WorldWideScience

Sample records for bone subtraction cta

  1. Detection of intracranial aneurysms using three-dimensional multidetector-row CT angiography: Is bone subtraction necessary?

    International Nuclear Information System (INIS)

    Hwang, Seung Bae; Kwak, Hyo Sung; Han, Young Min; Chung, Gyung Ho

    2011-01-01

    Purpose: The aim of this study was to evaluate the usefulness of three-dimensional CT angiography (3D CTA) with bone subtraction in a comparison with 3D CTA without bone subtraction for the detection of intracranial aneurysms. Materials and methods: Among 337 consecutive patients who had intracranial aneurysms detected on 3D CTA, 170 patients who underwent digital subtraction angiography (DSA) were included in the study. CTA was performed with a 16-slice multidetector-row CT (MDCT) scanner. We created the 3D reconstruction images with and without bone subtraction by using the volume rendering technique. Three neuroradiologists in a blinded fashion interpreted both 3D CTA images with and without bone subtraction. The diagnostic accuracy of both techniques was evaluated using the alternative free-response receiver operating characteristic (ROC) analysis. The sensitivity and positive predictive value were also evaluated. Results: A total of 200 aneurysms (size: 2-23 mm) were detected in 170 patients. The area under the receiver operating characteristic curve (Az) for 3D CTA with bone subtraction (mean, Az = 0.933) was significantly higher than that for 3D CTA without bone subtraction (mean, Az = 0.879) for all observers (P < 0.05). The sensitivity of 3D CTA with bone subtraction for three observers was 90.0, 92.0 and 92.5%, respectively, while the sensitivity of 3D CTA without bone subtraction was 83.5, 83.5 and 87.5%, respectively. No significant difference in positive predictive value was observed between the two modalities. Conclusions: 3D CTA with bone subtraction showed significantly higher diagnostic accuracy for the detection of intracranial aneurysms as compared to 3D CTA without bone subtraction.

  2. Clinical evaluation of dual-energy bone removal in CT angiography of the head and neck: comparison with conventional bone-subtraction CT angiography

    International Nuclear Information System (INIS)

    Deng, K.; Liu, C.; Ma, R.; Sun, C.; Wang, X.-M.; Ma, Z.-T.; Sun, X.-L.

    2009-01-01

    Aim: To evaluate the bone-subtraction effect of dual-energy bone removal in computed tomography angiography (CTA) of the head and neck in comparison with conventional bone-subtraction CTA. Material and Methods: The study comprised 52 patients who were divided into two groups at random, and examined using dual-source CT for head and neck CTA. Dual-energy bone removal CTA and conventional bone-subtraction CTA were applied to each of the two groups, respectively. The bone subtraction was performed automatically in both methods. Vascular structures, as well as brain tissue remained visible. The subtracted images were further processed with maximum intensity projection (MIP) and volume-rendering technique (VRT) for image evaluation. Two experienced radiologists reviewed the resulting subtracted and non-subtracted volume data with respect to the delineation and detection of image quality and vascular pathology. Results: The means of the weighted CT dose index (CTDIvol) for bone-removal dual-energy CTA and conventional bone-subtraction CTA were 20.56 ± 0.01 mGy and 25.57 ± 0.56 mGy, respectively. There was a significant difference between them. The percentage of carotid and vertebral arteries and all other vessels that could be successfully assessed with these two methods were 87.8, 68, and 83%, and 93.5, 91.8, and 92.6%, respectively. There were no significant differences in the visualization of the carotid arteries; however, there were significant differences in the visualization of the vertebral arteries. Conclusion: Compared with conventional bone-subtraction CTA, dual-energy bone-removal CTA had a lower radiation dose. It eliminated most bones in the head and neck successfully; however, the bone subtraction effect around the vertebral artery was unsatisfactory. Dual-energy bone-removal CTA provides a new method for detecting vascular diseases in routine clinical work.

  3. Comparison of X-ray radiation exposure during digital subtraction angiography (DSA) and multislice CT angiography (CTA)

    International Nuclear Information System (INIS)

    Bai, Mei; Liu, Bin; Zheng, Junzheng

    2008-01-01

    Full text: Purpose: To compare radiation risk during digital subtraction angiography (DSA) and CT angiography (CTA). Materials and methods: Eighty patients randomly divided into two groups of 40 patients each, were evaluated for coronary atherosclerotic heart disease with 64-slice spiral CT angiography and DSA respectively. For CTA group we divided patients into two subgroups: regular mode and ECG modulation mode. Matix of thermoluminescent dosimeters (TLDs) were placed on patients' skin surface during each examination to access peak skin dose (PSD). A male ART phantom was equipped with TLDs in six different positions to assess achievable organ dose. Effective dose was calculated by commercially available computer programs. Results: For DSA, PSD was 64mGy. Phantom organ dose for lung, heart, stomach, liver, kidney and brain were 11.07mGy, 5.87mGy, 1.42mGy, 2.11mGy, 6.76mGy and 0.001mGy respectively, and effective dose was 4mSv. For regular mode CTA, PSD was 74.5mGy, and CTD vol was 37.9mGy. Phantom organ dose for lung, heart, stomach, liver, kidney and brain were 58mGy, 64.2mGy, 6.6mGy, 9.9mGy, 2.7mGy, 0.072mGy respectively, and effective dose was 16mSv. For ECG modulation mode, PSD was 50.9mGy, and CTD vol was 26.3mGy. Conclusion: According to measured PSD value, deterministic radiation risk for regular mode CTA was little higher than DSA. However for stochastic radiation risk which can be indicated by organ dose and effective dose, regular mode CTA was much higher than DSA. Comparing with regular mode, ECG modulation mode can effectively reduce both stochastic and deterministic radiation risk. (author)

  4. Clinical evaluation of bone-subtraction CT angiography (BSCTA) in head and neck imaging

    International Nuclear Information System (INIS)

    Lell, M.; Anders, K.; Bautz, W.; Klotz, E.; Ditt, H.; Tomandl, B.F.

    2006-01-01

    Fifty-one patients were examined with bone subtraction CT angiography (BSCTA). Data were acquired on 4-and 64-slice spiral CT systems. The post-processing method is based on fully automatic registration of non-enhanced and contrast-enhanced CT data and subsequent selective bone removal. Vascular structures and brain tissue are retained with the original CTA noise level. Image quality and delineation of the pathologic process were assessed and artifacts introduced by the bone removal process recorded. The bone subtraction algorithm worked successfully in all examinations. The processing time was 6 min on average. Image quality was rated excellent in 20 (39%), good in 26 (51%) and acceptable in 5 (10%) patients. Ophthalmic arteries were visible in 12 (24%) patients bilaterally, in 13 (25%) patients unilaterally and in 26 (51%) patients at least at the origin. BSCTA improved visualization of the infraclinoid ICA and the vertebral arteries. The depiction of stenosis of the extracranial ICA and supraclinoid aneurysms was not significantly improved. In patients with suspicion of sinus thrombosis, BSCTA and conventional CTA yielded similar results. To conclude, BSCTA improves the visualization of vessels with close contact to bone and can improve the diagnostic accuracy and therapy planning of infraclinoid aneurysms. (orig.)

  5. Four-dimensional CT angiography (4D-CTA) in the evaluation of juvenile nasopharyngeal angiofibromas: comparison with digital subtraction angiography (DSA) and surgical findings.

    Science.gov (United States)

    Xiao, Zebin; Zheng, Yingyan; Li, Jian; Chen, Dehua; Liu, Fang; Cao, Dairong

    2017-12-01

    To explore the value of four-dimensional CT angiography (4D-CTA) in the preoperative evaluation of juvenile nasopharyngeal angiofibromas (JNAs) using 320-row volume CT. 4D-CTA and DSA data of 18 patients with histopathologically proven JNAs were retrospectively reviewed. The location, extent, feeding vessels and stage of JNAs were assessed by two radiologists independently and blindly. The agreements between both reviewers and between 4D-CTA and surgical findings for assessing the above indicators were analysed, respectively. The radiation dose and the number of feeding arteries between 4D-CTA and digital subtraction angiography (DSA) were also compared. 4D-CTA showed high diagnostic consistency with surgical pathology for JNAs with consistent rates of 96.2 and 100% in both reviewers, respectively. The effective dose of 4D-CTA was significantly less than that of DSA (p 0.05). 4D-CTA can provide a reliable preoperative diagnosis and assessment of JNAs, which is useful for determining the surgical strategy and management of this condition.

  6. The Role of Bone Subtraction Computed Tomographic Angiography in Determining Intracranial Aneurysms in Non-Traumatic Subarachnoid Hemorrhage

    International Nuclear Information System (INIS)

    Kayhan, Aysegul; Koc, Osman; Keskin, Suat; Keskin, Fatih

    2014-01-01

    The presence of blood in the subarachnoid space is an acute pathology with a serious risk of death and complications. The most common etiology (approximately 80%) is intracranial aneurysm. The aim of this study was to assess the role of bone subtracted computed tomographic angiography (BSCTA), a novel and noninvasive method for determining and characterizing intracranial aneurysms. Sixty consecutive patients with clinically suspected non-traumatic subarachnoid hemorrhage (SAH) were considered to enter the study. The subtraction quality was inadequate in ten patients; thus, they were excluded, leaving 50 patients (84.4%) in the study. Bone subtracted and non-subtracted 3D images were obtained from the BSCTA raw data sets. All images obtained by digital subtraction angiography (DSA), BSCTA, and computed tomographic angiography (CTA) were evaluated for the presence or absence of an aneurysm and the location, minimal sac diameter, and neck size ratio of the aneurysm. DSA was considered as the gold standard during the evaluation of the data. Of the 50 patients who participated in this study, 11 had no aneurysms as determined by both CTA and DSA. Examination of the remaining 39 patients revealed the presence of 51 aneurysms. While 3D-CTA could not detect six aneurysms that were located in the base of the skull, 3D-BSCTA easily detected them. Moreover, five aneurysms were only partially detected by 3D-CTA. According to this data, the sensitivity of 3D-BSCTA and 3D-CTA was calculated as 98% and 86.3%, respectively; the specificity was calculated as 100% and 90.9%, respectively, per aneurysm; and the sensitivity of 100% for 3D-BSCTA and 98% for 3D-CTA was achieved by using combined images with multi-planar reconstruction (MPR) and maximum intensity projection (MIP). BSCTA detected and characterized the aneurysms as well as DSA, and BSCTA and DSA gave concordant results in detecting aneurysms. BSCTA is easily accessible, less time consuming, and most importantly, a non

  7. The Role of Bone Subtraction Computed Tomographic Angiography in Determining Intracranial Aneurysms in Non-Traumatic Subarachnoid Hemorrhage

    Science.gov (United States)

    Kayhan, Aysegul; Koc, Osman; Keskin, Suat; Keskin, Fatih

    2014-01-01

    Background: The presence of blood in the subarachnoid space is an acute pathology with a serious risk of death and complications. The most common etiology (approximately 80%) is intracranial aneurysm. Objectives: The aim of this study was to assess the role of bone subtracted computed tomographic angiography (BSCTA), a novel and noninvasive method for determining and characterizing intracranial aneurysms. Patients and Methods: Sixty consecutive patients with clinically suspected non-traumatic subarachnoid hemorrhage (SAH) were considered to enter the study. The subtraction quality was inadequate in ten patients; thus, they were excluded, leaving 50 patients (84.4%) in the study. Bone subtracted and non-subtracted 3D images were obtained from the BSCTA raw data sets. All images obtained by digital subtraction angiography (DSA), BSCTA, and computed tomographic angiography (CTA) were evaluated for the presence or absence of an aneurysm and the location, minimal sac diameter, and neck size ratio of the aneurysm. DSA was considered as the gold standard during the evaluation of the data. Results: Of the 50 patients who participated in this study, 11 had no aneurysms as determined by both CTA and DSA. Examination of the remaining 39 patients revealed the presence of 51 aneurysms. While 3D-CTA could not detect six aneurysms that were located in the base of the skull, 3D-BSCTA easily detected them. Moreover, five aneurysms were only partially detected by 3D-CTA. According to this data, the sensitivity of 3D-BSCTA and 3D-CTA was calculated as 98% and 86.3%, respectively; the specificity was calculated as 100% and 90.9%, respectively, per aneurysm; and the sensitivity of 100% for 3D-BSCTA and 98% for 3D-CTA was achieved by using combined images with multi-planar reconstruction (MPR) and maximum intensity projection (MIP). BSCTA detected and characterized the aneurysms as well as DSA, and BSCTA and DSA gave concordant results in detecting aneurysms. Conclusions: BSCTA is

  8. Bone marrow edema pattern identification in patients with lytic bone lesions using digital subtraction angiography-like bone subtraction on large-area detector computed tomography.

    Science.gov (United States)

    Gondim Teixeira, Pedro Augusto; Hossu, Gabriela; Lecocq, Sophie; Razeto, Marco; Louis, Matthias; Blum, Alain

    2014-03-01

    The objective of this study was to evaluate the performance of digital subtraction angiography (DSA)-like bone subtraction with 2 different registration methods for the identification of bone marrow edema pattern (BMEP) in patients with lytic bone lesions, using magnetic resonance imaging as the criterion standard. Fifty-five patients with a lytic bone lesion were included in this prospective study with approval from the ethics committee. All patients underwent magnetic resonance imaging and low-dose computed tomographic (CT) perfusion after signing an informed consent. Two CT volumes were used for bone subtraction, which was performed with 2 different algorithms (rigid and nonrigid). Enhancement at the nonlytic bone marrow was considered as a sign of BMEP. Two readers evaluated the images blindly. The presence of BMEP on bone-subtracted CT images was evaluated subjectively and quantitatively. Image quality was assessed. Magnetic resonance imaging was used as the criterion standard. Using a rigid registration method, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CT with DSA-like bone subtraction BMEP was 77%, 100%, 100%, 68%, and 85%, respectively. The interobserver agreement was good (κ, 0.782). Image quality was better using a nonrigid registration. With this algorithm, artifacts interfered with image interpretation in only 5% of cases. However, there was a noticeable drop in sensitivity and negative predictive value when a nonrigid algorithm was used: 56% and 52%, respectively. The interobserver agreement was average with a nonrigid subtraction algorithm. Computed tomography with DSA-like bone subtraction is sensitive and highly specific for the identification of BMEP associated with lytic bone lesions. Rigid registering should be preferred, but nonrigid algorithms can be used as a second option when artifacts interfere with image interpretation.

  9. Dual-energy CT head bone and hard plaque removal for quantification of calcified carotid stenosis: utility and comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Uotani, Kensuke; Watanabe, Yoshiyuki; Higashi, Masahiro; Nakazawa, Tetsuro; Kono, Atsushi K.; Hori, Yoshiro; Fukuda, Tetsuya; Kanzaki, Suzu; Yamada, Naoaki; Naito, Hiroaki; Itoh, Toshihide; Sugimura, Kazuro

    2009-01-01

    We evaluated quantification of calcified carotid stenosis by dual-energy (DE) CTA and dual-energy head bone and hard plaque removal (DE hard plaque removal) and compared the results to those of digital subtraction angiography (DSA). Eighteen vessels (13 patients) with densely calcified carotid stenosis were examined by dual-source CT in the dual-energy mode (tube voltages 140 kV and 80 kV). Head bone and hard plaques were removed from the dual-energy images by using commercial software. Carotid stenosis was quantified according to NASCET criteria on MIP images and DSA images at the same plane. Correlation between DE CTA and DSA was determined by cross tabulation. Accuracies for stenosis detection and grading were calculated. Stenosis could be evaluated in all vessels by DE CTA after applying DE hard plaque removal. In contrast, conventional CTA failed to show stenosis in 13 out of 18 vessels due to overlapping hard plaque. Good correlation between DE plaque removal images and DSA images was observed (r 2 =0.9504) for stenosis grading. Sensitivity and specificity to detect hemodynamically relevant (>70%) stenosis was 100% and 92%, respectively. Dual-energy head bone and hard plaque removal is a promising tool for the evaluation of densely calcified carotid stenosis. (orig.)

  10. Clinical utility of Gd-DTPA subtraction MR imaging for spinal bone metastasis

    International Nuclear Information System (INIS)

    Ando, Keiichi; Murakami, Masao; Kuroda, Yasumasa

    1993-01-01

    Based on reports that Gd-DTPA contributes to the detection of tumors, we used it in 31 cases (97 lesions) of spinal bone metastases. The result was that Gd-DTPA increased the intensity of tumors and the surrounding bone marrow to almost the same level in 53%. To show the metastases clearly, an existing subtraction command system was utilized. The technique included the pixel-by-pixel method, to obtain a Gd-DTPA T1-weighted image (T1WI) subtracted by the original T1WI. The detectability of the subtraction image was improved up to 96%, but was less than the original T1WI (99%). Because of the different imaging rationale between two methods, a means to assess the quality of diagnosis must be proposed. To check the normal background, the same kind of postprocessing was performed in 21 patients without malignancy. Gd-DTPA prefusion was highest in the paravertebral veins, moderate in muscles and epidural fat, and lowest in the spinal cord, intervertebral disk and bone cortex. Gd-DTPA enhanced subtraction MR imaging provides a new diagnostic tool to detect and to assess bone metastasis. (author)

  11. Bone images from dual-energy subtraction chest radiography in the detection of rib fractures.

    Science.gov (United States)

    Szucs-Farkas, Zsolt; Lautenschlager, Katrin; Flach, Patricia M; Ott, Daniel; Strautz, Tamara; Vock, Peter; Ruder, Thomas D

    2011-08-01

    To assess the sensitivity and image quality of chest radiography (CXR) with or without dual-energy subtracted (ES) bone images in the detection of rib fractures. In this retrospective study, 39 patients with 204 rib fractures and 24 subjects with no fractures were examined with a single exposure dual-energy subtraction digital radiography system. Three blinded readers first evaluated the non-subtracted posteroanterior and lateral chest radiographs alone, and 3 months later they evaluated the non-subtracted images together with the subtracted posteroanterior bone images. The locations of rib fractures were registered with confidence levels on a 3-grade scale. Image quality was rated on a 5-point scale. Marks by readers were compared with fracture localizations in CT as a standard of reference. The sensivity for fracture detection using both methods was very similar (34.3% with standard CXR and 33.5% with ES-CXR, p=0.92). At the patient level, both sensitivity (71.8%) and specificity (92.9%) with or without ES were identical. Diagnostic confidence was not significantly different (2.61 with CXR and 2.75 with ES-CXR, p=0.063). Image quality with ES was rated higher than that on standard CXR (4.08 vs. 3.74, prib fractures. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  12. Bone images from dual-energy subtraction chest radiography in the detection of rib fractures

    Energy Technology Data Exchange (ETDEWEB)

    Szucs-Farkas, Zsolt, E-mail: zsolt.szuecs@insel.ch [Department of Diagnostic, Interventional and Pediatric Radiology, University Hospital Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland); Lautenschlager, Katrin, E-mail: katrin@students.unibe.ch [Department of Diagnostic, Interventional and Pediatric Radiology, University Hospital Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland); Flach, Patricia M., E-mail: patricia.flach@irm.unibe.ch [Institute of Forensic Medicine, University of Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland); Ott, Daniel, E-mail: daniel.ott@insel.ch [Department of Diagnostic, Interventional and Pediatric Radiology, University Hospital Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland); Strautz, Tamara, E-mail: tamara.strautz@insel.ch [Department of Diagnostic, Interventional and Pediatric Radiology, University Hospital Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland); Vock, Peter, E-mail: peter.vock@insel.ch [Department of Diagnostic, Interventional and Pediatric Radiology, University Hospital Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland); Ruder, Thomas D., E-mail: thomas.ruder@irm.unibe.ch [Institute of Forensic Medicine, University of Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland)

    2011-08-15

    Objective: To assess the sensitivity and image quality of chest radiography (CXR) with or without dual-energy subtracted (ES) bone images in the detection of rib fractures. Materials and methods: In this retrospective study, 39 patients with 204 rib fractures and 24 subjects with no fractures were examined with a single exposure dual-energy subtraction digital radiography system. Three blinded readers first evaluated the non-subtracted posteroanterior and lateral chest radiographs alone, and 3 months later they evaluated the non-subtracted images together with the subtracted posteroanterior bone images. The locations of rib fractures were registered with confidence levels on a 3-grade scale. Image quality was rated on a 5-point scale. Marks by readers were compared with fracture localizations in CT as a standard of reference. Results: The sensivity for fracture detection using both methods was very similar (34.3% with standard CXR and 33.5% with ES-CXR, p = 0.92). At the patient level, both sensitivity (71.8%) and specificity (92.9%) with or without ES were identical. Diagnostic confidence was not significantly different (2.61 with CXR and 2.75 with ES-CXR, p = 0.063). Image quality with ES was rated higher than that on standard CXR (4.08 vs. 3.74, p < 0.001). Conclusions: Despite a better image quality, adding ES bone images to standard radiographs of the chest does not provide better sensitivity or improved diagnostic confidence in the detection of rib fractures.

  13. Three dimensional mapping of strontium in bone by dual energy K-edge subtraction imaging

    International Nuclear Information System (INIS)

    Cooper, D M L; Chapman, L D; Carter, Y; Zhouping, W; Wu, Y; Panahifar, A; Duke, M J M; Doschak, M; Britz, H M; Bewer, B

    2012-01-01

    The bones of many terrestrial vertebrates, including humans, are continually altered through an internal process of turnover known as remodeling. This process plays a central role in bone adaptation and disease. The uptake of fluorescent tetracyclines within bone mineral is widely exploited as a means of tracking new tissue formation. While investigation of bone microarchitecture has undergone a dimensional shift from 2D to 3D in recent years, we lack a 3D equivalent to fluorescent labeling. In the current study we demonstrate the ability of synchrotron radiation dual energy K-edge subtraction (KES) imaging to map the 3D distribution of elemental strontium within rat vertebral samples. This approach has great potential for ex vivo analysis of preclinical models and human tissue samples. KES also represents a powerful tool for investigating the pharmokinetics of strontium-based drugs recently approved in many countries around the globe for the treatment of osteoporosis. (paper)

  14. Quantitative analysis of alveolar bone change following implant placement using intraoral radiographic subtraction

    International Nuclear Information System (INIS)

    Kimura, Hiroyuki; Kanda, Shigenobu; Tanaka, Takemasa

    2002-01-01

    The purpose of this study was to develop a procedure for quantitative analysis using intraoral radiographs of alveolar bone after placement of dental implants and to consider the validity of the method. We evaluated the ten patients (2 males and 8 females, average age: 48.4 years-old), who were treated with dental implant operation in the site of mandibular molar region, since October of 1999 until September of 2000 in Kimura Dental Clinic (Kumamoto, Japan). We evaluated the intraoral radiographs taken pre- and post- operatively and at follow-up examination. To detect alveolar bone change on radiograph, we adopted the digital subtraction method. Although the radiographs were taken under an ordinary technique with cone indicator, we did not apply the standardized technique with fixing material customized for each patient. Therefore, we used geometric correction and density compensation before subtraction. We assessed the basic statistical values (mean, variance, kurtosis and skewness) of the region of interest (ROI) of the subtracted images. Also, we noted PPD (probing pocket depth) and BOP (bleeding on probing) at each site as indicators of clinical findings and all implanted sites were classified according to the PPD or BOP, i.e. PPD increased group ''PPD (+)'' and PPD stable group ''PPD (-)'', likewise BOP positive group ''BOP (+)'' and negative group ''BOP (-)''. We considered the statistical values of ROI in each group and compared these findings. Mean and variance values of PPD (+) were higher than those of PPD (-) and there was a significant difference in mean value (p=0.031). Similarly, mean and variance values of BOP (+) were statistically higher than those of BOP (-) (p=0.041 and p=0.0087, respectively). Concerning kurtosis and skewness, there was no difference between PPD (+) and PPD (-), or between BOP (+) and BOP (-). Using our method, the radiographs taken for follow-up examination could be assessed quantitatively. It is suggested that geometric

  15. Evaluation of the utility of temporal subtraction images in successive whole-body bone scans: a prospective clinical study

    International Nuclear Information System (INIS)

    Shiraishi, J.; Appelbaum, D.; Pu, Y.; Engelmann, R.; Li Qiang; Doi, K.

    2007-01-01

    We have begun a prospective clinical study for evaluating the clinical utility of temporal subtraction images in successive whole-body bone scans. The computerized temporal subtraction technique has been developed in order to highlight interval changes of abnormal lesions due to skeletal metastases, primary bone tumors, osteomyelitis, and fractures. In our initial preliminary results of the prospective study which was started on November 22, 2006 in our hospital, radiologists reported some interval changes which were not recognized in the initial standard readings, but were obvious when temporal subtraction images were viewed. The usefulness of the temporal subtraction images will be investigated in terms of its clinical utility by the prospective clinical study. (orig.)

  16. Spectral K-edge subtraction imaging of experimental non-radioactive barium uptake in bone.

    Science.gov (United States)

    Panahifar, Arash; Samadi, Nazanin; Swanston, Treena M; Chapman, L Dean; Cooper, David M L

    2016-12-01

    To evaluate the feasibility of using non-radioactive barium as a bone tracer for detection with synchrotron spectral K-edge subtraction (SKES) technique. Male rats of 1-month old (i.e., developing skeleton) and 8-month old (i.e., skeletally mature) were orally dosed with low dose of barium chloride (33mg/kg/day Ba 2+ ) for 4weeks. The fore and hind limbs were dissected for imaging in projection and computed tomography modes at 100μm and 52μm pixel sizes. The SKES method utilizes a single bent Laue monochromator to prepare a 550eV energy spectrum to encompass the K-edge of barium (37.441keV), for collecting both 'above' and 'below' the K-edge data sets in a single scan. The SKES has a very good focal size, thus limits the 'crossover' and motion artifacts. In juvenile rats, barium was mostly incorporated in the areas of high bone turnover such as at the growth plate and the trabecular surfaces, but also in the cortical bone as the animals were growing at the time of tracer administration. However, the adults incorporated approximately half the concentration and mainly in the areas where bone remodeling was predominant and occasionally in the periosteal and endosteal layers of the diaphyseal cortical bone. The presented methodology is simple to implement and provides both structural and functional information, after labeling with barium, on bone micro-architecture and thus has great potential for in vivo imaging of pre-clinical animal models of musculoskeletal diseases to better understand their mechanisms and to evaluate the efficacy of pharmaceuticals. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  17. [Quantitative image of bone mineral content--dual energy subtraction in a single exposure].

    Science.gov (United States)

    Katoh, T

    1990-09-25

    A dual energy subtraction system was constructed on an experimental basis for the quantitative image of bone mineral content. The system consists of a radiography system and an image processor. Two radiograms were taken with dual x-ray energy in a single exposure using an x-ray beam dichromized by a tin filter. In this system, a film cassette was used where a low speed film-screen system, a copper filter and a high speed film-screen system were layered on top of each other. The images were read by a microdensitometer and processed by a personal computer. The image processing included the corrections of the film characteristics and heterogeneity in the x-ray field, and the dual energy subtraction in which the effect of the high energy component of the dichromized beam on the tube side image was corrected. In order to determine the accuracy of the system, experiments using wedge phantoms made of mixtures of epoxy resin and bone mineral-equivalent materials in various fractions were performed for various tube potentials and film processing conditions. The results indicated that the relative precision of the system was within +/- 4% and that the propagation of the film noise was within +/- 11 mg/cm2 for the 0.2 mm pixels. The results also indicated that the system response was independent of the tube potential and the film processing condition. The bone mineral weight in each phalanx of the freshly dissected hand of a rhesus monkey was measured by this system and compared with the ash weight. The results showed an error of +/- 10%, slightly larger than that of phantom experiments, which is probably due to the effect of fat and the variation of focus-object distance. The air kerma in free air at the object was approximately 0.5 mGy for one exposure. The results indicate that this system is applicable to clinical use and provides useful information for evaluating a time-course of localized bone disease.

  18. Identification of genes differentially regulated in rat alveolar bone wound healing by subtractive hybridization.

    Science.gov (United States)

    Ohira, T; Myokai, F; Shiomi, N; Yamashiro, K; Yamamoto, T; Murayama, Y; Arai, H; Nishimura, F; Takashiba, S

    2004-07-01

    Periodontal healing requires the participation of regulatory molecules, cells, and scaffold or matrix. Here, we hypothesized that a certain set of genes is expressed in alveolar bone wound healing. Reciprocal subtraction gave 400 clones from the injured alveolar bone of Wistar rats. Identification of 34 genes and analysis of their expression in injured tissue revealed several clusters of unique gene regulation patterns, including the up-regulation at 1 wk of cytochrome c oxidase regulating electron transfer and energy metabolism, presumably occurring at the site of inflammation; up-regulation at 2.5 wks of pro-alpha-2 type I collagen involving the formation of a connective tissue structure; and up-regulation at 1 and 2 wks and down-regulation at 2.5 and 4 wks of ubiquitin carboxyl-terminal hydrolase l3 involving cell cycle, DNA repair, and stress response. The differential expression of genes may be associated with the processes of inflammation, wound contraction, and formation of a connective tissue structure.

  19. Digital subtraction radiography evaluation of the bone repair process of chronic apical periodontitis after root canal treatment.

    Science.gov (United States)

    Benfica e Silva, J; Leles, C R; Alencar, A H G; Nunes, C A B C M; Mendonça, E F

    2010-08-01

    To monitor radiographically the progress of bone repair within chronic periapical lesions after root canal treatment using digital subtraction radiography (DSR). Twelve patients with 17 single-rooted teeth with chronic apical periodontitis associated with an infected necrotic pulp were selected for root canal treatment. Periapical radiographs were taken before treatment (baseline) and immediately post-treatment, 45, 90, 135 and 180 days after treatment. The radiographic protocol included the use of individualized film holders with silicone bite blocks. The six radiographic images were digitized and submitted to digital subtraction using DSR software, resulting in five subtracted images (SI). Quantitative analysis of these SI was performed using Image Tool software to assess pixel value changes, considering a step-wedge as the gold standard and a cut-off value of 128 pixels. The aim was to identify any increase or decrease in mineral density in the region of the periapical lesion. A minor decrease in mineral density at the canal filling session and a significant progressive mineral gain in the following evaluations (P < 0.001) occurred. Pairwise comparison of pixel grey values revealed that only the 180-day follow-up differed significantly from the previous SI. Digital subtraction radiography is a useful method for evaluating the progress of bone repair after root canal treatment. Noticeable mineral gain was observed approximately 90 days after root canal filling and definite bone repair after 180 days.

  20. A digital subtraction radiography based tool for periodontal bone resorption analysis

    Energy Technology Data Exchange (ETDEWEB)

    Schiabel, Homero; Rodrigues, Eveline B., E-mail: homero@sc.usp.br [University of Sao Paulo (EESC/USP), Sao Carlos, SP (Brazil). Dept. of Electrical Engineering; Rubira-Bullen, Izabel R.F. [University of Sao Paulo (USP), Bauru, SP (Brazil). Bauru Dentistry School

    2011-07-01

    The aim of this paper was to describe an aided diagnosis scheme for periodontal bone resorption so that the dentist can make an early diagnosis of the periodontal disease and establish the best treatment plan to increase the success of healing. Three ways of displaying the results are provided: qualitative, simple quantitative and colored-percentage quantitative views. A total of 72 pairs of in vitro radiographic images were used. The main procedure registers the images perspective projection aimed to align them in rotation and translation, and is followed by the application of a contrast correction technique. The results from the subtraction were evaluated firstly by the comparison between the actual and the digital sizes corresponding to the holes made by drills in phantoms. The mean error was 4.2%. The method was also applied to actual tooth radiographic images and could detect clearly the effect of treatment of periodontal diseases. It is dependent on the reproducibility of the process of radiographs acquisition and digitization, but the calculated mean error allows to conclude its better efficacy compared to usual procedures in this field. (author)

  1. A digital subtraction radiography based tool for periodontal bone resorption analysis

    International Nuclear Information System (INIS)

    Schiabel, Homero; Rodrigues, Eveline B.; Rubira-Bullen, Izabel R.F.

    2011-01-01

    The aim of this paper was to describe an aided diagnosis scheme for periodontal bone resorption so that the dentist can make an early diagnosis of the periodontal disease and establish the best treatment plan to increase the success of healing. Three ways of displaying the results are provided: qualitative, simple quantitative and colored-percentage quantitative views. A total of 72 pairs of in vitro radiographic images were used. The main procedure registers the images perspective projection aimed to align them in rotation and translation, and is followed by the application of a contrast correction technique. The results from the subtraction were evaluated firstly by the comparison between the actual and the digital sizes corresponding to the holes made by drills in phantoms. The mean error was 4.2%. The method was also applied to actual tooth radiographic images and could detect clearly the effect of treatment of periodontal diseases. It is dependent on the reproducibility of the process of radiographs acquisition and digitization, but the calculated mean error allows to conclude its better efficacy compared to usual procedures in this field. (author)

  2. Construction and identification of subtracted cDNA library in bone marrow cells of radon-exposed mice

    International Nuclear Information System (INIS)

    Li Jianxiang; Nie Jihua; Tong Jian; Fu Chunling; Zhou Jianwei

    2008-01-01

    Objective: To construct and identify subtracted cDNA library in bone marrow cells of mice exposed to radon inhalation. Methods: Adult male BALB/c mice, weighing 18-22 g, were placed in a multi- functional radon chamber. One group of mice was exposed to radon up to the accumulative dose of 105 work level month (WLM). The control group of mice was housed in a room with an accumulative dose of 1 WLM. To construct a subtracted cDNA library enriched with differentially expressed genes, the SMART technique and the suppression subtractive hybridization were performed. The obtained forward and reverse cDNA fragments were directly inserted into pMD18-T vector and transformed into E. coli JM109. The inserting cDNA fragments were screened by the blue-and-white blot screening and nested PCR of bacterium liquid. Results: The 244 of 285 white bacteria clones obtained randomly were positive clones contained 100-1100 bp inserted cDNA fragments. Conclusions: The forward and reverse subtracted cDNA library in bone marrow cells of mice exposed to radon inhalation is successfully constructed. (authors)

  3. Femoral head vascularisation in Legg-Calve-Perthes disease: comparison of dynamic gadolinium-enhanced subtraction MRI with bone scintigraphy

    International Nuclear Information System (INIS)

    Lamer, Sylvie; Dorgeret, Sophie; Brillet, Pierre-Yves; Hassan, Max; Sebag, Guy H.; Khairouni, Abdeslam; Mazda, Keyvan; Bacheville, Eric; Pennecot, Georges F.; Bloch, Juliette

    2002-01-01

    Heading AbstractBackground. It has been reported that MRI using a dynamic gadolinium-enhanced subtraction technique can allow the early identification of ischaemia and the pattern of revascularisation in Legg-Calve-Perthes (LCP) disease with increased spatial and contrast resolution. Therefore, dynamic gadolinium-enhanced subtraction (DGS) MRI may be a possible non-ionising substitute for bone scintigraphy.Objective. The purpose of this prospective study was to compare DGS MRI and bone scintigraphy in the assessment of femoral head perfusion in LCP disease.Materials and methods. Twenty-six DGS MR images and bone scintigraphies of 25 hips in 23 children were obtained at different stages of LCP disease; three stage I, 12 stage II, six stage III and five stage IV (Waldenstroem classification). The extent of necrosis, epiphyseal revascularisation pathways (lateral pillar, medial pillar, and/or transphyseal perfusion) and metaphyseal changes were analysed.Results. Total agreement between both techniques was noted in the depiction of epiphyseal necrosis (kappa=1), and metaphyseal abnormalities (kappa=0.9). DGS MRI demonstrated better revascularisation in the lateral (kappa=0.62) and medial pillars (kappa=0.52). The presence of basal transphyseal reperfusion was more conspicuous with MRI.Conclusions. DGS MRI allows early detection of epiphyseal ischaemia and accurate analysis of the different revascularisation patterns. These changes are directly related to the prognosis of LCP disease and can aid therapeutic decision making. (orig.)

  4. Improved MDCT monitoring of pelvic myeloma bone disease through the use of a novel longitudinal bone subtraction post-processing algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Horger, Marius; Thaiss, Wolfgang M.; Nikolaou, Konstantin; Kloth, Christopher [Eberhard-Karls-University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Ditt, Hendrik [Sector Imaging and Interventional Radiology, Siemens AG Healthcare, Forchheim (Germany); Weisel, Katja [Eberhard-Karls-University Tuebingen, Department of Internal Medicine II, Tuebingen (Germany); Fritz, Jan [Johns Hopkins University School of Medcine, Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Liao, Shu [Siemens Medical Solutions, Malvern, PA (United States)

    2017-07-15

    To evaluate the diagnostic performance of a novel CT post-processing software that generates subtraction maps of baseline and follow-up CT examinations in the course of myeloma bone lesions. This study included 61 consecutive myeloma patients who underwent repeated whole-body reduced-dose MDCT at our institution between November 2013 and June 2015. CT subtraction maps classified a progressive disease (PD) vs. stable disease (SD)/remission. Bone subtraction maps (BSMs) only and in combination with 1-mm (BSM+) source images were compared with 5-mm axial/MPR scans. Haematological response categories at follow-up were: complete remission (n = 9), very good partial remission (n = 2), partial remission (n = 17) and SDh (n = 19) vs. PDh (n = 14). Five-millimetre CT scan yielded PD (n = 14) and SD/remission (n = 47) whereas bone subtraction + 1-mm axial scans (BSM+) reading resulted in PD (n = 18) and SD/remission (n = 43). Sensitivity/ specificity/accuracy for 5-mm/1-mm/BSM(alone)/BSM + in ''lesion-by-lesion'' reading was 89.4 %/98.9 %/98.3 %/ 99.5 %; 69.1 %/96.9 %/72 %/92.1 % and 83.8 %/98.4 %/92.1 %/98.3 %, respectively. The use of BSM+ resulted in a change of response classification in 9.8 % patients (n = 6) from SD to PD. BSM reading is more accurate for monitoring myeloma compared to axial scans whereas BSM+ yields similar results with 1-mm reading (gold standard) but by significantly reduced reading time. (orig.)

  5. Improved MDCT monitoring of pelvic myeloma bone disease through the use of a novel longitudinal bone subtraction post-processing algorithm

    International Nuclear Information System (INIS)

    Horger, Marius; Thaiss, Wolfgang M.; Nikolaou, Konstantin; Kloth, Christopher; Ditt, Hendrik; Weisel, Katja; Fritz, Jan; Liao, Shu

    2017-01-01

    To evaluate the diagnostic performance of a novel CT post-processing software that generates subtraction maps of baseline and follow-up CT examinations in the course of myeloma bone lesions. This study included 61 consecutive myeloma patients who underwent repeated whole-body reduced-dose MDCT at our institution between November 2013 and June 2015. CT subtraction maps classified a progressive disease (PD) vs. stable disease (SD)/remission. Bone subtraction maps (BSMs) only and in combination with 1-mm (BSM+) source images were compared with 5-mm axial/MPR scans. Haematological response categories at follow-up were: complete remission (n = 9), very good partial remission (n = 2), partial remission (n = 17) and SDh (n = 19) vs. PDh (n = 14). Five-millimetre CT scan yielded PD (n = 14) and SD/remission (n = 47) whereas bone subtraction + 1-mm axial scans (BSM+) reading resulted in PD (n = 18) and SD/remission (n = 43). Sensitivity/ specificity/accuracy for 5-mm/1-mm/BSM(alone)/BSM + in ''lesion-by-lesion'' reading was 89.4 %/98.9 %/98.3 %/ 99.5 %; 69.1 %/96.9 %/72 %/92.1 % and 83.8 %/98.4 %/92.1 %/98.3 %, respectively. The use of BSM+ resulted in a change of response classification in 9.8 % patients (n = 6) from SD to PD. BSM reading is more accurate for monitoring myeloma compared to axial scans whereas BSM+ yields similar results with 1-mm reading (gold standard) but by significantly reduced reading time. (orig.)

  6. Influence of homeopathic treatment with comfrey on bone density around titanium implants: a digital subtraction radiography study in rats.

    Science.gov (United States)

    Sakakura, Celso Eduardo; Neto, Rubens Spin; Bellucci, Marina; Wenzel, Ann; Scaf, Gulnara; Marcantonio, Elcio

    2008-06-01

    The objective of this study was to evaluate the influence of homeopathic treatment with comfrey (Shymphytum officinalis 6CH) on radiographic bone density and area around titanium implants. Forty-eight rats were divided into two groups of 24 animals each: a control group (C) and a test group (SO). Each animal received one titanium micro-implant placed in the tibia. The animals in Group SO were subjected to 10 drops of comfrey 6CH per day mixed into their drinking water until the day of sacrifice. Eight animals of each group were sacrificed at 7, 14 and 28 days post-surgery, respectively. Standardized digital radiographs were obtained on the day of implant installation (baseline images) and on the day of sacrifice (final images). Digital subtraction of the two corresponding images was performed to evaluate changes in bone density and the area related to change around the implant between baseline and final images. Subtraction images demonstrated that a significant difference existed in mean shade of gray at 14 days post-surgery between Group SO (mean 175.3+/-14.4) and Group C (mean 146.2+/-5.2). Regarding the area in pixels corresponding to the bone gain in Group SO, the differences observed between the sacrifice periods and groups were only significant at 7 days sacrifice between Group SO (mean 171.2+/-21.9) and Group C (mean 64.5+/-60.4). Within the limits of this study, comfrey administration promotes an increase in radiographic bone density around titanium implants in the initial period of bone healing.

  7. Dose related, comparative evaluation of a novel bone-subtraction algorithm in 64-row cervico-cranial CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Siebert, E.; Bohner, G. [Department of Neuroradiology, Charite Universitary Medicine Berlin (Germany); Dewey, M.; Bauknecht, C. [Department of Radiology, Charite Universitary Medicine Berlin (Germany); Klingebiel, R. [Department of Neuroradiology, Charite Universitary Medicine Berlin (Germany)], E-mail: randolf.klingebiel@charite.de

    2010-01-15

    Purpose: Comparative evaluation of a low-dose scan protocol for a novel bone-subtraction (BS) algorithm, applicable to 64-row cervico-cranial (cc) CT angiography (MSCTA). Methods and patients: BS algorithm assessment was performed in cadaveric phantom studies by stepwise variation of tube current and head malrotation using a 64-row CT scanner. In order to define minimum dose requirements and the rotation correction capacity, a low dose BS MSCTA protocol was defined and evaluated in 12 patients in comparison to a common manual bone removal algorithm. Standard MIPs of both modalities were evaluated in a blinded manner by two neuroradiologists for image quality composed, of vessel contour sharpness and bony vessel superposition, by using a five-point score each. Effective Dose (E) and data post-processing times were defined. Results: In experimental studies prescan tube current could be cut down to one-sixth of post-contrast scan doses without compromise of bone-subtraction whereas incomplete subtraction appeared from four degrees head malrotation on. Prescan E amounted to additional 1.1 mSv (+25%) in clinical studies. BS MSCTA performed significantly superior in terms of bony superposition for vascular segments C3-C7 (p < 0.001), V1-V2, V3-V4 (p < 0.05, p < 0.001 respectively) and the ophthalmic artery (p < 0.05), whereas vessel contour sharpness in BS MSCTA only proved superior for arterial segments V3-V4 (p < 0.001) and C3-C7 (p < 0.001). MBR MSCTA received higher ratings in vessel contour sharpness for C1-C2 (p < 0.001), callosomarginal artery (p < 0.001), M1, M2, M3 (p < 0.001 each) and the basilar artery (p < 0.001). Reconstruction times amounted to an average of 1.5 (BS MSCTA) and 3 min (MBR MSCTA) respectively. Conclusion: The novel BS algorithm provides superior skull base artery visualisation as compared to common manual bone removal algorithms, increasing the Effective Dose by one-fourth. Yet, inferior vessel contour sharpness was noted intracranially, thus

  8. Dose related, comparative evaluation of a novel bone-subtraction algorithm in 64-row cervico-cranial CT angiography

    International Nuclear Information System (INIS)

    Siebert, E.; Bohner, G.; Dewey, M.; Bauknecht, C.; Klingebiel, R.

    2010-01-01

    Purpose: Comparative evaluation of a low-dose scan protocol for a novel bone-subtraction (BS) algorithm, applicable to 64-row cervico-cranial (cc) CT angiography (MSCTA). Methods and patients: BS algorithm assessment was performed in cadaveric phantom studies by stepwise variation of tube current and head malrotation using a 64-row CT scanner. In order to define minimum dose requirements and the rotation correction capacity, a low dose BS MSCTA protocol was defined and evaluated in 12 patients in comparison to a common manual bone removal algorithm. Standard MIPs of both modalities were evaluated in a blinded manner by two neuroradiologists for image quality composed, of vessel contour sharpness and bony vessel superposition, by using a five-point score each. Effective Dose (E) and data post-processing times were defined. Results: In experimental studies prescan tube current could be cut down to one-sixth of post-contrast scan doses without compromise of bone-subtraction whereas incomplete subtraction appeared from four degrees head malrotation on. Prescan E amounted to additional 1.1 mSv (+25%) in clinical studies. BS MSCTA performed significantly superior in terms of bony superposition for vascular segments C3-C7 (p < 0.001), V1-V2, V3-V4 (p < 0.05, p < 0.001 respectively) and the ophthalmic artery (p < 0.05), whereas vessel contour sharpness in BS MSCTA only proved superior for arterial segments V3-V4 (p < 0.001) and C3-C7 (p < 0.001). MBR MSCTA received higher ratings in vessel contour sharpness for C1-C2 (p < 0.001), callosomarginal artery (p < 0.001), M1, M2, M3 (p < 0.001 each) and the basilar artery (p < 0.001). Reconstruction times amounted to an average of 1.5 (BS MSCTA) and 3 min (MBR MSCTA) respectively. Conclusion: The novel BS algorithm provides superior skull base artery visualisation as compared to common manual bone removal algorithms, increasing the Effective Dose by one-fourth. Yet, inferior vessel contour sharpness was noted intracranially, thus

  9. Small lung cancers: improved detection by use of bone suppression imaging--comparison with dual-energy subtraction chest radiography.

    Science.gov (United States)

    Li, Feng; Engelmann, Roger; Pesce, Lorenzo L; Doi, Kunio; Metz, Charles E; Macmahon, Heber

    2011-12-01

    To determine whether use of bone suppression (BS) imaging, used together with a standard radiograph, could improve radiologists' performance for detection of small lung cancers compared with use of standard chest radiographs alone and whether BS imaging would provide accuracy equivalent to that of dual-energy subtraction (DES) radiography. Institutional review board approval was obtained. The requirement for informed consent was waived. The study was HIPAA compliant. Standard and DES chest radiographs of 50 patients with 55 confirmed primary nodular cancers (mean diameter, 20 mm) as well as 30 patients without cancers were included in the observer study. A new BS imaging processing system that can suppress the conspicuity of bones was applied to the standard radiographs to create corresponding BS images. Ten observers, including six experienced radiologists and four radiology residents, indicated their confidence levels regarding the presence or absence of a lung cancer for each lung, first by using a standard image, then a BS image, and finally DES soft-tissue and bone images. Receiver operating characteristic (ROC) analysis was used to evaluate observer performance. The average area under the ROC curve (AUC) for all observers was significantly improved from 0.807 to 0.867 with BS imaging and to 0.916 with DES (both P chest radiographs. Further improvements can be achieved by use of DES radiography but with the requirement for special equipment and a potential small increase in radiation dose. © RSNA, 2011.

  10. Dual energy CT of peripheral arteries: Effect of automatic bone and plaque removal on image quality and grading of stenoses

    International Nuclear Information System (INIS)

    Meyer, B.C.; Werncke, T.; Hopfenmueller, W.; Raatschen, H.J.; Wolf, K.-J.; Albrecht, T.

    2008-01-01

    Purpose: To evaluate the effect of automatic bone and plaque removal on image quality and grading of steno-occlusive lesions in patients undergoing dual energy CT angiography (CTA) of lower extremity. Materials and methods: Dual energy (DE) runoff CTA was performed in 50 patients using the following parameters: collimation 2 x 32 x 0.6; tube potentials, 80 kV and 140 kV; reconstructed slice thickness 1 mm. 100 mL iomeprol 400 and 50 mL saline were injected at 4 mL/s. Separate datasets were calculated for each of the two tubes and used to generate automatically bone-subtracted images (ABS) as well as bone and plaque subtracted images (ABPS). Residual bone in the ABS dataset was removed manually (=ABS-B dataset). In addition, a weighted average dataset from both dual energy acquisitions resembling a routine 120 kV CT acquisition was used for standard manual bone subtraction (MBS). Operator time for bone removal was measured. Effectiveness of bone subtraction and presence of vessel erosions was assessed by two readers in consensus. Stenosis grading in plaque subtracted and unsubtracted images was assessed and correlated. Results: Residual bone fragments (ribs: 46%, patella: 25%, spine: 4%, pelvis: 2%, tibia 2% of patients) were only observed with ABS. The time needed to manually remove these residual bones was 2.1 ± 1.1 min and was significantly lower than the duration of manual bone removal (6.8 ± 2.0 min, p < 0.0001, paired t-test). A total of 1159 arteries were analyzed. Compromising vessel erosions were observed less frequently in the ABS-B dataset (10.6%) than in the MBS dataset (15.2%, p < 0.001, wilcoxon's signed rank test). A total of 817 steno-occlusive lesions were assessed. While the agreement of grading of steno-occlusive lesions was good at the levels of the aorta and the pelvic arteries (κ = 0.70 in both, Cohen's kappa statistics), it was moderate at the level of the thigh arteries (κ = 0.57) and poor at the level of the calf (κ = 0.16). Conclusion

  11. A quantitative study of bone repair after endodontic therapy on digital subtraction radiography

    International Nuclear Information System (INIS)

    Kim, Jae Duk

    1997-01-01

    This study was performed to prepare the quantitative method of judging the sensitive prognosis of chronic apical periodontitis as early as possible. The subjects were 25 cases with periapical radiolucencies of which were treated with endodontic treatment. Serial radiographs were taken by standardized method longitudinally. The density slice function of digital radiographic system were employed for quantitative and longitudinal assessment of the radiolucent area and the condensing osteitis simultaneously. Obtained results were as follows: 1. The amount of bone repair after endodontic treatment could be detected quantitatively by the density slice function of digital radiographic system. 2. Within the 6-week period after root canal filling, the prognosis could be evaluated by assessment both radiolucent area and condensing osteitis on digital radiographic system. 3. The pattern of bone repair showed peripheral type in most cases from the 6th week after root canal filling. 4. In longitudinal change, bone repair showed two patterns; the succeeding reduction of radiolucent area showing the increase of condensing osteitis in size till 6th week and following by static state or reduction tendency and the reduction following the initial increase of both areas. 5. Cases with pulpitis by trauma showed initial increase of condensing osteitis at 2nd week, marked reduction of radiolucent area and condensing osteitis at 6th week, and approximately normal bone state at 8th week after root canal filling.

  12. A quantitative study of bone repair after endodontic therapy on digital subtraction radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Duk [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Chosun University, Kwangju (Korea, Republic of)

    1997-08-15

    This study was performed to prepare the quantitative method of judging the sensitive prognosis of chronic apical periodontitis as early as possible. The subjects were 25 cases with periapical radiolucencies of which were treated with endodontic treatment. Serial radiographs were taken by standardized method longitudinally. The density slice function of digital radiographic system were employed for quantitative and longitudinal assessment of the radiolucent area and the condensing osteitis simultaneously. Obtained results were as follows: 1. The amount of bone repair after endodontic treatment could be detected quantitatively by the density slice function of digital radiographic system. 2. Within the 6-week period after root canal filling, the prognosis could be evaluated by assessment both radiolucent area and condensing osteitis on digital radiographic system. 3. The pattern of bone repair showed peripheral type in most cases from the 6th week after root canal filling. 4. In longitudinal change, bone repair showed two patterns; the succeeding reduction of radiolucent area showing the increase of condensing osteitis in size till 6th week and following by static state or reduction tendency and the reduction following the initial increase of both areas. 5. Cases with pulpitis by trauma showed initial increase of condensing osteitis at 2nd week, marked reduction of radiolucent area and condensing osteitis at 6th week, and approximately normal bone state at 8th week after root canal filling.

  13. ITER CTA newsletter. No. 4

    International Nuclear Information System (INIS)

    2001-12-01

    This ITER CTA Newsletter contains information about the organization of the ITER Co-ordinated Technical Activities (CTA) International Team as the follow-up of the ITER CTA project board meeting in Toronto on 7 November 2001. It also includes a summary on the start of the international tokamak physics activity by Dr. D. Campbell, Chair of the ITPA Co-ordinating Committee

  14. Subtractive Leadership

    Science.gov (United States)

    Larwin, K. H.; Thomas, Eugene M.; Larwin, David A.

    2015-01-01

    This paper introduces a new term and concept to the leadership discourse: Subtractive Leadership. As an extension of the distributive leadership model, the notion of subtractive leadership refers to a leadership style that detracts from organizational culture and productivity. Subtractive leadership fails to embrace and balance the characteristics…

  15. ITER CTA newsletter. No. 9

    International Nuclear Information System (INIS)

    2002-06-01

    This ITER CTA newsletter contains information about the Fourth Negotiations Meeting on the Joint Implementation of ITER held in Cadarache, France on 4-6 June 2002 and about the meeting of the ITER CTA Project Board which took place on the occasion of the N4 Meeting at Cadarache on 3-4 June 2002

  16. ITER CTA newsletter. No. 1

    International Nuclear Information System (INIS)

    2001-01-01

    This ITER CTA newsletter comprises reports on ITER co-ordinated technical activities, information about the Meeting of the ITER CTA project board which took place in Vienna on 16 July 2001, and the Meeting of the expert group on MHD, disruptions and plasma control which was held on 25-26 June 2001 in Funchal, Madeira

  17. ITER CTA newsletter. No. 7

    International Nuclear Information System (INIS)

    2002-04-01

    This issue of ITER CTA newsletter contains information about the meeting of the ITER CTA project board, which took place in Moscow, Russian Federation on 22 April 2002 on the occasion of the Third Negotiators Meeting (N3), and about the meeting 'EU divertor celebration day' organized on 16 January 2002 at Plansee AG, Reutte, Austria

  18. ITER CTA newsletter. No. 3

    International Nuclear Information System (INIS)

    2001-11-01

    This ITER CTA newsletter comprises reports of Dr. P. Barnard, Iter Canada Chairman and CEO, about the progress of the first formal ITER negotiations and about the demonstration of details of Canada's bid on ITER workshops, and Dr. V. Vlasenkov, Project Board Secretary, about the meeting of the ITER CTA project board

  19. Dual-energy CTA in patients with symptomatic peripheral arterial occlusive disease. Study of diagnostic accuracy and impeding factors

    Energy Technology Data Exchange (ETDEWEB)

    Klink, Thorsten [Wuerzburg Univ. (Germany). Inst. of Diagnostic and Interventional Radiology; Bern Univ. (Switzerland). Univ. Inst. of Diagnostic, Interventional, and Pediatric Radiology; Wilhelm, Theresa; Roth, Christine [Univ. Hospital Giessen and Marburg, Marburg (Germany). Dept. of Diagnostic and Interventional Radiology; Heverhagen, Johannes T. [Bern Univ. (Switzerland). Univ. Inst. of Diagnostic, Interventional, and Pediatric Radiology

    2017-05-15

    The purpose of this study was to assess the diagnostic performance of dual-energy CT angiography (DE-CTA) in patients with symptomatic peripheral artery occlusive disease (PAOD) and to identify factors that impede its diagnostic accuracy. Dual-source DE-CTA scans of the lower extremities of 94 patients were retrospectively compared to the diagnostic reference standard, digital subtraction angiography (DSA). Two independent observers assessed PAOD incidence, image quality, artifacts, and diagnostic accuracy of DE-CTA in 1014 arterial segments on axial, combined 80/140 kVp reconstructions and on 3 D maximum intensity projections (MIP) after automated bone and plaque removal. The impact of calcifications, image quality, and image artifacts on the diagnostic accuracy was evaluated using Fisher's exact test. Furthermore, interobserver agreement was analyzed. Two observers achieved sensitivities of 98.0% and 93.9%, respectively, and specificities of 75.0% and 66.7%, respectively, for detecting stenoses of >50% of the lower extremity arteries. Calcifications impeded specificity, e.g. from 81.2% to 46.2% for reader 1 (p<0.001). Specificity increased with higher image quality, e.g. from 70.0% to 76.4% for reader 1 (p<0.001). Artifacts decreased the specificity of reader 2 (p<0.001). The overall interobserver agreement ranged between moderate and substantial for stenosis detection and calcified plaques. Conclusion DE-CTA is accurate in the detection of arterial stenoses of >50% in symptomatic PAOD patients. Calcified atherosclerotic plaques, image quality, and artifacts may impede specificity.

  20. ITER CTA newsletter. No. 8

    International Nuclear Information System (INIS)

    2002-05-01

    This ITER CTA newsletter contains information about the Third Negotiations Meeting on the Joint Implementation of ITER held in Moscow on 23-24 April 2002 and about the visit of Canadian officials and members of the Canadian delegation to RF research center 'Kurchatov Institute'

  1. ITER CTA newsletter. No. 6

    International Nuclear Information System (INIS)

    2002-01-01

    This ITER CTA Newsletter issue comprises information about the following ITER Meetings: The second negotiation meeting on the joint implementation of ITER, held in Tokyo(Japan) on 22-23 January 2002, and an international ITER symposium on burning plasma science and technology, held the day later after the second negotiation meeting at the same place

  2. ITER CTA newsletter. No. 2

    International Nuclear Information System (INIS)

    2001-10-01

    This ITER CTA newsletter contains results of the ITER toroidal field model coil project presented by ITER EU Home Team (Garching) and an article in commemoration of the late Dr. Charles Maisonnier, one of the former leaders of ITER who made significant contributions to its development

  3. VLBI imaging of CTA 102

    International Nuclear Information System (INIS)

    Wehrle, A.E.; Cohen, M.

    1989-01-01

    The object CTA 102, a low-frequency variable quasar, was observed with a VLBI Global Array in 1987.5 and 1988.5 at 5.0 GHz. The structure is complex, with three compact components along a line at PA = 157 deg, and several extended, ill-defined components east of the southernmost compact component. The components have no detectable relative motions, with mu less than 0.5 mas/yr along the main axis. This contrasts with the observation reported by Baath (1987), who found mu = 0.65 + or - 0.15 mas/yr at 932 MHz, which is exceptionally high. The new upper limit allows CTA 102 to be in the normal range of superluminal sources. 11 refs

  4. Diagnosis of renal artery stenosis : spiral CTA vs. IA-DSA

    International Nuclear Information System (INIS)

    Kim, Tae Sung; Chung, Jin Wook; Park, Jae Hyung; Kim, Seung Hyup; Yeon, Kyung Mo; Han, Man Chung

    1996-01-01

    To evaluate the accuracy of spiral CT angiography(CTA) in the demonstration of accessory or multiple renal arteries and renal artery stenosis. We prospectively performed CTA in 50 patients (24 males and 26 females) between nine and 77 years old (mean 39.3) in whom renovascular hypertension was suspected (n=32), or who were potential renal donors (n=18). Within two days of CTA, intraarterial digital subtraction angiography(IA-DSA) was performed. Both spiral CTA and IA-DSA images were blindly compared by two radiologists with respect to the number of accessory renal arteries and the location and severity of renal artery stenosis. The severity of renal arterial stenosis was graded with a five-point scale (grades 0-4). CTA demonstrated 26 of total 27 accessory renal arteries (detection rate=96.5%). For the diagnosis of grade 2-4 stenosis (≥50% stenosis) (n=40 of a total of 127 renal arteries), the sensitivity, specificity, and accuracy of CTA were 90%, 96.5%, and 94.5%, respectively. For the detection of grade 3-4 stenoses (≥75% stenosis) (n=33), the sensitivity, specificity, and accuracy of CTA were 87.9%, 98.9%, and 96.1%, respectively. For the detection of grade 3-4 stenoses in the main renal artery (n=27), the sensitivity, specificity, and accuracy of CTA were 96.3%, 100%, and 99.0%, respectively. Spiral CTA is a reliable and accurate screening modality for the evaluation of renal artery in patients suspected to be suffering from renovascular hypertension, or who are potential renal donors

  5. ITER CTA newsletter. No. 10

    International Nuclear Information System (INIS)

    2002-07-01

    This ITER CTA newsletter issue comprises the ITER backgrounder, which was approved as an official document by the participants in the Negotiations on the ITER Implementation agreement at their fourth meeting, held in Cadarache from 4-6 June 2002, and information about two ITER meetings: one is the third meeting of the ITER parties' designated Safety Representatives, which took place in Cadarache, France from 6-7 June 2002, and the other is the second meeting of the International Tokamak Physics Activity (ITPA) topical group on diagnostics, which was held at General Atomics, San Diego, USA, from 4-8 March 2002

  6. Digital subtraction CT angiography for the detection of posterior inferior cerebellar artery aneurysms: comparison with digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Guo Zhong; Luo, Song; Zhou, Chang Sheng; Zhang, Long Jiang; Lu, Guang Ming [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China)

    2017-09-15

    To evaluate the diagnostic accuracy of digital subtraction CT angiography (DS-CTA) in detecting posterior inferior cerebellar artery (PICA) aneurysms with digital subtraction angiography (DSA) as reference standard. A total of 115 patients, including 56 patients diagnosed with PICA aneurysms by CTA or DSA and 59 non-PICA-aneurysm patients were included in this retrospective study. All patients underwent DS-CTA and DSA. The site of PICA aneurysms and the pattern of haemorrhage were analysed. Sensitivity and specificity of DS-CTA without and with combining haemorrhage pattern in diagnosing PICA aneurysms were evaluated on a per patient and per aneurysm basis with DSA. Of 115 patients, 56 patients (48.7%) had 61 PICA aneurysms (size range, 1.1-13.5 mm; mean size, 4.9 ± 2.8 mm) on DSA. The sensitivity and specificity in depicting PICA aneurysms were 89.3% and 96.6% on a per patient basis and 90.2% and 93.4% on a per aneurysm basis, while the corresponding values were 94.6% and 96.6% on a per patient basis and 95.1% and 93.4% on a per aneurysm basis when combining with haemorrhage site. DS-CTA has a high sensitivity and specificity in detecting PICA aneurysms compared with DSA. It may be helpful for clinical diagnosis of PICA aneurysms to combine with haemorrhage sites. (orig.)

  7. Cerebral bone subtraction CT angiography using 80 kVp and sinogram-affirmed iterative reconstruction: contrast medium and radiation dose reduction with improvement of image quality

    Energy Technology Data Exchange (ETDEWEB)

    Nagayama, Yasunori [Kumamoto City Hospital, Department of Radiology, Kumamoto (Japan); Kumamoto University, Department of Diagnostic Radiology, Chuo-ku, Kumamoto (Japan); Nakaura, Takeshi; Oda, Seitaro; Kidoh, Masafumi; Utsunomiya, Daisuke; Yamashita, Yasuyuki [Kumamoto University, Department of Diagnostic Radiology, Chuo-ku, Kumamoto (Japan); Tsuji, Akinori; Urata, Joji; Furusawa, Mitsuhiro; Yuki, Hideaki; Hirarta, Kenichiro [Kumamoto City Hospital, Department of Radiology, Kumamoto (Japan)

    2017-02-15

    The purpose of this study was to evaluate the feasibility of a contrast medium (CM), radiation dose reduction protocol for cerebral bone-subtraction CT angiography (BSCTA) using 80-kVp and sinogram-affirmed iterative reconstruction (SAFIRE). Seventy-five patients who had undergone BSCTA under the 120- (n = 37) or the 80-kVp protocol (n = 38) were included. CM was 370 mgI/kg for the 120-kVp and 296 mgI/kg for the 80-kVp protocol; the 120- and the 80-kVp images were reconstructed with filtered back-projection (FBP) and SAFIRE, respectively. We compared effective dose (ED), CT attenuation, image noise, and contrast-to-noise ratio (CNR) of two protocols. We also scored arterial contrast, sharpness, depiction of small arteries, visibility near skull base/clip, and overall image quality on a four-point scale. ED was 62% lower at 80- than 120-kVp (0.59 ± 0.06 vs 1.56 ± 0.13 mSv, p < 0.01). CT attenuation of the internal carotid artery (ICA) and middle cerebral artery (MCA) was significantly higher on 80- than 120-kVp (ICA: 557.4 ± 105.7 vs 370.0 ± 59.3 Hounsfield units (HU), p < 0.01; MCA: 551.9 ± 107.9 vs 364.6 ± 62.2 HU, p < 0.01). The CNR was also significantly higher on 80- than 120-kVp (ICA: 46.2 ± 10.2 vs 36.9 ± 7.6, p < 0.01; MCA: 45.7 ± 10.0 vs 35.7 ± 9.0, p < 0.01). Visibility near skull base and clip was not significantly different (p = 0.45). The other subjective scores were higher with the 80- than the 120-kVp protocol (p < 0.05). The 80-kVp acquisition with SAFIRE yields better image quality for BSCTA and substantial reduction in the radiation and CM dose compared to the 120-kVp with FBP protocol. (orig.)

  8. ITER CTA newsletter. No. 15, December 2002

    International Nuclear Information System (INIS)

    2003-03-01

    This ITER CTA newsletter issue contains brief information about several meetings related to ITER. One of them is the seventh ITER Negotiations Meetings that took place in Barcelona, Spain on 9-10 December 2002, another is the final ITER CTA Project Board Meeting, which took place in Barcelona, Spain on 8 December 2002 and the last one is the Third Meeting of the International Tokamak Physics Activity (ITPA) Topical Group on diagnostics held in Toki, Japan on 18-21 September 2002

  9. Demonstration of the dorsal pancreatic artery by CTA to facilitate superselective arterial infusion of stem cells into the pancreas

    International Nuclear Information System (INIS)

    Lin Yuning; Yang Xizhang; Chen Ziqian; Tan Jianming; Zhong Qun; Yang Li; Wu Zhixian

    2012-01-01

    Purpose: To investigate the diagnostic performance of 64-section CTA in the detection of dorsal pancreatic artery before interventional therapy for patients with diabetes. Materials and methods: The study was approved by the institutional ethics committee; written informed consent was obtained. Forty-two consecutive patients with diabetes received an experimental treatment of autologous bone marrow-derived stem cell transplantation by means of infusion into the dorsal pancreatic artery. All cases underwent abdominal CTA before angiography of pancreatic arteries in order to locate the origin and course of dorsal pancreatic artery. Angiography of coeliac artery, splenic artery, common hepatic artery and superior mesenteric artery were performed both in CTA and DSA. Superselective catheterization of dorsal pancreatic artery was carried out for the infusion of stem cell. Sensitivity, specificity and accuracy for the detection of dorsal pancreatic artery with CTA were calculated using DSA images as the reference standard. Results: Thirty-five and thirty-six dorsal pancreatic arteries were detected by CTA and DSA respectively. Dorsal pancreatic artery was not visualized in either CTA or DSA in 5 patients. The sensitivity, specificity and accuracy for CTA were 94.4%, 83.3% and 92.9%. Conclusion: 64-section CTA is accurate for the detection of dorsal pancreatic artery. It may be useful for the facilitation of superselective arterial infusion of stem cells to pancreas.

  10. Dual energy CTA of the supraaortic arteries: Technical improvements with a novel dual source CT system

    International Nuclear Information System (INIS)

    Lell, Michael M.; Hinkmann, Fabian; Nkenke, Emeka; Schmidt, Bernhard; Seidensticker, Peter; Kalender, Willi A.; Uder, Michael; Achenbach, Stephan

    2010-01-01

    Objectives: Computed tomography angiography (CTA) is a well-accepted imaging modality to evaluate the supraaortic vessels. Initial reports have suggested that dual energy CTA (DE-CTA) can enhance diagnosis by creating bone-free data sets, which can be visualized in 3D, but a number of limitations of this technique have also been addressed. We sought to describe the performance of DE-CTA of the supraaortic vessels with a novel dual source CT system with special emphasis on image quality and post-processing related artifacts. Materials and methods: Thirty-three patients underwent carotid CT angiography on a second generation dual source CT system. Simultaneous acquisitions of 100 and 140 kV data sets in arterial phase were performed. Two examiners evaluated overall bone suppression with a 3-point scale (1 = poor; 3 = excellent) and image quality regarding integrity of the vessel lumen of different vessel segments (n = 26) with a 5-point scale (1 = poor; 5 = excellent), CTA source data served as the reference. Results: Excellent bone suppression could be achieved in the head and neck. Only minor bone remnants occurred, mean score for bone removal was 2.9. Mean score for vessel integrity was 4.3. Eight hundred fifty-seven vessel segments could be evaluated. Six hundred thirty-five segments (74%) showed no lumen alteration, 65 segments (7.6%) lumen alterations 10% resulting in a total luminal reduction 50%, and 113 segments (13.2%) showed a gap in the vessel course (100% total lumen reduction). Artificial gaps of the vessel lumen occurred in 28 vessel segments due to artifacts caused by dental hardware and in all but one (65) ophthalmic arteries. Conclusions: Excellent bone suppression could be achieved, DE imaging with 100 and 140 kV lead to improved image quality and vessel integrity in the shoulder region than previously reported. The ophthalmic artery still cannot be adequately visualized.

