WorldWideScience

Sample records for blood-pool spect comparison

  1. Two dimensional polar display of cardiac blood pool SPECT

    International Nuclear Information System (INIS)

    Honda, Norinari; Machida, Kikuo; Mamiya, Toshio; Takahashi, Taku; Takishima, Teruo; Hasegawa, Noriko; Hashimoto, Masanori; Ohno, Ken

    1989-01-01

    A new method of ECG gated cardiac blood pool SPECT to illustrate the left ventricular (LV) wall motion in a single static image, two dimensional polar display (2DPD), was described. Circumferential profiles of the difference between end diastolic and end systolic short axis images of the LV were displayed in a similar way to the bull's eye plot of 201 Tl myocardial SPECT. The diagnoses by 2DPDs agreed with those by cinematic displays of ECG gated blood pool SPECT in 74 out of 84 segments (85.5%) of abnormal motion, and 155 out of 168 segments (80.3%) of normal motion. It is concluded that 2DPD can evaluate regional wall motion by a single static image in a significant number of patients, and is also useful in comparing with the bull's eye image of 201 Tl myorcardial SPECT. (orig.)

  2. A Giant Hepatic Hemangioma Complicated by Kasabach-Merritt Syndrome: Findings of Tc-99m RBC Scintigraphy and SPECT Including a Total Body Blood Pool Imaging Study

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Myung Hee; Jeong, Hwan Jeong; Lim, Seok Tae; Kim, Dong Wook; Yim, Chang Yeol [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2009-02-15

    Kasabach-Merritt syndrome (KMS) consists of thrombocytopenia, microangiopathic hemolytic anemia, and localized consumption coagulopathy that develops within vascular hemangioma. This syndrome may also be associated with occult hemangiomas located at various sites. Tc-99m RBC scintigraphy and SPECT have proven to be reliable for confirming or excluding hemangioma. Total body blood pool imaging study during the scintigraphy also provides a means of screening for occult lesions. The authors report the case of a 29-year-old man who presented with a giant hepatic hemangioma complicated by KMS, and underwent Tc-99m RBC scintigraphy and SPECT including a total body blood pool imaging study.

  3. Methods of gated-blood-pool-spect data processing

    International Nuclear Information System (INIS)

    Kosa, I.; Mester, J.; Tanaka, M.; Csernay, L.; Mate, E.; Szasz, K.

    1991-01-01

    Three techniques of gated SPECT were evaluated. The methods of Integral SPECT (ISPECT), enddyastole-endsystole SPECT (ED-ES SPECT) and Fourier SPECT were adapted and developed on the Hungarian nuclear medicine data processing system microSEGAMS. The methods are based on data reduction before back projection which results in processing times acceptable for the clinical routine. The clinical performance of the introduced techniques was tested in 10 patients with old posterior myocardial infarction and in 5 patients without cardiac disease. The left ventricular ejection faction determined by ISPECT correlated well with the planar values. The correlation coefficient was 0.89. The correlation coefficient of EF values determined by ED-ES SPECT and planar radionuclide ventriculography was lower (0.70). For the identification of left ventricular wall motion abnormalities ED-ES SPECT and Fourier SPECT exhibited a favourable performance, but ISPECT only moderate suitability. In the detection of regional phase delay Fourier-SPECT demonstrated higher sensitivity than the planar radionuclide ventriculography. (author) 4 refs.; 3 figs.; 2 tabs

  4. Comparison of left ventricular ejection fraction by 201Tl gated SPECT and gated blood pool scan

    International Nuclear Information System (INIS)

    Lau, W.F.E.; Kelly, M.J.; O'Donnell, M.; Kalff, V.; Van Every, B.

    2000-01-01

    Full text: The aim of this study was to evaluate left ventricular ejection fraction (LVEF) determination by the Germano 201 Tl gated-SPECT myocardial perfusion (TLGSMP) method using gated blood pool scintigraphy (GBPS) as a reference. 21 patients underwent both TLGSMP and GBPS within eight days of each other from June 1997 to Jan 2000. Acquisition of TLGSMP was performed on a GE Optima NX dual head camera using Tl-201 dose of 1.5MBq/Kg and imaging time of 45 cardiac cycles/step with 16 steps/90 Deg of rotation per detector. All LVEF results were determined using a GE Genie workstation. GBPS results were compared with TLGSMP results for LVEF obtained from the reinjection images using automated Germano processing, and from the stress images using automatic and manual processing. Duplicate automatic analysis by a second observer produced identical mean TLGSMP LVEF results (r = 0.99). Stress TLGSMP LVEF by the automatic and manual processing correlate well (r = 0.99) but the manual LVEF is significantly lower. In conclusion LVEF determination using TLGSMP is highly reproducible and is also accurate when applied to reinjection data. Both manual processing and the use of stress data lead to underestimation of LVEF. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  5. Assessment of left ventricular function by gated myocardial perfusion and gated blood-pool SPECT. Can we use the same reference database?

    Energy Technology Data Exchange (ETDEWEB)

    Paul, A.K.; Hasegawa, Shinji; Yoshioka, Jun; Yamaguchi, Hitoshi; Tsujimura, Eiichiro; Nishimura, Tsunehiko [Osaka Univ., Suita (Japan). Graduate School of Medicine

    2000-04-01

    The purpose of this study was to compare left ventricular (LV) volume and ejection fraction (LVEF) measurements obtained with electrocardiographic gated single-photon emission computed tomographic (SPECT) myocardial perfusion imaging (GS-MPI) with those obtained with gated SPECT cardiac blood-pool imaging (GS-pool). Fifteen patients underwent GS-MPI with technetium-99m tetrofosmin and GS-pool with technetium-99m-erythrocyte, within a mean interval of 8{+-}3 days. Eight patients had suspected dilated cardiomyopathy and seven patients had angiographically significant coronary artery disease. End-diastolic volume (EDV), end-systolic volume (ESV) and LVEF measurements were estimated from GS-MPI images by means of Cedars-Sinai automatic quantitative program and from GS-pool images by the threshold technique. Mean differences between GS-MPI and GS-pool in EDV, ESV and LVEF measurements were -2.8{+-}10.5 ml [95% confidence interval (CI): -8.6{+-}3.0 ml], 2.6{+-}7.3 ml (CI: -1.4-6.6 ml) and -2.3{+-}5.1% (CI: -5.1-0.6%), respectively. No significant difference in the mean differences from 0 was found for EDV, ESV or LVEF measurements. Bland-Altman plots revealed no trend over the measured LV volumes and LVEF. For all parameters, regression lines approximated lines of identity. The excellent agreement between GS-MPI and GS-pool measurements suggests that, for estimation of LV volumes and LVEF, these two techniques may be used interchangeably and measurements by one method can serve as a reference for the other. (author)

  6. Evaluation of hepatic hemangioma by Tc-99 m red blood cell hepatic blood pool scan

    International Nuclear Information System (INIS)

    Sohn, Myung Hee

    2005-01-01

    Hemangioma is the most common benign tumor of the liver, with a prevalence estimated as high as 7%. Tc-99m red blood cell (RBC) hepatic blood pool scan with single photon emission computed tomography (SPECT) imaging is extremely useful for the confirmation or exclusion of hepatic hemangiomas. The classic finding of absent or decreased perfusion and increased blood pooling ('perfusion/blood pool mismatch') is the key diagnostic element in the diagnosis of hemangiomas. The combination of early arterial flow and delayed blood pooling ('perfusion/blood pool match') is shown uncommonly. In giant hemangioma, filling with radioactivity appears first in the periphery, with progressive central fill-in on sequential RBC blood pool scan. However, the reverse filling pattern, which begins first in the center with progressive peripheral filling, is also rarely seen. Studies with false-positive blood pooling have been reported infrequently in nonhemangiomas, including hemangiosarcoma, hepatocellular carcinoma, hepatic adenoma, and metastatic carcinomas (adenocarcinma of the colon, small cell carcinoma of the lung, neruroendocrine carcinoma). False-negative results have been also reported rarely except for small hemagniomas that are below the limits of spatial resolution of gamma camera

  7. Assessment of left ventricular function by gated cardiac blood-pool emission computed tomography using a rotating gamma camera

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Honda, Minoru

    1991-01-01

    To elucidate the usefulness of gated cardiac blood-pool single photon emission CT (SPECT) with Tc-99m for the evaluation of left ventricular (LV) global and regional functions, 18 patients with coronary artery disease were studied. Thirty-two gated projection images were obtained over 360-degree at 16 frames per cardiac cycle. As LV volume was calculated by integrating the numbers of voxels which constituted LV and multiplying by the volume of a single voxel (0.1143 ml), we performed phantom studies to determine the appropriate cut-off level to detect LV outline. These cut-off levels were affected by the background activity and organ volume itself. So we constructed Volume-Cut-Level-Curve at each background activity. In clinical studies, short axis images which constituted LV were selected and provisional LV volumes were calculated at the cut-off levels of 45, 50 and 55%. These volumes were plotted on the Volume-Cut-Level-Curve and the true cut-off levels were obtained to calculate LV end-diastolic or end-systolic volume (EDV, ESV). The cut-off levels were different at every patient and ED or ES. EDV, ESV and LV ejection fraction obtained by SPECT were correlatd well with those obtained by contrast ventriculography (LVG) (r=0.89, 0.94, 0.94 each, p<0.01). For the LV wall motion analysis, LVGs obtained at two projections were compared with SPECT or gated cardiac blood-pool planar imaging (Planar) in 5 segments. In addition to visual comparison, wall motion scores (WMS) based on the degree of wall motion abnormality were calculated in each segment. Correlation of WMS between LVG and SPECT (r=0.84) was significantly (p<0.01) superior to that between LVG and Planar (r=0.62). Especially in SPECT, wall motion analyses at septal and infero-posterior segments were superior to those in Planar. Although gated SPECT requires relatively long time to perform, it is a useful method to detect LV global and regional functions. (author)

  8. Comparison of gated blood pool SPECT and spiral multidetector computed tomography in the assessment of right ventricular functional parameters. Validation with first-pass radionuclide angiography

    International Nuclear Information System (INIS)

    Lee, Jung S.; Kim, Seong-Jang; Kim, In-Ju; Kim, Yong-Ki; Choo, Ki S.; Lee, Jun S.

    2007-01-01

    The aim of this study was to compare gated blood pool single photon emission computed tomography (SPECT) (GBPS) and multidetector row computed tomography (MDCT) for the determination of right ventricular ejection fraction (RVEF) and right ventricular volumes (RVV) and to compare first-pass radionuclide angiography (FP-RNA) as the gold standard. Twenty consecutive patients (11 men, 9 women) referred for MDCT for the evaluation of the presence of coronary artery disease underwent FP-RNA and GBPS. The mean right ventricular end-diastolic volume (EDV) calculated with GBPS revealed a statistically significant lower value than that of MDCT. The mean right ventricular end-systolic volume (ESV) calculated with GBPS was also lower than that of MDCT. A comparison of right ventricular EDV from GBPS and MDCT yielded a correlation coefficient of 0.5972. Right ventricular ESV between GBPS and MDCT showed a correlation coefficient of 0.5650. The mean RVEFs calculated with FP-RNA (39.8%±4.0%), GBPS (43.7%±6.9%), and MDCT (40.4%±7.7%) showed no statistical differences (Kruskal-Wallis statistics 4.538, P=0.1034). A comparison of RVEFs from FP-RNA and GBPS yielded a correlation coefficient of 0.7251; RVEFs between FP-RNA and MDCT showed a correlation coefficient of 0.6166 and between GBPS and MDCT showed a correlation coefficient of 0.6367. The RVEF, EDV, and ESV calculated by GBPS had good correlation with those obtained with MDCT. In addition, there were no statistical differences of RVEF calculated from FP-RNA, GBPS, and MDCT. However, with regard to RVV, EDV and ESV from GBPS revealed statistically significantly lower values than those of MDCT. Although reasonable correlations among these modalities were obtained, the agreement among these three modalities was not good enough for interchangeable use in the clinical setting. Also, these results should be confirmed in patients with cardiac diseases in future larger population-based studies. (author)

  9. Clinical evaluation of the Tl-201 ECG-gated myocardial SPECT

    International Nuclear Information System (INIS)

    Mochizuki, Teruhito

    1989-01-01

    In order to evaluate the clinical usefulness of the Tl-201 ECG-gated myocardial single photon emission computed tomography (SPECT), we compared the wall motion and the grade of the Tl-201 uptake of the ECG-gated myocardial SPECT with the wall motion of the ECG-gated blood pool SPECT. Materials were 87 patients of 50 old myocardial infarctions (OMIs), 19 hypertrophic cardiomyopathies (HCMs), 2 dilated cardiomyopathies (DCMs) and 16 others. After intravenous injection of 111-185 MBq (3-5 mCi) of Tl-201 at rest, the projection data were acquired using a rotating gamma-camera through 180deg, from RAO 45deg in 24 directions, each of which consisted of 80-100 beats. For the reconstruction of ED, ES and non-gated images, R-R interval was divided into about 20 (18-22) fractions. In 348 regions of interest (anterior, septal, lateral and inferior wall) in 87 cases, wall motion and the Tl-201 uptake were evaluated to three grades (normal, hypokinesis and akinesis; normal, low and defect, respectively), which were compared with the wall motion of the ECG-gated blood pool SPECT. The wall motion and the grade of the Tl-201 uptake of the ECG-gated myocardial SPECT correlated well with the wall motion of the ECG-gated blood pool SPECT (96.6% and 87.9%, respectively). In conclusion, the ECG-gated myocardial SPECT can provide clear perfusion images and is a very useful diagnostic strategy to evaluate the regional wall motion and perfusion simultaneously. (author)

  10. Technetium-99m-labelled red blood cell imaging in the diagnosis of hepatic haemangiomas: the role of SPECT/CT with a hybrid camera

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, Orazio; Danieli, Roberta; Manni, Carlo; Capoccetti, Francesca; Simonetti, Giovanni [Department of Biopathology and Diagnostic Imaging, University ' ' Tor Vergata' ' , Rome (Italy)

    2004-07-01

    Delayed liver single-photon emission computed tomography (SPECT) after {sup 99m}Tc red blood cell (RBC) labelling is helpful in detecting hepatic haemangiomas; however, diagnosis can be difficult when lesions are situated adjacent to structures like the inferior vena cava, the heart or hepatic vessels, where blood activity persists. The aims of this study were to evaluate the usefulness of RBC SPECT and transmission computed tomography (RBC SPECT/CT) performed simultaneously with a hybrid imaging system for correct characterisation of hepatic lesions in patients with suspected haemangioma, and to assess the additional value of fused images compared with SPECT alone. Twelve patients with 24 liver lesions were studied. The acquisitions of both anatomical (CT) and functional (SPECT) data were performed during a single session. SPECT images were first interpreted alone and then re-evaluated after adding the transmission anatomical maps. Image fusion was successful in all patients, with perfect correspondence between SPECT and CT data, allowing the precise anatomical localisation of sites of increased blood pool activity. SPECT/CT had a significant impact on results in four patients (33.3%) with four lesions defined as indeterminate on SPECT images, accurately characterising the hot spot foci located near vascular structures. In conclusion, RBC SPECT/CT imaging using this hybrid SPECT/CT system is feasible and useful in the identification or exclusion of suspected hepatic haemangiomas located near regions with high vascular activity. (orig.)

  11. Cerebral blood flow measurement using 123I-IMP graph plot method with SPECT. Comparison with autoradiography method

    International Nuclear Information System (INIS)

    Shinohara, Yuki; Kamitani, Hideki; Ishibashi, Minako; Ito, Satoru; Ogawa, Toshihide

    2011-01-01

    The purpose of this study was to evaluate quantification of cerebral blood flow (CBF) values using 123 I-iodoamphetamine (IMP) graph plot (GP) method with single photon emission computed tomography (SPECT), compared with autoradiography (ARG) method. IMP-SPECT by GP combined with ARG method at rest was performed in 40 patients to determine the equation of linear regression for GP method in our institution. In addition, we compared regional CBF (rCBF) values at rest between GP and ARG methods in 10 other patients. Among all 50 patients, acetazolamide (ACZ)-challenged SPECT by GP combined with ARG method using 2-day protocol was performed in 10 patients. We also compared the rCBF values after ACZ challenge between GP and ARG methods in these 10 patients. The equation of linear regression for GP method in our institution was y=1.945x+20.36 (R 2 =0.586, P 2 =0.624, P 2 =0.150, P<0.001). IMP-SPECT by GP method at rest is useful to measure reliable rCBF values without arterial blood sampling, although we need pay attention to interpret the result of 2-day protocol ACZ-challenged SPECT by GP method. (author)

  12. Left ventricular ejection fraction determined by gated Tl-201 perfusion SPECT and quantitative software

    International Nuclear Information System (INIS)

    Hyun, In Young; Kim, Sung Eun; Seo, Jeong Kee; Hong, Eui Soo; Kwan, Jun; Park, Keum Soo; Lee, Woo Hyung

    2000-01-01

    We compared estimates of ejection fraction (EF) determined by gated Tl-201 perfusion SPECT (g-Tl-SPECT) with those by gated blood pool (GBP) scan. Eighteen subjects underwent g-Tl-SPECT and GBP scan. After reconstruction of g-Tl-SPECT, we measured EF with Cedars software. The comparison of the EF with g-Tl-SPECT and GBP scan was assessed by correlation analysis and Bland Altman plot. The estimates of EF were significantly different (p<0.05) with g-Tl-SPECT (40%±14%) and GBP scan (43%±14%). There was an excellent correlation of EF between g-Tl-SPECT and GBP scan (r=3D0.94, p<0.001). The mean difference of EF between GBP scan and g-Tl-SPECT was +3.2%. Ninety-five percent limits of agreement were ±9.8%. EF between g-Tl-SPECT and GBP scan were in poor agreement. The estimates of EF by g-Tl-SPECT was well correlated with those by GBP scan. However, EF of g-Tl-SPECT doesn't agree with EF of GBP scan. EF of g-Tl-SPECT can't be used interchangeably with EF of GBP scan.=20

  13. A comparison of positron-emitting blood pool imaging agents

    International Nuclear Information System (INIS)

    Hnatowich, D.J.; Kulprathipanja, S.; Evans, G.; Elmaleh, D.

    1979-01-01

    The three agents, 11 C-carboxyhaemoglobin, 68 Ga-transferrin and 68 Ga-labelled red cells have been compared in dogs to assess their relative merits for blood-pool imaging. For 1 h following administration of each agent, periodic blood samples were withdrawn for counting in a NaI (Tl) well counter while conventional two-dimensional images were obtained simultaneously on the Massachusetts General Hospital positron camera. Count rates in regions about the heart, liver and spleen were obtained for each image. The disappearance of blood activity as shown from the results of counting the blood samples and from the counting rates in regions about the heart was found to be identical within experimental error for the three agents. In the liver and spleen regions, the highest count rates were obtained with 68 Ga-transferrin and the lowest with 68 Ga-labelled red cells; count rates in these regions with labelled red cells were virtually constant throughout the 1 h study. It may be concluded that with the exceptions noted above, the three agents are approximately equivalent for blood-pool imaging. (author)

  14. SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits.

    Science.gov (United States)

    Chen, Lung-Ching; Lin, Chih-Yuan; Chen, Ing-Jou; Ku, Chi-Tai; Chen, Yen-Kung; Hsu, Bailing

    2016-01-01

    Recently, myocardial blood flow quantitation with dynamic SPECT/CT has been reported to enhance the detection of coronary artery disease in human. This advance has created important clinical applications to coronary artery disease diagnosis and management for areas where myocardial perfusion PET tracers are not available. We present 2 clinical cases that undergone a combined test of 1-day rest/dipyridamole-stress dynamic SPECT and ECG-gated myocardial perfusion SPECT scans using an integrated imaging protocol and demonstrate that flow parameters are capable to conclude equivocal myocardial perfusion SPECT studies, therefore increasing diagnostic benefits to add value in making clinical decisions.

  15. Evaluation of latent cardiac disease in diabetic patients with Tl-201 exercise myocardial scintigram and blood pool scintigram

    International Nuclear Information System (INIS)

    Miyashita, Takeo; Kasai, Ryutaro; Ikebe, Nobuhiko; Nagai, Yoshikazu; Yamasawa, Ikuhiro; Ibukiyama, Chiharu; Notoya, Yoko

    1990-01-01

    To find latent heart disease in diabetic patients, 142 diabetic patients were divided into 4 groups: (1) no hypertension and normal ECG (DM group); (2) hypertension recognized clinically (HT group); (3) myocardial damage on ECG (MD group); (4) group associated with the previous 2 (HT+MD group). In all groups Tl-201 exercise myocardial scintigrams and blood pool scintigrams were taken for comparative analysis. Positive rates of SPECT were 27.7% (23/83) in the DM group, 30.0% (9/30) in the HT group, 50.0% (6/12) in the MD group, and 70.6% (12/17) in the HT+MD group. The rate in the HT+MD group was significantly higher than in that of the DM and HT groups (p<0.001, p<0.01). Blood pool scintigrams revealed that in the HT+MD group, as compared with the normal control group, both 1/3 FF and PFR were significantly depressed, in addition to significant TPF prolongation in the former (p<0.001, p<0.05, p<0.05). These findings suggest that in diabetic patients hypertension and myocardial damage would lead to a high incidence of abnormality in SPECT and left ventricular rapid filling dysfunction. This indicate a high incidence of latent cardiac disease which can be recognized in diabetic patients by stress myocardial and blood pool scintigrams. (author)

  16. Development and optimization of SPECT gated blood pool cluster analysis for the prediction of CRT outcome

    Energy Technology Data Exchange (ETDEWEB)

    Lalonde, Michel, E-mail: mlalonde15@rogers.com; Wassenaar, Richard [Department of Physics, Carleton University, Ottawa, Ontario K1S 5B6 (Canada); Wells, R. Glenn; Birnie, David; Ruddy, Terrence D. [Division of Cardiology, University of Ottawa Heart Institute, Ottawa, Ontario K1Y 4W7 (Canada)

    2014-07-15

    Purpose: Phase analysis of single photon emission computed tomography (SPECT) radionuclide angiography (RNA) has been investigated for its potential to predict the outcome of cardiac resynchronization therapy (CRT). However, phase analysis may be limited in its potential at predicting CRT outcome as valuable information may be lost by assuming that time-activity curves (TAC) follow a simple sinusoidal shape. A new method, cluster analysis, is proposed which directly evaluates the TACs and may lead to a better understanding of dyssynchrony patterns and CRT outcome. Cluster analysis algorithms were developed and optimized to maximize their ability to predict CRT response. Methods: About 49 patients (N = 27 ischemic etiology) received a SPECT RNA scan as well as positron emission tomography (PET) perfusion and viability scans prior to undergoing CRT. A semiautomated algorithm sampled the left ventricle wall to produce 568 TACs from SPECT RNA data. The TACs were then subjected to two different cluster analysis techniques, K-means, and normal average, where several input metrics were also varied to determine the optimal settings for the prediction of CRT outcome. Each TAC was assigned to a cluster group based on the comparison criteria and global and segmental cluster size and scores were used as measures of dyssynchrony and used to predict response to CRT. A repeated random twofold cross-validation technique was used to train and validate the cluster algorithm. Receiver operating characteristic (ROC) analysis was used to calculate the area under the curve (AUC) and compare results to those obtained for SPECT RNA phase analysis and PET scar size analysis methods. Results: Using the normal average cluster analysis approach, the septal wall produced statistically significant results for predicting CRT results in the ischemic population (ROC AUC = 0.73;p < 0.05 vs. equal chance ROC AUC = 0.50) with an optimal operating point of 71% sensitivity and 60% specificity. Cluster

  17. Development and optimization of SPECT gated blood pool cluster analysis for the prediction of CRT outcome

    International Nuclear Information System (INIS)

    Lalonde, Michel; Wassenaar, Richard; Wells, R. Glenn; Birnie, David; Ruddy, Terrence D.

    2014-01-01

    Purpose: Phase analysis of single photon emission computed tomography (SPECT) radionuclide angiography (RNA) has been investigated for its potential to predict the outcome of cardiac resynchronization therapy (CRT). However, phase analysis may be limited in its potential at predicting CRT outcome as valuable information may be lost by assuming that time-activity curves (TAC) follow a simple sinusoidal shape. A new method, cluster analysis, is proposed which directly evaluates the TACs and may lead to a better understanding of dyssynchrony patterns and CRT outcome. Cluster analysis algorithms were developed and optimized to maximize their ability to predict CRT response. Methods: About 49 patients (N = 27 ischemic etiology) received a SPECT RNA scan as well as positron emission tomography (PET) perfusion and viability scans prior to undergoing CRT. A semiautomated algorithm sampled the left ventricle wall to produce 568 TACs from SPECT RNA data. The TACs were then subjected to two different cluster analysis techniques, K-means, and normal average, where several input metrics were also varied to determine the optimal settings for the prediction of CRT outcome. Each TAC was assigned to a cluster group based on the comparison criteria and global and segmental cluster size and scores were used as measures of dyssynchrony and used to predict response to CRT. A repeated random twofold cross-validation technique was used to train and validate the cluster algorithm. Receiver operating characteristic (ROC) analysis was used to calculate the area under the curve (AUC) and compare results to those obtained for SPECT RNA phase analysis and PET scar size analysis methods. Results: Using the normal average cluster analysis approach, the septal wall produced statistically significant results for predicting CRT results in the ischemic population (ROC AUC = 0.73;p < 0.05 vs. equal chance ROC AUC = 0.50) with an optimal operating point of 71% sensitivity and 60% specificity. Cluster

  18. Examination of attenuation correction method for cerebral blood Flow SPECT Using MR imaging

    International Nuclear Information System (INIS)

    Mizuno, Takashi; Takahashi, Masaaki

    2009-01-01

    Authors developed a software for attenuation correction using MR imaging (MRAC) (Toshiba Med. System Engineer.) based on the idea that precision of AC could be improved by the head contour in MRI T2-weighted images (T2WI) obtained before 123 I-iofetamine (IMP) single photon emission computed tomography (SPECT) for cerebral blood flow (CBF) measurement. In the present study, this MRAC was retrospectively evaluated by comparison with the previous standard AC methods derived from transmission CT (TCT) and X-CT which overcoming the problem of sinogram threshold Chang method but still having cost and patient exposure issues. MRAC was essentially performed in the Toshiba GMS5500/PI processor where 3D registration was conducted with images of SPECT and MRI of the same patient. The gamma camera for 123 I-IMP SPECT and 99m TcO 4 - TCT was Toshiba 3-detector GCA9300A equipped with the above processor for MRAC and with low energy high resolution (LEHR) fan beam collimator. Machines for MRI and CT were Siemens-Asahi Meditech. MAGNETOM Symphony 1.5T and SOMATOM plus4, respectively. MRAC was examined in 8 patients with images of T1WI, TCT and SPECT, and in 18 of T2WI, CT and SPECT. Evaluation was made by comparison of attenuation coefficients (μ) by the 4 methods. As a result, the present MRAC was found to be closer to AC by TCT and CT than by the Chang method since MRAC, due to exact imaging of the head contour, was independent on radiation count, and was thought to be useful for improving the precision of CBF SPECT. (K.T.)

  19. Evaluation of {sup 99m}Tc-ECD SPECT for the detection of brain tumor. Comparison with {sup 201}Tl SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Oshima, Motoo; Sasaki, Yasushi; Kikuchi, Yoshirou; Kaminaga, Tatsuro; Furui, Shigeru [Teikyo Univ., Tokyo (Japan). Faculty of Medicine; Konoeda, Kouichi; Karigome, Masato; Yoshida, Katsuhiko

    1997-01-01

    For the evaluation of brain tumor (n=15), we performed both dynamic and static {sup 99m}Tc-ECD (ECD) SPECT studies. {sup 201}Tl SPECT was also used for comparison with the results of ECD SPECT. Dynamic ECD SPECT was obtained following the injection of 600 MBq of ECD. Five min after the injection of ECD, static ECD SPECT was performed. {sup 201}Tl SPECT was obtained 10 min after the injection of 74 MBq. Abnormal uptake was recognized in 7 of 15 tumors with dynamic ECD; 5 of 7 meningiomas, 1 of 1 glioblastoma and 1 of 1 astrocytoma. However, no abnormal uptake was seen in 3 of 3 benign tumors (1 low grade astrocytoma, 1 hemangioma, 1 craniopharyngioma) and in 2 of 2 brain metastases. In contrast abnormal uptake was seen in 11 of 15 tumors with {sup 201}Tl; 7 of 7 meningiomas, 2 of 2 brain metastases, 1 of 1 glioblastoma and 1 of 1 craniopharyngioma. No abnormal uptake was seen in 3 of 3 benign tumors (1 hemangioma and 2 low grade astrocytomas). Equivocal uptake was seen in 1 low grade astrocytoma with dynamic ECD and {sup 201}Tl. The mechanism of the accumulation of dynamic ECD to brain tumor is unclear. However, it may reflect not only blood flow, but also metabolism. (author)

  20. Blood lipid levels and SPECT of myocardium perfusion to type 2 asymptomatic diabetic patients

    International Nuclear Information System (INIS)

    Pena Quian, Yamile; Fernandez-Britto Rodriguez, Jose; Coca Perez, Marco A; Batista Cuellar, Juan F; Rochela Vazquez, Luis Manuel

    2006-01-01

    SPECT, coronary angiography and laboratories test were performed on 31 asymptomatic type 2 diabetes patients, in order to determine the relationship among the lipid levels in blood and the results of the SPECT. Patients were classified in two groups (positive SPECT or negative SPECT). Simple descriptive statistics were calculated for all variables in both groups. Positive SPECT was detected in 35,5% of the patients and negative SPECT in 64,5%.The coronary angiography and SPECT showed good correlation. Low values of HDLc showed significant association with the positive results of the SPECT. The logistical regression showed an increment of the capacity to predict a positive SPECT if the values of HDLc are used. Conclusion: The present investigation demonstrated a significant association among the low levels of HDLc in blood and the positive results of the SPECT. The low values of HDLc could predict the possibility of a positive SPECT in asymptomatic diabetic type 2 patients (au)

  1. Parametric tomography of the cardiac blood pool

    International Nuclear Information System (INIS)

    Meyer, M.; Schwartz, K.D.

    1990-01-01

    In nuclear cardiology image processing is performed usually in 3 of 4 dimensions. ECG-gated SPECT (GSPECT) would make it possible to obtain all 4 dimensions of space and time during one examination, but its duration as well as radiation dose is limited resulting in a low signal-to-noise ratio. Sensitive feature extractions from the amount of data are necessary, e.g. Fourier filtering or extracting isovolumetric intervals. The relatively large amount of calculations and storage requirements often handicaps tomographic ventriculography because a high number of sections have to be processed and the temporal resolution is limited. A new list-mode oriented tomographic algorithm demands less storage and fewer calculations: The Fourier coefficient extraction and the filtered back projection, both of which are linear operations, could be interchanged in the case of thoracic SPECT. The feature extraction algorithm process internal list-mode heart cycles for discrimination of invalid cycles, for end-diastolic and end-systolic synthesis as well as for Fourier analysis of the first harmonic in 10 ms steps. Reconstruction operations are applied also to modified distribution matrices of Fourier coefficients. By only processing 4 spatial matrix sequences (end-diastolic and end-systolic images, amplitude and phase values) parametric tomography becomes practicable and could be also performed by a minicomputer with 64 KByte memory in addition to the possibilities of the planar left ventricular gated imaging. If there are 3 or more processors available a complete feature extraction on-the-fly will be possible. The numerical algorithms were tested with respect to stable reconstructions by phantoms. First results of a patient examination are used to explore effective display techniques, and preliminary modes are demonstrated. It is the purpose of this study to obtain additional information about the gated planar cardiac blood pool imaging in the field of SPECT. (author)

  2. SPECT measurements of cerebral blood volume before and after acetazolamide in occlusive cerebrovascular diseases

    International Nuclear Information System (INIS)

    Inoue, Yusuke; Momose, Toshimitsu; Machida, Kikuo; Honda, Norinari; Nishikawa, Junichi; Sasaki, Yasuhito.

    1994-01-01

    Cerebral blood volume before and after acetazolamide was measured by SPECT to evaluate cerebral vasodilatory capacity in eight patients with cerebrovascular disease and five control subjects. Two SPECT measurements were performed serially, and acetazolamide was administered between them. The ratio of increase in hemispheric blood volume was calculated, and it was compared with the results of cerebral blood flow and cerebral blood volume measurements. A cerebral vasodilatory capacity map, the image after acetazolamide minus the baseline image, was also produced. Acetazolamide increased hemispheric blood volume in all subjects. The ratio of increase was lower in the involved hemispheres of the patients with unilateral carotid disease than in the uninvolved hemispheres of the patients and control subjects. The ratio of concordance with blood flow and blood volume measurements was approximated at 80%. Cerebral vasodilatory capacity mapping revealed three defects compatible with the clinical data. SPECT measurements of cerebral blood volume after acetazolamide can be performed following baseline SPECT with no additional radiotracer, and may be helpful to assess hemodynamic status. (author)

  3. Intrasubject comparison of regional cerebral blood flow between N-isopropyl-p-[123I]iodoamphetamine SPECT and 99mTc-hexamethylpropyleneamine oxime SPECT in patients with ischemic cerebrovascular disease

    International Nuclear Information System (INIS)

    Isaka, Yoshinari; Yoshikawa, Takuya; Ohe, Yohsuke; Nakayama, Hirofumi; Abe, Tohru; Ashida, Keiichi; Imaizumi, Masatoshi; Tanaka, Seiji

    1995-01-01

    Regional cerebral blood flow (CBF) was compared on CBF-SPECT brain images using two perfusion imaging agents, N-isopropyl-p-[ 123 I]iodoamphetamine ( 123 I-IMP) and 99m Tc-hexamethylpropyleneamine oxime ( 99m Tc-HMPAO), in the same patients with ischemic cerebrovascular disease. The subjects were 8 healthy volunteers (group A) and 16 patients with chronic cerebral infarction (group B). SPECT data were normalized to the count density of the tracer in the whole brain, and then converted to the absolute units of CBF by multiplying average 113 Xe-CBF in the whole brain. One-way analysis of variance (ANOVA), grouped by right and left hemispheres in group A and the affected and contralateral hemispheres in group B, was used to assess changes in regional CBF patterns in the two groups. CBF in all regions was significantly reduced on SPECT images, irrespective of the tracers, in group B. F value was higher on IMP images than HMPAO images for the frontal, temporal and occipital cortices, thalamus, and striatum); on the contrary, it was higher on HMPAO images than IMP images for the central lobule, parietal cortex, hippocampus, and centrum semiovale. Two-way ANOVA, grouped by the affected hemisphere in group B, tracer, and affected hemisphere x tracer, indicated that effects of tracer and affected hemisphere x tracer for regional CBF were not significant. For cortical infarction (n=8), regional CBF values in the infarct core were 14.8±4.1 ml/100 g/min on IMP images and 17.6±3.8 ml/100 g/min on HMPAO images; the corresponding figures for the contralateral region were 34.7±8.6 ml/100 g/min and 32.6±8.4 ml/100 g/min. Image contrast was better on IMP images than HMPAO images. In conclusion, an intrasubject comparison in ischemic cerebrovascular disease showed that the detectability of HMPAO CBF-SPECT for CBF abnormalities is roughly equivalent to that of IMP-CBF-SPECT. (N.K.)

  4. End-expiration respiratory gating for a high-resolution stationary cardiac SPECT system

    International Nuclear Information System (INIS)

    Chan, Chung; Sinusas, Albert J; Liu, Chi; Harris, Mark; Le, Max; Biondi, James; Grobshtein, Yariv; Liu, Yi-Hwa

    2014-01-01

    Respiratory and cardiac motions can degrade myocardial perfusion SPECT (MPS) image quality and reduce defect detection and quantitative accuracy. In this study, we developed a dual respiratory and cardiac gating system for a high-resolution fully stationary cardiac SPECT scanner in order to improve the image quality and defect detection. Respiratory motion was monitored using a compressive sensor pillow connected to a dual respiratory–cardiac gating box, which sends cardiac triggers only during end-expiration phases to the single cardiac trigger input on the SPECT scanners. The listmode data were rebinned retrospectively into end-expiration frames for respiratory motion reduction or eight cardiac gates only during end-expiration phases to compensate for both respiratory and cardiac motions. The proposed method was first validated on a motion phantom in the presence and absence of multiple perfusion defects, and then applied on 11 patient studies with and without perfusion defects. In the normal phantom studies, the end-expiration gated SPECT (EXG-SPECT) reduced respiratory motion blur and increased myocardium to blood pool contrast by 51.2% as compared to the ungated images. The proposed method also yielded an average of 11.2% increase in myocardium to defect contrast as compared to the ungated images in the phantom studies with perfusion defects. In the patient studies, EXG-SPECT significantly improved the myocardium to blood pool contrast (p < 0.005) by 24% on average as compared to the ungated images, and led to improved perfusion uniformity across segments on polar maps for normal patients. For a patient with defect, EXG-SPECT improved the defect contrast and definition. The dual respiratory–cardiac gating further reduced the blurring effect, increased the myocardium to blood pool contrast significantly by 36% (p < 0.05) compared to EXG-SPECT, and further improved defect characteristics and visualization of fine structures at the expense of increased

  5. Determination of left ventricular volume using gated blood pool tomography comparison with contrast ventriculography

    International Nuclear Information System (INIS)

    Lu Ping; Mo Lijun; Liu Xiujie

    1992-01-01

    48 patients with cardiac disease were studied with gated blood pool tomography to determine left ventricular volume at end diastole, end-systole and ejection fraction. The volumes were calculated from serial short-axis tomograms by multiplying the number of pixels and the known volume of each pixel. Excellent correlation was found between blood pool tomography and contrast ventriculographic volume. At end-diastole, r = 0.91 (P < 0.01); at end-systole, r = 0.95 (P < 0.01); for left ventricular ejection fraction, r 0.90 (P < 0.01). The results suggest that gated blood pool tomography is a promising noninvasive and direct method for measuring left ventricular volume

  6. Blood pool SPECT for visualization of portosystemic collaterals in portal hypertension

    International Nuclear Information System (INIS)

    Kroiss, A.; Auinger, C.

    1990-01-01

    In 46 patients, 26 male and 20 female, age from 32 to 71 years (mean 47,4 ± 11 years) a bloodpool-scintigraphy (BSP) with SPECT (single photon emission computed tomography) was performed. The in-vivo labelling of the erythrocytes with pyrophosphate and Tc99m was performed in the usual way. The SPECT investigations were performed with a digital Anger-Camera (Elscint; Apex 401). In 14 patients without collaterals BPS was performed to compare the method with patients with liver diseases and collaterals. 29 patients with liver cirrhosis and portal hypertension were investigated with the BSP and additionaly a scintisplenoportography (SSP) was performed. In patients with only cephalad collaterals all the results were concordant. In just 1 patient with cephalad and caudad collaterals we found a discordant result. In 8 patients we performed BSP, SSP and a katheterangiography (KA). Taking the KA as the 'golden standard' we found a concordant result with the 3 methods in all patients with cephalad collaterals. In patients with cephalad and caudad collaterals we once found a discordant result with the SSP and twice with the BSP. In 2 patients the patency of surgical shunts were proved. 2 patients after sclerosis of the oesophageal varices have been proved by BPS and SSP and both patients showed good therapeutical results. (Authors)

  7. Subcortical aphasia and cerebral blood flow using SPECT

    International Nuclear Information System (INIS)

    Celsis, P.; Puel, M.; Demonet, J.P.; Bonafe, A.; Cardebat, D.; Viallard, G.; Pujol, T.; Marc-Vergnes, J.P.; Rascol, A.

    1985-01-01

    Possible cerebral blood flow (CBF) alteration in subcortical aphasia was investigated by single-photon emission tomography (SPECT). The results confirm the capsulo-striatal lesions and also point to the high rate of ipsilateral thalamic and cortical dysfunction. (author). 8 refs.; 1 fig.; 1 tab

  8. Regional cerebral blood flow in SPECT pattern in Parkinson's disease

    International Nuclear Information System (INIS)

    Lenart-Jankowska, D.; Junik, R.; Sowinski, J.; Gembicki, M.; Wender, M.

    1997-01-01

    The purpose of our work was to compare the regional cerebral blood flow (rCBF) in SPECT examination in Parkinson's disease with (17 cases) and without (7 cases) dementia and in various clinical stages of the disease. The patients underwent SPECT examination 5-40 min after intravenous application of HMPAO (Ceretec, Amersham) with 740 Mbq (20 mCi) pertechnate 99m Tc. SPECT was performed with a Siemens Diacam single-head rotating gamma camera coupled to a high resolution collimator and Icon computer system provided by the manufacturer. The results were defined in relative values of ROI in relation to cerebellum. Patients with Parkinson's disease showed hypoperfusion in cerebral lobes and in deep cerebral structures including the basal ganglia. Regional perfusion deficit in SPECT was seen with and without associated dementia and already in early stage of the disease. Parkinson's disease is provoked by the lesions of dopaminergic neurons of the central nervous system leading to domination of extrapyramidal symptoms. There are many indications that also the neurotransmitters associated with cognitive functions as acetylcholine demonstrate some abnormalities. However, only in some cases of Parkinson's disease dementia is the dominating symptom. Our results of regional cerebral blood flow testify that in Parkinson's disease the dysfunction of the central nervous system is more diffuse than has previously been suggested. (author)

  9. The problem in 180 deg data sampling and radioactivity decay correction in gated cardiac blood pool scanning using SPECT

    International Nuclear Information System (INIS)

    Ohtake, Tohru; Watanabe, Toshiaki; Nishikawa, Junichi

    1986-01-01

    In cardiac blood pool scanning using SPECT, half 180 deg data collection (HD) vs. full 360 deg data collection (FD) and Tc-99m decay are problems in quantifying the ejection count (EC) (end-diastolic count - end-systolic count) of both ventricles and the ratio of the ejection count of the right and left ventricles (RVEC/LVEC). We studied the change produced by altering the starting position of data sampling in HD scans. In our results of phantom and 4 clinical cases, when the cardiac axis deviation was not large and there was not remarkable cardiac enlargement, the change in LVEC, RVEC and RVEC/LVEC was small (1 - 4 %) within 12 degree change of the starting position, and the difference between the results of HD scan with a good starting position (the average of LV peak and RV peak) and FD scan was not large (less than 7 %). Because of this, we think HD scan can be used in those cases. But when the cardiac axis deviation was large or there was remarkable cardiac enlargement, the change of LVEC, RVEC and RVEC/LVEC was large (more than 10 %) even within 12 degree change of the starting position. So we think FD scan would be better in those cases. In our results of 6 patients, the half-life of Tc-99m labeled albumin in blood varied from 2 to 4 hr (3.03 ± 0.59 hr, mean ± s.d.). Using a program for radioactivity (RA) decay correction, we studied the change in LVEC, RVEC and LVEC/RVEC in 11 cases. When RA decay correction was performed using a halflife of 3.0 hr, LVEC increased 7.5 %, RVEC increased 8.7 % and RVEC/LVEC increased 0.9 % on the average in HD scans of 8 cases (LPO to RAO, 32 views, 60 beat/1 view). We think RA decay correction would not be needed in quantifying RVEC/LVEC in most cases because the change of RVEC/LVEC was very small. (author)

  10. Quantitation of cerebral blood volume by 99mTc-DTPA-HSA SPECT

    International Nuclear Information System (INIS)

    Inoue, Yusuke; Machida, Kikuo; Momose, Toshimitsu

    1992-01-01

    The characteristics of technetium-99m diethylenetriaminepentaacetic acid human serum albumin ( 99m Tc-DTPA-HSA) as an agent for quantitation of cerebral blood volume (CBV) were examined. The radioactivity after decay correction as a percentage of the activity at 10 minutes was 84.3±1.3% at 120 minutes after the injection of 99m Tc-DTPA-HSA. Radioactivity was found exclusively in plasma, with little in blood cells. The blood retention of 99m Tc-DTPA-HSA is sufficient, and its use in the quantitation of CBV omits the need for centrifugation of the blood sample. CBV quantified using the tracer and a SPECT system with a single-head rotating gamma camera was 4.09±0.60 ml/100g brain, similar to values reported previously. Two serial SPECT scans provided similar images, and the CBV values determined by the two scans were closely correlated (p 99m Tc-DTPA-HSA has useful properties for quantitative CBV measurement and that quantitation of CBV by 99m Tc-DTPA-HSA SPECT is feasible using a system with a single-head rotating gamma camera. (author)

  11. Role of Tc-99m labeled RBC SPECT in haemangioma of the liver

    International Nuclear Information System (INIS)

    Saddadi, Fariba; Kamali, Hosein; Faghihi, Amir Hosein; Shokouhizadeh, Reza

    2004-01-01

    Full text: Haemangioma of the liver must be included in the differential diagnosis of all focal hepatic lesions. Nuclear medicine imaging techniques continue to play a unique role in the evaluation of hepatic masses. Role of planar scintigraphy in the diagnosis of hepatic haemangioma is already established although it has limitations, which can be significantly improved by means of SPECT studies. A prospective study was carried out to evaluate Tc-99m red blood cell SPECT imaging in liver haemangioma and compare it with CT findings. Radionuclide liver scan, both planar and SPECT was done in 10 patients who had 16 liver masses diagnosed as haemangiomas on their CT. The acquisition protocol was an immediate perfusion phase study in an anterior view followed by SPECT of the liver at 2 hours. A perfusion/blood-pool mismatch is the hallmark finding for hepatic haemangioma. The smallest haemangioma detected with isotope scan was of 1.55 cm size. Planar scintigraphy showed a sensitivity of 82% versus 94.2% for SPECT. It was mostly due to missing of lesions less than 2 cm in size on planar scans. For cavernous haemangioma (n=4) the specificity and positive predictive value was 100%. We believe that hepatic scintigraphy still continues to play an important role in the diagnosis of hepatic masses especially for liver haemangioma where Tc-99m labeled red blood cell scanning has considerably high specificity. However, planar imaging has poor sensitivity especially for the identification of smaller lesions. Hepatic scintigraphy is non-invasive, easy to perform and inexpensive. In our opinion, when a suspicion of hepatic haemangioma is raised on CT or other imaging modalities, it needs to be confirmed by radionuclide blood-pool study. (author)

  12. Study of regional cerebral blood flow SPECT imaging for sudden sensorineural deafness

    International Nuclear Information System (INIS)

    Xie Changhui; Kui Xixiao; Xiong Qibin; Wen Hui; Xie Jiabiao

    1998-01-01

    Purpose: To study the clinical value of regional cerebral blood flow (rCBF) SPECT imaging for sudden sensorineural deafness (SSD). Methods: 10 normal persons, 19 conductive deafness and 31 SSD patients were examined by rCBF SPECT imaging, and compared with X CT at the same time. All SSD patients were followed up for 6∼12 months with repeated rCBF SPECT imaging. Results: 1) The radioactivity of diseased and normal horizontal temporal gyrus ratio (T/NT) in SSD patients was the lowest among three groups (P < 0.01). 2) The sensitivity (80.6%) and accurate rate (88.3%) of rCBF SPECT imaging in SSD patients were much higher than those of CT (3.2% and 50%, P < 0.01). 3) There was a significant correlation between degree of deafness and T/NT in SSD patients. 4) Good prognosis of SSD patients with normal rCBF SPECT was found. 5) The rCBF SPECT had close concordance between rCBF SPECT imaging and clinical prognosis (84.6%). Conclusions: rCBF SPECT imaging was superior to X CT in diagnosis of SSD and played an important clinical role

  13. 99mTc-HMPAO SPECT thalamic blood flow study in migraine

    International Nuclear Information System (INIS)

    Zhang Zhijian; Steiner, T.J.

    1995-01-01

    The changes of blood flow in the thalamic of migraineurs by 99m Tc-HMPAO SPECT imaging are investigated. 60 cases with migraine were performed by Novo 810 high-resolution SPECT 30 minutes after injection of 99m Tc-HMPAO. The quantitative analysis of SPECT data was based on the irregular ROI% uptake normalized to total slice method. There were significantly increased mean % uptake values in migraine with aura (259.1 +-17.1), and more significantly in those who experienced hemisensory symptoms and hemiparesis during aura (263.8 +- 17.2), compared to that of migraine without aura (249.1 +- 14.9), but there were not statistically significant difference between migraine with only visual disturbance during aura (255.1 +- 16.4) and without aura. The possible explanations for the increased mean % uptake values in migraineurs who experienced hemisensory symptoms and hemiparesis during aura are: (1) the reactive postischemic hyperemia. (2) excepting thalamus, the regional blood flow was decreased. (3) the secondary phenomenon to the various neurogenic and chemical stimuli

  14. In vivo quantification of {sup 177}Lu with planar whole-body and SPECT/CT gamma camera imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, Dale L. [Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, NSW 2065 (Australia); Faculty of Health Sciences, University of Sydney, Cumberland, NSW (Australia); Sydney Medical School, University of Sydney, Camperdown, NSW (Australia); NETwork, Sydney Vital, St Leonards, Sydney, NSW (Australia); Hennessy, Thomas M.; Willowson, Kathy P.; Henry, E. Courtney [Institute of Medical Physics, University of Sydney, Camperdown, NSW (Australia); Chan, David L.H. [Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, NSW 2065 (Australia); NETwork, Sydney Vital, St Leonards, Sydney, NSW (Australia); Aslani, Alireza [Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, NSW 2065 (Australia); Roach, Paul J. [Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, NSW 2065 (Australia); Sydney Medical School, University of Sydney, Camperdown, NSW (Australia)

    2015-09-17

    Advances in gamma camera technology and the emergence of a number of new theranostic radiopharmaceutical pairings have re-awakened interest in in vivo quantification with single-photon-emitting radionuclides. We have implemented and validated methodology to provide quantitative imaging of {sup 177}Lu for 2D whole-body planar studies and for 3D tomographic imaging with single-photon emission computed tomography (SPECT)/CT. Whole-body planar scans were performed on subjects to whom a known amount of [{sup 177}Lu]-DOTA-octreotate had been administered for therapy. The total radioactivity estimated from the images was compared with the known amount of the radionuclide therapy administered. In separate studies, venous blood samples were withdrawn from subjects after administration of [{sup 177}Lu]-DOTA-octreotate while a SPECT acquisition was in progress and the concentration of the radionuclide in the venous blood sample compared with that estimated from large blood pool structures in the SPECT reconstruction. The total radioactivity contained within an internal SPECT calibration standard was also assessed. In the whole-body planar scans (n = 28), the estimated total body radioactivity was accurate to within +4.6 ± 5.9 % (range −17.1 to +11.2 %) of the correct value. In the SPECT reconstructions (n = 12), the radioactivity concentration in the cardiac blood pool was accurate to within −4.0 ± 7.8 % (range −16.1 to +7.5 %) of the true value and the internal standard measurements (n = 89) were within 2.0 ± 8.5 % (range −16.3 to +24.2 %) of the known amount of radioactivity contained. In our hands, state-of-the-art hybrid SPECT/CT gamma cameras were able to provide accurate estimates of in vivo radioactivity to better than, on average, ±10 % for use in biodistribution and radionuclide dosimetry calculations.

  15. Clinical comparison of cardiac blood pool visualization with technetium-99m red blood cells labeled in vivo and with technetium-99m human serum albumin

    International Nuclear Information System (INIS)

    Thrall, J.H.; Freitas, J.E.; Swanson, D.; Rogers, W.L.; Clare, J.M.; Brown, M.L.; Pitt, B.

    1978-01-01

    Technetium-99m red blood cells (Tc-RBC) labeled by an in vivo technique were compared with two preparations of Tc-99m human serum albumin (HSA) for cardiac blood-pool imaging. Relative distribution of the tracers was analyzed on end-diastolic frames of gated blood-pool studies and on whole-body (head to mid-thigh) anterior pinhole images. The Tc-RBC demonstrated greater relative percentage localization in the cardiac blood pool, higher target-to-background ratios in the left ventricle, and less liver concentration. For cardiac blood-pool imaging, Tc-RBC labeled by the in vivo approach appears to be superior to the two Tc-HSA preparations studied

  16. Comparison of SPECT and whole-body planar imaging in radioimmunoscintigraphy with Tc-labeled antibodies

    International Nuclear Information System (INIS)

    Lacic, K.; Bokulic, T.; Lukac, J.; Dakovic, N.; Kusic, Z.

    1994-01-01

    The authors of some recent clinical studies suggested 20-24 hours SPECT imaging as a mandatory procedure in radioimmunoscintigraphy with Tc-labeled antibodies. The aim of our study was to compare whole-body (WB) planar imaging versus SPECT as well as 4-6 hours SPECT to 20-24 hours one. For this purpose we analyzed 33 lesions in 12 postsurgical patients with colorectal carcinoma. Each patient received intravenously 0.5-1.0 mg anti-CEA BW 431/26 murine monoclonal IgG-antibodies labeled with Tc-99m (814-1110 MBq). WB and SPECT imaging were performed at 4-6 and 20-24 hours post infusion. 20-24 hours WB scan imaged more 'hot' and less 'cold' lesions than 4-6 hours one. SPECT scan showed significantly more lesions than WB scan. 20-24 hours SPECT scan detected more 'hot' lesions than 4-6 hours SPECT. At the same time the number of 'cold' lesions decreased in 20-24 hours SPECT in comparison to 4-6 hours one. As a conclusion we can say that our results suggest a superiority of SPECT imaging in comparison to WB scan. Except that, in our opinion performing of a 20-24 hours SPECT scan in radioimmunoscintigraphy with Tc-labeled antibodies should be mandatory. (author)

  17. Comparison of SPECT and whole-body planar imaging in radioimmunoscintigraphy with Tc-labeled antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Lacic, K; Bokulic, T; Lukac, J; Dakovic, N; Kusic, Z [Clinical Hospital Sestre Milosrdnice, Zagreb (Croatia). Dept. of Oncology and Nuclear Medicine

    1994-10-01

    The authors of some recent clinical studies suggested 20-24 hours SPECT imaging as a mandatory procedure in radioimmunoscintigraphy with Tc-labeled antibodies. The aim of our study was to compare whole-body (WB) planar imaging versus SPECT as well as 4-6 hours SPECT to 20-24 hours one. For this purpose we analyzed 33 lesions in 12 postsurgical patients with colorectal carcinoma. Each patient received intravenously 0.5-1.0 mg anti-CEA BW 431/26 murine monoclonal IgG-antibodies labeled with Tc-99m (814-1110 MBq). WB and SPECT imaging were performed at 4-6 and 20-24 hours post infusion. 20-24 hours WB scan imaged more `hot` and less `cold` lesions than 4-6 hours one. SPECT scan showed significantly more lesions than WB scan. 20-24 hours SPECT scan detected more `hot` lesions than 4-6 hours SPECT. At the same time the number of `cold` lesions decreased in 20-24 hours SPECT in comparison to 4-6 hours one. As a conclusion we can say that our results suggest a superiority of SPECT imaging in comparison to WB scan. Except that, in our opinion performing of a 20-24 hours SPECT scan in radioimmunoscintigraphy with Tc-labeled antibodies should be mandatory. (author).

  18. Clinical usefullness of ECG-triggered single photon emission comuter tomography of blood-pool

    International Nuclear Information System (INIS)

    Eilles, Chr.; Boerner, W.; Strauss, P.; Gerhards, W.; Reiners, Ch.

    1982-01-01

    ECT allows direct measurement of the volume of an organ and imaging without disturbing background-superposition. This makes ECT to an useful instrument for ECG-gated blood-pool imaging. Acquisition is made after the injection of 25 mCi Tc-99m HSA with a rotating Anger-Camera-System. ECG-gated imaging is done for each projection; herewith 50-70 cycles per projection are added according to the phase of the heart-cycle. Transversal-Sections of the heart are reconstructed with filtered-back-projection. For each slice a representative cycle, consisting of 10-16 frames, is computed. As shown by our group before a good quality of the reconstructed images can be obtained. Comparison is made with the results of the ECG-gated blood-pool-ECT, the results of the conventional blood-pool-studies and with the results of Laevo-Cardiography. (Author)

  19. Decreased cerebral blood flow and prognosis of Alzheimer's disease. A multicenter HMPAO-SPECT study

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Hashikawa, Kazuo; Fukuyama, Hidenao

    2007-01-01

    The purpose of this study was to determine the usefulness of brain perfusion single photon emission computed tomography (SPECT) for evaluating the severity and progression of Alzheimer's disease (AD). Eighty-four AD patients were included. At entry, 99m Tc-HMPAO-SPECT, the Mini Mental State Examination (MMSE), Mental Function Impairment Scale (MENFIS), and the Raven Colored Progression Matrix (RCPM) were performed for all 84 patients. During the follow-up periods, two individual MMSE evaluations in 34 patients, two MENFIS evaluations in 30 patients, and two RCPM evaluations in 20 patients were performed. Based on the regions of decreased cerebral blood flow demonstrated on three-dimensional stereotactic surface projection (3D-SSP) images of SPECT, the cases were classified as type A (no decrease), type B (decreased blood flow in the parietal or temporal lobe), type C (decreased blood flow in the frontal lobe and parietal or temporal lobe), type Pc (decreased blood flow in posterior cingulate gyrus only), and ''other types''. The types of decreased blood flow, scores on neuropsychological evaluations, and symptom progression were analyzed. The MENFIS, MMSE, and RCPM scores were poorest in type C patients at entry. The degree of decrease of these scores during the follow-up periods was also greatest in type C. The greatest difference between patients with and without rapid progression in SPECT data of the mild AD patients (MMSE score≥24) was in the frontal lobe. Decreased blood flow in the frontal lobe of AD patients is correlated not only with reduced cognitive function at the time of the evaluation but with rapid progression in the subsequent clinical course. (author)

  20. Cortical region of interest definition on SPECT brain images using X-ray CT registration

    Energy Technology Data Exchange (ETDEWEB)

    Tzourio, N.; Sutton, D. (Commissariat a l' Energie Atomique, Orsay (France). Service Hospitalier Frederic Joliot); Joliot, M. (Commissariat a l' Energie Atomique, Orsay (France). Service Hospitalier Frederic Joliot INSERM, Orsay (France)); Mazoyer, B.M. (Commissariat a l' Energie Atomique, Orsay (France). Service Hospitalier Frederic Joliot Antenne d' Information Medicale, C.H.U. Bichat, Paris (France)); Charlot, V. (Hopital Louis Mourier, Colombes (France). Service de Psychiatrie); Salamon, G. (CHU La Timone, Marseille (France). Service de Neuroradiologie)

    1992-11-01

    We present a method for brain single photon emission computed tomography (SPECT) analysis based on individual registration of anatomical (CT) and functional ([sup 133]Xe regional cerebral blood flow) images and on the definition of three-dimensional functional regions of interest. Registration of CT and SPECT is performed through adjustment of CT-defined cortex limits to the SPECT image. Regions are defined by sectioning a cortical ribbon on the CT images, copied over the SPECT images and pooled through slices to give 3D cortical regions of interest. The proposed method shows good intra- and interobserver reproducibility (regional intraclass correlation coefficient [approx equal]0.98), and good accuracy in terms of repositioning ([approx equal]3.5 mm) as compared to the SPECT image resolution (14 mm). The method should be particularly useful for analysing SPECT studies when variations in brain anatomy (normal or abnormal) must be accounted for. (orig.).

  1. Single-Photon Emission Computed Tomography (SPECT) in childhood epilepsy

    International Nuclear Information System (INIS)

    Gulati, Sheffali; Kalra, Veena; Bal, C.S.

    2000-01-01

    The success of epilepsy surgery is determined strongly by the precise location of the epileptogenic focus. The information from clinical electrophysiological data needs to be strengthened by functional neuroimaging techniques. Single photon emission computed tomography (SPECT) available locally has proved useful as a localising investigation. It evaluates the regional cerebral blood flow and the comparison between ictal and interictal blood flow on SPECT has proved to be a sensitive nuclear marker for the site of seizure onset. Many studies justify the utility of SPECT in localising lesions to possess greater precision than interictal scalp EEG or anatomic neuroimaging. SPECT is of definitive value in temporal lobe epilepsy. Its role in extratemporal lobe epilepsy is less clearly defined. It is useful in various other generalized and partial seizure disorders including epileptic syndromes and helps in differentiating pseudoseizures from true seizures. The need for newer radiopharmaceutical agents with specific neurochemical properties and longer shelf life are under investigation. Subtraction ictal SPECT co-registered to MRI is a promising new modality. (author)

  2. Cerebral blood flow SPECT scanning in cortico-basal degeneration

    International Nuclear Information System (INIS)

    Slawek, J.; Walczak, A.; Krupa-Olchawa, J.; Lass, P.; Dubaniewicz, M.

    1999-01-01

    Idiopathic Parkinson's disease accounts for ca. 75% of all cases of Parkinsonism. Corticobasal degeneration is a relatively rare example of the so-called ''Parkinson-plus'' syndrome. The authors present the case of a 56-year-old woman with rigidity and atypical tremor of upper extremity followed by gait apraxia, dysarthria, bilateral pyramidal signs and myoclonus. There was no improvement after treatment with L-dopa. The disease has progressed, but the patient is still alive. On the basis of clinical data a diagnosis of corticobasal degeneration has been established. Cerebral blood flow SPECT scanning revealed diffuse hypoperfusion of left frontal lobe, antero-inferior part of the left temporal lobe and left basal ganglia. The case illustrates the usefulness of brain SPECT in atypical forma of Parkinson's disease. (author)

  3. Use of blood-pool imaging in evaluation of diffuse activity patterns in technetium-99m pyrophosphate myocardial scintigraphy.

    Science.gov (United States)

    Cowley, M J; Mantle, J A; Rogers, W J; Russell, R O; Rackley, C E; Logic, J R

    1979-06-01

    It has been suggested that diffuse Tc-99m pyrophosphate precordial activity may be due to persistent blood-pool activity in routine delayed views during myocardial imaging. To answer this question, we reviewed myocardial scintigrams recorded 60--90 min following the injection of 12--15 mCi of Tc-99m pyrophosphate for the presence of diffuse precordial activity, and compared these with early images of the blood pool in 265 patients. Diffuse activity in the delayed images was identified in 48 patients: in 20 with acute myocardial infarction and in 28 with no evidence of it. Comparison of these routine delayed images with early views of the blood pool revealed two types of patterns. In patients with acute infarction, 95% had delayed images that were distinguishable from blood pool either because the activity was smaller than the early blood pool, or by the presence of localized activity superimposed on diffuse activity identical to blood pool. In those without infarction, 93% had activity distribution in routine delayed views matching that in the early blood-pool images. The usefulness of the diffuse TcPPi precordial activity in myocardial infarction is improved when early blood-pool imaging is used to exclude persistence of blood-pool activity as its cause. Moreover, it does not require additional amounts of radioactivity nor complex computer processing, a feature that may be of value in the community hospital using the technique to "rule out" infarction 24--72 hr after onset of suggestive symptoms.

  4. Storage characteristics of multiple-donor pooled red blood cells compared to single-donor red blood cell units.

    Science.gov (United States)

    Mathur, Aabhas; Chowdhury, Raquibul; Hillyer, Christopher D; Mitchell, W Beau; Shaz, Beth H

    2016-12-01

    Each unit of blood donated is processed and stored individually resulting in variability in the amount of red blood cells (RBCs) collected, RBC properties, and the 24-hour posttransfusion RBC survivability. As a result, each unit differs in its ability to deliver oxygen and potentially its effects on the recipient. The goal of this study was to investigate the storage of pooled RBCs from multiple donors in comparison to control standard RBC units. Two units of irradiated, leukoreduced RBCs of same ABO, D, E, C, and K antigen phenotype were collected from each of five donors using apheresis. One unit from each donor was pooled in a 2-L bag and remaining units were used as controls. After being pooled, RBCs were separated in five bags and stored at 4°C along with the controls. Quality indexes were measured on Days 2, 14, and 28 for all the units. Adenosine triphosphate assays for both pooled and controls showed a slight decrease from Day 2 to Day 28 (pooled/control from 5.22/5.24 to 4.35/4.33 µmol/g hemoglobin [Hb]). 2,3-Diphosphoglycerate was successfully rejuvenated for all RBC units on Day 28 (pooled 11.46 µmol/g Hb; control 11.86 µmol/g Hb). The results showed a nonsignificant difference between pooled and control units, with a general trend of lower standard deviation for pooled units when compared to controls. Pooled units have reduced unit-to-unit variability. Future exploration of their immunogenicity is required before using pooled units for transfusion. © 2016 AABB.

  5. The need of appropriate brain SPECT templates for SPM comparisons

    International Nuclear Information System (INIS)

    Morbelli, S.; Altrinetti, V.; Piccardo, A.; Rodriguez, G.; Brugnolo, A.; Nobili, F.; Mignone, A.; Pupi, A.; Koulibaly, P.M.

    2008-01-01

    Statistical parametric mapping (SPM) is used worldwide to compare brain perfusion single photon emission computed tomography (SPECT) data. The default template within the SPM package used for SPECT image normalization includes images of a group of healthy subjects studied with 99m TcHMPAO. Since [ 99m Tc] HMPAO and [ 99m Tc] ECD have shown to distribute differently in SPECT studies, we formulated the hypothesis that comparing set of [ 99m Tc]ECD data normalized by means of a [ 99m Tc]HMPAO template may lead to incorrect results. A customized [ 99m Tc]ECD template was built with SPECT and magnetic resonance imaging (MRI) images of 22 neurologically healthy women. Then, two sets of subjects, i.e. a group of patients with very early Alzheimer's disease (eAD) and a matched control group, studied by means of [ 99m Tc]ECD SPECT, were chosen for comparisons. The same statistical approach (t-test between eAD patients and controls and correlation analysis between brain SPECT and a cognitive score) was applied twice, i.e. after normalization with either the default [ 99m Tc]HMPAO template or the customized [ 99m Tc]ECD template. In the comparison between eAD and controls, a cluster of difference in the posterior-cingulate gyrus of both hemispheres was only highlighted when using the customized [ 99m Tc]ECD template, but was missed when using the default [ 99m Tc]HMPAO template. In the correlation between brain perfusion and a cognitive score, the significant cluster was more significant and far more extended, also including the right superior temporal gyrus, using the customized [ 99m Tc]ECD template than using the default [ 99m Tc]HMPAO template. These data suggest the need of customized, radiopharmaceutical-matched SPECT templates to be used within the SPM package. The present customized [ 99m Tc]ECD template is now freely available on the web. (authors)

  6. Use of blood-pool imaging in evaluation of diffuse activity patterns in technetium-99m pyrophosphate myocardial scintigraphy

    International Nuclear Information System (INIS)

    Cowley, M.J.; Mantle, J.A.; Rogers, W.J.; Russell, R.O. Jr.; Rackley, C.E.; Logic, J.R.

    1979-01-01

    It has been suggested that diffuse 99m Tc pyrophosphate precordial activity may be due to persistent blood-pool activity in routine delayed views during myocardial imaging. To answer this question, we reviewed myocardial scintigrams recorded 60 to 90 min following the injection of 12 to 15 mCi of 99m Tc pyrophosphate for the presence of diffuse precordial activity, and compared these with early images of the blood pool in 265 patients. Diffuse activity in the delayed images was identified in 48 patients: in 20 with acute myocardial infarction and in 28 with no evidence of it. Comparison of these routine delayed images with early views of the blood pool revealed two types of patterns. In patients with acute infarction, 95% had delayed images that were distinguishable from blood pool either because the activity was smaller than the early blood pool, or by the presence of localized activity superimposed on diffuse activity identical to blood pool. In those without infarction, 93% had activity distribution in routine delayed views matching that in the early blood-pool images. The usefulness of the diffuse TcPPi precordial activity in myocardial infarction is improved when early blood-pool imaging is used to exclude persistence of blood-pool activity as its cause. Moreover, it does not require additional amounts of radioactivity nor complex computer processing, a feature that may be of value in the community hospital using the technique to rule out infarction 24 to 72 hr after onset of suggestive symptoms

  7. A comparison among 123I-IMP SPECT, EEG and MRI in patients with temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Tatsu, Yoshimitsu; Nishigaki, Hiroshi; Adachi, Itaru

    1994-01-01

    N-isopropyl-p-[ 123 I]iodoamphetamine ( 123 I-IMP) single photon emission computed tomography (SPECT), electroencephalography (EEG), and magnetic resonance imaging (MRI) were performed in 19 patients with temporal lobe epilepsy during interictal stage. MRI demonstrated abnormal signal in mesial temporal lobe (hippocampus) in 10 of 19 patients and 123 I-IMP SPECT showed a hypoperfusion area in 15 of 19 patients. When compared with EEG and MRI data, disagreement of the affected area was observed in 3 cases. In comparison of EEG and 123 I-IMP SPECT data, disagreement of the affected area was observed in 6 cases. Although there was no disagreement in comparison of MRI and 123 I-IMP SPECT. We made a reprojection data parallel to the hippocampus in 123 I-IMP SPECT. These data demonstrated obviously a hypoperfusion area around the hippocampus. In cases within one month from seizure attack, wide hypoperfusion area was showed on 123 I-IMP SPECT in comparison of abnormal signal area on MRI. It could be considered that a reprojection data parallel to the hippocampus was useful to know extent of hypoperfusion area in temporal lobe epilepsy. (author)

  8. Comparison of 18F-FDG PET and 201 thallium chloride SPECT in the evaluation of cerebral glioma prior to surgery

    International Nuclear Information System (INIS)

    Poon, A.M.T.; Cher, L.; Berlangieri, S.U.; Fabinyi, G.; Tochon-Danguy, H.; Chan, J.G.; Scott, A.M.

    2000-01-01

    Full text: The purpose of the study was to compare the accuracy of 18 F-FDG PET and 201 Tl SPECT in detecting and grading primary cerebral glioma through comparison to surgical pathology. A total of 33 patients with primary cerebral glioma had 35 18 F-FDG PET/ 201 Tl SPECT scans prior to surgery. Pre-operative 18 F -FDG PET and 201 Tl SPECT studies were reviewed and compared with histologic tumour grade. Radiological comparisons were also performed when pre-operative studies were available. 17/18 patients with glioblastoma multiforme demonstrated hypermetabolic lesions on 18 F-FDG PET scan and increased thallium uptake on SPECT scan. Increased 18 F -FDG and thallium uptake were also demonstrated in patients with anaplastic astrocytoma, gemistocytic astrocytoma, and one biopsy which was difficult to grade because of small biopsy sample and co-existing radiation necrosis. In general, low grade gliomas had reduced 18 F -FDG uptake and normal thallium uptake (6/7, where two patients had tumour with hypermetabolic and hypometabolic regions). MRI correctly identified 4/7 patients with low to intermediate grade glioma. Pilocytic astrocytoma, protoplastic astrocytoma and oligoastrocytoma all demonstrated hypometabolic PET activity and normal thallium uptake. In conclusion, 18 F-FDG PET and 201 Tl SPECT are very sensitive in pre-operative prediction of high grade glioma. In low grade tumour, 201 Tl SPECT appeared to be less useful in the absence of breakdown of the blood brain barrier. MR imaging accurately identified the presence of tumour but was less accurate in determining the grade of tumour. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  9. MRT of experimental liver abscesses - comparison of a new blood pool contrast agent with gadolinium-DTPA

    International Nuclear Information System (INIS)

    Dick, A.; Adam, G.; Spuentrup, E.; Prescher, A.; Muehler, A.; Guenther, R.W.

    1996-01-01

    Purpose: In an experimental pyogenic liver abscess model, the signal intensities were compared intraindividually and interindividually after the application of a new blood pool contrast agent, 24-gadolinium-DTPA (diethylenetriamine-pentaacetic acid) cascade polymer, and after the application of gadopentetate dimeglumine. Methods: In 20 rabbits with experimentally induced liver abscesses, the relative signal intensities of the liver, abscess centre, abscess wall and portal vein were assessed before and between 30 seconds and 60 minutes after injection of a 25 μmol/kg dose of gadolinium polymer and of 100 μmol/kg of gadolinium-DTPA, respectively. Measurements were performed at 1.5 Tesla, using a head coil and a Flash-2-D sequence. Results: The interindividual comparison (unpaired T-test, p [de

  10. Phase analysis in gated blood pool tomography

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Bunko, Hisashi; Tada, Akira; Taki, Junichi; Nanbu, Ichiro

    1984-01-01

    Phase analysis of gated blood pool study has been applied to detect the site of accessory conduction pathway (ACP) in the Wolff-Parkinson-White (WPW) syndrome; however, there was a limitation to detect the precise location of ACP by phase analysis alone. In this study, we applied phase analysis to gated blood pool tomography using seven pin hole tomography (7PT) and gated emission computed tomography (GECT) in 21 patients with WPW syndrome and 3 normal subjects. In 17 patients, the sites of ACPs were confirmed by epicardial mapping and the result of the surgical division of ACP. In 7PT, the site of ACP grossly agreed to the abnormal initial phase in phase image in 5 out of 6 patients with left cardiac type. In GECT, phase images were generated in short axial, vertical and horizontal long axial sections. In 8 out of 9 patients, the site of ACP was correctly identified by phase images, and in a patient who had two ACPs, initial phase corresponded to one of the two locations. Phase analysis of gated blood pool tomography has advantages for avoiding overlap of blood pools and for estimating three-dimensional propagation of the contraction, and can be a good adjunctive method in patients with WPW syndrome. (author)

  11. Increased cerebral blood flow in MELAS shown by Tc-99m HMPAO brain SPECT

    International Nuclear Information System (INIS)

    Peng, N.J.; Tsay, D.G.; Liu, R.S.; Li, J.Y.; Kong, K.W.; Kwok, C.G.; Strauss, H.W.

    2000-01-01

    We report cerebral SPECT studies on two siblings with the syndrome of mitochondrial myopathy, encephalopathy, lactic acidosis and stroke-like episodes (MELAS). Tc-99m HMPAO brain SPECT was performed 8, 19 and 30 days after a stroke-like episode in one case and 10 days after a stroke-like episode, 6 h after a partial seizure and as a follow-up study in the other. Increased blood flow was seen in both these patients with stroke-like episodes due to MELAS. The cause of the increased blood flow is uncertain, but it may be related to the decreased pH created by local increase in lactic acid. (orig.)

  12. SPECT myocardial blood flow quantitation toward clinical use: a comparative study with {sup 13}N-Ammonia PET myocardial blood flow quantitation

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Bailing [University of Missouri-Columbia, Nuclear Science and Engineering Institute, Columbia, Missouri (United States); Hu, Lien-Hsin; Yang, Bang-Hung; Ting, Chien-Hsin; Huang, Wen-Sheng [Taipei Veterans General Hospital, Department of Nuclear Medicine, Taipei (China); Chen, Lung-Ching [Shin Kong Wu-Ho Su Memorial Hospital, Division of Cardiology, Taipei (China); Chen, Yen-Kung [Shin Kong Wu-Ho Su Memorial Hospital, Department of Nuclear Medicine, Taipei (China); Hung, Guang-Uei [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Changhua (China); Wu, Tao-Cheng [National Yang-Ming University, Cardiovascular Research Center, Taipei (China)

    2017-01-15

    The aim of this study was to evaluate the accuracy of myocardial blood flow (MBF) quantitation of {sup 99m}Tc-Sestamibi (MIBI) single photon emission computed tomography (SPECT) compared with {sup 13}N-Ammonia (NH3) position emission tomography (PET) on the same cohorts. Recent advances of SPECT technologies have been applied to develop MBF quantitation as a promising tool to diagnose coronary artery disease (CAD) for areas where PET MBF quantitation is not available. However, whether the SPECT approach can achieve the same level of accuracy as the PET approach for clinical use still needs further investigations. Twelve healthy volunteers (HVT) and 16 clinical patients with CAD received both MIBI SPECT and NH3 PET flow scans. Dynamic SPECT images acquired with high temporary resolution were fully corrected for physical factors and processed to quantify K1 using the standard compartmental modeling. Human MIBI tracer extraction fraction (EF) was determined by comparing MIBI K1 and NH3 flow on the HVT group and then used to convert flow values from K1 for all subjects. MIBI and NH3 flow values were systematically compared to validate the SPECT approach. The human MIBI EF was determined as [1.0-0.816*exp(-0.267/MBF)]. Global and regional MBF and myocardial flow reserve (MFR) of MIBI SPECT and NH3 PET were highly correlated for all subjects (global R{sup 2}: MBF = 0.92, MFR = 0.78; regional R{sup 2}: MBF ≥ 0.88, MFR ≥ 0.71). No significant differences for rest flow, stress flow, and MFR between these two approaches were observed (All p ≥ 0.088). Bland-Altman plots overall revealed small bias between MIBI SPECT and NH3 PET (global: ΔMBF = -0.03Lml/min/g, ΔMFR = 0.07; regional: ΔMBF = -0.07 - 0.06, ΔMFR = -0.02 - 0.22). Quantitation with SPECT technologies can be accurate to measure myocardial blood flow as PET quantitation while comprehensive imaging factors of SPECT to derive the variability between these two approaches were fully addressed and corrected

  13. SPECT myocardial blood flow quantitation toward clinical use: a comparative study with "1"3N-Ammonia PET myocardial blood flow quantitation

    International Nuclear Information System (INIS)

    Hsu, Bailing; Hu, Lien-Hsin; Yang, Bang-Hung; Ting, Chien-Hsin; Huang, Wen-Sheng; Chen, Lung-Ching; Chen, Yen-Kung; Hung, Guang-Uei; Wu, Tao-Cheng

    2017-01-01

    The aim of this study was to evaluate the accuracy of myocardial blood flow (MBF) quantitation of "9"9"mTc-Sestamibi (MIBI) single photon emission computed tomography (SPECT) compared with "1"3N-Ammonia (NH3) position emission tomography (PET) on the same cohorts. Recent advances of SPECT technologies have been applied to develop MBF quantitation as a promising tool to diagnose coronary artery disease (CAD) for areas where PET MBF quantitation is not available. However, whether the SPECT approach can achieve the same level of accuracy as the PET approach for clinical use still needs further investigations. Twelve healthy volunteers (HVT) and 16 clinical patients with CAD received both MIBI SPECT and NH3 PET flow scans. Dynamic SPECT images acquired with high temporary resolution were fully corrected for physical factors and processed to quantify K1 using the standard compartmental modeling. Human MIBI tracer extraction fraction (EF) was determined by comparing MIBI K1 and NH3 flow on the HVT group and then used to convert flow values from K1 for all subjects. MIBI and NH3 flow values were systematically compared to validate the SPECT approach. The human MIBI EF was determined as [1.0-0.816*exp(-0.267/MBF)]. Global and regional MBF and myocardial flow reserve (MFR) of MIBI SPECT and NH3 PET were highly correlated for all subjects (global R"2: MBF = 0.92, MFR = 0.78; regional R"2: MBF ≥ 0.88, MFR ≥ 0.71). No significant differences for rest flow, stress flow, and MFR between these two approaches were observed (All p ≥ 0.088). Bland-Altman plots overall revealed small bias between MIBI SPECT and NH3 PET (global: ΔMBF = -0.03Lml/min/g, ΔMFR = 0.07; regional: ΔMBF = -0.07 - 0.06, ΔMFR = -0.02 - 0.22). Quantitation with SPECT technologies can be accurate to measure myocardial blood flow as PET quantitation while comprehensive imaging factors of SPECT to derive the variability between these two approaches were fully addressed and corrected. (orig.)

  14. Brain SPECT using dipyridamole for evaluation of vascular reserve

    International Nuclear Information System (INIS)

    Kim, Su Zy; Park, Chan Hee; Yoon, Soo Hwan; Pai, Moon Sun; Yoon, Suk Nam; Cho, Kyung Kee

    1997-01-01

    Baseline and stress brain SPECT studies using CO 2 inhalation, acetazolamide (Diamox R ) and adenosine administrations have been used in the evaluation of cerebral vascular reserve. Recently dipyridamole (Persantine R ) which is one of the pharmacologic myocardial perfusion SPECT agents as a potent vasodilator is suggested as another cerebral vasodilator. IV Diamox R is not available in Korea. Therefore, the purpose of our study was to evaluate dipyridamole in stress brain SPECT in patients with Moya Moya disease. Eight patients with angiographically proven Moya Moya disease were studied. Their ages ranged from 7 to 62 year old. There were 4 males and 4 females. Each patient had a baseline and persantine brain SPECT studies with 1 to 3 days' interval. Dipyridamole was given intravenously at a dose of 0.56 mg/kg over 4 minutes while watching vital signs such as blood pressure, heart rate, and electrocardiogram. Three minutes after the completion of the infusion, 99mTc-ECD (0.2 mCi/Ib body weight) was injected. Brain SPECT was performed 30 minutes later using a tripple head gamma camera equipped with LEHR collimators. A total of 128 projections with an acquisition time of 30 second per projection was obtained and reconstructed by filtered back projections without attenuation correction. The difference between the baseline and persantine studies was analysed by visual and semiquantitavely. During the infusion of persantine, heart rate, blood pressure and side effects such as headache, chest discomfort were similar to the persantine myocardial SPECT studies. Five of eight patients showed a significant decrease in rCBF on persantine brain SPECT in comparison to the baseline study. The remaining three revealed no significant change in rCBF. Our study suggests that the dipyridamole stress brain SPECT is feasible and useful in assessing cerebral blood flow reserve. However we need to evaluate more number of patients in the future

  15. Simultaneous thallium-201/technetium-99m pyrophosphate tomography in patients with acute myocardial infarction: comparison of rotational SPECT and seven pinhole tomography

    International Nuclear Information System (INIS)

    Krause, T.; Schuemichen, C.; Beck, A.; Moser, E.; Zeiher, A.

    1992-01-01

    Simultaneous Tl-201/Tc-99m pyrophosphate (PPi) tomography was compared to Tc-99m PPi tomography and rotational SPECT (SPECT) was compared to seven pinhole tomography (9-PHT), respectively, in 19 patients with acute myocardial infarction (AMI). The results were correlated to electrocardiographic and angiographic findings. With Tl-201/Tc-99, PPi, all infarctions were detected and site of infarction was determined, independent of the tomographic technique used. There was no significant difference between the two acquisition techniques 7-PHT and SPECT concerning spatial extent of Tc-99m PPi accumulation and the uptake ratio. However, using only Tc-99m PPi without Tl-201 as anatomical marker, SPECT detected 15/19 infarctions. In 7 of these 15 cases infarction site was correctly determined. 7-PHT detected 11/19 and site was correctly determined in 9/11 infarctions. Myocardial infarctions which failed diagnosis using Tc-99m PPi alone showed significantly smaller spatial extent of Tc-99m PPi accumulation and necrosis to blood pool ratio was lower as assessed by Tl201/Tc-99m PPi tomography. In conclusions, tomography using simultaneous Tl-201/Tc-99m PPi imaging is a reliable technique for diagnosis and localization of AMI. For this reason, results obtained with SPECT and 7-PHT are comparable. Independent of the tomographic technique used, combined imaging is superior to Tc-99m PPi alone without Tl-201 as additional anatomical marker (orig./MG) [de

  16. Regional cerebral blood flow in Parkinson's disease by [sup 123]I-IMP SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kitamura, Yoshihiro [Okayama Univ. (Japan). School of Medicine

    1994-06-01

    Regional cerebral blood flow (rCBF) was evaluated in 63 patients with Parkinson's disease (PD) by single-photon emission computed tomography (SPECT) using N-isopropyl-p-[sup 123]I-iodoamphetamine ([sup 123]I-IMP) as a tracer. Evaluation of the SPECT images was performed in accordance with the rCBF quantification method using a microsphere model. Patients in stage IV demonstrated significantly lower rCBF than those in stage II at the frontal, temporal, parietal, occipital regions and in the thalamus and cerebellum. Subjects with mental symptoms demonstrated decreased rCBF in every region in the brain. The present study indicates that clinical exacerbation and manifestation of dementia and other psychiatric symptoms in Parkinson's disease are associated with decreased blood flow in various brain regions. (author).

  17. Comparison of SPECT bone scintigraphy with MRI for diagnosis of meniscal tears

    International Nuclear Information System (INIS)

    Tahmasebi, Mohammad-naghi; Saghari, Mohsen; Moslehi, Masoud; Gholamrezanezhad, Ali

    2005-01-01

    Scintigraphy has been considered as competitive to MRI, but limited data are available on the accuracy of single photon emission tomography (SPECT) compared with MRI for the assessment of meniscal tears. Our objective was to assess the value of SPECT in comparison to MRI. Between January 2003 and March 2004, sixteen patients were studied with both modalities and the accuracy rates of SPECT scan results, and MRI findings in the diagnosis of meniscal tears were compared. Arthroscopy was the gold standard. The respective sensitivity rate, specificity rate, and positive and negative predictive accuracies of MRI were 89%, 94%, 93%, and 79% and for SPECT those were 78%, 94%, 94%, and 88%. There was good agreement on the presence or absence of tears between two modalities (κ statistic = 0.699). SPECT and MRI are both valuable imaging techniques. SPECT is a useful alternative when MRI is unavailable or unsuitable and it is beneficial when more possible accuracy is desired (such as when MRI results are either inconclusive or conflict with other clinical data)

  18. 123I-iomazenil brain receptor SPECT in focal epilepsy. In comparison with 99mTc-HMPAO brain SPECT, MRI and Video/EEG monitoring

    International Nuclear Information System (INIS)

    Xu Hao; Wang Tongge; Huang Li; Michael Cordes

    1998-01-01

    Purpose: To evaluate the clinical value of 123 I-Iomazenil brain receptor SPECT in diagnosis of focal epilepsy in comparison with 99m Tc-HMPAO brain SPECT, MRI and Video/EEG monitoring. Methods 123 I-Iomazenil brain receptor SPECT was performed on 40 patients with focal epilepsy. The results were compared with those obtained by 99m Tc-HMPAO brain SPECT, MRI and Video/EEG monitoring. Results: In 40 patients, the sensitivity of Video/EEG monitoring for localization of epileptogenic area was 95% (38/40). The sensitivity of 123 I-iomazenil brain receptor SPECT, 99m Tc-HMPAO brain SPECT and MRI for localization of epileptogenic area compared with Video/EEG monitoring ('gold standard') was 65.8%(25/38), 55.3%(21/38) and 47.4%(18/38), respectively. The localization of epileptogenic area with 123 I-Iomazenil brain receptor SPECT was in concordance with Video/EEG monitoring in 20 patients, 99m Tc-HMPAO brain SPECT in 15 patients and MRI in 16 patients, respectively. The sensitivity of 123 I-Iomazenil brain receptor SPECT combined with MRI for localization of epileptogenic area was 84.2%(32/38). Conclusions: 123 I-Iomazenil brain receptor SPECT is a useful method in detecting and localizing epileptogenic area. The combination of 123 I-Iomazenil brain receptor SPECT and MRI has a high sensitivity for detecting epileptogenic area

  19. Comparison of automatic quantification software for the measurement of ventricular volume and ejection fraction in gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Van Staden, J.A.; Herbst, C.P.; Du Raan, H.; Lotter, M.G.; Otto, A.C.

    2004-01-01

    Full text: Introduction: Gated myocardial perfusion SPECT has been used to calculate left ventricular ejection fraction (LVEF) and left ventricular end-diastolic volume (LVEDV) and has correlated well with conventional methods. However, the comparative accuracy of and correlations across various types of gated SPECT software are not well understood. Materials and methods: Twelve patients participated in a radionuclide gated blood-pool (GBP) study in addition to undergoing 99m Tc-sestamibi gated SPECT. Three different software algorithms, Quantitative Gated SPECT (QGS) from Cedars-Sinai, MultiDim from Stanford University Medical School and GQUANT from Alfa Nuclear were used to compute LVEF and LVEDV. These software algorithms operate in 3-dimensional space, two dependent on surface detection and the other on statistical parameters. The LVEF as calculated from gated SPECT myocardial perfusion images were compared with LVEF calculated from the GBP studies in the same patients to assess accuracy of the three software algorithms. Results: The software success-rate was 92% (11/12 pts) for MultiDim and 100% for the QGS and GQUANT. Agreement between LVEF measured with MultiDim and QGS, MultiDim and GQUANT and QGS and GQUANT were excellent (LVEF-MuItidim 0.80 LVEF QGS +5.02, r = 0.93, LVEF GQUANT = 1.10 LVEF MuItidim -1.33, r 0.90 and LVEF GQUANT = 1.02 LVEF QGS -1.40, r = 0.96). The correlation coefficient for LVEF between gated SPECT and the GBP study was 0.95, 0.95 and 0.97, for MultiDim, GQUANT and QGS, respectively. Conclusion: All 3 software programs showed good correlation between LVEF for gated SPECT and the GBP study. Good agreement for LVEF was observed also between the three software algorithms. However, because each method has unique characteristics that depend on its specific algorithm and thus behaves differently in the various patients, the methods should not be used interchangeably. (author)

  20. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies

    Science.gov (United States)

    Winant, Celeste D.; Aparici, Carina Mari; Zelnik, Yuval R.; Reutter, Bryan W.; Sitek, Arkadiusz; Bacharach, Stephen L.; Gullberg, Grant T.

    2012-01-01

    Computer simulations, a phantom study and a human study were performed to determine whether a slowly rotating single-photon computed emission tomography (SPECT) system could provide accurate arterial input functions for quantification of myocardial perfusion imaging using kinetic models. The errors induced by data inconsistency associated with imaging with slow camera rotation during tracer injection were evaluated with an approach called SPECT/P (dynamic SPECT from positron emission tomography (PET)) and SPECT/D (dynamic SPECT from database of SPECT phantom projections). SPECT/P simulated SPECT-like dynamic projections using reprojections of reconstructed dynamic 94Tc-methoxyisobutylisonitrile (94Tc-MIBI) PET images acquired in three human subjects (1 min infusion). This approach was used to evaluate the accuracy of estimating myocardial wash-in rate parameters K1 for rotation speeds providing 180° of projection data every 27 or 54 s. Blood input and myocardium tissue time-activity curves (TACs) were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K1. For the second method (SPECT/D), an anthropomorphic cardiac torso phantom was used to create real SPECT dynamic projection data of a tracer distribution derived from 94Tc-MIBI PET scans in the blood pool, myocardium, liver and background. This method introduced attenuation, collimation and scatter into the modeling of dynamic SPECT projections. Both approaches were used to evaluate the accuracy of estimating myocardial wash-in parameters for rotation speeds providing 180° of projection data every 27 and 54 s. Dynamic cardiac SPECT was also performed in a human subject at rest using a hybrid SPECT/CT scanner. Dynamic measurements of 99mTc-tetrofosmin in the myocardium were obtained using an infusion time of 2 min. Blood input, myocardium tissue and liver TACs were estimated using the same spatiotemporal splines. The spatiotemporal maximum

  1. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies

    International Nuclear Information System (INIS)

    Winant, Celeste D; Aparici, Carina Mari; Bacharach, Stephen L; Gullberg, Grant T; Zelnik, Yuval R; Reutter, Bryan W; Sitek, Arkadiusz

    2012-01-01

    Computer simulations, a phantom study and a human study were performed to determine whether a slowly rotating single-photon computed emission tomography (SPECT) system could provide accurate arterial input functions for quantification of myocardial perfusion imaging using kinetic models. The errors induced by data inconsistency associated with imaging with slow camera rotation during tracer injection were evaluated with an approach called SPECT/P (dynamic SPECT from positron emission tomography (PET)) and SPECT/D (dynamic SPECT from database of SPECT phantom projections). SPECT/P simulated SPECT-like dynamic projections using reprojections of reconstructed dynamic 94 Tc-methoxyisobutylisonitrile ( 94 Tc-MIBI) PET images acquired in three human subjects (1 min infusion). This approach was used to evaluate the accuracy of estimating myocardial wash-in rate parameters K 1 for rotation speeds providing 180° of projection data every 27 or 54 s. Blood input and myocardium tissue time-activity curves (TACs) were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K 1 . For the second method (SPECT/D), an anthropomorphic cardiac torso phantom was used to create real SPECT dynamic projection data of a tracer distribution derived from 94 Tc-MIBI PET scans in the blood pool, myocardium, liver and background. This method introduced attenuation, collimation and scatter into the modeling of dynamic SPECT projections. Both approaches were used to evaluate the accuracy of estimating myocardial wash-in parameters for rotation speeds providing 180° of projection data every 27 and 54 s. Dynamic cardiac SPECT was also performed in a human subject at rest using a hybrid SPECT/CT scanner. Dynamic measurements of 99m Tc-tetrofosmin in the myocardium were obtained using an infusion time of 2 min. Blood input, myocardium tissue and liver TACs were estimated using the same spatiotemporal splines. The spatiotemporal

  2. Regional cerebral blood flow in status epileptics measured by single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Ichiseki, Hajime; Terashi, Akiro; Hamamoto, Makoto; Miyazaki, Tokuzo.

