WorldWideScience

Sample records for bone plates

  1. Finite element analysis of functionally graded bone plate at femur bone fracture site

    Science.gov (United States)

    Satapathy, Pravat Kumar; Sahoo, Bamadev; Panda, L. N.; Das, S.

    2018-03-01

    This paper focuses on the analysis of fractured Femur bone with functionally graded bone plate. The Femur bone is modeled by using the data from the CT (Computerized Tomography) scan and the material properties are assigned using Mimics software. The fracture fixation plate used here is composed of Functionally Graded Material (FGM). The functionally graded bone plate is considered to be composed of different layers of homogeneous materials. Finite element method approach is adopted for analysis. The volume fraction of the material is calculated by considering its variation along the thickness direction (z) according to a power law and the effective properties of the homogeneous layers are estimated. The model developed is validated by comparing numerical results available in the literature. Static analysis has been performed for the bone plate system by considering both axial compressive load and torsional load. The investigation shows that by introducing FG bone plate instead of titanium, the stress at the fracture site increases by 63 percentage and the deformation decreases by 15 percentage, especially when torsional load is taken into consideration. The present model yields better results in comparison with the commercially available bone plates.

  2. Epiphyseal plate closure of radio-ulna bone in red Sokoto goat ...

    African Journals Online (AJOL)

    The radiographs of their forearms were taken and the proximal and distal epiphyseal plate lengths of both radius and ulna bones were measured. The radiographic images of the bones showed that the proximal and distal epiphyseal plates of the radius were opened at week 1 with mean lengths of 0.50±0.05mm and ...

  3. [Reconstruction of periprosthetic fractures of hip with cortical bone plates allografts].

    Science.gov (United States)

    Zhou, Zong-ke; Pei, Fu-xing; Tu, Chong-qi; Yang, Jing; Shen, Bin; Liu, Lei; Fatou, Camara-yagouba

    2004-12-22

    To observe clinical results for reconstruction of periprosthetic fractures of hip with cortical bone plates allografts by deep-freezing and ethylene oxide treatment. Seven patients with periprosthetic fractures of hip underwent cortical bone plates allografts by deep-freezing at -70 degrees C after being treatment of 48 degrees C ethylene oxide. And evaluate clinical outcome by examining T lymphocytes, Harris scores, X-rays photograph, and bone scintigraphy. There were not activity of immune rejection and infection in all patients. Harris scores of patients increased 21, 32, 40, 40 scores at 3, 6, 12, 24 months after surgery. T-lymphocytes, antibody and immunocomplex in blood was normal postoperation. X-ray film indicated that fracture was healed at 3 months and there was partially bone conjunction between allograft strut and host bone. There was incorporation of 85% allograft strut to host bone, and 15% allograft strut was partially absorbed at 12 months after surgery. The size of femur of host was added 3 mm to 5 mm, averaged 4.3 mm at 12 months postoperation. Density of 80% allograft plates was as same as host bone after remodeling and the absorbtion of 10% allograft plates stopped at 24 months after surgery. There was thick of nuclein in the area of allograft cortical bone plates by bone scintigraphy examination at 3 months postoperation, and the thick of nuclein was stronger at 6, and 12 months after surgery. Allograft cortical bone plates by deep frozen at -70 degrees C after being treatment of 48 degrees C ethylene oxide is suitable for mechanical fixation and biological bone transplantation, and it can increase bone reservation, augment strength of femur once the allograft strut incorporates to host bone, and avoid removing metal implant in second operation when being applied into reconstruction femoral fracture in joint replacement.

  4. Use of 3D Printed Bone Plate in Novel Technique to Surgically Correct Hallux Valgus Deformities

    Science.gov (United States)

    Smith, Kathryn E.; Dupont, Kenneth M.; Safranski, David L.; Blair, Jeremy; Buratti, Dawn; Zeetser, Vladimir; Callahan, Ryan; Lin, Jason; Gall, Ken

    2016-01-01

    Three-dimensional (3-D) printing offers many potential advantages in designing and manufacturing plating systems for foot and ankle procedures that involve small, geometrically complex bony anatomy. Here, we describe the design and clinical use of a Ti-6Al-4V ELI bone plate (FastForward™ Bone Tether Plate, MedShape, Inc., Atlanta, GA) manufactured through 3-D printing processes. The plate protects the second metatarsal when tethering suture tape between the first and second metatarsals and is a part of a new procedure that corrects hallux valgus (bunion) deformities without relying on doing an osteotomy or fusion procedure. The surgical technique and two clinical cases describing the use of this procedure with the 3-D printed bone plate are presented within. PMID:28337049

  5. Use of 3D Printed Bone Plate in Novel Technique to Surgically Correct Hallux Valgus Deformities.

    Science.gov (United States)

    Smith, Kathryn E; Dupont, Kenneth M; Safranski, David L; Blair, Jeremy; Buratti, Dawn; Zeetser, Vladimir; Callahan, Ryan; Lin, Jason; Gall, Ken

    2016-09-01

    Three-dimensional (3-D) printing offers many potential advantages in designing and manufacturing plating systems for foot and ankle procedures that involve small, geometrically complex bony anatomy. Here, we describe the design and clinical use of a Ti-6Al-4V ELI bone plate (FastForward™ Bone Tether Plate, MedShape, Inc., Atlanta, GA) manufactured through 3-D printing processes. The plate protects the second metatarsal when tethering suture tape between the first and second metatarsals and is a part of a new procedure that corrects hallux valgus (bunion) deformities without relying on doing an osteotomy or fusion procedure. The surgical technique and two clinical cases describing the use of this procedure with the 3-D printed bone plate are presented within.

  6. Comparison of the effect on bone healing process of different implants used in minimally invasive plate osteosynthesis: limited contact dynamic compression plate versus locking compression plate.

    Science.gov (United States)

    Xue, Zichao; Xu, Haitao; Ding, Haoliang; Qin, Hui; An, Zhiquan

    2016-11-25

    Minimally invasive plate osteosynthesis (MIPO) has been widely accepted because of its satisfactory clinical outcomes. However, the implant construct that works best for MIPO remains controversial. Different plate designs result in different influence mechanisms to blood flow. In this study, we created ulnar fractures in 42 beagle dogs and fixed the fractures using MIPO. The dogs were randomly divided into two groups and were fixed with a limited contact dynamic compression plate (LC-DCP) or a locking compression plate (LCP). Our study showed that with MIPO, there was no significant difference between the LCP and the LC-DCP in terms of fracture fixation, bone formation, or mineralization. Combined with the previous literature, we inferred that the healing process is affected by the quality of fracture reduction more than plate selection.

  7. Evaluation on Bending Properties of Biomaterial GUM Metal Meshed Plates for Bone Graft Applications

    Science.gov (United States)

    Suzuki, Hiromichi; He, Jianmei

    2017-11-01

    There are three bone graft methods for bone defects caused by diseases such as cancer and accident injuries: Autogenous bone grafts, Allografts and Artificial bone grafts. In this study, meshed GUM Metal plates with lower elasticity, high strength and high biocompatibility are introduced to solve the over stiffness & weight problems of ready-used metal implants. Basic mesh shapes are designed and applied to GUM Metal plates using 3D CAD modeling tools. Bending properties of prototype meshed GUM Metal plates are evaluated experimentally and analytically. Meshed plate specimens with 180°, 120° and 60° axis-symmetrical types were fabricated for 3-point bending tests. The pseudo bending elastic moduli of meshed plate specimens obtained from 3-point bending test are ranged from 4.22 GPa to 16.07 GPa, within the elasticity range of natural cortical bones from 2.0 GPa to 30.0 GPa. Analytical approach method is validated by comparison with experimental and analytical results for evaluation on bending property of meshed plates.

  8. Customized a Ti6Al4V Bone Plate for Complex Pelvic Fracture by Selective Laser Melting.

    Science.gov (United States)

    Wang, Di; Wang, Yimeng; Wu, Shibiao; Lin, Hui; Yang, Yongqiang; Fan, Shicai; Gu, Cheng; Wang, Jianhua; Song, Changhui

    2017-01-04

    In pelvic fracture operations, bone plate shaping is challenging and the operation time is long. To address this issue, a customized bone plate was designed and produced using selective laser melting (SLM) technology. The key steps of this study included designing the customized bone plate, metal 3D printing, vacuum heat treatment, surface post-processing, operation rehearsal, and clinical application and evaluation. The joint surface of the bone plate was placed upwards with respect to the build platform to keep it away from the support and to improve the quality of the joint surface. Heat conduction was enhanced by adding a cone-type support beneath the bone plate to prevent low-quality fabrication due to poor heat conductivity of the Ti-6Al-4V powder. The residual stress was eliminated by exposing the SLM-fabricated titanium-alloy bone plate to a vacuum heat treatment. Results indicated that the bone plate has a hardness of HV1 360-HV1 390, an ultimate tensile strength of 1000-1100 MPa, yield strength of 900-950 MPa, and an elongation of 8%-10%. Pre-operative experiments and operation rehearsal were performed using the customized bone plate and the ABC-made pelvic model. Finally, the customized bone plate was clinically applied. The intraoperative C-arm and postoperative X-ray imaging results indicated that the customized bone plate matched well to the damaged pelvis. The customized bone plate fixed the broken bone and guides pelvis restoration while reducing operation time to about two hours. The customized bone plate eliminated the need for preoperative titanium plate pre-bending, thereby greatly reducing surgical wounds and operation time.

  9. Customized a Ti6Al4V Bone Plate for Complex Pelvic Fracture by Selective Laser Melting

    Directory of Open Access Journals (Sweden)

    Di Wang

    2017-01-01

    Full Text Available In pelvic fracture operations, bone plate shaping is challenging and the operation time is long. To address this issue, a customized bone plate was designed and produced using selective laser melting (SLM technology. The key steps of this study included designing the customized bone plate, metal 3D printing, vacuum heat treatment, surface post-processing, operation rehearsal, and clinical application and evaluation. The joint surface of the bone plate was placed upwards with respect to the build platform to keep it away from the support and to improve the quality of the joint surface. Heat conduction was enhanced by adding a cone-type support beneath the bone plate to prevent low-quality fabrication due to poor heat conductivity of the Ti-6Al-4V powder. The residual stress was eliminated by exposing the SLM-fabricated titanium-alloy bone plate to a vacuum heat treatment. Results indicated that the bone plate has a hardness of HV1 360–HV1 390, an ultimate tensile strength of 1000–1100 MPa, yield strength of 900–950 MPa, and an elongation of 8%–10%. Pre-operative experiments and operation rehearsal were performed using the customized bone plate and the ABC-made pelvic model. Finally, the customized bone plate was clinically applied. The intraoperative C-arm and postoperative X-ray imaging results indicated that the customized bone plate matched well to the damaged pelvis. The customized bone plate fixed the broken bone and guides pelvis restoration while reducing operation time to about two hours. The customized bone plate eliminated the need for preoperative titanium plate pre-bending, thereby greatly reducing surgical wounds and operation time.

  10. Minimally invasive plate augmentation in the treatment of long-bone non-unions.

    Science.gov (United States)

    Park, Ki-Chul; Oh, Chang-Wug; Kim, Joon-Woo; Park, Kyeong-Hyeon; Oh, Jong-Keon; Park, Il-Hyung; Kyung, Hee-Soo; Heo, Jeong

    2017-11-01

    Exchange nailing is most acceptable for treating hypertrophic non-union of the long bones, requiring the removal of previously fixed implant. However, its main effect of mechanical stabilization is controversial in non-isthmal area. We hypothesized that minimally invasive plate augmentation over the non-union site may have a better option, without the need of bone grafting or removing pre-existing implants. Seventeen patients with hypertrophic non-union of the long bones between 2010 and 2014 on radiography who previously underwent intramedullary (IM) nailing or plate osteosynthesis for long-bone fractures were included. A locking compression plate was inserted with at least three mono- or bicortical screws at each proximal and distal segment. Broken or loosened interlocking screws of IM nail were simultaneously re-fixed. Fracture site exposure, pre-fixed implant removal, and bone grafting were not performed. We investigated whether union occurred and analyzed functional outcomes and complications. Eleven femoral and six tibial non-unions were prospectively included. In the pre-existing implants, 13 nails and 4 plates were found. All cases achieved union at a mean 22.7 weeks. One case of superficial infection was managed with oral antibiotics. Deep infection or implant failure did not occur. Minimally invasive plate augmentation can achieve additional stability and promote healing of hypertrophic non-union of the long bones. When indicated, this technique is the least invasive alternative to exchange nailing and reduces surgical risks in the treatment of diaphyseal non-union.

  11. Accelerated growth plate mineralization and foreshortened proximal limb bones in fetuin-A knockout mice.

    Science.gov (United States)

    Seto, Jong; Busse, Björn; Gupta, Himadri S; Schäfer, Cora; Krauss, Stefanie; Dunlop, John W C; Masic, Admir; Kerschnitzki, Michael; Zaslansky, Paul; Boesecke, Peter; Catalá-Lehnen, Philip; Schinke, Thorsten; Fratzl, Peter; Jahnen-Dechent, Willi

    2012-01-01

    The plasma protein fetuin-A/alpha2-HS-glycoprotein (genetic symbol Ahsg) is a systemic inhibitor of extraskeletal mineralization, which is best underscored by the excessive mineral deposition found in various tissues of fetuin-A deficient mice on the calcification-prone genetic background DBA/2. Fetuin-A is known to accumulate in the bone matrix thus an effect of fetuin-A on skeletal mineralization is expected. We examined the bones of fetuin-A deficient mice maintained on a C57BL/6 genetic background to avoid bone disease secondary to renal calcification. Here, we show that fetuin-A deficient mice display normal trabecular bone mass in the spine, but increased cortical thickness in the femur. Bone material properties, as well as mineral and collagen characteristics of cortical bone were unaffected by the absence of fetuin-A. In contrast, the long bones especially proximal limb bones were severely stunted in fetuin-A deficient mice compared to wildtype littermates, resulting in increased biomechanical stability of fetuin-A deficient femora in three-point-bending tests. Elevated backscattered electron signal intensities reflected an increased mineral content in the growth plates of fetuin-A deficient long bones, corroborating its physiological role as an inhibitor of excessive mineralization in the growth plate cartilage matrix--a site of vigorous physiological mineralization. We show that in the case of fetuin-A deficiency, active mineralization inhibition is a necessity for proper long bone growth.

  12. Tensile behaviors of three-dimensionally free-formable titanium mesh plates for bone graft applications

    Science.gov (United States)

    He, Jianmei

    2017-11-01

    Present metal artificial bones for bone grafts have the problems like too heavy and excessive elastic modulus compared with natural bones. In this study, three-dimensionally (3D) free-formable titanium mesh plates for bone graft applications was introduced to improve these problems. Fundamental mesh shapes and patterns were designed under different base shapes and design parameters through three dimensional CAD tools from higher flexibility and strength points of view. Based on the designed mesh shape and patterns, sample specimens of titanium mesh plates with different base shapes and design variables were manufactured through laser processing. Tensile properties of the sample titanium mesh plates like volume density, tensile elastic modulus were experimentally and analytically evaluated. Experimental results showed that such titanium mesh plates had much higher flexibility and their mechanical properties could be controlled to close to the natural bones. More details on the mechanical properties of titanium mesh plates including compression, bending, torsion and durability will be carried out in future study.

  13. Nonunion of greater trochanter following total hip arthroplasty: Treated by an articulated hook plate and bone grafting

    Directory of Open Access Journals (Sweden)

    Diego L Fernandez

    2017-01-01

    Conclusions: The articulated design of the plate allows for ease in application and functional construct stability. The articulated hook plate is an option for fixation of osteopenic bone fragments and established nonunions of the greater trochanter.

  14. Resveratrol treatment delays growth plate fusion and improves bone growth in female rabbits.

    Directory of Open Access Journals (Sweden)

    Elham Karimian

    Full Text Available Trans-resveratrol (RES, naturally produced by many plants, has a structure similar to synthetic estrogen diethylstilbestrol, but any effect on bone growth has not yet been clarified. Pre-pubertal ovary-intact New Zealand white rabbits received daily oral administration of either vehicle (control or RES (200 mg/kg until growth plate fusion occurred. Bone growth and growth plate size were longitudinally monitored by X-ray imaging, while at the endpoint, bone length was assessed by a digital caliper. In addition, pubertal ovariectomized (OVX rabbits were treated with vehicle, RES or estradiol cypionate (positive control for 7 or 10 weeks and fetal rat metatarsal bones were cultured in vitro with RES (0.03 µM-50 µM and followed for up to 19 days. In ovary-intact rabbits, sixteen-week treatment with RES increased tibiae and vertebrae bone growth and subsequently improved final length. In OVX rabbits, RES delayed fusion of the distal tibia, distal femur and proximal tibia epiphyses and femur length and vertebral bone growth increased when compared with controls. Histomorphometrical analysis showed that RES-treated OVX rabbits had a wider distal femur growth plate, enlarged resting zone, increased number/size of hypertrophic chondrocytes, increased height of the hypertrophic zone, and suppressed chondrocyte expression of VEGF and laminin. In cultured fetal rat metatarsal bones, RES stimulated growth at 0.3 µM while at higher concentrations (10 μM and 50 μM growth was inhibited. We conclude that RES has the potential to improve longitudinal bone growth. The effect was associated with a delay of growth plate fusion resulting in increased final length. These effects were accompanied by a profound suppression of VEGF and laminin expression suggesting that impairment of growth plate vascularization might be an underlying mechanism.

  15. Cyp26b1 within the growth plate regulates bone growth in juvenile mice

    International Nuclear Information System (INIS)

    Minegishi, Yoshiki; Sakai, Yasuo; Yahara, Yasuhito; Akiyama, Haruhiko; Yoshikawa, Hideki; Hosokawa, Ko; Tsumaki, Noriyuki

    2014-01-01

    Highlights: • Retinoic acid and Cyp26b1 were oppositely localized in growth plate cartilage. • Cyp26b1 deletion in chondrocytes decreased bone growth in juvenile mice. • Cyp26b1 deletion reduced chondrocyte proliferation and growth plate height. • Vitamin A-depletion partially reversed growth plate abnormalities caused by Cyp26b1 deficiency. • Cyp26b1 regulates bone growth by controlling chondrocyte proliferation. - Abstract: Retinoic acid (RA) is an active metabolite of vitamin A and plays important roles in embryonic development. CYP26 enzymes degrade RA and have specific expression patterns that produce a RA gradient, which regulates the patterning of various structures in the embryo. However, it has not been addressed whether a RA gradient also exists and functions in organs after birth. We found localized RA activities in the diaphyseal portion of the growth plate cartilage were associated with the specific expression of Cyp26b1 in the epiphyseal portion in juvenile mice. To disturb the distribution of RA, we generated mice lacking Cyp26b1 specifically in chondrocytes (Cyp26b1 Δchon cKO). These mice showed reduced skeletal growth in the juvenile stage. Additionally, their growth plate cartilage showed decreased proliferation rates of proliferative chondrocytes, which was associated with a reduced height in the zone of proliferative chondrocytes, and closed focally by four weeks of age, while wild-type mouse growth plates never closed. Feeding the Cyp26b1 cKO mice a vitamin A-deficient diet partially reversed these abnormalities of the growth plate cartilage. These results collectively suggest that Cyp26b1 in the growth plate regulates the proliferation rates of chondrocytes and is responsible for the normal function of the growth plate and growing bones in juvenile mice, probably by limiting the RA distribution in the growth plate proliferating zone

  16. Cyp26b1 within the growth plate regulates bone growth in juvenile mice

    Energy Technology Data Exchange (ETDEWEB)

    Minegishi, Yoshiki [Department of Cell Growth and Differentiation, Center for iPS Cell Research and Application, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Department of Plastic and Reconstructive Surgery, University of Fukui Hospital, 23-3 Matsuokashimoaizuki, Eiheiji-cho, Yoshida-gun, Fukui 910-1193 (Japan); Department of Plastic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan); Sakai, Yasuo [Department of Plastic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan); Department of Plastic Surgery, Bellland General Hospital, 500-3 Higashiyama Naka-ku, Sakai, Osaka 599-8247 (Japan); Yahara, Yasuhito [Department of Cell Growth and Differentiation, Center for iPS Cell Research and Application, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Akiyama, Haruhiko [Department of Orthopaedic Surgery, Gifu University Graduate School of Medicine, 1-1 Yanagito, Gifu 501-1194 (Japan); Yoshikawa, Hideki [Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan); Hosokawa, Ko [Department of Plastic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan); Tsumaki, Noriyuki, E-mail: ntsumaki@cira.kyoto-u.ac.jp [Department of Cell Growth and Differentiation, Center for iPS Cell Research and Application, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Japan Science and Technology Agency, CREST, Tokyo 102-0075 (Japan)

    2014-11-07

    Highlights: • Retinoic acid and Cyp26b1 were oppositely localized in growth plate cartilage. • Cyp26b1 deletion in chondrocytes decreased bone growth in juvenile mice. • Cyp26b1 deletion reduced chondrocyte proliferation and growth plate height. • Vitamin A-depletion partially reversed growth plate abnormalities caused by Cyp26b1 deficiency. • Cyp26b1 regulates bone growth by controlling chondrocyte proliferation. - Abstract: Retinoic acid (RA) is an active metabolite of vitamin A and plays important roles in embryonic development. CYP26 enzymes degrade RA and have specific expression patterns that produce a RA gradient, which regulates the patterning of various structures in the embryo. However, it has not been addressed whether a RA gradient also exists and functions in organs after birth. We found localized RA activities in the diaphyseal portion of the growth plate cartilage were associated with the specific expression of Cyp26b1 in the epiphyseal portion in juvenile mice. To disturb the distribution of RA, we generated mice lacking Cyp26b1 specifically in chondrocytes (Cyp26b1{sup Δchon} cKO). These mice showed reduced skeletal growth in the juvenile stage. Additionally, their growth plate cartilage showed decreased proliferation rates of proliferative chondrocytes, which was associated with a reduced height in the zone of proliferative chondrocytes, and closed focally by four weeks of age, while wild-type mouse growth plates never closed. Feeding the Cyp26b1 cKO mice a vitamin A-deficient diet partially reversed these abnormalities of the growth plate cartilage. These results collectively suggest that Cyp26b1 in the growth plate regulates the proliferation rates of chondrocytes and is responsible for the normal function of the growth plate and growing bones in juvenile mice, probably by limiting the RA distribution in the growth plate proliferating zone.

  17. Patient-tailored plate for bone fixation and accurate 3D positioning in corrective osteotomy.

    Science.gov (United States)

    Dobbe, J G G; Vroemen, J C; Strackee, S D; Streekstra, G J

    2013-02-01

    A bone fracture may lead to malunion of bone segments, which gives discomfort to the patient and may lead to chronic pain, reduced function and finally to early osteoarthritis. Corrective osteotomy is a treatment option to realign the bone segments. In this procedure, the surgeon tries to improve alignment by cutting the bone at, or near, the fracture location and fixates the bone segments in an improved position, using a plate and screws. Three-dimensional positioning is very complex and difficult to plan, perform and evaluate using standard 2D fluoroscopy imaging. This study introduces a new technique that uses preoperative 3D imaging to plan positioning and design a patient-tailored fixation plate that only fits in one way and realigns the bone segments as planned. The method is evaluated using artificial bones and renders realignment highly accurate and very reproducible (d(err) < 1.2 ± 0.8 mm and φ(err) < 1.8° ± 2.1°). Application of a patient-tailored plate is expected to be of great value for future corrective osteotomy surgeries.

  18. A simplified application (APP) for the parametric design of screw-plate fixation of bone fractures.

    Science.gov (United States)

    Chung, Chen-Yuan

    2018-01-01

    Screw and plate fixation is commonly used to treat bone fractures. A prototype application (APP) for presurgical simulation was developed and validated by comparing it with current analytical approach and other models. In this APP, alternative plate designs and materials to limit the effects of stress shielding could be tested. In addition, the number and position of screws and the gap between bone and plate that achieved acceptable stability were predicted. The fixation stability providing a situation of interfragmentary strain between 2% and 10% is necessary for callus formation. However, improving the fixation stability leads to a stress shielding effect. The simultaneous alleviation of stress shielding and maintenance of stability are important in fracture healing. In this study, the feasibility of creating a specialized APP to evaluate different screw-plate configurations for diaphyseal femoral fractures was investigated. The ultimate goal is to extend this technique to computer-assisted preoperative planning for orthopedic surgery. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Surgical repair of skull fractures in four horses using cuttable bone plates.

    Science.gov (United States)

    Dowling, B A; Dart, A J; Trope, G

    2001-05-01

    Three horses with severely comminuted, open facial bone fractures and one horse with a comminuted, open orbital rim fracture were referred for treatment. Severe facial bone asymmetry and epistaxis were apparent in all cases and subcutaneous emphysema was present in two, however physical and neurological examinations were otherwise normal. Radiography and endoscopy were of some use in assessing the degree of damage, although the true extent of the damage was more apparent at surgery. Surgical reduction of the fractures was recommended to maximise cosmetic and functional outcome. After surgical debridement and reduction of the fractures the bone fragments remained unstable and were not amenable to stabilisation with interfragmentary wires alone, so 2 mm cuttable bone plates were used to maintain fracture alignment. Screw migration occurred in three horses and in one of these horses the plate had to be removed. Other complications were minor and in all horses the fractures healed with good cosmetic and functional outcome. The use of cuttable bone plates should be considered as a reasonable alternative to inter-fragmentary wiring for unstable, comminuted fractures of the facial bones, even where fractures are open.

  20. Distal radius plate of CFR-PEEK has minimal effect compared to titanium plates on bone parameters in high-resolution peripheral quantitative computed tomography: a pilot study.

    Science.gov (United States)

    de Jong, Joost J A; Lataster, Arno; van Rietbergen, Bert; Arts, Jacobus J; Geusens, Piet P; van den Bergh, Joop P W; Willems, Paul C

    2017-02-27

    Carbon-fiber-reinforced poly-ether-ether-ketone (CFR-PEEK) has superior radiolucency compared to other orthopedic implant materials, e.g. titanium or stainless steel, thus allowing metal-artifact-free postoperative monitoring by computed tomography (CT). Recently, high-resolution peripheral quantitative CT (HRpQCT) proved to be a promising technique to monitor the recovery of volumetric bone mineral density (vBMD), micro-architecture and biomechanical parameters in stable conservatively treated distal radius fractures. When using HRpQCT to monitor unstable distal radius fractures that require volar distal radius plating for fixation, radiolucent CFR-PEEK plates may be a better alternative to currently used titanium plates to allow for reliable assessment. In this pilot study, we assessed the effect of a volar distal radius plate made from CFR-PEEK on bone parameters obtained from HRpQCT in comparison to two titanium plates. Plates were instrumented in separate cadaveric human fore-arms (n = 3). After instrumentation and after removal of the plates duplicate HRpQCT scans were made of the region covered by the plate. HRpQCT images were visually checked for artifacts. vBMD, micro-architectural and biomechanical parameters were calculated, and compared between the uninstrumented and instrumented radii. No visible image artifacts were observed in the CFR-PEEK plate instrumented radius, and errors in bone parameters ranged from -3.2 to 2.6%. In the radii instrumented with the titanium plates, severe image artifacts were observed and errors in bone parameters ranged between -30.2 and 67.0%. We recommend using CFR-PEEK plates in longitudinal in vivo studies that monitor the healing process of unstable distal radius fractures treated operatively by plating or bone graft ingrowth.

  1. Treatment of midshaft clavicular nonunion with plate fixation and autologous bone grafting

    DEFF Research Database (Denmark)

    Olsen, Bo Sanderhoff; Vaesel, M T; Søjbjerg, Jens Ole

    1995-01-01

    , and one had a failure. Thirteen of 16 patients were satisfied with the cosmetic outcome, assessing their cosmetic result as either good or excellent. Rigid plate fixation and restoration of clavicular length with autologous cancellous bone graft is recommended for the treatment of symptomatic clavicular...

  2. Conventional bone plate fixation of distal radius and ulna fractures in toy breed dogs.

    Science.gov (United States)

    Ramírez, J M; Macías, C

    2016-03-01

    To describe the outcome of bone plate fixation of distal radius and ulna fractures in toy breed dogs treated with conventional bone plates. Records of 15 toy breed dogs with distal radius and ulna fractures were retrospectively reviewed for signalment, method of fixation, complications and clinical and radiographic assessments. A telephone-based owner questionnaire was conducted to determine long-term function and client satisfaction. Age ranged from 4 months to 6 years. Body weight ranged from 1 to 4 kg. Dynamic compression plates were used in 13 dogs and veterinary cuttable plates were used in 2 dogs as the means of fixation. Full radiographic and clinical follow-up data were available for 10 dogs and follow-up was performed between 6 and 8 weeks postoperatively. At that time, all fractures had healed and return to function was considered excellent in all 10 dogs. Five dogs did not return for hospital evaluation because they were judged by their owners to be free of lameness. In two cases, owners could not be contacted by telephone, but the referring veterinarians reported the dogs to be asymptomatic. No major complications occurred. Conventional bone plates are suitable choices for stabilisation of distal radius and ulna fractures in toy breed dogs and are not necessarily correlated with high rates of complication. © 2016 Australian Veterinary Association.

  3. Virtual haptic system for intuitive planning of bone fixation plate placement

    Directory of Open Access Journals (Sweden)

    Kup-Sze Choi

    2017-01-01

    Full Text Available Placement of pre-contoured fixation plate is a common treatment for bone fracture. Fitting of fixation plates on fractured bone can be preoperatively planned and evaluated in 3D virtual environment using virtual reality technology. However, conventional systems usually employ 2D mouse and virtual trackball as the user interface, which makes the process inconvenient and inefficient. In the paper, a preoperative planning system equipped with 3D haptic user interface is proposed to allow users to manipulate the virtual fixation plate intuitively to determine the optimal position for placement on distal medial tibia. The system provides interactive feedback forces and visual guidance based on the geometric requirements. Creation of 3D models from medical imaging data, collision detection, dynamics simulation and haptic rendering are discussed. The system was evaluated by 22 subjects. Results show that the time to achieve optimal placement using the proposed system was shorter than that by using 2D mouse and virtual trackball, and the satisfaction rating was also higher. The system shows potential to facilitate the process of fitting fixation plates on fractured bones as well as interactive fixation plate design.

  4. Minimally Invasive Plate Osteosynthesis In The Treatment Of Isolated Ulnar Bone Fractures

    Directory of Open Access Journals (Sweden)

    Suman K Shrestha

    2012-11-01

    Full Text Available BACKGROUND: Minimally invasive internal fixation is also called “biological internal fixation”. This concept is used widely in the treatment of various fractures but to date, there have been no report about such application in the repair of isolated ulnar bone fractures. METHODS: Eleven patients with fracture of isolated ulnar bone (four AO type 22A11 and seven AO type 22A12, mean age 43.16 (range, 24- 59y, were treated using closed reduction and locking compression plate with minimally invasive plate osteosynthesis (MIPO with the aim of minimising soft tissue damage. RESULTS: Fractures healed at an average of 7.8 weeks with good to excellent clinical outcomes. There were no complications such as nonunion, implant failure or neurovascular injuries. CONCLUSIONS: MIPO seems to be advantageous for soft tissue and bone biology. Good union was seen and fracture complications were also prevented by early mobilisation.

  5. A novel combined method of osteosynthesis in treatment of tibial fractures: a comparative study on sheep with application of rod-through-plate fixator and bone plating.

    Science.gov (United States)

    Tralman, G; Andrianov, V; Arend, A; Männik, P; Kibur, R T; Nõupuu, K; Uksov, D; Aunapuu, M

    2013-04-01

    The study compares the efficiency of a new bone fixator combining periostal and intramedullary osteosynthesis to bone plating in treatment of tibial fractures in sheep. Experimental osteotomies were performed in the middle third of the left tibia. Animals were divided into two groups: in one group (four animals) combined osteosynthesis (rod-through-plate fixator, RTP fixator) was applied, and in the other group (three animals) bone plating was used. The experiments lasted for 10 weeks during which fracture union was followed by radiography, and the healing process was studied by blood serum markers reflecting bone turnover and by histological and immunohistochemical investigations. In the RTP fixator group, animals started to load body weight on the operated limbs the next day after the surgery, while in the bone plating group, this happened only on the seventh day. In the RTP fixator group, consolidation of fractures was also faster, as demonstrated by radiographical, histological, and immunohistochemical investigations and in part by blood serum markers for bone formation. It can be concluded that application of RTP fixation is more efficient than plate fixation in the treatment of experimental osteotomies of long bones in sheep. © 2012 Blackwell Verlag GmbH.

  6. Structure model index does not measure rods and plates in trabecular bone

    Directory of Open Access Journals (Sweden)

    Phil L Salmon

    2015-10-01

    Full Text Available Structure model index (SMI is widely used to measure rods and plates in trabecular bone. It exploits the change in surface curvature that occurs as a structure varies from spherical (SMI = 4, to cylindrical (SMI = 3 to planar (SMI = 0. The most important assumption underlying SMI is that the entire bone surface is convex and that the curvature differential is positive at all points on the surface. The intricate connections within the trabecular continuum suggest that a high proportion of the surface could be concave, violating the assumption of convexity and producing regions of negative differential. We implemented SMI in the BoneJ plugin and included the ability to measure the amounts of surface that increased or decreased in area after surface mesh dilation, and the ability to visualize concave and convex regions. We measured SMI and its positive (SMI+ and negative (SMI- components, bone volume fraction (BV/TV, the fraction of the surface that is concave (CF, and mean ellipsoid factor (EF in trabecular bone using 38 X-ray microtomography (XMT images from a rat ovariectomy model of sex steroid rescue of bone loss, and 169 XMT images from a broad selection of 87 species' femora (mammals, birds, and a crocodile. We simulated bone resorption by eroding an image of elephant trabeculae and recording SMI and BV/TV at each erosion step. Up to 70%, and rarely less than 20%, of the trabecular surface is concave (CF 0.155 – 0.700. SMI is unavoidably influenced by aberrations from SMI-, which is strongly correlated with BV/TV and CF. The plate-to-rod transition in bone loss is an erroneous observation resulting from SMI's close and artefactual relationship with BV/TV. SMI cannot discern between the distinctive trabecular geometries typical of mammalian and avian bone, whereas EF clearly detects birds' more plate-like trabeculae. EF is free from confounding relationships with BV/TV and CF. SMI results reported in the literature should be treated with

  7. Ex vivo flexural mechanical properties of bovine bone plates after tibiae osteosynthesis in rabbits

    Directory of Open Access Journals (Sweden)

    Manuela Aleluia Drago

    2015-10-01

    Full Text Available ABSTRACT. Drago M.A., Drago M., Cerqueira H.D.B., Tiburcio M.F., Souza G.B., Barbosa D.H., Santos C.M.L., Silva R.V. & Freitas P.M.C. [Ex vivo flexural mechanical properties of bovine bone plates after tibiae osteosynthesis in rabbits.] Avaliação ex vivo das propriedades mecânicas em flexão de placas ósseas bovina na osteossíntese de tíbias de coelhos. Revista Brasileira de Medicina Veterinária, 37(3:245-249, 2015. Programa de Pós-Graduação em Ciências Veterinárias, Universidade Federal do Espírito Santo (UFES, Alto Universitário, s/nº, Bairro Guararema, Alegre, ES 29500-000, Brasil. E-mail: manudrago@hotmail.com The use of materials produced from bovine bone has been proposed in the manufacture of implants such as pins, plates and screws, due to their osteoinductive and osteoconductive properties or functions of bone graft. However, structural and mechanical aspects must be evaluated prior to the use, in vivo of bone implants. The aim of this study was to evaluate mechanical strength, through a mechanical bending test, of plates produced from bovine cortical bone, used to repair fractures of the tíbia of rabbits ex vivo. Twenty six plates were manufactured from bovine cortical bone and stored in saturated salt solution. Three study groups were used: group GP (n = 10, made up of the bone plates; GTP group (n = 16, rabbit tibia osteotomized and stabilized with bone plates and four screws and Group GT (n = 10, intact tibia. A three-point bending biomechanical test was used to determine the maximum tension, maximum deflection, and stiffness. The results were submitted to Kruskal-Wallis test (p <0.05 and the Dunn test. Comparing GT with the GTP, an 80% reduction was observed in maximum tension. Also noted was a reduction of 87% in maximum tension when comparing GP with GTP. Therefore, the bovine bone plate had a higher maximum tension then the intact rabbit tibia. There was a reduction of 52% in the rigidity of GTP to GT. No

  8. Bortezomib is cytotoxic to the human growth plate and permanently impairs bone growth in young mice.

    Directory of Open Access Journals (Sweden)

    Emma Eriksson

    Full Text Available Bortezomib, a novel proteasome inhibitor approved for the treatment of cancer in adults, has recently been introduced in pediatric clinical trials. Any tissue-specific side effects on bone development have to our knowledge not yet been explored. To address this, we experimentally studied the effects of bortezomib in vivo in young mice and in vitro in organ cultures of rat metatarsal bones and human growth plate cartilage, as well as in a rat chondrocytic cell line. We found that bortezomib while efficiently blocking the ubiquitin/proteasome system (UPS caused significant growth impairment in mice, by increasing resting/stem-like chondrocyte apoptosis. Our data support a local action of bortezomib, directly targeting growth plate chondrocytes leading to decreased bone growth since no suppression of serum levels of insulin-like growth factor-I (IGF-I was observed. A local effect of bortezomib was confirmed in cultured rat metatarsal bones where bortezomib efficiently caused growth retardation in a dose dependent and irreversible manner, an effect linked to increased chondrocyte apoptosis, mainly of resting/stem-like chondrocytes. The cytotoxicity of bortezomib was also evaluated in a unique model of cultured human growth plate cartilage, which was found to be highly sensitive to bortezomib. Mechanistic studies of apoptotic pathways indicated that bortezomib induced activation of p53 and Bax, as well as cleavage of caspases and poly-ADP-ribose polymerase (PARP in exposed chondrocytes. Our observations, confirmed in vivo and in vitro, suggest that bone growth could potentially be suppressed in children treated with bortezomib. We therefore propose that longitudinal bone growth should be closely monitored in ongoing clinical pediatric trials of this promising anti-cancer drug.

  9. A free plate model can predict guided modes propagating in tubular bone-mimicking phantoms.

    Science.gov (United States)

    Minonzio, Jean-Gabriel; Foiret, Josquin; Moilanen, Petro; Pirhonen, Jalmari; Zhao, Zuomin; Talmant, Maryline; Timonen, Jussi; Laugier, Pascal

    2015-01-01

    The goal of this work was to show that a non-absorbing free plate model can predict with a reasonable accuracy guided modes measured in bone-mimicking phantoms that have circular cross-section. Experiments were carried out on uncoated and coated phantoms using a clinical axial transmission setup. Adjustment of the plate model to the experimental data yielded estimates for the waveguide characteristics (thickness, bulk wave velocities). Fair agreement was achieved over a frequency range of 0.4 to 1.6 MHz. A lower accuracy observed for the thinnest bone-mimicking phantoms was caused by limitations in the wave number measurements rather than by the model itself.

  10. 3D printed personalized titanium plates improve clinical outcome in microwave ablation of bone tumors around the knee.

    Science.gov (United States)

    Ma, Limin; Zhou, Ye; Zhu, Ye; Lin, Zefeng; Chen, Lingling; Zhang, Yu; Xia, Hong; Mao, Chuanbin

    2017-08-08

    Microwave ablation has been widely accepted in treating bone tumor. However, its procedure is time-consuming and usually results in postoperative fractures. To solve this problem, we designed and fabricated titanium plates customized to the patients' bone structures. The personalized titanium plates were then used for fixation after the removal of tumorous tissue. Specifically, 3D models of tumor-bearing bone segments were constructed by using computed tomography (CT) and magnetic resonance imaging (MRI). The 3D models were used to design the personalized titanium plates. The plate model was transferred into a numerical control machine for manufacturing the personalized titanium plates by 3D printing. The plates were then surgically implanted for reconstruction assistance following microwave-induced hyperthermia to remove the bone tumor. Implementation parameters and knee functions were then evaluated. No postoperative fractures, implant failures or loosening problems occurred; mean Musculoskeletal Tumor Society score was 27.17 from the latest follow-up. Mean maximum flexion of affected knees was 114.08°. The results of knee gait analysis were comparable with normal population data. Our work suggests that personalized titanium plates can significantly improve the clinical outcomes in the surgical removal of bone tumor. This study represents the first-time effort in using personalized titanium plates for such surgery.

  11. Propagation of ultrasonic guided waves in an acrylic plate as a cortical-bone-mimicking phantom

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kang Il [Kangwon National University, Chuncheon (Korea, Republic of); Choi, Bok Kyoung [Maritime Security Research Center, KIOST, Ansan (Korea, Republic of)

    2014-12-15

    The present study aims to investigate the propagation of ultrasonic guided waves in an acrylic plate as a cortical-bone-mimicking phantom. The velocities of the guided waves in a 5-mm-thick acrylic plate were measured by using the axial transmission technique. A pure A0 Lamb mode could be successfully launched in the 5-mm-thick acrylic plate through a time reversal process of Lamb waves, consistent with the fact that the time reversal process can automatically compensate for the dispersive nature of Lamb waves. The experimental velocities of the slow guided wave (SGW) and the time-reversed Lamb wave were found to be in reasonable agreement with the theoretical group velocity of the A0 Lamb mode, suggesting that both the SGW and the time-reversed Lamb wave excited in the 5-mm-thick acrylic plate correspond to the A0 Lamb mode. These results suggest that the time reversal process of Lamb waves can be usefully applied to noninvasive characterization of long cortical bones.

  12. Velocity dispersion of guided waves propagating in a free gradient elastic plate: application to cortical bone.

    Science.gov (United States)

    Vavva, Maria G; Protopappas, Vasilios C; Gergidis, Leonidas N; Charalambopoulos, Antonios; Fotiadis, Dimitrios I; Polyzos, Demosthenes

    2009-05-01

    The classical linear theory of elasticity has been largely used for the ultrasonic characterization of bone. However, linear elasticity cannot adequately describe the mechanical behavior of materials with microstructure in which the stress state has to be defined in a non-local manner. In this study, the simplest form of gradient theory (Mindlin Form-II) is used to theoretically determine the velocity dispersion curves of guided modes propagating in isotropic bone-mimicking plates. Two additional terms are included in the constitutive equations representing the characteristic length in bone: (a) the gradient coefficient g, introduced in the strain energy, and (b) the micro-inertia term h, in the kinetic energy. The plate was assumed free of stresses and of double stresses. Two cases were studied for the characteristic length: h=10(-4) m and h=10(-5) m. For each case, three subcases for g were assumed, namely, g>h, gguided waves were numerically obtained and compared with the Lamb modes. The results indicate that when g was not equal to h (i.e., g not equal h), microstructure affects mode dispersion by inducing both material and geometrical dispersion. In conclusion, gradient elasticity can provide supplementary information to better understand guided waves in bones.

  13. Biomechanical analysis and quantitative analysis of bone scintigraphy on thrust plate hip prosthesis.

    Science.gov (United States)

    Goto, Toshihiko; Yasunaga, Yuji; Takahashi, Kazuhiro; Ochi, Mitsuo

    2004-07-01

    To study the load distribution of the thrust plate hip prosthesis (TPP, Sulzer Medica, Baar, Switzerland) on femoral bone, a TPP insertion group and intramedullary cemented stem insertion group were prepared with the use of embalmed femoral anatomic specimens, and strain on the femoral bone induced by loading was measured. Bone scintigraphy was performed in 26 joints which underwent total hip arthroplasty with the use of TPP, to enable quantitative evaluation of postoperative remodeling of the bone. In the TPP insertion group, the strain was almost equivalent to that in the untreated femoral control group. On the other hand, compared with the control group and TPP insertion group, strain in the proximal portion of the femoral bone (medial side of the femoral neck) was significantly smaller in the cemented stem group (control group versus cemented stem insertion group, p=0.0062; cemented stem insertion group versus TPP 130 degrees insertion group, p=0.0005; cemented stem insertion group versus TPP 140 degrees insertion group, p=0.0031). Bone scintigrams revealed decreased uptake at 12 weeks after operation compared with 6 weeks after operation, indicating that TPP allows earlier implant stabilization than the conventional stem. Compared with the conventional stem, TPP is a prosthesis that can perform physiological load transmission.

  14. Ultrasonic wave propagation in viscoelastic cortical bone plate coupled with fluids: a spectral finite element study.

    Science.gov (United States)

    Nguyen, Vu-Hieu; Naili, Salah

    2013-01-01

    This work deals with the ultrasonic wave propagation in the cortical layer of long bones which is known as being a functionally graded anisotropic material coupled with fluids. The viscous effects are taken into account. The geometrical configuration mimics the one of axial transmission technique used for evaluating the bone quality. We present a numerical procedure adapted for this purpose which is based on the spectral finite element method (FEM). By using a combined Laplace-Fourier transform, the vibroacoustic problem may be transformed into the frequency-wavenumber domain in which, as radiation conditions may be exactly introduced in the infinite fluid halfspaces, only the heterogeneous solid layer needs to be analysed using FEM. Several numerical tests are presented showing very good performance of the proposed approach. We present some results to study the influence of the frequency on the first arriving signal velocity in (visco)elastic bone plate.

  15. Distraction osteogenesis using combined locking plate and Ilizarov fixator in the treatment of bone defect: A report of 2 cases

    Directory of Open Access Journals (Sweden)

    John Mukhopadhaya

    2017-01-01

    Full Text Available Distraction osteogenesis and bone transport has been used to reconstruct bone loss defect by allowing new bone to form in the gap. Plate-guided bone transport has been successfully described in literature to treat bone loss defect in the femur, tibia, and mandible. This study reports two cases of fracture of femur with segmental bone loss treated with locking plate fixation and bone transport with Ilizarov ring fixator. At the time of docking, when the transport segment is compressed with bone fragment, the bone fragment is fixed with additional locking or nonlocking screws through the plate. The bone defect size was 7 cm in case 1 and 8 cm in case 2 and the external fixation indexes were 12.7 days/cm and 14 days/cm. No shortening was present in either of our cases. The average radiographic consolidation index was 37 days/cm. Both cases achieved infection-free bone segment regeneration and satisfactorily functional outcome. This technique reduces the duration of external fixation during the consolidation phase, allows correction of length and alignment and provides earlier rehabilitation.

  16. Use of a bone plate for treatment of middle phalangeal fractures in horses: seven cases (1979-1984)

    International Nuclear Information System (INIS)

    Doran, R.E.; White, N.A. II; Allen, D.

    1987-01-01

    Four adult horses and 3 foals with middle phalangeal fractures were treated by arthrodesis of the proximal interphalangeal joint, using a bone plate. Six of the 7 horses survived greater than 2 years; 2 of the 6 horses had intermittent lameness after hard work, and 4 horses didn't have evidence of lameness. The use of a bone plate for arthrodesis of the proximal interphalangeal joint was a successful treatment alternative for middle phalangeal fractures in horses

  17. A study of 2 bone plating methods for fractures of the mandibular symphysis/body.

    Science.gov (United States)

    Ellis, Edward

    2011-07-01

    The purpose of this investigation was to evaluate outcomes for 2 bone plating techniques used in the treatment of mandibular symphysis/body fractures. All patients with adequate records treated for fractures of the mandibular body or symphysis by 2 miniplates or 1 stronger plate over an 11-year period were included. Demographic and outcome variables were collected and statistically analyzed to determine if the 2 treatments produced different outcomes. Six hundred eighty-two patients had sufficient follow-up for inclusion in this study. There were no significant differences in demographic data for the 2 groups. There were no statistically significant differences in occlusal or osseous healing outcomes. However, there were significant differences in treatment outcomes for several variables, including wound dehiscence, plate exposure, the need for plate removal, and tooth root damage between the groups. The use of 2 miniplates was associated with more postoperative complications than the use of 1 stronger plate, but both techniques produced sufficient stability for healing. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Bone plate composed of a ternary nano-hydroxyapatite/polyamide 66/glass fiber composite: biomechanical properties and biocompatibility.

    Science.gov (United States)

    Qiao, Bo; Li, Jidong; Zhu, Qingmao; Guo, Shuquan; Qi, Xiaotong; Li, Weichao; Wu, Jun; Liu, Yang; Jiang, Dianming

    2014-01-01

    An ideal bone plate for internal fixation of bone fractures should have good biomechanical properties and biocompatibility. In this study, we prepared a new nondegradable bone plate composed of a ternary nano-hydroxyapatite/polyamide 66/glass fiber (n-HA/PA66/GF) composite. A breakage area on the n-HA/PA66/GF plate surface was characterized by scanning electron microscopy. Its mechanical properties were investigated using bone-plate constructs and biocompatibility was evaluated in vitro using bone marrow-derived mesenchymal stem cells. The results confirmed that adhesion between the n-HA/PA66 matrix and the glass fibers was strong, with only a few fibers pulled out at the site of breakage. Fractures fixed by the n-HA/PA66/GF plate showed lower stiffness and had satisfactory strength compared with rigid fixation using a titanium plate. Moreover, the results with regard to mesenchymal stem cell morphology, MTT assay, Alizarin Red S staining, enzyme-linked immunosorbent assay, and reverse transcription polymerase chain reaction for alkaline phosphatase and osteocalcin showed that the n-HA/PA66/GF composite was suitable for attachment and proliferation of mesenchymal stem cells, and did not have a negative influence on matrix mineralization or osteogenic differentiation of mesenchymal stem cells. These observations indicate that the n-HA/PA66/GF plate has good biomechanical properties and biocompatibility, and may be considered a new option for internal fixation in orthopedic surgery.

  19. Resorbable plate osteosynthesis of sagittal split osteotomies with major bone movement.

    Science.gov (United States)

    Landes, Constantin A; Kriener, Susanne

    2003-05-01

    This study evaluates resorbable miniplate osteosyntheses in sagittal split osteotomies with major bone repositioning. Two resorbable 2.0-mm miniplate systems, MacroSorb (Macropore, San Diego, Calif.) and PolyMax (Synthes, Oberdorf, Switzerland), were compared consecutively. Amorphous 70:30 poly-L/DL-lactide copolymer plates sustain continuous hydrolysis through water penetration into the implant body during the first 6 months in situ. This breaks copolymer chains into smaller particles, which later become degraded through phagocytotic cells. Eighteen patients, 10 women and eight men, 16 to 57 years old (average, 27 years) were examined. They had severe dysgnathia caused by congenital craniofacial malformations, systemic disorders, trauma, amelogenesis imperfecta, oligodontia, and other conditions, and they needed five 8- to 10-mm and 13 major 10- to 12-mm repositions. Twelve sagittal split osteotomies were fixed with 12 MacroSorb plates in six patients, and 24 osteotomies were filled with 32 PolyMax plates in 12 patients. Ten mandibular plate, screw, hard-tissue, and soft-tissue specimens were taken at 3, 6, 9, or 12 months postoperatively in secondary operations (e.g., dental implant placement).Follow-up ranged from 4 to 19 months; all osteosyntheses reossified. Four patients showed proximal fragments rotated up to 5 mm sagittally anteriorly and nonaligned burr holes on the postoperative radiogram, suggesting plate fractures or screw pullout. When plate fracture was noted, guided occlusion was maintained 4 weeks after surgery. Occlusal, radiologic, and skeletal results remained stable. After starting fixation with two plates on each side, no more plate fractures were seen. In three other patients, minor skeletal relapses up to 3 mm horizontally resulted. Local histologic inspection of specimens showed thorough osseous union. Screw remnants embedded in bone made screw pullout unlikely; rather, screw-head or plate fractures were found as multiple degraded particles

  20. Spatial regulation of bone morphogenetic proteins (BMPs) in postnatal articular and growth plate cartilage

    Science.gov (United States)

    Garrison, Presley; Yue, Shanna; Hanson, Jeffrey; Baron, Jeffrey; Lui, Julian C.

    2017-01-01

    Articular and growth plate cartilage both arise from condensations of mesenchymal cells, but ultimately develop important histological and functional differences. Each is composed of three layers—the superficial, mid and deep zones of articular cartilage and the resting, proliferative and hypertrophic zones of growth plate cartilage. The bone morphogenetic protein (BMP) system plays an important role in cartilage development. A gradient in expression of BMP-related genes has been observed across growth plate cartilage, likely playing a role in zonal differentiation. To investigate the presence of a similar expression gradient in articular cartilage, we used laser capture microdissection (LCM) to separate murine growth plate and articular cartilage from the proximal tibia into their six constituent zones, and used a solution hybridization assay with color-coded probes (nCounter) to quantify mRNAs for 30 different BMP-related genes in each zone. In situ hybridization and immunohistochemistry were then used to confirm spatial expression patterns. Expression gradients for Bmp2 and 6 were observed across growth plate cartilage with highest expression in hypertrophic zone. However, intracellular BMP signaling, assessed by phospho-Smad1/5/8 immunohistochemical staining, appeared to be higher in the proliferative zone and prehypertrophic area than in hypertrophic zone, possibly due to high expression of Smad7, an inhibitory Smad, in the hypertrophic zone. We also found BMP expression gradients across the articular cartilage with BMP agonists primarily expressed in the superficial zone and BMP functional antagonists primarily expressed in the deep zone. Phospho-Smad1/5/8 immunohistochemical staining showed a similar gradient. In combination with previous evidence that BMPs regulate chondrocyte proliferation and differentiation, the current findings suggest that BMP signaling gradients exist across both growth plate and articular cartilage and that these gradients may

  1. Correction of bone angular deformities: experimental analysis of staples versus 8-plate.

    Science.gov (United States)

    Goyeneche, Rodolfo A; Primomo, Claudio E; Lambert, Norberto; Miscione, Horacio

    2009-01-01

    Hemi-epiphysiodesis should always be considered as an effective treatment to correct axial limb deformity in children. The use of the 8-plate as opposed to conventional staples provides firm fixation to both sides of the physis, acting mainly upon the epiphyseal growth site of the implant insertion. The aim of our study is to compare the effectiveness of both devices for performing angular corrections. Seventeen rabbits of 18 months of age were treated with an 8-plate in the distal femur and a staple in the contralateral femur. Eight weeks later, the level of deformity produced by each device was evaluated both radiographically and histologically. Axial deformity: the staples produced an average deviation of 48.1 degrees, and the 8-plate produced an average deviation of 49.1 degrees (P=0.44). Final longitudinal growth of the femurs: we recorded an average of 83.17 degrees for the staples and 85.7 degrees for the 8-plate. Histologic analysis: no significant difference was observed between both femurs of the same specimen; however, a slight difference was recorded when analyzing the results of different animals. Correction was achieved in less time when using conventional staples. The long-term effectiveness of both epiphysiodesis is similar. Longitudinal growth inhibition is lower when using 8-plate. Although both methods are effective in stopping the growth, the 8-plate has better grasp to the bone or epiphyseal cartilage avoiding extrusion in small children. The correction is faster using a staple and that is the reason why we prefer its usage in patients with little remnant growth.

  2. Fracture patterns of the growth plate and surrounding bone in the ovine knee joint at different ages.

    Science.gov (United States)

    Celarek, A; Fischerauer, S F; Weinberg, A M; Tschegg, E K

    2014-01-01

    Fractures of the growth plate region were performed with cadaver specimens obtained from the ovine distal femur and proximal tibia. Specimens of 6 different ages, ranging from 1 week to 4 years, were investigated in order to determine changes in the fracture characteristics. Mechanical properties (crack resistance and notch tensile strength), supported by microscopy of the distal tibia (thickness of growth plate and its zones, trabecular bone volume ratio) were determined. The crack propagated through different regions depending on age, which was observed both in microscopy and mechanical tests. In specimens of younger animals the fracture typically went through trabecular bone, often parallel to the growth plate, and only sometimes through the growth plate cartilage. Specimens of older animals fractured directly through the growth plate cartilage, while trabecular bone was not affected at all. Adult specimens had significantly higher mechanical values than the young ones. The results reveal the underlying mechanical properties that induce different fracture patterns of the epiphyseal growth plate at different stages of growth. The possibility of fractures through trabecular bone parallel to the growth plate in newborns and infants should be considered when clinical radiographs of paediatric fractures are analysed and classified. © 2013 Elsevier Ltd. All rights reserved.

  3. Local plate/rod descriptors of 3D trabecular bone micro-CT images from medial axis topologic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Peyrin, Francoise; Attali, Dominique; Chappard, Christine; Benhamou, Claude Laurent [CREATIS, UMR CNRS 5220, 69621 Villeurbanne (France); Inserm, U 630, 69621 Villeurbanne (France); Insa de Lyon, 69621 Villeurbanne (France); Universite Lyon I, 69621 Villeurbanne (France); Universite de Lyon, 69621 Villeurbanne (France) and ESRF (European Synchrotron Radiation Facility), BP 220, 38043 Grenoble (France); GIPSA Laboratory, UMR CNRS 5216, 38402 Grenoble (France); Inserm, U 658, 45032 Orleans Cedex 1 (France) and B20A, UMR7052 CNRS, Universite Paris 7, 75010 Paris (France); Inserm, U 658, 45032 Orleans Cedex 1 (France)

    2010-08-15

    Purpose: Trabecular bone microarchitecture is made of a complex network of plate and rod structures evolving with age and disease. The purpose of this article is to propose a new 3D local analysis method for the quantitative assessment of parameters related to the geometry of trabecular bone microarchitecture. Methods: The method is based on the topologic classification of the medial axis of the 3D image into branches, rods, and plates. Thanks to the reversibility of the medial axis, the classification is next extended to the whole 3D image. Finally, the percentages of rods and plates as well as their mean thicknesses are calculated. The method was applied both to simulated test images and 3D micro-CT images of human trabecular bone. Results: The classification of simulated phantoms made of plates and rods shows that the maximum error in the quantitative percentages of plate and rods is less than 6% and smaller than with the structure model index (SMI). Micro-CT images of human femoral bone taken in osteoporosis and early or advanced osteoarthritis were analyzed. Despite the large physiological variability, the present method avoids the underestimation of rods observed with other local methods. The relative percentages of rods and plates were not significantly different between osteoarthritis and osteoporotic groups, whereas their absolute percentages were in relation to an increase of rod and plate thicknesses in advanced osteoarthritis with also higher relative and absolute number of nodes. Conclusions: The proposed method is model-independent, robust to surface irregularities, and enables geometrical characterization of not only skeletal structures but entire 3D images. Its application provided more accurate results than the standard SMI on simple simulated phantoms, but the discrepancy observed on the advanced osteoarthritis group raises questions that will require further investigations. The systematic use of such a local method in the characterization of

  4. Biomechanical Comparison of Cadaveric and Commercially Available Synthetic Osteoporotic Bone Analogues in a Locked Plate Fracture Model Under Torsional Loading.

    Science.gov (United States)

    Becker, Edward H; Kim, Hyunchul; Shorofsky, Michael; Hsieh, Adam H; Watson, Jeffrey D; OʼToole, Robert V

    2017-05-01

    Biomechanical studies of osteoporotic bone have used synthetic models rather than cadaveric samples because of decreased variability, increased availability, and overall ease of the use of synthetic models. We compared the torsional mechanical properties of cadaveric osteoporotic bone with those of currently available synthetic osteoporotic bone analogues. We tested 12 osteoporotic cadaveric humeri and 6 specimens each of 6 types of synthetic analogues. A 5-mm fracture gap model and posterior plating technique with 4.5-mm narrow 10-hole locking compression plate were used. Torque was applied to a peak of ±10 N·m for 1000 cycles at 0.3 Hz. Data were continuously collected during cyclical and ramped loading with a servohydraulic materials testing system. Cadaveric bone had a 17% failure rate before completing 1000 cycles. Three osteoporotic bone models had 100% failure (P Osteoporotic bone analogues had torsional mechanical properties different from those of osteoporotic cadaveric specimens. The differences between osteoporotic cadaveric humeri and synthetic osteoporotic bone analogues ranged from profound with complete catastrophic failure after a few cycles to subtler differences in stiffness and strain hardening. These findings suggest that different bone analogue models vary substantially in their torsional mechanical properties and might not be appropriate substitutes for cadaveric bone in biomechanical studies of osteoporotic bone.

  5. Repair of long-bone fractures in cats and small dogs with the Unilock mandible locking plate system.

    Science.gov (United States)

    Voss, K; Kull, M; Hässig, M; Montavon, P

    2009-01-01

    To retrospectively evaluate stabilisation of long-bone fractures in cats and small dogs using the Unilock system. Medical histories and radiographs of consecutive patients with long-bone fractures stabilised with the Unilock system were reviewed. Cases with follow-up radiographs taken at least four weeks postoperatively were included. Signalment of the patient, fracture localisation and type, primary fracture repair or revision surgery, single or double plating, and complications for each patient were noted. Additionally, implant size, number of screws, number of cortices engaged with screws, and number of empty holes across the fracture were evaluated in fractures where a single plate had been applied. Eighteen humeral, 18 radial, 20 femoral, and 10 tibial fractures were treated. The Unilock system was used for primary repair in 44 fractures and for revision surgery in 22 fractures. Two plates were applied in 17 fractures, and a single plate was applied in 49 fractures. Follow-up radiographs were taken four to 109 weeks postoperatively. Complications were seen in 12 animals and 13 fractures (19.7%). Fixation failure occurred in seven fractures (10.6%). Cases with a single plate that suffered fixation failure had thinner screws in relation to bone diameter than cases with double plates, and more screws in a main fragment than those without fixation failure. The Unilock system is a suitable implant for fracture fixation of long bones in cats and small dogs.

  6. Dual plating with bone block arthrodesis of the first metatarsophalangeal joint: A clinical retrospective review.

    Science.gov (United States)

    Bei, Chaoyong; Gross, Christopher E; Adams, Samuel; Parekh, Selene G

    2015-12-01

    First metatarsal phalangeal joint (MTP) arthrodesis is challenging in the setting of bone loss. The purpose of this study was to describe the results of interpositional grafting and arthrodesis of the first MTP joint using two plates in a 90/90 configuration. Eleven patients had an MTP arthrodesis with 90-90 plating with an interpositional allograft. We analyzed the fusion rate, restoration of first ray length, patient satisfaction, and complication rates. The overall union rate was 90.9%, with an average restoration of 11 ± 4.5mm in length to the first ray. The average time to fusion was 10.7 ± 1 weeks. The mean preoperative AOFAS score improved significantly. The complication rate was 18.2% and included one superficial wound infection and one non-union who underwent a successful fusion after revision. Arthrodesis of the first MTP joint with two 90/90 plates and restoration of length using an interpositional graft has excellent patient satisfaction and functional outcomes. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  7. Immediate periodontal bone plate changes induced by rapid maxillary expansion in the early mixed dentition: CT findings

    Directory of Open Access Journals (Sweden)

    Daniela Gamba Garib

    2014-06-01

    Full Text Available OBJECTIVE: This study aimed at evaluating buccal and lingual bone plate changes caused by rapid maxillary expansion (RME in the mixed dentition by means of computed tomography (CT. METHODS: The sample comprised spiral CT exams taken from 22 mixed dentition patients from 6 to 9 years of age (mean age of 8.1 years presenting constricted maxillary arch treated with Haas-type expanders. Patients were submitted to spiral CT scan before expansion and after the screw activation period with a 30-day interval between T1 and T2. Multiplanar reconstruction was used to measure buccal and lingual bone plate thickness and buccal bone crest level of maxillary posterior deciduous and permanent teeth. Changes induced by expansion were evaluated using paired t test (p < 0.05. RESULTS: Thickness of buccal and lingual bone plates of posterior teeth remained unchanged during the expansion period, except for deciduous second molars which showed a slight reduction in bone thickness at the distal region of its buccal aspect. Buccal bone dehiscences were not observed in the supporting teeth after expansion. CONCLUSION: RME performed in mixed dentition did not produce immediate undesirable effects on periodontal bone tissues.

  8. Volumetric topological analysis: a novel method for trabecular bone characterization on the continuum between plates and rods

    Science.gov (United States)

    Saha, Punam K.; Xu, Yan; Liang, Guoyuan; Duan, Hong

    2009-02-01

    Trabecular bone (TB) is a complex quasi-random network of interconnected struts and plates. TB constantly remodels to adapt dynamically to the stresses to which it is subjected (Wolff's Law). In osteoporosis, this dynamic equilibrium between bone formation and resorption is perturbed, leading to bone loss and structural deterioration, both increasing fracture risk. Bone's mechanical competence can only be partly explained by variations in bone mineral density, which led to the notion of bone structural quality. Previously, we developed digital topological analysis or DTA which classifies plates, rods, profiles, edges and junctions in a TB skeletal representation. Although the method has become quite popular, a major limitation is that DTA produces hard classifications only, failing to distinguish between narrow and wide plates. Here, we present a new method called volumetric topological analysis or VTA for quantification of regional topology in complex quasi-random TB networks. At each TB voxel, the method uniquely classifies the topology on the continuum between perfect plates and rods. Therefore, the method is capable of detecting early alterations of trabeculae from plates to rods according to the known etiology of osteoporotic bone loss. Here, novel ideas of geodesic distance transform, geodesic scale and feature propagation have been introduced and combined with DTA and fuzzy distance transform methods conceiving the new VTA technology. The method has been applied to MDCT and μCT images of a cadaveric distal tibia specimen and the results have been quantitatively evaluated. Specifically, intra- and inter-modality reproducibility of the method has been examined and the results are found very promising.

  9. The management of unstable oblique infected mandibular fractures with a 2.3 mm mandibular osteosynthesis reconstruction bone plate.

    Science.gov (United States)

    Ghanem, Walid A; Elhayes, Khaled A; Saad, Khalid

    2011-12-01

    This study is aimed to evaluate the efficacy of 2.3mm reconstruction bone plates in the treatment of unstable infected mandibular fractures. The study included 32 patients with unstable oblique infected mandibular fractures (23 males and 9 females), with a mean age of 33 years. The patients were divided into two groups. Group 1 were treated with an osteosynthesis plate (with at least 3 screws on each side of fracture sites) applied to the mandibular fracture site, while in group 2 the bone plate was applied (2 screws on each side of fracture sites) with maxillomandibular fixation (MMF). Clinical and radiographic examinations were carefully assessed preoperatively and postoperatively at follow-up intervals of 1, 2, 6, 12 months. Postoperative complications in terms of dysocclusion, wound dehiscence and neurosensory disturbances were examined. Postoperative clinical and radiographic results showed that group 1 had quicker bone generation and more precise anatomical alignment of fracture sites than with those in group 2. All patients showed no evidence of infection, plate fracture or exposure, malunion, osteomyelitis, neurosensory disturbances, or dental injury. The 2.3mm reconstruction bone plates provide excellent stability and healing of the unstable infected mandibular fractures provided that the fracture site is fixed by at least 3 screws on each side of the fracture sites. Copyright © 2010 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Autologous Bone Grafting and Revision Plating in a Case of Persistent High Tibial Osteotomy Non-Union.

    Science.gov (United States)

    Ming, Tan Shi; Koon, Wong Merng

    2016-01-01

    Uni-compartmental knee arthritis may be treated with several surgical options including uni-compartmental knee arthroplasty, total knee arthroplasty and high tibial osteotomy. Non-union is a well-established and common complication that may arise from the latter option and few reports have shown successful treatment of persistent non-union of high tibial osteotomy. We present a case of persistent non-union after high tibial osteotomy treated with autologous iliac crest bone grafting and revision plating. At 1 year post-operative interval, successful union was achieved after revision internal fixation. In addition, a good functional outcome was achieved. In this patient with persistent non-union following high tibial osteotomy, the aim of revision was to restore alignment and effect bone healing while preserving adequate tibial bone stock. Revision plating with autologous bone grafting is a good surgical strategy in the treatment ofpersistent non-union with hardware failure.

