Journals (Sweden)

    Zaklina Menceva

    2018-03-01

    CONCLUSION: The patients treated with a free gingival graft showed a larger presence of fragmented collagen tissue and fragmented elastic fibres, whereas a mature tissue was predominantly present in the surgical area where a Geistlich Mucograft was placed.

  15. Non-Anastomotic Rupture of a Woven Dacron Graft in the Descending Thoracic Aorta Treated with Endovascular Stent Grafting

    Directory of Open Access Journals (Sweden)

    Youngok Lee

    2016-12-01

    Full Text Available The intrinsic structural failure of a Dacron graft resulting from the loss of structural integrity of the graft fabric can cause late graft complications. Late non-anastomotic rupture has traditionally been treated surgically via open thoracotomy. We report a case of the successful use of thoracic endovascular repair to treat a Dacron graft rupture in the descending aorta. The rupture occurred 20 years after the graft had been placed. Two stent grafts were placed at the proximal portion of the surgical graft, covering almost its entire length.

  16. DNA nanosensor surface grafting and salt dependence

    Science.gov (United States)

    Carvalho, B. G.; Fagundes, J.; Martin, A. A.; Raniero, L.; Favero, P. P.

    2013-02-01

    In this paper we investigated the Paracoccidoides brasiliensis fungus nanosensor by simulations of simple strand DNA grafting on gold nanoparticle. In order to improve the knowledge of nanoparticle environment, the addiction of salt solution was studied at the models proposed by us. Nanoparticle and DNA are represented by economic models validated by us in this paper. In addition, the DNA grafting and salt influences are evaluated by adsorption and bond energies calculations. This theoretical evaluation gives support to experimental diagnostics techniques of diseases.

  17. Additive effects in radiation grafting and curing

    International Nuclear Information System (INIS)

    Viengkhou, V.; Ng, L.

    1996-01-01

    Full text: Detailed studies on the accelerative effect of novel additives in radiation grafting and curing using acrylated monomer/oligomer systems have been performed in the presence of ionising radiation and UV as sources. Methyl methacrylate (MMA) is used as typical monomer for these grafting studies in the presence of the additives with model backbone polymers, cellulose and propropylene. Additives which have been found to accelerate these grafting processes are: mineral acid, occlusion compounds like urea, thermal initiators and photoinitiators as well as multifunctional monomers such as multifunctional acrylates. The results from irradiation with gamma rays have also been compared with irradiation from a 90W UV lamp. The role of the above additives in accelerating the analogous process of radiation curing has been investigated. Acrylated urethanes, epoxies and polyesters are used as oligomers together with acrylated monomers in this work with uv lamps of 300 watts/inch as radiation source. In the UV curing process bonding between film and substrate is usually due to physical forces. In the present work the presence of additives are shown to influence the occurrence of concurrent grafting during cure thus affecting the nature of the bonding of the cured film. The conditions under which concurrent grafting with UV can occur will be examined. A mechanism for accelerative effect of these additives in both grafting and curing processes has been proposed involving radiation effects and partitioning phenomena

  18. Polypeptide Grafted Hyaluronan: Synthesis and Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiaojun [ORNL; Messman, Jamie M [ORNL; Mays, Jimmy [ORNL; Baskaran, Durairaj [University of Tennessee, Knoxville (UTK)

    2010-01-01

    Poly(L-leucine) grafted hyaluronan (HA-g-PLeu) has been synthesized via a Michael addition reaction between primary amine terminated poly(L-leucine) and acrylate-functionalized HA (TBAHA-acrylate). The precursor hyaluronan was first functionalized with acrylate groups by reaction with acryloyl chloride in the presence of triethylamine in N,N-dimethylformamide. 1H NMR analysis of the resulting product indicated that an increase in the concentration of acryloylchoride with respect to hydroxyl groups on HA has only a moderate effect on functionalization efficiency, f. A precise control of stoichiometry was not achieved, which could be attributed to partial solubility of intermolecular aggregates and the hygroscopic nature of HA. Michael addition at high [PLeu- NH2]/[acrylate]TBAHA ratios gave a molar grafting ratio of only 0.20 with respect to the repeat unit of HA, indicating grafting limitation due to insolubility of the grafted HA-g-PLeu. Soluble HA-g-PLeu graft copolymers were obtained for low grafting ratios (<0.039) with <8.6% by mass of PLeu and were characterized thoroughly using light scattering, 1H NMR, FT-IR, and AFM techniques. Light scattering experiments showed a strong hydrophobic interaction between PLeu chains, resulting in aggregates with segregated nongrafted HA segments. This yields local networks of aggregates, as demonstrated by atomic force microscopy. Circular dichroism spectroscopy showed a -sheet conformation for aggregates of poly(L-leucine).

  19. Isotopic scintigraphy in kidney grafting

    International Nuclear Information System (INIS)

    Renfro, Richard.

    1976-01-01

    Isotopic explorations of kidney transplants were performed on sixty-six patients. Three scintigraphic techniques were used: labelled ferrous ascorbate scintigraphy, sequential 99m technetium DTPA scintigraphy and the 131 I hippuran nephrogram. The aim of this study is to analyse the results obtained under different pathological circumstances affecting the transplant, to discuss the advantages of the techniques and to propose a working procedure. The most reliable and accurate technique is the 131 I hippuran nephrogram combined with sequential 99mTc DTPA, by which renal vascularisation may be judged labelled ferrous ascorbate on the other hand is too insensitive. Although the information supplied is mostly contained in the scintigraphic images, the nephrographic curves and the blood radioactivity decay time and rad V/rad R ratio measurements are very helpful in the early diagnosis and differential diagnosis of complications affecting the transplant. The proper use of isotopic scintigraphy in kidney grafting should provide optimum conditions for better survival of the transplant at minimum risk to the patient [fr

  20. Role of graft oversizing in the fixation strength of barbed endovascular grafts.

    Science.gov (United States)

    Kratzberg, Jarin A; Golzarian, Jafar; Raghavan, Madhavan L

    2009-06-01

    The role of endovascular graft oversizing on risk of distal graft migration following endovascular aneurysm repair for abdominal aortic aneurysm is poorly understood. A controlled in vitro investigation of the role of oversizing in graft-aorta attachment strength for endovascular grafts (EVGs) with barbs was performed. Barbed stent grafts (N = 20) with controlled graft oversizing varying from 4-45% were fabricated while maintaining other design variables unchanged. A flow loop with physiological flow characteristics and a biosynthetic aortic aneurysm phantom (synthetic aneurysm model with a bovine aortic neck) were developed. The stent grafts were deployed into the aortic neck of the bio-synthetic aortic aneurysm phantom under realistic flow conditions. Computed tomography imaging of the graft-aorta complex was used to document attachment characteristics such as graft apposition, number of barbs penetrated, and penetration depth and angle. The strength of graft attachment to the aortic neck was assessed using mechanical pullout testing. Stent grafts were categorized into four groups based on oversizing: 4-10%; 11-20%; 21-30%; and greater than 30% oversizing. Pullout force, a measure of post-deployment fixation strength was not different between 4-10% (6.23 +/- 1.90 N), 11-20% (6.25 +/- 1.84 N) and 20-30% (5.85 +/- 1.89 N) groups, but significantly lower for the group with greater than 30% oversizing (3.67 +/- 1.41 N). Increasing oversizing caused a proportional decrease in the number of barbs penetrating the aortic wall (correlation = -0.83). Of the 14 barbs available in the stent graft, 89% of the barbs (12.5 of 14 on average) penetrated the aortic wall in the 4-10% oversizing group while only 38% (5.25 of 14) did for the greater than 30% group (P barb penetration were found to be positively correlated to pullout force. Greater than 30% graft oversizing affects both barb penetration and graft apposition adversely resulting in a low pullout force in this in vitro

  1. Physical properties of agave cellulose graft polymethyl methacrylate

    International Nuclear Information System (INIS)

    Rosli, Noor Afizah; Ahmad, Ishak; Abdullah, Ibrahim; Anuar, Farah Hannan

    2013-01-01

    The grafting polymerization of methyl methacrylate and Agave cellulose was prepared and their structural analysis and morphology were investigated. The grafting reaction was carried out in an aqueous medium using ceric ammonium nitrate as an initiator. The structural analysis of the graft copolymers was carried out by Fourier transform infrared and X-ray diffraction. The graft copolymers were also characterized by field emission scanning electron microscopy (FESEM). An additional peak at 1732 cm −1 which was attributed to the C=O of ester stretching vibration of poly(methyl methacrylate), appeared in the spectrum of grafted Agave cellulose. A slight decrease of crystallinity index upon grafting was found from 0.74 to 0.68 for cellulose and grafted Agave cellulose, respectively. Another evidence of grafting showed in the FESEM observation, where the surface of the grafted cellulose was found to be roughed than the raw one

  2. Physical properties of agave cellulose graft polymethyl methacrylate

    Science.gov (United States)

    Rosli, Noor Afizah; Ahmad, Ishak; Abdullah, Ibrahim; Anuar, Farah Hannan

    2013-11-01

    The grafting polymerization of methyl methacrylate and Agave cellulose was prepared and their structural analysis and morphology were investigated. The grafting reaction was carried out in an aqueous medium using ceric ammonium nitrate as an initiator. The structural analysis of the graft copolymers was carried out by Fourier transform infrared and X-ray diffraction. The graft copolymers were also characterized by field emission scanning electron microscopy (FESEM). An additional peak at 1732 cm-1 which was attributed to the C=O of ester stretching vibration of poly(methyl methacrylate), appeared in the spectrum of grafted Agave cellulose. A slight decrease of crystallinity index upon grafting was found from 0.74 to 0.68 for cellulose and grafted Agave cellulose, respectively. Another evidence of grafting showed in the FESEM observation, where the surface of the grafted cellulose was found to be roughed than the raw one.

  3. [Experimental study of allogenic tendon with sheath grafting in chicken].

    Science.gov (United States)

    Zhang, Y L; Wang, S L; Gao, X S

    2001-03-01

    To investigate availability of deep freeze stored allogenic tendon with sheath grafting in repairing the tendon and sheath defect in the II area of flexor digitorum tendon. Sixty chickens with tendon and sheath defect were divided into 2 groups randomly, group A was treated with allogenic grafting and group B was treated with autogenic grafting, these two groups were divided into two subgroups respectively, they were, group A1 allogenic tendon with whole sheath grafting, group A2 allogenic tendon with partial sheath grafting, group B1 autogenic tendon with whole sheath grafting and group B2 autogenic tendon with whole sheath grafting. All the allogenic grafts were treated by deep freeze. Histomorphological study, histoimmunological study and slipping function of the grafts were measured after operation. In group A1 and B1, the local reaction was sever, the nutrition of tendon graft was barricaded by the whole sheath resulting in adhesion, degeneration and necrosis. In group A2 and B2, the tendon graft healed well and little adhesion existed between tendon and sheath. The results showed that there were significant differences between tendon grafting with whole sheath and tendon grafting with partial sheath. Deep freeze store can reduce the immunogenicity of allogenic tendon with sheath. Allogenic tendon with partial sheath grafting can be used as a new biological material for repairing the tendon and sheath defect.

  4. Structural implications of fenestrated stent graft misalignment.

    Science.gov (United States)

    Crawford, S A; Itkina, M; Doyle, M G; Tse, L W; Amon, C H; Roche-Nagle, G

    2018-04-01

    Endovascular aneurysm repair is a minimally-invasive method for the treatment of abdominal aortic aneurysms. For aneurysms that involve the visceral arteries, a custom-made stent graft with fenestrations for the branch arteries is required. The purpose of the current study is to evaluate the structural impact of misaligned fenestrations with respect to luminal patency and proximal aortic neck apposition in an in vitro model. A custom apparatus was used to evaluate seven Anaconda and three Zenith fenestrated stent grafts. All stent grafts were evaluated at 10° increments of stent/fenestration misalignment up to 80°. Images were captured at each interval and the luminal cross-sectional area and wall apposition were measured. The Anaconda stent graft, which has an unsupported main body, demonstrated a linear reduction in luminal patency at increasing angles of misalignment (P < 0.0001). Stent/fenestration misalignments of 20° and 80° resulted in decreases in mean luminal patency of 14% and 54% respectively. The Zenith stent graft demonstrated a similar decrease in luminal patency, starting at misalignments of ≥40° (P < 0.0001). However, with stent/fenestration misalignments of ≥30°, apposition between the Zenith stent graft and the simulated aortic neck was compromised suggesting the creation of a type Ia endoleak. Both the Anaconda and Zenith devices behave adversely at extreme angles of misalignment with luminal narrowing in the Anaconda device and loss of wall apposition in the Zenith device; however, both stent grafts appear to be equivalent at low angles of misalignment. Copyright © 2016 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  5. Complications in skin grafts when continuing antithrombotic therapy prior to cutaneous surgery requiring skin grafting

    DEFF Research Database (Denmark)

    Jarjis, Reem Dina; Jørgensen, Lone; Finnerup, Kenneth

    2015-01-01

    in terms of hemostasis by the surgeon and good pressure dressings. Care should be taken when operating on anticoagulated patients undergoing cutaneous surgery requiring skin grafting. However, graft failure is rare and, given the risk of thrombotic events, the reviewed studies recommend continuing all......Abstract The risk of postoperative bleeding and wound healing complications in skin grafts among anticoagulated patients undergoing cutaneous surgery has not been firmly established. The objective was to examine the literature and assess the risk of postoperative bleeding or wound healing...... complications in skin grafts among anticoagulated patients, compared with patients who discontinue or patients who are not receiving antithrombotic therapy prior to cutaneous surgery requiring skin grafting. A systematic review examining the effect of antithrombotic therapy on cutaneous surgery was performed...

  6. Acute graft versus host disease

    Directory of Open Access Journals (Sweden)

    Vogelsang Georgia B

    2007-09-01

    Full Text Available Abstract Acute graft-versus-host disease (GVHD occurs after allogeneic hematopoietic stem cell transplant and is a reaction of donor immune cells against host tissues. Activated donor T cells damage host epithelial cells after an inflammatory cascade that begins with the preparative regimen. About 35%–50% of hematopoietic stem cell transplant (HSCT recipients will develop acute GVHD. The exact risk is dependent on the stem cell source, age of the patient, conditioning, and GVHD prophylaxis used. Given the number of transplants performed, we can expect about 5500 patients/year to develop acute GVHD. Patients can have involvement of three organs: skin (rash/dermatitis, liver (hepatitis/jaundice, and gastrointestinal tract (abdominal pain/diarrhea. One or more organs may be involved. GVHD is a clinical diagnosis that may be supported with appropriate biopsies. The reason to pursue a tissue biopsy is to help differentiate from other diagnoses which may mimic GVHD, such as viral infection (hepatitis, colitis or drug reaction (causing skin rash. Acute GVHD is staged and graded (grade 0-IV by the number and extent of organ involvement. Patients with grade III/IV acute GVHD tend to have a poor outcome. Generally the patient is treated by optimizing their immunosuppression and adding methylprednisolone. About 50% of patients will have a solid response to methylprednisolone. If patients progress after 3 days or are not improved after 7 days, they will get salvage (second-line immunosuppressive therapy for which there is currently no standard-of-care. Well-organized clinical trials are imperative to better define second-line therapies for this disease. Additional management issues are attention to wound infections in skin GVHD and fluid/nutrition management in gastrointestinal GVHD. About 50% of patients with acute GVHD will eventually have manifestations of chronic GVHD.

  7. Adolescent External Iliac Artery Trauma: Recurrent Aneurysmal Dilatation of an Iliofemoral Saphenous Vein Graft Treated by Stent-Grafting

    International Nuclear Information System (INIS)

    Lenton, James; Davies, John; Homer-Vanniasinkam, S.; McPherson, Simon

    2008-01-01

    An adolescent male sustained a severe penetrating injury to the external iliac artery. Emergency surgical revascularization was with a reversed long saphenous vein interposition graft. The primary graft and the subsequent revision graft both became aneurysmal. The second graft aneurysm was successfully excluded by endovascular stent-grafts with medium-term primary patency. A venous graft was used initially rather than a synthetic graft to reduce the risk of infection and the potential problems from future growth. Aneurysmal dilatation of venous grafts in children and adolescents is a rare but recognized complication. To the best of our knowledge, exclusion of these aneurysms with stent-grafts has not been previously reported in the adolescent population.

  8. Radiographic analysis of pasteurized autologous bone graft

    International Nuclear Information System (INIS)

    Ahmed, Adel Refaat; Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi

    2003-01-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  9. Radiographic analysis of pasteurized autologous bone graft.

    Science.gov (United States)

    Ahmed, Adel Refaat; Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi

    2003-08-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors.

  10. Radiographic analysis of pasteurized autologous bone graft

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Adel Refaat [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan); Department of Orthopedic Surgery, Alexandria University, Alexandria (Egypt); Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan)

    2003-08-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  11. Strengthening of polycaproamide fibers with grafted polyacrylonitrile

    International Nuclear Information System (INIS)

    Kurilenko, A.I.; Kalinin, V.N.; Kot, L.G.

    1976-01-01

    By direct irradiation of polycaproamide fibers in an acrylonitrile medium, modified fibers with average uniform distribution of discrete grafted polyacrylonitrile molecules along the cross section are obtained. In the range of temperatures from - 196 to -300 deg C, which encompasses all states of grafted polymers, a study is made of how the strength and the deformation properties of the modified fibers are related to the concentration of polyacrylonitrile which has been varied from 0.5 to 0.76% by vol. Also the effects of the grafting process and orientation stretching on the strength and deformation properties of the modified fibers are examined. The presence of polyacrylonitrile produces an additive effect on the strength and deformation properties of the grafted fibers. A quantitative analysis of the results of measurements of the strength of the grafted fibers has been made on the basis of a cross-linked macromolecule model, the nodes in which are formed by the hypermolecular structures and on the assumption that the nodes are the weak points in the cross-linked macromolecule

  12. Long-term results of PTFE grafts.

    Science.gov (United States)

    Hedin, Ulf

    2015-01-01

    Vascular surgeons are essential in "lifeline" creation for hemodialysis patients and should be the central player in any multidisciplinary access service together with nephrologists, dialysis staff and interventional radiology. In this position, access surgeons are involved in complicated clinical decision making regarding primary and secondary access selection, which throughout the last decade has been largely aided, and influenced, by national and international guidelines as well as other initiatives. These recommendations, unanimously and appropriately, advocate the placement of native fistulas over synthetic grafts (the majority grafts from expanded polytetrafluoroethylene, ePTFE, herein referred to as PTFE) based on the superiority of fistulas with respect to complications such as infections and thrombosis. Nevertheless, the use of PTFE grafts for hemodialysis access is an accepted and firmly established alternative to native fistulas where data today reveal unwanted consequences to overinterpretation of established guidelines such as increased catheter use. This information highlights a need for an adjustment of access selection strategies based on patient-centered algorithms. Here, available results on PTFE graft performance in hemodialysis access is recapitulated, with respect to both conventional grafts and technical modifications, and conclude with a modified approach to primary access selection.

  13. Polymer Grafted Nanoparticle-based Oil Dispersants

    Science.gov (United States)

    Kim, Daehak; Krishnamoorti, Ramanan

    2015-03-01

    Particle-based oil dispersants mainly composed of inorganic nanoparticles such as silica nanoparticles are considered as environmentally friendly oil dispersants due to their biocompatibility and relatively low toxicity. The oil-water interfacial tension is reduced when nanoparticles segregate to the oil-water interface and this segregation is improved by grafting interfacially active polymer brushes. In this study, surfactant-like amphiphilic block copolymers were grafted from silica nanoparticles using an atom transfer radical polymerization (ATRP) method in order to increase their interfacial activity. We have studied the interfacial activity of such hybrid nanoparticles using pendant drop interfacial tension measurements, and their structure using small angle X-ray scattering. Amphiphilic copolymer grafted nanoparticles significantly reduced oil-water interfacial tension compared to the interfacial tension reduction induced by homopolymer grafted nanoparticles or the corresponding free ungrafted copolymer. Moreover, hard and stable oil-water emulsions were formed by applying the block copolymer grafted nanoparticles due to the formation of interparticle network structures, which were observed by cryo-scanning electron microscopy (SEM) and small angle neutron scattering (SANS)

  14. Aortic reconstruction with bovine pericardial grafts

    Directory of Open Access Journals (Sweden)

    Silveira Lindemberg Mota

    2003-01-01

    Full Text Available INTRODUCTION: Glutaraldehyde-treated crimped bovine pericardial grafts are currently used in aortic graft surgery. These conduits have become good options for these operations, available in different sizes and shapes and at a low cost. OBJECTIVE:To evaluate the results obtained with bovine pericardial grafts for aortic reconstruction, specially concerning late complications. METHOD: Between January 1995 and January 2002, 57 patients underwent different types of aortic reconstruction operations using bovine pericardial grafts. A total of 29 (50.8% were operated on an urgent basis (mostly acute Stanford A dissection and 28 electively. Thoracotomy was performed in three patients for descending aortic replacement (two patients and aortoplasty with a patch in one. All remaining 54 underwent sternotomy, cardiopulmonary bypass and aortic resection. Deep hypothermia and total circulatory arrest was used in acute dissections and arch operations. RESULTS: Hospital mortality was 17.5%. Follow-up was 24.09 months (18.5 to 29.8 months confidence interval and complication-free actuarial survival curve was 92.3% (standard deviation ± 10.6. Two patients lately developed thoracoabdominal aneurysms following previous DeBakey II dissection and one died from endocarditis. One "patch" aortoplasty patient developed local descending aortic pseudoaneurysm 42 months after surgery. All other patients are asymptomatic and currently clinically evaluated with echocardiography and CT scans, showing no complications. CONCLUSION: Use of bovine pericardial grafts in aortic reconstruction surgery is adequate and safe, with few complications related to the conduits.

  15. A COMPARATIVE STUDY OF TYMPANOPLASTY USING SLICED CARTILAGE GRAFT VS. TEMPORALIS FASCIA GRAFT

    Directory of Open Access Journals (Sweden)

    Rahul Ashok Telang

    2018-02-01

    Full Text Available BACKGROUND The objective of the study was to compare the hearing improvement after using sliced cartilage graft with that of temporalis fascia and to compare the graft take-up between the two graft materials. MATERIALS AND METHODS A prospective clinical study including 60 patients with chronic mucosal otitis media, who were selected randomly from the outpatient department, after obtaining their consent were divided into 2 groups of 30 each, and evaluated according the study protocol. Their pre-operative audiometry was recorded and both groups of patients underwent surgery with one of the graft materials- temporalis fascia or sliced tragal cartilage with a thickness of 0.5 mm. All patients were regularly followed up and post-operative audiometry was done at 3 months. The hearing improvement in the form of closure of air-bone-gap and graft take-up was analysed statistically. RESULTS The temporalis fascia graft group had a pre-operative ABG of 22.33 ± 6.24 dB and post-operative ABG of 12.33 ± 4.72 dB with hearing improvement of 10.00 dB. The sliced cartilage graft group had a pre-operative ABG of 20.77 ± 5.75 dB and postoperative ABG of 10.50 ± 4.46 dB with hearing improvement of 10.27 dB. In the temporalis fascia group, 28 (93.3% patients had good graft take-up and in the sliced cartilage group 29 (96.7% had good graft take-up. There was statistically significant hearing improvement in both of our study groups but there was no statistically significant difference between the two groups. There was no statistically significant difference in graft take-up also. CONCLUSION Sliced cartilage graft is a good auto-graft material in tympanoplasty, which can give good hearing improvement and has good graft take-up, which is comparable with that of temporalis fascia.

  16. Meshed split skin graft for extensive vitiligo

    Directory of Open Access Journals (Sweden)

    Srinivas C

    2004-05-01

    Full Text Available A 30 year old female presented with generalized stable vitiligo involving large areas of the body. Since large areas were to be treated it was decided to do meshed split skin graft. A phototoxic blister over recipient site was induced by applying 8 MOP solution followed by exposure to UVA. The split skin graft was harvested from donor area by Padgett dermatome which was meshed by an ampligreffe to increase the size of the graft by 4 times. Significant pigmentation of the depigmented skin was seen after 5 months. This procedure helps to cover large recipient areas, when pigmented donor skin is limited with minimal risk of scarring. Phototoxic blister enables easy separation of epidermis thus saving time required for dermabrasion from recipient site.

  17. [Localized purpura revealing vascular prosthetic graft infection].

    Science.gov (United States)

    Boureau, A S; Lescalie, F; Cassagnau, E; Clairand, R; Connault, J

    2013-07-01

    Prosthetic graft infection after vascular reconstruction is a rare but serious complication. We report a case of infection occurring late after implantation of an iliofemoral prosthetic vascular graft. The Staphylococcus aureus infection was revealed by vascular purpura localized on the right leg 7 years after implantation of a vascular prosthesis. This case illustrates an uncommonly late clinical manifestation presenting as an acute infection 7 years after the primary operation. In this situation, the presentation differs from early infection, which generally occurs within the first four postoperative months. Diagnosis and treatment remain a difficult challenge because prosthetic graft infection is a potentially life-threatening complication. Morbidity and mortality rates are high. Here we detail specific aspects of the clinical and radiological presentation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  18. Grafting Polymer Loops onto Functionalized Nanotubes: Monitoring Grafting and Loop Formation

    Energy Technology Data Exchange (ETDEWEB)

    Ashcraft, Earl C [ORNL; Ji, Haining [ORNL; Mays, Jimmy [ORNL; Dadmun, Mark D [ORNL

    2011-01-01

    Polystyrene functionalized at both ends (telechelic polymer) with epoxide groups (epoxy PS epoxy) was reacted with carboxylated multiwall carbon nanotubes (COOH MWNT) in solution in order to graft polymer chains at both ends onto the MWNT surface, forming loops. FT-IR spectroscopy was employed to monitor the formation of aromatic esters and to quantify the amount of telechelic grafted to the nanotube surface as a function of reaction time. When the samples were further annealed in the melt, an increase in the aromatic ester peak was observed, indicating that the unreacted chain ends further grafted to MWNT surfaces to form loops. By reacting the grafted nanotube samples further with monocarboxy terminated poly(4-methylstyrene) (COOH P4MS), the amount of epoxy PS epoxy that had only reacted at one end was determined. Reaction rate analysis indicates that that the grafting of epoxy PS epoxy to the nanotube surface is reaction controlled, as the FT-IR spectroscopy signal grows as a function of approximately t0.3. These studies exemplify how FT-IR spectroscopy can be used as a novel technique to quantify the amount of grafted polymer, grafting rate, and percent of difunctional polymers that form loops, and provide a method to create loop covered nanoparticles.

  19. Expansion techniques for skin grafts: comparison between mesh and Meek island (sandwich-) grafts.

    Science.gov (United States)

    Kreis, R W; Mackie, D P; Hermans, R R; Vloemans, A R

    1994-01-01

    In skin grafting operations for patients with extensive burn injuries, mesh techniques are often employed to enlarge the effective surface area covered by autografts. However, substantial strips of autograft are required and the distribution of autograft elements on the wound surface is relatively uneconomical. An alternative technique for expanding autografts, first described by Meek in 1958, makes use of a special dermatome and prefolded gauzes to obtain a regular expansion of autograft squares from small pieces of split skin grafts. In a simple in vitro experiment using allograft skin, the expansion ratio obtained with the Meek micrograft technique was measured at almost 1:9. In contrast, the expansion ratio obtained with allograft meshed '1:6' with a Zimmer Dermatome II was measured at 1:4. The maximum distance between the graft elements obtained with the Meek technique was 9 mm, compared to a maximal distance between the strands of the mesh graft of 12 mm. The Meek technique is a useful alternative to mesh grafts when donor sites are limited. Clinical experience suggests that Meek grafts are also particularly suitable for grafting on granulating wounds under poor conditions.

  20. Cartilage grafting in facial reconstruction with special consideration of irradiated grafts

    International Nuclear Information System (INIS)

    Donald, P.J.

    1986-01-01

    The search for the perfect facial implant for reconstruction of the face continues. Cartilage, once thought to be an undesirable graft material because of its propensity for absorption, has regained popularity in the past decade. Various preparation techniques have been employed to ensure graft sterility and diminished absorption. An improved understanding of cartilage structure and physiology has shed considerable light on the host-graft relationship. Gamma irradiation is a time-honored method of preservation. An experiment was undertaken to investigate the physiology of irradiated cartilage grafts following prolonged implantation on the facial skeleton of sheep and dog. Merthiolate preserved grafts were used as controls. Direct observation, histochemical techniques, autoradiography, and transmission electron micrography were used to determine chondrocyte viability and matrix composition. It was surprising to note that following implantation of 16 to 72 months, complete resorption was seen in 87.7% of the irradiated grafts and in 43.8% of the Merthiolate stored controls. Many of the grafts acquired chondrocytes from the host and produced new proteoglycan matrix as well as undergoing some degree of ossification. A comparison to the clinical situation in humans is made. 98 references

  1. Coracoid graft positioning in the Latarjet procedure.

    Science.gov (United States)

    Kraus, Tobias M; Graveleau, Nicolas; Bohu, Yoann; Pansard, Erwan; Klouche, Shahnaz; Hardy, Philippe

    2016-02-01

    The success of shoulder stabilization with the Latarjet procedure depends on the correct positioning of the coracoid graft at the glenoid. The aim of this study was to assess intra-observer reproducibility and inter-observer reproducibility of a new standardized CT scan analysis for coracoid graft positioning in the axial plane after the Latarjet procedure and to assess the positioning in the study group. A consecutive series of 27 patients (22 men, 5 woman, 26.1 ± 6.4 years-13 right, 14 left shoulders) were followed up with CT scans between 2010 and 2012. The analysis of the CT scans (2.4 ± 0.7 months postoperatively) was performed with Osirix™ software. The assessment included two criteria in the axial plane: relation of the graft to the articular surface of the glenoid and impingement of the graft with the maximal humeral head circumference. Grafts were judged to be lateral, congruent, flush or medial. The strength of intra-observer agreement and inter-observer agreement was measured by the Kappa coefficient. The Kappa coefficient for intra-observer agreement was "substantial" (K = 0.64 ± 0.14, z = 4.6) to "almost perfect" (K = 0.81 ± 0.14, z = 5.7). The Kappa coefficient for inter-observer variability was "substantial" (K = 0.59 ± 0.14, z = 4.3) to "almost perfect" (K = 0.89 ± 0.14, z = 6.0). In our study, in the axial plane, 3 (11 %) transplants were lateral; 6 (22 %) transplants were congruent; 16 (60 %) flush and 2 (7 %) medial. This standardized CT scan analysis after Latarjet procedure has shown to accurately describe graft positioning in the axial plane with both good intra-observer reproducibility and inter-observer reproducibility. Case series, treatment study, Level IV.

  2. Autologous Fat Grafting for Whole Breast Reconstruction

    Directory of Open Access Journals (Sweden)

    Benjamin H. L. Howes, MBBS

    2014-03-01

    Full Text Available Summary: This is the first reported case of a patient who had a single-stage large-volume breast reconstruction with autologous fat grafting, following rotation flap approach (RoFA mastectomy. The purpose of this case study was to evaluate the viability of reconstruction of the breast by autologous fat grafting alone, in the context of RoFA mastectomy. The hypothesis was that there would be minimal interval loss of autologous fat on the whole breast reconstruction side. Right RoFA mastectomy was used for resection of an invasive primary breast cancer and resulted in the right breast skin envelope. Eleven months later, the patient underwent grafting of 400 ml of autologous fat into the skin envelope and underlying pectoralis major muscle. Outcome was assessed by using a validated 3D laser scan technique for quantitative breast volume measurement. Other outcome measures included the BREAST-Q questionnaire and 2D clinical photography. At 12-month follow-up, the patient was observed to have maintenance of volume of the reconstructed breast. Her BREAST-Q scores were markedly improved compared with before fat grafting, and there was observable improvement in shape, contour, and symmetry on 2D clinical photography. The 2 new techniques, RoFA mastectomy and large-volume single-stage autologous fat grafting, were used in combination to achieve a satisfactory postmastectomy breast reconstruction. Novel tools for measurement of outcome were the 3D whole-body laser scanner and BREAST-Q questionnaire. This case demonstrates the potential for the use of fat grafting for reconstruction. Outcomes in a larger patient populations are needed to confirm these findings.

  3. Utilization of arterial grafts in foot replantation

    Directory of Open Access Journals (Sweden)

    Selami S. Sirvan, MD

    2017-03-01

    Full Text Available Our subject is a 36-year-old man who presented to the emergency department with bilateral lower extremity amputation at the level of the distal third of the tibia after a car accident. Surgery was planned for below-knee amputation of the right lower extremity and replantation of the left foot. The arteries dissected from the iatrogenically amputated segment were used as grafts to repair vascular gaps during the replantation. The patient's follow-up had been problem free. We concluded that whenever possible, amputated parts unsuitable for replantation should be examined thoroughly and neurovascular structures that might be used as grafts should be preserved.

  4. Utilization of arterial grafts in foot replantation.

    Science.gov (United States)

    Sirvan, Selami S; Dagdelen, Daghan; Akgun Demir, Isil; Cezairlioglu, Mecd Atif; Sezer, Hasan Basri; Karsidag, Semra

    2017-03-01

    Our subject is a 36-year-old man who presented to the emergency department with bilateral lower extremity amputation at the level of the distal third of the tibia after a car accident. Surgery was planned for below-knee amputation of the right lower extremity and replantation of the left foot. The arteries dissected from the iatrogenically amputated segment were used as grafts to repair vascular gaps during the replantation. The patient's follow-up had been problem free. We concluded that whenever possible, amputated parts unsuitable for replantation should be examined thoroughly and neurovascular structures that might be used as grafts should be preserved.

  5. Graft copolimerization of hydrophilic monomers onto irradiated polypropylene fibers

    International Nuclear Information System (INIS)

    Sundardi, F.

    1978-01-01

    A method of graft copolymerization of hydrophilic monomers, such as 1-vinyl-2-pyrrolidone, acrylonitrile, acrylic acid, and acrylamide, onto irradiated polypropylene fibers has been studied. γ ray as well as electron beam were employed for the irradiation processes. Graft-copolymerization kinetics and the properties of grafted fibers have been investigated. Moisture regain, dyes absorption, and melting point of the grafted fibers were found to increase with the increasing of the degree of grafting. Polypropylene for 1-vinyl-2-pyrrolidone grafted fibers showed excellent dye absorption for almost all kinds of dyes such as direct, basic, acid, reactive, disper, and naphthol dyes. However, for polypropylene acrylic acid grafted fibers, the colorfastness to washing was found to be unsatisfactory. The colorfastness to washing for polypropylene 1-vinyl-2-pyrrolidone grafted fibers was found to be fairly good for certain types of dyes such as vat and naphthol dyes. (author)

  6. Tympanoplasty: does dry or wet temporalis fascia graft matter?

    Science.gov (United States)

    Singh, G B; Kumar, D; Aggarwal, K; Garg, S; Arora, R; Kumar, S

    2016-08-01

    To evaluate the success rate of dry and wet temporalis fascia grafts in type I underlay tympanoplasty. A prospective, randomised study was conducted. One hundred adult patients (males and females) with chronic suppurative otitis media (mucosal type) were divided into 2 groups of 50 each: one group underwent dry graft tympanoplasty and the other underwent wet graft tympanoplasty. Fibroblast count was calculated in dry and wet grafts. The dry graft and wet graft groups had overall surgical success rates of 82 and 90 per cent, respectively; this finding was not statistically significant. A statistically significant high fibroblast count was observed in wet grafts, but it did not correlate with surgical success. A dry or wet temporalis fascia graft does not influence the outcome of tympanoplasty type I.

  7. Sulfonated hydrocarbon graft architectures for cation exchange membranes

    DEFF Research Database (Denmark)

    Nielsen, Mads Møller; Jankova Atanasova, Katja; Hvilsted, Søren

    2013-01-01

    A synthetic strategy to hydrocarbon graft architectures prepared from a commercial polysulfone and aimed as ion exchange membrane material is proposed. Polystyrene is grafted from a polysulfone macroinitiator by atom transfer radical polymerization, and subsequently sulfonated with acetyl sulfate...

  8. Lycopene and flesh colour differences in grafted and non-grafted watermelon

    OpenAIRE

    Fekete D.; Stéger-Máté M.; Bőhm V.; Balázs G.; Kappel N.

    2015-01-01

    The experiment was carried out in three regions in Hungary (Jászszentandrás, Cece, Újkígyós) in 2013 to determine the fruit quality of grafted watermelon (Citrullus lanatus Thunb.). The “RX 467” seedless watermelon variety was grafted on two commercial rootstocks “FR STRONG” [Lagenaria siceraria (Mol.) Standl.] and “RS 841” (Cucurbita maxima Duchesne × Cucurbita moschata Duchesne). The lycopene and flesh colours are important quality characteristics even of the selfrooted and grafted watermel...

  9. Cambial Isoperoxidases Related to Graft Compatibility in Pear-Quince Graft Combinations

    OpenAIRE

    GÜLEN*, Hatice

    2005-01-01

    This study was initiated to survey the graft compatibility characteristics of some selected quince clones known as "S.Ö." with regard to isoperoxidase markers. Compatible (Beurre Hardy = BH) and incompatible (Bartlett = BT) pear cultivars were grafted on quince A (QA) and 13 S.Ö. quince clones by T budding. Bark tissues were collected from the union (4, 8 and 12 weeks after grafting) and from unbudded rootstocks in addition to current-year shoots of 2 pear scions to investigate 2 an...

  10. Striatal grafts in a rat model of Huntington's disease

    DEFF Research Database (Denmark)

    Guzman, R; Meyer, M; Lövblad, K O

    1999-01-01

    Survival and integration into the host brain of grafted tissue are crucial factors in neurotransplantation approaches. The present study explored the feasibility of using a clinical MR scanner to study striatal graft development in a rat model of Huntington's disease. Rat fetal lateral ganglionic...... eminences grown as free-floating roller-tube cultures can be successfully grafted in a rat Huntington model and that a clinical MR scanner offers a useful noninvasive tool for studying striatal graft development....

  11. Radiation grafting of dimethylaminopropylacrylamide and dimethylaminopropylmethacrylamide onto polyethylene

    Energy Technology Data Exchange (ETDEWEB)

    Burillo, Guillermina; Oseguera, M.A. [UNAM, Inst. de Ciencias Nucleares, Mexico City (Mexico); Vazquez, Carmen; Castillo, L.P. del [UNAM, Inst. de Investigaciones en Materiales, Mexico City (Mexico)

    1997-11-01

    Radiation-induced grafting of dimethylaminopropylacrylamide and dimethylamino-propylmethacrylamide onto polyethylene films, by direct grafting of the vinyl monomers to a polymer by mutual irradiation, has been investigated. The kinetics of the reaction were studied at different irradiation temperatures, monomer concentration and dose rates of gamma rays, and the appropriate reaction conditions for graft polymerization were determined. The thermal and mechanical behavior of the grafted films by means of DMA, TMA, DSC and TGA were also investigated. (author).

  12. Anterior palatal island advancement flap for bone graft coverage ...

    African Journals Online (AJOL)

    ... Palatal Island Advancement Flap was effective in bone graft coverage in premaxillary edentulous area. Conclusion: It can be used as an aid for bone graft coverage of premaxillary edentulous ridge, where the need for mucosa is small in width but long in length. Keywords: Anterior maxilla, bone graft, dental implant, ...

  13. Bone structure changes in iliac crest grafts combined with implants

    NARCIS (Netherlands)

    Verhoeven, Jan Willem; Ruijter, Jan M.; Koole, Ronald; de Putter, Cornelis; Cune, Marco S.

    2010-01-01

    Remodeling of onlay grafts combined with implants to the mandible results in predictable changes in the graft's radiographic density. We studied the relationship between changes in radiographic density and trabecular structure during the first year after onlay grafting with simultaneous implant

  14. Polymer–clay nanocomposites via chemical grafting of ...

    Indian Academy of Sciences (India)

    The radical polymerization of the product with acrylonitrile (AN) as a vinyl monomer leads to chemical grafting of polyacrylonitrile onto montmorillonite surface. The homopolymer formed during polymerization was separated from the grafted organoclay by Soxhlet extraction. Chemical grafting of the polymer onto Cloisite 20A ...

  15. Defense mechanisms involved in disease resistance of grafted vegetables

    Science.gov (United States)

    Vegetable grafting with resistant rootstocks is an effective strategy to control a variety of soil-borne diseases and root-knot nematodes in the Cucurbitaceae and Solanaceae. In addition, improved resistance to some foliar diseases and viruses has also been reported in grafted plants. Hence, graft...

  16. The Influence of Barrier Membranes on Autologous Bone Grafts

    NARCIS (Netherlands)

    Gielkens, P. F. M.; Schortinghuis, J.; de Jong, J. R.; Paans, A. M. J.; Ruben, J. L.; Raghoebar, G. M.; Stegenga, B.; Bos, R. R. M.

    2008-01-01

    In implant dentistry, there is continuing debate regarding whether a barrier membrane should be applied to cover autologous bone grafts in jaw augmentation. A membrane would prevent graft remodeling with resorption and enhance graft incorporation. We hypothesized that membrane coverage does not

  17. Pressure induced graft-co-polymerization of acrylonitrile onto ...

    Indian Academy of Sciences (India)

    WINTEC

    presence of free radical, a hydrogen atom may be ab- stracted from the cellulose by a growing chain ..... centration of monomer radical per unit volume and hence less grafting takes place. Figure 3. SEM of grafted fibre ... optimum molar ratio for the maximum graft yield has been found to be 0⋅250 : 1. It has been observed ...

  18. Buccal Mucosal Graft for Crippled Hypospadias (Experience in 11 ...

    African Journals Online (AJOL)

    Free buccal mucosal on-lay grafts from the inner aspect of the lower lip were taken for three cases of complicated anterior urethral stricture and for six cases of recurrent urethra-cutaneous fistula after previous multiple penile hypospadias repairs. Nine on-lay free grafts were ventrally placed on the penile urethra. The grafts ...

  19. Aortic Graft Infection: Graphene Shows the Way to an Infection-Resistant Vascular Graft

    Directory of Open Access Journals (Sweden)

    Nikolaos Patelis

    2017-05-01

    Full Text Available Aortic graft infection is a potentially lethal complication of open and endovascular repair of aortic aneurysms. Graphene is the only existing two-dimensional material, and its unique structure gives graphene and its derivatives a plethora of original characteristics. Among other characteristics, graphene demonstrates bacteriostatic and bactericidal effects that could potentially resolve the problem of graft infection in the future. Data already exist in literature supporting this antibacterial effect of graphene oxide and reduced graphene oxide. Combining these materials with other substances enhances the antibacterial effect. Additionally, it looks feasible to expect antibiotic-delivering graphene-based graft materials in the future. Based on already published data, we could conclude that regarding graphene and its derivatives, the blessing of bactericidal effect comes with the curse of human cells toxicity. Therefore, it is important to find a fine balance between the desired antibacterial and the adverse cytotoxic effect before graphene is used in graft materials for humans.

  20. Epidermal grafting versus split-thickness skin grafting for wound healing (EPIGRAAFT): study protocol for a randomised controlled trial

    OpenAIRE

    Kanapathy, Muholan; Hachach-Haram, Nadine; Bystrzonowski, Nicola; Harding, Keith; Mosahebi, Afshin; Richards, Toby

    2016-01-01

    Background Split-thickness skin grafting (SSG) is an important modality for wound closure. However, the donor site becomes a second, often painful wound, which may take more time to heal than the graft site itself and holds the risk of infection and scarring. Epidermal grafting (EG) is an alternative method of autologous skin grafting that harvests only the epidermal layer of the skin by applying continuous negative pressure on the normal skin to raise blisters. This procedure has minimal don...

  1. Grafting functional antioxidants on highly crosslinked polyethylene

    Science.gov (United States)

    Al-Malaika, S.; Riasat, S.; Lewucha, C.

    2016-05-01

    The problem of interference of antioxidants, such as hindered phenols, with peroxide-initiated crosslinking of polyethylene was addressed through the use of functional (reactive) graftable antioxidants (g-AO). Reactive derivatives of hindered phenol and hindered amine antioxidants were synthesised, characterised and used to investigate their grafting reactions in high density polyethylene; both non-crosslinked (PE) and highly peroxide-crosslinked (PEXa). Assessment of the extent of in-situ grafting of the antioxidants, their retention after exhaustive solvent extraction in PE and PEXa, and the stabilising performance of the grafted antioxidants (g-AO) in the polymer were examined and benchmarked against conventionally stabilised crosslinked & non-crosslinked polyethylene. It was shown that the functional antioxidants graft to a high extent in PEXa, and that the level of interference of the g-AOs with the polymer crosslinking process was minimal compared to that of conventional antioxidants which bear the same antioxidant function. The much higher level of retention of the g-AOs in PEXa after exhaustive solvent extraction, compared to that of the corresponding conventional antioxidants, accounts for their superior long-term thermal stabilising performance under severe extractive conditions.

  2. Bud-grafting yellow-poplar

    Science.gov (United States)

    David T. Funk

    1963-01-01

    Several years ago we began work on the vegetative propagation of yellow-poplar (Liriodendron tulipifera L.) with the aim of eventually establishing a clonal seed orchard. We tried field grafting, field budding, and air layering. We then attempted rooting cuttings in the greenhouse and in an indoor propagation bench. The best we could do with any of these methods was 4...

  3. Synthesis and properties of carboxymethylcellulose (CMC) graft ...

    African Journals Online (AJOL)

    Novel biopolymer-based superabsorbent hydrogels were prepared by grafting crosslinked poly (N-vinyl pyrollidin and 2-Acrylamido-2-methyl propan sulfonic acid (PNVP-co-PAMPS) chains onto CMC backbones through a free radical polymerization method. A proposed mechanism for superabsorbent hydrogel formation ...

  4. Fatal Saccharomyces Cerevisiae Aortic Graft Infection

    Science.gov (United States)

    Meyer, Michael (Technical Monitor); Smith, Davey; Metzgar, David; Wills, Christopher; Fierer, Joshua

    2002-01-01

    Saccharomyces cerevisiae is a yeast commonly used in baking and a frequent colonizer of human mucosal surfaces. It is considered relatively nonpathogenic in immunocompetent adults. We present a case of S. cerevisiae fungemia and aortic graft infection in an immunocompetent adult. This is the first reported case of S. cerevisiue fungemia where the identity of the pathogen was confirmed by rRNA sequencing.

  5. Dynamics of solvent-free grafted nanoparticles

    KAUST Repository

    Chremos, Alexandros

    2012-01-01

    The diffusivity and structural relaxation characteristics of oligomer-grafted nanoparticles have been investigated with simulations of a previously proposed coarse-grained model at atmospheric pressure. Solvent-free, polymer-grafted nanoparticles as well as grafted nanoparticles in a melt were compared to a reference system of bare (ungrafted) particles in a melt. Whereas longer chains lead to a larger hydrodynamic radius and lower relative diffusivity for grafted particles in a melt, bulk solvent-free nanoparticles with longer chains have higher relative diffusivities than their short chain counterparts. Solvent-free nanoparticles with short chains undergo a glass transition as indicated by a vanishing diffusivity, diverging structural relaxation time and the formation of body-centered-cubic-like order. Nanoparticles with longer chains exhibit a more gradual increase in the structural relaxation time with decreasing temperature and concomitantly increasing particle volume fraction. The diffusivity of the long chain nanoparticles exhibits a minimum at an intermediate temperature and volume fraction where the polymer brushes of neighboring particles overlap, but must stretch to fill the interparticle space. © 2012 American Institute of Physics.