    1995-01-01

    We have performed single photon emission computed tomography (SPECT) with 99m Tc-hexamethylpropylene amineoxime (HM-PAO) to evaluate regional cerebral blood flow (rCBF) in status epileptics (SE) caused by a cerebral vascular accident. In addition, we have discussed the neurophysiology of SE based on the SPECT findings. A total of sixteen patients (5 males and 11 females, average age; 78.2 years old) with SE who were suffering from prolonged consciousness disturbance were investigated. When SPECT was performed in the ictal state, there was a remarkable increase in radio isotope (RI) uptake at the focus which correlated well with EEG findings. However, in other cortical regions, basal ganglia and thalamus, there was a relatively demonstrated decrease in RI uptake compared with that of the focus. Additionally in the interictal state, we found a decrease in RI uptake in the epileptic foci and normal recovery of the RI uptake level in other cerebral regions. We speculate that these characteristic patterns of cerebral blood flow distribution shown by SPECT scans in the ictal state reflect the state of consciousness disturbance due to SE. In general, in the elderly, it is difficult to make a differential diagnosis between prolonged consciousness disturbance due to nonconvulsive SE and other diseases such as cardiovascular diseases, dehydration, metabolic disorder, etc. Nevertheless, nonconvulsive SE causes diffuse cell loss and irreversible brain damage. Therefore the elderly who have suffered from prolonged consciousness disturbance due to SE need an exact diagnosis and immediate medical treatment. When we diagnose a nonconvulsive SE, the characteristic findings of SPECT scans in the ictal state are very clear and useful. In conclusion, SPECT is a very simple and non-invasive method that demonstrates abnormalities of brain function exactly. Therefore, we should perform not only EEC but also SPECT scans when making a diagnosis of SE. (author)

  3. Regional cerebral blood flow in status epileptics measured by single photon emission computed tomography (SPECT)

    Energy Technology Data Exchange (ETDEWEB)

    Ichiseki, Hajime; Terashi, Akiro [Nippon Medical School, Tokyo (Japan); Hamamoto, Makoto; Miyazaki, Tokuzo

    1995-12-01

    We have performed single photon emission computed tomography (SPECT) with {sup 99m}Tc-hexamethylpropylene amineoxime (HM-PAO) to evaluate regional cerebral blood flow (rCBF) in status epileptics (SE) caused by a cerebral vascular accident. In addition, we have discussed the neurophysiology of SE based on the SPECT findings. A total of sixteen patients (5 males and 11 females, average age; 78.2 years old) with SE who were suffering from prolonged consciousness disturbance were investigated. When SPECT was performed in the ictal state, there was a remarkable increase in radio isotope (RI) uptake at the focus which correlated well with EEG findings. However, in other cortical regions, basal ganglia and thalamus, there was a relatively demonstrated decrease in RI uptake compared with that of the focus. Additionally in the interictal state, we found a decrease in RI uptake in the epileptic foci and normal recovery of the RI uptake level in other cerebral regions. We speculate that these characteristic patterns of cerebral blood flow distribution shown by SPECT scans in the ictal state reflect the state of consciousness disturbance due to SE. In general, in the elderly, it is difficult to make a differential diagnosis between prolonged consciousness disturbance due to nonconvulsive SE and other diseases such as cardiovascular diseases, dehydration, metabolic disorder, etc. Nevertheless, nonconvulsive SE causes diffuse cell loss and irreversible brain damage. Therefore the elderly who have suffered from prolonged consciousness disturbance due to SE need an exact diagnosis and immediate medical treatment. When we diagnose a nonconvulsive SE, the characteristic findings of SPECT scans in the ictal state are very clear and useful. In conclusion, SPECT is a very simple and non-invasive method that demonstrates abnormalities of brain function exactly. Therefore, we should perform not only EEC but also SPECT scans when making a diagnosis of SE. (author).

  4. Investigation of normal pressure hydrocephalus by sup 123 I-IMP SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kamiya, Ken; Yamashita, Nobuko; Nagai, Hajime [Nagoya City Univ. (Japan). Faculty of Medicine; Mizawa, Ikuo

    1991-08-01

    We evaluated N-isopropyl-p-({sup 123}I) iodoamphetamine ({sup 123}I-IMP) single photon emission computed tomography (SPECT) as a method for identifying normal pressure hydrocephalic (NPH) patients eligible for shunting procedures. {sup 123}I-IMP SPECT scans were taken before and after cerebrospinal fluid (CSF) taps in NPH cases. Post-subarachnoid hemorrhagic (SAH) patients showed apparent frontal blood flow reduction but non-SAH cases did not. The frontal blood flow increased in comparison with the temporal flow after CSF tapping in SAH cases who benefited most from shunting. Cerebral blood flow study before and after CSF removal is a potential method for classifying NPH patients likely to benefit from the shunting operation. (author).

  5. Equilibrium blood pool scanning in the evaluation of hemophilic arthropathy

    International Nuclear Information System (INIS)

    Spies, S.; Green, D.; Rana, N.A.; Milgram, J.W.; Mintzer, R.

    1978-01-01

    Arthropathy was evaluated in six patients with severe hemophilia (factor VIII<1%) using the technique of blood pool scanning. Employing an in vivo method for erythrocyte labelling with technetium-99m, a dynamic perfusion sequence was obtained using a scintillation camera over the joint(s) to be examined. Subsequently, equilibrium blood pool images of the joints were obtained to determine regional blood volume. In young patients with repeated episodes of acute hemarthrosis, increased vascularity and increased blood pool in the affected joints were demonstrated. In older patients with fixed, contracted joints and degenerative arthropathy, vascularity and regional blood volume were not abnormal. Blood pool scanning is a safe, non-invasive technique that augments the clinical and radiographic examination of the joints. The method is helpful in distinguishing acute joint bleeding from chronic synovitis and arthritis, and may prove useful in selecting patients for synovectomy. (author)

  6. Analysis of cognitive function and regional cerebral blood flow in Parkinson's disease by 123I-IMP SPECT

    International Nuclear Information System (INIS)

    Kato, Takayuki; Morohoshi, Toshio; Hasegawa, Yukihiro; Fukui, Toshiya; Kawamura, Mitsuru; Sugita, Koujiro

    2000-01-01

    Several studies have found that the uptake of a radioisotope is reduced in the frontal or parietooccipital lobe on SPECT scans of patients with Parkinson's disease accompanied by cognitive impairment. The present study investigated the relationship between the results of SPECT imaging and those of cognitive function tests in patients with Parkinson's disease accompanied by cognitive impairment. Thirty patients with Parkinson's disease served as subjects, including 9 men and 21 women with an average of 66.1 years. Patients underwent 123 I-IMP SPECT and various cognitive function tests (Japanese alphabet pick-up test, Stroop test, Hasegawa's dementia screening scale, Raven color matrix, and course cube-combination test). Next, three neurologists with no knowledge of the patient's clinical symptoms were asked to analyze the reduced uptake on SPECT scans as follows: frontal lobe, parietooccipital lobe, frontal and parietooccipital lobes, diffused reduction, and no reduced uptake. The results of SPECT imaging and each cognitive function test were compared. Reduced uptake in the frontal and parietooccipital lobes and diffused reduction correlated with decreases in cognitive function. Cognitive impairment is not notable when cortical blood flow is partially reduced, but is notable when cortical blood flow is widely reduced. (author)

  7. The Aomori Prefecture Brain Blood Flow SPECT Phantom Study (First information). Comparison between reference image and each facility to aim at grasp of the situation

    International Nuclear Information System (INIS)

    Ishikura, Makihito; Narita, Kazuo; Terayama, Yoshio; Kudou, Sukehiro

    2008-01-01

    As the single photon emission computed tomography (SPECT) image has rather big between-facility and -machine differences, a questionnaire was done to 18 SPECT facilities in Aomori Prefecture in May, 03, 15 of which answered, for the purpose of standardization of the brain blood flow images in the prefecture. The questionnaire concerned the condition of data collection, image display and reconstruction, and quantitative analysis, based on whose results the Phantom Study was then conducted to see the relationship between the average count and Butterworth filter (BWF) cut-off value by comparison of reference and facilities' images. The gamma camera PRISM 200XP, processor Odyssey Fx and low-energy high-resolution (LEHR) collimator were used for the reference image with collection matrix 128 x 128, 3.5 mm pixel size, Ramp reconstruction filter, Chang decay correction (coefficient μ=0.09) and null scattering correction. Used was the Hoffman phantom containing 30-37 MBq of 99m Tc or 8-18 MBq of 123 I. It was found that the fluctuation of cut-off values became small depending on the increase of count and the collection count was low for both nuclides in those facilities, and thus further study of the measure for increasing the collection count was thought necessary. (R.T.)

  8. Presentation of regional cerebral blood flow in amphetamine abusers by 99Tcm-HMPAO brain SPECT

    International Nuclear Information System (INIS)

    Kao, C.H.; Wang, S.J.; Yeh, S.H.

    1994-01-01

    The aim of this study was to describe the effectiveness of 99 Tc m -hexamethylpropyleneamine oxime ( 99 Tc m -HMPAO) brain single photon emission computed tomography (SPECT) in the assessment of the regional cerebral blood flow (rCBF) in amphetamine abusers. Twenty-one amphetamine abusers were included and 99 Tc m -HMPAO brain SPECT performed to evaluate rCBF. The drug-using periods ranged from 1 month to several years. The demonstrated neuropsychogenic symptoms and signs of the abusers were from normal presentation to various neurologic complications. The brain SPECT scans were interpreted visually as either normal or abnormal. The degree of abnormality was classified into mild or severe. The results revealed that (a) most SPECT studies in abusers show small defects (95%, 20/21 cases); 71% (15/21) of cases revealed multiple defects over both hemispheres (classified as severe); 24% (5/21) of the cases had focal defects (classified as mild); and only one case (5%, 1/21) demonstrated a normal SPECT finding; (b) the degree of abnormality on SPECT scans was not related to the dose and duration of drug use or the severity of the neuropsychiatric symptoms and signs. In conclusion, 99 Tc m -HMPAO brain SPECT is a sensitive but not specific test for neuropsychogenic abnormalities associated with amphetamine abuse. (Author)

  9. The influence of gravity on regional lung blood flow in humans: SPECT in the upright and head-down posture.

    Science.gov (United States)

    Ax, M; Sanchez-Crespo, A; Lindahl, S G E; Mure, M; Petersson, J

    2017-06-01

    Previous studies in humans have shown that gravity has little influence on the distribution of lung blood flow while changing posture from supine to prone. This study aimed to evaluate the maximal influence of posture by comparison of regional lung blood flow in the upright and head-down posture in 8 healthy volunteers, using a tilt table. Regional lung blood flow was marked by intravenous injection of macroaggregates of human albumin labeled with 99m Tc or 113m In, in the upright and head-down posture, respectively, during tidal breathing. Both radiotracers remain fixed in the lung after administration. The distribution of radioactivity was mapped using quantitative single photon emission computed tomography (SPECT) corrected for attenuation and scatter. All images were obtained supine during tidal breathing. A shift from upright to the head-down posture caused a clear redistribution of blood flow from basal to apical regions. We conclude that posture plays a role for the distribution of lung blood flow in upright humans, and that the influence of posture, and thereby gravity, is much greater in the upright and head-down posture than in horizontal postures. However, the results of the study demonstrate that lung structure is the main determinant of regional blood flow and gravity is a secondary contributor to the distribution of lung blood flow in the upright and head-down positions. NEW & NOTEWORTHY Using a dual-isotope quantitative SPECT method, we demonstrated that although a shift in posture redistributes blood flow in the direction of gravity, the results are also consistent with lung structure being a greater determinant of regional blood flow than gravity. To our knowledge, this is the first study to use modern imaging methods to quantify the shift in regional lung blood flow in humans at a change between the upright and head-down postures. Copyright © 2017 the American Physiological Society.

  10. Analysis of Regional Cerebral Blood Flow Using 99mTc-HMPAO Brain SPECT in Senile Dementia of Alzheimer Type

    International Nuclear Information System (INIS)

    Lee, Myung Hae; Lee, Myung Chul; Koh, Chang Soon; Roh, Jae Kyu; Woo, Chong In

    1988-01-01

    99m Tc-HMPAO brain SPECT studies were performed in 11 patients with Alzheimer's disease, 7 patients with psychological depression and 12 normal controls. Changes of regional cerebral blood flow was semiquantitatively analyzed and the results were as follows. 1) In 11 patients with Alzheimer's disease, significant reduction of regional cerebral blood flow was found In both temporoparietal areas. 2) Relative perfusion between cerebral hemispheres was rather symmetrical in patient with Alzheimer's disease. 3) All patients with depression showed normal SPECT findings. As for conclusion, 99m Tc-HMPAO brain SPECT seemed to be a valuable method for clinical assessment and management of patients with Alzheimer's disease.

  11. Regional cerebral blood flow in Parkinson's disease measured with N-isopropyl-p-[123I]iodoamphetamine (IMP) SPECT

    International Nuclear Information System (INIS)

    Odano, Ikuo; Nishihara, Mamiko; Hayashi, Hiroko; Higuchi, Shoichi; Sakai, Kunio; Ishikawa, Atsushi; Ibayashi, Katsuhiko.

    1992-01-01

    N-isopropyl-p-[ 123 I]iodoamphetamine (IMP) SPECT studies were performed on 21 patients (13 females; 45-73 yrs) with idiopathic Parkinson's disease (PD) and 10 age-matched normal controls (39-69 yrs). Regional cerebral blood flow (rCBF) was quantitatively measured by the arterial blood sampling method. When compared with normal controls, global CBF, and rCBF in the frontal cortex and in the basal ganglia were reduced 22.1% (p 123 I-IMP SPECT imaging is useful for evaluation and follow-up of patients with PD. (author)

  12. Magnetic resonance angiography with blood-pool contrast agents: future applications

    International Nuclear Information System (INIS)

    Fink, C.; Goyen, M.; Lotz, J.

    2007-01-01

    Blood pool agents remain in the intravascular space for a longer time period. Therefore the optimal imaging window for vascular structures is widened to about 30 minutes. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first blood-pool contrast agent approved in Europe for contrast-enhanced magnetic resonance angiography (MRA) of vessels in the abdomen, pelvis and lower extremity in adults. Other possible applications of blood-pool agents are now being considered, such as assessment of venous thromboembolism, coronary artery disease or sinus venous thrombosis. Perfusion MR imaging holds promise for detecting lung perfusion defects with higher spatial resolution and reduced scan time compared with radionuclide scintigraphy. In coronary artery disease, blood-pool agents enable a substantial increase in the quality of coronary artery imaging. Quantitative myocardial perfusion and myocardial viability seem to be possible, although modifications in protocols and sequence design are necessary for optimal results. Other novel applications of blood-pool agents include monitoring of inflammatory changes in systemic lupus erythematosus and evaluation of tumour invasion into lymph nodes and more reliable assessment of cerebral venous and sinus thrombosis. (orig.)

  13. Magnetic resonance angiography with blood-pool contrast agents: future applications

    Energy Technology Data Exchange (ETDEWEB)

    Fink, C. [Univ. Hospitals, Grosshadern, Munich (Germany); Goyen, M. [Univ. Medical Center, Hamburg-Eppendorf, Hamburg (Germany); Lotz, J. [Hannover Medical School, Hannover (Germany)

    2007-03-15

    Blood pool agents remain in the intravascular space for a longer time period. Therefore the optimal imaging window for vascular structures is widened to about 30 minutes. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first blood-pool contrast agent approved in Europe for contrast-enhanced magnetic resonance angiography (MRA) of vessels in the abdomen, pelvis and lower extremity in adults. Other possible applications of blood-pool agents are now being considered, such as assessment of venous thromboembolism, coronary artery disease or sinus venous thrombosis. Perfusion MR imaging holds promise for detecting lung perfusion defects with higher spatial resolution and reduced scan time compared with radionuclide scintigraphy. In coronary artery disease, blood-pool agents enable a substantial increase in the quality of coronary artery imaging. Quantitative myocardial perfusion and myocardial viability seem to be possible, although modifications in protocols and sequence design are necessary for optimal results. Other novel applications of blood-pool agents include monitoring of inflammatory changes in systemic lupus erythematosus and evaluation of tumour invasion into lymph nodes and more reliable assessment of cerebral venous and sinus thrombosis. (orig.)

  14. Value of blood-pool subtraction in cardiac indium-111-labeled platelet imaging

    Energy Technology Data Exchange (ETDEWEB)

    Machac, J.; Vallabhajosula, S.; Goldman, M.E.; Goldsmith, S.J.; Palestro, C.; Strashun, A.; Vaquer, R.; Phillips, R.A.; Fuster, V. (Mt. Sinai Medical Center, New York, NY (USA))

    1989-09-01

    Blood-pool subtraction has been proposed to enhance {sup 111}In-labeled platelet imaging of intracardiac thrombi. We tested the accuracy of labeled platelet imaging, with and without blood-pool subtraction, in ten subjects with cardiac thrombi of varying age, eight with endocarditis being treated with antimicrobial therapy and ten normal controls. Imaging was performed early after labeled platelet injection (24 hr or less) and late (48 hr or more). Blood-pool subtraction was carried out. All images were graded subjectively by four experienced, blinded readers. Detection accuracy was measured by the sensitivity at three fixed levels of specificity estimated from receiver operator characteristic curve analysis and tested by three-way analysis of variance. Detection accuracy was generally improved on delayed images. Blood-pool subtraction did not improve accuracy. Although blood-pool subtraction increased detection sensitivity, this was offset by decreased specificity. For this population studied, blood-pool subtraction did not improve subjective detection of abnormal platelet deposition by 111In platelet imaging.

  15. Value of blood-pool subtraction in cardiac indium-111-labeled platelet imaging

    International Nuclear Information System (INIS)

    Machac, J.; Vallabhajosula, S.; Goldman, M.E.; Goldsmith, S.J.; Palestro, C.; Strashun, A.; Vaquer, R.; Phillips, R.A.; Fuster, V.

    1989-01-01

    Blood-pool subtraction has been proposed to enhance 111 In-labeled platelet imaging of intracardiac thrombi. We tested the accuracy of labeled platelet imaging, with and without blood-pool subtraction, in ten subjects with cardiac thrombi of varying age, eight with endocarditis being treated with antimicrobial therapy and ten normal controls. Imaging was performed early after labeled platelet injection (24 hr or less) and late (48 hr or more). Blood-pool subtraction was carried out. All images were graded subjectively by four experienced, blinded readers. Detection accuracy was measured by the sensitivity at three fixed levels of specificity estimated from receiver operator characteristic curve analysis and tested by three-way analysis of variance. Detection accuracy was generally improved on delayed images. Blood-pool subtraction did not improve accuracy. Although blood-pool subtraction increased detection sensitivity, this was offset by decreased specificity. For this population studied, blood-pool subtraction did not improve subjective detection of abnormal platelet deposition by 111In platelet imaging

  16. HMPAO-SPECT in cerebral seizures

    International Nuclear Information System (INIS)

    Gruenwald, F.; Bockisch, A.; Reichmann, K.; Ammari, B.; Hotze, A.; Biersack, H.J.; Durwen, H.; Buelau, P.; Elger, C.E.; Rohde, A.; Penin, H.

    1988-01-01

    In nine patients with suspected psychogenic seizures and in three patients with proven epileptic seizures HMPAO-SPECT was performed prior to and during seizure. In the patients with lateron-proven psychogenic seizures no, or only slight, changes of regional cerebral blood flow were found. Patients with proven epilepsy revealed partly normal findings interictally but during seizure a markedly increased circumscript blood flow was found in all patients. Even though PET is superior to SPECT with respect to spatial resolution, in the diagnosis of seizures HMPAO-SPECT has the advantage of enabling injection of the tracer during the seizure and the performance of the SPECT study subsequently. (orig.) [de

  17. Advance prediction of mild cognitive impairment (MCI) using 99mTc-ECD SPECT brain blood flow imaging

    International Nuclear Information System (INIS)

    Kawasaki, Yohsuke

    2008-01-01

    Mild Cognitive Impairment (MCI) is considered as a precursor state of Alzheimer disease (AD). Single photon emission computed tomography (SPECT) brain blood flow imaging was investigated in MCI and it's relevance to the prognosis of MCI was evaluated in an attempt define the characteristics of brain blood flow imaging of MCI (amnestic MCI; aMCI) converting to AD. Ninety-two patients over 60 years old with amnesia were studied. 99m Tc-ethyl cysteinate dimer (ECD) SPECT brain blood flow examinations of the subject under drug-free conditions were conducted and imaging was analyzed according to the first clinical diagnosis. Patients given a diagnosis of MCI on the first clinical diagnosis, were examined again after 2 years and the SPECT imaging before 2 years previously was classified and analyzed. Of them, there were 35 MCI patients, converting of 13 AD patients (37.1%; aMCI), 10 MCI patients (28.6%; non-converter), 4 depression patients (11.4%; Depression type MCI (dMCI)), 1 Geriatric psychosis patient, but 7 patients dropped out. In the aMCI group, relative hypoperfusion was recognized in the posterior cingulate and the precuneus. In the dMCI group, relative hypoperfusion was recognized in the dorsolateral prefrontal cortex (DLPFC) and the anterior cingulate. In the non-converter group, relative hypoperfusion was recognized in the basal forebrain. The hypoperfusion of the precuneus in aMCI, and the hypoperfusion of the right frontal lobe (DLPFC, dorsal-anterior cingulate) in dMCI were characteristic brain blood-flow abnormalities. We believe 99m Tc-ECD SPECT brain blood flow imaging to be useful in the diagnosis of aMCI and in the early detection of depression. (author)

  18. SPECT in psychiatry. SPECT in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Barocka, A. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany)); Feistel, H. (Nuklearmedizinische Klinik, Erlangen (Germany)); Ebert, D. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany)); Lungershausen, E. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany))

    1993-08-13

    This review presents Single Photon Emission Computed Tomography (SPECT) as a powerful tool for clinical use and research in psychiatry. Its focus is on regional cerebral blood flow, measured with technetium labelled HMPAO. In addition, first results with brain receptor imaging, concerning dopamin-D[sub 2] and benzodiazepine receptors, are covered. Due to major improvements in image quality, and impressive number of results has been accumulated in the past three years. The authors caution against using SPECT results as markers for disease entities. A finding like 'hypofrontality' is considered typical of a variety of mental disorders. Clearly both, more experience with SPECT and contributions from psychopathology, are needed. (orig.)

  19. In vivo tomographic study of cerebral blood perfusion with SPECT in hemiparkinsonian monkeys

    International Nuclear Information System (INIS)

    Chen Shengdi; Xu Delong

    1994-01-01

    The authors present data on the utility of functional brain imaging with 99m Tc-ECD and SPECT in the study of MPTP induced hemiparkinsonism in monkeys. Injection of MPTP into the right common carotid artery of 10 rhesus monkeys produced hemiparkinsonism in the contralateral limbs which responded to antiparkinsonian medication. The unilateral neurotoxicity of the MPTP treated side was confirmed biochemically by marked reduction of DA contents in the nigrostriatum and histologically by selective neuronal loss in the substantia nigra. These monkeys with hemiparkinsonism were studied with SPECT using 99m Tc-ECD as perfusion marker. The results of brain scanning showed that the cerebral blood perfusion of MPTP treated side was significantly depleted 20∼90 days after MPTP intoxication, and returned to normal 8 months after perfusion. The experiment indicates that abnormal cerebral blood perfusion is involved in the course of parkinsonian pathophysiology

  20. Analysis of Regional Cerebral Blood Flow Using {sup 99m}Tc-HMPAO Brain SPECT in Senile Dementia of Alzheimer Type

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myung Hae; Lee, Myung Chul; Koh, Chang Soon; Roh, Jae Kyu; Woo, Chong In [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1988-03-15

    {sup 99m}Tc-HMPAO brain SPECT studies were performed in 11 patients with Alzheimer's disease, 7 patients with psychological depression and 12 normal controls. Changes of regional cerebral blood flow was semiquantitatively analyzed and the results were as follows. 1) In 11 patients with Alzheimer's disease, significant reduction of regional cerebral blood flow was found In both temporoparietal areas. 2) Relative perfusion between cerebral hemispheres was rather symmetrical in patient with Alzheimer's disease. 3) All patients with depression showed normal SPECT findings. As for conclusion, {sup 99m}Tc-HMPAO brain SPECT seemed to be a valuable method for clinical assessment and management of patients with Alzheimer's disease.

  1. Brain Perfusion SPECT Imaging in Sturge - Weber Syndrome : Comparison with MR Imaging

    International Nuclear Information System (INIS)

    Ryu, Jin Sook; Choi, Yun Young; Moon, Dae Hyuk; Yang, Seoung Oh; Ko, Tae Sung; Yoo, Shi Joon; Lee, Hee Kyung

    1996-01-01

    The purpose of this study was evaluate the characteristic perfusion changes in patients with Sturge-Weber syndrome by comparison of the findings of brain MR images and perfusion SPECT images. 99m Tc-HMPAO or 99m Tc-ECD interictal brain SPECTs were performed on 5 pediatric patients with Struge-Weber syndrome within 2 weeks after MR imaging. Brain SPECTs of three patients without calcification showed diminished perfusion in the affected area on MR image. A 3 month-old patient without brain atrophy or calcification demonstrated paradoxical hyperperfusion in the affected hemisphere, and follow-up perfusion SPECT revealed decreased perfusion in the same area. The other patient with advanced calcified lesion and atrophy on MR image showed diffusely decreased perfusion in the affected hemisphere, but a focal area of increased perfusion was also noted in the ipsilateral temporal lobe on SPECT. In conclusion, brain perfusion of the affected area of Sturge-Weber syndrome patients was usually diminished, but early or advanced patients may show paradoxical diffuse or focal hyperperfusion in the affected hemisphere. Further studies are needed for better understanding of these perfusion changes and pathophysiology of Struge-Weber syndrome.

  2. Functional assessment of the right ventricle with gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Wadhwa, S.S.; Abbati, D.; Carolan, M.

    2002-01-01

    Full text: Evaluation of right ventricular function can provide valuable information in a variety of cardiac and non-cardiac conditions. Functional assessment of the right ventricle is difficult owing to its anatomy and geometry. We describe a method of assessing right ventricular function using gated myocardial perfusion SPECT. In 20 patients right and left ventricular ejection fractions (RVEF, LVEF) were determined using gated blood pool (GBPS) and gated myocardial perfusion SPECT (GSPECT). To avoid contamination with right atrial activity the two frame method was adopted for gated blood pool data when measuring RVEF. In 9 patients with normal right ventricles, an index of wall thickening for the right ventricle was derived from the peak systolic and diastolic counts in the free wall. There was good linear correlation between the two methods adopted for calculation of LVEF and RVEF. Bland - Airman analysis demonstrated good agreement between the two methods with no specific bias. The mean LVEF was 47.9 +/-12% (GBPS) and 47.3 +/- 12.4 (GSPECT). The mean RVEF was 43.2 +/- 9.6% (GBPS) and 44.2 +/- 8.5% (GSPECT). In both cases the values were significantly different. The mean wall motion index was 35%. There was no correlation between the wall thickness index and ejection fraction however the index was greater in patients with normal right ventricle than in those with reduced RVER Gated SPECT offers an alternative to GBPS for the functional assessment of the right ventricle. Utilising GSPECT will allow the simultaneous assessment of both the right and left ventricles. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  3. Slower lower limb blood pooling in young women with orthostatic intolerance.

    Science.gov (United States)

    Lindenberger, Marcus; Länne, Toste

    2015-01-01

    What is the central question of this study? Orthostatic stress is mostly caused by venous blood pooling in the lower limbs. Venous distension elicits sympathetic responses, and increased distension speed enhances the cardiovascular response. We examine whether lower limb blood pooling rate during lower body negative pressure is linked to orthostatic intolerance. What is the main finding and its importance? A similar amount of blood was pooled in the lower limb, but at a slower rate in women who developed signs of orthostatic intolerance. The difference in blood pooling rate increased with orthostatic stress and was most prominent at a presyncope-inducing level of lower body negative pressure. The findings have implications for the pathophysiology as well as treatment of orthostatic intolerance. Vasovagal syncope is common in young women, but its aetiology remains elusive. Orthostatic stress-induced lower limb blood pooling is linked with central hypovolaemia and baroreceptor unloading. Venous distension in the arm elicits a sympathetic response, which is enhanced with more rapid distension. Our aim was to study both the amount and the speed of lower limb pooling during orthostatic stress and its effects on compensatory mechanisms to maintain cardiovascular homeostasis in women with orthostatic intolerance. Twenty-seven healthy women, aged 20-27 years, were subjected to a lower body negative pressure (LBNP) of 11-44 mmHg. Five women developed symptoms of vasovagal syncope (orthostatic intolerant) and were compared with the remaining women, who tolerated LBNP well (orthostatic tolerant). Lower limb blood pooling, blood flow and compensatory mobilization of venous capacitance blood were measured. Lower body negative pressure induced equal lower limb blood pooling in both groups, but at a slower rate in orthostatic intolerant women (e.g. time to 50% of total blood pooling, orthostatic intolerant 44 ± 7 s and orthostatic tolerant 26 ± 2 s; P intolerant women (P = 0

  4. Clinical blood pool MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Leiner, Tim [Maastrich University Medical Center (Netherlands). Dept. of Radiology; Goyen, Martin [University Medical Center Hamburg-Eppendorf (Germany); Rohrer, Mathias [Bayer Schering Pharma AG, Berlin (Germany). European Business Unit Diagnostic Imaging; Schoenberg, Stefan O. (eds.) [University Hospital Mannheim Medical Faculty Mannheim - Heidelberg Univ. (Germany). Dept. of Clinical Radiology and Nuclear Medicine

    2008-07-01

    Clinical Blood Pool MR Imaging - This excellent treatise on Vasovist {sup registered} created by a team of exceptional faculty who are pioneers in MR Angiography covers the basic techniques, safety, efficacy, image processing and pharmaco-economic details to successfully implement a new level of MRA image quality with this new contrast agent. Martin Prince, Cornell University, New York The editors and authors have made groundbreaking contributions towards establishing MR angiography in various investigative settings, rendering it more precise and applying it for diverse indications. The work presented here is founded upon the extensive experience of the editors, as well as the broad range of experience from other scientific working groups. Maximilian Reiser, Ludwig Maximilian University, Munich Vasovist {sup registered} (Gadofosveset), worldwide the first blood pool agent, has only recently become available for clinical use, but has already gained wide acceptance as a tool to improve magnetic resonance angiography. This book presents the first in-depth introduction to the basic physicochemical aspects of the agent, the application of Vasovist {sup registered} in clinical MRA, as well as potential clinical applications beyond MRA and patient management-related aspects. The first part of the book explains basic and technical properties of the agent and the differences of Vasovist {sup registered} compared to currently available extracellular agents. The second part contains detailed chapters on safety and efficacy. In the third part the focus is on MR angiographic applications, and in the fourth part of the book potential clinical fields beyond MRA are explored. All clinical chapters feature ready-to-use clinical protocols and a series of take home messages that concisely summarize the current role of blood pool imaging for each specific indication. (orig.)

  5. 99mTc-HMPAO Regional Cerebral Blood Flow SPECT in Transient Ischemic Attacks

    International Nuclear Information System (INIS)

    Ahn, Myeong Im; Park, Young Ha; Lee, Sung Yong; Chung, Soo Kyo; Kim, Jong Woo; Bahk, Yong Whee

    1989-01-01

    Transient ischemic attacks (TJAs) is a syndrome resulting from brain ischemia lasting less than 24 hours. The mechanisms of TIAs may be similar to those of cerebral embolism and thrombosis, and thus TIAs may be followed by cerebral infarction. Despite the availability of CT scanning, the diagnosis and management of TIAs continue to be difficult. Recently SPECT has been advocated as a diagnostic imaging modality. We performed 99m Tc-HMPAO regional cerebral blood flow (rCRF) SPECT in 24 patients with the clinical diagnosis of TIAs to assess its ability to detect early changes of rCBF, and determine the diagnostic value. Ten men and fourteen women with an average of 51 years (range; 27-74 years) were included. All but 8 patients had normal brain CT prior to SPECT. The two patients had moderate degree of brain atrophy and the 6 patients nonspecific calcifications. Eighteen of the 24 patients had abnormal 99m Tc-HMPAO rCBF SPECT. Fifteen had unilateral involvement and the other three had bilateral involvements. Seventy-five percents of the defects were found in the left cerebral hemisphere. According to the distribution of the lesions (total number: 34 lesions), fourteen were in the parietal, eight in the temporal, and the remainders were elsewhere. 99m Tc-HMPAO rCHF SPECT is sensitive in detecting rCRF abnormalities in patients with TIAs, and represent the most accurate diagnostic tool available in the diagnosis of TIAs

  6. Dried blood spots of pooled samples for RHD gene screening in blood donors of mixed ancestry.

    Science.gov (United States)

    Silva-Malta, M C F; Araujo, N C Fidélis; Vieira, O V Neves; Schmidt, L Cayres; Gonçalves, P de Cassia; Martins, M Lobato

    2015-10-01

    In this study, we present a strategy for RHD gene screening based on real-time polymerase chain reaction (PCR) using dried blood spots of pooled samples. Molecular analysis of blood donors may be used to detect RHD variants among the presumed D-negative individuals. RHD genotyping using pooled samples is a strategy to test a large number of samples at a more reasonable cost. RHD gene detection based on real-time PCR using dried blood spots of pooled samples was standardised and used to evaluate 1550 Brazilian blood donors phenotyped as RhD-negative. Positive results were re-evaluated by retesting single samples using real-time PCR and conventional multiplex PCR to amplify five RHD-specific exons. PCR-sequence-specific primers was used to amplify RHDψ allele. We devised a strategy for RHD gene screening using dried blood spots of five pooled samples. Among 1550 serologically D-negative blood donors, 58 (3.74%) had the RHD gene. The non-functional RHDψ allele was detected in 47 samples (3.02%). The present method is a promising strategy to detect the RHD gene among presumed RhD-negative blood donors, particularly for populations with African ancestry. © 2015 British Blood Transfusion Society.

  7. Reduced hypothalamic blood flow after radiation treatment of nasopharyngeal cancer: SPECT studies in 34 patients

    International Nuclear Information System (INIS)

    Chieng, P.U.; Huang, T.S.; Chang, C.C.; Chong, P.N.; Tien, R.D.; Su, C.T.

    1991-01-01

    To determine the effect of cranial irradiation on hypothalamic blood flow, the authors performed 44 regional cerebral blood flow studies with 99mTc hexamethyl propyleneamine oxime (HMPAO) single-photon emission CT (SPECT) on four normal volunteers and 34 patients with pathologically proved nasopharyngeal cancer. Twenty-three men and 15 women, 30-65 years old, were divided into four study groups: group 1 served as a control and consisted of four normal volunteers and six patients studied prior to cranial irradiation; group 2 patients had cranial irradiation half a year before the SPECT study (n = 12, one from group 1); group 3 patients were irradiated 1 year before the study (n = 13, three from group 1 and two from group 2); and group 4 patients were irradiated at least 5 years before SPECT imaging (n = 9). Six patients were studied twice. Quantification of the 99mTc-HMPAO brain SPECT studies was done separately by three radiologists to obtain the hypothalamus/occipital (H/O) and hypothalamus/parasagittal (H/P) ratios. Endocrinologic studies were performed in all cases and the hypothalamus-thyrotroph-thyroid, hypothalamus-gonadotroph-testis (ovary), hypothalamus-lactotroph, hypothalamus-somatotroph, and hypothalamus-corticotroph-adrenal axes were evaluated separately. They determined that regional hypothalamic blood flow was reduced after cranial irradiation in patients with nasopharyngeal cancer. The H/O ratio of groups 3 and 4 did not differ from that of group 2 (one-half year after cranial irradiation). The H/O ratio was significantly reduced 6 months and 1 year after cranial irradiation; mean ± SD = 0.5801 ± 0.0829 (p less than .025), 0.5725 ± 0.0791 (p less than .01) versus 0.6477 ± 0.0458 before cranial irradiation, respectively

  8. Tc-99m ECD brain SPECT in MELAS syndrome: comparison with MR finding

    International Nuclear Information System (INIS)

    Park, Sang Joon; Ryu, Young Hoon; Yoon, Pyeong Ho; Jeon, Tae Joo; Kim, Jai Keun; Nam, Ji Eun; Lee, Jong Doo; Lee, Byung Hee; Shin, Hyung Cheol

    1998-01-01

    The purpose of this study was to evaluate SPECT findings of MELAS syndrome and mitochondrial myopathy and correlate them with MR findings in search of specific imaging features and to assess the role of SPECT in MELAS syndrome. Five patients (four females and one male; age range, 1 to 25 years) who presented with repeated stroke-like episodes or seizures or developmental delay or were asymptomatic but had elevated lactic acid in CSF and serum were evaluated with conventional noncontrast MR imaging and SPECT. MRI demonstrated increased T2 signal intensities in the affected areas of gray and white matters mainly on the parietal (4/5) and occipital lobes (4/5) and in the basal ganglias (1/5), which were not restricted to a specific vascular territory. SPECT demonstrated decreased uptake of Tc-99m ECD on parietal (5/5) and occipital (4/5) and temporal (2/5) and frontal (1/5) lobe and basal ganglia (2/5) and thalami (2/5). In a patient with mitochondrial myopathy who had normal MRI, decreased perfusion is noted on left parietal area and bilateral thalami. Comparison of the numbers of abnormal findings revealed that decreased perfusion seen on SPECT were more numerous than anatomical abnormalities seen on MRI. SPECT may be a sensitive method for pathophysiological study of metabolic disturbances in MELAS. Moreover, in patients with mitochondrial myopathy without clinical encephalopathy, SPECT may play a role in evaluating subclinical encephalopathy even with normal conventional MR findings

  9. Memory-provoked rCBF-SPECT as a diagnostic tool in Alzheimer's disease?

    International Nuclear Information System (INIS)

    Sundstroem, Torbjoern; Riklund, Katrine Aa.; Elgh, Eva; Naesman, Birgitta; Larsson, Anne; Nyberg, Lars

    2006-01-01

    Alzheimer's disease (AD) is a primary degenerative disease that progressively affects all brain functions, with devastating consequences for the patient, the patient's family and society. Rest regional cerebral blood flow (rCBF) could have a strategic role in differentiating between AD patients and normal controls, but its use for this purpose has a low discriminatory capacity. The purpose of this study was to evaluate whether the diagnostic sensitivity of rCBF single-photon emission computed tomography (SPECT) could be increased by using an episodic memory task provocation, i.e. memory-provoked rCBF-SPECT (MP-SPECT). Eighteen persons (73.2±4.8 years) with mild AD and 18 healthy elderly (69.4±3.9 years) were included in the study. The subjects were injected with 99m Tc-hexamethylpropylene amine oxime (HMPAO) during memory provocation with faces and names, followed by an rCBF-SPECT study. The rCBF 99m Tc-HMPAO SPECT images were analysed using statistical parametric mapping (SPM2). Peaks with a false discovery rate corrected value of 0.05 were considered significant. On MP-SPECT, the AD group showed a significant rCBF reduction in the left parietal cortex in comparison with healthy elderly. At rest, no significant group differences were seen. Memory provocation increased the sensitivity of rCBF-SPECT for the detection of AD-related blood flow changes in the brain at the group level. Further studies are needed to evaluate MP-SPECT as a diagnostic tool at the individual level. If a higher sensitivity for AD at the individual level is verified in future studies, a single MP-SPECT study might be sufficient in the clinical setting. (orig.)

  10. Comparison of TITAN hybrid deterministic transport code and MCNP5 for simulation of SPECT

    International Nuclear Information System (INIS)

    Royston, K.; Haghighat, A.; Yi, C.

    2010-01-01

    Traditionally, Single Photon Emission Computed Tomography (SPECT) simulations use Monte Carlo methods. The hybrid deterministic transport code TITAN has recently been applied to the simulation of a SPECT myocardial perfusion study. The TITAN SPECT simulation uses the discrete ordinates formulation in the phantom region and a simplified ray-tracing formulation outside of the phantom. A SPECT model has been created in the Monte Carlo Neutral particle (MCNP)5 Monte Carlo code for comparison. In MCNP5 the collimator is directly modeled, but TITAN instead simulates the effect of collimator blur using a circular ordinate splitting technique. Projection images created using the TITAN code are compared to results using MCNP5 for three collimator acceptance angles. Normalized projection images for 2.97 deg, 1.42 deg and 0.98 deg collimator acceptance angles had maximum relative differences of 21.3%, 11.9% and 8.3%, respectively. Visually the images are in good agreement. Profiles through the projection images were plotted to find that the TITAN results followed the shape of the MCNP5 results with some differences in magnitude. A timing comparison on 16 processors found that the TITAN code completed the calculation 382 to 2787 times faster than MCNP5. Both codes exhibit good parallel performance. (author)

  11. Comparison SPECT-CT with PET-CT in several applications of small-animal models

    International Nuclear Information System (INIS)

    Pan Yifan; Song Shaoli; Huang Gang

    2009-01-01

    With the development of medical science, monitoring dynamic biologic processes in small-animal models of diseases has become one of the most important approaches in medical studies. Important physiologic parameters that traditionally have been characterized by nuclear medicine imaging include blood flow, biochemical metabolism, and cellular receptors. Recently, nuclear medicine has been greatly facilitated by the newer development of dual-modality integrated imaging systems (SPECT-CT and PET-CT), which provide functional and anatomical images in the same scanning session, with the acquired images co-registered by means of the hardware. The purpose of this review is to compare SPECT-CT with PET-CT in several applications of small-animal models. Conclusicn: PET-CT for small animal modes in nledical research in the applications has great advantages, but SPECT-CT is still a very important role, and research low cost. (authors)

  12. Regional cerebral blood flow in various pediatric neurological patients using 123I-IMP SPECT

    International Nuclear Information System (INIS)

    Konishi, Tohru; Naganuma, Yoshihiro; Hongou, Kazuhisa; Murakami, Miyako; Yamatani, Miwa; Okada, Toshio

    1988-01-01

    The recent development of a new radiopharmaceutical 123 I-isopropyl-iodoamphetamine (IMP), which is taken up by the brain from the blood flow, has offered a possibility of constructing scintigraphy maps of regional cerebral blood flow (rCBF) using single photon emission CT. We used this mehtod in various pediatric neurological diseases. Six patients with cerebro-vascular disorders (moya-moya disease 2, infarction 3 and HHE syndrome 1), 6 patients with infectious diseases of CNS (acute encephalitis 4, septic meningitis 1 and SSPE 1) and a miscellaneous group of six patients were studied. The rCBF abnormalities in cerebro-vascular diseases were more extensive and frequent than x-ray CT abnormalities. Repeated studies of IMP-SPECT revealed usefulness for the understanding of changeable hemodynamic pathophysiology and for the judgment of theraptic effectiveness and prognosis. The rCBF decrease in infectious diseases tended to be more diffuse and slight than that in cerebro-vascular diseases. In almost all patients, the area of rCBF decrease coincided with the area of EEG slowing evaluated by EEG topographic analysis. Brain imaging using 123 I-IMP SPECT may reveal functional abnormalities as well as organic lesions. 123 I-IMP SPECT has introduced a new era for the useful application of nuclear medicine to the investigation of pediatric neurological diseases. (author)

  13. Nanoparticle encapsulation in red blood cells enables blood-pool magnetic particle imaging hours after injection

    International Nuclear Information System (INIS)

    Rahmer, J; Gleich, B; Borgert, J; Antonelli, A; Sfara, C; Magnani, M; Tiemann, B; Weizenecker, J

    2013-01-01

    Magnetic particle imaging (MPI) is a new medical imaging approach that is based on the nonlinear magnetization response of super-paramagnetic iron oxide nanoparticles (SPIOs) injected into the blood stream. To date, real-time MPI of the bolus passage of an approved MRI SPIO contrast agent injected into the tail vein of living mice has been demonstrated. However, nanoparticles are rapidly removed from the blood stream by the mononuclear phagocyte system. Therefore, imaging applications for long-term monitoring require the repeated administration of bolus injections, which complicates quantitative comparisons due to the temporal variations in concentration. Encapsulation of SPIOs into red blood cells (RBCs) has been suggested to increase the blood circulation time of nanoparticles. This work presents first evidence that SPIO-loaded RBCs can be imaged in the blood pool of mice several hours after injection using MPI. This finding is supported by magnetic particle spectroscopy performed to quantify the iron concentration in blood samples extracted from the mice 3 and 24 h after injection of SPIO-loaded RBCs. Based on these results, new MPI applications can be envisioned, such as permanent 3D real-time visualization of the vessel tree during interventional procedures, bleeding monitoring after stroke, or long-term monitoring and treatment control of cardiovascular diseases. (paper)

  14. The current status of SPECT or SPECT/CT in South Korea

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Ik Dong; Choi, Eun Kyung; Chung, Yong An [Dept. of Radiology, Incheon Saint Mary' s HospitalThe Catholic University of Korea, Incheon (Korea, Republic of)

    2017-06-15

    The first step to nuclear medicine in Korea started with introduction of the gamma camera in 1969. Although planar images with the gamma camera give important functional information, they have the limitations that result from 2-dimensional images. Single-photon emission computed tomography (SPECT) due to its 3-dimensional image acquisition is superior to earlier planar gamma imaging in image resolution and diagnostic accuracy. As demand for a hybrid functional and anatomical imaging device has increased, integrated SPECT/CT systems have been used. In Korea, SPECT/CT was for the first time installed in 2003. SPECT/CT can eliminate many possible pitfalls on SPECT-alone images, making better attenuation correction and thereby improving image quality. Therefore, SPECT/CT is clinically preferred in many hospitals in various aspects. More recently, additional SPECT/CT images taken from the region with equivocal uptake on planar images have been helpful in making precise interpretation as part of their clinical workup in postoperative thyroid cancer patients. SPECT and SPECT/CT have various advantages, but its clinical application has gradually decreased in recent few years. While some researchers investigated the myocardial blood flow with cardiac PET using F-18 FDG or N-13 ammonia, myocardial perfusion SPECT is, at present, the radionuclide imaging study of choice for the risk stratification and guiding therapy in the coronary artery disease patients in Korea. New diagnostic radiopharmaceuticals for AD have received increasing attention; nevertheless, brain SPECT will remain the most reliable modality evaluating cerebral perfusion.

  15. Clinical comparison of 99mTc exametazime and 123I Ioflupane SPECT in patients with chronic mild traumatic brain injury.

    Science.gov (United States)

    Newberg, Andrew B; Serruya, Mijail; Gepty, Andrew; Intenzo, Charles; Lewis, Todd; Amen, Daniel; Russell, David S; Wintering, Nancy

    2014-01-01

    This study evaluated the clinical interpretations of single photon emission computed tomography (SPECT) using a cerebral blood flow and a dopamine transporter tracer in patients with chronic mild traumatic brain injury (TBI). The goal was to determine how these two different scan might be used and compared to each other in this patient population. Twenty-five patients with persistent symptoms after a mild TBI underwent SPECT with both (99m)Tc exametazime to measure cerebral blood flow (CBF) and (123)I ioflupane to measure dopamine transporter (DAT) binding. The scans were interpreted by two expert readers blinded to any case information and were assessed for abnormal findings in comparison to 10 controls for each type of scan. Qualitative CBF scores for each cortical and subcortical region along with DAT binding scores for the striatum were compared to each other across subjects and to controls. In addition, symptoms were compared to brain scan findings. TBI patients had an average of 6 brain regions with abnormal perfusion compared to controls who had an average of 2 abnormal regions (pTBI symptoms. Both types of scans might have distinct uses in the evaluation of chronic TBI patients depending on the clinical scenario.

  16. Registration of SPECT, PET and/or X-ray CT images in patients with lung cancer

    International Nuclear Information System (INIS)

    Uemura, K.; Toyama, H.; Miyamoto, T.; Yoshikawa, K.; Mori, Y.

    2002-01-01

    Aim: In order to evaluate the therapeutic gain of heavy ion therapy performed on patients with lung cancer, the regional pulmonary functions and the amount of radio tracer accumulation to the tumor, we are investigated by using the region of interest based on anatomical information obtained from X-ray CT. There are many registration techniques for brain images, but not so much for the other organ images that we have studied registration of chest SPECT, PET and/or X-ray CT images. Materials and Methods: Perfusion, ventilation and blood pool images with Tc 99m labeled radiopharmaceuticals and SPECT, tumor images with 11 C-methionine and PET and X-ray CT scans were performed on several patients with lung cancer before and after heavy ion therapy. The registrations of SPECT-CT, PET-CT and CT-CT were performed by using AMIR (Automatic Multimodality Image Registration), which was developed by Babak et al. for registration of brain images. In a case of SPECT-CT registration, each of the three functional images was registered to the X-ray CT image, and the accuracy of each registration was compared. In the studies of PET-CT registration, the transmission images and X-ray CT images were registered at first, because the 11 C-methionine PET images bear little resemblance to the underlying anatomical images. Next, the emission images were realigned by using the same registration parameters. The X-ray CT images obtained from a single subject at the different time were registered to the first X-ray CT images, respectively. Results: In the SPECT-CT registration, the blood pool-CT registration is the best among three SPECT images in visual inspection by radiologists. In the PET-CT registration, the Transmission-CT registrations got good results. Therefore, Emission-CT registrations also got good results. In the CT-CT registration, the X-ray CT images obtained from a single subject at the different time were superimposed well each other except for lower lobe. As the results, it was

  17. Effect of bypass on the motor activation SPECT compared to the acetazolamide SPECT

    International Nuclear Information System (INIS)

    Kawaguchi, Shoichiro; Iwahashi, Hideaki; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime

    2002-01-01

    The authors evaluated and analyzed motor activation single photon emission computed tomography (M-SPECT) in ischemic cerebrovascular disease compared to resting and acetazolamide (ACZ) activated SPECT studies. Seventeen cases with STA-MCA bypass performed for ischemic cerebrovascular disease were examined. The SPECT studies consisting of resting, ACZ activation, and motor activation stages were performed before bypass, at 1 month, and 3 months after bypass. The result of the M-SPECT was expressed as negative or positive. Before bypass: In all 17 cases, SPECT studies of the affected side showed reduction of resting cerebral blood flow (CBF) and reduction of cerebrovascular reserve capacity (CVRC). Eight cases were positive in the M-SPECT study. One week after bypass: The resting CBF increased in seven cases. Four showed preoperative positive M-SPECT. Eight cases showed improvement of the CVRC. Twelve cases were positive in M-SPECT, and two were negative in the preoperative M-SPECT. Three months after bypass: Thirteen cases showed improvement in the resting CBF, and fourteen cases showed improvement of the CVRC. Fourteen cases were positive in the M-SPECT, and among these, 6 were negative in the preoperative M-SPECT. There was a discrepancy between the improvement in CVRC and M-SPECT. M-SPECT study can provide information about the degree of hemodynamic compromise and effect of bypass surgery. (author)

  18. Effect of bypass on the motor activation SPECT compared to the acetazolamide SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, Shoichiro; Iwahashi, Hideaki; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime [Nara Medical Univ., Kashihara (Japan)

    2002-03-01

    The authors evaluated and analyzed motor activation single photon emission computed tomography (M-SPECT) in ischemic cerebrovascular disease compared to resting and acetazolamide (ACZ) activated SPECT studies. Seventeen cases with STA-MCA bypass performed for ischemic cerebrovascular disease were examined. The SPECT studies consisting of resting, ACZ activation, and motor activation stages were performed before bypass, at 1 month, and 3 months after bypass. The result of the M-SPECT was expressed as negative or positive. Before bypass: In all 17 cases, SPECT studies of the affected side showed reduction of resting cerebral blood flow (CBF) and reduction of cerebrovascular reserve capacity (CVRC). Eight cases were positive in the M-SPECT study. One week after bypass: The resting CBF increased in seven cases. Four showed preoperative positive M-SPECT. Eight cases showed improvement of the CVRC. Twelve cases were positive in M-SPECT, and two were negative in the preoperative M-SPECT. Three months after bypass: Thirteen cases showed improvement in the resting CBF, and fourteen cases showed improvement of the CVRC. Fourteen cases were positive in the M-SPECT, and among these, 6 were negative in the preoperative M-SPECT. There was a discrepancy between the improvement in CVRC and M-SPECT. M-SPECT study can provide information about the degree of hemodynamic compromise and effect of bypass surgery. (author)

  19. Post traumatic brain perfusion SPECT analysis using reconstructed ROI maps of radioactive microsphere derived cerebral blood flow and statistical parametric mapping.

    Science.gov (United States)

    McGoron, Anthony J; Capille, Michael; Georgiou, Michael F; Sanchez, Pablo; Solano, Juan; Gonzalez-Brito, Manuel; Kuluz, John W

    2008-02-29

    Assessment of cerebral blood flow (CBF) by SPECT could be important in the management of patients with severe traumatic brain injury (TBI) because changes in regional CBF can affect outcome by promoting edema formation and intracranial pressure elevation (with cerebral hyperemia), or by causing secondary ischemic injury including post-traumatic stroke. The purpose of this study was to establish an improved method for evaluating regional CBF changes after TBI in piglets. The focal effects of moderate traumatic brain injury (TBI) on cerebral blood flow (CBF) by SPECT cerebral blood perfusion (CBP) imaging in an animal model were investigated by parallelized statistical techniques. Regional CBF was measured by radioactive microspheres and by SPECT 2 hours after injury in sham-operated piglets versus those receiving severe TBI by fluid-percussion injury to the left parietal lobe. Qualitative SPECT CBP accuracy was assessed against reference radioactive microsphere regional CBF measurements by map reconstruction, registration and smoothing. Cerebral hypoperfusion in the test group was identified at the voxel level using statistical parametric mapping (SPM). A significant area of hypoperfusion (P TBI. Statistical mapping of the reference microsphere CBF data confirms a focal decrease found with SPECT and SPM. The suitability of SPM for application to the experimental model and ability to provide insight into CBF changes in response to traumatic injury was validated by the SPECT SPM result of a decrease in CBP at the left parietal region injury area of the test group. Further study and correlation of this characteristic lesion with long-term outcomes and auxiliary diagnostic modalities is critical to developing more effective critical care treatment guidelines and automated medical imaging processing techniques.

  20. 99mTc-HMPAO SPECT in brain death

    International Nuclear Information System (INIS)

    Tsuchida, Tatsuro; Sadato, Norihiro; Nishizawa, Sadahiko

    1993-01-01

    Brain single photon emission computed tomography (SPECT) with 99m Tc-d,l-hexamethyl-propyleneamine oxime (HMPAO) was performed twice in a 78-year-old man clinically diagnosed as brain death according to the standard criteria of the Japanese Ministry of Welfare. The first brain SPECT demonstrated the tracer accumulation in the brain, indicating preserved cerebral blood flow. The second brain SPECT performed 3 days later revealed cessation of the blood flow. In patients with preserved cerebral blood flow, the diagnosis of brain death cannot be made, even if they meet the existing criteria, because previous report noted the recovery in some of those patients. Brain perfusion SPECT plays an important role as a confirmatory test for the diagnosis of brain death. (author)

  1. Clinical assessment of hepatic functional reserve using 99mTc DTPA galactosyl human serum albumin SPECT to prognosticate chronic hepatic diseases. Validation of the use of SPECT and a new indicator

    International Nuclear Information System (INIS)

    Onodera, Yuya; Tamaki, Nagara; Miyasaka, Kazuo; Takahashi, Kazuei; Sugai, Yukio; Togashi, Tadashi

    2003-01-01

    cirrhosis group. The cumulative survival rates were lower in Group B than in Group A. The SPECT method was superior to the planar method for assessing LURs. LUR was a suitable indicator of 99m Tc-GSA clearance from the blood pool and of binding to the asialo-glycoprotein receptor. LUR is a simple and clinically useful indicator for the assessment of hepatic functional reserve in chronic hepatic diseases. (author)

  2. A study of acetazolamide-induced changes in cerebral blood flow using {sup 99m}Tc HMPAO SPECT in patients with cerebrovascular disease

    Energy Technology Data Exchange (ETDEWEB)

    Asenbaum, S. [Neurological Clinic, Univ. Vienna (Austria); Reinprecht, A. [Neurosurgical Clinic, Univ. Vienna (Austria); Bruecke, T. [Neurological Clinic, Univ. Vienna (Austria); Wenger, S. [Neurological Clinic, Univ. Vienna (Austria); Podreka, I. [Neurological Clinic, Univ. Vienna (Austria); Deecke, L. [Neurological Clinic, Univ. Vienna (Austria)

    1995-01-01

    For semiquantification of SPECT studies we tried to calculate cerebral {sup 99m}Tc-HMPAO uptake related to injected dose and estimated brain volume. The method was applied to SPECT investigations of 27 patients who had a least one ischaemic attack and a confirmed 80-100% stenosis of the corresponding internal carotid artery (ICA). Vascular reactivity was tested by parenteral administration of acetazolamide (AZ). Increase in HMPAO uptake after AZ was evident in both hemispheres, although the increase (AZ effect) was significantly lower in the affected hemisphere (+24% versus +28%). No interhemispheric uptake differences were seen in patients with largely normal SPECT studies, although local asymmetries in HMPAO deposition were visible. Patients with low density lesions on CT and with a well-demarcated lesion in the same location on SPECT revealed interhemispheric uptake differences, with lower uptake on the affected side. This was not due solely to alterations in the lesion, but also to reduced HMPAO uptake and AZ effect in the surrounding area. The AZ effect showed no correlation with angiographic findings, indicating no major haemodynamic influence of the ICA stenosis on cerebral hemisphere perfusion. Calculated cerebral HMPAO uptake changes after AZ administration were in good accordance with absolute cerebral blood flow measurements, and made interindividual comparisons possible. However, as changes in the area around an infarct or local reduction in vascular reserve may not be reproduced adequately by uptake calculations, visual inspection is still necessary. (orig.)

  3. Diagnosis of hemodynamic compromise in patients with chronic cerebral ischemia; Measurement of cerebral blood volume (CBV) with sup 99m Tc-RBC SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, Satoshi; Sakuragi, Mitsugi; Motomiya, Mineo; Nakagawa, Tango; Mitsumori, Kenji; Tsuru, Mitsuo (Hokkaido Neurosurgical Memorial Hospital (Japan)); Takigawa, Shugo; Kamiyama, Hiroyasu; Abe, Hiroshi

    1990-03-01

    To evaluate the efficacy of tests for selecting patients with hemodynamic compromise, measurement of cerebral blood volume (CBV) with {sup 99m}Tc-RBC single photon emission computed tomography (SPECT) was performed in thirteen patients with occlusive cerebrovascular disease, and was compared with results obtained by {sup 133}Xe SPECT and acetazolamide (Diamox) test. All patients in our study suffered TIA, RIND, or minor completed stroke. Cerebral angiography demonstrated severe stenosis or occlusion in the ipsilateral internal carotid artery or middle cerebral artery, although plain CT scan or MRI revealed no or, if any, only localized infarcted lesions. Regional cerebral blood volume (rCBV) was measured with {sup 99m}Tc-RBC SPECT and regional cerebral blood flow (rCBF) was measured with {sup 133}Xe SPECT before and after intravenous injection of 10 - 12 mg/kg acetazolamide (Diamox). Our results suggest that the ipsilateral rCBV/rCBF (mean transit time) is a more sensitive index of the cerebral perfusion reserve than the use of only rCBV or rCBF of the ipsilateral hemisphere. Also, the ipsilateral rCBV/rCBF is significantly correlated (r= -0.72) with the Diamox reactivity of rCBF, which is considered to represent the cerebral vasodilatory capacity in patients with chronic cerebral ischemia. Postoperative SPECT study revealed remarkable improvement of ipsilateral rCBV/rCBF and Diamox reactivity in four patients who underwent EC/IC bypass surgery to improve the hemodynamic compromise. In conclusion, our results suggest that the measurement of rCBV/rCBF with {sup 133}Xe SPECT and {sup 99m}Tc-RBC SPECT is useful for detecting the hemodynamic compromise in patients with occlusive cerebrovascular disease. (author).

  4. {sup 67}Ga-SPECT/CT with a hybrid system in the clinical management of lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Palumbo, Barbara; Sivolella, Silvio; Palumbo, Renato [University of Perugia, Nuclear Medicine Section, Department of Radiological Sciences, Perugia (Italy); Palumbo, Isabella; Liberati, Anna Marina [University of Perugia, Internal Medicine and Oncology, Department of Clinical and Experimental Medicine, Perugia (Italy)

    2005-09-01

    The purpose of this study was to investigate the added value of co-registered fusion imaging using a hybrid system in patients with lymphoma. Twenty-four lymphoma patients underwent {sup 67}Ga-SPECT/CT using a hybrid tomograph consisting of a dual-head, variable-angle gamma camera and a low-dose X-ray tube. Results were compared with those of SPECT alone. Forty-five lesions were identified by SPECT alone, while 49 were detected by SPECT/CT. Forty out of the 45 lesions observed on SPECT were confirmed as lymphoma, but five were due to other causes (thoracic aorta blood pool activity, sialoadenitis in the submandibular gland, bowel activity, rib fracture and bone marrow activation due to radiotherapy). SPECT/CT identified nine more neoplastic lesions compared with SPECT alone: four areas of radiopharmaceutical accumulation were observed in para-aortic lymph nodes, three in the spleen, one in the liver and one in para-iliac lymph nodes. In five cases, SPECT/CT provided additional anatomical information over SPECT alone. In four patients, four large areas of {sup 67}Ga uptake (one mediastinal, two supraclavicular and one para-aortic) were better characterised; in one subject uptake was localised in the seventh thoracic vertebra only by SPECT/CT. Hybrid imaging provided additional data in 13 patients (54.2%), thus inducing oncologists to reconsider the therapeutic approach in eight subjects (33.2%): unnecessary treatment was avoided in four (16.6%) while therapy was altered in another four (16.6%). SPECT/CT hybrid system is able to provide information not obtained by SPECT alone. It allows the anatomical localisation of lymphoma and physiological radiopharmaceutical uptake, facilitates the diagnosis of tumours located in the abdomen (subdiaphragmatic lesions) and provides information that may cause a change in therapeutic strategy. (orig.)

  5. Comparison of V/Q SPECT and planar V/Q lung scintigraphy in diagnosing acute pulmonary embolism

    DEFF Research Database (Denmark)

    Borgwardt, Henrik Gutte; Mortensen, Jann; Jensen, Claus Verner

    2010-01-01

    Planar ventilation/perfusion (V/Q) scintigraphy is currently the standard method for the diagnosis of pulmonary embolism (PE) in most nuclear medicine centers. However, recent studies have shown a superior sensitivity and specificity when applying V/Q single photon emission computed tomography...... (SPECT) in diagnosing PE. This study evaluated the diagnostic performance of three-dimensional V/Q SPECT in comparison with planar V/Q scintigraphy....

  6. Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema?

    Science.gov (United States)

    Froeling, Vera; Heimann, Uwe; Huebner, Ralf-Harto; Kroencke, Thomas J; Maurer, Martin H; Doellinger, Felix; Geisel, Dominik; Hamm, Bernd; Brenner, Winfried; Schreiter, Nils F

    2015-07-01

    To evaluate the utility of attenuation correction (AC) of V/P SPECT images for patients with pulmonary emphysema. Twenty-one patients (mean age 67.6 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. AC/non-AC V/P SPECT images were compared visually and semiquantitatively. Visual comparison of AC/non-AC images was based on a 5-point likert scale. Semiquantitative comparison assessed absolute counts per lung (aCpLu) and lung lobe (aCpLo) for AC/non-AC images using software-based analysis; percentage counts (PC = (aCpLo/aCpLu) × 100) were calculated. Correlation between AC/non-AC V/P SPECT images was analyzed using Spearman's rho correlation coefficient; differences were tested for significance with the Wilcoxon rank sum test. Visual analysis revealed high conformity for AC and non-AC V/P SPECT images. Semiquantitative analysis of PC in AC/non-AC images had an excellent correlation and showed no significant differences in perfusion (ρ = 0.986) or ventilation (ρ = 0.979, p = 0.809) SPECT/CT images. AC of V/P SPECT images for lung lobe-based function imaging in patients with pulmonary emphysema do not improve visual or semiquantitative image analysis.

  7. SPECT in psychiatry

    International Nuclear Information System (INIS)

    Barocka, A.; Feistel, H.; Ebert, D.; Lungershausen, E.

    1993-01-01

    This review presents Single Photon Emission Computed Tomography (SPECT) as a powerful tool for clinical use and research in psychiatry. Its focus is on regional cerebral blood flow, measured with technetium labelled HMPAO. In addition, first results with brain receptor imaging, concerning dopamin-D 2 and benzodiazepine receptors, are covered. Due to major improvements in image quality, and impressive number of results has been accumulated in the past three years. The authors caution against using SPECT results as markers for disease entities. A finding like 'hypofrontality' is considered typical of a variety of mental disorders. Clearly both, more experience with SPECT and contributions from psychopathology, are needed. (orig.) [de

  8. Regional cerebral blood flow in various pediatric neurological patients using /sup 123/I-IMP SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, Tohru; Naganuma, Yoshihiro; Hongou, Kazuhisa; Murakami, Miyako; Yamatani, Miwa; Okada, Toshio

    1988-03-01

    The recent development of a new radiopharmaceutical /sup 123/I-isopropyl-iodoamphetamine (IMP), which is taken up by the brain from the blood flow, has offered a possibility of constructing scintigraphy maps of regional cerebral blood flow (rCBF) using single photon emission CT. We used this mehtod in various pediatric neurological diseases. Six patients with cerebro-vascular disorders (moya-moya disease 2, infarction 3 and HHE syndrome 1), 6 patients with infectious diseases of CNS (acute encephalitis 4, septic meningitis 1 and SSPE 1) and a miscellaneous group of six patients were studied. The rCBF abnormalities in cerebro-vascular diseases were more extensive and frequent than x-ray CT abnormalities. Repeated studies of IMP-SPECT revealed usefulness for the understanding of changeable hemodynamic pathophysiology and for the judgment of theraptic effectiveness and prognosis. The rCBF decrease in infectious diseases tended to be more diffuse and slight than that in cerebro-vascular diseases. In almost all patients, the area of rCBF decrease coincided with the area of EEG slowing evaluated by EEG topographic analysis. Brain imaging using /sup 123/I-IMP SPECT may reveal functional abnormalities as well as organic lesions. /sup 123/I-IMP SPECT has introduced a new era for the useful application of nuclear medicine to the investigation of pediatric neurological diseases.

  9. Post traumatic brain perfusion SPECT analysis using reconstructed ROI maps of radioactive microsphere derived cerebral blood flow and statistical parametric mapping

    International Nuclear Information System (INIS)

    McGoron, Anthony J; Capille, Michael; Georgiou, Michael F; Sanchez, Pablo; Solano, Juan; Gonzalez-Brito, Manuel; Kuluz, John W

    2008-01-01

    Assessment of cerebral blood flow (CBF) by SPECT could be important in the management of patients with severe traumatic brain injury (TBI) because changes in regional CBF can affect outcome by promoting edema formation and intracranial pressure elevation (with cerebral hyperemia), or by causing secondary ischemic injury including post-traumatic stroke. The purpose of this study was to establish an improved method for evaluating regional CBF changes after TBI in piglets. The focal effects of moderate traumatic brain injury (TBI) on cerebral blood flow (CBF) by SPECT cerebral blood perfusion (CBP) imaging in an animal model were investigated by parallelized statistical techniques. Regional CBF was measured by radioactive microspheres and by SPECT 2 hours after injury in sham-operated piglets versus those receiving severe TBI by fluid-percussion injury to the left parietal lobe. Qualitative SPECT CBP accuracy was assessed against reference radioactive microsphere regional CBF measurements by map reconstruction, registration and smoothing. Cerebral hypoperfusion in the test group was identified at the voxel level using statistical parametric mapping (SPM). A significant area of hypoperfusion (P < 0.01) was found as a response to the TBI. Statistical mapping of the reference microsphere CBF data confirms a focal decrease found with SPECT and SPM. The suitability of SPM for application to the experimental model and ability to provide insight into CBF changes in response to traumatic injury was validated by the SPECT SPM result of a decrease in CBP at the left parietal region injury area of the test group. Further study and correlation of this characteristic lesion with long-term outcomes and auxiliary diagnostic modalities is critical to developing more effective critical care treatment guidelines and automated medical imaging processing techniques

  10. Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and99mTc-tetrofosmin: Method and validation

    OpenAIRE

    Shrestha, U; Sciammarella, M; Alhassen, F; Yeghiazarians, Y; Ellin, J; Verdin, E; Boyle, A; Seo, Y; Botvinick, EH; Gullberg, GT

    2017-01-01

    © 2015, American Society of Nuclear Cardiology. Background: The objective of this study was to measure myocardial blood flow (MBF) in humans using 99m Tc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). Methods: Dynamic SPECT using 99m Tc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients w...

  11. Post traumatic brain perfusion SPECT analysis using reconstructed ROI maps of radioactive microsphere derived cerebral blood flow and statistical parametric mapping

    Directory of Open Access Journals (Sweden)

    Gonzalez-Brito Manuel

    2008-02-01

    Full Text Available Abstract Background Assessment of cerebral blood flow (CBF by SPECT could be important in the management of patients with severe traumatic brain injury (TBI because changes in regional CBF can affect outcome by promoting edema formation and intracranial pressure elevation (with cerebral hyperemia, or by causing secondary ischemic injury including post-traumatic stroke. The purpose of this study was to establish an improved method for evaluating regional CBF changes after TBI in piglets. Methods The focal effects of moderate traumatic brain injury (TBI on cerebral blood flow (CBF by SPECT cerebral blood perfusion (CBP imaging in an animal model were investigated by parallelized statistical techniques. Regional CBF was measured by radioactive microspheres and by SPECT 2 hours after injury in sham-operated piglets versus those receiving severe TBI by fluid-percussion injury to the left parietal lobe. Qualitative SPECT CBP accuracy was assessed against reference radioactive microsphere regional CBF measurements by map reconstruction, registration and smoothing. Cerebral hypoperfusion in the test group was identified at the voxel level using statistical parametric mapping (SPM. Results A significant area of hypoperfusion (P Conclusion The suitability of SPM for application to the experimental model and ability to provide insight into CBF changes in response to traumatic injury was validated by the SPECT SPM result of a decrease in CBP at the left parietal region injury area of the test group. Further study and correlation of this characteristic lesion with long-term outcomes and auxiliary diagnostic modalities is critical to developing more effective critical care treatment guidelines and automated medical imaging processing techniques.

  12. Regional cerebral blood flow in elderly patients with heart failure evaluated with SPECT

    International Nuclear Information System (INIS)

    Alves, T.C.T.F.; Fraguas, R.; Busatto, G.; Garrido, G.; Buchpiguel, C.A.; Rays, J.; Wajngarten, M.; Robilotta, C.C.; Meneghetti, J.C.

    2002-01-01

    Introduction: Heart failure (HF) may be related to brain dysfunction due to reduced cerebral blood flow (CBF) and white matter lesions. However, no studies have yet used quantitative regional CBF (rCBF) techniques to demonstrate the presence of significant functional abnormalities in representative samples of cardiac patients compared with normal controls. Aim: The purpose of this study was to investigate the rCBF distribution as assessed with SPECT in a group of elderly patients with HF in comparison with a normal control group. The hypothesis were: (1) HF would be associated with rCBF reductions in comparison to healthy controls. Methodology: We studied a group of 36 HF patients functional class II or III from New York Heart Association (NYHA), divided in 19 depressed (74.6 +/- 6.8 years) and 17 non depressed (73.7 +/- 5.4 years), and compared to 19 normal subjects (71.1 +/- 4.8 years), matched for age, sex, cerebral dominance and social level. Brain perfusion was evaluated with a double-headed SPECT system (Sophy-DST) with high-resolution collimators (128x128 matrix, 128 views, 30s/view) after 30mcI 99mTc-HMPAO injection. Group differences were investigated using SPM99, with a p<0.001 statistical threshold (uncorrected for multiple comparisons). Results: Significant rCBF reductions were seen in the HF non depressed group relative to healthy controls in the right lateral temporal lobe, cuneus and precuneus, as well as in a small area of the medial prefrontal cortex. In the HF depressed group, significant cortical rCBF reductions relative to healthy controls were seen in similar locations but more extensively. In addition, the HF depressed group showed significant rCBF reductions relative to controls limbic and subcortical areas, including the right parahypocampal gyrus, posterior cingulate, thalamus and caudate at the border of the lateral ventricle, and bilaterally in the posterior insula. Conclusion: The presence of greater areas of hypoperfusion in the HF

  13. Direct comparison study between FDG-PET and IMP-SPECT for diagnosing Alzheimer's disease using 3D-SSP analysis in the same patients

    International Nuclear Information System (INIS)

    Nihashi, Takashi; Hayasaka, Kazumasa; Yatsuya, Hiroshi

    2007-01-01

    The purpose of this study was to evaluate and compare the diagnostic ability of 2-[ 18 F]-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) and N-isopropyl-p- 123 I iodoamphetamine single photon emission computed tomography (IMP-SPECT) using three-dimensional stereotactic surface projections (3D-SSP) in patients with moderate Alzheimer's disease (AD). FDG-PET and IMP-SPECT were performed within 3 months in 14 patients with probable moderate AD. Z-score maps of FDG-PET and IMP-SPECT images of a patient were obtained by comparison with data obtained from control subjects. Four expert physicians evaluated and graded the glucose hypometabolism and regional cerebral blood flow (rCBF), focusing in particular on the posterior cingulate gyri/precunei and parietotemporal regions, and determined the reliability for AD. Receiver operating characteristic (ROC) curves were applied to the results for clarification. To evaluate the correlation between two modalities, the regions of interest (ROIs) were set in the posterior cingulate gyri/precunei and parietotemporal region on 3D-SSP images, and mean Z-values were calculated. No significant difference was observed in the area under the ROC curve (AUC) between FDG-PET and IMP-SPECT images (FDG-PET 0.95, IMP-SPECT 0.94). However, a significant difference (P<0.05) was observed in the AUC for the posterior cingulate gyri/precuneus (FDG-PET 0.94, IMP-SPECT 0.81). The sensitivity and specificity of each modality were 86%, and 97% for FDG-PET and 70% and 100% for IMP-SPECT. We could find no significant difference between FDG-PET and IMP-SPECT in terms of diagnosing moderate AD using 3D-SSP. There was a high correlation between the two modalities in the parietotemporal region (Spearman's r=0.82, P<0.001). The correlation in the posterior cingulate gyri/precunei region was lower than that in the parietotemporal region (Spearman's r=0.63, P<0.016). (author)

  14. Detection of misery perfusion in the cerebral hemisphere with chronic unilateral major cerebral artery steno-occlusive disease using crossed cerebellar hypoperfusion: comparison of brain SPECT and PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Yoshiyasu; Ogasawara, Kuniaki; Saito, Hideo; Takahashi, Yoshihiro; Ogasawara, Yasushi; Kobayashi, Masakazu; Ogawa, Akira [Iwate Medical University, Department of Neurosurgery, Morioka (Japan); Iwate Medical University, Cyclotron Research Center, Morioka (Japan); Terasaki, Kazunori [Iwate Medical University, Cyclotron Research Center, Morioka (Japan); Yoshida, Kenji; Beppu, Takaaki; Kubo, Yoshitaka; Fujiwara, Shunrou [Iwate Medical University, Department of Neurosurgery, Morioka (Japan); Tsushima, Eiki [Hirosaki University, Graduate School of Health Sciences, Hirosaki (Japan)

    2013-10-15

    In patients with unilateral internal carotid or middle cerebral artery (ICA or MCA) occlusive disease, the degree of crossed cerebellar hypoperfusion that is evident within a few months after the onset of stroke may reflect cerebral metabolic rate of oxygen in the affected cerebral hemisphere relative to that in the contralateral cerebral hemisphere. The aim of the present study was to determine whether the ratio of blood flow asymmetry in the cerebellar hemisphere to blood flow asymmetry in the cerebral hemisphere on positron emission tomography (PET) and single photon emission computed tomography (SPECT) correlates with oxygen extraction fraction (OEF) asymmetry in the cerebral hemisphere on PET in patients with chronic unilateral ICA or MCA occlusive disease and whether this blood flow ratio on SPECT detects misery perfusion in the affected cerebral hemisphere in such patients. Brain blood flow and OEF were assessed using {sup 15}O-PET and N-isopropyl-p-[{sup 123}I]iodoamphetamine ({sup 123}I-IMP) SPECT, respectively. All images were anatomically standardized using SPM2. A region of interest (ROI) was automatically placed in the bilateral MCA territories and in the bilateral cerebellar hemispheres using a three-dimensional stereotaxic ROI template, and affected-to-contralateral asymmetry in the MCA territory or contralateral-to-affected asymmetry in the cerebellar hemisphere was calculated. Sixty-three patients with reduced blood flow in the affected cerebral hemisphere on {sup 123}I-IMP SPECT were enrolled in this study. A significant correlation was observed between MCA ROI asymmetry of PET OEF and the ratio of cerebellar hemisphere asymmetry of blood flow to MCA ROI asymmetry of blood flow on PET (r = 0.381, p = 0.0019) or SPECT (r = 0.459, p = 0.0001). The correlation coefficient was higher when reanalyzed in a subgroup of 43 patients undergoing a PET study within 3 months after the last ischemic event (r = 0.541, p = 0.0001 for PET; r = 0.609, p < 0

  15. Measurement of mean cerebral blood flow using SPECT and dementia rating scales in the memory clinic

    International Nuclear Information System (INIS)

    Kawahata, Nobuya; Daitoh, Nobuyuki; Shirai, Fumie; Yoshikawa, Ayumi; Gotoh, Chiharu

    1997-01-01

    We investigated the association between mean cerebral blood flow (mCBF) values using single photon emission computed tomography (SPECT) and cognitive performance scores of three dementia rating scales (ADAS, MMSE, HDS-R). Mean CBF was measured by the 123 I-IMP-ARG method in a selected group of 51 out-patients aged 41 to 90 years and by the 99m Tc-ECD method in the other group of 57 out-patients aged 51 to 91 years. Simple regressions were calculated for each of the neuropsychological clusters and mCBF values. In 123 I-IMP-ARG-SPECT study, there was a significant correlation between the mCBF values and HDS-R scores (R=0.37, p=0.01). 99m Tc-ECD-SPECT study revealed statistically significant correlations between the mCBF values and ADAS scores (R=-0.48, p 123 I-IMP-ARG-SPECT study and 99m Tc-ECD-SPECT study showed the progressive declines of mCBF with advancing cognitive dysfunctions. Using the cut-off point study (23/24 scores in MMSE and 20/21 scores in HDS-R), we have found that the patients with cognitive dysfunctions had lower mCBF values than the patients with those in each group of aged 60-69 years, 70-79 years, and 80-89 years. However, the difference of mCBF values between the groups with cognitive dysfunctions and without those had decreased gradually with advancing age. The present study suggests that SPECT can provide important functional informations to assess the cognitive impairment in patients with the memory disturbance. (author)

  16. Motor activation SPECT for the neurosurgical diseases. Clinical application

    International Nuclear Information System (INIS)

    Noguchi, Hiroshi; Kawaguchi, Shoichiro; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime

    1999-01-01

    We evaluated and analyzed the motor activation single photon emission computed tomography (M-SPECT) findings on patients with ischemic cerebrovascular diseases (CVD). The M-SPECT studies were carried out on 91 patients with ischemic cerebrovascular diseases. The M-SPECT study was performed using the finger opposition task in each case. The SPECT images were superimposed on the magnetic resonance images (MRIs) for each case using Image Fusion Software. The result of the M-SPECT was expressed as positive or negative. The cases with a marked increase of blood flow in the sensorio-motor cortex after the finger opposition task were categorized as positive, and those cases showing no marked increase of blood flow were categorized as negative. Among the 91 cases examined, 53 (58%) were categorized as positive in the M-SPECT study. Among the negative M-SPECT cases treated with revascularization surgery, there were some cases showing positive M-SPECT results postoperatively. The cases without any revascularization surgery did not change the M-SPECT findings in each during the follow-up period. The M-SPECT procedure for examining intracranial lesions could provide the cortical localization of the motor function. The M-SPECT procedure in the ischemic CVDs contributes to knowledge about the choices of treatment and the evaluation of the treatment result. (author)

  17. Motor activation SPECT for the neurosurgical diseases. Clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Noguchi, Hiroshi; Kawaguchi, Shoichiro; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime [Nara Medical Univ., Kashihara (Japan)

    1999-08-01

    We evaluated and analyzed the motor activation single photon emission computed tomography (M-SPECT) findings on patients with ischemic cerebrovascular diseases (CVD). The M-SPECT studies were carried out on 91 patients with ischemic cerebrovascular diseases. The M-SPECT study was performed using the finger opposition task in each case. The SPECT images were superimposed on the magnetic resonance images (MRIs) for each case using Image Fusion Software. The result of the M-SPECT was expressed as positive or negative. The cases with a marked increase of blood flow in the sensorio-motor cortex after the finger opposition task were categorized as positive, and those cases showing no marked increase of blood flow were categorized as negative. Among the 91 cases examined, 53 (58%) were categorized as positive in the M-SPECT study. Among the negative M-SPECT cases treated with revascularization surgery, there were some cases showing positive M-SPECT results postoperatively. The cases without any revascularization surgery did not change the M-SPECT findings in each during the follow-up period. The M-SPECT procedure for examining intracranial lesions could provide the cortical localization of the motor function. The M-SPECT procedure in the ischemic CVDs contributes to knowledge about the choices of treatment and the evaluation of the treatment result. (author)

  18. Memory-provoked rCBF-SPECT as a diagnostic tool in Alzheimer's disease?

    Energy Technology Data Exchange (ETDEWEB)

    Sundstroem, Torbjoern; Riklund, Katrine Aa. [Umeaa University, Umeaa University Hospital, Department of Radiation Sciences, Diagnostic Radiology, Umeaa (Sweden); Elgh, Eva; Naesman, Birgitta [Umeaa University, Department of Community Medicine and Rehabilitation, Geriatric Medicine, Umeaa (Sweden); Larsson, Anne [Umeaa University, Department of Radiation Sciences, Radiation Physics, Umeaa (Sweden); Nyberg, Lars [Umeaa University, Department of Psychology, Umeaa (Sweden)

    2006-01-01

    Alzheimer's disease (AD) is a primary degenerative disease that progressively affects all brain functions, with devastating consequences for the patient, the patient's family and society. Rest regional cerebral blood flow (rCBF) could have a strategic role in differentiating between AD patients and normal controls, but its use for this purpose has a low discriminatory capacity. The purpose of this study was to evaluate whether the diagnostic sensitivity of rCBF single-photon emission computed tomography (SPECT) could be increased by using an episodic memory task provocation, i.e. memory-provoked rCBF-SPECT (MP-SPECT). Eighteen persons (73.2{+-}4.8 years) with mild AD and 18 healthy elderly (69.4{+-}3.9 years) were included in the study. The subjects were injected with{sup 99m}Tc-hexamethylpropylene amine oxime (HMPAO) during memory provocation with faces and names, followed by an rCBF-SPECT study. The rCBF{sup 99m}Tc-HMPAO SPECT images were analysed using statistical parametric mapping (SPM2). Peaks with a false discovery rate corrected value of 0.05 were considered significant. On MP-SPECT, the AD group showed a significant rCBF reduction in the left parietal cortex in comparison with healthy elderly. At rest, no significant group differences were seen. Memory provocation increased the sensitivity of rCBF-SPECT for the detection of AD-related blood flow changes in the brain at the group level. Further studies are needed to evaluate MP-SPECT as a diagnostic tool at the individual level. If a higher sensitivity for AD at the individual level is verified in future studies, a single MP-SPECT study might be sufficient in the clinical setting. (orig.)

  19. 99mTc-HMPAO Brain SPECT in Seizure Disorder: Comparison Brain SPECT, MRI / CT and EEG

    International Nuclear Information System (INIS)

    Yang, Hyung In; Im, Ju Hyuk; Choi, Chang Woon; Lee, Dong Soo; Chung, June Key; No, Jae Kyu; Lee, Myung Chul; Koh, Chang Soon

    1994-01-01

    We studied 115 patients with seizure who had been performed brain SPECT brain MRI of CT and EEG. To evaluate the pattern of brain SPECT in seizure patients 28 of them had secondary epilepsies, 87 had primary epilepsies. In primary epilepsies, 42 were generalized seizure and 45 were partial seizure. The causes of secondary epilepsies were congenital malformation, cerebromalacia, cerebral infarction ultiple sclerosis, AV-malformation. granuloma and etc, in order. In 28 secondary epilepsies, 25 of them, brain SPECT lesions was concordant with MRI or CT lesions. 3 were disconcordant. The brain SPECT findings of generalized seizure were normal in 22 patients, diffuse irregular decreased perfusion in 8, decreased in frontal cortex in 4. temporal in 5 and frontotemporal in 3. In 45 partial seizure, 19 brain SPECT were concordant with EEG (42.4%).

  20. Cardiac cine MRI: Comparison of 1.5 T, non-enhanced 3.0 T and blood pool enhanced 3.0 T imaging

    International Nuclear Information System (INIS)

    Gerretsen, S.C.; Versluis, B.; Bekkers, S.C.A.M.; Leiner, T.

    2008-01-01

    Introduction: Cardiac cine imaging using balanced steady state free precession sequences (bSSFP) suffers from artefacts at 3.0 T. We compared bSSFP cardiac cine imaging at 1.5 T with gradient echo imaging at 3.0 T with and without a blood pool contrast agent. Materials and methods: Eleven patients referred for cardiac cine imaging underwent imaging at 1.5 T and 3.0 T. At 3.0 T images were acquired before and after administration of 0.03 mmol/kg gadofosveset. Blood pool signal-to-noise ratio (SNR), temporal variations in SNR, ejection fraction and myocardial mass were compared. Subjective image quality was scored on a four-point scale. Results: Blood pool SNR increased with more than 75% at 3.0 T compared to 1.5 T (p < 0.001); after contrast administration at 3.0 T SNR increased with 139% (p < 0.001). However, variations in blood pool SNR at 3.0 T were nearly three times as high versus those at 1.5 T in the absence of contrast medium (p < 0.001); after contrast administration this was reduced to approximately a factor 1.4 (p = 0.21). Saturation artefacts led to significant overestimation of ejection fraction in the absence of contrast administration (1.5 T: 44.7 ± 3.1 vs. 3.0 T: 50.7 ± 4.2 [p = 0.04] vs. 3.0 T post contrast: 43.4 ± 2.9 [p = 0.55]). Subjective image quality was highest for 1.5 T (2.8 ± 0.3), and lowest for non-enhanced 3.0 T (1.7 ± 0.6; p = 0.006). Conclusions: GRE cardiac cine imaging at 3.0 T after injection of the blood pool agent gadofosveset leads to improved objective and subjective cardiac cine image quality at 3.0 T and to the same conclusions regarding cardiac ejection fraction compared to bSSFP imaging at 1.5 T

  1. Functional and morphological findings in early and advanced stages of HIV infection: A comparison of 99mTc-HMPAO SPECT with CT and MRI studies

    International Nuclear Information System (INIS)

    Tatsch, K.; Bauer, W.M.; Markl, A.; Kirsch, C.M.; Schielke, E.; Einhaeupl, K.M.

    1990-01-01

    In fourty patients at early and advanced stages of HIV infection (Water-Reed stages I-VI) regional cerebral blood flow was determined by 99m Tc-HMPAO SPECT, comparing the results with CT and MRI findings. All patients with HIV encephalopathy (AIDS dementia complex) had pathologic SPECT results (multilocular, patchy uptake defects), but also in earlier and even earliest stages of HIV infection positive SPECT findings were observed. Compared to functional SPECT imaging, morphologically orientated method (CT, MRI) were insensitive in detecting HIV-induced foci: More than 50% of the patients with pathologic SPECT findings had negative CT or MRI scans. Most patients in advanced Walter Reed stages had neurological abnormalities accompanied by positive SPECT. Subtle alterations of HMPAO uptake were observed even in a few cases of early HIV infection without neurological CNS symptoms. The data presented suggest that HMPAO SPECT is highly sensitive in the detection of altered brain perfusion not only in advanced but also early stages of HIV infection. Changes in regional cerebral blood flow are presented before noticeable structural defects may be observed. (orig./MG) [de

  2. Radionuclide cisternography: SPECT and 3D-rendering. Radionuklidzisternographie: SPECT- und 3D-Technik

    Energy Technology Data Exchange (ETDEWEB)

    Henkes, H; Huber, G; Piepgras, U [Universitaet des Saarlandes, Homburg/Saar (Germany, F.R.). Abt. fuer Neuroradiologie; Hierholzer, J [Freie Univ. Berlin (Germany, F.R.). Strahlenklinik und Poliklinik; Cordes, M [British Columbia Univ., Vancouver, BC (Canada). Belzberg Lab. of Neuroscience

    1991-10-01

    Radionuclide cisternography is indicated in the clinical work-up for hydrocephalus, when searching for CSF leaks, and when testing whether or not intracranial cystic lesions are communicating with the adjacent subarachnoid space. This paper demonstrates the feasibility and diagnostic value of SPECT and subsequent 3D surface rendering in addition to conventional rectilinear CSF imaging in eight patients. Planar images allowed the evaluation of CSF circulation and the detection of CSF fistula. They were advantageous in examinations 48 h after application of {sup 111}In-DTPA. SPECT scans, generated 4-24 h after tracer application, were superior in the delineation of basal cisterns, especially in early scans; this was helpful in patients with pooling due to CSF fistula and in cystic lesions near the skull base. A major drawback was the limited image quality of delayed scans, when the SPECT data were degraded by a low count rate. 3D surface rendering was easily feasible from SPECT data and yielded high quality images. The presentation of the spatial distribution of nuclide-contaminated CSF proved especially helpful in the area of the basal cisterns. (orig.).

  3. Serial SPECT in children with partial epilepsy

    International Nuclear Information System (INIS)

    Hosoya, Machiko; Ushiku, Hideo

    1995-01-01

    We performed serial single-photon emission CT (SPECT) with N-isopropyl-p-( 123 I)-Iodoamphetamine to measure the regional cerebral blood flow (rCBF) in 15 children with partial epilepsy. SPECT showed focal changes in 14 cases. Ten cases had abnormalities in the initial SPECT and another four cases in the second test. The cases with normal rCBF in initial SPECT had been tested in an early phase after the onset, and then decreased rCBF were observed in the second SPECT. The cases with both abnormal rCBF in the initial SPECT and improved rCBF in the second SPECT showed good prognosis in clinico-electrophysiological evolutions. In cases with abnormal changes of rCBF in the second SPECT, clinical prognosis was found to be not so good. These findings suggest that serial SPECT may be used to follow the course of epilepsy. (author)

  4. 18F-FDG-labeled red blood cell PET for blood-pool imaging: preclinical evaluation in rats.

    Science.gov (United States)

    Matsusaka, Yohji; Nakahara, Tadaki; Takahashi, Kazuhiro; Iwabuchi, Yu; Nishime, Chiyoko; Kajimura, Mayumi; Jinzaki, Masahiro

    2017-12-01

    Red blood cells (RBCs) labeled with single-photon emitters have been clinically used for blood-pool imaging. Although some PET tracers have been introduced for blood-pool imaging, they have not yet been widely used. The present study investigated the feasibility of labeling RBCs with 18 F-2-deoxy-2-fluoro-D-glucose ( 18 F-FDG) for blood-pool imaging with PET. RBCs isolated from venous blood of rats were washed with glucose-free phosphate-buffered saline and labeled with 18 F-FDG. To optimize labeling efficiency, the effects of glucose deprivation time and incubation (labeling) time with 18 F-FDG were investigated. Post-labeling stability was assessed by calculating the release fraction of radioactivity and identifying the chemical forms of 18 F in the released and intracellular components of 18 F-FDG-labeled RBCs incubated in plasma. Just after intravenous injection of the optimized autologous 18 F-FDG-labeled RBCs, dynamic PET scans were performed to evaluate in vivo imaging in normal rats and intraabdominal bleeding models (temporary and persistent bleeding). The optimal durations of glucose deprivation and incubation (labeling) with 18 F-FDG were 60 and 30 min, respectively. As low as 10% of 18 F was released as the form of 18 F-FDG from 18 F-FDG-labeled RBCs after a 60-min incubation. Dynamic PET images of normal rats showed strong persistence in the cardiovascular system for at least 120 min. In the intraabdominal bleeding models, 18 F-FDG-labeled RBC PET visualized the extravascular blood clearly and revealed the dynamic changes of the extravascular radioactivity in the temporary and persistent bleeding. RBCs can be effectively labeled with 18 F-FDG and used for blood-pool imaging with PET in rats.

  5. Usefulness of brain SPECT

    International Nuclear Information System (INIS)

    Raynaud, C.; Rancurel, G.; Kieffer, E.; Ricard, S.; Askienazy, S.; Moretti, J.L.; Bourdoiseau, M.; Rapin, J.; Soussaline, F.