  11. Repair of long-bone fractures in cats and small dogs with the Unilock mandible locking plate system

    OpenAIRE

    Voss, K; Kull, M A; Haessig, M; Montavon, P M

    2009-01-01

    Objectives: To retrospectively evaluate stabilisation of long-bone fractures in cats and small dogs using the Unilock system. Methods: Medical histories and radiographs of consecutive patients with long-bone fractures stabilised with the Unilock system were reviewed. Cases with follow-up radiographs taken at least four weeks postoperatively were included. Signalment of the patient, fracture localisation and type, primary fracture repair or revision surgery, single or double plating, and compl...

  12. Multipurpose contrast enhancement on epiphyseal plates and ossification centers for bone age assessment.

    Science.gov (United States)

    Chai, Hum Yan; Swee, Tan Tian; Seng, Gan Hong; Wee, Lai Khin

    2013-04-08

    The high variations of background luminance, low contrast and excessively enhanced contrast of hand bone radiograph often impede the bone age assessment rating system in evaluating the degree of epiphyseal plates and ossification centers development. The Global Histogram equalization (GHE) has been the most frequently adopted image contrast enhancement technique but the performance is not satisfying. A brightness and detail preserving histogram equalization method with good contrast enhancement effect has been a goal of much recent research in histogram equalization. Nevertheless, producing a well-balanced histogram equalized radiograph in terms of its brightness preservation, detail preservation and contrast enhancement is deemed to be a daunting task. In this paper, we propose a novel framework of histogram equalization with the aim of taking several desirable properties into account, namely the Multipurpose Beta Optimized Bi-Histogram Equalization (MBOBHE). This method performs the histogram optimization separately in both sub-histograms after the segmentation of histogram using an optimized separating point determined based on the regularization function constituted by three components. The result is then assessed by the qualitative and quantitative analysis to evaluate the essential aspects of histogram equalized image using a total of 160 hand radiographs that are implemented in testing and analyses which are acquired from hand bone online database. From the qualitative analysis, we found that basic bi-histogram equalizations are not capable of displaying the small features in image due to incorrect selection of separating point by focusing on only certain metric without considering the contrast enhancement and detail preservation. From the quantitative analysis, we found that MBOBHE correlates well with human visual perception, and this improvement shortens the evaluation time taken by inspector in assessing the bone age. The proposed MBOBHE outperforms

  13. PLATE

    DEFF Research Database (Denmark)

    Kling, Joyce; Hjulmand, Lise-Lotte

    2008-01-01

    ’s level of English is sufficient for the increasing number of courses offered in English each semester. This paper addresses these concerns and describes a pilot project initiated in 2003 at CBS to gauge the overall English language proficiency of those teaching content courses in English. Through...... the Project in Language Assessment for Teaching in English (PLATE) language professionals from CBS’s Language Center observe teachers and provide feedback using evaluation criteria from the Common European Framework for Reference (CEFR) supplemented by some additional criteria which take the LSP nature...... of academic teaching and lecturing into account....

  14. Bridging Plate Development for Treatment of Segmental Bone Defects of the Canine Mandible: Mechanical Tests and Finite Element Method.

    Science.gov (United States)

    de Freitas, Elisângela Perez; Rahal, Sheila Canevese; Shimano, Antonio Carlos; da Silva, Jorge Vicente Lopes; Noritomi, Pedro Yoshito; El-Warrak, Alexander Oliveira; Melchert, Alessandra

    2016-03-01

    With regard to the canine mandible, a mistaken concept of application is to assume that systemic plate-bone resistance is provided by the implant so that biomechanical position could be ignored. Because the alveolar border of the mandible is a tensile zone, the plate would ideally be positioned near this area while avoiding important structures. The aim of this study was to develop 2 bridging plates for the treatment of a segmental bone defect of the canine mandible using monocortical screws to avoid damage to the tooth roots and remaining neurovascular structures. Computed tomography images of the heads of 4 dogs (rottweiler, Doberman, boxer, and miniature poodle breeds) were used as models to develop the project. The images were reconstructed in 3-dimensional (3D) format. For each dog breed, 6 mandible prototypes were produced, each with a segmental bone defect in the right mandible. The mandibular reconstruction was performed with pure titanium bridging plate and locking screws. One plate model was developed for medium- and large-breed dogs and another for small-breed dogs. Mechanical testing showed the platemandible system resists the bite forces in all dog breeds. All safety factors were greater than I in the platemandible system for medium- and large-breed dogs and greater than 10 in the plate-mandible system for small-breed dogs. Thus, bridging plates designed with differentiated geometry and monocortical locking screws showed mechanical resistance to support simulated induced bone model defects and were able to support at least 5 times the value of bite force for each evaluated dog.

  15. Impact of attenuation on guided mode wavenumber measurement in axial transmission on bone mimicking plates.

    Science.gov (United States)

    Minonzio, Jean-Gabriel; Foiret, Josquin; Talmant, Maryline; Laugier, Pascal

    2011-12-01

    Robust signal processing methods adapted to clinical measurements of guided modes are required to assess bone properties such as cortical thickness and porosity. Recently, an approach based on the singular value decomposition (SVD) of multidimensional signals recorded with an axial transmission array of emitters and receivers has been proposed for materials with negligible absorption, see Minonzio et al. [J. Acoust. Soc. Am. 127, 2913-2919 (2010)]. In presence of absorption, the ability to extract guided mode degrades. The objective of the present study is to extend the method to the case of absorbing media, considering attenuated plane waves (complex wavenumber). The guided mode wavenumber extraction is enhanced and the order of magnitude of the attenuation of the guided mode is estimated. Experiments have been carried out on 2 mm thick plates in the 0.2-2 MHz bandwidth. Two materials are inspected: polymethylacrylate (PMMA) (isotropic with absorption) and artificial composite bones (Sawbones, Pacific Research Laboratory Inc, Vashon, WA) which is a transverse isotropic absorbing medium. Bulk wave velocities and bulk attenuation have been evaluated from transmission measurements. These values were used to compute theoretical Lamb mode wavenumbers which are consistent with the experimental ones obtained with the SVD-based approach. © 2011 Acoustical Society of America

  16. Surgical management of diaphyseal humeral nonunion after intramedullary nailing: Wave-plate fixation and autologous bone grafting without nail removal

    NARCIS (Netherlands)

    Gerber, Ariane; Marti, René; Jupiter, Jesse

    2003-01-01

    Six patients with a nonunion of the humeral diaphysis after intramedullary nailing were treated with a wave plate and autologous bone graft but without removal of the intramedullary implant. The mean duration of the nonunion was 19 months (range, 6-36 months). At a mean follow-up of 12 months

  17. Mineral density and penetration strength of the subchondral bone plate of the talar dome: high correlation and specific distribution patterns.

    Science.gov (United States)

    Leumann, André; Valderrabano, Victor; Hoechel, Sebastian; Göpfert, Beat; Müller-Gerbl, Magdalena

    2015-01-01

    The subchondral bone plate plays an important role in stabilizing the osteochondral joint unit and in the pathomechanism of osteochondral lesions and osteoarthritis. The objective of the present study was to measure the mineral density distribution and subchondral bone plate penetration strength of the talar dome joint facet to display and compare the specific distribution patterns. Ten cadaver specimens were used for computed tomography (CT) scans, from which densitograms were derived using CT-osteoabsorptiometry, and for mechanical indentation testing from which the penetration strength was obtained. Our results showed 2 different distribution patterns for mineral density and penetration strength. Of the 10 specimens, 6 (60%) showed bicentric maxima (anteromedially and anterolaterally), and 4 (40%) showed a monocentric maximum (either anteromedially or anterolaterally). A highly significant correlation (p < .0001) for both methods confirmed that the mineral density relied on local load characteristics. In conclusion, the biomechanical properties of the subchondral bone plate of the talar dome joint facet showed specific distribution patterns. CT-osteoabsorptiometry is a reliable method to display the mineral density distribution noninvasively. We recommend CT-osteoabsorptiometry for noninvasive analysis of the biomechanical properties of the subchondral bone plate in osteochondral joint reconstruction and the prevention and treatment of osteoarthritis and osteochondral lesions. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Comparison of the effect on bone healing process of different implants used in minimally invasive plate osteosynthesis: limited contact dynamic compression plate versus locking compression plate

    OpenAIRE

    Xue, Zichao; Xu, Haitao; Ding, Haoliang; Qin, Hui; An, Zhiquan

    2016-01-01

    Minimally invasive plate osteosynthesis (MIPO) has been widely accepted because of its satisfactory clinical outcomes. However, the implant construct that works best for MIPO remains controversial. Different plate designs result in different influence mechanisms to blood flow. In this study, we created ulnar fractures in 42 beagle dogs and fixed the fractures using MIPO. The dogs were randomly divided into two groups and were fixed with a limited contact dynamic compression plate (LC-DCP) or ...

  19. EVALUATION OF RESULTS IN FRACTURES OF BOTH BONES FOREARM TREATED WITH DYNAMIC COMPRESSION PLATING

    Directory of Open Access Journals (Sweden)

    Sindhuja G

    2017-06-01

    incisions for radius and ulna and preservation of the natural curves of radius will lessen the rate of complications. Rigid fixation of fractures after perfect anatomical reduction with 3.5 mm DCP and screws allows early mobilisation, prevents soft tissue contracture, muscular tethering and improves vascularity. A minimum of 6 cortices have to be fixed in each fracture fragment and the nearest screw to the fracture line should be at least 1 cm away. It minimises vascular damage to the plated bone segment.

  20. Loss of implant-bone interface following distal radial locking-plate endoprosthesis limb-sparing surgery in a dog.

    Science.gov (United States)

    Venzin, C; Grundmann, S; Montavon, P M

    2012-01-01

    An eight-year-old, neutered female Rottweiler was presented with lameness of seven days duration. Radiographs were consistent with a distal radial bone tumour. Limb-sparing surgery was performed using a commercially available endoprosthesis with a locking bone plate. Histopathological examination of the resected bone revealed an intraosseous fibrosarcoma, and postoperative adjuvant chemotherapy was initiated three weeks after surgery. Despite initial satisfactory limb function, lameness worsened four months after surgery. Radiographs revealed large areas of bone lysis around the proximal and distal screws, leading to significant resorption of the radius and radial carpal bone with subsequent construct failure. Further treatment was declined by the owner and the dog was subsequently euthanased. This case illustrates that implant failure is not necessarily averted by the use of locking (compared with non-locking) implants combined with an endoprosthesis to treat distal radial tumours in dogs. © 2011 British Small Animal Veterinary Association.

  1. Insulin-Like Growth Factor-Independent Effects of Growth Hormone on Growth Plate Chondrogenesis and Longitudinal Bone Growth.

    Science.gov (United States)

    Wu, Shufang; Yang, Wei; De Luca, Francesco

    2015-07-01

    GH stimulates growth plate chondrogenesis and longitudinal bone growth directly at the growth plate. However, it is not clear yet whether these effects are entirely mediated by the local expression and action of IGF-1 and IGF-2. To determine whether GH has any IGF-independent growth-promoting effects, we generated (TamCart)Igf1r(flox/flox) mice. The systemic injection of tamoxifen in these mice postnatally resulted in the excision of the IGF-1 receptor (Igf1r) gene exclusively in the growth plate. (TamCart)Igf1r(flox/flox) tamoxifen-treated mice [knockout (KO) mice] and their Igf1r(flox/flox) control littermates (C mice) were injected for 4 weeks with GH. At the end of the 4-week period, the tibial growth and growth plate height of GH-treated KO mice were greater than those of untreated C or untreated KO mice. The systemic injection of GH increased the phosphorylation of Janus kinase 2 and signal transducer and activator of transcription 5B in the tibial growth plate of the C and KO mice. In addition, GH increased the mRNA expression of bone morphogenetic protein-2 and the mRNA expression and protein phosphorylation of nuclear factor-κB p65 in both C and KO mice. In cultured chondrocytes transfected with Igf1r small interfering RNA, the addition of GH in the culture medium significantly induced thymidine incorporation and collagen X mRNA expression. In conclusion, our findings demonstrate that GH can promote growth plate chondrogenesis and longitudinal bone growth directly at the growth plate, even when the local effects of IGF-1 and IGF-2 are prevented. Further studies are warranted to elucidate the intracellular molecular mechanisms mediating the IGF-independent, growth-promoting GH effects.

  2. Orthogonal Double Plating and Autologous Bone Grafting of Postoperative Humeral Shaft Nonunion - A Rare Case Report and Review of Literature.

    Science.gov (United States)

    Metikala, Sreenivasulu; Bhogadi, Prabhudheer

    2015-01-01

    Nonunion following surgical stabilization of humeral shaft fractures, although infrequent, remains a challenge as limited surgical options are available. The difficulties in re-fixation are due to osteolysis produced by the loose implant components and disuse osteopenia of the entire bone segment. We share our experience in the management of a long standing diaphyseal nonunion of humerus following titanium LCP fixation. A 58 years old woman presented with 20 months old nonunion following titanium LCP fixation of her closed humeral shaft fracture, done elsewhere. The interesting intraoperative findings, noteworthy, are about the extensive metallosis and the gross cortical defect measuring 10cm x 1cm x 1cm, corresponding to the foot print of the previous plate with exposed medullary canal. It was managed by debridement, dual plate fixation using 9 holed and 12 holed stainless steel LCPs in an orthogonal fashion and autologous bone grafting. The nonunion healed in 5 months and she regained all the movements except for terminal 10° of elbow extension and 15° of shoulder abduction at her final follow up of 30 months. According to Stewart and Hundley classification the final result was found to be good. We recommend the judicious use of long and short plates in 90-90 orientation along with autogenous bone grafting in the management of a long standing humeral shaft nonunion having extensive cortical resorption following surgical stabilization by plating.

  3. [Augmentative locking compression plate (LCP) combined with bone graft for the treatment of aseptic femoral shaft nonunion after intramedullary nailing].

    Science.gov (United States)

    Wang, Fei-da; Gao, Yao-zu; Yuan, Wei; Du, Jin-qiang; Wei, Xiao-chun

    2014-10-01

    To investigate the effect of augmentative locking compression plate combined with bone graft in treating aseptic femoral shaft nonunion after intramedullary nailing. Twenty-one cases with aseptic femoral shaft nonunion after intramedullary nailing from January 2007 to January 2013 were treated,including 18 males and 3 females with a mean age of 37.7 years (ranged from 23 to 64 years). The mean period of nonunion after surgery was 23.9 months (ranged from 9 to 62 months). According to Weber-Cech classification,10 of those 21 cases were hypertrophic nonunion,7 were atrophic, and 4 had oligotrophic fracture nonunion. All patients retained the original intramedullary nail, and applied with augmentation plating of 6 to 8 holes locking compression plate, unicortical fixation with 2 to 3 locking screws in the proximal or distal end, with simultaneous autologous iliac bone grafting. After treatment,all patients were allowed to partial weight-bearing until full weight-bearing according to the radiological results. All patients were followed up and were evaluated with clinical and imaging results. All patients were followed up from 8 to 24 months, averaged (13.5±3.5) months,which showed clinical union at 4 to 8 months, averaged (6.0±1.0) months and radiological solid union at 7 to 12 months, averaged (9.1±1.5) months. No such complications as infection,hardware loosening or breaking were found. Augmentative locking compression plate(LCP) combined with bone graft for aseptic femoral shaft nonunion after intramedullary nail has a satisfied clinical efficacy. It's an useful and simple method.

  4. Patient-tailored plate for bone fixation and accurate 3D positioning in corrective osteotomy

    NARCIS (Netherlands)

    Dobbe, J. G. G.; Vroemen, J. C.; Strackee, S. D.; Streekstra, G. J.

    2013-01-01

    A bone fracture may lead to malunion of bone segments, which gives discomfort to the patient and may lead to chronic pain, reduced function and finally to early osteoarthritis. Corrective osteotomy is a treatment option to realign the bone segments. In this procedure, the surgeon tries to improve

  5. Coracoid bone graft osteolysis after Latarjet procedure: A comparison study between two screws standard technique vs mini-plate fixation

    Science.gov (United States)

    Giacomo, Giovanni Di; Costantini, Alberto; de Gasperis, Nicola; De Vita, Andrea; Lin, Bernard K. H.; Francone, Marco; Beccaglia, Mario A. Rojas; Mastantuono, Marco

    2013-01-01

    Aims: One of the reason for Latarjet procedure failure may be coracoid graft osteolysis. In this study, we aimed to understand if a better compression between the coracoid process and the glenoid, using a mini-plate fixation during the Latarjet procedure, could reduce the amount of coracoid graft osteolysis. Materials and Methods: A computed tomography scan analysis of 26 prospectively followed-up patients was conducted after modified Latarjet procedure using mini-plate fixation technique to determine both the location and the amount of coracoid graft osteolysis in them. We then compared our current results with results from that of our previous study without using mini-plate fixation to determine if there is any statistical significant difference in terms of corcacoid bone graft osteolysis between the two surgical techniques. Results: The most relevant osteolysis was represented by the superficial part of the proximal coracoid, whereas the deep part of the proximal coracoid graft is least involved in osteolysis and has best bone healing. The current study showed a significant difference only for the deep part of the distal coracoid with our previous study (P Latarjet procedure. Conclusion: Our study suggests that there is a significant difference only for the deep part of the distal coracoid in terms of osteolysis. At clinical examination, this difference did not correspond with any clinical findings. Level of Evidence: Level 4. Clinical Relevance: Prospective case series, Treatment study. PMID:23858288

  6. Medial support by fibula bone graft in angular stable plate fixation of proximal humeral fractures: an in vitro study with synthetic bone.

    Science.gov (United States)

    Osterhoff, Georg; Baumgartner, Daniel; Favre, Philippe; Wanner, Guido A; Gerber, Hans; Simmen, Hans-Peter; Werner, Clément M L

    2011-07-01

    Failure to achieve stable fixation with medial support in proximal humeral fractures can result in varus malalignment and cut-through of the proximal screws. The purpose of this study was to investigate the influence of an intramedullary fibula bone graft on the biomechanical properties of proximal humeral fractures stabilized by angular stable plate fixation in a bone model under cyclic loading. Two fixation techniques were tested in 20 composite analog humeri models. In group F- (n = 10), fractures were fixed by an anatomically formed locking plate system. In group F+ (n = 10), the same fixation system was used with an additional fibular graft model with a length of 6 cm inserted in an intramedullary manner. Active abduction was simulated for 400 cycles by use of a recently established testing setup. Fragment gap distance was measured, and thereby, intercyclic motion, fragment migration, and residual plastic deformation were determined. The addition of a fibular graft to the fixation plate led to 5 times lower intercyclic motion, 2 times lower fragment migration, and 2 times less residual plastic deformation. Neither screw pullout, cut-through, nor implant failure was observed. Medial support with an intramedullary fibular graft in an angular stable fixation of the proximal humerus in vitro increases overall stiffness of the bone-implant construct and reduces migration of the humeral head fragment. This technique might provide a useful tool in the treatment of displaced proximal humeral fractures, especially when there is medial comminution. Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  7. Horizontal mucosal thickness at implant sites as it correlates with the integrity and thickness of the buccal bone plate.

    Science.gov (United States)

    Schwarz, Frank; Sager, Martin; Golubovic, Vladimir; Iglhaut, Gerhard; Becker, Kathrin

    2016-10-01

    To histologically assess the association between the horizontal mucosal thickness (MT) at implant sites with the integrity and thickness of the buccal bone plate in a canine model. Two-piece titanium implants were placed at chronic-type lateral ridge defects. The resulting vestibular dehiscence-type defects (vertical dimensions of 2-8 mm) were left untreated. After a submerged healing period of 2 and 8 weeks (n = 6 fox hounds each), dissected blocks were processed for histomorphometrical analyses [e.g. MT, bone thickness (BT) and residual defect length]. Linear regression revealed significant associations between vestibular MT and BT values after 2 (R 2  = 0.22, B = -0.37, P R 2  = 0.37, B = -0.45, P < 0.001) of healing. The present analysis has pointed to an inverse relationship between horizontal MT and BT values at the vestibular aspect of submerged titanium implants. MT was most pronounced in the absence of a buccal bone plate. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Finite element modeling for development and optimization of a bone plate for mandibular fracture in dogs.

    Science.gov (United States)

    Freitas, Elisângela P; Rahal, Sheila C; Gioso, Marco Antonio; Vulcano, Luiz Carlos; Shimano, Antonio Carlos; da Silva, Jorge Vicente Lopes; Noritomi, Pedro Y; El Warrak, Alexander O

    2010-01-01

    This study aimed to develop a plate to treat fractures of the mandibular body in dogs and to validate the project using finite elements and biomechanical essays. Mandible prototypes were produced with 10 oblique ventrorostral fractures (favorable) and 10 oblique ventrocaudal fractures (unfavorable). Three groups were established for each fracture type. Osteosynthesis with a pure titanium plate of double-arch geometry and blocked monocortical screws of free angulation were used. The mechanical resistance of the prototype with unfavorable fracture was lower than that of the favorable fracture. In both fractures, the deflection increased and the relative stiffness decreased proportionally to the diminishing screw number The finite element analysis validated this plate study, since the maximum tension concentration observed on the plate was lower than the resistance limit tension admitted by the titanium. In conclusion, the double-arch geometry plate fixed with blocked monocortical screws has sufficient resistance to stabilize oblique fractures, without compromising mandibular dental or neurovascular structures.

  9. Radiographic outcome and complications of tibial plateau leveling osteotomy stabilized with an anatomically contoured locking bone plate.

    Science.gov (United States)

    Kowaleski, Michael P; Boudrieau, Randy J; Beale, Brian S; Piras, Alessandro; Hulse, Donald; Johnson, Kenneth A

    2013-10-01

    To evaluate the short-term clinical performance of an anatomically pre-contoured, locking plate in dogs undergoing tibial plateau leveling osteotomy (TPLO) for cranial cruciate ligament (CrCL) disease. Prospective, multi-center clinical study. Dogs (n = 56) undergoing TPLO. Signalment and operative data were recorded. Preoperative, postoperative, and follow-up tibial plateau angle (TPA) were measured from radiographic images. Intraoperative and postoperative complications were recorded; the latter were categorized as minor if additional surgery was not necessary, and major if surgery was needed to resolve the complication. Bone healing was scored and change in tibial plateau angle (TPACH ) between postoperative and follow up radiographic images was calculated. Mean (± SD) preoperative TPA was 28.6 ± 3.8°, and mean postoperative TPA was 4.8 ± 1.9°. Four intraoperative complications (7.1%) including 2 cases of intra-articular screw placement, 3 minor postoperative complications (5.4%), and no major or catastrophic postoperative complications occurred. Median bone healing grade was 4/4 (excellent union >75% healing). Mean TPACH was 0.15 ± 1.32°. Use of this anatomically contoured, locking TPLO plate by experienced surgeons is associated with accurate tibial plateau leveling, reliably excellent bone union at follow-up exam, minimal TPACH , and a lower complication rate than previously reported. Confining contouring to the distal shaft of the plate ensures there is precise apposition to the tibial diaphysis and mitigates the risk of intra-articular screw placement. © Copyright 2013 by The American College of Veterinary Surgeons.

  10. Posttraumatic tibia valga: a case demonstrating asymmetric activity at the proximal growth plate on technetium bone scan

    International Nuclear Information System (INIS)

    Zionts, L.E.; Harcke, H.T.; Brooks, K.M.; MacEwen, G.D.

    1987-01-01

    Posttraumatic tibia valga is a well-recognized complication following fracture of the upper tibial metaphysis in young children. We present a case of a child who developed a valgus deformity following fracture of the proximal tibia and fibula in which quantitative bone scintigraphy at 5 months after injury demonstrated increased uptake at the proximal tibial growth plate with proportionally greater uptake on the medial side. This finding suggests that the valgus deformity in this patient was due to a relative increase in vascularity and consequent overgrowth of the medial portion of the proximal tibial physis

  11. Posttraumatic tibia valga: a case demonstrating asymmetric activity at the proximal growth plate on technetium bone scan

    Energy Technology Data Exchange (ETDEWEB)

    Zionts, L.E.; Harcke, H.T.; Brooks, K.M.; MacEwen, G.D.

    1987-07-01

    Posttraumatic tibia valga is a well-recognized complication following fracture of the upper tibial metaphysis in young children. We present a case of a child who developed a valgus deformity following fracture of the proximal tibia and fibula in which quantitative bone scintigraphy at 5 months after injury demonstrated increased uptake at the proximal tibial growth plate with proportionally greater uptake on the medial side. This finding suggests that the valgus deformity in this patient was due to a relative increase in vascularity and consequent overgrowth of the medial portion of the proximal tibial physis.

  12. Plate fixation and bone grafting of distal clavicle nonunions: radiologic and functional outcomes

    NARCIS (Netherlands)

    Villa, Jordan C.; van der List, Jelle P.; Gausden, Elizabeth B.; Lorich, Dean G.; Helfet, David L.; Kloen, Peter; Wellman, David S.

    2016-01-01

    The optimal treatment for distal clavicle nonunions remains unknown. Small series have reported outcomes following distal fragment excision and various fixation techniques. We present the clinical, radiographic and functional outcomes after superior plating or double (superior and anteroinferior)

  13. Autologous grafts of double-strut fibular cortical bone plate to treat the fractures and defects of distal femur: a case report and review of literature

    Directory of Open Access Journals (Sweden)

    CHEN Xu

    2012-02-01

    Full Text Available 【Abstract】We reported a 23-year-old man who was involved in a high-speed motorcycle accident. He sustained a closed fracture at the right distal femur. The primary fracture happened on February 2008. He underwent open reduction and internal fixation with cloverleaf plate. And one hundred days after the surgery, the proximal screws were pulled-out, but the bone union was not achieved. Treatment consisted of exchanging the cloverleaf plate with a locking compression plate and using an auto-iliac bone graft to fill the nonunion gap. In July 2009, the patient had a sharp pain in the right lower limb. The X-ray revealed that the plate implanted last year was broken, causing a nonunion at the fracture site. Immediately the plate and screws were removed and an intramedullary nail was inserted reversely from the distal femur as well as a 7 cm long bone from the right fibula was extracted and longitudinally split into two pieces to construct cortical bone plates. Then we placed them laterally and medially to fracture site, drilled two holes respectively, and fastened them with suture. We carried on auto-iliac bone grafting with the nonunion bone grafts. The follow-up at 15 months after operation showed that the treatment was successful, X-ray confirmed that there was no rotation and no angular or short deformity. We briefly reviewed the literature regarding such an unusual presentation and discussed in details the possible etiology and the advantages of autologous double-strut fibular grafts to cope with such an intractable situation. Key words: Femur; Transplantation, autologous; Bone screws

  14. The use of titanium plates for bone regeneration with root form implants: a case report.

    Science.gov (United States)

    Maksoud, M A

    1999-01-01

    In reconstruction of the partially and totally edentulous ridges that have bony defects due to old trauma or longstanding atrophy, it is necessary to reconstruct both the width and height of the alveolar ridge. This clinical case report covers bone regeneration prior to implant placement to achieve an aesthetic and functional base for prosthetic restoration. The focus of this report will be on bone regeneration, which does not depend on the utilization of a barrier membrane.

  15. Longitudinal bone growth is impaired by direct involvement of caffeine with chondrocyte differentiation in the growth plate.

    Science.gov (United States)

    Choi, Hyeonhae; Choi, Yuri; Kim, Jisook; Bae, Jaeman; Roh, Jaesook

    2017-01-01

    We showed previously that caffeine adversely affects longitudinal bone growth and disrupts the histomorphometry of the growth plate during the pubertal growth spurt. However, little attention has been paid to the direct effects of caffeine on chondrocytes. Here, we investigated the direct effects of caffeine on chondrocytes of the growth plate in vivo and in vitro using a rapidly growing young rat model, and determined whether they were related to the adenosine receptor signaling pathway. A total of 15 male rats (21 days old) were divided randomly into three groups: a control group and two groups fed caffeine via gavage with 120 and 180 mg kg -1  day -1 for 4 weeks. After sacrifice, the tibia processed for the analysis of the long bone growth and proliferation of chondrocytes using tetracycline and BrdU incorporation, respectively. Caffeine-fed animals showed decreases in matrix mineralization and proliferation rate of growth plate chondrocytes compared with the control. To evaluate whether caffeine directly affects chondrocyte proliferation and chondrogenic differentiation, primary rat chondrocytes were isolated from the growth plates and cultured in either the presence or absence of caffeine at concentrations of 0.1-1 mm, followed by determination of the cellular proliferation or expression profiles of cellular differentiation markers. Caffeine caused significant decreases in extracellular matrix production, mineralization, and alkaline phosphatase activity, accompanied with decreases in gene expression of the cartilage-specific matrix proteins such as aggrecan, type II collagen and type X. Our results clearly demonstrate that caffeine is capable of interfering with cartilage induction by directly inhibiting the synthetic activity and orderly expression of marker genes relevant to chondrocyte maturation. In addition, we found that the adenosine type 1 receptor signaling pathway may be partly involved in the detrimental effects of caffeine on chondrogenic

  16. Effect of four-corner fusion with locking plate without bone graft on functional recovery of the wrist: New treatment guidelines

    OpenAIRE

    Tielemans, Alexandre; Van Innis, Fernand; Troussel, Serge; Detrembleur, Christine; Libouton, Xavier; Lequint, Thierry

    2017-01-01

    We assessed the effect of four-corner intercarpal fusion with locking plate without bone graft on daily activities and pain in patients with stage II and III scapholunate advanced collapse and scaphoid nonunion. Twenty-one patients who underwent four-corner fusion with scaphoidectomy without bone graft were evaluated with the Disabilities of the Arm, Shoulder and Hand (QuickDASH) and Visual Analog Scale (VAS) pain scores before and 16 months after surgery. We also compared postoperative grip ...

  17. Mechanical analysis of transversal iliac fracture stabilization using dynamic compression plate or screws and PMM in polyurethane bone model

    Directory of Open Access Journals (Sweden)

    T.C. Prada

    Full Text Available ABSTRACT Pelvic fractures correspond to 20 to 30 % of the fractures observed in dogs. Complete fractures, especially with bone axis deviation should be surgically treated. The mechanical study of surgical techniques is of utmost importance to assess the best way of treating these injuries. This study compared, biomechanically, the use of a dynamic compression plate (DCP and screws (group 1 or screws and polymethylmethacrylate (PMMA (group 2 to stabilize an iliac fracture using a static test. Sixteen canine synthetic hemi-pelvises (test specimens with a transverse iliac osteotomy were used. After fixation with implants, a load was applied to the acetabulum until failure. Group 1 maximal compressive load was 133.9±18.60 N, displacement at yield 21.10±3.59mm and stiffness 125.22±12.25N/mm. Group 2 maximal compressive load was 183.50±27.38N, displacement at yield 16.66±5.42mm and stiffness 215.68±33.34N/mm. The stabilization with polymethylmethacrylate was stronger than dynamic compression plate since it resisted a greater load in all test specimens.

  18. Simulation of ultrasonic wave propagation in anisotropic poroelastic bone plate using hybrid spectral/finite element method.

    Science.gov (United States)

    Nguyen, Vu-Hieu; Naili, Salah

    2012-08-01

    This paper deals with the modeling of guided waves propagation in in vivo cortical long bone, which is known to be anisotropic medium with functionally graded porosity. The bone is modeled as an anisotropic poroelastic material by using Biot's theory formulated in high frequency domain. A hybrid spectral/finite element formulation has been developed to find the time-domain solution of ultrasonic waves propagating in a poroelastic plate immersed in two fluid halfspaces. The numerical technique is based on a combined Laplace-Fourier transform, which allows to obtain a reduced dimension problem in the frequency-wavenumber domain. In the spectral domain, as radiation conditions representing infinite fluid halfspaces may be exactly introduced, only the heterogeneous solid layer needs to be analyzed by using finite element method. Several numerical tests are presented showing very good performance of the proposed procedure. A preliminary study on the first arrived signal velocities computed by using equivalent elastic and poroelastic models will be presented. Copyright © 2012 John Wiley & Sons, Ltd.

  19. The treatment of femoral bone loss by axial external fixation and susbequent locking plate application: a case report.

    Science.gov (United States)

    Boero, Emanuele; Mogollo, Maria del Amparo Paredes

    2015-12-01

    A 20-year-old man was admitted to our hospital having sustianed bilateral high-energy femoral fractures. The right femoral fracture was an open grade 3B with OTA grade 3 bone loss. The patient had also a brain contusion with a subdural haematoma and a closed fracture of the left clavicle. Initial management included temporarily stabilisation of the femoral fractures wth external fixators and prompt transfer to the intensive care unit. Three weeks later the external fixator of the right femur was converted to an hybrid system, and the fixator of the left side was removed and a reamed intramedullary locking nail was applied. Two months after the accident the patient underwent bone transport (11 cm long) of the right femur with an monolateral external fixation. When the final length was achieved there were knee stiffness (ROM 0° to 30°) and non-union of the docking site. Therefore, the patient underwent a Judet's procedure to treat the knee stiffness and stabilisation of the non united femur with a locking plate (LISS). After the operation the patient started progressive weight bearing. A year after trauma and following union of the femur, the patient underwent soft tissue reconstruction of the anterior side of the thigh with a free vascularised flap. At final follow upo the patient had a good functional recovery with return to his previous occupation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Bone quality and growth characteristics of growth plates following limb transplantation between animals of different ages - Results of an experimental study in male syngeneic rats

    Directory of Open Access Journals (Sweden)

    Park Young-Hwan

    2011-10-01

    Full Text Available Abstract Introduction The purpose of this study was to identify graft osteoporosis post transplantation by micro-CT analysis, and the growth potential of growth plates in the transplanted limb. Methods Ten juvenile to juvenile and five juvenile to adult hind limb transplants were performed in male syngeneic Lewis rats. Upper tibial bone density in isochronograft and heterochronograft limbs was measured by 3D micro-CT and compared with that of the opposite non-operated limbs. Results We observed inferior bone quality (p Conclusions Age dependent alterations affect bone quality, resulting in post transplantation osteoporosis in heterochronografts, but not isochronografts. However, the growth plates of transplanted limbs retain their properties of longitudinal growth and continue to grow at the same rate.

  1. Bioabsorbable bone fixation plates for X-ray imaging diagnosis by a radiopaque layer of barium sulfate and poly(lactic-co-glycolic acid).

    Science.gov (United States)

    Choi, Sung Yoon; Hur, Woojune; Kim, Byeung Kyu; Shasteen, Catherine; Kim, Myung Hun; Choi, La Mee; Lee, Seung Ho; Park, Chun Gwon; Park, Min; Min, Hye Sook; Kim, Sukwha; Choi, Tae Hyun; Choy, Young Bin

    2015-04-01

    Bone fixation systems made of biodegradable polymers are radiolucent, making post-operative diagnosis with X-ray imaging a challenge. In this study, to allow X-ray visibility, we separately prepared a radiopaque layer and attached it to a bioabsorbable bone plate approved for clinical use (Inion, Finland). We employed barium sulfate as a radiopaque material due to the high X-ray attenuation coefficient of barium (2.196 cm(2) /g). The radiopaque layer was composed of a fine powder of barium sulfate bound to a biodegradable material, poly(lactic-co-glycolic acid) (PLGA), to allow layer degradation similar to the original Inion bone plate. In this study, we varied the mass ratio of barium sulfate and PLGA in the layer between 3:1 w/w and 10:1 w/w to modulate the degree and longevity of X-ray visibility. All radiopaque plates herein were visible via X-ray, both in vitro and in vivo, for up to 40 days. For all layer types, the radio-opacity decreased with time due to the swelling and degradation of PLGA, and the change in the layer shape was more apparent for layers with a higher PLGA content. The radiopaque plates released, at most, 0.5 mg of barium sulfate every 2 days in a simulated in vitro environment, which did not appear to affect the cytotoxicity. The radiopaque plates also exhibited good biocompatibility, similar to that of the Inion plate. Therefore, we concluded that the barium sulfate-based, biodegradable plate prepared in this work has the potential to be used as a fixation device with both X-ray visibility and biocompatibility. © 2014 Wiley Periodicals, Inc.

  2. Conditional inactivation of TNFα-converting enzyme in chondrocytes results in an elongated growth plate and shorter long bones.

    Directory of Open Access Journals (Sweden)

    Kenta Saito

    Full Text Available TNFα-converting enzyme (TACE is a membrane-bound proteolytic enzyme with essential roles in the functional regulation of TNFα and epidermal growth factor receptor (EGFR ligands. Previous studies have demonstrated critical roles for TACE in vivo, including epidermal development, immune response, and pathological neoangiogenesis, among others. However, the potential contribution of TACE to skeletal development is still unclear. In the present study, we generated a Tace mutant mouse in which Tace is conditionally disrupted in chondrocytes under the control of the Col2a1 promoter. These mutant mice were fertile and viable but all exhibited long bones that were approximately 10% shorter compared to those of wild-type animals. Histological analyses revealed that Tace mutant mice exhibited a longer hypertrophic zone in the growth plate, and there were fewer osteoclasts at the chondro-osseous junction in the Tace mutant mice than in their wild-type littermates. Of note, we found an increase in osteoprotegerin transcripts and a reduction in Rankl and Mmp-13 transcripts in the TACE-deficient cartilage, indicating that dysregulation of these genes is causally related to the skeletal defects in the Tace mutant mice. Furthermore, we also found that phosphorylation of EGFR was significantly reduced in the cartilage tissue lacking TACE, and that suppression of EGFR signaling increases osteoprotegerin transcripts and reduces Rankl and Mmp-13 transcripts in primary chondrocytes. In accordance, chondrocyte-specific abrogation of Egfr in vivo resulted in skeletal defects nearly identical to those observed in the Tace mutant mice. Taken together, these data suggest that TACE-EGFR signaling in chondrocytes is involved in the turnover of the growth plate during postnatal development via the transcriptional regulation of osteoprotegerin, Rankl, and Mmp-13.

  3. Orthogonal Double Plating and Autologous Bone Grafting of Postoperative Humeral Shaft Nonunion – A Rare Case Report and Review of Literature

    Science.gov (United States)

    Metikala, Sreenivasulu; Bhogadi, Prabhudheer

    2015-01-01

    Introduction: Nonunion following surgical stabilization of humeral shaft fractures, although infrequent, remains a challenge as limited surgical options are available. The difficulties in re-fixation are due to osteolysis produced by the loose implant components and disuse osteopenia of the entire bone segment. We share our experience in the management of a long standing diaphyseal nonunion of humerus following titanium LCP fixation. Case Report: A 58 years old woman presented with 20 months old nonunion following titanium LCP fixation of her closed humeral shaft fracture, done elsewhere. The interesting intraoperative findings, noteworthy, are about the extensive metallosis and the gross cortical defect measuring 10cm x 1cm x 1cm, corresponding to the foot print of the previous plate with exposed medullary canal. It was managed by debridement, dual plate fixation using 9 holed and 12 holed stainless steel LCPs in an orthogonal fashion and autologous bone grafting. The nonunion healed in 5 months and she regained all the movements except for terminal 10° of elbow extension and 15° of shoulder abduction at her final follow up of 30 months. According to Stewart and Hundley classification the final result was found to be good. Conclusion: We recommend the judicious use of long and short plates in 90-90 orientation along with autogenous bone grafting in the management of a long standing humeral shaft nonunion having extensive cortical resorption following surgical stabilization by plating. PMID:27299099

  4. Postnatal administration of 2-oxoglutaric acid improves articular and growth plate cartilages and bone tissue morphology in pigs prenatally treated with dexamethasone.

    Science.gov (United States)

    Tomaszewska, E; Dobrowolski, P; Wydrych, J

    2012-10-01

    The potential effects of prenatal administration of dexamethasone (DEX) and postnatal treatment with 2-oxoglutaric acid (2-Ox) on postnatal development of connective tissue of farm animals were not examined experimentally. The aim of this study was to establish changes in morphological parameters of bone and articular and growth plate cartilages damaged by the prenatal action of DEX in piglets supplemented with 2-Ox. The 3 mg of DEX was administered by intramuscular route every second day from day 70 of pregnancy to parturition and then piglets were supplemented with 2-Ox during 35 days of postnatal life (0.4 g/kg body weight). The mechanical properties, BMD and BMC of bones, and histomorphometry of articular and growth plate cartilages were determined. Maternal treatment with DEX decreased the weight by 48%, BMD by 50% and BMC by 61% of the tibia in male piglets while such action of DEX in female piglets was not observed. DEX led to thinning of articular and growth plate cartilages and trabeculae thickness and reduced the serum GH concentration in male piglets. The administration of 2-Ox prevented the reduction of trabeculae thickness, the width of articular and growth plate cartilages in male piglets connected with higher growth hormone concentration compared with non-supplemented male piglets. The result showed that the presence of 2-Ox in the diet had a positive effect on the development of connective tissue in pigs during suckling and induced a complete recovery from bone and cartilage damage caused by prenatal DEX action.

  5. Computational modelling of long bone fractures fixed with locking plates - How can the risk of implant failure be reduced?

    LENUS (Irish Health Repository)

    Nassiri, M

    2013-03-01

    The Locking Compression Plate (LCP) is part of a new plate generation requiring an adapted surgical technique and new thinking about commonly used concepts of internal fixation using plates. Knowledge of the fixation stability provided by these new plates is very limited and clarification is still necessary to determine how the mechanical stability and the risk of implant failure can best be controlled.

  6. The challenge of non-union in subtrochanteric fractures with breakage of intramedullary nail: evaluation of outcomes in surgery revision with angled blade plate and allograft bone strut.

    Science.gov (United States)

    Rollo, G; Tartaglia, N; Falzarano, G; Pichierri, P; Stasi, A; Medici, A; Meccariello, L

    2017-12-01

    Subtrochanteric fractures have a bimodal age distribution. They usually require open reduction and internal fixation. Closed reduction and intramedullary nail fixation rate are increased for this type of fracture. As a result, the hardware breakage and non-union rate is high among such patients. Our purpose is to evaluate the outcomes of the role of blade plate and bone strut allograft in the management of subtrochanteric non-union by femoral nailing. We reported a group of 22 patients with subtrochanteric non-union, associated with breakage of the intramedullary nail with medial femoral allograft bone and lateral blade plate and wire (PS) s; and a group of 13 patients with subtrochanteric non-union, associated with breakage of the intramedullary nail treated with lateral blade plate and screws (CG). The chosen criteria to evaluate the two group during the clinical and radiological follow-up were the quality of life, measured by The Short Form (12) Health Survey (SF-12), the hip function and quality of life related to it, measured by the Harris Hip Score (HHS), bone healing, measured by Radiographic Union Score (RUS) by XR and CT at 1 year after the surgery, and postoperative complications. The evaluation endpoint was set at 12 months. The Bone healing measured by RUS occurred and also the full recovery before the first trauma measured by SF-12 and HHS are better in PS group. We only had three unimportant complications in PS while four breakage hardware in CG. We conclude that in complicated non-unions, the use of blade plate and bone strut allograft has a definite positive role in the management of such cases.

  7. Effect of four-corner fusion with locking plate without bone graft on functional recovery of the wrist: New treatment guidelines.

    Science.gov (United States)

    Tielemans, A; Van Innis, F; Troussel, S; Detrembleur, C; Libouton, X; Lequint, T

    2017-06-01

    We assessed the effect of four-corner intercarpal fusion with locking plate without bone graft on daily activities and pain in patients with stage II and III scapholunate advanced collapse and scaphoid nonunion. Twenty-one patients who underwent four-corner fusion with scaphoidectomy without bone graft were evaluated with the Disabilities of the Arm, Shoulder and Hand (QuickDASH) and Visual Analog Scale (VAS) pain scores before and 16 months after surgery. We also compared postoperative grip strength between the operated and the healthy side. A principal component analysis was used to establish the relationship between functional benefit, immobilization period and number of physiotherapy sessions. We compared our results with published data. VAS and QuickDASH scores improved significantly. Loss of strength was observed postoperatively. QuickDASH score improved the most with a short immobilization period. No significant difference was found relative to the literature for follow-up time, range of motion, grip strength and QuickDASH score. All patients had bone fusion after 1 year. Four-corner fusion with locking plate is a procedure that reduces pain and improves functional scores. Our results are equal to those reported in the literature with bone graft. The union rate seemed high despite the absence of bone graft but was only assessed by x rays. This study allowed us to establish a treatment guideline: a shorter immobilization leads to better recovery. Copyright © 2017. Published by Elsevier Masson SAS.

  8. The Effect of Polymethyl Methacrylate Augmentation on the Primary Stability of Cannulated Bone Screws in an Anterolateral Plate in Osteoporotic Vertebrae: A Human Cadaver Study

    Science.gov (United States)

    Rüger, Matthias; Sellei, Richard M.; Stoffel, Marcus; von Rüden, Christian

    2015-01-01

    Study Design Cohort study. Objective Expandable anterolateral plates facilitate the reduction of posttraumatic deformities of thoracolumbar spine injuries and are commonly used in cases of unstable injuries or compromised bone quality. In this in vitro study, the craniocaudal yield load of the osseous fixation of an anterior angular stable plate fixation system and the effect of polymethyl methacrylate (PMMA) screw augmentation on the primary stability of the screw–bone interface during kyphosis reduction was evaluated in 12 osteoporotic human thoracolumbar vertebrae. Methods The anterolateral stabilization device used for this study is comprised of two swiveling flanges and an expandable midsection. It facilitates the controlled reduction of kyphotic deformities in situ with a geared distractor. Single flanges were attached to 12 thoracolumbar vertebrae. Six specimens were augmented with PMMA by means of cannulated bone screws. The constructs were subjected to static, displacement-controlled craniocaudal loading to failure in a servohydraulic testing machine. Results The uncemented screws cut out at a mean 393 ± 66 N, whereas the cemented screws showed significantly higher yield load of 966 ± 166 N (p < 0.02). We detected no significant correlation between bone mineral density and yield load in this setting. Conclusion Our results indicate that PMMA augmentation is an effective method to increase two- to threefold the primary stability of the screw–bone interface of an anterolateral spine stabilization system in osteoporotic bone. We recommend it in cases of severely compromised bone quality to reduce the risk of screw loosening during initial kyphosis correction and to increase long-term construct stability. PMID:26835201

  9. Effect of stainless steel and titanium low-contact dynamic compression plate application on the vascularity and mechanical properties of cortical bone after fracture.

    Science.gov (United States)

    Jain, R; Podworny, N; Hearn, T; Anderson, G I; Schemitsch, E H

    1997-10-01

    Comparison of the effect of stainless steel and titanium low-contact dynamic compression plate application on the vascularity and mechanical properties of cortical bone after fracture. Randomized, prospective. Orthopaedic research laboratory. Ten large (greater than twenty-five kilogram) adult dogs. A short, midshaft spiral tibial fracture was created, followed by lag screw fixation and neutralization with an eight-hole, 3.5-millimeter, low-contact dynamic compression plate (LCDCP) made of either 316L stainless steel (n = five) or commercially pure titanium (n = five). After surgery, animals were kept with unrestricted weight-bearing in individual stalls for ten weeks. Cortical bone blood flow was assessed by laser Doppler flowmetry using a standard metalshafted probe (Periflux Pf303, Perimed, Jarfalla, Sweden) applied through holes in the custom-made LCDCPs at five sites. Bone blood flow was determined at four times: (a) prefracture, (b) postfracture, (c) postplating, and (d) ten weeks postplating. After the dogs were killed, the implant was removed and both the treated tibia and contralateral tibia were tested for bending stiffness and load to failure. Fracture creation decreased cortical perfusion in both groups at the fracture site (p = 0.02). The application of neither stainless steel nor titanium LCDCPs further decreased cortical bone blood flow after fracture creation. However, at ten weeks postplating, cortical perfusion significantly increased compared with acute postplating levels in the stainless steel (p = 0.003) and titanium (p = 0.001) groups. Cortical bone blood flow ten weeks postplating was not significantly different between the titanium group and the stainless steel group. Biomechanical tests performed on the tibiae with the plates removed did not reveal any differences in bending stiffness nor load required to cause failure between the two groups. Both titanium and stainless steel LCDCPs were equally effective in allowing revascularization, and

  10. Characterization of trabecular bone plate-rod microarchitecture using multirow detector CT and the tensor scale: Algorithms, validation, and applications to pilot human studies

    Science.gov (United States)

    Saha, Punam K.; Liu, Yinxiao; Chen, Cheng; Jin, Dakai; Letuchy, Elena M.; Xu, Ziyue; Amelon, Ryan E.; Burns, Trudy L.; Torner, James C.; Levy, Steven M.; Calarge, Chadi A.

    2015-01-01

    Purpose: Osteoporosis is a common bone disease associated with increased risk of low-trauma fractures leading to substantial morbidity, mortality, and financial costs. Clinically, osteoporosis is defined by low bone mineral density (BMD); however, increasing evidence suggests that trabecular bone (TB) microarchitectural quality is an important determinant of bone strength and fracture risk. A tensor scale based algorithm for in vivo characterization of TB plate-rod microarchitecture at the distal tibia using multirow detector CT (MD-CT) imaging is presented and its performance and applications are examined. Methods: The tensor scale characterizes individual TB on the continuum between a perfect plate and a perfect rod and computes their orientation using optimal ellipsoidal representation of local structures. The accuracy of the method was evaluated using computer-generated phantom images at a resolution and signal-to-noise ratio achievable in vivo. The robustness of the method was examined in terms of stability across a wide range of voxel sizes, repeat scan reproducibility, and correlation between TB measures derived by imaging human ankle specimens under ex vivo and in vivo conditions. Finally, the application of the method was evaluated in pilot human studies involving healthy young-adult volunteers (age: 19 to 21 yr; 51 females and 46 males) and patients treated with selective serotonin reuptake inhibitors (SSRIs) (age: 19 to 21 yr; six males and six females). Results: An error of (3.2% ± 2.0%) (mean ± SD), computed as deviation from known measures of TB plate-width, was observed for computer-generated phantoms. An intraclass correlation coefficient of 0.95 was observed for tensor scale TB measures in repeat MD-CT scans where the measures were averaged over a small volume of interest of 1.05 mm diameter with limited smoothing effects. The method was found to be highly stable at different voxel sizes with an error of (2.29% ± 1.56%) at an in vivo voxel size

  11. Investigating the effect of remodelling signal type on the finite element based predictions of bone remodelling around the thrust plate prosthesis: a patient-specific comparison.

    Science.gov (United States)

    Schmitz, M J; Clift, S E; Taylor, W R; Hertig, D; Warner, M D; Ploeg, H L; Bereiter, H

    2004-01-01

    The resorption of bone in the human femur following total hip arthroplasty is recognized to be related to the loading in the bone surrounding the prosthesis. However, the precise nature of the mechanical signal that influences the biological remodelling activity of the bone is not completely understood. In this study, a validated finite element modelling methodology was combined with a numerical algorithm to simulate the biological changes over time. This was used to produce bone remodelling predictions for an implanted thrust plate prosthesis (Centerpulse Orthopedics Limited) in a patient specific bone model. The analysis was then repeated using different mechanical signals to drive the remodelling algorithm. The results of these simulations were then compared to the patient-specific clinical data, to distinguish which of the candidate signals produced predictions consistent with the clinical evidence. Good agreement was found for a range of strain energy based signals and also deviatoric remodelling signals. The results, however, did not support the use of compressive dilatational strain as a candidate remodelling signal.

  12. TO EVALUATE THE SURGICAL OUTCOME OF NON-UNION CLAVICLE USING PLATE AND SLIVERS OF AUTOLOGOUS ILIAC CREST CORTICOCANCELLOUS BONE GRAFT

    Directory of Open Access Journals (Sweden)

    Mohammed

    2016-03-01

    Full Text Available INTRODUCTION Clavicle fracture is one of the most common fracture presenting to the fracture clinic, accounting for about 5-10% of all the adult trauma reported but still the controversy exists with regards to the definitive management. AIM To evaluate the surgical outcome of nonunion clavicle in patients treated previously with surgical management or conservative management, using plate and slivers of autologous iliac crest corticocancellous bone. DESIGN Retrospective analysis of patients operated between May 2005 and February 2013 for nonunion of the clavicle. METHODS AND MATERIALS Twenty patients who were operated between May 2005 and February 2013 for nonunion of the clavicle at our hospital were recruited for our study and followup data was collected from our hospital records till their last outpatient visit. Inclusion criteria included patients with no evidence of radiological union, persistence of pain, cosmetic deformity, dysfunction or gross movement at the fracture site even after 16 weeks of conservative treatment or in cases of primary fixation failure. STATISTICAL ANALYSIS All Statistical analyses were made using Statistical Package Software for Social Sciences (SPSS version 17.0 software (Chicago, IL, USA for descriptive data. Chi2 test was used to compare the categorical data. RESULTS At the end of an average followup of 19 months, the average Visual Analogue Score for pain was 1.9±2.2 (range 0-6, the mean ASES score was 81±18.5 (51-100, and the mean Constant–Murley score was 80±17 (51-100. All the patients had a stable radiological union at the end of the followup period. There were no complications pertaining to the hardware or infection. CONCLUSION Treatment of nonunion of clavicle by using corticocancellous bone is well documented; however, use of iliac corticocancellous bone graft shaped in long slivers will give mechanical stability to the plate reconstruct in addition to providing a scaffold for new bone formation than

  13. Double-plating of ovine critical sized defects of the tibia: a low morbidity model enabling continuous in vivo monitoring of bone healing

    Directory of Open Access Journals (Sweden)

    Pearce Alexandra

    2011-09-01

    Full Text Available Abstract Background Recent studies using sheep critical sized defect models to test tissue engineered products report high morbidity and complications rates. This study evaluates a large bone defect model in the sheep tibia, stabilized with two, a novel Carbon fibre Poly-ether-ether-ketone (CF-PEEK and a locking compression plate (LCP which could sustain duration for up to 6 month with an acceptable low complication rate. Methods A large bone defect of 3 cm was performed in the mid diaphysis of the right tibia in 33 sheep. The defect was stabilised with the CF - PEEK plate and an LCP. All sheep were supported with slings for 8 weeks after surgery. The study was carried out for 3 months in 6 and for 6 months in 27 animals. Results The surgical procedure could easily be performed in all sheep and continuous in vivo radiographic evaluation of the defect was possible. This long bone critical sized defect model shows with 6.1% a low rate of complications compared with numbers mentioned in the literature. Conclusions This experimental animal model could serve as a standard model in comparative research. A well defined standard model would reduce the number of experimental animals needed in future studies and would therefore add to ethical considerations.

  14. A new, low cost, locking plate for the long-term fixation of a critical size bone defect in the ratfemur: in vivo performance, biomechanical and finite element analysis.

    Science.gov (United States)

    Mataliotakis, George I; Tsouknidas, Alexander; Panteliou, Sofia; Vekris, Marios D; Mitsionis, Grigorios I; Agathopoulos, Simeon; Beris, Alexander E

    2015-01-01

    The optimum fixation device for the critical size bone defect is not established yet. A reliable, feasible and low-cost fixation device for the long-term maintenance of a critical bone defect. A custom-made plate made of poly-methyl-methacrylate was used for the fixation of a critical defect of rats' femurs. The screws were securely fixing both on the plate and the bone. A three point bending test, aimed to resemble the in vivo loading pattern, a Finite Element Analysis and a 24-week in vivo monitoring of the integrity of the plate fixation were utilized. The plate has linear and reproducible behavior. It presents no discontinuities in the stress field of the fixation. Its properties are attributed to the material and the locking principle. It fails beyond the level of magnitude of the normal ambulatory loads. In vivo, 100% of the plates maintained the bone defect intact up to 12 weeks and 85% of them at 24 weeks. This novel locking plate shows optimal biomechanical performance and reliability with high long-term in vivo survival rate. It is fully implantable, inexpensive and easily manufactured. It can be qualified for long term critical defect fixation in bone regeneration studies.

  15. Cranioplasty using presurgically fabricated presterilised polymethyl methacrylate plate by a simple, cost-effective technique on patients with and without original bone flap: study on 29 patients.

    Science.gov (United States)

    Sharavanan, G M; Jayabalan, Suresh; Rajasukumaran, K; Veerasekar, Ganesh; Sathya, G

    2015-06-01

    The purpose of the study was to assess the clinical effectiveness of presurgically fabricated pre-sterilized polymethyl methacrylate (PMMA) plate as a cranioplasty material. The study group consisted of 29 patients with skull defect following decompressive craniectomy. Some patients had their original bone flap preserved and some were without it. In either group pre-sterilized prefabricated PMMA plate was used. On each visit, patients were clinically assessed; CT scans were taken in immediate follow up period but if needed more films were taken in subsequent follow ups. Post-op complications that include infection, post-op hematoma, chronic pain, aesthetic, biocompatibility, post-op dimensional changes of prosthesis were evaluated. Mean follow up was 7 1/2 months. Five patients developed swelling and pain in the subsequent follow ups. One patient was treated conservatively with antibiotics. Tapping was performed in couple of patients. Surgical evacuation of hematoma was performed in one patient. Of the five infected plates, one demanded removal from the patient. One complained of chronic pain. Post-op follow up assessed clinically and by CT scan confirmed good aesthetic result, biocompatibility and dimensional stability of prosthesis. The result of this study support the view that the use of prefabricated pre-sterilized PMMA plate as cranioplasty material is a simple, reliable, convenient way that brings acceptable function and aesthetics to patients who underwent decompressive craniectomy, in an inexpensive way.

  16. Ex vivo torsional properties of a 2.5 mm veterinary interlocking nail system in canine femurs. Comparison with a 2.4 mm limited contact bone plate.

    Science.gov (United States)

    Macedo, Aline S; Moens, Noel M M; Runciman, John; Gibson, Tom W G; Minto, Bruno W

    2017-03-20

    To evaluate the torsional properties of the Targon ® Vet Nail System (TVS) in small canine femurs and to compare these properties to those of the 2.4 mm LC-DCP ® plates. Thirty-six cadaveric femurs were allocated to three groups (n = 12). In all bones, points just distal to the lesser trochanter and just proximal to the fabellae were marked and a midshaft transverse osteotomy was performed. Group 1: bones were fixed with the 2.5 mm TVS with the bolts applied at the pre-identified marks. Group 2: A TVS system with 25% shorter inter-bolt distance was used. Group 3: A 7-hole 2.4 mm LC-DCP ® plates were applied. All constructs were tested non-destructively for 10 cycles, followed by an acute torsion to failure. Torque at yield was 0.806 ± 0.183 and 0.805 ± 0.093 Nm for groups 1 and 2 and 1.737 ± 0.461 Nm for group 3. Stiffness was 0.05 ± 0.01, 0.05 ± 0.007, and 0.14 ± 0.015 Nm/° for groups 1 to 3 respectively. Maximal angular displacement under cyclic loading was 16.6° ± 2.5°, 15.6° ± 2.1°, and 7.8° ± 1.06° respectively. There was no significant difference for any of the parameters between groups 1 and 2. Both torque at yield and stiffness were significantly greater between group 3 and groups 1 and 2. The TVS had approximately half the torsional strength and approximately 1/3 of the stiffness of the 2.4 mm bone plate. Slippage of the locking mechanism was probably the cause of the early failure. The system should be considered as a low-strength and low-stiffness system when compared to bone plates.

  17. Bone-preserving prosthesis with a single axis for treating osteonecrosis of the femoral head: midterm results for the thrust plate hip prosthesis.

    Science.gov (United States)

    Yasunaga, Yuji; Goto, Toshihiko; Hisatome, Takashi; Tanaka, Ryuji; Yamasaki, Takuma; Ochi, Mitsuo

    2003-01-01

    We studied 27 patients (31 joints) who underwent total hip arthroplasty (THA) using the thrust plate hip prosthesis (TPP) for osteonecrosis of the femoral head. The mean follow-up period was 56 months (range 38-72 months). Clinical evaluation by the Merle d'Aubigne and Postel system showed a significant improvement from a preoperative mean score of 8.1 to a final mean follow-up score of 16.6. Mechanical loosening developed about 1 year postoperatively in one joint with a bone defect. Grade 1 stress shielding was observed in four joints. Although indications for the TPP are restricted to certain cases, unlike the conventional intramedullary stem, much can be expected of TPP. It is an outstanding prosthesis for osteonecrosis of the femoral head of young patients in terms of bone preservation and physiological load transfer.

  18. Effect of nicotine and preventive role of camellia sinensis on the histomorphology of developing epiphyseal plate of thigh bone of chick

    International Nuclear Information System (INIS)

    Shan, M.; Butt, S.A.

    2014-01-01

    Objective: To determine the effect of nicotine and camellia sinensis (green tea) on the developing epiphyseal plate of thigh bone of chick. Design: Randomized controlled trial. Place and Duration of Study: Army medical college, Rawalpindi, Pakistan from April 2012 to May 2012. Material and Method: Freshly laid fertilized eggs of Fayoumi breed chick eggs were selected at zero hour of incubation. Four groups were made, group G1 was control group treated with normal saline. Experimental group G2 was treated with camellia sinensis extract (green tea), group G3 was given nicotine whereas group G4 was injected with working solution nicotine and camellia sinensis (green tea), in 0.1 ml quantity. Double exposure one at 48 hour of incubation and other at 48 hours after hatching of chicks. SPSS version 15 was used to analyze the data. Results: It was observed that the weight of chick at one month of age and weight of femur of chicks of nicotine treated groups G3 and group G4 were reduced in comparison to control group G1. Mean number of cells in hypertrophy zone of developing epiphyseal plate of thigh bone were reduced of nicotine treated groups in comparison to control group. Conclusion: Camellia sinensis (green tea) helped to reduce the harmful effects of nicotine treated group but cannot reverse the oxidative injury. (author)

  19. Histomorphometric Parameters of the Growth Plate and Trabecular Bone in Wild-Type and Trefoil Factor Family 3 (Tff3)-Deficient Mice Analyzed by Free and Open-Source Image Processing Software.

    Science.gov (United States)

    Bijelić, Nikola; Belovari, Tatjana; Stolnik, Dunja; Lovrić, Ivana; Baus Lončar, Mirela

    2017-08-01

    Trefoil factor family 3 (Tff3) peptide is present during intrauterine endochondral ossification in mice, and its deficiency affects cancellous bone quality in secondary ossification centers of mouse tibiae. The aim of this study was to quantitatively analyze parameters describing the growth plate and primary ossification centers in tibiae of 1-month-old wild-type and Tff3 knock-out mice (n=5 per genotype) by using free and open-source software. Digital photographs of the growth plates and trabecular bone were processed by open-source computer programs GIMP and FIJI. Histomorphometric parameters were calculated using measurements made with FIJI. Tff3 knock-out mice had significantly smaller trabecular number and significantly larger trabecular separation. Trabecular bone volume, trabecular bone surface, and trabecular thickness showed no significant difference between the two groups. Although such histomorphological differences were found in the cancellous bone structure, no significant differences were found in the epiphyseal plate histomorphology. Tff3 peptide probably has an effect on the formation and quality of the cancellous bone in the primary ossification centers, but not through disrupting the epiphyseal plate morphology. This work emphasizes the benefits of using free and open-source programs for morphological studies in life sciences.

  20. Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects

    Directory of Open Access Journals (Sweden)

    Roghieh Bardal Bardal

    2016-08-01

    Full Text Available Objectives: The optimal goal of radiography is to provide high-quality diagnostic images with the least patient radiation dose. The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT and intraoral photostimulable phosphor plate (PSP digital and film-based conventional radiography for detection of artificial cancellous bone defects.Materials and Methods: Five dry human mandibles were used in this study. The mandibles were placed inside a water bath made of plexiglass plates; then PSP and CBCT scans were obtained. The mandibles were cut by a coping saw in buccolingual dimension and oval defects measuring 6.1×6.1 mm, 3×6.1 mm and 4×4 mm were created by a milling machine in the spongy bone. After fixing the two parts together (buccal and lingual, radiographs were repeated. Presence or absence of defects on images was evaluated and recorded by the two observers. Using SPSS 16, compatibility level, sensitivity, specificity and receiver operating curve (ROC analysis were determined for each observer.Results: The intraobserver agreement in all three imaging modalities was low to moderate (kappa≤0.613. The inter-observer agreement in all the three imaging modalities was moderate (kappa=0.406. The area under the curve (AUC of the imaging modalities in each observation was not significantly different. The area under the curve based on defect size for the two observers was not significantly different either.Conclusion: Defects confined to spongy bone can be identified on film and PSP radiographs and CBCT scans. However, interpretation of PSP images and CBCT scans needs greater expertise and skills.

  1. Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects.

    Science.gov (United States)

    Bardal, Roghieh; Jahanihashemi, Hassan; Mostafavi, Maryam; Kalhor, Esmaeil; Tofangchiha, Maryam; Dehghani, Mahdieh

    2015-11-01

    The optimal goal of radiography is to provide high-quality diagnostic images with the least patient radiation dose. The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT) and intraoral photostimulable phosphor plate (PSP) digital and film-based conventional radiography for detection of artificial cancellous bone defects. Five dry human mandibles were used in this study. The mandibles were placed inside a water bath made of plexiglass plates; then PSP and CBCT scans were obtained. The mandibles were cut by a coping saw in buccolingual dimension and oval defects measuring 6.1×6.1 mm, 3×6.1 mm and 4×4 mm were created by a milling machine in the spongy bone. After fixing the two parts together (buccal and lingual), radiographs were repeated. Presence or absence of defects on images was evaluated and recorded by the two observers. Using SPSS 16, compatibility level, sensitivity, specificity and receiver operating curve (ROC) analysis were determined for each observer. The intraobserver agreement in all three imaging modalities was low to moderate (kappa≤0.613). The inter-observer agreement in all the three imaging modalities was moderate (kappa=0.406). The area under the curve (AUC) of the imaging modalities in each observation was not significantly different. The area under the curve based on defect size for the two observers was not significantly different either. Defects confined to spongy bone can be identified on film and PSP radiographs and CBCT scans. However, interpretation of PSP images and CBCT scans needs greater expertise and skills.

  2. Correção de falhas ósseas diafisárias: trasnporte ósseo fixado com placa Corretive procedure in diaphyseal bone gaps: bone trasnpot fixated with plate

    Directory of Open Access Journals (Sweden)

    Celso Hermínio Ferraz Picado

    2007-01-01

    Full Text Available O objetivo deste estudo é descrever um novo sistema de transporte ósseo que dispensa o uso de fios transfixantes. O sistema, constituído por uma placa, um carro móvel e por um dispositivo tracionador, foi instalado na tíbia direita de 17 ovelhas para preencher um defeito ósseo de 1 cm. O transporte ósseo foi iniciado 7 dias após a cirurgia numa taxa de 0,8 mm/dia, dividido em 0,2 mm a cada 6 horas. Radiografias em ântero-posterior e perfil foram realizadas imediatamente após a cirurgia e semanalmente até o término do transporte. Em todos os 12 animais que completaram o estudo, o defeito ósseo foi preenchido com formação do regenerado e consolidação do foco alvo. O estudo demonstra que o sistema aqui apresentado realiza o transporte ósseo de maneira efetiva, eliminando o uso de fios ou pinos transfixantes.The objective of this study is to describe a new bone transport system not requiring the use of transfixating wires. The system, which is constituted by a plate, a movable conveyor and a hauling device, was set up on the right tibia of 17 sheep intending to fill a 1-cm bone gap. Bone transport started 7 days after surgery on a rate of 0.8 mm/day, divided into 0.2 mm at each 6 hours. X-ray images of anteroposterior and lateral planes were taken immediately after surgery and on a weekly basis until transport was finished. In all 12 animals completing the study, the bone gap was filled with regenerated formation and target focus consolidation. The study shows that the system presented here effectively performs bone transport, eliminating the use of transfixating wires or pins.