  6. Surface modification of cellulose by PCL grafts

    International Nuclear Information System (INIS)

    Paquet, Olivier; Krouit, Mohammed; Bras, Julien; Thielemans, Wim; Belgacem, Mohamed Naceur

    2010-01-01

    Two cellulosic substrates (microcrystalline cellulose, MCC, and bleached kraft softwood pulps, BSK) were grafted by polycaprolactone (PCL) chains with different molecular weights, following a three-step procedure using non-swelling conditions in order to limit the reaction to their surface. First, one of the two OH PCL ends was blocked by phenyl isocyanate and the reaction product (adduct 1) was subsequently reacted with 2,4-toluene diisocyanate (adduct 2) to provide it with an NCO function, capable of reacting with cellulose. The ensuing PCL-grafted cellulosic materials were characterized by weight gain, elemental analysis, contact angle measurements, attenuated total reflexion-Fourier transform infrared (ATR-FTIR), X-ray photoelectron spectroscopy (XPS) and biodegradation tests. The modification was proven to occur by the presence of nitrogen atoms in the elemental analysis tests and XPS spectra of modified and soxhlet-extracted cellulose. The contact angle measurements have also shown that the surface became as hydrophobic as PCL itself. The polar component of the surface energy of cellulosic substrates before treatment was found to be about 32 and 10 mJ m -2 , for MCC and BSK, respectively. This value vanished to practically zero after grafting with different PCLs. The strategy proposed in the present work is original since, to the best of our knowledge, this paper reports for the first time the chemical 'grafting onto' of the cellulose surface by PCL macromolecular structures, with the aim of obtaining fibre-matrix co-continuous fully sustainable and biodegradable composite materials.

  7. Cellular grafts in management of leucoderma

    Directory of Open Access Journals (Sweden)

    Mysore Venkataram

    2009-01-01

    Full Text Available Cellular grafting methods constitute important advances in the surgical management of leucoderma. Different methods such as noncultured epidermal suspensions, melanocyte cultures, and melanocyte-keratinocyte cultures have all been shown to be effective. This article reviews these methods.

  8. Graft Copolymerization and Characterization of Styrene with ...

    African Journals Online (AJOL)

    MBI

    2017-05-24

    May 24, 2017 ... (TGA) revealed that the thermal stability of the prepared copolymer is higher than that of chitosan alone. Mw and Mn of the isolated polystyrene from the graft copolymer were found to ... bis-acrylamide was used as the crosslinking agent, leading to the manufacturer of a materials with desirable mechanical ...

  9. BKV-infection in kidney graft dysfunction

    Directory of Open Access Journals (Sweden)

    Juliana Montagner

    Full Text Available INTRODUCTION: BKV nephropathy (BKN causes kidney graft loss, whose specific diagnosis is invasive and might be predicted by the early detection of active viral infection. OBJECTIVE: Determine the BKV-infection prevalence in late kidney graft dysfunction by urinary decoy cell (DC and viral DNA detection in urine (viruria and blood (viremia; active infection. METHODS: Kidney recipients with >1 month follow-up and creatinine >1.5 mg/dL and/or recent increasing >20% (n = 120 had their urine and blood tested for BKV by semi-nested PCR, DC searching, and graft biopsy. PCR-positive patients were classified as 1+, 2+, 3+. DC, viruria and viremia prevalence, sensitivity, specificity, and likelihood ratio (LR were determined (Table 2x2. Diagnosis efficacy of DC and viruria were compared to viremia. RESULTS: DC prevalence was 25%, viruria 61.7%, and viremia 42.5%. Positive and negative patients in each test had similar clinical, immunossupressive, and histopathological characteristics. There was no case of viremia with chronic allograft nephropathy and, under treatment with sirolimus, patients had a lower viruria prevalence (p = 0.043. Intense viruria was the single predictive test for active infection (3+; LR = 2.8.1,6-4,9 CONCLUSION: DC, BKV-viruria and -viremia are commun findings under late kidney graft dysfunction. Viremia could only be predicted by intense viruria. These results should be considered under the context of BKN confirmation.

  10. Impact of bone graft harvesting techniques on bone formation and graft resorption

    DEFF Research Database (Denmark)

    Saulacic, Nikola; Bosshardt, Dieter D; Jensen, Simon S

    2015-01-01

    in the mandibles of 12 minipigs. The animals were sacrificed after 1, 2, 4 and 8 weeks of healing. Histology and histomorphometrical analyses were performed to assess bone formation and graft resorption. An explorative statistical analysis was performed. RESULTS: The amount of new bone increased, while the amount......: Transplantation of autogenous bone particles harvested with four techniques in the present model resulted in moderate differences in terms of bone formation and graft resorption....

  11. Effect of Grafting Method, Graft Cover and Foliar Spray of some Mineral Elements on Persian Walnut Graft-take and Winter Survival Rate

    Directory of Open Access Journals (Sweden)

    Reza Rezaee

    2017-02-01

    Full Text Available Introduction: Persian walnut (Juglans regia L. is an important nut crop in Iran and many parts of the world. One of the major challenges of growing walnut is planting of non-grafted walnut trees in orchards, which leads to the reduction of yield, quality and productivity of walnut orchards. Compared to the other fruit trees, walnut grafting is difficult and even newly grafted walnut seedlings are vulnerable to fall or winter frost chilling, so that most of the seedlings are lost after subjecting to the cold winter. There are a few studies reporting successful grafting in outdoor conditions, however, final grafting take after winter has been usually ignored. Hence, increased walnut grafting success and improved tree growth after grafting through foliar nutrient application may lead to increased tolerance of chilling. Therefore, main goals of this research were to investigate the effect of some graft covers and role of foliar spray of calcium, boron and zinc on the reduction of frost damage in newly grafted seedlings under outdoor conditions. Materials and methods: This research was conducted at agricultural research station, Khoy city, west Azerbaijan province, during 2012-2014. In the first experiment, three methods of grafting including cleft, bark and V-shaped, and two kinds of graft covers including moist sawdust and superabsorbent plus cotton wool were investigated in terms of grafting success and quality of seedlings. In the second experiment, effect of the three above-mentioned grafting methods and two levels of foliar spray including sequential spray of Ca (4 ppm, B and Zn (2% (3 times during growth season and control (no spray were studied in terms of frost damage. The experiments conducted in factorial based on randomized complete block design with 10 trees in each plot. Data were collected 45 days after grafting take, final grafting take after one winter, subsequent scion growth length and diameter and concentration of Ca, B and Zn in

  12. Grafting of methacryl amide onto γ-irradiated silk fiber and several physical properties of the grafted-silk

    International Nuclear Information System (INIS)

    Tsukada, Masuhio; Aoki, Akira

    1985-01-01

    Strength-strain measurement and DSC were carried out in order to analyze the physical properties of Methacryl amide (MAA)-grafted silk fibers, which had been degummed and irradiated with gamma rays (total dose of gamma rays 1.05 Mrad) prior to the MAA graft processing. Strength, elongation, initile tensile resistance and tensile elasticity of MAA-grafted silk fibers were very similar to those of untreated silk fibers. The degree of grafting for MAA-grafted silk was about 40-42 % regardless of gamma irradiation treatment, while the denier of grafted silk was about 30 % greater than that of untreated silk fiber. Water content and humidity absorption power of the silk fiber markedly increased by the MAA grafting. However, strength and elongation of MAA-grafted silk fiber decreased appeciably compared with the untreated silk fiber. Initial tensile resistance and tensile elasticity of MAA-grafted silk fiber remained uncharged even after MAA grafting. Tensile elasticity of MAA-grafted silk fiber which had been irradiated with gamma rays and successively degummed slightly increased with the other MAA-grafted silk fibers. (author)

  13. Synthesis of Polymer Grafted Magnetite Nanoparticle with the Highest Grafting Density via Controlled Radical Polymerization

    Directory of Open Access Journals (Sweden)

    Babu Kothandapani

    2009-01-01

    Full Text Available Abstract The surface-initiated ATRP of benzyl methacrylate, methyl methacrylate, and styrene from magnetite nanoparticle is investigated, without the use of sacrificial (free initiator in solution. It is observed that the grafting density obtained is related to the polymerization kinetics, being higher for faster polymerizing monomer. The grafting density was found to be nearly 2 chains/nm2for the rapidly polymerizing benzyl methacrylate. In contrast, for the less rapidly polymerizing styrene, the grafting density was found to be nearly 0.7 chain/nm2. It is hypothesized that this could be due to the relative rates of surface-initiated polymerization versus conformational mobility of polymer chains anchored by one end to the surface. An amphiphilic diblock polymer based on 2-hydroxylethyl methacrylate is synthesized from the polystyrene monolayer. The homopolymer and block copolymer grafted MNs form stable dispersions in various solvents. In order to evaluate molecular weight of the polymer that was grafted on to the surface of the nanoparticles, it was degrafted suitably and subjected to gel permeation chromatography analysis. Thermogravimetric analysis, transmission electron microscopy, and Fourier transform infrared spectroscopy were used to confirm the grafting reaction.

  14. ATRP grafting from cellulose fibers to create block-copolymer grafts.

    Science.gov (United States)

    Carlmark, Anna; Malmström, Eva E

    2003-01-01

    Cellulose fibers, in the form of a conventional filter paper, have been modified by reacting the hydroxyl groups on the fiber surface with 2-bromoisobutyryl bromide, followed by grafting using ATRP conditions. The papers were first grafted with methyl acrylate (MA), rendering the paper very hydrophobic as reported in an earlier work. The papers were analyzed by gravimetry, FT-IR, ESCA, and AFM. To verify that the polymerization from the surface was "living", a second layer of another, hydrophilic, polymer, 2-hydroxyethyl methacrylate (HEMA), was grafted upon the PMA layer, creating a block-copolymer graft from the fibers. After the layer of PHEMA had been attached, contact angle measurements were no longer possible, because of the absorbing nature of PHEMA-grafted layer. This indicates that a copolymer had indeed been formed on the surface. FT-IR showed a large increase in carbonyl content after the PHEMA-grafting, which further proves that a layer of PHEMA was attached to the PMA layer. This goes to show that the hydrophilic/hydrophobic behavior of a cellulose surface can be tailored by the use of "living"/controlled radical polymerization methods such as ATRP.

  15. Effect of Matching or Overconstraining Knee Laxity During Anterior Cruciate Ligament Reconstruction on Knee Osteoarthritis and Clinical Outcomes: A Randomized Controlled Trial With 84-Month Follow-up.

    Science.gov (United States)

    Akelman, Matthew R; Fadale, Paul D; Hulstyn, Michael J; Shalvoy, Robert M; Garcia, Arlene; Chin, Kaitlyn E; Duryea, Jeffrey; Badger, Gary J; Tung, Glenn A; Fleming, Braden C

    2016-07-01

    The "initial graft tension" applied at the time of graft fixation during anterior cruciate ligament (ACL) reconstruction surgery modulates joint contact mechanics, which in turn may promote posttraumatic osteoarthritis (OA). The study objectives were to compare clinical, functional, patient-reported, and OA imaging outcomes between 2 different initial laxity-based graft tension cohorts and a matched uninjured control group as well as to evaluate the effects of laxity-based graft tension on OA development at 84-month follow-up. The 2 laxity-based tension protocols were (1) to restore normal anteroposterior (AP) laxity at the time of surgery relative to the contralateral uninjured knee (low-tension group) or (2) to overconstrain AP laxity by 2 mm relative to the contralateral uninjured knee (high-tension group). The hypotheses were that (1) the high-tension group would have improved outcomes and decreased OA compared with the low-tension group after 84 months, and (2) the outcomes for the high-tension group would be equivalent to those for an age-, sex-, race-, and activity-matched group of control participants with uninjured knees. Randomized controlled trial; Level of evidence, 1. Patients had their ACLs reconstructed with either a bone-patellar tendon-bone or 4-stranded hamstring autograft, and outcomes were compared with a matched control group. Outcomes were evaluated preoperatively and at 60 and 84 months postoperatively and included clinical (KT-1000 arthrometer AP laxity measurement and International Knee Documentation Committee [IKDC] examination score), functional (1-legged hop for distance and knee extensor torque), patient-reported (Knee injury and Osteoarthritis Outcome Score [KOOS], Short Form-36 [SF-36], and patient satisfaction survey), and OA imaging (measurement of joint space width [JSW], Osteoarthritis Research Society International [OARSI] radiographic score, and Whole-Organ Magnetic Resonance Imaging Score [WORMS]) components. Repeated

  16. Soft tissue grafting to improve implant esthetics

    Directory of Open Access Journals (Sweden)

    Moawia M Kassab

    2010-09-01

    Full Text Available Moawia M KassabDivision of Periodontics, Marquette University, School of Dentistry, Milwaukee, WI, USAAbstract: Dental implants are becoming the treatment of choice to replace missing teeth, especially if the adjacent teeth are free of restorations. When minimal bone width is present, implant placement becomes a challenge and often resulting in recession and dehiscence around the implant that leads to subsequent gingival recession. To correct such defect, the author turned to soft tissue autografting and allografting to correct a buccal dehiscence around tooth #24 after a malpositioned implant placed by a different surgeon. A 25-year-old woman presented with the chief complaint of gingival recession and exposure of implant threads around tooth #24. The patient received three soft tissue grafting procedures to augment the gingival tissue. The first surgery included a connective tissue graft to increase the width of the keratinized gingival tissue. The second surgery included the use of autografting (connective tissue graft to coronally position the soft tissue and achieve implant coverage. The third and final surgery included the use of allografting material Alloderm to increase and mask the implant from showing through the gingiva. Healing period was uneventful for the patient. After three surgical procedures, it appears that soft tissue grafting has increased the width and height of the gingiva surrounding the implant. The accomplished thickness of gingival tissue appeared to mask the showing of implant threads through the gingival tissue and allowed for achieving the desired esthetic that the patient desired. The aim of the study is to present a clinical case with soft tissue grafting procedures.Keywords: case report, connective tissue, dental implants, allograft, coronally positioned flap

  17. Repetitive complications after prosthetic graft for inflammatory aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Yoshihiro Takeda

    2013-11-01

    Full Text Available The presence of retroperitoneal fibrosis after an aortic graft replacement is a marker of poor prognosis following aortic graft replacement. Herein we report the case of a 39-year-old man with retroperitoneal fibrosis that had been causing ureteral obstruction. The man had undergone repeated aortic graft replacement due to bacteremia and aortic graft–small intestinal fistula that occurred 4 years after initial aortic grafting for an inflammatory aortic aneurysm. The patient was discharged after 4 weeks of intravenous antibiotic therapy following the latest aortic graft replacement.

  18. Bone graft viability evaluated by three phase bone scan

    International Nuclear Information System (INIS)

    Ljiljana Jaukovic Rajko Spaic; Marijan Novakovic; Srbislav Stosic

    2004-01-01

    Bone defects resulting war injury can be replaced by microvascular bone grafts from fibula. Aim: The aim of this study was to assess the value of three phase (3P) bone scintigraphy in the early detection of the bone graft complications. Method: 3P bone scans were performed in four patients (two after mandible reconstruction with micro vascular fibular bone grafts, one after fibular transplantation for ulnar and one with humeral reconstruction). First dynamic phase scan was performed immediately after iv injection of 740 MBq Tc- 99m DPD, acquiring 15 two seconds duration frames. Second, early static scan was performed during next 300 seconds, and third, delayed scan three hours later. All scans were obtained under the bone graft region. The scans were evaluated using ROI under graft region and the corresponding contra lateral area. Blood flow in graft region was determined using first phase scan, and tracer uptake in the same region was determined using second and third phase scans. Results: in all patients blood flow in graft region was particularly normal. Tracer uptake in one of two patients with mandible reconstruction was diffusely increased in graft, strongly suggesting infection; In the other patient delayed scan showed no tracer uptake in graft center .Both patients with ulnar and humeral reconstruction showed only slightly decreased tracer uptake in bone grafts. 3 phase bone scintigraphy may play a role in the evaluation of bone graft viability by predicting the infection and necrosis. (authors)

  19. Free and microvascular bone grafting in the irradiated dog mandible

    International Nuclear Information System (INIS)

    Altobelli, D.E.; Lorente, C.A.; Handren, J.H. Jr.; Young, J.; Donoff, R.B.; May, J.W. Jr.

    1987-01-01

    Microvascular and free rib grafts were placed in 4.5 cm defects in an edentate mandibular body defect 18 to 28 days after completion of 50 Gy of irradiation from a 60 Co source. The animals were sacrificed from two to forty weeks postoperatively and evaluated clinically, radiographically, and histologically. There was a marked difference in the alveolar mucosal viability with the two grafts. Mucosal dehiscence was not observed over any of the microvascular grafts, but was present in seven-eighths of the free grafts. Union of the microvascular bone graft to the host bone occurred within six weeks. In contrast, after six weeks the free graft was sequestered in all the animals. An unexpected finding with both types of graft was the marked subperiosteal bone formation. This bone appeared to be derived from the host bed, stabilizing and bridging the defects bilaterally. The results suggest that radiated periosteum may play an important role in osteogenesis

  20. ESR spectroscopic investigations of the radiation-grafting of fluoropolymers

    Energy Technology Data Exchange (ETDEWEB)

    Huebner, G.; Roduner, E. [University of Stuttgart (Germany); Brack, H.P.; Scherer, G.G. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    ESR spectroscopic investigations have clarified the influence of several preparative parameters on the reaction rates and yields obtained in the radiation-grafting method used at PSI to prepare proton-conducting polymer membranes. At a given irradiation dose, a higher concentration of reactive radical sites was detected in ETFE films than in FEP films. This higher concentration explains the higher grafting levels and rates of the ETFE films found in our previous grafting experiments. Taken together, the in-situ ESR experiments and grafting experiments show that the rates of disappearance of radical species and grafting rates and final grafting levels depend strongly on the reaction temperature and the oxygen content of the system. Average grafted chain lengths were calculated to contain about 1,000 monomer units. (author) 2 figs., 4 refs.

  1. Synthesis of graft copolymers onto starch and its semiconducting properties

    Directory of Open Access Journals (Sweden)

    Nevin Çankaya

    Full Text Available Literature review has revealed that, although there are studies about grafting on natural polymers, especially on starch, few of them are about electrical properties of graft polymers. Starch methacrylate (St.met was obtained by esterification of OH groups on natural starch polymer for this purpose. Grafting of synthesized N-cyclohexyl acrylamide (NCA and commercial methyl methacrylate (MMA monomers with St.met was done by free radical polymerization method. The graft copolymers were characterized with FT-IR spectra, thermal and elemental analysis. Thermal stabilities of the graft copolymers were determined by TGA (thermo gravimetric analysis method and thermal stability of the copolymers is decreased via grafting. The electrical conductivity of the polymers was measured as a function of temperature and it has been observed that electrical conductivity increases with increasing temperature. The absorbance and transmittance versus wavelength of the polymers have been measured. Keywords: Starch, Graft copolymer, Semiconducting, Thermal stability, Starch methacrylate

  2. Repair of large segmental bone defects: BMP-2 gene activated muscle grafts vs. autologous bone grafting.

    Science.gov (United States)

    Betz, Oliver B; Betz, Volker M; Schröder, Christian; Penzkofer, Rainer; Göttlinger, Michael; Mayer-Wagner, Susanne; Augat, Peter; Jansson, Volkmar; Müller, Peter E

    2013-08-08

    Common cell based strategies for the treatment of osseous defects require the isolation and expansion of autologous cells. Since this makes such approaches time-consuming and expensive, we developed a novel expedited technology creating gene activated muscle grafts. We have previously shown that large segmental bone defects in rats can be regenerated by implantation of muscle tissue fragments activated by BMP-2 gene transfer. In the present study, we compared the bone healing capacities of such gene activated muscle grafts with bone isografts, mimicking autologous bone grafting, the clinical gold standard for treatment of bone defects in patients. Two of 14 male, syngeneic Fischer 344 rats used for this experiment served as donors for muscle and bone. Muscle tissue was harvested from both hind limbs and incubated with an adenoviral vector carrying the cDNA encoding BMP-2. Bone was harvested from the iliac crest and long bone epiphyses. Bone defects (5 mm) were created in the right femora of 12 rats and were filled with either BMP-2 activated muscle tissue or bone grafts. After eight weeks, femora were evaluated by radiographs, micro-computed tomography (μCT), and biomechanical testing. In the group receiving BMP-2 activated muscle grafts as well as in the bone-grafting group, 100% of the bone defects were healed, as documented by radiographs and μCT-imaging. Bone volume was similar in both groups and biomechanical stability of the two groups was statistically indistinguishable. This study demonstrates that treatment of large bone defects by implantation of BMP-2 gene activated muscle tissue leads to similar bone volume and stability as bone isografts, mimicking autologous bone grafting.

  3. Characterization of N-isopropyl acrylamide/acrylic acid grafted polypropylene nonwoven fabric developed by radiation-induced graft polymerization

    International Nuclear Information System (INIS)

    Kumari, Mamta; Gupta, Bhuvanesh; Ikram, Saiqa

    2012-01-01

    Radiation-induced graft copolymerization of N-isopropylacrylamide (NIPAAm) and acrylic acid (AA) mixture was carried out on polypropylene nonwoven fabric to develop a thermosensitive material and has been found to affect the thermal and physical characteristics of fabric. The grafted fabrics with different monomer ratios were characterized by thermal gravimetric analysis (TGA), fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), X-ray diffraction (XRD), contact angle and atomic force microscopy (AFM). Results of FTIR clearly indicated that poly(acrylic acid) and poly(N-isopropyl acrylamide) were successfully grafted onto the membrane surface. TGA results showed that the thermal stability of PP fabric increased after grafting of NIPAAm/AA. The crystallinity values from DSC and XRD were found to decrease with increase in degree of grafting because of the addition of grafted chains within the noncrystalline region. The decrease in contact angles of the grafted fabric with an increase of the degree of grafting shows that PNIPAAm/PAA exists as the hydrophilic component. The increase in surface roughness after grafting was observed by AFM. - Highlights: ► Grafting of NIPAAm/AA affects the thermal and physical characteristics of fabric. ► Thermal stability of PP fabric increased after grafting of NIPAAm/AA. ► Contact angles of the grafted fabric decrease with an increase of grafting yield. ► PNIPAAm/PAA was found to exist as the hydrophilic component. ► AFM images showed that there is an increase in surface roughness after grafting.

  4. Gold nanoparticles grafting on glass surface

    Science.gov (United States)

    Kvítek, Ondřej; Bot, Marek; Švorčík, Václav

    2012-09-01

    New method of grafting of gold nanoparticles (AuNPs) to glass surface was developed and investigated. The method based on glass activation by plasma discharge use dithiols for AuNP binding as an alternative to silane chemistry currently used for binding AuNPs onto glass surface. XPS measurements confirmed the presence of sulfur and gold on the modified glass surface. The presence of AuNPs on modified glass surface was then directly proven with AFM method. UV-vis spectra of samples with grafted AuNPs show a peak of SPR absorbance. With increasing modification time, more AuNPs are bound to the glass surface, which can aggregate.

  5. Autologous Fat Grafting Improves Facial Nerve Function

    Directory of Open Access Journals (Sweden)

    Marco Klinger

    2015-01-01

    Full Text Available We describe the case of a 45-year-old male patient who presented a retractile and painful scar in the nasolabial fold due to trauma which determined partial motor impairment of the mouth movements. We subsequently treated him with autologous fat grafting according to Coleman’s technique. Clinical assessments were performed at 5 and 14 days and 1, 3, and 6 months after surgical procedure and we observed a progressive release of scar retraction together with an important improvement of pain symptoms. A second procedure was performed 6 months after the previous one. We observed total restoration of mimic movements within one-year follow-up. The case described confirms autologous fat grafting regenerative effect on scar tissue enlightening a possible therapeutic effect on peripheral nerve activity, hypothesizing that its entrapment into scar tissue can determine a partial loss of function.

  6. Osseous-Cartilaginous Spreader Graft and Nasal Framework Reconstruction.

    Science.gov (United States)

    Ors, Safvet

    2017-10-01

    Revision rhinoplasties and saddle nose deformities usually require grafting for reconstruction. Between January 1, 2000, and January 1, 2017, autologous rib grafts were used in 127 secondary and tertiary rhinoplasty patients [(57/127 females) and (70/127 males)]. Osseous-cartilaginous rib grafts (OCRGs) were divided into three parts (i.e., 1/3 upper peripheral, 1/3 central, and 1/3 lower peripheral). The harvested OCRGs were also shaped as vertical strips using a number 11 scalpel blade. These OCRGs were shaped to form the L-strut cartilaginous graft (LSCGs), osseous-cartilaginous spreader grafts (OCSGs), osseous-cartilaginous onlay grafts, nasal valve grafts (NVGs), and lower lateral cartilaginous grafts (LLCGs). The upper peripheral portion of the rib was usually used as an onlay graft for dorsal reshaping. The shape of this part was minimally convex after being cut from the main graft, and the convex shape was very appropriate for use as an onlay graft. The middle portion of the graft that consisted of the osseous and cartilaginous structure was used for the OCSGs. The middle portion of the graft that contained only cartilage was used for the LSCGs, NVGs, and LLCGs. OCRGs were used for the dorsal, alar, septal, upper lateral, and columellar struts for all patients. OCSGs were used for all of the septal grafts to provide further stability. In the nasal valve failure patients, the rib cartilage was fixed onto the lower lateral and upper lateral cartilage and was sutured using polyglactin to improve nasal valve function. One edge of the graft was sutured over the septum, and the other edge was positioned against the maxillary crest to allow for air flow at the nasal valve. After an OCSG was sutured to the septum, a flat and smooth dorsum was shaped before the dorsal onlay graft was placed and fixed. The bone fragments of the grafts that consisted of spreader and onlay grafts were tied to the radix nasi bone without any space. After 6 months of follow-up, a

  7. Modification of polyetherurethane for biomedical application by radiation-induced grafting. I. Grafting procedure, determination of mechanical properties, and chemical modification of grafted films

    International Nuclear Information System (INIS)

    Jansen, B.; Ellinghorst, G.

    1985-01-01

    Radiation grafting of monomers onto suitable trunk polymers is a useful tool for tailoring new polymers for special purposes. This technique has been used in the past for the development of biocompatible materials, e.g., by grafting hydrogels onto mechanically stable polymers. In this first part of our work, the radiation grafting of hydrophilic or reactive monomers onto a polyetherurethane film using the pre-swelling technique is described. Following this technique the trunk polymer was swollen in the monomer before irradiation. As monomers 2-hydroxyethyl methacrylate (HEMA), 2,3-epoxypropyl methacrylate (GMA), 2,3-dihydroxypropyl methacrylate (GOMA), and acrylamide (AAm) were used. The kinetics of the grafting reactions were examined, and the distribution of the graft component inside the trunk polymer was investigated by means of infrared (IR) spectroscopy. Surface-grafted as well as bulk- and surface-grafted products could be obtained. The mechanical behavior of the grafted films--especially in the water-swollen state--was examined and compared with that of the pure trunk polymer. In nearly all cases it was found that the tensile strength sigma B and the elongation at break epsilon R decreases as the grafting yield increases. Modification of GMA- and AAm-grafted films via chemical reactions was performed to create new functional groups of biomedical interest. In this manner a diol structure, a carboxylic acid structure, and a sulfonic acid group could be introduced in the grafted polymer. The water uptake of such modified films is increased markedly when compared with that of the unmodified samples

  8. LATE RENAL GRAFT REJECTION: PATHOLOGY AND PROGNOSIS

    Directory of Open Access Journals (Sweden)

    E.S. Stolyarevich

    2014-01-01

    Full Text Available Rejection has always been one of the most important cause of late renal graft dysfunction. Aim of the study was to analyze the prevalence of different clinico-pathological variants of rejection that cause late graft dysfunction, and evaluate their impact on long-term outcome. Materials and methods. This is a retrospective study that analyzed 294 needle core biopsy specimens from 265 renal transplant recipients with late (48,8 ± 46,1 months after transplantation allograft dysfunction caused by late acute rejection (LAR, n = 193 or chronic rejection (CR, n = 78 or both (n = 23. C4d staining was performed by immunofl uorescence (IF on frozen sections using a standard protocol. Results. Peritubular capillary C4d deposition was identifi ed in 36% samples with acute rejection and in 62% cases of chronic rejection (including 67% cases of transplant glomerulopathy, and 50% – of isolated chronic vasculopathy. 5-year graft survival for LAR vs CR vs their combination was 47, 13 and 25%, respectively. The outcome of C4d– LAR was (p < 0,01 better than of C4d+ acute rejection: at 60 months graft survival for diffuse C4d+ vs C4d− was 33% vs 53%, respectively. In cases of chronic rejection C4d+ vs C4d– it was not statistically signifi cant (34% vs 36%. Conclusion. In long-term allograft biopsy C4d positivity is more haracteristic for chronic rejection than for acute rejection. Only diffuse C4d staining affects the outcome. C4d– positivity is associated with worse allograft survival in cases of late acute rejection, but not in cases of chronic rejection. 

  9. Graft selection in anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Miller, Suzanne L; Gladstone, James N

    2002-10-01

    Selecting the appropriate graft for ACL reconstruction depends on numerous factors including surgeon philosophy and experience, tissue availability (affected by anatomical anomalies or prior injury or surgery), and patient activity level and desires. Although the patella tendon autograft has the widest experience in the literature, and is probably the most commonly used graft source, this must be tempered with the higher reported incidences of potential morbidity and pitfalls associated with its use. The hamstring tendons are gaining increasing popularity, mostly due to reduced harvest morbidity and improved soft tissue fixation techniques, and many recent studies in the literature report equal results to BTB ACL reconstruction with respect to functional outcome and patient satisfaction. On the other hand, many of these studies report higher degrees of instrument (KT-100) tested laxity for hamstring reconstruction, and some have reported lower returns to preinjury levels of activity. One question that remains to be addressed is how closely objectively measured laxity tests correlate with subjectively assessed outcomes and ability to return to high levels of competitive sports. Allograft use, which decreased in popularity during the 1990s, appears to be undergoing a resurgence, with better sterilization processes and new graft sources (tibialis tendons), leading to increased availability and improved fixation techniques. The benefits of decreased surgical morbidity and easier rehabilitation must be weighed against the potential for greater failure of biologic incorporation, infection, and possibly slower return to activities. In our practice, for high-demand individuals (those playing cutting, pivoting, or jumping sports and skiing) BTB tends to be the graft of choice. For lower demand or older individuals, hamstring reconstructions will be performed. Allograft tissue will be used in older individuals (generally over 45 years old), those with signs of arthritis (and

  10. Split-thickness skin grafting: early outcomes of a clinical trial using different graft thickness.

    Science.gov (United States)

    Guogienė, Inga; Kievišas, Mantas; Grigaitė, Augustina; Braziulis, Kęstutis; Rimdeika, Rytis

    2018-01-02

    In clinical practice, split-thickness skin graft (STSG) transplantation remains the gold standard for covering large skin defects. Currently, there is no consensus on the optimal thickness of skin grafts. The purpose of our study was to compare the early healing processes of recipient and donor wounds after STSG transplantation using grafts of different thickness. This prospective, randomised clinical trial included 84 patients that underwent STSG transplantation surgery for post-burn, post-traumatic or postoperative skin defects. Patients were randomised to receive a skin graft of either 0.2mm, 0.3mm or 0.4mm thickness. After skin transplantation, the wound healing parameters of both the recipient and donor wounds were evaluated after three days, one week, two weeks and one month. The greatest mean epithelialisation scores and highest rate of complete wound epithelialisation were identified in the recipient and donor wounds of the 0.2mm transplant group, at all time points. When the recipient wound pain scores were evaluated, the greatest visual analogue scale (VAS) values were found in the 0.2mm transplant group. The opposite result was found for the donor wound, where the highest VAS scores were identified in the 0.4mm transplant group. There were no significant differences, at any follow-up period, when wound secretion, erythema, swelling, localised warmth and fluctuation were compared. The early healing of recipient wounds after STSG transplantation with grafts of various thickness differed considerably, especially regarding wound epithelialisation and pain.

  11. Hydrogen, a potential safeguard for graft-versus-host disease and graft ischemia-reperfusion injury?

    Science.gov (United States)

    Yuan, Lijuan; Shen, Jianliang

    2016-01-01

    Post-transplant complications such as graft-versus-host disease and graft ischemia-reperfusion injury are crucial challenges in transplantation. Hydrogen can act as a potential antioxidant, playing a preventive role against post-transplant complications in animal models of multiple organ transplantation. Herein, the authors review the current literature regarding the effects of hydrogen on graft ischemia-reperfusion injury and graft-versus-host disease. Existing data on the effects of hydrogen on ischemia-reperfusion injury related to organ transplantation are specifically reviewed and coupled with further suggestions for future work. The reviewed studies showed that hydrogen (inhaled or dissolved in saline) improved the outcomes of organ transplantation by decreasing oxidative stress and inflammation at both the transplanted organ and the systemic levels. In conclusion, a substantial body of experimental evidence suggests that hydrogen can significantly alleviate transplantation-related ischemia-reperfusion injury and have a therapeutic effect on graft-versus-host disease, mainly via inhibition of inflammatory cytokine secretion and reduction of oxidative stress through several underlying mechanisms. Further animal experiments and preliminary human clinical trials will lay the foundation for hydrogen use as a drug in the clinic. PMID:27652837

  12. The effect of carbon dioxide therapy on composite graft survival.

    Science.gov (United States)

    Durães, Eliana Ferreira Ribeiro; Durães, Leonardo de Castro; Carneiro, Fabiana Pirani; Lino, Ruy de Souza; Sousa, João Batista de

    2013-08-01

    To investigate the effect of carboxytherapy in auricular composite grafts in rabbits. An experimental study was conducted using 20 rabbits randomly assigned to a treatment group of carboxytherapy or a control group of saline solution. In each ear, a circular graft with 1.5 cm or 2 cm of diameter was amputated and reattached. Animals underwent carbon dioxide or saline injection four times during the experiment. We analyzed clinical evolution of the animals, grafts survival, histopathology features and histomorphometry of collagen. The treated group had a significantly lower weight gain (p=0.038). Histopathology was not significantly different between groups. There was an increase in amount of collagen in 2 cm grafts submitted to carbon dioxide therapy (p=0.003). Carboxytherapy didn't influence graft survival rate for 1.5 cm grafts or 2 cm grafts (p=0.567 and p=0.777, respectively). Carbon dioxide therapy increased the amount of collagen in 2 cm grafts. CO2 was not significantly different from saline infusion on composite grafts survival, but this study suggests that there is a mechanical effect caused by distension which favored graft survival.

  13. GRAFT TAKES OF TOMATO ON OTHER SOLANACEOUS PLANTS

    Directory of Open Access Journals (Sweden)

    ANDRÉ RICARDO ZEIST

    2017-01-01

    Full Text Available This paper aimed to assess tomato grafting on different solanaceous species through two grafting methods. Scions were cut from cultivar Santa Cruz Kada seedlings. A fully randomized experimental design was carried out with treatments in a 9 x 2 factorial scheme. As rootstocks, four accessions of mini - tomatoes (0224 - 53, RVTC 57, RVTC 20 and 6889 - 50 - Solanum lycopersicum L; two species of wild tomato ( Solanum habrochaites var hirsutum ‘PI - 127826’ and Solanum pennellii ‘LA716’; other two tomato species [ Solanum, cocona ( Solanum sessiliflorum and physalis ( Physalis peruviana ] and a control with cultivar Santa Cruz Kada (auto - graft rootstocks were used. In addition, two grafting methods were evaluated full cleft and approach graft. Fifteen days after grafting, plants were assessed for graft - take percentage; root length; plant height; leaf number; foliar area; root, stem and leaf dry matter; and ratio between shoot and root dry matter. Based on the results, we may state rootstock and grafting interaction had effect on both graft - take rate and plant development. Overall, the studied plants should be recommended as rootstock, except for 6889 - 50 mini - tomato ( S. lycopersicum L. and S. pennellii . Full cleft grafting was most suitable for cocona and physalis, while the approach method showed better results for the mini - tomato accessions 0224 - 53, RVTC 57 and RVTC 20, as well as for S. habrochaites .

  14. Calcification of a Synthetic Renovascular Graft in a Child

    Directory of Open Access Journals (Sweden)

    D.S.T. Chong

    Full Text Available : Introduction: Vascular grafts, especially in paediatric cases, need to be durable. Common failures such as thrombosis are well documented with research efforts directed towards them. However, there are lesser known causes of graft failure, such as graft calcification, and these also require further research focus. Report: A paediatric case is described in which a synthetic renovascular graft, implanted for mid-aortic syndrome, became calcified, necessitating surgical intervention to resolve graft malfunction. Significant calcification in the limb of a bifurcated polyethylene terephthalate graft was found to be the cause of resistant stenosis and refractory hypertension. Histology conducted on the explanted limb showed the presence of multinuclear giant cells, indicating a chronic foreign body response. Discussion: Calcification of vascular grafts is probably more common than previously recognised. Stenosis typically resistant to angioplasty may result in the long term and thus leading to surgical intervention. In young children, this is suboptimal as these grafts need to last throughout adulthood. Explanted prosthetic grafts should be sent to specialist registries such as that in Strasbourg to be optimally assessed so that contributory factors can be identified. Keywords: Renovascular graft, Paediatric, Calcification

  15. A multilayered polyurethane foam technique for skin graft immobilization.

    Science.gov (United States)

    Nakamura, Motoki; Ito, Erika; Kato, Hiroshi; Watanabe, Shoichi; Morita, Akimichi

    2012-02-01

    Several techniques are applicable for skin graft immobilization. Although the sponge dressing is a popular technique, pressure failure near the center of the graft is a weakness of the technique that can result in engraftment failure. To evaluate the efficacy of a new skin graft immobilization technique using multilayered polyurethane foam in vivo and in vitro. Twenty-six patients underwent a full-thickness skin graft. Multiple layers of a hydrocellular polyurethane foam dressing were used for skin graft immobilization. In addition, we created an in vitro skin graft model that allowed us to estimate immobilization pressure at the center and edges of skin grafts of various sizes. Overall mean graft survival was 88.9%. In the head and neck region (19 patients), mean graft survival was 93.6%. Based on the in vitro outcomes, this technique supplies effective pressure (polyurethane foam dressing is simple, safe, and effective for skin graft immobilization. © 2011 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  16. Dynamic, nondestructive imaging of a bioengineered vascular graft endothelium.

    Directory of Open Access Journals (Sweden)

    Bryce M Whited

    Full Text Available Bioengineering of vascular grafts holds great potential to address the shortcomings associated with autologous and conventional synthetic vascular grafts used for small diameter grafting procedures. Lumen endothelialization of bioengineered vascular grafts is essential to provide an antithrombogenic graft surface to ensure long-term patency after implantation. Conventional methods used to assess endothelialization in vitro typically involve periodic harvesting of the graft for histological sectioning and staining of the lumen. Endpoint testing methods such as these are effective but do not provide real-time information of endothelial cells in their intact microenvironment, rather only a single time point measurement of endothelium development. Therefore, nondestructive methods are needed to provide dynamic information of graft endothelialization and endothelium maturation in vitro. To address this need, we have developed a nondestructive fiber optic based (FOB imaging method that is capable of dynamic assessment of graft endothelialization without disturbing the graft housed in a bioreactor. In this study we demonstrate the capability of the FOB imaging method to quantify electrospun vascular graft endothelialization, EC detachment, and apoptosis in a nondestructive manner. The electrospun scaffold fiber diameter of the graft lumen was systematically varied and the FOB imaging system was used to noninvasively quantify the affect of topography on graft endothelialization over a 7-day period. Additionally, results demonstrated that the FOB imaging method had a greater imaging penetration depth than that of two-photon microscopy. This imaging method is a powerful tool to optimize vascular grafts and bioreactor conditions in vitro, and can be further adapted to monitor endothelium maturation and response to fluid flow bioreactor preconditioning.

  17. Allogeneic bone marrow grafts in genotyped swine

    International Nuclear Information System (INIS)

    Vaiman, M.

    1974-01-01

    The proof of a major histocompatibility complex (MHC) called SL-A enabled to promote bone marrow allografts. A study of the response to that kind of graft in irradiated pig states a number of interesting points. Bone marrow allografting complies with the rule of tissular compatibility with the major histocompatibility complex. The taking of SL-A incompatible bone marrow allografts could not be achieved under the experimental conditions. In spite of the high doses of radiation, 950 to 1050 rads, higher than 1.5 LD 100%, recipients were capable of rejecting their grafts, regularly. SL-A identify ensured 100%, initial achievement. However, animals developed regular fatal disease within a fairly short time. This development could by no means, be ascribed to the sole sequealae of radiation sickness since autografted animals at equal or even higher doses, showed none of the symptome. Assumption of a chronic graft-vs-host reactions, induced by the minor histocompatible systems, was put foreward, but should be confirmed histopathologically [fr

  18. Transabdominal sacrocolpopexy with autologous rectus fascia graft.

    Science.gov (United States)

    Abraham, Nitya; Quirouet, Adrienne; Goldman, Howard B

    2016-08-01

    Extrusion and infection are potential postoperative complications when using synthetic mesh for abdominal sacrocolpopexy. Long-term follow-up in the Colpopexy and Urinary Reduction Efforts (CARE) trial revealed an estimated 9.9 % risk of mesh extrusion. There are 26 reports of spondylodiscitis after sacrocolpopexy with synthetic mesh. These surgical risks may be decreased by using autologous fascia. To date, there have been no reports of extrusion or spondylodiscitis after using autologous fascia for sacrocolpopexy. This video demonstrates transabdominal sacrocolpopexy with an autologous rectus fascia graft. A 76-year-old woman with symptomatic stage 3 prolapse also had a history of diverticulitis and sigmoid abscess requiring sigmoid colectomy with end colostomy and incidental left ureteral transection with subsequent left nephrostomy tube placement. She presented for colostomy reversal, ureteral reimplantation, and prolapse repair. Given the need for concomitant colon and ureteral reconstruction, the risk of infection was potentially higher if synthetic mesh were used. The patient therefore underwent transabdominal sacrocolpopexy with autologous rectus fascia graft. At 4 months' follow-up the patient reported resolution of her symptoms and on examination she had no pelvic organ prolapse. Transabdominal sacrocolpopexy using autologous rectus fascia graft is a feasible option, especially in cases in which infection and synthetic mesh extrusion risks are potentially higher.

  19. Ion exchange fiber by radiation grafting, 1

    International Nuclear Information System (INIS)

    Fujiwara, Kunio

    1990-01-01

    Radiation grafting is gaining attention as a method for producing high performance materials. This method can be applied to add functions to existing polymer plastics. The author participated in the research program on the production of ion exchange fiber by radiation grafting and its applicability at the Japan Atomic Energy Research Institute, Takasaki Radiation Chemistry Research Establishment. Consequently, it was clarified that it was possible to introduce the cation exchange group, represented by sulfonic and carboxyl groups, and the anion exchange group, represented by the quarternary ammonium group, to polypropylene fiber available on the market. The ion exchange capacity was able to be controlled by the degree of grafting, i.e. approximately up to 3 meq/g in both strong acid and strong base and approximately up to 5 meq/g in weak acid were obtained. The adsorption performance of ammonia, a representative malodorous substance, was also studied using test cation exchange fiber. The adsorption rate of H type strong acid cation exchange fiber was great, due to the H type having neutral reaction, and the adsorption capacity matched the ion exchange capacity. Although the Cu and Ni types features coordinated adsorption and their adsorption rates were from 1/2 to 1/3 of that of the H type, their adsorption capacities showed increase along with the metal adsorbed. (author)

  20. Graft fixation in cruciate ligament reconstruction.

    Science.gov (United States)

    Brand, J; Weiler, A; Caborn, D N; Brown, C H; Johnson, D L

    2000-01-01

    Cruciate ligament reconstruction has progressed dramatically in the last 20 years. Anatomic placement of ligament substitutes has fostered rehabilitation efforts that stress immediate and full range of motion, immediate weightbearing, neuromuscular strength and coordination, and early return to athletic competition (3 months). This has placed extreme importance on secure graft fixation at the time of ligament reconstruction. Current ligament substitutes require a bony or soft tissue component to be fixed within a bone tunnel or on the periosteum at a distance from the normal ligament attachment site. Fixation devices have progressed from metal to biodegradable and from far to near-normal native ligament attachment sites. Ideally, the biomechanical properties of the entire graft construct would approach those of the native ligament and facilitate biologic incorporation of the graft. Fixation should be done at the normal anatomic attachment site of the native ligament (aperture fixation) and, over time, allow the biologic return of the histologic transition zone from ligament to fibrocartilage, to calcified fibrocartilage, to bone. The purpose of this article is to review current fixation devices and techniques in cruciate ligament surgery.

  1. Research of Customized Aortic Stent Graft Manufacture

    Science.gov (United States)

    Zhang, Lei; Chen, Xin; Liu, Muhan

    2017-03-01

    Thoracic descending aorta diseases include aortic dissection and aortic aneurysm, of which the natural mortality rate is extremely high. At present, endovascular aneurysm repair (EVAR) has been widely used as an effective means for the treatment of descending aortic disease. Most of the existing coating stents are standard design, which are unable to meet the size or structure of different patients. As a result, failure of treatment would be caused by dimensional discrepancy between stent and vessels, which could lead to internal leakage or rupture of blood vessels. Therefore, based on rapid prototyping sacrificial core - coating forming (RPSC-CF), a customized aortic stent graft manufactured technique has been proposed in this study. The aortic stent graft consists of film and metallic stent, so polyether polyurethane (PU) and nickel-titanium (NiTi) shape memory alloy with good biocompatibility were chosen. To minimum film thickness without degrading performance, effect of different dip coating conditions on the thickness of film were studied. To make the NiTi alloy exhibit super-elasticity at body temperature (37°C), influence of different heat treatment conditions on austenite transformation temperature (Af) and mechanical properties were studied. The results show that the customized stent grafts could meet the demand of personalized therapy, and have good performance in blasting pressure and radial support force, laying the foundation for further animal experiment and clinical experiment.

  2. Vascularized nerve grafts: an experimental study.

    Science.gov (United States)

    Donzelli, Renato; Capone, Crescenzo; Sgulò, Francesco Giovanni; Mariniello, Giuseppe; Maiuri, Francesco

    2016-08-01

    The aim of this study is to define an experimental model in order to promote the functional recovery of the nerves using grafts with vascular support (Vascular Nerve Grafts - VNG). The aim of this study is to define, on an experimental model in normal recipient bed, whether the functional recovery with VNG is superior to that obtained non-vascularized graft (NNG). Twenty male rabbits, which underwent dissection of sciatic nerve, were later treated by reinnervation through an autograft. In 10 animals the reconstruction of sciatic nerve was realized with VNG; in 10 control animals the reconstruction of sciatic nerve was realized with NNG. The VNG group showed a better axonal organization and a significantly higher number of regenerated axons in the early phases (after 30 days) than the NNG group, whereas the difference in the axonal number at day 90 was less significant; besides, the axon diameter and the myelin thickness were not significantly improved by VNG group. Our data suggests that the use of VNG leads to a faster regeneration process and a better functional recovery, although the final results are comparable to those of the NNG. VNG improve the quality of the axonal regeneration (axonal diameter and Schwann cells), although the increase in the axonal number is not significant and does not improve the long-term functional outcome.

