WorldWideScience

Sample records for body x-ray irradiation

  1. Dosimetry for total body irradiation of rhesus monkeys with 300 kV X- rays

    NARCIS (Netherlands)

    Zoetelief, J.; Wagemaker, G.; Broerse, J.J.

    1998-01-01

    Purpose: To obtain more accurate information on the dose distribution in rhesus monkeys for total body irradiation with orthovoltage X-rays. Materials and methods: Dose measurements were performed with an ionization chamber inside homogeneous cylindrical and rectangular phantoms of various

  2. Beta-glucosidase activity of ER-bodies in Arabidopsis thaliana seedlings under clinorotation and after X-ray irradiation

    Science.gov (United States)

    Romanchuk, Svitlana

    Realization of long-term space flight requires the life support bioregenerative systems, an indispensable component of which are plants as a source of oxygen, water and food. Although it is well known now that plants adopt to spaceflight factors, in particular to microgravity, by changing some their patterns at the cellular, physiological, biochemical and molecular levels, many questions on cause and effect of these changes are still open. In addition, it is necessary to find the plant species which will be the most suited to the conditions in a space craft cabin. Plants of the family Brassicaceae are known to be resistant to a variety of abiotic stresses, including irradiation. Among them there are many cultivated plants with which we encounter every day: cabbage, radish, mustard, rapeseed, etc., and Arabidopsis thaliana - a convenient model object. The family Brassicaceae to be characterized by the presence of ER-bodies in plant cells, which are derivative of granular endoplasmic reticulum. Earlier, an enzyme beta-glucosidase (beta-D-glucoside glucohydrolase; EC 3.2.1.21) with an ER retention signal has been shown to accumulate selectively in such bodies in response to different unfavorable factors. Recently, we reported that formation of ER-bodies in A. thaliana seedling roots is sensitive to the clinorotation and X-ray irradiation, as their quantity and size in creased under the influence of these factors in comparison with control.begin{itemize} Therefore, we determined the beta-glucosidase activity in A. thaliana (line Columbia) seedlings grown in the stationary conditions and under clinorotation (a); and after X-ray irradiation (b): a) 3- and 7-day-old seedlings grown on a slow horizontal clinostat (2rpm); b) 3-day-old seedlings were treated with X-ray radiation dose of 0.5, 1.0, 2.0, 4.0, 6.0, 8.0, 10 and 12 Gray. For the first time, an increase in beta-glucosidase activity, which is the main component of the ER-bodies in A. thaliana seedlings, were found

  3. X-raying with low dose irradiation

    International Nuclear Information System (INIS)

    Malevich, E.E.; Kisel, E.M.; Shpita, I.D.; Lazovsky, A.S.

    2001-01-01

    with higher frequency of a pulsation the share of unproductive radiation is higher. At x-raying controlled by the grid pulses are generated by the x-ray tube with the grid control. The grid, located between the cathode and the anode, passes the electron cloud without the expenses of time for dispersal and attenuation. It gives sharply outlined, rectangular x-ray pulses with homogeneous quality of radiation. Function GC F -x-raying controlled by the grid - enables to receive precisely outlined contours of moving objects: a heart, a gullet, - and also to carry out examination of the children without information loss during simultaneous dose decrease. Besides the image remains precise even during the movement of the electron-optical converter. Owing to radiation parameters adjustment during the examination the effect of the lighted image is eliminated. X-raying devices Easy Diagnose and Diagnose-76 'Philips' are equipped with the system of digital x-ray image processing besides they are completed with the x-ray tube with Grid Controlled Fluoroscopy that allows to carry out pulse x-raying with number of pulses 2, 3, 6 and 12 per a second. So, with 12 pulses per second the irradiation dose in comparison with continuous radiation decreases on 40%. The examinations of a chest, gullet, stomach and thick gut were carried out at the frequency of 12 and 6 pulses per second. In the hospital of the Ministry of Internal Affairs where device Easy Diagnose is established, at examinations of a gastro enteric path (stomach x-raying, irrigoscopy) usually pulse x-raying is used with frequency 12 pulses per second. It allows significantly reduce the beam load on a patient. The calculation of beam loads on a patient was carried out on the basis of exposition dose level at the beam input in the body of a patient (entrance dose). The way is applied for especially exact calculations, as definitions of effective doses on separate organs and all body are difficult. The irradiation dose is in

  4. Study of food intake dynamics in rats following acute whole-body irradiation with X rays

    International Nuclear Information System (INIS)

    Smajda, B.; Ahlers, I.; Datelinka, I.

    1987-01-01

    The effects were studied of whole-body X-irradiation with sublethal (2.39 Gy) and medium lethal (5.74 Gy) doses on food intake by rats. The lower dose caused a temporary decrease in food intake, with a minimum of 63.3% of the control level on the 2nd day after irradiation. The decrease was statistically significant up to the 4th day after irradiation. No substantial changes were observed in the parameters of the circadian rhythm in food intake with the maximum on the 3rd day after irradiation, with only 8% of the initial value. The food intake was reduced until the 9th day after irradiation. The daily thythm of food intake was strongly disturbed during the first three days after irradiation, then restoring gradually and on the 9th day showing the original phasing and shape. The results obtained were in agreement with the assumed neural regulation mechanism of food intake and its circadian rhythm in the rat. (author). 5 figs., 12 refs

  5. Pathomorphological and pathogenetic studies of the radiation syndrome in calfs and heifers after whole-body irradiation with X-rays

    International Nuclear Information System (INIS)

    Johannsen, U.; Koch, E.; Mehlhorn, G.; Panndorf, H.

    1978-01-01

    27 calfs were exposed to whole-body X-ray doses of 170 R and 150 R, respectively. 14 animals which died between the 17th and 27th day after irradiation were examined. The most important pathomorphological findings were: hematopoietic disorders, hemorrhagic diatheses together with pneumonia, liver degeneration, damage to the intestine (only in animals irradiated with 170 R), and malnutrition

  6. Pathomorphological studies of the radiation syndrome in sheep after whole-body irradiation with X-rays

    International Nuclear Information System (INIS)

    Johannsen, U.; Mehlhorn, G.; Koch, F.; Panndorf, H.

    1978-01-01

    Eight one-year-old Merino mutton sheep were irradiated with X-ray doses of 380 R. Five of the animals died between the 16th and 25th day after irradiation and were examined. In organs and tissues a great diversity of pathological changes was observed as for instance hematopoietic disorders, septic processes, hemorrhagic diatheses, and partial epilation

  7. Determination of conversion factors between body doses and relevant radiation quantities for external X-ray and gamma irradiation

    International Nuclear Information System (INIS)

    Kramer, R.

    1979-02-01

    With particular consideration of ICRP-26 conversion factors between body doses and relevant radiation quantities for external X- and gamma radiation were assessed. Determination of these conversion factors included all areas of professional, medical, and environmental exposures. There was used a mathematical exposure model being essentially defined by application of a Monte Carlo photon transport calculation in a mathematical human phantom. Body doses were estimated for a reference man in relation to the relevant raditon quantities for different angles of incidence as a function of photon energy. The effective whole body dose defining the risk assessment of stochastic radiation effects was evaluated for the first time. There was also calculated the equivalent dose index which, with respect to radiation protection, is of special importance among the quantities characterizing radiation. The calculations indicated that for different irradiation directions in the energy range between 0.025 and 10 MeV the equivalent dose index gives a conservative estimation for the effective whole body dose. For X-ray diagnostic examinations in the body area the tissue surface dose may be regarded as an upper limit for body doses in the useful beam. The standard energy dose and the equivalent dose index are a conservative measure for important body doses in case of terrestrial radiation and fresh fall-out radiation from the ground. (orig./HP) [de

  8. Effect of 25MV whole-body x-ray irradiation on endocrinous function of pancreas of rats

    International Nuclear Information System (INIS)

    Tsubota, Motoki; Dalimunthe, D.; Kawata, Ryoso; Ito, Chikako.

    1980-01-01

    The whole body of rats was exposed once to 800 rad of 25 MVX-ray which was estimated to be median lethal dose (LD-50), and the secretion mechanism of insulin and glucagon soon after the exposure was discussed. Trasient excessive blood glucose, mild relative decrease of the level of blood insulin, and increase of the level of glucagon were observed. Insulin release from the pancreas which was perfused with 20 mM arginine was accelerated 5 hours, 1 day, 2 days, and 3 days after the exposure and glucagon release were also accelerated 1, 2, and 3 days after the exposure. The acceleration of insulin and glucagon release was higher in rats exposed to radiation than that in controls. From the above-mentioned results, it was suggested that the endocrinous function of the pancreas of rats was not damages itself even by the exposure with LD-50 of x-ray. (Tsunoda, M.)

  9. Radioprotection by dipyridamole in the aging mouse. Effects on lipid peroxidation in mouse liver, spleen and brain after whole-body X-ray irradiation

    International Nuclear Information System (INIS)

    Seino, Noritaka

    1995-01-01

    To investigate the radioprotective effect of dipyridamole in the aging mouse, the lipid peroxide content in aging mouse liver, spleen and brain irradiated by X-ray were measured both before and after injection of dipyridamole. The lipid peroxide content increased with aging from 2 months old to 16 months old in the mouse liver, spleen and brain. The content of lipid peroxide in the liver and spleen of the aging mouse was significantly increased in 7 days after whole-body irradiation with 8 Gy, but was unchanged in the brain. Dipyridamole, given before irradiation, significantly inhibited the increase of lipid peroxide after irradiation. These results suggest that dipyridamole may have radioprotective effects on aging mouse liver and spleen as well as on young mouse, and that inhibition of lipid peroxidation is a possible factor in the radioprotective effect of dipyridamole. (author)

  10. Autoradiographic studies of cell kinetics after whole body x-ray irradiation. Part 1. Mode of death of lethally injured proliferating subependymal cells in rat brain

    Energy Technology Data Exchange (ETDEWEB)

    Gracheva, N.D.

    1982-03-01

    Autoradiographic tests were performed on proliferating subependymal cells derived from the brain of Wistar rats treated with /sup 3/H-thymidine, 60 to 80 min prior to whole-body x-ray irradiation with 50, 150, or 300 R. Evaluation of the time-dependent increase in the fraction of radio-labeled cells and the two-fold lower concentration of the label in pycnotic nuclei indicated that the lethally-injured cells which were irradiated in the early G/sub 2/ and S phases were subjected to mitotic, rather than interphase, death in the first post-radiation cell cycle. Such cells underwent mitosis ca. 2 h after irradiation, showing a 1 h lag phase vis-a-vis control cells, irrespective of the radiation dose. 25 references, 5 figures.

  11. Building lab-scale x-ray tube based irradiators

    Science.gov (United States)

    The construction of economical x-ray tube based irradiators in a variety of configurations is described using 1000 Watt x-ray tubes. Single tube, double tube, and four tube designs are described, as well as various cabinet construction techniques. Relatively high dose rates were achieved for small s...

  12. Impact of X-ray irradiation on PMMA thin films

    Energy Technology Data Exchange (ETDEWEB)

    Iqbal, Saman, E-mail: saman.khan343@gmail.com [Physics Department, University of Engineering and Technology, Lahore (Pakistan); Rafique, Muhammad Shahid [Physics Department, University of Engineering and Technology, Lahore (Pakistan); Anjum, Safia [Physics Department, Lahore College for Woman University, Lahore (Pakistan); Hayat, Asma [Physics Department, University of Engineering and Technology, Lahore (Pakistan); Iqbal, Nida [Faculty of Biomedical Engineering and Health Science, Universiti Teknologi Malaysia (UTM) (Malaysia)

    2012-10-15

    Highlights: Black-Right-Pointing-Pointer PMMA thin films were deposited at 300 Degree-Sign C and 500 Degree-Sign C using PLD technique. Black-Right-Pointing-Pointer These films were irradiated with different fluence of laser produced X-rays. Black-Right-Pointing-Pointer Irradiation affects the ordered packing as well as surface morphology of film. Black-Right-Pointing-Pointer Hardness of film decreases up to certain value of X-ray fluence. Black-Right-Pointing-Pointer Absorption in UV-visible range exhibits a non linear behavior. - Abstract: The objective of this project is to explore the effect of X-ray irradiation of thin polymeric films deposited at various substrate temperatures. pulsed laser deposition (PLD) technique is used for the deposition of PMMA thin films on glass substrate at 300 Degree-Sign C and 500 Degree-Sign C. These films have been irradiated with various X-rays fluences ranging from 2.56 to 5.76 mJ cm{sup -2}. Characterization of the films (before and after the irradiation) is done with help of X-ray Diffractrometer, Optical Microscope, Vickers hardness tester and UV-vis spectroscopy techniques. From XRD data, it is revealed that ordered packing has been improved for the films deposited at 300 Degree-Sign C. However after irradiation the films exhibited the amorphous behavior regardless of the X-ray fluence. Film deposited at 500 Degree-Sign C shows amorphous structure before and after irradiation. Hardness and particle size of thin film have also increased with the increasing substrate temperature. However, the irradiation has reverse effect i.e. the particle size as well as the hardness has reduced. Irradiation has also enhanced the absorption in the UV-visible region.

  13. Impact of X-ray irradiation on PMMA thin films

    International Nuclear Information System (INIS)

    Iqbal, Saman; Rafique, Muhammad Shahid; Anjum, Safia; Hayat, Asma; Iqbal, Nida

    2012-01-01

    Highlights: ► PMMA thin films were deposited at 300 °C and 500 °C using PLD technique. ► These films were irradiated with different fluence of laser produced X-rays. ► Irradiation affects the ordered packing as well as surface morphology of film. ► Hardness of film decreases up to certain value of X-ray fluence. ► Absorption in UV–visible range exhibits a non linear behavior. - Abstract: The objective of this project is to explore the effect of X-ray irradiation of thin polymeric films deposited at various substrate temperatures. pulsed laser deposition (PLD) technique is used for the deposition of PMMA thin films on glass substrate at 300 °C and 500 °C. These films have been irradiated with various X-rays fluences ranging from 2.56 to 5.76 mJ cm −2 . Characterization of the films (before and after the irradiation) is done with help of X-ray Diffractrometer, Optical Microscope, Vickers hardness tester and UV–vis spectroscopy techniques. From XRD data, it is revealed that ordered packing has been improved for the films deposited at 300 °C. However after irradiation the films exhibited the amorphous behavior regardless of the X-ray fluence. Film deposited at 500 °C shows amorphous structure before and after irradiation. Hardness and particle size of thin film have also increased with the increasing substrate temperature. However, the irradiation has reverse effect i.e. the particle size as well as the hardness has reduced. Irradiation has also enhanced the absorption in the UV–visible region.

  14. Quality control of X-ray irradiator by biological markers

    International Nuclear Information System (INIS)

    Miura, Miwa; Lukmanul Hakkim, F.; Yoshida, Masahiro; Matsuda, Naoki; Morita, Naoko

    2011-01-01

    The exposure of animals or cultured cells to radiation is the essential and common step in experimental researches to elucidate biological effects of radiation. When an X-ray generator is used as a radiation source, physical parameters including dose, dose rate, and the energy spectrum of X-ray play crucial roles in biological outcome. Therefore, those parameters are the important points to be checked in quality control and to be carefully considered in advance to the irradiation to obtain the accurate and reproductive results. Here we measured radiation dose emitted from the X-ray irradiator for research purposes by using clonogenic survival of cultured mammalian cells as a biological marker in parallel with physical dosimetry. The results drawn from both methods exhibited good consistency in the dose distribution on the irradiation stage. Furthermore, the close relationship was observed between cell survival and the photon energy spectrum by using different filter components. These results suggest that biological dosimetry is applicable to quality control of X-ray irradiator in adjunct to physical dosimetry and that it possibly helps better understanding of the optimal irradiating condition by X-ray users in life-science field. (author)

  15. Low-energy x-ray irradiation for electrophysiological studies

    Energy Technology Data Exchange (ETDEWEB)

    Schauer, D.A.; Zeman, G.H.; Pellmar, T.C.

    1989-01-01

    High-dose-rate acute whole-body exposures have been the main focus of radiobiology research conducted at the Armed Forces Radiobiology Research Institute (AFRRI) for many years. Extensive quantitative studies have been conducted analyzing behavioral effects, radiation-induced syndromes, and combined injury phenomena. Tolliver and Pellmar initiated a study to evaluate radiation damage to brain neurophysiology. A 50-kVp molybdenum target/filter x-ray tube was installed inside a lead-shielded Faraday cage. High-dose rates of up to 1.54 Gy/min (17.4-keV weighted average photons) were used to conduct local in vitro irradiations of the hippocampal region of guinea pig brains. Electrophysiological recordings of subtle changes in neuronal activity indicate this system is suitable for this application.

  16. Degradation of organophosphorus compounds by X-ray irradiation

    International Nuclear Information System (INIS)

    Trebse, P.; Arcon, I.

    2002-01-01

    Complete text of publication follows. Our research presented in this contribution aims to elucidate the degradation mechanisms of organophosphate pesticides as organic pollutants by X-ray irradiation. Diazinon, one of the most widely used pesticides in Slovenia, has been chosen as a model compound for the study of radiation induced degradation of organophosphorus pesticides. Recent studies have shown that the degradation of the pesticide at normal conditions (room temperature, exposure to daylight) is strongly enhanced when the pesticide is exposed to UV light (Hg lamp, λ=254 nm, XeCl excimer laser, λ=308 nm). In our study we irradiated the pesticide in aqueous media with a white x-ray beam from a conventional x-ray source. Mo X-ray tube operating at the high voltage of 55 kV and a current of 45 mA was used. The flux of the continuous X-ray beam was stabilized within 1%. Saturated water solution of the pesticide (volume: 4mL, conc. of 40 mg L -1 ) was inserted in 1 cm long lucite cell with 1 mm thick lucite windows. The whole volume of the solution in the cell was exposed to the unfiltered X-ray beam. The dose rate on the sample was about 1 mGy/s. Different irradiation times between 30 min to 120 min were chosen to study the dependence of the pesticide decomposition with the absorbed dose. Solid phase extraction was employed for sample extraction from the solution, and gas chromatography was used for the identification and quantification of the compounds. The results show that the concentration of the pesticide in the solution decreases exponentially with the exposure time, i.e. with the absorbed dose. At irradiation conditions described above, the time constant of the exponential decrease was 74 min

  17. Autoradiographic studies of cell kinetics after whole body x-ray irradiation. Part 2. Postradiation death of differentiating and proliferating subependymal cells in rat brain

    Energy Technology Data Exchange (ETDEWEB)

    Gracheva, N.D.

    1982-03-01

    Post-radiation cell death in the subependymal zone of the rat brain was investigated by injection of /sub 3/H-thymidine 60 to 80 min prior to x-ray irradiation of the animals with 50, 150, or 300 R. Subsequent correlation of autoradiographic findings with the cell cycle showed that the proliferating and differentiating (D) cells followed a fluctuating pattern in cell death, in that cells irradiated in the early G/sub 2/ and the S phases showed four peaks of mitotic cell death in the first postradiation cell cycle. Cells injured in the G/sub 1/ phase lost the capacity for DNA synthesis, since the 300 R-irradiated cells failed to incorporate /sup 14/C-thymidine administered subsequently (3 H before sacrifice, 12 to 17 h after /sup 3/H-thymidine injection). Since these cells did not die within 4 h of irradiation, their death evidently came about during the first postradiation cell cycle. The cell death pattern of the D cells coincided with the death peaks and mitotic peaks of the proliferating cells, indicating that the D cells retained the rhythm and phase sequence of the mitotic cycle in the form of a short cycle. All the irradiated cells entered mitosis with a one hour delay, and the total number of cell deaths was dosage-related. 11 references, 4 figures.

  18. Radioprotection of mice by lactoferrin against irradiation with sublethal X-rays

    International Nuclear Information System (INIS)

    Nishimura, Yoshikazu; Homma-Takeda, Shino; Kim, Hee-Sun; Kakuta, Izuru

    2014-01-01

    The influence of a host defense protein, lactoferrin (LF), contained in exocrine secretions such as milk, on radiation disorder was investigated. A total of 25 C3H/He mice in each of two groups were maintained with 0.1% LF-added and LF-free diets, respectively, for one month. The mice were then treated with single whole-body X-ray irradiation at a sublethal dose (6.8 Gy), and the survival rate after irradiation was investigated. The survival rate at 30 d after irradiation was relatively higher in the LF group than in the control group (LF-free), (85 and 62%, respectively). The body weight 15 d after X-ray irradiation was also significantly greater in the LF group than in the control group. The hemoglobin level and hematocrit value were higher in the LF group at 5 d before X-ray irradiation. Another 52 mice underwent whole-body X-ray irradiation at the sublethal dose (6.8 Gy), and then LF was intraperitoneally injected once at 4 mg/animal to half of them. The survival rate in LF-treated mice 30 d after irradiation was 92%, significantly higher than in mice treated with saline (50%) (P = 0.0012). In addition, LF showed hydroxyl radical scavenger activity in vitro. These findings suggest that LF may inhibit radiation damage. (author)

  19. Effects of x-ray irradiation on mast cells and mastocalcergy in the connective tissue

    International Nuclear Information System (INIS)

    Song, H. Y.; Rhee, S. J.; Son, M. H.; Choi, K. C.

    1982-01-01

    Experiments were performed to observe the influence of x-ray irradiation on mast cells and mastocalcergy in rats. Animals were irradiated single dose of x-ray. X-ray irradiation was applied to the whole body in doses either 100 rads or 150 rads (Cobalt-60 Teletherapy Unit). One day after irradiation the rats were injected lead acetate intravenously, followed by injection of compound 48/80 in the back subcutaneously. Animals were killed by decapitation at intervals, 1 hour, 5 hours, 1 day and 6 day after subcutaneous injection. Specimens of the abdominal and back skin were fixed in alcohol formol solution and stained with the following methods; H-E for observation of pathological changes of tissues, toluidine blue for demonstration of mast cells, von Kossa-azure A for demonstration of carbonate and phosphate, and chloranilic acid for demonstration of calcium. The following conclusions were obtained. Calciphylatic wheals are large size in the control group, medium size in 100 rads irradiation group and small size in 150 rads irradiation group. In x-ray irradiation groups the number of mast cells decreases more in the 150 rads than in the 100 rads irradiation. In the 100 rads x-ray irradiation group, histochemical study of the injection sites showed that calcium impregnated to mast cell granules and connective tissue fibers in 1 days after subcutaneous injection. The morphogenesis of this calcinosis was the same in the rat of 5 hour after subcutaneous injection of the control group. Whereas, 1 day after subcutaneous injection in 150 rads x-ray irradiation group calcium deposited more slightly than other groups

  20. Radiation Safety of Gamma, Electron and X Ray Irradiation Facilities. Specific Safety Guide (Spanish Edition)

    International Nuclear Information System (INIS)

    2015-01-01

    The objective of this Safety Guide is to provide recommendations on how to meet the requirements of the BSS with regard to irradiation facilities. This Safety Guide provides specific, practical recommendations on the safe design and operation of gamma, electron and X ray irradiators for use by operating organizations and the designers of these facilities, and by regulatory bodies. SCOPE. The facilities considered in this publication include five types of irradiator, whether operated on a commercial basis or for research and development purposes. This publication is concerned with radiation safety issues and not with the uses of irradiators, nor does it cover the irradiation of product or its quality management. The five types of irradiator are: - Panoramic dry source storage irradiators; - Underwater irradiators, in which both the source and the product being irradiated are under water; - Panoramic wet source storage irradiators; - Electron beam irradiation facilities, in which irradiation is performed in an area that is potentially accessible to personnel, but that is kept inaccessible during the irradiation process; - X ray irradiation facilities, in which irradiation is performed in an area that is potentially accessible to personnel, but that is kept inaccessible during the irradiation process. Consideration of non-radiation-related risks and of the benefits resulting from the operation of irradiators is outside the scope of this Safety Guide. The practices of radiotherapy and radiography are also outside the scope of this Safety Guide. Category I gamma irradiators (i.e. 'self-shielded' irradiators) are outside the scope of this Safety Guide

  1. Effects of clinical X-ray irradiation on UHMWPE films

    Science.gov (United States)

    Stojilovic, N.; Dordevic, S. V.; Stojadinovic, S.

    2017-11-01

    Irradiation of biocompatible polymers is generally performed using 60Co gamma sources delivering high doses of radiation, ranging from kGy to MGy levels. This irradiation is typically employed for sterilization and/or crosslinking purposes. However, exposure to gamma rays may generate free radicals responsible for polymer degradation and, therefore, studies of the irradiation effects on these polymers are of great practical interest. In this study, ultra-high molecular weight polyethylene (UHMWPE) films were exposed to high-energy photons to doses comparable to those used in radiotherapy for patients with cancer. Specifically, three dose levels of 30, 60, and 120 Gy were delivered utilizing linear accelerator X-rays (6 MV) and irradiation effects were studied using X-ray Diffraction (XRD), Fourier Transform Infrared (FTIR), and Ultraviolet-visible (UV-vis) spectroscopy. It was found that radiation doses up to 120 Gy do not change the polymer crystallinity but affect its optical properties. In particular, the decrease in the optical band gap is observed in irradiated polymers.

  2. Soft X-ray fluorescence measurements of irradiated polymer films

    Science.gov (United States)

    Winarski, R. P.; Ederer, D. L.; Pivin, J.-C.; Kurmaev, E. Z.; Shamin, S. N.; Moewes, A.; Chang, G. S.; Whang, C. N.; Endo, K.; Ida, T.

    1998-11-01

    Fluorescent soft X-ray carbon Kα emission spectra (XES) have been used to characterize the bonding of carbon atoms in polyimide (PI) and polycarbosilane (PCS) films. The PI films have been irradiated with 40 keV nitrogen or argon ions, at fluences ranging from 1 × 10 14 to 1 × 10 16 cm -2. The PCS films have been irradiated with 5 × 10 15 carbon ions cm -2 of 500 keV and/or annealed at 1000°C. We find that the fine structure of the carbon XES of the PI films changes with implanted ion fluence above 1 × 10 14 cm -2 which we believe is due to the degradation of the PI into amorphous C:N:O. The width of the forbidden band as determined from the high-energy cut-off of the C Kα X-ray excitation decreases with the ion fluence. The bonding configuration of free carbon precipitates embedded in amorphous SiC which are formed in PCS after irradiation with C ions or combined treatments (irradiation and subsequent annealing) is close to either to that in diamond-like films or in silicidated graphite, respectively.

  3. X-ray photoelectron spectra of γ-irradiated perfluorobenzene

    International Nuclear Information System (INIS)

    Sunder, S.; Sagert, N.H.; Wood, D.D.; Miller, N.H.

    1990-01-01

    The effect of γ-radiolysis on perfluorobenzene (PFB) was investigated using low-temperature X-ray photoelectron spectroscopy (XPS). PFB was irradiated in fluorine-passivated nickel cells using Co 60 γ-rays in an Atomic Energy of Canada Limited Gammacell at a dose rate of about 2.6 Gy·s -1 and for a total dose of about 50 kGy. The γ-radiolysis of PFB not only results in cross-linkage but also in the formation of saturated carbon centers in the PFB, as indicated by the presence of CF 2 and CF 3 groups. The relative abundance of CF, CF 2 and CF 3 groups, in the irradiated PFB, was estimated to be about 86, 9 and 5%, respectively

  4. Food Irradiation Using Electron Beams and X-Rays

    Science.gov (United States)

    Miller, Bruce

    2003-04-01

    In this presentation we will discuss the technology of food irradiation using electron accelerators. Food irradiation has generally come to describe the use of ionizing radiation to decrease the population of, or prevent the growth of, undesirable biological organisms in food. The many beneficial applications include insect disinfestation, sprouting inhibition, delayed ripening, and the enhanced safety and sterilization of fresh and frozen meat products, seafood, and eggs. With special regard to food safety, bacteria such as Salmonella enteridis, Listeria monocytogenes, Campylobacter jejuni and Escherichia coli serotype O157:H7 are the primary causes of food poisoning in industrialized countries. Ionizing doses in the range of only 1-5 kilogray (kGy) can virtually eliminate these organisms from food, without affecting the food's sensory and nutritional qualities, and without inducing radioactivity. The key elements of an accelerator-based irradiation facility include the accelerator system, a scanning system, and a material handling system that moves the product through the beam in a precisely controlled manner. Extensive radiation shielding is necessary to reduce the external dose to acceptable levels, and a safety system is necessary to prevent accidental exposure of personnel during accelerator operation. Parameters that affect the dose distribution must be continuously monitored and controlled with process control software. The choice of electron beam vs x-ray depends on the areal density (density times thickness) of the product and the anticipated mass throughput. To eliminate nuclear activation concerns, the maximum kinetic energy of the accelerator is limited by regulation to 10 MeV for electron beams, and 5 MeV for x-rays. From penetration considerations, the largest areal density that can be treated by double-sided electron irradiation at 10 MeV is about 8.8 g/cm2. Products having greater areal densities must be processed using more penetrating x-rays. The

  5. The effect of sex differences on induction of intestinal metaplasia in x-ray irradiated rats

    International Nuclear Information System (INIS)

    Watanabe, Hiromitsu; Takizawa, Shoichi; Terada, Yoritake; Naito, Masashi; Naito, Yukiko

    1980-01-01

    The effects of sex differences and ovarian resection on induction of intestinal metaplasia in x-ray irradiated mice were discussed. 1,000 rad of x-ray was irradiated to the stomach of female and male mice twice at intervals of 3 days. The range of intestinal metaplasia in male mice was wider than that in female mice. A total of 400 rad was irradiated to the whole body of mice which underwent ovarian resection (group 1), mice which underwent autotransplantation of the ovary after ovarian resection (group 2), and mice which underwent sham-ovarian resection (group 3). The incidence of intestinal metaplasia in the group 1 was significantly higher than that in the group 3. The weight of the uterus decreased gradually in order of the group 3, group 2, and group 1. It was suggested from above-mentioned results that disappearance or lowering of femal sex hormones, that is, male or androphacy, induced intestinal metaplasia. (Tsunoda, M.)

  6. X-ray inspection of foreign bodies in foods

    International Nuclear Information System (INIS)

    Ohira, Norihiro; Hongjun, Zhou; Sakamaki, Kazumi; Kamimura, Kunio; Shimizu, Hideaki; Saiki, Hideo

    2008-01-01

    X-ray inspection system of foreign bodies in foods has become is necessary for our society in recent years, with the expectation that they could inspect not only metals but also other bodies like glass, rubber, nylon, etc. Calculation algorithms for X-ray inspection of foreign bodies in foods have been reported. In food inspection systems, it is important that inspection is high precision, with high speed that is as fast as conveyor belts. Using Statistical methods, we construct a higher precision method than usual methods. We focused on Kittler's minimum error thresholding. In the usual Kittler's method, order n-squared calculations are required for distributed calculation, so it is not suitable for high speed food inspection. We find that using approximations of variances in Kittler's method is not too critical for practical use. Using it, we be come able to inspect for foreign bodies that were not able to be inspected for so far. (author)

  7. X-ray photoelectron microscope with a compact x-ray source generated by line-focused laser irradiation

    International Nuclear Information System (INIS)

    Yamaguchi, N.; Okamoto, Y.; Hara, T.; Takahashi, Z.; Nishimura, Y.; Sakata, A.; Watanabe, K.; Azuma, H.

    2004-01-01

    Full text: A laboratory-sized microscopic system of x-ray photoelectrons has been developing using a compact x-ray source produced by line-focused laser irradiation. The system is a scanning type photoelectron microscope where x-ray beam is micro-focused via a Schwartzschild optics. A compact laser-plasma x-ray source has been developed with a YAG laser system, a line-focus lens system, a tape-target driving system and a debris prevention system, that was operated at repetition rate of 10 Hz or 50 Hz. X-rays were delivered along line plasma whose length was 0.6 to 11 mm with higher intensity than that from a point-focused source. Because the transition line of Al V (13.1 nm) was prominent in the soft x-ray spectrum when the Al tape target irradiated at the lower power density of 10 11 W/cm 2 , the 13.1 nm x-ray was used as an excitation source. The Schwartzschild optics was set on the beamline at a distance about 1 m from the source, which was coated with Mo/Si multilayers for 13.1 nm x-ray. The designed demagnification is 224 that was confirmed in the previous experiment. Therefore, an x-ray micro spot of sub-micron size can be formed on a sample surface when the source size is less than about 0.2 mm. Samples were set on a two-axis high-precision piezo stage mounted to a four-axis manipulator. The electron energy analyzer was a spherical capacitor analyzer with mean diameter of 279.4 mm. The electron detector was a microchannel plate (MCP) with a phosphor screen and the optical image of electrons on the exit plane of the analyzer was taken and recorded by using an ultra low dark noise CCD camera, that was suited for detection of vast photoelectrons excited by x-ray pulse of ns-order duration. We performed spatial resolution test measurements by using a GaAs wafer coated with photo-resist that formed a stripe pattern. The spatial resolution less than 3 micron has been obtained from the variation of As 3d electron intensity along the position of the GaAs sample

  8. Radioprotective effects of melatonin on carbon-ion and X ray irradiation in mice

    International Nuclear Information System (INIS)

    Saito, Masayoshi; Kawata, Tetsuya; Liu, C.; Sakurai, Akiko; Ito, Hisao; Ando, Koichi

    2004-01-01

    The radioprotective ability of melatonin was investigated in C3H mice irradiated to a whole-body X-ray (150 Kv, 20 mA) and carbon-ion (290 MeV/u). Mice exposed to X-ray, 13 KeV/μm and 50 KeV/μm carbon-ion dose of 7.0-7.5 Gy, 6.5-7.25 Gy and 6.0-6.5 Gy, respectively. One hour before the irradiation, mice were given an intraperitoneal injection of 0.2 ml of either solvent (soybean oil) or melatonin (250 mg/kg, uniform suspension in soybean oil). Mice were observed for mortality over a period of 30 days following irradiation. Results obtained the first year are as follows. The toxicity of melatonin (at a dose 250 mg/kg) intraperitoneal administered to mice could not be observed. A pretreatment of melatonin is effective in protecting mice from lethal damage of low-linear energy transfer (LET) irradiation (X-ray and 13 KeV/μm carbon-ion). In the high-LET irradiated mice with 50 KeV/μm carbon-ion, melatonin exhibited a slight increase in their survival. (author)

  9. Radioprotective effect of Ganoderma lucidum (Leyss. ex. Fr.) Karst after X-ray irradiation in mice

    International Nuclear Information System (INIS)

    Hsu, H.Y.; Lian, S.L.; Lin, C.C.

    1990-01-01

    Six to seven week old male mice of ICR strain were exposed to 500 or 650 cGy of X-ray during experiments to determine if Ganoderma lucidum could be a factor in modification of radiation damage. Continuous intraperitoneal injection of the extract from Ganoderma lucidum before or after irradiation of 500 and 650 cGy of X-ray was found to improve the 30-day survival fractions of ICR mice, but wasn't significant by statistical analysis. The administration also enhanced the recoveries of the body weights and increased the recovery of hemograms of irradiated mice from radiation damage by injecting before or after radiation exposure, especially for the treatment of 500 cGy irradiation. The 10-day CFUs was significantly higher for Ganoderma lucidum treated groups than for untreated groups. However, the differences of radioprotective effect between the X-ray irradiated groups with Ganoderma lucidum pretreated and post-treated were not significant (p greater than 0.05)

  10. Radioprotective effect of Ganoderma lucidum (Leyss. ex. Fr. ) Karst after X-ray irradiation in mice

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, H.Y.; Lian, S.L.; Lin, C.C. (Kaohsiung Medical College (Taiwan))

    1990-01-01

    Six to seven week old male mice of ICR strain were exposed to 500 or 650 cGy of X-ray during experiments to determine if Ganoderma lucidum could be a factor in modification of radiation damage. Continuous intraperitoneal injection of the extract from Ganoderma lucidum before or after irradiation of 500 and 650 cGy of X-ray was found to improve the 30-day survival fractions of ICR mice, but wasn't significant by statistical analysis. The administration also enhanced the recoveries of the body weights and increased the recovery of hemograms of irradiated mice from radiation damage by injecting before or after radiation exposure, especially for the treatment of 500 cGy irradiation. The 10-day CFUs was significantly higher for Ganoderma lucidum treated groups than for untreated groups. However, the differences of radioprotective effect between the X-ray irradiated groups with Ganoderma lucidum pretreated and post-treated were not significant (p greater than 0.05).

  11. Development of Laser Plasma X-ray Microbeam Irradiation System and Radiation Biological Application

    Science.gov (United States)

    Sato, Katsutoshi; Nishikino, Masaharu; Numasaki, Hodaka; Kawachi, Tetsuya; Teshima, Teruki; Nishimura, Hiroaki

    Laser plasma x-ray source has the features such as ultra short pulse, high brilliance, monochromaticity, and focusing ability. These features are excellent compared with conventional x-ray source. In order to apply the laser plasma x-ray source to the biomedical study and to more closely research the radiobilogical responce of the cancer cell such as radiation induced bystander effect, we have developed x-ray microbeam system using laser plasma x-ray source. The absorbed dose of laser plasma x-ray was estimated with Gafchromic EBT film and DNA double strand breaks on the cells were detected by immunofluorescence staining. When the cells were irradiated with laser plasma x-ray, the circular regions existing γ-H2AX positive cells were clearly identified. The usefulness of the laser plasma x-ray on the radiobiological study was proved in this research.

  12. Electron Paramagnetic Resonance studies of x-ray irradiated Nafion

    Science.gov (United States)

    Fragoso, Juan; Usher, Timothy

    2007-03-01

    Fuel cells promise a bright future as power sources for a variety of electronic equipment as well as more power demanding elements. Nafion (DuPont's trademark of a sulfonated tetrafluorethylene polymer modified from Teflon) is the heart of Proton Exchange Membrane Fuel Cells (PEMFCs) as well as Direct Methanol Fuel Cells (DMFCs). Fuel cells are used to power electronic equipment on spacecraft, satellites and unpiloted high altitude aircraft, where ionizing radiation can be a concern. Electron Paramagnetic Resonance (EPR) is a spectroscopic technique that is very sensitive to free radicals such as those produced by ionizing radiation therefore EPR can give us a window into the degradation of the Nafion membranes due to the ionizing radiation. Nafion samples were irradiated using a x-ray diffractometer with a copper target operating at 40kV and 55mA for at least 3hrs. X-Band EPR spectroscopy of the irradiated nafion reveals a peak at 3400G with a width of 10G, which decays over time, completely diminishing in a couple of weeks. Preliminary results from the polarization studies on the effects of ionizing radiation will also be presented.

  13. X ray irradiation of a galaxy by an embedded active nucleus

    International Nuclear Information System (INIS)

    Voit, G.M.

    1990-01-01

    The nuclei of active galaxies radiate a significant fraction of their prodigious luminosities in the x-ray band. These energetic photons penetrate the surrounding galaxy, altering the nature of the matter they encounter. This thesis examines the interactions of X-rays with the three major constituents of a galaxy: stars, gas, and grains. X-rays incident upon a star will heat its outer layers, driving a mass outflow from the stellar surface if the X-ray flux is sufficiently high, but the total mass released from a cluster of X-ray irradiated stars is probably insufficient to fuel the active nucleus. X-rays absorbed in weakly ionized molecular clouds create energetic photo-electrons that directly excite line-emitting transitions of H2 and He. An algorithm given here calculates the excitation yields due to X-ray photoelectrons 100 to 10,000 eV in energy over a range of fractional ionizations. When X-rays irradiate dust grains, the temperatures of the smallest grains fluctuate wildly, heating dramatically during X-ray absorption and cooling rapidly thereafter. IR spectra of X-ray irradiated dust will always turn over shortward of 3 microns, because of evaporative cooling, and will display none of the emission features that come from 3 to 5 A particles, for they will be completely evaporated after just a few X-ray heating events

  14. X-ray microprobe - A new facility for cell irradiations in Krakow

    Energy Technology Data Exchange (ETDEWEB)

    Bozek, S. [Henryk Niewodniczanski Institute of Nuclear Physics, Polish Academy of Sciences, Radzikowskiego 152, 31-342 Krakow (Poland); Jagiellonian University Medical College, ul. Medyczna 9, 30-688 Krakow (Poland); Bielecki, J. [Henryk Niewodniczanski Institute of Nuclear Physics, Polish Academy of Sciences, Radzikowskiego 152, 31-342 Krakow (Poland); Baszak, J. [Hamamatsu Photonics GmbH, Polish Office (Poland)], E-mail: jbaszak@hamamatsu.de; Doruch, H.; Hajduk, R.; Lekki, J. [Henryk Niewodniczanski Institute of Nuclear Physics, Polish Academy of Sciences, Radzikowskiego 152, 31-342 Krakow (Poland); Stachura, Z. [Henryk Niewodniczanski Institute of Nuclear Physics, Polish Academy of Sciences, Radzikowskiego 152, 31-342 Krakow (Poland)], E-mail: Zbigniew.Stachura@ifj.edu.pl; Kwiatek, W.M. [Henryk Niewodniczanski Institute of Nuclear Physics, Polish Academy of Sciences, Radzikowskiego 152, 31-342 Krakow (Poland)

    2009-06-15

    A new, multi-purpose X-ray microprobe has been constructed in Krakow. The Hamamatsu L9191 microfocusing X-ray tube is used as a source of radiation. The microprobe is equipped with three dedicated experimental lines serving for the computed microtomography (CMT), for micro-XRF or TXRF measurements (micro-X-ray induced Fluorescence, Total reflexion XRF) and for mammalian cell irradiations. Details of the construction of the experimental line dedicated to irradiations are presented.

  15. X-ray irradiation on blood products for the purpose of prevention of PT-GVHD

    International Nuclear Information System (INIS)

    Tayama, Tatsuya; Naohara, Tooru; Haneda, Kenji; Juji, Takeo.

    1990-01-01

    X-ray irradiation on blood products is a common method to prevent the risk of inducing PT-GVHD, and has recently become to be used in Japan. We have tried X-ray irradiation on WB, CRC and PC using HITACHI X-ray Irradiation Apparatus MBR1520R, and studied its practical usefulness. In case of irradiation on blood bags as the minimum dose of 1,500 rads, these conditions are thought to be practical: 1) the use of 1.0 mm Al filter, 2) the distance of 550 nm from X-ray source, and 3) irradiation on 4 bags at the same time. But, it has also been noticed that total doses and qualities of X-ray absorbed into blood were different between upper and lower side of the bag. Bloods on upper side absorbed much doses and a wide range of X-ray, on the other hand, bloods on lower side absorbed less doses and hard X-ray. In these conditions, irradiated lymphocytes showed a complete inhibition of thymidine uptake in MLC test, still had 15% of activity in PHA stimulation. The qualities of other blood components have not changed before and after irradiation. X-ray irradiation is useful in a routine work of blood center, but problems of proper doses and a uniformity of irradiation are remained to be solved. (author)

  16. Effects of X-ray irradiation on genomic DNA methylation levels in mouse tissues

    International Nuclear Information System (INIS)

    Tawa, Riichi; Sakurai, Hiromu; Kimura, Yutaka; Komura, Jun-ichiro; Miyamura, Yoshinori; Kurishita, Akihiro; Sasaki, Masao S.; Ono, Tetsuya

    1998-01-01

    Effects of ionizing radiation on the level of genomic DNA methylation in liver, brain and spleen of mouse as well as in two kinds of cultured cells were examined by high-performance liquid chromatography. Ten Gy of whole body X-radiation reduced the 5-methyldeoxycytidine contents by about 40% within 8 hours after irradiation in liver. Similar effects were observed at 4 or 7 Gy of X-ray irradiation. However, no such change was detected in brain, spleen and cultured cells. The data indicate that radiation-induced alteration in genomic DNA methylation is not ubiquitous among different tissues and cells. (author)

  17. Effect of low frequency low energy pulsing electromagnetic field (PEMF) on X-ray-irradiated mice

    International Nuclear Information System (INIS)

    Cadossi, R.; Hentz, V.R.; Kipp, J.

    1989-01-01

    C3H/Km flora-defined mice were used to investigate the effect of exposure to pulsing electromagnetic field (PEMF) after total body x-ray irradiation. Prolonged exposure to PEMF had no effect on normal nonirradiated mice. When mice irradiated with different doses of x-ray (8.5 Gy, 6.8 Gy, and 6.3 Gy) were exposed to PEMF 24 h a day, we observed a more rapid decline in white blood cells (WBC) in the peripheral blood of mice exposed to PEMF at all the x-ray dosages used. No effect of exposure to PEMF was observed on the survival of the mice irradiated with 6.3 Gy and 8.5 Gy; in mice irradiated with 6.8 Gy, 2 out of 12 survived when exposed to PEMF as compared to 10 out of 12 control mice that were irradiated only. At day 4 after irradiation autoradiographic studies performed on bone marrow and spleen of 8.5-Gy-irradiated mice showed no difference between controls and mice exposed to PEMF, whereas on 6.8-Gy mice the bone marrow labeling index was lower in mice exposed to PEMF. In mice irradiated to 6.3 Gy we observed that the recovery of WBC in the peripheral blood was slowed in mice exposed to PEMF and their body weight was significantly lower than in control mice that were irradiated only. The spleen and bone marrow of the mice irradiated to 6.3 Gy and sacrificed at days 4, 14, 20, and 25 after irradiation were analyzed by autoradiography to evaluate the labeling index. Half of the spleens from mice sacrificed at day 25 after irradiation were used to evaluate the RNA content. Autoradiography showed that in the spleen and bone marrow of control mice, there were more cells labeled with [3H]thymidine at days 4 and 14 and less at days 20 and 25 after irradiation in comparison with mice irradiated and exposed to PEMF

  18. Effect of low frequency low energy pulsing electromagnetic field (PEMF) on X-ray-irradiated mice

    Energy Technology Data Exchange (ETDEWEB)

    Cadossi, R.; Hentz, V.R.; Kipp, J.; Eiverson, R.; Ceccherelli, G.; Zucchini, P.; Emilia, G.; Torelli, G.; Franceschi, C.; Cossarizza, A.

    1989-02-01

    C3H/Km flora-defined mice were used to investigate the effect of exposure to pulsing electromagnetic field (PEMF) after total body x-ray irradiation. Prolonged exposure to PEMF had no effect on normal nonirradiated mice. When mice irradiated with different doses of x-ray (8.5 Gy, 6.8 Gy, and 6.3 Gy) were exposed to PEMF 24 h a day, we observed a more rapid decline in white blood cells (WBC) in the peripheral blood of mice exposed to PEMF at all the x-ray dosages used. No effect of exposure to PEMF was observed on the survival of the mice irradiated with 6.3 Gy and 8.5 Gy; in mice irradiated with 6.8 Gy, 2 out of 12 survived when exposed to PEMF as compared to 10 out of 12 control mice that were irradiated only. At day 4 after irradiation autoradiographic studies performed on bone marrow and spleen of 8.5-Gy-irradiated mice showed no difference between controls and mice exposed to PEMF, whereas on 6.8-Gy mice the bone marrow labeling index was lower in mice exposed to PEMF. In mice irradiated to 6.3 Gy we observed that the recovery of WBC in the peripheral blood was slowed in mice exposed to PEMF and their body weight was significantly lower than in control mice that were irradiated only. The spleen and bone marrow of the mice irradiated to 6.3 Gy and sacrificed at days 4, 14, 20, and 25 after irradiation were analyzed by autoradiography to evaluate the labeling index. Half of the spleens from mice sacrificed at day 25 after irradiation were used to evaluate the RNA content. Autoradiography showed that in the spleen and bone marrow of control mice, there were more cells labeled with (3H)thymidine at days 4 and 14 and less at days 20 and 25 after irradiation in comparison with mice irradiated and exposed to PEMF.

  19. Measurement of sugar and ph in X-ray irradiated honey | Inyang ...

    African Journals Online (AJOL)

    Honey samples collected from Obudu, Nigeria were irradiated at X-ray tube potentials between 50kVp and 90kVp (typical diagnostic potentials) and analysed for possible changes in pH and sugar concentration. It was observed that X-ray irradiation of Honey actually causes changes in its pH and sugar concentration, which ...

  20. SCT-4800T whole body X-ray CT scanner

    International Nuclear Information System (INIS)

    Okumura, Yoshitaka; Sato, Yukio; Kuwahara, Hiroshi

    1994-01-01

    A whole body X-ray CT scanner, the SCT-4800T (trade name: INTELLECT series), has been developed. This system is the first CT scanner that is combined with general radiographic functions. The general radiographic functions include a patient couch with film casette and several tube support systems along with the CT scanner. This newly designed CT scanner also features a compact and light-weight gantry with a 700 mm diameter apperture and user-friendly operater's console. The SCT-4800T brings a new level of patient and operator comfort to the emergency radiology examination site. (author)

  1. Radioprotective effect of chitosan in sub-lethally X-ray irradiated mice

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Yoshikazu; Ikota, Nobuo; Arima, Hiromi; Watanabe, Yoshito; Yukawa, Masae; Ozawa, Toshihiko [National Inst. of Radiological Sciences, Chiba (Japan); Kim, Hee-Sun [Korea Hydro and Nuclear Power Corp., Seoul (Korea, Republic of). Radiation Health Research Inst.; Bom, Hee-Seung; Kim, Young-Ho [Chonnam Univ., Kwangju (Korea, Republic of). Hospital

    2003-03-01

    The radioprotective effect of chitosan was studied in mice following whole-body X-ray irradiation. C3H/He mice were exposed to 7 Gy, and their survival rates were examined. The survival rates of chitosan-diet mice were about 20% higher than those of mice on a standard diet, and the rates dropped sharply to a plateau at day 10 after X-ray irradiation. The chitosan-diet mice had an increased weight ratio of spleen to body within the experimental period. The leukocyte, thrombocyte, and erythrocyte counts as well as the hematocrit and hemoglobin levels were recovered significantly and more rapidly in the chitosan-diet mice than the standard-diet mice at day 14 after irradiation. The scavenging abilities of chitosan were evaluated by the electron spin resonance (ESR) spin-trapping method. These observations suggested that chitosan led to hematopoetic activation and leuko-cytogenesis in mice after sub-lethal dose irradiation, and that the biological response might be caused by radical trapping or scavenging. (author)

  2. Simulation of medical irradiation and X-ray detector signals

    Energy Technology Data Exchange (ETDEWEB)

    Kreisler, Bjoern

    2010-02-08

    -Carlo simulation of the irradiation head of the medical linear accelerator is constructed for the irradiation with electrons and photons in the second part of this thesis. The simulation is validated by comparison with water phantom measurements. Available information from the measurements is limited to the depth dose deposition and dose profiles in selected water depths. The simulation allows the evaluation of dose depositions and spectral particle distributions at various locations. In the electron irradiation mode, a collimation close to the patient is performed by an electron applicator. A possible reduction of the side leakage is evaluated by optimising the collimation of the beam. Medical irradiation with MeV-electrons and X-ray photons is the part of the clinical tumour treatment which is evaluated in this work. (orig.)

  3. Simulation of medical irradiation and X-ray detector signals

    International Nuclear Information System (INIS)

    Kreisler, Bjoern

    2010-01-01

    the irradiation head of the medical linear accelerator is constructed for the irradiation with electrons and photons in the second part of this thesis. The simulation is validated by comparison with water phantom measurements. Available information from the measurements is limited to the depth dose deposition and dose profiles in selected water depths. The simulation allows the evaluation of dose depositions and spectral particle distributions at various locations. In the electron irradiation mode, a collimation close to the patient is performed by an electron applicator. A possible reduction of the side leakage is evaluated by optimising the collimation of the beam. Medical irradiation with MeV-electrons and X-ray photons is the part of the clinical tumour treatment which is evaluated in this work. (orig.)

  4. A new rabbit model of impaired wound healing in an X-ray-irradiated field.

    Directory of Open Access Journals (Sweden)

    Kazutoshi Fujita

    Full Text Available Radiation is an important therapy for cancer with many benefits; however, its side effects, such as impaired wound healing, are a major problem. While many attempts have been made to overcome this particular disadvantage, there are few effective treatments for impaired wound healing in an X-ray-irradiated field. One reason for this deficiency is the lack of experimental models, especially animal models. We have previously reported a mouse model of impaired wound healing in which the irradiation area was restricted to the hindlimbs. In this mouse model, due to the size of the animal, a diameter of five millimeters was considered the largest wound size suitable for the model. In addition, the transplanted cells had to be harvested from other inbred animals. To investigate larger wounds and the impact of autologous specimen delivery, a rabbit model was developed. Rabbits were kept in a special apparatus to shield the body and hindlimbs while the irradiation field was exposed to radiation. Six weeks after irradiation, a 2 x 2 cm, full-thickness skin defect was made inside the irradiation field. Then, the wound area was observed over time. The wound area after irradiation was larger than that without irradiation at all time points. Both angiogenesis and collagen formation were reduced. For further study, as an example of using this model, the effect of autologous platelet-rich plasma (PRP was observed. Autologous PRP from peripheral blood (pb-PRP and bone marrow aspirate (bm-PRP was processed and injected into the wounds in the irradiated field. Two weeks later, the wounds treated with bm-PRP were significantly smaller than those treated with phosphate buffer vehicle controls. In contrast, the wounds treated with pb-PRP were not significantly different from the controls. This rabbit model is useful for investigating the mechanism of impaired wound healing in an X-ray-irradiated field.

  5. The response of mouse skin to re-irradiation with x-rays or fast neutrons

    International Nuclear Information System (INIS)

    Tsukiyama, Iwao; Egawa, Sunao; Kumazawa, Akiyoshi; Iino, Yuu.

    1986-01-01

    Effects of neutrons and x-rays on mouse skin which had been previously irradiated with x-rays were investigated. Two tattoo marks were placed in the hairless legs of mice at intervals of 15 mm. The legs were exposed to various doses of x-ray and neutrons to determine the relative biological effectiveness (RBE) using the contraction of the skin as an index. The RBE was 0.93 - 1.73. The legs of the mice were preexposed to 25 Gy of x-ray, and exposed 4 months later. The contraction of the skin began earlier than after the first irradiation. RBE was 2.18 - 2.47. This RBE was higher than that in untreated mice. These results suggest that previously irradiated normal tissues are much more sensitive to neutrons than to x-rays. (author)

  6. Short irradiation time characteristics of the inverter type X-ray generator

    International Nuclear Information System (INIS)

    Miyazaki, Shigeru; Hara, Takamitu; Matutani, Kazuo; Saito, Kazuhiko.

    1994-01-01

    The linearity of the X-ray output is an important factor in radiography. It is a composite of the linearities of the X-ray tube voltage, the X-ray tube current, and the exposure time. This paper focuses on the linearity of exposure time. Non-linearity of the X-ray output for short-time exposure became a problem when the three-phase X-ray generator was introduced. This paper describes the inverter-type X-ray generator, which is expected to become predominant in the future. Previously, we investigated X-ray output linearity during short-time exposure using the technique of dynamic study. In this paper, we describe the application of a digital memory and a personal computer to further investigation. The non-linearity of the X-ray output was caused by irregular waveforms of the X-ray tube voltage found at the rise time and the fall time. When the rise time was about 0.6 ms, the non-linearity was about 2%, which is negligibly small. The non-linearity due to the fall time of the X-ray tube varied greatly according to the X-ray tube current. For the minimum irradiation time of 1 ms, 4% to 27% of the non-linearity was attributable to the fall time. The main cause was the stray capacitance of the X-ray high-voltage cables. When the X-ray tube current exceeded 400 mA, the rise time was almost equal to the fall time, and the problem did not occur. Consequently, the ideal generator should have a fall time which is equal to the rise time of the X-ray tube voltage. Strictly speaking, such a generator should have rectangular waveforms. (author)

  7. Silicon trench photodiodes on a wafer for efficient X-ray-to-current signal conversion using side-X-ray-irradiation mode

    Science.gov (United States)

    Ariyoshi, Tetsuya; Takane, Yuta; Iwasa, Jumpei; Sakamoto, Kenji; Baba, Akiyoshi; Arima, Yutaka

    2018-04-01

    In this paper, we report a direct-conversion-type X-ray sensor composed of trench-structured silicon photodiodes, which achieves a high X-ray-to-current conversion efficiency under side X-ray irradiation. The silicon X-ray sensor with a length of 22.6 mm and a trench depth of 300 µm was fabricated using a single-poly single-metal 0.35 µm process. X-rays with a tube voltage of 80 kV were irradiated along the trench photodiode from the side of the test chip. The theoretical limit of X-ray-to-current conversion efficiency of 83.8% was achieved at a low reverse bias voltage of 25 V. The X-ray-to-electrical signal conversion efficiency of conventional indirect-conversion-type X-ray sensors is about 10%. Therefore, the developed sensor has a conversion efficiency that is about eight times higher than that of conventional sensors. It is expected that the developed X-ray sensor will be able to markedly lower the radiation dose required for X-ray diagnoses.

  8. Hard X-ray irradiation of cosmic silicate analogs: structural evolution and astrophysical implications

    Science.gov (United States)

    Gavilan, L.; Jäger, C.; Simionovici, A.; Lemaire, J. L.; Sabri, T.; Foy, E.; Yagoubi, S.; Henning, T.; Salomon, D.; Martinez-Criado, G.

    2016-03-01

    Context. Protoplanetary disks, interstellar clouds, and active galactic nuclei contain X-ray-dominated regions. X-rays interact with the dust and gas present in such environments. While a few laboratory X-ray irradiation experiments have been performed on ices, X-ray irradiation experiments on bare cosmic dust analogs have been scarce up to now. Aims: Our goal is to study the effects of hard X-rays on cosmic dust analogs via in situ X-ray diffraction. By using a hard X-ray synchrotron nanobeam, we seek to simulate cumulative X-ray exposure on dust grains during their lifetime in these astrophysical environments and provide an upper limit on the effect of hard X-rays on dust grain structure. Methods: We prepared enstatite (MgSiO3) nanograins, which are analogs to cosmic silicates, via the melting-quenching technique. These amorphous grains were then annealed to obtain polycrystalline grains. These were characterized via scanning electron microscopy (SEM) and high-resolution transmission electron microscopy (HRTEM) before irradiation. Powder samples were prepared in X-ray transparent substrates and were irradiated with hard X-rays nanobeams (29.4 keV) provided by beamline ID16B of the European Synchrotron Radiation Facility (Grenoble). X-ray diffraction images were recorded in transmission mode, and the ensuing diffractograms were analyzed as a function of the total X-ray exposure time. Results: We detected the amorphization of polycrystalline silicates embedded in an organic matrix after an accumulated X-ray exposure of 6.4 × 1027 eV cm-2. Pure crystalline silicate grains (without resin) do not exhibit amorphization. None of the amorphous silicate samples (pure and embedded in resin) underwent crystallization. We analyze the evolution of the polycrystalline sample embedded in an organic matrix as a function of X-ray exposure. Conclusions: Loss of diffraction peak intensity, peak broadening, and the disappearance of discrete spots and arcs reveal the amorphization

  9. Toxicological and radiological safety of chicken meat irradiated with 7.5 MeV X-rays

    Science.gov (United States)

    Song, Beom-Seok; Lee, Yunjong; Park, Jong-Heum; Kim, Jae-Kyung; Park, Ha-Young; Kim, Dong-Ho; Kim, Chang-Jong; Kang, Il-Jun

    2018-03-01

    This study was conducted to evaluate the toxicological and radiological safety of chicken meat that had been irradiated at 30 kGy with 7.5 MeV X-rays. In a sub-chronic toxicity study, ICR mice were fed X-ray-irradiated chicken meat at 2500 mg/kg body weight daily for 90 days, and no mortality or abnormal clinical signs were observed throughout the study period. However, several hematological and serum biochemical parameters of the ICR mice differed significantly from those in the control group; nevertheless, the observed values were all within the normal range for the respective parameters. In addition, no toxicological effects were determined in male or female mice. Furthermore, no differences in gamma-ray spectrometric patterns were detected between the non-irradiated and irradiated samples, indicating that the radioactivity induced by 7.5 MeV X-ray irradiation was below the detection limit. These results tentatively suggest that chicken meat irradiated with 7.5 MeV X-rays would be safe for human consumption in terms of toxicology and radiology.

  10. Irradiated ISM : Discriminating between cosmic rays and X-rays

    NARCIS (Netherlands)

    Meijerink, R.; Spaans, M.; Israel, F. P.

    2006-01-01

    The interstellar medium ( ISM) at the centers of active galaxies is exposed to a combination of cosmic-ray, far-ultraviolet (FUV), and X-ray radiation. We apply photodissociation region (PDR) models to this ISM with both "normal" and highly elevated (5 x 10(-15) s(-1)) cosmic- ray (CR) rates and

  11. Detectability of Sungrazing Comet Soft X-ray Irradiance

    Directory of Open Access Journals (Sweden)

    Su Yeon Oh

    2007-12-01

    Full Text Available Originating from the Oort cloud, some comets disappear to impact against the Sun or to split up by strong gravitational force. Then they don't go back to the Oort cloud. They are called sungrazing comets. The comets are detected by sublimation of ices and ejection of gas and dust through solar heat close to the Sun. There exists the charge transfer from heavy ions in the solar wind to neutral atoms in the cometary atmosphere by interaction with the solar wind. Cometary atoms would be excited to high electronic levels and their de-excitation would result in X-ray emission, or it would be scattering of solar X-ray emission by very small cometary grains. We calculated the X-ray emission applying the model suggested by Mendis & Flammer (1984 and Cravens (1997. In our estimation, the sungrazing comet whose nucleus size is about 1 km in radius might be detectable within a distance of 3 solar radius from the sun on soft X-ray solar camera.

  12. Effects of low-dose continuously fractionated X-ray irradiation on murine peripheral blood lymphocytes

    International Nuclear Information System (INIS)

    Xie Yi; Zhang Hong; Dang Bingrong; Hao Jifang; Guo Hongyun; Wang Xiaohu

    2007-01-01

    For estimating biological risks from low doses continual irradiation, we investigated the effects of exposure to continuously fractionated X-rays on murine immune system. The BALB/c mice were irradiated with 0.07Gy at the first day and 0.08 Gy/d in the following 12 days at a dose rate of 0.2 Gy/min. The peripheral blood lymphocyte cycle and death were determined by flow cytometry at the cumulative doses of 0, 0.07, 0.23, 0.39, 0.55, 0.71, 0.87 and 1.03 Gy respectively. The results showed that the cycle of peripheral blood lymphocyte was arrested in G 0 /G 1 at cumulative doses of 0.07, 0.23, 0.71 and 0.87 Gy, and in G 2 /M at cumulative doses of 0.39 and 1.03 Gy; the percentage of death of peripheral blood lymphocyte was ascended with dose increasing, and reached the death peak at cumulative doses of 0.71 Gy. The results suggested that low doses continual X-rays total-body irradiated could result in changes of cellular cycle and death, and some damages to immunocytes, which accorded to linear square model. (authors)

  13. Influence of X-ray irradiation on metabolic effects of adrenaline

    International Nuclear Information System (INIS)

    Szyszko, A.

    1976-01-01

    Effects of X-ray irradiation in the whole-body dose of 650 R on changes in glycogen levels in liver, and in either diaphragm and skeletal muscles, and on blood glucose levels, induced in 10 min by adrenaline, were investigated in starved mice. One day after the exposure, the drops in liver glycogen levels due to starvation were found to be highly reduced by previous irradiation. This resulted in an over dozen-fold relative elevation of liver glycogen content in relation to starved not irradiated mice. The post-irradiation accumulation of liver glycogen was found to disappear after administration of adrenaline. Also in diaphragm and skeletal muscles, the changes in muscle glycogen content, induced by irradiation of starved mice, have turned out to be abolished or even reversed by adrenaline, what reflected in reduction of elevated levels and elevation of those reduced. In starved mice during first three days following irradition, adrenaline was found to be ineffective in increasing blood sugar levels, whereas this its effects was noted in either not irradiated mice or on the fourth day after irradiation. (author)

  14. Effect of X-ray irradiation on the physical and chemical quality of ...

    African Journals Online (AJOL)

    The use of irradiation as a phytosanitary treatment has expanded in recent years. It plays important roles in developed and developing countries, facilitating international trade in irradiated fresh fruit. To evaluate the potential of X-ray irradiation as a quarantine treatment for America red globe grapes, we investigated the ...

  15. Destroying the photoelectret in Bi12SiO20 by X-ray irradiation

    International Nuclear Information System (INIS)

    Vavrek, A. F.; Khristova, K. K.

    1987-01-01

    The destroying of the classical photoelectret state (PES) in bismuth silicon oxide (BSO) monocrystals during X-ray irradiation is investigated and the reciprocity law (RL) is examined. The sample is irradiated by nonfiltered X-rays with continuous spectrum and maximum energy of the photons 70 keV. The polaryzing voltage used is 85 V. The dependence of the destroyed PE charge on the time of X-ray irradiation of the sample with equal X-ray exposure in each point shows that the exposure rates higher than a certain 'critical' value cause a larger destroyed charge that is RL during X-ray irradiation. The 'critical' value is about 3x10 -5 A/kg. The dependence of the destroyed photoelectric (PE) charge on the irradiation time generally shows that the destroyed PE charge increases with the increase of the X-ray exposure. After some time the distruction of the charge is terminated and the sample seems to lose its X-ray sensitivity although a considerable PE charge (30-40% of the initial one) remains in it. At higher exposure rates (above the critical one for the RL) the maxmimum destroyed charge is smaller. According to the dependencies of the linear coefficients of X-ray attenuation in the investigated energy range the photoelectric absorption is dominating. The radiation is absorbed only in the near-surface region. Part of the sample remains nonexited and the PE charge which has been initially barrier distributed is destroyed as a result of the redistribution of the charges in the excitation region only. At sufficiently long irradiation time this redistribution is terminated, notwithstanding the fact that out of the excitation region the sample still remains polarized. The maximum destroyed PE charge during nonhomogeneous excitation under nonquasi-stationary conditions is smaller at higher exposure rates because of the lower values of the diffusion and drift length

  16. Effects of various drugs on recovery of immunological function after x-ray irradiation

    International Nuclear Information System (INIS)

    Fukuda, Sakae; Komori, Shoichiro; Aramaki, Shojiro; Tamai, Kazunori; Fuyuno, Kikuo

    1977-01-01

    X-ray of 300 R was irradiation to the whole bodies of mice aged 6 to 8 weeks, and 0.2 mg of Cepharanthin, 0.2 mg of Leucon, 0.2 ml of Cytochrome-C, and 0.01 KE of Picibanil were given intraperitoneally for seven days from the next day of the irradiation. Three days after the administration of these drugs, 0.1 ml of 7% picrylchloride ethanol solution was painted on the shaven abdomen and its sensitization was examined. Next, 0.02 to 0.03 ml of 1% picrylchloride olive solution was painted on both ears 7 days after that, and swelling of them was measured with the thickness of ears 24 hours after the painting. Moreover, the sensitization was discussed from a viewpoint of the number of leukocyte and lymphocute. Delayed-type skin reaction which was an index of cellular immunity was influenced fairly by the whole body irradiation of x-ray, but it recovered from the damage 20 to 30 days after the irradiation, showing rebound-like phenomenon. Recovery of delayed-type skin reaction and the number of lymphocyte showed almost the same pattern. Accordingly, it was suspected that the number of lymphocyte was directly proportional to cellular immunological competence of the individual. Out of four drugs, there was not a drug particularly which activated delayed-type skin reaction. In contrast with this, Leucon and Cytochrome-C significantly inhibited the recovery. It was recognized that four drugs had a tendency to promote the recovery of the number of leucocyte, but they decreased it conversely from a viewpoint of percentage of lymphocyte. Therefore, it was suspected that the subject of this would be an increase of leukocyte except lymphocyte. (Ueda, J.)

  17. X-ray emission from stainless steel foils irradiated by femtosecond petawatt laser pulses

    Science.gov (United States)

    Alkhimova, M. A.; Faenov, A. Ya; Pikuz, T. A.; Skobelev, I. Yu; Pikuz, S. A.; Nishiuchi, M.; Sakaki, H.; Pirozhkov, A. S.; Sagisaka, S.; Dover, N. P.; Kondo, Ko; Ogura, K.; Fukuda, Y.; Kiriyama, H.; Esirkepov, T.; Bulanov, S. V.; Andreev, A.; Kando, M.; Zhidkov, A.; Nishitani, K.; Miyahara, T.; Watanabe, Y.; Kodama, R.; Kondo, K.

    2018-01-01

    We report about nonlinear growth of x-ray emission intensity emitted from plasma generated by femtosecond petawatt laser pulses irradiating stainless steel foils. X-ray emission intensity increases as ∼ I 4.5 with laser intensity I on a target. High spectrally resolved x-ray emission from front and rear surfaces of 5 μm thickness stainless steel targets were obtained at the wavelength range 1.7–2.1 Å, for the first time in experiments at femtosecond petawatt laser facility J-KAREN-P. Total intensity of front x-ray spectra three times dominates to rear side spectra for maximum laser intensity I ≈ 3.2×1021 W/cm2. Growth of x-ray emission is mostly determined by contribution of bremsstrahlung radiation that allowed estimating bulk electron plasma temperature for various magnitude of laser intensity on target.

  18. X-ray irradiation-induced structural modifications in PM-355 polymeric nuclear track detector film

    Science.gov (United States)

    Nouh, S. A.; Bahareth, Radiyah A.; Abutalib, M. M.

    2014-06-01

    Samples from sheets of the polymeric material PM-355 have been exposed to X-rays from a 50 kV X-ray tube in the dose range of 10-300 kGy. The resultant effect of X-ray irradiation on the structural properties of PM-355 has been investigated using different techniques such as X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopy, Vickers hardness and refractive index measurements. The results indicate that the X-ray irradiation of PM-355 in the dose range of 10-20 kGy causes initially chain scission. Above 20 and up to 100 kGy, the active free radicals produced from scission contribute to chemical reactions that lead to the crosslinking. Thus, the X-ray irradiation in the dose range of 20-100 kGy leads to a more compact structure of the PM-355 polymer, resulting in an enhancement of its Vickers hardness and refractive index. Moreover, the irradiation in the dose range of 100-300 kGy leads to the predominance of the degradation. This degradation is reported by FTIR spectroscopy and enhances the degree of ordering in the degraded samples as revealed by XRD technique. Additionally, it decreases both the Vickers hardness and refractive index of the PM-355 samples.

  19. Supercrystallization of KCl from solution irradiated by soft X-rays

    Science.gov (United States)

    Janavičius, A. J.; Rinkūnas, R.; Purlys, R.

    2016-10-01

    The X-rays influence on KCl crystallization in a saturated water solution has been investigated for the aim of comparing it with previously considered NaCl crystallization. The rate of crystallization has been measured in the drying drop in the solution activated by the irradiation. We have measured the influence of the irradiation time of the solution on the rates of KCl crystallization as well as the beginning of the crystallization processes on drying drops. For a longer irradiation time of the solution early crystallization in the drops occurs. A saturated water solution of KCl was irradiated with the diffractometer DRON-3M (Russian device) and this had a great influence on the two-step processes of crystallization. The ionization of the solution by soft X-rays can produce ions, metastable radicals in water, excited crystals' seeds and vacancies in growing crystals by Auger's effect. The X-rays generate a very fast crystallization in the drying drop.

  20. Analysis of microstress in neutron irradiated polyester fibre by X-ray ...

    Indian Academy of Sciences (India)

    Unknown

    Abstract. Microstresses developed in the crystallites of polymeric material due to irradiation of high-energy particle causes peak broadening and shifting of X-ray diffraction lines to lower angle. Neutron irradiation significantly changes the material properties by displacement of lattice atoms and the generation of helium.

  1. Analysis of microstress in neutron irradiated polyester fibre by X-ray ...

    Indian Academy of Sciences (India)

    Microstresses developed in the crystallites of polymeric material due to irradiation of high-energy particle causes peak broadening and shifting of X-ray diffraction lines to lower angle. Neutron irradiation significantly changes the material properties by displacement of lattice atoms and the generation of helium and hydrogen ...

  2. X-ray diffraction studies of sucrose and sucrose irradiated with γ-radiation

    International Nuclear Information System (INIS)

    Prasad, Mahendra

    1981-01-01

    In order to understand and solve numerous problems related to sugar quality and its storage life, X-ray diffraction studies of sucrose and sucrose irradiated with γ-radiation have been made. It is observed that the interplanar spacing 'd' in irradiated sucrose is reduced indicating the partial damage of sucrose lattice. (author)

  3. CubeSAT X-ray Telescope (CubeX) for Elemental Abundance Mapping of Airless Bodies and X-ray Pulsar Navigation (XNAV)

    Science.gov (United States)

    Romaine, S.; Hong, J.; Elvis, M.

    2017-09-01

    The CubeSAT X-ray Telescope (CubeX) is a concept for a 12U planetary X-ray telescope, which utilizes Miniature Wolter-I X-ray optics (MiXO) and a combination of X-ray CMOS and SDD sensors for the focal plane. CubeX will map the surface elemental composition of diverse airless bodies using X-ray Fluorescence (XRF), which can help us to understand the formation and evolutionary history of the individual bodies and the workings of the Solar system as a whole. CubeX will also conduct a feasibility and performance test of X-ray pulsar timing based deep space navigation (XNAV), which can lower operation costs of space navigation and enable autonomous deep space navigation.