  3. Growth Plate Injuries

    Science.gov (United States)

    ... cause any lasting problems for your child or teen. Growth plates are areas of growing tissues that cause ... are replaced by solid bone. Who gets them? Growth plate injuries happen to children and teens. This injury happens twice as often in boys ...

  4. Orthogonal Double Plating and Autologous Bone Grafting of Postoperative Humeral Shaft Nonunion ? A Rare Case Report and Review of Literature

    OpenAIRE

    Metikala, Sreenivasulu; Bhogadi, Prabhudheer

    2015-01-01

    Introduction: Nonunion following surgical stabilization of humeral shaft fractures, although infrequent, remains a challenge as limited surgical options are available. The difficulties in re-fixation are due to osteolysis produced by the loose implant components and disuse osteopenia of the entire bone segment. We share our experience in the management of a long standing diaphyseal nonunion of humerus following titanium LCP fixation. Case Report: A 58 years old woman presented with 20 months ...

  5. Ipsilateral Femoral Fracture Non-Union and Delayed Union Treated By Hybrid Plate Nail Fixation and Vascularized Fibula Bone Grafting: A Case Report

    Directory of Open Access Journals (Sweden)

    CK Chan

    2013-07-01

    Full Text Available Non-union is a well recognized complication of femoral neck fractures. The decision whether to attempt fracture fixation or to resort to hip replacement is particularly difficult in patients in the borderline age group in whom complex attempts at gaining union may fail and later present a difficult revision. On the other hand the patient may be young enough that arthroplasty best be avoided . Besides, presence of ipsilateral femoral shaft fracture with delayed union in addition to the femoral neck non-union will pose major problems at operation. We share our experience in treating a femoral neck fracture non-union with ipsilateral femoral shaft delayed union in the shaft and in the distal femur in a fifty years old patient. The fracture was treated with an angle blade plate and supracondylar nail supplemented with a free vascularised fibular bone grafting and autologous cancellous graft. There was radiological union at fourth month. At sixth months, the patient was free of pain and able to walk without support. Thus, we would like to suggest that vascularised fibula bone grafting with supracondylar nailing is a viable option for this pattern of fracture.

  6. Lateral expansion of the rat lower dental arch by applying an active plate model to the mandibular first molar region: observation of histological changes in the lower alveolar bone over a 2-week period.

    Science.gov (United States)

    Ogihara, Eiwa; Ogihara, Kazuhiko; Aiyama, Shigeo

    2004-03-01

    Lateral expansion of the lower dental arch has rarely been conducted clinically because the structure of the lower jaw is considered to be unsuitable for this type of treatment. However, successful lateral expansion of the lower dental arch using SCHWALZ, an orthopedic appliance has been reported in recent years. Therefore, an experimental study was performed to examine the histological changes in the lower alveolar bone when lateral expansion is applied to the lower dental arch for periods of up to 2 weeks. An active plate model based on the Schwarz appliance was attached to the first molar region in rats. The distance between the right and left first molars was measured, and the mandible and first molar tooth were processed for light microscopy at different times after the fitting. The lateral expansion caused by lateral movement of the right and left first molars following the application of the active plate amounted to an average of 1.06 mm over a period of 14 days. Alkaline phosphatase/tartrate-resistant acid phosphatase staining revealed bone deposition on the periosteal surface of the buccal alveolar bone and the periodontal surface of the lingual alveolar bone, whereas bone absorption was observed on the periodontal surface of the buccal alveolar bone and the periosteal surface of the lingual alveolar bone. These findings demonstrate that lateral expansion of the lower dental arch through the application of an active plate model was achieved by bony deposition and absorption of alveolar bone, similar to the process that occurs in association with lateral expansion of the upper dental arch.

  7. Safety and feasibility of cell-based therapy of autologous bone marrow-derived mononuclear cells in plate-stabilized proximal humeral fractures in humans

    Directory of Open Access Journals (Sweden)

    Caroline Seebach

    2016-11-01

    Full Text Available Abstract Background Local implantation of ex vivo concentrated, washed and filtrated human bone marrow-derived mononuclear cells (BMC seeded onto β-tricalciumphosphate (TCP significantly enhanced bone healing in a preclinical segmental defect model. Based on these results, we evaluated in a first clinical phase-I trial safety and feasibility of augmentation with preoperatively isolated autologous BMC seeded onto β-TCP in combination with angle stable plate fixation for the therapy of proximal humeral fractures as a potential alternative to autologous bone graft from the iliac crest. Methods 10 patients were enrolled to assess whether cell therapy with 1.3 × 106 autologous BMC/ml/ml β-TCP, collected on the day preceding the definitive surgery, is safe and feasible when seeded onto β-TCP in patients with a proximal humeral fracture. 5 follow-up visits for clinical and radiological controls up to 12 weeks were performed. Results β-tricalciumphosphate fortification with BMC was feasible and safe; specifically, neither morbidity at the harvest site nor at the surgical wound site were observed. Neither local nor systemic inflammation was noted. All fractures healed within the observation time without secondary dislocation. Three adverse events were reported: one case each of abdominal wall shingles, tendon loosening and initial screw perforation, none of which presumed related to the IND. Conclusions Cell therapy with autologous BMC for bone regeneration appeared to be safe and feasible with no drug-related adverse reactions being described to date. The impression of efficacy was given, although the study was not powered nor controlled to detect such. A clinical trial phase-II will be forthcoming in order to formally test the clinical benefit of BMC-laden β-TCP for PHF patients. Trial registration The study was registered in the European Clinical Trial Register as EudraCT No. 2012-004037-17. Date of registration 30th of August 2012. Informed

  8. Influence of screw holes and gamma sterilization on properties of phosphate glass fiber-reinforced composite bone plates.

    Science.gov (United States)

    Han, Na; Ahmed, Ifty; Parsons, Andrew J; Harper, Lee; Scotchford, Colin A; Scammell, Brigitte E; Rudd, Chris D

    2013-05-01

    Polymers prepared from polylactic acid (PLA) have found a multitude of uses as medical devices. For a material that degrades, the main advantage is that an implant would not necessitate a second surgical event for removal. In this study, fibers produced from a quaternary phosphate-based glass (PBG) in the system 50P2O5-40CaO-5Na2O-5Fe2O3 were used to reinforce PLA polymer. The purpose of this study was to assess the effect of screw holes in a range of PBG-reinforced PLA composites with varying fiber layup and volume fraction. The flexural properties obtained showed that the strength and modulus values increased with increasing fiber volume fraction; from 96 MPa to 320 MPa for strength and between 4 GPa and 24 GPa for modulus. Furthermore, utilizing a larger number of thinner unidirectional (UD) fiber prepreg layers provided a significant increase in mechanical properties, which was attributed to enhanced wet out and thus better fiber dispersion during production. The effect of gamma sterilization via flexural tests showed no statistically significant difference between the sterilized and nonsterilized samples, with the exception of the modulus values for samples with screw holes. Degradation profiles revealed that samples with screw holes degraded faster than those without screw holes due to an increased surface area for the plates with screw holes in PBS up to 30 days. Scanning electron microscope (SEM) analysis revealed fiber pullout before and after degradation. Compared with various fiber impregnation samples, with 25% volume fraction, 8 thinner unidirectional prepreg stacked samples had the shortest fiber pull-out lengths in comparison to the other samples investigated.

  9. Dynamic compression plate (DCP) fixation of propagating medial condylar fractures of the third metacarpal/metatarsal bone in 30 racehorses: retrospective analysis (1990-2005).

    Science.gov (United States)

    Goodrich, L R; Nixon, A J; Conway, J D; Morley, P S; Bladon, B M; Hogan, P M

    2014-11-01

    An in-depth review of dynamic compression plate (DCP) fixation of propagating medial condyle fractures of the third metacarpus or metatarsus has not been previously reported. To describe the technique, evaluate short-term outcome and long-term race performance of racehorses that underwent DCP fixation for repair of propagating or spiralling medial condylar fractures of the third metacarpal (McIII) or metatarsal (MtIII) bone. Retrospective case series. The surgical case records of 30 horses with propagating fractures of the medial condyle of McIII or MtIII were reviewed. Medical information included: age, breed, sex, presentation, how injury occurred (racing or training), surgical treatment and post operative complications. Racing information included: starts, top 3 placing and career earnings. Long propagating fractures of the medial condyle of Mc/tIII were identified in 23 Thoroughbred (TB) and 7 Standardbred (STB) racehorses. The fracture spiralled proximally in 22 of 30 cases (73%). Standardbreds had a higher propensity for hindlimb involvement (71%), whereas TBs tended to have more front limb involvement (61%). Twelve of 30 (40%) horses raced post surgery. Career earnings were significantly lower for TB horses with medial condylar fractures; $34,916 when compared with the national average of $60,841 (P≤0.03). Overall, horses having DCP fixation for medial condylar fractures had less starts post surgery (3.1 TBs and 5.8 STBs) compared with the national average (7 TBs and 17.3 STBs) and decreased lifetime starts 13.4 (TBs) compared with 17.3 nationally. Propagating medial condyle fractures can be repaired with plate fixation to potentially lessen the risk of catastrophic fracture destabilisation and return to racing can be expected in 40% of horses. Further prospective studies are warranted comparing lag screw fixation with DCP fixation for repair of severe medial condylar fractures of the metacarpus/metatarsus. © 2013 The Authors. Equine Veterinary Journal

  10. A Dual Role of Upper Zone of Growth Plate and Cartilage Matrix-Associated Protein in Human and Mouse Osteoarthritic Cartilage: Inhibition of Aggrecanases and Promotion of Bone Turnover.

    Science.gov (United States)

    Stock, Michael; Menges, Stefanie; Eitzinger, Nicole; Geßlein, Maria; Botschner, Renate; Wormser, Laura; Distler, Alfiya; Schlötzer-Schrehardt, Ursula; Dietel, Katharina; Distler, Jörg; Beyer, Christian; Gelse, Kolja; Engelke, Klaus; Koenders, Marije I; van den Berg, Wim; von der Mark, Klaus; Schett, Georg

    2017-06-01

    Cartilage damage and subchondral bone changes are closely connected in osteoarthritis. Nevertheless, how these processes are interlinked is, to date, incompletely understood. This study was undertaken to investigate the mechanistic role of a cartilage-derived protein, upper zone of growth plate and cartilage matrix-associated protein (UCMA), in osteoarthritis-related cartilage and bone changes. UCMA expression was assessed in healthy and osteoarthritic human and mouse cartilage. For analysis of cartilage and bone changes, osteoarthritis was induced by destabilization of the medial meniscus (DMM) in wild-type (WT) and Ucma-deficient mice. UCMA-collagen interactions, the effect of UCMA on aggrecanase activity, and the impact of recombinant UCMA on osteoclast differentiation were studied in vitro. UCMA was found to be overexpressed in human and mouse osteoarthritic cartilage. DMM-triggered cartilage changes, including increased structural damage, proteoglycan loss, and chondrocyte cell death, were aggravated in Ucma-deficient mice compared to WT littermates, thereby demonstrating the potential chondroprotective effects of UCMA. Moreover, UCMA inhibited ADAMTS-dependent aggrecanase activity and directly interacted with cartilage-specific collagen types. In contrast, osteoarthritis-related bone changes were significantly reduced in Ucma-deficient mice, showing less pronounced osteophyte formation and subchondral bone sclerosis. Mechanistically, UCMA directly promoted osteoclast differentiation in vitro. UCMA appears to link cartilage with bone changes in osteoarthritis by supporting cartilage integrity as an endogenous inhibitor of aggrecanases while also promoting osteoclastogenesis and subchondral bone turnover. Thus, UCMA represents an important link between cartilage and bone in osteoarthritis. © 2017, American College of Rheumatology.

  11. Open reduction and cranial bone plate fixation of fractures involving the distal aspect of the radius and ulna in miniature- and toy-breed dogs: 102 cases (2008-2015).

    Science.gov (United States)

    De Arburn Parent, Rebecca; Benamou, Jérôme; Gatineau, Matthieu; Clerfond, Pierre; Planté, Jérôme

    2017-06-15

    OBJECTIVE To determine outcomes and complication rates of open reduction and cranial bone plate fixation of fractures involving the distal aspect of the radius and ulna in miniature- and toy-breed dogs. DESIGN Retrospective case series. ANIMALS 102 miniature- and toy-breed dogs (105 fractures) weighing ≤ 7 kg (15.4 lb) that had undergone open reduction and cranial bone plate fixation of a fracture involving the distal aspect of the radius and ulna from 2008 through 2015. PROCEDURES Medical records were reviewed and information extracted regarding dog and fracture characteristics, surgical variables, and follow-up examination data (including postoperative complications). Postoperative radiographs were examined for distal fragment size, implant placement, apposition, alignment, and healing stage. A long-term follow-up questionnaire was completed by telephone interview with dog owners at least 6 months after surgery. RESULTS Mean length of the distal bone fragment in all fractures was 19.2 mm, with a mean distal-to-total radial length ratio of 0.21. At last follow-up examination (typically 6 weeks after surgery), 97 (95%) dogs had no signs of lameness; minor lameness was identified in 5 (5%) dogs. Complications developed in 26 (25%) fractures (23 [22%] minor and 3 [3%] major complications). Sixty-eight of 71 (96%) owners rated the overall and long-term outcome as excellent and 3 (4%) as good; 68 of 71 (96%) dogs reportedly had no signs of residual lameness. CONCLUSIONS AND CLINICAL RELEVANCE Open reduction and cranial bone plate fixation for the treatment of radius-ulna fractures in miniature- and toy-breed dogs provided an excellent outcome with a low complication rate.

  12. An in vitro biomechanical comparison of hydroxyapatite coated and uncoated ao cortical bone screws for a limited contact: dynamic compression plate fixation of osteotomized equine 3rd metacarpal bones.

    Science.gov (United States)

    Durham, Myra E; Sod, Gary A; Riggs, Laura M; Mitchell, Colin F

    2015-02-01

    To compare the monotonic biomechanical properties of a broad 4.5 mm limited contact-dynamic compression plate (LC-DCP) fixation secured with hydroxyapatite (HA) coated cortical bone screws (HA-LC-DCP) versus uncoated cortical bone screws (AO-LC-DCP) to repair osteotomized equine 3rd metacarpal (MC3) bones. Experimental. Adult equine cadaveric MC3 bones (n = 12 pair). Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for: (1) 4 point bending single cycle to failure testing; (2) 4 point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. For the HA-LC-DCP-MC3 construct, an 8-hole broad LC-DCP (Synthes Ltd, Paoli, PA) was secured on the dorsal surface of each randomly selected MC3 bone with a combination of four 5.5 mm and four 4.5 mm HA-coated cortical screws. For the AO-LC-DCP-MC3 construct, an 8-hole 4.5 mm broad LC-DCP was secured on the dorsal surface of the contralateral MC3 bone with a combination of four 5.5 mm and four 4.5 mm uncoated cortical screws. All MC3 bones had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P < .05. Mean yield load, yield bending moment, composite rigidity, failure load, and failure bending moment, under 4 point bending, single cycle to failure, of the HA-LC-DCP fixation were significantly greater than those of the AO-LC-DCP fixation. Mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, in single cycle to failure under 4 point bending were: yield load, 26.7 ± 2.15 and 16.3 ± 1.38 kN; yield bending moment, 527.4 ± 42.4 and 322.9 ± 27.2 N-m; composite rigidity, 5306 ± 399 and 3003 ± 300 N-m/rad; failure load, 40.6 ± 3.94 and 26.5 ± 2.52 kN; and failure bending moment, 801.9 ± 77.9 and 522.9 ± 52.2 N-m. Mean cycles to failure in 4 point bending of the HA

  13. A biomechanical comparison of proximal femoral nails and locking proximal anatomic femoral plates in femoral fracture fixation A study on synthetic bones

    Directory of Open Access Journals (Sweden)

    Korhan Ozkan

    2015-01-01

    Conclusion: The proximal femoral intramedullary nail provides more stability and allows for earlier weight bearing than the locking plate when used for the treatment of unstable intertrochanteric fractures of the femur. Clinicians should be cautious for early weight bearing with locking plate for unstable intertrochanteric femur fractures.

  14. Cold plate

    Energy Technology Data Exchange (ETDEWEB)

    Marroquin, Christopher M.; O' Connell, Kevin M.; Schultz, Mark D.; Tian, Shurong

    2018-02-13

    A cold plate, an electronic assembly including a cold plate, and a method for forming a cold plate are provided. The cold plate includes an interface plate and an opposing plate that form a plenum. The cold plate includes a plurality of active areas arranged for alignment over respective heat generating portions of an electronic assembly, and non-active areas between the active areas. A cooling fluid flows through the plenum. The plenum, at the non-active areas, has a reduced width and/or reduced height relative to the plenum at the active areas. The reduced width and/or height of the plenum, and exterior dimensions of cold plate, at the non-active areas allow the non-active areas to flex to accommodate surface variations of the electronics assembly. The reduced width and/or height non-active areas can be specifically shaped to fit between physical features of the electronics assembly.

  15. Mecânica e microbiologia de placas produzidas a partir de osso cortical bovino, conservadas em diferentes meios Mechanic and microbiology of plates produced from bovine cortical bone, conserved in several means

    Directory of Open Access Journals (Sweden)

    Edson Vilela de Melo Filho

    2011-04-01

    Full Text Available Objetivou-se com este trabalho avaliar a resistência mecânica de placas ósseas produzidas a partir de osso cortical bovino, conservadas em diferentes meios, e a eficiência desses meios em inibir o crescimento de microrganismos. Foram utilizadas 168 placas confeccionadas a partir de tíbia bovina e conservadas em glicerina a 98%, solução salina a 150%, solução de açúcar a 300%, líquido de Dakin, congeladas em N2L a -196°C, ou esterilizadas em óxido de etileno. Após reidratação em solução de cloreto de sódio a 0,9% por seis horas, elas foram submetidas a ensaios mecânicos de tração, compressão, flexão e torção. Foi realizada avaliação microbiológica das placas anterior e imediatamente após a reidratação, com ou sem adição de enrofloxacina a 0,5%. Não se observou diferença significativa (PThe objective of this study was to evaluate the mechanical strength of bone plates yielded from bovine cortical bone, conserved in different solutions, and the efficiency of these solutions in the inhibition of microorganism's growth. A hundred and sixty eight plates yielded from bovine tibiae were conserved in 98% glycerin, 150% saline solution, 300% sugar solution, Dakin solution, frozen in N2L at - 196°C, or sterilized in ethylene oxide gas. After rehydration in NaCl 0.9% solution for six hours, plates were subjected to tensile, compression, bending and twisting testing. The microbiological evaluation of bone plates was s carried out before and immediately after rehydration, with or without enrofloxacin 0.5% addition. There was no significant difference (P<0.01% on resistance to the rupture point in plates conserved in different solutions, frozen-thawed or sterilized. Microorganisms were isolated from plates conserved in satured salt solution, sugar satured solution, Dakin solution or frozen in N2L, before and after rehydraion However, after the use of NaCl 0.9% solution added of enrofloxacin 0.5%, microorganisms were not

  16. Plating laboratory

    International Nuclear Information System (INIS)

    Seamster, A.G.; Weitkamp, W.G.

    1984-01-01

    The lead plating of the prototype resonator has been conducted entirely in the plating laboratory at SUNY Stony Brook. Because of the considerable cost and inconvenience in transporting personnel and materials to and from Stony Brook, it is clearly impractical to plate all the resonators there. Furthermore, the high-beta resonator cannot be accommodated at Stony Brook without modifying the set up there. Consequently the authors are constructing a plating lab in-house

  17. Histomorphometric study of diazinon on growth plate of rat

    Directory of Open Access Journals (Sweden)

    Mahdiye Bazmi

    2015-07-01

    Conclusion: Diazinon leads to reduction in the Epiphyseal growth plate width of immature male rats. Therefore it could be a factor in the impairment of bone longitudinal growth and premature closure of the growth plate.

  18. The effect of permanent grafting materials on the preservation of the buccal bone plate after tooth extraction: an experimental study in the dog.

    LENUS (Irish Health Repository)

    Bashara, Haitham

    2012-08-01

    The aim of the present study was to evaluate the effects of a novel bone substitute system (Natix(®)), consisting of porous titanium granules (PTG) and a bovine-derived xenograft (Bio-Oss(®)), on hard tissue remodelling following their placement into fresh extraction sockets in dogs.

  19. Linear signal hyperintensity adjacent to the subchondral bone plate at the knee on T2-weighted fat-saturated sequences: imaging aspects and association with structural lesions

    International Nuclear Information System (INIS)

    Gondim Teixeira, Pedro Augusto; Balaj, Clemence; Marie, Beatrice; Lecocq, Sophie; Louis, Matthias; Blum, Alain; Braun, Marc

    2014-01-01

    To describe the association between linear T2 signal abnormalities in the subchondral bone and structural knee lesions. MR studies of patients referred for the evaluation of knee pain were retrospectively evaluated and 133 of these patients presented bone marrow edema pattern (BMEP) (study group) and while 61 did not (control group). The presence of linear anomalies of the subchondral bone on T2-weighted fat-saturated sequences was evaluated. The findings were correlated to the presence of structural knee lesions and to the duration of the patient's symptoms. Histologic analysis of a cadaveric specimen was used for anatomic correlation. Linear T2 hyperintensities at the subchondral bone were present in 41 % of patients with BMEP. None of the patients in the control group presented this sign. When a subchondral linear hyperintensity was present, the prevalence of radial or root tears was high and that of horizontal tears was low (71.4 and 4.8 %, respectively). Sixty-nine percent of the patients with a subchondral insufficiency fracture presented a subchondral linear hyperintensity. It was significantly more prevalent in patients with acute or sub-acute symptoms (p < 0.0001). The studied linear T2 hyperintensity is located at the subchondral spongiosa and can be secondary to local or distant joint injuries. Its presence should evoke acute and sub-acute knee injuries. This sign is closely related to subchondral insufficiency fractures and meniscal tears with a compromise in meniscal function. (orig.)

  20. Linear signal hyperintensity adjacent to the subchondral bone plate at the knee on T2-weighted fat-saturated sequences: imaging aspects and association with structural lesions

    Energy Technology Data Exchange (ETDEWEB)

    Gondim Teixeira, Pedro Augusto; Balaj, Clemence [CHU Hopital Central, Service D' Imagerie Guilloz, Nancy (France); Universite de Lorraine, IADI, UMR S 947, Nancy (France); Marie, Beatrice [CHU Hopital Central, Service d' Anatomo-Pathologie, Nancy (France); Lecocq, Sophie; Louis, Matthias; Blum, Alain [CHU Hopital Central, Service D' Imagerie Guilloz, Nancy (France); Braun, Marc [CHU Hopital Central, Service de Neuroradiologie, Nancy (France)

    2014-11-15

    To describe the association between linear T2 signal abnormalities in the subchondral bone and structural knee lesions. MR studies of patients referred for the evaluation of knee pain were retrospectively evaluated and 133 of these patients presented bone marrow edema pattern (BMEP) (study group) and while 61 did not (control group). The presence of linear anomalies of the subchondral bone on T2-weighted fat-saturated sequences was evaluated. The findings were correlated to the presence of structural knee lesions and to the duration of the patient's symptoms. Histologic analysis of a cadaveric specimen was used for anatomic correlation. Linear T2 hyperintensities at the subchondral bone were present in 41 % of patients with BMEP. None of the patients in the control group presented this sign. When a subchondral linear hyperintensity was present, the prevalence of radial or root tears was high and that of horizontal tears was low (71.4 and 4.8 %, respectively). Sixty-nine percent of the patients with a subchondral insufficiency fracture presented a subchondral linear hyperintensity. It was significantly more prevalent in patients with acute or sub-acute symptoms (p < 0.0001). The studied linear T2 hyperintensity is located at the subchondral spongiosa and can be secondary to local or distant joint injuries. Its presence should evoke acute and sub-acute knee injuries. This sign is closely related to subchondral insufficiency fractures and meniscal tears with a compromise in meniscal function. (orig.)

  1. Is the novel olecranon tension plate a valid alternative to tension band wiring of olecranon fractures? A biomechanical study on cadaver bones.

    Science.gov (United States)

    Gruszka, Dominik; Arand, Charlotte; Greenfield, Julia; Nowak, Tobias E; Kuechle, Raphael; Kuhn, Sebastian; Rommens, Pol M

    2017-12-01

    Tension band wiring (TBW) used for olecranon fractures is afflicted with a high rate of complications. The aim of this study was to compare the stability of the TBW versus an alternative, novel low-profile olecranon tension plate (OTP) with angular stable screws in a simulated complex fracture model. Nine fresh-frozen pairs of cadaver proximal ulnae with an oblique osteotomy and an additional wedge fragment simulating an unstable fracture were tested. The TBW and OTP were implanted pairwise. The elbow motion was simulated in a single-muscle model and ranged from full extension to 90° of flexion. The pulling force of the triceps tendon ranged from 50 to 200 N. The displacement of the fracture fragments was measured with a video motion analysis system over 304 cycles. Data were assessed statistically using the Wilcoxon signed-rank test. The cyclic loading tests showed mean loosening of the fracture fragments at the articular surface of 0.56 mm using TBW (SD 0.65) and 0.15 mm for OTP (SD 0.39). There was no statistical significance in loosening between the two constructs (p = 0.31). No plate breakage or screw loosening occurred. The low-profile OTP, using the principles of pre-tensioning, lag, cortical, and angular stable screws together, demonstrated similar stability after olecranon fracture fixation when compared with the TBW technique and a lag screw in the olecranon fracture model with a third wedge fragment.

  2. Biomechanical analysis of titanium fixation plates and screws in ...

    African Journals Online (AJOL)

    Conclusions: It was concluded that the use of double 4-hole straight plates provided the sufficient stability on the osteotomy site when compared with the other rigid fixation methods used in this study. Key words: Bone plates, bone screws, finite element analysis, jaw fixation techniques, mandible, mandibular osteotomy ...

  3. Bone tumor

    Science.gov (United States)

    Tumor - bone; Bone cancer; Primary bone tumor; Secondary bone tumor; Bone tumor - benign ... The cause of bone tumors is unknown. They often occur in areas of the bone that grow rapidly. Possible causes include: Genetic defects ...

  4. Single cycle to failure in bending of three standard and five locking plates and plate constructs.

    Science.gov (United States)

    Blake, C A; Boudrieau, R J; Torrance, B S; Tacvorian, E K; Cabassu, J B; Gaudette, G R; Kowaleski, M P

    2011-01-01

    To evaluate the biomechanical properties of standard and locking plates in bending. We hypothesised that titanium (Ti) constructs would have the greatest deformation and that String of Pearl (SOP) constructs would have the greatest strength and stiffness, and would behave differently compared to plates alone. Dynamic compression plates (DCP), stainless steel (SS) limited contact (LC)-DCP®, Ti LC-DCP, locking compression plates (LCP), 10 mm and 11 mm advanced locking plate system (ALPS 10 / 11), SOP and Fixin plates were evaluated individually and as constructs applied to a validated bone model simulating a bridging osteosynthesis. Bending stiffness and strength were compared using one-way ANOVA with post hoc Tukey, and unpaired t-test (p <0.05). The SOP plates had significantly greater stiffness than all other plates; Ti LC-DCP, ALPS 10 and Fixin plates had significantly lower stiffness than all other plates. The SOP constructs had the highest mean bending stiffness, and strength that was significantly different from only the Ti LC-DCP, ALPS 10 and Fixin constructs. The ALPS 10 constructs had the lowest mean bending stiffness, and strength that was significantly different from only ALPS 11 and SOP constructs. Comparison of bending structural stiffness of plates versus constructs showed a significant difference in all plate pairs except for the DCP and ALPS 10. Due to differing plate construct properties inherent to these diverse implant systems, identical approaches to fracture management and plate application cannot be applied.

  5. History of internal fixation with plates (part 2): new developments after World War II; compressing plates and locked plates.

    Science.gov (United States)

    Hernigou, Philippe; Pariat, Jacques

    2017-07-01

    The first techniques of operative fracture with plates were developed in the 19th century. In fact, at the beginning these methods consisted of an open reduction of the fracture usually followed by a very unstable fixation. As a consequence, the fracture had to be opened with a real risk of (sometimes lethal) infection, and due to unstable fixation, protection with a cast was often necessary. During the period between World Wars I and II, plates for fracture fixation developed with great variety. It became increasingly recognised that, because a fracture of a long bone normally heals with minimal resorption at the bone ends, this may result in slight shortening and collapse, so a very rigid plate might prevent such collapse. However, as a consequence, delayed healing was observed unless the patient was lucky enough to have the plate break. One way of dealing with this was to use a slotted plate in which the screws could move axially, but the really important advance was recognition of the role of compression. After the first description of compression by Danis with a "coapteur", Bagby and Müller with the AO improved the technique of compression. The classic dynamic compression plates from the 1970s were the key to a very rigid fixation, leading to primary bone healing. Nevertheless, the use of strong plates resulted in delayed union and the osteoporosis, cancellous bone, comminution, and/or pathological bone resulted in some failures due to insufficient stability. Finally, new devices represented by locking plates increased the stability, contributing to the principles of a more biological osteosynthesis while giving enough stability to allow immediate full weight bearing in some patients.

  6. Effect of plate working length on plate stiffness and cyclic fatigue life in a cadaveric femoral fracture gap model stabilized with a 12-hole 2.4?mm locking compression plate

    OpenAIRE

    Chao, Peini; Conrad, Bryan P; Lewis, Daniel D; Horodyski, MaryBeth; Pozzi, Antonio

    2013-01-01

    Background There are several factors that can affect the fatigue life of a bone plate, including the mechanical properties of the plate and the complexity of the fracture. The position of the screws can influence construct stiffness, plate strain and cyclic fatigue of the implants. Studies have not investigated these variables in implants utilized for long bone fracture fixation in dogs and cats. The purpose of the present study was to evaluate the effect of plate working length on construct ...

  7. A biomechanical comparison of one-third tubular plates versus periarticular plates for fixation of osteoporotic distal fibula fractures.

    Science.gov (United States)

    Davis, Adrian T; Israel, Heidi; Cannada, Lisa K; Bledsoe, J Gary

    2013-09-01

    The purpose of this study was to test the biomechanical properties of locking and nonlocking plates using one-third tubular and periarticular plate designs in an osteoporotic distal fibula fracture model. Twenty-four cadaveric specimens, whose bone mineral densities were obtained using dual x-ray absorptiometry scans, were tested. The fracture model simulated an OTA 44-B2.1 fracture. The constructs included (1) nonlocking one-third tubular plate, (2) locking one-third tubular plate, (3) nonlocking periarticular plate, and (4) locking periarticular plate. The specimens underwent axial loading followed by torsional loading to failure. Statistical analysis was performed using Kruskal-Wallis testing and further analysis with Mann-Whitney testing. The periarticular plates had greater rotational stiffness compared with the one-third tubular plates (P = 0.04). The nonlocking plates had greater torque to failure than the locking plates (P = 0.01). The nonlocking one-third tubular plate had greater torque to failure than the locking one-third tubular plate (P = 0.03). No significant differences were found in any of the comparisons regarding axial stiffness. In biomechanical testing using an osteoporotic model of OTA 44-B2.1 fractures, periarticular plates were superior to one-third tubular plates in rotational stiffness only. Locking plates did not outperform their nonlocking counterparts. Periarticular plates should be considered when treating osteoporotic distal fibula fractures, but one-third tubular plates and nonlocking plates provide adequate fixation for these injuries.

  8. CT diagnosis of occipital bone pacchionian depression

    International Nuclear Information System (INIS)

    Zhu Jianguo; Xu Xiaolin

    2004-01-01

    Objective: To improve the recognition of the CT findings of occipital bone pacchionian depression, in order to avoid misdiagnosis. Methods: occipital bone pacchionian depression underwent CT with plain scan and intravenous contrast enhancement in 11 cases, and then the CT findings were analyzed. Results: Occipital bone pacchionian depression situated beside the torcular herophilia in 11 cases. The depression or bone defect were found at occipital bone inner plate, they can reach diploe or outer plate and had no enhancement after contrast injection. Conclusions: CT scans play an important role in diagnosis and differential diagnosis of occipital bone pacchionian depression

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... taken of the unaffected limb, or of a child's growth plate (where new bone is forming), for ... around joints, and in evaluating the hips of children with congenital problems. top of page This page ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... taken of the unaffected limb, or of a child's growth plate (where new bone is forming), for ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... patient. top of page How does the procedure work? X-rays are a form of radiation like ... taken of the unaffected limb, or of a child's growth plate (where new bone is forming), for ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... limb, or of a child's growth plate (where new bone is forming), for comparison purposes. When the ... Exams Arthritis X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety How to Read Your Radiology Report ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... limb, or of a child's growth plate (where new bone is forming), for comparison purposes. When the ... From (your name): Your e-mail address: Personal message (optional): Bees: Wax: Notice: RadiologyInfo respects your privacy. ...

  14. Sigmoid plate dehiscence: Congenital or acquired condition?

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Zhaohui, E-mail: lzhtrhos@163.com [Capital Medical University, Beijing Tongren Hospital, No 1 Dong Jiao Min Street, Dongcheng District, Beijing 100730 (China); Li, Jing, E-mail: lijingxbh@yahoo.com.cn [Capital Medical University, Beijing Tongren Hospital, No 1 Dong Jiao Min Street, Dongcheng District, Beijing 100730 (China); Zhao, Pengfei, E-mail: zhaopengf05@163.com [Capital Medical University, Beijing Friendship Hospital, No 95 Yongan Road, Xicheng District, Beijing 100050 (China); Lv, Han, E-mail: chrislvhan@126.com [Capital Medical University, Beijing Friendship Hospital, No 95 Yongan Road, Xicheng District, Beijing 100050 (China); Dong, Cheng, E-mail: derc007@sina.com [Capital Medical University, Beijing Friendship Hospital, No 95 Yongan Road, Xicheng District, Beijing 100050 (China); Liu, Wenjuan, E-mail: wenjuanliu@163.com [Jining No. 1 People' s Hospital, No. 6 Health Street, Jining 272100 (China); Wang, Zhenchang, E-mail: cjr.wzhch@vip.163.com [Capital Medical University, Beijing Friendship Hospital, No 95 Yongan Road, Xicheng District, Beijing 100050 (China)

    2015-05-15

    Highlights: • CT with multiplanar reformations can accurately display the sigmoid platet dehiscence. • The prevalence of sigmoid plate dehiscence was no significant difference among different age groups. • The size of sigmoid plate bony defects were not statistically different among different age groups. • The sigmoid plate dehiscence is more commonly a congenital than an acquired condition. - Abstract: Background and purpose: The imaging features of sigmoid plate dehiscence-induced pulsatile tinnitus have been presented. The origin of the sigmoid plate dehiscence, however, remains unclear. Our aim was to assess the prevalence and extent of sigmoid plate dehiscence on computed tomography (CT) images in multiple age groups to determine whether this condition is more likely to be congenital or acquired. Materials and methods: We retrospectively reviewed contrast-enhanced CT images of sigmoid plates of temporal bones in 504 patients. Each temporal bone was characterized as normal or dehiscent. Patients were then subcategorized into four age groups, and the prevalence and extent of dehiscent sigmoid plates in each group were calculated and compared. Results: Overall, 80 patients had sigmoid plate dehiscence, nine of whom had it bilaterally. In successively older age groups, the prevalences of sigmoid plate dehiscence were 18.9%, 20.1%, 14.5%, and 12.7%, respectively. Respective average anteroposterior bony defect diameters were 3.7 ± 1.7, 3.0 ± 1.3, 3.1 ± 1.5, and 3.0 ± 1.1 mm. Respective average vertical bony defect diameters were 3.6 ± 2.3, 2.6 ± 1.2, 3.2 ± 1.5, and 3.0 ± 1.7 mm. The prevalence and extent of sigmoid plate dehiscence were not statistically different among the four age groups. Conclusions: The similar radiologic prevalence and extent of dehiscent sigmoid plates among the age groups suggest that the dehiscence is more commonly a congenital than an acquired condition.

  15. Sigmoid plate dehiscence: Congenital or acquired condition?

    International Nuclear Information System (INIS)

    Liu, Zhaohui; Li, Jing; Zhao, Pengfei; Lv, Han; Dong, Cheng; Liu, Wenjuan; Wang, Zhenchang

    2015-01-01

    Highlights: • CT with multiplanar reformations can accurately display the sigmoid platet dehiscence. • The prevalence of sigmoid plate dehiscence was no significant difference among different age groups. • The size of sigmoid plate bony defects were not statistically different among different age groups. • The sigmoid plate dehiscence is more commonly a congenital than an acquired condition. - Abstract: Background and purpose: The imaging features of sigmoid plate dehiscence-induced pulsatile tinnitus have been presented. The origin of the sigmoid plate dehiscence, however, remains unclear. Our aim was to assess the prevalence and extent of sigmoid plate dehiscence on computed tomography (CT) images in multiple age groups to determine whether this condition is more likely to be congenital or acquired. Materials and methods: We retrospectively reviewed contrast-enhanced CT images of sigmoid plates of temporal bones in 504 patients. Each temporal bone was characterized as normal or dehiscent. Patients were then subcategorized into four age groups, and the prevalence and extent of dehiscent sigmoid plates in each group were calculated and compared. Results: Overall, 80 patients had sigmoid plate dehiscence, nine of whom had it bilaterally. In successively older age groups, the prevalences of sigmoid plate dehiscence were 18.9%, 20.1%, 14.5%, and 12.7%, respectively. Respective average anteroposterior bony defect diameters were 3.7 ± 1.7, 3.0 ± 1.3, 3.1 ± 1.5, and 3.0 ± 1.1 mm. Respective average vertical bony defect diameters were 3.6 ± 2.3, 2.6 ± 1.2, 3.2 ± 1.5, and 3.0 ± 1.7 mm. The prevalence and extent of sigmoid plate dehiscence were not statistically different among the four age groups. Conclusions: The similar radiologic prevalence and extent of dehiscent sigmoid plates among the age groups suggest that the dehiscence is more commonly a congenital than an acquired condition

  16. Bone Diseases

    Science.gov (United States)

    ... avoid smoking and drinking too much alcohol. Bone diseases can make bones easy to break. Different kinds ... break Osteogenesis imperfecta makes your bones brittle Paget's disease of bone makes them weak Bones can also ...

  17. Create Your Plate

    Medline Plus

    Full Text Available ... Pacific Islanders American Indian/Alaska Native Programs Older Adults Family Link Diabetes EXPO Upcoming Diabetes EXPOs EXPO ... Plate! Click on the plate sections below to add your food choices. Reset Plate Share Create Your ...

  18. Effectiveness of plate augmentation for femoral shaft nonunion after nailing

    Directory of Open Access Journals (Sweden)

    Chin-Jung Lin

    2012-08-01

    Conclusion: Plate augmentation with retention of the nail with autologous bone grafting may be an effective and reliable alternative in treating nonunion of the femoral shaft fracture after open reduction and internal fixation with intramedullary nail.

  19. Surgical management of proximal splint bone fractures in the horse

    International Nuclear Information System (INIS)

    Peterson, P.R.; Pascoe, J.R.; Wheat, J.D.

    1987-01-01

    Fractures of Metacarpal and Metatarsal II and IV (the splint bones) were treated in 283 horses over an 11 year period. In 21 cases the proximal portion of the fractured bone was stabilized with metallic implants. One or more cortical bone screws were used in 11 horses, and bone plates were applied in 11 horses. One horse received both treatments. Complications of screw fixation included bone failure, implant failure, radiographic lucency around the screws, and proliferative new bone at the ostectomy site. Only two of the horses treated with screw fixation returned to their intended use. Complications of plate fixation included partial fixation failure (backing out of screws), wound drainage, and proliferative bony response around the plate. Six of the 11 horses treated by plate fixation returned to their intended use. The authors recommend consideration of plate fixation techniques for repair of fractures in the proximal third of the splint bone

  20. Receptor tyrosine kinase inhibition causes simultaneous bone loss and excess bone formation within growing bone in rats

    International Nuclear Information System (INIS)

    Nurmio, Mirja; Joki, Henna; Kallio, Jenny; Maeaettae, Jorma A.; Vaeaenaenen, H. Kalervo; Toppari, Jorma; Jahnukainen, Kirsi; Laitala-Leinonen, Tiina

    2011-01-01

    During postnatal skeletal growth, adaptation to mechanical loading leads to cellular activities at the growth plate. It has recently become evident that bone forming and bone resorbing cells are affected by the receptor tyrosine kinase (RTK) inhibitor imatinib mesylate (STI571, Gleevec (registered) ). Imatinib targets PDGF, ABL-related gene, c-Abl, c-Kit and c-Fms receptors, many of which have multiple functions in the bone microenvironment. We therefore studied the effects of imatinib in growing bone. Young rats were exposed to imatinib (150 mg/kg on postnatal days 5-7, or 100 mg/kg on postnatal days 5-13), and the effects of RTK inhibition on bone physiology were studied after 8 and 70 days (3-day treatment), or after 14 days (9-day treatment). X-ray imaging, computer tomography, histomorphometry, RNA analysis and immunohistochemistry were used to evaluate bone modeling and remodeling in vivo. Imatinib treatment eliminated osteoclasts from the metaphyseal osteochondral junction at 8 and 14 days. This led to a resorption arrest at the growth plate, but also increased bone apposition by osteoblasts, thus resulting in local osteopetrosis at the osteochondral junction. The impaired bone remodelation observed on day 8 remained significant until adulthood. Within the same bone, increased osteoclast activity, leading to bone loss, was observed at distal bone trabeculae on days 8 and 14. Peripheral quantitative computer tomography (pQCT) and micro-CT analysis confirmed that, at the osteochondral junction, imatinib shifted the balance from bone resorption towards bone formation, thereby altering bone modeling. At distal trabecular bone, in turn, the balance was turned towards bone resorption, leading to bone loss. - Research highlights: → 3-Day imatinib treatment. → Causes growth plate anomalies in young rats. → Causes biomechanical changes and significant bone loss at distal trabecular bone. → Results in loss of osteoclasts at osteochondral junction.

  1. Development and mechanical properties of a locking T-plate

    Directory of Open Access Journals (Sweden)

    Luciane R. Mesquita

    Full Text Available ABSTRACT: This study aimed to develop a locking T-plate and to evaluate its mechanical properties in synthetic models. A titanium 2.7mm T-plate was designed with a shaft containing three locked screw holes and one dynamic compression hole, and a head with two locked screw holes. Forty T-shaped polyurethane blocks, and 20 T-plates were used for mechanical testing. Six bone-plate constructs were tested to failure, three in axial compression and three in cantilever bending. Fourteen bone-plate constructs were tested for failure in fatigue, seven in axial compression and seven in cantilever bending. In static testing higher values of axial compression test than cantilever bending test were observed for all variables. In axial compression fatigue testing all bone-plate constructs withstood 1,000,000 cycles. Four bone-plate constructs failure occurred before 1,000,000 cycles in cantilever bending fatigue testing. In conclusion, the locking T-plate tested has mechanical properties that offer greatest resistance to fracture under axial loading than bending forces.

  2. Removal of symptomatic titanium fixation plates after craniotomy.

    Science.gov (United States)

    Gupta, Raghav; Adeeb, Nimer; Griessenauer, Christoph J; Moore, Justin M; Patel, Apar S; Thomas, Ajith J; Ogilvy, Christopher S

    2016-10-01

    Titanium fixation plates are routinely used for rigid fixation of bone flaps after craniotomy. In craniofacial surgery or after craniotomy involving orbitozygomatic osteotomies, these plates are occasionally removed because of infection, pain, protrusion, soft tissue erosion, and plate malfunction. However, plate removal because of pain and protrusion after craniotomy without orbitozygomatic osteotomy has rarely been reported. A retrospective analysis of all patients who underwent removal of cranial fixation plates after craniotomy, performed by the senior authors at one institution between 2014 and 2016, was conducted. A total of 319 patients underwent bone flap fixation after craniotomy using cranial fixation plates between 2014 and 2016. Five of those patients (1.6 %) had their cranial plates removed because of pain and protrusion. An additional four patients had a cranial fixation plate removed during that time frame with the original craniotomy performed before 2014. All nine patients had immediate resolution of symptoms after plate removal. We report our experience with cranial fixation plate removal because of pain and protrusion in patients who underwent craniotomy without orbitozygomatic osteotomy, particularly frontotemporal craniotomy. In an attempt to reduce this complication, we recently stopped placing a full-size burr hole in the keyhole area of a frontotemporal craniotomy, eliminating the need for a titanium burr hole cover plate.

  3. Dynamic plate osteosynthesis for fracture stabilization: how to do it

    Directory of Open Access Journals (Sweden)

    Juerg Sonderegger

    2010-01-01

    Full Text Available Plate osteosynthesis is one treatment option for the stabilization of long bones. It is widely accepted to achieve bone healing with a dynamic and biological fixation where the perfusion of the bone is left intact and micromotion at the fracture gap is allowed. The indications for a dynamic plate osteosynthesis include distal tibial and femoral fractures, some midshaft fractures, and adolescent tibial and femoral fractures with not fully closed growth plates. Although many lower limb shaft fractures are managed successfully with intramedullary nails, there are some important advantages of open-reduction-and-plate fixation: the risk of malalignment, anterior knee pain, or nonunion seems to be lower. The surgeon performing a plate osteosynthesis has the possibility to influence fixation strength and micromotion at the fracture gap. Long plates and oblique screws at the plate ends increase fixation strength. However, the number of screws does influence stiffness and stability. Lag screws and screws close to the fracture site reduce micromotion dramatically. Dynamic plate osteosynthesis can be achieved by applying some simple rules: long plates with only a few screws should be used. Oblique screws at the plate ends increase the pullout strength. Two or three holes at the fracture site should be omitted. Lag screws, especially through the plate, must be avoided whenever possible. Compression is not required. Locking plates are recommended only in fractures close to the joint. When respecting these basic concepts, dynamic plate osteosynthesis is a safe procedure with a high healing and a low complication rate. 

  4. Mandibular reconstruction using a titanium plate: the impact of radiation therapy on plate preservation

    International Nuclear Information System (INIS)

    Ryu, Janice K.; Stern, Robin L.; Robinson, Marilyn G.; Bowers, Michael K.; Kubo, Hideo D.; Donald, Paul J.; Rosenthal, Seth A.; Fu, Karen K.

    1995-01-01

    Purpose: To evaluate the soft tissue and bone tolerance of radiation therapy (RT) in patients undergoing radical composite resection and mandibular reconstruction using a bridging titanium plate with myocutaneous flap closure. Methods and Materials: From 1990 to 1994, 47 patients with primary or recurrent oral cavity or oropharyngeal carcinomas were treated with radical composite resection and mandibular reconstruction using a bridging titanium plate with myocutaneous flap closure. Eleven patients received no RT (no RT), 10 patients received RT greater than 10 months from the time of surgery (remote RT), and 26 patients received RT within 12 weeks of surgery (perioperative RT). The radiation dose to the reconstructed mandible ranged from 45 to 75 Gy (median 63 Gy). The effect of the titanium plate on the radiation dose was measured using film dosimetry and soft tissue and bone-equivalent materials. The median follow-up was 17 months (range: 3-50 months). Results: Late complications included four patients with osteomyelitis or necrosis, two plate exposures requiring flap revision, one chronic infection, two cases of chronic pain, two fistulae, and one case of trismus and malocclusion. The crude incidence of late complications by treatment was: (a) no RT: 3 of 11 patients (27%); (b) remote RT: 2 of 10 patients (20%); and (c) perioperative RT: 9 of 26 patients (35%). One patient in the no-RT group lost the plate due to chronic pain. Five patients in the perioperative RT group also had plate loss, four due to osteomyelitis and/or necrosis, and one due to pain related to a recurrent tumor. No patients in the remote RT group had plate loss. The actuarial prosthesis preservation rate at 2 years was 88% for the no RT, 100% for the remote RT, and 57% for the perioperative RT groups (p = 0.05). Phantom dose measurements showed that for parallel opposed 6 MV photon beams, there was no significant increase in the dose proximal or distal to the plate in either a soft tissue- or

  5. Locking plate fixation for proximal humerus fractures.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2012-02-01

    Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for proximal humeral fractures should involve minimal soft tissue dissection and achieve anatomic reduction of the head complex with sufficient stability to allow for early shoulder mobilization. This article reviews various treatment options, in particular locking plate fixation. Locking plate fixation is associated with a high complication rate, such as avascular necrosis (7.9%), screw cutout (11.6%), and revision surgery (13.7%). These complications are frequently due to the varus deformation of the humeral head. Strategic screw placement in the humeral head would minimize the possibility of loss of fracture reduction and potential hardware complications. Locking plate fixation is a good surgical option for the management of proximal humerus fractures. Complications can be avoided by using better bone stock and by careful screw placement in the humeral head.

  6. A computed microtomography method for understanding epiphyseal growth plate fusion

    Science.gov (United States)

    Staines, Katherine A.; Madi, Kamel; Javaheri, Behzad; Lee, Peter D.; Pitsillides, Andrew A.

    2017-12-01

    The epiphyseal growth plate is a developmental region responsible for linear bone growth, in which chondrocytes undertake a tightly regulated series of biological processes. Concomitant with the cessation of growth and sexual maturation, the human growth plate undergoes progressive narrowing, and ultimately disappears. Despite the crucial role of this growth plate fusion ‘bridging’ event, the precise mechanisms by which it is governed are complex and yet to be established. Progress is likely hindered by the current methods for growth plate visualisation; these are invasive and largely rely on histological procedures. Here we describe our non-invasive method utilising synchrotron x-ray computed microtomography for the examination of growth plate bridging, which ultimately leads to its closure coincident with termination of further longitudinal bone growth. We then apply this method to a dataset obtained from a benchtop microcomputed tomography scanner to highlight its potential for wide usage. Furthermore, we conduct finite element modelling at the micron-scale to reveal the effects of growth plate bridging on local tissue mechanics. Employment of these 3D analyses of growth plate bone bridging is likely to advance our understanding of the physiological mechanisms that control growth plate fusion.

  7. Create Your Plate

    Medline Plus

    Full Text Available ... Student Resources History of Diabetes Resources for School Projects How to Reference Our Site Diabetes Basics Myths ... Your Plate It's simple and effective for both managing diabetes and losing weight. Creating your plate lets ...

  8. Create Your Plate

    Medline Plus

    Full Text Available ... Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook ... Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart- ...

  9. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal ... Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook ...

  10. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate It's simple and effective for both managing diabetes and losing weight. Creating your plate lets you still choose the foods you want, but changes the portion sizes so you are getting larger ...

  11. Williamson Polishing & Plating Site

    Science.gov (United States)

    Williamson Polishing & Plating Co. Inc. was a plating shop located in the Martindale-Brightwood neighborhood of Indianapolis. The facility conducted job shop polishing and electroplating services. The vacant site contains a 14,651-square-foot building.

  12. In vitro biomechanical comparison of limited contat dynamic compression plate and locking compression plate.

    Science.gov (United States)

    Aguila, A Z; Manos, J M; Orlansky, A S; Todhunter, R J; Trotter, E J; Van der Meulen, M C H

    2005-01-01

    The locking compression plate (LCP) supports biological osteosynthesis by functioning as an internal fixator, rather than as a full or limited contact bone plate which must be adequately contoured and affixed directly to the bone for stable internal fixation of the fracture. In order to help justify the use of the LCP in our veterinary patients, in vitro biomechanical testing was performed comparing the LCP to the conventional limited contact dynamic compression plate (LC-DCP) in canine femurs. We hypothesized that the LCP construct would be at least as stiff under bending and torsional loads as the LC-DCP. The LCP and LC-DCP were applied over a 20-mm osteotomy gap to contralateroal bones within each pair of 14 femora. Non-destructive four-point bending and torsion, and cyclical testing in torsion were performed. The constructs were then loaded to failure in torsion. In medial-lateral and lateral-medial structural bending, significant differences were not found between the LCP and LC-DCP, however, at the gap, the LCP construct was stiffer than the LC-DCP in lateral-medial bending. Significant differences in behaviour over time were not noted between the plate designs during cyclical testing. When loading the constructs to failure in internal rotation, the LC-DCP failed at a significantly lower twist angle (P = .0024) than the LCP. Based on the similar performance with loading, the locking compression plate is a good alternative implant for unstable diaphyseal femoral fracture repair in dogs.

  13. Vibration of plates

    CERN Document Server

    Chakraverty, Snehashish

    2008-01-01

    Plates are integral parts of most engineering structures and their vibration analysis is required for safe design. This work provides a comprehensive introduction to vibration theory and analysis of two-dimensional plates. It offers information on vibration problems along with a discussion of various plate geometries and boundary conditions.

  14. Bone Cancer

    Science.gov (United States)

    Cancer that starts in a bone is uncommon. Cancer that has spread to the bone from another ... more common. There are three types of bone cancer: Osteosarcoma - occurs most often between ages 10 and ...

  15. Modic changes in lumbar spine: prevalence and distribution patterns of end plate oedema and end plate sclerosis.

    Science.gov (United States)

    Xu, Lei; Chu, Bin; Feng, Yang; Xu, Feng; Zou, Yue-Fen

    2016-01-01

    not just mean Modic Type III but does exist in all types of Modic changes, especially in mixed Modic types, and may reflect vertebral body mineralization rather than change in the bone marrow. End plate oedema and end plate sclerosis are present in a large proportion of mixed types.

  16. Resultados de tratamento cirúrgico da pseudoartrose de fratura diafisária do úmero com placa de compressão dinâmica e enxerto de osso esponjoso Results of surgical treatment of nonunion of humeral shaft fracture with dynamic compression plate and cancellous bone grafting

    Directory of Open Access Journals (Sweden)

    Olasinde Anthony Ayotunde

    2012-01-01

    Full Text Available OBJETIVO: Avaliamos o tratamento da pseudoartrose de fratura diafisária do úmero com placa de compressão dinâmica de janeiro de 2002 a dezembro de 2009. MÉTODOS: Vinte e dois pacientes foram tratados durante o período do estudo. O trauma foi a causa predominante de lesão em 86,4% dos pacientes. RESULTADOS: A pseudoartrose foi atrófica em 81,8% e hipertrófica em 18,2% dos indivíduos. Havia lesão primária do nervo radial nervo em 27,3% dos pacientes. Todos os participantes tinham fratura fechada à apresentação e 81,2% deles tinham recebido tratamento anterior de traditional bone setters (pessoa que faz a redução de ossos quebrados ou deslocados, geralmente sem ser médico licenciado e 18,8% tinham falha do tratamento conservador com gesso. O tempo médio até a união foi 16 semanas. O tratamento anterior com traditional bone setters afetou significantemente o tempo de consolidação da fratura (p OBJECTIVE: We evaluated the treatment of nonunion of humeral shaft fracture with dynamic compression plate from January 2002 to December 2009. METHODS: Twenty two patients were treated over the study period. Trauma was the predominant cause of injury in 86,4% of the patients. RESULTS: Nonunion was atrophic in 81,8% and hypertrophic in 18,2% of the individuals. There was a primary injury of the radial nerve in 27,3% of the patients. All the participants had closed fracture at presentation, and 81,2% had received previous treatment from traditional bone setters and 18,8% had failure of the conservative cast management.The average time to healing was 16 weeks. Previous treatment from traditional bone setters significantly affected the time to fracture healing (p<0,05. All fractures had successful union. CONCLUSION: It was concluded that dynamic compression plating remains an effective treatment option for nonunion of humeral shaft fracture. Level of Evidence III, Retrospective study.

  17. Padronização de um método para mensuração das tábuas ósseas vestibular e lingual dos maxilares na Tomografia Computadorizada de Feixe Cônico (Cone Beam Methodology standardization for measuring buccal and lingual alveolar bone plates using Cone Beam Computed Tomography

    Directory of Open Access Journals (Sweden)

    Marcos Cezar Ferreira

    2010-02-01

    Full Text Available INTRODUÇÃO: a espessura das tábuas ósseas que recobrem os dentes por vestibular e lingual constitui um dos fatores limitantes da movimentação dentária. O avanço tecnológico em Imaginologia permitiu avaliar detalhadamente essas regiões anatômicas por meio da utilização da tomografia computadorizada de feixe cônico (TCFC. OBJETIVO: descrever e padronizar, pormenorizadamente, um método para mensuração das tábuas ósseas vestibular e lingual dos maxilares nas imagens de tomografia computadorizada de feixe cônico. METODOLOGIA: a padronização digital da posição da imagem da face deve constituir o primeiro passo antes da seleção dos cortes de TCFC. Dois cortes axiais de cada maxilar foram empregados para a mensuração da espessura do osso alveolar vestibular e lingual. Utilizou-se como referência a junção cemento-esmalte dos primeiros molares permanentes, tanto na arcada superior quanto na inferior. RESULTADOS: cortes axiais paralelos ao plano palatino foram indicados para avaliação quantitativa do osso alveolar na maxila. Na arcada inferior, os cortes axiais devem ser paralelos ao plano oclusal funcional. CONCLUSÃO: o método descrito apresenta reprodutibilidade para utilização em pesquisas, assim como para a avaliação clínica das repercussões periodontais da movimentação dentária, ao permitir a comparação de imagens pré e pós-tratamento.INTRODUCTION: The thickness of the buccal and lingual bone plates constitutes one of the limiting factors of the orthodontic movement. The imaging technology has permitted the evaluation of this anatomical region, by means of cone beam computed tomography. PURPOSE: To describe and standardize, in details, a method for measuring the buccal and lingual bone plate thickness in CBCT images. METHODOLOGY: Digital standardization of face image should constitute the first step before the selection of CBCT slices. Two axial sections of each jaw were used for measuring the thickness

  18. Low Bone Density

    Science.gov (United States)

    ... Bone Density Exam/Testing › Low Bone Density Low Bone Density Low bone density is when your bone ... to people with normal bone density. Detecting Low Bone Density A bone density test will determine whether ...

  19. Differentiation of bone marrow cells with irradiated bone in vitro

    International Nuclear Information System (INIS)

    Toshiyuki Tominaga; Moritoshi Itoman; Izumi, T.; Wakita, R.; Uchino, M.

    1999-01-01

    Disease transmission or infection is an important issue in bone allograft, and irradiation is used for sterilization of graft bones. One of the advantages of bone allograft over biomaterials is that graft bones have osteoinductive factors such as growth factors. Irradiation is reported to decrease the osteoinductive activity in vivo. We investigated the osteoinductive activity of irradiated bone by alkaline phosphatase (ALP) activity in rat bone marrow cell culture. Bones (tibias and femurs of 12-week-old Wistar rats) were cleaned of adhering soft tissue, and the marrow was removed by washing. The bones were defatted, lyophilized, and cut into uniform 70 mg fragments. Then the Bone fragments were irradiated at either 10, 20, 25, 30, 40, or 50 kGy at JAERI. Bone marrow cells were isolated from tibias and femurs of 4-week-old Wistar rats. Cells were plated in tissue culture flask. When primary cultures reached confluence, cells were passaged (4 x 103 cell / cm2) to 6 wells plates. The culture medium consisted of minimum essential medium, 10% fetal bovine serum, ascorbic acid, and antibiotics. At confluence, a cell culture insert was set in the well, and an irradiated bone fragment was placed in it. Then, medium was supplemented with 10 mM ?-glycerophosphate and 1 x 10-8 M dexamethasone. Culture wells were stained by naphthol AS-MX phosphate, N,N-dimethyl formamide, Red violet LB salt on day 0, 7, 14. The density of ALP staining was analyzed by a personal computer. Without bones, ALP staining increased by 50% on day 7 and by 100% on day 14, compared with that on day 0. The other side, with bones irradiated at 30 kGy or lower, ALP staining increased by 150% on day 7, and by 180% on day 14, compared with that on day 0. In the groups of irradiated bones of 40 kGy or higher, the increase in ALP staining was less prominent compared with the groups of irradiated bones of 30 kGy or lower. In the groups of 0-30 kGy irradiation, ALP staining increased in the early period

  20. Bone scintigraphy in children: trauma

    Energy Technology Data Exchange (ETDEWEB)

    Harcke, H.T. (Alfred I. du Pont Institute, Wilmington, DE (USA))

    1983-12-01

    The sensitivity of radionuclide imaging in identifying skeletal trauma in children has been established. Growth plates present a set of problems unique to pediatric studies and diagnotic accuracy is very technique dependent. Imaging for sports injuries and suspected child abuse has been productive. An expanding role for bone scintigraphy in the management of orthopedic problems post-trauma is developing.

  1. Bone scintigraphy in children: trauma

    International Nuclear Information System (INIS)

    Harcke, H.T.

    1983-01-01

    The sensitivity of radionuclide imaging in identifying skeletal trauma in children has been established. Growth plates present a set of problems unique to pediatric studies and diagnotic accuracy is very technique dependent. Imaging for sports injuries and suspected child abuse has been productive. An expanding role for bone scintigraphy in the management of orthopedic problems post-trauma is developing [fr

  2. Management of Bone Gaps with Intramedullary Autologous Fibular ...

    African Journals Online (AJOL)

    ... 7 consecutive patients who presented with bone gaps that were managed with intramedullary non vascularised fibular strut graft. Method: Intramedulary Autologous fibular strut graft was used to breach the bone and the whole length augmented with cancellous graft and bridged with bone plate; external fixators or k wires.

  3. Fracture repair using a polyaxial locking plate system (PAX).

    Science.gov (United States)

    Barnhart, Matthew D; Rides, Cristobal F; Kennedy, Shawn C; Aiken, Sean W; Walls, Charles M; Horstman, Christopher L; Mason, David; Chandler, Jonathon C; Brourman, Jeff D; Murphy, Sean M; Pike, Frederick; Naber, Steven J

    2013-01-01

    To report outcomes and complications of dog and cat fractures treated with the polyaxial locking plate system (PAX). Case series. Dogs (n = 60) and 2 cats. Medical records (December 2009-March 2011) of dogs and cats with fractures treated with the PAX system were reviewed. Cases with adequate follow-up to document a functional union, had surgery performed by an author, had no prior treatment of the fracture(s), and with complete operative records were included. Signalment, body weight, bone(s) fractured, area of bone fractured, fracture classification, concurrent orthopedic injuries, complications, time to functional union, if minimally invasive plate osteosynthesis (MIPO) techniques were used, plate size, number of plates, bone graft use, and ancillary methods of fixation were recorded. Additionally, fracture segment: plate length, screw, number of plate holes, number of empty screw holes overlying/adjacent to the fractures, number of cortices engaged above/below the fracture was evaluated. Variables were evaluated statistically for effect on complications and functional union. Sixty-two animals were included. Mean time to functional union was 7.1 weeks. Complications occurred in 12 animals (19%) and plate failure occurred in 3 (5%). Statistically significant factors that affected time to functional union were the presence of multiple injuries and age. Those associated with complications were double plates and number of cortices engaged above and below fractures. The PAX system allows for multidirectional screw insertion with an overall complication rate and time to functional union similar to other fracture repair implant systems. © Copyright 2012 by The American College of Veterinary Surgeons.

  4. Create Your Plate

    Medline Plus

    Full Text Available ... Monthly In Memory In Honor Become a Member En Español Type 1 Type 2 About Us Online ... Print Page Text Size: A A A Listen En Español Create Your Plate Create Your Plate is ...

  5. Create Your Plate

    Medline Plus

    Full Text Available ... Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning ... Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets ...

  6. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning What Can I Eat? Making ... Forecast® magazine: wcie-meal-planning, . In this ... Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook ...

  7. Create Your Plate

    Medline Plus

    Full Text Available ... In Memory In Honor Become a Member En Español Type 1 Type 2 About Us Online Community ... Page Text Size: A A A Listen En Español Create Your Plate Create Your Plate is a ...

  8. Create Your Plate

    Medline Plus

    Full Text Available ... Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart- ... Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy Foods ...

  9. CAD-CAM plates versus conventional fixation plates for primary mandibular reconstruction: A biomechanical in vitro analysis.

    Science.gov (United States)

    Rendenbach, Carsten; Sellenschloh, Kay; Gerbig, Lucca; Morlock, Michael M; Beck-Broichsitter, Benedicta; Smeets, Ralf; Heiland, Max; Huber, Gerd; Hanken, Henning

    2017-11-01

    CAD/CAM reconstruction plates have become a viable option for mandible reconstruction. The aim of this study was to determine whether CAD/CAM plates provide higher fatigue strength compared with conventional fixation systems. 1.0 mm miniplates, 2.0 mm conventional locking plates (DePuy Synthes, Umkirch, Germany), and 2.0 mm CAD/CAM plates (Materialise, Leuven, Belgium/DePuy Synthes) were used to reconstruct a polyurethane mandible model (Synbone, Malans, CH) with cortical and cancellous bone equivalents. Mastication was simulated via cyclic dynamic testing using a universal testing machine (MTS, Bionix, Eden Prairie, MN, USA) until material failure reached a rate of 1 Hz with increasing loads on the left side. No significant difference was found between the groups until a load of 300 N. At higher loads, vertical displacement differed increasingly, with a poorer performance of miniplates (p = 0.04). Plate breakage occurred in miniplates and conventional locking plates. Screw breakage was recorded as the primary failure mechanism in CAD/CAM plates. Stiffness was significantly higher with the CAD/CAM plates (p = 0.04). CAD/CAM plates and reconstruction plates provide higher fatigue strength than miniplates, and stiffness is highest in CAD/CAM systems. All tested fixation methods seem sufficiently stable for mandible reconstruction. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Bone marrow aspiration

    Science.gov (United States)

    Iliac crest tap; Sternal tap; Leukemia - bone marrow aspiration; Aplastic anemia - bone marrow aspiration; Myelodysplastic syndrome - bone marrow aspiration; Thrombocytopenia - bone marrow aspiration; Myelofibrosis - bone marrow aspiration

  11. Comparison of modern locked plating and antiglide plating for fixation of osteoporotic distal fibular fractures.

    Science.gov (United States)

    Switaj, Paul J; Wetzel, Robert J; Jain, Neel P; Weatherford, Brian M; Ren, Yupeng; Zhang, Li-Qun; Merk, Bradley R

    2016-09-01

    Fractures in osteoporotic patients can be difficult to treat because of poor bone quality and inability to gain screw purchase. The purpose of this study is to compare modern lateral periarticular distal fibula locked plating to antiglide plating in the setting of an osteoporotic, unstable distal fibula fracture. AO/OTA 44-B2 distal fibula fractures were created in sixteen paired fresh frozen cadaveric ankles and fixed with a lateral locking plate and an independent lag screw or an antiglide plate with a lag screw through the plate. The specimens underwent stiffness, cyclic loading, and load to failure testing. The energy absorbed until failure, torque to failure, construct stiffness, angle at failure, and energy at failure was recorded. The lateral locking construct had a higher torque to failure (p=0.02) and construct stiffness (p=0.04). The locking construct showed a trend toward increased angle at failure, but did not reach statistical significance (p=0.07). Seven of the eight lateral locking plate specimens failed through the distal locking screws, while the antiglide plating construct failed with pullout of the distal screws and displacement of the fracture in six of the eight specimens. In our study, the newly designed distal fibula periarticular locking plate with increased distal fixation is biomechanically stronger than a non-locking one third tubular plate applied in antiglide fashion for the treatment of AO/OTA 44-B2 osteoporotic distal fibula fractures. V: This is an ex-vivo study performed on cadavers and is not a study performed on live patients. Therefore, this is considered Level V evidence. Copyright © 2015. Published by Elsevier Ltd.