  11. Computed tomography versus digital subtraction angiography for the diagnosis of obscure gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Wildgruber, Moritz, E-mail: moritzwildgruber@ukmuenster.de [Institut für Röntgendiagnostik, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany); Institut für klinische Radiologie, Universitätsklinikum Münster, D-48149 Münster (Germany); Wrede, Christian E. [Notfallzentrum, Helios Klinikum Berlin-Buch, D-13125 Berlin (Germany); Zorger, Niels [Institut für Radiologie, Neuroradiologie und Nuklearmedizin, Krankenhaus Barmherzige Brüder, D-93049 Regensburg (Germany); Müller-Wille, René; Hamer, Okka W. [Institut für Röntgendiagnostik, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany); Zeman, Florian [Zentrum für Klinische Studien, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany); Stroszczynski, Christian; Heiss, Peter [Institut für Röntgendiagnostik, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany)

    2017-03-15

    Purpose: The diagnostic yield of computed tomography angiography (CTA) compared to digital subtraction angiography (DSA) for major obscure gastrointestinal bleeding (OGIB) is not known. Aim of the study was to prospectively evaluate the diagnostic yield of CTA versus DSA for the diagnosis of major OGIB. Material and methods: The institutional review board approved the study and informed consent was obtained from each patient. Patients with major OGIB were prospectively enrolled to undergo both CTA and DSA. Two blinded radiologists each reviewed the CTA and DSA images retrospectively and independently. Contrast material extravasation into the gastrointestinal lumen was considered diagnostic for active bleeding. Primary end point of the study was the diagnostic yield, defined as the frequency a technique identified an active bleeding or a potential bleeding lesion. The diagnostic yield of CTA and DSA were compared by McNemar's test. Results: 24 consecutive patients (11 men; median age 64 years) were included. CTA and DSA identified an active bleeding or a potential bleeding lesion in 92% (22 of 24 patients; 95% CI 72%–99%) and 29% (7 of 24 patients; 95% CI 12%–49%) of patients, respectively (p < 0.001). CTA and DSA identified an active bleeding in 42% (10 of 24; 95% CI 22%–63%) and 21% (5 of 24; 95% CI 7%–42%) of patients, respectively (p = 0.06). Conclusion: Due to the lower invasiveness and higher diagnostic yield CTA should be favored over DSA for the diagnosis of major OGIB.

  12. Computed tomography versus digital subtraction angiography for the diagnosis of obscure gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Wildgruber, Moritz; Wrede, Christian E.; Zorger, Niels; Müller-Wille, René; Hamer, Okka W.; Zeman, Florian; Stroszczynski, Christian; Heiss, Peter

    2017-01-01

    Purpose: The diagnostic yield of computed tomography angiography (CTA) compared to digital subtraction angiography (DSA) for major obscure gastrointestinal bleeding (OGIB) is not known. Aim of the study was to prospectively evaluate the diagnostic yield of CTA versus DSA for the diagnosis of major OGIB. Material and methods: The institutional review board approved the study and informed consent was obtained from each patient. Patients with major OGIB were prospectively enrolled to undergo both CTA and DSA. Two blinded radiologists each reviewed the CTA and DSA images retrospectively and independently. Contrast material extravasation into the gastrointestinal lumen was considered diagnostic for active bleeding. Primary end point of the study was the diagnostic yield, defined as the frequency a technique identified an active bleeding or a potential bleeding lesion. The diagnostic yield of CTA and DSA were compared by McNemar's test. Results: 24 consecutive patients (11 men; median age 64 years) were included. CTA and DSA identified an active bleeding or a potential bleeding lesion in 92% (22 of 24 patients; 95% CI 72%–99%) and 29% (7 of 24 patients; 95% CI 12%–49%) of patients, respectively (p < 0.001). CTA and DSA identified an active bleeding in 42% (10 of 24; 95% CI 22%–63%) and 21% (5 of 24; 95% CI 7%–42%) of patients, respectively (p = 0.06). Conclusion: Due to the lower invasiveness and higher diagnostic yield CTA should be favored over DSA for the diagnosis of major OGIB.

  13. The comparative study on diagnostic validity of cerebral aneurysm by computed tomography angiography versus digital subtraction angiography after subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Masih Saboori

    2011-01-01

    Full Text Available Background: In order to declare the preoperative diagnostic value of brain aneurysms, two radiological modalities, computed tomographic angiography and digital subtraction angiography were compared. Methods: In this descriptive analytic study, diagnostic value of computed tomographic angiography (CTA was com-pared with digital subtraction angiography (DSA. Sensitivity, specificity, positive and negative predictive values were calculated and compared between the two modalities. All data were analyzed with SPSS software, version 16. Results: Mean age of patients was 49.5 ± 9.13 years. 57.9 % of subjects were female. CTA showed 89% sensitivity and 100% specificity whereas DSA demonstrated 74% sensitivity and 100% specificity. Positive predictive value of both methods was 100%, but negative predictive value of CTA and DSA was 85% and 69%, respectively. Conclusions: Based on our data, CTA is a valuable diagnostic modality for detection of brain aneurysm and su-barachnoid hemorrhage.

  14. Image postprocessing of aortic CTA and MRA; Aktuelle Bildnachverarbeitung der aortalen CTA und MRA

    Energy Technology Data Exchange (ETDEWEB)

    Tengg-Kobligk, H. von; Weber, T.F.; Rengier, F.; Kauczor, H.U. [Deutsches Krebsforschungszentrum (DKFZ), Abteilung Radiologie E010, Heidelberg (Germany); Boeckler, D. [Ruprecht-Karls-Universitaet Heidelberg, Klinik fuer Gefaesschirurgie, vaskulaere und endovaskulaere Chrirurgie, Heidelberg (Germany); Schumacher, H. [Klinikum der Stadt Hanau, Klinik fuer Gefaesschirurgie, Hanau (Germany)

    2007-11-15

    Multiplanar reformation (MPR) is the most relevant tool for patient selection and precise procedural planning and also for analyzing postinterventional complications. Curved MPR is used primarily for semiautomated or completely automated calculation of the centerline of the vascular lumen and to estimate the orthogonal vessel diameter and longitudinal extent. Reproducible and accurate measurement of complex pathologies and courses of vessels extends the range of diagnostic radiology. Contemporary scanner consoles allow automated processing of maximum intensity projections (MIP) and standard MPR and their storage in PACS. To improve patient selection, procedural planning, root-cause analysis postoperatively for assessment of treatment effects and to make better communication of findings to nonradiologists possible, volume rendering techniques (VRT) are a beneficial adjunct to source images. With current algorithms semiautomated segmentation is satisfactory for vessels and bones, but not for low-contrast structures (soft tissues), which still need to be segmented manually. In general, isotropic CT source data are preferable to MR images, which are often anisotropic. In many European countries image postprocessing is still not adequately reimbursed although the doctors making referrals often specifically and emphatically demand 3D visualization and measurements in daily practice. (orig.) [German] Die multiplanare Reformatierung (MPR) der Bilddaten aortaler CTA und MRA ist die wichtigste Rekonstruktionsmethode im Hinblick auf eine differenzierte Therapieentscheidung und die praeoperative Therapieplanung sowie die Beschreibung postoperativer Komplikationen. Die gekruemmte MPR wird semiautomatisch bzw. vollstaendig automatisch als Centerline im Gefaesslumen berechnet und fuer die Bestimmung des orthogonalen Durchmessers und der Laengsausdehnung der Pathologie verwendet. Eine reproduzierbar exakte Ausmessung komplexer Pathologien und Gefaesslaengsverlaeufe erweitert das

  15. Meeting of the ITER CTA Project Board

    International Nuclear Information System (INIS)

    Vlasenkov, V.

    2001-01-01

    The meeting of the ITER CTA Project Board took place in Toronto, Canada on 7 November 2001, on the occasion of the first Negotiations Meeting. Twelve participants, representing PB members and experts from Canada, the EU, Japan, the RF and the international Team (IT), attended the meeting chaired by Acad. E. Velikhov. Discussions on the preliminary work programme for the CTA and organizational arrangements for the IT and PT took most of the time of the meeting. The Project Board approved the preliminary work programme as presented by the IT leader

  16. ITER CTA newsletter. No. 12, September 2002

    International Nuclear Information System (INIS)

    2002-11-01

    This ITER CTA newsletter issue comprises information about two ITER meetings: The meeting of the ITER CTA Project Board (PB), which took place in Toronto, Canada on 16 September 2002 on the occasion of the fifth Negotiations Meeting (N-5) and the second meeting of the International Tokamak Physics Activity (ITPA) coordinating committee, consisting of representatives from the ITPA participants and the topical physics group chairs and co-chairs, which was held at GA Technologies, San Diego, USA on 1-2 March 2002

  17. Imaging anatomy of dorsal pancreatic artery in patients with diabetes: a comparative study between CTA and DSA

    International Nuclear Information System (INIS)

    Lin Yuning; Li Hui; Yang Xizhang; Chen Ziqian; Tan Jianming; Zhong Qun; Yang Li; Wu Zhixian; Li Huimin; Huang Yisheng

    2011-01-01

    Objective: To investigate the clinical value of 64-section CT angiography (CTA) in detecting the origin of dorsal pancreatic artery (DPA). Methods: Ninety-seven consecutive patients with diabetes received transcatheter infusion of autologous bone marrow-derived stem cell transplantation into DPA. Abdominal CTA was performed in 42 patients before angiography. Celiac trunk, splenic, common hepatic and superior mesenteric arteries were reconstructed in order to locate the origin and traveling course of DPA. A routine angiography of both celiac and superior mesenteric arteries was performed for the demonstration of DPA. Further angiography of splenic and gastroduodenal arteries was carried out if necessary. Taking DSA images as the reference standard, the sensitivity, specificity and accuracy of CTA for DPA detection were calculated. Results: DPA was the main supply artery of pancreas in 85.7% patients (36/42). CTA demonstrated the origin of DPA in 35 cases, although one of which was confirmed to be misjudged (false positive). In seven cases CTA could not demonstrate DPA, and DSA proved that 2 of them was misjudged (false negative). The sensitivity,specificity and accuracy of CTA for DPA detection were 94.4%, 83.3% and 92.9%, respectively. Conclusion: 64-section CTA can accurately detect the origin of main supply artery of pancreas, which is of great value in guiding the interventional procedure for pancreatic diseases. (authors)

  18. Final ITER CTA project board meeting

    International Nuclear Information System (INIS)

    Vlasenkov, V.

    2003-01-01

    The final ITER CTA Project Board Meeting (PB) took place in Barcelona, Spain on 8 December 2002. The PB took notes of the comments concerning the status of the International Team and the Participants Teams, including Dr. Aymar's report 'From ITER to a FUSION Power Reactor' and the assessment of the ITER project cost estimate

  19. Artificial intelligence for the CTA Observatory scheduler

    Science.gov (United States)

    Colomé, Josep; Colomer, Pau; Campreciós, Jordi; Coiffard, Thierry; de Oña, Emma; Pedaletti, Giovanna; Torres, Diego F.; Garcia-Piquer, Alvaro

    2014-08-01

    The Cherenkov Telescope Array (CTA) project will be the next generation ground-based very high energy gamma-ray instrument. The success of the precursor projects (i.e., HESS, MAGIC, VERITAS) motivated the construction of this large infrastructure that is included in the roadmap of the ESFRI projects since 2008. CTA is planned to start the construction phase in 2015 and will consist of two arrays of Cherenkov telescopes operated as a proposal-driven open observatory. Two sites are foreseen at the southern and northern hemispheres. The CTA observatory will handle several observation modes and will have to operate tens of telescopes with a highly efficient and reliable control. Thus, the CTA planning tool is a key element in the control layer for the optimization of the observatory time. The main purpose of the scheduler for CTA is the allocation of multiple tasks to one single array or to multiple sub-arrays of telescopes, while maximizing the scientific return of the facility and minimizing the operational costs. The scheduler considers long- and short-term varying conditions to optimize the prioritization of tasks. A short-term scheduler provides the system with the capability to adapt, in almost real-time, the selected task to the varying execution constraints (i.e., Targets of Opportunity, health or status of the system components, environment conditions). The scheduling procedure ensures that long-term planning decisions are correctly transferred to the short-term prioritization process for a suitable selection of the next task to execute on the array. In this contribution we present the constraints to CTA task scheduling that helped classifying it as a Flexible Job-Shop Problem case and finding its optimal solution based on Artificial Intelligence techniques. We describe the scheduler prototype that uses a Guarded Discrete Stochastic Neural Network (GDSN), for an easy representation of the possible long- and short-term planning solutions, and Constraint

  20. Removal of arterial wall calcifications in CT angiography by local subtraction

    International Nuclear Information System (INIS)

    Straten, Marcel van; Venema, Henk W.; Streekstra, Geert J.; Reekers, Jim A.; Heeten, Gerard J. den; Grimbergen, Cornelis A.

    2003-01-01

    CT Angiography (CTA) is an established technique for the minimally invasive imaging of arteries. The technique of maximum intensity projection (MIP) is often used to get a comprehensive overview of the vascular anatomy. On a MIP, however, arterial wall calcifications may hinder the visualization of the arterial lumen. These calcifications are in direct contact with the contrast-enhanced blood, which makes removal difficult. We present a local subtraction method for the automatic removal of these calcifications. In our approach a second CT scan has to be made, prior to contrast injection. The calcifications in both scans are registered prior to subtraction to compensate for displacements in between the two scans. Local subtraction results are compared with results obtained by thresholding. The method was tested in a phantom and with data from four patients. The phantom represented an artery with different types of stenosis. Data were used from patients for which CTA of the renal arteries was performed. For two patients the electrocardiogram (ECG) was recorded during the CTA examination, making retrospective cardiac gated reconstructions possible. Both the phantom and the patient study showed that the local subtraction method is capable of removing calcifications and visualizing the residual lumen. In the patient study it appeared that some artifacts remained for higher pitch values. We conclude that the local subtraction method is less subjective and more accurate than thresholding. Best results are obtained by use of a small pitch, at the expense of the volume covered during a single breath hold

  1. Automatic dipole subtraction

    International Nuclear Information System (INIS)

    Hasegawa, K.

    2008-01-01

    The Catani-Seymour dipole subtraction is a general procedure to treat infrared divergences in real emission processes at next-to-leading order in QCD. We automatized the procedure in a computer code. The code is useful especially for the processes with many parton legs. In this talk, we first explain the algorithm of the dipole subtraction and the whole structure of our code. After that we show the results for some processes where the infrared divergences of real emission processes are subtracted. (author)

  2. Meeting of the ITER CTA Project Board

    International Nuclear Information System (INIS)

    2001-01-01

    Full text: A preparatory meeting of the Co-ordinated Technical Activities (CTA) Project Board took place in Vienna on 16 July 2001. The Board Members of Canada, EU, Japan, RF and of the CTA International Team participated in the Meeting, which was chaired by Acad. E. Velikhov. The major item on the Meeting Agenda was the discussion of the scope of the CTA. In this discussion the following comments were expressed: One of the prime objectives during the CTA is to develop technical specifications for procurement of critical items (magnets, vacuum vessel, and buildings). It was noted that the discussions with potential suppliers should confirm manufacturing processes in details in order to explore possible schedule reduction strategies. Safety analysis and licensing preparation should proceed on all proposed sites up to the preferred site designation, to ensure the overall implementation schedule is minimized and to resolve major technical issues needed for licensing. Several R and D issues remain to be further developed during the CTA. Special attention should be given by the Participants to two areas: Diagnostics; Heating and Current Drive Systems. Arrangements for continuation of the ITER Physics Expert Groups activities should be provided. To this end a new framework, called International Tokamak Physics Activity, is being planned. The Board encouraged the Participants' Representatives in the Co-ordinating committee of this activity to support the preparation for urgent Topical Group Meetings. The Board agreed that the Design Authority will be invested in the International Team and that proposals for site specific design changes should be agreed upon by the International Team Leader before being studied in detail. The Meeting agreed on some arrangements which will remain from the EDA, namely the ITER EDA Council Office in Moscow as Office of the PB Chair, and the ITER Office located at the IAEA in Vienna as agreed by the IAEA. The Board recommended that effective

  3. ITER CTA newsletter. No. 11, August 2002

    International Nuclear Information System (INIS)

    2002-10-01

    This ITER CTA Newsletter issue includes conclusions of the Fusion Fast Track experts meeting held on 27 November 2001, which were presented to the European Research Council. The term 'Fast Track' has its origin in an initiative taken by the Belgian Presidency of the European Research Council to investigate whether it might be possible to accelerate the development of fusion, setting a goal for thermonuclear energy production with 20-30 years

  4. ITER CTA newsletter. No. 13, October 2002

    International Nuclear Information System (INIS)

    2002-11-01

    This ITER CTA newsletter issue comprises concise information about an ITER related meeting concerning the joint implementation of ITER - the fifth ITER Negotiations Meeting - which was held in Toronto, Canada, 19-20 September, 2002, and information about assessment of the possible ITER site in Clarington, Ontario, Canada, which was the subject of the first official stage of the Joint Assessment of Specific Sites (JASS) for the ITER Project. This assessment was completed just before the Fifth ITER Negotiations Meeting

  5. Meeting of the ITER CTA Project Board

    International Nuclear Information System (INIS)

    Vlasenkov, V.

    2002-01-01

    The meeting of the ITER CTA Project Board (PB) took place in Toronto, Canada on 16 September 2002 on the occasion of the fifth Negotiations Meeting (N-5). Thirteen participants, PB members and experts from Canada, EU, Japan, RF and the International Team (IT) attended the meeting chaired by Acad. E. Velikhov. PB heard progress reports of the participating parties and the comments concerning the status of participants team (PT) and the IT were presented

  6. Mast cells contribute to the mucosal adjuvant effect of CTA1-DD after IgG-complex formation.

    Science.gov (United States)

    Fang, Yu; Larsson, Lisa; Mattsson, Johan; Lycke, Nils; Xiang, Zou

    2010-09-01

    Mast cell activation is one of the most dramatic immune-mediated responses the body can encounter. In the worst scenario (i.e., anaphylaxis), this response is fatal. However, the importance of mast cells as initiators and effectors of both innate and adaptive immunity in healthy individuals has recently been appreciated. It was reported that mast cell activation can be used as an adjuvant to promote Ag-specific humoral immune responses upon vaccination. In this study, we have used a clinically relevant mucosal adjuvant, cholera toxin A1 subunit (CTA1)-DD, which is a fusion protein composed of CTA1, the ADP-ribosylating part of cholera toxin, and DD, two Ig-binding domains derived from Staphylococcus aureus protein A. CTA1-DD in combination with polyclonal IgG induced degranulation and production of TNF-alpha from mouse mast cells. Furthermore, CTA1-DD and polyclonal IgG complex induced mast cell degranulation in mouse skin tissue and nasal mucosa. We also found that intranasal immunization with hapten (4-hydroxy-3-nitrophenyl) acetyl (NP) coupled to chicken gammaglobulin admixed with CTA1-DD complexed with polyclonal IgG greatly enhanced serum IgG anti-NP Ab responses and stimulated higher numbers of NP-specific plasma cells in the bone marrow as compared with that observed in mice immunized with NP-chicken gammaglobulin with CTA1-DD alone. This CTA1-DD/IgG complex-mediated enhancement was mast cell dependent because it was absent in mast cell-deficient Kit(W-sh/W-sh) mice. In conclusion, our data suggest that a clinically relevant adjuvant, CTA1-DD, exerts additional augmenting effects through activation of mucosal mast cells, clearly demonstrating that mast cells could be further exploited for improving the efficacy of mucosal vaccines.

  7. Digital subtraction angiography system evaluation with phantoms

    International Nuclear Information System (INIS)

    Wenstrup, R.S.; Sweeney, K.P.; Scholz, F.J.

    1985-01-01

    Advances in digital subtraction angiography imaging demonstrate the need for critical evaluation of the performance of digital subtraction equipment. The design of a phantom set for noninvasive assessment of the imaging quality of digital subtraction equipment is described; components include a remotely controlled transport system and individual patterns to evaluate the contrast and detail properties of the image intensifier, low-contrast sensitivity and resolution of the system, geometric distortion of image, linearity, mechanical and electronic stability of equipment, and effects of bone and bowel gas on iodine perception. The performance of an add-on digital radiographic system is presented, along with radiation exposure levels at the image intensifier for a range of radiographic techniques

  8. Dual energy CTA of the supraaortic arteries: Technical improvements with a novel dual source CT system

    Energy Technology Data Exchange (ETDEWEB)

    Lell, Michael M., E-mail: Michael.lell@uk-erlangen.de [Department of Radiology, University Erlangen, Maximiliansplatz 1, 91054 Erlangen (Germany); Hinkmann, Fabian [Department of Radiology, University Erlangen, Maximiliansplatz 1, 91054 Erlangen (Germany); Nkenke, Emeka [Department of Maxillofacial Surgery, University Erlangen (Germany); Schmidt, Bernhard [Bayer-Schering Healthcare, Berlin (Germany); Seidensticker, Peter [Siemens Healthcare, CT-Division, Forchheim (Germany); Kalender, Willi A. [Institute of Medical Physics, University Erlangen (Germany); Uder, Michael [Department of Radiology, University Erlangen, Maximiliansplatz 1, 91054 Erlangen (Germany); Achenbach, Stephan [Department of Cardiology, University Erlangen (Germany)

    2010-11-15

    Objectives: Computed tomography angiography (CTA) is a well-accepted imaging modality to evaluate the supraaortic vessels. Initial reports have suggested that dual energy CTA (DE-CTA) can enhance diagnosis by creating bone-free data sets, which can be visualized in 3D, but a number of limitations of this technique have also been addressed. We sought to describe the performance of DE-CTA of the supraaortic vessels with a novel dual source CT system with special emphasis on image quality and post-processing related artifacts. Materials and methods: Thirty-three patients underwent carotid CT angiography on a second generation dual source CT system. Simultaneous acquisitions of 100 and 140 kV data sets in arterial phase were performed. Two examiners evaluated overall bone suppression with a 3-point scale (1 = poor; 3 = excellent) and image quality regarding integrity of the vessel lumen of different vessel segments (n = 26) with a 5-point scale (1 = poor; 5 = excellent), CTA source data served as the reference. Results: Excellent bone suppression could be achieved in the head and neck. Only minor bone remnants occurred, mean score for bone removal was 2.9. Mean score for vessel integrity was 4.3. Eight hundred fifty-seven vessel segments could be evaluated. Six hundred thirty-five segments (74%) showed no lumen alteration, 65 segments (7.6%) lumen alterations <10%, 27 segments (3.1%) lumen alterations >10% resulting in a total luminal reduction <50%, 17 segments (2%) lumen alterations of more than 10% resulting in a total luminal reduction >50%, and 113 segments (13.2%) showed a gap in the vessel course (100% total lumen reduction). Artificial gaps of the vessel lumen occurred in 28 vessel segments due to artifacts caused by dental hardware and in all but one (65) ophthalmic arteries. Conclusions: Excellent bone suppression could be achieved, DE imaging with 100 and 140 kV lead to improved image quality and vessel integrity in the shoulder region than previously

  9. CTA Contribution by Evaluation of Treatment AAA

    International Nuclear Information System (INIS)

    Mikulas, J.; Majercik, M.; Klepanec, A.; Balazs, T.; Bazik, R.; Vulev, I.

    2010-01-01

    Over the past decade, the EVAR (Endovascular aortic aneurysm repair) became an accepted treatment of abdominal aortic aneurysms (AAA) as compared with the radical open surgical treatment. Due to the latest generation of stents, 60% of infra renal AAA can be treated by the endovascular method or even percutaneously, without any surgical procedure, and only under the local anesthesia. We retrospectively evaluated the findings of patients following elective EVAR who underwent CTA examination immediately after the procedure and three months after the procedure, for the period from June 2009 to February 2010 (9 months).

  10. ITER CTA newsletter. No. 16, January 2003

    International Nuclear Information System (INIS)

    2003-04-01

    This ITER CTA newsletter contains information about some ITER related activities including ITER transitional arrangements (ITA) which will start on 1 January 2003, the USA rejoining ITER and People's Republic of China joining ITER, the visit of Mr. J. Koizumi, Prime Minister of Japan, to Kurchatov Institute, Moscow, Russian Federation on 11 January 2003, and the most recent meeting of the Scrape-Off Layer (SOL) and Divertor Physics Group of the International Tokamak Physics Activity (ITPA), which was held in Lausanne, Switzerland, on October 21-23, 2002 at the CRPP/EFL laboratory

  11. Meeting of the ITER CTA Project Board

    International Nuclear Information System (INIS)

    Vlasenkov, V.

    2002-01-01

    The meeting of the ITER co-ordinated technical activities project board took place in Tokyo, Japan, on 21 January 2002, coinciding with the second Negotiators meeting (N2). Twelve participants, project board members and experts from Canada, European Union, the Russian Federation and the international team attended the meeting. The project board agreed to provide an R and D plan by June 2002, to be linked with the procurement allocation, for the period following the CTA. The ITER International Team Leader developed a proposal on establishing the working groups for drafting technical specifications for the most urgent procurement items

  12. Meeting of the ITER CTA project board

    International Nuclear Information System (INIS)

    Vlasenkov, V.

    2002-01-01

    This is information about meeting of the ITER CTA project board, which took place in Moscow, Russian Federation on 22 April 2002 on the occasion of the Third Negotiators Meeting (N3). Thirteen participants, representing PB members and experts from Canada (CA), the European Union (EU), Japan(JA), the Russian federation (RF) and the International Team (IT) attended the meeting chaired by Acad. E. Velikhov. The Project Board took note of the comments made concerning the status of the Participants Teams(PTs)

  13. Helical CT for emergency patients with cerebrovascular diseases. Diagnosis of cerebral aneurysms with subarachnoid hemorrhage (SAH) by three-dimensional CT angiography (3D-CTA)

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Satoh, Naoki; Kobayashi, Touru; Kodama, Namio; Nakano, Masayuki; Watanabe, Youichi; Fujii, Masayuki

    1996-01-01

    Recently, the usefulness of three-dimensional CT angiography (3D-CTA) using helical CT has been reported. Although 3D-CTA has been applied for neurosurgical diseases, especially for surgical planning, it has not done for emergency patients because of the long time required for image reconstruction and location of a helical CT scanner. We studied emergency patients with SAH, and compared the 3D-CTA with angiography and surgical findings, using TOSHIBA X vigor. Twenty-two patients with SAH were evaluated. The helical CT was performed for 55 seconds with a bolus injection of 90 ml non-ionic, iodinated contrast medium at a rate of 3 ml/sec with a delay of 20 sec. Angiography was carried out immediately after the helical CT. Eighteen of 22 cases were operated on urgently. We were able to create the 3D-CTA in about 7 minutes, and diagnose aneurysms by the 3D-CTA before angiography. The 3D-CTA was able to demonstrate 30 of 31 aneurysms including 9 unruptured aneurysms. An unruptured internal carotid-posterior communicating artery aneurysm 1.3 mm in diameter and associated with a ruptured aneurysm was not detected by either the 3D-CTA or angiography. On the other hand, an unruptured Acom aneurysm 0.8 mm in diameter and associated with a ruptured aneurysm could be detected by the: 3D-CTA, but not by angiography. The 3D-CTA gave us useful information concerning the anatomical relationship of the aneurysm, its neck and parent artery, and the surrounding branches. There were no complications or side effects associated with the helical CT scan. Although the 3D-CTA requires further development of visualization of small arteries less than 1 mm in diameter, such as perforating arteries, subtraction technique of bony structure, and a method for checking cervical arteries, it is useful for diagnosis of emergency patients with SAH and urgent operations. We believe that an operation might be performed by only the 3D-CTA without the angiography in the near future. (author)

  14. Helical CT for emergency patients with cerebrovascular diseases. Diagnosis of cerebral aneurysms with subarachnoid hemorrhage (SAH) by three-dimensional CT angiography (3D-CTA)

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Masato; Satoh, Naoki; Kobayashi, Touru; Kodama, Namio; Nakano, Masayuki; Watanabe, Youichi; Fujii, Masayuki [Fukushima Medical School (Japan)

    1996-05-01

    Recently, the usefulness of three-dimensional CT angiography (3D-CTA) using helical CT has been reported. Although 3D-CTA has been applied for neurosurgical diseases, especially for surgical planning, it has not done for emergency patients because of the long time required for image reconstruction and location of a helical CT scanner. We studied emergency patients with SAH, and compared the 3D-CTA with angiography and surgical findings, using TOSHIBA X vigor. Twenty-two patients with SAH were evaluated. The helical CT was performed for 55 seconds with a bolus injection of 90 ml non-ionic, iodinated contrast medium at a rate of 3 ml/sec with a delay of 20 sec. Angiography was carried out immediately after the helical CT. Eighteen of 22 cases were operated on urgently. We were able to create the 3D-CTA in about 7 minutes, and diagnose aneurysms by the 3D-CTA before angiography. The 3D-CTA was able to demonstrate 30 of 31 aneurysms including 9 unruptured aneurysms. An unruptured internal carotid-posterior communicating artery aneurysm 1.3 mm in diameter and associated with a ruptured aneurysm was not detected by either the 3D-CTA or angiography. On the other hand, an unruptured Acom aneurysm 0.8 mm in diameter and associated with a ruptured aneurysm could be detected by the: 3D-CTA, but not by angiography. The 3D-CTA gave us useful information concerning the anatomical relationship of the aneurysm, its neck and parent artery, and the surrounding branches. There were no complications or side effects associated with the helical CT scan. Although the 3D-CTA requires further development of visualization of small arteries less than 1 mm in diameter, such as perforating arteries, subtraction technique of bony structure, and a method for checking cervical arteries, it is useful for diagnosis of emergency patients with SAH and urgent operations. We believe that an operation might be performed by only the 3D-CTA without the angiography in the near future. (author)

  15. Detection of aneurysms in subarachnoidal hemorrhage - CT-angiography versus digital subtraction angiography

    International Nuclear Information System (INIS)

    Roehnert, W.; Haenig, V.; Hietschold, V.; Abolmaali, N.

    1998-01-01

    Purpose: The value of CT-angiography (CT-A) for the visualization of intracranial aneurysms was more closely defined by comparison with digital subtraction angiography (DSA). Methods: Over a period of 18 months a total of 106 patients in whom a subarachnoidal hemorrhage had been detected on native CT were examined in parallel by spiral CT and DSA. CT-angiography was performed under standardized parameters and included processing with 3D surface reconstructions. Results: In 64 patients (60.4%) at total of 72 aneurysms were detected. In four cases (6.2%) there were two and in two cases (3.1%) even three aneurysms. The findings of DSA and CTA agreed in 98 cases (92.5%). In four patients (3.8%) a false negative results was obtained in CTA and the initial DSA. Conclusions: Digital subtraction angiography must still be considered as the gold standard in the diagnosis of cerebral aneurysms. On account of its excellent spatial delineation of aneurysms and possibilities for exact measurements, CT-angiography represents a valuable, supplementary method - in some cases also an alternative method - to digital subtraction angiography. (orig.) [de

  16. Comparison of CT angiography and digital subtraction angiography in the evaluation of intracranial aneurysmal neck

    International Nuclear Information System (INIS)

    Kim, Yoo Kyung; Baik, Seung Kug; Shin, Mi Jeong; Choi, Han Yong

    2001-01-01

    To compare the usefulness of three-dimensional multislice CT angiography(CTA) and digital subtraction angiography (DSA) in the evaluation of intracranial aneurysmal neck. Nineteen patients with intracranial aneurysm (23 cases) underwent DSA and subsequent CTA. Using a multislice CT scanner and the SSD(shaded surface display) technique, clipping, cutting and the MPR technique, three-dimensional images were obtained. These were (a) external, (b) internal, from the direction of the parent artery, (c) internal, from the direction of the aneurysmal dome, and (d) an aneurysmal cutting image. The CTA findings were retrospectively compared with the DSA images. Twenty aneurysms were small and three were large. In eleven cases aneurysm neck was small, in nine it was wide, and in three it was relatively wide. For aneurysmal neck evaluation, CTA was superior to DSA in six of nine wide-neck aneurysms and all three large-sized wide-neck aneurysms. In small neck aneurysms 8 of 11 cases and in relatively wide neck all 3 cases showed similarly good images by both modalities. Of the 23 cases demonstrated by four different images, 14 cases showed the best image in internal image from parent artery direction and 6 cases showed similarly good image in both aneurysmal cutting image and internal image from parent artery direction. In the evaluation of wide neck aneurysms, 7 of 9 cases showed the best image at internal image from parent artery direction, compared with other three different images. In two cases of aneurysms, calcification was visible in the aneurysmal wall, so it was difficult to evaluate the aneurysmal neck. CTA was superior to DSA in the evaluating the intracranial aneurysmal neck. CTA maybe an additional available modality to evaluate the aneurysmal neck which is difficult to detect by the DSA. And the information of intracranial aneurysmal neck through CTA will be of value in surgical and endovascular treatment

  17. Automating dipole subtraction

    International Nuclear Information System (INIS)

    Hasegawa, K.; Moch, S.; Uwer, P.

    2008-07-01

    We report on automating the Catani-Seymour dipole subtraction which is a general procedure to treat infrared divergences in real emission processes at next-to-leading order in QCD. The automatization rests on three essential steps: the creation of the dipole terms, the calculation of the color linked squared Born matrix elements, and the evaluation of different helicity amplitudes. The routines have been tested for a number of complex processes, such as the real emission process gg→t anti tggg. (orig.)

  18. Automating dipole subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, K.; Moch, S. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Uwer, P. [Karlsruhe Univ. (T.H.) (Germany). Inst. fuer Theoretische Teilchenphysik

    2008-07-15

    We report on automating the Catani-Seymour dipole subtraction which is a general procedure to treat infrared divergences in real emission processes at next-to-leading order in QCD. The automatization rests on three essential steps: the creation of the dipole terms, the calculation of the color linked squared Born matrix elements, and the evaluation of different helicity amplitudes. The routines have been tested for a number of complex processes, such as the real emission process gg{yields}t anti tggg. (orig.)

  19. Intraarterial digital subtraction angiography

    International Nuclear Information System (INIS)

    Davis, P.C.

    1987-01-01

    Digital subtraction angiography (DSA) refers to a radiographic technique of amplifying low levels of contrast from intravascular iodine into an acceptable image of vascular anatomy. Initial enthusiasm suggested that DSA using intravenous injections (IV-DSA) would eliminate most conventional film-screen angiographic studies. It was soon apparent, however, that IV-DSA examinations were often compromised in those patients who most needed a less invasive study. Indeed, only a 70 to 85 percent accuracy rate was achieved with IV-DSA, primarily due to motion artifact, poor cardiac output, overlap of pertinent vessels, and inability to resolve smaller vessels

  20. Colourful FKS subtraction

    CERN Document Server

    Frixione, Stefano

    2011-01-01

    I formulate in a colour-friendly way the FKS method for the computation of QCD cross sections at the next-to-leading order accuracy. This is achieved through the definition of subtraction terms for squared matrix elements, constructed with single colour-dressed or pairs of colour-ordered amplitudes. The latter approach relies on the use of colour flows, is exact to all orders in $N$, and is thus particularly suited to being organized as a systematic expansion in 1/N.

  1. Digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Ludwig, J.W.; Eikelboom, B.C.; Van Schaik, C.C.; Taams, A.J.; Teeuwen, C.

    1985-01-01

    Besides the non-invasive techniques, angiography remains essential. The disadvantages of angiography are the complexity of the procedure and the possibility of complications. Digital subtraction angiography (DSA) is a considerable improvement in the examination of vessels. In DSA, subtraction combined with enhancement of the signals allows the use of intravenous injection to obtain good images of the arteries. However, when the contrast material is supplied intravenously, a rather large amount of contrast material is necessary to obtain images of good quality. Quantities of 30-40 cc of contrast material are required. The advantage of the intravenous injection of contrast material rather than the use of a catheter to deliver the contrast material in loco is that it is almost non-invasive thus circumventing the complications caused by catheter manipulation in the arterial system. This makes it possible to apply this method on an out-patient basis. DSA can also be applied with intra-arterial selective injection of the contrast material. In this case, the strong enhancement with DSA allows the use of a small quantity of contrast material while still obtaining images of the vessels with good contrast definition

  2. Evaluation of sacroiliitis: contrast-enhanced MRI with subtraction technique

    Energy Technology Data Exchange (ETDEWEB)

    Algin, Oktay; Gokalp, Gokhan; Baran, Bulent; Ocakoglu, Gokhan; Yazici, Zeynep [Uludag University, Medical Faculty, Department of Radiology, Gorukle, Bursa (Turkey)

    2009-10-15

    The purpose of the study was to investigate the diagnostic value of contrast-enhanced MRI using the subtraction technique in the detection of active sacroiliitis. Magnetic resonance imaging was performed in 8 asymptomatic volunteers and 50 patients with clinically suspected active sacroiliitis. On precontrast MR images, T1-weighted spin-echo images with and without fat saturation (T1WFS and T1W), STIR and 3D-FLASH images with fat saturation were obtained in the semicoronal plane using a 1.5 Tesla imager. Postcontrast MRI was performed using the same T1WFS sequence as before contrast injection for all volunteers and patients. Postcontrast images were subtracted from fat-suppressed precontrast images. Enhancement within the joint space and bone marrow was considered to demonstrate active sacroiliitis. In 50 patients (100 sacroiliac joints [SIJs]), 40 (76 SIJs) were considered to have active sacroiliitis based on MR images. Bone marrow edema was present in 33 patients (62 SIJs) on STIR images. Routine MRI allowed identification of contrast enhancement in SIJs on postcontrast T1WFS images in 31 patients (49 SIJs). Contrast enhancement was observed in 40 patients (76 SIJs) who were examined by MRI using the subtraction technique. Contrast enhancement was significantly more conspicuous on subtraction images than on non-subtracted postcontrast T1WFS images (Mann-Whitney U test, p<0.001). Contrast-enhanced MRI with subtraction technique may be useful for early detection of active sacroiliitis. (orig.)

  3. A comparison of subtracted images from dental subtraction programs

    International Nuclear Information System (INIS)

    Han, Won Jeong

    2002-01-01

    To compare the standard deviation of gray levels on digital subtracted images obtained by different dental subtraction programs. Paired periapical films were taken at the lower premolar and molar areas of the phantoms involving human mandible. The bite registration group used Rinn XCP equipment and bite registration material, based on polyvinyl siloxane, for standardization. The no bite registration group used only Rinn XCP equipment. The periapical film images were digitized at 1200 dpi resolution and 256 gray levels by a flat bed scanner with transparency unit. Dental digital subtraction programs used for this study were Subtractor (Biomedisys Co., Korea) and Emago (Oral Diagnostic Systems, The Netherlands). To measure the similarities between the subtracted images, the standard deviations of the gray levels were obtained using a histogram of subtracted images, which were then analyzed statistically. Subtracted images obtained by using the Emago program without manual selection of corresponding points showed the lowest standard deviation of gray levels (p<0.01). And the standard deviation of gray levels was lower in subtracted images in the group of a bite registration than in the group of no use of bite registration (p<0.01). Digital radiographic subtraction without manual selection of reference points was found to be a convenient and superior method.

  4. Digital subtraction angiography

    International Nuclear Information System (INIS)

    Gmelin, E.; Arlart, I.P.

    1987-01-01

    The introduction explains the technical and physical fundamentals of digital radiography, the principles of digital subtraction, and the various filtering methods. The authors then define the requirements to be met by a DSA equipment in terms of technical components and operational performance. A very extensive chapter deals with the indications supporting intravenous or intraarterial DSA and compares the two methods, showing advantages and drawbacks with respect to practical results. Another chapter discusses the applications of DSA for cardiological diagnostics, as e.g. imaging of the coronary arteries or arterial bypasses, and explains the densitometric and planimetric evaluation of the coronary functional processes. The book also discusses less customary applications of DSA such as the sialography or dacryocystography, as well as angiologic examinations in children. The limits of the DSA methods are discussed in the last chapter, together with aspects such as the radiation exposure of the patient, and cost-benefit analyses, and potential future improvements. With 204 figs., 44 tabs [de

  5. Digital subtraction angiography

    International Nuclear Information System (INIS)

    Neuwirth, J. Jr.; Bohutova, J.

    1987-01-01

    The quality of radiodiagnostic methods to a great extent depends on the quality of the resulting image. The basic technical principles are summed up of the different parts of digital subtraction angiography apparatus and of methods of improving the image. The instrument is based on a videochain consisting of an X-ray tube, an intensifier of the radiographic image, optical parts, a video camera, an analog-to-digital converter and a computer. The main advantage of the digitally processed image is the possibility of optimizing the image into a form which will contain the biggest amount of diagnostically valuable information. Described are the mathematical operations for improving the digital image: spatial filtration, pixel shift, time filtration, image integration, time interval differentation and matched filtering. (M.D.). 8 refs., 3 figs

  6. Added value of multiphase CTA imaging for thrombus perviousness assessment

    Energy Technology Data Exchange (ETDEWEB)

    Santos, E.M.M. [Academic Medical Center, Department of Biomedical Engineering and Physics, Amsterdam (Netherlands); Erasmus Medical Center, Department of Medical Informatics, Rotterdam (Netherlands); D' Esterre, C.D.; Najm, M.; Goyal, M.; Demchuk, A.M.; Menon, B.K. [University of Calgary, Departments of Neurosciences, Radiology and Community Health Sciences, Calgary (Canada); Treurniet, K.M.; Majoie, C.B. [Academic Medical Center, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Niessen, W.J. [Erasmus Medical Center, Department of Medical Informatics, Rotterdam (Netherlands); Delft University of Technology, Faculty of Applied Sciences, Delft (Netherlands); Marquering, H.A. [Academic Medical Center, Department of Biomedical Engineering and Physics, Amsterdam (Netherlands); Academic Medical Center, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Mandzia, Jennifer; Fainardi, Enrico; Rubiera, Marta; Khaw, Alexander V.; Zini, Andrea; Shankar, JJ.; Collaboration: PRove-IT investigators

    2018-01-15

    Thrombus perviousness has been associated with favorable functional outcome in acute ischemic stroke (AIS) patients. Measuring thrombus perviousness on CTA may be suboptimal due to potential delay in contrast agent arrival in occluded arteries at the moment of imaging. Dynamic sequences acquired over time can potentially overcome this issue. We investigate if dynamic CTA has added value in assessing thrombus perviousness. Prospectively collected image data of AIS patients with proven occlusion of the anterior or posterior circulation with thin-slice multi-phase CTA (MCTA) and non-contrast CT were co-registered (n = 221). Thrombus attenuation increase (TAI; a perviousness measure) was measured for the arterial, venous, and delayed phase of the MCTA and time-invariant CTAs (TiCTA). Associations with favorable clinical outcome (90-day mRS ≤ 2) were assessed using univariate and multivariable regressions and calculating areas under receiver operating curves (AUC). TAI determined from the arterial phase CTA was superior in the association with favorable outcome with OR = 1.21 per 10 HU increase (95%CI 1.04-1.41, AUC 0.62, p = 0.014) compared to any other phase (venous 1.14(95%CI 1.01-1.30, AUC 0.58, p = 0.033), delayed 1.046(95%CI 0.919-1.19, AUC 0.53, p = 0.50)), and TiCTA 1.15(95%CI 1.02-1.30, AUC 0.60, p = 0.022). In the multivariable model, only TAI on arterial phase was significantly associated with favorable outcome (aOR 1.59, 95%CI 1.04-2.43, p = 0.032). Association between TAI with functional outcome was optimal on arterial-phase CTA such that dynamic CTA imaging has no additional benefits in current thrombus perviousness assessment, thereby suggesting that the delay of contrast arrival at the clot is a key variable for patient functional outcome. (orig.)

  7. Automated bone removal in CT angiography: Comparison of methods based on single energy and dual energy scans

    International Nuclear Information System (INIS)

    Straten, Marcel van; Schaap, Michiel; Dijkshoorn, Marcel L.; Greuter, Marcel J.; Lugt, Aad van der; Krestin, Gabriel P.; Niessen, Wiro J.

    2011-01-01

    Purpose: To evaluate dual energy based methods for bone removal in computed tomography angiography (CTA) images and compare these with single energy based methods that use an additional, nonenhanced, CT scan. Methods: Four different bone removal methods were applied to CT scans of an anthropomorphic thorax phantom, acquired with a second generation dual source CT scanner. The methods differed by the way information on the presence of bone was obtained (either by using an additional, nonenhanced scan or by scanning with two tube voltages at the same time) and by the way the bone was removed from the CTA images (either by masking or subtracting the bone). The phantom contained parts which mimic vessels of various diameters in direct contact with bone. Both a quantitative and qualitative analysis of image quality after bone removal was performed. Image quality was quantified by the contrast-to-noise ratio (CNR) normalized to the square root of the dose (CNRD). At locations where vessels touch bone, the quality of the bone removal and the vessel preservation were visually assessed. The dual energy based methods were assessed with and without the addition of a 0.4 mm tin filter to the high voltage x-ray tube filtration. For each bone removal method, the dose required to obtain a certain CNR after bone removal was compared with the dose of a reference scan with the same CNR but without automated bone removal. The CNRD value of the reference scan was maximized by choosing the lowest tube voltage available. Results: All methods removed the bone completely. CNRD values were higher for the masking based methods than for the subtraction based methods. Single energy based methods had a higher CNRD value than the corresponding dual energy based methods. For the subtraction based dual energy method, tin filtration improved the CNRD value with approximately 50%. For the masking based dual energy method, it was easier to differentiate between iodine and bone when tin filtration

  8. Background subtraction theory and practice

    CERN Document Server

    Elgammal, Ahmed

    2014-01-01

    Background subtraction is a widely used concept for detection of moving objects in videos. In the last two decades there has been a lot of development in designing algorithms for background subtraction, as well as wide use of these algorithms in various important applications, such as visual surveillance, sports video analysis, motion capture, etc. Various statistical approaches have been proposed to model scene backgrounds. The concept of background subtraction also has been extended to detect objects from videos captured from moving cameras. This book reviews the concept and practice of back

  9. Automatic aortic root segmentation in CTA whole-body dataset

    Science.gov (United States)

    Gao, Xinpei; Kitslaar, Pieter H.; Scholte, Arthur J. H. A.; Lelieveldt, Boudewijn P. F.; Dijkstra, Jouke; Reiber, Johan H. C.

    2016-03-01

    Trans-catheter aortic valve replacement (TAVR) is an evolving technique for patients with serious aortic stenosis disease. Typically, in this application a CTA data set is obtained of the patient's arterial system from the subclavian artery to the femoral arteries, to evaluate the quality of the vascular access route and analyze the aortic root to determine if and which prosthesis should be used. In this paper, we concentrate on the automated segmentation of the aortic root. The purpose of this study was to automatically segment the aortic root in computed tomography angiography (CTA) datasets to support TAVR procedures. The method in this study includes 4 major steps. First, the patient's cardiac CTA image was resampled to reduce the computation time. Next, the cardiac CTA image was segmented using an atlas-based approach. The most similar atlas was selected from a total of 8 atlases based on its image similarity to the input CTA image. Third, the aortic root segmentation from the previous step was transferred to the patient's whole-body CTA image by affine registration and refined in the fourth step using a deformable subdivision surface model fitting procedure based on image intensity. The pipeline was applied to 20 patients. The ground truth was created by an analyst who semi-automatically corrected the contours of the automatic method, where necessary. The average Dice similarity index between the segmentations of the automatic method and the ground truth was found to be 0.965±0.024. In conclusion, the current results are very promising.

  10. Compilation of the nuclear codes available in CTA

    International Nuclear Information System (INIS)

    D'Oliveira, A.B.; Moura Neto, C. de; Amorim, E.S. do; Ferreira, W.J.

    1979-07-01

    The present work is a compilation of some nuclear codes available in the Divisao de Estudos Avancados of the Instituto de Atividades Espaciais, (EAV/IAE/CTA). The codes are organized as the classification given by the Argonne National Laboratory. In each code are given: author, institution of origin, abstract, programming language and existent bibliography. (Author) [pt

  11. Strategy implementation for the CTA Atmospheric monitoring program

    Directory of Open Access Journals (Sweden)

    Doro Michele

    2015-01-01

    Full Text Available The Cherenkov Telescope Array (CTA is the next generation facility of Imaging Atmospheric Cherenkov Telescopes. It reaches unprecedented sensitivity and energy resolution in very-high-energy gamma-ray astronomy. CTA detects Cherenkov light emitted within an atmospheric shower of particles initiated by cosmic-gamma rays or cosmic rays entering the Earth's atmosphere. From the combination of images the Cherenkov light produces in the telescopes, one is able to infer the primary particle energy and direction. A correct energy estimation can be thus performed only if the local atmosphere is well characterized. The atmosphere not only affects the shower development itself, but also the Cherenkov photon transmission from the emission point in the particle shower, at about 10–20 km above the ground, to the detector. Cherenkov light on the ground is peaked in the UV-blue region, and therefore molecular and aerosol extinction phenomena are important. The goal of CTA is to control systematics in energy reconstruction to better than 10%. For this reason, a careful and continuous monitoring and characterization of the atmosphere is required. In addition, CTA will be operated as an observatory, with data made public along with appropriate analysis tools. High-level data quality can only be ensured if the atmospheric properties are consistently and continuously taken into account. In this contribution, we concentrate on discussing the implementation strategy for the various atmospheric monitoring instruments currently under discussion in CTA. These includes Raman lidars and ceilometers, stellar photometers and others available both from commercial providers and public research centers.

  12. Self-masking subtraction tomosynthesis

    International Nuclear Information System (INIS)

    Chakraborty, D.P.; Yester, M.V.; Barnes, G.T.; Lakshminarayanan, A.V.

    1984-01-01

    The authors tested the image quality and dose savings of self-masking subtraction tomosynthesis (SST), which combines digital tomosynthesis with subtraction of a blurred self-mask. High-quality images of the inner ear of a head phantom were obtained at moderate dose savings. Although they were taken with linear motion, they did not exhibit the streaking due to off-fulcrum objects that is characteristic of conventional linear tomography. SST could reduce patient dose by a factor of at least 12 in examinations of the inner ear, and the mechanical aspects can be implemented with moderate modifications of existing instrumentation

  13. Differential diagnosis between aneurysm and infundibular dilatation in the IC-PC region with 3D-CTA

    International Nuclear Information System (INIS)

    Kubota, Tsukasa; Niwa, Jun; Tanigawara, Tetsuya; Chiba, Masahiko; Akiyama, Yukinori; Inamura Shigeru

    2000-01-01

    In cases of asymptomatic internal carotid-posterior communicating artery (IC-PC) protrusions, it is sometimes difficult to differentiate infundibular dilatation (ID) from aneurysm by digital subtraction angiography. We applied three-dimensional CT angiography (3D-CTA) in 32 cases of these IC-PC protrusions. SOMATOM PLUS 4 was used under such conditions as to provide images with high spatial resolution. The shaded surface display (SSD) method was adopted to reconstruct the 3D images because of its advantage in separating overlapped vasculature. We also made reference to source images and maximum intensity projection (MIP) to make sure of our diagnoses. In all cases including 4 aneurysms and 28 IDs, we were able to distinguish between ID and aneurysm. The accuracy of 3D-CTA was confirmed by 9 surgical cases. Our technique was as follows: To inject a high dose of diluted contrast medium rapidly to smaller arteries for opacification of contrast medium. To exclude neighboring useless structures except for the very close structures such as posterior clinoid process from the target image focusing on the IC-PC region. To observe the reconstructed image of MIP and SSD from various angles. The contralateral and craniocaudal view were valuable. To change the threshold level gradually and observe the configurational changes of the apex of protrusion. Poorly developed PcomA was mostly delineated at the optimum threshold level. Otherwise, the apex of protrusion remained spherical in an aneurysm and became pyramidal in shape in an ID when the threshold level was gradually decreased. In conclusion, 3D-CTA was a useful modality for IC-PC protrusions to distinguish between ID and aneurysm. (author)

  14. Color Addition and Subtraction Apps

    Science.gov (United States)

    Ruiz, Frances; Ruiz, Michael J.

    2015-01-01

    Color addition and subtraction apps in HTML5 have been developed for students as an online hands-on experience so that they can more easily master principles introduced through traditional classroom demonstrations. The evolution of the additive RGB color model is traced through the early IBM color adapters so that students can proceed step by step…

  15. Digital subtraction angiography in traumatology

    International Nuclear Information System (INIS)

    Steudel, A.; Harder, T.; Lackner, K.; Schneider, B.; Orellano, L.; Bonn Univ.; Bonn Univ.

    1986-01-01

    The methods, indications and results of digital subtraction angiography in traumatology are presented, based on 56 examinations. The different use of intravenous or intraarterial DSA will be discussed with respect to expanding and localisation of traumatic vascular injury. DSA is recommended as the method of choice for follow-up after vascular reconstructive procedure. (orig.) [de

  16. Locality-Aware CTA Clustering For Modern GPUs

    Energy Technology Data Exchange (ETDEWEB)

    Li, Ang; Song, Shuaiwen; Liu, Weifeng; Liu, Xu; Kumar, Akash; Corporaal, Henk

    2017-04-08

    In this paper, we proposed a novel clustering technique for tapping into the performance potential of a largely ignored type of locality: inter-CTA locality. We first demonstrated the capability of the existing GPU hardware to exploit such locality, both spatially and temporally, on L1 or L1/Tex unified cache. To verify the potential of this locality, we quantified its existence in a broad spectrum of applications and discussed its sources of origin. Based on these insights, we proposed the concept of CTA-Clustering and its associated software techniques. Finally, We evaluated these techniques on all modern generations of NVIDIA GPU architectures. The experimental results showed that our proposed clustering techniques could significantly improve on-chip cache performance.

  17. Subtracted versus non-subtracted digital imaging in peripheral angiography

    International Nuclear Information System (INIS)

    Fink, U.; Heywang, S.; Mayr, B.; Berger, H.

    1989-01-01

    Digital subtraction angiography (DSA) plays an important role in the management of vascular diseases of the lower extremities. A disadvantage is the lack of an automatically moving table top. We used a 1,024x1,024 matrix with a large-screen intensifier system and an automated 'stepping' facility. In 161 examinations of the arteries of the lower extremity digital peripheral arteriography was performed with and without the subtraction technique. We compared the influence of different iodine concentrations in DA and DSA. Peripheral DA proved to be equal to peripheral DSA in the region of the pelvis, thigh and knee, with no adequate contrasting being obtained merely in the region of the lower leg arteries in about 45%. It is necessary to use contrast medium at a concentration of 300 mg I/ml. The installation of an automated 'stepping' facility reduces the amount of contrast' medium needed and the exposure time. (orig.)

  18. Role of CTA1R7K-COL-DD as a novel therapeutic mucosal tolerance-inducing vector for treatment of collagen-induced arthritis.

    Science.gov (United States)

    Hasselberg, Annemarie; Schön, Karin; Tarkowski, Andrej; Lycke, Nils

    2009-06-01

    To determine whether a cholera toxin-derived, novel immunomodulating fusion protein, CTA1R7K-COL-DD, carrying the class II major histocompatibility complex H-2q-restricted type II collagen peptide aa 259-274, can induce therapeutic tolerance and prevent collagen-induced arthritis (CIA) when administered intranasally in DBA/1 mice, and to assess whether ADP-ribosylation at the mucosal membranes exerts a regulatory function such that the outcome of tolerance or immune enhancement can be controlled. DBA/1 mice with CIA were treated intranasally with CTA1R7K-COL-DD. The therapeutic effect was monitored for 46 days after the onset of disease. Clinical scoring of disease, histologic examination of inflammation, and bone erosion were assessed, and cytokine levels were determined in the serum or supernatants from splenocytes stimulated with recall antigen. The protective effect of CTA1R7K-COL-DD resulted in roughly 60% of the mice having no clinical signs or histologic evidence of disease after treatment, and those with CIA had significantly milder disease with less bone erosion. The protective status was associated with lower serum titers of IgG1, IgG2a, IgG2b, and IgG3 anticollagen and a substantial decrease in the production of interleukin-6 (IL-6), IL-17, and interferon-gamma, while levels of IL-10 were markedly up-regulated both in the serum and at the T cell level. The enzymatically inactive mutant fusion protein CTA1R7K-COL-DD provided substantial therapeutic protection against CIA following intranasal administration. The mechanism behind the effect appears to be mediated by peptide-specific regulatory T cells induced by mucosal exposure to the peptide containing CTA1R7K-COL-DD vector. In addition, ADP-ribosylation at the mucosal membranes acts as a key regulator controlling mucosal tolerance or immunity.

  19. Dynamic gadolinium-enhanced subtraction MR imaging - a simple technique for the early diagnosis of Legg-Calve-Perthes disease: preliminary results

    International Nuclear Information System (INIS)

    Sebag, G.; Ducou Le Pointe, H.; Klein, I.; Maiza, D.; Mazda, K.; Bensahel, H.; Hassan, M.

    1997-01-01

    To determine whether the simple technique of dynamic gadolinium-enhanced subtraction MR imaging, which is available on standard MR units, can detect ischemia of the femoral head in children with early Legg-Calve-Perthes disease (LCP). Bone perfusion of eight hips in four patients (mean age 7.5 years) was studied using dynamic gadolinium-enhanced substraction MR imaging at the onset of proven LCP (with initial negative plain films). Enhancement of subtracted images was compared with that on standard MR images and with bone scintigraphy findings. Subtraction MR imaging depicted ischemia as a widespread absence of enhancement and was in good agreement with bone scintigraphy. The subtraction technique improved the sensitivity and the specificity of MR imaging in two children. Furthermore, subtraction MR imaging allowed recognition of the pattern of early reperfusion. Our preliminary results indicate that dynamic gadolinium-enhanced subtraction MRI is a simple and promising means of early recognition of ischemia in LCP. (orig.)

  20. Thallium-201 and technetium-99m pertechnetate subtraction scintigraphy in patients with hyperparathyroidism

    International Nuclear Information System (INIS)

    Kuwashima, Shigeko; Koizumi, Mitsuru; Goto, Masafumi; Nomura, Toshiharu; Fujioka, Mutsuhisa; Watari, Tsutomu

    1992-01-01

    A reliable technique for detecting and localizing abnormal parathyroid tissue has been a persistent problem. We evaluated thallium-technetium (Tl/Tc) subtraction scintigraphy in 16 patients with clinical biochemical evidence of hyperparathyroidism prior to other diagnostic methods and surgery. Seven patients had surgery and were confirmed to have parathyroid adenoma or hyperplasia. The other methods included ultrasonography (US) in 6 patients, computed tomography (CT) in 10 patients, magnetic resonance imaging (MRI) in 8 patients, and bone scintigraphy in 7 patients. In patients who had several imaging modalities, the detection rate was significantly better for Tl/Tc subtraction scan than for US, CT or MRI. Bote scintigraphy, though not so sensitive as Tl/Tc subtraction studies, was an important tool for evaluating metabolic bone disorder including hyperparathyroidism and renal osteodystrophy. Thus, Tl/Tc subtraction scan is more useful for diagnosis when hyperparathyroidism is suspected if both Tl/Tc subtraction scan and bone scan are performed. The detectability depended on the mass size, and detection of abnormal glands was greater for adenoma than for hyperplasia. The results suggest that Tl/Tc subtraction scan is a simple, non-invasive and useful tool for locating parathyroid abnormality even when compared with MRI. (author)

  1. Multi-slice CT for visualization of acute pulmonary embolism: single breath-hold subtraction technique

    International Nuclear Information System (INIS)

    Wildberger, J.E.; Mahnken, A.H.; Spuentrup, E.; Guenther, R.W.; Klotz, E.; Ditt, H.

    2005-01-01

    Purpose: the purpose of our preliminary animal study was to evaluate the feasibility of a new subtraction technique for visualization of perfusion defects within the lung parenchyma in segmental and subsegmental pulmonary embolism (PE). Materials and methods: in three healthy pigs, PE were artificially induced by fresh human clot material. Within a single breath-hold, CT angiography (CTA) was performed on a 16-slice multi-slice CT scanner (SOMATOM Sensation 16; Siemens, Forchheim, Germany) before and after intravenous application of 80 mL of contrast-medium, followed by a saline chaser. Scan parameters were 120 kV and 100 mAs eff. , using a collimation of 16 x 1.5 mm and a table speed/rot. of 36 mm (pitch: 1.5; rotation time: 0.5 s). A new 3D subtraction technique was developed, which is based on automated segmentation, non-linear spatial filtering and non-rigid registration. Data were analysed using a color-encoded ''compound view'' of parenchymal enhancement and CTA information displayed in axial, coronal and sagittal orientation. Results: subtraction was technically feasible in all three data sets. The mean scan time for each series was 4.7 s, interscan delay was 14.7 s, respectively. Therefore, an average breath-hold of approximately 24 s was required for the overall scanning procedure. Downstream of occluded segmental and subsegmental arteries, perfusion defects were clearly assessable, showing lower or missing enhancement compared to normally perfused lung parenchyma. In all pigs, additional peripheral areas with triangular shaped perfusion defects were delineated, considered typical for PE. Conclusions: our initial results from the animal model studied slow that perfusion imaging of PE is feasible within a single breath-hold. It allows a comprehensive assessment of perfusion deficits as the direct proof of a pulmonary embolus, can be combined with an indirect visual quantification of the density changes in the adjacent lung tissue. (orig.)

  2. Assessment of the feasible CTA windows for efficient spacing with energy-neutral CDO

    OpenAIRE

    Dalmau Codina, Ramon; Prats Menéndez, Xavier

    2016-01-01

    Continuous descent operations (CDO) with con- trolled times of arrival (CTA) at one or several metering fixes could enable environmentally friendly procedures at the same time that terminal airspace capacity is not compromised. This paper focuses on CTA updates once the descent has been already initiated, assessing the feasible CTA window (and associated fuel consumption) of CDO requiring neither thrust nor speed-brake usage alon...

  3. CTA-enhanced perfusion CT: an original method to perform ultra-low-dose CTA-enhanced perfusion CT

    Energy Technology Data Exchange (ETDEWEB)

    Tong, Elizabeth; Wintermark, Max [University of Virginia, Department of Radiology, Neuroradiology Division, Charlottesville, VA (United States)

    2014-11-15

    Utilizing CT angiography enhances image quality in PCT, thereby permitting acquisition at ultra-low dose. Dynamic CT acquisitions were obtained at 80 kVp with decreasing tube current-time product [milliamperes x seconds (mAs)] in patients suspected of ischemic stroke, with concurrent CTA of the cervical and intracranial arteries. By utilizing fast Fourier transformation, high spatial frequencies of CTA were combined with low spatial frequencies of PCT to create a virtual PCT dataset. The real and virtual PCT datasets with decreasing mAs were compared by assessing contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and noise and PCT values and by visual inspection of PCT parametric maps. Virtual PCT attained CNR and SNR three- to sevenfold superior to real PCT and noise reduction by a factor of 4-6 (p < 0.05). At 20 mAs, virtual PCT achieved diagnostic parametric maps, while the quality of real PCT maps was inadequate. At 10 mAs, both real and virtual PCT maps were nondiagnostic. Virtual PCT (but not real PCT) maps regained diagnostic quality at 10 mAs by applying 40 % adaptive statistical iterative reconstruction (ASIR) and improved further with 80 % ASIR. Our new method of creating virtual PCT by combining ultra-low-dose PCT with CTA information yields diagnostic perfusion parametric maps from PCT acquired at 20 or 10 mAs with 80 % ASIR. Effective dose is approximately 0.20 mSv, equivalent to two chest radiographs. (orig.)

  4. Exercise intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Yiannikas, J.

    1986-01-01

    Attempts to use exercise ventriculography have been made, not only to give diagnostic and perhaps even prognostic information in patients with coronary artery disease, but also in patients with valvular heart disease both before and after surgical intervention. Clearly an accurate method of assessing ventricular function under conditions of stress in various cardiac diseases would provide important information that would help in patient management. Exercise ventriculography using gated blood pool equilibrium technetium studies are widely used, but are limited by spatial resolution and by the foreshortening affects of visualizing the left ventricular chamber in the left anterior oblique view. First pass radionuclide studies have the added advantage of being able to visualize the ventricular chamber in the anterior or even the right anterior oblique view, but are even more limited by their spatial resolution problems. Several investigations have shown that digital subtraction angiography produces left ventricular images with a spatial resolution almost identical to that of conventional contrast ventriculography, but without the inherent problems of cardiac arrhythmias, which often limit the assessment of left ventricular function. Because of its ability to accurately delineate wall motion abnormalities, the technique may provide an adequate assessment of global and regional left ventricular function after exercise. Digital subtraction angiography may identify ischemic wall motion abnormalities produced by exercise in patients who already had significant permanent left ventricular damage from myocardial infarction

  5. CT Angiography of Peripheral Arterial Disease by 256-Slice Scanner: Accuracy, Advantages and Disadvantages Compared to Digital Subtraction Angiography.

    Science.gov (United States)

    Mishra, Atul; Jain, Narendra; Bhagwat, Anand

    2017-07-01

    Peripheral arterial occlusive disease (PAOD) may cause disabling claudication or critical limb ischemia. Multidetector computed tomography (CT) technology has evolved to the level of 256-slice CT scanners which has significantly improved the spatial and temporal resolution of the images. This has provided the capability of chasing the contrast bolus at a fast speed enabling angiographic imaging of long segments of the body. These images can be reconstructed in various planes and various modes for detailed analysis of the peripheral vascular diseases which helps in making treatment decision. The aim of this retrospective study was to compare the CT angiograms (CTAs) of all cases of PAOD done by 256-slice CT scanner at a tertiary care vascular center and comparing these images with the digital subtraction angiograms (DSAs) of these patients. The retrospective study included 53 patients who underwent both CTA and DSA at our center over a period of 3 years from March 2013 to March 2016. The CTA showed high sensitivity (93%) and specificity (92.7%) for overall assessment of degree of stenosis in a vascular segment in cases of aortic and lower limb occlusive disease. The assessment of lesions of infrapopliteal segment was comparatively inferior (sensitivity 91.6%, accuracy 73.3%, and positive predictive value 78.5%), more so in the presence of significant calcification. The advantages of CTA were its noninvasive nature, ability to image large area of body, almost no adverse effects to the patients, and better assessment of vessel wall disease. However, the CTA assessment of collaterals was inferior with a sensitivity of only 62.7% as compared to DSA. Overall, 256-slice CTA provides fast and accurate imaging of vascular tree which can restrict DSA only in few selected cases as a problem-solving tool where clinico-radiological mismatch is present.

  6. 99mTc-RBC subtraction scintigraphy

    International Nuclear Information System (INIS)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Kuranishi, Makoto; Sugishita, Kouki; Nakamura, Mamoru

    1994-01-01

    Sequential abdominal scintigrams with 99m Tc-labelled red blood cells (RBC) were subtracted for observing a site of gastrointestinal bleeding and calculating the bleeding rate. This method is technically very easy and can detect the site of bleeding with the minimum rate, as low as 0.2 ml/min., in a phantom experiment. In 23 cases with final diagnosis of gastrointestinal bleeding, conventional non-subtraction scintigraphy detected only 30% (7/23), but subtraction scintigraphy detected 61% (14/23). It was concluded that subtraction scintigraphy had higher sensitivity than conventional scintigraphy for early diagnosing bleeding. A combination of non-subtraction and subtraction scintigraphy is recommended to detect a site of gastrointestinal bleeding in a clinical setting. (author)

  7. Digital subtraction angiography in head and neck radiology

    International Nuclear Information System (INIS)

    Carmody, R.F.; Seeger, J.F.; Smith, R.L.; Horsley, W.W.; Miller, R.W.

    1984-01-01

    Intravenous digital subtraction angiography (IVDSA) was used to evaluate 44 patients with suspected otolaryngologic abnormalities. Sixteen had IVDSA for pulsatile tinnitus or suspected glomus tumor of the petrous bone. Nine patients were evaluated because of pulsatile neck masses, and 12 others had suspected tumors of the neck, face, and paranasal sinuses. Seven had IVDSA following head and neck trauma. The technique of examination is described. The current indications of IVDSA in head and neck radiology are discussed. It is concluded that IVDSA is a suitable substitute for conventional angiography for many otolaryngologic conditions and, because of its safety, can be used more liberally. (orig.)

  8. Digital subtraction angiography in head and neck radiology

    Energy Technology Data Exchange (ETDEWEB)

    Carmody, R F; Seeger, J F; Smith, R L; Horsley, W W; Miller, R W

    1984-07-01

    Intravenous digital subtraction angiography (IVDSA) was used to evaluate 44 patients with suspected otolaryngologic abnormalities. Sixteen had IVDSA for pulsatile tinnitus or suspected glomus tumor of the petrous bone. Nine patients were evaluated because of pulsatile neck masses, and 12 others had suspected tumors of the neck, face, and paranasal sinuses. Seven had IVDSA following head and neck trauma. The technique of examination is described. The current indications of IVDSA in head and neck radiology are discussed. It is concluded that IVDSA is a suitable substitute for conventional angiography for many otolaryngologic conditions and, because of its safety, can be used more liberally.

  9. BPHZL-subtraction scheme and axial gauges

    Energy Technology Data Exchange (ETDEWEB)

    Kreuzer, M.; Rebhan, A.; Schweda, M.; Piguet, O.

    1986-03-27

    The application of the BPHZL subtraction scheme to Yang-Mills theories in axial gauges is presented. In the auxillary mass formulation we show the validity of the convergence theorems for subtracted momentum space integrals, and we give the integral formulae necessary for one-loop calculations. (orig.).

  10. Development of digital subtraction system DAR-1200

    International Nuclear Information System (INIS)

    Kawai, Masumi; Shimizu, Yasumitsu; Ozaki, Takeshi; Sawada, Hiroshi; Uzuyama, Kazuhiro; Nishioka, Hiroyuki

    1989-01-01

    Digital subtraction angiography (DSA) has been of widespread use clinically, and it has attracted considerable attention in angiographic examination today. The merits of Shimadzu high resolution digital subtraction system DAR-1200 are reported in this paper. Furthermore, the principle and clinical usefullness of a new method of DSA called the Peak-Hold DSA are explained especially in details. (author)

  11. Digital subtraction angiography of the heart and lungs

    International Nuclear Information System (INIS)

    Moodie, D.S.; Yiannikas, J.

    1986-01-01

    This book contains 12 chapters. Some of the chapter titles are: Physical Principles of Cardiac Digital Subtraction Angiography, The Use of Intravenous Digital Subtraction Angiography in Evaluating Patients with Complex Congenital Heart Disease, Exercise Intravenous Digital Subtraction Angiograpny, Cardiomyopathic and Cardiac Neoplastic Disease, Digital Subtraction Angiography in the Catheterization Laboratory, and Cardiac Digital Subtraction Angiography - Future Directions

  12. Subtraction radiography and computer assisted densitometric analyses of standardized radiographs. A comparison study with /sup 125/I absorptiometry

    Energy Technology Data Exchange (ETDEWEB)

    Ortmann, L.F.; Dunford, R.; McHenry, K.; Hausmann, E.