  4. Neural induced embryoid bodies present high levels of metals detected by x-ray microfluorescence

    International Nuclear Information System (INIS)

    Stelling, Mariana P.; Cardoso, Simone C.; Paulsen, Bruna S.; Rehen, Stevens K.

    2012-01-01

    Molecular mechanisms driving neural differentiation in human embryonic stem cells are not completely elucidated, specially, the role of atomic elements within this process. In this work, we described the distribution of trace elements in those stem cells growing as embryoid bodies by using synchrotron radiation X-ray microfluorescence (SR-XRF). Naive and neural induced embryoid bodies derived from embryonic stem cells were irradiated with a spatial resolution of 20 μm to make elemental maps and qualitative chemical analyses. We consistently detected metallic elements content raise on neural induced embryoid bodies, mimicking characteristic brain development. The use of SR-XRF reveals that human embryoid bodies exhibit self-organization at the atomic level, which is enhanced during neurogenesis triggered in vitro.

  5. Neural induced embryoid bodies present high levels of metals detected by x-ray microfluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Stelling, Mariana P.; Cardoso, Simone C.; Paulsen, Bruna S.; Rehen, Stevens K. [Instituto de Ciencias Biomedicas, Universidade Federal do Rio de Janeiro, Av. Carlos Chagas, 373 (Brazil); Instituto de Fisica, Universidade Federal do Rio de Janeiro, Av. Athos da Silveira Ramos, 14, 21941 Rio de Janeiro (Brazil); Instituto de Ciencias Biomedicas, Universidade Federal do Rio de Janeiro, Av. Carlos Chagas, 373 (Brazil)

    2012-05-17

    Molecular mechanisms driving neural differentiation in human embryonic stem cells are not completely elucidated, specially, the role of atomic elements within this process. In this work, we described the distribution of trace elements in those stem cells growing as embryoid bodies by using synchrotron radiation X-ray microfluorescence (SR-XRF). Naive and neural induced embryoid bodies derived from embryonic stem cells were irradiated with a spatial resolution of 20 {mu}m to make elemental maps and qualitative chemical analyses. We consistently detected metallic elements content raise on neural induced embryoid bodies, mimicking characteristic brain development. The use of SR-XRF reveals that human embryoid bodies exhibit self-organization at the atomic level, which is enhanced during neurogenesis triggered in vitro.

  6. Neural induced embryoid bodies present high levels of metals detected by x-ray microfluorescence

    Science.gov (United States)

    Stelling, Mariana P.; Cardoso, Simone C.; Paulsen, Bruna S.; Rehen, Stevens K.

    2012-05-01

    Molecular mechanisms driving neural differentiation in human embryonic stem cells are not completely elucidated, specially, the role of atomic elements within this process. In this work, we described the distribution of trace elements in those stem cells growing as embryoid bodies by using synchrotron radiation X-ray microfluorescence (SR-XRF). Naive and neural induced embryoid bodies derived from embryonic stem cells were irradiated with a spatial resolution of 20 μm to make elemental maps and qualitative chemical analyses. We consistently detected metallic elements content raise on neural induced embryoid bodies, mimicking characteristic brain development. The use of SR-XRF reveals that human embryoid bodies exhibit self-organization at the atomic level, which is enhanced during neurogenesis triggered in vitro.

  7. X-ray irradiation induced reversible resistance change in Pt/TiO2/Pt cells.

    Science.gov (United States)

    Chang, Seo Hyoung; Kim, Jungho; Phatak, Charudatta; D'Aquila, Kenneth; Kim, Seong Keun; Kim, Jiyoon; Song, Seul Ji; Hwang, Cheol Seong; Eastman, Jeffrey A; Freeland, John W; Hong, Seungbum

    2014-02-25

    The interaction between X-rays and matter is an intriguing topic for both fundamental science and possible applications. In particular, synchrotron-based brilliant X-ray beams have been used as a powerful diagnostic tool to unveil nanoscale phenomena in functional materials. However, it has not been widely investigated how functional materials respond to the brilliant X-rays. Here, we report the X-ray-induced reversible resistance change in 40-nm-thick TiO2 films sandwiched by Pt top and bottom electrodes, and propose the physical mechanism behind the emergent phenomenon. Our findings indicate that there exists a photovoltaic-like effect, which modulates the resistance reversibly by a few orders of magnitude, depending on the intensity of impinging X-rays. We found that this effect, combined with the X-ray irradiation induced phase transition confirmed by transmission electron microscopy, triggers a nonvolatile reversible resistance change. Understanding X-ray-controlled reversible resistance changes can provide possibilities to control initial resistance states of functional materials, which could be useful for future information and energy storage devices.

  8. Study on the inactivation of intracellular enzyme molecules by X-ray irradiation

    International Nuclear Information System (INIS)

    Lee, S.B.

    1977-01-01

    Inactivation of the glutamic acid dehydrogenase and glucose-6-phosphate dehydrogenase enzyme molecules in the Ehrlich ascites tumor cells of the mouse were studied. The above mentioned intracellular enzyme molecules were irradiated by the X-ray radiation under the condition of 65 kV, 1 Amp under the atmosphere of nitrogen gases and by 4 0 C. Thereby, irradiation doses were 580 KR/min(error: +-3%). After irradiation, the cell homogentes were prepared through liquid air techniques. There after, the activities of the enzymes were measured with photometric method given by O. Warburg and W. Christian. The dose effect curves of the activities of the two enzymes by the X-ray irradiation showed both exponential and the inactivation doses were 6.5x10 6 and 5.0x10 6 R respectively. These results showed one side that the inactivation process of the intracellular enzyme molecules was one hit reaction after target theory, and the other side that this inactivation process could not be the primary causes of the death through X-ray irradiation of the vertebrate animals, because of the high resistance of the intracellular protein molecules against X-ray irradiation. The one hit reaction by the inactivation process of the irradiated intracellular enzyme molecules was discussed. (author)

  9. Influence of neutron irradiation on the microstructure of nuclear graphite: An X-ray diffraction study

    Science.gov (United States)

    Zhou, Z.; Bouwman, W. G.; Schut, H.; van Staveren, T. O.; Heijna, M. C. R.; Pappas, C.

    2017-04-01

    Neutron irradiation effects on the microstructure of nuclear graphite have been investigated by X-ray diffraction on virgin and low doses (∼ 1.3 and ∼ 2.2 dpa), high temperature (750° C) irradiated samples. The diffraction patterns were interpreted using a model, which takes into account the turbostratic disorder. Besides the lattice constants, the model introduces two distinct coherent lengths in the c-axis and the basal plane, that characterise the volumes from which X-rays are scattered coherently. The methodology used in this work allows to quantify the effect of irradiation damage on the microstructure of nuclear graphite seen by X-ray diffraction. The results show that the changes of the deduced structural parameters are in agreement with previous observations from electron microscopy, but not directly related to macroscopic changes.

  10. Effects of proton irradiation on structure of NdFeB permanent magnets studied by X-ray diffraction and X-ray absorption fine structure

    International Nuclear Information System (INIS)

    Yang, L.; Zhen, L.; Xu, C.Y.; Sun, X.Y.; Shao, W.Z.

    2011-01-01

    The effects of proton irradiation on the structure of NdFeB permanent magnet were investigated by X-ray diffraction and X-ray absorption fine structure (XAFS). The results reveal that proton irradiation has no effect on the long-range structure, but significantly affects the atomic local structure of the NdFeB magnet. The alignment degree of the magnet decreases and the internal stress of the lattice increases after proton irradiation. XAFS results show that the coordination number of Fe-Nd in the first neighboring coordination shell of the Fe atoms decreases and the disorder degree increases.

  11. Effects of proton irradiation on structure of NdFeB permanent magnets studied by X-ray diffraction and X-ray absorption fine structure

    Energy Technology Data Exchange (ETDEWEB)

    Yang, L. [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China); Zhen, L., E-mail: lzhen@hit.edu.c [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China); Xu, C.Y.; Sun, X.Y.; Shao, W.Z. [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China)

    2011-01-15

    The effects of proton irradiation on the structure of NdFeB permanent magnet were investigated by X-ray diffraction and X-ray absorption fine structure (XAFS). The results reveal that proton irradiation has no effect on the long-range structure, but significantly affects the atomic local structure of the NdFeB magnet. The alignment degree of the magnet decreases and the internal stress of the lattice increases after proton irradiation. XAFS results show that the coordination number of Fe-Nd in the first neighboring coordination shell of the Fe atoms decreases and the disorder degree increases.

  12. Regularity of wound healing in rats irradiated locally with different doses of soft X-rays

    International Nuclear Information System (INIS)

    Liu Jianzhong; Zhou Yuanguo; Cheng Tianmin; Zhou Ping; Liu Xia; Li Ping

    2002-01-01

    Objective: To study the regular patter of wound healing in rats irradiated locally with different doses of soft X-rays. Methods: Rats were locally irradiated, and wounded immediately thereafter. Gross observation, histopathology and immunohistochemistry examinations, and image analysis were used to study the wound healing process. Results: The authors found that the delayed time of wound healing induced by soft X-ray irradiation of 0.50, 1.01, 1.96, 3,26, 4.00, 5.21 Gy was 1.6, 4.2, 5.4, 6.6, 8.2 and 9.4 days, respectively. Irradiation with 7.0 and 10.0 Gy caused failure of wound healing (up to 40 days). Compared to the non-irradiated wounds, the healing rates of irradiation-impaired wounds were lower during the whole healing process. From day 3 to day 9 after irradiation, the healing rates decreased along with increasing of the radiation dose, indicating the key phase of wound healing was delayed. After irradiation, the collagen synthesis was decreased, its arrangement was disordered, and the structure of granulation tissue was irregular. Conclusion: Soft X-rays irradiation may cause a delay of wound healing in a dose-dependent manner, and irradiation with 7.0 and 10.0 Gy cause failure of wound healing

  13. High linolenic acid mutant in soybean induced by X-ray irradiation

    International Nuclear Information System (INIS)

    Takagi, Y.; Hossain, A.B.M.M.; Yanagita, T.; Kusaba, S.

    1989-01-01

    Soybean [Glycine max (L.) Merr. cv. Bay] seeds were irradiated with X-rays (25kR) and the M 2 progeny was screened for changes in the fatty acid composition of seed oil. X-ray irradiation remarkably increased the variability of the fatty acid composition in the oil of the Bay cultivar. A mutant in which linolenic acid accounted for 18.4 per cent of the total oil cornpared with 9.4 per cent in the Bay cultivar was identified among 2006 M 2 plants. The M 3 generation of the mutant also showed a linolenic acid content approximately two times higher than that of the original variety

  14. Development of X-ray photoelectron microscope with a compact X-ray source generated by line-focused laser irradiation

    International Nuclear Information System (INIS)

    Yamaguchi, N.; Takahashi, Z.; Nishimura, Y.; Watanabe, K.; Okamoto, Y.; Sakata, A.; Azuma, H.; Hara, T.

    2005-01-01

    A laboratory-sized X-ray photoelectron microscope was constructed using a compact X-ray source produced by line-focused laser irradiation. The system is a scanning type photoelectron microscope where X-ray beam is micro-focused via Schwarzschild optics. A compact laser-plasma X-ray source has been developed with a YAG laser, a line-focus lens assembly, an Al tape-target driver and a debris prevention system. The 13.1 nm X-ray was delivered along line plasma whose length was 0.6 or 11 mm with higher intensity than that from a point-focused source. The Schwarzschild optics having the designed demagnification of 224, which was coated with Mo/Si multilayers for 13.1 nm X-ray, was set on the beamline 1 m distant from the source. The electron energy analyser was a spherical capacitor analyser with the photoelectron image detection system that was suited for detection of vast photoelectrons excited by an X-ray pulse of ns-order duration. The spatial resolution less than 5 μm has been confirmed from the variation of As 3d electron intensity along the position of the GaAs sample coated with a photo-resist test pattern

  15. Long-term storage method for soft X-ray irradiated 'Hyuganatsu' pollen

    International Nuclear Information System (INIS)

    Yano, S.; Tanaka, M.; Ohara, N.

    2008-01-01

    The long-term storage conditions for 'Hyuganatsu ' pollen that had been irradiated with soft X-rays was examined. This study, was aimed at production of 'Tosa-buntan' without formation of nuclear fruit. 1. We evaluated the germination rate of pollen that had been irradiated with soft X-ray (500 or 1,000 Gy) and stored at 3 deg C, -20 deg C, and -40 deg C. The germination rate was the same as that of unirradiated pollen, even after storage for 1 year. Soft X-ray irradiation did not influence the storage attributes of pollen. 2. In unirradiated pollen and pollen that had been irradiated with soft X-ray (500 or 1,000 Gy), temperature conditions necessary for storing from 3 months to 1 year were -20 deg C or less, and pollen stored at -40 deg C had a higher germination rate after 1 year. 3. The germination rate was 1% or less in 4 months if silica gel was sealed into a gas barrier bag with 1,000 Gy-irradiated pollen at a rate of 10:1 (w/w). The ability to germinate was completely lost after 1 year in these conditions. 4. We evaluated the effect of sealing methods on 1,000 Gy-irradiated pollen stored at -20 deg C. There was no difference in germination rates among pollen stored in gas-barrier bags, vacuum-packaged pollen, and pollen stored with nitrogen in gas-barrier bags. Moreover, the germination rate of 750 Gy-irradiated pollen stored at -20 deg C decreased from 3 months onwards when pollen was stored with a free-oxygen absorber (Ageless ZP). 5. Pollen that was treated with acetone before or after soft X-ray irradiation (750 Gy) withstood long-term storage of 1 year. Long-term storage was possible if pollen was stored at -20 deg C, as is the case for rough pollen

  16. Irradiation with X-rays phase-advances the molecular clockwork in liver, adrenal gland and pancreas.

    Science.gov (United States)

    Müller, Mareike Hildegard; Rödel, Franz; Rüb, Udo; Korf, Horst-Werner

    2015-02-01

    The circadian clock of man and mammals shows a hierarchic organization. The master clock, located in the suprachiasmatic nuclei (SCN), controls peripheral oscillators distributed throughout the body. Rhythm generation depends on molecular clockworks based on transcriptional/translational interaction of clock genes. Numerous studies have shown that the clockwork in peripheral oscillators is capable to maintain circadian rhythms for several cycles in vitro, i.e. in the absence of signals from the SCN. The aim of the present study is to analyze the effects of irradiation with X-rays on the clockwork of liver, adrenal and pancreas. To this end organotypic slice cultures of liver (OLSC) and organotypic explant cultures of adrenal glands (OAEC) and pancreas (OPEC) were prepared from transgenic mPer2(luc) mice which express luciferase under the control of the promoter of an important clock gene, Per2, and allow to study the dynamics of the molecular clockwork by bioluminometry. The preparations were cultured in a membrane-based liquid-air interface culturing system and irradiated with X-rays at doses of 10 Gy and 50 Gy or left untreated. Bioluminometric real-time recordings show a stable oscillation of all OLSC, OAEC and OPEC for up to 12 days in vitro. Oscillations persist after irradiation with X-rays. However, a dose of 50 Gy caused a phase advance in the rhythm of the OLSC by 5 h, in the OPEC by 7 h and in the OAEC by 6 h. Our study shows that X-rays affect the molecular clockwork in liver, pancreas and adrenal leading to phase advances. Our results confirm and extend previous studies showing a phase-advancing effect of X-rays at the level of the whole animal and single cells.

  17. Whole body x-ray CT scanner, TCT-900S

    International Nuclear Information System (INIS)

    Mori, Issei; Saito, Kiyoto; Asahina, Kiyotaka

    1987-01-01

    The fundamental parameters of an X-ray CT (computed tomography) scanner are temporal, spatial, and density resolution. Research projects to improve these parameters had reached a standstill until recently. Toshiba has achieved a breakthrough with the development of a new CT system, the TCT-900S, which incorporates a new scanning configuration and several technological improvements. The TCT-900S is already in clinical use in many hospitals nationwide, and new diagnostic applications are being explored. (author)

  18. X-ray microbeam stand-alone facility for cultured cells irradiation

    International Nuclear Information System (INIS)

    Bożek, Sebastian; Bielecki, Jakub; Wiecheć, Anna; Lekki, Janusz; Stachura, Zbigniew; Pogoda, Katarzyna; Lipiec, Ewelina; Tkocz, Konrad; Kwiatek, Wojciech M.

    2017-01-01

    Highlights: • An X-ray microbeam line for irradiation of living cultured cells was constructed. • A step by step explanation of working principles with engineering details, procedures and calculations is presented. • A model of beam and cell interaction is presented. • A method of uniform irradiation of living cells with an exact dose per a cell is presented. • Results of preliminary experiments are presented. - Abstract: The article describes an X-ray microbeam standalone facility dedicated for irradiation of living cultured cells. The article can serve as an advice for such facilities construction, as it begins from engineering details, through mathematical modeling and experimental procedures, ending up with preliminary experimental results and conclusions. The presented system consists of an open type X-ray tube with microfocusing down to about 2 μm, an X-ray focusing system with optical elements arranged in the nested Kirckpatrick-Baez (or Montel) geometry, a sample stand and an optical microscope with a scientific digital CCD camera. For the beam visualisation an X-ray sensitive CCD camera and a spectral detector are used, as well as a scintillator screen combined with the microscope. A method of precise one by one irradiation of previously chosen cells is presented, as well as a fast method of uniform irradiation of a chosen sample area. Mathematical models of beam and cell with calculations of kerma and dose are presented. The experiments on dose-effect relationship, kinetics of DNA double strand breaks repair, as well as micronuclei observation were performed on PC-3 (Prostate Cancer) cultured cells. The cells were seeded and irradiated on Mylar foil, which covered a hole drilled in the Petri dish. DNA lesions were visualised with γ-H2AX marker combined with Alexa Fluor 488 fluorescent dye.

  19. X-ray microbeam stand-alone facility for cultured cells irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Bożek, Sebastian, E-mail: sebastian.bozek@yahoo.com [Jagiellonian University Medical College, Department of Pharmaceutical Biophysics, Krakow (Poland); Bielecki, Jakub; Wiecheć, Anna; Lekki, Janusz; Stachura, Zbigniew; Pogoda, Katarzyna; Lipiec, Ewelina; Tkocz, Konrad; Kwiatek, Wojciech M. [Institute of Nuclear Physics Polish Academy of Sciences, PL-31342 Krakow (Poland)

    2017-03-01

    Highlights: • An X-ray microbeam line for irradiation of living cultured cells was constructed. • A step by step explanation of working principles with engineering details, procedures and calculations is presented. • A model of beam and cell interaction is presented. • A method of uniform irradiation of living cells with an exact dose per a cell is presented. • Results of preliminary experiments are presented. - Abstract: The article describes an X-ray microbeam standalone facility dedicated for irradiation of living cultured cells. The article can serve as an advice for such facilities construction, as it begins from engineering details, through mathematical modeling and experimental procedures, ending up with preliminary experimental results and conclusions. The presented system consists of an open type X-ray tube with microfocusing down to about 2 μm, an X-ray focusing system with optical elements arranged in the nested Kirckpatrick-Baez (or Montel) geometry, a sample stand and an optical microscope with a scientific digital CCD camera. For the beam visualisation an X-ray sensitive CCD camera and a spectral detector are used, as well as a scintillator screen combined with the microscope. A method of precise one by one irradiation of previously chosen cells is presented, as well as a fast method of uniform irradiation of a chosen sample area. Mathematical models of beam and cell with calculations of kerma and dose are presented. The experiments on dose-effect relationship, kinetics of DNA double strand breaks repair, as well as micronuclei observation were performed on PC-3 (Prostate Cancer) cultured cells. The cells were seeded and irradiated on Mylar foil, which covered a hole drilled in the Petri dish. DNA lesions were visualised with γ-H2AX marker combined with Alexa Fluor 488 fluorescent dye.

  20. Development of a low-energy x-ray camera for the imaging of secondary electron bremsstrahlung x-ray emitted during proton irradiation for range estimation.

    Science.gov (United States)

    Ando, Koki; Yamaguchi, Mitsutaka; Yamamoto, Seiichi; Toshito, Toshiyuki; Kawachi, Naoki

    2017-06-21

    Imaging of secondary electron bremsstrahlung x-ray emitted during proton irradiation is a possible method for measurement of the proton beam distribution in phantom. However, it is not clear that the method is used for range estimation of protons. For this purpose, we developed a low-energy x-ray camera and conducted imaging of the bremsstrahlung x-ray produced during irradiation of proton beams. We used a 20 mm  ×  20 mm  ×  1 mm finely grooved GAGG scintillator that was optically coupled to a one-inch square high quantum efficiency (HQE)-type position-sensitive photomultiplier tube to form an imaging detector. The imaging detector was encased in a 2 cm-thick tungsten container, and a pinhole collimator was attached to its camera head. After performance of the camera was evaluated, secondary electron bremsstrahlung x-ray imaging was conducted during irradiation of the proton beams for three different proton energies, and the results were compared with Monte Carlo simulation as well as calculated value. The system spatial resolution and sensitivity of the developed x-ray camera with 1.5 mm-diameter pinhole collimator were estimated to be 32 mm FWHM and 5.2  ×  10 -7 for ~35 keV x-ray photons at 100 cm from the collimator surface, respectively. We could image the proton beam tracks by measuring the secondary electron bremsstrahlung x-ray during irradiation of the proton beams, and the ranges for different proton energies could be estimated from the images. The measured ranges from the images were well matched with the Monte Carlo simulation, and slightly smaller than the calculated values. We confirmed that the imaging of the secondary electron bremsstrahlung x-ray emitted during proton irradiation with the developed x-ray camera has the potential to be a new tool for proton range estimations.

  1. Improvement of mungbean by X-ray and thermal neutron irradiation

    International Nuclear Information System (INIS)

    Kwon, S.H.; Oh, J.H.

    1983-01-01

    With the aim of improving yield, resistance to Cercospora leaf spot and pod shattering, mungbean varieties Kyunggi No. 5 and M-317 were irradiated with X-rays and thermal neutrons. High yielding mutant lines are generally characterized by a higher number of pods per plant. Better Cercospora resistance appears often associated with later maturity. Satisfactory shattering resistance was not yet obtained. (author)

  2. Analysis of microstress in neutron irradiated polyester fibre by X-ray ...

    Indian Academy of Sciences (India)

    Unknown

    2. Principle. The strains developed in the crystallites due to radiation heating or irradiation manifest as changes in the lattice planes, causing line shifting. These changes in the lattice planes are measured by the X-ray diffraction method. Microstress causes diffraction line broadening, while macro- stress causes line shifting.

  3. Analysis of microstress in neutron irradiated polyester fibre by X-ray ...

    Indian Academy of Sciences (India)

    ... Analytical X-ray diffractometer and the effects of microstresses in tensile strength of fibre measured by Instron have also been reported. The shift of 0.45 cm-1 in the Raman peak position of 1614.65 cm-1 to a higher value confirmed the development of microstresses due to neutron irradiation using micro-Raman technique.

  4. Ac-electrical conductivity of poly(propylene) before and after X-ray irradiation

    International Nuclear Information System (INIS)

    Gaafar, M.

    2001-01-01

    Study on the ac-electrical conductivity of poly(propylene), before and after X-ray irradiation within the temperature range 300-360 K are reported. The measurements have been performed in a wide range of frequencies (from 0 to 10 5 Hz) and under the effect of different X-ray irradiation doses (from 0 to 15 Gy). Cole-Cole diagrams have been used to show the frequency dependence of the complex impedance at different temperatures. The results exhibit semicircles which are consistent with existing equivalent circuit model. Analysis of the results reveal semiconducting features based mainly on a hopping mechanism. The study shows a pronounced effect of X-ray irradiation on the electrical conductivity at zero frequency σ DC . At the early stage of irradiation, σ DC increased as a result of free radical formation. As the irradiation progressed, it decreased as a result of crosslinking, then it increased again due to irradiation induced degradation, which motivates the generation of mobile free radicals. The study shows that this polymer is one among other polymers which its electrical conductivity is modified by irradiation

  5. Ac-electrical conductivity of poly(propylene) before and after X-ray irradiation

    Science.gov (United States)

    Gaafar, M.

    2001-05-01

    Study on the ac-electrical conductivity of poly(propylene), before and after X-ray irradiation within the temperature range 300-360 K are reported. The measurements have been performed in a wide range of frequencies (from 0 to 10 5 Hz) and under the effect of different X-ray irradiation doses (from 0 to 15 Gy). Cole-Cole diagrams have been used to show the frequency dependence of the complex impedance at different temperatures. The results exhibit semicircles which are consistent with existing equivalent circuit model. Analysis of the results reveal semiconducting features based mainly on a hopping mechanism. The study shows a pronounced effect of X-ray irradiation on the electrical conductivity at zero frequency σDC. At the early stage of irradiation, σDC increased as a result of free radical formation. As the irradiation progressed, it decreased as a result of crosslinking, then it increased again due to irradiation induced degradation, which motivates the generation of mobile free radicals. The study shows that this polymer is one among other polymers which its electrical conductivity is modified by irradiation.

  6. X-ray diffraction in laser-irradiated epsomite crystals grown in presence of borax

    International Nuclear Information System (INIS)

    Zaitseva, E.V.; Portnov, V.N.; Faddeev, M.A.; Chuprunov, E.V.

    1997-01-01

    Relative changes in the intensities ΔI/I of the (220) and (440) X-ray diffraction reflection during laser irradiation of epsomite (MgSO 2 ·7H 2 O) crystals grown from an aqueous solution in the presence of borax (Na 2 B 4 O 7 ·10H 2 O) were measured using the CoK α , CuK α , MoK α radiations. The intensities measured depend on the real crystal structure dependent on the borax content in the solution. The dependence of ΔI/I is studied as a function of borax in the solution and X-ray-radiation wavelength

  7. Larval x-ray irradiation influences protein expression in pupae of the Oriental fruit fly, Bactrocera Dorsalis

    Science.gov (United States)

    Third instar larvae were exposed to X-ray treatment of the Oriental fruit fly, Bactrocera dorsalis. Irradiated pupae were collected daily. Biological performance parameters of pupae and adults of larvae treated with X-ray irradiation were evaluated. Standard proteomics procedures such as densitometr...

  8. Quality of fresh-cut purple fleshed sweet potatoes after x-ray irradiation treatment and refrigerated storage

    Science.gov (United States)

    The effect of x-ray irradiation on the quality of fresh-cut, refrigerated purple-fleshed sweetpotato (PFSP) cubes was investigated. Packaged sweetpotato cubes were treated with 0, 250, 500, 750 or 1000 Gy x-ray irradiation and stored at 4 ± 1 ºC for 14 days. After 14 days, total aerobic bacteria cou...

  9. Electrophysiologic and cellular characteristics of cardiomyocytes after X-ray irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Frieß, Johannes L., E-mail: johannes.friess@h-ab.de [University for Applied Sciences Aschaffenburg, biomems lab, Würzburger Straße 45, 63743 Aschaffenburg (Germany); Heselich, Anja [Technische Universität Darmstadt, Developmental Biology and Neurogenetics, Schnittspahnstraße 13, 64287 Darmstadt (Germany); Ritter, Sylvia [Helmholtz Institute for Heavy Ion Research (GSI), Biophysics Department, Planckstraße 1, 64291 Darmstadt (Germany); Haber, Angelina; Kaiser, Nicole; Layer, Paul G. [Technische Universität Darmstadt, Developmental Biology and Neurogenetics, Schnittspahnstraße 13, 64287 Darmstadt (Germany); Thielemann, Christiane [University for Applied Sciences Aschaffenburg, biomems lab, Würzburger Straße 45, 63743 Aschaffenburg (Germany)

    2015-07-15

    Highlights: • Electrophysiologic and cellular effects of X-rays on primary cardiac cell cultures. • X-ray doses between 0.5 and 7 Gy. • Higher beat rate at reduced field action potential durations 7 days after exposure. • More increased cell cycle checkpoint arrest in G2/M than in G1/S phase. • Induced DSBs were mostly repaired within 24 h after irradiation. - Abstract: The aim of this study was to investigate possible effects of ionizing irradiation on the electrophysiological functionality of cardiac myocytes in vitro. Primary chicken cardiomyocytes with spontaneous beating activity were irradiated with X-rays (dose range of 0.5–7 Gy). Functional alterations of cardiac cell cultures were evaluated up to 7 days after irradiation using microelectrode arrays. As examined endpoints, cell proliferation, apoptosis, reactive oxygen species (ROS) and DNA damage were evaluated. The beat rate of the cardiac networks increased in a dose-dependent manner over one week. The duration of single action potentials was slightly shortened. Additionally, we observed lower numbers of mitotic and S-phase cells at certain time points after irradiation. Also, the number of cells with γH2AX foci increased as a function of the dose. No significant changes in the level of ROS were detected. Induction of apoptosis was generally negligibly low. This is the first report to directly show alterations in cardiac electrophysiology caused by ionizing radiation, which were detectable up to one week after irradiation.

  10. Electrophysiologic and cellular characteristics of cardiomyocytes after X-ray irradiation

    International Nuclear Information System (INIS)

    Frieß, Johannes L.; Heselich, Anja; Ritter, Sylvia; Haber, Angelina; Kaiser, Nicole; Layer, Paul G.; Thielemann, Christiane

    2015-01-01

    Highlights: • Electrophysiologic and cellular effects of X-rays on primary cardiac cell cultures. • X-ray doses between 0.5 and 7 Gy. • Higher beat rate at reduced field action potential durations 7 days after exposure. • More increased cell cycle checkpoint arrest in G2/M than in G1/S phase. • Induced DSBs were mostly repaired within 24 h after irradiation. - Abstract: The aim of this study was to investigate possible effects of ionizing irradiation on the electrophysiological functionality of cardiac myocytes in vitro. Primary chicken cardiomyocytes with spontaneous beating activity were irradiated with X-rays (dose range of 0.5–7 Gy). Functional alterations of cardiac cell cultures were evaluated up to 7 days after irradiation using microelectrode arrays. As examined endpoints, cell proliferation, apoptosis, reactive oxygen species (ROS) and DNA damage were evaluated. The beat rate of the cardiac networks increased in a dose-dependent manner over one week. The duration of single action potentials was slightly shortened. Additionally, we observed lower numbers of mitotic and S-phase cells at certain time points after irradiation. Also, the number of cells with γH2AX foci increased as a function of the dose. No significant changes in the level of ROS were detected. Induction of apoptosis was generally negligibly low. This is the first report to directly show alterations in cardiac electrophysiology caused by ionizing radiation, which were detectable up to one week after irradiation

  11. An evaluation of low-energy x-ray and cobalt-60 irradiations of MOS transistors

    International Nuclear Information System (INIS)

    Dozier, C.M.; Fleetwood, D.M.

    1987-01-01

    An evaluation of methodologies for irradiating MOS transistors with low-energy x-ray and Co-60 sources has been performed. The authors find that comparisons of voltage shifts produced by bulk trapped charge and interface states in MOS transistors irradiated using two different low energy x-ray sources (an ARACOR 10 keV W source and an 8 keV Cu source) agree to within better than 30 percent. This quality of agreement is similar in magnitude to that between MOS devices irradiated by different Co-60 sources. In contrast, the measurements indicate that interlaboratory comparisons of ratios of shifts produced by x-ray and Co-60 sources can lead to differences in ratios as large as a factor of --1.7. Improved electron-hole recombination data for oxides is presented. This recombination correction, in conjunction with a correction for interface dose enhancement, is used to predict the ratios of shifts produced by x-ray and Co-60 sources. However, the results show that corrections for electron-hole recombination and interface does enhancement do not, by themselves, adequately predict the field dependent behavior of these transistors

  12. The irradiation action on human dental tissue by X-rays and electrons. A nanoindenter study

    Energy Technology Data Exchange (ETDEWEB)

    Fraenzel, Wolfgang [Halle-Wittenberg Univ., Halle (Germany). Dept. of Physics; Gerlach, Reinhard [Halle-Wittenberg Univ., Halle (Germany). Clinic of Radiation Therapy

    2009-07-01

    It is known that ionizing radiation is used in medicine for Roentgen diagnostics and for radiation therapy. The radiation interacts with matter, in particular with biological one, essentially by scattering, photoelectric effect, Compton effect and pair production. To what extent the biological material is changed thereby, depends on the type and the amount of radiation energy, on the dose and on the tissue constitution. In modern radiation therapy two different kinds of radiation are used: high energy X-rays and electron radiation. In the case of head-neck tumors the general practice is an irradiation with high energy X-rays with absorbed dose to water up to 70 Gy. Teeth destruction has been identified as a side effect during irradiation. In addition, damage to the salivary glands is often observed which leads to a decrease or even the complete loss of the salivary secretion (xerostomia). This study shows how the different energy and radiation types damage the tooth tissue. The effects of both, high X-ray energy and high energy electrons, on the mechanical properties hardness and elasticity of the human dental tissue are measured by the nanoindentation technique. We compare these results with the effect of the irradiation of low X-ray energy on the dental tissue. (orig.)

  13. The irradiation action on human dental tissue by X-rays and electrons. A nanoindenter study

    International Nuclear Information System (INIS)

    Fraenzel, Wolfgang; Gerlach, Reinhard

    2009-01-01

    It is known that ionizing radiation is used in medicine for Roentgen diagnostics and for radiation therapy. The radiation interacts with matter, in particular with biological one, essentially by scattering, photoelectric effect, Compton effect and pair production. To what extent the biological material is changed thereby, depends on the type and the amount of radiation energy, on the dose and on the tissue constitution. In modern radiation therapy two different kinds of radiation are used: high energy X-rays and electron radiation. In the case of head-neck tumors the general practice is an irradiation with high energy X-rays with absorbed dose to water up to 70 Gy. Teeth destruction has been identified as a side effect during irradiation. In addition, damage to the salivary glands is often observed which leads to a decrease or even the complete loss of the salivary secretion (xerostomia). This study shows how the different energy and radiation types damage the tooth tissue. The effects of both, high X-ray energy and high energy electrons, on the mechanical properties hardness and elasticity of the human dental tissue are measured by the nanoindentation technique. We compare these results with the effect of the irradiation of low X-ray energy on the dental tissue. (orig.)

  14. X-ray microanalysis of electron-dense bodies in Cladosporium resinae

    International Nuclear Information System (INIS)

    Hobbs, G.; Griffiths, A.J.; Hann, A.O.C.

    1986-01-01

    One of the structural changes which occur in Cladosporium resinae during growth on hydrocarbons is the formation of electron-dense bodies. In this paper we report the results of X-ray microanalysis and X-ray mapping, which have shown that these bodies are associated with high concentrations of calcium and phosphorus. Such accumulation of these elements is probably a reflection of the low growth rates which appear to be characteristic of growth of C. resinae on hydrocarbons. (Auth.)

  15. Soft x ray emission spectra from laser-irradiated high-Z targets

    Science.gov (United States)

    Mehlman, G.; Burkhalter, P. G.; Newman, D. A.; Ripin, B. H.

    1990-06-01

    X ray data were acquired from mass-limited targets with the Pharos III laser system. Targets, mounted at the tip of thin glass stalks, were microscopic pieces of single or multiple high-Z element composition. The laser irradiance was 4 x 10(exp 14) W/sq cm with about 300J of focused 1.05 microns wavelength laser beam. A convex KAP crystal spectrograph was used for its capability to collect high resolution spectra in the 4 to 20 A soft x ray region. The recorded spectral film densities were microdensitometered and converted by computer-processing to absolute continuum and emission line intensities. The spectral features were identified with the aid of ab-initio atomic structure calculations. The continuum background was evaluated as a source of pseudo-continua for absorption studies of soft x rays.

  16. Verification of a novel method for tube voltage constancy measurement of orthovoltage x-ray irradiators.

    Science.gov (United States)

    Wang, Chu; Belley, Matthew D; Chao, Nelson J; Dewhirst, Mark W; Yoshizumi, Terry

    2014-08-01

    For orthovoltage x-ray irradiators, the tube voltage is one of the most fundamental system parameters as this directly relates to the dosimetry in radiation biology studies; however, to the best of our knowledge, there is no commercial portable quality assurance (QA) tool to directly test the constancy of the tube voltage greater than 160 kV. The purpose of this study is to establish the Beam Quality Index (BQI), a quantity strongly correlated to the tube voltage, as an alternative parameter for the verification of the tube voltage as part of the QA program of orthovoltage x-ray irradiators. A multipurpose QA meter and its associated data acquisition software were used to customize the measurement parameters to measure the BQI and collect its time-plot. BQI measurements were performed at 320 kV with four filtration levels on three orthovoltage x-ray irradiators of the same model, one of which had been recently energy-calibrated at the factory. For each of the four filtration levels, the measured BQI values were in good agreement (tube voltage for orthovoltage irradiators. The time-plot of BQI offers information on the behavior of beam energy at different phases of the irradiation time line. In addition, this would provide power supply performance characteristics from initial ramp-up to plateau, and finally, the sharp drop-off at the end of the exposure.

  17. Effects of ginger extract on testis enzymes of X-ray irradiated mice

    International Nuclear Information System (INIS)

    Zhao Shuhua; Li Jingshun; Wang Chunhua; Pan Qin; Yang Qiong

    2005-01-01

    Objective: To research the effects of extract of ginger on testis enzymes of X-ray irradiated mice. Methods: Mice were treated with three different doses of extract of ginger: high dose (9.3 mL·kg -1 ), middle dose (4.7 mL·kg -1 ), and low dose (2.3 mL·kg -1 ). All mice were irradiated once with 2.0 Gy X-ray. At the same time, the negative group (treated with vegetable oil only) and positive one (irradiated as well as extract of ginger groups after treated with vegetable oil) were set up. The changes of activities of enzymes in testes of mice were observed. Results: After irradiated, in the group of high dose the activity of G-6-PD was decreased but the activity of LDH was increased (P 0.05). In every group, SDH had no significant difference (P>0.05). Conclusion: The proper dose of extract of ginger has significant effects on stabilization of testis enzymes of X-ray irradiated mice. (authors)

  18. Analysis of Giant-nucleated Cell Formation Following X-ray and Proton Irradiations

    Science.gov (United States)

    Almahwasi, Ashraf Abdu

    Radiation-induced genetic instability has been observed in survivors of irradiated cancerous and normal cells in vitro and in vivo and has been determined in different forms, such as delayed cell death, chromosomal aberration or mutation. A well defined and characterized normal human-diploid AG1522 fibroblast cell line was used to study giant-nucleated cell (GCs) formation as the ultimate endpoint of this research. The average nuclear cross-sectional areas of the AG1522 cells were measured in mum2. The doubling time required by the AG1522 cells to divide was measured. The potential toxicity of the Hoechst dye at a working concentration on the live AG1522 cells was assessed. The yield of giant cells was determined at 7, 14 and 21 days after exposure to equivalent clinical doses of 0.2, 1 or 2 Gy of X-ray or proton irradiation. Significant differences were found to exist between X-ray or proton irradiation when compared with sham-irradiated control populations. The frequency of GCs induced by X-rays was also compared to those formed in proton irradiated cultures. The results confirm that 1 Gy X-rays are shown to induce higher rates of mitotically arrested GCs, increasing continually over time up to 21 days post-irradiation. The yield of GCs was significantly greater (10%) compared to those formed in proton populations (2%) 21 days postirradiation. The GCs can undergo a prolonged mitotic arrest that significantly increases the length of cell cycle. The arrest of GCs at the mitotic phase for longer periods of time might be indicative of a strategy for cell survival, as it increases the time available for DNA repair and enables an alternative route to division for the cells. However, the reduction in their formation 21 days after both types of radiation might favour GCs formation, ultimately contributing to carcinogenesis or cancer therapy resistance. The X-ray experiments revealed a dose-dependent increase in the GCs up to 14 days after irradiation. Although the proton

  19. Effect of propolis feeding on rat tissues damaged by X-ray irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Hoon; Seo, Eul Won [Andong National Univ., Andong (Korea, Republic of); Ji, Tae Jeong [Kaya Univ., Goryeong (Korea, Republic of)

    2007-06-15

    Present study aimed to investigate the radioprotective effects of propolis feeding on rat tissues damaged by X-ray irradiation. It was shown that the number of white blood cell in X-ray irradiated group supplemented with propolis increased as much to those of the control group and also the GOT activities among the blood components were decreased after propolis feeding. The mineral contents such as Mg, Fe, Ca, Mn, Cu, Mo, Ni, As in liver were increased as compared with those of the control group but maintained lower level than those of only irradiated groups, implying that the propolis feeding elevated the recovery capability of white blood cell effectively and propolis have a potential resistance to cell damage by X-ray. According to histological observations of the testis, intestine and liver tissues which are irradiated after feeding propolis, the numbers of damaged undifferentiated cells were decreased in testis and the shape of the goblet cells and inner and outer muscular layers in intestine were restored to the original state and the hepatocytes and interlobular veins were shown intact in liver, suggesting that propolis has a potential capacity to restore cell shapes or resist deformation of cell.

  20. Determination of metal balance shift induced in small fresh water fish by X-ray irradiation using PIXE analysis

    International Nuclear Information System (INIS)

    Yukawa, M.; Aoki, K.; Iso, H.; Kodama, K.; Imaseki, H.; Ishikawa, Y.

    2005-01-01

    In the environmental pollution studies, it is very important to detect not only pollutants but also changes induced in organisms in the environment with various environmental stresses such as heavy metal toxicity radiation and agricultural chemicals. In the latter, monitoring is carried out using biological indicators to find out the changes, which have wide spectra from visible like deformity of the body to invisible such as changes in some enzyme activities. Changes of the balance of essential elements could occur in organisms to deal with the stresses. If we detect an elemental balance shift, we may see the environmental pollution in its early stages. Moreover, in the actual environment, combined effects, additive or reductive with coexistent elements or other stresses, is an important subject for investigation. Therefore, measurement of many elements in the biological indicator's simultaneously and determination of the distribution in the organisms are useful in clarifying the action of pollutants at sublethal levels. A small fresh water fish, Medaka can be used as one of the biological-indicators for determination of water quality. In the National Institute of Radiological Sciences (NIRS), an inbred strain of Medaka Orizias laptipes was established and has been maintained for the research purposes. Since the genetic background of inbred animals is almost uniform, the individual deviation among animals is very small. This characteristic is very useful to investigate the physiological effects of environmental stresses. We have continued to investigate the balance shift of essential elements induced in the bodies of Medaka by several stresses. In this paper, elemental content in various organs of the X-ray irradiated fish determined by PIXE method are reported in comparison with that of the control fish to observe the effect of the X-rays. Body size of Medaka is about 3 cm long, and the internal organs are very small (about l mm on average). PIXE is the most

  1. X-ray photoelectron spectroscopy study of synchrotron radiation irradiation of a polytetrafluoroethylene surface

    CERN Document Server

    Haruyama, Y; Matsui, S; Ideta, T; Ishigaki, H

    2003-01-01

    The effect of synchrotron radiation (SR) irradiation of a polytetrafluoroethylene (PTFE) surface was investigated using X-ray photoelectron spectroscopy (XPS). After the SR irradiation, the relative intensity of the F ls peak to the C ls peak decreased markedly. The chemical composition ratio to the F atoms to C atoms was estimated to be 0.29. From the curve fitting analysis of C ls and F ls XPS spectra, the chemical components and their intensity ratio were determined. The reason for the chemical composition change by the SR irradiation was discussed. (author)

  2. X-ray irradiation of RC-MAP pre-stored for various numbers of days. Effect of X-ray irradiation on RC-MAP and reuse of RC-MAP after irradiation

    International Nuclear Information System (INIS)

    Yamada, Naotomo; Nagumo, Fumio; Kawasaki, Seiji; Matsuzaki, Miwako; Tadano, Jutaro

    1995-01-01

    X-ray irradiation is currently in wide use as a means of preventing post-transfusion graft-versus-host disease (PT-GVHD). In this study, we evaluated the effects of X-ray irradiation on RC-MAP pre-stored for various numbers of days, and assessed how long irradiated RC-MAP can be stored. RC-MAP was irradiated at a dosage of 15 Gy at 1, 7, 14, 21 or 28 days after blood collection. These specimens were referred to as group I, II, III, IV and V (X-ray-irradiated groups), respectively. Non-irradiated RC-MAP was used as the control. Results showed that plasma K concentration increased after X-ray irradiation. It is therefore advisable that RC-MAPs be used immediately in infants and in renal failure. However, to maximize the efficiency of blood product use, it seemed possible that groups I and II could be used within two weeks after irradiation, and group III within one week. On the basis of this increase in K concentration, however, groups IV and V plasma should be used immediately after irradiation. (author)

  3. Interest of the grazing X ray diffraction to study the evolution of materials under irradiation: behaviour of zirconia under irradiation

    International Nuclear Information System (INIS)

    Simeone, D.; Gosset, D.; Bechade, J.L.

    2001-01-01

    This document was written to show that grazing X ray diffraction may be a powerful tool to study irradiation damages induced by ion beams in materials. Taking advantage of an asymmetric geometry and a curved detector, it is possible to analyse accurately diffraction diagrams at low angles by taking into account the specific effects induced by the grazing incidence. The interest of grazing incidence is to control the penetration depth of X rays. Such possibility allows to separate effects induced by damages (displacement cascades) and the implantation peak (elastic deformation of the lattice due to the insertion of projectile ions in the matrix). A Rietveld analysis on grazing X ray diagrams shows clearly that displacement cascades induce a phase transition on irradiated zirconia. (authors)

  4. Controlling Botrytis elliptica Leaf Blight on Hybrid Lilies through the Application of Convergent Chemical X-ray Irradiation

    Directory of Open Access Journals (Sweden)

    Sung-Jun Hong

    2016-04-01

    Full Text Available X-ray irradiation with convergent chemicals such as nano-silver particles or sodium dichloroisocyanurate (NaDCC has been used to control leaf blight on cut lilies. The oriental hybrid lily cultivars Siberia, Le Reve, and Sorbonne were irradiated five times by 200 Gy of X-rays in 2014. In 2015, Siberia and Sorbonne were irradiated three times by 150 Gy of X-rays. After artificial infection with Botrytis elliptica on the leaves and petals of cut lilies, this study used convergent chemical X-ray irradiation of 200 Gy or 150 Gy. Leaf and petal blight was measured in terms of incidence and severity at 8 days after infection using total 552 cuttings. Results indicate that the treatments of X-ray irradiation and NaDCC in 2014 and 2015 slightly decreased the severity of petal blight on Siberia and Sorbonne. However, the results were not significant and severity did not decrease as NaDCC concentration increased. Vase-life was observed separately after X-ray irradiation of 270 cut lilies in 2014 and 108 cut lilies in 2015. Chlorophyll content was not affected by either 200 Gy or 150 Gy of X-rays. The number of days of fully opened flowers at Siberia of 150 Gy and Le Revu of 200 Gy increased by 1–2 days. In addition, the relative fresh weights of the X-rayed flowers were 10% drier than the non-irradiated controls. Overall, leaf blight control by X-ray was inferior to the control by gamma rays, and petal color was bleached in Sorbonne and Le Reve cvs. by 150 Gy of X-rays.

  5. An X-Ray facility to perform irradiation tests and TID studies on electronics and detectors

    CERN Document Server

    Brundu, Davide; Cadeddu, Sandro; Wyllie, Ken; Ciambrone, Paolo

    2018-01-01

    The X-Ray irradiation system of the LHCb group, installed in Cagliari, is presented; with a particular focus on the setup configuration and dose rate calibration. The system can be used to perform Total Ionizing Dose (TID) studies for detectors, readout and front-end electronics. It was already used to test the nSYNC chip, an ASIC for the readout of the LHCb upgraded muon system.

  6. Attempt at interpreting some optical absorption bands in X-ray irradiated fluorine

    International Nuclear Information System (INIS)

    Allain, Yves

    1959-01-01

    According to the results of one of our experiments, the 575 mμ absorption band of fluorine irradiated with X-Rays seams due to F - ion vacancies. Our goal has been to find a color centers model in fluorine colored in various conditions. Reprint of a paper published in Comptes rendus des seances de l'Academie des Sciences, t. 248, p. 2318-2320, sitting of Aril 20, 1959 [fr

  7. Two cases of fibrosarcoma occurring in the x-ray irradiated site

    International Nuclear Information System (INIS)

    Wakamatsu, Katsuo; Mochizuki, Masako.

    1975-01-01

    The histological examination was carried out on the following 2 cases: One case was a 46-year-old man with psoriasis vulgaris who received x-ray irradiation continually for about 10 years on the gluteal regions and the extensive sides of both elbows. An ulcer appeared on the irradiated site and about 2 weeks later a tumor appeared. The other case was a 77-year-old man with prurigo in the pudendal region. Although the dose and duration of irradiation are unknown, the tumors appeared in the irradiated site 6-7 years after the start of irradiation. The histological examination of these cases revealed the clinical findings of fibrosarcoma. In the review of literature, 8 cases of irradiation sarcoma in Japan were discussed. (Kanao, N.)

  8. X-ray dark-field imaging for detection of foreign bodies in food

    DEFF Research Database (Denmark)

    Nielsen, Mikkel Schou; Lauridsen, Torsten; Feidenhans'l, Robert Krarup

    2013-01-01

    Conventional X-ray transmission radiography has long been used for online detection of foreign bodies in food products relying on the absorption contrast between the foreign body and food product. In this paper, we present a novel approach for detection of organic foreign bodies such as paper...... and insects in two food products using X-ray dark-field imaging with a grating interferometer. The ability to detect the foreign bodies is quantified using a measure of the contrast-to-noise ratio....

  9. Measurement of body composition in cats using computed tomography and dual energy X-ray absorptiometry

    DEFF Research Database (Denmark)

    Buelund, Lene E; Nielsen, Dorte H; McEvoy, Fintan

    2011-01-01

    Dual energy X-ray absorptiometry (DEXA) is a reference method for assessing body composition but is seldom `accessible in veterinary settings. Computed tomography (CT) can provide similar body composition estimates and we propose that it can be used in body composition studies in animals. We...

  10. Solar X-Ray Irradiance Observations from the NOAA GOES Spacecraft: Accuracy vs Continuity

    Science.gov (United States)

    Viereck, R. A.; Machol, J. L.

    2017-12-01

    For 45 years, the solar X-Ray Sensors (XRS) on the GOES weather satellites have been making real-time measurements of the disk-integrated solar x-ray irradiance. These data have been remarkably consistent and contiguous and are the backbone of modern solar flare classification. When GOES 8 was launched in 1994, it observed 30% higher x-ray flux values compared to the earlier GOES. But no obvious cause of this offset was ever determined. For the sake of continuity, NOAA decided to adjust the GOES 8 data to match the old. We have been adjusting the XRS data on every GOES since (GOES 8-15). GOES 16 was launched in November of 2016 with a new XRS. This will be the first XRS that will have been fully calibrated with a primary calibration source so the values that it produces are presumed to be the most accurate yet. These new data show that our adjustment of the GOES 8 through 15 XRS data is not correct and that the true solar X-ray values are 30% higher than what has been reported for the last 45 years. In this presentation, we will show how the XRS sensors are characterized how the raw data are transformed into the science units that are presented to the public. We will present a plan on how to accurately present these new XRS values while maintaining continuity with the long record of XRS data.

  11. Mucosal pathology of an experimental otitis media with effusion after X-ray irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Ohashi, Y.; Nakai, Y.; Ikeoka, H.; Esaki, Y.; Koshimo, H.; Onoyama, Y.

    1987-07-01

    Ten guinea pigs were irradiated with 30 Gy of x-radiation. Five were killed on the eighth day after irradiation, and the remainder were killed at the sixteenth day after irradiation. At the time of death, examination was made of the ciliary activity and the fine structure of the middle ear mucosa. Serous effusion was found in each tympanic cavity of all animals. It was shown also that the guinea pig, when irradiated with 30 Gy of x-radiation, exhibits pathologic abnormalities similar to those in humans with otitis media with effusion: degeneration of cilia or ciliated cells and changes in the vascular system (capillary injury and increased capillary permeability). Functional examinations showed that x-ray irradiation has delayed effects on ciliary activity, and the effects are much greater at the sixteenth day than at the eighth day. We speculate that the accumulation of effusion can be, at least partially, a consequence of ciliary dysfunction. The induction of sterile effusion by the use of x-ray irradiation provides a unique animal model for chronic otitis media with effusion of the serous type.

  12. Scintillation properties and X-ray irradiation hardness of Ce3+-doped Gd2O3-based scintillation glass

    International Nuclear Information System (INIS)

    Liu, Liwan; Shao, Chongyun; Zhang, Yu; Liao, Xili; Yang, Qiuhong; Hu, Lili; Chen, Danping

    2016-01-01

    Ce 3+ -doped Gd 2 O 3 -based scintillation glasses are prepared within an air or CO atmosphere. The effects of fluorine, lutetium, barium, and the melting atmosphere on the optical properties, scintillation properties and irradiation hardness are studied. Absorption spectra, luminescence spectra under UV and X-ray excitation, and the X-ray radiation-induced spectra are presented. The results show that the density can be increased by doping with fluorine, lutetium and barium. The luminescence intensity decreases after X-ray irradiation. Because of charge transfer quenching, fluorine and lutetium enhance the UV-excited and X-ray excited luminescence intensity, but barium decreases. Moreover, fluorine and lutetium are advantageous to irradiation hardness while barium is not. In addition, a non-reducing atmosphere provides a higher irradiation hardness than a reducing atmosphere. Fluorine-doped glass is promising to enhance luminescence intensity, promote irradiation hardness, and increase the density.

  13. Mathematical modeling predicts enhanced growth of X-ray irradiated pigmented fungi.

    Directory of Open Access Journals (Sweden)

    Igor Shuryak

    Full Text Available Ionizing radiation is known for its cytotoxic and mutagenic properties. However, recent evidence suggests that chronic sub-lethal irradiation stimulates the growth of melanin-pigmented (melanized fungi, supporting the hypothesis that interactions between melanin and ionizing photons generate energy useful for fungal growth, and/or regulate growth-promoting genes. There are no quantitative models of how fungal proliferation is affected by ionizing photon energy, dose rate, and presence versus absence of melanin on the same genetic background. Here we present such a model, which we test using experimental data on melanin-modulated radiation-induced proliferation enhancement in the fungus Cryptococcus neoformans, exposed to two different peak energies (150 and 320 kVp over a wide range of X-ray dose rates. Our analysis demonstrates that radiation-induced proliferation enhancement in C. neoformans behaves as a binary "on/off" phenomenon, which is triggered by dose rates 5000 mGy/h. Proliferation enhancement of irradiated cells compared with unirradiated controls occurs at both X-ray peak energies, but its magnitude is modulated by X-ray peak energy and cell melanization. At dose rates <5000 mGy/h, both melanized and non-melanized cells exposed to 150 kVp X-rays, and non-melanized cells exposed to 320 kVp X-rays, all exhibit the same proliferation enhancement: on average, chronic irradiation stimulates each founder cell to produce 100 (95% CI: 83, 116 extra descendants over 48 hours. Interactions between melanin and 320 kVp X-rays result in a significant (2-tailed p-value = 4.8 × 10(-5 additional increase in the number of radiation-induced descendants per founder cell: by 55 (95% CI: 29, 81. These results show that both melanin-dependent and melanin-independent mechanisms are involved in radiation-induced fungal growth enhancement, and implicate direct and/or indirect interactions of melanin with high energy ionizing photons as an important pro

  14. New Solar Irradiance Measurements from the Miniature X-Ray Solar Spectrometer Cubesat

    Energy Technology Data Exchange (ETDEWEB)

    Woods, Thomas N.; Jones, Andrew; Kohnert, Richard; Mason, James Paul; Moore, Christopher S.; Palo, Scott; Rouleau, Colden [University of Colorado, Boulder, CO (United States); Caspi, Amir [Southwest Research Institute, Boulder, CO (United States); Chamberlin, Phillip C. [NASA Goddard Space Flight Center, Greenbelt, MD (United States); Solomon, Stanley C. [National Center for Atmospheric Research, Boulder, CO (United States); Machol, Janet; Viereck, Rodney [NOAA Space Weather Prediction Center, Boulder, CO (United States)

    2017-02-01

    The goal of the Miniature X-ray Solar Spectrometer ( MinXSS ) CubeSat is to explore the energy distribution of soft X-ray (SXR) emissions from the quiescent Sun, active regions, and during solar flares and to model the impact on Earth's ionosphere and thermosphere. The energy emitted in the SXR range (0.1–10 keV) can vary by more than a factor of 100, yet we have limited spectral measurements in the SXRs to accurately quantify the spectral dependence of this variability. The MinXSS primary science instrument is an Amptek, Inc. X123 X-ray spectrometer that has an energy range of 0.5–30 keV with a nominal 0.15 keV energy resolution. Two flight models have been built. The first, MinXSS -1, has been making science observations since 2016 June 9 and has observed numerous flares, including more than 40 C-class and 7 M-class flares. These SXR spectral measurements have advantages over broadband SXR observations, such as providing the capability to derive multiple-temperature components and elemental abundances of coronal plasma, improved irradiance accuracy, and higher resolution spectral irradiance as input to planetary ionosphere simulations. MinXSS spectra obtained during the M5.0 flare on 2016 July 23 highlight these advantages and indicate how the elemental abundance appears to change from primarily coronal to more photospheric during the flare. MinXSS -1 observations are compared to the Geostationary Operational Environmental Satellite ( GOES ) X-ray Sensor (XRS) measurements of SXR irradiance and estimated corona temperature. Additionally, a suggested improvement to the calibration of the GOES XRS data is presented.

  15. New Solar Irradiance Measurements from the Miniature X-Ray Solar Spectrometer CubeSat

    Science.gov (United States)

    Woods, Thomas N.; Caspi, Amir; Chamberlin, Phillip C.; Jones, Andrew; Kohnert, Richard; Mason, James Paul; Moore, Christopher S.; Palo, Scott; Rouleau, Colden; Solomon, Stanley C.; Machol, Janet; Viereck, Rodney

    2017-02-01

    The goal of the Miniature X-ray Solar Spectrometer (MinXSS) CubeSat is to explore the energy distribution of soft X-ray (SXR) emissions from the quiescent Sun, active regions, and during solar flares and to model the impact on Earth's ionosphere and thermosphere. The energy emitted in the SXR range (0.1-10 keV) can vary by more than a factor of 100, yet we have limited spectral measurements in the SXRs to accurately quantify the spectral dependence of this variability. The MinXSS primary science instrument is an Amptek, Inc. X123 X-ray spectrometer that has an energy range of 0.5-30 keV with a nominal 0.15 keV energy resolution. Two flight models have been built. The first, MinXSS-1, has been making science observations since 2016 June 9 and has observed numerous flares, including more than 40 C-class and 7 M-class flares. These SXR spectral measurements have advantages over broadband SXR observations, such as providing the capability to derive multiple-temperature components and elemental abundances of coronal plasma, improved irradiance accuracy, and higher resolution spectral irradiance as input to planetary ionosphere simulations. MinXSS spectra obtained during the M5.0 flare on 2016 July 23 highlight these advantages and indicate how the elemental abundance appears to change from primarily coronal to more photospheric during the flare. MinXSS-1 observations are compared to the Geostationary Operational Environmental Satellite (GOES) X-ray Sensor (XRS) measurements of SXR irradiance and estimated corona temperature. Additionally, a suggested improvement to the calibration of the GOES XRS data is presented.

  16. DNA Damage Induction and Repair Evaluated in Human Lymphocytes Irradiated with X-Rays an Neutrons

    International Nuclear Information System (INIS)

    Niedzwiedz, W.; Cebulska-Wasilewska, A.

    2000-12-01

    The objective of this study was to evaluate the kinetic of the DNA damage induction and their subsequent repair in human lymphocytes exposed to various types of radiation. PBLs cells were isolated from the whole blood of two young healthy male subjects and one skin cancer patient, and than exposed to various doses of low LET X-rays and high LET neutrons from 252 Cf source. To evaluate the DNA damage we have applied the single cell get electrophoresis technique (SCGE) also known as the comet assay. In order to estimate the repair efficiency, cells, which had been irradiated with a certain dose, were incubated at 37 o C for various periods of time (0 to 60 min). The kinetic of DNA damage recovery was investigated by an estimation of residual DNA damage persisted at cells after various times of post-irradiation incubation (5, 10, 15, 30 and 60 min). We observed an increase of the DNA damage (reported as a Tail DNA and Tail moment parameters) in linear and linear-quadratic manner, with increasing doses of X-rays and 252 Cf neutrons, respectively. Moreover, for skin cancer patient (Code 3) at whole studied dose ranges the higher level of the DNA damage was observed comparing to health subjects (Code 1 and 2), however statistically insignificant (for Tail DNA p=0.056; for Tail moment p=0.065). In case of the efficiency of the DNA damage repair it was observed that after 1 h of post-irradiation incubation the DNA damage induced with both, neutrons and X-rays had been significantly reduced (from 65% to 100 %). Furthermore, in case of skin cancer patient we observed lover repair efficiency of X-rays induced DNA damage. After irradiation with neutrons within first 30 min, the Tail DNA and Tail moment decreased of about 50%. One hour after irradiation, almost 70% of residual and new formed DNA damage was still observed. In this case, the level of unrepaired DNA damage may represent the fraction of the double strand breaks as well as more complex DNA damage (i.e.-DNA or DNA

  17. Dosimetric characteristics of ultraviolet and x-ray-irradiated KBr:Eu{sup 2+} thermoluminescence crystals

    Energy Technology Data Exchange (ETDEWEB)

    Melendrez, R.; Perez-Salas, R. [Programa de Posgrado en Fisica de Materiales, Centro de Investigacion, Cientifica y de Educacion Superior de Ensenada, Apartado Postal 2681, Ensenada, Baja California, 22800 (Mexico); Aceves, R.; Piters, T.M.; Barboza-Flores, M. [Centro de Investigacion en Fisica, Universidad de Sonora, Apartado Postal 5-088, Hermosillo, Sonora, 83190 (Mexico)

    1996-08-01

    Thermoluminescence (TL) characteristics of KBr:Eu{sup 2+} (150 ppm) previously exposed to ultraviolet (UV) light (200{endash}300 nm) and x-ray radiation at room temperature have been determined. The TL glow curve of UV-irradiated samples is composed of six peaks located at 337, 384, 402, 435, 475, and 510 K. The TL glow curves of x-irradiated samples show mainly a TL peak around 384 K. The TL intensities of UV-irradiated (402 and 510 K glow peaks) and x-irradiated specimens present a linear dependence as a function of radiation dose as well as fading stability 300 s after irradiation. These results further enhance the possibilities of using europium-doped materials in nonionizing (actinic region) and ionizing radiation detection and dosimetry applications. {copyright} {ital 1996 American Institute of Physics.}

  18. Analysis of electron-irradiated poly-ether ether ketone by X-ray photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Oyabu, Matashige; Kobayashi, Yoshinori; Seguchi, Tadao; Sasuga, Tsuneo; Kudoh, Hisaaki.

    1995-01-01

    Organic polymers used in atomic power plants or space are damaged by ionizing irradiation. Radicals produced by irradiation cause oxidation, chain scission and crosslinking, all of which lead to degradation of the material. In this paper, the surface of electron-irradiated poly-ether ether ketone (PEEK) was studied by X-ray photoelectron spectroscopy (XPS). The irradiation in air was found to oxidize the PEEK surface producing carboxyl groups, the content of which dependant on the dose. Carboxyl groups were not produced in helium gas. Quantitative spectral analysis indicated that the aromatic structure might be decomposed. Some comparison was made between the semicrystalline and amorphous samples. The oxygen content resulting from irradiation, of semicrystalline PEEK increased more than that of amorphous PEEK. (author)

  19. Dosimetric characteristics of ultraviolet and x-ray-irradiated KBr:Eu2+ thermoluminescence crystals

    International Nuclear Information System (INIS)

    Melendrez, R.; Perez-Salas, R.; Aceves, R.; Piters, T.M.; Barboza-Flores, M.

    1996-01-01

    Thermoluminescence (TL) characteristics of KBr:Eu 2+ (150 ppm) previously exposed to ultraviolet (UV) light (200 endash 300 nm) and x-ray radiation at room temperature have been determined. The TL glow curve of UV-irradiated samples is composed of six peaks located at 337, 384, 402, 435, 475, and 510 K. The TL glow curves of x-irradiated samples show mainly a TL peak around 384 K. The TL intensities of UV-irradiated (402 and 510 K glow peaks) and x-irradiated specimens present a linear dependence as a function of radiation dose as well as fading stability 300 s after irradiation. These results further enhance the possibilities of using europium-doped materials in nonionizing (actinic region) and ionizing radiation detection and dosimetry applications. copyright 1996 American Institute of Physics

  20. Degradation of DNA in Haemophilus influenzae cells after x-ray irradiation. I. Experimental results

    International Nuclear Information System (INIS)

    Randolph, M.L.; Setlow, J.K.

    1975-01-01

    Sequential measurements of DNA in Haemophilus influenzae cells after x-ray irradiation show rapid initial degradation of DNA followed by a plateau after about 40 min at normal growth conditions. Both the initial rate and final amount of degradation increase with radiation exposure. Degradation is somewhat greater in stationary-phase than in log-phase cells, but colony-forming ability (CFA) is independent of cell stage. Distributions of single-strand lengths of DNA in unirradiated or irradiated cases, as measured by alkaline sucrose gradient techniques, are neither monodispersive nor random, and possible causes for nonrandomness are discussed

  1. Age-related effects of X-ray irradiation on mouse hippocampus

    DEFF Research Database (Denmark)

    Casciati, Arianna; Dobos, Katalin; Antonelli, Francesca

    2016-01-01

    and molecular alterations induced by cranial X-ray exposure to low/moderate doses (0.1 and 2 Gy) in the hippocampus of mice irradiated at the postnatal ages of day 10 or week 10, as well as the dependency of these phenomena on age at irradiation. To this aim, changes in the cellular composition of the dentate...... gyrus, mitochondrial functionality, proteomic profile in the hippocampus, as well as cognitive performance were evaluated by a multidisciplinary approach. Our results suggest the induction of specific alterations in hippocampal neurogenesis, microvascular density and mitochondrial functions, depending...

  2. The effect of X-ray irradiation on the time dependent behavior of accretion disks with stochastic perturbations.

    Science.gov (United States)

    Maqbool, Bari; Misra, Ranjeev; Iqbal, Naseer

    The UV emission from X-ray binaries, may arise from the outer accretion disk. The structure of the outer disk may be altered due to the presence of X-ray irradiation and we discuss the physical regimes where this may occur and point out certain X-ray binaries where this effect may be important. The long term X-ray variability of these sources is believed to be due stochastic fluctuations in the outer disk, which propagate inwards giving rise to accretion rate variation in the X-ray producing inner regions. Our motivation is to understand the effect of X-ray irradiation in such a scenario. To this end, a time dependent hydrodynamical framework with X-ray irradiation needs to be set up, such that the effect of fluctuations in the outer disk can be studied. Following earlier works, we solve for the steady state accretion disk structure taking into account irradiation. To understand the qualitative behavior, we adopt simplistic assumptions that the disk is fully ionized and it is not warped. We then proceeded to develop a time dependent hydrodynamic code, which in the absence of perturbations is numerically stable. A sinusoidal perturbation was introduced at different radii, and its effect on the mass accretion rate in the inner disk was computed. The code was carefully studied to verify that the results are invariant to the numerical time steps and radial bins used. While we didn't find any oscillatory or limit cycle behavior due to the X-ray irradiation feedback, our results show irradiation enhances the X-ray variability at time-scales corresponding to the viscous time-scales of the irradiated disk.

  3. The effect of X-ray irradiation on the time-dependent behaviour of accretion discs with stochastic perturbations

    Science.gov (United States)

    Maqbool, Bari; Misra, Ranjeev; Iqbal, Naseer; Ahmad, Naveel

    2015-04-01

    The UV emission from X-ray binaries, is more likely to be produced by reprocessing of X-rays by the outer regions of an accretion disc. The structure of the outer disc may be altered due to the presence of X-ray irradiation and we discuss the physical regimes where this may occur and point out certain X-ray binaries where this effect may be important. The long-term X-ray variability of these sources is believed to be due to stochastic fluctuations in the outer disc, which propagate inwards giving rise to accretion rate variation in the X-ray-producing inner regions. The X-ray variability will induce structural variations in the outer disc which in turn may affect the inner accretion rate. To understand the qualitative behaviour of the disc in such a scenario, we adopt simplistic assumptions that the disc is fully ionized and is not warped. We develop and use a time-dependent global hydrodynamical code to study the effect of a sinusoidal accretion rate perturbation introduced at a specific radius. The response of the disc, especially the inner accretion rate, to such perturbations at different radii and with different time periods is shown. While we did not find any oscillatory or limit cycle behaviour, our results show that irradiation enhances the X-ray variability at time-scales corresponding to the viscous time-scales of the irradiated disc.

  4. Physiological parameters in tomato seedlings ( Solanum lycopersicum L., obtained from X-rays irradiated seeds

    Directory of Open Access Journals (Sweden)

    Alexander Álvarez Fonseca

    2014-04-01

    Full Text Available A study was carried out to determine the effect of low doses of X-rays on some physiological indicators of tomato seedlings FA-180, in greenhouse cultivation during the months of July-August 2010. The treatment was carried out in a source of low-power irradiation (11.47 Gy / min in the morning hours at doses of 5, 10 and 20 Gy with a Phillips x-ray machine; model RT-100, with a duty cycle of 30 kV and 10 mA. The evaluated indicators were seedling height, root length, stem diameter, fresh stem weight, dry stem mass, fresh root weight and dry root mass. Results indicated a significant stimulation (p d” 0.05, for indicators as seedling height, root length, stem diameter, fresh stem mass, dry stem mass and fresh root mass related to the control, which corroborates the stimulating effect of this treatment on seedling growth

  5. Setup for in situ x-ray diffraction study of swift heavy ion irradiated materials.

    Science.gov (United States)

    Kulriya, P K; Singh, F; Tripathi, A; Ahuja, R; Kothari, A; Dutt, R N; Mishra, Y K; Kumar, Amit; Avasthi, D K

    2007-11-01

    An in situ x-ray diffraction (XRD) setup is designed and installed in the materials science beam line of the Pelletron accelerator at the Inter-University Accelerator Centre for in situ studies of phase change in swift heavy ion irradiated materials. A high vacuum chamber with suitable windows for incident and diffracted X-rays is integrated with the goniometer and the beamline. Indigenously made liquid nitrogen (LN2) temperature sample cooling unit is installed. The snapshots of growth of particles with fluence of 90 MeV Ni ions were recorded using in situ XRD experiment, illustrating the potential of this in situ facility. A thin film of C60 was used to test the sample cooling unit. It shows that the phase of the C60 film transforms from a cubic lattice (at room temperature) to a fcc lattice at around T=255 K.

  6. X-ray studies of irradiation induced dislocation loops in metals

    International Nuclear Information System (INIS)

    Larson, B.C.

    1975-01-01

    Theoretical and experimental progress has resulted in the increased use of x-rays for the study of defects and defect clusters in crystals. An outline of the theoretical framework associated with Huang, Stokes-Wilson and integral diffuse scattering from dislocation loops is presented, and an account of recent experiments on radiation induced loops is given. These studies include low temperature, ambient temperature, and elevated temperature irradiations of metals with electrons, neutrons, and accelerated ions, and pertain to the study of the thermal annealing characteristics as well as the as-produced damage structure. The information obtained by x-rays as to the type, size and concentrations of dislocation loops is contrasted with existing electron microscopy, electrical resistivity, and lattice parameter data in order to establish correlations and identify areas of disagreement

  7. Charge yield for cobalt-60 and 10-keV x-ray irradiations of MOS devices

    International Nuclear Information System (INIS)

    Shaneyfelt, M.R.; Fleetwood, D.M.; Schwank, J.R.; Hughes, K.L.

    1991-01-01

    In this paper the radiation response of MOS devices exposed to 60 Co and low-energy (∼10 keV) x-ray irradiation is evaluated as a function of electric field during exposure. Improved charge yield estimates are obtained for 60 Co irradiations at fields below 1 MV/cm by matching voltage shifts due to oxide-trap and interface-trap charge to an E -0.55 electric field dependence. Combining these improved charge yield estimates and calculated dose enhancement factors, the relative response of x-ray to 60 Co irradiations is accurately predicted for oxide electric fields from 0.03 MV/cm to 5.0 MV/cm. The ability to predict the relative response of x-ray to 60 Co irradiations should speed acceptance of x-ray testers as a hardness assurance tool

  8. Single Event Gate Rupture in 130-nm CMOS Transistor Arrays Subjected to X-Ray Irradiation

    CERN Document Server

    Silvestri, M; Gerardin, Simone; Faccio, Federico; Paccagnella, Alessandro

    2010-01-01

    We present new experimental results on heavy ion-induced gate rupture on deep submicron CMOS transistor arrays. Through the use of dedicated test structures, composed by a large number of 130-nm MOSFETs connected in parallel, we show the response to heavy ion irradiation under high stress voltages of devices previously irradiated with X-rays. We found only a slight impact on gate rupture critical voltage at a LET of 32 MeV cm(2) mg(-1) for devices previously irradiated up to 3 Mrad(SiO2), and practically no change for 100 Mrad(SiO2) irradiation, dose of interest for the future super large hadron collider (SLHC).