  12. Superconstructs in the treatment of charcot foot deformity: plantar plating, locked plating, and axial screw fixation.

    Science.gov (United States)

    Sammarco, V James

    2009-09-01

    Management of Charcot's deformity of the foot and ankle continues to challenge physicians. Medical co-morbidity, peripheral neuropathy, vascular disease, and immune impairment cause severe problems for these patients and, when combined with neuroarthropathy, can lead to amputation. Progressive bony deformity and bone resorption, which may accompany neuroarthropathy, only increase the challenge of surgical treatment. These challenges have led physicians to develop "superconstruct" techniques to improve fixation, whereby fusion is extended beyond the zone of injury to include joints that are not affected, bone resection is performed to shorten the extremity to allow for adequate reduction of deformity without undue tension on the soft tissue envelope, the strongest device is used that can be tolerated by the soft tissue envelope; and the devices are applied in a novel position that maximizes mechanical function. This article reviews three techniques designed to achieve lasting deformity correction and successful arthrodesis: plantar plating, locked plating, and axial screw fixation.

  13. Lohse's historic plate archive

    Science.gov (United States)

    Tsvetkov, M.; Tsvetkova, K.; Richter, G.; Scholz, G.; Böhm, P.

    The description and the analysis of Oswald Lohse's astrophotographic plates, collected at the Astrophysical Observatory Potsdam in the period 1879 - 1889, are presented. 67 plates of the archive, taken with the greatest instrument of the observatory at that time - the refractor (D = 0.30 m, F = 5.40 m, scale = 38''/mm) and with the second heliographic objective (D = 0.13 m, F = 1.36 m, scale = 152''/mm) - - survived two world wars in relative good condition. The plate emulsions are from different manufacturers in the beginning of astrophotography (Gädicke, Schleussner, Beernaert, etc.). The sizes of the plates are usually 9x12 cm2, which corresponds to fields of 1.2deg and 5deg respectively for each instrument mentioned above. The average limiting magnitude is 13.0(pg). Besides of the plates received for technical experiments (work on photographic processes, testing of new instruments and methods of observations), the scientific observations follow programs for studies of planet surfaces, bright stars, some double stars, stellar clusters and nebulous objects. Lohse's archive is included into the Wide Field Plate Database (http://www.skyarchive.org) as the oldest systematic one, covering the fields of Orion (M42/43), Pleiades, h & chi Persei, M37, M3, M11, M13, M92, M31, etc. With the PDS 2020 GM+ microdensitometer of Münster University 10 archive plates were digitized.

  14. Aramid-epoxy composite internal fixation plates: a pilot study.

    Science.gov (United States)

    Cochran, G V; Palmieri, V R; Zickel, R E

    1994-09-01

    Mechanical tests were conducted on an aramid-epoxy composite laminate in vitro and in vivo to determine its suitability for internal fixation plates. This material, fashioned into blank test coupons the size of the standard 4-hole AO-ASIF plates, had a tensile modulus of elasticity significantly lower than bone. In three-point bending, blank test coupons exhibited a low yield strength that would limit utility in significant load-bearing situations, but changes in the layer configuration of the composite could be expected to improve this characteristic. Under destructive loads, these specimens appeared to be less subject to catastrophic failure than carbon fibre composites. Using 4-hole test coupons fastened to a plastic tube simulating bone, four-point bending tests showed that strain-shielding was significantly reduced by aramid composite relative to carbon fibre composite or metal plates. Finally, in-vivo tests on canine femora demonstrated that aramid composite plates were well tolerated and caused less strain shielding during weightbearing, but significant differences in cortical atrophy and porosity beneath steel versus aramid plates were not apparent. Although the plates were relatively flexible, they could not be preformed during surgery like a metal plate. Copyright © 1994. Published by Elsevier Ltd.

  15. High loading uranium plate

    International Nuclear Information System (INIS)

    Wiencek, T.C.; Domagala, R.F.; Thresh, H.R.

    1990-01-01

    Two embodiments of a high uranium fuel plate are disclosed which contain a meat comprising structured uranium compound confined between a pari of diffusion bonded ductile metal cladding plates uniformly covering the meat, the meat hiving a uniform high fuel loading comprising a content of uranium compound greater than about 45 Vol. % at a porosity not greater than about 10 Vol. %. In a first embodiment, the meat is a plurality of parallel wires of uranium compound. In a second embodiment, the meat is a dispersion compact containing uranium compound. The fuel plates are fabricated by a hot isostatic pressing process

  16. Treatment of midshaft clavicular delayed and non-unions with anteroinferior locking compression plating

    NARCIS (Netherlands)

    Stufkens, S.A.; Kloen, P.

    2010-01-01

    INTRODUCTION: Pain and impaired shoulder function are the predominant symptoms of midshaft clavicle non-unions. Obtaining consolidation and improvement of shoulder function is often successfully achieved with osteosynthesis and bone grafting. Most data in the literature pertain to plate

  17. Create Your Plate

    Medline Plus

    Full Text Available ... managing diabetes and losing weight. Creating your plate lets you still choose the foods you want, but ... you have an easy portion control solution that works. Last Reviewed: October 8, 2015 Last Edited: September ...

  18. What's On Your Plate?

    Science.gov (United States)

    ... what these nutrients do in your body and what foods they are found in. Plans for Healthy Living ... food choices. Get more nutrition information online with What's On Your Plate? Smart Food Choices for Healthy Aging from the National Institute ...

  19. Create Your Plate

    Medline Plus

    Full Text Available ... Plate is a simple and effective way to manage your blood glucose levels and lose weight. With ... been easier. It can be a challenge to manage portion control wherever you are. Now, our best- ...

  20. Create Your Plate

    Medline Plus

    Full Text Available ... Count Glycemic Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ...

  1. Create Your Plate

    Medline Plus

    Full Text Available ... Edited: September 14, 2016 Articles from Diabetes Forecast® magazine: wcie-meal-planning, . In this section Food Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten ...

  2. Create Your Plate

    Medline Plus

    Full Text Available ... Children and Type 2 Diabetes Know Your Rights Employment Discrimination Health Care Professionals Law Enforcement Driver's License ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ...

  3. Humvee Armor Plate Drilling

    National Research Council Canada - National Science Library

    2004-01-01

    When drilling holes in hard steel plate used in up-armor kits for Humvee light trucks, the Anniston Army Depot, Anniston, Alabama, requested the assistance of the National Center for Defense Manufacturing and Machining (NCDMM...

  4. Create Your Plate

    Medline Plus

    Full Text Available ... one side, cut it again so you will have three sections on your plate. Fill the largest ... home, the office, or somewhere in between, you have an easy portion control solution that works. Last ...

  5. Comparative performance of locally made and the foreign made dynamic compression plates

    International Nuclear Information System (INIS)

    Bilal, M.; Gul, R.M.; Mujahid, M.; Askar, Z.

    2011-01-01

    Bone implants are widely used to treat patients due to trauma in different causalities. The major types of bone implants are plates known as Dynamic Compression Plates (DCP) and nails, both made of stainless steel (AISI 316L Grade). In Pakistan both local made and foreign made (DCP) are available. The unit price of foreign made DCP is about 8 to 10 times that of the local made, however, no comprehensive study has been done on the comparison of these plates. An in-depth analysis was performed to compare the essential properties of six different brands of DCP including two foreign, two local and two unknown brands. These properties included mechanical properties, such as bending stiffness, yield strength, modulus of elasticity and hardness. Compositional analysis and various dimensions of plate important for bone healing process were also compared. The results show that all plates have similar mechanical properties. The compositional analysis showed some variations from the ASTM standards for most of the plates. The dimensional analysis of plates showed that Slot Width and Land were within range for most of the plates but the Spherical Radius was out of range for all the plates. Generally, all plates have no major differences in their properties, material and shape. (author)

  6. Reprodutibilidade das mensurações da espessura das tábuas ósseas na tomografia computadorizada Cone-Beam utilizando diferentes protocolos de aquisição de imagem Reproducibility of bone plate thickness measurements with Cone-Beam Computed Tomography using different image acquisition protocols

    Directory of Open Access Journals (Sweden)

    Carolina Carmo de Menezes

    2010-10-01

    Full Text Available INTRODUÇÃO: quanto menor a dimensão do voxel, maior a nitidez da imagem de tomografia computadorizada Cone-Beam (TCCB, porém, maior a dose de radiação emitida. OBJETIVOS: avaliar e comparar a reprodutibilidade da mensuração da espessura das tábuas ósseas vestibular e lingual em imagens de TCCB, utilizando diferentes protocolos de aquisição de imagem com variação da dimensão do voxel. MÉTODOS: exames de TCCB foram tomados de 12 mandíbulas humanas secas, com dimensão do voxel de 0,2; 0,3 e 0,4mm, no aparelho i-CAT Cone-Beam 3-D Dental Imaging System. No software i-CAT Viewer, foi mensurada a espessura das tábuas ósseas vestibular e lingual, em um corte axial passando 12mm acima do forame mentoniano do lado direito. A reprodutibilidade intraexaminador foi avaliada por meio da aplicação do teste t pareado. Para a comparação interexaminadores, foi utilizado o teste t independente. Os resultados foram considerados com o nível de significância de 5%. RESULTADOS: observou-se uma excelente reprodutibilidade interexaminadores para os três protocolos avaliados. A reprodutibilidade intraexaminadores foi muito boa, com exceção de algumas regiões dos dentes anteriores, que mostraram diferenças estatisticamente significativas, independentemente da dimensão do voxel. CONCLUSÃO: a mensuração da espessura das tábuas ósseas vestibular e lingual em imagens de TCCB mostrou boa precisão para exames obtidos com voxel de 0,2; 0,3 ou 0,4mm. A reprodutibilidade das mensurações na região anterior da mandíbula foi mais crítica do que na região posterior.INTRODUCTION: A smaller voxel dimension leads to greater resolution of Cone-Beam Computed Tomography (CBCT, but a greater dosage of radiation is emitted. OBJECTIVE: Assess and compare the reproducibility of buccal and lingual bone plate thickness measurements in CBCT images using different image acquisition protocols, with variations in the voxel dimension. METHODS: CBCT exams

  7. Neutron imaging plates

    International Nuclear Information System (INIS)

    Niimura, Nobuo

    1995-01-01

    Imaging plates have been used in the field of medical diagnosis since long ago, but their usefulness was verified as the two-dimensional detector for analyzing the X-ray crystalline structure of high bio molecules like protein, and they have contributed to the remarkable progress in this field. The great contribution is due to the excellent features, such as the detection efficiency of about 100%, the positional resolution smaller than 0.2 mm, the dynamic range of five digits, and the area of several hundreds mm square. The neutron imaging plates have not yet obtained the sufficient results. It was planned to construct the neutron diffractometer for biological matters, and to put imaging plate neutron detectors (IP-ND) to practical use as the detector. The research on the development of IP-NDs was carried out, and the IPp-NDs having the performance comparable with that for X-ray were able to be produced. Imaging plates are the integral type two-dimensional radiation detector using photostimulated luminescence matters, and their principle is explained. As to neutron imaging plates, the converter, neutron detection efficiency and the flight of secondary particles in photo-stimulated luminescence matters are described. As for the present state of development of neutron imaging plates, the IP-NDs made for trial, the dynamic range, the positional resolution, the detection efficiency and the kinds of converters, and the application of IP-NDs are reported. (K.I.)

  8. Osseointegration of dental implants placed into canine mandibular bone regenerated by bone transport distraction osteogenesis.

    Science.gov (United States)

    Kontogiorgos, Elias; Elsalanty, Mohammed E; Zakhary, Ibrahim; Nagy, William W; Dechow, Paul C; Opperman, Lynne A

    2013-01-01

    The purpose of this study was to compare the osseointegration of dental implants placed in canine mandibular bone and in regenerated bone produced by bone transport distraction osteogenesis. Ten adult foxhounds were divided into two groups of five animals each. In all animals, a 40-mm defect was created on one side of the mandible. A bone transport reconstruction plate was used to stabilize the mandible and regenerate bone. Six weeks after the distraction period was finished, dental implants were placed in regenerated and native mandibular bone. The animals were sacrificed after another 6 and 12 weeks of healing, respectively. Microcomputed tomographic evaluation showed that bone volume fraction (BV/TV) was greater at the coronal regions of the implants and decreased toward the apical regions. There was an increase in BV/TV around implants placed in regenerated bone from 6 to 12 weeks of healing. The regenerated group showed lower BV/TV at 6 weeks versus implants placed in native bone but had reached the same levels as the native bone at 12 weeks. Histology showed that direct bone-to-implant contact was greater for implants placed in native bone than for those placed in regenerated bone for both time periods. The removal torque of the implants placed in native bone was higher at 6 weeks than that of implants placed in regenerated bone. At 12 weeks, there were no statistically significant differences in removal torque between the groups. Bone was successfully regenerated in all animals. The implants placed entirely in regenerated bone were osseointegrated. The regenerated bone around the implants became denser over time. This finding suggests that implants placed entirely in regenerated bone will be as well integrated as implants in native mandibular bone by 12 weeks after placement.

  9. [Repairing bone defects of benign bone neoplasm by grafting of bioactive glass combined with autologous bone marrow].

    Science.gov (United States)

    Liu, Hongwei; Sun, Junying; Wang, Yong; Yang, Xing; Zhu, Ershan

    2008-11-01

    To investigate the clinical application of grafting with bioactive glass (BG) and autologous bone marrow for defect after resection and curettage of benign bone neoplasm. From January 2004 to May 2007, 34 patients with bone defects were repaired. There were 21 males and 13 females with a mean age of 25.6 years (8 to 56 years). There were 14 cases of simple bone cysts, 6 cases of fibrous dysplasia, 3 cases of osteoid osteoma, 4 cases of non-ossifying fibroma, 2 cases of enchondroma and 3 cases of giant cell tumor of bone. Tumor sizes varied from 2.0 cm x 1.5 cm x 1.0 cm to 9.0 cm x 3.0 cm x 2.5 cm. Benign bone neoplasm was removed thoroughly with a curet or osteotome, bone defects ranged from 3.0 cm x 2.0 cm x 1.5 cm to 11.0 cm x 3.5 cm x 3.0 cm, which was closed-up with the mixtures of BG and autogenous red bone marrow. Six cases of pathologic fracture were fixed with steel plate or intramedullary nail. The postoperative systemic and local reactions were observed, and the regular X-ray examinations were performed to observe the bone healing. All the patients had good wound healing after operation. There was no yellow effusion nor white crystal and skin rash appeared around wound, indicating no allergic reaction occurred. A follow-up of 1 to 4 years (mean 24.6 months) showed satisfactory healing without complications. At averaged 16 weeks after operation, patients with bone tumor in lower limbs resumed walking independently and those with bone tumor in upper limbs resumed holding object. There was no tumor recurrence during follow-up. Radiographically, the interface between the implanted bone and host bone became fuzzy 1 month after implantation. Two months after operation, the BG was absorbed gradually, new bone formation could be seen in the defects. Four months after operation, implanted bone and host bone merged together, bone density increased. Six to ten months after operation, the majority of the implanted BG was absorbed and substituted for new bone, bone

  10. Effect of plate working length on plate stiffness and cyclic fatigue life in a cadaveric femoral fracture gap model stabilized with a 12-hole 2.4 mm locking compression plate.

    Science.gov (United States)

    Chao, Peini; Conrad, Bryan P; Lewis, Daniel D; Horodyski, MaryBeth; Pozzi, Antonio

    2013-06-24

    There are several factors that can affect the fatigue life of a bone plate, including the mechanical properties of the plate and the complexity of the fracture. The position of the screws can influence construct stiffness, plate strain and cyclic fatigue of the implants. Studies have not investigated these variables in implants utilized for long bone fracture fixation in dogs and cats. The purpose of the present study was to evaluate the effect of plate working length on construct stiffness, gap motion and resistance to cyclic fatigue of dog femora with a simulated fracture gap stabilized using a 12-hole 2.4 mm locking compression plates (LCP). Femora were plated with 12-hole 2.4 mm LCP using 2 screws per fracture segment (long working length group) or with 12-hole 2.4 mm LCP using 5 screws per fracture segment (a short working length group). Construct stiffness did not differ significantly between stabilization techniques. Implant failure did not occur in any of the plated femora during cycling. Mean ± SD yield load at failure in the short plate working length group was significantly higher than in the long plate working length group. In a femoral fracture gap model stabilized with a 2.4 mm LCP applied in contact with the bone, plate working length had no effect on stiffness, gap motion and resistance to fatigue. The short plate working length constructs failed at higher loads; however, yield loads for both the short and long plate working length constructs were within physiologic range.

  11. Three-dimensional microarchitecture of adolescent cancellous bone

    DEFF Research Database (Denmark)

    Ding, Ming; Danielsen, Carl Christian; Hvid, Ivan

    2012-01-01

    This study investigated microarchitectural, mechanical, collagen and mineral properties of normal adolescent cancellous bone, and compared them with adult and aging cancellous bone, to obtain more insight into the subchondral bone adaptations during development and growth. Twenty-three human...... proximal tibiae were harvested and divided into 3 groups according to their ages: adolescence (9 to 17years, n=6), young adult (18 to 24years, n=9), and adult (25 to 30years, n=8). Twelve cubic cancellous bone samples with dimensions of 8×8×8mm(3) were produced from each tibia, 6 from each medial......, the adolescent cancellous bone had similar bone volume fraction (BV/TV), structure type (plate, rod or mixtures), and connectivity (3-D trabecular networks) as the adult cancellous bone. The adolescent cancellous bone had significantly lower bone surface density (bone surface per total volume of specimen...

  12. Femoral fracture repair using a locking plate technique in an adult captive polar bear (Ursus maritimus).

    Science.gov (United States)

    Zimmerman, Dawn M; Dew, Terry; Douglass, Michael; Perez, Edward

    2010-02-01

    To report successful femoral fracture repair in a polar bear. Case report. Female polar bear (Ursus maritimus) 5 years and approximately 250 kg. A closed, complete, comminuted fracture of the distal midshaft femur was successfully reduced and stabilized using a compression plating technique with 2 specialized human femur plates offering axial, rotational, and bending support, and allowing the bone to share loads with the implant. Postoperative radiographs were obtained at 11.5 weeks, 11 months, and 24 months. Bone healing characterized by marked periosteal reaction was evident at 11 months with extensive remodeling evident at 24 months. No complications were noted. Distal mid shaft femoral fracture was reduced, stabilized, and healed in an adult polar bear with a locking plate technique using 2 plates. Previously, femoral fractures in polar bears were considered irreparable. Use of 2 plates applied with a locking plate technique can result in successful fracture repair despite large body weight and inability to restrict postoperative activity.

  13. Bone scintiscanning in metastases

    International Nuclear Information System (INIS)

    Cayla, J.; Basset, J.Y.

    1986-01-01

    The three fold interest of bone scintiscanning is discussed in relation to 182 cases of bone metastases of various origins. Firstly, this technic facilitates early diagnosis of invasion of the bone by the detection of metastatic lesions which, in 7.7% of cases are still infraradiologic, or even of reflex algodystrophy of the legs, which can be detected only from a scintiscan, long before X-ray plates can show the lumbar metastasis which is responsible. Secondly, the method is able to pick up more metastasic sites in 54.4% of cases than can be detected by X-ray; this is confirmed by investigation of the S/R ratio (ratio of the number of strongly binding sites to the number of sites showing radiologic damage) which is greater than unity for a considerable period. Thirdly, repeated scintiscanography provides a prognosis, because the survival time appears to be fairly closely correlated with the regression, stability or extension of strongly binding sites, although a ''flare phenomenon'' may give the erroneous impression that the metastatic process has deteriorated. Repeated scintiscanography also provides a good way of evaluating the efficacy of medical treatment, particularly in the case of bone metastases of mammary or prostatic origin. Sometimes, the decision for or against prophylactic or palliative orthopedic surgery may be based to a considerable extent on data provided by scintiscan [fr

  14. Bone scintiscanning in metastases

    Energy Technology Data Exchange (ETDEWEB)

    Cayla, J.; Basset, J.Y.

    1986-05-01

    The three fold interest of bone scintiscanning is discussed in relation to 182 cases of bone metastases of various origins. Firstly, this technic facilitates early diagnosis of invasion of the bone by the detection of metastatic lesions which, in 7.7% of cases are still infraradiologic, or even of reflex algodystrophy of the legs, which can be detected only from a scintiscan, long before X-ray plates can show the lumbar metastasis which is responsible. Secondly, the method is able to pick up more metastasic sites in 54.4% of cases than can be detected by X-ray; this is confirmed by investigation of the S/R ratio (ratio of the number of strongly binding sites to the number of sites showing radiologic damage) which is greater than unity for a considerable period. Thirdly, repeated scintiscanography provides a prognosis, because the survival time appears to be fairly closely correlated with the regression, stability or extension of strongly binding sites, although a ''flare phenomenon'' may give the erroneous impression that the metastatic process has deteriorated. Repeated scintiscanography also provides a good way of evaluating the efficacy of medical treatment, particularly in the case of bone metastases of mammary or prostatic origin. Sometimes, the decision for or against prophylactic or palliative orthopedic surgery may be based to a considerable extent on data provided by scintiscan.

  15. Quantitative computed tomography as a test of endurance for evaluation of bony plates

    International Nuclear Information System (INIS)

    Melo Filho, E.V.; Costa, L.A.V.S.; Oliveira, D.C.; Freitas, P.M.C.; Teixeira, M.W.; Costa, F.S.

    2012-01-01

    Quantitative computed tomography was used to determine the radiodensity of bony plates. The CT scans provided information regarding radiodensity of bony plates and allowed to verify the uniformity of bone mineral density in their scope. The proposed methodology should be considered as another tool for determining the resistance of these biomaterials. (author)

  16. Plate fixation of paediatric fractures of the distal tibia and fibula.

    Science.gov (United States)

    He, Bingshu; Wang, Jun

    2012-10-01

    The role of surgery in the management of paediatric long-bone shaft fractures remains a matter of debate. We present a series of paediatric patients with unstable fractures of the distal tibia and fibula, treated with titanium plate fixation. Excellent results were obtained after plate fixation.

  17. Study of a high gain microchannel plate photomultiplier having low statistical gain fluctuations

    International Nuclear Information System (INIS)

    Audier, M.

    1980-12-01

    A new photomultiplier configuration which synthesizes the performances of several models is proposed. The principles of microchannel plate photomultipliers are reviewed. The physical phenomena which limit the electron multiplication process in a microchannel and the detection efficiency of the microchannel plates are investigated. The operation of a herring-bone pattern device and of a system of two microchannel plate photomultipliers are described and characterized [fr

  18. Ex vivo biomechanical evaluation of pigeon (Columba livia) cadaver intact humeri and ostectomized humeri stabilized with caudally applied titanium locking plate or stainless steel nonlocking plate constructs.

    Science.gov (United States)

    Darrow, Brett G; Biskup, Jeffrey J; Weigel, Joseph P; Jones, Michael P; Xie, Xie; Liaw, Peter K; Tharpe, Josh L; Sharma, Aashish; Penumadu, Dayakar

    2017-05-01

    OBJECTIVE To evaluate mechanical properties of pigeon (Columba livia) cadaver intact humeri versus ostectomized humeri stabilized with a locking or nonlocking plate. SAMPLE 30 humeri from pigeon cadavers. PROCEDURES Specimens were allocated into 3 groups and tested in bending and torsion. Results for intact pigeon humeri were compared with results for ostectomized humeri repaired with a titanium 1.6-mm screw locking plate or a stainless steel 1.5-mm dynamic compression plate; the ostectomized humeri mimicked a fracture in a thin cortical bone. Locking plates were secured with locking screws (2 bicortical and 4 monocortical), and nonlocking plates were secured with bicortical nonlocking screws. Constructs were cyclically tested nondestructively in 4-point bending and then tested to failure in bending. A second set of constructs were cyclically tested non-destructively and then to failure in torsion. Stiffness, strength, and strain energy of each construct were compared. RESULTS Intact specimens were stiffer and stronger than the repair groups for all testing methods, except for nonlocking constructs, which were significantly stiffer than intact specimens under cyclic bending. Intact bones had significantly higher strain energies than locking plates in both bending and torsion. Locking and nonlocking plates were of equal strength and strain energy, but not stiffness, in bending and were of equal strength, stiffness, and strain energy in torsion. CONCLUSIONS AND CLINICAL RELEVANCE Results for this study suggested that increased torsional strength may be needed before bone plate repair can be considered as the sole fixation method for avian species.

  19. Cadmium plating replacements

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, M.J.; Groshart, E.C.

    1995-03-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  20. Bending and stretching of plates

    CERN Document Server

    Mansfield, E H; Hemp, W S

    1964-01-01

    The Bending and Stretching of Plates deals with elastic plate theory, particularly on small- and large-deflexion theory. Small-deflexion theory concerns derivation of basic equations, rectangular plates, plates of various shapes, plates whose boundaries are amenable to conformal transformation, plates with variable rigidity, and approximate methods. Large-deflexion theory includes general equations and some exact solutions, approximate methods in large-deflexion theory, asymptotic large-deflexion theories for very thin plates. Asymptotic theories covers membrane theory, tension field theory, a

  1. Screw Versus Plate Fixation for Chevron Osteotomy: A Retrospective Study.

    Science.gov (United States)

    Andrews, Boyd J; Fallat, Lawrence M; Kish, John P

    2016-01-01

    The chevron osteotomy is a popular procedure used for the correction of moderate hallux abducto valgus deformity. Fixation is typically accomplished with Kirschner wires or bone screws; however, in cystic or osteoporotic bone, these could be inadequate, resulting in displacement of the capital fragment. We propose using a locking plate and interfragmental screw for fixation of the chevron osteotomy that could reduce the healing time and decrease the incidence of displacement. We performed a retrospective cohort study for chevron osteotomies on 75 feet (73 patients). The control groups underwent fixation with 1 screw in 30 feet (40%) and 2 screws in 30 feet (40%). A total of 15 feet (20%) were included in the locking plate and interfragmental screw group. The patients were followed up until bone healing was achieved at a median of 7 (range 6 to 14) weeks. Our hypothesis was that those treated with the locking plate and interfragmental screw would have a faster healing time and fewer incidents of capital fragment displacement compared with the 1- or 2-screw groups. The corresponding mean intervals to healing for the 1-screw group was 7.71 ± 1.28 (range 6 to 10) weeks, for the 2-screw group was 7.27 ± 1.57 (range 6 to 14) weeks, and for the locking plate and interfragmental screw group was 7.01 ± 1.00 (range 6 to 9) weeks. One case of capital fragment displacement occurred in the single screw group and one in the 2-screw group. No displacement occurred in the locking plate and interfragmental screw group. Neither finding was statistically significant. However, we believe the locking plate and interfragmental screw could be a viable option in patients with osteoporotic and cystic bone changes for correction of hallux abducto valgus. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Use of a locking plate “notched head T-plate®” for the fixation of an ilial body fracture in a dog

    OpenAIRE

    Cassio Ricardo Auada Ferrigno; Paulo Vinícius Tertuliano Marinho; Márcio Poletto Ferreira; Jaqueline França dos Santos; Ísis dos Santos Dal-Bó; Fernanda Paes; Viviane Sanchez Galeazzi

    2016-01-01

    Several types of implants may be used to treat iliac fractures in dogs, of which osteosynthesis with plate is the most described and recommended in the literature. The type of plate and screw are major factors in osteosynthesis success. The use of locking plates has been advocated for this purpose, as they do not allow the plate-bone-screw unit to shift, providing angular stability and rigidity to the system. The present study aimed to describe the unprecedented use of a locking notched head ...

  3. An in vitro biomechanical comparison of dynamic condylar screw plate combined with a dorsal plate and double plate fixation of distal diaphyseal radial osteotomies in adult horses.

    Science.gov (United States)

    Janicek, John C; Wilson, David A; Carson, William L; Kramer, Joanne

    2009-08-01

    To compare stiffness and strength of a dynamic condylar screw plate combined with dorsal broad dynamic compression plate (DCS-bDCP) fixation with double broad dynamic compression plate (dbDCP) fixation used to repair oblique distal fractures of adult equine radii. Experimental. Adult equine radii (n=10 pair). An unconstrained three-dimensional loading-measurement system was used to determine stiffness of a 50 mm long intact, and then DCS-bDCP or dbDCP-plated osteotomized/ostectomized segment of radii when subjected to a nondestructive sequence of compression, torsion, and lateral-to-medial (LM), medial-to-lateral (ML), cranial-to-caudal (CrCa), and caudal-to-cranial (CaCr) bending. Uniform load over the entire length of construct identified its weakest characteristics during torsion and LM and CrCa bending to failure. No difference was observed between osteotomized/ostectomized DCS-bDCP and dbDCP construct stiffness for all 6 loading modes, and strength for all 3 failure loads. Ostectomized DCS-bDCP and dbDCP construct stiffness was significantly lower than osteotomized radii, the latter approaching intact for axial, LM, and CrCa bending. Most frequent failure was bone fracture through exit site of a screw located adjacent to osteotomy/ostectomy. DCS-DCP and dbDCP constructs had comparable strength and stiffness when repairing osteotomies/ostectomies in equine adult radius bone. Fracture reduction increased stiffness that approached intact bone for loads that placed the unplated side in compression. DCS-bDCP and dbDCP constructs are comparable in stiffness and strength when applied to oblique distal diaphyseal osteotomies/ostectomies in equine radius bone. However, the DCS's localized effect on distal epiphyseal structure because of additional bone removal remains to be investigated under in vivo articular loading conditions.

  4. In vivo analysis of biocompatibility and vascularization of the synthetic bone grafting substitute NanoBone.

    Science.gov (United States)

    Abshagen, K; Schrodi, I; Gerber, T; Vollmar, B

    2009-11-01

    One of the major challenges in the application of bone substitutes is adequate vascularization and biocompatibility of the implant. Thus, the temporal course of neovascularization and the microvascular inflammatory response of implants of NanoBone (fully synthetic nanocrystalline bone grafting material) were studied in vivo by using the mouse dorsal skinfold chamber model. Angiogenesis, microhemodynamics, and leukocyte-endothelial cell interaction were analyzed repetitively after implantation in the center and in the border zone of the implant up to 15 days. Both NanoBone granules and plates exhibited high biocompatibility comparable to that of cancellous bone, as indicated by a lack of venular leukocyte activation after implantation. In both synthetic NanoBone groups, signs of angiogenesis could be observed even at day 5 after implantation, whereas granules showed higher functional vessel density compared with NanoBone plates. The angiogenic response of the cancellous bone was markedly accelerated in the center of the implant tissue. Histologically, implant tissue showed an ingrowth of vascularized fibrous tissue into the material combined with an increased number of foreign-body giant cells. In conclusion, NanoBone, particularly in granular form, showed high biocompatibility and high angiogenic response, thus improving the healing of bone defects. Our results underline that, beside the composition and nanostructure, the macrostructure is also of importance for the incorporation of the biomaterial by the host tissue. (c) 2008 Wiley Periodicals, Inc.

  5. Plating on Zircaloy-2

    International Nuclear Information System (INIS)

    Dini, J.W.; Johnson, H.R.; Jones, A.

    1979-03-01

    Zircaloy-2 is a difficult alloy to coat with an adherent electroplate because it easily forms a tenacious oxide film in air and aqueous solutions. Procedures reported in the literature and those developed at SLL for surmounting this problem were investigated. The best results were obtained when specimens were first etched in either an ammonium bifluoride/sulfuric acid or an ammonium bifluoride solution, plated, and then heated at 700 0 C for 1 hour in a constrained condition. Machining threads in the Zircaloy-2 for the purpose of providing sites for mechanical interlocking of the plating also proved satisfactory

  6. NICKEL PLATING PROCESS

    Science.gov (United States)

    Hoover, T.B.; Zava, T.E.

    1959-05-12

    A simplified process is presented for plating nickel by the vapor decomposition of nickel carbonyl. In a preferred form of the invention a solid surface is nickel plated by subjecting the surface to contact with a mixture containing by volume approximately 20% nickel carbonyl vapor, 2% hydrogen sulfide and .l% water vapor or 1% oxygen and the remainder carbon dioxide at room temperature until the desired thickness of nickel is obtained. The advantage of this composition over others is that the normally explosive nickel carbonyl is greatly stabilized.

  7. OPENING STRUCTURE OF THE BONE BASIN ON SOUTH SULAWESI IN RELATION TO PROCESS OF SEDIMENTATION

    Directory of Open Access Journals (Sweden)

    Lili Sarmili

    2017-07-01

    Full Text Available Sulawesi Island is situated on the three major plates, namely the Indo-Australian plate together with Continent Australia (Australian Craton plate moves towards the North - Northeast and crust Pacific - Philippines moves towards the West - Northwest, causing the collision with the Eurasian plate (Sunda Land which more passive or stable. The Bone basin is located between South Sulawesi and Southeast Sulawesi arms. This basin is formed by several fault system, such as, Walanae, Palukoro, West and East Bone faults and others. Several active faults are likely to be extended each other into the openings structure and characterized by the accumulation of young sediment in the Bone basin.

  8. In vitro simulation of pathological bone conditions to predict clinical outcome of bone tissue engineered materials

    Science.gov (United States)

    Nguyen, Duong Thuy Thi

    According to the Centers for Disease Control, the geriatric population of ≥65 years of age will increase to 51.5 million in 2020; 40% of white women and 13% of white men will be at risk for fragility fractures or fractures sustained under normal stress and loading conditions due to bone disease, leading to hospitalization and surgical treatment. Fracture management strategies can be divided into pharmaceutical therapy, surgical intervention, and tissue regeneration for fracture prevention, fracture stabilization, and fracture site regeneration, respectively. However, these strategies fail to accommodate the pathological nature of fragility fractures, leading to unwanted side effects, implant failures, and non-unions. Compromised innate bone healing reactions of patients with bone diseases are exacerbated with protective bone therapy. Once these patients sustain a fracture, bone healing is a challenge, especially when fracture stabilization is unsuccessful. Traditional stabilizing screw and plate systems were designed with emphasis on bone mechanics rather than biology. Bone grafts are often used with fixation devices to provide skeletal continuity at the fracture gap. Current bone grafts include autologous bone tissue and donor bone tissue; however, the quality and quantity demanded by fragility fractures sustained by high-risk geriatric patients and patients with bone diseases are not met. Consequently, bone tissue engineering strategies are advancing towards functionalized bone substitutes to provide fracture reconstruction while effectively mediating bone healing in normal and diseased fracture environments. In order to target fragility fractures, fracture management strategies should be tailored to allow bone regeneration and fracture stabilization with bioactive bone substitutes designed for the pathological environment. The clinical outcome of these materials must be predictable within various disease environments. Initial development of a targeted

  9. Coronal CT imaging of the extremity growth plate

    International Nuclear Information System (INIS)

    Murray, K.; Nixon, G.W.

    1986-01-01

    Coronal CT imaging has been used to evaluate the growth plate region of long bones. Proper patient positioning facilitates coronal imaging and is easily achieved in most instances. Studied were neoplasms, instances of partial growth arrest, and loose bodies. In the evaluation of neoplasms and neoplasia, coronal sections are most useful in determining the longitudinal extent of disease and involvement of the growth plate and epiphysis. This information is useful in diagnosis and is of critical importance in operative planning. Coronal CT imaging also allows determination of the location and extent of involvement of partial growth plate arrest after physeal injury. This method of growth plate mapping gives information superior to the obtained from conventional or reconstructed CT images

  10. Nuclear reactor alignment plate configuration

    Energy Technology Data Exchange (ETDEWEB)

    Altman, David A; Forsyth, David R; Smith, Richard E; Singleton, Norman R

    2014-01-28

    An alignment plate that is attached to a core barrel of a pressurized water reactor and fits within slots within a top plate of a lower core shroud and upper core plate to maintain lateral alignment of the reactor internals. The alignment plate is connected to the core barrel through two vertically-spaced dowel pins that extend from the outside surface of the core barrel through a reinforcement pad and into corresponding holes in the alignment plate. Additionally, threaded fasteners are inserted around the perimeter of the reinforcement pad and into the alignment plate to further secure the alignment plate to the core barrel. A fillet weld also is deposited around the perimeter of the reinforcement pad. To accomodate thermal growth between the alignment plate and the core barrel, a gap is left above, below and at both sides of one of the dowel pins in the alignment plate holes through with the dowel pins pass.

  11. Create Your Plate

    Medline Plus

    Full Text Available ... 1 Type 2 About Us Online Community Meal Planning Sign In Search: Search More Sites Search ≡ Are ... Fitness Home Food MyFoodAdvisor Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten ...

  12. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy Foods donate en -- A Future Without Diabetes - a-future-without-diabetes-2.html A Future Without Diabetes Donate towards research today and your gift will be matched. Donate ...

  13. The Plate Tectonics Project

    Science.gov (United States)

    Hein, Annamae J.

    2011-01-01

    The Plate Tectonics Project is a multiday, inquiry-based unit that facilitates students as self-motivated learners. Reliable Web sites are offered to assist with lessons, and a summative rubric is used to facilitate the holistic nature of the project. After each topic (parts of the Earth, continental drift, etc.) is covered, the students will…

  14. Create Your Plate

    Medline Plus

    Full Text Available ... meal-planning, . In this section Food Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy Foods donate en -- A Future Without Diabetes - a-future-without-diabetes-1.html A Future ...

  15. Create Your Plate

    Medline Plus

    Full Text Available ... Types of Activity Weight Loss Assess Your Lifestyle Getting Started Food Choices In My Community Home Find Your ... but changes the portion sizes so you are getting larger portions of ... seven steps to get started: Using your dinner plate, put a line down ...

  16. Create Your Plate

    Medline Plus

    Full Text Available ... Create Your Plate is a simple and effective way to manage your blood glucose levels and lose weight. With ... for Donations - ways-to-give-201710-hotelscom.html Ways to Give ... to help prevent and manage diabetes. Ask the Experts: Learn to Live Well ...

  17. Create Your Plate

    Medline Plus

    Full Text Available ... meal-planning, . In this section Food Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy Foods donate en -- A Future Without Diabetes - a-future-without-diabetes-2.html A Future ...

  18. Create Your Plate

    Medline Plus

    Full Text Available ... Type 1 Type 2 About Us Online Community Meal Planning Sign In Search: Search More Sites Search ≡ ... Home Food MyFoodAdvisor Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free ...

  19. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy Foods donate en -- A Future Without Diabetes - a-future-without-diabetes.html A Future Without Diabetes Donate towards research today and your gift will be matched. Donate Today We Can Help - we- ...

  20. Create Your Plate

    Medline Plus

    Full Text Available ... tax-deductible gift today can fund critical diabetes research and support vital diabetes education services that improve the ... way to manage your blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ...

  1. Plate girders under bending

    NARCIS (Netherlands)

    Abspoel, R.; Dubina, D.; Ungureanu, V.

    2016-01-01

    In a material economy driven plate girder design, the lever arm between the flanges will increase. This leads to higher stiffness and bending moment resistance, but also to an in-crease of the web slenderness. This means that high strength steels can be used leading to a large reduction of the steel

  2. Broken bone

    Science.gov (United States)

    ... Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Broken bone URL of this page: //medlineplus.gov/ency/ ... following steps to reduce your risk of a broken bone: Wear protective ... pads. Create a safe home for young children. Place a gate at stairways ...

  3. Placement of Plantar Plates for Lapidus Arthrodesis: Anatomical Considerations.

    Science.gov (United States)

    Plaass, Christian; Claassen, Leif; Daniilidis, Kiriakos; Fumy, Mariesol; Stukenborg-Colsman, Christina; Schmiedl, Andreas; Ettinger, Sarah

    2016-04-01

    The modified Lapidus procedure is an accepted treatment option for patients with moderate to severe hallux valgus. Placing a plate plantar on the tension side of the arthrodesis has been shown to be biomechanically superior and has provided good clinical results. There is some concern about interference of the plantar placed plates on the tendon insertions. The purpose of this study was to determine a "safe zone" for plantar plate placement without irritation of the tendons. Twenty-nine embalmed right feet were used for this study. The anatomy of the insertion of the peroneus longus (PL) tendon and tibialis anterior (TA) tendon on the medial cuneiform and first metatarsal were analyzed. Six different plate designs for plantar plating of the first tarsometatarsal fusion were included. The fit to the bone and contact to tendon insertion were analyzed. The PL showed a main insertion to the first metatarsal and a lesser insertion to the medial cuneiform. The TA inserted onto the medial cuneiform and first metatarsal in all cases in our series. There was a "safe zone" between the TA and PL insertion areas for plate placement. Straight, Y- and U-shaped plates could be placed without compromising the tendon insertion. Depending on the design, even preshaped plates may have to be bent to allow a good fit to the plantar side of the first tarsometatarsal joint. Plantar plating for modified Lapidus arthrodesis can be safely performed, without damaging the plantar tendon insertion area of the PL and TA. The exact knowledge of the anatomy of the plantar region of the tarsometatarsal joint can help to improve plate placement. © The Author(s) 2015.

  4. Fabrication of mandible fracture plate by indirect additive manufacturing

    Science.gov (United States)

    Aizat, M.; Khan, S. F.

    2017-10-01

    Bone fracture is a serious skeletal injury due to accidents and fragility of the bones at a certain age. In order to accelerate fracture healing process, fracture bone plate is use to hold the fracture segment for more stability. The purpose of this study is to fabricate mandibular fracture plate by using indirect additive manufacturing methods in order to reduce time taken during bending and shaping the fracture fixation plate that conform to the anatomy of the fractured bone site. The design and analysis of the plates are performed using CATIA and ANSYS software. The 3D-CAD data were sent to an additive manufacturing machine (fused filament fabricated) to generate master pattern using PLA and the mould were fabricated using Plaster of Paris. A melt ZAMAK 3 was poured directly into the moulds, and left it until completely harden. 3point bending test was performed on the prototype plate using universal testing machine. Stress-strain curve shows the graph exhibited a linear relationship of stress-strain up to a strain value of 0.001. Specimens give a maximum yielding stress and then break before the conventional deflection. Since the maximum flexural stress and the breaking stress are far apart with a plateau stating at strain value of 0.003mm/mm in most specimens, the specimen’s failure types are considered plastic failure mode. The average thickness and width are 1.65mm and 2.18mm respectively. The flexural modulus and flexural strength are 189.5GPa and 518.1MPa, respectively.

  5. The Evaluation of Epiphyseal Plate Histological Changes in Osteopetrotic op/op Mice.

    Directory of Open Access Journals (Sweden)

    Aligholi Sobhani

    2003-09-01

    Full Text Available This study was designed for evaluation of epiphyseal plate histological changes of femur bones in osteopetrotic op/op mice.In this study 5 osteopetrotic op/op mice which were purchased from the commercial source were used.The animals were killed by overdose of chloroform and their femur bones were extracted. The bones were fixed in 10% formaldehyde and decalcified by HCl (0.6N, and routine histological processing were performed. The sections were stained by H&E methods and studied by conventional light microscopy. The results showed that, proliferative zone (PZ and especially hypertrophic zone (HZ were much thickened. In the ossification zone, trabecular bones were irregular and atypical osteoblast cells were observed. The osteoclast cells were not attached to trabecular bones. The bone marrow cavity was restricted and bone marrow cells were poor and scattered. Findings of the present investigation are similar to those reported about epiphyseal plate in osteosclerotic (OC mice in which epiphyseal plate especially hypertrophic zone was thickened and chondrocytes were not substituted for osteoblasts in calcified cartilage area. Also, osteoclast cells had been inactive or absent in OC mice. For prevention of other complication due to the epiphyseal plate changes in new borne, suitable and punctually treatment protocols such as prescription of Macrophage Colony Stimulating-Factor (MCS-F could be useful.

  6. Effect of plate shapes in orifice plate type flowmeters

    International Nuclear Information System (INIS)

    Moeller, S.V.

    1984-01-01

    The study of unusual plate shapes in orifice plate type flowmeters is presented, with a view to providing data for the substitution of the plate with one centered circular orifice in those applications where its use is not possible. For this purpose, six pairs of plates with different forms, with and without chamfered edges, were made and tested in a closed water loop. Results show that, generally, the use of chamfers improves the results and, in the case of perforated and slotlike orificed plates, the narrow-ness of the fluid passage tends to make unnecessary its use. (Author) [pt

  7. Bone Scan

    Science.gov (United States)

    ... posts Join Mayo Clinic Connect Bone scan About Advertisement Mayo Clinic does not endorse companies or products. ... a Job Site Map About This Site Twitter Facebook Google YouTube Pinterest Mayo Clinic is a not- ...

  8. Bone Biopsy

    Science.gov (United States)

    ... bear denotes child-specific content. Related Articles and Media Computed Tomography (CT) - Body Magnetic Resonance Imaging (MRI) - Body X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Bone Biopsy Sponsored by Please note ...

  9. Bone sarcomas

    International Nuclear Information System (INIS)

    Mudry, P.

    2008-01-01

    Bone sarcomas are malignancies with peak incidence in adolescents and young adults. The most frequent are osteosarcoma and Ewing sarcoma/PNET, in an older adults are seen chondrosarcomas, other ones are rare. In general, biology of sarcomas is closely related to pediatric malignancies with fast growth, local aggressiveness, tendency to early hematogenic dissemination and chemo sensitivity. Diagnostics and treatment of bone sarcomas should be done in well experienced centres due to low incidence and broad issue of this topic. An interdisciplinary approach and staff education is essential in due care of patients with bone sarcoma. If these criteria are achieved, the cure rate is contemporary at 65 - 70 %, while some subpopulation of patients has chance for cure up to 90 %. Osteosarcoma and Ewing sarcoma/PNET are discussed below as types of most frequent bone sarcoma. (author)

  10. Bone pain

    DEFF Research Database (Denmark)

    Frost, Charlotte Ørsted; Hansen, Rikke Rie; Heegaard, Anne-Marie

    2016-01-01

    Skeletal conditions are common causes of chronic pain and there is an unmet medical need for improved treatment options. Bone pain is currently managed with disease modifying agents and/or analgesics depending on the condition. Disease modifying agents affect the underlying pathophysiology...... of the disease and reduce as a secondary effect bone pain. Antiresorptive and anabolic agents, such as bisphosphonates and intermittent parathyroid hormone (1-34), respectively, have proven effective as pain relieving agents. Cathepsin K inhibitors and anti-sclerostin antibodies hold, due to their disease...... modifying effects, promise of a pain relieving effect. NSAIDs and opioids are widely employed in the treatment of bone pain. However, recent preclinical findings demonstrating a unique neuronal innervation of bone tissue and sprouting of sensory nerve fibers open for new treatment possibilities....

  11. A STUDY ON PROXIMAL HUMERAL FRACTURES STABILISED WITH PHILOS PLATE

    Directory of Open Access Journals (Sweden)

    Praveen Sivakumar K

    2017-02-01

    Full Text Available BACKGROUND Techniques for treating complex proximal humeral fractures vary and include fixations using tension bands, percutaneous pins, bone suture, T-plates, intramedullary nails, double tubular plates, hemiarthroplasty, plant tan humerus fixator plates, Polaris nails and blade plates. Complications of these techniques include cutout or back out of the screws and plates, avascular necrosis, nonunion, malunion, nail migration, rotator cuff impairment and impingement syndromes. Insufficient anchorage from conventional implants may lead to early loosening and failure, especially in osteoporotic bones. In general, nonoperative treatment of displaced three and four-part fractures of the proximal humerus leads to poor outcome due to intraarticular nature of injury and inherent instability of the fragments. Comminuted fractures of the proximal humerus are at risk of fixation failure, screw loosening and fracture displacement. Open reduction and internal fixation with conventional plate and screws has been associated with unacceptably high incidence of screw pull out. PHILOS (the proximal humeral internal locking system plate is an internal fixation system that enables angled stabilisation with multiple interlocking screws for fractures of the proximal humerus. MATERIALS AND METHODS 30 patients with proximal humerus fractures who were admitted in the Department of Orthopaedics, Government General Hospital, Kakinada, during the period November 2014 - November 2016 were taken up for study according to inclusion criteria. All patients were treated with PHILOS plate. These proximal humerus fractures were classified according to Neer’s classification. Patients were followed up at 6 weeks, 12 weeks and 6 months’ interval. Functional outcomes for pain, range of motion and muscle power and function were assessed using the Constant-Murley scoring system. Collected data analysed with independent t-test and ANNOVA test. RESULTS The outcome of the study was 1

  12. Anterior double plating for rigid fixation of isolated tibiotalar arthrodesis.

    Science.gov (United States)

    Plaass, Christian; Knupp, Markus; Barg, Alexej; Hintermann, Beat

    2009-07-01

    Arthrodesis is the most common procedure used to treat end-stage osteoarthritis of the ankle, particularly in patients with difficult conditions such as poor bone quality. While many techniques are available to fuse the ankle, current recommendations favor the use of internal fixation with screws and/or plates. Despite of progress, the complication rate remains a major concern. Non-union is one difficult problem especially with difficult bone conditions, particularly the loss of bone stock on the talar side. Therefore, fusion of the tibiotalar joint is often extended to the talocalcaneal joint to provide sufficient stability. To preserve the subtalar joint, an anterior double plate system for rigid fixation of isolated tibiotalar arthrodesis was developed. This is a preliminary report on the clinical and radiological outcome with this technique. Twenty-nine patients (15 men, 14 women; one ankle per patient) were treated from October 2006 to September 2007. We converted 16 ankles with osteoarthritis and difficult bone conditions, four non-united ankle arthrodeses, and nine failed total ankle replacements to an isolated tibiotalar arthrodesis using anterior double plating. If necessary, we used solid allograft to fill bony defects. Outcomes included bone union as assessed by radiographs, pain as indicated by the American Orthopaedic Foot and Ankle Society scores, and patient satisfaction. Solid arthrodesis was achieved after an average of 12.3 (eight to 26) weeks in the 16 ankles without bone graft interposed between the tibia and talus, and 14.3 (range, 8 to 26) weeks in the 13 ankles with interpositional bone allograft. Radiographs showed that the position of arthrodesis obtained at the time of surgery did not change in any patient up to one year after surgery. The mean American Orthopaedic Foot and Ankle Society (AOFAS) Hindfoot Score increased from 37 (range, 20 to 63) preoperatively to 68 (range, 50 to 92) at the last followup. Twenty-seven patients (93%) were

  13. A biomechanical comparison of conventional dynamic compression plates and string-of-pearls™ locking plates using cantilever bending in a canine Ilial fracture model.

    Science.gov (United States)

    Kenzig, Allison R; Butler, James R; Priddy, Lauren B; Lacy, Kristen R; Elder, Steven H

    2017-07-13

    Fracture of the ilium is common orthopedic injury that often requires surgical stabilization in canine patients. Of the various methods of surgical stabilization available, application of a lateral bone plate to the ilium is the most common method of fixation. Many plating options are available, each having its own advantages and disadvantages. The purpose of this study was to evaluate the biomechanical properties of a 3.5 mm String-of-Pearls™ plate and a 3.5 mm dynamic compression plate in a cadaveric canine ilial fracture model. Hemipelves were tested in cantilever bending to failure and construct stiffness, yield load, displacement at yield, ultimate load, and mode of failure were compared. The mean stiffness of dynamic compression plate (116 ± 47 N/mm) and String-of-Pearls™ plate (107 ± 18 N/mm) constructs, mean yield load of dynamic compression plate (793 ± 333 N) and String-of-Pearls™ plate (860 ± 207 N) constructs, mean displacement at yield of dynamic compression plate (8.6 ± 3.0 mm) and String-of-Pearls™ plate (10.2 ± 2.8 mm) constructs, and ultimate load at failure of dynamic compression plate (936 ± 320 N) and String-of-Pearls™ plate (939 ± 191 N) constructs were not significantly different. No differences were found between constructs with respect to mode of failure. No significant biomechanical differences were found between String-of-Pearls™ plate and dynamic compression plate constructs in this simplified cadaveric canine ilial fracture model.

  14. Fuel cell end plate structure

    Science.gov (United States)

    Guthrie, Robin J.; Katz, Murray; Schroll, Craig R.

    1991-04-23

    The end plates (16) of a fuel cell stack (12) are formed of a thin membrane. Pressure plates (20) exert compressive load through insulation layers (22, 26) to the membrane. Electrical contact between the end plates (16) and electrodes (50, 58) is maintained without deleterious making and breaking of electrical contacts during thermal transients. The thin end plate (16) under compressive load will not distort with a temperature difference across its thickness. Pressure plate (20) experiences a low thermal transient because it is insulated from the cell. The impact on the end plate of any slight deflection created in the pressure plate by temperature difference is minimized by the resilient pressure pad, in the form of insulation, therebetween.

  15. Surface functionalization of tissue culture polystyrene plates with hydroxyapatite under body fluid conditions and its effect on differentiation behaviors of mesenchymal stem cells.

    Science.gov (United States)

    Iijima, Kazutoshi; Suzuki, Ryo; Iizuka, Ayako; Ueno-Yokohata, Hitomi; Kiyokawa, Nobutaka; Hashizume, Mineo

    2016-11-01

    The surfaces of polystyrene (PS) cell culture plates were functionalized with hydroxyapatite (HAp) under body fluid conditions utilizing protein adsorption layers and a pretreatment with an alternate soaking process (ASP) using solutions containing calcium and phosphate ions. Adsorption layers of human serum albumin (HSA) formed on the surface of each well of commercial 24-well PS plates by solution processes. CaCl2 and K2HPO4 solutions were alternately added to the wells, the plates were incubated to form the precursors, and this was followed by the addition of simulated body fluid (SBF) and a further incubation for 24h. These treatments resulted in the surfaces of the PS cell culture plates being completely covered with bone-like HAp. The coating of PS plates with HAp promoted the adhesion of mesenchymal stem cells (MSCs) and maintained cell growth that was as fast as that on tissue culture-treated PS (TCPS) plates. Osteogenic differentiation was greater, whereas adipogenic and chondrogenic differentiation was less in the culture on HAp-coated PS plates than in that on TCPS plates. The present method is useful for preparing HAp-coated PS plates at clean benches without the need for any expensive apparatus. HAp coated on PS plates by this method was a bone-like apatite with high bioactivity; therefore, the present HAp-coated PS plates are promising materials for assays of bone-related cells in the bone remodeling process. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Medicines and Bone Loss

    Science.gov (United States)

    Fact Sheet Medici a ne n s d Bone Loss Some types of medicines can cause bone loss, making your bones weak, if used for a long time. Use over a short time ... old bone and replaces it with new bone. Bone loss occurs when old bone breaks down faster than ...

  17. Plate Full of Color

    Centers for Disease Control (CDC) Podcasts

    2008-08-04

    The Eagle Books are a series of four books that are brought to life by wise animal characters - Mr. Eagle, Miss Rabbit, and Coyote - who engage Rain That Dances and his young friends in the joy of physical activity, eating healthy foods, and learning from their elders about health and diabetes prevention. Plate Full of Color teaches the value of eating a variety of colorful and healthy foods.  Created: 8/4/2008 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 8/5/2008.

  18. Concave microwell plate facilitates chondrogenesis from mesenchymal stem cells.

    Science.gov (United States)

    Ko, Ji-Yun; Im, Gun-Il

    2016-11-01

    To compare in vitro chondrogenesis from bone marrow-derived mesenchymal stem cells using concave microwell plates with those obtained using culture tubes. Pellets cultured in concave microwell plates had a significantly higher level of GAG per DNA content and greater proteoglycan content than those cultured in tubes at day 7 and 14. Three chondrogenic markers, SOX-9, COL2A1 and aggrecan, showed significantly higher expression in pellets cultured in concave microwell plates than those cultured in tubes at day 7 and 14. At day 21, there was not a significant difference in the expression of these markers. COL10A1, the typical hypertrophy marker, was significantly lower in concave microwell plates during the whole culture period. Runx-2, a marker of hypertrophy and osteogenesis, was significantly lower at day 7 in pellets cultured in concave microwell plates than those cultured in tubes. Concave microwell plates provide a convenient and effective tool for the study of in vitro chondrogenesis and may replace the use of propylene culture tube.

  19. A novel osteosynthesis plate design for routine corrective facial surgery.

    Science.gov (United States)

    Mommaerts, Maurice Y

    2002-07-01

    Plating systems for the osteosynthesis of facial osteotomies have different requirements to those used to treat facial fractures. The aim of fracture treatment is anatomical fragment reduction, functional/rigid immobilization, restoration of occlusion and aesthetics, and occasionally defect bridging. In corrective facial surgery however there is a need for intra-operative adjustments related to changes in occlusion and aesthetics, and defect bridging occurs frequently. Postoperatively, training elastics are used to control temporary neuromuscular imbalance. To accommodate these demands a new plating system is presented, based on five requisites: allowance of occlusal and aesthetic adjustment without hardware removal, plate dimensions that accommodate routine skeletal repositionings, reduced hardware volume compared with trauma plating systems, screws that fit the inter-dental spaces when tension banding, and capability for micro-screw fixation of bone grafts in the osteotomy site. The files of 1000 non-congenital facial deformity patients were analyzed. The sagittal, vertical and transverse movements were drawn and the bridging distances calculated. Slotted plates with double-armed interconnections were designed for maxillary, zygomatic-sandwich, chin and segmental osteotomies. A separate design was made for the sagittal split plate. A pilot study was performed using 20 patients. The system showed great versatility and adaptability, but a multicenter morbidity study is necessary, mainly to study postoperative stability.

  20. Closed External Fixation for Failing or Failed Femoral Shaft Plating in a Developing Country.

    Science.gov (United States)

    Aliakbar, Adil; Witwit, Ibrahim; Al-Algawy, Alaa A Hussein

    2017-08-01

    Femoral shaft fractures are one of the common injuries that is treated by open reduction, with internal fixation by plate and screws or intramedullary nailing, which can achieve a high union rate. To evaluate the outcome of using closed external fixation to augment a failing plate; with signs of screw loosening and increasing bone/plate gap; a failed plate; broken plate; screws completely out of bone with redisplacement of fracture. A retrospective study on 18 patients, aged between 17-42 years, who presented between 6-18 weeks after initial surgical fixation, with pain, difficulty in limb function, deformity and abnormal movement at fracture site, was done. X-Rays showed plating failure with acceptable amount of callus, which unfortunately had refractured. Cases associated with infection and no radiological evidence of callus formation were excluded from this study. Closed reduction was done by manipulation, then fracture fixation by AO external fixator. The patients were encouraged for full weight bearing as early as possible with dynamization later on. Of the 18 patients who underwent external fixation after close reduction, 15 cases showed bone healing in a period between 11-18 weeks (mean of 14.27 weeks) with good alignment (Radiologically). Removal of external fixator was done followed by physical therapy thereafter. Closed external fixation for treatment of failing or failed femoral plating, achieves good success rate and has less complications, is a short time procedure, especially in a hospital with limited resources.

  1. Morphologic and radiologic data of isolated vertebral end-plates under particular consideration of radiodensitometry

    International Nuclear Information System (INIS)

    Unflath, U.

    1979-01-01

    The intention was to find examination techniques for macroscopico-morphological diagnosis, for quantification of the concavity and methods for roentgenologico-densitometric analysis of vertebral end-plates. The following factors were used for macromorphologic diagnosis: osteophytes, ridge constitution, ridge transition, cribriform plate and concavity. The radiodensitometric analysis comprised investigation of bone density, anisotropy and ridge mineralisation. The specimen were radiographed on a mammograph together with calcium chloride solutions of increasing concentration. Statistically significant differences in the behaviour of basal and upper plates were not observed. With reference to the factors osteophytes and ridge constitution the basal plates seem to be morphologically more variable than the upper plates. It resulted that the features absolute concavity and concavity quotient are highly appropriate factors to document the constitution of the isolated vertebral end-plates. Also the features density, anisotropy and ridge mineralisation were found to be useful for documentation. The result of data correlation was that high concavity quotients are accompanied by macroscopically medium- to small-sized pores. Density and anisotropy of the overall profiles do not show correlation, but voluminous cribriform laminae tend to develop more inhomogenic structures. As to be expected, bone density increases with macroscopic fine porosity. The higher the concavity quotient is, the smaller are the values for density, ridge mineralisation and anisotropy. Thus a high degree of vertebral end-plate concavity indicates reduced bone density and lower mineral content. (orig./MG) [de

  2. CMS Resistive plate Champers

    CERN Document Server

    Zainab, Karam

    2013-01-01

    There are many types of gas detectors which are used in CERN in LHC project, There is a main parts for the gas detectors which must be in all gas detectors types like Multiwire proportional chambers, such as the micromesh gaseous structure chamber (the MicroMegas), Gas-electron multiplier (GEM) detector, Resistive Plate Champers... Compact Muon Solenoid (CMS) experiment detecting muons which are powerful tool for recognizing signatures of interesting physics processes. The CMS detector uses: drift tube (DT), cathode strip chamber (CSC) and resistive plate chamber (RPC). Building RPC’s was my project in summer student program (hardware). RPC’s have advantages which are triggering detector and Excellent time resolution which reinforce the measurement of the correct beam crossing time. RPC’s Organized in stations :  RPC barrel (RB) there are 4 stations, namely RB1, RB2, RB3, and RB4  While in the RPC endcap (RE) the 3 stations are RE1, RE2, and RE3. In the endcaps a new starion will be added and this...

  3. Plate fixation in periprosthetic femur fractures Vancouver type B1-Trochanteric hook plate or subtrochanterical bicortical locking?

    Science.gov (United States)

    Lenz, Mark; Stoffel, Karl; Kielstein, Heike; Mayo, Keith; Hofmann, Gunther O; Gueorguiev, Boyko

    2016-12-01

    Proximal plate fixation in periprosthetic femur fractures can be improved by plate anchorage in the greater trochanter (lateral tension band principle) or bicortical locking screw placement beside the prosthesis stem in an embracement configuration. Both concepts were compared in a biomechanical test using a femoral hook plate (hook) or a locking attachment plate (LAP). After bone mineral density (BMD) measurement in the greater trochanter, six pairs of fresh frozen human femora were assigned to two groups and instrumented with cemented hip endoprostheses. A transverse osteotomy was set distal to the tip of the prosthesis, simulating a Vancouver B1 fracture. Each pair was instrumented using a plate tensioner with either hook or LAP construct. Cyclic testing (2Hz) with physiologic profile and monotonically increasing load was performed until catastrophic failure. Plate stiffness was compared in a four-point-bending-test. Paired student's-t-test was used for statistical evaluation (pTrochanteric fixation is highly BMD dependent and may be restricted to major greater trochanteric involvement requiring stabilization. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Effect of anisotropy on stress-induced electrical potentials in bovine bone using ultrasound irradiation

    Science.gov (United States)

    Matsukawa, S.; Makino, T.; Mori, S.; Koyama, D.; Takayanagi, S.; Mizuno, K.; Yanagitani, T.; Matsukawa, M.

    2017-04-01

    The bone fracture healing mechanism of the low-intensity pulsed ultrasound technique is not yet clearly understood. In our previous study, the electrical potentials induced in bone were successfully measured by focusing on piezoelectricity in the MHz range. Bone is composed of collagen and hydroxyapatite and has strong anisotropy. The purpose of this study is to investigate the effects of bone anisotropy on the electrical potentials induced by ultrasound irradiation. For this study, ultrasound bone transducers were fabricated using cortical bovine bone plates as piezoelectric devices. An ultrasound of 7.4 kPapeak-peak (i.e., the peak-to-peak pressure value) was used to irradiate the side surface of each bone plate. Electrical potentials induced in the bone plate were then measured by varying the wave propagation direction in the plate. The peak-to-peak values of these ultrasonically induced electrical potentials were found to vary with changes in the ultrasound propagation direction in the bone sample. The potential was maximized at an inclination of approximately 45° to the bone axis but was minimized around the three orthogonal directions. These maxima and minima ranged from 28 to 33 μVpeak-peak and from 5 to 12 μVpeak-peak, respectively. Additionally, our ultrasound results indicated a change in polarity due to bone anisotropy in the MHz range.

  5. Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis.

    Science.gov (United States)

    Kandemir, Utku; Augat, Peter; Konowalczyk, Stefanie; Wipf, Felix; von Oldenburg, Geert; Schmidt, Ulf

    2017-08-01

    To investigate whether (1) the type of fixation at the shaft (hybrid vs. locking), (2) the position of the plate (offset vs. contact) and (3) the implant material has a significant effect on (a) construct stiffness and (b) fatigue life in a distal femur extraarticular comminuted fracture model using the same design of distal femur periarticular locking plate. An extraarticular severely comminuted distal femoral fracture pattern (OTA/AO 33-A3) was simulated using artificial bone substitutes. Ten-hole distal lateral femur locking plates were used for fixation per the recommended surgical technique. At the distal metaphyseal fragment, all possible locking screws were placed. For the proximal diaphyseal fragment, different types of screws were used to create 4 different fixation constructs: (1) stainless steel hybrid (SSH), (2) stainless steel locked (SSL), (3) titanium locked (TiL), and (4) stainless steel locked with 5-mm offset at the diaphysis (SSLO). Six specimens of each construct configuration were tested. First, each specimen was nondestructively loaded axially to determine the stiffness. Then, each specimen was cyclically loaded with increasing load levels until failure. Construct Stiffness: The fixation construct with a stainless steel plate and hybrid fixation (SSH) had the highest stiffness followed by the construct with a stainless steel plate and locking screws (SSL) and were not statistically different from each other. Offset placement (SSLO) and using a titanium implant (TiL) significantly reduced construct stiffness. Fatigue Failure: The stainless steel with hybrid fixation group (SSH) withstood the most number of cycles to failure and higher loads, followed by the stainless steel plate and locking screw group (SSL), stainless steel plate with locking screws and offset group (SSLO), and the titanium plate and locking screws group (TiL) consecutively. Offset placement (SSLO) as well as using a titanium implant (TiL) reduced cycles to failure. Using the

  6. Channel plate for DNA sequencing

    Science.gov (United States)

    Douthart, Richard J.; Crowell, Shannon L.

    1998-01-01

    This invention is a channel plate that facilitates data compaction in DNA sequencing. The channel plate has a length, a width and a thickness, and further has a plurality of channels that are parallel. Each channel has a depth partially through the thickness of the channel plate. Additionally an interface edge permits electrical communication across an interface through a buffer to a deposition membrane surface.

  7. Influence of periodontal tissue thickness on buccal plate remodelling on immediate implants with xenograft.

    Science.gov (United States)

    Maia, Luciana P; Reino, Danilo M; Muglia, Valdir A; Almeida, Adriana L G; Nanci, Antonio; Wazen, Rima M; de Oliveira, Paulo T; Palioto, Daniela B; Novaes, Arthur B

    2015-06-01

    To evaluate the influence of gingival thickness and bone grafting on buccal bone plate remodelling after immediate implant placement in sockets with thin buccal bone, using a flapless approach. The gingiva of eight dogs was thinned at one side of the mandible, mandibular premolars were extracted without flaps, and four implants were installed on each side at 1.5 mm from the buccal bone. The sites were randomly assigned into: TG (test group) = thin gingiva; TG + GM (TG with grafting material); CG (control group) = normal gingiva; and CG + GM (CG with grafting material). After 12 weeks the dogs were sacrificed and the samples were processed for histological analysis. All animals exhibited a thin buccal bone initially. In all the experimental groups the buccal gap was filled with newly formed bone and the buccal bone level was slightly apical to the implant shoulder. There were no statistically significant differences among the groups for the histomorphometric parameters. The thickness of the buccal bone was a fundamental factor in buccal bone plate resorption, even with flapless implantation. The gingival thickness or the addition of a biomaterial in the gap did not influence the results. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. From bone biology to bone analysis.