    1985-01-01

    A standardized radiographic series of incrementally increasing alveolar crestal defects in skulls were subjected to analyses by subtraction radiography and computer assisted quantitative densitometric analysis. Subjects were able to detect change using subtraction radiography in alveolar bone defects with bone loss in the range of 1-5 percent as measured by /sup 125/I absorptiometry. Quantitative densitometric analyses utilizing radiographic pairs adjusted for differences in contrast (gamma corrected) can be used to follow longitudinal changes at a particular alveolar bone site. Such measurements correlate with change observed by /sup 125/I absorptiometry (r=0.82-0.94). (author).

  13. 3D/3D registration of coronary CTA and biplane XA reconstructions for improved image guidance

    Energy Technology Data Exchange (ETDEWEB)

    Dibildox, Gerardo, E-mail: g.dibildox@erasmusmc.nl; Baka, Nora; Walsum, Theo van [Biomedical Imaging Group Rotterdam, Departments of Radiology and Medical Informatics, Erasmus Medical Center, 3015 GE Rotterdam (Netherlands); Punt, Mark; Aben, Jean-Paul [Pie Medical Imaging, 6227 AJ Maastricht (Netherlands); Schultz, Carl [Department of Cardiology, Erasmus Medical Center, 3015 GE Rotterdam (Netherlands); Niessen, Wiro [Quantitative Imaging Group, Faculty of Applied Sciences, Delft University of Technology, 2628 CJ Delft, The Netherlands and Biomedical Imaging Group Rotterdam, Departments of Radiology and Medical Informatics, Erasmus Medical Center, 3015 GE Rotterdam (Netherlands)

    2014-09-15

    Purpose: The authors aim to improve image guidance during percutaneous coronary interventions of chronic total occlusions (CTO) by providing information obtained from computed tomography angiography (CTA) to the cardiac interventionist. To this end, the authors investigate a method to register a 3D CTA model to biplane reconstructions. Methods: The authors developed a method for registering preoperative coronary CTA with intraoperative biplane x-ray angiography (XA) images via 3D models of the coronary arteries. The models are extracted from the CTA and biplane XA images, and are temporally aligned based on CTA reconstruction phase and XA ECG signals. Rigid spatial alignment is achieved with a robust probabilistic point set registration approach using Gaussian mixture models (GMMs). This approach is extended by including orientation in the Gaussian mixtures and by weighting bifurcation points. The method is evaluated on retrospectively acquired coronary CTA datasets of 23 CTO patients for which biplane XA images are available. Results: The Gaussian mixture model approach achieved a median registration accuracy of 1.7 mm. The extended GMM approach including orientation was not significantly different (P > 0.1) but did improve robustness with regards to the initialization of the 3D models. Conclusions: The authors demonstrated that the GMM approach can effectively be applied to register CTA to biplane XA images for the purpose of improving image guidance in percutaneous coronary interventions.

  14. Digital subtraction angiography for breast cancer

    International Nuclear Information System (INIS)

    Tsurumi, Kiyohiko; Okuyama, Nobuo

    1987-01-01

    We performed digital subtraction angiography (DSA) on 42 patients with breast diseases to investigate its efficiency. As a result we came to the following conclusions: 1. The sensitivity was well evaluated in intraarterial digital subtraction angiography (IA-DSA) of breast. 2. IA-DSA could diagnose difficult cases like cancer which had undergone augmentation mammoplasty, or like Paget's disease and others. 3. DSA was a safe examination method. 4. The sensitivity of IA-DSA of breast cancer is superior to intravenous digital subtraction angiography (IV-DSA). (author)

  15. Three dimensional CT angiography (3D-CTA) in ruptured aneurysm surgery on acute stage

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Endo, Yuji; Nakano, Masayuki

    1998-01-01

    We evaluated three-dimensional CT angiography (3D-CTA) for the treatment of acutely ruptured cerebral aneurysms. Sixty patients with subarachnoid hemorrhage from cerebral aneurysms were investigated both by 3D-CTA and conventional angiography and 26 patients were studied using 3D-CTA without conventional angiography. In the 60 cases, both 3D-CTA and the conventional angiography revealed 100% accuracy in diagnosing ruptured aneurysms, and 3D-CTA and the conventional angiography showed 96% and 92% accuracy for unruptured aneurysms respectively. 3D-CTA was equal or superior to the conventional angiography. Based on these data, since December, 1996, we have operated on 26 consecutive patients with ruptured aneurysms located in the anterior circulation of the circle of Willis, using 3D-CTA without conventional angiography. Thirty-one aneurysms, including 5 associated unruptured aneurysms, were visualized by 3D-CTA and verified at surgery. All aneurysms were clipped successfully. We think that it will be possible to operate on most ruptured aneurysms using only 3D-CTA without the conventional angiography except for the cases of the following situations: if a cerebral infarction is present, conventional angiography is required to evaluate for a stenotic or occlusive lesion of the intracranial arteries, cervical carotid, or vertebral arteries; in cases of giant or large aneurysms, the dynamic information provided by the conventional angiography is needed in case bypass surgery is necessary; and for aneurysms close to bony structures, such as an internal carotid-ophthalmic artery aneurysm, conventional angiography is necessary. (author)

  16. Carotid body size on CTA: Correlation with comorbidities

    International Nuclear Information System (INIS)

    Cramer, J.A.; Wiggins, R.H.; Fudim, M.; Engelman, Z.J.; Sobotka, P.A.; Shah, L.M.

    2014-01-01

    Aim: To test the hypothesis that computed tomographic angiography (CTA) can identify carotid body enlargement in patients with sympathetically mediated diseases. Materials and methods: A retrospective chart review of all patients obtaining CTAs of the cervical vasculature at University of Utah Health Sciences Center over a 6-month period was performed. Widest axial measurements of both carotid bodies were performed on a picture archiving and communication system (PACS). Statistical analysis was then performed to compare the mean carotid body size between control patients and patients with diabetes mellitus, hypertension, and congestive heart failure. Results: Measurements were performed on 288 patients, with 134 controls. Of the remaining 154, 72 patients had diabetes mellitus, 46 had congestive heart failure, and 130 had hypertension. The control patients had a mean carotid body diameter of 2.3 mm. There was a statistically significant (p < 0.01) 20–25% increase in mean diameter with diabetes mellitus (2.8 mm), hypertension (2.7 mm), and congestive heart failure (2.7 mm; p < 0.01). Conclusions: This study found a 20–25% larger mean carotid body size in patients with diabetes mellitus, hypertension, and congestive heart failure relative to controls. However, this small enlargement should not mimic other carotid body diseases, such as a paraganglionoma. Moreover, these findings further support the proposed functional relationship between the carotid body and sympathetically mediated disease states

  17. A subtraction scheme for computing QCD jet cross sections at NNLO: integrating the subtraction terms I

    Science.gov (United States)

    Somogyi, Gábor; Trócsányi, Zoltán

    2008-08-01

    In previous articles we outlined a subtraction scheme for regularizing doubly-real emission and real-virtual emission in next-to-next-to-leading order (NNLO) calculations of jet cross sections in electron-positron annihilation. In order to find the NNLO correction these subtraction terms have to be integrated over the factorized unresolved phase space and combined with the two-loop corrections. In this paper we perform the integration of all one-parton unresolved subtraction terms.

  18. Digital subtraction angiography in ischemic cerebrovascular accidents

    Energy Technology Data Exchange (ETDEWEB)

    Manelfe, C.; Bonafe, A.; Ducos de Lahitte, M.; Rascol, A.; Prere, J.; Guiraud, B.; Marc-Vergnes, J.P. (Hopital Purpan, 31 - Toulouse (France))

    1983-12-29

    Recent advances in computer and radiological technology have permitted reassessment of intravenous angiography in the evaluation of cerebrovascular disorders. Although digital subtraction angiography is a relatively new technique, it has rapidly gained a widespread acceptance. It has extended the use of angiography to outpatients and to people in whom conventional angiography is contraindicated. This reliable, safe, and relatively noninvasive technique offers the user two benefits: real-time subtraction and enhanced image quality. The system allows angiographic evaluation of the extracranial and intracranial vessels by means of intravenous injection of contrast material. Extracranial studies clearly demonstrate stenoses and occlusions of the major cervicocephalic arteries. Intracranial studies usually detect major cerebrovascular occlusions and provide insight into the collateral flow patterns. Intravenous digital subtraction angiography permits accurate assessment of cervicocephalic vessels after surgical repair. Although intravenous digital subtraction angiography obviates the need for conventional angiography in many cases, movements from the patients, or superimposition of vascular structures can substantially degrade the quality of the images. Digital subtraction angiography with intra-arterial injection of contrast medium will be contemplated in patients with poor intravenous digital subtraction angiography studies prior to surgery.

  19. Digital subtraction angiography in ischemic cerebrovascular accidents

    International Nuclear Information System (INIS)

    Manelfe, C.; Bonafe, A.; Ducos de Lahitte, M.; Rascol, A.; Prere, J.; Guiraud, B.; Marc-Vergnes, J.P.

    1983-01-01

    Recent advances in computer and radiological technology have permitted reassessment of intravenous angiography in the evaluation of cerebrovascular disorders. Although digital subtraction angiography is a relatively new technique, it has rapidly gained a widespread acceptance. It has extended the use of angiography to outpatients and to people in whom conventional angiography is contraindicated. This reliable, safe, and relatively noninvasive technique offers the user two benefits: real-time subtraction and enhanced image quality. The system allows angiographic evaluation of the extracranial and intracranial vessels by means of intravenous injection of contrast material. Extracranial studies clearly demonstrate stenoses and occlusions of the major cervicocephalic arteries. Intracranial studies usually detect major cerebrovascular occlusions and provide insight into the collateral flow patterns. Intravenous digital subtraction angiography permits accurate assessment of cervicocephalic vessels after surgical repair. Although intravenous digital subtraction angiography obviates the need for conventional angiography in many cases, movements from the patients, or superimposition of vascular structures can substantially degrade the quality of the images. Digital subtraction angiography with intra-arterial injection of contrast medium will be contemplated in patients with poor intravenous digital subtraction angiography studies prior to surgery [fr

  20. Dosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma rays

    CERN Document Server

    Peimel-Stuglik, Z

    2001-01-01

    The usefulness of two kinds of untinted CTA foils: Fuji CTR-125 dosimetric foil and technical CTA-T foil, produced by 'Zaklady Chemiczne, 'Gorzow Wielkopolski' as support for light-sensitive layers of amateur photo-films, for sup 6 sup 0 Co gamma ray dosimetry was investigated. In spite of rather bad physical parameters of the technical foil (spread of foil thickness, high and different initial absorbance) the dosimetric response of both foils for sup 6 sup 0 Co gamma rays was similar. The CTA-T foil can be used for routine dosimetry providing that dosimetric signals have to be calculated exactly as recommended by the ASTM (American Society for Testing and Materials) standard, i.e. as the difference of absorbance of irradiated and (the same) non-irradiated foil. Any other approach may lead to high errors of dose evaluation. The last is true also for other CTA foils, especially after long self-life.

  1. Dosimetric response of united, commercially available CTA foils for 60Co gamma rays

    International Nuclear Information System (INIS)

    Peimel-Stuglik, Z.

    2001-01-01

    The usefulness of two kinds of untinted CTA foils: Fuji CTR-125 dosimetric foil and technical CTA-T foil, produced by 'Zaklady Chemiczne, 'Gorzow Wielkopolski' as support for light-sensitive layers of amateur photo-films, for 60 Co gamma ray dosimetry was investigated. In spite of rather bad physical parameters of the technical foil (spread of foil thickness, high and different initial absorbance) the dosimetric response of both foils for 60 Co gamma rays was similar. The CTA-T foil can be used for routine dosimetry providing that dosimetric signals have to be calculated exactly as recommended by the ASTM (American Society for Testing and Materials) standard, i.e. as the difference of absorbance of irradiated and (the same) non-irradiated foil. Any other approach may lead to high errors of dose evaluation. The last is true also for other CTA foils, especially after long self-life. (author)

  2. The Constitution and Operation of the Constant Temperature Anemometer(CTA:IFA 300)

    Energy Technology Data Exchange (ETDEWEB)

    Nam, H. Y.; Kim, J. M.; Choi, B. H.; Choi, J. H.; Jeong, J. Y.; Kim, B. H.; Kim, T. J.; Cha, J. E.; Kim, H. R

    2005-09-15

    This study shows the constitution and application method on constant temperature anemometer(CTA-Model : IFA 300 by TSI Co.). Especially, the software instruction(Thermal Pro Ver. 4.55) was re-adjusted for users.

  3. Anatomy-based automatic detection and segmentation of major vessels in thoracic CTA images

    International Nuclear Information System (INIS)

    Zou Xiaotao; Liang Jianming; Wolf, M.; Salganicoff, M.; Krishnan, A.; Nadich, D.P.

    2007-01-01

    Existing approaches for automated computerized detection of pulmonary embolism (PE) using computed tomography angiography (CTA) usually focus on segmental and sub-segmental emboli. The goal of our current research is to extend our existing approach to automated detection of central PE. In order to detect central emboli, the major vessels must be first identified and segmented automatically. This submission presents an anatomy-based method for automatic computerized detection and segmentation of aortas and main pulmonary arteries in CTA images. (orig.)

  4. The High-Level Interface Definitions in the ASTRI/CTA Mini Array Software System (MASS)

    Science.gov (United States)

    Conforti, V.; Tosti, G.; Schwarz, J.; Bruno, P.; Cefal‘A, M.; Paola, A. D.; Gianotti, F.; Grillo, A.; Russo, F.; Tanci, C.; Testa, V.; Antonelli, L. A.; Canestrari, R.; Catalano, O.; Fiorini, M.; Gallozzi, S.; Giro, E.; Palombara, N. L.; Leto, G.; Maccarone, M. C.; Pareschi, G.; Stringhetti, L.; Trifoglio, M.; Vercellone, S.; Astri Collaboration; Cta Consortium

    2015-09-01

    ASTRI (Astrofisica con Specchi a Tecnologia Replicante Italiana) is a Flagship Project funded by the Italian Ministry of Education, University and Research, and led by INAF, the Italian National Institute of Astrophysics. Within this framework, INAF is currently developing an end-to-end prototype, named ASTRI SST-2M, of a Small Size Dual-Mirror Telescope for the Cherenkov Telescope Array, CTA. A second goal of the project is the realization of the ASTRI/CTA mini-array, which will be composed of seven SST-2M telescopes placed at the CTA Southern Site. The ASTRI Mini Array Software System (MASS) is designed to support the ASTRI/CTA mini-array operations. MASS is being built on top of the ALMA Common Software (ACS) framework, which provides support for the implementation of distributed data acquisition and control systems, and functionality for log and alarm management, message driven communication and hardware devices management. The first version of the MASS system, which will comply with the CTA requirements and guidelines, will be tested on the ASTRI SST-2M prototype. In this contribution we present the interface definitions of the MASS high level components in charge of the ASTRI SST-2M observation scheduling, telescope control and monitoring, and data taking. Particular emphasis is given to their potential reuse for the ASTRI/CTA mini-array.

  5. Predictive Value of CTA Spot Sign on Hematoma Expansion in Intracerebral Hemorrhage Patients

    Directory of Open Access Journals (Sweden)

    Wen-Jie Peng

    2017-01-01

    Full Text Available Hematoma expansion (HE occurs in approximately one-third of patients with intracerebral hemorrhage and leads to high rates of mortality and morbidity. Currently, contrast extravasation within hematoma, termed the spot sign on computed tomography angiography (CTA, has been identified as a strong independent predictor of early hematoma expansion. Past studies indicate that the spot sign is a dynamic entity and is indicative of active hemorrhage. Furthermore, to enhance the spot sign’s accuracy of predicting HE, spot parameters observed on CTA or dynamic CTA were used for its quantification. In addition, spot signs detected on multiphase CTA and dynamic CTA are shown to have higher sensitivity and specificity when compared with simple standardized spot sign detection in recent studies. Based on the spot sign, novel methods such as leakage sign and rate of contrast extravasation were explored to redefine HE prediction in combination with clinical characteristics and spot sign on CTA to assist clinical judgment. The spot sign is an accepted independent predictor of active hemorrhage and is used in both secondary intracerebral hemorrhage and the process of surgical assessment for hemorrhagic risk in patients with ischemic stroke. Spot sign predicts patients at high risk for hematoma expansion.

  6. X-ray image subtracting system

    International Nuclear Information System (INIS)

    Wesbey, W.H.; Keyes, G.S.; Georges, J.-P.J.

    1982-01-01

    An X-ray image subtracting system for making low contrast structures in the images more conspicuous is described. An X-ray source projects successive high and low energy X-ray beam pulses through a body and the resultant X-ray images are converted to optical images. Two image pick-up devices such as TV cameras that have synchronously operated shutters receive the alternate images and convert them to corresponding analog video signals. In some embodiments, the analog signals are converted to a matrix of digital pixel signals that are variously processed and subtracted and converted to signals for driving a TV monitor display and analog storage devices. In other embodiments the signals are processed and subtracted in analog form for display. The high and low energy pulses can follow each other immediately so good registration between subtracted images is obtainable even though the anatomy is in motion. The energy levels of the X-ray pulses are chosen to maximize the difference in attenuation between the anatomical structure which is to be subtracted out and that which remains. (author)

  7. Left-right subtraction of brain CT

    International Nuclear Information System (INIS)

    Ishiguchi, Tsuneo; Sakuma, Sadayuki

    1986-01-01

    A new image-processing method to obtain a left-right subtraction image of CT was designed for the automated detection of abnormalities in brain CT. An original CT image was divided in two by a centerline. Then the right half of the image was subtracted from the left half by calculating the absorption value of the pixels on the symmetrical positions against the centerline. The mean and the standard deviation of the absorption value of the pixels in the subtraction image were used as parameters for analysis, and the detectability of abnormal CT findings was evaluated in 100 cases - 50 cases each with normal and abnormal CT. The presence of abnormalities could be diagnosed with a sensitivity of 86 %, a specificity of 90 %, and an overall accuracy of 88 % when the borderline of these parameters between normal and abnormal CT was set at the mean + 2SD in the normal group. As a further analysis, the CT image was subdivided into several areas from a functional or anatomical viewpoint, such as cerebral vascular territories, and the left-right subtraction image of each area was obtained. The possibilities of diagnosing the location of an abnormality and of detecting smaller lesions with this method were shown. Left-right subtraction was considered to be a useful method for the detection of asymmetric abnormalities in the automated diagnosis of brain CT. (author)

  8. Detection of pulmonary nodules on lung X-ray images. Studies on multi-resolutional filter and energy subtraction images

    International Nuclear Information System (INIS)

    Sawada, Akira; Sato, Yoshinobu; Kido, Shoji; Tamura, Shinichi

    1999-01-01

    The purpose of this work is to prove the effectiveness of an energy subtraction image for the detection of pulmonary nodules and the effectiveness of multi-resolutional filter on an energy subtraction image to detect pulmonary nodules. Also we study influential factors to the accuracy of detection of pulmonary nodules from viewpoints of types of images, types of digital filters and types of evaluation methods. As one type of images, we select an energy subtraction image, which removes bones such as ribs from the conventional X-ray image by utilizing the difference of X-ray absorption ratios at different energy between bones and soft tissue. Ribs and vessels are major causes of CAD errors in detection of pulmonary nodules and many researches have tried to solve this problem. So we select conventional X-ray images and energy subtraction X-ray images as types of images, and at the same time select ∇ 2 G (Laplacian of Guassian) filter, Min-DD (Minimum Directional Difference) filter and our multi-resolutional filter as types of digital filters. Also we select two evaluation methods and prove the effectiveness of an energy subtraction image, the effectiveness of Min-DD filter on a conventional X-ray image and the effectiveness of multi-resolutional filter on an energy subtraction image. (author)

  9. Subtractive manufacturing of customized hydroxyapatite scaffolds for bone regeneration

    Czech Academy of Sciences Publication Activity Database

    Trunec, M.; Chlup, Zdeněk

    2017-01-01

    Roč. 43, č. 14 (2017), s. 11265-11273 ISSN 0272-8842 R&D Projects: GA MŠk(CZ) LQ1601 Institutional support: RVO:68081723 Keywords : tissue engineering applications * in-vivo * porous hydroxyapatite * phosphate bioceramics * suspensions * ceramics * laser * optimization * osteogenesis * deposition * Milling (A) * Porosity (B) * Apatite (D) * Biopmedical properties (E) * Scaffold Subject RIV: JH - Ceramics, Fire-Resistant Materials and Glass OBOR OECD: Ceramics Impact factor: 2.986, year: 2016

  10. CaMKII Requirement for in Vivo Insular Cortex LTP Maintenance and CTA Memory Persistence

    Directory of Open Access Journals (Sweden)

    Yectivani Juárez-Muñoz

    2017-11-01

    Full Text Available Calcium-calmodulin/dependent protein kinase II (CaMKII plays an essential role in LTP induction, but since it has the capacity to remain persistently activated even after the decay of external stimuli it has been proposed that it can also be necessary for LTP maintenance and therefore for memory persistence. It has been shown that basolateral amygdaloid nucleus (Bla stimulation induces long-term potentiation (LTP in the insular cortex (IC, a neocortical region implicated in the acquisition and retention of conditioned taste aversion (CTA. Our previous studies have demonstrated that induction of LTP in the Bla-IC pathway before CTA training increased the retention of this task. Although it is known that IC-LTP induction and CTA consolidation share similar molecular mechanisms, little is known about the molecular actors that underlie their maintenance. The purpose of the present study was to evaluate the role of CaMKII in the maintenance of in vivo Bla-IC LTP as well as in the persistence of CTA long-term memory (LTM. Our results show that acute microinfusion of myr-CaMKIINtide, a selective inhibitor of CaMKII, in the IC of adult rats during the late-phase of in vivo Bla-IC LTP blocked its maintenance. Moreover, the intracortical inhibition of CaMKII 24 h after CTA acquisition impairs CTA-LTM persistence. Together these results indicate that CaMKII is a central key component for the maintenance of neocortical synaptic plasticity as well as for persistence of CTA-LTM.

  11. [Development of a digital chest phantom for studies on energy subtraction techniques].

    Science.gov (United States)

    Hayashi, Norio; Taniguchi, Anna; Noto, Kimiya; Shimosegawa, Masayuki; Ogura, Toshihiro; Doi, Kunio

    2014-03-01

    Digital chest phantoms continue to play a significant role in optimizing imaging parameters for chest X-ray examinations. The purpose of this study was to develop a digital chest phantom for studies on energy subtraction techniques under ideal conditions without image noise. Computed tomography (CT) images from the LIDC (Lung Image Database Consortium) were employed to develop a digital chest phantom. The method consisted of the following four steps: 1) segmentation of the lung and bone regions on CT images; 2) creation of simulated nodules; 3) transformation to attenuation coefficient maps from the segmented images; and 4) projection from attenuation coefficient maps. To evaluate the usefulness of digital chest phantoms, we determined the contrast of the simulated nodules in projection images of the digital chest phantom using high and low X-ray energies, soft tissue images obtained by energy subtraction, and "gold standard" images of the soft tissues. Using our method, the lung and bone regions were segmented on the original CT images. The contrast of simulated nodules in soft tissue images obtained by energy subtraction closely matched that obtained using the gold standard images. We thus conclude that it is possible to carry out simulation studies based on energy subtraction techniques using the created digital chest phantoms. Our method is potentially useful for performing simulation studies for optimizing the imaging parameters in chest X-ray examinations.

  12. A simple digital subtraction angiographic instrument

    International Nuclear Information System (INIS)

    Ando, Hiroshi; Kobayashi, Tsuyoshi; Imai, Yutaka; Yanagishita, Akira

    1983-01-01

    A digital subtraction angiographic instrument was manufactured using a conventional x-ray TV for gastrointestinal series and a computer for processing of nuclear medical data. The results of visualization of the aorta and its primary branches were reviewed with demonstrable cases. (Chiba, N.)

  13. Digital subtraction angiography: myths and reality

    International Nuclear Information System (INIS)

    Levin, D.C.

    1984-01-01

    Some of the claims made about digital subtraction angiography (DSA) when it was first developed have turned out to be greatly exaggerated, and some members of the radiologic community have become disillusioned with its capabilities. The author discusses some of the limitations of DSA, and concludes that the advantages of DSA outweigh its limitations

  14. Digital subtraction angiography of carotid bifurcation

    International Nuclear Information System (INIS)

    Vries, A.R. de.

    1984-01-01

    This study demonstrates the reliability of digital subtraction angiography (DSA) by means of intra- and interobserver investigations as well as indicating the possibility of substituting catheterangiography by DSA in the diagnosis of carotid bifurcation. Whenever insufficient information is obtained from the combination of non-invasive investigation and DSA, a catheterangiogram will be necessary. (Auth.)

  15. Probabilistic Model-based Background Subtraction

    DEFF Research Database (Denmark)

    Krüger, Volker; Anderson, Jakob; Prehn, Thomas

    2005-01-01

    is the correlation between pixels. In this paper we introduce a model-based background subtraction approach which facilitates prior knowledge of pixel correlations for clearer and better results. Model knowledge is being learned from good training video data, the data is stored for fast access in a hierarchical...

  16. Development of Shimadzu digital subtraction system

    International Nuclear Information System (INIS)

    Nishioka, Hiroyuki; Shibata, Koichi; Shimizu, Yasumitsu; Shibata, Kenji; Wani, Hidenobu

    1985-01-01

    Shimadzu has recently developed a digital subtraction system. It can perform intra-arterial digital subtraction angiography (DSA) using low concentration of contrast medium, or can visualize arteries with intravenuous injection. It can extremely reduce patient's pain in angiography. Image quality of DSA has been much improved by the development of high quality image amplifiers, improvement of signal-to-noise ratio of the x-ray television unit and the development of digital disk recorders. The peak-hold subtraction method that is now under clinical study presents images of blood vessels as the trace of the flow of contrast medium. The maximum-hold memory where the maximum value of the brightness in some period is stored for every picture element is subtracted from the minimum-hold memory where the minimum value is stored, and thus images of blood vessels can be obtained. Hardware of this method is rather simple and it is expected that the amount of contrast medium may be reduced or x-ray dose of the patient may be decreased. (author)

  17. Digital subtraction angiography: first 900 cases

    International Nuclear Information System (INIS)

    Rodgers, H.

    1984-01-01

    The diagnostic technique of digital subtraction angiography (DSA) is briefly outlined. The operational and technical experiences with a DR-960 DSA system used in the examination of the first 900 cases at St. Thomas' Hospital, London are described. (U.K.)

  18. Radionuclide identification using subtractive clustering method

    International Nuclear Information System (INIS)

    Farias, Marcos Santana; Mourelle, Luiza de Macedo

    2011-01-01

    Radionuclide identification is crucial to planning protective measures in emergency situations. This paper presents the application of a method for a classification system of radioactive elements with a fast and efficient response. To achieve this goal is proposed the application of subtractive clustering algorithm. The proposed application can be implemented in reconfigurable hardware, a flexible medium to implement digital hardware circuits. (author)

  19. DIRAC framework evaluation for the Fermi-LAT and CTA experiments

    International Nuclear Information System (INIS)

    Arrabito, L; Cohen-Tanugi, J; Piron, F; Renaud, M; Rolland, V; Diaz, R Graciani; Longo, F; Kuss, M; Sapunov, M; Tsaregorodtsev, A; Zimmer, S

    2014-01-01

    DIRAC (Distributed Infrastructure with Remote Agent Control) is a general framework for the management of tasks over distributed heterogeneous computing environments. It has been originally developed to support the production activities of the LHCb (Large Hadron Collider Beauty) experiment and today is extensively used by several particle physics and biology communities. Current (Fermi Large Area Telescope – LAT) and planned (Cherenkov Telescope Array – CTA) new generation astrophysical/cosmological experiments, with very large processing and storage needs, are currently investigating the usability of DIRAC in this context. Each of these use cases has some peculiarities: Fermi-LAT will interface DIRAC to its own workflow system to allow the access to the grid resources, while CTA is using DIRAC as workflow management system for Monte Carlo production and analysis on the grid. We describe the prototype effort that we lead toward deploying a DIRAC solution for some aspects of Fermi-LAT and CTA needs.

  20. Removal of bone in CT angiography of the cervical arteries by piecewise matched mask bone elimination

    International Nuclear Information System (INIS)

    Straten, Marcel van; Venema, Henk W.; Streekstra, Geert J.; Majoie, Charles B.L.M.; Heeten, Gerard J. den; Grimbergen, Cornelis A.

    2004-01-01

    In maximum intensity projection (MIP) images of CT angiography (CTA) scans, the arteries are often obscured by bone. A bone removal method is presented that uses an additional, nonenhanced scan to create a mask of the bone by thresholding and dilation. After registration of the CTA scan and the additional scan, the bone in the CTA scan is masked. As the cervical area contains bones that can move with respect to each other, these bones are separated first using a watershed algorithm, and then registered individually. A phantom study was performed to evaluate and quantify the tradeoff between the removal of the bone and the preservation of the arteries contiguous to the bone. The influence of algorithm parameters and scan parameters was studied. The method was clinically evaluated with data sets of 35 patients. Best results were obtained with a threshold of 150 HU and a dilation of 8 in-plane voxels and two out-of-plane voxels. The mean width of the soft tissue layer, which is also masked, was approximately 1 mm. The mAs value of the nonenhanced scan could be reduced from 250 mAs to 65 mAs without a loss of quality. In 32 cases the bones were registered correctly and removed completely. In three cases the bone separation was not completely successful, and consequently the bone was not completely removed. The piecewise matched mask bone elimination method proved to be able to obtain MIP images of the cervical arteries free from overprojecting bone in a fully automatic way and with only a slight increase of radiation dose

  1. Late protein synthesis-dependent phases in CTA long-term memory: BDNF requirement

    Directory of Open Access Journals (Sweden)

    Araceli eMartínez-Moreno

    2011-09-01

    Full Text Available It has been proposed that long-term memory persistence requires a late protein synthesis-dependent phase, even many hours after memory acquisition. Brain-derived neurotrophic factor (BDNF is an essential protein synthesis product that has emerged as one of the most potent molecular mediators for long-term synaptic plasticity. Studies in the rat hippocampus have been shown that BDNF is capable to rescue the late-phase of long-term potentiation as well as the hippocampus-related long-term memory when protein synthesis was inhibited. Our previous studies on the insular cortex (IC, a region of the temporal cortex implicated in the acquisition and storage of conditioned taste aversion (CTA, have demonstrated that intracortical delivery of BDNF reverses the deficit in CTA memory caused by the inhibition of IC protein synthesis due to anisomycin administration during early acquisition. In this work, we first analyze whether CTA memory storage is protein synthesis dependent in different time-windows. We observed that CTA memory become sensible to protein synthesis inhibition 5 and 7 hours after acquisition. Then, we explore the effect of BDNF delivery (2 μg/2 μl per side in the IC during those late protein synthesis-dependent phases. Our results show that BDNF reverses the CTA memory deficit produced by protein synthesis inhibition in both phases. These findings support the notion that recurrent rounds of consolidation-like events take place in the neocortex for maintenance of CTA memory trace and that BDNF is an essential component of these processes.

  2. Late Protein Synthesis-Dependent Phases in CTA Long-Term Memory: BDNF Requirement.

    Science.gov (United States)

    Martínez-Moreno, Araceli; Rodríguez-Durán, Luis F; Escobar, Martha L

    2011-01-01

    It has been proposed that long-term memory (LTM) persistence requires a late protein synthesis-dependent phase, even many hours after memory acquisition. Brain-derived neurotrophic factor (BDNF) is an essential protein synthesis product that has emerged as one of the most potent molecular mediators for long-term synaptic plasticity. Studies in the rat hippocampus have been shown that BDNF is capable to rescue the late-phase of long-term potentiation as well as the hippocampus-related LTM when protein synthesis was inhibited. Our previous studies on the insular cortex (IC), a region of the temporal cortex implicated in the acquisition and storage of conditioned taste aversion (CTA), have demonstrated that intracortical delivery of BDNF reverses the deficit in CTA memory caused by the inhibition of IC protein synthesis due to anisomycin administration during early acquisition. In this work, we first analyze whether CTA memory storage is protein synthesis-dependent in different time windows. We observed that CTA memory become sensible to protein synthesis inhibition 5 and 7 h after acquisition. Then, we explore the effect of BDNF delivery (2 μg/2 μl per side) in the IC during those late protein synthesis-dependent phases. Our results show that BDNF reverses the CTA memory deficit produced by protein synthesis inhibition in both phases. These findings support the notion that recurrent rounds of consolidation-like events take place in the neocortex for maintenance of CTA memory trace and that BDNF is an essential component of these processes.

  3. Late Protein Synthesis-Dependent Phases in CTA Long-Term Memory: BDNF Requirement

    Science.gov (United States)

    Martínez-Moreno, Araceli; Rodríguez-Durán, Luis F.; Escobar, Martha L.

    2011-01-01

    It has been proposed that long-term memory (LTM) persistence requires a late protein synthesis-dependent phase, even many hours after memory acquisition. Brain-derived neurotrophic factor (BDNF) is an essential protein synthesis product that has emerged as one of the most potent molecular mediators for long-term synaptic plasticity. Studies in the rat hippocampus have been shown that BDNF is capable to rescue the late-phase of long-term potentiation as well as the hippocampus-related LTM when protein synthesis was inhibited. Our previous studies on the insular cortex (IC), a region of the temporal cortex implicated in the acquisition and storage of conditioned taste aversion (CTA), have demonstrated that intracortical delivery of BDNF reverses the deficit in CTA memory caused by the inhibition of IC protein synthesis due to anisomycin administration during early acquisition. In this work, we first analyze whether CTA memory storage is protein synthesis-dependent in different time windows. We observed that CTA memory become sensible to protein synthesis inhibition 5 and 7 h after acquisition. Then, we explore the effect of BDNF delivery (2 μg/2 μl per side) in the IC during those late protein synthesis-dependent phases. Our results show that BDNF reverses the CTA memory deficit produced by protein synthesis inhibition in both phases. These findings support the notion that recurrent rounds of consolidation-like events take place in the neocortex for maintenance of CTA memory trace and that BDNF is an essential component of these processes. PMID:21960964

  4. Phase measuring deflectometry. An improved setup for measuring CTA mirror facets

    Energy Technology Data Exchange (ETDEWEB)

    Specovius, Andreas; Eldik, Christopher van; Woernlein, Andre; Ziegler, Alexander [Erlangen Centre for Astroparticle Physics (ECAP) (Germany)

    2016-07-01

    The future Cherenkov Telescope Array (CTA) will consist of up to 100 single telescopes with a total reflecting surface of ∝10.000 m{sup 2} made of numerous mirror facets. Characterizing the surface properties of these facets is quite challenging concerning time and logistics. An efficient way to reliably reconstruct the surface of specular free-forms is Phase Measuring Deflectometry (PMD). PMD is routinely used to characterize the focal distance and point spread function of spherical CTA prototype mirrors. To address the possibility to measure the surface properties of aspherical mirrors, a new PMD setup has recently been built. First experience with this setup is reported.

  5. Comparison of CTA and Textual Feedback in Usability Testing for Malaysian Users

    DEFF Research Database (Denmark)

    Sivaji, Ashok; Clemmensen, Torkil; Nielsen, Søren Feodor

    Usability moderators found that the concurrent think-aloud (CTA) method has some cultural limitation that impacts usability testing with Malaysian users. This gives rise to proposing a new method called textual feedback. The research question is to determine whether there are any differences...... in usability defects from the concurrent think-aloud (CTA) method (Condition 2) and textual feedback method (Condition 1) within the same group of Malaysian users. A pair-wise t-test was used, whereby users were subjected to performing usability task using both methods. Results reveal that we can reject...

  6. Postoperative three-dimensional CT angiography after cerebral aneurysm clipping with titanium clips: detection with single detector CT. Comparison with intra-arterial digital subtraction angiography

    International Nuclear Information System (INIS)

    Sakuma, I.; Tomura, N.; Kinouchi, H.; Takahashi, S.; Otani, T.; Watarai, J.; Mizoi, K.

    2006-01-01

    AIM: To assess the significance of three-dimensional computed tomography angiography (3D-CTA) in detecting remnant necks after cerebral aneurysm clipping. MATERIALS AND METHODS: A total of 59 patients (77 aneurysms) underwent surgery using titanium clips. Two blinded observers independently evaluated the presence of neck remnants on shaded-surface display (SSD) imaging, volume rendered (VR) imaging, and intra-arterial digital subtraction angiography (IADSA). RESULTS: Mean sensitivity and specificity for detecting neck remnants were 50.0 and 74.2% for SSD imaging, 61.5 and 82.8% for VR imaging, and 92.3 and 92.2% for IADSA, respectively. Receiver operating characteristic (ROC) analysis revealed excellent diagnostic performance for IADSA [mean area under ROC curve (Az)=0.97], and good diagnostic performance for 3D-CTA (Az=0.70 and 0.76 for SSD and VR, respectively). Specificity of VR was better than that SSD (p=0.082), however, there was no significant difference between them. CONCLUSION: Use of 3D-CTA techniques can facilitate postoperative evaluation

  7. The use of 4D-CTA in the diagnostic work-up of brain arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Willems, Peter W.A. [Toronto Western Hospital, UHN, Division of Neuroradiology, Department of Medical Imaging, Toronto, Ontario (Canada); Leiden University Medical Center, Department of Radiology, Leiden (Netherlands); Taeshineetanakul, Patamintita; Terbrugge, Karel G.; Krings, Timo [Toronto Western Hospital, UHN, Division of Neuroradiology, Department of Medical Imaging, Toronto, Ontario (Canada); Schenk, Barry; Brouwer, Patrick A. [Leiden University Medical Center, Department of Radiology, Leiden (Netherlands)

    2012-02-15

    We aimed to evaluate the use of time-resolved whole-head CT angiography (4D-CTA) in patients with an untreated arteriovenous malformation of the brain (bAVM), as demonstrated by catheter angiography (DSA). Seventeen patients with a DSA-proven bAVM were enrolled. These were subjected to 4D-CTA imaging using a 320 detector row CT scanner. Using a standardized scoring sheet, all studies were analyzed by a panel of three readers. This panel was blind to the DSA results at the time of reading the 4D-CTA. 4D-CTA detected all bAVMs. With regard to the Spetzler-Martin grade, 4D-CTA disagreed with DSA in only one case, where deep venous drainage was missed. Further discrepancies between 4D-CTA and DSA analyses included underestimation of the nidus size in small lesions (four cases), misinterpretation of a feeding vessel (one case), misinterpretation of indirect feeding through pial collaterals (three cases) and oversight of mild arterial enlargement (two cases). 4D-CTA correctly distinguished low-flow from high-flow lesions and detected dural/transosseous feeding (one case), venous narrowing (one case) and venous pouches (nine cases). In this series, 4D-CTA was able to detect all bAVMs. Although some angioarchitectural details were missed or misinterpreted when compared to DSA, 4D-CTA evaluation was sufficiently accurate to diagnose the shunt and classify it. Moreover, 4D-CTA adds cross-sectional imaging and perfusion maps, helpful in treatment planning. 4D-CTA appears to be a valuable new adjunct in the non-invasive diagnostic work-up of bAVMs and their follow-up when managed conservatively. (orig.)

  8. The use of 4D-CTA in the diagnostic work-up of brain arteriovenous malformations

    International Nuclear Information System (INIS)

    Willems, Peter W.A.; Taeshineetanakul, Patamintita; Terbrugge, Karel G.; Krings, Timo; Schenk, Barry; Brouwer, Patrick A.

    2012-01-01

    We aimed to evaluate the use of time-resolved whole-head CT angiography (4D-CTA) in patients with an untreated arteriovenous malformation of the brain (bAVM), as demonstrated by catheter angiography (DSA). Seventeen patients with a DSA-proven bAVM were enrolled. These were subjected to 4D-CTA imaging using a 320 detector row CT scanner. Using a standardized scoring sheet, all studies were analyzed by a panel of three readers. This panel was blind to the DSA results at the time of reading the 4D-CTA. 4D-CTA detected all bAVMs. With regard to the Spetzler-Martin grade, 4D-CTA disagreed with DSA in only one case, where deep venous drainage was missed. Further discrepancies between 4D-CTA and DSA analyses included underestimation of the nidus size in small lesions (four cases), misinterpretation of a feeding vessel (one case), misinterpretation of indirect feeding through pial collaterals (three cases) and oversight of mild arterial enlargement (two cases). 4D-CTA correctly distinguished low-flow from high-flow lesions and detected dural/transosseous feeding (one case), venous narrowing (one case) and venous pouches (nine cases). In this series, 4D-CTA was able to detect all bAVMs. Although some angioarchitectural details were missed or misinterpreted when compared to DSA, 4D-CTA evaluation was sufficiently accurate to diagnose the shunt and classify it. Moreover, 4D-CTA adds cross-sectional imaging and perfusion maps, helpful in treatment planning. 4D-CTA appears to be a valuable new adjunct in the non-invasive diagnostic work-up of bAVMs and their follow-up when managed conservatively. (orig.)

  9. Wilson expansion in the minimal subtraction scheme

    International Nuclear Information System (INIS)

    Smirnov, V.A.

    1989-01-01

    The small distance expansion of the product of composite fields is constructed for an arbitrary renormalization procedure of the type of minimal subtraction scheme. Coefficient functions of the expansion are expressed explicitly through the Green functions of composite fields. The expansion has the explicity finite form: the ultraviolet (UV) divergences of the coefficient functions and composite fields are removed by the initial renormalization procedure while the infrared (IR) divergences in massless diagrams with nonvanishing contribution into the coefficient functions are removed by the R-operation which is the IR part of the R-operation. The latter is the generalization of the dimensional renormalization in the case when both UV and IR divergences are present. To derive the expansion, a ''pre-subtracting operator'' is introduced and formulas of the counter-term technique are exploited

  10. Digital subtraction imaging in cardiac investigations

    International Nuclear Information System (INIS)

    Partridge, J.B.; Dickinson, D.F.

    1984-01-01

    The role of digital subtraction imaging (DSI) in the investigation of heart disease in patients of all ages, including neonates, was evaluated by the addition of a continuous fluoroscopy system to an existing, single-plane catheterisation laboratory. In some situations, DSI provided diagnostic images where conventional radiography could not and, in general, provided images of comparable quality to cineangiography. The total dose of contrast medium was usually less than that which would have been required for biplane cineangiography and the dose of radiation was always less. Digital subtraction imaging can make a significant contribution to the investigation of congenital heart disease and has some useful features in the study of acquired heart disease. (author)

  11. Subtracting and Fitting Histograms using Profile Likelihood

    CERN Document Server

    D'Almeida, F M L

    2008-01-01

    It is known that many interesting signals expected at LHC are of unknown shape and strongly contaminated by background events. These signals will be dif cult to detect during the rst years of LHC operation due to the initial low luminosity. In this work, one presents a method of subtracting histograms based on the pro le likelihood function when the background is previously estimated by Monte Carlo events and one has low statistics. Estimators for the signal in each bin of the histogram difference are calculated so as limits for the signals with 68.3% of Con dence Level in a low statistics case when one has a exponential background and a Gaussian signal. The method can also be used to t histograms when the signal shape is known. Our results show a good performance and avoid the problem of negative values when subtracting histograms.

  12. Hardware Implementation of a Bilateral Subtraction Filter

    Science.gov (United States)

    Huertas, Andres; Watson, Robert; Villalpando, Carlos; Goldberg, Steven

    2009-01-01

    A bilateral subtraction filter has been implemented as a hardware module in the form of a field-programmable gate array (FPGA). In general, a bilateral subtraction filter is a key subsystem of a high-quality stereoscopic machine vision system that utilizes images that are large and/or dense. Bilateral subtraction filters have been implemented in software on general-purpose computers, but the processing speeds attainable in this way even on computers containing the fastest processors are insufficient for real-time applications. The present FPGA bilateral subtraction filter is intended to accelerate processing to real-time speed and to be a prototype of a link in a stereoscopic-machine- vision processing chain, now under development, that would process large and/or dense images in real time and would be implemented in an FPGA. In terms that are necessarily oversimplified for the sake of brevity, a bilateral subtraction filter is a smoothing, edge-preserving filter for suppressing low-frequency noise. The filter operation amounts to replacing the value for each pixel with a weighted average of the values of that pixel and the neighboring pixels in a predefined neighborhood or window (e.g., a 9 9 window). The filter weights depend partly on pixel values and partly on the window size. The present FPGA implementation of a bilateral subtraction filter utilizes a 9 9 window. This implementation was designed to take advantage of the ability to do many of the component computations in parallel pipelines to enable processing of image data at the rate at which they are generated. The filter can be considered to be divided into the following parts (see figure): a) An image pixel pipeline with a 9 9- pixel window generator, b) An array of processing elements; c) An adder tree; d) A smoothing-and-delaying unit; and e) A subtraction unit. After each 9 9 window is created, the affected pixel data are fed to the processing elements. Each processing element is fed the pixel value for

  13. Subleading power corrections for N -jettiness subtractions

    Science.gov (United States)

    Moult, Ian; Rothen, Lorena; Stewart, Iain W.; Tackmann, Frank J.; Zhu, Hua Xing

    2017-04-01

    The N -jettiness observable TN provides a way of describing the leading singular behavior of the N -jet cross section in the τ =TN/Q →0 limit, where Q is a hard interaction scale. We consider subleading-power corrections in the τ ≪1 expansion, and employ soft-collinear effective theory to obtain analytic results for the dominant αsτ ln τ and αs2τ ln3τ subleading terms for thrust in e+e- collisions and 0-jettiness for q q ¯-initiated Drell-Yan-like processes at hadron colliders. These results can be used to significantly improve the numerical accuracy and stability of the N -jettiness subtraction technique for performing fixed-order calculations at next-to-leading order and next-to-next-to-leading order. They reduce the size of missing power corrections in the subtractions by an order of magnitude. We also point out that the precise definition of N -jettiness has an important impact on the size of the power corrections and thus the numerical accuracy of the subtractions. The sometimes employed definition of N -jettiness in the hadronic center-of-mass frame suffers from power corrections that grow exponentially with rapidity, causing the power expansion to deteriorate away from central rapidity. This degradation does not occur for the original N -jettiness definition, which explicitly accounts for the boost of the Born process relative to the frame of the hadronic collision, and has a well-behaved power expansion throughout the entire phase space. Integrated over rapidity, using this N -jettiness definition in the subtractions yields another order of magnitude improvement compared to employing the hadronic-frame definition.

  14. Tomosynthesis applied to digital subtraction angiography

    International Nuclear Information System (INIS)

    Kruger, R.A.; Sedaghati, M.; Roy, D.G.; Liu, P.; Nelson, J.A.; Kubal, W.; Del Rio, P.

    1984-01-01

    This extension of the author's previous work on tomographic digital subtraction angiography (DSA) describes the theory of tomosynthetic DSA image reconstruction techniques. In addition to developing the resolution limits resulting from x-ray exposure length and image intensifier field curvature, the authors describe one method of image formation and show tomosynthetic DSA images of animal and human anatomy. Methods for improving the present technique are discussed

  15. Background dose subtraction in personnel dosimetry

    International Nuclear Information System (INIS)

    Picazo, T.; Llorca, N.; Alabau, J.

    1997-01-01

    In this paper it is proposed to consider the mode of the frequency distribution of the low dose dosemeters from each clinic that uses X rays as the background environmental dose that should be subtracted from the personnel dosimetry to evaluate the doses due to practice. The problems and advantages of this indirect method to estimate the environmental background dose are discussed. The results for 60 towns are presented. (author)

  16. Moving object detection using background subtraction

    CERN Document Server

    Shaikh, Soharab Hossain; Chaki, Nabendu

    2014-01-01

    This Springer Brief presents a comprehensive survey of the existing methodologies of background subtraction methods. It presents a framework for quantitative performance evaluation of different approaches and summarizes the public databases available for research purposes. This well-known methodology has applications in moving object detection from video captured with a stationery camera, separating foreground and background objects and object classification and recognition. The authors identify common challenges faced by researchers including gradual or sudden illumination change, dynamic bac

  17. Subtractive Structural Modification of Morpho Butterfly Wings.

    Science.gov (United States)

    Shen, Qingchen; He, Jiaqing; Ni, Mengtian; Song, Chengyi; Zhou, Lingye; Hu, Hang; Zhang, Ruoxi; Luo, Zhen; Wang, Ge; Tao, Peng; Deng, Tao; Shang, Wen

    2015-11-11

    Different from studies of butterfly wings through additive modification, this work for the first time studies the property change of butterfly wings through subtractive modification using oxygen plasma etching. The controlled modification of butterfly wings through such subtractive process results in gradual change of the optical properties, and helps the further understanding of structural optimization through natural evolution. The brilliant color of Morpho butterfly wings is originated from the hierarchical nanostructure on the wing scales. Such nanoarchitecture has attracted a lot of research effort, including the study of its optical properties, its potential use in sensing and infrared imaging, and also the use of such structure as template for the fabrication of high-performance photocatalytic materials. The controlled subtractive processes provide a new path to modify such nanoarchitecture and its optical property. Distinct from previous studies on the optical property of the Morpho wing structure, this study provides additional experimental evidence for the origination of the optical property of the natural butterfly wing scales. The study also offers a facile approach to generate new 3D nanostructures using butterfly wings as the templates and may lead to simpler structure models for large-scale man-made structures than those offered by original butterfly wings. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Physical principles of cardiac digital subtraction angiography

    International Nuclear Information System (INIS)

    Buonocore, E.; Pavlicek, W.

    1986-01-01

    Advances in the applications of computers with standard radiologic equipment have resulted in the development of electronic, or so-called ''film-less'' imaging. This technique, discussed by the authors, has become of particular value in the visualization of the central vascular system and has become known as digital subtraction angiography (DSA). Commercial products have become increasingly available and are capable of converting T.V. signals, obtained by conventional fluorography, to a computed array of digital values. Addition, subtraction, and averaging of this data, result in images with adequate signal-to-noise ratios that achieve detection of low concentrations of contrast media not possible with conventional screen film techniques. Computer subtraction of unnecessary background information improves the conspicuity of the opacified vessels to permit detection of vascular structures containing a concentration of no more than 1-3 percent of contrast media. This improved visualization is possible even with intravenous peripheral injections or reduced amounts of contrast media given intraarterially. With either method of contrast media administration, DSDA has become an excellent means of anatomic demonstration of the heart and great vessels with decreased morbidity and at lower cost

  19. Sky Subtraction with Fiber-Fed Spectrograph

    Science.gov (United States)

    Rodrigues, Myriam

    2017-09-01

    "Historically, fiber-fed spectrographs had been deemed inadequate for the observation of faint targets, mainly because of the difficulty to achieve high accuracy on the sky subtraction. The impossibility to sample the sky in the immediate vicinity of the target in fiber instruments has led to a commonly held view that a multi-object fibre spectrograph cannot achieve an accurate sky subtraction under 1% contrary to their slit counterpart. The next generation of multi-objects spectrograph at the VLT (MOONS) and the planed MOS for the E-ELT (MOSAIC) are fiber-fed instruments, and are aimed to observed targets fainter than the sky continuum level. In this talk, I will present the state-of-art on sky subtraction strategies and data reduction algorithm specifically developed for fiber-fed spectrographs. I will also present the main results of an observational campaign to better characterise the sky spatial and temporal variations ( in particular the continuum and faint sky lines)."

  20. Improving head and neck CTA with hybrid and model-based iterative reconstruction techniques

    NARCIS (Netherlands)

    Niesten, J. M.; van der Schaaf, I. C.; Vos, P. C.; Willemink, MJ; Velthuis, B. K.

    2015-01-01

    AIM: To compare image quality of head and neck computed tomography angiography (CTA) reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (HIR) and model-based iterative reconstruction (MIR) algorithms. MATERIALS AND METHODS: The raw data of 34 studies were

  1. Detection of single-phase CTA occult vessel occlusions in acute ischemic stroke using CT perfusion-based wavelet-transformed angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kunz, Wolfgang G.; Sommer, Wieland H.; Meinel, Felix G.; Ertl-Wagner, Birgit; Thierfelder, Kolja M. [Ludwig-Maximilian-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany); Havla, Lukas; Dietrich, Olaf [Ludwig-Maximilian-University Hospital Munich, Josef Lissner Laboratory for Biomedical Imaging of the Institute for Clinical Radiology, Munich (Germany); Dorn, Franziska [Ludwig-Maximilian-University Hospital Munich, Department of Neuroradiology, Munich (Germany); Buchholz, Grete [Ludwig-Maximilian-University Hospital Munich, Department of Neurology, Munich (Germany)

    2017-06-15

    To determine the detection rate of intracranial vessel occlusions using CT perfusion-based wavelet-transformed angiography (waveletCTA) in acute ischemic stroke patients, in whom single-phase CTA (spCTA) failed to detect an occlusion. Subjects were selected from a cohort of 791 consecutive patients who underwent multiparametric CT including whole-brain CT perfusion. Inclusion criteria were (1) significant cerebral blood flow (CBF) deficit, (2) no evidence of vessel occlusion on spCTA and (3) follow-up-confirmed acute ischemic infarction. waveletCTA was independently analysed by two readers regarding presence and location of vessel occlusions. Logistic regression analysis was performed to identify predictors of waveletCTA-detected occlusions. Fifty-nine patients fulfilled the inclusion criteria. Overall, an occlusion was identified using waveletCTA in 31 (52.5 %) patients with negative spCTA. Out of 47 patients with middle cerebral artery infarction, 27 occlusions (57.4 %) were detected by waveletCTA, mainly located in the M2 (15) and M3 segments (8). The presence of waveletCTA-detected occlusions was associated with larger CBF deficit volumes (odds ratio (OR) = 1.335, p = 0.010) and shorter times from symptom onset (OR = 0.306, p = 0.041). waveletCTA is able to detect spCTA occult vessel occlusions in about half of acute ischemic stroke patients and may potentially identify more patients eligible for endovascular therapy. (orig.)

  2. NNLO jet cross sections by subtraction

    International Nuclear Information System (INIS)

    Somogyi, G.; Bolzoni, P.; Trocsanyi, Z.

    2010-06-01

    We report on the computation of a class of integrals that appear when integrating the so-called iterated singly-unresolved approximate cross section of an earlier NNLO subtraction scheme over the factorised phase space of unresolved partons. The integrated approximate cross section itself can be written as the product of an insertion operator (in colour space) times the Born cross section. We give selected results for the insertion operator for processes with two and three hard partons in the final state. (orig.)

  3. Digital subtraction angiography of the thoracic aorta

    International Nuclear Information System (INIS)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-01-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram

  4. Digital subtraction angiography of the thoracic aorta

    Energy Technology Data Exchange (ETDEWEB)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-02-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram.

  5. Clinical application of digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Morimoto, Tadashi; Kaku, Suiei; Morikawa, Eiji

    1984-01-01

    Intra-arterial digital subtraction angiography (IA-DSA) by the direct puncture of the carotid artery was described with special reference to its techniques, and cases were presented. This method was safe and painless and could be performed repeatedly. Cerebral angiographic images obtained by this method were either superior or fully compatible to the conventional cerebral angiography. It is therefore of great diagnostic value and can replace the conventional method. Furthermore, since the pretreatment is unnecessary and the time required is short, IA-DSA can be used as an adjuvant method for emergency diagnosis. (Namekawa, K)

  6. Intraarterial digital subtraction angiography in neuroradiology

    International Nuclear Information System (INIS)

    Zeumer, H.

    1987-01-01

    Neuroradiology always could make best use of subtraction methods, due to the relative immobility and constant shape of the skull. Arterial DSA now has extended the potential uses while reducing the patient's radiation exposure, the contrast medium dosage and osmolarity. The considerable cut-back in time required for invasive examination has reduced the risk of diagnostic and therapeutic measures. The advantages consisting of immediate image display with high contrast resolution in most of the diagnostic tasks counterbalance the disadvantage of low focal resolution of the DSA in neuroradiology. Interventional neuroradiology today cannot do without i.a. DSA. (orig.) [de

  7. NNLO jet cross sections by subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Somogyi, G.; Bolzoni, P. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Trocsanyi, Z. [CERN, Geneva (Switzerland)

    2010-06-15

    We report on the computation of a class of integrals that appear when integrating the so-called iterated singly-unresolved approximate cross section of an earlier NNLO subtraction scheme over the factorised phase space of unresolved partons. The integrated approximate cross section itself can be written as the product of an insertion operator (in colour space) times the Born cross section. We give selected results for the insertion operator for processes with two and three hard partons in the final state. (orig.)

  8. NNLO jet cross sections by subtraction

    CERN Document Server

    Somogyi, Gabor; Trocsanyi, Zoltan

    2010-01-01

    We report on the computation of a class of integrals that appear when integrating the so-called iterated singly-unresolved approximate cross section of the NNLO subtraction scheme of [1-4], over the factorised phase space of unresolved partons. The integrated approximate cross section itself can be written as the product of an insertion operator (in colour space) times the Born cross section. We give selected results for the insertion operator for processes with two and three hard partons in the final state.

  9. Computed tomography lung iodine contrast mapping by image registration and subtraction

    Science.gov (United States)

    Goatman, Keith; Plakas, Costas; Schuijf, Joanne; Beveridge, Erin; Prokop, Mathias

    2014-03-01

    Pulmonary embolism (PE) is a relatively common and potentially life threatening disease, affecting around 600,000 people annually in the United States alone. Prompt treatment using anticoagulants is effective and saves lives, but unnecessary treatment risks life threatening haemorrhage. The specificity of any diagnostic test for PE is therefore as important as its sensitivity. Computed tomography (CT) angiography is routinely used to diagnose PE. However, there are concerns it may over-report the condition. Additional information about the severity of an occlusion can be obtained from an iodine contrast map that represents tissue perfusion. Such maps tend to be derived from dual-energy CT acquisitions. However, they may also be calculated by subtracting pre- and post-contrast CT scans. Indeed, there are technical advantages to such a subtraction approach, including better contrast-to-noise ratio for the same radiation dose, and bone suppression. However, subtraction relies on accurate image registration. This paper presents a framework for the automatic alignment of pre- and post-contrast lung volumes prior to subtraction. The registration accuracy is evaluated for seven subjects for whom pre- and post-contrast helical CT scans were acquired using a Toshiba Aquilion ONE scanner. One hundred corresponding points were annotated on the pre- and post-contrast scans, distributed throughout the lung volume. Surface-to-surface error distances were also calculated from lung segmentations. Prior to registration the mean Euclidean landmark alignment error was 2.57mm (range 1.43-4.34 mm), and following registration the mean error was 0.54mm (range 0.44-0.64 mm). The mean surface error distance was 1.89mm before registration and 0.47mm after registration. There was a commensurate reduction in visual artefacts following registration. In conclusion, a framework for pre- and post-contrast lung registration has been developed that is sufficiently accurate for lung subtraction

  10. Sensitivity of CTA to dark matter signals from the Galactic Center

    Energy Technology Data Exchange (ETDEWEB)

    Pierre, Mathias [Département Physique, École Normale Supérieure de Cachan, 61 Avenue du Président Wilson, Cachan, 94230 France (France); Siegal-Gaskins, Jennifer M. [California Institute of Technology, 1200 E. California Blvd., Pasadena, CA, 91125 (United States); Scott, Pat, E-mail: mathias.pierre@ens-cachan.fr, E-mail: jsg@tapir.caltech.edu, E-mail: patscott@physics.mcgill.ca [Department of Physics, McGill University, 3600 Rue University, Montréal, Québec, H3A 2T8 Canada (Canada)

    2014-06-01

    The Galactic Center is one of the most promising targets for indirect detection of dark matter with gamma rays. We investigate the sensitivity of the upcoming Cherenkov Telescope Array (CTA) to dark matter annihilation and decay in the Galactic Center. As the inner density profile of the Milky Way's dark matter halo is uncertain, we study the impact of the slope of the Galactic density profile, inwards of the Sun, on the prospects for detecting a dark matter signal with CTA. Adopting the Ring Method to define the signal and background regions in an ON-OFF analysis approach, we find that the sensitivity achieved by CTA to annihilation signals is strongly dependent on the inner profile slope, whereas the dependence is more mild in the case of dark matter decay. Surprisingly, we find that the optimal choice of signal and background regions is virtually independent of the assumed density profile. For the fiducial case of a Navarro-Frenk-White profile, we find that CTA will be able to probe annihilation cross-sections well below the canonical thermal relic value for dark matter masses from a few tens of GeV up to ∼ 5 TeV for annihilation to τ{sup +}τ{sup −}, and will achieve only a slightly weaker sensitivity for annihilation to b b-bar or μ{sup +}μ{sup −}. CTA will improve significantly on current sensitivity to annihilation signals for dark matter masses above ∼ 100 GeV, covering parameter space that is complementary to that probed by searches with the Fermi Large Area Telescope. The interpretation of apparent excesses in the measured cosmic-ray electron and positron spectra as signals of dark matter decay will also be testable with CTA observations of the Galactic Center. We demonstrate that both for annihilation and for decay, including spectral information for hard channels (such as μ{sup +}μ{sup −} and τ{sup +}τ{sup −}) leads to enhanced sensitivity for dark matter masses above m{sub DM} ∼ 200 GeV.

  11. Sensitivity of CTA to dark matter signals from the Galactic Center

    International Nuclear Information System (INIS)

    Pierre, Mathias; Siegal-Gaskins, Jennifer M.; Scott, Pat

    2014-01-01

    The Galactic Center is one of the most promising targets for indirect detection of dark matter with gamma rays. We investigate the sensitivity of the upcoming Cherenkov Telescope Array (CTA) to dark matter annihilation and decay in the Galactic Center. As the inner density profile of the Milky Way's dark matter halo is uncertain, we study the impact of the slope of the Galactic density profile, inwards of the Sun, on the prospects for detecting a dark matter signal with CTA. Adopting the Ring Method to define the signal and background regions in an ON-OFF analysis approach, we find that the sensitivity achieved by CTA to annihilation signals is strongly dependent on the inner profile slope, whereas the dependence is more mild in the case of dark matter decay. Surprisingly, we find that the optimal choice of signal and background regions is virtually independent of the assumed density profile. For the fiducial case of a Navarro-Frenk-White profile, we find that CTA will be able to probe annihilation cross-sections well below the canonical thermal relic value for dark matter masses from a few tens of GeV up to ∼ 5 TeV for annihilation to τ + τ − , and will achieve only a slightly weaker sensitivity for annihilation to b b-bar or μ + μ − . CTA will improve significantly on current sensitivity to annihilation signals for dark matter masses above ∼ 100 GeV, covering parameter space that is complementary to that probed by searches with the Fermi Large Area Telescope. The interpretation of apparent excesses in the measured cosmic-ray electron and positron spectra as signals of dark matter decay will also be testable with CTA observations of the Galactic Center. We demonstrate that both for annihilation and for decay, including spectral information for hard channels (such as μ + μ − and τ + τ − ) leads to enhanced sensitivity for dark matter masses above m DM ∼ 200 GeV

  12. Statistical coronary motion models for 2D + t/3D registration of X-ray coronary angiography and CTA

    DEFF Research Database (Denmark)

    Baka, N.; Metz, C. T.; Schultz, C.

    2013-01-01

    Accurate alignment of intra-operative X-ray coronary angiography (XA) and pre-operative cardiac CT angiography (CTA) may improve procedural success rates of minimally invasive coronary interventions for patients with chronic total occlusions. It was previously shown that incorporating patient...... specific coronary motion extracted from 4D CTA increases the robustness of the alignment. However, pre-operative CTA is often acquired with gating at end-diastole, in which case patient specific motion is not available. For such cases, we investigate the possibility of using population based coronary...

  13. Parallel decompositions of Mueller matrices and polarimetric subtraction

    Directory of Open Access Journals (Sweden)

    Gil J.J.

    2010-06-01

    Full Text Available From a general formulation of the physically realizable parallel decompositions of the Mueller matrix M of a given depolarizing system, a procedure for determining the set of pure Mueller matrices susceptible to be subtracted from M is presented. This procedure provides a way to check if a given pure Mueller matrix N can be subtracted from M or not. If this check is positive, the value of the relative cross section of the subtracted component is also determined.

  14. Spectral amplitude coding OCDMA using and subtraction technique.

    Science.gov (United States)

    Hasoon, Feras N; Aljunid, S A; Samad, M D A; Abdullah, Mohamad Khazani; Shaari, Sahbudin

    2008-03-20

    An optical decoding technique is proposed for a spectral-amplitude-coding-optical code division multiple access, namely, the AND subtraction technique. The theory is being elaborated and experimental results have been done by comparing a double-weight code against the existing code, Hadamard. We have proved that the and subtraction technique gives better bit error rate performance than the conventional complementary subtraction technique against the received power level.

  15. System testing software deployments using Docker and Kubernetes in gitlab CI: EOS + CTA use case

    CERN Document Server

    CERN. Geneva

    2017-01-01

    It needs to be seamlessly integrated with `EOS`, which has become the de facto disk storage system at CERN. `CTA` and `EOS` integration requires parallel development of features in both software that needs to be **synchronized and systematically tested** on a specific distributed development infrastructure for each commit in the code base. This presentation describes the full gitlab continuous integration work flow that builds, tests, deploys and run system tests of the full software stack in docker containers on our specific kubernetes infrastructure.

  16. ACID Astronomical and Physics Cloud Interactive Desktop: A Prototype of VUI for CTA Science Gateway

    Science.gov (United States)

    Massimino, P.; Costa, A.; Becciani, U.; Vuerli, C.; Bandieramonte, M.; Petta, C.; Riggi, S.; Sciacca, E.; Vitello, F.; Pistagna, C.

    2014-05-01

    The Astronomical & Physics Cloud Interactive Desktop, developed for the prototype of CTA Science Gateway in Catania, Italy, allows to use many software packages without any installation on the local desktop. The users will be able to exploit, if applicable, the native Graphical User Interface (GUI) of the programs that are available in the ACID environment. For using interactively the remote programs, ACID exploits an "ad hoc" VNC-based User Interface (VUI).

  17. Updates to Constituent Subtraction in Heavy Ions at CMS

    CERN Document Server

    CMS Collaboration

    2018-01-01

    The latest upgrades and performance of constituent subtraction in 5.02 TeV PbPb collisions is presented. The constituent subtraction is extended through the full tracker acceptance, increasing the rapidity reach of correctly subtracted jets. A modulation in azimuthal angle is added to the subtraction, accounting for flow on an event-by-event basis and improving jet energy resolution. Closure of jet energy scale after corrections and jet energy resolution is shown for R=0.4 and R=0.8 jets, the latter for the first time in CMS Heavy-Ions.

  18. Study on scan timing using a test injection method in head CTA

    International Nuclear Information System (INIS)

    Sekito, Yuichi; Sanada, Hidenori

    2005-01-01

    In head computed tomographic angiography (CTA), circulation from arterial phase to venous phase is more rapid than that in other regions. Therefore, it is necessary to determine correct scan timing to obtain ideal CTA images. A test injection method makes it possible to set correct scan timing from the time density curve (TDC) for each subject. The method, however, has a weak point that is a time lag in an arrival time at peak point of contrast medium on TDC between the test injection and the primary examination because of the difference in total volume of contrast medium used. The purpose of this study calculated the delay time on the TDC in both scans. We used the test injection method and the bolus tracking method in the primary examination. The average errors in start time (Δt1) and slope change time (Δt2) of the contrast medium on the TDC between test injection and primary examination were 0.15 sec and 3.05 sec, respectively. The results indicated that it was important to grasp the delay time in start time and peak arrival time of the contrast medium between test injection and primary examination to obtain ideal images in head CTA. (author)

  19. Minimally invasive vascular imaging using 3D-CTA and 3D-MRA. Update

    International Nuclear Information System (INIS)

    Hayashi, Hiromitsu; Kawamata, Hiroshi; Takagi, Ryo; Amano, Yasuo; Wakabayashi, Hiroyuki; Ichikawa, Kazuo; Kumazaki, Tatsuo

    1998-01-01

    Conventional angiography is considered the standard of reference for diagnostic imaging of vascular diseases with respect to its temporal and spatial resolution. This procedure, however is invasive and repeated studies are difficult, and arterial complications are occasionally associated in catheter-based conventional angiography. Recent advances in diagnostic imaging have facilitated three-dimensional CT angiography (3D-CTA) using the volumetric acquisition capabilities inherent in spiral CT and three-dimensional MR angiography (3D-MRA) using the 3D gradient-echo sequence with a bolus injection of Gd-DTPA. These techniques can provide vascular images exceedingly similar to conventional angiograms within a short acquisition time. 3D-CTA and 3D-MRA are considered to be promising, minimally invasive methods for obtaining images of the vasculature, and alternatives to catheter angiography. This study reviews the current status of 3D-CTA and 3D-MRA, with emphasis on the clinical usefulness of three-dimensional diagnostic imaging for the evaluation of diverse vascular pathologies. (author)

  20. Photon Subtraction by Many-Body Decoherence

    DEFF Research Database (Denmark)

    Murray, C. R.; Mirgorodskiy, I.; Tresp, C.

    2018-01-01

    We experimentally and theoretically investigate the scattering of a photonic quantum field from another stored in a strongly interacting atomic Rydberg ensemble. Considering the many-body limit of this problem, we derive an exact solution to the scattering-induced spatial decoherence of multiple...... stored photons, allowing for a rigorous understanding of the underlying dissipative quantum dynamics. Combined with our experiments, this analysis reveals a correlated coherence-protection process in which the scattering from one excitation can shield all others from spatial decoherence. We discuss how...... this effect can be used to manipulate light at the quantum level, providing a robust mechanism for single-photon subtraction, and experimentally demonstrate this capability....