  3. Allogenic lyophilized cartilage grafts for craniomaxillofacial reconstruction

    International Nuclear Information System (INIS)

    Pill Hoon Choung

    1999-01-01

    Allogenic lyophilized cartilages were made in our clinic after Sailer methods and some modification. In our clinic, we have used allogenic cartilage grafts on 102 defects of craniomaxillofacial area; 1) for defects from cyst or ameloblastoma, 2) for lack of continuity of the mandible, 3) for rhinoplasty, 4) for paranasal augmentation, 5) for augmentation genioplasty, 6) for reconstruction of orbital floor, 7) for oroantral fistula, 8) for temporal augmentation, 9) for TMJ surgery 10) for condyle defect as a costochondral graft, 11) for filling of tooth socket and alveolus augmentation,12) for correction or orbital height and 13) for guided bone regeneration in peripheral implant. The types of lyophilized cartilage used were chip, sheet and block types developed by freeze-dried methods. Some grafts showed change of ossification, in which case we could perform implant on it. We have good results on reconstruction of craniomaxillofacial defects. Allogenic cartilage have advantages such as 1) it has no immune reaction clinically, 2) it is more tolerable to infection than that of autogenous cartilage, 3) it has character of less resorption which require no over correction, 4) it is easy to manipulate contouring, and 5) it has possibility of undergoing ossification. Allogenic cartilage has been considered as good substitutes for bone. The author would like to report the results on 102 allogenic cartilage have

  4. Does Anteromedial Portal Drilling Improve Footprint Placement in Anterior Cruciate Ligament Reconstruction?

    Science.gov (United States)

    Arno, Sally; Bell, Christopher P; Alaia, Michael J; Singh, Brian C; Jazrawi, Laith M; Walker, Peter S; Bansal, Ankit; Garofolo, Garret; Sherman, Orrin H

    2016-07-01

    Considerable debate remains over which anterior cruciate ligament (ACL) reconstruction technique can best restore knee stability. Traditionally, femoral tunnel drilling has been done through a previously drilled tibial tunnel; however, potential nonanatomic tunnel placement can produce a vertical graft, which although it would restore sagittal stability, it would not control rotational stability. To address this, some suggest that the femoral tunnel be created independently of the tibial tunnel through the use of an anteromedial (AM) portal, but whether this results in a more anatomic footprint or in stability comparable to that of the intact contralateral knee still remains controversial. (1) Does the AM technique achieve footprints closer to anatomic than the transtibial (TT) technique? (2) Does the AM technique result in stability equivalent to that of the intact contralateral knee? (3) Are there differences in patient-reported outcomes between the two techniques? Twenty male patients who underwent a bone-patellar tendon-bone autograft were recruited for this study, 10 in the TT group and 10 in the AM group. Patients in each group were randomly selected from four surgeons at our institution with both groups demonstrating similar demographics. The type of procedure chosen for each patient was based on the preferred technique of the surgeon. Some surgeons exclusively used the TT technique, whereas other surgeons specifically used the AM technique. Surgeons had no input on which patients were chosen to participate in this study. Mean postoperative time was 13 ± 2.8 and 15 ± 3.2 months for the TT and AM groups, respectively. Patients were identified retrospectively as having either the TT or AM Technique from our institutional database. At followup, clinical outcome scores were gathered as well as the footprint placement and knee stability assessed. To assess the footprint placement and knee stability, three-dimensional surface models of the femur, tibia, and ACL

  5. CMR diagnosis of coronary graft fistula

    Directory of Open Access Journals (Sweden)

    Bengt Johansson

    2014-01-01

    Full Text Available The patient is a 54-year old man with a previous history of cerebral aqueduct stenosis and hydrocephalus resulting in malignant hypertension who had surgery for permanent ventriculo-peritoneal shunt. At age 41, he had coronary artery bypass graft (CABG surgery with the right internal mammary artery anastomosed to the posterior descending artery and a saphenous vein graft to the first obtuse marginal branch. The patient was recently admitted with pneumonia that rapidly deteriorated and he went in respiratory failure requiring mechanical ventilation. A thoracic CT investigation showed massive bilateral pulmonary infiltrates, pulmonary artery embolism and a large vein graft aneurysm with a maximal diameter of 40 mm (Figure 1 A-B. The management course was complicated with prolonged respiratory failure, persistent infection, despite negative cultures and extended hospital stay. After 50 days of slow recovery the patient was discharged with a need for home oxygen therapy. Ten days later, he was re-admitted with chest pain requiring admission to the coronary care unit where severe pulmonary hypertension was diagnosed with Doppler echocardiography. Troponin-T was mildly elevated, 1,3 ug/L (ref <0,01, CRP was 50 mg/L and chest X-ray showed bilateral lung infiltrates and wide pulmonary vessels. At this point a systo-diastolic murmur was heard at the left lower sternal edge. With a view of potential coronary reintervention and to evaluate the pulmonary hypertension, a coronary angiogram and a pulmonary artery cathetherisation were performed. This showed a new stenosis in the left anterior descending coronary artery and the pulmonary catheterisation showed a “step-up” in oxygen saturation in the pulmonary artery, suggesting a left-to-right shunt. The vein graft aneurysm did not contribute to the coronary circulation. A cardiovascular magnetic resonance scan revealed a communication between the vein graft aneurysm and the left branch pulmonary artery

  6. Sagittal Alignment of a Strut Graft Affects Graft Subsidence and Clinical Outcomes of Anterior Cervical Corpectomy and Fusion.

    Science.gov (United States)

    Yamauchi, Koun; Fushimi, Kazunari; Miyamoto, Kei; Hioki, Akira; Shimizu, Katsuji; Akiyama, Haruhiko

    2017-10-01

    Retrospective study. The purpose of this study was to investigate the influence of sagittal alignment of the strut graft on graft subsidence and clinical outcomes after anterior cervical corpectomy and fusion (ACCF). ACCF is a common technique for the treatment of various cervical pathologies. Although graft subsidence sometimes occurs after ACCF, it is one cause for poor clinical results. Malalignment of the strut graft is probably one of the factors associated with graft subsidence. However, to the best of our knowledge, no prior reports have demonstrated correlations between the alignment of the strut graft and clinical outcomes. We evaluated 56 patients (33 men and 23 women; mean age, 59 years; range, 33-84 years; 45 with cervical spondylotic myelopathy and 11 with ossification of the posterior longitudinal ligament) who underwent one- or two-level ACCF with an autogenous fibular strut graft and anterior plating. The Japanese Orthopaedic Association (JOA) score recovery ratio for cervical spondylotic myelopathy was used to evaluate clinical outcomes. The JOA score and lateral radiograms were evaluated 1 week and 1 year postoperatively. Patients were divided into two groups (a straight group [group I] and an oblique group [group Z]) based on radiographic assessment of the sagittal alignment of the strut graft. Group I showed a significantly greater JOA score recovery ratio ( p subsidence than group Z ( p subsidence after ACCF. In contrast, an oblique strut graft can lead to significantly increased strut graft subsidence and poor clinical results.

  7. Tuning the Mechanical Properties of Polymer Nanocomposites Filled with Grafted Nanoparticles by Varying the Grafted Chain Length and Flexibility

    Directory of Open Access Journals (Sweden)

    Zixuan Wang

    2016-08-01

    Full Text Available By employing coarse-grained molecular dynamics simulation, we simulate the spatial organization of the polymer-grafted nanoparticles (NPs in homopolymer matrix and the resulting mechanical performance, by particularly regulating the grafted chain length and flexibility. The morphologies ranging from the agglomerate, cylinder, sheet, and string to full dispersion are observed, by gradually increasing the grafted chain length. The radial distribution function and the total interaction energy between NPs are calculated. Meanwhile, the stress–strain behavior of each morphology and the morphological evolution during the uniaxial tension are simulated. In particular, the sheet structure exhibits the best mechanical reinforcement compared to other morphologies. In addition, the change of the grafted chain flexibility to semi-flexibility leads to the variation of the morphology. We also find that at long grafted chain length, the stress–strain behavior of the system with the semi-flexible grafted chain begins to exceed that of the system with the flexible grafted chain, attributed to the physical inter-locking interaction between the matrix and grafted polymer chains. A similar transition trend is as well found in the presence of the interfacial chemical couplings between grafted and matrix polymer chains. In general, this work is expected to help to design and fabricate high performance polymer nanocomposites filled with grafted NPs with excellent and controllable mechanical properties.

  8. Sodium and chloride exclusion and retention by non-grafted and grafted melon and Cucurbita plants

    Science.gov (United States)

    Edelstein, M.; Plaut, Z.; Ben-Hur, M.

    2011-01-01

    The effects of grafting on Na and Cl– uptake and distribution in plant tissues were quantified in a greenhouse experiment using six combinations of melon (Cucumis melo L. cv. Arava) and pumpkin (Cucurbita maxima Duchesne×Cucurbita moschata Duchesne cv. TZ-148): non-grafted, self-grafted, melons grafted on pumpkins, and pumpkins grafted on melons. Total Na concentration in shoots of plants with pumpkin or melon rootstocks was 400 mmol kg−1, respectively, regardless of the scion. In contrast, shoot Cl– concentrations were quite similar among the different scion–rootstock combinations. Na concentrations in exudates from cut stems of plants with a pumpkin rootstock were very low (<0.18 mM), whereas those in the exudates of plants with melon rootstocks ranged from 4.7 mM to 6.2 mM, and were quite similar to the Na concentration in the irrigation water. Root Na concentrations averaged 11.7 times those in the shoots of plants with pumpkin rootstocks, while in plants with melon rootstocks, values were similar. Two mechanisms could explain the decrease in shoot Na concentrations in plants with pumpkin rootstocks: (i) Na exclusion by the pumpkin roots; and (ii) Na retention and accumulation within the pumpkin rootstock. Quantitative analysis indicated that the pumpkin roots excluded ∼74% of available Na, while there was nearly no Na exclusion by melon roots. Na retention by the pumpkin rootstocks decreased its amount in the shoot by an average 46.9% compared with uniform Na distribution throughout the plant. In contrast, no retention of Na could be found in plants grafted on melons. PMID:20729482

  9. Sodium and chloride exclusion and retention by non-grafted and grafted melon and Cucurbita plants.

    Science.gov (United States)

    Edelstein, M; Plaut, Z; Ben-Hur, M

    2011-01-01

    The effects of grafting on Na and Cl(-) uptake and distribution in plant tissues were quantified in a greenhouse experiment using six combinations of melon (Cucumis melo L. cv. Arava) and pumpkin (Cucurbita maxima Duchesne×Cucurbita moschata Duchesne cv. TZ-148): non-grafted, self-grafted, melons grafted on pumpkins, and pumpkins grafted on melons. Total Na concentration in shoots of plants with pumpkin or melon rootstocks was 400 mmol kg(-1), respectively, regardless of the scion. In contrast, shoot Cl(-) concentrations were quite similar among the different scion-rootstock combinations. Na concentrations in exudates from cut stems of plants with a pumpkin rootstock were very low (<0.18 mM), whereas those in the exudates of plants with melon rootstocks ranged from 4.7 mM to 6.2 mM, and were quite similar to the Na concentration in the irrigation water. Root Na concentrations averaged 11.7 times those in the shoots of plants with pumpkin rootstocks, while in plants with melon rootstocks, values were similar. Two mechanisms could explain the decrease in shoot Na concentrations in plants with pumpkin rootstocks: (i) Na exclusion by the pumpkin roots; and (ii) Na retention and accumulation within the pumpkin rootstock. Quantitative analysis indicated that the pumpkin roots excluded ∼74% of available Na, while there was nearly no Na exclusion by melon roots. Na retention by the pumpkin rootstocks decreased its amount in the shoot by an average 46.9% compared with uniform Na distribution throughout the plant. In contrast, no retention of Na could be found in plants grafted on melons.

  10. Arterial grafts balance survival between incomplete and complete revascularization: a series of 1000 consecutive coronary artery bypass graft patients with 98% arterial grafts.

    Science.gov (United States)

    Kieser, Teresa M; Curran, Helen J; Rose, M Sarah; Norris, Colleen M; Graham, Michelle M

    2014-01-01

    Coronary artery bypass grafting (CABG) with incomplete revascularization (ICR) is thought to decrease survival. We studied the survival of patients with ICR undergoing total arterial grafting. In a consecutive series of all-comer 1000 patients with isolated CABG, operative and midterm survival were assessed for patients undergoing complete versus ICR, with odds ratios and hazard ratios, adjusted for European System for Cardiac Operative Risk Evaluation category, CABG urgency, age, and comorbidities. In this series of 1000 patients with 98% arterial grafts (2922 arterial, 59 vein grafts), 73% of patients with multivessel disease received bilateral internal mammary artery grafts. ICR occurred in 140 patients (14%). Operative mortality was 3.8% overall, 8.6% for patients with ICR, and 3.2% for patients with complete revascularization (P = .008). For operative mortality using multivariable logistic regression, after controlling for European System for Cardiac Operative Risk Evaluation category (P System for Cardiac Operative Risk Evaluation category (P reserved.

  11. Quantifying Long-term Retention of Excised Fat Grafts

    DEFF Research Database (Denmark)

    Herly, Mikkel; Ørholt, Mathias; Glovinski, Peter V.

    2017-01-01

    Background: Predicting the degree of fat graft retention is essential whenplanning reconstruction or augmentation with free fat grafting. Most surgeonsobserve volume loss over time after fat grafting; however, the portion lost toresorption after surgery is still poorly defined, and the time...... to reach steadystate is unknown. Methods: The authors compiled a retrospective, longitudinal cohort of patientswith vestibular schwannoma who had undergone ablative surgery and reconstructionwith excised fat between the years 2006 and 2015. Fat volume retentionwas quantified by computed tomography....... The average baseline graft volumewas 18.1 ± 4.8 ml. The average time to reach steady state was 806 days aftertransplantation. By this time, the average fat graft retention was 50.6 percent(95 percent CI, 46.4 to 54.7 percent). No statistically significant association wasfound between baseline graft volume...

  12. Melting and glass transition of radiation-induced graft polyethylene

    International Nuclear Information System (INIS)

    Toi, K.; Kikuchi, M.; Tokuda, T.

    1977-01-01

    Melting and glass transition data are reported employing DSC for styrene-grafted high-density polyethylene obtained by γ radiation. Judging from the data of the melting point and the heat of fusion, the grafted polystyrene had no effect on the polyethylene crystallites, but the half-width of the thermogram was observed to increase slightly, showing an effect on the crystallite size distribution. As no effect was observed on the glass transition temperature by grafting, the amorphous region of the polyethylene apparently was not affected. It is suggested, therefore, that the free volume or segmental mobility will not be decreased by radiation-induced grafting. Very few but long grafted chains had negligible effect on the average polyethylene chain length available for segmental motion, and grafted polystyrene should be expected to differ from the styrene homopolymer in thermal motions

  13. Striatal grafts in a rat model of Huntington's disease

    DEFF Research Database (Denmark)

    Guzman, R; Meyer, M; Lövblad, K O

    1999-01-01

    , which was found unaltered for the first 21 days posttransplantation, whereas a hypointense graft signal was detected at 99 days posttransplantation. At 2 days posttransplantation, T2-weighted images showed the graft region as a hyperintense area surrounded by a rim of low signal intensity but at later...... time-points graft location could not be further verified. Measures for graft size and ventricle size obtained from MR images highly correlated with measures obtained from histologically processed sections (R = 0.8, P ...Survival and integration into the host brain of grafted tissue are crucial factors in neurotransplantation approaches. The present study explored the feasibility of using a clinical MR scanner to study striatal graft development in a rat model of Huntington's disease. Rat fetal lateral ganglionic...

  14. Radiation grafting of styrene on starch with high efficiency

    Science.gov (United States)

    Sheikh, N.; Akhavan, A.; Ataeivarjovi, E.

    2013-04-01

    Wheat starch grafted with polystyrene (PS-g-starch) was synthesized via polymerization grafting of styrene on starch by gamma-ray. The effects of starch/styrene weight ratio, and amount of applied doses (5-40 kGy) on the percentage of grafting, G (%), were investigated. The results showed that G (%) increased with increasing starch content. The optimum condition, starch/styrene weight ratio 1/3 and the applied dose 10 kGy, led to 252.9% of grafting. The obtained graft copolymer was characterized by Fourier transform infrared spectroscopy, X-ray diffraction, thermal gravimetric analysis, and scanning electron microscopy. FTIR spectroscopy as well as the XRD analysis exhibited the changes in chemical and crystalline structure of starch after grafting reaction. TGA demonstrated the changes in thermal stability of PS-g-starch copolymer. SEM micrographs indicated porous patches of PS adhering on the starch.

  15. Chitosan-graft-branched polyethylenimine copolymers: influence of degree of grafting on transfection behavior.

    Directory of Open Access Journals (Sweden)

    Daniele Pezzoli

    Full Text Available BACKGROUND: Successful non-viral gene delivery currently requires compromises to achieve useful transfection levels while minimizing toxicity. Despite high molecular weight (MW branched polyethylenimine (bPEI is considered the gold standard polymeric transfectant, it suffers from high cytotoxicity. Inversely, its low MW counterpart is less toxic and effective in transfection. Moreover, chitosan is a highly biocompatible and biodegradable polymer but characterized by very low transfection efficiency. In this scenario, a straightforward approach widely exploited to develop effective transfectants relies on the synthesis of chitosan-graft-low MW bPEIs (Chi-g-bPEI(x but, despite the vast amount of work that has been done in developing promising polymeric assemblies, the possible influence of the degree of grafting on the overall behavior of copolymers for gene delivery has been largely overlooked. METHODOLOGY/PRINCIPAL FINDINGS: With the aim of providing a comprehensive evaluation of the pivotal role of the degree of grafting in modulating the overall transfection effectiveness of copolymeric vectors, we have synthesized seven Chi-g-bPEI(x derivatives with a variable amount of bPEI grafts (minimum: 0.6%; maximum: 8.8%. Along the Chi-g-bPEI(x series, the higher the degree of grafting, the greater the ζ-potential and the cytotoxicity of the resulting polyplexes. Most important, in all cell lines tested the intermediate degree of grafting of 2.7% conferred low cytotoxicity and higher transfection efficiency compared to other Chi-g-bPEI(x copolymers. We emphasize that, in transfection experiments carried out in primary articular chondrocytes, Chi-g-bPEI(2.7% was as effective as and less cytotoxic than the gold standard 25 kDa bPEI. CONCLUSIONS/SIGNIFICANCE: This work underlines for the first time the pivotal role of the degree of grafting in modulating the overall transfection effectiveness of Chi-g-bPEI(x copolymers. Crucially, we have demonstrated

  16. Chitosan-graft-branched polyethylenimine copolymers: influence of degree of grafting on transfection behavior.

    Science.gov (United States)

    Pezzoli, Daniele; Olimpieri, Francesca; Malloggi, Chiara; Bertini, Sabrina; Volonterio, Alessandro; Candiani, Gabriele

    2012-01-01

    Successful non-viral gene delivery currently requires compromises to achieve useful transfection levels while minimizing toxicity. Despite high molecular weight (MW) branched polyethylenimine (bPEI) is considered the gold standard polymeric transfectant, it suffers from high cytotoxicity. Inversely, its low MW counterpart is less toxic and effective in transfection. Moreover, chitosan is a highly biocompatible and biodegradable polymer but characterized by very low transfection efficiency. In this scenario, a straightforward approach widely exploited to develop effective transfectants relies on the synthesis of chitosan-graft-low MW bPEIs (Chi-g-bPEI(x)) but, despite the vast amount of work that has been done in developing promising polymeric assemblies, the possible influence of the degree of grafting on the overall behavior of copolymers for gene delivery has been largely overlooked. With the aim of providing a comprehensive evaluation of the pivotal role of the degree of grafting in modulating the overall transfection effectiveness of copolymeric vectors, we have synthesized seven Chi-g-bPEI(x) derivatives with a variable amount of bPEI grafts (minimum: 0.6%; maximum: 8.8%). Along the Chi-g-bPEI(x) series, the higher the degree of grafting, the greater the ζ-potential and the cytotoxicity of the resulting polyplexes. Most important, in all cell lines tested the intermediate degree of grafting of 2.7% conferred low cytotoxicity and higher transfection efficiency compared to other Chi-g-bPEI(x) copolymers. We emphasize that, in transfection experiments carried out in primary articular chondrocytes, Chi-g-bPEI(2.7%) was as effective as and less cytotoxic than the gold standard 25 kDa bPEI. This work underlines for the first time the pivotal role of the degree of grafting in modulating the overall transfection effectiveness of Chi-g-bPEI(x) copolymers. Crucially, we have demonstrated that, along the copolymer series, the fine tuning of the degree of grafting

  17. Clinically relevant mechanical testing of hernia graft constructs.

    Science.gov (United States)

    Sahoo, Sambit; DeLozier, Katherine R; Erdemir, Ahmet; Derwin, Kathleen A

    2015-01-01

    To understand the mechanical behavior of grafts in the context of hernia repair, there is a need to develop and adopt methods for mechanical testing of grafts in a clinically-relevant manner with clinically-relevant outcomes. Ball-burst and planar-biaxial methods were used to test three commercially-available hernia grafts (DermaMatrix, Biodesign, VitaMesh Blue). Both load-to-failure and cyclic fatigue tests were performed (n=6-11/group/test). Grafts were tested as sutured constructs in patch geometry. Dilatational strain analysis was performed considering the construct (both test methods) or the graft (planar-biaxial only) as the area of interest. DermaMatrix, Biodesign, and VitaMesh grafts showed differences in mechanical properties at the point of construct failure (load, in-plane load-per-suture and membrane tension) in ball-burst tests and differences in sub-failure properties (stiffness, dilatational strain at 16N/cm and cyclic mechanical properties) in planar-biaxial tests. In both load-to-failure and cyclic fatigue tests, each graft construct tended to be stiffer in planar-biaxial than ball-burst testing. In biaxial testing, the strain analysis method influenced the mechanical properties with the construct being more compliant than the graft. This study demonstrates that graft-fixation method, test mode and analysis method are important considerations for mechanical characterization of hernia grafts. Ball-burst tests can only estimate construct or material properties, whereas planar-biaxial tests capture anisotropy and can estimate construct, graft and material properties of the same test specimen. When the clinical performance of a graft in the context of hernia repair is of interest, testing a sutured construct and performing construct strain analysis arguably provides the most clinically-relevant assessment method. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. The effect of carbon dioxide therapy on composite graft survival

    OpenAIRE

    Durães, Eliana Ferreira Ribeiro; Durães, Leonardo de Castro; Carneiro, Fabiana Pirani; Lino Júnior, Ruy de Souza; Sousa, João Batista de

    2013-01-01

    PURPOSE: To investigate the effect of carboxytherapy in auricular composite grafts in rabbits. METHODS: An experimental study was conducted using 20 rabbits randomly assigned to a treatment group of carboxytherapy or a control group of saline solution. In each ear, a circular graft with 1.5 cm or 2 cm of diameter was amputated and reattached. Animals underwent carbon dioxide or saline injection four times during the experiment. We analyzed clinical evolution of the animals, grafts survival, h...

  19. Global DNA methylation changes in Cucurbitaceae inter-species grafting

    OpenAIRE

    Avramidou,Evangelia; Kapazoglou,Aliki; Aravanopoulos,Filippos A.; Xanthopoulou,Aliki; Ganopoulos,Ioannis; Tsaballa,Aphrodite; Madesis,Panagiotis; Doulis,Andreas G.; Tsaftaris,Athanasios

    2015-01-01

    Grafting has been used to improve yield, fruit quality and disease resistance in a range of tree and vegetable species. The molecular mechanisms underpinning grafting responses have only recently started to be delineated. One of those mechanisms involves long distance transfer of genetic material from rootstock to scion alluding to an epigenetic component to the grafting process. In the research presented herein we extended published work on heritable changes in the DNA methylation p...

  20. Target-like pigmentation after minipunch grafting in stable vitiligo

    Directory of Open Access Journals (Sweden)

    Nelee Bisen

    2014-01-01

    Full Text Available Surgical treatment for vitiligo has been ever evolving. Each surgical modality has its own benefits and limitations. Miniature punch grafting is the most extensively performed surgery, which gives good results in stable vitiligo. Herein we report an unusual type of repigmentation observed after minipunch grafting in a patient of stable vitiligo, which resembled target-like lesions with a "perigraft halo" surrounding individual grafts. Such pigment spread occurred despite the use of 0.5 mm larger graft from the donor site.

  1. Autogenous tooth bone graft: Ingenious bone regeneration material

    Directory of Open Access Journals (Sweden)

    Chadalavada Sarala

    2018-01-01

    Full Text Available Tooth-derived bone graft material, which is proved to be rich in bone growth factors and bone morphogenic proteins (BMPs, have been becoming a practical substitute to bone grafting. It can also be used as a carrier for growth factors and stem cells as reported in many recent studies. Autogenous-tooth bone grafting technique is significant as this biomaterial has excellent bone regeneration capacity and also relatively non-existent chances of antigenicity, genetic diseases and disease transmission. In this article, a broad overview of the published findings with regard to the properties and uses of tooth-derived regenerative bone grafting is discussed.

  2. A rapid, reproducible, noninvasive predictor of liver graft survival.

    Science.gov (United States)

    Zarrinpar, Ali; Lee, Coney; Noguchi, Emily; Yersiz, Hasan; Agopian, Vatche G; Kaldas, Fady M; Farmer, Douglas G; Busuttil, Ronald W

    2015-07-01

    Clinical and laboratory criteria are not reliable predictors of deceased donor liver graft quality. Intraoperative assessment of experienced surgeons is the gold standard. Standardizing and quantifying this assessment is especially needed now that regional sharing is the rule. We prospectively evaluated a novel, simple, rapid, noninvasive, quantitative measure of liver function performed before graft procurement. Using a portable, finger-probe-based device, indocyanine green plasma disappearance rates (ICG-PDR) were measured in adult brain-dead donors in the local donor service area before organ procurement. Results were compared with graft function and outcomes. Both donor and recipient teams were blinded to ICG-PDR measurements. Measurements were performed on 53 consecutive donors. Eleven liver grafts were declined by all centers because of quality; the other 42 grafts were transplanted. Logistic regression analysis showed ICG-PDR to be the only donor variable to be significantly associated with 7-d graft survival. Donor risk index, donor age, and transaminase levels at peak or procurement were not significantly associated with 7-d graft survival. We report the successful use of a portable quantitative means of measuring liver function and its association with graft survival. These data warrant further exploration in a variety of settings to evaluate acceptable values for donated liver grafts. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Incomplete Excluder limb graft deployment: cause and solution.

    Science.gov (United States)

    Klonaris, Chris; Katsargyris, Athanasios; Koutsoumpelis, Andreas; Kouvelos, George; Georgopoulos, Sotiris

    2014-01-01

    The Excluder stent graft (W.L. Gore and Associates, Flagstaff, AZ) is one of the most frequently used devices for endovascular abdominal aortic aneurysm repair and offers the advantage of a simple and reliable deployment mechanism. We report an unexpected complication during deployment of an Excluder limb graft; the "rip cord" deployment system broke during pulling, most probably because of interference with a previously placed common iliac artery stent, thereby resulting in incomplete graft deployment. This report notes that problems may rarely arise when deploying an Excluder limb graft within already stented iliac arteries and provides technical considerations to manage such events successfully. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Do Stem Cells Have an Effect When We Fat Graft?

    Science.gov (United States)

    Rinker, Brian D; Vyas, Krishna S

    2016-06-01

    Fat grafting has become a widely accepted modality of soft tissue restoration and has found applications in many areas of aesthetic and reconstructive plastic surgery. Numerous claims have been made regarding the regenerative effects of fat grafting on the recipient bed. The purpose of this paper is to survey the available literature to answer the question of whether fat grafting has a positive effect on the surrounding tissues. It has been convincingly demonstrated that fat grafts contain viable adipose-derived stem cells (ASCs). The fate of these cells is determined by the microenvironment of the recipient bed, but animal studies have shown that a large fraction of ASCs survive engraftment. Numerous clinical studies have demonstrated the positive effects of fat grafting on recipient tissues. Improvement in validated scar scores as well as scar stiffness measurements have been documented after fat grafting of burn scars. Fat grafting has also been convincingly demonstrated to improve the quality of irradiated tissues, as measured by validated clinical scales and staged histology. It is ultimately unclear whether ASCs are responsible for these effects, but the circumstantial evidence is weighty. Fat grafting is effective for volumizing and improving skin quality in the setting of radiation, burns, and other scars. The observed effects are likely due to ASCs, but the evidence does not support the routine use of ASC-enriched fat grafts.

  5. Crystallization of calcium carbonate on radiation-grafted polyethylene films

    International Nuclear Information System (INIS)

    Hou Zhengchi; Zhang Fengying; Deng Bo; Yang Haijun; Chen Shuang; Sheng Kanglong

    2006-01-01

    In biomineralization processes, nucleation and growth of inorganic crystals can be regulated by organic template molecules. This has inspired great interest in studying mimic biomineralization. In our study, growing CaCO 3 crystals on PE films functionalized through radiation-induced grafting was attempted. PE films grafted with different functional groups of different distributions and densities were used as substrates for CaCO 3 nucleation and crystal growth from Ca(HCO 3 ) 2 supersaturated solution under different environmental conditions (e.g. additives and temperature) to study the effects and mechanisms. The grafted PE films were analyzed by ATR-FTIR and AFM, and the evolution of CaCO 3 crystal formation on the grafted PE film was characterized by SEM, FTIR, and XRD. The results indicated that heterogeneous nucleation of CaCO 3 crystals was significantly facilitated by the functional groups grafted on the surface of PE films, that the morphology of CaCO 3 crystals could be controlled by distribution and density of the grafted functional groups, and that polymorphism of CaCO 3 crystal could be regulated by selection of grafting functional groups. We believe that studying the effects of chemical structures on inorganic crystallization is of great importance since radiation-induced grafting is an effective method to graft desirable functional groups onto different polymers by selected monomers, in the endeavor of developing advanced organic/inorganic composites with high performance, with a wide availability of polymers, monomers and inorganic solutions. (authors)

  6. A Novel Porcine Graft for Regeneration of Bone Defects

    Directory of Open Access Journals (Sweden)

    Eisner Salamanca

    2015-05-01

    Full Text Available Bone regeneration procedures require alternative graft biomaterials to those for autogenous bone. Therefore, we developed a novel porcine graft using particle sizes of 250–500 μm and 500–1000 μm in rabbit calvarial bone defects and compared the graft properties with those of commercial hydroxyapatite (HA/beta-tricalcium phosphate (β-TCP over eight weeks. Surgery was performed in 20 adult male New Zealand white rabbits. During a standardized surgical procedure, four calvarial critical-size defects of 5 mm diameter and 3 mm depth were prepared. The defects were filled with HA/β-TCP, 250–500 μm or 500–1000 μm porcine graft, and control defects were not filled. The animals were grouped for sacrifice at 1, 2, 4, and 8 weeks post-surgery. Subsequently, sample blocks were prepared for micro-computed tomography (micro-CT scanning and histological sectioning. Similar bone formations were observed in all three treatment groups, although the 250–500 μm porcine graft performed slightly better. Rabbit calvarial bone tissue positively responded to porcine grafts and commercial HA/β-TCP, structural analyses showed similar crystallinity and porosity of the porcine and HA/β-TCP grafts, which facilitated bone formation through osteoconduction. These porcine grafts can be considered as graft substitutes, although further development is required for clinical applications.

  7. MRI of double-bundle ACL reconstruction: evaluation of graft findings

    Energy Technology Data Exchange (ETDEWEB)

    Kiekara, Tommi; Paakkala, Antti [Tampere University Hospital, Medical Imaging Centre, Tampere (Finland); Jaervelae, Timo [Sports Clinic and Hospital Mehilaeinen, Tampere (Finland); Huhtala, Heini [University of Tampere, School of Health Sciences, Tampere (Finland)

    2012-07-15

    To demonstrate the magnetic resonance imaging (MRI) findings of double-bundle (DB) anterior cruciate ligament (ACL) reconstruction grafts. Sixty-six patients with DB ACL reconstruction were evaluated with MRI 2 years postoperatively. Graft thickness was measured separately by two musculoskeletal radiologists. The MRI findings of graft disruption, signal intensity (SI) changes, cystic degeneration, arthrofibrosis, and impingement were analyzed. The statistical significance of the association between MRI findings was calculated. The mean anteromedial (AM) graft thickness was reduced 9% and the mean posterolateral (PL) graft thickness was reduced 18% from the original graft thickness. Disruption was seen in 3% of AM grafts and 6% of PL grafts and a partial tear in 8 and 23%, respectively. Both grafts were disrupted in 3% of patients. Increased SI was seen in 14% of intact AM grafts and in 60% of partially torn AM grafts (p = 0.032). In PL grafts the increased SI was seen in 51% of the intact grafts and in 93% of the partially torn grafts (p = 0.005). Cystic degeneration was seen in 8% of AM grafts and in 5% of PL grafts. Diffuse arthrofibrosis was seen in 5% of patients and a localized cyclops lesion in 3% of patients. Impingement of the AM graft was seen in 8% of patients. Both grafts were disrupted in 3% of patients. Also, the frequencies of other complications were low. The use of orthogonal sequences in the evaluation of the PL graft SI seems to cause volume-averaging artefacts. (orig.)

  8. Perfluorinated polymer grafting: influence of preirradiation conditions

    International Nuclear Information System (INIS)

    Moura, E.; Somessari, E.S.R.; Silveira, C.G.; Paes, H.A.; Sousa, C.A.; Fernandes, W.; Manzoli, J.E; Geraldo, A.B.; Cardozo, P.

    2009-01-01

    The technological interest of perfluorinated polymers is related to its specific properties like low chemical reactivity and high mechanical and temperature resistance. The development of polymeric membranes for PEM fuel cell dispositives requires beyond these characteristics, a long-life time performance and low cost compared to Nafion membranes. By these material have high crystallinity, the radiation grafting indeed occurs but this process generate a low mechanical resistance aggregate. In this way, it is necessary to render the polymer with a low crystallinity or even amorphous. Generally, irradiation under polymer melt temperatures makes the crystallinity breaking and polymer crosslinking. The main objective of this work was promoting the crosslinking process into perfluorinated polymers by pre-irradiation method and to precede styrene grafting by electron beam irradiation in a second step. The experimental methodology consists in pre-irradiate perfluorinated polymers films like PTFE and PFA under high temperature (> 300 deg C) and vacuum conditions by electron beam irradiation at 5 kGy to 30 kGy doses and 2,85 kGy/s to 22,4 kGy/s dose rates. To obtain temperatures above 300 deg C, it was necessary construct a vacuum chamber with a heating system where temperature process could be follow up in real time. Some molecular alterations in polymeric matrix were analyzed by Mid-ATR-FTIR spectroscopy; macroscopic changes are verified by gravimetry. The styrene grafting onto these samples is realized by electron beam irradiation at doses between 30 and 100 kGy. These results are discussed. (author)

  9. Intraoperative echocardiographic imaging of coronary arteries and graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass.

    Science.gov (United States)

    Suematsu, Y; Takamoto, S; Ohtsuka, T

    2001-12-01

    No accepted approach exists for the intraoperative evaluation of the quality of coronary arteries and the technical adequacy of graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass. We assessed the accuracy of high-frequency epicardial echocardiography and power Doppler imaging in evaluating coronary arteries during coronary artery bypass grafting without cardiopulmonary bypass. To validate measurements of coronary arteries and graft anastomoses by high-frequency epicardial echocardiography and power Doppler imaging, we compared luminal diameters determined by these methods with diameters determined histologically in a study of off-pump coronary artery bypass grafting in 20 dogs. Technical errors were deliberately created in 10 grafts (stenosis group). The results of these animal validation studies showed that the maximum luminal diameters of coronary arteries and graft anastomoses measured by high-frequency epicardial echocardiography (HEE) and power Doppler imaging (PDI) correlated well with the histologic measurements: HEE = 1.027 x Histologic measurements + 0.005 (P anastomoses were examined intraoperatively by high-frequency epicardial echocardiography and power Doppler imaging, and luminal diameters determined by power Doppler imaging were compared with those determined by postoperative coronary angiography. The results demonstrated that graft anastomosis by power Doppler imaging correlated well with the angiographic measurements: PDI = 1.018 x Angiographic measurements - 0.106 (P anastomoses and can detect technical errors and inadequacies during coronary artery bypass grafting without cardiopulmonary bypass.

  10. Improved patency and reduced intimal hyperplasia in PTFE grafts with luminal immobilized heparin compared with standard PTFE grafts at six months in a sheep model.

    Science.gov (United States)

    Pedersen, G; Laxdal, E; Ellensen, V; Jonung, T; Mattsson, E

    2010-06-01

    The aim of this study was to compare the performance of polytetrafluoroethylene (PTFE) grafts with luminal coating of immobilized heparin to that of standard PTFE grafts at six months. Twenty-eight common carotid arteries in fourteen sheep were bypassed with heparin-coated PTFE grafts (6 mm diameter, 6 cm length) on one side and standard PTFE grafts on the other. The grafts were explanted after six months. The thickness of intimal hyperplasia (IH) in open grafts was measured with histomorphometrical methods. Two of 14 heparinized PTFE grafts and nine of 14 grafts in the control PTFE-group were occluded at explantation (P=0.006). Six-month patency rates for heparinized PTFE grafts and for standard PTFE grafts were 86% and 36%, respectively. Mean graft anastomotic IH thickness in open grafts were 0.074 mm for heparinized PTFE grafts and 0.259 mm for PTFE-grafts (P=0.006). PTFE grafts with luminal coating containing immobilized heparin had significantly better patency and recruited less intimal hyperplasia than standard PTFE grafts at six months.

  11. Bone scintigraphy in evaluating the viability of composite bone grafts revascularized by microvascular anastomoses, conventional autogenous bone grafts, and free non-revascularized periosteal grafts

    International Nuclear Information System (INIS)

    Berggren, A.; Weiland, A.J.; Ostrup, L.T.

    1982-01-01

    Researchers studied the value of bone scintigraphy in the assessment of anastomotic patency and bone-cell viability in free bone grafts revascularized by microvascular anastomoses in twenty-seven dogs. The dogs were divided into three different groups, and scintigraphy was carried out using technetium-labeled methylene diphosphonate in composite bone grafts revascularized by microvascular anastomoses, conventional autogenous bone grafts, and periosteal grafts placed in different recipient beds. The viability of the grafts were evaluated by histological examination and fluorescence microscopy after triple labeling with oxytetracycline on the first postoperative day, alizarin complexone on the fourth postoperative day, and DCAF on the eleventh postoperative day. A positive scintiscan within the first week following surgery indicated patent microvascular anastomoses, and histological study and fluorescence microscopy confirmed that bone throughout the graft was viable. A positive scintiscan one week after surgery or later does not necessarily indicate microvascular patency or bone-cell survival, because new bone formed by creeping substitution on the surface of a dead bone graft can result in this finding

  12. [Effect of T-cell depletion of the graft on graft survival and graft vs host disease].

    Science.gov (United States)

    Irlé, C; Aapro, M; Chapuis, B; Kaestli, M; Marin, P; Jeannet, M

    1986-11-29

    A limiting dilution culture method has been developed which allows the detection of small numbers of residual marrow T cells following their depletion with the monoclonal antibody Campath-I and autologous complement. In seven consecutive patients the degree of T cell depletion obtained was 1.82 (1.27-2.82) log. The number of nucleated cells per kg decreased by 50% and the number of CFU-GM per kg decreased by 60%. In all except one case marrow cellularity was found to be satisfactory 3 weeks after the transplant. Peripheral engraftment of granulocytes (greater than 500/mm3 on day 20, greater than 1000/mm3 on day 27), lymphocytes (greater than 500 on day 39, greater than 1000 on day 66), platelets (greater than 20,000 and self-sustained after day 24) and red blood cells (day to last infusion = 19) indicated a delay in recovery of lymphocytes and possibly granulocytes, but not platelets or red blood cells, compared to the engraftment seen in non-T depleted patients. No correlation between nucleated cells infused, GFU-GM and engraftment was found. However, the extent of T cell depletion apparently affects lymphocyte, and possibly granulocyte, recovery. The delay in lymphoid engraftment is also reflected by nonresponsiveness to alloantigens during the first 6-9 months following marrow grafting in the absence of graft vs. host disease.

  13. Autologous Fat Grafting Combined with Facelifting.

    Science.gov (United States)

    Tzikas, Thomas

    2017-06-01

    There are multiple factors contributing to facial aging. Rejuvenation of the aging face, therefore, requires a multimodal approach to attain an overall natural and uniform result that is long lasting. Fat grafting has become a very important method for restoring facial soft-tissue atrophy, while facelifting procedures address the ptosis and descent of facial and neck tissue. These modalities performed together offer the patient a comprehensive approach to attain a more attractive and youthful facial appearance. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. Grafting of Porous Polymers for Biological Applications

    International Nuclear Information System (INIS)

    Smolko, E.E.; Grasselli, M.

    2009-01-01

    Research on application of radiation processing to polymers is mainly focused by the National Atomic Commission (CNEA). The Agricultural and Industrial Applications Laboratory Unit operates at the Ezeiza Atomic Center since the end of 1980s. Since 1997 a new research group headed by Dr. O. Cascone and Dr. M. Grasselli, devoted to downstream processing of proteins from the University of Buenos Aires, was involved in the implementation of grafting techniques in collaboration with Dr. E. Smolko from CNEA. In 1999 Dr. M. Grasselli moved to the Universidad Nacional de Quilmes where he continued working on application of gamma radiation to materials for biotechnological process. (author)

  15. [Immunological mechanisms of graft versus tumor effect].

    Science.gov (United States)

    Ine, Shoji; Yamada, Minami; Miyamura, Koichi; Sasaki, Takeshi

    2003-09-01

    Lesson from hematopoietic stem cell transplantation demonstrated that donor immuno-surveillance system can eradicate tumor cells. This is so-call graft versus tumor(GVT) effect. Antigen presenting cells show peptide from minor antigen rather leukemic specific antigen in the context of major histocompatibility complex. The effector cells composed of CD8 T lymphocyte, CD4 T lymphocyte, natural killer cell and natural killer T cell. Death signal was transmitted from effector cells via granzyme/perforin system and FasL/Fas system, and recently TRAIL system seems most important for GVT effect.

  16. Osseous scintigraphy and auxiliary graft. Scintigraphie osseuse et greffe d'appoint

    Energy Technology Data Exchange (ETDEWEB)

    Khelifa, F.; Siles, S. (Hopital de la Timone, 13 - Marseille (France)); Puech, B.

    1992-12-01

    The scintigraphy could be a good way to survey the osseous graft: three cases are studied in which were recognized the presence of a graft, surinfection, graft lysis, pseudo-arthrosis, algodystrophy. 8 refs., 5 figs.

  17. Characteristics of elongated and ruptured anterior cruciate ligament grafts: An analysis of 21 consecutive revision cases

    Directory of Open Access Journals (Sweden)

    Kohei Iio

    2017-04-01

    Conclusion: The location of the original femoral tunnel was more proximal in patients with elongated grafts than in those with ruptured grafts. Different bone tunnel position from native ACL might lead to graft elongation.

  18. Volume changes of grafted autogenous bone in sinus augmentation procedure.

    Science.gov (United States)

    Sbordone, Carolina; Sbordone, Ludovico; Toti, Paolo; Martuscelli, Ranieri; Califano, Luigi; Guidetti, Franco

    2011-06-01

    To evaluate associations between the osseous remodeling and the 3-dimensional features of both the grafted bone and the recipient site, as well as the density of the grafted bone, and to assess the relation between the degree of bone resorption and the type of autogenous bone-grafting procedure or the source (block or particulate bone from iliac crest or block bone from chin). A retrospective chart review of patients receiving sinus lifting and grafting procedures for implant positioning was conducted: radiographic analysis of the volume and area of both sinuses and autogenous bone grafts was performed, as per Smolka et al and Krennmair et al. The volumetric remodeling--measured at 1 year after implant positioning as the percentage of residual bone (%R)--was correlated, with Spearman analysis, to 3-dimensional features of both graft and recipient sites. All quantities correlated with %R at a statistically significant level were used for 2-dimensional and multidimensional visualizations with scattergrams. Twenty-five iliac crest or chin grafts were inlay positioned in the maxillary sinuses of patients. Computed tomography scans, taken before implant positioning and after 1 year, showed a 1-year negligible volume remodeling for block graft from chin (97.9%) but slightly greater resorption values (%R) for particulate and block grafts from iliac crest (93.8% and 83.3%, respectively). Three- and four-dimensional scattergrams of significant data resulting from Spearman correlation tests (particulate and block grafts both from iliac crest) showed a variation of the remodeling pattern dependent on 3-dimensional features, namely inlay graft thickness, surface area of the graft in contact with basal bone, volume of the recipient site, and surface area of the graft projecting into the sinus cavity. Retrospective data analysis shows that iliac crest grafts positioned on a small basal bone volume (≤ 2.5 mL) may point to a very favorable remodeling of the volume when the

  19. Electrospun vascular grafts with anti-kinking properties

    Directory of Open Access Journals (Sweden)

    Bode M.

    2015-09-01

    Full Text Available One of the major challenges in developing appropriate vascular substitutes is to produce a graft that adapts to the biological and mechanical conditions at the application or implantation site. One approach is the use of tissue engineered electrospun grafts pre-seeded with autologous cells. However, bending stresses during in vivo applications could lead to kinking of the graft which may result in life-threatening stenosis. The aim of this study was to develop an electrospun vascular graft consisting of biodegradable polymers which can reduce or prevent kinking, due to their higher flexibility. In order to improve the bendability of the grafts, various electrospinning collectors were designed using six different patterns. Subsequently, the grafts were examined for scaffold morphology, mechanical strength and bendability. Scaffolds spun on a collector structured with a v-shaped thread (flank angle of 120° showed a homogenous and reproducible fiber deposition as compared to the unstructured reference sample. The results of the tensile tests were comparable to the unstructured reference sample, supporting the first observation. Studies on bendability were performed using a custom made flow-bending test setup. It was shown that the flow through the v-shaped grafts was reduced to less than 45 % of the reference value even after bending the graft to an angle of 140°. In contrast, the flow through an unstructured graft was reduced to more than 50 % after bending to an angle of 55°. The presented data demonstrate the need for optimizing the bendability of the commonly used electrospun vascular grafts. Using of macroscopic v-shaped collectors is a promising solution to overcome the issue of graft kinking.

  20. Radiation-induced grafting of acrylamide onto guar gum in aqueous medium: Synthesis and characterization of grafted polymer guar-g-acrylamide

    Energy Technology Data Exchange (ETDEWEB)

    Biswal, Jayashree [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Kumar, Virendra [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Bhardwaj, Y.K. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India)]. E-mail: ykbhard@magnum.barc.ernet.in; Goel, N.K. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Dubey, K.A. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Chaudhari, C.V. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Sabharwal, S. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India)

    2007-10-15

    Mutual radiation grafting technique has been applied to carry out grafting of acrylamide (AAm) onto guar gum (GG) using high-energy Co{sup 60} {gamma} radiation to enhance its flocculating properties for industrial effluents. The grafted product was characterized using analytical probes like elemental analysis, thermal analysis, Fourier transformed infrared (FTIR), X-ray diffraction (XRD) and scanning electron microscope (SEM). The grafting extent was observed to decrease with the dose rate and increase with the concentration of AAm. Thermo gravimetric analysis (TGA) of grafted and ungrafted samples indicated better stability of grafted product. {gamma} and microwave radiation effect on grafted and virgin GG has also been reported.

  1. Effect of centrifugation and washing on adipose graft viability: a new method to improve graft efficiency.

    Science.gov (United States)

    Hoareau, Laurence; Bencharif, Karima; Girard, Anne-Claire; Gence, Lydie; Delarue, Pierre; Hulard, Olivier; Festy, Franck; Roche, Regis

    2013-05-01

    Adipose tissue grafting is a promising method in the field of surgical filling. We studied the effect of centrifugation on fat grafts, and we propose an optimised protocol for the improvement of adipose tissue viability. Adipose tissue was subjected to different centrifugations, and the volumes of interstitial liquid and oil released were measured to choose the optimal condition. Tissue from this condition was then compared to tissue obtained from two traditional techniques: strong centrifugation (commonly 3 min at 3000 rpm/900 g), and decantation, by injecting into immunodeficient mice. The cytokine interleukin-6 (IL-6) and chemokine monocyte chemotactic protein-1 (MCP-1) were assayed 24 h post-injection, and after 1 month of grafting the state of the lipografts was evaluated through macroscopic and histological analysis, with oil gap area measurement. Strong centrifugation (900 g, 1800 g) is deleterious for adipose tissue because it leads to until threefold more adipocyte death compared to low centrifugation (100 g, 400 g). In addition, mice injected with strong centrifuged and non-centrifuged adipose tissue have higher rates of blood IL-6 and MCP-1, compared to those grafted with soft centrifuged fat. Moreover, extensive lipid vacuoles were detectable on histological sections of the non-centrifuged lipografts, whereas lipografts from soft centrifugation contain a higher amount of connective tissue containing collagen fibres. It is necessary to wash and centrifuge adipose tissue before reinjection in order to remove infiltration liquid and associated toxic molecules, which in the long term are deleterious for the graft. However, strong centrifugation is not recommended since it leads very quickly to greater adipocyte death. Thus, soft centrifugation (400 g/1 min), preceded by washings, seems to be the most appropriate protocol for the reinjection of adipose tissue. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published

  2. Editorial Commentary: Size Does Matter-Anterior Cruciate Ligament Graft Diameter Affects Biomechanical and Clinical Outcomes.