  9. Effects of x-ray irradiation on AC characteristics of pyrolyzed polyacrylonitrile semiconductor

    International Nuclear Information System (INIS)

    Ito, Seiichi; Matsumura, Yasuo; Koshita, Itsuro; Imazaki, Kazuo.

    1975-01-01

    Polyacrylonitrile was turned into two kinds of semiconductors by different processes of pyrolysis up to 500 0 C. Then they were irradiated with X-rays in the air, and variations of their impedance after cessation of irradiation were measured. The variation of impedance is closely connected with scission and recombination of the conjugated double bond chain, with enlargement and narrowing of space between two chains and also with generation and recombination of ions and electrons. And these variations of structure cause a variation of resistance at any place and that of capacitance in the neighborhood of the electrode. Two kinds of processes of impedance variation appear after cessation of irradiation; one of them disappears within about 30 minutes, and the other persists for more than 2 hours. And both processes occur extensively at the part where the chemical bond is imperfectly conjugated. Generally speaking, it seems that the main reaction which is caused by X-rays irradiation is the scission of the conjugated double bond. (auth.)

  10. Time dependent spectrum of an X-ray irradiated accretion disc with stochastic perturbations

    Science.gov (United States)

    Maqbool, Bari; Wani, Naveel; Iqbal, Naseer; Misra, Ranjeev

    2016-07-01

    The X-rays emitted by the inner regions of the accretion disk induce structural changes in the outer regions of the disk. We study here how the effective temperature and hence the corresponding spectrum of the disk is altered by stochastic perturbations in the outer regions and thereby try to study the long term variability which has been observed in some X-ray binaries. We use a time dependent global hydrodynamic code to study the variations in the effective temperature of the disk in response to sinusoidal accretion rate perturbations introduced at different radii and with different time periods. To quantify the results, we calculate the root mean square effective temperature at different radii and the root mean square flux at different frequencies. From our calculations of the time-lags in accretion rate, effective temperature and the different frequencies, we find that the time-lags in presence of X-ray irradiation is significantly smaller than the expected viscous time-scale.

  11. Pupal x-ray irradiation influences protein expression in adults of the oriental fruit fly, Bactrocera dorsalis

    Science.gov (United States)

    We did protein analysis using 1-12-d-old adults from irradiated and non-irradiated oriental fruit fly pupae. We found that exposing pupae to x-ray irradiation impacted expression of 26 proteins in adult females and 30 proteins in adult males. There were 7 proteins (Glyceraldehyde-3-phosphate dehyd...

  12. Experimentally induced intestinal metaplasia in Wistar rats by x-ray irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, H.

    1978-11-01

    The gastric region of 5-week-old female Wistar rats was irradiated daily with 500 rad of x-ray up to a total of six times. Goblet cells and marker enzymes of the small intestine, such as lactase, trehalase, and maltase, appeared in the pyloric region of the glandular stomach of the rats from the 1st week after final irradiation. Intestinal type crypt without Paneth cells was observed from the 8th week. Sucrase activity appeared from the 26th week. Intestinal metaplasia with Paneth cells appeared from the 71st week. The number of goblet cells, intestinal type crypts, and Paneth cells increased with age. Gastric adenocarcinoma did not develop after irradiation.

  13. Response of mesenchymal stem cells in mice to 3.5 Gy X-ray irradiation

    International Nuclear Information System (INIS)

    Su Wenxia; Liu Huimin; Chen Yonghong; Zeng Wen; Liu Wenli; Sun Hanying

    2011-01-01

    Objective: To investigate the response of mesenchymal stem cells in mice to medium-dose X-ray irradiation in vitro. Methods: The mouse mesenchymal stem cell line C3H10T1/2 was submitted to 3.5 Gy X-ray irradiation. Hoechst33258 staining of adherent cells and Annexin V-FITC staining and flow cytometry analysis of suspension cells were performed respectively to assess cellular apoptosis at 3, 6, 12, 24, 48, 72 h and 1 week after irradiation. SA-β-gal staining was performed to analyze the cellular senescence at 24, 48, 72 h and 1 week after irradiation. The mRNA level of both Fas with its ligand FasL and p53 with its downstream target p21 WAF1 were measured by Real-Time PCR analysis. The expression of Fas protein was determined by immunofluorescence staining. Results: An increased apoptosis was observed at 3 h after irradiation with apoptosis rate 11.72% ± 1.61% (t=9.01, P<0.01), the apoptosis rate reached the peak level at 12 h 20.52% ± 1.96% (t=16.27, P<0.01), and then declined progressively to normal level at 48 h 4.93% ±0.46% (t=2.26, P>0.05). The SA-β-gal positive rate of post-radiation cells at 72 h was 53.33% ± 5.62%, significantly higher than that of normal control 3.24% ± 0.39% (t=17.77, P<0.01). The level of Fas, FasL mRNA was found to be elevated 3 h after irradiation with a peak at 12 h, and no differences were found l week later. The level of Fas protein was observed to reach the peak at 12 h after irradiation. The occurrence of peak level of Fas/FasL mRNA and protein was consistent with that of apoptosis of C3H10T1/2 cell. A transient up-regulation of p53, p21 WAF1 mRNA expression was found at 12 h after irradiation followed by a significant increase later at 72 h after irradiation. The occurrence of the two peaks of p53, p21 WAF1 mRNA expression were coincident with that of cellular apoptosis and senescence, respectively. The levels of p53, p21 WAF1 mRNA in senescence group were significantly higher than those of apoptosis group (t=17.85, 13

  14. Diffuse X-ray scattering from neutron-irradiated silicon doped with boron

    International Nuclear Information System (INIS)

    Mayer, W.; Grasse, D.; Peisl, J.

    1985-01-01

    The diffuse X-ray scattering and lattice parameter change of silicon crystals heavily doped with boron after electron and neutron irradiation are measured. From a comparison of unirradiated and electron-irradiated samples the volume change is determined of substitutional boron Q/sub B/ = -(2.2 +- 0.2) x 10 -2 nm 3 and of boron with a trapped interstitial Q/sub BI/ = (0 +- 0.5) x 10 -2 nm 3 . During neutron irradiation of the doped samples each boron stabilizes an additional Frenkel pair by trapping of the interstitial. The concentration of the untrapped interstitials remains the same as in the undoped sample, but the nucleation of interstitial clusters is enhanced thus reducing the cluster size to 93% of the value of undoped samples. (author)

  15. An x-ray image guidance system for small animal stereotactic irradiation

    Science.gov (United States)

    Song, K. H.; Pidikiti, R.; Stojadinovic, S.; Speiser, M.; Seliounine, S.; Saha, D.; Solberg, T. D.

    2010-12-01

    An x-ray image-guided small animal stereotactic irradiator was developed and characterized to enable tumor visualization and accurate target localization for small field, high dose irradiation. The system utilizes a custom collimation system, a motorized positioning system (x, y, θ), a digital imaging panel and operating software, and is integrated with a commercial x-ray unit. The essential characteristics of the irradiator include small radiation fields (1-10 mm), high dose rate (>10 Gy min-1) and submillimeter target localization. The software enables computer-controlled image acquisition, stage motion and target localization providing simple and precise automated target localization. The imaging panel was characterized in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and spatial resolution. Overall localization accuracy and precision were assessed. SNR, CNR and spatial resolution are 24 dB, 21 dB and 2.8 lp mm-1, respectively, and localization accuracy is approximately 65 µm with 6 µm precision. With the aid of image guidance, system performance was subsequently used to evaluate radiation response in a rat orthotopic lung tumor effectively sparing normal tissues and in a mouse normal lung. The capabilities of 3D treatment and cone-beam computed tomography are presented for 3D localization and delivery as a work in progress.

  16. Neutron and X-ray irradiation of silicon based Mach-Zehnder modulators

    Science.gov (United States)

    El Nasr-Storey, S. S.; Détraz, S.; Olanterä, L.; Sigaud, C.; Soós, C.; Pezzullo, G.; Troska, J.; Vasey, F.; Zeiler, Marcel

    2015-03-01

    We report on our recent investigation into the potential for using silicon-based Mach-Zehnder modulators in the harshest radiation environments of the High-Luminosity LHC. The effect of ionizing and non-ionizing radiation on the performance of the devices have been investigated using the 20 MeV neutron beam line at the Cyclotron Resource Centre in Louvain-La-Neuve and the X-ray irradiation facility in the CERN PH department. The devices were exposed to a total fluence and ionizing dose of 1.2×1015 n cm-2 and 1.3 MGy respectively.

  17. Measurements of laser generated soft X-ray emission from irradiated gold foils

    Energy Technology Data Exchange (ETDEWEB)

    Davis, J. S.; Keiter, P. A.; Klein, S. R.; Drake, R. P.; Shvarts, D. [University of Michigan, 2455 Hayward St., Ann Arbor, Michigan 48109 (United States); Frank, Y.; Raicher, E.; Fraenkel, M. [Soreq Nuclear Research Center, Yavne (Israel)

    2016-11-15

    Soft x-ray emission from laser irradiated gold foils was measured at the Omega-60 laser system using the Dante photodiode array. The foils were heated with 2 kJ, 6 ns laser pulses and foil thicknesses were varied between 0.5, 1.0, and 2.0 μm. Initial Dante analysis indicates peak emission temperatures of roughly 100 eV and 80 eV for the 0.5 μm and 1.0 μm thick foils, respectively, with little measurable emission from the 2.0 μm foils.

  18. Synchrotron X-ray Microdiffraction Analysis of Proton Irradiated Polycrystalline Diamond Films

    Science.gov (United States)

    Newton, R. I.; Davidson, J. L.; Ice, G. E.; Liu, W.

    2004-01-01

    X-ray microdiffraction is a non-destructive technique that allows for depth-resolved, strain measurements with sub-micron spatial resolution. These capabilities make this technique promising for understanding the mechanical properties of MicroElectroMechanical Systems (MEMS). This investigation examined the local strain induced by irradiating a polycrystalline diamond thin film with a dose of 2x10(exp 17) H(+)per square centimeter protons. Preliminary results indicate that a measurable strain, on the order of 10(exp -3), was introduced into the film near the End of Range (EOR) region of the protons.

  19. X-ray topographic investigation of the deformation field around spots irradiated by FLASH single pulses

    Czech Academy of Sciences Publication Activity Database

    Wierzchowski, W.; Wieteska, K.; Balcer, T.; Klinger, D.; Sobierajski, R.; Zymierska, D.; Chalupský, Jaromír; Hájková, Věra; Burian, Tomáš; Gleeson, A.J.; Juha, Libor; Tiedtke, K.; Toleikis, S.; Vyšín, Luděk; Wabnitz, H.; Gaudin, J.

    2011-01-01

    Roč. 80, č. 10 (2011), s. 1036-1040 ISSN 0969-806X R&D Projects: GA AV ČR KAN300100702; GA MŠk LC510; GA ČR(CZ) GAP108/11/1312; GA MŠk(CZ) LC528; GA MŠk LA08024; GA AV ČR IAAX00100903; GA MŠk(CZ) ME10046 Institutional research plan: CEZ:AV0Z10100523 Keywords : silicon * FLASH irradiation * x-ray topography * deformation fields Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.227, year: 2011

  20. Validity of dual X-ray absorptiometry scanning for determination of body composition in IDDM patients

    DEFF Research Database (Denmark)

    Rosenfalck, A M; Almdal, T; Gotfredsen, A

    1995-01-01

    Data on body composition in patients with insulin-dependent diabetes mellitus (IDDM) are scarce. Dual X-ray absorptiometry (DXA) scanning has proved useful for this purpose in other groups of patients. We tested the validity of the DXA scanner for the determination of fat-free mass (FFM) and fat ...

  1. Influence of X-ray irradiation on the mandible of ovariectomized rats

    International Nuclear Information System (INIS)

    Ikoma, Kazuyuki; Iwata, Hiroshi; Yosue, Takashi

    2004-01-01

    The aim of the present study was to investigate the influence of irradiation on the mandible of ovariectomized (OVX) rats. Female rats were subject to OVX or a sham operation (SHAM) at the age of 14 weeks. Ten Gy doses of X-ray were applied to the mandibles twelve weeks after the operation. The experimental animals were divided into four groups: the OVX non-irradiation group, the OVX irradiation group, SHAM non-irradiation group and SHAM irradiation group. Four, eight and twelve weeks after irradiation, the animals were sacrificed and the mandibles removed. The mandibles were investigated using μCT and pQCT, and from the images obtained, the rate of mineralized tissue in the bone as well as the bone mineral content (BMC) were evaluated. The rate of mineralized tissue in the bone as determined from the images of μCT was significantly (P<0.05) lower in the OVX non-irradiation group than in the SHAM non-irradiation group at four weeks after irradiation. Similarly, the rate in the OVX irradiation group was lower than that in the SHAM irradiation group at twelve weeks after irradiation. In both the SHAM and OVX groups, there was no difference between the non-irradiation and irradiation groups. From the pQCT images, the change in the BMC in the cortical bone was negligible when the BMC was measured in the mandibles. In the OVX non-irradiation group, the trabecular BMC of the mandibles was significantly lower than that in the SHAM non-irradiation group at four and twelve weeks after irradiation. The trabecular BMC of the mandibles in the SHAM and OVX irradiation groups were significantly lower than that of the SHAM and OVX non-irradiation groups respectively throughout the experimental period. In the rate of mineralized tissue in the mandibles, the influence of OVX was recognized, but the influence of irradiation was not. On the other hand, the BMC in the cortical bone was not significant through out the experiment. The influence of irradiation on the OVX group was

  2. Biological X-ray irradiator characterization for use with small animals and cells

    Directory of Open Access Journals (Sweden)

    A. Colello Bruno

    Full Text Available This study presents the characterization of an X-ray irradiator through dosimetric tests, which confirms the actual dose rate that small animals and cells will be exposed to during radiobiological experiments. We evaluated the linearity, consistency, repeatability, and dose distribution in the positions in which the animals or cells are placed during irradiation. In addition, we evaluated the performance of the X-ray tube (voltage and tube operating current, the radiometric survey (leakage radiation and safety devices. The irradiator default setting was established as 160 kV and 25 mA. Tests showed that the dose rate was linear overtime (R2=1 and remained stable for long (constant and short (repeatability intervals between readings. The mean dose rate inside the animal cages was 1.27±0.06 Gy/min with a uniform beam of 95.40% (above the minimum threshold guaranteed by the manufacturer. The mean dose rate inside the cell plates was 0.92±0.19 Gy/min. The dose rate dependence with tube voltage and current presented a quadratic and linear relationship, respectively. There was no observed mechanical failure during evaluation of the irradiator safety devices and the radiometric survey obtained a maximum ambient equivalent dose rate of 0.26 mSv/h, which exempts it from the radiological protection requirements of the International Atomic Energy Agency. The irradiator characterization enables us to perform radiobiological experiments, and assists or even replaces traditional therapy equipment (e.g., linear accelerators for cells and small animal irradiation, especially in early research stages.

  3. Image combination enhancement method for X-ray compton back-scattering security inspection body scanner

    International Nuclear Information System (INIS)

    Wang Huaiying; Zhang Yujin; Yang Lirui; Li Dong

    2011-01-01

    As for X-ray Compton Back-Scattering (CBS) body scanner, image clearness is very important for the performance of detecting the contraband hidden on the body. A new image combination enhancement method is provided based on characteristics of CBS body images and points of human vision. After processed by this method, the CBS image will be obviously improved with clear levels, distinct outline and uniform background. (authors)

  4. Effects of X-ray irradiation to genetic transformation of Eruca sativa Mill mediated by agrobacterium rhizogenes

    International Nuclear Information System (INIS)

    Wu Zhenhua; Zhang Hong; Liu Bin; Li Ning; Niu Bingtao; Wang Genxuan; Li Sha; Sun Peng

    2008-01-01

    To investigate the effects of X-ray irradiation to the hairy root induction of Eruca sativa Mill, and to provide basic experimental data for concerted reaction of irradiation to the Genetic transformation technology. The aseptic cotyledons of Eruca sativa Mill were jointly treated with the X-ray at dose of 5, 10, 15, 20 Gy respectively and the different infected time, then the influence of explant age, pre-culturing time, dose of X-ray and infected time were studied. Furthermore, the hairy roots were testified in molecular level by the polymerase chain reaction(PCR). The irradiation of X-ray at dose of 15 Gy can improve the frequency of Eruca sativa Mill hairy root induction in a dose-dependent manner. Moreover, the transformation frequency in pre-infection plus irradiation group is higher than that in pre-irradiation plus infection group at the same irradiation dose. In addition, the PCR analysis also demonstrated that rolB gene of T-DNA from Ri plasmid had been integrated into the genome of the transformed roots. The irradiation of X-ray has some positive effects on the hairy root induction of Eruca sativa Mill, and the optimal revulsive dose is 15 Gy ora little bit more. (authors)

  5. CubeX: The CubeSAT X-ray Telescope for Elemental Abundance Mapping of Airless Bodies and X-ray Pulsar Navigation

    Science.gov (United States)

    Nittler, L. R.; Hong, J.; Kenter, A.; Romaine, S.; Allen, B.; Kraft, R.; Masterson, R.; Elvis, M.; Gendreau, K.; Crawford, I.; Binzel, R.; Boynton, W. V.; Grindlay, J.; Ramsey, B.

    2017-12-01

    The surface elemental composition of a planetary body provides crucial information about its origin, geological evolution, and surface processing, all of which can in turn provide information about solar system evolution as a whole. Remote sensing X-ray fluorescence (XRF) spectroscopy has been used successfully to probe the major-element compositions of airless bodies in the inner solar system, including the Moon, near-Earth asteroids, and Mercury. The CubeSAT X-ray Telescope (CubeX) is a concept for a 6U planetary X-ray telescope (36U with S/C), which utilizes Miniature Wolter-I X-ray optics (MiXO), monolithic CMOS and SDD X-ray sensors for the focal plane, and a Solar X-ray Monitor (heritage from the REXIS XRF instrument on NASA's OSIRIS-REx mission). CubeX will map the surface elemental composition of diverse airless bodies by spectral measurement of XRF excited by solar X-rays. The lightweight ( 1 kg) MiXO optics provide sub-arcminute resolution with low background, while the inherently rad-hard CMOS detectors provide improved spectral resolution ( 150 eV) at 0 °C. CubeX will also demonstrate X-ray pulsar timing based deep space navigation (XNAV). Successful XNAV will enable autonomous deep navigation with little to no support from the Deep Space Network, hence lowering the operation cost for many more planetary missions. Recently selected by NASA Planetary Science Deep Space SmallSat Studies, the first CubeX concept, designed to rideshare to the Moon as a secondary spacecraft on a primary mission, is under study in collaboration with the Mission Design Center at NASA Ames Research Center. From high altitude ( 6,000 km) frozen polar circular orbits, CubeX will study > 8 regions ( 110 km) of geological interest on the Moon over one year to produce a high resolution ( 2-3 km) elemental abundance map of each region. The novel focal plane design of CubeX also allows us to evaluate the performance of absolute navigation by sequential observations of several

  6. Degradation and crosslinking of perfluoroalkyl polyethers under X-ray irradiation in ultrahigh vacuum

    Science.gov (United States)

    Mori, Shigeyuki; Morales, Wilfredo

    1989-01-01

    Degradation of three types of commercially available perfluoroalkyl polyethers (PFPE)-Demnum S200, Fomblin Z25, and Krytox 16256-by X-ray irradiation was studied by using X-ray photoemission spectroscopy (XPS) and a mass spectrometer under ultra-high-vacuum conditions. The carbons in the polymers were characterized by chemical shifts of Cls binding energies. Gaseous products containing COF2 and low-molecular-weight fluorocarbons were formed. From Fomblin Z25, which has acetal linkages (-OCF2O-), a large quantity of COF2 gas was evolved. Liquid products became tacky after a long irradiation time, and some did not dissolve in Freon. High-pressure liquid chromatography (HPLC) showed that molecular weight distribution became broader and that higher molecular weight polymers were formed from Demnum and Krytox. We concluded from these results that degradation and cross-linking took place simultaneously. Demnum crosslinked more easily than the other fluids. The time dependence of both XPS spectra of Cls and mass spectra showed that C-O-bonded carbons in PFPE'S were removed faster than other carbons. There was no substrate effect on the degradation reaction because the first-order rate constants calculated from the change of gaseous products were similar when stainless steel (440C) and gold-coated surfaces were used. Metal fluorides were formed on stainless steel during the reaction. A mechanism for the degradation of PFPE'S is discussed on the basis of their molecular structures.

  7. X-ray irradiation activates K+ channels via H2O2 signaling.

    Science.gov (United States)

    Gibhardt, Christine S; Roth, Bastian; Schroeder, Indra; Fuck, Sebastian; Becker, Patrick; Jakob, Burkhard; Fournier, Claudia; Moroni, Anna; Thiel, Gerhard

    2015-09-09

    Ionizing radiation is a universal tool in tumor therapy but may also cause secondary cancers or cell invasiveness. These negative side effects could be causally related to the human-intermediate-conductance Ca2+-activated-K+-channel (hIK), which is activated by X-ray irradiation and affects cell proliferation and migration. To analyze the signaling cascade downstream of ionizing radiation we use genetically encoded reporters for H2O2 (HyPer) and for the dominant redox-buffer glutathione (Grx1-roGFP2) to monitor with high spatial and temporal resolution, radiation-triggered excursions of H2O2 in A549 and HEK293 cells. The data show that challenging cells with ≥1 Gy X-rays or with UV-A laser micro-irradiation causes a rapid rise of H2O2 in the nucleus and in the cytosol. This rise, which is determined by the rate of H2O2 production and glutathione-buffering, is sufficient for triggering a signaling cascade that involves an elevation of cytosolic Ca2+ and eventually an activation of hIK channels.

  8. Determination of Fission Products in Irradiated Fuel by X-Ray Fluorescence

    DEFF Research Database (Denmark)

    Mogensen, Mogens Bjerg; Als-Nielsen, Jens Aage; Andersen, Niels Hessel

    X-ray fluorescence i s a well e s t a b l i s h e d analytical tool for measuring elemental composition of fairly large (~ 5 cm2) "cold" samples. A version of t h i s technique has been developed for a n a l y s i s of radial d i s t r i b u t i o n of f i s s i o n products Xe, Cs and Ba...... in irradiated U02 fuel samples. About 0.1 mm thin s l i c e s of fuel p e l l e t s (full cross sections) are irradiated by 50 keV X-rays. The i n t e n s i t y of the Xe (Cs, Ba) Ko fluorescence radiation generated i s measured by means of a Ge detector f i t t ed with a collimator. The s l i t i s 0.5 mm wide...

  9. Long-term hematopoietic stem cell damage after external irradiation with X rays

    International Nuclear Information System (INIS)

    Grande, M.T.; Varas, F.; Bueren, J.A.

    1997-01-01

    We have investigated the functionality of the lympho-hematopoietic stem cells long-term (9 months) after the irradiation (X rays) of mice at different stages of development, by means of a competitive bone marrow repopulation assay. Our data revealed that a dose of 1 Gy was only capable of inducing significant long-term failures in the functionality of the primitive repopulating cells in mice irradiated at the young-adult stage (12 week-old), but not in mice irradiated at the late stages of foetus development (17 day-old fetuses) nor at the early development of the embryo (4 day-old embryos). The differential generation of long-term stem cell defects as a function of the age was confirmed in mice irradiated with 3 Gy. While no significant effects in the long-term repopulating cells were observed in 4 day-old embryos, significant repopulation deficiencies were observed in this population when mice were irradiated at the 17 day of foetus development, and more markedly at the adult stage of growth. These data offer new evidence about the influence of the developmental stage of the animal on the generation of residual hematopoietic dysfunctions by external irradiation, with particular relevance to the very primitive lympho-hematopoietic stem cells. (author)

  10. The effects of x-ray irradiation on the inner ear

    International Nuclear Information System (INIS)

    Kanagawa, Kiyoto

    1983-01-01

    Since the beginning of the 20th century, it has been known that the radiation can cause hearing loss, but the details of this process are not as well known as those of radiation effects on other organs. The author studied the effects of single dose of x-ray irradiation on the inner ear of guinea pigs by continuously measurement of cochlear microphonics (CM) and auditory brainstem responses (ABR) with permanent electrodes implanted on the round window and in the skull. With 2,000, 4,000, and 6,000 rad, slight conductive hearing impairment was observed in some guinea pigs. Severe sensorineural hearing loss was acutely induced by irradiation more than 8,000 rad. After 10,000 rad irradiation, both CM and ABR to air and bone conduction stimuli were usually enhanced by 20-50% above the pre-irradiation levels for one or two hours after completion of the irradiation, and they disappeared simultaneously about 6 hours after irradiation. Hearing impairment began earlier with increase in irradiation: about 10 hours at 8,000 rad, about 6 hours at 10,000 rad, and about 3 hours at 12,000 rad. Responses to high frequency sounds generally disappeared slightly earlier than those to low frequencies. The I-III interpeak latency of ABR didn't change after 10,000 rad irradiation. Endocochlear potential (EP) drop to about 30mV was observed about 7 hours after 10,000 rad irradiation. In the scanning electron micrographs, the sensory hairs in the outer and inner hair cells of every turn seemed to be normal 6 hours after 10,000 rad irradiation. In transmission electron microscopy, however, heavy damages were seen at the outer hair cells in the basal coil of the cochlea. (author)

  11. Toward an organ based dose prescription method for the improved accuracy of murine dose in orthovoltage x-ray irradiators

    International Nuclear Information System (INIS)

    Belley, Matthew D.; Wang, Chu; Nguyen, Giao; Gunasingha, Rathnayaka; Chao, Nelson J.; Chen, Benny J.; Dewhirst, Mark W.; Yoshizumi, Terry T.

    2014-01-01

    Purpose: Accurate dosimetry is essential when irradiating mice to ensure that functional and molecular endpoints are well understood for the radiation dose delivered. Conventional methods of prescribing dose in mice involve the use of a single dose rate measurement and assume a uniform average dose throughout all organs of the entire mouse. Here, the authors report the individual average organ dose values for the irradiation of a 12, 23, and 33 g mouse on a 320 kVp x-ray irradiator and calculate the resulting error from using conventional dose prescription methods. Methods: Organ doses were simulated in the Geant4 application for tomographic emission toolkit using the MOBY mouse whole-body phantom. Dosimetry was performed for three beams utilizing filters A (1.65 mm Al), B (2.0 mm Al), and C (0.1 mm Cu + 2.5 mm Al), respectively. In addition, simulated x-ray spectra were validated with physical half-value layer measurements. Results: Average doses in soft-tissue organs were found to vary by as much as 23%–32% depending on the filter. Compared to filters A and B, filter C provided the hardest beam and had the lowest variation in soft-tissue average organ doses across all mouse sizes, with a difference of 23% for the median mouse size of 23 g. Conclusions: This work suggests a new dose prescription method in small animal dosimetry: it presents a departure from the conventional approach of assigninga single dose value for irradiation of mice to a more comprehensive approach of characterizing individual organ doses to minimize the error and uncertainty. In human radiation therapy, clinical treatment planning establishes the target dose as well as the dose distribution, however, this has generally not been done in small animal research. These results suggest that organ dose errors will be minimized by calibrating the dose rates for all filters, and using different dose rates for different organs

  12. Levels of 2-dodecylcyclobutanone in ground beef patties irradiated by low-energy X-ray and gamma rays.

    Science.gov (United States)

    Hijaz, Faraj M; Smith, J Scott

    2010-01-01

    Food irradiation improves food safety and maintains food quality by controlling microorganisms and extending shelf life. However, acceptance and commercial adoption of food irradiation is still low. Consumer groups such as Public Citizen and the Food and Water Watch have opposed irradiation because of the formation of 2-alkylcyclobutanones (2-ACBs) in irradiated, lipid-containing foods. The objectives of this study were to measure and to compare the level of 2-dodecylcyclobutanone (2-DCB) in ground beef irradiated by low-energy X-rays and gamma rays. Beef patties were irradiated by low-energy X-rays and gamma rays (Cs-137) at 3 targeted absorbed doses of 1.5, 3.0, and 5.0 kGy. The samples were extracted with n-hexane using a Soxhlet apparatus, and the 2-DCB concentration was determined with gas chromatography-mass spectrometry. The 2-DCB concentration increased linearly (P irradiation dose for gamma-ray and low-energy X-ray irradiated patties. There was no significant difference in 2-DCB concentration between gamma-ray and low-energy X-ray irradiated patties (P > 0.05) at all targeted doses. © 2010 Institute of Food Technologists®

  13. Stimulation of post-traumatic regeneration of skeletal muscles of old rats after x-ray irradiation

    International Nuclear Information System (INIS)

    Bulyakova, N.V.; Popova, M.F.

    1987-01-01

    The authors seek a method of stimulating restorative processes in irradiated muscles of old animals. Rats were used in the experiments. Different series of experiments were performed, including complete transverse section of the gastrocnemius muscle after local x-ray irradiation, and laser therapy of the transversly divided gastrocnemius muscle. Post-traumatic regeneration of the gastrocnemius muscle of old rats is illustrated schematically. The experimental data showed that pulsed laser therapy or grafting of minced unirradiated muscle tissue can largely restore the regenerative capacity of the gastrocnemius muscle of old rats when depressed by x-ray irradiation, but the method of grafting minced unirradiated muscle tissue was more effective

  14. Concept development of X-ray mass thickness detection for irradiated items upon electron beam irradiation processing

    Science.gov (United States)

    Qin, Huaili; Yang, Guang; Kuang, Shan; Wang, Qiang; Liu, Jingjing; Zhang, Xiaomin; Li, Cancan; Han, Zhiwei; Li, Yuanjing

    2018-02-01

    The present project will adopt the principle and technology of X-ray imaging to quickly measure the mass thickness (wherein the mass thickness of the item =density of the item × thickness of the item) of the irradiated items and thus to determine whether the packaging size and inside location of the item will meet the requirements for treating thickness upon electron beam irradiation processing. The development of algorithm of X-ray mass thickness detector as well as the prediction of dose distribution have been completed. The development of the algorithm was based on the X-ray attenuation. 4 standard modules, Al sheet, Al ladders, PMMA sheet and PMMA ladders, were selected for the algorithm development. The algorithm was optimized until the error between tested mass thickness and standard mass thickness was less than 5%. Dose distribution of all energy (1-10 MeV) for each mass thickness was obtained using Monte-carlo method and used for the analysis of dose distribution, which provides the information of whether the item will be penetrated or not, as well as the Max. dose, Min. dose and DUR of the whole item.

  15. Expression of LY6D is induced at the surface of MCF10A cells by X-ray irradiation.

    Science.gov (United States)

    Kurosawa, Maiko; Jeyasekharan, Anand D; Surmann, Eva-Maria; Hashimoto, Noboru; Venkatraman, Vignesh; Kurosawa, Gene; Furukawa, Koichi; Venkitaraman, Ashok R; Kurosawa, Yoshikazu

    2012-12-01

    In order to identify membrane proteins whose expression is induced by X-ray irradiation, we developed an antibody (Ab)-directed strategy using a phage Ab library. X-Ray-irradiated cells were screened with a phage Ab library in the presence of a large excess of polyclonal Abs prepared against membrane proteins that are commonly present at the surface of both X-ray-irradiated and nonirradiated cells. After isolation of Ab that bound only to X-ray-irradiated cells, the antigen was identified using MS. Using this approach, we found that expression of LY6D is induced in MCF10A cells by X-ray irradiation. The induction of LY6D expression is triggered through a pathway regulated by ATM, CHK2 and p53. This method is a new Ab-directed proteomic strategy for analysis of membrane proteins, and is applicable to various biological phenomena in situations in which both target molecule-expressing cells and nonexpressing cells are available. © 2012 The Authors Journal compilation © 2012 FEBS.

  16. The inhibition effect of P-glycoprotein on cytochrome c release and caspase-3 activation by X-ray irradiation

    International Nuclear Information System (INIS)

    Chen Jun; Yu Zhijian; Xiao Mingxing; Pu Junguo; Zhang Zhiren

    2006-01-01

    Objective: To investigate the effects of P-glycoprotein (P-gp) on cytochrome c (Cyt c) release and caspase-3 activation in drug-resistant tumor cell after X-ray irradiation. Methods: Anti-P-gp McAb UIC-2 was applied to block P-gp function. MCF-7/Adr, P-gp-overexpressed drug-resistant breast cancer cell line, was irradiated by X-rays. Flow cytometry was used to measure apoptosis, dynamic changes of mitochondrial cytochrome c release and caspase-3 activation at various time after X-ray irradiation. Results: Both the expression of cyt c and the activation of caspase-3 in P-gp-blocked group were up-regulated significantly, compared with those in control group at 6 h, 12 h, and 24 h after X-ray irradiation, respectively. Conclusion: The current study showed that inhibition of P-gp function can increase cytochrome c release and caspase-3 activation. It suggested that P-gp inhibits cytochrome c release and caspase-3 activation induced by X-ray irradiation. (authors)

  17. Soft X-ray irradiation of methanol ice: Formation of products as a function of photon energy

    International Nuclear Information System (INIS)

    Chen, Y.-J.; Juang, K.-J.; Yih, T.-S.; Ciaravella, A.; Cecchi-Pestellini, C.; Muñoz Caro, G. M.; Jiménez-Escobar, A.

    2013-01-01

    Pure methanol ices have been irradiated with monochromatic soft X-rays of 300 and 550 eV close to the 1s resonance edges of C and O, respectively, and with a broadband spectrum (250-1200 eV). The infrared (IR) spectra of the irradiated ices show several new products of astrophysical interest such as CH 2 OH, H 2 CO, CH 4 , HCOOH, HCOCH 2 OH, CH 3 COOH, CH 3 OCH 3 , HCOOCH 3 , and (CH 2 OH) 2 , as well as HCO, CO, and CO 2 . The effect of X-rays is the result of the combined interactions of photons and electrons with the ice. A significant contribution to the formation and growth of new species in the CH 3 OH ice irradiated with X-rays is given by secondary electrons, whose energy distribution depends on the energy of X-ray photons. Within a single experiment, the abundances of the new products increase with the absorbed energy. Monochromatic experiments show that product abundances also increase with the photon energy. However, the abundances per unit energy of newly formed species show a marked decrease in the broadband experiment as compared to irradiations with monochromatic photons, suggesting a possible regulatory role of the energy deposition rate. The number of new molecules produced per absorbed eV in the X-ray experiments has been compared to those obtained with electron and ultraviolet (UV) irradiation experiments.

  18. Automatic vertebral bodies detection of x-ray images using invariant multiscale template matching

    Science.gov (United States)

    Sharifi Sarabi, Mona; Villaroman, Diane; Beckett, Joel; Attiah, Mark; Marcus, Logan; Ahn, Christine; Babayan, Diana; Gaonkar, Bilwaj; Macyszyn, Luke; Raghavendra, Cauligi

    2017-03-01

    Lower back pain and pathologies related to it are one of the most common results for a referral to a neurosurgical clinic in the developed and the developing world. Quantitative evaluation of these pathologies is a challenge. Image based measurements of angles/vertebral heights and disks could provide a potential quantitative biomarker for tracking and measuring these pathologies. Detection of vertebral bodies is a key element and is the focus of the current work. From the variety of medical imaging techniques, MRI and CT scans have been typically used for developing image segmentation methods. However, CT scans are known to give a large dose of x-rays, increasing cancer risk [8]. MRI can be substituted for CTs when the risk is high [8] but are difficult to obtain in smaller facilities due to cost and lack of expertise in the field [2]. X-rays provide another option with its ability to control the x-ray dosage, especially for young people, and its accessibility for smaller facilities. Hence, the ability to create quantitative biomarkers from x-ray data is especially valuable. Here, we develop a multiscale template matching, inspired by [9], to detect centers of vertebral bodies from x-ray data. The immediate application of such detection lies in developing quantitative biomarkers and in querying similar images in a database. Previously, shape similarity classification methods have been used to address this problem, but these are challenging to use in the presence of variation due to gross pathology and even subtle effects [1].

  19. Effects of x-ray and neutron irradiation on spherical colonies

    International Nuclear Information System (INIS)

    Aramaki, Ryoji

    1980-01-01

    Responses of in vitro cultured mammalian cells in spherical colonies to 200 kVp x-rays and D-T neutrons were studied using reproductive capacity as a criterion for survival. Cell lines used were FM3A, L5 and Chinese hamster V79. The spherical colonies exposed to x-rays exhibited two-component survival curves. All cells used were more radio-resistant in spherical colonies than in single cell suspensions. It was suggested that this difference in response was attributable to the presence of hypoxic cells in spherical colonies. Dose-modifying Factor (DMF), the ratios of D 0 of the second slopes of the curves for spherical colonies to those for single cells, were 1.6 for FM3A, 1.8 for L5, and 1.7 for Chinese hamster V79. The hypoxic cell fractions in spherical colonies for FM3A, L5, and Chinese hamster V79, were 0.1, 0.6 and 0.4, respectively, resulting in variations in cell survival in spherical colonies following x-radiation. No significant difference was observed between responses of spherical colonies and single cell suspensions to D-T neutrons. FM3A and Chinese hamster V79 showed two-component survival curves when irradiated with neutrons at 37 0 C, but not at 25 0 C. The repair of potentially lethal and sub-lethal damage was also investigated using FM3A in spherical colonies. No detectable repair of potentially lethal damage was observed for x-rays and D-T neutrons. The effect of neutron fractionation was considerably smaller for spherical colonies as compared to single cells. (author)

  20. ROS enhancement by silicon nanoparticles in X-ray irradiated aqueous suspensions and in glioma C6 cells

    International Nuclear Information System (INIS)

    David Gara, Pedro M.; Garabano, Natalia I.; Llansola Portoles, Manuel J.; Moreno, M. Sergio; Dodat, Diego; Casas, Oscar R.; Gonzalez, Mónica C.; Kotler, Mónica L.

    2012-01-01

    The capability of silicon nanoparticles to increase the yield of reactive species upon 4 MeV X-ray irradiation of aqueous suspensions and C6 glioma cell cultures was investigated. ROS generation was detected and quantified using several specific probes. The particles were characterized by FTIR, XPS, TEM, DLS, luminescence, and adsorption spectroscopy before and after irradiation to evaluate the effect of high energy radiation on their structure. The total concentration of O 2 •− /HO 2 • , HO • , and H 2 O 2 generated upon 4-MeV X-ray irradiation of 6.4 μM silicon nanoparticle aqueous suspensions were on the order of 10 μM per Gy, ten times higher than that obtained in similar experiments but in the absence of particles. Cytotoxic 1 O 2 was generated only in irradiation experiments containing the particles. The particle surface became oxidized to SiO 2 and the luminescence yield reduced with the irradiation dose. Changes in the surface morphology did not affect, within the experimental error, the yields of ROS generated per Gy. X-ray irradiation of glioma C6 cell cultures with incorporated silicon nanoparticles showed a marked production of ROS proportional to the radiation dose received. In the absence of nanoparticles, the cells showed no irradiation-enhanced ROS generation. The obtained results indicate that silicon nanoparticles of 1 O 2 upon X-ray irradiation opens novel approaches in the design of therapy strategies.

  1. Effects of x-ray irradiation on male navel orangeworm (Lepidoptera: Pyralidae) on mating, fecundity, fertility, and inherited sterility

    Science.gov (United States)

    Male adult navel orangeworm, Amyelois transitella, were irradiated using a laboratory x-ray emitter to determine the dose needed to achieve complete egg sterility of mated female moths and inherited egg sterility of F1 generation. Adult male A. transitella were irradiated in a series of two experime...

  2. Effects of X-ray irradiation on different stages of Sesamia nonagrioides Lefebvre (Lepidoptera: Noctuidae) and DNA damage

    Science.gov (United States)

    Avan Aksoy, Hatice; Yazıcı, Nizamettin; Erel, Yakup

    2017-01-01

    The corn stalk borer, Sesamia nonagrioides Lefebvre (Lepidoptera: Noctuidae) is an important corn pest in the Mediterranean countries. In this study, we investigated the influence of X-ray irradiation on different developmental stages, reproduction and DNA damage to the insect. Eggs (0-24 h old), larvae (5th instar), pupae (5 days after pupation) and adults (24 h after emergence) were irradiated with X-ray irradiation at target doses of 0 (control), 50, 100, 150 and 200 Gy. Eggs irradiated at all doses did not hatch. When 5th instar were irradiated pupation and adult emergence significantly decreased. Fecundity of adults from irradiated pupae was inhibited and no eggs were laid. Moreover, adult longevity decreased after irradiation compared to control. Larvae, pupae, and adults of S. nonagrioides were studied using the single-cell gel electrophoresis (DNA comet) directly after irradiation. X-ray irradiated larvae, pupae, and adults showed typical DNA fragmentation in a dose-dependent manner compared with cells from non-irradiated groups. The amount of DNA damage increased as doses increased and possibly could be used to estimate dose applied in commercial phytosanitary irradiation treatments. Furthermore, irradiation would be an effective phytosanitary treatment for shipped commodities at risk infestation with S. nonagrioides.

  3. Electron channeling X-ray microanalysis for cation configuration in irradiate magnesium alimate spinel

    International Nuclear Information System (INIS)

    Matsumura, S.; Soeda, T.; Zaluzec, N. J.; Kinoshita, C.

    1999-01-01

    High angular resolution electron channeling X-ray spectroscopy (HARECXS) was examined as a practical tool to locate lattice-ions in spinel crystals. The orientation dependent intensity distribution of emitted X-rays obtained by HARECXS is so sensitive to lattice-ion configuration in the illuminated areas that the occupation probabilities on specific positions in the crystal lattice can be determined accurately through comparison with the theoretical rocking curves. HARECXS measurements have revealed partially disordered cation arrangement in MgO·nAl 2 O 3 with n = 1.0 and 2.4. Most Al 3+ lattice-ions occupy the octahedral (VIII) sites, while Mg 2 lattice-ions reside on both the tetrahedral (IV) and the octahedral (VIII) sites. The structural vacancies are enriched in the IV-sites. Further evacuation of cations from the IV-sites to the VIII-sites is recognized in a disordering process induced by irradiation with 1 MeV Ne + ions up to 8.9 dpa at 870 K

  4. X-ray source for irradiation of large-area objects

    Science.gov (United States)

    Petin, V. K.; Shljakhtun, S. V.; Oreshkin, V. I.; Ratakhin, N. A.

    2008-06-01

    The results of experiments with a three-ring large-area diode that were conducted on an MIG pulse generator are reported. The MIG generator makes it possible to produce in a matched load electrical pulses up to 2 TW in power with an FWHM of 50-60 ns (1.2-1.4 TW and 80-90 ns in our experiments). In the operating mode of the generator, the current amplitude through the load is 2 MA (the current of a relativistic electron beam) at a diode voltage of ≈ 500 kV. As a load, a large-area vacuum diode with three ring-shaped cathodes is used. It is shown that about 20% of the energy stored in the capacitor bank can be converted to the energy of a relativistic electron beam by matching the output resistance of the MIG generator to the load resistance. When the beam slows down on a condensed foil target, the parameters of the resulting source are the following: the mean energy of X-ray quanta is ≈ 70 keV; irradiated area, 500 cm2; pulse FWHM, 65 ns; energy flux in the spectrum, 2 J/cm2; and percentage of X-ray radiation (10-100 keV) in the flux, ≈ 50%.

  5. Validity of dual X-ray absorptiometry scanning for determination of body composition in IDDM patients

    DEFF Research Database (Denmark)

    Rosenfalck, A M; Almdal, T; Gotfredsen, A

    1995-01-01

    Data on body composition in patients with insulin-dependent diabetes mellitus (IDDM) are scarce. Dual X-ray absorptiometry (DXA) scanning has proved useful for this purpose in other groups of patients. We tested the validity of the DXA scanner for the determination of fat-free mass (FFM) and fat...... mass in IDDM patients and control subjects, as compared to other reference methods, i.e. total body potassium by 40K whole body counting (TBK), total body water by tritiated water (TBW), bioelectrical impedance analysis (BIA) and 24-h urinary creatinine excretion (Ucrea). A total of 13 healthy controls...

  6. X-ray (image)

    Science.gov (United States)

    X-rays are a form of ionizing radiation that can penetrate the body to form an image on ... will be shades of gray depending on density. X-rays can provide information about obstructions, tumors, and other ...

  7. Effects of X-ray irradiation on the microbial growth and quality of flue-cured tobacco during aging

    Science.gov (United States)

    Wang, J. J.; Xu, Z. C.; Fan, J. L.; Wang, Y.; Tian, Z. J.; Chen, Y. T.

    2015-06-01

    X-ray irradiation was evaluated for improving microbial safety and the quality of flue-cured tobacco during aging. Tobacco samples were irradiated at doses of 0, 1, 2, 3 and 5 kGy and stored for 12 months under normal storage conditions or in a high-humidity (RH>70%) room. Microbiological data indicated that the population of total aerobic bacteria was significantly decreased with increasing irradiation doses. In particular, a dose of 2 kGy was effective for the decontamination of fungi from the tested samples, with a 0.93 log CFU/g reduction for bacteria. The control and 1 kGy X-ray treated tobacco samples were became rotted and moldy after the 12th month, whereas those treated with 2, 3 and 5 kGy had no detectable mold during 12 months of storage at high humidity. Chemical measurements showed that irradiation up to 3 kGy did not affect the total nitrogen, nicotine, reducing and total sugars, ratio of total nitrogen to nicotine and sugar-to-nicotine ratio. Furthermore, sensory evaluation results also showed that X-ray irradiation did not affect sensory scores with irradiation at a dose <3 kGy. Based on these results, X-ray irradiation dose in the range of 2-3 kGy is recommended for the decontamination of fungi from flue-cured tobacco.

  8. Comparison of the effect of X-ray and electron beam irradiation on the thiamine content in chicken drumsticks

    International Nuclear Information System (INIS)

    Calenberg, S. van; Cleemput, O. van; Huyghebaert, A.; Mondelaers, W.

    1998-01-01

    The effect of irradiation with X-rays and electron beams on the thiamine content of chicken drumsticks in function of the storage time at refrigerator temperature was examined. A measurement of the total colony count was used as an indication of the preservation time. The irradiation dose applied ranged from 0 to 7 kGy at dose rates of 0.05 and 5 kGy/min for X-rays and electron beams respectively. It was concluded that differences in the thiamine breakdown between the two types of irradiation increased as the dose increased. In the worst case, at the X-ray treatment of 7 kGy, the mean loss in thiamine was 46.06%

  9. In-situ measurement of the strain relaxation of GaN nanograins during X-ray irradiation

    International Nuclear Information System (INIS)

    Choe, Hyeokmin; Lee, Sanghwa; Sohn, Yuri; Kim, Chinkyo

    2008-01-01

    GaN nanograins were grown on a c-plane sapphire substrate and their strain relaxation due to X-ray irradiation was investigated in-situ by utilizing synchrotron xray scattering. The GaN nanograins were constantly exposed to the synchrotron X-ray and θ-2θ scans through the (002) Bragg peak of GaN were repeatedly carried out during the irradiation. The Bragg peak of the compressively strained GaN nanograins gradually shifted toward higher angle, which implies that the GaN nanograins in compressive strain experienced strain relaxation during X-ray irradiation. (copyright 2008 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  10. Some peculiarities of the X-ray image of foreign bodies in the stomach

    International Nuclear Information System (INIS)

    Georgieva, S.; Chernev, I.; Khubenski, S.; Palikarski, S.; Naraliev, V.

    1991-01-01

    17 patient swallowed wooden objects have been observed. After abdomenoscopy a conventional X-ray study of the stomach has been made by routine contrast technique in polypositional conditions and fractionated resorption of the contrast matter and fixed creeping compression. A periodical control of the foreign body movement in distal direction is made. The following specific features of the X-ray image are pointed out: the presence of fluid and mucus in an empty hypotonic stomach; progressive intensifying hypotonia of the stomach; gradually increase of the fluid. In recumbent position the foreign bodies show a negative density of respective forms and size. In errect position they 'float' over the contrast matter against the background of the air bubble of the fornix, showing a positive-negative density. When staying for a longer time in the stomach their volume shows a moderate increase. Experimental investigations in-vitro with the same wooden bodies show certain differences in the X-ray image compared to one observed in-vivo, which is due to the presence of fluid and mucus in the stomach. 3 figs., 15 refs

  11. Carbon-ion beam irradiation kills X-ray-resistant p53-null cancer cells by inducing mitotic catastrophe.

    Directory of Open Access Journals (Sweden)

    Napapat Amornwichet

    Full Text Available BACKGROUND AND PURPOSE: To understand the mechanisms involved in the strong killing effect of carbon-ion beam irradiation on cancer cells with TP53 tumor suppressor gene deficiencies. MATERIALS AND METHODS: DNA damage responses after carbon-ion beam or X-ray irradiation in isogenic HCT116 colorectal cancer cell lines with and without TP53 (p53+/+ and p53-/-, respectively were analyzed as follows: cell survival by clonogenic assay, cell death modes by morphologic observation of DAPI-stained nuclei, DNA double-strand breaks (DSBs by immunostaining of phosphorylated H2AX (γH2AX, and cell cycle by flow cytometry and immunostaining of Ser10-phosphorylated histone H3. RESULTS: The p53-/- cells were more resistant than the p53+/+ cells to X-ray irradiation, while the sensitivities of the p53+/+ and p53-/- cells to carbon-ion beam irradiation were comparable. X-ray and carbon-ion beam irradiations predominantly induced apoptosis of the p53+/+ cells but not the p53-/- cells. In the p53-/- cells, carbon-ion beam irradiation, but not X-ray irradiation, markedly induced mitotic catastrophe that was associated with premature mitotic entry with harboring long-retained DSBs at 24 h post-irradiation. CONCLUSIONS: Efficient induction of mitotic catastrophe in apoptosis-resistant p53-deficient cells implies a strong cancer cell-killing effect of carbon-ion beam irradiation that is independent of the p53 status, suggesting its biological advantage over X-ray treatment.

  12. Anomalous small-angle x-ray scattering of a femtosecond irradiated germano silicate fibre preform.

    Energy Technology Data Exchange (ETDEWEB)

    Hindle, F.; Fertein, E.; Seifert, S.; Przygodski, C.S.; Bocquet, R.; Douay, M.; Bychkov, E.; Experimental Facilities Division (APS); LPCA, CNRS; PhLAM; Univ. des Sciences et Tech. de Lille

    2005-01-01

    RADIATION is shown to induce significant mesoscopic structure. The scattering intensity for irradiated glasses is close to two orders of magnitude greater than that of unexposed material. Anomalous small-angle X-ray scattering (ASAXS) around the germanium K-edge for the silica and germanium doped silica regions of a fiber preform is used to demonstrate that identical structures are induced in both glass materials, with germanium displaying a capacity to isomorphically replace silicon in the case of the germanium doped silica. Analysis of measured scattering indicates that photo-inscribed features are produced at two distinct scales with typical radii of R {approx} 20 Angstroms and R{sub min} {approx} 200 Angstroms.

  13. ESR dosimetry below 1 Gy, in X-ray irradiated tooth enamel

    International Nuclear Information System (INIS)

    Fainstein, Carlos; Winkler, Elin

    2000-01-01

    Tooth enamel, extracted from molars, was irradiated with 66 keV X-rays, with doses up to 1 Gy. The preparation of the powder samples is described, as well as the protocol for the acquisition and processing of the spectra. The radiation induced paramagnetism is measured, at room temperature, by ESR Spectroscopy. The ESR spectra is well described considering two paramagnetic species, with magnetic moments (in units of Bohr magneton) g=2,0041, and g 1 =2,0018, g 2 =1,9972. The ESR data (peak-to-peak amplitude per mg, hpp/mg, vs dose D), for doses 0 Gy 2 =0,996) with the linear expression: [hpp/mg] = -0,2(0,4)+14,9(0,5). D [Gy]. The result supports the growing confidence in the use of this material, and method, in Retrospective Dosimetry. (author)

  14. Study of human blood and hemocomponents irradiated by low angle x ray scattering (LAXS)

    International Nuclear Information System (INIS)

    Pinto, Nivia G. Villela; Barroso, Regina C.; Mota, Carla L.S.; Almeida, Andre P.; Azeredo, Soraia R.; Braz, Delson

    2009-01-01

    Irradiation of blood and blood components is currently practiced in developed and in a few developing countries. The main purpose of this process is the prevention of graft versus host disease in immunodeficient patients. The Food and Drug Administration recommends a dose range of 15 Gy to 25 Gy for these blood components. When x-ray photons are scattered from biological samples, their angular distribution shows one or more peaks in the forward direction of scattering. These peaks are characteristic for the investigated samples. Due to its wide range of biological and medical applications, low-angle x-ray scattering has attracted the attention of many authors. Thus in this present work was studied the possible variations in scattering profiles due to the irradiation when the gender of patients was considered. Fresh blood specimens were obtained from volunteers using vacutainer tubes containing EDTA, at the Dr. Eliel Figueiredo Laboratory, Rio de Janeiro. All the samples were lyophilized for 48 hours in a freeze drier in order to remove the water. The scattering measurements were carried out in e-2e reflection geometry using a powder diffractometer Shimadzu XRD- 6000. The measured characterization parameters for LAXS were associated with epidemiological data (gender). The mean values of the different parameters were compared using the Students's t-test for each characterization parameters. The scattering profiles from plasma and formed elements are characterized by the presence of two peaks in the forward direction of scattering. For epidemiological data (gender) analyzed was not found significant changes in the mostly of characterization parameters (p>0.05). (author)

  15. Study of human blood and hemocomponents irradiated by low angle x ray scattering (LAXS)

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Nivia G. Villela; Barroso, Regina C. [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. de Fisica. Dept. de Fisica Aplicada e Termodinamica], e-mail: nitatag@gmail.com; Mota, Carla L.S.; Almeida, Andre P.; Azeredo, Soraia R.; Braz, Delson [Coordenacao dos Programas de Pos-graduacao em Engenharia (COPPE/UFRJ), RJ (Brazil). Lab. de Instrumentacao Nuclear], e-mail: delson@lin.ufrj.br

    2009-07-01

    Irradiation of blood and blood components is currently practiced in developed and in a few developing countries. The main purpose of this process is the prevention of graft versus host disease in immunodeficient patients. The Food and Drug Administration recommends a dose range of 15 Gy to 25 Gy for these blood components. When x-ray photons are scattered from biological samples, their angular distribution shows one or more peaks in the forward direction of scattering. These peaks are characteristic for the investigated samples. Due to its wide range of biological and medical applications, low-angle x-ray scattering has attracted the attention of many authors. Thus in this present work was studied the possible variations in scattering profiles due to the irradiation when the gender of patients was considered. Fresh blood specimens were obtained from volunteers using vacutainer tubes containing EDTA, at the Dr. Eliel Figueiredo Laboratory, Rio de Janeiro. All the samples were lyophilized for 48 hours in a freeze drier in order to remove the water. The scattering measurements were carried out in e-2e reflection geometry using a powder diffractometer Shimadzu XRD- 6000. The measured characterization parameters for LAXS were associated with epidemiological data (gender). The mean values of the different parameters were compared using the Students's t-test for each characterization parameters. The scattering profiles from plasma and formed elements are characterized by the presence of two peaks in the forward direction of scattering. For epidemiological data (gender) analyzed was not found significant changes in the mostly of characterization parameters (p>0.05). (author)

  16. The evaluation of in vitro characteristics of red blood cells in blood products after x-ray irradiation

    International Nuclear Information System (INIS)

    Fukumori, Yasuo; Tanaka, Shigenori; Sugimoto, Akiko; Ohnoki, Shiro; Yamaguchi, Hideo

    1990-01-01

    Irradiation with X-ray to blood products is a standard practice recommended for prevention of post-transfusion graft versus host disease in patients. In order to seek the optimal condition of irradiation to minimize the lesion of red blood cell (RBC) with complete inactivation of lymphocytes, we studied the effects of irradiation with X-ray on the quality of RBC in whole blood (WB) and concentrated red blood cells (CRC) in the range of 5 to 50 Gy. X-ray irradiation did not alter ATP and 2,3-DPG content, hemolysis ending point and morphology of RBC, while it caused a slight increase of osmotic pressure at hemolysis starting point of RBC and potassium concentration in plasma. Considerable increase of hemolysis was observed with higher dose of irradiation in both WB and CRC. However, it was so small as below 2-3 x 10 -2 percent that is acceptable level in blood products. Therefore, we concluded that the X-ray irradiation of WB and CRC with up to 50 Gy has no significant effects on in vitro characteristics of RBC. (author)

  17. Determination of the metal balance shift induced in small fresh water fish by X-ray irradiation using PIXE analysis

    International Nuclear Information System (INIS)

    Yukawa, M.; Iso, H.; Kodama, K.; Imaseki, H.; Aoki, K.; Ishikawa, Y.

    2007-01-01

    The balance of essential elements in organisms can be changed by environmental stresses. A small fresh water fish, the medaka, was irradiated with X-rays (total dose: 17 Gy, which is not a lethal dose for this fish). Essential elements in the liver, gall bladder, kidney, spleen, heart and brain of the fish were measured by the particle induced X-ray emission (PIXE) method and compared with those of a control fish. Various changes in the elemental balance shift were observed. The PIXE method can analyze many elements in a small sample simultaneously, and so the changes in elemental content induced by irradiation were readily determined. (author)

  18. Study of serotonin effect on the yield of some damages in DNA after ultraviolet and x-ray irradiations

    International Nuclear Information System (INIS)

    Ivanova, Eh.V.; Frajkin, G.Ya.

    1985-01-01

    Using thin-layer two-dimensional chromatography serotonin effect on the yield of thymine dimers and appearance of n-glycoside strand breaks in DNA (thymine yield) after ultraviolet and X-ray irradiation is studied. It is shown that bound with DNA serotonin decreases formation of induced by ultraviolet thymine dimers but doesn't affect on the quantity of N-glycoside bond breaks in thymidine residues caused by X radiation. The obtained data are discussed in relation to the problem on mechanisms of realization of serotonin protective effect in the processes of yeast Saccharomyces photoprotection from ultraviolet and X-ray irradiation lethal effect

  19. Evaluation of some selected vaccines and other biological products irradiated by gamma rays, electron beams and X-rays

    Energy Technology Data Exchange (ETDEWEB)

    May, J.C. E-mail: may@cber.fda.gov; Rey, L.; Lee, C.-J

    2002-03-01

    Molecular sizing potency results are presented for irradiated samples of one lot of Haemophilus b conjugate vaccine, pneumococcal polysaccharide type 6B and typhoid vi polysaccharide vaccine. The samples were irradiated (25 kGy) by gamma rays, electron beams and X-rays. IgG and IgM antibody response in mice test results (ELISA) are given for the Hib conjugate vaccine irradiated at 0 deg. C or frozen in liquid nitrogen.

  20. Ion, X-ray, UV and Neutron Microbeam Systems for Cell Irradiation.

    Science.gov (United States)

    Bigelow, A W; Randers-Pehrson, G; Garty, G; Geard, C R; Xu, Y; Harken, A D; Johnson, G W; Brenner, D J

    2010-08-08

    The array of microbeam cell-irradiation systems, available to users at the Radiological Research Accelerator Facility (RARAF), Center for Radiological Research, Columbia University, is expanding. The HVE 5MV Singletron particle accelerator at the facility provides particles to two focused ion microbeam lines: the sub-micron microbeam II and the permanent magnetic microbeam (PMM). Both the electrostatic quadrupole lenses on the microbeam II system and the magnetic quadrupole lenses on the PMM system are arranged as compound lenses consisting of two quadrupole triplets with "Russian" symmetry. Also, the RARAF accelerator is a source for a proton-induced x-ray microbeam (undergoing testing) and is projected to supply protons to a neutron microbeam based on the (7)Li(p, n)(7)Be nuclear reaction (under development). Leveraging from the multiphoton microscope technology integrated within the microbeam II endstation, a UV microspot irradiator - based on multiphoton excitation - is available for facility users. Highlights from radiation-biology demonstrations on single living mammalian cells are included in this review of microbeam systems for cell irradiation at RARAF.

  1. Carbonate-derivative centers in x-ray irradiated carbonate-containing apatites

    International Nuclear Information System (INIS)

    Doi, Yutaka; Aoba, Takaaki; Okazaki, Masayuki; Takahashi, Junzo; Moriwaki, Yutaka.

    1981-01-01

    13 C-enriched carbonate-containing apatites were X-ray irradiated at room temperature or at liquid nirogen temperature and investigated by means of electron spin responance (ESR) spectroscopy. Two sets of 13 C doublet were observed from 13 C-enriched samples when the samples were irradiated at room temperature, whereas no signal due to 13 C was observed when irradiated at -196 0 C. These new sets of the 13 C doublet have been interpreted in terms of two distinct carbonate-derivative centers I and II. The asymmetric signal appeared at the center of the X-band ESR spectrum has been interpreted in terms of three paramagnetic centers. One of them is assigned to an electron-trapped center, though the exact site of the trapped electron is unknown, and two of them are the carbonate-I center and carbonate-II center of 12 C sub(I) and 12 C sub(II). From the Q-band (about 33 x 10 9 s -1 ) analysis it is found that the carbonate-I center gives an isotropic signal at g = 2.0002, whereas the carbonate-II center shows g tensor anisotropy and gives two peaks at g = 2.0017 and 1.9972. Possible explanations for assignment of the carbonate centers to CO 3 3- and CO 2 - have been made. (author)

  2. Ion, X-ray, UV and Neutron Microbeam Systems for Cell Irradiation

    Science.gov (United States)

    Bigelow, A.W.; Randers-Pehrson, G.; Garty, G.; Geard, C.R.; Xu, Y.; Harken, A.D.; Johnson, G. W.; Brenner, D.J.

    2012-01-01

    The array of microbeam cell-irradiation systems, available to users at the Radiological Research Accelerator Facility (RARAF), Center for Radiological Research, Columbia University, is expanding. The HVE 5MV Singletron particle accelerator at the facility provides particles to two focused ion microbeam lines: the sub-micron microbeam II and the permanent magnetic microbeam (PMM). Both the electrostatic quadrupole lenses on the microbeam II system and the magnetic quadrupole lenses on the PMM system are arranged as compound lenses consisting of two quadrupole triplets with “Russian” symmetry. Also, the RARAF accelerator is a source for a proton-induced x-ray microbeam (undergoing testing) and is projected to supply protons to a neutron microbeam based on the 7Li(p, n)7Be nuclear reaction (under development). Leveraging from the multiphoton microscope technology integrated within the microbeam II endstation, a UV microspot irradiator – based on multiphoton excitation – is available for facility users. Highlights from radiation-biology demonstrations on single living mammalian cells are included in this review of microbeam systems for cell irradiation at RARAF. PMID:23420504

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of knee x-rays. A portable x-ray machine is a compact apparatus that can be taken ... of the body being examined, an x-ray machine produces a small burst of radiation that passes ...

  4. Image-guided microbeam irradiation to brain tumour bearing mice using a carbon nanotube x-ray source array

    Science.gov (United States)

    Zhang, Lei; Yuan, Hong; Burk, Laurel M.; Inscoe, Christy R.; Hadsell, Michael J.; Chtcheprov, Pavel; Lee, Yueh Z.; Lu, Jianping; Chang, Sha; Zhou, Otto

    2014-03-01

    Microbeam radiation therapy (MRT) is a promising experimental and preclinical radiotherapy method for cancer treatment. Synchrotron based MRT experiments have shown that spatially fractionated microbeam radiation has the unique capability of preferentially eradicating tumour cells while sparing normal tissue in brain tumour bearing animal models. We recently demonstrated the feasibility of generating orthovoltage microbeam radiation with an adjustable microbeam width using a carbon nanotube based x-ray source array. Here we report the preliminary results from our efforts in developing an image guidance procedure for the targeted delivery of the narrow microbeams to the small tumour region in the mouse brain. Magnetic resonance imaging was used for tumour identification, and on-board x-ray radiography was used for imaging of landmarks without contrast agents. The two images were aligned using 2D rigid body image registration to determine the relative position of the tumour with respect to a landmark. The targeting accuracy and consistency were evaluated by first irradiating a group of mice inoculated with U87 human glioma brain tumours using the present protocol and then determining the locations of the microbeam radiation tracks using γ-H2AX immunofluorescence staining. The histology results showed that among 14 mice irradiated, 11 received the prescribed number of microbeams on the targeted tumour, with an average localization accuracy of 454 µm measured directly from the histology (537 µm if measured from the registered histological images). Two mice received one of the three prescribed microbeams on the tumour site. One mouse was excluded from the analysis due to tissue staining errors.

  5. Measurement of irradiation temperature and study of local overheating of claddings of austenitic steel, by X-ray diffraction

    International Nuclear Information System (INIS)

    Rousset, P.; Cadalbert, R.

    1983-01-01

    The development of fuel elements of fast neutron reactors makes the CEA effectuate numerous irradiations of steel in the RAPSODIE and PHENIX reactor. Detailed knowledge and control of the irradiation temperature pose an important problem both for experimental claddings and for fuel claddings used in these reactors. The authors utilize the relation that exists between the irradiation temperature and the failure density present in the austenitic steels, for measuring irradiation temperatures and for studying local overheating of the claddings by means of X-ray diffraction. In effect, the line widths of X-ray diffraction is a measure of the degree of lattice distortion. Quantitative analysis of this failure density enables to study the thermal profiles of the claddings in the assembly; to study local overheating (hot spots); and to measure the irradiation temperature in capsules. (Auth.)

  6. STUDY OF TIME LAPSE IN FOREIGN BODY ASPIRATION IN RELATION TO CHEST X - RAY AND TYPE OF FOREIGN BODY

    Directory of Open Access Journals (Sweden)

    Salma

    2015-10-01

    Full Text Available INTRODUCTI ON: Foreign body aspiration in pediatrics is a potentially fatal accident which will continue until children explore their surroundings with their hand and mouth. Pediatric aspirations will persist until mankind exists. Not all foreign body aspirations are witnessed hence chances of delay in diagnosing an aspiration are high. Delay in diagnosis depends on site and character of foreign body aspirated. The chest x - ray findings and type of foreign body extracted vary depending on the duration the foreign body remains in airway . OBJECTIVE: To study the X - ray finding in pediatric airway aspiration and its relation to time lapse, the type and site of lodgment of foreign body extracted via bronchoscopy. The type of foreign body in relation to time lapse in aspiration. MATERIAL AND METHODS: This was a prospective study done in Bapuji child health institute and research center, JJM Medical College, Davangere . History and pre bronchoscopy x - Ray finding were noted for 65 children who were posted for suspicious bronchoscopy from August 2011 to September 2013. 11 children were excluded from study as they showed no foreign body on bronchoscopy. Time lapse in aspir ation and seeking medical care was noted. The bronchoscopic findings regarding site of foreign body lodgment and type of foreign body were recorded. The type of foreign body and variation of x - ray picture in relation to time lapse in aspiration were noted. Data collected was analyzed using descriptive statistics. RESULT: It was observed that mean age was 28 months. About 80% of the cases were between 1 to 3 years age. 82% (n=53/54 were radio lucent foreign body, only 1.5% (n=1/54 were radio o paque. Site of lodgment of foreign body was right main bronchus in 48% (n=26/54, left main bronchus 46% (n=25/54 , tracheal 1.85% (n=1/54, subglottic 1.85% (n=1/54, carinal 1.85% (n=1/54, multiple site i.e. left bronchus +right bronchus+ carinal 1.85% (n=1/54. Groundnut was most common

  7. Health physics aspects in treatment rooms after 18-MV X-ray irradiations.

    Science.gov (United States)

    Kalef-Ezra, John A

    2011-09-01

    Delayed activation products contribute to the exposure of the staff operating high-energy accelerators. Induced activity was studied in a treatment room following 18-MV X-ray irradiations using a hand-held system that allows both dose rate measurements and spectroscopic analysis. The major activation products and the corresponding nuclear reactions were identified. At the majority of the studied locations, β(+) emitters were the main short-term dose contributors. The time variation of the absorbed dose rate in a treatment room during the first 20-min post-irradiation was represented by the sum of two exponential components with half-lives of 1-2 min and either 4 or 10 min, depending on the location in the room. Components with a half-life of hours or days contribute activation of some accessories, such as iron filters and portal imagers, deserve special attention. The collection of such data with the proposed method allows the development of optimised working protocols at each treatment room.

  8. Formation of color centers in ammonium perchlorate by x-ray irradiation at room temperature

    International Nuclear Information System (INIS)

    Levy, P.W.; Goldberg, M.; Herley, P.J.

    1978-01-01

    Radiation induced color center formation has been studied in single crystal ammonium perchlorate. Large, high purity, water clear single crystals were uniformly irradiated normal to the c or 001 face with filtered 60 kV x-rays at room temperature. The radiation induced coloring, measured through the c face, can be resolved into four Gaussian shaped absorption bands whose peak energies and full widths are 6.72, 1.62; 4.81, 0.88; 3.91, 1.12; and 2.47, 0.72 eV. The 6.72 band lies at the 'band-gap' or 'edge' and could represent either a shift in the edge or the superposition of one or more bands on the edge. The other bands are, most likely, defect related color centers or trapped molecular species. The coloring contains a small unstable component, at most 10%, consisting of these bands and an additional one at 5.78 eV, width 0.35 eV, which has a negligible effect on coloring kinetic determinations. The color-centers vs. dose curves for the bands at 6.72 and 2.47 eV are linear. The curves for the 4.81 and 3.91 eV bands contain a linear and one saturating exponential component. The linear components appear to be related to a linear dose induced process observed in the thermal decomposition of irradiated ammonium perchlorate. (author)

  9. Irradiation of intense characteristic x-rays from weakly ionized linear molybdenum plasma

    International Nuclear Information System (INIS)

    Sato, Eiichi; Hayasi, Yasuomi

    2003-01-01

    In the plasma flash x-ray generator, a high-voltage main condenser of approximately 200 nF is charged up to 55 kV by a power supply, and electric charges in the condenser are discharged to an x-ray tube after triggering the cathode electrode. The flash x-rays are then produced. The x-ray tube is a demountable triode that is connected to a turbo molecular pump with a pressure of approximately 1 mPa. As electron flows from the cathode electrode are roughly converged to a rod molybdenum target of 2.0 mm in diameter by the electric field in the x-ray tube, weakly ionized linear plasma, which consists of molybdenum ions and electrons, forms by target evaporation. At a charging voltage of 55 kV, the maximum tube voltage was almost equal to the charging voltage of the main condenser, and the peak current was about 20 kA. When the charging voltage was increased, the linear plasma formed, and the K-series characteristic x-ray intensities increased. The K lines were quite sharp and intense, and hardly any bremsstrahlung rays were detected. The x-ray pulse widths were approximately 700 ns, and the time-integrated x-ray intensity had a value of approximately 35 μC/kg at 1.0 m from the x-ray source with a charging voltage of 50 kV. (author)

  10. Effect of continuous irradiation with low dose X-rays on the reproductive complications in male diabetic rats

    International Nuclear Information System (INIS)

    Zhao Hongguang; Xu Songbai; Li Pengwu; Wang Zhicheng; Lin Chenghe; Gong Shouliang

    2009-01-01

    Objective: To explore the effects of 75 mGy irradiation on the apoptosis of spermatogenic cells and antioxidant capacity of serum and testis and hormone levels in male rats with diabetes mellitus (DM). Methods: Rats were injected intraperitoneally with streptozotocin (STZ) to develop diabetes. The diabetic rats were irradiated with 75 mGy X-rays every other day for 4 weeks. Their survival rate and body weight were recorded 12 weeks after development of diabetes. The apeptosis percentage of germ cells was measured with flow cytometry and TUNEL method. The changes of anti-oxidation and gonadal hormone levels in serum and testis were measured with kits. Results: After the rats suffered from diabetes for 12 weeks, the survival rate in DM group was 25% (6/24), 100% in normal control group (16116). The survival rate in 75 mGy + DM group (9/16,56.25%) was obviously higher than that in the DM group (χ 2 = 4.00,P < 0.05). Meanwhile, the percentage of apaptotic spermatogenic cells in the diabetic rats was significantly larger than those in the normal control and irradiation groups (F = 5.496, P < 0.05). MDA and NO levels in serum and testis of diabetic rats were higher in varying degrees than that in the normal control, while the serum and testis MDA content in the 75 mGy + DM group were lower than those in the DM group especially in the testis (F = 10.644, P < 0.01). 75 mGy X-ray irradiation decreased NO content in the diabetic rats serum significantly (F = 14.379, P < 0.05) and increased NOS activity and TS, FSH level (F = 9.676, 43.194 and 5.282, respectively, P < 0.05 and P < 0.01). Conclusions: LDR could decrease the MDA level and NO content, and increase the antioxidant enzyme activity and TS and FSH levels in testis and serum of diabetic rats. (authors)

  11. Effects of X-ray irradiation on the microbial growth and quality of flue-cured tobacco during aging

    International Nuclear Information System (INIS)

    Wang, J.J.; Xu, Z.C.; Fan, J.L.; Wang, Y.; Tian, Z.J.; Chen, Y.T.