  1. NNLO jet cross sections by subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Somogyi, G.; Bolzoni, P. [DESY, Platanenallee 6, D-15738 Zeuthen (Germany); Trocsanyi, Z. [CERN PH-TH, on leave from University of Debrecen and Institute of Nuclear Research of HAS, H-4001 P.O.Box 51 (Hungary)

    2010-08-15

    We report on the computation of a class of integrals that appear when integrating the so-called iterated singly-unresolved approximate cross section of the NNLO subtraction scheme of Refs. [G. Somogyi, Z. Trocsanyi, and V. Del Duca, JHEP 06, 024 (2005), (arXiv:hep-ph/0502226); G. Somogyi and Z. Trocsanyi, (2006), (arXiv:hep-ph/0609041); G. Somogyi, Z. Trocsanyi, and V. Del Duca, JHEP 01, 070 (2007), (arXiv:hep-ph/0609042); G. Somogyi and Z. Trocsanyi, JHEP 01, 052 (2007), (arXiv:hep-ph/0609043)] over the factorised phase space of unresolved partons. The integrated approximate cross section itself can be written as the product of an insertion operator (in colour space) times the Born cross section. We give selected results for the insertion operator for processes with two and three hard partons in the final state.

  2. NNLO jet cross sections by subtraction

    International Nuclear Information System (INIS)

    Somogyi, G.; Bolzoni, P.; Trocsanyi, Z.

    2010-01-01

    We report on the computation of a class of integrals that appear when integrating the so-called iterated singly-unresolved approximate cross section of the NNLO subtraction scheme of Refs. [G. Somogyi, Z. Trocsanyi, and V. Del Duca, JHEP 06, 024 (2005), (arXiv:hep-ph/0502226); G. Somogyi and Z. Trocsanyi, (2006), (arXiv:hep-ph/0609041); G. Somogyi, Z. Trocsanyi, and V. Del Duca, JHEP 01, 070 (2007), (arXiv:hep-ph/0609042); G. Somogyi and Z. Trocsanyi, JHEP 01, 052 (2007), (arXiv:hep-ph/0609043)] over the factorised phase space of unresolved partons. The integrated approximate cross section itself can be written as the product of an insertion operator (in colour space) times the Born cross section. We give selected results for the insertion operator for processes with two and three hard partons in the final state.

  3. Myocardial perfusion imaging by digital subtraction angiography

    International Nuclear Information System (INIS)

    Kadowaki, Hiroyuki; Ishikawa, Kinji; Ogai, Toshihiro; Katori, Ryo

    1986-01-01

    Several methods of digital subtraction angiography (DSA) were compared to determine which could better visualize regional myocardial perfusion using coronary angiography in seven patients with myocardial infarction, two with angina pectoris and five with normal coronary arteries. Satisfactory DSA was judged to be achieved if the shape of the heart on the mask film was identical to that on the live film and if both films were exactly superimposed. To obtain an identical mask film in the shape of each live film, both films were selected from the following three phases of the cardiac cycle; 1) at the R wave of the electrocardiogram, 2) 100 msec before the R wave, and 3) 200 msec before the R wave. The last two were superior for obtaining mask and live films which were similar in shape, because the cardiac motion in these phases was relatively small. Using these mask and live films, DSA was performed either with the continuous image mode (CI mode) or the time interval difference mode (TID mode). The overall perfusion of contrast medium through the artery to the vein was adequately visualized using the CI mode. Passage of contrast medium through the artery, capillary and vein was visualized at each phase using TID mode. Subtracted images were displayed and photographed, and the density of the contrast medium was adequate to display contour lines as in a relief map. Using this DSA, it was found that regional perfusion of the contrast medium was not always uniform in normal subjects, depending on the typography of the coronary artery. In all patients with anterior myocardial infarction, low perfusion was observed at the infarcted portion compared to the non-infarcted myocardium. In patients with inferior myocardial infarction, this low perfusion area was not observed because right coronary angiography was not subjected to DSA in this study. (J.P.N.)

  4. [Myocardial perfusion imaging by digital subtraction angiography].

    Science.gov (United States)

    Kadowaki, H; Ishikawa, K; Ogai, T; Katori, R

    1986-03-01

    Several methods of digital subtraction angiography (DSA) were compared to determine which could better visualize regional myocardial perfusion using coronary angiography in seven patients with myocardial infarction, two with angina pectoris and five with normal coronary arteries. Satisfactory DSA was judged to be achieved if the shape of the heart on the mask film was identical to that on the live film and if both films were exactly superimposed. To obtain an identical mask film in the shape of each live film, both films were selected from the following three phases of the cardiac cycle; at the R wave of the electrocardiogram, 100 msec before the R wave, and 200 msec before the R wave. The last two were superior for obtaining mask and live films which were similar in shape, because the cardiac motion in these phases was relatively small. Using these mask and live films, DSA was performed either with the continuous image mode (CI mode) or the time interval difference mode (TID mode). The overall perfusion of contrast medium through the artery to the vein was adequately visualized using the CI mode. Passage of contrast medium through the artery, capillary and vein was visualized at each phase using TID mode. Subtracted images were displayed and photographed, and the density of the contrast medium was adequate to display contour lines as in a relief map. Using this DSA, it was found that regional perfusion of the contrast medium was not always uniform in normal subjects, depending on the typography of the coronary artery.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Visualisation of bony and vascular structures via digital subtraction images upon the amount of anatomic background

    International Nuclear Information System (INIS)

    Hinz, A.; Scholz, A.; Zwicker, C.

    1992-01-01

    We examined the loss of contrast leaving a part of the anatomic background in digital subtraction angiography by visual analysis and densitometry. We observed a greater loss of the quality at the representation of the bone below than above an amount of anatomic background of 60%. The loss of quality at the representation of the vessels decreases more above than below an anatomical background of 45%. We think that, depending on the clinical problem, an anatomical background between 15 and 30% should be left. (orig.) [de

  6. Absence of Protoheme IX Farnesyltransferase CtaB Causes Virulence Attenuation but Enhances Pigment Production and Persister Survival in MRSA.

    Science.gov (United States)

    Xu, Tao; Han, Jian; Zhang, Jia; Chen, Jiazhen; Wu, Nan; Zhang, Wenhong; Zhang, Ying

    2016-01-01

    The membrane protein CtaB in S. aureus is a protoheme IX farnesyltransferase involved in the synthesis of the heme containing terminal oxidases of bacterial respiratory chain. In this study, to assess the role of CtaB in S. aureus virulence, pigment production, and persister formation, we constructed a ctaB mutant in the methicillin-resistant Staphylococcus aureus (MRSA) strain USA500. We found that deletion of ctaB attenuated growth and virulence in mice but enhanced pigment production and formation of quinolone tolerant persister cells in stationary phase. RNA-seq analysis showed that deletion of ctaB caused decreased transcription of several virulence genes including RNAIII which is consistent with its virulence attenuation. In addition, transcription of 20 ribosomal genes and 24 genes involved in amino acid biosynthesis was significantly down-regulated in the ctaB knockout mutant compared with the parent strain. These findings suggest the importance of heme biosynthesis in virulence and persister formation of S. aureus .

  7. Digital subtraction radiographic analysis of the combination of bioabsorbable membrane and bovine morphogenetic protein pool in human periodontal infrabony defects

    Directory of Open Access Journals (Sweden)

    Maria do Carmo Machado Guimarães

    2010-08-01

    Full Text Available OBJECTIVES: This study assessed the bone density gain and its relationship with the periodontal clinical parameters in a case series of a regenerative therapy procedure. MATERIAL AND METHODS: Using a split-mouth study design, 10 pairs of infrabony defects from 15 patients were treated with a pool of bovine bone morphogenetic proteins associated with collagen membrane (test sites or collagen membrane only (control sites. The periodontal healing was clinically and radiographically monitored for six months. Standardized pre-surgical and 6-month postoperative radiographs were digitized for digital subtraction analysis, which showed relative bone density gain in both groups of 0.034 ± 0.423 and 0.105 ± 0.423 in the test and control group, respectively (p>0.05. RESULTS: As regards the area size of bone density change, the influence of the therapy was detected in 2.5 mm² in the test group and 2 mm² in the control group (p>0.05. Additionally, no correlation was observed between the favorable clinical results and the bone density gain measured by digital subtraction radiography (p>0.05. CONCLUSIONS: The findings of this study suggest that the clinical benefit of the regenerative therapy observed did not come with significant bone density gains. Long-term evaluation may lead to a different conclusions.

  8. Tomography of photon-added and photon-subtracted states

    NARCIS (Netherlands)

    Bazrafkan, MR; Man'ko, [No Value

    The purpose of this paper is to introduce symplectic and optical tomograms of photon-added and photon-subtracted quantum states. Explicit relations for the tomograms of photon-added and photon-subtracted squeezed coherent states and squeezed number states are obtained. Generating functions for the

  9. Bone tumor

    Science.gov (United States)

    Tumor - bone; Bone cancer; Primary bone tumor; Secondary bone tumor; Bone tumor - benign ... The cause of bone tumors is unknown. They often occur in areas of the bone that grow rapidly. Possible causes include: Genetic defects ...

  10. An automated subtraction of NLO EW infrared divergences

    Energy Technology Data Exchange (ETDEWEB)

    Schoenherr, Marek [CERN, Theoretical Physics Department, Geneva (Switzerland)

    2018-02-15

    In this paper a generalisation of the Catani-Seymour dipole subtraction method to next-to-leading order electroweak calculations is presented. All singularities due to photon and gluon radiation off both massless and massive partons in the presence of both massless and massive spectators are accounted for. Particular attention is paid to the simultaneous subtraction of singularities of both QCD and electroweak origin which are present in the next-to-leading order corrections to processes with more than one perturbative order contributing at Born level. Similarly, embedding non-dipole-like photon splittings in the dipole subtraction scheme discussed. The implementation of the formulated subtraction scheme in the framework of the Sherpa Monte-Carlo event generator, including the restriction of the dipole phase space through the α-parameters and expanding its existing subtraction for NLO QCD calculations, is detailed and numerous internal consistency checks validating the obtained results are presented. (orig.)

  11. Temporal subtraction of dual-energy chest radiographs

    International Nuclear Information System (INIS)

    Armato, Samuel G. III; Doshi, Devang J.; Engelmann, Roger; Caligiuri, Philip; MacMahon, Heber

    2006-01-01

    Temporal subtraction and dual-energy imaging are two enhanced radiography techniques that are receiving increased attention in chest radiography. Temporal subtraction is an image processing technique that facilitates the visualization of pathologic change across serial chest radiographic images acquired from the same patient; dual-energy imaging exploits the differential relative attenuation of x-ray photons exhibited by soft-tissue and bony structures at different x-ray energies to generate a pair of images that accentuate those structures. Although temporal subtraction images provide a powerful mechanism for enhancing visualization of subtle change, misregistration artifacts in these images can mimic or obscure abnormalities. The purpose of this study was to evaluate whether dual-energy imaging could improve the quality of temporal subtraction images. Temporal subtraction images were generated from 100 pairs of temporally sequential standard radiographic chest images and from the corresponding 100 pairs of dual-energy, soft-tissue radiographic images. The registration accuracy demonstrated in the resulting temporal subtraction images was evaluated subjectively by two radiologists. The registration accuracy of the soft-tissue-based temporal subtraction images was rated superior to that of the conventional temporal subtraction images. Registration accuracy also was evaluated objectively through an automated method, which achieved an area-under-the-ROC-curve value of 0.92 in the distinction between temporal subtraction images that demonstrated clinically acceptable and clinically unacceptable registration accuracy. By combining dual-energy soft-tissue images with temporal subtraction, misregistration artifacts can be reduced and superior image quality can be obtained

  12. An evaluation of the subtraction photoshop software accuracy to detect minor changes in optical density by radiovisiography

    Directory of Open Access Journals (Sweden)

    Talaeipour AR.

    2004-06-01

    Full Text Available Statement of Problem: Subtraction is a newly presented radiography technique to detect minor density"nchanges that are not visible by conventional radiography."nPurpose: The aim of this In-vitro study was to evaluate the efficacy of photoshop subtraction software for"ndetecting minor density changes between two dental images."nMaterials and Methods: In this research, five dried human mandibles were held in fixed position while thin"naluminium sheets were superimposed on each mandible on the 1th and 2nd molar teeth regions."nA reference image, without aluminium sheet placement, was obtained from each mandible subsequently series"nconsist of 20 images with aluminium sheets, ranging from 50p. to "5Q0"x were recorded by radiovisiography"n(RVG system. Initial images were subtracted from subsequent ones by Photoshop subtraction software. The"ndifference in density between the two images at the 1st and 2nd molar sites was related to the aluminium"nsheets. The optical density of aluminium sheets was determined by densitometer."nResults: In the present study, 6.6% of the optical density changes of the minimum aluminium thickness as"n300u. could be detected by photoshop software software."nConclusion: The findings of this study showed that the accuracy of photoshop subtraction software was equal"nto that of the conventional subtraction softwares. Additionally, the accuracy of this software was proved to be"nsuitable for clinical investigations of small localized changes in alveolar bone.

  13. Optimization of the Reconstruction Interval in Neurovascular 4D-CTA Imaging

    Science.gov (United States)

    Hoogenboom, T.C.H.; van Beurden, R.M.J.; van Teylingen, B.; Schenk, B.; Willems, P.W.A.

    2012-01-01

    Summary Time resolved whole brain CT angiography (4D-CTA) is a novel imaging technology providing information regarding blood flow. One of the factors that influence the diagnostic value of this examination is the temporal resolution, which is affected by the gantry rotation speed during acquisition and the reconstruction interval during post-processing. Post-processing determines the time spacing between two reconstructed volumes and, unlike rotation speed, does not affect radiation burden. The data sets of six patients who underwent a cranial 4D-CTA were used for this study. Raw data was acquired using a 320-slice scanner with a rotation speed of 2 Hz. The arterial to venous passage of an intravenous contrast bolus was captured during a 15 s continuous scan. The raw data was reconstructed using four different reconstruction-intervals: 0.2, 0.3, 0.5 and 1.0 s. The results were rated by two observers using a standardized score sheet. The appearance of each lesion was rated correctly in all readings. Scoring for quality of temporal resolution revealed a stepwise improvement from the 1.0 s interval to the 0.3 s interval, while no discernable improvement was noted between the 0.3 s and 0.2 s interval. An increase in temporal resolution may improve the diagnostic quality of cranial 4D-CTA. Using a rotation speed of 0.5 s, the optimal reconstruction interval appears to be 0.3 s, beyond which, changes can no longer be discerned. PMID:23217631

  14. Low-tube-voltage selection for triple-rule-out CTA: relation to patient size

    Energy Technology Data Exchange (ETDEWEB)

    Takx, Richard A.P. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Krissak, Radko [Medical Faculty Mannheim - Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim (Germany); Hufeland Klinikum GmbH, Department of Diagnostic and Interventional Radiology, Bad Langensalza (Germany); Fink, Christian [Medical Faculty Mannheim - Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim (Germany); General Hospital Celle, Department of Radiology, Celle (Germany); Bachmann, Valentin; Henzler, Thomas; Meyer, Mathias; Schoenberg, Stefan O. [Medical Faculty Mannheim - Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim (Germany); Nance, John W. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Apfaltrer, Paul [Medical Faculty Mannheim - Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim (Germany); Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria)

    2017-06-15

    To investigate the relationship between image quality and patient size at 100 kilovoltage (kV) compared to 120 kV ECG-gated Triple-Rule-Out CT angiography (TRO-CTA). We retrospectively included 73 patients (age 64 ± 14 years) who underwent retrospective ECG-gated chest CTA. 40 patients were scanned with 100 kV while 33 patients with 120 kV. Body mass index (BMI), patients' chest circumference (PC) and thoracic surface area (TSA) were recorded. Quantitative image quality was assessed as vascular attenuation in the ascending aorta (AA), pulmonary trunk (PA) and left coronary artery (LCA) and the signal-to-noise ratio (SNR) in the AA. There was no significant difference in BMI (26.0 ± 4.6 vs. 28.0 ± 6.7 kg/m{sup 2}), PC (103 ± 7 vs. 104 ± 10 cm{sup 2}) and TSA (92 ± 15 vs. 91 ± 19 cm{sup 2}) between 100 kV and 120 kV group. Mean vascular attenuation was significantly higher in the 100 kV compared to the 120 kV group (AA 438 vs. 354 HU, PA 460 vs. 349 HU, LCA 370 vs. 299 HU all p < 0.001). SNR was not significantly different, even after adjusting for patient size. Radiation dose was significantly lower in the 100 kV group (10.7 ± 4.1 vs. 20.7 ± 10.7 mSv; p < 0.001). 100 kV TRO-CTA is feasible in normal-to-overweight patients while maintaining image quality and achieving substantial dose reduction. (orig.)

  15. Cardiac complications of intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Neergaard, K.; Dirksen, K.L.; Andersen, I.; Galloee, A.M.; Madsen, E.B.

    1989-01-01

    In a prospective study of 103 patients the incidence of cardiac events during intravenous digital subtraction angiography (i.v. DSA) was investigated. Of 103 patients 17 had known ischaemic heart disease. The examination was performed with an ionic contrast medium, Urografin 76% (sodium megluminediatrizoate), administered by bolus injection into the right atrium. Patients with severe cardiac disease were examined only if the procedure was considered of vital importance. Cardiac events were defined as ST-segment changes of more than 0.1 mV, changes in heart rate of more than 20%, arrhythmias and such symptoms as chest pain and dyspnoea. Ischaemic ST-segment changes during i.v. DSA were observed in approximately 20% of the patients and were not related to the presence of known ischaemic heart disease. Three patients developed angina during the procedure. Among 12 patients with known angina only one patient developed angina during the procedure. In this study chest pain was infrequent (3%), but there was a relative high frequency of ECG changes (20%) not related to patients with ischaemic heart disease only. It is concluded that there is a risk of cardiac events during i.v. DSA, but the risk is not increased in patients with known ischaemic heart disease (if they do not suffer from congestive heart failure) as compared with other patients without known ischaemic heart disease. (orig.)

  16. Diffraction, chopping, and background subtraction for LDR

    Science.gov (United States)

    Wright, Edward L.

    1988-01-01

    The Large Deployable Reflector (LDR) will be an extremely sensitive infrared telescope if the noise due to the photons in the large thermal background is the only limiting factor. For observations with a 3 arcsec aperture in a broadband at 100 micrometers, a 20-meter LDR will emit 10(exp 12) per second, while the photon noise limited sensitivity in a deep survey observation will be 3,000 photons per second. Thus the background subtraction has to work at the 1 part per billion level. Very small amounts of scattered or diffracted energy can be significant if they are modulated by the chopper. The results are presented for 1-D and 2-D diffraction calculations for the lightweight, low-cost LDR concept that uses an active chopping quaternary to correct the wavefront errors introduced by the primary. Fourier transforms were used to evaluate the diffraction of 1 mm waves through this system. Unbalanced signals due to dust and thermal gradients were also studied.

  17. Accessing the diffracted wavefield by coherent subtraction

    Science.gov (United States)

    Schwarz, Benjamin; Gajewski, Dirk

    2017-10-01

    Diffractions have unique properties which are still rarely exploited in common practice. Aside from containing subwavelength information on the scattering geometry or indicating small-scale structural complexity, they provide superior illumination compared to reflections. While diffraction occurs arguably on all scales and in most realistic media, the respective signatures typically have low amplitudes and are likely to be masked by more prominent wavefield components. It has been widely observed that automated stacking acts as a directional filter favouring the most coherent arrivals. In contrast to other works, which commonly aim at steering the summation operator towards fainter contributions, we utilize this directional selection to coherently approximate the most dominant arrivals and subtract them from the data. Supported by additional filter functions which can be derived from wave front attributes gained during the stacking procedure, this strategy allows for a fully data-driven recovery of faint diffractions and makes them accessible for further processing. A complex single-channel field data example recorded in the Aegean sea near Santorini illustrates that the diffracted background wavefield is surprisingly rich and despite the absence of a high channel count can still be detected and characterized, suggesting a variety of applications in industry and academia.

  18. NNLO jet cross sections by subtraction

    Science.gov (United States)

    Somogyi, G.; Bolzoni, P.; Trócsányi, Z.

    2010-08-01

    We report on the computation of a class of integrals that appear when integrating the so-called iterated singly-unresolved approximate cross section of the NNLO subtraction scheme of Refs. [G. Somogyi, Z. Trócsányi, and V. Del Duca, JHEP 06, 024 (2005), arXiv:hep-ph/0502226; G. Somogyi and Z. Trócsányi, (2006), arXiv:hep-ph/0609041; G. Somogyi, Z. Trócsányi, and V. Del Duca, JHEP 01, 070 (2007), arXiv:hep-ph/0609042; G. Somogyi and Z. Trócsányi, JHEP 01, 052 (2007), arXiv:hep-ph/0609043] over the factorised phase space of unresolved partons. The integrated approximate cross section itself can be written as the product of an insertion operator (in colour space) times the Born cross section. We give selected results for the insertion operator for processes with two and three hard partons in the final state.

  19. Búsqueda de Sitios para CTA: Análisis de Datos Satelitales

    Science.gov (United States)

    Suárez, A. E.; Medina, M. C.; Romero, G. E.

    The CTA Consortium has decided to implement a systematic search for sites for the Observatory. This search will be made in two different steps. The first one consists of a general determination of the possible sites on the basis of some very basic selection criteria, such as geographic latitude, altitude and extension of the flat area needed. For those sites passing these criteria, a more intensive characterization should be made, using available satellite data, together with existing ground or air-based measurements. In this work we compare the behavior of different sites analyzing the aerosol content and the total precipitable water vapor, measured by MODIS instrument. FULL TEXT IN SPANISH

  20. Longitudinal development of subtraction performance in elementary school.

    Science.gov (United States)

    Artemenko, Christina; Pixner, Silvia; Moeller, Korbinian; Nuerk, Hans-Christoph

    2017-10-05

    A major goal of education in elementary mathematics is the mastery of arithmetic operations. However, research on subtraction is rather scarce, probably because subtraction is often implicitly assumed to be cognitively similar to addition, its mathematical inverse. To evaluate this assumption, we examined the relation between the borrow effect in subtraction and the carry effect in addition, and the developmental trajectory of the borrow effect in children using a choice reaction paradigm in a longitudinal study. In contrast to the carry effect in adults, carry and borrow effects in children were found to be categorical rather than continuous. From grades 3 to 4, children became more proficient in two-digit subtraction in general, but not in performing the borrow operation in particular. Thus, we observed no specific developmental progress in place-value computation, but a general improvement in subtraction procedures. Statement of contribution What is already known on this subject? The borrow operation increases difficulty in two-digit subtraction in adults. The carry effect in addition, as the inverse operation of borrowing, comprises categorical and continuous processing characteristics. What does this study add? In contrast to the carry effect in adults, the borrow and carry effects are categorical in elementary school children. Children generally improve in subtraction performance from grades 3 to 4 but do not progress in place-value computation in particular. © 2017 The British Psychological Society.

  1. Digital contrast subtraction radiography for proximal caries diagnosis

    International Nuclear Information System (INIS)

    Kang, Byung Cheol; Yoon, Suk Ja

    2002-01-01

    To determine whether subtraction images utilizing contrast media can improve the diagnostic performance of proximal caries diagnosis compared to conventional periapical radiographic images. Thirty-six teeth with 57 proximal surfaces were radiographied using a size no.2 RVG-ui sensor (Trophy Radiology, Marne-la-Vallee, France). The teeth immersed in water-soluble contrast media and subtraction images were taken. Each tooth was then sectioned for histologic examination. The digital radiographic images and subtraction images were examined and interpreted by three dentists for proximal caries. The results of the proximal caries diagnosis were then verified with the results of the histologic examination. The proximal caries sensitivity using digital subtraction radiography was significantly higher than simply examining a single digital radiograph. The sensitivity of the proximal dentinal carious lesion when analyzed with the subtraction radiograph and the radiograph together was higher than with the subtraction radiograph or the radiograph alone. The use of subtraction radiography with contrast media may be useful for detecting proximal dentinal carious lesions.

  2. Digital subtraction cardiopulmonary angiography using FCR (Fuji computed radiography)

    International Nuclear Information System (INIS)

    Tanimura, Shigeo; Tomoyasu, Hiroshi; Banba, Jiro; Masaki, Mikio; Kanno, Yukio; Abe, Kazuo

    1987-01-01

    Digital subtraction cardiopulmonary angiography using FCR was performed on 46 patients including lung cancer, mediastinal tumor, giant bullous formation and others. The images of digital subtraction for pulmonary artery, pulmonary vein and thoracic aorta were studied by comparing to the conventional pulmonary angiogram. Good images of pulmonary artery due to digital subtraction were obtained in 80 % of the 45 cases. This method needed only half volume of contrast media compared to the conventional for obtaining good images and thus reduced side effect. Therefore this method seems to be an usefull pre-operative examination in various chest diseases, especially in case of lung cancer. (author)

  3. Framework for detection and localization of coronary non-calcified plaques in cardiac CTA using mean radial profiles.

    Science.gov (United States)

    Jawaid, Muhammad Moazzam; Riaz, Atif; Rajani, Ronak; Reyes-Aldasoro, Constantino Carlos; Slabaugh, Greg

    2017-10-01

    The high mortality rate associated with coronary heart disease (CHD) has driven intensive research in cardiac imaging and image analysis. The advent of computed tomography angiography (CTA) has turned non-invasive diagnosis of cardiovascular anomalies into reality as calcified coronary plaques can be easily identified due to their high intensity values. However, the detection of non-calcified plaques in CTA is still a challenging problem because of lower intensity values, which are often similar to the nearby blood and muscle tissues. In this work, we propose the use of mean radial profiles for the detection of non-calcified plaques in CTA imagery. Accordingly, we computed radial profiles by averaging the image intensity in concentric rings around the vessel centreline in a first stage. In the subsequent stage, an SVM classifier is applied to identify the abnormal coronary segments. For occluded segments, we further propose a derivative-based method to localize the position and length of the plaque inside the segment. A total of 32 CTA volumes were analysed and a detection accuracy of 88.4% with respect to the manual expert was achieved. The plaque localization accuracy was computed using the Dice similarity coefficient and a mean of 83.2% was achieved. The consistent performance for multi-vendor, multi-institution data demonstrates the reproducibility of our method across different CTA datasets with a good agreement with manual expert annotations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. A novel non-toxic combined CTA1-DD and ISCOMS adjuvant vector for effective mucosal immunization against influenza virus.

    Science.gov (United States)

    Eliasson, Dubravka Grdic; Helgeby, Anja; Schön, Karin; Nygren, Caroline; El-Bakkouri, Karim; Fiers, Walter; Saelens, Xavier; Lövgren, Karin Bengtsson; Nyström, Ida; Lycke, Nils Y

    2011-05-23

    Here we demonstrate that by using non-toxic fractions of saponin combined with CTA1-DD we can achieve a safe and above all highly efficacious mucosal adjuvant vector. We optimized the construction, tested the requirements for function and evaluated proof-of-concept in an influenza A virus challenge model. We demonstrated that the CTA1-3M2e-DD/ISCOMS vector provided 100% protection against mortality and greatly reduced morbidity in the mouse model. The immunogenicity of the vector was superior to other vaccine formulations using the ISCOM or CTA1-DD adjuvants alone. The versatility of the vector was best exemplified by the many options to insert, incorporate or admix vaccine antigens with the vector. Furthermore, the CTA1-3M2e-DD/ISCOMS could be kept 1 year at 4°C or as a freeze-dried powder without affecting immunogenicity or adjuvanticity of the vector. Strong serum IgG and mucosal IgA responses were elicited and CD4 T cell responses were greatly enhanced after intranasal administration of the combined vector. Together these findings hold promise for the combined vector as a mucosal vaccine against influenza virus infections including pandemic influenza. The CTA1-DD/ISCOMS technology represents a breakthrough in mucosal vaccine vector design which successfully combines immunomodulation and targeting in a safe and stable particulate formation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Instrumentation for comparing night sky quality and atmospheric conditions of CTA site candidates

    International Nuclear Information System (INIS)

    Fruck, C.; Schweizer, T.; Häfner, D.; Lorentz, E.; Teshima, M.; Gaug, M.; Ernenwein, J.-P.; Costantini, H.; Mandát, D.; Pech, M.; Bulik, T.; Cieslar, M.; Dominik, M.; Ebr, J.; Garczarczyk, M.; Pareschi, G.; Puerto-Giménez, I.

    2015-01-01

    Many atmospheric and climatic criteria have to be taken into account for the selection of a suitable site for the next generation of imaging air-shower Cherenkov telescopes, the ''Cherenkov Telescope Array'' CTA. Such data are not available with sufficient precision, thus a comparison of the proposed sites and final decision based on a comprehensive characterization is impossible. Identical cross-calibrated instruments have been developed which allow for precise comparison between sites, the cross-validation of existing data, and the ground-validation of satellite data. The site characterization work package of the CTA consortium opted to construct and deploy 9 copies of an autonomous multi-purpose weather sensor, incorporating an infrared cloud sensor, a newly developed sensor for measuring the light of the night sky, and an All-Sky-Camera, the whole referred to as Autonomous Tool for Measuring Observatory Site COnditions PrEcisely (ATMOSCOPE). We present here the hardware that was combined into the ATMOSCOPE and characterize its performance

  6. Model Checking Timed Automata with Priorities using DBM Subtraction

    DEFF Research Database (Denmark)

    David, Alexandre; Larsen, Kim Guldstrand; Pettersson, Paul

    2006-01-01

    In this paper we describe an extension of timed automata with priorities, and efficient algorithms to compute subtraction on DBMs (difference bounded matrices), needed in symbolic model-checking of timed automata with priorities. The subtraction is one of the few operations on DBMs that result...... in a non-convex set needing sets of DBMs for representation. Our subtraction algorithms are efficient in the sense that the number of generated DBMs is significantly reduced compared to a naive algorithm. The overhead in time is compensated by the gain from reducing the number of resulting DBMs since...... this number affects the performance of symbolic model-checking. The uses of the DBM subtraction operation extend beyond timed automata with priorities. It is also useful for allowing guards on transitions with urgent actions, deadlock checking, and timed games....

  7. Increasing Entanglement between Gaussian States by Coherent Photon Subtraction

    DEFF Research Database (Denmark)

    Ourjoumtsev, Alexei; Dantan, Aurelien Romain; Tualle Brouri, Rosa

    2007-01-01

    We experimentally demonstrate that the entanglement between Gaussian entangled states can be increased by non-Gaussian operations. Coherent subtraction of single photons from Gaussian quadrature-entangled light pulses, created by a nondegenerate parametric amplifier, produces delocalized states...

  8. Digital subtraction angiography in patients with central vertigo

    International Nuclear Information System (INIS)

    Inamori, Toru; Takayasu, Yukio; Umetani, Yoshio; Taruoka, Akinori.

    1985-01-01

    Digital subtraction angiography (DSA) is a recently developed non-invasive intravenous angiography which has become possible through real time digital subtraction of x-ray transmission data from an image intensifier and television system. The output signals of the image intensifier-television camera system are digitized by an analog-digital converter. The digital information, 512x512 pixels and 9 bits deep, is fed into the image processing assembly after logarithmic amplification, where 2-8 frames are added and subtracted from mask images for the final digital images. Intravenous digital subtraction angiography was performed in 21 patients with intractable dizzy spells of central origin resistant to treatment. These patients showed some signs of CNS disturbance, although there were no significant findings on CT scans. Surprisingly, findings were abnormal in 14 of 21 patients (66.7%). DSA is, therefore, considered to be an important aid in the diagnosis of vertigo of the central type. (J.P.N.)

  9. Soft-collinear factorization and zero-bin subtractions

    International Nuclear Information System (INIS)

    Chiu Juiyu; Fuhrer, Andreas; Kelley, Randall; Manohar, Aneesh V.; Hoang, Andre H.

    2009-01-01

    We study the Sudakov form factor for a spontaneously broken gauge theory using a (new) Δ-regulator. To be well defined, the effective theory requires zero-bin subtractions for the collinear sectors. The zero-bin subtractions depend on the gauge boson mass M and are not scaleless. They have both finite and 1/ε contributions and are needed to give the correct anomalous dimension and low-scale matching contributions. We also demonstrate the necessity of zero-bin subtractions for soft-collinear factorization. We find that after zero-bin subtractions the form factor is the sum of the collinear contributions minus a soft mass-mode contribution, in agreement with a previous result of Idilbi and Mehen in QCD. This appears to conflict with the method-of-regions approach, where one gets the sum of contributions from different regions.

  10. Digital Subtraction Angiography (DSA) "Road Map": An Angiographic Tool

    Science.gov (United States)

    Turski, P. A.; Stieghorst, M. F.; Strother, C. M.; Crummy, A. B.; Lieberman, R. P.; Mistretta, C. A.

    1982-12-01

    Continuous Digital subtraction combined with intraarterial injections of contrast medium permits the display of arterial structures during real time fluoroscopy. This DSA "road map" facilitates selective catheterization and has proved useful in interventional procedures.

  11. Digital subtraction radiography in the study of moving laryngeal structures

    International Nuclear Information System (INIS)

    Perri, G.; Falaschi, F.; Pieri, L.; Esposito, S.; Ursino, F.

    1988-01-01

    Digital subtraction radiography (DSR) was applied to the study of the larynx in 11 healthy subjects and 15 pathological cases. The method, consisting in the subtraction of images obtained at rest and during phonation or respiratory phases, allowed a clear definition of the normal moving structures - i.e. vocal cords, false cords, pyriform sinuses, thyroid cartilage. Moreover, several pathological conditions could be demonstrated. DSR asserts thus itself as a suitable technique in the functional evaluation of glottis

  12. Decoupling Subtraction Conserving Full Gauge Symmetries : Particles and Fields

    OpenAIRE

    Noriyasu, OHTSUBO; Hideo, MIYATA; Department of Phycics, Kanazawa Technical College; Department of Information Science, Kanazawa Institute of Technolgy

    1984-01-01

    A new subtraction scheme (^^^) which realizes the decoupling and conserves the symmetries of full gauge group simultaneously, is proposed. One particle irreducible Green's functions subtracted by ^^^ reveal the effective low energy symmetries at -p^2≪M^2 and the full symmetries at -p^2≫M^2, where M denotes a heavy mass. Also discussed are conditions in order to carry out ^^^ under two-loop approximation.

  13. AutoDipole - Automated generation of dipole subtraction terms

    International Nuclear Information System (INIS)

    Hasegawa, K.; Uwer, P.

    2009-11-01

    We present an automated generation of the subtraction terms for next-to-leading order QCD calculations in the Catani-Seymour dipole formalism. For a given scattering process with n external particles our Mathematica package generates all dipole terms, allowing for bothmassless and massive dipoles. The numerical evaluation of the subtraction terms proceeds with MadGraph, which provides Fortran code for the necessary scattering amplitudes. Checks of the numerical stability are discussed. (orig.)

  14. Developing a Model to Support Students in Solving Subtraction

    Directory of Open Access Journals (Sweden)

    Nila Mareta Murdiyani

    2013-01-01

    Full Text Available Subtraction has two meanings and each meaning leads to the different strategies. The meaning of “taking away something” suggests a direct subtraction, while the meaning of “determining the difference between two numbers” is more likely to be modeled as indirect addition. Many prior researches found that the second meaning and second strategy rarely appeared in the mathematical textbooks and teacher explanations, including in Indonesia. Therefore, this study was conducted to contribute to the development of a local instruction theory for subtraction by designing instructional activities that can facilitate first grade of primary school students to develop a model in solving two digit numbers subtraction. Consequently, design research was chosen as an appropriate approach for achieving the research aim and Realistic Mathematics Education (RME was used as a guide to design the lesson. This study involved 6 students in the pilot experiment, 31 students in the teaching experiment, and a first grade teacher of SDN 179 Palembang. The  result of this study shows that the beads string could bridge students from the contextual problems (taking ginger candies and making grains bracelets to the use of the empty number line. It also shows that the empty number line could promote students to  use different strategies (direct subtraction, indirect addition, and indirect subtraction in solving subtraction problems. Based on these findings, it is recommended to apply RME in the teaching learning process to make it more meaningful for students. Keywords: Subtraction, Design Research, Realistic Mathematics Education, The Beads String, The Empty Number Line DOI: http://dx.doi.org/10.22342/jme.4.1.567.95-112

  15. Temporal subtraction in chest radiography: Automated assessment of registration accuracy

    International Nuclear Information System (INIS)

    Armato, Samuel G. III; Doshi, Devang J.; Engelmann, Roger; Croteau, Charles L.; MacMahon, Heber

    2006-01-01

    Radiologists routinely compare multiple chest radiographs acquired from the same patient over time to more completely understand changes in anatomy and pathology. While such comparisons are achieved conventionally through a side-by-side display of images, image registration techniques have been developed to combine information from two separate radiographic images through construction of a 'temporal subtraction image'. Although temporal subtraction images provide a powerful mechanism for the enhanced visualization of subtle change, errors in the clinical evaluation of these images may arise from misregistration artifacts that can mimic or obscure pathologic change. We have developed a computerized method for the automated assessment of registration accuracy as demonstrated in temporal subtraction images created from radiographic chest image pairs. The registration accuracy of 150 temporal subtraction images constructed from the computed radiography images of 72 patients was rated manually using a five-point scale ranging from '5-excellent' to '1-poor'; ratings of 3, 4, or 5 reflected clinically acceptable subtraction images, and ratings of 1 or 2 reflected clinically unacceptable images. Gray-level histogram-based features and texture measures are computed at multiple spatial scales within a 'lung mask' region that encompasses both lungs in the temporal subtraction images. A subset of these features is merged through a linear discriminant classifier. With a leave-one-out-by-patient training/testing paradigm, the automated method attained an A z value of 0.92 in distinguishing between temporal subtraction images that demonstrated clinically acceptable and clinically unacceptable registration accuracy. A second linear discriminant classifier yielded an A z value of 0.82 based on a feature subset selected from an independent database of digitized film images. These methods are expected to advance the clinical utility of temporal subtraction images for chest

  16. IR subtraction schemes. Integrating the counterterms at NNLO in QCD

    Energy Technology Data Exchange (ETDEWEB)

    Bolzoni, Paolo; Somogyi, Gabor

    2010-06-15

    We briefly review a subtraction scheme for computing radiative corrections to QCD jet cross sections that can be defined at any order in perturbation theory. Hereafter we discuss the computational methods used to evaluate analytically and numerically the integrated counterterms arising from such a subtraction scheme. Basically these methods the Mellin-Barnes (MB) representations technique together with the harmonic summation and the sector decomposition. (orig.)

  17. IR subtraction schemes. Integrating the counterterms at NNLO in QCD

    International Nuclear Information System (INIS)

    Bolzoni, Paolo; Somogyi, Gabor

    2010-06-01

    We briefly review a subtraction scheme for computing radiative corrections to QCD jet cross sections that can be defined at any order in perturbation theory. Hereafter we discuss the computational methods used to evaluate analytically and numerically the integrated counterterms arising from such a subtraction scheme. Basically these methods the Mellin-Barnes (MB) representations technique together with the harmonic summation and the sector decomposition. (orig.)

  18. AutoDipole - Automated generation of dipole subtraction terms

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, K.; Uwer, P. [Humboldt-Universitaet, Berlin (Germany). Inst. fuer Physik; Moch, S. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany)

    2009-11-15

    We present an automated generation of the subtraction terms for next-to-leading order QCD calculations in the Catani-Seymour dipole formalism. For a given scattering process with n external particles our Mathematica package generates all dipole terms, allowing for bothmassless and massive dipoles. The numerical evaluation of the subtraction terms proceeds with MadGraph, which provides Fortran code for the necessary scattering amplitudes. Checks of the numerical stability are discussed. (orig.)

  19. CTA1-DD adjuvant promotes strong immunity against human immunodeficiency virus type 1 envelope glycoproteins following mucosal immunization.

    Science.gov (United States)

    Sundling, Christopher; Schön, Karin; Mörner, Andreas; Forsell, Mattias N E; Wyatt, Richard T; Thorstensson, Rigmor; Karlsson Hedestam, Gunilla B; Lycke, Nils Y

    2008-12-01

    Strategies to induce potent and broad antibody responses against the human immunodeficiency virus type 1 (HIV-1) envelope glycoproteins (Env) at both systemic and mucosal sites represent a central goal for HIV-1 vaccine development. Here, we show that the non-toxic CTA1-DD adjuvant promoted mucosal and systemic humoral and cell-mediated immune responses following intranasal (i.n.) immunizations with trimeric or monomeric forms of HIV-1 Env in mice and in non-human primates. Env-specific IgG subclasses in the serum of immunized mice reflected a balanced Th1/Th2 type of response. Strikingly, i.n. immunizations with Env and the CTA1-DD adjuvant induced substantial levels of mucosal anti-Env IgA in bronchial alveolar lavage and also detectable levels in vaginal secretions. By contrast, parenteral immunizations of Env formulated in Ribi did not stimulate mucosal IgA responses, while the two adjuvants induced a similar distribution of Env-specific IgG-subclasses in serum. A single parenteral boost with Env in Ribi adjuvant into mice previously primed i.n. with Env and CTA1-DD, augmented the serum anti-Env IgG levels to similar magnitudes as those observed after three intraperitoneal immunizations with Env in Ribi. The augmenting potency of CTA1-DD was similar to that of LTK63 or CpG oligodeoxynucleotides (ODN). However, in contrast to CpG ODN, the effect of CTA1-DD and LTK63 appeared to be independent of MyD88 and toll-like receptor signalling. This is the first demonstration that CTA1-DD augments specific immune responses also in non-human primates, suggesting that this adjuvant could be explored further as a clinically safe mucosal vaccine adjuvant for humoral and cell-mediated immunity against HIV-1 Env.

  20. Advanced Background Subtraction Applied to Aeroacoustic Wind Tunnel Testing

    Science.gov (United States)

    Bahr, Christopher J.; Horne, William C.

    2015-01-01

    An advanced form of background subtraction is presented and applied to aeroacoustic wind tunnel data. A variant of this method has seen use in other fields such as climatology and medical imaging. The technique, based on an eigenvalue decomposition of the background noise cross-spectral matrix, is robust against situations where isolated background auto-spectral levels are measured to be higher than levels of combined source and background signals. It also provides an alternate estimate of the cross-spectrum, which previously might have poor definition for low signal-to-noise ratio measurements. Simulated results indicate similar performance to conventional background subtraction when the subtracted spectra are weaker than the true contaminating background levels. Superior performance is observed when the subtracted spectra are stronger than the true contaminating background levels. Experimental results show limited success in recovering signal behavior for data where conventional background subtraction fails. They also demonstrate the new subtraction technique's ability to maintain a proper coherence relationship in the modified cross-spectral matrix. Beam-forming and de-convolution results indicate the method can successfully separate sources. Results also show a reduced need for the use of diagonal removal in phased array processing, at least for the limited data sets considered.

  1. Digital subtraction angiography for breast diseases

    International Nuclear Information System (INIS)

    Okuyama, Nobuo; Okamoto, Yasushi; Kurita, Minoru; Nonaka, Naomichi; Ozawa, Yoshiyuki; Tsurumi, Kiyohiko

    1986-01-01

    We performed digital subtraction angiography (DSA) via arteries (IA-DSA) and veins (IV-DSA) on 42 patients with breast diseases to investigate its availability. The findings by DSA in cases with breast cancer included: tumor stains, hypervascularity and tortuosity, enlarged blood vessels, encasement and pooling. Metastatic lymph nodes and daughter nodules were also recognized by DSA. In benign tumors of the breast, a tumor stain was observed only in one case of fibroadenoma; otherwise no remarkable changes were noticed. The incidence of signs in cases with breast cancer using IA-DSA was 65 % for hypervascularity, 59 % for tumor stain, 41 % for vascular tortuosity and 41 % for enlargement of vessels. IV-DSA, on the contrary, revealed less incidences. However, tumor stain was seen frequently, and hypervascularity was seldom observed. The number of signs out of the abovementioned six appearing in each case was tabulated. With IA-DSA, there were 5 signs noted in 2 cases, but the majority had fewer: 4 cases in 4 cases and only 2 signs in 4 cases. There were no signs evident in 18 % of the cases. The incidence of the appearance of signs with IV-DSA was lower: there were no signs in 36 % of the cases. Therefore, the diagnostic accuracy of IA-DSA seemed to be fairly good in comparison with that of IV-DSA. The rate of appearance of abnormal signs was also examined, according to the size of the tumors. In IA-DSA, T 1 breast cancers revealed malignant signs in 80 % of the cases, in T 2 there were such signs 75 % and 100 % of the T 3 cases exhibited malignant signs, for an overall average of 82 %. In IV-DSA, T 1 showed 33 %, T 2 showed 70 %, and T 3 , 1 out of 1 case, showed malignant signs, 64 % altogether. It was the bigger the tumor, the larger the number of signs. The smallest breast cancer that exhibited abnormality in DSA was 1.0 x 0.7 cm in size. (J.P.N.)

  2. COLIBRI: partial camera readout and sliding trigger for the Cherenkov Telescope Array CTA

    International Nuclear Information System (INIS)

    Naumann, C L; Tejedor, L A; Martínez, G

    2013-01-01

    Plans for the future Cherenkov telescope array CTA include replacing the monolithic camera designs used in H.E.S.S. and MAGIC-I by one that is built up from a number of identical segments. These so-called clusters will be relatively autonomous, each containing its own triggering and readout hardware. While this choice was made for reasons of flexibility and ease of manufacture and maintenance, such a concept with semi-independent sub-units lends itself quite naturally to the possibility of new, and more flexible, readout modes. In all previously-used concepts, triggering and readout of the camera is centralised, with a single camera trigger per event that starts the readout of all pixels in the camera at the same time and within the same integration time window. The limitations of such a trigger system can reduce the performance of a large array such as CTA, due to the huge amount of useless data created by night-sky background if trigger thresholds are set low enough to achieve the desired 20 GeV energy threshold, and to image losses at high energies due to the rigid readout window. In this study, an alternative concept (''COLIBRI'' = Concept for an Optimised Local Image Building and Readout Infrastructure) is presented, where only those parts of the camera which are likely to actually contain image data (usually a small percentage of the total pixels) are read out. This leads to a significant reduction of the expected data rate and the dead-times incurred in the camera. Furthermore, the quasi-independence of the individual clusters can be used to read different parts of the camera at slightly different times, thus allowing the readout to follow the slow development of the shower image across the camera field of view. This concept of flexible, partial camera readout is presented in the following, together with a description of Monte-Carlo studies performed to evaluate its performance as well as a hardware implementation proposed for CTA.

  3. Comparison of iodine K-edge subtraction and fluorescence subtraction imaging in an animal system

    International Nuclear Information System (INIS)

    Zhang, H.; Zhu, Y.; Bewer, B.; Zhang, L.; Korbas, M.; Pickering, I.J.; George, G.N.; Gupta, M.; Chapman, D.

    2008-01-01

    K-Edge Subtraction (KES) utilizes the discontinuity in the X-ray absorption across the absorption edge of the selected contrast element and creates an image of the projected density of the contrast element from two images acquired just above and below the K-edge of the contrast element. KES has proved to be powerful in coronary angiography, micro-angiography, bronchography, and lymphatic imaging. X-ray fluorescence imaging is a successful technique for the detection of dilute quantities of elements in specimens. However, its application at high X-ray energies (e.g. at the iodine K-edge) is complicated by significant Compton background, which may enter the energy window set for the contrast material's fluorescent X-rays. Inspired by KES, Fluorescence Subtraction Imaging (FSI) is a technique for high-energy (>20 keV) fluorescence imaging using two different incident beam energies just above and below the absorption edge of a contrast element (e.g. iodine). The below-edge image can be assumed as a 'background' image, which includes Compton scatter and fluorescence from other elements. The above-edge image will contain nearly identical spectral content as the below-edge image but will contain the additional fluorescence of the contrast element. This imaging method is especially promising with thick objects with dilute contrast materials, significant Compton background, and/or competing fluorescence lines from other materials. A quality factor is developed to facilitate the comparison. The theoretical value of the quality factor sets the upper limit that an imaging method can achieve when the noise is Poisson limited. The measured value of this factor makes two or more imaging methods comparable. Using the Hard X-ray Micro-Analysis (HXMA) beamline at the Canadian Light Source (CLS), the techniques of FSI and KES were critically compared, with reference to radiation dose, image acquisition time, resolution, signal-to-noise ratios, and quality factor

  4. Impact of imaging quality of change pitch on coronary CTA with 64-detector row CT

    International Nuclear Information System (INIS)

    Li Xiang; Jin Chaolin; Zhang Shutong

    2009-01-01

    Objective: To investigate the impact of imaging quality of pitch on coronary CT angiography (CTA) with 64-detector row CT. Methods: 566 patients were divided into four groups according to heart rate (≤ 50, 51 ∼ 70, 71 ∼ 80 and ≥ 80 bpm). Three dimensional reconstructions were used such as volume rendering (VR), maximum intensity projection(MIP) and curved planar reformation (CPR). Each group was divided into control group and experimential group randomly, using normal pitch and revised pitch respectively, and the imaging quality and influencing factors were analyzed among the four groups. Results: There was significant difference in imaging quality among the four groups (P < 0.05). Each group had difference in imaging quality with normal pitch and revised pitch. Conclusions: The revised pitch helps to improve the imaging quality and meet the demand of diagnosis. (authors)

  5. The CTA Sensitivity to Lorentz-Violating Effects on the Gamma-Ray Horizon

    CERN Document Server

    Fairbairn, Malcolm; Ellis, John; Hinton, Jim; White, Richard

    2014-01-01

    The arrival of TeV-energy photons from distant galaxies is expected to be affected by their QED interaction with intergalactic radiation fields through electron-positron pair production. In theories where high-energy photons violate Lorentz symmetry, the kinematics of the process $\\gamma + \\gamma\\rightarrow e^+ + e^-$ is altered and the cross-section suppressed. Consequently, one would expect more of the highest-energy photons to arrive if QED is modified by Lorentz violation than if it is not. We estimate the sensitivity of Cherenkov Telescope Array (CTA) to changes in the $\\gamma$-ray horizon of the Universe due to Lorentz violation, and find that it should be competitive with other leading constraints.

  6. Efficacy of CTA portography for preoperatively determining the segmental location of focal hepatic lesions

    International Nuclear Information System (INIS)

    Nelson, R.C.; Chemzmar, J.L.; Sugarbaker, P.H.; Bernardino, M.E.

    1989-01-01

    Using cross-sectional images to localize tumors to specific hepatic segments before resection might be difficult because the transverse scissura, an important segmental landmark, is approximately parallel to the axial plane. Since this plane is parallel to the main right and left portal pedicles, the authors postulated that they could localize lesions above this plane to segments 2,4A,7, or 8, and below this plane to segments 3, 4B,5, or 6. The authors have retrospectively evaluated, in a blinded fashion, 24 hepatic masses in 13 patients who underwent CTA-portography and subsequent tumor resection. Using this scheme, they have accurately predicted the primary segmental location in 22 (92%) of 24 surgically confirmed lesions

  7. Atherosclerotic plaque component segmentation in combined carotid MRI and CTA data incorporating class label uncertainty

    DEFF Research Database (Denmark)

    van Engelen, Arna; Niessen, Wiro J.; Klein, Stefan

    2014-01-01

    Atherosclerotic plaque composition can indicate plaque vulnerability. We segment atherosclerotic plaque components from the carotid artery on a combination of in vivo MRI and CT-angiography (CTA) data using supervised voxelwise classification. In contrast to previous studies the ground truth...... for training is directly obtained from 3D registration with histology for fibrous and lipid-rich necrotic tissue, and with [Formula: see text]CT for calcification. This registration does, however, not provide accurate voxelwise correspondence. We therefore evaluate three approaches that incorporate uncertainty......), II) samples are weighted by the local contour distance of the lumen and outer wall between histology and in vivo data, and III) 10% of each class is rejected by Gaussian outlier rejection. Classification was evaluated on the relative volumes (% of tissue type in the vessel wall) for calcified...

  8. X-RAY PULSATIONS FROM THE RADIO-QUIET GAMMA-RAY PULSAR IN CTA 1

    International Nuclear Information System (INIS)

    Caraveo, P. A.; De Luca, A.; Marelli, M.; Bignami, G. F.; Ray, P. S.; Saz Parkinson, P. M.; Kanbach, G.

    2010-01-01

    Prompted by the Fermi-LAT discovery of a radio-quiet gamma-ray pulsar inside the CTA 1 supernova remnant, we obtained a 130 ks XMM-Newton observation to assess the timing behavior of this pulsar. Exploiting both the unprecedented photon harvest and the contemporary Fermi-LAT timing measurements, a 4.7σ single-peak pulsation is detected, making PSR J0007+7303 the second example, after Geminga, of a radio-quiet gamma-ray pulsar also seen to pulsate in X-rays. Phase-resolved spectroscopy shows that the off-pulse portion of the light curve is dominated by a power-law, non-thermal spectrum, while the X-ray peak emission appears to be mainly of thermal origin, probably from a polar cap heated by magnetospheric return currents, pointing to a hot spot varying throughout the pulsar rotation.

  9. Constructive Technology Assessment (CTA) as a tool in coverage with evidence development: the case of the 70-gene prognosis signature for breast cancer diagnostics

    NARCIS (Netherlands)

    Retel, Valesca; Retèl, Valesca P.; Bueno-de-Mesquita, Jolien M.; Hummel, J. Marjan; van de Vijver, Marc J.; Douma, Kirsten F.L.; Karsenberg, Kim; van Dam, Frits S.A.M.; van Krimpen, Cees; Bellot, Frank E.; Roumen, Rudi M.H.; Linn, Sabine C.; van Harten, Willem H.

    2009-01-01

    Objectives: Constructive Technology Assessment (CTA) is a means to guide early implementation of new developments in society, and can be used as an evaluation tool for Coverage with Evidence Development (CED). We used CTA for the introduction of a new diagnostic test in the Netherlands, the 70-gene

  10. Constructive Technology Assessment (CTA) as a tool in Coverage with Evidence Development: The case of the 70-gene prognosis signature for breast cancer diagnostics

    NARCIS (Netherlands)

    Retèl, Valesca P.; Bueno-de-Mesquita, Jolien M.; Hummel, Marjan J. M.; van de Vijver, Marc J.; Douma, Kirsten F. L.; Karsenberg, Kim; van Dam, Frits S. A. M.; van Krimpen, Cees; Bellot, Frank E.; Roumen, Rudi M. H.; Linn, Sabine C.; van Harten, Wim H.

    2009-01-01

    Objectives: Constructive Technology Assessment (CTA) is a means to guide early implementation of new developments in society, and can be used as an evaluation tool for Coverage with Evidence Development (CED). We used CTA for the introduction of a new diagnostic test in the Netherlands, the 70-gene

  11. Hypoattenuation on CTA images with large vessel occlusion: timing affects conspicuity

    Energy Technology Data Exchange (ETDEWEB)

    Dave, Prasham [University of Ottawa, MD Program, Faculty of Medicine, Ottawa, ON (Canada); Lum, Cheemun; Thornhill, Rebecca; Chakraborty, Santanu [University of Ottawa, Department of Radiology, Ottawa, ON (Canada); Ottawa Hospital Research Institute, Ottawa, ON (Canada); Dowlatshahi, Dar [Ottawa Hospital Research Institute, Ottawa, ON (Canada); University of Ottawa, Division of Neurology, Department of Medicine, Ottawa, ON (Canada)

    2017-05-15

    Parenchymal hypoattenuation distal to occlusions on CTA source images (CTASI) is perceived because of the differences in tissue contrast compared to normally perfused tissue. This difference in conspicuity can be measured objectively. We evaluated the effect of contrast timing on the conspicuity of ischemic areas. We collected consecutive patients, retrospectively, between 2012 and 2014 with large vessel occlusions that had dynamic multiphase CT angiography (CTA) and CT perfusion (CTP). We identified areas of low cerebral blood volume on CTP maps and drew the region of interest (ROI) on the corresponding CTASI. A second ROI was placed in an area of normally perfused tissue. We evaluated conspicuity by comparing the absolute and relative change in attenuation between ischemic and normally perfused tissue over seven time points. The median absolute and relative conspicuity was greatest at the peak arterial (8.6 HU (IQR 5.1-13.9); 1.15 (1.09-1.26)), notch (9.4 HU (5.8-14.9); 1.17 (1.10-1.27)), and peak venous phases (7.0 HU (3.1-12.7); 1.13 (1.05-1.23)) compared to other portions of the time-attenuation curve (TAC). There was a significant effect of phase on the TAC for the conspicuity of ischemic vs normally perfused areas (P < 0.00001). The conspicuity of ischemic areas distal to a large artery occlusion in acute stroke is dependent on the phase of contrast arrival with dynamic CTASI and is objectively greatest in the mid-phase of the TAC. (orig.)

  12. DISCOVERY OF TeV GAMMA-RAY EMISSION FROM CTA 1 BY VERITAS

    Energy Technology Data Exchange (ETDEWEB)

    Aliu, E.; Errando, M. [Department of Physics and Astronomy, Barnard College, Columbia University, NY 10027 (United States); Archambault, S. [Physics Department, McGill University, Montreal, QC H3A 2T8 (Canada); Arlen, T. [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095 (United States); Aune, T.; Bouvier, A. [Santa Cruz Institute for Particle Physics and Department of Physics, University of California, Santa Cruz, CA 95064 (United States); Beilicke, M.; Buckley, J. H.; Bugaev, V.; Dickherber, R. [Department of Physics, Washington University, St. Louis, MO 63130 (United States); Benbow, W. [Fred Lawrence Whipple Observatory, Harvard-Smithsonian Center for Astrophysics, Amado, AZ 85645 (United States); Cesarini, A.; Connolly, M. P. [School of Physics, National University of Ireland Galway, University Road, Galway (Ireland); Ciupik, L. [Astronomy Department, Adler Planetarium and Astronomy Museum, Chicago, IL 60605 (United States); Collins-Hughes, E. [School of Physics, University College Dublin, Belfield, Dublin 4 (Ireland); Cui, W. [Department of Physics, Purdue University, West Lafayette, IN 47907 (United States); Duke, C. [Department of Physics, Grinnell College, Grinnell, IA 50112-1690 (United States); Dumm, J. [School of Physics and Astronomy, University of Minnesota, Minneapolis, MN 55455 (United States); Dwarkadas, V. V. [Department of Astronomy and Astrophysics, University of Chicago, Chicago, IL 60637 (United States); Falcone, A., E-mail: muk@astro.columbia.edu, E-mail: smcarthur@ulysses.uchicago.edu [Department of Astronomy and Astrophysics, 525 Davey Lab, Pennsylvania State University, University Park, PA 16802 (United States); and others

    2013-02-10

    We report the discovery of TeV gamma-ray emission coincident with the shell-type radio supernova remnant (SNR) CTA 1 using the VERITAS gamma-ray observatory. The source, VER J0006+729, was detected as a 6.5 standard deviation excess over background and shows an extended morphology, approximated by a two-dimensional Gaussian of semimajor (semiminor) axis 0. Degree-Sign 30 (0. Degree-Sign 24) and a centroid 5' from the Fermi gamma-ray pulsar PSR J0007+7303 and its X-ray pulsar wind nebula (PWN). The photon spectrum is well described by a power-law dN/dE = N {sub 0}(E/3 TeV){sup -{Gamma}}, with a differential spectral index of {Gamma} = 2.2 {+-} 0.2{sub stat} {+-} 0.3{sub sys}, and normalization N {sub 0} = (9.1 {+-} 1.3{sub stat} {+-} 1.7{sub sys}) Multiplication-Sign 10{sup -14} cm{sup -2} s{sup -1} TeV{sup -1}. The integral flux, F {sub {gamma}} = 4.0 Multiplication-Sign 10{sup -12} erg cm{sup -2} s{sup -1} above 1 TeV, corresponds to 0.2% of the pulsar spin-down power at 1.4 kpc. The energetics, colocation with the SNR, and the relatively small extent of the TeV emission strongly argue for the PWN origin of the TeV photons. We consider the origin of the TeV emission in CTA 1.

  13. Bone tumors

    International Nuclear Information System (INIS)

    Unni, K.K.

    1988-01-01

    This book contains the proceedings on bone tumors. Topics covered include: Bone tumor imaging: Contribution of CT and MRI, staging of bone tumors, perind cell tumors of bone, and metastatic bone disease

  14. Comparison of biofouling mechanisms between cellulose triacetate (CTA) and thin-film composite (TFC) polyamide forward osmosis membranes in osmotic membrane bioreactors.

    Science.gov (United States)

    Wang, Xinhua; Zhao, Yanxiao; Yuan, Bo; Wang, Zhiwei; Li, Xiufen; Ren, Yueping

    2016-02-01

    There are two types of popular forward osmosis (FO) membrane materials applied for researches on FO process, cellulose triacetate (CTA) and thin film composite (TFC) polyamide. However, performance and fouling mechanisms of commercial TFC FO membrane in osmotic membrane bioreactors (OMBRs) are still unknown. In current study, its biofouling behaviors in OMBRs were investigated and further compared to the CTA FO membrane. The results indicated that β-D-glucopyranose polysaccharides and microorganisms accounted for approximately 77% of total biovolume on the CTA FO membrane while β-D-glucopyranose polysaccharides (biovolume ratio of 81.1%) were the only dominant biofoulants on the TFC FO membrane. The analyses on the biofouling structure implied that a tighter biofouling layer with a larger biovolume was formed on the CTA FO membrane. The differences in biofouling behaviors including biofoulants composition and biofouling structure between CTA and TFC FO membranes were attributed to different membrane surface properties. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Motion subtraction of the larynx using digital radiography

    International Nuclear Information System (INIS)

    Kumakawa, Kohzoh; Miyakawa, Kouichi

    1990-01-01

    The development of digital radiography (DR) has made it possible to analyze the contour of the laryngeal soft tissue structures in more detail than the conventional screen-film method. The authors first used the DR system for time subtraction of the larynx during inspiration and phonation. The images are acquired by means of frontal tomography of the larynx using the imaging plate during inspiration and phonation separately, and stored into the memory of the DR system. The thickness of the slices is 5.0 mm. Time subtraction between the mask image during inspiration and the live image during phonation is performed using digital processing on CRT. Superimposing the two images at the upper trachea and the thyroid cartilage of the same depth, makes it possible to measure movement of the vocal cord and false vocal cord quantitatively in three dimensions. The authors named this time subtraction as motion subtraction of the larynx. This motion subtraction image can be obtained by on-line digital processing without complicated development technique, but has so high spatial resolution. This image processing seems to be useful in functional radiographic analysis of laryngeal diseases. (author)

  16. Ictal cerebral perfusion patterns in partial epilepsy: SPECT subtraction

    International Nuclear Information System (INIS)

    Lee, Hyang Woon; Hong, Seung Bong; Tae, Woo Suk; Kim, Sang Eun; Seo, Dae Won; Jeong, Seung Cheol; Yi, Ji Young; Hong, Seung Chyul

    2000-01-01

    To investigate the various ictal perfusion patterns and find the relationships between clinical factors and different perfusion patterns. Interictal and ictal SPECT and SPECT subtraction were performed in 61 patients with partial epilepsy. Both positive images showing ictal hyperperfusion and negative images revealing ictal hypoperfusion were obtained by SPECT subtraction. The ictal perfusion patterns of subtracted SPECT were classified into focal hyperperfusion, hyperperfusion-plus, combined hyperperfusion-hypoperfusion, and focal hypoperfusion only. The concordance rates with epileptic focus were 91.8% in combined analysis of ictal hyperperfusion and hypoperfusion images of subtracted SPECT, 85.2% in hyperperfusion images only of subtracted SPECT, and 68.9% in conventional ictal SPECT analysis. Ictal hypoperfusion occurred less frequently in temporal lobe epilepsy (TLE) than extratemporal lobe epilepsy. Mesial temporal hyperperfusion alone was seen only in mesial TLE while lateral temporal hyperperfusion alone was observed only in neocortical TLE. Hippocampal sclerosis had much lower incidence of ictal hypoperfusion than any other pathology. Some patients showed ictal hypoperfusion at epileptic focus with ictal hyperperfusion in the neighboring brain regions where ictal discharges propagated. Hypoperfusion as well as hyperperfusion in ictal SPECT should be considered for localizing epileptic focus. Although the mechanism of ictal hypoperfusion could be an intra-ictal early exhaustion of seizure focus or a steal phenomenon by the propagation of ictal discharges to adjacent brain areas, further study is needed to elucidate it.=20

  17. Ictal cerebral perfusion patterns in partial epilepsy: SPECT subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyang Woon; Hong, Seung Bong; Tae, Woo Suk; Kim, Sang Eun; Seo, Dae Won; Jeong, Seung Cheol; Yi, Ji Young; Hong, Seung Chyul [Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)

    2000-06-01

    To investigate the various ictal perfusion patterns and find the relationships between clinical factors and different perfusion patterns. Interictal and ictal SPECT and SPECT subtraction were performed in 61 patients with partial epilepsy. Both positive images showing ictal hyperperfusion and negative images revealing ictal hypoperfusion were obtained by SPECT subtraction. The ictal perfusion patterns of subtracted SPECT were classified into focal hyperperfusion, hyperperfusion-plus, combined hyperperfusion-hypoperfusion, and focal hypoperfusion only. The concordance rates with epileptic focus were 91.8% in combined analysis of ictal hyperperfusion and hypoperfusion images of subtracted SPECT, 85.2% in hyperperfusion images only of subtracted SPECT, and 68.9% in conventional ictal SPECT analysis. Ictal hypoperfusion occurred less frequently in temporal lobe epilepsy (TLE) than extratemporal lobe epilepsy. Mesial temporal hyperperfusion alone was seen only in mesial TLE while lateral temporal hyperperfusion alone was observed only in neocortical TLE. Hippocampal sclerosis had much lower incidence of ictal hypoperfusion than any other pathology. Some patients showed ictal hypoperfusion at epileptic focus with ictal hyperperfusion in the neighboring brain regions where ictal discharges propagated. Hypoperfusion as well as hyperperfusion in ictal SPECT should be considered for localizing epileptic focus. Although the mechanism of ictal hypoperfusion could be an intra-ictal early exhaustion of seizure focus or a steal phenomenon by the propagation of ictal discharges to adjacent brain areas, further study is needed to elucidate it.

  18. Subtraction and dynamic MR images of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Yoshitaka; Aoki, Manabu; Harada, Junta (Jikei Univ., Tokyo (Japan). School of Medicine)

    1993-04-01

    The purpose of this study was to evaluate the diagnostic effectiveness of subtraction and dynamic MR imaging in patients with breast masses. In 23 breast cancers and six fibroadenomas, spin echo T1 images were obtained at 0.2 Tesla before and every minute after intravenous injection of Gd-DTPA (0.1 or 0.2 mmol/kg). Subtraction images were obtained sequentially on the CRT monitor. All breast masses were enhanced after gadolinium and stood out as bright lesions on subtraction images. The tumor margin and its extension were more precisely evaluated on subtraction MR images than on conventional postcontrast MR images. Breast cancer showed a characteristic time-intensity curve with an early peak, in contrast to fibroadenoma, which showed a gradual increase in signal intensity. Subtraction MR imaging is a simple method for the evaluation of breast masses, and further, the time-intensity curve obtained by dynamic study is helpful in the differential diagnosis of lesions. (author).

  19. Digital subtraction radiographic evaluation of the standardize periapical intraoral radiographs

    International Nuclear Information System (INIS)

    Cho, Bong Hae; Nah, Kyung Soo

    1993-01-01

    The geometrically standardized intraoral radiographs using 5 occlusal registration material were taken serially from immediate, 1 day, 2, 4, 8, 12 and 16 weeks after making the bite blocks. The qualities of those subtracted images were evaluated to check the degree of reproducibility of each impression material. The results were as follows: 1. The standard deviations of the grey scales of the overall subtracted images were 4.9 for Exaflex, 7.2 for Pattern resin, 9.0 for Tooth Shade Acrylic, 12.2 for XCP only, 14.8 for Impregum. 2. The standard deviation of the grey scales of the overall subtracted images were grossly related to those of the localized horizontal line of interest. 3. Exaflex which showed the best subtracted image quality had 15 cases of straight, 14 cases of wave, 1 case of canyon shape. Impregum which showed the worst subtracted image quality had 4 cases of straight, 8 cases of wave, 18 cases of canyon shape respectively.

  20. Hexadecyltrimethylammonium bromide (CTA-Br) and 1-butyl-3-methylimidazolium tetrafluoroborate (bmim-BF4) in aqueous solution: An ephemeral binary system.