    Science.gov (United States)

    Steiner, Mark

    2017-05-01

    Anterior cruciate ligament (ACL) graft strength is related to graft diameter and how ACL grafts heal. All grafts appear to lose strength during healing. Clinical studies have documented that hamstring grafts less than 8 mm wide are more vulnerable to failure. Tripling the semitendinosus allows to increase the graft diameter and strength. A recent study documents a semitendinosus tripling technique with excellent clinical results. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  3. Treatment of equine leg wounds using skin grafts: Thirty-five cases, 1975-1988

    OpenAIRE

    French, Daniel A.; Fretz, Peter B.

    1990-01-01

    A retrospective study was conducted on 35 equine patients with lower leg wounds that were managed utilizing skin graft procedures. Two pinch graft, five punch graft, seven tunnel graft, eight split-thickness mesh graft and thirteen full-thickness mesh expansion graft procedures were performed in the initial treatment. The average wound size was 188 cm2. Twentyfour cases had pregrafting complications: 10 wounds developed sequestra; three wounds were grossly contaminated and infected; and 11 ca...

  4. Outcomes of coronary artery bypass graft surgery

    Directory of Open Access Journals (Sweden)

    Anna Louise Hawkes

    2006-12-01

    Full Text Available Anna Louise Hawkes1,3, Madeleine Nowak1, Benjamin Bidstrup2, Richard Speare11School of Public Health, Tropical, Medicine and Rehabilitation Sciences, James Cook University, Townsville, Queensland, Australia (3Currently Queensland Cancer Fund; 2John Flynn Hospital, Gold Coast, Queensland, AustraliaAbstract: This review article summarizes the major studies that have investigated the outcomes of coronary artery bypass graft surgery (CABG. The article includes a review of the literature in the areas of: history of CABG; indications for CABG; and measurement of quality of life following CABG, including prolongation of life, physical functioning (ie, relief from angina and dyspnea, physical activity, as well as complications of surgery and re-hospitalization, psychological functioning, and social functioning. Overall, the literature demonstrates that the outcomes of CABG have historically been measured in terms of mortality and morbidity; however, it has now been well recognized that adjustment to CABG is a multidimensional phenomenon that is not fully explained by medical factors. Therefore, in addition to studying mortality and morbidity outcomes following CABG, many recent studies have identified that it is important to investigate various physical, psychological, and social variables that have a significant impact on post-operative adjustment to CABG. Keywords: coronary artery bypass graft surgery, outcomes, quality of life, recovery

  5. Effect of grafted oligopeptides on friction.

    Science.gov (United States)

    Iarikov, Dmitri D; Ducker, William A

    2013-05-14

    Frictional and normal forces in aqueous solution at 25 °C were measured between a glass particle and oligopeptide films grafted from a glass plate. Homopeptide molecules consisting of 11 monomers of either glutamine, leucine, glutamic acid, lysine, or phenylalanine and one heteropolymer were each "grafted from" an oxidized silicon wafer using microwave-assisted solid-phase peptide synthesis. The peptide films were characterized using X-ray photoelectron spectroscopy and secondary ion mass spectrometry. Frictional force measurements showed that the oligopeptides increased the magnitude of friction compared to that on a bare hydrophilic silicon wafer but that the friction was a strong function of the nature of the monomer unit. Overall we find that the friction is lower for more hydrophilic films. For example, the most hydrophobic monomer, leucine, exhibited the highest friction whereas the hydrophilic monomer, polyglutamic acid, exhibited the lowest friction at zero load. When the two surfaces had opposite charges, there was a strong attraction, adhesion, and high friction between the surfaces. Friction for all polymers was lower in phosphate-buffered saline than in pure water, which was attributed to lubrication via hydrated salt ions.

  6. Pediatric burn wound impetigo after grafting.

    Science.gov (United States)

    Aikins, Kimberly; Prasad, Narayan; Menon, Seema; Harvey, John G; Holland, Andrew J A

    2015-01-01

    Modern burn care techniques have reduced the risk of infection of the acute burn wound, resulting in more rapid healing and a lower incidence of graft loss. Secondary breakdown may still occur. The loss of epithelium in association with multifocal superficial abscesses and ulceration has been termed burns impetigo. This may result in considerable morbidity and require prolonged treatment. The events preceding development, the impact on the patient, and the ideal treatment appear unclear and poorly reported. In 5 years, between 2006 and 2011, 406 pediatric burns were treated with skin grafts, with 7% developing burns impetigo. Time to resolution ranged from 5 to 241 days: the mean time to complete healing was greatest with conservative management (96 days), followed by antibacterial dressings (37 days), oral antibiotics (36 days), topical steroids (16 days), and oral antibiotics in combination with topical steroids (13.5 days). Burns impetigo resulted in significant morbidity, requiring multiple visits to the treatment center and prolonged symptoms. Delay in diagnosis and treatment resulted in worse outcomes. Prompt consideration of burns impetigo should occur when postgraft patients present with suggestive clinical signs and treatment with oral antibiotics plus topical steroids should be considered.

  7. Studies of host graft interactions in vitro

    Science.gov (United States)

    Liljekvist-Larsson, Ingela; Johansson, Kjell

    2007-09-01

    Progenitor and stem cell transplantation represent therapeutic strategies for retinal disorders that are accompanied by photoreceptor degeneration. The transplanted cells may either replace degenerating photoreceptors or secrete beneficial factors that halt the processes of photoreceptor degeneration. The present study analyzes whether rat retinal progenitor cells differentiated into photoreceptor phenotypic cells in neurospheres have a potential to interact with rat retinal explants. Immunocytochemistry for rhodopsin and synaptophysin indicated photoreceptor cell-like differentiation in neurospheres that were stimulated by basic fibroblast growth factor and epidermal growth factor. Differentiation into neural phenotypes including photoreceptor cells was effectively blocked by an addition of leukemia inhibitory factor. Grafting of neurospheres onto retinal explants demonstrated a consistent penetration of glial cell processes into the explanted tissue. On the other hand, the incorporation of donor cells into explants was very low. A general finding was that neurospheres grafting was associated with local decrease in Müller cell activation in the explants. Further characterization of these effect(s) could provide further insight into progenitor cell-based therapies of retinal degenerative disorders.

  8. Tough and Sustainable Graft Block Copolymer Thermoplastics

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jiuyang; Li, Tuoqi; Mannion, Alexander M.; Schneiderman, Deborah K.; Hillmyer, Marc A.; Bates, Frank S. (UMM)

    2016-03-15

    Fully sustainable poly[HPMC-g-(PMVL-b-PLLA)] graft block copolymer thermoplastics were prepared from hydroxypropyl methylcellulose (HPMC), β-methyl-δ-valerolactone (MVL), and l-lactide (LLA) using a facile two-step sequential addition approach. In these materials, rubbery PMVL functions as a bridge between the semirigid HPMC backbone and the hard PLLA end blocks. This specific arrangement facilitates PLLA crystallization, which induces microphase separation and physical cross-linking. By changing the backbone molar mass or side chain composition, these thermoplastic materials can be easily tailored to access either plastic or elastomeric behavior. Moreover, the graft block architecture can be utilized to overcome the processing limitations inherent to linear block polymers. Good control over molar mass and composition enables the deliberate design of HPMC-g-(PMVL-b-PLLA) samples that are incapable of microphase separation in the melt state. These materials are characterized by relatively low zero shear viscosities in the melt state, an indication of easy processability. The simple and scalable synthetic procedure, use of inexpensive and renewable precursors, and exceptional rheological and mechanical properties make HPMC-g-(PMVL-b-PLLA) polymers attractive for a broad range of applications.

  9. Technical factors affecting cup stability in bone impaction grafting.

    NARCIS (Netherlands)

    Bolder, S.B.T.; Verdonschot, N.J.J.; Schreurs, B.W.

    2007-01-01

    Favourable long-term clinical results can be achieved by the bone impaction technique in bone stock deficient acetabuli. Originally, firm impaction of manually prepared bone grafts using a rongeur was performed. An alternative technique for producing bone grafts is reaming from the pelvic wall or

  10. Resorbable screws for fixation of autologous bone grafts

    NARCIS (Netherlands)

    Raghoebar, GM; Liem, RSB; Bos, RRM; van der Wal, JE; Vissink, A

    The aim of this study was to evaluate the suitability of resorbable screws made of poly (D,L-lactide) acid (PDLLA) for fixation of autologous bone grafts related to graft regeneration and osseointegration of dental implants. In eight edentulous patients suffering from insufficient retention of their

  11. The use of skin grafts in the management of dehorning ...

    African Journals Online (AJOL)

    ... associated with double surgery in autogenous-skin grafting and the anaesthetic risks of the patients. Disbudding at early stage of life in bucks prone to in-growing horns is recommended to animal owners as a management practice to avoid horn overgrowth at older stage. Keywords: Skin Grafts; Dehorning; Complications; ...

  12. Solvent influence during radiation induced grafting of styrene in PVDF

    International Nuclear Information System (INIS)

    Ferreira, Henrique P.; Parra, Duclerc F.; Lugao, Ademar B.

    2013-01-01

    Radiation-induced grafting was studied to produce styrene grafted poly(vinylidene fluoride) (PVDF) membranes. PVDF films with 0.125 mm thickness were irradiated at doses between 5 and 20 kGy in the presence of styrene/N,N-dimethylformamide (DMF), styrene/acetone or styrene/toluene solutions (1:1, v/v) at dose rate of 5 kGy h -1 by simultaneous method, using gamma rays from a Co-60, under nitrogen atmosphere and at room temperature. The films were characterized before and after modification by grafting yield (GY %), infrared spectroscopy (FT-IR), scanning electron microscopy (SEM and EDS), differential scanning calorimetry (DSC) and thermogravimetry (TG/DTG). GY results shows that grafting increases with dose and toluene hinders the grafting, leading to a small GY comparing to DMF and acetone. It was possible to confirm the grafting of styrene by FT-IR due to the new characteristics peaks and by the TG and DSC due to changes in thermal behavior of the grafted material. SEM and EDS show surface and cross-section distribution of the grafting, which takes place on the surface and heterogeneously with toluene as solvent and homogeneously and penetrating into the inner layers of the matrix using DMF and acetone as solvent. (author)

  13. Rootstock growth and development for increased graft success of ...

    African Journals Online (AJOL)

    STORAGESEVER

    2010-03-01

    Mar 1, 2010 ... Apart from the skills of grafters, the effects of different rootstock sizes on graft success remain unclear. According to Hartmann et al. (1997), 10 mm thick (dia- meter) is an ideal rootstock size for grafting fruit trees. However, this could depend on the species. For U. kirkiana, it is often hard to find scions that ...

  14. Characterization of Functionalized Acrylic acid /4- Vinyl Pyridine Graft Copolymers

    International Nuclear Information System (INIS)

    Kamal, H.; Mahmoud, Gh.A.; Hegazy, D.E.

    2009-01-01

    Properties and characterization of the membranes prepared by radiation grafting of acrylic acid (AAc) or/ and 4-vinyl pyridine (4VP) onto low density polyethylene (LDPE) and polypropylene (PP) films were carried out. The FTIR spectra for the grafted membranes were studied to evaluate the structure change as a result of grafting. The swelling behaviour of the graft copolymer in methanol was studied. It was found that the grafting of AAc and/ or 4- VP onto LDPE and PP resulted in introducing good hydrophilic properties to such polymer substrates. The hydrophilic properties were directly proportional to the amount of functional groups. The mechanical properties (Young's modulus, elongation percent and tensile strength) of the grafted membranes also, have been investigated. As the grafting degree increases, the modulus also increases. Increasing the hydrophilicity of the membranes by chemical treatment enhances its mechanical properties. The thermal parameters of the grafted membranes such as δH m1 . δH m2 , and T rc have been also studied by using DSC

  15. Radiation-induced grafting of vinyl fluoride to polyacrylonitrile fibers

    International Nuclear Information System (INIS)

    Asamov, M.K.; Ziyaev, A.L.; Yul'chibaev, A.A.; Usmanov, Kh.U.

    1981-01-01

    Experimental data on gamma-radiation grafting of vinyl fluoride to polyacrylonitrile fibers in the presence of some organic liquids are given. It is shown, that the presence of chloroform vapours in the system produce sensitizing effect. Grafting of vinyl fluoride to polyacrylonitrile fibers considerably increases their thermal stability, lengthening and decreases shrinkage [ru

  16. Functionalization of poly (4-vinylpyrrolidone) through γ - radiation induced grafting

    International Nuclear Information System (INIS)

    Pande, C.S.; Ambasta, A.K.; Kumari, Mamta; Sharma, Ajay

    2002-01-01

    Cross-linked poly(N-vinylpyrrolidone) and N-vinylimidazole were mutually irradiated in water under nitrogen with γ-radiations. A detailed study of grafting was made under various reaction parameters. The results have been compared with the grafting done in air. (author)

  17. Ga-67 citrate scan in vascular graft infection

    Energy Technology Data Exchange (ETDEWEB)

    Banzo, I.; Quirce, R.; Serrano, J.; Jimenez, J.; Tabuenca, O.; Carril, J.M. (Hospital Universitario Valdecilla, Santander (Spain))

    1992-11-01

    The clinical utility of the Ga-67 scan has been studied in 9 patients with clinical suspicion of vascular graft infection. Eleven grafts were analyzed: 4 aortobifemoral, 2 iliofemoral, 3 femoropopliteal, 1 axillofemoral, and 1 axillobifemoral. The Ga-67 scan was positive in 8 grafts with bacteriological proof of infection and negative in 3 grafts in which infection was ruled out by clinical follow-up. A Ga-67 scan also demonstrated the spread of infection to the thigh in two patients and to the pelvis in another two patients. In 4 patients CT was performed. The CT findings included graft thrombosis, perigraft fluid collection and thickened graft wall. No discrepancies were found between the CT scan and Ga-67 scan. In three patients a control Ga-67 scan was carried out after specific antibiotic and surgical treatment. Two of these showed increased Ga-67 uptake and spreading of infection along the graft; in the other patient, a Ga-67 scan revealed normalization after resolution of an abdominal abscess. In conclusion, the Ga-67 scan proved useful in the diagnosis of vascular graft infection, the definition of location of the extent of the disease and in the evaluation of the efficiency of treatment. (author).

  18. Pressure induced graft-co-polymerization of acrylonitrile onto ...

    Indian Academy of Sciences (India)

    WINTEC

    such as pressure, time, pH, concentrations of initiator and monomer were optimized to get maximum graft yield (35⋅59%). Grafted and ungrafted Saccharum cilliare fibres were then subjected to evaluation of some of their properties like swelling behaviour in different solvents, moisture absorbance under different humidity.

  19. 21 CFR 870.3450 - Vascular graft prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vascular graft prosthesis. 870.3450 Section 870... prosthesis. (a) Identification. A vascular graft prosthesis is an implanted device intended to repair... Prostheses 510(k) Submissions.” [66 FR 18542, Apr. 10, 2001] ...

  20. Preparation and characterization of a novel bone graft composite ...

    Indian Academy of Sciences (India)

    ... shown better mechanical properties. X-ray diffraction (XRD) data indicated the crystallographic nature of BA is akin to hydroxyapatite (HA) and both BA and ESP did not lose their crystalline nature when bone grafts were prepared. This revealed that ESP may be used as a component in bone graft utilizing the solid waste ...

  1. Minimizing Graft Preparation Failure in Descemet Membrane Endothelial Keratoplasty.

    Science.gov (United States)

    Livny, Eitan; Groeneveld-van Beek, Esther A; Lie, Jessica T; Mangundap, Kristin M; Bruinsma, Marieke; Birbal, Rénuka S; van der Wees, Jacqueline; Melles, Gerrit R J

    2017-12-01

    To report the failure rate of 2 graft preparation techniques for Descemet membrane endothelial keratoplasty (DMEK) and to evaluate how to minimize graft preparation failure. Retrospective, nonrandomized study at an eye bank specialized in graft preparation for lamellar keratoplasty. For 1416 donor corneas, the DMEK graft preparation failure rate was evaluated for 2 different techniques, technique I: "Standardized traditional technique" (n = 341) and technique II: "Standardized no-touch technique" (n = 933), and for grafts that were converted from technique II to technique I during preparation (n = 142). The overall failure rate averaged 3.9% (55/1416): 7.0% (24/341) for technique I and 2.9% (31/1075) for technique II (P preparations which were converted from technique II to technique I failed in 13.4% (19/142), whereas for grafts that were entirely prepared by technique II, the failure rate was only 1.3% (12/933). The endothelial cell density decrease (before compared with after preparation) did not differ for both techniques (1.1% vs. 0.2%, P > 0.05). Various DMEK graft preparation techniques may provide failure rates of preparation" approach (technique II) may combine good graft quality (completely intact endothelial cell layer, ie, negligible preparation-induced endothelial cell density decrease) with low risk of dissection failure, leaving the possibility of conversion to "traditional preparation" (technique I) as a backup method.

  2. Rootstock growth and development for increased graft success of ...

    African Journals Online (AJOL)

    . A study was carried out to evaluate the effects of rootstock diameter (at root collar), skills and experience of grafters on mango seedling thinning and grafting. Skilled and unskilled grafters were involved in grafting mango plants for at least ...

  3. Noradrenergic and cholinergic reinnervation of islet grafts in diabetic rats

    NARCIS (Netherlands)

    Houwing, H; VanAsperen, RM; VanderZee, EA; VanSuylichem, PTR; Oestreicher, AB; Steffens, AB; Strubbe, JH; Asperen, Roelie M. van

    1996-01-01

    Grafted islets become denervated due to the islet transplantation procedure. The aim of the present study was 1) to examine whether islet grafts in the liver, the spleen, and under the kidney capsule in rats become reinnervated following the transplantation and experimental procedures used in our

  4. Autologous Bone Grafts Use in Orthopaedic Practice in Abuja ...

    African Journals Online (AJOL)

    Background: There is widespread use of autologous bone grafts in orthopaedic practice in Nigeria but detailed indications, donor sites and complications following use have not been reported in different regions. Objective: This is to highlight the indications, sources and complications of autologous bone grafts use in Abuja, ...

  5. Sites of Autologous Bone Grafts in Orthopaedic Traumatology ...

    African Journals Online (AJOL)

    Background: The use of autologous bone graft in orthopaedic traumatology is not uncommon. But little work, from West African subregion, has been devoted to sites used as sources of autologous bone grafts. Objective: The purpose of this study was to evaluate the evolution of these different sampling sites of autologous ...

  6. Non-Vascularised Fibular Grafting After Resection of Distal Femoral ...

    African Journals Online (AJOL)

    Background: Vascularized fibular grafting, allografting, megaprosthesis and allograft-prosthesis composite are suitable limb salvage techniques after resection of ... the initial observation showed such a wide non-vascularized fibular grafting for arthrodesis of the knee after resection of the distal femoral tumours is a feasible ...

  7. Application of grafted polynomial function in forecasting cotton ...

    African Journals Online (AJOL)

    A study was conducted to forecast cotton production trend with the application of a grafted polynomial function in Nigeria from 1985 through 2013. Grafted models are used in econometrics to embark on economic analysis involving time series. In economic time series, the paucity of data and their availability has always ...

  8. Confined relaxations of grafted polymer in solutions of linear polymer

    Science.gov (United States)

    Poling-Skutvik, Ryan; Krishnamoorti, Ramanan; Conrad, Jacinta

    Using neutron spin echo spectroscopy (NSE), we investigate the relaxations of polymer grafted to silica nanoparticles dispersed in semidilute solutions of linear polymer. The grafted polymer has a radius of gyration comparable to radius of the silica nanoparticle with a moderate grafting density so that the grafted polymer is more extended than a Gaussian chain. On length scales ranging from 1 to 20 nm and time scales less than 100 ns, the dynamics of the grafted polymer deviate from the standard Zimm model derived for linear polymers. Instead, the polymer chains are confined and unable to fully relax over the experimental time. The confinement length agrees with the distance between chains decreases as the linear polymer concentration is increased. Additionally, the confinement length is independent of linear polymer molecular weight, suggesting that linear polymer cannot penetrate the grafted layer. Instead, the grafted chains collapse onto themselves, similar to the structural changes observed in systems of star and linear polymers at high concentrations of linear polymer. We verify this physical picture using small-angle x-ray scattering and atomic force microscopy to observe aggregation of grafted particles at high concentrations of linear polymer.

  9. The Graft Copolymerisation of Acrylamide onto Cellulose using ...

    African Journals Online (AJOL)

    DR. MIKE HORSFALL

    ABSTRACT: Graft copolymers of acrylamide onto holocellulose derived from cocoa. (Theobroma cacao) wood meal have been produced using hydroquinone enhanced Fe2+/H2O2 redox system. The addition of hydroquinone to the redox system affected the effectiveness of the redox system to initiate graft copolymer ...

  10. [Surgical management of limb prosthetic vascular graft exposure].

    Science.gov (United States)

    Wu, Hao; Wu, Wei-wei; Bai, Ming; Zeng, Rong; Song, Xiao-jun; Chen, Yu; Liu, Chang-wei

    2012-12-01

    To investigate the risk factors and surgical management of limb prosthetic vascular graft exposure. The clinical data of 17 patients suffering from limb prosthetic vascular graft exposure in Peking Union Medical College Hospital from August 2006 to December 2011 were retrospectively analyzed. Among 17 cases, 5 suffered from prosthetic vascular graft exposure after vascular bypass for the lower limb ischemia, whereas 12 were affected after the artificial graft arteriovenous fistula construction in the upper limbs for hemodialysis. The surgical procedures mainly included the local debridement as well as the local flap and transferred muscle-cutaneous flap reconstruction to preserve the prosthetic vascular graft. All 17 patients underwent local flap or muscle-cutaneous flap coverage procedure. After the surgery, the prosthetic vascular graft was successfully salvaged in 14 cases. The total successful rate was 82.4%. The surgery failed in three patients, in whom the prosthetic vascular grafts were finally removed. Local flap and transferred muscle-cutaneous flap reconstruction is an effective surgical management to salvage the exposed grafts.

  11. Preformed hydroxylapatite blocks for palatal grafting in orthognathic surgery.

    Science.gov (United States)

    Hiatt, W R; Moore, D L; Mosby, E L; Fain, D W

    1987-06-01

    Hydroxylapatite has been used as a bone substitute for ridge augmentation, ridge maintenance and periodontal defects for many years. This is a preliminary report of the use of hydroxylapatite blocks as a grafting material in midpalatal splits in orthognathic surgery. With the advent of hydroxylapatite blocks, the need for autogenous bone grafting will, in most cases, be obviated.

  12. Hemolytic anemia caused by kinking of dacron grafts implanted in ...

    African Journals Online (AJOL)

    Background: Hemolytic anemia caused by a kinked Dacron graft is a rare complication after repair of acute aortic dissection. We present a case of hemolytic anemia due to kinking of previously implanted Dacron graft for ascending aorta dissection treated by surgery and replaced with new Dacron. Case Details: We report a ...

  13. Graft Copolymerization Of Methyl Methacrylate Onto Agave Cellulose

    International Nuclear Information System (INIS)

    Noor Afizah Rosli; Ishak Ahmad; Ibrahim Abdullah; Farah Hannan Anuar

    2014-01-01

    The grafting polymerization of methyl methacrylate (MMA) and Agave cellulose was prepared and the grafting reaction conditions were optimized by varying the reaction time and temperature, and ratio of monomer to cellulose. The resulting graft copolymers were characterized by Fourier transform infrared, X-ray diffraction analysis, thermogravimetric analysis, and scanning electron microscopy (SEM). The experimental results showed that the optimal conditions were at a temperature of 45 degree Celsius for 90 min with ratio monomer to cellulose at 1:1 (g/ g). An additional peak at 1738 cm -1 which was attributed to the C=O of ester stretching vibration of poly(methyl methacrylate), appeared in the spectrum of grafted Agave cellulose. A slight decrease of crystallinity index upon grafting was found from 0.74 to 0.68 for cellulose and grafted cellulose, respectively. Grafting of MMA onto cellulose enhanced its thermal stability and SEM observation further furnished evidence of grafting MMA onto Agave cellulose with increasing cellulose diameter and surface roughness. (author)

  14. Forcasting Acha production in Nigeria: A comparison of grafted ...

    African Journals Online (AJOL)

    A grafted model (Quadratic-Quadratic-Linear) was estimated to forecast Acha output for periods outside the sample. The estimated structural parameters gave an R squared values of 0.81 and 0.99 for the linear and grafted respectively. Forecast were generated to evaluate the predictive performance of the estimated models ...

  15. Radiosensitivity of germs, grafts and vegetating potato plants

    International Nuclear Information System (INIS)

    Kutovenko, L.N.; Serebrenikov, V.S.

    1977-01-01

    Sensitivity of germs, grafts and vegetating potato plants to γ-radiation with doses of 1, 2, 3 and 5 kR has been investigated. While radiation dose increases the percentage of the survived buds and grafts decreases. Radiosensitivity of potato plants is affected not only by a radiation dose but also by the physiological state of the plant

  16. Vascularized fibular graft combined with vacuum assisted closure in ...

    African Journals Online (AJOL)

    The flowthrough fibular graft combined with Vacuum Assisted Closure (VAC) controlled the infection, shortened the course of treatment, and effectively restored limb function when applied to the treatment of tibial defects. Keywords: Tibial defect, Flow-through fibular graft, Vacuum Assisted Closure, Chronic Osteomyelitis ...

  17. Nipple-areolar complex (nac) composite grafts in the Management ...

    African Journals Online (AJOL)

    composite” graft. This is because the skin of the areola and especially the nipple are usually thicker than the case is in the usual full-thickness skin grafts (FTSG). In traditional breast reductions, the nipple-areolar complex is located to its new position ...

  18. Experimental studies in chickens on the initial nutrition of tendon grafts.

    Science.gov (United States)

    Manske, P R; Lesker, P A; Bridwell, K

    1979-11-01

    A study of nutrition of various tendon graft preparations in adult chickens (up to 2 weeks after grafting), using tritiated proline and a trichloracetic acid extraction technique which separated the free and metabolized amino acid fractions, suggests that diffusion of nutrients is an important process in the initial nutrition of tendon grafts, that tendon grafts are metabolically active and viable structures, that adhesions which are frequently associated with tendon grafts do not appear to be essential to the nutrition of grafts, and that tendon grafts within fibrous pseudosheaths are nourished as effectively as grafts within synovial sheaths.

  19. Composite vascular repair grafts via micro-imprinting and electrospinning

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yuanyuan, E-mail: yuanyuan-liu@shu.edu.cn; Hu, Qingxi, E-mail: huqingxi@shu.edu.cn [Rapid Manufacturing Engineering Center, Shanghai University, Shanghai 200444 (China); Shanghai Key Laboratory of Intelligent Manufacturing and Robotics, Shanghai 200072 (China); Xiang, Ke, E-mail: xiangke@shu.edu.cn; Chen, Haiping, E-mail: 519673062@qq.com; Li, Yu, E-mail: liyu@hpu.edu.cn [Rapid Manufacturing Engineering Center, Shanghai University, Shanghai 200444 (China)

    2015-04-15

    Composite vascular grafts formed by micro-imprinting and electrospinning exhibited improved mechanical properties relative to those formed by electrospinning alone. The three-layered composite grafts mimic the three-layered structure of natural blood vessels. The middle layer is made by micro-imprinting poly-p-dioxanone (PPDO), while the inner and outer layers are electrospun mixtures of chitosan and polyvinyl alcohol. The graft morphology is characterized with scanning electron microscopy. For constant graft thicknesses, the PPDO increases the mechanical strength. Cells cultivated on the vascular grafts adhere and proliferate better because of the natural, biological chitosan in the inner and outer layers. Overall, the composite scaffolds could be good candidates for blood vessel repair.

  20. Use and preservation methods of bone grafts in small animals

    Directory of Open Access Journals (Sweden)

    Rafael Garabet Agopian

    2016-09-01

    Full Text Available The present review describes the main characteristics of bone grafts used in small animals. Bone grafts are tissues without vasculature, which facilitate the production of new bone cells with osteogenic and osteoinductive factors that lead to the differentiation of cells and structural support for bone marrow. The transplant of a graft is followed by three stages: osteogenesis, or the formation of new bone; osteoinduction, which is the differentiation of cells; and osteoconduction, the process of growth of mesenchymal cells and capillaries that results in new bone formation. The composition of bone grafts may include spongy bone, cortical bone, cortical-spongy bone, cartilage or bone marrow. Grafts can also be classified according to their origin, being autogenous tissue when they are transplanted from the same individual, allogenous (homologous when originating from another individual of the same species, and xenogenous when obtained from a different species.

  1. Evaluation the success of osseointegrated implants in maxillary sinus grafts

    Directory of Open Access Journals (Sweden)

    Rubens Eduardo Gigli

    2008-01-01

    Full Text Available Objective: To analyze implants placed in maxillary sinus grafts with biomaterial of bovine origin and platelet-rich plasma, observing bone neoformation and the clinical and histologic success rate presented.Methods: Analysis of the clinical findings was based on 36 maxillary sinus grafts with 101 implants placed in 30 patients with a mean age of 47 years, and the histologic analysis, based on nine samples of the 36 grafts performed, with a mean interval of 7.5 months time of the graft, the majority of patients being men with a mean age of 42 years. Results: Clinically, 91 implants placed were osseointegrated.Conclusion: Based on the results presented, it was concluded that when implants are placed in the maxillary sinus region grafted with biomaterial, they present a high success rate. ISRCTN24003246

  2. Global DNA methylation changes in Cucurbitaceae inter-species grafting

    Directory of Open Access Journals (Sweden)

    Evangelia Avramidou

    2015-04-01

    Full Text Available Grafting has been used to improve yield, fruit quality and disease resistance in a range of tree and vegetable species. The molecular mechanisms underpinning grafting responses have only recently started to be delineated. One of those mechanisms involves long distance transfer of genetic material from rootstock to scion alluding to an epigenetic component to the grafting process. In the research presented herein we extended published work on heritable changes in the DNA methylation pattern of Solanaceae scion genomes, in Cucurbitaceae inter-species grafting. Specifically, we examined global DNA methylation changes in scions of cucumber, melon and watermelon heterografted onto pumpkin rootstocks using MSAP analysis. We observed a significant increase of global DNA methylation in cucumber and melon scions pointing to an epigenetic effect in Cucurbitaceae heterografting. Exploitation of differential epigenetic marking in different rootstock-scion combinations could lead to development of epi-molecular markers for generation and selection of superior quality grafted vegetables.

  3. Grafting: a technique to modify ion accumulation in horticultural crops

    Directory of Open Access Journals (Sweden)

    Muhammad Azher Nawaz

    2016-10-01

    Full Text Available Grafting is a centuries-old technique used in plants to obtain economic benefits. Grafting increases nutrient uptake and utilization efficiency in a number of plant species, including fruits, vegetables, and ornamentals. Selected rootstocks of the same species or close relatives are utilized in grafting. Rootstocks absorb more water and ions than self-rooted plants and transport these water and ions to the aboveground scion. Ion uptake is regulated by a complex communication mechanism between the scion and rootstock. Sugars, hormones, and miRNAs function as long-distance signaling molecules and regulate ion uptake and ion homeostasis by affecting the activity of ion transporters. This review summarizes available information on the effect of rootstock on nutrient uptake and utilization and the mechanisms involved. Information on specific nutrient-efficient rootstocks for different crops of commercial importance is also provided. Several other important approaches, such as interstocking (during double grafting, inarching, use of plant-growth-promoting rhizobacteria, use of arbuscular mycorrhizal fungi, use of plant growth substances (e.g., auxin and melatonin, and use of genetically engineered rootstocks and scions (transgrafting, are highlighted; these approaches can be combined with grafting to enhance nutrient uptake and utilization in commercially important plant species. Whether the rootstock and scion affect each other’s soil microbiota and their effect on the nutrient absorption of rootstocks remain largely unknown. Similarly, the physiological and molecular bases of grafting, crease formation, and incompatibility are not fully identified and require investigation. Grafting in horticultural crops can help reveal the basic biology of grafting, the reasons for incompatibility, sensing, and signaling of nutrients, ion uptake and transport, and the mechanism of heavy metal accumulation and restriction in rootstocks. Ion transporter and mi

  4. Grafting improves cucumber water stress tolerance in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Abdulaziz R. Al-Harbi

    2018-02-01

    Full Text Available Water scarcity is a major limiting factor for crop productivity in arid and semi-arid areas. Grafting elite commercial cultivars onto selected vigorous rootstocks is considered as a useful strategy to alleviate the impact of environmental stresses. This study aims to investigate the feasibility of using grafting to improve fruit yield and quality of cucumber under water stress conditions. Alosama F1 cucumber cultivar (Cucumis sativus L. was grafted onto Affyne (Cucumis sativus L. and Shintoza A90 (Cucurbitamaxima × C. moschata rootstocks. Non-grafted plants were used as control. All genotypes were grown under three surface drip irrigation regimes: 50%, 75% and 100% of the crop evapotranspiration (ETc, which represent high-water stress, moderate-water stress and non-water stress conditions, respectively. Yield and fruit quality traits were analyzed and assessed. In comparison to the non-grafted plants, the best grafting treatment under water stress was Alosama F1 grafted onto Shintoza A90 rootstock. It had an overall improved yield and fruit quality under water stress owing to an increase in the total fruit yield by 27%, from 4.815 kg plant−1 in non-grafted treatment to 6.149 kg plant−1 in grafted treatment under moderate -water stress, total soluble solid contents (13%, titratable acidity (39% and vitamin C (33%. The soil water contents were low in soil surface and increase gradually with soil depth, while salt distribution showed an adverse trend. The positive effects of grafting on plant growth, productivity, and water use efficiency support this strategy as an useful tool for improving water stress tolerance in greenhouse grown cucumber in Saudi Arabia.

  5. Coronary artery bypass grafts: assessment of graft patency and native coronary artery lesions using 16-slice MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Stauder, Norbert I.; Drosch, Tanja; Claussen, Claus D.; Kopp, Andreas F. [Eberhard-Karls-University, Department of Diagnostic Radiology, Tuebingen (Germany); Kuettner, Axel [Friedrich-Alexander-University, Department of Diagnostic Radiology, Erlangen (Germany); Schroeder, Stephen; Beck, Torsten [Eberhard-Karls-University, Department of Internal Medicine, Division Cardiology, Tuebingen (Germany); Stauder, Heidrun [Eberhard-Karls-University, Department of Thoracic and Cardiovascular Surgery, Tuebingen (Germany); Blumenstock, Gunnar [Eberhard-Karls-University, Department of Medical Information Processing, Tuebingen (Germany)

    2006-11-15

    The objective of this study was to evaluate the accuracy of electrocardiography (ECG)-gated 16-slice multidetector-row computed tomography (MDCT) in detection of stenosis of bypass grafts and native coronary arteries in patients who have undergone coronary artery bypass grafting (CABG). ECG-gated contrast-enhanced MDCT using 12 x 0.75-mm collimation was performed in 20 patients with recurrent angina 4.75 years after undergoing CABG. A total of 50 grafts, 16 arterial and 34 venous, were examined. All graft and coronary segments were evaluated for stenosis in comparison with conventional coronary angiography (CCA). Among the 80 arterial graft segments, 62 could be assessed (77.5%). Sensitivity, specificity, and positive and negative predictive values for stenosis were 96.2%, 97.2%, 96.2%, and 97.2%, respectively. In a total of 180 venous graft segments, 167 could be assessed. Sensitivity, specificity, and positive and negative predictive values for stenosis were 98.5%, 93.9%, 91.8%, and 98.9%, respectively. MDCT could assess 179 of 260 native coronary artery segments (68.8%).Sensitivity, specificity, and positive and negative predictive values for stenosis were 92.1%, 76.9%, 87.5%, and 84.7%, respectively. Sixteen-slice MDCT provides excellent image quality and diagnostic accuracy in detection of graft and coronary artery lesions in patients with suspected graft dysfunction. (orig.)

  6. Reinforcing the Mucoperiosteal Pocket with the Scarpa Fascia Graft in Secondary Alveolar Bone Grafting: A Retrospective Controlled Outcome Study.

    Science.gov (United States)

    Lonic, Daniel; Yamaguchi, Kazuaki; Chien-Jung Pai, Betty; Lo, Lun-Jou

    2017-10-01

    Secondary alveolar bone grafting is the gold standard for the treatment of alveolar clefts in cleft lip and palate patients. The authors present a modified method using a Scarpa fascia graft that is placed deep into the mucoperiosteal pocket for watertight sealing of the bone graft chamber and limiting the graft position to the alveolar region for bony stability and tooth support. The outcome was assessed for clinical success in terms of bone graft stability and infection rate. Seventy-four unilateral complete cleft lip and palate patients were enrolled in this retrospective study consisting of equal-size Scarpa fascia and control groups of consecutive unilateral complete cleft lip and palate patients undergoing secondary alveolar bone grafting. Occlusal radiographs of the alveolar cleft taken at least 1 year postoperatively were evaluated for Spearman correlated Bergland and Witherow scales. Statistical evaluation was conducted using t test, chi-square test, and odds ratio. The clinical success rate (Bergland types I and II) of the Scarpa fascia procedure was significantly higher (67.6 versus 94.6 percent, respectively), with a significantly lower infection rate (16.2 versus 2.7 percent, respectively) and a high correlation of Bergland and Witherow scales (0.964; p fascia group. The authors' new method of alveolar bone grafting with the Scarpa fascia graft is safe and effective, and has one of the highest documented success rates. Therapeutic, III.

  7. Determination of grafting conversion degree in PS/PS-graft-POSS/POSS hybrid nanocomposites obtained through reactive processing

    International Nuclear Information System (INIS)

    Bianchi, Otavio; Repenning, Gustavo B.; Mauler, Raquel S.; Oliveira, Ricardo V.B.; Canto, Leonardo B.

    2011-01-01

    Hybrid nanocomposites of polystyrene (PS) and polyhedral oligomeric silsesquioxanes (POSS) - PS/PS-graft-POSS/POSS - with different grafting degrees were prepared by reactive melt processing using dicumyl peroxide (DCP) as initiator in the presence or absence of styrene monomer as radical transfer agent. Gel permeation chromatography (GPC) using triple-detector and proton nuclear magnetic resonance (NMR 1 H) analyses were used together to determine the conversion degree of PS-graft-POSS as a function of the reactive processing conditions adopted. GPC was employed to evaluate the effects of grafting (PS-graft-POSS) and PS chains degradation (β scission) that occur simultaneously during processing on the variation of average molecular masses and distributions for each PS/POSS sample. PS/POSS systems processed with styrene showed higher weight average molecular weights (M w ) and lower polydispersity indexes (M w /M n ), as a result of higher grafting (PS-graft-POSS) conversion (28-40%) and lower PS chain degradation level, as compared to PS/POSS systems processed without styrene in which the degree of grafting conversion was around 25-28%. (author)

  8. Enhancement of the grafting performance and of the water absorption of cassava starch graft copolymer by gamma radiation

    International Nuclear Information System (INIS)

    Kiatkamjornwong, Suda; Meechai, Nispa

    1997-01-01

    Enhancement of the gamma radiation grafting of acrylonitrile onto gelatinized cassava starch was investigated. Infrared spectrometry was used to follow the chemical changes in the grafting reaction and from saponification. The saponified starch-g-PAN (HSPAN) was then characterized in terms of grafting parameters to provide a guide for the optimum total dose (kGy) and the appropriate ratio of starch/acrylonitrile for a fixed dose rate of 2.5 x 10 -1 kGy/min. Other dose rates were also carried out to obtain the appropriate result of grafting copolymerization and of water absorption. A thin aluminium foil, covering the inner wall of the reaction vessel, was found to be far more effective than any other metal films in the enhancement of the grafting reaction and the water absorption as well. Nitric acid in the medium increases the grafting yield and the water absorption. Methyl ether hydroquinone inhibitor was evaluated for its ability to increase homopolymerization and decrease graft reaction. When styrene was used as a comonomer, it hampered the grafting of acrylonitrile onto starch backbone. The water absorption capacity was improved by freeze-drying the HSPAN. The treatment of the HSPAN with aluminium trichloride hexahydrate was found to enhance the degree of wicking, but to decrease the water absorbency. (author)

  9. Long-term graft outcome of pediatric liver transplantation in Copenhagen

    DEFF Research Database (Denmark)

    Yamauchi, Yasushi; Yamashita, Yuichi; Wettergren, Andre

    2006-01-01

    BACKGROUND: Graft loss after liver transplantation remains a significant problem, especially in pediatric patients. The aim of this study was to assess our initial series of pediatric liver transplantation and to identify the risk factors that influence graft outcome. METHODS: The first 51...... transplantations were analyzed retrospectively. All transplantations were stratified into three groups according to graft type (full-size, reduced-size, and living-related-donor graft). Survival data of the grafts were stratified and multivariate analysis conducted with respect to preoperative and surgical factors....... RESULTS: Seventeen of all the transplants were full-size grafts and 34 technical-variant grafts (27 reduced-size grafts from cadavers and 7 living-related-donor grafts). The overall graft survival rates were 65, 62 and 53% at 1, 3 and 5 years, respectively. Twenty-three of 51 grafts (45%) were lost. Poor...

  10. Vancomycin graft composite for infected bone defects

    International Nuclear Information System (INIS)

    Winkler, H.; Janata, O.; Georgopoulos, A.

    1999-01-01

    Reconstructive surgery under septic conditions represents a major challenge in orthopaedics. Local application of antibiotics can provide high drug levels at the site of infection without systemic effects. However, removal of non-resorbable implants and filling of defects usually requires additional operative procedures. An ideal antibiotic carrier should provide for : 1) Effective bactericidal activity, especially against staphylococci including MRSA; 2) High and long lasting levels at the site of infection without local or systemic toxicity; 3) Repair of defects without a second stage procedure. Allogeneic cancellous bone is proven to be effective in restoration of bone stock. Vancomycin is effective against all gram-positive populations and the agent of choice for infections with MRSA. The aim of our study is to investigate the efficacy of a combination of both components in bone infection. Cancellous bone of human origin was processed during several steps and incubated in 10% vancomycin solution. The antimicrobial activity of the vancomycin graft composite (VGC) was evaluated using an agar diffusion bioassay against staphylococcus aureus and high performance liquid chromatography (HPLC). The testing period was up to 9 weeks. Elution of vancomycin from the graft was evaluated in 2.5% human albumin solution, which was exchanged every 24 hours. Concentration of vancomycin in allograft-bone was between 6.653[tg/g and 23.194gg/g with an average of 15.250 [tg/g, which is equivalent to 10.000 times the minimum inhibitory concentration (MIC) for s. aureus. The initial activity decreased to approx. 50% during the first week and approx. 30% at the end of the 9th week. The lowest values measured exceeded the MIC by 2000 times. Concentration in surrounding fluid decreased from 24.395,80 to 18,43pg/ml after 11 complete exchanges. Human cancellous bone, processed in an adequate way, offers capability to store high quantities of vancomycin. Vancomycin graft composites are

  11. Differential contributions of graft-derived and host-derived cells in tissue regeneration/remodeling after fat grafting.

    Science.gov (United States)

    Doi, Kentaro; Ogata, Fusa; Eto, Hitomi; Kato, Harunosuke; Kuno, Shinichiro; Kinoshita, Kahori; Kanayama, Koji; Feng, Jingwei; Manabe, Ichiro; Yoshimura, Kotaro

    2015-06-01

    Recent research indicates that the adipose tissue of nonvascularized grafts is completely remodeled within 3 months, although origins of next-generation cells are unclear. Inguinal fat pads of green fluorescent protein mice and wild-type mice were cross-transplanted beneath the scalp. At 1, 2, 4, and 12 weeks after transplantation, grafted fat was harvested, weighed, and analyzed through immunohistochemistry, whole-mount staining, and flow cytometry of cell isolates. Bone marrow of green fluorescent protein mice was transplanted to wild-type mice (after irradiation). Eight weeks later, these mice also received fat grafts, which were analyzed as well. The majority of host-derived cells detected during remodeling of grafted fat were macrophages (>90 percent at the early stage; 60 percent at 12 weeks). Cell origins were analyzed at 12 weeks (i.e., when completely regenerated). At this point, mature adipocytes were largely derived from adipose-derived stem/stromal cells of grafts. Although vascular wall constituents were chiefly graft derived, vascular endothelial cells originated equally from graft and host bone marrow. Adipose-derived stem/stromal cells of regenerated fat were an admixture of grafted, host nonbone marrow, and host bone marrow cells. The above findings underscore the importance of adipose stem/stromal cells in the grafted fat for adipocyte regeneration. Host bone marrow and local tissues contributed substantially to capillary networks and provided new adipose-derived stem/stromal cells. An appreciation of mechanisms that are operant in this setting stands to improve clinical outcomes of fat grafting and cell-based therapies.

  12. PEM Anchorage on Titanium Using Catechol Grafting

    Science.gov (United States)

    Marie, Hélène; Barrere, Amélie; Schoentstein, Frédérique; Chavanne, Marie-Hélène; Grosgogeat, Brigitte; Mora, Laurence

    2012-01-01

    Background This study deals with the anchorage of polyelectrolyte films onto titanium surfaces via a cathecol-based linker for biomedical applications. Methodology The following study uses a molecule functionalized with a catechol and a carboxylic acid: 3-(3,4-dihydroxyphenyl)propanoic acid. This molecule is anchored to the TiO2 substrate via the catechol while the carboxylic acid reacts with polymers bearing amine groups. By providing a film anchorage of chemisorption type, it makes possible to deposit polyelectrolytes on the surface of titanium. Principal Findings Infrared spectroscopy (ATR-FTIR), X-ray photoelectron spectroscopy (XPS), contact angle and atomic force microscopy (AFM) measurements show that the different steps of grafting have been successfully performed. Conclusions This method based on catechol anchorage of polyelectrolytes open a window towards large possibilities of clinical applications. PMID:23226262

  13. Patency rates and complications of Exxcel yarn-wrapped polytetrafluoroethylene grafts versus Gore-tex stretch polytetrafluoroethylene grafts: a prospective study.

    Science.gov (United States)

    Ko, Po-Jen; Hsieh, Hung-Chang; Chu, Jaw-Ji; Lin, Pyng Jing; Liu, Yun-Hen

    2004-01-01

    Polytetrafluoroethylene (PTFE) has long been used for hemodialysis access when there is no suitable superficial vein. We conducted a prospective randomized study to compare two PTFE grafts; the stretch Gore-tex graft and the Exxcel graft. Between May 2000 and February 2001, PTFE grafts were implanted for hemodialysis access in the upper extremities of 94 consecutive patients with end-stage renal disease. Graft selection was randomized, with patients receiving either a Gore-tex or an Exxcel graft. All grafts were monitored for signs of thrombosis or other complications. Graft survival was analyzed using a life-table analysis and the log-rank test was applied to compare graft patency. The primary patency rates 1 and 2 years after implantation were 51% and 36% for the Exxcel grafts, and 71% and 45% for the Gore-tex grafts, respectively. The difference between the two groups was not significant at any time. The incidence of complications needing further surgical management was 8.2% in the Exxcel group and 6.7% in the Gore-tex group, without a significant difference. Exxcel grafts or Gore-tex stretch grafts can be used for dialysis access with similar expected outcomes for up to 2 years, despite the differences in their outer surface design. The yarn-wrapped design does not appear to enhance the graft patency and we found no remarkable difference.

  14. Lycopene and flesh colour differences in grafted and non-grafted watermelon

    Directory of Open Access Journals (Sweden)

    Fekete D.