    2015-01-01

    X-ray irradiation was evaluated for improving microbial safety and the quality of flue-cured tobacco during aging. Tobacco samples were irradiated at doses of 0, 1, 2, 3 and 5 kGy and stored for 12 months under normal storage conditions or in a high-humidity (RH>70%) room. Microbiological data indicated that the population of total aerobic bacteria was significantly decreased with increasing irradiation doses. In particular, a dose of 2 kGy was effective for the decontamination of fungi from the tested samples, with a 0.93 log CFU/g reduction for bacteria. The control and 1 kGy X-ray treated tobacco samples were became rotted and moldy after the 12th month, whereas those treated with 2, 3 and 5 kGy had no detectable mold during 12 months of storage at high humidity. Chemical measurements showed that irradiation up to 3 kGy did not affect the total nitrogen, nicotine, reducing and total sugars, ratio of total nitrogen to nicotine and sugar-to-nicotine ratio. Furthermore, sensory evaluation results also showed that X-ray irradiation did not affect sensory scores with irradiation at a dose <3 kGy. Based on these results, X-ray irradiation dose in the range of 2–3 kGy is recommended for the decontamination of fungi from flue-cured tobacco. - Highlights: • 2 kGy dose improved sufficiently the microbial safety of flue-cured tobacco. • The doses up to 3 kGy did not affect the chemical components. • A dose <3 kGy had no effect on sensory scores. • The recommended dose to irradiated flue-cured tobacco is the range of 2–3 kGy

  12. Techunique to depress seeds formation in small sized watermelon [Citrullus lanatus] by using pollen irradiated with soft X-rays

    International Nuclear Information System (INIS)

    Tajiri, K.; Ishida, T.

    2005-01-01

    Pollen irradiated soft X-rays is effective to depress seed formation in fruits of watermelon. In this investigation, it's effect are disucussed on some varieties of small sized water melon on semi-focing and retarding culture. Results are followed; The radiation of soft X-rays to pollen gave less seeds formation in fruits of wide varieties on both cropping season. The fruit setting was normal on the case of using irradiated pollen, and the growth and quality of fruits were equal or better than that of triploid variety of watermelon. The size of emty seeds remained in fruit was big in the variety whitch had originally big size seeds. On variety comparison under two cropping season. 'hitorijime' , 'summerkids' and ' himekannsen' showed excellent quality and less-formation of residual seeds in their fruits. To determine optimum level of soft X-rays irradiation, three levels of irradiation intensity were te sted. Irradiation intensity to pollen did not affect to the furit setting and the growth of fruit. B ut sugarcontent in fruit was generally higher than that of no-treatment. The effect of radiation int ensity to formation of seeds was different on cropping season. The optimum intensity was 1600Gy on r etarding culture. On semi-forcing culture, depressive effect on seeds formation by soft X-rays irrad iation was incresed as the increment of irradiation intensity between 0 to 800Gy, but irradiation av obe 1600Gy gave opposite result. Then optimum irradiation level is 800-1200Gy

  13. ROS enhancement by silicon nanoparticles in X-ray irradiated aqueous suspensions and in glioma C6 cells

    Energy Technology Data Exchange (ETDEWEB)

    David Gara, Pedro M. [CITOMA, Fundacion Avanzar, Instituto de Terapia Radiante S.A., CIO La Plata (Argentina); Garabano, Natalia I. [University of Buenos Aires, Departamento de Quimica Biologica, Facultad de Ciencias Exactas y Naturales, UBA (Argentina); Llansola Portoles, Manuel J. [UNLP, INIFTA, Departamento de Quimica, Facultad de Ciencias Exactas (Argentina); Moreno, M. Sergio [Centro Atomico Bariloche (Argentina); Dodat, Diego; Casas, Oscar R. [CITOMA, Fundacion Avanzar, Instituto de Terapia Radiante S.A., CIO La Plata (Argentina); Gonzalez, Monica C., E-mail: gonzalez@inifta.unlp.edu.ar [UNLP, INIFTA, Departamento de Quimica, Facultad de Ciencias Exactas (Argentina); Kotler, Monica L., E-mail: kotler@qb.fcen.uba.ar [University of Buenos Aires, Departamento de Quimica Biologica, Facultad de Ciencias Exactas y Naturales, UBA (Argentina)

    2012-03-15

    The capability of silicon nanoparticles to increase the yield of reactive species upon 4 MeV X-ray irradiation of aqueous suspensions and C6 glioma cell cultures was investigated. ROS generation was detected and quantified using several specific probes. The particles were characterized by FTIR, XPS, TEM, DLS, luminescence, and adsorption spectroscopy before and after irradiation to evaluate the effect of high energy radiation on their structure. The total concentration of O{sub 2}{sup Bullet -}/HO{sub 2}{sup Bullet}, HO{sup Bullet}, and H{sub 2}O{sub 2} generated upon 4-MeV X-ray irradiation of 6.4 {mu}M silicon nanoparticle aqueous suspensions were on the order of 10 {mu}M per Gy, ten times higher than that obtained in similar experiments but in the absence of particles. Cytotoxic {sup 1}O{sub 2} was generated only in irradiation experiments containing the particles. The particle surface became oxidized to SiO{sub 2} and the luminescence yield reduced with the irradiation dose. Changes in the surface morphology did not affect, within the experimental error, the yields of ROS generated per Gy. X-ray irradiation of glioma C6 cell cultures with incorporated silicon nanoparticles showed a marked production of ROS proportional to the radiation dose received. In the absence of nanoparticles, the cells showed no irradiation-enhanced ROS generation. The obtained results indicate that silicon nanoparticles of <5 nm size have the potential to be used as radiosensitizers for improving the outcomes of cancer radiotherapy. Their capability of producing {sup 1}O{sub 2} upon X-ray irradiation opens novel approaches in the design of therapy strategies.

  14. Enhanced response of the fricke solution doped with hematoporphyrin under X-rays irradiation

    Directory of Open Access Journals (Sweden)

    Carlos Austerlitz

    2008-04-01

    Full Text Available The vials filled with Fricke solutions were doped with increasing concentrations of Photogem®, used in photodynamic therapy. These vials were then irradiated with low-energy X-rays with doses ranging from 5 to 20 Gy. The conventional Fricke solution was also irradiated with the same doses. The concentration of ferric ions for the Fricke and doped-Fricke irradiated solutions were measured in a spectrophotometer at 220 to 340 nm. The results showed that there was an enhancement in the response of the doped-Fricke solution, which was proportional to the concentration of the photosensitizer. The use of such procedure for studying the radiosensitizing property of photosensitizers based on the production of free radicals is also discussed.Tubos de ensaio foram preenchidos com a solução Fricke dopada com Fotogem® em concentrações crescentes; essa hemotoporfirina é utilizada na terapia fotodinâmica. Esses tubos foram irradiados com doses de 5 a 20 Gy. A solução Fricke convencional também foi irradiada com as mesmas doses. As concentrações de íons férricos nas soluções Fricke convencional e dopadas irradiadas foram medidas num espectrofotômetro com comprimento de onda entre 220 e 340 nm. Os resultados mostraram que quando comparado o Fricke convencional com o Fricke dopado irradiado, as amostras dopadas demonstraram um aumento na resposta da dose absorvida que é proporcional a concentração do Photogem® na solução Fricke. Concluímos que esse procedimento pode ser utilizado para propósitos de dosimetria na terapia com radiossensibilizadores.

  15. Neonatal anthropometrics and body composition in obese children investigated by dual energy X-ray absorptiometry

    DEFF Research Database (Denmark)

    Lausten-Thomsen, Ulrik; Nielsen, Tenna Ruest Haarmark; Thagaard, Ida Näslund

    2014-01-01

    index (BFMI), and fat free mass index (FFMI) in obese children and the preceding in utero conditions expressed by birth weight, birth length, and birth weight for gestational age. The study cohort consisted of 776 obese Danish children (median age 11.6 years, range 3.6-17.9) with a mean Body Mass Index......UNLABELLED: Epidemiological and animal studies have suggested an effect of the intrauterine milieu upon the development of childhood obesity. This study investigates the relationship between body composition measured by dual energy X-ray absorptiometry expressed as body fat percent, body fat mass...... obesity treatment to be significantly correlated with both birth weight and birth weight for gestational age. CONCLUSION: These results indicate a prenatal influence upon childhood obesity. Although there are currently no sufficient data to suggest any recommendations to pregnant women, it is possible...

  16. Evaluation of body simulator for chest and abdomen in digital X-ray equipment

    International Nuclear Information System (INIS)

    Soares, Sidney S.; Cardoso, Gabriela P.; Oliveira, Giovanni Antônio P.; Batista, Adriana S.M.; Pereira, Esther Lorrayne M.

    2017-01-01

    The use of body simulators to control the quality of X-ray images is a practice that guarantees the control of essential parameters for diagnosis by the technique. The evolution of the equipment, between the analogue, digital computerized radiology (CR) and direct radiography (DR), requires evaluation of the equivalence in grayscale, of simulators, for an adjustment according to the specific technology of obtaining the image. In this sense, the present work presents the evaluation of a body simulator with regard to the representation of mean values of signal, noise and contrast obtained in chest radiographs and panoramic of the abdomen. For the thorax the cardiac region was considered as simulation target and for the abdomen simulation of the liver and small intestine. We used a retrospective study of images obtained with X-ray equipment - CR system, in which the images were studied using the ImageJ program, generating a data catalog. These were subsequently compared with those obtained experimentally using gel filled polymer body simulator. For the validation of the simulator, it was observed the gel equivalence of filling of the polymer box required to reach the image parameters of the cataloged radiographs. The results are discussed as to the physical principles of radiation interaction with biological and equivalent tissues

  17. Efficient soft x-ray sources from laser-irradiated gold foam targets with well-controlled impurities

    Science.gov (United States)

    Dong, Yunsong; Yang, Jiamin; Song, Tianming; Shang, Wanli; Zhang, Lu; Huang, Chengwu; Zhu, Tuo; Zhang, Wenhai; Li, Zhichao; Zhan, Xiayu; Du, Huabing; Wang, Feng; Liu, Shenye; Jiang, Shaoen; Ding, Yongkun

    2018-01-01

    As an important x-ray source, enhancement of x-ray emissions from laser-produced plasmas is significant for various applications. Due to less expanding kinetic loss, gold foam with low initial density can have an enhanced x-ray conversion efficiency compared with solid-density gold. However, low-Z impurities within gold foam targets will diminish the enhancement remarkably, and should be tightly controlled. This paper presents an experimental study of a high brightness laser plasma soft x-ray source, based on a 0.36 g cm-3 gold foam target with negligible impurities irradiated by nanosecond laser pulses with power density around 3  ×  1014 W cm-2 at the Shenguang II laser facility. A conversion efficiency, from multi-eV to multi-keV, of 51.2 % is achieved in the x-ray emissions—about 21% relative enhancement compared with a solid-density gold target, and the highest conversion efficiency for Au foam planar targets yet. Good agreement has been achieved between the semi-analytical model prediction and the experimental results.

  18. X-ray diffraction pattern and relative crystallinity of irradiated arrowroot starch

    Energy Technology Data Exchange (ETDEWEB)

    Barroso, Aline G.; Garcia, Rafael H.L.; Del Mastro, Nelida L., E-mail: nlmastro@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    After cereals, tubers and roots are the major source of starch for food and industrial uses. Arrowroot refers to any plant of the genus Marantha, but the term is most commonly used to describe the easily digested starch obtained from the rhizomes of Marantha arundinacae. The rhizomes of this herbaceous plant contain about 20% of starch. As few studies exist on arrowroot starch, the objective of this preliminary work was to study the X-ray diffraction patterns (XRD) patterns of arrowroot starch when treated by γ-radiation with doses up to 15 kGy in a {sup 60}Co source. The XRD patterns of the arrowroot starch exhibited A-type crystalline arrangements with strong peaks at approximately 15º, 17º, 18º and 23º (2θ). A slight increase of diffractogram peaks intensity was noticed after the irradiation process. The crystallinity index was calculated using Bruker DIFFRAC.EVA version 4.2 software. Relative crystallinity seems to increase with radiation doses, and this effect is more noticeable at low doses. That can be attributed to different radiation sensitivity among the amorphous and crystalline regions of the arrowroot starch molecule. Present results will contribute to elucidate the behavior under radiation treatment of this starchy component increasingly employed by the food industry. (author)

  19. X-ray diffraction pattern and relative crystallinity of irradiated arrowroot starch

    International Nuclear Information System (INIS)

    Barroso, Aline G.; Garcia, Rafael H.L.; Del Mastro, Nelida L.

    2017-01-01

    After cereals, tubers and roots are the major source of starch for food and industrial uses. Arrowroot refers to any plant of the genus Marantha, but the term is most commonly used to describe the easily digested starch obtained from the rhizomes of Marantha arundinacae. The rhizomes of this herbaceous plant contain about 20% of starch. As few studies exist on arrowroot starch, the objective of this preliminary work was to study the X-ray diffraction patterns (XRD) patterns of arrowroot starch when treated by γ-radiation with doses up to 15 kGy in a 60 Co source. The XRD patterns of the arrowroot starch exhibited A-type crystalline arrangements with strong peaks at approximately 15º, 17º, 18º and 23º (2θ). A slight increase of diffractogram peaks intensity was noticed after the irradiation process. The crystallinity index was calculated using Bruker DIFFRAC.EVA version 4.2 software. Relative crystallinity seems to increase with radiation doses, and this effect is more noticeable at low doses. That can be attributed to different radiation sensitivity among the amorphous and crystalline regions of the arrowroot starch molecule. Present results will contribute to elucidate the behavior under radiation treatment of this starchy component increasingly employed by the food industry. (author)

  20. Restoring efficiency of hemopoietic cell transplantation in a mouse lethally irradiated by a total exposure to X rays

    International Nuclear Information System (INIS)

    Doria, Gino

    1959-10-01

    This research thesis reports the study of possibility of treatments (or restoration) of a mouse which has been submitted to a lethal dose of X rays. More particularly, the author compared the restoring efficiency of bone marrow and fetal liver injected in a mouse which had been lethally irradiated by a total exposure to X rays. He also studied the functional status of the hemopoietic graft, and the emergence of the secondary disease in mice which had been as well lethally irradiated and then restored by injection of bone marrow and fetal liver. The author then addressed the influence of the induction of immune tolerance of the host with respect to the donor on the survival of a mouse lethally irradiated and restored by homologue bone marrow [fr

  1. Sister chromatid exchanges in X-ray irradiated blood lymphocytes from patients with hereditary diseases with radioresistant DNA synthesis

    International Nuclear Information System (INIS)

    Pleskach, N.M.; Andriadze, M.I.; Mikhel'son, V.M.; Zhestyanikov, V.D.

    1988-01-01

    X-ray irradiation induced sister chromatid exchanges (SCE) in blood lymphocytes from patient with Down's syndrome and adult progeria (in both the cases radioresistant DNA synthesis takes place). In normal lymphocytes (in which ionizing radiation inhibits the replicative synthesis of DNA) the rate of SCE rises with the rise of radiation dose. Thus, the rate of SCE in X-ray irradiated lymphocytes is in reverse dependence with radioresistance of replicative synthesis of DNA. The data obtained are explained in accordance with the replicative hypothesis of the SCE nature (Painter, 1980a): in cells of patients with Down's syndrome, xeroderma pigmentosum from 2 and progeria of adults the time of existence of partly replicated clusters of replicons is decreased due to radioresistant replicative synthesis of DNA, but the presence of partly replicated clusters of replicons in necessary for SCE formation. Therefore the rate of SCF in X-irradiated cells of these patients decreases

  2. Effects of X-ray irradiation on expression of Pokemon gene in A549 cells of human lung adenocarcinoma

    International Nuclear Information System (INIS)

    Wang Lu; Zou Yue; Jiang Qisheng; Li Wei; Song Xiujun; Zhou Xiangyan; Wang Cuilan

    2011-01-01

    Objective: To study the dose-and time-effects of X-ray irradiation on the expression of Pokemon gene in A549 cells of human lung adenocarcinoma. Methods: A549 cells were cultured in vitro and exposed to X-rays with the doses of 2, 4, 6 and 8 Gy, respectively. Untreated A549 cells were used as control group. The relative levels of Pokemon mRNA expression in the cells were detected by using quantitative real-time PCR at 2, 4, 8, 12, 24, 48 and 72 h after irradiation. Results: The Pokemon mRNA expression levels decreased in the early period after irradiation (except 2 and 4 h after irradiation in 2 Gy group) and then increased in the later stage (48 h after irradiation) with significant statistical differences at the most time points in comparison with the control group (t=3.40-154.76, P<0.05). Conclusions: Higher doses of X-rays may degrade the expression of Pokemon mRNA in the human A549 cells and induce apoptosis in the early period, hut also may upgrade its expression in the later period, which might be correlated with the cell cycle regulation and DNA damage repair in the A549 cells. (authors)

  3. Anatomical alterations of Phaseolus vulgaris L. mature leaves irradiated with X-rays.

    Science.gov (United States)

    De Micco, V; Arena, C; Aronne, G

    2014-01-01

    The cultivation of higher plants in Space involves not only the development of new agro-technologies for the design of ecologically closed Space greenhouses, but also understanding of the effects of Space factors on biological systems. Among Space factors, ionising radiation is one of the main constraints to the growth of organisms. In this paper, we analyse the effect of low-LET radiation on leaf histology and cytology in Phaseolus vulgaris L. plants subjected to increasing doses of X-rays (0.3, 10, 50, 100 Gy). Leaves irradiated at tissue maturity were compared with not-irradiated controls. Semi-thin sections of leaves were analysed through light and epi-fluorescence microscopy. Digital image analysis was applied to quantify anatomical parameters, with a specific focus on the occurrence of signs of structural damage as well as alterations at subcellular level, such as the accumulation of phenolic compounds and chloroplast size. Results showed that even at high levels of radiation, general anatomical structure was not severely perturbed. Slight changes in mesophyll density and cell enlargement were detected at the highest level of radiation. However, at 100 Gy, higher levels of phenolic compounds accumulated along chloroplast membranes: this accompanied an increase in number of chloroplasts. The reduced content of chlorophylls at high levels of radiation was associated with reduced size of the chloroplasts. All data are discussed in terms of the possible role of cellular modifications in the maintenance of high radioresistance and photosynthetic efficiency. © 2013 German Botanical Society and The Royal Botanical Society of the Netherlands.

  4. Effects of X-ray irradiation on the expression of Pokemon gene in human lung adenocarcinoma cell line

    International Nuclear Information System (INIS)

    Liang Xiaofang; Zou Yue; Wang Lu; Jiang Qisheng; Li Fengsheng

    2012-01-01

    Objective: To study the dose and time effects of X-ray radiation on the expression of Pokemon gene and protein in human lung adenocarcinoma cell line A 549 . Methods: A 549 cells was exposed to different doses of X-ray (2, 4, 6 and 8 Gy), and the expression of Pokemon mRNA and protein of the cells was detected by using Quantitative real-time PCR and western-blotting at 2, 4, 8, 12, 24, and 48 h after irradiation. 3-( 4, 5-Dimethylthiazole-2-yl )-2, 5-diphenyltetrazolium bromide was used to detect the proliferation of A 549 cells at 1, 2, 3, 4, and 5 d after 2 Gy X-ray irradiation. The mock treated A 549 cells were used as the control. Results: The expression of Pokemon mRNA trended to decrease after irradiated with 4, 6 and 8 Gy in the earlier period and increased in the later period with statistical difference at the most time points (t =3.40 -154.76, P =0.000 -0.041). The expression of Pokemon protein trended to increase and reached the peak at 8 h after irradiated of 2, 4, 6 and 8 Gy with statistical difference at the most time points (t =4.18 - 89.64, P =0.000 - 0.039). Compared with the control, the proliferation of A 549 cells was significantly inhibited during 3 to 5 d after irradiation of 2 Gy (t =2.34 - 18.19, P =0.000 -0.040). Conclusions: X-ray irradiation may increase the expression of Pokemon mRNA and protein in A 549 cells, which might be correlated with radiation-resistance of A 549 cells. (authors)

  5. EFFECT OF POLYPHENOLIC COMPLEX FROM WINE ON RATS ANTIOXIDANT ENZYMES ACTIVITY AT X-RAY IRRADIATION LOW DOSES

    Directory of Open Access Journals (Sweden)

    U. V. Datsyuk

    2014-04-01

    Full Text Available It is shown that the consumption of natural polyphenolic complex from grape wine in drinking water in the daily dose 2.5 ± 1.1 mg polyphenols/kg body mass of rats during the 10 day before exposure to radiation leads to increased of superoxide dismutase and gluthathione reductase activities in peripheral blood on 24 and 48 hours after full body X-ray irradiation (30 cGy. The of catalase, gluthathione peroxidase activities and the of the reactive thiobarbituric acid substances content in total lysates of peripheral blood within 72 hours after exposure are comparable to those in control rats. Marked decreased of catalase and superoxide dismutase activities at 24, 48 and 24 hours, respectively, was observed after exposure to ionizing radiation and increased content of lipid peroxidation products in all above mentioned time points. The decreased of superoxide dismutase and gluthathione peroxidase activities in lysates of rats aorta at 48 hour and increased content of the reactive thiobarbituric acid substances during 72 hours after radiation exposure were observed. The consumption of polyphenolic complex from wine did not change the superoxide dismutase and catalase activities in lysates of aorta rats treated with ionizing radiation, whereas gluthathione reductase and gluthathione peroxidase activities was increased during 72 hours after radiation influence. The content of TBA reactive substances was significantly decreased in lysates of aorta rats that were exposed to radiation and polyphenols of grape wine, compared with those of animals that were exposed to radiation alone.

  6. Evaluation of components of X-ray irradiated 7-valent pneumococcal conjugate vaccine and pneumococcal vaccine polyvalent and X-ray and gamma-ray irradiated acellular pertussis component of DTaP vaccine products

    International Nuclear Information System (INIS)

    May, J.C.; Rey, L.; Lee, C.-J.; Arciniega, Juan

    2004-01-01

    Samples of pneumococcal vaccine polyvalent, 7-valent pneumococcal conjugate vaccine, and two different diphtheria and tetanus toxoids and acellular pertussis vaccines adsorbed were irradiated with X-rays and/or gamma-rays (Co-60). Mouse IgG and IgM antibody responses (ELISA) for types 9V, 14, 18C, and 19F pneumococcal polysaccharides and conjugates indicated that the polysaccharides were more tolerant of the radiation than the conjugates. The mouse antibody response for the detoxified pertussis toxin (PT) antigen, filamentous hemagglutinin antigen (FHA), pertactin (PRN), and fimbriae types 2 and 3 (FIM) antigens for the appropriate vaccine type indicated that the antibody response was not significantly changed in the 25 kGy X-ray irradiated vaccines frozen in liquid nitrogen compared to the control vaccine

  7. Evaluation of components of X-ray irradiated 7-valent pneumococcal conjugate vaccine and pneumococcal vaccine polyvalent and X-ray and gamma-ray irradiated acellular pertussis component of DTaP vaccine products

    Energy Technology Data Exchange (ETDEWEB)

    May, J.C. E-mail: may@cber.fda.gov; Rey, L. E-mail: louis.rey@bluewin.ch; Lee, C.-J.; Arciniega, Juan

    2004-10-01

    Samples of pneumococcal vaccine polyvalent, 7-valent pneumococcal conjugate vaccine, and two different diphtheria and tetanus toxoids and acellular pertussis vaccines adsorbed were irradiated with X-rays and/or gamma-rays (Co-60). Mouse IgG and IgM antibody responses (ELISA) for types 9V, 14, 18C, and 19F pneumococcal polysaccharides and conjugates indicated that the polysaccharides were more tolerant of the radiation than the conjugates. The mouse antibody response for the detoxified pertussis toxin (PT) antigen, filamentous hemagglutinin antigen (FHA), pertactin (PRN), and fimbriae types 2 and 3 (FIM) antigens for the appropriate vaccine type indicated that the antibody response was not significantly changed in the 25 kGy X-ray irradiated vaccines frozen in liquid nitrogen compared to the control vaccine.

  8. Characteristic x-ray emission from undermines plasmas irradiated by ultra-intense lasers

    Energy Technology Data Exchange (ETDEWEB)

    Niemann, Christoph [Univ. of California, Los Angeles, CA (United States)

    2012-05-05

    Between FY09 and FY11 we have conducted more than a dozen three-week experimental campaigns at high-power laser facilities around the world to investigate laser-channeling through x-ray and optical imaging and the conversion from laser-energy to xrays. We have performed simultaneous two-wavelength x-ray imaging (K-alpha and He-alpha) to distinguish the hot-plasma region (hot-spot) from the laser-produced electrons (K-alpha). In addition, we have initiated a new collaboration with SNL and have performed first shots on the 100 TW beamlet chamber to commission a fast x-ray streak camera to be used to investigate the temporal evolution of our K-alpha sources. We also collaborated on campaigns at the Rutherford Appleton Laboratory (UK) and the LANL Trident laser to employ laser produced x-ray sources for Thomson scattering off dense matter.

  9. Mortality and sterility induced in Piophila casei by x-ray and neutron irradiation

    International Nuclear Information System (INIS)

    Sacchi, L.; Gasperi, G.; Grigolo, A.; Caprotti, M.; Pinelli, T.; Altieri, S.

    1977-01-01

    Different doses of neutrons and X-rays were given to 5-day-old pupae of Piophila casei L. (Diptera, Piophilidae), just before their emergence. The mortality and sterility induced by the different types of radiation were measured. Neutrons are more effective than X-rays in provoking lethal lesions in somatic cells. Females are more resistant than males to the sterilizing action of neutrons, the relative biological efficiency of neutrons being 6 and 3.5, respectively

  10. Assessment of body composition by dual-energy X-ray absorptiometry, bioimpedance analysis and anthropometrics in children

    DEFF Research Database (Denmark)

    Tompuri, Tuomo T; Lakka, Timo A; Hakulinen, Mikko

    2015-01-01

    We compared InBody720 segmental multifrequency bioimpedance analysis (SMF-BIA) with Lunar Prodigy Advance dual-energy X-ray absorptiometry (DXA) in assessment of body composition among 178 predominantly prepubertal children. Segmental agreement analysis of body compartments was carried out...

  11. Measuring body composition in overweight individuals by dual energy x-ray absorptiometry

    International Nuclear Information System (INIS)

    Brownbill, Rhonda A; Ilich, Jasminka Z

    2005-01-01

    Dual energy x-ray absorptiometry (DXA) is widely used for body composition measurements in normal-weight and overweight/obese individuals. The limitations of bone densitometers have been frequently addressed. However, the possible errors in assessing body composition in overweight individuals due to incorrect positioning or limitations of DXA to accurately assess both bone mineral density and body composition in obese individuals have not received much attention and are the focus of this report. We discuss proper ways of measuring overweight individuals and point to some studies where that might not have been the case. It appears that currently, the most prudent approach to assess body composition of large individuals who cannot fit under the scanning area would be to estimate regional fat, namely the regions of thigh and/or abdomen. Additionally, using two-half body scans, although time consuming, may provide a relatively accurate measurement of total body fat, however, more studies using this technique are needed to validate it. Researchers using bone densitometers for body composition measurements need to have an understanding of its limitations in overweight individuals and address them appropriately when interpreting their results. Studies on accuracy and precision in measurements of both bone and soft tissue composition in overweight individuals using available densitometers are needed

  12. Interspecific transfer of only part of genome by fusion between non-irradiated protoplasts of Nicotiana glauca and X-ray irradiated protoplasts of N. Langsdorffii

    International Nuclear Information System (INIS)

    Itoh, K.; Futsuhara, Y.

    1983-01-01

    To transfer only part of genome, X-ray irradiated suspension cell protoplasts of N. langsdorffii were fused with suspension cell protoplasts of N. glauca by polyethylene glycol. Somatic hybrid calli were selected by the growth in the hormone-free medium. Some of somatic hybrid calli from fusion with irradiated protoplasts indicated the loss of small subunit polypeptide of fraction 1 protein which was coded by N. langsdorffii nuclear DNA. Cytological analysis provided an information on significant decrease of chromosomes in somatic hybrid calli from fusion with irradiated protoplasts, compared with the somatic hybrid calli from fusion with non-irradiated protoplasts. In addition, isozyme analysis revealed that somatic hybrid calli from fusion with irradiated protoplasts lost particular bands of N. langsdorffli. These results demonstrate the tranfer of only part of genome from N, langsdorffii to N, glauca by fusion with X-ray irradiated protoplasts

  13. X-Ray Photoelectron Spectroscopy of Stabilized Zirconia Films with Embedded Au Nanoparticles Formed under Irradiation with Gold Ions

    Science.gov (United States)

    Zubkov, S. Yu.; Antonov, I. N.; Gorshkov, O. N.; Kasatkin, A. P.; Kryukov, R. N.; Nikolichev, D. E.; Pavlov, D. A.; Shenina, M. E.

    2018-03-01

    Nanosized films of stabilized zirconia with Au nanoparticles formed by implanting Au ions are studied by X-ray photoelectron spectroscopy and transmission electron microscopy. The effect of irradiation of films with Au ions and postimplantation annealing on the distribution of chemical elements and zirconium- containing ZrO x compounds over the depth of the films is studied. Based on the data on the dimensional shift of the Au 4 f photoelectron line, the average value of the nanoparticle size is determined.

  14. Pediatric body composition analysis with dual-energy X-ray absorptiometry

    Energy Technology Data Exchange (ETDEWEB)

    Helba, Maura; Binkovitz, Larry A. [Nationwide Children' s Hospital, Department of Radiology, Columbus, OH (United States)

    2009-07-15

    Pediatric applications of body composition analysis (BCA) have become of increased interest to pediatricians and other specialists. With the increasing prevalence of morbid obesity and with an increased awareness of anorexia nervosa, pediatric specialists are utilizing BCA data to help identify, treat, and prevent these conditions. Dual-energy X-ray absorptiometry (DXA) can be used to determine the fat mass (FM) and lean tissue mass (LTM), as well as bone mineral content (BMC). Among the readily available BCA techniques, DXA is the most widely used and it has the additional benefit of precisely quantifying regional FM and LTM. This review evaluates the strengths and limitations of DXA as a pediatric BCA method and considers the utilization of DXA to identify trends and variations in FM and LTM measurements in obese and anorexic children. (orig.)

  15. Pediatric body composition analysis with dual-energy X-ray absorptiometry

    International Nuclear Information System (INIS)

    Helba, Maura; Binkovitz, Larry A.

    2009-01-01

    Pediatric applications of body composition analysis (BCA) have become of increased interest to pediatricians and other specialists. With the increasing prevalence of morbid obesity and with an increased awareness of anorexia nervosa, pediatric specialists are utilizing BCA data to help identify, treat, and prevent these conditions. Dual-energy X-ray absorptiometry (DXA) can be used to determine the fat mass (FM) and lean tissue mass (LTM), as well as bone mineral content (BMC). Among the readily available BCA techniques, DXA is the most widely used and it has the additional benefit of precisely quantifying regional FM and LTM. This review evaluates the strengths and limitations of DXA as a pediatric BCA method and considers the utilization of DXA to identify trends and variations in FM and LTM measurements in obese and anorexic children. (orig.)

  16. Synchrotron topographic evaluation of strain around craters generated by irradiation with X-ray pulses from free electron laser with different intensities

    Czech Academy of Sciences Publication Activity Database

    Wierzchowski, W.; Wieteska, K.; Sobierajski, R.; Klinger, D.; Pelka, J.; Zymierska, D.; Paulmann, C.; Hau-Riege, S.P.; London, R.A.; Graf, A.; Burian, Tomáš; Chalupský, Jaromír; Gaudin, J.; Krzywinski, J.; Moeller, S.; Messerschmidt, M.; Bozek, J.; Bostedt, C.

    2015-01-01

    Roč. 364, Dec (2015), s. 20-26 ISSN 0168-583X Institutional support: RVO:68378271 Keywords : x-ray free electron laser * soft x-ray lasers * irradiation with femtosecond pulses * silicon Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 1.389, year: 2015

  17. X-ray diffraction studies of 145MeV proton-irradiated AlBeMet 162

    Directory of Open Access Journals (Sweden)

    Mohamed Elbakhshwan

    2016-08-01

    Full Text Available AlBeMet 162 (Materion Co., formerly Brush Wellman has been irradiated with 145MeV protons up to 1.2×1020cm−2 fluence, with irradiation temperatures in the range of 100–220°C. Macroscopic post-irradiation evaluation on the evolution of mechanical and thermal properties was integrated with a comprehensive X-ray- diffraction study using high-energy monochromatic and polychromatic X-ray beams, which offered a microscopic view of the irradiation damage effects on AlBeMet. The study confirmed the stability of the metal–matrix composite, its resistance to proton damage, and the continuing separation of the two distinct phases, fcc aluminum and hcp beryllium, following irradiation. Furthermore, based on the absence of inter-planar distance change during proton irradiation, it was confirmed that the stacking faults and clusters on the Al (111 planes are stable, and thus can migrate from the cascade region and be absorbed at various sinks. XRD analysis of the unirradiated AlBeMet 162 showed clear change in the texture of the fcc phase with orientation especially in the Al (111 reflection which exhibits a “non-perfect” six-fold symmetry, implying lack of isotropy in the composite.

  18. Influence of x-ray irradiation on the proliferative ability of the germinal layer cells of Echinococcus multilocularis

    International Nuclear Information System (INIS)

    Ohnishi, Kenji

    1986-01-01

    Influence of X-ray irradiation on the proliferative ability of the germinal layer cells of larval Echinococcus multilocularis was studied by using small sterile hydatids containing vesicles composed of a non-cellular laminated layer and a cellular germinal layer. The small sterile hydatids were irradiated by X-ray at dose levels of 5,000, 15,000, 25,000, 35,000, 45,000 or 55,000 R and implanted into the peritoneal cavity of Chinese hamsters. Fully developed hydatids were recognized in all cases irradiated at up to 35,000 R, when assessed 113 days after implantation. At 45,000 R, 2 out of 6 animals showed small, fully developed hydatids. No such hydatid was found in the other 4 animals nor in any of the animals implanted with hydatids irradiated at 55,000 R. No structural differences were observed between fully developed hydatids originating from the irradiated and non-irradiated small hydatids. These results indicate that the tolerance limit of the germinal layer cells is between 45,000 R and 55,000 R. (author)

  19. Irradiation temperature determination and study of local overheating of fuel cans in austenitic steel by X-ray diffraction

    International Nuclear Information System (INIS)

    Rousset, P.; Cadalbert, R.

    1982-09-01

    The great advantage is demonstrated of measuring the widths of X ray diffraction lines on fast neutron irradiated austenitic steel cladding, for studying (1) the thermic shape of fuel rods and any overheating that might occur and (2) for measuring irradiation temperatures in capsules. This very sensitive method is easy to use on a counter diffraction meter, in a shielded cell, in conjunction with a calculator and an automatic sample holder, and enables temperature distribution charts to be quickly plotted. It is also extensively applicable to other components of the core such as hexagonal tubes, control rods, etc [fr

  20. Assessing Body Composition of Children and Adolescents Using Dual-Energy X-Ray Absorptiometry, Skinfolds, and Electrical Impedance

    Science.gov (United States)

    Mooney, Angela; Kelsey, Laurel; Fellingham, Gilbert W.; George, James D.; Hager, Ron L.; Myrer, J. William; Vehrs, Pat R.

    2011-01-01

    To determine the validity and reliability of percent body fat estimates in 177 boys and 154 girls between 12-17 years of age, percent body fat was assessed once using dual-energy X-ray absorptiometry and twice using the sum of two skinfolds and three bioelectrical impedance analysis devices. The assessments were repeated on 79 participants on a…

  1. A study of percentage body fat in children via dual energy X-ray absorptiometry (DEXA)

    International Nuclear Information System (INIS)

    Kawano, Shoji; Yagi, Shinichi; Fujino, Mitsuyoshi; Tanaka, Hiroyuki; Morita, Tetsuro; Fukunaga, Masao

    1994-01-01

    Percentage body fat was measured using dual energy X-ray absorptiometry (DEXA), bioelectrical impedance analysis (BIA) and skin fold calipers on 26 children (nine in obesity group, 12 in healthy group and 5 in steroid treated group). Mean percent body fat did not differ significantly between methods in the whole subjects as well as the healthy group and the steroid treated group. However, the mean percent body fat using skin fold caliper was higher for the obesity group than the other two. The measurements of all cases in the obesity group by DEXA were higher than those of BIA. There were high correlations among the percent body fat obtained by each technique. According to the analysis of mean regional percent fat, the percent fat of legs was the highest in the healthy and steroid treated group, while there was no regional difference in the obesity group. It should be possible to classify each case in the obesity group into upper segment and lower segment obesity by DEXA. (author)

  2. A study of percentage body fat in children via dual energy X-ray absorptiometry (DEXA)

    Energy Technology Data Exchange (ETDEWEB)

    Kawano, Shoji; Yagi, Shinichi; Fujino, Mitsuyoshi; Tanaka, Hiroyuki; Morita, Tetsuro; Fukunaga, Masao (Kawasaki Medical School, Kurashiki, Okayama (Japan))

    1994-05-01

    Percentage body fat was measured using dual energy X-ray absorptiometry (DEXA), bioelectrical impedance analysis (BIA) and skin fold calipers on 26 children (nine in obesity group, 12 in healthy group and 5 in steroid treated group). Mean percent body fat did not differ significantly between methods in the whole subjects as well as the healthy group and the steroid treated group. However, the mean percent body fat using skin fold caliper was higher for the obesity group than the other two. The measurements of all cases in the obesity group by DEXA were higher than those of BIA. There were high correlations among the percent body fat obtained by each technique. According to the analysis of mean regional percent fat, the percent fat of legs was the highest in the healthy and steroid treated group, while there was no regional difference in the obesity group. It should be possible to classify each case in the obesity group into upper segment and lower segment obesity by DEXA. (author).

  3. Dual-energy X-ray absorptiometry body composition in patients with secondary osteoporosis.

    Science.gov (United States)

    Messina, Carmelo; Monaco, Cristian Giuseppe; Ulivieri, Fabio Massimo; Sardanelli, Francesco; Sconfienza, Luca Maria

    2016-08-01

    Due to the tight relationship between bone and soft tissues, there has been an increased interest in body composition assessment in patients with secondary osteoporosis as well as other pathological conditions. Dual-energy X-ray absorptiometry (DXA) is primarily devoted to the evaluation of bone mineral status, but continuous scientific advances of body composition software made DXA a rapid and easily available technique to assess body composition in terms of fat mass and lean mass. As a result, the International Society for Clinical Densitometry (ISCD) recently developed Official Positions regarding the use of this technique for body composition analysis. According to ISCD paper, indications are mainly limited to three conditions: HIV patients treated with antiretroviral agents associated with a risk of lipoatrophy; obese patients undergoing treatment for high weight loss; patients with sarcopenia or muscle weakness. Nevertheless, there are several other interesting clinical applications that were not included in the ISCD position paper, such as body composition assessment in patients undergoing organ transplantation, pulmonary disease as well as all those chronic condition that may lead to malnutrition. In conclusion, DXA body composition offers new diagnostic and research possibilities for a variety of diseases; due to its high reproducibility, DXA has also the potential to monitor body composition changes with pharmacological, nutritional or physic therapeutic interventions. ISCD addressed and recommended a list of clinical condition, but the crescent availability of DXA scans and software improvements may open the use of DXA to other indication in the next future. This article provides an overview of DXA body composition indications in the management of secondary osteoporosis and other clinical indications in adults. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. A biosafety evaluation of synchrotron radiation X-ray to skin and bone marrow: single dose irradiation study of rats and macaques.

    Science.gov (United States)

    Lu, Yifan; Tang, Guanghui; Lin, Hui; Lin, Xiaojie; Jiang, Lu; Yang, Guo-Yuan; Wang, Yongting

    2017-06-01

    Very limited experimental data is available regarding the safe dosages related to synchrotron radiation (SR) procedures. We used young rats and macaques to address bone marrow and skin tolerance to various doses of synchrotron radiation. Rats were subjected to 0, 0.5, 2.5, 5, 25 or 100 Gy local SR X-ray irradiation at left hind limb. Rat blood samples were analyzed at 2-90 days after irradiation. The SR X-ray irradiated skin and tibia were sectioned for morphological examination. For non-human primate study, three male macaques were subjected to 0.5 or 2.5 Gy SR X-ray on crus. Skin responses of macaques were observed. All rats that received SR X-ray irradiation doses greater than 2.5 Gy experienced hair loss and bone-growth inhibition, which were accompanied by decreased number of follicles, thickened epidermal layer, and decreased density of bone marrow cells (p X-ray but showed significant hair loss when the dose was raised above 2.5 Gy. The safety threshold doses of SR X-ray for rat skin, bone marrow and macaque skin are between 0.5 and 2.5 Gy. Our study provided essential information regarding the biosafety of SR X-ray irradiation.

  5. Body-weight and chromosome aberrations induced by X-rays in somatic cells of Drosophila melanogaster

    International Nuclear Information System (INIS)

    Marco, A. de; Belloni, M.P.

    1976-01-01

    Body-weight has been shown to influence the final expression of genetic damage by X-rays in Drosophila melanogaster. If larvae of Drosophila were raised up to the third instar in media containing different amounts of the same nutrient and in different conditions of crowding a positive correlation was observed between body-weight and frequency of chromosome aberrations induced by a given dose of X-rays in the somatic cells of their nerve ganglia. This effect, present in both sexes, is most plausibly attributed to a different capacity of big and small larvae for repairing radiation damage. (orig.) [de

  6. Inactivation of Escherichia coli O157:H7 on lettuce, using low-energy X-ray irradiation.

    Science.gov (United States)

    Jeong, Sanghyup; Marks, Bradley P; Ryser, Elliot T; Moosekian, Scott R

    2010-03-01

    Low-energy X-ray irradiation was assessed as a means of eliminating Escherichia coli O157:H7 on lettuce. Round-cut iceberg lettuce samples (2.54-cm diameter) were dip or spot inoculated with a three-strain cocktail of E. coli O157:H7, stored for 24 h at 4 degrees C, and then irradiated at four dose levels up to 0.25 kGy using a prototype low-energy (70 kV) X-ray irradiator. E. coli O157:H7 survivors were quantified by plating on sorbitol MacConkey agar containing cefixime and tellurite. Dip inoculation yielded a D(10)-value of 0.040 +/- 0.001 kGy, which is 3.4 times lower than a previously reported value of 0.136 kGy using gamma radiation. The D(10)-value for E. coli O157:H7 on spot-inoculated samples was 0.078 +/- 0.008 kGy, which is about twice that of dip-inoculated samples. When 10 stacked leaves were irradiated from both sides, a dose of 0.2 kGy was achieved at the center of the stack with a surface dose of 1 kGy, corresponding to a approximately 5-log reduction of E. coli O157:H7 at the center of the stack. Based on these findings, low-energy X-ray irradiation appears to be a promising microbial inactivation strategy for leafy greens and potentially for other types of fresh produce.

  7. Dual Energy X-Ray Absorptiometry Body Composition Reference Values from NHANES

    Science.gov (United States)

    Kelly, Thomas L.; Wilson, Kevin E.; Heymsfield, Steven B.

    2009-01-01

    In 2008 the National Center for Health Statistics released a dual energy x-ray absorptiometry (DXA) whole body dataset from the NHANES population-based sample acquired with modern fan beam scanners in 15 counties across the United States from 1999 through 2004. The NHANES dataset was partitioned by gender and ethnicity and DXA whole body measures of %fat, fat mass/height2, lean mass/height2, appendicular lean mass/height2, %fat trunk/%fat legs ratio, trunk/limb fat mass ratio of fat, bone mineral content (BMC) and bone mineral density (BMD) were analyzed to provide reference values for subjects 8 to 85 years old. DXA reference values for adults were normalized to age; reference values for children included total and sub-total whole body results and were normalized to age, height, or lean mass. We developed an obesity classification scheme by using estabbody mass index (BMI) classification thresholds and prevalences in young adults to generate matching classification thresholds for Fat Mass Index (FMI; fat mass/height2). These reference values should be helpful in the evaluation of a variety of adult and childhood abnormalities involving fat, lean, and bone, for establishing entry criteria into clinical trials, and for other medical, research, and epidemiological uses. PMID:19753111

  8. Dual energy X-Ray absorptiometry body composition reference values from NHANES.

    Directory of Open Access Journals (Sweden)

    Thomas L Kelly

    Full Text Available In 2008 the National Center for Health Statistics released a dual energy x-ray absorptiometry (DXA whole body dataset from the NHANES population-based sample acquired with modern fan beam scanners in 15 counties across the United States from 1999 through 2004. The NHANES dataset was partitioned by gender and ethnicity and DXA whole body measures of %fat, fat mass/height(2, lean mass/height(2, appendicular lean mass/height(2, %fat trunk/%fat legs ratio, trunk/limb fat mass ratio of fat, bone mineral content (BMC and bone mineral density (BMD were analyzed to provide reference values for subjects 8 to 85 years old. DXA reference values for adults were normalized to age; reference values for children included total and sub-total whole body results and were normalized to age, height, or lean mass. We developed an obesity classification scheme by using estabbody mass index (BMI classification thresholds and prevalences in young adults to generate matching classification thresholds for Fat Mass Index (FMI; fat mass/height(2. These reference values should be helpful in the evaluation of a variety of adult and childhood abnormalities involving fat, lean, and bone, for establishing entry criteria into clinical trials, and for other medical, research, and epidemiological uses.

  9. An Experimental Benchmark for Improved Simulation of Absolute Soft X-Ray Emission from Polystyrene Targets Irradiated With the Nike Laser

    National Research Council Canada - National Science Library

    Weaver, J. L; Busquet, M; Colombant, D. G; Mostovych, A. N; Feldman, U; Klapisch, M; Seely, J. F; Brown, C; Holland, G

    2005-01-01

    Absolutely calibrated, time-resolved spectral intensity measurements of soft x-ray emission from laser-irradiated polystyrene targets are compared to radiation-hydrodynamic simulations that include...

  10. Manipulation of Muscle Creatine and Glycogen Changes Dual X-ray Absorptiometry Estimates of Body Composition.

    Science.gov (United States)

    Bone, Julia L; Ross, Megan L; Tomcik, Kristyen A; Jeacocke, Nikki A; Hopkins, Will G; Burke, Louise M

    2017-05-01

    Standardizing a dual x-ray absorptiometry (DXA) protocol is thought to provide a reliable measurement of body composition. We investigated the effects of manipulating muscle glycogen and creatine content independently and additively on DXA estimates of lean mass. Eighteen well-trained male cyclists undertook a parallel group application of creatine loading (n = 9) (20 g·d for 5 d loading; 3 g·d maintenance) or placebo (n = 9) with crossover application of glycogen loading (12 v 6 g·kg BM per day for 48 h) as part of a larger study involving a glycogen-depleting exercise protocol. Body composition, total body water, muscle glycogen and creatine content were assessed via DXA, bioelectrical impedance spectroscopy and standard biopsy techniques. Changes in the mean were assessed using the following effect-size scale: >0.2 small, >0.6, moderate, >1.2 large and compared with the threshold for the smallest worthwhile effect of the treatment. Glycogen loading, both with and without creatine loading, resulted in substantial increases in estimates of lean body mass (mean ± SD; 3.0% ± 0.7% and 2.0% ± 0.9%) and leg lean mass (3.1% ± 1.8% and 2.6% ± 1.0%) respectively. A substantial decrease in leg lean mass was observed after the glycogen depleting condition (-1.4% ± 1.6%). Total body water showed substantial increases after glycogen loading (2.3% ± 2.3%), creatine loading (1.4% ± 1.9%) and the combined treatment (2.3% ± 1.1%). Changes in muscle metabolites and water content alter DXA estimates of lean mass during periods in which minimal change in muscle protein mass is likely. This information needs to be considered in interpreting the results of DXA-derived estimates of body composition in athletes.

  11. X-ray spectroscopy study of electronic structure of laser-irradiated Au nanoparticles in a silica film

    International Nuclear Information System (INIS)

    Jonnard, P.; Bercegol, H.; Lamaignere, L.; Morreeuw, J.-P.; Rullier, J.-L.; Cottancin, E.; Pellarin, M.

    2005-01-01

    The electronic structure of gold nanoparticles embedded in a silica film is studied, both before and after irradiation at 355 nm by a laser. The Au 5d occupied valence states are observed by x-ray emission spectroscopy. They show that before irradiation the gold atoms are in metallic states within the nanoparticles. After irradiation with a fluence of 0.5 J/cm 2 , it is found that gold valence states are close to those of a metal-poor gold silicide; thanks to a comparison of the experimental Au 5d states with the calculated ones for gold silicides using the density-functional theory. The formation of such a compound is driven by the diffusion of the gold atoms into the silica film upon the laser irradiation. At higher fluence, 1 J/cm 2 , we find a higher percentage of metallic gold that could be attributed to annealing in the silica matrix

  12. Production of humoral factors that stimulate spleen colony-forming units in mice irradiated with moderate doses of X rays

    International Nuclear Information System (INIS)

    Grande, T.; Gonzalez, J.; Tejero, C.; Maganto, G.; Bueren, J.A.

    1990-01-01

    The production of humoral factors that stimulate spleen colony-forming units (CFU-S) has been studied in irradiated mice using an in vivo diffusion chamber assay. The experiments show that a significant release of factors that stimulate CFU-S takes place in the first few days after irradiation with moderate doses of 1.5 or 5 Gy. In contrast, the release of significant amounts of these humoral factors was not seen in animals irradiated with either low (0.75 Gy) or high (10 Gy) doses of X rays. The correlation observed between the production of factors that stimulate the CFU-S and the hemopoietic regeneration kinetics of the irradiated mice suggests that these factors represent part of the physiological regulators controlling the proliferation of CFU-S

  13. Extremity x-ray

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003461.htm Extremity x-ray To use the sharing features on this page, ... in the body Risks There is low-level radiation exposure. X-rays are monitored and regulated to provide the ...

  14. Clastogenic effects in human lymphocytes exposed to low and high dose rate X-ray irradiation and vitamin C

    International Nuclear Information System (INIS)

    Konopacka, M; Rogolinski, J.

    2011-01-01

    In the present work we investigated the ability of vitamin C to modulate clastogenic effects induced in cultured human lymphocytes by X-irradiation delivered at either high (1 Gy/min) or low dose rate (0.24 Gy/min). Biological effects of the irradiation were estimated by cytokinesis-block micronucleus assay including the analysis of the frequency of micronuclei (MN) and apoptotic cells as well as calculation of nuclear division index (NDI). The numbers of micronucleated binucleate lymphocytes (MN-CBL) were 24.85 ± 2.67% and 32.56 ± 3.17% in cultures exposed to X-rays (2 Gy) delivered at low and high dose rates, respectively. Addition of vitamin C (1-20 μg/ml) to the medium of cultures irradiated with the low dose rate reduced the frequency of micronucleated lymphocytes with multiple MN in a concentration-dependent manner. Lymphocytes exposed to the high dose rate radiation showed a U-shape response: low concentration of vitamin C significantly reduced the number of MN, whereas high concentration influenced the radiation-induced total number of micronucleated cells insignificantly, although it increased the number of cells with multiple MN. Addition of vitamin C significantly reduced the fraction of apoptotic cells, irrespective of the X-ray dose rate. These results indicate that radiation dose rate is an important exposure factor, not only in terms of biological cell response to irradiation, but also with respect to the modulating effects of antioxidants. (authors)

  15. Body composition by x-ray absorptiometry and bioelectrical impedance in female runners.

    Science.gov (United States)

    Pichard, C; Kyle, U G; Gremion, G; Gerbase, M; Slosman, D O

    1997-11-01

    Body composition interests athletes since athletic performance is influenced by and dependent on the proportion and total amount of fat-free mass (FFM) and fat mass. The use of bioelectrical impedance (BIA) has increased recently since portable instruments make the measurements easy to execute and relatively inexpensive. The purpose of this study was to test the degree of relationship between FFM and fat mass calculated in elite female runners with 12 different BIA formulas reported in the literature and measured by dual-energy x-ray absorptiometry (DXA). The present study shows that body composition by BIA is valid in female runners. Prediction equations used to calculate FFM and fat mass must be appropriate for this population subgroup and validated against other methods, such as DXA and hydrodensitometry. Those formulas that performed well in the controls gave poor results in the female runner and vice versa. The below average fat mass noted in female runners suggests that prediction equations for untrained women with average fat mass are inappropriate. The formula by RJL Systems-2 for women: FFM = 5.091 + 0.6483.height2/resistance + 0.1996.weight gave best predictions of FFM in female runners. Further research is necessary to validate BIA prediction formulas in other athletes.

  16. Hazard and efficiency of X-ray diagnostic investigations

    International Nuclear Information System (INIS)

    1984-01-01

    This symposium deals with the hazards and efficiency of biomedical X-ray examinations. The first articles are devoted to the effects of radiation on the human body. Special attention is paid to low dose irradiation. Later on the efficiency and necessity of X-ray examinations are discussed. Reference is made to the diagnosis of colon- and mammacarcinoma. (Auth.)

  17. The performance of the anthraquinone/p-Si and the pyridine/p-Si rectifying device under X-ray irradiation

    International Nuclear Information System (INIS)

    Şahin, Yılmaz; Aydoğan, Şakir; Ekinci, Duygu; Turut, Abdulmecit

    2016-01-01

    Some X-ray irradiation-induced electrical characteristics of the Au/anthraquinone/p-Si and the Au/pyridine/p-Si junction devices have been investigated. The experimental ideality factors increased for both devices with increasing irradiation dose from 25 Gy to 150 Gy. These values ranged from 1.10 to 1.52 for Au/anthraquinone/p-Si and from 1.46 to 1.77 for Au/pyridine/p-Si, respectively. Furthermore, the barrier height of Au/anthraquinone/p-Si increased with increasing irradiation dose from 0.75 to 0.91 eV, whereas it displayed about a constant value for Au/pyridine/p-Si. In addition, the series resistance of both devices increased with x-ray dose too. The increase in the series resistance with x-ray irradiation has been attributed to the decrease in the active dopant densities. It was seen that the ionization damage is effective on most of the junction characteristics. The leakage current of the Au/anthraquinone/p-Si device decreased with x-ray irradiation since the irradiation induced the formation of electron-hole pairs and hydroquinone structure, and thus some of them are trapped by the interface states. The degradation of the I-V curves of Au/pyridine/p-Si/Al device is attributed to the variation of the surface or interface states distribution for the devices. The reverse and forward bias currents relatively increased after x-ray irradiation because of the decrease in bulk lifetime. In addition, ATR-FTIR spectra of anthraquinone and pyridine films showed that pyridine is more stable than anthraquinone under x-ray irradiation. - Highlights: • Two junction devices based on organic materials were fabricated. • The effect of the x-ray irradiation on devices were examined. • Both devices showed x-irradiation-dependence.

  18. The performance of the anthraquinone/p-Si and the pyridine/p-Si rectifying device under X-ray irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Şahin, Yılmaz [Department of Physics, Faculty of Sciences, University of Atatürk, 25240 Erzurum (Turkey); Aydoğan, Şakir, E-mail: saydogan@atauni.edu.tr [Department of Physics, Faculty of Sciences, University of Atatürk, 25240 Erzurum (Turkey); Ekinci, Duygu [Department of Chemistry, Faculty of Sciences, University of Atatürk, 25240 Erzurum (Turkey); Turut, Abdulmecit [Department of Engineering Physics, Faculty of Sciences, Istanbul Medeniyet University (Turkey)

    2016-11-01

    Some X-ray irradiation-induced electrical characteristics of the Au/anthraquinone/p-Si and the Au/pyridine/p-Si junction devices have been investigated. The experimental ideality factors increased for both devices with increasing irradiation dose from 25 Gy to 150 Gy. These values ranged from 1.10 to 1.52 for Au/anthraquinone/p-Si and from 1.46 to 1.77 for Au/pyridine/p-Si, respectively. Furthermore, the barrier height of Au/anthraquinone/p-Si increased with increasing irradiation dose from 0.75 to 0.91 eV, whereas it displayed about a constant value for Au/pyridine/p-Si. In addition, the series resistance of both devices increased with x-ray dose too. The increase in the series resistance with x-ray irradiation has been attributed to the decrease in the active dopant densities. It was seen that the ionization damage is effective on most of the junction characteristics. The leakage current of the Au/anthraquinone/p-Si device decreased with x-ray irradiation since the irradiation induced the formation of electron-hole pairs and hydroquinone structure, and thus some of them are trapped by the interface states. The degradation of the I-V curves of Au/pyridine/p-Si/Al device is attributed to the variation of the surface or interface states distribution for the devices. The reverse and forward bias currents relatively increased after x-ray irradiation because of the decrease in bulk lifetime. In addition, ATR-FTIR spectra of anthraquinone and pyridine films showed that pyridine is more stable than anthraquinone under x-ray irradiation. - Highlights: • Two junction devices based on organic materials were fabricated. • The effect of the x-ray irradiation on devices were examined. • Both devices showed x-irradiation-dependence.

  19. Body Composition Comparison: Bioelectric Impedance Analysis with Dual-Energy X-Ray Absorptiometry in Adult Athletes

    Science.gov (United States)

    Company, Joe; Ball, Stephen

    2010-01-01

    The primary purpose of this study was to investigate the accuracy of the DF50 (ImpediMed Ltd, Eight Mile Plains, Queensland, Australia) bioelectrical impedance analysis device using dual-energy x-ray absorptiometry as the criterion in two groups: endurance athletes and power athletes. The secondary purpose was to develop accurate body fat…

  20. Repeatability of Volume and Regional Body Composition Measurements of the Lower Limb Using Dual-energy X-ray Absorptiometry

    DEFF Research Database (Denmark)

    Gjorup, Caroline A; Zerahn, Bo; Juul, Sarah

    2017-01-01

    technique allowing multiple measurements of the lower limbs. This study investigated the repeatability of duplicate volume and regional body composition measurements of the lower limb using the GE Lunar Prodigy dual-energy X-ray absorptiometry (DXA) scanner Prodigy (GE Medical Systems, Madison, WI). Twenty...

  1. Foreign body detection in food materials using compton scattered x-rays

    Science.gov (United States)

    McFarlane, Nigel James Bruce

    This thesis investigated the application of X-ray Compton scattering to the problem of foreign body detection in food. The methods used were analytical modelling, simulation and experiment. A criterion was defined for detectability, and a model was developed for predicting the minimum time required for detection. The model was used to predict the smallest detectable cubes of air, glass, plastic and steel. Simulations and experiments were performed on voids and glass in polystyrene phantoms, water, coffee and muesli. Backscatter was used to detect bones in chicken meat. The effects of geometry and multiple scatter on contrast, signal-to-noise, and detection time were simulated. Compton scatter was compared with transmission, and the effect of inhomogeneity was modelled. Spectral shape was investigated as a means of foreign body detection. A signal-to-noise ratio of 7.4 was required for foreign body detection in food. A 0.46 cm cube of glass or a 1.19 cm cube of polystyrene were detectable in a 10 cm cube of water in one second. The minimum time to scan a whole sample varied as the 7th power of the foreign body size, and the 5th power of the sample size. Compton scatter inspection produced higher contrasts than transmission, but required longer measurement times because of the low number of photon counts. Compton scatter inspection of whole samples was very slow compared to production line speeds in the food industry. There was potential for Compton scatter in applications which did not require whole-sample scanning, such as surface inspection. There was also potential in the inspection of inhomogeneous samples. The multiple scatter fraction varied from 25% to 55% for 2 to 10 cm cubes of water, but did not have a large effect on the detection time. The spectral shape gave good contrasts and signal-to-noise ratios in the detection of chicken bones.

  2. Mapping the Ionization State of Laser-Irradiated Ar Gas Jets With Multi-Wavelength Monochromatic X-Ray Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kugland, N L; Doppner, T; Kemp, A; Schaeffer, D; Glenzer, S H; Niemann, C

    2010-04-08

    Two-dimensional monochromatic images of fast-electron stimulated Ar K{alpha} and He-{alpha} x-ray self-emission have recorded a time-integrated map of the extent of Ar{sup {approx}6+} and Ar{sup 16+} ions, respectively, within a high density (10{sup 20} cm{sup -3} atomic density) Ar plasma. This plasma was produced by irradiating a 2 mm wide clustering Ar gas jet with an ultra-high intensity (10{sup 19} W/cm{sup 2}, 200 fs) Ti:Sapphire laser operating at 800 nm. Spherically bent quartz crystals in the 200 (for K{alpha}) and 201 (for He-{alpha}) planes were used as near-normal incidence reflective x-ray optics. We see that a large (830 {micro}m long) region of plasma emits K{alpha} primarily along the laser axis, while the He-{alpha} emission is confined to smaller hot spot (230 {micro}m long) region that likely corresponds to the focal volume of the f/8 laser beam. X-ray spectra from a Bragg spectrometer operating in the von Hamos geometry, which images in one dimension, indicate that the centroids of the K{alpha} and He-{alpha} emission regions are separated by approximately 330 {micro}m along the laser axis.

  3. Mapping the ionization state of laser-irradiated Ar gas jets with multiwavelength monochromatic x-ray imaging.

    Science.gov (United States)

    Kugland, N L; Döppner, T; Kemp, A; Schaeffer, D; Glenzer, S H; Niemann, C

    2010-10-01

    Two-dimensional monochromatic images of fast-electron stimulated Ar Kα and He-α x-ray self-emission have recorded a time-integrated map of the extent of Ar(≈6+) and Ar(16+) ions, respectively, within a high density (10(20) cm(-3) atomic density) Ar plasma. This plasma was produced by irradiating a 2 mm wide clustering Ar gas jet with an ultrahigh intensity (10(19) W/cm(2), 50 TW) Ti:sapphire laser operating at 800 nm. Spherically bent quartz crystals in the 200 (for Kα) and 201 (for He-α) planes were used as near-normal incidence reflective x-ray optics. We see that a large (830 μm long) region of plasma emits Kα primarily along the laser axis, while the He-α emission is confined to smaller hot spot (230 μm long) region that likely corresponds to the focal volume of the f/8 laser beam. X-ray spectra from a Bragg spectrometer operating in the von Hamos geometry indicate that the centroids of the Kα and He-α emission regions are separated by approximately 330 μm along the laser axis.

  4. Dose conversion factors and linear energy transfer for irradiation of thin blood layers with low-energy X rays

    International Nuclear Information System (INIS)

    Verhaegen, F.; Seuntjens, J.

    1994-01-01

    For irradiation of thin samples of biological material with low-energy X rays, conversion of measured air kerma, free in air to average absorbed dose to the sample is necessary. In the present paper, conversion factors from measured air kerma to average absorbed dose in thin blood samples are given for four low-energy X-ray qualities (14-50 kVp). These factors were obtained by Monte Carlo simulation of a practical sample holder. Data for different thicknesses of the blood and backing layer are presented. The conversion factors are found to depend strongly on the thicknesses of the blood layer and backing layer. In radiobiological work, knowledge of linear energy transfer (LET) values for the radiation quality used is often required. Track-averaged LET values for low-energy X rays are presented in this work. It is concluded that the thickness of the sample does not influence the LET value appreciably, indicating that for all radiobiological purposes this value can be regarded as a constant throughout the sample. Furthermore, the large difference between the LET value for a 50 kV spectrum found in this work and the value given in ICRU Report 16 is pointed out. 16 refs., 7 figs., 1 tab

  5. Optimized K (alpha) x-ray flashes from femtosecond-laser-irradiated foils

    Czech Academy of Sciences Publication Activity Database

    Lu, W.; Nicoul, M.; Shymanovich, U.; Tarasevitch, A.; Zhou, P.; Sokolowski-Tinten, K.; von der Linde, D.; Mašek, Martin; Gibbon, P.; Teubner, U.

    2009-01-01

    Roč. 80, č. 2 (2009), 026404/1-026404/10 ISSN 1539-3755 R&D Projects: GA MŠk(CZ) LC528 Institutional research plan: CEZ:AV0Z10100523 Keywords : copper * electron density * high-speed optical techniques * plasma density * plasma production by laser * plasma simulation * plasma x-ray sources * titanium Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.400, year: 2009

  6. Homogenious focusing with a transient soft X-ray laser for irradiation experiments

    Czech Academy of Sciences Publication Activity Database

    Kazamias, S.; Cassou, K.; Guilbaud, O.; Klisnick, A.; Ros, D.; Plé, F.; Jamelot, G.; Rus, Bedřich; Kozlová, Michaela; Stupka, Michal; Mocek, Tomáš; Douillet, D.; Zeitoun, P.; Joyeux, D.; Phalippou, D.

    2006-01-01

    Roč. 263, - (2006), s. 98-104 ISSN 0030-4018 R&D Projects: GA MŠk(CZ) LC528; GA ČR GA202/05/2316 Institutional research plan: CEZ:AV0Z10100523 Keywords : soft X-Ray laser * focusing * laser plasma * UV radiation * beam profile Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.480, year: 2006

  7. Preliminary Study of ZnS:Mn2+ Quantum Dots Response Under UV and X-Ray Irradiation

    Science.gov (United States)

    Saatsakis, G.; Valais, I.; Michail, C.; Fountzoula, C.; Fountos, G.; Koukou, V.; Martini, N.; Kalyvas, N.; Bakas, A.; Sianoudis, I.; Kandarakis, I.; Panayiotakis, G. S.

    2017-11-01

    Quantum Dots are semiconductor nanocrystals, with their optical properties controlled by their size, shape and material composition. The aim of the present study is to examine the scintillation properties of Manganese Doped Zinc Sulfide (ZnS:Mn 2+) Quantum Dot (QDs) nanocrystals under UV and X-ray irradiation. ZnS:Mn 2+ Quantum Dots, with typical diameter of ZnS dots of 13-20nm (also called scintillation QDs, stQDs), were developed and acquired by Mesolight Inc. The initial stQD sample was a solution of 75mg of ZnS:Mn 2+ dissolved in 100μL of Toluene, having a concentration of 75% w/v. Emission characteristics under UV and X-Ray excitation were examined. Two ultraviolet sources were incorporated (315 nm and 365 nm) as well as a medical X-ray tube with tube voltage from 50 to 130 kVp. Parameters such as Energy Quantum Efficiency under UV excitation and Luminescence Efficiency-LE (light energy flux over exposure rate) under X-ray excitation were examined. Luminescence Efficiency (LE) of ZnS:Mn 2+ was higher than that exhibited by previously examined QDs, (ZnCdSeS:ZnS and ZnCuInS:ZnS). The ability of ZnS:Mn 2+ to transform UV photons energy into optical photons energy, tends to increase while the incident UV wavelength decreases. Energy Quantum Efficiency of the sample exhibited a 6% increase when exposed to 315nm UV light compared to 365 nm. The emission spectrum of the stQDs, exhibited a narrow peak (~585nm) in the yellow range.

  8. Synergistic effect of X-ray irradiation and sodium hypochlorite against Salmonella enterica serovar Typhimurium biofilms on quail eggshells.

    Science.gov (United States)

    Jung, Soo-Jin; Park, Shin Young; Ha, Sang-Do

    2018-05-01

    The present study investigated the synergistic bactericidal effects of combined X-ray irradiation (0.5, 1.0, 1.5, and 2.0 kGy) and sodium hypochlorite (NaOCl) (50, 100, 150, 200, and 300 ppm) treatment on the reduction of S. enterica serovar Typhimurium ATCC 14028 biofilms on quail eggshells. Additionally, the color change of the quail eggshells was measured by hunter color "L" (lightness), "a" (red/green), "b" (yellow/blue), and "ΔE" (total color difference). Additionally, the puncture force was tested to evaluate eggshell thickness after the combined treatments. The highest biofilm reduction values were observed as 4.6 log CFU/egg after X-ray (2.0 kGy) and NaOCl (300 ppm) treatment. Moreover, the synergistic reduction in values after combined treatment was evaluated, and the highest biofilm reduction value was 4.3 log CFU/egg by 2.0 kGy X-ray/50 ppm NaOCl (1.47 log higher than the sum of reduction values of the individual treatments). The color of the quail eggshell and puncture force were not significantly changed by combined treatments (p > 0.05 at both cases). Consequently, 2.0 kGy X-ray/50 ppm NaOCl was considered optimal for combination treatment for eliminating S. enterica ser. Typhimurium biofilms on eggshell without any color or thickness changes. Furthermore, combination treatment could be useful for improving microbiological safety in the quail egg industry. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... X-rays are a form of radiation like light or radio waves. X-rays pass through most objects, including the body. Once it is carefully aimed at the part of the body being examined, an x-ray machine produces a small ...

  10. The effect of X-ray irradiation on a red cell component in WB, WRC and LPRC

    International Nuclear Information System (INIS)

    Tayama, Tatsuya; Toyota, Kuroh; Nagahashi, Hisakata; Masuyama, Tetsuya; Haneda, Kenji; Juji, Takeo.

    1990-01-01

    In spite of the use of X-ray irradiation on blood products, few data about its effect on components are reported. We need more informations about a quality of irradiated red cell components. This study shows in vitro changes of irradiated red cell component in WB, WRC and LPRC as the minimum dose of 1,500, 3,000, and 5,000 rads. The fact as follows were observed in response to irradiated doses: 1) increased fragility of red cell membrane, 2) increased amount of plasma K and plasma Hb, and 3) decrease of ATP in WB.2,3-DPG, glucose, pH, Ht and Cl. The numbers of RBC, WBC and Platelet were not affected by irradiation with doses between 1,500 and 5,000 rads. According to these results, the followings are recommended: 1) irradiation with 1,500 rads is a proper method for WB, 2) in order to avoid the risk of increased plasma K, WB should be used within 1 week after irradiation, and WRC and LPRC should be used 24 hours after irradiation. (author)

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the body. X-rays are the oldest and most frequently used form of medical imaging. A bone ... bones. top of page How should I prepare? Most bone x-rays require no special preparation. You ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... image on photographic film or a special detector. Different parts of the body absorb the x-rays ... process is repeated. Two or three images (from different angles) will typically be taken. An x-ray ...

  13. Small-angle neutron and X-ray scattering studies of supraatomic structure of synthetic quartz irradiated by fast neutrons

    International Nuclear Information System (INIS)

    Lebedev, V.M.; Lebedev, V.T.; Orlov, S.P.; Golubkov, V.V.; Pevzner, B.Z.; Tolstikhin, I.N.

    2008-01-01

    Quartz nanostructures have been simulated for the investigation into diffusion of gases in the Earth crust. The nanostructure of synthetic quartz irradiated by fast neutrons with energy E n >0.1 MeV was studied by neutron and X-ray small-angle scattering. The range of neutron fluence is of 10 17 cm -2 up to 2x10 -2 0 cm -2 . In the irradiated samples the different kinds of defects such as point-like, extended linear (dislocations) and globular (size ∼100 nm, amorphous phase nuclei) were observed. The density of highly irradiated quartz (fluence 2x10 20 cm -2 ) is shown to decrease by 0.39 g/cm 2 and reach the magnitude of 2.260 g/cm 2 corresponding to 100% metamict phase. The first results of model structures helium saturation have been received [ru

  14. Effect of X-rays on oogenesis of Telapia mossambica Peters 2. Irradiation of 15 days old larvae

    International Nuclear Information System (INIS)

    Chmilevskij, D.A.

    1982-01-01

    Tilapia larvae of 15 days old after hatching were exposed to x-rays at a dose of 350 R and gonad state in fishes of up to 120 days old was studied. The largest part of sex cells was perished in fishes of 20-30 days old. At the age of 60 days the process of gonad recovery began in consequence of which the number of sex cells in experimetnal fishes tall the end of experiment (fishes of 120 days old after hatching) was the same as in control fishes of the same age. However, unlike the experiment with irradiation of larvae of 6 days old, during irradiation of larvae of 15 days old there was no complete recovery of gonads-oocutes of the irradiated fishes didn't reach the stage of oocyte development under control

  15. X-ray diffraction and microsampling techniques applied to the determination of the O/M ratio of irradiated oxides

    International Nuclear Information System (INIS)

    Trotabas, Maria.

    1980-05-01

    In order to understand the behavior of a mixed irradiated oxide in a fast neutron reactor, it is necessary to know the evolution of one of its principle parameters which is the O/M ratio. A method has been developed based on a double determination of reticular parameters; one after irradiation and the other after an oxidation-reduction heat treatment which brings the O/M ratio down to 2.00. A description is given of the X ray diffraction apparatus that was specially adapted for the examination of irradiated fuels and of the micro-sampling technique that enables spot determinations to be made according to the radius the sample [fr

  16. Effect of 9 MeV x-rays irradiation on development of Xylotrechus rusticus (Coleoptera: Cerambycidae)

    International Nuclear Information System (INIS)

    Wang Yuejin; Xu Liang; Zhan Guoping; Li Baishu; Chang Honglei; Hu Ming; Qin Huaili

    2011-01-01

    Mature larvae and pupae of grey tiger longihorn beetle (Xylotrechus rusticus Pinnaens) were irradiated by 9 MeV X-rays. Pupation rate, emergence rate were measured and the development of pupae, adults and eggs were also observed. The results showed that there were no adults and pupae developed while the mature larvae were irradiated at the dose of 50 Gy and 60 Gy, respectively. The result of probit analysis indicated that the estimated dose for 99.9968% mortality of mature larvae was 72.3 Gy and its 95% confidence interval was 64.4 ∼ 89.1 Gy. 2 ∼ 3 day pupae did not totally dead after irradiated at the dose of 100 Gy, while its sterile dose was less than 80 Gy. (authors)

  17. Radiosensitivity of grapevines. Empirical modelling of the radiosensitivity of some clones to x-ray irradiation. Pt. 1

    International Nuclear Information System (INIS)

    Koeroesi, F.; Jezierska-Szabo, E.