    NARCIS (Netherlands)

    Schoenau, E.; Saggese, G.; Peter, F.; Baroncelli, G.I.; Shaw, N.J.; Crabtree, N.J.; Zadik, Z.; Neu, C.M.; Noordam, C.; Radetti, G.; Hochberg, Z.

    2004-01-01

    Bone development is one of the key processes characterizing childhood and adolescence. Understanding this process is not only important for physicians treating pediatric bone disorders, but also for clinicians and researchers dealing with postmenopausal and senile osteoporosis. Bone densitometry has

  9. Extracortical plate fixation with new plate inserts and cerclage wires for the treatment of periprosthetic hip fractures.

    Science.gov (United States)

    Bastian, Johannes D; Butscher, Andre; Bigolin, Gianni; Zumstein, Matthias A; Nötzli, Hubert P

    2014-03-01

    Fixation of periprosthetic hip fractures with intracortical anchorage might not be feasible in cases with bulky implants and/or poor bone stock. Rotational stability of new plate inserts with extracortical anchorage for cerclage fixation was measured and compared to the stability found using a standard technique in a biomechanical setup using a torsion testing machine. In a synthetic PUR bone model, transverse fractures were fixed distally using screws and proximally by wire cerclages attached to the plates using "new" (extracortical anchorage) or "standard" (intracortical anchorage) plate inserts. Time to fracture consolidation and complications were assessed in a consecutive series of 18 patients (18 female; mean age 81 years, range 55-92) with periprosthetic hip fractures (ten type B1, eight type C-Vancouver) treated with the new device between July 2003 and July 2010. The "new" device showed a higher rotational stability than the "standard" technique (p Fractures showed radiographic consolidation after 14 ± 5 weeks (mean ± SD) postoperatively in patients. Revision surgery was necessary in four patients, unrelated to the new technique. In periprosthetic hip fractures in which fixation with intracortical anchorage using conventional means might be difficult due to bulky revision stems and/or poor bone stock, the new device may be an addition to the range of existing implants.

  10. Bone mineral content and bone metabolism in young adults with severe periodontitis

    DEFF Research Database (Denmark)

    Wowern von, N.; Westergaard, J.; Kollerup, G.

    2001-01-01

    Bone loss, bone markers, bone metabolism, bone mineral content, osteoporosis, severe periodontitis......Bone loss, bone markers, bone metabolism, bone mineral content, osteoporosis, severe periodontitis...

  11. VISAS AND GREEN PLATES

    CERN Multimedia

    2000-01-01

    From 3 April 2000, all questions relating to visa requests for Switzerland, France, or Russia for a member of the personnel must be addressed to Ms. Agnita Querrou (telephone 72838, office 5-2-019, e-mail Agnita.Querrou@cern.ch).The Users' Office continues to deal with requests for letters of invitation and questions concerning visas for users in EP Division.Questions relating to removals, requests for green plates, to privileges of members of the personnel and to the importation of vehicles are still dealt with by Ms Zuzana Miller (telephone 79257, office 33-1-017, e-mail Zuzana.Muller@cern.ch) and Ms Joëlle Belleman (telephone 73962, office 33-1-019, e-mail Joelle.Belleman@cern.ch).

  12. Facts about Broken Bones

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Broken Bones KidsHealth / For Kids / Broken Bones What's in this ... sticking through the skin . What Happens When a Bone Breaks? It hurts to break a bone! It's ...

  13. Bone lesion biopsy

    Science.gov (United States)

    Bone biopsy; Biopsy - bone ... the cut, then pushed and twisted into the bone. Once the sample is obtained, the needle is ... sample is sent to a lab for examination. Bone biopsy may also be done under general anesthesia ...

  14. Metallographic examination of a failed Jewett nail-plate from a human femur

    International Nuclear Information System (INIS)

    Gray, R.J.; Zirkel, L.G. Jr.

    1976-01-01

    A type 316L wrought stainless steel Jewett nail-plate is one of several implant designs for bridging fractures in the proximal end of the femur. A soldier received a high velocity projectile in the trochanteric region of the femur. He was treated for a subtrochanteric fracture and greater trochanteric bone loss. After 9 months, hip varus angulation was progressively increasing. A Jewett nail-plate was inserted after valgus osteotomy and bone grafting of the unhealed fracture. The nail-plate fractured three weeks after surgery. Optical and scanning electron microscopy related the origin of failure to an impactor failure and subsequent microscopic scoring of the nail-plate during insertion into the abnormally hard femoral head. Photomicrographs showing the implant failure and evidences of corrosion after the short time in the body are presented. 12 figs

  15. Plate osteosynthesis of simple forearm fractures : LCP versus DC plates

    NARCIS (Netherlands)

    Stevens, Charles Tjerk; Ten Duis, Henk Jan

    The aim of this study was to compare the time to radiological bony union of simple A-type fractures of the forearm, treated with either a locking compression plate (LCP) or a dynamic compression plate (DCP). For each fracture, the relation between the use of compression and radiological healing time

  16. [Plate fixation and open wound treatment in infected intramedullar nails].

    Science.gov (United States)

    Lusser, G M; Müller, J

    1978-12-01

    In treating patients who present with an extensive non-union due to infected intramedullary nail, bone healing can be achieved within a few weeks through a policy of active management. Following excision of the infected tissue and thorough irrigation, the fracture site is stabilized by a plate fixation and a packet with cancellous bone. The wound overlying the bone is left open to granulate. No complications were observed during the course of healing in 7 cases (5 tibia, 2 femur) managed this way. The method is based on classical principles of orthopedics and the treatment of infection. Such has been its impressive success, that it would seem to warrant not only close attention but also strong recommendation.

  17. Biomechanical comparison of 4 different lateral plate constructs for distal fibula fractures.

    Science.gov (United States)

    Eckel, Tobin T; Glisson, Richard R; Anand, Prashanth; Parekh, Selene G

    2013-11-01

    Displaced lateral malleolar fractures are often treated with reduction and surgical stabilization. However, there has not been a comprehensive laboratory comparison to determine the most appropriate device for treating these patients. This study subjected a range of contemporary lateral fibular plates to a series of mechanical tests designed to reveal performance differences. Forty fresh frozen lower extremities were divided into 4 groups. A Weber B distal fibula fracture was simulated with an osteotomy and stabilized using 1 of 4 plate systems: a standard Synthes one-third tubular plate with interfragmentary lag screw, a Synthes LCP locking plate with lag screw, an Orthohelix MaxLock Extreme low-profile locking plate with lag screw, or a TriMed Sidewinder nonlocking plate. Controlled monotonic bending and cyclic torsional loading were applied and bending stiffness, torsional stiffness, and fracture site motion were quantified. Resistance to cyclic torsional loading was determined by quantifying the number of loads withstood before excessive rotation occurred. Correlation between bone mineral density and each of the mechanical measures was determined. There was no difference in angulation or bending stiffness between plates. All plates except the LCP showed greater lateral deflection than in the other bending directions. Bending stiffness was lowest in lateral distal fragment deflection for all 4 plates. There was a positive correlation between bone mineral density and bending stiffness for all plate types. There was no difference in fracture site rotation between plate types in internal or external torsion, but internal rotation of the distal fragment consistently exceeded external rotation. Torsional stiffness in external rotation exceeded stiffness in internal rotation in nearly all specimens. LCP plates performed relatively poorly under cyclic torsion. Significant differences in plate performance were not demonstrated. The effects of bone quality variability

  18. Modeling particulate removal in plate-plate and wire-plate electrostatic precipitators

    Directory of Open Access Journals (Sweden)

    S Ramechecandane

    2016-09-01

    Full Text Available The present study is concerned with the modeling of electrically charged particles in a model plate-plate and a single wire-plate electrostatic precipitator (ESP. The particle concentration distributions for both a plate-plate and a wire-plate ESP are calculated using a modified drift flux model. Numerical investigations are performed using the modified drift flux model for particle number concentration, in addition to the RNG k - ε model for the mean turbulent flow field and the Poisson equation for the electric field. The proposed model and the outlined methodology for coupling the flow field, electric field, charging kinetics and particle concentration is applied to two model precipitators that are truly representative of a wide class of commercialized ESPs. The present investigation is quite different from the earlier studies as it does not make assumptions like a homogeneous electric field or an infinite turbulent diffusivity. The electric field calculated is a strong function of position and controls the migration velocity of particles. Hence, the proposed model can be implemented in a flow solver to obtain a full-fledged solution for any kind of ESP with no limitations on the particle number concentration, as encountered in a Lagrangian approach. The effect of turbulent diffusivity on particle number concentration in a plate-plate ESP is investigated in detail and the results obtained are compared with available experimental data. Similarly, the effect of particle size/diameter and applied electric potential on the accumulative collection performance in the case of a wire-plate ESP is studied and the results obtained are compared with available numerical data. The numerical results obtained using the modified drift flux model for both the plate-plate and wire-plate ESP are in close agreement with available experimental and numerical data.

  19. Locking plates in distal humerus fractures: study of 43 patients

    Directory of Open Access Journals (Sweden)

    Gupta Rakesh Kumar

    2013-08-01

    Full Text Available 【Abstract】Objective: The treatment of multi-fragmentary, intraarticular fractures of the distal humerus is difficult, even in young patients with bone of good quality. Small distal fragment, diminished bone mineral quality and increased trauma-associated joint destruction make stable joint reconstruction more problematic. The anatomically preshaped locking plates allow angular stable fixation for these complex fractures. We evaluated functional results of patients treated with open reduction and internal fixation with distal humerus locking plates for complex distal hu-merus fractures. Methods: Forty-three consecutive patients with ar-ticular fractures of the distal humerus were treated by open reduction and internal fixation with AO distal humerus plate system and locking reconstruction plates. Forty patients were available for the final outcome analysis. According to AO/ASIF classification, there were 2 cases of type A2, 4 cases of type A3, 1 case of type B1, 1 case of type B2, 14 cases of type C1, 7 cases of type C2 and 11 cases of type C3. Open reduction with triceps splitting technique was used in all patients. The clinical and radiographic follow-up was performed and outcome measures included pain assessment, range of motion, and Mayo elbow performance score. Results: Forty patients were available for the final outcome analysis. There were 29 males and 11 females with an average age of 38.4 years (18-73 years. Clinical and ra-diological consolidation of the fracture was observed in all cases at an average of 11.6 weeks (9-14 weeks. The average follow-up was 12 months (10-18 months. Using the Mayo elbow performance score the results obtained were graded as excellent or good results in 33 patients (82.5%. One pa-tient had superficial infection, and 4 had myositis ossificans. There were no cases of primary malposition or secondary displacement, implant failure or ulnar neuropathy. Conclusion: Anatomically preshaped distal humerus locking

  20. Osteoclasts prefer aged bone

    DEFF Research Database (Denmark)

    Henriksen, K; Leeming, Diana Julie; Byrjalsen, I

    2007-01-01

    We investigated whether the age of the bones endogenously exerts control over the bone resorption ability of the osteoclasts, and found that osteoclasts preferentially develop and resorb bone on aged bone. These findings indicate that the bone matrix itself plays a role in targeted remodeling...... of aged bones....

  1. Diaphyseal long bone nonunions - types, aetiology, economics, and treatment recommendations.

    Science.gov (United States)

    Rupp, Markus; Biehl, Christoph; Budak, Matthäus; Thormann, Ulrich; Heiss, Christian; Alt, Volker

    2018-02-01

    The intention of the current article is to review the epidemiology with related socioeconomic costs, pathophysiology, and treatment options for diaphyseal long bone delayed unions and nonunions. Diaphyseal nonunions in the tibia and in the femur are estimated to occur 4.6-8% after modern intramedullary nailing of closed fractures with an even much higher risk in open fractures. There is a high socioeconomic burden for long bone nonunions mainly driven by indirect costs, such as productivity losses due to long treatment duration. The classic classification of Weber and Cech of the 1970s is based on the underlying biological aspect of the nonunion differentiating between "vital" (hypertrophic) and "avital" (hypo-/atrophic) nonunions, and can still be considered to represent the basis for basic evaluation of nonunions. The "diamond concept" units biomechanical and biological aspects and provides the pre-requisites for successful bone healing in nonunions. For humeral diaphyseal shaft nonunions, excellent results for augmentation plating were reported. In atrophic humeral shaft nonunions, compression plating with stimulation of bone healing by bone grafting or BMPs seem to be the best option. For femoral and tibial diaphyseal shaft fractures, dynamization of the nail is an atraumatic, effective, and cheap surgical possibility to achieve bony consolidation, particularly in delayed nonunions before 24 weeks after initial surgery. In established hypertrophic nonunions in the tibia and femur, biomechanical stability should be addressed by augmentation plating or exchange nailing. Hypotrophic or atrophic nonunions require additional biological stimulation of bone healing for augmentation plating.

  2. Bone marker gene expression in calvarial bones: different bone microenvironments.

    Science.gov (United States)

    Al-Amer, Osama

    2017-12-01

    In calvarial mice, mesenchymal stem cells (MSCs) differentiate into osteoprogenitor cells and then differentiate into osteoblasts that differentiate into osteocytes, which become embedded within the bone matrix. In this case, the cells participating in bone formation include MSCs, osteoprogenitor cells, osteoblasts and osteocytes. The calvariae of C57BL/KaLwRijHsD mice consist of the following five bones: two frontal bones, two parietal bones and one interparietal bone. This study aimed to analyse some bone marker genes and bone related genes to determine whether these calvarial bones have different bone microenvironments. C57BL/KaLwRijHsD calvariae were carefully excised from five male mice that were 4-6 weeks of age. Frontal, parietal, and interparietal bones were dissected to determine the bone microenvironment in calvariae. Haematoxylin and eosin staining was used to determine the morphology of different calvarial bones under microscopy. TaqMan was used to analyse the relative expression of Runx2, OC, OSX, RANK, RANKL, OPG, N-cadherin, E-cadherin, FGF2 and FGFR1 genes in different parts of the calvariae. Histological analysis demonstrated different bone marrow (BM) areas between the different parts of the calvariae. The data show that parietal bones have the smallest BM area compared to frontal and interparietal bones. TaqMan data show a significant increase in the expression level of Runx2, OC, OSX, RANKL, OPG, FGF2 and FGFR1 genes in the parietal bones compared with the frontal and interparietal bones of calvariae. This study provides evidence that different calvarial bones, frontal, parietal and interparietal, contain different bone microenvironments.

  3. Bone matrix microdamage and vascular changes characterize bone marrow lesions in the subchondral bone of knee osteoarthritis.

    Science.gov (United States)

    Muratovic, Dzenita; Findlay, David M; Cicuttini, Flavia M; Wluka, Anita E; Lee, Yea-Rin; Kuliwaba, Julia S

    2018-03-01

    Bone marrow lesions (BMLs) in the subchondral bone in osteoarthritis (OA) are suggested to be multifactorial, although the pathogenic mechanisms are unknown. Bone metabolism and cardiovascular risk factors associate with BML in epidemiologic studies. However, there are no studies at the tissue level investigating the relationship between these processes and BML. The aim of this study was to investigate the relationship between BMLs in the tibial plateau (TP) of knee OA and bone matrix microdamage, osteocyte density and vascular changes. TP were obtained from 73 patients at total knee replacement surgery and BMLs were identified ex vivo in TP tissue using MRI. Comparator 'No BML' tissue was from matched anatomical sites to the BMLs. Quantitative assessment was made of subchondral bone microdamage, bone resorption indices, osteocyte cellularity, and vascular features. Several key parameters were different between BML and No BML tissue. These included increased microcrack burden (p = .01, p = .0001), which associated positively with bone resorption and negatively with cartilage volume, and greater osteocyte numerical density (p = .02, p = .01), in the subchondral bone plate and subchondral trabeculae, respectively. The marrow tissue within BML zones contained increased arteriolar density (p = .04, p = .0006), and altered vascular characteristics, in particular increased wall thickness (p = .007) and wall:lumen ratio (wall thickness over internal lumen area) (p = .001), compared with No BML bone. Increased bone matrix microdamage and altered vasculature in the subchondral bone of BMLs is consistent with overloading and vascular contributions to the formation of these lesions. Given the important role of BMLs in knee OA, these contributing factors offer potential targets for the treatment and prevention of knee OA. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.

  4. Biomechanical comparison of the stable efficacy of two anterior plating systems.

    Science.gov (United States)

    Yang, Saiwei; Wang, Lee-Wei

    2003-07-01

    To compare the immediate stable efficacy and load sharing effect of two types of anterior cervical screw-plating instrumentations: the Morscher Synthes titanium locking screw-plate system and the Caspar trapezoidal screw-plate system. Fresh porcine cervical spines with intact, two surgery unstable models, and then reconstructed with or without screw-plating instruments were compared in three physiological loading conditions. Two markedly instrumentation systems--Morscher Synthes titanium cervical locking screw-plate and Caspar trapezoidal screw-plate systems are commonly used in management of complex cervical spine disorders. Although the biomechanical study showed that the lower cost Caspar system performed superior in extension before and after plate fatigue, the clinic evaluations of two systems were contradictory. So (1) does the titanium cervical locking plate system pay for its higher cost? and (2) what is the load sharing character of strut graft in one level corpectomy? Eight fresh ligamentous porcine cervical spines from C3 to C7 were undergone axial compression, rotation and sagittal flexion tests. The biomechanical experiment was sequentially repeated for the intact, C5-6 discectomy, C5 corpectomy, and then stabilized by either type of plate fixation devices with or without polymethylmethacrylate bone cement grafting. Strains measured by an extensometer across the operated motion segment were used as the index of stability. Analysis of the strain data showed both types of anterior fixation plate systems provided adequate-restored stability for the spinal column only aided with polymethylmethacrylate construction. Statistically, there was no significant difference in biomechanical evaluation for the stability effect between much cost Morscher Synthes plate and Caspar plate system (pfailure. Statistically both systems showed similar stable efficacy, however, the Morscher Synthes cervical locking plate system might provide better stable effect in higher

  5. Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction--a biomechanic study in a cadaveric model.

    Science.gov (United States)

    Drobetz, Herwig; Bryant, Adam L; Pokorny, Tom; Spitaler, Ralf; Leixnering, Martin; Jupiter, Jesse B

    2006-04-01

    Treatment of extension fractures of the distal radius with volar fixed-angle plates has become increasingly popular in the past 2 years. It has been observed clinically that placement of the distal screws as close as possible to the subchondral zone is crucial to maintain radial length after surgery. The purposes of this study were (1) to evaluate radial shortening after plating with regard to plate position and (2) to evaluate whether plate position has an influence on the strength and rigidity of the plate-screw construct. An extra-articular fracture (AO classification, A3) was created in 7 pairs of fresh-frozen human cadaver radiuses. The radiuses then were plated with a volar distal radius locking compression plate. Seven plates were applied subchondrally; 7 plates were applied 4.5 mm to 7.5 mm proximal to the subchondral zone. The specimens were loaded with 800-N loads for 2,000 cycles to evaluate radial shortening in the 2 groups. Each specimen then was loaded to failure. Radial shortening was significantly greater when the distal screws were placed proximal to the subchondral zone. The amount of shortening after cyclic loading correlated significantly with the distance the distal screws were placed from the subchondral zone. Rigidity of the plate systems was significantly higher in radiuses in which the distal screws were placed close to the subchondral zone. To maintain radial length after volar fixed-angle plating, placement of the distal screws as subchondral as possible is essential. The subchondral plate-screw-bone constructs showed significantly greater rigidity, indicating higher resistance to postoperative loads and displacement forces.

  6. Laterally Loaded Nail-Plates

    DEFF Research Database (Denmark)

    Nielsen, Jacob; Rathkjen, Arne

    Load-displacement curves from about 200 short-term and laterally loaded nail-plate joints are analysed. The nail-plates are from Gang-Nail Systems, type GNA 20 S. The test specimens and the measuring systems are described. The tests are divided into 32 different series. The influence of the number...

  7. Seismic link at plate boundary

    Indian Academy of Sciences (India)

    time series to determine the causality and related orientation. The resulting link orientations at the plate boundary conditions indicate that causal triggering seems to be localized along a major fault, as a stress transfer between two major faults, and parallel to the geothermal area extension. 1. Introduction. Plate boundaries ...

  8. Scintillating plate calorimeter optical design

    International Nuclear Information System (INIS)

    McNeil, R.; Fazely, A.; Gunasingha, R.; Imlay, R.; Lim, J.

    1990-01-01

    A major technical challenge facing the builder of a general purpose detector for the SSC is to achieve an optimum design for the calorimeter. Because of its fast response and good energy resolution, scintillating plate sampling calorimeters should be considered as a possible technology option. The work of the Scintillating Plate Calorimeter Collaboration is focused on compensating plate calorimeters. Based on experimental and simulation studies, it is expected that a sampling calorimeter with alternating layers of high-Z absorber (Pb, W, DU, etc.) and plastic scintillator can be made compensating (e/h = 1.00) by suitable choice of the ratio of absorber/scintillator thickness. Two conceptual designs have been pursued by this subsystem collaboration. One is based on lead as the absorber, with read/out of the scintillator plates via wavelength shifter fibers. The other design is based on depleted uranium as the absorber with wavelength shifter (WLS) plate readout. Progress on designs for the optical readout of a compensating scintillator plate calorimeter are presented. These designs include readout of the scintillator plates via wavelength shifter plates or fiber readout. Results from radiation damage studies of the optical components are presented

  9. MyPlate Food Guide

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español MyPlate Food Guide KidsHealth / For Teens / MyPlate Food Guide What's ... and other sugary drinks. Avoid large portions . Five Food Groups Different food groups have different nutrients and ...

  10. Aseptic laboratory techniques: plating methods.

    Science.gov (United States)

    Sanders, Erin R

    2012-05-11

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: Perform plating procedures without contaminating media. Isolate single bacterial colonies by the streak-plating

  11. Strong Plate, Weak Slab Dichotomy

    Science.gov (United States)

    Petersen, R. I.; Stegman, D. R.; Tackley, P.

    2015-12-01

    Models of mantle convection on Earth produce styles of convection that are not observed on Earth.Moreover non-Earth-like modes, such as two-sided downwellings, are the de facto mode of convection in such models.To recreate Earth style subduction, i.e. one-sided asymmetric recycling of the lithosphere, proper treatment of the plates and plate interface are required. Previous work has identified several model features that promote subduction. A free surface or pseudo-free surface and a layer of material with a relatively low strength material (weak crust) allow downgoing plates to bend and slide past overriding without creating undue stress at the plate interface. (Crameri, et al. 2012, GRL)A low viscosity mantle wedge, possibly a result of slab dehydration, decouples the plates in the system. (Gerya et al. 2007, Geo)Plates must be composed of material which, in the case of the overriding plate, are is strong enough to resist bending stresses imposed by the subducting plate and yet, as in the case of the subducting plate, be weak enough to bend and subduct when pulled by the already subducted slab. (Petersen et al. 2015, PEPI) Though strong surface plates are required for subduction such plates may present a problem when they encounter the lower mantle.As the subducting slab approaches the higher viscosity, lower mantle stresses are imposed on the tip.Strong slabs transmit this stress to the surface.There the stress field at the plate interface is modified and potentially modifies the style of convection. In addition to modifying the stress at the plate interface, the strength of the slab affects the morphology of the slab at the base of the upper mantle. (Stegman, et al 2010, Tectonophysics)Slabs that maintain a sufficient portion of their strength after being bent require high stresses to unbend or otherwise change their shape.On the other hand slabs that are weakened though the bending process are more amenable to changes in morphology. We present the results of

  12. Fundamental processes in ion plating

    International Nuclear Information System (INIS)

    Mattox, D.M.

    1980-01-01

    Ion plating is a generic term applied to film deposition processes in which the substrate surface and/or the depositing film is subjected to a flux of high energy particles sufficient to cause changes in the interfacial region of film properties compared to a nonbombarded deposition. Ion plating is being accepted as an alternative coating technique to sputter deposition, vacuum evaporation and electroplating. In order to intelligently choose between the various deposition techniques, the fundamental mechanisms, relating to ion plating, must be understood. This paper reviews the effects of low energy ion bombardment on surfaces, interface formation and film development as they apply to ion plating and the implementation and applications of the ion plating process

  13. Posterior coronal plating for tibial fractures: technique and advantages

    Directory of Open Access Journals (Sweden)

    Montu Jain

    2014-04-01

    Full Text Available Objective:Tibial shaft fractures are straightforward to treat but when associated with soft tissue injury particularly at the nail entry/plate insertion site or there is significant comminution proximally or a large butterfly fragment/a second split component in the posterior coronal plane, it is a challenge to the treating surgeon. The aim of the present report is to describe the technique of posterior coronal plating in such a scenario and its advantages. Methods:Between July 2008 and June 2011, 12 patients were pro spectively treated by this approach using 4.5 mm broad dynamic compression plates. Results:The time of bony consolidation and full weight bearing averaged 21.7 weeks (range, 16-26 weeks. Patients were followed up for at least 24 months (range, 24-48 months. At 1 year postoper atively, no loss in reduction or alignment was observed. Mean Hospital for Lower Extremity Measurement Functional Score was 72.8 (range, 64-78. All patients were satisfied with their treatment outcomes. Conclusion:Direct posterior approach and fixation using prone position helps to visualise the fracture fragments and provide rigid fixation. The approach is simple and extensile easily, apart from advantages of less soft tissue and hardware problems compared to standard medial or lateral plating. Key words: Tibial fractures; Bone plates; Orthopedic procedures

  14. [Frontier in bone biology].

    Science.gov (United States)

    Takeda, Shu

    2015-10-01

    Bone is an active organ in which bone mass is maintained by the balance between osteoblastic bone formation and osteoclastic bone resorption, i.e., coupling of bone formation and bone resorption. Recent advances in molecular bone biology uncovered the molecular mechanism of the coupling. A fundamental role of osteocyte in the maintenance of bone mass and whole body metabolism has also been revealed recently. Moreover, neurons and neuropeptides have been shown to be intimately involved in bone homeostasis though inter-organ network, in addition to "traditional" regulators of bone metabolism such as soluble factors and cytokines

  15. Influence of cortical endplates on ultrasonic properties of trabecular bone

    International Nuclear Information System (INIS)

    Kim, Yoon Mi; Lee, Kang Il

    2015-01-01

    The present study investigated the influence of thick cortical endplates on the ultrasonic properties of trabecular bone in a femur with a high fracture risk. Twelve trabecular bone samples were prepared from bovine femurs, and acrylic plates with thicknesses of 1.25, 1.80, and 2.75 mm were manufactured to simulate the cortical endplates using acrylic with a density and a sound speed similar to cortical bone. Although the thickness of the acrylic plates attached to the two sides of the trabecular bone increased, high correlations were observed between the speed of sound and the apparent bone density of the trabecular bone, with Pearson's correlation coefficients of 0.80-0.86. High correlations were also observed between the attenuation coefficient at 0.5 mm and the apparent bone density of the trabecular bone, with Pearson's correlation coefficients of 0.84-0.91. These results suggest that the speed of sound and attenuation coefficient at a specific frequency measured in a femur with relatively thick cortical endplates compared to the calcaneus could be used as indices for predicting the bone mineral density of the femur.

  16. Influence of cortical endplates on ultrasonic properties of trabecular bone

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yoon Mi; Lee, Kang Il [Dept. of Physics, Kangwon National University, Chuncheon (Korea, Republic of)

    2015-04-15

    The present study investigated the influence of thick cortical endplates on the ultrasonic properties of trabecular bone in a femur with a high fracture risk. Twelve trabecular bone samples were prepared from bovine femurs, and acrylic plates with thicknesses of 1.25, 1.80, and 2.75 mm were manufactured to simulate the cortical endplates using acrylic with a density and a sound speed similar to cortical bone. Although the thickness of the acrylic plates attached to the two sides of the trabecular bone increased, high correlations were observed between the speed of sound and the apparent bone density of the trabecular bone, with Pearson's correlation coefficients of 0.80-0.86. High correlations were also observed between the attenuation coefficient at 0.5 mm and the apparent bone density of the trabecular bone, with Pearson's correlation coefficients of 0.84-0.91. These results suggest that the speed of sound and attenuation coefficient at a specific frequency measured in a femur with relatively thick cortical endplates compared to the calcaneus could be used as indices for predicting the bone mineral density of the femur.

  17. Minimally invasive plate osteosynthesis of the distal fibula with the locking compression plate: first experience of 20 cases.

    Science.gov (United States)

    Hess, Florian; Sommer, Christoph

    2011-02-01

    The aim of this study was to evaluate the clinical feasibility and the possible complications associated with minimally invasive plate osteosynthesis of the distal fibula. Regional county hospital. All patients with Orthopaedic Trauma Association 42, 43, 44 fractures of the distal tibia requiring plate fixation of the distal fibula were included in this cohort study. A consecutive series of 701 internally fixed fractures of tibia and ankle yielded 20 fibular fractures treated with this technique. Fractures were treated with the minimally invasive plate osteosynthesis technique using an angular stable screw-plate system for the fibula. Clinical and radiologic outcomes at 24 months. Seventeen fractures healed without complication at an average of 9 weeks. Three aseptic nonunions were recorded: one in a pilon fracture (Orthopaedic Trauma Association 43-C3) and one in a distal lower leg fracture (Orthopaedic Trauma Association 43-A3), both with severe closed soft tissue injury (as a result of a crush mechanism). The third one was in an ankle fracture dislocation (OTA 44-C1) with delayed treatment and inadequate reduction of the simple fibula fracture. Although this technique is comparable to minimally invasive plate osteosynthesis in the tibia or femur, it appears to be more difficult as a result of small bone size. As a result, we reserve this technique for selected complex fractures of the distal fibula with critical soft tissue conditions.

  18. The Golosyiv plate archive digitisation

    Science.gov (United States)

    Sergeeva, T. P.; Sergeev, A. V.; Pakuliak, L. K.; Yatsenko, A. I.

    2007-08-01

    The plate archive of the Main Astronomical Observatory of the National Academy of Sciences of Ukraine (Golosyiv, Kyiv) includes about 85 000 plates which have been taken in various observational projects during 1950-2005. Among them are about 25 000 of direct northern sky area plates and more than 600 000 plates containing stellar, planetary and active solar formations spectra. Direct plates have a limiting magnitude of 14.0-16.0 mag. Since 2002 we have been organising the storage, safeguarding, cataloguing and digitization of the plate archive. The very initial task was to create the automated system for detection of astronomical objects and phenomena, search of optical counterparts in the directions of gamma-ray bursts, research of long period, flare and other variable stars, search and rediscovery of asteroids, comets and other Solar System bodies to improve the elements of their orbits, informational support of CCD observations and space projects, etc. To provide higher efficiency of this work we have prepared computer readable catalogues and database for 250 000 direct wide field plates. Now the catalogues have been adapted to Wide Field Plate Database (WFPDB) format and integrated into this world database. The next step will be adaptation of our catalogues, database and images to standards of the IVOA. Some magnitude and positional accuracy estimations for Golosyiv archive plates have been done. The photometric characteristics of the images of NGC 6913 cluster stars on two plates of the Golosyiv's double wide angle astrograph have been determined. Very good conformity of the photometric characteristics obtained with external accuracies of 0.13 and 0.15 mag. has been found. The investigation of positional accuracy have been made with A3± format fixed bed scanner (Microtek ScanMaker 9800XL TMA). It shows that the scanner has non-detectable systematic errors on the X-axis, and errors of ± 15 μm on the Y-axis. The final positional errors are about ± 2 μm (

  19. Indonesian Landforms and Plate Tectonics

    Directory of Open Access Journals (Sweden)

    Herman Th. Verstappen

    2014-06-01

    Full Text Available DOI: 10.17014/ijog.v5i3.103The horizontal configuration and vertical dimension of the landforms occurring in the tectonically unstable parts of Indonesia were resulted in the first place from plate tectonics. Most of them date from the Quaternary and endogenous forces are ongoing. Three major plates – the northward moving Indo-Australian Plate, the south-eastward moving SE-Asian Plate and the westward moving Pacific Plate - meet at a plate triple-junction situated in the south of New Guinea’s Bird’s Head. The narrow North-Moluccan plate is interposed between the Asia and Pacific. It tapers out northward in the Philippine Mobile Belt and is gradually disappearing. The greatest relief amplitudes occur near the plate boundaries: deep ocean trenches are associated with subduction zones and mountain ranges with collision belts. The landforms of the more stable areas of the plates date back to a more remote past and, where emerged, have a more subdued relief that is in the first place related to the resistance of the rocks to humid tropical weathering Rising mountain ranges and emerging island arcs are subjected to rapid humid-tropical river erosions and mass movements. The erosion products accumulate in adjacent sedimentary basins where their increasing weight causes subsidence by gravity and isostatic compensations. Living and raised coral reefs, volcanoes, and fault scarps are important geomorphic indicators of active plate tectonics. Compartmental faults may strongly affect island arcs stretching perpendicular to the plate movement. This is the case on Java. Transcurrent faults and related pull-apart basins are a leading factor where plates meet at an angle, such as on Sumatra. The most complicated situation exists near the triple-junction and in the Moluccas. Modern research methods, such as GPS measurements of plate movements and absolute dating of volcanic outbursts and raised coral reefs are important tools. The mega-landforms resulting

  20. Biomechanical comparison of conventional and anatomical calcaneal plates for the treatment of intraarticular calcaneal fractures - a finite element study.

    Science.gov (United States)

    Yu, Bin; Chen, Wen-Chuan; Lee, Pei-Yuan; Lin, Kang-Ping; Lin, Kun-Jhih; Tsai, Cheng-Lun; Wei, Hung-Wen

    2016-10-01

    Initial stability is essential for open reduction internal fixation of intraarticular calcaneal fractures. Geometrical feature of a calcaneal plate is influential to its endurance under physiological load. It is unclear if conventional and pre-contoured anatomical calcaneal plates may exhibit differently in biomechanical perspective. A Sanders' Type II-B intraarticular calcaneal fracture model was reconstructed to evaluate the effectiveness of calcaneal plates using finite element methods. Incremental vertical joint loads up to 450 N were exerted on the subtalar joint to evaluate the stability and safety of the calcaneal plates and bony structure. Results revealed that the anatomical calcaneal plate model had greater average structural stiffness (585.7 N/mm) and lower von Mises stress on the plate (774.5 MPa) compared to those observed in the conventional calcaneal plate model (stiffness: 430.9 N/mm; stress on plate: 867.1 MPa). Although both maximal compressive and maximal tensile stress and strain were lower in the anatomical calcaneal plate group, greater loads on fixation screws were found (average 172.7 MPa compared to 82.18 MPa in the conventional calcaneal plate). It was noted that high magnitude stress concentrations would occur where the bone plate bridges the fracture line on the lateral side of the calcaneus bone. Sufficient fixation strength at the posterolateral calcaneus bone is important for maintaining subtalar joint load after reduction and fixation of a Sanders' Type II-B calcaneal fracture. In addition, geometrical design of a calcaneal plate should worth considering for the mechanical safety in practical usage.

  1. Predicting bone strength with ultrasonic guided waves

    Science.gov (United States)

    Bochud, Nicolas; Vallet, Quentin; Minonzio, Jean-Gabriel; Laugier, Pascal

    2017-03-01

    Recent bone quantitative ultrasound approaches exploit the multimode waveguide response of long bones for assessing properties such as cortical thickness and stiffness. Clinical applications remain, however, challenging, as the impact of soft tissue on guided waves characteristics is not fully understood yet. In particular, it must be clarified whether soft tissue must be incorporated in waveguide models needed to infer reliable cortical bone properties. We hypothesize that an inverse procedure using a free plate model can be applied to retrieve the thickness and stiffness of cortical bone from experimental data. This approach is first validated on a series of laboratory-controlled measurements performed on assemblies of bone- and soft tissue mimicking phantoms and then on in vivo measurements. The accuracy of the estimates is evaluated by comparison with reference values. To further support our hypothesis, these estimates are subsequently inserted into a bilayer model to test its accuracy. Our results show that the free plate model allows retrieving reliable waveguide properties, despite the presence of soft tissue. They also suggest that the more sophisticated bilayer model, although it is more precise to predict experimental data in the forward problem, could turn out to be hardly manageable for solving the inverse problem.

  2. Technique to assess the alveolar bone width for immediate implant placement in fresh extraction sockets

    Directory of Open Access Journals (Sweden)

    Neeraj Kumar Chandraker

    2013-01-01

    Conclusion: This technique will help the surgeon understand the thickness of labial plate especially the apical region without reflecting the flap, also aid in selection of proper dimension of dental implant, and if bone graft is needed.

  3. Stability of Plates and Plated Structures - General Report

    Czech Academy of Sciences Publication Activity Database

    Maquoi, R.; Škaloud, Miroslav

    2000-01-01

    Roč. 55, 1-3 (2000), s. 45-68 ISSN 0143-974X. [Stability and Ductility of Steel Structures . Timisoara, 09.09.1999-11.09.1999] R&D Projects: GA ČR GA103/97/0002; GA AV ČR IAA2071701 Keywords : stability * plates * plated structures * web breathing * design Subject RIV: JM - Building Engineering Impact factor: 0.418, year: 2000

  4. Plating on stainless steel alloys

    International Nuclear Information System (INIS)

    Dini, J.W.; Johnson, H.R.

    1981-01-01

    Quantitative adhesion data are presented for a variety of electroplated stainless steel type alloys. Results show that excellent adhesion can be obtained by using a Wood's nickel strike or a sulfamate nickel strike prior to final plating. Specimens plated after Wood's nickel striking failed in the deposit rather than at the interface between the substrate and the coating. Flyer plate quantitative tests showed that use of anodic treatment in sulfuric acid prior to Wood's nickel striking even further improved adhesion. In contrast activation of stainless steels by immersion or cathodic treatment in hydrochloric acid resulted in very reduced bond strengths with failure always occurring at the interface between the coating and substrate

  5. A biomechanical evaluation of locked plating for distal fibula fractures in an osteoporotic sawbone model.

    Science.gov (United States)

    Bariteau, Jason T; Fantry, Amanda; Blankenhorn, Brad; Lareau, Craig; Paller, David; Digiovanni, Christopher W

    2014-03-01

    Supination external rotation (SER) injuries are commonly fixed with a one third tubular neutralization plate. This study investigated if a combination locked plate with additional fixation options was biomechanically superior in osteoporotic bone and comminuted fracture models. Using an osteoporotic and a comminuted Sawbones model, SER injuries were fixed with a lag screw for simple oblique fibula fractures, and either a one third tubular neutralization plate or a locking plate. Samples were tested in stiffness, peak torque, displacement at failure, and torsion fatigue. There was no statistically significant difference in biomechanical testing for fractures treated with a lag screw and plate. For comminuted fractures, locked plating demonstrated statistically significant stiffer fixation. A combination locked plate is biomechanically superior to a standard one third tubular plate in comminuted SER ankle fractures. There was no biomechanical superiority between locked and one third tubular plates when the fracture was amenable to a lag screw. Copyright © 2013 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  6. Effects of radiation therapy on growing long bones

    Energy Technology Data Exchange (ETDEWEB)

    De Smet, A.A.; Kuhns, L.R.; Fayos, J.V.; Holt, J.F.

    1976-12-01

    Characteristic radiographic changes were seen in six of 14 children who received radiation therapy to the epiphyseal plate of a long bone. These changes, which include metaphyseal sclerosis, metaphyseal fraying, and epiphyseal plate widening, resemble rickets. In three patients, these changes were followed by development of a broad metaphyseal band of increased density. The absence of metaphyseal changes may indicate sterilization of cartilage cells and may be predictive of significant limb shortening.

  7. Dynamic Decompressive Craniotomy with a Novel Reversibly Expandable Plate.

    Science.gov (United States)

    Khanna, Rohit

    2017-07-01

    Objective  To assess the feasibility of a dynamic craniotomy procedure with the use of a novel reversibly expandable cranial bone flap fixation plate. The expandable plate allows outward bone flap migration with an increase in intracranial volume or intracranial pressure (ICP). Methods  Dynamic craniotomy intracranial hypertension compliance was evaluated in a skull model with progressive increase in intracranial volume and compared with the standard craniotomy with fixed plates. Results  Dynamic craniotomy provided significant control of ICP with increasing intracranial volume compared with the standard craniotomy. With an incremental increase in intracranial volume from 360 mL to 600 mL, the ICP increased from 2.6 to 91.9 mm Hg with the standard craniotomy, whereas with the dynamic craniotomy the ICP for similar intracranial volume increased from 2.5 to 25 mm Hg ( p  craniotomy procedure provides superior control of ICP with an abrupt intracranial volume increase when compared with the standard craniotomy. Georg Thieme Verlag KG Stuttgart · New York.

  8. The effects of bone remodeling inhibition by alendronate on 3-D microarchitecture of subchondral bone tissues in guinea pig primary osteoarthrosis

    DEFF Research Database (Denmark)

    Ding, Ming; Danielsen, Carl Christian; Hvid, Ivan

    2008-01-01

    . The remaining 3 groups (17-week groups) were left for an additional 8 weeks receiving the same treatment regimen before sacrifice. The left proximal tibiae were micro-CT scanned to quantify microarchitecture of subchondral bone, followed by mechanical testing and determination of collagen and mineral...... plate thickness. The 9-week and 17-week groups had similar changes of cancellous bone microarchitecture, with greater volume fraction, connectivity, and extremely plate-like structure. The 9-week ALN group had greater bone mineral concentration, and the 17-week ALN group had reduced collagen...... concentration, and greater mineral concentration. Treatment with ALN did not significantly change the mechanical properties of the cancellous bone. In conclusion, the present results suggest that increased subchondral bone density promotes OA progression and call for circumspection in using bone density...

  9. Methotrexate Toxicity in Growing Long Bones of Young Rats: A Model for Studying Cancer Chemotherapy-Induced Bone Growth Defects in Children

    Directory of Open Access Journals (Sweden)

    Chiaming Fan

    2011-01-01

    Full Text Available The advancement and intensive use of chemotherapy in treating childhood cancers has led to a growing population of young cancer survivors who face increased bone health risks. However, the underlying mechanisms for chemotherapy-induced skeletal defects remain largely unclear. Methotrexate (MTX, the most commonly used antimetabolite in paediatric cancer treatment, is known to cause bone growth defects in children undergoing chemotherapy. Animal studies not only have confirmed the clinical observations but also have increased our understanding of the mechanisms underlying chemotherapy-induced skeletal damage. These models revealed that high-dose MTX can cause growth plate dysfunction, damage osteoprogenitor cells, suppress bone formation, and increase bone resorption and marrow adipogenesis, resulting in overall bone loss. While recent rat studies have shown that antidote folinic acid can reduce MTX damage in the growth plate and bone, future studies should investigate potential adjuvant treatments to reduce chemotherapy-induced skeletal toxicities.

  10. Dating of cremated bones

    NARCIS (Netherlands)

    Lanting, JN; Aerts-Bijma, AT; van der Plicht, J; Boaretto, E.; Carmi, I.

    2001-01-01

    When dating unburnt bone, bone collagen, the organic fraction of the bone, is used. Collagen does not survive the heat of the cremation pyre, so dating of cremated bone has been considered impossible. Structural carbonate in the mineral fraction of the bone, however, survives the cremation process.

  11. The multigap resistive plate chamber

    Energy Technology Data Exchange (ETDEWEB)

    Zeballos, E. Cerron [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Crotty, I. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Hatzifotiadou, D. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Valverde, J. Lamas [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Univ. Louis Pasteur, Strasbourg (France); Neupane, S. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Williams, M. C. S. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Zichichi, A. [Univ. of Bologna, Bologna (Italy)

    2015-02-03

    The paper describes the multigap resistive plate chamber (RPC). This is a variant of the wide gap RPC. However it has much improved time resolution, while keeping all the other advantages of the wide gap RPC design.

  12. MyPlate Daily Checklist

    Science.gov (United States)

    ... Price Tag Read the Food Label Kitchen Timesavers Cooking for Your Family Tasty & Low-Cost Recipes Sample 2-Week Menus Resources for Professionals MyPlate Tip Sheets Print Materials Infographics 5 Ways ...

  13. Plate shell structures of glass

    DEFF Research Database (Denmark)

    Bagger, Anne

    to their curved shape. A plate shell structure maintains a high stiffness-to-weight ratio, while facilitating the use of plane structural elements. The study focuses on using laminated glass panes for the load bearing facets. Various methods of generating a plate shell geometry are suggested. Together with Ghent......, such as facet size, imperfections, and connection characteristics. The critical load is compared to that of a similar, but smoothly curved, shell structure. Based on the investigations throughout the study, a set of guidelines for the structural design of plate shells of glass is proposed.......This thesis is a study of plate shell structures -- a type of shell structure with a piecewise plane geometry, organized so that the load bearing system is constituted by distributed in-plane forces in the facets. The high stiffness-to-weight ratio of smoothly curved shell structures is mainly due...

  14. License plate recognition (phase B).

    Science.gov (United States)

    2010-06-01

    License Plate Recognition (LPR) technology has been used for off-line automobile enforcement purposes. The technology has seen mixed success with correct reading rate as high as 60 to 80% depending on the specific application and environment. This li...

  15. Armor Plate Surface Roughness Measurements

    National Research Council Canada - National Science Library

    Stanton, Brian; Coburn, William; Pizzillo, Thomas J

    2005-01-01

    ...., surface texture and coatings) that could become important at high frequency. We measure waviness and roughness of various plates to know the parameter range for smooth aluminum and rolled homogenous armor (RHA...

  16. PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures.

    Science.gov (United States)

    Schliemann, Benedikt; Seifert, Robert; Theisen, Christina; Gehweiler, Dominic; Wähnert, Dirk; Schulze, Martin; Raschke, Michael J; Weimann, Andre

    2017-01-01

    The high rigidity of metal implants may be a cause of failure after fixation of proximal humerus fractures. Carbon fiber-reinforced polyetheretherketone (PEEK) plates with a modulus similar to human cortical bone may help to overcome this problem. The present study assesses the biomechanical behavior of a PEEK plate compared with a titanium locking plate. Unstable two- and three-part fractures were simulated in 12 pairs of cadaveric humeri and were fixed with either a PEEK or a titanium locking plate using a pairwise comparison. With an optical motion capture system, the stiffness, failure load, plate bending, and the relative motion at the bone-implant interface and at the fracture site were evaluated. The mean load to failure for two- and three-part fracture fixations was, respectively, 191 N (range 102-356 N) and 142 N (range 102-169 N) in the PEEK plate group compared with 286 N (range 191-395 N) and 258 N (range 155-366 N) in the titanium locking plate group. The PEEK plate showed significantly more bending in both the two- and three-part fractures (p PEEK plate showed lower fixation strength and increased motion at the bone-implant interface compared with a titanium locking plate.

  17. Mechanical evaluation of bone gap filled with rigid formulations castor oil polyurethane and chitosan in horses

    Directory of Open Access Journals (Sweden)

    Rodrigo Crispim Moreira

    Full Text Available ABSTRACT: Often fractures of long bones in horses are comminuted and form bone gaps, which represent a major challenge for the fixation of these fractures by loss of contact between the fragments. Bone grafts help in treating this kind of fracture and synthetic materials have been gaining ground because of the limitations of autologous and heterologous grafts. In this study were performed compressive non destructive test in 10 bones with complete cross-bone gap in mid-diaphyseal of the third metacarpal bone of horses. Using a mechanism of "crossing" the 10 bones were used in the three groups (control, castor oil poliuretane and chitosan according to the filling material. After the test with maximum load of 1000N bone had a gap filled by another material and the test was repeated. Deformations caused on the whole bone, plate and bone tissue near and distant of gap were evaluated, using strain gauges adhered to the surface at these locations. There was a reduction in bone deformation from 14% (control to 3,5% and 4,8% by filling the gap with Chitosan and castor oil respectively, and a reduction of strain on the plate of 96% and 85% by filling gap with chitosan and castor respectively. An increase in intensity and direction of deformations occurred in bone near to gap after its filling; however, there was no difference in bone deformations occurring far the gap.

  18. Simple radiography by Imaging Plate

    Energy Technology Data Exchange (ETDEWEB)

    Takata, Shigeru; Koyama, Motoko; Tanizaki, Yoshiyuki [Tokyo Metropolitan Industrial Technology Research Insitute, Tokyo (Japan)

    1998-12-31

    Photo-stimulable phosphor is a material which emits luminescence by incitement of light. As useful photo-stimulable phosphor, alkali halide, like BaFBr: Eu, II - VI compound, like SrS: Eu and oxide, such as Al{sub 2}O{sub 3}: Care reported at present. Imaging Plate is a popular name of products, which is composed of thin layer of the phosphor fixed plastic plate. Photo-stimulable luminescence of Imaging Plate is emitted by scanning with narrow beam of incitement light. The light of luminescence is separated from incitement light by filter and it`s intensity is measured. The intensity of luminescence is proportional to absorbed dose of Imaging Plate from incident radiation. The map of luminescence intensity makes radiation image like radiograph taken by X-ray film. Reusability and usability of digital image are another advantage. The problem to solve of Imaging Plate are less resolution than X-ray film, expensive reading instrument and fading, which means decrease of luminescence intensity depend on elapse time after irradiation. High sensitivity of Imaging Plate makes possible of simple radiography by small radiation source. In Japanese law, sealed radioisotopes source less than 3.7 MBq can use without permission and register. If radiograph can be taken by sealed source less than 3.7 MBq, application of radiography is widely developed. So we try to take radiographs of some objects using Imaging Plate and sealed radioisotope sources under 3.7 MBq. As the result, useful radiographs are taken under conditions that exposure time is more than a few hours and distance between the source and the Plate is less than 30 cm. Quality of the image is poor than general radiograph by large radiation source. But the simple radiography taken by small source is of great value. (J.P.N.)

  19. Pulse plating of nickel deposits

    Energy Technology Data Exchange (ETDEWEB)

    Stimetz, C.J.; Stevenson, M.F.

    1980-02-01

    Pulse plated and conventional nickel deposits have been compared for differences in morphology, mechanical properties, and microstructure. The deposits were obtained from nickel sulfamate, nickel chloride, and Watts nickel plating solutions. No significant differences were found in the direct and pulse current deposits from the sulfamate and chloride solutions; however, significant differences in microstructure, yield strength, and microhardness were observed in deposits from the Watts nickel solution.

  20. Tibiotalocalcaneal arthrodesis with combined retrograde intramedullary nail and lateral L-plate.

    Science.gov (United States)

    Lui, Tun Hing

    2012-01-01

    Achieving stable fixation when performing tibiotalocalcaneal or tibiocalcaneal arthrodesis can be challenging. Patients undergoing these procedures often have osteopenia, poor bone stock, fragmentation of the bones of the foot and ankle, joint subluxation, or even dislocation. The author describes a technique of tibiotalocalcaneal arthrodesis with intramedullary nail fixation augmented by lateral plating through the transfibular approach. This can provide excellent exposure of the ankle and subtalar joints, morselized bone for grafting, and better construct stability. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Design aspects and clinical performance of the thrust plate hip prosthesis.

    Science.gov (United States)

    Jacob, H A C; Bereiter, H H; Buergi, M L

    2007-01-01

    The thrust plate hip prosthesis (TPP) was conceived to maintain the physiological stress distribution in the proximal femur so as to prevent bone atrophy in this region, often encountered after implantation of conventional stem-type prostheses. A thrust plate of TiAlNb is firmly fixed to the neck of the femur by means of a forged CoCrMo bolt introduced through the lateral cortex, just below the greater trochanter, and through the metaphysis. A boss that contains the bolt head rests on the lateral cortex. A proximal extension from the thrust plate terminates in the ball head of the hip joint. Bone remodelling causes the initial prestressing of the structure (primary stability) to decline, but full integration of the thrust plate with the underlying host bone affords secondary stability. A total of 102 TPPs were implanted in the Cantonal Hospital, Chur, Switzerland, from 1992 to 1999 in 84 patients. The TPP was selected particularly for patients of the younger age group (26-76). Through its ability to load the medial cortex of the proximal femur in a physiological manner, the cortical bone in this region is preserved. The mean Harris hip score is 97 points and the survival rate 98 per cent, 144 months post-operatively.

  2. Bilateral clavicle non-unions treated with anteroinferior locking compression plating (LCP": a case report

    NARCIS (Netherlands)

    Kloen, Peter

    2004-01-01

    The author reports the case of a 30-year-old female patient with bilateral atrophic non-union of the clavicle; the latter both healed after internal fixation with a locking compression plate fixed on the anteroinferior aspect of the clavicle, combined with autologous cancellous bone grafting. The

  3. Long-term functional outcome of mandibular reconstruction with stainless steel AO reconstruction plates

    NARCIS (Netherlands)

    van Minnen, B; Nauta, JM; Vermey, A; Bos, RRM; Roodenburg, JLN

    Mandibular continuity defects are usually reconstructed with bone grafts. However, factors associated with the tumour and the patient can still be reasons to choose reconstruction plates. The aim of this study was to find out the results of mandibular reconstructions with stainless steel AO

  4. Dorsal bridge plating or transarticular screws for Lisfranc fracture dislocations.

    Science.gov (United States)

    Kirzner, N; Zotov, P; Goldbloom, D; Curry, H; Bedi, H

    2018-04-01

    Aims The aim of this retrospective study was to compare the functional and radiological outcomes of bridge plating, screw fixation, and a combination of both methods for the treatment of Lisfranc fracture dislocations. Patients and Methods A total of 108 patients were treated for a Lisfranc fracture dislocation over a period of nine years. Of these, 38 underwent transarticular screw fixation, 45 dorsal bridge plating, and 25 a combination technique. Injuries were assessed preoperatively according to the Myerson classification system. The outcome measures included the American Orthopaedic Foot and Ankle Society (AOFAS) score, the validated Manchester Oxford Foot Questionnaire (MOXFQ) functional tool, and the radiological Wilppula classification of anatomical reduction. Results Significantly better functional outcomes were seen in the bridge plate group. These patients had a mean AOFAS score of 82.5 points, compared with 71.0 for the screw group and 63.3 for the combination group (p Foot Questionnaire score was 25.6 points in the bridge plate group, 38.1 in the screw group, and 45.5 in the combination group (p plate fixation is associated with a better anatomical reduction (p = 0.06). Myerson types A and C2 significantly predicted a poorer functional outcome, suggesting that total incongruity in either a homolateral or divergent pattern leads to worse outcomes. The greater the number of columns fixed the worse the outcome (p plating have better functional and radiological outcomes than those treated with transarticular screws or a combination technique. Cite this article: Bone Joint J 2018;100-B:468-74.

  5. A distal femoral supra-condylar plate: biomechanical comparison with condylar plate and first clinical application for treatment of supracondylar fracture.

    Science.gov (United States)

    Liang, Bowei; Ding, Zhenqi; Shen, Junguo; Zhai, Wenliang; Kang, Liangqi; Zhou, Liang; Sha, Mo; Liang, Dongzhu

    2012-08-01

    An anatomical supra-condylar plate is designed and analysed by biomechanical testing. The biomechanical properties of the supra-condylar and condylar plate were compared in six matched pairs of cadaveric femurs. A transverse osteotomy gap was created to simulate an OTA/AO type A3 supracondylar fracture. The left and right specimens were fitted with supra-condylar and condylar plate, respectively. Nondestructive axial compression, three-point bending and torsion tests were performed, and the peak load of the bone-implant construction was measured. The fracture site suitable for supra-condylar plate application and its correlation with femoral length were calculated. The gender influence on it was also discussed. The difference of stiffness between the supra-condylar and condyle groups were not significant (P > 0.05) at 363.4 and 362.5 N/mm for compression, 229.5 and 237.6 N/mm in the sagittal plane and 195.5 and 188.4 N/mm in the coronal plane for three-point bending, and 7.5 and 7.9 Nm/deg for axial torsion, respectively. The peak load was 4438 ± 136.15 N and 5215 ± 174.33 N, respectively, for the two groups. The average extent of the fracture site suitable for the application of the supra-condylar plate was 70.86 ± 4.61 mm. The femoral length and gender showed no influence on it. Despite the limited bone contact area provided by the supra-condylar plate, its construct stiffness is comparable to the condylar plate. The supra-condylar plate can be used to treat carefully-selected extra-articular supracondylar fractures.

  6. Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis

    Directory of Open Access Journals (Sweden)

    Jiang-Jun Zhou

    2017-01-01

    Full Text Available In this study, we developed and validated a refined three-dimensional finite element model of middle femoral comminuted fracture to compare the biomechanical stability after two kinds of plate fixation: a newly designed assembly locking compression plate (NALCP and a locking compression plate (LCP. CT data of a male volunteer was converted to middle femoral comminuted fracture finite element analysis model. The fracture was fixated by NALCP and LCP. Stress distributions were observed. Under slow walking load and torsion load, the stress distribution tendency of the two plates was roughly uniform. The anterolateral femur was the tension stress area, and the bone block shifted toward the anterolateral femur. Maximum stress was found on the lateral border of the number 5 countersink of the plate. Under a slow walking load, the NALCP maximum stress was 2.160e+03 MPa and the LCP was 8.561e+02 MPa. Under torsion load, the NALCP maximum stress was 2.260e+03 MPa and the LCP was 6.813e+02 MPa. Based on those results of finite element analysis, the NALCP can provide adequate mechanical stability for comminuted fractures, which would help fixate the bone block and promote bone healing.

  7. Dating of cremated bones

    OpenAIRE

    Lanting, JN; Aerts-Bijma, AT; van der Plicht, J; Boaretto, E.; Carmi, I.

    2001-01-01

    When dating unburnt bone, bone collagen, the organic fraction of the bone, is used. Collagen does not survive the heat of the cremation pyre, so dating of cremated bone has been considered impossible. Structural carbonate in the mineral fraction of the bone, however, survives the cremation process. We developed a method of dating cremated bone by accelerator mass spectrometry (AMS), using this carbonate fraction. Here we present results for a variety of prehistoric sites and ages, showing a r...

  8. Post-Traumatic Caspase-3 Expression in the Adjacent Areas of Growth Plate Injury Site: A Morphological Study

    Science.gov (United States)

    Musumeci, Giuseppe; Castrogiovanni, Paola; Loreto, Carla; Castorina, Sergio; Pichler, Karin; Weinberg, Annelie Martina

    2013-01-01

    The epiphyseal plate is a hyaline cartilage plate that sits between the diaphysis and the epiphysis. The objective of this study was to determine the impact of an injury in the growth plate chondrocytes through the study of histological morphology, immunohistochemistry, histomorphometry and Western Blot analyses of the caspase-3 and cleaved PARP-1, and levels of the inflammatory cytokines, Interleukin-6 (IL-6) and Tumor Necrosis Factor alpha (TNF-α), in order to acquire more information about post-injury reactions of physeal cell turnover. In our results, morphological analysis showed that in experimental bones, neo-formed bone trabeculae—resulting from bone formation repair—invaded the growth plate and reached the metaphyseal bone tissue (bone bridge), and this could result in some growth arrest. We demonstrated, by ELISA, increased expression levels of the inflammatory cytokines IL-6 and TNF-α. Immunohistochemistry, histomorphometry and Western Blot analyses of the caspase-3 and cleaved PARP-1 showed that the physeal apoptosis rate of the experimental bones was significantly higher than that of the control ones. In conclusion, we could assume that the inflammation process causes stress to chondrocytes that will die as a biological defense mechanism, and will also increase the survival of new chondrocytes for maintaining cell homeostasis. Nevertheless, the exact stimulus leading to the increased apoptosis rate, observed after injury, needs additional research to understand the possible contribution of chondrocyte apoptosis to growth disturbance. PMID:23899790

  9. Post-Traumatic Caspase-3 Expression in the Adjacent Areas of Growth Plate Injury Site: A Morphological Study

    Directory of Open Access Journals (Sweden)

    Karin Pichler

    2013-07-01

    Full Text Available The epiphyseal plate is a hyaline cartilage plate that sits between the diaphysis and the epiphysis. The objective of this study was to determine the impact of an injury in the growth plate chondrocytes through the study of histological morphology, immunohistochemistry, histomorphometry and Western Blot analyses of the caspase-3 and cleaved PARP-1, and levels of the inflammatory cytokines, Interleukin-6 (IL-6 and Tumor Necrosis Factor alpha (TNF-α, in order to acquire more information about post-injury reactions of physeal cell turnover. In our results, morphological analysis showed that in experimental bones, neo-formed bone trabeculae—resulting from bone formation repair—invaded the growth plate and reached the metaphyseal bone tissue (bone bridge, and this could result in some growth arrest. We demonstrated, by ELISA, increased expression levels of the inflammatory cytokines IL-6 and TNF-α. Immunohistochemistry, histomorphometry and Western Blot analyses of the caspase-3 and cleaved PARP-1 showed that the physeal apoptosis rate of the experimental bones was significantly higher than that of the control ones. In conclusion, we could assume that the inflammation process causes stress to chondrocytes that will die as a biological defense mechanism, and will also increase the survival of new chondrocytes for maintaining cell homeostasis. Nevertheless, the exact stimulus leading to the increased apoptosis rate, observed after injury, needs additional research to understand the possible contribution of chondrocyte apoptosis to growth disturbance.

  10. A retrospective comparison of four plate constructs for first metatarsophalangeal joint fusion: static plate, static plate with lag screw, locked plate, and locked plate with lag screw.

    Science.gov (United States)

    Hyer, Christopher F; Scott, Ryan T; Swiatek, Michael

    2012-01-01

    The primary treatment for progressive first metatarsophalangeal (MTP) joint arthritis is arthrodesis. Multiple fixation types have been used to accomplish fusion including plating. There have been no published articles reporting the outcomes of these 4 plate and/or screw constructs. We present our experience with 138 first MTP joint fusions using these constructs. A retrospective comparison and radiographic chart review of 132 patients (138 feet) was performed to compare different constructs in regards to successful union and time to fusion. All operations were performed by 4 fellowship-trained foot and ankle surgeons. The radiographs were independently read by 2 authors not involved in the index procedures. Radiographic fusion was determined by bridging cortices across the joint line. The mean time to union (in days) and rate of fusion were static plate: 59, 95%, static plate with lag screw: 56, 86%, locked plate: 66, 92%, and locked plate with lag screw: 53, 96%. There was not a statistically significant difference between the groups in regards to patient age, time to weight bearing, time to fusion, or rate of fusion. We report on the results of fusion comparing 4 different plate and/or screw constructs for first MTP joint fusion. The data reveal no significant difference in time to fusion or rate of fusion between static and locked plates, with or without a lag screw. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Biomechanical properties of orthogonal plate configuration versus parallel plate configuration using the same locking plate system for intra-articular distal humeral fractures under radial or ulnar column axial load.

    Science.gov (United States)

    Kudo, Toshiya; Hara, Akira; Iwase, Hideaki; Ichihara, Satoshi; Nagao, Masashi; Maruyama, Yuichiro; Kaneko, Kazuo

    2016-10-01

    Previous reports have questioned whether an orthogonal or parallel configuration is superior for distal humeral articular fractures. In previous clinical and biomechanical studies, implant failure of the posterolateral plate has been reported with orthogonal configurations; however, the reason for screw loosening in the posterolateral plate is unclear. The purpose of this study was to evaluate biomechanical properties and to clarify the causes of posterolateral plate loosening using a humeral fracture model under axial compression on the radial or ulnar column separately. And we changed only the plate set up: parallel or orthogonal. We used artificial bone to create an Association for the Study of Internal Fixation type 13-C2.3 intra-articular fracture model with a 1-cm supracondylar gap. We used an anatomically-preshaped distal humerus locking compression plate system (Synthes GmbH, Solothurn, Switzerland). Although this is originally an orthogonal plate system, we designed a mediolateral parallel configuration to use the contralateral medial plate instead of the posterolateral plate in the system. We calculated the stiffness of the radial and ulnar columns and anterior movement of the condylar fragment in the lateral view. The parallel configuration was superior to the orthogonal configuration regarding the stiffness of the radial column axial compression. There were significant differences between the two configurations regarding anterior movement of the capitellum during axial loading of the radial column. The posterolateral plate tended to bend anteriorly under axial compression compared with the medial or lateral plate. We believe that in the orthogonal configuration axial compression induced more anterior displacement of the capitellum than the trochlea, which eventually induced secondary fragment or screw dislocation on the posterolateral plate, or nonunion at the supracondylar level. In the parallel configuration, anterior movement of the capitellum or

  12. Quantitative computed tomography as a test of endurance for evaluation of bony plates; Utilizacao da tomografia computadorizada quantitativa como teste de resistencia para avaliacao de placas osseas

    Energy Technology Data Exchange (ETDEWEB)

    Melo Filho, E.V.; Costa, L.A.V.S.; Oliveira, D.C. [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil); Freitas, P.M.C. [Escola de Veterinaria - Universidade Federal de Minas Gerais - Belo Horizonte, MG (Brazil); Teixeira, M.W.; Costa, F.S. [Universidade Federal Rural de Pernambuco - Recife, PE (Brazil)

    2012-06-15

    Quantitative computed tomography was used to determine the radiodensity of bony plates. The CT scans provided information regarding radiodensity of bony plates and allowed to verify the uniformity of bone mineral density in their scope. The proposed methodology should be considered as another tool for determining the resistance of these biomaterials. (author)

  13. Ex vivo cyclic mechanical behaviour of 2.4 mm locking plates compared with 2.4 mm limited contact plates in a cadaveric diaphyseal gap model.

    Science.gov (United States)

    Irubetagoyena, I; Verset, M; Palierne, S; Swider, P; Autefage, A

    2013-01-01

    To compare the mechanical properties of locking compression plate (LCP) and limited contact dynamic compression plate (LC-DCP) constructs in an experimental model of comminuted fracture of the canine femur during eccentric cyclic loading. A 20 mm mid-diaphyseal gap was created in eighteen canine femora. A 10-hole, 2.4 mm stainless steel plate (LCP or LC-DCP) was applied with three bicortical screws in each bone fragment. Eccentric cyclic loadings were applied at 10 Hertz for 610,000 cycles. Quasistatic loading / unloading cycles were applied at 0 and 10,000 cycles, and then every 50,000 cycles. Structural stiffness was calculated as the slope of the linear portion of the load-displacement curves during quasistatic loading / unloading cycles. No bone failure or screw loosening occurred. Two of the nine LCP constructs failed by plate breakage during fatigue testing, whereas no gross failure occurred with the LC-DCP constructs. The mean first stiffness of the LCP constructs over the course of testing was 24.0% lower than that of constructs stabilized by LC-DCP. Construct stiffness increased in some specimens during testing, presumably due to changes in bone-plate contact. The first stiffness of LC-DCP constructs decreased by 19.4% and that of locked constructs by 34.3% during the cycling period. A biphasic stiffness profile was observed: the second stiffness was significantly greater than the first stiffness in both groups, which allowed progressive stabilization at elevated load levels. Because LCP are not compressed to the bone, they may have a longer working length across a fracture, and thus be less stiff. However, this may cause them to be more susceptible to fatigue failure if healing is delayed.