    2015-01-01

    Full Text Available The experiment was carried out in three regions in Hungary (Jászszentandrás, Cece, Újkígyós in 2013 to determine the fruit quality of grafted watermelon (Citrullus lanatus Thunb.. The “RX 467” seedless watermelon variety was grafted on two commercial rootstocks “FR STRONG” [Lagenaria siceraria (Mol. Standl.] and “RS 841” (Cucurbita maxima Duchesne × Cucurbita moschata Duchesne. The lycopene and flesh colours are important quality characteristics even of the selfrooted and grafted watermelon. Some differences can be attributed to different environments, technological methods and to the type of rootstockscion combination. Lycopene is a strong antioxidant; therefore, we considered to examine the content change. Regardless of growing location, the lycopene concentration and the chroma (C* showed the best result in the case of interspecific rootstock. The result also showed that in two regions (Jászszentandrás, Cece we can find negative correlation between the lycopene concentration and the L* value of the flesh colour.

  15. The composite aortic wall graft technique: an option for a short coronary artery bypass graft

    Directory of Open Access Journals (Sweden)

    João Bosco de Oliveira

    2009-01-01

    Full Text Available SUMMARY: During coronary artery bypass graft (CABG surgery, the saphenous vein is sutured through its proximal segment to the aorta. Intimal hyperplasia is one of the possible causes of graft occlusion. Notably, blood turbulence can induce wall shear stress that may also play an important role in this process. OBJECTIVE: We propose a new technique for performing proximal anastomosis to avoid CABG failure. METHOD: An 80 kg pig was subjected to open heart surgery. Four stitches were placed in the anterior ascending aorta, which formed a 2 cm by 4 cm patch. This patch was isolated through the application of a tangential clamp that was oriented parallel to the axis of the aorta. After releasing the patch, which was held to the aorta through its cranial end pedicle, the rims were sutured to each other creating a conduit with a length of 4 cm and an internal diameter of 4 mm. The rest of the aortotomy was closed by placing a direct suture between its rims. RESULT: This novel technique created an "in situ" aortic wall graft that was 4 cm long and characterized as being of uniform 4 mm caliber.

  16. Vascularized fibular graft in infected tibial bone loss

    Directory of Open Access Journals (Sweden)

    C Cheriyan Kovoor

    2011-01-01

    Full Text Available Background : The treatment options of bone loss with infections include bone transport with external fixators, vascularized bone grafts, non-vascularized autogenous grafts and vascularized allografts. The research hypothesis was that the graft length and intact ipsilateral fibula influenced hypertrophy and stress fracture. We retrospectively studied the graft hypertrophy in 15 patients, in whom vascularized fibular graft was done for post-traumatic tibial defects with infection. Materials and Methods : 15 male patients with mean age 33.7 years (range 18 - 56 years of post traumatic tibial bone loss were analysed. The mean bony defect was 14.5 cm (range 6.5 - 20 cm. The mean length of the graft was 16.7 cm (range 11.5 - 21 cm. The osteoseptocutaneous flap (bone flap with attached overlying skin flap from the contralateral side was used in all patients except one. The graft was fixed to the recipient bone at both ends by one or two AO cortical screws, supplemented by a monolateral external fixator. A standard postoperative protocol was followed in all patients. The hypertrophy percentage of the vascularized fibular graft was calculated by a modification of the formula described by El-Gammal. The followup period averaged 46.5 months (range 24 - 164 months. The Pearson correlation coefficient (r was worked out, to find the relationship between graft length and hypertrophy. The t-test was performed to find out if there was any significant difference in the graft length of those who had a stress fracture and those who did not and to find out whether there was any significant difference in hypertrophy with and without ipsilateral fibula union. The Chi square test was performed to identify whether there was any association between the stress fracture and the fibula union. Given the small sample size we have not used any statistical analysis to determine the relation between the percentage of the graft hypertrophy and stress fracture. Results : Graft

  17. Radiation-induced grafting of styrene on polypropylene pellets

    International Nuclear Information System (INIS)

    Souza, Camila P.; Ferreira, Henrique P.; Parra, Duclerc F.; Lugao, Ademar B.

    2009-01-01

    The changes of radiation-induced in polypropylene (PP) pellets exposed to gamma irradiation in inert atmosphere were investigated in correlation with the applied doses (10 and 50 kGy). Also, results from the grafting of styrene onto PP pellets using simultaneous irradiation at the same doses are presented. The grafting reaction was carried out using toluene as solvent, under nitrogen atmosphere and at room temperature. The properties of the irradiated and grafted PP pellets were studied using Melt Flow Index, thermal analysis (TG and DSC), and ATR-IR. The degree of grafting (DOG) for the grafted pellets was gravimetrically determined. The results showed that radiation-induced graft polymerization on pellets were successfully obtained and the influence of dose irradiated did not change the thermal properties in spite of the increase in the MFI and consequently this increase in the viscosity results an decrease the molecular mass. The MFI for grafted pellets was not achievable because the high degree of viscosity of polymer, even arising the test temperature, the polymer was not flow enough. (author)

  18. Computed tomography evaluation of autogenous graft in sinus lift surgery

    International Nuclear Information System (INIS)

    Ajzen, Sergio Aron; Moscatiello, Rafael Andrade; Lima, Aida Maria Custodio de; Moscatiello, Vitoria Aparecida Muglia; Helio Kiitiro Yamashita; Mosacatiello, Rafael Muglia; Nishiguchi, Celso Itiro; Alves, Maria Teresa de Seixas

    2001-01-01

    The objective was to quantify bone formation within autogenous bone grafts and autogenous bone grafts in combination with platelet-rich plasma obtained either from apheresis or centrifugation using computed tomography. This prospective, double-blind study was conducted in 34 male and female adult patients (mean age of 28 years and 8 months), with either unilateral or bilateral pneumatization of the maxillary sinuses, requiring bone graft for dental implant. All patients were submitted to computed tomography examinations prior and six months after sinus lift surgery. Fifty-three maxillary sinuses were operated and divided into three distinct groups: autogenous bone graft, autogenous bone graft in combination with platelet-rich plasma obtained by centrifugation, and autogenous bone graft in combination with platelet-rich plasma obtained by apheresis. The results showed that computed tomography demonstrated bone growth in height and width between the initial and the follow-up computed tomography scans in all three groups. However, no statistical difference was found either for bone height or width. It was concluded that clinical evidence demonstrates the effectiveness of autogenous bone grafts, particularly when used in combination with bone growth factors such as platelet-rich plasma, which allow prosthetic and functional restoration of maxillofacial structures through fixation of dental implants. (author)

  19. Characterization of adipose tissue for autologous fat grafting.

    Science.gov (United States)

    Suszynski, Thomas M; Sieber, David A; Van Beek, Allen L; Cunningham, Bruce L

    2015-02-01

    Fat grafting is a common procedure in aesthetic and reconstructive plastic surgery, but variable graft retention limits its utility. Unpredictable clinical outcomes with fat grafting can be explained in part by the lack of standardized protocols for harvesting, processing, and transplanting adipose tissue (AT). Historically, plastic surgeons have relied on trial and error and their clinical experience to develop fat grafting protocols. Optimization of fat grafting protocols requires systematic assessment of the impact that key variables have on the quality of the AT preparation at each step of the procedure. In this article, we review recent findings regarding the composition and quality of AT prepared for fat grafting and the strengths and limitations of existing AT characterization assays. We discuss the need for an assessment of the viability of intact AT (ie, conventionally harvested AT that has not been disrupted further) by means of an operator-independent, quantitative assay that can be performed in real time and generates reproducible data. Promising assays for the characterization of cell product quality have been developed for other therapeutic applications, such as transplantation of pancreatic islet cells. The development or adaptation of a gold-standard assay to determine the quality of an AT preparation may help to standardize fat grafting protocols and improve clinical outcomes. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  20. A multilayered electrospun graft as vascular access for hemodialysis.

    Science.gov (United States)

    Radakovic, D; Reboredo, J; Helm, M; Weigel, T; Schürlein, S; Kupczyk, E; Leyh, R G; Walles, H; Hansmann, J

    2017-01-01

    Despite medical achievements, the number of patients with end-stage kidney disease keeps steadily raising, thereby entailing a high number of surgical and interventional procedures to establish and maintain arteriovenous vascular access for hemodialysis. Due to vascular disease, aneurysms or infection, the preferred access-an autogenous arteriovenous fistula-is not always available and appropriate. Moreover, when replacing small diameter blood vessels, synthetic vascular grafts possess well-known disadvantages. A continuous multilayered gradient electrospinning was used to produce vascular grafts made of collagen type I nanofibers on luminal and adventitial graft side, and poly-ɛ-caprolactone as medial layer. Therefore, a custom-made electrospinner with robust environmental control was developed. The morphology of electrospun grafts was characterized by scanning electron microscopy and measurement of mechanical properties. Human microvascular endothelial cells were cultured in the graft under static culture conditions and compared to cultures obtained from dynamic continuous flow bioreactors. Immunofluorescent analysis showed that endothelial cells form a continuous luminal layer and functional characteristics were confirmed by uptake of acetylated low-density-lipoprotein. Incorporation of vancomycin and gentamicin to the medial graft layer allowed antimicrobial inhibition without exhibiting an adverse impact on cell viability. Most striking a physiological hemocompatibility was achieved for the multilayered grafts.

  1. Post-transplant glomerulopathy impact in renal graft survival

    Directory of Open Access Journals (Sweden)

    Nora Imperiali

    2014-12-01

    Full Text Available Introduction: Primary glomerulopathy is cause of renal chronic disease in renal transplant recipients (30%-50%, being an important determinant in graft survival. Recent studies reveal that recurrence was the third most frequent cause of graft lost after 10 years post-transplant monitoring process. Objective: To analyze posttransplant glomerulopathy impact as a graft lost predictor. Methods: Between January 1990 and April 2013, 849 renal biopsies were carried out on 375 transplanted patients, 50 glomerulopathy cases were diagnosed. This population was compared with an historical renal transplant recipients group between 2000 to 2011, without glomerulopathy. Renal graft survival was analyzed in both populations. Results: 50 post-transplant glomerulopathies were diagnosed in 47 patients. We did not find statistically significant differences between this group and the historical one concerning recipient age, donor sex, donor type, miss match number, organ ischaemia time, acute rejection rate, delayed graft function, and neither in the recipient mortality. We did find significant differences in male sex, 88% vs 55% (p≤ 0.05. Renal graft lost rate was significantly more frequent among patients presenting glomerular disease 38 vs 8 % (p ≤ 0.01. Conclusion: In our population, post transplant glomerulopathy was associated to graft survival reduction and a higher membranoproliferative glomerulopathy lost rate was observed.

  2. Chronologic changes of free fat graft in rabbit using CT

    International Nuclear Information System (INIS)

    Kondo, Norihiro; Kurita, Kenichi; Yajima, Tetsuya; Izumi, Masahiro

    2008-01-01

    Free fat grafts are now used for preventing osteal readhesion, filling dead space, and protecting grafted nerves and vessels. However, it is reported that grafted fat tissue is unstable resulting in high risk of cicatrization and infection. We grafted free fat to a rabbit's back and observed the chronologic change using CT. Ten adult male Japanese white rabbits (3.5 kg) were used. In five rabbits, fat tissue was obtained from the back under general anaesthesia, and transplanted into the back about 50 mm posterior from the donor site. CT was taken in the fixed scan condition five times (preoperation, immediate postoperation, postoperative 1-month, 2-month, and 3-month). In the remaining five rabbits, only CT scan was taken three times as a control. It was observed that we compared preoperative fat volume with the postoperative volume using RealINTAGE. Grafted fat tissue decreased postoperatively at 1-month and completely disappeared at 3-months. We were able to prove that CT scan is effective to observe the chronologic change of grafted fat tissue. Techniques of tissue engineering are necessary for survival of grafted fat tissue. (author)

  3. Proximal tubular dysfunction as an indicator of chronic graft dysfunction

    Directory of Open Access Journals (Sweden)

    N.O.S. Câmara

    2009-03-01

    Full Text Available New strategies are being devised to limit the impact of renal sclerosis on graft function. Individualization of immunosuppression, specifically the interruption of calcineurin-inhibitors has been tried in order to promote better graft survival once chronic graft dysfunction has been established. However, the long-term impact of these approaches is still not totally clear. Nevertheless, patients at higher risk for tubular atrophy and interstitial fibrosis (TA/IF development should be carefully monitored for tubular function as well as glomerular performance. Since tubular-interstitial impairment is an early event in TA/IF pathogenesis and associated with graft function, it seems reasonable that strategies directed at assessing tubular structural integrity and function would yield important functional and prognostic data. The measurement of small proteins in urine such as α-1-microglobulin, N-acetyl-beta-D-glucosaminidase, alpha/pi S-glutathione transferases, β-2 microglobulin, and retinol binding protein is associated with proximal tubular cell dysfunction. Therefore, its straightforward assessment could provide a powerful tool in patient monitoring and ongoing clinical assessment of graft function, ultimately helping to facilitate longer patient and graft survival associated with good graft function.

  4. Three-dimensional volumetric analysis after sinus grafts.

    Science.gov (United States)

    Kim, Eun-Sik; Moon, Seong-Yong; Kim, Su-Gwan; Park, Hyun-Chun; Oh, Ji-Su

    2013-04-01

    The purpose of this study was to evaluate the augmentation volume of a sinus graft according to the time and graft materials based on cone-beam computed tomography (CBCT) scans and to assess efficacy of a bioabsorbable membrane. Fourteen patients were investigated, and volumetric analysis was performed using OnDemand 3DTM software (Cybermed, Seoul, Korea). CBCT scans were performed on patients before surgery, immediately after surgery, 6 months after surgery, and 1 year after surgery. Following this analysis, the volumetric data were compared with the actual grafted volumes. Bioabsorbable membranes were used in all patients to promote the protection of sinus membranes and to guide bone regeneration. Overall, the average percent volume of graft material that remained 6 months after implantation was 82.0%, and the average percent volume of graft material that remained 1 year after surgery was 60.4%. These reductions in the volume of graft material from immediately after surgery until 6 months or 1 year after surgery were shown to be statistically significant (P = 0.002 and P volumetric analysis performed using CBCT can provide highly accurate data. A significant difference was observed in volumetric change over time, but no significant differences were observed between materials. No significant relationship was observed between the resorption of grafted bone and the success rate.

  5. A classification of clinical fat grafting: different problems, different solutions.

    Science.gov (United States)

    Del Vecchio, Daniel; Rohrich, Rod J

    2012-09-01

    Fat grafting has reemerged from a highly variable procedure to a technique with vast reconstructive and cosmetic potential. Largely because of a more disciplined and scientific approach to fat grafting as a transplantation event, early adopters of fat transplantation have begun to approach fat grafting as a process, using sound surgical transplantation principles: recipient preparation, controlled donor harvest, time-efficient transplantation, and proper postoperative care. Despite these principles, different fat grafting techniques yield impressive clinical outcomes. The essential variables of four types of fat grafting cases were identified and compared: harvesting, methods of cell processing, methods of transplantation, and management of the recipient site. Each case differed for most of the variables analyzed. The two clinical drivers that most impacted these differences were the volume demands of the recipient site and whether the recipient site was healthy tissue or pathologic tissue. After these two drivers, a matrix classification of small-volume versus large-volume and regenerative versus nonregenerative cases yields four distinct categories. Not all fat grafting is the same. Fat grafting, once thought to be a simple technique with variable results, is a much more complex procedure with at least four definable subtypes. By defining the essential differences in the recipient site, the key driver in fat transplantation, the proper selection of technique can be best chosen. In fat transplantation, different problems require different solutions.

  6. Sulfonated Poly(styrene) Chains Grafted on Magnetic Nanoparticles

    Science.gov (United States)

    Jiao, Yang; Yevelev, Anton; Parra, Javier; Akcora, Pinar; Stevens Institute of Technology Team

    2014-03-01

    Iron oxide nanoparticles functionalized with poly(styrene) (PS) chains at various grafting densities and loadings present stable and ordered nanostructures for tuning the mechanical and conductive properties in polymer composites. Strings, spherical and anisotropic clusters and well-dispersed particles are achieved with PS-grafted Fe3O4 nanoparticles in PS matrices upon varying the system parameters. In this work, we report the effect of sulfonic group locations on the aggregation state of polymer-grafted nanoparticles. Structures formed by the random and diblock copolymers of PS-poly(styrene sulfonate) (PSS) grafted particles will be discussed with small-angle x-ray scattering (SAXS) measurements in solution and melts. The conformational changes in PS-grafted chains and ion-containing grafts will be also presented in small-angle neutron-scattering (SANS) results to understand the role of polymer on the assembly of particles at the low grafting density. We acknowledge support by NSF-CAREER-DMR (#1048865).

  7. Grafted polymer chains suppress nanoparticle diffusion in athermal polymer melts

    Science.gov (United States)

    Lin, Chia-Chun; Griffin, Philip J.; Chao, Huikuan; Hore, Michael J. A.; Ohno, Kohji; Clarke, Nigel; Riggleman, Robert A.; Winey, Karen I.; Composto, Russell J.

    2017-05-01

    We measure the center-of-mass diffusion of poly(methyl methacrylate) (PMMA)-grafted nanoparticles (NPs) in unentangled to slightly entangled PMMA melts using Rutherford backscattering spectrometry. These grafted NPs diffuse ˜100 times slower than predicted by the Stokes-Einstein relation assuming a viscosity equal to bulk PMMA and a hydrodynamic NP size equal to the NP core diameter, 2Rcore = 4.3 nm. This slow NP diffusion is consistent with an increased effective NP size, 2Reff ≈ 20 nm, nominally independent of the range of grafting density and matrix molecular weights explored in this study. Comparing these experimental results to a modified Daoud-Cotton scaling estimate for the brush thickness as well as dynamic mean field simulations of polymer-grafted NPs in athermal polymer melts, we find that 2Reff is in quantitative agreement with the size of the NP core plus the extended grafted chains. Our results suggest that grafted polymer chains of moderate molecular weight and grafting density may alter the NP diffusion mechanism in polymer melts, primarily by increasing the NP effective size.

  8. Albumin grafting on biomaterial surfaces using gamma-irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Kamath, K.R.

    1993-01-01

    Surface modification has been used extensively in various fields to introduce desirable surface properties without affecting the bulk properties of the material. In the area of biomaterials, the approach of surface modification offers an effective alternative to the synthesis of new biomaterials. The specific objective of this study was to modify different biomaterial surfaces by albumin grafting to improve their blood compatibility. The modified surfaces were characterized for surface-induced platelet activation and thrombus formation. This behavior was correlated with the conditions used for grafting. In particular, albumin was functionalized to introduce pendant double bonds into the molecule. The functionalized albumin was covalently attached to various surfaces, such as dimethyldichlorosilane-coated glass, polypropylene, polycarbonate, poly(vinyl chloride), and polyethylene by gamma-irradiation. Platelet adhesion and activation on these surfaces was examined using video microscopy and scanning electron microscopy. The extent of grafting was found to be dependent on the albumin concentration used for adsorption and the gamma-irradiation time. Release of the grafted albumin during exposure to blood was minimal. The albumin-grafted fibers maintained their thromboresistant properties even after storage at elevated temperatures for prolonged time periods. Finally, the approach was used to graft albumin on the PLEXUS Adult Hollow Fiber Oxygenators (Shiley). The blood compatibility of the grafted oxygenators improved significantly when compared to controls.

  9. Improvement of the polymer stability by radiation grafting

    International Nuclear Information System (INIS)

    Ranogajec, F.; Mlinac-Misak, M.

    2004-01-01

    Losses of the stabilizer due to extractability or volatility immediately affect the ultimate performance of polymer products. A new approach to increase the persistence of the stabilizer in the final product is to chemically bind it to the polymer backbone. Radiation grafting or crosslinking could be an efficient method for this, when the stabilizer is polymerizable. By a mutual gamma irradiation method photoprotector 2-hydroxy-4-(3-methacryloxy-2-hydroxy-propoxy) benzophenone has been readily grafted to low-density polyethylene in benzene, tetrahydrofuran and methanol solution, respectively. Surface grafting occurs in a methanol solution of stabilizer, while in benzene and tetrahydrofuran solutions of the stabilizer, grafting proceeds more or less in the inner parts of the polymeric film as well. UV stability tests and changes in the mechanical properties of artificially and naturally aged films indicate pronounced protective effect achieved by the grafted stabilizer. Surface grafting is an efficient photostabilization method since the grafted stabilizer is chemically bound to a polymeric surface and in this way the problem of evaporation of blended stabilizers during the prolonged use of polymeric materials is eliminated

  10. Analysis of Cartilage-Polydioxanone Foil Composite Grafts

    Science.gov (United States)

    Kim, James H.; Wong, Brian

    2014-01-01

    This study presents an analytical investigation into the mechanical behavior of a cartilage-polydioxanone (PDS) plate composite grafts. Numerical methods are used to provide a first-order, numerical model of the flexural stiffness of a cartilage-PDS graft. Flexural stiffness is a measure of resistance to bending and is inversely related to the amount of deformation a structure may experience when subjected to bending forces. The cartilage-PDS graft was modeled as a single composite beam. Using Bernoulli-Euler beam theory, a closed form equation for the theoretical flexural stiffness of the composite graft was developed. A parametric analysis was performed to see how the flexural properties of the composite model changed with varying thicknesses of PDS foil. The stiffness of the cartilage-PDS composite using 0.15-mm-thick PDS was four times higher than cartilage alone. The composite with a 0.5-mm-thick PDS graft was only 1.7 times stiffer than the composite with the 0.15-mm-thick PDS graft. Although a thicker graft material will yield higher flexural stiffness for the composite, the relationship between composite stiffness and PDS thickness is nonlinear. After a critical point, increments in graft thickness produce gradually smaller improvements in flexural stiffness. The small increase in stiffness when using the thicker PDS foils versus the 0.15 mm PDS foil may not be worth the potential complications (prolonged foreign body reaction, reduction in nutrient diffusion to cartilage) of using thicker artificial grafts. PMID:24327249

  11. Adequacy of palmaris longus and plantaris tendons for tendon grafting.

    Science.gov (United States)

    Jakubietz, Michael G; Jakubietz, Danni F; Gruenert, Joerg G; Zahn, Robert; Meffert, Rainer H; Jakubietz, Rafael G

    2011-04-01

    The reconstruction of tendon defects is challenging. The palmaris longus and plantaris tendon are generally considered best for tendon grafting. Only a few studies have examined whether these tendons, when present, meet criteria for successful grafting. The purpose of this study was to evaluate these tendons in regard to adequacy as tendon grafts. To evaluate adequacy for grafting, the palmaris longus and plantaris tendons were harvested from 92 arms and legs of 46 cadavers. Macroscopic evaluation and measurements concerning presence, length, and diameter of the tendons were obtained. Criteria for adequacy were a minimum length of 15 cm with diameter of 3 mm or, alternatively, 30 cm with a diameter of 1.5 mm. The palmaris longus tendon was present bilaterally in 36 cases and was absent bilaterally in 4 cases. The plantaris tendon was present bilaterally in 38 cases and absent bilaterally in 4 cases. In 29 cadavers, the palmaris longus tendon did not meet the criteria to be used as a tendon graft. Only in 8 cases were the tendons satisfactory for grafting bilaterally. The plantaris tendon met criteria for grafting in 20 cases bilaterally. In 17 cases, the tendons were considered inadequate bilaterally. Despite their presence, the palmaris longus and plantaris tendons are adequate for grafting less often than previously thought. In less than 50%, the tendons, although present, would serve as useful grafts. Our findings underscore the importance of choosing a second donor site before surgery in case the primarily selected tendon is not found to be suitable. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  12. Mandibular defect reconstruction with nonvascularized iliac crest bone graft.

    Science.gov (United States)

    Okoje, V N; Obimakinde, O S; Arotiba, J T; Fasola, A O; Ogunlade, S O; Obiechina, A E

    2012-01-01

    Reconstruction of mandibular defect is a challenge to the head and neck surgeon because of associated functional and esthetic problems. Our experience with the use of nonvascularized iliac crest bone graft is hereby reported. The aim was to report our experience with the use of nonvascularized iliac crest bone for mandibular defect reconstruction at University College Hospital, Ibadan. Nigeria. A retrospective descriptive study was performed. Cases of mandibular reconstruction with iliac crest bone graft between January 2001 and December 2007 were included in this study. Grafts were secured with either a stainless steel wire or a titanium plate. Preoperative diagnosis, postoperative follow-up records including investigations, diagnosis of graft infection and subsequent treatment modalities were extracted from the available records. Descriptive variables were analyzed with SPSS version 14. A total of 47 patients had mandibular defect reconstruction with nonvascularized iliac crest block bone during the study period. Thirty-eight patients had graft secured with transosseous wire [NVIBw] while 9 had a titanium plate [NVIBp]. The male:female ratio was 26:21 while the mean age of the patients was 24.6±4.25 years. Ten patients (21.3%) developed persistent graft infection during the postoperative period. All cases of infection occurred in patients who had transosseous wiring and analysis showed that 60% of the infected grafts revealed mixed microbial isolates containing Klebsiela spp, Pseudomonas Aeurogenosa, and E coli. Six (60%) of the infected grafts were removed as a result of unabated infection while 4 (40%) were successfully treated by exploration and pus drainage. Nonvascularized iliac crest bone graft provides an affordable and less technical choice for mandibular reconstruction with minimal complications in a resource-limited economy.

  13. Magnetizable stent-grafts enable endothelial cell capture

    Energy Technology Data Exchange (ETDEWEB)

    Tefft, Brandon J. [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Uthamaraj, Susheil [Division of Engineering, Mayo Clinic, Rochester, MN (United States); Harburn, J. Jonathan [School of Medicine, Pharmacy and Health, Durham University, Stockton-on-Tees (United Kingdom); Hlinomaz, Ota [Department of Cardioangiology, St. Anne' s University Hospital, Brno (Czech Republic); Lerman, Amir [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Dragomir-Daescu, Dan [Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN (United States); Sandhu, Gurpreet S., E-mail: sandhu.gurpreet@mayo.edu [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States)

    2017-04-01

    Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance. - Highlights: • Magnetic stent-grafts were made from 2205 steel stents and polyurethane nanofibers. • Stent-grafts remained patent and formed a thin and uniform neointima when implanted. • Stent-grafts captured endothelial cells labeled with magnetic nanoparticles.

  14. Octogenarian liver grafts: Is their use for transplant currently justified?

    Science.gov (United States)

    Jiménez-Romero, Carlos; Cambra, Felix; Caso, Oscar; Manrique, Alejandro; Calvo, Jorge; Marcacuzco, Alejandro; Rioja, Paula; Lora, David; Justo, Iago

    2017-05-07

    To analyse the impact of octogenarian donors in liver transplantation. We present a retrospective single-center study, performed between November 1996 and March 2015, that comprises a sample of 153 liver transplants. Recipients were divided into two groups according to liver donor age: recipients of donors ≤ 65 years (group A; n = 102), and recipients of donors ≥ 80 years (group B; n = 51). A comparative analysis between the groups was performed. Quantitative variables were expressed as mean values and SD, and qualitative variables as percentages. Differences in properties between qualitative variables were assessed by χ 2 test. Comparison of quantitative variables was made by t -test. Graft and patient survivals were estimated using the Kaplan-Meier method. One, 3 and 5-year overall patient survival was 87.3%, 84% and 75.2%, respectively, in recipients of younger grafts vs 88.2%, 84.1% and 66.4%, respectively, in recipients of octogenarian grafts ( P = 0.748). One, 3 and 5-year overall graft survival was 84.3%, 83.1% and 74.2%, respectively, in recipients of younger grafts vs 84.3%, 79.4% and 64.2%, respectively, in recipients of octogenarian grafts ( P = 0.524). After excluding the patients with hepatitis C virus cirrhosis (16 in group A and 10 in group B), the 1, 3 and 5-year patient ( P = 0.657) and graft ( P = 0.419) survivals were practically the same in both groups. Multivariate Cox regression analysis demonstrated that overall patient survival was adversely affected by cerebrovascular donor death, hepatocarcinoma, and recipient preoperative bilirubin, and overall graft survival was adversely influenced by cerebrovascular donor death, and recipient preoperative bilirubin. The standard criteria for utilization of octogenarian liver grafts are: normal gross appearance and consistency, normal or almost normal liver tests, hemodynamic stability with use of 30%.

  15. Synthesis of ion-exchange membranes by radiation-induced multiple grafting of methyl α,β,β-trifluoroacrylate

    International Nuclear Information System (INIS)

    Omichi, H.; Okamoto, J.

    1982-01-01

    Methyl α,β,β-trifluoroacrylate (MTFA) was grafted onto polymer films with the multiple grafting technique initiated by γ-rays: the yields were similar to those of the single-step grafting procedure with any irradiation dose. Grafted polymer obtained in the single-step experiments were distributed mainly near the film surface, whereas graft polymer from the multiple grafting experiments were distributed uniformly in the film at graft yields greater than 20%. The electric resistance of the hydrolyzed multiple graft polymer film in a 2N NaOH solution was much lower than that of one-step graft film at the same graft yield

  16. Nickel adsorption by sodium polyacrylate-grafted activated carbon

    International Nuclear Information System (INIS)

    Ewecharoen, A.; Thiravetyan, P.; Wendel, E.; Bertagnolli, H.

    2009-01-01

    A novel sodium polyacrylate grafted activated carbon was produced by using gamma radiation to increase the number of functional groups on the surface. After irradiation the capacity for nickel adsorption was studied and found to have increased from 44.1 to 55.7 mg g -1 . X-ray absorption spectroscopy showed that the adsorbed nickel on activated carbon and irradiation-grafted activated carbon was coordinated with 6 oxygen atoms at 2.04-2.06 A. It is proposed that this grafting technique could be applied to other adsorbents to increase the efficiency of metal adsorption.

  17. Influences of irradiation on the anastomotic sites of artificial graft

    International Nuclear Information System (INIS)

    Ogawa, Junichi; Inoue, Hiroshi; Koide, Shirosaku; Kawada, Shimei; Shotsu, Akira

    1989-01-01

    To examine the acute influences of irradiation on the anastomotic sites of EPTFE vascular grafts, experimental study was performed using canine dogs. After replacement of superior vena cava and bilateral femoral arteries with EPTFE grafts, a total of 20 to 100 Gy doses were given at the anastomotic sites of superior vena cava and right femoral artery. There were no degradation of grafts themselves or rupture in the anastomoses at cumulative anastomotic sites of superior vena cava, stenoses and/or overgrowth of granulation tissues were observed, although at those of right femoral artery, no remarkable differences were observed between dogs which received irradiation and those which did not receive. (author)

  18. Amino acids grafting of Ar+ ions modified PE

    International Nuclear Information System (INIS)

    Svorcik, V.; Hnatowicz, V.; Stopka, P.; Bacakova, L.; Heitz, J.; Oechsner, R.; Ryssel, H.

    2001-01-01

    Polyethylene (PE) was irradiated with 63 keV Ar + ions to the fluences from 1x10 12 to 3x10 15 cm -2 and then grafted at room temperature from water solution with amino acids (alanine, leucine). Using various spectroscopic techniques (UV-VIS, FTIR, RBS and EPR) it was shown that the amino acids penetrate into PE where they are eventually captured either on double bonds or on free radicals created by the ion irradiation. Grafting with amino acids in the whole specimen layer modified by irradiation is observed. The ion-beam-modified and amino-acid grafted PE is supposed to exhibit increased biocompatibility. (author)

  19. Kidney graft rejection studies with labeled platelets and lymphocytes

    International Nuclear Information System (INIS)

    Martin-Comin, J.

    1986-01-01

    The usefulness of In-111-labelled platelets and lymphocyte scintigraphy in acute kidney graft rejection is evaluated in 155 patients. Blood cells were labelled with 100-150 uCi of In-111-oxine and reinjected. Subsequently patients were scanned once daily from 2 hours post-reinjection up to a week. The graft/contralateral area activity ratio was calculated in all scans. It is concluded that In-111-labelled platelets scintigraphy is nowadays the method of choice for acute kidney graft rejection diagnosis, especially in patients under cyclosporine immunosuppression. (author)

  20. Importance of mesenchymal stem cells in autologous fat grafting

    DEFF Research Database (Denmark)

    Trojahn Kølle, Stig-Frederik; Oliveri, Roberto S; Glovinski, Peter Viktor

    2012-01-01

    the fat graft with adipose tissue-derived mesenchymal stem cells (ASC) before transplantation. We have reviewed original studies published on fat transplantation enriched with ASC. We found four murine and three human studies that investigated the subject after a sensitive search of publications....... In the human studies, so-called cell assisted lipotransfer (CAL) increased the ASC concentration 2-5 times compared with non-manipulated fat grafts, which caused a questionable improvement in survival of fat grafts, compared with that of traditional lipofilling. In contrast, in two of the murine studies ASC...

  1. Phthalate Migration Study from PVC Grafted by Gamma Radiation

    International Nuclear Information System (INIS)

    Manzoli, J.E.; Duarte, C.; Somesari, E.; Silveira, C.; Paes, H.A.; Manzoli, J.E.; Araujo, F.D.C.; Panzarini, L.C.G.A.

    2009-01-01

    PVC is a useful polymer used for many applications, as packaging of food, blood and in contact with body fluids. The most widely-used plasticizer, to make it flexible, is the phthalate DEHP, and its toxicity is a problem. A special radiation grafting of PVC allows an important reduction of thrombogenic properties, and it could cause changes in the DEHP migration too. In this work it is presented the methodology using gas chromatography and numerical simulation for the measurement of DEHP migration from PVC grafted with monomer DMAEMA. The grafting could be an interesting way to reduce DEHP migration

  2. Assessment of bone grafts placed within an oral and maxillofacial training programme for implant rehabilitation.

    Science.gov (United States)

    Kaing, L; Grubor, D; Chandu, A

    2011-12-01

    This study aimed to review the survival of bone grafting procedures, performed by surgical trainees and assess factors affecting survival of these bone grafts as an adjunct to implant rehabilitation. Data were collected from patients between 2003 and 2009 receiving bone grafting. Graft failure was defined as any complete or partial graft loss, graft which had to be removed or regrafted, or was unable to have an implant placed. Implant survival rates were not assessed in this study. Seventy-five patients received 86 bone grafts over a period of 7 years. Overall graft survival was 87.3% with 7 complete graft failures (8.1%) and 3 partial graft failures (4.6%). All failed grafts were of the block graft type, predominately in the anterior maxilla. The main reason for failure was secondary infection. Other complications occurred in about 27% of patients. Factors significantly increasing the risk of graft failure included use of bone block augmentation (p = 0.001), mixed autogenous/bone substitute grafts (p = 0.007) and diabetes mellitus (p = 0.006). Smoking was not found to affect graft survival. Good results were found in a series of patients treated in an oral and maxillofacial training programme. Care should be taken in regards to planning block grafts in diabetic patients. © 2011 Australian Dental Association.

  3. Hydrophilicity improvement of polyethersulfone membranes by grafting methacrylic acid with γ-ray irradiation

    International Nuclear Information System (INIS)

    Li Jing; Hou Zhengchi; Xie Leidong; Zhang Fengying; Deng Bo

    2005-01-01

    Grafting methyacrylic acid onto poly(ether sulfone) membranes was realized by means of simultaneous irradiation in liquids. The modified membranes with different grafting ratios were obtained by changing the concentration of methyacrylic acid. It was shown that the grafting ratio increased lineally as the monomer concentration was less than 10% and hydrophilicity of the membranes was improved with increasing grafting ratios. (authors)

  4. Breeding graft-compatible Douglas-fir rootstocks (Pseudotsuga menziesii (Mirb.) Franco).

    Science.gov (United States)

    D.L. Copes

    1999-01-01

    A study encompassing 24 years was conducted to determine if a breeding program could produce highly graft-compatible rootstocks. Twenty-seven trees of apparent high graft compatibility were selected and crossed to produce 226 control-pollinated families. Seedlings were grown, field planted, and grafted with test scions. Graft unions from field tests were evaluated...

  5. Bone formation in cranial, mandibular, tibial and iliac bone grafts in rats

    DEFF Research Database (Denmark)

    Solheim, E; Pinholt, E M; Talsnes, O

    1995-01-01

    Several studies have suggested that grafts from membranous derived bone (e.g., calvarial grafts) retain their volume better than those from endochondral derived bone (e.g., iliac bone grafts). Increased osteogenesis in grafts of the former type has been offered as the explanation. However, simple...

  6. Fluoropolymer-coated dacron versus PTFE grafts for femorofemoral crossover bypass: randomised trial

    DEFF Research Database (Denmark)

    Eiberg, J P; Røder, Ole Christian; Stahl-Madsen, Morten

    2006-01-01

    To investigate whether patency of a thin walled 8 mm fluoropassivated Dacron graft was similar to that of a standard 8mm PTFE graft for femorofemoral crossover bypass surgery.......To investigate whether patency of a thin walled 8 mm fluoropassivated Dacron graft was similar to that of a standard 8mm PTFE graft for femorofemoral crossover bypass surgery....

  7. Grafting of Bacterial Polyhydroxybutyrate (PHB) onto Cellulose via In Situ Reactive Extrusion with Dicumyl Peroxide

    Science.gov (United States)

    Liqing Wei; Armando G. McDonald; Nicole M. Stark

    2015-01-01

    Polyhydroxybutyrate (PHB) was grafted onto cellulose fiber by dicumyl peroxide (DCP) radical initiation via in situ reactive extrusion. The yield of the grafted (cellulose-g-PHB) copolymer was recorded and grafting efficiency was found to be dependent on the reaction time and DCP concentration. The grafting mechanism was investigated by electron spin...

  8. Quantitative Measurements of Competitive Flow in Left Internal Mammary Artery Bypass Grafts

    NARCIS (Netherlands)

    Spoor, Pien; Halfwerk, F.R.; Hagmeijer, Rob; Grandjean, J.G.

    2017-01-01

    OBJECTIVE: A low flow rate with diminished wall shear stress in arteries can cause intima hyperplasia and diameter reduction. In coronary artery bypass grafting (CABG) a low flow rate through the graft can cause graft failure (i.e. the string sign effect and occlusion). Arterial grafts bypassing an

  9. Comparative Proteomic Analysis of the Graft Unions in Hickory (Carya cathayensis Provides Insights into Response Mechanisms to Grafting Process

    Directory of Open Access Journals (Sweden)

    Daoliang Yan

    2017-04-01

    Full Text Available Hickory (Carya cathayensis, a tree with high nutritional and economic value, is widely cultivated in China. Grafting greatly reduces the juvenile phase length and makes the large scale cultivation of hickory possible. To reveal the response mechanisms of this species to grafting, we employed a proteomics-based approach to identify differentially expressed proteins in the graft unions during the grafting process. Our study identified 3723 proteins, of which 2518 were quantified. A total of 710 differentially expressed proteins (DEPs were quantified and these were involved in various molecular functional and biological processes. Among these DEPs, 341 were up-regulated and 369 were down-regulated at 7 days after grafting compared with the control. Four auxin-related proteins were down-regulated, which was in agreement with the transcription levels of their encoding genes. The Kyoto Encyclopedia of Genes and Genomes (KEGG analysis showed that the ‘Flavonoid biosynthesis’ pathway and ‘starch and sucrose metabolism’ were both significantly up-regulated. Interestingly, five flavonoid biosynthesis-related proteins, a flavanone 3-hyfroxylase, a cinnamate 4-hydroxylase, a dihydroflavonol-4-reductase, a chalcone synthase, and a chalcone isomerase, were significantly up-regulated. Further experiments verified a significant increase in the total flavonoid contents in scions, which suggests that graft union formation may activate flavonoid biosynthesis to increase the content of a series of downstream secondary metabolites. This comprehensive analysis provides fundamental information on the candidate proteins and secondary metabolism pathways involved in the grafting process for hickory.

  10. Experimental Comparison of Cranial Particulate Bone Graft, rhBMP-2, and Split Cranial Bone Graft for Inlay Cranioplasty.

    Science.gov (United States)

    Hassanein, Aladdin H; Couto, Rafael A; Kurek, Kyle C; Rogers, Gary F; Mulliken, John B; Greene, Arin K

    2013-05-01

    Background :  Particulate bone graft and recombinant human bone morphogenetic protein-2 (rhBMP-2) are options for inlay cranioplasty in children who have not developed a diploic space. The purpose of this study was to determine whether particulate bone graft or rhBMP-2 has superior efficacy for inlay cranioplasty and to compare these substances to split cranial bone. Methods :  A 17 mm × 17 mm critical-sized defect was made in the parietal bones of 22 rabbits and managed in four ways: Group I (no implant; n=5), Group II (particulate bone graft; n=5), Group III (rhBMP-2; n=7), and Group IV (split cranial bone graft; n=5). Animals underwent microcomputed tomography and histologic analysis 16 weeks after cranioplasty. Results :  Defects without an implant (Group I) demonstrated inferior ossification (41.4%; interquartile range [IQR], 28.9% to 42.5%) compared to those treated with particulate bone graft (Group II: 99.5%; IQR, 97.8% to 100%), rhBMP-2 (Group III: 99.6%; IQR, 99.5% to 100%), or split cranial bone (Group IV: 100%) (P inlay calvarial defect areas equally, although the thickness of bone healed with rhBMP-2 is inferior. Clinically, particulate bone graft or split cranial bone graft may be superior to rhBMP-2 for inlay cranioplasty.

  11. Os acromiale open reduction and internal fixation: a review of iliac crest autogenous bone grafting and local bone grafting.

    Science.gov (United States)

    Atinga, Mordicai; Gregor, Reinhold; Selvaraj, Karthik M; Hong, Thin F

    2018-01-17

    Symptomatic os acromiale are fairly uncommon, and treatment has included fragment excision, decompression, and open reduction and internal fixation. Nonunion rates as high as 40% have been reported after fixation of os acromiale. This study assessed whether union of an os acromiale could be reliably achieved without the use of an iliac crest bone graft. This was a retrospective study of 32 consecutive shoulders that were treated with screw fixation and a local bone graft or iliac crest bone graft. The mean age was 50.3 years (range, 21-74 years), and the mean follow-up was 46.9 months (range, 12-120 months). Fusion was assessed clinically and radiologically. All 32 os acromiale were fused by 3 months on x-ray imaging. There were 18 shoulders in the iliac crest bone graft group and 14 in the local bone graft group. Rotator cuff repairs were performed concomitantly in 25 patients. Hardware was removed in 4 patients, a seroma was drained in 1 patient, and a superficial infection occurred in 1 patient. This is the largest study of os acromiale fixation using screws and a tension band to our knowledge. We report a 100% union rate using this technique, with 13% requiring hardware removal and the occurrence of 1 superficial infection. This study shows a local bone graft is as effective as iliac crest bone graft in achieving fusion. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  12. RELATIONSHIPS BETWEEN GRAFT SUCCESS AND CLIMATIC VALUES IN WALNUT (JUGLANS REGIA L.

    Directory of Open Access Journals (Sweden)

    T Karadeniz

    2006-07-01

    Full Text Available The study determines the graft take of walnut in Ordu province located in the East Black Sea Region. Grafting studies were carried out in nursery conditions in late August from 1993 to 2000. During these years, a total of 87 264 applied grafts were evaluated by using patch-grafting method. The graft take varied from 29% to 64 % depending on years. Relations between the graft take and climate conditions were also considered. Graft take under nursery conditions was affected by especially relative moisture (% in addition to the mean and maximum temperature (°C in August and September months.

  13. Renal vessel reconstruction in kidney transplantation using a polytetrafluoroethylene (PTFE) vascular graft.

    Science.gov (United States)

    Kamel, Mohamed H; Thomas, Anil A; Mohan, Ponnusamy; Hickey, David P

    2007-04-01

    We report a rare experience in reconstructing short renal vessels in kidney transplantation using polytetrafluroethylene (PTFE) vascular grafts. The short renal vessels in three kidney grafts were managed by the interposition of PTFE vascular grafts. Two grafts were from deceased donors and the third was a renal auto-transplant graft. PTFE grafts were used to lengthen short renal veins in two kidney grafts and a short renal artery in one. The warm ischaemia time was under 1 h and all kidneys functioned well post-operatively. Excellent blood perfusion in the three renal grafts was present on postoperative MAG 3 renal scan. No intra-operative or post-operative complications were encountered. In the three described patients, the use of PTFE vascular graft presented no additional morbidity to the kidney transplant operation and no post-oerative complication was related to its use. However, more data are necessary to conclude that PTFE graft can be used safely in kidney transplantation.

  14. Modification of polyetherurethane for biomedical application by radiation induced grafting. II. Water sorption, surface properties, and protein adsorption of grafted films

    International Nuclear Information System (INIS)

    Jansen, B.; Ellinghorst, G.

    1984-01-01

    A series of polyetherurethane films grafted by means of gamma radiation with hydrophilic or reactive monomers (2-hydroxyethyl methacrylate, 2,3-epoxypropyl methacrylate, 2,3-dihydroxypropyl methacrylate, and acrylamide) and partially chemically modified were subjected to various physico-chemical investigation methods involving water sorption, contact angle, and protein adsorption measurements. From contact angle data the interfacial free energy gamma sw between grafted films and water was calculated. It was found that the water uptake of grafted films increases with grafting yield or, in the case of grafted and afterwards chemically modified films, with reaction yield; the diffusion coefficient of water in the modified films also increases with grafting yield. Contact angle studies revealed all grafted films to have surfaces more hydrophilic than the ungrafted trunk polymer. The degree of hydrophilicity--especially of HEMA-grafted films--strongly depends on grafting conditions. For some grafted samples with high surface hydrophilicity very low interfacial free energies approaching zero were measured. The study of the competitive adsorption of bovine serum albumin, gamma-globulin, and fibrinogen from a synthetic protein solution onto modified films showed that the adsorption of albumin increases markedly with increasing grafting yields, whereas the fibrinogen and gamma-globulin adsorption only slightly increases. A correlation between interfacial free energy and protein adsorption in the sense of the minimum interfacial free energy hypothesis was found only for samples with grafting yields below 5%. At higher grafting yields the increased surface area complicates the analysis

  15. New membranes obtained by grafted irradiated PVDF foils

    Energy Technology Data Exchange (ETDEWEB)

    Mazzei, R. [Unidad de Actividades Tecnologicas y Agropecuarias, Laboratorio de Polimeros, Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Universidad Tecnologica Nacional Facultad Regional, Buenos Aires (Argentina); Garcia Bermudez, G. [Gerencia de Investigacion y Aplicaciones, Laboratorio Tandar, Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Escuela de Ciencia y Tecnologia, Universidad Nacional de General San Martin, Buenos Aires (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas, Buenos Aires (Argentina); Camporotondi, D.E., E-mail: camporotondi@cae.cnea.gov.ar [Unidad de Actividades Tecnologicas y Agropecuarias, Laboratorio de Polimeros, Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Arbeitman, C. [Gerencia de Investigacion y Aplicaciones, Laboratorio Tandar, Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas, Buenos Aires (Argentina); and others

    2012-09-15

    The present work describes a new method to produce membranes of poly(Acrylic-acid-Xmonomer) using the grafting procedure. PVDF foils irradiated with Ar{sup +} beam with energies between 30 and 150 keV were employed as substratum. Different combinations of monomers in water solutions were used: acrylic acid (AAc); acrylic acid-glycidyl methacrylate (AAc-GMA); acrylic acid-styrene (AAc-S), acrylic acid-N-isopropyl acrylamide (AAc-NIPAAm) and acrylic acid-N-isopropyl acrylamide-glycidyl methacrylate (AAc-NIPAAm-GMA). A large percentage of grafting results for specific values of: ion fluence and energy, AAc and sulfuric acid concentration, and different substrata PVDF polymorphous (alpha or beta). At a particular time of the grafting process, the poly(AAc-Xmonomer) membranes detach from the substratum and continue their grafting in the solution. This method is useful to produce increased replicated membranes of the irradiated original surface.

  16. The graft copolymerisation of acrylamide onto cellulose using ...

    African Journals Online (AJOL)

    Theobroma cacao) wood meal have been produced using hydroquinone enhanced Fe2+/H2O2 redox system. The addition of hydroquinone to the redox system affected the effectiveness of the redox system to initiate graft copolymer formation.