    1999-01-01

    Empirical and formal (Poisson) models were utilized, applying experimental growth data to characterize the radiosensitivity of six grapevine clones to X-ray irradiation. According to the radiosensitivity constants (k), target numbers (n) and volumes, GR 37 doses and energy deposition, the following radiosensitivity order has been found for various vine brands: Chardonnay clone type < Harslevelue K. 9 < Koevidinka K. 8 < Muscat Ottonel clone type < Irsai Oliver K. 11 < Cabernet Sauvignon E. 153. The model can be expanded to describe the radiosensitivity of other plant species and varieties, and also the efficiency of various radioprotecting agents and conditions. (author)

  18. Study of HeLa cells clone survival after X-ray irradiation in the presence of cisplatin

    Science.gov (United States)

    Baulin, A. A.; Sukhikh, E. S.; Vasilyev, S. A.; Sukhikh, L. G.; Sheino, I. N.

    2017-09-01

    Radiation therapy in the presence of heavy elements nuclei (Z > 53) is widely developed these days. The presence of such nuclei in cancer cells results in the local increase of energy release from primary photon beam thus increasing relative biological efficiency. In this paper we present the preliminary results of the cell survival study while irradiating cells by X-Ray photon beam in the presence of cisplatin (Pt, Z = 78). The preliminary results show the decrease of the cell survival in the presence of both radiation and cisplatin.

  19. Apparatus for the examination of a living body by X-rays or γ-rays

    International Nuclear Information System (INIS)

    Hounsfield, G.N.

    1975-01-01

    The apparatus utilizes x-rays or gamma-rays for the representation of the absorption coefficients of a specimen of locations in a level area of the interior of a body with highly different tissues. It consists of the radiation source and a collector with collimator for a narrow bundle of rays. Collector and radiation source on the one hand, and the body on the other hand, are movable relative to each other into various angle- and lateral positions. For this purpose, the collector and the radiation source are attached to a scanning frame relative to a hollow space, with the hollow space serving as a receptable for the body. The scanning frame is controlled in such a way that a lateral scanning motion takes place for each of a succession of rotary steps. From the lateral scanning motion a group of output signals is led away which corresponds to the penetration or absorption of adjacent bundle of rays. Successive groups are led away in accordance with successive rotary steps. A matrix is at hand for the storage of the output signals which reproduces the sectional plane. The output signals are administered to the corresponding matrix elements associated with the scanning path. Drift effects or disturbances which, for instance, can result in ring patterns, are thereby prevented. Furthermore, a store for the storage of impedance factors for intersection areas of the bundles of rays which are associated with the matrix element can be provided. A distributor distributes fault signals, as a function of the valencies of the impedance factors, onto the matrix elements. (HP) [de

  20. Phase-changes in cell cycle of wound tissue irradiated with 5.21 Gy soft X-rays

    International Nuclear Information System (INIS)

    Liu Jianzhong; Zhou Yuanguo; Cheng Tianmin; Zhou Ping; Liu Xia; Li Ping

    2002-01-01

    Objective: To study the phase-changes in cell cycle of wound tissue which was locally irradiated with 5.21 Gy soft X-rays. Methods: Flow cytometry and PI staining were used to analyze cell cycle. Cell proliferation was determined with BrdU labeling. Results: During 3-9 days after irradiation, the percentage of the G 0 /G 1 phase cells in wound of the control side decreased while the percentage of S phase cells increased and reached the highest value on day 9. The percentage of G 2 /M phase cells also increased, and reached its peak on day 15. The percentage of G 0 /G 1 phase cell increased in wound of the irradiation side and was higher than that of the control wound, meanwhile the percentages of S and G 2 /M cells were significantly lower than those of the control wound. In the period of 12-22 days after wounding, the percentage of S phase cells increased and reached its peak value on the 22 th day. When most of cells were in S phase and arrested dramatically. Through the whole healing process, the percentage of G 2 /M in wound of the irradiation side was lower than that of the non-irradiated wound. The BrdU-positive cells were fibroblasts, endothelial cells and smooth muscle cells. Conclusion: These results suggest that G 1 block, S phase arrest, and switch of G 2 /M with suppression of mitotic activity of these cells are induced by local 5.21 Gy soft X-ray irradiation. Therefore, wound healing delay is induced partly by cell cycle arrest

  1. Effects of PTEN transfer on cell cycle progression and expression of P27kipl followed by X-ray irradiation

    International Nuclear Information System (INIS)

    Tian Mei; Wu Congmei; Liu Linlin; Piao Chunji; Li Xiuyi

    2007-01-01

    Objective: To investigate the effect of pEgr-hPTEN stable transfer combined with irradiation on the cell cycle progression and the expression of cell cycle kinase inhibitor P27 kipl protein of SHG-44 human glioma cells. Methods: pEgr-hPTEN vector containing the exogenous wild type PTEN gene was transfected into SHG-44 cells under mediation of lipofectamine in vitro, the positive cell clones were selected and amplified by using G418. Western blotting was used to measure the expression of PTEN protein. Transmission electron microscope was adopted to detect the cell ultrastructural changes and flow cytometry was adopted to analysis the changes of cell cycle progression and the expression of P27 kipl in SHG-44-sPTEN cells followed by different doses of X-ray irradiation. Results: Egr-1 promoter could be induced and activated by irradiation and then enhanced the expression of downstream PTEN gene within 5 Gy. The ultrastructure of SHG-44-sPTEN cells had many degenerative changes and many early apoptotic changes including the chromosome condensate around the nuclear envelope. pEgr-hPTEN stable transfer combined with X-ray irradiation could significantly induce G 1 arrest. The expression of P27 kipl proteins increased in SHG-44-sPTEN stable transfected cells. Conclusion: PTEN stable transfer combined with irradiation can significantly induce G 1 arrest. The molecular basis may be correlated with the enhanced expression of PTEN induced by irradiation and increased expression of cell cycle kinase inhibitor P27 kipl . (authors)

  2. Detecting meaningful body composition changes in athletes using dual-energy x-ray absorptiometry

    International Nuclear Information System (INIS)

    Colyer, Steffi L; Roberts, Simon P; Thompson, Dylan; Stokes, Keith A; Bilzon, James L J; Salo, Aki I T; Robinson, Jonathan B

    2016-01-01

    Dual-energy x-ray absorptiometry (DXA) imaging is considered to provide a valid and reliable estimation of body composition when stringent scanning protocols are adopted. However, applied practitioners are not always able to achieve this level of control and the subsequent impact on measurement precision is not always taken into account when evaluating longitudinal body composition changes. The primary aim of this study was to establish the reliability of DXA in an applied elite sport setting to investigate whether real body composition changes can be detected. Additionally, the performance implications of these changes during the training year were investigated. Forty-eight well-trained athletes (from four diverse sports) underwent two DXA scans using a ‘real-world’ approach (with limited pre-scan controls), typically within 48 h, to quantify typical error of measurement (TEM). Twenty-five athletes underwent further scans, before and after specific training and competition blocks. ‘True’ body composition changes were evaluated using 2  ×  TEM thresholds. Twelve bob skeleton athletes also performed countermovement jump and leg press tests at each time point. Many ‘true’ body composition changes were detected and coincided with the primary training emphases (e.g. lean mass gains during hypertrophy-based training). Clear relationships (r  ±  90% CI) were observed between performance changes (countermovement jump and leg press) and changes in lean mass (0.53  ±  0.26 and 0.35  ±  0.28, respectively) and fat mass (−0.44  ±  0.27 and  −0.37  ±  0.28, respectively). DXA was able to detect real body composition changes without the use of stringent scanning controls. Associations between changes in body composition and performance demonstrated the potential influence of these changes on strength and power indices. (paper)

  3. Medium from X-rayed cultures induces DNA strand-breaks in non-irradiated HeLa cells

    Energy Technology Data Exchange (ETDEWEB)

    Ikushima, T.; Okuyama, K.; Tanizaki, Y. [Kyoto Univ., Kyoto (Japan)

    2002-07-01

    There is growing evidence to indicate that several types of responses are induced by ionizing radiation in non-irradiated cells. Such bystander effects include the killing of non-irradiated cells, the induction of sister chromatid exchanges and chromosomal aberrations, and the induction of gene mutations and chromosomal instability and enhanced cell growth. In the present study, we assessed whether the medium from irradiated cultures can induce DNA strand-breaks in non-irradiated cells, using single-cell gel electrophoresis assay (comet assay). HeLa cells in culture were irradiated with 0.5 to 8 Gy of 140 kVp X-rays and one hour later, the medium was taken from the irradiated culture, passed through a filter and transferred to the parallel culture of non-irradiated HeLa cells as non-target cells. After incubation for 30 min, the comet assay was performed under alkaline and neutral conditions. Such treatments resulted in a dose-dependent increase in tail moment under either alkaline or neutral condition, indicating the induction of DNA single- or double-strand breaks, respectively. It was also shown that the clonogenic survival was reduced in the cells cultured in the medium from irradiated cultures. Such a change was not detected at all when medium alone was irradiated. These results provided disputed evidence that irradiated cells released certain genotoxic factor(s) into the culture medium that can induce DNA strand breaks leading to cell death. Our results suggest that physical contact between irradiated and non-irradiated cells may not be necessary for the bystander effects observed in this study. It appears that bystander responses may be mediated by multiple mechanisms.

  4. Medium from X-rayed cultures induces DNA strand-breaks in non-irradiated HeLa cells

    International Nuclear Information System (INIS)

    Ikushima, T.; Okuyama, K.; Tanizaki, Y.

    2002-01-01

    There is growing evidence to indicate that several types of responses are induced by ionizing radiation in non-irradiated cells. Such bystander effects include the killing of non-irradiated cells, the induction of sister chromatid exchanges and chromosomal aberrations, and the induction of gene mutations and chromosomal instability and enhanced cell growth. In the present study, we assessed whether the medium from irradiated cultures can induce DNA strand-breaks in non-irradiated cells, using single-cell gel electrophoresis assay (comet assay). HeLa cells in culture were irradiated with 0.5 to 8 Gy of 140 kVp X-rays and one hour later, the medium was taken from the irradiated culture, passed through a filter and transferred to the parallel culture of non-irradiated HeLa cells as non-target cells. After incubation for 30 min, the comet assay was performed under alkaline and neutral conditions. Such treatments resulted in a dose-dependent increase in tail moment under either alkaline or neutral condition, indicating the induction of DNA single- or double-strand breaks, respectively. It was also shown that the clonogenic survival was reduced in the cells cultured in the medium from irradiated cultures. Such a change was not detected at all when medium alone was irradiated. These results provided disputed evidence that irradiated cells released certain genotoxic factor(s) into the culture medium that can induce DNA strand breaks leading to cell death. Our results suggest that physical contact between irradiated and non-irradiated cells may not be necessary for the bystander effects observed in this study. It appears that bystander responses may be mediated by multiple mechanisms

  5. Comparison of diagnostic value of multidetector computed tomography and X-ray in the detection of body packing

    Energy Technology Data Exchange (ETDEWEB)

    Bulakci, Mesut, E-mail: mesutbulakci@yahoo.com [Department of Radiology, Haseki Training and Research Hospital, 34096 Aksaray, Istanbul (Turkey); Kalelioglu, Tuba, E-mail: tubakarsakarya@hotmail.com [Department of Radiology, Haseki Training and Research Hospital, 34096 Aksaray, Istanbul (Turkey); Bulakci, Betul Bozkurt, E-mail: dr.betulbozkurt@gmail.com [Department of Family Medicine, Istanbul University, Istanbul Faculty of Medicine, 34390 Capa, Istanbul (Turkey); Kiris, Adem, E-mail: ademkiris@hotmail.com [Department of Radiology, Haseki Training and Research Hospital, 34096 Aksaray, Istanbul (Turkey)

    2013-08-15

    Objective: Radiologists and other clinicians are facing an increasing number of illegal drug-related medical conditions. We aimed to draw attention to this growing global problem and to highlight some of the important points related to diagnosis and follow-up of body packing. We compare the diagnostic performance of unenhanced multidetector CT (MDCT) and abdomen X-ray for the detection of drug-filled packets. Materials and methods: Sixty-seven suspects, who underwent both CT and X-ray examinations, have been included in the study. All MDCT and X-ray images were independently and retrospectively reviewed by two observers with different degrees of experience in abdomen imaging. Fifty-two of them were identified as body packers finally. Interobserver agreement, sensitivity, specificity, positive and negative predictive value were calculated. Results: Two types of packets with different characteristics were identified in all body packers. Type 1 packets (solid-state drug) were found in 41 patients and type 2 packets (liquid cocaine) in 11 patients. All statistical analyses concern the detection of any packets. That is, the whole evaluation has been performed per patient. Sensitivity/specificity values of type 1 and type 2 packets for MDCT were 100–98%/100–100% and 100–100%/100–100%, respectively. Besides, sensitivity/specificity values of type 1 and type 2 packets for X-ray were 93–90%/100–91% and 64–45%/73–71%, respectively. In addition, interobserver agreements for detection of any packets were excellent (κ = 0.96) and good (κ = 0.75) for interpretation of MDCT and X-ray, respectively. Conclusion: Unenhanced MDCT is a fast, accurate and easily used diagnostic tool with high sensitivity and specificity for the exact diagnosis of body packing.

  6. Effect of localized intraoperative x-rays irradiation followed by intermittent external exposure on certain histochemical parameters related to pancreatic function

    International Nuclear Information System (INIS)

    Abdel-Azeem, M.G.

    2005-01-01

    The present study was carried out to evaluate the pancreatic enzyme activities in rabbits, whose splenic part of pancreas was exposed to local intraoperative radiation therapy (IORT) at level of 30 Gy X-rays followed by fractionated external radiation therapy (ERT) at a total dose of 40 Gy (2 Gy day after day) starting from the 15th day following the local intraoperative irradiation. The control pancreas was that received only external X-rays radiation without local irradiation. The exocrine pancreatic functions were assessed by determination of insulin hormone and enzyme activity of lipase as well as alkaline and acid phosphatases. After local X-rays irradiation on days 2 and 10 and after external X-rays irradiation on days 23 , 33 , 43 and 53, technovit-8100 plastic embedding (Kulzer and Heraeus) was used to prepare the cold blocks. The quantitative morphometric method was used to evaluate the histochemical pancreatic activity of the irradiated and control pancreas of each rabbit. Most of the studied parameters recorded non-significant changes as a result of the applied different levels of X-rays irradiation, which would give the chance to use this type of irradiation in pancreatic radiotherapy without any hazards to the pancreas

  7. Characterization of neutron-irradiated HT-UPS steel by high-energy X-ray diffraction microscopy

    International Nuclear Information System (INIS)

    Zhang, Xuan; Park, Jun-Sang; Almer, Jonathan; Li, Meimei

    2016-01-01

    This paper presents the first measurement of neutron-irradiated microstructure using far-field high-energy X-ray diffraction microscopy (FF-HEDM) in a high-temperature ultrafine-precipitate-strengthened (HT-UPS) austenitic stainless steel. Grain center of mass, grain size distribution, crystallographic orientation (texture), diffraction spot broadening and lattice constant distributions of individual grains were obtained for samples in three different conditions: non-irradiated, neutron-irradiated (3dpa/500 °C), and irradiated + annealed (3dpa/500 °C + 600 °C/1 h). It was found that irradiation caused significant increase in grain-level diffraction spot broadening, modified the texture, reduced the grain-averaged lattice constant, but had nearly no effect on the average grain size and grain size distribution, as well as the grain size-dependent lattice constant variations. Post-irradiation annealing largely reversed the irradiation effects on texture and average lattice constant, but inadequately restored the microstrain.

  8. Characterization of neutron-irradiated HT-UPS steel by high-energy X-ray diffraction microscopy

    Science.gov (United States)

    Zhang, Xuan; Park, Jun-Sang; Almer, Jonathan; Li, Meimei

    2016-04-01

    This paper presents the first measurement of neutron-irradiated microstructure using far-field high-energy X-ray diffraction microscopy (FF-HEDM) in a high-temperature ultrafine-precipitate-strengthened (HT-UPS) austenitic stainless steel. Grain center of mass, grain size distribution, crystallographic orientation (texture), diffraction spot broadening and lattice constant distributions of individual grains were obtained for samples in three different conditions: non-irradiated, neutron-irradiated (3dpa/500 °C), and irradiated + annealed (3dpa/500 °C + 600 °C/1 h). It was found that irradiation caused significant increase in grain-level diffraction spot broadening, modified the texture, reduced the grain-averaged lattice constant, but had nearly no effect on the average grain size and grain size distribution, as well as the grain size-dependent lattice constant variations. Post-irradiation annealing largely reversed the irradiation effects on texture and average lattice constant, but inadequately restored the microstrain.

  9. Characteristics of specifications of transportable inverter-type X-ray equipment

    International Nuclear Information System (INIS)

    Yamamoto, Keiichi; Miyazaki, Shigeru

    2003-01-01

    Our X-ray systems study group measured and examined the characteristics of four transportable inverter-type X-ray equipments. X-ray tube voltage and X-ray tube current were measured with the X-ray tube voltage and the X-ray tube current measurement terminals provided with the equipment. X-ray tube voltage, irradiation time, and dose were measured with a non-invasive X-ray tube voltage-measuring device, and X-ray output was measured by fluorescence meter. The items investigated were the reproducibility and linearity of X-ray output, error of pre-set X-ray tube voltage and X-ray tube current, and X-ray tube voltage ripple percentage. The waveforms of X-ray tube voltage, the X-ray tube current, and fluorescence intensity draw were analyzed using the oscilloscope gram and a personal computer. All of the equipment had a preset error of X-ray tube voltage and X-ray tube current that met Japanese Industrial Standards (JIS) standards. The X-ray tube voltage ripple percentage of each equipment conformed to the tendency to decrease when X-ray tube voltage increased. Although the X-ray output reproducibility of system A exceeded the JIS standard, the other systems were within the JIS standard. Equipment A required 40 ms for X-ray tube current to reach the target value, and there was some X-ray output loss because of a trough in X-ray tube current. Owing to the influence of the ripple in X-ray tube current, the strength of the fluorescence waveform rippled in equipments B and C. Waveform analysis could not be done by aliasing of the recording device in equipment D. The maximum X-ray tube current of transportable inverter-type X-ray equipment is as low as 10-20 mA, and the irradiation time of chest X-ray photography exceeds 0.1 sec. However, improvement of the radiophotographic technique is required for patients who cannot move their bodies or halt respiration. It is necessary to make the irradiation time of the equipments shorter for remote medical treatment. (author)

  10. A track length estimator method for dose calculations in low-energy X-ray irradiations. Implementation, properties and performance

    Energy Technology Data Exchange (ETDEWEB)

    Baldacci, F.; Delaire, F.; Letang, J.M.; Sarrut, D.; Smekens, F.; Freud, N. [Lyon-1 Univ. - CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Centre Leon Berard (France); Mittone, A.; Coan, P. [LMU Munich (Germany). Dept. of Physics; LMU Munich (Germany). Faculty of Medicine; Bravin, A.; Ferrero, C. [European Synchrotron Radiation Facility, Grenoble (France); Gasilov, S. [LMU Munich (Germany). Dept. of Physics

    2015-05-01

    The track length estimator (TLE) method, an 'on-the-fly' fluence tally in Monte Carlo (MC) simulations, recently implemented in GATE 6.2, is known as a powerful tool to accelerate dose calculations in the domain of low-energy X-ray irradiations using the kerma approximation. Overall efficiency gains of the TLE with respect to analogous MC were reported in the literature for regions of interest in various applications (photon beam radiation therapy, X-ray imaging). The behaviour of the TLE method in terms of statistical properties, dose deposition patterns, and computational efficiency compared to analogous MC simulations was investigated. The statistical properties of the dose deposition were first assessed. Derivations of the variance reduction factor of TLE versus analogous MC were carried out, starting from the expression of the dose estimate variance in the TLE and analogous MC schemes. Two test cases were chosen to benchmark the TLE performance in comparison with analogous MC: (i) a small animal irradiation under stereotactic synchrotron radiation therapy conditions and (ii) the irradiation of a human pelvis during a cone beam computed tomography acquisition. Dose distribution patterns and efficiency gain maps were analysed. The efficiency gain exhibits strong variations within a given irradiation case, depending on the geometrical (voxel size, ballistics) and physical (material and beam properties) parameters on the voxel scale. Typical values lie between 10 and 103, with lower levels in dense regions (bone) outside the irradiated channels (scattered dose only), and higher levels in soft tissues directly exposed to the beams.

  11. Degradation of poly(methylmethacrylate) by deep ultraviolet, x-ray, electron beam, and proton beam irradiations

    International Nuclear Information System (INIS)

    Choi, J.O.; Moore, J.A.; Corelli, J.C.; Silverman, J.P.; Bakhru, H.

    1988-01-01

    The chemical changes in poly(methylmethacrylate) (PMMA) caused by irradiation with deep ultraviolet (UV), x-ray, electron, and proton beams were studied by gel permeation chromatography, Fourier-transform infrared, and UV spectroscopy. The quantitative analysis of spectroscopic changes (Beer's law) demonstrated a 1:1 correspondence between the disappearance of ester groups and the generation of double bonds in the polymer chain by all types of radiation. The ratio of main chain scission to changes in the number of ester groups and unsaturated bonds was compared to determine the characteristics of degradation of PMMA by the different types of radiation. This ratio for deep UV data was very close to the quantum yield of main chain scission of PMMA as reported in the literature. High-energy radiation was /similar to/0 x more efficient than deep UV in causing main chain scission with removal of fewer ester groups. Protons induced more main chain scission than electrons. X-ray irradiation was the most efficient at causing main chain scission of the four different types of radiation

  12. X-ray irradiation-induced structural changes on Single Wall Carbon Nanotubes

    Science.gov (United States)

    Bardi, N.; Jurewicz, I.; King, A. K.; Alkhorayef, M. A.; Bradley, D.; Dalton, A. B.

    2017-11-01

    Dosimetry devices based on Carbon Nanotubes are a promising new technology. In particular using devices based on single wall Carbon Nanotubes may offer a tissue equivalent response with the possibility for device miniaturisation, high scale manufacturing and low cost. An important precursor to device fabrication requires a quantitative study of the effects of X-ray radiation on the physical and chemical properties of the individual nanotubes. In this study, we concentrate on the effects of relatively low doses, 20 cGy and 45 cGy , respectively. We use a range of characterization techniques including scanning electron microscopy, Raman spectroscopy and X-ray photoelectron spectroscopy to quantify the effects of the radiation dose on inherent properties of the nanotubes. Specifically we find that the radiation exposure results in a reduction in the sp2 nature of the nanotube bond structure. Moreover, our analysis indicates that the exposure results in nanotubes that have an increased defect density which ultimately effects the electrical properties of the nanotubes.

  13. Degradation of DNA in Haemophilus influenza cells after X-ray irradiation

    International Nuclear Information System (INIS)

    Randolph, M.L.

    1976-01-01

    Models of the kinetics of degradation of DNA in bacterial cells following exposure to x-rays are developed and tested using data obtained with various strains of Haemophilus influenzae cells. Different mathematical models allow for different initial distributions of DNA lengths, depending on cell phase and assumed replication model, and for unilateral or bilateral degradation from initiation points, which are taken as single-strand breaks. In order to explain the observed magnitude and time course of degradation an interruption-of-degradation probability, which may be interpreted as the result of an x-ray inducible inhibitor, is introduced. Interruption of degradation is interpreted as an early and essential, but not necessarily sufficient, step for repair of DNA. Empirical best fits to the kinetic data were obtained by iterative calculation methods based on varying the rate parameters. Depending somewhat on the strain and cell phase, the data seem best described by assuming bilateral degradation, perhaps at different rates, whose total for log phase wild-type cells is roughly 5 x 10 3 nucleotides/min and an interruption rate of about 0.03/min. For stationary phase the total degradation rate is greater and the probability of degradation unchanged. Differences in the kinetics between strains are discussed briefly. (author)

  14. MeV single-ion beam irradiation of mammalian cells using the Surrey vertical nanobeam, compared with broad proton beam and X-ray irradiations

    Energy Technology Data Exchange (ETDEWEB)

    Prakrajang, K. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Faculty of Science, Maejo University, Chiang Mai 50290 (Thailand); Jeynes, J.C.G.; Merchant, M.J.; Kirkby, K.; Kirkby, N. [Surrey Ion Beam Center, Faculty of Engineering and Physical Science, University of Surrey, Guildford Surrey, GU2 7XH (United Kingdom); Thopan, P. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Yu, L.D., E-mail: yuld@fnrf.science.cmu.ac.th [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand)

    2013-07-15

    Highlights: •Recently completed nanobeam at the Surrey Ion Beam Centre was used. •3.8-MeV single and broad proton beams irradiated Chinese hamster cells. •Cell survival curves were measured and compared with 300-kV X-ray irradiation. •Single ion irradiation had a lower survival part at ultra-low dose. •It implies hypersensitivity, bystander effect and cell cycle phase of cell death. -- Abstract: As a part of a systematic study on mechanisms involved in physical cancer therapies, this work investigated response of mammalian cells to ultra-low-dose ion beam irradiation. The ion beam irradiation was performed using the recently completed nanobeam facility at the Surrey Ion Beam Centre. A scanning focused vertical ion nano-beam was applied to irradiate Chinese hamster V79 cells. The V79 cells were irradiated in two different beam modes, namely, focused single ion beam and defocused scanning broad ion beam of 3.8-MeV protons. The single ion beam was capable of irradiating a single cell with a precisely controlled number of the ions to extremely low doses. After irradiation and cell incubation, the number of surviving colonies as a function of the number of the irradiating ions was measured for the cell survival fraction curve. A lower survival for the single ion beam irradiation than that of the broad beam case implied the hypersensitivity and bystander effect. The ion-beam-induced cell survival curves were compared with that from 300-kV X-ray irradiation. Theoretical studies indicated that the cell death in single ion irradiation mainly occurred in the cell cycle phases of cell division and intervals between the cell division and the DNA replication. The success in the experiment demonstrated the Surrey vertical nanobeam successfully completed.

  15. Demonstration of a neonlike argon soft-x-ray laser with a picosecond-laser-irradiated gas puff target.

    Science.gov (United States)

    Fiedorowicz, H; Bartnik, A; Dunn, J; Smith, R F; Hunter, J; Nilsen, J; Osterheld, A L; Shlyaptsev, V N

    2001-09-15

    We demonstrate a neonlike argon-ion x-ray laser, using a short-pulse laser-irradiated gas puff target. The gas puff target was formed by pulsed injection of gas from a high-pressure solenoid valve through a nozzle in the form of a narrow slit and irradiated with a combination of long, 600-ps and short, 6-ps high-power laser pulses with a total of 10 J of energy in a traveling-wave excitation scheme. Lasing was observed on the 3p (1)S(0)?3s (1)P(1) transition at 46.9 nm and the 3d (1)P(1)?3p (1)P(1) transition at 45.1 nm. A gain of 11 cm(-1) was measured on these transitions for targets up to 0.9 cm long.

  16. Gene mutations, chromosome aberrations and survival after X-ray irradiation of cultured Chinese hamster cells at cysteamine protection

    International Nuclear Information System (INIS)

    Elisova, I.V.; Feoktistova, I.P.

    1983-01-01

    The culture of Chinese hamster cells (clone 431) has been used to study cysteamine action on mutagenous effect of X-rays, determined by the induction of resistance of gene mutations to 6-thioguanine and chromosomal abberations, as well as on the reproductive form of death of irradiated cells. Dose--- effect curves are obtained under conditions of irradiation with and without protector. The factor of dose alteration is 2.0 for chromosomal aberrations and cell survival, and 2.8 for gene mutations. It is sUpposed that cysteamine affects the general mechanisms, which take part in the realis zation of injuries that bring about gene mutations, chromosomal aberrations and cell lethality

  17. Acute response of pig skin to irradiation with 12C-ions or 200 kV X-rays

    International Nuclear Information System (INIS)

    Zacharias, T.; Doerr, W.; Enghardt, W.; Roethig, H.; Herrmann, T.; Kumpf, R.

    1997-01-01

    The acute response of pig skin to treatment with high energy carbon ions (plateau region) at the Gesellschaft fuer Schwerionenforschung (GSI, Darmstadt, Germany) was compared with changes after 200 kV X-irradiation. Carbon doses isoeffective to the X-ray doses were computed with a recently estbalished model for calculation of the biological effect of heavy ions. Clinical changes and physiological symptoms (blood flow, erythema, trans-epidermal water loss, skin hydration) were scored. The parameters analyzed were maximum and mean values of each symptom during days 24 to 70 after irradiation, and the quantal endpoints for the establishment of dose-effect curves were the median values of these. With exception of the maximum change in the red blood cell concentration (p 12 C-ions (plateau region) and may at least for epidermis be applied to treatment planning. (orig.)

  18. Synchrotron X-ray diffraction investigations on strains in the oxide layer of an irradiated Zircaloy fuel cladding

    Science.gov (United States)

    Chollet, Mélanie; Valance, Stéphane; Abolhassani, Sousan; Stein, Gene; Grolimund, Daniel; Martin, Matthias; Bertsch, Johannes

    2017-05-01

    For the first time the microstructure of the oxide layer of a Zircaloy-2 cladding after 9 cycles of irradiation in a boiling water reactor has been analyzed with synchrotron micro-X-ray diffraction. Crystallographic strains of the monoclinic and to some extent of the tetragonal ZrO2 are depicted through the thick oxide layer. Thin layers of sub-oxide at the oxide-metal interface as found for autoclave-tested samples and described in the literature, have not been observed in this material maybe resulting from irradiation damage. Shifts of selected diffraction peaks of the monoclinic oxide show that the uniform strain produced during oxidation is orientated in the lattice and displays variations along the oxide layer. Diffraction peaks and their shifts from families of diffracting planes could be translated into a virtual tensor. This virtual tensor exhibits changes through the oxide layer passing by tensile or compressive components.

  19. Many-body effects on the x-ray spectra of metals

    International Nuclear Information System (INIS)

    Satpathy, S.S.

    1982-01-01

    The effects of band structure, of a solid surface, of temperature, and of disorder on the many-electron x-ray spectra of metals are evaluated in a change-of-mean-field approximation using a one-dimensional nearest-neighbor tight-binding model of a metal. The x-ray spectral shapes are determined by both the band structure and the final-state interactions. The effect of the band being non-free-electron-like is not felt at the x-ray threshold, but away from it such effects are noticeable. When the core hole is created at the surface, the spectra at the edge exhibit a Nozieres-de Dominicis-type singularity with the appropriate surface phase-shifts. At energies away from the edge, the one-particle effects are prominent with the x-ray emission and absorption spectra closely reflecting the local one-electron density of states. The recoil spectrum of a Fermi sea at a non-zero temperature has less asymmetry than the zero-temperature case. It was found that at ordinary temperatures the reduction of the asymmetry due to the thermal distribution of one-electron states is not very significant. Finally, using a one-dimensional Anderson model, the effect of lattice disorder on the x-ray absorption spectra is studied for the first time. There are two effects: (1) the strong infrared divergence peak is gradually quenched as disorder is increased, and (2) the threshold is broadened because the threshold energies for absorption at different sites in the crystal depend on the varying local lattice environment. It is proposed that the x-ray spectra may be useful as a tool for studying the degree of electron localization in disordered many-electron systems

  20. Study on the apoptosis and Bcl-2/Bax expression of human hepatoma SMMC-7721 cells after exposure to heavy-ion and X-ray irradiations

    International Nuclear Information System (INIS)

    Ye Lanping; Xu Hua; An Lizhe; Jin Xiaodong; Li Qiang

    2007-01-01

    This study is aimed at observing the apoptosis and Bcl-2/Bax gene expression of mammalian cells following heavy-ion and X-ray irradiations. Exponentially growing human hepatoma SMMC-7721 cells cultured in vitro were irradiated with a 12 C ion beam of 50 MeV/u (corresponding to a LET value of 44.56 keV/S38m) from Heavy Ion Research Facility in Lanzhou (HIRFL) at doses varying from 0 to 3 Gy. The X-ray irradiation (8 MV) was performed in the therapy unit of the General Hospital of the Lanzhou Military Area. Survival fractions of irradiated cells at various doses were measured by means of MTT assay. Apoptotic cells after irradiation were analyzed with fluorescence microscope and flow cytometer (FCM). Immuno-histological assay were applied to detect the expression of Bcl-2/Bax genes in the irradiated cells. The survival fraction of SMMC-7721 cells decreased gradually (vs. control p<0.05) with increasing the dose of the carbon ion beam more obviously than X-ray irradiation, and the carbon ion irradiation efficiently induced cell apoptosis and significantly promoted the expression of Bax gene while Bcl-2 gene expression was restrained. High-LET heavy ion beam would induce cell apoptosis effectively than low-LET X-ray, and the apoptosis rate is correlated with the transcription of Bcl-2/Bax and the ratio of Bcl-2/Bax in human hepatoma SMMC-7721 cells after irradiation to heavy ion beam. (author)

  1. Characterization of the effects of x-ray irradiation on the hierarchical structure and mechanical properties of human cortical bone

    Energy Technology Data Exchange (ETDEWEB)

    Barth, Holly; Zimmermann, Elizabeth; Schaible, Eric; Tang, Simon; Alliston, Tamara; Ritchie, Robert

    2011-08-19

    Bone comprises a complex structure of primarily collagen, hydroxyapatite and water, where each hierarchical structural level contributes to its strength, ductility and toughness. These properties, however, are degraded by irradiation, arising from medical therapy or bone-allograft sterilization. We provide here a mechanistic framework for how irradiation affects the nature and properties of human cortical bone over a range of characteristic (nano to macro) length-scales, following x-­ray exposures up to 630 kGy. Macroscopically, bone strength, ductility and fracture resistance are seen to be progressively degraded with increasing irradiation levels. At the micron-­scale, fracture properties, evaluated using in-situ scanning electron microscopy and synchrotron x-ray computed micro-tomography, provide mechanistic information on how cracks interact with the bone-matrix structure. At sub-micron scales, strength properties are evaluated with in-situ tensile tests in the synchrotron using small-/wide-angle x-ray scattering/diffraction, where strains are simultaneously measured in the macroscopic tissue, collagen fibrils and mineral. Compared to healthy bone, results show that the fibrillar strain is decreased by ~40% following 70 kGy exposures, consistent with significant stiffening and degradation of the collagen. We attribute the irradiation-­induced deterioration in mechanical properties to mechanisms at multiple length-scales, including changes in crack paths at micron-­scales, loss of plasticity from suppressed fibrillar sliding at sub-­micron scales, and the loss and damage of collagen at the nano-­scales, the latter being assessed using Raman and Fourier-Transform-Infrared spectroscopy and a fluorometric assay.

  2. On the effect of x-ray irradiation on the deformation and fracture behavior of human cortical bone

    Energy Technology Data Exchange (ETDEWEB)

    Barth, Holly D.; Launey, Maximilien E.; McDowell, Alastair A.; Ager III, Joel W.; Ritchie, Robert O.

    2010-01-10

    In situ mechanical testing coupled with imaging using high-energy synchrotron x-ray diffraction or tomography imaging is gaining in popularity as a technique to investigate micrometer and even sub-micrometer deformation and fracture mechanisms in mineralized tissues, such as bone and teeth. However, the role of the irradiation in affecting the nature and properties of the tissue is not always taken into account. Accordingly, we examine here the effect of x-ray synchrotron-source irradiation on the mechanistic aspects of deformation and fracture in human cortical bone. Specifically, the strength, ductility and fracture resistance (both work-of-fracture and resistance-curve fracture toughness) of human femoral bone in the transverse (breaking) orientation were evaluated following exposures to 0.05, 70, 210 and 630 kGy irradiation. Our results show that the radiation typically used in tomography imaging can have a major and deleterious impact on the strength, post-yield behavior and fracture toughness of cortical bone, with the severity of the effect progressively increasing with higher doses of radiation. Plasticity was essentially suppressed after as little as 70 kGy of radiation; the fracture toughness was decreased by a factor of five after 210 kGy of radiation. Mechanistically, the irradiation was found to alter the salient toughening mechanisms, manifest by the progressive elimination of the bone's capacity for plastic deformation which restricts the intrinsic toughening from the formation 'plastic zones' around crack-like defects. Deep-ultraviolet Raman spectroscopy indicated that this behavior could be related to degradation in the collagen integrity.

  3. Stability and linearity of luminescence imaging of water during irradiation of proton-beams and X-ray photons lower energy than the Cerenkov light threshold

    Science.gov (United States)

    Yamamoto, Seiichi; Koyama, Shuji; Yabe, Takuya; Komori, Masataka; Tada, Junki; Ito, Shiori; Toshito, Toshiyuki; Hirata, Yuho; Watanabe, Kenichi

    2018-03-01

    Luminescence of water during irradiations of proton-beams or X-ray photons lower energy than the Cerenkov-light threshold is promising for range estimation or the distribution measurements of beams. However it is not yet obvious whether the intensities and distributions are stable with the water conditions such as temperature or addition of solvable materials. It remains also unclear whether the luminescence of water linearly increases with the irradiated proton or X-ray energies. Consequently we measured the luminescence of water during irradiations of proton-beam or X-ray photons lower energy than the Cerenkov-light threshold with different water conditions and energies to evaluate the stability and linearity of luminescence of water. We placed a water phantom set with a proton therapy or X-ray system, luminescence images of water with different conditions and energies were measured with a high-sensitivity cooled charge coupled device (CCD) camera during proton or X-ray irradiations to the water phantom. In the stability measurements, imaging was made for different temperatures of water and addition of inorganic and organic materials to water. In the linearity measurements for the proton, we irradiated with four different energies below Cerenkov light threshold. In the linearity measurements for the X-ray, we irradiated X-ray with different supplied voltages. We evaluated the depth profiles for the luminescence images and evaluated the light intensities and distributions. The results showed that the luminescence of water was quite stable with the water conditions. There were no significant changes of intensities and distributions with the different temperatures. Results from the linearity experiments showed that the luminescence of water linearly increased with their energies. We confirmed that luminescence of water is stable with conditions of water. We also confirmed that the luminescence of water linearly increased with their energies.

  4. [Body composition by dual-energy x-ray absorptiometry in women with fibromyalgia].

    Science.gov (United States)

    Lobo, Márcia Maria Marques Teles; Paiva, Eduardo dos Santos; Andretta, Aline; Schieferdecker, Maria Eliana Madalozzo

    2014-01-01

    To assess body composition in women with fibromyalgia (FM) comparing to the reference value for healthy women. Cross-sectional observational analytical study, with 52 women selected with Fibromyalgia, according American College of Rheumatology (ACR, 1990) criteria. The patients were selected in Hospital de Clínicas da Universidade Federal do Paraná (HC-UFPR) and divided into two groups, 28 patients with a BMI (Body Mass Index) equal or higher (≥) than 25kg/m2 and 24 patients with BMI less or equal (≤) 24.99 kg/m2, subjected to physical examination for the count of tender points (TP) and completing the fibromyalgia impact questionnaire (FIQ). The assessment of body composition was performed by the Dual-Energy X-Ray Absorptiometry (DXA). The values of the fat mass percentage (MG %) found in the two groups were compared to the average percentage of MG by age and sex, described by Heward (2004). The mean age of the study groups was 47.8 ± 8.6 years, the FIQ score was 70.5 ± 18.6 and TP 16.2 ± 2.0. The mean BMI was 26.4 ± 4.1 kg/m2, and the amount of MG was 25.2 ± 7.8 kg and 39.5 ± 6.8%, and lean mass (LM) was 37 2 ± 3.7 kg and 60.4 ± 7.3%. In the group with BMI ≤ 25 kg/m2, the MG % was 33.8% (21.5 -42.4) and in the group with BMI ≥ 25 kg/m2 of the MG was 44.4% (37.6 -56.2). Both groups women with FM eutrophic as the overweight and obese group, presented higher reference MG% levels comparing with the standard levels for healthy women. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.

  5. Combination of BMP-2-releasing gelatin/β-TCP sponges with autologous bone marrow for bone regeneration of X-ray-irradiated rabbit ulnar defects.

    Science.gov (United States)

    Yamamoto, Masaya; Hokugo, Akishige; Takahashi, Yoshitake; Nakano, Takayoshi; Hiraoka, Masahiro; Tabata, Yasuhiko

    2015-07-01

    The objective of this study is to evaluate the feasibility of gelatin sponges incorporating β-tricalcium phosphate (β-TCP) granules (gelatin/β-TCP sponges) to enhance bone regeneration at a segmental ulnar defect of rabbits with X-ray irradiation. After X-ray irradiation of the ulnar bone, segmental critical-sized defects of 20-mm length were created, and bone morphogenetic protein-2 (BMP-2)-releasing gelatin/β-TCP sponges with or without autologous bone marrow were applied to the defects to evaluate bone regeneration. Both gelatin/β-TCP sponges containing autologous bone marrow and BMP-2-releasing sponges enhanced bone regeneration at the ulna defect to a significantly greater extent than the empty sponges (control). However, in the X-ray-irradiated bone, the bone regeneration either by autologous bone marrow or BMP-2 was inhibited. When combined with autologous bone marrow, the BMP-2 exhibited significantly high osteoinductivity, irrespective of the X-ray irradiation. The bone mineral content at the ulna defect was similar to that of the intact bone. It is concluded that the combination of bone marrow with the BMP-2-releasing gelatin/β-TCP sponge is a promising technique to induce bone regeneration at segmental bone defects after X-ray irradiation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Stability of semiconducting transition metal dichalcogenides irradiated by soft X-rays and low energy electrons

    Science.gov (United States)

    Walker, Roger C.; Bhimanapati, Ganesh R.; Shi, Tan; Zhang, Kehao; Eichfeld, Sarah M.; Jovanovic, Igor; Robinson, Joshua A.

    2017-04-01

    Semiconducting two-dimensional materials (2DMs) such as molybdenum disulfide and tungsten diselenide have attracted significant attention due to their unique electronic properties. Understanding their nanoscale radiation tolerance is needed for developing radiation-hardened nanoelectronics. Here, we report that the XPS environment of soft X-ray (E = 1.486 keV) exposure in a vacuum combined with a low energy electron flood gun leads to charge accumulation in the 2D layers over time, with little impact on layer chemistry. Additionally, the charging that induced the 2DM/substrate heterostructure depends more on the growth technique, the size of as-grown domains, and the surface coverage of the 2DM than the conductivity of the substrate. Charging is minimized for the combination of a continuous 2DM film and strong coupling between the 2DM and the substrate.

  7. X-ray masks

    International Nuclear Information System (INIS)

    Greenwood, J.C.; Satchell, D.W.

    1984-01-01

    In semiconductor manufacture, where X-ray irradiation is used, a thin silicon membrane can be used as an X-ray mask. This membrane has areas on which are patterns to define the regions to be irradiated. These regions are of antireflection material. With the thin, in the order of 3 microns, membranes used, fragility is a problem. Hence a number of ribs of silicon are formed integral with the membrane, and which are relatively thick, 5 to 10 microns. The ribs may be formed by localised deeper boron deposition followed by a selective etch. (author)

  8. The plexus chorioideus and its ultrastructural changes following prenatal X-ray irradiation

    International Nuclear Information System (INIS)

    Heinzmann, U.

    1982-01-01

    Pregnant mice were exposed to 0.95 or 1.9 Gy whole body radiation on the 12th day of gestation. The offspring and control animals were narcotised, mounted, and the plexus choroid was examined. The first and most important precondition was to prepare a perfect image of the epithelial plexus. The second step was to compare the SEM results with the obtained TEM results, and these were again compared with the TEM results of other authors. The third step was to use exposed and control animals synchronously for SEM and TEM examination. This permitted a comparison of the morphological modifications of the choroid plexus. The morphological findings in control mice correspond largely to those of other species. As a result of the irradiation, the kinocilia of the plexus cells are shortened or disappear partly or completely. They are not only able to perform the normal ciliar movement but also react to noxae. Further experiments will also show the consequence of oedematous dilatation of the interstice, the dilated intercellular spaces in the epithelial plexus, the change of the apical microvilli and possible interrelationships with the radiation-induced hydrocephalus. (orig.) [de

  9. Study of the gamma emission from the 31-year isomer of 178Hf induced by X-ray irradiation

    International Nuclear Information System (INIS)

    Collins, C.B.; Davanloo, F.; Iosif, M.C.

    1999-01-01

    A sample containing 6.3x10 14 nuclei of the 16 + isomer of 178 Hf having a half-life of 31 years and excitation energy of 2.446 MeV was irradiated with x-ray pulses derived from a device operated at 15mA to produce Bremsstrahlung radiation with an end point energy set to be 90 keV. Gamma-spectra of the isomeric target were taken with a Ge-detector. Intensity of the 325.5 keV (6 + →4 + transition in the ground state band of 178 Hf was found to increase by about 2%. Such an accelerated decay of the 178 Hf isomer is consistent with an integrated cross section of 3x10 -23 cm 2 ·keV if the resonant absorption takes place within the energy ranges corresponding to the maxima of the x-ray flux, either near 20 keV, or at the K emission lines of W

  10. Thermoluminescence Response of Copper-Doped Potassium Borate Glass Subjected to 6 Megavolt X-Ray Irradiation

    Science.gov (United States)

    Hossain, I.; Shekaili, N. K.; Wagiran, H.

    2015-03-01

    This study addresses the characteristics of Cu-doped and undoped potassium borate glass for use as ionizing radiation dosimeters by investigating and comparing the thermoluminescence responses, linearity, sensitivity and dose response s of the two types of glasses. A number of samples based on xK 2 CO 3 + (100 - x)H 3 BO 3 , where 10 ≤ x ≤ 30 mol.%, have been prepared using a melt quenching technique. The amorphous phases were identified using X-ray diffraction (XRD). The undoped potassium borate samples 20K 2 CO 3 + 80H 3 BO 3 (mol.%) and Cu-doped (0.5 mol.%) samples were placed in a solid phantom apparatus and irradiated with in X-ray tube under 6 MV accelerating voltage with doses ranging from 0.5 to 4.0 Gy. This beam was produced by the Primus MLC 3339 linear accelerator (LINAC) available at Hospital Sultan Ismail, Johor Bahru, Malaysia. The results clearly show the superiority of Cu-doped glass in terms of response and sensitivity to producing luminescence over undoped potassium borate glass. The sensitivity of Cu-doped glass is 6.75 times greater than that of undoped glass.

  11. ESR study of X-ray irradiated rare earth (Ln) ion-doped glaserite and Ln ion-doped langbeinite

    International Nuclear Information System (INIS)

    Ohta, Masatoshi; Kuroi, Shigeaki; Sakaguchi, Masakazu

    1992-01-01

    X-ray irradiation-induced paramagnetic radicals in rare earth (Ln) ion-doped glaserite and Ln ion-doped langbeinite were studied by means of ESR technique, aiming at developing the highly sensitive sensor for an ESR dosimetry. The samples were prepared by two kinds of procedures as follows. In one process, the glaserite (K 3 Na(SO 4 ) 2 ) matrix or the langbeinite (K 2 Mg 2 (SO 4 ) 3 ) matrix were synthesized by heating the mixture of K 2 SO 4 and Na 2 SO 4 or the mixture of K 2 SO 4 and MgSO 4 at 1023 K for 1 hour in He flow. The matrices obtained were mixed well with a fixed amount of Ln 2 (SO 4 ) 3 (Ln=La, Eu, Gd, Lu) powder and heated at 1023 K for 1 hour in He flow. In the other process, the homogeneous mixture of a fixed amount of K 2 SO 4 , Na 2 SO 4 and Ln 2 (SO 4 ) 3 powders or a fixed amount of K 2 SO 4 , MgSO 4 and Ln 2 (S0 4 ) 3 powders was heated at 1023 K for 2 hours in He flow. The glaserite was more favorable matrix than the langbeinite, because of the ease of the diffusion rare earth ion into the matrix due to the phase transition of the matrix. A remarkable difference was observed in ESR signal intensity for Ln ion-doped glaserite prepared by a different process, because of the formation of the solid solution between Na 2 SO 4 and Ln 2 (SO 4 ) 3 prior to the formation of the glaserite in the latter process. The paramagnetic radicals (SO 3 - ) was easily produced by the irradiation of X-ray in the sample doped with the stable trivalent rare earth ion. The Gd ion-doped (0.1 mol%) glaserite faded hardly and was available for the highly sensitive sensor to measure the irradiation dose of X-ray. (author)

  12. X-ray crystallography

    Science.gov (United States)

    2001-01-01

    X-rays diffracted from a well-ordered protein crystal create sharp patterns of scattered light on film. A computer can use these patterns to generate a model of a protein molecule. To analyze the selected crystal, an X-ray crystallographer shines X-rays through the crystal. Unlike a single dental X-ray, which produces a shadow image of a tooth, these X-rays have to be taken many times from different angles to produce a pattern from the scattered light, a map of the intensity of the X-rays after they diffract through the crystal. The X-rays bounce off the electron clouds that form the outer structure of each atom. A flawed crystal will yield a blurry pattern; a well-ordered protein crystal yields a series of sharp diffraction patterns. From these patterns, researchers build an electron density map. With powerful computers and a lot of calculations, scientists can use the electron density patterns to determine the structure of the protein and make a computer-generated model of the structure. The models let researchers improve their understanding of how the protein functions. They also allow scientists to look for receptor sites and active areas that control a protein's function and role in the progress of diseases. From there, pharmaceutical researchers can design molecules that fit the active site, much like a key and lock, so that the protein is locked without affecting the rest of the body. This is called structure-based drug design.

  13. Inhibitory effects of prior low-dose X-ray irradiation on carbon tetrachloride-induced hepatopathy in acatalasemic mice

    International Nuclear Information System (INIS)

    Yamaoka, Kiyonori; Kataoka, Takahiro; Taguchi, Takehito; Wang, Da-Hong; Mori, Shuji; Hanamoto, Katsumi; Kira, Shohei; Nomura, Takaharu

    2004-01-01

    The catalase activities in blood and organs of the acatalasemic (C3H/AnLCs b Cs b ) mouse of C3H strain are lower than those of the normal (C3H/AnLCs a Cs a ) mouse. We examined the effects of prior low-dose (0.5 Gy) X-ray irradiation, which reduced the oxidative damage under carbon tetrachloride-induced hepatopathy in the acatalasemic or normal mice. The acatalasemic mice showed a significantly lower catalase activity and a significantly higher glutathione peroxidase activity compared with those in the normal mice. Moreover, low-dose irradiation increased the catalase activity in the acatalasemic mouse liver to a level similar to that of the normal mouse liver. Pathological examinations and analyses of blood glutamic oxaloacetic and glutamic pyruvic transaminase activity and lipid peroxide levels showed that carbon tetrachloride induced hepatopathy was inhibited by low-dose irradiation. These findings may indicate that the free radical reaction induced by the lack of catalase and the administration of carbon tetrachloride is more properly neutralized by high glutathione peroxidase activity and low-dose irradiation in the acatalasemic mouse liver. (author)

  14. Possibility of restoration of skull voult bone ragenarative ability in rabbits after its suppression by local X-ray irradiation

    International Nuclear Information System (INIS)

    Kantorova, V.I.

    1986-01-01

    The skull cap of rabbits was irradiated locally by X-rays with 1100, 1200 and 1500 R doses, then parts of left and right frontal bones of 1 cm 2 in size were removed. A nonirradiated grownd bone of some animals irradiated with 1200, 150 P doses, was implanted into the region of defect. It is established that under the effect of the implanted refined bone tissue in the region of the defect of the irradiated voult bone destructive processes suppressed by X radiation are stimulated. Yield-up of morphogenetically active agents (extracellular matrix) stimulating the growth of vessels and migration of competent hemopoietic and osteogenous cells-predecessors from the screened organism in the region of the defected bone and agents causing their osteogenous differentiation is the result of it, i.e. under the effect of the implant the interaction between vessels distructed by irradiation; between the bone and the homopoietic tissue, as well as an inductive mechanism of regeneration are recovered

  15. Effect of long-time X-ray irradiation on Cr and Hg in a polypropylene disk certified reference material observed during measurements by X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Ohata, Masaki; Kidokoro, Toshihiro

    2015-01-01

    The effect of long-time X-ray irradiation on Cr and Hg in a polypropylene disk certified reference material (PP disk CRM, NMIJ CRM 8136-a) during measurements by X-ray fluorescence (XRF) spectrometry was examined in the present study. The XRF intensities of Cr (K α ), Hg (L α ) and Pb (L α ), obtained by an energy-dispersive (ED)-XRF spectrometer, showed the different intensity trends and the obtained XRF intensity ratios of Cr/Pb and Hg/Pb revealed decreasing and constant ratios, respectively, for long-time X-ray irradiation of up to 430 h. A similar decreasing trend of the Cr/Pb intensity ratio was also observed by wavelength-dispersive (WD)-XRF measurements for 120 h. Moreover, Cr, Hg and Pb in the PP disks obtained after long-time measurements by the WD-XRF spectrometer were measured by an ED-XRF spectrometer, and the loss of Cr was confirmed. From these results, Cr in the PP disk CRM, whose chemical form was an organometallic compound, was considered to be possibly lost during the XRF analysis for long-time or frequent measurements. (author)

  16. Velocity-resolved [Ne III] from X-ray irradiated Sz 102 microjets

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Chun-Fan; Shang, Hsien [Institute of Astronomy and Astrophysics, Academia Sinica (ASIAA), P.O. Box 23-141, Taipei 10641, Taiwan (China); Walter, Frederick M. [Department of Physics and Astronomy, Stony Brook University, Stony Brook, NY 11794-3800 (United States); Herczeg, Gregory J. [The Kavli Institute for Astronomy and Astrophysics, Peking University, Beijing 100871 (China)

    2014-05-10

    Neon emission lines are good indicators of high-excitation regions close to a young stellar system because of their high ionization potentials and large critical densities. We have discovered [Ne III] λ3869 emission from the microjets of Sz 102, a low-mass young star in Lupus III. Spectroastrometric analyses of two-dimensional [Ne III] spectra obtained from archival high-dispersion (R ≈ 33, 000) Very Large Telescope/UVES data suggest that the emission consists of two velocity components spatially separated by ∼0.''3, or a projected distance of ∼60 AU. The stronger redshifted component is centered at ∼ + 21 km s{sup –1} with a line width of ∼140 km s{sup –1}, and the weaker blueshifted component at ∼ – 90 km s{sup –1} with a line width of ∼190 km s{sup –1}. The two components trace velocity centroids of the known microjets and show large line widths that extend across the systemic velocity, suggesting their potential origins in wide-angle winds that may eventually collimate into jets. Optical line ratios indicate that the microjets are hot (T ≲ 1.6 × 10{sup 4} K) and ionized (n{sub e} ≳ 5.7 × 10{sup 4} cm{sup –3}). The blueshifted component has ∼13% higher temperature and ∼46% higher electron density than the redshifted counterpart, forming a system of an asymmetric pair of jets. The detection of the [Ne III] λ3869 line with the distinct velocity profile suggests that the emission originates in flows that may have been strongly ionized by deeply embedded hard X-ray sources, most likely generated by magnetic processes. The discovery of [Ne III] λ3869 emission along with other optical forbidden lines from Sz 102 supports the picture of wide-angle winds surrounding magnetic loops in the close vicinity of the young star. Future high-sensitivity X-ray imaging and high angular-resolution optical spectroscopy may help confirm the picture proposed.

  17. Analysis of fine structure of X-ray spectra from laser-irradiated gold dot

    International Nuclear Information System (INIS)

    Yang Guohong; Zhang Jiyan; Zhang Baohan; Zhou Yuqing; Li Jun

    2000-01-01

    The X-ray emission spectra from highly stripped plasma of gold has been observed by focusing a Nd-glass frequency tripled laser beam onto the surface of the gold dot at the XINGGUANG II laser facilities. The spectra of gold ions in the range of 0.0003 nm-0.0004 nm was recorded using the plate PET (2d = 0.8742 nm) crystal spectrometer. The code of average energy of relativistic sub-arrays was built on the basis of the code MCDF (Multi-Configuration-Dirac-Fock). Using the spin-orbit-split-arrays (SOSA) formalism, mean wavelengths and full widths at half height of isolated peaks of sub-arrays of lower charged gold ions, isoelectronic with Cu, Zn, Ga and Ge, was calculated. Twenty-six lines are interpreted, they pertain mainly to transitions of 3d-nf (n = 5,6,7) of gold ions from Ni-like to As-like. These results of experiment and calculation have important application in plasma diagnostics and examination of high Z elemental atomic structure calculation

  18. Application of the autoblood treated by preliminary extracorporeal X-ray irradiation in the therapy of bronchial asthma patients

    International Nuclear Information System (INIS)

    Goguev, N.T.

    1985-01-01

    A therapeutic method including extracorporeal x-ray irradiation of the autoblood of patients with bronchial asthma complicated by cortisone dependence and polyvalent drug intolerance, has been elaborated and clinically tested. The use of this method brings about good short-term results in 90% of cases and good long-term results in 40% of cases (14-38 months). It provides an opportunity to give up corticosteroids in more than 60% of patients and to decrease the hormone dose in the rest of cortisone-dependent patients with bronchial asthma. The above therapeutic method can be used as an independent type of treatment, especially in the presence of polyvalent drug allergy and as an element of multiple modality therapy of bronchial asthma patients. The method was used under in-patient conditions only. No side effects were marked in the course of the clinical trial. To carry out this type of therapy, patients should be thoroughly screened

  19. Effect of a low-dose x-ray irradiation on the development and differentiation of the cerebral cortex, (15)

    International Nuclear Information System (INIS)

    Hayashi, Yasushi; Hoshino, Kiyoshi; Hayasaka, Shizuka; Kameyama, Yoshiro

    1981-01-01

    Mice of 17 day's gestation received x-rays of 10 R, 25 R, or 100 R, and those of 13 or 15 day's gestation received 10 R in a single exposure. These irradiated fetuses were examined for the weight of the brain, thickness of the cerebral cortex, density of the cortical cells and branching of the pyramidal cells in the fifth layer of the cortex 12 weeks after birth. Decrease in the thickness of the cortex was observed in the mice which received 100 R at 17 day's gestation. A decrease in the branching index of the pyramidal cells was found in the mice which received 100 R. Although a decreasing tendency of the branching index was also recognized in those which received 10 R at 13 days of gestation, showing no statistically significant difference. (Ueda, J.)

  20. Static characteristic and transient behavior of a N+PNN+ transistor irradiated with flash-X ray

    International Nuclear Information System (INIS)

    Sudre, Christophe; Dachs, Charles; Pelancho, Frederic; Palau, J.-N.; Gasiot, Jean

    1996-01-01

    This work concerns a parasitic N + PNN + transistor appearing in a power MOSFET. 2D Medici simulations point out a close correlation between the static characteristic and the transient values of both the current and the reverse bias of the transistor irradiated by a flash-X ray. The static characteristic points out a steady-state where the transistor behaves as a resistor. If the dose rate is sufficient, it can bring the transistor to the same steady-state. In both cases, this steady-state is reached after the same physical process: conduction of the emitter-base junction, shift of the electric field towards the NN + junction and highly avalanching conditions in the device. (author)

  1. The effect of caffeine on p53-dependent radioresponses in undifferentiated mouse embryonal carcinoma cells after X-ray and UV-irradiations

    International Nuclear Information System (INIS)

    Taga, Masataka; Shiraishi, Kazunori; Shimura, Tsutomu; Uematsu, Norio; Kato, Tomohisa; Niwa, Ohtsura; Nishimune, Yoshitake; Aizawa, Shinichi; Oshimura, Mitsuo

    2000-01-01

    The effect of caffeine was studied on the radioresponses of undifferentiated mouse embryonal carcinoma cells (EC cells) with or without the functional p53. The radioresponses studied included radiosensitivity, the activation of p53, apoptosis with characteristic DNA ladder formation and cell cycle progression. An undifferentiated mouse EC cell line, ECA2, and a newly established p53-deficient EC cell line, p53δ, were used in the present study. The status of the p53 gene did not significantly affect the colony survivals of undifferentiated EC cells to X-rays and UV. Although a post-irradiation treatment with caffeine sensitized both lines to X-rays marginally, the sensitization was prominent for UV regardless of the p53 status of the cells. The activation of a p53 responsible lacZ reporter construct was observed in stably transfected ECA2 cells after X-ray and UV irradiations. Caffeine suppressed the X-ray induced activation of the lacZ reporter, while it drastically enhanced the activation after UV irradiation. X-rays and UV readily triggered the apoptosis of ECA2 cells with the characteristic DNA ladder. Although UV-induced DNA ladder formation was enhanced by caffeine, that induced by X-rays was unaffected. Therefore, the effects of caffeine on the p53-dependent radioresponses were found to be agent specific: suppression for the X-ray induced and augmentation for the UV induced. In contrast to p53-proficient ECA2 cells, smear-like DNA degradation was observed for irradiated p53δ cells, suggesting the presence of a mode of cell death without DNA ladder formation. UV induction of the smear-like DNA degradation was enhanced in the presence of caffeine. Regardless of the state of the p53 gene, G1/S arrest was not observed in X-ray and UV irradiated EC cells. X-rays induced G2/M arrest in both lines, which was abrogated by caffeine, while G2/M arrest after UV was unaffected by a caffeine treatment. These results indicate that the radioresponses of undifferentiated

  2. Developmental abnormalities of the vitreous in mouse fetuses caused by simultaneous irradiation of x-rays and ultrasound

    International Nuclear Information System (INIS)

    Shirai, Shoichiro; Yuguchi, Shuji; Majima, Akio

    1980-01-01

    Eye abnormalities in mouse fetuses caused by irradiation of X-rays alone, or simultaneous irradiation of X-rays and ultrasound on day 7 of gestation were histologically studied on day 18 of gestation. Developmental abnormalities of the vitreous were examined in the present experiment, and the following results were obtained. 1. Developmental abnormalities of the vitreous were observed in 23 fetused, and unilateral cases were 15 of 23 fetuses. In 31 eyes with these abnormalities, much more abundant mesenchymal tissue of components of primary vitreous was found in the retrolental vitreous cavity than in the normal eyes. 2. The above 31 eyes were also accompanied by a variety of ocular abnormalities such as microphthalmia, faulty closure of the fetal fissure, aplasia and hypoplasia of the optic nerve, goniodysgenesis, and corneolenticular adhesion. Complications observed to be associated with developmental abnormalities of the vitreous were lens abnormalities, retinal traction and fold, fibrovascular anastomosis between mesenchymal tissues of the chamber angle and vitrious cavity, retinal rosette, and anomalies of the optic nerve head. 3. The histological findings of 17 eyes corresponded to anterior persistent hyperplastic primary vitreous (PHPV) encountered clinically, those of 3 eyes to posterior PHPV, those of 6 eyes to mixed type of both anterior and posterior types, and those of 5 eyes to PHPV of the optic nerve head. In 3 bilateral cases, the type was different for either eye. 4. From these results, it was considered that the pathogenesis of PHPV of Reese and congenital retinal fold of Mann consists of the maldevelopment of the components of the primary vitreous, and that the type of defect is depends on the portion involved and the degree depends on the time at which the maldevelopment occurs. (author)

  3. Developmental abnormalities of the optic nerve head in mouse fetuses caused by simultaneous irradiation of x-rays and ultrasound

    International Nuclear Information System (INIS)

    Shirai, Shoichiro; Yuguchi, Shuji; Majima, Akio.

    1981-01-01

    Eye abnormalities in mouse fetuses caused by irradiation of X-rays alone, or simultaneous irradiation of X-rays and ultrasound on day 7 of gestation were histologically studied on day 18 of gestation. Developmental abnormalities of the optic nerve head were examined in the present experiment, and the following results were obtained: 1. Developmental abnormalities of the optic nerve head associated with developmental abnormalities of the vitreous were detected in 4 fetuses (5 eyes). In all cases, excessive mesenchymal tissue of components of the primary vitreous was found from the optic nerve head to the vitreous cavity. It was impossible to distinguish between the neuroectodermal tissue of Bergmeister's papilla and the mesodermal tissue of components of the primary vitreous. 2. In 3 fetuses (4 eyes), the fetal fissure involving the optic nerve head was open. At the peripapillary region, the inner layer of the optic cup was everted and hyperplastic. The inner neuroblastic layer of the everted portion contacted the outer coat of the eyeball, directly. In these cases, the optic nerve entrance was very wide. 3. The relation between the congenital optic nerve head anomalies encountered clinically and those observed experimentally in the mouse fetuses was discussed. It was considered that the pathogenesis of congenital optic nerve head anomalies consists of the malformation of the primitive epithelial papilla, the faulty closure of the proximal end of the fetal fissure, the anomalies of Bergmeister's papilla, the anomalies of the hyaloid system, or the abnormal differentiation and growth of the neuroectodermal cells of the optic cup. (author)

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... body. Once it is carefully aimed at the part of the body being examined, an x-ray machine produces a small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different parts of the body absorb the x-rays in ...

  5. MeV single-ion beam irradiation of mammalian cells using the Surrey vertical nanobeam, compared with broad proton beam and X-ray irradiations

    Science.gov (United States)

    Prakrajang, K.; Jeynes, J. C. G.; Merchant, M. J.; Kirkby, K.; Kirkby, N.; Thopan, P.; Yu, L. D.

    2013-07-01

    As a part of a systematic study on mechanisms involved in physical cancer therapies, this work investigated response of mammalian cells to ultra-low-dose ion beam irradiation. The ion beam irradiation was performed using the recently completed nanobeam facility at the Surrey Ion Beam Centre. A scanning focused vertical ion nano-beam was applied to irradiate Chinese hamster V79 cells. The V79 cells were irradiated in two different beam modes, namely, focused single ion beam and defocused scanning broad ion beam of 3.8-MeV protons. The single ion beam was capable of irradiating a single cell with a precisely controlled number of the ions to extremely low doses. After irradiation and cell incubation, the number of surviving colonies as a function of the number of the irradiating ions was measured for the cell survival fraction curve. A lower survival for the single ion beam irradiation than that of the broad beam case implied the hypersensitivity and bystander effect. The ion-beam-induced cell survival curves were compared with that from 300-kV X-ray irradiation. Theoretical studies indicated that the cell death in single ion irradiation mainly occurred in the cell cycle phases of cell division and intervals between the cell division and the DNA replication. The success in the experiment demonstrated the Surrey vertical nanobeam successfully completed.

  6. The study of dual energy X-ray absorptiometry on body composition components in obesity

    International Nuclear Information System (INIS)

    Huang Zhongkui; Chen Wei; Long Liling; Li Xiaoyang

    2009-01-01

    Objective: To study the correlation of the bone mineral density (BMD) and the body composition components of body mass index (BMI), FAT and LEAN in Chinese obesity. Methods: There were 150 cases in obesity group diagnosed by BMI, including 75 males [ median age 46 years, mean weight (89.64 ± 8.33) kg] and 75 females [median age 45 years, mean weight (77.23 ± 6.85) kg]. There were 150 persons with normal BMI in the control group, including 75 males [(median age 47 years, mean weight (62.34 ± 5.72) kg] and 75 females [ median age 45 years, mean weight (50.16 ± 5.06) kg]. The body height and weight of 300 persons in two groups were measured respectively and ,simultaneously calculated the BMI. These data and the body composition parameters measured by the dual energy X-ray absorptiometry (DEXA) in these two groups were compared and analyzed. The data obtained used two-sample t-test analysis, bi-variable correlation used Pearson linear correlation analysis and multi-variable correlation used multiple linear regression analysis. Results: FAT of arms, legs trunk and total body of male cases in obesity group was (2.90 ± 0.57), (7.48 ± 1.46), (15.67 ± 3.05), (30.92 ± 5.94) kg respectively, FAT% was (30.9 ± 5.1)%, (30.6 ± 5.8)%, (37.3 ± 4.7)%, (35.1 ± 4.4)% respectively, it was significantly higher than that in control group [FAT was (1.12 ± 0.64), (3.27 ± 1.22), (6.71 ± 3.29), (11.61 ± 5.16) kg respectively, FAT% was (15.4 ± 4.8)%, (16.5 ± 5.0)%, (21.8 ± 5.8)%, (18.6 ± 5.3)% respectively], P 2 respectively, it was significantly higher than that in control group [ LEAN was (22.89 ± 1.68), (48.89 ± 3.72) kg respectively, BMD was (0.89 ± 0.07), (1.15 ± 0.06) g/cm 2 respectively], P 2 respectively, and there were no statistical significance compared with those in control group [LEAN was (5.99 ± 0.72), (16.83 ± 1.67) kg respectively, BMD was (0.90 ± 0.08), (1.29 ± 0.09) g/cm 2 respectively]. FAT of arms, legs, trunk and total body of females in

  7. Preventive effect of ganoderma lucidum (Reishi) on the suppression of hematopoietic system by X-ray irradiation

    International Nuclear Information System (INIS)

    Itoh, Hiroko; Nakata, Fukuyoshi; Sasaki, Hiroyuki; Ito, Hitoshi

    2013-01-01

    Reishi has been used for a roborant or the elixir of life from ancient times. In the present study, the preventive effects of Reishi on hematopoietic suppression from X-ray irradiation in mice were investigated. 5.0 Gy-irradiated mice induced the decrease of red blood cell, platelet, white blood cell, granulocytes, the index of spleen and thymus, and the number of spleen cells. Oral administration of Reishi tended to decrease these damage on hematopoiesis, and reticuloendothelial system. Reishi enhanced the degree of spleen cells-mediated sheep red blood cells (SRBC) hemolysis (quantitative hemolysis of SRBC). Reishi augmented the level of erythroid burst-forming cell (BFU-E), and accelerated the recovery of the number of BFU-E in X-irradiated mice, although Reishi did not influence red blood cell counts and colony-forming unit-erythropoetin dependent (CFU-E) number. A significant elevation in the CFU-GM (granulocytes-macrophages) level was observed. Histological examinations revealed that Reishi accerelated the hematopoietic recovery and decrease on damage of spleen and thymus. (author)

  8. Investigation of irradiated X-ray crystal stability for ITER diagnostics system

    Energy Technology Data Exchange (ETDEWEB)

    Kosenkov, V.M. (V.I. Lenin Research Institute of Atomic Reactors, 433510 Dimitrovgrad (Russian Federation)); Neverov, V.A. (V.I. Lenin Research Institute of Atomic Reactors, 433510 Dimitrovgrad (Russian Federation)); Revyakin, Y.L. (V.I. Lenin Research Institute of Atomic Reactors, 433510 Dimitrovgrad (Russian Federation)); Orlinsky, D.V. (Russian Scientific Center, Kurchatov Institute, 123182 Moscow (Russian Federation))

    1994-09-01

    The possible neutron irradiation effect on gamma-spectrometer operation intended for diagnostics of ITER plasma was analysed. Nine types of crystals Ge (111), Si (220), SiO[sub 2] (1010), SiO[sub 2] (1120), SiO[sub 2] (0003), pyrolytic graphite (0002), pentaeritrit (002), potassium biphtalate (001), rubidium biphtalate (001) used in monochromator were irradiated in the BOR-60 reactor up to fluence 2.2x10[sup 19] n/cm[sup -2] at temperature 65 C. Change of reflecting ability, interplane distance, width and form for diffraction reflections were studied. Ge, Si and graphite crystals were not changed after irradiation. In SiO[sub 2] the damage depends on reflection plane. The organic crystals were delaninated and cracked. ((orig.))

  9. Investigation of the internal electric field distribution under in situ x-ray irradiation and under low temperature conditions by the means of the Pockels effect

    International Nuclear Information System (INIS)

    Prekas, G; Sellin, P J; Veeramani, P; Davies, A W; Lohstroh, A; Oezsan, M E; Veale, M C

    2010-01-01

    The internal electric field distribution in cadmium zinc telluride (CdZnTe) x-ray and γ-ray detectors strongly affects their performance in terms of charge transport and charge collection properties. In CdZnTe detectors the electric field distribution is sensitively dependent on not only the nature of the metal contacts but also on the working conditions of the devices such as the temperature and the rate of external irradiation. Here we present direct measurements of the electric field profiles in CdZnTe detectors obtained using the Pockels electo-optic effect whilst under in situ x-ray irradiation. These data are also compared with alpha particle induced current pulses obtained by the transient current technique, and we discuss the influence of both low temperature and x-ray irradiation on the electric field evolution. Results from these studies reveal strong distortion of the electric field consistent with the build-up of space charge at temperatures below 250 K, even in the absence of external irradiation. Also, in the presence of x-ray irradiation levels a significant distortion in the electric field is observed even at room temperature which matches well the predicted theoretical model.