    Science.gov (United States)

    Comelles, Francesc; Ribosa, Isabel; Gonzalez, Juan José; Garcia, M Teresa

    2017-03-15

    Mixtures of the cationic surfactant hexadecyltrimethylammonium bromide (CTA-Br) and the ionic liquid 1-butyl-3-methylimidazolium tetrafluoroborate (bmim-BF 4 ) in aqueous solutions are expected to behave as typical binary cationic surfactant system taking into account the surface activity displayed by the ionic liquid, instead of considering the IL as a water cosolvent. Surface tension and conductivity measurements have been conducted as a function of the total concentration of the mixtures at different surfactant mole fraction (α CTA-Br ) to investigate the surface active properties. Turbidity immediately appearing when the compounds are mixed in water suggests the spontaneous formation of the low soluble compound hexadecyltrimethylammonium tetrafluoroborate (CTA-BF 4 ), together with the salt formed by the respective counterions bmim + and Br - in solution. For α CTA-Br ≠0.5, furthermore of the mentioned compounds, the spare bmim-BF 4 (for α CTA-Br Br (for α CTA-Br >0.5), are also present in the aqueous solution. Systems containing excess of bmim-BF 4 show a low critical aggregate concentration (cac), but an unexpected high surface tension at cac (γ cac ≈53-56mN/m), as pure CTA-BF 4 . For systems containing excess of CTA-Br, cac increases but γ cac decreases up to 36mN/m. Mixtures of pure CTA-BF 4 and bmim-BF 4 or CTA-Br behave as typical binary surfactant systems. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Diagnostic accuracy of CTA and MRI/MRA in the evaluation of the cortical venous reflux in the intracranial dural arteriovenous fistula DAVF

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Yen-Heng [National Taiwan University, Department of Medical Imaging and Radiology, Hospital and Medical College, Taipei (China); National Taiwan University Hospital, Department of Medical Imaging, Douliu City (China); Wang, Yu-Fen; Lee, Chung-Wei; Chen, Ya-Fang [National Taiwan University, Department of Medical Imaging and Radiology, Hospital and Medical College, Taipei (China); Liu, Hon-Man [National Taiwan University, Department of Medical Imaging and Radiology, Hospital and Medical College, Taipei (China); Fu Jen Catholic University, Department of Medical Imaging and Radiology, Hospital and Medical College, New Taipei City (China); Fu Jen Catholic University Hospital, Department of Medical Imaging, New Taipei City (China); Hsieh, Hong-Jen [National Taiwan University Hospital, Department of Medical Imaging, Douliu City (China)

    2018-01-15

    Computed tomography angiography (CTA) and magnetic resonance imaging/angiography (MRI/MRA) are used for the diagnosis of intracranial dural arteriovenous fistulas (DAVFs). The purpose of this study was to compare the diagnostic accuracy of CTA and magnetic resonance imaging/angiography (MRI/MRA) for detection of cortical venous reflux (CVR) in intracranial DAVFs. The records of patients with angiography-confirmed intracranial DAVFs who also received CTA and MRI/MRA from January 2008 to July 2016 were reviewed. CTA and MRI/MRA were reviewed for signs of CVR, and the diagnostic accuracy of individual signs was evaluated by receiver operating curve (ROC) analysis. A total 108 patients were included in this study. CTA signs of CVR included abnormal dilatation, early enhancement, and the presence of a medullary or pial vein. MRI/MRA signs of CVR included abnormal dilatation, early enhancement, flow-related enhancement, flow void, and medullary or pial venous collaterals. The sensitivity of individual CTA signs ranged from 62 to 96%, and specificities from 79 to 94%. The sensitivities of individual MRI/MRA signs ranged from 58 to 83%, and specificities from 77 to 93%. The area under ROC curve (AUC) of CTA and MRI/MRA were 0.91 and 0.87, respectively (P = 0.04 in direct comparison). In subgroup analysis, CTA had better diagnostic accuracy for higher grade disease (P = 0.05) and non-aggressive manifestation (P = 0.04). Both CTA and MRI/MRA have good diagnostic accuracy for detection of CVR in patients with intracranial DAVFs. There is modest evidence that CTA is better than MRI/MRA. (orig.)

  2. Dissociation between peripheral blood chimerism and tolerance to hindlimb composite tissue transplants: preferential localization of chimerism in donor bone.

    Science.gov (United States)

    Rahhal, Dina N; Xu, Hong; Huang, Wei-Chao; Wu, Shengli; Wen, Yujie; Huang, Yiming; Ildstad, Suzanne T

    2009-09-27

    Mixed chimerism induces donor-specific tolerance to composite tissue allotransplants (CTAs). In the present studies, we used a nonmyeloablative conditioning approach to establish chimerism and promote CTA acceptance. Wistar Furth (RT1A(u)) rats were conditioned with 600 to 300 cGy total body irradiation (TBI, day-1), and 100 x 10(6) T-cell-depleted ACI (RT1A(abl)) bone marrow cells were transplanted on day 0, followed by a 11-day course of tacrolimus and one dose of antilymphocyte serum (day 10). Heterotopic osteomyocutaneous flap transplantation was performed 4 to 6 weeks after bone marrow transplantation. Mixed chimerism was initially achieved in almost all recipients, but long-term acceptance of CTA was only achieved in rats treated with 600 cGy TBI. When anti-alphabeta-T-cell receptor (TCR) monoclonal antibody (mAb) (day-3) was added into the regimens, donor chimerism was similar to recipients preconditioned without anti-alphabeta-TCR mAb. However, the long-term CTA survival was significantly improved in chimeras receiving more than or equal to 300 cGy TBI plus anti-alphabeta-TCR mAb. Higher levels of donor chimerism were associated with CTA acceptance. The majority of flap acceptors lost peripheral blood chimerism within 6 months. However, donor chimerism persisted in the transplanted bone at significantly higher levels compared with other hematopoietic compartments. The compartment donor chimerism may be responsible for the maintenance of tolerance to CTA. Long-term acceptors were tolerant to a donor skin graft challenge even in the absence of peripheral blood chimerism. Mixed chimerism established by nonmyeloablative conditioning induces long-term acceptance of CTA, which is associated with persistent chimerism preferentially in the transplanted donor bone.

  3. K-edge subtraction synchrotron X-ray imaging in bio-medical research.

    Science.gov (United States)

    Thomlinson, W; Elleaume, H; Porra, L; Suortti, P

    2018-05-01

    High contrast in X-ray medical imaging, while maintaining acceptable radiation dose levels to the patient, has long been a goal. One of the most promising methods is that of K-edge subtraction imaging. This technique, first advanced as long ago as 1953 by B. Jacobson, uses the large difference in the absorption coefficient of elements at energies above and below the K-edge. Two images, one taken above the edge and one below the edge, are subtracted leaving, ideally, only the image of the distribution of the target element. This paper reviews the development of the KES techniques and technology as applied to bio-medical imaging from the early low-power tube sources of X-rays to the latest high-power synchrotron sources. Applications to coronary angiography, functional lung imaging and bone growth are highlighted. A vision of possible imaging with new compact sources is presented. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  4. ECG-gating in non-cardiac digital subtraction angiography

    International Nuclear Information System (INIS)

    Gattoni, F.; Baldini, V.; Cairo, F.

    1987-01-01

    This paper reports the results of the ECG-gating in non-cardiac digital subtraction angiography (DSA). One hundred and fifteen patients underwent DSA (126 examinations); ECG-gating was applied in 66/126 examinations: images recorded at 70% of R wave were subtracted. Artifacts produced by vascular movements were evaluated in all patients: only 40 examinations, carried out whithout ECG-gating, showed vascular artifacts. The major advantage of the ECG-gated DSA is the more efficent subtraction because of the better images superimposition: therefore, ECG-gating can be clinically helpful. On the contrary, it could be a problem in arrhytmic or bradycardic patients. ECG-gating is helpful in DSA imaging of the thoracic and abdominal aorta and of the cervical and renal arteries. In the examinations of peripheral vessels of the limbs it is not so efficent as in the trunk or in the neck

  5. A study of transverse image reconstruction with digital subtraction angiography

    International Nuclear Information System (INIS)

    Sakamoto, Kiyoshi; Kotoura, Noriko; Terasawa, Yuuji; Oda, Masahiko; Gotou, Hiroshi; Nasada, Toshiya; Tanooka, Masao

    1995-01-01

    For digital subtraction angiography (DSA) with C-type equipment, it is possible to radiate an X-ray during rotation and to collect data at different angular settings. We tried to reconstruct transverse image from data obtained by scanning DSA images at different angular settings. 88 projection data were obtained by rotating the object at 180deg during radiation. Reconstruction was made using the convolution method with pixel value distribution for each projection. Similarly, the image quality of the reconstructed images were compared with the unsubtracted and subtracted ones. In case a part object was outside the calculating region, artifacts were generally produced. However, the artifacts were reduced by subtracting the background from the image. In addition, the cupping phenomenon caused by beam hardening was relaxed and high-quality imaging could be achieved. This method will become even more effective, if we will use it with selective angiography in which the limited area is enhanced. (author)

  6. Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Ewen, K.

    1986-01-01

    The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and careful caudal shielding of the field are advocated. (orig.)

  7. Intravenous digital subtraction angiography of transplanted kidney artery

    International Nuclear Information System (INIS)

    Tessier, J.P; Teyssou, H.; Verdier, J.P.; Tison, E.; Meyblum, J.; Marchal, M.

    1986-01-01

    Results of 351 intravenous digital subtraction angiographs (AN) of transplanted kidneys emphasized reliability of this examination for detection of renal artery stenosis. A prospective study of 219 patients (188 interpretable AN) showed significant stenosis of grafted artery in 22% of cases: 17% of the 126 patients with normal blood pressure and 34% of the 62 cases of hypertension. Digital subtraction allows, with a single injection, assessment of renal artery, nephrogram and excretory cavities, but it is not a substitute for conventional intravenous urography 1 to 2 months after grafting [fr

  8. On a gauge invariant subtraction scheme for massive quantum electrodynamics

    International Nuclear Information System (INIS)

    Abdalla, E.; Gomes, M.; Koeberle, R.

    A momentum-space subtraction scheme for massive quantum electrodynamics is proposed which respects gauge invariance, in contrast to ordinary normal product techniques. As a consequence the dependence of Green functions on the ghost mass becomes very simple and formally gauge invariant normal products of degree up to four, when subtracted according to the proposed scheme, are automatically gauge invariant. As an aplication we discuss the proof of the Adler-Bardeen theorem. Zero mass limits can be taken for Green function after the integration over intermediate states has been carried out [pt

  9. Digital subtraction arthrography of the hips and of the shoulders

    International Nuclear Information System (INIS)

    Fink, B.K.; Schedel, J.; Fink, U.; Hansen, M.; Hilbertz, T.; Hagena, F.W.

    1991-01-01

    In a study on 60 patients, it could be shown that very good results can be achieved in the region of the shoulder joint with the use of the digital subtraction technique and of digital image intensifier radiography. A further possibility of using the digital subtraction technique for proving endoprosthesis loosenings of the hip demonstrated its importance after a short time and has become a routine method in the meantime. These two examination techniques are displayed methodologically and their clinical possibilities of use are assessed in this contribution. (orig.)

  10. Power corrections in the N-jettiness subtraction scheme

    Energy Technology Data Exchange (ETDEWEB)

    Boughezal, Radja [High Energy Physics Division, Argonne National Laboratory,Argonne, IL 60439 (United States); Liu, Xiaohui [Department of Physics, Beijing Normal University,Beijing, 100875 (China); Center of Advanced Quantum Studies, Beijing Normal University,Beijing, 100875 (China); Center for High-Energy Physics, Peking University,Beijing, 100871 (China); Maryland Center for Fundamental Physics, University of Maryland,College Park, MD 20742 (United States); Petriello, Frank [Department of Physics & Astronomy, Northwestern University,Evanston, IL 60208 (United States); High Energy Physics Division, Argonne National Laboratory,Argonne, IL 60439 (United States)

    2017-03-30

    We discuss the leading-logarithmic power corrections in the N-jettiness subtraction scheme for higher-order perturbative QCD calculations. We compute the next-to-leading order power corrections for an arbitrary N-jet process, and we explicitly calculate the power correction through next-to-next-to-leading order for color-singlet production for both qq̄ and gg initiated processes. Our results are compact and simple to implement numerically. Including the leading power correction in the N-jettiness subtraction scheme substantially improves its numerical efficiency. We discuss what features of our techniques extend to processes containing final-state jets.

  11. Optimization of pulverised coal combustion by means of CFD/CTA modeling

    Directory of Open Access Journals (Sweden)

    Filkoski Risto V.

    2006-01-01

    Full Text Available The objective of the work presented in this paper was to apply a method for handling two-phase reacting flow for prediction of pulverized coal combustion in large-scale boiler furnace and to assess the ability of the model to predict existing power plant data. The paper presents the principal steps and results of the numerical modeling of power boiler furnace with tangential disposition of the burners. The computational fluid dynamics/computational thermal analysis (CFD/CTA approach is utilized for creation of a three-dimensional model of the boiler furnace, including the platen superheater in the upper part of the furnace. Standard k-e model is employed for description of the turbulent flow. Coal combustion is modeled by the mixture fraction/probability density function approach for the reaction chemistry, with equilibrium assumption applied for description of the system chemistry. Radiation heat transfer is computed by means of the simplified P-N model, based on the expansion of the radiation intensity into an orthogonal series of spherical harmonics. Some distinctive results regarding the examined boiler performance in capacity range between 65 and 95% are presented graphically. Comparing the simulation predictions and available site measurements concerning temperature, heat flux and combustion efficiency, a conclusion can be drawn that the model produces realistic insight into the furnace processes. Qualitative agreement indicates reasonability of the calculations and validates the employed sub-models. After the validation and verification of the model it was used to check the combustion efficiency as a function of coal dust sieve characteristics, as well as the impact of burners modification with introduction of over fire air ports to the appearance of incomplete combustion, including CO concentration, as well as to the NOx concentration. The described case and other experiences with CFD/CTA stress the advantages of numerical modeling and

  12. TH-AB-207A-03: Skin Dose to Patients Receiving Multiple CTA and CT Exams of the Head

    International Nuclear Information System (INIS)

    Nawfel, RD; Young, G

    2016-01-01

    Purpose: To measure patient skin dose from CT angiography (CTA) and CT exams of the head, and determine if patients having multiple exams could receive cumulative doses that approach or exceed deterministic thresholds. Methods: This study was HIPAA compliant and conducted with IRB approval. Patient skin doses were measured over a 4 month period using nanoDot OSL dosimeters placed on the head of 52 patients for two CT scanners. On each scanner, 26 patients received CT exams (scanner 1: 10 females, 16 males, mean age 64.2 years; scanner 2: 18 females, 8 males, mean age 61.2 years). CT exam dose metrics, CTDIvol and dose-length product (DLP) were recorded for each exam. Additionally, skin dose was measured on an acrylic skull phantom in each scanner and on a neuro-interventional imaging system using clinical protocols. Measured dose data was used to estimate peak skin dose (PSD) for 4 patients receiving multiple exams including CTA, head CT, and cerebral angiography. Results: For scanner 1, the mean PSD for CTA exams (98.9 ± 5.3 mGy) and for routine head CT exams (39.2 ± 3.7 mGy) agreed reasonably well with the PSD measured on the phantom, 105.4 mGy and 40.0 mGy, respectively. Similarly for scanner 2, the mean PSD for CTA exams (98.8 ± 7.4 mGy) and for routine head CT exams (42.9 ± 9.4 mGy) compared well with phantom measurements, 95.2 mGy and 37.6 mGy, respectively. In addition, the mean PSD was comparable between scanners for corresponding patient exams, CTA and routine head CT respectively. PSD estimates ranged from 1.9 – 4.5 Gy among 4 patients receiving multiple exams. Conclusion: Patients having several exams including both CTA and routine head CT may receive cumulative doses approaching or exceeding the threshold for single dose deterministic effects.

  13. TH-AB-207A-03: Skin Dose to Patients Receiving Multiple CTA and CT Exams of the Head

    Energy Technology Data Exchange (ETDEWEB)

    Nawfel, RD; Young, G [Brigham & Women’s Hospital, Boston, MA (United States)

    2016-06-15

    Purpose: To measure patient skin dose from CT angiography (CTA) and CT exams of the head, and determine if patients having multiple exams could receive cumulative doses that approach or exceed deterministic thresholds. Methods: This study was HIPAA compliant and conducted with IRB approval. Patient skin doses were measured over a 4 month period using nanoDot OSL dosimeters placed on the head of 52 patients for two CT scanners. On each scanner, 26 patients received CT exams (scanner 1: 10 females, 16 males, mean age 64.2 years; scanner 2: 18 females, 8 males, mean age 61.2 years). CT exam dose metrics, CTDIvol and dose-length product (DLP) were recorded for each exam. Additionally, skin dose was measured on an acrylic skull phantom in each scanner and on a neuro-interventional imaging system using clinical protocols. Measured dose data was used to estimate peak skin dose (PSD) for 4 patients receiving multiple exams including CTA, head CT, and cerebral angiography. Results: For scanner 1, the mean PSD for CTA exams (98.9 ± 5.3 mGy) and for routine head CT exams (39.2 ± 3.7 mGy) agreed reasonably well with the PSD measured on the phantom, 105.4 mGy and 40.0 mGy, respectively. Similarly for scanner 2, the mean PSD for CTA exams (98.8 ± 7.4 mGy) and for routine head CT exams (42.9 ± 9.4 mGy) compared well with phantom measurements, 95.2 mGy and 37.6 mGy, respectively. In addition, the mean PSD was comparable between scanners for corresponding patient exams, CTA and routine head CT respectively. PSD estimates ranged from 1.9 – 4.5 Gy among 4 patients receiving multiple exams. Conclusion: Patients having several exams including both CTA and routine head CT may receive cumulative doses approaching or exceeding the threshold for single dose deterministic effects.

  14. Digital subtraction radiography in the study of the lacrimal system

    International Nuclear Information System (INIS)

    Falaschi, F.; Pieri, L.; Perri, G.; Signorini, G.; Genovese Ebert, F.

    1988-01-01

    The authors emphasize the usefulness of digital dacrycystography (DCG), as compared with various current technoques. Utilizing a radiographic unit equipped with a video-fluoroscopic system and interfaced to a digital video-processor, several digitalized images are acquired before, during and after the injection of contrast medium. Final images are obtained by subtraction of suitable pairs of source frames. Twenty-six patients affected by epiphora have been examined so far. In 21 cases digital subtraction DCG allowed an accurate visualization of the lacrimal system; in the other five patients the amount of information was acceptable. This methodology allows the assessment of both the normal anatomy of the lacrimal passages and their pathological patterns, such as obstructions, stenoses, fistulas, chronic dacrycystites, lacrimal stones. The examination is easy and quick to perform, with no discomfort for the patient. Digital subtraction DCG proves thus to be a very valuable technique thanks to its possible electronic elaboration - i.e. the subtraction and the magnification of images - to its better contrast resolution, and to the possibility it yields of dynamic studies under radioscopic control

  15. Use of digital subtraction angiography for renal transplant evaluation

    International Nuclear Information System (INIS)

    Fanucci, E.; Orlacchio, A.; Pocek, M.; Svegliati, F.

    1986-01-01

    Intravenous digital subtraction angiography (IVDSA) was used to evaluate 6 renal allograft recipients and 3 potential renal donors. In 4 potential renal donors and in 2 allograft recipients, angiographic data were confirmed by surgery. IVDSA is a safe, accurate, easily performed, outpatient procedure; in our opinion DSA should became the procedure of choice to study vascular anatomy in renal transplant evaluation

  16. Summation and subtraction using a modified autoshaping procedure in pigeons.

    Science.gov (United States)

    Ploog, Bertram O

    2008-06-01

    A modified autoshaping paradigm (significantly different from those previously reported in the summation literature) was employed to allow for the simultaneous assessment of stimulus summation and subtraction in pigeons. The response requirements and the probability of food delivery were adjusted such that towards the end of training 12 of 48 trials ended in food delivery, the same proportion as under testing. Stimuli (outlines of squares of three sizes and colors: A, B, and C) were used that could be presented separately or in any combination of two or three stimuli. Twelve of the pigeons (summation groups) were trained with either A, B, and C or with AB, BC, and CA, and tested with ABC. The remaining 12 pigeons (subtraction groups) received training with ABC but were tested with A, B, and C or with AB, BC, and CA. These groups were further subdivided according to whether stimulus elements were presented either in a concentric or dispersed manner. Summation did not occur; subtraction occurred in the two concentric groups. For interpretation of the results, configural theory, the Rescorla-Wagner model, and the composite-stimulus control model were considered. The results suggest different mechanisms responsible for summation and subtraction.

  17. Digital subtraction angiography in the diagnosis of Fallot's tetralogy

    International Nuclear Information System (INIS)

    Ivanitskij, A.V.; Tereshkin, Ya.A.; Sobolev, A.V.; Stolyar, V.L.; Slyunyastikov, M.A.

    1995-01-01

    The authors analyze the efficacy of digital subtraction angiography (DSA) in the diagnosis of Fallot's tetralogy (FT); this method helps simplity and cut down their scope of investigations but does not deteriorate their informative value. DSA findings in 120 patients with TF are analyzed. 5 refs.; 6 figs

  18. Novel Ratio Subtraction and Isoabsorptive Point Methods for ...

    African Journals Online (AJOL)

    Purpose: To develop and validate two innovative spectrophotometric methods used for the simultaneous determination of ambroxol hydrochloride and doxycycline in their binary mixture. Methods: Ratio subtraction and isoabsorptive point methods were used for the simultaneous determination of ambroxol hydrochloride ...

  19. Determination of the kalium-subtracted total beta in food

    International Nuclear Information System (INIS)

    Liu Guofan

    1985-01-01

    A procedure for measuring the kalium-subtracted total beta in food can be applied to estimating the contamination of beta nuclides except 40 K. The procedure, calculating formula, and some experiences in practice are described in this paper. The method is simple, rapid, and very useful to food contamination monitoring

  20. Enriching Addition and Subtraction Fact Mastery through Games

    Science.gov (United States)

    Bay-Williams, Jennifer M.; Kling, Gina

    2014-01-01

    The learning of "basic facts"--single-digit combinations for addition, subtraction, multiplication, and division--has long been a focus of elementary school mathematics. Many people remember completing endless worksheets, timed tests, and flash card drills as they attempted to "master" their basic facts as children. However,…

  1. Dual-energy subtraction radiography of the breast

    International Nuclear Information System (INIS)

    Asaga, Taro; Masuzawa, Chihiro; Kawahara, Satoru; Motohashi, Hisahiko; Okamoto, Takashi; Tamura, Nobuo

    1988-01-01

    Dual-energy projection radiography was applied to breast examination. To perform the dual-energy subtraction radiography using a digital radiography unit, high and low-energy exposures were made at an appropriate time interval under differing X-ray exposure conditions. Dual-energy subtraction radiography was performed in 41 cancer patients in whom the tumor shadow was equivocal or the border of cancer infiltration was not clearly demonstrated by compression mammography, and 15 patients with benign diseases such as fibrocystic disease, cyst and fibroadenoma. In 21 cases out of the 41 cancer patients, the dual-energy subtraction radiography clearly visualized the malignant tumor shadows and the border of cancer infiltration and the daughter nodules by removing the shadows of normal mammary gland. On the other hand, beign diseases such as fibrocystic disease and cyst could be diagnosed as such, because the tumor shadow and the irregularly concentrated image of mammary gland disappeared by the dual-energy subtraction. These results suggest that this new technique will be useful in examination of breast masses. (author)

  2. Dual-energy subtraction radiography of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Asaga, Taro; Masuzawa, Chihiro; Kawahara, Satoru; Motohashi, Hisahiko; Okamoto, Takashi; Tamura, Nobuo

    1988-06-01

    Dual-energy projection radiography was applied to breast examination. To perform the dual-energy subtraction radiography using a digital radiography unit, high and low-energy exposures were made at an appropriate time interval under differing X-ray exposure conditions. Dual-energy subtraction radiography was performed in 41 cancer patients in whom the tumor shadow was equivocal or the border of cancer infiltration was not clearly demonstrated by compression mammography, and 15 patients with benign diseases such as fibrocystic disease, cyst and fibroadenoma. In 21 cases out of the 41 cancer patients, the dual-energy subtraction radiography clearly visualized the malignant tumor shadows and the border of cancer infiltration and the daughter nodules by removing the shadows of normal mammary gland. On the other hand, beign diseases such as fibrocystic disease and cyst could be diagnosed as such, because the tumor shadow and the irregularly concentrated image of mammary gland disappeared by the dual-energy subtraction. These results suggest that this new technique will be useful in examination of breast masses.

  3. Digital subtraction angiography (DSA) of the heart and coronary arteries

    International Nuclear Information System (INIS)

    Struyven, J.J.; Delcour, C.; Brion, J.P.; Vandenbosch, G.; Claessens, J.

    1986-01-01

    Digital subtraction angiography has potential advantages over conventional radiography. The removal of background structures makes possible to visualize chambers of the heart, great vessels and coronary arteries with a lower iodine signal than with conventional cineangiography. Digital data used for imaging can been manipulated for assessment and quantitation of the ventricular fonction and the coronary circulation

  4. New electronic filtering technique in digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Stacul, F; Pozzi-Mucelli, R; Predonzan, F; Magnaldi, S; Godina, G

    1986-01-01

    The authors report their experience with a new electronic filtering technique in digital subtraction angiography (DSA). The principles of the technique are reported and the advantages in comparison with conventional filters are stressed (accurate and fast placement without fluoroscopic exposure). The system provided excellent results in about 900 DSA examinations.

  5. Children's Understanding of the Addition/Subtraction Complement Principle

    Science.gov (United States)

    Torbeyns, Joke; Peters, Greet; De Smedt, Bert; Ghesquière, Pol; Verschaffel, Lieven

    2016-01-01

    Background: In the last decades, children's understanding of mathematical principles has become an important research topic. Different from the commutativity and inversion principles, only few studies have focused on children's understanding of the addition/subtraction complement principle (if a - b = c, then c + b = a), mainly relying on verbal…

  6. N-jettiness Subtractions for NNLO QCD calculations

    International Nuclear Information System (INIS)

    Gaunt, Jonathan R.; Stahlhofen, Maximilian; Tackmann, Frank J.; Walsh, Jonathan R.; California Univ., CA

    2015-05-01

    We present a subtraction method utilizing the N-jettiness observable, Τ N , to perform QCD calculations for arbitrary processes at next-to-next-to-leading order (NNLO). Our method employs soft-collinear effective theory (SCET) to determine the IR singular contributions of N-jet cross sections for Τ N → 0, and uses these to construct suitable Τ N -subtractions. The construction is systematic and economic, due to being based on a physical observable. The resulting NNLO calculation is fully differential and in a form directly suitable for combining with resummation and parton showers. We explain in detail the application to processes with an arbitrary number of massless partons at lepton and hadron colliders together with the required external inputs in the form of QCD amplitudes and lower-order calculations. We provide explicit expressions for the Τ N -subtractions at NLO and NNLO. The required ingredients are fully known at NLO, and at NNLO for processes with two external QCD partons. The remaining NNLO ingredient for three or more external partons can be obtained numerically with existing NNLO techniques. As an example, we employ our method to obtain the NNLO rapidity spectrum for Drell-Yan and gluon-fusion Higgs production. We discuss aspects of numerical accuracy and convergence and the practical implementation. We also discuss and comment on possible extensions, such as more-differential subtractions, necessary steps for going to N 3 LO, and the treatment of massive quarks.

  7. Imaging and Variability Studies of CTA 102 during the 2016 January γ-ray Flare

    Science.gov (United States)

    Li, Xiaofeng; Mohan, P.; An, T.; Hong, Xiaoyu; Cheng, Xiaopeng; Yang, Jun; Zhang, Yingkang; Zhang, Zhongli; Zhao, Wei

    2018-02-01

    The γ-ray-bright blazar CTA 102 is studied using imaging (new 15 GHz and archival 43 GHz Very Long Baseline Array, VLBA data) and time variable optical flux density, polarization degree, and electric vector position angle (EVPA) spanning between 2015 June 1 and 2016 October 1, covering a prominent γ-ray flare during 2016 January. The pc-scale jet indicates expansion with oscillatory features up to 17 mas. Component proper motions are in the range 0.04–0.33 mas yr‑1 with acceleration up to 1.2 mas followed by a slowing down beyond 1.5 mas. A jet bulk Lorentz factor ≥17.5, position angle of 128.°3, inclination angle ≤6.°6 and intrinsic half opening angle ≤1.°8 are derived from the VLBA data. These inferences are employed in a helical jet model to infer long-term variability in flux density, polarization degree, EVPA, and a rotation of the Stokes Q and U parameters. A core distance of r core,43 GHz = 22.9 pc, and a magnetic field strength at 1 pc and the core location of 1.57 G and 0.07 G, respectively, are inferred using the core-shift method. The study is useful in the context of estimating jet parameters and in offering clues to distinguish mechanisms responsible for variability over different timescales.

  8. CTA-A project for a new generation of Cherenkov telescopes

    International Nuclear Information System (INIS)

    Doro, Michele

    2011-01-01

    Gamma-rays provide a powerful insight into the non-thermal universe and perhaps a unique probe for new physics beyond the standard model. Current experiments are already giving results in the physics of acceleration of cosmic rays in supernova remnants, pulsar and active galactic nuclei with a 100 sources detected at very-high-energies so far. Despite its relatively recent appearance, very high-energy gamma-ray astronomy has proven to have reached a mature technology with fast assembling, relatively cheap and reliable telescopes. The goal of future installation is to increase the sensitivity by a factor 10 compared to current installations, and enlarge the energy domain from few 10s of GeV to a 100 TeV. Gamma-ray spectra of astrophysical origin are rather soft thus hardly one single size telescope can cover more than 1.5 decades in energy, therefore an array of telescopes of 2-3 different sizes is required. Hereafter, we present design considerations for a Cherenkov Telescope Array (CTA), a project for a new generation of highly automated telescopes for gamma-ray astronomy. The status of the project, technical solutions and an insight in the involved physics will be presented.

  9. The clinical usefulness evaluation of normal saline injection in coronary artery computed tomography angiography (Coronary CTA)

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kang Kyo; Lee, Mi Hwa; Cho, Pyong Kon [Dept. of Radiological Science, Catholic University of Daegu, Daegu (Korea, Republic of)

    2014-12-15

    The purpose of this study is that in coronary artery angiography computed tomography (coronary CTA), to gain high quality of image and to use low dose radiation by administrating normal saline and converting the mode of scanning heart rate (HR) characteristics before infusing contrast media. All patients data (total specimens: 200, male: 108, female: 92) were measured by using appropriate mode of scanning the heart rate (HR) after injection of saline. in addition we measured radiation dose (CTDIvol, effective dose) in all examinations. CT number and noise, and blurring of coronary artery (proximal RCA, middle RCA, proximal LCA) were measured and compared. The result of this study after injection of saline, mean heart rate was decreased about 4.8±0.3 bpm (beats per minute). 33 patients (13%) got converting scan mode due to reducing heart rate (HR). In prospective gating mode, radiation dose were measured less 6.0±1.0 mSv (54.1%) than retrospective gating mode. Also showed a significant difference in heart rate decrease in image evaluation.

  10. Dark matter signals from Draco and Willman 1: prospects for MAGIC II and CTA

    Science.gov (United States)

    Bringmann, Torsten; Doro, Michele; Fornasa, Mattia

    2009-01-01

    The next generation of ground-based Imaging Air Cherenkov Telescopes will play an important role in indirect dark matter searches. In this article, we consider two particularly promising candidate sources for dark matter annihilation signals, the nearby dwarf galaxies Draco and Willman 1, and study the prospects of detecting such a signal for the soon-operating MAGIC II telescope system as well as for the planned installation of CTA, taking special care of describing the experimental features that affect the detectional prospects. For the first time in such studies, we fully take into account the effect of internal bremsstrahlung, which has recently been shown to considerably enhance, in some cases, the gamma-ray flux in the high energies domain where Atmospheric Cherenkov Telescopes operate, thus leading to significantly harder annihilation spectra than traditionally considered. While the detection of the spectral features introduced by internal bremsstrahlung would constitute a smoking gun signature for dark matter annihilation, we find that for most models the overall flux still remains at a level that will be challenging to detect, unless one adopts somewhat favorable descriptions of the smooth dark matter distribution in the dwarfs.

  11. The clinical usefulness evaluation of normal saline injection in coronary artery computed tomography angiography (Coronary CTA)

    International Nuclear Information System (INIS)

    Jung, Kang Kyo; Lee, Mi Hwa; Cho, Pyong Kon

    2014-01-01

    The purpose of this study is that in coronary artery angiography computed tomography (coronary CTA), to gain high quality of image and to use low dose radiation by administrating normal saline and converting the mode of scanning heart rate (HR) characteristics before infusing contrast media. All patients data (total specimens: 200, male: 108, female: 92) were measured by using appropriate mode of scanning the heart rate (HR) after injection of saline. in addition we measured radiation dose (CTDIvol, effective dose) in all examinations. CT number and noise, and blurring of coronary artery (proximal RCA, middle RCA, proximal LCA) were measured and compared. The result of this study after injection of saline, mean heart rate was decreased about 4.8±0.3 bpm (beats per minute). 33 patients (13%) got converting scan mode due to reducing heart rate (HR). In prospective gating mode, radiation dose were measured less 6.0±1.0 mSv (54.1%) than retrospective gating mode. Also showed a significant difference in heart rate decrease in image evaluation

  12. A method for dynamic subtraction MR imaging of the liver

    Directory of Open Access Journals (Sweden)

    Setti Ernesto

    2006-06-01

    Full Text Available Abstract Background Subtraction of Dynamic Contrast-Enhanced 3D Magnetic Resonance (DCE-MR volumes can result in images that depict and accurately characterize a variety of liver lesions. However, the diagnostic utility of subtraction images depends on the extent of co-registration between non-enhanced and enhanced volumes. Movement of liver structures during acquisition must be corrected prior to subtraction. Currently available methods are computer intensive. We report a new method for the dynamic subtraction of MR liver images that does not require excessive computer time. Methods Nineteen consecutive patients (median age 45 years; range 37–67 were evaluated by VIBE T1-weighted sequences (TR 5.2 ms, TE 2.6 ms, flip angle 20°, slice thickness 1.5 mm acquired before and 45s after contrast injection. Acquisition parameters were optimized for best portal system enhancement. Pre and post-contrast liver volumes were realigned using our 3D registration method which combines: (a rigid 3D translation using maximization of normalized mutual information (NMI, and (b fast 2D non-rigid registration which employs a complex discrete wavelet transform algorithm to maximize pixel phase correlation and perform multiresolution analysis. Registration performance was assessed quantitatively by NMI. Results The new registration procedure was able to realign liver structures in all 19 patients. NMI increased by about 8% after rigid registration (native vs. rigid registration 0.073 ± 0.031 vs. 0.078 ± 0.031, n.s., paired t-test and by a further 23% (0.096 ± 0.035 vs. 0.078 ± 0.031, p t-test after non-rigid realignment. The overall average NMI increase was 31%. Conclusion This new method for realigning dynamic contrast-enhanced 3D MR volumes of liver leads to subtraction images that enhance diagnostic possibilities for liver lesions.

  13. Appearance of the canine meninges in subtraction magnetic resonance images.

    Science.gov (United States)

    Lamb, Christopher R; Lam, Richard; Keenihan, Erin K; Frean, Stephen

    2014-01-01

    The canine meninges are not visible as discrete structures in noncontrast magnetic resonance (MR) images, and are incompletely visualized in T1-weighted, postgadolinium images, reportedly appearing as short, thin curvilinear segments with minimal enhancement. Subtraction imaging facilitates detection of enhancement of tissues, hence may increase the conspicuity of meninges. The aim of the present study was to describe qualitatively the appearance of canine meninges in subtraction MR images obtained using a dynamic technique. Images were reviewed of 10 consecutive dogs that had dynamic pre- and postgadolinium T1W imaging of the brain that was interpreted as normal, and had normal cerebrospinal fluid. Image-anatomic correlation was facilitated by dissection and histologic examination of two canine cadavers. Meningeal enhancement was relatively inconspicuous in postgadolinium T1-weighted images, but was clearly visible in subtraction images of all dogs. Enhancement was visible as faint, small-rounded foci compatible with vessels seen end on within the sulci, a series of larger rounded foci compatible with vessels of variable caliber on the dorsal aspect of the cerebral cortex, and a continuous thin zone of moderate enhancement around the brain. Superimposition of color-encoded subtraction images on pregadolinium T1- and T2-weighted images facilitated localization of the origin of enhancement, which appeared to be predominantly dural, with relatively few leptomeningeal structures visible. Dynamic subtraction MR imaging should be considered for inclusion in clinical brain MR protocols because of the possibility that its use may increase sensitivity for lesions affecting the meninges. © 2014 American College of Veterinary Radiology.

  14. Fully automatic detection and segmentation of abdominal aortic thrombus in post-operative CTA images using Deep Convolutional Neural Networks.

    Science.gov (United States)

    López-Linares, Karen; Aranjuelo, Nerea; Kabongo, Luis; Maclair, Gregory; Lete, Nerea; Ceresa, Mario; García-Familiar, Ainhoa; Macía, Iván; González Ballester, Miguel A

    2018-05-01

    Computerized Tomography Angiography (CTA) based follow-up of Abdominal Aortic Aneurysms (AAA) treated with Endovascular Aneurysm Repair (EVAR) is essential to evaluate the progress of the patient and detect complications. In this context, accurate quantification of post-operative thrombus volume is required. However, a proper evaluation is hindered by the lack of automatic, robust and reproducible thrombus segmentation algorithms. We propose a new fully automatic approach based on Deep Convolutional Neural Networks (DCNN) for robust and reproducible thrombus region of interest detection and subsequent fine thrombus segmentation. The DetecNet detection network is adapted to perform region of interest extraction from a complete CTA and a new segmentation network architecture, based on Fully Convolutional Networks and a Holistically-Nested Edge Detection Network, is presented. These networks are trained, validated and tested in 13 post-operative CTA volumes of different patients using a 4-fold cross-validation approach to provide more robustness to the results. Our pipeline achieves a Dice score of more than 82% for post-operative thrombus segmentation and provides a mean relative volume difference between ground truth and automatic segmentation that lays within the experienced human observer variance without the need of human intervention in most common cases. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Reducing radiation dose without compromising image quality in preoperative perforator flap imaging with CTA using ASIR technology.

    Science.gov (United States)

    Niumsawatt, Vachara; Debrotwir, Andrew N; Rozen, Warren Matthew

    2014-01-01

    Computed tomographic angiography (CTA) has become a mainstay in preoperative perforator flap planning in the modern era of reconstructive surgery. However, the increased use of CTA does raise the concern of radiation exposure to patients. Several techniques have been developed to decrease radiation dosage without compromising image quality, with varying results. The most recent advance is in the improvement of image reconstruction using an adaptive statistical iterative reconstruction (ASIR) algorithm. We sought to evaluate the image quality of ASIR in preoperative deep inferior epigastric perforator (DIEP) flap surgery, through a direct comparison with conventional filtered back projection (FBP) images. A prospective review of 60 consecutive ASIR and 60 consecutive FBP CTA images using similar protocol (except for radiation dosage) was undertaken, analyzed by 2 independent reviewers. In both groups, we were able to accurately identify axial arteries and their perforators. Subjective analysis of image quality demonstrated no statistically significant difference between techniques. ASIR can thus be used for preoperative imaging with similar image quality to FBP, but with a 60% reduction in radiation delivery to patients.

  16. Some characteristics of protons emitted in backward hemisphere in dTa and CTa interactions at Psub(0)=4.2 GeV/c

    International Nuclear Information System (INIS)

    Gasparyan, A.P.; Mekhtiev, R.R.

    1985-01-01

    In interactions of deuterium and carbon relativistic nuclei with tantalum at P 0 =4.2 GeV/c for secondary protons with 100 deg emission angle in lab. system, the temperature of proton kinetic energy spectra in three angle intervals has been determined. It does not contradict the values obtained in hadron-nuclear interactions. The slope parameters for backward emitted proton spectra over comulative variable β=/E-psub(11) msub(p) in dTa and CTa collisions and hadron-nucleus interactions are approximately equal as well. At the same time some difference of s: ope parameters on kinetic energy and cumulative variables spectra between dTa and CTa is observed. In CTa collisions the spectra are deeper. The comparison with the predictions of cascade model for CTa interactions is made. The cascade model taking into account the final state interaction of nucleons on the whole satisfactorily describes the experimental data

  17. Design concepts for the Cherenkov Telescope Array CTA: an advanced facility for ground-based high-energy gamma-ray astronomy

    International Nuclear Information System (INIS)

    Allekotte, I.; Arnaldi, H.; Asorey, H.; Gomez Berisso, M.; Sofo Haro, M.; Cillis, A.; Rovero, A.C.; Supanitsky, A.D.; Actis, M.; Antico, F.; Bottani, A.; Ochoa, I.; Ringegni, P.; Vallejo, G.; De La Vega, G.; Etchegoyen, A.; Videla, M.; Gonzalez, F.; Pallota, J.; Quel, E.; Ristori, P.; Romero, G.E.; Suarez, A.; Papyan, G.; Pogosyan, L.; Sahakian, V.; Bissaldi, E.; Egberts, K.; Reimer, A.; Reimer, O.; Shellard, R.C.; Santos, E.M.; De Gouveia Dal Pino, E.M.; Kowal, G.; De Souza, V.; Todero Peixoto, C.J.; Maneva, G.; Temnikov, P.; Vankov, H.; Golev, V.; Ovcharov, E.; Bonev, T.; Dimitrov, D.; Hrupec, D.; Nedbal, D.; Rob, L.; Sillanpaa, A.; Takalo, L.; Beckmann, V.; Benallou, M.; Boutonnet, C.; Corlier, M.; Courty, B.; Djannati-Atai, A.; Dufour, C.; Gabici, S.; Guglielmi, L.; Olivetto, C.; Pita, S.; Punch, M.; Selmane, S.; Terrier, R.; Yoffo, B.; Brun, P.; Carton, P.H.; Cazaux, S.; Corpace, O.; Delagnes, E.; Disset, G.; Durand, D.; Glicenstein, J.F.; Guilloux, F.; Kosack, K.; Medina, C.; Micolon, P.; Mirabel, F.; Moulin, E.; Peyaud, B.; Reymond, J.M.; Veyssiere, C.

    2011-01-01

    Ground-based gamma-ray astronomy has had a major breakthrough with the impressive results obtained using systems of imaging atmospheric Cherenkov telescopes. Ground-based gamma-ray astronomy has a huge potential in astrophysics, particle physics and cosmology. CTA is an international initiative to build the next generation instrument, with a factor of 5-10 improvement in sensitivity in the 100 GeV-10 TeV range and the extension to energies well below 100 GeV and above 100 TeV. CTA will consist of two arrays (one in the north, one in the south) for full sky coverage and will be operated as open observatory. The design of CTA is based on currently available technology. This document reports on the status and presents the major design concepts of CTA. (authors)

  18. An innovative telescope control system architecture for SST-GATE telescopes at the CTA Observatory

    Science.gov (United States)

    Fasola, Gilles; Mignot, Shan; Laporte, Philippe; Abchiche, Abdel; Buchholtz, Gilles; Jégouzo, Isabelle

    2014-07-01

    SST-GATE (Small Size Telescope - GAmma-ray Telescope Elements) is a 4-metre telescope designed as a prototype for the Small Size Telescopes (SST) of the Cherenkov Telescope Array (CTA), a major facility for the very high energy gamma-ray astronomy of the next three decades. In this 100-telescope array there will be 70 SSTs, involving a design with an industrial view aiming at long-term service, low maintenance effort and reduced costs. More than a prototype, SST-GATE is also a fully functional telescope that shall be usable by scientists and students at the Observatoire de Meudon for 30 years. The Telescope Control System (TCS) is designed to work either as an element of a large array driven by an array controller or in a stand-alone mode with a remote workstation. Hence it is built to be autonomous with versatile interfacing; as an example, pointing and tracking —the main functions of the telescope— are managed onboard, including astronomical transformations, geometrical transformations (e.g. telescope bending model) and drive control. The core hardware is a CompactRIO (cRIO) featuring a real-time operating system and an FPGA. In this paper, we present an overview of the current status of the TCS. We especially focus on three items: the pointing computation implemented in the FPGA of the cRIO —using CORDIC algorithms— since it enables an optimisation of the hardware resources; data flow management based on OPCUA with its specific implementation on the cRIO; and the use of an EtherCAT field-bus for its ability to provide real-time data exchanges with the sensors and actuators distributed throughout the telescope.

  19. Carotid artery stenosis: Performance of advanced vessel analysis software in evaluating CTA

    International Nuclear Information System (INIS)

    Tsiflikas, Ilias; Biermann, Christina; Thomas, Christoph; Ketelsen, Dominik; Claussen, Claus D.; Heuschmid, Martin

    2012-01-01

    Objectives: The aim of this study was to evaluate time efficiency and diagnostic reproducibility of an advanced vessel analysis software for diagnosis of carotid artery stenosis. Material and methods: 40 patients with suspected carotid artery stenosis received head and neck DE-CTA as part of their pre-interventional workup. Acquired data were evaluated by 2 independent radiologists. Stenosis grading was performed by MPR eyeballing with freely adjustable MPRs and with a preliminary prototype of the meanwhile available client-server and advanced visualization software syngo.via CT Vascular (Siemens Healthcare, Erlangen, Germany). Stenoses were graded according to the following 5 categories: I: 0%, II: 1–50%, III: 51–69%, IV: 70–99% and V: total occlusion. Furthermore, time to diagnosis for each carotid artery was recorded. Results: Both readers achieved very good specificity values and good respectively very good sensitivity values without significant differences between both reading methods. Furthermore, there was a very good correlation between both readers for both reading methods without significant differences (kappa value: standard image interpretation k = 0.809; advanced vessel analysis software k = 0.863). Using advanced vessel analysis software resulted in a significant time saving (p < 0.0001) for both readers. Time to diagnosis could be decreased by approximately 55%. Conclusions: Advanced vessel analysis application CT Vascular of the new imaging software syngo.via (Siemens Healthcare, Forchheim, Germany) provides a high rate of reproducibility in assessment of carotid artery stenosis. Furthermore a significant time saving in comparison to standard image interpretation is achievable

  20. Carotid artery stenosis: Performance of advanced vessel analysis software in evaluating CTA

    Energy Technology Data Exchange (ETDEWEB)

    Tsiflikas, Ilias, E-mail: ilias.tsiflikas@med.uni-tuebingen.de [University Hospital of Tuebingen, Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany); Biermann, Christina, E-mail: christina.biermann@siemens.com [University Hospital of Tuebingen, Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany); Siemens AG, Siemens Healthcare Consulting, Allee am Röthelheimpark 3A, 91052 Erlangen (Germany); Thomas, Christoph, E-mail: christoph.thomas@med.uni-tuebingen.de [University Hospital of Tuebingen, Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany); Ketelsen, Dominik, E-mail: dominik.ketelsen@med.uni-tuebingen.de [University Hospital of Tuebingen, Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany); Claussen, Claus D., E-mail: claus.claussen@med.uni-tuebingen.de [University Hospital of Tuebingen, Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany); Heuschmid, Martin, E-mail: martin.heuschmid@med.uni-tuebingen.de [University Hospital of Tuebingen, Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)

    2012-09-15

    Objectives: The aim of this study was to evaluate time efficiency and diagnostic reproducibility of an advanced vessel analysis software for diagnosis of carotid artery stenosis. Material and methods: 40 patients with suspected carotid artery stenosis received head and neck DE-CTA as part of their pre-interventional workup. Acquired data were evaluated by 2 independent radiologists. Stenosis grading was performed by MPR eyeballing with freely adjustable MPRs and with a preliminary prototype of the meanwhile available client-server and advanced visualization software syngo.via CT Vascular (Siemens Healthcare, Erlangen, Germany). Stenoses were graded according to the following 5 categories: I: 0%, II: 1–50%, III: 51–69%, IV: 70–99% and V: total occlusion. Furthermore, time to diagnosis for each carotid artery was recorded. Results: Both readers achieved very good specificity values and good respectively very good sensitivity values without significant differences between both reading methods. Furthermore, there was a very good correlation between both readers for both reading methods without significant differences (kappa value: standard image interpretation k = 0.809; advanced vessel analysis software k = 0.863). Using advanced vessel analysis software resulted in a significant time saving (p < 0.0001) for both readers. Time to diagnosis could be decreased by approximately 55%. Conclusions: Advanced vessel analysis application CT Vascular of the new imaging software syngo.via (Siemens Healthcare, Forchheim, Germany) provides a high rate of reproducibility in assessment of carotid artery stenosis. Furthermore a significant time saving in comparison to standard image interpretation is achievable.

  1. El gobierno corporativo en la cooperativa de trabajo asociado Recuperar CTA

    Directory of Open Access Journals (Sweden)

    Carlos Mario Toro Orozco

    2012-01-01

    Full Text Available En la cooperativa de trabajo asociado Recuperar (CTA se ha logrado demostrar, a través de esta investigación, la efectividad de la concertación entre el gobierno corporativo y la vinculación de los asociados a la solución eficaz y eficiente de un problema social prioritario para una ciudad, como ha sido el reciclaje de las basuras. Es por ello que en este artículo se evidencia cómo, a partir del Gobierno Corporativo , esta organización ha logrado una proyección económica y social que le ha permitido cumplir las necesidades de los asociados, estableciendo una cultura gerencial y de resultados, por medio de lo cual se ha logrado la permanencia de dicha organización en el sector solidario, como un ejemplo de gestión y proyección social. La metodología utilizada es un estudio de corte cualitativo a partir del análisis de los diferentes aspectos para establecer los mecanismos de Gobierno Corporativo. Los resultados permiten observar que su crecimiento y permanencia en el tiempo se ha obtenido, a través de la coherencia con los valores cooperativos, la igualdad y la solidaridad con las exigencias del mercado; la participación y el control democrático; de igual forma la identidad, autonomía e independencia por parte de sus asociados.

  2. Deblurring in digital tomosynthesis by iterative self-layer subtraction

    Science.gov (United States)

    Youn, Hanbean; Kim, Jee Young; Jang, SunYoung; Cho, Min Kook; Cho, Seungryong; Kim, Ho Kyung

    2010-04-01

    Recent developments in large-area flat-panel detectors have made tomosynthesis technology revisited in multiplanar xray imaging. However, the typical shift-and-add (SAA) or backprojection reconstruction method is notably claimed by a lack of sharpness in the reconstructed images because of blur artifact which is the superposition of objects which are out of planes. In this study, we have devised an intuitive simple method to reduce the blur artifact based on an iterative approach. This method repeats a forward and backward projection procedure to determine the blur artifact affecting on the plane-of-interest (POI), and then subtracts it from the POI. The proposed method does not include any Fourierdomain operations hence excluding the Fourier-domain-originated artifacts. We describe the concept of the self-layer subtractive tomosynthesis and demonstrate its performance with numerical simulation and experiments. Comparative analysis with the conventional methods, such as the SAA and filtered backprojection methods, is addressed.

  3. Evaluation of the pulmonary vascular bed by digital subtraction angiography

    International Nuclear Information System (INIS)

    Shikuwa, Masahiro; Asai, Sadahiro; Hara, Shiro; Yamasa, Toshihiko; Miyahara, Yoshiyuki; Hara, Kohei; Nishijima, Kyoji.

    1995-01-01

    We studied the usefulness of digital subtraction angiography for evaluating the pulmonary capillary bed. Four individuals underwent the procedure. One was a healthy volunteer and the others were patients with chronic pulmonary emphysema. During catheterization, an 8 F balloon catheter was manipulated into the right pulmonary artery. A total of 20 ml of contrast material was injected at a rate of 10 ml/sec at full inspiration. In the normal subject, the capillary bed filled homogeneously and no defect was seen. In the patients, the pulmonary artery was nearly normal, but severe defects were observed in the pulmonary capillaries. Contrast resolvability was greater with digital subtraction pulmonary angiography than with pulmonary perfusion scintigraphy or pulmonary arteriography. This technique makes possible the visual evaluation of the pulmonary capillary bed. (author)

  4. Subtraction imaging of the ECG gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Tanegashima, K.; Fukui, M.; Hyodo, H.

    1987-05-01

    The subtracting manipulation of contrast-enhanced gated cardiac CT (GCCT) images was experimentally studied with TCT 60A - 30 type (Toshiba) for clinical use, thereby reducing the amount of contrast medium (CM). Initially the optimum relationship between the concentration of CM and its injected velocity was determined using the model of resected canine hearts and in actual dogs. The emphasized good-subtracted images were obtained when the difference of CT values was approximately 40 H.U. between cardiac cavity and myocardium. Such condition was feasible in the use of 25 % Diatrizoic acid and its injected velocity of 0.02 ml/kg/sec. Finally the reduction of the amount of CM by 1/3 became possible in clinical settings. The method is applicable to multi-slice GCCT in various heart diseases.

  5. Momentum-subtraction renormalization techniques in curved space-time

    Energy Technology Data Exchange (ETDEWEB)

    Foda, O.

    1987-10-01

    Momentum-subtraction techniques, specifically BPHZ and Zimmermann's Normal Product algorithm, are introduced as useful tools in the study of quantum field theories in the presence of background fields. In a model of a self-interacting massive scalar field, conformally coupled to a general asymptotically-flat curved space-time with a trivial topology, momentum-subtractions are shown to respect invariance under general coordinate transformations. As an illustration, general expressions for the trace anomalies are derived, and checked by explicit evaluation of the purely gravitational contributions in the free field theory limit. Furthermore, the trace of the renormalized energy-momentum tensor is shown to vanish at the Gell-Mann Low eigenvalue as it should.

  6. Momentum-subtraction renormalization techniques in curved space-time

    International Nuclear Information System (INIS)

    Foda, O.

    1987-01-01

    Momentum-subtraction techniques, specifically BPHZ and Zimmermann's Normal Product algorithm, are introduced as useful tools in the study of quantum field theories in the presence of background fields. In a model of a self-interacting massive scalar field, conformally coupled to a general asymptotically-flat curved space-time with a trivial topology, momentum-subtractions are shown to respect invariance under general coordinate transformations. As an illustration, general expressions for the trace anomalies are derived, and checked by explicit evaluation of the purely gravitational contributions in the free field theory limit. Furthermore, the trace of the renormalized energy-momentum tensor is shown to vanish at the Gell-Mann Low eigenvalue as it should

  7. Digital subtraction angiography in the assessment of cardiovascular disease

    International Nuclear Information System (INIS)

    Harrington, D.P.; Boxt, L.M.

    1985-01-01

    Digital subtraction angiography (DSA) is a new radiographic method for evaluating the cardiovascular system. It represents another in a continuing series of computer-assisted diagnostic imaging modalities. The advantages of this technique are its relatively noninvasive nature combined with diagnostically acceptable angiographic images of a variety of cardiovascular structures. Major clinical applications of DSA include its use in imaging of localized regions of peripheral arterial disease and as a screening procedure in evaluating extracranial carotid and vertebral artery disease and renovascular hypertension. Cardiac applications of DSA include assessment of ventricular function, recognition and quantification of intracardiac shunts, visualization of coronary artery bypass grafts, and the study of complex congenital cardiac malformations. Digital subtraction angiography may also be used to evaluate intracranial aneurysms and vascular tumors

  8. Multivariate spatial condition mapping using subtractive fuzzy cluster means.

    Science.gov (United States)

    Sabit, Hakilo; Al-Anbuky, Adnan

    2014-10-13

    Wireless sensor networks are usually deployed for monitoring given physical phenomena taking place in a specific space and over a specific duration of time. The spatio-temporal distribution of these phenomena often correlates to certain physical events. To appropriately characterise these events-phenomena relationships over a given space for a given time frame, we require continuous monitoring of the conditions. WSNs are perfectly suited for these tasks, due to their inherent robustness. This paper presents a subtractive fuzzy cluster means algorithm and its application in data stream mining for wireless sensor systems over a cloud-computing-like architecture, which we call sensor cloud data stream mining. Benchmarking on standard mining algorithms, the k-means and the FCM algorithms, we have demonstrated that the subtractive fuzzy cluster means model can perform high quality distributed data stream mining tasks comparable to centralised data stream mining.

  9. Hybrid intravenous digital subtraction angiography of the carotid bifurcation

    International Nuclear Information System (INIS)

    Burbank, F.H.; Enzmann, D.; Keyes, G.S.; Brody, W.R.

    1984-01-01

    A hybrid digital subtraction angiography technique and noise-reduction algorithm were used to evaluate the carotid bifurcation. Temporal, hybrid, and reduced-noise hybrid images were obtained in right and left anterior oblique projections, and both single- and multiple-frame images were created with each method. The resulting images were graded on a scale of 1 to 5 by three experienced neuroradiologists. Temporal images were preferred over hybrid images. The percentage of nondiagnostic examinations, as agreed upon by two readers, was higher for temporal alone than temporal + hybrid. In addition, also by agreement between two readers, temporal + hybrid images significantly increased the number of bifurcations seen in two views (87%) compared to temporal subtraction alone

  10. Practical applications and methods in performing cardiac digital subtraction angiography

    International Nuclear Information System (INIS)

    Markovic, D.M.; Withrow, S.; Moodie, D.S.

    1986-01-01

    One of the purposes of this book is to outline the utility of digital subtraction angiography (DSA) in common clinical practice. No text has dealt with the actual physical setup of the room or the patient prior and during a digital subtraction angiographic study at rest and with exercise. This chapter outlines the steps commonly used when cardiac DSA is performed on patients in the authors' laboratory. The authors have learned over the last few years the best way to prepare the patient and the equipment and it is hoped that utilizing this experience, other centers may avoid the mistakes the authors have made in the past and develop new techniques for the future

  11. Introduction to the principles of Digital Subtraction Angiography (DSA)

    International Nuclear Information System (INIS)

    Kaplanis, P.

    1997-01-01

    Medical applications of advanced technology have rapidly become more sophisticated and more widespread. The field of diagnostic imaging is by no means an exception. There has been a number of breathtaking developments in the field of medical imaging in recent years. Today higher quality, greater clarity and more minute precision are considered not advantages but necessities. Hence new developments are concentrated in the data acquisition and image processing based on the microprocessor controlled modules interfaced with state of the art radiological imaging equipment. One such development is the subtraction of x-rays vis a computer for better visualization of blood vessels, cavities of the heart and of the coronary and pulmonary vascular system. This procedure is termed Digital Subtraction Angiography (DSA). (author)

  12. Spinal pedicle subtraction osteotomy for fixed sagittal imbalance patients

    Science.gov (United States)

    Hyun, Seung-Jae; Kim, Yongjung J; Rhim, Seung-Chul

    2013-01-01

    In addressing spinal sagittal imbalance through a posterior approach, the surgeon now may choose from among a variety of osteotomy techniques. Posterior column osteotomies such as the facetectomy or Ponte or Smith-Petersen osteotomy provide the least correction, but can be used at multiple levels with minimal blood loss and a lower operative risk. Pedicle subtraction osteotomies provide nearly 3 times the per-level correction of Ponte/Smith-Petersen osteotomies; however, they carry increased technical demands, longer operative time, and greater blood loss and associated significant morbidity, including neurological injury. The literature focusing on pedicle subtraction osteotomy for fixed sagittal imbalance patients is reviewed. The long-term overall outcomes, surgical tips to reduce the complications and suggestions for their proper application are also provided. PMID:24340276

  13. Introduction to the principles of Digital Subtraction Angiography (DSA)

    Energy Technology Data Exchange (ETDEWEB)

    Kaplanis, P [Medical Physics Department, Nicosia General Hospital, Nicosia (Cyprus)

    1998-12-31

    Medical applications of advanced technology have rapidly become more sophisticated and more widespread. The field of diagnostic imaging is by no means an exception. There has been a number of breathtaking developments in the field of medical imaging in recent years. Today higher quality, greater clarity and more minute precision are considered not advantages but necessities. Hence new developments are concentrated in the data acquisition and image processing based on the microprocessor controlled modules interfaced with state of the art radiological imaging equipment. One such development is the subtraction of x-rays vis a computer for better visualization of blood vessels, cavities of the heart and of the coronary and pulmonary vascular system. This procedure is termed Digital Subtraction Angiography (DSA). (author). 5 refs, 3 figs.

  14. Self-mixing differential vibrometer based on electronic channel subtraction

    International Nuclear Information System (INIS)

    Donati, Silvano; Norgia, Michele; Giuliani, Guido

    2006-01-01

    An instrument for noncontact measurement of differential vibrations is developed, based on the self-mixing interferometer. As no reference arm is available in the self-mixing configuration, the differential mode is obtained by electronic subtraction of signals from two (nominally equal) vibrometer channels, taking advantage that channels are servo stabilized and thus insensitive to speckle and other sources of amplitude fluctuation. We show that electronic subtraction is nearly as effective as field superposition. Common-mode suppression is 25-30 dB, the dynamic range (amplitude) is in excess of 100 μm, and the minimum measurable (differential) amplitude is 20 nm on aB=10 kHz bandwidth. The instrument has been used to measure vibrations of two metal samples kept in contact, revealing the hysteresis cycle in the microslip and gross-slip regimes, which are of interest in the study of friction induced vibration damping of gas turbine blades for aircraft applications

  15. Digital subtraction angiography in pediatric cerebrovascular occlusive disease

    International Nuclear Information System (INIS)

    Faerber, E.N.; Griska, L.A.B.; Swartz, J.D.; Capitanio, M.A.; Popky, G.L.

    1984-01-01

    While conventional angiography has been used to demonstrate cerebrovascular occlusive disease in the past, digital subtraction angiography (DSA) is capable of showing progressive vascular involvement with ease, simplicity, and extremely low morbidity, making it particularly well suited for children and outpatients either alone or coordinated with computed tomography. The authors discuss the usefulness and advantages of DSA as demonstrated in 7 infants and children with hemiplegia, 4 of whom had sickle-cell disease

  16. Intravenous digital subtraction angiography investigation of reversible cerebral ischemia

    International Nuclear Information System (INIS)

    Pistolesi, G.F.; Maso, R.; Filosto, L.; Piovan, E.; Morgante, D.; Taddei, G.; Tonegutti, M.; Portuese, A.

    1986-01-01

    The brachio-cephalic, carotid, vertebral and intra-cranial vessels of 497 patients presenting reversible ischemic attacks (R.I.A) were evaluated with venous digital subtraction angiography (V.D.S.A.). Alterations of the vascular wall were observed in 289/497 (58.2%) patients, of whom 60% presented multiple locations (539 lesions): obstruction (12%), stenosis >50% (29%), stenosis 50%. The incidence of vascular lesions was higher (p [fr

  17. Temporal subtraction of chest radiographs compensating pose differences

    Science.gov (United States)

    von Berg, Jens; Dworzak, Jalda; Klinder, Tobias; Manke, Dirk; Kreth, Adrian; Lamecker, Hans; Zachow, Stefan; Lorenz, Cristian

    2011-03-01

    Temporal subtraction techniques using 2D image registration improve the detectability of interval changes from chest radiographs. Although such methods are well known for some time they are not widely used in radiologic practice. The reason is the occurrence of strong pose differences between two acquisitions with a time interval of months to years in between. Such strong perspective differences occur in a reasonable number of cases. They cannot be compensated by available image registration methods and thus mask interval changes to be undetectable. In this paper a method is proposed to estimate a 3D pose difference by the adaptation of a 3D rib cage model to both projections. The difference between both is then compensated for, thus producing a subtraction image with virtually no change in pose. The method generally assumes that no 3D image data is available from the patient. The accuracy of pose estimation is validated with chest phantom images acquired under controlled geometric conditions. A subtle interval change simulated by a piece of plastic foam attached to the phantom becomes visible in subtraction images generated with this technique even at strong angular pose differences like an anterior-posterior inclination of 13 degrees.

  18. IMPROVED BACKGROUND SUBTRACTION FOR THE SLOAN DIGITAL SKY SURVEY IMAGES

    International Nuclear Information System (INIS)

    Blanton, Michael R.; Kazin, Eyal; Muna, Demitri; Weaver, Benjamin A.; Price-Whelan, Adrian

    2011-01-01

    We describe a procedure for background subtracting Sloan Digital Sky Survey (SDSS) imaging that improves the resulting detection and photometry of large galaxies on the sky. Within each SDSS drift scan run, we mask out detected sources and then fit a smooth function to the variation of the sky background. This procedure has been applied to all SDSS-III Data Release 8 images, and the results are available as part of that data set. We have tested the effect of our background subtraction on the photometry of large galaxies by inserting fake galaxies into the raw pixels, reanalyzing the data, and measuring them after background subtraction. Our technique results in no size-dependent bias in galaxy fluxes up to half-light radii r 50 ∼ 100 arcsec; in contrast, for galaxies of that size the standard SDSS photometric catalog underestimates fluxes by about 1.5 mag. Our results represent a substantial improvement over the standard SDSS catalog results and should form the basis of any analysis of nearby galaxies using the SDSS imaging data.

  19. Effectiveness of digital subtraction radiography in detecting artificially created osteophytes and erosions in the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Kocasarac, Husniye Demirturk [Dept. of Comprehensive Dentistry, The University of Texas Health Science Center, San Antonio (United States); Celenk, Peruze [Dept. of Oral and Maxillofacial Radiology, Faculty of Dentistry, Ondokuz Mayis University, Samsun (Turkmenistan)

    2017-06-15

    Erosions and osteophytes are radiographic characteristics that are found in different stages of temporomandibular joint (TMJ) osteoarthritis. This study assessed the effectiveness of digital subtraction radiography (DSR) in diagnosing simulated osteophytes and erosions in the TMJ. Five intact, dry human skulls were used to assess the effectiveness of DSR in detecting osteophytes. Four cortical bone chips of varying thicknesses (0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm) were placed at the medial, central, and lateral aspects of the condyle anterior surface. Two defects of varying depth (1.0 mm and 1.5 mm) were created on the lateral, central, and medial poles of the condyles of 2 skulls to simulate erosions. Panoramic images of the condyles were acquired before and after artificially creating the changes. Digital subtraction was performed with Emago dental image archiving software. Five observers familiar with the interpretation of TMJ radiographs evaluated the images. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic accuracy of the imaging methods. The area under the ROC curve (Az) value for the overall diagnostic accuracy of DSR in detecting osteophytic changes was 0.931. The Az value for the overall diagnostic accuracy of panoramic imaging was 0.695. The accuracy of DSR in detecting erosive changes was 0.854 and 0.696 for panoramic imaging. DSR was remarkably more accurate than panoramic imaging in detecting simulated osteophytic and erosive changes. The accuracy of panoramic imaging in detecting degenerative changes was significantly lower than the accuracy of DSR (P<.05). DSR improved the accuracy of detection using panoramic images.

  20. Effectiveness of digital subtraction radiography in detecting artificially created osteophytes and erosions in the temporomandibular joint

    International Nuclear Information System (INIS)

    Kocasarac, Husniye Demirturk; Celenk, Peruze

    2017-01-01

    Erosions and osteophytes are radiographic characteristics that are found in different stages of temporomandibular joint (TMJ) osteoarthritis. This study assessed the effectiveness of digital subtraction radiography (DSR) in diagnosing simulated osteophytes and erosions in the TMJ. Five intact, dry human skulls were used to assess the effectiveness of DSR in detecting osteophytes. Four cortical bone chips of varying thicknesses (0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm) were placed at the medial, central, and lateral aspects of the condyle anterior surface. Two defects of varying depth (1.0 mm and 1.5 mm) were created on the lateral, central, and medial poles of the condyles of 2 skulls to simulate erosions. Panoramic images of the condyles were acquired before and after artificially creating the changes. Digital subtraction was performed with Emago dental image archiving software. Five observers familiar with the interpretation of TMJ radiographs evaluated the images. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic accuracy of the imaging methods. The area under the ROC curve (Az) value for the overall diagnostic accuracy of DSR in detecting osteophytic changes was 0.931. The Az value for the overall diagnostic accuracy of panoramic imaging was 0.695. The accuracy of DSR in detecting erosive changes was 0.854 and 0.696 for panoramic imaging. DSR was remarkably more accurate than panoramic imaging in detecting simulated osteophytic and erosive changes. The accuracy of panoramic imaging in detecting degenerative changes was significantly lower than the accuracy of DSR (P<.05). DSR improved the accuracy of detection using panoramic images

  1. A subtraction scheme for computing QCD jet cross sections at NNLO: integrating the doubly unresolved subtraction terms

    CERN Document Server

    Somogyi, Gabor

    2013-01-01

    We finish the definition of a subtraction scheme for computing NNLO corrections to QCD jet cross sections. In particular, we perform the integration of the soft-type contributions to the doubly unresolved counterterms via the method of Mellin-Barnes representations. With these final ingredients in place, the definition of the scheme is complete and the computation of the regularised doubly virtual contribution to the NNLO cross section becomes feasible.

  2. A subtraction scheme for computing QCD jet cross sections at NNLO: integrating the doubly unresolved subtraction terms

    Science.gov (United States)

    Somogyi, Gábor

    2013-04-01

    We finish the definition of a subtraction scheme for computing NNLO corrections to QCD jet cross sections. In particular, we perform the integration of the soft-type contributions to the doubly unresolved counterterms via the method of Mellin-Barnes representations. With these final ingredients in place, the definition of the scheme is complete and the computation of fully differential rates for electron-positron annihilation into two and three jets at NNLO accuracy becomes feasible.

  3. A subtraction scheme for computing QCD jet cross sections at NNLO: integrating the doubly unresolved subtraction terms

    OpenAIRE

    Somogyi, Gabor

    2013-01-01

    We finish the definition of a subtraction scheme for computing NNLO corrections to QCD jet cross sections. In particular, we perform the integration of the soft-type contributions to the doubly unresolved counterterms via the method of Mellin-Barnes representations. With these final ingredients in place, the definition of the scheme is complete and the computation of fully differential rates for electron-positron annihilation into two and three jets at NNLO accuracy becomes feasible.

  4. Digital subtraction cerebral angiography by intraarterial injection: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Brant-Zawadzki, M.; Gould, R.; Norman, D.; Newton, T.H.; Lane, B.

    1983-01-01

    For 4 months, a prototype digital subtraction system was used to obtain images of the cerebral vasculature after intraarterial contrast injections. In 12 instances, the intraarterial injections were recorded with both a digital subtraction unit and conventional direct magnification film-screen system. The digital subtraction and conventional film subtraction images were compared and graded for quality and information content by three skilled observers. In addition, quantitative measurements of contrast-detail performance and spatial resolution were obtained on both the digital system and the screen-film imaging chain. In a clinical setting, both the digital subtraction and conventional film-screen systems provided similar quality images and angiographic information. Contrast-detail curves demonstrated that digital subtraction angiography outperformed conventional film technique for low-contrast objects. Digital subtraction angiography also reduced the time required to obtain the angiogram, markedly reduced film cost, and lowered the contrast agent burden

  5. Bone Cancer

    Science.gov (United States)

    Cancer that starts in a bone is uncommon. Cancer that has spread to the bone from another ... more common. There are three types of bone cancer: Osteosarcoma - occurs most often between ages 10 and ...