  17. Effect of maxillary sinus floor augmentation without bone grafts

    Directory of Open Access Journals (Sweden)

    D Shiva Kumar

    2013-01-01

    Full Text Available Objective: The objective of the present review was to determine the effectiveness of maxillary sinus floor augmentation without bone grafts using lateral window technique. Materials and Methods: PubMed and Cochrane databases were searched for relevant articles. We also included articles by hand search until June 2012. The analysis included both human and animal studies which satisfied the following criteria: Minimum of 6 months follow-up, no use of bone grafts, and lateral window approach to the sinus. Results: We included 22 articles in the review. A descriptive analysis of the constructed evidence tables indicated that there is evidence of predictable a mount of bone formation in the maxillary sinus augmentation without the use of bone grafts. Conclusion: Within the limits of the articles and data available, maxillary sinus augmentation without bone graft might be considered effective inpredictable bone formation.

  18. Grafting study of polysulfone polymeric membranes by gamma ray irradiation

    International Nuclear Information System (INIS)

    Furtado Filho, Acacio A.M.; Gomes, Ailton de S.

    2011-01-01

    Radiation-induced grafting of styrene poli sulfone films were investigated by simultaneous method in solution using gamma-ray from a radio nuclide 60 Co source. The gamma-ray energy of high intensity induced breaking of chemical bonds leading to free radical formation. The radical start a conventional polymerization sequence comparable with that obtained with a chemical catalyst acting as initiator. The effects of grafting conditions such as irradiation total dose, dose rate and addition of cross linking agent, were studied by means of morphology analysis, thermal degradation and crystallinity. After the grafting reaction, the membranes were submitted to an exhaustive extraction with solvent to remove the polystyrene homopolymer formed. The degree of grafting (DOG) was analyzed by percentage of weight increase. As a result, the reaction always follows the same pattern: DOG increases rapidly initially whilst propagation is the main reaction, then more slowly as termination becomes more frequent. (author)

  19. Causes of limited survival of microencapsulated pancreatic islet grafts

    NARCIS (Netherlands)

    de Groot, Martijn; Schuurs, T.A; van Schilfgaarde, Reinout

    Successful transplantation of pancreatic tissue has been demonstrated to be an efficacious method of restoring glycemic control in type 1 diabetic patients. To establish graft acceptance patients require lifelong immunosuppression, which in turn is associated with severe deleterious side effects.

  20. Bone grafting simultaneous to implant placement. Presentation of a case.

    Science.gov (United States)

    Peñarrocha-Diago, Miguel; Gómez-Adrián, Maria Dolores; García-Mira, Berta; Ivorra-Sais, Mariola

    2005-01-01

    Bone defects at mandibular alveolar crest level complicate the placement of dental implants in the ideal location. Surgical reconstruction using autologous bone grafts allows implant fixation in an esthetic and functional manner. We describe a patient with large mandibular bone loss secondary to periodontal inflammatory processes. Reconstruction of the mandibular alveolar process was carried out using onlay block bone grafts harvested from the mandible. The grafts were stabilized by positioning the dental implants through them--a procedure that moreover afforded good primary implant fixation. After two years of follow-up the clinical and radiological outcome is good. In the lower jaw, where bone regeneration is complicated, we were able to achieve good results in this patient--minimizing the corresponding waiting time by grafting and placing the implants in the same surgical step.

  1. Tectonic corneal graft for conjunctival rhinosporidiosis with scleral melt

    Directory of Open Access Journals (Sweden)

    Pushpa Jacob

    2011-01-01

    Full Text Available A 16 year old girl presented with irritation and watering of the right eye for 3 months. On examination, the superior perilimbal sclera was ectatic with incarcerated uveal tissue covered by conjunctiva. The conjunctiva showed discreet, yellow white mucoid spots. Excision biopsy of the conjunctiva showed subepithelial spherules of sporangia containing numerous endospores, suggestive of rhinosporidiosis. Diathermy was applied to flatten the staphyloma. The ectatic area was covered with a corneal patch graft. The patient was started on prednisolone acetate eye drops and oral dapsone for 6 months. Corneal graft was well incorporated and conjunctivalized by 3 months. Since the graft was not seen within the palpebral aperture, there was good cosmetic result. The corneal graft had the added advantage of transparency which allowed visualization of the underlying tissue to diagnose early recurrence. There was no recurrence at 6 months.

  2. Electroosmotic Flow in Mixed Polymer Brush-Grafted Nanochannels

    Directory of Open Access Journals (Sweden)

    Qianqian Cao

    2016-12-01

    Full Text Available Mixed polymer brush-grafted nanochannels—where two distinct species of polymers are alternately grafted on the inner surface of nanochannels—are an interesting class of nanostructured hybrid materials. By using a coarse-grained molecular dynamics simulation method, we are able to simulate the electrokinetic transport dynamics of the fluid in such nanochannels as well as the conformational behaviors of the mixed polymer brush. We find that (1 the brush adopts vertically-layered and longitudinally-separated structures due to the coupling of electroosmotic flow (EOF and applied electric field; (2 the solvent quality affects the brush conformations and the transport properties of the EOF; (3 the EOF flux non-monotonically depends on the grafting density, although the EOF velocity in the central region of the channel monotonically depends on the grafting density.

  3. Ibrutinib Effective against Graft-Versus-Host Disease

    Science.gov (United States)

    A Cancer Currents blog post on results from a small clinical trial showing that ibrutinib can effectively treat graft-versus-host-disease, a common and serious complication of allogeneic stem cell transplants.

  4. Computerized tomographic evaluation of aortic prosthetic graft complications

    International Nuclear Information System (INIS)

    Kay, D.; Kalmar, J.A.

    1985-01-01

    Computerized tomography has been found to be an accurate and sensitive method of diagnosing complications of synthetic aortic grafts. Complications in this series of four cases included aortoesophageal fistula, aortoduodenal fistula, pseudoaneurysm, and retroperitoneal hematoma. 6 references, 5 figures

  5. Alveolar cleft closure with iliac bone graft: A case report.

    Directory of Open Access Journals (Sweden)

    Tichvy Tammama

    2017-04-01

    Conclusion: The timing of alveolar bone grafting usually associated with the state of the developing of dentition. Post operative management is important to get a good result, and to prevent any complications.

  6. Role of complement in graft rejection after organ transplantation

    NARCIS (Netherlands)

    Bos, Ineke G. A.; ten Berge, Ineke J. M.; Hack, C. Erik

    2002-01-01

    Activation of the complement system may significantly contribute to the inflammatory reaction after solid organ transplantation. In allotransplantation, the complement system may be activated by ischemia/reperfusion and, possibly, by antibodies directed against the graft. In xenotransplantation from

  7. Antiplatelet therapy at the time of coronary artery bypass grafting

    DEFF Research Database (Denmark)

    Kremke, Michael; Tang, Mariann; Bak, Mikkel

    2013-01-01

    OBJECTIVES: The purpose of this multicentre cohort study was to examine the relationship between antiplatelet therapy (APT) at the time of coronary artery bypass grafting (CABG) and postoperative bleeding complications, transfusion requirements and adverse cardiovascular events. METHODS: A matche...

  8. Fundamental Investigations Regarding Barrier Properties of Grafted PVOH Layers

    Directory of Open Access Journals (Sweden)

    Markus Schmid

    2012-01-01

    Full Text Available The current work focuses on fundamental investigations regarding the barrier properties of grafted PVOH layers produced by the Transfer Method. The layers (or papers used for the different experiments were produced and grafted during the course of this work. Papers with different types of PVOH (different Mowiol types were produced by coating. Experiments using different parameters (temperature, reaction duration, and concentration were performed using the Transfer Method. Contact angle measurements and Cobb60 measurements were carried out on the grafted and untreated PVOH layers. Furthermore, the water vapour transmission rate of the PVOH layers was determined. The results of this work showed that the method of chromatogeny or chromatogenic chemistry improves the water vapour barrier properties of grafted PVOH layers enormously.

  9. Comparison of cartilage graft and fascia in type 1 tympanoplasty: systematic review and meta-analysis.

    Science.gov (United States)

    Yang, Tao; Wu, Xuewen; Peng, Xiaofei; Zhang, Yanni; Xie, Shaobing; Sun, Hong

    2016-11-01

    Tympanoplasty using cartilage grafts has a better graft take rate than that using temporalis fascia grafts. There are no significant differences between cartilage grafts and temporalis fascia grafts for hearing outcomes. Contrary to the sliced cartilage sub-group, full-thickness cartilage grafts generate better hearing outcomes than temporalis fascia grafts. Tympanic membrane perforation can cause middle ear relapsing infection and lead to hearing damage. Various techniques have been applied in order to reconstruct the tympanic membrane. Recently, cartilage grafts and temporalis fascia grafts have been widely used for tympanic membrane closure. A systemic review and meta-analysis was carried out based on published retrospective trials that investigated the efficacy of cartilage grafts and temporalis fascia grafts in type 1 tympanoplasty. Both graft take rates and mean AIR-BONE-GAP gains were analyzed. Cochrane Library, PubMed, and Embase were systematically searched. After a scientific investigation, we extracted the relevant data following our selection criteria. Odds ratio (OR) of graft take rates and mean difference (MD) of AIR-BONE-GAP gains were calculated within 95% confidence intervals. Eight eligible articles with 915 patients were reviewed. The pooled OR for graft take rate was 3.11 (95% CI =1.94-5.00; p = 0.43) and the difference between the two groups was significant, which means that the cartilage grafts group got a better graft take rate than the temporalis fascia grafts group. The pooled MD for mean AIR-BONE-GAP gain was 1.92 (95% CI = -0.12-3.95; p fascia grafts group. On the contrary, the pooled MD of sliced cartilage grafts sub-group was 0.12 (95% CI = -0.44-0.69; p = 0.61) and there was no significant difference between the sliced cartilage grafts and temporalis fascia group.

  10. Multiquadrant Subtenon Triamcinolone Injection for Acute Corneal Graft Rejection: A Case Report

    Directory of Open Access Journals (Sweden)

    Sunali Goyal

    2017-05-01

    Full Text Available Background: We report a case of reversal of an acute corneal graft rejection following multiquadrant subtenon triamcinolone injection. Case Presentation: A 19-year-old woman who had acute corneal graft rejection failed to show resolution of the graft rejection after standard treatment with systemic, intravenous, and topical steroids. The graft rejection, however, responded to injection of triamcinolone in multiple subtenon quadrants. Conclusions: For corneal graft rejection, multiquadrant subtenon triamcinolone injections may be a safe adjunct to systemic treatment.

  11. Does graft mass impact on pediatric kidney transplant outcomes?

    Science.gov (United States)

    Feltran, Luciana de Santis; Nogueira, Paulo Cesar Koch; Ajzen, Sergio Aron; Verrastro, Carlos Gustavo Yuji; Pacheco-Silva, Alvaro

    2014-02-01

    The aim of this study is to assess the evolution of renal size and function in pediatric transplant patients according to the graft mass/recipient size ratio. Fifty pediatric renal transplant recipients were followed over 2 years. Grafts were weighed, and three different graft mass/m(2) ratios were determined: (1) low graft mass (58 g/m(2), range 31-57 g/m(2)), (2) median (142 g/m(2), range 59-141 g/m(2)) and high (267 g/m(2), range 143-353 g/m(2)). Patients underwent repeated ultrasound Doppler scans and repeated measurements of estimated glomerular filtration rate (eGFR; 1 week and 1, 6, 12 and 24 months), urinary retinol-binding protein (RBP) and proteinuria (1 week and 6, 12 and 24 months). The volume of renal tissue increased by 12 ± 5.6 cm(3) at 24 months (p = 0.035) in the low graft mass and decreased by -14 ± 7 cm(3) (p = 0.046) in the high graft mass. The eGFR increased when either low (30 ± 5 ml/min/1.73 m(2), p < 0.001) or median (19 ± 4 ml/min/1.73 m(2), p < 0.001) graft mass was transplanted but remained stable when high graft mass was transplanted. The resistive index (RI) presented a significant decrease throughout early follow-up in the transplants involving low and median graft mass, whereas a slight rise was observed in those involving high graft mass. A significant difference was apparent 6 months post-transplant. Transplants of low and median graft mass were associated with an initial higher urinary RBP. No significant differences in proteinuria were detected. Small kidneys undergo increases in volume and function without escalation of either proteinuria or urinary RBP, characterizing an adequate adaptation to the recipient. Children receiving larger kidneys present a reduction in volume, stable GFR and higher RI at 6 months.

  12. Rivaroxaban for the treatment of saphenous vein graft thrombosis.

    Science.gov (United States)

    Marmagkiolis, Konstantinos; Cilingiroglu, Mehmet

    2016-01-01

    Thrombus formafigtion plays a significant role in disease of saphenous vein bypass grafts. Use of oral anticoagulants has not been tested in treatment of thrombotic occlusion of saphenous vein graft (SVG) disease. Here we describe the use of the novel oral anticoagulant rivaroxaban in the treatment of occlusive SVG disease with intraluminal thrombus, leading to successful recanalization. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Neointima development in externally stented saphenous vein grafts

    Directory of Open Access Journals (Sweden)

    Przemysław Węglarz

    2016-11-01

    Full Text Available Introduction : The main limitation of coronary artery bypass grafting (CABG is rapid neointimal hyperplasia leading to graft failure. Aim : To assess plaque formation in saphenous vein grafts (SVG covered by an external Dacron stent in comparison with the classical technique. Material and methods : In the study group vein grafts covered by external stent mesh made of Dacron were implanted. An intravascular ultrasonography (IVUS study was performed in 35 aorto-coronary SVG covered by an external Dacron stent and in 64 normal SVG during the first year after CABG. In each SVG 25 mm of good quality IVUS image, volumes of lumen, plaque (neointima, outer border of the vein graft (external SVG and adventitia were calculated in three time periods: 0–130 days, 130–260 days and 260–390 days. Results : Between the first and second time period, lumen volume (mm3 was reduced from 10.33 ±4.4, to 6.80 ±2.23 in the second period and 5.69 ±1.26 in the third one. This effect was much less marked in normal grafts. The corresponding lumen volume (mm3 was: 10.90 ±3.9, 9.15 ±2.94 and 8.92 ±2.93 in consecutive time periods. Plaque volume (mm3 did not change in control grafts during the course of the study, but it increased very significantly in stented grafts from 0.86 ±1.24 in the first period to 2.70 ±1.58 in the second and 3.29 ±2.66 in the third one. Conclusions : The experimental technique of implanting SVG covered with an external elastic Dacron stent seems to be inferior to traditional ones. This is probably due to the more complicated process of vein implantation and higher micro-injury occurrence during the surgery.

  14. Polymer-stabilized gold nanoparticles with high grafting densities.

    Science.gov (United States)

    Corbierre, Muriel K; Cameron, Neil S; Lennox, R Bruce

    2004-03-30

    A series of polymer-coated Au nanoparticles have been prepared using the "grafting-to" approach. Thiol-terminated polystyrene and poly(ethylene oxide) ligands are found to form dense brushes on the faceted gold nanoparticle surfaces. Depending on the polymer, the ligand grafting densities on the gold nanoparticles are 1.2- to 23.5-fold greater than those available via self-assembled monolayer formation of the corresponding two-dimensional gold surfaces.

  15. Flexible particle array structures by controlling polymer graft architecture.

    Science.gov (United States)

    Choi, Jihoon; Dong, Hongchen; Matyjaszewski, Krzysztof; Bockstaller, Michael R

    2010-09-15

    Surface-initiated atom-transfer radical polymerization is used to synthesize particle brushes with controlled fraction of extended and relaxed conformations of surface-grafted chains. In the semidilute brush limit, the grafting of polymeric ligands is shown to facilitate the formation of ordered yet plastic-compliant particle array structures in which chain entanglements give rise to fracture through a polymer-like crazing process that dramatically increases the toughness and flexibility of the particle assembly.

  16. Grafting guava on cattley guava resistant to Meloidogyne enterolobii

    OpenAIRE

    Robaina,Renata Rodrigues; Campos,Graziella Siqueira; Marinho,Cláudia Sales; Souza,Ricardo Moreira; Bremenkamp,Cíntia Aparecida

    2015-01-01

    The use of resistant rootstocks could be a promising method to control nematodeMeloidogyne enterolobiiin commercial plantations of guava. The present study aimed to evaluate the success of grafting guava as a scion on accessions of cattley guava as rootstocks resistant to M. enterolobii.The treatments consisted of the rootstocks cattley guava plants (three accessions of Psidium cattleyanum) and common guava (control). In the apical wedge grafting method, scion of Paluma cultivated variety was...

  17. Protective effect of dexmedetomidine in coronary artery bypass grafting surgery

    OpenAIRE

    REN, JIANJUN; ZHANG, HUIJUN; HUANG, LINING; LIU, YUE; LIU, FENGQIN; DONG, ZHENMING

    2013-01-01

    The aim of this study was to observe the impact of dexmedetomidine on postoperative myocardial injury in patients undergoing off-pump coronary artery bypass (OPCAB) grafting. One hundred and sixty-two patients who were undergoing OPCAB surgery were randomly divided into control and dexmedetomidine groups (groups C and Dex, respectively). Following the first vascular anastomosis grafting, the patients in group Dex received a continuous intravenous infusion of 0.2?0.5 ?g/kg/h dexmedetomidine, u...

  18. Graft position and fusion rate following arthroscopic Latarjet.

    Science.gov (United States)

    Casabianca, Laurent; Gerometta, Antoine; Massein, Audrey; Khiami, Frederic; Rousseau, Romain; Hardy, Alexandre; Pascal-Moussellard, Hugues; Loriaut, Philippe

    2016-02-01

    The arthroscopic Latarjet procedure is recently becoming an increasingly popular technique. Nevertheless, position and fusion of the autograft had not been well studied yet. The purpose of this study was to assess the positioning of the coracoid graft and the fusion rate on CT scan in the arthroscopic Latarjet procedure. The study design was a prospective series of 19 consecutive patients who received arthroscopic Latarjet procedure. Radiological assessment on CT scan performed 3 months post-operatively included an analysis of the fusion and the position of the coracoid bone graft using a validated method. 02:30-04:20 was considered an ideal positioning in the sagittal view. In the axial view, the positioning was considered as flush, congruent, medial, too medial, or lateral. The median age of patients was 27.6 (±6.9). Mean operative time was of 161 min ±34.8. The fusion rate was of 78 %. Coracoid grafts were positioned 01:52 h (56° ± 14°) to 4:04 h (122° ± 12.5°). In the axial view, 32 % of the grafts positioning were considered as flush, 38 % as congruent, 30 % as medial, and 6 % too medial. No lateral position was noted. Two complications occurred, one graft fracture during screwing requiring opening conversion and an early case of osteolysis in a medial-positioned graft. The arthroscopic Latarjet procedure is a technically challenging technique that provides satisfactory fusion rate and graft positioning with a low complication rate. The clinical importance of this study lies in the observation that it is the first study to evaluate the position of the coracoid bone graft in arthroscopic Latarjet according to a detailed and validated method. IV.

  19. Application of Biological Tissue Grafts for Burns in Zambia

    International Nuclear Information System (INIS)

    Chishimba, Gershom

    2001-01-01

    The author discusses the advances made in the use of Biological Tissue Grafts for the treatment of burns.The paper outlines research activities and clinical trials done in the use of gamma radiation sterilised Amnion membranes and Pig skin grafts in the zambian Heath Care System for treatment of Burns.Ethical issues of Tissue Banking are also discussed in relation to religious and cultural beliefs and Good Manufacturing Practices

  20. Recipient Wound Bed Characteristics Affect Scarring and Skin Graft Contraction

    Science.gov (United States)

    2015-02-13

    presence of myofibroblasts and leukocytic infiltration. Injuries resulting in loss of dermal coverage are typically treated by means of eschar excision or...hypodermis is usually dictated by the severity of injury and may not always be possible, restoration of the hypodermis through tissue engineering, before or...in leukocyte infiltra- tion between grafts on fat and grafts on fascia by staining for CD45, the leukocyte common antigen ( LCA ) (Figure 6). Although

  1. Post-irradiation grafting of tetrafluoroethylene at low temperatures

    International Nuclear Information System (INIS)

    Barkalov, I.M.; Kiryukhin, D.P.; Muydinov, M.R.

    1981-01-01

    Low-temperature postirradiation grafting of tetrafluoroethylene (TFE) to polyolefines and silicone elastomers was the subject of study. After preliminary dissolution of TFE in the polymer at 273 0 K the system was slowly cooled to 77 0 K. In this process a certain part of TFE in polyolefines (ethylene-propylene copolymer and polypropylene) is retained by the vitreous polymer matrix. When slowly heated after radiolysis at 77 0 K this system shows graft polymerization of dissolved TFE after T/sub g/. The graft copolymer is soluble and its IR spectra contain absorption bands characteristic of polytetrafluoroethylene. In polydimethylsiloxane rubber (SKT) the dissolved TFE when frozen to 77 0 K remains sorbed between the SKT crystallites rather than in a separate phase. When those radiolyzed samples are heated the graft-polymerization occurs primarily over the temperature range between the TFE and SKT melting points. The technique provides for 100 to 150% grafting of TFE. This method also permits grafting to silicone rubbers and to several other polymers and elastomers

  2. Grafting of gold nanoparticles on polyethyleneterephthalate using dithiol interlayer

    International Nuclear Information System (INIS)

    Reznickova, A.; Kolska, Z.; Zaruba, K.; Svorcik, V.

    2014-01-01

    Two different procedures of grafting of polyethyleneterephthalate (PET), modified by plasma treatment, with gold nanoparticles (nanospheres) are studied. In the first procedure the PET foil was grafted with biphenyl-4,4′-dithiol and subsequently with gold nanoparticles. In the second one the PET foil was grafted with gold nanoparticles previously coated by the same dithiol. X-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy and electrokinetic analysis were used for characterization of the polymer surface at different modification steps. Gold nanoparticles were characterized by ultraviolet–visible spectroscopy. The first procedure was found to be more effective. It was proved that the dithiol was chemically bonded to the surface of the plasma activated PET and it mediates subsequent grafting of the gold nanoparticles. - Highlights: • Two different techniques were used for coating of PET with gold nanoparticles. • Grafted GNPs were characterized by XPS, FTIR, UV–vis, zeta potential, AFM. • More effective coating is achieved by deposition of GNPs earlier grafted with thiol. • The studied structures may have potential application in electronics or biomedicine

  3. Photoinitiator grafted styrene-butadiene-styrene triblock copolymer

    International Nuclear Information System (INIS)

    Wu Guoliang; Zeng Songjun; Ou Encai; Yu Puren; Lu Yanbing; Xu Weijian

    2010-01-01

    Grafting of photoinitiator-4-maleimidobenzophenone (4-MBP) onto styrene-butadiene-styrene (SBS) triblock copolymer was carried out by free radical polymerization. The grafting ratio was evaluated by varying initiator concentrations, and the structure of grafted copolymer (SBS-g-MBP) was characterized by attenuated total reflectance infrared Fourier transform spectroscopy (ATR-FTIR), proton nuclear magnetic resonance ( 1 H NMR) and X-ray photoelectron spectroscopy (XPS). The results confirmed that 4-MBP was successfully grafted onto the SBS backbone. Thermal gravimetric analyzer (TGA), dynamic mechanical thermal analysis (DMTA), scanning electron microscopy (SEM), and atomic force microscopy (AFM) were used to study the thermal properties and morphology of the SBS-g-MBP. From the data of TGA, the SBS-g-MBP had better thermal stability compared with that of SBS. DMTA testing indicated that the glass transition temperature (T g ) of SBS-g-MBP was higher than that of SBS. With the aid of SEM and AFM, the structure of micro-phase separation can be observed obviously. What is more, the aggregates become smaller compared with those of pure SBS. The experiment of UV-crosslinked SBS-g-MBP revealed that the gel fraction could be facilely controlled by adjusting grafting ratio and exposure time. The results suggested that this novel grafted copolymer could be attractive for its application in biomedical materials such as medical pressure-sensitive adhesive.

  4. The Impact of Liver Graft Injury on Cancer Recurrence Posttransplantation.

    Science.gov (United States)

    Li, Chang-Xian; Man, Kwan; Lo, Chung-Mau

    2017-11-01

    Liver transplantation is the most effective treatment for selected patients with hepatocellular carcinoma. However, cancer recurrence, posttransplantation, remains to be the critical issue that affects the long-term outcome of hepatocellular carcinoma recipients. In addition to tumor biology itself, increasing evidence demonstrates that acute-phase liver graft injury is a result of hepatic ischemia reperfusion injury (which is an inevitable consequence during liver transplantation) and may promote cancer recurrence at late phase posttransplantation. The liver grafts from living donors, donors after cardiac death, and steatotic donors have been considered as promising sources of organs for liver transplantation and are associated with high incidence of liver graft injury. The acute-phase liver graft injury will trigger a series of inflammatory cascades, which may not only activate the cell signaling pathways regulating the tumor cell invasion and migration but also mobilize the circulating progenitor and immune cells to facilitate tumor recurrence and metastasis. The injured liver graft may also provide the favorable microenvironment for tumor cell growth, migration, and invasion through the disturbance of microcirculatory barrier function, induction of hypoxia and angiogenesis. This review aims to summarize the latest findings about the role and mechanisms of liver graft injury resulted from hepatic ischemia reperfusion injury on tumor recurrence posttransplantation, both in clinical and animal cohorts.

  5. Scarless abdominal fat graft harvest for neurosurgical procedures: technical note.

    Science.gov (United States)

    Trinh, Victoria T; Duckworth, Edward A M

    2015-02-01

    Background Abdominal fat grafts are often harvested for use in skull base reconstruction and cerebrospinal fluid (CSF) leak repairs, and for operations traversing the nasal sinuses or mastoid bone. Although the endoscopic transnasal surgery has gained significant popularity, in part because it is considered "scarless," a common adjunct, the abdominal fat graft, can result in a disfiguring scar across the abdomen. Objective This is the first report of a scarless abdominal fat graft technique for skull base reconstruction. Methods Ten patients with a median age of 56.5 years (range: 45-73 years) underwent endoscopic transsphenoidal tumor resection with intraumbilical fat graft harvest. Careful circumferential fat dissection at the umbilicus, with progressive retraction of the graft, was crucial to ensure maximal visualization and to prevent injury to the subcutaneous vessels and rectus fascia. Results Following reconstruction of the sellar skull base, all patients did well postoperatively with no evidence of CSF leak. At 12-week follow-up for all patients, there was no evidence of scar, intracavity hematoma, or wound infection. Conclusions Fat graft harvest through an intraumbilical incision results in a scar-free abdominal harvest, and is a useful procedural adjunct to complement "scarless" brain surgery.

  6. Toward a patient-specific tissue engineered vascular graft.

    Science.gov (United States)

    Best, Cameron; Strouse, Robert; Hor, Kan; Pepper, Victoria; Tipton, Amy; Kelly, John; Shinoka, Toshiharu; Breuer, Christopher

    2018-01-01

    Integrating three-dimensional printing with the creation of tissue-engineered vascular grafts could provide a readily available, patient-specific, autologous tissue source that could significantly improve outcomes in newborns with congenital heart disease. Here, we present the recent case of a candidate for our tissue-engineered vascular graft clinical trial deemed ineligible due to complex anatomical requirements and consider the application of three-dimensional printing technologies for a patient-specific graft. We 3D-printed a closed-disposable seeding device and validated that it performed equivalently to the traditional open seeding technique using ovine bone marrow-derived mononuclear cells. Next, our candidate's preoperative imaging was reviewed to propose a patient-specific graft. A seeding apparatus was then designed to accommodate the custom graft and 3D-printed on a commodity fused deposition modeler. This exploratory feasibility study represents an important proof of concept advancing progress toward a rationally designed patient-specific tissue-engineered vascular graft for clinical application.

  7. Prevalence of Radiographic Knee Osteoarthritis After Anterior Cruciate Ligament Reconstruction, With or Without Meniscectomy: An Evidence-Based Practice Article.

    Science.gov (United States)

    Ruano, Jennifer S; Sitler, Michael R; Driban, Jeffrey B

    2017-06-02

    Reference:  Claes S, Hermie L, Verdonk R, Bellemans J, Verdonk P. Is osteoarthritis an inevitable consequence of anterior cruciate ligament reconstruction? A meta-analysis. Knee Surg Sports Traumatol Arthrosc. 2013;21(9):1967-1976.   What is the prevalence of radiographic knee osteoarthritis (OA) at a mean follow-up equal to or greater than 10 years after autologous anterior cruciate ligament (ACL) reconstruction, with or without meniscectomy?   The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) reporting guidelines were used to conduct this meta-analysis. Studies were identified by searching PubMed, MEDLINE, EMBASE, and Cochrane Library dating from their earliest file until October 2010. Key terms applied for searching were anterior cruciate ligament or ACL, autologous, follow-up, long-term, outcome, reconstruction, results, treatment, and (osteo)arthritis or osteoarthrosis. The reference lists of included studies were also manually checked to ensure that relevant articles were not omitted.   The authors limited their search to English- and French-language journals. Included studies provided radiographic outcomes after autologous ACL reconstruction and had a mean follow-up of ≥10 years. Excluded studies evaluated ACL reconstruction with major concomitant surgical procedures (eg, meniscal allograft transplantation, high tibial osteotomy). In addition, data from 2 studies completed by the same research team with identical patient populations were limited to the article with the longest follow-up. Finally, manuscripts with inaccurate or incomplete data were excluded.   The following key characteristics of each study were extracted: type of study (prospective or retrospective); ACL surgical procedure (eg, open or arthroscopic bone-patellar tendon-bone graft); time frame of surgery; mean follow-up (in years) post-ACL reconstruction; total number of participants with radiographs; total number of participants with radiographic OA

  8. Autologous fat grafting: use of closed syringe microcannula system for enhanced autologous structural grafting

    Directory of Open Access Journals (Sweden)

    Alexander RW

    2013-04-01

    Full Text Available Robert W Alexander,1 David Harrell2 1Department of Surgery, School of Medicine and Dentistry, University of Washington, Seattle, WA, USA; 2Harvest-Terumo Inc, Plymouth, MA, USA Objectives: Provide background for use of acquiring autologous adipose tissue as a tissue graft and source of adult progenitor cells for use in cosmetic plastic surgery. Discuss the background and mechanisms of action of closed syringe vacuum lipoaspiration, with emphasis on accessing adipose-derived mesenchymal/stromal cells and the stromal vascular fraction (SVF for use in aesthetic, structural reconstruction and regenerative applications. Explain a proven protocol for acquiring high-quality autologous fat grafts (AFG with use of disposable, microcannula systems. Design: Explain the components and advantage of use of the patented super luer-lock and microcannulas system for use with the closed-syringe system. A sequential explanation of equipment selection for minimally traumatic lipoaspiration in small volumes is presented, including use of blunt injection cannulas to reduce risk of embolism. Results: Thousands of AFG have proven safe and efficacious for lipoaspiration techniques for large and small structural fat grafting procedures. The importance and advantages of gentle harvesting of the adipose tissue complex has become very clear in the past 5 years. The closed-syringe system offers a minimally invasive, gentle system with which to mobilize subdermal fat tissues in a suspension form. Resulting total nuclear counting of undifferentiated cells of the adipose-derived -SVF suggests that the yield achieved is better than use of always-on, constant mechanical pump applied vacuum systems. Conclusion: Use of a closed-syringe lipoaspiration system featuring disposable microcannulas offers a safe and effective means of harvesting small volumes of nonmanipulated adipose tissues and its accompanying progenitor cells within the SVF. Closed syringes and microcannulas are

  9. Adequacy of Semitendinosus Tendon Alone for Anterior Cruciate Ligament Reconstruction Graft and Prediction of Hamstring Graft Size by Evaluating Simple Anthropometric Parameters

    OpenAIRE

    Stergios, Papastergiou G.; Georgios, Konstantinidis A.; Konstantinos, Natsis; Efthymia, Papathanasiou; Nikolaos, Koukoulias; Alexandros, Papadopoulos G.

    2012-01-01

    Introduction. Preoperative identification of patients with inadequate hamstring grafts for anterior cruciate ligament reconstruction is still a subject of interest. Purpose. The purpose of this study was to determine whether the semitendinosus tendon length is adequate for four-strand graft harvested by common technique (without bone plug) and whether there is correlation of gracilis and semitendinosus tendon grafts length and diameter of quadrupled graft with anthropometric parameters. ...

  10. Grafting single molecule magnets on gold nanoparticles.

    Science.gov (United States)

    Perfetti, Mauro; Pineider, Francesco; Poggini, Lorenzo; Otero, Edwige; Mannini, Matteo; Sorace, Lorenzo; Sangregorio, Claudio; Cornia, Andrea; Sessoli, Roberta

    2014-01-29

    The chemical synthesis and characterization of the first hybrid material composed by gold nanoparticles and single molecule magnets (SMMs) are described. Gold nanoparticles are functionalized via ligand exchange using a tetrairon(III) SMM containing two 1,2-dithiolane end groups. The grafting is evidenced by the shift of the plasmon resonance peak recorded with a UV-vis spectrometer, by the suppression of nuclear magnetic resonance signals, by X-ray photoemission spectroscopy peaks, and by transmission electron microscopy images. The latter evidence the formation of aggregates of nanoparticles as a consequence of the cross-linking ability of Fe4 through the two 1,2-dithiolane rings located on opposite sides of the metal core. The presence of intact Fe4 molecules is directly proven by synchrotron-based X-ray absorption spectroscopy and X-ray magnetic circular dichroism spectroscopy, while a detailed magnetic characterization, obtained using electron paramagnetic resonance and alternating-current susceptibility, confirms the persistence of SMM behavior in this new hybrid nanostructure. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. GRAFT VERSUS HOST DISEASE- ORAL PRESENTATION

    Directory of Open Access Journals (Sweden)

    Pradeep P. S

    2017-09-01

    Full Text Available BACKGROUND Graft-versus-host disease (GVHD is described as a potentially life-threatening complication caused by allogeneic haematopoietic cell transplantation. It is an exaggerated manifestation of a normal inflammatory mechanism in which donor lymphocytes encounter foreign antigens in an atmosphere that promote inflammation. 90% of the patients show oral features in case of cGVHD. Oral mucosal lesions and salivary gland dysfunction are the main oral features of chronic GVHD. Trismus or reduction of the mouth opening due to the perioral deposition of collagen is also commonly seen. Purpose of this review is to understand pathophysiology of oral presentations of GVHD. MATERIALS AND METHODS Review related to GVHD pathophysiology, oral lesions after haematopoietic cell transplant encompassed literature from 1966 through 2015. Review of Medline/PubMed Journals were done. RESULTS It is difficult to describe the pathophysiology of oral manifestations because there is no well accepted definition. CONCLUSION Larger well-designed clinical studies are needed to understand the pathobiology of oral cGVHD and determine best treatments for this disease.

  12. Change in Size of Hamstring Grafts During Preparation for ACL Reconstruction: Effect of Tension and Circumferential Compression on Graft Diameter.

    Science.gov (United States)

    Cruz, Aristides I; Fabricant, Peter D; Seeley, Mark A; Ganley, Theodore J; Lawrence, J Todd R

    2016-03-16

    There is good consensus that anterior cruciate ligament (ACL) grafts should be pretensioned to remove creep prior to implantation, but the literature contains little information on the influence of graft preparation or circumferential compression on graft size. The purpose of this study was to investigate how the size of hamstring allografts changes as they are prepared for ACL reconstruction. We hypothesized that grafts decrease in diameter as they are prepared with both tension and circumferential compression. We also investigated the interrater reliability of graft diameter measurements during each step of graft preparation. Twenty pairs of fresh-frozen human hamstring tendons obtained from an allograft supplier were prepared in a standardized fashion for ACL reconstruction (suturing followed by longitudinal tensioning followed by circumferential compression followed by relaxation). Four blinded raters measured each graft in a sequential manner after each graft preparation step. Interrater reliability was assessed using the intraclass correlation coefficient ICC(2,1). The mean allograft diameter at each time point was calculated and compared across all time points using repeated-measures analysis of variance (ANOVA). Subjecting the grafts to both tension and circumferential compression significantly decreased their mean diameter (to 7.38 mm compared with 8.28 mm at baseline; p = 0.044). Interrater reliability revealed almost perfect agreement at each measurement interval, with the ICC ranging from 0.933 to 0.961. The average diameter of hamstring ACL grafts decreases by almost 1 mm after they are subjected to both tension and circumferential compression within a standard cylindrical sizing block. Because ACL bone tunnels are drilled in 0.5-mm increments, preparing soft-tissue grafts with circumferential compression in addition to tension may allow creation of tunnels that are one to two incremental sizes smaller. This could permit less bone removal, which may be

  13. Preparation of Dimethylaminoethylmethacrylate Grafted Polymeric Adsorbent by Using Radiation-Induced Grafting Technique for Removal of Anions

    International Nuclear Information System (INIS)

    Kavakli, P. A.

    2006-01-01

    The development of efficient separation and purification techniques is very important from industrial, environmental and economic points of view. Polymeric materials having polyfunctional groups such as carboxylic, amide, nitrile, iminodiacetic acid, amidoxime, and ammonium groups, etc., not only possess good hydrophilic properties, but also have good ion exchange properties which make them suitable for metal recovery from aqueous solutions. Radiation induced grafting is a powerful technique capable of controlling the introduction of various functional groups to the polymeric materials, keeping the original properties and especially the mechanical strength of the base material, and thus, allowing the synthesis of more stable polymeric adsorbents. The main objective of this study was to develop special polymeric adsorbents to remove NOx and PO 4 anions from aqueous systems. For this purpose, a novel nonwoven fabric was prepared by radiation-induced graft polymerization of imethylaminoethylmethacrylate (DMAEMA) onto polypropylene coated polyethylene nonwoven fabric. The trunk polymer was irradiated by electron beam at a voltage of 2 MeV and a current of 3 mA in a nitrogen atmosphere at dry-ice temperature at different doses. The degree of grafting was determined as a function of the total dose, monomer concentration, temperature, and reaction time. It was found that the degree of grafting of grafted polymer was greatly affected by reaction conditions. Grafting conditions were optimized, and about 150 % degree of grafting samples was used for further experiments. DMAEMA grafted polymer was later protonated by using acid solution to prepare adsorbent for the removal of anions. Adsorption experiments were performed in column mode for removal of phosphate. Approximately 2000 bed volumes of phosphate-free water can be produced from 10 ppb phosphate solution at high space velocity

  14. Synthesis of Radiation Grafted Polymer Matrices for Separation and Industrial Applications

    International Nuclear Information System (INIS)

    Bhardwaj, Y.K.; Virendra, K.; Goel, N.K.; Sarma, K.S.S.; Sabharwal, S.

    2012-01-01

    Grafting of acrylonitrile onto non-woven porous polypropylene fibre sheet using electron beam was carried out by post-irradiation grafting. Grafting extent of ∼125% was achieved. The grafted nitrile groups were amidoximated and studied for uranium uptake from sea water and heavy metal ions (Co 2+ , Ni 2+ , Mn 2+ , and Cd 2+ ) from aqueous solutions. Adsorption and elution of adsorbed ions in suitable eluents was studied. The grafting process was upgraded to pilot scale to obtain 1x1 m 2 sheets. Mutual radiation grafting technique was used for grafting of vinylbenzyltrimethyl ammonium chloride, [2- (methacryloyloxy)ethyl] trimethylammonium chloride and [2-(acryloyloxyethyl)]trimethylammonium chloride onto cotton cellulose substrate. The grafted matrices showed significantly higher water uptake and good water retention properties. The antibacterial efficacy of the grafted products was found to be a function of extent of grafting and the type of bacteria (Escherichia coli, Pseudomonas flourescens, Staphylococcus aureus and Bacillus cereus). PVBT-g-cotton was studied for its protein adsorption behaviour in continuous column process using Bovine serum albumin (BSA) as a model protein. Mutual radiation grafting technique was used to graft acrylic acid on micrometer thick micro-porous polypropylene membrane. Contact angle measurement studies showed that initial grafting as well as radiation treatment of poly(propylene) in aqueous medium and in presence of Mohr's salt enhances its affinity towards the grafting solution. The enhancement in the polar component of surface energy of treated polypropylene membrane is the primary cause of grafting enhancement. The membranes grafted to an extent of ∼20% were found to perform comparably with the battery separator presently being used by battery industry. Acrylic acid was grafted to Teflon scrap by mutual radiation grafting technique. The grafting extent decreased with increasing dose rate and thickness of the substrate. The

  15. The occurrence of osteoarthritis at a minimum of ten years after reconstruction of the anterior cruciate ligament

    Directory of Open Access Journals (Sweden)

    Patt Thomas W

    2008-06-01

    Full Text Available Abstract Objective The objective of this study was to evaluate the incidence of radiographic osteoarthritis in the operated knee in comparison with the contralateral knee ten years after a bone-tendon bone patellar autograft ACL-reconstruction and to evaluate to which level patients regain activity ten years after reconstruction. Methods Fifty-three patients with ACL instability were operated arthroscopically using the central third of the patellar tendon as a bone-tendon-bone autograft. At a minimum of 10 year follow up 28/44 patients matched the inclusion criteria and could be reached for follow-up. Evaluation included a patient satisfaction evaluation using a Visual Analog Scale, physical examination (International Knee Documentation Committee score, Tegner score, Lysholm score, KT-1000 stabilometry and a radiological evaluation (Kellgren and Fairbanks classification. Results The patients' satisfaction, at a mean of 10,3 year follow-up, measured with a VAS score (0–10 was high with a mean of 8.5 (range 4 to 10. The KT 1000 arthrometer laxity measurements revealed in 55% of the patients an A rating (1–2 mm, in 29% a B rating (3–5 mm and in 16% a C rating (6–10 mm. According to the Tegner score 54% of the patients were able to perform at the same activity level as pre-operatively. The mean pre-operative Tegner score was 6.8 and the mean post-operative Tegner score was 6.0 at final follow up. The Lysholm score showed satisfactory results with a mean of 91 points (range 56 to 100. According to the Kellgren and Fairbank classifications, there is a significant difference (p Conclusion The patellar BTB ACL reconstruction does not prevent the occurrence of radiological OA after 10 years but does help the patient to regain the pre-operative level of activity.

  16. Salt-Induced Control of the Grafting Density in Poly(ethylene glycol) Brush Layers by a Grafting-to Approach

    DEFF Research Database (Denmark)

    Ortiz, Roberto; Olsen, Stefan; Thormann, Esben

    2018-01-01

    In this work, a method to obtain control of the grafting density during the formation of polymer brush layers by the grafting-to method of thiolated poly(ethylene glycol) onto gold is presented. The grafting density of the polymer chains was adjusted by adding Na2SO4 in concentrations between 0...

  17. Perivenous support reduces early changes in human vein grafts : Studies in whole blood perfused human vein segments

    NARCIS (Netherlands)

    Stooker, W; Niessen, HWM; Baidoshvili, A; Wildevuur, WR; Van Hinsbergh, VWH; Fritz, J; Wildevuur, CRH; Eijsman, L

    Background: Patency of vein grafts in coronary artery bypass grafting procedures is generally less favorable than those of selected arterial grafts. However, vein grafts still are needed in cardiac operations. It would be desirable to find measures to improve the patency of vein grafts next to

  18. Three-dimensional computed tomography angiography of coronary artery bypass graft with electron beam tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hoshi, Toshiko; Yamauchi, Tatsuo; Kanauchi, Tetsu; Konno, Miyuki; Imai, Kamon; Suwa, Jiro; Onoguchi, Katsuhisa; Hashimoto, Kazuhiro; Horie, Toshinobu [Saitama Cardiovascular and Respiratory Center, Konan (Japan)

    2001-10-01

    Assessment of coronary artery bypass graft patency by three-dimensional reconstructed computed tomography angiography (3D-CTA) derived from electrocardiography-gated contrast-enhanced electron beam tomography (EBT) was evaluated. Thirty-nine patients with 99 grafts (45 arterial grafts and 54 venous grafts) underwent 3D-CTA and selective coronary angiography within a 3-week interval. 3D-CTA images of the coronary bypass grafts were compared with the coronary angiography images used as the control. 3D-CTA defined 42 of 44 arterial grafts as patent (sensitivity: 95%), all 47 venous grafts as patent (sensitivity: 100%) and all 7 venous grafts as occlusive (specificity: 100%). The overall sensitivity and specificity were 98% and 88%, respectively. 3D-CTA is an useful noninvasive technique with adequate sensitivity and specificity to assess coronary artery bypass graft patency. (author)

  19. Hydrophilicity improvement of polyethersulfone powders by grafting acrylic acid with γ-ray simultaneous irradiation method

    International Nuclear Information System (INIS)

    Deng Bo; Hou Zhengchi; Zhang Fengying; Xie Leidong; Li Jing; Yang Haijun

    2005-01-01

    Acrylic acid was grafted to Polyethersulfone (PES) powders by liquid-phase simultaneous irradiation. Effects of grafting conditions, such as absorbed dose, volume fraction of monomer, inhibitor (Cu 2+ ) concentration, and pH of the grafting solution on degree of the grafting were investigated. Combined with gravimetric analysis, a working curve of grafting degree through FT-IR quantitative analysis was obtained. The highest grafting degree was achieved at dose of 25 kGy, volume fraction of monomer of 30% and inhibitor concentration of 0.004 mol/L. Greater degrees of the grafting could be obtained by adding increasing amount of hydrochloric acid to the system. Hydrophilicity of the grafted PES powders increased with higher degrees of the grafting. (authors)

  20. Optimization of process parameter for graft copolymerization of glycidyl methacrylate onto delignified banana fibers

    International Nuclear Information System (INIS)

    Selambakkannu, S.; Nor Azillah Fatimah Othman; Siti Fatahiyah Mohamad

    2016-01-01

    This paper focused on pre-treated banana fibers as a trunk polymer for optimization of radiation-induced graft copolymerization process parameters. Pre-treated banana fiber was grafted with glycidyl methacrylate (GMA) via electron beam irradiation. Optimization of grafting parameters in term of grafting yield was analyzed at numerous radiation dose, monomer concentration and reaction time. Grafting yield had been calculated gravimetrically against all the process parameters. The grafting yield at 40 kGy had increases from 14 % to 22.5 % at 1 h and 24 h of reaction time respectively. Grafting yield at 1 % of GMA was about 58 % and it increases to 187 % at 3 % GMA. The grafting of GMA onto pre-treated banana fibers confirmed with the characterization using FTIR, SEM and TGA. Grafting of GMA onto pre-treated fibers was successfully carried out and it was confirmed by the results obtained via the characterization. (author)

  1. Polymeric flocculant based on cassava starch grafted polydiallyldimethylammonium chloride: Flocculation behavior and mechanism

    International Nuclear Information System (INIS)

    Razali, M.A.A.; Ariffin, A.