  10. Accurate X-Ray Spectral Predictions: An Advanced Self-Consistent-Field Approach Inspired by Many-Body Perturbation Theory

    International Nuclear Information System (INIS)

    Liang, Yufeng; Vinson, John; Pemmaraju, Sri; Drisdell, Walter S.; Shirley, Eric L.; Prendergast, David

    2017-01-01

    Constrained-occupancy delta-self-consistent-field (ΔSCF) methods and many-body perturbation theories (MBPT) are two strategies for obtaining electronic excitations from first principles. Using the two distinct approaches, we study the O 1s core excitations that have become increasingly important for characterizing transition-metal oxides and understanding strong electronic correlation. The ΔSCF approach, in its current single-particle form, systematically underestimates the pre-edge intensity for chosen oxides, despite its success in weakly correlated systems. By contrast, the Bethe-Salpeter equation within MBPT predicts much better line shapes. This motivates one to reexamine the many-electron dynamics of x-ray excitations. We find that the single-particle ΔSCF approach can be rectified by explicitly calculating many-electron transition amplitudes, producing x-ray spectra in excellent agreement with experiments. This study paves the way to accurately predict x-ray near-edge spectral fingerprints for physics and materials science beyond the Bethe-Salpether equation.

  11. Optically stimulated luminescence in x-ray irradiated xSnO-(25-x)SrO-75B2O3 glass

    Science.gov (United States)

    Nanto, H.; Nakagawa, R.; Takei, Y.; Hirasawa, K.; Miyamoto, Y.; Masai, H.; Kurobori, T.; Yanagida, T.; Fujimoto, Y.

    2015-06-01

    An intense optically stimulated luminescence (OSL) was observed, for the first time, in x-ray irradiated xSnO-(25-x)SrO-75B2O3 glass. It was found that the peak wavelength of OSL emission spectrum and its stimulation spectrum is about 400 nm and 600 nm, respectively. The OSL intensity is depended on the SnO contents (x=0.05-1.5) and the most intense OSL was observed in 1.0 mol% SnO doped glass. It was found that the OSL intensity is increased with increasing x-ray absorbed dose. Fairly good fading characteristics were observed in the x-ray irradiated glass, showing that this glass is useful as a candidate for OSL sensor materials for ionizing radiation monitoring.

  12. Naturally irradiated fluorite as a historic violet pigment: Raman spectroscopic and X-ray diffraction study

    Czech Academy of Sciences Publication Activity Database

    Čermáková, Zdeňka; Bezdička, Petr; Němec, I.; Hradilová, J.; Šrein, V.; Blažek, Jan; Hradil, David

    2015-01-01

    Roč. 46, č. 2 (2015), s. 236-243 ISSN 0377-0486 R&D Projects: GA ČR GAP103/12/2211 Institutional support: RVO:61388980 ; RVO:67985556 Keywords : fluorite * pigment * fluorescence bands * diffraction lines broadening * irradiation Subject RIV: CA - Inorganic Chemistry Impact factor: 2.395, year: 2015

  13. Chromosomes and irradiation: in vitro study of the action of X-rays on human lymphocytes

    International Nuclear Information System (INIS)

    Mouriquand, C.; Patet, J.; Gilly, C.; Wolff, C.

    1966-01-01

    Radioinduced chromosomal aberrations were studied in vitro on leukocytes of human peripheral blood after x irradiation at 25, 50, 100, 200, and 300 R. The numeric and structural anomalies were examined on 600 karyotypes. The relationship between these disorders and the dose delivered to the blood are discussed. An explanation on their mechanism of formation is tentatively given. (authors) [fr

  14. Neutron and X-ray diffraction analysis of the effect of irradiation dose and temperature on microstructure of irradiated HT-9 steel

    Science.gov (United States)

    Mosbrucker, P. L.; Brown, D. W.; Anderoglu, O.; Balogh, L.; Maloy, S. A.; Sisneros, T. A.; Almer, J.; Tulk, E. F.; Morgenroth, W.; Dippel, A. C.

    2013-11-01

    Material harvested from several positions within a nuclear fuel duct (the ACO-3 duct) used in a 6-year irradiation of a fuel assembly in the Fast Flux Test Reactor Facility (FFTF) was examined using neutron and high-energy X-ray diffraction. Samples with a wide range of irradiation dose and irradiation temperature history, reaching doses of up to 147 dpa and temperatures of up to 777 K, were examined. The response of various microstructural characteristics such as the weight fraction of M23C6 carbides, the dislocation density and character, and the crystallographic texture were determined using whole profile analysis of the diffraction data and related to the macroscopic mechanical behavior. For instance, the dislocation density was observed to be intimately linked with observed flow strength of the irradiated materials, following the Taylor law. In general, at the high doses studied in this work, the irradiation temperature is the predominant controlling factor of the dislocation density and, thus, the flow strength of the irradiated material. The results, representing some of the first diffraction work done on samples exposed to such a high received dose, demonstrate how non-destructive and stand-off diffraction techniques can be used to characterize irradiation induced microstructure and at least estimate mechanical properties in irradiated materials without exposing workers to radiation hazards.

  15. Neutron and X-ray diffraction analysis of the effect of irradiation dose and temperature on microstructure of irradiated HT-9 steel

    International Nuclear Information System (INIS)

    Mosbrucker, P.L.; Brown, D.W.; Anderoglu, O.; Balogh, L.; Maloy, S.A.; Sisneros, T.A.; Almer, J.; Tulk, E.F.; Morgenroth, W.; Dippel, A.C.

    2013-01-01

    Material harvested from several positions within a nuclear fuel duct (the ACO-3 duct) used in a 6-year irradiation of a fuel assembly in the Fast Flux Test Reactor Facility (FFTF) was examined using neutron and high-energy X-ray diffraction. Samples with a wide range of irradiation dose and irradiation temperature history, reaching doses of up to 147 dpa and temperatures of up to 777 K, were examined. The response of various microstructural characteristics such as the weight fraction of M 23 C 6 carbides, the dislocation density and character, and the crystallographic texture were determined using whole profile analysis of the diffraction data and related to the macroscopic mechanical behavior. For instance, the dislocation density was observed to be intimately linked with observed flow strength of the irradiated materials, following the Taylor law. In general, at the high doses studied in this work, the irradiation temperature is the predominant controlling factor of the dislocation density and, thus, the flow strength of the irradiated material. The results, representing some of the first diffraction work done on samples exposed to such a high received dose, demonstrate how non-destructive and stand-off diffraction techniques can be used to characterize irradiation induced microstructure and at least estimate mechanical properties in irradiated materials without exposing workers to radiation hazards

  16. Pathological studies on carcinoma of the lung in rats induced by external x-ray irradiation

    International Nuclear Information System (INIS)

    Kodama, Tetsuro

    1978-01-01

    Lung tumors in Wistar rats were induced by administration of various doses of external irradiation through the anterior chest wall. Pulmonary fibrosis following external irradiation was observed in 13 of 17 rats (76.4%) in Group I (800R/day for 5 days), in 26 of 36 rats (78.8%) in Group II (800R/WK for 5 WKs), and in 6 of 18 rats (35.3%) in Group III (500R/WK for 4 WKs). The degree of pulmonary fibrosis was greater each time in the rats given 4,000R than in the rats given 2,000R. In Groups I and II 5 pulmonary tumors (2 squamous cell carcinomas, 1 adenocarcinoma, and 2 adenomas) were observed in 3 of 16 rats (17.6%), and 10 pulmonary tumors (4 squamous cell carcinomas, 1 adenocarcinoma, 4 adenomas, and 1 fibrosarcoma) were observed in 9 of 33 rats (24.2%), respectively. In Group III only 1 case of pulmonary adenoma was observed among 17 rats (6.8%). The first case of epithelial tumor of the lung was found in a rat in Group I. Histological findings during the course of the experiment revealed that the earliest changes following irradiation were those of radiation pneuminitis, characterized by engorged capillaries and edema in collapsed alveoli, with lymphocytic and plasma cell infiltrations. In addition, the nuclei of the lining cells of the alveoli and bronchioles were enlarged and atypical. From the 10th through the 20th experimental week, fibrosis of the alveolar septum and adenomatous hyperplasia of the alveolar lining became extensive, particularly in the bronchiolo-alveolar areas of the periphery of the lung. Atypical adenomatous hyperplasia occurred within the fibrotic lesion or in proximity to it. It was frequently followed by carcinoma, suggesting that carcinoma in the present experiment arose in atypical epithelium, induced by irradiation of the bronchiolo-alveolar epithelial lining

  17. Life-shortening and carcinogenesis in mice irradiated neonatally with x rays

    International Nuclear Information System (INIS)

    Sasaki, S.; Kasuga, T.

    1981-01-01

    The characteristics of life-shortening and carcinogenesis were investigated in x-irradiated neonatal B6WFr mice. Animals were irradiated with 24 hr after birth and allowed to complete their normal life span. Mean life span was shortened linearly with doses at a rate of 9.1% per 100 R for females and 9.8% for males. The spectrum of neoplastic diseases was apparently modulated by x irradiation, showing neonatal B6WFr mice to be highly susceptible to the induction of thymic lymphoma, liver tumor, and pituitary tumor. The dose-response relationship for thymice lymphoma could be described by a linear-quadratic model, and linearity could be rejected. Thymic lymphoma developed after a short latent period, resulting in death between 100 and 450 days of age. Liver and pituitary tumors increased with increasing dose up to 400 R and decreased thereafter. The latent period for liver tumor development was apparently shortened with increasing doses. Pituitary tumor developed in excess only in females after a long latent period

  18. X-ray Irradiation Control of Frankliniella occidentalis and Frankliniella intonsa (Thysanoptera: Thripidae) in the Exportation of Freshly Cut Lily Flowers.

    Science.gov (United States)

    Koo, Hyun-Na; Yun, Seung-Hwan; Kim, Hyun-Ju; Kim, Hyun Kyung; Kim, Gil-Hah

    2017-04-01

    Lily (Lilium longiflorum Thunb.) is the most representative bulb flower, and it is the third most important flower in the flower industry of South Korea after rose and chrysanthemum. To determine the efficacy of X-ray irradiation for use in quarantine processing, two species of flower thrips (Frankliniella intonsa (Trybom) and Frankliniella occidentalis (Pergande)) were placed in the top, middle, and bottom locations of lily boxes and irradiated with different X-ray doses. After irradiation with an X-ray dose of 150 Gy, the egg hatching of the two flower thrips was completely inhibited at every location in the lily boxes, and the irradiated F. intonsa and F. occidentalis nymphs failed to emerge as adult in every location of the lily boxes. When the adults were irradiated at 150 Gy, the fecundity of the two flower thrips was markedly lower than that of the untreated control groups. The F1 generation failed to hatch at the top and middle locations, whereas the F1 generation of both F. intonsa and F. occidentalis was not suppressed at the bottom locations, even at 200 Gy. However, hatching was perfectly inhibited at 300 Gy of X-ray irradiation. Also, X-rays did not affect the postharvest physiology of cut lilies. Therefore, a minimum dose of 300 Gy is recommended for the control of F. intonsa and F. occidentalis for the exportation of lily. © The Authors 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Proliferation kinetics of cultured cells after irradiation with X-rays and 14 MeV neutrons studied by time-lapse cinematography.

    Science.gov (United States)

    Kooi, M W; Stap, J; Barendsen, G W

    1984-06-01

    Exponentially growing cells of an established line derived from a mouse osteosarcoma (MOS) have been studied by time-lapse cinematography after irradiation with 3 Gy of 200 kV X-rays or 1.5 Gy of 14 MeV neutrons. Cell cycle times (Tc) of individual cells and their progeny in three subsequent generations as well as the occurrence of aberrant mitosis have been determined to evaluate the variation in expression of damage in relation to the stage in the intermitotic cycle and the radiation quality. The results show that the radiation doses applied cause an equal elongation of the mean Tc, which is largest in the irradiated cells but persists in the three subsequent generations. After 3 Gy of X-rays, mitotic delay is largest in cells irradiated in later stages of the cycle, but this difference is not observed after 1.5 Gy of 14 MeV neutrons. In subsequent generations the Tc values show larger variations among descendents of cells treated in the same stage of the cycle as compared to controls but this variation is equal for the doses of X-rays and neutrons applied. Division probability was significantly reduced in irradiated cells as well as in subsequent generations, whereby with neutrons as compared to X-rays the damage is expressed in earlier generations, with less variation as a function of the cell cycle.

  20. Proliferation kinetics of cultured cells after irradiation with X-rays and 14 MeV neutrons studied by time-lapse cinematography

    International Nuclear Information System (INIS)

    Kooi, M.W.; Stap, J.; Barendsen, G.W.

    1984-01-01

    Exponentially growing cells of an established line derived from a mouse osteosarcoma (MOS) have been studied by time-lapse cinematography after irradiation with 3 Gy of 200 kV X- rays or 1.5 Gy of 14 MeV neutrons. The results show that the radiation doses applied cause an equal elongation of the mean cell cycle time Tsub(c), which is largest in the irradiated cells but persists in the three subsequent generations. After 3 Gy of X-rays, mitotic delay is largest in cells irradiated in later stages of the cycle, but this difference is not observed after 1.5 Gy of 14 MeV neutrons. In subsequent generations the Tsub(c) values show larger variations among descendents of cells treated in the same stage of the cycle as compared to controls but this variation is equal for the doses of X-rays and neutrons applied. Division probability was significantly reduced in irradiated cells as well as in subsequent generations, whereas with neutrons as compared to X-rays the damage is expressed in earlier generations, with less variation as a function of the cell cycle. (author)

  1. Whole-body adipose tissue analysis: comparison of MRI, CT and dual energy X-ray absorptiometry

    DEFF Research Database (Denmark)

    Kullberg, J; Brandberg, J; Angelhed, J-E

    2009-01-01

    The aim of this study was to validate a recently proposed MRI-based T(1)-mapping method for analysis of whole-body adipose tissue (AT) using an established CT protocol as reference and to include results from dual energy X-ray absorptiometry (DEXA). 10 subjects, drawn from the Swedish Obese Subje......-processing of whole-body MRI data, allowing longitudinal whole-body studies that are also applicable for children and adolescents.......The aim of this study was to validate a recently proposed MRI-based T(1)-mapping method for analysis of whole-body adipose tissue (AT) using an established CT protocol as reference and to include results from dual energy X-ray absorptiometry (DEXA). 10 subjects, drawn from the Swedish Obese...... Subjects Sibling-pairs study, were examined using CT, MRI and DEXA. The CT analysis was based on 28 imaged slices. T(1) maps were calculated using contiguous MRI data from two different gradient echo sequences acquired using different flip angles. CT and MRI comparison was performed slice...

  2. MOX fuel irradiation behaviour: Results from X-ray microbeam analysis

    International Nuclear Information System (INIS)

    Walker, C.T.; Goll, W.; Matsumura, T.

    1997-01-01

    The behaviour of plutonium, xenon and caesium were investigated in two sections of irradiated MOX fuel produced by the OCOM process. In one fuel (OCOM30), the MOX agglomerates contained 18 wt% fissile plutonium, and had a low volume fraction of 0.17; in the other (OCOM15) the agglomerates contained 9 wt% fissile plutonium, and had a high volume fraction of 0.34. Both fuels had been irradiated under normal power reactor conditions to a burn-up of approximately 44 GWd/t. The main aim of the work was to establish whether the above differences in composition affected the percentage fission gas released by the fuels. Since U/Pu interdiffusion did not occurred during the irradiation, both fuels remained inhomogeneous on the microscopic scale. However, the concentration of plutonium in the MOX agglomerates decreases by about 50% as a result of fission, whereas the plutonium content of the UO 2 matrix increased by about a factor of four to approximately 2 wt% due to neutron capture by 238 U. The agglomerates in the OCOM15 fuel generally exhibited a finer structure due to the lower burn-up. More than 80% of the fission gas had been released from the oxide lattice of the MOX agglomerates in both fuels. However, a very high fraction of this gas precipitated and remained in the pore structure of the agglomerates. Consequently, puncturing revealed that for both fuels the percentage of gas released to the rod free volume increased from less than 0.5% at 10 GWd/t to a maximum of 3.5% at 45 GWd/t. The conclusion is that the percentage of gas released by MOX fuel is largely unaffected of the level of inhomogeneity of the fuel. In both fuels caesium showed near complete retention in both the MOX agglomerates and the UO 2 matrix. (author). 8 refs, 11 figs, 3 tabs

  3. Line X-ray emission from Al targets irradiated by high-intensity, variable-length laser pulses

    Czech Academy of Sciences Publication Activity Database

    Limpouch, J.; Renner, Oldřich; Krouský, Eduard; Uschmann, I.; Förster, E.; Kalashnikov, M. P.; Nickles, P. V.

    2002-01-01

    Roč. 20, - (2002), s. 43-49 ISSN 0263-0346 R&D Projects: GA ČR GA202/01/0755 Institutional research plan: CEZ:AV0Z1010921 Keywords : laser-produced plasma * line X-ray emission * X-ray sources * X-ray spectroscopy Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.487, year: 2002

  4. Delayed persistence of giant-nucleated cells induced by X-ray and proton irradiation in the progeny of replicating normal human f ibroblast cells

    Science.gov (United States)

    Almahwasi, A. A.; Jeynes, J. C.; Merchant, M. J.; Bradley, D. A.; Regan, P. H.

    2017-08-01

    Ionising radiation can induce giant-nucleated cells (GCs) in the progeny of irradiated populations, as demonstrated in various cellular systems. Most in vitro studies have utilised quiescent cancerous or normal cell lines but it is not clear whether radiation-induced GCs persist in the progeny of normal replicated cells. In the current work we show persistent induction of GCs in the progeny of normal human-diploid skin fibroblasts (AG1522). These cells were originally irradiated with a single equivalent clinical dose of 0.2, 1 or 2 Gy of either X-ray or proton irradiation and maintained in an active state for various post-irradiation incubation interval times before they were replated for GC analysis. The results demonstrate that the formation of GCs in the progeny of X-ray or proton irradiated cells was increased in a dose-dependent manner when measured 7 days after irradiation and this finding is in agreement with that reported for the AG1522 cells using other radiation qualities. For the 1 Gy X-ray doses it was found that the GC yield increased continually with time up to 21 days post-irradiation. These results can act as benchmark data for such work and may have important implications for studies aimed at evaluating the efficacy of radiation therapy and in determining the risk of delayed effects particularly when applying protons.

  5. Dose and induction to cancer risk evaluation associated to use of X ray body scanners by transmission at airports

    International Nuclear Information System (INIS)

    Correa, Samanda Cristine Arruda; Aquino, Josilto Oliveira de; Souza, Edmilson Monteiro de; Silva, Ademir Xavier da

    2011-01-01

    This paper uses the Monte Carlo MCNPX and the phantoms in male voxel and female voxel to evaluate the absorbed doses effective doses and the induction risk and the mortality due to cancer associated to exposures of individual submitted to X ray body scanners by transmission at various projections. The values of effective dose were calculated according to the recommended by the new ICRP 103 and the values of induction risks and mortality due to cancer were estimated through the document BEIR VII. (author)

  6. Gas bubble network formation in irradiated beryllium pebbles monitored by X-Ray micro-tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bolier, E; Ferrero, C. [Forschungszentrum Karlsruhe, Zimer 203, Gebaeude 451, Abteilung HVT-TL (Germany); Moslang, A. [Forschungszentrum Karlsruhe GmbH, FZK, Karlsruhe (Germany); Pieritz, R.A. [CNRS, Lab. de Glaciologie et Geophysique de l' Environnement, 38 - Saint Martin d' Heres (France)

    2007-07-01

    Full text of publication follows: The efficient and safe operation of helium cooled ceramic breeder blankets requires among others an efficient tritium release during operation at blanket relevant temperatures. In the past out-of-pile thermal desorption studies on low temperature neutron irradiated beryllium have shown that tritium and helium release peaks occur together. This phenomenon can be interpreted in terms of growth and coalescence of helium bubbles and tritium that either is trapped inside the helium bubbles in form of T{sub 2} molecules or in their strain field. With increasing temperature the bubble density and size at grain interfaces increase together with the probability of interconnected porosities and channel formation to the outer surface, leading to simultaneous helium and tritium release peaks in TDS. For a reliable prediction of gas release up to end-of-life conditions at blanket relevant temperatures, knowledge of the dynamics of bubble growth and coalescence as well as the 3D distribution of bubble network formation is indispensable. Such data could also be used to experimentally validate any future model predictions of tritium and helium release rates. A high resolution computer aided micro-tomography (CMT) setup has been developed at the European Synchrotron Radiation Facility which allowed reconstructing 3-D images of beryllium pebbles without damaging them. By postprocessing the data a 3D rendering of inner surfaces and of interconnected channel networks can be obtained, thus allowing the identification of open porosities in neutron irradiated and tempered beryllium pebbles. In our case Beryllium pebbles of 2 mm diameter had been neutron irradiated in the 'Beryllium' experiment at 770 K with 1.24 x 10{sup 25} nxm{sup -2} resulting in 480 appm He and 12 appm Tritium. After annealing at 1500 K CMT was performed on the pebbles with 4.9 and 1.4 {mu}m voxel resolution, respectively, followed by morphological and topological post

  7. Diagnostic accuracy of full-body linear X-ray scanning in multiple trauma patients in comparison to computed tomography

    International Nuclear Information System (INIS)

    Joeres, A.P.W.; Heverhagen, J.T.; Bonel, H.; Exadaktylos, A.; Klink, T.; Wuerzburg Univ.

    2016-01-01

    The purpose of this study was to evaluate the diagnostic accuracy of full-body linear X-ray scanning (LS) in multiple trauma patients in comparison to 128-multislice computed tomography (MSCT). 106 multiple trauma patients (female: 33; male: 73) were retrospectively included in this study. All patients underwent LS of the whole body, including extremities, and MSCT covering the neck, thorax, abdomen, and pelvis. The diagnostic accuracy of LS for the detection of fractures of the truncal skeleton and pneumothoraces was evaluated in comparison to MSCT by two observers in consensus. Extremity fractures detected by LS were documented. The overall sensitivity of LS was 49.2%, the specificity was 93.3%, the positive predictive value was 91%, and the negative predictive value was 57.5%. The overall sensitivity for vertebral fractures was 16.7%, and the specificity was 100%. The sensitivity was 48.7% and the specificity 98.2% for all other fractures. Pneumothoraces were detected in 12 patients by CT, but not by LS.40 extremity fractures were detected by LS, of which 4 fractures were dislocated, and 2 were fully covered by MSCT. The diagnostic accuracy of LS is limited in the evaluation of acute trauma of the truncal skeleton. LS allows fast whole-body X-ray imaging, and may be valuable for detecting extremity fractures in trauma patients in addition to MSCT.

  8. Diagnostic accuracy of full-body linear X-ray scanning in multiple trauma patients in comparison to computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Joeres, A.P.W.; Heverhagen, J.T.; Bonel, H. [Inselspital - University Hospital Bern (Switzerland). Univ. Inst. of Diagnostic, Interventional and Pediatric Radiology; Exadaktylos, A. [Inselspital - University Hospital Bern (Switzerland). Dept. of Emergency Medicine; Klink, T. [Inselspital - University Hospital Bern (Switzerland). Univ. Inst. of Diagnostic, Interventional and Pediatric Radiology; Wuerzburg Univ. (Germany). Inst. of Diagnostic and Interventional Radiology

    2016-02-15

    The purpose of this study was to evaluate the diagnostic accuracy of full-body linear X-ray scanning (LS) in multiple trauma patients in comparison to 128-multislice computed tomography (MSCT). 106 multiple trauma patients (female: 33; male: 73) were retrospectively included in this study. All patients underwent LS of the whole body, including extremities, and MSCT covering the neck, thorax, abdomen, and pelvis. The diagnostic accuracy of LS for the detection of fractures of the truncal skeleton and pneumothoraces was evaluated in comparison to MSCT by two observers in consensus. Extremity fractures detected by LS were documented. The overall sensitivity of LS was 49.2%, the specificity was 93.3%, the positive predictive value was 91%, and the negative predictive value was 57.5%. The overall sensitivity for vertebral fractures was 16.7%, and the specificity was 100%. The sensitivity was 48.7% and the specificity 98.2% for all other fractures. Pneumothoraces were detected in 12 patients by CT, but not by LS.40 extremity fractures were detected by LS, of which 4 fractures were dislocated, and 2 were fully covered by MSCT. The diagnostic accuracy of LS is limited in the evaluation of acute trauma of the truncal skeleton. LS allows fast whole-body X-ray imaging, and may be valuable for detecting extremity fractures in trauma patients in addition to MSCT.

  9. Structural shielding at irradiation tests with x-rays up to 400 kV

    International Nuclear Information System (INIS)

    Rabitsch, H.; Schachinger, E.

    1979-12-01

    Tables worked out in accordance to the dimensioning method following DIN 54113 are given for the determination protective barriers thicknesses against effective and stray radiation in practical operation conditions. The tables comprise irradiation operation with directional and non-directional radiation sources radiators beams collimated and are restricted to steel as dispersive material for the barrier thicknesses against stray radiation. The calculations of protective barriers against stray radiation show that operation with properly chosen primary beam limiting orifice yields in considerable savings in protective shield thickness when compared to operation without or with mismatched orifice to film size. It further shows a relative indifference against changes of the stray area (film size) or the focus - film sheet distance. The protective shield thickness for the most common exposure conditions calculated according to the Austrian Regulations for Radiation Protection are on the safe side when compared to protective barriere thicknesses calculated according to DIN 54113. (V.M.)

  10. Radiation induced muscositis as space flight risk. Model studies on X-ray and heavy ion irradiated typical oral mucosa models

    International Nuclear Information System (INIS)

    Tschachojan, Viktoria

    2014-01-01

    Humans in exomagnetospheric space are exposed to highly energetic heavy ion radiation which can be hardly shielded. Since radiation-induced mucositis constitutes a severe complication of heavy ion radiotherapy, it would also implicate a serious medical safety risk for the crew members during prolonged space flights such as missions to Moon or Mars. For assessment of risk developing radiation-induced mucositis, three-dimensional organotypic cultures of immortalized human keratinocytes and fibroblasts were irradiated with a 12 C particle beam at high energies or X-Rays. Immunofluorescence stainings were done from cryosections and radiation induced release of cytokines and chemokines was quantified by ELISA from culture supernatants. The major focuses of this study were on 4, 8, 24 and 48 hours after irradiation. The conducted analyses of our mucosa model showed many structural similarities with the native oral mucosa and authentic immunological responses to radiation exposure. Quantification of the DNA damage in irradiated mucosa models revealed about twice as many DSB after heavy-ion irradiation compared to X-rays at definite doses and time points, suggesting a higher gene toxicity of heavy ions. Nuclear factor κB activation was observed after treatment with X-rays or 12 C particles. An activation of NF κB p65 in irradiated samples could not be detected. ELISA analyses showed significantly higher interleukin 6 and interleukin 8 levels after irradiation with X-rays and 12 C particles compared to non-irradiated controls. However, only X-rays induced significantly higher levels of interleukin 1β. Analyses of TNF-α and IFN-γ showed no radiation-induced effects. Further analyses revealed a radiation-induced reduction in proliferation and loss of compactness in irradiated oral mucosa model, which would lead to local lesions in vivo. In this study we revealed that several pro-inflammatory markers and structural changes are induced by X-rays and heavy-ion irradiation

  11. Nanoplasma dynamics of single large xenon clusters irradiated with superintense x-ray pulses from the linac coherent light source free-electron laser.

    Science.gov (United States)

    Gorkhover, T; Adolph, M; Rupp, D; Schorb, S; Epp, S W; Erk, B; Foucar, L; Hartmann, R; Kimmel, N; Kühnel, K-U; Rolles, D; Rudek, B; Rudenko, A; Andritschke, R; Aquila, A; Bozek, J D; Coppola, N; Erke, T; Filsinger, F; Gorke, H; Graafsma, H; Gumprecht, L; Hauser, G; Herrmann, S; Hirsemann, H; Hömke, A; Holl, P; Kaiser, C; Krasniqi, F; Meyer, J-H; Matysek, M; Messerschmidt, M; Miessner, D; Nilsson, B; Pietschner, D; Potdevin, G; Reich, C; Schaller, G; Schmidt, C; Schopper, F; Schröter, C D; Schulz, J; Soltau, H; Weidenspointner, G; Schlichting, I; Strüder, L; Ullrich, J; Möller, T; Bostedt, C

    2012-06-15

    The plasma dynamics of single mesoscopic Xe particles irradiated with intense femtosecond x-ray pulses exceeding 10(16)  W/cm2 from the Linac Coherent Light Source free-electron laser are investigated. Simultaneous recording of diffraction patterns and ion spectra allows eliminating the influence of the laser focal volume intensity and particle size distribution. The data show that for clusters illuminated with intense x-ray pulses, highly charged ionization fragments in a narrow distribution are created and that the nanoplasma recombination is efficiently suppressed.

  12. Growing central axons deprived of normal target neurones by neonatal X-ray irradiation still terminate in a precisely laminated fashion

    International Nuclear Information System (INIS)

    Laurberg, S.; Hjorth-Simonsen, A.

    1977-01-01

    Some studies are described on rat pups. The object was to study the fate of axons that normally terminate in a highly selective laminar fashion in the molecular layer of the medial limb of the dentate gyrus of the mammalian cerebral cortex when this is removed by neonatal X-ray irradiation. The rats were shielded with Pb, except for a field above the hippocampus and the dentate gyrus, and exposed to X-rays from a 250 kV source at a distance of 34 cm. (U.K.)

  13. In-situ small-angle x-ray scattering study of nanoparticles in the plasma plume induced by pulsed laser irradiation of metallic targets

    Energy Technology Data Exchange (ETDEWEB)

    Lavisse, L.; Jouvard, J.-M.; Girault, M.; Potin, V.; Andrzejewski, H.; Marco de Lucas, M. C.; Bourgeois, S. [Laboratoire Interdisciplinaire Carnot de Bourgogne (ICB), UMR 6303 CNRS-Universite de Bourgogne, 9 Avenue A. Savary, BP 47870-21078 Dijon Cedex (France); Le Garrec, J.-L.; Carles, S.; Mitchell, J. B. A. [Institut de Physique de Rennes, UMR 6251 CNRS-Universite de Rennes 1, 35042 Rennes Cedex (France); Hallo, L. [CEA CESTA, 15 Avenue des Sablieres CS 60001, 33116 Le Barp Cedex (France); Perez, J. [Synchrotron SOLEIL, L' Orme des Merisiers, Saint-Aubin, F-91192 Gif-sur-Yvette Cedex (France); Decloux, J. [Kaluti System, Optique et Laser, Centre Scientifique d' Orsay, 91400 Orsay (France)

    2012-04-16

    Small angle x-ray scattering was used to probe in-situ the formation of nanoparticles in the plasma plume generated by pulsed laser irradiation of a titanium metal surface under atmospheric conditions. The size and morphology of the nanoparticles were characterized as function of laser irradiance. Two families of nanoparticles were identified with sizes on the order of 10 and 70 nm, respectively. These results were confirmed by ex-situ transmission electron microscopy experiments.

  14. A short note on physical properties to irradiated nuclear fuel by means of X-ray diffraction and neutron scattering techniques

    Science.gov (United States)

    Abdullah, Yusof; Husain, Hishamuddin; Hak, Cik Rohaida Che; Alias, Nor Hayati; Yusof, Mohd Reusmaazran; Kasim, Norasiah Ab; Zali, Nurazila Mat; Mohamed, Abdul Aziz

    2015-04-01

    For nuclear reactor applications, understanding the evolution of the fuel materials microstructure during irradiation are of great importance. This paper reviews the physical properties of irradiated nuclear fuel analysis which are considered to be of most importance in determining the performance behavior of fuel. X-rays diffraction was recognize as important tool to investigate the phase identification while neutron scattering analyses the interaction between uranium and other materials and also investigation of the defect structure.

  15. A short note on physical properties to irradiated nuclear fuel by means of X-ray diffraction and neutron scattering techniques

    Energy Technology Data Exchange (ETDEWEB)

    Abdullah, Yusof, E-mail: yusofabd@nuclearmalaysia.gov.my; Husain, Hishamuddin; Hak, Cik Rohaida Che; Alias, Nor Hayati; Yusof, Mohd Reusmaazran; Kasim, Norasiah Ab; Zali, Nurazila Mat [Malaysian Nuclear Agency, Bangi, Kajang 43000, Selangor (Malaysia); Mohamed, Abdul Aziz [College of Engineering, Universiti Tenaga National, Jalan Ikram-Uniten, 43000 Kajang, Selangor (Malaysia)

    2015-04-29

    For nuclear reactor applications, understanding the evolution of the fuel materials microstructure during irradiation are of great importance. This paper reviews the physical properties of irradiated nuclear fuel analysis which are considered to be of most importance in determining the performance behavior of fuel. X-rays diffraction was recognize as important tool to investigate the phase identification while neutron scattering analyses the interaction between uranium and other materials and also investigation of the defect structure.

  16. Skull x-ray

    Science.gov (United States)

    X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  17. Neck x-ray

    Science.gov (United States)

    X-ray - neck; Cervical spine x-ray; Lateral neck x-ray ... There is low radiation exposure. X-rays are monitored so that the lowest amount of radiation is used to produce the image. Pregnant women and ...

  18. Evaluation of the impacts of the use of X-Ray body inspection technology in the Brazilian prison system

    International Nuclear Information System (INIS)

    Nante, T.A.; Lima, C.M. Araujo de; Lima, A.R.

    2017-01-01

    The crisis of the Brazilian Penitentiary System is visible with overcrowding, the appearance and growth of criminal factions, the lack of infrastructure of prisons, etc. This scenario led to the adoption of new technologies, such as the body inspection by X-rays, known as Body scanners. The technology is capable of detecting various illicit objects hidden under clothes or even in the pockets of individuals searched, following the recommendation of the National Council of Criminal and Penitentiary Policy, allowing a more effective search and the extinction of the intimate searches. The objective of this study is to evaluate the social impacts of the use of body inspection technology in prison units, including aspects of radiological protection related to operation and maintenance

  19. X-ray diffraction apparatus

    International Nuclear Information System (INIS)

    Padini, F.R.

    1978-01-01

    The invention provides an x-ray diffraction apparatus permitting the rotation of the divergence sit in conjunction with the rotation of the x-ray irradiated specimen, whereby the dimensions of the x-ray irradiated portion of the specimen remain substantially constant during the rotation of the specimen. In a preferred embodiment, the divergence slit is connected to a structural element linked with a second structural element connected to the specimen such that the divergence slit rotates at a lower angular speed than the specimen

  20. Computational modelling of the cerebral cortical microvasculature: effect of x-ray microbeams versus broad beam irradiation

    Science.gov (United States)

    Merrem, A.; Bartzsch, S.; Laissue, J.; Oelfke, U.

    2017-05-01

    Microbeam Radiation Therapy is an innovative pre-clinical strategy which uses arrays of parallel, tens of micrometres wide kilo-voltage photon beams to treat tumours. These x-ray beams are typically generated on a synchrotron source. It was shown that these beam geometries allow exceptional normal tissue sparing from radiation damage while still being effective in tumour ablation. A final biological explanation for this enhanced therapeutic ratio has still not been found, some experimental data support an important role of the vasculature. In this work, the effect of microbeams on a normal microvascular network of the cerebral cortex was assessed in computer simulations and compared to the effect of homogeneous, seamless exposures at equal energy absorption. The anatomy of a cerebral microvascular network and the inflicted radiation damage were simulated to closely mimic experimental data using a novel probabilistic model of radiation damage to blood vessels. It was found that the spatial dose fractionation by microbeam arrays significantly decreased the vascular damage. The higher the peak-to-valley dose ratio, the more pronounced the sparing effect. Simulations of the radiation damage as a function of morphological parameters of the vascular network demonstrated that the distribution of blood vessel radii is a key parameter determining both the overall radiation damage of the vasculature and the dose-dependent differential effect of microbeam irradiation.

  1. Chromosomal damage and mitotic index in Bosnian and Herzegovinian mountain horse lymphocytes following low dosage X-ray irradiation in vitro

    International Nuclear Information System (INIS)

    Rukavina, D.; Hasanbašić, D.; Katica, A.; Suljkanović, E.

    2009-01-01

    In this study we investigated the influence of low dosage X-ray irradiation on the incidence of chromosomal damage and changes in mitotic index (MI) in cultured peripheral lymphocytes of Bosnian and Herzegovinian mountain horse following in vitro irradiation. X-ray irradiation induced a dose-dependent decrease in MI but only the dose of 0.5 Gy induced a significant decrease in comparison with the control and other dose groups. The analysis the chromosomal damage revealed a clear dose-dependent increase in the incidence of chromosomal damage per metaphase. Significant differences were detected by analysis of variance and the LSD test confirmed significant differences between cell that received 0.2 Gy and 0.5 Gy when compared to the control cells and cells that received 0.1 Gy. However, Scheeffes' test assigned significance only to the differences established between the cells that received 0.5 Gy and the other groups of lymphocytes

  2. Effect of X-ray irradiation on germination of rice and wheat at different temperatures and pH levels of water

    International Nuclear Information System (INIS)

    Rajput, T.B.S.; Singh, Jaswant

    1981-01-01

    An experiment was conducted on the germination of ''Jaya'' rice (Oryza sativa Linn.) and ''Sonalika'' wheat (Triticum aestivum Linn. emend. Thell.) to study the effects of low doses of X-ray irradiation at different temperatures and pH levels of water. The percentage of germination was more at pH 7, and decreased with an increase or decrease in pH level. In most of the cases irradiation delayed the germination and proved to be harmful. But at 20deg C, 4 KR X-ray irradiation promoted the germination of rice by more than 15% at pH levels of 5.5-8.5. But in wheat no significant increase in germination percentage was noted at any combination of the parameters. (auth.)

  3. Clustering of DSB in DNA by X-Ray and a-particle irradiation in MCF-7 cells studied with anti γ-H2AX

    International Nuclear Information System (INIS)

    Tapia, O.; Soto, J.; Castro, F.A.; Berciano, Ma T; Lafarga, M.; Cos, S.; Sanchez-Barcelo, E.

    2007-01-01

    Among the effects produced by the ionizing radiations in cellular DNA, double strand breaks (DSB) are considered particularly important. These ruptures and their grouping in certain points, clustering, are acknowledged as the cause for mutagenic effects and cellular death. In this work we present the methodology and the results of the application of the DSB - DNA marking technique by using anti γ-H2AX, taking human cancerous cells MCF-7 as model and X-rays and a particles as irradiation agents. The obtained results are showed in a qualitative way like a set of figures. Are shows the effects of a dose of 2 Gy X-rays in the DSB - DNA after 30 minutes of the irradiation that responds to a certain pattern in which a spatially homogenous irradiation interacts with the DNA. As in previous case, the effects of X-rays in the DSB - DNA shows a different pattern affecting the cells that are in mitosis. Also, the effects of a dose of 2 Gy X-rays obtained after 24 hours of irradiation shows a number of DSB smaller, which is indicative of the repairing process. The results of the irradiation with a dose of 0.1 Gy originated from a particles cause a smaller number of DSB. Nevertheless, the existence of a bigger clustering with the appearance of clearly more intense points is appraised. Also, the effect of the irradiation is showed as an aligned trace of clusters that is possible to attribute to the passing of a a particle through the cellular nucleus. (Author)

  4. Relative Biologic Effectiveness (RBE) of 50 kV X-rays Measured in a Phantom for Intraoperative Tumor-Bed Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Qi; Schneider, Frank; Ma, Lin; Wenz, Frederik [Department of Radiation Oncology, Universitätsmedizin Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim (Germany); Herskind, Carsten, E-mail: carsten.herskind@medma.uni-heidelberg.de [Department of Radiation Oncology, Universitätsmedizin Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim (Germany)

    2013-03-15

    Purpose: Intraoperative radiation therapy (IORT) with low-energy x-rays is used to treat the tumor bed during breast-conserving surgery. The purpose was to determine the relative biologic effectiveness (RBE) of 50-kV x-rays for inactivation of cells irradiated in a tumor-bed phantom. Methods and Materials: The RBE was determined for clonogenic inactivation of human tumor and normal cells (MCF7, human umbilical vein endothelial cells, normal skin fibroblasts), and hamster V79 cells. The 50-kV x-rays from the Intrabeam machine (Carl Zeiss Surgical) with a spherical 4-cm applicator were used. Cells were irradiated in a water-equivalent phantom at defined distances (8.1-22.9 mm) from the applicator surface. The 50-kV x-rays from a surface therapy machine (Dermopan, Siemens) were included for comparison; 6-MV x-rays were used as reference radiation. Results: At 8.1-mm depth in the phantom (dose rate 15.1 Gy/h), mean RBE values of 50-kV x-rays from Intrabeam were 1.26 to 1.42 for the 4 cell types at doses yielding surviving fractions in the range of 0.01 to 0.5. Confidence intervals were in the range of 1.2 and 1.5. Similar RBE values were found for 50-kV x-rays from Dermopan for V79 (1.30, CI 1.25-1.36, P=.74) and GS4 (1.42, CI 1.30-1.54, P=.67). No significant dependence of RBE on dose was found for Intrabeam, but RBE decreased at a larger distance (12.7 mm; 9.8 Gy/h). Conclusions: An increased clinically relevant RBE was found for cell irradiation with Intrabeam at depths in the tumor bed targeted by IORT. The reduced RBE values at larger distances may be related to increased repair of sublethal damage during protracted irradiation or to hardening of the photon beam energy.

  5. Total body bone mineral density changes in healthy Japanese children as assessed by dual energy X-ray absorptiometry

    Energy Technology Data Exchange (ETDEWEB)

    Osamura, Toshio; Ono, Kunihiko; Funaki, Hidenori; Fujita, Hiromi; Kidowaki, Takuro; Kiyosawa, Nobuyuki; Mizuta, Ryuzo (Kyoto Second Red Cross Hospital (Japan)); Hanayasu, Hajime; Yoshioka, Hiroshi

    1993-10-01

    For 68 healthy children (38 male and 30 female) ranging in age from 1 to 16 years, we measured the bone mineral density (BMD) of different regions (skull, upper extremities, ribs, thoracic spine, lumbar spine, pelvis and lower extremities) and the total body BMD using a dual energy X-ray absorptiometry (DEXA; QDR-1000/W, Hologic Co.). The total body BMD increased linearly with age for both sexes (male: r=0.9501, female: r=0.9715; p<0.0001). The increase was more prominent in boys compared to girls. There was also a positive correlation between the ratio of total body bone mineral content to lean body mass and age, although total body BMD showed a stronger correlation with age. Furthermore, the total body BMD correlated highly with body height and weight. There were positive correlations between the BMD of different regions and age. Specifically, the BMD of the lower extremities correlated strongly with age. In addition, the BMD of the skull increased at the highest rate. Considering convenience, accuracy and precision, measurement time, radiation exposure dose and the strong correlation with age, measurement of the total body BMD by DEXA is thought to be an effective method of quantifying bone mineral, useful in the evaluation of bone metabolism kinetics in children. (author).

  6. Proton irradiation experiment for x-ray charge-coupled devices of the monitor of all-sky x-ray image mission onboard the international space station. 2. Degradation of dark current and identification of electron trap level

    CERN Document Server

    Miyata, E; Kamiyama, D

    2003-01-01

    We have investigated the radiation damage effects on a charge-coupled device (CCD) to be used for the Japanese X-ray mission, the monitor of all-sky X-ray image (MAXI), onboard the international space station (ISS). A temperature dependence of the dark current as a function of incremental dose is studied. We found that the protons having energy of >292 keV seriously increased the dark current of the devices. In order to improve the radiation tolerance of the devices, we have developed various device architectures to minimize the radiation damage in orbit. Among them, nitride oxide enables us to reduce the dark current significantly and therefore we adopted nitride oxide for the flight devices. We also compared the dark current of a device in operation and that out of operation during the proton irradiation. The dark current of the device in operation became twofold that out of operation, and we thus determined that devices would be turned off during the passage of the radiation belt. The temperature dependenc...

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... to produce pictures of any bone in the body. It is commonly used to diagnose fractured bones ... x-rays involves exposing a part of the body to a small dose of ionizing radiation to ...

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different parts of the body absorb the x-rays in varying degrees. Dense ...

  9. Cerium oxide nanoparticles: influence of the high-Z component revealed on radioresistant 9L cell survival under X-ray irradiation.

    Science.gov (United States)

    Briggs, Adam; Corde, Stéphanie; Oktaria, Sianne; Brown, Ryan; Rosenfeld, Anatoly; Lerch, Michael; Konstantinov, Konstantin; Tehei, Moeava

    2013-10-01

    This article pioneers a study into the influence of the high-Z component of nanoparticles on the efficacy of radioprotection some nanoparticles offer to exposed cells irradiated with X-rays. We reveal a significant decrease in the radioprotection efficacy for cells exposed to CeO2 nanoparticles and irradiated with 10 MV and 150 kVp X-rays. In addition, analysis of the 150 kVp survival curve data indicates a change in radiation quality, becoming more lethal for irradiated cells exposed to CeO2 nanoparticles. We attribute the change in efficacy to an increase in high linear energy transfer Auger electron production at 150 kVp which counterbalances the CeO2 nanoparticle radioprotection capability and locally changes the radiation quality. This study highlights an interesting phenomenon that must be considered if radiation protection drugs for use in radiotherapy are developed based on CeO2 nanoparticles. CeO2 nanoparticles are thought to offer radioprotection; however, this study reveals significant decrease in the radioprotection efficacy for cells exposed to CeO2 nanoparticles and irradiated with 10 MV and 150 kVp X-rays. This phenomenon must be considered when developing radiation protection drugs based on CeO2 nanoparticles. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.

  10. Change in fat-free mass assessed by bioelectrical impedance, total body potassium and dual energy X-ray absorptiometry during prolonged weight loss

    DEFF Research Database (Denmark)

    Hendel, H W; Gotfredsen, A; Højgaard, L

    1996-01-01

    A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK). These measu...

  11. Body composition in heavy smokers: comparison of segmental bioelectrical impedance analysis and dual-energy X-ray absorptiometry.

    Science.gov (United States)

    Rom, O; Reznick, A Z; Keidar, Z; Karkabi, K; Aizenbud, D

    2015-01-01

    Smokers tend to have lower body mass index, on one hand, and increased abdominal obesity, on the other hand. Also, low levels of lean mass (LM) and bone mineral content (BMC) were found among older smokers compared with non-smokers. This altered body composition and its consequences raise the need for simple and reliable methods for assessment of body composition in smokers. This study aimed to compare body composition assessment by segmental bioelectrical impedance analysis (sBIA) with the reference method, dual energy X-ray absorptiometry (DEXA). Body composition was measured by sBIA (Tanita BC-545) and DEXA (Hologic) in 49 heavy smokers (>15 cigarettes/day, mean age 43.8±12.0). The comparison included correlations and differences between measurements obtained using the two methods as well as the Blande-Altman analysis. Whole-body fat mass (FM) and LM measured by the two methods were found to be highly correlated (r>0.9, p0.9, p<0.001). However, sBIA significantly overestimated LM of the trunk and legs and underestimated the appendicular FM percentage. Verified by DEXA, sBIA provides reliable measures of whole-body LM, FM, and trunk FM in heavy smokers. A lesser degree of agreement was found for BMC, appendicular LM, and FM.

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. ...

  13. Modeling the shape and composition of the human body using dual energy X-ray absorptiometry images.

    Science.gov (United States)

    Shepherd, John A; Ng, Bennett K; Fan, Bo; Schwartz, Ann V; Cawthon, Peggy; Cummings, Steven R; Kritchevsky, Stephen; Nevitt, Michael; Santanasto, Adam; Cootes, Timothy F

    2017-01-01

    There is growing evidence that body shape and regional body composition are strong indicators of metabolic health. The purpose of this study was to develop statistical models that accurately describe holistic body shape, thickness, and leanness. We hypothesized that there are unique body shape features that are predictive of mortality beyond standard clinical measures. We developed algorithms to process whole-body dual-energy X-ray absorptiometry (DXA) scans into body thickness and leanness images. We performed statistical appearance modeling (SAM) and principal component analysis (PCA) to efficiently encode the variance of body shape, leanness, and thickness across sample of 400 older Americans from the Health ABC study. The sample included 200 cases and 200 controls based on 6-year mortality status, matched on sex, race and BMI. The final model contained 52 points outlining the torso, upper arms, thighs, and bony landmarks. Correlation analyses were performed on the PCA parameters to identify body shape features that vary across groups and with metabolic risk. Stepwise logistic regression was performed to identify sex and race, and predict mortality risk as a function of body shape parameters. These parameters are novel body composition features that uniquely identify body phenotypes of different groups and predict mortality risk. Three parameters from a SAM of body leanness and thickness accurately identified sex (training AUC = 0.99) and six accurately identified race (training AUC = 0.91) in the sample dataset. Three parameters from a SAM of only body thickness predicted mortality (training AUC = 0.66, validation AUC = 0.62). Further study is warranted to identify specific shape/composition features that predict other health outcomes.

  14. Validity of dual X-ray absorptiometry scanning for determination of body composition in IDDM patients

    DEFF Research Database (Denmark)

    Rosenfalck, A M; Almdal, Thomas Peter; Gotfredsen, A

    1995-01-01

    mass in IDDM patients and control subjects, as compared to other reference methods, i.e. total body potassium by 40K whole body counting (TBK), total body water by tritiated water (TBW), bioelectrical impedance analysis (BIA) and 24-h urinary creatinine excretion (Ucrea). A total of 13 healthy controls...

  15. Titanium peroxide nanoparticles enhanced cytotoxic effects of X-ray irradiation against pancreatic cancer model through reactive oxygen species generation in vitro and in vivo

    International Nuclear Information System (INIS)

    Nakayama, Masao; Sasaki, Ryohei; Ogino, Chiaki; Tanaka, Tsutomu; Morita, Kenta; Umetsu, Mitsuo; Ohara, Satoshi; Tan, Zhenquan; Nishimura, Yuya; Akasaka, Hiroaki; Sato, Kazuyoshi; Numako, Chiya; Takami, Seiichi; Kondo, Akihiko

    2016-01-01

    Biological applications of nanoparticles are rapidly increasing, which introduces new possibilities to improve the efficacy of radiotherapy. Here, we synthesized titanium peroxide nanoparticles (TiOxNPs) and investigated their efficacy as novel agents that can potently enhance the effects of radiation in the treatment of pancreatic cancer. TiOxNPs and polyacrylic acid-modified TiOxNPs (PAA-TiOxNPs) were synthesized from anatase-type titanium dioxide nanoparticles (TiO 2 NPs). The size and morphology of the PAA-TiOxNPs was evaluated using transmission electron microscopy and dynamic light scattering. The crystalline structures of the TiO 2 NPs and PAA-TiOxNPs with and without X-ray irradiation were analyzed using X-ray absorption. The ability of TiOxNPs and PAA-TiOxNPs to produce reactive oxygen species in response to X-ray irradiation was evaluated in a cell-free system and confirmed by flow cytometric analysis in vitro. DNA damage after X-ray exposure with or without PAA-TiOxNPs was assessed by immunohistochemical analysis of γ-H2AX foci formation in vitro and in vivo. Cytotoxicity was evaluated by a colony forming assay in vitro. Xenografts were prepared using human pancreatic cancer MIAPaCa-2 cells and used to evaluate the inhibition of tumor growth caused by X-ray exposure, PAA-TiOxNPs, and the combination of the two. The core structures of the PAA-TiOxNPs were found to be of the anatase type. The TiOxNPs and PAA-TiOxNPs showed a distinct ability to produce hydroxyl radicals in response to X-ray irradiation in a dose- and concentration-dependent manner, whereas the TiO 2 NPs did not. At the highest concentration of TiOxNPs, the amount of hydroxyl radicals increased by >8.5-fold following treatment with 30 Gy of radiation. The absorption of PAA-TiOxNPs enhanced DNA damage and resulted in higher cytotoxicity in response to X-ray irradiation in vitro. The combination of the PAA-TiOxNPs and X-ray irradiation induced significantly stronger tumor growth inhibition

  16. Estimation of percentage body fat by dual-energy x-ray absorptiometry: evaluation by in vivo human elemental composition

    Science.gov (United States)

    Wang, ZiMian; Heymsfield, Steven B; Chen, Zhao; Zhu, Shankuan; Pierson, Richard N

    2010-01-01

    Dual-energy x-ray absorptiometry (DXA) is widely applied for estimating body fat. The percentage of body mass as fat (%fat) is predicted from a DXA-estimated RST value defined as the ratio of soft tissue attenuation at two photon energies (e.g., 40 keV and 70 keV). Theoretically, the RST concept depends on the mass of each major element in the human body. The DXA RST values, however, have never been fully evaluated by measured human elemental composition. The present investigation evaluated the DXA RST value by the total body mass of 11 major elements and the DXA %fat by the five-component (5C) model, respectively. Six elements (i.e. C, N, Na, P, Cl and Ca) were measured by in vivo neutron activation analysis, and potassium (i.e. K) by whole-body 40K counting in 27 healthy adults. Models were developed for predicting the total body mass of four additional elements (i.e. H, O, Mg and S). The elemental content of soft tissue, after correction for bone mineral elements, was used to predict the RST values. The DXA RST values were strongly associated with the RST values predicted from elemental content (r = 0.976, P composition, and the present study supports the underlying physical concept and accuracy of the DXA method for estimating %fat. PMID:20393230

  17. A Threshold Exists in the Dose-response Relationship for Somatic Mutation Frequency Inducted by X-ray Irradiation of Drosophia

    International Nuclear Information System (INIS)

    Koana, T.; Takashima, Y.; Okada, M. O.; Ikehata, M.; Miyakoshi, J.; Sakai, K.

    2004-01-01

    The dose-response relationship of ionizing radiation and its stochastic effects has been thought to be linear without any thresholds. The basic data for this model was obtained from mutational assays in the male germ cells of fruits fly Drosophila melanogaster. However, carcinogenic activity should be examined more appropriately in somatic cells than in germ cells. Here, the dose-response relationship of X- ray irradiation and somatic mutation is examined in Drosophila. A threshold at approximately 1Gy was observed in the DNA repair proficient flies. In the repair deficient siblings, the threshold was smaller and the inclination of the dose-response curve was much steeper. These results suggest that the dose-response relationship between X-ray irradiation and somatic mutation has a threshold, and that the DNA repair function contributes to its formation. (Author) 35 refs

  18. Analysis of structural and numerical chromosomal anomalies at the first, second, and third mitosis after irradiation of one-cell mouse embryos with X-rays or neutrons

    International Nuclear Information System (INIS)

    Weissenborn, U.; Streffer, C.

    1988-01-01

    One-cell mouse embryos were irradiated with X-rays or neutrons. Analysis of the first, second, and third postradiation mitoses revealed yields of structural aberrations increasing linearly after exposure to both radiation qualities. For X-rays aberration frequency decreased from first to third mitosis; after neutrons it decreased from first to second mitosis but then increased in the third. RBEs of 4.7, 4.8, and 7.4 were calculated for corresponding mitoses. New aberrations were produced after the first postradiation mitosis and expressed during the second and third mitosis. Chromosome loss also increased with increasing radiation dose at the second mitosis. An RBE of 2 was calculated for this effect. Comparing the data with previous investigations on embryonic and fetal death after prenatal irradiation, it was concluded that the high radiosensitivity of the one-cell embryo is due to the induction of structural as well as of numerical chromosome aberrations. (author)

  19. Strong soft X-ray emission from a double-stream gas puff target irradiated with a nanosecond Nd:YAG laser

    Energy Technology Data Exchange (ETDEWEB)

    Fiedorowicz, H.; Bartnik, A.; Rakowski, R.; Szczurek, M. [Military Univ. of Technology, Warsaw (Poland). Inst. of Optoelectronics; Daido, H.; Suzuki, M.; Yamagami, S.; Choi, I.W.; Tang, H.J. [Osaka Univ., Suita (Japan). Inst. of Laser Engineering

    2001-07-01

    Soft X-ray emission from a new double-stream gas puff target irradiated with a nanosecond, high-power Nd:YAG laser pulse has been studied. The target was formed by pulsed injection of gas into a hollow gas stream made from helium by using a double-nozzle setup. Strong X-ray emissions near 10 nm from the double-stream krypton/helium, near 11 nm from the xenon/helium, and at 13 nm from the oxygen/helium targets were observed. The emission from the double-stream gas puff target was several times higher as compared to the ordinary gas puff targets, and comparable to the emission from the solid targets irradiated in the same conditions. (orig.)

  20. Real-time observation of irradiated Hela-cell Modified by Fluorescent ubiquitination-based Cell Cycle Indicator Using Synchrotron X-Ray Microbeam

    International Nuclear Information System (INIS)

    Narita, A.; Noguchi, M.; Kaminaga, K.; Yokoya, A.; Kobayashi, K.; Usami, N.; Fujii, K.

    2015-01-01

    Fluorescent ubiquitination-based cell-cycle indicator (FUCCI) human cancer (HeLa) cells (red indicates G1; green, S/G2) were exposed to a synchrotron X-ray microbeam. Cells in either G1 or S/G2 were irradiated selectively according to their colour in the same microscopic field. Time-lapse micrographs of the irradiated cells were acquired for 24 h after irradiation. For fluorescent immunostaining, phosphorylated histone proteins (γ-H2AX) indicated the induction of DNA double-strand breaks. The cell cycle was arrested by irradiation at S/G2. In contrast, cells irradiated at G1 progressed to S/G2. The foci were induced in cells irradiated at both G1 and S/G2, suggesting that the G1-S (or S) checkpoint pathway does not function in HeLa cells due to the fact that the cells are functionally p53 deficient, even though X-ray microbeam irradiation significantly induces double-strand breaks. These results demonstrate that single FUCCI cell exposure and live cell imaging are powerful methods for studying the effects of radiation on the cell cycle. (authors)

  1. Half body irradiation

    International Nuclear Information System (INIS)

    Bartelink, H.; Battermann, J.; Hart, G.

    1980-01-01

    Twenty-one patients with complaints of severe pain from disseminated breast cancer were treated with half body irradiation with a single dose of 600 to 800 rad. All of them had a relief of pain for periods ranging from 14 to 280 days, with a median duration of 101 days. The objective effects of a single radiation dose was studied in 15 patients with lung metastases. The growth delay observed in these patients was of the same order as the period of pain relief observed in breast cancer patients after half body irradiation. In general a longer lasting palliation was obtained in patients with slowly growing tumors

  2. Origin of a Raman scattering peak generated in single-walled carbon nanotubes by X-ray irradiation and subsequent thermal annealing

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Toshiya; Matsuda, Mitsuaki; Itoh, Chihiro, E-mail: citoh@sys.wakayama-u.ac.jp [Department of Materials Science, Wakayama University, 930 Sakaedani, Wakayama 640-8510 (Japan); Kisoda, Kenji [Department of Physics, Wakayama University, 930 Sakaedani, Wakayama 640-8510 (Japan)

    2016-08-15

    We have found that a Raman scattering (RS) peak around 1870 cm{sup −1} was produced by the annealing of the X-ray irradiated film of single-walled carbon nanotubes (SWNTs) at 450 {sup o}C. The intensity of 1870-cm{sup −1} peak showed a maximum at the probe energy of 2.3 eV for the RS spectroscopy with various probe lasers. Both the peak position and the probe-energy dependence were almost identical to those of the one-dimensional carbon chains previously reported in multi-walled carbon nanotubes. Consequently, we concluded that the 1870-cm{sup −1} peak found in the present study is attributed to carbon chains. The formation of carbon chains by the annealing at temperature lower than 500 {sup o}C is firstly reported by the present study. The carbon chains would be formed by aggregation of the interstitial carbons, which are formed as a counterpart of carbon vacancies by X-ray irradiation diffused on SWNT walls. The result indicates that the combination of X-ray irradiation and subsequent thermal annealing is a feasible tool for generating new nanostructures in SWNT.

  3. The radiosensitizing effect of Ku70/80 knockdown in MCF10A cells irradiated with X-rays and p(66)+Be(40) neutrons.

    Science.gov (United States)

    Vandersickel, Veerle; Mancini, Monica; Slabbert, Jacobus; Marras, Emanuela; Thierens, Hubert; Perletti, Gianpaolo; Vral, Anne

    2010-04-27

    A better understanding of the underlying mechanisms of DNA repair after low- and high-LET radiations represents a research priority aimed at improving the outcome of clinical radiotherapy. To date however, our knowledge regarding the importance of DNA DSB repair proteins and mechanisms in the response of human cells to high-LET radiation, is far from being complete. We investigated the radiosensitizing effect after interfering with the DNA repair capacity in a human mammary epithelial cell line (MCF10A) by lentiviral-mediated RNA interference (RNAi) of the Ku70 protein, a key-element of the nonhomologous end-joining (NHEJ) pathway. Following irradiation of control and Ku-deficient cell lines with either 6 MV X-rays or p(66)+Be(40) neutrons, cellular radiosensitivity testing was performed using a crystal violet cell proliferation assay. Chromosomal radiosensitivity was evaluated using the micronucleus (MN) assay. RNAi of Ku70 caused downregulation of both the Ku70 and the Ku80 proteins. This downregulation sensitized cells to both X-rays and neutrons. Comparable dose modifying factors (DMFs) for X-rays and neutrons of 1.62 and 1.52 respectively were obtained with the cell proliferation assay, which points to the similar involvement of the Ku heterodimer in the cellular response to both types of radiation beams. After using the MN assay to evaluate chromosomal radiosensitivity, the obtained DMFs for X-ray doses of 2 and 4 Gy were 2.95 and 2.66 respectively. After neutron irradiation, the DMFs for doses of 1 and 2 Gy were 3.36 and 2.82 respectively. The fact that DMFs are in the same range for X-rays and neutrons confirms a similar importance of the NHEJ pathway and the Ku heterodimer for repairing DNA damage induced by both X-rays and p(66)+Be(40) neutrons. Interfering with the NHEJ pathway enhanced the radiosensitivity of human MCF10A cells to low-LET X-rays and high-LET neutrons, pointing to the importance of the Ku heterodimer for repairing damage induced by both

  4. Body packers on your examination table: How helpful are plain x-ray images? A definitive low-dose CT protocol as a diagnosis tool for body packers.

    Science.gov (United States)

    Schulz, B; Grossbach, A; Gruber-Rouh, T; Zangos, S; Vogl, Th J; Eichler, K

    2014-12-01

    To analyze the clinical value and radiation dose of plain x-rays and CT in examining patients suspected of ingesting drug-filled packets. Thirty-eight patients with suspected internal concealment of drug-filled packets who were examined with plain x-rays or CT or both were included in the study. CT studies were performed using low-dose and standard-dose techniques. All radiographic images were analysed by two radiologists regarding identification of the packets and estimating the effective radiation dose from standard- and low-dose CT versus conventional x-ray examinations. Descriptive calculations were made regarding the number and density of packs and radiation dosage. The diagnostic performance of both radiologists with standard- and low-dose CT was calculated by analysing differences in the mean number of packs found. Thirty-one patients were positively identified as body packers with an average of 13 packs (min: n = 1, max: n = 58, total: n = 390); seven patients were not concealing drug packets. X-ray images were taken of 24 patients prior to CT, thus allowing a direct comparison between the two methods. The correct diagnosis was made in 42%, in 33% the radiologists were uncertain, and in 25% of drug packets were either not or wrongly identified. X-ray imaging had a positive predictive value of 20% with a negative predictive value of 81%. A total of 55 CT examinations were performed on all patients with a mean effective dose of 2 mSv (low dose) versus 9.3 mSv (standard dose). The visibility of packets on low-dose CT images compared to high-dose CT was not reduced: the radiologists identified 385 and 381 of the packets, respectively, with no difference regarding the examination technique (p = 0.24 and p = 0.253, respectively). The radiodensity of all drug-filled packets at CT ranged from 26-292 HU (mean 181.2 HU). X-ray imaging of supposed body packers leads to a significant risk of diagnostic errors and additional need for CT. Instead, a single abdominal low

  5. Fundamental Movement Skill Proficiency and Body Composition Measured by Dual Energy X-Ray Absorptiometry in Eight-Year-Old Children

    Science.gov (United States)

    Slotte, Sari; Sääkslahti, Arja; Metsämuuronen, Jari; Rintala, Pauli

    2015-01-01

    Objective: The main aim was to examine the association between fundamental movement skills (FMS) and objectively measured body composition using dual energy X-ray absorptiometry (DXA). Methods: A study of 304 eight-year-old children in Finland. FMS were assessed with the "Test of gross motor development," 2nd ed. Total body fat…

  6. Cosmic x ray physics

    Science.gov (United States)

    Mccammon, Dan; Cox, D. P.; Kraushaar, W. L.; Sanders, W. T.

    1991-01-01

    The annual progress report on Cosmic X Ray Physics for the period 1 Jan. to 31 Dec. 1990 is presented. Topics studied include: soft x ray background, new sounding rocket payload: x ray calorimeter, and theoretical studies.

  7. X-Ray

    Science.gov (United States)

    ... enema. What you can expect During the X-ray X-rays are performed at doctors' offices, dentists' offices, ... as those using a contrast medium. Your child's X-ray Restraints or other techniques may be used to ...

  8. Chest x-ray

    Science.gov (United States)

    Chest radiography; Serial chest x-ray; X-ray - chest ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  9. Abdominal x-ray

    Science.gov (United States)

    Abdominal film; X-ray - abdomen; Flat plate; KUB x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  10. Study and identification of paramagnetic centers by EPR technique in K3Cu(CN)4 crystals irradiated with X-rays

    International Nuclear Information System (INIS)

    Tancredo, A.

    1984-01-01

    Paramagnetic centers created in K 3 Cu(CN) 4 crystals by X-ray irradiation, using EPR technique are studied. The crystals are irradiated in following conditions: a) liquid nitrogen temperatures, b) room temperatures. Crystals field models of the paramagnetic centers which determine the following local symmetric in order to satisfy experimental results: a) Cu ++ in C sub(3v) symmetric and b) K 0 in distorted octahedral symmetry are proposed. The decay of these centers and the observation that Cu ++ ions are very much instable and disappear at T = 148K are studied. The K 0 atom remain up to T approximatelly 300K. (E.G.) [pt

  11. Anthropometrics and body composition by dual energy X-ray in children of obese women

    DEFF Research Database (Denmark)

    Tanvig, Mette; Vinter, Christina A; Jørgensen, Jan S

    2014-01-01

    OBJECTIVE: In obese women, 1) to assess whether lower gestational weight gain (GWG) during pregnancy in the lifestyle intervention group of a randomized controlled trial (RCT) resulted in differences in offspring anthropometrics and body composition, and 2) to compare offspring outcomes to a refe......OBJECTIVE: In obese women, 1) to assess whether lower gestational weight gain (GWG) during pregnancy in the lifestyle intervention group of a randomized controlled trial (RCT) resulted in differences in offspring anthropometrics and body composition, and 2) to compare offspring outcomes......-score (intervention group 0.06 [-0.17; 0.29] vs. controls -0.18 [-0.43; 0.05]), in the percentage of overweight or obese children (10.9% vs. 6.7%), in other anthropometrics, or in body composition values by DEXA. Outcomes between children from the RCT and the reference group children were not significantly different....... CONCLUSIONS: The RCT with lifestyle intervention in obese pregnant women did not result in any detectable effect on offspring anthropometrics or body composition by DEXA at 2.8 years of age. This may reflect the limited difference in GWG between intervention and control groups. Offspring of obese mothers from...

  12. Quantification of mouse in vivo whole-body vibration amplitude from motion-blur using x-ray imaging

    International Nuclear Information System (INIS)

    Hu, Zhengyi; Yuan, Xunhua; Pollmann, Steven I; Nikolov, Hristo N; Holdsworth, David W; Welch, Ian

    2015-01-01

    Musculoskeletal effects of whole-body vibration on animals and humans have become an intensely studied topic recently, due to the potential of applying this method as a non-pharmacological therapy for strengthening bones. It is relatively easy to quantify the transmission of whole-body mechanical vibration through the human skeletal system using accelerometers. However, this is not the case for small-animal pre-clinical studies because currently available accelerometers have a large mass, relative to the mass of the animals, which causes the accelerometers themselves to affect the way vibration is transmitted. Additionally, live animals do not typically remain motionless for long periods, unless they are anesthetized, and they are required to maintain a static standing posture during these studies. These challenges provide the motivation for the development of a method to quantify vibrational transmission in small animals. We present a novel imaging technique to quantify whole-body vibration transmission in small animals using 280 μm diameter tungsten carbide beads implanted into the hind limbs of mice. Employing time-exposure digital x-ray imaging, vibrational amplitude is quantified based on the blurring of the implanted beads caused by the vibrational motion. Our in vivo results have shown this technique is capable of measuring vibration amplitudes as small as 0.1 mm, with precision as small as  ±10 μm, allowing us to distinguish differences in the transmitted vibration at different locations on the hindlimbs of mice. (paper)

  13. Quantification of mouse in vivo whole-body vibration amplitude from motion-blur using x-ray imaging

    Science.gov (United States)

    Hu, Zhengyi; Welch, Ian; Yuan, Xunhua; Pollmann, Steven I.; Nikolov, Hristo N.; Holdsworth, David W.

    2015-08-01

    Musculoskeletal effects of whole-body vibration on animals and humans have become an intensely studied topic recently, due to the potential of applying this method as a non-pharmacological therapy for strengthening bones. It is relatively easy to quantify the transmission of whole-body mechanical vibration through the human skeletal system using accelerometers. However, this is not the case for small-animal pre-clinical studies because currently available accelerometers have a large mass, relative to the mass of the animals, which causes the accelerometers themselves to affect the way vibration is transmitted. Additionally, live animals do not typically remain motionless for long periods, unless they are anesthetized, and they are required to maintain a static standing posture during these studies. These challenges provide the motivation for the development of a method to quantify vibrational transmission in small animals. We present a novel imaging technique to quantify whole-body vibration transmission in small animals using 280 μm diameter tungsten carbide beads implanted into the hind limbs of mice. Employing time-exposure digital x-ray imaging, vibrational amplitude is quantified based on the blurring of the implanted beads caused by the vibrational motion. Our in vivo results have shown this technique is capable of measuring vibration amplitudes as small as 0.1 mm, with precision as small as  ±10 μm, allowing us to distinguish differences in the transmitted vibration at different locations on the hindlimbs of mice.

  14. Body composition in male elite athletes, comparison of bioelectrical impedance spectroscopy with dual energy X-ray absorptiometry

    Directory of Open Access Journals (Sweden)

    Klingberg Sofia

    2008-01-01

    Full Text Available Abstract Background The aim of this study was to compare body composition results from bioelectrical spectroscopy (BIS with results from dual energy X-ray absorptiometry (DXA in a population of male elite athletes. Body composition was assessed using DXA (Lunar Prodigy, GE Lunar Corp., Madison, USA and BIS (Hydra 4200, Xitron Technologies Inc, San Diego, California, USA at the same occasion. Agreement between methods was assessed using paired t-tests and agreement-plots. Results Thirty-three male elite athletes (soccer and ice hockey were included in the study. The results showed that BIS underestimates the proportion of fat mass by 4.6% points in the ice hockey players. In soccer players the BIS resulted in a lower mean fat mass by 1.1% points. Agreement between the methods at the individual level was highly variable. Conclusion Body composition results assessed by BIS in elite athletes should be interpreted with caution, especially in individual subjects. BIS may present values of fat mass that is either higher or lower than fat mass assessed by DXA, independent of true fat content of the individual.

  15. X-ray imaging system

    International Nuclear Information System (INIS)

    Houston, J.M.

    1980-01-01

    A novel, high-speed apparatus for use in X-ray computerised tomography is described in detail. It consists of a semi-circular array of X-ray sources, collimators and an ion chamber array for detection of the X-rays. The X-ray sources may be pulsed in salvos such that the corresponding detectors in the array are only illuminated by one source. The use of computer controlled salvos speeds up the image processing by at least a factor of two. The ion chamber array is designed to have a constant detection efficiency for varying angles of X-ray incidence. A detailed description of the detector construction and suggested gaseous fillings are given. It is claimed that the present tomographic system allows fast and accurate imaging of internal body organs and is insensitive to the blurring effects which motion of these organs tends to produce. (UK)

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... bone in the body, including the hand, wrist, arm, elbow, shoulder, spine, pelvis, hip, thigh, knee, leg ( ... x-ray tube is connected to a flexible arm that is extended over the patient while an ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... x-ray uses a very small dose of ionizing radiation to produce pictures of any bone in the ... of the body to a small dose of ionizing radiation to produce pictures of the inside of the ...

  18. Skin dose and response for the head and neck in patients irradiated with x-ray for tinea capitis: implications for environmental radioactivity

    International Nuclear Information System (INIS)

    Harley, N.H.; Kolber, A.B.; Shore, R.E.; Albert, R.E.; Altman, S.M.; Pasternack, B.S.