    1983-01-01

    Brain SPECT was not effectively exploited until I-123 isopropyl amphetamine (IAMP), indicator able to penetrate the blood brain barrier, became available. Although the experience of research teams working with IAMP is quite restricted due to the high cost of the indicator, some applications now appear to be worth the cost and in some cases provide data which cannot be obtained with routine techniques, especially in cerebrovascular patients, in epilepsy and some cases of tumor. Brain SPECT appears as an atraumatic test which is useful to establish a functional evaluation of the cerebral parenchyma, and which is a complement to arteriography, X-ray scan and regional cerebral blood flow measurement

  6. SPECT in patients with cortical visual loss.

    Science.gov (United States)

    Silverman, I E; Galetta, S L; Gray, L G; Moster, M; Atlas, S W; Maurer, A H; Alavi, A

    1993-09-01

    Single-photon emission computed tomography (SPECT) with 99mTc-hexamethylpropyleneamine oxime (HMPAO) was used to investigate changes in cerebral blood flow in seven patients with cortical visual impairment. Traumatic brain injury (TBI) was the cause of cortical damage in two patients, cerebral ischemia in two patients and carbon monoxide (CO) poisoning, status epilepticus and Alzheimer's Disease (AD) each in three separate patients. The SPECT scans of the seven patients were compared to T2-weighted magnetic resonance image (MRI) scans of the brain to determine the correlation between functional and anatomical findings. In six of the seven patients, the qualitative interpretation of the SPECT studies supported the clinical findings (i.e., the visual field defect) by revealing altered regional cerebral blood flow (rCBF) in the appropriate regions of the visual pathway. MR scans in all of the patients, on the other hand, were either normal or disclosed smaller lesions than those detected by SPECT. We conclude that SPECT may reveal altered rCBF in patients with cortical visual impairment of various etiologies, even when MRI studies are normal or nondiagnostic.

  7. High-resolution brain SPECT imaging by combination of parallel and tilted detector heads.

    Science.gov (United States)

    Suzuki, Atsuro; Takeuchi, Wataru; Ishitsu, Takafumi; Morimoto, Yuichi; Kobashi, Keiji; Ueno, Yuichiro

    2015-10-01

    To improve the spatial resolution of brain single-photon emission computed tomography (SPECT), we propose a new brain SPECT system in which the detector heads are tilted towards the rotation axis so that they are closer to the brain. In addition, parallel detector heads are used to obtain the complete projection data set. We evaluated this parallel and tilted detector head system (PT-SPECT) in simulations. In the simulation study, the tilt angle of the detector heads relative to the axis was 45°. The distance from the collimator surface of the parallel detector heads to the axis was 130 mm. The distance from the collimator surface of the tilted detector heads to the origin on the axis was 110 mm. A CdTe semiconductor panel with a 1.4 mm detector pitch and a parallel-hole collimator were employed in both types of detector head. A line source phantom, cold-rod brain-shaped phantom, and cerebral blood flow phantom were evaluated. The projection data were generated by forward-projection of the phantom images using physics models, and Poisson noise at clinical levels was applied to the projection data. The ordered-subsets expectation maximization algorithm with physics models was used. We also evaluated conventional SPECT using four parallel detector heads for the sake of comparison. The evaluation of the line source phantom showed that the transaxial FWHM in the central slice for conventional SPECT ranged from 6.1 to 8.5 mm, while that for PT-SPECT ranged from 5.3 to 6.9 mm. The cold-rod brain-shaped phantom image showed that conventional SPECT could visualize up to 8-mm-diameter rods. By contrast, PT-SPECT could visualize up to 6-mm-diameter rods in upper slices of a cerebrum. The cerebral blood flow phantom image showed that the PT-SPECT system provided higher resolution at the thalamus and caudate nucleus as well as at the longitudinal fissure of the cerebrum compared with conventional SPECT. PT-SPECT provides improved image resolution at not only upper but also at

  8. Radiopharmaceuticals for brain - SPECT

    International Nuclear Information System (INIS)

    Moretti, J.L.

    1992-01-01

    Perfusion tracers for brain SPECT imaging suitable for regional cerebral blood flow measurement and regional cerebral blood volume determination, with respect to their ability to pass the blood-brain-barrier, are described. Problems related t the use of specific radiotracers to map receptors distribution in the brain are also discussed in this lecture. 9 figs, 6 tabs

  9. /sup 99m/Tc dextran: a new blood-pool-labeling agent for radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Henze, E.; Robinson, G.D.; Kuhl, D.E.; Schelbert, H.R.

    1982-01-01

    We have explored the possibility of imaging the cardiac blood pool with dextran (Dx) labeled with /sup 99m/Tc (Tc) after Sn2+ reduction. Stannous dextran (SnDx) kits were prepared in advance and labeling was performed by adding /sup 99m/Tc. The labeling efficiency was greater than 95%. /sup 99m/Tc dextran (TcDx) was highly stable both in vivo and in vitro. In seven dogs we compared the quality of blood-pool images obtained with TcDx of different molecular weights (4 X 10(4) . Dx-40; 5 X 10(5) . Dx-500; 2 X 10(6) . Dx-2000) and with /sup 99m/Tc red blood cells (TcRBC) labeled in vitro, and determined the organ distribution of this new agent by whole-body scanning and blood sampling. TcDx provided high-quality cardiac blood-pool images up to 60 min after injection. The heart-to-lung ratios averaged 3.7 for TcDx-40, 3.9 for TcDx-500, and 5.4 for TcRBC at 60 min. Whereas TcDx-40 showed a relatively rapid initial urinary excretion and TcDx-2000 was degraded rapidly, TcDx-500 demonstrated the best kinetics for blood-pool imaging. Thus, TcDx is a new radiopharmaceutical with high labeling efficiency and stability. It overcomes a number of the limitations of currently used blood-labeling agents and may become useful for blood-pool imaging in man

  10. {sup 99m}Tc-HMPAO Brain SPECT in Seizure Disorder: Comparison Brain SPECT, MRI / CT and EEG

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Hyung In [Kyunghee University Hospital, Seoul (Korea, Republic of); Im, Ju Hyuk; Choi, Chang Woon; Lee, Dong Soo; Chung, June Key; No, Jae Kyu; Lee, Myung Chul; Koh, Chang Soon [Seoul National University Hospital, Seoul (Korea, Republic of)

    1994-03-15

    We studied 115 patients with seizure who had been performed brain SPECT brain MRI of CT and EEG. To evaluate the pattern of brain SPECT in seizure patients 28 of them had secondary epilepsies, 87 had primary epilepsies. In primary epilepsies, 42 were generalized seizure and 45 were partial seizure. The causes of secondary epilepsies were congenital malformation, cerebromalacia, cerebral infarction ultiple sclerosis, AV-malformation. granuloma and etc, in order. In 28 secondary epilepsies, 25 of them, brain SPECT lesions was concordant with MRI or CT lesions. 3 were disconcordant. The brain SPECT findings of generalized seizure were normal in 22 patients, diffuse irregular decreased perfusion in 8, decreased in frontal cortex in 4. temporal in 5 and frontotemporal in 3. In 45 partial seizure, 19 brain SPECT were concordant with EEG (42.4%).

  11. rCBF SPECT in Parkinson's disease patients with mental dysfunction

    International Nuclear Information System (INIS)

    Bissessur, S.; Tissingh, G.; Wolters, E.C.; Scheltens, P.

    1997-01-01

    Functional imaging of the brain using SPECT provides information correlative to the alterations of regional blood flow. In this paper we review the literature pertaining to SPECT in Parkinson's disease with and without dementia and depression. Parkinson's disease itself is not associated with a consistent pattern of cerebral blood flow alterations in the basal ganglia, but reduced parietal blood flow is more often reported. The heterogeneity of blood flow changes possibly reflects the multifactorial pathophysiology of the disease. In demented Parkinson's disease patients frontal hypoperfusion is often found or bilateral temporoparietal deficits, probably indicative of concomitant Alzheimer's disease. The SPECT studies undertaken in depressed patients with and without Parkinson's disease show highly conflicting and inconsistent results, probably due to methodological and diagnostic flaws (especially the inclusion of demented Parkinson patients). Several lines of reasoning point to a prefrontal dysfunction and future SPECT studies are planned to study this region in non-demented Parkinson's disease patients with and without major depression. (author)

  12. Diagnosis of an isolated occult fracture of the posterior margin of the tibia with the SPECT/CT

    International Nuclear Information System (INIS)

    Bourdon, A.; Granier, P.; Mourad, M.

    2007-01-01

    We report the case of a 56-year-old woman, investigated for pains of the right ankle related to a trauma of an unspecified mechanism. The radiographic assessment was negative. The 99m Tc-HDP 3-phase bone scintigraphy highlighted, on the blood pool and the delayed images, a located lesion on the right ankle. The single photon emission computerized tomography guided by computerized tomography (SPECT-CT) showed a focused uptake on the posterior margin of the right tibia and a sharp lucent line within the tomo-scintigraphy spot of uptake. The diagnosis accepted was an isolated occult fracture of the posterior margin of the right tibia. The contribution of the 99m Tc-HDP 3-phase bone scintigraphy combined with the SPECT-CT in the diagnosis of the occult fractures is discussed. (N.C.)

  13. Myocardial perfusion SPECT for assessment of left ventricular function and volume- comparison with echocardiography

    International Nuclear Information System (INIS)

    Cheng Xu; Huang Gang

    2004-01-01

    Objective: The purpose of this study was to evaluate left ventricular volume and function by gated SPECT and comparison of the results with echocardiography. Methods: 65 Consecutive patients (49 male, 16 female; mean age 61+11 years) who underwent both gated 99m Tc-MIBI myocardial perfusion SPECT and echocardiography within a 15 days period were included in the study. Exclusion criteria were any change in clinical status between acquisition of the gated SPECT and echocardiography studies, acute myocardial infarction occurring less than 7 days before study, and surgical procedures occurring within 30 days of the study. The clinical diagnosis of each patient was not considered, as this was not relevant to the purpose of the study. The diagnoses were as follows: coronary artery disease (n=46), hypertensive heart disease (n=8), old myocardial infarction (n=5), myocarditis (n=2), and routine medical examination(n=4). A dose of 740 MBq of 99 Tc m -sestamibi was administered in resting condition. Gated SPECT images were obtained with ADAC Vertex MCD-AC SPECT system. The raw projection images were reconstructed with filtered back-projection (ramp filter), without attenuation correction. The data, including left ventricular ejection fraction (LVEF), end-diastolic volume (EDV), end-systolic volume (ESV) were obtained using AUTOQUANT software (ADAC corporation). The echocardiography study used its standard techniques. Two nuclear medicine physicians processed the raw images respectively to evaluate internal reproducibility of gated SPECT. In order to compare the results of gated SPECT with echocardiography on different left ventricular volumes, all patients were divided into two groups (EDV 90 ml, n=34) based by EDV measurements in echocardiography. Results: The correlation coefficient of LVEF, EDV, ESV between SPECT and echocardiography were 0.77, 0.86 and 0.90 respectively. P 0.07). The reproducibility of gated SPECT was excellent. There were no significant differences in

  14. Phase analysis in gated blood pool tomography. Detection of accessory conduction pathway

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Kenichi; Bunko, Hisashi; Tada, Akira; Taki, Junichi; Nanbu, Ichiro (Kanazawa Univ. (Japan). School of Medicine)

    1984-02-01

    Phase analysis of gated blood pool study has been applied to detect the site of accessory conduction pathway (ACP) in the Wolff-Parkinson-White (WPW) syndrome; however, there was a limitation to detect the precise location of ACP by phase analysis alone. In this study, we applied phase analysis to gated blood pool tomography using seven pin hole tomography (7PT) and gated emission computed tomography (GECT) in 21 patients with WPW syndrome and 3 normal subjects. In 17 patients, the sites of ACPs were confirmed by epicardial mapping and the result of the surgical division of ACP. In 7PT, the site of ACP grossly agreed to the abnormal initial phase in phase image in 5 out of 6 patients with left cardiac type. In GECT, phase images were generated in short axial, vertical and horizontal long axial sections. In 8 out of 9 patients, the site of ACP was correctly identified by phase images, and in a patient who had two ACPs, initial phase corresponded to one of the two locations. Phase analysis of gated blood pool tomography has advantages for avoiding overlap of blood pools and for estimating three-dimensional propagation of the contraction, and can be a good adjunctive method in patients with WPW syndrome.

  15. Regional cerebral blood flow measurements by a noninvasive microsphere method using 123I-IMP. Comparison with the modified fractional uptake method and the continuous arterial blood sampling method

    International Nuclear Information System (INIS)

    Nakano, Seigo; Matsuda, Hiroshi; Tanizaki, Hiroshi; Ogawa, Masafumi; Miyazaki, Yoshiharu; Yonekura, Yoshiharu

    1998-01-01

    A noninvasive microsphere method using N-isopropyl-p-( 123 I)iodoamphetamine ( 123 I-IMP), developed by Yonekura et al., was performed in 10 patients with neurological diseases to quantify regional cerebral blood flow (rCBF). Regional CBF values by this method were compared with rCBF values simultaneously estimated from both the modified fractional uptake (FU) method using cardiac output developed by Miyazaki et al. and the conventional method with continuous arterial blood sampling. In comparison, we designated the factor which converted raw SPECT voxel counts to rCBF values as a CBF factor. A highly significant correlation (r=0.962, p<0.001) was obtained in the CBF factors between the present method and the continuous arterial blood sampling method. The CBF factors by the present method were only 2.7% higher on the average than those by the continuous arterial blood sampling method. There were significant correlation (r=0.811 and r=O.798, p<0.001) in the CBF factor between modified FU method (threshold for estimating total brain SPECT counts; 10% and 30% respectively) and the continuous arterial blood sampling method. However, the CBF factors of the modified FU method showed 31.4% and 62.3% higher on the average (threshold; 10% and 30% respectively) than those by the continuous arterial blood sampling method. In conclusion, this newly developed method for rCBF measurements was considered to be useful for routine clinical studies without any blood sampling. (author)

  16. SPECT with [99mTc]-d,l-hexamethyl-propylene amine oxime (HM-PAO) compared with regional cerebral blood flow measured by PET

    DEFF Research Database (Denmark)

    Yonekura, Y; Nishizawa, S; Mukai, Thomas Søgaard

    1988-01-01

    In order to validate the use of technetium-99m-d,l-hexamethylpropyleneamine oxime (HM-PAO) as a flow tracer, a total of 21 cases were studied with single photon emission computerized tomography (SPECT), and compared to regional cerebral blood flow (rCBF) measured by position emission tomography...... (PET) using the oxygen-15 CO2 inhalation technique. Although HM-PAO SPECT and rCBF PET images showed a similar distribution pattern the HM-PAO SPECT image showed less contrast between high and low activity flow regions than the rCBF image and a nonlinear relationship between HM-PAO activity and r......CBF was shown. Based on the assumption of flow-dependent backdiffusion of HM-PAO from the brain, we applied a "linearization algorithm" to correct the HM-PAO SPECT images. The corrected HM-PAO SPECT images revealed a good linear correlation with rCBF (r = 0.901, p less than 0.001). The results indicated HM-PAO...

  17. Assessment of left ventricular function by electrocardiogram-gated myocardial single photon emission computed tomography using quantitative gated single photon emission computed tomography software

    International Nuclear Information System (INIS)

    Morita, Koichi; Adachi, Itaru; Konno, Masanori

    1999-01-01

    Electrocardiogram (ECG)-gated myocardial single photon emission computed tomography (SPECT) can assess left ventricular (LV) perfusion and function easily using quantitative gated SPECT (QGS) software. ECG-gated SPECT was performed in 44 patients with coronary artery disease under post-stress and resting conditions to assess the values of LV functional parameters, by comparison to LV ejection fraction derived from gated blood pool scan and myocardial characteristics. A good correlation was obtained between ejection fraction using QGS and that using cardiac blood pool scan (r=0.812). Some patients with myocardial ischemia had lower ejection fraction under post-stress compared to resting conditions, indicating post-stress LV dysfunction. LV wall motion and wall thickening were significantly impaired in ischemic and infarcted myocardium, and the degree of abnormality in the infarcted areas was greater than in the ischemia area. LV functional parameters derived using QGS were useful to assess post-stress LV dysfunction and myocardial viability. In conclusion, ECG-gated myocardial SPECT permits simultaneous quantitative assessment of myocardial perfusion and function. (author)

  18. Regional cerebral blood flow in epileptic foci using [I-123] IMP-SPECT

    International Nuclear Information System (INIS)

    Konishi, Tohru

    1989-01-01

    Fifty-six epileptic patients, whose ages ranged from 6 months to 16 years (a mean age, 8 years and 2 months), were examined by single photon emission computed tomography (SPECT) with [I-123] N-isopropyl p-iodoamphetamine (IMP). Of these patients, 44 had partial seizures (PS) and 12 had generalized seizures (GS). SPECT revealed abnormality of regional cerebral blood flow (rCBF) in 24 PS patients (54.5%), being correlated with EEG abnormality. Among the 24 patients, 22 had a decreased rCBF and 2 others had an increased rCBF. According to the PS type, rCBF abnormality in the foci was less frequently observed for benign age-related partial epilepsy (2/9) than for the other types of partial epilepsy (22/35). Among 35 patients with the other types of partial epilepsy, SPECT showed foci in the frontal (12), central (3), parietal (4), temporal (6), and occipital (6) regions, and diffuse spike-wave or the lack of paroaxysmals (4). The EEG foci was of the left hemisphere in 12 patients, and of the right hemisphere in 18 patients. Higher incidence of rCBF abnormality was associated with the temporal, partietal, and frontal foci than with the occipital foci. There was no correlation between the incidence of rCBF abnormlaity and the frequency of seizure activities on EEG. Complex partial seizures had a tendency to be associated with rCBF abnormality. In comparing IMP uptake in evaluable 17 patients with a decreased rCBF, a mean %CBF in foci compared to that in the contralateral area was 91.9%. All of the 12 GS patients showed no focal reduction of rCBF around the cortex. Patients with tonic-clonic seizure and myoclonic seizure had almost normal IMP images. The IMP images of organic lesions were a marked reduction of rCBF. IMP-SPECT may also be suitable for evaluating the underlying organic and secondary involving disorders with epilepsy. (N.K.)

  19. Cardiac blood pool emission tomography

    International Nuclear Information System (INIS)

    Itti, R.; Philippe, L.; Lorgeron, J.M.; Charbonnier, B.; Raynaud, P.; Brochier, M.

    1983-01-01

    After blood pool labeling using technetium-99m, a series of cardiac pictures is acquired during the rotation of a gamma-camera about the patient. Computer processing leads to reconstruction of various tomographic slices from the original planar projection. Electrocardiographic gating selects the different phases of the cardiac cycle. Individual slices through the left ventricular region are added in order to provide ''thick'' slices on which global and regional parameters of the left ventricular function can be determined. Due to the proportionality existing between count rates and labeled blood volumes, any geometrical model can be avoided. The delineation of regions of interest for count integration is made easier due to the absence of superimposition of structures; no correction for background is necessary. Tomography thus appears to be more consistent and more accurate than the classical methods using planar projections. In addition, right ventricular morphological and kinetic studies can be performed in the same conditions as for the left ventricle [fr

  20. Cerebral blood flow of the non-affected brain in patients with malignant brain tumors as studied by SPECT

    International Nuclear Information System (INIS)

    Araki, Yuzo; Imao, Yukinori; Hirata, Toshifumi; Ando, Takashi; Sakai, Noboru; Yamada, Hiroshi

    1990-01-01

    In 40 patients (age range, 20-69 years) receiving radiation and chemotherapy for brain tumors, the mean cerebral blood flow (mCBF) in the non-affected area has been examined by single photon emission CT (SPECT) with Xe-133. Forty volunteers (age range, 25-82 years) served as controls. Although mCBF during external irradiation was transiently increased, it was significantly decreased at 3 months after beginning of external irradiation compared with that in the control group. Factors responsible for the decrease in mCBF were radiation doses, lesion volume, the degree of cerebral atrophy, and age; this was more pronounced when chemotherapy such as ACNU was combined with radiation. A decreased mCBF was independent of intraoperative radiation combined with external radiation and either local or whole brain irradiation. SPECT with Xe-133 was useful in determining minute changes in cerebral blood flow that precedes parenchymal brain damage. (N.K.)

  1. Absolute quantitation of myocardial blood flow with 201Tl and dynamic SPECT in canine: optimisation and validation of kinetic modelling

    International Nuclear Information System (INIS)

    Iida, Hidehiro; Kim, Kyeong-Min; Nakazawa, Mayumi; Sohlberg, Antti; Zeniya, Tsutomu; Hayashi, Takuya; Watabe, Hiroshi; Eberl, Stefan; Tamura, Yoshikazu; Ono, Yukihiko

    2008-01-01

    201 Tl has been extensively used for myocardial perfusion and viability assessment. Unlike 99m Tc-labelled agents, such as 99m Tc-sestamibi and 99m Tc-tetrofosmine, the regional concentration of 201 Tl varies with time. This study is intended to validate a kinetic modelling approach for in vivo quantitative estimation of regional myocardial blood flow (MBF) and volume of distribution of 201 Tl using dynamic SPECT. Dynamic SPECT was carried out on 20 normal canines after the intravenous administration of 201 Tl using a commercial SPECT system. Seven animals were studied at rest, nine during adenosine infusion, and four after beta-blocker administration. Quantitative images were reconstructed with a previously validated technique, employing OS-EM with attenuation-correction, and transmission-dependent convolution subtraction scatter correction. Measured regional time-activity curves in myocardial segments were fitted to two- and three-compartment models. Regional MBF was defined as the influx rate constant (K 1 ) with corrections for the partial volume effect, haematocrit and limited first-pass extraction fraction, and was compared with that determined from radio-labelled microspheres experiments. Regional time-activity curves responded well to pharmacological stress. Quantitative MBF values were higher with adenosine and decreased after beta-blocker compared to a resting condition. MBFs obtained with SPECT (MBF SPECT ) correlated well with the MBF values obtained by the radio-labelled microspheres (MBF MS ) (MBF SPECT = -0.067 + 1.042 x MBF MS , p 201 Tl and dynamic SPECT. (orig.)

  2. Clinical evaluation of SPECT in cerebrovascular disease

    International Nuclear Information System (INIS)

    Oshibuchi, Masao; Satoh, Mitsutaka; Kanda, Tetsuro; Nishi, Fumiaki; Yamane, Kanji; Fujimatsu, Masahiko; Edamitsu, Satoshi; Anno, Yasuro; Ohtake, Hisashi.

    1989-01-01

    In 131 patients with cerebrovascular disease, regional cerebral blood flow were determined by 123 I-IMP (N-isopropyl ( 123 I)-iodoamphetamine) or 99m Tc-HM-PAO ( 99m Tc (d, 1)-hexamethyl propyleneamine oxime) SPECT and findings were compared with those of X-CT or MRI. The perfusion deficit detected by SPECT was larger than the deficit by X-CT or MRI in every case. The perfusion deficit area was more clearly demonstrated by SPECT than by X-CT or MRI in patients with acute cerebral infarction. The hypoperfusion area determined by 123 I-IMP SPECT was wider than that by 99m Tc-HM-PAO SPECT. The crossed cerebellar diaschisis was observed in 56 out of 131 cases (43%). The results of operation were quantitatively evaluated by 123 I-IMP SPECT in 25 patients. (author)

  3. 99mTc-ECD brain perfusion SPECT in hyperalgesic fibromyalgia

    International Nuclear Information System (INIS)

    Guedj, Eric; Taieb, David; Cammilleri, Serge; Lussato, David; Laforte, Catherine de; Mundler, Olivier; Niboyet, Jean

    2007-01-01

    Neuro-imaging studies with 99m Tc-HMPAO SPECT in fibromyalgia (FM) patients have reported only limited subcortical hypoperfusion. 99m Tc-ECD SPECT is known to provide better evaluation of areas of high cerebral blood flow and regional metabolic rate. We evaluated a homogeneous group of hyperalgesic patients with FM using 99m Tc-ECD SPECT. The aim of this study was to investigate brain processing associated with spontaneous pain in FM patients. Eighteen hyperalgesic FM women (mean age 49 years, range 25-63 years; American College of Rheumatology criteria) and ten healthy women matched for age were enrolled in the study. A voxel-by-voxel group analysis was performed using SPM2 (p<0.05, corrected for multiple comparisons). Visual Analogue Scale score for pain was 82±4 at the time of the SPECT study. Compared with control subjects, we observed individual brain SPECT abnormalities in FM patients, confirmed by SPM2 analysis, with hyperperfusion of the somatosensory cortex and hypoperfusion of the frontal, cingulate, medial temporal and cerebellar cortices. In the present study, performed without noxious stimuli in hyperalgesic FM patients, we found significant hyperperfusion in regions of the brain known to be involved in the sensory dimension of pain processing and significant hypoperfusion in areas assumed to be associated with the affective-attentional dimension. As current pharmacological and non-pharmacological therapies act differently on the two components of pain, we hypothesise that SPECT could be a valuable and readily available tool to guide individual therapeutic strategy and provide objective follow-up of pain processing recovery under treatment. (orig.)

  4. Advances in regional cerebral blood flow measurement and patho-physiological analysis by SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Odano, Ikuo [Niigata Univ. (Japan). School of Medicine

    1994-04-01

    Recently, two kinds of radiopharmaceuticals have been developed to represent the biodistribution of regional blood flow, which are N-isopropyl-p-[[sup 123]I]iodoamphetamine (IMP) and [sup 99m]Tc-hexamethylpropylene-amine-oxime (HMPAO). The charachteristics, clinical usage and imitation of these two radiolabeled agents are discussed. The advantage of [sup 123]I-IMP is that it has high first-pass extraction and long retention in brain tissue, hence it can be used to measure the absolute values of regional cerebral blood flow (rCBF). When the kinetics of [sup 123]I-IMP is assumed to be freely diffusible in the brain, its behavior is considered by 2-compartment model, especially which is assumed by the microsphere model in the early period after the i.v. injection of [sup 123]I-IMP. Comparing the rCBF measured by [sup 123]I-IMP with that by [sup 133]Xe inhalation SPECT method, we have to consider PaCO[sub 2] when both SPECT studies are performed, because PaCO[sub 2] is one of the big factors which make effects on the alteration of rCBF. [sup 123]I-IMP has an interesting character of the redistribution phenomenon which represrent the degree of ischemia in the cerebrovascular diseases. Distribution volume an important datum obtained by the SPECT study with [sup 123]I-IMP, which represent the degree of retention, i.e. binding potential of [sup 123]I-IMP in the brain tissue. I introduced the usage of the distribution volume of [sup 123]I-IMP, which was constructed in the rate constant square method, in the differential diagnosis of Parkinson's disease and progressive supranuclear palsy (PSP). The clinical usage of [sup 99m] Tc-HMPAT was mentioned, the advantage of which is the rapid fixation in the brain tissue and the distribution does not change for long time after the i.v. injection. Hence [sup 99m]Tc-HMPAO is used for the diagnosis of epileptic foci and certain loading tests such as balloon occlusion test, postural test and acetazolamide loading test. (author).

  5. Applications of cerebral SPECT

    Energy Technology Data Exchange (ETDEWEB)

    McArthur, C., E-mail: claire.mcarthur@nhs.net [Department of Neuroradiology, Institute of Neurological Sciences, Glasgow (United Kingdom); Jampana, R.; Patterson, J.; Hadley, D. [Department of Neuroradiology, Institute of Neurological Sciences, Glasgow (United Kingdom)

    2011-07-15

    Single-photon emission computed tomography (SPECT) can provide three-dimensional functional images of the brain following the injection of one of a series of radiopharmaceuticals that crosses the blood-brain barrier and distributes according to cerebral perfusion, neurotransmitter, or cell density. Applications include differentiating between the dementias, evaluating cerebrovascular disease, preoperative localization of epileptogenic foci, diagnosing movement disorders, and evaluation of intracerebral tumours, while also proving a useful research tool. Unlike positronemission tomography (PET), SPECT imaging is widely available and can be performed in any department that has access to a rotating gamma camera. The purpose of this review is to demonstrate the utility of cerebral SPECT and increase awareness of its role in the investigation of neurological and psychiatric disorders.

  6. AMINO ACID BLOOD POOL OF CHILDREN WITH ALLERGIC DISEASES

    Directory of Open Access Journals (Sweden)

    Shmulich O. V.

    2014-01-01

    Full Text Available The amino acid blood pool of children with atopic dermatitis, bronchial asthma, urticaria, angioedema was investigated. The variability of blood plasma amino acid content (tryptophan, histidine, tyrosine, cysteine, methionine was observed. The changes of histidine and tryptophan levels might be connected with the formation of biogenic amines, such as histamine, serotonine, with take part in the development of allergic reactions and inflammatory processes in organism.

  7. Comparison of 133Xe gas dynamic SPECT and thin-section CT in patients with pulmonary emphysema

    International Nuclear Information System (INIS)

    Takahashi, Kazue; Satoh, Katashi; Ohkawa, Motoomi

    2001-01-01

    We assessed 133 Xe gas dynamic single photon emission computed tomography (SPECT) by comparing washout axial images with thin-section CT (TSCT) in patients with pulmonary emphysema. Twenty-three patients were studied. All patients were diagnosed as having pulmonary emphysema on the basis of TSCT. We compared TSCT of upper, middle and lower lung fields with 133 Xe gas dynamic SPECT axial images at the corresponding levels during the 3 to 4 minutes of washout phase. If the degree of 133 Xe gas retention or TSCT finding of ventral and dorsal parts was not the same, the images were divided into two parts. A total of 174 lesions in 23 cases were examined, but 3 lesions having no retention of 133 Xe gas at equilibrium phase were excluded. The results showed that: there were 37 lesions (21.6%) with equivalent severity on both images; there were 42 lesions (24.5%) with more severity on 133 Xe gas dynamic SPECT than on TSCT; and there were 92 lesions (53.8%) with more severity on TSCT than on 133 Xe gas dynamic SPECT. The severity on 133 Xe gas dynamic SPECT and TSCT was not always compatible. One of the reasons for the variable 133 Xe gas retention even when the lesion had the same severity on TSCT, may be bronchial stricture which cannot be seen on TSCT. By comparison of axial images of 133 Xe gas dynamic SPECT with CT images, we could recognize the areas of 133 Xe gas retention in detail. Results suggest that 133 Xe gas dynamic SPECT can be useful to identify ventilation impairment in pulmonary emphysema. (author)

  8. Benzodiazepine receptor and cerebral blood flow in early Alzheimer's disease. SPECT study using 123I-Iomazenil and 123I-IMP

    International Nuclear Information System (INIS)

    Kitamura, Shin; Koshi, Yasuhiko; Komiyama, Tasuku; Sakayori, Osamu; Komaba, Yuichi; Ohyama, Masashi; Mishina, Masahiro; Tsuganesawa, Toshikazu; Terashi, Akiro

    1996-01-01

    This study was designed to investigate benzodiazepine receptors (BZR) and cerebral blood flow (CBF) in patients with early Alzheimer's disease. Imaging of BZR and measurement of CBF were performed by SPECT using 123 I-Iomazenil (IMZ) and 123 I-IMP respectively, in seven patients with early Alzheimer's disease and five patients with unilateral left cerebral infarction as controls. The values for the normal cerebral hemisphere (ratio to the contralateral cerebellum) in patients with cerebral infarction were adopted as control values. In patients with Alzheimer's disease, the CBF (ratio to cerebellum) decreased significantly in the frontal cortex and the parietal cortex compared with the control values. There was no significant difference in late IMZ SPECT counts (ratio to cerebellum) and washout (the ratio of late-to-early IMZ SPECT counts) between patients with Alzheimer's disease and the controls. However, the late IMZ SPECT counts and washout decreased in one patient with moderate dementia. There was a significant correlation between the severity of dementia and the late IMZ SPECT counts in the temporal cortex and the parietal cortex. These results suggest that benzodiazepine binding sites are relatively well preserved in patients with early Alzheimer's disease, and reduction of the CBF is caused by neuronal dysfunction rather than by neuronal loss. IMZ SPECT study is useful and necessary for clarifying the pathophysiological state in Alzheimer's disease. (author)

  9. Differences in lateral hemispheric asymmetries of cerebral blood flow measured by SPECT in dementia of Alzheimer type

    Energy Technology Data Exchange (ETDEWEB)

    Yoshimura, Nahoko [Niigata Univ. (Japan). School of Medicine

    1993-12-01

    We studied 21 right-handed patients clinically diagnosed as dementia of Alzheimer type (8 men, 13 women; aged 53-85, mean 71.1 years). The average duration of symptoms was 2.7 years. Dementia ranged from mild to moderately severe. None had clinical or laboratory evidence of cerebro-vascular disease (Hachinski ischemic scores for all patients were 4 or below). All received the Wechsler Adult Intelligence Scale (WAIS), Mini-mental State Test (MMS) and Western Aphasia Battery (WAB, First Japanese edition, 1986). Regional cerebral blood flow was evaluated by single photon emission CT (SPECT) with [sup 123]I-N-isopropyl-p-iodoamphetamine ([sup 123]I-IMP), using the Matsuda's quantitative method. The subjects were divided into three groups on the basis of right-left hemispheric asymmetry of cerebral blood flow (leftblood flow. Verbal IQ in patients with predominant hypoperfusion of left temporal and parietal lobe were significantly lower than in other groups, while performance IQ and WAB constructive scores were lower in those with right hemispheric hypoperfusion (p<0.05). We concluded that cerebral blood flow asymmetry detected by SPECT was related significantly to the deficit of language and constructive function in patients with dementia of Alzheimer type. (author).

  10. Differences in lateral hemispheric asymmetries of cerebral blood flow measured by SPECT in dementia of Alzheimer type

    Energy Technology Data Exchange (ETDEWEB)

    Yoshimura, Nahoko (Niigata Univ. (Japan). School of Medicine)

    1993-12-01

    We studied 21 right-handed patients clinically diagnosed as dementia of Alzheimer type (8 men, 13 women; aged 53-85, mean 71.1 years). The average duration of symptoms was 2.7 years. Dementia ranged from mild to moderately severe. None had clinical or laboratory evidence of cerebro-vascular disease (Hachinski ischemic scores for all patients were 4 or below). All received the Wechsler Adult Intelligence Scale (WAIS), Mini-mental State Test (MMS) and Western Aphasia Battery (WAB, First Japanese edition, 1986). Regional cerebral blood flow was evaluated by single photon emission CT (SPECT) with [sup 123]I-N-isopropyl-p-iodoamphetamine ([sup 123]I-IMP), using the Matsuda's quantitative method. The subjects were divided into three groups on the basis of right-left hemispheric asymmetry of cerebral blood flow (leftblood flow. Verbal IQ in patients with predominant hypoperfusion of left temporal and parietal lobe were significantly lower than in other groups, while performance IQ and WAB constructive scores were lower in those with right hemispheric hypoperfusion (p<0.05). We concluded that cerebral blood flow asymmetry detected by SPECT was related significantly to the deficit of language and constructive function in patients with dementia of Alzheimer type. (author).

  11. Differences in lateral hemispheric asymmetries of cerebral blood flow measured by SPECT in dementia of Alzheimer type

    International Nuclear Information System (INIS)

    Yoshimura, Nahoko

    1993-01-01

    We studied 21 right-handed patients clinically diagnosed as dementia of Alzheimer type (8 men, 13 women; aged 53-85, mean 71.1 years). The average duration of symptoms was 2.7 years. Dementia ranged from mild to moderately severe. None had clinical or laboratory evidence of cerebro-vascular disease (Hachinski ischemic scores for all patients were 4 or below). All received the Wechsler Adult Intelligence Scale (WAIS), Mini-mental State Test (MMS) and Western Aphasia Battery (WAB, First Japanese edition, 1986). Regional cerebral blood flow was evaluated by single photon emission CT (SPECT) with 123 I-N-isopropyl-p-iodoamphetamine ( 123 I-IMP), using the Matsuda's quantitative method. The subjects were divided into three groups on the basis of right-left hemispheric asymmetry of cerebral blood flow (left< right, n=6; right< left, n=3; left=right, n=12). General scores (MMS, T-IQ) were not correlated with asymmetry of cerebral blood flow. Verbal IQ in patients with predominant hypoperfusion of left temporal and parietal lobe were significantly lower than in other groups, while performance IQ and WAB constructive scores were lower in those with right hemispheric hypoperfusion (p<0.05). We concluded that cerebral blood flow asymmetry detected by SPECT was related significantly to the deficit of language and constructive function in patients with dementia of Alzheimer type. (author)

  12. Comparison of Tc-99m HM-PAO SPECT brain scan and x-ray CT in the detection of brain metastases

    International Nuclear Information System (INIS)

    Abdel-Dayem, H.M.; Sadek, S.; Sahwell, A.; Kubasek, H.; El-Sayed, M.; Ziada, G.; Mobarak, L.; Al-Huda, F.; Omar, Y.T.

    1986-01-01

    Tc-99m HM-PAO imaging was compared with x-ray CT in 14 patients with known or suspected brain metastases. Both studies were done within 3 days of each other. Static and single photon emission CT (SPECT) images were acquired after intravenous injection of 13 mCi of Tc-99m HM-PAO. All 14 patients underwent static and SPECT Tc-99m HM-PAO imaging and x-ray CT. Studies were positive in 7, 12, and 10 patients, respectively, by static, SPECT, and x-ray CT imaging, and negative in 7, 2, and 2. The number of lesions identified was 0 (static imaging), 32 (SPECT), and 26(x-ray CT). There were no ''suspicious'' studies by any modality. This study indicates that Tc-99m HM-PAO SPECT cerebral blood flow imaging is more sensitive than x-ray CT for detecting brain metastases, that biplane imaging is not sensitive and SPECT is essential, and that for Tc-99m HM-PAO SPECT brain imaging to regain its importance with respect to x-ray CT, acquisition time must be 10 minutes or less and determination of percentage brain uptake of the injected dose, and of regional distribution, is necessary

  13. N-isopropyl-p-[123I]iodoamphetamine SPECT in MELAS syndrome: Comparison with CT and MR imaging

    International Nuclear Information System (INIS)

    Satoh, M.; Ishikawa, N.; Yoshizawa, T.; Takeda, T.; Akisada, M.

    1991-01-01

    Regional cerebral perfusion was studied in three patients with the mitochondrial encephalomyopathy with lactic acidosis and stroke-like episodes (MELAS) syndrome, using single photon emission computed tomography (SPECT) with N-isopropyl-p-[123I]iodoamphetamine (IMP). Accumulation of the tracer was relatively decreased in the parietooccipital regions and also in the frontotemporal regions after stroke-like episodes. However, quantitative regional cerebral blood flow (rCBF) measurement showed that rCBF was relatively well preserved even at these sites, and a hyperemic state was observed at the sites of normal accumulation. IMP SPECT may be useful in the diagnosis and assessment of the progress of the MELAS syndrome

  14. Intra-image referencing for simplified assessment of HER2-expression in breast cancer metastases using the Affibody molecule ABY-025 with PET and SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Sandberg, Dan; Tolmachev, Vladimir; Olofsson, Helena; Carlsson, Joergen; Lindman, Henrik [Uppsala University, Department of Immunology, Genetics and Pathology, Uppsala (Sweden); Velikyan, Irina; Soerensen, Jens [Uppsala University, Section of Nuclear Medicine and PET, Department of Surgical Sciences, Uppsala (Sweden); Wennborg, Anders; Feldwisch, Joachim [Affibody AB, Solna (Sweden)

    2017-08-15

    In phase I/II-studies radiolabelled ABY-025 Affibody molecules identified human epidermal growth factor receptor 2 (HER2) expression in breast cancer metastases using PET and SPECT imaging. Here, we wanted to investigate the utility of a simple intra-image normalization using tumour-to-reference tissue-ratio (T/R) as a HER2 status discrimination strategy to overcome potential issues related to cross-calibration of scanning devices. Twenty-three women with pre-diagnosed HER2-positive/negative metastasized breast cancer were scanned with [{sup 111}In]-ABY-025 SPECT/CT (n = 7) or [{sup 68}Ga]-ABY-025 PET/CT (n = 16). Uptake was measured in all metastases and in normal spleen, lung, liver, muscle, and blood pool. Normal tissue uptake variation and T/R-ratios were established for various time points and for two different doses of injected peptide from a total of 94 whole-body image acquisitions. Immunohistochemistry (IHC) was used to verify HER2 expression in 28 biopsied metastases. T/R-ratios were compared to IHC findings to establish the best reference tissue for each modality and each imaging time-point. The impact of shed HER2 in serum was investigated. Spleen was the best reference tissue across modalities, followed by blood pool and lung. Spleen-T/R was highly correlated to PET SUV in metastases after 2 h (r = 0.96,P < 0.001) and reached an accuracy of 100% for discriminating IHC HER2-positive and negative metastases at 4 h (PET) and 24 h (SPECT) after injection. In a single case, shed HER2 resulted in intense tracer retention in blood. In the remaining patients shed HER2 was elevated, but without significant impact on ABY-025 biodistribution. T/R-ratios using spleen as reference tissue accurately quantify HER2 expression with radiolabelled ABY-025 imaging in breast cancer metastases with SPECT and PET. Tracer binding to shed HER2 in serum might affect quantification in the extreme case. (orig.)

  15. Self-Assembled Nanomicelles as MRI Blood-Pool Contrast Agent.

    Science.gov (United States)

    Babič, Andrej; Vorobiev, Vassily; Xayaphoummine, Céline; Lapicorey, Gaëlle; Chauvin, Anne-Sophie; Helm, Lothar; Allémann, Eric

    2018-01-26

    Gadolinium-loaded nanomicelles show promise as future magnetic resonance imaging (MRI) contrast agents (CAs). Their increased size and high gadolinium (Gd) loading gives them an edge in proton relaxivity over smaller molecular Gd-complexes. Their size and stealth properties are fundamental for their long blood residence time, opening the possibility for use as blood-pool contrast agents. Using l-tyrosine as a three-functional scaffold we synthesized a nanostructure building block 8. The double C18 aliphatic chain on one side, Gd-1,4,7,10-tetraazacyclododecane-1-4-7-triacetic acid (Gd-DO3A) with access to bulk water in the center and 2 kDa PEG on the hydrophilic side gave the amphiphilic properties required for the core-shell nanomicellar architecture. The self-assembly into Gd-loaded monodispersed 10-20 nm nanomicelles occurred spontaneously in water. These nanomicelles (Tyr-MRI) display very high relaxivity at 29 mm -1  s -1 at low field strength and low cytotoxicity. Good contrast enhancement of the blood vessels and the heart together with prolonged circulation time in vivo, makes Tyr-MRI an excellent candidate for a new supramolecular blood-pool MRI CA. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Regional cerebral blood flow and metabolism in patients with transient global amnesia. A study using SPECT and 1H-MRS

    International Nuclear Information System (INIS)

    Ishihara, Tetsuya; Hirata, Koichi; Tatsumoto, Muneto; Yamazaki, Kaoru; Sato, Toshihiko.

    1997-01-01

    In 13 patients with transient global amnesia (TGA), we studied the clinical course and changes over time by means of imaging techniques such as SPECT. MRI, and proton MR spectroscopy ( 1 H-MRS). In the case of SPECT, a cerebral blood flow decrease at the time center of the temporal lobe persisted at least for more than one month. In many patients, no abnormal signs were found on MRI. Despite the presence of intracranial impairment of energy metabolism, no evidence of cerebral ischemia was obtained using 1 H-MRS at the acute and subacute stages. There were thus discrepancies between the symptoms and the findings of SPECT as well as the findings of 1 H-MRS. These data suggest that TGA may not necessarily be caused by cerebra1 ischemia. (author)

  17. Phase analysis of gated blood pool SPECT for multiple stress testing assessments of ventricular mechanical dyssynchrony in a tachycardia-induced dilated cardiomyopathy canine model.

    Science.gov (United States)

    Salimian, Samaneh; Thibault, Bernard; Finnerty, Vincent; Grégoire, Jean; Harel, François

    2017-02-01

    Stress-induced dyssynchrony has been shown to be independently correlated with clinical outcomes in patients with dilated cardiomyopathy (DCM) and narrow QRS complexes. However, the extent to which stress levels affect inter- and intraventricular dyssynchrony parameters remains unknown. Ten large dogs were submitted to tachycardia-induced DCM by pacing the right ventricular apex for 3-4 weeks to reach a target ejection fraction (EF) of 35% or less. Stress was then induced in DCM dogs by administering intravenous dobutamine up to a maximum of 20 μg·kg -1 ·min -1 . Hemodynamic and ventricular dyssynchrony data were analyzed by left ventricular (LV) pressure measurements and gated blood pool SPECT (GBPS) imaging. In order to assess mechanical dyssynchrony in DCM subjects and compare it with that of 8 normal counterparts, we extracted the following data: count-based indices of LV contraction homogeneity index (CHI), entropy and phase standard deviation, and interventricular dyssynchrony index. A significant LV intraventricular dyssynchrony (CHI: 96.4 ± 1.3% in control vs 78.6% ± 10.9% in DCM subjects) resulted in an intense LV dysfunction in DCM subjects (EF: 49.5% ± 8.4% in control vs 22.6% ± 6.0% in DCM), compared to control subjects. However, interventricular dyssynchrony did not vary significantly between the two groups. Under stress, DCM subjects showed a significant improvement in ventricular functional parameters at each level (EF: 22.6% ± 6.0% at rest vs 48.1% ± 5.8% at maximum stress). All intraventricular dyssynchrony indices showed a significant increase in magnitude of synchrony from baseline to stress levels of greater than or equal to 5 μg·kg -1 ·min -1 dobutamine. There were individual differences in the magnitude and pattern of change in interventricular dyssynchrony during the various levels of stress. Based on GBPS analyses, different levels of functional stress, even in close intervals, can have a significant impact on

  18. ECG-gated blood pool tomography in the determination of left ventricular volume, ejection fraction, and wall motion

    International Nuclear Information System (INIS)

    Underwood, S.R.; Ell, P.J.; Jarritt, P.H.; Emanuel, R.W.; Swanton, R.H.

    1984-01-01

    ECG-gated blood pool tomography promises to provide a ''gold standard'' for noninvasive measurement of left ventricular volume, ejection fraction, and wall motion. This study compares these measurements with those from planar radionuclide imaging and contrast ventriculography. End diastolic and end systolic blood pool images were acquired tomographically using an IGE400A rotating gamma camera and Star computer, and slices were reconstructed orthogonal to the long axis of the heart. Left ventricular volume was determined by summing the areas of the slices, and wall motion was determined by comparison of end diastolic and end systolic contours. In phantom experiments this provided an accurate measurement of volume (r=0.98). In 32 subjects who were either normal or who had coronary artery disease left ventricular volume (r=0.83) and ejection fraction (r=0.89) correlated well with those using a counts based planar technique. In 16 of 18 subjects who underwent right anterior oblique X-ray contrast ventriculography, tomographic wall motion agreed for anterior, apical, and inferior walls, but abnormal septal motion which was not apparent by contrast ventriculography, was seen in 12 subjects tomographically. All 12 had disease of the left anterior descending coronary artery and might have been expected to have abnormal septal motion. ECG-gated blood pool tomography can thus determine left ventricular volume and ejection fraction accurately, and provides a global description of wall motion in a way that is not possible from any single planar image

  19. Deficits in Regional Cerebral Blood Flow on Brain SPECT Predict Treatment Resistant Depression.

    Science.gov (United States)

    Amen, Daniel G; Taylor, Derek V; Meysami, Somayeh; Raji, Cyrus A

    2018-03-22

    Depression remains an important risk factor for Alzheimer's disease, yet few neuroimaging biomarkers are available to identify treatment response in depression. To analyze and compare functional perfusion neuroimaging in persons with treatment resistant depression (TRD) compared to those experiencing full remission. A total of 951 subjects from a community psychiatry cohort were scanned with perfusion single photon emission computed tomography (SPECT) of the brain in both resting and task related settings. Of these, 78% experienced either full remission (n = 506) or partial remission (n = 237) and 11% were minimally responsive (n = 103) or non-responsive (11%. n = 106). Severity of depression symptoms were used to define these groups with changes in the Beck Depression Inventory prior to and following treatment. Voxel-based analyses of brain SPECT images from full remission compared to the worsening group was conducted with the statistical parametric mapping software, version 8 (SPM 8). Multiple comparisons were accounted for with a false discovery rate (p <  0.001). Persons with depression that worsened following treatment had reduced cerebral perfusion compared to full remission in the multiple regions including the bilateral frontal lobes, right hippocampus, left precuneus, and cerebellar vermis. Such differences were observed on both resting and concentration SPECT scans. Our findings identify imaging-based biomarkers in persons with depression related to treatment response. These findings have implications in understanding both depression to prognosis and its role as a risk factor for dementia.

  20. Early and delayed pinhole MIBI SPECT in detecting hyperfunctioning parathyroid glands: a comparison with peroperative γ probe.

    Science.gov (United States)

    Gültekin, Salih Sinan; Kir, Metin; Tuğ, Tuğbay; Demirer, Seher; Genç, Yasemin

    2011-10-01

    This study was conducted to evaluate the early and delayed pinhole MIBI single photon emission computed tomography (pSPECT) images in detecting hyperfunctioning parathyroid glands, to make a comparison with peroperative γ probe (GP) findings. Planar, early, and delayed pSPECT scans and skin in-vivo and ex-vivo GP counts were obtained in 22 patients with hyperparathyroidism. All data were analyzed statistically on the basis of localization of the lesions, using the histopathological findings as the gold standard. Histopathological examinations revealed 18 of 44 adenomas, 18 of 44 hyperplasic glands, two of 44 lymph nodules, five of 44 thyroid nodules, and one of 44 normal parathyroid glands. Sensitivity and specificity were found to be 36 and 100% for planar, 69 and 75% for early pSPECT, 86 and 88% for delayed pSPECT scans, and similarly, 78 and 75% on skin, 92 and 75% in-vivo and 83 and 100% ex-vivo GP counts, respectively. For distinction ability of GP counts between three groups of lesions, there was a statistically significant difference among the three groups for ex-vivo GP counts but not between groups of adenomas and hyperplasic lesions for in-vivo GP counts. Early and delayed pSPECT scans play a complementary role on the planar scans. Delayed pSPECT scans and in-vivo GP counts are equally valuable to localize both single and multiple hyperfunctioning parathyroid glands. Ex-vivo GP counts seem to be better for making a distinction among types of lesions.

  1. Clinical Comparison of 99mTc Exametazime and 123I Ioflupane SPECT in Patients with Chronic Mild Traumatic Brain Injury

    OpenAIRE

    Newberg, Andrew B.; Serruya, Mijail; Gepty, Andrew; Intenzo, Charles; Lewis, Todd; Amen, Daniel; Russell, David S.; Wintering, Nancy

    2014-01-01

    BACKGROUND: This study evaluated the clinical interpretations of single photon emission computed tomography (SPECT) using a cerebral blood flow and a dopamine transporter tracer in patients with chronic mild traumatic brain injury (TBI). The goal was to determine how these two different scan might be used and compared to each other in this patient population. METHODS AND FINDINGS: Twenty-five patients with persistent symptoms after a mild TBI underwent SPECT with both (99m)Tc exametazime to m...

  2. Quantitative evaluation of regional cerebral blood flow by visual stimulation in 99mTc-HMPAO brain SPECT

    International Nuclear Information System (INIS)

    Juh, R. H.; Suh, T. S.; Chung, Y. A.

    2002-01-01

    The purpose of this study is to investigate the effects of visual activation and quantitative analysis of regional cerebral blood flow. Visual activation was known to increase regional cerebral blood flow in the visual cortex in occipital lobe. We evaluated that change in the distribution of 99mTc-HMPAO (Hexamethyl propylene amine oxime) to reflect in regional cerebral blood flow. The six volunteers were injected with 925 MBq (mean ages: 26.75 years, n=6, 3men, 3women) underwent MRI and 99mTc- HMPAO SPECT during a rest state with closed eyes and visual stimulated with 8 Hz LED. We delineate the region of interest and calculated the mean count per voxel in each of the fifteen slices to quantitative analysis. The ROI to whole brain ratio and regional index was calculated pixel to pixel subtraction visual non-activation image from visual activation image and constructed brain map using a statistical parameter map (SPM99). The mean regional cerebral blood flow was increased due to visual stimulation. The increase rate of the mean regional cerebral blood flow which of the activation region in primary visual cortex of occipital lobe was 32.50±5.67%. The significant activation sites using a statistical parameter of brain constructed a rendering image and image fusion with SPECT and MRI. Visual activation was revealed significant increase through quantitative analysis in visual cortex. Activation region was certified in Talairach coordinate and primary visual cortex (Ba17),visual association area (Ba18,19) of Brodmann

  3. Quantitative evaluation of regional cerebral blood flow by visual stimulation in 99mTc- HMPAO brain SPECT

    International Nuclear Information System (INIS)

    Juh, Ra Hyeong; Suh, Tae Suk; Kwark, Chul Eun; Choe, Bo Young; Lee, Hyoung Koo; Chung, Yong An; Kim, Sung Hoon; Chung, Soo Kyo

    2002-01-01

    The purpose of this study is to investigate the effects of visual activation and quantitative analysis of regional cerebral blood flow. Visual activation was known to increase regional cerebral blood flow in the visual cortex in occipital lobe. We evaluated that change in the distribution of '9 9m Tc-HMPAO (Hexamethyl propylene amine oxime) to reflect in regional cerebral blood flow. The six volunteers were injected with 925 MBq (mean ages: 26.75 years, n=6, 3men, 3women) underwent MRI and 99m Tc-HMPAO SPECT during a rest state with closed eyes and visual stimulated with 8 Hz LED. We delineate the region of interest and calculated the mean count per voxel in each of the fifteen slices to quantitative analysis. The ROI to whole brain ratio and regional index was calculated pixel to pixel subtraction visual non-activation image from visual activation image and constructed brain map using a statistical parameter map(SPM99). The mean regional cerebral blood flow was increased due to visual stimulation. The increase rate of the mean regional cerebral blood flow which of the activation region in primary visual cortex of occipital lobe was 32.50±5.67%. The significant activation sites using a statistical parameter of brain constructed a rendering image and image fusion with SPECT and MRI. Visual activation was revealed significant increase through quantitative analysis in visual cortex. Activation region was certified in Talairach coordinate and primary visual cortex (Ba17),visual association area (Ba18,19) of Brodmann

  4. Application of blood-pool agents in visualization of peripheral vessels

    International Nuclear Information System (INIS)

    Giovagnoni, A.; Catalano, C.

    2007-01-01

    Effective arterial imaging is essential in patients with peripheral arterial disease (PAD) in whom a revascularization procedure is planned. Digital subtraction angiography (DSA) has traditionally been regarded as the gold standard for imaging in peripheral arterial disease, but this technique is subject to certain limitations, such as the risks of adverse reactions associated with arterial catheterization and iodinated contrast agents. Contrast-enhanced magnetic resonance angiography is now recommended as an effective and useful imaging technique in peripheral arterial disease, since it offers high enhanced contrast between blood and stationary tissue and fast acquisition times. However, extracellular gadolinium contrast agents rapidly diffuse into the interstitial spaces, and thus are suitable only for first-pass imaging. This limitation can be overcome by the use of blood-pool (intravascular) contrast agents, such as gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany), which are retained within the blood vessels and hence facilitate both first-pass and steady-state imaging with high spatial resolution. Blood-pool agents, therefore, offer improved imaging, particularly of distal vessels, compared with extracellular contrast agents. Examples of first-pass and steady-state imaging with gadofosveset are presented. (orig.)

  5. Comparison of two different segmentation methods on planar lung perfusion scan with reference to quantitative value on SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Min Seok; Kang, Yeon Koo; Ha, Seung Gyun [Dept. of Nuclear Medicine, Seoul National University Hospital, Seoul (Korea, Republic of); and others

    2017-06-15

    Until now, there was no single standardized regional segmentation method of planar lung perfusion scan. We compared planar scan based two segmentation methods, which are frequently used in the Society of Nuclear Medicine, with reference to the lung perfusion single photon emission computed tomography (SPECT)/computed tomography (CT) derived values in lung cancer patients. Fifty-five lung cancer patients (male:female, 37:18; age, 67.8 ± 10.7 years) were evaluated. The patients underwent planar scan and SPECT/CT after injection of technetium-99 m macroaggregated albumin (Tc-99 m-MAA). The % uptake and predicted postoperative percentage forced expiratory volume in 1 s (ppoFEV1%) derived from both posterior oblique (PO) and anterior posterior (AP) methods were compared with SPECT/CT derived parameters. Concordance analysis, paired comparison, reproducibility analysis and spearman correlation analysis were conducted. The % uptake derived from PO method showed higher concordance with SPECT/CT derived % uptake in every lobe compared to AP method. Both methods showed significantly different lobar distribution of % uptake compared to SPECT/CT. For the target region, ppoFEV1% measured from PO method showed higher concordance with SPECT/CT, but lower reproducibility compared to AP method. Preliminary data revealed that every method significantly correlated with actual postoperative FEV1%, with SPECT/CT showing the best correlation. The PO method derived values showed better concordance with SPECT/CT compared to the AP method. Both PO and AP methods showed significantly different lobar distribution compared to SPECT/CT. In clinical practice such difference according to different methods and lobes should be considered for more accurate postoperative lung function prediction.

  6. Regional cerebral blood flow and metabolism in patients with transient global amnesia. A study using SPECT and {sup 1}H-MRS

    Energy Technology Data Exchange (ETDEWEB)

    Ishihara, Tetsuya; Hirata, Koichi; Tatsumoto, Muneto; Yamazaki, Kaoru [Dokkyo Univ., Tochigi (Japan). School of Medicine; Sato, Toshihiko

    1997-06-01

    In 13 patients with transient global amnesia (TGA), we studied the clinical course and changes over time by means of imaging techniques such as SPECT. MRI, and proton MR spectroscopy ({sup 1}H-MRS). In the case of SPECT, a cerebral blood flow decrease at the time center of the temporal lobe persisted at least for more than one month. In many patients, no abnormal signs were found on MRI. Despite the presence of intracranial impairment of energy metabolism, no evidence of cerebral ischemia was obtained using {sup 1}H-MRS at the acute and subacute stages. There were thus discrepancies between the symptoms and the findings of SPECT as well as the findings of {sup 1}H-MRS. These data suggest that TGA may not necessarily be caused by cerebra1 ischemia. (author)

  7. High-resolution SPECT for small-animal imaging

    International Nuclear Information System (INIS)

    Qi Yujin

    2006-01-01

    This article presents a brief overview of the development of high-resolution SPECT for small-animal imaging. A pinhole collimator has been used for high-resolution animal SPECT to provide better spatial resolution and detection efficiency in comparison with a parallel-hole collimator. The theory of imaging characteristics of the pinhole collimator is presented and the designs of the pinhole aperture are discussed. The detector technologies used for the development of small-animal SPECT and the recent advances are presented. The evolving trend of small-animal SPECT is toward a multi-pinhole and a multi-detector system to obtain a high resolution and also a high detection efficiency. (authors)

  8. Assessment of sistemic ventricle function in corrected transposition of great arteries with Gated SPECT: comparison with radionuclide ventriculography

    International Nuclear Information System (INIS)

    Alexanderson, E.; Espinola, N.; Duenas, D.; Fermon, S.; Acevedo, C.; Martinez, C.

    2002-01-01

    Corrected trasposition of great arteries is a uncommon congenital heart disease where the right ventricle works as the sistemic one. QGS Gated SPECT program was designed to recognize the contours of left ventricle being a good method to evaluate left ventricle ejection fraction. The purpose of this study was to evaluate the right ventricle ejection fraction (RVEF) by gated SPECT using Tc-99mSestaMIBI in comparison with radionuclide ventriculography (RVG) in patients with corrected trasposition of great arteries. Methods: We performed gated SPECT and radionuclide ventriculography within 15 days of each other in 7 adults consecutive patients with the diagnosis of corrected trasposition of great arteries (5 men, 2 women; mean age 47 y). Gated tomographic data, including ventricular volumes and ejection fraction, were processed using QGS automatic algorithm, whereas equilibrium radionuclide ventriculography used standard techniques. Results: We found a good correlation between right ventricle ejection fraction obtained with Gated SPECT compared with equilibrium radionuclide ventriculography. The mean of the RVEF with Gated SPECT was 41.2% compared with 44.2% of RVEF with equilibrium radionuclide ventriculography. Both methods recognized abnormal RVEF in 5 patients ( 50%) with Gated SPECT and abnormal with RVG meanwhile another patient had normal RVEF with RVG and abnormal with Gated SPECT. Conclusion: Quantitative gated tomography, using Tc 99mSestaMIBI, has a good correlation with radionuclide ventriculography for the assessment of right ventricle ejection fraction in patients with corrected trasposition of great arteries. These results support the clinical use of this technique among these patients

  9. Advances in regional cerebral blood flow measurement and patho-physiological analysis by SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Odano, Ikuo (Niigata Univ. (Japan). School of Medicine)

    1994-04-01

    Recently, two kinds of radiopharmaceuticals have been developed to represent the biodistribution of regional blood flow, which are N-isopropyl-p-[[sup 123]I]iodoamphetamine (IMP) and [sup 99m]Tc-hexamethylpropylene-amine-oxime (HMPAO). The charachteristics, clinical usage and imitation of these two radiolabeled agents are discussed. The advantage of [sup 123]I-IMP is that it has high first-pass extraction and long retention in brain tissue, hence it can be used to measure the absolute values of regional cerebral blood flow (rCBF). When the kinetics of [sup 123]I-IMP is assumed to be freely diffusible in the brain, its behavior is considered by 2-compartment model, especially which is assumed by the microsphere model in the early period after the i.v. injection of [sup 123]I-IMP. Comparing the rCBF measured by [sup 123]I-IMP with that by [sup 133]Xe inhalation SPECT method, we have to consider PaCO[sub 2] when both SPECT studies are performed, because PaCO[sub 2] is one of the big factors which make effects on the alteration of rCBF. [sup 123]I-IMP has an interesting character of the redistribution phenomenon which represrent the degree of ischemia in the cerebrovascular diseases. Distribution volume an important datum obtained by the SPECT study with [sup 123]I-IMP, which represent the degree of retention, i.e. binding potential of [sup 123]I-IMP in the brain tissue. I introduced the usage of the distribution volume of [sup 123]I-IMP, which was constructed in the rate constant square method, in the differential diagnosis of Parkinson's disease and progressive supranuclear palsy (PSP). The clinical usage of [sup 99m] Tc-HMPAT was mentioned, the advantage of which is the rapid fixation in the brain tissue and the distribution does not change for long time after the i.v. injection. Hence [sup 99m]Tc-HMPAO is used for the diagnosis of epileptic foci and certain loading tests such as balloon occlusion test, postural test and acetazolamide loading test. (author).

  10. Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology

    Science.gov (United States)

    Erlandsson, Kjell; Kacperski, Krzysztof; van Gramberg, Dean; Hutton, Brian F.

    2009-05-01

    D-SPECT (Spectrum Dynamics, Israel) is a novel SPECT system for cardiac perfusion studies. Based on CZT detectors, region-centric scanning, high-sensitivity collimators and resolution recovery, it offers potential advantages over conventional systems. A series of measurements were made on a β-version D-SPECT system in order to evaluate its performance in terms of energy resolution, scatter fraction, sensitivity, count rate capability and resolution. Corresponding measurements were also done on a conventional SPECT system (CS) for comparison. The energy resolution of the D-SPECT system at 140 keV was 5.5% (CS: 9.25%), the scatter fraction 30% (CS: 34%), the planar sensitivity 398 s-1 MBq-1 per head (99mTc, 10 cm) (CS: 72 s-1 MBq-1), and the tomographic sensitivity in the heart region was in the range 647-1107 s-1 MBq-1 (CS: 141 s-1 MBq-1). The count rate increased linearly with increasing activity up to 1.44 M s-1. The intrinsic resolution was equal to the pixel size, 2.46 mm (CS: 3.8 mm). The average reconstructed resolution using the standard clinical filter was 12.5 mm (CS: 13.7 mm). The D-SPECT has superior sensitivity to that of a conventional system with similar spatial resolution. It also has excellent energy resolution and count rate characteristics, which should prove useful in dynamic and dual radionuclide studies.

  11. Regional cerebral blood flow in Parkinson's disease measured with N-isopropyl-p-[[sup 123]I]iodoamphetamine (IMP) SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Odano, Ikuo; Nishihara, Mamiko; Hayashi, Hiroko; Higuchi, Shoichi; Sakai, Kunio [Niigata Univ. (Japan). School of Medicine; Ishikawa, Atsushi; Ibayashi, Katsuhiko

    1992-09-01

    N-isopropyl-p-[[sup 123]I]iodoamphetamine (IMP) SPECT studies were performed on 21 patients (13 females; 45-73 yrs) with idiopathic Parkinson's disease (PD) and 10 age-matched normal controls (39-69 yrs). Regional cerebral blood flow (rCBF) was quantitatively measured by the arterial blood sampling method. When compared with normal controls, global CBF, and rCBF in the frontal cortex and in the basal ganglia were reduced 22.1% (p<0.01), 25.0% (p<0.05) and 25.6% (p<0.01), respectively. The reduction of rCBF in the basal ganglia was significantly correlated (p<0.05) with symptoms such as gait disturbance, frozen gait and motor disability score. However, no significant correlation was observed between the severity of dementia and any regional reduction of CBF, including the frontal or parietal cortices. These data show that the severity of dementia in PD may be related to other factors but not with CBF. Quantification of rCBF with [sup 123]I-IMP SPECT imaging is useful for evaluation and follow-up of patients with PD. (author).

  12. Types of traumatic brain injury and regional cerebral blood flow assessed by 99mTc-HMPAO SPECT.

    Science.gov (United States)

    Yamakami, I; Yamaura, A; Isobe, K

    1993-01-01

    To investigate the relationship between focal and diffuse traumatic brain injury (TBI) and regional cerebral blood flow (rCBF), rCBF changes in the first 24 hours post-trauma were studied in 12 severe head trauma patients using single photon emission computed tomography (SPECT) with 99mtechnetium-hexamethyl propyleneamine oxime. Patients were classified as focal or diffuse TBI based on x-ray computed tomographic (X-CT) findings and neurological signs. In six patients with focal damage, SPECT demonstrated 1) perfusion defect (focal severe ischemia) in the brain region larger than the brain contusion by X-CT, 2) hypoperfusion (focal CBF reduction) in the brain region without abnormality by X-CT, and 3) localized hyperperfusion (focal CBF increase) in the surgically decompressed brain after decompressive craniectomy. Focal damage may be associated with a heterogeneous CBF change by causing various focal CBF derangements. In six patients with diffuse damage, SPECT revealed hypoperfusion in only one patient. Diffuse damage may be associated with a homogeneous CBF change by rarely causing focal CBF derangements. The type of TBI, focal or diffuse, determines the type of CBF change, heterogeneous or homogeneous, in the acute severe head trauma patient.

  13. Types of traumatic brain injury and regional cerebral blood flow assessed by 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Yamakami, Iwao; Yamaura, Akira; Isobe, Katsumi

    1993-01-01

    To investigate the relationship between focal and diffuse traumatic brain injury (TBI) and regional cerebral blood flow (rCBF), rCBF changes in the first 24 hours post-trauma were studied in 12 severe head trauma patients using single photon emission computed tomography (SPECT) with 99m technetium-hexamethyl propyleneamine oxime (HMPAO). Patients were classified as focal or diffuse TBI based on x-ray computed tomographic (X-CT) findings and neurological signs. In six patients with focal damage, SPECT demonstrated: 1) perfusion defect (focal severe ischemia) in the brain region larger than the brain contusion by X-CT, 2) hypoperfusion (focal CBF reduction) in the brain region without abnormality by X-CT, and 3) localized hyperperfusion (focal CBF increase) in the surgically decompressed brain after decompressive craniectomy. Focal damage may be associated with a heterogeneous CBF change by causing various focal CBF derangements. In six patients with diffuse damage, SPECT revealed hypoperfusion in only one patient. Diffuse damage may be associated with a homogeneous CBF change by rarely causing focal CBF derangements. The type of TBI, focal or diffuse, determines the type of CBF change, heterogeneous or homogeneous, in the acute severe head trauma patient. (author)

  14. Radionuclide cisternography: SPECT and 3D-rendering

    International Nuclear Information System (INIS)

    Henkes, H.; Huber, G.; Piepgras, U.; Hierholzer, J.; Cordes, M.

    1991-01-01

    Radionuclide cisternography is indicated in the clinical work-up for hydrocephalus, when searching for CSF leaks, and when testing whether or not intracranial cystic lesions are communicating with the adjacent subarachnoid space. This paper demonstrates the feasibility and diagnostic value of SPECT and subsequent 3D surface rendering in addition to conventional rectilinear CSF imaging in eight patients. Planar images allowed the evaluation of CSF circulation and the detection of CSF fistula. They were advantageous in examinations 48 h after application of 111 In-DTPA. SPECT scans, generated 4-24 h after tracer application, were superior in the delineation of basal cisterns, especially in early scans; this was helpful in patients with pooling due to CSF fistula and in cystic lesions near the skull base. A major drawback was the limited image quality of delayed scans, when the SPECT data were degraded by a low count rate. 3D surface rendering was easily feasible from SPECT data and yielded high quality images. The presentation of the spatial distribution of nuclide-contaminated CSF proved especially helpful in the area of the basal cisterns. (orig.) [de

  15. Comparison of MRI, CT, TCD and SPECT in patients with spongiform leukoencephalopathy after inhaling heroin vapor

    International Nuclear Information System (INIS)

    Wang Qun; Lu Bingxun; Yuan Huijuan

    2002-01-01

    Objective: To compare the characteristics of MRI, CT, single photon emission computed tomography (SPECT) and transcranial Doppler sonography (TCD) in patients with spongiform leukoencephalopathy after inhaling heroin vapor. Methods: Seventeen patients were investigated. MRI or CT was scanned in 17 patients, SPECT in 9 patients' and TCD in 11 patients. Results: MRI or CT: Brain MRI and CT revealed extensive symmetric white matter involvement of bilateral cerebral and cerebellar hemispheres and the brainstem. The lesions, which showed no contrast enhancement, were hypodense on CT and hypointense on T 1 -weighted and hyperintense on T 2 -weighted MRI. SPECT: The regional cerebral blood flows (rCBF) of white matter involvement on bilateral cerebral and cerebellar hemispheres was reduced obviously. The rCBF of temporal lobes, parietal lobes, occipital lobes, cerebellar hemispheres, and basal ganglion was reduced in varying degrees. TCD: The systolic peak became sharpened, and end-diastolic flow velocity and mean flow velocity were reduced obviously and pulsatile index was increased markedly in patients with spongiform leukoencephalopathy after inhaling heroin vapor. Conclusion: The characteristic manifestations of MRI and CT imaging may be regarded as the main foundation of diagnosing spongiform leukoencephalopathy after inhaling heroin vapor; SPECT and TCD can help comprehend the changes of hemodynamics of cerebral vessels and the degree of cerebral ischemia in patients with spongiform leukoencephalopathy after inhaling heroin vapor

  16. {sup 99m}Tc-ECD brain perfusion SPECT in hyperalgesic fibromyalgia

    Energy Technology Data Exchange (ETDEWEB)

    Guedj, Eric; Taieb, David; Cammilleri, Serge; Lussato, David; Laforte, Catherine de; Mundler, Olivier [Assistance Publique des Hopitaux de Marseille, Centre Hospitalo-Universitaire de la Timone, Service Central de Biophysique et de Medecine Nucleaire, Marseille Cedex 05 (France); Niboyet, Jean [Clinique La Phoceanne, Unite d' Etude et de Traitement de la Douleur, Marseille (France)

    2007-01-15

    Neuro-imaging studies with {sup 99m}Tc-HMPAO SPECT in fibromyalgia (FM) patients have reported only limited subcortical hypoperfusion. {sup 99m}Tc-ECD SPECT is known to provide better evaluation of areas of high cerebral blood flow and regional metabolic rate. We evaluated a homogeneous group of hyperalgesic patients with FM using {sup 99m}Tc-ECD SPECT. The aim of this study was to investigate brain processing associated with spontaneous pain in FM patients. Eighteen hyperalgesic FM women (mean age 49 years, range 25-63 years; American College of Rheumatology criteria) and ten healthy women matched for age were enrolled in the study. A voxel-by-voxel group analysis was performed using SPM2 (p<0.05, corrected for multiple comparisons). Visual Analogue Scale score for pain was 82{+-}4 at the time of the SPECT study. Compared with control subjects, we observed individual brain SPECT abnormalities in FM patients, confirmed by SPM2 analysis, with hyperperfusion of the somatosensory cortex and hypoperfusion of the frontal, cingulate, medial temporal and cerebellar cortices. In the present study, performed without noxious stimuli in hyperalgesic FM patients, we found significant hyperperfusion in regions of the brain known to be involved in the sensory dimension of pain processing and significant hypoperfusion in areas assumed to be associated with the affective-attentional dimension. As current pharmacological and non-pharmacological therapies act differently on the two components of pain, we hypothesise that SPECT could be a valuable and readily available tool to guide individual therapeutic strategy and provide objective follow-up of pain processing recovery under treatment. (orig.)

  17. Effects of typical antipsychotic, haloperidol on regional cerebral blood flow in drug-naive schizophrenic patients-study with 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Kamoya, Masatoshi

    2001-01-01

    For the purpose of examining antipsychotic action of haloperidol (HPD), effects of chronic perioral administration of HPD 4.5 mg/day on regional cerebral blood flow (rCBF) with 99mTc-HMPAO SPECT were investigated in 12 drug-naive schizophrenic patients with acute hallucinatory and delusional state. Further, the SPECT examinations were performed on 20 normal adult volunteers to investigate differences in rCBFs between schizophrenics and the normal subjects. Results are itemized as follows. The rCBF values were significantly increased in the bilateral superior and middle frontal, cingulate, middle temporal, pre-and post-central gyri, the left superior temporal gyrus, the bilateral inferior parietal lobule, and the bilateral hippocampal and thalamic cortices in comparison between normal subjects and before the HPD dose in schizophrenics. However, the rCBF values after the HPD dose showed significant increases only in the bilateral pre-and post-central gyri in comparison with the normal subjects. The rCBF values were significantly decreased in the bilateral superior, middle and inferior frontal, superior and middle temporal gyri, and the left insular gyrus after the HPD dose in comparison with before the HPD dose. The psychiatric assessment with PANSS showed an improvement of positive symptoms consisting of auditory hallucination and delusions after the HPD dose. Statistical analyses on relationships between the rCBF values and PANSS scores before and after the HPD dose showed positive correlations between the right inferior frontal gyrus and auditory hallucination or positive symptoms, between the right superior temporal gyrus, left thalamus and delusions, and between the left thalamus, insular gyrus and negative symptoms. These results suggest that acute drug-naive schizophrenic patients have widespread cortico-subcortical energic hypermetabolism and HPD reduces the hypermetabolism, leading to whole normalized brain metabolism, in particular with the larger region

  18. Effects of typical antipsychotic, haloperidol on regional cerebral blood flow in drug-naive schizophrenic patients-study with 99mTc-HMPAO SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kamoya, Masatoshi [Kanazawa Medical Univ., Ishikawa (Japan)

    2001-03-01

    For the purpose of examining antipsychotic action of haloperidol (HPD), effects of chronic perioral administration of HPD 4.5 mg/day on regional cerebral blood flow (rCBF) with 99mTc-HMPAO SPECT were investigated in 12 drug-naive schizophrenic patients with acute hallucinatory and delusional state. Further, the SPECT examinations were performed on 20 normal adult volunteers to investigate differences in rCBFs between schizophrenics and the normal subjects. Results are itemized as follows. The rCBF values were significantly increased in the bilateral superior and middle frontal, cingulate, middle temporal, pre-and post-central gyri, the left superior temporal gyrus, the bilateral inferior parietal lobule, and the bilateral hippocampal and thalamic cortices in comparison between normal subjects and before the HPD dose in schizophrenics. However, the rCBF values after the HPD dose showed significant increases only in the bilateral pre-and post-central gyri in comparison with the normal subjects. The rCBF values were significantly decreased in the bilateral superior, middle and inferior frontal, superior and middle temporal gyri, and the left insular gyrus after the HPD dose in comparison with before the HPD dose. The psychiatric assessment with PANSS showed an improvement of positive symptoms consisting of auditory hallucination and delusions after the HPD dose. Statistical analyses on relationships between the rCBF values and PANSS scores before and after the HPD dose showed positive correlations between the right inferior frontal gyrus and auditory hallucination or positive symptoms, between the right superior temporal gyrus, left thalamus and delusions, and between the left thalamus, insular gyrus and negative symptoms. These results suggest that acute drug-naive schizophrenic patients have widespread cortico-subcortical energic hypermetabolism and HPD reduces the hypermetabolism, leading to whole normalized brain metabolism, in particular with the larger region

  19. Estimation of the volume and percent uptake of the liver and spleen by SPECT

    International Nuclear Information System (INIS)

    Yamagata, Atushi

    1988-01-01

    The volume and percent uptake of the liver and spleen were estimated with single photon emission computed tomography (SPECT) using 99m Tc-phytate. Clinical usefulness of these parameters was evaluated by comparison with other liver function tests in 87 patients including 25 normal controls, 24 liver cirrhosis and 16 other chronic liver diseases. SPECT images were obtained by Maxi Camera 400T. Cut-off level for reconstruction of images and relationship between counts and activity (mCi) were obtained from phantom studies. Volumes estimated using SPECT and computed tomography were compared in 16 patients. Results obtained were as follows. 1) Optimal cut-off level for measurement of volumes for the liver was 37 % and for the spleen was 42 %. 2) Correlation between organ volumes estimated with CT and SPECT was good (r = 0.92 for the liver and r = 0.96 for the spleen), although volumes measured with SPECT were larger than those with CT. 3) Significant differences of percent uptake were observed between normal controls and liver cirrhosis. 4) Better correlation between spleen volumes and uptake was recognized in cases without liver cirrhosis than in cases with liver cirrhosis. The spleen uptake in liver cirrhosis was higher than those in others in comparison with the volume. 5) The liver/spleen ratio of 99m Tc-phytae uptake could most clearly differentiate liver cirrhosis from others. 6) Negative correlation was observed between liver volume or uptake and ICG (R 15 ). Estimation of volume and uptake of the liver and spleen could be a useful procedure to assess liver function, probably related with effective hepatic blood flow in liver cirrhosis. (author)

  20. Quantitative cerebral blood flow assessment in senile dementia of Alzheimer type and multi-infarct dementia using sup 123 I-IMP SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Arai, Hisayuki; Hanyu, Haruo; Kobayashi, Yasutaka; Uno, Masanobu; Hatano, Nobuyoshi; Shin, Kouichi; Katsunuma, Hideyo; Suzuki, Takanari; Murayama, Hiroyasu [Tokyo Medical Coll. (Japan)

    1990-06-01

    In order to compare senile dementia of Alzheimer type (SDAT) with multi-infarct dementia (MID) from the standpoint of cerebral blood flow, a study was carried out by using single photon emission CT (SPECT) with N-isopropyl-p-({sup 123}I) iodoamphetamine on 14 healthy aged subjects, 12 patients with SDAT, 8 patients with MID and 7 patients with multiple infarction (MI). The diagnosis of SDAT, MID and MI was based on a clinical history, X-ray CT findings and Hachinski's ischemic score. Venous blood sampling method of Matsuda et al. was used as quantitative cerebral blood flow measurements. The mean cerebral blood flow (mCBF) values in controls was 52.1{plus minus}5.5 ml/100 g/min, while the corresponding values in SDAT, MI and MID were 36.9{plus minus}5.0, 41.0{plus minus}6.2, and 37.7{plus minus}4.3 ml/100 g/min. The regional cerebral blood flow (rCBF) was decreased mainly at bilateral frontal lobes in MID and at temporal and parietal lobes in SDAT. Verbal intelligence score (Hasegawa's dementia score) correlated with rCBF at frontal lobes in MID. These findings suggest that quantitative rCBF measurement by {sup 123}I-IMP SPECT is useful to differentiate MID from SDAT. (author).

  1. Quantitative evaluation of regional cerebral blood flow by visual stimulation in {sup 99m}Tc- HMPAO brain SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Juh, Ra Hyeong; Suh, Tae Suk; Kwark, Chul Eun; Choe, Bo Young; Lee, Hyoung Koo; Chung, Yong An; Kim, Sung Hoon; Chung, Soo Kyo [College of Medicine, The Catholic Univ. of Seoul, Seoul (Korea, Republic of)

    2002-06-01

    The purpose of this study is to investigate the effects of visual activation and quantitative analysis of regional cerebral blood flow. Visual activation was known to increase regional cerebral blood flow in the visual cortex in occipital lobe. We evaluated that change in the distribution of '9{sup 9m}Tc-HMPAO (Hexamethyl propylene amine oxime) to reflect in regional cerebral blood flow. The six volunteers were injected with 925 MBq (mean ages: 26.75 years, n=6, 3men, 3women) underwent MRI and {sup 99m}Tc-HMPAO SPECT during a rest state with closed eyes and visual stimulated with 8 Hz LED. We delineate the region of interest and calculated the mean count per voxel in each of the fifteen slices to quantitative analysis. The ROI to whole brain ratio and regional index was calculated pixel to pixel subtraction visual non-activation image from visual activation image and constructed brain map using a statistical parameter map(SPM99). The mean regional cerebral blood flow was increased due to visual stimulation. The increase rate of the mean regional cerebral blood flow which of the activation region in primary visual cortex of occipital lobe was 32.50{+-}5.67%. The significant activation sites using a statistical parameter of brain constructed a rendering image and image fusion with SPECT and MRI. Visual activation was revealed significant increase through quantitative analysis in visual cortex. Activation region was certified in Talairach coordinate and primary visual cortex (Ba17),visual association area (Ba18,19) of Brodmann.

  2. Quantitative evaluation of regional cerebral blood flow by visual stimulation in {sup 99m}Tc-HMPAO brain SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Juh, R. H.; Suh, T. S.; Chung, Y. A. [The Catholic Univ., of Korea, Seoul (Korea, Republic of)

    2002-07-01

    The purpose of this study is to investigate the effects of visual activation and quantitative analysis of regional cerebral blood flow. Visual activation was known to increase regional cerebral blood flow in the visual cortex in occipital lobe. We evaluated that change in the distribution of 99mTc-HMPAO (Hexamethyl propylene amine oxime) to reflect in regional cerebral blood flow. The six volunteers were injected with 925 MBq (mean ages: 26.75 years, n=6, 3men, 3women) underwent MRI and 99mTc- HMPAO SPECT during a rest state with closed eyes and visual stimulated with 8 Hz LED. We delineate the region of interest and calculated the mean count per voxel in each of the fifteen slices to quantitative analysis. The ROI to whole brain ratio and regional index was calculated pixel to pixel subtraction visual non-activation image from visual activation image and constructed brain map using a statistical parameter map (SPM99). The mean regional cerebral blood flow was increased due to visual stimulation. The increase rate of the mean regional cerebral blood flow which of the activation region in primary visual cortex of occipital lobe was 32.50{+-}5.67%. The significant activation sites using a statistical parameter of brain constructed a rendering image and image fusion with SPECT and MRI. Visual activation was revealed significant increase through quantitative analysis in visual cortex. Activation region was certified in Talairach coordinate and primary visual cortex (Ba17),visual association area (Ba18,19) of Brodmann.

  3. SPECT I-123 iodoamphetamine brain imaging

    International Nuclear Information System (INIS)

    Tikofsky, R.S.; Liebman, A.; Hellman, R.S.; Collier, B.D.; Voslar, A.M.

    1988-01-01

    SPECT/IMP studies of 100 patients with a presumptive diagnosis of dementia were performed with a rotating gamma camera 15-20 minutes after intravenous injection of 3.5 mCi of IMP. Of these studies, 43 were interpreted as normal for age; 28 demonstrated decreased but not absent activity bilaterally in posterior parietal/occipital regions (consistent with Alzheimer-type dementia); 28 showed unilateral abnormalities in regional cerebral blood flow consistent with cerebrovascular disease; and one had mixed findings. Based on SPECT/IMP results, further diagnostic testing and/or management would be altered for 72% of patients, suggesting that SPECT/IMP provides valuable data, not available on clinical examination, to guide the evaluation and management of demented patients

  4. HM-PAO-SPECT in complicated migraine. Case report

    Energy Technology Data Exchange (ETDEWEB)

    Gruenwald, F.; Ruhlmann, J.; Biersack, H.J.; Durwen, H.; Penin, H.

    1988-10-01

    Three HM-PAO-SPECT investigations have been performed in a female patient with a complicated migraine. 2.5 hours after an attack with right-sided numbness and atonic hemiparesis, at the left side a reduced blood flow was seen parietotemporally and in the subcortical structures. The cerebellum showed crossed diaschisis. During a symptom-free interval the SPECT showed a slightly increased parietotemporal blood blow and a reduced right temporooccipital blood flow. During a seizure with left-sided facial spasm, unsystematic clonic movements in all extremities and a following left-sided hemiparesis, the uptake in the visual cortex was increased by 60%. In the right frontotemporal and left temporal region a slightly increased accumulation was found.

  5. A new prognostic index - leucocyte infiltration - in human cerebral infarcts by 99Tcm-HMPAO-labelled white blood cell brain SPECT

    International Nuclear Information System (INIS)

    Kao, C.H.; Wang, P.Y.; Wang, Y.L.; Chang, L.; Wang, S.J.; Yeh, S.H.

    1991-01-01

    Twenty-six patients with acute cerebral infarction were imaged by 99 Tc m -hexamethylpropylene-amine oxime (HMPAO)-labelled white blood cell brain (Tc-WBC) single photon emission computed tomography (SPECT). The regions of interest were equally placed in the whole hemispheres of both sides with summation of all transaxial slices in the Tc-WBC SPECT. The asymmetric indices (AI) were calculated as 200 [|(right -left)|/(right + left)]. Grouping of patients with cerebral infarction was based on activities of daily living (ADL) at outcome. The results showed that the poor outcome patient group had a higher AI of Tc-WBC than that of the other patients (13.0 ± 3.0 S.E.M. versus 5.4 ± 1.0 S.E.M., and P < 0.05 by Wilcoxon rank sum test). In conclusion, the Tc-WBC SPECT may be considered as a new prognostic index to predict patient outcome in human cerebral ischaemic infarctions consistent with newly established ischaemic injury theories. (author)

  6. Reduced dose measurement of absolute myocardial blood flow using dynamic SPECT imaging in a porcine model

    International Nuclear Information System (INIS)

    Timmins, Rachel; Klein, Ran; Petryk, Julia; Marvin, Brian; Kemp, Robert A. de; Ruddy, Terrence D.; Wells, R. Glenn; Wei, Lihui

    2015-01-01

    Purpose: Absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurements provide important additional information over traditional relative perfusion imaging. Recent advances in camera technology have made this possible with single-photon emission tomography (SPECT). Low dose protocols are desirable to reduce the patient radiation risk; however, increased noise may reduce the accuracy of MBF measurements. The authors studied the effect of reducing dose on the accuracy of dynamic SPECT MBF measurements. Methods: Nineteen 30–40 kg pigs were injected with 370 + 1110 MBq of Tc-99m sestamibi or tetrofosmin or 37 + 111 MBq of Tl-201 at rest + stress. Microspheres were injected simultaneously to measure MBF. The pigs were imaged in list-mode for 11 min starting at the time of injection using a Discovery NM 530c camera (GE Healthcare). Each list file was modified so that 3/4, 1/2, 1/4, 1/8, 1/16, and 1/32 of the original counts were included in the projections. Modified projections were reconstructed with CT-based attenuation correction and an energy window-based scatter correction and analyzed with FlowQuant kinetic modeling software using a 1-compartment model. A modified Renkin-Crone extraction function was used to convert the tracer uptake rate K1 to MBF values. The SPECT results were compared to those from microspheres. Results: Correlation between SPECT and microsphere MBF values for the full injected activity was r ≥ 0.75 for all 3 tracers and did not significantly degrade over all count levels. The mean MBF and MFR and the standard errors in the estimates were not significantly worse than the full-count data at 1/4-counts (Tc99m-tracers) and 1/2-counts (Tl-201). Conclusions: Dynamic SPECT measurement of MBF and MFR in pigs can be performed with 1/4 (Tc99m-tracers) or 1/2 (Tl-201) of the standard injected activity without significantly reducing accuracy and precision

  7. Reduced dose measurement of absolute myocardial blood flow using dynamic SPECT imaging in a porcine model

    Energy Technology Data Exchange (ETDEWEB)

    Timmins, Rachel; Klein, Ran; Petryk, Julia; Marvin, Brian; Kemp, Robert A. de; Ruddy, Terrence D.; Wells, R. Glenn, E-mail: gwells@ottawaheart.ca [Division of Cardiology, University of Ottawa Heart Institute, Ottawa, Ontario K1Y4W7 (Canada); Wei, Lihui [Nordion, Inc., Ottawa, Ontario K2K 1X8 (Canada)

    2015-09-15

    Purpose: Absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurements provide important additional information over traditional relative perfusion imaging. Recent advances in camera technology have made this possible with single-photon emission tomography (SPECT). Low dose protocols are desirable to reduce the patient radiation risk; however, increased noise may reduce the accuracy of MBF measurements. The authors studied the effect of reducing dose on the accuracy of dynamic SPECT MBF measurements. Methods: Nineteen 30–40 kg pigs were injected with 370 + 1110 MBq of Tc-99m sestamibi or tetrofosmin or 37 + 111 MBq of Tl-201 at rest + stress. Microspheres were injected simultaneously to measure MBF. The pigs were imaged in list-mode for 11 min starting at the time of injection using a Discovery NM 530c camera (GE Healthcare). Each list file was modified so that 3/4, 1/2, 1/4, 1/8, 1/16, and 1/32 of the original counts were included in the projections. Modified projections were reconstructed with CT-based attenuation correction and an energy window-based scatter correction and analyzed with FlowQuant kinetic modeling software using a 1-compartment model. A modified Renkin-Crone extraction function was used to convert the tracer uptake rate K1 to MBF values. The SPECT results were compared to those from microspheres. Results: Correlation between SPECT and microsphere MBF values for the full injected activity was r ≥ 0.75 for all 3 tracers and did not significantly degrade over all count levels. The mean MBF and MFR and the standard errors in the estimates were not significantly worse than the full-count data at 1/4-counts (Tc99m-tracers) and 1/2-counts (Tl-201). Conclusions: Dynamic SPECT measurement of MBF and MFR in pigs can be performed with 1/4 (Tc99m-tracers) or 1/2 (Tl-201) of the standard injected activity without significantly reducing accuracy and precision.

  8. 99mTc-MDP combined blood pool and bone phase radionuclide imaging in papain-injected carpal joints

    International Nuclear Information System (INIS)

    Metcalf, M.R.; Twardock, A.R.; Sanecki, R.K.

    1985-01-01

    Scintigraphic changes, i.e., increased activity, were induced by 1% papain, dissolved in phosphate-buffered physiologic saline (pH 7.4), injected into one antebrachiocarpal joint in each of eight dogs. Scintigraphic evaluation was by the use of combined blood pool and bone phase scintigraphy of affected and normal carpi over a 28-day period. The qualitative and quantitative scintigraphic appearance in injected carpal joints were very similar in both blood pool and bone phases. The clinical use of combined blood pool and bone phase scintigraphy to diagnose early inflammatory joint changes appears limited

  9. Motor activation SPECT for the neurosurgical diseases. Examination protocol and basic study

    Energy Technology Data Exchange (ETDEWEB)

    Noguchi, Hiroshi; Kawaguchi, Shoichiro; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime [Nara Medical Univ., Kashihara (Japan)

    1999-07-01

    We examined and analyzed the region activated by the unilateral finger opposition task using motor activation single photon emission computed tomography (M-SPECT). M-SPECT studies were carried out on 11 cases, all of whom were normal volunteers (mean age: 49.4 years), none of whom showed any abnormal findings on magnetic resonance images (MRIs) or any neurological abnormalities. The SPECT images for each case were superimposed on the MRIs using Image Fusion Software. The result of the M-SPECT study was expressed as positive or negative. The cases with a marked increase of blood flow in the sensori-motor cortex during the finger opposition task were categorized as positive, and those cases showing no marked increase of blood flow were categorized as negative. Among 11 patients, 10 cases (90.9%) showed positive M-SPECT findings, and the eleventh case showed negative M-SPECT findings. The asymmetry index (AI) was calculated on the sensorio-motor cortex in the SPECT images before and after motor activation, with the 10 cases with positive M-SPECT having an AI before motor activation of 0.99{+-}0.06 (mean{+-}standard deviation) and an AI after motor activation of 1.14{+-}0.07. This change was statistically significant (p<0.05). In the single case categorized as negative, the AI before motor activation was 1.04, and the AI after motor activation was 1.01. There was no significant difference of AI values between the resting and motor activation stages. The positive M-SPECT was seen in 90.9% of the normal volunteer series using a visual inspection method. In these cases, the blood flow in the sensorio-motor cortex significantly increased after application of the finger opposition task using the semi-quantitative method. (author)

  10. Cerebral blood flow and metabolism of the patients with a carotid stenosis evaluated by SPECT and 1H-MRS

    International Nuclear Information System (INIS)

    Uno, Masaaki; Nishi, Kyouko; Shinno, Kiyohito; Nagahiro, Shinji; Ohtsuka, Hideki; Harada, Masafumi

    1998-01-01

    We examined cerebral blood flow (CBF) and metabolic states in patients with a severe carotid stenosis by SPECT and proton MRS ( 1 H-MRS). SPECT using 99m Tc-HMPAO and 1 H-MRS were performed in twenty five patients with over 70% carotid stenosis. Moreover, 10 patients were evaluated by these methods after carotid endarterectomy (CEA). N-acetyl-aspartate (NAA) on the ipsilateral side was reduced in 17 patients (Group A) while NAA of other 8 patients was not reduced (Group B). In Group A, although regional CBF was reduced in only 4 of 17 patients, 11 patients showed decline of cerebral vasoreactivity evaluated by acetazolamide injection. Concentration of NAA and regional CBF showed significant correlations. After CEA, ipsilateral NAA was increased significantly compared to preoperative NAA level. In 6 of 7 patients in Group A, cerebral vasoreactivity also improved postoperatively. These results indicated that ipsilatereal NAA metabolism and cerebral vasoreactivity can be improved after CEA. SPECT and 1 H-MRS were useful to evaluate CBF and metabolism in patients with carotid stenosis. (author)

  11. The use of SPECT in the study of depression

    International Nuclear Information System (INIS)

    Yu Jing; The Second Affiliated Hospital of Dalian Medical Univ., Dalian; Tang Yiyuan

    2007-01-01

    Functional imaging is an effective methods in the study of psychological disturbances. The SPECT imaging methods commonly used in the study of depression are cerebral blood flow imaging, cerebral metabolic imaging and neuroreceptor imaging, which reflect the cerebral blood perfusion, cerebral metabolism, and the distribution and function of neuroreceptors respectively. The techniques in data processing include and statistical parametric mapping. This review summarizes the feature of the imaging and data processing methods, the manifestation of SPECT images in depressive patients, the brain region with abnormal blood flow and the findings in neuroreceptor imaging; analyzes the problems in current reports and prospects future studies. (authors)

  12. Measurement of lung water with SPECT

    International Nuclear Information System (INIS)

    Chu, R.Y.L.; Ficken, V.J.; Ekeh, S.U.; Ryals, C.J.; Allen, E.W.; Basmadjian, G.