  14. Delamination, upper plate extension, and plate margin complexity

    Science.gov (United States)

    Ueda, Kosuke; Gerya, Taras; Willett, Sean

    2017-04-01

    We investigate the syn- and post-subduction margin evolution with respect to extension, lithospheric removal, and magmatic and topographic consequences by employing 3D geodynamic models. In all experiments, regions of extended partial melting are overlain by up to 3 km high plateaus. There is complex geometric entanglement between upper mantle, partially molten rocks, and lithosphere, which is thermally eroded, over hundreds of kilometers across the plate contact. A complex lithosphere-asthenosphere-boundary features elongated anomalies at scales of few tens to hundred kilometers. First-order, synthetic seismic anomaly patterns, based on thermodynamic velocities which are tabulated for model p,T conditions, are accordingly complex. Passive margin geometry variations in the lower plate effect consistent and inherited differences in dynamic evolution. Promontories along the margin tend to trigger three stages of evolution: 1) a magmatic arc; 2) a lower plate, eduction-like exhumation of buried continental crust in domal patterns of few tens of km wavelength; and subsequently, 3) the formation of extended zones on the upper plate which lack a lithospheric mantle, undergo partial extension, and feature lower crustal melting. Slab break-off is consistently favoured in locations where the lower plate margin is relatively recessed. Concerning the classical removal mechanisms, transitions and co-evolution between delamination, convective thinning, and upper-plate extension are gradual and these modes are not mutually exclusive. Almost complete mixed-mode removal and extension can be compared to the Aegean. Slab window formation by margin geometry variation produces characteristic uplift patterns that are comparable to the Apennines, where higher uplift rates could be a consequence of incipient necking of the slab below central Calabria.

  15. Bone development

    DEFF Research Database (Denmark)

    Tatara, M.R.; Tygesen, Malin Plumhoff; Sawa-Wojtanowicz, B.

    2007-01-01

    The objective of this study was to determine the long-term effect of alpha-ketoglutarate (AKG) administration during early neonatal life on skeletal development and function, with emphasis on bone exposed to regular stress and used to serve for systemic changes monitoring, the rib. Shropshire ram...... at 146 days of life and five left and right ribs (fourth to eighth) were removed for analysis. The influence of AKG on skeletal system development was evaluated in relation to both geometrical and mechanical properties, as well as quantitative computed tomography (QCT). No significant differences between...... has a long-term effect on skeletal development when given early in neonatal life, and that changes in rib properties serve to improve chest mechanics and functioning in young animals. Moreover, neonatal administration of AKG may be considered as an effective factor enhancing proper development...

  16. Calcium phosphate cement augmentation after volar locking plating of distal radius fracture significantly increases stability.

    Science.gov (United States)

    Kainz, Hans; Dall'Ara, Enrico; Antoni, Anna; Redl, Heinz; Zysset, Philippe; Weninger, Patrick

    2014-08-01

    Distal radius fractures represent the most common fractures in adults. Volar locking plating to correct unstable fractures has become increasingly popular. Although reasonable primary reduction is possible in most cases, maintenance of reduction until the fracture is healed is often problematic in osteoporotic bone. To our knowledge, no biomechanical studies have compared the effect of enhancement with biomaterial on two different volar fixed-angle plates. Human fresh-frozen cadaver pairs of radii were used to simulate an AO/OTA 23-A3 fracture. In a total of four groups (n = 7 for each group), two volar fixed-angle plates (Aptus 2.5 mm locking fracture plate, Medartis, Switzerland and VA-LCP two-column distal radius plate 2.4, volar, Synthes, Switzerland) with or without an additional injection of a biomaterial (Hydroset Injectable HA Bone Substitute, Stryker, Switzerland) into the dorsal comminution zone were used to fix the distal metaphyseal fragment. Each specimen was tested load-controlled under cyclic loading with a servo-hydraulic material testing machine. Displacement, stiffness, dissipated work and failure mode were recorded. Improved mechanical properties (decreased displacement, increased stiffness, decreased dissipated work) were found in both plates if the biomaterial was additionally injected. Improvement of mechanical parameters after biomaterial injection was more evident in the Synthes plate compared to the Aptus plate. Pushing out of the screws was noticed as a failure mode only in samples lacking supplementary biomaterial. Injection of a biomaterial into the dorsal comminution zone increases stability after volar locking plating of distal radius fractures in vitro.

  17. Biomechanical Comparison of Intramedullary Screw Versus Low-Profile Plate Fixation of a Jones Fracture.

    Science.gov (United States)

    Huh, Jeannie; Glisson, Richard R; Matsumoto, Takumi; Easley, Mark E

    2016-04-01

    Intramedullary screw fixation of fifth metatarsal Jones fractures often produces satisfactory results, however, nonunion and refracture rates are not negligible. The low-profile "hook" plate is an alternative fixation method that has been promoted to offer improved rotational control at the fracture site, but this remains to be proven. The purpose of this study was to document biomechanical performance differences between this type of plate and a contemporary solid, dual-pitch intramedullary screw in a cadaveric Jones fracture model. Simulated Jones fractures were created in 8 matched pairs of fresh-frozen cadaveric fifth metatarsals. One bone from each pair was stabilized using an intramedullary TriMed Jones Screw and the other using a TriMed Jones Fracture Plate (TriMed, Inc, Santa Clarita, CA). Controlled bending and torsional loads were applied. Bending stiffness and fracture site angulation, as well as torsional stiffness, peak torque, and fracture site rotation were quantified and compared. Intramedullary screw fixation demonstrated greater bending stiffness and less fracture site angulation than plate fixation during plantar-to-dorsal and lateral-to-medial bending. Torsional stiffness of screw-fixed metatarsals exceeded that of plate-fixed bones at initial loading; however, as rotation progressed, the plate resisted torque better than the screw. No difference in peak torque was demonstrable between fixation methods, but it was reached earlier in specimens fixed with screws and later in those fixed with plates as rotation progressed. In this cadaveric Jones fracture model, intramedullary screw fixation demonstrated bending stiffness and resistance to early torsional loading that was superior to that offered by plate fixation. Although low-profile "hook" plates offer an alternative for fixation of fifth metatarsal Jones fractures, intramedullary screw fixation may provide better resistance to bending and initiation of fracture site rotation. The influence of

  18. Structural Analysis of Plate Based Tensegrity Structures

    DEFF Research Database (Denmark)

    Hald, Frederik; Kirkegaard, Poul Henning; Damkilde, Lars

    2013-01-01

    Plate tensegrity structures combine tension cables with a cross laminated timber plate and can then form e.g. a roof structure. The topology of plate tensegrity structures is investigated through a parametric investigation. Plate tensegrity structures are investigated, and a method...

  19. Use of savart plates in grating interferometers.

    Science.gov (United States)

    Peek, T H

    1971-05-01

    An analysis is given of Savart plates for arbitrary angles between the optic axis and the plate normal. Conoscopic interference patterns of thin Savart plates cut nearly parallel to the optic axis are shown and the use of such plates combined with diffraction gratings is discussed.

  20. Plating on some difficult-to-plate metals and alloys

    International Nuclear Information System (INIS)

    Dini, J.W.; Johnson, H.R.

    1980-02-01

    Electrodeposition of coatings on metals such as beryllium, beryllium-copper, Kovar, lead, magnesium, thorium, titanium, tungsten, uranium, zirconium, and their alloys can be problematic. This is due in most cases to a natural oxide surface film that readily reforms after being removed. The procedures we recommend for plating on these metals rely on replacing the oxide film with a displacement coating, or etching to allow mechanical keying between the substrate and plated deposit. The effectiveness of the procedures is demonstrated by interface bond strengths found in ring-shear and conical-head tensile tests

  1. Measurement of guided mode wavenumbers in soft tissue-bone mimicking phantoms using ultrasonic axial transmission.

    Science.gov (United States)

    Chen, Jiangang; Foiret, Josquin; Minonzio, Jean-Gabriel; Talmant, Maryline; Su, Zhongqing; Cheng, Li; Laugier, Pascal

    2012-05-21

    Human soft tissue is an important factor that influences the assessment of human long bones using quantitative ultrasound techniques. To investigate such influence, a series of soft tissue-bone phantoms (a bone-mimicking plate coated with a layer of water, glycerol or silicon rubber) were ultrasonically investigated using a probe with multi-emitter and multi-receiver arrays in an axial transmission configuration. A singular value decomposition signal processing technique was applied to extract the frequency-dependent wavenumbers of several guided modes. The results indicate that the presence of a soft tissue-mimicking layer introduces additional guided modes predicted by a fluid waveguide model. The modes propagating in the bone-mimicking plate covered by the soft-tissue phantom are only slightly modified compared to their counterparts in the free bone-mimicking plate, and they are still predicted by an elastic transverse isotropic two-dimensional waveguide. Altogether these observations suggest that the soft tissue-bone phantoms can be modeled as two independent waveguides. Even in the presence of the overlying soft tissue-mimicking layer, the modes propagating in the bone-mimicking plate can still be extracted and identified. These results suggest that our approach can be applied for the purpose of the characterization of the material and structural properties of cortical bone.

  2. Medial Column Arthrodesis Using an Anatomic Distal Fibular Locking Plate.

    Science.gov (United States)

    Nasser, Ellianne M; LaPorta, Guido A; Trott, Kasandra

    2015-01-01

    The medial column fusion is performed for a multitude of etiologies, including peritalar subluxation deformity, Charcot arthropathy, trauma, post-traumatic degenerative joint disease, and rheumatoid arthritis. Various surgical techniques have been described for medial column arthrodesis. We describe a new fixation method using an anatomic distal fibular locking plate for medial column arthrodesis. This technique provides a rigid construct in compromised or at risk bone. After a review of the surgical technique, we outline 2 case examples of patients with peritalar subluxation and Charcot arthropathy. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Stabilisation of periarticular fractures and osteotomies with a notched head locking T-plate.

    Science.gov (United States)

    Tan, C J; Johnson, K A

    2016-10-01

    To report the clinical outcomes and complications of small animals that had articular or periarticular fractures or osteotomies stabilised with a notched head locking T-plate. Medical records were searched retrospectively to identify animals that had a notched head locking T-plate used to stabilise a small articular or periarticular bone fragment. Nine dogs and two cats had an articular or periarticular bone fragment stabilised with a 2.0- or 2.4-mm notched head locking T-plate (12 procedures). The median body weight was 4.7 kg. The plate was modified by removing holes in 10/12 procedures and a combination of locking and non-locking screws were used in 7/12 procedures. All fractures or osteotomies progressed to clinical union. There were two intraoperative complications (intra-articular screw placement and overlong screw) and two postoperative complications (skin necrosis and stress protection) This study reports the successful use of a 2.0- or 2.4-mm notched head locking T-plate for articular or periarticular fractures or osteotomies in a variety of small-breed dogs and cats. Care must be taken to prevent inadvertent penetration of the articular surface, particularly in regions such as the proximal tibia. The ability to modify the plate dimensions intraoperatively proved beneficial in most cases. © 2016 Australian Veterinary Association.

  4. The mechanical benefit of medial support screws in locking plating of proximal humerus fractures.

    Directory of Open Access Journals (Sweden)

    Wen Zhang

    Full Text Available BACKGROUND: The purpose of this study was to evaluate the biomechanical advantages of medial support screws (MSSs in the locking proximal humeral plate for treating proximal humerus fractures. METHODS: Thirty synthetic left humeri were randomly divided into 3 subgroups to establish two-part surgical neck fracture models of proximal humerus. All fractures were fixed with a locking proximal humerus plate. Group A was fixed with medial cortical support and no MSSs; Group B was fixed with 3 MSSs but without medial cortical support; Group C was fixed with neither medial cortical support nor MSSs. Axial compression, torsional stiffness, shear stiffness, and failure tests were performed. RESULTS: Constructs with medial support from cortical bone showed statistically higher axial and shear stiffness than other subgroups examined (P<0.0001. When the proximal humerus was not supported by medial cortical bone, locking plating with medial support screws exhibited higher axial and torsional stiffness than locking plating without medial support screws (P ≤ 0.0207. Specimens with medial cortical bone failed primarily by fracture of the humeral shaft or humeral head. Specimens without medial cortical bone support failed primarily by significant plate bending at the fracture site followed by humeral head collapse or humeral head fracture. CONCLUSIONS: Anatomic reduction with medial cortical support was the stiffest construct after a simulated two-part fracture. Significant biomechanical benefits of MSSs in locking plating of proximal humerus fractures were identified. The reconstruction of the medial column support for proximal humerus fractures helps to enhance mechanical stability of the humeral head and prevent implant failure.

  5. Impact of Orthodontic Decompensation on Bone Insertion

    Science.gov (United States)

    Guedes, Fabio Pinto; Capelozza Filho, Leopoldino; Garib, Daniela Gamba; Nary Filho, Hugo; Borgo, Evandro José; Cardoso, Mauricio de Almeida

    2014-01-01

    There has always been concern in determining the relationship between orthodontic tooth movement and the consequent biological costs to the periodontium and tooth root. The possibility of evaluating the tooth and bone morphology by CBCT allows more accurate analysis of qualitative and quantitative aspects of these processes. This paper presents a case report of a 20-year-old male patient with Class III malocclusion and hyperdivergent facial pattern, who was surgically treated. A significant amount of labial movement of mandibular incisors was performed during orthodontic treatment before surgery. CBCT was used for evaluation of buccal and lingual bone plates before and after tooth decompensation. The changes in the bone insertion level of maxillary and mandibular incisors in the present case encourage a reflection on the treatment protocol in individuals with dentoskeletal discrepancies. PMID:25436157

  6. Impact of Orthodontic Decompensation on Bone Insertion

    Directory of Open Access Journals (Sweden)

    Fabio Pinto Guedes

    2014-01-01

    Full Text Available There has always been concern in determining the relationship between orthodontic tooth movement and the consequent biological costs to the periodontium and tooth root. The possibility of evaluating the tooth and bone morphology by CBCT allows more accurate analysis of qualitative and quantitative aspects of these processes. This paper presents a case report of a 20-year-old male patient with Class III malocclusion and hyperdivergent facial pattern, who was surgically treated. A significant amount of labial movement of mandibular incisors was performed during orthodontic treatment before surgery. CBCT was used for evaluation of buccal and lingual bone plates before and after tooth decompensation. The changes in the bone insertion level of maxillary and mandibular incisors in the present case encourage a reflection on the treatment protocol in individuals with dentoskeletal discrepancies.

  7. Bone-added periodontal plastic surgery: a new approach in esthetic dentistry.

    Science.gov (United States)

    Gholami, Gholam Ali; Gholami, Hadi; Amid, Reza; Kadkhodazadeh, Mahdi; Mehdizadeh, Amir Reza; Youssefi, Navid

    2015-01-01

    This article proposes a combined technique including bone grafting, connective tissue graft, and coronally advanced flap to create some space for simultaneous bone regrowth and root coverage. A 23 year-old female was referred to our private clinic with a severe class II Miller recession and lack of attached gingiva. The suggested treatment plan comprised of root coverage combined with xenograft bone particles. The grafted area healed well and full coverage was achieved at 12-month follow-up visit. Bone-added periodontal plastic surgery can be considered as a practical procedure for management of deep gingival recession without buccal bone plate.

  8. Permeability study of cancellous bone and its idealised structures.

    Science.gov (United States)

    Syahrom, Ardiyansyah; Abdul Kadir, Mohammed Rafiq; Harun, Muhamad Nor; Öchsner, Andreas

    2015-01-01

    Artificial bone is a suitable alternative to autografts and allografts, however their use is still limited. Though there were numerous reports on their structural properties, permeability studies of artificial bones were comparably scarce. This study focused on the development of idealised, structured models of artificial cancellous bone and compared their permeability values with bone surface area and porosity. Cancellous bones from fresh bovine femur were extracted and cleaned following an established protocol. The samples were scanned using micro-computed tomography (μCT) and three-dimensional models of the cancellous bones were reconstructed for morphology study. Seven idealised and structured cancellous bone models were then developed and fabricated via rapid prototyping technique. A test-rig was developed and permeability tests were performed on the artificial and real cancellous bones. The results showed a linear correlation between the permeability and the porosity as well as the bone surface area. The plate-like idealised structure showed a similar value of permeability to the real cancellous bones. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  9. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation.

    Science.gov (United States)

    Lujan, Trevor J; Henderson, Chris E; Madey, Steven M; Fitzpatrick, Dan C; Marsh, J Lawrence; Bottlang, Michael

    2010-03-01

    Locked plating constructs may be too stiff to reliably promote secondary bone healing. This study used a novel imaging technique to quantify periosteal callus formation of distal femur fractures stabilized with locking plates. It investigated the effects of cortex-to-plate distance, bridging span, and implant material on periosteal callus formation. Retrospective cohort study. One Level I and one Level II trauma center. Sixty-four consecutive patients with distal femur fractures (AO types 32A, 33A-C) stabilized with periarticular locking plates. Osteosynthesis using indirect reduction and bridge plating with periarticular locking plates. Periosteal callus size on lateral and anteroposterior radiographs. Callus size varied from 0 to 650 mm2. Deficient callus (20 mm2 or less) formed in 52%, 47%, and 37% of fractures at 6, 12, and 24 weeks postsurgery, respectively. Callus formation was asymmetric, whereby the medial cortex had on average 64% more callus (P=0.001) than the anterior or posterior cortices. A longer bridge span correlated minimally with an increased callus size at Week 6 (P=0.02), but no correlation was found at Weeks 12 and 24 postsurgery. Compared with stainless steel plates, titanium plates had 76%, 71%, and 56% more callus at Week 6 (P=0.04), Week 12 (P=0.03), and Week 24 (P=0.09), respectively. Stabilization of distal femur fractures with periarticular locking plates can cause inconsistent and asymmetric formation of periosteal callus. A larger bridge span only minimally improves callus formation. The more flexible titanium plates enhanced callus formation compared with stainless steel plates.

  10. A clinical, radiological and computational analysis of the thrust plate prosthesis in young patients.

    Science.gov (United States)

    Gerich, T G; Wilmes, P; Nackenhorst, U; Gösling, T; Ziefle, M; Krettek, C

    2011-01-01

    A thrust plate prosthesis can be used as an alternative to a conventional stem prosthesis, preserving the diaphyseal bone stock. Recent findings however predict a higher rate of aseptic loosening than with intramedullary devices. The purpose of our investigation was to compare the clinical outcome and radiological findings with a finite element analysis of bone remodeling. The hypothesis was that aseptic loosening after thrust plate prosthesis of the hip is inherent to the design. From 1997 to 2001, 58 thrust plates were implanted in 52 patients. Average age at the time of surgery was 40.9 years. Ninety four percent returned for follow up at an average of 26 months. A finite element model of the thrust plate within the femur was developed and stress shielding as well as bone remodeling were analyzed. A total of 4 patients required revision surgery (6.9%). Data from the finite element analysis revealed an inherent failure mechanism to the implant, facilitating stress shielding and loosening. Lacking the ideal total hip prosthesis in young patients, the thrust plate can still be regarded as a feasible implant. However, surgeons and patients should be aware of possible mechanical problems regarding the design of the thrust plate. There is evidence that thrust plate prostheses are prone to early aseptic loosening. Clinical and radiological observations are in agreement with the results from the numerical simulations. Stress concentrations computed at the leash are interpreted as an explanation for leash pain. The authors regard computational methods as an aid to improve existing prosthesis design and future developments.

  11. Intraosseous fixation compared to plantar plate fixation for first metatarsocuneiform arthrodesis: a cadaveric biomechanical analysis.

    Science.gov (United States)

    Roth, Klaus Edgar; Peters, Jennifer; Schmidtmann, Irene; Maus, Uwe; Stephan, Daniel; Augat, Peter

    2014-11-01

    Metatarsocuneiform (MTC) fusion is a treatment option for management of hallux valgus. We compared the biomechanical characteristics of an internal fixation device with plantar plate fixation. Seven matched pairs of feet from human cadavers were used to compare the intramedullary (IM) device plus compression screw to plantar plate combined with a compression screw. Specimen constructs were loaded in a cyclic 4-point bending test. We obtained initial/final stiffness, maximum load, and number of cycles to failure. Bone mineral density was measured with peripheral quantitative computed tomography. Performance was compared using time to event analysis with number of cycles as time variable, and a proportional hazard model including shared frailty model fitted with treatment and bone mineral density as covariates. On average the plates failed after 7517 cycles and a maximum load of 167 N, while the IM-implants failed on average after 2946 cycles and a maximum load of 69 N. In all pairs the 1 treated with IM-implant failed earlier than the 1 treated with a plate (hazard ratio for IM-implant versus plate was 79.9 (95% confidence interval [6.1, 1052.2], P = .0009). The initial stiffness was 131 N/mm for the plantar plate and 43.3 N/mm for the IM implant. Initial stiffness (r = .955) and final stiffness (r = .952) were strongly related to the number of cycles to failure. Bone mineral density had no effect on the number of cycles to failure. Plantar plate fixation created a stronger and stiffer construct than IM fixation. A stiffer construct can reduce the risk of nonunion and shorten the period of non-weight-bearing. © The Author(s) 2014.

  12. Fretting corrosion tests on orthopedic plates and screws made of ASTM F138 stainless steel

    Directory of Open Access Journals (Sweden)

    Claudio Teodoro dos Santos

    Full Text Available Introduction Although there has been significant progress in the design of implants for osteosynthesis, the occurrence of failures in these medical devices are still frequent. These implants are prone to suffer from fretting corrosion due to micromotion that takes place between the screw heads and plate holes. Consequently, fretting corrosion has been the subject of research in order to understand its influence on the structural integrity of osteosynthesis implants. The aim of this paper is to correlate the surface finish characteristics of bone plate-screw systems with fretting corrosion. Methods The surface finish (machined and polished of five specimens taken from three commercial dynamic compression plates (DCP were evaluated. For testing, the specimens were fixed with bone screws, immersed in a solution of 0.90% NaCl and subjected to a rocking motion with an amplitude of 1.70 mm and frequency of 1.0 Hz for 1.0 × 106 cycles, according to the ASTM F897 standard. Both, plate and screws were manufactured in Brazil with ASTM F138 stainless steel. Results Flaws on the hole countersink area and on the screw thread of some specimens were identified stereoscopically. At the end of the test all the specimens showed evidence of fretting corrosion with an average metal loss of 4.80 mg/million cycles. Conclusion An inadequate surface finish in some areas of the plates and screws may have favored the incidence of damage to the passive film, accelerating the fretting corrosion at the interfaces between the plate hole countersink and the screw head. Keywords Osteosynthesis, DCP, Bone plate, Screw, Fretting corrosion, Stainless steel.

  13. [The anatomical plates of Antommarchi].

    Science.gov (United States)

    Dumaitre, P

    1981-09-01

    Mascagni, professor of anatomy in Florence, died in the same town in 1815, leaving manuscripts and drawings for an intended publication of a comprehensive complete anatomy with life-size figures. His prosector, Antommarchi, prepared the publication but was meanwhile called to Saint Helena. He left, taking with him three copies of Mascagni's plates. When he returned, he published these plates, printed from lithographs, under his own name in a monumental work which appeared from 1823 to 1826 under the title of: Planches anatomiques du corps humain exécutées d'après les dimensions naturelles.

  14. The Photodynamic Bone Stabilization System: a minimally invasive, percutaneous intramedullary polymeric osteosynthesis for simple and complex long bone fractures.

    Science.gov (United States)

    Vegt, Paul; Muir, Jeffrey M; Block, Jon E

    2014-01-01

    The treatment of osteoporotic long bone fractures is difficult due to diminished bone density and compromised biomechanical integrity. The majority of osteoporotic long bone fractures occur in the metaphyseal region, which poses additional problems for surgical repair due to increased intramedullary volume. Treatment with internal fixation using intramedullary nails or plating is associated with poor clinical outcomes in this patient population. Subsequent fractures and complications such as screw pull-out necessitate additional interventions, prolonging recovery and increasing health care costs. The Photodynamic Bone Stabilization System (PBSS) is a minimally invasive surgical technique that allows clinicians to repair bone fractures using a light-curable polymer contained within an inflatable balloon catheter, offering a new treatment option for osteoporotic long bone fractures. The unique polymer compound and catheter application provides a customizable solution for long bone fractures that produces internal stability while maintaining bone length, rotational alignment, and postsurgical mobility. The PBSS has been utilized in a case series of 41 fractures in 33 patients suffering osteoporotic long bone fractures. The initial results indicate that the use of the light-cured polymeric rod for this patient population provides excellent fixation and stability in compromised bone, with a superior complication profile. This paper describes the clinical uses, procedural details, indications for use, and the initial clinical findings of the PBSS.

  15. Osteosynthesis in surgical treatment of metastatic lesions of long tubular bones

    OpenAIRE

    RADCHENKO A.I.; ZHUKOVEC A.G.; BOGDAEV Y.M.

    2017-01-01

    Objectives. This study was designed to investigate the causes and risk factors of complications requiring revision surgeries after intramedullary and plate osteosynthesis of the long tubular bones affected by metastases. Methods. Surgical treatment outcomes of patients with long tubular bones metastases (n=44) were analyzed retrospectively. Twelve patients had solitary skeletal metastasis, eleven multiple, twenty one bone metastases combined with visceral metastases. The pathological fracture...

  16. Bone grafting: An overview

    Directory of Open Access Journals (Sweden)

    D. O. Joshi

    2010-08-01

    Full Text Available Bone grafting is the process by which bone is transferred from a source (donor to site (recipient. Due to trauma from accidents by speedy vehicles, falling down from height or gunshot injury particularly in human being, acquired or developmental diseases like rickets, congenital defects like abnormal bone development, wearing out because of age and overuse; lead to bone loss and to replace the loss we need the bone grafting. Osteogenesis, osteoinduction, osteoconduction, mechanical supports are the four basic mechanisms of bone graft. Bone graft can be harvested from the iliac crest, proximal tibia, proximal humerus, proximal femur, ribs and sternum. An ideal bone graft material is biologically inert, source of osteogenic, act as a mechanical support, readily available, easily adaptable in terms of size, shape, length and replaced by the host bone. Except blood, bone is grafted with greater frequency. Bone graft indicated for variety of orthopedic abnormalities, comminuted fractures, delayed unions, non-unions, arthrodesis and osteomyelitis. Bone graft can be harvested from the iliac crest, proximal tibia, proximal humerus, proximal femur, ribs and sternum. By adopting different procedure of graft preservation its antigenicity can be minimized. The concept of bone banking for obtaining bone grafts and implants is very useful for clinical application. Absolute stability require for successful incorporation. Ideal bone graft must possess osteogenic, osteoinductive and osteocon-ductive properties. Cancellous bone graft is superior to cortical bone graft. Usually autologous cancellous bone graft are used as fresh grafts where as allografts are employed as an alloimplant. None of the available type of bone grafts possesses all these properties therefore, a single type of graft cannot be recomm-ended for all types of orthopedic abnormalities. Bone grafts and implants can be selected as per clinical problems, the equipments available and preference of

  17. Bone grafts in dentistry

    Directory of Open Access Journals (Sweden)

    Prasanna Kumar

    2013-01-01

    Full Text Available Bone grafts are used as a filler and scaffold to facilitate bone formation and promote wound healing. These grafts are bioresorbable and have no antigen-antibody reaction. These bone grafts act as a mineral reservoir which induces new bone formation.

  18. Bone scan in rheumatology

    International Nuclear Information System (INIS)

    Morales G, R.; Cano P, R.; Mendoza P, R.

    1993-01-01

    In this chapter a revision is made concerning different uses of bone scan in rheumatic diseases. These include reflex sympathetic dystrophy, osteomyelitis, spondyloarthropaties, metabolic bone diseases, avascular bone necrosis and bone injuries due to sports. There is as well some comments concerning pediatric pathology and orthopedics. (authors). 19 refs., 9 figs

  19. Bone Marrow Transplantation

    Science.gov (United States)

    Bone marrow is the spongy tissue inside some of your bones, such as your hip and thigh bones. It contains immature cells, called stem cells. The ... platelets, which help the blood to clot. A bone marrow transplant is a procedure that replaces a ...

  20. Wear and Mechanical Behaviour of Various Polymethylmethacrylate Bone Cements

    Czech Academy of Sciences Publication Activity Database

    Balko, J.; Ballóková, B.; Jakubéczyová, D.; Hvizdoš, P.; Hloch, Sergej; Kloc, J.; Monka, P.

    2013-01-01

    Roč. 13, č. 1 (2013), s. 34-43 ISSN 1335-8987 Institutional support: RVO:68145535 Keywords : bone cements * mixing * pin-on-plate * porosity * nano-hardness Subject RIV: JQ - Machines ; Tools http://www.imr.saske.sk/pmp/issue/1-2013/PMP_Vol13_No1_p_034-043.pdf

  1. Mechanical stimulation of bone cells using fluid flow

    NARCIS (Netherlands)

    Huesa, C.; Bakker, A.D.

    2012-01-01

    This chapter describes several methods suitable for mechanically stimulating monolayers of bone cells by fluid shear stress (FSS) in vitro. Fluid flow is generated by pumping culture medium through two parallel plates, one of which contains a monolayer of cells. Methods for measuring nitric oxide

  2. A Biomechanical Comparison of Locking Versus Conventional Plate Fixation for Distal Fibula Fractures in Trimalleolar Ankle Injuries.

    Science.gov (United States)

    Nguyentat, Annie; Camisa, William; Patel, Sandeep; Lagaay, Pieter

    2016-01-01

    Previous biomechanical studies have advocated the use of locking plates for isolated distal fibula fractures in osteoporotic bone. Complex rotational ankle injuries involve an increased number of fractures, which can result in instability, potentially requiring the same fixed angle properties afforded by locking plates. However, the mechanical indication for locking plate technology has not been tested in this fracture model. The purpose of the present study was to compare the biomechanical properties of locking and conventional plate fixation for distal fibula fractures in trimalleolar ankle injuries. Fourteen (7 matched pairs) fresh-frozen cadaver leg specimens were used. The bone mineral density of each was obtained using dual x-ray absorptiometry scans. The fracture model simulated an OTA 44-B3.3 fracture. The syndesmosis was not disrupted. Each fracture was fixated in the same fashion, except for the distal fibula plate construct: locking (n = 7) and one-third tubular (n = 7). The specimens underwent axial and torsional cyclic loading, followed by torsional loading to failure. No statistically significant differences were found between the locking and conventional plate constructs during both fatigue and torque to failure testing (p > .05). Our specimen bone mineral density averages did not represent poor bone quality. The clinical implication of the present study is that distal fibular locking plates do not provide a mechanical advantage for trimalleolar ankle injuries in individuals with normal bone density and in the absence of fracture comminution. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Radionuclide assessment of skeletal growth and maturation (160 bone scans)

    International Nuclear Information System (INIS)

    Guillet, J.; Blanquet, P.; Guillet, C.

    1982-01-01

    Increases in blood supply, and certain metabolic and physical processes, are of special significance in epiphyseal growth centers. Such events are evidenced by the uptake of sup(99m)Tc methylenes diphosphonate (MDP). Bone scans in children and young adults show increased radionuclide uptake in epiphyseal growth plates. Age-related changes in sup(99m)Tc MDP epiphyseal uptake can be used for determining a functional bone age. Radiation exposure is within the range of other routine diagnostic procedures. Scanning was done with a gamma scintillation camera, which supplys rapid, high resolution, studies. In the first five years of life, nearly all the main epiphyseal growth plates were visible symmetrically on routine scans. In six cases, growth plates were visible before the corresponding epiphyseal ossification foci became apparent on roentgenograms. Little bones (hands, wrists, feet, and ankles) were not assessed because of the poor resolution of the parallel collimator-camera system. A slow decrease in epiphyseal growth plate activity was demonstrated in subjects over sixteen years of age. In some instances, this decrease occurred only after epiphyseal closure became visible on roentgenograms. Data described here are not usually employed for clinical purposes, except when viability of a growth plate is doubtful. Functional analysis with sup(99m)Tc MDP is a useful complement to roentgenologic investigation of skeletal growth and maturation [fr

  4. Bone changes caused by experimental Solanum malacoxylon poisoning in rabbits

    Directory of Open Access Journals (Sweden)

    José Ignacio Aguirre

    2005-03-01

    Full Text Available The aim of this study was to describe the bone changes observed after a daily oral administration of the calcinogenic plant Solanum malacoxylon (syn. S. glaucophyllum (Sm during 9 days. The Sm-poisoned rabbits had an increase of bone resorption in the endosteal surface of the cortical zone and also in the surface covered by osteoblasts of the primary and secondary spongiosa of the trabecular bone compartment. Moreover, the epiphyseal growth plates in long bones appeared narrower than in the control rabbits, with reduction of the proliferative and hyperthrophic chondrocyte zones. The electron microscopic study revealed a significant decrease of proteoglycans in the hyperthrophic chondrocyte zone evidenced by a significant reduction of rutenium red positive granules in the poisoned rabbit. Altogether, these data suggest that cell differentiation may play a pivotal role in the pathogenesis of Sm-induced bone lesions.

  5. Seismic link at plate boundary

    Indian Academy of Sciences (India)

    transfer between two major faults, and parallel to the geothermal area extension. 1. Introduction. Plate boundaries are the zones where most earth dynamics are focussed. The complexity of tectonic boundaries draws attention to them as the largest earthquakes are felt in these areas and they elicit the natural hazard of ...

  6. Seismic link at plate boundary

    Indian Academy of Sciences (India)

    ... tested using the coherence of time series to determine the causality and related orientation. The resulting link orientations at the plate boundary conditions indicate that causal triggering seems to be localized along a major fault, as a stress transfer between two major faults, and parallel to the geothermal area extension.

  7. OUTCOME OF LOCKING PLATES IN DISTAL TIBIA FRACTURES TREATMENT

    Directory of Open Access Journals (Sweden)

    Lokesh

    2016-05-01

    (22% 4 patients for which secondary surgery with bone grafting procedure was done after 4 months. According to AOFAS, 7 we scored the functional outcome of the patients after 5 months of injury. We had 23% of excellent result, 30.4% good and 46% fair with plate. CONCLUSION Locking anatomical plates are a boon and have started a new era in orthopaedic surgery in fixation with articular fractures. But due to lack of locking plate principle it is again cumbersome. Locking plates give relative stability for fracture and need as much as possible anatomical reduction of articular margins unlike in nail where we can do dynamisation if fracture going for delayed union in locking plates is not possible, hence doing as much as possible fracture alignment and then stabilising the fracture with screws is recommended.

  8. Anorexia Nervosa and Bone

    Science.gov (United States)

    Misra, Madhusmita; Klibanski, Anne

    2014-01-01

    Anorexia nervosa (AN) is a condition of severe low weight that is associated with low bone mass, impaired bone structure and reduced bone strength, all of which contribute to increased fracture risk., Adolescents with AN have decreased rates of bone accrual compared with normal-weight controls, raising addition concerns of suboptimal peak bone mass and future bone health in this age group. Changes in lean mass and compartmental fat depots, hormonal alterations secondary to nutritional factors contribute to impaired bone metabolism in AN. The best strategy to improve bone density is to regain weight and menstrual function. Oral estrogen-progesterone combinations are not effective in increasing bone density in adults or adolescents with AN, and transdermal testosterone replacement is not effective in increasing bone density in adult women with AN. However, physiologic estrogen replacement as transdermal estradiol with cyclic progesterone does increase bone accrual rates in adolescents with AN to approximate that in normal-weight controls, leading to a maintenance of bone density Z-scores. A recent study has shown that risedronate increases bone density at the spine and hip in adult women with AN. However, bisphosphonates should be used with great caution in women of reproductive age given their long half-life and potential for teratogenicity, and should be considered only in patients with low bone density and clinically significant fractures when non-pharmacological therapies for weight gain are ineffective. Further studies are necessary to determine the best therapeutic strategies for low bone density in AN. PMID:24898127

  9. Operational test of bonded magnetocaloric plates

    DEFF Research Database (Denmark)

    Bahl, Christian; Navickaité, Kristina; Neves Bez, Henrique

    2017-01-01

    Bonded plates made by hot pressing La0.85Ce0.15Fe11.25Mn0.25Si1.5Hy particles and resin have been tested as active magnetic regenerators in a small scale magnetocaloric device. Firstly the plates were carefully characterised magnetically and thermally. The plates were prepared with 5 wt% resin......, and from density measurements it was found that the volume ratio of the magnetocaloric material in the plates was 0.53, due to the resin and porosity. The best operating conditions for the plate regenerator were determined at which a temperature span of 6.4 K was measured along the plates....

  10. Extraction of gadolinium from high flux isotope reactor control plates

    International Nuclear Information System (INIS)

    Kohring, M.W.

    1987-04-01

    Gadolinium-153 is an important radioisotope used in the diagnosis of various bone disorders. Recent medical and technical developments in the detection and cure of osteoporosis, a bone disease affecting an estimated 50 million people, have greatly increased the demand for this isotope. The Oak Ridge National Laboratory (ORNL) has produced 153 Gd since 1980 primarily through the irradiation of a natural europium-oxide powder followed by the chemical separation of the gadolinium fraction from the europium material. Due to the higher demand for 153 Gd, an alternative production method to supplement this process has been investigated. This process involves the extraction of gadolinium from the europium-bearing region of highly radioactive, spent control plates used at the High Flux Isotope Reactor (HFIR) with a subsequent re-irradiation of the extracted material for the production of the 153 Gd. Based on the results of experimental and calculational analyses, up to 25 grams of valuable gadolinium (≥60% enriched in 152 Gd) resides in the europium-bearing region of the HFIR control components of which 70% is recoverable. At a specific activity yield of 40 curies of 153 Gd for each gram of gadolinium re-irradiated, 700 one-curie sources can be produced from each control plate assayed

  11. Use of a locking plate “notched head T-plate®” for the fixation of an ilial body fracture in a dog

    Directory of Open Access Journals (Sweden)

    Cassio Ricardo Auada Ferrigno

    2016-10-01

    Full Text Available Several types of implants may be used to treat iliac fractures in dogs, of which osteosynthesis with plate is the most described and recommended in the literature. The type of plate and screw are major factors in osteosynthesis success. The use of locking plates has been advocated for this purpose, as they do not allow the plate-bone-screw unit to shift, providing angular stability and rigidity to the system. The present study aimed to describe the unprecedented use of a locking notched head T-plate in the treatment of a caudal body of ilium fracture. A two year old male mongrel dog was attended after falling from a third floor height, with two days of evolution. The animal was in standing position, and during orthopedic examination non-weight bearing lameness of the right hind limb, instability, and crepitus in the right body of ilium, with considerable swelling and pain. The radiographic examination allowed diagnosing a complete fracture of the caudal body of ilium with decrease of the pelvic canal diameter. The patient underwent surgery, and the fracture was stabilized with an LCP notched head T-plate. The patient evolved satisfactorily, with good weight-bearing of the affected limb within 24 hours of surgery, and complete recovery with medical discharge after 60 days of postoperative period, with consolidation of the fracture.

  12. [Management of facial bone fractures].

    Science.gov (United States)

    Oikarinen, Kyösti; Korpi, Jarkko

    2010-01-01

    Although the number of patients suffering from facial bone fractures has decreased more resources due to complexity of the fractures are needed. The initial treatment and reconstruction phase require hospitalisation and close collaboration between several medical and dental specialists. Fractures cause alterations in occlusion and masticatory functions and are frequently associated with soft tissue injuries. The primary radiographic examination is panoramic radiography in mandibular and computed tomography in maxillary and mid face fractures. The treatment principles have changed during the last three decades. Long-term maxillomandibular immobilisation has given way to internal fixation and direct osteosynthesis. The greatest innovations of the treatment have taken place in materials. Steel has been replaced by Titanium or resorbable plates, screws and meshes.

  13. Rheology of acrylic bone cements.

    Science.gov (United States)

    Ferracane, J L; Greener, E H

    1981-01-01

    The rheological properties of setting acrylic bone cements were examined with a rotational cone and plate viscometer. The cements were tested over two orders of magnitude of shear rate to determine the nature of any non-Newtonian flow behavior. All three cements behaved with moderate pseudoplasticity (i.e., shear thinning) during setting, suggesting the use of higher pressures during administration for better flow and penetration. The low viscosity brand was found to be nearly one-half as viscous as the conventional cements during the working time (i.e., 2-5 minutes). A series of sieving experiments were performed to determine the particle size distributions of the powder components. Statistical analysis (chi square) showed the cements to have different distributions, with the low viscosity brand containing a larger proportion of smaller polymer particles. This difference is thought to contribute to the lower viscosity of this cement.

  14. A comparative study on the customized design of mandibular reconstruction plates using finite element method

    Directory of Open Access Journals (Sweden)

    Abdulrahman Al-Ahmari

    2015-07-01

    Full Text Available Mandible defects and its deformities are serious complications and its precise reconstruction is one of the most challenging tasks in oral maxillofacial surgery. The commercially available standard mandible implants are manually bended before surgery to custom fit the patient’s jaw. A slight mismatch in the plate and bone alignment may result in the implant failure. However, with the integration of computer-aided design, rapid prototyping, and advanced imaging systems (computed tomography or magnetic resonance imaging, it is possible to produce a customized mandible implant that can precisely fit the patient’s jaw. The aim of this article is to compare a new design of customized mandible implant (sinewave plate and compare it with the commonly used straight implant design. The finite element–simulated results reveal that the commonly used straight reconstruction plates are more prone to loosening of the screws due to its higher strain concentration on the screw hole when compared to newly designed sinewave reconstruction plate. Moreover, the straight plate is more sensitive to the chewing load variations and develops almost 20% increase in the stresses when compared to sinewave plate. The study reveals that the sinewave reconstruction plate can significantly enhance the stability and safety of the mandible implant.

  15. Regulation of Bone Metabolism

    Directory of Open Access Journals (Sweden)

    Maryam Shahi

    2017-05-01

    Full Text Available Bone is formed through the processes of endochondral and intramembranous ossification. In endochondral ossification primary mesenchymal cells differentiate to chondrocytes and then are progressively substituted by bone, while in intramembranous ossification mesenchymal stem cells (MSCs differentiate directly into osteoblasts to form bone. The steps of osteogenic proliferation, differentiation, and bone homeostasis are controlled by various markers and signaling pathways. Bone needs to be remodeled to maintain integrity with osteoblasts, which are bone-forming cells, and osteoclasts, which are bone-degrading cells. In this review we considered the major factors and signaling pathways in bone formation; these include fibroblast growth factors (FGFs, bone morphogenetic proteins (BMPs, wingless-type (Wnt genes, runt-related transcription factor 2 (RUNX2 and osteoblast-specific transcription factor (osterix or OSX.

  16. Bone disease in hypoparathyroidism.

    Science.gov (United States)

    Clarke, Bart L

    2014-07-01

    Hypoparathyroidism is a rare disorder that may be acquired or inherited. Postsurgical hypoparathyroidism is responsible for the majority of acquired hypoparathyroidism. Bone disease occurs in hypoparathyroidism due to markedly reduced bone remodeling due to the absence or low levels of parathyroid hormone. Chronically reduced bone turnover in patients with hypoparathyroidism typically leads to higher bone mass than in age- and sex-matched controls. Whether this increased bone density reduces fracture risk is less certain, because while increased bone mineralization may be associated with increased brittleness of bone, this does not appear to be the case in hypoparathyroidism. Treatment of hypoparathyroidism with recombinant parathyroid hormone may reduce bone mineral density but simultaneously strengthen the mechanical properties of bone.

  17. Black bone syndrome in chiken meat

    Directory of Open Access Journals (Sweden)

    GAA Baldo

    2013-12-01

    Full Text Available Black bone syndrome (BBS affects poultry industry, and it is caused by the darkening of the tissue adjacent to the bone due to leak age of bone marrow contents during cooking. The objective of this experiment was to estimate BBS incidence in chicken thighs. A completely randomized experimental design, with two treatments (refrigerated or frozen of 50 replicates each, was applied. The influence of BBS on meat quality was assessed according to bone lightness (*L, and meat appearance and sensorial characteristics. Lightness was measured using a colorimeter (Minolta® 410R positioned on the proximal epiphyseal growth plate. Meat quality was evaluated after roasting by assigning scores for appearance (acceptable = no darkening, intermediate = little darkened, and unacceptable = severe darkening. Twelve refrigerated and 12 frozen thighs were used for sensorial analysis (adjacent muscle appearance, odor, tenderness, and flavor, assessed using a hedonic scale (1 = bad to 10 = very good by trained panelists. Lightness was submitted to ANOVA and Tukey's test (p37.5=normal. The incidence of BBS was 35%,with a 16%increase thighs were frozen. Meat taste was not influenced by the treatments. Meat appearance, flavor, and tenderness were not affected by freezing or refrigeration, only by BBS degree. It was concluded that freezing increases the incidence of BBS and chicken thighs with bones presenting lower luminosity have worse meat quality.

  18. Bone-Immune Cell Crosstalk: Bone Diseases

    Directory of Open Access Journals (Sweden)

    Giorgio Mori

    2015-01-01

    Full Text Available Bone diseases are associated with great morbidity; thus, the understanding of the mechanisms leading to their development represents a great challenge to improve bone health. Recent reports suggest that a large number of molecules produced by immune cells affect bone cell activity. However, the mechanisms are incompletely understood. This review aims to shed new lights into the mechanisms of bone diseases involving immune cells. In particular, we focused our attention on the major pathogenic mechanism underlying periodontal disease, psoriatic arthritis, postmenopausal osteoporosis, glucocorticoid-induced osteoporosis, metastatic solid tumors, and multiple myeloma.

  19. The Thrust Plate Prosthesis: long-term clinical and radiological results.

    Science.gov (United States)

    Diederix, Leon W; Van Winterswijk, Peter J T S; Schouten, Sander B; Bakx, Pieter A G M; Huij, Jaap

    2013-06-01

    The Thrust Plate Prosthesis is a femoral implant designed for total hip arthroplasty, based on the principles of physiologic loading of the metaphysis of the proximal femur, and preserving the bone stock. This study presents the long-term clinical and radiological results of 34 patients with 36 Thrust Plate Prostheses. In a retrospective analysis, we investigated the reoperation-free survival as well as the clinical and radiological results. Mean age at operation was 51 +/- 6.4 years. Mean follow-up length was 11.9 +/- 1.6 years. Reoperation-free survival was 88.9%. Four (11.1%) reoperations were performed, in three patients due to aseptic loosening and in one patient because of a fracture distal to the lateral plate. Three of the reoperations were performed between 12 and 32 months postoperatively. The major complaint was pain at the lateral side of the hip (44%). Radiolucencies did not exceed 1 mm, but 35% of the hips showed resorption of the cortex directly under the thrust plate, together with cancellous bone hypertrophy at the calcar, noted in 97%. Because of the relatively high reoperation-free survival and favourable radiological results, the Thrust Plate Prosthesis appears as a possible alternative to stemmed total hip arthroplasty, especially in relatively young patients.

  20. Fibroblast growth factor receptor 3 effects on proliferation and telomerase activity in sheep growth plate chondrocytes

    Directory of Open Access Journals (Sweden)

    Smith Logan B

    2012-12-01

    Full Text Available Abstract Background Fibroblast growth factor receptor 3 (FGFR3 inhibits growth-plate chondrocyte proliferation and limits bone elongation. Gain-of-function FGFR3 mutations cause dwarfism, reduced telomerase activity and shorter telomeres in growth plate chondroyctes suggesting that FGFR3 reduces proliferative capacity, inhibits telomerase, and enhances senescence. Thyroid hormone (T3 plays a role in cellular maturation of growth plate chondrocytes and a known target of T3 is FGFR3. The present study addressed whether reduced FGFR3 expression enhanced telomerase activity, mRNA expression of telomerase reverse transcriptase (TERT and RNA component of telomerase (TR, and chondrocyte proliferation, and whether the stimulation of FGFR3 by T3 evoked the opposite response. Results Sheep growth-plate proliferative zone chondrocytes were cultured and transfected with siRNA to reduce FGFR3 expression; FGFR3 siRNA reduced chondrocyte FGFR3 mRNA and protein resulting in greater proliferation and increased TERT mRNA expression and telomerase activity (p 3 significantly enhanced FGFR3 mRNA and protein expression and reduced telomerase activity (p 3 at the growth plate may be partially mediated through the FGFR3 pathway. Conclusions The results suggest that FGFR3 inhibits chondrocyte proliferation by down-regulating TERT expression and reducing telomerase activity indicating an important role for telomerase in sustaining chondrocyte proliferative capacity during bone elongation.

  1. Synthesis and ultrastructure of plate-like apatite single crystals as a model for tooth enamel

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Zhi, E-mail: zhuang@meiji.ac.jp [Department of Applied Chemistry, School of Science and Technology, Meiji University, 1-1-1 Higashimita, Tama-ku, Kawasaki, Kanagawa 214-8571 (Japan); Yoshimura, Hideyuki, E-mail: hyoshi@isc.meiji.ac.jp [Department of Physics, School of Science and Technology, Meiji University, 1-1-1 Higashimita, Tama-ku, Kawasaki, Kanagawa 214-8571 (Japan); Aizawa, Mamoru, E-mail: mamorua@isc.meiji.ac.jp [Department of Applied Chemistry, School of Science and Technology, Meiji University, 1-1-1 Higashimita, Tama-ku, Kawasaki, Kanagawa 214-8571 (Japan)

    2013-07-01

    Hydroxyapatite (HAp) is an inorganic constituent compound of human bones and teeth, with superior biocompatibility and bioactivity characteristics. Its crystal structure is hexagonal, characterized by a(b)- and c-planes. In vertebrate long bones, HAp crystals have a c-axis orientation, while in tooth enamel, they have an a(b)-axis orientation. Many methods can be used to synthesize c-axis oriented HAp single crystals; however, to the best of our knowledge, there have been no reports on a synthesis method for a(b)-axis oriented HAp single crystals. In this study, we successfully synthesized plate-like HAp crystals at the air–liquid interface of a starting solution via an enzyme reaction of urea with urease. Crystal phase analysis and ultrastructure observations were carried out, and the results indicated that the particles were single crystals, with almost the same a(b)-axis orientation as tooth enamel. It is hoped that by utilizing their unique surface charge and atomic arrangement, the resulting particles can be used as a high-performance biomaterial, capable of adsorbing bio-related substances and a model for tooth enamel. - Highlights: ► Synthesis of plate-like hydroxyapatite crystals at air–liquid interface ► Ultrastructural analysis of plate-like hydroxyapatite crystals ► Plate-like hydroxyapatite single crystals with a high a(b)-axis orientation ► Plate-like hydroxyapatite single crystals as a model for tooth enamel.

  2. Purity test for copper-plating solutions

    Science.gov (United States)

    Mansfeld, F. B.

    1977-01-01

    Electrode configuration can be used to measure extent of impurities in acid-copper plating solution. It can be inserted into any plating tank and will show whether bath is clean or contaminated, within fifteen minutes.

  3. Earth's Decelerating Tectonic Plates

    Energy Technology Data Exchange (ETDEWEB)

    Forte, A M; Moucha, R; Rowley, D B; Quere, S; Mitrovica, J X; Simmons, N A; Grand, S P

    2008-08-22

    Space geodetic and oceanic magnetic anomaly constraints on tectonic plate motions are employed to determine a new global map of present-day rates of change of plate velocities. This map shows that Earth's largest plate, the Pacific, is presently decelerating along with several other plates in the Pacific and Indo-Atlantic hemispheres. These plate decelerations contribute to an overall, globally averaged slowdown in tectonic plate speeds. The map of plate decelerations provides new and unique constraints on the dynamics of time-dependent convection in Earth's mantle. We employ a recently developed convection model constrained by seismic, geodynamic and mineral physics data to show that time-dependent changes in mantle buoyancy forces can explain the deceleration of the major plates in the Pacific and Indo-Atlantic hemispheres.

  4. Maps, Plates, and Mount Saint Helens.

    Science.gov (United States)

    Lary, Barbara E.; Krockover, Gerald H.

    1987-01-01

    Describes a laboratory activity on plate tectonics which focuses on the connection between plate tectonics and the different types of volcanoes. Provides questions for discussion and includes suggestions for extending the activity. (ML)

  5. [Complex reconstruction with internal locking plate fixation for Charcot arthropathy].

    Science.gov (United States)

    Ramadani, F; Härägus, H; Radu, P; Trieb, K; Hofstaetter, S

    2015-01-01

    Osteosynthesis and reposition of the Charcot foot is challenging with respect to choice of a proper implant. There is currently no international consensus regarding the optimal implant. Locking plates seem to be an innovative and stable method for reconstruction. The aim of this work is to analyze bone fusion, complications, pseudoarthrosis, and patient satisfaction. This paper presents a retrospective analysis of 63 consecutive Charcot feet treated between 2004 and 2014. The mean follow-up time was 2.4 years. All Charcot feet treated between 2004 and 2014 were Sanders type II or III. A bony fusion was achieved in 50 % of the cases, 26 % had a functional pseudoarthrosis with intact implants and pain-free mobility, and 22 % showed no healing with broken implants. Conclusion Internal fixation with locking plates is superior to screw fixation only with regard to biomechanics. We prefer internal fixation plates to external fixation because of stability even in the case of pseudoathrosis and because of the learning curve.

  6. Epiphyseal abnormalities, trabecular bone loss and articular chondrocyte hypertrophy develop in the long bones of postnatal Ext1-deficient mice.

    Science.gov (United States)

    Sgariglia, Federica; Candela, Maria Elena; Huegel, Julianne; Jacenko, Olena; Koyama, Eiki; Yamaguchi, Yu; Pacifici, Maurizio; Enomoto-Iwamoto, Motomi

    2013-11-01

    Long bones are integral components of the limb skeleton. Recent studies have indicated that embryonic long bone development is altered by mutations in Ext genes and consequent heparan sulfate (HS) deficiency, possibly due to changes in activity and distribution of HS-binding/growth plate-associated signaling proteins. Here we asked whether Ext function is continuously required after birth to sustain growth plate function and long bone growth and organization. Compound transgenic Ext1(f/f);Col2CreERT mice were injected with tamoxifen at postnatal day 5 (P5) to ablate Ext1 in cartilage and monitored over time. The Ext1-deficient mice exhibited growth retardation already by 2weeks post-injection, as did their long bones. Mutant growth plates displayed a severe disorganization of chondrocyte columnar organization, a shortened hypertrophic zone with low expression of collagen X and MMP-13, and reduced primary spongiosa accompanied, however, by increased numbers of TRAP-positive osteoclasts at the chondro-osseous border. The mutant epiphyses were abnormal as well. Formation of a secondary ossification center was significantly delayed but interestingly, hypertrophic-like chondrocytes emerged within articular cartilage, similar to those often seen in osteoarthritic joints. Indeed, the cells displayed a large size and round shape, expressed collagen X and MMP-13 and were surrounded by an abundant Perlecan-rich pericellular matrix not seen in control articular chondrocytes. In addition, ectopic cartilaginous outgrowths developed on the lateral side of mutant growth plates over time that resembled exostotic characteristic of children with Hereditary Multiple Exostoses, a syndrome caused by Ext mutations and HS deficiency. In sum, the data do show that Ext1 is continuously required for postnatal growth and organization of long bones as well as their adjacent joints. Ext1 deficiency elicits defects that can occur in human skeletal conditions including trabecular bone loss

  7. Mathematical methods for elastic plates

    CERN Document Server

    Constanda, Christian

    2014-01-01

    Mathematical models of deformation of elastic plates are used by applied mathematicians and engineers in connection with a wide range of practical applications, from microchip production to the construction of skyscrapers and aircraft. This book employs two important analytic techniques to solve the fundamental boundary value problems for the theory of plates with transverse shear deformation, which offers a more complete picture of the physical process of bending than Kirchhoff’s classical one.   The first method transfers the ellipticity of the governing system to the boundary, leading to singular integral equations on the contour of the domain. These equations, established on the basis of the properties of suitable layer potentials, are then solved in spaces of smooth (Hölder continuous and Hölder continuously differentiable) functions.   The second technique rewrites the differential system in terms of complex variables and fully integrates it, expressing the solution as a combination of complex ana...

  8. Smaller plates, less food waste

    DEFF Research Database (Denmark)

    Hansen, Pelle Guldborg; Schmidt, Karsten; Skov, Laurits Rhoden

    and producers. Northern European consumers are among the most environmentally concerned consumers, however, their concerns do not always translate in more sustainable food-related behaviours. Furthermore, food choices are not always rational and could be non-reflective. Hence, the objective of this pilot study....... All food waste was collected in designated trash bags (different colour in each floor) and weighted in bulk by students. Smaller plates appear to have decreased food waste by 26% compared to the standard sized plates at a single serving in a self-service eating setting. This pilot study supports......With roughly one-third of food produced for human consumption lost or wasted globally (about 1.3 billion tons per year), the impact on the environment cannot be anymore neglected. Actions at all points in the production chain are now urgent, including reductions in food waste at home, by retailers...

  9. Role of Galectin-3 in Bone Cell Differentiation, Bone Pathophysiology and Vascular Osteogenesis

    Directory of Open Access Journals (Sweden)

    Carla Iacobini

    2017-11-01

    Full Text Available Galectin-3 is expressed in various tissues, including the bone, where it is considered a marker of chondrogenic and osteogenic cell lineages. Galectin-3 protein was found to be increased in the differentiated chondrocytes of the metaphyseal plate cartilage, where it favors chondrocyte survival and cartilage matrix mineralization. It was also shown to be highly expressed in differentiating osteoblasts and osteoclasts, in concomitance with expression of osteogenic markers and Runt-related transcription factor 2 and with the appearance of a mature phenotype. Galectin-3 is expressed also by osteocytes, though its function in these cells has not been fully elucidated. The effects of galectin-3 on bone cells were also investigated in galectin-3 null mice, further supporting its role in all stages of bone biology, from development to remodeling. Galectin-3 was also shown to act as a receptor for advanced glycation endproducts, which have been implicated in age-dependent and diabetes-associated bone fragility. Moreover, its regulatory role in inflammatory bone and joint disorders entitles galectin-3 as a possible therapeutic target. Finally, galectin-3 capacity to commit mesenchymal stem cells to the osteoblastic lineage and to favor transdifferentiation of vascular smooth muscle cells into an osteoblast-like phenotype open a new area of interest in bone and vascular pathologies.

  10. A biomechanical comparison of 3.5 locking compression plate fixation to 3.5 limited contact dynamic compression plate fixation in a canine cadaveric distal humeral metaphyseal gap model.

    Science.gov (United States)

    Filipowicz, D; Lanz, O; McLaughlin, R; Elder, S; Werre, S

    2009-01-01

    3.5 locking compression plate (LCP) fixation was compared to 3.5 limited contact dynamic compression plate (LC-DCP) fixation in a canine cadaveric, distal humeral metaphyseal gap model. Thirty paired humeri from adult, large breed dogs were separated into equal groups based on testing: static compression, cyclic compression, and cyclic torsion. Humeral constructs stabilised with LCP were significantly stiffer than those plated with LC-DCP when loaded in static axial compression (P = 0.0004). When cyclically loaded in axial compression, the LCP constructs were significantly less stiff than the LC-DCP constructs (P = 0.0029). Constructs plated with LCP were significantly less resistant to torsion over 500 cycles than those plated with LC-DCP (Plocking plates may be attributed to the stability afforded by the plate-screw interface of locking plates. The LCP constructs demonstrated less stiffness in dynamic testing in this model, likely due to plate-bone offset secondary to non-anatomic contouring and occasional incomplete seating of the locking screws when using the torque-limiting screw driver. Resolution of these aspects of LCP application may help improve the stiffness of fixation in fractures modeled by the experimental set-up of this investigation.

  11. Electrically induced mechanical precompression of ferroelectric plates

    Science.gov (United States)

    Chen, P.J.

    1987-03-02

    A method of electrically inducing mechanical precompression of ferroelectric plate covered with electrodes utilizes the change in strains of the plate as functions of applied electric field. A first field polarizes and laterally shrinks the entire plate. An outer portion of the electrodes are removed, and an opposite field partially depolarizes and expands the central portion of the plate against the shrunk outer portion. 2 figs.

  12. 3D-Printing Plates without "Support"

    OpenAIRE

    Yasusi Kanada

    2015-01-01

    When printing a plate (or dish) by an FDM 3D printer, the process normally requires support material, which causes several problems. This paper proposes a method for forming thin plates without using wasteful support material. This method requires several extraordinary parameter values when slicing plates. The experiments show that the plates can, for the most part, be successfully formed using a conventional slicer and a 3D printer; however, seams between layers spoil th...

  13. Modeling the hydrodynamics of Phloem sieve plates

    DEFF Research Database (Denmark)

    Jensen, Kaare Hartvig; Mullendore, Daniel Leroy; Holbrook, Noel Michele

    2012-01-01

    Sieve plates have an enormous impact on the efficiency of the phloem vascular system of plants, responsible for the distribution of photosynthetic products. These thin plates, which separate neighboring phloem cells, are perforated by a large number of tiny sieve pores and are believed to play...... are investigated. We find that the sieve plate resistance is correlated to the cell lumen resistance, and that the sieve plate and the lumen contribute almost equally to the total hydraulic resistance of the phloem translocation pathway....

  14. Tetanus after allogeneic bone-marrow transplantation

    International Nuclear Information System (INIS)

    Kendra, J.R.; Halil, O.; Barrett, A.J.; Selwyn, S.

    1982-01-01

    A brief report is presented of a case of tetanus after allogeneic bone-marrow transplantation complicated by radiation-induced pneumonitis. A 30-year-old army sergeant received a bone-marrow transplant from his brother for the treatment of a granulocytic sarcoma after local radiotherapy to the tumour. Six years earlier he had sustained an open, compound fracture of the left tibia and fibula while on army exercise. At the time a pin and plate had been inserted and booster anti-tetanus administered. Bone-marrow transplantation was performed after total body irradiation. Cyclosporin A was given against graft-versus-host disease. Fifty four days after transplantation tetanus was diagnosed and death followed 14 days later. Necropsy disclosed radiation-induced pneumonitis, but no organisms were cultured from the lungs or the old fracture site. It is suggested that spores were incorporated into the wound site before surgery and that oxygenation around the plate became compromised after transplantation, permitting germination of dormant spores, immunosuppression allowing development of the disease. (U.K.)

  15. Tetanus after allogeneic bone-marrow transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Kendra, J.R.; Halil, O.; Barrett, A.J.; Selwyn, S. (Westminster Medical School, London (UK))

    1982-11-13

    A brief report is presented of a case of tetanus after allogeneic bone-marrow transplantation complicated by radiation-induced pneumonitis. A 30-year-old army sergeant received a bone-marrow transplant from his brother for the treatment of a granulocytic sarcoma after local radiotherapy to the tumour. Six years earlier he had sustained an open, compound fracture of the left tibia and fibula while on army exercise. At the time a pin and plate had been inserted and booster anti-tetanus administered. Bone-marrow transplantation was performed after total body irradiation. Cyclosporin A was given against graft-versus-host disease. Fifty four days after transplantation tetanus was diagnosed and death followed 14 days later. Necropsy disclosed radiation-induced pneumonitis, but no organisms were cultured from the lungs or the old fracture site. It is suggested that spores were incorporated into the wound site before surgery and that oxygenation around the plate became compromised after transplantation, permitting germination of dormant spores, immunosuppression allowing development of the disease.

  16. ITRF2014 plate motion model

    Science.gov (United States)

    Altamimi, Zuheir; Métivier, Laurent; Rebischung, Paul; Rouby, Hélène; Collilieux, Xavier

    2017-06-01

    For various geodetic and geophysical applications, users need to have access to a plate motion model (PMM) that is consistent with the ITRF2014 frame. This paper describes the approach used for determining a PMM from the horizontal velocities of a subset of the ITRF2014 sites away from plate boundaries, Glacial Isostatic Adjustment regions and other deforming zones. In theory it would be necessary to include in the inversion model a translational motion vector (called in this paper origin rate bias, ORB) that would represent the relative motion between the ITRF2014 origin (long-term averaged centre of mass of the Earth as sensed by SLR) and the centre of tectonic plate motion. We show that in practice, the magnitude of the estimated ORB is strongly dependent on the selection of ITRF2014 sites used for the PMM adjustment. Its Z-component can in particular range between 0 and more than 1 mm yr-1 depending on the station network used, preventing any geophysical interpretation of the estimated value. Relying on rigorous statistical criteria, the site selection finally adopted for the ITRF2014-PMM adjustment leads to a relatively small ORB (0.30 ± 0.18 mm yr-1 in the Z-component), which is statistically insignificant at the 2-sigma level, but also according to an F-ratio test. Therefore we opted for an ITRF2014-PMM without estimating the ORB, which in turn accommodates geodetic applications that require access to the ITRF2014 frame through pure plate rotation poles.

  17. Aseptic Laboratory Techniques: Plating Methods

    OpenAIRE

    Sanders, Erin R.

    2012-01-01

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five method...

  18. PRETREATING URANIUM FOR METAL PLATING

    Science.gov (United States)

    Wehrmann, R.F.

    1961-05-01

    A process is given for anodically treating the surface of uranium articles, prior to metal plating. The metal is electrolyzed in an aqueous solution of about 10% polycarboxylic acid, preferably oxalic acid, from 1 to 5% by weight of glycerine and from 1 to 5% by weight of hydrochloric acid at from 20 to 75 deg C for from 30 seconds to 15 minutes. A current density of from 60 to 100 amperes per square foot is used.

  19. Modified tubularized incised plate urethroplasty

    Directory of Open Access Journals (Sweden)

    Shivaji Mane

    2013-01-01

    Full Text Available Aim: To share our experience of doing tubularized incised plate urethroplasty with modifications. Materials and Methods: This is a single surgeon personal series from 2004 to 2009. One hundred patients of distal hypospadias were subjected for Snodgrass urethroplasty with preputioplasty. The age range was 1 to 5 year with mean age of 2.7 years. Selection criteria were good urethral plate, without chordee and torsion needing complete degloving. Main technical modification from original Snodgrass procedure was spongioplasty, preputioplasty, and dorsal slit when inability to retract prepuce during surgery. Results: Average follow-up period is 23 months. Seven (7% patients developed fistula and one patient had complete preputial dehiscence. Phimosis developed in three (3% patients and required circumcision. Dorsal slit was required in seven patients. One patient developed meatal stenosis in postoperative period. All other patients are passing single urinary stream and have cosmesis that is acceptable. Conclusions: Modified tubularized incised plate urethroplasty with preputioplasty effectively gives cosmetically normal looking penis with low complications.

  20. Volcano spacing and plate rigidity

    Science.gov (United States)

    ten Brink, Uri S.

    1991-01-01

    In-plane stresses, which accompany the flexural deformation of the lithosphere under the load of adjacent volcanoes, may govern the spacing of volcanoes in hotspot provinces. Specifically, compressive stresses in the vicinity of a volcano prevent new upwelling in this area, forcing a new volcano to develop at a minimum distance that is equal to the distance in which the radial stresses change from compressional to tensile (the inflection point). If a volcano is modeled as a point load on a thin elastic plate, then the distance to the inflection point is proportional to the thickness of the plate to the power of 3/4. Compilation of volcano spacing in seven volcanic groups in East Africa and seven volcanic groups of oceanic hotspots shows significant correlation with the elastic thickness of the plate and matches the calculated distance to the inflection point. In contrast, volcano spacing in island arcs and over subduction zones is fairly uniform and is much larger than predicted by the distance to the inflection point, reflecting differences in the geometry of the source and the upwelling areas.