    1983-01-01

    The dose delivered to the skin of the head and neck in patients treated with x-ray irradiation for childhood tinea capitis was reconstructed. This was possible by utilizing a phantom made from the skull of a seven year old child and irradiating it with the same technique and x-ray machine used in tinea capitis therapy two to four decades ago. Seventy-eight basal cell carcinomas (BCC) have appeared so far in 40 of 1727 irradiated white children and none in 500 irradiated black children. The dose distribution over the face and scalp is used to estimate the risk of BCC per person per rad. These results must be considered preliminary due to the relatively young age of the irradiated group (<50 years) at the present time. From the decreased risk per rad for the portion of the scalp that is hair covered, it appears that environmental ultraviolet radiation may play a key role in the expression of BCC. A cumulative hazard plot is utilized to tentatively extend the data to lifetime risk of 0.003 per rad with an upper limit of 0.006 per rad. Environmental radiation dose to the skin possibly account for 20% of observed BCC if this tentative risk estimate is valid

  19. X-ray astronomy

    International Nuclear Information System (INIS)

    Giacconi, R.; Gursky, H.

    1974-01-01

    This text contains ten chapters and three appendices. Following an introduction, chapters two through five deal with observational techniques, mechanisms for the production of x rays in a cosmic setting, the x-ray sky and solar x-ray emission. Chapters six through ten include compact x-ray sources, supernova remnants, the interstellar medium, extragalactic x-ray sources and the cosmic x-ray background. Interactions of x rays with matter, units and conversion factors and a catalog of x-ray sources comprise the three appendices. (U.S.)

  20. [Which alternative method to dual-energy X-ray absorptiometry for assessing body composition in overweight and obese adolescents?].

    Science.gov (United States)

    Lazzer, S; Boirie, Y; Meyer, M; Vermorel, M

    2005-07-01

    Professionals in charge of overweight and obese children and adolescents need a simple, reliable and precise method for assessing body composition. To compare body composition as assessed by dual-energy X-ray absorptiometry (DXA), bioelectrical impedance analysis (BIA) and the skinfold thickness (SFT) method in overweight and obese adolescents, and to establish and validate new predictive equations of body composition from BIA measurements using DXA as standard method. Body composition was assessed in 143 obese adolescents (Z-score = 3.2 +/- 1.4) aged 12 to 17 years by DXA, BIA (RJL System, Analycor and Analycor XF models) and SFT (Siri and Slaughter's equations). New prediction equations of fat mass (FM) as assessed by DXA were computed from BIA measurements in a calibration group, and validated in an homologous group of subjects. Results. - The Bland-Altman test showed that compared to DXA, BIA underestimated FM by 2.8 +/- 2.0 kg and 2.3 +/- 2.1 kg using the RJL System and Analycor impedancemeter, respectively (P Siri's equation underestimated FM by 4.0 +/- 2.9 kg (P < 0.001). The alternative to the DXA method to assess FM was BIA with new prediction equations including gender, body weight, height(2)/resistance and reactance. DXA, BIA and the SFT method were not directly interchangeable. The SFT method was inadequate to assess body composition in overweight and obese adolescents. BIA and new prediction equations could be an alternative to the DXA method in overweight and obese adolescents.

  1. Precision Error in Dual-Energy X-Ray Absorptiometry Body Composition Measurements in Elite Male Rugby League Players.

    Science.gov (United States)

    Barlow, Matthew J; Oldroyd, Brian; Smith, Debbie; Lees, Matthew J; Brightmore, Amy; Till, Kevin; Jones, Benjamin; Hind, Karen

    2015-01-01

    Body composition analysis using dual-energy X-ray absorptiometry (DXA) is becoming increasingly popular in both clinical and sports science settings. Obesity, characterized by high fat mass (FM), is associated with larger precision errors; however, precision error for athletic groups with high levels of lean mass (LM) are unclear. Total (TB) and regional (limbs and trunk) body composition were determined from 2 consecutive total body scans (GE Lunar iDXA) with re-positioning in 45 elite male rugby league players (age: 21.8 ± 5.4 yr; body mass index: 27.8 ± 2.5 kg m(-1)). The root mean squared standard deviation (percentage co-efficient of variation) were TB bone mineral content: 24g (1.7%), TB LM: 321 g (1.6%), and TB FM: 280 g (2.3%). Regional precision values were superior for measurements of bone mineral content: 4.7-16.3 g (1.7-2.1%) and LM: 137-402 g (2.0-2.4%), than for FM: 63-299 g (3.1-4.1%). Precision error of DXA body composition measurements in elite male rugby players is higher than those reported elsewhere for normal adult populations and similar to those reported in those who are obese. It is advised that caution is applied when interpreting longitudinal DXA-derived body composition measurements in male rugby players and population-specific least significant change should be adopted. Copyright © 2015 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  2. High K-alpha X-ray Conversion Efficiency From Extended Source Gas Jet Targets Irradiated by Ultra Short Laser Pulses

    Energy Technology Data Exchange (ETDEWEB)

    Kugland, N L; Constantin, C; Collette, A; Dewald, E; Froula, D; Glenzer, S H; Kritcher, A; Neumayer, P; Ross, J S; Niemann, C

    2007-11-01

    The absolute laser conversion efficiency to K{sub {alpha}}-like inner shell x-rays (integrated from K{sub {alpha}} to K{sub {beta}}) is observed to be an order of magnitude higher in argon gas jets than in solid targets due to enhanced emission from higher ionization stages following ultra short pulse laser irradiation. Excluding the higher ionization stages, the conversion efficiency to near-cold K{sub {alpha}} is the same in gas jets as in solid targets. These results demonstrate that gas jet targets are bright, high conversion efficiency, high repetition rate, debris-free multi-keV x-ray sources for spectrally resolved scattering and backlighting of rapidly evolving dense matter.

  3. Effect of X-ray Irradiation on the Male Moths of Two Tropical Races of the Silkworm and Inheritance of Induced Sterility in the Progenies

    Directory of Open Access Journals (Sweden)

    G. Subramanya

    2010-01-01

    Full Text Available Newly emerged male moths of silkworm Bombyx mori were treated with in 24 h of eclosion irradiated with two independent doses of 50 Gy and 100 Gy X-rays. The effects of X-rays in the parental generation have indicated significant increase of unfertilized and unhatched eggs followed by significant reduction in the hatchability in the treated batches compared to control. The inheritance of induced sterility was examined in the succeeding generations by rearing the F 1 , F 2 and F 3 silkworm progenies and by crossing the progenies of treated males with untreated female moths. It is evident from the results that the number of hatched eggs gradually increased from F 1 –F 3 generations. Thus, the results showed that the egg hatchability do not remain constant at every generation and hatching tendency of eggs increase in the progenies of treated batches. The mechanism of inherited sterility was discussed.

  4. Kinetic Boltzmann approach adapted for modeling highly ionized matter created by x-ray irradiation of a solid

    Czech Academy of Sciences Publication Activity Database

    Ziaja, B.; Saxena, V.; Son, S.-K.; Medvedev, N.; Barbrel, B.; Woloncewicz, B.; Stránský, Michal

    2016-01-01

    Roč. 93, č. 5 (2016), 1-6, č. článku 053210. ISSN 2470-0045 R&D Projects: GA MŠk(CZ) LG13029 Institutional support: RVO:68378271 Keywords : X-ray * Boltzmann equation Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.366, year: 2016

  5. A setup to perform X-ray irradiation tests on scintillating fibres for the SciFi project

    CERN Document Server

    Gavardi, Laura; Joram, Christian; Kristic, Robert

    2017-01-01

    An X-ray setup has been installed at CERN. The setup will serve for quality assurance purposes related to the acceptance of $11'000~ \\text{km}$ of scintillating plastic fibres for the SciFi detector of LHCb. The X-ray tube has a tungsten target and can be powered up to 60kV, 30mA. The setup is intended to monitor the relative radiation response of the different fibre batches. The dose rate absorbed by the fibre under test can be tuned, adjusting the settings of the X-ray tube and adding aluminium filters of different thicknesses. When operating the X-ray tube without filters at a high voltage of $40\\rm \\,kV$ and an anode current of $30\\rm \\,mA$, the dose rate is about $23\\rm \\,Gy/min$. The maximum dose of about $35\\rm \\,kGy$ expected in the SciFi Tracker can be thus reached in about $1\\rm \\,day$.

  6. Far-ultraviolet and X-ray irradiated protoplanetary disks: a grid of models : I. The disk structure

    NARCIS (Netherlands)

    Meijerink, R.; Aresu, G.; Kamp, I.; Spaans, M.; Thi, W. -F; Woitke, P.

    2012-01-01

    Context. Planets are thought to eventually form from the mostly gaseous (~99% of the mass) disks around young stars. The density structure and chemical composition of protoplanetary disks are affected by the incident radiation field at optical, far-ultraviolet (FUV), and X-ray wavelengths, as well

  7. Far-ultraviolet and X-ray irradiated protoplanetary disks : a grid of models I. The disk structure

    NARCIS (Netherlands)

    Meijerink, R.; Aresu, G.; Kamp, I.; Spaans, M.; Thi, W. -F.; Woitke, P.

    2012-01-01

    Context. Planets are thought to eventually form from the mostly gaseous (similar to 99% of the mass) disks around young stars. The density structure and chemical composition of protoplanetary disks are affected by the incident radiation field at optical, far-ultraviolet (FUV), and X-ray wavelengths,

  8. Far-ultraviolet and X-ray irradiated protoplanetary disks: a grid of models. I. The disk structure

    NARCIS (Netherlands)

    Meijerink, R.; Aresu, G.; Kamp, I.; Spaans, M.; Thi, W.-F.; Woitke, P.

    2012-01-01

    Context. Planets are thought to eventually form from the mostly gaseous (~99% of the mass) disks around young stars. The density structure and chemical composition of protoplanetary disks are affected by the incident radiation field at optical, far-ultraviolet (FUV), and X-ray wavelengths, as well

  9. Far-ultraviolet and X-ray irradiated protoplanetary disks: a grid of models. II. Gas diagnostic line emission

    NARCIS (Netherlands)

    Aresu, G.; Meijerink, R.; Kamp, I.; Spaans, M.; Thi, W.-F.; Woitke, P.

    2012-01-01

    Context. Most of the mass in protoplanetary disks is in the form of gas. The study of the gas and its diagnostics is of fundamental importance in order to achieve a detailed description of the thermal and chemical structure of the disk. Both radiation from the central star (from optical to X-ray

  10. Far-ultraviolet and X-ray irradiated protoplanetary disks : a grid of models II. Gas diagnostic line emission

    NARCIS (Netherlands)

    Aresu, G.; Meijerink, R.; Kamp, I.; Spaans, M.; Thi, W. -F.; Woitke, P.

    2012-01-01

    Context. Most of the mass in protoplanetary disks is in the form of gas. The study of the gas and its diagnostics is of fundamental importance in order to achieve a detailed description of the thermal and chemical structure of the disk. Both radiation from the central star (from optical to X-ray

  11. Far-ultraviolet and X-ray irradiated protoplanetary disks: a grid of models : II. Gas diagnostic line emission

    NARCIS (Netherlands)

    Aresu, G.; Meijerink, R.; Kamp, I.; Spaans, M.; Thi, W. -F; Woitke, P.

    2012-01-01

    Context. Most of the mass in protoplanetary disks is in the form of gas. The study of the gas and its diagnostics is of fundamental importance in order to achieve a detailed description of the thermal and chemical structure of the disk. Both radiation from the central star (from optical to X-ray

  12. Whole body X-ray CT scanner SCT-3000T series

    International Nuclear Information System (INIS)

    Saida, Teruhiko; Takemura, Kunihiko; Suzuki, Satoru; Sato, Yukio; Kawamoto, Yasushi; Goto, Mitsuhiro; Mishina, Yukio

    1989-01-01

    The whole body CT scanner, SCT-3000T series which improve the patient through-put and the diagnostic capability, has been developed. In the SCT-3000T series CT scanners, the great reduction of the reconstruction time and the scan cycle time has been achieved by developing the special purpose hardwares for image reconstruction such as the fast front end processor, the intelligent buffer memory. In case of the SCT-3000TX routine conditions of operation, including 3.0 sec scan, table increment, image reconstruction and image filing, the scan cycle time is about 9 seconds which is the shortest value among the competitive models. Furthermore, the higher diagnostic capability has been provided with the system, by adopting the 1024 x 1024 display matrices, and by developing the diagnostic softwares such as 3-D display program, arbitrary curved plane MPR program, r-CBF measurement program and etc. (author)

  13. Personal experience with whole-body, low-dosage, digital X-ray scanning (LODOX-Statscan in trauma

    Directory of Open Access Journals (Sweden)

    Zimmermann Heinz

    2009-09-01

    Full Text Available Abstract Background Lodox-Statscan is a whole-body, skeletal and soft-tissue, low-dose X-ray scanner Anterior-posterior and lateral thoraco-abdominal studies are obtained in 3-5 minutes with only about one-third of the radiation required for conventional radiography. Since its approval by the Food and Drug Administration (FDA in the USA, several trauma centers have incorporated this technology into their Advanced Trauma Life Support protocols. This review provides a brief overview of the system, and describes the authors' own experience with the system. Methods We performed a PubMed search to retrieve all references with 'Lodox' and 'Stat-scan' used as search terms. We furthermore used the google search engine to identify existing alternatives. To the best of our knowledge, this is the only FDA-approved device of its kind currently used in trauma. Results and Conclusion The intention of our review has been to sensitize the readership that such alternative devices exist. The key message is that low dosage full body radiography may be an alternative to conventional resuscitation room radiography which is usually a prelude to CT scanning (ATLS algorithm. The combination of both is radiation intensive and therefore we consider any reduction of radiation a success. But only the future will show whether LS will survive in the face of low-dose radiation CT scanners and magnetic resonance imaging devices that may eventually completely replace conventional radiography.

  14. Precision of total and regional body fat estimates from dual-energy X-ray absorptiometer measurements.

    Science.gov (United States)

    Kaminsky, L A; Ozemek, C; Williams, K L; Byun, W

    2014-01-01

    To evaluate the precision of both total %fat and all the regional %fat measures acquired from both the Lunar Prodigy and Lunar iDXA software. Cross-sectional study. University-based research laboratory. The sample consisted of 300 individual test records from men and women who had volunteered to participate in dual-energy x-ray absorptiometer (DXA) technician precision training studies. Subjects ranged in age from 20-84 years and in body mass index from 15.7-52.0 kg.m-2. A total of 27 different technicians performed three total body scan measurements on 10-15 different subjects. The Lunar Prodigy and Lunar iDXA were used for 253 and 47 precision training evaluations, respectively. The regions of interest (ROI) were automatically determined by the enCORE software (autoROI) for total body, android, gynoid, trunk, legs, and arms regions and the region %fat data were used for analyses. The CV for total body %fat was 1.9% and 0.9% for the Prodigy and iDXA, respectively. CV's for %fat measures at regional sites ranged from 1.2-4.4% for the Prodigy measures and 0.9-2.4% for the iDXA measures. The ICC for both devices ranged from 0.990 to 0.999. Monitoring the status of body composition changes with age is gaining more clinical acceptance. Thus, it is important that practitioners use measures that are both precise and accurate. The findings from the current study add support that DXA measurements can be used with a high level of confidence for serial testing of patients.

  15. Protective effects of the fermented milk Kefir on X-ray irradiation-induced intestinal damage in B6C3F1 mice.

    Science.gov (United States)

    Teruya, Kiichiro; Myojin-Maekawa, Yuki; Shimamoto, Fumio; Watanabe, Hiromitsu; Nakamichi, Noboru; Tokumaru, Koichiro; Tokumaru, Sennosuke; Shirahata, Sanetaka

    2013-01-01

    Gastrointestinal damage associated with radiation therapy is currently an inevitable outcome. The protective effect of Kefir was assessed for its usefulness against radiation-induced gastrointestinal damage. A Kefir supernatant was diluted by 2- or 10-fold and administered for 1 week prior to 8 Gray (Gy) X-ray irradiation at a dose rate of 2 Gy/min, with an additional 15 d of administration post-irradiation. The survival rate of control mice with normal drinking water dropped to 70% on days 4 through 9 post-irradiation. On the other hand, 100% of mice in the 10- and 2-fold-diluted Kefir groups survived up to day 9 post-irradiation (pKefir solutions (pKefir solutions protected the crypts from radiation, and promoted crypt regeneration. In addition, lyophilized Kefir powder was found to significantly recover the testis weights (pKefir could be a promising candidate as a radiation-protective agent.

  16. Effects of low dose X-ray irradiation on antigen presentation and IL-12 secretion in human dendritic cells in vitro

    International Nuclear Information System (INIS)

    Yan Peng; Jiang Qisheng; Li Fengsheng; He Rui; Wang Cuilan; Li Xiao

    2012-01-01

    Objective: To explore the effects of low dose X-ray irradiation on the ability of antigen presentation and IL-12 secretion in human dendritic cells that had been cultured for different time in vitro. Methods: The human peripheral blood mononuclear cells (PBMC) were collected and differentiated to dendritic cells (DCs) by rhGM-CSF and rhIL-4 treatment in vitro. The DCs were divided into 3 groups, group A: DCs were cultured for 2 d and then irradiated with 0.05, 0.1, 0.2 and 0.5 Gy X-rays; group B: DCs were cultured for 6 d and then irradiated as above; group C:DCs were cultured without irradiation.At 8 d of cell culture, the DCs were applied to activate T cells and CCK-8 was used to detect MLR (mixed lymphocyte reaction), and the antigen presentation ability of DCs was evaluated. MTT assay was also used to test the cell-killing effect of the activated T-cells on A549 cells. IL-12 in the culture medium of DCs was detected by ELISA. Results: After irradiation with 0.2 and 0.5 Gy X-rays, the antigen presentation ability of DCs was decreased in group A (t=2.79 and 3.71, P<0.05), but significantly increased in group B (t=3.60 and 3.11, P<0.05). The ability of the T cell activation was detected and the proliferation of A549 cells was slightly inhibited by the DCs in group A (t=2.89 and 2.91, P<0.05), but was obviously inhibited by the DCs in group B (t=2.91 and 2.82, P<0.05). Meanwhile,the level of IL-12 was dramatically decreased in group A (t=4.44 and 6.93, P<0.05), but was increased in group B (t=3.51 and 4.12, P<0.05). Conclusions: The abilities of antigen presentation and proliferation inhibition of DCs could be down-regulated by low dose (<0.5 Gy) of X-ray irradiation at the early stage of DCs, but was up-regulated at the late stage of DCs culture. (authors)

  17. X-ray microtomography

    International Nuclear Information System (INIS)

    Dunsmuir, J.H.; Ferguson, S.R.; D'Amico, K.L.; Stokes, J.P.

    1991-01-01

    In this paper the authors describe the application of a new high-resolution X-ray tomographic microscope to the study of porous media. The microscope was designed to exploit the properties of a synchrotron X-ray source to perform three dimensional tomography on millimeter sized objects with micron resolution and has been used in materials science studies with both synchrotron and conventional and synchrotron sources will be compared. In this work the authors have applied the microscope to measure the three dimensional structure of fused bead packs and berea sandstones with micron resolution and have performed preliminary studies of flow in these media with the microscope operated in a digital subtraction radiography mode. Computer graphics techniques have been applied to the data to visually display the structure of the pore body system. Tomographic imaging after flow experiments should detect the structure of the oil-water interface in the pore network and this work is ongoing

  18. Precision of dual energy X-ray absorptiometry for body composition measurements in cats

    International Nuclear Information System (INIS)

    Borges, N.C.; Vasconcellos, R.S.; Canola, J.C.; Carciofi, A.C.; Pereira, G.T.; Paula, F.J.A.

    2008-01-01

    A short-term precision error of the individual subject and the DEXA technique, such as the effect of the repositioning of the cat on the examination table, were established. Four neutered adult cats (BW=4342 g) and three females (BW=3459 g) were submitted to five repeated scans with and without repositioning between them. Precision was estimated from the mean of the five measurements and expressed by the individual coefficient of variation (CV). The precision error of the technique was estimated by the variance of scan pool (n=35) and expressed in CV for the technique (CVt). The degrees of freedom and confidence intervals were determined to avoid underestimation of precision errors. Bone mineral content (BMC), lean mass (LM), and fat mass (FM) averages were higher (P<0.05) when animals were repositioned. The CVt was significantly higher (P<0.05) for bone mineral density (BMD), LM, and FM when the animals were repositioned. For short-term precision measurements, the repositioning of the animal was important to establish the precision of the technique. The dual energy xray absorptiometry method provided precision for body composition measurements in adult cats. (author)

  19. Influence of different iodinated contrast media on the induction of DNA double-strand breaks after in vitro X-ray irradiation.

    Science.gov (United States)

    Deinzer, Christoph K W; Danova, Daniela; Kleb, Beate; Klose, Klaus J; Heverhagen, Johannes T

    2014-01-01

    The objective of this work was to examine differences in DNA double-strand break induction in peripheral blood lymphocytes after in vitro X-ray irradiation between iodinated contrast agents. Four different iodinated X-ray contrast agents--three of them with two different iodine concentrations--and mannitol (negative control; concentration of 150 mg mannitol per ml blood) were pipetted into blood samples so that there was a concentration of 0, 7.5 or 15 mg of iodine per ml blood in the samples. Negative controls without contrast medium (0 mg of iodine per ml blood) were also processed for every irradiation dose. The tubes were exposed to 0, 20 or 500 mGy in vitro X-ray irradiation. After that, the lymphocytes were separated by using density-gradient centrifugation. Fluorescence microscopy was applied to determine the average number of γH2AX-foci per lymphocyte in the presence or absence of different contrast media or mannitol. Differences in the number of γH2AX-foci were statistically analysed by one-way ANOVA and post-hoc Tukey's honestly significant difference test. Iodinated contrast agents led to a statistically significant increase in DNA double-strand breaks after in vitro irradiation. This effect increased statistically significant with rising radiation dose and appeared independent of the contrast agent used (iopromid, iodixanol, iomeprol, iopamidol). A statistically significant difference in DNA damage between the different tested contrast agents was not found. Therefore, the increase in DNA double-strand breaks depends solely on the amount of iodine applied. For evaluation of clinical consequences, our findings could be tested in further animal studies. Copyright © 2014 John Wiley & Sons, Ltd.

  20. Greater body mass independently predicts less radiographic progression on X-ray and MRI over 1-2 years

    DEFF Research Database (Denmark)

    Baker, Joshua F; Østergaard, Mikkel; George, Michael

    2014-01-01

    INTRODUCTION: Greater body mass index (BMI) has been associated with less radiographic progression in rheumatoid arthritis (RA). We evaluated the association between BMI and joint damage progression as measured by X-ray and MRI. METHODS: 1068 subjects with RA from two clinical trials of golimumab...

  1. Body composition and bone mineral mass in normal and obese female population using dual X-ray absorptiometry

    International Nuclear Information System (INIS)

    Massardo, T.; Gonzalez, P.; Coll, C.; Rodriguez, J.L.; Solis, I.; Oviedo, S.

    2002-01-01

    It has been observed that a greater percentage of body fat is associated with augmented bone mineral mass. Objective: The goal of this work was to assess the relationship between bone mineral density (BMD in g/cm 2 ) and content (BMC in g) and soft tissue components, fat and lean mass (in g) in whole body of adult female population in Chile. Method: We studied 185 volunteers, asymptomatic, excluding those using estrogens, regular medication, tobacco (>10 cigarettes/day), excessive alcohol intake or with prior oophorectomy. They were separated in 111 pre and 74 post menopausal and according to body mass index (BMI) they were 37 women > 30 kg/m 2 and 148 2 . A Lunar Dual X-Ray absorptiometer was used to determine whole BMD and BMC. Results: Post menopausal women were older and smaller [p:0.0001], with higher body mass index [p:0.0007] and with lower BMD and BMC and higher fat mass than the pre menopausal group; In the whole group, women with BMI ≥ 30 (obese) were compared with normal weight observing no difference in BMD. The fat mass incremented significantly with age. Obese women > 50 years presented greater BMC than the non-obese. The percentage of fat corresponded to 48% in the obese group and to 39% in the non-obese [p<0.0001]. Conclusion: Fat mass somehow protect bone mineral loss in older normal population, probably associated to multifactorial causes including extra ovaric estrogen production. Postmenopausal women presented lower mineral content than premenopausal, as it was expected

  2. Chest X-Ray

    Medline Plus

    Full Text Available ... about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed x-ray exams and use a very small dose of ... of the inside of the chest. A chest x-ray is used to evaluate the lungs, heart and ...

  3. In vitro co-culture experiments on prostate cancer and small intestine cells irradiated with carbon ions and x-rays

    International Nuclear Information System (INIS)

    Neubeck, C. von; Weyrather, W.-K.; Durante, M.

    2009-01-01

    Intensity modulated radiotherapy (IMRT) delivers the dose in many small irradiation fields of different beam direction to achieve a 3 dimensional tumour conformal dose overlapping with a maximum of normal tissue protection. In 2006 a study was started at GSI to treat prostate cancer patients with a boost irradiation of carbon ions in combination with an IMRT treatment administered at the Uniklinikum Heidelberg. The carbon ions are delivered in two opposing fields. So IMRT irradiation includes more normal tissue than carbon ion treatment but even here parts of the rectum and the bladder are in the irradiated field. This raises the question whether the irradiated tumor cells influence the normal cells (irradiated/ unirradiated) but also whether the normal irradiated cells influences normal tissue in a different way for carbon and photon irradiation. To study this problem, we established an in vitro co-culture model of prostate cancer and small intestine cells of the rat to simulate the patient treatment situation for analyzing tissue reaction exemplary. For characterization of the cells lines the parameters alpha and beta (linear quadratic model) for clonogenic survival were determined for x-rays and for carbon ions of different energies. For co-culture experiments unirradiated and irradiated cells were seeded together and the survival was analyzed

  4. X-ray sky

    International Nuclear Information System (INIS)

    Gruen, M.; Koubsky, P.

    1977-01-01

    The history is described of the discoveries of X-ray sources in the sky. The individual X-ray detectors are described in more detail, i.e., gas counters, scintillation detectors, semiconductor detectors, and the principles of X-ray spectrometry and of radiation collimation aimed at increased resolution are discussed. Currently, over 200 celestial X-ray sources are known. Some were identified as nebulae, in some pulsations were found or the source was identified as a binary star. X-ray bursts of novae were also observed. The X-ray radiation is briefly mentioned of spherical star clusters and of extragalactic X-ray sources. (Oy)

  5. Assessment of Body Composition Using Dual Energy X-Ray Absorptiometry in Patients with Liver Cirrhosis: Comparison with Anthropometry

    Science.gov (United States)

    Jeong, Seong Han; Lee, Jeong A; Kim, Jin A; Lee, Mun Woo; Chae, Hee Bok; Choi, Won Jun; Shin, Hyoung Shik; Lee, Ki Hyeong; Youn, Sei Jin; Koong, Sung Soo; Park, Seon Mee

    1999-01-01

    Objectives The aim of this study was to evaluate changes of body composition in cirrhotic patients. Dual energy x-ray absorptiometry (DEXA) and anthropometry were used, and the values obtained were compared. Methods Mid-arm fat and muscle areas were calculated by anthropometry in 66 cirrhotic patients and 94 healthy controls. In 37 of the cirrhotic patients and 39 of the controls, fat mass, lean soft tissue mass and bone mineral contents were measured with DEXA. Results The number of cirrhotic patients with measured values below the fifth percentile of normal controls was 21 (31.8%) by mid-arm fat area, six (9.1%) by mid-arm muscle area, 15 (40.5%) by fat mass and 0 (0%) by lean soft tissue mass. The fat mass in cirrhotic patients was less than in controls, whereas lean soft tissue mass and bone mineral content were not different. Fat depletion was severe in Child-class C patients and with severe ascites. Mid-arm fat area and fat mass showed close correlation (r = 0.85, p<0.01), but mid-arm muscle area and lean soft tissue mass showed poor correlation (r = 0.32, p<0.05). Conclusion Cirrhotic patients showed lower fat component, with preserved lean soft tissue mass and bone mineral content. In clinical practice, the measurement of mid-arm fat area was useful for the assessment of fat mass. PMID:10461427

  6. Lean body mass assessment based on UV absorbance in spent dialysate and dual-energy x-ray absorptiometry.

    Science.gov (United States)

    Tomson, Ruth; Fridolin, Ivo; Luman, Merike

    2015-06-01

    The aim of the study was to explore the possibility of assessing lean body mass (LBM) based on UV absorbance measurements in spent dialysate. 9 patients on chronic three-times-a-week HD (4 female, 5 male, mean age 58.8 ± 8.6 years) were studied. Blood and spent dialysate samples were collected for 3 consecutive hemodialysis (HD) sessions from every patient. A double-beam spectrophotometer was used for the determination of UV absorbance in the collected spent dialysate samples. Dual-energy x-ray absorptiometry (DXA) scans were performed on an interdialytic day. LBM was calculated based on creatinine concentration in blood (LBMblood) and UV absorbance in spent dialysate (LBMa) and assessed by DXA (LBMDXA). Also, in vitro experiments were carried out to investigate the effect of tissue hydration on DXA measurements. Although LBMa was slightly lower compared to LBMblood, the estimates based on UV absorbance in spent dialysate presented greater accuracy and precision compared to LBMDXA. The significant difference between LBMblood and LBMDXA was with high probability caused by the altered tissue hydration of HD patents. In summary, the results show that it is possible to asses LBM based on UV absorbance in spent dialysate.

  7. Measuring body composition in dogs using multifrequency bioelectrical impedance analysis and dual energy X-ray absorptiometry.

    Science.gov (United States)

    Rae, L S; Vankan, D M; Rand, J S; Flickinger, E A; Ward, L C

    2016-06-01

    Thirty-five healthy, neutered, mixed breed dogs were used to determine the ability of multifrequency bioelectrical impedance analysis (MFBIA) to predict accurately fat-free mass (FFM) in dogs using dual energy X-ray absorptiometry (DXA)-measured FFM as reference. A second aim was to compare MFBIA predictions with morphometric predictions. MFBIA-based predictors provided an accurate measure of FFM, within 1.5% when compared to DXA-derived FFM, in normal weight dogs. FFM estimates were most highly correlated with DXA-measured FFM when the prediction equation included resistance quotient, bodyweight, and body condition score. At the population level, the inclusion of impedance as a predictor variable did not add substantially to the predictive power achieved with morphometric variables alone; in individual dogs, impedance predictors were more valuable than morphometric predictors. These results indicate that, following further validation, MFBIA could provide a useful tool in clinical practice to objectively measure FFM in canine patients and help improve compliance with prevention and treatment programs for obesity in dogs. Copyright © 2016. Published by Elsevier Ltd.

  8. Observation of K-shell soft X ray emission of nitrogen irradiated by XUV-free electron laser FLASH at intensities greater than 1016 W/cm2

    International Nuclear Information System (INIS)

    Galtier, E.; Rosmej, F.B.; Galtier, E.; Rosmej, F.B.; Renner, O.; Juha, L.; Chalupsky, J.; Gauthier, J.C.; White, S.; Riley, D.; Vinko, S.; Witcher, T.; Wark, J.; Nagler, B.; Lee, R.W.; Nelson, A.J.; Toleikis, S.

    2011-01-01

    In the past few years, the development of light sources of the 4. generation, namely XUV/X-ray Free Electron Lasers provides to the scientific community outstanding tools to investigate matter under extreme conditions never obtained in laboratories so far. As theory is at its infancy, the analysis of matter via the self-emission of the target is of central importance. The characterization of such dense matter is possible if photons can escape the medium. As the absorption of K-shell X-ray transitions is minimal, it plays a key role in this study. We report here the first successful observation of K-shell emission of Nitrogen at 430 eV using an XUV-Free Electron Laser to irradiate solid Boron Nitride targets under exceptional conditions: photon energy of 92 eV, pulse duration of similar to 20 fs, micro focusing leading to intensities larger than 10 16 W/cm 2 . Using a Bragg crystal of THM coupled to a CCD, we resolved K-shell line emission from different charge states. We demonstrate that the spectroscopic data allow characterization of electron heating processes when X-ray radiation is interacting with solid matter. As energy transport is non-trivial because the light source is monochromatic, these results have an important impact on the theory. (authors)

  9. Assessment of EchoMRI-AH versus dual-energy X-ray absorptiometry to measure human body composition.

    Science.gov (United States)

    Galgani, J E; Smith, S R; Ravussin, E

    2011-09-01

    The sensitivity to detect small changes in body composition (fat mass and fat-free mass) largely depends on the precision of the instrument. We compared EchoMRI-AH and dual-energy X-ray absorptiometry (DXA) (Hologic QDR-4500A) for estimating fat mass in 301 volunteers. Body composition was evaluated in 136 males and 165 females with a large range of body mass index (BMI) (19-49 kg m(-2)) and age (19-91 years old) using DXA and EchoMRI-AH. In a subsample of 13 lean (BMI=19-25 kg m(-2)) and 21 overweight/obese (BMI>25 kg m(-2)) individuals, within-subject precision was evaluated from repeated measurements taken within 1 h (n=3) and 1 week apart (mean of three measurements taken on each day). Using Bland-Altman analysis, we compared the mean of the fat mass measurements versus the difference in fat mass measured by both instruments. We found that EchoMRI-AH quantified larger amount of fat versus DXA in non-obese (BMI<30 kg m(-2) (1.1 kg, 95% confidence interval (CI(95)):-3.7 to 6.0)) and obese (BMI ≥ 30 kg m(-2) (4.2 kg, CI(95):-1.4 to 9.8)) participants. Within-subject precision (coefficient of variation, %) in fat mass measured within 1 h was remarkably better when measured by EchoMRI-AH than DXA (<0.5 versus <1.5%, respectively; P<0.001). However, 1-week apart within-subject variability showed similar values for both instruments (<2.2%; P=0.15). EchoMRI-AH yielded greater fat mass values when compared with DXA (Hologic QDR-4500A), particularly in fatter subjects. EchoMRI-AH and DXA showed similar 1-week apart precision when fat mass was measured both in lean and overweight/obese individuals.

  10. Influence of irradiation conditions on polytetrafluoroethylen ablation induced by soft x-rays emitted from laser-produced plasma

    Czech Academy of Sciences Publication Activity Database

    Viskup, Richard; Juha, Libor; Krása, Josef

    2004-01-01

    Roč. 54, č. 3 (2004), s. 277-284 ISSN 0323-0465 R&D Projects: GA MŠk LA 055; GA MŠk 1P04LA235; GA MŠk LN00A100 Institutional research plan: CEZ:AV0Z1010921 Keywords : ablation * X-rays Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.513, year: 2004

  11. Antiproliferative effects of ZnO, ZnO-MTCP, and ZnO-CuMTCP nanoparticles with safe intensity UV and X-ray irradiation.

    Science.gov (United States)

    Sadjadpour, Susan; Safarian, Shahrokh; Zargar, Seyed Jalal; Sheibani, Nader

    2016-01-01

    In photodynamic therapy (PDT) of cancer both the light and the photosensitizing agent are normally harmless, but in combination they could result in selective tumor killing. Zinc oxide nanoparticles were synthesized and coated with the amino acid cysteine to provide an adequate arm for conjugation with porphyrin photosensitizers (meso-tetra (4-carboxyphenyl) porphyrin [MTCP] and CuMTCP). Porphyrin-conjugated nanoparticles were characterized by TEM, FTIR, and UV-vis, and fluorescence spectrophotometry. The 3-[4, 5-dimethylthiazol-2-yl]-2,5-diphenyl tetrazolium bromide (MTT) assay was used to measure cell viability in the presence or absence of porphyrin conjugates following UV and X-ray irradiation. The uptake of the porphyrin-conjugated ZnO nanoparticles by cells was detected using fluorescence microscopy. Our results indicated that the survival of T-47D cells was significantly compromised in the presence of ZnO-MTCP-conjugated nanostructures with UV light exposure. Exhibition of cytotoxic activity of ZnO-MTCP for human prostate cancer (Du145) cells occurred at a higher concentration, indicating the more resistant nature of these tumor cells. ZnO-CuMTCP showed milder cytotoxic effects in human breast cancer (T-47D) and no cytotoxic effects in Du145 with UV light exposure, consistent with its lower cytotoxic potency as well as cellular uptake. Surprisingly, none of the ZnO-porphyrin conjugates exhibited cytotoxic effects with X-ray irradiation, whereas ZnO alone exerted cytotoxicity. Thus, ZnO and ZnO-porphyrin nanoparticles with UV or X-ray irradiation may provide a suitable treatment option for various cancers. © 2015 International Union of Biochemistry and Molecular Biology, Inc.

  12. X-ray Ordinance

    International Nuclear Information System (INIS)

    Kramer, R.; Zerlett, G.

    1983-01-01

    This commentary, presented as volume 2 of the Deutsches Strahlenschutzrecht (German legislation on radiation protection) deals with the legal provisions of the ordinance on the protection against harmful effects of X-radiation (X-ray Ordinance - RoeV), of March 1, 1973 (announced in BGBl.I, page 173), as amended by the ordinance on the protection against harmful effects of ionizing radiation, of October 13, 1976 (announced in BGBl. I, page 2905). Thus volume 2 completes the task started with volume 1, namely to present a comprehensive view and account of the body of laws governing radiation protection, a task which was thought useful as developments in the FRG led to regulations being split up into the X-ray Ordinance, and the Radiation Protection Ordinance. In order to present a well-balanced commentary on the X-ray Ordinance, it was necessary to discuss the provisions both from the legal and the medical point of view. This edition takes into account the Fourth Public Notice of the BMA (Fed. Min. of Labour and Social Affairs) concerning the implementation of the X-ray Ordinance of January 4, 1982, as well as court decisions and literature published in this field, until September 1982. In addition, the judgment of the Federal Constitutional Court, dated October 19, 1982, concerning the voidness of the law on government liability, and two decisions by the Federal High Court, dated November 23, 1982, concerning the right to have insight into medical reports - of great significance in practice - have been considered. This commentary therefore is up to date with current developments. (orig.) [de

  13. Microstructural Parameters in 8 MeV Electron-Irradiated BOMBYX MORI Silk Fibers by Wide-ANGLE X-Ray Scattering Studies (waxs)

    Science.gov (United States)

    Sangappa, Asha, S.; Sanjeev, Ganesh; Subramanya, G.; Parameswara, P.; Somashekar, R.

    2010-01-01

    The present work looks into the microstructural modification in electron irradiated Bombyx mori P31 silk fibers. The irradiation process was performed in air at room temperature using 8 MeV electron accelerator at different doses: 0, 25, 50 and 100 kGy. Irradiation of polymer is used to cross-link or degrade the desired component or to fix the polymer morphology. The changes in microstructural parameters in these natural polymer fibers have been computed using wide angle X-ray scattering (WAXS) data and employing line profile analysis (LPA) using Fourier transform technique of Warren. Exponential, Lognormal and Reinhold functions for the column length distributions have been used for the determination of crystal size, lattice strain and enthalpy parameters.

  14. Comparative study of two methods of analysis crystallinity, x-ray and DSC, using a linear low density polyethylene (LLDPE) injected, irradiated by gamma radiation

    International Nuclear Information System (INIS)

    Oliveira, Ana C.F. de; Ferreto, Helio F.R.; Parra, Duclerc F.; Lugao, Ademar B.

    2015-01-01

    The linear low density polyethylene (LLDPE) is a linear polymer chain with short chain branching. In this work, the LLDPE was irradiated in 60 Co gamma source with 2000 kCi of activity, in presence of air, with doses of 5, 10, 20, 50 or 100 kGy, at about 5 kGy.h-1 dose rate, at room temperature. After irradiation, the samples were heated for 60 min at 100 deg C to promote recombination and annihilation of residual radicals. LLDPE injected and irradiated samples were characterized to identity the effects of terminal degradation, scission and crosslinking occurred in each dose. In the radiation process has changes in the crystallization and thus it is possible to compare the methods to obtain the percentage of crystallization of PELDB by DSC and X-ray. (author)

  15. Production of haploid plant of 'Banpeiyu' pummelo [Citrus maxima (Burm.) Merr.] by pollination with soft X-ray-irradiated pollen

    International Nuclear Information System (INIS)

    Yahata, Masaki; Yasuda, Kiichi; Kunitake, Hisato; Nagasawa, Kohji; Harusaki, Seiichi; Komatsu, Haruki

    2010-01-01

    To induce haploid plants in Citrus maxima (Burm.) Merr. 'Banpeiyu', we evaluated the effect of pollination with soft X-ray-irradiated pollen on fruit set and seed development, and carried out ovule culture. When 'Banpeiyu' pummelo pistils were pollinated with X-ray-irradiated pollen of 'Fukuhara' sweet orange [C. sinensis (L.) Osbeck], the exposure doses affected the fruit set. The number of seeds per fruit was also affected by the exposure dose, and tended to decrease as the dose increased; however, all developed seeds obtained from these crosses were diploid. In the ovule culture of 'Banpeiyu' pummelo, six embryoids shown haploidy were obtained in all treatments. One haploid plantlet with 9 chromosomes was regenerated from an embryoid in a culture of ovules established 40 days after pollination with 400 Gray (Gy)-irradiated pollen of 'Tosa-buntan' pummelo (C. maxima). This haploid was suggested to be derived from 'Banpeiyu' pummelo by random amplified polymorphic DNA (RAPD) and cleaved amplified polymorphic sequence (CAPS) analysis. (author)

  16. X-ray tube target

    International Nuclear Information System (INIS)

    Weber, R.G.

    1980-01-01

    A target with an improved heat emissive surface for use in a rotating anode type x-ray tube is described. The target consists of a body having a first surface portion made of x-ray emissive material and a second surface portion made of a heat emissive material comprising at least one of hafnium boride, hafnium oxide, hafnium nitride, hafnium silicide, and hafnium aluminide. (U.K.)

  17. X-ray diffuse scattering study of 2 kF and 4 kF anomalies in strongly irradiated TTF-TCNQ

    OpenAIRE

    Forró, L.; Bouffard, S.; Pouget, J.P.

    1984-01-01

    We report an X-ray diffuse scattering study of the CDW fluctuations in strongly irradiated TTF-TCNQ. The 2 kF and 4 kF CDW become onedimensional for 5.0 mol % of introduced defects, even at the lowest temperature (28 K). At the concentration level of 15 mol % the 2 kF anomaly disappears, while a temperature independent 4 kF distortion is stabilized. These results are compared with those for the alloy TTF0.97TSF0.03TCNQ and for TMTSF-DMTCNQ.

  18. Differential superiority of heavy charged-particle irradiation to x-rays: Studies on biological effectivenes and side effect mechanisms in multicellular tumor and normal tissue models

    Directory of Open Access Journals (Sweden)

    Stefan eWalenta

    2016-02-01

    Full Text Available This review is focused on the radiobiology of carbon ions compared to x-rays using multicellular models of tumors and normal mucosa. The first part summarizes basic radiobiological effects, as observed in cancer cells. The second, more clinically oriented part of the review deals with radiation-induced cell migration and mucositis.Multicellular spheroids (MCS from V79 hamster cells were irradiated with x-rays or carbon ions under ambient or restricted oxygen supply conditions. Oxygen enhancement ratios (OER were 2.9, 2.8, and 1.4 for irradiation with photons, 12C+6 in the plateau region, and 12C+6 in the Bragg peak, respectively. A relative biological effectiveness (RBE of 4.3 and 2.1 for ambient pO2 and hypoxia was obtained, respectively. The high effectiveness of carbon ions was reflected by an enhanced accumulation of cells in G2/M, and a dose-dependent massive induction of apoptosis. Clinically relevant doses (3 Gy of x-rays induced an increase in migratory activity of U87 but not of LN229 or HCT116 tumor cells. Such an increase in cell motility following irradiation in situ could be the source of recurrence. In contrast, carbon ion treatment was associated with a dose-dependent decrease in migration with all cell lines and under all conditions investigated. The radiation-induced loss of cell motility was correlated, in most cases, with corresponding changes in 1 integrin expression. Unlike with particles, the photon-induced increase in cell migration was paralleled by an elevated phosphorylation status of the epidermal growth factor receptor (EGFR and AKT-ERK1/2 pathway. Comparing the gene toxicity of x-rays with that of particles using the gamma-H2AX technique in organotypic cultures of the oral mucosa, the superior effectiveness of heavy ions was confirmed by a two-fold higher number of foci per nucleus. Pro-inflammatory signs, however, were similar for both treatment modalities, e. g., the activation of NFkappaB, and the release of IL

  19. Absorption spectra measurements of the x-ray radiation heated SiO2 aerogel plasma in 'dog-bone' targets irradiated by high power laser pulses

    Science.gov (United States)

    Zhang, Y.; Dong, Q.-L.; Wang, S.-J.; Li, Y.-T.; Zhang, J.; Wei, H.-G.; Shi, J.-R.; Zhao, G.; Zhang, J.-Y.; Wen, T.-S.; Zhang, W.-H.; Hu, X.; Liu, S.-Y.; Ding, Y.-K.; Zhang, L.; Tang, Y.-J.; Zhang, B.-H.; Zheng, Z.-J.; Nishimura, H.; Fujioka, S.; Takabe, H.

    2008-05-01

    We studied the opacity effect of the SiO2 aerogel plasma heated by x-ray radiation produced by high power laser pulses irradiating the inner surface of golden 'dog-bone' targets. The PET crystal spectrometer was used to measure the absorption spectra of the plasmas in the range from 6.4 Å to 7.4 Å, among which the line emissions involving the K shell of Si ions from He-like to neutral atom were located. The experimental results were analyzed with Detailed-Level-Accounting method. As the plasma temperature increased, the characteristic lines of highly ionized ions gradually dominated the absorption spectrum.

  20. Estimation of percentage body fat by dual-energy x-ray absorptiometry: evaluation by in vivo human elemental composition

    Energy Technology Data Exchange (ETDEWEB)

    Wang Zimian; Pierson, Richard N [Obesity Research Center, St Luke' s-Roosevelt Hospital, Columbia University, College of Physicians and Surgeons, New York, NY (United States); Heymsfield, Steven B [Clinical Research, Metabolism, Merck Research Laboratories, Rahway, NJ (United States); Chen Zhao [Mel and Enid Zuckerman College of Public Health, University of Arizona, Tucson, AZ (United States); Zhu Shankuan, E-mail: zw28@columbia.ed [Obesity and Body Composition Research Center, Zhejiang University, School of Public Health, Hangzhou (China)

    2010-05-07

    Dual-energy x-ray absorptiometry (DXA) is widely applied for estimating body fat. The percentage of body mass as fat (%fat) is predicted from a DXA-estimated R{sub ST} value defined as the ratio of soft tissue attenuation at two photon energies (e.g., 40 keV and 70 keV). Theoretically, the R{sub ST} concept depends on the mass of each major element in the human body. The DXA R{sub ST} values, however, have never been fully evaluated by measured human elemental composition. The present investigation evaluated the DXA R{sub ST} value by the total body mass of 11 major elements and the DXA %fat by the five-component (5C) model, respectively. Six elements (i.e. C, N, Na, P, Cl and Ca) were measured by in vivo neutron activation analysis, and potassium (i.e. K) by whole-body {sup 40}K counting in 27 healthy adults. Models were developed for predicting the total body mass of four additional elements (i.e. H, O, Mg and S). The elemental content of soft tissue, after correction for bone mineral elements, was used to predict the R{sub ST} values. The DXA R{sub ST} values were strongly associated with the R{sub ST} values predicted from elemental content (r = 0.976, P < 0.001), although there was a tendency for the elemental-predicted R{sub ST} to systematically exceed the DXA-measured R{sub ST} (mean {+-} SD, 1.389 {+-} 0.024 versus 1.341 {+-} 0.024). DXA-estimated %fat was strongly associated with 5C %fat (24.4 {+-} 12.0% versus 24.9 {+-} 11.1%, r = 0.983, P < 0.001). DXA R{sub ST} is evaluated by in vivo elemental composition, and the present study supports the underlying physical concept and accuracy of the DXA method for estimating %fat.

  1. Skinfold thicknesses method to analyse body fat in hemodialysis patients: comparison with dual energy x-ray absorptiometry

    Directory of Open Access Journals (Sweden)

    Viviane O Leal

    2012-06-01

    Full Text Available Nutritional status is a major determinant of the outcome of hemodialysis (HD patients. While protein wasting is associated with morbidity and mortality, high fat mass and central adiposity is also observed in HD population and, related to metabolic disorders. Therefore, body composition assessment is a key point to provide adequate nutritional care to these patients. In this way, practical and reliable indicators of body composition are needed for clinical purposes. Thus, the objective of this study was to evaluate the use of anthropometry as an alternative to dual energy X-ray absorptiometry (DXA, considered the reference method to evaluate body fat in HD patients. Thirty-nine HD patients (52.7±11.3 years, 24 men, BMI, 23.7±4.0 kg/m2, urea clearance (Kt/Vsp of 1.47±0.22 and 64.1±46.1 months on HD were studied. Percentage of body fat (%BF was performed by DXA scans (Prodigy Advanc Plus, Lunar Corp, Madison, WI, USA and anthropometry (biceps, triceps, subscapular and suprailiac skinfold thicknesses after a HD session. Body density was calculated using the formula of Durnin and Womersley (1974 and the %BF was calculated by Siri´s equation (Siri, 1961. The reference values for %BF were considered (Lohman et al., 1991. The mean of %BF assessed by anthopometry and DXA was 25.2±6.9% and 26.8±8.3% for men and 32.8±6.3% and 31.5±8.7% for women, respectively. The most of HD patients presented high %BF (≥25% for men and ≥32% for women: 59.0% by anthropometry and 56.4% by DXA. The paired analysis showed that the %BF assessment was not different when evaluated by anthropometry or DXA methods (p=0.6. The kappa coefficient between DXA and anthropometry was 0.42 (p<0.0001, which is considered as good correlation between two methods. In conclusion, the simple method of skinfold thicknesses is reliable to assess body fat in HD patients when compared to DXA.

  2. Dual energy X-ray absorptiometry positioning protocols in assessing body composition: A systematic review of the literature.

    Science.gov (United States)

    Shiel, Flinn; Persson, Carl; Furness, James; Simas, Vini; Pope, Rodney; Climstein, Mike; Hing, Wayne; Schram, Ben

    2018-03-16

    To systematically identify and assess methods and protocols used to reduce technical and biological errors in published studies that have investigated reliability of dual energy X-ray absorptiometry (DXA) for assessing body composition. Systematic review. Systematic searches of five databases were used to identify studies of DXA reliability. Two independent reviewers used a modified critical appraisal tool to assess their methodological quality. Data was extracted and synthesised using a level of evidence approach. Further analysis was then undertaken of methods used to decrease DXA errors (technical and biological) and so enhance DXA reliability. Twelve studies met eligibility criteria. Four of the articles were deemed high quality. Quality articles considered biological and technical errors when preparing participants for DXA scanning. The Nana positioning protocol was assessed to have a strong level of evidence. The studies providing this evidence indicated very high test-retest reliability (ICC 0.90-1.00 or less than 1% change in mean) of the Nana positioning protocol. The National Health and Nutrition Examination Survey (NHANES) positioning protocol was deemed to have a moderate level of evidence due to lack of high quality studies. However, the available studies found the NHANES positioning protocol had very high test-retest reliability. Evidence is limited and reported reliability has varied in papers where no specific positioning protocol was used or reported. Due to the strong level of evidence of excellent test-retest reliability that supports use of the Nana positioning protocol, it is recommended as the first choice for clinicians when using DXA to assess body composition. Copyright © 2018. Published by Elsevier Ltd.

  3. Predictive Validity of the Body Adiposity Index in Overweight and Obese Adults Using Dual-Energy X-ray Absorptiometry

    Directory of Open Access Journals (Sweden)

    Robinson Ramírez-Vélez

    2016-11-01

    Full Text Available The body adiposity index (BAI is a recent anthropometric measure proven to be valid in predicting body fat percentage (BF% in some populations. However, the results have been inconsistent across populations. This study was designed to verify the validity of BAI in predicting BF% in a sample of overweight/obese adults, using dual-energy X-ray absorptiometry (DEXA as the reference method. A cross-sectional study was conducted in 48 participants (54% women, mean age 41.0 ± 7.3 years old. DEXA was used as the “gold standard” to determine BF%. Pearson’s correlation coefficient was used to evaluate the association between BAI and BF%, as assessed by DEXA. A paired sample t-test was used to test differences in mean BF% obtained with BAI and DEXA methods. To evaluate the concordance between BF% as measured by DEXA and as estimated by BAI, we used Lin’s concordance correlation coefficient and Bland–Altman agreement analysis. The correlation between BF% obtained by DEXA and that estimated by BAI was r = 0.844, p < 0.001. Paired t-test showed a significant mean difference in BF% between methods (BAI = 33.3 ± 6.2 vs. DEXA 39.0 ± 6.1; p < 0.001. The bias of the BAI was −6.0 ± 3.0 BF% (95% CI = −12.0 to 1.0, indicating that the BAI method significantly underestimated the BF% compared to the reference method. Lin’s concordance correlation coefficient was considered stronger (ρc = 0.923, 95% CI = 0.862 to 0.957. In obese adults, BAI presented low agreement with BF% measured by DEXA; therefore, BAI is not recommended for BF% prediction in this overweight/obese sample studied.

  4. Predictive Validity of the Body Adiposity Index in Overweight and Obese Adults Using Dual-Energy X-ray Absorptiometry

    Science.gov (United States)

    Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; Vivas, Andrés; García-Hermoso, Antonio; Triana-Reina, Hector Reynaldo

    2016-01-01

    The body adiposity index (BAI) is a recent anthropometric measure proven to be valid in predicting body fat percentage (BF%) in some populations. However, the results have been inconsistent across populations. This study was designed to verify the validity of BAI in predicting BF% in a sample of overweight/obese adults, using dual-energy X-ray absorptiometry (DEXA) as the reference method. A cross-sectional study was conducted in 48 participants (54% women, mean age 41.0 ± 7.3 years old). DEXA was used as the “gold standard” to determine BF%. Pearson’s correlation coefficient was used to evaluate the association between BAI and BF%, as assessed by DEXA. A paired sample t-test was used to test differences in mean BF% obtained with BAI and DEXA methods. To evaluate the concordance between BF% as measured by DEXA and as estimated by BAI, we used Lin’s concordance correlation coefficient and Bland–Altman agreement analysis. The correlation between BF% obtained by DEXA and that estimated by BAI was r = 0.844, p < 0.001. Paired t-test showed a significant mean difference in BF% between methods (BAI = 33.3 ± 6.2 vs. DEXA 39.0 ± 6.1; p < 0.001). The bias of the BAI was −6.0 ± 3.0 BF% (95% CI = −12.0 to 1.0), indicating that the BAI method significantly underestimated the BF% compared to the reference method. Lin’s concordance correlation coefficient was considered stronger (ρc = 0.923, 95% CI = 0.862 to 0.957). In obese adults, BAI presented low agreement with BF% measured by DEXA; therefore, BAI is not recommended for BF% prediction in this overweight/obese sample studied. PMID:27916871

  5. X-ray diffraction study of the Y{sub 2}Ti{sub 2}O{sub 7} pyrochlore disordering sequence under irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Soulié, Aurélien, E-mail: aurelien.soulie@cea.fr [CEA, DEN, Service de Recherches de Métallurgie Physique, Université Paris-Saclay, F-91191 Gif sur Yvette (France); CEA, DEN, Service de Recherches de Métallurgie Appliqué, Université Paris-Saclay, F-91191 Gif sur Yvette (France); Menut, Denis [CEA, DEN, Service de Recherches de Métallurgie Appliqué, Université Paris-Saclay, F-91191 Gif sur Yvette (France); Crocombette, Jean-Paul [CEA, DEN, Service de Recherches de Métallurgie Physique, Université Paris-Saclay, F-91191 Gif sur Yvette (France); Chartier, Alain [CEA, DEN, Service de la Corrosion et du Comportement des Matériaux dans leur Environnement, Laboratoire de Modélisation, de Thermodynamique et de Thermochimie, Université Paris-Saclay, F-91191 Gif sur Yvette (France); Sellami, Neila [Univ. Paris Sud, ICMMO-SP2M, Bât. 410, F-91405 Orsay (France); Sattonnay, Gaël [Univ. Paris-Sud, CSNSM, CNRS, IN2P3, Bât. 108, F-91405 Orsay (France); Monnet, Isabelle [CIMAP, CEA, CNRS, Université de Caen, BP 5133, F-14070 Caen Cedex 5 (France); and others

    2016-11-15

    The disordering sequence of Y{sub 2}Ti{sub 2}O{sub 7} pyrochlore, a nano-oxide phase that strengthens ODS steels under irradiation is studied in the experimental and modeling framework. XRD analysis has been performed considering both swift heavy ion and low energy/low mass ion irradiations. The simulation within molecular dynamics of Frenkel pair accumulation proves able to reproduce the variation of the amorphization fluence with temperature. XRD patterns calculated from the simulations reproduce well the patterns observed experimentally in the literature. Both experiments and calculations point to a first transition from pyrochlore to fluorite before an eventual amorphization. For swift heavy ion irradiations with 93 MeV Xe ions, tracks of direct impact amorphization are visible by HRTEM. Advanced refinement shows that one third of the pyrochlore impacted by an ion transforms into fluorite, while two third are directly amorphized. - Highlights: • A comparison between swift heavy ion and low energy/low mass ion irradiation of Y{sub 2}Ti{sub 2}O{sub 7} pyrochlore is performed. • Simulations of the irradiation with Molecular dynamics reproduce the amorphization dose at low energy/mass ion irradiation. • Advanced refinement of X-ray diffraction patterns gives the evolution of phase fractions in pyrochlore under irradiation. • The disordering sequence a transition from pyrochlore to defect fluorite before an eventual amorphization.

  6. In situ high-energy X-ray diffraction study of tensile deformation of neutron-irradiated polycrystalline Fe-9%Cr alloy

    International Nuclear Information System (INIS)

    Zhang, Xuan; Li, Meimei; Park, Jun-Sang; Kenesei, Peter; Almer, Jonathan

    2016-01-01

    The effect of neutron irradiation on tensile deformation of a Fe-9wt.%Cr alloy was investigated using in situ high-energy synchrotron X-ray diffraction during room-temperature uniaxial tensile tests. New insights into the deformation mechanisms were obtained through the measurements of lattice strain evolution and the analysis of diffraction peak broadening using the modified Williamson-Hall method. Two neutron-irradiated specimens, one irradiated at 300 °C to 0.01 dpa and the other at 450 °C to 0.01dpa, were tested along with an unirradiated specimen. The macroscopic stress–strain curves of the irradiated specimens showed increased strength, reduced ductility and work-hardening exponent compared to the unirradiated specimen. The evolutions of the lattice strain, the dislocation density and the coherent scattering domain size in the deformation process revealed different roles of the submicroscopic defects in the 300°C/0.01 dpa specimen and the TEM-visible nanometer-sized dislocation loops in the 450°C/0.01 dpa specimen: submicroscopic defects extended the linear work hardening stage (stage II) to a higher strain, while irradiation-induced dislocation loops were more effective in dislocation pinning. Lastly, while the work hardening rate of stage II was unaffected by irradiation, significant dynamic recovery in stage III in the irradiated specimens led to the early onset of necking without stage IV as observed in the unirradiated specimen.

  7. Determination of dose enhancement caused by gold-nanoparticles irradiated with proton, X-rays (kV and MV) and electron beams, using alanine/EPR dosimeters

    International Nuclear Information System (INIS)

    Smith, Clare L.; Ackerly, Trevor; Best, Stephen P.; Gagliardi, Frank; Kie, Katahira; Little, Peter J.; McCorkell, Giulia; Sale, Charlotte A.; Tsunei, Yusuke; Tominaga, Takahiro; Volaric, Sioe See; Geso, Moshi

    2015-01-01

    The main aims of this research was to employ alanine doped with gold-nanoparticles “AuNPs” to determine the levels of dose enhancement caused by these particles when irradiated with proton beams, low and high energy X-rays and electrons. DL-alanine was impregnated with 5 nm gold-nanoparticles (3% by weight) and added as a uniform layer within a wax pellet of dimensions 10 × 5 × 5 mm. Control pellets, containing DL-Alanine were also produced, and placed within a phantom, and exposed to various types of radiations: low energy (kV ranges) X-rays were obtained from a superficial machine, high energy (MV) X-rays and electrons derived from a linear accelerator, and protons were produced by the Hyogo Ion Beam Centre in Japan. Nominal doses received ranged from 2 to 20 Gy (within clinical range). The Electron Paramagnetic Resonance (EPR) spectra of the irradiated samples were recorded on a BRUKER Elexsys 9.5 MHz. The dose enhancement caused by gold nanoparticles for 80 kV x-rays was found to be more than 60% at about 5 Gy. Smaller dose enhancements (under the same measurement conditions) were observed for megavoltage x-ray beams (up to 10%). Dose enhancement caused by charged particles indicated minimal values for 6 MeV electrons (approximately 5%) whilst less than that is obtained with protons of 150 MeV. The proton results validate the latest simulation results based on Monte Carlo calculations but the dose enhancement is significantly less than that reported in cell and animal model systems, (about 20%). We attribute this difference to the fact that alanine only measures the levels of free radicals generated by the inclusion of nanoparticles and not the redox type radicals (such as reactive oxygen species) generated from aqueous media in cells. Dose enhancement caused by 5 nm gold-nanoparticles with radiotherapy type proton beams has been found to be less than 5% as determined when using alanine/wax as both a phantom and dosimeter. This agrees well

  8. Arrangement for X-ray shield

    International Nuclear Information System (INIS)

    1980-01-01

    X-ray screen unit consisting of a light transmissive carrier onto which scintillation material is deposited, which is able to generate light under the influence of incident X-ray irradiation, characterised in that the X-ray screen comprises a number of sectors, wherein the surface with respect to the incident X-radiation is maintained at an acute angle. (G.C.)

  9. Reproducibility of pediatric whole body bone and body composition measures by dual-energy X-ray absorptiometry using the GE Lunar Prodigy.

    Science.gov (United States)

    Margulies, Lauren; Horlick, Mary; Thornton, John C; Wang, Jack; Ioannidou, Elli; Heymsfield, Steven B

    2005-01-01

    The use of dual-energy X-ray absorptiometry (DXA) in pediatrics is increasing. It is safe, readily available, and easily performed, but there is little information on reproducibility. The aim of this study is to evaluate the reproducibility of whole body DXA scans in children. Total and regional bone mineral density, bone mineral content, nonbone, lean fat mass, and percent fat were measured twice by whole body DXA (GE Lunar Prodigy) in 49 subjects (5 to 17 yr). Within each subject, between subjects, and reading standard deviations for each body component were evaluated as well as intraclass correlations (IC) and coefficients of variation (CV). Total body measurements had better IC and CV than regional results from the whole body scan, with legs and arms better than trunk and spine. IC values were >or=0.989 for total body, >or=0.976 for legs and arms, and >or=0.875 for trunk and spine. CV values ranged 0.18 to 1.97% for total body, and 0.96 to 6.91% for regional measures. These values confirm that body composition and bone mass by DXA are highly reproducible among pediatric subjects. The results of this study can be used by clinicians and researchers for interpretation of longitudinal observations and for power calculations.

  10. Development of an ionization chamber based high sensitivity detector for the measurement of radiation dose from X-ray whole body scanners

    International Nuclear Information System (INIS)

    Singh, Sunil K.; Tripathi, S.M.; LijiShaiju; Sathian, V.; Kulkarni, M.S.

    2016-01-01

    Using walk through metal detectors and undergoing frisking for personals at airports, seaports, railway stations and other sensitive places no longer meets proper security requirements. Now a days use of plastic explosives, drug trafficking or illegal carriage of dangerous items concealed under cloths or body cavities has increased many folds which in many cases is not possible to detect by conventional methods. One of the systems which are capable to overcome the above mentioned difficulties is the use of X-ray based whole body scanners, either transmission type or backscatter type, depending upon the nature of requirement. While using these whole body scanners the person being scanned possesses a radiation risk whose safety aspects can be monitored by following international standards (recommending certain dose limits). In order to check the compliance of these dose limits, the dose per scan received by the person (from these whole body scanners) needs to be measured. A very high sensitive ionization chamber has been designed and fabricated for measuring these extremely low X- ray fields ( few μR) produced by a scanning X-ray beam over a large area. A methodology has been developed to measure exposure per scan using large volume ionization chambers. This value of exposure was used to calculate whole body dose as per the recommendations of ANSI standard for its compliance

  11. Effects of X-ray irradiation on the luminescent properties of Eu-doped LiSrPO4 phosphors produced using the sol-gel method with glucose

    Science.gov (United States)

    Nascimento, Patresio A. M.; Silva, Ariosvaldo J. S.; Andrade, Adriano B.; Silva, Ronaldo S.; Rezende, Marcos V. dos S.

    2018-02-01

    Eu-doped LiSrPO4 (LSPO) phosphors were prepared using a sol-gel method, both with and without a chelating agent (glucose), and the effects of X-ray irradiation on the luminescence properties were investigated. The phase formation was carried out using X-ray diffraction (XRD). Optical properties such as photoluminescence (PL), spectroscopy excitation and emission, radioluminescence (RL) and photoluminescence emission after X-ray irradiated samples were examined. The results show that the sol-gel route without a chelating agent or the use of glucose is a reliable method for the synthesis of Eu-doped LSPO phosphors. The results also demonstrated an improvement in the luminescence for the sample produced without glucose. The PL and RL spectra showed different behavior; this behavior was connected to the X-ray absorption/reduction process of the Eu ions.

  12. The relationship between cell survival rate and telomerase activity of the human hepatocellular cells and carcinoma cells irradiated by X-rays

    International Nuclear Information System (INIS)

    Liu Jinting; Dang Bingrong; Li Wenjian; Jing Xigang; Wei Wei; Wang Zhuanzi; Ding Nan; Gao Qingxiang

    2010-01-01

    In this paper, the relationship between cell survival fraction and telomerase activity was investigated with the human hepatocellular cells HL-7702 and carcinoma cells SMMC-7721 irradiated by X-rays. The colony formation assay and TRAP (Telomeric repeat amplification protocol) method were used to determine the cell survival fraction and telomerase activity respectively. To both of HL-7702 and SMMC-7721, the telomerase activity was increased in dose-dependent. However, at 1-3 Gy, the telomerase activity was lower than that of control in SMMC-7721, and it was a little higher than that of control when irradiated at 4 Gy. At 1-4 Gy, the variation trend of cell survive and that of telomerase activity were identical. (authors)

  13. The effect of electron irradiation on high-density polyethylene: Positron annihilation lifetime spectroscopy, differential scanning calorimetry and X-ray scattering studies

    Energy Technology Data Exchange (ETDEWEB)

    Zaydouri, A. [Laboratoire de Chimie-Physique et Rayonnement-Alain Chambaudet, UMR CEA E4, Universite de Franche Comte, 16 route de Gray, 25030 Besancon Cedex (France)], E-mail: zaydouri@hotmail.com; Grivet, M. [Laboratoire de Chimie-Physique et Rayonnement-Alain Chambaudet, UMR CEA E4, Universite de Franche Comte, 16 route de Gray, 25030 Besancon Cedex (France)], E-mail: manuel.grivet@univ-fcomte.fr

    2009-09-15

    Electron irradiation effects in HDPE have been studied using positron annihilation lifetime spectroscopy. In the four-component analysis of a spectrum, two long-lived states are ascribed to ortho-positronium (o-Ps) annihilation in the crystalline phase and in the amorphous phase. The study of the o-Ps parameters highlights the different behaviour of the two phases. From the o-Ps lifetime in the crystalline phase, it is shown that the effect of irradiation is larger at 250 kGy. Thermal analysis (DSC) reveals two different melting temperatures and also an increase in the fusion enthalpy, at 250 kGy. This phenomenon induced by an electron beam is erased by thermal treatment: fusion and re-crystallisation. However, before and after thermal treatment no changes are observed in the crystallite size and in the crystalline rate using wide-angle X-ray scattering.

  14. X-ray apparatus

    International Nuclear Information System (INIS)

    Sell, L.J.

    1981-01-01

    A diagnostic x-ray device, readily convertible between conventional radiographic and tomographic operating modes, is described. An improved drive system interconnects and drives the x-ray source and the imaging device through coordinated movements for tomography

  15. X-ray - skeleton

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003381.htm X-ray - skeleton To use the sharing features on this ... Degenerative bone conditions Osteomyelitis Risks There is low radiation exposure. X-rays machines are set to provide the smallest ...

  16. Dental x-rays

    Science.gov (United States)

    X-ray - teeth; Radiograph - dental; Bitewings; Periapical film; Panoramic film; Digital image ... dentist's office. There are many types of dental x-rays. Some of them are: Bitewing. Shows the crown ...

  17. Chest X-Ray

    Medline Plus

    Full Text Available ... some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a ... posted: How to Obtain and Share ...

  18. Influence of Xe and Kr impurities on x-ray yield from debris-free plasma x-ray sources with an Ar supersonic gas jet irradiated by femtosecond near-infrared-wavelength laser pulses.

    Science.gov (United States)

    Kantsyrev, V L; Schultz, K A; Shlyaptseva, V V; Petrov, G M; Safronova, A S; Petkov, E E; Moschella, J J; Shrestha, I; Cline, W; Wiewior, P; Chalyy, O

    2016-11-01

    Many aspects of physical phenomena occurring when an intense laser pulse with subpicosecond duration and an intensity of 10^{18}-10^{19}W/cm^{2} heats an underdense plasma in a supersonic clustered gas jet are studied to determine the relative contribution of thermal and nonthermal processes to soft- and hard-x-ray emission from debris-free plasmas. Experiments were performed at the University of Nevada, Reno (UNR) Leopard laser operated with a 15-J, 350-fs pulse and different pulse contrasts (10^{7} or 10^{5}). The supersonic linear (elongated) nozzle generated Xe cluster-monomer gas jets as well as jets with Kr-Ar or Xe-Kr-Ar mixtures with densities of 10^{18}-10^{19}cm^{-3}. Prior to laser heating experiments, all jets were probed with optical interferometry and Rayleigh scattering to measure jet density and cluster distribution parameters. The supersonic linear jet provides the capability to study the anisotropy of x-ray yield from laser plasma and also laser beam self-focusing in plasma, which leads to efficient x-ray generation. Plasma diagnostics included x-ray diodes, pinhole cameras, and spectrometers. Jet signatures of x-ray emission from pure Xe gas, as well as from a mixture with Ar and Kr, was found to be very different. The most intense x-ray emission in the 1-9 KeV spectral region was observed from gas mixtures rather than pure Xe. Also, this x-ray emission was strongly anisotropic with respect to the direction of laser beam polarization. Non-local thermodynamic equilibrium (Non-LTE) models have been implemented to analyze the x-ray spectra to determine the plasma temperature and election density. Evidence of electron beam generation in the supersonic jet plasma was found. The influence of the subpicosecond laser pulse contrast (a ratio between the laser peak intensity and pedestal pulse intensity) on the jets' x-ray emission characteristics is discussed. Surprisingly, it was found that the x-ray yield was not sensitive to the prepulse contrast ratio.

  19. Overutilization of x-rays

    International Nuclear Information System (INIS)

    Abrams, H.L.

    1979-01-01

    In this article on the overutilization of x-rays the author defines the term overutilization as excessive irradiation per unit of diagnostic information, therapeutic impact, or health outcome. Three main factors are described which lead to overutilization of x-rays: excessive radiation per film; excessive films per examination; and excessive examinations per patient. Topics discussed which influence the excessive examinations per patient are: the physician's lack of knowledge; undue dependence; lack of screening by radiologists; the physician's need for action and certainty; patient demand; reimbursement policies; institutional requirements; preventive medicine; defensive medicine; and the practice of radiology by nonradiologists

  20. Repetitive flash x-ray generator as an energy transfer source utilizing a compact-glass body diode

    Science.gov (United States)

    Shikoda, Arimitsu; Sato, Eiichi; Kimura, Shingo; Isobe, Hiroshi; Takahashi, Kei; Tamakawa, Yoshiharu; Yanagisawa, Toru

    1991-04-01

    The studies of a repetitive flash x-ray generator as an energy source achieved with a compact diode with a permeable anode are described. This source consisted of the following essential components: a constant negative high-voltage power supply of up to -100kV, a modified two-stage Marx pulser, a repetitive trigger device, and an x-ray tube. Two condensers in the pulser were charged from -50 to -80kV, and the output voltages (no-load) were less than -130kV. Since the capacity of each condenser was 85OpF, the total capacity during discharge was 425pF. The maximum tube voltage and the tube current were about 85kV and 0. 3kA, respectively. The xray pulse widths were less than l2Ons, and the repetitive rate was less than 40Hz. The time-integrated x-ray intensity was about 25pC/kg at 24mm per pulse with a charged voltage of 60kV and an anode-cathode (A-C) space of 9. 0mm, and the maximum size of the x-ray source was equivalent to an anode diameter of 27mm.