    1990-01-01

    This paper investigates the use of iodoantipyrine (IAP) labeled with radioactive iodine (I-123) and single photon emission tomography (SPECT) to measure lung water. I-123 IAP was injected intravenously to six New Zealand White rabbits under anesthesia. After 1 hour, Tc-99m macroaggregates of albumin (MAA) were injected. SPECT imaging was performed in dual-energy mode. After a blood sample was drawn, the animals were sacrificed, and the lungs were removed. Blood samples were assayed for radioactivity. The lungs were weighed, dried, and weighted again to determine water content. The product of area defined by MAA in a tomogram and IAP count rate of central pixels of that region in the corresponding tomogram was taken as the relative amount of IAP in each lung

  13. Contribution of subtraction ictal SPECT coregistered to MRI to epilepsy surgery. A multicenter study

    International Nuclear Information System (INIS)

    Matsuda, Hiroshi; Matsuda, Kazumi; Nakamura, Fumihiro

    2009-01-01

    A multicenter prospective study was performed to assess the additional value of a subtraction ictal single photon emission computed tomography (SPECT) coregistered to MRI (SISCOM) technique to traditional side-by-side comparison of ictal- and interictal SPECT images in epilepsy surgery. One hundred and twenty-three patients with temporal and extratemporal lobe epilepsy who had undergone epilepsy surgery after evaluation of scalp ictal and interictal electroencephalogram (EEG), MRI, and ictal and interictal SPECT scans were followed up in terms of postsurgical outcome for a period of at least 1 year. Three reviewers localized the epileptogenic focus using ictal and interictal SPECT images first by side-by-side comparison and subsequently by SISCOM. Concordance of the localization of the epileptogenic focus by SPECT diagnosis with the surgical site and inter-observer agreement between reviewers was compared between side-by-side comparison and SISCOM. Logistic regression analysis was performed in predicting the surgical outcome with the dependent variable being the achievement of a good postsurgical outcome and the independent variables using the SISCOM, side-by-side comparison of ictal and interictal SPECT images, MRI, and scalp ictal EEG. The SISCOM presented better concordance in extratemporal lobe epilepsy and less concordance in temporal lobe epilepsy than side-by-side comparison. Inter-observer concordance was higher in SISCOM than in side-by-side comparison. Much higher concordance of the epileptogenic focus by SPECT diagnosis with the surgical site was obtained in patients with good surgical outcome than in those with poor surgical outcome. These differences in concordance between good and poor surgical outcomes were greater in SISCOM than in side-by-side comparison. Logistic regression analysis showed the highest odds ratio of 12.391 (95% confidence interval; 3.319, 46.254) by SISCOM evaluation for concordance of the epileptogenic focus with the surgical site

  14. Noise suppressed partial volume correction for cardiac SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Chung; Liu, Chi, E-mail: chi.liu@yale.edu [Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut 06520 (United States); Liu, Hui [Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut 06520 and Key Laboratory of Particle and Radiation Imaging (Tsinghua University), Ministry of Education, Beijing 100084 (China); Grobshtein, Yariv [GE Healthcare, Haifa 3910101 (Israel); Stacy, Mitchel R. [Department of Internal Medicine, Yale University, New Haven, Connecticut 06520 (United States); Sinusas, Albert J. [Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut 06520 and Department of Internal Medicine, Yale University, New Haven, Connecticut 06520 (United States)

    2016-09-15

    Purpose: Partial volume correction (PVC) methods typically improve quantification at the expense of increased image noise and reduced reproducibility. In this study, the authors developed a novel voxel-based PVC method that incorporates anatomical knowledge to improve quantification while suppressing noise for cardiac SPECT/CT imaging. Methods: In the proposed method, the SPECT images were first reconstructed using anatomical-based maximum a posteriori (AMAP) with Bowsher’s prior to penalize noise while preserving boundaries. A sequential voxel-by-voxel PVC approach (Yang’s method) was then applied on the AMAP reconstruction using a template response. This template response was obtained by forward projecting a template derived from a contrast-enhanced CT image, and then reconstructed using AMAP to model the partial volume effects (PVEs) introduced by both the system resolution and the smoothing applied during reconstruction. To evaluate the proposed noise suppressed PVC (NS-PVC), the authors first simulated two types of cardiac SPECT studies: a {sup 99m}Tc-tetrofosmin myocardial perfusion scan and a {sup 99m}Tc-labeled red blood cell (RBC) scan on a dedicated cardiac multiple pinhole SPECT/CT at both high and low count levels. The authors then applied the proposed method on a canine equilibrium blood pool study following injection with {sup 99m}Tc-RBCs at different count levels by rebinning the list-mode data into shorter acquisitions. The proposed method was compared to MLEM reconstruction without PVC, two conventional PVC methods, including Yang’s method and multitarget correction (MTC) applied on the MLEM reconstruction, and AMAP reconstruction without PVC. Results: The results showed that the Yang’s method improved quantification, however, yielded increased noise and reduced reproducibility in the regions with higher activity. MTC corrected for PVE on high count data with amplified noise, although yielded the worst performance among all the methods

  15. Types of traumatic brain injury and regional cerebral blood flow assessed by [sup 99m]Tc-HMPAO SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yamakami, Iwao; Yamaura, Akira; Isobe, Katsumi [Chiba Univ. (Japan). School of Medicine

    1993-01-01

    To investigate the relationship between focal and diffuse traumatic brain injury (TBI) and regional cerebral blood flow (rCBF), rCBF changes in the first 24 hours post-trauma were studied in 12 severe head trauma patients using single photon emission computed tomography (SPECT) with [sup 99m]technetium-hexamethyl propyleneamine oxime (HMPAO). Patients were classified as focal or diffuse TBI based on x-ray computed tomographic (X-CT) findings and neurological signs. In six patients with focal damage, SPECT demonstrated: (1) perfusion defect (focal severe ischemia) in the brain region larger than the brain contusion by X-CT, (2) hypoperfusion (focal CBF reduction) in the brain region without abnormality by X-CT, and (3) localized hyperperfusion (focal CBF increase) in the surgically decompressed brain after decompressive craniectomy. Focal damage may be associated with a heterogeneous CBF change by causing various focal CBF derangements. In six patients with diffuse damage, SPECT revealed hypoperfusion in only one patient. Diffuse damage may be associated with a homogeneous CBF change by rarely causing focal CBF derangements. The type of TBI, focal or diffuse, determines the type of CBF change, heterogeneous or homogeneous, in the acute severe head trauma patient. (author).

  16. Evaluation of reconstruction techniques in regional cerebral blood flow SPECT using trade-off plots: a Monte Carlo study.

    Science.gov (United States)

    Olsson, Anna; Arlig, Asa; Carlsson, Gudrun Alm; Gustafsson, Agnetha

    2007-09-01

    The image quality of single photon emission computed tomography (SPECT) depends on the reconstruction algorithm used. The purpose of the present study was to evaluate parameters in ordered subset expectation maximization (OSEM) and to compare systematically with filtered back-projection (FBP) for reconstruction of regional cerebral blood flow (rCBF) SPECT, incorporating attenuation and scatter correction. The evaluation was based on the trade-off between contrast recovery and statistical noise using different sizes of subsets, number of iterations and filter parameters. Monte Carlo simulated SPECT studies of a digital human brain phantom were used. The contrast recovery was calculated as measured contrast divided by true contrast. Statistical noise in the reconstructed images was calculated as the coefficient of variation in pixel values. A constant contrast level was reached above 195 equivalent maximum likelihood expectation maximization iterations. The choice of subset size was not crucial as long as there were > or = 2 projections per subset. The OSEM reconstruction was found to give 5-14% higher contrast recovery than FBP for all clinically relevant noise levels in rCBF SPECT. The Butterworth filter, power 6, achieved the highest stable contrast recovery level at all clinically relevant noise levels. The cut-off frequency should be chosen according to the noise level accepted in the image. Trade-off plots are shown to be a practical way of deciding the number of iterations and subset size for the OSEM reconstruction and can be used for other examination types in nuclear medicine.

  17. Absolute quantitation of myocardial blood flow with {sup 201}Tl and dynamic SPECT in canine: optimisation and validation of kinetic modelling

    Energy Technology Data Exchange (ETDEWEB)

    Iida, Hidehiro; Kim, Kyeong-Min; Nakazawa, Mayumi; Sohlberg, Antti; Zeniya, Tsutomu; Hayashi, Takuya; Watabe, Hiroshi [National Cardiovascular Center Research Institute, Department of Investigative Radiology, Suita City, Osaka (Japan); Eberl, Stefan [National Cardiovascular Center Research Institute, Department of Investigative Radiology, Suita City, Osaka (Japan); Royal Prince Alfred Hospital, PET and Nuclear Medicine Department, Camperdown, NSW (Australia); Tamura, Yoshikazu [Akita Kumiai General Hospital, Department of Cardiology, Akita City (Japan); Ono, Yukihiko [Akita Research Institute of Brain, Akita City (Japan)

    2008-05-15

    {sup 201}Tl has been extensively used for myocardial perfusion and viability assessment. Unlike {sup 99m}Tc-labelled agents, such as {sup 99m}Tc-sestamibi and {sup 99m}Tc-tetrofosmine, the regional concentration of {sup 201}Tl varies with time. This study is intended to validate a kinetic modelling approach for in vivo quantitative estimation of regional myocardial blood flow (MBF) and volume of distribution of {sup 201}Tl using dynamic SPECT. Dynamic SPECT was carried out on 20 normal canines after the intravenous administration of {sup 201}Tl using a commercial SPECT system. Seven animals were studied at rest, nine during adenosine infusion, and four after beta-blocker administration. Quantitative images were reconstructed with a previously validated technique, employing OS-EM with attenuation-correction, and transmission-dependent convolution subtraction scatter correction. Measured regional time-activity curves in myocardial segments were fitted to two- and three-compartment models. Regional MBF was defined as the influx rate constant (K{sub 1}) with corrections for the partial volume effect, haematocrit and limited first-pass extraction fraction, and was compared with that determined from radio-labelled microspheres experiments. Regional time-activity curves responded well to pharmacological stress. Quantitative MBF values were higher with adenosine and decreased after beta-blocker compared to a resting condition. MBFs obtained with SPECT (MBF{sub SPECT}) correlated well with the MBF values obtained by the radio-labelled microspheres (MBF{sub MS}) (MBF{sub SPECT} = -0.067 + 1.042 x MBF{sub MS}, p < 0.001). The three-compartment model provided better fit than the two-compartment model, but the difference in MBF values between the two methods was small and could be accounted for with a simple linear regression. Absolute quantitation of regional MBF, for a wide physiological flow range, appears to be feasible using {sup 201}Tl and dynamic SPECT. (orig.)

  18. Methods of evaluating SPECT images. The usefulness of the Matsuda`s method by the Patlak plot method in children

    Energy Technology Data Exchange (ETDEWEB)

    Takaishi, Yasuko [Nippon Medical School, Tokyo (Japan); Hashimoto, Kiyoshi; Fujino, Osamu [and others

    1998-11-01

    Single photon emission computed tomography (SPECT) is a tool to study cerebral blood flow (CBF) kinetics. There are three methods of evaluating SPECT images: visual, semi-quantitative (evaluation of the radioactivity ratio of the cerebral region to the cerebellum (R/CE) or to the thalamus (R/TH)) and quantitative (Matsuda`s method by Patlak plot method using {sup 99m}Tc-hexamethylpropylene amine oxime radionuclide angiography). We evaluated SPECT images by the quantitative method in 14 patients with neurological disorders and examined the correlation of the results to those obtained by the semi-quantitative method. There was no significant correlation between the R/CE or R/TH ratio and regional CBF except two regions. The evaluation by the semi-quantitative method may have been inappropriate, probably because the cerebellar or thalamic blood flow was not constant in each case. Evaluation by the quantitative method, on the other hand, seemed to be useful not only for the comparison of CBF among normal subjects, but also in the demonstration of progressive changes of CBF in the same case. The Matsuda`s method by the Patlak plot method is suitable for examination of children, since it dose not require aortic blood sampling. (author)

  19. Benign versus malignant osseous lesions in spine: differentiation by means of bone SPECT/CT fused image

    International Nuclear Information System (INIS)

    Yao Zhiming; Qu Wanying

    2004-01-01

    This study compared the efficiency of SPECT-CT fused image with planar bone scan, bone SPECT and CT in differentiating malignant from benign lesions and detecting metastases to the spine. Methods. Total 144 patients with spinal lesions underwent planar bone scan (WB), single photon tomography (SPECT), CT and SPECT-CT fused image by a SPECT/CT system. The malignant or benign nature of lesions was proved by radiological Methods, histological findings, 6-24 month follow-up, or all of these. The diagnostic results was divided into 4 types, i.e., normal, benign, doubtful malignant and malignant. Results. There were 137 malignant and 252 benign lesions in 144 patients, respectively. The percentages of doubtful malignant diagnosed by WB, SPECT, CT and fused image are 22.6%, 5.1%, 9.5% and 0%, respectively, p < 0.01-0.001, except for the comparison between the percentages of SPECT and CT. Sensitivities in detection of malignant lesions by WB, SPECT, CT and fused image are 75.2%, 94.2%, 96.6% and 99.3%, respectively, P < 0.001, excepting for the comparisons between those of SPECT and CT, and between those of CT and fused image. The sensitivities m detection of benign lesions by WB, SPECT, CT and fused image are, 56.7%, 86.5%, 90.1% and 96.8%, respectively, P < 0.005 - 0.001, excepting for the comparison between those of SPECT and CT. The specificities in detection of maliganant lesions by WB, SPECT, CT and fused image are 70.6%, 88.9%, 97.2% and 97.6%, respectively, P < 0.001, excepting for the comparison between those of CT and fused image. Conclusion. Bone SPECT-CT fused image has highest diagnostic and differentiating diagnostic values in detection of spinal abnormalities over the planar bone scanning and SPECT. The CT by present SPECT/CT system can complement planar bone scanning and SPECT and is clinically valuable in detection of spinal abnormalities. (authors)

  20. Effect of STA-MCA bypass based on the motor activation SPECT

    International Nuclear Information System (INIS)

    Kawaguchi, Shoichiro; Uranishi, Ryunosuke; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime

    1999-01-01

    The effect of STA-MCA bypass for ischemic cerebrovascular diseases (CVDs) on pure motor function using motor activation SPECT was evaluated and analyzed, and this effect with the resting cerebral blood flow and reserved capacity was compared. Motor activation SPECT were carried out on 22 cases with STA-MCA bypass for symptomatic ischemic CVDs. All motors activation SPECT using the finger opposition task on the affected side were performed before bypass, at 1 month, and 3 months after the bypass. Visual inspection was used to determine whether the result of the motor activation SPECT was as negative or positive. The activated region was detected anatomically precisely by superimposing the SPECT on the MRI. Before this study, the same examination was performed on normal controls. In controls, 91% showed the activated area on the sensorimotor cortex after the finger opposition tasks. Before bypass, the resting SPECT revealed reduction of cerebral blood flow (CBF) on the affected side in all cases. All cases also showed a disturbed response to acetazolamide (ACZ). Nine cases were positive in the motor activation SPECT. One month after bypass, the resting CBF increased in 11 cases. Seven showed preoperative positive motor activation. Fifteen cases were positive in the motor activation SPECT. Three months after bypass, 20 cases showed improvement in the resting CBF, and 19 cases were positive in the motor activation SPECT. Ten cases were negative in the preoperative motor activation SPECT. At one month after surgery, ACZ activation SPECT was performed in 12 cases. Five showed improvement of the response to ACZ. At 3 months after surgery, 8 of 12 cases treated with ACZ activation SPECT showed improved response to ACZ. In most of the cases, improved response to ACZ could be seen after response to motor activation improved. STA-MCA bypass is useful not only for resting CBF but also for pure motor function based on motor activation SPECT. (K.H.)

  1. Effect of STA-MCA bypass based on the motor activation SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, Shoichiro; Uranishi, Ryunosuke; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime [Nara Medical Univ., Kashihara (Japan)

    1999-07-01

    The effect of STA-MCA bypass for ischemic cerebrovascular diseases (CVDs) on pure motor function using motor activation SPECT was evaluated and analyzed, and this effect with the resting cerebral blood flow and reserved capacity was compared. Motor activation SPECT were carried out on 22 cases with STA-MCA bypass for symptomatic ischemic CVDs. All motors activation SPECT using the finger opposition task on the affected side were performed before bypass, at 1 month, and 3 months after the bypass. Visual inspection was used to determine whether the result of the motor activation SPECT was as negative or positive. The activated region was detected anatomically precisely by superimposing the SPECT on the MRI. Before this study, the same examination was performed on normal controls. In controls, 91% showed the activated area on the sensorimotor cortex after the finger opposition tasks. Before bypass, the resting SPECT revealed reduction of cerebral blood flow (CBF) on the affected side in all cases. All cases also showed a disturbed response to acetazolamide (ACZ). Nine cases were positive in the motor activation SPECT. One month after bypass, the resting CBF increased in 11 cases. Seven showed preoperative positive motor activation. Fifteen cases were positive in the motor activation SPECT. Three months after bypass, 20 cases showed improvement in the resting CBF, and 19 cases were positive in the motor activation SPECT. Ten cases were negative in the preoperative motor activation SPECT. At one month after surgery, ACZ activation SPECT was performed in 12 cases. Five showed improvement of the response to ACZ. At 3 months after surgery, 8 of 12 cases treated with ACZ activation SPECT showed improved response to ACZ. In most of the cases, improved response to ACZ could be seen after response to motor activation improved. STA-MCA bypass is useful not only for resting CBF but also for pure motor function based on motor activation SPECT. (K.H.)

  2. I-123 IMP SPECT in Parkinson's disease

    International Nuclear Information System (INIS)

    Kawabata, Keita; Tachibana, Kyudai; Sugita, Minoru

    1990-01-01

    To examine semiquantitatively regional cerebral blood flow, SPECT with N-isopropyl-p-[I-123]iodoamphetamine (I-123 IMP) was undertaken in 17 patients with Parkinson's disease. Seven patients with Alzheimer's disease and 9 senile control subjects were also imaged for comparison. Both the Parkinson's disease group and the Alzheimer's disease group had a decreased uptake of I-123 IMP in the frontal lobe, in comparison with the control group. A remarkably decreased uptake was seen in the lateral and parietal lobes in the group of Parkinson's disease associated with dementia, as well as in the Alzheimer's disease group. A significantly decreased uptake was observed in the frontal lobe, lateral lobe, thalamus, and basal ganglia in the Parkinson's disease group, irrespective of the presence or absence of dementia. For Parkinson's disease associated with dementia, there was much more significant decrease in I-123 IMP uptake. The pattern of regional cerebral blood flow in the Alzheimer's disease group was analogous to that in the Parkinson's disease group associated with dementia. This supports the hypothesis that Alzheimer's disease may be somewhat involved in the occurrence of dementia for Parkinson's disease. (N.K.)

  3. Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and 99mTc-tetrofosmin: Method and validation.

    Science.gov (United States)

    Shrestha, Uttam; Sciammarella, Maria; Alhassen, Fares; Yeghiazarians, Yerem; Ellin, Justin; Verdin, Emily; Boyle, Andrew; Seo, Youngho; Botvinick, Elias H; Gullberg, Grant T

    2017-02-01

    The objective of this study was to measure myocardial blood flow (MBF) in humans using 99m Tc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). Dynamic SPECT using 99m Tc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients were used to determine the flow-extraction curve for 99m Tc-tefrofosmin while data from the remaining 7 patients were used for method validation. The nonlinear tracer correction parameters A and B for 99m Tc-tefrofosmin were estimated for the 9 patients by fitting the flow-extraction curve [Formula: see text] for K 1 values estimated with 99m Tc-tefrofosmin using SPECT and MBF values estimated with 13 N-NH 3 using PET. These parameters were then used to calculate MBF and coronary flow reserve (CFR) in three coronary territories (LAD, RCA, and LCX) using SPECT for an independent cohort of 7 patients. The results were then compared with that estimated with 13 N-NH 3 PET. The flow-dependent permeability surface-area product (PS) for 99m Tc-tefrofosmin was also estimated. The estimated flow-extraction parameters for 99m Tc-tefrofosmin were found to be A = 0.91 ± 0.11, B = 0.34 ± 0.20 (R 2  = 0.49). The range of MBF in LAD, RCA, and LCX was 0.44-3.81 mL/min/g. The MBF between PET and SPECT in the group of independent cohort of 7 patients showed statistically significant correlation, r = 0.71 (P < .001). However, the corresponding CFR correlation was moderate r = 0.39 yet statistically significant (P = .037). The PS for 99m Tc-tefrofosmin was (0.019 ± 0.10)*MBF + (0.32 ± 0.16). Dynamic cardiac SPECT using 99m Tc-tetrofosmin and a clinical two-headed SPECT/CT scanner can be a useful tool for estimation of MBF.

  4. Regional cerebral blood flow studies with single photon emission computed tomography (SPECT); Clinical experiences, possibilities. Regionalis agyi veratfolyas vizsgalata egyfotonos emissios computer tomographiaval (SPECT); Klinikai tapasztalatok, lehetoesegek

    Energy Technology Data Exchange (ETDEWEB)

    Pavics, Laszlo; Csernay, Laszlo; Doczi, Tamas; Lang, Jenoe; Blaho, Gabor; Janka, Zoltan; Bodosi, Mihaly [Szegedi Orvostudomanyi Egyetem, Szeged (Hungary)

    1990-01-07

    Clinical experiences based on regional cerebral blood flow investigations with {sup 99m}Tc hexamethylpropyleneamin-oxime (HMPAO) SPECT in 164 patients are reported. The pharmacokinetics of the {sup 99m}Tc HMPAO are summarized, and the important indications of the investigations are interpreted in case reports (stroke, surgical solution of intracavernous aneurysm, Alzheimer and multiinfarct types of dementia). The literature data suggest that the diagnostic possibilities with this method are advantageous, even in other diseases. (author) 36 refs.; 7 figs.

  5. SPECT of the brain: Present and future

    International Nuclear Information System (INIS)

    Fazio, F.; Lenzi, G.L.

    1986-01-01

    In both PET and SPECT, most of the studies and the models have been addressed to two organs: brain and heart. So far, brain has certainly been investigated more. The several comparisons between planar scintigraphy and SPECT, between X-ray TCT and SPECT, and also between PET and SPECT, have tended to consider SPECT a cheap but scarcely useful tool for a nuclear medicine section. Again the authors feel that this is due to the fact that SPECT is really a ''physiological tomography'', with little known about its physiology or how it is measured. Thus the present state of the art of SPECT of the brain is characterized by a collection of data and reports on brain imaging and by a slowly growing basic understanding of the utilized modes. The introduction of a new brain-imaging radiopharmaceutical is immediately signaled by its ''first clinical application'' without parallel studies on the kinetics, the metabolic degradation, and the real suitability of the molecule as a tracer for measurement of regional CBF. Only a few attempts seek to narrow this discussion between clinic and biology, and the authors like to emphasize the need for nuclear medicine people to dedicate more time and effort

  6. Relationship between recurrence of esophageal varices and changes of portal circulation after endoscopic injection sclerotherapy

    International Nuclear Information System (INIS)

    Azuma, Masayoshi; Kashiwagi, Toru; Ohata, Hiroyuki

    1992-01-01

    The relationship between recurrence of esophageal varices after endoscopic injection sclerotherapy (EIS) and changes of the blood pool of portosystemic collaterals was studied in 36 patients with liver cirrhosis. Examination of the blood pool of portosystemic collaterals was performed by single photon emission CT (SPECT). Seven hundreds and forty MBq of 99m Tc-RBCs, labeled by an in vivo technique, were given intra-venously, and tomographic imaging of the intraabdominal vascular blood pool was performed. Before EIS, the blood pool images of the coronary vein was demonstrated in 34 cases (94.4%). According to changes of SPECT images, the patients were divided into 3 groups, that is, the groups showing a disappearance, decrease, and no changes of the blood pool images of the coronary vein. The recurrence rates of esophageal varices after EIS were 11.1% (1 of 9 patients), 40.0% (6 of 15 patients), and 90.0% (9 of 10 patients) in the disappeared, decreased and unchanged groups respectively. These values were significantly different between the disappeared group and the unchanged group (P<0.01), and between the decreased group and the unchanged group (P<0.05). These results indicate that the abdominal blood pool SPECT is useful for evaluating the therapeutic effectiveness of EIS. (author)

  7. Brain SPECT. SPECT in der Gehirndiagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Feistel, H. (Erlangen-Nuernberg Univ., Erlangen (Germany). Nuklearmedizinische Klinik mit Poliklinik)

    1991-12-01

    Brain SPECT investigations have gained broad acceptance since the introduction of the lipophilic tracer Tc-99m-HMPAO. Depending on equipment and objectives in different departments, the examinations can be divided into three groups: 1. Under normal conditions and standardised patient preparation the 'rest' SPECT can be performed in every department with a tomographic camera. In cerebrovascular disease there is a demand for determination of either the perfusion reserve in reversible ischemia or prognostic values in completed stroke. In cases of dementia, SPECT may yield useful results according to differential diagnosis. Central cerebral system involvement in immunologic disease may be estimated with higher sensitivity than in conventional brain imaging procedures. In psychiatric diseases there is only a relative indication for brain SPECT, since results during recent years have been contradictory and may be derived only in interventional manner. In brain tumor diagnostics SPECT with Tl-201 possibly permits grading. In inflammatory disease, especially in viral encephalitis, SPECT may be used to obtain early diagnosis. Normal pressure hydrocephalus can be distinguished from other forms of dementia and, consequently, the necessity for shunting surgery can be recognised. 2. In departments equipped for emergency cases an 'acute' SPECT can be performed in illnesses with rapid changing symptoms such as different forms of migraine, transient global amnesia, epileptic seizures (so-called 'ictal SPECT') or urgent forms like trauma. 3. In cooperation with several departments brain SPECT can be practised as an interventional procedure in clinical and in scientific studies. (orig./MG).

  8. Clinical usefulness of normal data bases comparisons for the SPECT diagnosis of Alzheimer's disease

    International Nuclear Information System (INIS)

    Darcourt, J.; Koulibaly, P.M.; Migneco, O.; Dygai, I.; Robert, P.H.; Nobili, F.; Ebmeir, K.

    2002-01-01

    Aim. The possible added value of voxel by voxel comparisons to normal data bases has not been evaluated for the diagnosis of Alzheimer's disease (AD). We conducted a prospective comparison of the diagnostic performances of 2 software packages: Statistical Parametric Mapping (SPM) (Friston et al.) and NeuroGam (NGam) (Segami Corporation). Materials and methods. A total of 152 subjects (age ≥ 50 years) were included: 93 AD, 28 depressed patients and 31 normal controls (NC). They were studied in 4 centers as part of a European project 'SPECT in dementia' BMH4-98-3130. NC were used to build the normal data bases and the total population was submitted to the readers for the diagnosis of AD. AD final diagnosis was based on NINCDS/ADRDA criteria for probable AD and DSM-IV criteria for dementia of AD type. SPECT scans were obtained in each center with dedicated cameras 30 to 90 min after i.v. injection of 250 to 925 MBq of 99mTc-HMPAO. All data were reconstructed on the same workstation by filtered backprojection with attenuation correction. The 4.7 mm thick cuts (CUTS) were displayed in the transverse, sagittal and coronal planes with the same color scale. They also were submitted to the 2 packages tested. For SPM, we used SPM'96 for Windows'95. For each individual scan we computed the corresponding z-map by comparison to the NC data base. We used p<0.01 to threshold the t-maps and a p corrected value <0.01 on intensity for cluster selection. For NGam, the same NC were used to build the normal data base. Each individual scan was then compared to this base and the results consisted in a 3D parametric image of voxel by voxel standard deviations form the normal mean value. 4 expert readers (more than 3 years experience; more than 5 SPECT per week) were asked to class the scans as AD or not with a 4 degree of confidence. They reviewed the CUTS alone, CUTS+SPM and CUTS+NGam. ROC analysis was performed and the areas under curves (AUC) statistically compared. Results. Average

  9. Effects of partial volume correction on discrimination between very early Alzheimer's dementia and controls using brain perfusion SPECT

    International Nuclear Information System (INIS)

    Kanetaka, Hidekazu; Matsuda, Hiroshi; Ohnishi, Takashi; Imabayashi, Etsuko; Tanaka, Fumiko; Asada, Takashi; Yamashita, Fumio; Nakano, Seigo; Takasaki, Masaru

    2004-01-01

    We assessed the accuracy of brain perfusion single-photon emission computed tomography (SPECT) in discriminating between patients with probable Alzheimer's disease (AD) at the very early stage and age-matched controls before and after partial volume correction (PVC). Three-dimensional MRI was used for PVC. We randomly divided the subjects into two groups. The first group, comprising 30 patients and 30 healthy volunteers, was used to identify the brain area with the most significant decrease in regional cerebral blood flow (rCBF) in patients compared with normal controls based on the voxel-based analysis of a group comparison. The second group, comprising 31 patients and 31 healthy volunteers, was used to study the improvement in diagnostic accuracy provided by PVC. A Z score map for a SPECT image of a subject was obtained by comparison with mean and standard deviation SPECT images of the healthy volunteers for each voxel after anatomical standardization and voxel normalization to global mean or cerebellar values using the following equation: Z score = ([control mean]-[individual value])/(control SD). Analysis of receiver operating characteristics curves for a Z score discriminating AD and controls in the posterior cingulate gyrus, where a significant decrease in rCBF was identified in the first group, showed that the PVC significantly enhanced the accuracy of the SPECT diagnosis of very early AD from 73.9% to 83.7% with global mean normalization. The PVC mildly enhanced the accuracy from 73.1% to 76.3% with cerebellar normalization. This result suggests that early diagnosis of AD requires PVC in a SPECT study. (orig.)

  10. Usefulness of {sup 99m}Tc-ECD brain SPECT in acute onset pediatric CNS diseases. In comparison with CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Teisuke; Chikatsu, Hiroko; Nishiyama, Hiromune; Endo, Hiroko; Kono, Tatsuo; Iimura, Fumitoshi; Kuwashima, Shigeko; Saiki, Natoru; Fujioka, Mutsuhisa [Dokkyo Univ., Mibu, Tochigi (Japan). School of Medicine

    2001-07-01

    The purpose of this study was to assess the usefulness of regional cerebral blood flow (rCBF) measured by {sup 99m}Tc-L, L-ethyl cysteinate dimer (ECD) brain SPECT in the acute onset type of pediatric central nervous system (CNS) diseases. Thirteen children (7 girls, 6 boys, 4 month-12 years of age) who were diagnosed with 9 cases of viral encephalitis, two cases of febrile convulsion and one each of migraine and metabolic disorder underwent {sup 99m}Tc-ECD brain SPECT, CT and/or MRI within one week interval. The incidence of abnormal findings in the 13 patients was 96.4% (30/31) on {sup 99m}Tc-ECD brain SPECT, 17.6% (3/17) on CT and 63.6% (14/22) on MRI. The positive detection rate of {sup 99m}Tc-ECD brain SPECT was statistically (P<0.01 by a {chi}{sup 2} and/or Fisher's exact probability test) higher than those of CT and MRI. And the changes in rCBF were demonstrated. {sup 99m}Tc-ECD brain SPECT is a useful examination for the diagnosis and follow up management in patients with the acute onset type of pediatric CNS diseases. (author)

  11. Feasibility and preliminary results of SPECT/CT arthrography of the wrist in comparison with MR arthrography in patients with suspected ulnocarpal impaction

    Energy Technology Data Exchange (ETDEWEB)

    Strobel, Klaus [Lucerne Cantonal Hospital, Department of Nuclear Medicine and Radiology, Lucerne (Switzerland); Kantonsspital Luzern, Roentgeninstitut/Nuklearmedizin, Luzern (Switzerland); Steurer-Dober, Isabelle; Huellner, Martin W.; Sol Perez Lago, Maria del; Veit-Haibach, Patrick; Tornquist, Katharina [Lucerne Cantonal Hospital, Department of Nuclear Medicine and Radiology, Lucerne (Switzerland); Silva, Angela J. da [Advanced Molecular Imaging, Philips Healthcare, San Jose, CA (United States); Bodmer, Elvira; Wartburg, Urs von; Hug, Urs [Lucerne Cantonal Hospital, Division of Hand and Plastic Surgery, Lucerne (Switzerland)

    2014-03-15

    To evaluate the feasibility and performance of SPECT/CT arthrography of the wrist in comparison with MR arthrography in patients with suspected ulnocarpal impaction. This prospective study included 28 wrists of 27 patients evaluated with SPECT/CT arthrography and MR arthrography. Iodine contrast medium and gadolinium were injected into the distal radioulnar and midcarpal joints. Late-phase SPECT/CT was performed 3.5 h after intravenous injection of approximately 650 MBq {sup 99m}Tc-DPD. MR and SPECT/CT images were separately reviewed in relation to bone marrow oedema, radionuclide uptake, and tears in the scapholunate (SL) and lunotriquetral (LT) ligaments and triangular fibrocartilage complex (TFCC), and an overall diagnosis of ulnar impaction. MR, CT and SPECT/CT imaging findings were compared with each other, with the surgical findings in 12 patients and with clinical follow-up. The quality of MR arthrography and SPECT/CT arthrography images was fully diagnostic in 23 of 28 wrists (82 %) and 25 of 28 wrists (89 %), respectively. SPECT/CT arthrography was not diagnostic for ligament lesions due to insufficient intraarticular contrast in one wrist. MR and SPECT/CT images showed concordant findings regarding TFCC lesions in 22 of 27 wrists (81 %), SL ligament in 22 of 27 wrists (81 %) and LT ligament in 23 of 27 wrists (85 %). Bone marrow oedema on MR images and scintigraphic uptake were concordant in 21 of 28 wrists (75 %). MR images showed partial TFCC defects in four patients with normal SPECT/CT images. MR images showed bone marrow oedema in 4 of 28 wrists (14 %) without scintigraphic uptake, and scintigraphic uptake was present without MR bone marrow oedema in three wrists (11 %). Regarding diagnosis of ulnar impaction the concordance rate between CT and SPECT/CT was 100 % and reached 96 % (27 of 28) between MR and SPECT/CT arthrography. The sensitivity and specificity of MR, CT and SPECT/CT arthrography were 93 %, 100 % and 100 %, and 93 %, 93 % and 93

  12. 123I-IMP SPECT study on patients with amnestic syndrome

    International Nuclear Information System (INIS)

    Hanyu, Haruo; Abe, Shinei; Arai, Hisayuki; Takasaki, Masaru; Suzuki, Takanari; Abe, Kimihiko; Amino, Saburo

    1992-01-01

    Regional cerebral blood flow was studied using single photon emission CT (SPECT) with 123 I-IMP to elucidate the pathophysiology of amnesia. Four patients with amnestic syndrome diagnosed by DSM-III-R criteria were investigated. SPECT images demonstrated definite hypoperfusion of the temporoparietal lobe and relative sparing of motorsensory and occipital cortices in two out of four patients. Since these abnormalities of regional cerebral blood flow have been considered to be characteristic findings in dementia of the Alzheimer type, two patients with temporoparietal hypoperfusion are suggested to manifest the early stage of dementia of the Alzheimer type. Our observations suggest that 123 I-IMP SPECT is an useful madality in the diagnosis of the early stage of dementia of the Alzheimer type, especially in patients with only memory impairment. (author)

  13. Functional regional cerebral blood flow SPECT using 99mTc-HM-PAO by speech memory tasks

    International Nuclear Information System (INIS)

    Tohyama, Junko

    1993-01-01

    Using single photon emission computed tomography (SPECT) with Tc-99m HA-PAO, changes in regional cerebral blood flow (rCBF) by giving word memory and Miyake's tasks were determined for localizatin of speech memory function. Twice injection method of Tc-99m HM-PAO was used to obtain subtraction SPECT images; and positioning of the 1st and 2nd SPECT was determined by phantom study. To prevent artifacts and changes in rCBF as far as possible, the subjects were informed word fluency and Miyake's tasks sufficiently. When giving word fluency approach, an increase in rCBF was observed in both the operculum and the supratemporal convolution of dominant hemisphere. When giving Miyake's approach, it was observed predominantly in the supratemporal convolution of dominant hemisphere. Although it was also observed in the base of frontal lobe and operculum, there was no bilateral difference. An increased rCBF in the basal nucleus was more clearly observed by Miyake's than word fluency tasks without bilateral differences. There was no definitive increase in rCBF in the Papez's circuit responsible for memory and emotion by either word fluency or Miyake's tasks. In mentally mild disorder patients, an increased rCBF was observed in the same areas as those in normal subjects. In such patients having a decreased rCBF at rest, an increased rCBF was seen in the contralateral hemisphere and the surrounding areas of the lesions, suggesting compensatory mechanism. (N.K.) 65 refs

  14. Contrasted study on the opening degree of blood-brain barriier after radiation therapy with SPECT and MRI

    International Nuclear Information System (INIS)

    Zhang Qing; Sun Aihua; Hu Yun; Zhang Li; Ye Hengguang

    2004-01-01

    The blood-brain barrier(BBB) is the largest barrier responsible for preventing direct contact between chemotherapeutic drugs in blood and tumors in brain, the permeability of BBB incease at different degree after brain irradiation in clinical brain tumors radiotherapy. Methods: In our study, 26 patients with metastatic brain tumors(21 cases in pr/mary lung carcinoma, 5 cases in breast carcinoma) were accepted the full brain irradiation. The detructive effects of radiation on the BBB were determined by the 99mTc-DTPA SPECT and the concentration ratio of methotrexate(MTX) in cerebrospinal fluid(CSF) and blood, the brain MRI before and after radiotherapy were retrospective contrasted study with SPECT. Results: the degree of destructive effect on the BBB was directly proportional to radiation doses. After a dose of 20Gy radiation to brain, the permeability of BBB inceased markedly(P<0.01). But in cases the dexamethasone(DXM) was administrated to decease the brain edema during radiotherapy, the permeability inceased less than that in patients without DXM(P<0.05). Conclutions: After 20Gy irradiation, the BBB would gradually open. At this time, chemotherapy is the best choice to improving the therapeutic effect. Dexamethasone was found to cause the decease in BBB permeability but no significant remission of brain edema. So, if the combination of radiotherapy and chemotherapy in treatment of metastatic brain tumors will be plan, the dexamethasone may be not used in expecting to deceasing the side effect and that no affecting the therapeutic effect. (authors)

  15. Comparison between CT perfusion and Tc-99m ECD SPECT in the assessment of cerebrovascular reserve: a case study

    International Nuclear Information System (INIS)

    Crouch, J.; Wood, C.; Campbell, A.; McCarthy, M.; Dunne, M.; Bynevelt, M.; Lenzo, N.

    2003-01-01

    Full text: Brain perfusion is sensitively assessed by cerebral SPECT imaging utilising perfusion agents such as Tc-99m HMPAO and Tc-99m ethyl cysteinate dimer (ECD). Positron emission tomography can accurately assess and quantify brain perfusion and MRI can also be used for perfusion assessment. Both MRI and PET however are currently limited by cost and availability. A new technique utilising CT with contrast has been developed to assess and quantitate cerebral perfusion. The technique utilises arterial input information and deconvolution analysis to develop quantifiable measures of perfusion and contrast transit. The technique has been validated for acute stroke assessment and is being assessed for other possible applications. We present a case study comparison of this technique with cerebral SPECT perfusion using Tc-99m ECD in the assessment of cerebrovasular reserve. In each case, the CT and SPECT studies were performed pre- and post-acetazolamide and the SPECT study was statistically compared with a normal database utilising an automated brain perfusion statistical analysis package (NeurostatT). We discuss the correlation found between techniques, their strengths, weaknesses and possible future roles. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  16. SPECT/CT Fusion in the Diagnosis of Hyperparathyroidism

    International Nuclear Information System (INIS)

    Monzen, Yoshio; Tamura, Akihisa; Okazaki, Hajime; Kurose, Taichi; Kobayashi, Masayuki; Kuraoka, Masatsugu

    2015-01-01

    In this study, we aimed to analyze the relationship between the diagnostic ability of fused single photon emission computed tomography/ computed tomography (SPECT/CT) images in localization of parathyroid lesions and the size of adenomas or hyperplastic glands. Five patients with primary hyperparathyroidism (PHPT) and 4 patients with secondary hyperparathyroidism (SHPT) were imaged 15 and 120 minutes after the intravenous injection of technetium99m-methoxyisobutylisonitrile ( 99m Tc-MIBI). All patients underwent surgery and 5 parathyroid adenomas and 10 hyperplastic glands were detected. Pathologic findings were correlated with imaging results. The SPECT/CT fusion images were able to detect all parathyroid adenomas even with the greatest axial diameter of 0.6 cm. Planar scintigraphy and SPECT imaging could not detect parathyroid adenomas with an axial diameter of 1.0 to 1.2 cm. Four out of 10 (40%) hyperplastic parathyroid glands were diagnosed, using planar and SPECT imaging and 5 out of 10 (50%) hyperplastic parathyroid glands were localized, using SPECT/CT fusion images. SPECT/CT fusion imaging is a more useful tool for localization of parathyroid lesions, particularly parathyroid adenomas, in comparison with planar and or SPECT imaging

  17. Pool swell sub-scale testing and code comparison

    International Nuclear Information System (INIS)

    Elisson, K.

    1981-01-01

    The main objective of the experiment was to investigate the pool swell dynamics in general and the forces on the lowered central part of the diaphragm between drywell and wetwell in particular. Apart from the high speed camera pressure transducers and strain gauges were used to monitor the transient. Data was recorded on a 14 channel FM recorder and then digitalised and plotted. In total more than one hundred tests were performed including parametric variations of for example geometry, break flow, initial drywell pressure and initial water level. In parallel to this experiment pool swell calculations have been performed with the computer codes COPTA and STEALTH. COPTA which is a lumped mass code for pressure suppression containment analysis has a slug pool swell mode. STEALTH which is a general purpose lagrangian hydrodynamics code has been used in a 2-D axisymmetric version. The STEALTH code has been used to calculate the radial variations in the vertical displacement and velocity of the pool surface and to predict the load on the lowered central part of the diaphragm. A comparison between the calculations and the experimental data indicates that both codes are sufficiently correct in their description of the pool swell transient. (orig.)

  18. Validation and the limits of SPECT for patients suffering from cerebrovascular accidents. Evaluations based on simultaneous PET and SPECT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Mizukawa, Norihiko; Yano, Ichiro; Tenjin, Hiroshi (Kyoto Prefectural Univ. of Medicine (Japan)) (and others)

    1989-02-01

    Contemporaneous single photon emission computed tomography (SPECT) and positron emission tomography (PET) were performed in 10 patients with cerebrovascular accidents (CVA), whose ages ranged from 11 to 67 years. I-123-isopropyl-iodoamphetamine (IMP) and/or Tc-99m hexamethylpropyleneamine oxime (HM-PAO) were used for SPECT. Cerebral blood flow (CBF), oxygen extraction fraction (OEF), and cerebral metabolic rate for oxygen (CMRO{sub 2}) were measured by an O-15 labelled gas continuous-inhalation method. SPECT images were quite similar to CBF and CMRO{sub 2} during the chronic stage of CVA. Two patietns with vasospasm during the subacute stage had apparently low CBF and CMRO{sub 2} on PET, but did not have low perfusion on SPECT. Luxury perfusion areas were detected in 4 subacute stage patients and one chronic stage patient. A redistribution of IMP was detected in two patients with infarction during subacute stage. CMRO{sub 2} value in such an area was 2.0 ml/100 g/min. Low CBF and/or CMRO{sub 2} areas were well visualized by IMP rather than by HM-PAO SPECT. (N.K.).

  19. Interest of hybrid SPECT-CT imaging for diagnosis of infection

    International Nuclear Information System (INIS)

    Riviere, A.; Farid, K.; Guyot, M.; Jeandot, R.; Allard, M.; Fernandez, P.; Clermont, H. de; Dauchy, F.; Dupon, M.; Fernandez, P.

    2008-01-01

    Single-Photon Emission Computed Tomography-Computerized Tomography (SPECT-CT) is a new hybrid technique which offers new diagnostic capabilities in daily nuclear medicine practice. This technique not only allows to acquire merged anatomic and functional images in the same time, but also, it increases sensitivity and accuracy of SPECT thanks to attenuation and scattering corrections got from transmission data. Until now, SPECT-CT data have been mainly obtained in oncology and cardiology, but now, many authors use it in many scan studies and particularly for infectious diseases. In inflammatory bowel diseases, SPECT-CT seems to increase diagnostic performances and to modify management of many patients. In suspected vascular sepsis, SPECT-CT could increase sensitivity of white blood cell scintigraphy but also its specificity thanks to spatial resolution of CT. In osteo-articular sepsis, SPECT-CT has the advantage to distinguish osteomyelitis from soft tissue infection and to guide biopsies. Nevertheless, in the light of PET-CT works, SPECT-CT development will probably modify nuclear medicine practice and many studies have to be conducted to highlight consensual procedure guidelines. (authors)

  20. Gated cardiac blood pool studies in arrhythmias

    International Nuclear Information System (INIS)

    Itti, R.; Casset, D.; Philippe, L.; Cosnay, P.; Fauchier, J.P.

    1988-01-01

    Biventricular phase analysis a gated blood pool studies may help to solve two fundamental questions raised by patients suffering from arrhythmias: localization of an electrical cardiac activation abnormality by means of contraction mapping and assesment of an underlying organic disease using the phase histograms and their standard deviations. Three groups of patients have been evaluated to demonstrate the usefulness of radioisotopic techniques in arrhythmias: 36 patients with a Wolff-Parkinson-White syndrom, 27 patients studied during a ventricular tachycardia attack and 32 patients suspected of arrhythmogenic ventricular dysplasia. Correlations with invasive electrophysiologic studies are presented and the diagnostic and therapeutic implications of these results are discussed [fr

  1. Gated cardiac blood pool studies in arrhythmias

    Energy Technology Data Exchange (ETDEWEB)

    Itti, R.; Casset, D.; Philippe, L.; Cosnay, P.; Fauchier, J.P.

    1988-01-01

    Biventricular phase analysis a gated blood pool studies may help to solve two fundamental questions raised by patients suffering from arrhythmias: localization of an electrical cardiac activation abnormality by means of contraction mapping and assesment of an underlying organic disease using the phase histograms and their standard deviations. Three groups of patients have been evaluated to demonstrate the usefulness of radioisotopic techniques in arrhythmias: 36 patients with a Wolff-Parkinson-White syndrom, 27 patients studied during a ventricular tachycardia attack and 32 patients suspected of arrhythmogenic ventricular dysplasia. Correlations with invasive electrophysiologic studies are presented and the diagnostic and therapeutic implications of these results are discussed.

  2. Clinical comparison of 99mTc exametazime and 123I Ioflupane SPECT in patients with chronic mild traumatic brain injury.

    Directory of Open Access Journals (Sweden)

    Andrew B Newberg

    Full Text Available BACKGROUND: This study evaluated the clinical interpretations of single photon emission computed tomography (SPECT using a cerebral blood flow and a dopamine transporter tracer in patients with chronic mild traumatic brain injury (TBI. The goal was to determine how these two different scan might be used and compared to each other in this patient population. METHODS AND FINDINGS: Twenty-five patients with persistent symptoms after a mild TBI underwent SPECT with both (99mTc exametazime to measure cerebral blood flow (CBF and (123I ioflupane to measure dopamine transporter (DAT binding. The scans were interpreted by two expert readers blinded to any case information and were assessed for abnormal findings in comparison to 10 controls for each type of scan. Qualitative CBF scores for each cortical and subcortical region along with DAT binding scores for the striatum were compared to each other across subjects and to controls. In addition, symptoms were compared to brain scan findings. TBI patients had an average of 6 brain regions with abnormal perfusion compared to controls who had an average of 2 abnormal regions (p<0.001. Patient with headaches had lower CBF in the right frontal lobe, and higher CBF in the left parietal lobe compared to patients without headaches. Lower CBF in the right temporal lobe correlated with poorer reported physical health. Higher DAT binding was associated with more depressive symptoms and overall poorer reported mental health. There was no clear association between CBF and DAT binding in these patients. CONCLUSIONS: Overall, both scans detected abnormalities in brain function, but appear to reflect different types of physiological processes associated with chronic mild TBI symptoms. Both types of scans might have distinct uses in the evaluation of chronic TBI patients depending on the clinical scenario.

  3. Evaluation of liver function in carbon tetrachloride-damaged rabbits by dynamic SPECT. Comparison of 99mTc-GSA and 99mTc-Sn colloid

    International Nuclear Information System (INIS)

    Kiuchi, Takaaki; Kawasaki, Yukiko; Hino, Ichirou; Kojima, Kanji; Ohkawa, Motoomi; Tanabe, Masatada; Tamai, Toyosato.

    1994-01-01

    Technetium-99m-DTPA-galactosyl human serum albumin ( 99m Tc-GSA) is a new ligand that binds specifically to asialoglycoprotein receptors in hepatocytes. We performed liver dynamic SPECT using 99m Tc-GSA and 99m Tc-Sn colloid in nine normal control rabbits and 17 chronically CCl 4 -damaged rabbits (total 29 examinations), and also performed liver function tests (ICGR 15 , Alb, etc). Using the obtained dynamic SPECT data, we analyzed the liver kinetics of 99m Tc-Sn colloid using a one-compartment model (hepatic blood flow [K]) and 99m Tc-GSA using a two-compartment model (hepatic blood flow and receptor binding [K 1 ], catabolism [K 2 ]). As the CCl 4 -treated period increased, K 1 decreased most significantly. K 1 showed the most statistically significant correlation with the results of liver function tests, ICGR 15 (p 1 showed a correlation with the hepatic fibrosis of the HAI score. From the present results, liver dynamic SPECT using 99m Tc-GSA may be said to provide a novel method for the evaluation of hepatic functional reserve. (author)

  4. Comparison of SPECT and CT in detecting skull base invasion in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Zhang Li; Wang Jinchuan; Pu Nuo; Song Wenzhong; Chen Mingxi

    2002-01-01

    Objective: To investigate the detecting ability of single photon emission computed tomography (SPECT) and CT in skull base invasion in nasopharyngeal carcinoma. Methods: Sixty-three patients with nasopharyngeal carcinoma were examined by whole body and skull base SPECT and CT of nasopharynx and skull base before radiotherapy. The results were double-blind compared and evaluated. Results: The overall positive rates of skull base invasion detected by SPECT and CT were 63.5% and 25.4%. In patients with headache, cranial nerve palsy and both, they were 87.9%, 93.3%, 92.3% and 42.4%, 46.7%, 46.2%. In patients with T 1 + T 2 and T 3 + T 4 lesions, they were 37.5%, 90.3% and 0.0%, 51.6%. In patients with N 0 + N 1 and N 2 + N 3 lesions, they were 63.9%, 63.0% and 19.4%, 33.3%. The positive rates of SPECT were higher than those of CT (McNemar Test, P < 0.05). The conformation rate between SPECT and CT was 61.9% and the dissimilitude rate was 38.1%. Binary Logistic regression analysis showed that headache and T stages were risk factors of positive SPECT rate (ORheadache = 3.864, ORTstage= 6.422) while Tstage and Nstage were the risk factors for positive CT rate (ORTstage = 48.932, ORNstage = 2.860). Conclusions: The detection sensitivity of SPECT in skull base invasion in nasopharyngeal carcinoma is superior to that of CT. But its specificity is inferior to that of CT. The detecting results in SPECT are better related to symptoms, signs and stage. Combining headache and cranial nerve palsy with T and N stage, the authors may much improve the results of SPECT and CT in the detection of skull base invasion in nasopharyngeal carcinoma. Further study is warranted

  5. First validation of myocardial flow reserve assessed by dynamic 99mTc-sestamibi CZT-SPECT camera: head to head comparison with 15O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study.

    Science.gov (United States)

    Agostini, Denis; Roule, Vincent; Nganoa, Catherine; Roth, Nathaniel; Baavour, Raphael; Parienti, Jean-Jacques; Beygui, Farzin; Manrique, Alain

    2018-07-01

    We assessed the feasibility of myocardial blood flow (MBF) and flow reserve (MFR) estimation using dynamic SPECT with a novel CZT camera in patients with stable CAD, in comparison with 15 O-water PET and fractional flow reserve (FFR). Thirty patients were prospectively included and underwent FFR measurements in the main coronary arteries (LAD, LCx, RCA). A stenosis ≥50% was considered obstructive and a FFR abnormal if ≤0.8. All patients underwent a dynamic rest/stress 99m Tc-sestamibi CZT-SPECT and 15 O-water PET for MBF and MFR calculation. Net retention kinetic modeling was applied to SPECT data to estimate global uptake values, and MBF was derived using Leppo correction. Ischemia by PET and CZT-SPECT was considered present if MFR was lower than 2 and 2.1, respectively. CZT-SPECT yielded higher stress and rest MBF compared to PET for global and LAD and LCx territories, but not in RCA territory. MFR was similar in global and each vessel territory for both modalities. The sensitivity, specificity, accuracy, positive and negative predictive value of CZT-SPECT were, respectively, 83.3, 95.8, 93.3, 100 and 85.7% for the detection of ischemia and 58.3, 84.6, 81.1, 36.8 and 93% for the detection of hemodynamically significant stenosis (FFR ≤ 0.8). Dynamic 99m Tc-sestamibi CZT-SPECT was technically feasible and provided similar MFR compared to 15 O-water PET and high diagnostic value for detecting impaired MFR and abnormal FFR in patients with stable CAD.

  6. Pulmonary capillary wedge pressure, as inferred from lung areas in gated blood-pool scintigrams: concise communication

    International Nuclear Information System (INIS)

    Urbina, A.; Okada, R.D.; Palacios, I.; Osbakken, M.; Strauss, H.W.

    1981-01-01

    To determine whether the apex-to-base distribution of pulmonary blood volume, as obtained from gated cardiac blood-pool scans, could be used as a noninvasive method to estimate mean pulmonary capillary wedge pressure (PCWP), gated blood-pool scans were analyzed in 77 patients who also had PCWP measurements at cardiac catheterization. Ten of these patients had gated cardiac blood-pool scans and PCWP measurements both at rest and during exercise. The apex-to-base distribution of pulmonary blood volume was determined from the end-systolic frame of the left anterior oblique view by placing equal-sized regions of interest over the apex and base of the right lung. The ratio of apex counts over base counts (A/B ratio) was considered abnormal if greater than unity. The mean A/B ratio was 1.15 +/- 0.27 (1 s.d.) for the 32 studies associated with an abnormal mean PCWP (greater than 12 mm Hg). The mean A/B ratio was 0.85 +/- 0.23 for the 55 studies associated with a normal mean PCWP (p less than 0.01 comparing normal group with abnormal). The sensitivity of the A/B ratio for a mean PCWP greater than 12 mm Hg was 81%R (26/32). The specificity of the A/B ratio for a mean PCWP greater than or equal to 12 mm Hg was 89% (49/55). Thus, noninvasive determination of the pulmonary apex-to-base ratio from gated cardiac blood-pool scans appears to differentiate subjects with normal and abnormal mean pulmonary capillary wedge pressures

  7. Quantitation of myocardial blood flow and myocardial flow reserve with {sup 99m}Tc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Bailing [University of Missouri-Columbia, Nuclear Science and Engineering Institute, Columbia, MO (United States); Chen, Fu-Chung; Chen, Chien-Cheng [Show Chwan Memorial Hospital, Section of Cardiology, Department of Internal Medicine, Changhua (China); Wu, Tao-Cheng [Taipei Veterans General Hospital, Section of Cardiology, Department of Internal Medicine, Taipei (China); Huang, Wen-Sheng [Changhua Christian Hospital, Department of Medical Research and Department of Nuclear Medicine, Changhua (China); Hou, Po-Nien [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Lukong Town, Changhua Shien (China); Hung, Guang-Uei [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Lukong Town, Changhua Shien (China); Central Taiwan University of Science and Technology, Department of Medical Imaging and Radiological Science, Taichung (China); China Medical University, Department of Biomedical Imaging and Radiological Science, Taichung (China)

    2014-12-15

    Conventional dual-head single photon emission computed tomography (SPECT)/CT systems capable of fast dynamic SPECT (DySPECT) imaging have a potential for flow quantitation. This study introduced a new method to quantify myocardial blood flow (MBF) and myocardial flow reserve (MFR) with DySPECT scan and evaluated the diagnostic performance of detecting coronary artery disease (CAD) compared with perfusion using invasive coronary angiography (CAG) as the reference standard. This study included 21 patients with suspected or known CAD who had received DySPECT, ECG-gated SPECT (GSPECT), and CAG (13 with ≥50 % stenosis in any vessel; non-CAD group: 8 with patent arteries or <50 % stenosis). DySPECT and GSPECT scans were performed on a widely used dual-head SPECT/CT scanner. The DySPECT imaging protocol utilized 12-min multiple back-and-forth gantry rotations during injections of {sup 99m}Tc-sestamibi (MIBI) tracer at rest or dipyridamole-stress stages. DySPECT images were reconstructed with full physical corrections and converted to the physical unit of becquerels per milliliter. Stress MBF (SMBF), rest MBF (RMBF), and MFR were quantified by a one-tissue compartment flow model using time-activity curves derived from DySPECT images. Perfusion images were processed for GSPECT scan and interpreted to obtain summed stress score (SSS) and summed difference score (SDS). Receiver-operating characteristic (ROC) analyses were conducted to evaluate the diagnostic performance of flow and perfusion. Using the criteria of ≥50 % stenosis as positive CAD, areas under the ROC curve (AUCs) of flow assessment were overall significantly greater than those of perfusion. For patient-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.91 ± 0.07, 0.86 ± 0.09, 0.64 ± 0.12, and 0.59 ± 0.13. For vessel-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.81 ± 0.05, 0.76 ± 0.06, 0.62 ± 0.07, and 0.56 ± 0.08, respectively. The preliminary data suggest that MBF quantitation with a

  8. Gene expression changes in blood RNA after swimming in a chlorinated pool.

    Science.gov (United States)

    Salas, Lucas A; Font-Ribera, Laia; Bustamante, Mariona; Sumoy, Lauro; Grimalt, Joan O; Bonnin, Sarah; Aguilar, Maria; Mattlin, Heidi; Hummel, Manuela; Ferrer, Anna; Kogevinas, Manolis; Villanueva, Cristina M

    2017-08-01

    Exposure to disinfection by-products (DBP) such as trihalomethanes (THM) in swimming pools has been linked to adverse health effects in humans, but their biological mechanisms are unclear. We evaluated short-term changes in blood gene expression of adult recreational swimmers after swimming in a chlorinated pool. Volunteers swam 40min in an indoor chlorinated pool. Blood samples were drawn and four THM (chloroform, bromodichloromethane, dibromochloromethane and bromoform) were measured in exhaled breath before and after swimming. Intensity of physical activity was measured as metabolic equivalents (METs). Gene expression in whole blood mRNA was evaluated using IlluminaHumanHT-12v3 Expression-BeadChip. Linear mixed models were used to evaluate the relationship between gene expression changes and THM exposure. Thirty-seven before-after pairs were analyzed. The median increase from baseline to after swimming were: 0.7 to 2.3 for MET, and 1.4 to 7.1μg/m 3 for exhaled total THM (sum of the four THM). Exhaled THM increased on average 0.94μg/m 3 per 1 MET. While 1643 probes were differentially expressed post-exposure. Of them, 189 were also associated with exhaled levels of individual/total THM or MET after False Discovery Rate. The observed associations with the exhaled THM were low to moderate (Log-fold change range: -0.17 to 0.15). In conclusion, we identified short-term gene expression changes associated with swimming in a pool that were minor in magnitude and their biological meaning was unspecific. The high collinearity between exhaled THM levels and intensity of physical activity precluded mutually adjusted models with both covariates. These exploratory results should be validated in future studies. Copyright © 2017. Published by Elsevier B.V.

  9. Quantitative assessment of cerebral blood flow by 123I-IMP SPECT

    International Nuclear Information System (INIS)

    Moriwaki, Hiroshi; Matsumoto, Masayasu; Hashikawa, Kazuo

    1993-01-01

    To establish a noninvasive, quantitative method for measuring regional cerebral blood flow (rCBF) by N-isopropyl-p-[ 123 I]iodoamphetamine ( 123 I-IMP) SPECT, we attempted to employ continuous venous sampling instead of arterial sampling. Forty two patients with cerebrovascular disease were classified into two groups, with (group II: n=35) and without (group I: n=7) hand warming. In group II, either hand was warmed, wrapping in a hot blanket (group IIA) or immersed in a 44degC water bath (group IIB). Immediately after intravenous bolus injection of 222 MBq IMP, arterial and venous blood samples were collected continuously for 5 min from the radial artery and the cubital vein, respectively. By octanol extraction, IMP was divided into the unmetabolized and metabolized fractions. The ratio of 123 I-IMP of venous blood to arterial blood (pass ratio, referred to as %PR) was calculated in the whole blood, unmetabolized, and metabolized fractions. Using these parameters, we assessed the possibility to estimate the amount of unmetabolized IMP fraction of arterial blood, usually used as an input function, from venous samples. In group I, %PR demonstrated a considerable variation between individuals (whole IMP, 47.5±24.6%; unmetabolized IMP, 46.0±24.5%; metabolized IMP, 51.8±27.4%). In group II, especially in group IIB, both increase of %PR value and the decrease in variation (whole, 77.9±5.6%; unmetabolized, 75.7±5.7%; metabolized, 86.7±8.7%) were observed, permitting the further calculation based on the assumption that %PR value was constant in each IMP fraction. The coefficient of variation of the difference between estimated arterial IMP radioactivity from venous samples and actual arterial IMP was 9.0% and 7.5%. The use of venous sampling coupled with a hand warming technique allowed the estimation of the arterial unmetabolized IMP radioactivity from venous samples with a reliability of 90% or more. (author)

  10. The origins of SPECT and SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Hutton, Brian F. [University College London, Institute of Nuclear Medicine, London (United Kingdom); University of Wollongong, Centre for Medical Radiation Physics, Wollongong, NSW (Australia)

    2014-05-15

    Single photon emission computed tomography (SPECT) has a long history of development since its initial demonstration by Kuhl and Edwards in 1963. Although clinical utility has been dominated by the rotating gamma camera, there have been many technological innovations with the recent popularity of organ-specific dedicated SPECT systems. The combination of SPECT and CT evolved from early transmission techniques used for attenuation correction with the initial commercial systems predating the release of PET/CT. The development and acceptance of SPECT/CT has been relatively slow with continuing debate as to what cost/performance ratio is justified. Increasingly, fully diagnostic CT is combined with SPECT so as to facilitate optimal clinical utility. (orig.)

  11. Myocardial viability assessment with gated SPECT Tc-99m tetrofosmin % wall thickening. Comparison with F-18 FDG-PET

    International Nuclear Information System (INIS)

    Maruyama, Atsushi; Hasegawa, Shinji; Paul, A.K.; Xiuli, M.; Yoshioka, Jun; Maruyama, Kaoru; Hori, Masatsugu; Nishimura, Tsunehiko

    2002-01-01

    This study was designed to assess the value of gated SPECT Tc-99m-tetrofosmin (TF) wall thickening (WT) in addition to TF exercise (Ex)/rest myocardial SPECT, in comparison with F-18 fluorodeoxyglucose (FDG)-PET. The study population consisted of 33 patients with old myocardial infarction (27 men and 6 women; mean age, 62±8 years old). All patients underwent Ex/rest TF SPECT and glucose loading FDG-PET. Polar map images of Ex/rest TF were generated and divided into 24 segments for further analysis. We classified LV segments according to the exercise-rest perfusion scintigraphy. LV segments with less than 70% of the maximum TF activity on the exercise image were defined as stress-induced defects. Among these, the segments whose TF acitvity increased by 10% from exercise to rest images or exceeded 70% of the maximum uptake were defined as reversible (viable) defects. The remaining defects on the rest image were irreversible (non-viable) defect segments, and were considered for viability study on the basis of %WT. %WT was calculated according to the standard method: {(counts ES-counts ED)/ counts ED} x 100. A viable segment on gated SPECT was defined as a segment whose %WT exceeded the lower limit of the normal value (mean-SD). PET viability was defined as FDG uptake exceeding 50% of the maximum count. Among the 792 segments evaluated in the 33 patients studied, there were 689 PET viable segments. Of the 689 segments analyzed, 198 (29%) were identified as having defects on Ex images. Among these defects, 55 (8%) were reversible or partially reversible, as evidenced by rest images, and 143 (21%) were irreversible. Of the irreversible segments on Ex/rest images, 106 (15%) demonstrated no apparent WT by gated TF SPECT, whereas 37 (6%) segments with irreversible defects did have apparent WT. Overall, the sensitivity of Ex/rest TF perfusion imaging was 79%. Sensitivity was improved from 79% to 85% by combining %WT and perfusion data, but specificity was reduced from 70

  12. Quantitation of myocardial blood flow and myocardial flow reserve with 99mTc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease

    International Nuclear Information System (INIS)

    Hsu, Bailing; Chen, Fu-Chung; Chen, Chien-Cheng; Wu, Tao-Cheng; Huang, Wen-Sheng; Hou, Po-Nien; Hung, Guang-Uei

    2014-01-01

    Conventional dual-head single photon emission computed tomography (SPECT)/CT systems capable of fast dynamic SPECT (DySPECT) imaging have a potential for flow quantitation. This study introduced a new method to quantify myocardial blood flow (MBF) and myocardial flow reserve (MFR) with DySPECT scan and evaluated the diagnostic performance of detecting coronary artery disease (CAD) compared with perfusion using invasive coronary angiography (CAG) as the reference standard. This study included 21 patients with suspected or known CAD who had received DySPECT, ECG-gated SPECT (GSPECT), and CAG (13 with ≥50 % stenosis in any vessel; non-CAD group: 8 with patent arteries or 99m Tc-sestamibi (MIBI) tracer at rest or dipyridamole-stress stages. DySPECT images were reconstructed with full physical corrections and converted to the physical unit of becquerels per milliliter. Stress MBF (SMBF), rest MBF (RMBF), and MFR were quantified by a one-tissue compartment flow model using time-activity curves derived from DySPECT images. Perfusion images were processed for GSPECT scan and interpreted to obtain summed stress score (SSS) and summed difference score (SDS). Receiver-operating characteristic (ROC) analyses were conducted to evaluate the diagnostic performance of flow and perfusion. Using the criteria of ≥50 % stenosis as positive CAD, areas under the ROC curve (AUCs) of flow assessment were overall significantly greater than those of perfusion. For patient-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.91 ± 0.07, 0.86 ± 0.09, 0.64 ± 0.12, and 0.59 ± 0.13. For vessel-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.81 ± 0.05, 0.76 ± 0.06, 0.62 ± 0.07, and 0.56 ± 0.08, respectively. The preliminary data suggest that MBF quantitation with a conventional SPECT/CT system and the flow quantitation method is a clinically effective approach to enhance CAD detection. (orig.)

  13. Determination of right ventricular ejection fraction from reprojected gated blood pool SPET: comparison with first-pass ventriculography

    International Nuclear Information System (INIS)

    Bartlett, M.L.; Seaton, D.; McEwan, L.; Fong, W.

    2001-01-01

    Gated blood pool (GBP) studies are widely available and relatively inexpensive. We have previously published a simple and convenient method for measuring left ventricle ejection fraction (EF) with increased accuracy from single-photon emission tomography (SPET) GBP scans. This paper describes an extension of this method by which right ventricular EF may also be measured. Gated SPET images of the blood pool are acquired and re-oriented in short-axis slices. Counts from the left ventricle are excluded from the short-axis slices, which are then reprojected to give horizontal long-axis images. Time-activity curves are generated from each pixel around the right ventricle, and an image is created with non-ventricular pixels ''greyed out''. This image is used as a guide in drawing regions of interest around the right ventricle on the end-diastolic and end-systolic long-axis images. In 28 patients, first-pass ventriculography studies were acquired followed by SPET GBP scans. The first-pass images were analysed a total of four times by two observers and the SPET images were analysed three times each by two observers. The agreement between the two techniques was good, with a correlation coefficient of 0.72 and a mean absolute difference between first-pass and reprojected SPET EFs of 4.8 EF units. Only four of the 28 patients had a difference of greater than 8 EF units. Variability was also excellent for SPET right ventricular EF values. Intra-observer variability was significantly lower for SPET than for first-pass EFs: standard error of the estimate (SEE)=5.1 and 7.3 EF units, respectively (P<0.05). Inter-observer variability was comparable in the two techniques (SEE=5.2 and 6.9 EF units for SPET and first-pass ventriculography, respectively). (orig.)

  14. sup 123 I-IMP SPECT study on patients with amnestic syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Hanyu, Haruo; Abe, Shinei; Arai, Hisayuki; Takasaki, Masaru; Suzuki, Takanari; Abe, Kimihiko; Amino, Saburo [Tokyo Medical Coll. (Japan)

    1992-06-01

    Regional cerebral blood flow was studied using single photon emission CT (SPECT) with {sup 123}I-IMP to elucidate the pathophysiology of amnesia. Four patients with amnestic syndrome diagnosed by DSM-III-R criteria were investigated. SPECT images demonstrated definite hypoperfusion of the temporoparietal lobe and relative sparing of motorsensory and occipital cortices in two out of four patients. Since these abnormalities of regional cerebral blood flow have been considered to be characteristic findings in dementia of the Alzheimer type, two patients with temporoparietal hypoperfusion are suggested to manifest the early stage of dementia of the Alzheimer type. Our observations suggest that {sup 123}I-IMP SPECT is an useful madality in the diagnosis of the early stage of dementia of the Alzheimer type, especially in patients with only memory impairment. (author).

  15. Comparison of benzodiazepine receptor SPECT and 18F-FDG PET using a coincidence detection camera in patients with temporal lobe epilepsy: preliminary results

    International Nuclear Information System (INIS)

    Wissmeyer, M.; Geiger, L.; Luescher, D.; Krause, T.; Loevblad, K.; Donati, F.; Wielepp, J.P.

    2002-01-01

    Full text: The aim of this preliminary study was to compare the results of benzodiazepine receptor (BDR) SPECT using 123 I-Iomazenil with those of 18 F-FDG (FDG) PET obtained on a double-headed gamma camera with a coincidence detection system in patients with temporal lobe epilepsy (TLE). We evaluated 6 patients (4 female, 2 male; age range 26-54 years, average 43.5 years) with therapy-refractory TLE due to mesiotemporal sclerosis or other focal brain anomalies. To delineate the epileptogenic zone, clinical evaluation, ictal and interictal surface EEG using the international 10-20 system, brain MRI, interictal CBF SPECT using 99m Tc-ECD, BDR SPECT and FDG coincidence PET were performed. The CBF SPECT, BDR SPECT and coincidence PET scans were viewed independently by 2 observers considering the regional cerebral blood flow, BDR density and FDG uptake asymmetry in the temporal lobe visually as none (0), low (1), moderate (2) and high (3). Ictal and interictal EEG recordings located the epileptogenic focus in all patients in the temporal region. Both the BDR SPECT and the FDG coincidence PET located the epileptogenic focus correctly in circumscribed areas of the temporal lobe in all patients, whereas brain MRI revealed focal anomalies only in 5 of 6 cases . The lateralization to the right (n=4) and left hemisphere (n=2) by interictal CBF SPECT, BDR SPECT and FDG coincidence PET corresponded to the EEG findings in all patients. The visual consideration of the asymmetry revealed a slightly but not statistically significant higher value for the FDG coincidence PET (observer 1: mean 2.333, SD 0.516; observer 2: mean 2.000, SD 0.632) than for the BDR SPECT (observer 1: mean 1.667, SD 1.033; observer 2: mean 1.833, SD 0.753). Visual consideration of the interictal CBF SPECT revealed mean values of 2.000 for both observers. The inter-observer variability was higher in the BDR SPECT than in the FDG coincidence PET and the interictal CBF SPECT, but the difference was not

  16. Brain regions associated with cognitive impairment in patients with Parkinson disease: quantitative analysis of cerebral blood flow using 123I iodoamphetamine SPECT.

    Science.gov (United States)

    Hattori, Naoya; Yabe, Ichiro; Hirata, Kenji; Shiga, Tohru; Sakushima, Ken; Tsuji-Akimoto, Sachiko; Sasaki, Hidenao; Tamaki, Nagara

    2013-05-01

    Cognitive impairment is a representative neuropsychiatric presentation that accompanies Parkinson disease (PD). The purpose of this study was to localize the cerebral regions associated with cognitive impairment in patients with PD using quantitative SPECT. Thirty-two patients with PD (mean [SD] age, 75 [8] years; 25 women; Hoehn-Yahr scores from 2 to 5) underwent quantitative brain SPECT using 123I iodoamphetamine. Parametric images of regional cerebral blood flow (rCBF) were spatially normalized to the standard brain atlas. First, voxel-by-voxel comparison between patients with PD with versus without cognitive impairment was performed to visualize overall trend of regional differences. Next, the individual quantitative rCBF values were extracted in representative cortical regions using a standard region-of-interest template to compare the quantitative rCBF values. Patients with cognitive impairment showed trends of lower rCBF in the left frontal and temporal cortices as well as in the bilateral medial frontal and anterior cingulate cortices in the voxel-by-voxel analyses. Region-of-interest-based analysis demonstrated significantly lower rCBF in the bilateral anterior cingulate cortices (right, 25.8 [5.5] vs 28.9 [5.7] mL per 100 g/min, P left, 25.8 [5.8] vs 29.1 [5.7] mL per 100 g/min, P left frontal and temporal cortices as well as in the bilateral medial frontal and anterior cingulate cortices. The results suggested dysexecutive function as an underlining mechanism of cognitive impairment in patients with PD.

  17. Sensitivity of nested-PCR for plasmodium detection in pooled whole blood samples and its usefulness to blood donor screening in endemic areas.

    Science.gov (United States)

    de Freitas, Daniel Roberto Coradi; Gomes, Luciano Teixeira; Fontes, Cor Jesus F; Tauil, Pedro Luiz; Pang, Lorrin W; Duarte, Elisabeth Carmen

    2014-04-01

    Transfusion-transmitted malaria is a severe disease with high fatality rate. Most Brazilian blood banks in the Amazon region perform malaria screening using microscopic examination (thick smears). Since low parasite concentrations are expected in asymptomatic blood donors a high sensitivity test should be used for donor screening. This study determined the sensitivity of a nested-PCR for plasmodium detection in pooled samples. We performed a one-stage criterion validation study with 21 positive samples pooled with samples from ten negative volunteer until three different concentrations were reached (0.33; 0.25; 0.20 parasites/μL - p/μL). Nested PCR was performed as described by Snounou et al. (1993). Sensitivities (and confidence intervals) were determined by stratum of final parasite concentration on the pooled samples. All samples with parasitemia values of 0.33 and 0.25 p/μL had 100% sensitivity (95%CI=86.3-100). One negative result was obtained from a sample with 0.20 p/μL sensitivity=95.2% (95%CI=76.2-99.9). Compared to parasitemia detectable under ideal conditions of thick smear, this nested-PCR in pooled sample was able to detect 40 times more parasites per microliter. Nested-PCR in pooled samples should be considered as a high sensitive alternative to thick smear for donor screening in blood banks at endemic regions. Local authorities need to assess cost:benefit advantages of this method compared to alternatives. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. SPECT and PET in Eating Disorders

    NARCIS (Netherlands)

    van Waarde, Aren; Audenaert, Kurt; Busatto, Geraldo F.; Buchpiguel, Carlos; Dierckx, Rudi; Dierckx, Rudi AJO; Otte, Andreas; de Vries, Erik FJ; van Waarde, Aren; den Boer, Johan A

    2014-01-01

    Medical imaging techniques like PET and SPECT have been applied for investigation of brain function in anorexia and bulimia nervosa. Regional abnormalities have been detected in cerebral blood flow, glucose metabolism, the availability of several neurotransmitter receptors (serotonin 1A and 2A,

  19. Brain SPECT with Tl-201 DDC

    International Nuclear Information System (INIS)

    Bruine, J.F. de.

    1988-01-01

    The development, animal and human experiments and the first clinical results of a new blood flow tracer thallium-201 diethyldithiocarbamate (Tl-201 DDC) are discussed for functional brain imaging with single-photon emission computed tomography (SPECT). 325 refs.; 43 figs.; 22 tabs

  20. Study on 99Tcm-DTPA-HSA as a new blood pool scanning agent

    International Nuclear Information System (INIS)

    Liu Yunzhong; Zhang Zheng; Wu Qingwen

    1994-01-01

    The biological behavior of 99 Tc m -DTPA-HSA, 99 Tc m -RBC(in vivo) and 99 Tc m -HSA are studied in rabbits. Excellent cardiac blood-pool images are obtained by 99 Tc m -DTPT-HSA and 99 Tc m -RBC. Biodistribution studies show that 99 Tc m -DTPA-HSA has less accumulation than 99 Tc m -RBC in lungs and liver. They have similar count ratio of the cardiac blood pool to whole body. Ratio of heart/liver is 0.85 for 99 Tc m -DTPA-HSA, 0.95 for 99 Tc m -RBC and 0.62 for 99 Tc m -HSA. 99 Tc m -DTPA-HSA is a promising agent. It is readily performed only by single in vivo injection

  1. Detection of soft tissue pathology on the blood pool phase of bone scans

    International Nuclear Information System (INIS)

    Raimondo, A.J.; Turner, H.A.; Kitchener, M.I.

    1999-01-01

    Full text: It is important to optimize information obtained from isotope bone scanning in musculoskeletal imaging. Although important at all times, it is especially imperative in the current climate of health services rationalization, capping of imaging expenditure and the promotion of newer modalities that are increasingly versatile and sensitive for imaging the musculoskeletal system. Careful attention must be paid to the blood flow and blood pool images, to visualize soft tissue as well as bony pathology. A series of cases and images will be presented that demonstrated blood pool pathology that was not appreciated on delayed imaging, or where reliance only on the delayed images would have led to an incorrect diagnosis. These include the detection of tendonitis, tenosynovitis, bursitis, muscle tears and soft tissue neoplasms, including neuromas. In cases where the bone scan cannot provide a definitive diagnosis, it will at least direct the referring clinician to the most appropriate confirmatory diagnostic imaging modality, thus reinforcing the value that isotope imaging provides in musculoskeletal medicine

  2. A methodology for generating normal and pathological brain perfusion SPECT images for evaluation of MRI/SPECT fusion methods: application in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Grova, C [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Jannin, P [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Biraben, A [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Buvat, I [INSERM U494, CHU Pitie Salpetriere, Paris (France); Benali, H [INSERM U494, CHU Pitie Salpetriere, Paris (France); Bernard, A M [Service de Medecine Nucleaire, Centre Eugene Marquis, Rennes (France); Scarabin, J M [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Gibaud, B [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France)

    2003-12-21

    Quantitative evaluation of brain MRI/SPECT fusion methods for normal and in particular pathological datasets is difficult, due to the frequent lack of relevant ground truth. We propose a methodology to generate MRI and SPECT datasets dedicated to the evaluation of MRI/SPECT fusion methods and illustrate the method when dealing with ictal SPECT. The method consists in generating normal or pathological SPECT data perfectly aligned with a high-resolution 3D T1-weighted MRI using realistic Monte Carlo simulations that closely reproduce the response of a SPECT imaging system. Anatomical input data for the SPECT simulations are obtained from this 3D T1-weighted MRI, while functional input data result from an inter-individual analysis of anatomically standardized SPECT data. The method makes it possible to control the 'brain perfusion' function by proposing a theoretical model of brain perfusion from measurements performed on real SPECT images. Our method provides an absolute gold standard for assessing MRI/SPECT registration method accuracy since, by construction, the SPECT data are perfectly registered with the MRI data. The proposed methodology has been applied to create a theoretical model of normal brain perfusion and ictal brain perfusion characteristic of mesial temporal lobe epilepsy. To approach realistic and unbiased perfusion models, real SPECT data were corrected for uniform attenuation, scatter and partial volume effect. An anatomic standardization was used to account for anatomic variability between subjects. Realistic simulations of normal and ictal SPECT deduced from these perfusion models are presented. The comparison of real and simulated SPECT images showed relative differences in regional activity concentration of less than 20% in most anatomical structures, for both normal and ictal data, suggesting realistic models of perfusion distributions for evaluation purposes. Inter-hemispheric asymmetry coefficients measured on simulated data were

  3. Interictal brain SPECT in patients with medically refractory temporal lobe epilepsy; SPECT cerebral interictal em pacientes com epilepsia do lobo temporal de dificil controle

    Energy Technology Data Exchange (ETDEWEB)

    Andraus, Maria Emilia Cosenza

    2000-06-01

    The brain single photon emission computed tomography (SPECT) is s functional neuroimaging method that can detect localized changes in cerebral blood flow. The temporal lobe epilepsy (TLE) is the most common epileptic syndrome in adults, and more than 50% are medically refractory. The SPECT can contribute to investigation of epileptogenic focus and is one of the methods of pre-surgical evaluation of these patients. (author)

  4. Is SPECT useful in imaging of abdominal inflammatory processes using 99mTc-HMPAO-WBCs?

    International Nuclear Information System (INIS)

    Smole, M.S.; Stantic, T.S.; Fettich, J.F.

    2002-01-01

    Aim: The aim of the study is to determine whether SPECT gives additional information in the assessment of inflammation of the abdominal region with labelled white blood cells as compared with usual planar imaging. Patients And Methods: SPECT and planar imaging was performed in 26 patients with suspected inflammatory process in the abdomen, within three hours after injection of autologous white blood cells labelled with 99m Tc HMPAO. Planar images where acquired as static spot images using high resolution low energy collimator on 256 x 256 matrix. SPECT was performed using the same collimator on 128 x 128 matrix in 128 projections. Filtered back projection was used for reconstruction and volume rendering was performed. Results: The lesions in the abdomen were classified as jejunum, colon ascendents, colon transversum, colon descendents, sigmoid, and lesions outside GIT. All lesions, which were seen on planar images, except one, were also seen on SPECT. Five equivocal lesions seen on planar images were reconfirmed as pathological on SPECT. Additionally SPECT revealed three lesions not seen on planar images. Fourteen lesions were seen by both imaging techniques. All together SPECT improved diagnostic accuracy of 99m Tc - HMPAO - WBC scintigraphy in 7/28 patients. Conclusion: more inflammatory lesions in the abdomen are revealed by SPECT and volume rendering, than by planar imaging equivocal lesions seen on planar images can be characterised as positive or negative by SPECT. SPECT artefacts can cause possible false positive results; therefore usual planar imaging cannot be omitted if SPECT is performed

  5. PET and SPECT of neurobiological systems

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [Groningen Univ. (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Gent Univ. (Belgium). Dept. of Nuclear Medicine; Otte, Andreas [Univ. of Applied Sciences, Offenburg (Germany). Faculty of Electrical Engineering and Information Technology; Vries, Erik F.J. de; Waarde, Aren van (eds.) [Groningen Univ. (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging

    2014-04-01

    Addresses a variety of aspects of neurotransmission in the brain. Details the latest results in probe development. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT of Neurobiological Systems combines the expertise of renowned authors whose dedication to the development of novel probes and techniques for the investigation of neurobiological systems has achieved international recognition. Various aspects of neurotransmission in the brain are discussed, such as visualization and quantification of (more than 20 different) neuroreceptors, neuroinflammatory markers, transporters, and enzymes as well as neurotransmitter synthesis, ?-amyloid deposition, cerebral blood flow, and the metabolic rate of glucose. The latest results in probe development are also detailed. Most chapters are written jointly by radiochemists and nuclear medicine specialists to ensure a multidisciplinary approach. This state of the art compendium will be valuable to anyone in the field of clinical or preclinical neuroscience, from the radiochemist and radiologist/nuclear medicine specialist to the interested neurobiologist and general practitioner. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences. Other volumes focus on PET and SPECT in psychiatry and PET and SPECT in neurology''.

  6. A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT.

    Science.gov (United States)

    Sciammarella, Maria; Shrestha, Uttam M; Seo, Youngho; Gullberg, Grant T; Botvinick, Elias H

    2017-08-03

    SPECT myocardial perfusion imaging (MPI) is a clinical mainstay that is typically performed with static imaging protocols and visually or semi-quantitatively assessed for perfusion defects based upon the relative intensity of myocardial regions. Dynamic cardiac SPECT presents a new imaging technique based on time-varying information of radiotracer distribution, which permits the evaluation of regional myocardial blood flow (MBF) and coronary flow reserve (CFR). In this work, a preliminary feasibility study was conducted in a small patient sample designed to implement a unique combined static-dynamic single-dose one-day visit imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT for improving the diagnosis of coronary artery disease (CAD). Fifteen patients (11 males, four females, mean age 71 ± 9 years) were enrolled for a combined dynamic and static SPECT (Infinia Hawkeye 4, GE Healthcare) imaging protocol with a single dose of 99m Tc-tetrofosmin administered at rest and a single dose administered at stress in a one-day visit. Out of 15 patients, eleven had selective coronary angiography (SCA), 8 within 6 months and the rest within 24 months of SPECT imaging, without intervening symptoms or interventions. The extent and severity of perfusion defects in each myocardial region was graded visually. Dynamically acquired data were also used to estimate the MBF and CFR. Both visually graded images and estimated CFR were tested against SCA as a reference to evaluate the validity of the methods. Overall, conventional static SPECT was normal in ten patients and abnormal in five patients, dynamic SPECT was normal in 12 patients and abnormal in three patients, and CFR from dynamic SPECT was normal in nine patients and abnormal in six patients. Among those 11 patients with SCA, conventional SPECT was normal in 5, 3 with documented CAD on SCA with an overall accuracy of 64%, sensitivity of 40% and specificity of 83%. Dynamic SPECT image

  7. IQ-SPECT for thallium-201 myocardial perfusion imaging: effect of normal databases on quantification.

    Science.gov (United States)

    Konishi, Takahiro; Nakajima, Kenichi; Okuda, Koichi; Yoneyama, Hiroto; Matsuo, Shinro; Shibutani, Takayuki; Onoguchi, Masahisa; Kinuya, Seigo

    2017-07-01

    Although IQ-single-photon emission computed tomography (SPECT) provides rapid acquisition and attenuation-corrected images, the unique technology may create characteristic distribution different from the conventional imaging. This study aimed to compare the diagnostic performance of IQ-SPECT using Japanese normal databases (NDBs) with that of the conventional SPECT for thallium-201 ( 201 Tl) myocardial perfusion imaging (MPI). A total of 36 patients underwent 1-day 201 Tl adenosine stress-rest MPI. Images were acquired with IQ-SPECT at approximately one-quarter of the standard time of conventional SPECT. Projection data acquired with the IQ-SPECT system were reconstructed via an ordered subset conjugate gradient minimizer method with or without scatter and attenuation correction (SCAC). Projection data obtained using the conventional SPECT were reconstructed via a filtered back projection method without SCAC. The summed stress score (SSS) was calculated using NDBs created by the Japanese Society of Nuclear Medicine working group, and scores were compared between IQ-SPECT and conventional SPECT using the acquisition condition-matched NDBs. The diagnostic performance of the methods for the detection of coronary artery disease was also compared. SSSs were 6.6 ± 8.2 for the conventional SPECT, 6.6 ± 9.4 for IQ-SPECT without SCAC, and 6.5 ± 9.7 for IQ-SPECT with SCAC (p = n.s. for each comparison). The SSS showed a strong positive correlation between conventional SPECT and IQ-SPECT (r = 0.921 and p IQ-SPECT with and without SCAC was also good (r = 0.907 and p IQ-SPECT without SCAC; and 88.5, 86.8, and 87.3%, respectively, for IQ-SPECT with SCAC, respectively. The area under the curve obtained via receiver operating characteristic analysis were 0.77, 0.80, and 0.86 for conventional SPECT, IQ-SPECT without SCAC, and IQ-SPECT with SCAC, respectively (p = n.s. for each comparison). When appropriate NDBs were used, the diagnostic performance of 201 Tl IQ-SPECT

  8. Findings of 99mTc-HMPAO Regional Cerebral Blood Flow SPECT in a Case of Herpes Simplex Encephalitis

    International Nuclear Information System (INIS)

    Ahn, Myeong Im; Lee, Sung Yong; Kim, Jong Woo; Bahk, Yong Whee

    1989-01-01

    Herpes simplex encephalitis (HSE) is one of the fulminant necrotizing, often fatal sporadic form of the encephalitis caused by herpes simplex type I virus. Characteristically, there is early and almost constant involvement of one or both temporal lobes, although there are common additional areas of involvement. Appropriate early treatment following correct diagnosis by clinical findings, CSF study, EEG and several radiological studies including angiography, radionuclide studies, CT or MRI can reduce its mortality and severity of the sequelae. We report a case of HSE diagnosed by adjuvant study of 99m Tc-HMPAO regional cerebral blood flow SPECT, which showed a marked increase in bitemporal cerebral blood flow in a 24-year-old man.

  9. SPECT determination of regional cerebral blood flow in hypertensive patients before and after clonidine

    International Nuclear Information System (INIS)

    Devous, M.D.; Reed, W.G.; Chehabi, H.H.; Bonte, F.J.

    1985-01-01

    Regional cerebral blood flow (rCBF) was determined by SPECT of 133-Xe inert gas washout in 18 hypertensive patients (PTS) upon admission and after treatment with oral clonidine (CL, 0.2 mg, then 0.1 mg/hr until diastolic pressure reached 105 mm Hg or fell by 30 mm Hg). CL reduced mean arterial pressure (MAP) from 160 (200/140) to 133 (150/100) mm Hg over 4-6 hr. RCBF was quantitated in 14 gray matter regions from cross-sectional images and analyzed for differences from normal controls and changes with CL. Initial rCBF was lower in HI PTS than in either normal controls of LO PTS in all brain regions. CL lowered MAP in HI PTS by 52 +- 15 mm Hg and caused reduction in all gray matter regions except right frontal and right temporal (mean reduction 5 +- 2 ml/min/100 g, rho<.05). RCBF images were also evaluated by two trained observers for initial regional defects and for changes with CL. LO PTS were more likely to have defects in rCBF images at rest which would resolve with CL. HI PTS frequently had normal images at rest and developed defects with CL. In summary, the study suggests that SPECT may be useful in detecting rCBF abnormalities in hypertensive PTS at rest and following reductions in MAP

  10. Effect of attenuation by the cranium on quantitative SPECT measurements of cerebral blood flow and a correction method

    International Nuclear Information System (INIS)

    Iwase, Mikio; Kurono, Kenji; Iida, Akihiko.