    2015-01-01

    Graphical abstract: - Highlights: • Flocculation performance of cassava grafted polyDADMAC was studied. • Turbidity and TSS removal increased with increasing grafting percentage. • The grafted polymer showed good removal in acidic and neutral region. • Zeta potential results pointed to the charge neutralization mechanism. • Flocs increased with increasing grafting percentage and molecular weight. - Abstract: In this work, flocculation properties of cassava starch grafted polydiallyldimethylammonium chloride (polyDADMAC) with different grafting percentages were investigated. Flocculation performance was evaluated in simulated kaolin suspension. The grafting percentages used were 1.76 %, 14.84 %, and 21.98 %. The effectiveness of the flocculation was measured based on the reduction of the turbidity and total suspended solids (TSSs), zeta potential measurements, particle size, and atomic force microscopy imaging. Grafted polymers improved the removal rate of turbidity and TSS compared with gelatinized starch, and the removal rate increased with increasing grafting percentage and dosage

  2. Study of maleic anhydride and styrene grafted onto polypropylene induced by UV irradiation

    International Nuclear Information System (INIS)

    Li Zhenzhong; He Wei; Guo Hongjun; Zhang Wenxiong; Ma Yalin

    2007-01-01

    Maleic anhydride (MAH) and styrene (St) grafted onto polypropylene (PP) were prepared by UV irradiation. Effects of the irradiation time, monomer and initiator content on the grafting rate and melt flow rate (MFR) were studied. The results show that the optimal duration of UV irradiation is 30s. The grafting rate increases with initiator content when initiator content less than 0.6 phr, the MFR value of grafted PP reaches the highest point when benzophenone (BP) content is 0.4 phr. The content of MAH and St have an effect on the grafting rate and MFR value of the grafted PP, and the optimal contents of monomer is 4 phr. The existence of St as a comonomer reduces apparently the MFR value of grafted PP greatly. Grafted PP present significant changes in crystallization and fusion peaks, indicating differences in crystal size and formation after grafting reaction. (authors)

  3. Pre-irradiation induced emulsion graft polymerization of acrylonitrile onto polyethylene nonwoven fabric

    International Nuclear Information System (INIS)

    Liu Hanzhou; Yu Ming; Deng Bo; Li Linfan; Jiang Haiqing; Li Jingye

    2012-01-01

    Acrylonitrile has been widely used in the modification of polymers by graft polymerization. In the present work, pre-irradiation induced emulsion graft polymerization method is used to introduce acrylonitrile onto PE nonwoven fabric instead of the traditional reaction in organic solvents system. The degree of grafting (DG) is measured by gravimetric method and the kinetics of the graft polymerization is studied. The existence of the graft chains is proven by Fourier transform infrared spectroscopy (FT-IR) analysis. Thermal stability of the grafted polymer is measured by Thermogravimetric analysis (TGA). - Highlights: → Acrylonitrile is grafted onto pre-irradiated polyethylene (PE) nonwoven fabrics. → Emulsion system is applied, for the graft polymerization avoids organic solvent. → Kinetic of the pre-irradiation induced graft polymerization is studied. → Optimal condition is determined at the temperature below the b.p. of acrylonitrile.

  4. Full-thickness skin grafting to cover equine wounds caused by laceration or tumor resection.

    Science.gov (United States)

    Tóth, Ferenc; Schumacher, Jim; Castro, Fernando; Perkins, Justin

    2010-08-01

    To describe and evaluate full-thickness skin grafting of equine wounds. Case series. Adult horses (n=6). A full-thickness graft was harvested from the pectoral region with the horse anesthetized or standing and sedated after local anesthetic infiltration. Grafts were attached to the cutaneous margin of the wound with staples and/or sutures if the horse was anesthetized or if the recipient site was desensitized. Cyanoacrylate glue was used to attach the grafts to the cutaneous margin of the wound of 3 horses. Medical records were reviewed for history, physical examination findings, grafting technique, postoperative complications, and outcome. Three horses had full-thickness skin grafting to cover a fresh defect created by excision of a cutaneous neoplasm, and 3 horses had full-thickness skin grafting to cover a fresh or granulating laceration. Grafts were completely accepted in 5 horses. The superficial layers of all grafts sloughed, but the final cosmetic appearance of accepted grafts was good. Full-thickness skin grafting can be performed in standing sedated horses with good cosmesis, especially when the meshed graft is expanded minimally. Good acceptance of a full-thickness graft can be expected, regardless of whether the graft is applied to a fresh or granulating wound.

  5. Using negative pressure therapy for improving skin graft taking on genital area defects following Fournier gangrene.

    Science.gov (United States)

    Orhan, Erkan; Şenen, Dilek

    2017-09-01

    Fournier's gangrene is an infective necrotizing fasciitis of the perineal, genital and perianal regions. Treatment includes aggressive surgical debridement that often results in extensive loss of genital skin. Skin grafts may be used for reconstruction but skin grafting of the male genitalia is diffucult because the penis and scrotum are mobile and deformable. A variety of methods are used to secure skin graft to recipient beds. We used negative pressure therapy (NPT) to secure skin grafts and improve skin graft taking. We used negative pressure therapy for graft fixation in 13 male patients who underwent debridements with the indication of Fournier gangrene, and whose defects formed were reconstructed with grafts between January 2009, and January 2014. Information about age of the patients, sessions of negative pressure therapy applied before, and after reconstruction, duration of hospital stay, and graft losses during postoperative period were recorded. Median age of the patients was 56.15 (46-72) years. NPT was applied to patients for an average of 6.64 sessions (4-12) before and 1 sessions after graft reconstruction. Patients were hospitalized for an average of 26.7 (20-39) days. Any graft loss was not seen after NPT. Because of the peculiar anatomy of the genital region, anchoring of grafts is difficult so graft losses are often encountered. Use of NPT for ensuring graft fixation on the genital region prevents skin graft shearing.

  6. Marginal bone loss in implants placed in grafted maxillary sinus.

    Science.gov (United States)

    Galindo-Moreno, Pablo; Fernández-Jiménez, Andrés; O'Valle, Francisco; Silvestre, Francisco J; Sánchez-Fernández, Elena; Monje, Alberto; Catena, Andrés

    2015-04-01

    The purpose of this study is to evaluate the vertical and horizontal graft bone resorption (GR) in grafted maxillary sinuses and the marginal bone loss (MBL) around implants placed in the sinuses with different prosthetic connections and to determine the effect of other clinical factors on these tissue responses at 6 and 18 months postloading. A total of 254 implants were placed in 150 grafted maxillary sinuses of 101 patients (51.5% female) with mean age of 52.2 years (range, 32-82 years). GR and MBL measurements were made in implants placed with two different prosthetic connections (internal and external) at 6 and 18 months postloading. The complex samples general linear model was used to analyze the influence of patient age, gender, smoking habit, history of periodontal disease, implantation timing (simultaneous vs deferred), and prosthetic abutment length on radiographic GR and MBL values. At 18 months postloading, the MBL ranged from 0 mm to 5.89 mm; less than 1 mm was lost around 49.0% (mesial) and 44.3% (distal) of the implants, while no bone was lost around 32.9% (mesial) and 26.7% (distal). The GR was significantly affected by smoking, remnant alveolar bone height, graft length, graft height, gender, and age, and it significantly decreased over time. The MBL was influenced by the type of connection, implantation timing, and prosthetic abutment length. The MBL was greater with longer postloading interval and higher patient age and in smokers. Resorption of grafts that combine autogenous cortical bone with anorganic bovine bone is dependent on the anatomic features of the sinus and is not affected by the time elapsed after the first 6 months. The MBL in implants placed in these grafted areas is time dependent and mainly related to potentially modifiable clinical decisions and patient habits. © 2013 Wiley Periodicals, Inc.

  7. Marginal grafts increase early mortality in liver transplantation

    Directory of Open Access Journals (Sweden)

    Telesforo Bacchella

    Full Text Available CONTEXT AND OBJECTIVE: Expanded donor criteria (marginal grafts are an important solution for organ shortage. Nevertheless, they raise an ethical dilemma because they may increase the risk of transplant failure. This study compares the outcomes from marginal and non-marginal graft transplantation in 103 cases of liver transplantation due to chronic hepatic failure. DESIGN AND SETTING: One hundred and three consecutive liver transplantations to treat chronic liver disease performed in the Liver Transplantation Service of Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo between January 2001 and March 2006 were retrospectively analyzed. METHODS: We estimated graft quality according to a validated scoring system. We assessed the pre-transplantation liver disease category using the Model for End-Stage Liver Disease (MELD, as low MELD ( 20. The parameters for marginal and non-marginal graft comparison were the one-week, one-month and one-year recipient survival rates, serum liver enzyme peak, post-transplantation hospital stay and incidence of surgical complications and retransplantation. The significance level was 0.05. RESULTS: There were no differences between the groups regarding post-transplantation hospital stay, serum liver enzyme levels and surgical complications. In contrast, marginal grafts decreased overall recipient survival one month after transplantation. Furthermore, low-MELD recipients of non-marginal grafts showed better one-week and one-month survival than did high-MELD recipients of marginal livers. After the first month, patient survival was comparable in all groups up to one year. CONCLUSION: The use of marginal graft increases early mortality in liver transplantation, particularly among high-MELD recipients.

  8. Modification of an endovascular stent graft for abdominal aortic aneurysm

    Science.gov (United States)

    Moloye, Olajompo Busola

    Endovascular surgery is currently used to treat abdominal aortic aneurysms (AAA). A stent graft is deployed to exclude blood flow from the aneurysm sac. It is an effective procedure used in preventing aneurysm rupture, with reduced patient morbidity and mortality compared to open surgical repair. Migration and leakage around the device ("endoleak") due to poor sealing of the stent graft to the aorta have raised concerns about the long-term durability of endovascular repair. A preliminary study of cell migration and proliferation is presented as a prelude to a more extensive in vivo testing. A method to enhance the biological seal between the stent graft and the aorta is proposed to eliminate this problem. This can be achieved by impregnating the stent graft with 50/50 poly (DL-lactide co glycolic acid) (PLGA) and growth factors such as basic fibroblast growth factor (bFGF) or connective tissue growth factor (CTGF), at the proximal and distal ends. It is hypothesized that as PLGA degrades it will release the growth factors that will promote proliferation and migration of aortic smooth muscle cells to the coated site, leading to a natural seal between the aorta and the stent graft. In addition, growth factor release should promote smooth muscle cell (SMC) contraction that will help keep the stent graft in place at the proximal and distal ends. It is shown that a statistically significant effect of increased cell proliferation and migration is observed for CTGF release. Less of an effect is noted for bFGF or just the PLGA. The effect is estimated to be large enough to be clinically significant in a future animal study. The long term goal of this study is to reduce migration encounter after graft deployment and to reduce secondary interventions of EVAR especially for older patients who are unfit for open surgical treatment.

  9. Delayed allogeneic skin graft rejection in CD26-deficient mice.

    Science.gov (United States)

    Zhao, Xiangli; Zhang, Kai; Daniel, Peter; Wisbrun, Natali; Fuchs, Hendrik; Fan, Hua

    2018-03-23

    Organ transplantation is an effective therapeutic tool for treating many terminal diseases. However, one of the biggest challenges of transplantation is determining how to achieve the long-term survival of the allogeneic or xenogeneic transplant by, for example, preventing transplant rejection. In the current study, CD26 gene-knockout mice were used to investigate the potential role of CD26/dipeptidyl peptidase-4 (DPPIV) in allogeneic skin graft rejection by tail-skin transplantation. Compared with wild-type (CD26 +/+ ) counterparts, CD26 -/- mice showed reduced necrosis of grafts and delayed graft rejection after skin transplantation. Concentrations of serum IgG, including its subclasses IgG1 and IgG2a, were significantly reduced in CD26 -/- mice during graft rejection. Moreover, after allogeneic skin transplantation, the secretion levels of the cytokines IFN-γ, IL-2, IL-6, IL-4, and IL-13 were significantly reduced, whereas the level of the cytokine IL-10 was increased in the serum of CD26 -/- mice compared with that in the serum of CD26 +/+ mice. Additionally, the concentration of IL-17 in serum and the percentage of cells secreting IL-17 in mouse peripheral blood lymphocytes (MPBLs) were both significantly lower, while the percentage of regulatory T cells (Tregs) was significantly higher in MPBLs of CD26 -/- mice than in those of CD26 +/+ mice. Furthermore, a lower percentage of CD8 + T cells in MPBLs and fewer infiltrated macrophages and T cells in graft tissues of CD26 -/- mice were detected during graft rejection. These results indicate that CD26 is involved in allogeneic skin graft rejection and provides another hint that CD26 deficiency leads to less rejection due to lower activation and proliferation of host immune cells.

  10. Synthesis and properties of silane-fluoroacrylate grafted starch.

    Science.gov (United States)

    Qu, Jia; He, Ling

    2013-10-15

    The latex of silane-fluoroacrylate grafted starch for coating materials, VTMS-starch/P(MMA/BA/3FMA), is obtained by two step grafting reactions. Vinyltrimethoxysilane (VTMS) is primarily grafted onto starch by condensation between Si-OH and C-OH at 120 °C, and then the copolymer of methyl methacrylate (MMA), butyl acrylate (BA) and 2,2,2-trifluoroethyl methacrylate (3FMA) is grafted onto the VTMS-starch by emulsion polymerization. Fourier transform infrared spectrometry (FTIR) and X-ray photoelectron spectroscopy (XPS) have been used to confirm the chemically grafting reactions in every step. The conversion percent, grafting percent and grafting efficiency for VTMS-starch/p(MMA/BA/3FMA) latex indicate that the optimum conditions should be controlled at 75 °C for 1h as VTMS-starch/P(MMA/BA/3FMA) in 1/3 weight ratio. Transmission electron microscopy (TEM) and dynamic light scattering (DLS) analysis have revealed that the latexes exhibit the uniform spherical particles of 40-60 nm in a narrow size distribution. The latex films perform the obvious hydrophobic (107°) property, lower surface free energy (25-35 mN/m) and the higher thermostability (330-440 °C) than starch (51°, 51.32 mN/m, 100-330 °C). Dynamic thermomechanical analysis (DMA) shows that the latex film could gain considerable toughness and strength with an elongation at break of 39.45% and a tensile strength of 11.97 MPa. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Vitiligo: characterization of melanocytes in repigmented skin after punch grafting.

    Science.gov (United States)

    Kovacs, D; Abdel-Raouf, H; Al-Khayyat, M; Abdel-Azeem, E; Hanna, M R; Cota, C; Picardo, M; Anbar, T S

    2015-03-01

    Punch grafting is a surgical technique mainly applied in therapy-resistant, stable and circumscribed vitiligo. (i) To characterize in detail the features of the repigmented skin among punch grafts; and (ii) to correlate the ex vivo results with clinical data and punch grafting outcome. We evaluated by immunohistochemistry and image analysis the expression of a panel of specific melanocyte markers including HMB45, MITF, c-kit, MART-1 and TRP1, the proliferation marker Ki67 and the cell-cell adhesion molecule E-cadherin in tissue samples collected from nine patients after punch grafting. Cells positive for MITF, c-kit, MART-1 and TRP1 were detected in the repigmented skin of all biopsies, whereas no reactivity was observed for HMB45. Melanocytes were identified along the entire length of the sections, and their mature state was assessed by the immuno-reactivity for the differentiation marker MART-1, the absence of cells positively stained for Ki67 and by the co-expression of c-kit and TRP1, a marker of a differentiated and pigmented state. Clinically, smaller punch grafts aimed at repigmenting lesional areas on the face gave the faster clinical results with no side-effects. Patients subjected to bigger punch grafts on the knee exhibited a longer repigmentation time and presented cobble stoning. Our results suggest that the repigmentation observed in the areas between the grafts is due to the activation of the melanocytes located in the donor sites. These cells start to horizontally migrate towards the lesional skin thanks to successively the enlargement of intercellular spaces in relation to a decrease of E-cadherin reactivity and the up-modulation of pro-melanogenic mediators. Production and transfer of melanin in the surrounding keratinocytes and their persistence were assessed by the reactivity for MITF, c-kit, MART-1 and TRP1 but not for the pre-melanosome marker (HMB45). © 2014 European Academy of Dermatology and Venereology.

  12. Outcomes of the overlay graft technique in tympanoplasty.

    Science.gov (United States)

    Ryan, Jennifer E; Briggs, Robert J S

    2010-09-01

    This audit was undertaken to review the outcomes achieved with the overlay graft technique of tympanic membrane repair in tympanoplasty surgery. The charts of all patients who underwent tympanoplasty, in whom an overlay graft technique of temporalis fascia tympanic membrane repair was used, between 1994 and 2007 were reviewed. Information with respect to patient demographics, presence of cholesteatoma or active infection and perforation size was documented. Details of the surgical procedure and clinical outcomes and pre- and post-operative hearing thresholds were recorded in a computer database. A total of 147 overlay graft procedures were performed in 130 patients. Graft failure with reperforation occurred following five procedures, for an overall success rate of 96.6%. Eighty Type 1 tympanoplasty procedures were performed in which one failure occurred for a 98.75% success rate. Overlay grafting was combined with intact canal wall mastoidectomy (ICW) in 38 cases and with modified radical mastoidectomy (MRM) in 17 cases for a success rate of 93.8 and 95%, respectively. Delayed graft healing as a result of infection, problems such as epithelial pearl, blunting and myringitis occurred in 39 cases (26.5%). Thirty-one cases underwent procedures for ossicular chain reconstruction, 21 of which were 2nd stage procedures. Hearing outcomes were significantly better with Type 1 tympanoplasty compared with ICW or MRM procedures. This review demonstrates the overlay graft technique of tympanoplasty to be highly successful for tympanic membrane repair, particularly for the more difficult cases such as revision surgery, subtotal perforations and mesotympanic cholesteatoma. © 2010 The Authors. ANZ Journal of Surgery © 2010 Royal Australasian College of Surgeons.

  13. Comparison of Alloderm and mucosal graft in mandibular vestibuloplasty

    Directory of Open Access Journals (Sweden)

    Mahmoodhashemi H.

    2009-12-01

    Full Text Available "nBackground and Aim: The usage of free gingival grafts for vestibuloplasty is a routine procedure. The free gingival procedure requires harvesting the graft from a donor site which increases morbidity and the risk of surgical complications. In addition, adequate amount of donor tissue may not be available. Acceptable results of Alloderm application as a substitute for autogenous soft tissue grafts are: Not exposing the patient to an additional surgery, no donor site morbidity, unlimited availability, decreasing the bleeding during the surgery, decreasing the surgical complications, and better color match. The aim of this study was to evaluate the maintenance of the vestibular depth in vestibuloplasty with mucosal graft and Alloderm."nMaterials and Methods: Both methods of anterior mandibular vestibuloplasty by Clark, utilizing Alloderm and mucosal grafts, were employed in ten clinical cases. During the surgeries, half the prepared recipient sites received Alloderm, while the remaining half received autografts in a randomized fashion. Immediately, 1, 3, and 6 months postoperatively, the variables of graft rejection, depth of vestibule and the degree of relapse were evaluated. SPSS software was used for analysis of the data and the methods used for "statistical tests" were as follows: Friedman Method, Paired sample t-test, Smirnov-kolmogrove Method. (The statistical significance level was established at P-value<0.05."nResults: The mean difference of the relapse measurements in both methods throughout the survey did not have significant predictive value (P>0.05. Similar results were achieved for the mean difference of depth of the vestibule."nConclusion: In patients undergoing Vestibuloplasty, Alloderm could be material of choice to be utilized as autogenic soft tissue grafts in pre-prosthesis procedures.

  14. Outcomes of hepatitis C- and hepatitis B core antibody-positive grafts in orthotopic liver transplantation.

    Science.gov (United States)

    Saab, Sammy; Chang, Albert J; Comulada, Scott; Geevarghese, Sunil K; Anselmo, R Dean M; Durazo, Francisco; Han, Steven; Farmer, Douglas G; Yersiz, Hasan; Goldstein, Leonard I; Ghobrial, R Mark; Busuttil, Ronald W

    2003-10-01

    The use of hepatitis B core antibody (HBcAb)- and hepatitis C virus antibody (HCV+) liver grafts for transplantation in selected populations has not affected patient and graft survival. We reexamined the clinical outcomes of using these HBcAb+ and HCV+ grafts at our institution, in addition to studying recipients of combined HBcAb+/HCV+ grafts. We identified 377 patients who underwent transplantation for either hepatitis B and/or hepatitis C, or received both HBcAb+ and HCV+ grafts. Patient and graft survival at 5 years posttransplantation was 73% and 71%, respectively, in the HBcAb+ grafts compared with 81% and 75% in the HBcAb- grafts (P =.65; P =.94). For HCV+ grafts, patient and graft survival at 5 years posttransplantation was 89% and 73%, respectively, compared with 69% and 59% in the HCV- grafts; (P =.22; P =.77). The 5-year patient and graft survival rate in those who received combined HBcAb+/HCV+ grafts was 74% and 69%, respectively, and there was no statistical difference compared with the HBcAb+ and HCV+ grafts (P =.76; P =.90). The 5-year patient and graft survival rate in patients who received dual HBV prophylaxis with hepatitis B immunoglobulin (HBIg) and lamivudine was 88% and 84%, respectively, which was significantly higher than for patients who received single prophylaxis or no prophylaxis (P HBcAb+ and HCV+ grafts, and that dual prophylaxis with HBIg and lamivudine offers substantial survival benefits. Furthermore, the use of combined HBcAb+/HCV+ grafts did not impact patient or graft survival. This provides a potential new pool of donor livers that can be used for transplantation in select patients.

  15. Radiation grafting of non-woven fabrics and fibre felts with functional monomers

    International Nuclear Information System (INIS)

    Peltonen, R.T.; Ekman, K.B.; Naesman, J.H.

    1993-01-01

    The radiation-induced grafting of acrylic acid, acrylamide, 4-vinylpyridine and vinylbenzylchloride onto non-woven fabrics and fibre felts of polypropylene and polyethylene was investigated. Electron beams were used to initialize the grafting reactions and the extent of grafting is controlled by varying parameters like radiation dose, reaction temperature and reaction time. It was found that grafting onto non-woven fabrics gives higher extents of grafting compared with fibre felts. There is also a difference in the extent of grafting between polypropylene and polyethylene non-woven fabrics, which can be attributed to their different behaviour upon irradiation

  16. Gamma radiation grafted polymers for immobilization of Brucella antigen in diagnostic test studies

    Science.gov (United States)

    Docters, E. H.; Smolko, E. E.; Suarez, C. E.

    The radiation grafting process has a wide field of industrial applications, and in the recent years the immobilization of biocomponents in grafted polymeric materials obtained by means of ionizing radiations is a new and important contribution to biotechnology. In the present work, gamma preirradiation grafting method was employed to produce acrylics hydrogels onto polyethylene (PE), polyvinyl chloride (PVC) and polystyrene (PS). Two monomers were used to graft the previously mentioned polymers: methacrylic acid (MAAc) and acrylamide (AAm), and several working conditions were considered as influencing the degree of grafting. All this grafted polymers were used to study the possibility of a subsequent immobilization of Brucella antigen (BAg) in diagnostic test studies (ELISA).

  17. Study of PVC membrane grafted by Acrylic Acid, Acrylonitrile and Acrylamide using preirradiation method

    International Nuclear Information System (INIS)

    Kattan, M.; Al-Kasseri, H.

    2015-03-01

    Grafting of acrylic acid, acrylamide and acrylonitrile onto poly vinyl chloride (PVC) films using gamma radiation has been carried out by both type direct and preirradiation methods. The effect of different parameter such as monomer concentration, inhibitor concentration, reaction temperature, reaction time and irradiation dose on the grafting yield were investigated. It was found that the grafting yield depends on these parameters. The grafting yield was strongly monomer dependent and grafting method: the highest was found for AAc by the preirradiation method. The samples were characterized by tensile strength measurement, swilling and ion uptake. The highest increase in swilling was observed on samples grafted with AAc by the preirradiation method.(author)

  18. An unusual case of fistula formation and thrombosis between arteriovenous graft and a native vein

    Directory of Open Access Journals (Sweden)

    Young Sub Kim

    2016-03-01

    Full Text Available Arteriovenous graft for hemodialysis vascular access is a widely used technique with many advantages. However, it has crucial complications with graft thrombosis and infection. We recently experienced an unusual case of arteriovenous graft complication involving graft thrombosis related to fistula formation between the graft and the natural vein with infection. We diagnosed this condition using Doppler ultrasound and computed tomography angiography. Successful surgical treatment including partial graft excision and creation of a secondary arteriovenous fistula using an inadvertently dilated cephalic vein was performed. The dialysis unit staff should keep this condition in mind and try to prevent this complication.

  19. Platlet Rich Plasma (PRP) Improves Fat Grafting Outcomes.

    Science.gov (United States)

    Modarressi, Ali

    2013-01-01

    Autologous fat transfer offers many qualities of a ideal soft tissue filler. Main advantages of fat grafting ensue from the fact that the lipoaspirate tissue is an abundant source of regenerative pluripotential cells. However, the reported rates of fat cell survival vary greatly in the medical literature (10-90%). Different techniques of harvesting, processing, and reinjecting the fat cells are so claimed to be responsible for these differences, without any agreement concerning the best way to process. To address this important disadvantage, we propose the addition of autologous platelet rich plasma (PRP) which is known as a natural reservoir of growth factors stimulating tissue repair and regeneration. This approach is completely autologous and immediately employed without any type of preconditioning. Platelets rich plasma (PRP) preparation included bleeding of 8 ml of blood from patient's peripheral vein in Regen Lab© tubes containing sodium citrate anticoagulant. The whole blood was centrifugated at 1500 g during 3 min. As Regen-tubes contained a special gel separator, 99 % of red blood cells were discarded from the plasma at the bottom of the gel, and >90% of platelets were harvested in 4 ml of plasma on the top of the gel, called the platelet-rich plasma (PRP). The purified fat prepared by Coleman technique was mixed with different amount of PRP for in vitro, in vivo (mice) and clinical experiments: >50% of PRP for skin rejuvenation, superficial scars correction, infraorbital region, ..., and for 20% of PRP with 80% of purified fat for deep filler indication (nasolabial folds, lips, or soft tissue defect). In vitro studies demonstrated that PRP increased fat cells survival rate and stem cells differentiation. Animal models showed that fat graft survival rate was significantly increased by addition of PRP. Several clinical cases confirmed the improvement of wound healing and fat grafting survival in facial reconstruction and aesthetic cases by association of

  20. Clinical testing of Belarusian aortic stent graft system

    Directory of Open Access Journals (Sweden)

    А. П. Шкет

    2016-12-01

    Full Text Available Aim. The study looks at the results of clinical testing of the first Belarusian aortic stent graft system developed and manufactured by a team of specialists from RSPC "Cardiology", Minsk, Belarus, and Belarusian Technical University.Methods. The original system of aortic stent graft includes a delivery system and an aortic stent graft itself. It is used in surgical treatment of complicated and common aneurysms of the thoracic aorta, as well as in cases of concomitant thoracic aneurysms and heart pathology to be treated under cardiopulmonary bypass. Clinical testing of the stent graft was carried out according to the requirements of Ministry of Health of the Republic of Belarus on the basis of three different cardiac hospitals of the country. Results. All the three hospitals treated one patient each. The first patient underwent implantation of the stent graft into the descending thoracic aorta, with the thoracic aorta aneurysm isolated and the aortic valve replaced with bioprosthesis. The second patient underwent ascending aorta and aortic valve replacement with a conduit and implantation of aortic stent graft into the descending thoracic aorta. In the third patient the domestic aortic stent graft was implanted into the descending thoracic aorta with isolation of the thoracic aneurysm; aortic valve and ascending aorta were replaced with ‘MedEng' conduit and the aortic arch was also replaced, with the brachiocephalic arteries re-implanted in place. All the patients were followed-up for both early and long-term outcomes for more than 1 year and were examined by using CT angiography in the early postoperative period and after 1 year. Uncomplicated postoperative course was observed in all the patients. There were no complications in the long-term follow-up as well. CT angiography data confirmed good positioning of the stent graft and good isolation of the aneurysm lumen. Preoperative and postoperative СТ data of one patient are presented in the

  1. Comparison of Mid-Term Graft Patency between On-Pump and Off-Pump Coronary Artery Bypass Grafting.

    Science.gov (United States)

    Seki, Tatsuya; Yoshida, Toshihito

    2017-06-20

    Multiple studies have compared on-pump coronary artery bypass (ONCAB) grafting with off-pump coronary artery bypass (OPCAB) grafting, but the optimal surgical strategy has yet to be established. Furthermore, there is limited evidence regarding mid-term graft patency rates. Between April 2001 and March 2014, 365 consecutive patients underwent isolated coronary artery bypass grafting (CABG; male: 75%; mean age: 69 ± 10 years). After propensity-score-matched analysis, we assessed the results of 67 patients in each group (ONCAB: group A, OPCAB: group B). The mean follow-up period of graft patency and survival rate was 35 ± 37 months and 54 ± 47 months, respectively. There were no significant differences in baseline characteristics between the two groups. There was a trend for an increased number of distal anastomoses in group B as compared to group A (group A vs. group B: 3.8 ± 1.1 vs. 4.1 ± 1.6, P = 0.17). The total graft patency rate was tend to be lower in group A, but not statistically significant (group A: 156 months, 45.2%; group B: 96 months, 72.6%; P = 0.21). There was no difference for survival and major-adverse-cardiac-and-cerebrovascular-events (MACCE) free rate (P = 0.42 and 0.76, respectively). Propensity-score-matched analysis revealed no difference in mid-term survival rate, MACCE free rate, graft patency rates, and number of distal anastomoses between ONCAB and OPCAB groups.

  2. Surface characterization and biological properties study of silicone rubber membrane grafted with phospholipid as biomaterial via plasma induced graft copolymerization.

    Science.gov (United States)

    Hsiue, G H; Lee, S D; Chang, P C; Kao, C Y

    1998-10-01

    Poly(2-methacryloyloxyethyl phosphorylcholine) (pMPC) was grafted onto the surface of a silicon rubber (SR) membrane (pMPC-SR) by plasma induced grafted copolymerization (PIP). Argon plasma was used to activate the SR surfaces. Determination was also made of the influences of grafted copolymerization reaction time, reaction temperature, and monomer concentration on polymerization yield. The surface properties of SR were characterized by ATR-FTIR, ESCA, and SEM. In those analyses the ATR-FTIR spectra indicated that the pMPC grafted onto the SR surface at 1720 and 3300 cm(-1). The elemental composition and different carbon bindings on the surface of the SR were examined by ESCA. An increasing P1s/C1s value g was obtained in the grafted polymerization yield with a concentration of 0.05-0.5M of MPC in the isolated ethanol solution. The surface morphologies of pMPC-SR differed more than those of control and Ar plasma treated surfaces. The difference could have been caused by the homogeneous graft polymerization of pMPC onto the SR membrane. In the biological analyses, protein adsorption on pMPC-SR surfaces was reduced. The reduced level increased with an increase in the pMPC grafted amount. The epithelial cell attachment and growth onto these samples were suppressed. The blood compatibility for a series of pMPC-SR surfaces was examined by platelet adhesion. Blood platelet morphologies in contact with the high ratio of pMPC-SR surfaces were maintained, meaning that in this case the release reaction for platelets never occurred. Consequently, the high amount of pMPC-SR surface had excellent blood compatibility, further suggesting that prevention of adhesion, activation of platelets, and adsorption of blood protein could be achieved.

  3. Genome-wide identification and comparative analysis of grafting-responsive mRNA in watermelon grafted onto bottle gourd and squash rootstocks by high-throughput sequencing.

    Science.gov (United States)

    Liu, Na; Yang, Jinghua; Fu, Xinxing; Zhang, Li; Tang, Kai; Guy, Kateta Malangisha; Hu, Zhongyuan; Guo, Shaogui; Xu, Yong; Zhang, Mingfang

    2016-04-01

    Grafting is an important agricultural technique widely used to improve plant growth, yield, and adaptation to either biotic or abiotic stresses. However, the molecular mechanisms underlying grafting-induced physiological processes remain unclear. Watermelon (Citrullus lanatus L.) is an important horticultural crop worldwide. Grafting technique is commonly used in watermelon production for improving its tolerance to stresses, especially to the soil-borne fusarium wilt disease. In the present study, we used high-throughput sequencing to perform a genome-wide transcript analysis of scions from watermelon grafted onto bottle gourd and squash rootstocks. Our transcriptome and digital gene expression (DGE) profiling data provided insights into the molecular aspects of gene regulation in grafted watermelon. Compared with self-grafted watermelon, there were 787 and 3485 genes differentially expressed in watermelon grafted onto bottle gourd and squash rootstocks, respectively. These genes were associated with primary and secondary metabolism, hormone signaling, transcription factors, transporters, and response to stimuli. Grafting led to changes in expression of these genes, suggesting that they may play important roles in mediating the physiological processes of grafted seedlings. The potential roles of the grafting-responsive mRNAs in diverse biological and metabolic processes were discussed. Obviously, the data obtained in this study provide an excellent resource for unraveling the mechanisms of candidate genes function in diverse biological processes and in environmental adaptation in a graft system.

  4. Dental Hetero-Graft Materials with Nano Hydroxyapatite Surface Treatment.

    Science.gov (United States)

    Kim, Dai-Hwan; Kim, Kyung-Il; Yoon, Seokyoung; Kim, Hyung-Jo; Ahn, Jin-Soo; Jun, Sang Ho; Kang, Ho Chang; Pang, Changhyun; Kim, Jaeyun; Cha, Hyung Joon; Han, Kwon-Hoon; Kim, Dong-Myong; Lee, Jung Heon

    2015-10-01

    We report the development of hydroxyapatite nanoparticle (HAp NP)-functionalized hetero-graft materials (HGMs) for dental applications. These HGMs were prepared by attaching platelet-, needle-, and sphere-shaped HAp NPs to the surface of xenograft materials through chemical conjugation. Although all three HAp NPs contributed to increase the surface area of bone graft material (BGM), the shape of the HAp NPs was a determining factor. Platelet HAp NPs were most effective, because they caused a 48.9% increase in BGM surface area whereas the influence of the spherical NP was only a 6.7% increase. This suggests that geometric factors regarding both the attached HAp NPs and graft material surface are essential in controlling the surface roughness of graft materials. Among the three HAp NPs, it was the platelet HAp NPs that helped to increase the efficacy of the BGM most significantly. Compared with BGM with no HAp NP attachment, HGM with platelet HAp NP ('platelet-HGM) treatment had ~46.1% higher cell attachment and proliferation rate. The MTT assay also showed that the HAp NP-treated hetero-graft materials had negligible cytotoxicity.

  5. Bone graft complications: what can we do to prevent them?

    Science.gov (United States)

    Tandon, Rahul; Herford, Alan S.

    2014-03-01

    Introduction: Bone grafts are commonly used in oral and maxillofacial surgery, helping to restore missing bone structure and provide osseous support. In spite of their reported success, complications can and do arise. Examples include loosening and resorption of the graft, infection, and complete loss of the graft. These complications can potentially lead to larger defects, necessitating additional procedures to correct the problem. This not only causes great discomfort to the patient, but also drains considerable time and resources away from the clinician. Thus, improvements on identifying ways to identify and prevent these complications are constantly being sought. We have performed a literature review and identified several areas in the field of optics that could potentially help solve our problem. Optical Techniques: Raman spectroscopy has been shown to provide a transcutaneous measurement of bone mineral and matrix Raman bands. This could potentially provide surgeons with the ability to more accurately assess bone graft osseointegration. In-vivo near-infrared optical imaging could potentially provide accurate diagnosis of pathologic lesions such as osteosarcoma. Contrast-enhanced ultrasound could be used to detect vascular disturbances and other information related to the transplantation of osseous components. Conclusion: Bone graft complications can be one of the most devastating consequences of osseous surgery. As surgeons, we are constantly searching for ways to identify them earlier and prevent them. We hope that by presenting areas that could be used, we can gain a better insight to ways in which both fields can benefit.

  6. Obtaining of Grafted Planting Material at Some Romanian Tomatoes

    Directory of Open Access Journals (Sweden)

    Madalina Doltu

    2016-11-01

    Full Text Available The tomatoes have highest share in Romanian crops from protected spaces (greenhouses, solariums. The grafting is an agronomical technique that induces or improves some qualities of the tomato cultivars (resistance to soil diseases and pests, resistance to abiotic factors, quantity and quality of fruit production. The research was aimed the establishing of the technological stages for producing of scion and rootstock seedlings from L. esculentum species, to obtain compatible phenotype when is grafted. The observations of this research were conducted on Department of Horticultural Cultures in Protected Spaces from Horting Institute Bucharest. The experience was carry out on a cultivar collection consisting from L. esculentum plants: scions (‘Siriana’–F1 hybrid and ‘Buzău 1600’– variety, creations from the germplasm bank of Research and Development Station for Vegetable Growing Buzău Romania (VDRS Buzău and rootstock (‘Groundforce’–F1 hybrid. The plant diameters were correlated for a grafting by the annexation method, cutting at 45 degrees. The grafting was performed successfully. The technological steps have achieved phenotypic compatibility of the symbiotes when was the grafting by annexation. The technology for producing of scion and rootstock seedlings at these Romanian tomatoes (‘Siriana’ and ‘Buzău’ 1600 was established for the crops in protected spaces in south area of Romania.

  7. Removal of Industrial Pollutants From Wastewater's By Graft Copolymers

    International Nuclear Information System (INIS)

    Hegazy El-Sayed, A.; El-Nagar Abdel-Wahab, M.; Senna Magdy, M.; Zahran Abdel-Hamid, H.

    1999-01-01

    Graft copolymers that obtained by radiation grafting of acrylic acid and acrylamide onto LDPE film were converted to N-hydroxy ethyl amide and hydroxamic acid derivatives respectively. The possible application for the different prepared chemical derivatives of LDPE graft copolymers in metal adsorption from solutions containing a single cation or simulated medium active waste has been investigated. The results showed that the adsorption of Cu(II) metal by different chemical derivatives was greatly affected by different factors such as graft yield, ph value, concentration of metal in the feed solution, immersion time and treatment temperature. The affinity of N-hydroxy ethyl amide derivative toward the different metals was found to be in the order of; Cu(II) >Pd(II) > Cd(II)> Co(II). However, for hydroxamic acid derivative , the affinity order was: Cd(II) > Cu(II) > Co(II). The ESR and IR analysis revealed that the metal ions are chelated through the lone pair of electrons on the -OH and -NH- groups forming a ring structure. The measured metal ion uptake from simulated medium active waste mixture by N-hydroxy ethyl amide derivative was found to follow the following order: Fe> U> Ni> Zr> Zn> Cr. On the other hand, the measured metal uptake by hydroxamic acid derivative was found to follow: Fe>U> Zr> Ca. It is concluded that the prepared grafted copolymers are of interest for metal chelation and could be applied in the field of waste treatment

  8. [Treatment of Buruli ulcer desease by excision and skin graft].

    Science.gov (United States)

    Ouattara, D; Meningaud, J P; Kaba, L; Sica, A; Asse, H

    2004-02-01

    Buruli ulcer is the most common mycobacteria disease after leprosy and tuberculosis. The purpose of our study is to make our contribution to the surgical treatment of Buruli ulcer and to asses our results. One hundred eighteen patients presenting progressive Buruli ulcers were operated on. The surgical procedure included excisions for necrotic lesions and grafts for clean wounds. The results were estimated on the time of hospitalization and appearance of complications. Seventy-three patients (62%) were subjected to excision followed by thin skin grafts and 35 patients (30%) were subjected to grafts only. The number of excision times varies from 1 to 7 per patient and from 1 to 4 for the skin grafts. All our patients heal within a period of 120 days with extremes going from 14 to 265 days. We deplored 26 complications (22%): eight new focus, seven infectious complications, six recurrences, five stiffnesses and ankyloses. The treatment of Buruli ulcer by excision and grafts is efficient but does not prevent recurrences and new focus from happening and for their prevention, it is necessary to discover pharmaceutical molecules that are efficient on Mycobacterium ulcerans.

  9. Improved antifouling properties of photobioreactors by surface grafted sulfobetaine polymers.

    Science.gov (United States)

    Wang, Dongwei; Wu, Xia; Long, Lixia; Yuan, Xubo; Zhang, Qinghua; Xue, Shengzhang; Wen, Shumei; Yan, Chenghu; Wang, Jianming; Cong, Wei

    2017-11-01

    To improve the antifouling (AF) properties of photobioreactors (PBR) for microalgal cultivation, using trihydroxymethyl aminomethane (tris) as the linking agent, a series of polyethylene (PE) films grafted with sulfobetaine (PE-SBMA) with grafting density ranging from 23.11 to 112 μg cm -2 were prepared through surface-initiated atom transfer radical polymerization (SI-ATRP). It was found that the contact angle of PE-SBMA films decreased with the increase in the grafting density. When the grafting density was 101.33 μg cm -2 , it reached 67.27°. Compared with the PE film, the adsorption of protein on the PE-SBMA film decreased by 79.84% and the total weight of solid and absorbed microalgae decreased by 54.58 and 81.69%, respectively. Moreover, the transmittance of PE-SBMA film recovered to 86.03% of the initial value after cleaning, while that of the PE film recovered to only 47.27%. The results demonstrate that the AF properties of PE films were greatly improved on polySBMA-grafted surfaces.

  10. Cross-facial nerve grafting for facial reanimation.

    Science.gov (United States)

    Peng, Grace Lee; Azizzadeh, Babak

    2015-04-01

    Dynamic facial reanimation is the gold standard treatment for a paralyzed face. Over the last century, multiple nerves have been utilized for grafting to the facial nerve in an attempt to produce improved movement. However, in recent years, the use of cross facial nerve grafting with a second stage gracilis free flap has gained popularity due to the ability to generate a spontaneous smile and facial movement. Preoperative history taking and careful examination, as well as pre-surgical planning, are imperative to whether cross facial nerve grafting with a second stage gracilis free flap is appropriate for the patient. A sural nerve graft is ideal given the accessibility of the nerve, the length, as well as the reliability and ease of the nerve harvest. The nerve can be harvested using a small incision, which leaves the patient with minimal post operative morbidity. In this chapter, we highlight the pearls and pitfalls of cross facial nerve grafting. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  11. Use and preservation methods of bone grafts in small animals

    Directory of Open Access Journals (Sweden)

    Rafael Garabet Agopian

    2016-09-01

    Full Text Available http://dx.doi.org/10.5007/2175-7925.2016v29n3p11 The present review describes the main characteristics of bone grafts used in small animals. Bone grafts are tissues without vasculature, which facilitate the production of new bone cells with osteogenic and osteoinductive factors that lead to the differentiation of cells and structural support for bone marrow. The transplant of a graft is followed by three stages: osteogenesis, or the formation of new bone; osteoinduction, which is the differentiation of cells; and osteoconduction, the process of growth of mesenchymal cells and capillaries that results in new bone formation. The composition of bone grafts may include spongy bone, cortical bone, cortical-spongy bone, cartilage or bone marrow. Grafts can also be classified according to their origin, being autogenous tissue when they are transplanted from the same individual, allogenous (homologous when originating from another individual of the same species, and xenogenous when obtained from a different species.

  12. Structure and transport properties of polymer grafted nanoparticles

    KAUST Repository

    Goyal, Sushmit

    2011-01-01

    We perform molecular dynamics simulations on a bead-spring model of pure polymer grafted nanoparticles (PGNs) and of a blend of PGNs with a polymer melt to investigate the correlation between PGN design parameters (such as particle core concentration, polymer grafting density, and polymer length) and properties, such as microstructure, particle mobility, and viscous response. Constant strain-rate simulations were carried out to calculate viscosities and a constant-stress ensemble was used to calculate yield stresses. The PGN systems are found to have less structural order, lower viscosity, and faster diffusivity with increasing length of the grafted chains for a given core concentration or grafting density. Decreasing grafting density causes depletion effects associated with the chains leading to close contacts between some particle cores. All systems were found to shear thin, with the pure PGN systems shear thinning more than the blend; also, the pure systems exhibited a clear yielding behavior that was absent in the blend. Regarding the mechanism of shear thinning at the high shear rates examined, it was found that the shear-induced decrease of Brownian stresses and increase in chain alignment, both correlate with the reduction of viscosity in the system with the latter being more dominant. A coupling between Brownian stresses and chain alignment was also observed wherein the non-equilibrium particle distribution itself promotes chain alignment in the direction of shear. © 2011 American Institute of Physics.

  13. Study on superhydrophobic surfaces of octanol grafted electrospun silica nanofibers

    International Nuclear Information System (INIS)

    Meng, Long-Yue; Han, Shunyu; Jiang, Nanzhe; Meng, Wan

    2014-01-01

    In this work, superhydrophobic surfaces were successfully prepared by grafting of octanol on the surface of electrospun silica nanofibers (SNFs). The chemical compositions and microstructures of the prepared SNFs surfaces were investigated by using N 2 full isotherms, Fourier transform infrared spectroscopy (FT-IR), thermogravimetric analysis (TGA), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and contact angle measurements. The results indicate that the surface of SNFs changed from being superhydrophilic to superhydrophobic by octanol surface grafting. The contact angle of the octanol-grafted SNFs was close to 150.2° because their surface was modified by –(CH 2 ) 6 –CH 3 groups. The 3D network of SNFs networks and the low surface energy of the alkyl side chains played important roles in creating the superhydrophobic surface of the SNFs. - Highlights: • Superhydrophobic surface was prepared from electrospinning SNFs and by grafting octanol on their surface. • The surface of SNFs changed from superhydrophilic to superhydrophobic. • The CA of MSNFs became 150.2° because of interactions between grafted octyl groups

  14. Study on superhydrophobic surfaces of octanol grafted electrospun silica nanofibers

    Energy Technology Data Exchange (ETDEWEB)

    Meng, Long-Yue [Key Laboratory of Natural Resources of Changbai Mountain and Functional Molecules, Yanbian University, Yanji 133002 (China); Department of Chemical Engineering, College of Engineering, Yanbian University, 977 Gongyuan Road, Yanji 133002 (China); Han, Shunyu; Jiang, Nanzhe [Department of Chemical Engineering, College of Engineering, Yanbian University, 977 Gongyuan Road, Yanji 133002 (China); Meng, Wan, E-mail: mengw@ybu.edu.cn [Department of Chemical Engineering, College of Engineering, Yanbian University, 977 Gongyuan Road, Yanji 133002 (China)

    2014-12-15

    In this work, superhydrophobic surfaces were successfully prepared by grafting of octanol on the surface of electrospun silica nanofibers (SNFs). The chemical compositions and microstructures of the prepared SNFs surfaces were investigated by using N{sub 2} full isotherms, Fourier transform infrared spectroscopy (FT-IR), thermogravimetric analysis (TGA), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and contact angle measurements. The results indicate that the surface of SNFs changed from being superhydrophilic to superhydrophobic by octanol surface grafting. The contact angle of the octanol-grafted SNFs was close to 150.2° because their surface was modified by –(CH{sub 2}){sub 6}–CH{sub 3} groups. The 3D network of SNFs networks and the low surface energy of the alkyl side chains played important roles in creating the superhydrophobic surface of the SNFs. - Highlights: • Superhydrophobic surface was prepared from electrospinning SNFs and by grafting octanol on their surface. • The surface of SNFs changed from superhydrophilic to superhydrophobic. • The CA of MSNFs became 150.2° because of interactions between grafted octyl groups.

  15. Surface modification of polypropylene membrane by polyethylene glycol graft polymerization.

    Science.gov (United States)

    Abednejad, Atiye Sadat; Amoabediny, Ghasem; Ghaee, Azadeh

    2014-09-01

    Polypropylene hollow fiber microporous membranes have been used in a wide range of applications, including blood oxygenator. The hydrophobic feature of the polypropylene surface causes membrane fouling. To minimize fouling, a modification consisting of three steps: surface activation in H2 and O2 plasma, membrane immersion in polyethylene glycol (PEG) and plasma graft polymerization was performed. The membranes were characterized by contact angle measurement, Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), tensile test, scanning electron microscopy (SEM) and atomic force microscopy (AFM). Oxygen transfer of modified membranes was also tested. The stability of grafted PEG was measured in water and in phosphate buffer saline (PBS) at 37°C. Blood compatibility of modified surfaces was evaluated by the platelet adhesion method. Water contact angel reduction from 110° to 72° demonstrates the enhanced hydrophilicity, and XPS results verify the presence of oxygenated functional groups due to the peak existence in 286 eV as a result of PEG grafting. The results clearly indicate that plasma graft-polymerization of PEG is an effective way for antifouling improvement of polypropylene membranes. Also, the results show that oxygen transfer changes in PEG grafted membranes are not significant. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Decontamination of nuclear plant fluids with grafted celluloses

    International Nuclear Information System (INIS)

    Sandeaux, R.