  1. Short- and medium-term results of the thrust plate prosthesis in patients with polyarthritis.

    Science.gov (United States)

    Fink, B; Siegmüller, C; Schneider, T; Conrad, S; Schmielau, G; Rüther, W

    2000-01-01

    The thrust plate prosthesis is an implant with metaphyseal fixation to the proximal femur, which leaves the diaphyseal bone untouched. Therefore, this implant is preferred in younger patients. It is dependent on good bone quality in the proximal femur. Because the bone quality is reduced in patients with polyarthritis, this kind of endoprosthesis may have a higher failure rate than conventional stemmed endoprostheses in these patients. Therefore, in patients with polyarthritis, even short- and medium-term results of the thrust plate prosthesis should be analyzed. In all, 47 thrust plate prostheses were implanted in 42 patients with polyarthritis (29 with rheumatoid arthritis, 6 with juvenile chronic arthritis, and 7 with spondylarthritis) and followed prospectively. The average age at operation was 40.8+/-10.7 years. Each patient was clinically and radiologically examined preoperatively, 3 and 6 months after the operation, and at the end of each postoperative year. The mean follow-up was 26.1+/-10.7 months. The clinical findings were evaluated using the Harris hip score. Radiologically, 8 different zones of the thrust plate prosthesis were analyzed for radiolucencies. During the 1st year, the Harris hip score rose continuously from the preoperative average of 42.4+/-6.5 points to 78.8+/-10.3 points 3 months postoperatively, 82.3+/-9.8 points 6 months postoperatively, and 86.8+/-10.1 points 1 year after the operation. The subsequent examinations showed Harris hip score remained at the same level. Five patients (5 joints, 10.6%) had to undergo a revision of the thrust plate prosthesis due to aseptic loosening in 3 and septic loosening in 2. Six prostheses (12.6%) showed radiolucencies, mostly below the thrust plate in zones 1 and 2. Two of them were certainly radiologically loose, which raised the failure rate to 7 of 47 (14.8%). The thrust plate prosthesis improves function and alleviates pain in patients with polyarthritis to a satisfactory degree. Concerning the

  2. Low-profile plate fixation in arthrodesis of the first metacarpophalangeal joint

    DEFF Research Database (Denmark)

    Rasmussen, Claudia; Roos, S; Boeckstyns, M

    2011-01-01

    case a tenolysis. Follow-up time was 13-92 months (mean 52). There was no correlation between patient satisfaction and position of fusion. We conclude that this technique gives a high rate of union, a short period of immobilization and rehabilitation, and a reliable position at the site of fusion.......Fifty-one consecutive arthrodeses (46 patients) of the first metacarpophalangeal joint were retrospectively reviewed, after fixation with a Leibinger low-profile titanium plate, using a cup-and-cone technique. Primary bone union was achieved in 98%. Three cases required removal of the plate and one...

  3. Comparative stability of perpendicular versus parallel double-locking plating systems in osteoporotic comminuted distal humerus fractures.

    Science.gov (United States)

    Stoffel, Karl; Cunneen, Sam; Morgan, Robert; Nicholls, Rochelle; Stachowiak, Gwidon

    2008-06-01

    In distal humerus fractures, the restoration of stability is important to allow early mobilization and hence more favorable functional outcomes. In this article, we compare the biomechanical stability of perpendicular and parallel locking plating systems for the internal fixation of AO Type C2 distal humerus fractures in osteoporotic bone. Fractures were simulated in paired cadaveric bones and fixed using either the perpendicular 3.5 mm LCP distal humerus plating system (Synthes; Sydney, Australia) or the parallel Mayo Clinic Congruent elbow plate system (Acumed; Hillsboro, OR), using locking screws in both systems. Both systems were then tested for their stiffness (in compression and internal/external rotation), plastic deformation, and failure in torsion. Comparatively, the parallel locking plate system provided a significantly higher stability in compression (p = 0.005) and external rotation (p = 0.006), and a greater ability (p = 0.005) to resist axial plastic deformation. Stability for both constructs appeared to be dependent on bone quality, however the stability of the perpendicular system was generally more sensitive to bone mineral density, indicating a possible need for additional independent interfragmentary screws. A disadvantage of the parallel locking plate system was wear debris produced by its tapping system. In summary, the biomechanical findings of this study suggest that both locking plate systems allow early mobilization of the elbow in patients with osteoporotic bone following fixation of a comminuted distal humerus fracture. However, the parallel locking system showed improved stability compared with the perpendicular locking system, and therefore may be more indicated. (c) 2008 Orthopaedic Research Society.

  4. Macrophages and bone inflammation

    Directory of Open Access Journals (Sweden)

    Qiaoli Gu

    2017-07-01

    Full Text Available Bone metabolism is tightly regulated by the immune system. Accelerated bone destruction is observed in many bone diseases, such as rheumatoid arthritis, fracture, and particle-induced osteolysis. These pathological conditions are associated with inflammatory responses, suggesting the contribution of inflammation to bone destruction. Macrophages are heterogeneous immune cells and are polarized into the proinflammatory M1 and antiinflammatory M2 phenotypes in different microenvironments. The cytokines produced by macrophages depend on the macrophage activation and polarization. Macrophages and macrophage-derived cytokines are important to bone loss in inflammatory bone disease. Recent studies have shown that macrophages can be detected in bone tissue and interact with bone cells. The interplay between macrophages and bone cells is critical to bone formation and repair. In this article, we focus on the role of macrophages in inflammatory bone diseases, as well as discuss the latest studies about macrophages and bone formation, which will provide new insights into the therapeutic strategy for bone disease.

  5. Permeability studies of artificial and natural cancellous bone structures.

    Science.gov (United States)

    Syahrom, Ardiyansyah; Abdul Kadir, Mohammed Rafiq; Abdullah, Jaafar; Öchsner, Andreas

    2013-06-01

    In the development of artificial cancellous bones, two major factors need to be considered: the integrity of the overall structure and its permeability. Whilst there have been many studies analysing the mechanical properties of artificial and natural cancellous bones, permeability studies, especially those using numerical simulation, are scarce. In this study, idealised cancellous bones were simulated from the morphological indices of natural cancellous bone. Three different orientations were also simulated to compare the anisotropic nature of the structure. Computational fluid dynamics methods were used to analyse fluid flow through the cancellous structures. A constant mass flow rate was used to determine the intrinsic permeability of the virtual specimens. The results showed similar permeability of the prismatic plate-and-rod model to the natural cancellous bone. The tetrakaidecahedral rod model had the highest permeability under simulated blood flow conditions, but the plate counterpart had the lowest. Analyses on the anisotropy of the virtual specimens showed the highest permeability for the horizontal orientation. Linear relationships were found between permeability and the two physical properties, porosity and bone surface area. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  6. Opposing Extremes of Zygomatic Bone Morphology: Australopithecus Boisei versus Homo Neanderthalensis.

    Science.gov (United States)

    Rak, Yoel; Marom, Assaf

    2017-01-01

    The lateral margin of the zygomatic bone of Australopithecus boisei flares both anteriorly and laterally. As a result, the bone loses the suspensory bracing of the facial frame and is transformed into a visor-like structure that supports itself and gains its rigidity from its shape. The coronally oriented bony plates and the outline of the facial mask help the A. boisei face resist the effect of the visor-like structure, which tends to pull the bone plates of the face away from the midline. On the other hand, the nearly sagittal orientation of the zygomatic bone in Homo neanderthalensis helps the face resist torque and bending forces, which themselves stem from the positioning of the bite point on the anterior teeth. Although the zygomatic bones of these two taxa are highly specialized, they differ fundamentally from each other. Anat Rec, 300:152-159, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  7. Parametric study of patient-specific femoral locking plates based on a combined musculoskeletal multibody dynamics and finite element modeling.

    Science.gov (United States)

    Fan, Xunjian; Chen, Zhenxian; Jin, Zhongmin; Zhang, Qida; Zhang, Xuan; Peng, Yinghu

    2018-02-01

    A combined musculoskeletal multibody dynamics and finite element modeling was performed to investigate the effects of design parameters on the fracture-healing efficiency and the mechanical property of a patient-specific anatomically adjusted femoral locking plate. Specifically, the screw type, the thickness and material of the locking plate, the gap between two femoral fragments (fracture gap) and the distance between bone and plate (interface gap) were evaluated during a human walking. We found that the patient-specific locking plate possessed greater mechanical strength and more efficient fracture healing than the corresponding traditional plate. An optimal patient-specific femoral locking plate would consist of bicortical locking screws, Ti-6Al-4V material and 4.75-mm plate thickness with a fracture gap of 2 mm and an interface gap of 1 mm. The developed patient-specific femoral locking plate based on the patient-specific musculoskeletal mechanical environment was more beneficial to fracture rehabilitation and healing. The patient-specific design method provides an effective research platform for designing and optimizing the patient-specific femoral locking plate under realistic in vivo walking conditions, which can be extended to the design of other implants as well as to other physiological loading conditions related to various daily activities.

  8. CNEA developments in U-Mo-ZrY-4 mini plates and plates fabrication process

    International Nuclear Information System (INIS)

    López, M.; Picchetti, B.; Gonzalez, A.; Taboada, H.

    2013-01-01

    The Uranium Molybdenum alloy was the material chosen to develop the fabrication of high density nuclear fuel, due to its excellent behaviour under irradiation –a consequence of the metastable bcc crystalline structure-. At present, the study is focused on the application of this alloy to monolithic fuel plate development, which fuel core is a thin U-Mo layer. The Zircalloy-4 (Zry-4) alloy used as cladding material is extensively known in the nuclear industry due to its low neutron capture section efficiency and excellent mechanical and corrosion resistance properties. Miniplates fabrication process involves a welded compact made of two Zry-4 covers and a frame surrounding a monolithic U-Mo core, which is co rolled under high temperature. Molybdenum contains of 7% to 10% (mass) in U Mo alloys guarantees the presence of meta-stable bcc gamma phase and, at the same time, does not penalize the neutron economy due to Mo98 presence. In the case of U Mo monolithic miniplates relevant parameters of fabrication, considering the behaviour of the U-Mo alloys reported in many work and in order to optimize the o-rolling process, have been revised: co-rolling temperature, compressive stress and presence of gap. Under this experimental conditions can be studied the the interdiffusion layer, the binding between materials and the Dog Bone. The experimental results shows that 650ºC is an optimal co-rolling temperature; at higher temperatures not only a bigger interdiffusion layer is observed –this phenomenon can lead to a region enriched in Molybdenum- but also a bigger Dog Bone is obtained. Working at higher compressive stress has the same effect in relation to the interdiffusion layer. In addition, the absence of gases in the core is essential for the correct binding of the materials. Concerning the monolithic U-Mo plates fabrication, involved in the ALT FUTURE experiment a new workshop has been conditioned. The aim is to use all the valuable information collected during

  9. [Biomechanic study on length of plate in treatment of tibial shaft fracture].

    Science.gov (United States)

    Hu, Xinji; Yang, Shuhua; Xiao, Deming; Lin, Bowen; Wang, Hua; Xu, Zhongshi; Zhao, Weidong; Zhang, Meichao

    2008-11-01

    To research the biomechanical effect of different length bone plates on treatment of tibial shaft fracture. Forty-five tibia specimens from fresh adult corpse (20-40 years old) were donated (30-38 cm in length, 34 cm on average) and were divided into 3 groups randomly (n = 15). Under the following three conditions, the experiment was made separately. Compression stress-strain indexes of whole tibia were determined under the reverse, three spots curving and compression. The vertical elastic strain was 0-1 000 N, the reverse angle was 0-3 degrees, and three bending stress was 0-400 N. Then the center-section squint non-damage bone fracture model was made, fracture was fixed by 6, 10, 14 stainless steel AO LC-DCP, respectively. The compression stress-strain indexes were determined under reverse angle, three spots curving and compression, statistical analysis was done. The vertical direction strain value of 6, 10 and 14 hole steel plate under vertical compressions, was 0.449 +/- 0.241, 0.093 +/- 0.003, 0.139 +/- 0.005, respectively; showing significant difference between 10 and 14 hole steel plates and 6 steel plate (P 0.05). The lateral strain value of 6, 10 and 14 hole steel plate was 0.120 0 +/- 0.000 4, 0.127 5 +/- 0.010 0, 0.237 0 +/- 0.000 6 respectively, indicating a significant difference between stell plates of 6 and 10 hole and 14 hole steel plate (P 0.05). The torque of 6, 10 and 14 hole steel plate was (5.066 +/- 2.715) x 10(-3), (5.671 +/- 2.527) x 10(-3) and (4.570 +/- 2.228) x 10(-3) Nm, respectively and three spot curving vertical direction strain value was 0.049 +/- 0.009, 0.124 +/- 0.017, 0.062 +/- 0.009, respectively. There were significant differences between various steel plates (P < 0.01). For the fixation of tibial oblique fracture, 14 hole steel plate's stabilities of anti-vertical compression, anti-reverse and anti-curving are better than those of 6 hole steel plate under the condition of the same material quality, thickness, width and screw

  10. Bone mineral density test

    Science.gov (United States)

    BMD test; Bone density test; Bone densitometry; DEXA scan; DXA; Dual-energy x-ray absorptiometry; p-DEXA; Osteoporosis - BMD ... need to undress. This scan is the best test to predict your risk of fractures, especially of ...

  11. Temporal bone imaging

    International Nuclear Information System (INIS)

    Shaffer, K.A.

    1987-01-01

    Although pluridirectional tomography had been the standard method to evaluate the temporal bone, computed tomography has replaced it for nearly all applications. Magnetic resonance imaging can demonstrate nonosseous temporal bone structures as well

  12. Bone Marrow Diseases

    Science.gov (United States)

    ... that help with blood clotting. With bone marrow disease, there are problems with the stem cells or ... marrow makes too many white blood cells Other diseases, such as lymphoma, can spread into the bone ...

  13. Bone substitute biomaterials

    CERN Document Server

    Mallick, K

    2014-01-01

    Bone substitute biomaterials are fundamental to the biomedical sector, and have recently benefitted from extensive research and technological advances aimed at minimizing failure rates and reducing the need for further surgery. This book reviews these developments, with a particular focus on the desirable properties for bone substitute materials and their potential to encourage bone repair and regeneration. Part I covers the principles of bone substitute biomaterials for medical applications. One chapter reviews the quantification of bone mechanics at the whole-bone, micro-scale, and non-scale levels, while others discuss biomineralization, osteoductivization, materials to fill bone defects, and bioresorbable materials. Part II focuses on biomaterials as scaffolds and implants, including multi-functional scaffolds, bioceramics, and titanium-based foams. Finally, Part III reviews further materials with the potential to encourage bone repair and regeneration, including cartilage grafts, chitosan, inorganic poly...

  14. What causes bone loss?

    Science.gov (United States)

    ... Paula FJA, Black DM, Rosen CJ. Osteoporosis and bone biology. In: Melmed S, Polonsky KS, Larsen PR, Kronenberg HM, eds. Williams Textbook of Endocrinology . 13th ed. Philadelphia, PA: ... HM. Bone development and remodeling. In: Jameson JL, De Groot ...

  15. Comparative study of bridge plate associated to the intramedullary pin and the dynamic compression plate on the experimental osteotomy fixation of femoral in rabbits (Oryctolagus cuniculus). Clinical, radiographic, histological and scintigraphy analyses

    International Nuclear Information System (INIS)

    Borges, Natalie Ferreira

    2011-01-01

    The objectives were to benchmark and monitor the fracture healing of femoral osteotomy in rabbits after fixation with dynamic compression plate and bridge plate associated with intramedullary pin. Were used 14 New Zealand rabbits, four months old with mean weight of 3.5 pounds, from the Experimental Farm Professor Helio Barbosa of the Veterinary School of Minas Gerais Federal Univ. (UFMG). The animals were randomly divided into two groups (I and II). All rabbits underwent osteotomy across the middle third of right femur. In the group I was made to fix the osteotomy with the bridge plate (BP) associated with intramedullary pin, introduced the technique of minimal invasion. In group II, we used dynamic compression plate (DCP) via the conventional approach. Both groups were evaluated clinical, radiographic, histologic and scintigraphic findings. Clinical assessments were performed weekly until the 12 th postoperative week and radiographic examinations were performed before, immediately after, at 15, 30, 45, 60 and 90 days. The bone scintigraphy were performed before and at 20, 50 and 90 days after surgery to monitor the bone metabolism qualitatively and quantitatively. Observed perfusion and bone healing process. After 90 days of study, there was histopathologic evaluation of the osteotomized area and the insertion of screws. In the region of the osteotomy was observed predominance of trabecular bone in group I and group II, the predominance of bone osteons, compatible with the original bone. On insertion of the screws did not differ between groups and there was cortical discontinuity, little necrosis and local hemorrhage. The two types of fixation have led to consolidation within the scheduled period, maturing in early fixation with DCP fixation compared with BP. Scintigraphy demonstrated by the indices of activity and image characteristics, the process of bone healing was significantly greater in animals undergoing early fixation with DCP. (author)

  16. Dual-energy X-ray absorptiometry and force-plate analysis of gait in dogs with healed femora after leg-lengthening plate fixation

    International Nuclear Information System (INIS)

    Muir, P.; Markel, M.D.; Bogdanske, J.J.; Johnson, K.A.

    1995-01-01

    Dual-energy x-ray absorptiometry was used to measure bone mineral density of four regions in healed femora of nine dogs after fracture fixation with a leg-lengthening plate. Six to 85 months (mean, 46 months) after surgery, the bone mineral density of healed femora was not significantly different from the contralateral uninjured femora (P > .05; power = 0.8 at delta = 15%). Radiolucencies around the proximal screws, apparently associated with screw loosening, were seen on radiographic views of the healed femora of three dogs. In one of these dogs, one screw in the proximal metaphysis had broken. Force-plate analysis of gait was also performed on dogs at the time of bone mineral density measurement. Peak vertical force was decreased in the pelvic limb with the healed fracture compared with the contralateral unoperated limb (P < 0.05). Clinically apparent lameness in three dogs did not appear to be associated with altered bone mineral density and may have been caused by hip osteoarthritis, a nondisplaced hairline diaphyseal fracture, and screw loosening in conjunction with extensive post-traumatic soft tissue injury

  17. Load-sharing through elastic micro-motion accelerates bone formation and interbody fusion.

    Science.gov (United States)

    Ledet, Eric H; Sanders, Glenn P; DiRisio, Darryl J; Glennon, Joseph C

    2018-02-13

    Achieving a successful spinal fusion requires the proper biological and biomechanical environment. Optimizing load-sharing in the interbody space can enhance bone formation. For anterior cervical discectomy and fusion (ACDF), loading and motion are largely dictated by the stiffness of the plate, which can facilitate a balance between stability and load-sharing. The advantages of load-sharing may be substantial for patients with comorbidities and in multilevel procedures where pseudarthrosis rates are significant. We aimed to evaluate the efficacy of a novel elastically deformable, continuously load-sharing anterior cervical spinal plate for promotion of bone formation and interbody fusion relative to a translationally dynamic plate. An in vivo animal model was used to evaluate the effects of an elastically deformable spinal plate on bone formation and spine fusion. Fourteen goats underwent an ACDF and received either a translationally dynamic or elastically deformable plate. Animals were followed up until 18 weeks and were evaluated by plain x-ray, computed tomography scan, and undecalcified histology to evaluate the rate and quality of bone formation and interbody fusion. Animals treated with the elastically deformable plate demonstrated statistically significantly superior early bone formation relative to the translationally dynamic plate. Trends in the data from 8 to 18 weeks postoperatively suggest that the elastically deformable implant enhanced bony bridging and fusion, but these enhancements were not statistically significant. Load-sharing through elastic micro-motion accelerates bone formation in the challenging goat ACDF model. The elastically deformable implant used in this study may promote early bony bridging and increased rates of fusion, but future studies will be necessary to comprehensively characterize the advantages of load-sharing through micro-motion. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  18. Gracile bone dysplasias

    Energy Technology Data Exchange (ETDEWEB)

    Kozlowski, Kazimierz [Department of Medical Imaging, The Children' s Hospital at Westmead, Locked Bag 4001, Westmead 2145, NSW (Australia); Masel, John [Department of Radiology, Royal Children' s Hospital, Brisbane (Australia); Sillence, David O. [Department of Paediatrics and Child Health, The University of Sydney (Australia); Arbuckle, Susan [Department of Anatomical Pathology, The Children' s Hospital at Westmead, NSW (Australia); Juttnerova, Vera [Oddeleni Lekarske Genetiky, Hradec Kralove (Czech Republic)

    2002-09-01

    Gracile bone dysplasias constitute a group of disorders characterised by extremely slender bones with or without fractures. We report four newborns, two of whom showed multiple fractures. Two babies had osteocraniostenosis and one had features of oligohydramnios sequence. The diagnosis in the fourth newborn, which showed thin long bones and clavicles and extremely thin, poorly ossified ribs, is uncertain. Exact diagnosis of a gracile bone dysplasia is important for genetic counselling and medico-legal reasons. (orig.)

  19. Peridinialean dinoflagellate plate patterns, labels and homologies

    Science.gov (United States)

    Edwards, L.E.

    1990-01-01

    Tabulation patterns for peridinialean dinoflagellate thecae and cysts have been traditionally expressed using a plate labelling system described by C.A. Kofoid in the early 1900's. This system can obscure dinoflagellate plate homologies and has not always been strictly applied. The plate-labelling system presented here introduces new series labels but incorporates key features and ideas from the more recently proposed systems of G.L. Eaton and F.J.R. Taylor, as modified by W.R. Evitt. Plate-series recognition begins with the cingulum (C-series) and proceeds from the cingulum toward the apex for the three series of the epitheca/epicyst and proceeds from the cingulum toward the antapex for the two series of the hypotheca/hypocyst. The epithecal/epicystal model consists of eight plates that touch the anterior margin of the cingulum (E-series: plates E1-E7, ES), seven plates toward the apex that touch the E-series plates (M-series: R, M1-M6), and up to seven plates near the apex that do not touch E-series plates (D-series: Dp-Dv). The hypothecal/hypocystal model consists of eight plates that touch the posterior margin of the cingulum (H-series: H1-H6,HR,HS) and three plates toward the antapex (T1-T3). Epithecal/epicystal tabulation patterns come in both 8- and 7- models, corresponding to eight and seven plates, respectively, in the E-series. Hypothecal/hypocystal tabulation patterns also come in both 8- and 7-models, corresponding to eight and seven plates, respectively, in the H-series. By convention, the 7-model epitheca/epicyst has no plates E1 and M1; the 7-model hypotheca/hypocyst has no plate H6. Within an 8-model or 7-model, the system emphasizes plates that are presumed to be homologous by giving them identical labels. I introduce the adjectives "monothigmate", "dithigmate," and "trithigmate" to designate plates touching one, two, and three plates, respectively, of the adjacent series. The term "thigmation" applies to the analysis of plate contacts between

  20. Fracture healing in osteoporotic bone.

    Science.gov (United States)

    Cheung, Wing Hoi; Miclau, Theodore; Chow, Simon Kwoon-Ho; Yang, Frank F; Alt, Volker

    2016-06-01

    As the world population rises, osteoporotic fracture is an emerging global threat to the well-being of elderly patients. The process of fracture healing by intramembranous ossification or/and endochondral ossification involve many well-orchestrated events including the signaling, recruitment and differentiation of mesenchymal stem cells (MSCs) during the early phase; formation of a hard callus and extracellular matrix, angiogenesis and revascularization during the mid-phase; and finally callus remodeling at the late phase of fracture healing. Through clinical and animal research, many of these factors are shown to be impaired in osteoporotic bone. Animal studies related to post-menopausal estrogen deficient osteoporosis (type I) have shown healing to be prolonged with decreased levels of MSCs and decreased levels of angiogenesis. Moreover, the expression of estrogen receptor (ER) was shown to be delayed in ovariectomy-induced osteoporotic fracture. This might be related to the observed difference in mechanical sensitivity between normal and osteoporotic bones, which requires further experiments to elucidate. In mice fracture models related to senile osteoporosis (type II), it was observed that chondrocyte and osteoblast differentiation were impaired; and that transplantation of juvenile bone marrow would result in enhanced callus formation. Other factors related to angiogenesis and vasculogenesis have also been noted to be impaired in aged models, affecting the degradation of cartilaginous matrixes and vascular invasion; the result is changes in matrix composition and growth factors concentrations that ultimately impairs healing during age-related osteoporosis. Most osteoporotic related fractures occur at metaphyseal sites clinically, and reports have indicated that differences exist between diaphyseal and metaphyseal fractures. An animal model that satisfies three main criteria (metaphyseal region, plate fixation, osteoporosis) is suggested for future research for

  1. [Artificial bone substitutes].

    Science.gov (United States)

    Koníček, Petr

    Bone tissue substitutes are divided into basic classification with its pros and cons described. Arteficial bone grafts are especially pointed out in article, publishing our own experience with two specific synthetic preps. Finally there is a blink in the near future of bone tissue augmentation.

  2. (unicameral) bone cysts

    African Journals Online (AJOL)

    When encountering a radiologically benign lucent bone lesion in a child, a simple bone cyst is a reasonable diagnostic consideration. Simple or unicameral bone cysts are expansile, serous-fluid-containing defects, that are not true neoplasms. Peak age ranges between 3 and 14 years in. 80% of cases. The incidence is ...

  3. A biomechanical comparison of proximal femoral nails and locking proximal anatomic femoral plates in femoral fracture fixation

    Science.gov (United States)

    Ozkan, Korhan; Türkmen, İsmail; Sahin, Adem; Yildiz, Yavuz; Erturk, Selim; Soylemez, Mehmet Salih

    2015-01-01

    Background: The incidence of fractures in the trochanteric area has risen with the increasing numbers of elderly people with osteoporosis. Although dynamic hip screw fixation is the gold standard for the treatment of stable intertrochanteric femur fractures, treatment of unstable intertrochanteric femur fractures still remains controversial. Intramedullary devices such as Gamma nail or proximal femoral nail and proximal anatomic femur plates are in use for the treatment of intertrochanteric femur fractures. There are still many investigations to find the optimal implant to treat these fractures with minimum complications. For this reason, we aimed to perform a biomechanical comparison of the proximal femoral nail and the locking proximal anatomic femoral plate in the treatment of unstable intertrochanteric fractures. Materials and Methods: Twenty synthetic, third generation human femur models, obtained for this purpose, were divided into two groups of 10 bones each. Femurs were provided as a standard representation of AO/Orthopedic Trauma Associationtype 31-A2 unstable fractures. Two types of implantations were inserted: the proximal femoral intramedullary nail in the first group and the locking anatomic femoral plate in the second group. Axial load was applied to the fracture models through the femoral head using a material testing machine, and the biomechanical properties of the implant types were compared. Result: Nail and plate models were locked distally at the same level. Axial steady load with a 5 mm/m velocity was applied through the mechanical axis of femur bone models. Axial loading in the proximal femoral intramedullary nail group was 1.78-fold greater compared to the plate group. All bones that had the plate applied were fractured in the portion containing the distal locking screw. Conclusion: The proximal femoral intramedullary nail provides more stability and allows for earlier weight bearing than the locking plate when used for the treatment of

  4. Selective laser melting-produced porous titanium scaffolds regenerate bone in critical size cortical bone defects.

    Science.gov (United States)

    Van der Stok, Johan; Van der Jagt, Olav P; Amin Yavari, Saber; De Haas, Mirthe F P; Waarsing, Jan H; Jahr, Holger; Van Lieshout, Esther M M; Patka, Peter; Verhaar, Jan A N; Zadpoor, Amir A; Weinans, Harrie

    2013-05-01

    Porous titanium scaffolds have good mechanical properties that make them an interesting bone substitute material for large bone defects. These scaffolds can be produced with selective laser melting, which has the advantage of tailoring the structure's architecture. Reducing the strut size reduces the stiffness of the structure and may have a positive effect on bone formation. Two scaffolds with struts of 120-µm (titanium-120) or 230-µm (titanium-230) were studied in a load-bearing critical femoral bone defect in rats. The defect was stabilized with an internal plate and treated with titanium-120, titanium-230, or left empty. In vivo micro-CT scans at 4, 8, and 12 weeks showed more bone in the defects treated with scaffolds. Finally, 18.4 ± 7.1 mm(3) (titanium-120, p = 0.015) and 18.7 ± 8.0 mm(3) (titanium-230, p = 0.012) of bone was formed in those defects, significantly more than in the empty defects (5.8 ± 5.1 mm(3) ). Bending tests on the excised femurs after 12 weeks showed that the fusion strength reached 62% (titanium-120) and 45% (titanium-230) of the intact contralateral femurs, but there was no significant difference between the two scaffolds. This study showed that in addition to adequate mechanical support, porous titanium scaffolds facilitate bone formation, which results in high mechanical integrity of the treated large bone defects. Copyright © 2012 Orthopaedic Research Society.

  5. Dense chromatin plates in metaphase chromosomes.

    Science.gov (United States)

    Gállego, Isaac; Castro-Hartmann, Pablo; Caravaca, Juan Manuel; Caño, Silvia; Daban, Joan-Ramon

    2009-04-01

    In a previous work we observed multilayered plate-like structures surrounding partially denatured HeLa chromosomes at metaphase ionic conditions. This unexpected finding has led us to carry out an extensive investigation of these structures. Our results show that plates can also be found in metaphase chromosomes from chicken lymphocytes. We have used atomic force microscopy (AFM) to image and investigate the mechanical properties of plates in aqueous solution. Plates are thin (approximately 6.5 nm each layer) but compact and resistant to penetration by the AFM tip: their Young's modulus is approximately 0.2 GPa and the stress required for surface penetration is approximately 0.03 GPa in the presence of Mg(2+) (5-20 mM). Low-ionic strength conditions produce emanation of chromatin fibers from the edges of uncrosslinked plates. These observations and AFM results obtained applying high forces indicate that the chromatin filament is tightly tethered inside the plates. Images of metal-shadowed plates and cryo-electron microscopy images of frozen-hydrated plates suggest that nucleosomes are tilted with respect to the plate surface to allow an interdigitation between the successive layers and a thickness reduction compatible with the observed plate height. The similarities between denatured plates from chicken chromosomes and aggregates of purified chromatin from chicken erythrocytes suggest that chromatin has intrinsic structural properties leading to plate formation. Scanning electron micrographs and images obtained with the 200-kV transmission microscope show that plates are the dominant component of compact chromatids. We propose that metaphase chromosomes are formed by many stacked plates perpendicular to the chromatid axis.

  6. Marked changes in iliac crest bone structure in postmenopausal osteoporotic patients without any signs of disturbed bone remodeling or balance.

    Science.gov (United States)

    Steiniche, T; Christiansen, P; Vesterby, A; Hasling, C; Ullerup, R; Mosekilde, L; Melsen, F

    1994-01-01

    Successful iliac crest bone biopsies were obtained from 63 women with postmenopausal vertebral crush fracture osteoporosis. Structural and static histomorphometric parameters were compared with 25 age-matched normal females, who had suffered an unexpected and sudden death. The control group for dynamic parameters comprised 13 younger normal females. Marked structural changes were observed in the osteoporotic patients in cortical as well as cancellous bone. Cortical width, trabecular volume, trabecular bone surface density and trabecular number were all reduced, whereas trabecular separation and star volume were increased. On the other hand trabecular thickness was normal in the patients. These structural changes in cancellous bone indicate that extensive perforations of trabecular plates have occurred or that whole trabecular elements have been removed. The remodeling cycles of cancellous bone surface and the frequency by which they were repeated (activation frequency) did not differ significantly between osteoporotic patients and normal younger women. The bone balance per remodeling cycle in osteoporotic patients and controls was not significantly different. No subset of individuals in the group of osteoporotic patients could be identified regarding extent of resorptive and formative surfaces, bone formation rate or activation frequency. In the present osteoporotic patients nothing in the ongoing remodeling process could explain the marked changes in bone structure. The pathophysiological changes leading to osteoporosis may therefore occur earlier in life, maybe long before the manifestation of the disease.

  7. Micro plate fission chamber development

    International Nuclear Information System (INIS)

    Wang Mei; Wen Zhongwei; Lin Jufang; Jiang Li; Liu Rong; Wang Dalun

    2014-01-01

    To conduct the measurement of neutron flux and the fission rate distribution at several position in assemblies, the micro plate fission chamber was designed and fabricated. Since the requirement of smaller volume and less structure material was taken into consideration, it is convinient, commercial and practical to use fission chamber to measure neutron flux in specific condition. In this paper, the structure of fission chamber and process of fabrication were introduced and performance test result was presented. The detection efficiency is 91.7%. (authors)

  8. Optimization of neutron imaging plate

    CERN Document Server

    Haga, Y K; Takahashi, K; Niimura, N

    2002-01-01

    Considering the elementary processes of neutron detection occurring in the neutron imaging plate (NIP) has optimized the performance of NIP. For these processes, the color center creation efficiencies (epsilon sub c sub c values) have been experimentally determined with NIPs which have different mole fraction of photostimulated (PSL) material (phi sub P sub S sub L values) and different thickness (t). The effectiveness of the optimization procedure has been demonstrated by the measurement of the neutron diffraction intensities from a hen egg-white lysozyme protein crystal.

  9. Cytology of Bone.

    Science.gov (United States)

    Barger, Anne M

    2017-01-01

    Cytology of bone is a useful diagnostic tool. Aspiration of lytic or proliferative lesions can assist with the diagnosis of inflammatory or neoplastic processes. Bacterial, fungal, and protozoal organisms can result in significant osteomyelitis, and these organisms can be identified on cytology. Neoplasms of bone including primary bone tumors such as osteosarcoma, chondrosarcoma, fibrosarcoma, synovial cell sarcoma, and histiocytic sarcoma and tumors of bone marrow including plasma cell neoplasia and lymphoma and metastatic neoplasia can result in significant bone lysis or proliferation and can be diagnosed effectively with cytology. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Failure of volar locking plate fixation of an extraarticular distal radius fracture: A case report

    Directory of Open Access Journals (Sweden)

    Ozer Kagan

    2010-11-01

    Full Text Available Abstract Background Volar locking plates provide significant structural stability to the distal radius. Failure of a volar locked plating is a rarely reported complication in the literature. Case Presentation A 40 year-old, obese female patient who presented with a displaced extraarticular distal radius fracture, underwent open reduction and internal fixation of the fracture using a volar locking plate. Radiographs taken at 10 weeks postoperatively showed failure of fixation with breakage of the four distal locking screws. A hardware removal was performed at 6 months, and the patient was then lost to follow-up. She presented again at 18 months after the first surgery, with significant pain, and radiographic signs of a radial collapse and a fracture-nonunion. A total wrist fusion was performed as the method of choice at that point in time. Conclusion Volar locked plating represents the new "gold standard" of distal radius fracture fixation. However, despite the stability provided by locking plates, hardware failure may occur and lead to a cascade of complications which will ultimately require a wrist fusion, as outlined in this case report. Additional structural support by bone grafting may be needed in selected cases of volar locked plating, particularly in patients with a high risk of developing a fracture-nonunion.

  11. Staple versus locking compression plate fixation after lateral closing wedge high tibial osteotomy.

    Science.gov (United States)

    Agarwala, S; Shah, S B

    2008-12-01

    To compare the results of staple versus locking compression plate fixation after closing wedge high tibial osteotomy. A group of 23 patients (24 knees) who underwent box high tibial osteotomy and staple fixation was compared with another group of 19 patients (22 knees) who underwent a similar procedure but with locking compression plate fixation. Both groups were followed up for 3 years. The range of movement, Hospital for Special Surgery (HSS) Knee Score, time to full weight bearing, incidence of delayed union, femorotibial angle, and stage of osteoarthritis were compared. At 6 months after the operation, the median HSS score and the proportion of patients with excellent or good scores were significantly higher in the locking compression plate than the staple fixation group (76 vs 62, p=0.003; 75% vs 42%, p=0.0354), but not at one and 3 years. The range of movement was significantly greater in the locking compression plate fixation group in the short term (6 weeks, 3 and 6 months), but not after one year. The median time to full weight bearing was significantly shorter in the locking compression plate fixation group (86 vs 116 days, perror, in the femorotibial angle or correction loss between the 2 groups. Locking compression plate fixation obviates the use of plaster casts, enables early mobilisation and bone union, and reduces the numbers with delayed union and the time to full weight bearing. Longer-term studies are needed to evaluate its effect on revarisation and arthropathy.

  12. Bone disease in diabetes

    DEFF Research Database (Denmark)

    Shanbhogue, Vikram V.; Hansen, Stinus; Frost, Morten

    2017-01-01

    Type 1 and type 2 diabetes are generally accepted to be associated with increased bone fracture risk. However, the pathophysiological mechanisms of diabetic bone disease are poorly understood, and whether the associated increased skeletal fragility is a comorbidity or a complication of diabetes...... remains under debate. Although there is some indication of a direct deleterious effect of microangiopathy on bone, the evidence is open to question, and whether diabetic osteopathy can be classified as a chronic, microvascular complication of diabetes remains uncertain. Here, we review the current...... knowledge of potential contributory factors to diabetic bone disease, particularly the association between diabetic microangiopathy and bone mineral density, bone structure, and bone turnover. Additionally, we discuss and propose a pathophysiological model of the effects of diabetic microvascular disease...

  13. Bone regeneration in dentistry

    Science.gov (United States)

    Tonelli, Paolo; Duvina, Marco; Barbato, Luigi; Biondi, Eleonora; Nuti, Niccolò; Brancato, Leila; Rose, Giovanna Delle

    2011-01-01

    Summary The edentulism of the jaws and the periodontal disease represent conditions that frequently leads to disruption of the alveolar bone. The loss of the tooth and of its bone of support lead to the creation of crestal defects or situation of maxillary atrophy. The restoration of a functional condition involves the use of endosseous implants who require adequate bone volume, to deal with the masticatory load. In such situations the bone need to be regenerated, taking advantage of the biological principles of osteogenesis, osteoinduction and osteoconduction. Several techniques combine these principles with different results, due to the condition of the bone base on which we operate changes, the surgical technique that we use, and finally for the bone metabolic conditions of the patient who can be in a state of systemic osteopenia or osteoporosis; these can also affect the result of jaw bone reconstruction. PMID:22461825

  14. Bone stress injuries

    Energy Technology Data Exchange (ETDEWEB)

    Kiuru, M.J.; Pihlajamaeki, H.K.; Ahovuo, J.A. [Helsinki Univ. Central Hospital (Finland). Dept. of Radiology

    2004-05-01

    Bone stress injuries are due to cyclical overuse of the bone. They are relatively common in athletes and military recruits but also among otherwise healthy people who have recently started new or intensive physical activity. Diagnosis of bone stress injuries is based on the patient's history of increased physical activity and on imaging findings. The general symptom of a bone stress injury is stress-related pain. Bone stress injuries are difficult to diagnose based only on a clinical examination because the clinical symptoms may vary depending on the phase of the pathophysiological spectrum in the bone stress injury. Imaging studies are needed to ensure an early and exact diagnosis, because if the diagnosis is not delayed most bone stress injuries heal well without complications.

  15. Bone allografting in children

    Science.gov (United States)

    Sadovoy, M. A.; Kirilova, I. A.; Podorognaya, V. T.; Matsuk, S. A.; Novoselov, V. P.; Moskalev, A. V.; Bondarenko, A. V.; Afanasev, L. M.; Gubina, E. V.

    2017-09-01

    A total of 522 patients with benign and intermediate bone tumors of various locations, aged 1 to 15 years, were operated in the period from 1996 to 2016. To diagnose skeleton tumors, we used clinical observation, X-ray, and, if indicated, tomography and tumor site biopsy. In the extensive bone resection, we performed bone reconstruction with the replacement of a defect with an allograft (bone strips, deproteinized and spongy grafts), sometimes in the combination with bone autografting. After segmental resection, the defects were filled with bone strips in the form of matchstick grafts; the allografts were received from the Laboratory for Tissue Preparation and Preservation of the Novosibirsk Research Institute of Traumatology and Orthopedics. According to the X-ray data, a complete reorganization of bone grafts occurred within 1.5 to 3 years. The long-term result was assessed as good.

  16. Bone scintiscanning updated.

    Science.gov (United States)

    Lentle, B C; Russell, A S; Percy, J S; Scott, J R; Jackson, F I

    1976-03-01

    Use of modern materials and methods has given bone scintiscanning a larger role in clinical medicine, The safety and ready availability of newer agents have led to its greater use in investigating both benign and malignant disease of bone and joint. Present evidence suggests that abnormal accumulation of 99mTc-polyphosphate and its analogues results from ionic deposition at crystal surfaces in immature bone, this process being facilitated by an increase in bone vascularity. There is, also, a component of matrix localization. These factors are in keeping with the concept that abnormal scintiscan sites represent areas of increased osteoblastic activity, although this may be an oversimplification. Increasing evidence shows that the bone scintiscan is more sensitive than conventional radiography in detecting focal disease of bone, and its ability to reflect the immediate status of bone further complements radiographic findings. The main limitation of this method relates to nonspecificity of the results obtained.

  17. BONES WITH BIOCERAMICS

    Directory of Open Access Journals (Sweden)

    Wijianto Wijianto

    2017-01-01

    Full Text Available This paper discuss about ceramics in application as bone implant. Bioceramics for instance Hydroxyapatite, usually is abbreviated with HA or HAp, is a mineral that is very good physical properties as bone replacement in human body. To produce Hydroxyapatite, coating process is used which have good potential as they can exploit the biocompatible and bone bonding properties of the ceramic. There are many advantages and disadvantages of bioceramics as bone implant. Advantages of hydroxyapatite as bone implant are rapidly integrated into the human body, and is most interesting property that will bond to bone forming indistinguishable unions. On contrary, disadvantages of hydroxyapatite as bone implant are poor mechanical properties (in particular fatigue properties mean that hydroxyapatite cannot be used in bulk form for load bearing applications such as orthopaedics and poor adhesion between the calcium phosphate coating and the material implant will occur.

  18. [Anterior interbody fusion of cervical spine with case-plate PCB].

    Science.gov (United States)

    Radek, M; Radek, A; Zapałowicz, K; Maciejczak, A

    2001-01-01

    Two cases with cervical discopathy and radiculopathy are presented. Discectomy and anterior interbody fusion with cage-plate PCB manufactured by French company Scient'x was performed. Authors present the shape of the implant and technical details of implantation. The paper discusses the advantages of the PCB which simplifies and shortens the operation procedure, minimizes the risk of traditional bone graft harvesting and provides immediate stabilization of the operated segment.

  19. Ankle arthrodesis in tubercular arthritis using anterior bridge plating: a report of 2 cases.

    Science.gov (United States)

    Jain, Mantu; Singh, Roop

    2014-06-01

    Ankle arthrodesis is a common procedure for tubercular arthritis in India. However, attaining fusion in osteoporotic bones is difficult to achieve by both external and internal fixation methods described in the literature. We report two cases for ankle arthrodesis using an anterior approach to the ankle and internal fixation with a bridging anteriorly placed AO L/AO T plate. Both ankles were fused. The surgical technique is simple, easily reproducible and gives excellent results. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Nanotechnology and mesenchymal stem cells with chondrocytes in prevention of partial growth plate arrest in pigs

    Czech Academy of Sciences Publication Activity Database

    Plánka, L.; Srnec, R.; Rauser, P.; Starý, D.; Filová, Eva; Jančář, J.; Juhásová, Jana; Křen, J.; Nečas, A.; Gál, P.

    2012-01-01

    Roč. 156, č. 2 (2012), s. 128-134 ISSN 1213-8118 R&D Projects: GA MZd(CZ) NS9896 Institutional research plan: CEZ:AV0Z50390512; CEZ:AV0Z50450515 Institutional support: RVO:68378041 ; RVO:67985904 Keywords : mesenchymal stem cells * growth plate defect * bone bridge Subject RIV: FI - Traumatology, Orthopedics Impact factor: 0.990, year: 2012

  1. Fixation of distal fibular fractures: A biomechanical study of plate fixation techniques.

    Science.gov (United States)

    Marvan, Jiri; Horak, Zdenek; Vilimek, Miloslav; Horny, Lukas; Kachlik, David; Baca, Vaclav

    2017-01-01

    Ankle fractures are complex injuries with variable prognoses that depend upon many factors. The aim of the treatment is to restore the ankle joint biomechanical stability with maximum range of motion. Most ankle fractures are fibular fractures, which have a typical oblique fracture line in the distal fibula located in the area of the tibiofibular syndesmosis. The aim of this study was to simulate numerically several fixation techniques of the distal fibular fractures, evaluate their stability, determine their impact on surrounding tissue load, and correlate the results to clinical treatment experience. The following three models of fibular fracture fixation were used: (a) plate fixation with three screws attached above/below and lag screws, (b) plate fixation with two screws attached above/below and lag screws, and (c) three lag screws only. All three fracture fixation models were analyzed according to their use in both healthy physiological bone and osteoporotic bone tissue. Based on the results of Finite Element Analysis for these simulations, we found that the most appropriate fixation method for Weber-B1 fibular fractures was an unlocked plate fixation using six screws and lag screws, both in patients with physiological and osteoporotic bone tissue. Conversely, the least appropriate fixation method was an unlocked plate fixation with four screws and lag screws. Although this fixation method reduces the stress on patients during surgery, it greatly increased loading on the bone and, thus, the risk of fixation failure. The final fixation model with three lag screws only was found to be appropriate only for very limited indications.

  2. Defects of the vertebral end plate: implications for disc degeneration depend on size.

    Science.gov (United States)

    Zehra, Uruj; Flower, Luke; Robson-Brown, Katharine; Adams, Michael A; Dolan, Patricia

    2017-05-01

    Bony vertebral end plates must be porous to allow metabolite transport into the disc, and yet strong to resist high intradiscal pressure (IDP). End plate defects may therefore have nutritional and mechanical consequences for the disc, depending on their size and type. We hypothesize that broad, diffuse defects are more closely associated with disc decompression and degeneration than are focal Schmorl's node-type defects. This study aimed to determine how the size and type of end plate defects are related to decompression and degeneration in the adjacent intervertebral disc. Mechanical, histologic, and micro-computed tomographic investigations were carried out in cadaver spines. The study involved 40 motion segments (T8-T9 to L4-L5) dissected from 23 cadavers aged 48-98 years. Intradiscal stresses were measured, under 1 kN compression, by pulling a pressure transducer along the disc's midsagittal diameter. The resulting "stress profiles" revealed nucleus pressure (IDP) and maximum stresses in the anterior and posterior annulus. Micro-computed tomography was then used to examine all 40 discs, with 5 mm of adjacent bone on either side, so that end plate defects could be characterized at a resolution of 35 µm. Cross-sectional area (in the transverse plane), volume, location, and morphologic type were determined for all bony defects in the 80 end plates. Finally, discs from each motion segment (with hyaline cartilage and bone attached) were sectioned (undecalcified) at 7 µm for histology to allow degeneration to be assessed. Substantial defects were identified in 24 of 40 specimens (35 of 80 end plates). Of these, 83% was centrally located, and 17% was laterally located. Defects occurred more frequently in male than female specimens (p=.043), and were more common in thoracic than lumbar end plates (p=.002), although lumbar defects were greater in volume (p=.05). Defect area and volume increased with decreasing IDP, with decreasing peak stress in the annulus, and

  3. Reverse Less Invasive Stabilization System (LISS) Plating for Proximal Femur Fractures in Poliomyelitis Survivors: A Report of Two Cases.

    Science.gov (United States)

    Yao, Chen; Jin, Dongxu; Zhang, Changqing

    2017-11-15

    BACKGROUND Poliomyelitis is a neuromuscular disease which causes muscle atrophy, skeletal deformities, and disabilities. Treatment of hip fractures on polio-affect limbs is unique and difficult, since routine fixation methods like nailing may not be suitable due to abnormal skeletal structures. CASE REPORT We report one femoral neck fracture and one subtrochanteric fracture in polio survivors successfully treated with reverse less invasive stabilization system (LISS) plating technique. Both fractures were on polio-affected limbs with significant skeletal deformities and low bone density. A contralateral femoral LISS plate was applied upside down to the proximal femur as an internal fixator after indirect or direct reduction. Both patients had uneventful bone union and good functional recovery. CONCLUSIONS Reverse LISS plating is a safe and effective technique to treat hip fractures with skeletal deformities caused by poliomyelitis.

  4. Leptin differentially regulates chondrogenesis in mouse vertebral and tibial growth plates.

    Science.gov (United States)

    Yu, Bo; Jiang, Kaibiao; Chen, Bin; Wang, Hantao; Li, Xinfeng; Liu, Zude

    2017-05-31

    Leptin plays an important role in mediating chondrogenesis of limb growth plate. Previous studies suggest that bone structures and development of spine and limb are different. The expression of Ob-Rb, the gene that encodes leptin receptors, is vertebral and appendicular region-specific, suggesting the regulation of leptin on VGP and TGP chondrogenesis may be very different. The aim of the present study was to investigate the differential regulation of leptin on the chondrogenesis of vertebral growth plate (VGP) and tibial growth plate (TGP). We compared the VGP and TGP from wild type (C57BL/6) and leptin-deficient (ob/ob) mice. We then generated primary cultures of TGP and VGP chondrocytes. By treating the primary cells with different concentrations of leptin in vitro, we analyzed proliferation and apoptosis of the primary chondrocytes from TGP and VGP. We further measured expression of chondrogenic-related genes in these cells that had been incubated with different doses of leptin. Leptin-deficient mice of 8-week-old had shorter tibial and longer vertebral lengths than the wide type mice. Disturbed columnar structure was observed for TGP but not for VGP. In primary chondrocyte cultures, leptin inhibited VGP chondrocyte proliferation but promoted their apoptosis. Collagen IIA and aggrecan mRNA, and the protein levels of proliferation- and chondrogenesis-related markers, including PCNA, Sox9, and Smad4, were downregulated by leptin in a dose-dependent manner. In contrast, leptin stimulated the proliferation and chondrogenic differentiation of TGP chondrocytes at physiological levels (i.e., 10 and 50 ng/mL) but not at high levels (i.e., 100 and 1000 ng/mL). Leptin exerts a stimulatory effect on the proliferation and chondrogenic differentiation of the long bone growth plate but an inhibitory effect on the spine growth plate. The ongoing study will shed light on the regulatory mechanisms of leptin in bone development and metabolism.

  5. Silicon-micromachined microchannel plates

    Energy Technology Data Exchange (ETDEWEB)

    Beetz, Charles P. E-mail: NanoSystem@aol.com; Boerstler, Robert; Steinbeck, John; Lemieux, Bryan; Winn, David R. E-mail: winn@fair1.fairfield.edu

    2000-03-11

    Microchannel plates (MCP) fabricated from standard silicon wafer substrates using a novel silicon micromachining process, together with standard silicon photolithographic process steps, are described. The resulting SiMCP microchannels have dimensions of {approx}0.5 to {approx}25 {mu}m, with aspect ratios up to 300, and have the dimensional precision and absence of interstitial defects characteristic of photolithographic processing, compatible with positional matching to silicon electronics readouts. The open channel areal fraction and detection efficiency may exceed 90% on plates up to 300 mm in diameter. The resulting silicon substrates can be converted entirely to amorphous quartz (qMCP). The strip resistance and secondary emission are developed by controlled depositions of thin films, at temperatures up to 1200 deg. C, also compatible with high-temperature brazing, and can be essentially hydrogen, water and radionuclide-free. Novel secondary emitters and cesiated photocathodes can be high-temperature deposited or nucleated in the channels or the first strike surface. Results on resistivity, secondary emission and gain are presented.

  6. Silicon-micromachined microchannel plates

    Science.gov (United States)

    Beetz, Charles P.; Boerstler, Robert; Steinbeck, John; Lemieux, Bryan; Winn, David R.

    2000-03-01

    Microchannel plates (MCP) fabricated from standard silicon wafer substrates using a novel silicon micromachining process, together with standard silicon photolithographic process steps, are described. The resulting SiMCP microchannels have dimensions of ˜0.5 to ˜25 μm, with aspect ratios up to 300, and have the dimensional precision and absence of interstitial defects characteristic of photolithographic processing, compatible with positional matching to silicon electronics readouts. The open channel areal fraction and detection efficiency may exceed 90% on plates up to 300 mm in diameter. The resulting silicon substrates can be converted entirely to amorphous quartz (qMCP). The strip resistance and secondary emission are developed by controlled depositions of thin films, at temperatures up to 1200°C, also compatible with high-temperture brazing, and can be essentially hydrogen, water and radionuclide-free. Novel secondary emitters and cesiated photocathodes can be high-temperature deposited or nucleated in the channels or the first strike surface. Results on resistivity, secondary emission and gain are presented.

  7. Silicon-micromachined microchannel plates

    International Nuclear Information System (INIS)

    Beetz, Charles P.; Boerstler, Robert; Steinbeck, John; Lemieux, Bryan; Winn, David R.

    2000-01-01

    Microchannel plates (MCP) fabricated from standard silicon wafer substrates using a novel silicon micromachining process, together with standard silicon photolithographic process steps, are described. The resulting SiMCP microchannels have dimensions of ∼0.5 to ∼25 μm, with aspect ratios up to 300, and have the dimensional precision and absence of interstitial defects characteristic of photolithographic processing, compatible with positional matching to silicon electronics readouts. The open channel areal fraction and detection efficiency may exceed 90% on plates up to 300 mm in diameter. The resulting silicon substrates can be converted entirely to amorphous quartz (qMCP). The strip resistance and secondary emission are developed by controlled depositions of thin films, at temperatures up to 1200 deg. C, also compatible with high-temperature brazing, and can be essentially hydrogen, water and radionuclide-free. Novel secondary emitters and cesiated photocathodes can be high-temperature deposited or nucleated in the channels or the first strike surface. Results on resistivity, secondary emission and gain are presented

  8. Complications of massive allograft reconstruction for bone tumors

    Directory of Open Access Journals (Sweden)

    Abolhasan Borjian

    2006-11-01

    Full Text Available BACKGROUND: Since the evolution of multi-drug chemotherapy and radiotherapy and new sophisticated surgical techniques, limb salvage and reconstruction, rather than amputation, has become the preferred treatment for patients with bone tumors. One option is allograft replacement. Although allograft has several advantages, it is not without complications. This study was performed to observe these complications in a group of patients treated with allograft replacement for bone tumor resection. The purpose was to gain an overview of the factors predisposing to these complications to minimize their occurrence. METHODS: This retrospective study was performed on patients with benign aggressive and malignant bone tumors undergoing limb reconstruction with allograft between 1997 and 2005 in Al-Zahra and Kashani Hospitals in Isfahan, Iran. Data was collected from patient files, clinical notes, radiographs and a recent physical examination. Complications including local recurrence, fracture of allograft, fixation failure, nonunion, infection, skin necrosis and neurological damage were recorded. RESULTS: Sixty patients including 39 males and 21 females were studied. The mean age of patients was 23 ± 11.7 years. The mean follow-up interval was 28.1 ± 12.4 months (mean ± SD. Complications were allograft fracture in 20%, local recurrence in 16%, fixation failure in 11%, nonunion in 6%, infection in 6%, skin necrosis in 6%, and peroneal nerve palsy in 1% of cases. Most local recurrences (60% were those with a mal-performed biopsy. Most allograft fractures occurred when a short plate was used. CONCLUSIONS: Allograft replacement for bone tumors remains a valid option. To avoid complications, biopsy should be done by a trained surgeon in bone oncology. A long plate is recommended for fixation. Sterility and graft processing must be optimal. Autogenous bone graft must be added at host-allograft junction. KEY WORDS: Bone tumors, bone allograft, limb

  9. A novel osteogenesis technique: The expansible guided bone regeneration

    Directory of Open Access Journals (Sweden)

    Osama Zakaria

    2012-12-01

    Full Text Available Guided bone regeneration is a unique osteogenesis technique that requires a barrier membrane under periosteum to create space for bone regeneration. However, creating sizeable spaces is clinically not commonly feasible. A titanium plate and a thin silicone membrane were surgically layered on each calvaria of eight rabbits. Then, the periphery of the silicone membrane was fixed by a plastic ring to the underlying bone using titanium micro screws. After 1 week, a 5-mm-length titanium screw was used to elevate the titanium plate, which in turn elevated the silicone membrane together with overlying soft tissue in a rate of 1 mm/day for 5 days to create a secluded space. Animals were killed at 2 months (n = 4, group 1 and 4 months (n = 4, group 2 after the elevation. Histological and microradiographical analyses demonstrated creation of an amount of de novo bone formation (68.2 ± 22 mm3 in group 1 and 70.3 ± 14 mm3 in group 2 in the sizeable created spaces (207.1 ± 31 mm3 in group 1 and 202 ± 21 mm3 in group 2 without exposure of the device. This novel osteogenesis technique, “expansible guided bone regeneration,” created a substantial in vivo incubator without applying growth factors or osteoprogenitor cells. Creating a growing space over the secluded surface allowed the development of normal biological healing process occurring on the bone surface into a regenerative process, generating bone outside the genetically determined skeletal bone. This technique is a new tissue engineering approach stimulating endogenous tissue repair without applying cells or factors exogenously.

  10. Delayed Reduction of Nasal Bone Fractures.

    Science.gov (United States)

    Yoon, Han Young; Han, Dong Gil

    2016-06-01

    Nasal bone fractures are managed by closed reduction within the 2-week period, and are managed by secondary correction after this time. There is little literature on the delayed reduction for nasal bone fractures beyond the 2-week duration. We report our experience with nasal fractures, which were reduced beyond this period. A retrospective review was performed for all patients who had undergone closed reduction of isolated nasal bone fracture. Patients were included for having undergone reduction of nasal bone fractures at or more than 2 weeks after the injury. Medical records were reviewed for demographic information, injury mechanism, fracture type, delay in treatment, and cause for delay. Postoperative outcomes were evaluated using computed tomography images. The review identified 10 patients. The average reduction time was 22.1 days. Five of patients underwent reduction between days 15 and 20, and the remaining five patients underwent reduction between days 21 and 41. The postoperative outcomes were excellent in 8 patients and good in 2 patients. Outcomes were superior for nasal fractures with displaced end plates and multiple fracture segments. Our study results appears to support delayed reduction of isolated nasal fractures in the presence of factors that delay bony reunion.

  11. Immediate placement of a porous-tantalum, trabecular metal-enhanced titanium dental implant with demineralized bone matrix into a socket with deficient buccal bone: a clinical report.

    Science.gov (United States)

    Bencharit, Sompop; Byrd, Warren C; Hosseini, Bashir

    2015-04-01

    A missing or deficient buccal alveolar bone plate is often an important limiting factor for immediate implant placement. Titanium dental implants enhanced with porous tantalum-based trabecular metal material (PTTM) are designed for osseoincorporation, a combination of vascularized bone ingrowth and osseointegration (bone on-growth). Demineralized bone matrix (DBM) contains growth factors with good handling characteristics. However, the combination of these 2 materials in facial alveolar bone regeneration associated with immediate implant therapy has not been reported. A 65-year-old Asian woman presented with a failing central incisor. Most of the buccal alveolar bone plate of the socket was missing. A PTTM enhanced implant was immediately placed with DBM. Cone beam computed tomography scans 12 months after the insertion of the definitive restoration showed regeneration of buccal alveolar bone. A combination of a PTTM enhanced implant, DBM, and a custom healing abutment may have an advantage in retaining biologically active molecules and form a scaffold for neovascularization and osteogenesis. This treatment protocol may be a viable option for immediate implant therapy in a failed tooth with deficient buccal alveolar bone. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Long-term results with the uncemented thrust plate prosthesis (TPP).

    Science.gov (United States)

    Huggler, A H; Jacob, H A; Bereiter, H; Haferkorn, M; Ryf, C; Schenk, R

    1993-01-01

    The long-term clinical results of a novel concept for total joint replacement called the Thrust Plate Prosthesis (TPP) are presented. Only a restricted number of patients were provided with this new prosthesis (115 at the Orthopedic Department, Canton Hospital, Chur, and 47 at the Department of Orthopedic Surgery, University of Zurich). All patients have undergone clinical and radiological follow-up covering a period from 1980 to 1991. The basic feature of the Thrust Plate Prosthesis is the direct load transfer to the medial cortical bone of the femoral neck, and this has been unchanged since 1978. Titanium alloy has been used since 1986. The good clinical and radiological results are confirmed by a histological examination of an 8-year-old implant: In the crucial area of load transfer newly formed bone can be seen in direct contact with the thrust plate without fibrous tissue in between. The clinical results and histological findings have confirmed the validity of the biomechanical principle of the TPP. The TPP is therefore to be considered a true alternative to the conventional hip prosthesis. In contrast to the conventional intramedullary anchored stem prosthesis the TPP requires the removal of a minimum amount of bone stock, which is certainly important in young patients.

  13. [Bone homeostasis and Mechano biology.

    Science.gov (United States)

    Nakashima, Tomoki

    The weight-bearing exercises help to build bones and to maintain them strength. Bone is constantly renewed by the balanced action of osteoblastic bone formation and osteoclastic bone resorption both of which mainly occur at the bone surface. This restructuring process called "bone remodeling" is important not only for normal bone mass and strength, but also for mineral homeostasis. Bone remodeling is stringently regulated by communication between bone component cells such as osteoclasts, osteoblasts and osteocytes. An imbalance of this process is often linked to various bone diseases. During bone remodeling, resorption by osteoclasts precedes bone formation by osteoblasts. Based on the osteocyte location within the bone matrix and the cellular morphology, it is proposed that osteocytes potentially contribute to the regulation of bone remodeling in response to mechanical and endocrine stimuli.

  14. SHP2 regulates chondrocyte terminal differentiation, growth plate architecture and skeletal cell fates.

    Directory of Open Access Journals (Sweden)

    Margot E Bowen

    Full Text Available Loss of PTPN11/SHP2 in mice or in human metachondromatosis (MC patients causes benign cartilage tumors on the bone surface (exostoses and within bones (enchondromas. To elucidate the mechanisms underlying cartilage tumor formation, we investigated the role of SHP2 in the specification, maturation and organization of chondrocytes. Firstly, we studied chondrocyte maturation by performing RNA-seq on primary chondrocyte pellet cultures. We found that SHP2 depletion, or inhibition of the ERK1/2 pathway, delays the terminal differentiation of chondrocytes from the early-hypertrophic to the late-hypertrophic stage. Secondly, we studied chondrocyte maturation and organization in mice with a mosaic postnatal inactivation of Ptpn11 in chondrocytes. We found that the vertebral growth plates of these mice have expanded domains of early-hypertrophic chondrocytes that have not yet terminally differentiated, and their enchondroma-like lesions arise from chondrocytes displaced from the growth plate due to a disruption in the organization of maturation and ossification zones. Furthermore, we observed that lesions from human MC patients also display disorganized chondrocyte maturation zones. Next, we found that inactivation of Ptpn11 in Fsp1-Cre-expressing fibroblasts induces exostosis-like outgrowths, suggesting that loss of SHP2 in cells on the bone surface and at bone-ligament attachment sites induces ectopic chondrogenesis. Finally, we performed lineage tracing to show that exostoses and enchondromas in mice likely contain mixtures of wild-type and SHP2-deficient chondrocytes. Together, these data indicate that in patients with MC, who are heterozygous for inherited PTPN11 loss-of-function mutations, second-hit mutations in PTPN11 can induce enchondromas by disrupting the organization and delaying the terminal differentiation of growth plate chondrocytes, and can induce exostoses by causing ectopic chondrogenesis of cells on the bone surface. Furthermore, the

  15. Minimally invasive osteosynthesis of distal tibial fractures using anterolateral locking plate: Evaluation of results and complications.

    Science.gov (United States)

    Lakhotia, Devendra; Sharma, Gaurav; Khatri, Kavin; Kumar, G-N; Sharma, Vijay; Farooque, Kamran

    2016-01-01

    Soft tissue healing is of paramount importance in distal tibial fractures for a successful outcome. There is an increasing trend of using anterolateral plate due to an adequate soft tissue cover on ante- rolateral distal tibia. The aim of this study was to evaluate the results and complications of minimally invasive anterolateral locking plate in distal tibial fractures. This is a retrospective study of 42 patients with distal tibial fractures treated with minimally invasive anterolateral tibial plating. This study evaluates the bone and soft tissue healing along with emphasis on complications related to bone and soft tissue healing. Full weight bearing was allowed in mean time period of 4.95 months (3-12 months). A major local complication of a wound which required revision surgery was seen in one case. Minor complications were identified in 9 cases which comprised 4 cases of marginal necrosis of the surgical wound, 1 case of superficial infection, 1 case of sensory disturbance over the anterolateral foot, 1 case of muscle hernia and 2 cases of delayed union. Mean distance between the posterolateral and anterolateral incision was 5.7 cm (4.5-8 cm). The minimally invasive distal tibial fixation with anterolateral plating is a safe method of stabilization. Distance between anterolateral and posterolateral incision can be placed less than 7 cm apart depending on fracture pattern with proper surgical timing and technique.

  16. Intramedullary nailing and plate osteosynthesis for fractures of the distal metaphyseal tibia and fibula.

    Science.gov (United States)

    Krishan, Ajay; Peshin, Chetan; Singh, Dara

    2009-12-01

    To assess the results of concurrent intramedullary nailing plus plate osteosynthesis for fractures of the distal tibia and fibula. 15 men and 10 women (mean age, 35 years) with concurrent fractures of the distal tibia and fibula underwent intramedullary nailing (for the tibia) and plate osteosynthesis (for the fibula). 17 fractures were type A1, 6 type A2, and 2 type A3. Compound type IIIB or more extensive fractures were excluded. The mean follow-up duration was 2 years. The mean time to bone union was 20 weeks. Six patients underwent dynamisation and 4 bone grafting. Two patients had malalignment (angulation of >5 degrees in any plane), but none was rotational. No patient had shortening, hardware breakdown, or deep-seated infection. Two patients had superficial cellulitis at the site of the distal locking screws. Concurrent intramedullary nailing and plate osteosynthesis for fractures of the distal tibia and fibula is effective in preventing malalignment. Plate osteosynthesis for the fibula provides additional stability even when a single distal locking bolt is used to fix the intramedullary nail to the tibia.

  17. Toxicokinetics of bone lead.

    Science.gov (United States)

    Rabinowitz, M B

    1991-02-01

    This article discusses bone as a source of lead to the rest of the body and as a record of past lead exposure. Bone lead levels generally increase with age at rates dependent on the skeletal site and lead exposure. After occupational exposure, the slow decline in blood lead, a 5- to 19-year half-life, reflects the long skeletal half-life. Repeated measurements of bone lead demonstrate the slow elimination of lead from bone. Stable isotope ratios have revealed many details of skeletal uptake and subsequent release. The bulk turnover rates for compact bone are about 2% per year and 8% for spine. Turnover activity varies with age and health. Even though lead approximates calcium, radium, strontium, barium, fluorine, and other bone seekers, the rates for each are different. A simple, two-pool (bone and blood) kinetic model is presented with proposed numerical values for the changes in blood lead levels that occur with changes in turnover rates. Two approaches are offered to further quantify lead turnover. One involves a study of subjects with known past exposure. Changes in the ratio of blood lead to bone lead with time would reflect the course of bone lead availability. Also, stable isotopes and subjects who move from one geographical area to another offer opportunities. Sequential isotope measurements would indicate how much of the lead in blood is from current exposure or bone stores, distinct from changes in absorption or excretion.