  1. Comparison of x-ray output of inverter-type x-ray equipment

    International Nuclear Information System (INIS)

    Asano, Hiroshi; Miyake, Hiroyuki; Yamamoto, Keiichi

    2000-01-01

    The x-ray output of 54 inverter-type x-ray apparatuses used at 18 institutions was investigated. The reproducibility and linearity of x-ray output and variations among the x-ray equipment were evaluated using the same fluorescence meter. In addition, the x-ray apparatuses were re-measured using the same non-invasive instrument to check for variations in tube voltage, tube current, and irradiation time. The non-invasive instrument was calibrated by simultaneously obtaining measurements with an invasive instrument, employing the tube voltage and current used for the invasive instrument, and the difference was calculated. Reproducibility of x-ray output was satisfactory for all x-ray apparatuses. The coefficient of variation was 0.04 or less for irradiation times of 5 ms or longer. In 84.3% of all x-ray equipment, variation in the linearity of x-ray output was 15% or less for an irradiation time of 5 ms. However, for all the apparatuses, the figure was 50% when irradiation time was the shortest (1 to 3 ms). Variation in x-ray output increased as irradiation time decreased. Variation in x-ray output ranged between 1.8 and 2.5 compared with the maximum and minimum values, excluding those obtained at the shortest irradiation time. The relative standard deviation ranged from ±15.5% to ±21.0%. The largest variation in x-ray output was confirmed in regions irradiated for the shortest time, with smaller variations observed for longer irradiation times. The major factor responsible for variation in x-ray output in regions irradiated for 10 ms or longer, which is a relatively long irradiation time, was variation in tube current. Variation in tube current was slightly greater than 30% at maximum, with an average value of 7% compared with the preset tube current. Variations in x-ray output in regions irradiated for the shortest time were due to photographic effects related to the rise and fall times of the tube voltage waveform. Accordingly, in order to obtain constant x-ray

  2. Influence of X-rays on oogenesis in Tilapia mossambica. 3. Irradiation of 20 days old larvae

    International Nuclear Information System (INIS)

    Chmilevskij, D.A.

    1985-01-01

    Tilapia mossambica Peters larvae of 20 days old after hatching were irradiated with a dose of 350 R. Gonads recovery in irradiated fishes began from the age of 95 days; anatomic sexual differentiation in gonads delayed; death of developing oocytes was noted: gonads development in the irradiated fishes of 144 days old was sharply suppressed, some fishes were sterile

  3. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... you about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed ...

  4. Study of fission products (Cs, Ba, Mo, Ru) behaviour in irradiated and simulated nuclear fuels during severe accidents using X-ray absorption Spectroscopy, SIMS and EPMA

    International Nuclear Information System (INIS)

    Geiger, Ernesto

    2016-01-01

    The identification of Fission Products (FP) release mechanism from irradiated nuclear fuels during a severe accident is of main importance for the development of codes for the estimation of the source-term (nature and quantity of radionuclides released into the environment). among the many FP Ba, Cs, Mo and Ru present a particular interest, since they may interact with each other or other elements and thus affect their release. In the framework of this thesis, two work axes have been set up in order to identify, firstly, the chemical phases initially present before the accident and, secondly, their evolution during the accident itself. The experimental approach consisted in reproducing nuclear severe accidents conditions at laboratory scale using both irradiated fuels and model materials (natural UO 2 doped with 12 FP). The advantage of these latter is the possibility of using characterization methods such as X-ray absorption Spectroscopy which are not available for irradiated fuels. Three irradiated fuel samples have been studied, representative to an initial state (before the accident), to an intermediate stage (1773 K) and to an advanced stage (2873 K) of a nuclear severe accident. Regarding to model materials, many accident sequences have been carried out, from 573 to 1973 K. Experimental results have allowed to establish a new release mechanism, considering both reducing and oxidizing conditions during an accident. These results have also demonstrated the importance of model materials as a complement to irradiated nuclear fuels in the study of nuclear severe accidents. (author) [fr

  5. Effect of high energy X-ray irradiation on the nano-mechanical properties of human enamel and dentine

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Xue; Zhang, Jing Yang; Cheng, Iek Ka [State Key Laboratory of Oral Diseases, Sichuan University, Chengdu (China); Li, Ji Yao, E-mail: jiyao_li@aliyun.com [West China School of Stomatology, Sichuan University, Chengdu (China)

    2016-05-01

    Radiotherapy for malignancies in the head and neck can cause common complications that can result in tooth damage that are also known as radiation caries. The aim of this study was to examine damage to the surface topography and calculate changes in friction behavior and the nano-mechanical properties (elastic modulus, nano hardness and friction coefficient) of enamel and dentine from extracted human third molars caused by exposure to radiation. Enamel and dentine samples from 50 human third molars were randomly assigned to four test groups or a control group. The test groups were exposed to high energy X-rays at 2 Gy/day, 5 days/week for 5 days (10 Gy group), 15 days (30 Gy group), 25 days (50 Gy group), 35 days (70 Gy group); the control group was not exposed. The nano hardness, elastic modulus, and friction coefficient were analyzed using a Hysitron Triboindenter. The nano-mechanical properties of both enamel and dentine showed significant dose-response relationships. The nano hardness and elastic modulus were most variable between 30-50 Gy, while the friction coefficient was most variable between 0-10 Gy for dentine and 30-50 Gy for enamel. After exposure to X-rays, the fracture resistance of the teeth clearly decreased (rapidly increasing friction coefficient with increasing doses under the same load), and they were more fragile. These nano-mechanical changes in dental hard tissue may increase the susceptibility to caries. Radiotherapy caused nano-mechanical changes in dentine and enamel that were dose related. The key doses were 30-50 Gy and the key time points occurred during the 15{sup th}-25{sup th} days of treatment, which is when application of measures to prevent radiation caries should be considered. (author)

  6. A Co-culture Method to Investigate the Crosstalk Between X-ray Irradiated Caco-2 Cells and PBMC.

    Science.gov (United States)

    Babini, Gabriele; Morini, Jacopo; Barbieri, Sofia; Baiocco, Giorgio; Ivaldi, Giovanni Battista; Liotta, Marco; Tabarelli de Fatis, Paola; Ottolenghi, Andrea

    2018-01-30

    The protocol adopted in this work aims at unraveling how X-rays perturb the functioning of the intestinal barrier, focusing on the interplay between colorectal tumor cells and the immune system. Colorectal carcinoma is among the most common type of cancer, typically treated by surgery, chemotherapy, and radiotherapy. Advantages of radiotherapy in targeting the tumor are well known. However, even limited exposures of healthy tissues are of great concern, particularly regarding the effects on the intestinal barrier and the immune system. The adopted setup allows to study the interplay between two cell populations in a condition more similar to the physiological one, when compared to normal cell cultures. For this purpose, we resort to different techniques and we used an in vitro co-culture model, based on Caco-2 cells differentiated as a monolayer and PBMC, sharing the same culture medium. This protocol has been developed to focus on both macroscopic effects, i.e. cell viability and Trans-Epithelial Electrical Resistance (TEER), and, through western blot, molecular alterations, i.e. the activation of inflammatory pathway in immune cells and the tight junction protein expression in Caco-2 cells. Initial evaluation of radiation effects on Caco-2 cell viability was assessed via the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) and Trypan blue assays, while TEER was measured at fixed time intervals through an ohmmeter specifically designed for co-culture systems. In this way, the effects due to radiation, the presence of Peripheral Blood Mononuclear Cells (PBMC), and eventually their synergistic effect, can be demonstrated. Through these complementary techniques, we observed a high radio-resistance of Caco-2 within the range of 2 - 10 Gy of X-rays and an increased Caco-2 monolayer permeability when PBMCs were added. In particular, PBMC presence was found to be associated with the variation in the tight junction scaffold proteins expression.

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ... This ensures that those parts of a patient's body not being imaged receive minimal radiation ... x-ray images are among the clearest, most detailed views of ...

  8. Differential Superiority of Heavy Charged-Particle Irradiation to X-Rays: Studies on Biological Effectiveness and Side Effect Mechanisms in Multicellular Tumor and Normal Tissue Models

    Science.gov (United States)

    Walenta, Stefan; Mueller-Klieser, Wolfgang

    2016-01-01

    This review is focused on the radiobiology of carbon ions compared to X-rays using multicellular models of tumors and normal mucosa. The first part summarizes basic radiobiological effects, as observed in cancer cells. The second, more clinically oriented part of the review, deals with radiation-induced cell migration and mucositis. Multicellular spheroids from V79 hamster cells were irradiated with X-rays or carbon ions under ambient or restricted oxygen supply conditions. Reliable oxygen enhancement ratios could be derived to be 2.9, 2.8, and 1.4 for irradiation with photons, 12C+6 in the plateau region, and 12C+6 in the Bragg peak, respectively. Similarly, a relative biological effectiveness of 4.3 and 2.1 for ambient pO2 and hypoxia was obtained, respectively. The high effectiveness of carbon ions was reflected by an enhanced accumulation of cells in G2/M and a dose-dependent massive induction of apoptosis. These data clearly show that heavy charged particles are more efficient in sterilizing tumor cells than conventional irradiation even under hypoxic conditions. Clinically relevant doses (3 Gy) of X-rays induced an increase in migratory activity of U87 but not of LN229 or HCT116 tumor cells. Such an increase in cell motility following irradiation in situ could be the source of recurrence. In contrast, carbon ion treatment was associated with a dose-dependent decrease in migration with all cell lines and under all conditions investigated. The radiation-induced loss of cell motility was correlated, in most cases, with corresponding changes in β1 integrin expression. The photon-induced increase in cell migration was paralleled by an elevated phosphorylation status of the epidermal growth factor receptor and AKT-ERK1/2 pathway. Such a hyperphosphorylation did not occur during 12C+6 irradiation under all conditions registered. Comparing the gene toxicity of X-rays with that of particles using the γH2AX technique in organotypic cultures of the oral mucosa, the

  9. Differential Superiority of Heavy Charged-Particle Irradiation to X-Rays: Studies on Biological Effectiveness and Side Effect Mechanisms in Multicellular Tumor and Normal Tissue Models.

    Science.gov (United States)

    Walenta, Stefan; Mueller-Klieser, Wolfgang

    2016-01-01

    This review is focused on the radiobiology of carbon ions compared to X-rays using multicellular models of tumors and normal mucosa. The first part summarizes basic radiobiological effects, as observed in cancer cells. The second, more clinically oriented part of the review, deals with radiation-induced cell migration and mucositis. Multicellular spheroids from V79 hamster cells were irradiated with X-rays or carbon ions under ambient or restricted oxygen supply conditions. Reliable oxygen enhancement ratios could be derived to be 2.9, 2.8, and 1.4 for irradiation with photons, (12)C(+6) in the plateau region, and (12)C(+6) in the Bragg peak, respectively. Similarly, a relative biological effectiveness of 4.3 and 2.1 for ambient pO2 and hypoxia was obtained, respectively. The high effectiveness of carbon ions was reflected by an enhanced accumulation of cells in G2/M and a dose-dependent massive induction of apoptosis. These data clearly show that heavy charged particles are more efficient in sterilizing tumor cells than conventional irradiation even under hypoxic conditions. Clinically relevant doses (3 Gy) of X-rays induced an increase in migratory activity of U87 but not of LN229 or HCT116 tumor cells. Such an increase in cell motility following irradiation in situ could be the source of recurrence. In contrast, carbon ion treatment was associated with a dose-dependent decrease in migration with all cell lines and under all conditions investigated. The radiation-induced loss of cell motility was correlated, in most cases, with corresponding changes in β1 integrin expression. The photon-induced increase in cell migration was paralleled by an elevated phosphorylation status of the epidermal growth factor receptor and AKT-ERK1/2 pathway. Such a hyperphosphorylation did not occur during (12)C(+6) irradiation under all conditions registered. Comparing the gene toxicity of X-rays with that of particles using the γH2AX technique in organotypic cultures of the oral

  10. Total body irradiation: current indications

    International Nuclear Information System (INIS)

    Giraud, P.; Danhier, S.; Dubray, B.; Cosset, J.M.

    1998-01-01

    The choice of dose and fractionation for total body irradiation is made difficult by the large number of considerations to be taken into account. The outcome of bone marrow transplantation after total body irradiation can be understood in terms of tumor cell killing, engraftment, and normal tissue damage, each of these endpoints being influenced by irradiation-, disease-, transplant-, and patient- related factors. Interpretation of clinical data is further hampered by the overwhelming influence of logistic constraints, the small numbers of randomized studies, and the concomitant variations in total dose and fraction size or dose rate. So far, three cautious conclusions can be drawn in order to tentatively adapt the total body irradiation schedule to clinically-relevant situations. Firstly, the organs at risk for normal tissue damage (lung, liver, lens, kidney) are protected by delivering small doses per fraction at low dose rate. This suggests that, when toxicity is at stake (e.g. in children), fractionated irradiation should be preferred, provided that inter-fraction intervals are long enough. Secondly, fractionated irradiation should be avoided in case of T-cell depleted transplant, given the high risk of graft rejection in this setting. An alternative would be to increase total (or fractional) dose of fractionated total body irradiation, but this approach is likely to induce more normal tissue toxicity. Thirdly, clinical data have shown higher relapse rates in chronic myeloid leukemia after fractionated or low dose rate total body irradiation, suggesting that fractionated irradiation should not be recommended, unless total (or fractional) dose is increased. Total body irradiation-containing regimens, primarily cyclophosphamide / total body irradiation, are either equivalent to or better than the chemotherapy-only regimens, primarily busulfan / cyclophosphamide. Busulfan / cyclophosphamide certainly represents a reasonable alternative, especially in patients who

  11. Flash X-ray

    International Nuclear Information System (INIS)

    Sato, Eiichi

    2003-01-01

    Generation of quasi-monochromatic X-ray by production of weakly ionized line plasma (flash X-ray), high-speed imaging by the X-ray and high-contrast imaging by the characteristic X-ray absorption are described. The equipment for the X-ray is consisted from the high-voltage power supply and condenser, turbo molecular pump, and plasma X-ray tube. The tube has a long linear anticathode to produce the line plasma and flash X-ray at 20 kA current at maximum. X-ray spectrum is measured by the imaging plate equipped in the computed radiography system after diffracted by a LiF single crystal bender. Cu anticathode generates sharp peaks of K X-ray series. The tissue images are presented for vertebra, rabbit ear and heart, and dog heart by X-ray fluoroscopy with Ce anticathode. Generation of K-orbit characteristic X-ray with extremely low bremsstrahung is to be attempted for medical use. (N.I.)

  12. Effect of Hind-Limb Suspension and X-Ray Irradiation on the Mechanical and Chemical Properties of Rat Femur and Tibia Bones

    Science.gov (United States)

    Heacox, Hayley; Hill, Brent; Mehta, Rahul; Barajas, Jordan; Freyaldenhoven, Sidney; Dobretsov, Max; Chowdhury, Parimal

    It is known that space conditions such as microgravity and cosmic radiation have detrimental effects on the skeletal system of humans, such as decreased bone mineral density. This research studies the changes in mechanical properties, elasticity, and chemical properties, calcium and phosphorus content, of rat femur and tibia bones when exposed to hind-limb suspension and x-ray irradiation, simulated microgravity and cosmic radiation. It is hypothesized that if microgravity and cosmic radiation lead to decreased bone mineral density, then these conditions will produce weakened bones, lower elastic moduli and abnormal concentrations of calcium and phosphorus, as compared to bones not subject to these conditions. A technique known as three-point bending was employed to estimate the Young's (elastic) modulus for the leg bones. To investigate the chemical nature of the bones, a Scanning Electron Microscope (SEM) was utilized to take cross-sectional images and to perform energy dispersive x-ray spectroscopy. Ultimately, the results produced by this research will aid in quantifying the effects of spaceflight and may be used in developing a treatment to counteract such effects. This work supported by a RID and CRP Grant from Arkansas Space Grant Consortium.

  13. New Solar Soft X-Ray (SXR) Spectral Irradiance Measurements Bridge the SDO and RHESSI Spectral Gap to Study Flare Energetics

    Science.gov (United States)

    Woods, T. N.; Jones, A.; Mason, J.; Moore, C.; Eparvier, F.; Caspi, A.; Chamberlin, P.

    2016-10-01

    The extreme ultraviolet (EUV) spectrum is rich in many different emission lines that reveal plasma characteristics concerning active region evolution and explosive energy release during coronal eruptions. Solar EUV imagers, such as SDO AIA, provide insight into the location, thermal structure, and dynamics of the coronal eruptions and associated flares. In addition, the solar EUV spectral irradiance from SDO EVE, with its higher spectral resolution, provides more detailed thermal evolution of the eruption and has better characterized some aspects of the eruptions such as relationship of coronal dimming and mass loss and post-eruption coronal loop cooling. Complementary to SDO are hard x-ray (HXR) measurements by RHESSI that have clarified the initiation of energy release from magnetic reconnection in the corona. New solar soft x-ray (SXR) spectral irradiance from the Miniature X-ray Solar Spectrometer (MinXSS) CubeSat is now bridging this spectral gap between SDO EUV and RHESSI HXR observations. MinXSS-1 was deployed from the ISS in May 2016 for a 1-year mission, and MinXSS-2 is being launched in October 2016 for a 5-year mission. The energy release during solar flares is expected to peak in the SXR and thus the SXR has been monitored with GOES broadband photometers for decades, but there has been very limited SXR spectral measurements. With the new and unique MinXSS measurements of the SXR spectral variability during flares, coupled with solar SXR images from Hinode, EUV data from SDO, and HXR data from RHESSI, the processes for releasing energy during an eruption and affecting post-eruption thermal evolution can be explored in more detail. Furthermore, the new SXR spectral irradiance measurements can help improve the accuracy of broad band SXR measurements by GOES XRS, SDO EVE ESP, and XPS aboard TIMED and SORCE. Such improvements can lead to better understanding the solar impacts in Earth's ionosphere and thermosphere and how they might affect some of our space

  14. Prediction of Android and Gynoid Body Adiposity via a Three-dimensional Stereovision Body Imaging System and Dual-Energy X-ray Absorptiometry.

    Science.gov (United States)

    Lee, Jane J; Freeland-Graves, Jeanne H; Pepper, M Reese; Stanforth, Philip R; Xu, Bugao

    2015-01-01

    Current methods for measuring regional body fat are expensive and inconvenient compared to the relative cost-effectiveness and ease of use of a stereovision body imaging (SBI) system. The primary goal of this research is to develop prediction models for android and gynoid fat by body measurements assessed via SBI and dual-energy x-ray absorptiometry (DXA). Subsequently, mathematical equations for prediction of total and regional (trunk, leg) body adiposity were established via parameters measured by SBI and DXA. A total of 121 participants were randomly assigned into primary and cross-validation groups. Body measurements were obtained via traditional anthropometrics, SBI, and DXA. Multiple regression analysis was conducted to develop mathematical equations by demographics and SBI assessed body measurements as independent variables and body adiposity (fat mass and percentage fat) as dependent variables. The validity of the prediction models was evaluated by a split sample method and Bland-Altman analysis. The R(2) of the prediction equations for fat mass and percentage body fat were 93.2% and 76.4% for android and 91.4% and 66.5% for gynoid, respectively. The limits of agreement for the fat mass and percentage fat were -0.06 ± 0.87 kg and -0.11% ± 1.97% for android and -0.04 ± 1.58 kg and -0.19% ± 4.27% for gynoid. Prediction values for fat mass and percentage fat were 94.6% and 88.9% for total body, 93.9% and 71.0% for trunk, and 92.4% and 64.1% for leg, respectively. The three-dimensional (3D) SBI produces reliable parameters that can predict android and gynoid as well as total and regional (trunk, leg) fat mass.

  15. DUOX 1 is induced in human thyroid cells submitted to X-Ray irradiation and is responsible for the bystander effect

    Energy Technology Data Exchange (ETDEWEB)

    Boufraqech, M.; Chevallier Lagente, O.; Weyemi, U.; Talbot, M.; Al Ghuzlan, A.; Courtin, F.; Bidart, J.M.; Schlumberger, M.; Dupuy, C. [UMR 8200 CNRS, Institut Gustave Roussy, Villejuit (France); Ameziane el Hassani, R. [UBRM, Centre National de l' Energie, des Sciences et des Techniques Nucleaires, Rabat (Morocco)

    2012-07-01

    Radiation-induced bystander effect is the mechanism by which cells that have not been directly exposed to ionizing radiation behave like exposed cells: they die or show chromosomal instability and other phenotypic abnormalities. Bystander cells may be either adjacent or at some distance from the exposed cells. Irradiated cells release soluble factors that can be transferred through cell culture medium to non-irradiated cells. These factors include cytokines and reactive oxygen species (ROS). The aim of this study was to identify the ROS generating system induced by X-ray irradiation of human thyroid cells that could be responsible for the bystander effect. Irradiation of human thyroid epithelial cells (HTori-3 cells) induced an extracellular production of H{sub 2}O{sub 2} after 4 days that was related to the radiation dose. Our study shows that radiation exposure increases DUOX-1 expression after several days, suggesting that this H{sub 2}O{sub 2} generating system could be responsible for the late bystander effect. This could have a potential importance for radiation risk assessment and for cancer radiotherapy

  16. How calibration and reference spectra affect the accuracy of absolute soft X-ray solar irradiance measured by the SDO/EVE/ESP during high solar activity

    Science.gov (United States)

    Didkovsky, Leonid; Wieman, Seth; Woods, Thomas

    2016-10-01

    The Extreme ultraviolet Spectrophotometer (ESP), one of the channels of SDO's Extreme ultraviolet Variability Experiment (EVE), measures solar irradiance in several EUV and soft x-ray (SXR) bands isolated using thin-film filters and a transmission diffraction grating, and includes a quad-diode detector positioned at the grating zeroth-order to observe in a wavelength band from about 0.1 to 7.0 nm. The quad diode signal also includes some contribution from shorter wavelength in the grating's first-order and the ratio of zeroth-order to first-order signal depends on both source geometry, and spectral distribution. For example, radiometric calibration of the ESP zeroth-order at the NIST SURF BL-2 with a near-parallel beam provides a different zeroth-to-first-order ratio than modeled for solar observations. The relative influence of "uncalibrated" first-order irradiance during solar observations is a function of the solar spectral irradiance and the locations of large Active Regions or solar flares. We discuss how the "uncalibrated" first-order "solar" component and the use of variable solar reference spectra affect determination of absolute SXR irradiance which currently may be significantly overestimated during high solar activity.

  17. Optical absorption of selenite single crystals subjected to high electric fields and irradiated with X-rays or γ-rays

    International Nuclear Information System (INIS)

    Mishra, Sakuntala; Rao, A.V.K.; Rao, K.V.

    1988-01-01

    Measurements of the optical absorption coefficient of selenite single crystals show two peaks at 236 and 400 nm when plotted as a function of wavelength. These peaks decrease with increasing irradiation time for both γ and X-rays. Subsequent thermal bleaching increases the absorption coefficient at all wavelengths and flattens out the peaks at 140 0 C and 330 0 C respectively. The imposition of an a.c. or d.c. field prior to irradiation preserves the thermal bleaching characteristics with an overall increase in absorption coefficient. These effects are attributed to two different types of bond formed by water of crystallization giving rise to the two absorption peaks. Irradiation may destroy some of the bands of loosely bound water molecules near defect regions leading to a decrease in absorption. Thermal bleaching removes water molecules reducing the transparency of the samples, the more strongly bound molecules being removed at the higher temperature. Irradiation after a.c. or d.c. field treatment may introduce more defect regions enabling the removal of more water molecules by bleaching and hence increasing the absorption. (U.K.)

  18. Nanoparticle-Assisted Scanning Focusing X-Ray Therapy with Needle Beam X Rays.

    Science.gov (United States)

    Davidson, R Andrew; Guo, Ting

    2016-01-01

    In this work, we show a new therapeutic approach using 40-120 keV X rays to deliver a radiation dose at the isocenter located many centimeters below the skin surface several hundred times greater than at the skin and how this dose enhancement can be augmented with nanomaterials to create several thousand-fold total dose enhancement effect. This novel approach employs a needle X-ray beam directed at the isocenter centimeters deep in the body while continuously scanning the beam to cover a large solid angle without overlapping at the skin. A Monte Carlo method was developed to simulate an X-ray dose delivered to the isocenter filled with X-ray absorbing and catalytic nanoparticles in a water phantom. An experimental apparatus consisting of a moving plastic phantom irradiated with a stationary 1 mm needle X-ray beam was built to test the theoretical predictions. X-ray films were used to characterize the dose profiles of the scanning X-ray apparatus. Through this work, it was determined that the X-ray dose delivered to the isocenter in a treatment voxel (t-voxel) underneath a 5 cm deep high-density polyethylene (HDPE) phantom was 295 ± 48 times greater than the surface dose. This measured value was in good agreement with the theoretical predicted value of 339-fold. Adding X-ray-absorbing nanoparticles, catalytic nanoparticles or both into the t-voxel can further augment the dose enhancement. For example, we predicted that adding 1 weight percentage (wp) of gold into water could increase the effective dose delivered to the target by onefold. Dose enhancement using 1 mm X-ray beam could reach about 1,600-fold in the t-voxel when 7.5 wp of 88 nm diameter silica-covered gold nanoparticles were added, which we showed in a previously published study can create a dose enhancement of 5.5 ± 0.46-fold without scanning focusing enhancement. Based on the experimental data from that study, mixing 0.02 wp 2.5 nm diameter small tetrakis hydroxymethyl phosphonium chloride (THPC

  19. Current levels of gonadal irradiation from a selection of routine diagnostic X-ray examinations in Great Britain

    International Nuclear Information System (INIS)

    Wall, B.F.; Fisher, E.S.; Shrimpton, P.C.; Rae, S.

    1980-07-01

    The gonadal doses from 13 types of diagnostic examination have been measured at 21 hospitals throughout the country in preparation for a new assessment of the genetically significant dose to the population of Great Britain from diagnostic radiology. Thermoluminescent dosemeters, consisting of lithium borate powder contained in adhesive polythene sachets, were used for the measurements. They were attached to patients to monitor the testes dose directly or the entrance skin dose at the level of the ovaries. Skin doses were converted to ovarian doses using factors obtained by measurements in an anthropomorphic phantom exposed to a range of typical diagnostic X-ray fields. The results indicate that for some types of examination there has been an increase and for others there has been a reduction in the mean gonadal dose delivered per examination since a similar survey was made 20 years ago. Individual gonadal doses for the same examination still ranged over 3 or 4 orders of magnitude throughout the country with distributions described by coefficients of variation that were no less than those found in the late 1950s. This large variability in patient exposure, together with the observation that examinations were satisfactorily conducted on children with a much higher degree of gonadal protection than that offered to young adults, indicates that many patients must be receiving doses that are unnecessarily high. (author)

  20. Nanoscale dose deposition in cell structures under X-ray irradiation treatment assisted with nanoparticles of a set of elements: an analytical approach to cell survival

    International Nuclear Information System (INIS)

    Melo B, W.; Barboza F, M.; Chernov, G.

    2016-10-01

    The goal of combining nanoparticles (Nps) with radiation therapy is to increase the differential effect between healthy and tumor tissues. Only some elements have been investigated to be used as radiosensitizers and no systematic experimental or theoretical comparisons between different materials have been developed. MacMahon, et al. (Nano scale, 2016, 8, 581) presents the first systematic computational study of the impact of elemental composition on nanoparticle radiation interaction for kilo voltage and megavoltage X-ray exposure, for a range of elements (Z = 14 - 80). In this study we present and analytical model to assess the cell survival modification responses of cell cultures under irradiation treatments with keV X-rays assisted with Nps of different materials as platinum, hafnium, gadolinium, gold, germanium, iodine and iron. This model starts from the data of radial dose deposition around a single 20 nm diameter Np irradiated with photons of an energy 20 keV higher than the element K-shell binding energy to the nano scale probability of dose distribution inside cell structures with embedded Nps (the assessment of the average dose and the average squared dose in cell structure). Also based on the Local Effect Model we estimate potential biological effects, as is the case of the Relative Biological Effectiveness (RBE). Nano scale dose deposition exhibits a complex dependence on atomic number, as a consequence of the variations in secondary Auger electron spectra, this is manifested in significant variations in RBE. Upon in vitro experiments RBE varies from 1 to 1.6. Values representative of a high radiosensitization were observed for lower energies, ones that are well reproduced by our analytical analysis for cell cultures with a homogeneous distribution of different material Nps. (Author)

  1. Nanoscale dose deposition in cell structures under X-ray irradiation treatment assisted with nanoparticles of a set of elements: an analytical approach to cell survival

    Energy Technology Data Exchange (ETDEWEB)

    Melo B, W.; Barboza F, M. [Universidad de Sonora, Departamento de Investigacion en Fisica, 83000 Hermosillo, Sonora (Mexico); Chernov, G., E-mail: g.chernovch@gmail.com [Universidad de Sonora, Departamento de Fisica, 83000 Hermosillo, Sonora (Mexico)

    2016-10-15

    The goal of combining nanoparticles (Nps) with radiation therapy is to increase the differential effect between healthy and tumor tissues. Only some elements have been investigated to be used as radiosensitizers and no systematic experimental or theoretical comparisons between different materials have been developed. MacMahon, et al. (Nano scale, 2016, 8, 581) presents the first systematic computational study of the impact of elemental composition on nanoparticle radiation interaction for kilo voltage and megavoltage X-ray exposure, for a range of elements (Z = 14 - 80). In this study we present and analytical model to assess the cell survival modification responses of cell cultures under irradiation treatments with keV X-rays assisted with Nps of different materials as platinum, hafnium, gadolinium, gold, germanium, iodine and iron. This model starts from the data of radial dose deposition around a single 20 nm diameter Np irradiated with photons of an energy 20 keV higher than the element K-shell binding energy to the nano scale probability of dose distribution inside cell structures with embedded Nps (the assessment of the average dose and the average squared dose in cell structure). Also based on the Local Effect Model we estimate potential biological effects, as is the case of the Relative Biological Effectiveness (RBE). Nano scale dose deposition exhibits a complex dependence on atomic number, as a consequence of the variations in secondary Auger electron spectra, this is manifested in significant variations in RBE. Upon in vitro experiments RBE varies from 1 to 1.6. Values representative of a high radiosensitization were observed for lower energies, ones that are well reproduced by our analytical analysis for cell cultures with a homogeneous distribution of different material Nps. (Author)

  2. Irradiation of gold nanoparticles by x-rays: Monte Carlo simulation of dose enhancements and the spatial properties of the secondary electrons production.

    Science.gov (United States)

    Leung, Michael K K; Chow, James C L; Chithrani, B Devika; Lee, Martin J G; Oms, Barbara; Jaffray, David A

    2011-02-01

    The aim of this study is to understand the characteristics of secondary electrons generated from the interaction of gold nanoparticles (GNPs) with x-rays as a function of nanoparticle size and beam energy and thereby further the understanding of GNP-enhanced radiotherapy. The effective range, deflection angle, dose deposition, energy, and interaction processes of electrons produced from the interaction of x-rays with a GNP were calculated by Monte Carlo simulations. The GEANT4 code was used to simulate and track electrons generated from a 2, 50, and 100 nm diameter GNP when it is irradiated with a 50 kVp, 250 kVp, cobalt-60, and 6 MV photon beam in water. When a GNP was present, depending on the beam energies used, secondary electron production was increased by 10- to 2000-fold compared to an absence of a GNP. Low-energy photon beams were much more efficient at interacting with the GNP by two to three orders of magnitude compared to MV energies and increased the deflection angle. GNPs with larger diameters also contributed more dose. The majority of the energy deposition was outside the GNP, rather than self-absorbed by the nanoparticle. The mean effective range of electron tracks for the beams tested ranged from approximately 3 microm to 1 mm. These simulated results yield important insights concerning the spatial distributions and elevated dose in GNP-enhanced radiotherapy. The authors conclude that the irradiation of GNP at lower photon energies will be more efficient for cell killing. This conclusion is consistent with published studies.

  3. Synchrotron soft X-ray imaging and fluorescence microscopy reveal novel features of asbestos body morphology and composition in human lung tissues

    Directory of Open Access Journals (Sweden)

    Polentarutti Maurizio

    2011-02-01

    Full Text Available Abstract Background Occupational or environmental exposure to asbestos fibres is associated with pleural and parenchymal lung diseases. A histopathologic hallmark of exposure to asbestos is the presence in lung parenchyma of the so-called asbestos bodies. They are the final product of biomineralization processes resulting in deposition of endogenous iron and organic matter (mainly proteins around the inhaled asbestos fibres. For shedding light on the formation mechanisms of asbestos bodies it is of fundamental importance to characterize at the same length scales not only their structural morphology and chemical composition but also to correlate them to the possible alterations in the local composition of the surrounding tissues. Here we report the first correlative morphological and chemical characterization of untreated paraffinated histological lung tissue samples with asbestos bodies by means of soft X-ray imaging and X-Ray Fluorescence (XRF microscopy, which reveals new features in the elemental lateral distribution. Results The X-ray absorption and phase contrast images and the simultaneously monitored XRF maps of tissue samples have revealed the location, distribution and elemental composition of asbestos bodies and associated nanometric structures. The observed specific morphology and differences in the local Si, Fe, O and Mg content provide distinct fingerprints characteristic for the core asbestos fibre and the ferruginous body. The highest Si content is found in the asbestos fibre, while the shell and ferruginous bodies are characterized by strongly increased content of Mg, Fe and O compared to the adjacent tissue. The XRF and SEM-EDX analyses of the extracted asbestos bodies confirmed an enhanced Mg deposition in the organic asbestos coating. Conclusions The present report demonstrates the potential of the advanced synchrotron-based X-ray imaging and microspectroscopy techniques for studying the response of the lung tissue to the

  4. Synchrotron soft X-ray imaging and fluorescence microscopy reveal novel features of asbestos body morphology and composition in human lung tissues.

    Science.gov (United States)

    Pascolo, Lorella; Gianoncelli, Alessandra; Kaulich, Burkhard; Rizzardi, Clara; Schneider, Manuela; Bottin, Cristina; Polentarutti, Maurizio; Kiskinova, Maya; Longoni, Antonio; Melato, Mauro

    2011-02-07

    Occupational or environmental exposure to asbestos fibres is associated with pleural and parenchymal lung diseases. A histopathologic hallmark of exposure to asbestos is the presence in lung parenchyma of the so-called asbestos bodies. They are the final product of biomineralization processes resulting in deposition of endogenous iron and organic matter (mainly proteins) around the inhaled asbestos fibres. For shedding light on the formation mechanisms of asbestos bodies it is of fundamental importance to characterize at the same length scales not only their structural morphology and chemical composition but also to correlate them to the possible alterations in the local composition of the surrounding tissues. Here we report the first correlative morphological and chemical characterization of untreated paraffinated histological lung tissue samples with asbestos bodies by means of soft X-ray imaging and X-Ray Fluorescence (XRF) microscopy, which reveals new features in the elemental lateral distribution. The X-ray absorption and phase contrast images and the simultaneously monitored XRF maps of tissue samples have revealed the location, distribution and elemental composition of asbestos bodies and associated nanometric structures. The observed specific morphology and differences in the local Si, Fe, O and Mg content provide distinct fingerprints characteristic for the core asbestos fibre and the ferruginous body. The highest Si content is found in the asbestos fibre, while the shell and ferruginous bodies are characterized by strongly increased content of Mg, Fe and O compared to the adjacent tissue. The XRF and SEM-EDX analyses of the extracted asbestos bodies confirmed an enhanced Mg deposition in the organic asbestos coating. The present report demonstrates the potential of the advanced synchrotron-based X-ray imaging and microspectroscopy techniques for studying the response of the lung tissue to the presence of asbestos fibres. The new results obtained by

  5. The combined effects of MRI and x-rays on ICR mouse embryos during organogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Yeunhwa; Hasegawa, Takeo; Yamamoto, Youichi [Suzuka Univ. of Medical Science, Mie (Japan); Kai, Michiaki; Kusama, Tomoko

    2001-09-01

    The combined effects of X-rays and magnetic resonance imaging (MRI) on mouse embryos at an early stage of organogenesis were investigated. Pregnant ICR mice were irradiated on day 8 of gestation with X-rays at a dose of 1 Gy and/or MRI at 0.5 T for 1 hour. The mortality rates of the embryos or fetuses, the incidence of external malformations, the fetal body weight and the sex ratio were observed at day 18 of gestation. A significant increase in embryonic mortality was observed after exposure to either 1 Gy of X-radiation or 0.5 T MRI. However, the combined X-rays and MRI did not show a statistically significant increase in embryonic mortality compared with the control. External malformations, such as exencephaly, a cleft palate and anophthalmia, were observed in mice irradiated with X-rays and/or MRI. The incidence of each malformation in all treated groups increased with statistical significance compared with the control mice. The incidence in mice irradiated with both X-rays and MRI was lower than in mice irradiated with only X-rays. The combined effects of the combination of radiation and MRI on the external malformations might be antagonistic. There were no statistically significant differences in fetal death, fetal body weight and sex ratio among all experimental groups. (author)

  6. The combined effects of MRI and x-rays on ICR mouse embryos during organogenesis

    International Nuclear Information System (INIS)

    Gu, Yeunhwa; Hasegawa, Takeo; Yamamoto, Youichi; Kai, Michiaki; Kusama, Tomoko

    2001-01-01

    The combined effects of X-rays and magnetic resonance imaging (MRI) on mouse embryos at an early stage of organogenesis were investigated. Pregnant ICR mice were irradiated on day 8 of gestation with X-rays at a dose of 1 Gy and/or MRI at 0.5 T for 1 hour. The mortality rates of the embryos or fetuses, the incidence of external malformations, the fetal body weight and the sex ratio were observed at day 18 of gestation. A significant increase in embryonic mortality was observed after exposure to either 1 Gy of X-radiation or 0.5 T MRI. However, the combined X-rays and MRI did not show a statistically significant increase in embryonic mortality compared with the control. External malformations, such as exencephaly, a cleft palate and anophthalmia, were observed in mice irradiated with X-rays and/or MRI. The incidence of each malformation in all treated groups increased with statistical significance compared with the control mice. The incidence in mice irradiated with both X-rays and MRI was lower than in mice irradiated with only X-rays. The combined effects of the combination of radiation and MRI on the external malformations might be antagonistic. There were no statistically significant differences in fetal death, fetal body weight and sex ratio among all experimental groups. (author)

  7. Change in fat-free mass assessed by bioelectrical impedance, total body potassium and dual energy X-ray absorptiometry during prolonged weight loss

    DEFF Research Database (Denmark)

    Hendel, H W; Gotfredsen, A; Højgaard, L

    1996-01-01

    A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK). These measu......A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK......). These measurements were compared with bioimpedance analysis (BIA) by applying 11 predictive BIA equations published in the literature. Predictive equations for the present study population were developed, with the use of fat-free mass (FFM) as assessed by TBK and DXA as references in multiple regression analysis....... The results of the BIA equations varied widely; FFM was generally overestimated by BIA as compared with DXA and TBK before and after weight loss. During weight loss, the FFM did not change, as estimated by DXA (1.3 +/- 2.3 kg, p > 0.05) and TBK (0.9 +/- 2.9 kg, p > 0.05). The recorded change in impedance (R...

  8. Change in fat-free mass assessed by bioelectrical impedance, total body potassium and dual energy X-ray absorptiometry during prolonged weight loss

    DEFF Research Database (Denmark)

    Hendel, H W; Gotfredsen, A; Højgaard, L

    1996-01-01

    A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK). These measu......A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK....... The results of the BIA equations varied widely; FFM was generally overestimated by BIA as compared with DXA and TBK before and after weight loss. During weight loss, the FFM did not change, as estimated by DXA (1.3 +/- 2.3 kg, p > 0.05) and TBK (0.9 +/- 2.9 kg, p > 0.05). The recorded change in impedance (R......) was also insignificant. Three BIA equations from the literature, which were not specific for the degree of obesity in the present study group, predicted changes in FFM (from 0.5 + 3.6 to 2.4 +/- 4.4kg, p > 0.05) that were comparable with those estimated by the reference methods. Eight equations from...

  9. Indus-2 X-ray lithography beamline for X-ray optics and material science applications

    Science.gov (United States)

    Dhamgaye, V. P.; Lodha, G. S.

    2014-04-01

    X-ray lithography is an ideal technique by which high aspect ratio and high spatial resolution micro/nano structures are fabricated using X-rays from synchrotron radiation source. The technique has been used for fabricating optics (X-ray, visible and infrared), sensors and actuators, fluidics and photonics. A beamline for X-ray lithography is operational on Indus-2. The beamline offers wide lithographic window from 1-40keV photon energy and wide beam for producing microstructures in polymers upto size ˜100mm × 100mm. X-ray exposures are possible in air, vacuum and He gas environment. The air based exposures enables the X-ray irradiation of resist for lithography and also irradiation of biological and liquid samples.

  10. Use of dual-energy X-ray absorptiometry in obese individuals: The possibility to estimate whole body composition from DXA half-body scans

    International Nuclear Information System (INIS)

    Lundqvist, K.; Neovius, M.; Grigorenko, A.; Nordenstroem, J.; Roessner, S.

    2009-01-01

    Background: Because of its high accuracy, dual-energy X-ray absorptiometry (DXA) has become one of the most frequently used methods for estimating human body composition. One limiting factor concerning measuring obese people with the DXA technique is the size of the scanning area. Objective: To explore the possibility of estimating whole body composition from half-body scans before and after weight reduction, and compare the results with densitometry measurements. Design: Intervention study of 15 obese adults (age 47.2 ± 13.4; BMI 35.9 ± 3.1) who were measured with full- and half-body DXA scans before and after a 7-week weight loss program. On both occasions, body composition was also assessed with air-displacement plethysmography (ADP). Results: The mean weight loss at follow-up was 14.9 ± 4.1 kg (5.0 kg/m 2 ), corresponding to a 14% decrease in body weight. When comparing the results from full- and half-body DXA, between 96% and 98% of the variance was explained. At baseline, %Body Fat (%BF) did not differ significantly between full and half-body measurements (0.6, -0.1-1.3), but the half-body method overestimated it by 1.0% (0.2-1.8) at follow-up. On the contrary, the difference between DXA and ADP in the assessment of %BF was both significant and of large magnitude (5.2; 2.4-8.0) at baseline, while non-significant and near zero (0.4; -1.3-2.2) at follow-up when the subjects had lost a significant amount of weight. Conclusion: The results obtained from half-body DXA scans can accurately predict whole body composition, as measured by full-body DXA, before and after significant weight reduction, in obese patients who barely fit into the scanning area. However, increasing discordance between DXA and ADP with increasing adiposity was seen, indicating that the measurements might not be as reliable on extreme obese subjects as on normal and overweight ditto

  11. Use of dual-energy X-ray absorptiometry in obese individuals: The possibility to estimate whole body composition from DXA half-body scans

    Energy Technology Data Exchange (ETDEWEB)

    Lundqvist, K. [Department of Molecular Medicine and Surgery, Karolinska Institutet, Karolinska University Hospital, SE-171 76 Stockholm (Sweden)], E-mail: kent.lundqvist@karolinska.se; Neovius, M. [Obesity Unit, Department of Medicine, Karolinska Institutet, Karolinska University Hospital, SE-141 86 Stockholm (Sweden); Grigorenko, A. [Research and Development Unit, YLab Wellcare Institute, SE-113 60 Stockholm (Sweden); Nordenstroem, J. [Department of Molecular Medicine and Surgery, Karolinska Institutet, Karolinska University Hospital, SE-171 76 Stockholm (Sweden); Roessner, S. [Obesity Unit, Department of Medicine, Karolinska Institutet, Karolinska University Hospital, SE-141 86 Stockholm (Sweden)

    2009-02-15

    Background: Because of its high accuracy, dual-energy X-ray absorptiometry (DXA) has become one of the most frequently used methods for estimating human body composition. One limiting factor concerning measuring obese people with the DXA technique is the size of the scanning area. Objective: To explore the possibility of estimating whole body composition from half-body scans before and after weight reduction, and compare the results with densitometry measurements. Design: Intervention study of 15 obese adults (age 47.2 {+-} 13.4; BMI 35.9 {+-} 3.1) who were measured with full- and half-body DXA scans before and after a 7-week weight loss program. On both occasions, body composition was also assessed with air-displacement plethysmography (ADP). Results: The mean weight loss at follow-up was 14.9 {+-} 4.1 kg (5.0 kg/m{sup 2}), corresponding to a 14% decrease in body weight. When comparing the results from full- and half-body DXA, between 96% and 98% of the variance was explained. At baseline, %Body Fat (%BF) did not differ significantly between full and half-body measurements (0.6, -0.1-1.3), but the half-body method overestimated it by 1.0% (0.2-1.8) at follow-up. On the contrary, the difference between DXA and ADP in the assessment of %BF was both significant and of large magnitude (5.2; 2.4-8.0) at baseline, while non-significant and near zero (0.4; -1.3-2.2) at follow-up when the subjects had lost a significant amount of weight. Conclusion: The results obtained from half-body DXA scans can accurately predict whole body composition, as measured by full-body DXA, before and after significant weight reduction, in obese patients who barely fit into the scanning area. However, increasing discordance between DXA and ADP with increasing adiposity was seen, indicating that the measurements might not be as reliable on extreme obese subjects as on normal and overweight ditto.

  12. Microstructural parameters in 8 MeV Electron irradiated Bombyx mori silk fibers by wide-angle X-ray scattering studies (WAXS)

    International Nuclear Information System (INIS)

    Halabhavi, Sangappa

    2009-01-01

    The present work looks into the microstructural modification in Bombyx mori silk fibers, induced by electron irradiation. The irradiation process was performed in air at room temperature by use of 8 MeV electron accelerators at different doses: 0, 25, 50, 75 and 100 kGy respectively. Irradiation of polymer can be used to crosslink or degrade the desired component or to fixate the polymer morphology. The changes in microstructural parameters in these natural polymer fibers have been studied using wide angle X-ray scattering (WAXS) method. The crystal imperfection parameters such as crystallite size , lattice strain (g in %) and enthalpy (a * ) have been determined by line profile analysis (LPA) using Fourier method of Warren. Exponential, Lognormal and Reinhold functions for the column length distributions have been used for the determination of these parameters. The goodness of the fit and the consistency of these results suggest that the exponential distribution gives much better results, even though lognormal distribution has been widely used to estimate the similar stacking faults in metal oxide compounds. (author)

  13. X-ray holography

    CERN Document Server

    Faigel, G; Belakhovsky, M; Marchesini, S; Bortel, G

    2003-01-01

    In the last decade holographic methods using hard X-rays were developed. They are able to resolve atomic distances, and can give the 3D arrangement of atoms around a selected element. Therefore, hard X-ray holography has potential applications in chemistry, biology and physics. In this article we give a general description of these methods and discuss the developments in the experimental technique. The capabilities of hard X-ray holography are demonstrated by examples.

  14. X-ray holography

    International Nuclear Information System (INIS)

    Faigel, G.; Tegze, M.; Belakhovsky, M.; Marchesini, S.; Bortel, G.

    2003-01-01

    In the last decade holographic methods using hard X-rays were developed. They are able to resolve atomic distances, and can give the 3D arrangement of atoms around a selected element. Therefore, hard X-ray holography has potential applications in chemistry, biology and physics. In this article we give a general description of these methods and discuss the developments in the experimental technique. The capabilities of hard X-ray holography are demonstrated by examples

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the table in the area of the body being imaged. When necessary, sandbags, pillows or other positioning devices will be used to help you ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) ... imaged receive minimal radiation exposure. top of page ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ... about radiology? Share your patient story here Images ... content. Related Articles and Media Radiation Dose in X-Ray and CT Exams ...

  17. Providing x-rays

    International Nuclear Information System (INIS)

    Mallozzi, P.J.; Epstein, H.M.

    1985-01-01

    This invention provides an apparatus for providing x-rays to an object that may be in an ordinary environment such as air at approximately atmospheric pressure. The apparatus comprises: means (typically a laser beam) for directing energy onto a target to produce x-rays of a selected spectrum and intensity at the target; a fluid-tight enclosure around the target; means for maintaining the pressure in the first enclosure substantially below atmospheric pressure; a fluid-tight second enclosure adjoining the first enclosure, the common wall portion having an opening large enough to permit x-rays to pass through but small enough to allow the pressure reducing means to evacuate gas from the first enclosure at least as fast as it enters through the opening; the second enclosure filled with a gas that is highly transparent to x-rays; the wall of the second enclosure to which the x-rays travel having a portion that is highly transparent to x-rays (usually a beryllium or plastic foil), so that the object to which the x-rays are to be provided may be located outside the second enclosure and adjacent thereto and thus receive the x-rays substantially unimpeded by air or other intervening matter. The apparatus is particularly suited to obtaining EXAFS (extended x-ray fine structure spectroscopy) data on a material

  18. Comparison of Dual Energy X-ray Absorptiometry and Bioimpedance in Assessing Body Composition and Nutrition in Peritoneal Dialysis Patients

    DEFF Research Database (Denmark)

    Popovic, Velena; Zerahn, Bo; Heaf, James Goya

    2017-01-01

    OBJECTIVE: Peritoneal dialysis (PD) patients are characterized by protein malnutrition and muscle wasting. Reliable, easy, and cheap methods for evaluating nutrition are desirable. Three methods are commonly available: dual-energy X-ray absorptiometry (DXA), bioimpedance (BI), and subjective global...... to LTI (BI) than LTI (DXA). Plasma albumin was correlated to LTI, FTI, and ICW/ht, and comorbidity to OH, clinical malnutrition, reduced FTI, but not LTI. CONCLUSION: Agreement between DXA and BI was high on a population basis but not at an individual level. Obesity and muscle wasting were common...

  19. Effect of x-ray irradiation upon the epithelial melanin unit of the hair bulb in hooded rat

    Energy Technology Data Exchange (ETDEWEB)

    Kostanecki, W.; Radwan, I.; Mroczkowski, T.

    1976-10-27

    A marked increase in the quantity of pigment in the upper bulb, penetration of melanosomes into the papillae and vacuolisation of the bulk keratinocytes occurred as early as 4 to 6 h after irradiation with a dose 600 to 1200 R. Afterwards considerable hyperpigmentations appeared in the proximal segments of dystrophic and catagen hairs and melanin was found in the catagen columns and beyond them. In most animals within 4 to 6 h after irradiation occurred a distinct vacuolisation of the Malpighian layer and the granular layer became more prominent.

  20. Comparison of the Lunar Prodigy and iDXA Dual-Energy X-ray Absorptiometers for Assessing Total and Regional Body Composition.

    Science.gov (United States)

    Morrison, Shannon A; Petri, Robert M; Hunter, Heather L; Raju, Dheeraj; Gower, Barbara

    2016-01-01

    The objective of the study was to assess the agreement of the Lunar Prodigy with the newer Lunar iDXA dual-energy X-ray absorptiometer for determining total body and regional (arms, legs, trunk) bone mineral density (BMD), bone mineral content (BMC), fat mass (FM), lean tissue mass (LTM), total body mass, and percent fat. Ninety-two healthy adult males (n = 36) and females (n = 56) were scanned consecutively on the iDXA and the Prodigy dual-energy X-ray absorptiometers. For iDXA, relative to Prodigy, paired t tests indicated significantly lower estimates for total body and regional BMD and BMC (p Prodigy for total body and regional BMD estimates (p Prodigy, investigators should be aware that certain total body and regional estimates are significantly different. The greatest percent differences were observed for arm BMD, FM, and percent fat. Copyright © 2016 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  1. Correlations Between Variations in Solar EUV and Soft X-Ray Irradiance and Photoelectron Energy Spectra Observed on Mars and Earth

    Science.gov (United States)

    Peterson, W. K.; Brain, D. A.; Mitchell, D. L.; Bailey, S. M.; Chamberlin, P. C.

    2013-01-01

    Solar extreme ultraviolet (EUV; 10-120 nm) and soft X-ray (XUV; 0-10 nm) radiation are major heat sources for the Mars thermosphere as well as the primary source of ionization that creates the ionosphere. In investigations of Mars thermospheric chemistry and dynamics, solar irradiance models are used to account for variations in this radiation. Because of limited proxies, irradiance models do a poor job of tracking the significant variations in irradiance intensity in the EUV and XUV ranges over solar rotation time scales when the Mars-Sun-Earth angle is large. Recent results from Earth observations show that variations in photoelectron energy spectra are useful monitors of EUV and XUV irradiance variability. Here we investigate photoelectron energy spectra observed by the Mars Global Surveyor (MGS) Electron Reflectometer (ER) and the FAST satellite during the interval in 2005 when Earth, Mars, and the Sun were aligned. The Earth photoelectron data in selected bands correlate well with calculations based on 1 nm resolution observations above 27 nm supplemented by broadband observations and a solar model in the 0-27 nm range. At Mars, we find that instrumental and orbital limitations to the identifications of photoelectron energy spectra in MGS/ER data preclude their use as a monitor of solar EUV and XUV variability. However, observations with higher temporal and energy resolution obtained at lower altitudes on Mars might allow the separation of the solar wind and ionospheric components of electron energy spectra so that they could be used as reliable monitors of variations in solar EUV and XUV irradiance than the time shifted, Earth-based, F(10.7) index currently used.

  2. Near edge x-ray spectroscopy theory

    International Nuclear Information System (INIS)

    1994-01-01

    We propose to develop a quantitative theory of x-ray spectroscopies in the near edge region, within about 100 eV of threshold. These spectroscopies include XAFS (X-ray absorption fine structure), photoelectron diffraction (PD), and diffraction anomalous fine structure (DAFS), all of which are important tools for structural studies using synchrotron radiation x-ray sources. Of primary importance in these studies are many-body effects, such as the photoelectron self-energy, and inelastic losses. A better understanding of these quantities is needed to obtain theories without adjustable parameters. We propose both analytical and numerical calculations, the latter based on our x-ray spectroscopy codes FEFF

  3. Investigations of the metabolism of NAD in embryonic neural tissue of mice after irradiation with X-rays

    International Nuclear Information System (INIS)

    Beuningen, M. van.

    1974-01-01

    Female mice of an institutes own inbred strain were killed on the 9th-13th day of pregnancy and the embryos were removed by caesarian section. The NAD content and protein content in the embryonic neural tissue of the mice increase the most from the 10th to 11th day. There is a relationship between NAD quantity and increase in size measured by the protein content. The enzymal activity of the NMN pyrophosphorylase runs parallel to the NAD rise and fall except for on the 11th day on which the enzyme increases further. The NAD biosynthesis from nicotinamide measured by the incorporation of 14-C nicotinamide in the NAD rises from the 10th to the 13th day. If one refers the incorporation to the protein content, however, the NAD synthesis falls from the 10th day onwards. An increase of the NAD content in the embryonic brain by the addition of nicotinamide in a high dose was not possible on the 10th and 12th day, whereas a clear increase was registered in the mother animal liver. Following an X-radiation with 200 R on the 9th day, the NAD content/brain dropped on the 11th day to its lowest point and had reached its normal value again on the 13th day, contrary to the protein content which only decreases on the 11th day. If one refers the NAD content, however, to protein quantity, then this only falls on the 10th day and rises on the 11th day almost to the normal value and has reached the latter by the 12th day. The NMN pyrophosphorylase activity falls on the 10th and 11th day, has its normal value on the 12th day and exceeds it on the 13th day. If one refers the enzyme activity to protein content, then it drops on the 10th day, reaches its lowest value on the 11th day, has its normal value on the 12th day and shoots above it on the 13th day. On the 10th day, the NAD content falls only after an X-ray with 200 R given on the 9th day, whereas the protein content remains constant. The NAD content does not change in the region of 50 to 150 R. (orig./LH) [de

  4. Verification of industrial x-ray machine: MINTs experience

    International Nuclear Information System (INIS)

    Aziz Amat; Saidi Rajab; Eesan Pasupathi; Saipo Bahari Abdul Ratan; Shaharudin Sayuti; Abd Nassir Ibrahim; Abd Razak Hamzah

    2005-01-01

    Radiation and electrical safety of the industrial x-ray equipment required to meet Atomic Energy Licensing Board(AELB) guidelines ( LEM/TEK/42 ) at the time of installation and subsequently a periodic verification should be ensured. The purpose of the guide is to explain the requirements employed in conducting the test on industrial x-ray apparatus and be certified in meeting with our local legislative and regulation. Verification is aimed to provide safety assurance information on electrical requirements and the minimum radiation exposure to the operator. This regulation is introduced on new models imported into the Malaysian market. Since June, 1997, Malaysian Institute for Nuclear Technology Research (MINT) has been approved by AELB to provide verification services to private company, government and corporate body throughout Malaysia. Early January 1997, AELB has made it mandatory that all x-ray equipment for industrial purpose (especially Industrial Radiography) must fulfill certain performance test based on the LEM/TEK/42 guidelines. MINT as the third party verification encourages user to improve maintenance of the equipment. MINT experiences in measuring the performance on intermittent and continuous duty rating single-phase industrial x-ray machine in the year 2004 indicated that all of irradiating apparatus tested pass the test and met the requirements of the guideline. From MINT record, 1997 to 2005 , three x-ray models did not meet the requirement and thus not allowed to be used unless the manufacturers willing to modify it to meet AELB requirement. This verification procedures on electrical and radiation safety on industrial x-ray has significantly improved the the maintenance cultures and safety awareness in the usage of x-ray apparatus in the industrial environment. (Author)

  5. The synergistic radiosensitizing effect of tirapazamine-conjugated gold nanoparticles on human hepatoma HepG2 cells under X-ray irradiation

    Directory of Open Access Journals (Sweden)

    Liu X

    2016-07-01

    Full Text Available Xi Liu,1–4 Yan Liu,1–4 Pengcheng Zhang,1–4 Xiaodong Jin,1–3 Xiaogang Zheng,1–4 Fei Ye,1–4 Weiqiang Chen,1–3 Qiang Li1–3 1Institute of Modern Physics, 2Key Laboratory of Heavy Ion Radiation Biology and Medicine, Chinese Academy of Sciences, 3Key Laboratory of Basic Research on Heavy Ion Radiation Application in Medicine, Gansu Province, Lanzhou, 4School of Life Science, University of Chinese Academy of Sciences, Beijing, People’s Republic of China Abstract: Reductive drug-functionalized gold nanoparticles (AuNPs have been proposed to enhance the damage of X-rays to cells through improving hydroxyl radical production by secondary electrons. In this work, polyethylene glycol-capped AuNPs were conjugated with tirapazamine (TPZ moiety, and then thioctyl TPZ (TPZs-modified AuNPs (TPZs-AuNPs were synthesized. The TPZs-AuNPs were characterized by transmission electron microscopy, ultraviolet-visible spectra, dynamic light scattering, and inductively coupled plasma mass spectrometry to have a size of 16.6±2.1 nm in diameter and a TPZs/AuNPs ratio of ~700:1. In contrast with PEGylated AuNPs, the as-synthesized TPZs-AuNPs exhibited 20% increment in hydroxyl radical production in water at 2.0 Gy, and 19% increase in sensitizer enhancement ratio at 10% survival fraction for human hepatoma HepG2 cells under X-ray irradiation. The production of reactive oxygen species in HepG2 cells exposed to X-rays in vitro demonstrated a synergistic radiosensitizing effect of AuNPs and TPZ moiety. Thus, the reductive drug-conjugated TPZs-AuNPs as a kind of AuNP radiosensitizer with low gold loading provide a new strategy for enhancing the efficacy of radiation therapy. Keywords: AuNPs, radiation enhancement, synergistic effect, human hepatoma cells, hydroxyl radical production

  6. Noninvasive measurements of body composition and body water via quantitative magnetic resonance, deuterium water, and dual-energy x-ray absorptiometry in awake and sedated dogs.

    Science.gov (United States)

    Zanghi, Brian M; Cupp, Carolyn J; Pan, Yuanlong; Tissot-Favre, Delphine G; Milgram, Norton W; Nagy, Tim R; Dobson, Howard

    2013-05-01

    To compare quantitative magnetic resonance (QMR), dual-energy x-ray absorptiometry (DXA), and deuterium oxide (D2O) methods for measurement of total body water (TBW), lean body mass (LBM), and fat mass (FM) in healthy dogs and to assess QMR accuracy. 58 Beagles (9 months to 11.5 years old). QMR scans were performed on awake dogs. A D2O tracer was administered (100 mg/kg, PO) immediately before dogs were sedated, which was followed by a second QMR or DXA scan. Jugular blood samples were collected before and 120 minutes after D2O administration. TBW, LBM, and FM determined via QMR were not significantly different between awake or sedated dogs, and means differed by only 2.0%, 2.2%, and 4.3%, respectively. Compared with results for D2O dilution, QMR significantly underestimated TBW (10.2%), LBM (13.4%), and FM (15.4%). Similarly, DXA underestimated LBM (7.3%) and FM (8.4%). A significant relationship was detected between FM measured via D2O dilution and QMR (r(2) > 0.89) or DXA (r(2) > 0.88). Even though means of TBW and LBM differed significantly between D2O dilution and QMR or DXA, values were highly related (r(2) > 0.92). QMR was useful for determining body composition in dogs and can be used to safely and rapidly acquire accurate data without the need for sedation or anesthesia. These benefits can facilitate frequent scans, particularly in geriatric, extremely young, or ill pets. Compared with the D2O dilution method, QMR correction equations provided accurate assessment over a range of body compositions.

  7. Is whole body bone mineral density measured by the dual energy X-ray absorptiometry applied to evaluate risk of osteoporosis among Japanese adult females?

    International Nuclear Information System (INIS)

    Sakai, Yumiko; Koike, George; Numata, Makoto; Taneda, Kiyoshi; Jingu, Sumie

    2010-01-01

    The purpose of this study is to measure whole body fat accurately, the dual energy X-ray absorptiometry (DXA) is widely utilized. Simultaneously, bone mineral density (BMD) of the whole body can also be measured. BMD is one of important information to diagnose osteoporosis. However, it is not established to use whole body BMD for this diagnosis. It is recommended that lumbar and/or hip BMD should be used for diagnosing osteoporosis by the guideline for prevention and treatment of osteoporosis. Although it is possible to measure whole body BMD and lumbar and/or hip BMD separately at the same visit, it is inevitable to expose patients to more X-ray. Therefore, an aim of this study is to elucidate the relationship between whole body BMD and lumbar BMD to find the cut off point of whole body BMD for screening of osteoporosis. Two hundred and thirty six Japanese adult females were ascertained to this study. Whole body BMD and lumbar BMD of each subject were measured with the use of Delphi W (Hologic, USA). One hundred and sixty five subjects were judged as possible osteoporosis (less than 80% of young adult mean (YAM) of lumbar BMD and/or definite fracture of lumbar vertebras). The cut off point of whole body BMD for screening possible osteoporosis was estimated by receiver operated characteristic (ROC) analysis. The cut off point of whole body BMD was 84% of YAM, equivalent to 80% of YAM of lumbar BMD, with the following sensitivity and specificity (0.84 and 0.79, respectively), indicating that whole body BMD could be used for screening osteoporosis. (author)

  8. Comparative study of radiation dose between digital panoramic X-ray unit and general panoramic X-ray unit

    International Nuclear Information System (INIS)

    Li Qingshan; Duan Tao; Wang Xiaoyun; Zhao Li; Dong Jian; Wei Lei

    2010-01-01

    Objective: To compare the actual dose of patients who receive the same medical practice by either digital panoramic X-ray unit and general panoramic X-ray unit and give evidence for better selection of oral X-ray examination method. Methods: Round sheet lithium fluoride (LiF) thermoluminescent dosimeters (TLD) were used. The experiment was divided into natural background contrast group, general panoramic X-ray children group, general panoramic X-ray adults group, digital panoramic X-ray children group and digital panoramic X-ray adults group. The dosimeter of natural background radiation was placed at the office of the doctor, the dosimeters of general panoramic X-ray children group and general panoramic X-ray adults group were irradiated by different conditions according to the clinical application of panoramic X-ray to children and adults, the dosimeters of digital panoramic X-ray children group and digital panoramic X-ray adults group were irradiated by different conditions according to the clinical application of digital panoramic X-ray to children and adults. The thermoluminescent dosimeter was used to count and calculate the exposure doses in various groups. Results: The dose of children exposed in general panoramic X-ray unit was 1.28 times of that in digital panoramic X-ray unit, there was significant difference (t=6.904, P<0.01). The dose of adults exposed in general panoramic X-ray unit was 1.55 times of that in the digital panoramic X-ray unit, there also was significant difference (t=-11.514. P< 0.01). Conclusion: The digital panoramic X-ray unit can reduce the dose of patients, so the digital panoramic X-ray unit should be used as far as possible. (authors)

  9. Evaluation of absorbed dose-distribution in the X-ray or gamma-irradiator for blood products

    International Nuclear Information System (INIS)

    Moriyama, Satoshi; Kurihara, Katsuhiko; Yokokawa, Nobuhiko; Satake, Masahiro; Juji, Takeo

    2001-01-01

    Irradiation of blood products abrogates the proliferation of lymphocytes present in cellular component, which is currently the only accepted methodology to prevent transfusion-associated graft versus host disease (TA-GVHD). A range of irradiation dose levels between 15 Gy and 50 Gy is being used, but the majority of facilities are employing 15 Gy. It should, however, be recognized that the delivered dose in the instrument canister might differ from the actual dose absorbed by the blood bag. This study have evaluated the actual dose distribution under practical conditions where a container was loaded with blood products or water bags, or filled with distilled water. This approach provides data that the maximum attenuation occurred when the container was completely filled with a blood-compatible material. Thus, an error of approximately 20 percent should be considered in the dose measured in the in-air condition. A dose calibration in an in-air condition may lead to substantial underexposure of the blood products. A dose distribution study using adequately prearranged exposure period verified that the absorbed dose of 15 Gy was attained at any point in the container for both linear accelerator and gamma-irradiator. The maximal difference in the absorbed dose between measured points was 1.5- and 1.6-fold for linear accelerator and gamma-irradiator, respectively. In conclusion, using blood-compatible materials, a careful dose calibration study should be employed in which the absorbed dose of 15 Gy is obtained at the point where the lowest dose could be expected. (author)

  10. Chest X-Ray

    Medline Plus

    Full Text Available ... loose, comfortable clothing. You may be asked to change into a gown. You may have some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a tiny ...

  11. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... d like to talk with you about chest radiography also known as chest x-rays. Chest x- ...

  12. X-ray generator for radiographs of seeds

    International Nuclear Information System (INIS)

    Suarez Canner, E.

    1996-01-01

    It is presented an X-ray generator which is destined to obtaining X-ray radiographs of seeds. It utilizes a low power X-ray tube with fine focal point. It consist of an electronic block and an irradiation chamber

  13. Mutational changes of intraspecific agressiveness in the convict cichlid (Cichlasoma nigrofasciatum Guenther) after irradiation of parental spermatogonia and oogonia with different doses of X-rays

    International Nuclear Information System (INIS)

    Juerges, U.; Schroeder, J.H.; Sund, M.

    1984-01-01

    The agonistic behavior of mated convict cichlids (Cichlasoma nigrofasciatum) derived from gonial germ cells which were exposed to 0 (controls), 250, 500, 1,000, or 2,000 R of X-rays was determined by counting the attacks delivered to subadult conspecifics during the first eight days after spawning. While no day effects and no interactions with sex and radiation dose were found, males were significantly more aggressive in the treatment groups than the corresponding females. The highest aggressivness appeared in F 1 pairs derived from parental gonia irradiated with 250 R, and the lowest aggressiveness occurred in the 500-F 1 group. These two treatment groups differed significantly from each other, whereas no further significant differences could be detected. F 1 males derived from gonial X-irradiation with 750 R could not be mated successfully because they killed their own females. The changes of male aggressiveness reflect reversely the previously published results of changes in social cohesiveness of the individual cichlid fish. (author)

  14. Trace analysis in the atmosphere, water bodies and uranium ores by means of X-ray fluorescence

    International Nuclear Information System (INIS)

    Perez Novara, A.M.

    1986-01-01

    Analysis with X-ray fluorescence is an instrumental method that evaluates concentrations, at trace levels, of elements in samples of all kinds. The applications of this method are broad, specially useful in the analysis of metals as contaminators in air and water, and as impurities in minerals. The preparation of the samples is very important to obtain good accuracy, and at the same time, you should make a series of standards of known concentrations so you can compare the counting of each sample against the standard, for each of the elements. You should make, depending on the nature of the sample, several corrections with respect to the background, interferences, overlaps, or for effects of a third element. (author)

  15. Effect of laser irradiation on root canal walls after final irrigation with 17% EDTA or BioPure MTAD: X-ray diffraction and SEM analysis.

    Science.gov (United States)

    Saghiri, Mohammed Ali; Asgar, Kamal; Gutmann, James L; Garcia-Godoy, Franklin; Ahmadi, Kamran; Karamifar, Kasra; Asatorian, Armen

    2012-01-01

    To evaluate the effect of diode laser irradiation on crystallographic and morphologic characteristics of root canal walls after final irrigation with either 17% EDTA or BioPure MTAD. Root canals in 60 single-rooted teeth were instrumented using a rotary Ni-Ti system. The teeth were randomly divided into three groups (n = 20) based on the final irrigants: group 1, saline; group 2, 17% EDTA; and group 3, MTAD. Each group was further divided into two subgroups (n = 10). Subgroup A received diode laser irradiation at a wavelength of 810 nm and an output power of 2 W for 5 × 5 seconds, while subgroup B received no irradiation. A paired t test was used to compare mean dentinal erosion before and after irradiation in each group. Specimens were analyzed using SEM and x-ray diffractometery. One-way ANOVA and a post hoc Tukey test were used to evaluate dentinal erosion between groups. Kruskal-Wallis and Mann-Whitney U tests were used to evaluate any significant differences in the amount of dentin erosion between the groups. SEM micrographs showed closed dentinal tubules in the control group, while in unlased BioPure MTAD and EDTA groups, clean root canal walls were evident. Erosion was mostly seen in EDTA-treated teeth, while an increase of erosion degree was noted on root canal walls after additional laser irradiations. After irrigation and laser irradiation, the XRD spectrums indicated sharper peaks of EDTA, which showed a slight crystallographic change compared with the other groups. EDTA made changes in the mineralization of dentin due to its higher accumulation on the dentinal wall surface and produced significant degrees of erosion in comparison with MTAD by changing the physical properties of the root canal wall surface. These undesirable changes can be enhanced by further laser irradiation. Results confirm that a diode laser in combination with BioPure MTAD have minimum effect on the chemical properties of root canal dentin while having good smear layer removal

  16. Radiation therapy for angiosarcoma of the scalp: treatment outcomes of total scalp irradiation with X-rays and electrons.

    Science.gov (United States)

    Hata, Masaharu; Wada, Hidefumi; Ogino, Ichiro; Omura, Motoko; Koike, Izumi; Tayama, Yoshibumi; Odagiri, Kazumasa; Kasuya, Takeo; Inoue, Tomio

    2014-10-01

    Wide surgical excision is the standard treatment for angiosarcoma of the scalp, but many patients are inoperable. Therefore, we investigated the outcome of radiation therapy for angiosarcoma of the scalp. Seventeen patients with angiosarcoma of the scalp underwent radiation therapy with total scalp irradiation. Four patients had cervical lymph node metastases, but none had distant metastases. A median initial dose of 50 Gy in 25 fractions was delivered to the entire scalp. Subsequently, local radiation boost to the tumor sites achieved a median total dose of 70 Gy in 35 fractions. Fourteen of the 17 patients developed recurrences during the median follow-up period of 14 months after radiation therapy; 7 had recurrences in the scalp, including primary tumor progression in 2 patients and new disease in 5, and 12 patients developed distant metastases. The primary progression-free, scalp relapse-free, and distant metastasis-free rates were 86, 67, and 38 % at 1 year and 86, 38, and 16 % at 3 years, respectively. Thirteen patients died; the overall and cause-specific survival rates were both 73 % at 1 year and 23 and 44 % at 3 years, respectively. The median survival time was 16 months. There were no therapy-related toxicities ≥ grade 3. Total scalp irradiation is safe and effective for local tumor control, but a dose of ≤ 50 Gy in conventional fractions may be insufficient to eradicate microscopic tumors. For gross tumors, a total dose of 70 Gy, and > 70 Gy for tumors with deep invasion, is recommended.

  17. X-ray tubes for computed tomography

    International Nuclear Information System (INIS)

    Kotabe, Munenori; Sado, Noriyuki; Tachiki, Shigeru; Kitsuya, Minoru

    1979-01-01

    The X-ray tomography by computer processing (CT) is rapidly spreading because of the capabilities to obtain useful diagnostic information quantitatively, which was not able to be obtained by conventional X-ray photography, and to perform no-intrusion inspection, because it can picture the difference of X-ray absorption coefficient of several per cent in the soft tissues inside craniums. As the X-ray tubes to meet these requirements, the fixed anode X-ray tubes having high continuous rating are required for head CT, while the rotary anode X-ray tubes having the large cumulative heat capacity of anodes for whole body CT. Hitachi Ltd. has developed the X-ray tubes of type H 7129 of 4 kW rating for head CT and of type UJ-6FC-05V of 300 kHU (heat unit) for whole body CT. The specifications required for respective X-ray tubes include several items, and the maximum working tube voltage, focusing dimensions, long or short term maximum input and others are reported for the above described tubes. The performance centering around the loading life-time is described. In the tubes for whole body CT, repeated loading is also investigated. For the assumed input of 70,000 HU/slice, repeated loading of 10 times or more is possible in both cases when the input is repeatedly applied at loading intervals of 90 and 120 sec. (Wakatsuki, Y.)