  6. Bone Diseases

    Science.gov (United States)

    Your bones help you move, give you shape and support your body. They are living tissues that rebuild constantly ... childhood and your teens, your body adds new bone faster than it removes old bone. After about ...

  7. Evaluation value of coronary CTA for coronary plaque features and its correlation with platelet function and serum biochemical indexes

    Directory of Open Access Journals (Sweden)

    Jin-Xia Yang

    2017-01-01

    Full Text Available Objective: To analyze the evaluation value of coronary CT angiography for coronary plaque features and its correlation with platelet function and serum biochemical indexes. Methods: A total of 450 patients with coronary heart disease were divided into calcified plaque group (CT value≥130HU (n=117, soft plaque group (CT value≤60HU (n=150 and mixed plaque group (CT value 60-130HU (n=183 by coronary CT angiography (CTA, and 100 healthy subjects who received physical examination in our hospital during the same period were selected as control group. Differences in platelet function and serum biochemical indexes were compared among four groups of patients, and the judgment value of atheromatous plaque CT value from CTA for the severity of coronary heart disease was analyzed. Results: Platelet function parameters MPV, TEG-MA, P-selectin, PDGF-BB and vWF levels in peripheral blood of soft plaque group were higher than those of the other three groups; inflammatory factors CRP, IL-6, IL-12, IL-18 and IL-23 content in serum were higher than those of the other three groups; chemokines MCP-1, CXCL16, Fractalkine and RANTES content in serum were higher than those of the other three groups; adipocytokines Leptin and RBP4 content in serum were higher than those of the other three groups while SFRP5 content was lower than those of the other three groups. Atheromatous plaque CT value in patients with coronary heart disease was directly correlated with platelet function and the content of serum biochemical indexes. Conclusions: Coronary CTA can accurately assess coronary atheromatous plaque features, and can also be a reliable noninvasive method to judge coronary heart disease severity, treatment prognosis and so on.

  8. 35% Good Outcome Rate in IV-tPA treated Patients with CTA Confirmed Severe Anterior Circulation Occlusive Stroke

    Science.gov (United States)

    González, R. Gilberto; Furie, Karen L.; Goldmacher, Gregory V.; Smith, Wade S.; Kamalian, Shervin; Payabvash, Seyedmehdi; Harris, Gordon J.; Halpern, Elkan F.; Koroshetz, Walter J.; Camargo, Erica C. S.; Dillon, William P.; Lev, Michael H.

    2015-01-01

    BACKGROUND AND PURPOSE To determine the effect of IV-tPA on outcomes in patients with severe major anterior circulation ischemic stroke. METHODS Prospectively, 649 acute stroke patients had admission NIH stroke scale scores (NIHSS), non-contrast CT, CT angiography (CTA), and 6-month outcome assessed using modified Rankin scale (mRS). IV-tPA treatment decisions were made prior to CTA, at the time of non-contrast CT scanning, as per routine clinical protocol. Severe symptoms were defined as NIHSS>10. Poor outcome was defined as mRS>2. Major occlusions were identified on CTA. Univariate and multivariate stepwise-forward logistic regression analyses of the full cohort were performed. RESULTS Of 649 patients, 188 (29%) presented with NIHSS>10, and 64/188 (34%) of these received IV-tPA. Admission NIHSS, large artery occlusion, and IV-tPA all independently predicted good outcomes, however a significant interaction existed between IV-tPA and occlusion (p10 patients with anterior circulation occlusion, twice the percentage had good outcomes if they received IV-tPA (17/49, 35%), than if they did not (13/77, 17%; p=0.031). The “number needed to treat” was 7 (95% CI = 3–60). CONCLUSIONS IV-tPA treatment resulted in significantly more good outcomes in severely symptomatic stroke patients with major anterior circulation occlusions. The 35% good outcome rate was similar to rates found in endovascular therapy trials. Vascular imaging may help in patient selection and stratification for trials of IV-thrombolytic and endovascular therapies. PMID:24003051

  9. Probing for Pulsars: An XMM Study of the Composite SNRS G327.1-1.1 and CTA1

    Science.gov (United States)

    Slane, Patrick; Mushotzky, Richard F. (Technical Monitor)

    2003-01-01

    The subject grant is for analysis of XMM data from the supernova remnant CTA1. Our investigation centered on the study of the compact source Rx 50007.0+7302 that, based on our previous observations, appears to be a neutron star powering a wind nebula in the remnant interior. This compact source has also been suggested as the counterpart of the EGRET source 2EG J0008+7307. The analysis of the data from the compact source is complete. We find that the spectrum of the source is well described by a power law with the addition of a soft thermal component that may correspond to emission from hot polar cap regions or to cooling emission from a light element atmosphere over the entire star. There is evidence of extended emission on small spatial scales which may correspond to structure in the underlying synchrotron nebula. Extrapolation of the nonthermal emission component to gamma-ray energies yields a flux that is consistent with that of 2EG J0008+7307, thus strengthening the proposition that there is a gamma-ray emitting pulsar at the center of CTA 1. Our timing studies with the EPIC pn data revealed no evidence for pulsations, however; we set an upper limit of 61% on the pulsed fraction from this source. The results from this study were presented in a poster at the recent IAU Symposium in Sydney, Australia. A paper summarizing these results, entitled "Xray Observations of the Compact Source in CTA 1" (Slane et al.) has been submitted for publication in the Astrophysical Journal.

  10. Lung nodule detection by microdose CT versus chest radiography (standard and dual-energy subtracted).

    Science.gov (United States)

    Ebner, Lukas; Bütikofer, Yanik; Ott, Daniel; Huber, Adrian; Landau, Julia; Roos, Justus E; Heverhagen, Johannes T; Christe, Andreas

    2015-04-01

    The purpose of this study was to investigate the feasibility of microdose CT using a comparable dose as for conventional chest radiographs in two planes including dual-energy subtraction for lung nodule assessment. We investigated 65 chest phantoms with 141 lung nodules, using an anthropomorphic chest phantom with artificial lung nodules. Microdose CT parameters were 80 kV and 6 mAs, with pitch of 2.2. Iterative reconstruction algorithms and an integrated circuit detector system (Stellar, Siemens Healthcare) were applied for maximum dose reduction. Maximum intensity projections (MIPs) were reconstructed. Chest radiographs were acquired in two projections with bone suppression. Four blinded radiologists interpreted the images in random order. A soft-tissue CT kernel (I30f) delivered better sensitivities in a pilot study than a hard kernel (I70f), with respective mean (SD) sensitivities of 91.1%±2.2% versus 85.6%±5.6% (p=0.041). Nodule size was measured accurately for all kernels. Mean clustered nodule sensitivity with chest radiography was 45.7%±8.1% (with bone suppression, 46.1%±8%; p=0.94); for microdose CT, nodule sensitivity was 83.6%±9% without MIP (with additional MIP, 92.5%±6%; pmicrodose CT for readers 1, 2, 3, and 4 were 84.3%, 90.7%, 68.6%, and 45.0%, respectively. Sensitivities with chest radiography for readers 1, 2, 3, and 4 were 42.9%, 58.6%, 36.4%, and 90.7%, respectively. In the per-phantom analysis, respective sensitivities of microdose CT versus chest radiography were 96.2% and 75% (pmicrodose CT, the applied dose was 0.1323 mSv. Microdose CT is better than the combination of chest radiography and dual-energy subtraction for the detection of solid nodules between 5 and 12 mm at a lower dose level of 0.13 mSv. Soft-tissue kernels allow better sensitivities. These preliminary results indicate that microdose CT has the potential to replace conventional chest radiography for lung nodule detection.

  11. Multimodal imaging in the elastase-induced aneurysm model in rabbits: a comparative study using serial DSA, MRA and CTA

    International Nuclear Information System (INIS)

    Doerfler, A.; Becker, W.; Wanke, I.; Goericke, S.; Oezkan, N.; Forsting, M.

    2004-01-01

    Background and Purpose: The elastase-induced aneurysm model in rabbits has proved to be suitable for testing new endovascular occlusion devices. The purpose of this study was to evaluate different imaging modalities for the depiction of anatomy and size of elastase-induced aneurysms and for serial follow-up imaging. Materials and Methods: Elastase-induced aneurysms were created in eight Chinchilla bastard rabbits by endoluminal incubation of porcine elastase. Serial imaging was performed using intravenous DSA (IVDSA), contrast-enhanced MRA (CEMRA), and time-of-flight MRA (TOF) 14 days, 4 weeks and 3 months after aneurysm creation. Intraarterial DSA (IADSA) and CT angiography (CTA) were performed after 3 months. Aneurysm size and geometry (height H, width W, neck width N) were compared. Results: On IVDSA after two weeks mean aneurysm height was 6.2 mm (range 2.8-11.0 mm), mean aneurysm neck width was 2.7 mm (range 2.0-4.2 mm) and mean aneurysm neck width was 2.7 mm (range 2.0-4.2 mm). We did not observed any statistically significant change in aneurysm dimensions during follow-up at 4 weeks (CEMRA: H: 5.4, W: 2.4, N: 2.4; TOF: H: 5.7, W: 2.4, N: 2.7) and 3 months (CEMRA: H: 5.8, W: 2.6, N: 2.6; TOF: H: 6.9, W: 2.8, N: 3.0). Aneurysm dimensions could be best seen on IADSA (H: 6.2, W: 3.0, N: 2.7) with good correlation to CTA (r=0.94; H: 6.1, W: 2.8, N: 2.6), CE-MRA (r=0.92), and TOF (r=0.97). TOF was superior to CEMRA in delineating the aneurysm wall. Conclusions: Serial imaging using MRA, CTA or intravenous and intraarterial angiography is feasible in the elastase-induced aneurysm model. Contrast-enhanced MRA, TOF-MRA and CTA showed good correlation to IADSA and are all suitable for non-invasive pretherapeutic measurement of aneurysm size. (orig.) [de

  12. Digital subtraction angiography in the evaluation of chemodectomas

    International Nuclear Information System (INIS)

    Vlahos, L.; Papathanasiou, M.; Gouliamos, A.; Dimakakos, P.; Papavassiliou, C.

    1988-01-01

    During the last 2 years eleven patients with surgically confirmed chemodectomas have been investigated by means of digital subtraction angiography (DSA). Seven patients underwent i.v. DSA, which revealed eight carotid body tumours, and in the remaining four with jugulotympanic chemodectomas intra-arterial (i.a.) DSA was performed. We found i.v. DSA an easy and satisfactory method for the investigation of carotid body tumours but when glomus intravagale, tympanicum or jugulare is suspected an i.a. selective injection is required. (orig.) [de

  13. Digital subtraction angiography in the evaluation of chemodectomas

    Energy Technology Data Exchange (ETDEWEB)

    Vlahos, L.; Papathanasiou, M.; Gouliamos, A.; Dimakakos, P.; Papavassiliou, C.

    1988-05-01

    During the last 2 years eleven patients with surgically confirmed chemodectomas have been investigated by means of digital subtraction angiography (DSA). Seven patients underwent i.v. DSA, which revealed eight carotid body tumours, and in the remaining four with jugulotympanic chemodectomas intra-arterial (i.a.) DSA was performed. We found i.v. DSA an easy and satisfactory method for the investigation of carotid body tumours but when glomus intravagale, tympanicum or jugulare is suspected an i.a. selective injection is required.

  14. Real-time digital x-ray subtraction imaging

    International Nuclear Information System (INIS)

    Mistretta, C.A.; Kruger, R.A.; Houk, T.L.

    1982-01-01

    A method of producing visible difference images derived from an x-ray image of an anatomical subject is described. X-rays are directed through the subject, and the image is converted into television fields comprising trains of analog video signals. The analog signals are converted into digital signals, which are then integrated over a predetermined time corresponding to several television fields. Difference video signals are produced by performing a subtraction between the ongoing video signals and the corresponding integrated signals, and are converted into visible television difference images representing changes in the x-ray image

  15. Clinical application of digital subtraction angiography for arterial portography

    International Nuclear Information System (INIS)

    Ohtomo, Kuni; Furui, Shigeru; Yashiro, Naofumi; Itai, Yuji; Iio, Masahiro

    1983-01-01

    Intra-arterial digital subtraction portography(IADSP) after superior mesenteric artery injection was described. A total dose of 15 ml to 20 ml of 76% contrast medium was injected at a rate of 5 ml/sec in 14 cases (9 hepatomas, 2 metastatic liver tumors, 2 cavernous hemangiomas, 1 liver cirrhosis). In 11 cases, portal venous system was clearly demonstrated by IADSP. In 8 hepatomas tumor thrombus of portal venous system could be ruled out by IADSP and embolization therapy was carried out. IADSP was also useful for demonstrating esophageal varix and splenorenal shunt. (author)

  16. A subtractive approach to interior intrusion detection system design

    International Nuclear Information System (INIS)

    Sons, R.J.; Graham, R.H. Jr.

    1986-01-01

    This paper discusses the subtractive approach to interior intrusion detection system design which assumes that all sensors are viable candidates until they are subjected to the constraints imposed by a particular facility. The constraints are determined by a sequence of questions concerning parameters such as threat definition, facility description and operation, environment, assets to be protected, security system capabilities, and cost. As a result of the questioning, some sensors will be eliminated from the candidate list, and the ''best'' set of sensors for the facility will remain. This form of questioning could be incorporated into an expert system aiding future intrusion detection system designs

  17. Intra-arterial digital subtraction angiography of the carotid arteries

    International Nuclear Information System (INIS)

    Nakstad, P.; Bakke, S.J.; Kjartansson, O.; Nyhus, S.

    1986-01-01

    A cross-over test in intra-arterial digital subtraction angiography (IADSA) of the carotid arteries was performed in 50 patients to evaluate image quality and side-effects with iohexol and metrizoate injected at concentrations of 100 mg I/ml by hand. The image quality was excellent or good in all cases. Although the severity and the frequency of side-effects were higher with metrizoate, both contrast media were suitable for IADSA at this low concentration. No complications were seen. It was assumed that the risk with IADSA was less than that of conventional-selectivity and with small amounts of contrast media, as in this study. (orig.)

  18. [Design and development of the DSA digital subtraction workstation].

    Science.gov (United States)

    Peng, Wen-Xian; Peng, Tian-Zhou; Xia, Shun-Ren; Jin, Guang-Bo

    2008-05-01

    According to the patient examination criterion and the demands of all related departments, the DSA digital subtraction workstation has been successfully designed and is introduced in this paper by analyzing the characteristic of video source of DSA which was manufactured by GE Company and has no DICOM standard interface. The workstation includes images-capturing gateway and post-processing software. With the developed workstation, all images from this early DSA equipment are transformed into DICOM format and then are shared in different machines.

  19. Microsurgical management of cerebral aneurysms based in CT angiography with three-dimensional reconstruction (3D-CTA) and without preoperative cerebral angiography

    International Nuclear Information System (INIS)

    Gonzalez-Darder, J.M.; Pesudo-Martinez, J.V.; Feliu-Tatay, R.A.

    2001-01-01

    Objective. To study the possibilities of the microsurgical management of ruptured intracranial aneurysms with the sole preoperative information provided by computed tomography angiography with three-dimensional reconstruction (3D-CTA). Methods. Patients were studied with 3D-CTA after diagnosis of subarachnoid hemorrhage. If the study had an adequate quality and revealed an aneurysm congruent with the clinical findings or neurological examination and/or with the location of the bleeding on computed tomography (CT) scan an early microsurgical clipping of the lesion was done. When the quality of the 3D-CTA study was not adequate or the quality being adequate displayed no lesions or the findings were not accurate enough to warrant direct microsurgical treatment, the patient was studied with cerebral digital substraction (DS) angiography. A total of 44 consecutive patients harboring a total of 47 intracranial aneurysms diagnosed by 3D-CTA and without preoperative DS angiography were submitted to microsurgical clipping and included in the study. Results. The overall mortality was 15.9 % and the favorable results evaluated 6 months after discharge by means of the Glasgow outcome scale reached 70.4 %. All lesions were successfully clipped. Surgery was done a mean of 4.1 days after the admission bleeding. A total of four microlesions undiagnosed by 3D-CTA were found at surgery and clipped. Postoperative DS angiography and necropsy findings were also used as control of the 3D-CTA findings but no additional information was provided excepting the finding in DS angiography of an asymptomatic intracavemous aneurysm. Therefore the sensitivity of the 3D-CTA for diagnosis of symtomatic aneurysms was 100 % and the overall sensitivity 90.4 %. Conclusions. We have reached similar results in patients operated on with or without preoperative angiography. 3D-CTA provides very valuable anatomical information, which has an additional value in the microsurgical treatment of aneurysms of the

  20. The diagnostic accuracy of TCD for intracranial arterial stenosis/occlusion in patients with acute ischemic stroke: the importance of time interval between detection of TCD and CTA.

    Science.gov (United States)

    Guan, Jingxia; Zhou, Qin; Ouyang, Huangqing; Zhang, Shaofeng; Lu, Zuneng

    2013-11-01

    To evaluate prospectively the diagnostic accuracy of transcranial doppler (TCD) as an additional screening tool for intracranial arterial steno-occlusive disease against computed tomography angiography (CTA) in patients with acute ischemic stroke (AIS) if both are performed in a short time interval. Between July 2011 and May 2012, 128 patients who were hospitalized within 24 hours of symptom onset and fulfilled the criteria for the clinical diagnosis of AIS were enrolled. Bedside detection of TCD was accomplished immediately after admission. High-resolution brain CTA was performed within 3 hours after the completion of TCD and the images were interpreted by a neuroradiologist blinded to TCD findings. The accuracy parameters of TCD against CTA were calculated after computation of true-positive, false-positive, true negative, and false-negative values. Among the 128 patients, there were 68 males and 60 females, aged 61.4 ± 17.5 years. The mean time interval between the detection of TCD and CTA was 89.7 (77.8) minutes. In 65% of patients, both examinations were performed with less than a half-hour interval between them. The diagnostic accuracy of TCD for different arteries showed slight distinction. Transcranial doppler demonstrated the most accurate diagnosis for middle cerebral artery (MCA), where TCD showed 35 true-positive, 0 false-negative, 1 false-positive, and 92 true-negative studies compared with CTA. Furthermore, elevated MCA velocities on TCD correlated well with the severity of intracranial stenosis detected on CTA. Vertebral artery (VA) is one of the arteries with the lowest sensitivity for TCD diagnosis (sensitivity 63.4%, specificity 96.5%, positive predictive value (PPV) 89.6%, negative predictive value (NPV) 84.8%, and accuracy 85.9%). In 20 cases (15.6%), TCD showed findings complementary to CTA (real-time embolization, collateral flow patterns, and steal phenomenon). Transcranial doppler shows high diagnostic accuracy against CTA if both are

  1. Bone-suppressed radiography using machine learning

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jun Beom; Kim, Dae Cheon; Kim, Ho Kyung [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The single-shot dual-energy imaging suffers from reduced contrast-to-noise ratio performance due to poor spectral separation. Tomosynthesis requires more complex motion equipment and may require higher patient dose. An alternative tissue-specific imaging technique was introduced. This alternative technique usually possesses a filter to generate bone-only images for given digital radiographs. Therefore, it provides soft-tissue-enhanced images from the subtraction of given radiographs and filtered bone-only images. Only bone-suppressed imaging capability is a limitation of the method. The filter can be obtained from a machine-learning algorithm, e.g. artificial neural network (ANN), with the dual-energy bone-only images (called 'teaching' images). We suspect the robustness of the filter may be dependent upon the number of teaching images and the number of patients from whose radiographs we obtain the teaching images. In this study, we design an ANN to obtain a bone-extracting filter from a radiograph, and investigate the filter properties with respect to various ANN parameters. Preliminary results are summarized in Fig. 3. We extracted 5,000 subregions in a 21x21 pixel format from the lung region in the bone-enhanced dual-energy image and we used them for teaching images during training the ANN. The resultant bone-enhanced image from the ANN nonlinear filter is shown in Fig. 3 (a). From the weighted logarithmic subtraction between Fig. 2 (a) and Fig. 3 (a), we could obtain the bone-suppressed image as shown in Fig. 3 (b). The quality of the bone-suppressed image is comparable to the ground truth Fig. 2 (c).

  2. Bone-suppressed radiography using machine learning

    International Nuclear Information System (INIS)

    Park, Jun Beom; Kim, Dae Cheon; Kim, Ho Kyung

    2016-01-01

    The single-shot dual-energy imaging suffers from reduced contrast-to-noise ratio performance due to poor spectral separation. Tomosynthesis requires more complex motion equipment and may require higher patient dose. An alternative tissue-specific imaging technique was introduced. This alternative technique usually possesses a filter to generate bone-only images for given digital radiographs. Therefore, it provides soft-tissue-enhanced images from the subtraction of given radiographs and filtered bone-only images. Only bone-suppressed imaging capability is a limitation of the method. The filter can be obtained from a machine-learning algorithm, e.g. artificial neural network (ANN), with the dual-energy bone-only images (called 'teaching' images). We suspect the robustness of the filter may be dependent upon the number of teaching images and the number of patients from whose radiographs we obtain the teaching images. In this study, we design an ANN to obtain a bone-extracting filter from a radiograph, and investigate the filter properties with respect to various ANN parameters. Preliminary results are summarized in Fig. 3. We extracted 5,000 subregions in a 21x21 pixel format from the lung region in the bone-enhanced dual-energy image and we used them for teaching images during training the ANN. The resultant bone-enhanced image from the ANN nonlinear filter is shown in Fig. 3 (a). From the weighted logarithmic subtraction between Fig. 2 (a) and Fig. 3 (a), we could obtain the bone-suppressed image as shown in Fig. 3 (b). The quality of the bone-suppressed image is comparable to the ground truth Fig. 2 (c).

  3. Clinical application of lower extremity CTA and lower extremity perfusion CT as a method of diagnostic for lower extremity atherosclerotic obliterans

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Il Bong; Dong, Kyung Rae [Dept. Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of); Goo, Eun Hoe [Dept. Radiological Science, Cheongju University, Cheongju (Korea, Republic of)

    2016-11-15

    The purpose of this study was to assess clinical application of lower extremity CTA and lower extremity perfusion CT as a method of diagnostic for lower extremity atherosclerotic obliterans. From January to July 2016, 30 patients (mean age, 68) were studied with lower extremity CTA and lower extremity perfusion CT. 128 channel multi-detector row CT scans were acquired with a CT scanner (SOMATOM Definition Flash, Siemens medical solution, Germany) of lower extremity perfusion CT and lower extremity CTA. Acquired images were reconstructed with 3D workstation (Leonardo, Siemens, Germany). Site of lower extremity arterial occlusive and stenosis lesions were detected superficial femoral artery 36.6%, popliteal artery 23.4%, external iliac artery 16.7%, common femoral artery 13.3%, peroneal artery 10%. The mean total DLP comparison of lower extremity perfusion CT and lower extremity CTA, 650 mGy-cm and 675 mGy-cm, respectively. Lower extremity perfusion CT and lower extremity CTA were realized that were never be two examination that were exactly the same legions. Future through the development of lower extremity perfusion CT soft ware programs suggest possible clinical applications.

  4. Comparison of conventional panoramic radiography and panoramic digital subtraction radiography in detection of simulated lesions of mandibular condyle

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2008-12-01

    Full Text Available "n  "nBackground and Aim: Digital subtraction Radiography (DSR is a method of accurate assessing condylar head changes. several studies have been carried out in applying DSR in dentistry, however there is a few number of studies in efficacy of DSR method in assesment of condylar head changes, The aim of this study was to compare panoramic radiography and DSR detecting simulated lesions of the mandibular condyl. "nMaterials and Methods: this was a process reaserch study, in which two dry human skulls with no obvious temporomandibular joint pathology were used. Osteophytic lesions were simulated using three sizes of bone chips that were placed on the medial portion of anterior and superolateral aspects of the condyle. Osteolytic lesions were simulated making 1 and 2 mm holes using round burr in the central portion of anterior aspect and Lateral pole of the condyle. Panoramic radiographs were prepared with and without the lesions in place. These paired radiographs were digitized and digital- subtraction images of the original panoramic images were obtained. Eight observers evaluated 155 images of each modality for the presence or absence and the type of simulated lesions of the mandibular condyle. Sensitivity, specificity, reliability and measure of agreement were analyzed using kappa test and crossed tables and qualitative variables were assess by chi-square and fisher's Exact test. "nResults: Specificity of panoramic and DSR methods were 15.4% and 66.7% respectively. Sensitivity of panoramic and DSR methods were 61.1% and 80.6% for osteophytic lesions and 37.5% and 83.3% for Osteolytic lesions. The percentage of correct decisions made in DSR method was significantly more than conventional panoramic method (82.6% vs 41.9% (p<0.0001. "nConclusion: Based on the results of this study digital subtraction technique was significantly more accurate than the panoramic radiographs in detection of simulated lesions of the mandibular condyle.

  5. Dosimetry in the region of 0.25 Mrad and 25 Mrad using cellulose triacetate films (CTA)

    International Nuclear Information System (INIS)

    Dafferner, J.M.

    1978-01-01

    The dosimetric characteristics of a cellulose triacetate dosimetric film (CTA) from different places of origin, recently placed on the market to be used in dosimetry, are investigated. The charge in the optical absorption in the ultraviolet region induced by gamma radiation of Co-60 is found to be a linear behavior with the absorbed total dose, within a range of 0.25 to 25 Megarad. For the spectrophotometric reading the wavelength of 290 nm was chosen for the French CTA film, while 294 nm was used for the Japanese one. The response of the film is stable in time after the irradiation. By means of an adequate and careful handling the response does not change. One must always maintain, in practical usage, the same conditions of irradiation and the spectrophotometric reading used in the calibration. This film appears well suited for monitoring and control the dose of industrial irradiation process such as: process that involve application of chemical effects undergo by polymers when irradiated (polymerization), radiosterilization of medical products and equipments, food sterillization etc. (Author) [pt

  6. Fatty degeneration of the rotator cuff muscles on pre- and postoperative CT arthrography (CTA): is the Goutallier grading system reliable?

    International Nuclear Information System (INIS)

    Lee, Eugene; Choi, Jung-Ah; Kang, Heung Sik; Oh, Joo Han; Ahn, Soyeon; Hong, Sung Hwan; Chai, Jee Won

    2013-01-01

    To retrospectively evaluate fatty degeneration (FD) of rotator cuff muscles on CTA using Goutallier's grading system and quantitative measurements with comparison between pre- and postoperative states. IRB approval was obtained for this study. Two radiologists independently reviewed pre- and postoperative CTAs of 43 patients (24 males and 19 females, mean age, 58.1 years) with 46 shoulders confirmed as full-thickness tears with random distribution. FD of supraspinatus, infraspinatus/teres minor, and subscapularis was assessed using Goutallier's system and by quantitative measurements of Hounsfield units (HUs) on sagittal images. Changes in FD grades and HUs were compared between pre- and postoperative CTAs and analyzed with respect to preoperative tear size and postoperative cuff integrity. The correlations between qualitative grades and quantitative measurements and their inter-observer reliabilities were also assessed. There was statistically significant correlation between FD grades and HU measurements of all muscles on pre- and postoperative CTA (p 0.05). The average dose-length product (DLP, mGy . cm) was 365.2 mGy . cm (range, 323.8-417.2 mGy . cm) and estimated average effective dose was 5.1 mSv. Goutallier grades correlated well with HUs of rotator cuff muscles. Reliability was excellent for both systems, except for FD grade of IST/TM muscles, which may be more reliably assessed using quantitative measurements. (orig.)

  7. Evaluation of left ventricular function using digital subtraction ventriculography

    International Nuclear Information System (INIS)

    Yiannikas, J.; Detrano, R.

    1986-01-01

    Digital subtraction ventriculography following injections of contrast via peripheral veins provides excellent images to assess left ventricular function. The images are essentially identical to those following DCV, but allow more uniform mixing of contrast in the left ventricular chamber. Furthermore, few, if any, cardiac arrhythmias occur, hence obviating difficulties that arise from DCV. The spatial resolution of the method is such that regional wall motion assessment of ventricular function is more accurate than that of other noninvasive imaging methods. The use of video-densitometry allows accurate assessment of left ventricular function even when the left ventricular cavity is nonsymmetrically deformed and aneurysmal. In the setting of the cardiac catheterization laboratory, digital ventriculography may provide a safer means of assessing left ventricular function when critical coronary or myocardial disease is present and allows multiple assessments of ventricular function during the same study. Although excellent correlations with standard ventriculography have been noted by all workers, significant discrepancies still exist in individual patients, particularly in the calculations of end diastolic volumes. In the authors experience and in those of most workers, the largest discrepancies existed in patients in whom suboptimal studies are included for analysis. The most frequent reason for the occasional suboptimal study as with all digital subtraction work is the misregistration that results from motion

  8. Digital subtraction angiography in 105 living renal transplant donors

    International Nuclear Information System (INIS)

    Suh, Ho Jong; Oh, Kyung Seung; Kim, So Sun; Huh, Jin Do; Kim, Ho Joon; Chun, Byung Hee; Joh, Young Duck

    1989-01-01

    In order to analyze the number and length of the renal arteries and to evaluate abnormalities of the renal parenchyma and vessel, digital subtraction angiogram images of 105 potential renal donors (45 men and 60 women aged 17-66 years) were studied retrospectively. For the entire series, 31 donors had multiple renal arteries on one side (15 on the left, 11 on the right) and 5 donors on the both sides. 89 donors were family related either parents or siblings of recipients. The estimation of the length of the renal artery was based on the mean height of the second lumbar vertebral body (L2). The right renal artery is significant longer than on the left and measured more than the height of L2 vertebral body in 84 cases on the right and 60 cases on the left. Twenty two donors underwent right nephrectomy due to presence of multiple renal arteries on the left (N=14), proximal bifurcation of left main renal artery (N=3), and young females in reproductive age (N=5). Unexpected abnormalities found with angiogram were seen in 7 cases and they include renal artery stenosis (N=2), renal cysts (N=4) and focal infarction (N=1). In cases of the renal cysts and focal infarction, there were no serious complications related to the abnormalities. It is conclude that intra-arterial digital subtraction angiography is safe and efficient method to image renal anatomy of the potential renal donors

  9. Intraarterial digital subtraction angiography applied to diagnosis of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, Sadahiko; Sano, Akira; Imanaka, Kazufumi; Sasai, Keisuke; Nagae, Toshiyuki; Mizutani, Masaru; Hatabu, Hiroto; Sadatou, Norihiro; Kuroda, Yasumasa

    1985-12-01

    This paper deals with diagnostic values of intraarterial digital subtraction angiography (IADSA) for evaluating hepatocellular carcinoma. The present series consists of 44 patients with hepatocellular carcinoma, who underwent IADSA combined with conventional hepatic angiography 67 times in total. The evaluated vessels by IADSA included 70 hepatic arteries and 36 portal veins. Comparative studies on the image quality of IADSA with conventional angiography were made in referring to the tumor stain for arteriograms and resolution of intrahepatic portal branches for portograms. Diagnostic superiority including equality of DSA image to conventional was noted in arteriograms: 72.7 % in the right lobe and 86 % in the left. Most deteriorated DSA images were caused by misregistration artifacts. IADSA portography revealed basically diagnostic values to demonstrate lobar, segmental or more peripheral branches in about 95 % of cases studied. DSA, characterized by high contrast resolution and real-time subtraction, offered important and effective informations for interventional angiography as well as resectability of the tumors, requiring less contrast medium.

  10. Iodine filter imaging system for subtraction angiography using synchrotron radiation

    Science.gov (United States)

    Umetani, K.; Ueda, K.; Takeda, T.; Itai, Y.; Akisada, M.; Nakajima, T.

    1993-11-01

    A new type of real-time imaging system was developed for transvenous coronary angiography. A combination of an iodine filter and a single energy broad-bandwidth X-ray produces two-energy images for the iodine K-edge subtraction technique. X-ray images are sequentially converted to visible images by an X-ray image intensifier. By synchronizing the timing of the movement of the iodine filter into and out of the X-ray beam, two output images of the image intensifier are focused side by side on the photoconductive layer of a camera tube by an oscillating mirror. Both images are read out by electron beam scanning of a 1050-scanning-line video camera within a camera frame time of 66.7 ms. One hundred ninety two pairs of iodine-filtered and non-iodine-filtered images are stored in the frame memory at a rate of 15 pairs/s. In vivo subtracted images of coronary arteries in dogs were obtained in the form of motion pictures.

  11. Temporal digital subtraction radiography with a personal computer digital workstation

    International Nuclear Information System (INIS)

    Kircos, L.; Holt, W.; Khademi, J.

    1990-01-01

    Technique have been developed and implemented on a personal computer (PC)-based digital workstation to accomplish temporal digital subtraction radiography (TDSR). TDSR is useful in recording radiologic change over time. Thus, this technique is useful not only for monitoring chronic disease processes but also for monitoring the temporal course of interventional therapies. A PC-based digital workstation was developed on a PC386 platform with add-in hardware and software. Image acquisition, storage, and processing was accomplished using 512 x 512 x 8- or 12-bit frame grabber. Software and hardware were developed to accomplish image orientation, registration, gray scale compensation, subtraction, and enhancement. Temporal radiographs of the jaws were made in a fixed and reproducible orientation between the x-ray source and image receptor enabling TDSR. Temporal changes secondary to chronic periodontal disease, osseointegration of endosseous implants, and wound healing were demonstrated. Use of TDSR for chest imaging was also demonstrated with identification of small, subtle focal masses that were not apparent with routine viewing. The large amount of radiologic information in images of the jaws and chest may obfuscate subtle changes that TDSR seems to identify. TDSR appears to be useful as a tool to record temporal and subtle changes in radiologic images

  12. Subtractive fabrication of ferroelectric thin films with precisely controlled thickness

    Science.gov (United States)

    Ievlev, Anton V.; Chyasnavichyus, Marius; Leonard, Donovan N.; Agar, Joshua C.; Velarde, Gabriel A.; Martin, Lane W.; Kalinin, Sergei V.; Maksymovych, Petro; Ovchinnikova, Olga S.

    2018-04-01

    The ability to control thin-film growth has led to advances in our understanding of fundamental physics as well as to the emergence of novel technologies. However, common thin-film growth techniques introduce a number of limitations related to the concentration of defects on film interfaces and surfaces that limit the scope of systems that can be produced and studied experimentally. Here, we developed an ion-beam based subtractive fabrication process that enables creation and modification of thin films with pre-defined thicknesses. To accomplish this we transformed a multimodal imaging platform that combines time-of-flight secondary ion mass spectrometry with atomic force microscopy to a unique fabrication tool that allows for precise sputtering of the nanometer-thin layers of material. To demonstrate fabrication of thin-films with in situ feedback and control on film thickness and functionality we systematically studied thickness dependence of ferroelectric switching of lead-zirconate-titanate, within a single epitaxial film. Our results demonstrate that through a subtractive film fabrication process we can control the piezoelectric response as a function of film thickness as well as improve on the overall piezoelectric response versus an untreated film.

  13. Motion compensation in digital subtraction angiography using graphics hardware.

    Science.gov (United States)

    Deuerling-Zheng, Yu; Lell, Michael; Galant, Adam; Hornegger, Joachim

    2006-07-01

    An inherent disadvantage of digital subtraction angiography (DSA) is its sensitivity to patient motion which causes artifacts in the subtraction images. These artifacts could often reduce the diagnostic value of this technique. Automated, fast and accurate motion compensation is therefore required. To cope with this requirement, we first examine a method explicitly designed to detect local motions in DSA. Then, we implement a motion compensation algorithm by means of block matching on modern graphics hardware. Both methods search for maximal local similarity by evaluating a histogram-based measure. In this context, we are the first who have mapped an optimizing search strategy on graphics hardware while paralleling block matching. Moreover, we provide an innovative method for creating histograms on graphics hardware with vertex texturing and frame buffer blending. It turns out that both methods can effectively correct the artifacts in most case, as the hardware implementation of block matching performs much faster: the displacements of two 1024 x 1024 images can be calculated at 3 frames/s with integer precision or 2 frames/s with sub-pixel precision. Preliminary clinical evaluation indicates that the computation with integer precision could already be sufficient.

  14. Counting the mismatches - lung ventilation/perfusion subtraction index

    International Nuclear Information System (INIS)

    Anderson, T.C.; Evans, S.G.; Larcos, G.; Farlow, D.C.

    1998-01-01

    Full text: There is potential for interobserver variability in interpretation of ventilation/perfusion (V/Q) scans. Objective quantification of V/Q mismatch could be useful. Thus, the aim of this study is to determine the validity of image subtraction in a group of 27 patients (11 men, 8 women; mean age 59.4 years [range 21-81 years])investigated by V/Q scans for suspected pulmonary emboli. A standard 6 view V/Q scan was obtained with two cobalt markers used on the anterior and posterior surfaces for image alignment. Ventilation images were normalised to the perfusion using an area of normal ventilation and perfusion. With the use of automated, and if required, manual alignment, perfusion images were subtracted from ventilation, with a median filter applied. A summed index of mismatch for each lung scan was calculated from the difference. This index was then retrospectively compared to the result reported by one of four experienced physicians. Two patients with chronic obstructive airways disease were excluded from analysis. We conclude that high probability V/Q scans can be differentiated from low probability studies using this index; further prospective investigation in a larger cohort is warranted

  15. The oblique occipital sinus: anatomical study using bone subtraction 3D CT venography.

    Science.gov (United States)

    Shin, Hwa Seon; Choi, Dae Seob; Baek, Hye Jin; Choi, Ho Cheol; Choi, Hye Young; Park, Mi Jung; Kim, Ji Eun; Han, Jeong Yeol; Park, SungEun

    2017-06-01

    An occipital sinus draining into the sigmoid sinus has been termed the oblique occipital sinus (OOS). The frequency, anatomical features, patterns, and relationship with the transverse sinus of the oblique occipital sinus were analyzed in this study. The study included 1805 patients who underwent brain CT angiography during a 3-year period from 2013 to 2015. CT examinations were performed using a 64-slice MDCT system. The OOS was identified in 41 patients (2.3%). There were many anatomical variations in the oblique occipital sinuses. A hypoplastic or aplastic TS was seen in 31 (75.6%) of the 41 patients with OOS. Many anatomical variations in the oblique occipital sinus can be seen on CT venography. Some OOSs function as the main drainage route of the intracranial veins instead of the TS. Thus, careful examination is essential for preoperative evaluation in posterior fossa lesions.

  16. [sup 99m]Tc-RBC subtraction scintigraphy; Assessmet of bleeding site and rate

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Kuranishi, Makoto; Sugishita, Kouki; Nakamura, Mamoru (Toyama Medical and Pharmaceutical Univ. (Japan). Hospital)

    1994-03-01

    Sequential abdominal scintigrams with [sup 99m]Tc-labelled red blood cells (RBC) were subtracted for observing a site of gastrointestinal bleeding and calculating the bleeding rate. This method is technically very easy and can detect the site of bleeding with the minimum rate, as low as 0.2 ml/min., in a phantom experiment. In 23 cases with final diagnosis of gastrointestinal bleeding, conventional non-subtraction scintigraphy detected only 30% (7/23), but subtraction scintigraphy detected 61% (14/23). It was concluded that subtraction scintigraphy had higher sensitivity than conventional scintigraphy for early diagnosing bleeding. A combination of non-subtraction and subtraction scintigraphy is recommended to detect a site of gastrointestinal bleeding in a clinical setting. (author).

  17. Sacroiliac joint luxation after pedicle subtraction osteotomy: report of two cases and analysis of failure mechanism.

    Science.gov (United States)

    Charles, Yann Philippe; Yu, Bo; Steib, Jean-Paul

    2016-05-01

    Sagittal decompensation after pedicle subtraction osteotomy (PSO) is considered as late onset complication. Several mechanisms have been suggested, but little attention has been paid to the caudal end of lumbar instrumented fusion, especially sacral iliac joint (SIJ) deterioration. Clinical histories and radiographic sagittal parameters of two patients with SIJ luxation after PSO are presented. The biomechanical failure mechanism and risk factors are analysed. Two patients underwent correction of fixed anterior sagittal imbalance by PSO, followed by pseudarthrosis revision surgery. Both of them sustained persistent sacroiliac pain, progressive recurrence of anterior imbalance and progressive pelvic incidence (PI) increase around 10°. An acute bilateral SIJ luxation occurred in both patients leading to sharp increase or PI around 20°. One patient was treated by SIJ fusion and the other patient was placed on non-weight-bearing crutch ambulation for 1 year. Both patients had a high preoperative PI (95° and 78°). A theoretical match between lumbar lordosis (LL) and PI was not achieved by PSO. Osteopenia was present in both patients. Computed tomography evidenced L5-S1 pseudarthrosis and sacroiliac joint violation by pelvic or sacral ala screws. Patients with high PI might seek for further compensation at their SIJ when lacking LL after PSO. Chronic anterior imbalance might lead to progressive weakening of sacroiliac ligaments. Initial circumferential lumbosacral fusion and accurate iliac screw fixation might reduce stress on implants, risk for pseudarthrosis, implant failure and finally SIJ deterioration. Bone mineral density should further be investigated preoperatively.

  18. Subcomponent vaccine based on CTA1-DD adjuvant with incorporated UreB class II peptides stimulates protective Helicobacter pylori immunity.

    Science.gov (United States)

    Nedrud, John G; Bagheri, Nayer; Schön, Karin; Xin, Wei; Bergroth, Hilda; Eliasson, Dubravka Grdic; Lycke, Nils Y

    2013-01-01

    A mucosal vaccine against Helicobacter pylori infection could help prevent gastric cancers and peptic ulcers. While previous attempts to develop such a vaccine have largely failed because of the requirement for safe and effective adjuvants or large amounts of well defined antigens, we have taken a unique approach to combining our strong mucosal CTA1-DD adjuvant with selected peptides from urease B (UreB). The protective efficacy of the selected peptides together with cholera toxin (CT) was first confirmed. However, CT is a strong adjuvant that unfortunately is precluded from clinical use because of its toxicity. To circumvent this problem we have developed a derivative of CT, the CTA1-DD adjuvant, that has been found safe in non-human primates and equally effective compared to CT when used intranasally. We genetically fused the selected peptides into the CTA1-DD plasmid and found after intranasal immunizations of Balb/c mice using purified CTA1-DD with 3 copies of an H. pylori urease T cell epitope (CTA1-UreB3T-DD) that significant protection was stimulated against a live challenge infection. Protection was, however, weaker than with the gold standard, bacterial lysate+CT, but considering that we only used a single epitope in nanomolar amounts the results convey optimism. Protection was associated with enhanced Th1 and Th17 immunity, but immunizations in IL-17A-deficient mice revealed that IL-17 may not be essential for protection. Taken together, we have provided evidence for the rational design of an effective mucosal subcomponent vaccine against H. pylori infection based on well selected protective epitopes from relevant antigens incorporated into the CTA1-DD adjuvant platform.

  19. Subcomponent vaccine based on CTA1-DD adjuvant with incorporated UreB class II peptides stimulates protective Helicobacter pylori immunity.

    Directory of Open Access Journals (Sweden)

    John G Nedrud

    Full Text Available A mucosal vaccine against Helicobacter pylori infection could help prevent gastric cancers and peptic ulcers. While previous attempts to develop such a vaccine have largely failed because of the requirement for safe and effective adjuvants or large amounts of well defined antigens, we have taken a unique approach to combining our strong mucosal CTA1-DD adjuvant with selected peptides from urease B (UreB. The protective efficacy of the selected peptides together with cholera toxin (CT was first confirmed. However, CT is a strong adjuvant that unfortunately is precluded from clinical use because of its toxicity. To circumvent this problem we have developed a derivative of CT, the CTA1-DD adjuvant, that has been found safe in non-human primates and equally effective compared to CT when used intranasally. We genetically fused the selected peptides into the CTA1-DD plasmid and found after intranasal immunizations of Balb/c mice using purified CTA1-DD with 3 copies of an H. pylori urease T cell epitope (CTA1-UreB3T-DD that significant protection was stimulated against a live challenge infection. Protection was, however, weaker than with the gold standard, bacterial lysate+CT, but considering that we only used a single epitope in nanomolar amounts the results convey optimism. Protection was associated with enhanced Th1 and Th17 immunity, but immunizations in IL-17A-deficient mice revealed that IL-17 may not be essential for protection. Taken together, we have provided evidence for the rational design of an effective mucosal subcomponent vaccine against H. pylori infection based on well selected protective epitopes from relevant antigens incorporated into the CTA1-DD adjuvant platform.

  20. Combined nuclear and digital subtraction contrast arthrography in painful knee prosthesis

    International Nuclear Information System (INIS)

    Namasivayam, J.; Forrester, A.; Poon, F.W.; Cuthbert, G.F.; McKillop, J.H.; Bryan, A.S.

    1992-01-01

    The evaluation of a painful knee prosthesis remains a difficult problem for both orthopaedic surgeons and radiologists. We have compared digital subtraction arthrography with nuclear-arthrography in 7 patients with a painful knee prosthesis. Three patients showed a loose tibial component, demonstrated by both digital subtraction and nuclear arthrography. All 3 underwent revision of their prosthesis. One patient had an equivocal digital subtraction arthrogram and negative nuclear arthrogram, while both studies were negative in the 3 remaining patients. Nuclear arthrography is a simple procedure and can provide useful additional information when combined with digital subtraction arthrography. (orig.)

  1. Arthrography of painful hips following arthroplasty: Digital versus plain film subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Walker, C W; FitzRandolph, R L; Dalrymple, G V [Arkansas Univ. for Medical Sciences, Little Rock, AR (USA). Dept. of Radiology John McClellan Memorial Veterans Hospital, Little Rock, AR (USA); Collins, D N [Arkansas Univ. for Medical Sciences, Little Rock, AR (USA). Dept. of Orthopedics John McClellan Memorial Veterans Hospital, Little Rock, AR (USA)

    1991-08-01

    Digital and manual subtraction images obtained during the arthrographic evaluation of 78 painful hip prostheses were reviewed retrospectively. Revision arthroplasty was performed in 53 of these cases, and the arthrographic and surgical findings were correlated. The digital and manual subtraction images were evaluated without knowledge of the surgical results using established criteria for component loosening. The difference between detection of femoral component loosening on digital as opposed to manual subtraction images was statistically significant (P < 0.05). This study demonstrates that digital subtraction improves the evaluation of femoral component loosening in painful hip prostheses. (orig./GDG).

  2. Parathyroid and bone imaging in primary hyperparathyroidism

    Institute of Scientific and Technical Information of China (English)

    ZHU Rui-Sen; LU Han-Kui; LUO Quan-Yong; CHEN Li-Bo; MA Ji-Xiao

    2004-01-01

    Skeletal derangements occur quite often in patient with primary hyperparathyroidism (PHPT). We investigated parathyroid and bone imagings in 59 cases of pathologically proven PHPT. Forty-nine cases were pathologically proven parathyroid adenomas; 8 presented hyperplasia and the other 2 were adenocarcinomas. Parathyroid imaging (early phase imaging, EPI) was conducted at 30 min after injecting 740~925MBq 99mTc-MIBI and 2~3h later (delayed phase imaging, DPI) separately. The following thyroid imagings were performed at the same posture 10 min after intravenous injection of 74~111MBq 99mTcO4-. The 99mTc- MIBI subtraction imaging data were obtained by subtracting thyroid imaging from that of DPI. Among 49 cases of proven hyperparathyroid adenoma 45 yielded positive imagings. Eight cases with hyperplasia gave negative results. The results were positive in 2 cases of parathyroid adenocarcinoma. Results of 99mTc-MDP/bone imaging: 35 cases of hyperparathyroid adenocarcinoma (disease duration 1-6 months) showed normal bone images, while 14 cases showed superscan images, course being 4-12 months. Bone imaging for 2 cases of adenocarcinoma showed multiple, radioactive aggregated foci (brown tumor imaging); course lasting 10-24 months. The results of bone imaging in 8 cases of hyperplasia/ hyperparathyroidism were normal. It was concluded that diagnostic accuracy for parathyroid was 79.6% and for parathyroid adenoma was 91.8%, and the technique has no diagnostic value for hyperplasia. The 99mTc-MDP / bone imaging results for PHPT can be classified into three categories, i.e. normal, superscan and brown tumor. The imaging results correlated well with the different categories and degrees of bone damage, the duration of clinical course and the pathological types. Therefore, it's important to use bone imaging data in association with therapy to reflect the stage and progress of PHPT.

  3. Bone marrow aspiration

    Science.gov (United States)

    Iliac crest tap; Sternal tap; Leukemia - bone marrow aspiration; Aplastic anemia - bone marrow aspiration; Myelodysplastic syndrome - bone marrow aspiration; Thrombocytopenia - bone marrow aspiration; Myelofibrosis - bone marrow aspiration

  4. Fatty degeneration of the rotator cuff muscles on pre- and postoperative CT arthrography (CTA): is the Goutallier grading system reliable?

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eugene; Choi, Jung-Ah; Kang, Heung Sik [Seoul National University Bundang Hospital, Department of Radiology, Seongnam-si, Gyeongi-do (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, 28 Yeongon-dong, Chongno-gu, Seoul (Korea, Republic of); Oh, Joo Han [Seoul National University Bundang Hospital, Department of Orthopedic Surgery, Seongnam-si, Gyeongi-do (Korea, Republic of); Ahn, Soyeon [Seoul National University Bundang Hospital, Medical Research Collaborating Center, Seongnam-si, Gyeongi-do (Korea, Republic of); Hong, Sung Hwan [Seoul National University College of Medicine, Department of Radiology, 28 Yeongon-dong, Chongno-gu, Seoul (Korea, Republic of); Chai, Jee Won [SMG-SNU Boramae Medical Center, Department of Radiology, 425 Shindaebang-dong, Dongjak-gu, Seoul (Korea, Republic of)

    2013-09-15

    To retrospectively evaluate fatty degeneration (FD) of rotator cuff muscles on CTA using Goutallier's grading system and quantitative measurements with comparison between pre- and postoperative states. IRB approval was obtained for this study. Two radiologists independently reviewed pre- and postoperative CTAs of 43 patients (24 males and 19 females, mean age, 58.1 years) with 46 shoulders confirmed as full-thickness tears with random distribution. FD of supraspinatus, infraspinatus/teres minor, and subscapularis was assessed using Goutallier's system and by quantitative measurements of Hounsfield units (HUs) on sagittal images. Changes in FD grades and HUs were compared between pre- and postoperative CTAs and analyzed with respect to preoperative tear size and postoperative cuff integrity. The correlations between qualitative grades and quantitative measurements and their inter-observer reliabilities were also assessed. There was statistically significant correlation between FD grades and HU measurements of all muscles on pre- and postoperative CTA (p < 0.05). Inter-observer reliability of fatty degeneration grades were excellent to substantial on both pre- and postoperative CTA in supraspinatus (0.8685 and 0.8535) and subscapularis muscles (0.7777 and 0.7972), but fair in infraspinatus/teres minor muscles (0.5791 and 0.5740); however, quantitative Hounsfield units measurements showed excellent reliability for all muscles (ICC: 0.7950 and 0.9346 for SST, 0.7922 and 0.8492 for SSC, and 0.9254 and 0.9052 for IST/TM). No muscle showed improvement of fatty degeneration after surgical repair on qualitative and quantitative assessments; there was no difference in changes of fatty degeneration after surgical repair according to preoperative tear size and post-operative cuff integrity (p > 0.05). The average dose-length product (DLP, mGy . cm) was 365.2 mGy . cm (range, 323.8-417.2 mGy . cm) and estimated average effective dose was 5.1 mSv. Goutallier grades

  5. Coronary plaque property evaluation by coronary CTA and its correlation with inflammatory molecules and MMPs/TIMPs

    Directory of Open Access Journals (Sweden)

    Wen-Bing Yang

    2017-11-01

    Full Text Available Objective: To study the evaluation value of coronary CTA for coronary plaque properties and its correlation with inflammatory molecules and MMPs/TIMPs. Methods: Patients who were diagnosed with acute coronary syndrome in Renmin Hospital of Wuhan University between August 2014 and December 2016 were selected as the ACS group of the research, patients who were diagnosed with stable angina pectoris were selected as the SAP group of the research, and healthy subjects who received physical examination during the same period were selected as the control group of the research. Coronary CTA was done to determine the coronary plaque properties of ACS group, and serum was collected from the three groups of subjects to determine the contents of inflammatory molecules and MMPs/TIMPs collagen metabolites. Results: Serum MIP-1α, MCP-1, sFGL-2, sCD14, CXCL5, I-CTP, III-CTP and EMMPRIN contents of ACS group and SAP group were higher than those of control group while TIMP1, TIMP2 contents were lower than those of control group; serum MIP-1α, MCP-1, sFGL-2, sCD14, CXCL5, I-CTP, III-CTP and EMMPRIN contents of ACS group were higher than those of SAP group while TIMP1 and TIMP2 contents were lower than those of SAP group. Serum MIP-1α, MCP-1, sFGL-2, sCD14, CXCL5, I-CTP, III-CTP and EMMPRIN contents of ACS patients with soft plaque and fibrous plaque were higher than those of ACS patients with calcified plaque while TIMP1 and TIMP2 contents were lower than those of ACS patients with calcified plaque; serum MIP-1α, MCP-1, sFGL-2, sCD14, CXCL5, I-CTP, III-CTP and EMMPRIN contents of ACS patients with soft plaque were higher than those of ACS patients with fibrous plaque while TIMP1, TIMP2 contents were lower than those of ACS patients with fibrous plaque. Conclusion: The coronary plaque property evaluation by coronary CTA is closely related to the changes of inflammatory response and MMPs/TIMPs collagen metabolism.

  6. Low Bone Density

    Science.gov (United States)

    ... Density Exam/Testing › Low Bone Density Low Bone Density Low bone density is when your bone density ... people with normal bone density. Detecting Low Bone Density A bone density test will determine whether you ...

  7. Evaluation and quality control of digital subtraction angiography systems

    International Nuclear Information System (INIS)

    Louisot, P.

    1986-04-01

    After reviewing the development of systems used in angiography, we rewind the medical interest and describe the steps of an angiographic examination. The following chapter is dedicated to the techniques used for the digitalization of video images. The components of the system involved in the image acquisition are thoroughly investigated in chapter 4. Then, we analyse the capabilities of the machines available in France in 1985. Chapter 6 is devoted to the criteria of quality in digital imaging. In order to assign qualitative values to the above criteria, we design a control procedure which is described in chapter 7. The procedure thus allows the estimate of the physical performances of angiographic digital subtraction systems [fr

  8. Digital subtraction angiography with an Isocon camera system: clinical applications

    International Nuclear Information System (INIS)

    Barbaric, Z.L.; Gomes, A.S.; Deckard, M.E.; Nelson, R.S.; Moler, C.L.

    1984-01-01

    A new imaging system for digital subtraction angiography (DSA) was evaluated in 30 clinical studies. The image receptor is a 25 X 25 cm, 12 par gadolinium oxysulfate rare-earth screen whose light output is focused to a low-light-level Isocon camera. The video signal is digitized and processed by an image-array processor containing 31 512 X 512 memories 8 bits deep. In most patients, intraarterial DSA studies were done in conjunction with conventional arteriography. In these arterial studies, images adequate to make a specific diagnosis were obtained using half the radiation dose and half the amount of contrast material needed for conventional angiography. In eight intravenous studies performed either to identify renal artery stenosis or for evaluation of congenital heart anomalies, the images were diagnostic but objectionably noisy

  9. Real-time digital x-ray subtraction imaging

    International Nuclear Information System (INIS)

    Mistretta, C.A.

    1982-01-01

    The invention provides a method of producing visible difference images derived from an X-ray image of an anatomical subject, comprising the steps of directing X-rays through the anatomical subject for producing an image, converting the image into television fields comprising trains of on-going video signals, digitally storing and integrating the on-going video signals over a time interval corresponding to several successive television fields and thereby producing stored and integrated video signals, recovering the video signals from storage and producing integrated video signals, producing video difference signals by performing a subtraction between the integrated video signals and the on-going video signals outside the time interval, and converting the difference signals into visible television difference images representing on-going changes in the X-ray image

  10. Method and apparatus for performing digital intravenous subtraction angiography

    International Nuclear Information System (INIS)

    Stein, J.A.

    1986-01-01

    This invention relates to digital intravenous subtraction angiography (DISA), and more particularly concerns novel apparatus and techniques for providing high resolution angiograms with equipment that coacts with existing standard medical X-ray equipment. A typical medical X-ray generator provides low mA, continuous X-ray exposures illuminating a standard image intensifier producing an image scanned by a conventional television camera to produce a video signal. An analog-to-digital converter digitizes the signal, and adding means adds the digital frame signals together in real time to provide an intermediate digital signal representing the addition of 5 to 20 frames. Digital storage means store the intermediate image signals. Preferably there are two system memories with means for summing a subsequent intermediate image in the second memory while a previously-formed intermediate image is being transferred to disk storage

  11. Real-time digital X-ray subtraction imaging

    International Nuclear Information System (INIS)

    Mistretta, C.A.; Kruger, R.A.; Houk, T.L.

    1979-01-01

    A diagnostic anatomical X-ray apparatus comprising a converter and a television camera for converting an X-ray image of a subject into a series of television fields of video signals is described in detail. A digital memory system stores and integrates the video signals over a time interval corresponding to a plurality of successive television fields. The integrated video signals are recovered from storage and fed to a digital or analogue subtractor, the resulting output being displayed on a television monitor. Thus the display represents on-going changes in the anatomical X-ray image. In a modification, successive groups of fields are stored and integrated in three memories, cyclically, and subtractions are performed between successive pieces of integrated signals to provide a display of successive alterations in the X-ray image. For investigations of the heart, the integrating interval should be of the order of one cardiac cycle. (author)

  12. Double-nuclide subtraction scintiscanning of the pancreas

    International Nuclear Information System (INIS)

    Streithoff, E.C.

    1978-01-01

    The paper intends to find out if there is a correlation between clinical pancreas diagnoses and diagnoses by subtraction scintiscanning; furthermore, the findings of scintiscanning are compared with those of radiological and sonographic methods. In order to get a picture of the efficiency of the methods applied, not only their accuracy is determined but also their validity sum and validity product. The best results are achieved here with angiography, ERCP, and sonography. In the case of pancreatic scintiscanning, an optimal result well above the international standard is only obtained for sensitivity. On the basis of these results, the indications for an optimal and useful application of pancreatic scintiscanning are determined. (orig./AJ) [de

  13. Background subtraction system for pulsed neutron logging of earth boreholes

    International Nuclear Information System (INIS)

    Hopkinson, E.C.

    1977-01-01

    A neutron generator in well logging instrument is pulsed 100 times having a time between pulses of 1400 microseconds. This is followed by an off period of four cycles wherein 2800 microseconds is allowed for capture radiation to decay to an insignificant level and the remaining 2800 microseconds is used to measure background radiation. This results in the neutron source being disabled four pulses after every hundred pulses of operation, or approximately a 4 percent loss of neutron output. A first detector gate is open from 400 to 680 microseconds and a second detector gate is open from 700 to 980 microseconds. During the 100 cycles, each of the gates is thus open for 280 microseconds times 100 for a total of 28,000 microseconds. By scaling the gate count rate by a factor of 10, the background is subtracted directly

  14. Multinuclide digital subtraction imaging in symptomatic prostnetic joints

    International Nuclear Information System (INIS)

    Chafetz, N.; Hattner, R.S.; Ruarke, W.C.; Helms, C.A.; Genant, H.K.; Murray, W.R.

    1985-01-01

    One hundred eleven patients with symptomatic prosthetic joints (86 hips, 23 knees, and two shoulders) were evaluated for prosthetic loosening and infection by combined technetium-99m-MDP/gallium-67 digital subtraction imaging. Clinical correlation was based on the assessment of loosening and bacterial cultures obtained at the time of surgery in 54 patients, joint aspiration cultures obtained in 37 patients, and long-term clinical follow-up for greater than 1.5 years in an additional 15 patients. Results revealed an 80-90% predictive value of a positive test for loosening, and a 95% predictive value of a negative test for infection. However, because of the low sensitivities and specificities observed, this approach to the evaluation of symptomatic prosthetic joints does not seem cost effective

  15. Thallium-technetium-subtraction scintigraphy in secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Adalet, I.; Hawkins, T.; Clark, F.; Wilkinson, R.

    1994-01-01

    Between 1983 and 1992 thallium-technetium subtraction scintigraphy (TTS) was performed on 74 patients with clinical and biochemical evidence of hyperparathyroidism. Twenty-five of the 53 investigations since 1988 were conducted on patients with renal failure with a suspicion of secondary hyperparathyroidism. In a retrospective study we have evaluated radioisotope scintigraphy for patients with adenoma and for renal failure patients with possible parathyroid hyperplasia. Thirty of 74 patients underwent neck exploration. Scintigraphy detected 17 of 24 parathyroid adenomas (sensitivity 71%). In contrast, in six renal patients who came to operation, scintigraphy localised only 5 of 20 hyperplastic parathyroid glands (sensitivity 25%) and in one renal patient we localised a parathyroid adenoma. A review of the literature shows low detection rates for hyperplasia by TTS to be a common observation. Based on these findings a rational approach is offered for parathyroid localisation in renal patients prior to neck exploration. (orig.)

  16. Evaluation of left ventricular function by digital subtraction angiography

    International Nuclear Information System (INIS)

    Kuribayashi, Sachio; Ootaki, Makoto; Matsuyama, Seiya; Kanemoto, Nariaki; Furuya, Hideo

    1985-01-01

    Effects of contrast medium doses on left ventriculographic images using intravenous digital subtraction angiography (IVDSA-LVG) were assessed. The validity of IVDSA-LVG in evaluating ejection fraction (FF) and left ventricular regional wall motion was determined by comparison with conventional left ventriculography using direct injection (direct LVG). The advantages of left ventriculography using intraarterial subtraction angiography (IADSA-LVG) performed by injecting small doses of contrast media directly into the left ventricle were stressed. 1. To assess the effects of doses of contrast media on IVDSA-LVG, 10, 20, and 30 ml Urografin-76 were injected into the superior vena cava in 16 patients, and the resulting images were compared in each patient. With only 10 ml contrast medium, left ventricular opacification was fairly good, and regional wall motion was evaluated in many cases, but 30 ml were needed to calculate ventricular volume and EF. 2. To determine the validity of IVDSA-LVG in evaluating EF and regional wall motion, we compared IVDSA-LVG using 30 ml of contrast medium with direct LVG in 18 patients. There was a good correlation between the two methods in determining EF (r = 0.877), and 90 % of the interpretations of regional wall motion were in agreement by the two methods. IVDSA-LVG was useful and accurate in evaluating EF and regional wall motion of the left ventricle. 3. IADSA-LVG was performed for five patients, and good quality images were obtained in many cases, even with relatively small doses (10 ml) of contrast media. These results suggested that this method may be used in cases with impaired LV function, to avoid hemodynamic derangement induced by conventional direct LVG using large doses of contrast medium. (author)

  17. Three-dimensional bone-free computed tomographic angiography of aneurysms near the skull base using a new bone-removal application

    International Nuclear Information System (INIS)

    Tomura, Noriaki; Otani, Takahiro; Sakuma, Ikuo; Takahashi, Satoshi; Nishii, Toshiaki; Watarai, Jiro

    2009-01-01

    Bone elimination is needed for computed tomography angiography (CTA) because bone structures obscure aneurysms located at the skull base. The purpose of our study was to evaluate the efficacy of three-dimensional (3D)-CTA using an application for bone elimination. A total of 27 patients with 32 angiographically confirmed aneurysms near the skull base were investigated. The 3D maximum intensity projection (MIP) images were initially obtained using the application. Further postprocessing was performed to obtain the MIP and volume-rendered (VR) images. The quality of the initial MIP images by the application was analyzed. Visualization of aneurysms after further processing was also reviewed. The initial MIP images by the application showed almost bone-free images in 23 of the 27 patients. In 8 patients, the image of the internal carotid artery (ICA) was segmentally removed in the initial MIP images by the application. Further postprocessing was able to recover all loss of the ICA image in these eight patients. For visualizing aneurysms and their necks, VR images with the application were significantly superior to VR images without the application. The application for bone elimination allows fast, selective elimination of bony structures and can improve the interpretation of aneurysms near the skull base. (author)

  18. Preparation and certification of the Polish reference material 'Oriental Tobacco Leaves' (CTA-OTL-1) for inorganic trace analysis

    International Nuclear Information System (INIS)

    Dybczynski, R.; Polkowska-Motrenko, H.; Samczynski, Z.; Szopa, Z.

    1996-01-01

    A new Polish certified reference material 'Oriental Tobacco Leaves' (CTA-OTL-1) for inorganic trace analysis was prepared. Fresh tobacco leaves of variety 'Oriental' were dried, ground and sieved. All precautions were taken to avoid contamination of material with metals. The next step was homogenization. Preliminary homogeneity checking consisted in determining of Ca, Fe and K content by X-ray fluorescence. Final homogeneity testing was performed by neutron activation analysis determining Co, Cr, Fe and Rb. To assure long-term stability, the whole lot of material was sterilized by electron beam radiation. Certification of the candidate reference material was done on the basis of world-wide interlaboratory comparisons exercise in which 61 laboratories, using various analytical methods participated. (author). 30 refs, 12 tabs, 21 figs

  19. Preparation and certification of the Polish reference material `Oriental Tobacco Leaves` (CTA-OTL-1) for inorganic trace analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dybczynski, R.; Polkowska-Motrenko, H.; Samczynski, Z.; Szopa, Z. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1996-12-31

    A new Polish certified reference material `Oriental Tobacco Leaves` (CTA-OTL-1) for inorganic trace analysis was prepared. Fresh tobacco leaves of variety `Oriental` were dried, ground and sieved. All precautions were taken to avoid contamination of material with metals. The next step was homogenization. Preliminary homogeneity checking consisted in determining of Ca, Fe and K content by X-ray fluorescence. Final homogeneity testing was performed by neutron activation analysis determining Co, Cr, Fe and Rb. To assure long-term stability, the whole lot of material was sterilized by electron beam radiation. Certification of the candidate reference material was done on the basis of world-wide interlaboratory comparisons exercise in which 61 laboratories, using various analytical methods participated. (author). 30 refs, 12 tabs, 21 figs.

  20. The Fermi Gamma Ray Space Telescope discovers the Pulsar in the Young Galactic Supernova-Remnant CTA 1

    Energy Technology Data Exchange (ETDEWEB)

    Abdo, Aous A.; Ackermann, M.; Atwood, W.B.; Baldini, L.; Ballet, J.; Barbiellini, G.; Baring, M.G.; Bastieri, Denis; Baughman, B.M.; Bechtol, K.; Bellazzini, R.; Berenji, B.; Blandford, R.D.; Bloom, Elliott D.; Bogaert, G.; Bonamente, E.; Borgland, A.W.; Bregeon, J.; Brez, A.; Brigida, M.; Bruel, P.

    2009-05-15

    Energetic young pulsars and expanding blast waves (supernova remnants, SNRs) are the most visible remains after massive stars, ending their lives, explode in core-collapse supernovae. The Fermi Gamma-Ray Space Telescope has unveiled a radio quiet pulsar located near the center of the compact synchrotron nebula inside the supernova remnant CTA 1. The pulsar, discovered through its gamma-ray pulsations, has a period of 316.86 ms, a period derivative of 3.614 x 10{sup -13} s s{sup -1}. Its characteristic age of 10{sup 4} years is comparable to that estimated for the SNR. It is conjectured that most unidentified Galactic gamma ray sources associated with star-forming regions and SNRs are such young pulsars.

  1. The Fermi Gamma Ray Space Telescope discovers the Pulsar in the Young Galactic Supernova-Remnant CTA 1

    International Nuclear Information System (INIS)

    Abdo, Aous A.; Ackermann, M.; Atwood, W.B.; Baldini, L.; Ballet, J.; Barbiellini, G.; Baring, M.G.; Bastieri, Denis; Baughman, B.M.; Bechtol, K.; Bellazzini, R.; Berenji, B.; Blandford, R.D.; Bloom, Elliott D.; Bogaert, G.; Bonamente, E.; Borgland, A.W.; Bregeon, J.; Brez, A.; Brigida, M.; Bruel, P.

    2009-01-01

    Energetic young pulsars and expanding blast waves (supernova remnants, SNRs) are the most visible remains after massive stars, ending their lives, explode in core-collapse supernovae. The Fermi Gamma-Ray Space Telescope has unveiled a radio quiet pulsar located near the center of the compact synchrotron nebula inside the supernova remnant CTA 1. The pulsar, discovered through its gamma-ray pulsations, has a period of 316.86 ms, a period derivative of 3.614 x 10 -13 s s -1 . Its characteristic age of 10 4 years is comparable to that estimated for the SNR. It is conjectured that most unidentified Galactic gamma ray sources associated with star-forming regions and SNRs are such young pulsars

  2. CTA/V detection of bilateral sigmoid sinus dehiscence and suspected idiopathic intracranial hypertension in unilateral pulsatile tinnitus

    International Nuclear Information System (INIS)

    Xu, Shuaishuai; Xu, Jianrong; Ruan, Shidong; Liu, Shanfeng; Gong, Ruozhen

    2018-01-01

    This aimed to evaluate the prevalence and extent of bilateral sigmoid sinus dehiscence (SSD) and to explore the presence of idiopathic intracranial hypertension (IIH) in patients with unilateral pulsatile tinnitus (PT) with CTA/V. Sixty PT patients (52 females; 40.4 ± 11.6 years [20-72]) who underwent CTA/V and 30 non-PT patients (27 females; 38.4 ± 14.7 years [12-62]) were enrolled in this study. The primary outcome measure was the radiographic presence of SSD. The index of transverse sinus stenosis (ITSS) was obtained by multiplying the stenosis scale values for each transverse sinus, and once was ≥ 4, the presence of IIH was suspected. The prevalence and extent of SSD on symptomatic side (78%; maximum transverse diameter, MTD 0.49 ± 0.23; maximum vertical diameter, MVD 0.50 ± 0.26 cm) were significantly higher and larger than those on asymptomatic side (50%, P < 0.001; MTD 0.35 ± 0.18, P = 0.006; MVD 0.30 ± 0.15 cm, P < 0.001) in the study group and those (20%, P < 0.001; MTD 0.36 ± 0.18, P = 0.073; MVD 0.30 ± 0.22 cm, P < 0.048) in the control group. The presence of SSD showed significant correlation with both PT (logistic regression analysis, OR 4.167 [1.450-11.97]; P = 0.008) and suspected IIH (OR 16.25 [1.893-139.5]; P = 0.011). In PT patients, SSD has a significant correlation with PT and a potential correlation with IIH. (orig.)