    1998-01-01

    Attenuation correction for cerebral blood flow SPECT image reconstruction is usually performed by considering the head as a whole to be equivalent to water, and the effects of differences in attenuation between subjects produced by the cranium have not been taken into account. We determined the differences in attenuation between subjects and assessed a method of correcting quantitative cerebral blood flow values. Attenuations by head on the right and left sides were measured before intravenous injection of 123 I-IMP, and water-converted diameters of both sides (Ta) were calculated from the measurements obtained. After acquiring SPECT images, attenuation correction was conducted according to the method of Sorenson, and images were reconstructed. The diameters of the right and left sides in the same position as the Ta (Tt) were calculated from the contours determined by threshold values. Using Ts given by 2 Ts=Ta-Tt, the correction factor λ=exp(μ 1 Ts) was calculated and multiplied as the correction factor when rCBF was determined. The results revealed significant differences between Tt and Ta. Although no gender differences were observed in Tt, they were seen in both Ta and Ts. Thus, interindividual differences in attenuation by the cranium were found to have an influence that cannot be ignored. Inter-subject correlation is needed to obtain accurate quantitative values. (author)

  11. Quantitative assessment of 201TlCl myocardial SPECT

    International Nuclear Information System (INIS)

    Uehara, Toshiisa

    1987-01-01

    Clinical evaluation of the quantitative analysis of Tl-201 myocardial tomography by SPECT (Single Photon Emission Computed Tomography) was performed in comparison with visual evaluation. The method of quantitative analysis has been already reported in our previous paper. In this study, the program of re-standardization in the case of lateral myocardial infarction was added. This program was useful mainly for the evaluation of lesions in the left circumflex coronary artery. Regarding the degree of diagnostic accuracy of myocardial infarction in general, quantitative evaluation of myocardial SPECT images was highest followed by visual evaluation of myocardial SPECT images, and visual evaluation of myocardial planar images. However, in the case of anterior myocardial infarction, visual evaluation of myocardial SPECT images has almost the same detectability as quantitative evaluation of myocardial SPECT images. In the case of infero-posterior myocardial infarction, quantitative evaluation was superior to visual evaluation. As for specificity, quantitative evaluation of SPECT images was slightly inferior to visual evaluation of SPECT images. An infarction map was made by quantitative analysis and this enabled us to determine the infarction site, extent and degree according to easily recognizable patterns. As a result, the responsible coronary artery lesion could be inferred correctly and the calculated infarction score could be correlated with the residual left ventricular function after myocardial infarction. (author)

  12. Regional cerebral blood flow assessed by single photon emission computed tomography (SPECT) in dogs with congenital portosystemic shunt and hepatic encephalopathy.

    Science.gov (United States)

    Or, Matan; Peremans, Kathelijne; Martlé, Valentine; Vandermeulen, Eva; Bosmans, Tim; Devriendt, Nausikaa; de Rooster, Hilde

    2017-02-01

    Regional cerebral blood flow (rCBF) in eight dogs with congenital portosystemic shunt (PSS) and hepatic encephalopathy (HE) was compared with rCBF in eight healthy control dogs using single photon emission computed tomography (SPECT) with a 99m technetium-hexamethylpropylene amine oxime ( 99m Tc-HMPAO) tracer. SPECT scans were abnormal in all PSS dogs. Compared to the control group, rCBF in PSS dogs was significantly decreased in the temporal lobes and increased in the subcortical (thalamic and striatal) area. Brain perfusion imaging alterations observed in the dogs with PSS and HE are similar to those in human patients with HE. These findings suggest that dogs with HE and PSS have altered perfusion of mainly the subcortical and the temporal regions of the brain. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Hepatic hemangioma. Comparison between MR and SPECT in its detection and characterization

    International Nuclear Information System (INIS)

    Galant Herrero, J.; Marti-Bonmati, L.; Sopena Monforte, R.; Caballero Calabuig, E.; Martinez Rodrigo, J.; Ferrer Puchol, D.; Paniagua Escudero, J.C.

    1993-01-01

    Given the high prevalence of hepatic hemangioma, diagnostic techniques that differentiate these benign lesions from metastasis, hepatoma, and other malignant diseases are necessary. Twenty-five consecutive patients in whom ultrasonography led to the suspicion of hemangioma were studied by magnetic resonance (MR) and tomographic scintigraphy using 99m Tc-labeled red blood cells. Twenty patients presented 42 hemangiomas. Of the 5 remaining patients, 2 proved to have hepatoma and 3 had metastases. Both MR and SPECT have been shown to be highly sensitive in the diagnosis of hepatic hemangioma (95% and 74%, respectively). The specificity of both techniques was 100%. A diagnostic algorithm is presented, based on the high sensitivity and specificity of the two techniques for the purpose of avoiding unnecessary diagnostic measures. (Author)

  14. Alterations of the blood pool in the femoral head before and after renal transplantation

    International Nuclear Information System (INIS)

    Hamaguchi, Hiroyuki; Fujioka, Mikihiro; Inoue, Shigehiro; Shibatani, Masahiko; Kubo, Toshikazu; Kubota, Takao; Ushijima, Yo; Nishimura, Tsunehiko

    2003-01-01

    The pathogenesis of idiopathic osteonecrosis of the femoral head (ION) is thought to be an ischemic event. The purpose of this study is to investigate alterations of the blood pool in the femoral head before and after renal transplantation. After renal transplantation, all patients received the same immunosuppressive therapy: corticosteroids, cyclosporin-A, and azathioprine. We performed 3-phase bone scintigraphy on 16 renal allograft recipients within 1 week before renal transplantation, and between week 4 and 9 after renal transplantation. Regions of interest (ROI) were assigned bilaterally in the femoral head, diaphysis, and soft tissue. The head-to-diaphysis ratios (HD ratios) were then calculated. Idiopathic osteonecrosis of the femoral head occurred in 2 femoral heads of 1 patient. The HD ratio before renal transplantation (mean HD±SD, 1.52±0.30) and the HD ratio after renal transplantation (1.28±0.30) were significantly different (P=0.000024). The HD ratios before and after renal transplantation were significantly different, indicating that the administration of steroids diminished the blood pool in the femoral head. A low HD ratio before renal transplantation revealed a poor blood pool in the femoral head, which may be a risk factor for ION. (author)

  15. Assessment of effective dose from cone beam CT imaging in SPECT/CT examination in comparison with other modalities

    International Nuclear Information System (INIS)

    Tonkopi, Elena; Ross, Andrew A.

    2016-01-01

    The aim of this study was to assess radiation dose from the cone beam computed tomography (CBCT) component of single photon emission tomography/computed tomography (SPECT/CT) examinations and to compare it with the radiopharmaceutical related dose as well as dose from multidetector computed tomography (MDCT). Effective dose (ED) from computed tomography (CT) was estimated using dose-length product values and anatomy-specific conversion factors. The contribution from the SPECT component was evaluated using ED per unit administered activity for the radiopharmaceuticals listed in the International Commission on Radiological Protection Publications 80 and 106. With the exception of cardiac studies (0.11 mSv), the CBCT dose (3.96-6.04 mSv) was similar to that from the radiopharmaceutical accounting for 29-56 % of the total ED from the examination. In comparison with MDCT examinations, the CBCT dose was 48 and 42 % lower for abdomen/pelvis and chest/abdomen/pelvis scans, respectively, while in the chest the CBCT scan resulted in higher dose (23 %). Radiation dose from the CT component should be taken into consideration when evaluating total SPECT/CT patient dose. (authors)

  16. Clinical application of SPECT and PET in cerebrovascular disease

    International Nuclear Information System (INIS)

    Ra, Young Shin

    2003-01-01

    Single photon emission computed tomography(SPECT) and positron emission tomography(PET) are modern imaging techniques that allow for both qualitative are quantitative assessment of hemodynamic changes in cerebrovascular diseases. SPECT has been becoming an indispensable method to investigate regional cerebral blood flow because equipment and isotope are easily available in most general hospitals. Acetazolamide stress SPECT has also been proved to be useful to evaluate the cerebrovascular reserve of occlusive cerebrovascular diseases and to select surgical candidate. PET has gained wide spread clinical use in the evaluation of the hemodynamic and metabolic consequences of extracranial or intracranial arterial obstructive disease despite its complexity and limited availability. PET has been established as an invaluable tool in the pathophysilogy investigation of acute ischemic stroke. The potentials, limitations, and clinical applications of SPECT and PET in various cerebrovascular diseases will be discussed in this article with reviews of literatures

  17. Clinical application of SPECT and PET in cerebrovascular disease

    Energy Technology Data Exchange (ETDEWEB)

    Ra, Young Shin [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2003-02-01

    Single photon emission computed tomography(SPECT) and positron emission tomography(PET) are modern imaging techniques that allow for both qualitative are quantitative assessment of hemodynamic changes in cerebrovascular diseases. SPECT has been becoming an indispensable method to investigate regional cerebral blood flow because equipment and isotope are easily available in most general hospitals. Acetazolamide stress SPECT has also been proved to be useful to evaluate the cerebrovascular reserve of occlusive cerebrovascular diseases and to select surgical candidate. PET has gained wide spread clinical use in the evaluation of the hemodynamic and metabolic consequences of extracranial or intracranial arterial obstructive disease despite its complexity and limited availability. PET has been established as an invaluable tool in the pathophysilogy investigation of acute ischemic stroke. The potentials, limitations, and clinical applications of SPECT and PET in various cerebrovascular diseases will be discussed in this article with reviews of literatures.

  18. Assessment of early radiation effects on the liver. Comparison of SPECT and MR

    International Nuclear Information System (INIS)

    Masui, T.

    1996-01-01

    Purpose: To evaluate the early effects of radiation on the liver using single photon emission CT (SPECT) with 99m Tc-phytate combined with a pinhole collimator and MR imaging with superparamagnetic iron oxide (SPIO) and to compare 2 modalities regarding the assessment of the reticuloendothelial cell function. Material and Methods: The right sides of the livers of 12 anesthetized rats were irradiated with X-rays (4000 Cgy). On the 3rd and 4th days postirradiation, SPECT and MR imaging pre- and postcontrast were performed. Results: On SPECT, the irradiated areas appeared as areas with reduced 99m Tc-phytate uptake in 9 rats. In the remaining 3 rats, irradiated lesions were not evident on SPECT. On the early postcontrast MR images, differential negative enhancement of the irradiated and nonirradiated areas in the same 9 rats as on SPECT was apparent. However, on the later postcontrast images of 3 of these rats, the irradiated areas, which were brighter than the nonirradiated areas, were visually less clear than those on the earlier postcontrast images. In the remaining 3 rats, no radiation damag was evident on MR images. Conclusion: SPECT with 99m Tc-phytate and early postcontrast MR imaging with SPIO can show early radiation damage of the liver. The serial assessment of the postcontrast MR images provides functional information on the Kupffer cells. (orig.)

  19. Technetium-99m-HMPAO SPECT in the evaluation of patients with a remote history of traumatic brain injury: a comparison with x-ray computed tomography.

    Science.gov (United States)

    Gray, B G; Ichise, M; Chung, D G; Kirsh, J C; Franks, W

    1992-01-01

    The functional imaging modality has potential for demonstrating parenchymal abnormalities not detectable by traditional morphological imaging. Fifty-three patients with a remote history of traumatic brain injury (TBI) were studied with SPECT using 99mTc-hexamethylpropyleneamineoxime (HMPAO) and x-ray computed tomography (CT). Overall, 42 patients (80%) showed regional cerebral blood flow (rCBF) deficits by HMPAO SPECT, whereas 29 patients (55%) showed morphological abnormalities by CT. Out of 20 patients with minor head injury, 12 patients (60%) showed rCBF deficits and 5 patients (25%) showed CT abnormalities. Of 33 patients with major head injury, 30 patients (90%) showed rCBF deficits and 24 patients (72%) showed CT abnormalities. Thus, HMPAO SPECT was more sensitive than CT in detecting abnormalities in patients with a history of TBI, particularly in the minor head injury group. In the major head injury group, three patients showed localized cortical atrophy by CT and normal rCBF by HMPAO SPECT. In the evaluation of TBI patients, HMPAO SPECT is a useful technique to demonstrate regional brain dysfunction in the presence of morphological integrity as assessed by CT.

  20. The role of SPECT/CT in radioembolization of liver tumours

    Energy Technology Data Exchange (ETDEWEB)

    Ahmadzadehfar, Hojjat [University Hospital Bonn, Department of Nuclear Medicine, Bonn (Germany); Duan, Heying; Haug, Alexander R.; Hoffmann, Martha [Medical University of Vienna, Department of Biomedical Imaging und Image-guided Therapy, Clinical Division of Nuclear Medicine, Vienna (Austria); Walrand, Stephan [Universite Catholique de Louvain, Nuclear Medicine, Brussels (Belgium)

    2014-05-15

    Radioembolization (RE) with {sup 90}Y microspheres is a promising catheter-based therapeutic option for patients with unresectable primary and metastatic liver tumours. Its rationale arises from the dual blood supply of liver tissue through the hepatic artery and the portal vein. Metastatic hepatic tumours measuring >3 mm derive 80 - 100 % of their blood supply from the arterial rather than the portal hepatic circulation. Typically, an angiographic evaluation combined with {sup 99m}Tc-macroaggregated albumin ({sup 99m}Tc-MAA) scan precedes therapy to map the tumour feeding vessels as well as to avoid the inadvertent deposition of microspheres in organs other than the liver. Prior to administration of {sup 99m}Tc-MAA, prophylactic coil embolization of the gastroduodenal artery is recommended to avoid extrahepatic deposition of the microspheres. SPECT/CT allows direct correlation of anatomic and functional information in patients with unresectable liver disease. SPECT/CT is recommended to assess intrahepatic distribution as well as extrahepatic gastrointestinal uptake in these patients. Pretherapeutic SPECT/CT is an important component of treatment planning including catheter positioning and dose finding. A post-therapy bremsstrahlung (BS) scan should follow RE to verify the distribution of the administered tracer. BS SPECT/CT imaging enables better localization and definition of intrahepatic and possible extrahepatic sphere distribution and to a certain degree allows posttreatment dosimetry. In this paper we address the usefulness and significance of SPECT/CT in therapy planning and therapy monitoring of RE. (orig.)

  1. Diagnosis of regional cerebral blood flow abnormalities using SPECT: agreement between individualized statistical parametric maps and visual inspection by nuclear medicine physicians with different levels of expertise in nuclear neurology

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Euclides Timoteo da, E-mail: euclidestimoteo@uol.com.b [Fundacao Pio XII, Barretos, SP (Brazil). Hospital de Cancer. Dept. de Medicina Nuclear; Buchpiguel, Carlos Alberto [Hospital do Coracao, Sao Paulo, SP (Brazil). Dept. de Medicina Nuclear; Nitrini, Ricardo [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Dept. de Neurologia; Tazima, Sergio [Hospital Alemao Oswaldo Cruz (HAOC), Sao Paulo, SP (Brazil). Dept. de Medicina Nuclear; Peres, Stela Verzinhase [Fundacao Pio XII, Barretos, SP (Brazil). Hospital de Cancer; Busatto Filho, Geraldo [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Div. de Medicina Nuclear

    2009-07-01

    Introduction: visual analysis is widely used to interpret regional cerebral blood flow (rCBF) SPECT images in clinical practice despite its limitations. Automated methods are employed to investigate between-group rCBF differences in research studies but have rarely been explored in individual analyses. Objectives: to compare visual inspection by nuclear physicians with the automated statistical parametric mapping program using a SPECT dataset of patients with neurological disorders and normal control images. Methods: using statistical parametric mapping, 14 SPECT images from patients with various neurological disorders were compared individually with a databank of 32 normal images using a statistical threshold of p<0.05 (corrected for multiple comparisons at the level of individual voxels or clusters). Statistical parametric mapping results were compared with visual analyses by a nuclear physician highly experienced in neurology (A) as well as a nuclear physician with a general background of experience (B) who independently classified images as normal or altered, and determined the location of changes and the severity. Results: of the 32 images of the normal databank, 4 generated maps showing rCBF abnormalities (p<0.05, corrected). Among the 14 images from patients with neurological disorders, 13 showed rCBF alterations. Statistical parametric mapping and physician A completely agreed on 84.37% and 64.28% of cases from the normal databank and neurological disorders, respectively. The agreement between statistical parametric mapping and ratings of physician B were lower (71.18% and 35.71%, respectively). Conclusion: statistical parametric mapping replicated the findings described by the more experienced nuclear physician. This finding suggests that automated methods for individually analyzing rCBF SPECT images may be a valuable resource to complement visual inspection in clinical practice. (author)

  2. Follow-up of pain processing recovery after ketamine in hyperalgesic fibromyalgia patients using brain perfusion ECD-SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Guedj, Eric; Cammilleri, Serge; Colavolpe, Cecile; Laforte, Catherine de; Mundler, Olivier [Assistance Publique des Hopitaux de Marseille, Centre Hospitalo-Universitaire de la Timone, Service Central de Biophysique et de Medecine Nucleaire, Marseille, Cedex 5 (France); Niboyet, Jean [Clinique La Phoceanne, Unite d' Etude et de Traitement de la Douleur, Marseille (France)

    2007-12-15

    The aim of this study was to determine whether the follow-up of pain processing recovery in hyperalgesic fibromyalgia (FM) could be objectively evaluated with brain perfusion ethyl cysteinate dimer single photon computerized tomography (ECD-SPECT) after administration of ketamine. We enrolled 17 hyperalgesic FM women patients (48.5 {+-} 11 years, range 25-63). After treatment with subcutaneous ketamine, 11 patients were considered as 'good responders', with a decrease in pain intensity, evaluated by visual analog scale (VAS), greater than 50%. On the other hand, six patients were considered as 'poor responders'. A voxel-based analysis of regional cerebral blood flow (rCBF) was conducted (p{sub voxel} < 0.001uc), in the two subgroups of patients, before and after treatment, in comparison to a group of ten healthy subjects, matched for age and gender. In comparison to baseline brain SPECT, midbrain rCBF showed a greater increase after ketamine in the responder group than in the nonresponder group (p{sub cluster} = 0.016c). In agreement with the clinical response, the change in midbrain rCBF after ketamine was highly correlated with the reduction of VAS pain score (r = 0.7182; p = 0.0041). This prospective study suggests that blockade of facilitatory descending modulation of pain with ketamine can be evaluated in the periaqueductal grey with brain perfusion SPECT. (orig.)

  3. Asymmetry of cerebral blood flow in patients with senile dementia of Alzheimer type by SPECT using I-123 IMP

    Energy Technology Data Exchange (ETDEWEB)

    Arai, Hisayuki; Hanyu, Haruo; Kobayashi, Yasutaka; Hatano, Nobuyoshi; Katsunuma, Hideyo; Suzuki, Takanari; Amino, Saburo [Tokyo Medical Coll. (Japan)

    1990-12-01

    Regional cerebral blood flow (rCBF) was determined by single photon emission CT (SPECT) with N-isopropyl-p-({sup 123}I)iodoamphetamine in 22 patients with clinically diagnosed senile dementia of Alzheimer type (SDAT) and in 18 age matched controls. We calculated asymmetry indices (AIs) of rCBF for matched right-left regions of interest. rCBF of parietal lobe in SDAT patients was significantly most laterally asymmetrycal, but the least in occipital lobe. Lateral asymmetry of rCBF in SDAT patients correlated with asymmetry of language and visuospatial functions; decreased rCBF in the left parietal lobe was associated with language dysfunction, and that in the right parietal lobe, with viduospatial dysfunction. Furthermore cerebellar AIs correlated negatively with those of the cerebral hemisphere and lower frontal region in SDAT patients. The results demonstrate that rCBF measurement by {sup 123}I-IMP SPECT is useful to detect lateral asymmetry in reduction of rCBF in SDAT. (author).

  4. Asymmetry of cerebral blood flow in patients with senile dementia of Alzheimer type by SPECT using I-123 IMP

    International Nuclear Information System (INIS)

    Arai, Hisayuki; Hanyu, Haruo; Kobayashi, Yasutaka; Hatano, Nobuyoshi; Katsunuma, Hideyo; Suzuki, Takanari; Amino, Saburo

    1990-01-01

    Regional cerebral blood flow (rCBF) was determined by single photon emission CT (SPECT) with N-isopropyl-p-[ 123 I]iodoamphetamine in 22 patients with clinically diagnosed senile dementia of Alzheimer type (SDAT) and in 18 age matched controls. We calculated asymmetry indices (AIs) of rCBF for matched right-left regions of interest. rCBF of parietal lobe in SDAT patients was significantly most laterally asymmetrycal, but the least in occipital lobe. Lateral asymmetry of rCBF in SDAT patients correlated with asymmetry of language and visuospatial functions; decreased rCBF in the left parietal lobe was associated with language dysfunction, and that in the right parietal lobe, with viduospatial dysfunction. Furthermore cerebellar AIs correlated negatively with those of the cerebral hemisphere and lower frontal region in SDAT patients. The results demonstrate that rCBF measurement by 123 I-IMP SPECT is useful to detect lateral asymmetry in reduction of rCBF in SDAT. (author)

  5. The usefulness of treatment evaluation of severe heart failure by ECG-gated myocardial SPECT

    International Nuclear Information System (INIS)

    Ohkoshi, Nobuyuki; Watanabe, Shingo; Matsumoto, Tooru

    2011-01-01

    Our purpose of study was to investigate the usefulness of treatment evaluation of severe heart failure by Electrocardiogram (ECG)-gated myocardial single photon emission computed tomography (SPECT). We evaluated the cardiac function in the case of severe heart failure by gated SPECT and compared it with the cardiac function obtained by left ventriculography (LVG), echocardiography, cardiac MRI, and B-type natriuretic peptide (BNP) values. We investigated the correlation of ejection fraction (EF), time lag of wall motion between the septal and lateral walls of the left ventricle for cardiac resynchronization therapy (CRT) and wall thickening (WT). We classified the left ventricular (LV) into basal, middle and apical areas for comparison of WT. We investigated the effect of a perfusion defect score in these comparisons. The gated SPECT results were correlated with comparative subjects in EF. The results were correlated with MRI on the middle area of the LV in the comparison of WT. We thought it was possible that there was an effect from a perfusion defect score in a time lag comparison of wall motion. Treatment evaluation of severe heart failure by gated SPECT is useful, because it is able to obtain three-dimensional cardiac function analysis, and it offers objectivity and reproducible quantitative evaluation. At the same time, perfusion SPECT is helpful for CRT and LV-plasty. (author)

  6. I-123 Iofetamine SPECT scan in children with neurological disorders

    International Nuclear Information System (INIS)

    Flamini, J.R.; Konkol, R.J.; Wells, R.G.; Sty, J.R.

    1990-01-01

    I-123 Iofetamine (IMP) single photon emission computed tomography (SPECT) imaging of the brain in 42 patients (ages 14 days to 23 years) was compared with other localizing studies in children with neurological diseases. All had an EEG and at least one imaging study of the brain (computed tomography (CT) or magnetic resonance imaging (MRI), or both). Seventy-eight percent of the patients had an EEG within 24-72 hours of the IMP-SPECT scan. Thirty-five (83%) had a history of seizures, and the remainder had other neurological conditions without a history of seizures. In most cases, a normal EEG reading with normal CT or MRI result predicted a normal SPECT study. When the EEG was abnormal the majority of the IMP-SPECT scans were abnormal and localized the abnormality to the same region. A comparison with CT and MRI showed that structural abnormalities involving the cortex were usually well demonstrated with IMP-SPECT imaging. Structural lesions confined to the white matter were generally not detectable with IMP-SPECT. In a few cases, SPECT scans revealed abnormalities in deep brain areas not identified by EEG. IMP-SPECT imaging is a valuable technique for the detection and localization of abnormal cerebral metabolic activity in children with seizure disorders. A correlation with CT or MRI is essential for proper interpretation of abnormalities detected with IMP SPECT imaging

  7. Comparison between high-resolution computed tomography and 99mTc-technegas SPECT pulmonary emphysema

    International Nuclear Information System (INIS)

    Nakano, Satoru; Satoh, Katashi; Takahashi, Kazue

    1996-01-01

    Scintigraphy with 99m Tc-technegas was recently introduced for clinical imaging of lung ventilation. This method has been found to be useful in emergencies, to be more suitable for single photon emission computed tomography (SPECT) than other agents used in ventilation scintigraphy, and could reveal abnormalities in ventilation more easily than high resolution computed tomography (HRCT) in pulmonary emphysema. We compared 99m Tc-technegas SPECT with HRCT in six regions: the right upper, middle, and lower lobes, the left upper lobe, the lingula, and the left lower lobe, in 15 patients with pulmonary emphysema. Patients with centrilobular emphysema tended to show stronger changes in upper lobes than in lower lobes on both 99m Tc-technegas SPECT and HRCT. Some regions showed no change on HRCT but various changes on 99m Tc-SPECT. Patients with panlobular emphysema showed severe changes on 99m Tc-SPECT in lower lung fields in which well-demarcated areas of low attenuation were not seen on HRCT. We conclude that 99m Tc-SPECT is useful for detecting early changes and panlobular changes in pulmonary emphysema. (author)

  8. Investigation of regional cerebral blood flow in alcoholic Korsakoff's syndrome with 123I-IMP SPECT

    International Nuclear Information System (INIS)

    Nakamura, Makoto; Nomura, Soichiro; Kato, Motoichiro; Nakazawa, Tsuneyuki.

    1995-01-01

    Regional cerebral blood flow (rCBF) was determined quantitatively by single photon emission computed tomography (SPECT) using N-isopropyl-p-[ 123 I]iodoamphetamine ( 123 I-IMP) in 6 patients with alcoholic Korsakoff's syndrome (A group). The findings were compared with concurrently available findings from 6 alcoholic patients with no evidence of cerebral disordres such as Korsakoff's syndrome and dementia (B group) and 4 healthy persons (C group). In both A and B groups, diffuse decrease in blood flow was significantly observed in the entire brain, as compared with the C group; no significant difference in the decreased blood flow existed between the A and B groups. According to the WAIS results, the patients in the A group were classified as 'typical Korsakoff's syndrome' (full IQ of 90 or more) and as 'serious Korsakoff's syndrome' (full IQ of 89 or less). rCBF in the thalamus was significantly lower in the A group of patients with typical Korsakoff's syndrome than the B group. These findings may reflect the variety of alcoholic Korsakoff's syndrome. This may also have an implication for the possible classification of several types in this syndrome. (N.K.)

  9. Brain SPECT

    International Nuclear Information System (INIS)

    Feistel, H.

    1991-01-01

    Brain SPECT investigations have gained broad acceptance since the introduction of the lipophilic tracer Tc-99m-HMPAO. Depending on equipment and objectives in different departments, the examinations can be divided into three groups: 1. Under normal conditions and standardised patient preparation the 'rest' SPECT can be performed in every department with a tomographic camera. In cerebrovascular disease there is a demand for determination of either the perfusion reserve in reversible ischemia or prognostic values in completed stroke. In cases of dementia, SPECT may yield useful results according to differential diagnosis. Central cerebral system involvement in immunologic disease may be estimated with higher sensitivity than in conventional brain imaging procedures. In psychiatric diseases there is only a relative indication for brain SPECT, since results during recent years have been contradictory and may be derived only in interventional manner. In brain tumor diagnostics SPECT with Tl-201 possibly permits grading. In inflammatory disease, especially in viral encephalitis, SPECT may be used to obtain early diagnosis. Normal pressure hydrocephalus can be distinguished from other forms of dementia and, consequently, the necessity for shunting surgery can be recognised. 2. In departments equipped for emergency cases an 'acute' SPECT can be performed in illnesses with rapid changing symptoms such as different forms of migraine, transient global amnesia, epileptic seizures (so-called 'ictal SPECT') or urgent forms like trauma. 3. In cooperation with several departments brain SPECT can be practised as an interventional procedure in clinical and in scientific studies. (orig./MG) [de

  10. Interictal brain SPECT in patients with medically refractory temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Andraus, Maria Emilia Cosenza

    2000-06-01

    The brain single photon emission computed tomography (SPECT) is s functional neuroimaging method that can detect localized changes in cerebral blood flow. The temporal lobe epilepsy (TLE) is the most common epileptic syndrome in adults, and more than 50% are medically refractory. The SPECT can contribute to investigation of epileptogenic focus and is one of the methods of pre-surgical evaluation of these patients. (author)

  11. Normal regional distribution of cerebral blood flow in dogs: comparison between (99m) Tc-ethylcysteinate dimer and (99m) Tc- hexamethylpropylene amine oxime single photon emission computed tomography.

    Science.gov (United States)

    Adriaens, Antita; Polis, Ingeborgh; Waelbers, Tim; Vandermeulen, Eva; Dobbeleir, André; De Spiegeleer, Bart; Peremans, Kathelijne

    2013-01-01

    Functional imaging provides important insights into canine brain pathologies such as behavioral problems. Two (99m) Tc-labeled single photon emission computed tomography (SPECT) cerebral blood flow tracers-ethylcysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO)-are commonly used in human medicine and have been used previously in dogs but intrasubject comparison of both tracers in dogs is lacking. Therefore, this study investigated whether regional distribution differences between both tracers occur in dogs as is reported in humans. Eight beagles underwent two SPECT examinations first with (99m) Tc-ECD and followed by (99m) Tc-HMPAO. SPECT scanning was performed with a triple head gamma camera equipped with ultrahigh resolution parallel hole collimators. Images were reconstructed using filtered backprojection with a Butterworth filter. Emission data were fitted to a template permitting semiquantification using predefined regions or volumes of interest (VOIs). For each VOI, perfusion indices were calculated by normalizing the regional counts per voxel to total brain counts per voxel. The obtained perfusion indices for each region for both tracers were compared with a paired Student's T-test. Significant (P < 0.05) regional differences were seen in the subcortical region and the cerebellum. Both tracers can be used to visualize regional cerebral blood flow in dogs, however, due to the observed regional differences, they are not entirely interchangeable. © 2013 Veterinary Radiology & Ultrasound.

  12. Skull base osteomyelitis: role of three phase and hybrid SPECT/CT bone scintigraphy

    International Nuclear Information System (INIS)

    Chakraborty, D.; Bhattacharaya, A.; Kamaleshwaran, K.K.; Mittal, B.R.; Aggarwal, K.; Singh, B.; Bhoil, A.

    2010-01-01

    Full text: Skull base osteomyelitis is the infection that has spread to the skull base, beyond the external auditory canal and seen in advanced stage of malignant otitis externa. Early diagnosis of this condition includes the use of bone scintigraphy since clinical assessment alone cannot differentiate the skull base osteomyelitis from the severe type of otitis externa in which there is no extension to the adjacent bone. Objective: To determine the role of three phase bone scintigraphy and delayed SPECT/CT in detection of skull base osteomyelitis in patients with malignant otitis externa. Material and Methods: Clinical records of 20 patients (14 Males and 6 Females; mean age 72 yrs) of otitis externa with suspected skull base involvement referred for bone scintigraphies were analyzed retrospectively. Three phase bone scintigraphy was acquired under dual detector gamma camera after intravenous injection of 20 mCi (740 MBq) 99m Tc-MDP followed by SPECT/CT of the skull. Scintigraphic findings were compared with clinical symptoms, signs and diagnostic CT scan findings. Results: All the patients except one were diabetic and having elevated ESR. 18 patients presented with bilateral symptoms and rest unilateral. Cranial nerves were involved in 8 patients (40%). Ear discharge culture sensitivity report was found in three patients; it was positive for Pseudomonas aeruginosa for two patients and in Diptheroids for one. In 9 patients (45%) increased flow of tracer and 10 patients (50%) increased blood pool phase in the temporal region was found. Delayed phase images showed increased uptake in skull bone in 19 patients (95%). Hybrid SPECT/CT of the skull localized areas of increased tracer uptake to the mastoid part in 15 patients (75%), petrous part in 11 patients (55%), sphenoid in 3 patients (15%) and zygomatic bone in one patient (5%) with CT showing destructive changes in 5 patients (25%) which were corroborated with diagnostic CT findings. SPECT/CT along with three phase

  13. Attenuation correction of myocardial SPECT images with X-ray CT. Effects of registration errors between X-ray CT and SPECT

    International Nuclear Information System (INIS)

    Takahashi, Yasuyuki; Murase, Kenya; Mochizuki, Teruhito; Motomura, Nobutoku

    2002-01-01

    Attenuation correction with an X-ray CT image is a new method to correct attenuation on SPECT imaging, but the effect of the registration errors between CT and SPECT images is unclear. In this study, we investigated the effects of the registration errors on myocardial SPECT, analyzing data from a phantom and a human volunteer. Registerion (fusion) of the X-ray CT and SPECT images was done with standard packaged software in three dimensional fashion, by using linked transaxial, coronal and sagittal images. In the phantom study, and X-ray CT image was shifted 1 to 3 pixels on the x, y and z axes, and rotated 6 degrees clockwise. Attenuation correction maps generated from each misaligned X-ray CT image were used to reconstruct misaligned SPECT images of the phantom filled with 201 Tl. In a human volunteer, X-ray CT was acquired in different conditions (during inspiration vs. expiration). CT values were transferred to an attenuation constant by using straight lines; an attenuation constant of 0/cm in the air (CT value=-1,000 HU) and that of 0.150/cm in water (CT value=0 HU). For comparison, attenuation correction with transmission CT (TCT) data and an external γ-ray source ( 99m Tc) was also applied to reconstruct SPECT images. Simulated breast attenuation with a breast attachment, and inferior wall attenuation were properly corrected by means of the attenuation correction map generated from X-ray CT. As pixel shift increased, deviation of the SPECT images increased in misaligned images in the phantom study. In the human study, SPECT images were affected by the scan conditions of the X-ray CT. Attenuation correction of myocardial SPECT with an X-ray CT image is a simple and potentially beneficial method for clinical use, but accurate registration of the X-ray CT to SPECT image is essential for satisfactory attenuation correction. (author)

  14. Preliminary application of brain perfusion SPECT imaging in schizophrenia

    International Nuclear Information System (INIS)

    Wu Zhixing; Guo Chanliu; Li Xingbao; Liang Rongxiang; Zhao Jun; Yan Tingxiu

    1996-01-01

    The clinical value of 99m Tc-ECD brain perfusion SPECT imaging was evaluated in patients with schizophrenia. 32 patients with schizophrenia and 21 normal controls were analyzed with 99m Tc-ECD SPECT. 93.8% (30/32) of the patients showed decreased regional cerebral blood flow (rCBF). There was normal rCBF in controls. In the patient group rCBF decreased significantly in bilateral frontal lobes, left temporal lobe and right basal ganglion. The rCBF of left temporal lobe was significantly lower than that of right temporal lobe. The decreasing rCBF was not significantly related to previous treatment and duration of illness. 99m Tc-ECD SPECT is useful for the study and diagnosis of patients with schizophrenia

  15. Computer-assisted system for diagnosing degenerative dementia using cerebral blood flow SPECT and 3D-SSP. A multicenter study

    International Nuclear Information System (INIS)

    Ishii, Kazunari; Ito, Kengo; Nakanishi, Atsushi; Kitamura, Shin; Terashima, Akira

    2014-01-01

    Due to increasing numbers of patients with dementia, more physicians who do not specialize in brain nuclear medicine are being asked to interpret SPECT images of cerebral blood flow. We conducted a multicenter study to determine whether a computer-assisted diagnostic system Z-score summation analysis method (ZSAM) using three-dimensional stereotactic surface projections (3D-SSP) can differentiate Alzheimer's disease (AD)/dementia with Lewy bodies (DLB) and non-AD/DLB in institutions using various types of gamma cameras. We determined the normal thresholds of Z-sum (summed Z-score) within a template region of interest for each single photon emission computed tomography (SPECT) device and then compared them with the Z-sums of patients and calculated the accuracy of the differential diagnosis by ZSAM. We compared the diagnostic accuracy between ZSAM and visual assessment. We enrolled 202 patients with AD (mean age, 76.8 years), 40 with DLB (mean age 76.3 years) and 36 with non-AD/DLB (progressive supranuclear palsy, n=10; frontotemporal dementia, n=20; slowly progressive aphasia, n=2 and one each with idiopathic normal pressure hydrocephalus, corticobasal degeneration, multiple system atrophy and Parkinson's disease) who underwent N-isopropyl-p-[ 123 I] iodoamphetamine cerebral blood flow SPECT imaging at each participating institution. The ZSAM sensitivity to differentiate between AD/DLB and non-AD/DLB in all patients, as well as those with mini-mental state examination scores of ≥24 and 20-23 points were 88.0, 78.0 and 88.4%, respectively, with specificity of 50.0, 44.4 and 60.0%, respectively. The diagnostic accuracy rates were 83.1, 72.9 and 84.2%, respectively. The areas under receiver operating characteristics curves for visual inspection by four expert raters were 0.74-0.84, 0.66-0.85 and 0.81-0.93, respectively, in the same patient groups. The diagnostic accuracy rates were 70.9-89.2%, 50.9-84.8% and 76.2-93.1%, respectively. The diagnostic

  16. Ophthalmoplegic migraine with reversible thalamic ischemia by Tc-99m ethylcysteinate dimer brain SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Ho; Shin, Dong Jin; Kang, Sung Soo [Gachon Medical School, Gil Medical Center, Inchon (Korea, Republic of)

    1999-07-01

    Two patients presented with ophthalmoplegic migraine (OM) underwent EEG, Brain-MRI, cerebral angiography, and Tc-99m ECD SPECT during an attack. Follow-up SPECT was performed after neurologic symptoms resolved. In both cases, SPECT during an attack of ophthalmoplegia and headache demonstrated a significantly decreased regional cerebral blood flow in the thalamus to the side of ophthalmoplegia, which was normalized on the follow-up SPECT during a symptom free recovery phase (Lesion to Non-lesion thalamic ratio=1.19 to 0.96 and 1.16 to 0.98, respectively). The other roentgenographic and laboratory findings were normal. These findings are suggestive the ischemia in the perforators of PCA results in third nerve palsy because the portion of oculomotor nerve behind the cavernous sinus derives its blood supply from small perforating branches of the basilar and PCA. Matched ictal hypoperfusion of the thalamus to the site of ophthalmoplegic migraine is suggestive of the ischemic neuropathy as an etiology of OM.

  17. Cardiac functional mapping for thallium-201 myocardial perfusion, washout, wall motion and phase using single-photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Bunko, Hisashi; Taniguchi, Mitsuru; Taki, Junichi; Tonami, Norihisa; Hisada, Kinichi; Hirano, Takako; Wani, Hidenobu.

    1986-01-01

    A method for three-dimensional functional mapping of Tl-201 myocardial uptake, washout, wall motion and phase was developed using SPECT. Each parameter was mapped using polar display in the same format. Normal values were determined in Tl-201 exercise study in 16 patients. Myocardial counts were lower in the septum and inferior wall and the difference of counts between anterior and inferior walls were greater in man compared with the perfusion pattern in woman. Washout was slower at septum and inferior wall in man, and slightly slower at inferior wall in woman. In gated blood-pool tomography, length-based and count-based Fourier analyses were applied to calculate the parameters of contraction and phase. The results of both Fourier analyses generally agreed; however, the area of abnormality was slightly different. Phase maps were useful for the assessment of asynergy as well as in patients with conduction disorders. These cardiac functional maps using SPECT were considered to be effective for the understanding of three-dimensional informations of cardiac function. (author)

  18. Preserved benzodiazepine receptors in Alzheimer's disease measured with C-11 flumazenil PET and I-123 iomazenil SPECT in comparison with CBF

    International Nuclear Information System (INIS)

    Ohyama, Masashi; Kitamura, Shin; Mishina, Masahiro; Katayama, Yasuo; Senda, Michio; Ishiwata, Kiichi; Ishii, Kenji; Toyama, Hinako; Oda, Keiichi

    1999-01-01

    This study evaluates the regional cerebral blood flow (CBF) with H 2 15 O-PET and the distribution of central benzodiazepine receptor (BZR) with C-11 flumazenil (FMZ) by PET and I-123 iomazenil (IMZ) by SPECT in Alzheimer's disease (AD). In AD, whereas the CBF was diminished in the frontal, temporal, parietal, and occipital cortex, the distribution volume of FMZ and delayed activity of IMZ were relatively preserved in these cortices, suggesting that the BZR reduction, reflecting neuronal loss, is less prominent than the CBF suppression. The mini-mental state examination score (MMS) was weakly correlated with the CBF in the parietal cortex but not with BZR. It is speculated that the neuronal density reflected by BZR is less impaired than the neuronal function assessed with blood flow in the association cortex of AD. High correlation was found between the uptake of FMZ and the delayed activity of IMZ. The delayed image of IMZ-SPECT is clinically useful to evaluate the preservation of neuronal density in the affected temoporoparietal association cortex in AD. (author)

  19. Value of lateral blood pool imaging in patients with suspected stress fractures of the tibia.

    Science.gov (United States)

    Mohan, Hosahalli K; Clarke, Susan E M; Centenara, Martin; Lucarelli, Amanda; Baron, Daniel; Fogelman, Ignac

    2011-03-01

    To critically evaluate the use of lateral blood pool imaging in athletes with lower limb pain and with a clinical suspicion of stress fracture. Two experienced nuclear medicine physicians evaluated 3-phase bone scans using 99mTc-methylene diphosphonate performed in 50 consecutive patients referred from a specialist sports injury clinic for suspected tibial stress fracture. The vascularity to the tibia as seen on the blood pool (second phase) images in the anterior/posterior views was compared with the lateral/medial view assessments. Stress fractures were presumed to be present when on the delayed images (third phase) there was a focal or fusiform area of increased tracer uptake involving the tibial cortex. Shin splints which are a recognized cause of lower limb pain in athletes mimicking stress fracture were diagnosed if increased tracer uptake was seen extending along the posterior tibial surface with no significant focal or fusiform area of uptake within this. Inter-reviewer agreement for the assessment of vascularity was also assessed using Cohen's Kappa scores. Twenty-four stress fractures in 24 patients and 66 shin splints in 40 patients were diagnosed. In 18 patients stress fracture and shin splints coexisted. In 10 patients no tibial pathology was identified. Of the 24 patients diagnosed with stress fractures, lateral/medial blood pool imaging was superior in the assessment of blood pool activity (P tibial stress fractures, lateral views of the tibia provide the optimal method for evaluation of vascularity. Prospective studies with quantitative or semi-quantitative assessment of skeletal vascularity could provide supplementary information relating to the pathophysiology of stress fractures, for example, the time scale of vascular changes after a tibial stress fracture, and potentially could have clinical relevance as to the assessment of the severity of stress fractures and their prognosis.

  20. Evaluation of supine and sitting cardiac blood pool scans with sup(99m)Tc-HSA

    International Nuclear Information System (INIS)

    Bunko, Hisashi; Kuwajima, Akira; Hisada, Kinichi

    1977-01-01

    In the differential diagnosis of enlarged cardiac silhouette on plain chest x-ray film, cardiac blood pool scan was usually performed at first. However, small amount of pericardial effusion was difficult to detect on cardiac blood pool scan and differentiation of pericardial effusion from myocardial thickening was sometimes difficult. We evaluated cardiac blood pool scan with sup(99m)Tc-HSA(human serum albumin) and gamma camera imaged on both supine and sitting position, and evaluated diagnostic efficiency of criteria for pericardial effusion of these scans. Fifty-seven patients suspected of having pericardial effusion were included in the study. Sixteen of these patients had pericardial effusion and 2 of these 16 patients had free pleural effusion. Three patients had pleural effusion alone and excluded from the study. Of the five criteria for pericardial effusion, separation between heart and right lung activities was most frequent in both effusion (true positive, TP=100% on both supine and sitting) and no effusion (false positive, FP=18.4% on supine and 23.7% on sitting) groups. However, increased heart and right lung separation on sitting position was rather frequent in effusion group, and this finding was also thought to be typical for effusion but not for myocardial thickening. Decreased cardiohepatic separation on sitting position was frequent in no effusion group, and FP rate was decreased from 18.4% (supine) to 10.5% (sitting). Two patients with both pericardial effusion and free pleural effusion were easily diagnosed on sitting cardiac blood pool scan. With ROC(receiver operating characteristic) curve, three criteria should be agreed on either supine or sitting scan for diagnosis of pericardial effusion, and six criteria should be agreed when both supine and sitting scans were employed for diagnosis of pericardial effusion. (auth.)

  1. Neuroimaging of post-traumatic higher brain dysfunction using 123I-Iomazenil (IMZ) SPECT

    International Nuclear Information System (INIS)

    Nakagawara, Jyoji; Kamiyama, Kenji; Takahashi, Masaaki; Nakamura, Hirohiko

    2010-01-01

    In patients with mild traumatic brain injury (MTBI), higher brain dysfunctions which consist of cognitive impairments such as memory, attention, performance and social behavioral disturbances could be rarely apparent. However, higher brain dysfunctions should be identified by neuropsychological tests and supported by a social welfare for handicapped patients. Acknowledgement of higher brain dysfunctions after MTBI without obvious brain damages on morphological neuroimagings could be a social issue under controversy. An imaging of cortical neuron damages in patients with higher brain dysfunctions after MTBI was studied by functional neuroimaging using 123 I-Iomazenil (IMZ) single photon emission computed tomography (SPECT). Statistical imaging analyses using 3 dimensional stereotactic surface projections (3D-SSP) for 123 I-IMZ SPECT and 123 I-IMP SPECT as cerebral blood flow (CBF) studies were performed in 11 patients with higher brain dysfunctions after MTBI. In all patients with higher brain dysfunctions defined by neuropsychological tests, cortical neuron damages were observed in bilateral medial frontal lobes, but reduction of CBF in bilateral medial frontal lobes were less obviously showed in 8 patients (apparent in 3 and little in 5). Group comparison of 3D-SSP of 123 I-IMZ SPECT between 11 patients and 18 normal controls demonstrated significant selective loss of cortical neuron in bilateral medial frontal gyrus (MFG). Extent of abnormal pixels on each cortical gyrus using stereotactic extraction estimation (SEE) for 3D-SSP of 123 I-IMZ SPECT confirmed that 8 patients had abnormal pixel extent >10% in bilateral MFG and 5 patients had abnormal pixel extent >10% in bilateral anterior cingulate gyrus. In patients with MTBI, higher brain dysfunctions seems to correlate with selective loss of cortical neuron within bilateral MFG which could be caused by Wallerian degeneration as secondary phenomena after diffuse axonal injury within corpus callosum. Statistical

  2. Tc-99m-HMPAO neuroactivation SPECT in patients with Alzheimer's disease

    International Nuclear Information System (INIS)

    Klissarova, A.; Tranulov, G.; Deleva, D.; Kaprelyan, A.; Tjaneva, M.

    2002-01-01

    Aim: Tc-99m-HMPAO-SPECT detects the hypoperfusion areas in the temporal and parietal lobes as well as in the frontal lobes in the advanced stages of Alzheimer's disease. These hypoperfusion areas correlate with decreased glucose metabolism and oxygen utilization. The aim of the study was to establish the neuroactivation effect on the regional cerebral blood flow and on the hypoperfusion areas detected by means of Tc-99m-HMPAO-SPECT in patients with Alzheimer's disease. Materials and methods: Subject to the study were 22 patients with Alzheimer's disease divided into two groups according to the results from the neuropsychological tests as follows: Ist group - 10 patients with slight cognitive disturbances; IInd group - 12 patients with prominent cognitive impairment. All patients underwent Brain-SPECT after I.V. injection of 740 MBq Tc-99m-HMPAO at rest and during neuroactivation by labyrinth task on the next day. Regional blood flow was detected by means of the hypoperfusion indices calculated as follows: hypoperfusion areas in the temporal lobe and /or the parietal lobe to the referent areas of the cerebellum. The regional blood flow decrease in hypoperfusion areas was calculated in per cent. Results: Hypoperfusion areas were detected at rest in 5 patients from the Ist group and in all patients from the IInd group. A decrease of the regional cerebral blood flow by 5-10% was established after neuroactivation in all the seventeen patients with hypoperfusion areas at rest. After neuroactivation three of the patients with normal regional cerebral perfusion at rest revealed hypoperfusion areas in the posterior part of the parietal lobe and the temporo-parietal areas. The remaining two patients showed normal regional cerebral blood flow at rest and during neuroactivation. Conclusion: Neuroactivation reduces the regional cerebral blood flow in hypoperfusion areas at rest in patients with Alzheimer's disease. Neuroactivation Tc-99m-HMPAO SPECT is useful for the detection

  3. Support vector machine-based classification of neuroimages in Alzheimer’s disease: direct comparison of FDG-PET, rCBF-SPECT and MRI data acquired from the same individuals

    Directory of Open Access Journals (Sweden)

    Luiz K. Ferreira

    2017-10-01

    Full Text Available Objective: To conduct the first support vector machine (SVM-based study comparing the diagnostic accuracy of T1-weighted magnetic resonance imaging (T1-MRI, F-fluorodeoxyglucose-positron emission tomography (FDG-PET and regional cerebral blood flow single-photon emission computed tomography (rCBF-SPECT in Alzheimer’s disease (AD. Method: Brain T1-MRI, FDG-PET and rCBF-SPECT scans were acquired from a sample of mild AD patients (n=20 and healthy elderly controls (n=18. SVM-based diagnostic accuracy indices were calculated using whole-brain information and leave-one-out cross-validation. Results: The accuracy obtained using PET and SPECT data were similar. PET accuracy was 68∼71% and area under curve (AUC 0.77∼0.81; SPECT accuracy was 68∼74% and AUC 0.75∼0.79, and both had better performance than analysis with T1-MRI data (accuracy of 58%, AUC 0.67. The addition of PET or SPECT to MRI produced higher accuracy indices (68∼74%; AUC: 0.74∼0.82 than T1-MRI alone, but these were not clearly superior to the isolated neurofunctional modalities. Conclusion: In line with previous evidence, FDG-PET and rCBF-SPECT more accurately identified patients with AD than T1-MRI, and the addition of either PET or SPECT to T1-MRI data yielded increased accuracy. The comparable SPECT and PET performances, directly demonstrated for the first time in the present study, support the view that rCBF-SPECT still has a role to play in AD diagnosis.

  4. Bull's-eye map of myocardial perfusion MR imaging. Comparison with SPECT

    International Nuclear Information System (INIS)

    Nomura, Yukihiro; Nanjo, Shuji; Yamazaki, Junichi; Yoshikawa, Kohki; Inoue, Yusuke

    2003-01-01

    When diagnosing heart disease, chest roentgenograms, ultrasonography, single-photon emission computed tomography (SPECT), and coronary arteriography are usually performed. Magnetic resonance (MR) imaging is not widely used for evaluating heart disease. Recent technological progress has allowed high quality images of the heart to be reliably obtained. A routine MR study taking about 30-40 minutes can provide a large amount of diagnostic information, such as cardiac structure, function, perfusion, and myocardial viability. The analysis software that can offer Bull's-eye maps from myocardial perfusion images has recently become commercially available. In this study, the characteristics of Bull's-eye mapping of MR imaging is compared with that of Bull's-eye mapping of SPECT using the same heart phantom. The difference in the image quality of the Bull's-eye maps was evaluated among the receiver coils of MR imaging. On Bull's-eye maps from both MR imaging and SPECT, decreased signal intensity was noted in the posterolateral wall. The degree of decrease in the signal of the MR imaging was more prominent than of SPECT. The decrease was severe for the general-purpose receive-only flexible (GPFLEX) coil, moderate for the cardiac and TORSO coil, and slight for the body coil. In the selection of a coil, it is necessary to take into consideration the trade-off between the distribution of signal intensity and the signal-to-noise ratio (SNR). (author)

  5. Abdominal blood pool scintigraphy in the management of acute or intermittent gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Kalff, V.; Kelly, M.J.; Dudley, F.; Metz, G.

    1983-01-01

    Gastrointestinal blood pool scintigraphy, using a modified in-vivo blood cell labelling technique with technetium-99, is a new, easily performed, non-invasive procedure. It is valuable in screening patients with acute or intermittent gastrointestinal blood loss in whom duodenoscopic and sigmoidoscopic findings are unhelpful. This paper reviews the value of this scintigraphic technique over the first eight months of its use in a major teaching hospital, and compares the results with other published data. If used and interpreted appropriately, scintigraphy is sensitive in detecting and localizing the bleeding site, and is very helpful in indicating the optimal timing of emergency contrast angiography

  6. Prediction of residual lung function after lung surgery, and examination of blood perfusion in the pre- and postoperative lung using three-dimensional SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Shimatani, Shinji [Toho Univ., Tokyo (Japan). School of Medicine

    2001-01-01

    In order to predict postoperative pulmonary function after lung surgery, preoperative {sup 99m}Tc-macroaggregated albumin (MAA) lung perfusion scans with single-photon emission computed tomography (SPECT) were performed. Spirometry was also performed before and 4-6 months after surgery in 40 patients. In addition, changes in blood perfusion in the pre- and postoperative lung were examined by postoperative lung perfusion scans in 18 of the 40 patients. We measured the three-dimensional (3-D) imaging volume of the operative and contralateral lungs using the volumes rendering method at blood perfusion thresholds of 20, 50 and 75%, utilizing {sup 99m}Tc-MAA lung perfusion, and predicted pulmonary function by means of the measured volumes. We examined the correlation between predicted and the measured values of postoperative pulmonary function, forced vital capacity (FVC) and forced expiratory volume in one second (FEV{sub 1.0}). The correlation between FEV{sub 1.0} predicted by SPECT (threshold 50%) and measured postoperative lung function resembled that between lung function predicted by the standard planar method and measured FEV{sub 1.0} in the lobectomy group. We then examined the ratios of both pre- and postoperative blood perfusion volumes obtained using 3-D imaging at lung perfusion threshold ranges of 10% each (PV20-29, PV30-39) to pre- and postoperative total perfusion (PV20-100). In the lobectomy group, the postoperative PV20-29/PV20-100 value was significantly higher for the operative side lung than the preoperative PV20-29/PV20-100 value, and the postoperative PV50-59, 60-69, 70-79, 80-89 and 90-100/PV20-100 values were significantly lower than the respective preoperative values. However, in the contralateral lung, the respective pre- and postoperative PV/PV20-100 values were almost identical. These findings suggest that the rate of low blood perfusion increased while the rate of middle to high perfusion decreased in the lobectomy group in the operative

  7. SPECT versus planar scintigraphy for quantification of splenic sequestration of 111In-labelled platelets

    International Nuclear Information System (INIS)

    Savolainen, S.; Helsinki Univ. Central Hospital

    1992-01-01

    The splenic uptake of thrombocytes and spleen size were studied in 25 patients with idiopathic thrombocytopenic purpura (ITP) using two methods: anterior/posterior scintigraphy and single photon emission computed tomography (SPECT). Various factors (acquisition and reconstruction protocols) influencing the quality of 111 In SPECT were studied. The splenic uptake, measured by SPECT, was found to be significantly higher in patients with a high level of autoantibodies in the blood than in patients without such antibodies. The correlation between the spleen SPECT volume and the geometric mean size calculated as geometric mean of anterior and posterior images differed by more than 50% from the SPECT volume in some patients. Based on these observations and on the results of phantom studies, it is concluded that a reasonable estimate of the spleen:liver uptake ratio may be obtained using planar imaging, but to estimate the spleen volume and the absolute splenic uptake of platelets SPECT imaging is needed, in spite of the present technical limitations of SPECT. (Author)

  8. Ventilation-perfused studies using SPECT

    International Nuclear Information System (INIS)

    Zwijnenburg, A.

    1989-01-01

    A method for the quantitative analysis of ventilation-perfusion SPECT studies is decribed and an effort is made to evaluate its usefullness. The technical details of the emthod are described. In the the transaxial reconstructions of the tomographic studies the contour of the lungs is detected and regional values of lung volume, ventilation, perfusion and ventilation-perfusion ratios are calculated. The method is operator independent. The lung volume calculations from the SPECT studies are validated by comparing them with lung volume measurements using the helium dilution technique. A good correlation (r=0.91) was found between the two volumes. SPECT volume was greater than the volume measured with helium dilution, which was attributed to non-gas-containing structures in the. lungs. The use of ventilation-perfusion ratio SPECT is described to evaluate the effect of ionizing radiation on the lungs in patients treated with mantle field irradiation for Hodgkin's disease. Perfusion changes appear as early as 2 months after the start of irradiation. Ventilation changes appear later and relatively minor. No changes are seen outside the radiation portals. The ventilation-perfusion inequality in pulmonary sarcoidosis is treated. It is suggested that the decrease D LCO in these patients may be partly due to an even distribution of ventilation perfusion ratios. An effort is made to establish the properties of a new tracer used for the assessment of the metabolic function of the pulmonary endothelium. The lung uptake of I-123 IMP mimics the distribution of a perfusion tracer and it is suggested that this tracer may be useful for the early detection of pulmonary vascular damage, even when blood flow is still intact. Some aspects of the use of Kr-81m as a ventilation tracer are discussed as well as the effect of noise on Kr-81m SPECT reconstructions. (author). 146 refs.; 39 figs.; 8 tabs

  9. Effect of cerebral blood flow on consciousness and outcome after head injury. Assessment by jugular bulb venous metabolism and IMP-SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Imaizumi, Shigeki; Onuma, Takehide; Motohashi, Osamu; Kameyama, Motonobu; Ishii, Kiyoshi [Sendai City Hospital (Japan)

    2002-10-01

    This study was performed to elucidate the therapeutical value of arteriojugularvenous oxygen difference (AVDO{sub 2}) in the ultra-emergent period after head injury. Rational therapeutic strategy after severe head injury needs information concerning the dynamical change of cerebral blood flow (CBF) and metabolism. We monitored the cerebral venous metabolism within 6 hours after head injury until the day IMP-SPECT was performed. Whole brain cerebral blood flow detected by IMP-SPECT and AVDO{sub 2} at the same day was compared, which restored to the period within 6 hours after head injury. From this procedure, we could outline cerebral blood flow conditions by only AVDO{sub 2} without IMP-SPECT in the ultra-emergent period. Eighty-six patients with head injury who were carried to our emergency center in the period of recent 2 years aged ranging from 15 to 94 years were the subjects. They all performed jugular bulb cannulation within 6 hours after the accident (Martin's phase I: day 0) to know saturation of jugular vein (SjO{sub 2}), AVDO{sub 2} and AVL. They were monitored until the day IMP-SPECT was performed (Martin's phase II; day 1-3 or phase III; day 4-15). The correlation between CBF and AVDO{sub 2}. The effect of CBF and cerebral venous metabolism on consciousness and outcome was also analyzed. CBF and AVDO{sub 2} in phase II and III were reversely correlated (p<0.0001). Normal CBF corresponded with 5.0 vol% in AVDO{sub 2}. AVDO{sub 2} in all cases changed 6.2 vol% at phase I, 4.5 vol% at phase II and 5.1 vol% at phase III. Glasgow comascale (GCS) on admission under 8 (n=47) and over 9 (n=39) significantly differed in AVDO{sub 2} and CBF in the period of II and III. The patients with favorable consciousness showed low AVDO{sub 2} and hyperemia afterwards. Dead cases in phase I (n=19) showed high AVDO{sub 2} and low SjO{sub 2}. The patients with severe disability (SD) (n=13) showed high AVDO{sub 2} and low CBF and the patients with good recovery (GR

  10. Brain perfusion SPECT in children with frequent fits

    International Nuclear Information System (INIS)

    Heiskala, H.; Launes, J.; Pihko, H.; Nikkinen, P.; Santavuori, P.

    1993-01-01

    We studied 14 children with frequent fits using 99m Tc-HM-PAO single photon emission computed tomography (SPECT). There were 11 patients with partial secondary generalized epilepsy (PSGE) and 3 with Lennox-Gastaut syndrome (LGS). The typical regional cerebral blood flow (rCBF) finding in PSGE was a single area of abnormally low perfused cortex, and that in LGS, multiple hypoperfused areas. Clinically, the LGS patients were more severely affected. SPECT was more sensitive in detecting abnormalities than EEG, CT or MRI. Extensive impairment of rCBF may thus indicate unfavourable development of intellectual performance and poor seizure control. (author)

  11. Evaluation of role of brain SPECT in diagnosis of post stroke dementia

    International Nuclear Information System (INIS)

    Yousepour, G.; Alavi, M.

    2003-01-01

    Post stroke dementia is one of the most common complications of stroke that is preventable and relatively treatable too. The purpose of the study is comparison between the positive findings in the brain CT scan and brain perfusion SPECT. 15 patients who were complicated by dementia after cerebrovascular accident and also 5 patients as a control group enrolled in this study. Brain CT scan and brain SPECT were performed during at most one week after stroke. Abnormal findings in both brain CT scan and SPECT were seen in 46% of patients. Brain CT scan disclosed more abnormal findings compared to brain SPECT (33.3%). While brain SPECT findings were more information than brain CT scan (20%) this study is indicating that brain CT scan and the brain SPECT concomitantly for each other in better diagnosis of post stroke dementia. We did not find any specific diagnostic pattern in brain SPECT of patients suffering from post stroke dementia. The low quality of brain SPECT in spite of uniformity of gamma camera may be suggestive of low quality of Iran produced ECD kit that needs further evaluation

  12. Clinical assessment of SPECT/CT co-registration image fusion

    International Nuclear Information System (INIS)

    Zhou Wen; Luan Zhaosheng; Peng Yong

    2004-01-01

    Objective: Study the methodology of the SPECT/CT co-registration image fusion, and Assessment the Clinical application value. Method: 172 patients who underwent SPECT/CT image fusion during 2001-2003 were studied, 119 men, 53 women. 51 patients underwent 18FDG image +CT, 26 patients underwent 99m Tc-RBC Liver pool image +CT, 43 patients underwent 99mTc-MDP Bone image +CT, 18 patients underwent 99m Tc-MAA Lung perfusion image +CT. The machine is Millium VG SPECT of GE Company. All patients have been taken three steps image: X-ray survey, X-ray transmission and nuclear emission image (Including planer imaging, SPECT or 18 F-FDG of dual head camera) without changing the position of the patients. We reconstruct the emission image with X-ray map and do reconstruction, 18FDG with COSEM and 99mTc with OSEM. Then combine the transmission image and the reconstructed emission image. We use different process parameters in deferent image methods. The accurate rate of SPECT/CT image fusion were statistics, and compare their accurate with that of single nuclear emission image. Results: The nuclear image which have been reconstructed by X-ray attenuation and OSEM are apparent better than pre-reconstructed. The post-reconstructed emission images have no scatter lines around the organs. The outline between different issues is more clear than before. The validity of All post-reconstructed images is better than pre-reconstructed. SPECT/CT image fusion make localization have worthy bases. 138 patients, the accuracy of SPECT/CT image fusion is 91.3% (126/138), whereas 60(88.2%) were found through SPECT/CT image fusion, There are significant difference between them(P 99m Tc- RBC-SPECT +CT image fusion, but 21 of them were inspected by emission image. In BONE 99m Tc -MDP-SPECT +CT image fusion, 4 patients' removed bone(1-6 months after surgery) and their relay with normal bone had activity, their morphologic and density in CT were different from normal bones. 11 of 20 patients who could

  13. Comparison of early thallium-201 scintigraphy and gated blood pool imaging for predicting mortality in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Becker, L.C.; Silverman, K.J.; Bulkley, B.H.; Kallman, C.H.; Mellits, E.D.; Weisfeldt, M.

    1983-01-01

    The extent of abnormality in early thallium-201 and gated cardiac blood pool scintigrams has been reported to be useful for predicting mortality in patients with acute myocardial infarction (AMI). To compare the two techniques, 91 patients admitted consecutively with evident or strongly suspected AMI underwent both imaging studies within 15 hours of the onset of symptoms. Patients with pulmonary edema or shock were excluded. AMI developed in 84% of patients, and 6-month mortality for the entire group was 16%. A thallium defect score of 7.0 or greater identified a subgroup of 14 patients with 64% 6-month mortality rate. Similarly, a left ventricular ejection fraction of 35% or less identified a high-risk subgroup of 10 patients with a 6-month mortality of 60%. Mortality in the remaining patients was 8% for thallium score less than 7 and 11% for ejection fraction greater than 35%. The mortality rate was highest among patients who had concordant high-risk scintigrams (five of six, 83%), lowest in those with concordant low-risk studies (five of 64, 8%) and intermediate in those with discordant results (four of 11, 36%). Of a number of clinical variables, only the appearance of Q waves, peak creatine kinase greater than 1000 IU/I, and history of infarction were significantly associated with mortality. High-risk thallium or blood pool scintigraphic results were significantly more predictive and a thallium score of 7 or greater was more sensitive for detecting nonsurvivors than ejection fraction 35% or less at a similar level of specificity

  14. Automatic localization of the left ventricular blood pool centroid in short axis cardiac cine MR images.

    Science.gov (United States)

    Tan, Li Kuo; Liew, Yih Miin; Lim, Einly; Abdul Aziz, Yang Faridah; Chee, Kok Han; McLaughlin, Robert A

    2018-06-01

    In this paper, we develop and validate an open source, fully automatic algorithm to localize the left ventricular (LV) blood pool centroid in short axis cardiac cine MR images, enabling follow-on automated LV segmentation algorithms. The algorithm comprises four steps: (i) quantify motion to determine an initial region of interest surrounding the heart, (ii) identify potential 2D objects of interest using an intensity-based segmentation, (iii) assess contraction/expansion, circularity, and proximity to lung tissue to score all objects of interest in terms of their likelihood of constituting part of the LV, and (iv) aggregate the objects into connected groups and construct the final LV blood pool volume and centroid. This algorithm was tested against 1140 datasets from the Kaggle Second Annual Data Science Bowl, as well as 45 datasets from the STACOM 2009 Cardiac MR Left Ventricle Segmentation Challenge. Correct LV localization was confirmed in 97.3% of the datasets. The mean absolute error between the gold standard and localization centroids was 2.8 to 4.7 mm, or 12 to 22% of the average endocardial radius. Graphical abstract Fully automated localization of the left ventricular blood pool in short axis cardiac cine MR images.

  15. Automated region selection for analysis of dynamic cardiac SPECT data

    Science.gov (United States)

    Di Bella, E. V. R.; Gullberg, G. T.; Barclay, A. B.; Eisner, R. L.

    1997-06-01

    Dynamic cardiac SPECT using Tc-99m labeled teboroxime can provide kinetic parameters (washin, washout) indicative of myocardial blood flow. A time-consuming and subjective step of the data analysis is drawing regions of interest to delineate blood pool and myocardial tissue regions. The time-activity curves of the regions are then used to estimate local kinetic parameters. In this work, the appropriate regions are found automatically, in a manner similar to that used for calculating maximum count circumferential profiles in conventional static cardiac studies. The drawbacks to applying standard static circumferential profile methods are the high noise level and high liver uptake common in dynamic teboroxime studies. Searching along each ray for maxima to locate the myocardium does not typically provide useful information. Here we propose an iterative scheme in which constraints are imposed on the radii searched along each ray. The constraints are based on the shape of the time-activity curves of the circumferential profile members and on an assumption that the short axis slices are approximately circular. The constraints eliminate outliers and help to reduce the effects of noise and liver activity. Kinetic parameter estimates from the automatically generated regions were comparable to estimates from manually selected regions in dynamic canine teboroxime studies.

  16. Regional cerebral blood flow study of aphasic patients while reading aloud using N-isopropil-p-[123I]-iodoamphetamine SPECT

    International Nuclear Information System (INIS)

    Kishikawa, Yusuke

    1995-01-01

    N-isopropil-p-[ 123 I]-indoamphetamine SPECT (IMP-SPECT) image study was performed on seventeen aphasic patients (seven motor aphasics, seven sensory aphasics and three conduction aphasics) and eight normal controls to compare regional cerebral blood flow (rCBF) change between at rest and while reading aloud. Comparative analysis focused on the brain areas of Broca and Wernicke and their anatomically equivalent areas in the right hemisphere. The Wernicke area showed a higher rCBF change while reading aloud even in the sensory aphasic group, while the Broca area showed a lower rCBF change in the motor aphasic group compared to the normal control group. The anatomical equivalent of the Broca area in the right hemisphere appeared to play some role while reading aloud in the motor and conduction aphasic groups. As for the Wernicke area, the anatomically equivalent area in the right hemisphere showed no significant change in any aphasic group. Differences between the results obtained in these two areas suggested different functional specificities in the network of language function in the brain. (author)

  17. Post traumatic brain perfusion SPECT analysis using reconstructed ROI maps of radioactive microsphere derived cerebral blood flow and statistical parametric mapping

    OpenAIRE

    Gonzalez-Brito Manuel; Solano Juan; Sanchez Pablo; Georgiou Michael F; Capille Michael; McGoron Anthony J; Kuluz John W

    2008-01-01

    Abstract Background Assessment of cerebral blood flow (CBF) by SPECT could be important in the management of patients with severe traumatic brain injury (TBI) because changes in regional CBF can affect outcome by promoting edema formation and intracranial pressure elevation (with cerebral hyperemia), or by causing secondary ischemic injury including post-traumatic stroke. The purpose of this study was to establish an improved method for evaluating regional CBF changes after TBI in piglets. Me...

  18. Lung scintigraphy; Centellograma pulmonar

    Energy Technology Data Exchange (ETDEWEB)

    Dalenz, Roberto

    1994-12-31

    A review of lung scintigraphy, perfusion scintigraphy with SPECT, lung ventilation SPECT, blood pool SPECT. The procedure of lung perfusion studies, radiopharmaceutical, administration and clinical applications, imaging processing .Results encountered and evaluation criteria after Biello and Pioped. Recommendations and general considerations have been studied about relation of this radiopharmaceutical with other pathologies.

  19. Lung scintigraphy

    International Nuclear Information System (INIS)

    Dalenz, Roberto.

    1994-01-01

    A review of lung scintigraphy, perfusion scintigraphy with SPECT, lung ventilation SPECT, blood pool SPECT. The procedure of lung perfusion studies, radiopharmaceutical, administration and clinical applications, imaging processing .Results encountered and evaluation criteria after Biello and Pioped. Recommendations and general considerations have been studied about relation of this radiopharmaceutical with other pathologies

  20. Cardiac tumours: non invasive detection and assessment by gated cardiac blood pool radionuclide imaging

    International Nuclear Information System (INIS)

    Pitcher, D.; Wainwright, R.; Brennand-Roper, D.; Deverall, P.; Sowton, E.; Maisey, M.

    1980-01-01

    Four patients with cardiac tumours were investigated by gated cardiac blood pool radionuclide imaging and echocardiography. Contrast angiocardiography was performed in three of the cases. Two left atrial tumours were detected by all three techniques. In one of these cases echocardiography alone showed additional mitral valve stenosis, but isotope imaging indicated tumour size more accurately. A large septal mass was detected by all three methods. In this patient echocardiography showed evidence of left ventricular outflow obstruction, confirmed at cardiac catheterisation, but gated isotope imaging provided a more detailed assessment of the abnormal cardiac anatomy. In the fourth case gated isotope imaging detected a large right ventricular tumour which had not been identified by echocardiography. Gated cardiac blood pool isotope imaging is a complementary technique to echocardiography for the non-invasive detection and assessment of cardiac tumours. (author)

  1. Diagnosis of Popliteal Venous Entrapment Syndrome by Magnetic Resonance Imaging Using Blood-Pool Contrast Agents

    International Nuclear Information System (INIS)

    Beitzke, Dietrich; Wolf, Florian; Juelg, Gregor; Lammer, Johannes; Loewe, Christian

    2011-01-01

    Popliteal vascular entrapment syndrome is caused by aberrations or hypertrophy of the gastrocnemius muscles, which compress the neurovascular structures of the popliteal fossa, leading to symptoms of vascular and degeneration as well as aneurysm formation. Imaging of popliteal vascular entrapment may be performed with ultrasound, magnetic resonance imaging (MRI), computed tomography angiography, and conventional angiography. The use of blood-pool contrast agents in MRI when popliteal vascular entrapment is suspected offers the possibility to perform vascular imaging with first-pass magnetic resonance angiographic, high-resolution, steady-state imaging and allows functional tests all within one examination with a single dose of contrast agent. We present imaging findings in a case of symptomatic popliteal vein entrapment diagnosed by the use of blood pool contrast-enhanced MRI.

  2. Regional cerebral blood flow in children with autism spectrum disorders: a quantitative 99mTc-ECD brain SPECT study with statistical parametric mapping evaluation

    Institute of Scientific and Technical Information of China (English)

    YANG Wen-han; JING Jin; XIU Li-juan; CHENG Mu-hua; WANG Xin; BAO Peng; WANG Qing-xiong

    2011-01-01

    Background Autism spectrum disorders (ASD), which include autism, asperger syndrome (AS) and pervasive developmental disorder-not otherwise specified (PDD-NOS), are devastating neurodevelopmental disorders of childhood resulting in deficits in social interaction, repetitive patterns of behaviors, and restricted interests and activities. Single photon emission computed tomography (SPECT) is a common technique used to measure regional cerebral blood flow (rCBF). Several studies have measured rCBF in children with ASD using SPECT, however, findings are discordant. In addition, the majority of subjects used in these studies were autistic. In this study, we aimed to investigate changes in rCBF in children with ASD using SPECT.Methods A Technetium-99m-ethyl cysteinate dimmer (99mTc-ECD) brain SPECT study was performed on an ASD group consisting of 23 children (3 girls and 20 boys; mean age (7.2±3.0) years) who were diagnosed according to Diagnostic and Statistical Manual of Mental Disorders, 4th edition (DSM-Ⅳ) criteria and an age-matched control group with 8children (1 girl and 7 boys, mean age (5.5±2.4) years). Image data were evaluated with Statistical Parametric Mapping,5th version (SPM5). A Student's t test for unpaired data was used to compare rCBF and asymmetry in the autism and corresponding control group. The covariance analysis, taking age as covariance, was performed between the ASD and control group.Results There was a significant reduction in rCBF in the bilateral frontal lobe (frontal poles, arcula frontal gyrus) and the bilateral basal ganglia in the autism group, and a reduction in the bilateral frontal, temporal, parietal, legumina nucleus and cerebellum in the AS group compared to the control. In addition, asymmetry of hemispheric hypoperfusion in the ASD group was observed. Inner-group comparison analysis revealed that rCBF decreased significantly in the bilateral frontal lobe (42.7%), basal nucleus (24.9%) and temporal lobe (22.8%) in the autism

  3. 4D RECONSTRUCTIONS FROM LOW-COUNT SPECT DATA USING DEFORMABLE MODELS WITH SMOOTH INTERIOR INTENSITY VARIATIONS

    International Nuclear Information System (INIS)

    Cunningham, G. S.; Lehovich, A.

    2000-01-01

    The Bayes Inference Engine (BIE) has been used to perform a 4D reconstruction of a first-pass radiotracer bolus distribution inside a CardioWest Total Artificial Heart, imaged with the University of Arizona's FastSPECT system. The BIE estimates parameter values that define the 3D model of the radiotracer distribution at each of 41 times spanning about two seconds. The 3D models have two components: a closed surface, composed of hi-quadratic Bezier triangular surface patches, that defines the interface between the part of the blood pool that contains radiotracer and the part that contains no radiotracer, and smooth voxel-to-voxel variations in intensity within the closed surface. Ideally, the surface estimates the ventricular wall location where the bolus is infused throughout the part of the blood pool contained by the right ventricle. The voxel-to-voxel variations are needed to model an inhomogeneously-mixed bolus. Maximum a posterior (MAP) estimates of the Bezier control points and voxel values are obtained for each time frame. We show new reconstructions using the Bezier surface models, and discuss estimates of ventricular volume as a function of time, ejection fraction, and wall motion. The computation time for our reconstruction process, which directly estimates complex 3D model parameters from the raw data, is performed in a time that is competitive with more traditional voxel-based methods (ML-EM, e.g.)

  4. Brain pertechnetate SPECT in perinatal asphyxia

    Energy Technology Data Exchange (ETDEWEB)

    Sfakianakis, G.; Curless, R.; Goldberg, R.; Clarke, L.; Saw, C.; Sfakianakis, E.; Bloom, F.; Bauer, C.; Serafini, A.

    1984-01-01

    Single photon emission computed tomography of the brain was performed in 6 patients with perinatal asphyxis aged 8-26 days. A single-head (LFOV) commercial SPECT system (Picker) was used and data were acquired 2-3 hr after an IV injection of 1-2 mCi Tc-99m-pertechnetate (360/sup 0/ rotation, 60 views, 64 x 64 matrix, 50K cts/view). Reconstruction in three planes was performed using MDS software (Hanning medium resolution filter, with or without attenuation correction using Sorenson's technique). For each clinical study, a ring type phantom source was used to identify the level of reconstruction noise in the tomographic planes. Abnormalities were found in all patients studied, 3 central (moderate intensity), 2 peripheral (1 severe, 1 moderate) and 1 diffuse (mild intensity). Despite use of oral perchlorate (50 mg) in one patient the choroid plexus was visible. Since attenuation correction tended to amplify noise, the clinical studies were interpreted both with and without this correction. All 3 patients with central lesions were found abnormal on early (1-4 mo) neurologic follow-up examination, whereas the others were normal. No correlation was found between SPECT and 24 hr blood levels of CPK, ammonia, base excess, or the Apgar scores. Ct scans were reported abnormal (3 diffuse, 1 peripheral, 1 central and 1 questionable). Planar scintigrams obtained immediately after SPECT were normal (2), questionable (2) and abnormal (2). Follow-up SPECT brain scintigrams in two of the patients showed partial resolution. SPECT of the brain appears promising in perinatal asphyxia but long-term correlation with patient development is necessary.

  5. Comparison of {sup 99m}Tc-HMPAO SPECT and MRI after Acute and Subacute Closed-Head Injury

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Won Jong; Lee, Sang Hoon; Sohn, Hyung Sun; Lee, Han Jin; Park, Jeong Mi; Chung, Soo Kyo; Kim, Choon Yul; Bahk, Yong Whee; Shin, Kyung Sub [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1994-10-15

    The purpose of this study was to compare {sup 99m}Tc-HMPAO SPECT with MRI after acute and subacute closed head injury. There were thirty two focal lesions in all cases of these, Fifteen lesions(47%) were seen on both MRI and SPECT. Fourteen lesions(44%) were seen only on MRI. Three lesions(9%) were seen only on SPECT. Of the 14 lesions seen only on MRl, one was epidural hematoma, two were subdural hematoma, three were subdural hygroma, one was intracerebral hematoma, four were contusion, and three were diffuse axonal injuries. SPECT detected 52% of the focal lesions found on MRI. For the detection of lesions, MRl was superior to SPECT in fourteen cases, while SPECT was superior to MRI in three cases. In conclusion, there was a tendency that detection rate of the traumatic lesions was higher on MRI, but the SPECT could delineate more wide extent of lesion.

  6. Clinical validation of fully automated computation of ejection fraction from gated equilibrium blood-pool scintigrams

    International Nuclear Information System (INIS)

    Reiber, J.H.C.; Lie, S.P.; Simoons, M.L.; Hoek, C.; Gerbrands, J.J.; Wijns, W.; Bakker, W.H.; Kooij, P.P.M.

    1983-01-01

    A fully automated procedure for the computation of left-ventricular ejection fraction (EF) from cardiac-gated Tc-99m blood-pool (GBP) scintigrams with fixed, dual, and variable ROI methods is described. By comparison with EF data from contrast ventriculography in 68 patients, the dual-ROI method (separate end-diastolic and end-systolic contours) was found to be the method of choice; processing time was 2 min. Success score of dual-ROI procedure was 92% as assessed from 100 GBP studies. Overall reproducibility of data acquisition and analysis was determined in 12 patients. Mean value and standard deviation of differences between repeat studies (average time interval 27 min) were 0.8% and 4.3% EF units, respectively, (r=0.98). The authors conclude that left-ventricular EF can be computed automatically from GBP scintigrams with minimal operator-interaction and good reproducibility; EFs are similar to those from contrast ventriculography

  7. The study on regional brain blood flow in the patients with Parkinson's disease using 99Tcm-ECD SPECT

    International Nuclear Information System (INIS)

    Sun Da; Ye Xiaojuan; Zhan Hongwei; Xu Wei; Bao Chengkan

    2010-01-01

    Purpose The aim of this study is to evaluate the changes of brain blood floe in patients with Parkinson's disease (PD) and to investigate the clinical characteristics of the patients with PD correlate with rCBF. Methods: Regional cerebral perfusion was investigated using SPECT in 34 patients with PD . The mean ages of the patients were 56.61±11.04 Years old. The course of disease in most patients was from 1 to over 20 years. Results: 94.1 per cent of patients (32/3) had a significant decrease of rCBF in the basal ganglia, frontal lobes, temporal lobes and thalamus. Parietal and occipital cortex were involved in some patients. The decrease of rCBF in the basal ganglia is unilateral in most patients with PD. There were over 3 brain regions that Conclusion: According to our results, patients with PD had decreased rCBF in the basal ganglia, frontal and temporal cortices. These may reflect a fundamental feature of clinical neuropathophysiology in PD. 99 Tc m -ECD SPECT imaging is helpful to the diagnosis of PD and may help investigate the potential pathophysiology of PD. (authors)

  8. Dynamic molecular imaging of cardiac innervation using a dual headpinhole SPECT system

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Jicun; Boutchko, Rostyslav; Sitek, Arkadiusz; Reutter, BryanW.; Huesman, Ronald H.; Gullberg, Grant T.

    2008-03-29

    Typically 123I-MIBG is used for the study of innervation andfunction of the sympathetic nervous system in heart failure. The protocolinvolves two studies: first a planar or SPECT scan is performed tomeasure initial uptake of the tracer, followed some 3-4 hours later byanother study measuring the wash-out of the tracer from the heart. A fastwash-out is indicative of a compromised heart. In this work, a dual headpinhole SPECT system was used for imaging the distribution and kineticsof 123I-MIBG in the myocardium of spontaneous hypertensive rats (SHR) andnormotensive Wistar Kyoto (WKY) rats. The system geometry was calibratedbased on a nonlinear point projection fitting method using a three-pointsource phantom. The angle variation effect of the parameters was modeledwith a sinusoidal function. A dynamic acquisition was performed byinjecting 123I-MIBG into rats immediately after starting the dataacquisition. The detectors rotated continuously performing a 360o dataacquisition every 90 seconds. We applied the factor analysis (FA)methodand region of interest (ROI) sampling method to obtain time activitycurves (TACs)in the blood pool and myocardium and then appliedtwo-compartment modeling to estimate the kinetic parameters. Since theinitial injection bolus is too fast for obtaining a consistenttomographic data set in the first few minutes of the study, we appliedthe FA method directly to projections during the first rotation. Then thetime active curves for blood and myocardial tissue were obtained from ROIsampling. The method was applied to determine if there were differencesin the kinetics between SHR and WKY rats and requires less time byreplacing the delayed scan at 3-4 hours after injection with a dynamicacquisition over 90 to 120 minutes. The results of a faster washout and asmaller distribution volume of 123IMIBG near the end of life in the SHRmodel of hypertrophic cardiomyopthy may be indicative of a failing heartin late stages of heart failure.

  9. Clinical utility of SPECT neuroimaging in the diagnosis and treatment of traumatic brain injury: a systematic review.

    Directory of Open Access Journals (Sweden)

    Cyrus A Raji

    Full Text Available PURPOSE: This systematic review evaluated the clinical utility of single photon emission computed tomography (SPECT in traumatic brain injury (TBI. METHODS: After defining a PICO Statement (Population, Intervention, Comparison and Outcome Statement, PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria were applied to identify 1600 articles. After screening, 374 articles were eligible for review. Inclusion for review was focus on SPECT in the setting of mild, moderate, or severe TBI with cerebral lobar specificity of SPECT findings. Other inclusion criteria were comparison modalities in the same subjects and articles in English. Foreign language articles, SPECT studies that did not include comparison modalities, and case reports were not included for review. RESULTS: We identified 19 longitudinal and 52 cross-sectional studies meeting inclusion criteria. Three longitudinal studies examined diagnostic predictive value. The first showed positive predictive value increases from initial SPECT scan shortly after trauma to one year follow up scans, from 59% to 95%. Subsequent work replicated these results in a larger cohort. Longitudinal and cross sectional studies demonstrated SPECT lesion localization not detected by CT or MRI. The most commonly abnormal regions revealed by SPECT in cross-sectional studies were frontal (94% and temporal (77% lobes. SPECT was found to outperform both CT and MRI in both acute and chronic imaging of TBI, particularly mild TBI. It was also found to have a near 100% negative predictive value. CONCLUSIONS: This review demonstrates Level IIA evidence (at least one non-randomized controlled trial for the value of SPECT in TBI. Given its advantages over CT and MRI in the detection of mild TBI in numerous studies of adequate quality, and given its excellent negative predictive value, it may be an important second test in settings where CT or MRI are negative after a closed head injury with post

  10. Clinical utility of SPECT neuroimaging in the diagnosis and treatment of traumatic brain injury: a systematic review.

    Science.gov (United States)

    Raji, Cyrus A; Tarzwell, Robert; Pavel, Dan; Schneider, Howard; Uszler, Michael; Thornton, John; van Lierop, Muriel; Cohen, Phil; Amen, Daniel G; Henderson, Theodore

    2014-01-01

    This systematic review evaluated the clinical utility of single photon emission computed tomography (SPECT) in traumatic brain injury (TBI). After defining a PICO Statement (Population, Intervention, Comparison and Outcome Statement), PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) criteria were applied to identify 1600 articles. After screening, 374 articles were eligible for review. Inclusion for review was focus on SPECT in the setting of mild, moderate, or severe TBI with cerebral lobar specificity of SPECT findings. Other inclusion criteria were comparison modalities in the same subjects and articles in English. Foreign language articles, SPECT studies that did not include comparison modalities, and case reports were not included for review. We identified 19 longitudinal and 52 cross-sectional studies meeting inclusion criteria. Three longitudinal studies examined diagnostic predictive value. The first showed positive predictive value increases from initial SPECT scan shortly after trauma to one year follow up scans, from 59% to 95%. Subsequent work replicated these results in a larger cohort. Longitudinal and cross sectional studies demonstrated SPECT lesion localization not detected by CT or MRI. The most commonly abnormal regions revealed by SPECT in cross-sectional studies were frontal (94%) and temporal (77%) lobes. SPECT was found to outperform both CT and MRI in both acute and chronic imaging of TBI, particularly mild TBI. It was also found to have a near 100% negative predictive value. This review demonstrates Level IIA evidence (at least one non-randomized controlled trial) for the value of SPECT in TBI. Given its advantages over CT and MRI in the detection of mild TBI in numerous studies of adequate quality, and given its excellent negative predictive value, it may be an important second test in settings where CT or MRI are negative after a closed head injury with post-injury neurological or psychiatric symptoms.

  11. Comparison of FDG-PET and IMP-SPECT in patients with dementia with Lewy bodies

    International Nuclear Information System (INIS)

    Ishii, Kazunari; Hosaka, Kayo; Mori, Tetsuya; Mori, Etsuro

    2004-01-01

    To investigate regional differences in cerebral glucose metabolism and blood flow of dementia with Lewy bodies (DLB), we studied 7 subjects with DLB and 20 normal controls using F-18 fluorodeoxyglucose (FDG) and positron emission tomography (PET) and then examined the same 7 subjects and 20 other normal controls with I-123 iodoamphetamine (IMP) and single photon emission computed tomography (SPECT). The anatomically standardized images were produced with NEUROSTAT and the regional relative metabolic and perfusional values were calculated. The mean reduction ratios of FDG uptake in the DLB group relative to the mean normal controls in the parietal lobe and occipital lobe were 0.72 and 0.83, respectively, while the corresponding mean reduction ratios of IMP uptake were 0.81 and 0.88, respectively. In the DLB group, parietal FDG uptake was significantly lower than parietal IMP uptake (p<0.05), occipital FDG uptake was significantly lower than occipital IMP uptake (p<0.05), and parietal IMP uptake was significantly lower than occipital IMP uptake (p<0.01), but there was no difference between parietal and occipital FDG uptake. Our findings suggest that parietal metabolism and perfusion are severely affected in DLB patients, though the occipital metabolic and perfusional reduction is thought to be a feature of DLB. FDG-PET is thought to be superior to IMP-SPECT in detecting functional changes in the DLB brain. (author)

  12. Optimization method for the administered activity to patients in Tc-99-HMPAO cerebral blood flow SPECT in adults

    International Nuclear Information System (INIS)

    Perez Diaz, Marlen; Estevez Aparicio, Eric; Roque Diaz, Reinaldo; Hernandez Rodriguez, Carlos

    2002-01-01

    A method based on the construction of an image quality discriminant function is proposed. The parameters which characterise it are selected among the typical ones measured in a Tc 99m - HMPAO cerebral blood flow SPECT. The results are compared among groups of patient's studies who received different activity (430, 640 and 807 MBq), looking for the minimum that guaranty good image quality. A reduction in the administered 99m Tc-HMPAO activity to the patient down to 430 MBq was possible without affecting the tomographic image quality. The labelling yield was the main parameter that determined the image quality. (author)

  13. Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols

    International Nuclear Information System (INIS)

    Verger, Antoine; Karcher, Gilles; Djaballah, Wassila; Fourquet, Nicolas; Rouzet, Francois; Le Guludec, Dominique; Koehl, Gregoire; Roch, Veronique; Imbert, Laetitia; Poussier, Sylvain; Fay, Renaud; Marie, Pierre-Yves

    2013-01-01

    The results of stress myocardial perfusion SPECT could be enhanced by new cadmium-zinc-telluride (CZT) cameras, although differences compared to the results with conventional Anger cameras remain poorly known for most study protocols. This study was aimed at comparing the results of CZT and Anger SPECT according to various study protocols while taking into account the influence of obesity. The study population, which was from three different institutions equipped with identical CZT cameras, comprised 276 patients referred for study using protocols involving 201 Tl (n = 120) or 99m Tc-sestamibi injected at low dose at stress ( 99m Tc-Low; stress/rest 1-day protocol; n = 110) or at high dose at stress ( 99m Tc-High; rest/stress 1-day or 2-day protocol; n = 46). Each Anger SPECT scan was followed by a high-speed CZT SPECT scan (2 to 4 min). Agreement rates between CZT and Anger SPECT were good irrespective of the study protocol (for abnormal SPECT, 201 Tl 92 %, 99m Tc-Low 86 %, 99m Tc-High 98 %), although quality scores were much higher for CZT SPECT with all study protocols. Overall correlations were high for the extent of myocardial infarction (r = 0.80) and a little lower for ischaemic areas (r = 0.72), the latter being larger on Anger SPECT (p 201 Tl or 99m Tc-Low group and in whom stress myocardial counts were particularly low with Anger SPECT (228 ± 101 kcounts) and dramatically enhanced with CZT SPECT (+279 ± 251 %). Concordance between the results of CZT and Anger SPECT is good regardless of study protocol and especially when excluding obese patients who have low-count Anger SPECT and for whom myocardial counts are dramatically enhanced on CZT SPECT. (orig.)

  14. Relationship between SPECT regional cerebral blood flow imaging and cognitive function in school-age children with epilepsy

    International Nuclear Information System (INIS)

    Liu Jiangyan; Chen Xuehong; Wang Zhengjiang; Hu Jingui; Feng Jianzhong; Li Yimin; Lu Xiujuan

    2006-01-01

    Objective: To explore the feature of SPECT regional cerebral blood flow(rCBF) imaging, the cognitive functions and the relationship between them in school-age children with primary epilepsy. Methods: 99 Tc m -ethylene cysteinate dimer (ECD) brain imaging was performed on 32 school-age children with primary generalized tonic and (or) clonic seizures(GTCS). Cognitive functions were also evaluated in all patients and normal children. Relationship between cognitive function and rCBF was compared. Results: (1) Thirty of 32 (93.8%) patients were abnormal on SPECT imaging. Fifty areas of 29 cases showed decreased rCBF, the percentage of decreased rCBF was (21.07 ± 7.09)%; 2 areas of 1 case showed increased rCBF, the percentage of increased rCBF was (32.22 ± 4.31)%. 92.3% of the epileptic foci were located in frontal, temporal, parietal and occipital cortexes. (2) Verbal intelligence quotient (VIQ), performance intelligence quotient (PIQ) and full-scale intelligence quotient (FIQ) of children with epilepsy were significantly lower than those of the controls, and there were some cognitive skewnesses in children with epilepsy (VIQ >PIQ). (3)There was negative correlation between the number of foci and VIQ, PIQ, FIQ, the correlation coefficients were -0.543 (P=0.002), -0.469 (P=0.009), -0.578 (P=0.001); there was negative correlation between the extent of foci and VIQ, PIQ, FIQ, the correlation coefficients were -0.560 (P=0.003), -0.142 (P=0.016), -0.582 (P=0.001); there was no significant correlation between all the IQ of cognitive test and the percentage of changed rCBF. Conclusions: SPECT rCBF imaging may be useful for the localization of epileptic focus. Some of school-age children with epilepsy have impairment of the cognitive function, its magnitude is negative correlated with the number and extent of epileptic foci. (authors)

  15. Combined blood pool and extracellular contrast agents for pediatric and young adult cardiovascular magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Joyce T. [Ann and Robert Lurie Children' s Hospital of Chicago, Division of Pediatric Cardiology, 225 E. Chicago Ave., Box 21, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Robinson, Joshua D. [Ann and Robert Lurie Children' s Hospital of Chicago, Division of Pediatric Cardiology, 225 E. Chicago Ave., Box 21, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Deng, Jie [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); Rigsby, Cynthia K. [Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States)

    2016-12-15

    A comprehensive cardiac magnetic resonance (cardiac MR) study including both late gadolinium enhancement (LGE) and MR angiography may be indicated for patients with a history of acquired or congenital heart disease. To study the novel use of an extracellular agent for assessment of LGE combined with a blood pool contrast agent for detailed MR angiography evaluation to yield a comprehensive cardiac MR study in these patients. We reviewed clinical cardiac MR studies utilizing extracellular and blood pool contrast agents and noted demographics, clinical data and adverse events. We rated LGE image quality and MR angiography image quality for each vascular segment and calculated inter-rater variability. We also quantified contrast-to-noise ratio (CNR). Thirty-three patients (mean age 13.9 ± 3 years) received an extracellular contrast agent (10 gadobenate dimeglumine, 23 gadopentetate dimeglumine) and blood pool contrast agent (33 gadofosveset trisodium). No adverse events were reported. MRI indications included Kawasaki disease (8), cardiomyopathy and coronary anatomy (15), repaired congenital heart disease (8), and other (2). Mean LGE quality was 2.6 ± 0.6 with 97% diagnostic imaging. LGE quality did not vary by type of contrast agent given (P = 0.07). Mean MR angiography quality score was 4.7 ± 0.6, with high inter-rater agreement (k = 0.6-0.8, P < 0.002). MR angiography quality did not vary by type of contrast agent used (P = 0.6). Cardiac MR studies utilizing both extracellular and blood pool contrast agents are feasible and safe and provide excellent-quality LGE and MR angiography images. The use of two contrast agents allows for a comprehensive assessment of both myocardial viability and vascular anatomy during the same exam. (orig.)