  18. Excitation and Characterization of Chladni Plate Patterns

    Science.gov (United States)

    Bourke, Shannon; Behringer, Ernest

    2011-04-01

    When a thin metal plate with a small amount of sand on it is made to vibrate, aesthetically pleasing sand patterns can form along the nodal lines of the plate. These symmetric patterns are called Chladni Patterns. Students taking PHY 101 Physical Science in the Arts at Eastern Michigan University create these patterns by pulling a violin bow across the edge of a plate, or by using a mechanical oscillator to drive the center of a plate. These two methods only allow a small subset of all possible points on the plate to be excited. We designed and built an electronic device that allows its user to excite the plate at any point. We present patterns created with this electronic device and other methods, and describe ways to model the observed patterns.

  19. Plantar versus dorsomedial locked plating for Lapidus arthrodesis: a biomechanical comparison.

    Science.gov (United States)

    Klos, Kajetan; Simons, Paul; Hajduk, Anne-Sophie; Hoffmeier, Konrad Leopold; Gras, Florian; Fröber, Rosemarie; Hofmann, Gunther O; Mückley, Thomas

    2011-11-01

    Lapidus arthrodesis with a plate and a compression screw is an established procedure in hallux valgus surgery. The present study was performed to investigate the potential benefit of a compression screw combined with a plantarly applied angle-stable, anatomically precontoured plate or a dorsomedially applied angle-stable plate. In six pairs of human cadaver specimens, one specimen each was randomized to receive a dorsomedial H-shaped plate, while the other received a plantar plate. Bone mineral density was measured with peripheral quantitative computed tomography. The specimens were loaded quasi-statically, followed by cyclic loading. Finally, they were loaded to failure. In the static tests, stiffness and range of motion (ROM) data were obtained. In the cyclic tests, the constructs' displacement was studied. In the load-to-failure test, stiffness and maximum load to failure were measured. The two groups did not differ significantly with regard to BMD (p = 0.25). Any significant differences observed were in favor of the plantar constructs, which had greater initial stiffness (p = 0.028) and final stiffness (p = 0.042), a smaller ROM (p = 0.028), and a greater load to failure (p = 0.043). There was no significant difference regarding displacement (p = 0.14). In the static tests, the plantar angle-stable plate construct was superior to the dorsomedial angle-stable plate construct. Plantar plating appears to offer biomechanical benefit. Clinical studies will be required to show whether this translates into earlier resumption of weightbearing and into lower rates of nonunion.

  20. Histological characterization of denticulate palatal plates in an Early Permian dissorophoid

    Directory of Open Access Journals (Sweden)

    Bryan M. Gee

    2017-08-01

    Full Text Available Denticles are small, tooth-like protrusions that are commonly found on the palate of early tetrapods. Despite their widespread taxonomic occurrence and similar external morphology to marginal teeth, it has not been rigorously tested whether denticles are structurally homologous to true teeth with features such as a pulp cavity, dentine, and enamel, or if they are bony, tooth-like protrusions. Additionally, the denticles are known to occur not only on the palatal bones but also on a mosaic of small palatal plates that is thought to have covered the interpterygoid vacuities of temnospondyls through implantation in a soft tissue covering; however, these plates have never been examined beyond a simple description of their position and external morphology. Accordingly, we performed a histological analysis of these denticulate palatal plates in a dissorophoid temnospondyl in order to characterize their microanatomy and histology. The dentition on these palatal plates has been found to be homologous with true teeth on the basis of both external morphology and histological data through the identification of features such as enamel and a pulp cavity surrounded by dentine. In addition, patterns of tooth replacement and ankylosis support the hypothesis of structural homology between these tiny teeth on the palatal plates and the much larger marginal dentition. We also provide the first histological characterization of the palatal plates, including documentation of abundant Sharpey’s fibres that provide a direct line of evidence to support the hypothesis of soft tissue implantation. Finally, we conducted a survey of the literature to determine the taxonomic distribution of these plates within Temnospondyli, providing a broader context for the presence of palatal plates and illustrating the importance of maintaining consistency in nomenclature.

  1. Delayed Foreign Body Reaction Caused by Bioabsorbable Plates Used for Maxillofacial Fractures

    Directory of Open Access Journals (Sweden)

    Hong Bae Jeon

    2016-01-01

    Full Text Available BackgroundBioabsorbable plates and screws are commonly used to reduce maxillofacial bones, particularly in pediatric patients because they degrade completely without complications after bone healing. In this study, we encountered eight cases of a delayed foreign body reaction after surgical fixation with bioabsorbable plates and screws.MethodsA total of 234 patients with a maxillofacial fracture underwent surgical treatment from March 2006 to October 2013, in which rigid fixation was achieved with the Inion CPS (Inion, Tampere, Finland plating system in 173 patients and Rapidsorb (Synthes, West Chester, PA, USA in 61 patients. Their mean age was 35.2 years (range, 15-84 years. Most patients were stabilized with two- or three-point fixation at the frontozygomatic suture, infraorbital rim, and anterior wall of the maxilla.ResultsComplications occurred in eight (3.4% of 234 patients, including palpable, fixed masses in six patients and focal swelling in two patients. The period from surgical fixation to the onset of symptoms was 9-23 months. Six patients with a mass underwent secondary surgery for mass removal. The masses contained fibrous tissue with a yellow, grainy, cloudy fluid and remnants of an incompletely degraded bioabsorbable plate and screws. Their histological findings demonstrated a foreign body reaction.ConclusionsInadequate degradation of bioabsorbable plates caused a delayed inflammatory foreign body reaction requiring secondary surgery. Therefore, it is prudent to consider the possibility of delayed complications when using bioabsorbable plates and surgeons must conduct longer and closer follow-up observations.

  2. New fast license plate location method

    Science.gov (United States)

    Li, Wei; Huang, Xinhan; Wang, Min; Chen, Xi

    2001-09-01

    This paper presents a new fast license plate location method based on gray-scale image. According to the vertical edge features of the characters on Chinese license plate, it applies the threshold iteration to realize license plate location in complicated background. The algorithm satisfies the requirements of a real-time system and has good robustness. The precision of segmentation has been close to 98%.

  3. Anisotropic magnetocapacitance in ferromagnetic-plate capacitors

    Science.gov (United States)

    Haigh, J. A.; Ciccarelli, C.; Betz, A. C.; Irvine, A.; Novák, V.; Jungwirth, T.; Wunderlich, J.

    2015-04-01

    The capacitance of a parallel-plate capacitor can depend on the applied magnetic field. Previous studies have identified capacitance changes induced via classical Lorentz force or spin-dependent Zeeman effects. Here we measure a magnetization direction-dependent capacitance in parallel-plate capacitors where one plate is a ferromagnetic semiconductor, gallium manganese arsenide. This anisotropic magnetocapacitance is due to the anisotropy in the density of states dependent on the magnetization through the strong spin-orbit interaction.

  4. Evaluation of korzincalloy prepared by Hohman Plating

    Energy Technology Data Exchange (ETDEWEB)

    Korinko, P. S. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hollingshad, A. N. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-07-17

    A commercial vendor, Hohman Plating performed contract engineering work to determine the feasibility of producing pin hole free KorZincAlloy bronze material used for zinc gettering. Samples were tested for Sn plating thickness, heat treatability, and chemistry prior to being subjected to a standardized zinc exposure. The samples absorbed zinc and were examined using visual and scanning electron microscopy. Hohman Plating successfully produced KZA that met the target composition, was pin hole free, and was an effective zinc getter.

  5. 431K/CD vehicle number plates

    CERN Multimedia

    GS Department

    2009-01-01

    The Green Plates Service, which is responsible for issuing the 431K/CD vehicle number plates , wishes to apologise for the delay in processing applications over the past weeks. The delay is outside the Service’s control, as it is due to the recent introduction of new rules governing the vehicle registration process in France. Normal service will be resumed as soon as possible. Thank you for your understanding. GS-SEM-LS – Green Plates Service

  6. Strain resolving method of composite plane plates

    Directory of Open Access Journals (Sweden)

    Ion FUIOREA

    2011-06-01

    Full Text Available The paper deals with the extension of isotropic plates problem to the case of composite plates. In order to perform it, the Kirchhoff-Love hypotheses were “softened” by some additional ones. Considering the constitutive laws for composite materials the stress functions were eliminated by using Cauchy equations. As a result a partial derivative equation in displacements was obtained. Finally the boundary condition formulation was extended for the case of complex composite plates.

  7. Predicting impact induced delaminations in composite plates

    Science.gov (United States)

    Wu, Hsi-Yung T.; Springer, George S.

    1988-01-01

    A method is presented which can be used to estimate the dimensions of delaminations in fiber reinforced composite plates impacted by a solid object. The impact occurs at low velocity such that the impactor does not penetrate the surface of the plate. Comparisons between measured and calculated delamination lengths and widths are given. The use of the method in the design of impact resistant plates is discussed.

  8. REVISION SURGERY IN PATIENTS WITH SCOLIOSIS OPERATED WITH PLATE ENDOCORRECTORS

    Directory of Open Access Journals (Sweden)

    S. V. Kolesov

    2012-01-01

    Full Text Available The authors presented 19 clinical observations of patients undergoing surgery at the primary idiopathic scoliosis using plate endocorrectors. The following characteristics were determined: the fixation of posterior elements of the spine there is no possibility of adequate derotation scoliotic vertebrae arc and require extensive fixation of the spine (Th2-L4, significantly reducing the functional activity of the patients. The lack of the fusion is accompanied by system micromotion, causes the instability of the upper pole of the metal construction and provokes the formation of a fistula. The presence of fibrous scar, and later - bone block, doesn’t allow to realize the lengthening effect during the patient’s growth and causes the development of Crankshaft-phenomenon, the correction of which requires a long, traumatic, multi-stage surgery.

  9. Differences of bone healing in metaphyseal defect fractures between osteoporotic and physiological bone in rats.

    Science.gov (United States)

    Thormann, Ulrich; El Khawassna, Thaqif; Ray, Seemun; Duerselen, Lutz; Kampschulte, Marian; Lips, Katrin; von Dewitz, Helena; Heinemann, Sascha; Heiss, Christian; Szalay, Gabor; Langheinrich, Alexander C; Ignatius, Anita; Schnettler, Reinhard; Alt, Volker

    2014-03-01

    Discrepancies in bone healing between osteoporotic and non-osteoporotic bone remain uncertain. The focus of the current work is to evaluate potential healing discrepancies in a metaphyseal defect model in rat femora. Female Sprague-Dawley rats were either ovariectomized (OVX, n=14) and combined with a calcium-, phosphorus- and vitamin D3-, soy- and phytoestrogen-free diet or received SHAM operation with standard diet rat (SHAM, n=14). Three months post-ovariectomy, DEXA measurement showed a reduction of bone mineral density reflecting an osteoporotic bone status in OVX rats. Rats then underwent a 3 mm wedge-shaped osteotomy at the distal metaphyseal area of the left femur stabilized with a T-shaped mini-plate and allowed to heal for 6 weeks. Biomechanical competence by means of a non-destructive three-point bending test showed significant lower flexural rigidity in the OVX rats at 3 mm lever span compared to SHAM animals (p=0.048) but no differences at 10 mm lever span. Microcomputer tomography (μCT) showed bridging cortices and consolidation of the defect in both groups, however, no measurable differences were found in either total ossified tissue or vascular volume fraction. Furthermore, histology showed healing discrepancies that were characterized by cartilaginous remnant and more unmineralized tissue presence in the OVX rats compared to more mature consolidation appearance in the SHAM group. In summary, bone defect healing in metaphyseal bone slightly differs between osteoporotic and non-osteoporotic bone in the current 3 mm defect model in both 3mm lever span biomechanical testing and histology. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Reliability assessment of different plate theories for elastic wave propagation analysis in functionally graded plates.

    Science.gov (United States)

    Mehrkash, Milad; Azhari, Mojtaba; Mirdamadi, Hamid Reza

    2014-01-01

    The importance of elastic wave propagation problem in plates arises from the application of ultrasonic elastic waves in non-destructive evaluation of plate-like structures. However, precise study and analysis of acoustic guided waves especially in non-homogeneous waveguides such as functionally graded plates are so complicated that exact elastodynamic methods are rarely employed in practical applications. Thus, the simple approximate plate theories have attracted much interest for the calculation of wave fields in FGM plates. Therefore, in the current research, the classical plate theory (CPT), first-order shear deformation theory (FSDT) and third-order shear deformation theory (TSDT) are used to obtain the transient responses of flexural waves in FGM plates subjected to transverse impulsive loadings. Moreover, comparing the results with those based on a well recognized hybrid numerical method (HNM), we examine the accuracy of the plate theories for several plates of various thicknesses under excitations of different frequencies. The material properties of the plate are assumed to vary across the plate thickness according to a simple power-law distribution in terms of volume fractions of constituents. In all analyses, spatial Fourier transform together with modal analysis are applied to compute displacement responses of the plates. A comparison of the results demonstrates the reliability ranges of the approximate plate theories for elastic wave propagation analysis in FGM plates. Furthermore, based on various examples, it is shown that whenever the plate theories are used within the appropriate ranges of plate thickness and frequency content, solution process in wave number-time domain based on modal analysis approach is not only sufficient but also efficient for finding the transient waveforms in FGM plates. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Locking screw-plate interface stability in carbon-fibre reinforced polyetheretherketone proximal humerus plates.

    Science.gov (United States)

    Hak, David J; Fader, Ryan; Baldini, Todd; Chadayammuri, Vivek B S

    2017-09-01

    Carbon-fibre reinforced polyetheretherketone (CFR-PEEK) plates have recently been introduced for proximal humerus fracture treatment. The purpose of this study was to compare the locking screw-plate interface stability in CFR-PEEK versus stainless steel (SS) proximal humerus plates. Locking screw mechanical stability was evaluated independently in proximal and shaft plate holes. Stiffness and load to failure were tested for three conditions: (1) on-axis locking screw insertion in CFR-PEEK versus SS plates, (2) on-axis locking screw insertion, removal, and reinsertion in CFR-PEEK plates, and (3) 10-degree off-axis locking screw insertion in CFR-PEEK plates. Cantilever bending at a rate of 1 mm/minute was produced by an Instron machine and load-displacement data recorded. Shaft locking screw load to failure was significantly greater in CFR-PEEK plates compared to SS plates (746.4 ± 89.7 N versus 596.5 ± 32.6 N, p PEEK plates (p PEEK plates. The mechanical stability of locking screws in CFR-PEEK plates is comparable or superior to locking screws in SS plates.

  12. Line Heat-Source Guarded Hot Plate

    Data.gov (United States)

    Federal Laboratory Consortium — Description:The 1-meter guarded hot-plate apparatus measures thermal conductivity of building insulation. This facility provides for absolute measurement of thermal...

  13. Embedded adhesive connection for laminated glass plates

    DEFF Research Database (Denmark)

    Hansen, Jens Zangenberg; Poulsen, S.H.; Bagger, A.

    2012-01-01

    The structural behavior of a new connection design, the embedded adhesive connection, used for laminated glass plates is investigated. The connection consists of an aluminum plate encapsulated in-between two adjacent triple layered laminated glass plates. Fastening between glass and aluminum...... is ensured using a structural adhesive. At first, the elastic and viscoelastic material properties of the adhesive are identified where the influence of load-rate and failure properties are also examined. Through an inverse analysis using the finite element method, the experimental observations...... usage in a design situation. The embedded connection shows promising potential as a future fastening system for load-carrying laminated glass plates....

  14. MACMA: a Virtual Lab for Plate Tectonics

    Science.gov (United States)

    Grigne, C.; Combes, M.; Tisseau, C.

    2013-12-01

    MACMA (Multi-Agent Convective MAntle) is a tool developed to simulate evolutive plate tectonics and mantle convection in a 2-D cylindrical geometry (Combes et al., 2012). The model relies mainly on a force balance to compute the velocity of each plate, and on empirical rules to determine how plate boundaries move and evolve. It includes first-order features of plate tectonics: (a) all plates on Earth do not have the same size, (b) subduction zones are asymmetric, (c) plates driven by subducting slabs and upper plates do not exhibit the same velocities, and (d) plate boundaries are mobile, can collide, merge and disappear, and new plate boundaries can be created. The MACMA interface was designed to be user-friendly and a simple use of the simulator can be achieved without any prerequisite knowledge in fluid dynamics, mantle rheology, nor in numerical methods. As a preliminary study, the simulator was used by a few students from bachelor's degree to master's degree levels. An initial configuration for plate tectonics has to be created before starting a simulation: the number and types of plate boundaries (ridge, subduction, passive margins) has to be defined and seafloor ages must be given. A simple but interesting exercise consists in letting students build such an initial configuration: they must analyze a map of tectonic plates, choose a 2-D section and examine carefully a map of seafloor ages. Students mentioned that the exercise made them realize that the 3-D spherical structure of plate tectonics does not translate directly in a simple 2-D section, as opposed to what is usually shown in books. Physical parameters: e.g. mantle viscosity, number of layers to consider in the mantle (upper and lower mantle, possible asthenosphere), initial time and mantle temperature, have to be chosen, and students can use this virtual lab to see how different scenarios emerge when parameters are varied. Very importantly, the direct visualization of the mobility of plate

  15. OPTIMAL DESIGN OF QUADRATIC SANDWICH PLATE

    Directory of Open Access Journals (Sweden)

    TIMAR Dr. Imre

    2016-05-01

    Full Text Available In this paper, we show the optimal design of the three-layered sandwich plates. The objective function contains the material and fabrication costs. The design constraints are the maximal stresses, the deflection of plates and damping of vibrations. The unknown is the thickness of the filling foam. By the mathematical method, we define the minima of the cost function and the optimal thickness of the filling layer of foam. The active constraint is the deflection, so we calculate of the costs of the sandwich plate with the homogeneous plate.

  16. Pulse reversal plating of nickel alloys

    DEFF Research Database (Denmark)

    Tang, Peter Torben

    2007-01-01

    Pulse plating has previously been reported to improve the properties of nickel and nickel alloy deposits. Typically, focus has been on properties such as grain size, hardness and smoothness. When pulse plating is to be utilised for microtechnologies such as microelectromechanical systems (MEMS......), internal stress and material distribution are even more important. With baths based upon nickel chloride, and nickel and cobalt chlorides, pulse reversal plating of both pure nickel and nickel-cobalt alloys has been used to fabricate tools for microinjection moulding. Pulse reversal plating of ternary soft...... magnetic alloys, comprising 45-65%Co, 15-35%Fe and 15-35%Ni, is also reported....

  17. Bone densitometry in pediatric patients treated with pamidronate

    Energy Technology Data Exchange (ETDEWEB)

    Grissom, Leslie E.; Kecskemethy, Heidi H.; Harcke, H.Theodore [Alfred I. duPont Hospital for Children, Nemours Children' s Clinic, Department of Medical Imaging, P.O. Box 269, Wilmington, DE (United States); Bachrach, Steven J. [Alfred I. duPont Hospital for Children, Nemours Children' s Clinic, Division of General Pediatrics, P.O. Box 269, Wilmington, DE (United States); McKay, Charles [Alfred I. duPont Hospital for Children, Nemours Children' s Clinic, Division of Nephrology, P.O. Box 269, Wilmington, DE (United States)

    2005-05-01

    To determine the effect of intravenous pamidronate on the bone mineral density of children with osteogenesis imperfecta and spastic quadriplegic cerebral palsy. Charts of 38 children with osteogenesis imperfecta (n=20) and spastic quadriplegic cerebral palsy (n=18) treated with pamidronate were retrospectively reviewed. Patients were selected for treatment because of prior fracture and/or abnormally low bone mineral density. All received intravenous pamidronate at two-month to eight-month intervals and were periodically examined using dual energy X-ray absorptiometry. All patients had abnormally low bone mineral density prior to treatment. Lumbar spine bone mineral density and z-scores showed serial improvement in 31 of 32 patients. Spine bone mineral density increased 78{+-}38.1% in OI and 47.4{+-}39.0% in children with cerebral palsy. The area of greatest lateral distal femur bone mineral density improvement was in the metaphysis adjacent to the growth plate, with a 96{+-}87.8% improvement in the osteogenesis imperfecta group and 65.7{+-}55.2% improvement in the cerebral palsy group. Increases in bone mineral density exceeded that expected for age-specific growth. This was demonstrated by improvement in both spine and femur z-scores for both groups. No children with spastic quadriplegic cerebral palsy experienced fractures after the first week of treatment, whereas patients with osteogenesis imperfecta continued to have fractures but at a decreased rate. (orig.)

  18. Bone densitometry in pediatric patients treated with pamidronate

    International Nuclear Information System (INIS)

    Grissom, Leslie E.; Kecskemethy, Heidi H.; Harcke, H.Theodore; Bachrach, Steven J.; McKay, Charles

    2005-01-01

    To determine the effect of intravenous pamidronate on the bone mineral density of children with osteogenesis imperfecta and spastic quadriplegic cerebral palsy. Charts of 38 children with osteogenesis imperfecta (n=20) and spastic quadriplegic cerebral palsy (n=18) treated with pamidronate were retrospectively reviewed. Patients were selected for treatment because of prior fracture and/or abnormally low bone mineral density. All received intravenous pamidronate at two-month to eight-month intervals and were periodically examined using dual energy X-ray absorptiometry. All patients had abnormally low bone mineral density prior to treatment. Lumbar spine bone mineral density and z-scores showed serial improvement in 31 of 32 patients. Spine bone mineral density increased 78±38.1% in OI and 47.4±39.0% in children with cerebral palsy. The area of greatest lateral distal femur bone mineral density improvement was in the metaphysis adjacent to the growth plate, with a 96±87.8% improvement in the osteogenesis imperfecta group and 65.7±55.2% improvement in the cerebral palsy group. Increases in bone mineral density exceeded that expected for age-specific growth. This was demonstrated by improvement in both spine and femur z-scores for both groups. No children with spastic quadriplegic cerebral palsy experienced fractures after the first week of treatment, whereas patients with osteogenesis imperfecta continued to have fractures but at a decreased rate. (orig.)

  19. Col11a1 Regulates Bone Microarchitecture during Embryonic Development

    Directory of Open Access Journals (Sweden)

    Anthony Hafez

    2015-12-01

    Full Text Available Collagen XI alpha 1 (Col11a1 is an extracellular matrix molecule required for embryonic development with a role in both nucleating the formation of fibrils and regulating the diameter of heterotypic fibrils during collagen fibrillar assembly. Although found in many different tissues throughout the vertebrate body, Col11a1 plays an essential role in endochondral ossification. To further understand the function of Col11a1 in the process of bone formation, we compared skeletal mineralization in wild-type (WT mice and Col11a1-deficient mice using X-ray microtomography (micro-CT and histology. Changes in trabecular bone microstructure were observed and are presented here. Additionally, changes to the periosteal bone collar of developing long bones were observed and resulted in an increase in thickness in the case of Col11a1-deficient mice compared to WT littermates. Vertebral bodies were incompletely formed in the absence of Col11a1. The data demonstrate that Col11a1 depletion results in alteration to newly-formed bone and is consistent with a role for Col11a1 in mineralization. These findings indicate that expression of Col11a1 in the growth plate and perichondrium is essential for trabecular bone and bone collar formation during endochondral ossification. The observed changes to mineralized tissues further define the function of Col11a1.

  20. Recapping hemilaminoplasty for spinal surgical disorders using ultrasonic bone curette.

    Science.gov (United States)

    Matsuoka, Hidenori; Itoh, Yasunobu; Numazawa, Shinichi; Tomii, Masato; Watanabe, Kazuo; Hirano, Yoshitaka; Nakagawa, Hiroshi

    2012-01-01

    The authors present a novel method of the recapping hemilaminoplasty in a retrospective study of patients with spinal surgical disorders. This report describes the surgical technique and the results of hemilaminoplasty using an ultrasonic bone curette. The aim of this study was to examine the safety and effectiveness of the hemilaminoplasty technique with ultrasonic bone curette. Between April 2003 and July 2011, 33 patients with various spinal diseases (17 spinal tumors, 5 dural arteriovenous fistulas, 3 syringomyelia, 2 sacral perineural cysts, and 2 arachnoid cysts) were treated microsurgically by using an ultrasonic bone curette with scalpel blade and lightweight handpiece. The ultrasonic bone curette was used for division of lamina. After resection of the lesion, the excised lamina was replaced exactly in situ to its original anatomic position with a titanium plate and screw. Additional fusion technique was not required and the device was easy to handle. All patients were observed both neurologically and radiologically by dynamic plain radiographs and computed tomography (CT) scan. The operation was performed successfully and there were no instrument-related complications such as dural laceration, nerve root injury, and vessels injury. The mean number of resected and restored lamina was 1.7. CT confirmed primary bone fusion in all patients by 12 months after surgery. The ultrasonic bone curette is a useful instrument for recapping hemilaminoplasty in various spinal surgeries. This method allows anatomical reconstruction of the excised bone to preserve the posterior surrounding tissues.

  1. The ultrastructure of bone and its relevance to mechanical properties

    Science.gov (United States)

    Schwarcz, Henry P.; Abueidda, Diab; Jasiuk, Iwona

    2017-09-01

    Bone is a biologically generated composite material comprised of two major structural components: crystals of apatite and collagen fibrils. Computational analysis of the mechanical properties of bone must make assumptions about the geometric and topological relationships between these components. Recent transmission electron microscope (TEM) studies of samples of bone prepared using ion milling methods have revealed important previously unrecognized features in the ultrastructure of bone. These studies show that most of the mineral in bone lies outside the fibrils and is organized into elongated plates 5 nanometers (nm) thick, 80 nm wide and hundreds of nm long. These so-called mineral lamellae (MLs) are mosaics of single 5 nm-thick, 20 - 50 nm wide crystals bonded at their edges. MLs occur either stacked around the 50 nm-diameter collagen fibrils, or in parallel stacks of 5 or more MLs situated between fibrils. About 20% of mineral is in gap zones within the fibrils. MLs are apparently glued together into mechanically coherent stacks which break across the stack rather than delaminating. ML stacks should behave as cohesive units during bone deformation. Finite element computations of mechanical properties of bone show that the model including such features generates greater stiffness and strength than are obtained using conventional models in which most of the mineral, in the form of isolated crystals, is situated inside collagen fibrils.

  2. TEXTILE IMPACT PLATES FOR NANOPARTICLES

    Directory of Open Access Journals (Sweden)

    VISILEANU Emilia

    2017-05-01

    Full Text Available The paper presents textile materials with destination impact plates, having different surface architectures and active treatments for functionalization, with influence upon the aging process of nano-Ag and nano-CeO2. The woven and knitted samples from 100% cotton, cotton/PES blend and 100% PES were treated by impregnation on the laboratory padding machine, drying and condensing on the machine for drying-condensing-heat setting, with the following recipes: 50g/l RUCOSTAR EEE6+20 ml 5% nano-Ag dispersion, or 10% nano-CeO2 in ethylene glycol, respectively water and 0,5ml acetic acid 60% for products from 100% cotton and PES/cotton and 50g/l NUVA N 2114 liquid with the same percent of nanoparticles but with 1 ml/l acetic acid 60%, in case of 100% PES samples. The samples were treated in 2 steps – hydrophobic/ oleo phobic in the first stage and hydrophobic/ oleo phobic/ functionalization with nano-Ag and nano-CeO2 in the second stage. The complex characterization of both type of materials : hydrophobic and oleo phobic properties, color change, whitening degree, DCS, FT-IR, SEM and microbiology, evidenced through the obtained results the justness of the selection for: the raw materials (100% cotton, cotton/PES, 100% PES, the weave (plain, twill, rib, pique, the fabric tightness and fabric cover etc. These data allowed the elaboration of textile material’s specifications for impact plates.

  3. Synchrotron μCT Imaging of Bone, Titanium implants and Bone Substitutes -a Systematic Review of the Literature

    DEFF Research Database (Denmark)

    Neldam, Camilla Albeck; Pinholt, Else Marie

    2014-01-01

    Today x-ray micro computer tomography (μCT) imaging is used to investigate bone microarchitecture. μCT imaging is obtained by polychromatic x-ray beams, resulting in images with beam hardening artifacts, resolution levels at 10 μm, geometrical blurring, and lack of contrasts. When μCT is coupled...... examinations, SRμCT is considered as a gold standard to image trabecular bone microarchitecture since it is possible in a 3D manner to visualize fine structural elements within mineralized tissue such as osteon boundaries, rods and plates structures, cement lines, and differences in mineralization...

  4. Biomaterials and bone mechanotransduction

    Science.gov (United States)

    Sikavitsas, V. I.; Temenoff, J. S.; Mikos, A. G.; McIntire, L. V. (Principal Investigator)

    2001-01-01

    Bone is an extremely complex tissue that provides many essential functions in the body. Bone tissue engineering holds great promise in providing strategies that will result in complete regeneration of bone and restoration of its function. Currently, such strategies include the transplantation of highly porous scaffolds seeded with cells. Prior to transplantation the seeded cells are cultured in vitro in order for the cells to proliferate, differentiate and generate extracellular matrix. Factors that can affect cellular function include the cell-biomaterial interaction, as well as the biochemical and the mechanical environment. To optimize culture conditions, good understanding of these parameters is necessary. The new developments in bone biology, bone cell mechanotransduction, and cell-surface interactions are reviewed here to demonstrate that bone mechanotransduction is strongly influenced by the biomaterial properties.

  5. Biophotonics and Bone Biology

    Science.gov (United States)

    Zimmerli, Gregory; Fischer, David; Asipauskas, Marius; Chauhan, Chirag; Compitello, Nicole; Burke, Jamie; Tate, Melissa Knothe

    2004-01-01

    One of the more-serious side effects of extended space flight is an accelerated bone loss [Bioastronautics Critical Path Roadmap, http://research.hq.nasa.gov/code_u/bcpr/index.cfm]. Rates of bone loss are highest in the weight-bearing bones of the hip and spine regions, and the average rate of bone loss as measured by bone mineral density measurements is around 1.2% per month for persons in a microgravity environment. It shows that an extrapolation of the microgravity induced bone loss rates to longer time scales, such as a 2.5 year round-trip to Mars (6 months out at 0 g, 1.5 year stay on Mars at 0.38 g, 6 months back at 0 g), could severely compromise the skeletal system of such a person.

  6. Complications associated with locking plate of proximal humerus fractures

    Directory of Open Access Journals (Sweden)

    Venkat Kavuri

    2018-01-01

    Full Text Available Proximal humerus fractures constitute a significant percentage of fragility fractures. The growing use of locking plate has helped treat this problem, but at the same time has brought about complications. Past systematic reviews have documented these complications, however a large number of recent studies have been published since, reporting their own complication rates with different techniques. This study reviews the current complications associated with locking plate of proximal humerus fractures as well as methods to reduce them. A systematic review, following the PRISMA guidelines, was conducted in November 2013 and repeated in March 2015, using PubMed, Scopus, and Cochrane databases, to evaluate locking plate fixation (and complications of traumatic proximal humerus fractures. Inclusion criteria included adults (>18 years, minimum of 12-month postoperative followup, articles within the last 5 years, and studies with >10 participants. Exclusion criteria included pathologic fractures, cadaveric studies, and nonhuman subjects. Eligible studies were graded using a quality scoring system. Articles with a minimum of 7/10 score were included and assessed regarding their level of evidence per the Journal of Bone and Joint Surgery and Centre for Evidence-Based Medicine guidelines. The initial query identified 51,206 articles from multiple databases. These records were thoroughly screened and resulted in 57 articles, consisting of seven Level 1, three Level 2, 10 Level 3, and 37 Level 4 studies, totaling 3422 proximal humerus fractures treated with locking plates. Intraarticular screw penetration was the most reported complication (9.5%, followed by varus collapse (6.8%, subacromial impingement (5.0%, avascular necrosis (4.6%, adhesive capsulitis (4.0%, nonunion (1.5%, and deep infection (1.4%. Reoperation occurred at a rate of 13.8%. Collapse at the fracture site contributed to a majority of the implant-related complications, which in turn were the

  7. PTH Signaling During Exercise Contributes to Bone Adaptation†

    Science.gov (United States)

    Gardinier, Joseph D.; Mohamed, Fatma; Kohn, David H.

    2016-01-01

    Improving the structural integrity of bone reduces fracture risk and development of osteoporosis later in life. Exercise can increase the mechanical properties of bone, and this increase is often attributed to the dynamic loading created during exercise. However, the increase in systemic PTH levels during exercise gives reason to hypothesize that PTH signaling also regulates bone adaptation in response to exercise. Therefore, the first aim of this study was to establish the impact PTH signaling has on bone adaptation during exercise by inhibiting PTH signaling with PTH(7-34) and the second aim was to determine if increasing PTH levels during exercise with PTH(1-34) can augment bone adaptation. Thirty minutes after a single bout of running on a treadmill, mice exhibited a two-fold increase in systemic PTH levels. Under the same exercise regimen, the influence of PTH signaling on bone adaptation during exercise was then evaluated in mice after 21 consecutive days of exercise and treatment with PTH(7-34), PTH(1-34), or vehicle. Exercise alone caused a significant increase in trabecular bone volume with adaptation to a more plate-like structure, which was inhibited with PTH(7-34) during exercise. Changes in structural and tissue-level mechanical properties during exercise occurred in the absence of significant changes to cortical bone geometry. Inhibition of PTH signaling during exercise attenuated the changes in structural-level mechanical properties, but not tissue-level properties. Enhanced PTH signaling during exercise with PTH(1-34) increased trabecular and cortical bone volume, but had little effect on the structural and tissue-level mechanical properties compared to exercise alone. Our study is the first to demonstrate that bone adaptation during exercise is not only a function of the dynamic loading, but also PTH release, and that PTH signaling contributes differently at the structural and tissue-levels. PMID:25529455

  8. Isolated oestrogen deficiency in male 30-year-old: persistent growth plates with severe osteopenia

    International Nuclear Information System (INIS)

    Smith, T.; Roberts, J.; Howman-Giles, R.; Cowell, C.; Jeremy, R.

    2000-01-01

    Full text: A 31-year-old male presented with right rib pain and generalised skeletal symptoms. He has a past history of multiple fractures following trauma. No history of childhood fractures. Asthma (No steroids). A product of a consanguineous marriage, he has one child aged 7. Examination showed 178.6cm male with normal sexual characteristics. No abnormality detected apart from tenderness over right ribs. Bone scan showed active growth plates and right and left rib fractures. X-rays demonstrated a bone age of 15 1/2 - 16 yrs and a compression fracture of L2. His bone mineral density is severely reduced. Metabolic investigations revealed Testosterone 27.4 nmol (N 11-35), oestradiol < 70 pmol/L, ultrasensitive assay 14 and 17 pmol/L (consistent with 8-year-old male), LH N, FSH N, 46 XY Karyotype. Alkaline phosphatase. 148 (N<120), Normal glucose tolerance test. This patient illustrates a very rare condition of oestrogen deficiency in a male, probably due to aromatase deficiency. This enzyme converts testosterone to oestradiol. It illustrates the role of oestrogen in fusing growth plates and maintaining bone mass in males with otherwise normal androgen levels. A similar clinical picture can result from an oestrogen receptor abnormality. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  9. Chemotherapy decreases epiphyseal strength and increases bone fracture risk.

    Science.gov (United States)

    Van Leeuwen, Barbara L; Verkerke, Gerard J; Hartel, Rene M; Sluiter, Willem J; Kamps, Willem A; Jansen, Henk W B; Hoekstra, Harald J

    2003-08-01

    To establish the effect of three frequently used chemotherapeutic agents in childhood cancer on the skeleton, growing male Wistar rats were studied. Treatment with doxorubicin, methotrexate, and cisplatin reduces the proximal tibial growth plate shear strength because of a decreased surface area and maximum shear stress. After treatment the bone fracture risk of the tibia and femur is increased because of decreased bending resistance. Doxorubicin and cisplatin reduce the maximum shear stress of the proximal tibial growth plate, none of the chemotherapeutic agents inhibit bone mineralization. These effects are caused by treatment-induced malnutrition and the accompanying weight reduction and a direct effect of the chemotherapeutic agents on the skeleton. The current study confirmed the importance of preventing malnutrition during chemotherapeutic treatment in view of possible skeletal complications. During followup of children treated with chemotherapy, attention should be given to signs and symptoms suggestive of such complications.

  10. Application of a Brittle Damage Model to Normal Plate-on-Plate Impact

    National Research Council Canada - National Science Library

    Raftenberg, Martin N

    2005-01-01

    A brittle damage model presented by Grinfeld and Wright of the U.S. Army Research Laboratory was implemented in the LS-DYNA finite element code and applied to the simulation of normal plate-on-plate impact...

  11. Surgical treatment of intraarticular fractures of the calcaneus: comparison between flat plate and calcaneal plate

    Directory of Open Access Journals (Sweden)

    Luiz Carlos Almeida da Silva

    Full Text Available ABSTRACT OBJECTIVE: To evaluate the clinical results of surgical treatment of intraarticular fractures of the calcaneus, comparing the use of calcaneal plate and flat plate. METHODS: This was a retrospective study assessing the postoperative results of 25 patients between 2013 and 2015. Patients undergoing surgical treatment of intraarticular fractures of the calcaneus without concomitant surgical lesions were included. Patients who did not complete appropriate follow-up after surgery were excluded from the study. RESULTS: The unavailability of calcaneal plates at resource-limited settings, associated with the availability and lower cost of flat plates, may have been a confounding factor in the present study. However, there was no statistical difference between the outcomes of fractures treated with calcaneal plates or flat plates. CONCLUSION: Statistical inference shows that, when calcaneal plates are not available, it is possible to use flat plates with similar clinical outcomes.

  12. The petrous bone

    DEFF Research Database (Denmark)

    Jørkov, Marie Louise Schjellerup; Heinemeier, Jan; Lynnerup, Niels

    2009-01-01

    Intraskeletal variation in the composition of carbon (delta(13)C) and nitrogen (delta(15)N) stable isotopes measured in collagen is tested from various human bones and dentine. Samples were taken from the femur, rib, and petrous part of the temporal bone from well-preserved skeletons of both adul...... of this study it is believed the petrous bone may be a new useful bone element and a supplement or a proxy for teeth in the analysis of early dietary patterns as it may reflect diet in fetal stages and early years of life....

  13. Toxicokinetics of bone lead.

    OpenAIRE

    Rabinowitz, M B

    1991-01-01

    This article discusses bone as a source of lead to the rest of the body and as a record of past lead exposure. Bone lead levels generally increase with age at rates dependent on the skeletal site and lead exposure. After occupational exposure, the slow decline in blood lead, a 5- to 19-year half-life, reflects the long skeletal half-life. Repeated measurements of bone lead demonstrate the slow elimination of lead from bone. Stable isotope ratios have revealed many details of skeletal uptake a...

  14. Hypercalciuric Bone Disease

    Science.gov (United States)

    Favus, Murray J.

    2008-09-01

    Hypercalciuria plays an important causal role in many patients with calcium oxalate (CaOx) stones. The source of the hypercalciuria includes increased intestinal Ca absorption and decreased renal tubule Ca reabsorption. In CaOx stone formers with idiopathic hypercalciuria (IH), Ca metabolic balance studies have revealed negative Ca balance and persistent hypercalciuria in the fasting state and during low dietary Ca intake. Bone resorption may also contribute to the high urine Ca excretion and increase the risk of bone loss. Indeed, low bone mass by DEXA scanning has been discovered in many IH patients. Thiazide diuretic agents reduce urine Ca excretion and may increase bone mineral density (BMD), thereby reducing fracture risk. Dietary Ca restriction that has been used unsuccessfully in the treatment of CaOx nephrolithiasis in the past may enhance negative Ca balance and accelerate bone loss. DEXA scans may demonstrate low BMD at the spine, hip, or forearm, with no predictable pattern. The unique pattern of bone histologic changes in IH differs from other causes of low DEXA bone density including postmenopausal osteoporosis, male hypogonadal osteoporosis, and glucocorticoid-induced osteoporosis. Hypercalciuria appears to play an important pathologic role in the development of low bone mass, and therefore correction of urine Ca losses should be a primary target for treatment of the bone disease accompanying IH.

  15. FUNCTIONAL OUTCOME OF PROXIMAL HUMERUS FRACTURES TREATED WITH LOCKING PLATES

    Directory of Open Access Journals (Sweden)

    Lokesh

    2016-05-01

    Full Text Available INTRODUCTION For more displaced fractures and osteopenic bone, techniques of internal fixation, which emphasise less disruptive soft tissue dissection, and minimal fixation with wire and non-absorbable sutures have been successful with a low complication rate. Even AO type buttress plates are being used, but they require more soft tissue dissection and may lead to infection. Management of these fractures is associated with some morbidity and undesirable sequelae. They include complications like avascular necrosis, malunion, non-union, infection, neurovascular injury, loss of motion of shoulder from adhesive capsulitis, chronic oedema, elbow stiffness and atrophy of the soft tissues of the immobilised limb causing significant disability during healing and afterwards. The purpose of this study is to evaluate the functional outcome of the surgical management of fresh displaced three- and four-part proximal humerus fractures with locking plate system. MATERIAL AND METHODS The present study was carried out from August 2012 to December 2014 at Orthopaedic Department in Bangalore Medical College and Hospital. During this period, 25 patients of proximal humerus fractures were treated with locking plates. All patients were followed up for every 4 weeks. Local examination of the affected shoulder for tenderness, instability, deformity and shoulder movements were assessed. X-rays were taken at each visit to know about progressive fracture union and implant position. Rehabilitation of the affected extremity was done according to the stage of fracture union and time duration from surgery. Patients were followed up till radiological union. RESULTS The present study consists of 25 patients of fresh three- and four-part fractures of proximal humerus which were treated surgically with locking plates from August 2012 to December 2014. All the patients were available for follow-up and they were followed every month for first 3 months then once in 3 months. In this

  16. Traumatic bone cyst, idiopathic origin

    African Journals Online (AJOL)

    GB

    BACKGROUND: Traumatic bone cyst (TBC) is an uncommon non-epithelial lined cavity of the jaws. Traumatic bone cysts have been reported in the literature under a variety of names: solitary bone cyst, haemorrhagic bone cyst, extravasation cyst and simple bone cyst. The multitude of names applied to this lesion implies ...

  17. Effects of Phlomis umbrosa Root on Longitudinal Bone Growth Rate in Adolescent Female Rats

    Directory of Open Access Journals (Sweden)

    Donghun Lee

    2016-04-01

    Full Text Available This study aimed to investigate the effects of Phlomis umbrosa root on bone growth and growth mediators in rats. Female adolescent rats were administered P. umbrosa extract, recombinant human growth hormone or vehicle for 10 days. Tetracycline was injected intraperitoneally to produce a glowing fluorescence band on the newly formed bone on day 8, and 5-bromo-2′-deoxyuridine was injected to label proliferating chondrocytes on days 8–10. To assess possible endocrine or autocrine/paracrine mechanisms, we evaluated insulin-like growth factor-1 (IGF-1, insulin-like growth factor binding protein-3 (IGFBP-3 or bone morphogenetic protein-2 (BMP-2 in response to P. umbrosa administration in either growth plate or serum. Oral administration of P. umbrosa significantly increased longitudinal bone growth rate, height of hypertrophic zone and chondrocyte proliferation of the proximal tibial growth plate. P. umbrosa also increased serum IGFBP-3 levels and upregulated the expressions of IGF-1 and BMP-2 in growth plate. In conclusion, P. umbrosa increases longitudinal bone growth rate by stimulating proliferation and hypertrophy of chondrocyte with the increment of circulating IGFBP-3. Regarding the immunohistochemical study, the effect of P. umbrosa may also be attributable to upregulation of local IGF-1 and BMP-2 expressions in the growth plate, which can be considered as a GH dependent autocrine/paracrine pathway.

  18. A new technique for insertion of barrel plate over dy-namic hip/compression lag screw: a case report

    Directory of Open Access Journals (Sweden)

    Naranje Sameer

    2012-08-01

    Full Text Available 【Abstract】Dynamic hip/compression screw (DHS/ DCS is one of the most commonly performed surgeries in orthopaedic practice. Sliding barrel plate over the DHS/DCS lag screw is one of the very crucial and at times uncomfor-table and time consuming steps of DHS/DCS surgery espe-cially when it comes to inexperienced surgeons and residents. Also in developing countries where not all stan-dard instrumentation is always available, this crucial step becomes more time consuming. Here we present a case re-port of 58-year-old male patient with intertrochanteric fracture, in which we used a new device for insertion of barrel plate over DHS/DCS lag screw and found that a small DHS/DCS lag screw extension (sliding jig of barrel plate can be very helpful to slide barrel plate over the DHS/DCS lag screw. Key words: Bone screws; Intertrochanteric fracture; Femoral fracture

  19. CT evaluation of sigmoid plate dehiscence causing pulsatile tinnitus

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Pengfei; Lv, Han; Dong, Cheng; Wang, Zhenchang [Capital Medical University, Department of Radiology, Beijing Friendship Hospital, Beijing (China); Niu, Yantao; Xian, Junfang [Capital Medical University, Department of Radiology, Beijing Tongren Hospital, Beijing (China)

    2016-01-15

    To evaluate the characteristics of sigmoid plate dehiscence (SPD) causing pulsatile tinnitus (PT) on CT arteriography and venography (CTA + V). Thirty PT patients treated successfully with SPD reconstruction were enrolled. Sixty asymptomatic patients were matched. The location, extent, number of SPD cases and concomitant signs, including venous outflow dominance, transverse sinus stenosis, high jugular bulb, temporal bone pneumatization, height of pituitary gland and pituitary fossa, abnormal mastoid emissary vein, were detected and compared using CTA + V. More than one SPD was found on the symptomatic side in 13/30 PT patients (43.3 %). The upper segment of the sigmoid plate was involved in 29/44 SPDs in the vertical direction (65.9 %); the lateral wall was involved in 38/44 SPDs in the horizontal direction (86.4 %). Singular SPD was detected in 3/60 asymptomatic patients (1.67 ± 0.35 mm{sup 2}), less so in PT patients (7.97 ± 5.17 mm{sup 2}). Compared with the control group, ipsilateral venous outflow dominance, high jugular bulb and bilateral transverse sinus stenosis were more common in the PT group, together with deeper pituitary fossa and flatter pituitary glands. SPD causing PT has characteristic CT findings. It may be generated by vascular or intracranial pressure abnormalities and act as a common key to triggering PT's perception. (orig.)

  20. CT evaluation of sigmoid plate dehiscence causing pulsatile tinnitus

    International Nuclear Information System (INIS)

    Zhao, Pengfei; Lv, Han; Dong, Cheng; Wang, Zhenchang; Niu, Yantao; Xian, Junfang

    2016-01-01

    To evaluate the characteristics of sigmoid plate dehiscence (SPD) causing pulsatile tinnitus (PT) on CT arteriography and venography (CTA + V). Thirty PT patients treated successfully with SPD reconstruction were enrolled. Sixty asymptomatic patients were matched. The location, extent, number of SPD cases and concomitant signs, including venous outflow dominance, transverse sinus stenosis, high jugular bulb, temporal bone pneumatization, height of pituitary gland and pituitary fossa, abnormal mastoid emissary vein, were detected and compared using CTA + V. More than one SPD was found on the symptomatic side in 13/30 PT patients (43.3 %). The upper segment of the sigmoid plate was involved in 29/44 SPDs in the vertical direction (65.9 %); the lateral wall was involved in 38/44 SPDs in the horizontal direction (86.4 %). Singular SPD was detected in 3/60 asymptomatic patients (1.67 ± 0.35 mm 2 ), less so in PT patients (7.97 ± 5.17 mm 2 ). Compared with the control group, ipsilateral venous outflow dominance, high jugular bulb and bilateral transverse sinus stenosis were more common in the PT group, together with deeper pituitary fossa and flatter pituitary glands. SPD causing PT has characteristic CT findings. It may be generated by vascular or intracranial pressure abnormalities and act as a common key to triggering PT's perception. (orig.)

  1. Antibacterial titanium plate deposited by silver nanoparticles exhibits cell compatibility

    Directory of Open Access Journals (Sweden)

    Juan Liao

    2010-05-01

    Full Text Available Juan Liao1, Mo Anchun1,2, Zhimin Zhu3, Yuan Quan11State Key Laboratory of Oral Diseases, Sichuan University, Chengdu, PR China; 2Department of Dental Implant, 3Department of Prosthodontics; West China Stomatology Hospital, Sichuan University, Chengdu, PR ChinaAbstract: Microbial colonization and biofilm formation on the surface of implant devices may cause peri-implantitis and lead to bone loss. The aim of this study was to develop a novel antibacterial titanium implant surface and to test its biological performance. In a previous study, we demonstrated that titanium plates deposited by nanosilver acquired antibacterial activity to Staphylococcus aureus and Escherichia coli. While antibacterial activity is important, biomaterial surfaces should be modified to achieve excellent cell compatibility as well. In the present study, using the MTT assay, fluorescence microscopy, and scanning electron microscopy, we assessed cell viability, cytoskeletal architecture and cell attachment, respectively, on our silver nanoparticle-modified titanium (Ti-nAg plate. The results demonstrate that the Ti-nAg do not show any cytotoxicity to the human gingival fibroblasts. Our data indicate that Ti-nAg is a novel material with both good antibacterial properties and uncompromised cytocompatibility, which can be used as an implanted biomaterial.Keywords: nanosilver, titanium, antibacterial activity, cytocompatibility

  2. Histology of Epiphyseal Plate of Adolescent Rat Stimulated by Laserpuncture

    Science.gov (United States)

    Handayani, Selfi; Ramelan, Ari H.; Purwanto, Bambang; Saputra, Koosnadi; Tamtomo, Didik G.

    2017-11-01

    Epiphyseal plate was used for determining longitudinal bone growth. Laserpuncture was believed to stimulate height growth. We used 40 male Wistar rats which aged three weeks old and weighed more than 40 g as subjects. They randomly divided into group A or B and each group evenly divided into four subgroups which were a negative control and others applied with laser on GV20, ST 36 or combination of GV 20+ST 36 respectively. These acupoints were then stimulated using the laser. After treatment, mice were sacrificed, then tibias were taken for histology preparation processes. By light microscope, epiphyseal plate (EP) height (µm) and chondrocytes hypertrophy (CH) height were measured at six equidistant points, and the values were averaged to obtain a final result for each section. Collected data were analyzed using ANOVA test, and the significant value was set up p< 0.05. The mean of EC and CH were lower than control, but mean of ratio EP/CH were higher than control. However, ANOVA showed that there did not differ significantly (p=0.36).

  3. Programmed administration of parathyroid hormone increases bone formation and reduces bone loss in hindlimb-unloaded ovariectomized rats

    Science.gov (United States)

    Turner, R. T.; Evans, G. L.; Cavolina, J. M.; Halloran, B.; Morey-Holton, E.

    1998-01-01

    Gonadal insufficiency and reduced mechanical usage are two important risk factors for osteoporosis. The beneficial effects of PTH therapy to reverse the estrogen deficiency-induced bone loss in the laboratory rat are well known, but the influence of mechanical usage in this response has not been established. In this study, the effects of programed administration of PTH on cancellous bone volume and turnover at the proximal tibial metaphysis were determined in hindlimb-unloaded, ovariectomized (OVX), 3-month-old Sprague-Dawley rats. PTH was administered to weight-bearing and hindlimb-unloaded OVX rats with osmotic pumps programed to deliver 20 microg human PTH (approximately 80 microg/kg x day) during a daily 1-h infusion for 7 days. Compared with sham-operated rats, OVX increased longitudinal and radial bone growth, increased indexes of cancellous bone turnover, and resulted in net resorption of cancellous bone. Hindlimb unloading of OVX rats decreased longitudinal and radial bone growth, decreased osteoblast number, increased osteoclast number, and resulted in a further decrease in cancellous bone volume compared with those in weight-bearing OVX rats. Programed administration of PTH had no effect on either radial or longitudinal bone growth in weight-bearing and hindlimb-unloaded OVX rats. PTH treatment had dramatic effects on selected cancellous bone measurements; PTH maintained cancellous bone volume in OVX weight-bearing rats and greatly reduced cancellous bone loss in OVX hindlimb-unloaded rats. In the latter animals, PTH treatment prevented the hindlimb unloading-induced reduction in trabecular thickness, but the hormone was ineffective in preventing either the increase in osteoclast number or the loss of trabecular plates. Importantly, PTH treatment increased the retention of a baseline flurochrome label, osteoblast number, and bone formation in the proximal tibial metaphysis regardless of the level of mechanical usage. These findings demonstrate that

  4. Comparative analysis of locking plate versus hook plate osteosynthesis of Neer type IIB lateral clavicle fractures.

    Science.gov (United States)

    Erdle, Benjamin; Izadpanah, Kaywan; Jaeger, Martin; Jensen, Patrizia; Konstantinidis, Lukas; Zwingmann, Jörn; Südkamp, Norbert P; Maier, Dirk

    2017-05-01

    Controversy exists on optimal operative treatment of vertically unstable Neer IIB lateral clavicle fractures. Aim of this study was to analyse and compare clinical and radiological results and complications of locking plate osteosynthesis (LPO) versus hook plate osteosynthesis (HPO) with acromioclavicular joint (ACJ) stabilization. The hypothesis was, that HPO would recreate coracoclavicular stability more effectively and potentially lead to a superior outcome. This retrospective, observational cohort study included 32 patients (19 HPO, 13 LPO) with a mean age of 44.1 ± 14.2 years at surgery. The mean follow-up period was 54.2 months (range 25.2-111.4 months). Besides standard radiography, bilateral coracoclavicular distances were assessed by means of preoperative and follow-up stress radiographs after implant removal. Clinical outcome measures included the Constant score (CS), the Oxford shoulder score (OSS), the subjective shoulder value (SSV) and the Taft score (TS). Bone union occurred in all but one patient and proved to occur delayed in five patients (15.6%). Radiographical healing required a mean of 4.2 ± 4.0 months irrespective of the type of osteosynthesis. At follow-up, mean coracoclavicular distance was increased by 34% (±36) without significant differences between both groups. HPO patients obtained a significantly lower TS (HPO: 9.5 ± 1.5 points, LPO: 11.1 ± 1.3 points; p = 0.005). Other mean score values did not differ (CS: 90.1 ± 7.4 points, OSS: 43.2 ± 9.2 points, SSV: 91.1 ± 14.7%). Sixteen patients (50.0%) experienced complications. Overall prevalence of complications was significantly higher in the HPO group (p = 0.014). Both HPO and LPO were equally effective in relation to restoration of vertical stability, overall functional outcome and fracture consolidation in treatment of Neer IIB fractures. Contrary to our hypothesis, HPO was not associated with superior recreation of the coracoclavicular

  5. On the Semantics of Plates from the Shilovka Burial Ground

    Directory of Open Access Journals (Sweden)

    Fonyakova (Chuvilo Natalia A.

    2013-03-01

    Full Text Available Among the finds made on the sites located in the Middle Volga region and Siberia, ivory plaques of high artistic value used to adorn combat saddle pommel are met. They would bear floral ornamentation or depict hunting scenes, reflecting the spiritual world of a nomad warrior. These images are dated widely, but not later than the 7th or 8th centuries. They were drawn with a sharp cutter and blackened down the lines. Of special interest are the bone plates from the Shilovka burial ground site (Uyanovsk oblast with the following images: two dragons in a heraldic posture, deer hunt scenes, horsemen in ambush, fight with a bear, and defense of the fortress. In the author’s opinion, the Shilovka plates depict a dramatic episode in the life of a Turkic warlord, which occurred in the midst of hostilities. During the hunt, a huge bear was unleashed against him. Part of his heavily armed convoy (or suite fled; some soldiers got ambushed (the enemy shot them from armor-piercing bows. Saving his life, the captain knelt and bent his bow, whose string broke at the most inopportune moment. Perhaps he died fighting a bear. One can assume that it was a stratagem of the enemy, which decided the outcome of the war. The symbol of victory on the plates is represented by the dragons, frozen in a heraldic posture, and expressing the basic principle of life characteristic of the nomad warriors in the Early Middle Ages: prosperity and well-being at a price of war and victories. The plaques were placed into the winner’s grave.

  6. The Socket Shield Technique using Bone Trephine: A Case Report

    OpenAIRE

    Haseeb Al Dary; Abeer Al Hadidi

    2015-01-01

    Background: To avoid tissue alterations of the ridge after tooth extraction the socket shield technique was first introduced in 2010 by Hurzeler. It was suggested that instead of extracting the whole tooth, the buccal aspect of the root could be left intact to preserve the buccal plate of bone and prevent post extraction resorption, at the same time an immediate implant is placed; this would lead to an optimal stable esthetic result after the final delivery of the restoration. To extract the ...

  7. Genistein treatment increases bone mass in obese, hyperglycemic mice

    Directory of Open Access Journals (Sweden)

    Michelin RM

    2016-03-01

    Full Text Available Richard M Michelin,1 Layla Al-Nakkash,2 Tom L Broderick,3 Jeffrey H Plochocki4 1Arizona College of Osteopathic Medicine, 2Department of Physiology, 3Laboratory of Diabetes and Exercise Metabolism, Department of Physiology, 4Department of Anatomy, Arizona College of Osteopathic Medicine, Midwestern University, Glendale, AZ, USA Background: Obesity and type 2 diabetes mellitus are associated with elevated risk of limb bone fracture. Incidences of these conditions are on the rise worldwide. Genistein, a phytoestrogen, has been shown by several studies to demonstrate bone-protective properties and may improve bone health in obese type 2 diabetics. Methods: In this study, we test the effects of genistein treatment on limb bone and growth plate cartilage histomorphometry in obese, hyperglycemic ob/ob mice. Six-week-old ob/ob mice were divided into control and genistein-treated groups. Genistein-treated mice were fed a diet containing 600 mg genistein/kg for a period of 4 weeks. Cross-sectional geometric and histomorphometric analyses were conducted on tibias. Results: Genistein-treated mice remained obese and hyperglycemic. However, histomorphometric comparisons show that genistein-treated mice have greater tibial midshaft diameters and ratios of cortical bone to total tissue area than the controls. Genistein-treated mice also exhibit decreased growth plate thickness of the proximal tibia. Conclusion: Our results indicate that genistein treatment affects bone of the tibial midshaft in the ob/ob mouse, independent of improvements in the hyperglycemic state and body weight. Keywords: obesity, hyperglycemia, genistein, ob/ob mice, bone

  8. Radiological findings and clinical results of 102 thrust-plate femoral hip prostheses: a follow-up of 2 to 8 years.

    Science.gov (United States)

    Buergi, Martin L; Stoffel, Karl K; Jacob, Hilaire A C; Bereiter, Heinz H

    2005-01-01

    We report the radiological and clinical outcome of 102 consecutive femoral hip arthroplasty we prospectively followed up in 84 patients using the third generation of the thrust-plate prosthesis with a mean period of follow-up of 58 (range, 26-100) months. Four implants were revised: 2 because of an infection and 2 because of aseptic loosening. The thrust-plate prosthesis, which allows preservation of part of the femoral neck, was used in younger patients, 80% were younger than 60 years. In 95 implants, contact was maintained between thrust plate and underlying bone, and in only 3 instances, without any clinical manifestation, did the bone retract from the thrust plate to the extent that a gap appeared. The extent of radiologically evident bone contact with the flat surface of the thrust plate, as a consequence of the bone remodeling behavior, is described and retrospectively classified. The average Harris hip score increased from 51 points preoperatively to 96 points postoperatively at the last follow-up. Survivorship analysis according to Kaplan-Meier showed a survival rate of 98% after 6 years, with no further losses up to the end of the 8-year follow-up period.

  9. Extraskeletal and intraskeletal new bone formation induced by demineralized bone matrix combined with bone marrow cells

    International Nuclear Information System (INIS)

    Lindholm, T.S.; Nilsson, O.S.; Lindholm, T.C.

    1982-01-01

    Dilutions of fresh autogenous bone marrow cells in combination with allogeneic demineralized cortical bone matrix were tested extraskeletally in rats using roentgenographic, histologic, and 45 Ca techniques. Suspensions of bone marrow cells (especially diluted 1:2 with culture media) combined with demineralized cortical bone seemed to induce significantly more new bone than did demineralized bone, bone marrow, or composite grafts with whole bone marrow, respectively. In a short-term spinal fusion experiment, demineralized cortical bone combined with fresh bone marrow produced new bone and bridged the interspace between the spinous processes faster than other transplantation procedures. The induction of undifferentiated host cells by demineralized bone matrix is further complemented by addition of autogenous, especially slightly diluted, bone marrow cells

  10. THE RESULT OF INTRAMEDULLARY NAILING WITH BONE GRAFTING OF TIBIA'S PATHOLOGIC FRACTURE

    Directory of Open Access Journals (Sweden)

    V. M. Shapovalov

    2010-01-01

    Full Text Available The authors give the clinical case of successful surgical treatment of patient with tibia's pathologic fracture by intramedullary nailing with bone grafting. The disadvantages of such patients' treatment by plaster immobilization and by some invasive methods like vascular autografting by Ilizarov's method and bone plating were also discussed. The obvious benefits of proposed surgical treatment technique of observed patient category are shown.

  11. Complications of appendicular fracture repair in cats and small dogs using locking compression plates.

    Science.gov (United States)

    Vallefuoco, Rosario; Le Pommellet, Helene; Savin, Audrey; Decambron, Adeline; Manassero, Mathieu; Viateau, Véronique; Gauthier, Olivier; Fayolle, Pascal

    2016-01-01

    Our objectives were: 1) to review the complications associated with stabilization of appendicular fractures in cats and small dogs using locking compression plates (LCP), and 2) to identify factors that could influence fixation construct stability. Retrospective clinical study. Medical and radiographic records of cats and small dogs with appendicular fractures treated with LCP were reviewed. Only cases with adequate follow-up to document clinical union and cases for which complications appeared before the clinical union were included. Complications were classified as implant-related complications or other complications. Cases with implant-related complications were compared to cases with non-implant-related complications for differences in signalment (species, age, body weight, multiple fractures), fracture location and type (fractured bone, fracture localization, closed or open fracture), reduction method (open reduction and internal fixation [ORIF] or minimally invasive plate osteosynthesis [MIPO]) and fixation evaluations (implant size, plate-bridging ratio, plate span ratio, working length, plate screw density, number of screws and cortices engaged per plate and per main fragment, ratio between screw and bone diameter at the narrowest aspect of the bone, and presence of ancillary fixation). Seventy-five fractures from 63 cats (64 fractures) and 10 dogs (11 fractures) met the inclusion criteria. Eight humeral, 13 radio-ulnar, 26 femoral, and 28 tibio-fibular fractures were treated. Primary repair of the fracture was performed using 2.0 mm and 2.4 mm LCP in 22 and 53 fractures, respectively. Overall and implant-related complications were encountered in 13 and seven of 75 fractures, respectively. Fixation failure was not significantly associated with any aforementioned factor considered in this study, and in particular, there was no significant difference in the occurrence of fixation failure between fractures stabilized with two, or more than two, bicortical

  12. Buccal bone loss after immediate implantation can be reduced by the flapless approach

    Directory of Open Access Journals (Sweden)

    ARTHUR BELÉM NOVAES JR

    2011-10-01

    Full Text Available Aim: The aim of this study was to evaluate the buccal bone remodeling after immediate implantation with flap or flapless approach. Material and Methods: The mandibular bilateral premolars of 3 dogs were extracted and immediately three implants were placed in both hemi-arches of each dog. Randomly, one hemi-arch was treated with the flapless approach, while in the contra lateral hemi-arch tooth extractions and implant placement were done after mucoperiosteal flap elevation. Non-submerged healing of 12 weeks was provided for both groups. Histomorphometric analysis was done to compare buccal and lingual bone height loss, bone density and bone-to-implant contact in the groups. Fluorescence analysis was performed to investigate the dynamic of bone remodeling in the different groups. Results: There was a significant association between the surgical flap and the extent of bone resorption around immediate implants. The loss of buccal bone height was significantly lower in the flapless group when compared to the flap group (0.98 mm x 2.14 mm, respectively, p<0.05. The coronal and apical buccal bone densities of the flap group were significantly higher when compared to the lingual components, showing anatomical differences between the bone plates. Fluorescence analysis showed no major differences in bone healing between the flap and flapless groups, supporting that the higher loss of buccal bone height is linked to the anatomic characteristics of this plate and to the negative influence of the detachment of the periosteum in immediate implant therapy. Conclusion: The flapless approach for immediate post-extraction implants reduces the buccal bone height loss.

  13. Steel plate reinforcement of orthotropic bridge decks

    NARCIS (Netherlands)

    Teixeira de Freitas, S.

    2012-01-01

    The PhD research is focused on the reinforcement of fatigue cracked orthotropic steel bridge decks (OBD) by adding a second steel plate to the existing deck. The main idea is to stiffen the existing deck plate, which will reduce the stresses at the fatigue sensitive details and extend the fatigue

  14. DOES TUBULARIZED INCISED PLATE URETHROPLASTY FIT

    African Journals Online (AJOL)

    posterior or proximal hypospadias. Patient age ranged from 22 months to 9 years (mean 5.4 years). Twenty-two cases were primary, while. 10 cases were repeat cases after failed onlay procedures with preserved urethral plate. Cases with severe chordee necessitating ex- cision of the urethral plate or with a very thin.

  15. Fresnel diffraction plates are simple and inexpensive

    Science.gov (United States)

    Hoover, R. B.

    1967-01-01

    Fresnel plate demonstrates diffraction phenomena simply and inexpensively. A large number of identical diffracting apertures are made in random orientation on photographic film. When a small source of light is viewed through the plate, the diffraction pattern typical of the diffracting aperture is readily seen.

  16. Plate Tectonic Cycle. K-6 Science Curriculum.

    Science.gov (United States)

    Blueford, J. R.; And Others

    Plate Tectonics Cycle is one of the units of a K-6 unified science curriculum program. The unit consists of four organizing sub-themes: (1) volcanoes (covering formation, distribution, and major volcanic groups); (2) earthquakes (with investigations on wave movements, seismograms and sub-suface earth currents); (3) plate tectonics (providing maps…

  17. Method of nickel-plating large components

    International Nuclear Information System (INIS)

    Wilbuer, K.

    1997-01-01

    The invention concerns a method of nickel-plating components, according to which even large components can be provided with an adequate layer of nickel which is pore- and stress-free and such that water is not lost. According to the invention, the component is heated and, after heating, is pickled, rinsed, scoured, plated in an electrolysis process, and rinsed again. (author)

  18. Improved nickel plating of Inconel X-750

    Science.gov (United States)

    Farmer, M. E.; Feeney, J. E.; Kuster, C. A.

    1969-01-01

    Electroplating technique with acid pickling provides a method of applying nickel plating on Inconel X-750 tubing to serve as a wetting agent during brazing. Low-stress nickel-plating bath contains no organic wetting agents that cause the nickel to blister at high temperatures.

  19. Marangoni flow on an inkjet nozzle plate

    NARCIS (Netherlands)

    de Jong, J.; Reinten, Hans; Wijshoff, H.; Wijshoff, Herman; van den Berg, Marc; Delescen, Koos; van Dongen, Rini; Mugele, Friedrich Gunther; Versluis, Michel; Lohse, Detlef

    2007-01-01

    In piezo inkjet printing, nozzle failures are often caused by an ink layer on the nozzle plate. It is experimentally shown that the ink layer at the nozzle is formed through streamers of ink, emanating from a central ink band on the nozzle plate. The streamers propagate over a wetting nanofilm of

  20. 49 CFR 230.46 - Badge plates.

    Science.gov (United States)

    2010-10-01

    ... TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Gauges § 230.46 Badge plates. A metal badge plate showing the allowed steam pressure shall be attached to the boiler backhead in the cab. If boiler backhead is lagged, the lagging and jacket shall be cut away so...