  3. A subtraction scheme for computing QCD jet cross sections at NNLO. Integrating the iterated singly-unresolved subtraction terms

    Energy Technology Data Exchange (ETDEWEB)

    Bolzoni, Paolo [Hamburg Univ. (Germany). II. Inst. fuer Theoretische Physik; Somogyi, Gabor [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Trocsanyi, Zoltan [Debrecen Univ. (Hungary); Hungarian Academy of Sciences, Debrecen (Hungary). Inst. of Nuclear Research

    2010-11-15

    We perform the integration of all iterated singly-unresolved subtraction terms over the two-particle factorized phase space. We also sum over the unresolved parton flavours. The final result can be written as a convolution (in colour space) of the Born cross section and an insertion operator. We spell out the insertion operator in terms of 24 basic integrals that are defined explicitly. We compute the coefficients of the Laurent-expansion of these integrals in two different ways, with the method of Mellin-Barnes representations and sector decomposition. Finally, we present the Laurentexpansion of the full insertion operator for the specific examples of electron-positron annihilation into two and three jets. (orig.)

  4. A subtraction scheme for computing QCD jet cross sections at NNLO: integrating the iterated singly-unresolved subtraction terms

    Science.gov (United States)

    Bolzoni, Paolo; Somogyi, Gábor; Trócsányi, Zoltán

    2011-01-01

    We perform the integration of all iterated singly-unresolved subtraction terms, as defined in ref. [1], over the two-particle factorized phase space. We also sum over the unresolved parton flavours. The final result can be written as a convolution (in colour space) of the Born cross section and an insertion operator. We spell out the insertion operator in terms of 24 basic integrals that are defined explicitly. We compute the coefficients of the Laurent expansion of these integrals in two different ways, with the method of Mellin-Barnes representations and sector decomposition. Finally, we present the Laurent-expansion of the full insertion operator for the specific examples of electron-positron annihilation into two and three jets.

  5. A new registration method with voxel-matching technique for temporal subtraction images

    Science.gov (United States)

    Itai, Yoshinori; Kim, Hyoungseop; Ishikawa, Seiji; Katsuragawa, Shigehiko; Doi, Kunio

    2008-03-01

    A temporal subtraction image, which is obtained by subtraction of a previous image from a current one, can be used for enhancing interval changes on medical images by removing most of normal structures. One of the important problems in temporal subtraction is that subtraction images commonly include artifacts created by slight differences in the size, shape, and/or location of anatomical structures. In this paper, we developed a new registration method with voxel-matching technique for substantially removing the subtraction artifacts on the temporal subtraction image obtained from multiple-detector computed tomography (MDCT). With this technique, the voxel value in a warped (or non-warped) previous image is replaced by a voxel value within a kernel, such as a small cube centered at a given location, which would be closest (identical or nearly equal) to the voxel value in the corresponding location in the current image. Our new method was examined on 16 clinical cases with MDCT images. Preliminary results indicated that interval changes on the subtraction images were enhanced considerably, with a substantial reduction of misregistration artifacts. The temporal subtraction images obtained by use of the voxel-matching technique would be very useful for radiologists in the detection of interval changes on MDCT images.

  6. Mental Computation or Standard Algorithm? Children's Strategy Choices on Multi-Digit Subtractions

    Science.gov (United States)

    Torbeyns, Joke; Verschaffel, Lieven

    2016-01-01

    This study analyzed children's use of mental computation strategies and the standard algorithm on multi-digit subtractions. Fifty-eight Flemish 4th graders of varying mathematical achievement level were individually offered subtractions that either stimulated the use of mental computation strategies or the standard algorithm in one choice and two…

  7. The Use of Procedural Knowledge in Simple Addition and Subtraction Problems

    Science.gov (United States)

    Fayol, Michel; Thevenot, Catherine

    2012-01-01

    In a first experiment, adults were asked to solve one-digit additions, subtractions and multiplications. When the sign appeared 150 ms before the operands, addition and subtraction were solved faster than when the sign and the operands appeared simultaneously on screen. This priming effect was not observed for multiplication problems. A second…

  8. Subtraction with hadronic initial states at NLO: an NNLO-compatible scheme

    Science.gov (United States)

    Somogyi, Gábor

    2009-05-01

    We present an NNLO-compatible subtraction scheme for computing QCD jet cross sections of hadron-initiated processes at NLO accuracy. The scheme is constructed specifically with those complications in mind, that emerge when extending the subtraction algorithm to next-to-next-to-leading order. It is therefore possible to embed the present scheme in a full NNLO computation without any modifications.

  9. Subtraction with hadronic initial states at NLO: an NNLO-compatible scheme

    International Nuclear Information System (INIS)

    Somogyi, Gabor

    2009-01-01

    We present an NNLO-compatible subtraction scheme for computing QCD jet cross sections of hadron-initiated processes at NLO accuracy. The scheme is constructed specifically with those complications in mind, that emerge when extending the subtraction algorithm to next-to-next-to-leading order. It is therefore possible to embed the present scheme in a full NNLO computation without any modifications.

  10. The digital subtraction technique in lateral urethrocystography. Die laterale Urethrozystographie in digitaler Subtraktionstechnik

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, K. (Radiologische Abt., Caritas-Krankenhaus, Bad Mergentheim (Germany)); Peterseim, H. (Frauenklinik, Caritas-Krankenhaus, Bad Mergentheim (Germany)); Grehn, S. (Radiologische Abt., Caritas-Krankenhaus, Bad Mergentheim (Germany))

    1994-09-01

    The first application of the digital subtraction technique to lateral urethrocystography is described. This methodology facilitates gynecological-urological operations by providing reliable investigation results and an unambiguous image interpretation. Methods and first experiences with the digital subtraction technique in gynecological-urological diagnosis are reported. (orig.)

  11. Bone tumors

    International Nuclear Information System (INIS)

    Moylan, D.J.; Yelovich, R.M.

    1991-01-01

    Primary bone malignancies are relatively rare with less than 4,000 new cases per year. Multiple myeloma (more correctly a hematologic malignancy) accounts for 40%; osteosarcomas, 28%; chondrosarcomas, 13%; fibrosarcomas arising in bone, 4%; and Ewing's sarcoma, 7%. The authors discuss various treatments for bone tumors, including radiotherapy, chemotherapy and surgery

  12. Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Eun Jung; Cho, Ihn Ho [Yeungnam University Hospital, Daegu (Korea, Republic of); Kang, Won Jun [Yonsei University Hospital, Seoul (Korea, Republic of); Kim, Seong Min [Chungnam National University Medical School and Hospital, Daejeon (Korea, Republic of); Won, Kyoung Sook [Keomyung University Dongsan Hospital, Daegu (Korea, Republic of); Lim, Seok Tae [Chonbuk National University Medical School and Hospital, Jeonju (Korea, Republic of); Hwang, Kyung Hoon [Gachon University Gil Hospital, Incheon (Korea, Republic of); Lee, Byeong Il; Bom, Hee Seung [Chonnam National University Medical School and Hospital, Gwangju (Korea, Republic of)

    2009-12-15

    Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Forty-eight patients (M:F=26:22, Age: 63.3{+-}10.4 years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

  13. Effects of automatic tube potential selection on radiation dose index, image quality, and lesion detectability in pediatric abdominopelvic CT and CTA: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Brinkley, Michael F.; Choudhury, Kingshuk Roy; Frush, Donald P. [Duke University School of Medicine, Department of Radiology, DUMC Box 3808, Durham, NC (United States); Ramirez-Giraldo, Juan C. [Siemens Healthcare, Malvern (United States); Samei, Ehsan; Wilson, Joshua M.; Christianson, Olav I. [Duke University School of Medicine, Clinical Imaging Physics Group, Department of Radiology, Durham, NC (United States); Frush, Daniel J. [Duke University School of Medicine, Medical Physics, Durham, NC (United States)

    2016-01-15

    To assess the effect of automatic tube potential selection (ATPS) on radiation dose, image quality, and lesion detectability in paediatric abdominopelvic CT and CT angiography (CTA). A paediatric modular phantom with contrast inserts was examined with routine pitch (1.4) and high pitch (3.0) using a standard abdominopelvic protocol with fixed 120 kVp, and ATPS with variable kVp in non-contrast, contrast-enhanced, and CTA mode. The volume CT dose index (CTDI{sub vol}), contrast-to-noise ratio (CNR) and lesion detectability index (d') were compared between the standard protocol and ATPS examinations. CTDI{sub vol} was reduced in all routine pitch ATPS examinations, with dose reductions of 27-52 % in CTA mode (P < 0.0001), 15-33 % in contrast-enhanced mode (P = 0.0003) and 8-14 % in non-contrast mode (P = 0.03). Iodine and soft tissue insert CNR and d' were improved or maintained in all ATPS examinations. kVp and dose were reduced in 25 % of high pitch ATPS examinations and in none of the full phantom examinations obtained after a single full phantom localizer. ATPS reduces radiation dose while maintaining image quality and lesion detectability in routine pitch paediatric abdominopelvic CT and CTA, but technical factors such as pitch and imaging range must be considered to optimize ATPS benefits. (orig.)

  14. Evaluation of a multi-atlas based method for segmentation of cardiac CTA data: a large-scale, multicenter, and multivendor study

    International Nuclear Information System (INIS)

    Kirisli, H. A.; Schaap, M.; Klein, S.; Papadopoulou, S. L.; Bonardi, M.; Chen, C. H.; Weustink, A. C.; Mollet, N. R.; Vonken, E. J.; Geest, R. J. van der; Walsum, T. van; Niessen, W. J.

    2010-01-01

    Purpose: Computed tomography angiography (CTA) is increasingly used for the diagnosis of coronary artery disease (CAD). However, CTA is not commonly used for the assessment of ventricular and atrial function, although functional information extracted from CTA data is expected to improve the diagnostic value of the examination. In clinical practice, the extraction of ventricular and atrial functional information, such as stroke volume and ejection fraction, requires accurate delineation of cardiac chambers. In this paper, we investigated the accuracy and robustness of cardiac chamber delineation using a multiatlas based segmentation method on multicenter and multivendor CTA data. Methods: A fully automatic multiatlas based method for segmenting the whole heart (i.e., the outer surface of the pericardium) and cardiac chambers from CTA data is presented and evaluated. In the segmentation approach, eight atlas images are registered to a new patient's CTA scan. The eight corresponding manually labeled images are then propagated and combined using a per voxel majority voting procedure, to obtain a cardiac segmentation. Results: The method was evaluated on a multicenter/multivendor database, consisting of (1) a set of 1380 Siemens scans from 795 patients and (2) a set of 60 multivendor scans (Siemens, Philips, and GE) from different patients, acquired in six different institutions worldwide. A leave-one-out 3D quantitative validation was carried out on the eight atlas images; we obtained a mean surface-to-surface error of 0.94±1.12 mm and an average Dice coefficient of 0.93 was achieved. A 2D quantitative evaluation was performed on the 60 multivendor data sets. Here, we observed a mean surface-to-surface error of 1.26±1.25 mm and an average Dice coefficient of 0.91 was achieved. In addition to this quantitative evaluation, a large-scale 2D and 3D qualitative evaluation was performed on 1380 and 140 images, respectively. Experts evaluated that 49% of the 1380 images

  15. Incidence of ischemic lesions in diffusion-weighted imaging after transbrachial digital subtraction angiography

    International Nuclear Information System (INIS)

    Aschenbach, R.; Majeed, A.; Eger, C.; Basche, S.; Kerl, J.M.; Vogl, T.J.

    2008-01-01

    Purpose: to evaluate the frequency of ischemia after transbrachial digital subtraction angiography under ambulant conditions using diffusion-weighted imaging. Materials and methods: 200 patients were included in a prospective study design and received transbrachial digital subtraction angiography under ambulant conditions. Before and after digital subtraction angiography, diffusion-weighted imaging of the brain was performed. Results: in our study population no new lesions were found in diffusion-weighted imaging after digital subtraction angiography during the 3-hour window after angiography. One new lesion was found 3 days after angiography as a late onset complication. Therefore, the frequency of neurological complications is at the level of the confidence interval of 0 - 1.5%. Conclusion: the transbrachial approach under ambulant conditions is a safe method for digital subtraction angiography resulting in a low rate of ischemic lesions in diffusion-weighted imaging. (orig.)

  16. A study on the geometric correction for the digital subtraction radiograph

    International Nuclear Information System (INIS)

    Lim, Suk Young; Koh, Kwang Joon

    2001-01-01

    To develop a new subtraction program for registering digital images based on the correspondence of anatomic structures. The digital periapical images were obtained by Digora system with Rinn XCP equipment after translation of 1-16 mm, and rotation of 2-20 at the premolar and molar areas of the human dried mandible. The new subtraction program, NIH Image program and Emago/Advanced program were compared by the peak-signal -to noise ratio (PSNR). The new subtraction program was superior to NIH Images program and Emago/Advanced program up to 16 mm translation and horizontal angulation up to 4. The new subtraction program can be used for subtracting digital periapical images

  17. The study of myocardial ischemic quality with weighted-subtraction-bull's-eye analysis

    International Nuclear Information System (INIS)

    Chen Wuduan; Tian Jiahe; Hou Qingtian

    1993-01-01

    Weighted-Subtraction-Bull's-eye analysis was studied in 33 normal subjects and 58 patients with coronary artery disease after dipyridamole 99m Tc-MIBI myocardial SPECT imaging. Two kinds of Bull's-eye were produced: (1) subtract rest from 1.2 times dipyridamole from 1.2 times rest Bull's-eye; (2) subtract dipyridamole Bull's-eye. The results showed that the weighted-subtraction-Bull's-eye could clearly displayed the location and puality of ischemic myocardium. And also 74% segments showed so called combined ischemic i.e the blood perfusion reduced, increased and sustained simultaneously after dipyridamole. Therefore weighted-subtraction-Bull's-eye analysis had provided a new method for determination of the quality of ischemia

  18. Bone strength estimates relative to vertical ground reaction force discriminates women runners with stress fracture history.

    Science.gov (United States)

    Popp, Kristin L; McDermott, William; Hughes, Julie M; Baxter, Stephanie A; Stovitz, Steven D; Petit, Moira A

    2017-01-01

    To determine differences in bone geometry, estimates of bone strength, muscle size and bone strength relative to load, in women runners with and without a history of stress fracture. We recruited 32 competitive distance runners aged 18-35, with (SFX, n=16) or without (NSFX, n=16) a history of stress fracture for this case-control study. Peripheral quantitative computed tomography (pQCT) was used to assess volumetric bone mineral density (vBMD, mg/mm 3 ), total (ToA) and cortical (CtA) bone areas (mm 2 ), and estimated compressive bone strength (bone strength index; BSI, mg/mm 4 ) at the distal tibia. ToA, CtA, cortical vBMD, and estimated strength (section modulus; Zp, mm 3 and strength strain index; SSIp, mm 3 ) were measured at six cortical sites along the tibia. Mean active peak vertical (pkZ) ground reaction forces (GRFs), assessed from a fatigue run on an instrumented treadmill, were used in conjunction with pQCT measurements to estimate bone strength relative to load (mm 2 /N∗kg -1 ) at all cortical sites. SSIp and Zp were 9-11% lower in the SFX group at mid-shaft of the tibia, while ToA and vBMD did not differ between groups at any measurement site. The SFX group had 11-17% lower bone strength relative to mean pkZ GRFs (phistory of stress fracture. Bone strength relative to load is also lower in this same region suggesting that strength deficits in the middle 1/3 of the tibia and altered gait biomechanics may predispose an individual to stress fracture. Copyright © 2016. Published by Elsevier Inc.

  19. Bone banking.

    Science.gov (United States)

    Howard, W

    1999-04-01

    The use of human organs and tissues for transplantation in Australia has increased significantly over the past 30 years. In 1997, the Australian Coordinating Committee on Organ Registries and Donation (ACCORD) reported a total number of 190 organ donors, 636 corneal donors and 1509 bone donors Australia wide. Of the 1509 bone donations, 143 came from cadaveric sources and 1366 were made by living donors. Bone transplantation is not as widely recognised as solid organ or corneal transplantation. Due to improved technology and surgical skills, the demand for bone transplantation has increased markedly. This Clinical Update will provide an overview of the physiological aspects of bone transplantation and explore bone banking, a key step in the complex and critical process of bone transplantation.

  20. Growing bone assessment made easy at chairside

    Directory of Open Access Journals (Sweden)

    Priyanka Dalvi

    2016-01-01

    Full Text Available Various intraoral radiographic techniques have been utilized to study bone changes following periodontal therapy, for example, digital subtraction radiography, computer-assisted densitometric image analysis, computed tomography (CT, and cone bean CT. This short communication provides an insight about a novel yet simple technique which utilizes a user-friendly software (Adobe Photoshop CS3 and provides the clinician a quick, objective economical tool to assess periodontal regeneration (bone fill radiographically. The use of this software is recommended in any clinical trial, wherein bone is target tissue to be assessed at different time intervals. It can find clinical applications include endodontic periapical cyst therapy, implant, oral and maxillofacial surgery, and orthopedics surgeries. This method is simple, reliable, and reproducible and helps in objective assessment of radiographic changes of the periodontal osseous defects following periodontal therapy.

  1. Image noise reduction algorithm for digital subtraction angiography: clinical results.

    Science.gov (United States)

    Söderman, Michael; Holmin, Staffan; Andersson, Tommy; Palmgren, Charlotta; Babic, Draženko; Hoornaert, Bart

    2013-11-01

    To test the hypothesis that an image noise reduction algorithm designed for digital subtraction angiography (DSA) in interventional neuroradiology enables a reduction in the patient entrance dose by a factor of 4 while maintaining image quality. This clinical prospective study was approved by the local ethics committee, and all 20 adult patients provided informed consent. DSA was performed with the default reference DSA program, a quarter-dose DSA program with modified acquisition parameters (to reduce patient radiation dose exposure), and a real-time noise-reduction algorithm. Two consecutive biplane DSA data sets were acquired in each patient. The dose-area product (DAP) was calculated for each image and compared. A randomized, blinded, offline reading study was conducted to show noninferiority of the quarter-dose image sets. Overall, 40 samples per treatment group were necessary to acquire 80% power, which was calculated by using a one-sided α level of 2.5%. The mean DAP with the quarter-dose program was 25.3% ± 0.8 of that with the reference program. The median overall image quality scores with the reference program were 9, 13, and 12 for readers 1, 2, and 3, respectively. These scores increased slightly to 12, 15, and 12, respectively, with the quarter-dose program imaging chain. In DSA, a change in technique factors combined with a real-time noise-reduction algorithm will reduce the patient entrance dose by 75%, without a loss of image quality. RSNA, 2013

  2. Identification of formaldehyde-responsive genes by suppression subtractive hybridization

    International Nuclear Information System (INIS)

    Lee, Min-Ho; Kim, Young-Ae; Na, Tae-Young; Kim, Sung-Hye; Shin, Young Kee; Lee, Byung-Hoon; Shin, Ho-Sang; Lee, Mi-Ock

    2008-01-01

    Formaldehyde is frequently used in indoor household and occupational environments. Inhalation of formaldehyde invokes an inflammatory response, including a variety of allergic signs and symptoms. Therefore, formaldehyde has been considered as the most prevalent cause of sick building syndrome, which has become a major social problem, especially in developing urban areas. Further formaldehyde is classified as a genotoxicant in the respiratory tract of rats and humans. To better understand the molecular mechanisms involved in formaldehyde intoxication, we sought differentially regulated genes by formaldehyde exposure to Hs 680.Tr human trachea cells, using polymerase chain reaction (PCR)-based suppression subtractive hybridization. We identified 27 different formaldehyde-inducible genes, including those coding for the major histocompatibility complex, class IA, calcyclin, glutathione S-transferase pi, mouse double minute 2 (MDM2), platelet-derived growth factor receptor alpha, and which are known to be associated with cell proliferation and differentiation, immunity and inflammation, and detoxification. Induction of these genes by formaldehyde treatment was confirmed by reverse transcription PCR and western blot analysis. Further, the expression of calcyclin, glutathione S-transferase pi, PDGFRA and MDM2 were significantly induced in the tracheal epithelium of Sprague Dawley rats after formaldehyde inhalation. Our results suggest that the elevated levels of these genes may be associated with the formaldehyde-induced toxicity, and that they deserve evaluation as potential biomarkers for formaldehyde intoxication

  3. Radiation doses to patients from digital subtraction angiography

    International Nuclear Information System (INIS)

    Goni, H.; Tsalafoutas, I. A.; Tzortzis, G.; Pappas, P.; Bouzas, N.; Loulakas, J.; Georgiou, A.; Georgiou, E.; Yakoumakis, E. N.

    2005-01-01

    This investigation determined patient doses during digital subtraction angiography (DSA). Fluoroscopy time, dose-area product (DAP) and entrance surface air kerma (ESAK) were analysed from 263 DSA examinations, classified into seven categories: (1) abdominal aorta, iliac, femoral, popliteal and leg arteries; (2) abdominal aorta and super-selective DSA of renal arteries; (3) combination of (1) and (2); (4) super-selective DSA of common carotid and vertebral arteries, intracranial branches in face and profile projections; (5) super-selective DSA of hepatic, splenic, superior and inferior mesenteric arteries; (6) combination of (1) and (4); and (7) celiac trunk and branches. Median DAP values were 67.7, 92.9, 76.6, 53.6, 105.7, 76.1 and 2.6 Gy cm 2 , respectively. With the exception of one examination, ESAK values were below 2 Gy: the limit for erythema. Compared with published data, DAP values were within the range reported for (1) and (4), slightly larger for (2) and (5), whereas no references were identified for the remaining three categories. (authors)

  4. A case of aortitis syndrome diagnosed by digital subtraction angiography

    International Nuclear Information System (INIS)

    Tamaki, Atsushi; Sakai, Masashi; Yano, Kimio

    1984-01-01

    A 45-year-old female was admitted to our hospital with complaints of anemia, hypertension, and a dull, throbbing pain in the right side of the neck. On physical examination, a pulsating tumor in the right side of the neck and a ''to-and-fro'' murmur at the right 2nd intercostal space were noted. Laboratory tests revealed ESR 90 mm/hour and CRP 5+. Digital subtraction angiography (DSA) showed an aneurysm distal to the narrowing of the right common carotid artery, in addition to winding and narrowing of the right vertebral and the left common carotid arteries. These findings are typical of Type I aortitis syndrome. Aortogram showed aortic regurgitation (AR). Furthermore, we found the presence of HLA Bw52 and a conspicuous increase of tromboxane B 2 . Treatment involving a combination of prednisolone, azathioprine and estriol was effective, resulting in marked improvement of the patient's general condition as well as laboratory test results. In cases of aortitis syndrome combined with an aneurysm of a large artery and AR, direct opacification of the aorta with a catheter is occasionally hazardous and is difficult to perform repeatedly. DSA is useful in such circumstances because it can be performed repeatedly with little risk and it offers an image as clear as these obtained by direct injection of contrast medium in the aorta. (author)

  5. Robotic digital subtraction angiography systems within the hybrid operating room.

    Science.gov (United States)

    Murayama, Yuichi; Irie, Koreaki; Saguchi, Takayuki; Ishibashi, Toshihiro; Ebara, Masaki; Nagashima, Hiroyasu; Isoshima, Akira; Arakawa, Hideki; Takao, Hiroyuki; Ohashi, Hiroki; Joki, Tatsuhiro; Kato, Masataka; Tani, Satoshi; Ikeuchi, Satoshi; Abe, Toshiaki

    2011-05-01

    Fully equipped high-end digital subtraction angiography (DSA) within the operating room (OR) environment has emerged as a new trend in the fields of neurosurgery and vascular surgery. To describe initial clinical experience with a robotic DSA system in the hybrid OR. A newly designed robotic DSA system (Artis zeego; Siemens AG, Forchheim, Germany) was installed in the hybrid OR. The system consists of a multiaxis robotic C arm and surgical OR table. In addition to conventional neuroendovascular procedures, the system was used as an intraoperative imaging tool for various neurosurgical procedures such as aneurysm clipping and spine instrumentation. Five hundred one neurosurgical procedures were successfully conducted in the hybrid OR with the robotic DSA. During surgical procedures such as aneurysm clipping and arteriovenous fistula treatment, intraoperative 2-/3-dimensional angiography and C-arm-based computed tomographic images (DynaCT) were easily performed without moving the OR table. Newly developed virtual navigation software (syngo iGuide; Siemens AG) can be used in frameless navigation and in access to deep-seated intracranial lesions or needle placement. This newly developed robotic DSA system provides safe and precise treatment in the fields of endovascular treatment and neurosurgery.

  6. Intravenous digital subtraction angiography contrast media time-concentration curves

    International Nuclear Information System (INIS)

    Burbank, F.H.; Brody, W.R.

    1985-01-01

    At any specified radiation dose and system signal-to-noise ratio, temporal (masked-mode) intravenous digital subtraction angiography (IV-DSA) image quality is dependent upon the shape of the arterial time-concentration curve produced by the intravenous injection of iodinated contrast media. If contrast media appears in the arterial circulation as a compact bolus and reaches a high peak, images containing low or no iodine (the mask image or images) and high iodine concentration (the enhanced image or images) can be obtained close together in time, maximizing contrast media enhancement and minimizing the potential for spatial movement (misregistration). However, if the contrast media bolus is broad, rising slowly to a low concentration peak, sufficient time may pass for movement to occur and the opacification difference between the mask image and the enhanced image may be too small to visualize vessels of interest. Consequently, knowledge of the rules which govern the formation of time-concentration curves is central to IV-DSA

  7. Evaluation of left ventricular function using digital subtraction angiography

    International Nuclear Information System (INIS)

    Kozuka, Takahiro; Ohta, Mitsushige

    1985-01-01

    To evaluate function of the left ventricle and myocardial perfusion images, digital subtraction angiography (DSA) was performed in 45 patients with ischemic heart disease. Validity of the technique was compared with data obtained from cine left ventriculogram in all patients and 201 T1 myocardial images in 20 patients. End-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) calculated from DSA were correlated closely with those from cine left ventriculogram (r = 0.92, r = 0.94 and r = 0.86, respectively). Regional contractility at the antero-lateral wall of the left ventricle, assessed by DSA, was also correlated well with cine left ventriculogram (r = 0.75). Evaluation of the inferior wall motion showed less correlation in both procedures (r = 0.68). Phase and amplitude analysis with the same technique with radionuclide cardiac angiography was successfully applied in left ventriculogram obtained by DSA. The procedure seems to be helpful for objective evaluation of the left ventricular wall motion. Myocardial perfusion image, obtained with modified Radtke's technique, showed good coincidence with 201 T1 images. Thus, DSA is applicable for evaluation of function of the left ventricle and myocardial perfusion in patients with ischemic heart disease. (author)

  8. Matching the quasiparton distribution in a momentum subtraction scheme

    Science.gov (United States)

    Stewart, Iain W.; Zhao, Yong

    2018-03-01

    The quasiparton distribution is a spatial correlation of quarks or gluons along the z direction in a moving nucleon which enables direct lattice calculations of parton distribution functions. It can be defined with a nonperturbative renormalization in a regularization independent momentum subtraction scheme (RI/MOM), which can then be perturbatively related to the collinear parton distribution in the MS ¯ scheme. Here we carry out a direct matching from the RI/MOM scheme for the quasi-PDF to the MS ¯ PDF, determining the non-singlet quark matching coefficient at next-to-leading order in perturbation theory. We find that the RI/MOM matching coefficient is insensitive to the ultraviolet region of convolution integral, exhibits improved perturbative convergence when converting between the quasi-PDF and PDF, and is consistent with a quasi-PDF that vanishes in the unphysical region as the proton momentum Pz→∞ , unlike other schemes. This direct approach therefore has the potential to improve the accuracy for converting quasidistribution lattice calculations to collinear distributions.

  9. Experience with digital subtraction angiography of cervicocranial region

    International Nuclear Information System (INIS)

    Bohutova, J.; Neuwirth, J.; Kuncova, S.; Lerlova, L.

    1988-01-01

    Digital subtraction angiography (DSA) of the head was performed in 100 patients for mostly neurological indications, less frequently pathological processes in the region of the external carotid artery. The intravenous or intraarterial route was selected according to the condition and age of the patient and clinical diagnosis. In 55% of cases the contrast medium was administered into the ascending aorta, in 13% selectively into the carotid or vertebral arteries. The examination was performed intravenously in 32%, most frequently via inferior vena cava (26%). The visualization of the whole area of the carotid and vertebral arteries from the ramification of the aortal arc up to the periphery requires to make at least 4 to 5 administrations of contrast medium, since simultaneous representation of lateral and AP projection for DSA has not been so far possible and the screen size is small. In intravenous DSA the amount of contrast medium increases up to 200 ml. Instillation into the ascending artery is therefore preferred and half of the amount is thus sufficient. DSA has proved of advantage in the examination of patients with arteriosclerosis, angiomas and arteriovenous malformations, vascularized and avascular expansive processes in intracranial and extracranial localizations. Quality angiograms were obtained in 84%, those still suitable for evaluation in 14% and useless in 2% of cases. (author). 14 figs., 1 tab., 16 refs

  10. Late iodine enhancement computed tomography with image subtraction for assessment of myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, Yuki; Kido, Teruhito; Kurata, Akira; Kouchi, Takanori; Fukuyama, Naoki; Yokoi, Takahiro; Miyagawa, Masao; Mochizuki, Teruhito [Ehime University Graduate School of Medicine, Department of Radiology, Toon City, Ehime (Japan); Uetani, Teruyoshi [Department of Cardiology, Ehime University Graduate School of Medicine, Toon City, Ehime (Japan); Yamashita, Natsumi [National Hospital Organization Shikoku Cancer Center, Department of Clinical Biostatistics, Section of Cancer Prevention and Epidemiology, Clinical Research Center, Matsuyama City, Ehime (Japan)

    2018-03-15

    To evaluate the feasibility of image subtraction in late iodine enhancement CT (LIE-CT) for assessment of myocardial infarction (MI). A comprehensive cardiac CT protocol and late gadolinium enhancement MRI (LGE-MRI) was used to assess coronary artery disease in 27 patients. LIE-CT was performed after stress CT perfusion (CTP) and CT angiography. Subtraction LIE-CT was created by subtracting the mask volume of the left ventricle (LV) cavity from the original LIE-CT using CTP dataset. The %MI volume was quantified as the ratio of LIE to entire LV volume, and transmural extent (TME) of LIE was classified as 0%, 1-24%, 25-49%, 50-74% or 75-100%. These results were compared with LGE-MRI using the Spearman rank test, Bland-Altman method and chi-square test. One hundred twenty-five (29%) of 432 segments were positive on LGE-MRI. Correlation coefficients for original and subtraction LIE-CT to LGE-MRI were 0.79 and 0.85 for %MI volume. Concordances of the 5-point grading scale between original and subtraction LIE-CT with LGE-MRI were 75% and 84% for TME; concordance was significantly improved using the subtraction technique (p <0.05). Subtraction LIE-CT allowed more accurate assessment of MI extent than the original LIE-CT. (orig.)

  11. The optimal dose reduction level using iterative reconstruction with prospective ECG-triggered coronary CTA using 256-slice MDCT

    International Nuclear Information System (INIS)

    Hou, Yang; Xu, Shu; Guo, Wenli; Vembar, Mani; Guo, Qiyong

    2012-01-01

    Aim: To assess the image quality (IQ) of an iterative reconstruction (IR) technique (iDose 4 ) from prospective electrocardiography (ECG)-triggered coronary computed tomography angiography (coronary CTA) on a 256-slice multi-detector CT (MDCT) scanner and determine the optimal dose reduction using IR that can provide IQ comparable to filtered back projection (FBP). Method and materials: 110 consecutive patients (69 men, 41 women; age: 54 ± 10 years) underwent coronary CTA on a 256-slice MDCT (Brilliance iCT, Philips Healthcare). The control group (Group A, n = 21) were scanned using the conventional tube output (120 kVp, 210 mAs) and reconstructed using FBP. The other 4 groups were scanned with the same kVp but successively reduced tube output as follows: B[n = 15]: 125 mAs; C[n = 22]: 105 mAs; D[n = 36]: 84 mAs: E[n = 16]: 65 mAs) and reconstructed using IR levels of L3 (Group B), L4 (Group C) and L5 (Groups D and E), to compensate for the noise increase. All images were reconstructed using the same kernel (XCB). Two radiologists graded IQ in a blinded fashion on a 4-point scale (4 – excellent, 3 – good, 2 – fair and 1 – poor). Quantitative measurements of CT values, image noise and contrast-to-noise (CNR) were measured in each group. A receiver-operating characteristic (ROC) analysis was performed to determine a radiation reduction threshold up to which excellent IQ was maintained. Results: There were no significant differences in objective noise, SNR and CNR values among Groups A, B, C, D, and E (P = 0.14, 0.09, 0.17, respectively). There were no significant differences in the scores of the subjective IQ between Group A, and Groups B, C, D, E (P = 0.23–0.97). Significant differences in image sharpness and study acceptability were observed between groups A and E (P < 0.05). Using the criterion of excellent IQ (score 4), the ROC curve of dose levels and IQ acceptability established a reduction of 60% of tube output (Group D) as optimum cutoff point (AUC

  12. Preliminary study of lateral cerebral angiography with reverse rotation in the digital image registration and subtraction

    International Nuclear Information System (INIS)

    Shen Zhenglin; Liu Dongyang; Shen Zhenghai; Li Shuping; Zhang Ziyan; Wu Yongjuan; Liu Peijun

    2012-01-01

    Objective: Investigate the value and feasibility of image registration with reverse rotation in lateral cerebral DSA. Methods: (1) Experimental study: the target images were subtracted directly, and subtracted again after reverse rotation. Software of registration and subtraction with reverse rotation edited by the author utilizing Visual Basic. The function of the automatic angle detection by the software were evaluated to see whether it detected the angle of line. The subtraction function of DSA by the software was evaluated. (2) Clinical retrospective study: the untreated mask and target images of 15 patients with motion along vertical axis during lateral cerebral DSA were uploaded to the software. The target images were processed with and without the software to get two sets of images. (3) Evaluation: four experienced radiologists read and compared the two sets of the images,and graded their findings. Results: (1) The automatic detection by the software suggested that the target images should be rotated counterclockwise 1.3°. The subtraction result of the software was satisfactory. (2) In the 15 sets of images, there were only three sets of images deemed optimal after traditional subtraction. After reverse rotation, artifacts were significantly reduced and the image sharper. There were ten cases with significant artifacts after traditional subtraction, and those images were sharper and showed more peripheral vessels after reverse rotation. The traditional subtraction images of two sets could not be interpreted,the reverse rotation registration images reached the diagnostic quality. (3) Subjective evaluation: there were more information and less noise and distortion in the registration images with reverse rotation than in the traditional subtraction. But the image resolution decreased slightly after reverse rotation registration. Conclusion: The registration of digital angiography with reverse rotation can improve the image quality in lateral cerebral DSA

  13. The immune complex CTA1-DD/IgG adjuvant specifically targets connective tissue mast cells through FcγRIIIA and augments anti-HPV immunity after nasal immunization.

    Science.gov (United States)

    Fang, Y; Zhang, T; Lidell, L; Xu, X; Lycke, N; Xiang, Z

    2013-11-01

    We have previously reported that CTA1-DD/IgG immune complexes augment antibody responses in a mast cell-dependent manner following intranasal (IN) immunizations. However, from a safety perspective, mast cell activation could preclude clinical use. Therefore, we have extended these studies and demonstrate that CTA1-DD/IgG immune complexes administered IN did not trigger an anaphylactic reaction. Importantly, CTA1-DD/IgE immune complexes did not activate mast cells. Interestingly, only connective tissue, but not mucosal, mast cells could be activated by CTA1-DD/IgG immune complexes. This effect was mediated by FcγRIIIA, only expressed on connective tissue mast cells, and found in the nasal submucosa. FcγRIIIA-deficient mice had compromised responses to immunization adjuvanted by CTA1-DD/IgG. Proof-of-concept studies revealed that IN immunized mice with human papillomavirus (HPV) type 16 L1 virus-like particles (VLP) and CTA1-DD/IgG immune complexes demonstrated strong and sustained specific antibody titers in serum and vaginal secretions. From a mast cell perspective, CTA1-DD/IgG immune complexes appear to be safe and effective mucosal adjuvants.

  14. Digital subtraction arthrography in preoperative evaluation of painful total hip arthroplasty

    International Nuclear Information System (INIS)

    Ginai, A.Z.; Biezen, F.C. van; Kint, P.A.M.; Oei, H.Y.; Hop, W.C.J.

    1996-01-01

    Digital subtraction arthrograms, scintigrams and plain radiographs of 70 consecutive patients who underwent revision hip arthroplasty were scored individually and in masked fashion for the presence or absence of features indicating loosening of femoral and/or acetabular components. The operative findings acted as the gold standard. Digital subtraction arthrography was best for predicting a loose acetabular component, while no significant additional predictive value was found for plain radiographs and scintigraphy. Digital subtraction arthrography was also the most important modality for predicting a loose femoral component, while the plain radiograph was of significant additional value and scintigraphy was of no additional value on multivariate analysis. (orig./MG)

  15. Bone development

    DEFF Research Database (Denmark)

    Tatara, M.R.; Tygesen, Malin Plumhoff; Sawa-Wojtanowicz, B.

    2007-01-01

    The objective of this study was to determine the long-term effect of alpha-ketoglutarate (AKG) administration during early neonatal life on skeletal development and function, with emphasis on bone exposed to regular stress and used to serve for systemic changes monitoring, the rib. Shropshire ram.......01). Furthermore, AKG administration induced significantly higher bone mineral density of the cortical bone by 7.1% (P

  16. Cloud Ablation by a Relativistic Jet and the Extended Flare in CTA 102 in 2016 and 2017

    Science.gov (United States)

    Zacharias, M.; Böttcher, M.; Jankowsky, F.; Lenain, J.-P.; Wagner, S. J.; Wierzcholska, A.

    2017-12-01

    In late 2016 and early 2017, the flat spectrum radio quasar CTA 102 exhibited a very strong and long-lasting outburst. The event can be described by a roughly two-month long increase of the baseline flux in the monitored energy bands (optical to γ-rays) by a factor 8, and a subsequent decrease over another two months back to pre-flare levels. The long-term trend was superseded by short but very strong flares, resulting in a peak flux that was a factor 50 above pre-flare levels in the γ-ray domain and almost a factor 100 above pre-flare levels in the optical domain. In this paper, we explain the long-term evolution of the outburst by the ablation of a gas cloud penetrating the relativistic jet. The slice-by-slice ablation results in a gradual increase of the particle injection until the center of the cloud is reached, after which the injected number of particles decreases again. With reasonable cloud parameters, we obtain excellent fits of the long-term trend.

  17. Comparative study between rib imaging of DR dual energy subtraction technology and chest imaging

    International Nuclear Information System (INIS)

    Yu Jianming; Lei Ziqiao; Kong Xiangchuang

    2006-01-01

    Objective: To investigate the application value of DR dual energy subtraction technology in rib lesions. Methods: 200 patients were performed with chest DR dual energy subtraction, comparing the rib imaging between DR of thorax and chest imaging using ROC analysis. Results: Among the total of 200 patients, there are 50 cases of rib calcification, 7 cases of rib destruction, 22 cases of rib fracture. The calcification, destruction and fracture were displayed respectively by ribs below diaphragm and rib markings. The analytic parameter of rib imaging of DR dual energy subtraction Az is 0.9367, while that of rib imaging of chest Az is 0.6830. Conclusion: DR dual energy subtraction technology is superior to chest imaging in the displaying of rib lesion and ribs below diaphragm. (authors)

  18. Broken bone

    Science.gov (United States)

    ... Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Broken bone URL of this page: //medlineplus.gov/ency/ ... following steps to reduce your risk of a broken bone: Wear protective ... pads. Create a safe home for young children. Place a gate at stairways ...

  19. A multiple regression analysis for accurate background subtraction in 99Tcm-DTPA renography

    International Nuclear Information System (INIS)

    Middleton, G.W.; Thomson, W.H.; Davies, I.H.; Morgan, A.

    1989-01-01

    A technique for accurate background subtraction in 99 Tc m -DTPA renography is described. The technique is based on a multiple regression analysis of the renal curves and separate heart and soft tissue curves which together represent background activity. It is compared, in over 100 renograms, with a previously described linear regression technique. Results show that the method provides accurate background subtraction, even in very poorly functioning kidneys, thus enabling relative renal filtration and excretion to be accurately estimated. (author)

  20. The contribution of chemical shift imaging with digital subtracting images to the diagnosis of steatohepatitis

    International Nuclear Information System (INIS)

    Guo Xinghua; Wang Juanping; Zhang Chongjie; Zheng Guofang; Fan Ruiqiang; Zhu Sumei; Liu Qiwang

    2006-01-01

    Objective: To investigate the diagnosis value of chemical shift imaging with digital subtracting in steatohepatitis. Methods: The in-phase images were subtracted by the out-phase ones in 34 cases of steatohepatitis, and the CNR were measured on these subtracted images to estimate the steatosis of the liver. The relationship of CT grade of steatohepatitis and CNR from the subtracted images was analyzed to evaluate the relationship between CNR and the degree of hepatic steatosis. The sensitivity and specificity of the subtracting and eyeballing methods were compared with chi-square test. Results: On the subtracted images, the liver and spleen were seen nearly the same aspects as low signals, CNR=0.98±0.06, meanwhile the spongy vertebra and the subcutaneous or abdominal lipid were seen as obvious higher signals in 52 normal cases. On the 34 steatohepatitis, scattered high signals were seen in the liver, which made the signal of liver higher than that of spleen, CNR=3.25±0.91--14.35±6.10. There was positive correlation between CNR and CT grade in the 34 cases of steatohepatitis, r=0.893, P<0.01. The sensitivity and specificity of the subtracting method were 88.24% and 94. 23%, significantly higher than that of the eyeballing results, 32.35% and 80.77%, P<0.01 and P<0.05. Conclusion: Chemical shift imaging with digital subtracting is a sensitive, specific, objective method to diagnose steatohepatitis and it is of potential ability for quantitative diagnosis. (authors)

  1. A temporal subtraction method for thoracic CT images based on generalized gradient vector flow

    International Nuclear Information System (INIS)

    Miyake, Noriaki; Kim, H.; Maeda, Shinya; Itai, Yoshinori; Tan, J.K.; Ishikawa, Seiji; Katsuragawa, Shigehiko

    2010-01-01

    A temporal subtraction image, which is obtained by subtraction of a previous image from a current one, can be used for enhancing interval changes (such as formation of new lesions and changes in existing abnormalities) on medical images by removing most of the normal structures. If image registration is incorrect, not only the interval changes but also the normal structures would be appeared as some artifacts on the temporal subtraction image. In a temporal subtraction technique for 2-D X-ray image, the effectiveness is shown through a lot of clinical evaluation experiments, and practical use is advancing. Moreover, the MDCT (Multi-Detector row Computed Tomography) can easily introduced on medical field, the development of a temporal subtraction for thoracic CT Images is expected. In our study, a temporal subtraction technique for thoracic CT Images is developed. As the technique, the vector fields are described by use of GGVF (Generalized Gradient Vector Flow) from the previous and current CT images. Afterwards, VOI (Volume of Interest) are set up on the previous and current CT image pairs. The shift vectors are calculated by using nearest neighbor matching of the vector fields in these VOIs. The search kernel on previous CT image is set up from the obtained shift vector. The previous CT voxel which resemble standard the current voxel is detected by voxel value and vector of the GGVF in the kernel. And, the previous CT image is transformed to the same coordinate of standard voxel. Finally, temporal subtraction image is made by subtraction of a warping image from a current one. To verify the proposal method, the result of application to 7 cases and the effectiveness are described. (author)

  2. Comparison of two interpolative background subtraction methods using phantom and clinical data

    International Nuclear Information System (INIS)

    Houston, A.S.; Sampson, W.F.D.

    1989-01-01

    Two interpolative background subtraction methods used in scintigraphy are tested using both phantom and clinical data. Cauchy integral subtraction was found to be relatively free of artefacts but required more computing time than bilinear interpolation. Both methods may be used with reasonable confidence for the quantification of relative measurements such as left ventricular ejection fraction and myocardial perfusion index but should be avoided if at all possible in the quantification of absolute measurements such as glomerular filtration rate. (author)

  3. Subtractions in the Adler sum rule and violation of charge symmetry

    International Nuclear Information System (INIS)

    Dominguez, C.A.; Moreno, H.; Zepeda, A.

    1976-01-01

    The consequences of a once-subtracted dispersion relation in the derivation of the Adler sum rule are investigated. It is shown that one can expect a breakdown of charge symmetry, of the isotriplet-current hypothesis, and of scaling of the structure functions. These breakdowns are related to the possible presence of a nonzero subtraction function at asymptotic energies and arbitrary q 2 . We also comment about second-class currents and PCAC (partial conservation of axial-vector current) relations

  4. Subtraction of random coincidences in γ-ray spectroscopy: A new approach

    International Nuclear Information System (INIS)

    Pattabiraman, N.S.; Ghugre, S.S.; Basu, S.K.; Garg, U.; Ray, S.; Sinha, A.K.; Zhu, S.

    2006-01-01

    A new analytical method for estimation and subsequent subtraction of random coincidences has been developed. It utilizes the knowledge of the counts in the main diagonal of a background-subtracted symmetric data set for the estimation of the events originating from random coincidences. This procedure has been successfully applied to several data sets. It could be a valuable tool for low-fold data sets, especially for low-cross-section events

  5. Bone densitometry

    DEFF Research Database (Denmark)

    Ravn, Pernille; Alexandersen, P; Møllgaard, A

    1999-01-01

    The bisphosphonates have been introduced as alternatives to hormone replacement therapy (HRT) for the treatment and prevention of postmenopausal osteoporosis. The expected increasing application in at clinical practice demands cost-effective and easily handled methods to monitor the effect on bone....... The weak response at the distal forearm during antiresorptive treatment has restricted the use of bone densitometry at this region. We describe a new model for bone densitometry at the distal forearm, by which the response obtained is comparable to the response in other regions where bone densitometry...... is much more expensive and technically complicated. By computerized iteration of single X-ray absorptiometry forearm scans we defined a region with 65% trabecular bone. The region was analyzed in randomized, double-masked, placebo- controlled trials: a 2-year trial with alendronate (n = 69), a 1-year...

  6. The front-end electronics and slow control of large area SiPM for the SST-1M camera developed for the CTA experiment

    Czech Academy of Sciences Publication Activity Database

    Aguilar, J.A.; Bilnik, W.; Borkowski, J.; Mandát, Dušan; Pech, Miroslav; Schovánek, Petr

    Roč. 830, Sep (2016), s. 219-232 ISSN 0168-9002 R&D Projects: GA MŠk LM2015046; GA MŠk LE13012; GA MŠk LG14019 Institutional support: RVO:68378271 Keywords : CTA * SiPM * G-APD * preamplifier * front-end * slow-control * compensation Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 1.362, year: 2016

  7. The control system of the 12-m medium-size telescope prototype: a test-ground for the CTA array control

    Science.gov (United States)

    Oya, I.; Anguner, E. A.; Behera, B.; Birsin, E.; Fuessling, M.; Lindemann, R.; Melkumyan, D.; Schlenstedt, S.; Schmidt, T.; Schwanke, U.; Sternberger, R.; Wegner, P.; Wiesand, S.

    2014-07-01

    The Cherenkov Telescope Array (CTA) will be the next generation ground-based very-high energy -ray observatory. CTA will consist of two arrays: one in the Northern hemisphere composed of about 20 telescopes, and the other one in the Southern hemisphere composed of about 100 telescopes, both arrays containing telescopes of different sizes and types and in addition numerous auxiliary devices. In order to provide a test-ground for the CTA array control, the steering software of the 12-m medium size telescope (MST) prototype deployed in Berlin has been implemented using the tools and design concepts under consideration to be used for the control of the CTA array. The prototype control system is implemented based on the Atacama Large Millimeter/submillimeter Array (ALMA) Common Software (ACS) control middleware, with components implemented in Java, C++ and Python. The interfacing to the hardware is standardized via the Object Linking and Embedding for Process Control Unified Architecture (OPC UA). In order to access the OPC UA servers from the ACS framework in a common way, a library has been developed that allows to tie the OPC UA server nodes, methods and events to the equivalents in ACS components. The front-end of the archive system is able to identify the deployed components and to perform the sampling of the monitoring points of each component following time and value change triggers according to the selected configurations. The back-end of the archive system of the prototype is composed by two different databases: MySQL and MongoDB. MySQL has been selected as storage of the system configurations, while MongoDB is used to have an efficient storage of device monitoring data, CCD images, logging and alarm information. In this contribution, the details and conclusions on the implementation of the control software of the MST prototype are presented.

  8. On the usefulness of portal monitor unit subtraction in radiation therapy

    International Nuclear Information System (INIS)

    Kuperman, Vadim Y; Lubich, Leslie M

    2003-01-01

    In order to avoid additional dose to patients caused by portal imaging with megavoltage x-rays, portal monitor units (MUs) are frequently subtracted from the actual treatment MUs. This study examines the usefulness of portal MU subtraction in radiation therapy. For 11 prostate cancer patients treated with 23 MV photons, dose to prostate due to portal filming with 6 MV photons was determined. In all 11 patients subtraction of portal MU values from the actual treatment MUs resulted in a small underdosing of the prostate with an average treatment error of -0.5%. Portal filming without MU subtraction would cause small overdosing of the prostate with an average treatment error of 1.2%. The results of this study indicate that the benefits of portal MU subtraction are in doubt if (a) the energy of treatment x-rays is much higher than that of the portal x-rays and/or (b) when radiotherapy is performed with physical wedges. Based on the obtained results, we argue against unconditional use of the portal MU subtraction method to eliminate the dose from portal imaging

  9. Value of blood-pool subtraction in cardiac indium-111-labeled platelet imaging

    Energy Technology Data Exchange (ETDEWEB)

    Machac, J.; Vallabhajosula, S.; Goldman, M.E.; Goldsmith, S.J.; Palestro, C.; Strashun, A.; Vaquer, R.; Phillips, R.A.; Fuster, V. (Mt. Sinai Medical Center, New York, NY (USA))

    1989-09-01

    Blood-pool subtraction has been proposed to enhance {sup 111}In-labeled platelet imaging of intracardiac thrombi. We tested the accuracy of labeled platelet imaging, with and without blood-pool subtraction, in ten subjects with cardiac thrombi of varying age, eight with endocarditis being treated with antimicrobial therapy and ten normal controls. Imaging was performed early after labeled platelet injection (24 hr or less) and late (48 hr or more). Blood-pool subtraction was carried out. All images were graded subjectively by four experienced, blinded readers. Detection accuracy was measured by the sensitivity at three fixed levels of specificity estimated from receiver operator characteristic curve analysis and tested by three-way analysis of variance. Detection accuracy was generally improved on delayed images. Blood-pool subtraction did not improve accuracy. Although blood-pool subtraction increased detection sensitivity, this was offset by decreased specificity. For this population studied, blood-pool subtraction did not improve subjective detection of abnormal platelet deposition by 111In platelet imaging.

  10. Value of blood-pool subtraction in cardiac indium-111-labeled platelet imaging

    International Nuclear Information System (INIS)

    Machac, J.; Vallabhajosula, S.; Goldman, M.E.; Goldsmith, S.J.; Palestro, C.; Strashun, A.; Vaquer, R.; Phillips, R.A.; Fuster, V.

    1989-01-01

    Blood-pool subtraction has been proposed to enhance 111 In-labeled platelet imaging of intracardiac thrombi. We tested the accuracy of labeled platelet imaging, with and without blood-pool subtraction, in ten subjects with cardiac thrombi of varying age, eight with endocarditis being treated with antimicrobial therapy and ten normal controls. Imaging was performed early after labeled platelet injection (24 hr or less) and late (48 hr or more). Blood-pool subtraction was carried out. All images were graded subjectively by four experienced, blinded readers. Detection accuracy was measured by the sensitivity at three fixed levels of specificity estimated from receiver operator characteristic curve analysis and tested by three-way analysis of variance. Detection accuracy was generally improved on delayed images. Blood-pool subtraction did not improve accuracy. Although blood-pool subtraction increased detection sensitivity, this was offset by decreased specificity. For this population studied, blood-pool subtraction did not improve subjective detection of abnormal platelet deposition by 111In platelet imaging

  11. Quantitative analysis of planar technetium-99m-sestamibi myocardial perfusion images using modified background subtraction

    International Nuclear Information System (INIS)

    Koster, K.; Wackers, F.J.; Mattera, J.A.; Fetterman, R.C.

    1990-01-01

    Standard interpolative background subtraction, as used for thallium-201 ( 201 Tl), may create artifacts when applied to planar technetium-99m-Sestamibi ( 99m Tc-Sestamibi) images, apparently because of the oversubtraction of relatively high extra-cardiac activity. A modified background subtraction algorithm was developed and compared to standard background subtraction in 16 patients who had both exercise-delayed 201 Tl and exercise-rest 99m Tc-Sestamibi imaging. Furthermore, a new normal data base was generated. Normal 99m Tc-Sestamibi distribution was slightly different compared to 201 Tl. Using standard background subtraction, mean defect reversibility was significantly underestimated by 99m Tc-Sestamibi compared to 201 Tl (2.8 +/- 4.9 versus -1.8 +/- 8.4, p less than 0.05). Using the modified background subtraction, mean defect reversibility on 201 Tl and 99m Tc-Sestamibi images was comparable (2.8 +/- 4.9 versus 1.7 +/- 5.2, p = NS). We conclude, that for quantification of 99m Tc-Sestamibi images a new normal data base, as well as a modification of the interpolative background subtraction method should be employed to obtain quantitative results comparable to those with 201 Tl

  12. Automated identification of best-quality coronary artery segments from multiple-phase coronary CT angiography (cCTA) for vessel analysis

    Science.gov (United States)

    Zhou, Chuan; Chan, Heang-Ping; Hadjiiski, Lubomir M.; Chughtai, Aamer; Wei, Jun; Kazerooni, Ella A.

    2016-03-01

    We are developing an automated method to identify the best quality segment among the corresponding segments in multiple-phase cCTA. The coronary artery trees are automatically extracted from different cCTA phases using our multi-scale vessel segmentation and tracking method. An automated registration method is then used to align the multiple-phase artery trees. The corresponding coronary artery segments are identified in the registered vessel trees and are straightened by curved planar reformation (CPR). Four features are extracted from each segment in each phase as quality indicators in the original CT volume and the straightened CPR volume. Each quality indicator is used as a voting classifier to vote the corresponding segments. A newly designed weighted voting ensemble (WVE) classifier is finally used to determine the best-quality coronary segment. An observer preference study is conducted with three readers to visually rate the quality of the vessels in 1 to 6 rankings. Six and 10 cCTA cases are used as training and test set in this preliminary study. For the 10 test cases, the agreement between automatically identified best-quality (AI-BQ) segments and radiologist's top 2 rankings is 79.7%, and between AI-BQ and the other two readers are 74.8% and 83.7%, respectively. The results demonstrated that the performance of our automated method was comparable to those of experienced readers for identification of the best-quality coronary segments.

  13. Estimation of center line and diameter of brain blood vessel using three-dimensional blood vessel matching method with head three-dimensional CTA image

    International Nuclear Information System (INIS)

    Maekawa, Masashi; Shinohara, Toshihiro; Nakayama, Masato; Nakasako, Noboru

    2010-01-01

    To support and automate the brain blood vessel disease diagnosis, a novel method to obtain the center line and the diameter of a blood vessel is proposed with a three-dimensional head computed tomographic angiography (CTA) image. Although the line thinning processing with distance transform or gray information is generally used to obtain the blood vessel center line, this method is not essentially one to obtain the center line and tends to yield extra lines depending on CTA images. In this study, the center line of the blood vessel is obtained by tracing the vessel. The blood vessel is traced by sequentially estimating the center point and direction of the blood vessel. The center point and direction of the blood vessel are estimated by taking the correlation between the blood vessel and a solid model of the blood vessel that is designed by considering noise influence. In addition, the vessel diameter is also estimated by correlating the blood vessel and the blood vessel model of which the diameter is variable. The validity of the proposed method is confirmed by experimentally applied the proposed method to an actual three-dimensional head CTA image. (author)

  14. Pedicle subtraction osteotomy in elderly patients with degenerative sagittal imbalance.

    Science.gov (United States)

    Cho, Kyu-Jung; Kim, Ki-Tack; Kim, Whoan-Jeang; Lee, Sang-Hoon; Jung, Jae-Hoon; Kim, Young-Tae; Park, Hae-Bong

    2013-11-15

    Retrospective, radiographical analysis. To evaluate pedicle subtraction osteotomy (PSO) as a means of correcting severe degenerative sagittal imbalance in elderly patients. PSO in patients with degenerative sagittal imbalance is likely to cause more complications than in patients with iatrogenic flatback deformity. This study analyzed 34 patients who underwent fusion to the sacrum, with a minimum 2-year follow-up. Age of the patients were in the range from 58 to 73 with the mean at 65.5 years. PSO was performed at one segment in all cases, consisting of L3 (n = 26), L4 (n = 4), L2 (n = 3), and L1 (n = 1). The average number of levels fused was 8.15. Ten patients had structural interbody fusion at the lumbosacral junction. Applying PSO at one segment, the mean correction of the lordotic angle at the osteotomy site was 33.3°, of which the loss of correction (LOC) was 4.0° at the last visit. The correction of lumbar lordosis was 33.7° and the LOC was 8.5°. The sagittal C7 plumb was 215.9 mm before surgery, corrected to 35.1 mm after surgery, and changed to 95.9 mm by the last visit. The correction of the sagittal C7 plumb was 119.9 mm and the LOC was 60.9 mm. There was substantial LOC in lumbar lordosis and sagittal C7 plumb. In 10 patients with addition of posterior lumbar interbody fusion, the LOC of lumbar lordosis was 7.4°, which was less than 9° in those without it. PSO for the correction of degenerative sagittal imbalance in elderly patients resulted in correction of sagittal alignment with a significant LOC of lumbar lordosis and sagittal C7 plumb. The LOC of lumbar lordosis occurred at both the osteotomy and non-osteotomy site. The addition of anterior column support is helpful to maintain correction and reduce complications. N/A.

  15. Bone healing and bone substitutes.

    Science.gov (United States)

    Costantino, Peter D; Hiltzik, David; Govindaraj, Satish; Moche, Jason

    2002-02-01

    With the advent of new biomaterials and surgical techniques, the reconstructive surgeon has a wider range of treatment modalities for the rehabilitation and reconstruction of craniofacial skeletal deformities than ever before. These innovative substances act as true bone graft substitutes, thereby allowing the surgeon to avoid the use of autogenous bone grafts and their associated donor site morbidity. Surgeons have long been interested in producing a composite graft that can heal faster by induction, incorporate with surrounding tissues, and be remodeled to resemble native bone. Currently, there are a host of bone graft substitutes available that vary in both their composition and properties. Craniomaxillofacial surgeons must therefore become comfortable with numerous biomaterials to best tailor the treatment for each patient individually. Ongoing investigations into the next phase of tissue engineering will continue to bring us closer to the ability to regenerate or replace bone.

  16. In vivo evaluation of the 3-carboranyl thymidine analogue (3-CTA), N5-2OH, for neutron capture therapy

    International Nuclear Information System (INIS)

    Barth, Rolf F.; Yang, Weilian; Wu, Gong; Byun, Youngjoo; Tjarks, Werner; Eriksson, Staffan; Binns, Peter J.; Riley, Kent J.

    2006-01-01

    The purpose of the present study was to evaluate a 3 CTA, designated N5-2OH, as a boron delivery agent for NCT. Target validation was established using the thymidine kinase 1 (+) wild type L929 cell line and its TK1(-) counterpart, which were implanted subcutaneously into NIH nu/nu mice. 10 B-enriched N5-2OH, solubilized in DMSO (50μg 10 B in 15μl), was administered by 2 intratumoral (i.t.) injections at 2 h intervals. Two hours later the animals were irradiated at the MITR-II Research Reactor, following which tumor volumes were determined over a period of 30 days. Mice bearing TK1(+) wild type tumors, which had received N5-2OH, had a 15 fold inhibition in tumor growth compared to TK1(-) controls (247 versus 3,603 mm 3 ). Based on these data, biodistribution and therapy studies were initiated in F98 glioma bearing rats. Animals received 500μg of N5-2OH, administered intracerebrally (i.c.) by convection enhanced delivery (CED) using ALZET pumps (8μl/h for 24 h). The tumor boron concentration was 17.3μg/g compared to undetectable amounts in normal brain and blood. BNCT was carried out 14 d following i.c. implantation of 10 3 F98 glioma cells and 24 h following CED of N5-2OH (500μg/200μl). The mean survival time (MST) of these animals was 38 d compared to 31 d and 25 d, respectively, for irradiated and untreated controls. Studies are planned to optimize the delivery and formulation of N5-2OH and additional therapy studies will be carried out using N5-2OH in combination with BPA and BSH. (author)

  17. Bone Biopsy

    Science.gov (United States)

    ... several inches long with a hollow core to capture the bone specimen. The CT scanner is typically ... IV), ultrasound machine and devices that monitor your heart beat and blood pressure. top of page How ...

  18. Bone pain

    DEFF Research Database (Denmark)

    Frost, Charlotte Ørsted; Hansen, Rikke Rie; Heegaard, Anne-Marie

    2016-01-01

    Skeletal conditions are common causes of chronic pain and there is an unmet medical need for improved treatment options. Bone pain is currently managed with disease modifying agents and/or analgesics depending on the condition. Disease modifying agents affect the underlying pathophysiology...... of the disease and reduce as a secondary effect bone pain. Antiresorptive and anabolic agents, such as bisphosphonates and intermittent parathyroid hormone (1-34), respectively, have proven effective as pain relieving agents. Cathepsin K inhibitors and anti-sclerostin antibodies hold, due to their disease...... modifying effects, promise of a pain relieving effect. NSAIDs and opioids are widely employed in the treatment of bone pain. However, recent preclinical findings demonstrating a unique neuronal innervation of bone tissue and sprouting of sensory nerve fibers open for new treatment possibilities....

  19. Bone sarcomas

    International Nuclear Information System (INIS)

    Mudry, P.

    2008-01-01

    Bone sarcomas are malignancies with peak incidence in adolescents and young adults. The most frequent are osteosarcoma and Ewing sarcoma/PNET, in an older adults are seen chondrosarcomas, other ones are rare. In general, biology of sarcomas is closely related to pediatric malignancies with fast growth, local aggressiveness, tendency to early hematogenic dissemination and chemo sensitivity. Diagnostics and treatment of bone sarcomas should be done in well experienced centres due to low incidence and broad issue of this topic. An interdisciplinary approach and staff education is essential in due care of patients with bone sarcoma. If these criteria are achieved, the cure rate is contemporary at 65 - 70 %, while some subpopulation of patients has chance for cure up to 90 %. Osteosarcoma and Ewing sarcoma/PNET are discussed below as types of most frequent bone sarcoma. (author)

  20. 3D temporal subtraction on multislice CT images using nonlinear warping technique

    Science.gov (United States)

    Ishida, Takayuki; Katsuragawa, Shigehiko; Kawashita, Ikuo; Kim, Hyounseop; Itai, Yoshinori; Awai, Kazuo; Li, Qiang; Doi, Kunio

    2007-03-01

    The detection of very subtle lesions and/or lesions overlapped with vessels on CT images is a time consuming and difficult task for radiologists. In this study, we have developed a 3D temporal subtraction method to enhance interval changes between previous and current multislice CT images based on a nonlinear image warping technique. Our method provides a subtraction CT image which is obtained by subtraction of a previous CT image from a current CT image. Reduction of misregistration artifacts is important in the temporal subtraction method. Therefore, our computerized method includes global and local image matching techniques for accurate registration of current and previous CT images. For global image matching, we selected the corresponding previous section image for each current section image by using 2D cross-correlation between a blurred low-resolution current CT image and a blurred previous CT image. For local image matching, we applied the 3D template matching technique with translation and rotation of volumes of interests (VOIs) which were selected in the current and the previous CT images. The local shift vector for each VOI pair was determined when the cross-correlation value became the maximum in the 3D template matching. The local shift vectors at all voxels were determined by interpolation of shift vectors of VOIs, and then the previous CT image was nonlinearly warped according to the shift vector for each voxel. Finally, the warped previous CT image was subtracted from the current CT image. The 3D temporal subtraction method was applied to 19 clinical cases. The normal background structures such as vessels, ribs, and heart were removed without large misregistration artifacts. Thus, interval changes due to lung diseases were clearly enhanced as white shadows on subtraction CT images.

  1. Informed baseline subtraction of proteomic mass spectrometry data aided by a novel sliding window algorithm.

    Science.gov (United States)

    Stanford, Tyman E; Bagley, Christopher J; Solomon, Patty J

    2016-01-01

    Proteomic matrix-assisted laser desorption/ionisation (MALDI) linear time-of-flight (TOF) mass spectrometry (MS) may be used to produce protein profiles from biological samples with the aim of discovering biomarkers for disease. However, the raw protein profiles suffer from several sources of bias or systematic variation which need to be removed via pre-processing before meaningful downstream analysis of the data can be undertaken. Baseline subtraction, an early pre-processing step that removes the non-peptide signal from the spectra, is complicated by the following: (i) each spectrum has, on average, wider peaks for peptides with higher mass-to-charge ratios ( m / z ), and (ii) the time-consuming and error-prone trial-and-error process for optimising the baseline subtraction input arguments. With reference to the aforementioned complications, we present an automated pipeline that includes (i) a novel 'continuous' line segment algorithm that efficiently operates over data with a transformed m / z -axis to remove the relationship between peptide mass and peak width, and (ii) an input-free algorithm to estimate peak widths on the transformed m / z scale. The automated baseline subtraction method was deployed on six publicly available proteomic MS datasets using six different m/z-axis transformations. Optimality of the automated baseline subtraction pipeline was assessed quantitatively using the mean absolute scaled error (MASE) when compared to a gold-standard baseline subtracted signal. Several of the transformations investigated were able to reduce, if not entirely remove, the peak width and peak location relationship resulting in near-optimal baseline subtraction using the automated pipeline. The proposed novel 'continuous' line segment algorithm is shown to far outperform naive sliding window algorithms with regard to the computational time required. The improvement in computational time was at least four-fold on real MALDI TOF-MS data and at least an order of

  2. Digital image comparison by subtracting contextual transformations—percentile rank order differentiation

    Science.gov (United States)

    Wehde, M. E.

    1995-01-01

    The common method of digital image comparison by subtraction imposes various constraints on the image contents. Precise registration of images is required to assure proper evaluation of surface locations. The attribute being measured and the calibration and scaling of the sensor are also important to the validity and interpretability of the subtraction result. Influences of sensor gains and offsets complicate the subtraction process. The presence of any uniform systematic transformation component in one of two images to be compared distorts the subtraction results and requires analyst intervention to interpret or remove it. A new technique has been developed to overcome these constraints. Images to be compared are first transformed using the cumulative relative frequency as a transfer function. The transformed images represent the contextual relationship of each surface location with respect to all others within the image. The process of differentiating between the transformed images results in a percentile rank ordered difference. This process produces consistent terrain-change information even when the above requirements necessary for subtraction are relaxed. This technique may be valuable to an appropriately designed hierarchical terrain-monitoring methodology because it does not require human participation in the process.

  3. A method for subtraction of the extrarenal 'background' in dynamic 131I-hippurate renoscintigraphy

    International Nuclear Information System (INIS)

    Mlodkowska, E.; Liniecki, J.; Surma, M.

    1979-01-01

    Using a Toshiba GC-401 gamma camera with MDS computer Trinary a new method was developed for subtracting the extrarenal (extracanalicular) 'background' from the count rate recorded over the kidneys after intravenous administration of 131 I-hippurate. Mean subtraction factors of the 'blood' activity curve were calculated from a study of 27 patients who were given 51 Cr-HSA for purposes of conventional renography with 'background' subtraction. The values of the mean subtraction factors anti Fsub(R,L) for the right and left kidney, by which a blood count rate should be multiplied amounted to 0.86 +- 0.12 and 0.79 +- 0.13, respectively. A comparison of the coefficients of variation of the pure renal signal when mean vs. individually determined subtraction factors were used, and the verification of the method in unilaterally nephrectomized patients have demonstrated that determination of the factors, anti Fsub(R,L), for each patient individually is not required and sufficient precision can be obtained by using the method and factors reported in this study. (orig.) [de

  4. Tumor scintigraphy by the method for subtracting the initial image with technetium-99m labeled antibody

    International Nuclear Information System (INIS)

    Karube, Yoshiharu; Katsuno, Kentaro; Ito, Sanae; Matsunaga, Kazuhisa; Takata, Jiro; Kuroki, Masahide; Murakami, Masaaki; Matsuoka, Yuji

    1999-01-01

    The method for subtracting the initial image from the localization image was evaluated for radioimmunoscintigraphy of tumors with technetium-99m (Tc-99m) labeled antibodies. Monoclonal antibodies were parental mouse and mouse-human chimeric antibodies to carcinoembryonic antigen (CEA), designated F11-39 and ChF11-39, respectively, both of which have been found to discriminate CEA in tumor tissues from the CEA-related antigens. After reduction of the intrinsic disulfide bonds, these antibodies were labeled with Tc-99m. In vivo studies were performed on athymic nude mice bearing the human CEA-producing gastric carcinoma xenografts. Though biodistribution results showed selective and progressive accumulation of Tc-99m labeled antibodies at the tumor site, high radioactivity in blood was inappropriate for scintigraphic visualization of the tumors within a few hours. We examined the subtraction of the initial Tc-99m image from the Tc-99m localization image after a few hours. Subtracted images of the same count reflected the in vivo behavior of the Tc-99m radioactivity. The subtracted scintigrams revealed excellent tumor images with no significant extrarenal background. Visualization of the tumor site was dependent on antigen-specific binding and nonspecific exudation. These results demonstrate that a method of subtraction of the initial image may serve as a potentially useful diagnostic method for an abnormal site for agents with a low pharmacokinetic value. (author)

  5. Bone--bone marrow interactions

    International Nuclear Information System (INIS)

    Patt, H.M.