  16. Combined blood pool and extracellular contrast agents for pediatric and young adult cardiovascular magnetic resonance imaging

    International Nuclear Information System (INIS)

    Johnson, Joyce T.; Robinson, Joshua D.; Deng, Jie; Rigsby, Cynthia K.

    2016-01-01

    A comprehensive cardiac magnetic resonance (cardiac MR) study including both late gadolinium enhancement (LGE) and MR angiography may be indicated for patients with a history of acquired or congenital heart disease. To study the novel use of an extracellular agent for assessment of LGE combined with a blood pool contrast agent for detailed MR angiography evaluation to yield a comprehensive cardiac MR study in these patients. We reviewed clinical cardiac MR studies utilizing extracellular and blood pool contrast agents and noted demographics, clinical data and adverse events. We rated LGE image quality and MR angiography image quality for each vascular segment and calculated inter-rater variability. We also quantified contrast-to-noise ratio (CNR). Thirty-three patients (mean age 13.9 ± 3 years) received an extracellular contrast agent (10 gadobenate dimeglumine, 23 gadopentetate dimeglumine) and blood pool contrast agent (33 gadofosveset trisodium). No adverse events were reported. MRI indications included Kawasaki disease (8), cardiomyopathy and coronary anatomy (15), repaired congenital heart disease (8), and other (2). Mean LGE quality was 2.6 ± 0.6 with 97% diagnostic imaging. LGE quality did not vary by type of contrast agent given (P = 0.07). Mean MR angiography quality score was 4.7 ± 0.6, with high inter-rater agreement (k = 0.6-0.8, P < 0.002). MR angiography quality did not vary by type of contrast agent used (P = 0.6). Cardiac MR studies utilizing both extracellular and blood pool contrast agents are feasible and safe and provide excellent-quality LGE and MR angiography images. The use of two contrast agents allows for a comprehensive assessment of both myocardial viability and vascular anatomy during the same exam. (orig.)

  17. Gallium-68-DOTA-albumin as a PET blood-pool marker: experimental evaluation in vivo

    International Nuclear Information System (INIS)

    Hoffend, Johannes; Mier, Walter; Schuhmacher, Jochen; Schmidt, Kerstin; Dimitrakopoulou-Strauss, Antonia; Strauss, Ludwig G.; Eisenhut, Michael; Kinscherf, Ralf; Haberkorn, Uwe

    2005-01-01

    Investigations into tumor angiogenesis and antiangiogenic treatment have renewed interest in tumor perfusion. To image tumor blood-pool by PET, suitable tracers are not generally available. In this experimental study, we characterized a 68 Ga-labeled 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) conjugate of rat serum albumin ( 68 Ga-DOTA-RSA) in vivo using a generator-produced isotope. Biodistribution was determined in ACI rats after intravenous administration of 3-6 MBq of 68 Ga-DOTA-RSA. Three ACI rats were imaged over 1 h by dynamic PET after intravenous administration of 15-25 MBq of 68 Ga-DOTA-RSA while the blood-pool activity was recorded simultaneously in a closed extracorporeal loop (ECL) between the carotid artery and the jugular vein. Time-activity curves (TACs) were obtained from volume of interest (VOI) analysis and from the ECL data. Stability and metabolites in plasma and urine were analyzed by size exclusion HPLC (SE-HPLC) 1 h after intravenous injection of 67 Ga-DOTA-RSA. Blood radioactivity decreased by 10% and 18% from 10 to 60 min p.i. by biodistribution and PET or ECL, respectively. Tissue sampling between 10 and 60 min p.i. showed slight increases in the uptake of spleen, myocardium, kidney and skeletal muscle while hepatic accretion remained unchanged. Total urinary excretion after 60 min amounted to 9% of the injected dose. HPLC demonstrated a single urinary metabolite corresponding in size to gallium-labeled DOTA. 68 Ga-DOTA-RSA is a blood-pool tracer whose physical and biological half-life is well suited for PET. Our findings support clinical imaging using 68 Ga-DOTA-labeled human serum albumin (HSA). The generator-produced label makes 68 Ga-DOTA-labeled albumin continuously available even to centers lacking an in-house cyclotron

  18. Relations between neuropsychological findings and lateral asymmetries of cerebral blood flow measured by SPECT in dementia of Alzheimer type

    International Nuclear Information System (INIS)

    Yoshimura, Nahoko; Soma, Yoshiaki; Ootsuki, Mika

    1993-01-01

    We studied 16 right-handed patients clinically diagnosed as dementia of Alzheimer type (6 men, 10 women; aged 63-85, mean 72.8 years). The average duration of symptoms was 2.7 years. Dementia ranged from mild to moderately severe. None had clinical or laboratory evidence of cerebrovascular disease (Hachinski ischemic scores for all patients were 4 or below 4). All received the Wechsler Adult Intelligence Scale (WAIS), Mini-mental State Test (MMS) and Western Aphasia Battery (WAB, First Japanese edition, 1986). Regional cerebral blood flow (rCBF) was evaluated by single photon emission CT (SPECT) with 123 I-N-isopropyl-p-iodoamphetamine ( 123 I-IMP), using the Matsuda's quantitative method. Regional tracer uptake was measured in regions of interests (ROIs) over right and left frontal, temporal, parietal and occipital cortical regions; basal ganglia; and cerebellar hemispheres. The subjects were divided into three groups on the basis of lateral asymmetries in the temporal and parietal cortexes of rCBF (left< right, n=5; right< left, n=3; left=right, n=8). We decided that lateral asymmetry was present when rCBF for each ROI between left and right sides differs by more than 10%. General score (MMS, T-IQ) was not correlated with asymmetry of cerebral blood flow. Verbal IQ in patients with predominant hypoperfusion of left temporal and parietal lobe was significantly lower than other group, while performance IQ and WAB constructive scores were lower in those with right hemispheric hypoperfusion (p<0.05). We concluded that cerebral blood flow asymmetry by SPECT was related significantly to the deficit of language and constructive function in patients with dementia of Alzheimer type. Decreased rCBF in the left temporoparietal lobe was associated with language dysfunction, and that in the right hemisphere, with constructive dysfunction. (author)

  19. Relations between neuropsychological findings and lateral asymmetries of cerebral blood flow measured by SPECT in dementia of Alzheimer type

    Energy Technology Data Exchange (ETDEWEB)

    Yoshimura, Nahoko; Soma, Yoshiaki; Ootsuki, Mika [Takeda General Hospital, Aizu-Wakamatsu, Fukushima (Japan)

    1993-10-01

    We studied 16 right-handed patients clinically diagnosed as dementia of Alzheimer type (6 men, 10 women; aged 63-85, mean 72.8 years). The average duration of symptoms was 2.7 years. Dementia ranged from mild to moderately severe. None had clinical or laboratory evidence of cerebrovascular disease (Hachinski ischemic scores for all patients were 4 or below 4). All received the Wechsler Adult Intelligence Scale (WAIS), Mini-mental State Test (MMS) and Western Aphasia Battery (WAB, First Japanese edition, 1986). Regional cerebral blood flow (rCBF) was evaluated by single photon emission CT (SPECT) with {sup 123}I-N-isopropyl-p-iodoamphetamine ({sup 123}I-IMP), using the Matsuda`s quantitative method. Regional tracer uptake was measured in regions of interests (ROIs) over right and left frontal, temporal, parietal and occipital cortical regions; basal ganglia; and cerebellar hemispheres. The subjects were divided into three groups on the basis of lateral asymmetries in the temporal and parietal cortexes of rCBF (leftblood flow. Verbal IQ in patients with predominant hypoperfusion of left temporal and parietal lobe was significantly lower than other group, while performance IQ and WAB constructive scores were lower in those with right hemispheric hypoperfusion (p<0.05). We concluded that cerebral blood flow asymmetry by SPECT was related significantly to the deficit of language and constructive function in patients with dementia of Alzheimer type. Decreased rCBF in the left temporoparietal lobe was associated with language dysfunction, and that in the right hemisphere, with constructive dysfunction. (author).

  20. Effects of scatter correction on regional distribution of cerebral blood flow using I-123-IMP and SPECT

    International Nuclear Information System (INIS)

    Ito, Hiroshi; Iida, Hidehiro; Kinoshita, Toshibumi; Hatazawa, Jun; Okudera, Toshio; Uemura, Kazuo

    1999-01-01

    The transmission dependent convolution subtraction method which is one of the methods for scatter correction of SPECT was applied to the assessment of CBF using SPECT and I-123-IMP. The effects of scatter correction on regional distribution of CBF were evaluated on a pixel by pixel basis by means of an anatomic standardization technique. SPECT scan was performed on six healthy men. Image reconstruction was carried out with and without the scatter correction. All reconstructed images were globally normalized for the radioactivity of each pixel, and transformed into a standard brain anatomy. After anatomic standardization, the average SPECT images were calculated for scatter corrected and uncorrected groups, and these groups were compared on pixel by pixel basis. In the scatter uncorrected group, a significant overestimation of CBF was observed in the deep cerebral white matter, pons, thalamus, putamen, hippocampal region and cingulate gyrus as compared with scatter corrected group. A significant underestimation was observed in all neocortical regions, especially in the occipital and parietal lobes, and the cerebellar cortex. The regional distribution of CBF obtained by scatter corrected SPECT was similar to that obtained by O-15 water PET. The scatter correction is needed for the assessment of CBF using SPECT. (author)

  1. 1-123 iodoamphetamine SPECT findings in paranoid schizophrenia

    International Nuclear Information System (INIS)

    Simon, T.R.; Walker, B.S.; Matthieson, S.; Miller, C.D.; Raese, J.

    1989-01-01

    To find out if frontal metabolic and cerebral blood flow differ between normal subjects and patients with paranoid schizophrenia (PAR), the authors have examined regional synaptic amine metabolism. Using [I- 123]iodoamphetamine (IMP), the authors compared 85 subjects (61 PAR patients and 24 normal subjects) with single-head single-photon emission CT (SPECT). Virtually automatic analysis assigned relative tracer uptake to the frontal, anterior temporoparietal (TP), and posterior TP regions. Consistent with the visual inspection of two clinicians familiar with SPECT IMP images, this objective method yielded T-tests that showed higher relative frontal lobe ratios in normal subjects than in PAR patients (P =.03)

  2. Technetium-99mTc-HMPAO brain SPECT in antiphospholipid syndrome - preliminary data

    International Nuclear Information System (INIS)

    Romanowicz, G.; Lass, P.; Koseda-Dragan, M.; Nowicki, R.; Krajka-Lauer, J.

    2000-01-01

    Background: Antiphospholipid syndrome (APS) is defined as the presence of repeated episodes of arterial or venous thrombosis, recurrent spontaneous abortions and throbocytopenia in patients with elevated antiphospholipid antibodies. An important feature of APS are cerebrovascular disorders of thrombotic origin. The aim of the study was to assess cerebral blood flow changes utilising brain SPECT HMPAO scanning. METHODS: Brain SPECT 99mTc-HMPAO scanning was performed in 20 patients with APS: 12 with systemic lupus erythematosus, 4 with Sneddon's syndrome, 2 with Sjoegren's syndrome, 2 with primary APS. 30 healthy volunteers served as a control group. RESULTS: 19 studies were abnormal, 1 normal. Abnormalities consisted of multifocal perfusion deficits and diffuse decrease of regional blood flow. The average number of focal perfusion deficits was 4.8±1.7. In 7 patients diffuse hypoperfusion of frontal lobes was seen, in 1 patient additionally hypoperfusion of temporal and occipital lobes. There was a correlation between the number of focal perfusion deficits and cognitive impairment in this group of patients. Correlation between SPECT images and clinical data was moderate in cerebellar syndrome and paresis, weak in persistent headache and vertigo. CONCLUSIONS: Those results indicate the high utility of CBF brain SPECT scanning in antiphospholipid syndrome. (author)

  3. Sequential assessment of regional cerebral blood flow, regional cerebral blood volume, and blood-brain barrier in focal cerebral ischemia: a case report

    International Nuclear Information System (INIS)

    Di Piero, V.; Perani, D.; Savi, A.; Gerundini, P.; Lenzi, G.L.; Fazio, F.

    1986-01-01

    Regional CBF (rCBF) and regional cerebral blood volume (rCBV) were evaluated by N,N,N'-trimethyl-N'-(2)-hydroxy-3-methyl-5-[123I]iodobenzyl-1, 3-propanediamine-2 HCl- and /sup 99m/TC-labeled red blood cells, respectively, and single-photon emission computerized tomography (SPECT) in a patient with focal cerebral ischemia. Sequential transmission computerized tomography (TCT) and SPECT functional data were compared with clinical findings to monitor the pathophysiological events occurring in stroke. A lack of correlation between rCBF-rCBV distributions and blood-brain barrier (BBB) breakdown was found in the acute phase. In the face of more prolonged alteration of BBB, as seen by TCT enhancement, a rapid evolution of transient phenomena such as luxury perfusion was shown by SPECT studies. Follow-up of the patient demonstrated a correlation between the neurological recovery and a parallel relative improvement of the cerebral perfusion

  4. Anatomically standardized statistical mapping of 123I-IMP SPECT in brain tumors

    International Nuclear Information System (INIS)

    Shibata, Yasushi; Akimoto, Manabu; Matsushita, Akira; Yamamoto, Tetsuya; Takano, Shingo; Matsumura, Akira

    2010-01-01

    123 I-iodoamphetamine Single Photon Emission Computed Tomography (IMP SPECT) is used to evaluate cerebral blood flow. However, application of IMP SPECT to patients with brain tumors has been rarely reported. Primary central nervous system lymphoma (PCNSL) is a rare tumor that shows delayed IMP uptake. The relatively low spatial resolution of SPECT is a clinical problem in diagnosing brain tumors. We examined anatomically standardized statistical mapping of IMP SPECT in patients with brain lesions. This study included 49 IMP SPECT images for 49 patients with brain lesions: 20 PCNSL, 1 Burkitt's lymphoma, 14 glioma, 4 other tumor, 7 inflammatory disease and 3 without any pathological diagnosis but a clinical diagnosis of PCNSL. After intravenous injection of 222 MBq of 123 I-IMP, early (15 minutes) and delayed (4 hours) images were acquired using a multi-detector SPECT machine. All SPECT data were transferred to a newly developed software program iNeurostat+ (Nihon Medi-physics). SPECT data were anatomically standardized on normal brain images. Regions of increased uptake of IMP were statistically mapped on the tomographic images of normal brain. Eighteen patients showed high uptake in the delayed IMP SPECT images (16 PCNSL, 2 unknown). Other tumor or diseases did not show high uptake of delayed IMP SPECT, so there were no false positives. Four patients with pathologically proven PCNSL showed no uptake in original IMP SPECT. These tumors were too small to detect in IMP SPECT. However, statistical mapping revealed IMP uptake in 18 of 20 pathologically verified PCNSL patients. A heterogeneous IMP uptake was seen in homogenous tumors in MRI. For patients with a hot IMP uptake, statistical mapping showed clearer uptake. IMP SPECT is a sensitive test to diagnose of PCNSL, although it produced false negative results for small posterior fossa tumor. Anatomically standardized statistical mapping is therefore considered to be a useful method for improving the diagnostic

  5. Neuropharmacological studies with SPECT in neuropsychiatric disorders

    International Nuclear Information System (INIS)

    Heinz, Andreas; Jones, Douglas W.; Raedler, Thomas; Coppola, Richard; Knable, Michael B.; Weinberger, Daniel R.

    2000-01-01

    The last decade saw a rapid development of single photon emission computed tomography (SPECT) from a tool to assess cerebral blood flow to the study of specific neurotransmitter systems. Because of the relatively long half-life of SPECT radioisotopes, it is practical to measure the availability of neuroreceptors and transporters in conditions approaching equilibrium. The cost-efficiency of SPECT allowed studies in relatively large samples of patients with various neuropsychiatric disorders. We have applied this approach in studies of dopaminergic, serotonergic, and muscarinergic neurotransmission in patients with dementia, extrapyramidal disorders, schizophrenia, and alcoholism. No simple associations were observed between a single defect in one neurotransmitter system and a certain neuropsychiatric disease. Instead, complex dysfunction of several neurotransmitter systems in multiple, partially connected brain circuits have been implicated. Treatment effects also have been characterized. Microdialysis and neurotransmitter depletion studies showed that most radioligands and endogenous neurotransmitters compete for binding at receptors and transporters. Future research directions include the assessment of endogenous neurotransmitter concentrations measured by depletion studies and of genetic effects on neuroreceptor and transporter expression

  6. Neuropharmacological studies with SPECT in neuropsychiatric disorders

    Energy Technology Data Exchange (ETDEWEB)

    Heinz, Andreas; Jones, Douglas W.; Raedler, Thomas; Coppola, Richard; Knable, Michael B.; Weinberger, Daniel R. E-mail: weinberd@intra.nimh.nih.gov

    2000-10-01

    The last decade saw a rapid development of single photon emission computed tomography (SPECT) from a tool to assess cerebral blood flow to the study of specific neurotransmitter systems. Because of the relatively long half-life of SPECT radioisotopes, it is practical to measure the availability of neuroreceptors and transporters in conditions approaching equilibrium. The cost-efficiency of SPECT allowed studies in relatively large samples of patients with various neuropsychiatric disorders. We have applied this approach in studies of dopaminergic, serotonergic, and muscarinergic neurotransmission in patients with dementia, extrapyramidal disorders, schizophrenia, and alcoholism. No simple associations were observed between a single defect in one neurotransmitter system and a certain neuropsychiatric disease. Instead, complex dysfunction of several neurotransmitter systems in multiple, partially connected brain circuits have been implicated. Treatment effects also have been characterized. Microdialysis and neurotransmitter depletion studies showed that most radioligands and endogenous neurotransmitters compete for binding at receptors and transporters. Future research directions include the assessment of endogenous neurotransmitter concentrations measured by depletion studies and of genetic effects on neuroreceptor and transporter expression.

  7. Development of Tc-99m-DTPA-HSA as a new blood pool scanning agent

    Energy Technology Data Exchange (ETDEWEB)

    Shirakami, Y; Matsumoto, Y; Yamauchi, Y; Kurami, M; Ueda, N; Hazue, M

    1987-04-01

    A new HSA preparation, Tc-99m-DTPA-HSA, was developed as a blood pool scanning agent. It shows higher labeling yield (more than 95 %) and higher blood retention (74.7 % I.D. at 1 hour post-injection) than Tc-99m-HSA prepared by directly labeling of HSA with Tc-99m. The introduction of DTPA, a strong bifunctional chelating agent, to HSA provides sites for the stable binding of Tc-99m. The preparation composed of 20 mCi of Tc-99m at calibration time and 10 mg of DTPA-HSA in a vial. After labeling, it had been stable for 24 hours at room temperature. In rats, most of Tc-99m-DTPA-HSA injected was metabolized and excreted in urine and feces. The cumulative radioactivity in urine and feces were 56.0 % and 13.7 % of injected dose, respectively, at 48 hours after injection. Metabolites observed in urine were Tc-99m-urea, Tc-99m-DTPA, reduced Tc-99m and so on. Tc-99m-DTPA-HSA proved, thus, a desirable feature for the blood pool scanning agent.

  8. Diagnosis of an isolated occult fracture of the posterior margin of the tibia with the SPECT/CT; Diagnostic d'une fracture occulte isolee de la marge posterieure du tibia par la TEMP-TDM

    Energy Technology Data Exchange (ETDEWEB)

    Bourdon, A.; Granier, P.; Mourad, M. [Centre Hospitalier de Carcassonne Antoine-Gayraud, Service de Medecine Nucleaire, 11 - Carcassonne (France)

    2007-12-15

    We report the case of a 56-year-old woman, investigated for pains of the right ankle related to a trauma of an unspecified mechanism. The radiographic assessment was negative. The {sup 99m}Tc-HDP 3-phase bone scintigraphy highlighted, on the blood pool and the delayed images, a located lesion on the right ankle. The single photon emission computerized tomography guided by computerized tomography (SPECT-CT) showed a focused uptake on the posterior margin of the right tibia and a sharp lucent line within the tomo-scintigraphy spot of uptake. The diagnosis accepted was an isolated occult fracture of the posterior margin of the right tibia. The contribution of the {sup 99m}Tc-HDP 3-phase bone scintigraphy combined with the SPECT-CT in the diagnosis of the occult fractures is discussed. (N.C.)

  9. Gated blood-pool SPECT assessment of Wolff-Parkinson-White syndromes before and after radiofrequency ablation of accessory pathways

    International Nuclear Information System (INIS)

    Bontemps, L.; Ben Brahim, H.; Kraiem, T.; Chevalier, P.; Kirkorian, G.; Touboul, P.; Itti, R.

    1997-01-01

    Radiofrequency (RF) ablation of accessory pathways in Wolff-Parkinson-White (WPW) syndrome is supposed to be less aggressive than fulguration while providing excellent results. The aims of our study were therefore the evaluation of the functional results of this therapy in terms of left or right ejection fractions and its effects on the contraction synchronism between both ventricular chambers, derived from bi-ventricular Fourier phase histograms. A consecutive series of 44 patients has been investigated within 48 hours before and after RF therapy: 14 patients had right sided WPW and 30 patients left sided WPW. Only patients for whom RF treatment was considered as a success have been included in the study. Gated blood pool tomography has been performed in order to localize the site of pre-excitation and to build-up the phase histograms for both ventricles, and planar gated imaging has been used for right and left ejection fraction determination. Functional results demonstrate the absence of deleterious effect of RF on ventricular contraction and rather a slight increase of ejection fractions, with a more statistically significant difference for left WPW (LVEF = 62.2 % before RF vs 64.4 % after RF; p = 0.02) than for right WPW (RVEF = 36.3 % before RF vs 39.7 after RF; p = 0.16). Phase analysis, on the contrary, show only significant differences for right WPW, with a noticeable decrease of the pre-excitation (left-to-right phase difference 14.4 deg before RF vs 7.5 deg after RF; p = 0.03) and a significant reduction of the right ventricular phase dispersion (right phase standard deviation 26.5 deg before RF vs 19.0 deg after RF; p = 0.03). For left WPW no measurable differences can be demonstrated in the basal state and it is suggested to use stimulation techniques in order to enhance the competition between the normal and accessory conduction pathways. (authors)

  10. Gated cardiac blood pool studies in atrial fibrillation: Role of cycle length windowing

    Energy Technology Data Exchange (ETDEWEB)

    Wallis, J W; Juni, J E; Wu, L [Michigan Univ., Ann Arbor (USA). Div. of Nuclear Medicine

    1991-01-01

    Cycle length windowing is gaining increasing acceptance in gated blood pool imaging of patients with atrial fibrillation (AF). The goals of this study were: to assess differences of ejection fraction (EF) in AF with and without windowing and to determine how EF varied with cycle length in patients with AF. Twenty patients with AF were prospectively studied by gated blood pool imaging, with simultaneous collection in each patient of 5-7 studies with cycle length windows spanning the cycle length histogram. Each window accepted beats of only a narrow range of cycle lengths. EF was determined for each of the narrow cycle length windows as well as for the entire gated blood pool study without cycle length windowing. For every patient an average of the windowed EFs was compared with the non-windowed EF. EF values were similar (mean windowed: 46.6; non-windowed: 45.5; P=0.16), and there was a good correlation between the two techniques (r=0.97). The data were then examined for a relationship of EF with cycle length. The difference from average windowed EF ({Delta}EF) was calculated for each window and plotted vs. the cycle length of the center of each window. No predictable linear or nonlinear relationship of {Delta}EF with window position was observed. Lack of predictable variation of EF with cycle length is likely due to lack of a predictable amount of ventricular filling for a given cycle length, as the amount of diastolic filling in AF depends on the random cycle length of the preceding beat. In summary, windowing in AF does not provide a clinically significant difference in EF determination. If cycle length windowing is used, the exact location of the window is not critical. (orig.).

  11. Molecular imaging agents for SPECT (and SPECT/CT)

    International Nuclear Information System (INIS)

    Gnanasegaran, Gopinath; Ballinger, James R.

    2014-01-01

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  12. Molecular imaging agents for SPECT (and SPECT/CT)

    Energy Technology Data Exchange (ETDEWEB)

    Gnanasegaran, Gopinath [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); Ballinger, James R. [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom)

    2014-05-15

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  13. Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols

    Energy Technology Data Exchange (ETDEWEB)

    Verger, Antoine; Karcher, Gilles [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); INSERM U947, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Djaballah, Wassila [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); INSERM U947, Nancy (France); Fourquet, Nicolas [Clinique Pasteur, Toulouse (France); Rouzet, Francois; Le Guludec, Dominique [AP-HP, Hopital Bichat, Department of Nuclear Medicine, Paris (France); INSERM U 773 Inserm and Denis Diderot University, Paris (France); Koehl, Gregoire; Roch, Veronique [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Imbert, Laetitia [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Centre Alexis Vautrin, Department of Radiotherapy, Vandoeuvre (France); Poussier, Sylvain [INSERM U947, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Fay, Renaud [INSERM, Centre d' Investigation Clinique CIC-P 9501, Nancy (France); Marie, Pierre-Yves [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); INSERM U961, Nancy (France); Hopital de Brabois, CHU-Nancy, Medecine Nucleaire, Vandoeuvre-les-Nancy (France)

    2013-03-15

    The results of stress myocardial perfusion SPECT could be enhanced by new cadmium-zinc-telluride (CZT) cameras, although differences compared to the results with conventional Anger cameras remain poorly known for most study protocols. This study was aimed at comparing the results of CZT and Anger SPECT according to various study protocols while taking into account the influence of obesity. The study population, which was from three different institutions equipped with identical CZT cameras, comprised 276 patients referred for study using protocols involving {sup 201}Tl (n = 120) or {sup 99m}Tc-sestamibi injected at low dose at stress ({sup 99m}Tc-Low; stress/rest 1-day protocol; n = 110) or at high dose at stress ({sup 99m}Tc-High; rest/stress 1-day or 2-day protocol; n = 46). Each Anger SPECT scan was followed by a high-speed CZT SPECT scan (2 to 4 min). Agreement rates between CZT and Anger SPECT were good irrespective of the study protocol (for abnormal SPECT, {sup 201}Tl 92 %, {sup 99m}Tc-Low 86 %, {sup 99m}Tc-High 98 %), although quality scores were much higher for CZT SPECT with all study protocols. Overall correlations were high for the extent of myocardial infarction (r = 0.80) and a little lower for ischaemic areas (r = 0.72), the latter being larger on Anger SPECT (p < 0.001). This larger extent was mainly observed in 50 obese patients who were in the {sup 201}Tl or {sup 99m}Tc-Low group and in whom stress myocardial counts were particularly low with Anger SPECT (228 {+-} 101 kcounts) and dramatically enhanced with CZT SPECT (+279 {+-} 251 %). Concordance between the results of CZT and Anger SPECT is good regardless of study protocol and especially when excluding obese patients who have low-count Anger SPECT and for whom myocardial counts are dramatically enhanced on CZT SPECT. (orig.)

  14. Single-Photon Emission Computerized Tomography (SPECT in Neuropsychiatry: A Review

    Directory of Open Access Journals (Sweden)

    B. K. Puri

    1992-01-01

    Full Text Available Cranial single-photon emission computerized tomography (SPECT or SPET can now give regional cerebral blood flow images with a resolution approaching that of positron emission tomography (PET. In this paper, the use of high resolution SPECT neuroimaging in neuropsychiatric disorders, including Alzheimer's disease, multi-infarct dementia, Pick's disease, progressive supranuclear palsy, Korsakoff's psychosis, Creutzfeld-Jakob disease, Parkinson's disease, Huntington's disease, schizophrenia, mood disorders, obsessive–compulsive disorder, HIV infection and AIDS is reviewed. Finally, further potential research and clinical uses, based on ligand studies, are outlined.

  15. The values of myocardial tomography imaging and gated cardiac blood pool imaging in detecting left ventricular aneurysm

    International Nuclear Information System (INIS)

    Zhu Mei; Pan Zhongyun; Li Jinhui

    1992-01-01

    The sensitivity and specificity of myocardial tomography imaging and gated cardiac blood-pool imaging in detecting LVA were studied in 36 normal subjects and 68 patients with myocardial infarction. The sensitivities of exercise and rest myocardial imaging in detecting LVA were 85% and 77.3% respectively. The specificity of both is 95.5%. The sensitivity of cinema display, phase analysis and left ventricular phase shift in evaluating LVA were 86.7%, 86.7%, 100% respectively. Their specificity were all 100%. It is concluded that blood pool imaging is of choice for the diagnosis of LVA, and that myocardial imaging could also demonstrate LVA during diagnosing myocardial infarction

  16. Regional cerebral blood flow in vascular depression assessed by 123I-IMP SPECT

    International Nuclear Information System (INIS)

    Kimura, Mahito; Shimoda, Kengo; Mizumura, Sunao; Tateno, Amane; Fujito, Tatsuma; Mori, Takao; Endo, Shunkichi

    2003-01-01

    As the prevalence of white matter hyperintensities detected on T2 weighted MRI scans in patients with late-onset depression is higher than that in nondepressed patients, the concept of ''vascular depression'' (VDep) was introduced in 1997. However, the pathology of vascular depression has not been clarified. This study examined the differences in functional imaging between vascular and non-vascular depression (non-VDep). We utilized 123 I-IMP single photon emission computed tomography (SPECT) to compare regional cerebral blood flows (rCBF) between 9 patients with VDep (Krishnan criteria) and 11 age- and sex-matched patients with non-VDep in both depressed and remitted states. In both VDep and non-VDep patients, mean rCBF increased significantly as depression improved, partially aided by changes in left anterior temporal blood flow. In addition, compared to non-VDep patients, the left anterior frontal rCBF for VDep patients was significantly lower in both depressed and remitted states. Left anterior temporal rCBF therefore appears to represent a state marker that increases as symptoms associated with late-onset depression improve, regardless of vascular changes. Furthermore, in VDep patients, left anterior frontal rCBF was low in both states compared to non-VDep patients, and might not only represent a trait marker, but also correlated with the duration of disease and likelihood of recurrence and relapse. (author)

  17. Evaluation of Tl-201 SPECT imaging findings in prostate cancer

    Directory of Open Access Journals (Sweden)

    Sinem Ozyurt

    2015-07-01

    Full Text Available Objectives: To compare with histopathological findings the findings of prostate cancer imaging by SPECT method using Tl-201 as a tumor seeking agent. Methods: The study comprised 59 patients (age range 51-79 years, mean age 65.3 ± 6.8 years who were planned to have transrectal ultrasonography (TRUS-guided biopsies due to suspicion of prostate cancer between April 2011 and September 2011. Early planar, late planar and SPECT images were obtained for all patients. Scintigraphic evaluation was made in relation to uptake presence and patterns in the visual assessment and to Tumor/Background (T/Bg ratios for both planar and SPECT images in the quantitative assessment. Histopathological findings were compatible with benign etiology in 36 (61% patients and malign etiology in 23 (39% patients. Additionally, comparisons were made to evaluate the relationships between uptake patterns,total PSA values and Gleason scores. Results: A statistically significant difference was found between the benign and malignant groups in terms of uptake in planar and SPECT images and T/Bg ratios and PSA values. No statistically significant difference was found between uptake patterns of planar and SPECT images and Gleason scores in the malignant group. Conclusions: SPECT images were superior to planar images in the comparative assessment. Tl-201 SPECT imaging can provide an additional contribution to clinical practice in the diagnosis of prostate cancer and it can be used in selected patients.

  18. Ventricular function during the acute rejection of heterotopic transplanted heart: Gated blood pool studies

    International Nuclear Information System (INIS)

    Valette, H.; Bourguignon, M.H.; Desruennes, M.; Merlet, P.; Le Guludec, D.; Syrota, A.

    1991-01-01

    Twenty patients who had undergone a heterotopic heart transplant were studied prospectively to determine the relationship between rejection and ventricular dysfunction assessed from gated blood pool studies. A fully automated method for detecting ventricular edges was implemented; its success rate for the grafted left and right ventricles was 94% and 77%, respectively. The parameters, peak ejection and filling rates, were calculated pixel per pixel using a two-harmonic Fourier algorithm and then averaged over the ventricular region of interest. Peak filling and ejection rates were closely related with the severity of the rejection, while the left ventricular ejection fraction was not. Peak filling rates of both ventricles were the indices closely related to the presence of moderate rejection. Despite the low number of patients, these data suggested that gated blood pool derived indices of ventricular function are associated with ventricular dysfunction resulting from myocarditis rejection. Radionuclide ventriculography provides parametric data which are accurate and reliable for the diagnosis of rejection. (orig.)

  19. Investigation of regional cerebral blood flow in alcoholic Korsakoff`s syndrome with {sup 123}I-IMP SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Makoto; Nomura, Soichiro [Tachikawa Hospital, Tokyo (Japan); Kato, Motoichiro; Nakazawa, Tsuneyuki

    1995-05-01

    Regional cerebral blood flow (rCBF) was determined quantitatively by single photon emission computed tomography (SPECT) using N-isopropyl-p-[{sup 123}I]iodoamphetamine ({sup 123}I-IMP) in 6 patients with alcoholic Korsakoff`s syndrome (A group). The findings were compared with concurrently available findings from 6 alcoholic patients with no evidence of cerebral disordres such as Korsakoff`s syndrome and dementia (B group) and 4 healthy persons (C group). In both A and B groups, diffuse decrease in blood flow was significantly observed in the entire brain, as compared with the C group; no significant difference in the decreased blood flow existed between the A and B groups. According to the WAIS results, the patients in the A group were classified as `typical Korsakoff`s syndrome` (full IQ of 90 or more) and as `serious Korsakoff`s syndrome` (full IQ of 89 or less). rCBF in the thalamus was significantly lower in the A group of patients with typical Korsakoff`s syndrome than the B group. These findings may reflect the variety of alcoholic Korsakoff`s syndrome. This may also have an implication for the possible classification of several types in this syndrome. (N.K.).

  20. Evaluation of the vascular state of hepatic tumor with radioisotope angiography and blood pool scintigraphies (early and delayed)

    International Nuclear Information System (INIS)

    Aburano, Tamio; Tonami, Norihisa; Hisada, Kinichi

    1976-01-01

    Combined radioisotope examinations of hepatic tumors have been performed using α 1 -fetoprotein radioimmunoassay, radioisotope angiography of the liver, and some tumor positive imaging scintigraphies. However, with these methods, it is frequently impossible to differentiate metastatic cancers from benign focal lesions. Radioisotope angiography of the liver, and both early (5 min later)- and delayed (4 hours later) blood pool scintigraphies of the liver were done continuously after 10mCi of sup(99m)Tc-albumin intravenous injection, in cases of clearcut focal lesions on sup(99m)Tc-colloid liver scan. The relationships among these findings were examined. Four of seven cases with hepatoma and two of nine cases with metastatic cancer which had showed hypervascular findings on radioisotope angiogram showed clear blood pool activities in the area of focal defects on sup(99m)Tc-colloid scan although less than liver. On the other hand, none of hypovascular tumors on radioisotope angiogram showed blood pool activities. However, four hours later, in most malignant lesions, the lesion to liver activity ratio calculated from data processing system showed a much higher value than the ratio obtained 5 min later after injection, although two cases with benign focal lesions did not show such sequential change. The sequential evaluation of the vascular state of a hepatic tumor using radioisotope angiography and early-and delayed blood pool scintigraphies was supposed to be extremely useful for the elucidation of the nature of focal hepatic lesions on sup(99m)Tc-colloid scan, especially in differentiating hypovascular malignant- and benign lesions. (auth.)

  1. Dynamic circular buffering: a technique for equilibrium gated blood pool imaging.

    Science.gov (United States)

    Vaquero, J J; Rahms, H; Green, M V; Del Pozo, F

    1996-03-01

    We have devised a software technique called "dynamic circular buffering" (DCB) with which we create a gated blood pool image sequence of the heart in real time using the best features of LIST and FRAME mode methods of acquisition/processing. The routine is based on the concept of independent "agents" acting on the timing and position data continuously written into the DCB. This approach allows efficient asynchronous operation on PC-type machines and enhanced capability on systems capable of true multiprocessing and multithreading.

  2. Quantitative Analysis of Regional Cerebral Blood Flow using 99mTc-HMPAO SPECT in Parkinson's Disease

    International Nuclear Information System (INIS)

    Lee, Myung Chul; Bae, Sang Kyun; Chung, June Key; Koh, Chang Soon; Roh, Jae Kyu; Myung, Ho Jin; Lee, Myung Hae

    1992-01-01

    Regional cerebral blood flow were measured in 10 patients with Parkinson's disease and 12 normal persons using 99m Tc-HMPAO SPECT. Reconstructed images were interpreted qualitatively and were compared with those findings of CT. For the quantitative analysis, six pairs of region of interest matched with the perfusion territories of large cerebral arteries and cerebellar hemisphere were determined. From the count values, indices showing the degree of asymmetry between right and left cerebral or cerebellar hemisphere, cerebral asymmetry index (ASI) and percent index of cerebellar asymmetry (PIA), and an index showing change of each region, region to cerebellum ratio (RCR) were obtained. ASI of normal persons and patients were 0.082 ± 0.033 and 0.108 ± 0.062, respectively and PIA were -0.4 ± 0.7% and -0.7 ± 1.0%, respectively, which showed no statistically significant difference between normal persons and patients. Among 10 RCR's, those of both regions of basal ganglia and both regions of anterior cerebral artery were significantly reduced. We concluded that the most significant reduction of regional cerebral blood flow in patients with Parkinson's disease was observed in the regions of basal ganglia and in the regions of anterior cerebral artery, and the degree of change in hemispheric blood flow was similar in both hemisphere.

  3. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    Energy Technology Data Exchange (ETDEWEB)

    Golestani, Reza; Dierckx, Rudi A.J.O. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Wu, Chao [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Tio, Rene A. [University Medical Center Groningen, Thorax Center, Department of Cardiology, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Zeebregts, Clark J. [University Medical Center Groningen, Department of Surgery, Division of Vascular Surgery, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Petrov, Artiom D. [University of California, Irvine, Division of Cardiology, School of Medicine, Irvine, California (United States); Beekman, Freek J. [University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Delft University of Technology, Faculty of Applied Sciences, Section Radiation Detection and Medical Imaging, Delft (Netherlands); MILabs, Utrecht (Netherlands); Boersma, Hendrikus H. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Department of Clinical and Hospital Pharmacy, Hanzeplein 1, P.O. Box 30001, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Slart, Riemer H.J.A. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands)

    2010-09-15

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  4. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    International Nuclear Information System (INIS)

    Golestani, Reza; Dierckx, Rudi A.J.O.; Wu, Chao; Tio, Rene A.; Zeebregts, Clark J.; Petrov, Artiom D.; Beekman, Freek J.; Boersma, Hendrikus H.; Slart, Riemer H.J.A.

    2010-01-01

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  5. Head-to-Head Visual Comparison between Brain Perfusion SPECT and Arterial Spin-Labeling MRI with Different Postlabeling Delays in Alzheimer Disease.

    Science.gov (United States)

    Kaneta, T; Katsuse, O; Hirano, T; Ogawa, M; Yoshida, K; Odawara, T; Hirayasu, Y; Inoue, T

    2017-08-01

    Arterial spin-labeling MR imaging has been recently developed as a noninvasive technique with magnetically labeled arterial blood water as an endogenous contrast medium for the evaluation of CBF. Our aim was to compare arterial spin-labeling MR imaging and SPECT in the visual assessment of CBF in patients with Alzheimer disease. In 33 patients with Alzheimer disease or mild cognitive impairment due to Alzheimer disease, CBF images were obtained by using both arterial spin-labeling-MR imaging with a postlabeling delay of 1.5 seconds and 2.5 seconds (PLD 1.5 and PLD 2.5 , respectively) and brain perfusion SPECT. Twenty-two brain regions were visually assessed, and the diagnostic confidence of Alzheimer disease was recorded. Among all arterial spin-labeling images, 84.9% of PLD 1.5 and 9% of PLD 2.5 images showed the typical pattern of advanced Alzheimer disease (ie, decreased CBF in the bilateral parietal, temporal, and frontal lobes). PLD 1.5 , PLD 2.5 , and SPECT imaging resulted in obviously different visual assessments. PLD 1.5 showed a broad decrease in CBF, which could have been due to an early perfusion. In contrast, PLD 2.5 did not appear to be influenced by an early perfusion but showed fewer pathologic findings than SPECT. The distinctions observed by us should be carefully considered in the visual assessments of Alzheimer disease. Further studies are required to define the patterns of change in arterial spin-labeling-MR imaging associated with Alzheimer disease. © 2017 by American Journal of Neuroradiology.

  6. The characteristics of SPECT images in childhood benign partial epilepsy

    International Nuclear Information System (INIS)

    Jia Shaowei; Liao Jianxiang; Liu Xiaoyan; Zheng Xiyuan; Qin Jiong; Pan Zhongyun; Zuo Qihua

    1998-01-01

    Purpose: To investigate childhood benign partial epilepsy (BPE) with SPECT. Methods: Double SPECT imaging was performed on 21 cases of BPE at the stage of wake (interval spike discharge) and sleep (spike discharge), under EEG monitoring. The transverse images were reconstructed after digital image subtraction. The quantitative analysis was conducted with brain flow change rate (BFCR) % mathematical model. Results: EEG monitoring demonstrated approximately normal background of 21 cases of BPE during the stage of wake, and spike discharge frequency markedly increased during the stage of sleep, 117 foci were showed by SPeCT in cases of BPE, and the average was 5.6 +- 1.6 foci/case. The characteristics of SPECT transverse images were 1) multiple foci of mirror, 2) mostly seen in Rolandic region, 3) circular symbol, 4) the radioactivity in foci decreased during the stage of wake (interval spike discharge) and increased during the stage of sleep (spike discharge). The concordance of SPECT and EEG was 93.1% (109/117 foci). The BFCR% of all epileptogenic foci exceeded normal limit (99% confidence interval). There was no correlation between the spike discharge frequency and BFCR% (r = 0.45, P>0.05). Conclusions: Regional cerebral blood flow and function were abnormal during the epileptogenic foci were discharging abnormally in BPE

  7. Extraosseous accumulation of bone scanning agents in malignant brain tumors. Comparison to semi-quantitative evaluation with 99mTc SPECT/201Tl SPECT and histological findings

    International Nuclear Information System (INIS)

    Suzuki, Aya

    2003-01-01

    Although 201 Tl chloride (Tl) SPECT has been used in the differential diagnosis between recurrence of malignant brain tumor and necrosis after treatment, it is not generally recognized as a definite modality to distinguish them. We conducted a preliminary study using Tl SPECT and 99m Tc-MDP or 99m Tc-HMDP (Tc) SPECT because it has been said that extraosseous accumulation was caused by calcium deposits in necrotic tissues. In our study, for the purposes of clarifying the mechanism of extraosseous uptake and the correlation between extraosseous accumulation of bone-scanning agent and tumor viability in malignant brain tumors, we compared whether Tc uptake was correlated with the histopathological findings and further performed semi-quantitative evaluation between Tc SPECT and Tl SPECT. The correlation coefficients between the ratio of tumor to normal skull count obtained from Tc SPECT (Tc-T/N) and those of tumor to normal brain count (T/N) and to normal scalp count (T/S) both obtained from Tl SPECT were calculated. Using contrast enhanced CT (CE-CT) or contrast enhanced MRI (CE-MRI), 8 of 10 cases showed intensely ring-enhanced tumor with necrotic lesion. Histopathologically, 7 of 8 cases whose tumor had been resected before treatment had necrosis with increased vascularity or bleeding. Of the remaining 2 cases one case, malignant lymphoma had only hypervascularity by biopsy, while the other one was excluded for resection after treatment. Three of these 8 cases whose CE-CT or CE-MRI showed necrotic lesions exhibited Tc and Tl accumulations in the area corresponding to necrosis. In contrast, 2 showed no Tc nor Tl uptake. Tc-T/N had no significant correlation with any of early-, delayed-T/N or T/S. In conclusion, there was no significant correlation between Tc and Tl uptakes by malignant brain tumors in semi-quantitative evaluation. (author)

  8. The early diagnostic value of oral acetazolamide load combined with SPECT rCBF imaging in patients with transient ischemia attack in brain

    International Nuclear Information System (INIS)

    Liu Xintong; Zheng Zhiping; Qiao Suixian; Tang Anwu

    2001-01-01

    Objective: In order to assess the diagnostic value of acetazolamide (ACZ) combined with rCBF-SPECT imaging in patients with transient ischemia attack (TIA). Methods: SPECT imaging was performed before and after oral ACZ with visual and semiquantitative analysis of the images. Blood gas analysis was done before and after ACZ administration either. Results: After ACZ loading, in normal group, 99 Tc m -ECD was distributed symmetrically on correspondent parts of the brain and rCBF was generally increased. The blood pH was decreased and blood PCO 2 was increased, respectively in TIA group, the positive rate of hypoperfusion foci on SPECT images were increased from 5/6 to 6/6 in symptomatic patients and from 60% to 92% in asymptomatic patients. The total positive rate was 93%. Conclusion: Oral ACZ before SPECT imaging is a simple, reliable way for early diagnosis in patients with TIA

  9. Statistical parametric mapping of Tc-99m HMPAO SPECT cerebral perfusion in the normal elderly

    International Nuclear Information System (INIS)

    Turlakow, A.; Scott, A.M.; Berlangieri, S.U.; Sonkila, C.; Wardill, T.D.; Crowley, K.; Abbott, D.; Egan, G.F.; McKay, W.J.; Hughes, A.

    1998-01-01

    Full text: The clinical value of Tc-99m HMPAO SPECT cerebral blood flow studies in cognitive and neuropsychiatric disorders has been well described. Currently, interpretation of these studies relies on qualitative or semi- quantitative techniques. The aim of our study is to generate statistical measures of regional cerebral perfusion in the normal elderly using statistical parametric mapping (Friston et al, Wellcome Department of Cognitive Neurology, London, UK) in order to facilitate the objective analysis of cerebral blood flow studies in patient groups. A cohort of 20 healthy, elderly volunteers, aged 68 to 81 years, was prospectively selected on the basis of normal physical examination and neuropsychological testing. Subjects with risk factors, or a history of cognitive impairment were excluded from our study group. All volunteers underwent SPECT cerebral blood flow imaging, 30 minutes following the administration of 370 MBq Tc-99m HMPAO, on a Trionix Triad XLT triple-headed scanner (Trionix Research Laboratory Twinsburg, OH) using high resolution, fan-beam collimators resulting in a system resolution of 10 mm full width at half-maximum (FWHM). The SPECT cerebral blood flow studies were analysed using statistical parametric mapping (SPM) software specifically developed for the routine statistical analysis of functional neuroimaging data. The SPECT images were coregistered with each individual's T1-weighted MR volume brain scan and spatially normalized to standardised Talairach space. Using SPM, these data were analyzed for differences in interhemispheric regional cerebral blood flow. Significant asymmetry of cerebral perfusion was detected in the pre-central gyrus at the 95th percentile. In conclusion, the interpretation of cerebral blood flow studies in the elderly should take into account the statistically significant asymmetry in interhemispheric pre-central cortical blood flow. In the future, clinical studies will be compared to statistical data sets in age

  10. Statistical parametric mapping of Tc-99m HMPAO SPECT cerebral perfusion in the normal elderly

    Energy Technology Data Exchange (ETDEWEB)

    Turlakow, A.; Scott, A.M.; Berlangieri, S.U.; Sonkila, C.; Wardill, T.D.; Crowley, K.; Abbott, D.; Egan, G.F.; McKay, W.J.; Hughes, A. [Austin and Repatriation Medical Centre, Heidelberg, VIC (Australia). Departments of Nuclear Medicine and Centre for PET Neurology and Clinical Neuropsychology

    1998-06-01

    Full text: The clinical value of Tc-99m HMPAO SPECT cerebral blood flow studies in cognitive and neuropsychiatric disorders has been well described. Currently, interpretation of these studies relies on qualitative or semi- quantitative techniques. The aim of our study is to generate statistical measures of regional cerebral perfusion in the normal elderly using statistical parametric mapping (Friston et al, Wellcome Department of Cognitive Neurology, London, UK) in order to facilitate the objective analysis of cerebral blood flow studies in patient groups. A cohort of 20 healthy, elderly volunteers, aged 68 to 81 years, was prospectively selected on the basis of normal physical examination and neuropsychological testing. Subjects with risk factors, or a history of cognitive impairment were excluded from our study group. All volunteers underwent SPECT cerebral blood flow imaging, 30 minutes following the administration of 370 MBq Tc-99m HMPAO, on a Trionix Triad XLT triple-headed scanner (Trionix Research Laboratory Twinsburg, OH) using high resolution, fan-beam collimators resulting in a system resolution of 10 mm full width at half-maximum (FWHM). The SPECT cerebral blood flow studies were analysed using statistical parametric mapping (SPM) software specifically developed for the routine statistical analysis of functional neuroimaging data. The SPECT images were coregistered with each individual`s T1-weighted MR volume brain scan and spatially normalized to standardised Talairach space. Using SPM, these data were analyzed for differences in interhemispheric regional cerebral blood flow. Significant asymmetry of cerebral perfusion was detected in the pre-central gyrus at the 95th percentile. In conclusion, the interpretation of cerebral blood flow studies in the elderly should take into account the statistically significant asymmetry in interhemispheric pre-central cortical blood flow. In the future, clinical studies will be compared to statistical data sets in age

  11. Effects of cross talk on dual energy SPECT imaging between 123I-BMIPP and 201Tl

    International Nuclear Information System (INIS)

    Morita, Masato; Narita, Hitoshi; Yamamoto, Juro; Fukutake, Naoshige; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Fukuchi, Minoru

    1994-01-01

    The study was undertaken to determine how much cross talk influences the visual assessment of dual energy single photon emission computed tomographic (SPECT) images with iodine 123 beta-methyl-p-iodophenylpentadecanoic acid (I-123 BMIPP) and thallium-201 in 15 patients with acute myocardial infarction. After single SPECT with I-123 BMIPP was undertaken, simultaneous dual SPECT with I-123 BMIPP and Tl-201 were undertaken in all patients. Three patients also underwent single SPECT with Tl-201. I-123 BMIPP and Tl-201 uptake was graded in four-score for the comparison between single and dual SPECT images. There was good correlation between dual energy SPECT and both single I-123 BMIPP SPECT (pS=0.97) and single Tl-201 SPECT (pS=0.59). Uptake scores were increased on dual energy SPECT, compared with single I-123 SPECT (8 out of 132 segments) and single Tl-201 SPECT (12 out of 36 segments). Overall, there was a comparatively well correlation between single SEPCT with either I-123 BMIPP or Tl-201 and dual energy SPECT images. However, one tracer uptake sometimes increased in the other tracer defect areas. This was noticeable when I-123 BMIPP exerted an effect on Tl-201. (N.K.)

  12. Assessment of poststress left ventricular ejection fraction by gated SPECT: comparison with equilibrium radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Acampa, Wanda; Liuzzi, Raffaele; De Luca, Serena; Capasso, Enza; Luongo, Luca; Cuocolo, Alberto; Caprio, Maria Grazia; Nicolai, Emanuele; Petretta, Mario

    2010-01-01

    We compared left ventricular (LV) ejection fraction obtained by gated SPECT with that obtained by equilibrium radionuclide angiocardiography in a large cohort of patients. Within 1 week, 514 subjects with suspected or known coronary artery disease underwent same-day stress-rest 99m Tc-sestamibi gated SPECT and radionuclide angiocardiography. For both studies, data were acquired 30 min after completion of exercise and after 3 h rest. In the overall study population, a good correlation between ejection fraction measured by gated SPECT and by radionuclide angiocardiography was observed at rest (r=0.82, p<0.0001) and after stress (r=0.83, p<0.0001). In Bland-Altman analysis, the mean differences in ejection fraction (radionuclide angiocardiography minus gated SPECT) were -0.6% at rest and 1.7% after stress. In subjects with normal perfusion (n=362), a good correlation between ejection fraction measured by gated SPECT and by radionuclide angiocardiography was observed at rest (r=0.72, p<0.0001) and after stress (r=0.70, p<0.0001) and the mean differences in ejection fraction were -0.9% at rest and 1.4% after stress. Also in patients with abnormal perfusion (n=152), a good correlation between the two techniques was observed both at rest (r=0.89, p<0.0001) and after stress (r=0.90, p<0.0001) and the mean differences in ejection fraction were 0.1% at rest and 2.5% after stress. In a large study population, a good agreement was observed in the evaluation of LV ejection fraction between gated SPECT and radionuclide angiocardiography. However, in patients with perfusion abnormalities, a slight underestimation in poststress LV ejection fraction was observed using gated SPECT as compared to equilibrium radionuclide angiocardiography. (orig.)

  13. Usefulness of quantitative determination of cerebral blood flow by 123I-IMP SPECT reference sample method in various cerebrovascular disorders

    International Nuclear Information System (INIS)

    Fukuda, Tadaharu; Hasegawa, Kouichi; Yamanaka, Shigehito; Hasue, Masamichi; Ohtubo, Yutaka; Wada, Atsushi; Nakanishi, Hisashi; Nakamura, Tatuya; Itou, Hiroshi.

    1992-01-01

    Cerebral blood flow (CBF) was quantitatively determined by N-isopropyl-p-[ 123 I] iodo-amphetamine (IMP) single photon emission computed tomography (SPECT) with a rotating gamma camera. A ZLC 7500 unit (SIEMENS Inc.) was used for emission CT, and a SCINTIPAK-2400 (Shimadzu Corp. Ltd.) for data processing. For the quantitative determination of CBF, arterial blood samples were collected for 5 minutes during the intravenous injection of 111 MBq of IMP, and a reference sample method corrected by time-activity curve was used. The determination was carried out in 90 patients with various cerebrovascular diseases and 5 normal volunteers. Mean cerebral blood flow (m-CBF) in the normal cases as determined by the above method was 42.4±6.0 (ml/100g/min). In patients with acute phase subarachnoid hemorrhage (SAH), severity on CT was marked in patients with intracerebral hematomas greater than 45 mm in diameter. Patients with non-hemorrhagic arteriovenous malfomation (AVM) whose nidi were 30 mm or more in diameter showed a decrease in CBF on the afferent side. This decrease was caused by a steal phenomenon affecting CBF around the AVM. The size of cerebral infarction on CT was closely correlated with the decrease in CBF, and CBF in patients with stenosis and obstruction of the main trunks was less than that in patients without them. CBF was increased by 10-20% in patients who underwent carotid endarterectomy or superior temporal artery-middle cerebral artery anastomosis for obstruction or stenosis of the internal carotid artery or the middle cerebral artery. The quantitative determination of CBF by IMP SPECT reference sample method was useful for evaluating the morbid condition and estimating the prognosis of cerebrovascular diseases, and evaluating the effects of therapy. (J.P.N.)

  14. 99mTc-HMPAO SPECT in pediatric patients with neurological disorders

    International Nuclear Information System (INIS)

    Yamaoka, Mitsuko

    1994-01-01

    In 125 pediatric patients with suspected brain diseases, EEG, CT and MRI findings were compared with those obtained with single photon emission computed tomography (SPECT) of the brain using Tc-99m-d, 1-hexamethyl-propylene amine oxime ( 99m Tc-HMPAO), to determine the usefulness of SPECT as an adjunct to EEG, CT and MRI in this age group. The incidences of abnormal finding in the 125 patients were 53.6, 75.2, 60.6 and 51.4% using 99m Tc-HMPAO SPECT, EEG, CT and MRI respectively. In localization-related epilepsy and cerebrovascular diseases, the incidence of abnormality was higher with 99m Tc-HMPAO SPECT than with either CT or MRI. There was a tendency for mean age to be higher and mean IQ or DG lower in patients with more extensive abnormality in comparison to those who had normal or only focally abnormal SPECT findings. Nevertheless, some patients showed focal hypofusion in the frontal or occipital area without significant mental retardation. Epileptic foci detected by EEG corresponded to defects found using 99m Tc-HMPAO SPECT in 34.8% of the symptomatic localization-related epileptic patients. Pathological lesions detected by CT or MRI corresponded with SPECT findings in 48.1% of patients. Furthermore, the incidence of abnormal findings on SPECT was 30% in patients in whom CT or MRI was normal. Epileptic foci detected by EEG did not correspond well with the area of focal hyperfusion found on SPECT. Focal hyperfusion may sometimes occur even in the interictal period or postictal period in childhood seizure disorders. In conclusion, 99m Tc-HMPAO SPECT revealed abnormal findings at a moderate incidence in neuropediatric patients. Correlations with EEG, CT and MRI findings as well as assessment of clinical signs, including the investigation of epileptic foci, are essential for adequate interpretation of brain functions. (author)

  15. Performance of Myocardial Perfusion Imaging Using Multi-focus Fan Beam Collimator with Resolution Recovery Reconstruction in a Comparison with Conventional SPECT

    International Nuclear Information System (INIS)

    Matsutomo, Norikazu; Nagaki, Akio; Sasaki, Masayuki

    2014-01-01

    IQ-SPECT is an advanced high-speed SPECT modality for myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQ-SPECT with conventional SPECT in terms of performance, based on standard clinical protocols. In addition, we examined the concordance between conventional and IQ-SPECT in patients with coronary artery disease (CAD). Fifty-three patients, undergoing rest-gated MPI for the evaluation of known or suspected CAD, were enrolled in this study. In each patient, conventional SPECT ( 99m Tc-tetrofosmin, 9.6 min and 201 Tl, 12.9 min) was performed, immediately followed by IQ-SPECT, using a short acquisition time (4.3 min for 99m Tc-tetrofosmin and 6.2 min for 201 Tl). A quantitative analysis was performed on an MPI polar map, using a 20-segment model of the left ventricle. An automated analysis by gated SPECT was carried out to determine the left ventricular volume and function including end-diastolic volume (EDV), end-systolic volume (ESV), and left ventricular ejection fraction (LVEF). The degree of concordance between conventional SPECT and IQ-SPECT images was evaluated according to linear regression and Bland-Altman analyses. The segmental percent uptake exhibited a significant correlation between IQ-SPECT and conventional SPECT (P<0.05). The mean differences in 99m Tc-tetrofosmin studies were 1.1±6.6% (apex), 2.8±5.7% (anterior wall), 2.9±6.2% (septal wall), 4.9±6.7% (lateral wall), and 1.8±5.6% (inferior wall). Meanwhile, regarding the 201 Tl-SPECT studies, these values were 1.6±6.9%, 2.0±6.6%, 2.1±5.9%, 3.3±7.2%, and 2.4±5.8%, respectively. Although the mean LVEF in IQ-SPECT tended to be higher than that observed in conventional SPECT (conventional SPECT=64.8±11.8% and IQ-SPECT=68.3±12.1% for 99m Tc-tetrofosmin; conventional SPECT= 56.0±11.7% and IQ-SPECT=61.5±12.2% for 201 Tl), quantitative parameters were not significantly different between

  16. A case of Cotard syndrome: (123)I-IBZM SPECT imaging of striatal D(2) receptor binding.

    Science.gov (United States)

    De Risio, Sergio; De Rossi, Giuseppe; Sarchiapone, Marco; Camardese, Giovanni; Carli, Vladimir; Cuomo, Chiara; Satta, Maria Antonietta; Di Giuda, Daniela

    2004-01-15

    A case of 'dèlire de nègation' that suddenly appeared in a 43-year-old male is presented. No alteration in regional cerebral blood, as measured by (99m)Tc-HMPAO-SPECT, was found, but (123)I-IBZM-SPECT analysis showed reduced striatal D(2) receptor binding that further decreased after treatment.

  17. Prognostic value of normal stress-only myocardial perfusion imaging: a comparison between conventional and CZT-based SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yokota, Shu; Ottervanger, Jan Paul; Timmer, Jorik R. [Isala Hospital, Department of Cardiology, Zwolle (Netherlands); Mouden, Mohamed; Engbers, Elsemiek [Isala Hospital, Department of Cardiology, Zwolle (Netherlands); Isala Hospital, Department of Nuclear Medicine, Zwolle (Netherlands); Knollema, Siert; Jager, Pieter L. [Isala Hospital, Department of Nuclear Medicine, Zwolle (Netherlands)

    2016-02-15

    Single photon emission computed tomography (SPECT) myocardial perfusion imaging has proven to have prognostic importance in patients with suspected stable coronary artery disease (CAD). The recently introduced ultrafast cadmium zinc telluride (CZT)-based gamma cameras have been associated with less equivocal findings and more normal interpretations, allowing stress-only imaging to be performed more often. However, it is yet unclear whether normal stress-only CZT SPECT has comparable prognostic value as normally interpreted stress-only conventional SPECT. The study population consisted of 1,650 consecutive patients without known CAD with normal stress-only myocardial perfusion results with either conventional (n = 362) or CZT SPECT (n = 1,288). The incidence of major adverse cardiac events (MACE, all-cause death, non-fatal myocardial infarction and/or coronary revascularization) was compared between the conventional SPECT and CZT SPECT groups. Multivariable analyses using the Cox model were used to adjust for differences in baseline variables. Patients scanned with CZT were less often male (33 vs 39 %), had less often hypercholesterolaemia (41 vs 50 %) and had more often a family history of CAD (57 vs 49 %). At a median follow-up time of 37 months (interquartile range 28-45 months) MACE occurred in 68 patients. The incidence of MACE was 1.5 %/year in the CZT group, compared to 2.0 %/year in the conventional group (p = 0.08). After multivariate analyses, there was a trend to a lower incidence of MACE in the CZT SPECT group (hazard ratio 0.61, 95 % confidence interval 0.35-1.04, p = 0.07). The prognostic value of normal stress-only CZT SPECT is at least comparable and may be even better than that of normal conventional stress SPECT. (orig.)

  18. Usefulness of change ratio map in 99mTc-HMPAO SPECT with acetazolamide enhancement

    International Nuclear Information System (INIS)

    Yamamoto, Naoyuki

    1996-01-01

    Although a sequential 99m Tc-HMPAO SPECT technique with Diamox test (seq-SPECT) is a simple and time-saving procedure to assess brain perfusion reserve, the influence of the first dose of the tracer on the second one is not negligible. Therefore, a subtraction of the rest-SPECT from the 2nd SPECT is widely-used. However, subtracted SPECT images not only need to be corrected for the injected dose and the radiochemical purity due to inherent instability of HMPAO but also are usually degraded in quality. This study was undertaken to resolve these problems utilizing a change ratio (CR) map. The CR map was obtained by dividing 2nd SPECT by rest-SPECT. Prior to subtraction, the 2nd SPECT was normalized with the ratio of the mean whole brain counts between both SPECTs. To validate CR map, 7 patients were studied with both seq-SPECT and 133 Xe inhalation CBF measurement (Xe-CBF). The right to left count ratio obtained from the ROIs placed on MCA territory of CR map correlated well with that from Xe-CBF (r=0.89, p<0.01). Fifty-three patients with stroke underwent the seq-SPECT which was compared with the cerebral angiography (CAG) and classified into 4 groups according to the CR map. In 25 patients, all of the rest-, the subtracted-SPECT and the CR map did not show any difference between the affected side and the contralateral normal side. Seven patients with normal rest-SPECT showed decreased subtracted-SPECT counts and CR on the affected side. Three of them showed more than 75% stenosis on CAG. Four patients with the decreased counts both at the rest-and the subtracted-SPECT revealed no difference on the CR map suggesting the matched decrease of both blood flow and metabolism in the affected side. In conclusion, the CR map was a simple and useful method to evaluate the brain perfusion reserve with the seq-SPECT. (author)

  19. Brain perfusion SPECT in patients with mild cognitive impairment and Alzheimer's disease: comparison of a semiquantitative and a visual evaluation

    International Nuclear Information System (INIS)

    Staffen, W.; Schoenauer, U.; Spindler, I.; Mair, A.; Iglseder, B.; Ladurner, H.G.; Zauner, H.; Bernroider, G.

    2006-01-01

    Due to the increasing importance of early recognition and differential diagnosis of dementias, cerebral perfusion scans using 'single photon emission computed tomography' (SPECT) are increasingly integrated into the examination routine. The goal of this study was to check the diagnostic validity of SPECT scans of MCI- and DAT-patients, two subgroups out of 369 persons with etiologically unclear cognitive dysfunction, which underwent an assessment program for probable dementia including cognitive testing, cranial computed tomography, ultrasound, routine laboratory testing including vascular risk factors. After exclusion of patients with no or other forms of dementia we analyzed SPECT data of patients with mild cognitive impairment (MCI; n = 85) and dementia of the Alzheimer type (DAT; n = 78) in comparison with a healthy control group (n = 34). Visual assessment as well as a manual 'regions of interest' (ROI) regionalization of the cortex were performed, whereby a ROI/cerebellum ratio was calculated as a semi-quantitative value. Association cortex areas were assessed regarding frontal, temporal, and parietal lobes of both hemispheres. When comparing the ratios of patients with DAT and controls, we found a statistically significant reduction of the cerebral perfusion in all measured cortex areas (p < 0.001). The comparison of patients with MCI with the selected control group also established a statistically significant difference in the cerebral perfusion for the evaluated cortex areas with the exception of the left hemispheric frontal and parietal cortex. A considerable number of the MCI patients showed an MMSE-score within the normal range, but with regard to the perfusion in the right hemispheric association cortex these patients also could be distinguished unambiguously from controls. Sensitivity levels found by visual assessment were at least as high as those found by the ROI method (pathological assessment: visual 49.4 % vs. ROI 47.1 % for MCI; visual 75.6 % vs

  20. SPECT and MRI in the diagnosis of epilepsy

    International Nuclear Information System (INIS)

    Gruenwald, F.; Biersack, H.J.; Bockisch, A.; Elger, C.E.; Durwen, H.F.; Penin, H.

    1989-01-01

    This study presents the results obtained using SPECT and MRI in epilepsy - mainly based on presurgical investigation in therapy-resistant cases of temporal lobe epilepsy. MRI was positive in 61% of 102 examined patients, SPECT was positive in 84%. In 46 patients with temporal lobe epilepsy subjected to partial temporal lobectomy was performed later on there was agreement of the results obtained with regard to the lateralisation in 74%. Although MRI, due to its sensitivity is superior to CT in diagnosis of epilepsy, CT should be performed in any case because some morphological changes - especially small arteriovenous malformations - are only seen in CT. MRI and SPECT should be considered as two complementary methods in epilepsy diagnosis, serving to evaluate morphology and function. A definite statement as to the predictive value of both methods remains to be made depending on a comparison of the results with the postoperative outcome referring to seizure frequency and cognitive function. (orig.) [de

  1. Improvement of Cerebral Hypoperfusion with Levothyroxine Therapy in Hashimoto's Encephalopathy Demonstrated by 99mTc-HMPAO-SPECT

    Science.gov (United States)

    Schnedl, Wolfgang J.; Mirzaei, Siroos; Wallner-Liebmann, Sandra J.; Tafeit, Erwin; Mangge, Harald; Krause, Robert; Lipp, Rainer W.

    2013-01-01

    Background Hashimoto's encephalopathy (HE) is a rare immune-mediated encephalopathy associated with autoimmune Hashimoto's thyroiditis. Objectives and Methods We report on a patient with HE and significant clinical improvement correlating with an increase in cerebral blood flow demonstrated by hexamethylpropyleneamine oxime (HMPAO) single-photon emission computed tomography (SPECT). HMPAO-SPECT was performed with 740 MBq of technetium-99m-HMPAO. To demonstrate the improvement in regional cerebral blood flow, individual regions of interest were drawn around visually diminished HMPAO uptake, the lesion to reference region ratio was calculated and transverse section images and semi-quantitative measurements were performed. Results We show a 5-year follow-up with significant clinical improvement, a 10-fold reduction in autoantibodies to thyroid peroxidase and an approximately 20% improvement in cerebral blood flow with HMPAO-SPECT. Conclusion Adequate levothyroxine treatment achieving and maintaining euthyroidism should be considered as therapy to lower autoantibodies and improve clinical outcome in patients with Hashimoto's thyroiditis and encephalopathy. PMID:24783049

  2. Effect of solvent/detergent-treated pooled plasma on fibrinolysis in reconstituted whole blood.

    Science.gov (United States)

    Saadah, Nicholas H; van der Meer, Pieter F; Brinkman, Herm Jan M; de Korte, Dirk; Bontekoe, Ido J; Korsten, Herbert H; Middelburg, Rutger A; van der Bom, Johanna G; Schipperus, Martin R

    2017-10-01

    Hyperfibrinolysis has been observed in patients heavily transfused with solvent/detergent-treated pooled plasma (S/D plasma). We compared coagulation and fibrinolytic variables in blood containing S/D plasma with blood containing fresh-frozen plasma (FFP), with and without α2-antiplasmin or tranexamic acid (TXA) supplementation. Whole blood samples were reconstituted from red blood cells, platelet (PLT) concentrates, and varying mixtures of FFP and S/D plasma. Hematocrit and PLT count of reconstituted whole blood samples were varied. For a subset of runs, α2-antiplasmin or TXA was added to S/D plasma whole blood samples. Thromboelastography (TEG) analysis was performed to assess 50% clot lysis time (CLT 50% ), maximum amplitude (MA), and initial clotting time (R-time). The change in CLT 50% of whole blood as the plasma compartment transitions from FFP to S/D plasma was -52% (95% confidence interval [CI], -60% to -45%; p plasma in whole blood. α2-Antiplasmin and TXA restored clot lysis time in S/D plasma whole blood. Whole blood with S/D plasma has shorter clot lysis times in vitro compared to whole blood with FFP. α2-Antiplasmin and TXA restore clot lysis time of S/D plasma whole blood to that of FFP whole blood. Clinicians should be aware of the decreased clot lysis time associated with S/D plasma transfusion. © 2017 AABB.

  3. Diagnostic pathway of integrated SPECT/CT for coronary artery disease

    International Nuclear Information System (INIS)

    Slart, Riemer H.J.A.; Tio, Rene A.; Zijlstra, Felix; Dierckx, Rudi A.

    2009-01-01

    Treatment strategy in patients with suspected coronary artery disease (CAD) is driven by symptomatology in combination with diagnostic evaluation of the extent and/or severity of atherosclerosis in the coronary arteries and ischemia in the myocardium, i.e., the anatomic and functional correlates of CAD. Whereas multislice row computed tomography (MSCT) has the advantage of detecting coronary atherosclerosis at its earliest stages, thereby allowing initiation of appropriate therapeutic measures well before development of obstructive CAD, myocardial perfusion imaging (MPI) SPECT can clarify the hemodynamic consequences of the anatomic findings on MSCT based on a functional assessment of myocardial blood flow. There is a lack of correlation between coronary artery calcium (CAC), coronary artery stenosis, and MPI SPECT. Therefore CAC scoring and stress MPI should be thus considered complementary approaches rather than exclusionary in the evaluation of the patient at risk for CAD. The integration of anatomic and functional information may provide additional information for the clinician by the improved risk stratification and diagnostic accuracy of integrated techniques. The majority of previous studies are based on a sequential flowchart, starting with either SPECT or CAC scoring that finally directs the therapeutic strategy. Patients at low risk for CAD can be selected for primary prevention, and patients at high risk for CAD can be directly selected for coronary angiography (CAG). The remaining group of patients at intermediate risk for CAD can be substratified into lower- and higher-risk categories based on the presence or absence of stress-induced ischemia on MPI SPECT and CAC scoring. An integration of SPECT and CAC as a starting point for CAD detection in symptomatic patients at intermediate risk for CAD may facilitate a tailored diagnostic as well as therapeutic approach. Finally, using SPECT/CT, MPI SPECT, and CAC findings may be completed with CT angiography

  4. Single-photon emission tomography (SPECT) with 123I-amphetamine in cerebral ischemia

    International Nuclear Information System (INIS)

    Koenig, B.; Donis, J.; Mostbeck, A.; Koehn, H.

    1987-01-01

    The uptake of 123 I-amphetamine (IMP) in brain mainly corresponds to regional perfusion. Distribution of IMP can be visualized in tomographic slices by single-photon emission computed tomography (SPECT). For better evaluation and comparison in follow-up studies, right/left ratios were computed and an asymmetry index calculated. The most sensitive asymmetry index was achieved by 120 average circumferential profiles. In 52 patients with stroke and 16 controls the respective sensitivities of IMP-SPECT, computed tomography (CT), static and dynamic brain scanning and angiography were evaluated. In patients with TIA and PRIND the IMP-SPECT had the highest sensitivity of all non-invasive methods. In patients with completed stroke, the sensitivity of IMP-SPECT was comparable with that of CT (90 vs. 93%). There was a significant correlation between the IMP asymmetry index and the clinical and social score (p [de

  5. Clinical utility of spatially normalized PET and SPECT to evaluate patients with memory and cognitive impairments

    International Nuclear Information System (INIS)

    Okumura, Ayumi; Nakayama, Noriyuki; Soeda, Akio; Miwa, Kazuhiro; Shinoda, Jun; Iwama, Toru

    2004-01-01

    We assessed cerebral metabolism and blood flow in patients with memory and other cognitive impairment using the easy Z score imaging system (eZIS) and statistical parametric mapping (SPM) of FDG-PET and SPECT scans. Twenty patients with dementia (12 Alzheimer's disease (AD), 3 diffuse Lewy body disease (DLB), and 2 frontotemporal dementia (FTD)) and twenty with diffuse axonal injury (DAI) and cognitive impairments were studied with FDG-PET and ECD-SPECT. All images were analyzed using eZIS with the same processing procedures, including smoothing, normalization, and z-transformation, and compared to a database of normals. Z score maps were super-imposed on 3D MRI brain images. Group analyses were performed using SPM. Age-related declines in cerebral metabolism and blood flow were observed in the anterior cingulate association area. In contrast, reductions in these cerebral functions correlated best with severity of AD in the posterior cingulate association areas. In DLB and FTD, eZIS analysis of PET and SPECT revealed reductions of cerebral functions in specific areas. DAI showed low metabolism and blood flow in mesiofrontal cortex including the anterior cingulate association area. Dysfunction of the anterior cingulate association area in DAI, which resembled age-related cognitive decline, may be responsible for cognitive impairments. Overall, PET and SPECT scans showed significant correlations according to the type of dementia. Spatially normalized maps contributed to PET and SPECT image interpretation for patients with memory and cognitive impairments because better 3D visualization allowed more objective and systematic investigations. (author)

  6. Comprehensive MRA of the lower limbs including high-resolution extended-phase infra-inguinal imaging with gadobenate dimeglumine: Initial experience with inter-individual comparison to the blood-pool contrast agent gadofosveset trisodium

    International Nuclear Information System (INIS)

    Christie, A.; Chandramohan, S.; Roditi, G.

    2013-01-01

    Aim: To compare extended-phase imaging using an extracellular space contrast agent, gadobenate dimeglumine, to imaging with a blood-pool contrast agent, gadofosveset, for magnetic resonance angiography. Materials and methods: A lower-limb magnetic resonance angiography (MRA) protocol (dynamic crural, three-station bolus chase, and infra-inguinal high resolution) designed for blood-pool agent imaging was adapted for use with the extracellular agent, gadobenate dimeglumine, primarily by using a triphasic injection protocol. Ten patients scanned with gadofosveset were compared to 10 patients scanned with gadobenate. The dynamic, bolus chase, and high-resolution images were scored for quality on a Likert scale (from 1–5). Signal- and contrast-to-noise ratios were analysed, and Mann–Whitney U statistical analysis performed. Results: There was no significant difference for the dynamic imaging or the aorto-iliac station of the bolus chase. Infra-inguinal bolus chase images were higher quality (p < 0.05 Mann–Whitney U test) with gadobenate. Signal analysis confirmed lower signal and contrast for venous imaging on the high spatial resolution acquisitions with gadobenate; however, this allowed improved arterial conspicuity. Conclusion: Extended-phase imaging using an extracellular space contrast agent is feasible and provides image quality to equal imaging with a blood-pool contrast agent.

  7. Perfusion differences on SPECT and PWI in patients with acute ischemic stroke

    International Nuclear Information System (INIS)

    Nuutinen, Juho; Liu, Yawu; Laakso, Mikko P.; Karonen, Jari O.; Vanninen, Esko J.; Kuikka, Jyrki T.; Aronen, Hannu J.; Vanninen, Ritva L.

    2009-01-01

    The purposes of the present study were to compare the flow defect volumes on perfusion-weighted magnetic resonance imaging (PWI) and 99m Tc-labeled ethylcysteinate dimer ( 99m Tc-ECD) single photon emission computed tomography (SPECT) at acute and subacute stages of ischemic stroke and to analyze the relationship between the detected flow defects on the two methods and neurological status and clinical outcomes. Perfusion defects on PWI and SPECT were measured within 48 h and on day 8 of the onset of stroke from 22 patients with their first-ever acute supratentorial ischemic stroke. The primary neurological status was evaluated prior to the imaging. Clinical outcome was assessed at 3 months after the onset of the stroke. The volumes of cerebral blood flow (CBF) defects did not differ between SPECT and PWI within the 48-h examinations. However, the volume of CBF defect was significantly larger on SPECT than on PWI on day 8 (p = 0.03). Within the 48-h examinations, the CBF defect volumes on SPECT and PWI were comparably related to the neurological status. On day 8, the CBF defect volume on SPECT showed higher correlation to the neurological status and more precisely predicted the clinical outcomes at 3 months than PWI. 99m TC-ECD-SPECT and PWI both have ability to detect cerebral hypoperfusion in patients with ischemic stroke but with some differences. The value of SPECT is more accurate in terms of the delayed outcome, such as prognosis and rehabilitation planning. (orig.)

  8. Perfusion differences on SPECT and PWI in patients with acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Nuutinen, Juho [Kuopio University Hospital, University of Kuopio, Department of Neurology, Kuopio (Finland); Liu, Yawu; Laakso, Mikko P. [Kuopio University Hospital, University of Kuopio, Department of Neurology, Kuopio (Finland); Kuopio University Hospital, University of Kuopio, Department of Clinical Radiology, P. O. Box 1777, Kuopio (Finland); Karonen, Jari O. [Mikkeli Central Hospital, Department of Radiology, Mikkeli (Finland); Vanninen, Esko J. [Kuopio University Hospital, University of Kuopio, Department of Clinical Physiology and Nuclear Medicine, Kuopio (Finland); Kuikka, Jyrki T. [Kuopio University Hospital, University of Kuopio, Department of Clinical Physiology and Nuclear Medicine, Kuopio (Finland); Niuvanniemi Hospital, Kuopio (Finland); Aronen, Hannu J. [University of Turku, Department of Radiology, Turku (Finland); Vanninen, Ritva L. [Kuopio University Hospital, University of Kuopio, Department of Clinical Radiology, P. O. Box 1777, Kuopio (Finland)

    2009-10-15

    The purposes of the present study were to compare the flow defect volumes on perfusion-weighted magnetic resonance imaging (PWI) and {sup 99m}Tc-labeled ethylcysteinate dimer ({sup 99m}Tc-ECD) single photon emission computed tomography (SPECT) at acute and subacute stages of ischemic stroke and to analyze the relationship between the detected flow defects on the two methods and neurological status and clinical outcomes. Perfusion defects on PWI and SPECT were measured within 48 h and on day 8 of the onset of stroke from 22 patients with their first-ever acute supratentorial ischemic stroke. The primary neurological status was evaluated prior to the imaging. Clinical outcome was assessed at 3 months after the onset of the stroke. The volumes of cerebral blood flow (CBF) defects did not differ between SPECT and PWI within the 48-h examinations. However, the volume of CBF defect was significantly larger on SPECT than on PWI on day 8 (p = 0.03). Within the 48-h examinations, the CBF defect volumes on SPECT and PWI were comparably related to the neurological status. On day 8, the CBF defect volume on SPECT showed higher correlation to the neurological status and more precisely predicted the clinical outcomes at 3 months than PWI. {sup 99m}TC-ECD-SPECT and PWI both have ability to detect cerebral hypoperfusion in patients with ischemic stroke but with some differences. The value of SPECT is more accurate in terms of the delayed outcome, such as prognosis and rehabilitation planning. (orig.)

  9. Quantification of wall motion and phase of contraction in tomographic gated blood pool studies using length-based Fourier analysis

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Kenichi; Bunko, Hisashi; Taki, Junichi; Nambu, Ichiro; Shiire, Yasushi; Tonami, Norihisa; Hisada, Kinichi; Tada, Akira; Kojima, Kazuhkio

    1985-03-01

    Length-based Fourier analysis, a new method for quantification of wall motion and timing of contraction, was applied to tomographic gated blood pool study. Two parameters, percent-length shortening (%LS) and length-based phase were calculated based on the time-length curves from a center to ventricular edges, and compared with the count-based method. In mathematical models for tomographic gated blood pool images, the severity of asynergy was easily determined by length-based method, and the accuracy of the parameters was good. As to the setting of the center, fixed center provided more reliable parameters than the method using movable center, i.e., when a center of gravity was determined in each frame. By length-based Fourier analysis, quantification of wall motion was easily performed, and the initial inward movement caused by the accessory conduction pathway was assessed in patients with Wolff-Parkinson-White syndrome. Length-based approach was considered to be reasonable and effective because the movements of the ventricular edges are essential in tomographic gated blood pool images.

  10. Quantification of wall motion and phase of contraction in tomographic gated blood pool studies using length-based Fourier analysis

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Bunko, Hisashi; Taki, Junichi; Nambu, Ichiro; Shiire, Yasushi; Tonami, Norihisa; Hisada, Kinichi; Tada, Akira; Kojima, Kazuhiko.

    1985-01-01

    Length-based Fourier analysis, a new method for quantification of wall motion and timing of contraction, was applied to tomographic gated blood pool study. Two parameters, percent-length shortening (%LS) and length-based phase were calculated based on the time-length curves from a center to ventricular edges, and compared with the count-based method. In mathematical models for tomographic gated blood pool images, the severity of asynergy was easily determined by length-based method, and the accuracy of the parameters was good. As to the setting of the center, fixed center provided more reliable parameters than the method using movable center, i.e., when a center of gravity was determined in each frame. By length-based Fourier analysis, quantification of wall motion was easily performed, and the initial inward movement caused by the accessory conduction pathway was assessed in patients with Wolff-Parkinson-White syndrome. Length-based approach was considered to be reasonable and effective because the movements of the ventricular edges are essential in tomographic gated blood pool images. (author)

  11. Studies on asymptomatic cerebral ischemia in coronary heart disease with special reference to evaluation of postural changes in cerebral blood flow with {sup 99m}Tc-ECD brain SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Sinozaki, Hideko [Teikyo Univ., Tokyo (Japan). Faculty of Medicine

    2001-03-01

    Postural changes in cerebral blood flow in patients with coronary heart disease (CHD) were evaluated with SPECT to detect asymptomaic cerebral ischemia (ACI). {sup 99m}Tc-ECD was used as a tracer. We developed a new analysis system for the processing of multiple images, making it possible to avoid the spatial shift in ROIs in different positions. The severity of ACI was classified into 3 groups based on SPECT findings in the supine position: group 1 without any abnormalities in cerebral perfusion, group 2 with a single perfusion defect, and group 3 with a number of perfusion defects. No cerebral siteobserved in any group showed a significant difference between the supine and upright positions in cerebral perfusion. Each group in each position, however, revealed a consistent perfusion pattern characterized by a significant decrease in perfusion in the occipital, temporal and frontal lobes. Moreover, the decrease in the latter two sites was significantly greater than in the former site. Concerning clinical profiles, hypertension and the thickness of the intima and media complex (TIMC) of the common carotid artery significantly correlated with the severity of ACI. Furthermore, in multiple regression analysis, only TIMC was identified as a significant determinant of ACI. In conclusion, cerebral blood flow determined with {sup 99m}Tc-ECD SPECT could accurately detect ACI in patients with CHD. (author)

  12. Three-dimensional magnetic resonance coronary angiography using a new blood pool contrast agent : Initial experience

    NARCIS (Netherlands)

    Bedaux, WLF; Hofman, MBM; Wielopolski, PA; de Cock, CC; Hoffmann, [No Value; Oudkerk, M; de Feyter, PJ; van Rossum, AC

    2002-01-01

    Objective: The aim of this feasibility study was to assess the effect of a new blood pool contrast agent on magnetic resonance coronary angiography (MRCA) in patients suspected of having coronary artery disease. Methods: Nine patients referred for diagnostic x-ray coronary, angiography in the

  13. SPM analysis of cerebrovascular reserve capacity after stimulation with acetazolamide measured by Tc-99m ECD SPECT in normal brain MRI patient

    Energy Technology Data Exchange (ETDEWEB)

    Lee, M. H.; Yoon, S. N.; Yoon, J. K.; Cho, C. W. [College of Medicine, Univ. of Ajou, Suwon (Korea, Republic of)

    2003-07-01

    This study was undertaken to evaluate normal response of acetazolamide in normal individuals, whose brain MRI is normal, using SPM99. In total, 10 Tc- 99m ECD brain SPECT were evaluated retrospectively. The half of the patients were male. Their mean age was 47.1 years old with a range of 33-61 years. They all visited our neurology department to evaluate stroke symptom. Their brain MRI was normal. Rest/acetazolamide brain SPECT was perfomed using Tc-99m ECD and the sequential injection and subtraction method. SPECT was acquired using fanbeam collimators and triple-head gamma camera (MultiSPECT III, Siemens medical systems, Inc. Hoffman Estates, III, USA). Chang's attenuation correction was applied their brain SPECT revealed normal rCBF pattern in visual analysis by two nuclear physician and they were diagnosed clinically normal. Using SPM method, we compared rest brain SPECT images with those of acetazolamide brain SPECT and measured the extent of the area with significant perfusion change (P<0.05) in predefined 34 cerebral regions. Acetazolamide brain SPECT showed no significant decreased region in comparison to rest brain SPECT. Only small portion of left mid temporal gyrus revealed increased rCBF on acetazolamide brain SPECT in comparison to rest brain SPECT. It apperas that there is no significant change in rCBF between rest and acetazolamide brain SPECT using Tc-99m ECD. The small number of this study is limitation of our study.

  14. Detection of a possible epilepsy focus in a preoperated patient by perfusion SPECT and computer-aided subtraction analysis

    International Nuclear Information System (INIS)

    Apostolova, I.; Wilke, F.; Clausen, M.; Buchert, R.; Lindenau, M.; Stodieck, S.; Fiehler, J.; Heese, O.

    2008-01-01

    Ictal perfusion SPECT with either 9 9mTc-hexamethylpropylene amine oxime (HMPAO) or 9 9mTc-ethylcysteinate dimer (ECD) has been reported to provide very good sensitivity for the determination of the SOA in fTLE. Sensitivity of interictal perfusion SPECT is much lower. However, interictal perfusion SPECT might enhance the specificity of ictal SPECT findings by improving the discrimination between seizure related local hyperperfusion and intersubject variability of perfusion (physiologic hyperperfusion). In addition, the combination of interictal and ictal perfusion SPECT might provide improved sensitivity compared to ictal SPECT alone, particularly when computer-aided subtraction of ictal and interictal SPECT is used instead of traditional side-by-side visual comparison. The combination of ictal and interictal perfusion SPECT eliminates not only physiological inter-subject variance, but it can also eliminate severe partial volume effects. Computer-aided subtraction analysis appears particularly useful in this case

  15. Detection of a possible epilepsy focus in a preoperated patient by perfusion SPECT and computer-aided subtraction analysis

    Energy Technology Data Exchange (ETDEWEB)

    Apostolova, I.; Wilke, F.; Clausen, M.; Buchert, R. [Univ. Medical Center Hamburg-Eppendorf (Germany). Dept. of Nuclear Medicine; Lindenau, M.; Stodieck, S. [Protestant Hospital Alsterdorf, Hamburg (Germany). Dept. of Neurology and Epileptology; Fiehler, J. [Univ. Medical Center Hamburg-Eppendorf (Germany). Dept. of Neuroradiology; Heese, O. [Univ. Medical Center Hamburg-Eppendorf (Germany). Neurological Surgery

    2008-07-01

    Ictal perfusion SPECT with either {sup 9}9mTc-hexamethylpropylene amine oxime (HMPAO) or {sup 9}9mTc-ethylcysteinate dimer (ECD) has been reported to provide very good sensitivity for the determination of the SOA in fTLE. Sensitivity of interictal perfusion SPECT is much lower. However, interictal perfusion SPECT might enhance the specificity of ictal SPECT findings by improving the discrimination between seizure related local hyperperfusion and intersubject variability of perfusion (physiologic hyperperfusion). In addition, the combination of interictal and ictal perfusion SPECT might provide improved sensitivity compared to ictal SPECT alone, particularly when computer-aided subtraction of ictal and interictal SPECT is used instead of traditional side-by-side visual comparison. The combination of ictal and interictal perfusion SPECT eliminates not only physiological inter-subject variance, but it can also eliminate severe partial volume effects. Computer-aided subtraction analysis appears particularly useful in this case.

  16. Comparison of planar images and SPECT with bayesean preprocessing for the demonstration of facial anatomy and craniomandibular disorders

    International Nuclear Information System (INIS)

    Kircos, L.T.; Ortendahl, D.A.; Hattner, R.S.; Faulkner, D.; Taylor, R.L.

    1984-01-01

    Craniomandiublar disorders involving the facial anatomy may be difficult to demonstrate in planar images. Although bone scanning is generally more sensitive than radiography, facial bone anatomy is complex and focal areas of increased or decreased radiotracer may become obscured by overlapping structures in planar images. Thus SPECT appears ideally suited to examination of the facial skeleton. A series of patients with craniomandibular disorders of unknown origin were imaged using 20 mCi Tc-99m MDP. Planar and SPECT (Siemens 7500 ZLC Orbiter) images were obtained four hours after injection. The SPECT images were reconstructed with a filtered back-projection algorithm. In order to improve image contrast and resolution in SPECT images, the rotation views were pre-processed with a Bayesean deblurring algorithm which has previously been show to offer improved contrast and resolution in planar images. SPECT images using the pre-processed rotation views were obtained and compared to the SPECT images without pre-processing and the planar images. TMJ arthropathy involving either the glenoid fossa or the mandibular condyle, orthopedic changes involving the mandible or maxilla, localized dental pathosis, as well as changes in structures peripheral to the facial skeleton were identified. Bayesean pre-processed SPECT depicted the facial skeleton more clearly as well as providing a more obvious demonstration of the bony changes associated with craniomandibular disorders than either planar images or SPECT without pre-processing

  17. The validation and the limits of SPECT for patients suffering from cerebrovascular accidents

    International Nuclear Information System (INIS)

    Mizukawa, Norihiko; Yano, Ichiro; Tenjin, Hiroshi

    1989-01-01

    Contemporaneous single photon emission computed tomography (SPECT) and positron emission tomography (PET) were performed in 10 patients with cerebrovascular accidents (CVA), whose ages ranged from 11 to 67 years. I-123-isopropyl-iodoamphetamine (IMP) and/or Tc-99m hexamethylpropyleneamine oxime (HM-PAO) were used for SPECT. Cerebral blood flow (CBF), oxygen extraction fraction (OEF), and cerebral metabolic rate for oxygen (CMRO 2 ) were measured by an O-15 labelled gas continuous-inhalation method. SPECT images were quite similar to CBF and CMRO 2 during the chronic stage of CVA. Two patietns with vasospasm during the subacute stage had apparently low CBF and CMRO 2 on PET, but did not have low perfusion on SPECT. Luxury perfusion areas were detected in 4 subacute stage patients and one chronic stage patient. A redistribution of IMP was detected in two patients with infarction during subacute stage. CMRO 2 value in such an area was 2.0 ml/100 g/min. Low CBF and/or CMRO 2 areas were well visualized by IMP rather than by HM-PAO SPECT. (N.K.)