    1991-01-01

    Ion exchange processes are specially well adapted techniques to solve some of nuclear plants problems, such as decontamination of the primary cooling circuit fluid and the cooling pool, because of the low concentration of the miscellaneous products to eliminate. Now the purification of these fluids is performed by using ion exchange resins. But recent researches show it is necessary to use more efficient techniques (1). The use of grafted celluloses should improve this process. The manufacturing of grafted celluloses was first performed with the collaboration of French Textile Institute and Morgane-Framatome (2). Cellulosic structure offers well known qualities for filtration: good micrometric retention, good mechanical behaviour, strong hydrophilic properties and high specific surface. Grafting was performed through a radiochemical process so as to bind polyelectrolytes on the backbone polymer. Compared to usual ion exchangers, these new materials offer different properties: - fast exchange kinetic - as uncrosslinked polymers, these grafted celluloses withstand better fouling with macroions or ionic complexes; - as they can be incinerated, radioactive wastes can be greatly reduced; - different commercial products of these grafted celluloses offer a wide range of possibilities for industrial uses [fr

  17. Modification of synthetic fibers by radiation-induced grafting

    International Nuclear Information System (INIS)

    Kaji, Kanako

    1981-05-01

    The present report describes studies to modify properties of synthetic fibers by radiation-induced grafting technique. This technique was employed since it is considered to be generally applicable to the grafting of a radically polymerizable monomer onto fiber. Three synthetic fibers were used mainly in the present studies; (1) polyester fiber which is ranked as the first in the amount of production in the synthetic fibers at present and is expected to increase in its importance in the future, (2) poly (vinyl chloride) fiber which is inexpensive and fire-retardant, and (3) polyethylene fiber which is not yet used in apparel at present. In order to perform the grafting, the following two methods were studied; one is to graft monomer uniformly in the fiber preventing homopolymerization of the monomer outside of the fiber, and the other to graft monomer only on the fiber surface. Using these methods, the following experiments were carried out and fairly good results as expected were obtained. (1) In the case of polyester fiber it was intended to make this more hydrophilic and fire-retardant. (2) Concerning to poly(vinyl chloride) fiber experiments were carried out to make the fiber more hydrophilic and simultaneously more heat-resistant. (3) In the case of polyethylene fiber, target was fire-retardance and heat-resistance. (author)

  18. A Review on Grafting of Biofibers for Biocomposites

    Directory of Open Access Journals (Sweden)

    Liqing Wei

    2016-04-01

    Full Text Available A recent increase in the use of biofibers as low-cost and renewable reinforcement for the polymer biocomposites has been seen globally. Biofibers are classified into: lignocellulosic fibers (i.e., cellulose, wood and natural fibers, nanocellulose (i.e., cellulose nanocrystals and cellulose nanofibrils, and bacterial cellulose, while polymer matrix materials can be petroleum based or bio-based. Green biocomposites can be produced using both biobased fibers and polymers. Incompatibility between the hydrophilic biofibers and hydrophobic polymer matrix can cause performance failure of resulting biocomposites. Diverse efforts have focused on the modification of biofibers in order to improve the performances of biocomposites. “Grafting” copolymerization strategy can render the advantages of biofiber and impart polymer properties onto it and the performance of biocomposites can be tuned through changing grafting parameters. This review presents a short overview of various “grafting” methods which can be directly or potentially employed to enhance the interaction between biofibers and a polymer matrix for biocomposites. Major grafting techniques, including ring opening polymerization, grafting via coupling agent and free radical induced grafting, have been discussed. Improved properties such as mechanical, thermal, and water resistance have provided grafted biocomposites with new opportunities for applications in specific industries.

  19. Carbon nanotube grafted with polyalcohol and its influence on the thermal conductivity of phase change material

    International Nuclear Information System (INIS)

    Li, Min; Chen, Meirong; Wu, Zhishen; Liu, Jianxun

    2014-01-01

    Highlights: • CNTs are grafted with polyhydric alcohols. • The grafted CNTs are well dispersed. • The graft ratio of CNTs-C8, CNTs-C14 and CNTs-C18 is 11%, 32% and 38%. • The thermal conductivities of CNTs/paraffin are increased through graft treatment. • The carbon number of polyalcohol has influence on thermal conductivity. - Abstract: Carbon nanotubes (CNTs) were grafted with polyhydric alcohols (octanol, tetradecyl alchohol and stearyl alcohol) after acidification. The composite phase change materials (PCMs) were prepared with grafted CNTs and paraffin. The grafted CNTs were characterized with Transmission Electron Micrograph (TEM), X-ray Diffractometer (XRD), Fourier Transform Infrared Spectroscopy (FTIR) and Thermogravimetric analyzer (TG). Hot disk method was employed to measure the thermal conductivity of composite PCMs. The results showed that polyhydric alcohols were grafted onto CNTs. The graft ratio was 38% for the CNTs grafted with stearyl alcohol. The grafted CNTs were shorter than CNTs and the dispersibility of grafted CNTs was better than that of CNTs. The thermal conductivity of grafted CNTs/paraffin composite PCMs was higher than that of pristine CNTs/paraffin composite PCMs

  20. Radiation-induced grafting of sweet sorghum stalk for copper(II) removal from aqueous solution

    International Nuclear Information System (INIS)

    Dong, Jing; Hu, Jun; Wang, Jianlong

    2013-01-01

    Highlights: • Radiation-induced grafting was used to modify the stalk. • Cellulose, hemicellulose and lignin participated in grafting reaction. • Both the structure and composition of stalk had influence on grafting. • The sorption capacity of the grafted stalk increased about five times. -- Abstract: The influence of main components (cellulose, hemicellulose and lignin) of the sweet sorghum stalk on radiation-induced grafting reaction and adsorption of copper from aqueous solution was investigated. Sweet sorghum stalk was grafted with acrylic acid induced by γ-irradiation. The results showed that the grafted stalk contained 1.6 mmol/g carboxyl groups, and its maximal adsorption capacity was 13.32 mg/g. The cellulose, hemicellulose and lignin of the raw materials were confirmed to involve in grafting reaction through comparing the grafting yield and the structure of the grafted materials. Both the structure and the composition of the sweet sorghum stalk had influence on the grafting reaction and adsorption capacity. The adsorption capacity of the grafted sweet sorghum stalk increased about five times, and the adsorption isotherm of the grafted materials conformed to the Langmuir model. The main mechanism for copper adsorption involved in ion exchange

  1. Graft copolymerization of glycidyl methacrylate onto delignified kenaf fibers through pre-irradiation technique

    International Nuclear Information System (INIS)

    Sharif, Jamaliah; Mohamad, Siti Fatahiyah; Fatimah Othman, Nor Azilah; Bakaruddin, Nurul Azra; Osman, Hasnul Nizam; Güven, Olgun

    2013-01-01

    Glycidyl methacrylate grafted kenaf (GMA-g-Kenaf) was prepared by pre-irradiation grafting technique. Kenaf fibers were treated with different concentration of sodium chlorite solution before used as trunk polymer. Treated kenaf fibers were irradiated by electron beam followed by grafting reaction in GMA/water emulsion system. The degree of grafting was determined as a function of absorbed dose, reaction time, reaction temperature and concentration of monomer. The results showed that the lignin content was decreased from 14.3% to as low as 3.3% with the increased of sodium chlorite concentration. This was evidenced by SEM pictures which show the surface of treated kenaf fibers was cleaner and smoother compared to that of untreated one. The degree of grafting increased with the increase of absorbed dose, reaction temperature, reaction time and monomer concentration as well as with decreasing lignin content. Formation of graft copolymer was confirmed with SEM, FTIR analysis. The structural investigation by XRD showed that degree of crystallinity of graft copolymers decreased with the increase in degree of grafting. - Highlights: • We used kenaf fibers for radiation induce graft copolymerization with GMA. • Kenaf fibers was treated to remove lignin in order to increase grafting yield. • Treated kenaf fibers were graft copolymerize through preirradiation technique. • Optimum conditions for graft copolymerization of kenaf fibers were established. • Formation of graft copolymer is also confirmed with SEM, FTIR and XRD

  2. Studies on the properties of poly (ethylene oxide) R-150 hydrogel films formed by irradiation graft

    International Nuclear Information System (INIS)

    Yang Zhanshan; Zhu Nankang; Yang Shuqin; Qiang Yizhong

    1999-01-01

    In order to improve the mechanical properties of poly (ethylene oxide) (PEO) hydrogel film was used as wound dressing. The chemical and physical properties of the PEO R-150 graft hydrogel film formed by blends of electron beam irradiated-PEO R-150 and poly(vinyl alcohol) (PVA) were studied. The experimental results showed that the crosslinking densities of the PEO R-150 graft hydrogel increased along with the increasing of the irradiation doses and decreased with the increasing of the blend concentrations. While the PVA graft proportions did not produce obvious effects on the crosslinking density of the graft hydrogel. The crosslinking density of the graft hydrogel were obviously lower than that of the pure PVA hydrogel. The equilibrium water content of the graft hydrogel decrease as the irradiation dose and the PVA graft proportion increased; but they increased as the blend concentration increased. The equilibrium water content of the graft hydrogel was obviously higher than those of the pure PVA hydrogel. The hardness of the PVA hydrogel film increased with the irradiation dose. The hardness of the graft hydrogel decreased with the blend concentration, whereas it increased with the PVA graft proportion. The results suggest the PVA produces a main effect on the crosslinking density of the graft hydrogel, the PEO R-150 produces a main effect on the equilibrium water content of the graft hydrogel, and the both polymers have double effects on the hardness of the graft hydrogel

  3. Reconstruction of saddle nose deformity with calvarial bone graft

    International Nuclear Information System (INIS)

    Ghiasi, S.

    2013-01-01

    Objective: To evaluate the efficacy of calvarial bone in the reconstruction of saddle nose deformity. Methods: The cross-sectional study was conducted at the Plastic Surgery Unit of Imam Reza Hospital, Tabriz University of Medical Sciences, Iran, from July 2004 to October 2009. It comprised 19 patients who underwent saddle nose deformity reconstruction with calvarial bone graft. All patients were operated upon under general anaesthesia. They were followed up periodically. Results: The patients followed up for 25 to 61 months for an average period of 39.2+-4.3 months. In 14 (74%) patients the result of the surgical intervention was excellent, while in 5 (26%) it was acceptable. All patients were satisfied and there was not displacement, absorption, distortion or infection of the graft. Conclusion: Calvarial bone graft is a viable option for the reconstruction of saddle nose deformity, especially in severe cases. (author)

  4. [Kidney graft loss as a result of coagulation disorders].

    Science.gov (United States)

    Kulik, Agnieszka

    2012-04-01

    Renal transplantation is a method of choice in the treatment of endstage kidney insufficiency resulting in improved survival and better quality of life. Advances in immunosuppresive therapy, diagnosis and treatment of infective complications, studies on ischemic injury of transplanted organ and preservation show constant improvement in terms of short and long-term results. Early kidney graft loss resulting from thrombotic complications is rare and still challenging for transplantologists. Renal vein thrombosis is responsible for 2-7% cases of early graft loss. Selecting a subset of patients threatened with thromboembolic complications will allow for starting adequate prophylaxis, or early treatment preventing from complications including graft loss. In this paper we tried to summarize the current state of knowledge regarding venous and arterial thrombosis after renal transplantation.

  5. Separation Functional Fibers by Radiation Induced Graft Polymerization and Application

    International Nuclear Information System (INIS)

    Fujiwara, K.

    2006-01-01

    1. Method for manufacturing process of separation functional fiber.Radiation graft machine(Photo 1) was developed by EBARA and Japan atomic energy research institute (JAERI) in 1999. Long Sheet of 1.5 m width is continuously grafted using Electron Beam EB (300 keV).The control of oxygen concentration in the monomer impregnation zone and reactor is very important. Usually 100% or more grafting ratio is obtained under irradiation dose of 150 kGy,.2. Application; Chemical filter (for clean room), Electric de-ionization(for pure water), Mask(for influenza) shows application of functional fiber. In clean room of semiconductor factory, ionic contaminants, such as ammonia gas(NH 3 ) should be removed to extremely low concentration level. Chemical filter (Photo 2) with ion-exchange fabric is widely used

  6. Cells adhesion and growth on gold nanoparticle grafted glass

    Energy Technology Data Exchange (ETDEWEB)

    Novotna, Zdenka, E-mail: zdenka1.novotna@vscht.cz [Department of Solid State Engineering, Institute of Chemical Technology Prague, 166 28 Prague (Czech Republic); Reznickova, Alena; Kvitek, Ondrej; Kasalkova, Nikola Slepickova [Department of Solid State Engineering, Institute of Chemical Technology Prague, 166 28 Prague (Czech Republic); Kolska, Zdenka [Faculty of Science, J. E. Purkyně University, Ústí nad Labem (Czech Republic); Svorcik, Vaclav [Department of Solid State Engineering, Institute of Chemical Technology Prague, 166 28 Prague (Czech Republic)

    2014-07-01

    The surface of glass substrate was plasma treated, coated by gold nano-structures and subsequently grafted with nanoparticles. The samples were plasma treated, sputtered with Au nanostructures which was followed by grafting with biphenyl-4,4'-dithiol (BPD) and then gold nanoparticles. The wettability, optical and chemical properties and surface morphology were studied. The adhesion and proliferation of vascular smooth muscle cells (VSMCs) on the samples were investigated in-vitro as well. Grafting of gold nanoparticles with the dithiol increases the UV–vis absorbance, the surface becomes more hydrophobic, rougher and more rugged compared to pristine, sputtered and only dithiol treated surface. Gold nano-particles bound over dithiol and Au nanostructures cause better cell proliferation than purely BPD treated or pristine glass.

  7. [Surface grafting modification and stabilization of Kevlar fiber].

    Science.gov (United States)

    Zheng, Yu-ying; Fu, Ming-lian; Wang, Can-yao; Wang, Liang-en

    2005-11-01

    Chemical disposal was used to bring the activity group onto the surface of Kevlar fiber for the purpose of surface grafting modification. The interfacial constitution of the grafting of toluene-2,4-diisocyanate (TDI) onto Kevlar fiber was determined by Fourier transform infrared spectroscopy. In the mean time, hexyl-lactam stabilization and poly-glycol (400, PEG) stabilization on the grafted product were also studied. The effects of different nTDI:nPEG ratios on the production's interfacial constitution was analysed. It is concluded that the stabilization took place on the surface. The intensity of the bands relented at about 3300 cm(-1) and was reinforced at about 1700-1720 cm(-1) when the ratio of nTDI:nPEG = 1:3, but when the ratio is 1:1 and 1:2, the bands at about 3 300 and 1700-1720 cm(-1) are almost the same.

  8. Au-nanoparticles grafted on plasma treated PE

    International Nuclear Information System (INIS)

    Svorcik, V.; Chaloupka, A.; Rezanka, P.; Slepicka, P.; Kolska, Z.; Kasalkova, N.; Hubacek, T.; Siegel, J.

    2010-01-01

    Polyethylene (PE) surface was treated with Ar plasma. Activated surface was grafted from methanol solution of 1,2-ethanedithiol. Then the sample was immersed into freshly prepared colloid solution of Au-nanoparticles. Finally Au layer was sputtered on the samples. Properties of the modified PE were studied using various methods: AFM, EPR, RBS and nanoindentation. It was shown that the plasma treatment results in degradation of polymer chain (AFM) and creation of free radicals by EPR. After grafting with dithiol, the concentration of free radicals declines. The presence of Au and S in the surface layer after the coating with Au-nanoparticles was proved by RBS. Plasma treatment changes PE surface morphology and increases surface roughness, too. Another significant change in surface morphology and roughness was observed after deposition of Au-nanoparticles. Nanoindentation measurements show that the grafting with Au-nanoparticles increases adhesion of subsequently sputtered Au layer.

  9. Assessment of Competence in EVAR Stent Graft Sizing and Selection

    DEFF Research Database (Denmark)

    Strøm, M; Lönn, L.; Bech, B.

    2017-01-01

    Objectives and background: The aims of this study were to develop a test of competence in endovascular aortic repair (EVAR) stent graft sizing and selection; to examine the test for evidence of validity; and to explore the experience required for the task. Methods: The test was developed based...... on a literature review resulting in 22 anatomical assessment points and a graft selection. Validity evidence was explored in an international cross sectional study. Twenty-two consultants with varying levels of experience in the field (novices, intermediates, and experts) were presented with computed tomography...... angiography of the aortic vessels from three patients. Test scores were based on summed z-scores using the anatomical measurements and graft choices of the experts as a reference. A proficiency score was established using the contrasting groups standard setting method. Results: The assessment was shown...

  10. Surface grafted polymer brushes: potential applications in dengue biosensors

    International Nuclear Information System (INIS)

    Baratela, Fernando Jose Costa; Higa, Olga Zazuco; Faria, Henrique Antonio Mendonca de; Queiroz, Alvaro Antonio Alencar de

    2013-01-01

    A polymer brush membrane-based ultrasensitive biosensor for dengue diagnosis was constructed using poly(hydroxyethyl methacrylate) (PHEMA) brushes immobilized onto low density polyethylene (LDPE) films. LDPE surface films were initially modified by Ar + ion irradiation to activate the polymer surface. Subsequently, graft polymerization of 2-hydroxyethyl methacrylate onto the activated LDPE surface was carried out under aqueous conditions to create patterned polymer brushes of PHEMA. The grafted PHEMA brushes were characterized by Fourier transform-infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and contact angle analysis. The SEM observations showed that selective surface activation with Ar+ implantation and graft polymerization on the selectively activated surface had occurred. The PHEMA brushes were electrically characterized in the presence of concentrations of human immunoglobulin (IgG). The proposed amperometric biosensor was successfully used for determination of IgG in physiologic samples with excellent responses. (author)

  11. Surface grafted polymer brushes: potential applications in dengue biosensors

    Energy Technology Data Exchange (ETDEWEB)

    Baratela, Fernando Jose Costa; Higa, Olga Zazuco, E-mail: ozahiga@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Faria, Henrique Antonio Mendonca de; Queiroz, Alvaro Antonio Alencar de, E-mail: alencar@unifei.edu.br [Universidade Federal de Itajuba (UNIFEI), Itajuba, MG (Brazil). Instituto de Fisica e Quimica

    2013-07-01

    A polymer brush membrane-based ultrasensitive biosensor for dengue diagnosis was constructed using poly(hydroxyethyl methacrylate) (PHEMA) brushes immobilized onto low density polyethylene (LDPE) films. LDPE surface films were initially modified by Ar{sup +} ion irradiation to activate the polymer surface. Subsequently, graft polymerization of 2-hydroxyethyl methacrylate onto the activated LDPE surface was carried out under aqueous conditions to create patterned polymer brushes of PHEMA. The grafted PHEMA brushes were characterized by Fourier transform-infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and contact angle analysis. The SEM observations showed that selective surface activation with Ar+ implantation and graft polymerization on the selectively activated surface had occurred. The PHEMA brushes were electrically characterized in the presence of concentrations of human immunoglobulin (IgG). The proposed amperometric biosensor was successfully used for determination of IgG in physiologic samples with excellent responses. (author)

  12. Aspirin decreases platelet uptake on Dacron vascular grafts in baboons

    International Nuclear Information System (INIS)

    Mackey, W.C.; Connolly, R.J.; Callow, A.D.

    1984-01-01

    The influence of a single dose of aspirin (5.4-7.4 mg/kg) on platelet uptake on 4-mm Dacron interposition grafts was studied in a baboon model using gamma camera scanning for 111-Indium labeled platelets. In vitro assessment of platelet function after aspirin administration revealed that in the baboon, as in the human, aspirin abolished arachidonic acid-induced platelet aggregation, prolonged the lag time between exposure to collagen and aggregation, and decreased plasma thromboxane B2 levels. Aspirin also prolonged the template bleeding time. Scans for 111-Indium labeled platelets revealed that pretreatment with a single dose of aspirin decreased platelet uptake on 4-mm Dacron carotid interposition grafts. This decrease in platelet uptake was associated with a significant improvement in 2-hour graft patency and with a trend toward improved 2-week patency

  13. Epidermal grafting versus split-thickness skin grafting for wound healing (EPIGRAAFT): study protocol for a randomised controlled trial.

    Science.gov (United States)

    Kanapathy, Muholan; Hachach-Haram, Nadine; Bystrzonowski, Nicola; Harding, Keith; Mosahebi, Afshin; Richards, Toby

    2016-05-17

    Split-thickness skin grafting (SSG) is an important modality for wound closure. However, the donor site becomes a second, often painful wound, which may take more time to heal than the graft site itself and holds the risk of infection and scarring. Epidermal grafting (EG) is an alternative method of autologous skin grafting that harvests only the epidermal layer of the skin by applying continuous negative pressure on the normal skin to raise blisters. This procedure has minimal donor site morbidity and is relatively pain-free, allowing autologous skin grafting in an outpatient setting. We plan to compare EG to SSG and to further investigate the cellular mechanism by which each technique achieves wound healing. EPIGRAAFT is a multicentre, randomised, controlled trial that compares the efficacy and wound-healing mechanism of EG with SSG for wound healing. The primary outcome measures are the proportion of wounds healed in 6 weeks and the donor site healing time. The secondary outcome measures include the mean time for complete wound healing, pain score, patient satisfaction, health care utilisation, cost analysis, and incidence of adverse events. This study is expected to define the efficacy of EG and promote further understanding of the mechanism of wound healing by EG compared to SSG. The results of this study can be used to inform the current best practise for wound care. Clinicaltrials.gov identifier, NCT02535481 . Registered on 11 August 2015.

  14. PVDF multifilament yarns grafted with polystyrene induced by γ-irradiation: Influence of the grafting parameters on the mechanical properties

    International Nuclear Information System (INIS)

    Marmey, P.; Porte, M.C.; Baquey, Ch.

    2003-01-01

    The development of alternative prosthetic materials for cardiovascular applications has found growing interest due to the failure to date to be able to implement functional patent small diameter vascular grafts (diameter <5 mm). For instance, the successful implantation of small diameter polyester (PET) and expanded polytetrafluoroethylene (PTFEe) vascular grafts has not been achieved in humans. Our strategy is to work with a new multifilament yarns biomaterial, produced from polyvinylidene fluoride (PVDF), which shows suitable mechanical properties, such as a lower tensile modulus than PET and PTFEe. The required biological properties sought for (i.e. low thrombogenicity) could be achieved by 'heparin-like' surface modification treatments in order to modify the thrombogenicity levels of the polymeric materials [Ann. Biomed. Eng. 7 (1979) 429]. A four step method is necessary to achieve this 'heparin-like' surface transformation [J. Biomed. Mater. Res. 52 (2000) 119]. The first step consists in grafting polystyrene onto the PVDF surface by γ irradiation. The purpose of this study was to evaluate the influence of grafting parameters on the mechanical properties: (i) γ-ray irradiation time and (ii) grafting time of styrene monomers, which polymerize and form polystyrene bound to the PVDF surface

  15. Paediatric fingertip composite grafts: Do they all go black?

    Science.gov (United States)

    Murphy, Adrian D; Keating, Cameron P; Penington, Anthony; McCombe, David; Coombs, Chris J

    2017-02-01

    Fingertip injuries are amongst the most frequently seen hand injuries in the paediatric population. The present study evaluated the composite graft survival rate in distal digital amputations with respect to injury type, amputation level and time to surgery. We performed a retrospective review of patients who underwent composite grafting of fingertip injuries over an 11-year period at a paediatric hospital. All children who underwent non-vascularized replantation of amputated fingertips were included. Patients were excluded if they failed to attend at least one follow-up appointment. Demographic information was recorded. The nature and level of injury and time to surgery was also recorded. Graft viability was characterized as no take, partial take, or complete take. The number of secondary procedures and number and duration of follow-up appointments were recorded. A total of 105 patients underwent fingertip composite grafting, of whom 96 were suitable for inclusion in this study. The median age was 2.4 years (0-16 years); there were 48 boys (46%) and 57 girls (54%). Thirty-one patients had no graft take (32%), 50 patients had partial take (52%) and 15 patients had complete take (16%). Only two patients underwent secondary revision (2%). The median number of follow-up appointments was 4, and the mean follow-up time was 68 days. Time to surgery or level of amputation did not have a statistically significant influence on outcome. Over two-thirds of composite grafts in children showed some degree of take, albeit partially in the majority. Morbidity was low, and most children did not require further surgery. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  16. Hollow fiber membrane lumen modified by polyzwitterionic grafting

    KAUST Repository

    Le, Ngoc Lieu

    2016-08-24

    In this study, we demonstrate an effective way to modify the lumen of polyetherimide hollow fibers by grafting zwitterionic poly(sulfobetaine) to increase the membrane resistance to fouling. Surface-selective grafting of the protective hydrogel layers has been achieved in a facile two-step process. The first step is the adsorption of a macromolecular redox co-initiator on the lumen-side surface of the membrane, which in the second step, after flushing the lumen of the membrane with a solution comprising monomers and a complementary redox initiator, triggers the in situ cross-linking copolymerization at room temperature. The success of grafting reaction has been verified by the surface elemental analyses using X-ray photoelectron spectroscopy (XPS) and the surface charge evaluation using zeta potential measurements. The hydrophilicity of the grafted porous substrate is improved as indicated by the change of contact angle value from 44° to 30°, due to the hydration layer on the surface produced by the zwitterionic poly(sulfobetaine). Compared to the pristine polyetherimide (PEI) substrate, the poly(sulfobetaine) grafted substrates exhibit high fouling resistance against bovine serum albumin (BSA) adsorption, E. coli attachment and cell growth on the surface. Fouling minimization in the lumen is important for the use of hollow fibers in different processes. For instance, it is needed to preserve power density of pressure-retarded osmosis (PRO). In high-pressure PRO tests, a control membrane based on PEI with an external polyamide selective layer was seriously fouled by BSA, leading to a high water flux drop of 37%. In comparison, the analogous membrane, whose lumen was modified with poly(sulfobetaine), not only had a less water flux decline but also had better flux recovery, up to 87% after cleaning and hydraulic pressure impulsion. Clearly, grafting PRO hollow fiber membranes with zwitterionic polymeric hydrogels as a protective layer potentially sustains PRO

  17. Sarpogrelate hydrochloride reduced intimal hyperplasia in experimental rabbit vein graft.

    Science.gov (United States)

    Kodama, Akio; Komori, Kimihiro; Hattori, Keisuke; Yamanouchi, Dai; Kajikuri, Junko; Itoh, Takeo

    2009-05-01

    The selective 5-HT(2A) receptor antagonist sarpogrelate has been clinically used for treatment in atherosclerotic diseases. However, it remains unknown whether administration of sarpogrelate inhibits intimal hyperplasia seen in autologous vein grafts. Therefore, we sought to clarify this question using an experimental rabbit vein graft model. Male rabbits were divided into two groups: a control group and a sarpogrelate-treated group. The jugular vein was interposed in the carotid artery in reversed fashion for 4 weeks and intimal hyperplasia of the grafted vein was measured (n = 8, in each group). Acetylcholine (ACh)-induced endothelium-dependent relaxation was tested by precontraction with prostaglandin F(2alpha) (PGF(2alpha), 5 muM) (n = 5, in each). endothelial nitric oxide synthase (eNOS) protein expression and superoxide production of these veins were also assessed. The suppression of intimal hyperplasia was significantly greater in the sarpogrelate-treated group than in the control group. ACh induced an endothelium-dependent relaxation in the sarpogrelate-treated group (but not in the control group). In endothelium-intact strips from the sarpogrelate-treated group, the nitric oxide (NO) synthase inhibitor nitroarginine enhanced the PGF(2alpha)-induced contraction and blocked the ACh-induced relaxation. Immunoreactive eNOS protein expression was similar between the two groups but superoxide production (estimated from ethidium fluorescence) in endothelial cells was significantly smaller in the sarpogrelate-treated group. The present results indicate that in vivo blockade of 5-HT(2A) receptors leads to an inhibition of intimal hyperplasia in rabbit vein graft. It is suggested that an increased function of endothelium-derived NO through a reduction in endothelial superoxide production may be a possible underlying mechanism for this. These novel findings support the clinical usefulness of sarpogrelate for preventing intimal hyperplasia in vein graft after bypass

  18. The Effect of Smoking on Facial Fat Grafting Surgery.

    Science.gov (United States)

    Özalp, Burhan; Çakmakoğlu, Çağri

    2017-03-01

    Facial fat grafting has been increasingly performed to create a more youthful face. Cigarette smoking might have potential harmful effects on fat graft survival. The aim of this study was to evaluate the effects of cigarette smoking on facial lipofilling.Eighteen smoker patients (13 females and 5 males) with a mean age of 37.4 years (range: 21-53 years) who underwent facial lipofilling were enrolled in this retrospective study. The patients were followed up for an average of 19.3 months (range: 14-32 months). The fat-graft survival rate, degree of skin improvement, and presence and severity of surgical complications (fat necrosis, oil cysts, and infection) were evaluated. A 10-point Likert scale was used to assess patient satisfaction with facial fat grafting surgery.The mean injected fat volume was 42 mL (range: 30-80 mL). Clinical and photographic evaluation by the surgical team led to an estimation of 40% for the mean fat survival rate. Four instances of fat necrosis, 2 oil cysts, and 1 infection were diagnosed and treated conservatively. Five patients underwent a second fat grafting surgical procedure; 3 of these had a third fat grafting surgery to obtain the desired facial fullness. Improvement of skin quality was better during the first months after surgery, but not long standing. Overall patient satisfaction in terms of aesthetic appearance, facial fullness, and rejuvenation was 74%.Although cigarette smoking causes low fat survival rates and impairs the improvement of skin quality, successful results can be obtained with facial lipofilling in the smokers.

  19. Experience with chest wall arteriovenous grafts in hemodialysis patients.

    Science.gov (United States)

    Liechty, Joseph M; Fisher, Tammy; Davis, Wilson; Oglesby, Wes C; Bennett, Monica; Grimsley, Brad; Shutze, William

    2015-01-01

    Maintaining long-term hemodialysis access in end-stage renal disease patients presents a serious challenge to surgeons. Over time, patients' remaining access sites diminish while complications and comorbidities simultaneously multiply; often resulting in the use of permanent tunneled catheters, which have a well-known high rate of complications and short-term usefulness. In this study, we report the results of a dialysis graft based on the axillary artery and ipsilateral axillary vein and tunneled in the subcutaneous tissues of the chest. We identified patients who had a chest wall arteriovenous graft (CWAVG) placed at our institution between May 2007 and December 2012. After institutional review board approval, the patients were retrospectively and then prospectively identified and followed for 2 years to document the performance, required maintenance, and complications of the graft. Sixty-seven grafts in 67 patients were reviewed, representing 0.56% of our 1,192 total dialysis access creations during the study period. The average patient was 55-year-old with an average history of 3.97 explicitly documented prior accesses. Sixty interventions were performed postoperatively including 32 for thrombosis and 28 for venous stenosis. Six documented graft infections occurred (9%). Three minor wound complications occurred, but the graft was preserved. Notably, no patient developed symptoms of steal syndrome. The primary and secondary patency rates at 1 and 2 years were 69.5% and 36.9% and 81.6% and 57.6%, respectively. Twenty-three of the 67 patients died in the 2-year follow-up period (34%). CWAVGs are useful and appropriate for patients with difficult upper extremity access. The patency rates for this "exotic" procedure are at least equivalent to other upper extremity grafts. The infection rate is lower than that for femoral grafts or tunneled catheters, and there is no risk of steal syndrome. CWAVGs can even be considered for primary use in patients who have

  20. Reconstruction of Thoracic Wall Defect with Polytetrafluoroethylene Graft

    Directory of Open Access Journals (Sweden)

    Erkan Akar

    2014-03-01

    The most common causes of major thoracic traumas are stabwounds, traffic accidents and gunshot wounds. Thoracic wall defects developing due to these injuries should be repaired if they lead to paradoxal respiration. We repaired the thoracic wall defect of the 25-year-old male patient who was admitted to our clinic with gunshot wound with Polytetrafluoroethylene graft as expansion dysfunction and paradoxal respiration developed. No complications developed and he was discharged with recovery.  In conclusion, Polytetrafluoroethylene graft is a good reconstruction tool at present because it prevents paradoxal respiration successfully, applied easily and cosmetic. 

  1. Structural Transitions of Solvent-Free Oligomer-Grafted Nanoparticles

    KAUST Repository

    Chremos, Alexandros

    2011-09-01

    Novel structural transitions of solvent-free oligomer-grafted nanoparticles are investigated by using molecular dynamics simulations of a coarse-grained bead-spring model. Variations in core size and grafting density lead to self-assembly of the nanoparticles into a variety of distinct structures. At the boundaries between different structures, the nanoparticle systems undergo thermoreversible transitions. This structural behavior, which has not been previously reported, deviates significantly from that of simple liquids. The reversible nature of these transitions in solvent-free conditions offers new ways to control self-assembly of nanoparticles at experimentally accessible conditions. © 2011 American Physical Society.

  2. Considerations in setting up and planning a graft processing facility.

    Science.gov (United States)

    Koh, Mickey B C

    2017-12-01

    The graft processing facility forms one of the core components of a clinical haematopoietic stem cell transplant program. The quality of a graft is instrumental in leading to consistent and reproducible outcomes of engraftment and other parameters. As such, meticulous planning and consideration is required and will include core elements including physical design and clinical correlates. The successful running of such a facility depends on an overarching quality program and adherence to local and international regulatory guidelines. Copyright © 2017 King Faisal Specialist Hospital & Research Centre. Published by Elsevier B.V. All rights reserved.

  3. 'Like new': plastic wastes regeneration by radiation induced grafting

    International Nuclear Information System (INIS)

    Laizier, J.; Gaussens, G.; Lemaire, F.

    1978-01-01

    The reclaiming and the recycling of plastic wastes is made especially difficult when those wastes are a mixture of various plastics; this is due to the incompatibility of the polymers. The radiation induced grafting allows to overcome this incompatibility. Results are given which shows that, for various mixtures of reclaimed polyethylene, PVC and polystyrene, an improvement of the properties of the processed blends is obtained by grafting the mixtures of wastes by a suitable polymer; the obtained properties of those regenerated plastic blends are enough attractive from the technical point of view to open a market to those products with a reasonable economical value [fr

  4. VUV modification promotes endothelial cell proliferation on PTFE vascular grafts

    Science.gov (United States)

    Cezeaux, J. L.; Romoser, C. E.; Benson, R. S.; Buck, C. K.; Sackman, J. E.

    1998-05-01

    Small diameter (⩽6 mm ID ) synthetic vascular grafts, used as lower-limb vessel replacements in patients without suitable autologous saphenous veins, have a failure rate of 53% after 4 yr. Graft failure is due to thrombosis and intimal hyperplasia, an increase in smooth muscle cells in the lumen of the vessel which leads to progressive closing and ultimate occlusion of the vessel. In an effort to increase patency rates of synthetic grafts, investigators have seeded vascular grafts with endothelial cells prior to implantation in an attempt to control both thrombosis and smooth muscle proliferation. This technique has been successful for the development of an endothelial monolayer in animal trials, but has met with limited success in humans. The hydrophobicity, low surface energy, and weak electrical charge of expanded polytetrafluoroethylene (ePTFE) provides conditions which are not optimal for endothelial cell attachment. The purpose of this study is to evaluate the effect of vacuum ultraviolet (VUV) modification of ePTFE on endothelial cell adhesion and proliferation. Pieces of ePTFE graft material were exposed to 10, 20 or 40 W VUV radiation for 10, 20 or 40 min using a UV excimer lamp. Prior to cell adhesion and proliferation experiments, the grafts pieces were autoclaved and cut into pledgets. Half of the pledgets were precoated with fibronectin ( 20 μg/ml). Cell adhesion was measured by seeding 3H-thymidine labeled human umbilical vein endothelial cells (HUVEC) onto the pledgets for 60 min. The pledgets were then washed and the remaining radioactivity assayed using scintillation counting. For the cell proliferation experiments, pledgets were seeded with unlabeled HUVEC which were allowed to adhere to the graft material for 18 h. The cells were then exposed to 3H-thymidine ( 1 μCi/ml) for approximately 48 h and then washed to remove any unincorporated 3H-thymidine. Incorporation of 3H-thymidine was measured using scintillation counting. Four replicate

  5. Capturing of staphylococcus aureus onto an interface containing graft chains

    International Nuclear Information System (INIS)

    Lee, W.; Furusaki, Shintaro; Saito, Kyoichi; Sugo, Takanobu; Makuuchi, Keizo.

    1995-01-01

    A microbial-cell-capturing material was prepared by radiation-induced grafting of glycidyl methacrylate onto a polyethylene-based fiber before the introduction of diethylamine. The prepared fiber was tested against a Staphylococcus aureus and Escherichia coli solution. The results showed that the grafted-type fiber had a capturing rate constant 1000-fold higher than the commercial crosslinked-type bead for S. aureus and that an activation energy of 39 kJ/mol was obtained for the microbial-cell-capturing action. (author)

  6. Characterization of the grafting copolymer EPDM-SAN

    International Nuclear Information System (INIS)

    Turchette, Renato; Felisberti, Maria Isabel

    2001-01-01

    This work aims the characterization of the grafting copolymer EPDM-SAN. This copolymer presents a fraction of free SAN chains, which was extracted by solubilization in chloroform followed of precipitation of the grafting copolymer EPDM-g-SAN in acetone. The EPDM-SAN and EPDM-g-SAN were characterized by 13 C NMR, DSC, TGA and SEM. EPDM-SAN contain 23 wt% of free SAN and 77 wt% of EPDM-g-SAN. Both materials are heterogeneous and the thermal and thermo-oxidative degradation are independent of the composition. (author)

  7. Punch Grafting In Chronic Stable Vitiligo : A Preliminary Report

    Directory of Open Access Journals (Sweden)

    Sirka C. S

    1997-01-01

    Full Text Available Eleven patients of stable vitiligo (7 segmental, 2 focal, 2 contact depigmentation having localized lesions were treated with autologous punch skin grafts. The cosmetic improvement at 5th month was good in 3, fair in 7 and poor in 1. However, at 7th month the improvement was excellent in 4, good in 6 and poor in 1. Complications in the form of variegated colour â€" 9 patients, cobblestoning â€" 8 patients, depigmentation â€"1 patient and graft loss in 1 patient were noted in this study. The role of adjuvant therapy (topical steroid and topical psoralen is highlighted.

  8. LONG TERM EVOLUTION OF BONE RECONSTRUCTION WITH BONE GRAFT SUBSTITUTES

    Directory of Open Access Journals (Sweden)

    O. V. Martynenko

    2017-06-01

    Full Text Available The review involves clinical and experimental data, constitutive modeling, and computational investigations towards an understanding on how mechanical cyclic loads for long periods of time affect damage evolution in a reconstructed bone, as well as, lifetime reduction of bone graft substitutes after advanced core decompression. The outcome of the integrated model discussed in this paper will be how damage growth in femur after advanced core decompression subjected to mechanical cyclic loading under creep and fatigue conditions may be controlled in order to optimize design and processing of bone graft substitutes, and extend lifetime of bone substitutes.

  9. Corneal blindness and current major treatment concern-graft scarcity

    Directory of Open Access Journals (Sweden)

    Kah Hie Wong

    2017-07-01

    Full Text Available According to World Health Organization, the global prevalence of blindness in 2010 was 39 million people, among which 4% were due to corneal opacities. Often, the sole resort for visual restoration of patients with damaged corneas is corneal transplantation. However, despite rapid developments of surgical techniques, instrumentations and immunosuppressive agents, corneal blindness remains a prevalent global health issue. This is largely due to the scarcity of good quality corneal grafts. In this review, the causes of corneal blindness, its major treatment options, and the major contributory factors of corneal graft scarcity with potential solutions are discussed.

  10. Reconstruction of the bulbar urethra using dorsal onlay buccal mucosal grafts: New concepts and surgical tricks

    Directory of Open Access Journals (Sweden)

    Guido Barbagli

    2006-01-01

    Full Text Available Buccal mucosa onlay graft urethroplasty represents one of the most widespread methods for the repair of strictures in the bulbar urethra, because of its thick and highly vascular spongiosum tissue. Recently the location of the patch has become a contentious issue, since we described our original techniques of dorsal onlay graft urethroplasty. The design rationale for this approach was based on the concept that the corporeal body remains a healthy host for receiving a free transplanted tissues. Moreover, graft fixation onto a defined surface may decrease graft shrinkage and sacculation. The success rate using buccal mucosa grafts for the repair of bulbar urethral strictures has generally been high with dorsal or ventral onlay grafts or using an augmented roof-strip anastomotic urethroplasty. We describe here the fundamental concepts of the bulbar urethra reconstruction using buccal mucosal grafts, presenting a new surgical technique of dorsal onlay buccal mucosa graft urethroplasty using fibrin glue.

  11. Secondary bone grafting for alveolar cleft in children with cleft lip or cleft lip and palate

    NARCIS (Netherlands)

    Guo, J.; Li, C.; Zhang, Q.; Wu, G.; Deacon, S.A.; Chen, J.; Hu, H.; Zou, S.; Ye, Q.

    2011-01-01

    BACKGROUND: Secondary alveolar bone grafting has been widely used to reconstruct alveolar cleft. However, there is still some controversy. OBJECTIVES: To compare the effectiveness and safety of different secondary bone grafting methods. SEARCH STRATEGY: The final electronic and handsearches were

  12. Use of non-vascularized autologous fibula strut graft in the treatment ...

    African Journals Online (AJOL)

    Orthopedic surgeons in developed countries have the option of choosing vascularized bone transfers, bone transport, allogenic bone grafts, bone graft substitutes ... tissue envelope assessment, neurological examination, and debridement under general anesthesia with fracture stabilization with external fixators or casts.

  13. Dysphagia after an L-shaped reconstruction technique of the free jejunum graft.

    NARCIS (Netherlands)

    Keereweer, S.; Sewnaik, A.; Kerrebijn, J.D.; Meeuwis, C.A.; Tilanus, H.W.; Wilt, J.H.W. de

    2010-01-01

    BACKGROUND: The free jejunum graft is a well-established reconstruction technique after total laryngopharyngectomy. However, besides necrosis of the jejunum graft, the two most important complications are pharyngocutaneous fistula formation and dysphagia due to stricture formation. OBJECTIVES: This

  14. Bone graft substitutes and bone morphogenetic proteins for osteoporotic fractures: What is the evidence?

    NARCIS (Netherlands)

    E.M.M. van Lieshout (Esther); V. Alt (Volker)

    2016-01-01

    textabstractDespite improvements in implants and surgical techniques, osteoporotic fractures remain challenging to treat. Among other major risk factors, decreased expression of morphogenetic proteins has been identified for impaired fracture healing in osteoporosis. Bone grafts or bone graft

  15. Retransplantation in Late Hepatic Artery Thrombosis: Graft Access and Transplant Outcome

    Directory of Open Access Journals (Sweden)

    Bettina M. Buchholz, MD, FEBS

    2017-08-01

    Conclusions. Inequity in graft access and peritransplant sepsis are fundamental obstacles for successful re-LT in L-HAT. Offering a graft for those in need at the best window of opportunity could facilitate earlier engrafting with improved outcomes.

  16. Laparoscopic diagnosis and treatment of aortic vascular prosthetic graft infections in a porcine model

    DEFF Research Database (Denmark)

    Gao, Hongding; Lund, L; Prag, J

    2008-01-01

    To study the feasibility and efficacy of experimental laparoscopy in the diagnosis of aortic graft infection in pigs.......To study the feasibility and efficacy of experimental laparoscopy in the diagnosis of aortic graft infection in pigs....

  17. Techniques and standards in intraoperative graft verification by transit time flow measurement after coronary artery bypass graft surgery: a critical review.

    Science.gov (United States)

    Niclauss, Lars

    2017-01-01

    Transit time flow measurement (TTFM) is a quality control tool for intraoperative graft evaluation in coronary artery bypass graft (CABG) surgery. A critical review of the literature available using TTFM in CABG surgery is the focus of this article. The main objectives will be to detail precise parameters for flow evaluation, to show limitations of TTFM and to prove its predictive impact on postoperative graft failure rate. Publications listed in the PubMed database were reviewed, searching for intraoperative graft verification in coronary surgery by TTFM, with postoperative imaging follow-up (FU) modality and with a special focus on publications released after European guidelines from 2010. Nine included publications revealed an overall graft failure rate of ∼12%. Mean graft flow had a positive predictive value in the largest study, and cut-offs, of at least 20 ml/min for internal mammary artery (IMA) grafts, therein partially confirming guidelines, and 30-40 ml/min for saphenous venous grafts (SVGs) were proposed. An explicit correlation between graft flow, patency rate and severity of coronary stenosis, by indicating the fractional flow reserve, was found for IMA grafts. Increased pulsatility index and increased systolic reverse flow probably predict worse outcome and may help identifying competitive flow. Diastolic filling, rarely indicated, could not be confirmed as the predictive marker. No significant correlation of TTFM and graft failure rate for radial and other arterial grafts could be found, partially due to the small number of these types of grafts analysed. Larger target vessels and lower postoperative CK-MB levels may predict better graft patency rates. Low sensitivity for TTFM to reliably detect graft failure is certainly a major issue, as found in randomized analyses. However, methodical limitations and varying threshold values for TTFM render a general consensus difficult. Influence of quantity (vessel territory distribution) and quality

  18. Comparison of mesencephalic free-floating tissue culture grafts and cell suspension grafts in the 6-hydroxydopamine-lesioned rat

    DEFF Research Database (Denmark)

    Meyer, Morten; Widmer, H R; Wagner, B

    1998-01-01

    days in culture or directly as dissociated cell suspensions, and compared with regard to neuronal survival and ability to normalize rotational behavior in adult rats with unilateral 6-hydroxydopamine (6-OHDA) lesions. Other lesioned rats received injections of cell-free medium and served as controls...... of grafted dopaminergic neurons and to correlate that with the behavioral effects. Additional cultures and acutely prepared explants were also fixed and stored for histological investigation in order to estimate the loss of dopaminergic neurons in culture and after transplantation. Similar behavioral...... improvements in terms of significant reductions in amphetamine-induced rotations were observed in rats grafted with FFRT cultures (127%) and rats grafted with cell suspensions (122%), while control animals showed no normalization of rotational behavior. At 84 days after transplantation, there were similar...

  19. Synthesis, Characterization and Evaluation of the Transformations in Hibiscus sabdariffa-graft-poly(butyl acrylate

    Directory of Open Access Journals (Sweden)

    B. S. Kaith

    2008-01-01

    Full Text Available Different reaction parameters for the graft copolymerization of butyl acrylate onto Hibiscus sabdariffa fiber were optimized. Graft copolymers thus obtained were subjected to characterization using XRD, TGA, DTA, SEM and FTIR techniques and were evaluated for physio-chemical changes in the behavior. The percentage crystallinity and crystallinity index were found to decrease with increase in grafting while there was reduction in moisture absorption and increase in chemical, thermal resistance of the graft copolymers.

  20. Transit Time Flowmetry in Coronary Surgery-An Important Tool in Graft Verification

    Directory of Open Access Journals (Sweden)

    Emir Mujanović

    2007-08-01

    Full Text Available The aim of this study was to analyze the Transit time flow measurement (TTFM experience in the first 1000 CABG operations. First 1000 patients had coronary artery bypass grafting (CABG performed in Cardiovascular Clinic, University Clinical Centre Tuzla, Bosnia and Herzegovina, between September, 1998 and September, 2003. CABG without use of cardio-pulmonary bypass (CPB-(OPCAB was used as the preferential surgical method both because this method is reported to have equal or better results than CABG with use of CPB (ONCAB, and because of the significant cost savings realized. TTFM was routinely used in all grafts as a quality assurance measure. Criteria for a poor functioning graft were: low mean flow (MF, pul-satility index (PI above 5 and a poor diastolic flow pattern. When no reversible cause of poor TTFM results were identified the graft was revised. A total of 1394 grafts in OPCAB group and 1478 in ONCAB group were performed. A total of 38 grafts (2,72% in 37 patients (7,07% were revised in OPCAB group, and 26 grafts (1,75% in 26 patients (5,45% in ONCAB group. 1 patient in OPCAB group needed 2 graft revisions. Graft revisions were more common in OPCAB, but with no significant difference (p=0,1035. The most frequently revised graft was LAD graft in both groups. Although the percentage of grafts revised are relatively low, it is still very important to record TTFM. More than 5% of patients in both groups needed graft revision. Although TTFM does not guarantee that grafts will stay open for a prolonged period of time we certainly believe that grafts that are occluded at the time of surgery will continue to stay occluded. TTFM is especially critical in OPCAB surgery where the technical challenge of grafting is higher then in ONCAB.