    1976-01-01

    Within medullary cavities, blood formation tends to be concentrated near bone surfaces and this raises interesting questions about hematopoietic consequences of radionuclide fixation in osseous tissue. Thus, it may be important, on the one hand, to consider the medullary radiation dose distribution as well as total marrow dose from bone-bound radioelements and, on the other, to inquire about possible hematopoietic implications of radiation damage to endosteal surfaces per se. The reasons for this are discussed

  6. Introducing the CTA concept

    Czech Academy of Sciences Publication Activity Database

    Acharya, B.S.; Actis, M.; Aghajani, T.; Chudoba, Jiří; Ebr, Jan; Hrabovský, Miroslav; Mandát, Dušan; Palatka, Miroslav; Pech, Miroslav; Prouza, Michael; Řídký, Jan; Schovánek, Petr; Trávníček, Petr

    2013-01-01

    Roč. 43, SI (2013), s. 3-18 ISSN 0927-6505 R&D Projects: GA MŠk(CZ) 7AMB12AR013; GA MŠk LE13012 Institutional support: RVO:68378271 Keywords : TeV gamma-ray astronomy * air showers * Cherenkov telescopes Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 4.450, year: 2013 http://ac.els-cdn.com/S0927650513000169/1-s2.0-S0927650513000169-main.pdf?_tid=8de598aa-5113-11e3-942f-00000aab0f02&acdnat=1384863197_19119f28d7223184

  7. CT Angiography (CTA)

    Science.gov (United States)

    ... special computer and software and reviewed in different planes and projections. top of page What are some ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ...

  8. Safe zones and a technical guide for cerclage wiring of the femur: a computed topographic angiogram (CTA) study.

    Science.gov (United States)

    Apivatthakakul, Theerachai; Siripipattanamongkol, P; Oh, Chang-Wug; Sananpanich, K; Phornphutkul, C

    2018-01-01

    Cerclage wiring for reduction of complex femoral shaft fractures can create iatrogenic vascular injury. To describe the anatomical relation of blood vessels to the femur and develop a technical guide for safe passage of cerclage wire. CT lower-limb angiographs (CTA) of 80 patients were reviewed and analysed to identify the superficial femoral artery (SFA) and the deep femoral artery (DFA) as well as the relation of those arteries to the femoral cortex. The total length of the femur was measured and divided into eight equal segments (seven levels). At each level, the medial half of the femur was divided into eight sectors labelled A through H and the position of the SFA and DFA was recorded. The shortest distance between the femoral cortex and the SFA and DFA at each level was measured. The data was analysed using STATA version 10.0. The average total femoral length from the tip of greater trochanter to lateral joint line was 402.98 ± 26.16 cm. The average distances from the SFA to the femur (d1) for levels 1 through 7 were 37.20 ± 5.0, 32.09 ± 4.74, 27.13 ± 4.19, 27.71 ± 5.46, 23.71 ± 4.40, 13.63 ± 3.59 and 10.08 ± 3.09 mm, respectively. The average distances between the DFA and the femur (d2) for levels 1 through 3 were 26.70 ± 4.13, 14.76 ± 3.27 and 9.58 ± 3.79 mm, respectively. The position of the SFA is located in sectors B through E at levels 1-3 and in sectors E through H at levels 4-7 and the position of the DFA located in sectors B through F at levels 1-3. Cerclage wiring should be started from the posterior intermuscular septum at the linea aspera. The safe area is the proximal half (midshaft) of the femur where the SFA and DFA lie at a safe distance from the femur. Between the midshaft and the distal 1/4, insertion of the passer must be done meticulously with the tip kept close to posteromedial cortex. Below the distal 1/4, the tip of the passer should be kept close to the posterior cortex to avoid injury to the SFA and

  9. [The backgroud sky subtraction around [OIII] line in LAMOST QSO spectra].

    Science.gov (United States)

    Shi, Zhi-Xin; Comte, Georges; Luo, A-Li; Tu, Liang-Ping; Zhao, Yong-Heng; Wu, Fu-Chao

    2014-11-01

    At present, most sky-subtraction methods focus on the full spectrum, not the particular location, especially for the backgroud sky around [OIII] line which is very important to low redshift quasars. A new method to precisely subtract sky lines in local region is proposed in the present paper, which sloves the problem that the width of Hβ-[OIII] line is effected by the backgroud sky subtraction. The exprimental results show that, for different redshift quasars, the spectral quality has been significantly improved using our method relative to the original batch program by LAMOST. It provides a complementary solution for the small part of LAMOST spectra which are not well handled by LAMOST 2D pipeline. Meanwhile, This method has been used in searching for candidates of double-peaked Active Galactic Nuclei.

  10. Dynamic contrast-enhanced subtraction MR angiography in intracranial vascular abnormalities

    International Nuclear Information System (INIS)

    Takano, K.; Ono, H.; Utsunomiya, H.; Okazaki, M.; Tanaka, A.

    1999-01-01

    We present our clinical experience with dynamic contrast-enhanced MR angiography (MRA) with subtraction for assessing intracranial vascular abnormalities. Ten patients with various cerebrovascular disorders underwent dynamic contrast-enhanced MRA on a 1.0-T system. Thirty sections (2 mm) were acquired in 29-30 s. Maximum intensity projection images and subtracted source images were compared with those obtained by conventional angiography. In all cases, the presence or absence of abnormalities in the targeted vessels, as well as the morphology of the sagittal sinuses, was clearly visualized as in conventional angiography, without any obstructions such as hyperintense hematomas or thrombi, or intraluminal turbulence. Although the temporal and spatial resolutions with current hardware are insufficient, these preliminary results suggest that dynamic contrast-enhanced MRA with subtraction may be useful for assessing vascular lesions with hemorrhage or thrombus, and the dural sinuses. (orig.)

  11. Two-dimensional real-time imaging system for subtraction angiography using an iodine filter

    Science.gov (United States)

    Umetani, Keiji; Ueda, Ken; Takeda, Tohoru; Anno, Izumi; Itai, Yuji; Akisada, Masayoshi; Nakajima, Teiichi

    1992-01-01

    A new type of subtraction imaging system was developed using an iodine filter and a single-energy broad bandwidth monochromatized x ray. The x-ray images of coronary arteries made after intravenous injection of a contrast agent are enhanced by an energy-subtraction technique. Filter chopping of the x-ray beam switches energies rapidly, so that a nearly simultaneous pair of filtered and nonfiltered images can be made. By using a high-speed video camera, a pair of two 512 × 512 pixel images can be obtained within 9 ms. Three hundred eighty-four images (raw data) are stored in a 144-Mbyte frame memory. After phantom studies, in vivo subtracted images of coronary arteries in dogs were obtained at a rate of 15 images/s.

  12. Aggression-related brain function assessed with the Point Subtraction Aggression Paradigm in fMRI

    DEFF Research Database (Denmark)

    Skibsted, Anine P; Cunha-Bang, Sofi da; Carré, Justin M

    2017-01-01

    The Point Subtraction Aggression Paradigm (PSAP) measures aggressive behavior in response to provocations. The aim of the study was to implement the PSAP in a functional neuroimaging environment (fMRI) and evaluate aggression-related brain reactivity including response to provocations and associa......The Point Subtraction Aggression Paradigm (PSAP) measures aggressive behavior in response to provocations. The aim of the study was to implement the PSAP in a functional neuroimaging environment (fMRI) and evaluate aggression-related brain reactivity including response to provocations...... and associations with aggression within the paradigm. Twenty healthy participants completed two 12-min PSAP sessions within the scanner. We evaluated brain responses to aggressive behavior (removing points from an opponent), provocations (point subtractions by the opponent), and winning points. Our results showed...... with the involvement of these brain regions in emotional and impulsive behavior. Striatal reactivity may suggest an involvement of reward during winning and stealing points....

  13. Enhancing quantum entanglement for continuous variables by a coherent superposition of photon subtraction and addition

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Su-Yong; Kim, Ho-Joon [Department of Physics, Texas A and M University at Qatar, P.O. Box 23874, Doha (Qatar); Ji, Se-Wan [School of Computational Sciences, Korea Institute for Advanced Study, Seoul 130-012 (Korea, Republic of); Nha, Hyunchul [Department of Physics, Texas A and M University at Qatar, P.O. Box 23874, Doha (Qatar); Institute fuer Quantenphysik, Universitaet Ulm, D-89069 Ulm (Germany)

    2011-07-15

    We investigate how the entanglement properties of a two-mode state can be improved by performing a coherent superposition operation ta+ra{sup {dagger}} of photon subtraction and addition, proposed by Lee and Nha [Phys. Rev. A 82, 053812 (2010)], on each mode. We show that the degree of entanglement, the Einstein-Podolsky-Rosen-type correlation, and the performance of quantum teleportation can be all enhanced for the output state when the coherent operation is applied to a two-mode squeezed state. The effects of the coherent operation are more prominent than those of the mere photon subtraction a and the addition a{sup {dagger}} particularly in the small-squeezing regime, whereas the optimal operation becomes the photon subtraction (case of r=0) in the large-squeezing regime.

  14. Spectral Subtraction Approach for Interference Reduction of MIMO Channel Wireless Systems

    Directory of Open Access Journals (Sweden)

    Tomohiro Ono

    2005-08-01

    Full Text Available In this paper, a generalized spectral subtraction approach for reducing additive impulsive noise, narrowband signals, white Gaussian noise and DS-CDMA interferences in MIMO channel DS-CDMA wireless communication systems is investigated. The interference noise reduction or suppression is essential problem in wireless mobile communication systems to improve the quality of communication. The spectrum subtraction scheme is applied to the interference noise reduction problems for noisy MIMO channel systems. The interferences in space and time domain signals can effectively be suppressed by selecting threshold values, and the computational load with the FFT is not large. Further, the fading effects of channel are compensated by spectral modification with the spectral subtraction process. In the simulations, the effectiveness of the proposed methods for the MIMO channel DS-CDMA is shown to compare with the conventional MIMO channel DS-CDMA.

  15. Effect of relative nanohole position on colour purity of ultrathin plasmonic subtractive colour filters

    International Nuclear Information System (INIS)

    Sun, L B; Hu, X L; Zhang, D X; Zeng, Beibei; Wang, L S; Yang, S M; Tai, R Z; Fecht, H J; Jiang, J Z

    2015-01-01

    Plasmonic subtractive color filters through patterning periodic nanostructures on ultrathin Ag films deposited on a glass substrate, exhibiting good durability, simple fabrication, and flexible color tunability, have attracted considerable attention due to their tremendous potential applications. While previous studies have mainly focused on their extraordinary physical mechanisms, color purity, which is another key parameter for high quality imaging applications, has been much less investigated. In this work, we demonstrate that the relative position of nanoholes patterned on ultrathin Ag films can largely affect the color purity of plasmonic subtractive color filters. The calculated results agree reasonably well with the experimental data, revealing that the purity of subtractive colors can be improved by changing the nanohole arrays from square lattice to triangular lattice without reducing transmission at visible frequencies. In addition, underlying mechanisms are clarified by systematically analyzing the dominant valley in transmission spectra. (paper)

  16. A simultaneous all-optical half/full-subtraction strategy using cascaded highly nonlinear fibers

    Science.gov (United States)

    Singh, Karamdeep; Kaur, Gurmeet; Singh, Maninder Lal

    2018-02-01

    Using non-linear effects such as cross-gain modulation (XGM) and cross-phase modulation (XPM) inside two highly non-linear fibres (HNLF) arranged in cascaded configuration, a simultaneous half/full-subtracter is proposed. The proposed simultaneous half/full-subtracter design is attractive due to several features such as input data pattern independence and usage of minimal number of non-linear elements i.e. HNLFs. Proof of concept simulations have been conducted at 100 Gbps rate, indicating fine performance, as extinction ratio (dB) > 6.28 dB and eye opening factors (EO) > 77.1072% are recorded for each implemented output. The proposed simultaneous half/full-subtracter can be used as a key component in all-optical information processing circuits.

  17. Venous digital subtraction angiography for diagnosis of renal artery stenosis in arterial hypertony

    International Nuclear Information System (INIS)

    Schoerner, W.; Kempter, H.; Banzer, D.; Aviles, C.; Weiss, T.; Felix, R.

    1984-01-01

    Venous digital subtraction angiography was performed in 248 patients for the diagnosis of renal arterial stenosis. In 88% of the investigations the stenosis could be found. Comparison of digital angiography and conventional angiography was made for 57 renal arteries (25 investigations). In 52 renal arteries we found the same results with both methods, in 5 renal arteries we found the same results with both methods, in 5 renal arteries the digital angiography showed false positive results. The spatial resolution of digital subtraction angiography is sufficient for the correct diagnosis of significant renal arterial stenosis. With regard to the lower invasion of digital subtraction angiography compared to conventional angiography the first method should be used for clarification of renal arterial hypertension. (orig.)

  18. Continuous-variable measurement-device-independent quantum key distribution with photon subtraction

    Science.gov (United States)

    Ma, Hong-Xin; Huang, Peng; Bai, Dong-Yun; Wang, Shi-Yu; Bao, Wan-Su; Zeng, Gui-Hua

    2018-04-01

    It has been found that non-Gaussian operations can be applied to increase and distill entanglement between Gaussian entangled states. We show the successful use of the non-Gaussian operation, in particular, photon subtraction operation, on the continuous-variable measurement-device-independent quantum key distribution (CV-MDI-QKD) protocol. The proposed method can be implemented based on existing technologies. Security analysis shows that the photon subtraction operation can remarkably increase the maximal transmission distance of the CV-MDI-QKD protocol, which precisely make up for the shortcoming of the original CV-MDI-QKD protocol, and one-photon subtraction operation has the best performance. Moreover, the proposed protocol provides a feasible method for the experimental implementation of the CV-MDI-QKD protocol.

  19. Simultaneous optical digital half-subtraction and -addition using SOAs and a PPLN waveguide.

    Science.gov (United States)

    McGeehan, John E; Kumar, Saurabh; Willner, Alan E

    2007-04-30

    We demonstrate an optical half-subtracter and half-adder module that performs simultaneous bit-wise subtraction and addition of two 5 Gbit/s RZ data streams. We generate Borrow (/X*Y) and Difference/Sum (X plus sign in circleY, or XOR) outputs using cross-gain modulation (XGM) in two parallel SOAs. Taking advantage of the gain saturation inherent to SOAs, we generate two signals, /X*Y, and X*/Y, and combine them using a passive optical coupler to generate the XOR Difference/Sum output. We use difference-frequency-generation-based lambda-conversion in a PPLN waveguide to generate the Carry (X*Y) output. The PPLN waveguide allows bit-synchronous wavelength shifting, is wide-bandwidth, and offers no intrinsic chirp. Our module uses three active elements to perform simultaneous half-subtraction and addition, and carries a maximum power penalty of 1.0 dB.

  20. Clinical application of subtraction CT imaging for evaluation of pulmonary vascular permeability

    International Nuclear Information System (INIS)

    Kato, Shiro; Asai, Toshihiko; Yatagai, Shigeo; Oonuma, Noboru; Ohno, Kunihiko; Nakamoto, Takaaki; Iizuka, Masahiko

    1991-01-01

    In this clinical study, one normal subject, one patient with primary interstitial pneumonia, one patient with segmental pneumonia due to Staphylococcus aureus, one patient with post-operative esophageal carcinoma, and two patients with mitral stenosis were studied. Dynamic CT scan images under continuous injection of low osmotic contrast medium were analyzed in series, in an attempt to evaluate vascular permeability quantitatively. The following results were obtained. Subtraction CT scan image 10 minutes after the start of contrast medium injection in two patients with pneumonia, showed a reduction of pulmonary vascular permeability following therapy. Subtraction CT scan image of the patient with post-operative esophageal carcinoma treated with 25 Gy radiation showed a discrepancy between pulmonary vascular permeability and other findings. In hemodynamically stable patients with mitral stenosis, subtraction CT images demonstrated that pulmonary vascular permeability was not affected by pulmonary congestion, irrespective of its severity. (author)

  1. Evaluation of the minimum iodine concentration for contrast-enhanced subtraction mammography

    International Nuclear Information System (INIS)

    Baldelli, P; Bravin, A; Maggio, C Di; Gennaro, G; Sarnelli, A; Taibi, A; Gambaccini, M

    2006-01-01

    Early manifestation of breast cancer is often very subtle and is displayed in a complex and variable pattern of normal anatomy that may obscure the disease. The use of dual-energy techniques, that can remove the structural noise, and contrast media, that enhance the region surrounding the tumour, could help us to improve the detectability of the lesions. The aim of this work is to investigate the use of an iodine-based contrast medium in mammography with two different double exposure techniques: K-edge subtraction mammography and temporal subtraction mammography. Both techniques have been investigated by using an ideal source, like monochromatic beams produced at a synchrotron radiation facility and a clinical digital mammography system. A dedicated three-component phantom containing cavities filled with different iodine concentrations has been developed and used for measurements. For each technique, information about the minimum iodine concentration, which provides a significant enhancement of the detectability of the pathology by minimizing the risk due to high dose and high concentration of contrast medium, has been obtained. In particular, for cavities of 5 and 8 mm in diameter filled with iodine solutions, the minimum concentration needed to obtain a contrast-to-noise ratio of 5 with a mean glandular dose of 2 mGy has been calculated. The minimum concentrations estimated with monochromatic beams and K-edge subtraction mammography are 0.9 mg ml -1 and 1.34 mg ml -1 for the biggest and smallest details, respectively, while for temporal subtraction mammography they are 0.84 mg ml -1 and 1.31 mg ml -1 . With the conventional clinical system the minimum concentrations for the K-edge subtraction mammography are 4.13 mg ml -1 (8 mm diameter) and 5.75 mg ml -1 (5 mm diameter), while for the temporal subtraction mammography they are 1.01 mg ml -1 (8 mm diameter) and 1.57 mg ml -1 (5 mm diameter)

  2. A Novel Approach to Reinstating Tolerance in Experimental Autoimmune Myasthenia Gravis Using a Targeted Fusion Protein, mCTA1–T146

    Directory of Open Access Journals (Sweden)

    Alessandra Consonni

    2017-09-01

    Full Text Available Reinstating tissue-specific tolerance has attracted much attention as a means to treat autoimmune diseases. However, despite promising results in rodent models of autoimmune diseases, no established tolerogenic therapy is clinically available yet. In the experimental autoimmune myasthenia gravis (EAMG model several protocols have been reported that induce tolerance against the prime disease-associated antigen, the acetylcholine receptor (AChR at the neuromuscular junction. Using the whole AChR, the extracellular part or peptides derived from the receptor, investigators have reported variable success with their treatments, though, usually relatively large amounts of antigen has been required. Hence, there is a need for better formulations and strategies to improve on the efficacy of the tolerance-inducing therapies. Here, we report on a novel targeted fusion protein carrying the immunodominant peptide from AChR, mCTA1–T146, which given intranasally in repeated microgram doses strongly suppressed induction as well as ongoing EAMG disease in mice. The results corroborate our previous findings, using the same fusion protein approach, in the collagen-induced arthritis model showing dramatic suppressive effects on Th1 and Th17 autoaggressive CD4 T cells and upregulated regulatory T cell activities with enhanced IL10 production. A suppressive gene signature with upregulated expression of mRNA for TGFβ, IL10, IL27, and Foxp3 was clearly detectable in lymph node and spleen following intranasal treatment with mCTA1–T146. Amelioration of EAMG disease was accompanied by reduced loss of muscle AChR and lower levels of anti-AChR serum antibodies. We believe this targeted highly effective fusion protein mCTA1–T146 is a promising candidate for clinical evaluation in myasthenia gravis patients.

  3. Using a digital signal processor as a data stream controller for digital subtraction angiography

    International Nuclear Information System (INIS)

    Meng, J.D.; Katz, J.E.

    1991-10-01

    High speed, flexibility, and good arithmetic abilities make digital signal processors (DSP) a good choice as input/output controllers for real time applications. The DSP can be made to pre-process data in real time to reduce data volume, to open early windows on what is being acquired and to implement local servo loops. We present an example of a DSP as an input/output controller for a digital subtraction angiographic imaging system. The DSP pre-processes the raw data, reducing data volume by a factor of two, and is potentially capable of producing real-time subtracted images for immediate display

  4. Subtracted Dispersion Relations for In-medium Meson Correlators in QCD Sum Rules

    Energy Technology Data Exchange (ETDEWEB)

    Florkowski, W; Broniowski, W [The H. Niewodniczanski Institute of Nuclear Physics, Cracow (Poland)

    1999-01-01

    We analyze subtracted dispersion relations for meson correlators at finite baryon density and temperature. Such relations are needed for QCD sum rules. We point out that importance of scattering terms, as well as finite, well-defined subtraction constants. Both are necessary for consistency, in particular for the equality of the longitudinal and transverse correlators in the limit of the vanishing three-momentum of mesons relative to the medium. We present detailed calculations in various mesonic channels of the Fermi gas of nucleons. (author)

  5. Procedures for imaging of hemodialysis fistulas with particular reference to digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Erasmi-Koerber, H.; Wimmer, G.; Koeln Univ.

    1983-01-01

    All angiographic procedures established for imaging of hemodialysis fistulas, such as direct venous angiography, intravenous subtraction angiography and arteriography by direct puncture of the brachial artery of by Seldinger's transfemoral technique, can also be effected with digital image processing. Depending on the angiographic technique, the use of digital subtraction angiography has several advantages: lower doses and concentrations of the contrast agent, lower risk of complications (thrombosis of the fistula, vasospasm) and freedom from pain. In addition, there is a marked reduction of examination time and film cost. (orig.)

  6. A single injection technique for subtraction of blood background in 131I-hippuran renograms

    International Nuclear Information System (INIS)

    Rutland, M.D.

    1979-01-01

    A method of subtracting blood background during probe-renography is presented which does not require a prior injection of RIHSA and which produces results approximately 11% higher than the RIHSA method. The new method treats the renogram up to two-and-a-half minutes as a combination of a fraction of the blood curve and a fraction of the integral of the blood curve. Analysis of the data, using either a computer or a programmed calculator, enables these two fractions to be calculated, hence producing the 'background subtraction factor' and the 'uptake constant'. (author)

  7. Higgs boson production in association with a jet using jettiness subtraction

    Directory of Open Access Journals (Sweden)

    Radja Boughezal

    2015-09-01

    Full Text Available We use the recently proposed jettiness-subtraction scheme to provide the complete calculation of Higgs boson production in association with a jet in hadronic collisions through next-to-next-to-leading order in perturbative QCD. This method exploits the observation that the N-jettiness event-shape variable completely describes the singularity structure of QCD when final-state colored particles are present. Our results are in agreement with a recent computation of the gg and qg partonic initial states based on sector-improved residue subtraction. We present phenomenological results for both fiducial cross sections and distributions at the LHC.

  8. Speech Enhancement by Multichannel Crosstalk Resistant ANC and Improved Spectrum Subtraction

    Directory of Open Access Journals (Sweden)

    Zeng Qingning

    2006-01-01

    Full Text Available A scheme combining multichannel crosstalk resistant adaptive noise cancellation (MCRANC algorithm and improved spectrum subtraction (ISS algorithm is presented to enhance noise carrying speech signals. The scheme would permit locating the microphones in close proximity by virtue of using MCRANC which has the capability of removing the crosstalk effect. MCRANC would also permit canceling out nonstationary noise and making the residual noise more stationary for further treatment by ISS algorithm. Experimental results have indicated that this scheme outperforms many commonly used techniques in the sense of SNR improvement and music effect reduction which is an inevitable byproduct of the spectrum subtraction algorithm.

  9. A Feature Subtraction Method for Image Based Kinship Verification under Uncontrolled Environments

    DEFF Research Database (Denmark)

    Duan, Xiaodong; Tan, Zheng-Hua

    2015-01-01

    The most fundamental problem of local feature based kinship verification methods is that a local feature can capture the variations of environmental conditions and the differences between two persons having a kin relation, which can significantly decrease the performance. To address this problem...... the feature distance between face image pairs with kinship and maximize the distance between non-kinship pairs. Based on the subtracted feature, the verification is realized through a simple Gaussian based distance comparison method. Experiments on two public databases show that the feature subtraction method...

  10. Similarity renormalization group evolution of N N interactions within a subtractive renormalization scheme

    Directory of Open Access Journals (Sweden)

    Durães F.O.

    2010-04-01

    Full Text Available We apply the similarity renormalization group (SRG approach to evolve a nucleon-nucleon (N N interaction in leading-order (LO chiral effective field theory (ChEFT, renormalized within the framework of the subtracted kernel method (SKM. We derive a fixed-point interaction and show the renormalization group (RG invariance in the SKM approach. We also compare the evolution of N N potentials with the subtraction scale through a SKM RG equation in the form of a non-relativistic Callan-Symanzik (NRCS equation and the evolution with the similarity cutoff through the SRG transformation.

  11. Parathyroid localizlation by 201Tl-99mTc subtraction scintigraphy

    International Nuclear Information System (INIS)

    Rademaker, P.; Meijer, S.; Piers, D.A.

    1990-01-01

    Subtraction scintigraphy with 201 Tl and 99m Tc for parathyroid localization was performed preoperatively in 13 patients with chronic renal failure and secondary hyperparathyroidism. Twenty of the 37 examined pathological glands were predicted correctly (sensitivity 54%). In 3 patients with recurrent hyperparathyroidism after surgery all pathological glands found at second operation had been detected correctly by subtraction scintigraphy. We conclude that this localization method has a limited value when used prior to first neck exploration in secondary hyperparathyroidism. In persistent hyperparathyroidism after surgery it may play a useful role in localizing missed and ectopic glands. (author)

  12. Subtraction method of computing QCD jet cross sections at NNLO accuracy

    Science.gov (United States)

    Trócsányi, Zoltán; Somogyi, Gábor

    2008-10-01

    We present a general subtraction method for computing radiative corrections to QCD jet cross sections at next-to-next-to-leading order accuracy. The steps needed to set up this subtraction scheme are the same as those used in next-to-leading order computations. However, all steps need non-trivial modifications, which we implement such that that those can be defined at any order in perturbation theory. We give a status report of the implementation of the method to computing jet cross sections in electron-positron annihilation at the next-to-next-to-leading order accuracy.

  13. Subtraction method of computing QCD jet cross sections at NNLO accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Trocsanyi, Zoltan [University of Debrecen and Institute of Nuclear Research of the Hungarian Academy of Sciences, H-4001 Debrecen P.O.Box 51 (Hungary)], E-mail: Zoltan.Trocsanyi@cern.ch; Somogyi, Gabor [University of Zuerich, Winterthurerstrasse 190, CH-8057 Zuerich (Switzerland)], E-mail: sgabi@physik.unizh.ch

    2008-10-15

    We present a general subtraction method for computing radiative corrections to QCD jet cross sections at next-to-next-to-leading order accuracy. The steps needed to set up this subtraction scheme are the same as those used in next-to-leading order computations. However, all steps need non-trivial modifications, which we implement such that that those can be defined at any order in perturbation theory. We give a status report of the implementation of the method to computing jet cross sections in electron-positron annihilation at the next-to-next-to-leading order accuracy.

  14. Bone mineral content and bone metabolism in young adults with severe periodontitis

    DEFF Research Database (Denmark)

    Wowern von, N.; Westergaard, J.; Kollerup, G.

    2001-01-01

    Bone loss, bone markers, bone metabolism, bone mineral content, osteoporosis, severe periodontitis......Bone loss, bone markers, bone metabolism, bone mineral content, osteoporosis, severe periodontitis...

  15. From bone biology to bone analysis.

    NARCIS (Netherlands)

    Schoenau, E.; Saggese, G.; Peter, F.; Baroncelli, G.I.; Shaw, N.J.; Crabtree, N.J.; Zadik, Z.; Neu, C.M.; Noordam, C.; Radetti, G.; Hochberg, Z.

    2004-01-01

    Bone development is one of the key processes characterizing childhood and adolescence. Understanding this process is not only important for physicians treating pediatric bone disorders, but also for clinicians and researchers dealing with postmenopausal and senile osteoporosis. Bone densitometry has

  16. Preparation and certification of the Polish reference material Virginia Tobacco Leaves (CTA-VTL-2) for inorganic trace analysis including microanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Dybczynski, R.; Polkowska-Motrenko, H.; Samczynski, Z.; Szopa, Z.

    1997-12-31

    A new Polish certified reference material Virginia Tobacco Leaves (CTA-VTL-2) for inorganic trace analysis including microanalysis has been prepared. Certification of the candidate reference material was based on the world-wide interlaboratory comparison in which 60 laboratories from 18 countries, participated using various analytical methods and techniques. Data evaluation performed by means of the new multifunctional software package -SSQC. Recommended values were assigned for 33 and `information` values for 10 elements, respectively. The validity of `certified` values was confirmed for several elements using `very accurate` methods developed in this Laboratory. (author). 47 refs, 28 figs, 12 tabs.

  17. Very High Energy astronomy from H.E.S.S. to CTA. Opening of a new astronomical window on the non-thermal Universe

    International Nuclear Information System (INIS)

    Naurois, Mathieu de

    2012-01-01

    The last ten years saw the emergence of Imaging Atmospheric Cherenkov Telescopes as a mature and efficient technique for the study of the Very High Energy Universe, leading to the successful opening, mainly by the HESS experiment, of our understanding of the non-thermal Universe. This Habilitation thesis summaries ten years of research in Very High Energy gamma-ray astronomy with HESS and CTA. In the first part, instrumental aspects such as the experiment conception, its calibration, the reconstruction of the events and the data analysis are presented. The second parts draws a panorama of the main discoveries in the domain. (author)

  18. Preparation and certification of the Polish reference material Virginia Tobacco Leaves (CTA-VTL-2) for inorganic trace analysis including microanalysis

    International Nuclear Information System (INIS)

    Dybczynski, R.; Polkowska-Motrenko, H.; Samczynski, Z.; Szopa, Z.

    1997-01-01

    A new Polish certified reference material Virginia Tobacco Leaves (CTA-VTL-2) for inorganic trace analysis including microanalysis has been prepared. Certification of the candidate reference material was based on the world-wide interlaboratory comparison in which 60 laboratories from 18 countries, participated using various analytical methods and techniques. Data evaluation performed by means of the new multifunctional software package -SSQC. Recommended values were assigned for 33 and 'information' values for 10 elements, respectively. The validity of 'certified' values was confirmed for several elements using 'very accurate' methods developed in this Laboratory. (author)

  19. Bone lesion biopsy

    Science.gov (United States)

    Bone biopsy; Biopsy - bone ... the cut, then pushed and twisted into the bone. Once the sample is obtained, the needle is ... sample is sent to a lab for examination. Bone biopsy may also be done under general anesthesia ...

  20. Facts about Broken Bones

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Broken Bones KidsHealth / For Kids / Broken Bones What's in this ... sticking through the skin . What Happens When a Bone Breaks? It hurts to break a bone! It's ...

  1. Broken Bones (For Parents)

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Broken Bones KidsHealth / For Parents / Broken Bones What's in this ... bone fragments in place. When Will a Broken Bone Heal? Fractures heal at different rates, depending upon ...

  2. Comparison of the clinical efficacy of craniotomy and craniopuncture therapy for the early stage of moderate volume spontaneous intracerebral haemorrhage in basal ganglia: Using the CTA spot sign as an entry criterion.

    Science.gov (United States)

    Ge, Chunyan; Zhao, Wangmiao; Guo, Hong; Sun, Zhaosheng; Zhang, Wanzeng; Li, Xiaowei; Yang, Xuehui; Zhang, Jinrong; Wang, Dongxin; Xiang, Yi; Mao, Jianhui; Zhang, Wenchao; Guo, Hao; Zhang, Yazhao; Chen, Jianchao

    2018-06-01

    Surgical treatment is widely used for haematoma removal in spontaneous intracerebral haemorrhage (ICH) patients, but there is controversy about the selection of surgical methods. The CT angiography (CTA) spot sign has been proven to be a promising factor predicting haematoma expansion and is recommended as an entry criterion for haemostatic therapy in patients with ICH. This trial was designed to evaluate the clinical efficacy of two surgical methods (haematoma removal by craniotomy and craniopuncture combined with urokinase infusion) for patients in the early stage (≤6h from symptom onset) of spontaneous ICH with a moderate haematoma volume (30 ml - 60 ml). From January 2012 to July 2017, 196 eligible patients treated in our institution were enrolled according to the inclusion criteria. The patients were divided into the CTA spot sign positive type and CTA spot sign negative type according to the presence or absence of the CTA spot sign. For each type, the patients were randomly assigned to two groups, i.e., the craniotomy group, in which patients underwent craniotomy with haematoma removal, and the craniopuncture group, in which patients underwent minimally invasive craniopuncture combined with urokinase infusion therapy. Neurological function was evaluated with the Scandinavian Stroke Scale (SSS) at day 14. The disability level and the activities of daily living were assessed using a modified Rankin Scale (mRS) and Barthel Index (BI) at day 90. Case fatalities were recorded at day 14 and 90. Complications were recorded during hospitalization. For the CTA spot sign positive type, the craniotomy group had a higher SSS than that in the craniopuncture group (P spot sign negative type, there were no significant differences in the SSS, mRS, BI, fatality rate and complication rate between the two groups. ICH can be divided into the CTA spot sign positive and negative type according to the presence or absence of the CTA spot sign. For the CTA spot sign

  3. Bone scans

    International Nuclear Information System (INIS)

    Hetherington, V.J.

    1989-01-01

    Oftentimes, in managing podiatric complaints, clinical and conventional radiographic techniques are insufficient in determining a patient's problem. This is especially true in the early stages of bone infection. Bone scanning or imaging can provide additional information in the diagnosis of the disorder. However, bone scans are not specific and must be correlated with clinical, radiographic, and laboratory evaluation. In other words, bone scanning does not provide the diagnosis but is an important bit of information aiding in the process of diagnosis. The more useful radionuclides in skeletal imaging are technetium phosphate complexes and gallium citrate. These compounds are administered intravenously and are detected at specific time intervals postinjection by a rectilinear scanner with minification is used and the entire skeleton can be imaged from head to toe. Minification allows visualization of the entire skeleton in a single image. A gamma camera can concentrate on an isolated area. However, it requires multiple views to complete the whole skeletal image. Recent advances have allowed computer augmentation of the data received from radionucleotide imaging. The purpose of this chapter is to present the current radionuclides clinically useful in podiatric patients

  4. Osteoclasts prefer aged bone

    DEFF Research Database (Denmark)

    Henriksen, K; Leeming, Diana Julie; Byrjalsen, I

    2007-01-01

    We investigated whether the age of the bones endogenously exerts control over the bone resorption ability of the osteoclasts, and found that osteoclasts preferentially develop and resorb bone on aged bone. These findings indicate that the bone matrix itself plays a role in targeted remodeling...... of aged bones....

  5. Bone graft revascularization strategies

    NARCIS (Netherlands)

    Willems, W.F.

    2014-01-01

    Reconstruction of avascular necrotic bone by pedicled bone grafting is a well-known treatment with little basic research supporting its application. A new canine model was used to simulate carpal bone avascular necrosis. Pedicled bone grafting proved to increase bone remodeling and bone blood flow,

  6. Bone marker gene expression in calvarial bones: different bone microenvironments.

    Science.gov (United States)

    Al-Amer, Osama

    2017-12-01

    In calvarial mice, mesenchymal stem cells (MSCs) differentiate into osteoprogenitor cells and then differentiate into osteoblasts that differentiate into osteocytes, which become embedded within the bone matrix. In this case, the cells participating in bone formation include MSCs, osteoprogenitor cells, osteoblasts and osteocytes. The calvariae of C57BL/KaLwRijHsD mice consist of the following five bones: two frontal bones, two parietal bones and one interparietal bone. This study aimed to analyse some bone marker genes and bone related genes to determine whether these calvarial bones have different bone microenvironments. C57BL/KaLwRijHsD calvariae were carefully excised from five male mice that were 4-6 weeks of age. Frontal, parietal, and interparietal bones were dissected to determine the bone microenvironment in calvariae. Haematoxylin and eosin staining was used to determine the morphology of different calvarial bones under microscopy. TaqMan was used to analyse the relative expression of Runx2, OC, OSX, RANK, RANKL, OPG, N-cadherin, E-cadherin, FGF2 and FGFR1 genes in different parts of the calvariae. Histological analysis demonstrated different bone marrow (BM) areas between the different parts of the calvariae. The data show that parietal bones have the smallest BM area compared to frontal and interparietal bones. TaqMan data show a significant increase in the expression level of Runx2, OC, OSX, RANKL, OPG, FGF2 and FGFR1 genes in the parietal bones compared with the frontal and interparietal bones of calvariae. This study provides evidence that different calvarial bones, frontal, parietal and interparietal, contain different bone microenvironments.

  7. Addition Table of Colours: Additive and Subtractive Mixtures Described Using a Single Reasoning Model

    Science.gov (United States)

    Mota, A. R.; Lopes dos Santos, J. M. B.

    2014-01-01

    Students' misconceptions concerning colour phenomena and the apparent complexity of the underlying concepts--due to the different domains of knowledge involved--make its teaching very difficult. We have developed and tested a teaching device, the addition table of colours (ATC), that encompasses additive and subtractive mixtures in a single…

  8. Visualization of the renal venous system by renal arteriography with digital subtraction angiography

    International Nuclear Information System (INIS)

    Nagai, Jun

    1989-01-01

    The purpose of this study was to obtain vivid and precise images of intrarenal venous branching using DSA for renal arteriography. The type of system used was an ADAC DPS-4100C with 70-80 kVp, and 320 mA, 25-50 msec at 6 frames/sec. The duration was 10 sec and the matrix size was 512x512. In order to retain clear subtracted images of intrarenal venous branching with minimal noise the three frames were selected on the time-density curve of DSA: (Fig.3). 1) a frame on which renal arteries disappear (frame X), 2) the frame with highest renal venous density value as (frame Y), 3) the difference of the nephrogram density between X and Y frames in which only the density of the nephrogram decreases (frame Z). The mask image is the image subtracted by the equation of the weighted averaging method on X and Z frame and is subtracted from the image of Y frame in the final step. By this method, 40 kidneys in 36 patients were studied, and the intrarenal venous branches up to the interlobar vein was clearly demonstrated in 28 of these cases (70%). This method is useful to estimate the extent of intrarenal lesions and detect abnormal renal blood flow compared with conventional temporal subtraction method. (author)

  9. Application of the singularity subtraction method for (d,p) reactions on light nuclei

    International Nuclear Information System (INIS)

    Borbely, I.

    1974-01-01

    It is shown that the method of subtraction the nearest singularity can be used successfully for data processing of (d,p) reactions. The data on the nuclear structure, thus obtained, can then be used for a more efficient study of the reaction mechanism with the use of traditional methods

  10. Misconception on Addition and Subtraction of Fraction at Primary School Students in Fifth-Grade

    Science.gov (United States)

    Trivena, V.; Ningsih, A. R.; Jupri, A.

    2017-09-01

    This study aims to investigate the mastery concept of the student in mathematics learning especially in addition and subtraction of fraction at primary school level. By using qualitative research method, the data were collected from 23 grade five students (10-11-year-old). Instruments included a test, that is accompanied by Certainty Response Index (CRI) and interview with students and teacher. The result of the test has been obtained, then processed by analyzing the student’s answers for each item and then grouped by the CRI categories that combined with the results of the interview with students and teacher. The results showed that student’s mastery-concept on additional and subtraction dominated by category ‘misconception’. So, we can say that mastery-concept on addition and subtraction of fraction at fifth-grade students is still low. Finally, the impact can make most of primary student think that learning addition and subtraction of fraction in mathematics is difficult.

  11. Infinity subtraction in a quantum field theory of charges and monopoles

    International Nuclear Information System (INIS)

    Panagiotakopoulos, C.

    1982-03-01

    Subtraction of ultraviolet infinities in Zwanziger's local quantum field theory of charges and monopoles is described. It involves an infinite number of graphs. The whole programme rests on the assumption that the infinite summations involved do not give rise to pathological situations and the Ward identities are satisfied even after the string cancellations. The resulting finite theory is Lorentz invariant. (author)

  12. Dissociation of Subtraction and Multiplication in the Right Parietal Cortex: Evidence from Intraoperative Cortical Electrostimulation

    Science.gov (United States)

    Yu, Xiaodan; Chen, Chuansheng; Pu, Song; Wu, Chenxing; Li, Yongnian; Jiang, Tao; Zhou, Xinlin

    2011-01-01

    Previous research has consistently shown that the left parietal cortex is critical for numerical processing, but the role of the right parietal lobe has been much less clear. This study used the intraoperative cortical electrical stimulation approach to investigate neural dissociation in the right parietal cortex for subtraction and…

  13. Application of digital subtraction angiography in disease of large cardiac vessel

    Energy Technology Data Exchange (ETDEWEB)

    Arisawa, Jun; Sone, Shusuke; Morimoto, Shizuo; Ikezoe, Junpei; Higashibara, Tokuro; Hanayama, Masayuki

    1983-06-01

    Digital subtraction angiography (DSA) was performed in 31 cases of disease of large cardiac vessel. DSA was useful for the diagnosis of aortic aneurysm and malformation of large vessels, follow-up after A-C bypass operation and Blalock's shunt operation for tetralogy of Fallot and as an adjuvant modality in cardiac catheterization.

  14. Application of digital subtraction angiography in disease of large cardiac vessel

    International Nuclear Information System (INIS)

    Arisawa, Jun; Sone, Shusuke; Morimoto, Shizuo; Ikezoe, Junpei; Higashibara, Tokuro; Hanayama, Masayuki

    1983-01-01

    Digital subtraction angiography (DSA) was performed in 31 cases of disease of large cardiac vessel. DSA was useful for the diagnosis of aortic aneurysm and malformation of large vessels, follow-up after A-C bypass operation and Blalock's shunt operation for tetralogy of Fallot and as an adjuvant modality in cardiac catheterization. (Chiba, N.)

  15. [X-ray semiotics of sialolithiasis in functional digital subtraction sialography].

    Science.gov (United States)

    Iudin, L A; Kondrashin, S A; Afanas'ev, V V; Shchipskiĭ, A V

    1995-01-01

    Twenty-seven patients with sialolithiasis were examined using functional subtraction sialography developed by the authors. Differential diagnostic signs characterizing the degree of involvement of the salivary gland were defined. High efficacy of the method helps correctly plan the treatment strategy.

  16. On Semiotics and Jumping Frogs: The Role of Gesture in the Teaching of Subtraction

    Science.gov (United States)

    Farrugia, Marie Therese

    2017-01-01

    In this article, I describe a research/teaching experience I undertook with a class of 5-year-old children in Malta. The topic was subtraction on the number line. I interpret the teaching/learning process through a semiotic perspective. In particular, I highlight the role played by the gesture of forming "frog jumps" on the number line.…

  17. The role of contrast-enhanced digital subtraction MRI in the diagnosis of vertebral metastasic tumors

    International Nuclear Information System (INIS)

    Xiao Yeyu; Yang Jun; Qi Weili; Liu Qize; Hong Bikai; Wu Renhua

    2008-01-01

    Objective: To evaluate the contrast-enhanced digital subtraction MRI in the diagnosis of vertebral metastasic tumors. Methods 66 vertebral metastasic tumors in 43 patients were examined with conventional MRI (T 1 WI, STIR and Contrast-enhanced T 1 WI) and contrast-enhanced digital subtraction MR imaging. All lesions were histologically proved. The quantity and characteristic imaging signs (including spiculation, bull eye sign and irregular edge) of lesions were detected separately by different sequences. K independent samples test was used. Results: The detection rates of 35 vertebral metastasic tumors with vertebral morphological changes were same in all MR sequences. But in the other 31 lesions without vertebral morphological changes, the detection rates were different and STIR was the highest in all sequences. Contrast-enhanced digital subtraction MRI was more sensitive than all the conventional MR sequences in finding characteristic imaging signs with statistically significant differences. Conclusion: Contrast enhanced subtraction MRI is an useful and convenient technique which has great value in finding vertebral metastasic tumors and depicting the characteristic imaging signs. (authors)

  18. Geometrical accuracy of metallic objects produced with additive or subtractive manufacturing: A comparative in vitro study.

    Science.gov (United States)

    Braian, Michael; Jönsson, David; Kevci, Mir; Wennerberg, Ann

    2018-04-06

    To evaluate the accuracy and precision of objects produced by additive manufacturing systems (AM) for use in dentistry and to compare with subtractive manufacturing systems (SM). Ten specimens of two geometrical objects were produced by five different AM machines and one SM machine. Object A mimics an inlay-shaped object, while object B imitates a four-unit bridge model. All the objects were sorted into different measurement dimensions (x, y, z), linear distances, angles and corner radius. None of the additive manufacturing or subtractive manufacturing groups presented a perfect match to the CAD file with regard to all parameters included in the present study. Considering linear measurements, the precision for subtractive manufacturing group was consistent in all axes for object A, presenting results of additive manufacturing groups had consistent precision in the x-axis and y-axis but not in the z-axis. With regard to corner radius measurements, the SM group had the best overall accuracy and precision for both objects A and B when compared to the AM groups. Within the limitations of this in vitro study, the conclusion can be made that subtractive manufacturing presented overall precision on all measurements below 0.050mm. The AM machines also presented fairly good precision, additive techniques are now being implemented. Thus all these production techniques need to be tested, compared and validated. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

  19. Addition and Subtraction but Not Multiplication and Division Cause Shifts of Spatial Attention

    Directory of Open Access Journals (Sweden)

    Mengjin Li

    2018-05-01

    Full Text Available Many studies have shown that solving addition and subtraction problems can induce overt shifts of spatial attention. In particular, right-side targets are detected faster than left-side targets when preceded by an addition operation, while left-side targets are detected faster than right-side targets when preceded by a subtraction operation. However, the interaction between space and arithmetic in multiplication or division is hardly studied and remains controversial. In order to make a strong case for the interaction between space and mental arithmetic, we attempted to replicate the spatial-arithmetic association in addition and subtraction (Experiment 1, and at the same time investigated whether shift of spatial attention would also be induced by multiplication or division operations (Experiment 2. We found that solving addition problems facilitated the detection of right-side targets, whereas left-side targets were detected faster after solving subtraction problems. However, no interaction between space and arithmetic operation was observed in multiplication or division. The implication of these findings is discussed.

  20. Non-perturbative subtractions in the heavy quark effective field theory

    International Nuclear Information System (INIS)

    Maiani, L.; Martinelli, G.; Sachrajda, C.T.

    1992-01-01

    We demonstrate the presence of ultraviolet power divergences in the O(1/m h ) corrections to matrix elements of hadronic operators containing a heavy quark field (where m h is the mass of the heavy quark). These power divergences must be subtracted non-perturbatively. The implications for lattice computations are discussed in detail. (orig.)

  1. Digital subtraction angiography and intraarterial contrast medium injection for coronary examinations

    Energy Technology Data Exchange (ETDEWEB)

    Tobio, R; Kallmeyer, C; Castello, J

    1985-01-01

    Digital subtraction angiography (DSA) is an established method of vasography, most extensively used as i.v. DSA. Intraarterial injection, however, applying selective or non-selective contrast medium injection, seems to be at least as important a technique although it has not yet met with corresponding interest. The article explains advantages of the technique for angiographic examinations, in particular of coronary angiography.

  2. Digital subtraction angiography - a new approach to brain death determination in the newborn

    International Nuclear Information System (INIS)

    Albertini, A.; Schonfeld, S.; Hiatt, M.; Hegyi, T.

    1993-01-01

    The diagnosis of brain death in the newborn infants is elusive and often difficult. The lack of cerebral blood flow has become an identified criterion for loss of cerebral function. The diagnosis can be obtained by the technique of digital subtraction angiography, which is presented in two case reports demonstrating the utility of this technique. (orig.)

  3. Heritage Language Learners in Mixed Spanish Classes: Subtractive Practices and Perceptions of High School Spanish Teachers

    Science.gov (United States)

    Randolph, Linwood J., Jr.

    2017-01-01

    This qualitative study investigated the language ideologies and instructional practices of an entire Spanish language faculty at a high school in a new gateway state for immigration. The study examined additive and subtractive practices of teachers as they strived to teach Spanish to heritage language learners (HLLs) enrolled in mixed…

  4. Does one see gluon condensation after subtraction of mean field perturbation theory from Monte Carlo data

    International Nuclear Information System (INIS)

    Schlichting, H.

    1985-01-01

    We do a linearised mean field calculation in axial gauge for the four dimensional mixed fundamental adjoint SU(2) lattice gauge theory and extract the gluon condensate parameter from the expectation values of the plaquette and the action by subtracting mean field perturbation theory from Monte Carlo data. (orig.)

  5. Low-cost addition-subtraction sequences for the final exponentiation computation in pairings

    DEFF Research Database (Denmark)

    Guzmán-Trampe, Juan E; Cruz-Cortéz, Nareli; Dominguez Perez, Luis

    2014-01-01

    In this paper, we address the problem of finding low cost addition–subtraction sequences for situations where a doubling step is significantly cheaper than a non-doubling one. One application of this setting appears in the computation of the final exponentiation step of the reduced Tate pairing d...

  6. Proximal caries detection using digital subtraction radiography in the artificial caries activity model

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Hoon; Lee, Gi Ja; Choi, Sam Jin; Park, Young Ho; Kim, Kyung Soo; Jin, Hyun Seok; Hong, Kyung Won; Oh, Berm Seok; Park, Hun Kuk [Department of Biomedical Engineering, School of Medicine, Kyung Hee University, Seoul (Korea, Republic of); Choi, Yong Suk; Hwang, Eui Hwan [Department of Oral and Maxillofacial Radiology, Institute of Oral Biology, School of Dentistry, Kyung Hee University, Seoul (Korea, Republic of)

    2009-03-15

    The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model. Digital radiographs of five teeth with 8 proximal surfaces were obtained by CCD sensor (Kodak RVG 6100 using a size no.2). The digital radiographic images and subtraction images from artificial proximal caries were examined and interpreted. In this study, we proposed novel caries detection method which could diagnose the dental proximal caries from single digital radiographic image. In artificial caries activity model, the range of lesional depth was 572-1,374 {mu}m and the range of lesional area was 36.95-138.52 mm{sup 2}. The lesional depth and the area were significantly increased with demineralization time (p<0.001). Furthermore, the proximal caries detection using digital subtraction radiography showed high detection rate compared to the proximal caries examination using simple digital radiograph. The results demonstrated that the digital subtraction radiography from single radiographic image of artificial caries was highly efficient in the detection of dental caries compared to the data from simple digital radiograph.

  7. Proximal caries detection using digital subtraction radiography in the artificial caries activity model

    International Nuclear Information System (INIS)

    Park, Jong Hoon; Lee, Gi Ja; Choi, Sam Jin; Park, Young Ho; Kim, Kyung Soo; Jin, Hyun Seok; Hong, Kyung Won; Oh, Berm Seok; Park, Hun Kuk; Choi, Yong Suk; Hwang, Eui Hwan

    2009-01-01

    The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model. Digital radiographs of five teeth with 8 proximal surfaces were obtained by CCD sensor (Kodak RVG 6100 using a size no.2). The digital radiographic images and subtraction images from artificial proximal caries were examined and interpreted. In this study, we proposed novel caries detection method which could diagnose the dental proximal caries from single digital radiographic image. In artificial caries activity model, the range of lesional depth was 572-1,374 μm and the range of lesional area was 36.95-138.52 mm 2 . The lesional depth and the area were significantly increased with demineralization time (p<0.001). Furthermore, the proximal caries detection using digital subtraction radiography showed high detection rate compared to the proximal caries examination using simple digital radiograph. The results demonstrated that the digital subtraction radiography from single radiographic image of artificial caries was highly efficient in the detection of dental caries compared to the data from simple digital radiograph.

  8. Pediatric head and neck lesions: assessment of vascularity by MR digital subtraction angiography.

    Science.gov (United States)

    Chooi, Weng Kong; Woodhouse, Neil; Coley, Stuart C; Griffiths, Paul D

    2004-08-01

    Pediatric head and neck lesions can be difficult to characterize on clinical grounds alone. We investigated the use of dynamic MR digital subtraction angiography as a noninvasive adjunct for the assessment of the vascularity of these abnormalities. Twelve patients (age range, 2 days to 16 years) with known or suspected vascular abnormalities were studied. Routine MR imaging, time-of-flight MR angiography, and MR digital subtraction angiography were performed in all patients. The dynamic sequence was acquired in two planes at one frame per second by using a thick section (6-10 cm) selective radio-frequency spoiled fast gradient-echo sequence and an IV administered bolus of contrast material. The images were subtracted from a preliminary mask sequence and viewed as a video-inverted cine loop. In all cases, MR digital subtraction angiography was successfully performed. The technique showed the following: 1) slow flow lesions (two choroidal angiomas, eyelid hemangioma, and scalp venous malformation); 2) high flow lesions that were not always suspected by clinical examination alone (parotid hemangioma, scalp, occipital, and eyelid arteriovenous malformations plus a palatal teratoma); 3) a hypovascular tumor for which a biopsy could be safely performed (Burkitt lymphoma); and 4) a hypervascular tumor of the palate (cystic teratoma). Our early experience suggests that MR digital subtraction angiography can be reliably performed in children of all ages without complication. The technique provided a noninvasive assessment of the vascularity of each lesion that could not always have been predicted on the basis of clinical examination or routine MR imaging alone.

  9. Evaluation of carotid vessel wall enhancement with image subtraction after gadobenate dimeglumine-enhanced MR angiography

    International Nuclear Information System (INIS)

    Sardanelli, Francesco; Di Leo, Giovanni; Aliprandi, Alberto; Flor, Nicola; Papini, Giacomo D.E.; Roccatagliata, Luca; Cotticelli, Biagio; Nano, Giovanni; Cornalba, Gianpaolo

    2009-01-01

    Objectives: This study was aimed at testing the value of image subtraction for evaluating carotid vessel wall enhancement in contrast-enhanced MR angiography (MRA). Materials and methods: IRB approval was obtained. The scans of 81 consecutive patients who underwent carotid MRA with 0.1 mmol/kg of gadobenate dimeglumine were reviewed. Axial carotid 3D T1-weighted fast low-angle shot sequence before and 3 min after contrast injection were acquired and subtracted (enhanced minus unenhanced). Vessel wall enhancement was assigned a four-point score using native or subtracted images from 0 (no enhancement) to 3 (strong enhancement). Stenosis degree was graded according to NASCET. Results: With native images, vessel wall enhancement was detected in 20/81 patients (25%) and in 20/161 carotids (12%), and scored 2.0 ± 0.6 (mean ± standard deviation); with subtracted images, in 21/81 (26%) and 22/161 (14%), and scored 2.5 ± 0.6, respectively (P < 0.001, Sign test). The overall stenosis degree distribution was: mild, 41/161 (25%); moderate, 77/161 (48%); severe, 43/161 (27%). Carotids with moderate stenosis showed vessel wall enhancement with a frequency (17/77, 22%) significantly higher than that observed in carotids with mild stenosis (1/41, 2%) (P = 0.005, Fisher exact test) and higher, even though with borderline significance (P = 0.078, Fisher exact test), than that observed in carotids with severe stenosis (4/43, 9%). Conclusion: Roughly a quarter of patients undergoing carotid MRA showed vessel wall enhancement. Image subtraction improved vessel wall enhancement conspicuity. Vessel wall enhancement seems to be an event relatively independent from the degree of stenosis. Further studies are warranted to define the relation between vessel wall enhancement and histopathology, inflammatory status, and instability.

  10. [Frontier in bone biology].

    Science.gov (United States)

    Takeda, Shu

    2015-10-01

    Bone is an active organ in which bone mass is maintained by the balance between osteoblastic bone formation and osteoclastic bone resorption, i.e., coupling of bone formation and bone resorption. Recent advances in molecular bone biology uncovered the molecular mechanism of the coupling. A fundamental role of osteocyte in the maintenance of bone mass and whole body metabolism has also been revealed recently. Moreover, neurons and neuropeptides have been shown to be intimately involved in bone homeostasis though inter-organ network, in addition to "traditional" regulators of bone metabolism such as soluble factors and cytokines

  11. Nonenhanced magnetic resonance angiography (MRA) of the calf arteries at 3 Tesla: intraindividual comparison of 3D flow-dependent subtractive MRA and 2D flow-independent non-subtractive MRA.

    Science.gov (United States)

    Knobloch, Gesine; Lauff, Marie-Teres; Hirsch, Sebastian; Schwenke, Carsten; Hamm, Bernd; Wagner, Moritz

    2016-12-01

    To prospectively compare 3D flow-dependent subtractive MRA vs. 2D flow-independent non-subtractive MRA for assessment of the calf arteries at 3 Tesla. Forty-two patients with peripheral arterial occlusive disease underwent nonenhanced MRA of calf arteries at 3 Tesla with 3D flow-dependent subtractive MRA (fast spin echo sequence; 3D-FSE-MRA) and 2D flow-independent non-subtractive MRA (balanced steady-state-free-precession sequence; 2D-bSSFP-MRA). Moreover, all patients underwent contrast-enhanced MRA (CE-MRA) as standard-of-reference. Two readers performed a per-segment evaluation for image quality (4 = excellent to 0 = non-diagnostic) and severity of stenosis. Image quality scores of 2D-bSSFP-MRA were significantly higher compared to 3D-FSE-MRA (medians across readers: 4 vs. 3; p Tesla with significantly higher image quality and diagnostic accuracy compared to 3D flow-dependent subtractive MRA (3D-FSE-MRA). • 2D flow-independent non-subtractive MRA (2D-bSSFP-MRA) is a robust NE-MRA technique at 3T • 2D-bSSFP-MRA outperforms 3D flow-dependent subtractive MRA (3D-FSE-MRA) as NE-MRA of calf arteries • 2D-bSSFP-MRA is a promising alternative to CE-MRA for calf PAOD evaluation.

  12. A comparative study of additive and subtractive manufacturing for dental restorations.

    Science.gov (United States)

    Bae, Eun-Jeong; Jeong, Il-Do; Kim, Woong-Chul; Kim, Ji-Hwan

    2017-08-01

    Digital systems have recently found widespread application in the fabrication of dental restorations. For the clinical assessment of dental restorations fabricated digitally, it is necessary to evaluate their accuracy. However, studies of the accuracy of inlay restorations fabricated with additive manufacturing are lacking. The purpose of this in vitro study was to evaluate and compare the accuracy of inlay restorations fabricated by using recently introduced additive manufacturing with the accuracy of subtractive methods. The inlay (distal occlusal cavity) shape was fabricated using 3-dimensional image (reference data) software. Specimens were fabricated using 4 different methods (each n=10, total N=40), including 2 additive manufacturing methods, stereolithography apparatus and selective laser sintering; and 2 subtractive methods, wax and zirconia milling. Fabricated specimens were scanned using a dental scanner and then compared by overlapping reference data. The results were statistically analyzed using a 1-way analysis of variance (α=.05). Additionally, the surface morphology of 1 randomly (the first of each specimen) selected specimen from each group was evaluated using a digital microscope. The results of the overlap analysis of the dental restorations indicated that the root mean square (RMS) deviation observed in the restorations fabricated using the additive manufacturing methods were significantly different from those fabricated using the subtractive methods (Padditive manufacturing methods (P=.466). Similarly, no significant differences were found between wax and zirconia, the subtractive methods (P=.986). The observed RMS values were 106 μm for stereolithography apparatus, 113 μm for selective laser sintering, 116 μm for wax, and 119 μm for zirconia. Microscopic evaluation of the surface revealed a fine linear gap between the layers of restorations fabricated using stereolithography apparatus and a grooved hole with inconsistent weak scratches

  13. Constructive Technology Assessment (CTA) as a tool in coverage with evidence development: the case of the 70-gene prognosis signature for breast cancer diagnostics.

    Science.gov (United States)

    Retèl, Valesca P; Bueno-de-Mesquita, Jolien M; Hummel, Marjan J M; van de Vijver, Marc J; Douma, Kirsten F L; Karsenberg, Kim; van Dam, Frits S A M; van Krimpen, Cees; Bellot, Frank E; Roumen, Rudi M H; Linn, Sabine C; van Harten, Wim H

    2009-01-01

    Constructive Technology Assessment (CTA) is a means to guide early implementation of new developments in society, and can be used as an evaluation tool for Coverage with Evidence Development (CED). We used CTA for the introduction of a new diagnostic test in the Netherlands, the 70-gene prognosis signature (MammaPrint) for node-negative breast cancer patients. Studied aspects were (organizational) efficiency, patient-centeredness and diffusion scenarios. Pre-post structured surveys were conducted in fifteen community hospitals concerning changes in logistics and teamwork as a consequence of the introduction of the 70-gene signature. Patient-centeredness was measured by questionnaires and interviews regarding knowledge and psychological impact of the test. Diffusion scenarios, which are commonly applied in industry to anticipate on future development and diffusion of their products, have been applied in this study. Median implementation-time of the 70-gene signature was 1.2 months. Most changes were seen in pathology processes and adjuvant treatment decisions. Physicians valued the addition of the 70-gene signature information as beneficial for patient management. Patient-centeredness (n = 77, response 78 percent): patients receiving a concordant high-risk and discordant clinical low/high risk-signature showed significantly more negative emotions with respect to receiving both test-results compared with concordant low-risk and discordant clinical high/low risk-signature patients. The first scenario was written in 2004 before the introduction of the 70-gene signature and identified hypothetical developments that could influence diffusion; especially the "what-if" deviation describing a discussion on validity among physicians proved to be realistic. Differences in speed of implementation and influenced treatment decisions were seen. Impact on patients seems especially related to discordance and its successive communication. In the future, scenario drafting will lead

  14. Dating of cremated bones

    NARCIS (Netherlands)

    Lanting, JN; Aerts-Bijma, AT; van der Plicht, J; Boaretto, E.; Carmi, I.

    2001-01-01

    When dating unburnt bone, bone collagen, the organic fraction of the bone, is used. Collagen does not survive the heat of the cremation pyre, so dating of cremated bone has been considered impossible. Structural carbonate in the mineral fraction of the bone, however, survives the cremation process.

  15. Improvement in visibility of simulated lung nodules on computed radiography (CR) chest images by use of temporal subtraction technique

    International Nuclear Information System (INIS)

    Oda, Nobuhiro; Fujimoto, Keiji; Murakami, Seiichi; Katsuragawa, Shigehiko; Doi, Kunio; Nakata, Hajime

    1999-01-01

    A temporal subtraction image obtained by subtraction of a previous image from a current one can enhance interval change on chest images. In this study, we compared the visibility of simulated lung nodules on CR images with and without temporal subtraction. Chest phantom images without and with simulated nodules were obtained as previous and current images, respectively, by a CR system. Then, subtraction images were produced with an iterative image warping technique. Twelve simulated nodules were attached on various locations of the chest phantom. The diameter of nodules having a CT number of 47 ranged from 3 mm to 10 mm. Seven radiologists subjectively evaluated the visibility of simulated nodules on CR images with and without temporal subtraction using a three-point rating scale (0: invisible, +1: questionable, +2:visible). The minimum diameter of simulated nodules visible at a frequency greater than 50% was 4 mm on the CR images with temporal subtraction and 6 mm on those without. Our results indicated that the subtraction images clearly improved the visibility of simulated nodules. (author)

  16. [Construction of forward and reverse subtracted cDNA libraries between muscle tissue of Meishan and Landrace pigs].

    Science.gov (United States)

    Xu, De-Quan; Zhang, Yi-Bing; Xiong, Yuan-Zhu; Gui, Jian-Fang; Jiang, Si-Wen; Su, Yu-Hong

    2003-07-01

    Using suppression subtractive hybridization (SSH) technique, forward and reverse subtracted cDNA libraries were constructed between Longissimus muscles from Meishan and Landrace pigs. A housekeeping gene, G3PDH, was used to estimate the efficiency of subtractive cDNA. In two cDNA libraries, G3PDH was subtracted very efficiently at appropriate 2(10) and 2(5) folds, respectively, indicating that some differentially expressed genes were also enriched at the same folds and the two subtractive cDNA libraries were very successful. A total of 709 and 673 positive clones were isolated from forward and reverse subtracted cDNA libraries, respectively. Analysis of PCR showed that most of all plasmids in the clones contained 150-750 bp inserts. The construction of subtractive cDNA libraries between muscle tissue from different pig breeds laid solid foundations for isolating and identifying the genes determining muscle growth and meat quality, which will be important to understand the mechanism of muscle growth, determination of meat quality and practice of molecular breeding.

  17. Relation between thallium-201/iodine 123-BMIPP subtraction and fluorine 18 deoxyglucose polar maps in patients with hypertrophic cardiomyopathy.

    Science.gov (United States)

    Ito, Y; Hasegawa, S; Yamaguchi, H; Yoshioka, J; Uehara, T; Nishimura, T

    2000-01-01

    Clinical studies have shown discrepancies in the distribution of thallium-201 and iodine 123-beta-methyl-iodophenylpentadecanoic acid (BMIPP) in patients with hypertrophic cardiomyopathy (HCM). Myocardial uptake of fluorine 18 deoxyglucose (FDG) is increased in the hypertrophic area in HCM. We examined whether the distribution of a Tl-201/BMIPP subtraction polar map correlates with that of an FDG polar map. We normalized to maximum count each Tl-201 and BMIPP bull's-eye polar map of 6 volunteers and obtained a standard Tl-201/BMIPP subtraction polar map by subtracting a normalized BMIPP bull's-eye polar map from a normalized Tl-201 bull's-eye polar map. The Tl-201/BMIPP subtraction polar map was then applied to 8 patients with HCM (mean age 65+/-12 years) to evaluate the discrepancy between Tl-201 and BMIPP distribution. We compared the Tl-201/BMIPP subtraction polar map with an FDG polar map. In patients with HCM, the Tl-201/BMIPP subtraction polar map showed a focal uptake pattern in the hypertrophic area similar to that of the FDG polar map. By quantitative analysis, the severity score of the Tl-201/BMIPP subtraction polar map was significantly correlated with the percent dose uptake of the FDG polar map. These results suggest that this new quantitative method may be an alternative to FDG positron emission tomography for the routine evaluation of HCM.

  18. Suppression subtractive hybridization as a tool to identify anthocyanin metabolism-related genes in apple skin.

    Science.gov (United States)

    Ban, Yusuke; Moriguchi, Takaya

    2010-01-01

    The pigmentation of anthocyanins is one of the important determinants for consumer preference and marketability in horticultural crops such as fruits and flowers. To elucidate the mechanisms underlying the physiological process leading to the pigmentation of anthocyanins, identification of the genes differentially expressed in response to anthocyanin accumulation is a useful strategy. Currently, microarrays have been widely used to isolate differentially expressed genes. However, the use of microarrays is limited by its high cost of special apparatus and materials. Therefore, availability of microarrays is limited and does not come into common use at present. Suppression subtractive hybridization (SSH) is an alternative tool that has been widely used to identify differentially expressed genes due to its easy handling and relatively low cost. This chapter describes the procedures for SSH, including RNA extraction from polysaccharides and polyphenol-rich samples, poly(A)+ RNA purification, evaluation of subtraction efficiency, and differential screening using reverse northern in apple skin.

  19. Digital video subtraction fluorography (DVSF) in the diagnosis of bronchial abnormality associated with congenital heart diseases

    International Nuclear Information System (INIS)

    Sano, Tetsuya; Arisawa, Jun; Nakajima, Toru

    1990-01-01

    To assess bronchial morphology and abnormality, 14 children with congenital heart diseases including 2 postoperative patients (age, 2 m.-4 yr) were studied by digital video subtraction fluorography (DVSF) using digital subtraction and image processing system (Philips, DVI-2). This newly developed technique clearly defined bronchial anatomy in all 14 patients. Bronchial situs could be determined in all 8 patients with complex heart anomalies. Out of 8 patients with respiratory distress in this study, obvious bronchial stenosis or obstruction was found by DVSF in 5 patients. Thus, DVSF image defined anatomies of main and lobar bronchi more clearly than previous noninvasive methods. Moreover, DVSF is noninvasive and easily performed even for small infants and critically ill patients. In conclusion, DVSF may be a useful technique to assess bronchial morphology and abnormality in patients with congenital heart diseases. (author)

  20. Increasing LIGO sensitivity by feedforward subtraction of auxiliary length control noise

    International Nuclear Information System (INIS)

    Meadors, Grant David; Riles, Keith; Kawabe, Keita

    2014-01-01

    LIGO, the Laser Interferometer Gravitational-wave Observatory, has been designed and constructed to measure gravitational wave strain via differential arm length. The LIGO 4 km Michelson arms with Fabry–Perot cavities have auxiliary length control servos for suppressing Michelson motion of the beam-splitter and arm cavity input mirrors, which degrades interferometer sensitivity. We demonstrate how a post facto pipeline improves a data sample from LIGO Science Run 6 with feedforward subtraction. Dividing data into 1024 s windows, we numerically fit filter functions representing the frequency-domain transfer functions from Michelson length channels into the gravitational-wave strain data channel for each window, then subtract the filtered Michelson channel noise (witness) from the strain channel (target). In this paper we describe the algorithm, assess achievable improvements in sensitivity to astrophysical sources, and consider relevance to future interferometry. (paper)