  18. Preclinical imaging characteristics and quantification of Platinum-195m SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Aalbersberg, E.A.; Wit-van der Veen, B.J. de; Vegt, E.; Vogel, Wouter V. [The Netherlands Cancer Institute (NKI-AVL), Department of Nuclear Medicine, Amsterdam (Netherlands); Zwaagstra, O.; Codee-van der Schilden, K. [Nuclear Research and Consultancy Group (NRG), Petten (Netherlands)

    2017-08-15

    In vivo biodistribution imaging of platinum-based compounds may allow better patient selection for treatment with chemo(radio)therapy. Radiolabeling with Platinum-195m ({sup 195m}Pt) allows SPECT imaging, without altering the chemical structure or biological activity of the compound. We have assessed the feasibility of {sup 195m}Pt SPECT imaging in mice, with the aim to determine the image quality and accuracy of quantification for current preclinical imaging equipment. Enriched (>96%) {sup 194}Pt was irradiated in the High Flux Reactor (HFR) in Petten, The Netherlands (NRG). A 0.05 M HCl {sup 195m}Pt-solution with a specific activity of 33 MBq/mg was obtained. Image quality was assessed for the NanoSPECT/CT (Bioscan Inc., Washington DC, USA) and U-SPECT{sup +}/CT (MILabs BV, Utrecht, the Netherlands) scanners. A radioactivity-filled rod phantom (rod diameter 0.85-1.7 mm) filled with 1 MBq {sup 195m}Pt was scanned with different acquisition durations (10-120 min). Four healthy mice were injected intravenously with 3-4 MBq {sup 195m}Pt. Mouse images were acquired with the NanoSPECT for 120 min at 0, 2, 4, or 24 h after injection. Organs were delineated to quantify {sup 195m}Pt concentrations. Immediately after scanning, the mice were sacrificed, and the platinum concentration was determined in organs using a gamma counter and graphite furnace - atomic absorption spectroscopy (GF-AAS) as reference standards. A 30-min acquisition of the phantom provided visually adequate image quality for both scanners. The smallest visible rods were 0.95 mm in diameter on the NanoSPECT and 0.85 mm in diameter on the U-SPECT{sup +}. The image quality in mice was visually adequate. Uptake was seen in the kidneys with excretion to the bladder, and in the liver, blood, and intestine. No uptake was seen in the brain. The Spearman correlation between SPECT and gamma counter was 0.92, between SPECT and GF-AAS it was 0.84, and between GF-AAS and gamma counter it was0.97 (all p < 0

  19. Voxel-by-voxel analysis of brain SPECT perfusion in Fibromyalgia

    International Nuclear Information System (INIS)

    Guedj, Eric; Taieb, David; Cammilleri, Serge; Lussato, David; Laforte, Catherine de; Niboyet, Jean; Mundler, Olivier

    2007-01-01

    We evaluated brain perfusion SPECT at rest, without noxious stiumuli, in a homogeneous group of hyperalgesic FM patients. We performed a voxel-based analysis in comparison to a control group, matched for age and gender. Under such conditions, we made the assumption that significant cerebral perfusion abnormalities could be demonstrated, evidencing altered cerebral processing associated with spontaneous pain in FM patients. The secondary objective was to study the reversibility and the prognostic value of such possible perfusion abnormalities under specific treatment. Eighteen hyperalgesic FM women (mean age 48 yr; range 25-63 yr; ACR criteria) and 10 healthy women matched for age were enrolled in the study. A voxel-by-voxel group analysis was performed using SPM2 (p<0.05, corrected for multiple comparisons). All brain SPECT were performed before any change was made in therapy in the pain care unit. A second SPECT was performed a month later after specific treatment by Ketamine. Compared to control subjects, we observed individual brain SPECT abnormalities in FM patients, confirmed by SPM2 analysis with hyperperfusion of the somatosensory cortex and hypoperfusion of the frontal, cingulate, medial temporal and cerebellar cortices. We also found that a medial frontal and anterior cingulate hypoperfusions were highly predictive (PPV=83%; NPV=91%) of non-response on Ketamine, and that only responders showed significant modification of brain perfusion, after treatment. In the present study performed without noxious stimuli in hyperalgesic FM patients, we found significant hyperperfusion in regions of the brain known to be involved in sensory dimension of pain processing and significant hypoperfusion in areas assumed to be associated with the affective dimension. As current pharmacological and non-pharmacological therapies act differently on both components of pain, we hypothesize that SPECT could be a valuable and readily available tool to guide individual therapeutic

  20. Voxel-by-voxel analysis of brain SPECT perfusion in Fibromyalgia

    Energy Technology Data Exchange (ETDEWEB)

    Guedj, Eric [Service Central de Biophysique et de Medecine Nucleaire, AP-HM Timone, Marseille (France)]. E-mail: eric.guedj@ap-hm.fr; Taieb, David [Service Central de Biophysique et de Medecine Nucleaire, AP-HM Timone, Marseille (France); Cammilleri, Serge [Service Central de Biophysique et de Medecine Nucleaire, AP-HM Timone, Marseille (France); Lussato, David [Service Central de Biophysique et de Medecine Nucleaire, AP-HM Timone, Marseille (France); Laforte, Catherine de [Service Central de Biophysique et de Medecine Nucleaire, AP-HM Timone, Marseille (France); Niboyet, Jean [Unite d' Etude et de Traitement de la Douleur, Clinique La Phoceanne, Marseille (France); Mundler, Olivier [Service Central de Biophysique et de Medecine Nucleaire, AP-HM Timone, Marseille (France)

    2007-02-01

    We evaluated brain perfusion SPECT at rest, without noxious stiumuli, in a homogeneous group of hyperalgesic FM patients. We performed a voxel-based analysis in comparison to a control group, matched for age and gender. Under such conditions, we made the assumption that significant cerebral perfusion abnormalities could be demonstrated, evidencing altered cerebral processing associated with spontaneous pain in FM patients. The secondary objective was to study the reversibility and the prognostic value of such possible perfusion abnormalities under specific treatment. Eighteen hyperalgesic FM women (mean age 48 yr; range 25-63 yr; ACR criteria) and 10 healthy women matched for age were enrolled in the study. A voxel-by-voxel group analysis was performed using SPM2 (p<0.05, corrected for multiple comparisons). All brain SPECT were performed before any change was made in therapy in the pain care unit. A second SPECT was performed a month later after specific treatment by Ketamine. Compared to control subjects, we observed individual brain SPECT abnormalities in FM patients, confirmed by SPM2 analysis with hyperperfusion of the somatosensory cortex and hypoperfusion of the frontal, cingulate, medial temporal and cerebellar cortices. We also found that a medial frontal and anterior cingulate hypoperfusions were highly predictive (PPV=83%; NPV=91%) of non-response on Ketamine, and that only responders showed significant modification of brain perfusion, after treatment. In the present study performed without noxious stimuli in hyperalgesic FM patients, we found significant hyperperfusion in regions of the brain known to be involved in sensory dimension of pain processing and significant hypoperfusion in areas assumed to be associated with the affective dimension. As current pharmacological and non-pharmacological therapies act differently on both components of pain, we hypothesize that SPECT could be a valuable and readily available tool to guide individual therapeutic

  1. Changes of rCBF 99mTc-HMPAO SPECT in a selected disorders

    International Nuclear Information System (INIS)

    Junik, R.

    2003-01-01

    With single photon emission computer tomography (SPECT) and HMPAO a noninvasive examination of regional cerebral blood flow can be performed (rCBF). The purpose of the SPECT examinations was to define the location and magnitude of blood flow disorder in selected diseases and the assessment of the results as complementary to morphological tests CT and MRI or functional tests, such as EEG. The examinations were carried out in 455 patients: 91 - patients with depression, 29 - congenital hypothyroidism, 66 - migraine, 34 - epilepsy, 6 - Landau-Kleffner syndrome, 20 - Alzheimer disease, 55 - with suspected Alzheimer disease, 105 - cerebral stroke, and 48 - transient cerebral ischemia. The control group comprised of 26 subjects. The SPECT method was used to perform examinations. The images were evaluated based on semiquantitative method. The asymmetry of activity and activity referred to the referential region were measured using symmetrical ROIs localized in hypoperfusion foci. The differences in perfusion in symmetric locations exceeding 10% were considered abnormal. During the depression stage, in patients with depression, a decrease of rCBF occurred. Regression of depression results in an increase of rCBF almost in the entire cerebrum. In patients with depression, SPECT examination is a useful method to monitor course of a disease and to objectively verify the results of treatment. 2. Disorders of rCBF, a decrease and/or asymmetry, occurred in patients with congenital hypothyroidism, migraine, and epilepsy. 3. There is a relation between patterns of cerebral perfusion in stroke, visible in SPECT image, and an extent and intensity of cerebral ischemia. (author)

  2. SPECT myocardial perfusion versus fractional flow reserve for evaluation of functional ischemia: A meta analysis

    International Nuclear Information System (INIS)

    Zhou, Tao; Yang, Lin-feng; Zhai, Ji-liang; Li, Jiang; Wang, Qi-meng; Zhang, Rui-jie; Wang, Sen; Peng, Zhao-hui; Li, Min; Sun, Gang

    2014-01-01

    Purpose: The present meta-analysis illustrates the accuracy of myocardial perfusion SPECT (MPS) to diagnose functional stenotic coronary artery disease (CAD) with fractional flow reserve (FFR) as standard reference. Methods: All investigators screened and selected studies that compared MPS with FFR in symptomatic patients with suspected CAD. Patients and study characteristics were independently extracted by two investigators; differences were resolved by consensus. Results: 13 articles, including 1,017 patients, 699 vessels were included in the study. No significant publication bias was detected (P = 0.65). At the patient level, the summary sensitivity and specificity were 77% (95% confidence interval [CI], 70–83%) and 77% (95%CI, 67–84%) for MPS. Vessel-level pooled sensitivity was 66% (95%CI, 57–74%) and specificity was 81% (95%CI, 70–89%). The overall diagnostic performance of MPS was moderate. [The area under the summary receiver operating characteristic (sROC) curve was 0.83]. No study influenced the pooled results larger than 0.03. Conclusions: The accuracy between FFR and MPS SPECT was moderate

  3. SPECT myocardial perfusion versus fractional flow reserve for evaluation of functional ischemia: A meta analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Tao; Yang, Lin-feng [Department of Medical Imaging, Jinan Military General Hospital, No, 25, Shifan Road, Jinan, Shandong Province, China. 250031 (China); Zhai, Ji-liang [Department of Medical Imaging, The Branch of TaiAn Central Hospital, Middle of Changcheng Road, Shandong Province, China. 271000 (China); Li, Jiang [Department of Medical Imaging, Affiliated Hospital of Taishan Medical University, No, 706, Taishan Road, Shandong Province, China. 271000 (China); Wang, Qi-meng [Department of Medical Imaging, Taishan Hospital of Traditional Chinese Medicine, No, 216, Yingxuan Street, Shandong Province, China. 271000. (China); Zhang, Rui-jie; Wang, Sen; Peng, Zhao-hui [Department of Medical Imaging, Jinan Military General Hospital, No, 25, Shifan Road, Jinan, Shandong Province, China. 250031 (China); Li, Min, E-mail: liminyingxiang@163.com [Department of Medical Imaging, Jinan Military General Hospital, No, 25, Shifan Road, Jinan, Shandong Province, China. 250031 (China); Sun, Gang, E-mail: cjr.sungang@vip.163.com [Department of Medical Imaging, Jinan Military General Hospital, No, 25, Shifan Road, Jinan, Shandong Province, China. 250031 (China)

    2014-06-15

    Purpose: The present meta-analysis illustrates the accuracy of myocardial perfusion SPECT (MPS) to diagnose functional stenotic coronary artery disease (CAD) with fractional flow reserve (FFR) as standard reference. Methods: All investigators screened and selected studies that compared MPS with FFR in symptomatic patients with suspected CAD. Patients and study characteristics were independently extracted by two investigators; differences were resolved by consensus. Results: 13 articles, including 1,017 patients, 699 vessels were included in the study. No significant publication bias was detected (P = 0.65). At the patient level, the summary sensitivity and specificity were 77% (95% confidence interval [CI], 70–83%) and 77% (95%CI, 67–84%) for MPS. Vessel-level pooled sensitivity was 66% (95%CI, 57–74%) and specificity was 81% (95%CI, 70–89%). The overall diagnostic performance of MPS was moderate. [The area under the summary receiver operating characteristic (sROC) curve was 0.83]. No study influenced the pooled results larger than 0.03. Conclusions: The accuracy between FFR and MPS SPECT was moderate.

  4. Scintigraphic detection of gynaecological tumours by sup(99m)Tc-HSA blood pool imaging

    Energy Technology Data Exchange (ETDEWEB)

    Georgiou, E C; Arkas, A Z; Alevizaki, C C; Gnafakis, N [Evangelismos Hospital, Athens (Greece). Dept. of Endocrinology and Radioisotopes; Evangelismos Hospital, Athens (Greece). Gynaecology Clinic)

    1979-12-01

    Three cases of scintigraphic visualization of gynaecological tumours by sup(99m)Tc-HSA blood pool imaging are presented, i.e. one case of fibrothecoma ('cold' area visualization) and two cases of fibromyoma ('hot' area visualization). It is suggested that this technique may be useful in the preoperative evaluation of gynaecological tumours and their vascularity.

  5. Gated blood pool scintigraphy in patients with valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Breuel, H.P.; Heusinger, J.H.; Hanisch, K.

    1984-10-01

    In 58 patients suffering from either stenosis or insufficiency of a single heart valve, gated blood pool scintigraphy was performed to determine the ejection fraction as well as the peak filling and peak ejection rates. It could be demonstrated that in patients with valvular disorders the ejection fraction was only moderately decreased, generally remaining in the lower reference range. The peak filling and ejection rates showed no pathologic changes with the exception of patients with aortic regurgitation where these rates were significantly decreased. Thus, the estimation of left ventricular peak filling and ejection rates may permit diagnosis of myocardial impairment in patients with valvular disease even under resting conditions.

  6. Regional cerebral blood flow of the patients with schizophrenia. A study using 99mTc-ECD SPECT at rest and activation

    International Nuclear Information System (INIS)

    Hu Ping; Wu Kening; Zeng Shiquan; Lin Zengtao; Yu Jinlong

    1996-01-01

    Regional cerebral blood flow (rCBF) changes of the patients with schizophrenia were observed. 99m Tc-ECD SPECT was performed on 22 patients with schizophrenia and 10 healthy volunteers at rest and activation with a cognitive task: a modified Wisconsin Card Sorting Test. At rest state, only 4 patients have abnormal rCBF pattern: left hemisphere over-perfusion relative to the right. A significant relative activation deficit in the left inferior prefrontal region was revealed in the patients during activation. The patients with schizophrenia may have frontal lobe dysfunction

  7. Technetium SPECT agents for imaging heart and brain

    International Nuclear Information System (INIS)

    Linder, K.E.

    1990-01-01

    One major goal of radiopharmaceutical research has been the development of technetium-based perfusion tracers for SPECT imaging of the heart and brain. The recent clinical introduction of the technetium complexes HM-PAO, ECD and DMG-2MP for brain imaging, and of CDO-MEB and MIBI for heart imaging promises to revolutionize the field of nuclear medicine. All of these agents appear to localize in the target tissue in proportion to blood flow, but their mechanisms of localization and/or retention may differ quite widely. In this talk, a survey of the new technetium SPECT agents will be presented. The inorganic and biological chemistry of these complexes, mechanisms of uptake and retention, QSAR studies, and potential clinical applications are discussed

  8. The Effect and Side Effect of Dipyridamole in Myocardial SPECT

    International Nuclear Information System (INIS)

    Yang, Hyung In; Lee, Dong Soo; Yeo, Jeong Suk; Bae, Sang Kyun; Choi, Chang Woon; Chung, June Key; Lee, Myung Chul; Koh, Chang Soon

    1993-01-01

    Dipyridamole is an agent that may be used to noninvasively evaluate coronary artery disease. The effect of dipyridamole infusion its generally related to its induced peripheral vasodilatory effect. In normal person, heart rate is generally increased slightly while blood pressure decrease, but the achieved double product and related myocardial oxygen consumption have no significant change. The purpose of this study is to examine the effect and side effect of dipyridamole, and to compare different response to dipyridamole among the patients. We evaluated 847 patients who underwent dipyridamole stress myocardial SPECT. 93.6% of them had induced hypotension 0.9% showed no change of blood pressure, 5.5% had increased blood pressure 8.3% had no change of pulse rate more than 10% of basal pulse rate. Among diabetes, 16.9% was not change of pulse rate, 6.7% in non-diabetes. There was no significant correlation between age and rate pressure product rest(RPPr), in patients without perfusion defects on SPECT(y=7.1x+48.4r=0.13 p>0.01). As increasing age, RPPs/RPPr was declined(y=-11.6x+68.9 r=0.17 p<0.01), similar results were obtained in patients with perfusion defect. The size of perfusion defect on myocardial SPECT have no correlation between RPPr and RPPs/RPPr. The side effects of dipyridamole included chest pain and chest tightness, headache, abdominal pain, dizziness, nausea, and dyspnea. As increasing age, dipyridamole-induced cardiac work at rest was increased, cardiac response to dipyridamole was decreased.

  9. Optimization of detector size and collimator for PG-SPECT

    International Nuclear Information System (INIS)

    Ishikawa, M.; Kobayashi, T.; Kanda, K.

    2000-01-01

    A current absorbed dose evaluation method in a Boron Neutron Capture Therapy demands boron reaction rate from a boron concentration of an affected part supposed from a neutron flux and a boron concentration in blood measured by an activation method of a gold wire indirectly and converts it into an absorbed dose. So we devised a PG-SEPCT (Prompt Gamma-ray Single Photon Emission Computed Tomography) system to evaluate an absorbed dose directly by measuring prompt gamma-rays. Ordinary SPECT system uses a big NaI scintillator for detector so that measurement is done in low background gamma-ray environment. However, a conventional detector and collimator system cannot be just applied to PG-SPECT system because a background radiation coexists abundantly (PG-SPECT system is set in irradiation room). Accordingly PG-SPECT system requires a dedicated detector and collimator system. In order to reduce efficiency for background gamma-rays, we arranged detectors in a collimator to shield from background gamma-rays. We examined the most suitable collimator shape. The optimization condition of a dedicated collimator system is as follows: 1) the smallest particle size that can be distinguished is 1 cm. 2) necessary counts at measurement target center is not less than 10,000. (author)

  10. Quantitative Analysis of Regional Cerebral Blood Flow using {sup 99m}Tc-HMPAO SPECT in Parkinson's Disease

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myung Chul; Bae, Sang Kyun; Chung, June Key; Koh, Chang Soon; Roh, Jae Kyu; Myung, Ho Jin [Seoul National University College of Medicine, Seoul (Korea, Republic of); Lee, Myung Hae [Asan Medical Center, Seoul (Korea, Republic of)

    1992-07-15

    Regional cerebral blood flow were measured in 10 patients with Parkinson's disease and 12 normal persons using {sup 99m}Tc-HMPAO SPECT. Reconstructed images were interpreted qualitatively and were compared with those findings of CT. For the quantitative analysis, six pairs of region of interest matched with the perfusion territories of large cerebral arteries and cerebellar hemisphere were determined. From the count values, indices showing the degree of asymmetry between right and left cerebral or cerebellar hemisphere, cerebral asymmetry index (ASI) and percent index of cerebellar asymmetry (PIA), and an index showing change of each region, region to cerebellum ratio (RCR) were obtained. ASI of normal persons and patients were 0.082 +- 0.033 and 0.108 +- 0.062, respectively and PIA were -0.4 +- 0.7% and -0.7 +- 1.0%, respectively, which showed no statistically significant difference between normal persons and patients. Among 10 RCR's, those of both regions of basal ganglia and both regions of anterior cerebral artery were significantly reduced. We concluded that the most significant reduction of regional cerebral blood flow in patients with Parkinson's disease was observed in the regions of basal ganglia and in the regions of anterior cerebral artery, and the degree of change in hemispheric blood flow was similar in both hemisphere.

  11. SPECT in psychiatry; Die Bedeutung der Hirn-SPECT in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Kasper, S [Universitaetsklinik fuer Psychiatrie, Wien (Austria); Gruenwald, F [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin; Danos, P [Psychiatrische Universitaetsklinik, Bonn (Germany); Walter, H [Universitaetsklinik fuer Psychiatrie, Wien (Austria); Klemm, E [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin; Bruecke, T [Universitaetsklinik fuer Neurologie, Wien (Austria); Podreka, I [Universitaetsklinik fuer Neurologie, Wien (Austria); Biersack, H J [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin

    1994-10-01

    In the last fifteen years different attempts have been undertaken to understand the biological basis of major psychiatric disorders. One important tool to determine patterns of brain dysfunction is single emission computed tomography (SPECT). Whereas SPECT investigations are already a valuable diagnostic instrument for the diagnosis of dementia of the Alzheimer Type (DAT) there have not been consistent findings that can be referred to as specific for any other particular psychiatric diagnostic entity. Nevertheless, SPECT studies have been able to demonstrate evidence of brain dysfunction in patients with schizophrenia, depression, anxiety disorders, and substance abuse in which other methods showed no clear abnormality of brain function. Our manuscript reviews the data which are currently available in the literature and stresses the need for further studies, especially for prediction and monitoring psychiatric treatment modalities. (orig.) [Deutsch] In den vergangenen 15 Jahren wurde durch verschiedene methodologische Ansaetze versucht, die biologischen Ursachen psychiatrischer Erkrankungen naeher zu erforschen. Als eine bedeutende Methode hat sich dabei die Single-Photonen-Emissions-Computertomographie (SPECT) herausgestellt. Waehrend die SPECT-Untersuchungen bereits Eingang in die Routinediagnostik bei Demenzen vom Alzheimer-Typ gefunden haben, konnten fuer weitere psychiatrische Erkrankungen noch keine eindeutigen Befunde etabliert werden. Mit der SPECT-Methode ist es jedoch gelungen, funktionelle Veraenderungen des Gehirns von psychiatrischen Erkrankungen darzustellen, wie z.B. Schizophrenie, Depression, Angsterkrankungen bzw. Substanzmissbrauch. In Forschungsprotokollen wird durch die SPECT-Methode versucht, abzuklaeren, inwieweit es moeglich ist, innerhalb der Erkrankungsentitaeten psychiatrischer Erkrankungen oder auch diese uebergreifend eine Subklassifizierung zu finden und evtl. Gehirnsysteme ausfindig zu machen, die mit einer spezifischen

  12. Visualization of portal venous system by single photon emission CT

    Energy Technology Data Exchange (ETDEWEB)

    Kashiwagi, T; Ikawa, T; Azuma, M; Matsuda, H; Yoshioka, H; Mitsutani, N; Koizumi, T

    1987-03-01

    Single photon emission CT (SPECT) was performed for the intra-abdominal blood pool with /sup 99m/Tc autologous red blood cells (RBC) in 15 patients with liver cirrhosis. Twenty mCi of /sup 99m/Tc-RBC labeled by in vivo technique were administered intravenously and tomographic imaging of the intra-abdominal vascular blood pool was performed as follows. For each subject, 64 views were obtained over 360 deg of elliptic rotation at 30 seconds per view using a high resolution low energy parallel-hole collimator. Portal vein and portosystemic collaterals were clearly observed in coronal images. In 12 of 15 patients, portal vein was delineated. Portosystemic collaterals such as coronary vein, splenorenal shunt and umbilical vein were also shown in 12 patients. These images were consistent with images obtained by scintiphotosplenoportography or arterial portography. Therefore, it is considered that SPECT study for the intra-abdominal blood pool is clinically very useful for the diagnosis of abnormality of portal venous system in portal hypertension.

  13. Tl-201 and Tc-99m-DTPA neuro-SPECT in cerebral radiation necrosis

    International Nuclear Information System (INIS)

    Cleto, E.M. Jr.; Holmes, R.A.; Gumerlock, M.K.; Cabeen, M.; Logan, K.W.; Hoffman, T.J.

    1992-01-01

    The results in 3 cases of radiation necrosis demonstrate that by using both radionuclides Tl-201 and Tc-99m-DTPA, one can provide a semi-quantitative method to differentiate recurrent tumor from radiation necrosis. Focally increased cerebral Tl-201 activity in irradiated brain tumor patients is not specific for tumor recurrence, but when used in combination with DTPA, one is able to estimate the amount of Tl-201 activity resulting from increased blood-brain barrier permeability. If the average Tl-201 index is less than the average Tc-99m-DTPA index it suggests that the increased Tl-201 activity results primarily from blood-brain barrier breakdown. Tc-99m-DTPA SPECT, in addition to Tl-201 SPECT, or serial Tl-201 SPECT imaging may increase the accuracy of brain scintigraphy in differentiating radiation necrosis from tumor recurrence. To verify these preliminary findings, we are in the process of analyzing additional SPECT data on 9 more patients with malignant brain tumors. Using a slightly different method of quantifying Tl- 201/Tc-99m-DTPA ratios (computing the ratio of intralesional Tl-201 or Tc-99m-DTPA activity compared to adjacent scalp activity), patients with tumor recurrence have higher Tl-201/Tc-99m-DTPA ratios compared to those with radiation necrosis (verbal communication with Dr. Mary K. Gumerlock). (orig.) [de

  14. Brain perfusion spect imaging with sup 99m Tc-HM-PAO in Parkinson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Wenzhong, Song; Xiangtong, Lin [Shanghai Medical Univ. (China). Huashan Hospital

    1991-02-01

    Forty patients with Parkinson's disease were studied using {sup 99m}Tc-HM-PAO brain perfusion SPECT. 62.5% (25 cases) showed abnormal blood perfusion. Among them 55% showed local decreased blood perfusion of cerebral cortex, 22% showed asymmetric decreased blood perfusion in basal gaglia, 10% showed decreased uptake of tracer in cerebellum. The pathophysiologic basis of the abnormality of brain blood perfusion were briefly discussed.

  15. Tc-99m ECD brain SPECT in MELAS syndrome and mitochondrial myopathy: comparison with MR findings

    International Nuclear Information System (INIS)

    Park, Sang Joon; Ryu, Young Hoon; Jeon, Tae Joo; Kim, Jai Keun; Nam, Ji Eun; Yoon, Pyeong Ho; Yoon, Choon Sik; Lee, Jong Doo

    1998-01-01

    We evaluated brain perfusion SPECT findings of MELAS syndrome and mitochondrial myopathy in correlation with MR imaging in search of specific imaging features. Subjects were five patients (four females and one male; age range, 1 to 25 year) who presented with repeated stroke like episodes, seizures or developmental delay or asymptomatic but had elevated lactic acid in CSF and serum. Conventional non-contrast MR imaging and Tc-99m-ethyl cysteinate dimer (ECD) brain perfusion SPECT were performed and imaging features were analyzed. MRI demonstrated increased T2 signal intensities in the affected areas of gray and white matters mainly in the parietal (4/5) and occipital lobes (4/5) and in the basal ganglia (1/5), which were not restricted to a specific vascular territory. SPECT demonstrated decreased perfusion in the corresponding regions of MRI lesions. In addition, there were perfusion defects in parietal (1 patient), temporal (2), and frontal (1) lobes and basal ganglia (1) and thalami (2). In a patient with mitochondrial myopathy who had normal MRI, decreased perfusion was noted in left parietal area and bilateral thalami. Tc-99m ECD SPECT imaging in patients with MELAS syndrome and mitochondrial myopathy showed hypoperfusion of parieto-occipital cortex, basal ganglia, thalamus and temporal cortex, which were not restricted to a specific vascular territory. There were no specific imaging features on SPECT. The significance of abnormal perfusion on SPECT without corresponding MR abnormalities needs to be evaluated further in larger number of patients

  16. A SPECT study in internal carotid artery occlusion: Discrepancies between flow image and neurologic deficits

    International Nuclear Information System (INIS)

    Moriwaki, H.; Hougaku, H.; Matsuda, I.; Kusunoki, M.; Shirai, J.

    1989-01-01

    A SPECT (single photon emission computed tomography) study in internal carotid artery (ICA) occlusion was performed in 6 patients. The validity of iodoamphetamine (IMP) SPECT study in the evaluation of cerebral blood flow (CBF) or neurologic function is still controversial. In this study, the authors showed several cases in whom SPECT images of brain were not compatible with their neurologic deficits. In 2 typical cases, a large low-density area was observed in the non-dominant hemisphere in computed tomography (CT) scan, but no apparent motor-sensory deficits in left limbs were present. In these patients, SPECT study also revealed flow reduction in the affected side of the brain. So there was a possibility that an IMP brain image could not always reflect CBF, which maintains neurologic function of the brain

  17. Longitudinal evaluation of early dementia of Alzheimer type using brain perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kogure, Daiji; Matsuda, Hiroshi; Ohnishi, Takashi; Kunihiro, Toshiyuki; Uno, Masataka; Asada, Takashi [National Center Hospital for Mental, Nervous, and Muscular Disorders, Kodaira, Tokyo (Japan); Takasaki, Masaru

    1999-02-01

    Regional cerebral blood flow (rCBF) measurements using a Patlak plot method of {sup 99m}Tc-ECD were performed in early dementia of Alzheimer type (DAT) with both HDS-R and MMSE of over 20 to investigate initial abnormality and longitudinal changes of rCBF. A fusion technique of MRI and SPECT images was developed for MRI-guided analysis of regions of interest in hippocampal areas and statistical parametric mapping (SPM) was used for automated and objective approach to analysis of SPECT image data. Seventeen patients with clinically diagnosed early DAT and age-matched 32 normal control subjects were studied. At the first SPECT studies, the mean cerebral blood flow (mCBF) of 38.6{+-}4.7 ml/100 g/min (mean{+-}SD) for early DAT did not show significant reduction as compared with the normal control value of 42.0{+-}3.8, whereas the rCBF values in the bilateral hippocampi (right; 26.8{+-}4.7, left; 26.7{+-}5.2) showed significant reduction (p<0.05) as compared with the normal control values (right; 38.3{+-}4.2, left; 38.4{+-}3.8). The SPM analysis (voxel height; p<0.001, Bonferroni correction; p<0.05) of the first SPECT images revealed significant selective decrease of relative rCBF in the bilateral posterior cingulate gyri. At the second SPECT studies after 1.4 year on the average from the first studies, mCBF for early DAT showed a slight decrease by 1.7{+-}3.8 ml/100 g/min/year. Bilateral hippocampi showed a greater decrease with slight left side dominance by 3.8{+-}3.3 on the right and 4.4{+-}3.2 on the left side. The SPM analysis demonstrated significant decrease of relative rCBF in the basal forebrain area, the left hippocampus, the left amygdala, and the left parahippocampal area. These results suggest that the MRI-guided ROI analysis of rCBF values in the hippocampus and the SPM analysis of SPECT images are quite useful for early diagnosis and follow-up of DAT. (author)

  18. The gated blood pool scan in the evaluation of coronary artery disease

    International Nuclear Information System (INIS)

    Anger, K.; Erbel, R.; Krebs, W.; Meyer, J.; Moeller, T.; Schweizer, P.; Yalkinoglu, O.; Technische Hochschule Aachen

    1983-01-01

    38 patients with clinically suspected coronary artery disease were studied by contrast ventriculography, 2-dimensional echocardiography and multiple gated blood pool imaging (MUGA) without stress. The results were compared with eath other and with the final diagnosis confirmed by coronary angiography. The left ventricular ejection fraction is evaluated nearly identically and with sufficient accuracy by both non-invasive methods, local motion abnormalities are on the other hand diagnosed in the best way by MUGA imaging in our own cases. (orig.) [de

  19. The Diagnostic Efficiency of 99mTc-EDDA/HYNIC-Octreotate SPECT-CT in Comparison with 111In-Pentetrotide in the Detection of Neuroendocrine Tumours

    Directory of Open Access Journals (Sweden)

    Emel Koçyiğit Deveci

    2013-12-01

    Full Text Available Objective: The aim of this study was to assess the diagnostic efficiency of 99mTc-EDDA/HYNIC-Octreotate in comparison with 111Inpentetrotide scintigraphy in the detection of neuroendocrine tumors. This study also evaluates the impact of SPECT-CT hybrid imaging on somatostatin receptor scintigraphy (SRS interpretation and clinical management of these tumors. Methods: Fourteen patients were included in the study. All patients underwent a whole body and SPECT-CT imaging with both 99mTcEDDA/HYNIC-octreotate and 111In-pentetrotide. Images were evaluated both visually and semiquantitatively. Results: On patient basis, the diagnostic results of both studies were similar. The number of lesions detected by 99mTc- EDDA/HYNICOctreotate were higher than the number of lesions detected by 111In-pentetrotide however the difference was not significant (40/43( 93%, 36/43 (83% p=0.109. Semiquantitative analysis showed higher tumor/organ count ratios for both whole-body and SPECT 99mTc- EDDA/HYNIC-Octreotate scans. Conclusion: The results of this study suggested that, 99mTc- EDDA/HYNIC-Octreotate may be a better alternative to 111In- pentetrotide due to high image quality and lower radiation dose. SPECT/CT is a valuable tool for the assessment of neuroendocrine tumors by providing the precise anatomic localization of scintigraphic findings thus improving lesion detectability and characterization.

  20. The Diagnostic Efficiency of 99mTc-EDDA/HYNIC-Octreotate SPECT-CT in Comparison with 111In-Pentetrotide in the Detection of Neuroendocrine Tumours.

    Science.gov (United States)

    Koçyiğit Deveci, Emel; Ocak, Meltem; Bozkurt, Murat Fani; Türker, Selcan; Kabasakal, Levent; Uğur, Omer

    2013-12-01

    The aim of this study was to assess the diagnostic efficiency of (99m)Tc-EDDA/HYNIC-Octreotate in comparison with (111)Inpentetrotide scintigraphy in the detection of neuroendocrine tumors. This study also evaluates the impact of SPECT-CT hybrid imaging on somatostatin receptor scintigraphy (SRS) interpretation and clinical management of these tumors. Fourteen patients were included in the study. All patients underwent a whole body and SPECT-CT imaging with both (99m)Tc- EDDA/HYNIC-octreotate and (111)In-pentetrotide. Images were evaluated both visually and semiquantitatively. On patient basis, the diagnostic results of both studies were similar. The number of lesions detected by (99m)Tc- EDDA/HYNICOctreotate were higher than the number of lesions detected by (111)In-pentetrotide however the difference was not significant (40/43( 93%), 36/43 (83%) p=0.109). Semiquantitative analysis showed higher tumor/organ count ratios for both whole-body and SPECT (99m)Tc- EDDA/HYNIC-Octreotate scans. The results of this study suggested that, (99m)Tc- EDDA/HYNIC-Octreotate may be a better alternative to (111)In- pentetrotide due to high image quality and lower radiation dose. SPECT/CT is a valuable tool for the assessment of neuroendocrine tumors by providing the precise anatomic localization of scintigraphic findings thus improving lesion detectability and characterization. None declared.

  1. A small-animal imaging system capable of multipinhole circular/helical SPECT and parallel-hole SPECT

    International Nuclear Information System (INIS)

    Qian Jianguo; Bradley, Eric L.; Majewski, Stan; Popov, Vladimir; Saha, Margaret S.; Smith, Mark F.; Weisenberger, Andrew G.; Welsh, Robert E.

    2008-01-01

    We have designed and built a small-animal single-photon emission computed tomography (SPECT) imaging system equipped with parallel-hole and multipinhole collimators and capable of circular or helical SPECT. Copper-beryllium parallel-hole collimators suitable for imaging the ∼35 keV photons from the decay of 125 I have been built and installed to achieve useful spatial resolution over a range of object-detector distances and to reduce imaging time on our dual-detector array. To address the resolution limitations in the parallel-hole SPECT and the sensitivity and limited field of view of single-pinhole SPECT, we have incorporated multipinhole circular and helical SPECT in addition to expanding the parallel-hole SPECT capabilities. The pinhole SPECT system is based on a 110 mm diameter circular detector equipped with a pixellated NaI(Tl) scintillator array (1x1x5 mm 3 /pixel). The helical trajectory is accomplished by two stepping motors controlling the rotation of the detector-support gantry and displacement of the animal bed along the axis of rotation of the gantry. Results obtained in SPECT studies of various phantoms show an enlarged field of view, very good resolution and improved sensitivity using multipinhole circular or helical SPECT. Collimators with one, three and five, 1-mm-diameter pinholes have been implemented and compared in these tests. Our objective is to develop a system on which one may readily select a suitable mode of either parallel-hole SPECT or pinhole circular or helical SPECT for a variety of small animal imaging applications

  2. Cerebral blood flow tomography with xenon-133

    DEFF Research Database (Denmark)

    Lassen, N A

    1985-01-01

    computed tomograph (SPECT) is required. Two brain-dedicated SPECT systems designed for this purpose are mentioned, and the method is described with special reference to the limitations inherent in the soft energy of the 133Xe primary photons. CBF tomography can be used for a multitude of clinical...... of other tracers for CBF tomography using SPECT is summarized with emphasis on the 99mTc chelates that freely pass the intact blood-brain barrier. The highly sensitive brain-dedicated SPECT systems described are a prerequisite for achieving high resolution tomograms with such tracers....

  3. Effects of cross talk on dual energy SPECT imaging between [sup 123]I-BMIPP and [sup 201]Tl

    Energy Technology Data Exchange (ETDEWEB)

    Morita, Masato; Narita, Hitoshi; Yamamoto, Juro; Fukutake, Naoshige; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Fukuchi, Minoru (Hyogo College of Medicine, Nishinomiya (Japan))

    1994-01-01

    The study was undertaken to determine how much cross talk influences the visual assessment of dual energy single photon emission computed tomographic (SPECT) images with iodine 123 beta-methyl-p-iodophenylpentadecanoic acid (I-123 BMIPP) and thallium-201 in 15 patients with acute myocardial infarction. After single SPECT with I-123 BMIPP was undertaken, simultaneous dual SPECT with I-123 BMIPP and Tl-201 were undertaken in all patients. Three patients also underwent single SPECT with Tl-201. I-123 BMIPP and Tl-201 uptake was graded in four-score for the comparison between single and dual SPECT images. There was good correlation between dual energy SPECT and both single I-123 BMIPP SPECT (pS=0.97) and single Tl-201 SPECT (pS=0.59). Uptake scores were increased on dual energy SPECT, compared with single I-123 SPECT (8 out of 132 segments) and single Tl-201 SPECT (12 out of 36 segments). Overall, there was a comparatively well correlation between single SEPCT with either I-123 BMIPP or Tl-201 and dual energy SPECT images. However, one tracer uptake sometimes increased in the other tracer defect areas. This was noticeable when I-123 BMIPP exerted an effect on Tl-201. (N.K.).

  4. Indeterminate lesions on planar bone scintigraphy in lung cancer patients: SPECT, CT or SPECT-CT?

    International Nuclear Information System (INIS)

    Sharma, Punit; Kumar, Rakesh; Singh, Harmandeep; Bal, Chandrasekhar; Malhotra, Arun; Julka, Pramod Kumar; Thulkar, Sanjay

    2012-01-01

    The objective of the present study was to compare the role of single photon emission computed tomography (SPECT), computed tomography (CT) and SPECT-CT of selected volume in lung cancer patients with indeterminate lesions on planar bone scintigraphy (BS). The data of 50 lung cancer patients (53 ± 10.3 years; range 30-75; male/female 38/12) with 65 indeterminate lesions on planar BS (January 2010 to November 2010) were retrospectively evaluated. All of them underwent SPECT-CT of a selected volume. SPECT, CT and SPECT-CT images were independently evaluated by two experienced readers (experience in musculoskeletal imaging, including CT: 5 and 7 years) in separate sessions. A scoring scale of 1 to 5 was used, in which 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each modality, taking a score ≤2 as metastatic. With receiver operating characteristic (ROC) curve analysis, areas under the curve (AUC) were calculated for each modality and compared. Clinical and imaging follow-up and/or histopathology were taken as reference standard. For both readers SPECT was inferior to CT (P = 0.004, P = 0.022) and SPECT-CT (P = 0.003, P = 0.037). However, no significant difference was found between CT and SPECT-CT for reader 1 (P = 0.847) and reader 2 (P = 0.592). The findings were similar for lytic as well as sclerotic lesions. Moderate inter-observer agreement was seen for SPECT images (κ = 0.426), while almost perfect agreement was seen for CT (κ = 0.834) and SPECT-CT (κ = 0.971). CT alone and SPECT-CT are better than SPECT for accurate characterisation of indeterminate lesions on planar BS in lung cancer patients. CT alone is not inferior to SPECT-CT for this purpose and might be preferred because of shorter acquisition time and wider availability. (orig.)

  5. Optimum allocation of imaging time and minimum detectable activity in dual isotope blood pool subtraction indium-111 platelet imaging

    International Nuclear Information System (INIS)

    Machac, J.; Horowitz, S.F.; Goldsmith, S.J.; Fuster, V.

    1984-01-01

    Indium-111 labeled platelet imaging is a tool for detection of thrombus formation in vascular spaces. Dual isotope blood pool subtraction may help differentiate focal platelet accumulation from blood pool activity. This study used a computer model to calculate the minimum excess-to-blood pool platelet ratio (EX/BP) and the optimum dual isotope imaging times under varied conditions of lesion size. The model simulated usual human imaging doses of 500 μCi of In-111 platelets and 5mCi of Tc-99m labeled RBCs giving a reference cardiac blood pool region (100cc) of 10000 cpm for Tc-99m and 500 cpm for In-111. The total imaging time was fixed at 20 minutes, while the two isotope imaging times (TIn/TTc) were varied, as were the simulated lesion size (cc) and EX/BP. The relative error of the excess counts was calculated using propagation of error theory. At the critical level of detection, where the excess lesion counts equal 3 times the standard deviation, the optimum TIn/TTc and minimum Ex/BP were determined for each lesion size. For the smallest lesion size (0.1cc), the minimum detectable EX/BP ratio was 1.6, with the best TIn/TTC ratio of 18/2 minutes, and for large lesions, an EX/BP of 0.1, with a TIn/TTc of 16/4. This model provides an estimate of the sensitivity and optimizes imaging times in dual isotope subtraction platelet imaging. The model is adaptable to varying isotope doses, total imaging times and lesion size. This information will be helpful in future in- vivo imaging studies of intravascular thrombi in humans

  6. Predictive value of brain perfusion SPECT for ketamine response in hyperalgesic fibromyalgia

    Energy Technology Data Exchange (ETDEWEB)

    Guedj, Eric; Cammilleri, Serge; Colavolpe, Cecile; Taieb, David; Laforte, Catherine de; Mundler, Olivier [Centre Hospitalo-Universitaire de la Timone, Service Central de Biophysique et de Medecine Nucleaire, Assistance Publique des Hopitaux de Marseille, Marseille Cedex 5 (France); Niboyet, Jean [Clinique La Phoceanne, Unite d' Etude et de Traitement de la Douleur, Marseille (France)

    2007-08-15

    Ketamine has been used successfully in various proportions of fibromyalgia (FM) patients. However, the response to this specific treatment remains largely unpredictable. We evaluated brain SPECT perfusion before treatment with ketamine, using voxel-based analysis. The objective was to determine the predictive value of brain SPECT for ketamine response. Seventeen women with FM (48 {+-} 11 years; ACR criteria) were enrolled in the study. Brain SPECT was performed before any change was made in therapy in the pain care unit. We considered that a patient was a good responder to ketamine if the VAS score for pain decreased by at least 50% after treatment. A voxel-by-voxel group analysis was performed using SPM2, in comparison to a group of ten healthy women matched for age. The VAS score for pain was 81.8 {+-} 4.2 before ketamine and 31.8 {+-} 27.1 after ketamine. Eleven patients were considered ''good responders'' to ketamine. Responder and non-responder subgroups were similar in terms of pain intensity before ketamine. In comparison to responding patients and healthy subjects, non-responding patients exhibited a significant reduction in bilateral perfusion of the medial frontal gyrus. This cluster of hypoperfusion was highly predictive of non-response to ketamine (positive predictive value 100%, negative predictive value 91%). Brain perfusion SPECT may predict response to ketamine in hyperalgesic FM patients. (orig.)

  7. Predictive value of brain perfusion SPECT for ketamine response in hyperalgesic fibromyalgia

    International Nuclear Information System (INIS)

    Guedj, Eric; Cammilleri, Serge; Colavolpe, Cecile; Taieb, David; Laforte, Catherine de; Mundler, Olivier; Niboyet, Jean

    2007-01-01

    Ketamine has been used successfully in various proportions of fibromyalgia (FM) patients. However, the response to this specific treatment remains largely unpredictable. We evaluated brain SPECT perfusion before treatment with ketamine, using voxel-based analysis. The objective was to determine the predictive value of brain SPECT for ketamine response. Seventeen women with FM (48 ± 11 years; ACR criteria) were enrolled in the study. Brain SPECT was performed before any change was made in therapy in the pain care unit. We considered that a patient was a good responder to ketamine if the VAS score for pain decreased by at least 50% after treatment. A voxel-by-voxel group analysis was performed using SPM2, in comparison to a group of ten healthy women matched for age. The VAS score for pain was 81.8 ± 4.2 before ketamine and 31.8 ± 27.1 after ketamine. Eleven patients were considered ''good responders'' to ketamine. Responder and non-responder subgroups were similar in terms of pain intensity before ketamine. In comparison to responding patients and healthy subjects, non-responding patients exhibited a significant reduction in bilateral perfusion of the medial frontal gyrus. This cluster of hypoperfusion was highly predictive of non-response to ketamine (positive predictive value 100%, negative predictive value 91%). Brain perfusion SPECT may predict response to ketamine in hyperalgesic FM patients. (orig.)

  8. ATP-loading 201Tl myocardial SPECT for the detection of ischemic heart disease

    International Nuclear Information System (INIS)

    Fujinaga, Tsuyoshi; Yamazaki, Sayaka; Hara, Masatada; Umezawa, Chiaki; Okamura, Tetsuo; Murata, Hajime; Maruno, Hirotaka; Onoguchi, Masahisa.

    1993-01-01

    To evaluate the usefulness for the detection of ischemic heart disease, ATP myocrdial SPECT was performed in 35 patients (mean; 59±9.4 years) with angina pectoris or old myocardial infarction. Coronary angiography (CAG) was performed in all patients. The ultra-short half-life of ATP required a continuous infusion for its use. ATP was infused intravenously at a rate of 0.16 mg/kg/min for 5 min, with 201 Tl injection taking place at 3 min. Myocardial SPECT imaging was begun 5 min and 4 hr later after the end of ATP infusion. ATP caused a significant decrease in arterial blood pressure (p 201 Tl myocardial SPECT for the detection of coronary artery disease (CAD) was evaluated using CAG as a golden standard. The sensitivity and specificity for CAD detection were 82% and 90%, respectively. ATP myocardial SPECT is a promising new test for the detection of ischemic heart disease. (author)

  9. The application of PET, SPECT and MRS in Parkinson's disease

    International Nuclear Information System (INIS)

    Dong Aisheng; Tian Jianming

    2005-01-01

    PET and SPECT provide the means to studying in vivo the neurochemical, hemodynamic or metabolic consequences of the degeneration of the nigrostriatal dopamineric system in Parkinson's disease (PD). Activation studies using cerebral blood flow and metabolism measurements during a motor task reveal an impaired ability to activate the supplementary motor area and dorsolateral prefrontal cortex in PD. The extent of striatal dopaminergic denervation can be quantified with PET and SPECT. Striatal uptake of 18 F-dopa is markedly decreased in PD, more in the putamen than in the caudate nucleus, and inversely correlates with the severity of motor signs and with duration of disease. PET and SPECT make possible the assessment by noninvasive means of the changes in dopamine receptor density. Meanwhile, MRS can reveal changes in concentration of several hydrogenate and phosphoric compounds in the brain. The functional information of brain in PD can be obtained with these complementary techniques. (authors)

  10. Ictal and interictal SPECT imaging of 8 patients with symptomatic partial epilepsy

    International Nuclear Information System (INIS)

    Motooka, Hiromichi

    1993-01-01

    Although epileptic discharges such as spike, spike and wave complex, sharp wave, and sharp and wave complex can be recorded by interictal scalp electroencephalography (EEG) in many patients with epilepsy, recent studies have demonstrated that no epileptic discharges can be recorded by interictal and ictal scalp EEGs in some patients who clinically exhibit epileptic seizures. Accordingly scalp EEG is not always helpful for diagnosing epilepsy or identifying the epileptic foci in the brain in these patients. Recently, studies using single photon emission computed tomography (SPECT) have been performed for patients with epilepsy and evidence that epileptic foci can be identified by changes in the regional cerebral blood flow (rCBF) seen on SPECT scanning have been accumulated. In the present study, therefore, 8 patients with medically intractable partial seizures were simultaneously or independently investigated by the recordings of scalp EEG and SPECT scanning during the interictal and ictal period. N-isopropyl-p[ 123 I]-iodoamphetamine ( 123 I-IMP) was used for SPECT scanning for 7 patients and 99m Tc-d,l-hexamethyl-propyleneamineoxime ( 99m Tc-HMPAO) for 1 patient. An increase in rCBF (hyperperfusion) or decrease in rCBF (hypoperfusion) were found in 4 patients by interictal SPECT imaging and in all patients by ictal SPECT imaging although epileptic discharges were observed in 3 patients by interictal scalp EEG and 5 patients by ictal scalp EEG. The findings of the present study indicate that ictal SPECT scanning is more useful for diagnosing epilepsy and identifying the epileptic foci in the brain than ictal scalp EEG. (author)

  11. Assessment of technetium-99m technegas scintigraphy for ventilatory impairment in pulmonary emphysema. Comparison of planar and SPECT images

    International Nuclear Information System (INIS)

    Satoh, Katashi; Tanabe, Masatada; Takahashi, Kazue

    1997-01-01

    Pulmonary emphysema can be diagnosed easily by X-ray CT (CT) as a low attenuation area. Recently Tc-99m-Technegas (Technegas) has been used for ventilation scintigraphy. The present study was undertaken to assess the usefulness of planar and SPECT images by using Technegas scintigraphy in patients with pulmonary emphysema. Technegas scintigraphy, CT and pulmonary function tests were performed in 20 patients (males, age 32-78 years). We classified the findings of Technegas images into 4 grades. Comparing planar and SPECT images of Technegas, more detailed findings were shown by SPECT than by planar images in mild cases (6 cases, 30%). In more severe cases, findings of SPECT and planar images were equivalent (14 cases, 70%). The degree of abnormal findings obtained by SPECT was equivalent to that obtained by CT in severe cases (6 cases, 30%). SPECT should be excluded in advanced stages as indicated by planar images. (author)

  12. Evaluation of regional cerebral blood flow changes in normal aging using 99mTc-ECD SPECT and Patlak method

    International Nuclear Information System (INIS)

    Mizuno, Shinji; Nandate, Yuka; Enya, Mayumi; Manabe, Tomoko; Goto, Hiroo; Hoshi, Hiroaki; Takahashi, Yukitoshi; Kato, Zenichiro; Kondo, Naomi

    1998-01-01

    Changes in regional cerebral blood flow (rCBF) were studied using 99m Tc-ECD SPECT and Patlak method in 47 subjects, aged 1 to 79 years (mean 28.5 years). No abnormal finding was found on MR imaging in the subjects. We obtained mean cerebral blood flow (mCBF) by means of Patlak method. rCBF was measured by positioning regions of interest (ROIs) in frontal lobe, parietal lobe, temporal lobe, occipital lobe, cerebellum and thalamus. The correlation coefficient between ages and mCBF was r=-0.897 (p<0.0001). mCBF of children was significantly higher (p<0.05), compared with adults. By dispersion analysis according to the groups of ages, significantly higher rCBF values were available in the frontal, parietal, temporal and occipital lobes during childhood than adulthood (p<0.05), but there were almost no significant differences of rCBF during childhood than adulthood in cerebellum and thalamus. (author)

  13. A study on measurement of the regional cerebral blood flow using autoradiographic method in moyamoya disease

    International Nuclear Information System (INIS)

    Sasaki, Tomohiro; Kiya, Katsuzo; Yuki, Kiyoshi; Kawamoto, Hitoshi; Mizoue, Tatsuya; Kiura, Yoshihiro; Uozumi, Tohru; Ikawa, Fusao

    1997-01-01

    Development of Autoradiographic method (ARG) has provided measurement of cerebral blood flow in moyamoya disease. We evaluate a cerebral vasodilatory capacity (CVC) for moyamoya disease using ARG method. We used 5 patients with moyamoya disease as a candidate for measurement of the cerebral blood flow (CBF) who admitted to Hiroshima Prefectural Hospital during the past one year. There were 3 patients in an adult age and 2 patients in a young age. We tried to measure the regional CBF (rCBF) using ARG method which was a easy way to estimate the rCBF on SPECT. The CVC was calculated from the difference of the rCBF between resting SPECT and Diamox-loading SPECT. Results were as follows; Reactivity of cerebral vessels to CO 2 loading and CVC weakened in moyamoya disease. The rCBF and CVC in the territories of anterior and middle cerebral arteries reduced in comparison with those in the area supplied by the posterior cerebral artery. The CVC at the treated side with surgical reconstruction recovered somewhat in an adult type. From these results, measurement of CBF using ARG method seems to be useful for evaluation of the CVC in moyamoya disease. (author)

  14. Task Equivalence for Model and Human-Observer Comparisons in SPECT Localization Studies

    Science.gov (United States)

    Sen, Anando; Kalantari, Faraz; Gifford, Howard C.

    2016-06-01

    While mathematical model observers are intended for efficient assessment of medical imaging systems, their findings should be relevant for human observers as the primary clinical end users. We have investigated whether pursuing equivalence between the model and human-observer tasks can help ensure this goal. A localization receiver operating characteristic (LROC) study tested prostate lesion detection in simulated In-111 SPECT imaging with anthropomorphic phantoms. The test images were 2D slices extracted from reconstructed volumes. The iterative ordered sets expectation-maximization (OSEM) reconstruction algorithm was used with Gaussian postsmoothing. Variations in the number of iterations and the level of postfiltering defined the test strategies in the study. Human-observer performance was compared with that of a visual-search (VS) observer, a scanning channelized Hotelling observer, and a scanning channelized nonprewhitening (CNPW) observer. These model observers were applied with precise information about the target regions of interest (ROIs). ROI knowledge was a study variable for the human observers. In one study format, the humans read the SPECT image alone. With a dual-modality format, the SPECT image was presented alongside an anatomical image slice extracted from the density map of the phantom. Performance was scored by area under the LROC curve. The human observers performed significantly better with the dual-modality format, and correlation with the model observers was also improved. Given the human-observer data from the SPECT study format, the Pearson correlation coefficients for the model observers were 0.58 (VS), -0.12 (CH), and -0.23 (CNPW). The respective coefficients based on the human-observer data from the dual-modality study were 0.72, 0.27, and -0.11. These results point towards the continued development of the VS observer for enhancing task equivalence in model-observer studies.

  15. Gated blood pool study in one case of endocarditis parietalis fibroplastica LOEFFLER - a case report

    Energy Technology Data Exchange (ETDEWEB)

    Feistel, H; Mahlstedt, J; Wolf, F

    1983-10-01

    The rare case of endocarditis parietalis fibroplastica Loeffler is described. In laevocardiography this kind of endomyocardfibrose, in our patient combined with excessive blood eosinophilia of 86%, presents a typical diastolic-systolic contraction pattern. Gated blood pool study matches well with the results of contrast angiography. Exercise-testing provoked an EF increase of from 48% to 55%, excluding CAD. Clinical complaints are not specific, caused by extreme restriction of myocardial compliance with high left ventricular filling pressure and subsequent mean pulmonary hypertonus. The patient died before the operative intervention in sudden heart death.

  16. Gated blood pool study in one case of endocarditis parietalis fibroplastica LOEFFLER - a case report

    International Nuclear Information System (INIS)

    Feistel, H.; Mahlstedt, J.; Wolf, F.

    1983-01-01

    The rare case of endocarditis parietalis fibroplastica Loeffler is described. In laevocardiography this kind of endomyocardfibrose, in our patient combined with excessive blood eosinophilia of 86%, presents a typical diastolic-systolic kontraction pattern. Gated blood pool study matches well with the results of contrast angiography. Exercise-testing provoked an EF increase of from 48% to 55%, excluding CAD. Clinical complaints are not specific, caused by extreme restriction of myocardial compliance with high left ventricular filling pressure and subsequent mean pulmonary hypertonus. The patient died before the operative intervention in sudden heart death. (orig.) [de

  17. Implementation and Evaluation of Pinhole SPECT

    International Nuclear Information System (INIS)

    MacArtain Anne Marie

    2002-08-01

    The aim of this work was to implement Pinhole SPECT into a working Nuclear Medicine department. It has been reported that pinhole SPECT has been successfully performed to visualise pathology in ankle bones using gamma camera and the images were constructed using a standard filtered back-projection algorithm (Bahk YW, 1998). The objective of this study was to produce and evaluate this technique with the equipment available in the nuclear medicine department. The system performance was assessed using both the low-energy high resolution and the pinhole collimators. Phantoms constructed using capillary tubes, filled with technetium 99m (pertechnetate) were imaged in different arrays to identify possible limitations in the reconstruction software. A thyroid phantom with hot and cold inserts was also imaged. Data was acquired in ''tep-and-shoot'' mode as the camera was rotated 180 degrees or 360 degrees around the phantom. Images were reconstructed using standard parallel back-projection algorithm and a weighted backprojection algorithm (Nowak). An attempt was made to process images of the phantom in Matlab using the Iradon function modified by application of a cone-beam type algorithm (Feldkamp L, 1984). Visual comparison of static images between the pinhole and the LEHR collimators showed the expected improved spatial resolution of the pinhole images. Pinhole SPECT images should be reconstructed using the appropriate cone beam algorithm. However, it was established that reconstructing pinhole SPECT images using a standard parallel backprojection algorithm yielded results which were deemed to be clinically useful. The Nowak algorithm results were a distinct improvement on those achieved with the parallel backprojection algorithm. Likewise the results from the cone beam algorithm were better than the former but not as good as those obtained from the Nowak algorithm. This was due to the fact that the cone beam algorithm did not include a weighting factor. Implementation

  18. Comparison of SPECT/CT, MRI and CT in diagnosis of skull base bone invasion in nasopharyngeal carcinoma.

    Science.gov (United States)

    Zhang, Shu-xu; Han, Peng-hui; Zhang, Guo-qian; Wang, Rui-hao; Ge, Yong-bin; Ren, Zhi-gang; Li, Jian-sheng; Fu, Wen-hai

    2014-01-01

    Early detection of skull base invasion in nasopharyngeal carcinoma (NPC) is crucial for correct staging, assessing treatment response and contouring the tumor target in radiotherapy planning, as well as improving the patient's prognosis. To compare the diagnostic efficacy of single photon emission computed tomography/computed tomography (SPECT/CT) imaging, magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of skull base invasion in NPC. Sixty untreated patients with histologically proven NPC underwent SPECT/CT imaging, contrast-enhanced MRI and CT. Of the 60 patients, 30 had skull base invasion confirmed by the final results of contrast-enhanced MRI, CT and six-month follow-up imaging (MRI and CT). The diagnostic efficacy of the three imaging modalities in detecting skull base invasion was evaluated. The rates of positive findings of skull base invasion for SPECT/CT, MRI and CT were 53.3%, 48.3% and 33.3%, respectively. The sensitivity, specificity and accuracy were 93.3%, 86.7% and 90.0% for SPECT/CT fusion imaging, 96.7%, 100.0% and 98.3% for contrast-enhanced MRI, and 66.7%, 100.0% and 83.3% for contrast-enhanced CT. MRI showed the best performance for the diagnosis of skull base invasion in nasopharyngeal carcinoma, followed closely by SPECT/CT. SPECT/CT had poorer specificity than that of both MRI and CT, while CT had the lowest sensitivity.

  19. SPECT og PET i neurobiologien

    DEFF Research Database (Denmark)

    Paulson, O.B.; Lassen, N.A.

    1997-01-01

    PET (positron emission tomography) and SPECT (single photon emission computed tomography) are isotopic methods in which the distribution is registered of radiolabelled tracers given in such small amounts that they are without effect on the organism or the organism's disposal of them. Thus, a series...... of important biological processes in the intact organism can be studied. The methods have been used in many disciplines but in particular for neurobiological research on the brain--e.g., the brain's regional blood circulation and mapping of the brain's functional structure. The methods have also been used...

  20. Assessing the performance of multiplexed tandem PCR for the diagnosis of pathogenic genotypes of Theileria orientalis using pooled blood samples from cattle.

    Science.gov (United States)

    Gebrekidan, Hagos; Gasser, Robin B; Stevenson, Mark A; McGrath, Sean; Jabbar, Abdul

    2017-02-01

    Oriental theileriosis caused by multiple genotypes of Theileria orientalis is an important tick-borne disease of bovines. Here, we assessed the performance of an established multiplexed tandem PCR (MT-PCR) for the diagnosis of the two recognized, pathogenic genotypes (chitose and ikeda) of T. orientalis in cattle using pooled blood samples. We used a total of 265 cattle blood samples, which were divided into two groups according to previous MT-PCR results for individual samples. Samples in group 1 (n = 155) were from a herd with a relatively high prevalence of T. orientalis infection; and those in group 2 (n = 110) were from four herds with a low prevalence. For group 1, 31 and 15 batches of five- and ten-pooled samples (selected at random), respectively, were formed. For group 2, 22 and 11 batches of five- and ten-pooled samples (selected at random), respectively, were formed. DNAs from individual pooled samples in each batch and group were then tested by MT-PCR. For group 1, the apparent prevalences estimated using the 31 batches of five-pooled samples (97%) and 15 batches of ten-pooled samples (100%) were significantly higher compared with individual samples (75%). For group 2, higher apparent prevalences (9% and 36%) were also recorded for the 22 and 11 batches of pooled samples, respectively, compared with individual samples (7%). Overall, the average infection intensity recorded for the genotypes of chitose and ikeda were considerably lower in pooled compared with individual samples. The diagnostic specificities of MT-PCR were estimated at 95% and 94%, respectively, when batches of five- and ten-pooled samples were tested, and 94% for individual samples. The diagnostic sensitivity of this assay was estimated at 98% same for all individual, five- and ten-pooled samples. This study shows that screening batches of five- and ten-pooled blood samples from cattle herds are similar to those obtained for individual samples, and, importantly, that the reduced cost

  1. SPECT/CT image fusion with 99mTc-HYNIC-TOC in the oncological diagnostic

    International Nuclear Information System (INIS)

    Haeusler, F.

    2006-07-01

    Neuroendocrine tumours displaying somatostatin receptors have been successfully visualized with somatostatin receptor imaging. The aim of this retrospective study was to evaluate the value of anatomical-functional image fusion. Image fusion means the combined transmission and emission tomography (computed tomography (CT)) and single-photon emission computed tomography (SPECT) ) and was analyzed in comparison with SPECT and CT alone. Fifty-three patients (30 men and 23 women; mean age 55,9 years; range: 20-82 years) with suspected or known endocrine tumours were studied. The patients were referred to image fusion because of staging of newly diagnosed tumours (14) or biochemically/clinically suspected neuroendocrine tumour (20) or follow-up studies after therapy (19). The patients were studied with SPECT at 2 and 4 hours after injection of 400 MBq of 99mTc-EDDA-HYNIC-Tyr3-octreotide using a dual-detector scintillation camera. The CT was performed on one of the following two days. For both investigations the patients were fixed in an individualized vacuum mattress to guarantee exactly the same position. SPECT and SPECT/CT showed an equivalent scan result in 35 patients (66 %), discrepancies were found in 18 cases (34 %). After image fusion the scan result was true-positive in 27 patients ( 50.9 %) and true-negative in 25 patients (47.2 %). One patient with multiple small liver metastases escaped SPECT as well as image fusion and was so false-negative. The frequency of equivocal and probable lesion characterization was reduced by 11.6% (12 to 0) with PET/CT in comparison with PET or CT alone. The frequency of definite lesion characterization was increased by 11.6% (91 to 103). SPECT/CT affected the clinical management in 21 patients (40 %). The results of this study indicate that SPECT/CT is a valuable tool for the assessment of neuroendocrine tumours. SPECT/CT is better than SPECT or CT alone and it allows a more precise staging and determination of prognosis and

  2. Comparative study of FDG-PET and sestamibi-SPECT in the diagnosis of secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Higuchi, T.; Ozawa, K.; Oriuchi, N.; Khan, N.; Endo, K.; Otake, H.; Matsubara, K.

    2002-01-01

    Aim: FDG-PET is reported to be more accurate in preoperative localization of hyper functioning parathyroid gland of primary hyperparathyroidism in comparison with sestamibi-SPECT by Neumann et al. However, its usefulness in the diagnosis of secondary hyperparathyroidism has not been reported yet. In this study, we've performed the direct comparison of the usefulness of FDG-PET and sestamibi-SPECT in the detection of abnormal parathyroid tissue in the patients of secondary hyperparathyroidism under hemodilysis. Material and Methods: One primary and 5 secondary hyperparathyroidism patients underwent FDG-PET and sestamibi-SPECT. After overnight fasting, 300 to 400 MBq of FDG was intravenously injected, followed by whole body PET image acquisition after 50 minutes. In the same day before FDG-PET, 600 MBq of sestamibi was injected and early and delayed planar image and delayed SPECT image has been obtained. Visual interpretation of the abnormal parathyroid uptake has been performed by 2 experienced nuclear physician independently. Results: In the secondary cases, FDG-PET shows no hyper functioning gland in all 5 cases, whereas sestamibi-SPECT shows 8 hyper functioning glands. In contrast, hyper functioning gland of the primary hyperparathyroidism case has been clearly visualized only by FDG-PET. Conclusion: Although FDG-PET is very useful in detecting hyper functioning gland in primary hyperparathyroidism, it is not useful in secondary hyperparathyroidism. Further pathological analysis about the different glucose metabolism of primary and secondary hyper functioning gland should be added in the future study

  3. Routine measurements of left and right ventricular output by gated blood pool emission tomography in comparison with thermodilution measurements: a preliminary study

    International Nuclear Information System (INIS)

    Mariano-Goulart, D.; Boudousq, V.; Comte, F.; Eberle, M.C.; Zanca, M.; Kotzki, P.O.; Rossi, M.; Piot, C.; Raczka, F.; Davy, J.M.

    2001-01-01

    The aim of this preliminary study was to evaluate the accuracy of left and right ventricular output computed from a semi-automatic processing of tomographic radionuclide ventriculography data (TRVG) in comparison with the conventional thermodilution method. Twenty patients with various heart diseases were prospectively included in the study. Thermodilution and TRVG acquisitions were carried out on the same day for all patients. Analysis of gated blood pool slices was performed using a watershed-based segmentation algorithm. Right and left ventricular output measured by TRVG correlated well with the measurements obtained with thermodilution (r=0.94 and 0.91 with SEE=0.38 and 0.46 l/min, respectively, P<0.001). The limits of agreement for TRVG and thermodilution measurements were -0.78-1.20 l/min for the left ventricle and -0.34-1.16 l/min for the right ventricle. No significant difference was found between the results of TRVG and thermodilution with respect to left ventricular output (P=0.09). A small but significant difference was found between right ventricular output measured by TRVG and both left ventricular output measured by TRVG (mean difference=0.17 l/min, P=0.04) and thermodilution-derived cardiac output (mean difference=0.41 l/min, P=0.0001). It is concluded that the watershed-based semi-automatic segmentation of TRVG slices provides non-invasive measurements of right and left ventricular output and stroke volumes at equilibrium, in routine clinical settings. Further studies are necessary to check whether the accuracy of these measurements is good enough to permit correct assessment of intracardiac shunts. (orig.)

  4. Quantifying regional cerebral blood flow with N-isopropyl-p-[123I]iodoamphetamine and SPECT by one-point sampling method

    International Nuclear Information System (INIS)

    Odano, Ikuo; Takahashi, Naoya; Noguchi, Eikichi; Ohtaki, Hiro; Hatano, Masayoshi; Yamazaki, Yoshihiro; Higuchi, Takeshi; Ohkubo, Masaki.

    1994-01-01

    We developed a new non-invasive technique; one-point sampling method, for quantitative measurement of regional cerebral blood flow (rCBF) with N-isopropyl-p-[ 123 I]iodoamphetamine and SPECT. Although the continuous withdrawal of arterial blood and octanol treatment of the blood are required in the conventional microsphere method, the new technique dose not require these two procedures. The total activity of 123 I-IMP obtained by the continuous withdrawal of arterial blood is inferred by the activity of 133 I-IMP obtained by the one point arterial sample using a regression line. To determine when one point sampling time was optimum for inferring integral input function of the continuous withdrawal and whether the treatment of sampled blood for octanol fraction was required, we examined a correlation between the total activity of arterial blood withdrawn from 0 to 5 min after the injection and the activity of one point sample obtained at time t, and calculated a regression line. As a result, the minimum % error for the inference using the regression line was obtained at 6 min after the 123 I-IMP injection, moreover, the octanol treatment was not required. Then examining an effect on the values of rCBF when the sampling time was deviated from 6 min, we could correct the values in approximately 3% error when the sample was obtained at 6±1 min after the injection. The one-point sampling method provides accurate and relatively non-invasive measurement of rCBF without octanol extraction of arterial blood. (author)

  5. Comparison of acetazolamide-enhanced brain SPECT using Tc-99m ECD with cerebral angiography in patients with cerebrovascular disease

    International Nuclear Information System (INIS)

    Choi, Y. Y.; Moon, D. H.; Ryu, J. S.; Yang, S. H.; Lee, H. K.; Lee, J. H.; Kim, J. S.; Kim, K. A.

    1997-01-01

    Cerebral vascular reserve can be assessed by development of collateral channels (DCC) on cerebral angiography(CA) or vasoreactivity (VR) on acetazolamide-enhanced brain SPECT (ACZ-SPECT). The purpose of this study was to compare Tc-99m ECD ACZ-SPECT with CA in the evaluation of vascular reserve in patients (pts) with cerebrovascular disease(CVD). Twenty seven patients with CVD, including TIA (n=13), infarction (n=11) and asymptomatic pts (AS, n=3), underwent CA and ACZ-SPECT. Basal and ACZ-SPECT was obtained consecutively, and image subtraction was performed. On CA, degree of DCC was scored 0-3 (0: normal, 3: poor) according to parenchymal staining on delayed film. In ACZ-SPECT, decrease of VR was graded 0-3 (0: normal, 3: more than 30% decrease). The correlation between degree of stenosis, DCC and VR were analyzed. 1) Variable degree of VR or DCC was observed in totally occluded or stenotic cerebral arterial territories. 2) In arterial territories with poor DCC, ACZ-SPECT showed poor VR. However, in 5 out of 11 TIA or AS with good DCC, poor VR was observed. These data suggests that 1) cerebral hemodynamic status cannot be assessed by the degree of stenosis on CA alone. 2) DCC may overestimate the cerebral vascular reserve in patients with TIA or AS. 3) ACZ-SPECT plays a complementary role to CA for evaluation of cerebral hemodynamic status in pts with CVD

  6. Multiaxial tomography of heart chambers by gated blood-pool emission computed tomography using a rotating gamma camera

    International Nuclear Information System (INIS)

    Tamaki, N.; Mukai, T.; Ishii, Y.; Yonekura, Y.; Yamamoto, K.; Kadota, K.; Kambara, H.; Kawai, C.; Torizuka, K.

    1983-01-01

    Fifteen patients and three volunteers underwent radionuclide blood-pool cardiac studies with electrocardiographic gating. Following conventional planar-gated imaging (anterior and left anterior oblique projections), emission computed tomography (ECT), using a rotating gamma camera, was performed.A series of transaxial tomograms of the cardiac chambers was obtained. The left ventricular short-axis plane, long-axis plane, and four-chamber-view plane were then reorganized; each chamber was visualized separately. Compared to gated planar imaging, this technique showed regional asynergy more clearly in patients with myocardial infarction and demonstrated dilatation of the atria and ventricles more accurately in patients with an atrial septal defect and valvular heart diseases. In addition, when a section of the heart is otained at any angle with gated blood pool ECT, three-dimensional assessment of cardiac chambers in motion is more precise; mutual superimposition becomes unnecessary

  7. Relationship between cognitive function and regional cerebral blood flow in stroke patients using 99mTc-ECD SPECT 3DSRT

    International Nuclear Information System (INIS)

    Sasaki, Nobuyuki; Abo, Masahiro

    2006-01-01

    The purpose of this study was to investigate the associations between regional cerebral blood flow (rCBF) and cognitive function in patients having a local stroke within the thalamus or putamen. The Mini-Mental State Examination (MMSE) and the Kohs Block Design Test (KBDT) were used to evaluate cognitive function. Brain single-photon emission computed tomography (SPECT) was performed with 99m Tc-ethyl cysteinate dimer and analyzed with a 3-dimensional stereotactic region-of-interest template. Subjects were divided into subgroups according to the total MMSE score (D [Dementia: 23 points or less] and N [Normal: 24 points or more]) and according to KBDT scores (B [Bad: less than IQ 70] and G [Good: IQ 70 or more]). The rCBF was decreased in the MMSE D subgroup, especially in patients with a left putamen lesion, and in the KBDT B subgroup, especially in patients with a left thalamus lesion. When the lesion was in the right hemisphere, no significant difference in rCBF was found between the MMSE D and N subgroups or between the KBDT B and G subgroups. SPECT is useful for clinical evaluation of cerebral vascular disease, especially in patients with left hemispheric lesions. Additional data and further detailed evaluations are needed. (author)

  8. SPECT-imaging of activity-dependent changes in regional cerebral blood flow induced by electrical and optogenetic self-stimulation in mice.

    Science.gov (United States)

    Kolodziej, Angela; Lippert, Michael; Angenstein, Frank; Neubert, Jenni; Pethe, Annette; Grosser, Oliver S; Amthauer, Holger; Schroeder, Ulrich H; Reymann, Klaus G; Scheich, Henning; Ohl, Frank W; Goldschmidt, Jürgen

    2014-12-01

    Electrical and optogenetic methods for brain stimulation are widely used in rodents for manipulating behavior and analyzing functional connectivities in neuronal circuits. High-resolution in vivo imaging of the global, brain-wide, activation patterns induced by these stimulations has remained challenging, in particular in awake behaving mice. We here mapped brain activation patterns in awake, intracranially self-stimulating mice using a novel protocol for single-photon emission computed tomography (SPECT) imaging of regional cerebral blood flow (rCBF). Mice were implanted with either electrodes for electrical stimulation of the medial forebrain bundle (mfb-microstim) or with optical fibers for blue-light stimulation of channelrhodopsin-2 expressing neurons in the ventral tegmental area (vta-optostim). After training for self-stimulation by current or light application, respectively, mice were implanted with jugular vein catheters and intravenously injected with the flow tracer 99m-technetium hexamethylpropyleneamine oxime (99mTc-HMPAO) during seven to ten minutes of intracranial self-stimulation or ongoing behavior without stimulation. The 99mTc-brain distributions were mapped in anesthetized animals after stimulation using multipinhole SPECT. Upon self-stimulation rCBF strongly increased at the electrode tip in mfb-microstim mice. In vta-optostim mice peak activations were found outside the stimulation site. Partly overlapping brain-wide networks of activations and deactivations were found in both groups. When testing all self-stimulating mice against all controls highly significant activations were found in the rostromedial nucleus accumbens shell. SPECT-imaging of rCBF using intravenous tracer-injection during ongoing behavior is a new tool for imaging regional brain activation patterns in awake behaving rodents providing higher spatial and temporal resolutions than 18F-2-fluoro-2-dexoyglucose positron emission tomography. Copyright © 2014 The Authors

  9. A simple method for measurement of cerebral blood flow using 123I-IMP SPECT with calibrated standard input function by one point blood sampling. Validation of calibration by one point venous blood sampling as a substitute for arterial blood sampling

    International Nuclear Information System (INIS)

    Ito, Hiroshi; Akaizawa, Takashi; Goto, Ryoui

    1994-01-01

    In a simplified method for measurement of cerebral blood flow using one 123 I-IMP SPECT scan and one point arterial blood sampling (Autoradiography method), input function is obtained by calibrating a standard input function by one point arterial blood sampling. A purpose of this study is validation of calibration by one point venous blood sampling as a substitute for one point arterial blood sampling. After intravenous infusion of 123 I-IMP, frequent arterial and venous blood sampling were simultaneously performed on 12 patients of CNS disease without any heart and lung disease and 5 normal volunteers. The radioactivity ratio of venous whole blood which obtained from cutaneous cubital vein to arterial whole blood were 0.76±0.08, 0.80±0.05, 0.81±0.06, 0.83±0.11 at 10, 20, 30, 50 min after 123 I-IMP infusion, respectively. The venous blood radioactivities were always 20% lower than those of arterial blood radioactivity during 50 min. However, the ratio which obtained from cutaneous dorsal hand vein to artery were 0.93±0.02, 0.94±0.05, 0.98±0.04, 0.98±0.03, at 10, 20, 30, 50 min after 123 I-IMP infusion, respectively. The venous blood radioactivity was consistent with artery. These indicate that arterio-venous difference of radioactivity in a peripheral cutaneous vein like a dorsal hand vein is minimal due to arteriovenous shunt in palm. Therefore, a substitution by blood sampling from cutaneous dorsal hand vein for artery will be possible. Optimized time for venous blood sampling evaluated by error analysis was 20 min after 123 I-IMP infusion, which is 10 min later than that of arterial blood sampling. (author)

  10. Comparison of myocardial function between post-menopausal and pre-menopausal women: evaluation by gated myocardial SPECT

    International Nuclear Information System (INIS)

    Hwang, K. H.; Choa, Won Sick; Yoon, Min Ki

    2005-01-01

    In addition to inhibiting coronary atherosclerosis, estrogen is expected to have protective effects on cardiac myocytes. We investigated the difference in myocardial functional parameters evaluated by gated myocardial SPECT after adenosine-stress between post-menopausal and pre-menopausal healthy women. This study included 22 healthy post-menopausal women (mean age: 53.0 yr) and 20 pre-menopausal women (mean age: 43.0 yr) who performed Tc-99m tetrofosmin gated myocardial SPECT after adenosine-stress. Measured hemodynamic parameters, EDV, ESV, stroke volume, EF, cardiac output and cardiac index were compared between the two groups. For comparison, similar-aged two male groups with matched numbers were also studied. There was no significant difference in hemodynamic parameters. EDV, ESV, stroke volume, EF, or cardiac output between the post-menopausal and pre-menopausal women. However, post-menopausal women have a smaller cardiac index (mean: 1.95 L/min/m2 vs 2.20 L/min/m2; p=0.045) and adenosine-induced HR increase (mean : 80.5/min vs 89.7/min ; p=0.03), compared to the pre-menopausal women. On the contrary, the two male groups of the same age range and numbers with the women groups showed no significant difference in any myocardial parameters. These results suggest that menopause may be correlated with reduced increase in cardiac index and HR increase after adenosine-stress

  11. Comparison of myocardial function between post-menopausal and pre-menopausal women: evaluation by gated myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, K. H.; Choa, Won Sick; Yoon, Min Ki [Gachon Medical School, Gil Hospital, Incheon (Korea, Republic of)

    2005-07-01

    In addition to inhibiting coronary atherosclerosis, estrogen is expected to have protective effects on cardiac myocytes. We investigated the difference in myocardial functional parameters evaluated by gated myocardial SPECT after adenosine-stress between post-menopausal and pre-menopausal healthy women. This study included 22 healthy post-menopausal women (mean age: 53.0 yr) and 20 pre-menopausal women (mean age: 43.0 yr) who performed Tc-99m tetrofosmin gated myocardial SPECT after adenosine-stress. Measured hemodynamic parameters, EDV, ESV, stroke volume, EF, cardiac output and cardiac index were compared between the two groups. For comparison, similar-aged two male groups with matched numbers were also studied. There was no significant difference in hemodynamic parameters. EDV, ESV, stroke volume, EF, or cardiac output between the post-menopausal and pre-menopausal women. However, post-menopausal women have a smaller cardiac index (mean: 1.95 L/min/m2 vs 2.20 L/min/m2; p=0.045) and adenosine-induced HR increase (mean : 80.5/min vs 89.7/min ; p=0.03), compared to the pre-menopausal women. On the contrary, the two male groups of the same age range and numbers with the women groups showed no significant difference in any myocardial parameters. These results suggest that menopause may be correlated with reduced increase in cardiac index and HR increase after adenosine-stress.

  12. Comparison of multi-slice CT (MSCT) and TI-201 myocardial SPECT in detection of coronary artery disease: relation to coronary arteriography

    Energy Technology Data Exchange (ETDEWEB)

    Pai, M. S.; Kim, Y. K.; Shim, S. S. [College of Medicine, Univ. of Ewha Womens, Seoul (Korea, Republic of)

    2003-07-01

    To evaluate the diagnostic potentials of MSCT and TI-201 SPECT in the assessment of coronary artery disease. Twenty-four patients (15 men, 9 women, 42-79 years) with clinically suspected coronary artery disease were studied by TI-201 myocardial SPECT and MSCT. MSCT data were obtained with 12 x 0.75 mm, 420ms rotation, multi-slice CT scanner (SOMATOM Sensation, Siemens) using non-ionic contrast, 80ml, 4ml/sec. Multiplanar reconstruction techniques were used for evaluation of coronary arteries. TI-201 myocardial SPECT were performed at stress with adenosine and at rest. Data from MSCT and TI-201 SPECT were compared territory by territory (divided into two segments; LAD and RCA/LCx) and related to coronary arteriography, in which more than 60% stenoses are regarded as significant. MSCT and TI-201 SPECT showed agreement in 37 out of 48 segments (77.1%). Out of 11 disagreed segments (22.9), TI-201 SPECT was superior in 6 segments and MSCT was superior in 5 segments. Sensitivities and specificities of MSCT and TI-201 SPECT by coronary arteriography are 81.8%, 69.2% and 86.3%, 76.9%, respectively. Agreed 4 segments between MSCT and TI-201 SPECT exhibited results that differ from the results of coronary arteriography. Myocardial bridge in two cases were detected as significant stenoses by MSCT but showed normal perfusion in TI-201 SPECT. Agreement between MSCT and TI-201 SPECT in the assessment of coronary artery disease was good but TI-201 SPECT has higher sensitivity and specificity for the detection of jeopardized myocardium than MSCT. MSCT and TI-201 SPECT provide complementary information in the assessment of coronary artery disease and could help reduce probable mistake in the interpretation of hemo dynamically insignificant lesion in coronary arteriography.

  13. Dynamic molecular imaging of cardiac innervation using a dual head pinhole SPECT system

    International Nuclear Information System (INIS)

    Hu, Jicun; Boutchko, Rostyslav; Sitek, Arkadiusz; Reutter, BryanW.; Huesman, Ronald H.; Gullberg, Grant T.

    2008-01-01

    Typically 123I-MIBG is used for the study of innervation and function of the sympathetic nervous system in heart failure. The protocol involves two studies: first a planar or SPECT scan is performed to measure initial uptake of the tracer, followed some 3-4 hours later by another study measuring the wash-out of the tracer from the heart. A fast wash-out is indicative of a compromised heart. In this work, a dual head pinhole SPECT system was used for imaging the distribution and kinetics of 123I-MIBG in the myocardium of spontaneous hypertensive rats (SHR) and normotensive Wistar Kyoto (WKY) rats. The system geometry was calibrated based on a nonlinear point projection fitting method using a three-point source phantom. The angle variation effect of the parameters was modeled with a sinusoidal function. A dynamic acquisition was performed by injecting 123I-MIBG into rats immediately after starting the data acquisition. The detectors rotated continuously performing a 360o data acquisition every 90 seconds. We applied the factor analysis (FA)method and region of interest (ROI) sampling method to obtain time activity curves (TACs)in the blood pool and myocardium and then applied two-compartment modeling to estimate the kinetic parameters. Since the initial injection bolus is too fast for obtaining a consistent tomographic data set in the first few minutes of the study, we applied the FA method directly to projections during the first rotation. Then the time active curves for blood and myocardial tissue were obtained from ROI sampling. The method was applied to determine if there were differences in the kinetics between SHR and WKY rats and requires less time by replacing the delayed scan at 3-4 hours after injection with a dynamic acquisition over 90 to 120 minutes. The results of a faster washout and a smaller distribution volume of 123I-MIBG near the end of life in the SHR model of hypertrophic cardiomyopthy may be indicative of a failing heart in late stages of heart

  14. Detecting early cardiac dysfunction with radionuclide cardiac blood-pool imaging

    International Nuclear Information System (INIS)

    Wu Kegui; Chen Daguang; Lin Haoxue

    1992-01-01

    Cardiac function was measured by radionuclide cardiac blood-pool imaging in 15 normal persons, 19 cases of hypertension, 32 cases of coronary heart disease, 35 cases of coronary heart disease combined with hypertension and 44 cases of myocardial infarction. Significant differences have been found in indices of cardiac function between normal subjects and patients with coronary heart disease and coronary heart disease combined with hypertension, even though the patients were without any clinical sin of cardiac failure. Lowered regional EF and decreased ventricular was motion were found in 38.8% of patients, while 65.7%of patients revealed marked abnormality in MFR. The results indicate that latent cardiac dysfunction is common in patients with coronary heart disease. The earliest change is diastolic function abnormalities

  15. Study on localization diagnosis with SPECT rCBF image in childhood epilepsy: in comparison with EEG and MRI findings

    International Nuclear Information System (INIS)

    Wu Meiqian; Tang Jihong; Wu Jinchang; Shi Yizhen

    1999-01-01

    Objective: To evaluate the diagnostic value of SPECT rCBF imaging in localization of childhood epileptic foci. Methods: rCBF imaging was performed in 74 epileptic patients not in seizure and 10 epileptic patients right in seizure. EEG was performed in 84, MRI in 67 of the subjects mentioned above. All the results of three modalities were compared with each other. Results: The highest positive rate (82.14%) was found in SPECT rCBF imaging, the positive rate in EEG or MRI was 71.43 or 47.76%. The epileptic foci localized by EEG (60 abnormalities) and by MRI (32 abnormalities) were 70.59% or 58.82% in concordance with those by SPECT, respectively. Conclusions: SPECT rCBF imaging is a sensitive and effective method for epileptic foci localization. It may have some advantages over EEG and MRI in detecting and localizing epileptic foci. However, abnormal SPECT areas may cover some abnormalities which do not belong to epileptic category. A combination of these three methods (SPECT, EEG and MRI) will improve the positive rate and accuracy for localizing

  16. SPECT/CT and pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, Jann [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); The Faroese National Hospital, Department of Medicine, Torshavn (Faroe Islands); Gutte, Henrik [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Herlev Hospital, Copenhagen University Hospital, Department of Radiology, Copenhagen (Denmark); University of Copenhagen, Cluster for Molecular Imaging, Faculty of Health Sciences, Copenhagen (Denmark)

    2014-05-15

    Acute pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/P) scintigraphy or pulmonary CT angiography (CTPA). In recent years both techniques have improved. Many nuclear medicine centres have adopted the single photon emission CT (SPECT) technique as opposed to the planar technique for diagnosing PE. SPECT has been shown to have fewer indeterminate results and a higher diagnostic value. The latest improvement is the combination of a low-dose CT scan with a V/P SPECT scan in a hybrid tomograph. In a study comparing CTPA, planar scintigraphy and SPECT alone, SPECT/CT had the best diagnostic accuracy for PE. In addition, recent developments in the CTPA technique have made it possible to image the pulmonary arteries of the lungs in one breath-hold. This development is based on the change from a single-detector to multidetector CT technology with an increase in volume coverage per rotation and faster rotation. Furthermore, the dual energy CT technique is a promising modality that can provide functional imaging in combination with anatomical information. Newer high-end CT scanners and SPECT systems are able to visualize smaller subsegmental emboli. However, consensus is lacking regarding the clinical impact and treatment. In the present review, SPECT and SPECT in combination with low-dose CT, CTPA and dual energy CT are discussed in the context of diagnosing PE. (orig.)

  17. Neuropsychiatry: PET and SPECT

    International Nuclear Information System (INIS)

    Quintana F, Juan Carlos

    2002-01-01

    Functional brain imaging with PET and SPECT have a definitive and well established role in the investigation of a variety of conditions such as dementia, epilepsy and drug addiction. With these methods it is possible to detect early rCBF (regional Cerebral Blood Flow) changes seen in dementia (even before clinical symptoms) and differentiate Alzheimer's disease from other dementias by means of the rCBF pattern change. 18-F-FDG PET imaging is a useful tool in partial epilepsy because both rCBF and brain metabolism are compromised at the epileptogenic focus. During the seizure, rCBF dramatically increases locally. Using SPECT it is possible to locate such foci with 97% accuracy. In drug addiction, particularly with cocaine, functional imaging has proven to be very sensitive to detect brain flow and metabolism derangement early in the course of this condition. These findings are important in many ways: prognostic value, they are used as a powerful reinforcement tool and to monitor functional recovery with rehabilitation. There are many other conditions in which functional brain imaging is of importance such as acute stroke treatment assessment, trauma rehabilitation and in psychiatric and abnormal movement diseases specially with the development of receptor imaging (au)

  18. Dopamine transporter imaging with [I-123]IPT SPECT in normal controls and Parkinson's patients: Feasibility study of a simplified SPECT scan protocol

    International Nuclear Information System (INIS)

    Kim, H. J.; Bong, J. K.; Nam, K. P.; Yang, S. O.; Moon, D. H.; Ryu, J. S.; Lee, H. K.

    1997-01-01

    [I-123]IPT has been used to measure changes in dopamine trasnporters with Parkinson's patients (PP). However, 2 hrs of imaging time without movement of patient's head partially limits its widespread use in routine clinical SPECT protocol. The purpose of this study was to evaluate the feasibility of a simplified IPT SPECT scan protocol using three 10 min scan data obtained at 0-10, 55-65, and 110-120 min postinjection and compared to current protocol using 23 scans obtained from O-120 min to quantify dopamine transporter binding in normal controls (NC) and PP. IPT labeled with 6.74±0.88mCi of I-123 was intravenously injected into 12 NC (age: 41±9) and 22 PP (age : 55±8) and the 5 min dynamic SPECT data were acquired for 2 hrs with Trionix triple-headed SPECT camera. SPECT images were reconstructed and attenuation corrected. [I-123] IPT quickly penetratd the blood-brain barrier and began to Ioacalize higher concentrations at the basal ganglia at 20 min after injection. The transporter parameter was measured using a variation of graphical analysis (VGA) and area ratio method (ARM) that derive the distribution volume ratios (R v =V 3 /V 2 for VGA, R A =V 3 /V 2 for ARM ) from multiple scan data without blood data, R v ' and R A ' measured from three 10 min scan data and compared with R v and R A measured from 23 scans for both NC and PP, (R v ', R v ') or NC and PP were (1.83±0.29, 2.21±0.34) and (0.63±0.34, 0.77±0.31), respectively. (R v ', R A ) for NC and PP were (1.11±0.22, 1.62±0.28) and (0.43±0.21, 0.65±0.24), respectively, Both (R v ', R v ) and (R A ', R A ) for NC were clearly separated from those for PP. R' v and R' A underestimated R v and R A by 18.4% and 33.5%, respectively, but R v ' and R A ' showed excellent correlations with R v (r=0.95) and R A (r=0.97), respectively. The results indicate that the three 10 min scan protocol may be feasible and allows us to differentiate dopamine transporter parameters in PP from those in NC

  19. Comparison between unstable angina pectoris and stable effort angina pectoris by using 123I-BMIPP and 201Tl myocardial SPECT

    International Nuclear Information System (INIS)

    Hisatake, Shinji; Yamashina, Shohei; Yamazaki, Junichi

    2004-01-01

    We performed BMIPP myocardial SPECT and Tl myocardial SPECT in patients with unstable angina (UAP) and stable effort angina (SAP), and compared the results for the two groups. Our subjects were 30 patients with the UAP and 25 patients with the SAP. The early and delayed images of the BMIPP were obtained with patients at rest. The early image of the Tl alone was obtained with patients at rest. We calculated severity score (SS) using the polar map based on SPECT short-axis image on the both myocardial SPECT. And, we calculated % uptake of the responsible coronary lesion and regional washout rate (WR) on myocardial SPECT with BMIPP. On coronary angiogram, no difference in % diameter stenosis was seen between the two groups. On myocardial SPECT with Tl, no difference in the SS was seen between the two groups. However, on myocardial SPECT with BMIPP, the SS was significantly higher score in the UAP group than in the SAP group. And, on myocardial SPECT with BMIPP, the % uptake and the WR were significant lower values in the UAP group than in the SAP group. Even if the two groups have almost the same level of myocardial perfusion disorder, the UAP group may have severer myocardial fatty-acid metabolic disorder than the SAP group, because the defects in BMIPP were significantly severer in the UAP group. (author)

  20. Longitudinal evaluation of early dementia of Alzheimer type using brain perfusion SPECT

    International Nuclear Information System (INIS)

    Kogure, Daiji; Matsuda, Hiroshi; Ohnishi, Takashi; Kunihiro, Toshiyuki; Uno, Masataka; Asada, Takashi; Takasaki, Masaru

    1999-01-01

    Regional cerebral blood flow (rCBF) measurements using a Patlak plot method of 99m Tc-ECD were performed in early dementia of Alzheimer type (DAT) with both HDS-R and MMSE of over 20 to investigate initial abnormality and longitudinal changes of rCBF. A fusion technique of MRI and SPECT images was developed for MRI-guided analysis of regions of interest in hippocampal areas and statistical parametric mapping (SPM) was used for automated and objective approach to analysis of SPECT image data. Seventeen patients with clinically diagnosed early DAT and age-matched 32 normal control subjects were studied. At the first SPECT studies, the mean cerebral blood flow (mCBF) of 38.6±4.7 ml/100 g/min (mean±SD) for early DAT did not show significant reduction as compared with the normal control value of 42.0±3.8, whereas the rCBF values in the bilateral hippocampi (right; 26.8±4.7, left; 26.7±5.2) showed significant reduction (p<0.05) as compared with the normal control values (right; 38.3±4.2, left; 38.4±3.8). The SPM analysis (voxel height; p<0.001, Bonferroni correction; p<0.05) of the first SPECT images revealed significant selective decrease of relative rCBF in the bilateral posterior cingulate gyri. At the second SPECT studies after 1.4 year on the average from the first studies, mCBF for early DAT showed a slight decrease by 1.7±3.8 ml/100 g/min/year. Bilateral hippocampi showed a greater decrease with slight left side dominance by 3.8±3.3 on the right and 4.4±3.2 on the left side. The SPM analysis demonstrated significant decrease of relative rCBF in the basal forebrain area, the left hippocampus, the left amygdala, and the left parahippocampal area. These results suggest that the MRI-guided ROI analysis of rCBF values in the hippocampus and the SPM analysis of SPECT images are quite useful for early diagnosis and follow-up of DAT. (author)

  1. Half a decade of mini-pool nucleic acid testing: Cost-effective way for improving blood safety in India

    Directory of Open Access Journals (Sweden)

    Shivaram Chandrashekar

    2014-01-01

    Full Text Available Background and Objectives: It is well established that Nucleic acid testing (NAT reduces window phase of transfusion transmissible infections (TTI and helps improve blood safety. NAT testing can be done individually or in pools. The objectives of this study were to determine the utility, feasibility and cost effectiveness of an in-house minipool-NAT(MP-NAT. Materials and Methods: Blood donors were screened by history, tested by ELISA and sero-negative samples were subjected to an in-house NAT by using reverse transcriptase-polymerase chain reaction (RT-PCR. Testing was done in mini-pools of size eight (8. Positive pools were repeated with individual samples. Results: During the study period of Oct 2005-Sept 2010 (5 years all blood donors (n=53729 were screened by ELISA. Of which 469 (0.87% were positive for HIV-1, HBV or HCV. Sero-negative samples (n=53260 were screened by in-house MP-NAT. HIV-NAT yield was 1/53260 (n=1 and HBV NAT yield (n=2 was 1/26630. Conclusion: NAT yield was lower than other India studies possibly due to the lower sero-reactivity amongst our donors. Nevertheless it intercepted 9 lives including the components prepared. The in-house assay met our objective of improving blood safety at nominal cost and showed that it is feasible to set up small molecular biology units in medium-large sized blood banks and deliver blood within 24-48 hours. The utility of NAT (NAT yield will vary based on the donor population, the type of serological test used, the nature of kit employed and the sensitivity of NAT test used. The limitations of our in-house MP-NAT consisted of stringent sample preparation requirements, with labor and time involved. The benefits of our MP-NAT were that it acted as a second level of check for ELISA tests, was relatively inexpensive compared to ID-NAT and did not need sophisticated equipment.

  2. Automated voxel-based analysis of brain perfusion SPECT for vasospasm after subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Iwabuchi, S.; Yokouchi, T.; Hayashi, M.; Kimura, H.; Tomiyama, A.; Hirata, Y.; Saito, N.; Harashina, J.; Nakayama, H.; Sato, K.; Aoki, K.; Samejima, H.; Ueda, M.; Terada, H.; Hamazaki, K.

    2008-01-01

    We evaluated regional cerebral blood flow (rCBF) during vasospasm after subarachnoid haemorrhage ISAH) using automated voxel-based analysis of brain perfusion single-photon emission computed tomography (SPELT). Brain perfusion SPECT was performed 7 to 10 days after onset of SAH. Automated voxel-based analysis of SPECT used a Z-score map that was calculated by comparing the patients data with a control database. In cases where computed tomography (CT) scans detected an ischemic region due to vasospasm, automated voxel-based analysis of brain perfusion SPECT revealed dramatically reduced rCBF (Z-score ≤ -4). No patients with mildly or moderately diminished rCBF (Z-score > -3) progressed to cerebral infarction. Some patients with a Z-score < -4 did not progress to cerebral infarction after active treatment with a angioplasty. Three-dimensional images provided detailed anatomical information and helped us to distinguish surgical sequelae from vasospasm. In conclusion, automated voxel-based analysis of brain perfusion SPECT using a Z-score map is helpful in evaluating decreased rCBF due to vasospasm. (author)

  3. Effect of pregnancy on regional cerebral blood flow

    International Nuclear Information System (INIS)

    Nagamachi, Shigeki; Hoshi, Hiroaki; Jinnouchi, Seishi; Ohnishi, Takashi; Futami, Shigemi; Watanabe, Katsushi; Ikeda, Tomoaki; Mori, Norimasa

    1993-01-01

    Regional cerebral blood flow (r-CBF) of 10 pregnant women were quantified by 133 Xe SPECT study with inhalation method before and after artificial abortion. During pregnancy, value of r-CBF in each region except occipital lobe was significantly higher than that of the post abortion. Arterial blood gas was analyzed after SPECT procedure. P co2 concentration increased significantly after artificial abortion. Although its mechanism is unknown, our preliminary work demonstrates that r-CBF increased by pregnancy. (author)

  4. The usefulness of CBF brain SPECT in forensic medicine: the civil law codes cases. A description of four cases

    International Nuclear Information System (INIS)

    Piskunowicz, M.; Lass, P.; Bandurski, T.; Krzyzanowski, M.

    2003-01-01

    The aim of this report was to assess the usefulness of cerebral blood flow (CBF) scanning utilising the SPECT technique in forensic medicine cases in the area of civil law cases. CBF SPECT scanning was performed in four patients utilising 99m Tc-ECD and a triple-head gammacamera. In the analysis both the asymmetry index and cerebellar normalisation were applied. Reference values were obtained by studying 30 healthy volunteers. In those cases CBF SPECT scanning played an important role in forensic argument. It influenced the sentence and the amount of financial compensation. CBF SPECT scanning may provide valuable information in forensic medicine argument in civil law cases, but only when taken together with psychometric tests and other neuroimaging methods (CT, MRI). The value of CBF SPECT scanning alone may be limited in judicial proceedings. (author)

  5. Clinical experience with Tc-99m HM-PAO high resolution SPECT of the brain in patients with cerebrovascular accidents

    International Nuclear Information System (INIS)

    Roo, M. de; Mortelmans, L.; Devos, P.; Verbruggen, A.; Wilms, G.; Carton, H.; Wils, V.; Bergh, R. van den

    1989-01-01

    In order to evaluate the diagnostic contribution of brain SPECT imaging with 99m Tc-HMPAO in cerebrovascular disease, we examined 92 stroke cases (144 lesions), 2 hematoma cases and 30 cases with transient neurologic symptoms. Abnormal tracer distribution is visible as zones of either hypoactivity or hyperactivity (border zone hyperemia or luxury perfusion). Remote vascularization changes could also be found (crossed cerebellar diaschisis or ipsilateral cortical perfusion reduction in thalamic or capsula interna lesions). Both X-ray CT and blood flow SPECT have comparable sensitivity in the exploaration of cerebral infarction, with detection in, respectively, 89,5% and 87,5% of the lesions. False negative scintitomographic images are frequently recorded in small lacunar infarcts within the basal ganglia and white matter (capsula interna). Some early infarcts and asymmetry of brain perfusion in patients with transient neurologic symptoms are frequently not detected by CT. An additional advantage of blood flow SPECT is its ability to visualize remote blood flow changes and the changing pattern of vascularization of ischemic lesions and their surrounding areas including hyperemia. (orig.)

  6. Clinical experience with Tc-99m HM-PAO high resolution SPECT of the brain in patients with cerebrovascular accidents

    Energy Technology Data Exchange (ETDEWEB)

    Roo, M. de; Mortelmans, L.; Devos, P.; Verbruggen, A.; Wilms, G.; Carton, H.; Wils, V.; Bergh, R. van den

    1989-01-01

    In order to evaluate the diagnostic contribution of brain SPECT imaging with /sup 99m/Tc-HMPAO in cerebrovascular disease, we examined 92 stroke cases (144 lesions), 2 hematoma cases and 30 cases with transient neurologic symptoms. Abnormal tracer distribution is visible as zones of either hypoactivity or hyperactivity (border zone hyperemia or luxury perfusion). Remote vascularization changes could also be found (crossed cerebellar diaschisis or ipsilateral cortical perfusion reduction in thalamic or capsula interna lesions). Both X-ray CT and blood flow SPECT have comparable sensitivity in the exploaration of cerebral infarction, with detection in, respectively, 89,5% and 87,5% of the lesions. False negative scintitomographic images are frequently recorded in small lacunar infarcts within the basal ganglia and white matter (capsula interna). Some early infarcts and asymmetry of brain perfusion in patients with transient neurologic symptoms are frequently not detected by CT. An additional advantage of blood flow SPECT is its ability to visualize remote blood flow changes and the changing pattern of vascularization of ischemic lesions and their surrounding areas including hyperemia.

  7. Reduced contralateral hemispheric flow measured by SPECT in cerebellar lesions

    DEFF Research Database (Denmark)

    Sönmezoğlu, K; Sperling, B; Henriksen, T

    1993-01-01

    Four patients with clinical signs of cerebellar stroke were studied twice by SPECT using 99mTc-HMPAO as a tracer for cerebral blood flow (CBF). When first scanned 6 to 22 days after onset, all had a region of very low CBF in the symptomatic cerebellar hemisphere, and a mild to moderate CBF reduct...

  8. I-123 IMP SPECT in Parkinson's disease; In relation to the presence or absence of dementia

    Energy Technology Data Exchange (ETDEWEB)

    Kawabata, Keita; Tachibana, Kyudai; Sugita, Minoru [Hyogo Medical Coll., Nishinomiya (Japan)

    1990-12-01

    To examine semiquantitatively regional cerebral blood flow, SPECT with N-isopropyl-p-(I-123)iodoamphetamine (I-123 IMP) was undertaken in 17 patients with Parkinson's disease. Seven patients with Alzheimer's disease and 9 senile control subjects were also imaged for comparison. Both the Parkinson's disease group and the Alzheimer's disease group had a decreased uptake of I-123 IMP in the frontal lobe, in comparison with the control group. A remarkably decreased uptake was seen in the lateral and parietal lobes in the group of Parkinson's disease associated with dementia, as well as in the Alzheimer's disease group. A significantly decreased uptake was observed in the frontal lobe, lateral lobe, thalamus, and basal ganglia in the Parkinson's disease group, irrespective of the presence or absence of dementia. For Parkinson's disease associated with dementia, there was much more significant decrease in I-123 IMP uptake. The pattern of regional cerebral blood flow in the Alzheimer's disease group was analogous to that in the Parkinson's disease group associated with dementia. This supports the hypothesis that Alzheimer's disease may be somewhat involved in the occurrence of dementia for Parkinson's disease. (N.K.).

  9. Partial volume correction in SPECT reconstruction with OSEM

    Energy Technology Data Exchange (ETDEWEB)

    Erlandsson, Kjell, E-mail: k.erlandsson@ucl.ac.uk [Institute of Nuclear Medicine, University College London and University College London Hospital, London NW1 2BU (United Kingdom); Thomas, Ben; Dickson, John; Hutton, Brian F. [Institute of Nuclear Medicine, University College London and University College London Hospital, London NW1 2BU (United Kingdom)

    2011-08-21

    SPECT images suffer from poor spatial resolution, which leads to partial volume effects due to cross-talk between different anatomical regions. By utilising high-resolution structural images (CT or MRI) it is possible to compensate for these effects. Traditional partial volume correction (PVC) methods suffer from various limitations, such as correcting a single region only, returning only regional mean values, or assuming a stationary point spread function (PSF). We recently presented a novel method in which PVC was combined with the reconstruction process in order to take into account the distance dependent PSF in SPECT, which was based on filtered backprojection (FBP) reconstruction. We now present a new method based on the iterative OSEM algorithm, which has advantageous noise properties compared to FBP. We have applied this method to a series of 10 brain SPECT studies performed on healthy volunteers using the DATSCAN tracer. T1-weighted MRI images were co-registered to the SPECT data and segmented into 33 anatomical regions. The SPECT data were reconstructed using OSEM, and PVC was applied in the projection domain at each iteration. The correction factors were calculated by forward projection of a piece-wise constant image, generated from the segmented MRI. Images were also reconstructed using FBP and standard OSEM with and without resolution recovery (RR) for comparison. The images were evaluated in terms of striatal contrast and regional variability (CoV). The mean striatal contrast obtained with OSEM, OSEM-RR and OSEM-PVC relative to FBP were 1.04, 1.42 and 1.53, respectively, and the mean striatal CoV values are 1.05, 1.53, 1.07. Both OSEM-RR and OSEM-PVC results in images with significantly higher contrast as compared to FBP or OSEM, but OSEM-PVC avoids the increased regional variability of OSEM-RR due to improved structural definition.

  10. Clinical applications of SPECT-CT

    Energy Technology Data Exchange (ETDEWEB)

    Ahmadzadehfar, Hojjat; Biersack, Hans-Juergen (eds.) [University Hospital Bonn (Germany). Dept. of Nuclear Medicine

    2014-06-01

    Covers the full spectrum of clinical applications of SPECT/CT in diagnosis of benign and malignant diseases. Includes chapters on the use of SPECT/CT for dosimetry and for therapy planning. Completely up to date. Many helpful illustrations. SPECT/CT cameras have considerably improved diagnostic accuracy in recent years. Such cameras allow direct correlation of anatomic and functional information, resulting in better localization and definition of scintigraphic findings. In addition to this anatomic referencing, CT coregistration provides superior quantification of radiotracer uptake based on the attenuation correction capabilities of CT. Useful applications of SPECT/CT have been identified not only in oncology but also in other specialties such as orthopedics and cardiology. This book covers the full spectrum of clinical applications of SPECT/CT in diagnosis and therapy planning of benign and malignant diseases. Opening chapters discuss the technology and physics of SPECT/CT and its use for dosimetry. The role of SPECT/CT in the imaging of a range of pathologic conditions is then addressed in detail. Applications covered include, among others, imaging of the thyroid, bone, and lungs, imaging of neuroendocrine tumors, cardiac scintigraphy, and sentinel node scintigraphy. Individual chapters are also devoted to therapy planning in selective internal radiation therapy of liver tumors and bremsstrahlung SPECT/CT. Readers will find this book to be an essential and up-to-date source of information on this invaluable hybrid imaging technique.

  11. Contribution of ictal- and interictal brain SPECT to the diagnostic work-up of epileptic patients

    International Nuclear Information System (INIS)

    Dondi, M.; Salgarello, M.; Zoboli, S.; Cidda, C.; Nanni, C.; Rubboli, G.; Meletti, S.; Volpi, L.; Tassinari, C.A.

    2002-01-01

    Aim of the study: We aimed at assessing the contribution of brain SPECT to the diagnostic work-up of patients admitted to the Intensive Epilepsy Monitoring Unit (IEMU) by evaluating concordance of SPECT results with clinical diagnosis (DX) at IEMU admittance (Adm-DX) and at hospital discharge (Disch-DX). Materials and methods: 48 consecutive patients were enrolled in this study and submitted to both ictal and inter-ictal brain SPECT, carried out by means of a three-head system. Before ictal studies, patients were video-EEG monitored in the IEMU. 740 MBq of Tc99m ECD were injected during seizures and imaging performed within 45-60 minutes. For interictal studies, injection was given after at least a 24-hours seizure-free interval. Slices were reconstructed along the orbito-meatal line as well as along the temporal cut. Possible epileptic foci were identified by visual comparison of ictal and interictal studies. Clinical data: Out of the 48 cases, 27 were diagnosed as temporal lobe epilepsies (TLE). Of these, 15 had an Adm-DX of lateralization, whereas 12 were not lateralized according to standardized clinical and EEG criteria. Frontal lobe epilepsy (FLE) was diagnosed in 11 patients, another group of 3 was classified as cryptogenetic (CRYP), while the remaining 7 cases did not fall into any of the previous groups (OTH). SPECT results: in TLE, ictal/interictal SPECT results were congruent with Adm-Dx in 13/27 cases (48%) whereas congruence was found with 25 out of 27 (92%) of Disch-DX. In FLE, concordance between SPECT and clinical diagnosis remained unchanged (9/11 in comparison to either Adm-DX or Disch-DX). CRYPT patients had no lateralization at Adm-DX, while Dis-DX was concordant with SPECT in 2/3 cases. The group labeled as OTH showed concordance SPECT with Adm-DX in 0/7 cases, as opposed to 5/7 of Disch-DX. On the whole, SPECT results were concordant with Adm-DX in 34/48 cases (71%) but concordance was much higher with Dis-DX (41/48; 85%). Conclusions: Brain

  12. Clinical evaluation of Parkinson's disease using 123I-IMP SPECT

    International Nuclear Information System (INIS)

    Hayashi, Hiroko; Odano, Ikuo; Nishihara, Mamiko; Higuchi, Shouichi; Sakai, Kunio; Ishikawa, Atsushi.

    1989-01-01

    N-isopropyl-p[ 123 I]iodoamphetamine ( 123 I-IMP) SPECT and regional cerebral blood flow (rCBF) studies were performed in 20 patients with Parkinson's disease (PD) and 8 normal subjects. RCBF was measured by the arterial blood sampling method which used the microsphere model. We analized seven factors which might be related to the rCBF in PD, i.e., age, stage, duration of the disease, cerebral atrophy, severity of dementia, laterality of symptoms and motor disability score (MDS; the degree of akinesia, rigidity, tremor, gait disturbance, freezing and pulsion sign). Compared with normal subjects, global CBF (supratentorial mean rCBF) was reduced by 21.8% in PD. In particular, rCBF in the basal ganglia and that of frontal cortex were reduced by 25.3% and 24.8%, respectively. Distribution patterns of rCBF in PD were almost as same as those in normals except for cerebellum. The reduction of both rCBFs in the basal ganglia and parietal cortex significantly correlated with MDS (p 123 I-IMP SPECT study is a useful method for clinical evaluation of PD. (author)

  13. Recovered neuronal viability revealed by Iodine-123-iomazenil SPECT following traumatic brain injury.

    Science.gov (United States)

    Koizumi, Hiroyasu; Fujisawa, Hirosuke; Kurokawa, Tetsu; Suehiro, Eiichi; Iwanaga, Hideyuki; Nakagawara, Jyoji; Suzuki, Michiyasu

    2010-10-01

    We evaluated cortical damages following traumatic brain injury (TBI) in the acute phase with [(123)I] iomazenil (IMZ) single photon emission computed tomography (SPECT). In all, 12 patients with cerebral contusion following TBI were recruited. All patients underwent IMZ SPECT within 1 week after TBI. To investigate the changes in distribution of IMZ in the cortex in the chronic phase, after conventional treatment, patients underwent IMZ SPECT again. A decrease in the accumulation of radioligand for the central benzodiazepine receptor in the cortex corresponding to the contusion revealed with computed tomography (CT) scans and magnetic resonance imaging (MRI) were shown on IMZ SPECT in the acute phase in all patients. In 9 of 12 patients (75%), images of IMZ SPECT obtained in the chronic phase of TBI showed that areas with a decreased distribution of IMZ were remarkably reduced in comparison with those obtained in the acute phase. Both CT scans and MRI showed a normal appearance of the cortex morphologically, where the binding potential of IMZ recovered in the chronic phase. Reduced binding potential of radioligand for the central benzodiazepine receptor is considered to be an irreversible reaction; however, in this study, IMZ accumulation in the cortex following TBI was recovered in the chronic phase in several patients. [(123)I] iomazenil SPECT may have a potential to disclose a reversible vulnerability of neurons following TBI.

  14. The EEG, CT and Tc-99m HMPAO SPECT study in patients with epilepsy

    International Nuclear Information System (INIS)

    Tovuudorj, A.; Tsagaankhuu, G.; Onkhuudai, P.; Tsevelmaa, L.; Sereegotov, E.; Enkhtuya, B.

    2007-01-01

    Full text: We have put an objective of studying the EEG and neuroimaging diagnostic indexes (CT, SPECT) in patients with partial seizures during interictal period. Methods: In our study a total of 35 cases were included (20 male and 15 females). In EEG studies we used the diagnostics methodology elaborated by L.R.Zenkov (1996) and in SPECT study by Payne JK (1991) and in CT investigation by Chermissan V.M (2001). Results: By EEG study the cases of interictal period of partial seizure were mostly revealed in the form of sharp waves in temporal lobe (47.62.5%). By CT study the 18 (51.4 ± 2.5 %) cases of partial seizure with normal index, 12 (34.3 ± 1.8 %) cases with dilatation of ventricles and 5 (14.3 ± 2.1%) cases of cerebral atrophy. In SPECT investigation we identified 8 (22.81.8%) cases with normal brain blood flow supply and 27 (77.2 2.0%) cases with variable degrees of hypoperfusion (AI) in the temporal lobe was reaching 233.9% (p<0.01). Conclusion: 1. On EEG analysis during interictal period of partial seizures, there were prevailing sharp-waves (47.6 ± 2.5%) at temporal location of a hemispheres. 2. The brain CT investigation during epilepsy mostly revealed the normal indexes 3. By analyzing brain SPECT during the interictal period of seizures, there were prevailing hypoperfusion degrees (AI) of blood flow to reach 23.0 ± 3.9%. (author)

  15. Differentiating Primary CNS Lymphoma from Malignant Glioma using 123I-IMP SPECT and Arterial Spin labeling

    International Nuclear Information System (INIS)

    Ito, Tamio; Sato, Kenichi; Ozaki, Yoshimaru; Asanome, Taku; Nakamura, Hirohiko; Ono, Hidetoshi

    2016-01-01

    Using conventional CT or MRI methods, the differentiation of primary central nervous system lymphoma (PCNSL) and malignant glioma (MG) is difficult because of overlapping imaging characteristics. Pretreatment differentiation between PCNSL and MG is essential for therapeutic decision making because post operative adjuvant therapy is extremely different. We examined the utility of N-isopropyl-p-[ 123 I]iodoamphetamine SPECT (IMP SPECT) and arterial spin labeling (ASL) in differentiating PCNSL from MG. Twenty PCNSL and ten MG patients underwent IMP SPECT and ASL. Early SPECT image (E) was initiated 20 min after intravenous injection of 222 MBq 123 I-IMP, and delayed image (D) and ultrade-layed image (UD) were initiated 3 h and 24 h, respectively, after the injection. SPECT images were visually analyzed with a color-grading scale (low, iso, and high), and the tumor-to-normal activity ratio (T/N) was calculated for all three images. The pulsed ASL was performed using a 3-T system. We set regions of interest in the tumor and symmetrically in the contralateral white matter on the cerebral blood flow (CBF) map and estimated tumor blood flow (TBF)/CBF ratio (TBF/CBF). 1) IMP SPECT: (1) Visual image analysis of PCNSL cases showed high accumulation of 123 I-IMP up-take on D and UD, whereas most MG cases showed low accumulation. (2) T/Ns of PCNSL were significantly higher than those of MG on D and UD (E: 1.13 vs. 0.95, p>0.05; D: 1.23 vs. 0.86, p<0.01; UD: 1.40 vs. 0.86, p<0.01). 2) ASL: TBF/CBFs of MG were higher than those of PCNSL, particularly in glioblastoma patients [1.84 vs. 6.22 (III; 1.51, IV; 8.58)]. IMP SPECT and ASL are helpful tools for differentiating primary CNS lymphoma from MG. Using these examinations, we could perform adjuvant therapy without biopsy in deep-seated tumors. (author)

  16. Brain SPECT in children

    International Nuclear Information System (INIS)

    Guyot, M.; Baulieu, J.L.

    1996-01-01

    Brain SPECT in child involves specific trends regarding the patient cooperation, irradiation, resolution and especially interpretation because of the rapid scintigraphic modifications related to the brain maturation. In a general nuclear medicine department, child brain SPECT represents about 2 % of the activity. The choice indications are the perfusion children: thallium and MIBI in brain tumours, pharmacological and neuropsychological interventions. In the future, brain dedicated detectors and new radiopharmaceuticals will promote the development of brain SPECT in children. (author)

  17. Subendocardial versus transmural ischaemia in myocardial perfusion SPECT--a Monte Carlo study

    DEFF Research Database (Denmark)

    Bartosik, Jolanta; El-Ali, Henrik Hussein; Nilsson, Ulf

    2006-01-01

    Myocardial perfusion imaging with single-photon emission computed tomography (SPECT) is useful for the evaluation of patients with known or suspected coronary artery disease. Parameters of interest are the reduction in the blood perfusion (severity) and the lesion volume (extent). The aim of this...

  18. Brain SPECT in childhood

    International Nuclear Information System (INIS)

    Tranquart, F.; Saliba, E.; Prunier, C.; Baulieu, F.; Besnard, J.C.; Guilloteau, D.; Baulieu, J.L.

    2001-01-01

    The modalities and the indications of perfusion and neurotransmission SPECT in childhood are presented. The perfusion as well as neurotransmission tracers have not yet authorization for use in children; they have to be used by prescription of magistral preparation or in research protocols. The radioprotection rules have to be strictly respected. The most frequent indication of perfusion SPECT is pharmacologically resistant epilepsy; the ictal SPECT before surgery allows the localization of the epileptogenic focus. Other indications are relevant in the prognosis of neonatal anoxia and encephalitis. In psychiatric disorders, especially in autism, the interest is the physiopathological approach of the brain dysfunctions. The neurotransmission SPECT is emerging as a consequence of the development of new radiotracer, as the dopaminergic system ligands. The decrease of the dopamine D2 receptors in the striatum can be imaged and quantified in the neonate. The lesions of dopamine system seem to be a consequence of the neonatal hypoxia-ischemia and it is predictive of motor sequelae. Brain SPECT should become a routine examination in child neurologic and psychiatric disorders. (authors)

  19. Development of a practical image-based scatter correction method for brain perfusion SPECT: comparison with the TEW method

    International Nuclear Information System (INIS)

    Shidahara, Miho; Kato, Takashi; Kawatsu, Shoji; Yoshimura, Kumiko; Ito, Kengo; Watabe, Hiroshi; Kim, Kyeong Min; Iida, Hidehiro; Kato, Rikio

    2005-01-01

    An image-based scatter correction (IBSC) method was developed to convert scatter-uncorrected into scatter-corrected SPECT images. The purpose of this study was to validate this method by means of phantom simulations and human studies with 99m Tc-labeled tracers, based on comparison with the conventional triple energy window (TEW) method. The IBSC method corrects scatter on the reconstructed image I AC μb with Chang's attenuation correction factor. The scatter component image is estimated by convolving I AC μb with a scatter function followed by multiplication with an image-based scatter fraction function. The IBSC method was evaluated with Monte Carlo simulations and 99m Tc-ethyl cysteinate dimer SPECT human brain perfusion studies obtained from five volunteers. The image counts and contrast of the scatter-corrected images obtained by the IBSC and TEW methods were compared. Using data obtained from the simulations, the image counts and contrast of the scatter-corrected images obtained by the IBSC and TEW methods were found to be nearly identical for both gray and white matter. In human brain images, no significant differences in image contrast were observed between the IBSC and TEW methods. The IBSC method is a simple scatter correction technique feasible for use in clinical routine. (orig.)

  20. Development of a practical image-based scatter correction method for brain perfusion SPECT: comparison with the TEW method.

    Science.gov (United States)

    Shidahara, Miho; Watabe, Hiroshi; Kim, Kyeong Min; Kato, Takashi; Kawatsu, Shoji; Kato, Rikio; Yoshimura, Kumiko; Iida, Hidehiro; Ito, Kengo

    2005-10-01

    An image-based scatter correction (IBSC) method was developed to convert scatter-uncorrected into scatter-corrected SPECT images. The purpose of this study was to validate this method by means of phantom simulations and human studies with 99mTc-labeled tracers, based on comparison with the conventional triple energy window (TEW) method. The IBSC method corrects scatter on the reconstructed image I(mub)AC with Chang's attenuation correction factor. The scatter component image is estimated by convolving I(mub)AC with a scatter function followed by multiplication with an image-based scatter fraction function. The IBSC method was evaluated with Monte Carlo simulations and 99mTc-ethyl cysteinate dimer SPECT human brain perfusion studies obtained from five volunteers. The image counts and contrast of the scatter-corrected images obtained by the IBSC and TEW methods were compared. Using data obtained from the simulations, the image counts and contrast of the scatter-corrected images obtained by the IBSC and TEW methods were found to be nearly identical for both gray and white matter. In human brain images, no significant differences in image contrast were observed between the IBSC and TEW methods. The IBSC method is a simple scatter correction technique feasible for use in clinical routine.

  1. 201Thallium SPECT, accuracy in astrocytoma diagnosis and treatment evaluation

    International Nuclear Information System (INIS)

    Kaellen, K.

    1999-10-01

    The aims of the studies included in this thesis were: - to investigate the reliability of 201 Thallium single photon emission computed tomography. Tl SPECT for preoperative diagnosis and histological staging of malignant astrocytomas in comparison with CT; - to develop a method for quantification of cerebral thallium uptake, and to evaluate the quantitative measurement in comparison with CT, for astrocytoma treatment follow-up purposes; - to compare quantitative Tl SPECT and proton magnetic resonance spectroscopy (H-MRS) with conventional MR imaging for astrocytoma monitoring, and to evaluate associations between change of morphological tumour characteristics during treatment and changes of cerebral thallium uptake and metabolic ratios. Results and conclusions: - High TI-index, calculated as a ratio comparing tumour uptake to uptake in the contralateral hemisphere, is an indicator of highly malignant astrocytoma. Differentiation between the high-grade astrocytomas, the low-grade astrocytomas, and infectious lesions is only partial, with an overlap of Tl-indexes between these groups. High-grade astrocytomas that do not show contrast enhancement on CT, and astrocytomas with central necrosis and moderate ring-enhancement, tend to be underestimated when evaluated by Tl-index calculation. Tl SPECT is not a reliable method for non-invasive tumour staging among the group of highly malignant astrocytomas. - Quantification of cerebral TI-uptake, defining the volume of viable tumour tissue, is a new method for astrocytoma chemotherapy monitoring. Results suggest that the method provides prognostic information, and information of treatment efficacy, at an earlier stage than CT. - We did not find a higher accuracy of quantitative Tl SPECT than of MR for monitoring purposes and our results indicated that treatment induced MR changes were interrelated with TI-uptake variations. - Multi-voxel H-MRS was difficult to apply for astrocytoma treatment monitoring, due to the anatomical

  2. Synthesis of fluorine-18 radio-labeled serum albumins for PET blood pool imaging

    International Nuclear Information System (INIS)

    Basuli, Falguni; Li, Changhui; Xu, Biying; Williams, Mark; Wong, Karen; Coble, Vincent L.; Vasalatiy, Olga; Seidel, Jurgen; Green, Michael V.; Griffiths, Gary L.; Choyke, Peter L.; Jagoda, Elaine M.

    2015-01-01

    We sought to develop a practical, reproducible and clinically translatable method of radiolabeling serum albumins with fluorine-18 for use as a PET blood pool imaging agent in animals and man. Fluorine-18 radiolabeled fluoronicotinic acid-2,3,5,6-tetrafluorophenyl ester, [ 18 F]F-Py-TFP was prepared first by the reaction of its quaternary ammonium triflate precursor with [ 18 F]tetrabutylammonium fluoride ([ 18 F]TBAF) according to a previously published method for peptides, with minor modifications. The incubation of [ 18 F]F-Py-TFP with rat serum albumin (RSA) in phosphate buffer (pH 9) for 15 min at 37–40 °C produced fluorine-18-radiolabeled RSA and the product was purified using a mini-PD MiniTrap G-25 column. The overall radiochemical yield of the reaction was 18–35% (n = 30, uncorrected) in a 90-min synthesis. This procedure, repeated with human serum albumin (HSA), yielded similar results. Fluorine-18-radiolabeled RSA demonstrated prolonged blood retention (biological half-life of 4.8 hours) in healthy awake rats. The distribution of major organ radioactivity remained relatively unchanged during the 4 hour observation periods either by direct tissue counting or by dynamic PET whole-body imaging except for a gradual accumulation of labeled metabolic products in the bladder. This manual method for synthesizing radiolabeled serum albumins uses fluorine-18, a widely available PET radionuclide, and natural protein available in both pure and recombinant forms which could be scaled up for widespread clinical applications. These preclinical biodistribution and PET imaging results indicate that [ 18 F]RSA is an effective blood pool imaging agent in rats and might, as [ 18 F]HSA, prove similarly useful as a clinical imaging agent

  3. Synthesis of fluorine-18 radio-labeled serum albumins for PET blood pool imaging.

    Science.gov (United States)

    Basuli, Falguni; Li, Changhui; Xu, Biying; Williams, Mark; Wong, Karen; Coble, Vincent L; Vasalatiy, Olga; Seidel, Jurgen; Green, Michael V; Griffiths, Gary L; Choyke, Peter L; Jagoda, Elaine M

    2015-03-01

    We sought to develop a practical, reproducible and clinically translatable method of radiolabeling serum albumins with fluorine-18 for use as a PET blood pool imaging agent in animals and man. Fluorine-18 radiolabeled fluoronicotinic acid-2,3,5,6-tetrafluorophenyl ester, [(18)F]F-Py-TFP was prepared first by the reaction of its quaternary ammonium triflate precursor with [(18)F]tetrabutylammonium fluoride ([(18)F]TBAF) according to a previously published method for peptides, with minor modifications. The incubation of [(18)F]F-Py-TFP with rat serum albumin (RSA) in phosphate buffer (pH9) for 15 min at 37-40 °C produced fluorine-18-radiolabeled RSA and the product was purified using a mini-PD MiniTrap G-25 column. The overall radiochemical yield of the reaction was 18-35% (n=30, uncorrected) in a 90-min synthesis. This procedure, repeated with human serum albumin (HSA), yielded similar results. Fluorine-18-radiolabeled RSA demonstrated prolonged blood retention (biological half-life of 4.8 hours) in healthy awake rats. The distribution of major organ radioactivity remained relatively unchanged during the 4 hour observation periods either by direct tissue counting or by dynamic PET whole-body imaging except for a gradual accumulation of labeled metabolic products in the bladder. This manual method for synthesizing radiolabeled serum albumins uses fluorine-18, a widely available PET radionuclide, and natural protein available in both pure and recombinant forms which could be scaled up for widespread clinical applications. These preclinical biodistribution and PET imaging results indicate that [(18)F]RSA is an effective blood pool imaging agent in rats and might, as [(18)F]HSA, prove similarly useful as a clinical imaging agent. Published by Elsevier Inc.

  4. Quantification of cerebral blood flow and its clinical usefulness. Application of SPECT to psychiatry

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, Hiroshi; Uema, Takeshi; Kogure, Daisuke; Takano, Harumasa; Terada, Tomo [National Center Hospital for Mental, Nervous and Muscular Disorders, Kodaira, Tokyo (Japan)

    1998-10-01

    Brain perfusion SPECT using {sup 99m}Tc-ethyl-cysteinate dimer ({sup 99m}Tc-ECD) was applied to psychiatric diseases with aid of statistical parametric mapping (SPM) for analysis of data. To evaluate influence of aging on brain perfusion, noninvasive measurements of cerebral blood flow using {sup 99m}Tc-ECD were performed in 53 normal volunteers, aged 18 to 87 years old. Mean cerebral blood flow (mCBF) was 43.9{+-}5.0 ml/100 g/min and showed weak negative correlation with aging (r=-0.451). Perisylvian cerebral cortices and medial frontal areas including anterior cingulate gyri showed greater negative correlation than other areas. These findings suggest the necessity of age-matched control regional CBF (rCBF) data to investigate rCBF abnormality in patients. Four drug-naive schizophrenic patients showed flow decrease in bilateral frontal and superior temporal areas and a left infero-posterior temporal area. Haloperidol administration induced flow decrease in bilateral frontal and left parietal areas, while flow increase in bilateral striatal and right hippocampal areas. Ten aged depressive patients showed flow decrease in bilateral frontal and left temporo-parietal areas. Even after remission patients showed flow decrease in the left frontal area as compared with normal subjects. Remission induced flow increase in the right frontal, right parietal, and right orbitofrontal areas compared with depression. These results suggest that CBF measurements using {sup 99m}Tc-ECD are useful for objective evaluation of regional abnormality in brain function in psychiatric diseases. (author)

  5. Comparison of IMP-SPECT findings to subtest scores of Wechsler intelligence adult Scale-Revised in temporal lobe epilepsy patients

    Energy Technology Data Exchange (ETDEWEB)

    Kan, Rumiko; Uejima, Masahiko; Kaneko, Yuko; Miyamoto, Yuriko; Watabe, Manabu; Takahashi, Ruriko; Niwa, Shin-ichi; Shishido, Fumio [Fukushima Medical Coll. (Japan)

    1998-02-01

    In this study, 40 temporal lobe epilepsy patients were assessed, using the Laterality Index (LI) of ROI values in IMP-SPECT findings, Wechsler adult intelligence Scale-Revised (WAIS-R) and subtest scores. LIs of the frontal, temporal and occipital lobes were calculated as follows: the ROI values on the right side were subtracted from those on the left, and the results was divided by the sum of the ROI values on the right and left sides. The individual subtest scores on WAIS-R were standardized by all evaluation scores in order to exclude the influence of differences in intelligence level as much as possible. The results were as follows: there was a positive correlation (r=0.74, p<0.001) between LI values and the performance in Arithmetic in the left temporal lobe hypoperfusion group. And there was a positive correlation (r=0.50, p<0.02) between LI values and the performance in Vocabulary in the left temporal lobe hypoperfusion group. In the right occipital lobe hypoperfusion group, there was a negative correlation (r=-O.44, pblood flow areas detected by SPECT might influence brain function. (author)

  6. Comparison of IMP-SPECT findings to subtest scores of Wechsler intelligence adult Scale-Revised in temporal lobe epilepsy patients

    International Nuclear Information System (INIS)

    Kan, Rumiko; Uejima, Masahiko; Kaneko, Yuko; Miyamoto, Yuriko; Watabe, Manabu; Takahashi, Ruriko; Niwa, Shin-ichi; Shishido, Fumio

    1998-01-01

    In this study, 40 temporal lobe epilepsy patients were assessed, using the Laterality Index (LI) of ROI values in IMP-SPECT findings, Wechsler adult intelligence Scale-Revised (WAIS-R) and subtest scores. LIs of the frontal, temporal and occipital lobes were calculated as follows: the ROI values on the right side were subtracted from those on the left, and the results was divided by the sum of the ROI values on the right and left sides. The individual subtest scores on WAIS-R were standardized by all evaluation scores in order to exclude the influence of differences in intelligence level as much as possible. The results were as follows: there was a positive correlation (r=0.74, p<0.001) between LI values and the performance in Arithmetic in the left temporal lobe hypoperfusion group. And there was a positive correlation (r=0.50, p<0.02) between LI values and the performance in Vocabulary in the left temporal lobe hypoperfusion group. In the right occipital lobe hypoperfusion group, there was a negative correlation (r=-O.44, p< O.05) between LI values and the performance in Coding. It is suggested that decreased blood flow areas detected by SPECT might influence brain function. (author)

  7. Segmentation and visual analysis of whole-body mouse skeleton microSPECT.

    Directory of Open Access Journals (Sweden)

    Artem Khmelinskii

    Full Text Available Whole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput, multi-modality, postural and positioning variability. The goal of this study was to provide a method to align and compare side-by-side multiple whole-body skeleton SPECT datasets in a common reference, thus eliminating acquisition variability that exists between the subjects in cross-sectional and multi-modal studies. Six whole-body SPECT/CT datasets of BALB/c mice injected with bone targeting tracers (99mTc-methylene diphosphonate ((99mTc-MDP and (99mTc-hydroxymethane diphosphonate ((99mTc-HDP were used to evaluate the proposed method. An articulated version of the MOBY whole-body mouse atlas was used as a common reference. Its individual bones were registered one-by-one to the skeleton extracted from the acquired SPECT data following an anatomical hierarchical tree. Sequential registration was used while constraining the local degrees of freedom (DoFs of each bone in accordance to the type of joint and its range of motion. The Articulated Planar Reformation (APR algorithm was applied to the segmented data for side-by-side change visualization and comparison of data. To quantitatively evaluate the proposed algorithm, bone segmentations of extracted skeletons from the correspondent CT datasets were used. Euclidean point to surface distances between each dataset and the MOBY atlas were calculated. The obtained results indicate that after registration, the mean Euclidean distance decreased from 11.5±12.1 to 2.6±2.1 voxels. The proposed approach yielded satisfactory segmentation results with minimal user intervention. It proved to be robust for "incomplete" data (large chunks of skeleton missing and for an intuitive exploration and comparison of multi-modal SPECT

  8. Preliminary results of SPECT studies with 99mTc-HMPAO in endogenous psychoses

    International Nuclear Information System (INIS)

    Wilhelm, K.R.; Georgi, P.; Schroeder, J.; Henningsen, H.; Sauer, H.

    1989-01-01

    18 psychopharmacologically treated patients (7 schizophrenics, 5 schizoaffectives, 6 depressives) were studied using 99m Tc-HMPAO-SPECT of the brain. The regional cerebral blood flow was measured in three transversal sections (infra-/supraventricular, ventricular) within 6 regions of interest (ROI) respectively (one frontal, one parietal and one occipital in each hemisphere). Corresponding ROIs of the same section in each hemisphere were compared. In the schizophrenics there was a significantly reduced perfusion in the left frontal region of the infraventricular and ventricular section (p 99m Tc-HMPAO-SPECT may be helpful in finding cerebral abnormalities in endogenous psychoses. (orig.) [de

  9. {sup 68}Ga-DOTATATE PET/CT in recurrent medullary thyroid carcinoma: a lesion-by-lesion comparison with {sup 111}In-octreotide SPECT/CT and conventional imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yamaga, Lilian Yuri Itaya; Cunha, Marcelo L.; Campos Neto, Guilherme C.; Garcia, Marcio R.T.; Wagner, Jairo; Funari, Marcelo B.G. [Hospital Israelita Albert Einstein, Imaging Department, Sao Paulo (Brazil); Yang, Ji H.; Camacho, Cleber P. [Universidade Federal de Sao Paulo, Multiple Neoplasia Outpatiet Clinic, Sao Paulo (Brazil)

    2017-09-15

    The aim of this study was to prospectively compare the detection rate of {sup 68}Ga-DOTATATE PET-CT with {sup 111}In-octreotide SPECT-CT and conventional imaging (CI) in medullary thyroid carcinoma (MTC) patients with increased calcitonin (Ctn) levels but negative CI after thyroidectomy. Fifteen patients with raised Ctn levels and/or CI evidence of recurrence underwent {sup 68}Ga-DOTATATE PET-CT, {sup 111}In-octreotide SPECT-CT and CI. Histopathology, CI and biochemical/clinical/imaging follow-up were used as the reference standard. PET/CT, SPECT/CT and CI were compared in a lesion-based and organ-based analysis. PET/CT evidenced recurrence in 14 of 15 patients. There were 13 true positive (TP), 1 true negative (TN), 1 false positive (FP) and no false negative (FN) cases, resulting in a sensitivity and accuracy of 100% and 93%. SPECT/CT was positive in 6 of 15 cases. There were 6 TP, 2 TN, 7 FN and no FP cases, resulting in a sensitivity of 46% and accuracy of 53%. CI procedures detected tumor lesions in 14 of 15 patients. There were 13 TP, 1TN, 1 FP and no FN cases with a sensitivity of 100% and accuracy of 93%. A significantly higher number of lesions was detected by PET/CT (112 lesions, p = 0.005) and CI (109 lesions, p = 0.005) in comparison to SPECT/CT (16 lesions). There was no significant difference between PET/CT and CI for the total number of detected lesions (p = 0.734). PET/CT detected more lesions than SPECT/CT regardless of the organ. PET/CT detected more bone lesions but missed some neck nodal metastases evidenced by CI. The number of lesions per region demonstrated by PET/CT and CI were similar in the other sites. {sup 68}Ga-DOTATATE PET/CT is superior to {sup 111}In-octreotide SPECT/CT for the detection of recurrent MTC demonstrating a significantly higher number of lesions. {sup 68}Ga-DOTATATE PET/CT showed a superior detection rate compared to CI in demonstrating bone metastases. (orig.)

  10. Study on effects of an atypical antipsychotic, risperidone on regional cerebral blood flow with 99mTc-HMPAO SPECT in drug-naive and unmedicated schizophrenic patients

    International Nuclear Information System (INIS)

    Koiwa, Daisuke

    2003-01-01

    To examine the underlying mechanisms of intracerebral or clinical actions of the atypical antipsychotic, risperidone (RIS), the effects of RIS on absolute regional cerebral blood flows (rCBFs) measured with 99mTc-HMPAO SPECT and correlations between the rCBFs and psychotic symptoms assessed with positive and negative syndrome scale (PANSS) were investigated in 10 drug-naive and unmedicated schizophrenic patients with acute hallucinatory and delusional state. Both the SPECT and PANSS were repeated before and after oral 2-week administration of RIS 3 mg/day in all of the 10 patients and after subsequent 2-week administration of RIS 4-6 mg/day in half of the patients. The rCBF values were significantly decreased in the left precentral gyrus alone after the low dose of RIS 3 mg/day in comparison with before the RIS dose. The rCBF values were significantly decreased in the right cingulate, postcentral, inferior parietal gyri and the left inferior temporal gyrus after the high dose of RIS 4-6 mg/day in comparison with before the low dose of RIS 3 mg/day. The psychiatric assessment with PANSS showed an improvement of positive and negative symptoms after the low RIS dose and still more after the high RIS dose. Statistical analyses on relationships between the rCBF values and PANSS scores before and after the low RIS dose showed a positive correlation between the rCBF values in the right middle temporal gyrus and hallucinations (mainly auditory hallucination). These results suggest that chronic RIS administration dose-dependently produces a decrease of rCBF in the cerebral cortex in the manner that the low dose decreases rCBF in a few restricted cortical regions, while the high dose induces the rCBF reduction in more widespread cortical regions. The RIS-induced rCBF decrease in the cerebral cortex is considered to be attributable to a secondary inactivation in the cerebral cortex due to D 2 dopamine receptor blockade of RIS in the striatum through the cortico

  11. Frequencies and implications of discordant findings of interictal SPECT and itcal SPECT in patients with intractable epilepsy

    International Nuclear Information System (INIS)

    Lee, D. S.; Lee, S. K.; Jeong, J. K.; Lee, M. C.; Ko, C. S.

    1997-01-01

    Interictal SPECT could be used at best as a reference image to ictal SPECT, and cause sometimes confusion if it had given unexplained discordant findings from ictal SPECT. We investigated implications of discordant findings which occurred in 26 among 268 which found their epileptogenic zones using ictal EEG and/or operative outcome. Sensitivity of interictal SPECT was only 36%. Among these 268, 69 patients had no structural lesions on MR, 14 of whom had decreased perfusion on interictal SPECT (8 trues and 6 falses (adjacent or contralateral)). Structural lesion were found in 199 on MR, 103 of whom had decreased perfusion (89 trues and 14 falses). Among 26 having discordant cases, 10 interictal SPECT were proved wrong after operation and/or invasive EEG and the other 16 were on speculation using PET and ictal EEG. Ictal hyperperfusion was observed in 14 patients in these interictal SPECT. Six ictal studies were found postictal accompanied by contralateral propagation or not. Two patients had dual pathology, and the remaining 2 unknown. Interictal SPECT was done on the 2nd day after ictal study(24), the 3rd day (18), the 4th day(16), the 5th day (23). Four among 24 interictal studies (17%) of the 2nd day and the other 4 among 57 of 3rd to 5th day revealed ictal hyperperfusion on interictal SPECT. Six interictal studies (2.7% among 221) acquired on the indifferent day showed also ictal hyperperfusion. We could suggest that the next day is not desirable for interictal SPECT after ictal study, as ictal hyperperfusion on interictal study confounded more than postictal findings of ictal SPECT in the discrete localization than reassuring ictal study

  12. Frequencies and implications of discordant findings of interictal SPECT and itcal SPECT in patients with intractable epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D S; Lee, S K; Jeong, J K; Lee, M C; Ko, C S [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    1997-07-01

    Interictal SPECT could be used at best as a reference image to ictal SPECT, and cause sometimes confusion if it had given unexplained discordant findings from ictal SPECT. We investigated implications of discordant findings which occurred in 26 among 268 which found their epileptogenic zones using ictal EEG and/or operative outcome. Sensitivity of interictal SPECT was only 36%. Among these 268, 69 patients had no structural lesions on MR, 14 of whom had decreased perfusion on interictal SPECT (8 trues and 6 falses (adjacent or contralateral)). Structural lesion were found in 199 on MR, 103 of whom had decreased perfusion (89 trues and 14 falses). Among 26 having discordant cases, 10 interictal SPECT were proved wrong after operation and/or invasive EEG and the other 16 were on speculation using PET and ictal EEG. Ictal hyperperfusion was observed in 14 patients in these interictal SPECT. Six ictal studies were found postictal accompanied by contralateral propagation or not. Two patients had dual pathology, and the remaining 2 unknown. Interictal SPECT was done on the 2nd day after ictal study(24), the 3rd day (18), the 4th day(16), the 5th day (23). Four among 24 interictal studies (17%) of the 2nd day and the other 4 among 57 of 3rd to 5th day revealed ictal hyperperfusion on interictal SPECT. Six interictal studies (2.7% among 221) acquired on the indifferent day showed also ictal hyperperfusion. We could suggest that the next day is not desirable for interictal SPECT after ictal study, as ictal hyperperfusion on interictal study confounded more than postictal findings of ictal SPECT in the discrete localization than reassuring ictal study.

  13. Utility of QGS for 201Tl electrocardiogram-gated SPECT in cardiac function evaluations

    International Nuclear Information System (INIS)

    Shimazaki, Hiroshi; Oono, Ryuichi

    2001-01-01

    QGS (quantitative gated SPECT) was applied to 201 Tl SPECT, whose images are inferior to those of Tc SPECT, and its utility was evaluated. More specifically, the cardiac function index was calculated by QGS, and local wall motion was evaluated visually. Accuracy was assessed by comparison with left ventriculography. The subjects were 29 patients (21 males, 8 females; 6 with myocardial infarction, 18 with stenocardia, 2 with pericardial disease, 3 with other heart diseases) who had undergone myocardial scintigraphy and left ventriculography between February and May, 2000. 201 Tl (74 or 111 MBq) was administered to all patients. The resting image was obtained 10 minutes later, and the delayed image during loading was obtained 4 hours later. The conditions for acquiring the images were as follows. Two detectors were arranged at a 90-degree angle in the form of an L. The 180 degrees from 45 degrees right anterior oblique (RAO) to 45 degrees left posterior oblique (LPO) were divided into 30 sections at 6-degree intervals, and the image in each section was acquired for 60 seconds. The matrix was 64 x 64. As a cardiac function index, the left ventricular ejection function (LVEF) obtained by electrocardiogram-gated SPECT (QGS-EF) at the rest (14 cases) and the QGS-EF on the delayed images (15 cases) were compared with the LVEF determined by left ventriculography (LVG-EF). There was an excellent positive correlation between the data obtained by two methods, with a correlation coefficient of r=0.93 (y=1.04x-0.04). Most of the difference between the values fell within two standard deviations, and the error was in the clinically allowable range. There was no significant difference between the correlation coefficient at rest and during loading or between the cases that showed an obvious defect on the image and those that did not. The local wall motion of the left ventricle was visually evaluated in five stages in two directions (RAO, 30 degrees, and LAO, 60 degrees). The motion

  14. Predictive value of brain perfusion SPECT for rTMS response in pharmacoresistant depression

    International Nuclear Information System (INIS)

    Richieri, Raphaelle; Lancon, Christophe; Boyer, Laurent; Farisse, Jean; Colavolpe, Cecile; Mundler, Olivier; Guedj, Eric

    2011-01-01

    The aim of this study was to determine the predictive value of whole-brain voxel-based regional cerebral blood flow (rCBF) for repetitive transcranial magnetic stimulation (rTMS) response in patients with pharmacoresistant depression. Thirty-three right-handed patients who met DSM-IV criteria for major depressive disorder (unipolar or bipolar depression) were included before rTMS. rTMS response was defined as at least 50% reduction in the baseline Beck Depression Inventory scores. The predictive value of 99m Tc-ethyl cysteinate dimer (ECD) single photon emission computed tomography (SPECT) for rTMS response was studied before treatment by comparing rTMS responders to non-responders at voxel level using Statistical Parametric Mapping (SPM) (p 0.10). In comparison to responders, non-responders showed significant hypoperfusions (p < 0.001, uncorrected) in the left medial and bilateral superior frontal cortices (BA10), the left uncus/parahippocampal cortex (BA20/BA35) and the right thalamus. The area under the curve for the combination of SPECT clusters to predict rTMS response was 0.89 (p < 0.001). Sensitivity, specificity, positive predictive value and negative predictive value for the combination of clusters were: 94, 73, 81 and 92%, respectively. This study shows that, in pharmacoresistant depression, pretreatment rCBF of specific brain regions is a strong predictor for response to rTMS in patients with homogeneous demographic/clinical features. (orig.)

  15. Cerebral blood flow and volume in sympton-free migraineurs: A SPECT study

    International Nuclear Information System (INIS)

    Maini, C.L.; Turco, G.L.; Castellano, G.; Podio, V.; Cornaglia, G.; Liboni, W.; Chianale, G.

    1990-01-01

    Both CBF and BCV were evaluated by gamma-camera SPECT in 14 patients with classic migraine, all studied while symptom-free. Nuclear data were correlated with CT and MRI. A decreased regional CBF was observed in 13 of the 14 patients. The decreased perfusion was localized in the frontal lobe in 6 patients, the temporal lobe in one, the parietal lobe in 11 and the occipital lobe in 5 patients. The parieto-occipital cortex was involved more often than the frontal cortex; the association of hypoperfusion with parieto-occipital cortex was quite high. The right parieto-occipital regions were affected more often than the left ones. Regional CBV was increased in 8 patients. There was good topographical concordance between decreased CBF and increased CBV, but the increase of CBV was in general more evident at the periphery of the hypoperfusion. It is of interest that the only patient with a normal CBF study had a pathological CBV study. Apparently, CBF derangements are very common in symptom-free patients with classic migraine, a CBF decrease being often accompanied by a CBV increase. In these patients both CT and MRI have a lower diagnostic yield than SPECT. (orig.) [de

  16. Cerebral blood flow and volume in sympton-free migraineurs: A SPECT study

    Energy Technology Data Exchange (ETDEWEB)

    Maini, C.L. (Ancona Univ. (Italy). Chair of Nuclear Medicine); Turco, G.L.; Castellano, G.; Podio, V.; Cornaglia, G. (Turin Univ. (Italy). Chair of Nuclear Medicine); Liboni, W.; Chianale, G. (Turin Univ. (Italy). Dept. of Neurology)

    1990-11-01

    Both CBF and BCV were evaluated by gamma-camera SPECT in 14 patients with classic migraine, all studied while symptom-free. Nuclear data were correlated with CT and MRI. A decreased regional CBF was observed in 13 of the 14 patients. The decreased perfusion was localized in the frontal lobe in 6 patients, the temporal lobe in one, the parietal lobe in 11 and the occipital lobe in 5 patients. The parieto-occipital cortex was involved more often than the frontal cortex; the association of hypoperfusion with parieto-occipital cortex was quite high. The right parieto-occipital regions were affected more often than the left ones. Regional CBV was increased in 8 patients. There was good topographical concordance between decreased CBF and increased CBV, but the increase of CBV was in general more evident at the periphery of the hypoperfusion. It is of interest that the only patient with a normal CBF study had a pathological CBV study. Apparently, CBF derangements are very common in symptom-free patients with classic migraine, a CBF decrease being often accompanied by a CBV increase. In these patients both CT and MRI have a lower diagnostic yield than SPECT. (orig.).

  17. Functional brain imaging with SPECT in normal again and dementia. Methodological, pathophysiological, and diagnostic aspects

    International Nuclear Information System (INIS)

    Waldemar, G.

    1996-03-01

    New developments in instrumentation, radiochemistry, and data analysis, particularly the introduction of 99m Tc-labeled brain-retained tracers for perfusion studies, have opened up a new era of single photon emission computed tomography (SPECT). In this review critical methodological issues relating to the SPECT instrument, the radioactive tracers, the scanning procedure, the data analysis and interpretation of data, and subject selection are discussed together with the changes in regional cerebral blood flow (rCBF) observed in normal aging. An overview is given of the topography and the pathophysiological and diagnostic significance of focal rCBF deficits in Alzheimer's disease and in other dementia disorders, in which SPECT is capable of early or preclinical disease detection. In Alzheimer's disease, the diagnostic sensitivity and specificity of focal rCBF deficits measured with SPECT and brain-retained tracers are very high, in particular when combined with medial temporal lob atrophy on CT. Together with neuropsychological testing, SPECT serves to map the topography of brain dysfunction. Thus, in the clinical setting, SPECT provides information that is supplemental to that obtained in other studies. Future applications include neuroreceptor studies and treatment studies, in which SPECT may serve as a diagnostic aid in the selection of patients and as a potential mean for monitoring treatment effects. Although positron emission tomography is the best characterized tool for addressing some of these clinical and research issues in dementia, only the less expensive and technically simpler SPECT technique will have the potential of being available as a screening diagnostic instrument in the clinical setting. It is concluded that, properly approached, functional brain imaging with SPECT represents an important tool in the diagnosis, management, and research of dementia disorders. (au) 251 refs

  18. 99mTc-GSA dynamic SPECT for regional hepatic functional reserve estimation. Assessment of quantification

    International Nuclear Information System (INIS)

    Hwang, Eui-Hyo

    1999-01-01

    The aim of this study is the assessment of the physiological implication of estimated parameters and the clinical value of this analyzing method for hepatic functional reserve estimation. After venous injection of 185 MBq of GSA, fifteen sequential sets of SPECT data were acquired for 15 minutes. First 5 sets SPECT images were analyzed by Patlak plot and hepatic GSA clearance was obtained in each matrix. The sum of hepatic GSA clearance in each matrix (total hepatic GSA clearance) was calculated as an index of whole liver functional reserve. Total hepatic GSA clearance was compared with receptor index or effective blood flow (EHBF) of whole liver which were analyzed by Direct Integral Linear Least Square Regression (DILS) method for the assessment of the physiological implications of hepatic GSA clearance. The clinical value of total hepatic GSA clearance was assessed in comparisons with the conventional hepatic function test. A very good correlations were observed between total hepatic GSA clearance and receptor index, whereas the correlations between total hepatic GSA clearance and EHBF were not significant. Significant correlations were also observed between total hepatic GSA clearance and the conventional hepatic function tests, such as choline esterase, albumin, hepaplastin test, ICG R15. (K.H.)

  19. A comparative study of simple methods to quantify cerebral blood flow with acetazolamide challenge by using iodine-123-IMP SPECT with one-point arterial sampling

    Energy Technology Data Exchange (ETDEWEB)

    Ohkubo, Masaki [Niigata Univ. (Japan). School of Health Sciences; Odano, Ikuo

    2000-04-01

    The aim of this study was to compare the accuracy of simplified methods for quantifying rCBF with acetazolamide challenge by using {sup 123}I-N-isopropyl-p-iodoamphetamine (IMP) and SPECT with one-point arterial sampling. After acetazolamide administration we quantified rCBF in 12 subjects by the following three methods: (a) the modified microsphere method, (b) the IMP-autoradiographic (ARG) method based on a two-compartment one-parameter model, and (c) the simplified method based on a two-compartment two-parameter model (functional IMP method). The accuracy of these methods was validated by comparing rCBF values with those obtained by the standard method: the super-early microsphere method with continuous withdrawal of arterial blood. On analyzing rCBF in each flow range (0-0.25, 0.25-0.5, 0.5-0.75 and more than 0.75 ml/g/min), rCBF values obtained by both methods (a) and (c) showed significant correlations (p<0.01) with those obtained by the standard method in every range, but rCBF values obtained by method (b) did not significantly correlated in the high flow range (0.5-0.75 and more than 0.75 ml/g/min). Method (c) was found to be the most accurate, even though it needs two serial SPECT scans. When requiring one SPECT scan, method (a) was considered to be superior to method (b) because of its accuracy, especially in high flow regions loaded with acetazolamide. (author)

  20. N-isopropyl-p-[I123] iodoamphetamine single photon emission computed tomography (I123-IMP SPECT) and child neurology

    International Nuclear Information System (INIS)

    Tada, Hiroshi; Morooka, Keiichi; Arimoto, Kiyoshi; Matsuo, Takiko; Takagi, Kazue; Yanagawa, Etsuko

    1992-01-01

    We studied the clinical usefulness of I 123 -IMP SPECT in 50 pediatric patients with CNS disorders, which were categorized into the convulsive disorder group (n=20), the cerebrovascular disorder group (n=10), the acute encephalopathy or CNS infection group (n=10), the metabolic or degenerative disorder group (n=6), the congenital abnormality group (n=2) and the migraine group (n=2). The findings obtained were compared with those of cranial CT. I 123 -IMP SPECT revealed abnormal findings in 45 out of the 50 patients (90%), although cranial CT showed abnormal findings in only 24 patients (48%). This difference was statistically significant (p 123 -IMP SPECT showed focal abnormalities in 26 patients (93%). Moreover in many patients with focal neurological abnormalities, we found focal abnormalities of I 123 -IMP SPECT related with neurological abnormalities of the patients. From these findings, we think I 123 -IMP SPECT might be superior to CT scanning in examining a localized lesion. It was found that in many patients with focal abnormalities in CT scanning, I 123 -IMP SPECT showed larger abnormalities in CT scanning. By using I 123 -IMP SPECT we might be able to study the blood perfusional state surrounding the abnormal area shown by CT. In 3 patients with acute cerebrovascular disorders, I 123 -IMP SPECT revealed abnormal findings 3 to 11 days earlier than cranial CT. I 123 -IMP SPECT might be useful for early recognition of the pathological state. From these experiences, we concluded that I 123 -IMP SPECT was useful for studying the pathophysiology of CNS disorders in children. (author)

  1. A clinical study in elderly patients with Parkinson's disease using MRI and SPECT

    International Nuclear Information System (INIS)

    Umahara, Takahiko; Iwamoto, Toshihiko; Takasaki, Masaru; Katsunuma, Hideyo

    1991-01-01

    Parkinson's disease (PD) is often associated with dementia in elderly patients, and sometimes PD coexists with senile dementia of the Alzheimer type (SDAT) or cerebrovascular disease (CVD) in the elderly. However, since there are few previous clinical studies on the coincidence of, or relationship between PD and CVD, the authors evaluated these aspects in 34 elderly patients with PD using MRI and SPECT. All the patients were over 70 years old. The diagnosis of PD was based on the presence of three symptons (resting tremor, cogwheel rigidity and bradikinesia) which are characteristic of PD, and the effectiveness of L-DOPA therapy. We therefore believe that patients with vascular Parkinsonism were excluded from our study. In 34 cases, 24 (71%) had MRI evidence of CVD (mainly the lacunar state). In the 10 cases who had no CVD, 2 (20%) had severe dementia and the decrease of regional cerebral blood flow (rCBF) in the temporal and parietal lobes bilaterally correlated with the SPECT findings commonly found in SDAT. A comparison of the rCBF and the results of Hasegawa's dementia score (HDS) (verbal intelligence score) was made between the patients with PD associated with CVD and the patients with PD who had no CVD and no SPECT findings which correlated with SDAT. The rCBF in the frontal lobes and the results of the HDS of the former group were significantly lower than those of the latter. As mentioned above, elderly patients with PD often had CVD, leading to dementia. We also pointed out the difficulty in making a differential diagnosis between PD with CVD and vascular Parkinsonism, and the necessity of whether or not the concept of 'mixed type Parkinsonism' should be considered. (author)

  2. The correlative analysis between CBF measured by SPECT and Chinese reading test in childhood reading disorder

    International Nuclear Information System (INIS)

    Wu Yonggang; Su Jianzhi; He Jianjun; Yang Zhiwei; Liu Guofeng

    2002-01-01

    Objective: To investigate changes of cerebral blood flow (CBF) and its association with Chinese reading skill diagnostic test (CRSDT) in childhood reading disorder (RD). Methods: In 25 RD children and 20 age-matched control subjects, the authors quantitatively determined CBF and regional cerebral blood flow (rCBF) with SPECT using the non-blood-withdrew method. The authors studied the correlation between the CBF and the total raw scores by CRSDT. Results: CBF in case group was (38.87 +- 3.77) ml·100 g -1 ·min -1 and was significantly lower than that in control group [43.65 +- 2.64) mL·100 g -1 ·min -1 (P < 0.01)]. These reduction in CBF correlated with the total raw scores by CRSDT. Conclusion: These results suggest the children with reading disorder have CBF reduction and SPECT is useful for evaluation of cerebral functioning in reading disorder children

  3. Noninvasive regional cerebral blood flow measurements at pre- and post-acetazolamide test using 99mTc-ECD

    International Nuclear Information System (INIS)

    Matsuda, Hiroshi; Nakano, Seigo; Tanaka, Masaaki.

    1996-01-01

    A technique for serial noninvasive cerebral blood flow measurements at pre- and post-acetazolamide (Diamox) test was newly developed using 99m Tc-ECD without blood sampling. Baseline mean cerebral blood flow (mCBF) was measured from graphical analysis of time activity curves for brain and aortic arch obtained from radionuclide angiography by injection of 370-555 MBq 99m Tc-ECD. The first SPECT study was performed immediately after intravenous administration of 1 g of Diamox, then baseline regional cerebral blood flow (rCBF) was calculated using Lassen's correction algorithm. Immediately after the stop of the first SPECT study, additional 555-740 MBq of 99m Tc-ECD was administered, thereafter the second SPECT study was started. Post-Diamox SPECT images were obtained by subtraction of the first baseline images from the second images. Using Lassen's algorithm, post-Diamox mCBF was estimated from the baseline mCBF, the baseline mean SPECT counts, and post-Diamox mean SPECT counts corrected for administered dose and imaging time. Post-Diamox rCBF was obtained from the post-Diamox mCBF and the post-Diamox mean SPECT counts using Lassen's algorithm. Coefficient variation was shown 2.7% and 3.5%: mCBF and rCBF, respectively in test-retest results in six patients without Diamox administration. Nine demented patients without vascular disorders showed significant mCBF increase of 35.7% on the average by post-Diamox. In conclusion, this simplified method is practically useful for measuring CBF at pre- and post-Diamox test within short period of time without any blood sample. (author)

  4. The effect of education on rCBF changes in Alzheimer's disease: a longitudinal SPECT study

    International Nuclear Information System (INIS)

    Hanyu, Haruo; Sato, Tomohiko; Shimizu, Soichiro; Kanetaka, Hidekazu; Iwamoto, Toshihiko; Koizumi, Kiyoshi

    2008-01-01

    To determine the relationship of differing levels of education on regional cerebral blood flow (rCBF) in patients with Alzheimer's disease (AD). Fifty-three patients with AD followed-up for an average of 36 months were divided into the high-educated group (HE, ≥12 years of schooling) and low-educated group (LE, 123 I]-iodoamphetamine and the SPECT data were analyzed by 3D-stereotactic surface projections. At initial evaluation, the HE group had greater rCBF deficits in the parietotemporal regions than did the LE group, even though both groups had comparable MMSE and FAST scores. When compared with initial SPECT, follow-up SPECT showed a significant rCBF reduction in widespread regions, including the frontal, parietal, temporal, and limbic lobes of the HE group, while it a significant rCBF reduction in scattered and small regions of the parietotemporal, cingulate, and occipital areas of the LE group, as the HE group had faster cognitive and functional decline than the LE group. The HE group showed lower rCBF at initial SPECT than the LE group, suggesting more advanced AD pathology. As a result, the HE group demonstrated a more extensive and severe reduction of rCBF on follow-up SPECT in association with faster cognitive and functional decline than the LE group. Our SPECT study provides stronger support for the cognitive reserve effects of education in AD. (orig.)

  5. Ejection fraction in myocardial perfusion imaging assessed with a dynamic phantom: comparison between IQ-SPECT and LEHR.

    Science.gov (United States)

    Hippeläinen, Eero; Mäkelä, Teemu; Kaasalainen, Touko; Kaleva, Erna

    2017-12-01

    Developments in single photon emission tomography instrumentation and reconstruction methods present a potential for decreasing acquisition times. One of such recent options for myocardial perfusion imaging (MPI) is IQ-SPECT. This study was motivated by the inconsistency in the reported ejection fraction (EF) and left ventricular (LV) volume results between IQ-SPECT and more conventional low-energy high-resolution (LEHR) collimation protocols. IQ-SPECT and LEHR quantitative results were compared while the equivalent number of iterations (EI) was varied. The end-diastolic (EDV) and end-systolic volumes (ESV) and the derived EF values were investigated. A dynamic heart phantom was used to produce repeatable ESVs, EDVs and EFs. Phantom performance was verified by comparing the set EF values to those measured from a gated multi-slice X-ray computed tomography (CT) scan (EF True ). The phantom with an EF setting of 45, 55, 65 and 70% was imaged with both IQ-SPECT and LEHR protocols. The data were reconstructed with different EI, and two commonly used clinical myocardium delineation software were used to evaluate the LV volumes. The CT verification showed that the phantom EF settings were repeatable and accurate with the EF True being within 1% point from the manufacture's nominal value. Depending on EI both MPI protocols can be made to produce correct EF estimates, but IQ-SPECT protocol produced on average 41 and 42% smaller EDV and ESV when compared to the phantom's volumes, while LEHR protocol underestimated volumes by 24 and 21%, respectively. The volume results were largely similar between the delineation methods used. The reconstruction parameters can greatly affect the volume estimates obtained from perfusion studies. IQ-SPECT produces systematically smaller LV volumes than the conventional LEHR MPI protocol. The volume estimates are also software dependent.

  6. SPECT and PET in cerebrovascular diseases. SPECT und PET bei cerebrovaskulaeren Erkrankungen

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, W.H. (Herzzentrum Nordrhein-Westfalen, Bad Oeynhausen (Germany). Inst. fuer Nuklearmedizin)

    1993-02-01

    Investigations using recently emerged perfusion tracers for SPECT, Tc-99m-HMPAO in particular, and studies of local glucose metabolism and oxygen utilisation with PET have deepened our knowledge of the pathophysiology in development and in the sequel of stroke. Studies of local cerebral blood flow and cerebrovascular reserve capacity are indicated in case of neurological symptoms suspected to be caused by transient ischemic attacks or in case of significant narrowing of the cerebral arteries. PET investigations of local metabolism (at the present state) are indicated in patients with incompleted stroke or with infarction and extended ischemic border zone. The differential diagnosis between multi-infarct-dementia and primarily neurodegenerative dementias is facilitated, in some individuals, by the characteristic topography of reduced flow. (orig./MG).

  7. Comparison of continuous with step and shoot acquisition in SPECT scanning

    International Nuclear Information System (INIS)

    McCarthy, L.; Cotterill, T.; Chu, J.M.G.

    1998-01-01

    Full text: Following the recent advent of continuous acquisition for performing SPECT scanning, it was decided to compare the commonly used Step and Shoot mode of acquisition with the new continuous acquisition mode. The aim of the study is to assess any difference in resolution from the resulting images acquired using the two modes of acquisition. Sequential series of studies were performed on a SPECT phantom using both modes of acquisition. Separate sets of data were collected for both high resolution parallel hole and ultra high resolution fan beam collimators. Clinical data was collected on patients undergoing routine gallium, 99m Tc-MDP bone and 99m Tc-HMPAO brain studies. Separate sequential acquisition in both modes were collected for each patient. The sequence of collection was also alternated. Reconstruction was performed utilising the same parameters for each acquisition. The reconstructed data were assessed visually by blinded observers to detect differences in resolution and image quality. No significant difference in the studies collected by either acquisition modes were detected. The time saved by continuous acquisition could be an advantage

  8. Factor analysis with a priori knowledge - application in dynamic cardiac SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Sitek, A.; Di Bella, E.V.R.; Gullberg, G.T. [Medical Imaging Research Laboratory, Department of Radiology, University of Utah, CAMT, 729 Arapeen Drive, Salt Lake City, UT 84108-1218 (United States)

    2000-09-01

    Two factor analysis of dynamic structures (FADS) methods for the extraction of time-activity curves (TACs) from cardiac dynamic SPECT data sequences were investigated. One method was based on a least squares (LS) approach which was subject to positivity constraints. The other method was the well known apex-seeking (AS) method. A post-processing step utilizing a priori information was employed to correct for the non-uniqueness of the FADS solution. These methods were used to extract {sup 99m}Tc-teboroxime TACs from computer simulations and from experimental canine and patient studies. In computer simulations, the LS and AS methods, which are completely different algorithms, yielded very similar and accurate results after application of the correction for non-uniqueness. FADS-obtained blood curves correlated well with curves derived from region of interest (ROI) measurements in the experimental studies. The results indicate that the factor analysis techniques can be used for semi-automatic estimation of activity curves derived from cardiac dynamic SPECT images, and that they can be used for separation of physiologically different regions in dynamic cardiac SPECT studies. (author)

  9. Comparison of SPECT/CT and MRI in diagnosing symptomatic lesions in ankle and foot pain patients: diagnostic performance and relation to lesion type.

    Science.gov (United States)

    Ha, Seunggyun; Hong, Sung Hwan; Paeng, Jin Chul; Lee, Dong Yeon; Cheon, Gi Jeong; Arya, Amitabh; Chung, June-Key; Lee, Dong Soo; Kang, Keon Wook

    2015-01-01

    The purpose of this study was to compare the diagnostic performance of SPECT/CT and MRI in patients with ankle and foot pain, with regard to the lesion types. Fifty consecutive patients with ankle and foot pain, who underwent 99mTc-MDP SPECT/CT and MRI, were retrospectively enrolled in this study. Symptomatic lesions were determined based on clinical examination and response to treatment. On MRI and SPECT/CT, detected lesions were classified as bone, ligament/tendon, and joint lesions. Uptake on SPECT/CT was assessed using a 4-grade system. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of SPECT/CT and MRI were evaluated in all detected lesions and each lesion type. Diagnostic value of uptake grade was analyzed using receiver-operating characteristics (ROC) curve analysis, and diagnostic performance was compared using Chi-square or McNemar tests. In overall lesions, the sensitivity, PPV and NPV of SPECT/CT for symptomatic lesions were 93%, 56%, 91%, and they were 98%, 48%, 95% for MRI. There was no significant difference between SPECT/CT and MRI. However, the specificity of SPECT/CT was significantly higher than that of MRI (48% versus 24%, P = 0.016). Uptake grade on SPECT/CT was significantly higher in symptomatic lesions (P diagnostic performance for symptomatic lesions in ankle and foot pain patients. SPECT/CT and MRI exhibit different diagnostic specificity in different lesion types. SPECT/CT may be used as a complementary imaging method to MRI for enhancing diagnostic specificity.

  10. Evaluation of bone viability in patients after girdlestone arthroplasty: comparison of bone SPECT/CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Diederichs, G.; Collettini, F.; Hamm, B.; Makowski, M.R. [Department of Radiology, Berlin (Germany); Hoppe, P.; Brenner, W. [Department of Nuclear Medicine, Berlin (Germany); Wassilew, G. [Department of Orthopedic Surgery, Berlin (Germany)

    2017-09-15

    To test the diagnostic performance of bone SPECT/CT and MRI for the evaluation of bone viability in patients after girdlestone-arthroplasty with histopathology used as gold standard. In this cross-sectional study, patients after girdlestone-arthroplasty were imaged with single-photon-emission-computed-tomography/computed-tomography (SPECT/CT) bone-scans using 99mTc-DPD. Additionally, 1.5 T MRI was performed with turbo-inversion-recovery-magnitude (TIRM), contrast-enhanced T1-fat sat (FS) and T1-mapping. All imaging was performed within 24 h prior to revision total-hip-arthroplasty in patients with a girdlestone-arthroplasty. In each patient, four standardized bone-tissue-biopsies (14 patients) were taken intraoperatively at the remaining acetabulum superior/inferior and trochanter major/minor. Histopathological evaluation of bone samples regarding bone viability was used as gold standard. A total of 56 bone-segments were analysed and classified as vital (n = 39) or nonvital (n = 17) by histopathology. Mineral/late-phase SPECT/CT showed a high sensitivity (90%) and specificity (94%) to distinguish viable and nonviable bone tissue. TIRM (sensitivity 87%, specificity 88%) and contrast-enhanced T1-FS (sensitivity 90%, specificity 88%) also achieved a high sensitivity and specificity. T1-mapping achieved the lowest values (sensitivity 82%, specificity 82%). False positive results in SPECT/CT and MRI resulted from small bone fragments close to metal artefacts. Both bone SPECT/CT and MRI allow a reliable differentiation between viable and nonviable bone tissue in patients after girdlestone arthroplasty. The findings of this study could also be relevant for the evaluation of bone viability in the context of avascular bone necrosis. (orig.)

  11. Evaluation of bone viability in patients after girdlestone arthroplasty: comparison of bone SPECT/CT and MRI

    International Nuclear Information System (INIS)

    Diederichs, G.; Collettini, F.; Hamm, B.; Makowski, M.R.; Hoppe, P.; Brenner, W.; Wassilew, G.

    2017-01-01

    To test the diagnostic performance of bone SPECT/CT and MRI for the evaluation of bone viability in patients after girdlestone-arthroplasty with histopathology used as gold standard. In this cross-sectional study, patients after girdlestone-arthroplasty were imaged with single-photon-emission-computed-tomography/computed-tomography (SPECT/CT) bone-scans using 99mTc-DPD. Additionally, 1.5 T MRI was performed with turbo-inversion-recovery-magnitude (TIRM), contrast-enhanced T1-fat sat (FS) and T1-mapping. All imaging was performed within 24 h prior to revision total-hip-arthroplasty in patients with a girdlestone-arthroplasty. In each patient, four standardized bone-tissue-biopsies (14 patients) were taken intraoperatively at the remaining acetabulum superior/inferior and trochanter major/minor. Histopathological evaluation of bone samples regarding bone viability was used as gold standard. A total of 56 bone-segments were analysed and classified as vital (n = 39) or nonvital (n = 17) by histopathology. Mineral/late-phase SPECT/CT showed a high sensitivity (90%) and specificity (94%) to distinguish viable and nonviable bone tissue. TIRM (sensitivity 87%, specificity 88%) and contrast-enhanced T1-FS (sensitivity 90%, specificity 88%) also achieved a high sensitivity and specificity. T1-mapping achieved the lowest values (sensitivity 82%, specificity 82%). False positive results in SPECT/CT and MRI resulted from small bone fragments close to metal artefacts. Both bone SPECT/CT and MRI allow a reliable differentiation between viable and nonviable bone tissue in patients after girdlestone arthroplasty. The findings of this study could also be relevant for the evaluation of bone viability in the context of avascular bone necrosis. (orig.)

  12. Can perfusion SPECT aid CTPA interpretation?

    International Nuclear Information System (INIS)

    Gradinscak, D. J.; Roach, P.; Bailey, E.; Kueh, S.

    2009-01-01

    Full text:Objective: To determine whether fusion of perfusion SPECT and CTPA improves the diagnostic accuracy of CTPA. Methods: 35 patients with suspected PE who underwent both CTPA and SPECT V/Q within 48 hours were included. Of these, the majority (n=30) had PE as determined by the V/Q SPECT scan and the others (n=5) were negative for PE. The clinical reports of CTPA were reviewed and pulmonary emboli tabulated based on anatomical location. A second radiologist, blinded to the results of the clinical read and the V/Q SPECT scan, reviewed the CTPA with and without perfusion SPECT fusion for assistance. Results: A total 57 PE were reported on the clinical reports and 60 PE identified on the blinded read. Fused CTPA/perfursion SPECT images identified a further 5 PE not identified on the clinical read (8% increase) and 2 PE not identified on the blinded read (3% increase). The additional emboli detected resulted in a change in final diagnosis from PE negative to PE positive in 2 patients (6%) compared with the clinical read and 1 patient (3%) compared with the blinded read without SPECT fusion. Conclusion: Fused CTPA-SPECT perfusion improves the sensitivity of CTPA for the detection of PE in a small number of patients. Fused data may help guide the radiologist to identify sites of PE on CTPA.

  13. Interictal rCBF SPECT, MRI and Surgical Outcome of Intractable Temporal Lobe Epilepsy

    International Nuclear Information System (INIS)

    Zeon, Seok Kil; Joo, Yang Goo; Lee, Sang Doe; Son, Eun Ik; Lee, Young Hwan

    1994-01-01

    Interictal single photon emission computed tomography of regional cerebral blood flow (rCBF SPECT) in 18 intractable temporal lobe epilepsy patients (8 male and 10 female patients: average 23.5 years old) were compared with 2.0 T magnetic resonance imaging (MRI). And surgical outcome was analysed with the findings, symptom duration and lateralization of temporal lobe. Preoperatively rCRF SPECT was done in all 18 patients with intravenous injection of 740 MRq 99 m T c-HMPAO. MRI was also done preoperatively in 13 patients. Surgical outcome was classified by Engel's outcome classification (four part classification recommended at the first Palm Desert conference). rCRF SPECT detected correctly lateralising abnormality of temporal lobe hypoperfusion in 13/ 18 (72.2%), contralateral temporal lobe hypoperfusion in 2/18 (11.1%) and showed no definite abnormality in 3/18 (16.7%). The positive predictive value of unilateral temporal lobe hypoperfusion was 87%. MRI detected correct localising abnormality in 8/13 (61.5%), such as hippocampal atrophy (7/13), asymmetric temporal horn (6/13), anterior temporal lobe atrophy (1/13), increased signal intensity from hippocampus (1/13) and calcific density (1/13), and no abnormal finding was noted in 5/13 (38.5%), There was no false positive findings and the positive predictive value of MRI was 100%, Only 2 cases showed same lateralization findings in rCBF SPECT and MRI. There was no significant correlation between symptom duration and no abnormal findings on SPECT or MRI. Surgical outcome showed class I in 15/18 (83.3%), and class II in 2/18 (11.1%). One case of no abnormal finding in both SPECT and MRI showed class III surgical outcome. No class IV surgical out.come was noted. Surgical outcome, lateralization of epileptic focus in temporal lobe and abnormal findings in rCBR SPECT or MRI were not significantly correlated.

  14. Evaluation of image reconstruction methods for 123I-MIBG-SPECT. A rank-order study

    International Nuclear Information System (INIS)

    Soederberg, Marcus; Mattsson, Soeren; Oddstig, Jenny; Uusijaervi-Lizana, Helena; Leide-Svegborn, Sigrid; Valind, Sven; Thorsson, Ola; Garpered, Sabine; Prautzsch, Tilmann; Tischenko, Oleg

    2012-01-01

    Background: There is an opportunity to improve the image quality and lesion detectability in single photon emission computed tomography (SPECT) by choosing an appropriate reconstruction method and optimal parameters for the reconstruction. Purpose: To optimize the use of the Flash 3D reconstruction algorithm in terms of equivalent iteration (EI) number (number of subsets times the number of iterations) and to compare with two recently developed reconstruction algorithms ReSPECT and orthogonal polynomial expansion on disc (OPED) for application on 123 I-metaiodobenzylguanidine (MIBG)-SPECT. Material and Methods: Eleven adult patients underwent SPECT 4 h and 14 patients 24 h after injection of approximately 200 MBq 123 I-MIBG using a Siemens Symbia T6 SPECT/CT. Images were reconstructed from raw data using the Flash 3D algorithm at eight different EI numbers. The images were ranked by three experienced nuclear medicine physicians according to their overall impression of the image quality. The obtained optimal images were then compared in one further visual comparison with images reconstructed using the ReSPECT and OPED algorithms. Results: The optimal EI number for Flash 3D was determined to be 32 for acquisition 4 h and 24 h after injection. The average rank order (best first) for the different reconstructions for acquisition after 4 h was: Flash 3D 32 > ReSPECT > Flash 3D 64 > OPED, and after 24 h: Flash 3D 16 > ReSPECT > Flash 3D 32 > OPED. A fair level of inter-observer agreement concerning optimal EI number and reconstruction algorithm was obtained, which may be explained by the different individual preferences of what is appropriate image quality. Conclusion: Using Siemens Symbia T6 SPECT/CT and specified acquisition parameters, Flash 3D 32 (4 h) and Flash 3D 16 (24 h), followed by ReSPECT, were assessed to be the preferable reconstruction algorithms in visual assessment of 123 I-MIBG images

  15. Diagnostic role of (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging for early and atypical bone metastases.

    Science.gov (United States)

    Chen, Xiao-Liang; Li, Qian; Cao, Lin; Jiang, Shi-Xi

    2014-01-01

    The bone metastasis appeared early before the bone imaging for most of the above patients. (99)Tc(m)-MDP ((99)Tc(m) marked methylene diphosphonate) bone imaging could diagnosis the bone metastasis with highly sensitivity, but with lower specificity. The aim of this study is to explore the diagnostic value of (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging for the early period atypical bone metastases. 15 to 30 mCi (99)Tc(m)-MDP was intravenously injected to the 34 malignant patients diagnosed as doubtful early bone metastases. SPECT, CT and SPECT/CT images were captured and analyzed consequently. For the patients diagnosed as early period atypical bone metastases by SPECT/CT, combining the SPECT/CT and MRI together as the SPECT/MRI integrated image. The obtained SPECT/MRI image was analyzed and compared with the pathogenic results of patients. The results indicated that 34 early period doubtful metastatic focus, including 34 SPECT positive focus, 17 focus without special changes by using CT method, 11 bone metastases focus by using SPECT/CT method, 23 doubtful bone metastases focus, 8 doubtful bone metastases focus, 14 doubtful bone metastases focus and 2 focus without clear image. Totally, SPECT/CT combined with SPECT/MRI method diagnosed 30 bone metastatic focus and 4 doubtfully metastatic focus. In conclusion, (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging shows a higher diagnostic value for the early period bone metastases, which also enhances the diagnostic accuracy rate.

  16. The significance of the bone single photon emission computed tomography (SPECT) for lumbar spondylolysis in adolescence

    Energy Technology Data Exchange (ETDEWEB)

    Habaguchi, Tatsuya; Hashimoto, Tomoyuki; Tada, Hiroshi; Ohkoshi, Yasumitsu; Shigenobu, Keiichi; Takemitsu, Masakazu; Yamane, Shigeru [Hakodate Central General Hospital, Hokkaido (Japan)

    1999-05-01

    The usefulness of the bone SPECT was examined by the comparison with the simple radiographs and the planar and the SPECT images of the bone scintigram obtained from cases which were diagnosed as the lumbar spondylolysis. Subjects were 36 patients (male: 26, female: 10, age: from 7 to 19 years, mean age: 15.6 years). The have had the sports experience and complained of low back pain for more than two months with no lower limb pain. The bone SPECT was more useful in the early detection of the lumbar spondylolysis in adolescence than the planar examination. It was also usefulness in the planning of the treatment including the restriction of exercise and the treatment by the equipments. It seemed to be useful to observe the progress of the treatment in the conservative treatment. But the bone SPECT is expensive, and the problems of the exposure and the equipments remain unsolved. So the bone SPECT should be performed restricting the cases under the consideration of ages, the sports experience and the duration of the lower back pain. (K.H.)

  17. The significance of the bone single photon emission computed tomography (SPECT) for lumbar spondylolysis in adolescence

    International Nuclear Information System (INIS)

    Habaguchi, Tatsuya; Hashimoto, Tomoyuki; Tada, Hiroshi; Ohkoshi, Yasumitsu; Shigenobu, Keiichi; Takemitsu, Masakazu; Yamane, Shigeru

    1999-01-01

    The usefulness of the bone SPECT was examined by the comparison with the simple radiographs and the planar and the SPECT images of the bone scintigram obtained from cases which were diagnosed as the lumbar spondylolysis. Subjects were 36 patients (male: 26, female: 10, age: from 7 to 19 years, mean age: 15.6 years). The have had the sports experience and complained of low back pain for more than two months with no lower limb pain. The bone SPECT was more useful in the early detection of the lumbar spondylolysis in adolescence than the planar examination. It was also usefulness in the planning of the treatment including the restriction of exercise and the treatment by the equipments. It seemed to be useful to observe the progress of the treatment in the conservative treatment. But the bone SPECT is expensive, and the problems of the exposure and the equipments remain unsolved. So the bone SPECT should be performed restricting the cases under the consideration of ages, the sports experience and the duration of the lower back pain. (K.H.)

  18. Blood-brain barrier dysfunction following traumatic brain injury: correlation of K(trans) (DCE-MRI) and SUVR (99mTc-DTPA SPECT) but not serum S100B.

    Science.gov (United States)

    Winter, Craig; Bell, Christopher; Whyte, Timothy; Cardinal, John; Macfarlane, David; Rose, Stephen

    2015-07-01

    Damage to the blood-brain barrier (BBB) is an important secondary mechanism that occurs following traumatic brain injury (TBI) and may provide a potential therapeutic target to improve patient outcome. For such a progress to be realised, an accurate assessment of BBB compromise needs to be established. Fourteen patients with TBI were prospectively recruited. Post-traumatic BBB dysfunction was assessed using dynamic contrast-enhanced MRI (DCE-MRI), single-photon emission computerised tomography (SPECT) and serum S100B levels. A statistically significant correlation between standardised uptake value ratio (SUVR) calculated from 99mTc-DTPA SPECT and K(trans) (a volume transfer constant) from DCE-MRI was found for those eight patients who had concurrent scans. The positive correlation persisted when the data were corrected for patient age, number of days following trauma and both parameters combined. We found no statistically significant correlation between either of the imaging modalities and concurrent serum S100B levels. The correlation of SPECT with DCE-MRI suggests that either scan may be used to assess post-traumatic BBB damage. We could not support serum S100B to be an accurate measure of BBB damage when sampled a number of days following injury but the small number of patients, the heterogeneity in TBI patients and the delay following injury makes any firm conclusions regarding S100B and BBB difficult.

  19. Single-photon emission computed tomography (SPECT) in oediatric migraine

    International Nuclear Information System (INIS)

    Battistella, P.A.; Pitassi, I.; Ruffilli, R.; Boniver, C.; Suppiej, A.; Casara, G.

    1989-01-01

    Cerebral blood flow in pediatric patients suffering from different types of migraine is analyzed by SPECT with 99m Tc HM-PAO, during the pain free intervals. The results indicate that such studies may give further information toward the understanding of common and classic forms of migraine and the difference in the CBF patterns of these forms support the hypothesis of a possible different pathogenesis. (H.W.). 13 refs.; 1 tab

  20. Sequential SPECT/CT imaging starting with stress SPECT in patients with left bundle branch block suspected for coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Engbers, Elsemiek M.; Mouden, Mohamed [Isala, Department of Cardiology, Zwolle (Netherlands); Isala, Department of Nuclear Medicine, Zwolle (Netherlands); Timmer, Jorik R.; Ottervanger, Jan Paul [Isala, Department of Cardiology, Zwolle (Netherlands); Knollema, Siert; Jager, Pieter L. [Isala, Department of Nuclear Medicine, Zwolle (Netherlands)

    2017-01-15

    To investigate the impact of left bundle branch block (LBBB) on sequential single photon emission computed tomography (SPECT)/ CT imaging starting with stress-first SPECT. Consecutive symptomatic low- to intermediate-risk patients without a history of coronary artery disease (CAD) referred for SPECT/CT were included from an observational registry. If stress SPECT was abnormal, additional rest SPECT and, if feasible, coronary CT angiography (CCTA) were acquired. Of the 5,018 patients, 218 (4.3 %) demonstrated LBBB. Patients with LBBB were slightly older than patients without LBBB (65±12 vs. 61±11 years, p<0.001). Stress SPECT was more frequently abnormal in patients with LBBB (82 % vs. 46 %, p<0.001). After reviewing stress and rest images, SPECT was normal in 43 % of the patients with LBBB, compared to 77 % of the patients without LBBB (p<0.001). Sixty-four of the 124 patients with LBBB and abnormal stress-rest SPECT underwent CCTA (52 %), which could exclude obstructive CAD in 46 of the patients (72 %). Sequential SPECT/CT imaging starting with stress SPECT is not the optimal imaging protocol in patients with LBBB, as the majority of these patients have potentially false-positive stress SPECT. First-line testing using CCTA may be more appropriate in low- to intermediate-risk patients with LBBB. (orig.)